WorldWideScience

Sample records for prepared file consisting

  1. Comparison of working length control consistency between hand K-files and Mtwo NiTi rotary system.

    Science.gov (United States)

    Krajczár, Károly; Varga, Enikő; Marada, Gyula; Jeges, Sára; Tóth, Vilmos

    2016-04-01

    The purpose of this study was to investigate the consistency of working length control between hand instrumentation in comparison to engine driven Mtwo nickel-titanium rotary files. Forty extracted maxillary molars were selected and divided onto two parallel groups. The working lengths of the mesiobuccal root canals were estimated. The teeth were fixed in a phantom head. The root canal preparation was carried out group 1 (n=20) with hand K-files, (VDW, Munich, Germany) and group 2 (n=20) with Mtwo instruments (VDW, Munich, Germany). Vestibulo-oral and mesio-distal directional x-ray images were taken before the preparation with #10 K-file, inserted into the mesiobuccal root canal to the working length, and after preparation with #25, #30 and #40 files. Working lenght changes were detected with measurements between the radiological apex and the instrument tips. In the Mtwo group a difference in the working competency (protary files. Mtwo NiTi rotary file did therefore proved to be more accurate in comparison to the conventional hand instrumentation. Working length, Mtwo, nickel-titanium, hand preparation, engine driven preparation.

  2. Nuclear structure data file. A manual for preparation of data sets

    International Nuclear Information System (INIS)

    Ewbank, W.B.; Schmorak, M.R.; Bertrand, F.E.; Feliciano, M.; Horen, D.J.

    1975-06-01

    The Nuclear Data Project at ORNL is building a computer-based file of nuclear structure data, which is intended for use by both basic and applied users. For every nucleus, the Nuclear Structure Data File contains evaluated nuclear structure information. This manual describes a standard input format for nuclear structure data. The format is sufficiently structured that bulk data can be entered efficiently. At the same time, the structure is open-ended and can accommodate most measured or deduced quantities that yield nuclear structure information. Computer programs have been developed at the Data Project to perform consistency checking and routine calculations. Programs are also used for preparing level scheme drawings. (U.S.)

  3. Scanning electron microscopy investigation of canal cleaning after canal preparation with nickel titanium files

    Directory of Open Access Journals (Sweden)

    Živković Slavoljub

    2010-01-01

    Full Text Available Introduction. Root canal preparation is the most important phase of endodontic procedure and it consists of adequate canal space cleaning and shaping. In recent years, rotary instruments and techniques have gained importance because of the great efficacy, speed and safety of the preparation procedure. Objective. The aim of this research was to investigate the influence of different NiTi files on the canal wall cleaning quality, residual dentine debris and smear layer. Methods. The research was conducted on extracted human teeth in vitro conditions. Teeth were divided in 7 main groups depending on the kind of instruments used for root canal preparation: ProTaper, GT, ProFile, K-3, FlexMaster, hand ProTaper and hand GT. Root canal preparation was accomplished by crown-down technique. Prepared samples were assessed on scanning electron microscopy JEOL, JSM-6460 LV. The evaluation of dentine debris was done with 500x magnification, and the evaluation of smear layer with 1,000 times magnification. Quantitive assessment of dentine debris and smear layer was done according to the criteria of Hulsmann. Results. The least amount of debris and smear layer has been found in canals shaped with ProFile instruments, and the largest amount in canals shaped with FlexMaster instruments. Canal cleaning efficacy of hand GT and ProTaper files has been similar to cleaning efficacy of rotary NiTi files. Statistic analysis has shown a significant difference in amount of dentine debris and smear layer on the canal walls between sample groups shaped with different instruments. Conclusion. Completely clean canals have not been found in any tested group of instruments. The largest amount of debris and smear layer has been found in the apical third of all canals. The design and the type of endodontic instruments influence the efficacy of the canal cleaning.

  4. A novel platform for in vitro analysis of torque, forces, and three-dimensional file displacements during root canal preparations: application to ProTaper rotary files.

    Science.gov (United States)

    Diop, Amadou; Maurel, Nathalie; Oiknine, Michel; Patoor, Etienne; Machtou, Pierre

    2009-04-01

    We proposed a new testing setup and in vitro experimental procedure allowing the analysis of the forces, torque, and file displacements during the preparation of root canals using nickel-titanium rotary endodontic files. We applied it to the preparation of 20 fresh frozen cadaveric teeth using ProTaper files (Dentsply Maillefer, Ballaigues, Switzerland), according to a clinically used sequence. During the preparations, a clinical hand motion was performed by an endodontist, and we measured the applied torque around the file axis and also the involved three-dimensional forces and 3-dimensional file displacements. Such a biomechanical procedure is useful to better understand the working conditions of the files in terms of loads and displacements. It could be used to analyze the effects of various mechanical and geometric parameters on the files' behavior and to get data for modelling purposes. Finally, it could contribute to studies aiming to improve files design in order to reduce the risks of file fractures.

  5. Chemomechanical preparation by hand instrumentation and by Mtwo engine-driven rotary files, an ex vivo study.

    Science.gov (United States)

    Krajczár, Károly; Tigyi, Zoltán; Papp, Viktória; Marada, Gyula; Sára, Jeges; Tóth, Vilmos

    2012-07-01

    To compare the disinfecting efficacy of the sodium hypochlorite irrigation by root canal preparation with stainless steel hand files, taper 0.02 and nickel-titanium Mtwo files with taper 0.04-0.06. 40 extracted human teeth were sterilized, and then inoculated with Enterococcus faecalis (ATCC 29212). After 6 day incubation time the root canals were prepared by hand with K-files (n=20) and by engine-driven Mtwo files (VDW, Munich, Germany) (n=20). Irrigation was carried out with 2.5% NaOCl in both cases. Samples were taken and determined in colony forming units (CFU) from the root canals before and after the preparation with instruments #25 and #35. Significant reduction in bacterial count was determined after filing at both groups. The number of bacteria kept on decreasing with the extension of apical preparation diameter. There was no significant difference between the preparation sizes in the bacterial counts after hand or engine-driven instrumentation at the same apical size. Statistical analysis was carried out with Mann-Whitney test, paired t-test and independent sample t-test. Significant reduction in CFU was achieved after the root canal preparation completed with 2.5% NaOCl irrigation, both with stainless steel hand or nickel-titanium rotary files. The root canal remained slightly infected after chemo mechanical preparation in both groups. Key words:Chemomechanical preparation, root canal disinfection, nickel-titanium, conicity, greater taper, apical size.

  6. 76 FR 22611 - Specified Tax Return Preparers Required To File Individual Income Tax Returns Using Magnetic...

    Science.gov (United States)

    2011-04-22

    ... Specified Tax Return Preparers Required To File Individual Income Tax Returns Using Magnetic Media... Register on Wednesday, March 30, 2011 (76 FR 17521) providing guidance to specified tax return preparers who prepare and file individual income tax returns using magnetic media pursuant to section 6011(e)(3...

  7. Incidence of Apical Crack Initiation during Canal Preparation using Hand Stainless Steel (K-File) and Hand NiTi (Protaper) Files.

    Science.gov (United States)

    Soni, Dileep; Raisingani, Deepak; Mathur, Rachit; Madan, Nidha; Visnoi, Suchita

    2016-01-01

    To evaluate the incidence of apical crack initiation during canal preparation with stainless steel K-files and hand protaper files (in vitro study). Sixty extracted mandibular premo-lar teeth are randomly selected and embedded in an acrylic tube filled with autopolymerizing resin. A baseline image of the apical surface of each specimen was recorded under a digital microscope (80×). The cervical and middle thirds of all samples were flared with #2 and #1 Gates-Glidden (GG) drills, and a second image was recorded. The teeth were randomly divided into four groups of 15 teeth each according to the file type (hand K-file and hand-protaper) and working length (WL) (instrumented at WL and 1 mm less than WL). Final image after dye penetration and photomicrograph of the apical root surface were digitally recorded. Maximum numbers of cracks were observed with hand protaper files compared with hand K-file at the WL and 1 mm short of WL. Chi-square testing revealed a highly significant effect of WL on crack formation at WL and 1 mm short of WL (p = 0.000). Minimum numbers of cracks at WL and 1 mm short of WL were observed with hand K-file and maximum with hand protaper files. Soni D, Raisingani D, Mathur R, Madan N, Visnoi S. Incidence of Apical Crack Initiation during Canal Preparation using Hand Stainless Steel (K-File) and Hand NiTi (Protaper) Files. Int J Clin Pediatr Dent 2016;9(4):303-307.

  8. Evaluation of canal transportation after preparation with Reciproc single-file systems with or without glide path files.

    Science.gov (United States)

    Aydin, Ugur; Karataslioglu, Emrah

    2017-01-01

    Canal transportation is a common sequel caused by rotary instruments. The purpose of the present study is to evaluate the degree of transportation after the use of Reciproc single-file instruments with or without glide path files. Thirty resin blocks with L-shaped canals were divided into three groups ( n = 10). Group 1 - canals were prepared with Reciproc-25 file. Group 2 - glide path file-G1 was used before Reciproc. Group 3 - glide path files-G1 and G2 were used before Reciproc. Pre- and post-instrumentation images were superimposed under microscope, and resin removed from the inner and outer surfaces of the root canal was calculated throughout 10 points. Statistical analysis was performed with Kruskal-Wallis test and post hoc Dunn test. For coronal and middle one-thirds, there was no significant difference among groups ( P > 0.05). For apical section, transportation of Group 1 was significantly higher than other groups ( P files before Reciproc single-file system reduced the degree of apical canal transportation.

  9. [The use of ultrasonic files in canal preparation].

    Science.gov (United States)

    Calas, P; Terrie, B

    1990-01-01

    The continuous high volume of irrigating solution delivered by the ultrasonic system facilitates the root canal debridement. An excellent cleaning of dentin wall is obtained even on surfaces unreached by the mechanical instrumentation. In order to obtain an efficacious preparation, the use of ultrasonic files were combined with instrumentation. This new technique is described in this article.

  10. elPrep: High-Performance Preparation of Sequence Alignment/Map Files for Variant Calling.

    Directory of Open Access Journals (Sweden)

    Charlotte Herzeel

    Full Text Available elPrep is a high-performance tool for preparing sequence alignment/map files for variant calling in sequencing pipelines. It can be used as a replacement for SAMtools and Picard for preparation steps such as filtering, sorting, marking duplicates, reordering contigs, and so on, while producing identical results. What sets elPrep apart is its software architecture that allows executing preparation pipelines by making only a single pass through the data, no matter how many preparation steps are used in the pipeline. elPrep is designed as a multithreaded application that runs entirely in memory, avoids repeated file I/O, and merges the computation of several preparation steps to significantly speed up the execution time. For example, for a preparation pipeline of five steps on a whole-exome BAM file (NA12878, we reduce the execution time from about 1:40 hours, when using a combination of SAMtools and Picard, to about 15 minutes when using elPrep, while utilising the same server resources, here 48 threads and 23GB of RAM. For the same pipeline on whole-genome data (NA12878, elPrep reduces the runtime from 24 hours to less than 5 hours. As a typical clinical study may contain sequencing data for hundreds of patients, elPrep can remove several hundreds of hours of computing time, and thus substantially reduce analysis time and cost.

  11. Effect of Patency File on Transportation and Curve Straightening in Canal Preparation with ProTaper System.

    Science.gov (United States)

    Hasheminia, Seyed Mohsen; Farhadi, Nastaran; Shokraneh, Ali

    2013-01-01

    The aim of this ex vivo study was to evaluate the effect of using a patency file on apical transportation and curve straightening during canal instrumentation with the ProTaper rotary system. Seventy permanent mandibular first molars with mesiobuccal canals, measuring 18-23 mm in length and with a 25-40° curvature (according to the Schneider method), were selected. The working lengths were determined and the teeth were mounted and divided into two experimental groups: (A) prepared by the ProTaper system without using a patency file (n = 35) and (B) prepared by the ProTaper system using a patency file (n = 35). Radiographs taken before and after the preparation were imported into Photoshop software and the apical transportation, and curve straightening were measured. Data were analyzed using independent t-test. Partial correlation analysis was performed to evaluate the relationship between the initial curvature, transportation, and curve straightening (α = 0.05). Using a patency file during canal preparation significantly decreased both apical transportation and curve straightening (P system.

  12. 27 CFR 70.414 - Preparation and filing of claims.

    Science.gov (United States)

    2010-04-01

    ... Spirits, Wines, and Beer § 70.414 Preparation and filing of claims. (a) Distilled spirits at distilled.... (d) Wine spirits and wine at bonded wine cellar. Procedural instructions in respect of claims for: (1) Remission of tax on wine spirits lost on the premises of a bonded wine cellar or in transit thereto, (2...

  13. Apical extrusion of debris during the preparation of oval root canals: a comparative study between a full-sequence SAF system and a rotary file system supplemented by XP-endo finisher file.

    Science.gov (United States)

    Kfir, Anda; Moza-Levi, Rotem; Herteanu, Moran; Weissman, Amir; Wigler, Ronald

    2018-03-01

    The purpose of this study was to assess the amount of apically extruded debris during the preparation of oval canals with either a rotary file system supplemented by the XP-endo Finisher file or a full-sequence self-adjusting file (SAF) system. Sixty mandibular incisors were randomly assigned to two groups: group A: stage 1-glide path preparation with Pre-SAF instruments. Stage 2-cleaning and shaping with SAF. Group B: stage 1-glide path preparation with ProGlider file. Stage 2-cleaning and shaping with ProTaper Next system. Stage 3-Final cleaning with XP-endo Finisher file. The debris extruded during each of the stages was collected, and the debris weights were compared between the groups and between the stages within the groups using t tests with a significance level set at P file followed by XP-endo Finisher file extruded significantly more debris than a full-sequence SAF system. Each stage, in either procedure, had its own contribution to the extrusion of debris. Final preparation with XP-endo Finisher file contributes to the total amount of extruded debris, but the clinical relevance of the relative difference in the amount of apically extruded debris remains unclear.

  14. Effect of repetitive pecking at working length for glide path preparation using G-file

    Directory of Open Access Journals (Sweden)

    Jung-Hong Ha

    2015-05-01

    Full Text Available Objectives Glide path preparation is recommended to reduce torsional failure of nickel-titanium (NiTi rotary instruments and to prevent root canal transportation. This study evaluated whether the repetitive insertions of G-files to the working length maintain the apical size as well as provide sufficient lumen as a glide path for subsequent instrumentation. Materials and Methods The G-file system (Micro-Mega composed of G1 and G2 files for glide path preparation was used with the J-shaped, simulated resin canals. After inserting a G1 file twice, a G2 file was inserted to the working length 1, 4, 7, or 10 times for four each experimental group, respectively (n = 10. Then the canals were cleaned by copious irrigation, and lubricated with a separating gel medium. Canal replicas were made using silicone impression material, and the diameter of the replicas was measured at working length (D0 and 1 mm level (D1 under a scanning electron microscope. Data was analysed by one-way ANOVA and post-hoc tests (p = 0.05. Results The diameter at D0 level did not show any significant difference between the 1, 2, 4, and 10 times of repetitive pecking insertions of G2 files at working length. However, 10 times of pecking motion with G2 file resulted in significantly larger canal diameter at D1 (p < 0.05. Conclusions Under the limitations of this study, the repetitive insertion of a G2 file up to 10 times at working length created an adequate lumen for subsequent apical shaping with other rotary files bigger than International Organization for Standardization (ISO size 20, without apical transportation at D0 level.

  15. Influence of apical enlargement and complementary canal preparation with the Self-Adjusting File on endotoxin reduction in retreatment cases.

    Science.gov (United States)

    Silva, E J N L; Ferreira, V M; Silva, C C; Herrera, D R; De-Deus, G; Gomes, B P

    2017-07-01

    To compare the effectiveness of large apical preparations and complementary canal preparation with the Self-Adjusting File (SAF) in removing endotoxins from the root canal of teeth with apical periodontitis. Ten single-rooted and single-canaled teeth with post-treatment apical periodontitis were selected. Endotoxin samples were taken after removal of the root filling (S1), after chemomechanical preparation (CMP) using 2.5% NaOCl and an R25 file (S2), after CMP using 2.5% NaOCl and an R40 file (S3) and after complementary CMP using the SAF system (S4). Limulus amebocyte lysate (LAL) was used to measure endotoxin levels. The Friedman and Wilcoxon tests were used to compare endotoxin levels at each clinical intervention (P file was able to significantly reduce endotoxin levels (P file (P  0.05) following the use of the R40 instrument. Apical enlargement protocols were effective in significantly reducing endotoxin levels. Complementary preparation with the SAF system failed to eliminate residual endotoxin contents beyond those obtained with the R40 instrument. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  16. Evaluation of the efficacy of rotary vs. hand files in root canal preparation of primary teeth in vitro using CBCT.

    Science.gov (United States)

    Musale, P K; Mujawar, S A V

    2014-04-01

    This in vitro study aimed to evaluate the efficacy of rotary ProFile, ProTaper, Hero Shaper and K-files in shaping ability, cleaning efficacy, preparation time and instrument distortion in primary molars. Sixty extracted primary mandibular second molars were divided into four equal groups: Group I K-file, Group II ProFile, Group III ProTaper file and Group IV Hero Shaper file. The shaping ability was determined by comparing pre- and post-instrumentation CBCT scans and data analysed with SPSS program using the Chi-square test. Cleaning efficacy was evaluated by the degree of India ink removal from the canal walls under stereomicroscopy. Instrumentation times were calculated for each tooth and instrument distortion was visually checked and duly noted. The cleaning efficacy and instrumentation time were determined using ANOVA with Tukey's correction. Instrument distortion was analysed using Chi-square test. The canal taper was significantly more conical for rotary files as compared to K-files with Chi-square test (p < 0.05). Cleaning efficacy of rotary files with average scores (Groups II- 0.68, III- 0.48 and IV- 0.58) was significantly better than K-files (Group I- 0.93) (p < 0.05). Mean instrumentation time with K-file (20.7 min) was significantly higher than rotary files (Groups II 8.9, III 5.6, and IV 8.1 min) (p < 0.05). Instrument distortion was observed in Group I (4.3%), while none of the rotary files were distorted. Rotary files prepared more conical canals in primary teeth than manual instruments. Reduced preparation time with rotary files enhances patient cooperation especially in young children.

  17. Comparative evaluation of dentinal defects induced by hand files, hyflex, protaper next and one shape during canal preparation: A stereomicroscopic study

    Directory of Open Access Journals (Sweden)

    Ekta Garg

    2017-01-01

    Full Text Available Aim: This study aims to evaluate and compare the incidence of dentinal defects induced by Hand Files, HyFlex CM, ProTaper Next (PTN, and One Shape during canal preparation. Materials and Methods: One hundred and fifty extracted mandibular premolar teeth with single root canal were selected. Specimens were then divided into five groups with thirty specimens each. Group I: Specimens were prepared with hand instruments. Group II: Specimens were prepared with HyFlex CM rotary files (Coltene using a crown-down technique according to the manufacturer's instructions. Group III: Specimens were prepared with PTN rotary files (Dentsply using a crown-down technique according to the manufacturer's instructions. Group IV: Specimens were prepared with One Shape Single file rotary system (MicroMega using a crown-down technique according to the manufacturer's instructions. Group V: Specimens were used as a control and left unprepared. All roots were cut horizontally at 3, 6, and 9 mm from the apex. Sections were then viewed under stereomicroscope and dentinal defects were registered as “no defect,” “fracture,” and “other defects.” Statistical Analysis: Results of the study were subjected to Chi-square test. Results: Results were expressed as the number and percentage of defected, partially defected and roots with no defects in each groups. Conclusion: Hand files and One Shape file system caused less root defects compared to PTN and HyFlex file systems.

  18. Preservation of root canal anatomy using self-adjusting file instrumentation with glide path prepared by 20/0.02 hand files versus 20/0.04 rotary files

    Science.gov (United States)

    Jain, Niharika; Pawar, Ajinkya M.; Ukey, Piyush D.; Jain, Prashant K.; Thakur, Bhagyashree; Gupta, Abhishek

    2017-01-01

    Objectives: To compare the relative axis modification and canal concentricity after glide path preparation with 20/0.02 hand K-file (NITIFLEX®) and 20/0.04 rotary file (HyFlex™ CM) with subsequent instrumentation with 1.5 mm self-adjusting file (SAF). Materials and Methods: One hundred and twenty ISO 15, 0.02 taper, Endo Training Blocks (Dentsply Maillefer, Ballaigues, Switzerland) were acquired and randomly divided into following two groups (n = 60): group 1, establishing glide path till 20/0.02 hand K-file (NITIFLEX®) followed by instrumentation with 1.5 mm SAF; and Group 2, establishing glide path till 20/0.04 rotary file (HyFlex™ CM) followed by instrumentation with 1.5 mm SAF. Pre- and post-instrumentation digital images were processed with MATLAB R 2013 software to identify the central axis, and then superimposed using digital imaging software (Picasa 3.0 software, Google Inc., California, USA) taking five landmarks as reference points. Student's t-test for pairwise comparisons was applied with the level of significance set at 0.05. Results: Training blocks instrumented with 20/0.04 rotary file and SAF were associated less deviation in canal axis (at all the five marked points), representing better canal concentricity compared to those, in which glide path was established by 20/0.02 hand K-files followed by SAF instrumentation. Conclusion: Canal geometry is better maintained after SAF instrumentation with a prior glide path established with 20/0.04 rotary file. PMID:28855752

  19. [Continuous observation of canal aberrations in S-shaped simulated root canal prepared by hand-used ProTaper files].

    Science.gov (United States)

    Xia, Ling-yun; Leng, Wei-dong; Mao, Min; Yang, Guo-biao; Xiang, Yong-gang; Chen, Xin-mei

    2009-08-01

    To observe the formation of canal aberrations in S-shaped root canals prepared by every file of hand-used ProTaper. Fifteen S-shaped simulated resin root canals were selected. Each root canal was prepared by every file of hand-used ProTaper following the manufacturer instruction. The images of canals prepared by S1, S2, F1, F2 and F3 were taken and stored, which were divided into group S1, S2, F1, F2 and F3. One image of canal unprepared was superposed with the images of the same root canal in these five groups respectively to observe the types and number of canal aberrations, which included unprepared area, danger zone, ledge, elbow, zip and perforation. SPSS12.0 software pakage was used for Fisher's exact probabilities in 2x2 table. Unprepared area decreased following preparation by every file of ProTaper, but it still existed when the canal preparation was finished. The incidence of danger zone, elbow and zip in group F1 was 15/15, 11/15, 4/15, respectively, which was significantly higher than that in group S2(2/15,0,0) (PProTaper.The presence of unprepared area suggests that it is essential to rinse canal abundantly during complicated canal preparation and canal antisepsis after preparation.

  20. 75 FR 76940 - Specified Tax Return Preparers Required To File Individual Income Tax Returns Using Magnetic...

    Science.gov (United States)

    2010-12-10

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service 26 CFR Parts 1 and 301 [REG-100194-10] RIN 1545-BJ52 Specified Tax Return Preparers Required To File Individual Income Tax Returns Using Magnetic... for ``specified tax return prepares,''. FOR FURTHER INFORMATION CONTACT: Keith L. Brau at (202) 622...

  1. In vitro investigation of the cleaning efficacy, shaping ability, preparation time and file deformation of continuous rotary, reciprocating rotary and manual instrumentations in primary molars

    Directory of Open Access Journals (Sweden)

    Nahid Ramazani

    2016-03-01

    Full Text Available Background. Efficient canal preparation is the key to successful root canal treatment. This study aimed to assess the cleaning and shaping ability, preparation time and file deformation of rotary, reciprocating and manual instrumentation in canal preparation of primary molars. Methods. The mesiobuccal canals of 64 extracted primary mandibular second molars were injected with India ink. The samples were randomly divided into one control and three experimental groups. Experimental groups were instrumented with K-file, Mtwo in continuous rotation and Reciproc in reciprocating motion, respectively. The control group received no treatment. The files were discarded after four applications. Shaping ability was evaluated using CBCT. After clearing, ink removal was scored. Preparation time and file fracture or deformation was also recorded. Data were analyzed with SPSS 19 using chi-squared, Fisher’s exact test, Kruskal-Wallis and post hoc tests at a significance level of 0.05. Results. Considering cleanliness, at coronal third Reciproc was better than K-file (P < 0.001, but not more effective than Mtwo (P = 0.080. Furthermore, Mtwo leaved the canal cleaner than K-file (P = 0.001. In the middle third, only Reciproc exhibited better cleaning efficacy than K-file (P = 0.005. In the apical third, no difference was detected between the groups (P = 0.794. Regarding shaping ability, no differences were found between Reciproc and Mtwo (P = 1.00. Meanwhile, both displayed better shaping efficacy than K-file (P < 0.05. Between each two groups, there were differences in preparation time (P < 0.05, with Reciproc being the fastest. No file failure occurred. Conclusion. Fast and sufficient cleaning and shaping could be achieved with Mtwo and especially with Reciproc.

  2. In vitro investigation of the cleaning efficacy, shaping ability, preparation time and file deformation of continuous rotary, reciprocating rotary and manual instrumentations in primary molars.

    Science.gov (United States)

    Ramazani, Nahid; Mohammadi, Abbas; Amirabadi, Foroogh; Ramazani, Mohsen; Ehsani, Farzane

    2016-01-01

    Background. Efficient canal preparation is the key to successful root canal treatment. This study aimed to assess the cleaning and shaping ability, preparation time and file deformation of rotary, reciprocating and manual instrumentation in canal preparation of primary molars. Methods. The mesiobuccal canals of 64 extracted primary mandibular second molars were injected with India ink. The samples were randomly divided into one control and three experimental groups. Experimental groups were instrumented with K-file, Mtwo in continuous rotation and Reciproc in reciprocating motion, respectively. The control group received no treatment. The files were discarded after four applications. Shaping ability was evaluated using CBCT. After clearing, ink removal was scored. Preparation time and file fracture or deformation was also recorded. Data were analyzed with SPSS 19 using chi-squared, Fisher's exact test, Kruskal-Wallis and post hoc tests at a significance level of 0.05. Results. Considering cleanliness, at coronal third Reciproc was better than K-file (P < 0.001), but not more effective than Mtwo (P = 0.080). Furthermore, Mtwo leaved the canal cleaner than K-file (P = 0.001). In the middle third, only Reciproc exhibited better cleaning efficacy than K-file (P = 0.005). In the apical third, no difference was detected between the groups (P = 0.794). Regarding shaping ability, no differences were found between Reciproc and Mtwo (P = 1.00). Meanwhile, both displayed better shaping efficacy than K-file (P < 0.05). Between each two groups, there were differences in preparation time (P < 0.05), with Reciproc being the fastest. No file failure occurred. Conclusion. Fast and sufficient cleaning and shaping could be achieved with Mtwo and especially with Reciproc.

  3. [In vitro comparison of root canal preparation with step-back technique and GT rotary file--a nickel-titanium engine driven rotary instrument system].

    Science.gov (United States)

    Krajczár, Károly; Tóth, Vilmos; Nyárády, Zoltán; Szabó, Gyula

    2005-06-01

    The aim of the authors' study was to compare the remaining root canal wall thickness and the preparation time of root canals, prepared either with step-back technique, or with GT Rotary File, an engine driven nickel-titanium rotary instrument system. Twenty extracted molars were decoronated. Teeth were divided in two groups. In Group 1 root canals were prepared with step-back technique. In Group 2 GT Rotary File System was utilized. Preoperative vestibulo-oral X-ray pictures were taken from all teeth with radiovisiograph (RVG). The final preparations at the mesiobuccal canals (MB) were performed with size #30 and palatinal/distal canals with size #40 instruments. Postoperative RVG pictures were taken ensuring the preoperative positioning. The working time was measured in seconds during each preparation. The authors also assessed the remaining root canal wall thickness at 3, 6 and 9 mm from the radiological apex, comparing the width of the canal walls of the vestibulo-oral projections on pre- and postoperative RVG pictures both mesially and buccally. The ratios of the residual and preoperative root canal wall thickness were calculated and compared. The largest difference was found at the MB canals of the coronal and middle third level of the root, measured on the distal canal wall. The ratio of the remaining dentin wall thickness at the coronal and the middle level in the case of step-back preparation was 0.605 and 0.754, and 0.824 and 0.895 in the cases of GT files respectively. The preparation time needed for GT Rotary File System was altogether 68.7% (MB) and 52.5% (D/P canals) of corresponding step-back preparation times. The use of GT Rotary File with comparison of standard step-back method resulted in a shortened preparation time and excessive damage of the coronal part of the root canal could be avoided.

  4. Consistency Anchor Formalization and Correctness Proofs

    OpenAIRE

    Miguel, Correia; Bessani, Alysson

    2014-01-01

    This is report contains the formal proofs for the techniques for increasing the consistency of cloud storage as presented in "Bessani et al. SCFS: A Cloud-backed File System. Proc. of the 2014 USENIX Annual Technical Conference. June 2014." The consistency anchor technique allows one to increase the consistency provided by eventually consistent cloud storage services like Amazon S3. This technique has been used in the SCFS (Shared Cloud File System) cloud-backed file system for solving rea...

  5. Cone-beam Computed Tomographic Assessment of Canal Centering Ability and Transportation after Preparation with Twisted File and Bio RaCe Instrumentation.

    Directory of Open Access Journals (Sweden)

    Kiamars Honardar

    2014-08-01

    Full Text Available Use of rotary Nickel-Titanium (NiTi instruments for endodontic preparation has introduced a new era in endodontic practice, but this issue has undergone dramatic modifications in order to achieve improved shaping abilities. Cone-beam computed tomography (CBCT has made it possible to accurately evaluate geometrical changes following canal preparation. This study was carried out to compare canal centering ability and transportation of Twisted File and BioRaCe rotary systems by means of cone-beam computed tomography.Thirty root canals from freshly extracted mandibular and maxillary teeth were selected. Teeth were mounted and scanned before and after preparation by CBCT at different apical levels. Specimens were divided into 2 groups of 15. In the first group Twisted File and in the second, BioRaCe was used for canal preparation. Canal transportation and centering ability after preparation were assessed by NNT Viewer and Photoshop CS4 software. Statistical analysis was performed using t-test and two-way ANOVA.All samples showed deviations from the original axes of the canals. No significant differences were detected between the two rotary NiTi instruments for canal centering ability in all sections. Regarding canal transportation however, a significant difference was seen in the BioRaCe group at 7.5mm from the apex.Under the conditions of this in vitro study, Twisted File and BioRaCe rotary NiTi files retained original canal geometry.

  6. Influence of a glide path on apical extrusion of debris during canal preparation using single-file systems in curved canals.

    Science.gov (United States)

    Topçuoğlu, H S; Düzgün, S; Akpek, F; Topçuoğlu, G; Aktı, A

    2016-06-01

    To evaluate the effect of a glide path on the amount of apically extruded debris during canal preparation using single-file systems in curved canals. Ninety extracted mandibular molar teeth were randomly assigned to six groups (n = 15 for each group) for canal instrumentation. Endodontic access cavities were prepared in each tooth. In three of the six groups, a glide path was not created whereas a glide path was created using PathFile instruments on the mesial canals of all teeth in the remaining three groups. The mesial canals of the teeth were then instrumented with the following single-file instrument systems: WaveOne, Reciproc and OneShape. Debris extruded apically during instrumentation was collected into pre-weighed Eppendorf tubes. The tubes were then stored in an incubator at 70 °C for 5 days. The weight of the dry extruded debris was established by subtracting the pre-instrumentation and post-instrumentation weight of the Eppendorf tubes for each group. The data obtained were analysed using one-way analysis of variance (anova) and Tukey's post hoc tests. The OneShape file was associated with less debris extrusion than the Reciproc and WaveOne files when canal instrumentation was performed without a glide path (P files (P > 0.05). There was no significant difference amongst the OneShape, Reciproc and WaveOne files when a glide path was created before canal preparation in curved root canals (P > 0.05). All systems extruded significantly less debris in groups with a glide path than in groups without a glide path (P < 0.05). All instruments were associated with apical extrusion of debris. Creating a glide path prior to canal instrumentation reduced the amount of apically extruded debris in curved canals. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  7. FragIt: a tool to prepare input files for fragment based quantum chemical calculations.

    Directory of Open Access Journals (Sweden)

    Casper Steinmann

    Full Text Available Near linear scaling fragment based quantum chemical calculations are becoming increasingly popular for treating large systems with high accuracy and is an active field of research. However, it remains difficult to set up these calculations without expert knowledge. To facilitate the use of such methods, software tools need to be available to support these methods and help to set up reasonable input files which will lower the barrier of entry for usage by non-experts. Previous tools relies on specific annotations in structure files for automatic and successful fragmentation such as residues in PDB files. We present a general fragmentation methodology and accompanying tools called FragIt to help setup these calculations. FragIt uses the SMARTS language to locate chemically appropriate fragments in large structures and is applicable to fragmentation of any molecular system given suitable SMARTS patterns. We present SMARTS patterns of fragmentation for proteins, DNA and polysaccharides, specifically for D-galactopyranose for use in cyclodextrins. FragIt is used to prepare input files for the Fragment Molecular Orbital method in the GAMESS program package, but can be extended to other computational methods easily.

  8. Comparison of Alterations in the Surface Topographies of HyFlex CM and HyFlex EDM Nickel-titanium Files after Root Canal Preparation: A Three-dimensional Optical Profilometry Study.

    Science.gov (United States)

    Uslu, Gülşah; Özyürek, Taha; Yılmaz, Koray

    2018-01-01

    The aims of the present study were to examine the surface topographies of intact HyFlex CM and HyFlex EDM nickel-titanium files and to compare alterations in the surface topographies of these files after root canal preparation of severely curved canals of molar teeth. Eight HyFlex CM (25/.08) and 8 HyFlex EDM (25/.08) files were included in the present study. In total, 64 severely curved canals of molar teeth, with curvature angles ranging between 50° and 70°, were prepared with HyFlex CM and EDM (n = 32 in each group). Quantitative and qualitative analyses of the files' surface deformation were performed by using three-dimensional optical profilometry before and after root canal preparation. The data were analyzed with the Student t test at the 5% significant level by using SPSS 21.0 software. In the HyFlex EDM group, the qualitative evaluation revealed the presence of cracks and microcavities after use of the file for root canal preparation, whereas only minor surface deformation was observed in the HyFlex CM group. The average roughness, root mean square roughness, and peak to valley height values of the HyFlex EDM group were significantly higher than those of the HyFlex CM group before and after root canal preparation (P EDM group was not statistically significant (P > .5). Within the limitations of the present study, the HyFlex CM files showed significantly higher surface alterations compared with the HyFlex EDM files after the preparation of severely curved root canals. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  9. A micro-computed tomographic evaluation of dentinal microcrack alterations during root canal preparation using single-file Ni-Ti systems.

    Science.gov (United States)

    Li, Mei-Lin; Liao, Wei-Li; Cai, Hua-Xiong

    2018-01-01

    The aim of the present study was to evaluate the length of dentinal microcracks observed prior to and following root canal preparation with different single-file nickel-titanium (Ni-Ti) systems using micro-computed tomography (micro-CT) analysis. A total of 80 mesial roots of mandibular first molars presenting with type II Vertucci canal configurations were scanned at an isotropic resolution of 7.4 µm. The samples were randomly assigned into four groups (n=20 per group) according to the system used for root canal preparation, including the WaveOne (WO), OneShape (OS), Reciproc (RE) and control groups. A second micro-CT scan was conducted after the root canals were prepared with size 25 instruments. Pre- and postoperative cross-section images of the roots (n=237,760) were then screened to identify the lengths of the microcracks. The results indicated that the microcrack lengths were notably increased following root canal preparation (Pfiles. Among the single-file Ni-Ti systems, WO and RE were not observed to cause notable microcracks, while the OS system resulted in evident microcracks.

  10. Consistency between data from the ENDF/B-V dosimetry file and corresponding experimental data for some fast neutron reference spectra

    International Nuclear Information System (INIS)

    Nolthenius, H.J.; Zijp, W.L.

    1981-11-01

    Results are given of a study on the consistency between 'integral' and 'differential' cross sections data for four benchmark neutron spectra and 36 neutron reactions of importance for reactor neutron metrology. The energy dependent cross section data and their uncertainty data are obtained from the ENDF/B-V dosimetry file. The reactions have been considered with respect to the following quantities: 1. the precision of the averaged cross sections, for a specified spectrum; 2. the discrepancy between the measured and the calculated average cross section values; 3. the consistency between the measured and calculated average cross section values, described by the chi 2 -parameter. It was possible to take into account the available cross section covariance information present in the ENDF/B-V dosimetry file. Covariance information on the benchmark flux density spectra was not taken into account in this study

  11. Development of EDFSRS: evaluated data files storage and retrieval system

    International Nuclear Information System (INIS)

    Hasegawa, Akira

    1985-07-01

    EDFSRS: Evaluated Data Files Storage and Retrieval System has been developed, which is a complete service system for the evaluated nuclear data files compiled in the major three formats: ENDF/B, UKNDL and KEDAK. This system intends to give efficient loading and maintenance of evaluated nuclear data files to the data base administrators and efficient retrievals to their users not only with the easiness but with the best confidence. It can give users all of the information available in these major three formats. The system consists of more than fifteen independent programs and some 150 Mega byte data files and index files (data-base) of the loaded data. In addition it is designed to be operated in the on-line TSS (Time Sharing System) mode, so that users can get any information from their desk top terminals. This report is prepared as a reference manual of the EDFSRS. (author)

  12. 76 FR 17521 - Specified Tax Return Preparers Required To File Individual Income Tax Returns Using Magnetic Media

    Science.gov (United States)

    2011-03-30

    ... regulations reflect changes made to the law by the Worker, Homeownership, and Business Assistance Act of 2009... definition of a ``specified tax return preparer'' must electronically file Federal income tax returns that... of the Worker, Homeownership, and Business Assistance Act of 2009 (Pub. L. 111-92 (123 Stat. 2984...

  13. New Tools to Prepare ACE Cross-section Files for MCNP Analytic Test Problems

    International Nuclear Information System (INIS)

    Brown, Forrest B.

    2016-01-01

    Monte Carlo calculations using one-group cross sections, multigroup cross sections, or simple continuous energy cross sections are often used to: (1) verify production codes against known analytical solutions, (2) verify new methods and algorithms that do not involve detailed collision physics, (3) compare Monte Carlo calculation methods with deterministic methods, and (4) teach fundamentals to students. In this work we describe 2 new tools for preparing the ACE cross-section files to be used by MCNP ® for these analytic test problems, simple a ce.pl and simple a ce m g.pl.

  14. The Rucio Consistency Service

    CERN Document Server

    Serfon, Cedric; The ATLAS collaboration

    2016-01-01

    One of the biggest challenge with Large scale data management system is to ensure the consistency between the global file catalog and what is physically on all storage elements. To tackle this issue, the Rucio software which is used by the ATLAS Distributed Data Management system has been extended to automatically handle lost or unregistered files (aka Dark Data). This system automatically detects these inconsistencies and take actions like recovery or deletion of unneeded files in a central manner. In this talk, we will present this system, explain the internals and give some results.

  15. Comparison among manual instruments and PathFile and Mtwo rotary instruments to create a glide path in the root canal preparation of curved canals.

    Science.gov (United States)

    Alves, Vanessa de Oliveira; Bueno, Carlos Eduardo da Silveira; Cunha, Rodrigo Sanches; Pinheiro, Sérgio Luiz; Fontana, Carlos Eduardo; de Martin, Alexandre Sigrist

    2012-01-01

    Nickel-titanium rotary instruments reduce procedural errors and the time required to finish root canal preparation. The goal of this study was to evaluate the occurrences of apical transportation and canal aberrations produced with different instruments used to create a glide path in the preparation of curved root canals, namely manual K-files (Dentsply Maillefer, Ballaigues, Switzerland) and PathFile (Dentsply Maillefer) and Mtwo (Sweden and Martina, Padua, Italy) nickel-titanium rotary files. The mesial canals of 45 mandibular first and second molars (with curvature angles between 25° and 35°) were selected for this study. The specimens were divided randomly into 3 groups with 15 canals each, and canal preparation was performed by an endodontist using #10-15-20 K-type stainless steel manual files (group M), #13-16-19 PathFile rotary instruments (group PF), and #10-15-20 Mtwo rotary instruments (group MT). The double digital radiograph technique was used, pre- and postinstrumentation, to assess whether apical transportation and/or aberration in root canal morphology occurred. The initial and final images of the central axis of the canals were compared by superimposition through computerized analysis and with the aid of magnification. The specimens were analyzed by 3 evaluators, whose calibration was checked using the Kendall agreement test. No apical transportation or aberration in root canal morphology occurred in any of the teeth; therefore, no statistical analysis was conducted. Neither the manual instruments nor the PathFile or Mtwo rotary instruments used to create a glide path had any influence on the occurrence of apical transportation or produced any canal aberration. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  16. Comparison of canal transportation and centering ability of hand Protaper files and rotary Protaper files by using micro computed tomography

    OpenAIRE

    Amit Gandhi; Taru Gandhi

    2011-01-01

    Introduction and objective: The aim of the present study was to compare root canal preparation with rotary ProTaper files and hand ProTaper files to find a better instrumentation technique for maintaining root canal geometry with the aid of computed tomography. Material and methods: Twenty curved root canals with at least 10 degree of curvature were divided into 2 groups of 10 teeth each. In group I the canals were prepared with hand ProTaper files and in group II the canals were prepared wit...

  17. Instructions for preparation of data entry sheets for Licensee Event Report (LER) file. Revision 1. Instruction manual

    International Nuclear Information System (INIS)

    1977-07-01

    The manual provides instructions for the preparation of data entry sheets for the licensee event report (LER) file. It is a revision to an interim manual published in October 1974 in 00E-SS-001. The LER file is a computer-based data bank of information using the data entry sheets as input. These data entry sheets contain pertinent information in regard to those occurrences required to be reported to the NRC. The computer-based data bank provides a centralized source of data that may be used for qualitative assessment of the nature and extent of off-normal events in the nuclear industry and as an index of source information to which users may refer for more detail

  18. Development and validation of gui based input file generation code for relap

    International Nuclear Information System (INIS)

    Anwar, M.M.; Khan, A.A.; Chughati, I.R.; Chaudri, K.S.; Inyat, M.H.; Hayat, T.

    2009-01-01

    Reactor Excursion and Leak Analysis Program (RELAP) is a widely acceptable computer code for thermal hydraulics modeling of Nuclear Power Plants. It calculates thermal- hydraulic transients in water-cooled nuclear reactors by solving approximations to the one-dimensional, two-phase equations of hydraulics in an arbitrarily connected system of nodes. However, the preparation of input file and subsequent analysis of results in this code is a tedious task. The development of a Graphical User Interface (GUI) for preparation of the input file for RELAP-5 is done with the validation of GUI generated Input File. The GUI is developed in Microsoft Visual Studio using Visual C Sharp (C) as programming language. The Nodalization diagram is drawn graphically and the program contains various component forms along with the starting data form, which are launched for properties assignment to generate Input File Cards serving as GUI for the user. The GUI is provided with Open / Save function to store and recall the Nodalization diagram along with Components' properties. The GUI generated Input File is validated for several case studies and individual component cards are compared with the originally required format. The generated Input File of RELAP is found consistent with the requirement of RELAP. The GUI provided a useful platform for simulating complex hydrodynamic problems efficiently with RELAP. (author)

  19. Provider of Services File

    Data.gov (United States)

    U.S. Department of Health & Human Services — The POS file consists of two data files, one for CLIA labs and one for 18 other provider types. The file names are CLIA and OTHER. If downloading the file, note it...

  20. Ex Vivo Comparison of Mtwo and RaCe Rotary File Systems in Root Canal Deviation: One File Only versus the Conventional Method.

    Science.gov (United States)

    Aminsobhani, Mohsen; Razmi, Hasan; Nozari, Solmaz

    2015-07-01

    Cleaning and shaping of the root canal system is an important step in endodontic therapy. New instruments incorporate new preparation techniques that can improve the efficacy of cleaning and shaping. The aim of this study was to compare the efficacy of Mtwo and RaCe rotary file systems in straightening the canal curvature using only one file or the conventional method. Sixty mesial roots of extracted human mandibular molars were prepared by RaCe and Mtwo nickel-titanium (NiTi) rotary files using the conventional and only one rotary file methods. The working length was 18 mm and the curvatures of the root canals were between 15-45°. By superimposing x-ray images before and after the instrumentation, deviation of the canals was assessed using Adobe Photoshop CS3 software. Preparation time was recorded. Data were analyzed using three-way ANOVA and Tukey's post hoc test. There were no significant differences between RaCe and Mtwo or between the two root canal preparation methods in root canal deviation in buccolingual and mesiodistal radiographs (P>0.05). Changes of root canal curvature in >35° subgroups were significantly more than in other subgroups with smaller canal curvatures. Preparation time was shorter in one file only technique. According to the results, the two rotary systems and the two root canal preparation methods had equal efficacy in straightening the canals; but the preparation time was shorter in one file only group.

  1. Incidence of apical root cracks and apical dentinal detachments after canal preparation with hand and rotary files at different instrumentation lengths.

    Science.gov (United States)

    Liu, Rui; Kaiwar, Anjali; Shemesh, Hagay; Wesselink, Paul R; Hou, Benxiang; Wu, Min-Kai

    2013-01-01

    The aim of this study was to compare the incidence of apical root cracks and dentinal detachments after canal preparation with hand and rotary files at different instrumentation lengths. Two hundred forty mandibular incisors were mounted in resin blocks with simulated periodontal ligaments, and the apex was exposed. The root canals were instrumented with rotary and hand files, namely K3, ProTaper, and nickel-titanium Flex K files to the major apical foramen (AF), short AF, or beyond AF. Digital images of the apical surface of every tooth were taken during the apical enlargement at each file change. Development of dentinal defects was determined by comparing these images with the baseline image. Multinomial logistic regression test was performed to identify influencing factors. Apical crack developed in 1 of 80 teeth (1.3%) with hand files and 31 of 160 teeth (19.4%) with rotary files. Apical dentinal detachment developed in 2 of 80 teeth (2.5%) with hand files and 35 of 160 teeth (21.9%) with rotary files. Instrumentation with rotary files terminated 2 mm short of AF and did not cause any cracks. Significantly less cracks and detachments occurred when instrumentation with rotary files was terminated short of AF, as compared with that terminated at or beyond AF (P hand instruments; instrumentation short of AF reduced the risk of dentinal defects. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  2. File Type Identification of File Fragments using Longest Common Subsequence (LCS)

    Science.gov (United States)

    Rahmat, R. F.; Nicholas, F.; Purnamawati, S.; Sitompul, O. S.

    2017-01-01

    Computer forensic analyst is a person in charge of investigation and evidence tracking. In certain cases, the file needed to be presented as digital evidence was deleted. It is difficult to reconstruct the file, because it often lost its header and cannot be identified while being restored. Therefore, a method is required for identifying the file type of file fragments. In this research, we propose Longest Common Subsequences that consists of three steps, namely training, testing and validation, to identify the file type from file fragments. From all testing results we can conlude that our proposed method works well and achieves 92.91% of accuracy to identify the file type of file fragment for three data types.

  3. Accessing files in an Internet: The Jade file system

    Science.gov (United States)

    Peterson, Larry L.; Rao, Herman C.

    1991-01-01

    Jade is a new distribution file system that provides a uniform way to name and access files in an internet environment. It makes two important contributions. First, Jade is a logical system that integrates a heterogeneous collection of existing file systems, where heterogeneous means that the underlying file systems support different file access protocols. Jade is designed under the restriction that the underlying file system may not be modified. Second, rather than providing a global name space, Jade permits each user to define a private name space. These private name spaces support two novel features: they allow multiple file systems to be mounted under one directory, and they allow one logical name space to mount other logical name spaces. A prototype of the Jade File System was implemented on Sun Workstations running Unix. It consists of interfaces to the Unix file system, the Sun Network File System, the Andrew File System, and FTP. This paper motivates Jade's design, highlights several aspects of its implementation, and illustrates applications that can take advantage of its features.

  4. Accessing files in an internet - The Jade file system

    Science.gov (United States)

    Rao, Herman C.; Peterson, Larry L.

    1993-01-01

    Jade is a new distribution file system that provides a uniform way to name and access files in an internet environment. It makes two important contributions. First, Jade is a logical system that integrates a heterogeneous collection of existing file systems, where heterogeneous means that the underlying file systems support different file access protocols. Jade is designed under the restriction that the underlying file system may not be modified. Second, rather than providing a global name space, Jade permits each user to define a private name space. These private name spaces support two novel features: they allow multiple file systems to be mounted under one directory, and they allow one logical name space to mount other logical name spaces. A prototype of the Jade File System was implemented on Sun Workstations running Unix. It consists of interfaces to the Unix file system, the Sun Network File System, the Andrew File System, and FTP. This paper motivates Jade's design, highlights several aspects of its implementation, and illustrates applications that can take advantage of its features.

  5. Log files can and should be prepared for a functionalistic approach

    DEFF Research Database (Denmark)

    Bergenholtz, Henning; Johnsen, Mia

    2007-01-01

    -ups. However, log file analyses have also been characterised by a juggling of num­bers based on data calculations of limited direct relevance to practical and theoretical lexicography. This article proposes the development of lexicographically relevant log files for the use in log file analyses in order...

  6. Incidence of apical root cracks and apical dentinal detachments after canal preparation with hand and rotary files at different instrumentation lengths

    NARCIS (Netherlands)

    Liu, R.; Kaiwar, A.; Shemesh, H.; Wesselink, P.R.; Hou, B.; Wu, M.K.

    2013-01-01

    Introduction The aim of this study was to compare the incidence of apical root cracks and dentinal detachments after canal preparation with hand and rotary files at different instrumentation lengths. Methods Two hundred forty mandibular incisors were mounted in resin blocks with simulated

  7. Evaluation of apically extruded debris during root canal preparation in primary molar teeth using three different rotary systems and hand files.

    Science.gov (United States)

    Topçuoğlu, Gamze; Topçuoğlu, Hüseyin Sinan; Akpek, Firdevs

    2016-09-01

    To assess the amount of debris extruded apically during root canal preparation using various nickel titanium instrumentation systems and hand files in primary molar teeth. Sixty extracted primary first mandibular molar human teeth were randomly assigned to four groups (n = 15 teeth for each group). The canals were then instrumented with the following instrument systems: Revo-S, Mtwo, ProTaper Next, and hand files. Apically extruded debris during instrumentation was collected into pre-weighed Eppendorf tubes. The Eppendorf tubes were then stored in an incubator at 70°C for 5 days. The weight of the dry extruded debris was established by subtracting the pre-instrumentation and post-instrumentation weight of the Eppendorf tubes for each group. The data were analyzed using one-way analysis of variance (anova) and Tukey's post hoc tests. ProTaper Next files were associated with less apically extruded debris than the Mtwo, Revo-S, and hand files (P Hand files extruded more debris than Mtwo and Revo-S instruments (P 0.05). All instruments were associated with apical extrusion of debris. ProTaper Next files caused less debris extrusion compared to the other systems used. © 2015 BSPD, IAPD and John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Evaluation of the incidence of microcracks caused by Mtwo and ProTaper Next rotary file systems versus the self-adjusting file: A scanning electron microscopic study.

    Science.gov (United States)

    Saha, Suparna Ganguly; Vijaywargiya, Neelam; Saxena, Divya; Saha, Mainak Kanti; Bharadwaj, Anuj; Dubey, Sandeep

    2017-01-01

    To evaluate the incidence of microcrack formation canal preparation with two rotary nickel-titanium systems Mtwo and ProTaper Next along with the self-adjusting file system. One hundred and twenty mandibular premolar teeth were selected. Standardized access cavities were prepared and the canals were manually prepared up to size 20 after coronal preflaring. The teeth were divided into three experimental groups and one control group ( n = 30). Group 1: The canals were prepared using Mtwo rotary files. Group 2: The canals were prepared with ProTaper Next files. Group 3: The canals were prepared with self-adjusting files. Group 4: The canals were unprepared and used as a control. The roots were sectioned horizontally 3, 6, and 9 mm from the apex and examined under a scanning electron microscope to check for the presence of microcracks. The Pearson's Chi-square test was applied. The highest incidence of microcracks were associated with the ProTaper Next group, 80% ( P = 0.00), followed by the Mtwo group, 70% ( P = 0.000), and the least number of microcracks was noted in the self-adjusting file group, 10% ( P = 0.068). No significant difference was found between the ProTaper Next and Mtwo groups ( P = 0.368) while a significant difference was observed between the ProTaper Next and self-adjusting file groups ( P = 0.000) as well as the Mtwo and self-adjusting file groups ( P = 0.000). All nickel-titanium rotary instrument systems were associated with microcracks. However, the self-adjusting file system had significantly fewer microcracks when compared with the Mtwo and ProTaper Next.

  9. Status and evaluation methods of JENDL fusion file and JENDL PKA/KERMA file

    International Nuclear Information System (INIS)

    Chiba, S.; Fukahori, T.; Shibata, K.; Yu Baosheng; Kosako, K.

    1997-01-01

    The status of evaluated nuclear data in the JENDL fusion file and PKA/KERMA file is presented. The JENDL fusion file was prepared in order to improve the quality of the JENDL-3.1 data especially on the double-differential cross sections (DDXs) of secondary neutrons and gamma-ray production cross sections, and to provide DDXs of secondary charged particles (p, d, t, 3 He and α-particle) for the calculation of PKA and KERMA factors. The JENDL fusion file contains evaluated data of 26 elements ranging from Li to Bi. The data in JENDL fusion file reproduce the measured data on neutron and charged-particle DDXs and also on gamma-ray production cross sections. Recoil spectra in PKA/KERMA file were calculated from secondary neutron and charged-particle DDXs contained in the fusion file with two-body reaction kinematics. The data in the JENDL fusion file and PKA/KERMA file were compiled in ENDF-6 format with an MF=6 option to store the DDX data. (orig.)

  10. Interoperability format translation and transformation between IFC architectural design file and simulation file formats

    Science.gov (United States)

    Chao, Tian-Jy; Kim, Younghun

    2015-01-06

    Automatically translating a building architecture file format (Industry Foundation Class) to a simulation file, in one aspect, may extract data and metadata used by a target simulation tool from a building architecture file. Interoperability data objects may be created and the extracted data is stored in the interoperability data objects. A model translation procedure may be prepared to identify a mapping from a Model View Definition to a translation and transformation function. The extracted data may be transformed using the data stored in the interoperability data objects, an input Model View Definition template, and the translation and transformation function to convert the extracted data to correct geometric values needed for a target simulation file format used by the target simulation tool. The simulation file in the target simulation file format may be generated.

  11. PREPAR: a user-friendly preprocessor to create AIRDOS-EPA input data sets

    International Nuclear Information System (INIS)

    Sjoreen, A.L.; Miller, C.W.; Nelson, C.B.

    1984-01-01

    PREPAR is a FORTRAN program designed to simplify the preparation of input for the AIRDOS-EPA computer code. PREPAR was designed to provide a method for data entry that is both logical and flexible. It also provides default values for all variables, so the user needs only to enter those data for which the defaults should be changed. Data are entered either unformatted or via a user-selected format. A separate file of the nuclide-specific data needed by AIRDOS-EPA is read by PREPAR. Two utility programs, EXTRAC and RADLST, were written to create and list this file. PREPAR writes the file needed to run AIRDOS-EPA and writes a listing of that file

  12. Working length changes in curved canals after coronal flaring by using rotary files and hand file: An in vitro study.

    Science.gov (United States)

    Kumar, Rahul; Khambete, Neha; Patil, Suvarna; Hoshing, Upendra; Medha, Ashish; Shetty, Roshan

    2013-09-01

    This in vitro investigation examined the effect of early coronal flaring (CF) and late CF on the working length (WL) in curved root canals. The objective of this study was to determine if canal length is altered as a result of CF in curved canals of molar roots. The conditions compared were combinations of (a) stainless steel hand files using Gates Glidden (G. G.) drills (SS) versus nickel-titanium rotary files (Ni-Ti); and (b) early CF (flaring completed before WL determination) versus late CF (flaring completed after WL determination). Selected were 90 canals of extracted maxillary or mandibular first molars (mesial root of mandibular molars and the mesiobuccal root of the maxillary molars) from three groups. CF was accomplished for the SS group using G. G. drills and for the Ni-Ti group using rotary ProTaper and Hero Shaper files. WL was determined by a digital vernier caliper before CF, immediately after CF, and again after canal preparation. A repeated measures analysis of variance (ANOVA) test and a Tukey's multiple prosthoc test were used for this study. Results indicated that WL decreased for all canals as a result of canal preparation. The mean decrease in WL was significantly greater for the SS group (-0.77 ± 0.42 mm) than for the Ni-Ti groups (-0.33 mm ± 0.44). Less change in WL occurred in all groups when initial WL was determined after CF. WL in curved canals consistently decreases during the course of instrumentation. Clinician should keep this in mind for better treatment outcome.

  13. Evaluation of surface preparation and maintenance of canal curvature following instrumentation with hand 'K' file and three different Ni-Ti rotary systems: A radiographic and SEM study.

    Science.gov (United States)

    Bhatti, Namrata; Sroa, Renu; Sikri, Vimal K

    2010-04-01

    To determine the shaping ability and cleaning efficiency of hand K-flexofiles, ProTaper, LightSpeed and Mtwo instruments during the preparation of curved root canals in extracted human teeth. A total of 120 root canals of mandibular and maxillary molars with curvature more than 20° were divided into four groups of 30 each. In group A, canals were prepared using hand K-flexofiles following the crown down technique. In group B LightSpeed, in group C ProTaper, and in group D Mtwo rotary instruments were used to prepare the root canals. Using pre- and post-instrumentation radiographs, straightening of the canal curvature was determined with Corel Draw 9.0 software tools. The amount of debris and smear layer were quantified at three different areas (coronal, middle, and apical thirds) of root canal using SEM. The collected data were analyzed statistically using Student's paired 't' test. The mean change in curvature for hand K-files was 7.71°, for ProTaper files 6.03°, for Mtwo 5.43°, and for LightSpeed instruments were found to be 4.57°. The percentage change in the curvature for all the four groups was statistically highly significant (PProTaper (65.48%) followed by Mtwo (66.22%), LightSpeed (71.67%) and the maximum with hand K-files (74.16%). However, the difference in mean leftover debris between ProTaper and Mtwo was not significant. ProTaper and Mtwo resulted in good cleaning, and LightSpeed maintained the original canal curvature better than the ProTaper, Mtwo, or Hand K-files.

  14. Effect of reciprocating file motion on microcrack formation in root canals: an SEM study.

    Science.gov (United States)

    Ashwinkumar, V; Krithikadatta, J; Surendran, S; Velmurugan, N

    2014-07-01

    To compare dentinal microcrack formation whilst using Ni-Ti hand K-files, ProTaper hand and rotary files and the WaveOne reciprocating file. One hundred and fifty mandibular first molars were selected. Thirty teeth were left unprepared and served as controls, and the remaining 120 teeth were divided into four groups. Ni-Ti hand K-files, ProTaper hand files, ProTaper rotary files and WaveOne Primary reciprocating files were used to prepare the mesial canals. Roots were then sectioned 3, 6 and 9 mm from the apex, and the cut surface was observed under scanning electron microscope (SEM) and checked for the presence of dentinal microcracks. The control and Ni-Ti hand K-files groups were not associated with microcracks. In roots prepared with ProTaper hand files, ProTaper rotary files and WaveOne Primary reciprocating files, dentinal microcracks were present. There was a significant difference between control/Ni-Ti hand K-files group and ProTaper hand files/ProTaper rotary files/WaveOne Primary reciprocating file group (P ProTaper rotary files producing the most microcracks. No significant difference was observed between teeth prepared with ProTaper hand files and WaveOne Primary reciprocating files. ProTaper rotary files were associated with significantly more microcracks than ProTaper hand files and WaveOne Primary reciprocating files. Ni-Ti hand K-files did not produce microcracks at any levels inside the root canals. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  15. NJOY99, Data Processing System of Evaluated Nuclear Data Files ENDF Format

    International Nuclear Information System (INIS)

    2000-01-01

    and prepares plots of cross sections or perspective views of distributions for output using VIEWR. VIEWR takes the output of PLOTR, or special graphics from HEATR, COVR, DTFR, or ACER, and converts the plots into Postscript format for printing or screen display. MIXR is used to combine cross sections into elements or other mixtures, mainly for plotting. 2 - Methods: NJOY99 consists of a set of modules, each performing a well-defined processing task. Each of these modules is essentially a separate computer program linked together by input and output files and a few common constants. The methods and instructions on how to use them are documented in the LA-12740-M report on NJOY91 and in the 'README' file. No new published document is yet available. NJOY99 is a cleaned up version of NJOY 97.107 that features improved consistency between different systems, more use of block structures, a consistent set of physical constants and support for the CCC-700/MCNP4C Monte Carlo Program. 3 - Restrictions on the complexity of the problem: None noted

  16. JNDC FP decay data file

    International Nuclear Information System (INIS)

    Yamamoto, Tohru; Akiyama, Masatsugu

    1981-02-01

    The decay data file for fission product nuclides (FP DECAY DATA FILE) has been prepared for summation calculation of the decay heat of fission products. The average energies released in β- and γ-transitions have been calculated with computer code PROFP. The calculated results and necessary information have been arranged in tabular form together with the estimated results for 470 nuclides of which decay data are not available experimentally. (author)

  17. Curved canals: Ancestral files revisited

    Directory of Open Access Journals (Sweden)

    Jain Nidhi

    2008-01-01

    Full Text Available The aim of this article is to provide an insight into different techniques of cleaning and shaping of curved root canals with hand instruments. Although a plethora of root canal instruments like ProFile, ProTaper, LightSpeed ® etc dominate the current scenario, the inexpensive conventional root canal hand files such as K-files and flexible files can be used to get optimum results when handled meticulously. Special emphasis has been put on the modifications in biomechanical canal preparation in a variety of curved canal cases. This article compiles a series of clinical cases of root canals with curvatures in the middle and apical third and with S-shaped curvatures that were successfully completed by employing only conventional root canal hand instruments.

  18. Shaping ability of 4 different single-file systems in simulated S-shaped canals.

    Science.gov (United States)

    Saleh, Abdulrahman Mohammed; Vakili Gilani, Pouyan; Tavanafar, Saeid; Schäfer, Edgar

    2015-04-01

    The aim of this study was to compare the shaping ability of 4 different single-file systems in simulated S-shaped canals. Sixty-four S-shaped canals in resin blocks were prepared to an apical size of 25 using Reciproc (VDW, Munich, Germany), WaveOne (Dentsply Maillefer, Ballaigues, Switzerland), OneShape (Micro Méga, Besançon, France), and F360 (Komet Brasseler, Lemgo, Germany) (n = 16 canals/group) systems. Composite images were made from the superimposition of pre- and postinstrumentation images. The amount of resin removed by each system was measured by using a digital template and image analysis software. Canal aberrations and the preparation time were also recorded. The data were statistically analyzed by using analysis of variance, Tukey, and chi-square tests. Canals prepared with the F360 and OneShape systems were better centered compared with the Reciproc and WaveOne systems. Reciproc and WaveOne files removed significantly greater amounts of resin from the inner side of both curvatures (P files was significantly faster compared with WaveOne and F360 files (P file instruments were safe to use and were able to prepare the canals efficiently. However, single-file systems that are less tapered seem to be more favorable when preparing S-shaped canals. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. [Shaping ability of multi-taper nickel-titanium files in simulated resin curved root canal].

    Science.gov (United States)

    Luo, Hong-Xia; Huang, Ding-Ming; Jia, Liu-He; Luo, Shi-Gao; Gao, Xiao-Jie; Tan, Hong; Zhou, Xue-Dong

    2006-08-01

    To compare the shaping ability of ISO standard stainless steel K files and multi-taper ProTaper nickel-titanium files in simulated resin curved root canals. METHODS Thirty simulated resin root canals were randomly divided into three groups and prepared by stainless steel K files, hand ProTaper, rotary ProTaper, respectively. The amount of material removed from inner and outer wall and canal width after canal preparation was measured, while the canal curvature before and after canal preparation and canals aberrations were recorded. The stainless steel K files removed more material than hand ProTaper and rotary ProTaper at the outer side of apex and inner side of curvature (P ProTaper group (P ProTaper had no evident aberration. The shaping ability of ProTaper is better than stainless steel K files.

  20. Log Files Can and Should be Prepared for a Functionalistic Approach

    Directory of Open Access Journals (Sweden)

    Henning Bergenholtz

    2011-10-01

    Full Text Available

    Abstract: User surveys of printed dictionaries may be characterised as non-representative and non-realistic laboratory tests, often with retrospective questions based on memory. Log file analy-ses concerning the use of Internet dictionaries, on the other hand, are based on large numbers of users and look-ups. However, log file analyses have also been characterised by a juggling of num-bers based on data calculations of limited direct relevance to practical and theoretical lexicography. This article proposes the development of lexicographically relevant log files for the use in log file analyses in order to give a true picture of how and why different dictionaries are employed for different purposes.

    Keywords: LEXICOGRAPHY, LOG FILES, DICTIONARY, INTERNET DICTIONARY, SEARCH OPTIONS, DICTIONARY FUNCTION, RECEPTION, TEXT PRODUCTION, TRANS-LATION, COMMUNICATIVE FUNCTION, COGNITIVE FUNCTION, DICTIONARY USE, USER SURVEY, LEMMA, DICTIONARY ITEM, USER NEEDS

    Opsomming: Loglêers kan en behoort voorberei te word vir 'n funksiona-listiese benadering. Gebruikersopnames van gedrukte woordeboeke kan gekarakteriseer word as nieverteenwoordigende en nierealistiese laboratoriumtoetse, dikwels met retrospektiewe vrae gebaseer op geheue. Loglêerontledings betreffende die gebruik van Internetwoordeboeke, aan die ander kant, is gebaseer op groot getalle gebruikers en raadplegings. Loglêerontledings word egter ook gekenmerk deur 'n gegoël met getalle gebaseer op databerekeninge van beperkte direkte tersaaklikheid vir die praktiese en teoretiese leksikografie. Hierdie artikel stel die ontwikkeling van leksikografies tersaaklike loglêers voor vir gebruik in loglêerontledings om 'n ware beeld te gee van hoe en waarom verskillende woordeboeke vir veskillende doeleindes aangewend word.

    Sleutelwoorde: LEKSIKOGRAFIE, LOGLÊERS, WOORDEBOEK, INTERNETWOORDE-BOEK, SOEKKEUSES, WOORDEBOEKFUNKSIE, ONTVANGS, TEKSPRODUKSIE, VERTA-LING, KOMMUNIKATIEWE

  1. Smear layer and debris removal using manual Ni-Ti files compared with rotary Protaper Ni- Ti files - An In-Vitro SEM study.

    Science.gov (United States)

    Reddy, J M V Raghavendra; Latha, Prasanna; Gowda, Basavana; Manvikar, Varadendra; Vijayalaxmi, D Benal; Ponangi, Kalyana Chakravarthi

    2014-02-01

    Predictable successful endodontic therapy depends on correct diagnosis, effective cleaning, shaping and disinfection of the root canals and adequate obturation. Irrigation serves as a flush to remove debris, tissue solvent and lubricant from the canal irregularities; however these irregularities can restrict the complete debridement of root canal by mechanical instrumentation.Various types of hand and rotary instruments are used for the preparation of the root canal system to obtain debris free canals. The purpose of this study was to evaluate the amount of smear layer and debris removal on canal walls following the using of manual Nickel-Titanium (NiTi) files compared with rotary ProTaperNiTi files using a Scanning Electron Microscope in two individual groups. A comparative study consisting of 50 subjects randomized into two groups - 25 subjects in Group A (manual) and 25 subjects in Group B (rotary) was undertaken to investigate and compare the effects of smear layer and debris between manual and rotary NiTi instruments. Chi square test was used to find the significance of smear layer and debris removal in the coronal, middle and apical between Group A and Group B. Both systems of Rotary ProTaperNiTi and manual NiTi files used in the present study, did not create completely clean root canals. Manual NiTi files produced significantly less smear layer and debris compared to Rotary ProTaperNiTi instruments. Rotary instruments were less time consuming when compared to manual instruments. Instrument separation was not found to be significant with both the groups. Both systems of Rotary ProTaperNiTi and manual NiTi files used did not produce completely clean root canals. Manual NiTi files produced significantly less smear layer and debris compared to Rotary protaper instruments. How to cite the article: Reddy JM, Latha P, Gowda B, Manvikar V, Vijayalaxmi DB, Ponangi KC. Smear layer and debris removal using manual Ni-Ti files compared with rotary Protaper Ni-Ti files

  2. Comparative evaluation of debris extruded apically by using, Protaper retreatment file, K3 file and H-file with solvent in endodontic retreatment

    Directory of Open Access Journals (Sweden)

    Chetna Arora

    2012-01-01

    Full Text Available Aim: The aim of this study was to evaluate the apical extrusion of debris comparing 2 engine driven systems and hand instrumentation technique during root canal retreatment. Materials and Methods: Forty five human permanent mandibular premolars were prepared using the step-back technique, obturated with gutta-percha/zinc oxide eugenol sealer and cold lateral condensation technique. The teeth were divided into three groups: Group A: Protaper retreatment file, Group B: K3, file Group C: H-file with tetrachloroethylene. All the canals were irrigated with 20ml distilled water during instrumentation. Debris extruded along with the irrigating solution during retreatment procedure was carefully collected in preweighed Eppendorf tubes. The tubes were stored in an incubator for 5 days, placed in a desiccator and then re-weighed. Weight of dry debris was calculated by subtracting the weight of the tube before instrumentation and from the weight of the tube after instrumentation. Data was analyzed using Two Way ANOVA and Post Hoc test. Results : There was statistically significant difference in the apical extrusion of debris between hand instrumentation and protaper retreatment file and K3 file. The amount of extruded debris caused by protaper retreatment file and K3 file instrumentation technique was not statistically significant. All the three instrumentation techniques produced apically extruded debris and irrigant. Conclusion: The best way to minimize the extrusion of debris is by adapting crown down technique therefore the use of rotary technique (Protaper retreatment file, K3 file is recommended.

  3. EVALUATED NUCLEAR STRUCTURE DATA FILE. A MANUAL FOR PREPARATION OF DATA SETS

    International Nuclear Information System (INIS)

    TULI, J.K.

    2001-01-01

    This manual describes the organization and structure of the Evaluated Nuclear Structure Data File (ENSDF). This computer-based file is maintained by the National Nuclear Data Center (NNDC) at Brookhaven National Laboratory for the international Nuclear Structure and Decay Data Network. For every mass number (presently, A ≤ 293), the Evaluated Nuclear Structure Data File (ENSDF) contains evaluated structure information. For masses A ≥ 44, this information is published in the Nuclear Data Sheets; for A < 44, ENSDF is based on compilations published in the journal Nuclear Physics. The information in ENSDF is updated by mass chain or by nuclide with a varying cycle time dependent on the availability of new information

  4. A Metadata-Rich File System

    Energy Technology Data Exchange (ETDEWEB)

    Ames, S; Gokhale, M B; Maltzahn, C

    2009-01-07

    Despite continual improvements in the performance and reliability of large scale file systems, the management of file system metadata has changed little in the past decade. The mismatch between the size and complexity of large scale data stores and their ability to organize and query their metadata has led to a de facto standard in which raw data is stored in traditional file systems, while related, application-specific metadata is stored in relational databases. This separation of data and metadata requires considerable effort to maintain consistency and can result in complex, slow, and inflexible system operation. To address these problems, we have developed the Quasar File System (QFS), a metadata-rich file system in which files, metadata, and file relationships are all first class objects. In contrast to hierarchical file systems and relational databases, QFS defines a graph data model composed of files and their relationships. QFS includes Quasar, an XPATH-extended query language for searching the file system. Results from our QFS prototype show the effectiveness of this approach. Compared to the defacto standard, the QFS prototype shows superior ingest performance and comparable query performance on user metadata-intensive operations and superior performance on normal file metadata operations.

  5. Evaluation of surface preparation and maintenance of canal curvature following instrumentation with hand ′K′ file and three different Ni-Ti rotary systems: A radiographic and SEM study

    Directory of Open Access Journals (Sweden)

    Namrata Bhatti

    2010-01-01

    Full Text Available Aim: To determine the shaping ability and cleaning efficiency of hand K-flexofiles, ProTaper, LightSpeed and Mtwo instruments during the preparation of curved root canals in extracted human teeth. Materials and Methods: A total of 120 root canals of mandibular and maxillary molars with curvature more than 20° were divided into four groups of 30 each. In group A, canals were prepared using hand K-flexofiles following the crown down technique. In group B LightSpeed, in group C ProTaper, and in group D Mtwo rotary instruments were used to prepare the root canals. Using pre- and post-instrumentation radiographs, straightening of the canal curvature was determined with Corel Draw 9.0 software tools. The amount of debris and smear layer were quantified at three different areas (coronal, middle, and apical thirds of root canal using SEM. The collected data were analyzed statistically using Student′s paired ′t′ test. Results: The mean change in curvature for hand K-files was 7.71°, for ProTaper files 6.03°, for Mtwo 5.43°, and for LightSpeed instruments were found to be 4.57°. The percentage change in the curvature for all the four groups was statistically highly significant (P< 0.01. LightSpeed instruments maintained the original canal curvature significantly (P< 0.01 better than the other instruments. For leftover debris, the minimum percentage was found to be associated with ProTaper (65.48% followed by Mtwo (66.22%, LightSpeed (71.67% and the maximum with hand K-files (74.16%. However, the difference in mean leftover debris between ProTaper and Mtwo was not significant. Conclusion: ProTaper and Mtwo resulted in good cleaning, and LightSpeed maintained the original canal curvature better than the ProTaper, Mtwo, or Hand K-files.

  6. Securing the AliEn File Catalogue - Enforcing authorization with accountable file operations

    International Nuclear Information System (INIS)

    Schreiner, Steffen; Banerjee, Subho Sankar; Betev, Latchezar; Carminati, Federico; Vladimirovna Datskova, Olga; Furano, Fabrizio; Grigoras, Alina; Grigoras, Costin; Mendez Lorenzo, Patricia; Peters, Andreas Joachim; Saiz, Pablo; Bagnasco, Stefano; Zhu Jianlin

    2011-01-01

    The AliEn Grid Services, as operated by the ALICE Collaboration in its global physics analysis grid framework, is based on a central File Catalogue together with a distributed set of storage systems and the possibility to register links to external data resources. This paper describes several identified vulnerabilities in the AliEn File Catalogue access protocol regarding fraud and unauthorized file alteration and presents a more secure and revised design: a new mechanism, called LFN Booking Table, is introduced in order to keep track of access authorization in the transient state of files entering or leaving the File Catalogue. Due to a simplification of the original Access Envelope mechanism for xrootd-protocol-based storage systems, fundamental computational improvements of the mechanism were achieved as well as an up to 50% reduction of the credential's size. By extending the access protocol with signed status messages from the underlying storage system, the File Catalogue receives trusted information about a file's size and checksum and the protocol is no longer dependent on client trust. Altogether, the revised design complies with atomic and consistent transactions and allows for accountable, authentic, and traceable file operations. This paper describes these changes as part and beyond the development of AliEn version 2.19.

  7. Substance P and Calcitonin gene-related peptide expression in human periodontal ligament after root canal preparation with Reciproc Blue, WaveOne Gold, XP EndoShaper and hand files.

    Science.gov (United States)

    Caviedes-Bucheli, J; Rios-Osorio, N; Rey-Rojas, M; Laguna-Rivero, F; Azuero-Holguin, M M; Diaz, L E; Curtidor, H; Castaneda-Ramirez, J J; Munoz, H R

    2018-05-17

    To quantify the Substance P (SP) and Calcitonin gene-related peptide (CGRP) expression in healthy human periodontal ligament from premolars after root canal preparation with Reciproc Blue, WaveOne Gold, XP EndoShaper and hand files. Fifty human periodontal ligament samples were obtained from healthy mandibular premolars where extraction was indicated for orthodontic reasons. Prior to extraction, 40 of these premolars were equally divided into four groups, and root canals were prepared using four different systems: Reciproc Blue, WaveOne Gold, XP EndoShaper, and a hand instrumentation technique. The remaining 10 healthy premolars were extracted without treatment and served as a negative control group. All periodontal ligament samples were processed, and SP and CGRP were measured by radioimmunoassay. The Kruskal-Wallis test was used to establish significant differences between groups and LSD post hoc comparisons were also performed. Greater SP and CGRP values were found in the hand instrumentation group, followed by the XP EndoShaper, WaveOne Gold and the Reciproc groups. The lower SP and CGRP values were for the healthy periodontal ligament group. The Kruskal-Wallis test revealed significant differences between groups (p 0.05). All the root canal preparation techniques tested increased SP and CGRP expression in human periodontal ligament, with hand files and XP EndoShaper instruments being associated with greater neuropeptide release compared to Reciproc Blue and WaveOne Gold files. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  8. Stool consistency and stool frequency are excellent clinical markers for adequate colon preparation after polyethylene glycol 3350 cleansing protocol: a prospective clinical study in children.

    Science.gov (United States)

    Safder, Shaista; Demintieva, Yulia; Rewalt, Mary; Elitsur, Yoram

    2008-12-01

    Colon preparation for a colonoscopy in children is a difficult task because of the unpalatable taste and large volume of cleansing solution that needs to be consumed to ensure a clean colon. Consequently, an unprepared colon frequently occurs in routine practices, which causes early termination and a repeated procedure. (1) To assess the effectiveness of polyethylene glycol solution (PEG 3350) in preparing the colon of children scheduled for a colonoscopy and (2) to investigate clinical markers associated with an adequate colon preparation before a colonoscopy. A total of 167 children scheduled for a colonoscopy. In a prospective study, children scheduled for a colonoscopy were given PEG 3350 solution (1.5 g/kg per day, up to 100 g/d) over a 4-day preparation period. Each day, a simple questionnaire that documents the amount of liquid consumed, adverse effects, and the number and consistency of stool was completed by the parents. After a colonoscopy procedure, the colon preparation was assigned a number grade. The data were later assessed and were compared to determine the association between the grade of cleansing and the frequency and/or consistency of stool during preparation. Colon preparation was completed in 149 children, 133 of whom were adequately prepared. Inadequate preparation was found in 16 children; the procedure was terminated prematurely in 2 of these patients because of unacceptable conditions. No significant adverse effects were noted. A number of >or=5 stools/d, and liquid stool consistency in the last 2 days of preparation were associated with adequate colon preparation. PEG 3350 solution is safe, efficacious, and tolerable for children. Stool frequency and consistency in the last 2 days of preparation were excellent markers (positive predictive value 91%-95%), which predict an adequately clean colon before a colonoscopy in children.

  9. Evaluated nuclear-data file for niobium

    International Nuclear Information System (INIS)

    Smith, A.B.; Smith, D.L.; Howerton, R.J.

    1985-03-01

    A comprehensive evaluated nuclear-data file for elemental niobium is provided in the ENDF/B format. This file, extending over the energy range 10 -11 -20 MeV, is suitable for comprehensive neutronic calculations, particulary those dealing with fusion-energy systems. It also provides dosimetry information. Attention is given to the internal consistancy of the file, energy balance, and the quantitative specification of uncertainties. Comparisons are made with experimental data and previous evaluated files. The results of integral tests are described and remaining outstanding problem areas are cited. 107 refs

  10. Seed Protein Content and Consistency of Tofu Prepared with Different Magnesium Chloride Concentrations in Six Japanese Soybean Varieties

    OpenAIRE

    Toda, Kyoko; Ono, Tomotada; Kitamura, Keisuke; Hajika, Makita; Takahashi, Koji; Nakamura, Yoshiyuki

    2003-01-01

    The relationship between the protein content of soybean seeds and the consistency of tofu was examined for six Japanese soybean varieties, Enrei, Fukuyutaka, Sachiyutaka, Ayakogane, Hatayutaka and Tachinagaha. The seed protein content was estimated by determining the nitrogen content using the Dumas method. Tofu was prepared from a raw homogenate of water-soaked soybeans by heating and by the addition of MgCl_2 as a coagulant. The tofu consistency was evaluated by measuring the breaking stres...

  11. Electronic licensing filing system development and implementation experience

    International Nuclear Information System (INIS)

    Walderhaug, J.

    1993-01-01

    The Electronic Licensing Filing System (ELFS) is a microcomputer-based integrated document search and retrieval system for the Nuclear Regulatory Affairs Division of Southern California Edison (SCE). ELFS allows the user access to the current licensing basis of a subject by providing an easily searchable electronic information data base consisting of regulatory correspondence, design-bases documentation, licensing documents [updated final safety and analysis report (UFSAR) and technical specifications], and regulatory guidance or directives [10CFR, generic letters, bulletins, notices, circulars, regulatory guides, policy statements, and selected US Nuclear Regulatory Commission (NRC) regulations]. It is used in the preparation of correspondence and submittals to the NRC, 50.59 safety evaluations, design-bases reconstitution, and commitment tracking and management

  12. Smear layer removal evaluation of different protocol of Bio Race file and XP- endo Finisher file in corporation with EDTA 17% and NaOCl.

    Science.gov (United States)

    Zand, Vahid; Mokhtari, Hadi; Reyhani, Mohammad-Frough; Nahavandizadeh, Neda; Azimi, Shahram

    2017-11-01

    The aim of the present study was to compare the amount of the smear layer remaining in prepared root canals with different protocols of Bio RaCe files and XP-endo Finisher file (XPF) in association with 17% EDTA and sodium hypochlorite solution. A total of 68 extracted single-rooted teeth were randomly divided into 4 experimental groups (n=14) and two control groups (n=6). The root canals were prepared with Bio RaCe files (FKG Dentaire, Switzerland) using the crown-down technique based on manufacturer's instructions and irrigated according to the following irrigation techniques: Group 1: XPF with 2 mL of 2.5% NaOCl for 1 minute. Group 2:, XPF with 1 mL of 17% EDTA for one minute. Group 3: XPF was used for 1 minute in association with normal saline solution. Group 4: XP-endo Finisher file for 30 seconds in association with 2.5% NaOCl and 17% EDTA for 30 seconds. The negative control group: NaOCl (2.5%) was used during root canal preparation, followed by irrigation with 17% EDTA at the end of root canal preparation. The positive control group: Normal saline solution was used for irrigation during root canal preparation. In all the groups, during preparation of the root canals with Bio RaCe file, 20 mL of 2.5% NaOCl was used for root canal irrigation and at the end of the procedural steps 20 mL of normal saline solution was used as a final irrigant. The samples were analyzed under SEM at ×1000‒2000 magnification and evaluated using Torabinejad scoring system. Data were analyzed with non-parametric Kruskal-Wallis test and post hoc Mann-Whitney U test, using SPSS. Statistical significant was defined at P <0.05. The results of the study showed the least amount of the smear layer at coronal, middle and apical thirds of the root canals in groups 2, which was not significantly different from the negative control group ( P <0.5). Under the limitations of the present study, use of a combination of NaOCl and EDTA in association with XPF exhibited the best efficacy for the

  13. GEODOC: the GRID document file, record structure and data element description

    Energy Technology Data Exchange (ETDEWEB)

    Trippe, T.; White, V.; Henderson, F.; Phillips, S.

    1975-11-06

    The purpose of this report is to describe the information structure of the GEODOC file. GEODOC is a computer based file which contains the descriptive cataloging and indexing information for all documents processed by the National Geothermal Information Resource Group. This file (along with other GRID files) is managed by DBMS, the Berkeley Data Base Management System. Input for the system is prepared using the IRATE Text Editing System with its extended (12 bit) character set, or punched cards.

  14. Titanium-II: an evaluated nuclear data file

    International Nuclear Information System (INIS)

    Philis, C.; Howerton, R.; Smith, A.B.

    1977-06-01

    A comprehensive evaluated nuclear data file for elemental titanium is outlined including definition of the data base, the evaluation procedures and judgments, and the final evaluated results. The file describes all significant neutron-induced reactions with elemental titanium and the associated photon-production processes to incident neutron energies of 20.0 MeV. In addition, isotopic-reaction files, consistent with the elemental file, are separately defined for those processes which are important to applied considerations of material-damage and neutron-dosimetry. The file is formulated in the ENDF format. This report formally documents the evaluation and, together with the numerical file, is submitted for consideration as a part of the ENDF/B-V evaluated file system. 20 figures, 9 tables

  15. Nuclear Structure References (NSR) file

    International Nuclear Information System (INIS)

    Ewbank, W.B.

    1978-08-01

    The use of the Nuclear Structure References file by the Nuclear Data Project at ORNL is described. Much of the report concerns format information of interest only to those preparing input to the system or otherwise needing detailed knowledge of its internal structure. 17 figures

  16. 17 CFR 232.13 - Date of filing; adjustment of filing date.

    Science.gov (United States)

    2010-04-01

    ..., shall not affect the date of filing. (2) If the conditions of paragraph (a)(1) of this section are... and consistent with the public interest and the protection of investors. (c) Payment of fees. Fees...

  17. Apical extrusion of debris during root canal preparation using a novel nickel-titanium file system: WaveOne gold.

    Science.gov (United States)

    Dincer, Asiye Nur; Guneser, Mehmet Burak; Arslan, Dilara

    2017-01-01

    This study was intended to evaluate the amount of apically extruded debris following root canal preparation with three different instrumentation systems. Sixty mandibular incisor teeth were selected and randomly divided into three groups ( n = 20/group) according to the instrumentation system used: the ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland), the Twisted File Adaptive (TFA; SybronEndo, Orange, CA, USA), and the WaveOne Gold (WOG; Dentsply Maillefer, Ballaigues, Switzerland). All apically extruded debris was collected and dried in preweighed glass vials. The mean weight of the apically extruded debris was obtained using a microbalance. The time for root canal preparation was also recorded. The data were analyzed using a one-way analysis of variance. The mean weights of apically extruded debris were 0.00035 ± 0.00014 g (PTN); 0.00023 ± 0.0001 g (TFA); and 0.00019 ± 0.0001 g (WOG) ( P system extruded more debris than the TFA and WOG systems. The TFA and WOG systems were faster than the PTN system.

  18. The consistency service of the ATLAS Distributed Data Management system

    CERN Document Server

    Serfon, C; The ATLAS collaboration

    2011-01-01

    With the continuously increasing volume of data produced by ATLAS and stored on the WLCG sites, the probability of data corruption or data losses, due to software and hardware failures is increasing. In order to ensure the consistency of all data produced by ATLAS a Consistency Service has been developed as part of the DQ2 Distributed Data Management system. This service is fed by the different ATLAS tools, i.e. the analysis tools, production tools, DQ2 site services or by site administrators that report corrupted or lost files. It automatically corrects the errors reported and informs the users in case of irrecoverable file loss.

  19. The Consistency Service of the ATLAS Distributed Data Management system

    CERN Document Server

    Serfon, C; The ATLAS collaboration

    2010-01-01

    With the continuously increasing volume of data produced by ATLAS and stored on the WLCG sites, the probability of data corruption or data losses, due to software and hardware failure is increasing. In order to ensure the consistency of all data produced by ATLAS a Consistency Service has been developed as part of the DQ2 Distributed Data Management system. This service is fed by the different ATLAS tools, i.e. the analysis tools, production tools, DQ2 site services or by site administrators that report corrupted or lost files. It automatically correct the errors reported and informs the users in case of irrecoverable file loss.

  20. LHCb Data Management: consistency, integrity and coherence of data

    CERN Document Server

    Bargiotti, Marianne

    2007-01-01

    The Large Hadron Collider (LHC) at CERN will start operating in 2007. The LHCb experiment is preparing for the real data handling and analysis via a series of data challenges and production exercises. The aim of these activities is to demonstrate the readiness of the computing infrastructure based on WLCG (Worldwide LHC Computing Grid) technologies, to validate the computing model and to provide useful samples of data for detector and physics studies. DIRAC (Distributed Infrastructure with Remote Agent Control) is the gateway to WLCG. The Dirac Data Management System (DMS) relies on both WLCG Data Management services (LCG File Catalogues, Storage Resource Managers and File Transfer Service) and LHCb specific components (Bookkeeping Metadata File Catalogue). Although the Dirac DMS has been extensively used over the past years and has proved to achieve a high grade of maturity and reliability, the complexity of both the DMS and its interactions with numerous WLCG components as well as the instability of facilit...

  1. Supplemental Security Income Public-Use Microdata File, 2001 Data

    Data.gov (United States)

    Social Security Administration — The SSI Public-Use Microdata File contains an extract of data fields from SSA's Supplemental Security Record file and consists of a 5 percent random, representative...

  2. Skyshine analysis using various nuclear data files

    International Nuclear Information System (INIS)

    Zharkov, V.P.; Dikareva, O.F.; Kartashev, I.A.; Kiselev, A.N.; Nomura, Y.; Tsubosaka, A.

    2000-01-01

    The calculations of the spacial distributions of dose rate for neutron and secondary photons, thermal neutron fluxes and space-energy distributions of neutron and photons near the air-ground interface were performed by MCNP and DORT codes. Different nuclear data files were used (ENDF/B-IV, ENDF/B-VI, FENDL-2, JENDL-3.2). Either the standard pointwise libraries (MCNP) or special libraries prepared by NJOY code from ENDF/B and others' files were used. Prepared multigroup coupled neutron and photon cross sections libraries for DORT code had CASK-40 group energy structures. The libraries contain pointwise or multigroup cross sections data for all elements included in the atmosphere and ground composition. The validation of the calculated results was performed with using the experimental data obtained for the series of measurements at RA reactor. (author)

  3. Data Management Applications for the Service Preparation Subsystem

    Science.gov (United States)

    Luong, Ivy P.; Chang, George W.; Bui, Tung; Allen, Christopher; Malhotra, Shantanu; Chen, Fannie C.; Bui, Bach X.; Gutheinz, Sandy C.; Kim, Rachel Y.; Zendejas, Silvino C.; hide

    2009-01-01

    These software applications provide intuitive User Interfaces (UIs) with a consistent look and feel for interaction with, and control of, the Service Preparation Subsystem (SPS). The elements of the UIs described here are the File Manager, Mission Manager, and Log Monitor applications. All UIs provide access to add/delete/update data entities in a complex database schema without requiring technical expertise on the part of the end users. These applications allow for safe, validated, catalogued input of data. Also, the software has been designed in multiple, coherent layers to promote ease of code maintenance and reuse in addition to reducing testing and accelerating maturity.

  4. A fortran code CVTRAN to provide cross-section file for TWODANT by using macroscopic file written by SRAC

    International Nuclear Information System (INIS)

    Yamane, Tsuyoshi; Tsuchihashi, Keichiro

    1999-03-01

    A code CVTRAN provides the macroscopic cross-sections in the format of XSLIB file which is one of Standard interface files for a two-dimensional Sn transport code TWODANT by reading a macroscopic cross section file in the PDS format which is prepared by SRAC execution. While a two-dimensional Sn transport code TWOTRAN published by LANL is installed as a module in the SRAC code system, several functions such as alpha search, concentration search, zone thickness search and various edits are suppressed. Since the TWODANT code was released from LANL, its short running time, stable convergence and plenty of edits have attracted many users. The code CVTRAN makes the TWODANT available to the SRAC user by providing the macroscopic cross-sections on a card-image file XSLIB. The CVTRAN also provides material dependent fission spectra into a card-image format file CVLIB, together with group velocities, group boundary energies and material names. The user can feed them into the TWODANT input, if necessary, by cut-and-paste command. (author)

  5. INDC/NEANDC nuclear standards file 1980 version

    International Nuclear Information System (INIS)

    1981-09-01

    This working document of the Nuclear Standards Subcommittee of the International Nuclear Data Committee (INDC) summarizes the status of nuclear standards as of the 11th INDC meeting (6/'80) with selective updating to approximately 5/'81. This version of the file is presented in two sections as per the following. The first section (A) consists of numerical tabulations of the respective quantities generally including quantitative definition of the uncertainties. Most of these numerical values are taken from the ENDF/B-V file which is available on a world-wide basis through the 4-Center network. Some guidelines as to appropriate usage are also given. The objective is the provision of a concise and readily used reference guide to essential standard-nuclear quantities useful for a diversity of basic and applied endeavors. The second section (B) briefly summarizes the contemporary status of each of the standards tabulated in Section A and additional items, including recent relevant work and areas of continuing uncertainty. These brief reviews were prepared under the auspices of the Committee by outstanding specialists in the respective fields. In many instances they are new statements but, where review indicates that the previous statement (see INDC-30/L+sp) remains appropriate, the previous summaries were retained; often with additional remarks by the editor

  6. The Global File System

    Science.gov (United States)

    Soltis, Steven R.; Ruwart, Thomas M.; OKeefe, Matthew T.

    1996-01-01

    The global file system (GFS) is a prototype design for a distributed file system in which cluster nodes physically share storage devices connected via a network-like fiber channel. Networks and network-attached storage devices have advanced to a level of performance and extensibility so that the previous disadvantages of shared disk architectures are no longer valid. This shared storage architecture attempts to exploit the sophistication of storage device technologies whereas a server architecture diminishes a device's role to that of a simple component. GFS distributes the file system responsibilities across processing nodes, storage across the devices, and file system resources across the entire storage pool. GFS caches data on the storage devices instead of the main memories of the machines. Consistency is established by using a locking mechanism maintained by the storage devices to facilitate atomic read-modify-write operations. The locking mechanism is being prototyped in the Silicon Graphics IRIX operating system and is accessed using standard Unix commands and modules.

  7. The version control service for the ATLAS data acquisition configuration files

    International Nuclear Information System (INIS)

    Soloviev, Igor

    2012-01-01

    The ATLAS experiment at the LHC in Geneva uses a complex and highly distributed Trigger and Data Acquisition system, involving a very large number of computing nodes and custom modules. The configuration of the system is specified by schema and data in more than 1000 XML files, with various experts responsible for updating the files associated with their components. Maintaining an error free and consistent set of XML files proved a major challenge. Therefore a special service was implemented; to validate any modifications; to check the authorization of anyone trying to modify a file; to record who had made changes, plus when and why; and to provide tools to compare different versions of files and to go back to earlier versions if required. This paper provides details of the implementation and exploitation experience, that may be interesting for other applications using many human-readable files maintained by different people, where consistency of the files and traceability of modifications are key requirements.

  8. Comparative evaluation of fracture and defect in reciproc and rotary files in severe curved root canals

    Directory of Open Access Journals (Sweden)

    Mahdis Bagherian

    2015-03-01

    Full Text Available Introduction: Root canal instrumentation is an important phase in root canal therapy. Since success in endodontic treatment depends on file defect and fracture, the aim of this study was to compare the evaluation of defect and fracture in rotary and reciproc files in severe curved root canals. Materials & Methods: In this experimental study, 60 mesial canals of human closed apex molars with more than 30° canal curvature were randomly divided into two groups. In first group M-two rotary files number# 15, 20, and 25 and in second group R25 reciproc file were used for filing, respectively. A ×8 magnifier was applied to evaluate the defect or fracture presence in each side and if it were observed, a new file would be replaced. Therefore, the number of prepared canals with each file and fractured or defective files and the place of fracture in root canal were recorded. Kaplan Meier curve and log rank test were done by using SPSS v.22. Results: In rotary group, seven and two files were fractured and defected, respectively and four files were fractured and no defect was observed in reciproc group. Although the mean of the number of prepared canals until fracture or defect in rotary and reciproc groups was 3.3 and 7.06, respectively, there were no significant differences between two systems. All file’s fractures occurred in apical regions . Conclusion: The results showed that there was no significant difference in defects or fractures of rotary and reciproc systems. Reciproc instruments can be more effective than rotary ones because the root canal preparation in rotary instruments is longer than in reciproc system.

  9. Cleanliness of endodontic files after use and before sterilization

    Directory of Open Access Journals (Sweden)

    Maria de Lourdes Portella

    2008-01-01

    Full Text Available Objectives: To evaluate the efficacy of two endodontic file cleaning methods: manual and with the use of ultrasonic vat Method: Sixty-six endodontic files were used for root canal preparations and afterwards divided into three groups: 1 manual cleaning; 2ultrasonic cleaning; 3 files used in patients, but were not cleaned (positive control.Results: Statistical analysis showed that in the case of manually cleaned files, the percentage of cleaning was 0.4% while in those that were dirty it was 99.6%. In the case of ultrasonic cleaning, the cleaning percentage was 49.21% while the percentage of dirt was 50.79%. Conclusion: The most satisfactory result was obtained with the use of ultrasound, and it is suggested that after ultrasound, brushing, the use of liquid soap and water, and drying should be performed for adequate cleaning of endodontic files.

  10. Evaluation of Root Canal Preparation Using Rotary System and Hand Instruments Assessed by Micro-Computed Tomography

    Science.gov (United States)

    Stavileci, Miranda; Hoxha, Veton; Görduysus, Ömer; Tatar, Ilkan; Laperre, Kjell; Hostens, Jeroen; Küçükkaya, Selen; Muhaxheri, Edmond

    2015-01-01

    Background Complete mechanical preparation of the root canal system is rarely achieved. Therefore, the purpose of this study was to evaluate and compare the root canal shaping efficacy of ProTaper rotary files and standard stainless steel K-files using micro-computed tomography. Material/Methods Sixty extracted upper second premolars were selected and divided into 2 groups of 30 teeth each. Before preparation, all samples were scanned by micro-computed tomography. Thirty teeth were prepared with the ProTaper system and the other 30 with stainless steel files. After preparation, the untouched surface and root canal straightening were evaluated with micro-computed tomography. The percentage of untouched root canal surface was calculated in the coronal, middle, and apical parts of the canal. We also calculated straightening of the canal after root canal preparation. Results from the 2 groups were statistically compared using the Minitab statistical package. Results ProTaper rotary files left less untouched root canal surface compared with manual preparation in coronal, middle, and apical sector (protary techniques completely prepared the root canal, and both techniques caused slight straightening of the root canal. PMID:26092929

  11. Skyshine analysis using various nuclear data files

    Energy Technology Data Exchange (ETDEWEB)

    Zharkov, V.P.; Dikareva, O.F.; Kartashev, I.A.; Kiselev, A.N. [Research and Development Inst. of Power Engineering, Moscow (Russian Federation); Nomura, Y.; Tsubosaka, A. [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan)

    2000-03-01

    The calculations of the spacial distributions of dose rate for neutron and secondary photons, thermal neutron fluxes and space-energy distributions of neutron and photons near the air-ground interface were performed by MCNP and DORT codes. Different nuclear data files were used (ENDF/B-IV, ENDF/B-VI, FENDL-2, JENDL-3.2). Either the standard pointwise libraries (MCNP) or special libraries prepared by NJOY code from ENDF/B and others' files were used. Prepared multigroup coupled neutron and photon cross sections libraries for DORT code had CASK-40 group energy structures. The libraries contain pointwise or multigroup cross sections data for all elements included in the atmosphere and ground composition. The validation of the calculated results was performed with using the experimental data obtained for the series of measurements at RA reactor. (author)

  12. ProTaper rotary instrument fracture during root canal preparation: a comparison between rotary and hybrid techniques.

    Science.gov (United States)

    Farid, Huma; Khan, Farhan Raza; Rahman, Munawar

    2013-03-01

    This study aimed to compare the frequency of ProTaper rotary instrument fracture with rotary (conventional) and hybrid (rotary and hand files) canal preparation techniques. Secondary objectives were to determine whether there was an association of ProTaper file fracture with the canal curvature and to compare the mean time required for canal preparation in the two techniques. An in vitro experiment was conducted on 216 buccal canals of extracted maxillary and mandibular first molars. After creating an access cavity and a glide path for each canal, a periapical radiograph was taken and the canal curvature was measured with Schneider's technique. The canals were then randomly divided into Group A (rotary technique) and Group B (hybrid technique). The length of ProTaper files were measured before and after each canal preparation. Time taken for each canal preparation was recorded. A total of seven ProTaper files fractured in Group A (P=0.014) in canals with a curvature >25 degrees (PProTaper rotary files, although time consuming, was safer in canals having a curvature greater than 25 degrees.

  13. Benchmark comparisons of evaluated nuclear data files

    International Nuclear Information System (INIS)

    Resler, D.A.; Howerton, R.J.; White, R.M.

    1994-05-01

    With the availability and maturity of several evaluated nuclear data files, it is timely to compare the results of integral tests with calculations using these different files. We discuss here our progress in making integral benchmark tests of the following nuclear data files: ENDL-94, ENDF/B-V and -VI, JENDL-3, JEF-2, and BROND-2. The methods used to process these evaluated libraries in a consistent way into applications files for use in Monte Carlo calculations is presented. Using these libraries, we are calculating and comparing to experiment k eff for 68 fast critical assemblies of 233,235 U and 239 Pu with reflectors of various material and thickness

  14. Evaluation of Root Canal Preparation Using Rotary System and Hand Instruments Assessed by Micro-Computed Tomography.

    Science.gov (United States)

    Stavileci, Miranda; Hoxha, Veton; Görduysus, Ömer; Tatar, Ilkan; Laperre, Kjell; Hostens, Jeroen; Küçükkaya, Selen; Muhaxheri, Edmond

    2015-06-20

    Complete mechanical preparation of the root canal system is rarely achieved. Therefore, the purpose of this study was to evaluate and compare the root canal shaping efficacy of ProTaper rotary files and standard stainless steel K-files using micro-computed tomography. Sixty extracted upper second premolars were selected and divided into 2 groups of 30 teeth each. Before preparation, all samples were scanned by micro-computed tomography. Thirty teeth were prepared with the ProTaper system and the other 30 with stainless steel files. After preparation, the untouched surface and root canal straightening were evaluated with micro-computed tomography. The percentage of untouched root canal surface was calculated in the coronal, middle, and apical parts of the canal. We also calculated straightening of the canal after root canal preparation. Results from the 2 groups were statistically compared using the Minitab statistical package. ProTaper rotary files left less untouched root canal surface compared with manual preparation in coronal, middle, and apical sector (p<0.001). Similarly, there was a statistically significant difference in root canal straightening after preparation between the techniques (p<0.001). Neither manual nor rotary techniques completely prepared the root canal, and both techniques caused slight straightening of the root canal.

  15. Nuclear decay data files of the Dosimetry Research Group

    International Nuclear Information System (INIS)

    Eckerman, K.F.; Westfall, R.J.; Ryman, J.C.; Cristy, M.

    1993-12-01

    This report documents the nuclear decay data files used by the Dosimetry Research Group at Oak Ridge National Laboratory and the utility DEXRAX which provides access to the files. The files are accessed, by nuclide, to extract information on the intensities and energies of the radiations associated with spontaneous nuclear transformation of the radionuclides. In addition, beta spectral data are available for all beta-emitting nuclides. Two collections of nuclear decay data are discussed. The larger collection contains data for 838 radionuclides, which includes the 825 radionuclides assembled during the preparation of Publications 30 and 38 of the International Commission on Radiological Protection (ICRP) and 13 additional nuclides evaluated in preparing a monograph for the Medical Internal Radiation Dose (MIRD) Committee of the Society of Nuclear Medicine. The second collection is composed of data from the MIRD monograph and contains information for 242 radionuclides. Abridged tabulations of these data have been published by the ICRP in Publication 38 and by the Society of Nuclear Medicine in a monograph entitled ''MIRD: Radionuclide Data and Decay Schemes.'' The beta spectral data reported here have not been published by either organization. Electronic copies of the files and the utility, along with this report, are available from the Radiation Shielding Information Center at Oak Ridge National Laboratory

  16. Investigation of stability, consistency, and oil oxidation of emulsion filled gel prepared by inulin and rice bran oil using ultrasonic radiation.

    Science.gov (United States)

    Nourbehesht, Newsha; Shekarchizadeh, Hajar; Soltanizadeh, Nafiseh

    2018-04-01

    Inulin, rice bran oil and rosemary essential oil were used to produce high quality emulsion filled gel (EFG) using ultrasonic radiation. Response surface methodology was used to investigate the effects of oil content, inulin content and power of ultrasound on the stability and consistency of prepared EFG. The process conditions were optimized by conducting experiments at five different levels. Second order polynomial response surface equations were developed indicating the effect of variables on EFG stability and consistency. The oil content of 18%; inulin content of 44.6%; and power of ultrasound of 256 W were found to be the optimum conditions to achieve the best EFG stability and consistency. Microstructure and rheological properties of prepared EFG were investigated. Oil oxidation as a result of using ultrasonic radiation was also investigated. The increase of oxidation products and the decrease of total phenolic compounds as well as radical scavenging activity of antioxidant compounds showed the damaging effect of ultrasound on the oil quality of EFG. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. The Effect of Volume of Transaction On The Intention Towards Tax E-filing

    Directory of Open Access Journals (Sweden)

    Aziz Saliza Abdul

    2017-01-01

    Full Text Available Volume of transaction is specifically referring to number of clients or return forms dealing by tax agents/preparers. This variable does play role even though there is less empirical evidence on this matter. This paper is basically to explore the effect of volume of transaction that could possibly influence the acceptance of tax e-filing system as it did in other areas of transaction i.e. court cases. Undoubtedly, it is proved to be significantly influenced the behavioural intention towards tax e-filing acceptability in Malaysia. The tax agents/preparers are randomly selected in this study from the list provided in the Inland Revenue Board of Malaysia (IRBM website. The responds are analysed via Partial Least Square (PLS method which produce the significant results among the low and high volume of transaction of tax e-filing which support the fact that volume does matter in the decision of acceptability of tax e-filing system in Malaysia.

  18. Cleaning capacity of hybrid instrumentation technique using reamer with alternating cutting edges system files: Histological analysis

    Directory of Open Access Journals (Sweden)

    Emilio Carlos Sponchiado Junior

    2014-01-01

    Full Text Available Aim: The aim of the following study is to evaluate the cleaning capacity of a hybrid instrumentation technique using Reamer with Alternating Cutting Edges (RaCe system files in the apical third of mesial roots of mandibular molars. Materials and Methods: Twenty teeth were selected and separated into two groups (n = 20 according to instrumentation technique as follows: BioRaCe - chemomechanical preparation with K-type files #10 and #15; and files BioRaCe BR0, BR1, BR2, BR3, and BR4; HybTec - hybrid instrumentation technique with K-type files #10 and #15 in the working length, #20 at 2 mm, #25 at 3 mm, cervical preparation with Largo burs #1 and #2; apical preparation with K-type files #15, #20, and #25 and RaCe files #25.04 and #30.04. The root canals were irrigated with 1 ml of 2.5% sodium hypochlorite at each change of instrument. The specimens were histologically processed and photographed under light optical microscope. The images were inserted onto an integration grid to count the amount of debris present in the root canal. Results: BioRaCe presented the highest percentage of debris in the apical third, however, with no statistically significant difference for HybTec (P > 0.05. Conclusions: The hybrid technique presented similar cleaning capacity as the technique recommended by the manufacturer.

  19. A novel approach to determine the effect of irrigation on temperature and failure of Ni-Ti endodontic rotary files

    Science.gov (United States)

    Mousavi, Sayed Ali; Kargar-Dehnavi, Vida; Mousavi, Sayed Amir

    2012-01-01

    Background: Nickel-titanium (Ni-Ti) rotary instrument files are important devices in Endodontics in root canal preparation. Ni-Ti file breakage is a critical and problematic issue and irrigation techniques were applied to decrease risk of file failure root. The aim of the present study was to compare the temperature gradient change of different irrigation solutions with Ni-Ti rotary instrument system during root canal preparation and also to define their effects on the file failure. Materials and Methods: A novel computerized instrumentation was utilized and thirty standard (ProFile #25/.04) files were divided into three groups and subjected to a filing in the root canal test. Changes in temperature on teeth under constant instrumental conditions with custom-designed computerized experimental apparatus were measured by using a temperature sensor bonded to the apical hole. A rotary instrument for canal preparation in three series of solution was used and the changes in temperature after each solution were compared. Finally, the file failure results were mentored according to each step of test. Comparisons were performed between group status clinically by using ANOVA (t) test, once the sample showed up normal and differences of Pinstruments, which were immersed in 5% NaOCl, when compared with the water group (Pinstruments immersed in water, when compared with the no solution group (Pinstruments. Conclusion: By immersing the file in 5% NaOCl, the temperature gradient decreased and instrument failure was reduced. PMID:23087732

  20. Incidence of dentinal defects after preparation of severely curved root canals using the Reciproc single-file system with and without prior creation of a glide path.

    Science.gov (United States)

    Saber, S E D M; Schäfer, E

    2016-11-01

    To investigate the incidence of dentinal defects after preparation of severely curved root canals using the Reciproc single-file system with and without prior creation of a glide path. Mesial roots from extracted mandibular first molars were collected and scanned with CBCT to assess the morphology of the root canal systems. Three groups of 20 anatomically comparable specimens were generated. The control group was left unprepared, whilst the experimental groups were prepared with Reciproc R25 with and without a glide path (groups RG and R, respectively). Roots were then sectioned perpendicular to the long axis at 2, 4, 6, 8 and 10 mm from the apex, and coloured photographs of the sections at 40× were obtained. Two blinded examiners registered the presence of dentinal defects twice at 2-week interval. Data were statistically analysed using the Fisher exact and Cochran's Q tests. No defects were observed in the control group. The overall incidence of dentinal defects was 26% in group R and 24% in group RG, with no significant differences between them (P > 0.05). Dentinal defects occurred significantly more often in the middle and coronal thirds compared to the apical third of the canals (P files. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  1. Clinical Evaluation of Quality of Obturation and Instrumentation Time using Two Modified Rotary File Systems with Manual Instrumentation in Primary Teeth.

    Science.gov (United States)

    Govindaraju, Lavanya; Jeevanandan, Ganesh; Subramanian, Emg

    2017-09-01

    Pulp therapy in primary teeth has been performed using various instrumentation techniques. However, the conventional instrumentation technique used for root canal preparation in primary teeth is hand instrumentation. Various Nickel-Titanium (Ni-Ti) instruments are available to perform efficient root canal preparation in primary teeth. These Ni-Ti instruments has been designed to aid in better root canal preparation in permanent teeth but are rarely used in primary teeth. It is necessary to assess the feasibility of using these adult rotary files with a modified sequence in primary teeth. To compare the quality of obturation and instrumentation time during root canal preparation using hand files and modified rotary file systems in primary molars. Forty-five primary mandibular molars were randomly assigned to three experimental groups (n=15). Group I was instrumented using k-hand files, Group II with S2 ProTaper universal file and Group III with 0.25 tip 4% taper K3 rotary file. Standardized digital radiographs were taken before and after root canal instrumentation. Root canal preparation time was also recorded. Statistical analysis of the obtained data was done using SPSS Software version 17.0. An intergroup comparison of the instrumentation time and the quality of obturation was done using ANOVA and Chi-square test with the level of significance set at 0.05. No significant differences were noted with regard to the quality of obturation (p=0.791). However, a statistically significant difference was noted in the instrumentation time between the three groups (pProTaper rotary system had significantly lesser instrumentation time when compared to that of K3 rotary system and hand file system. The hand files, S2 ProTaper Universal and K3 0.25 tip 4% taper files systems performed similarly with respect to the quality of obturation. There was a significant difference in instrumentation time with manual instrumentation compared to the modified rotary file systems in primary

  2. Endodontic treatment of mandibular molar with root dilaceration using Reciproc single-file system.

    Science.gov (United States)

    Meireles, Daniely Amorin; Bastos, Mariana Mena Barreto; Marques, André Augusto Franco; Garcia, Lucas da Fonseca Roberti; Sponchiado, Emílio Carlos

    2013-08-01

    Biomechanical preparation of root canals with accentuated curvature is challenging. New rotatory systems, such as Reciproc, require a shorter period of time to prepare curved canals, and became a viable alternative for endodontic treatment of teeth with root dilaceration. Thus, this study aimed to report a clinical case of endodontic therapy of root with accentuated dilaceration using Reciproc single-file system. Mandibular right second molar was diagnosed as asymptomatic irreversible pulpitis. Pulp chamber access was performed, and glide path was created with #10 K-file (Dentsply Maillefer) and PathFile #13, #16 and #19 (Dentsply Maillefer) up to the temporary working length. The working length measured corresponded to 20 mm in the mesio-buccal and mesio-lingual canals, and 22 mm in the distal canal. The R25 file (VDW GmbH) was used in all the canals for instrumentation and final preparation, followed by filling with Reciproc gutta-percha cones (VDW GmbH) and AH Plus sealer (Dentsply Maillefer), using thermal compaction technique. The case has been receiving follow-up for 6 mon and no painful symptomatology or periapical lesions have been found. Despite the difficulties, the treatment could be performed in a shorter period of time than the conventional methods.

  3. Endodontic treatment of mandibular molar with root dilaceration using Reciproc single-file system

    Directory of Open Access Journals (Sweden)

    Daniely Amorin Meireles

    2013-08-01

    Full Text Available Biomechanical preparation of root canals with accentuated curvature is challenging. New rotatory systems, such as Reciproc, require a shorter period of time to prepare curved canals, and became a viable alternative for endodontic treatment of teeth with root dilaceration. Thus, this study aimed to report a clinical case of endodontic therapy of root with accentuated dilaceration using Reciproc single-file system. Mandibular right second molar was diagnosed as asymptomatic irreversible pulpitis. Pulp chamber access was performed, and glide path was created with #10 K-file (Dentsply Maillefer and PathFile #13, #16 and #19 (Dentsply Maillefer up to the temporary working length. The working length measured corresponded to 20 mm in the mesio-buccal and mesio-lingual canals, and 22 mm in the distal canal. The R25 file (VDW GmbH was used in all the canals for instrumentation and final preparation, followed by filling with Reciproc gutta-percha cones (VDW GmbH and AH Plus sealer (Dentsply Maillefer, using thermal compaction technique. The case has been receiving follow-up for 6 mon and no painful symptomatology or periapical lesions have been found. Despite the difficulties, the treatment could be performed in a shorter period of time than the conventional methods.

  4. The crystallographic information file (CIF): A new standard archive file for crystallography

    International Nuclear Information System (INIS)

    Hall, S.R.; Allen, F.H.; Brown, I.D.

    1991-01-01

    The specification of a new standard Crystallographic Information File (CIF) is described. Its development is based on the Self-Defining Text Archieve and Retrieval (STAR) procedure. The CIF is a general, flexible and easily extensible free-format archive file; it is human and machine readable and can be edited by a simple editor. The CIF is designed for the electronic transmission of crystallographic data between individual laboratories, journals and databases: It has been adopted by the International Union of Crystallography as the recommended medium for this purpose. The file consists of data names and data items, together with a loop facility for repeated items. The data names, constructed hierarchically so as to form data categories, are self-descriptive within a 32-character limit. The sorted list of data names, together with their precise definitions, constitutes the CIF dictionary (core version 1991). The CIF core dictionary is presented in full and covers the fundamental and most commonly used data items relevant to crystal structure analysis. The dictionary is also available as an electronic file suitable for CIF computer applications. Future extensions to the dictionary will include data items used in more specialized areas of crystallography. (orig.)

  5. Comparison of Cleaning Efficacy and Instrumentation Time in Primary Molars: Mtwo Rotary Instruments vs. Hand K-Files.

    Science.gov (United States)

    Ramezanali, Fatemeh; Afkhami, Farzaneh; Soleimani, Ali; Kharrazifard, Mohammad Javad; Rafiee, Farshid

    2015-01-01

    Pulpectomy is the preferred treatment for restorable primary teeth with symptomatic irreversible pulpitis or periradicular lesion. Considering the rather new application of rotary files for pulpectomy of primary teeth, the aim of this study was to compare the cleaning efficacy and instrumentation time of hand K-files and Mtwo rotary system for preparation of human primary molars. This experimental study was conducted on 100 extracted primary maxillary and mandibular intact molars with no resorption. Access cavities were prepared and India ink was injected into the root canal on a vibrator using an insulin syringe. Canals were then divided into 5 groups (n=20): in group I, canals were instrumented using K-files up to #25 for mesial and buccal canals and #30 for palatal and distal canals. In group II, canals were prepared using Mtwo rotary files (15/0.05, 20/0.06 and 25/0.06 for mesial and buccal canals and 15/0.05, 20/0.06, 25/0.06 and finally 30/0.05 for distal and palatal canals). In group III, root canals were only irrigated with saline. Groups IV and V were the positive and negative control groups, respectively. The time required for cleaning and preparation of the canals for each of the specimens in groups I, II and III was recorded. The mean score of cleanliness of Mtwo was not significantly different from K-file group (P>0.05). However the mean instrumentation time in Mtwo group was significantly shorter (Protary files were far more time efficient.

  6. Computer-aided preparation of specifications for radial fans at VEB Lufttechnische Anlagen Berlin

    Energy Technology Data Exchange (ETDEWEB)

    Kubis, R.; Kull, W.

    1987-01-01

    The specification details the scope of delivery for radial fans on a standard page and also serves the preparation for production. In the place of previous manual preparation, a computer-aided technique for the office computer is presented that provides the technical parameters from data files out of few input data to identify the fan type. The data files and evaluative programs are based on the software tool REDABAS and the SCP operating system. Using this technique it has been possible to cut considerably the preparation time for the incoming orders.

  7. Status of the evaluated nuclear structure data file

    International Nuclear Information System (INIS)

    Martin, M.J.

    1991-01-01

    The structure, organization, and contents of the Evaluated Nuclear Structure Data File (ENSDF) are discussed in this paper. This file contains a summary of the state of experimental nuclear structure data for all nuclides as determined from consideration of measurements reported worldwide in the literature. Special emphasis is given to the data evaluation procedures, the consistency checks, and the quality control utilized at the input stage and to the retrieval capabilities of the system at the output stage. Recent enhancements of the on-line interaction with the file contents is addressed as well as procedural changes that will improve the currency of the file

  8. 14 CFR 248.2 - Filing of audit reports.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Filing of audit reports. 248.2 Section 248...) ECONOMIC REGULATIONS SUBMISSION OF AUDIT REPORTS § 248.2 Filing of audit reports. (a) Whenever any air... Information, in duplicate, a special report consisting of a true and complete copy of the audit report...

  9. Consistent interpretation of neutron-induced charged-particle emission in silicon

    International Nuclear Information System (INIS)

    Hermsdorf, D.

    1982-06-01

    Users requesting gas production cross sections for Silicon will be confronted with serious discrepancies taking evaluated data as well as experimental ones. To clarify the accuracies achieved at present in experiments and evaluations in this paper an intercomparison of different evaluated nuclear data files has been carried out resulting in recommendations for improvements of these files. The analysis of the experimental data base also shows contradictory measurements or in most cases a lack of data. So an interpretation of reliable measured data in terms of nuclear reaction theories has been done using statistical and direct reaction mechanism models. This study results in a consistent and comprehensive evaluated data set for neutron-induced charged-particle production in Silicon which will be incorporated in file 2015 of the SOKRATOR library. (author)

  10. Effects of Self-Adjusting File, Mtwo, and ProTaper on the root canal wall

    NARCIS (Netherlands)

    Hin, E.S.; Wu, M.K.; Wesselink, P.R.; Shemesh, H.

    2013-01-01

    Introduction The purpose of this ex vivo study was to observe the incidence of cracks in root dentin after root canal preparation with hand files, self-adjusting file (SAF), ProTaper, and Mtwo. Methods One hundred extracted mandibular premolars with single canals were randomly selected. Two

  11. The Jade File System. Ph.D. Thesis

    Science.gov (United States)

    Rao, Herman Chung-Hwa

    1991-01-01

    design. The prototype consists of interfaces to the Unix File System, the Sun Network File System, and the File Transfer Protocol.

  12. SIDS-toADF File Mapping Manual

    Science.gov (United States)

    McCarthy, Douglas; Smith, Matthew; Poirier, Diane; Smith, Charles A. (Technical Monitor)

    2002-01-01

    The "CFD General Notation System" (CGNS) consists of a collection of conventions, and conforming software, for the storage and retrieval of Computational Fluid Dynamics (CFD) data. It facilitates the exchange of data between sites and applications, and helps stabilize the archiving of aerodynamic data. This effort was initiated in order to streamline the procedures in exchanging data and software between NASA and its customers, but the goal is to develop CGNS into a National Standard for the exchange of aerodynamic data. The CGNS development team is comprised of members from Boeing Commercial Airplane Group, NASA-Ames, NASA-Langley, NASA-Lewis, McDonnell-Douglas Corporation (now Boeing-St. Louis), Air Force-Wright Lab., and ICEM-CFD Engineering. The elements of CGNS address all activities associated with the storage of data on external media and its movement to and from application programs. These elements include: 1) The Advanced Data Format (ADF) Database manager, consisting of both a file format specification and its I/O software, which handles the actual reading and writing of data from and to external storage media; 2) The Standard Interface Data Structures (SIDS), which specify the intellectual content of CFD data and the conventions governing naming and terminology; 3) The SIDS-to-ADF File Mapping conventions, which specify the exact location where the CFD data defined by the SIDS is to be stored within the ADF file(s); and 4) The CGNS Mid-level Library, which provides CFD-knowledgeable routines suitable for direct installation into application codes. The SIDS-toADF File Mapping Manual specifies the exact manner in which, under CGNS conventions, CFD data structures (the SIDS) are to be stored in (i.e., mapped onto) the file structure provided by the database manager (ADF). The result is a conforming CGNS database. Adherence to the mapping conventions guarantees uniform meaning and location of CFD data within ADF files, and thereby allows the construction of

  13. Root Canal Cleaning Efficacy of Rotary and Hand Files Instrumentation in Primary Molars

    Science.gov (United States)

    Nazari Moghaddam, Kiumars; Mehran, Majid; Farajian Zadeh, Hamideh

    2009-01-01

    INTRODUCTION: Pulpectomy of primary teeth is commonly carried out with hand files and broaches; a tricky and time consuming procedure. The purpose of this in vitro study was to compare the cleaning efficacy and time taken for instrumentation of deciduous molars using hand K-files and Flex Master rotary system. MATERIALS AND METHODS: In this study, 68 canals of 23 extracted primary molars with at least two third intact roots and 7-12 mm length were selected. After preparing an access cavity, K-file size #15 was introduced into the root canal and India ink was injected with an insulin syringe. Sixty samples were randomly divided in to experimental groups in group I (n=30), root canals were prepared with hand K-files; in group II (n=30), rotary Flex Master files were used for instrumentation, and in group III 8 remained samples were considered as negative controls. After clearing and root sectioning, the removal of India ink from cervical, middle, and apical thirds was scored. Data was analyzed using student's T-test and Mann-Whitney U test. RESULTS: There was no significant difference between experimental groups cleaning efficacy at the cervical, middle and apical root canal thirds. Only the coronal third scored higher in the hand instrumented group (PInstrumentation with Flex Master rotary files was significantly less time consuming (Protary technique. PMID:23940486

  14. A study on FlexMaster : a Ni-Ti rotary engine driven system for root canal preparation.

    Science.gov (United States)

    Alam, M S; Bashar, A K; Begumr, J A; Kinoshita, J I

    2006-07-01

    In the present study, the effectiveness of recently introduced rotary Nickel Titanium FlexMaster engine driven system was evaluated for cleaning and shaping of root canals in extracted human teeth and compared with that done by the Nickel Titanium Flexofile hand instruments. A total of 40 root canals from 36 extracted mandibular and maxillary teeth with curvature ranging between 20 and 30 degree were divided into two groups, consisting 20 canals in each. FlexMaster instrumentation was done in 20 canals, using crown-down technique and manual filing with Flexofile was done in other 20 canals, using conventional and step-back techniques. 5.25% sodium hypochlorite (NaOCl) solution and 17% ethelene di-amine tetra-acetic acid (EDTA) were used alternatively for irrigation after canal preparation by each instrument size. Time needed for canal preparation of individual canal was recorded. A procedural error such as instrument breakage was also noted. After preparation, all the roots were cut longitudinally by using diamond burs in turbine handpiece and examined under scanning electron microscope. Apical region was quantified for debris and smear layer based on a 5-score numerical evaluation scale. The data established for scoring the debris and smear layer and preparation time of individual canal were analyzed statistically using the Mann-Whitney U test. Completely cleaned root canals were not found with any of the two instruments and none of the instruments maintained the original canal uniformity and regular dentine surface. Because significantly less debris was found in the apical region using the manual filing technique (p< 0.05). Thus the flexmaster system was found to produce less cleaner root canal walls than manual technique. Only one FlexMaster finishing file sized 30 was separated in the apical region during preparation of 30 degree curved canal. The time taken by FlexMaster was significantly better (p< 0.01) than that of hand instruments.

  15. ENSDF: The evaluated nuclear structure data file

    International Nuclear Information System (INIS)

    Martin, M.J.

    1986-01-01

    The structure, organization, and contents of the Evaluated Nuclear Structure Data File, ENSDF, will be discussed. This file summarizes the state of experimental nuclear structure data for all nuclei as determined from consideration of measurements reported world wide. Special emphasis will be given to the data evaluation procedures and consistency checks utilized at the input stage and to the retrieval capabilities of the system at the output stage

  16. Optimization of preparation method for ketoprofen-loaded microspheres consisting polymeric blends using simplex lattice mixture design

    Energy Technology Data Exchange (ETDEWEB)

    Das, Sanjoy Kumar, E-mail: sanjoydasju@gmail.com; Khanam, Jasmina; Nanda, Arunabha

    2016-12-01

    In the present investigation, simplex lattice mixture design was applied for formulation development and optimization of a controlled release dosage form of ketoprofen microspheres consisting polymers like ethylcellulose and Eudragit{sup ®}RL 100; when those were formed by oil-in-oil emulsion solvent evaporation method. The investigation was carried out to observe the effects of polymer amount, stirring speed and emulsifier concentration (% w/w) on percentage yield, average particle size, drug entrapment efficiency and in vitro drug release in 8 h from the microspheres. Analysis of variance (ANOVA) was used to estimate the significance of the models. Based on the desirability function approach numerical optimization was carried out. Optimized formulation (KTF-O) showed close match between actual and predicted responses with desirability factor 0.811. No adverse reaction between drug and polymers were observed on the basis of Fourier transform infrared (FTIR) spectroscopy and Differential scanning calorimetric (DSC) analysis. Scanning electron microscopy (SEM) was carried out to show discreteness of microspheres (149.2 ± 1.25 μm) and their surface conditions during pre and post dissolution operations. The drug release pattern from KTF-O was best explained by Korsmeyer-Peppas and Higuchi models. The batch of optimized microspheres were found with maximum entrapment (~ 90%), minimum loss (~ 10%) and prolonged drug release for 8 h (91.25%) which may be considered as favourable criteria of controlled release dosage form. - Graphical abstract: Optimization of preparation method for ketoprofen-loaded microspheres consisting polymeric blends using simplex lattice mixture design. - Highlights: • Simplex lattice design was used to optimize ketoprofen-loaded microspheres. • Polymeric blend (Ethylcellulose and Eudragit® RL 100) was used. • Microspheres were prepared by oil-in-oil emulsion solvent evaporation method. • Optimized formulation depicted favourable

  17. Design and Implementation of a Metadata-rich File System

    Energy Technology Data Exchange (ETDEWEB)

    Ames, S; Gokhale, M B; Maltzahn, C

    2010-01-19

    Despite continual improvements in the performance and reliability of large scale file systems, the management of user-defined file system metadata has changed little in the past decade. The mismatch between the size and complexity of large scale data stores and their ability to organize and query their metadata has led to a de facto standard in which raw data is stored in traditional file systems, while related, application-specific metadata is stored in relational databases. This separation of data and semantic metadata requires considerable effort to maintain consistency and can result in complex, slow, and inflexible system operation. To address these problems, we have developed the Quasar File System (QFS), a metadata-rich file system in which files, user-defined attributes, and file relationships are all first class objects. In contrast to hierarchical file systems and relational databases, QFS defines a graph data model composed of files and their relationships. QFS incorporates Quasar, an XPATH-extended query language for searching the file system. Results from our QFS prototype show the effectiveness of this approach. Compared to the de facto standard, the QFS prototype shows superior ingest performance and comparable query performance on user metadata-intensive operations and superior performance on normal file metadata operations.

  18. Preparation of Cotton-Wool-Like Poly(lactic acid-Based Composites Consisting of Core-Shell-Type Fibers

    Directory of Open Access Journals (Sweden)

    Jian Wang

    2015-11-01

    Full Text Available In previous works, we reported the fabrication of cotton-wool-like composites consisting of siloxane-doped vaterite and poly(l-lactic acid (SiVPCs. Various irregularly shaped bone voids can be filled with the composite, which effectively supplies calcium and silicate ions, enhancing the bone formation by stimulating the cells. The composites, however, were brittle and showed an initial burst release of ions. In the present work, to improve the mechanical flexibility and ion release, the composite fiber was coated with a soft, thin layer consisting of poly(d,l-lactic-co-glycolic acid (PLGA. A coaxial electrospinning technique was used to prepare a cotton-wool-like material comprising “core-shell”-type fibers with a diameter of ~12 µm. The fibers, which consisted of SiVPC coated with a ~2-µm-thick PLGA layer, were mechanically flexible; even under a uniaxial compressive load of 1.5 kPa, the cotton-wool-like material did not exhibit fracture of the fibers and, after removing the load, showed a ~60% recovery. In Tris buffer solution, the initial burst release of calcium and silicate ions from the “core-shell”-type fibers was effectively controlled, and the ions were slowly released after one day. Thus, the mechanical flexibility and ion-release behavior of the composites were drastically improved by the thin PLGA coating.

  19. Decay data file based on the ENSDF file

    Energy Technology Data Exchange (ETDEWEB)

    Katakura, J. [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-03-01

    A decay data file with the JENDL (Japanese Evaluated Nuclear Data Library) format based on the ENSDF (Evaluated Nuclear Structure Data File) file was produced as a tentative one of special purpose files of JENDL. The problem using the ENSDF file as primary source data of the JENDL decay data file is presented. (author)

  20. Effect of Autoclave Cycles on Surface Characteristics of S-File Evaluated by Scanning Electron Microscopy

    OpenAIRE

    Razavian, Hamid; Iranmanesh, Pedram; Mojtahedi, Hamid; Nazeri, Rahman

    2015-01-01

    Introduction: Presence of surface defects in endodontic instruments can lead to unwanted complications such as instrument fracture and incomplete preparation of the canal. The current study was conducted to evaluate the effect of autoclave cycles on surface characteristics of S-File by scanning electron microscopy (SEM). Methods and Materials: In this experimental study, 17 brand new S-Files (#30) were used. The surface characteristics of the files were examined in four steps (without autocla...

  1. 75 FR 50013 - Self-Regulatory Organizations; NYSE Amex, Inc.; Notice of Filing and Immediate Effectiveness of...

    Science.gov (United States)

    2010-08-16

    ... been prepared by the self-regulatory organization. NYSE Amex filed the proposed rule change as a ``non.... Self-Regulatory Organization's Statement of the Terms of Substance of the Proposed Rule Change The... its filing with the Commission, the self-regulatory organization included statements concerning the...

  2. Incidence of dentinal defects after root canal preparation: reciprocating versus rotary instrumentation.

    Science.gov (United States)

    Bürklein, Sebastian; Tsotsis, Polymnia; Schäfer, Edgar

    2013-04-01

    The purpose of this study was to evaluate the incidence of dentinal defects after root canal preparation with reciprocating instruments (Reciproc and WaveOne) and rotary instruments. One hundred human central mandibular incisors were randomly assigned to 5 groups (n = 20 teeth per group). The root canals were instrumented by using the reciprocating single-file systems Reciproc and WaveOne and the full-sequence rotary Mtwo and ProTaper instruments. One group was left unprepared as control. Roots were sectioned horizontally at 3, 6, and 9 mm from the apex and evaluated under a microscope by using 25-fold magnification. The presence of dentinal defects (complete/incomplete cracks and craze lines) was noted and analyzed by using the chi-square test. No defects were observed in the controls. All canal preparation created dentinal defects. Overall, instrumentation with Reciproc was associated with more complete cracks than the full-sequence files (P = .021). Although both reciprocating files produced more incomplete cracks apically (3 mm) compared with the rotary files (P = .001), no statistically significant differences were obtained concerning the summarized values of all cross sections (P > .05). Under the conditions of this study, root canal preparation with both rotary and reciprocating instruments resulted in dentinal defects. At the apical level of the canals, reciprocating files produced significantly more incomplete dentinal cracks than full-sequence rotary systems (P < .05). Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. Relationship between the Apical Preparation Diameter and the Apical Seal: An In Vitro Study

    Directory of Open Access Journals (Sweden)

    Kaoutar Laslami

    2018-01-01

    Full Text Available Objectives. The aim of the study is to define the relationship between the apical preparation diameter and the apical sealing ability to highlight the importance of the preservation of the diameter and the original position of the apical foramen. Materials and Methods. 50 extracted maxillary incisors were randomly allocated into three groups of 15 teeth each (n = 15 according to the apical preparation size: Group 1: finishing file F1 corresponding to size 20 reached the working length (ProTaper Universal system Dentsply®; Group 2: prepared up to size 30 corresponding to finishing file F30; Group 3: prepared up to size 50 corresponding to finishing file F5. Five teeth were assigned to positive and negative control groups. After the filling of the root canals, the teeth were isolated and immersed in a dye solution, then cut longitudinally, photographed, and the dye penetration were calculated using a computer software. Results. Comparison of the three different apical preparation sizes showed no statistically significant differences regarding the apical microleakage. Conclusion. The most important value of the dye penetration was observed in the group with the largest apical diameter.

  4. Prefetching in file systems for MIMD multiprocessors

    Science.gov (United States)

    Kotz, David F.; Ellis, Carla Schlatter

    1990-01-01

    The question of whether prefetching blocks on the file into the block cache can effectively reduce overall execution time of a parallel computation, even under favorable assumptions, is considered. Experiments have been conducted with an interleaved file system testbed on the Butterfly Plus multiprocessor. Results of these experiments suggest that (1) the hit ratio, the accepted measure in traditional caching studies, may not be an adequate measure of performance when the workload consists of parallel computations and parallel file access patterns, (2) caching with prefetching can significantly improve the hit ratio and the average time to perform an I/O (input/output) operation, and (3) an improvement in overall execution time has been observed in most cases. In spite of these gains, prefetching sometimes results in increased execution times (a negative result, given the optimistic nature of the study). The authors explore why it is not trivial to translate savings on individual I/O requests into consistently better overall performance and identify the key problems that need to be addressed in order to improve the potential of prefetching techniques in the environment.

  5. Old Age, Survivors, and Disability Insurance (OASDI) Public-Use Microdata File, 2001 Data

    Data.gov (United States)

    Social Security Administration — The OASDI Public-Use Microdata File contains an extract of data fields from SSA's Master Beneficiary Record file and consists of a 1 percent random, representative...

  6. Reactor fuel performance data file, 1985 edition

    International Nuclear Information System (INIS)

    Harayama, Yasuo; Fujita, Misao; Watanabe, Kohji.

    1986-07-01

    In safety evaluation and integrity studies of reactor fuel, data on fuel performance are the most basic materials. The Fuel Reliability Laboratory No.1 has obtained the fuel performance data by joining in some international programs to study the safety and integrity of fuel. Those data have only used for the studies in the above two fields. However, if the data are rearranged and compiled in a easily usable form, they can be utilized in other field of studies. Then, a 'data file' on fuel performance is beeing compiled by adding data from open literatures to those obtained in international programs. The present report is prepared on the basis of the data file compiled by March in 1986. (author)

  7. Stochastic Petri net analysis of a replicated file system

    Science.gov (United States)

    Bechta Dugan, Joanne; Ciardo, Gianfranco

    1989-01-01

    A stochastic Petri-net model of a replicated file system is presented for a distributed environment where replicated files reside on different hosts and a voting algorithm is used to maintain consistency. Witnesses, which simply record the status of the file but contain no data, can be used in addition to or in place of files to reduce overhead. A model sufficiently detailed to include file status (current or out-of-date), as well as failure and repair of hosts where copies or witnesses reside, is presented. The number of copies and witnesses is a parameter of the model. Two different majority protocols are examined, one where a majority of all copies and witnesses is necessary to form a quorum, and the other where only a majority of the copies and witnesses on operational hosts is needed. The latter, known as adaptive voting, is shown to increase file availability in most cases.

  8. Configuration Management File Manager Developed for Numerical Propulsion System Simulation

    Science.gov (United States)

    Follen, Gregory J.

    1997-01-01

    One of the objectives of the High Performance Computing and Communication Project's (HPCCP) Numerical Propulsion System Simulation (NPSS) is to provide a common and consistent way to manage applications, data, and engine simulations. The NPSS Configuration Management (CM) File Manager integrated with the Common Desktop Environment (CDE) window management system provides a common look and feel for the configuration management of data, applications, and engine simulations for U.S. engine companies. In addition, CM File Manager provides tools to manage a simulation. Features include managing input files, output files, textual notes, and any other material normally associated with simulation. The CM File Manager includes a generic configuration management Application Program Interface (API) that can be adapted for the configuration management repositories of any U.S. engine company.

  9. 76 FR 19976 - Marine Mammals; File No. 15537

    Science.gov (United States)

    2011-04-11

    ... Mammals; File No. 15537 AGENCY: National Marine Fisheries Service (NMFS), National Oceanic and Atmospheric...) prepared in response to a public display permit application received from the Institute for Marine Mammal... of the Marine Mammal Protection Act of 1972, as amended (16 U.S.C. 1361 et seq.) and the regulations...

  10. 77 FR 64970 - Historic Harrisville, Inc.; Notice of Application Accepted for Filing With the Commission, Intent...

    Science.gov (United States)

    2012-10-24

    ... Commission strongly encourages electronic filing, documents may also be paper-filed. To paper-file, mail an... would consist of: (1) The existing 94-foot-long, 29-foot-high quarried-stone Cheshire Mills Dam with a...

  11. 78 FR 8512 - West Street Hydro, Inc.; Notice of Preliminary Permit Application Accepted for Filing and...

    Science.gov (United States)

    2013-02-06

    .... The proposed project would consist of: (1) The existing 160-foot- long, 16-foot-high, stone-masonry... filing, documents may also be paper-filed. To paper-file, mail an original and seven copies to: Kimberly...

  12. ATLAS, an integrated structural analysis and design system. Volume 4: Random access file catalog

    Science.gov (United States)

    Gray, F. P., Jr. (Editor)

    1979-01-01

    A complete catalog is presented for the random access files used by the ATLAS integrated structural analysis and design system. ATLAS consists of several technical computation modules which output data matrices to corresponding random access file. A description of the matrices written on these files is contained herein.

  13. 76 FR 67181 - Windsor Machinery Co., Inc.; Notice of Preliminary Permit Application Accepted for Filing and...

    Science.gov (United States)

    2011-10-31

    ... and consist of: (1) An existing 130-foot-long, 18-foot-high cut stone with a concrete cap dam creating... strongly encourages electronic filing, documents may also be paper-filed. To paper-file, mail an original...

  14. Conversion software for ANSYS APDL 2 FLUENT MHD magnetic file

    International Nuclear Information System (INIS)

    Ghita, G.; Ionescu, S.; Prisecaru, I.

    2016-01-01

    The present paper describes the improvements made to the conversion software for ANSYS APDL 2 FLUENT MHD Magnetic File which is able to extract the data from ANSYS APDL file and write down a file containing the magnetic field data in FLUENT magneto hydro dynamics (MHD) format. The MHD module has some features for the uniform and non uniform magnetic field but it is limited for sinusoidal or pulsed, square wave, having a fixed duty cycle of 50%. The present software, ANSYS APDL 2 FLUENT MHD Magnetic File, suffered major modifications in comparison with the last one. The most important improvement consists in a new graphical interface, which has 3D graphical interface for the input file but also for the output file. Another improvement has been made for processing time, the new version is two times faster comparing with the old one. (authors)

  15. Comparison of Dentinal Crack Formation With Reciproc, Mtwo and ProTaper Root Canal Preparation Systems

    Directory of Open Access Journals (Sweden)

    Nazari Moghaddam

    2016-06-01

    Full Text Available Background Instrumentation with rotary instruments could potentially cause dentinal cracks possibly leading to tooth fracture. Reciproc files require a single file to finalize the root canal preparation and the effect of this procedure has not been compared with other systems. Objectives The aim of this study was to compare the incidence of dentinal micro-cracks following root canal preparations with ProTaper, Mtwo and Reciproc files. Materials and Methods In an experimental in vitro trial, 80 maxillary and mandibular first molars were selected and their crowns and distal roots were cut. The roots were then examined to remove any previous cracks and defects. An impression polyether material was used to simulate teeth periodontal ligament (PDL. The teeth were divided to four experimental groups (n = 20 and prepared using Reciproc, Mtwo and ProTaper or remained unprepared as a control group. The specimens were then sectioned horizontally on 3, 5 and 9 mm from the apex and number of micro-cracks was determined by stereomicroscope. The incidence of dentinal cracks on different systems or sections were statistically analyzed by means of the chi-square test. Results Dentinal defects on 3-mm, 5-mm and 9-mm sections from the apex were noted in 10 (5.6%; 7 (3.9% and 9 (5.0% samples of all, respectively. Following canal preparation using Reciproc, ProTaper and Mtwo systems, the defects were observed in 7 (3.9%, 12 (6.7% and 7 (3.9% the sections, respectively. No significant differences were observed regarding the defect incidence on the studied instrumentation files or sections. Conclusions Regarding the study limitations, dentinal cracks were observed in all files and distances from the apex. Although there was more crack incidence in ProTaper files, no significant differences were noted regarding the studied systems and sections from the apex.

  16. A Centralized Control and Dynamic Dispatch Architecture for File Integrity Analysis

    Directory of Open Access Journals (Sweden)

    Ronald DeMara

    2006-02-01

    Full Text Available The ability to monitor computer file systems for unauthorized changes is a powerful administrative tool. Ideally this task could be performed remotely under the direction of the administrator to allow on-demand checking, and use of tailorable reporting and exception policies targeted to adjustable groups of network elements. This paper introduces M-FICA, a Mobile File Integrity and Consistency Analyzer as a prototype to achieve this capability using mobile agents. The M-FICA file tampering detection approach uses MD5 message digests to identify file changes. Two agent types, Initiator and Examiner, are used to perform file integrity tasks. An Initiator travels to client systems, computes a file digest, then stores those digests in a database file located on write-once media. An Examiner agent computes a new digest to compare with the original digests in the database file. Changes in digest values indicate that the file contents have been modified. The design and evaluation results for a prototype developed in the Concordia agent framework are described.

  17. Comparative study of root-canal shaping with stainless steel and rotary NiTi files performed by preclinical dental students.

    Science.gov (United States)

    Alrahabi, Mothanna

    2015-01-01

    We evaluated the use of NiTi rotary and stainless steel endodontic instruments for canal shaping by undergraduate students. We also assessed the quality of root canal preparation as well as the occurrence of iatrogenic events during instrumentation. In total, 30 third-year dental students attending Taibah University Dental College prepared 180 simulated canals in resin blocks with NiTi rotary instruments and stainless steel hand files. Superimposed images were prepared to measure the removal of material at different levels from apical termination using the GSA image analysis software. Preparation time, procedural accidents, and canal shape after preparation were analyzed using χ 2 and t-tests. The statistical significance level was set at P instruments and stainless steel files; the former was associated with shorter preparation time, less ledge formation (1.1% vs. 14.4%), and greater instrument fracture (5.56% vs. 1.1%). These results indicate that NiTi rotary instruments result in better canal geometry and cause less canal transportation. Manual instrumentation using stainless steel files is safer than rotary instrumentation for inexperienced students. Intensive preclinical training is a prerequisite for using NiTi rotary instruments. These results prompted us to reconsider theoretical and practical coursework when teaching endodontics.

  18. DJFS: Providing Highly Reliable and High‐Performance File System with Small‐Sized

    Directory of Open Access Journals (Sweden)

    Junghoon Kim

    2017-11-01

    Full Text Available File systems and applications try to implement their own update protocols to guarantee data consistency, which is one of the most crucial aspects of computing systems. However, we found that the storage devices are substantially under‐utilized when preserving data consistency because they generate massive storage write traffic with many disk cache flush operations and force‐unit‐access (FUA commands. In this paper, we present DJFS (Delta‐Journaling File System that provides both a high level of performance and data consistency for different applications. We made three technical contributions to achieve our goal. First, to remove all storage accesses with disk cache flush operations and FUA commands, DJFS uses small‐sized NVRAM for a file system journal. Second, to reduce the access latency and space requirements of NVRAM, DJFS attempts to journal compress the differences in the modified blocks. Finally, to relieve explicit checkpointing overhead, DJFS aggressively reflects the checkpoint transactions to file system area in the unit of the specified region. Our evaluation on TPC‐C SQLite benchmark shows that, using our novel optimization schemes, DJFS outperforms Ext4 by up to 64.2 times with only 128 MB of NVRAM.

  19. Operations Data Files, driving force behind International Space Station operations

    Science.gov (United States)

    Hoppenbrouwers, Tom; Ferra, Lionel; Markus, Michael; Wolff, Mikael

    2017-09-01

    Almost all tasks performed by the astronauts on-board the International Space Station (ISS) and by ground controllers in Mission Control Centre, from operation and maintenance of station systems to the execution of scientific experiments or high risk visiting vehicles docking manoeuvres, would not be possible without Operations Data Files (ODF). ODFs are the User Manuals of the Space Station and have multiple faces, going from traditional step-by-step procedures, scripts, cue cards, over displays, to software which guides the crew through the execution of certain tasks. Those key operational documents are standardized as they are used on-board the Space Station by an international crew constantly changing every 3 months. Furthermore this harmonization effort is paramount for consistency as the crew moves from one element to another in a matter of seconds, and from one activity to another. On ground, a significant large group of experts from all International Partners drafts, prepares reviews and approves on a daily basis all Operations Data Files, ensuring their timely availability on-board the ISS for all activities. Unavailability of these operational documents will halt the conduct of experiments or cancel milestone events. This paper will give an insight in the ground preparation work for the ODFs (with a focus on ESA ODF processes) and will present an overview on ODF formats and their usage within the ISS environment today and show how vital they are. Furthermore the focus will be on the recently implemented ODF features, which significantly ease the use of this documentation and improve the efficiency of the astronauts performing the tasks. Examples are short video demonstrations, interactive 3D animations, Execute Tailored Procedures (XTP-versions), tablet products, etc.

  20. ATLAS File and Dataset Metadata Collection and Use

    CERN Document Server

    Albrand, S; The ATLAS collaboration; Lambert, F; Gallas, E J

    2012-01-01

    The ATLAS Metadata Interface (“AMI”) was designed as a generic cataloguing system, and as such it has found many uses in the experiment including software release management, tracking of reconstructed event sizes and control of dataset nomenclature. The primary use of AMI is to provide a catalogue of datasets (file collections) which is searchable using physics criteria. In this paper we discuss the various mechanisms used for filling the AMI dataset and file catalogues. By correlating information from different sources we can derive aggregate information which is important for physics analysis; for example the total number of events contained in dataset, and possible reasons for missing events such as a lost file. Finally we will describe some specialized interfaces which were developed for the Data Preparation and reprocessing coordinators. These interfaces manipulate information from both the dataset domain held in AMI, and the run-indexed information held in the ATLAS COMA application (Conditions and ...

  1. 75 FR 4783 - Federal Consistency Appeal by Villa Marina Yacht Harbour, Inc.

    Science.gov (United States)

    2010-01-29

    ... DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Administration Federal Consistency Appeal by Villa Marina Yacht Harbour, Inc. AGENCY: National Oceanic and Atmospheric Administration (NOAA... days, closure of the decision record in an administrative appeal filed by Villa Marina Yacht Harbour...

  2. In vitro comparison rate of dental root canal transportation using two single file systems on the simulated resin blocks

    Directory of Open Access Journals (Sweden)

    Mohammad Javad Etesami

    2016-07-01

    Full Text Available Background and Aims: Cleaning and shaping is one of the most important stages in endodontic treatment. Single-file systems save time and reduce the risk of transmission of pathogens. This in vitro study was aimed to compare the rate of canal transportation after the preparation of the stimulated resin root canal with two single-file systems, namely Waveone and Reciproc. Materials and Methods: Thirty stimulated resin root canal blocks with size 8/0. 02 K file were randomly divided into two study groups. The preparation in Group A and Group B was performed using Reciproc and Waveone files, respectively. Pre and post- preparation photographs were taken and the images were superimposed to evaluate the inner and outer wall’s curvature tendency at three points (apical, middle and coronal using AutoCad pragram. Data were analyzed using T-test. Results: Based on the results, the degree of transportation in the inner and outer walls of the canal was less at the level of 3 millimeters (P0.05. Conclusion: Waveone showed better performance in the middle third of canal and this system maybe recommended.

  3. Microtomography-based comparison of reciprocating single-file F2 ProTaper technique versus rotary full sequence.

    Science.gov (United States)

    Paqué, Frank; Zehnder, Matthias; De-Deus, Gustavo

    2011-10-01

    A preparation technique with only 1 single instrument was proposed on the basis of the reciprocating movement of the F2 ProTaper instrument. The present study was designed to quantitatively assess canal preparation outcomes achieved by this technique. Twenty-five extracted human mandibular first molars with 2 separate mesial root canals were selected. Canals were randomly assigned to 1 of the 2 experimental groups: group 1, rotary conventional preparation by using ProTaper, and group 2, reciprocate instrumentation with 1 single ProTaper F2 instrument. Specimens were scanned initially and after root canal preparation with an isotropic resolution of 20 μm by using a micro-computed tomography system. The following parameters were assessed: changes in dentin volume, percentage of shaped canal walls, and degree of canal transportation. In addition, the time required to reach working length with the F2 instrument was recorded. Preoperatively, there were no differences regarding root canal curvature and volume between experimental groups. Overall, instrumentation led to enlarged canal shapes with no evidence of preparation errors. There were no statistical differences between the 2 preparation techniques in the anatomical parameters assessed (P > .01), except for a significantly higher canal transportation caused by the reciprocating file in the coronal canal third. On the other hand, preparation was faster by using the single-file technique (P ProTaper technique and conventional ProTaper full-sequence rotary approach were similar. However, the single-file F2 ProTaper technique was markedly faster in reaching working length. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  4. Comparison of Single Visit Post Endodontic Pain Using Mtwo Rotary and Hand K-File Instruments: A Randomized Clinical Trial.

    Science.gov (United States)

    Kashefinejad, Mohamad; Harandi, Azade; Eram, Saeed; Bijani, Ali

    2016-01-01

    Pain is an unpleasant outcome of endodontic treatment that can be unbearable to patients. Instrumentation techniques may affect the frequency and intensity of post-endodontic pain. This study aimed to compare single visit post endodontic pain using Mtwo (NiTi) rotary and hand K-file instruments. In this randomized controlled trial, 60 teeth with symptomatic irreversible pulpitis in 53 patients were selected and randomly assigned into two groups of 30 teeth. In group A, the root canals were prepared with Mtwo (NiTi) rotary instruments. In group B, the root canals were prepared with hand K-file instruments. Pain assessment was implemented using visual analog scale (VAS) at four, eight, 12 and 24 hours after treatment. The acquired data were analyzed using chi-square, Mann-Whitney U and Student's t-test (Protary instruments experienced significantly less post-endodontic pain than those treated with hand instruments (Protary instruments in root canal preparation contributed to lower incidence of postoperative pain than hand K-files.

  5. Comparison of canal transportation and centering ability of twisted files, Pathfile-ProTaper system, and stainless steel hand K-files by using computed tomography.

    Science.gov (United States)

    Gergi, Richard; Rjeily, Joe Abou; Sader, Joseph; Naaman, Alfred

    2010-05-01

    The purpose of this study was to compare canal transportation and centering ability of 2 rotary nickel-titanium (NiTi) systems (Twisted Files [TF] and Pathfile-ProTaper [PP]) with conventional stainless steel K-files. Ninety root canals with severe curvature and short radius were selected. Canals were divided randomly into 3 groups of 30 each. After preparation with TF, PP, and stainless steel files, the amount of transportation that occurred was assessed by using computed tomography. Three sections from apical, mid-root, and coronal levels of the canal were recorded. Amount of transportation and centering ability were assessed. The 3 groups were statistically compared with analysis of variance and Tukey honestly significant difference test. Less transportation and better centering ability occurred with TF rotary instruments (P < .0001). K-files showed the highest transportation followed by PP system. PP system showed significant transportation when compared with TF (P < .0001). The TF system was found to be the best for all variables measured in this study. Copyright (c) 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  6. Overview of Site Preparation

    International Nuclear Information System (INIS)

    Garin, P.

    2006-01-01

    The preparation of Cadarache as the host of ITER is organised at a double level: Europe, since the beginning of the candidature in 2001, is coordinating the so-called European ITER Site Studies; France, as the host country, has put in place a dedicated structure at a decisional level (close to the government), and operational level in the PACA region with two entities: The Agency Iter France (AIF), inside the CEA, interlocutor of international and European entities, in charge of site preparation and fund recollection; An accompanying prefectoral mission, in charge mainly of road adaptation and the international school. The paper will cover all the aspects related to the preparation of the implementation of ITER: Technical aspects: the progress of site preparation itself, its servicing (water supply, electrical supply, Internet...), the road adaptation between the large harbour of Fos-sur-mer and Cadarache, etc. will be detailed. Regulatory procedures: in the framework of the delegation that the ITER partners gave to the CEA/AIF on 14 th September 2005, two main large files are in progress: The public debate, organised by an independent authority, informs the population of the challenges and impacts of ITER in Provence; The safety documents: the writing of the preliminary safety report, which will be submitted to the Nuclear Safety Authority and the files submitted to the public during the public enquiries are ongoing. Socioeconomic aspects: the welcome of ITER staff and their families is operational, via a dedicated Welcome Office; the location of an international school in Manosque leads now to its pre-figuration. The overall organisation will be described, as well as all planning forecast for the coming years, leading to the start of construction. (author)

  7. Screw-in forces during instrumentation by various file systems.

    Science.gov (United States)

    Ha, Jung-Hong; Kwak, Sang Won; Kim, Sung-Kyo; Kim, Hyeon-Cheol

    2016-11-01

    The purpose of this study was to compare the maximum screw-in forces generated during the movement of various Nickel-Titanium (NiTi) file systems. Forty simulated canals in resin blocks were randomly divided into 4 groups for the following instruments: Mtwo size 25/0.07 (MTW, VDW GmbH), Reciproc R25 (RPR, VDW GmbH), ProTaper Universal F2 (PTU, Dentsply Maillefer), and ProTaper Next X2 (PTN, Dentsply Maillefer, n = 10). All the artificial canals were prepared to obtain a standardized lumen by using ProTaper Universal F1. Screw-in forces were measured using a custom-made experimental device (AEndoS- k , DMJ system) during instrumentation with each NiTi file system using the designated movement. The rotation speed was set at 350 rpm with an automatic 4 mm pecking motion at a speed of 1 mm/sec. The pecking depth was increased by 1 mm for each pecking motion until the file reach the working length. Forces were recorded during file movement, and the maximum force was extracted from the data. Maximum screw-in forces were analyzed by one-way ANOVA and Tukey's post hoc comparison at a significance level of 95%. Reciproc and ProTaper Universal files generated the highest maximum screw-in forces among all the instruments while M-two and ProTaper Next showed the lowest ( p files with smaller cross-sectional area for higher flexibility is recommended.

  8. Long term file migration. Part I: file reference patterns

    International Nuclear Information System (INIS)

    Smith, A.J.

    1978-08-01

    In most large computer installations, files are moved between on-line disk and mass storage (tape, integrated mass storage device) either automatically by the system or specifically at the direction of the user. This is the first of two papers which study the selection of algorithms for the automatic migration of files between mass storage and disk. The use of the text editor data sets at the Stanford Linear Accelerator Center (SLAC) computer installation is examined through the analysis of thirteen months of file reference data. Most files are used very few times. Of those that are used sufficiently frequently that their reference patterns may be examined, about a third show declining rates of reference during their lifetime; of the remainder, very few (about 5%) show correlated interreference intervals, and interreference intervals (in days) appear to be more skewed than would occur with the Bernoulli process. Thus, about two-thirds of all sufficiently active files appear to be referenced as a renewal process with a skewed interreference distribution. A large number of other file reference statistics (file lifetimes, interference distributions, moments, means, number of uses/file, file sizes, file rates of reference, etc.) are computed and presented. The results are applied in the following paper to the development and comparative evaluation of file migration algorithms. 17 figures, 13 tables

  9. [Comparison of effectiveness and safety between Twisted File technique and ProTaper Universal rotary full sequence based on micro-computed tomography].

    Science.gov (United States)

    Chen, Xiao-bo; Chen, Chen; Liang, Yu-hong

    2016-02-18

    To evaluate the efficacy and security of two type of rotary nickel titanium system (Twisted File and ProTaper Universal) for root canal preparation based on micro-computed tomography(micro-CT). Twenty extracted molars (including 62 canals) were divided into two experimental groups and were respectively instrumented using Twisted File rotary nickel titanium system (TF) and ProTaper Universal rotary nickel titanium system (PU) to #25/0.08 following recommended protocol. Time for root canal instrumentation (accumulation of time for every single file) was recorded. The 0-3 mm root surface from apex was observed under an optical stereomicroscope at 25 × magnification. The presence of crack line was noted. The root canals were scanned with micro-CT before and after root canal preparation. Three-dimensional shape images of canals were reconstructed, calculated and evaluated. The amount of canal central transportation of the two groups was calculated and compared. The shorter preparation time [(0.53 ± 0.14) min] was observed in TF group, while the preparation time of PU group was (2.06 ± 0.39) min (Pvs. (0.097 ± 0.084) mm, P<0.05]. No instrument separation was observed in both the groups. Cracks were not found in both the groups either based in micro-CT images or observation under an optical stereomicroscope at 25 × magnification. Compared with ProTaper Universal, Twisted File took less time in root canal preparation and exhibited better shaping ability, and less canal transportation.

  10. Preparation of CuIn1-xGaxS2 (x = 0.5) flowers consisting of nanoflakes via a solvothermal method

    International Nuclear Information System (INIS)

    Liang Xiaojuan; Zhong Jiasong; Yang Fan; Hua Wei; Jin Huaidong; Liu Haitao; Sun Juncai; Xiang Weidong

    2011-01-01

    Highlights: → We report for the first time a small biomolecule-assisted route using L-cysteine as sulfur source and complexing agent to synthesis CuIn 0.5 Ga 0.5 S 2 crystals. → The possible mechanisms leading to CuIn 0.5 Ga 0.5 S 2 flowers consisting of nanoflakes were proposed. → In addition, the morphology, structure, and phase composition of the as-prepared CuIn 0.5 Ga 0.5 S 2 products were investigated in detail by XRD, FESEM, EDS, XPS, TEM (HRTEM) and SAED. - Abstract: CuIn 1-x Ga x S 2 (x = 0.5) flowers consisting of nanoflakes were successfully prepared by a biomolecule-assisted solvothermal route at 220 deg. C for 10 h, employing copper chloride, gallium chloride, indium chloride and L-cysteine as precursors. The biomolecule L-cysteine acting as sulfur source was found to play a very important role in the formation of the final product. The diameter of the CuIn 0.5 Ga 0.5 S 2 flowers was 1-2 μm, and the thickness of the flakes was about 15 nm. The obtained products were characterized by X-ray diffraction (XRD), energy dispersion spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), field-emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), high-resolution transmission electron microscopy (HRTEM), selected area electron diffraction spectroscopy (SAED), and UV-vis absorption spectroscopy. The influences of the reaction temperature, reaction time, sulfur source and the molar ratio of Cu-to-L-cysteine (reactants) on the formation of the target compound were investigated. The formation mechanism of the CuIn 0.5 Ga 0.5 S 2 flowers consisting of flakes was discussed.

  11. Stability of Mixed Preparations Consisting of Commercial Moisturizing Creams with an Ointment Base Investigated by Magnetic Resonance Imaging.

    Science.gov (United States)

    Onuki, Yoshinori; Funatani, Chiaki; Yamamoto, Yoshihisa; Fukami, Toshiro; Koide, Tatsuo; Hayashi, Yoshihiro; Takayama, Kozo

    2017-01-01

    A moisturizing cream mixed with a steroid ointment is frequently prescribed to patients suffering from atopic dermatitis. However, there is a concern that the mixing operation causes destabilization. The present study was performed to investigate the stability of such preparations closely using magnetic resonance imaging (MRI). As sample preparations, five commercial moisturizing creams that are popular in Japan were mixed with an ointment base, a white petrolatum, at a volume ratio of 1 : 1. The mixed preparations were stored at 60°C to accelerate the destabilization processes. Subsequently, the phase separations induced by the storage test were monitored using MRI. Using advanced MR technologies including spin-spin relaxation time (T 2 ) mapping and MR spectroscopy, we successfully characterized the phase-separation behavior of the test samples. For most samples, phase separations developed by the bleeding of liquid oil components. From a sample consisting of an oil-in-water-type cream, Urepearl Cream 10%, a distinct phase-separation mode was observed, which was initiated by the aqueous component separating from the bottom part of the sample. The resultant phase separation was the most distinct among the test samples. To investigate the phase separation quantitatively and objectively, we conducted a histogram analysis on the acquired T 2 maps. The water-in-oil type creams were found to be much more stable after mixing with ointment base than those of oil-in-water type creams. This finding strongly supported the validity of the mixing operation traditionally conducted in pharmacies.

  12. Temperature increases on the external root surface during endodontic treatment using single file systems.

    Science.gov (United States)

    Özkocak, I; Taşkan, M M; Gökt Rk, H; Aytac, F; Karaarslan, E Şirin

    2015-01-01

    The aim of this study is to evaluate increases in temperature on the external root surface during endodontic treatment with different rotary systems. Fifty human mandibular incisors with a single root canal were selected. All root canals were instrumented using a size 20 Hedstrom file, and the canals were irrigated with 5% sodium hypochlorite solution. The samples were randomly divided into the following three groups of 15 teeth: Group 1: The OneShape Endodontic File no.: 25; Group 2: The Reciproc Endodontic File no.: 25; Group 3: The WaveOne Endodontic File no.: 25. During the preparation, the temperature changes were measured in the middle third of the roots using a noncontact infrared thermometer. The temperature data were transferred from the thermometer to the computer and were observed graphically. Statistical analysis was performed using the Kruskal-Wallis analysis of variance at a significance level of 0.05. The increases in temperature caused by the OneShape file system were lower than those of the other files (P file showed the highest temperature increases. However, there were no significant differences between the Reciproc and WaveOne files. The single file rotary systems used in this study may be recommended for clinical use.

  13. PKA spectrum file

    Energy Technology Data Exchange (ETDEWEB)

    Kawai, M. [Toshiba Corp., Kawasaki, Kanagawa (Japan). Nuclear Engineering Lab.

    1997-03-01

    In the Japanese Nuclear Data Committee, the PKA/KERMA file containing PKA spectra, KERMA factors and DPA cross sections in the energy range between 10{sup -5} eV and 50 MeV is being prepared from the evaluated nuclear data. The processing code ESPERANT was developed to calculate quantities of PKA, KERMA and DPA from evaluated nuclear data for medium and heavy elements by using the effective single particle emission approximation (ESPEA). For light elements, the PKA spectra are evaluated by the SCINFUL/DDX and EXIFON codes, simultaneously with other neutron cross sections. The DPA cross sections due to charged particle emitted from light elements are evaluated for high neutron energy above 20 MeV. (author)

  14. A brief overview of the European Fusion File (EFF) project

    International Nuclear Information System (INIS)

    Kellett, M.A.; Forrest, R.A.; Batistoni, P.

    2003-01-01

    The European Fusion File (EFF) Project is a collaborative project with work funded by the European Fusion Development Agreement (EFDA). The emphasis is on the pooling of resources and removal of duplication of effort, leading to the efficient development of two types of nuclear data libraries for use in fusion power plant design and operation studies. The two branches consist of, on the one hand, a transport file for modelling and design capabilities and, secondly, an activation file for the calculation and simulation of dose rates and energy release during operation of a future power plant. The OECD Nuclear Energy Agency's Data Bank acts as the central repository for the files and all information discussed during twice yearly meetings. It offers its services at no charge to the Project. (author)

  15. A brief overview of the European Fusion File (EFF) project

    International Nuclear Information System (INIS)

    Kellett, M.A.

    2002-01-01

    The European Fusion File (EFF) Project is a collaborative project with work funded by the European Fusion Development Agreement (EFDA). The emphasis is on the pooling of resources and removal of duplication of effort, leading to the efficient development of two types of nuclear data libraries for use in fusion reactor design and operation work. The two branches consist of, on the one hand, a transport file for modelling and design capabilities and, secondly, an activation file for the calculation and simulation of dose rates and energy release during operation of a future reactor. The OECD Nuclear Energy Agency's Data Bank acts as the central repository for the files and all information discussed during twice yearly meetings, which it holds, offering its services at no charge to the Project. (author)

  16. Canal shaping of different single-file systems in curved root canals

    Directory of Open Access Journals (Sweden)

    Maurizio D'Amario

    2017-12-01

    Full Text Available Background/Purpose: This study compared maintenance of canal anatomy, occurrence of apical transportation, and working time observed after instrumentation with One Shape New Generation rotary system (Micro-Mega, with those observed after instrumentation with Reciproc (VDW and WaveOne (Dentsply-Maillefer reciprocating systems. Materials and methods: The mesial canals of 45 mandibular molars (curvature angles between 35° and 45° were selected. Specimens were randomly divided into three groups, and canal preparations were performed using One Shape, Reciproc, or WaveOne systems (size #25. A digital double radiographic technique was used to determine apical transportation and change in angle of curvature. Also, working time and instrument failures were recorded. Data were statistically analyzed. Results: During preparation, no file fractured. No statistically significant differences were found among groups. No system showed a significantly faster preparation time than others (P>0.05. All instruments maintained the original canal curvature well and were safe to use. Conclusion: Both continuous rotary instrument and reciprocating systems did not have any influence on the presence of apical transportation or caused an alteration in angle of canal curvature. Keywords: canal curvature, canal straightening, endodontics, reciprocating motion, single file instrumentation

  17. 17 CFR 202.2 - Pre-filing assistance and interpretative advice.

    Science.gov (United States)

    2010-04-01

    ... filings with the Commission may receive advice of a general nature as to the preparation thereof..., except in connection with matters under the Public Utility Holding Company Act of 1935 and certain matters under the Investment Company Act of 1940, at one of its regional offices. [25 FR 6736, July 15...

  18. DataNet: A flexible metadata overlay over file resources

    CERN Multimedia

    CERN. Geneva

    2014-01-01

    Managing and sharing data stored in files results in a challenge due to data amounts produced by various scientific experiments [1]. While solutions such as Globus Online [2] focus on file transfer and synchronization, in this work we propose an additional layer of metadata over file resources which helps to categorize and structure the data, as well as to make it efficient in integration with web-based research gateways. A basic concept of the proposed solution [3] is a data model consisting of entities built from primitive types such as numbers, texts and also from files and relationships among different entities. This allows for building complex data structure definitions and mix metadata and file data into a single model tailored for a given scientific field. A data model becomes actionable after being deployed as a data repository which is done automatically by the proposed framework by using one of the available PaaS (platform-as-a-service) platforms and is exposed to the world as a REST service, which...

  19. JENDL special purpose file

    International Nuclear Information System (INIS)

    Nakagawa, Tsuneo

    1995-01-01

    In JENDL-3,2, the data on all the reactions having significant cross section over the neutron energy from 0.01 meV to 20 MeV are given for 340 nuclides. The object range of application extends widely, such as the neutron engineering, shield and others of fast reactors, thermal neutron reactors and nuclear fusion reactors. This is a general purpose data file. On the contrary to this, the file in which only the data required for a specific application field are collected is called special purpose file. The file for dosimetry is a typical special purpose file. The Nuclear Data Center, Japan Atomic Energy Research Institute, is making ten kinds of JENDL special purpose files. The files, of which the working groups of Sigma Committee are in charge, are listed. As to the format of the files, ENDF format is used similarly to JENDL-3,2. Dosimetry file, activation cross section file, (α, n) reaction data file, fusion file, actinoid file, high energy data file, photonuclear data file, PKA/KERMA file, gas production cross section file and decay data file are described on their contents, the course of development and their verification. Dosimetry file and gas production cross section file have been completed already. As for the others, the expected time of completion is shown. When these files are completed, they are opened to the public. (K.I.)

  20. Topographic Features of Five K-file Brands in Iranian Market: A Scanning Electron Microscopic Study.

    Science.gov (United States)

    Shahravan, Arash; Gorjestani, Hedayat; Izadi, Arash; Mortazavi, Nazanin

    2018-01-01

    Endodontic files which are used to clean and shape the root canal space differ from each other regarding technical specifications. Recently, K-type files are repeatedly studied on their cutting efficiency. This study aims to evaluate the tip design and cutting efficiency of 5 brands of K-files, available in Iran dental market (naming Dentsply, Thomas, Mani, Perfect and Larmrose). In this descriptive study, topographic features of file tips were investigated by the scanning electron microscope (SEM). Those features included tip symmetry, tip design, tip angle, and the distance from the tip to the lowest flute. SEM images (×250 magnification) of files were prepared. Statistical tests (Fisher's exact test, Chi -square, ANOVA, and t test) were used and P brands. No significant differences were found with respect to distance from the file tip to the lowermost flute between different file brands of this study ( P =0.2, One way ANOVA). Dentsply and Mani files possessed the most symmetrical tips and greatest tip angles. With respect to tip length, all 5 brands were satisfactory. However, neither of 5 brands evaluated topographically were outstanding in every aspect.

  1. Archive of Census Related Products (ACRP): 1992 Boundary Files

    Data.gov (United States)

    National Aeronautics and Space Administration — The 1992 Boundary Files portion of the Archive of Census Related Products (ACRP) consists of 1992 boundary data from the U.S. Census Bureau's Topologically...

  2. PHOBINS: an index file of photon production cross section data and its utility code system

    International Nuclear Information System (INIS)

    Hasegawa, Akira; Koyama, Kinji; Ido, Masaru; Hotta, Masakazu; Miyasaka, Shun-ichi

    1978-08-01

    The code System PHOBINS developed for reference of photon production cross sections is described in detail. The system is intended to grasp the present status of photon production data and present the information of available data. It consists of four utility routines, CREA, UP-DT, REF and BACK, and data files. These utility routines are used for making an index file of the photon production cross sections, updating the index file, searching the index file and producing a back-up file of the index file. In the index file of the photon production cross sections, a data base system is employed for efficient data management in economical storage, ease of updating and efficient reference. The present report is a reference manual of PHOBINS. (author)

  3. Shaping ability of single-file reciprocating and heat-treated multifile rotary systems: a micro-CT study.

    Science.gov (United States)

    Marceliano-Alves, M F V; Sousa-Neto, M D; Fidel, S R; Steier, L; Robinson, J P; Pécora, J D; Versiani, M A

    2015-12-01

    To investigate changes in three-dimensional geometry, in various cross-sectional morphological parameters and in the centring ability of root canals prepared with different preparation systems using microcomputed tomographic imaging technology. Sixty-four mesial canals of mandibular molars were matched based on similar morphological dimensions using micro-CT evaluation and assigned to four experimental groups (n = 16), according to the canal preparation technique: Reciproc, WaveOne, Twisted File and HyFlex CM systems. Changes in several 2D (area, perimeter, form factor, roundness, minor and major diameter) and 3D [volume, surface area, structure model index (SMI)] morphological parameters, as well as canal transportation, were compared with preoperative values using Kruskal-Wallis and anovapost hoc Tukey's tests with the significance level set at 5%. Preparation significantly increased all tested parameters in the experimental groups. No significant differences were observed between groups regarding changes in volume, surface area, SMI, form factor and roundness of the root canal after preparation (P > 0.05). In the apical third, the Reciproc group had significantly greater changes in canal area, perimeter, major and minor diameters than the other groups (P File and HyFlex CM systems were associated with significantly less transportation than the reciprocating instruments, Reciproc and WaveOne (P File and HyFlex CM systems were able to maintain the original canal anatomy with less canal transportation than Reciproc and WaveOne; however, these differences are unlikely to be of clinical significance. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  4. A comparative evaluation of gutta percha removal and extrusion of apical debris by rotary and hand files.

    Science.gov (United States)

    Chandrasekar; Ebenezar, A V Rajesh; Kumar, Mohan; Sivakumar, A

    2014-11-01

    The aim of this study was to evaluate the efficacy of Protaper retreatment files in comparison with RaCe, K3 and H-files for removal of gutta-percha and apically extruded debris using volumetric analysis. Forty extracted single rooted maxillary incisor teeth with straight canals and mature apices were selected for the study. After access cavity preparation, apical patency was confirmed with a size 10 K-file extending 1mm beyond the point at which it was first visible at the apical end. Working lengths were determined with the use of size 15 K-file. The canals were prepared in a step-back technique and the master apical file was size 30 for all teeth. 3% sodium hypochlorite was used as an irrigant after each instrumentation. Before final rinse, size 20 K-file was passed 1mm beyond the apex to remove any dentinal shaving plugs and maintain the apical patency. Then the canals were dried with paper points. The root canal was filled using standard gutta-percha points and zinc oxide eugenol sealer under lateral condensation technique. The teeth were then randomly divided into four groups of ten teeth each based on the instrument used for gutta percha removal. All the rotary instruments used in this study were rotated at 300rpm. The instruments used were: Group 1 - RaCe Files, Group 2 - ProTaper retreatment Files, Group 3 - K3 Files and Group 4 - H Files. The volume of the obturating material was calculated before and after removal using volumetric analysis with spiral CT. The removal efficacy with each instrument was calculated and statistically analysed. The results of the study show that the ProTaper retreatment files (Group 2) (97.4%) showed the highest efficiency in the removal of obturating material, which was followed by RaCe (95.74%), K3 (92.86%) and H files (90.14%) with the efficiency in the decreasing order. Similarly the mean apical extrusion in H files (0.000 ± 0.002) was significantly lower than all the rotary instruments. However, the difference among the

  5. Preparation of multi-layer film consisting of hydrogen-free DLC and nitrogen-containing DLC for conductive hard coating

    Science.gov (United States)

    Iijima, Yushi; Harigai, Toru; Isono, Ryo; Degai, Satoshi; Tanimoto, Tsuyoshi; Suda, Yoshiyuki; Takikawa, Hirofumi; Yasui, Haruyuki; Kaneko, Satoru; Kunitsugu, Shinsuke; Kamiya, Masao; Taki, Makoto

    2018-01-01

    Conductive hard-coating films have potential application as protective films for contact pins used in the electrical inspection process for integrated circuit chips. In this study, multi-layer diamond-like carbon (DLC) films were prepared as conductive hard-coating films. The multi-layer DLC films consisting of DLC and nitrogen-containing DLC (N-DLC) film were prepared using a T-shape filtered arc deposition method. Periodic DLC/N-DLC four-layer and eight-layer films had the same film thickness by changing the thickness of each layer. In the ball-on-disk test, the N-DLC mono-layer film showed the highest wear resistance; however, in the spherical polishing method, the eight-layer film showed the highest polishing resistance. The wear and polishing resistance and the aggressiveness against an opponent material of the multi-layer DLC films improved by reducing the thickness of a layer. In multi-layer films, the soft N-DLC layer between hard DLC layers is believed to function as a cushion. Thus, the tribological properties of the DLC films were improved by a multi-layered structure. The electrical resistivity of multi-layer DLC films was approximately half that of the DLC mono-layer film. Therefore, the periodic DLC/N-DLC eight-layer film is a good conductive hard-coating film.

  6. 11 CFR 100.19 - File, filed or filing (2 U.S.C. 434(a)).

    Science.gov (United States)

    2010-01-01

    ... a facsimile machine or by electronic mail if the reporting entity is not required to file..., including electronic reporting entities, may use the Commission's website's on-line program to file 48-hour... the reporting entity is not required to file electronically in accordance with 11 CFR 104.18. [67 FR...

  7. Storage of sparse files using parallel log-structured file system

    Science.gov (United States)

    Bent, John M.; Faibish, Sorin; Grider, Gary; Torres, Aaron

    2017-11-07

    A sparse file is stored without holes by storing a data portion of the sparse file using a parallel log-structured file system; and generating an index entry for the data portion, the index entry comprising a logical offset, physical offset and length of the data portion. The holes can be restored to the sparse file upon a reading of the sparse file. The data portion can be stored at a logical end of the sparse file. Additional storage efficiency can optionally be achieved by (i) detecting a write pattern for a plurality of the data portions and generating a single patterned index entry for the plurality of the patterned data portions; and/or (ii) storing the patterned index entries for a plurality of the sparse files in a single directory, wherein each entry in the single directory comprises an identifier of a corresponding sparse file.

  8. 77 FR 3763 - Town of Canton; Notice of Preliminary Permit Application Accepted for Filing and Soliciting...

    Science.gov (United States)

    2012-01-25

    ... would consist of: (1) The 18-foot-high, 325- foot-long stone masonry Upper Collinsville dam with a crest.... Although the Commission strongly encourages electronic filing, documents may also be paper-filed. To paper...

  9. 49 CFR 564.5 - Information filing; agency processing of filings.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 6 2010-10-01 2010-10-01 false Information filing; agency processing of filings... HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION REPLACEABLE LIGHT SOURCE INFORMATION (Eff. until 12-01-12) § 564.5 Information filing; agency processing of filings. (a) Each manufacturer...

  10. The effects of different nickel-titanium instruments on dentinal microcrack formations during root canal preparation.

    Science.gov (United States)

    Ustun, Yakup; Aslan, Tugrul; Sagsen, Burak; Kesim, Bertan

    2015-01-01

    The aim of the present study was to investigate the incidence of dentinal microcracks caused by different preparation techniques. 120 extracted human mandibular incisor teeth were divided into five experimental groups and one control group (n = 20): Group 1: Hand preparation with balanced force technique up to #25 K-file. Group 2: Preparation with only ProTaper F2 instrument in a reciprocating movement. Group 3: Preparation with Reciproc R25 instrument in a reciprocating movement. Group 4: Preparation with ProTaper instruments up to F2 instrument. Group 5: Preparation with ProTaper Next instruments up to X2 instrument. No procedure was applied to control group. The roots were sectioned horizontally at 3, 6 and 9 mm from the apex and examined. Absence or presence of dentinal microcracks was noted. The Chi-square test was performed to compare the appearance of cracked roots between all groups. There were no significant differences among the groups (P > 0.05). In conclusion, except the hand file and control group, all experimental groups showed microcrack formations.

  11. Cut-and-Paste file-systems: integrating simulators and file systems

    NARCIS (Netherlands)

    Bosch, H.G.P.; Mullender, Sape J.

    1995-01-01

    We have implemented an integrated and configurable file system called the Pegasus filesystem (PFS) and a trace-driven file-system simulator called Patsy. Patsy is used for off-line analysis of file-systemalgorithms, PFS is used for on-line file-systemdata storage. Algorithms are first analyzed in

  12. 26 CFR 1.6696-1 - Claims for credit or refund by tax return preparers or appraisers.

    Science.gov (United States)

    2010-04-01

    ... THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Additions to the Tax, Additional Amounts.... (a) Notice and demand. (1) The Internal Revenue Service (IRS) shall issue to each tax return preparer... issued to the tax return preparer. (2) A tax return preparer may file one or more consolidated claims for...

  13. Effect of coronal flaring on apical extrusion of debris during root canal instrumentation using single-file systems.

    Science.gov (United States)

    Topçuoğlu, H S; Üstün, Y; Akpek, F; Aktı, A; Topçuoğlu, G

    2016-09-01

    To evaluate the effect of coronal flaring on the amount of debris extruded apically during root canal preparation using the Reciproc, WaveOne (WO) and OneShape (OS) single-file systems. Ninety extracted single-rooted mandibular incisor teeth were randomly assigned to six groups (n = 15 for each group) for canal instrumentation. Endodontic access cavities were prepared in each tooth. In three of the six groups, coronal flaring was not performed; coronal flaring was performed with Gates-Glidden drills on all teeth in the remaining three groups. The canals were then instrumented with one or other of the following single-file instrument systems: Reciproc, WO and OS. Debris extruded apically during instrumentation was collected into pre-weighed Eppendorf tubes. The tubes were then stored in an incubator at 70 °C for 5 days. The weight of the dry extruded debris was established by subtracting the pre-instrumentation and post-instrumentation weight of the Eppendorf tubes for each group. Data were analysed using one-way analysis of variance (anova) and Tukey's post hoc tests (P = 0.05). Reciproc and WO files without coronal flaring produced significantly more debris compared with the other groups (P  0.05). All single-file systems caused apical extrusion of debris. Performing coronal flaring prior to canal preparation reduced the amount of apically extruded debris when using Reciproc or WO systems. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  14. Glide path preparation in S-shaped canals with rotary pathfinding nickel-titanium instruments.

    Science.gov (United States)

    Ajuz, Natasha C C; Armada, Luciana; Gonçalves, Lucio S; Debelian, Gilberto; Siqueira, José F

    2013-04-01

    This study compared the incidence of deviation along S-shaped (double-curved) canals after glide path preparation with 2 nickel-titanium (NiTi) rotary pathfinding instruments and hand K-files. S-shaped canals from 60 training blocks were filled with ink, and preinstrumentation images were obtained by using a stereomicroscope. Glide path preparation was performed by an endodontist who used hand stainless steel K-files (up to size 20), rotary NiTi PathFile instruments (up to size 19), or rotary NiTi Scout RaCe instruments (up to size 20). Postinstrumentation images were taken by using exactly the same conditions as for the preinstrumentation images, and both pictures were superimposed. Differences along the S-shaped canal for the mesial and distal aspects were measured to evaluate the occurrence of deviation. Intragroup analysis showed that all instruments promoted some deviation in virtually all levels. Overall, regardless of the group, deviations were observed in the mesial wall at the canal terminus and at levels 4, 5, 6 and 7 mm and in the distal wall at levels 1, 2, and 3 mm. These levels corresponded to the inner walls of each curvature. Both rotary NiTi instruments performed significantly better than hand K-files at all levels (P instruments showed significantly better results than PathFiles at levels 0, 2, 3, 5, and 6 mm (P rotary NiTi instruments are suitable for adequate glide path preparation because they promoted less deviation from the original canal anatomy when compared with hand-operated instruments. Of the 2 rotary pathfinding instruments, Scout RaCe showed an overall significantly better performance. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  15. Preparation of a data bank system for isotope correlation on spent nuclear fuels

    International Nuclear Information System (INIS)

    Nakahara, Yoshinori; Umezawa, Hirokazu

    1981-11-01

    For the purposes of studying isotope correlation on spent nuclear fuels and its applicability to safeguards technology of nuclear material, a data bank system has been prepared on the basis of a FACOM M200 computer in JAERI. Spent fuels data of fabrication, irradiation history, reactor operator's burnup calculation, and reprocessing are stored in four kinds of data files: (1) Fuel assembly data file, (2) reprocessing batch data file, (3) plutonium product data file, and (4) uranium product data file. Corrections for decay and for mixing from adjoining batches are made and the corrected data are also kept in the files. A wide variety of variables may be derived from the isotopic and other data stored and subjected to optional statistical treatments such as regression analysis and paired comparison. Computer language used for the system was FORTRAN-IV. The system can be operated in a conversational mode with graphic indication, so that one may proceed such a statistical analysis immediately under various conditions of calculation. (author)

  16. Cut-and-Paste file-systems : integrating simulators and file systems

    NARCIS (Netherlands)

    Bosch, H.G.P.; Mullender, Sape J.

    1996-01-01

    We have implemented an integrated and configurable file system called the PFS and a trace-driven file-system simulator called Patsy. Patsy is used for off-line analysis of file-system algorithms, PFS is used for on-line file-system data storage. Algorithms are first analyzed in Patsy and when we are

  17. Problems in Learning of Electronic Filing at Vocational School in Yogyakarta Special Region, Indonesia

    Science.gov (United States)

    Sutirman; Muhyadi; Surjono, Herman Dwi

    2017-01-01

    This study aims to investigate the learning implementation of electronic filing and problems faced by teachers in learning implementing of electronic filing. This study is a descriptive research with qualitative approach. Collecting data used interview and documentation techniques. The research subjects consisted of 29 teachers who teach Filing…

  18. Activation cross section data file, (1)

    International Nuclear Information System (INIS)

    Yamamuro, Nobuhiro; Iijima, Shungo.

    1989-09-01

    To evaluate the radioisotope productions due to the neutron irradiation in fission of fusion reactors, the data for the activation cross sections ought to be provided. It is planning to file more than 2000 activation cross sections at final. In the current year, the neutron cross sections for 14 elements from Ni to W have been calculated and evaluated in the energy range 10 -5 to 20 MeV. The calculations with a simplified-input nuclear cross section calculation system SINCROS were described, and another method of evaluation which is consistent with the JENDL-3 were also mentioned. The results of cross section calculation are in good agreement with experimental data and they were stored in the file 8, 9 and 10 of ENDF/B format. (author)

  19. Effect of Autoclave Cycles on Surface Characteristics of S-File Evaluated by Scanning Electron Microscopy.

    Science.gov (United States)

    Razavian, Hamid; Iranmanesh, Pedram; Mojtahedi, Hamid; Nazeri, Rahman

    2016-01-01

    Presence of surface defects in endodontic instruments can lead to unwanted complications such as instrument fracture and incomplete preparation of the canal. The current study was conducted to evaluate the effect of autoclave cycles on surface characteristics of S-File by scanning electron microscopy (SEM). In this experimental study, 17 brand new S-Files (#30) were used. The surface characteristics of the files were examined in four steps (without autoclave, 1 autoclave cycle, 5 autoclave cycles and 10 autoclave cycles) by SEM under 200× and 1000× magnifications. Data were analyzed using the SPSS software and the paired sample t-test, independent sample t-test and multifactorial repeated measures ANOVA. The level of significance was set at 0.05. New files had debris and pitting on their surfaces. When the autoclave cycles were increased, the mean of surface roughness also increased at both magnifications (Pautoclave increased the surface roughness of the files and this had was directly related to the number of autoclave cycles.

  20. The ability of different nickel-titanium rotary instruments to induce dentinal damage during canal preparation

    NARCIS (Netherlands)

    Bier, C.A.S.; Shemesh, H.; Tanomaru-Filho, M.; Wesselink, P.R.; Wu, M.K.

    2009-01-01

    The purpose of this study was to compare the incidence of dentinal defects (fractures and craze lines) after canal preparation with different nickel-titanium rotary files. Two hundred sixty mandibular premolars were selected. Forty teeth were left unprepared (n = 40). The other teeth were prepared

  1. 14 CFR 16.13 - Filing of documents.

    Science.gov (United States)

    2010-01-01

    ... knowledge, information, and belief, the document is— (1) Consistent with this part; (2) Warranted by existing law or that a good faith argument exists for extension, modification, or reversal of existing law... proceeding. If any of these items change during the proceeding, the person shall promptly file notice of the...

  2. Review of uncertainty files and improved multigroup cross section files for FENDL

    International Nuclear Information System (INIS)

    Ganesan, S.

    1994-03-01

    The IAEA Nuclear Data Section, in co-operation with several national nuclear data centers and research groups, is creating an internationally available Fusion Evaluated Nuclear Data Library (FENDL), which will serve as a comprehensive source of processed and tested nuclear data tailored to the requirements of the Engineering and Development Activities (EDA) of the International Thermonuclear Experimental Reactor (ITER) Project and other fusion-related development projects. The FENDL project of the International Atomic Energy Agency has the task of coordination with the goal of assembling, processing and testing a comprehensive, fusion-relevant Fusion Evaluated Nuclear Data Library with unrestricted international distribution. The present report contains the summary of the IAEA Advisory Group Meeting on ''Review of Uncertainty Files and Improved Multigroup Cross Section Files for FENDL'', held during 8-12 November 1993 at the Tokai Research Establishment, JAERI, Japan, organized in cooperation with the Japan Atomic Energy Research Institute. The report presents the current status of the FENDL activity and the future work plans in the form of conclusions and recommendations of the four Working Groups of the Advisory Group Meeting on (1) experimental and calculational benchmarks, (2) preparation processed libraries for FENDL/ITER, (3) specifying procedures for improving FENDL and (4) selection of activation libraries for FENDL. (author). 1 tab

  3. Evaluation of the Self-Adjusting File system (SAF) for the instrumentation of primary molar root canals: a micro-computed tomographic study.

    Science.gov (United States)

    Kaya, E; Elbay, M; Yiğit, D

    2017-06-01

    The Self-Adjusting File (SAF) system has been recommended for use in permanent teeth since it offers more conservative and effective root-canal preparation when compared to traditional rotary systems. However, no study had evaluated the usage of SAF in primary teeth. The aim of this study was to evaluate and compare the use of SAF, K file (manual instrumentation) and Profile (traditional rotary instrumentation) systems for primary-tooth root-canal preparation in terms of instrumentation time and amounts of dentin removed using micro-computed tomography (μCT) technology. Study Design: The study was conducted with 60 human primary mandibular second molar teeth divided into 3 groups according to instrumentation technique: Group I: SAF (n=20); Group II: K file (n=20); Group III; Profile (n=20). Teeth were embedded in acrylic blocks and scanned with a μCT scanner prior to instrumentation. All distal root canals were prepared up to size 30 for K file,.04/30 for Profile and 2 mm thickness, size 25 for SAF; instrumentation time was recorded for each tooth, and a second μCT scan was performed after instrumentation was complete. Amounts of dentin removed were measured using the three-dimensional images by calculating the difference in root-canal volume before and after preparation. Data was statistically analysed using the Kolmogorov-Smirnov and Kruskal-Wallis tests. Manual instrumentation (K file) resulted in significantly more dentin removal when compared to rotary instrumentation (Profile and SAF), while the SAF system generated significantly less dentin removal than both manual instrumentation (K file) and traditional rotary instrumentation (Profile) (psystems. Within the experimental conditions of the present study, the SAF seems as a useful system for root-canal instrumentation in primary molars because it removed less dentin than other systems, which is especially important for the relatively thin-walled canals of primary teeth, and because it involves less

  4. A brief overview of the European Fusion File (EFF) Project

    International Nuclear Information System (INIS)

    Kellett, M.A.; Forrest, R.A.; Batistoni, P.

    2004-01-01

    The European Fusion File (EFF) Project is a collaborative project with work funded by the European Fusion Development Agreement (EFDA). The emphasis is on the pooling of resources and removal of duplication of effort, leading to the efficient development of two types of nuclear data libraries for use in fusion power plant design and operation studies. The two branches consist of, on the one hand, a general purpose file for modelling and design capabilities and, second, an activation file for the calculation and simulation of dose rates and energy release during operation of a future power plant. Efforts are directed towards a continued improvement of the quality of the nuclear data needed for these analyses. The OECD Nuclear Energy Agency's Data Bank acts as the central repository for the files and all information discussed during twice yearly meetings. It offers its services at no charge to the Project. (author)

  5. File sharing

    NARCIS (Netherlands)

    van Eijk, N.

    2011-01-01

    File sharing’ has become generally accepted on the Internet. Users share files for downloading music, films, games, software etc. In this note, we have a closer look at the definition of file sharing, the legal and policy-based context as well as enforcement issues. The economic and cultural

  6. 12 CFR 620.2 - Preparing and filing the reports.

    Science.gov (United States)

    2010-01-01

    ... annual and quarterly financial statements on a combined or consolidated basis shall also include in the...: (a) Copies of each report required by this part, including financial statements and related schedules... from accounting policies of the combined or consolidated statements. (2) Any bank that prepares its...

  7. SLIB77, Source Library Data Compression and File Maintenance System

    International Nuclear Information System (INIS)

    Lunsford, A.

    1989-01-01

    Description of program or function: SLIB77 is a source librarian program designed to maintain FORTRAN source code in a compressed form on magnetic disk. The program was prepared to meet program maintenance requirements for ongoing program development and continual improvement of very large programs involving many programmers from a number of different organizations. SLIB77 automatically maintains in one file the source of the current program as well as all previous modifications. Although written originally for FORTRAN programs, SLIB77 is suitable for use with data files, text files, operating systems, and other programming languages, such as Ada, C and COBOL. It can handle libraries with records of up to 160-characters. Records are grouped into DECKS and assigned deck names by the user. SLIB77 assigns a number to each record in each DECK. Records can be deleted or restored singly or as a group within each deck. Modification records are grouped and assigned modification identification names by the user. The program assigns numbers to each new record within the deck. The program has two modes of execution, BATCH and EDIT. The BATCH mode is controlled by an input file and is used to make changes permanent and create new library files. The EDIT mode is controlled by interactive terminal input and a built-in line editor is used for modification of single decks. Transferring of a library from one computer system to another is accomplished using a Portable Library File created by SLIB77 in a BATCH run

  8. The INDC/NEANDC joint discrepancy file 1990

    International Nuclear Information System (INIS)

    Patrick, B.H.; Kocherov, N.P.

    1990-06-01

    The International Nuclear Data Committee (INDC) and the Nuclear Energy Agency Nuclear Data Committee (NEANDC) maintain a close interest in nuclear data which exhibit discrepancies and, by making known the details of the disagreements, encouragement is given to the undertaking of new measurements as a means of eliminating the ambiguities. The previous discrepancy file was published by NEANDC and INDC in 1984. This document contains 10 papers and a separate abstract was prepared for each of them. Refs, figs and tabs

  9. Summary of JENDL-2 general purpose file

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, Tsuneo [ed.

    1984-06-15

    The general purpose file of the second version of Japanese Evaluated Nuclear Data Library (JENDL-2) was released in December 1982. Recently, descriptive data were added to JENDL-2 and at the same time the first revision of numerical data was performed. JENDL-2 (Rev.1) consists of the data for 89 nuclides and about 211,000 records in the ENDF/B-IV format. In this report, full listings of presently added descriptive data are given to summarize the JENDL-2 general purpose file. The 2200-m/sec and 14-MeV cross sections, resonance integrals, Maxwellian and fission spectrum averaged cross sections are given in a table. Average cross sections were also calculated in suitable energy intervals.

  10. Summary of JENDL-2 general purpose file

    International Nuclear Information System (INIS)

    Nakagawa, Tsuneo

    1984-06-01

    The general purpose file of the second version of Japanese Evaluated Nuclear Data Library (JENDL-2) was released in December 1982. Recently, descriptive data were added to JENDL-2 and at the same time the first revision of numerical data was performed. JENDL-2 (Rev1) consists of the data for 89 nuclides and about 211,000 records in the ENDF/B-IV format. In this report, full listings of presently added descriptive data are given to summarize the JENDL-2 general purpose file. The 2200-m/sec and 14-MeV cross sections, resonance integrals, Maxwellian and fission spectrum averaged cross sections are given in a table. Average cross sections were also calculated in suitable energy intervals. (author)

  11. Overview of the contents of ENDF/B-VI [Evaluated Nuclear Data File

    International Nuclear Information System (INIS)

    Dunford, C.L.; Pearlstein, S.

    1989-01-01

    The sixth release of the Evaluated Nuclear Data File (ENDF/B-VI) is now being prepared for general distribution. This data file serves as the primary source of nuclear data for nuclear applications in the United States and Canada and in many other countries of the world. The data library is maintained and distributed by the National Nuclear Data Center at Brookhaven National Laboratory from evaluations provided by members of the Cross Section Evaluation Working Group (CSEWG). Unlike its predecessor, ENDF/B-V, this file will be available to all requesters without restrictions. Compared to ENDF/B-V, released more than 11 yr ago, the ENDF/B-VI data library contains significant improvements for both fission and fusion reaction design. Future work will continue with limited staffing and foreign cooperation to provide the data needed for future nuclear applications

  12. 76 FR 72699 - KC Hydro LLC of New Hampshire; Notice of Preliminary Permit Application Accepted for Filing and...

    Science.gov (United States)

    2011-11-25

    .... The proposed project would consist of: (1) The existing 156-foot- long, 19-foot-high Milton stone.... Although the Commission strongly encourages electronic filing, documents may also be paper-filed. To paper...

  13. Comparison of Single Visit Post Endodontic Pain Using Mtwo Rotary and Hand K-File Instruments: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Mohamad Kashefinejad

    2016-08-01

    Full Text Available Objectives: Pain is an unpleasant outcome of endodontic treatment that can be unbearable to patients. Instrumentation techniques may affect the frequency and intensity of post-endodontic pain. This study aimed to compare single visit post endodontic pain using Mtwo (NiTi rotary and hand K-file instruments.Materials and Methods: In this randomized controlled trial, 60 teeth with symptomatic irreversible pulpitis in 53 patients were selected and randomly assigned into two groups of 30 teeth. In group A, the root canals were prepared with Mtwo (NiTi rotary instruments. In group B, the root canals were prepared with hand K-file instruments. Pain assessment was implemented using visual analog scale (VAS at four, eight, 12 and 24 hours after treatment. The acquired data were analyzed using chi-square, Mann-Whitney U and Student’s t-test (P<0.05.Results: Patients treated with rotary instruments experienced significantly less post-endodontic pain than those treated with hand instruments (P<0.001.Conclusion: The use of Mtwo (NiTi rotary instruments in root canal preparation contributed to lower incidence of postoperative pain than hand K-files.

  14. Renewal-anomalous-heterogeneous files

    International Nuclear Information System (INIS)

    Flomenbom, Ophir

    2010-01-01

    Renewal-anomalous-heterogeneous files are solved. A simple file is made of Brownian hard spheres that diffuse stochastically in an effective 1D channel. Generally, Brownian files are heterogeneous: the spheres' diffusion coefficients are distributed and the initial spheres' density is non-uniform. In renewal-anomalous files, the distribution of waiting times for individual jumps is not exponential as in Brownian files, yet obeys: ψ α (t)∼t -1-α , 0 2 >, obeys, 2 >∼ 2 > nrml α , where 2 > nrml is the MSD in the corresponding Brownian file. This scaling is an outcome of an exact relation (derived here) connecting probability density functions of Brownian files and renewal-anomalous files. It is also shown that non-renewal-anomalous files are slower than the corresponding renewal ones.

  15. PC Graphic file programing

    International Nuclear Information System (INIS)

    Yang, Jin Seok

    1993-04-01

    This book gives description of basic of graphic knowledge and understanding and realization of graphic file form. The first part deals with graphic with graphic data, store of graphic data and compress of data, programing language such as assembling, stack, compile and link of program and practice and debugging. The next part mentions graphic file form such as Mac paint file, GEM/IMG file, PCX file, GIF file, and TIFF file, consideration of hardware like mono screen driver and color screen driver in high speed, basic conception of dithering and conversion of formality.

  16. 49 CFR 512.6 - How should I prepare documents when submitting a claim for confidentiality?

    Science.gov (United States)

    2010-10-01

    ... file's associated program. When alternative markings are used, such as font changes or symbols, the submitter must use one method consistently for electronic files of the same type within the same submission...

  17. Experiences on File Systems: Which is the best file system for you?

    CERN Document Server

    Blomer, J

    2015-01-01

    The distributed file system landscape is scattered. Besides a plethora of research file systems, there is also a large number of production grade file systems with various strengths and weaknesses. The file system, as an abstraction of permanent storage, is appealing because it provides application portability and integration with legacy and third-party applications, including UNIX utilities. On the other hand, the general and simple file system interface makes it notoriously difficult for a distributed file system to perform well under a variety of different workloads. This contribution provides a taxonomy of commonly used distributed file systems and points out areas of research and development that are particularly important for high-energy physics.

  18. AAS Publishing News: Preparing Your Manuscript Just Got Easier

    Science.gov (United States)

    Kohler, Susanna

    2016-03-01

    Watermarking using the command watermark{DRAFT, v2}.Are you an astronomer considering submitting a paper to an AAS journal (i.e., AJ, ApJ, ApJ Letters, or ApJ Supplements)? If so, this post is for you! Read on to find out about the exciting new things you can do with the AASs newest LaTeX class file, available for download now.Why the Update?AAS publishing has maintained a consistent class file for LaTeX manuscript preparation for the past decade. But academic publishing is changing rapidly in todays era of electronic journals! Since its journals went fully electronic, the AAS has been continuously adding new publishing capabilities based on the recommendations of the Journals Task Force and the needs and requests of AAS authors. The AASs manuscript preparation tools are now being updated accordingly.Whats New in AASTex 6.0?There are many exciting new features and capabilities in AASTex 6.0. Here are just a few:Tracking options for author revisions include added{text}, deleted{text}, replaced{old}{new}, and explain{text}.Based on emulateapjDo you use the popular class file emulateapj to prepare your manuscripts? AASTex 6.0 is based on emulateapj, rather than on the older AASTex 5.2 (though 5.2 is still supported). This means that it is easy to produce a double-columned, single-spaced, and astro-ph-ready manuscript. Since two thirds of the AAS journals authors use emulateapj, this transition was designed to make manuscript preparation and sharing an easier and more seamless process.Tools for collaborationsDo you work in a large collaboration? AASTex now includes new tools to make preparing a manuscript within a collaboration easier. Drafts can now be watermarked to differentiate between versions. New markup for large author lists streamlines the display so that readers can access article information immediately, yet they can still access the full author list and affiliations at the end of the paper. And author revision markup allows members of a collaboration to

  19. New thermal neutron scattering files for ENDF/B-VI release 2

    International Nuclear Information System (INIS)

    MacFarlane, R.E.

    1994-03-01

    At thermal neutron energies, the binding of the scattering nucleus in a solid, liquid, or gas affects the cross section and the distribution of secondary neutrons. These effects are described in the thermal sub-library of Version VI of the Evaluated Nuclear Data Files (ENDF/B-VI) using the File 7 format. In the original release of the ENDF/B-VI library, the data in File 7 were obtained by converting the thermal scattering evaluations of ENDF/B-III to the ENDF-6 format. These original evaluations were prepared at General Atomics (GA) in the late sixties, and they suffer from accuracy limitations imposed by the computers of the day. This report describes new evaluations for six of the thermal moderator materials and six new cold moderator materials. The calculations were made with the LEAPR module of NJOY, which uses methods based on the British code LEAP, together with the original GA physics models, to obtain new ENDF files that are accurate over a wider range of energy and momentum transfer than the existing files. The new materials are H in H 2 O, Be metal, Be in BeO, C in graphite, H in ZrH, Zr in ZrH, liquid ortho-hydrogen, liquid para-hydrogen, liquid ortho-deuterium, liquid para-deuterium liquid methane, and solid methane

  20. Storing files in a parallel computing system using list-based index to identify replica files

    Science.gov (United States)

    Faibish, Sorin; Bent, John M.; Tzelnic, Percy; Zhang, Zhenhua; Grider, Gary

    2015-07-21

    Improved techniques are provided for storing files in a parallel computing system using a list-based index to identify file replicas. A file and at least one replica of the file are stored in one or more storage nodes of the parallel computing system. An index for the file comprises at least one list comprising a pointer to a storage location of the file and a storage location of the at least one replica of the file. The file comprises one or more of a complete file and one or more sub-files. The index may also comprise a checksum value for one or more of the file and the replica(s) of the file. The checksum value can be evaluated to validate the file and/or the file replica(s). A query can be processed using the list.

  1. Eight months of clinical experience with the Self-Adjusting File system.

    Science.gov (United States)

    Solomonov, Michael

    2011-06-01

    The Self-Adjusting File (SAF) system (ReDent-Nova, Ra'anana, Israel) has been recently introduced for the simultaneous instrumentation and irrigation of root canals. The SAF is claimed to adapt itself three dimensionally to the root canal, including its cross-section. It is operated with a continuous flow of sodium hypochlorite that is delivered into the root canal through the hollow file and claimed to be activated by sonic agitation of the irrigant. Our aim was to present for the first time clinical cases prepared with the SAF system and to describe a clinical classification of canals, according to their difficulty, with recommendations for endodontic treatment sequences for each category. This report is based on the experience of a single endodontist, who used the system to treat more than 50 consecutive primary endodontic cases over the prior 8 months. A clinical classification was developed which enabled the operator to select a treatment protocol for easy and optimal glide path preparation to be effectively used with the SAF file in the various root canals encountered in the clinical environment. Clinical classification of canal difficulty makes root canal treatment sequences with the SAF simple and predictable. Many types of cases can be treated with the SAF system although a novice user is advised to advance slowly along the learning curve from simpler to more complicated canals. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  2. Creating Customized Data Files in {E}-{P}rime: {A} Practical Tutorial

    Directory of Open Access Journals (Sweden)

    İyilikci, Osman

    2018-02-01

    Full Text Available There are packages that simplify experiment generation by taking advantage of graphical user interface. Typically, such packages create output files that are not in an appropriate format to be directly analyzed with a statistical package. For this reason, researchers must complete several time consuming steps, and use additional software to prepare data for a statistical analysis. The present paper suggests a particular E-Basic technique which is time saving in data analysis process and applicable to a wide range of experiments that measure reaction time and response accuracy. The technique demonstrated here makes it possible to create a customized and ready-to-analyze data file automatically while running an experiment designed in E-Prime environment.

  3. Influence of operator's experience on root canal shaping ability with a rotary nickel-titanium single-file reciprocating motion system.

    Science.gov (United States)

    Muñoz, Estefanía; Forner, Leopoldo; Llena, Carmen

    2014-04-01

    The aim of this study was to evaluate the influence of the operator's experience on the shaping of double-curvature simulated root canals with a nickel-titanium single-file reciprocating motion system. Sixty double-curvature root canals simulated in methacrylate blocks were prepared by 10 students without any experience in endodontics and by 10 professionals who had studied endodontics at the postgraduate level. The Reciproc-VDW system's R25 file was used in the root canal preparation. The blocks were photographed before and after the instrumentation, and the time of instrumentation was also evaluated. Changes in root canal dimensions were analyzed in 6 positions. Significant differences (P file reciprocating motion system Reciproc is not seen to be influenced by the operator's experience regarding the increase of the canal area. Previous training and the need to acquire experience are important in the use of this system, in spite of its apparent simplicity. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  4. 76 FR 44633 - Self-Regulatory Organizations; Chicago Board Options Exchange, Incorporated; Notice of Filing and...

    Science.gov (United States)

    2011-07-26

    ... opportunity to manipulate this product and disrupt the underlying market that a lower position limit may... the date on which it was filed, or such shorter time as the Commission may designate, if consistent... five business days prior to the date of filing of the proposed rule change or such shorter time as...

  5. PCF File Format.

    Energy Technology Data Exchange (ETDEWEB)

    Thoreson, Gregory G [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-08-01

    PCF files are binary files designed to contain gamma spectra and neutron count rates from radiation sensors. It is the native format for the GAmma Detector Response and Analysis Software (GADRAS) package [1]. It can contain multiple spectra and information about each spectrum such as energy calibration. This document outlines the format of the file that would allow one to write a computer program to parse and write such files.

  6. The Comparative Efficacy of Different Files in The Removal of Different Sealers in Simulated Root Canal Retreatment- An In-vitro Study.

    Science.gov (United States)

    Kanaparthy, Aruna; Kanaparthy, Rosaiah

    2016-05-01

    Root canal treatment enjoys a high success rate all over the world and has saved billions of teeth from extraction. However, there are instances of failure, the main causes being insufficient cleaning and inadequate obturation. In such cases the most conservative treatment option would be non-surgical retreatment. It requires regaining access to the entire root canal system through removal of the original root canal filling thus permitting further cleaning and re- obturation. Removal of gutta-percha and sealer becomes a critical step to gain access to the root canal system, remove necrotic tissue debris, bacteria and infected dentin. To compare and evaluate the efficacy of manual hand Hedstrom files and two rotary retreatment file systems ProTaper Universal retreatment files and Mtwo(R) (retreatment) files in the removal of root canal filling material during root canal retreatment and the influence of the type of sealers zinc oxide eugenol and AH plus on the presence of remaining debris in the reinstrumented canals in the apical, middle and coronal third. Sixty single rooted human premolar teeth were divided into 3 Groups of 20 teeth each Group I (20 Teeth): prepared using hand K Files, Group II (20 Teeth): prepared using ProTaper rotary system and Group III (20 Teeth): prepared using Mtwo rotary system. In Groups- IA, IIA, IIIA: (10 teeth each) Obturation was done using Zinc Oxide Eugenol sealer and gutta percha. In Groups- IB, IIB, IIIB: (10 teeth each) obturation was done with AH Plus sealer and gutta percha. All the teeth were subjected to retreatment. Groups IA and IB with Hedstrom files, Groups IIA and IIB with ProTaper retreatment files and for Groups IIIA and IIIB with Mtwo retreatment Files. The roots were longitudinally split and were observed under a stereomicroscope for remaining amount of filling material on the canal walls. Statistical analysis was done using One-way ANOVA (Analysis of variance) test and Tukey HSD Test. Mtwo(R) files showed

  7. Analysis of mechanical preparations in extracted teeth using ProTaper rotary instruments: value of the safety quotient.

    Science.gov (United States)

    Blum, J Y; Machtou, P; Ruddle, C; Micallef, J P

    2003-09-01

    The purpose of this study was to apply the Endographe to analyze the vertical forces and torque developed during mechanical preparations in extracted teeth. The data collected in this study may be used to calculate the safety quotient (SQ) as proposed by J.T. McSpadden. The SQ formula is defined as the torque required to break a file at D3 divided by the mean working torque required to cut dentin. The Endographe is a unique force-analyzer device equipped to measure, record, and generate graphs of the vertical forces and torque exerted during root canal preparation. All preparations were performed by endodontists in roots with narrow, more restrictive canals, larger, more open canals, or in roots sectioned in two halves. All canals, including the sectioned canals, were prepared with ProTaper files in accordance with the manufacturer's guidelines for use. For narrow canals, the mean values of the generated vertical forces (g) and torque (g.cm) varied from 80 (+/- 20) g (SX) to 232 (+/- 60) g (F2) and from 80 (+/- 24) g x cm (F1) to 150 (+/- 45) g x cm (S2), respectively. For large canals, the mean values of the generated vertical forces (g) and torque (g x cm) varied from 80 (+/- 20) g (SX) to 340 (+/- 20) g (F1) and from 31 (+/- 9) g x cm (S2) to 96 (+/- 35) g x cm (SX), respectively. The SQ varied from 0.93 to 7.95 for narrow canals and from 1.58 to 14.50 for large canals. The SQ is intended to provide values that can be analyzed to predict whether a rotary file will have a tendency to break or will work safely during clinical use. However, if the formula is going to provide useful information, it must index the "rotation to failure torque" with the "mean working torque" at a specific location along the cutting blades of a file. Additionally, this mathematical formula does not account for factors such as the concentration of forces, the way the instruments are used, or the wear of the instruments. A precise protocol for canal preparation should emphasize using

  8. Comparison of quality of obturation and instrumentation time using hand files and two rotary file systems in primary molars: A single-blinded randomized controlled trial.

    Science.gov (United States)

    Govindaraju, Lavanya; Jeevanandan, Ganesh; Subramanian, E M G

    2017-01-01

    In permanent dentition, different rotary systems are used for canal cleaning and shaping. Rotary instrumentation in pediatric dentistry is an emerging concept. A very few studies have compared the efficiency of rotary instrumentation for canal preparation in primary teeth. Hence, this study was performed to compare the obturation quality and instrumentation time of two rotary files systems - Protaper, Mtwo with hand files in primary molars. Forty-five primary mandibular molars were randomly allotted to one of the three groups. Instrumentation was done using K-files in Group 1; Protaper in Group 2; and Mtwo in Group 3. Instrumentation time was recorded. The canal filling quality was assessed as underfill, optimal fill, and overfill. Statistical analysis was done using Chi-square, ANOVA, and post hoc Tukey test. No significant difference was observed in the quality of obturation among three groups. Intergroup comparison of the instrumentation time showed a statistically significant difference between the three groups. The use of rotary instrumentation in primary teeth results in marked reduction in the instrumentation time and improves the quality of obturation.

  9. Formatting data files for repeated-measures analyses in SPSS: Using the Aggregate and Restructure procedures

    Directory of Open Access Journals (Sweden)

    Gyslain Giguère

    2006-03-01

    Full Text Available In this tutorial, we demonstrate how to use the Aggregate and Restructure procedures available in SPSS (versions 11 and up to prepare data files for repeated-measures analyses. In the first two sections of the tutorial, we briefly describe the Aggregate and Restructure procedures. In the final section, we present an example in which the data from a fictional lexical decision task are prepared for analysis using a mixed-design ANOVA. The tutorial demonstrates that the presented method is the most efficient way to prepare data for repeated-measures analyses in SPSS.

  10. Endodontic Treatment of Maxillary Premolar with Three Root Canals Using Optical Microscope and NiTi Rotatory Files System.

    Science.gov (United States)

    Relvas, João Bosco Formiga; de Carvalho, Fredsom Marcio Acris; Marques, André Augusto Franco; Sponchiado, Emílio Carlos; Garcia, Lucas da Fonseca Roberti

    2013-01-01

    The aim of the study was to report a clinical case of endodontic treatment of a maxillary first premolar with three root canals using an optical microscope and rotary instrumentation technique. The main complaint of the patient, a 16-year-old girl, was pain in tooth 14. After clinical and radiographic examination, irreversible pulpitis was diagnosed. An alteration in the middle third of the pulp chamber radiographically observed suggested the presence of three root canals. Pulp chamber access and initial catheterization using size number 10 K-files were performed. The optical microscope and radiographic examination were used to confirm the presence of three root canals. PathFiles #13, #16, and #19 were used to perform catheterization and ProTaper files S1 and S2 for cervical preparation. Apical preparation was performed using F1 file in the buccal canals and F2 in the palatal canal up to the working length. The root canals were filled with Endofill sealer by thermal compaction technique using McSpadden #50. The case has been receiving follow-up for 12 months and no painful symptomatology or periapical lesions have been found. The use of technological tools was able to assist the endodontic treatment of teeth with complex internal anatomy, such as three-canal premolars.

  11. Comparison of Curved Root Canals Prepared with Various Chelating Agents

    Science.gov (United States)

    2012-06-01

    aqueous base (11). According to Bramante and Betti, instrumentation with NiTi hand files using EDTA caused greater deviation of the root canal from...15. Peters OA, Peters CI, Schonenberger K, Barbakow F. ProTaper rotary root canal preparation: effects of canal anatomy on final shape analysed by

  12. Evaluated nuclear data file libraries use in nuclear-physical calculations

    International Nuclear Information System (INIS)

    Gritsaj, O.O.; Kalach, N.Yi.; Kal'chenko, O.Yi.; Kolotij, V.V.; Vlasov, M.F.

    1994-01-01

    The necessity of nuclear updated usage is founded for neutron experiment modeling calculations, for preparation of suitable data for reactor calculations and for other applications that account of detail energetic structure of cross section is required. The scheme of system to coordinate the work to collect and to prepare evaluated nuclear data on an international scale is presented. Main updated and recommended nuclear data libraries and associated computer programs are reviewed. Total neutron cross sections for 28 energetic groups calculated on the base of natural mixture iron isotopes evaluated nuclear data file (BROND-2, 1991) have been compared with BNAB-78 data. (author). 7 refs., 1 tab., 4 figs

  13. Text File Comparator

    Science.gov (United States)

    Kotler, R. S.

    1983-01-01

    File Comparator program IFCOMP, is text file comparator for IBM OS/VScompatable systems. IFCOMP accepts as input two text files and produces listing of differences in pseudo-update form. IFCOMP is very useful in monitoring changes made to software at the source code level.

  14. An in vitro study: Evaluation of intracanal calcium hydroxide removal with different file systems

    Directory of Open Access Journals (Sweden)

    Atul Jain

    2017-01-01

    Full Text Available Background: Calcium hydroxide (Ca(OH2 is the most commonly used intracanal material; it needs to be removed in entirety before obturation. Several techniques have been used for the same including use of various hand and rotary files. Aim: This study was carried out to compare the efficacy of Hand K files and single and multiple rotary file system in removal of Ca(OH2. Methodology: Distobuccal root of 45 maxillary molars were selected on the basis of specified inclusion and exclusion criteria. They were divided into three groups - Group 1 (H and K file, Group 2 (HERO Shaper, and Group 3 (One Shape. Biomechanical preparation (BMP was carried out as per the manufacturer's instructions; 2.5% sodium hypochlorite was used as the irrigant and 17% ethylenediaminetetraacetic acid as the penultimate irrigant. Ca(OH2powder was mixed with normal saline to obtain a paste; canals were filled with this paste using a Lentulo spiral and were sealed. After 7 days, Ca(OH2was removed, using the same file system as that used for BMP. Samples were sectioned longitudinally and evaluated under a stereomicroscope. Statistical Analysis: Statistical analysis of the obtained data was carried out using one-way analysis of variance test. Results: HERO Shaper displayed better removal of Ca(OH2than One Shape and Hand K file. Moreover, removal was better in the middle third of canal than apical third. Conclusion: Multiple rotary file system (HERO Shaper is more effective in removal of Ca(OH2than the single file system (One Shape

  15. Quantitative evaluation of apically extruded debris with different single-file systems: Reciproc, F360 and OneShape versus Mtwo.

    Science.gov (United States)

    Bürklein, S; Benten, S; Schäfer, E

    2014-05-01

    To assess in a laboratory setting the amount of apically extruded debris associated with different single-file nickel-titanium instrumentation systems compared to one multiple-file rotary system. Eighty human mandibular central incisors were randomly assigned to four groups (n = 20 teeth per group). The root canals were instrumented according to the manufacturers' instructions using the reciprocating single-file system Reciproc, the single-file rotary systems F360 and OneShape and the multiple-file rotary Mtwo instruments. The apically extruded debris was collected and dried in pre-weighed glass vials. The amount of debris was assessed with a micro balance and statistically analysed using anova and post hoc Student-Newman-Keuls test. The time required to prepare the canals with the different instruments was also recorded. Reciproc produced significantly more debris compared to all other systems (P file rotary systems and the multiple-file rotary system (P > 0.05). Instrumentation with the three single-file systems was significantly faster than with Mtwo (P systems caused apical debris extrusion. Rotary instrumentation was associated with less debris extrusion compared to reciprocal instrumentation. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  16. Energy consumption of ProTaper Next X1 after glide path with PathFiles and ProGlider.

    Science.gov (United States)

    Berutti, Elio; Alovisi, Mario; Pastorelli, Michele Angelo; Chiandussi, Giorgio; Scotti, Nicola; Pasqualini, Damiano

    2014-12-01

    Instrument failure caused by excessive torsional stress can be controlled by creating a manual or mechanical glide path. The ProGlider single-file system (Dentsply Maillefer, Ballaigues, Switzerland) was recently introduced to perform a mechanical glide path. This study was designed to compare the effect of a glide path performed with PathFiles (Dentsply Maillefer) and ProGlider on torque, time, and pecking motion required for ProTaper Next X1 (Dentsply Maillefer) to reach the full working length in simulated root canals. Forty Endo Training Blocks (Dentsply Maillefer) were used. Twenty were prepared with a mechanical glide path using PathFiles 1 and 2 (the PathFile group), and 20 were prepared with a mechanical glide path using a ProGlider single file (the ProGlider group). All samples were shaped with ProTaper Next X1 driven by an endodontic motor connected to a digital wattmeter. The required torque for root canal instrumentation was analyzed by evaluating the electrical power consumption of the endodontic engine. Electric power consumption (mW/h), elapsed time (seconds), and number of pecking motions required to reach the full working length with ProTaper Next X1 were calculated. Differences among groups were analyzed with the parametric Student t test for independent data (P < .05). Elapsed time and electric power consumption were significantly different between groups (P = .0001 for both). ProGlider appears to perform more efficiently than PathFiles in decreasing electric power consumption of ProTaper Next X1 to reach the full working length. This study confirmed the ability of ProGlider to reduce stress in ProTaper Next X1 during shaping through a glide path and preliminary middle and coronal preflaring. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  17. Incidence of apical crack initiation and propagation during the removal of root canal filling material with ProTaper and Mtwo rotary nickel-titanium retreatment instruments and hand files.

    Science.gov (United States)

    Topçuoğlu, Hüseyin Sinan; Düzgün, Salih; Kesim, Bertan; Tuncay, Oznur

    2014-07-01

    The aim of this study was to determine the incidence of crack initiation and propagation in apical root dentin after retreatment procedures performed by using 2 rotary retreatment systems and hand files with additional instrumentation. Eighty extracted mandibular premolars with single canals were selected. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the control group, and no preparation was performed. The remaining 60 teeth were prepared to size 35 with rotary files and filled with gutta-percha and AH Plus sealer. Specimens were then divided into 3 groups (n = 20), and retreatment procedures were performed with the following devices and techniques: ProTaper Universal retreatment files, Mtwo retreatment files, and hand files. After retreatment, the additional instrumentation was performed by using size 40 ProTaper, Mtwo, and hand files. Digital images of the apical root surface were recorded before preparation, after instrumentation, after filling, after retreatment, and after additional instrumentation. The images were then inspected for the presence of any new apical cracks and propagation. Data were analyzed with the logistic regression and Fisher exact tests. All experimental groups caused crack initiation and propagation after use of retreatment instruments. The ProTaper and Mtwo retreatment groups caused greater crack initiation and propagation than the hand instrument group (P ProTaper and Mtwo instruments after the use of retreatment instruments caused crack initiation and propagation, whereas hand files caused neither crack initiation nor propagation (P < .05). This study showed that retreatment procedures and additional instrumentation after the use of retreatment files may cause crack initiation and propagation in apical dentin. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  18. COMBINE archive and OMEX format: one file to share all information to reproduce a modeling project.

    Science.gov (United States)

    Bergmann, Frank T; Adams, Richard; Moodie, Stuart; Cooper, Jonathan; Glont, Mihai; Golebiewski, Martin; Hucka, Michael; Laibe, Camille; Miller, Andrew K; Nickerson, David P; Olivier, Brett G; Rodriguez, Nicolas; Sauro, Herbert M; Scharm, Martin; Soiland-Reyes, Stian; Waltemath, Dagmar; Yvon, Florent; Le Novère, Nicolas

    2014-12-14

    With the ever increasing use of computational models in the biosciences, the need to share models and reproduce the results of published studies efficiently and easily is becoming more important. To this end, various standards have been proposed that can be used to describe models, simulations, data or other essential information in a consistent fashion. These constitute various separate components required to reproduce a given published scientific result. We describe the Open Modeling EXchange format (OMEX). Together with the use of other standard formats from the Computational Modeling in Biology Network (COMBINE), OMEX is the basis of the COMBINE Archive, a single file that supports the exchange of all the information necessary for a modeling and simulation experiment in biology. An OMEX file is a ZIP container that includes a manifest file, listing the content of the archive, an optional metadata file adding information about the archive and its content, and the files describing the model. The content of a COMBINE Archive consists of files encoded in COMBINE standards whenever possible, but may include additional files defined by an Internet Media Type. Several tools that support the COMBINE Archive are available, either as independent libraries or embedded in modeling software. The COMBINE Archive facilitates the reproduction of modeling and simulation experiments in biology by embedding all the relevant information in one file. Having all the information stored and exchanged at once also helps in building activity logs and audit trails. We anticipate that the COMBINE Archive will become a significant help for modellers, as the domain moves to larger, more complex experiments such as multi-scale models of organs, digital organisms, and bioengineering.

  19. Inter-comparison of High Energy Files (neutron-induced, from 20 to 150 MeV)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young-Ouk; Fukahori, Tokio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-11-01

    Recent new applications using accelerator-driven system require well-tested nuclear data when modeling the interaction of neutrons above 20 MeV. This work is aimed to review evaluation methods applied in currently available neutron high energy files above 20 to 150 MeV, to inter-compare their evaluated cross sections on some important isotopes, and to analyze resulting discrepancies. Through out these, integrities and consistencies of the high energy files are checked, applicability of physics models and evaluation methodologies are assessed, and some directions are derived to improve and expand current JENDL High Energy File. (author)

  20. 75 FR 45106 - Great River Hydropower, LLC; Notice of Application Tendered for Filing With the Commission and...

    Science.gov (United States)

    2010-08-02

    ... Hydropower, LLC; Notice of Application Tendered for Filing With the Commission and Soliciting Additional... License. b. Project No.: P-13637-001. c. Date filed: July 12, 2010. d. Applicant: Great River Hydropower.... 21, and would consist of the following facilities: (1) A new hydropower structure, located about 100...

  1. An in vitro comparison of root canal transportation by reciproc file with and without glide path.

    Science.gov (United States)

    Nazarimoghadam, Kiumars; Daryaeian, Mohammad; Ramazani, Nahid

    2014-09-01

    The aim of ideal canal preparation is to prevent iatrogenic aberrations such as transportation. The aim of this study was to evaluate the root canal transportation by Reciproc file with and without glide path. Thirty acrylic-resin blocks with a curvature of 60° and size#10 (2% taper) were assigned into two groups (n= 15). In group 1, the glide path was performed using stainless steel k-files size#10 and 15 at working length In group 2, canals were prepared with Reciproc file system at working length. By using digital imaging software (AutoCAD 2008), the pre-instrumentation and post-instrumentation digital images were superimposed over, taking the landmarks as reference points. Then the radius of the internal and external curve of the specimens was calculated at three α, β and γ points (1mm to apex as α, 3mm to apex as β, and 5mm to apex as γ). The data were statically analyzed using the independent T-test and Mann-Whitney U test by SPSS version 16. Glide path was found significant for only external curve in the apical third of the canal; that is, 5mm to apex (P=0.005). But in the other third, canal modification was not significant (P> 0.008). Canal transportation in the apical third of the canal seems to be significantly reduced when glide path is performed using reciprocating files.

  2. Parcels and Land Ownership, This data set consists of digital map files containing parcel-level cadastral information obtained from property descriptions. Cadastral features contained in the data set include real property boundary lines, rights-of-way boundaries, property dimensions, Published in Not Provided, 1:2400 (1in=200ft) scale, Racine County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Parcels and Land Ownership dataset current as of unknown. This data set consists of digital map files containing parcel-level cadastral information obtained from...

  3. Structure, properties and wear behaviour of multilayer coatings consisting of metallic and covalent hard materials, prepared by magnetron sputtering

    International Nuclear Information System (INIS)

    Schier, V.

    1995-12-01

    Novel multilayer coatings with metallic and covalent layer materials were prepared by magnetron sputtering and characterised concerning structure, properties and application behaviour. At first single layer coatings were deposited for the determination of the material properties. To evaluate relations between structure and properties of the multilayer coatings, different multilayer concepts were realised: - coatings consisting of at most 7 layers of metallic hard materials, - 100-layer coatings consisting of metallic and covalent hard materials, - TiN-TiC multilayer coatings with different numbers of layers (between 10 and 1000), - 150-layer coatings, based on TiN-TiC multilayers, with thin ( 4 C, AlN, SiC, a:C, Si 3 N 4 , SiAlON). X-rays and electron microscopic analysis indicate in spite of nonstoichiometric compositions single phase crystalline structures for nonreactively and reactively sputtered metastable single layer Ti(B,C)-, Ti(B,N)- and Ti(B,C,N)-coatings. These single layer coatings show excellent mechanical properties (e.g. hardness values up to 6000 HV0,05), caused by lattice stresses as well as by atomic bonding conditions similar to those in c:BN and B 4 C. The good tribological properties shown in pin-on-disk-tests can be attributed to the very high hardness of the coatings. The coatings consisting of at most 7 layers of metallic hard materials show good results mainly for the cutting of steel Ck45, due to the improved mechanical properties (e.g. hardness, toughness) of the multilayers compared to the single layer coatings. This improvement is caused by inserting the hard layer materials and the coherent reinforcement of the coatings. (orig.)

  4. 76 FR 2359 - Great River Hydropower, LLC; Notice of Application Accepted for Filing and Soliciting Motions To...

    Science.gov (United States)

    2011-01-13

    ... Hydropower, LLC; Notice of Application Accepted for Filing and Soliciting Motions To Intervene and Protests... No.: P-13637-001. c. Date filed: July 12, 2010. d. Applicant: Great River Hydropower, LLC. e. Name of...: (1) A new 796-foot-long by 46-foot-wide by 25-foot-high concrete hydropower structure consisting of...

  5. Comparison of the amount of apical debris extrusion associated with different retreatment systems and supplementary file application during retreatment process.

    Science.gov (United States)

    Çiçek, Ersan; Koçak, Mustafa Murat; Koçak, Sibel; Sağlam, Baran Can

    2016-01-01

    The type of instrument affects the amount of debris extruded. The aim of this study was to compare the effect of retreatment systems and supplementary file application on the amount of apical debris extrusion. Forty-eight extracted mandibular premolars with a single canal and similar length were selected. The root canals were prepared with the ProTaper Universal system with a torque-controlled engine. The root canals were dried and were obturated using Gutta-percha and sealer. The specimens were randomly divided into four equal groups according to the retreatment procedures (Group 1, Mtwo retreatment files; Group 2, Mtwo retreatment files + Mtwo rotary file #30 supplementary file; Group 3, ProTaper Universal retreatment (PTUR) files; and Group 4, PTUR files + ProTaper F3 supplementary file). The extruded debris during instrumentation were collected into preweighed Eppendorf tubes. The amount of apically extruded debris was calculated by subtracting the initial weight of the tube from the final weight. Three consecutive weights were obtained for each tube. No statistically significant difference was found in the amount of apically extruded debris between Groups 1 and 3 (P = 0.590). A significant difference was observed between Groups 1 and 2 (P file significantly increased the amount of apically extruded debris.

  6. HUD GIS Boundary Files

    Data.gov (United States)

    Department of Housing and Urban Development — The HUD GIS Boundary Files are intended to supplement boundary files available from the U.S. Census Bureau. The files are for community planners interested in...

  7. A free software package for a human online conditioned suppression preparation

    NARCIS (Netherlands)

    Franssen, M.; Clarysse, J.; Beckers, T.; van Vooren, P.R.; Baeyens, F.

    2010-01-01

    Martians V2 is both a language syntax in which experiments can be written and an implementation of this syntax in a runtime application that, when fed a valid experiment text file, will execute the given experiment. It is based on the original Martians preparation, which has proven a valuable tool

  8. 75 FR 18200 - Enterprise Texas Pipeline LLC; Notice of Compliance Filing

    Science.gov (United States)

    2010-04-09

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR07-12-005] Enterprise..., Enterprise Texas Pipeline LLC (Enterprise Texas), filed its Statement of Operating Conditions in compliance... Commission's regulations. Enterprise Texas states that the revisions include modifications consistent with...

  9. 75 FR 18496 - Enterprise Texas Pipeline LLC; Notice of Compliance Filing

    Science.gov (United States)

    2010-04-12

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR07-12-005] Enterprise..., Enterprise Texas Pipeline LLC (Enterprise Texas), filed its Statement of Operating Conditions in compliance... Commission's regulations. Enterprise Texas states that the revisions include modifications consistent with...

  10. 33 CFR 148.246 - When is a document considered filed and where should I file it?

    Science.gov (United States)

    2010-07-01

    ... filed and where should I file it? 148.246 Section 148.246 Navigation and Navigable Waters COAST GUARD... Formal Hearings § 148.246 When is a document considered filed and where should I file it? (a) If a document to be filed is submitted by mail, it is considered filed on the date it is postmarked. If a...

  11. Report on the achievements in the Sunshine Project in fiscal 1986. Surveys on coal type selection and surveys on coal types (Data file); 1986 nendo tanshu sentei chosa tanshu chosa seika hokokusho. Data file

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1987-03-01

    This data file is a data file concerning coal types for liquefaction in the report on the achievements in the surveys on coal type selection and on coal types (JN0040843). Such items of information were filed as existence and production of coals, various kinds of analyses, and test values relative to data for liquefaction tests that have been collected and sent to date. The file consists of two files of a test sample information file related to existence and production of coals and coal mines, and an analysis and test file accommodating the results of different analyses and tests. However, the test sample information files (1) through (6) have not been put into order on such items of information as test samples and sample collection, geography, geology, ground beds, coal beds, coal mines, development and transportation. The analysis and test file contains (7) industrial analyses, (8) element analysis, (9) ash composition, (10) solubility of ash, (11) structure analysis, (12) liquefaction characteristics (standard version), (13) analysis of liquefaction produced gas, (14) distillation characteristics of liquefaction produced oil, (15) liquefaction characteristics (simplified version), (16) analysis of liquefaction produced gas (simplified version), and (17) distillation characteristics of liquefaction produced oil (simplified version). However, the information related to liquefaction test using a tubing reactor in (15) through (17) has not been put into order. (NEDO)

  12. Embedded system file transfer USB

    International Nuclear Information System (INIS)

    Jaoua, Mehdi

    2008-01-01

    The development of the communication series A emphasized new aspects of data exchange. The transfer of data, subject of my project of end of studies, consists in transferring from the files of a support of mass towards another via port USB. In first phase, I had like stain the realization of an embarked system allowing the communication between a key USB and final of communication such as a Pc. For this fact, I had to include/understand the operation of protocol USB and thus I could programmed a Peak to manage this communication. The second phase, will consist in extending this project towards a transmission de< donnees between two keys USB without intervention of a powerful machine equipped with an operating system pour rant to manage this transaction. (Author)

  13. Protecting your files on the DFS file system

    CERN Multimedia

    Computer Security Team

    2011-01-01

    The Windows Distributed File System (DFS) hosts user directories for all NICE users plus many more data.    Files can be accessed from anywhere, via a dedicated web portal (http://cern.ch/dfs). Due to the ease of access to DFS with in CERN it is of utmost importance to properly protect access to sensitive data. As the use of DFS access control mechanisms is not obvious to all users, passwords, certificates or sensitive files might get exposed. At least this happened in past to the Andrews File System (AFS) - the Linux equivalent to DFS) - and led to bad publicity due to a journalist accessing supposedly "private" AFS folders (SonntagsZeitung 2009/11/08). This problem does not only affect the individual user but also has a bad impact on CERN's reputation when it comes to IT security. Therefore, all departments and LHC experiments agreed recently to apply more stringent protections to all DFS user folders. The goal of this data protection policy is to assist users in pro...

  14. Protecting your files on the AFS file system

    CERN Multimedia

    2011-01-01

    The Andrew File System is a world-wide distributed file system linking hundreds of universities and organizations, including CERN. Files can be accessed from anywhere, via dedicated AFS client programs or via web interfaces that export the file contents on the web. Due to the ease of access to AFS it is of utmost importance to properly protect access to sensitive data in AFS. As the use of AFS access control mechanisms is not obvious to all users, passwords, private SSH keys or certificates have been exposed in the past. In one specific instance, this also led to bad publicity due to a journalist accessing supposedly "private" AFS folders (SonntagsZeitung 2009/11/08). This problem does not only affect the individual user but also has a bad impact on CERN's reputation when it comes to IT security. Therefore, all departments and LHC experiments agreed in April 2010 to apply more stringent folder protections to all AFS user folders. The goal of this data protection policy is to assist users in...

  15. Zebra: A striped network file system

    Science.gov (United States)

    Hartman, John H.; Ousterhout, John K.

    1992-01-01

    The design of Zebra, a striped network file system, is presented. Zebra applies ideas from log-structured file system (LFS) and RAID research to network file systems, resulting in a network file system that has scalable performance, uses its servers efficiently even when its applications are using small files, and provides high availability. Zebra stripes file data across multiple servers, so that the file transfer rate is not limited by the performance of a single server. High availability is achieved by maintaining parity information for the file system. If a server fails its contents can be reconstructed using the contents of the remaining servers and the parity information. Zebra differs from existing striped file systems in the way it stripes file data: Zebra does not stripe on a per-file basis; instead it stripes the stream of bytes written by each client. Clients write to the servers in units called stripe fragments, which are analogous to segments in an LFS. Stripe fragments contain file blocks that were written recently, without regard to which file they belong. This method of striping has numerous advantages over per-file striping, including increased server efficiency, efficient parity computation, and elimination of parity update.

  16. Preparation of CuIn{sub 1-x}Ga{sub x}S{sub 2} (x = 0.5) flowers consisting of nanoflakes via a solvothermal method

    Energy Technology Data Exchange (ETDEWEB)

    Liang Xiaojuan [College of Chemistry and Materials Engineering, Wenzhou University, Wenzhou, Zhejiang Province 325035 (China); Institute of Materials and Technology, Dalian Maritime University, Dalian 116026 (China); Zhong Jiasong; Yang Fan; Hua Wei; Jin Huaidong [College of Chemistry and Materials Engineering, Wenzhou University, Wenzhou, Zhejiang Province 325035 (China); Liu Haitao, E-mail: lht@wzu.edu.cn [College of Chemistry and Materials Engineering, Wenzhou University, Wenzhou, Zhejiang Province 325035 (China); Sun Juncai [Institute of Materials and Technology, Dalian Maritime University, Dalian 116026 (China); Xiang Weidong, E-mail: weidongxiang@yahoo.com.cn [College of Chemistry and Materials Engineering, Wenzhou University, Wenzhou, Zhejiang Province 325035 (China)

    2011-05-26

    Highlights: > We report for the first time a small biomolecule-assisted route using L-cysteine as sulfur source and complexing agent to synthesis CuIn{sub 0.5}Ga{sub 0.5}S{sub 2} crystals. > The possible mechanisms leading to CuIn{sub 0.5}Ga{sub 0.5}S{sub 2} flowers consisting of nanoflakes were proposed. > In addition, the morphology, structure, and phase composition of the as-prepared CuIn{sub 0.5}Ga{sub 0.5}S{sub 2} products were investigated in detail by XRD, FESEM, EDS, XPS, TEM (HRTEM) and SAED. - Abstract: CuIn{sub 1-x}Ga{sub x}S{sub 2} (x = 0.5) flowers consisting of nanoflakes were successfully prepared by a biomolecule-assisted solvothermal route at 220 deg. C for 10 h, employing copper chloride, gallium chloride, indium chloride and L-cysteine as precursors. The biomolecule L-cysteine acting as sulfur source was found to play a very important role in the formation of the final product. The diameter of the CuIn{sub 0.5}Ga{sub 0.5}S{sub 2} flowers was 1-2 {mu}m, and the thickness of the flakes was about 15 nm. The obtained products were characterized by X-ray diffraction (XRD), energy dispersion spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), field-emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), high-resolution transmission electron microscopy (HRTEM), selected area electron diffraction spectroscopy (SAED), and UV-vis absorption spectroscopy. The influences of the reaction temperature, reaction time, sulfur source and the molar ratio of Cu-to-L-cysteine (reactants) on the formation of the target compound were investigated. The formation mechanism of the CuIn{sub 0.5}Ga{sub 0.5}S{sub 2} flowers consisting of flakes was discussed.

  17. Download this PDF file

    African Journals Online (AJOL)

    Education

    sugar and affordable clothes. This is ... also by preparing a rich diet from ingredients acquired with ... This is another government programme consisting of mixing soil ..... Sciences and Humanities Research Council of Canada (SSHRC).

  18. Evaluation of Single File Systems Reciproc, Oneshape, and WaveOne using Cone Beam Computed Tomography -An In Vitro Study.

    Science.gov (United States)

    Dhingra, Annil; Ruhal, Nidhi; Miglani, Anjali

    2015-04-01

    Successful endodontic therapy depends on many factor, one of the most important step in any root canal treatment is root canal preparation. In addition, respecting the original shape of the canal is of the same importance; otherwise, canal aberrations such as transportation will be created. The purpose of this study is to compare and evaluate Reciprocating WaveOne ,Reciproc and Rotary Oneshape Single File Instrumentation System On Cervical Dentin Thickness, Cross Sectional Area and Canal Transportation on First Mandibular Molar Using Cone Beam Computed Tomography. Sixty Mandibular First Molars extracted due to periodontal reason was collected from the Department of Oral and Maxillofacial. Teeth were prepared using one rotary and two reciprocating single file system. Teeth were divided into 3 groups 20 teeth in each group. Pre instrumentation and Post instrumentation scans was done and evaluated for three parameters Canal Transportation, Cervical Dentinal Thickness, Cross-sectional Area. Results were analysed statistically using ANOVA, Post-Hoc Tukey analysis. The change in cross-sectional area after filing showed significant difference at 0mm, 1mm, 2mm and 7mm (pfile system over a distance of 7 mm (starting from 0mm and then evaluation at 1mm, 2mm, 3mm, 5mm and 7mm), the results showed a significant difference among the file systems at various lengths (p= 0.014, 0.046, 0.004, 0.028, 0.005 & 0.029 respectively). Mean value of cervical dentinal removal is maximum at all the levels for oneshape and minimum for waveone showing the better quality of waveone and reciproc over oneshape file system. Significant difference was found at 9mm, 11mm and 12mm between all the three file systems (p<0.001,< 0.001, <0.001). It was concluded that reciprocating motion is better than rotary motion in all the three parameters Canal Transportation, Cross-sectional Area, Cervical Dentinal Thickness.

  19. JENDL Dosimetry File

    International Nuclear Information System (INIS)

    Nakazawa, Masaharu; Iguchi, Tetsuo; Kobayashi, Katsuhei; Iwasaki, Shin; Sakurai, Kiyoshi; Ikeda, Yujiro; Nakagawa, Tsuneo.

    1992-03-01

    The JENDL Dosimetry File based on JENDL-3 was compiled and integral tests of cross section data were performed by the Dosimetry Integral Test Working Group of the Japanese Nuclear Data Committee. Data stored in the JENDL Dosimetry File are the cross sections and their covariance data for 61 reactions. The cross sections were mainly taken from JENDL-3 and the covariances from IRDF-85. For some reactions, data were adopted from other evaluated data files. The data are given in the neutron energy region below 20 MeV in both of point-wise and group-wise files in the ENDF-5 format. In order to confirm reliability of the data, several integral tests were carried out; comparison with the data in IRDF-85 and average cross sections measured in fission neutron fields, fast reactor spectra, DT neutron fields and Li(d, n) neutron fields. As a result, it has been found that the JENDL Dosimetry File gives better results than IRDF-85 but there are some problems to be improved in future. The contents of the JENDL Dosimetry File and the results of the integral tests are described in this report. All of the dosimetry cross sections are shown in a graphical form. (author) 76 refs

  20. JENDL Dosimetry File

    Energy Technology Data Exchange (ETDEWEB)

    Nakazawa, Masaharu; Iguchi, Tetsuo [Tokyo Univ. (Japan). Faculty of Engineering; Kobayashi, Katsuhei [Kyoto Univ., Kumatori, Osaka (Japan). Research Reactor Inst.; Iwasaki, Shin [Tohoku Univ., Sendai (Japan). Faculty of Engineering; Sakurai, Kiyoshi; Ikeda, Yujior; Nakagawa, Tsuneo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1992-03-15

    The JENDL Dosimetry File based on JENDL-3 was compiled and integral tests of cross section data were performed by the Dosimetry Integral Test Working Group of the Japanese Nuclear Data Committee. Data stored in the JENDL Dosimetry File are the cross sections and their covariance data for 61 reactions. The cross sections were mainly taken from JENDL-3 and the covariances from IRDF-85. For some reactions, data were adopted from other evaluated data files. The data are given in the neutron energy region below 20 MeV in both of point-wise and group-wise files in the ENDF-5 format. In order to confirm reliability of the data, several integral tests were carried out; comparison with the data in IRDF-85 and average cross sections measured in fission neutron fields, fast reactor spectra, DT neutron fields and Li(d,n) neutron fields. As a result, it has been found that the JENDL Dosimetry File gives better results than IRDF-85 but there are some problems to be improved in future. The contents of the JENDL Dosimetry File and the results of the integral tests are described in this report. All of the dosimetry cross sections are shown in a graphical form.

  1. "Dentinal microcracks after root canal preparation" a comparative evaluation with hand, rotary and reciprocating instrumentation.

    Science.gov (United States)

    Priya, N Tulasi; Chandrasekhar, Veeramachaneni; Anita, S; Tummala, Muralidhar; Raj, T B Phanindhar; Badami, Vijetha; Kumar, Pradeep; Soujanya, E

    2014-12-01

    The purpose of this study was to compare the incidence of dentinal micro cracks after instrumentation with various types of NiTi files in rotary and reciprocating motion. One hundred human extracted mandibular central incisors were taken and divided into 10 groups (n=10 teeth per group). Group 1- No preparation, Group 2 - Hand instrumentation, Groups 3,4 - ProTaper files in rotary and reciprocating motion, Groups 5,6 - ProTaper Next files in rotary and reciprocating motion, Groups 7,8 - Oneshape files in rotary and reciprocating motion, Groups 9,10 - Reciproc files in rotary and reciprocating motion. Specimens were sectioned horizontally at 3,6 and 9 mm from the apex and dentinal micro cracks were observed under a stereomicroscope. There was a statistically significant difference between the groups (pProtaper Next - Rot, Protaper Next - Rec, Reciproc - Rec); (ProTaper - Rot, ProTaper - Rec, Oneshape - Rot), (Oneshape - Rot, Reciproc - Rot), (One shape Reciproc, Reciproc - Rec); (p >.05). Least cracks were seen in canals instrumented with Pro Taper Next files both in rotary and reciprocating motion. Full sequence rotary systems showed less cracks than single file systems and full sequence rotary systems showed less cracks in reciprocating motion than in rotary motion.

  2. 75 FR 18556 - Self-Regulatory Organizations; NYSE Amex LLC; Notice of Filing and Immediate Effectiveness of...

    Science.gov (United States)

    2010-04-12

    ... have been prepared by the self-regulatory organization. Amex filed the proposal pursuant to Section 19.... Self-Regulatory Organization's Statement of the Terms of Substance of the Proposed Rule Change The... , at the Exchange's principal office and at the Commission's Public Reference Room. II. Self-Regulatory...

  3. Automated quality control in a file-based broadcasting workflow

    Science.gov (United States)

    Zhang, Lina

    2014-04-01

    Benefit from the development of information and internet technologies, television broadcasting is transforming from inefficient tape-based production and distribution to integrated file-based workflows. However, no matter how many changes have took place, successful broadcasting still depends on the ability to deliver a consistent high quality signal to the audiences. After the transition from tape to file, traditional methods of manual quality control (QC) become inadequate, subjective, and inefficient. Based on China Central Television's full file-based workflow in the new site, this paper introduces an automated quality control test system for accurate detection of hidden troubles in media contents. It discusses the system framework and workflow control when the automated QC is added. It puts forward a QC criterion and brings forth a QC software followed this criterion. It also does some experiments on QC speed by adopting parallel processing and distributed computing. The performance of the test system shows that the adoption of automated QC can make the production effective and efficient, and help the station to achieve a competitive advantage in the media market.

  4. A File Archival System

    Science.gov (United States)

    Fanselow, J. L.; Vavrus, J. L.

    1984-01-01

    ARCH, file archival system for DEC VAX, provides for easy offline storage and retrieval of arbitrary files on DEC VAX system. System designed to eliminate situations that tie up disk space and lead to confusion when different programers develop different versions of same programs and associated files.

  5. Effects of self-adjusting file, Mtwo, and ProTaper on the root canal wall.

    Science.gov (United States)

    Hin, Ellemieke S; Wu, Min-Kai; Wesselink, Paul R; Shemesh, Hagay

    2013-02-01

    The purpose of this ex vivo study was to observe the incidence of cracks in root dentin after root canal preparation with hand files, self-adjusting file (SAF), ProTaper, and Mtwo. One hundred extracted mandibular premolars with single canals were randomly selected. Two angulated radiographs were taken for each tooth, and the width of the canal was measured at 9 mm from the apex. Five groups of 20 teeth each were comparable in canal width. The control group was left unprepared. Four experimental groups were instrumented with hand files, ProTaper, Mtwo, and SAF. Roots were then sectioned horizontally and observed under a microscope. The presence of dentinal cracks and their location were noted. The difference between the experimental groups was analyzed with a χ(2) test. No cracks were observed in the control group. In the experimental groups, ProTaper, Mtwo, and SAF caused cracks in 35%, 25%, and 10% of teeth, respectively. The hand-file group did not show any dentinal cracks (P ProTaper and Mtwo caused more cracks than hand files (P .05). Instrumentation of root canals with SAF, Mtwo, and ProTaper could cause damage to root canal dentin. SAF has a tendency to cause less dentinal cracks as compared with ProTaper or Mtwo. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  6. Computer Forensics Method in Analysis of Files Timestamps in Microsoft Windows Operating System and NTFS File System

    Directory of Open Access Journals (Sweden)

    Vesta Sergeevna Matveeva

    2013-02-01

    Full Text Available All existing file browsers displays 3 timestamps for every file in file system NTFS. Nowadays there are a lot of utilities that can manipulate temporal attributes to conceal the traces of file using. However every file in NTFS has 8 timestamps that are stored in file record and used in detecting the fact of attributes substitution. The authors suggest a method of revealing original timestamps after replacement and automated variant of it in case of a set of files.

  7. Technical quality of root canal treatment of posterior teeth after rotary or hand preparation by fifth year undergraduate students, The University of Jordan.

    Science.gov (United States)

    Abu-Tahun, Ibrahim; Al-Rabab'ah, Mohammad A; Hammad, Mohammad; Khraisat, Ameen

    2014-12-01

    The aim of this study was to investigate the technical quality of root canal treatment provided by the undergraduate students as their first experience in molar endodontics using nickel-titanium (NiTi) files in a crown-down approach compared with stainless steel standard technique. This study was carried out by the fifth year undergraduate students attending peer review sessions as a part of their training programme, using two different questionnaires to assess the overall technical quality and potential problems regarding endodontic complications after root canal preparation with these two techniques. The overall results indicated a statistically significant difference in the performance of the two instrument techniques in difficult cases showing better performance of the NiTi system and mean rotary preparation time (P ProTaper rotary files, were able to prepare root canals faster with more preparation accuracy compared with canals of same teeth prepared with hand instruments. © 2014 Australian Society of Endodontology.

  8. Status of transactinium nuclear data in the Evaluated Nuclear Structure Data File

    International Nuclear Information System (INIS)

    Ewbank, W.B.

    1979-01-01

    The organization and program of the Nuclear Data Project are described. An Evaluated Nuclear Structure Data File (ENSDF) was designed to contain most of the data of nuclear structure physics. ENSDF includes adopted level information for all 1950 known nuclei, and detailed data for approximately 1500 decay schemes. File organization, management, and retrieval are reviewed. An international network of data evaluation centers has been organized to provide for a four-year cycle of ENSDF revisions. Standard retrieval and display programs can prepare various tables of specific data, which can serve as a good first approximation to a complete up-to-date compilation. Appendixes list, for A > 206, nuclear levels with lifetimes > or = 1 s, strong γ rays from radioisotopes (ordered by nuclide and energy), and strong α particle emissions (similarly ordered). 8 figures

  9. 76 FR 43679 - Filing via the Internet; Notice of Additional File Formats for efiling

    Science.gov (United States)

    2011-07-21

    ... list of acceptable file formats the four-character file extensions for Microsoft Office 2007/2010... files from Office 2007 or Office 2010 in an Office 2003 format prior to submission. Dated: July 15, 2011...

  10. Establishment of data base files of thermodynamic data developed by OECD/NEA. Pt. 1. Thermodynamic data of Np and Pu

    International Nuclear Information System (INIS)

    Yoshida, Yasushi; Sasamoto, Hiroshi

    2004-01-01

    Thermodynamic data base for compounds and complexes of actinides and fission products specialized in modeling requirements for safety assessments of radioactive waste disposal systems are being developed by NEA TDB project of OECD/NEA. In this project, relevant data bases for compounds and complexes of Np and Pu were published in 2001. JNC established the data base files available for geochemical calculation codes using these Np and Pu published data. And this procedure for establishment and contents of data base files are described in this report. These data base files were prepared as the formats of major geochemical codes PHREEQE, PHREEQC, EQ3/6 and Geochemist's workbench. Additionally modification for data in the thermodynamic data base files which had been already published by JNC was also done. This procedure and revised data bases are shown in the appendix of this report. (author)

  11. UPIN Group File

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Group Unique Physician Identifier Number (UPIN) File is the business entity file that contains the group practice UPIN and descriptive information. It does NOT...

  12. pTSC: Data file editing for the Tokamak Simulation Code

    International Nuclear Information System (INIS)

    Meiss, J.D.

    1987-09-01

    The code pTSC is an editor for the data files needed to run the Princeton Tokamak Simulation Code (TSC). pTSC utilizes the Macintosh interface to create a graphical environment for entering the data. As most of the data to run TSC consists of conductor positions, the graphical interface is especially appropriate

  13. 12 CFR 5.4 - Filing required.

    Science.gov (United States)

    2010-01-01

    ... CORPORATE ACTIVITIES Rules of General Applicability § 5.4 Filing required. (a) Filing. A depository institution shall file an application or notice with the OCC to engage in corporate activities and... advise an applicant through a pre-filing communication to send the filing or submission directly to the...

  14. A survey of experience-based preference of Nickel-Titanium rotary files and incidence of fracture among general dentists

    Directory of Open Access Journals (Sweden)

    WooCheol Lee

    2012-11-01

    Full Text Available Objectives The purpose was to investigate the preference and usage technique of NiTi rotary instruments and to retrieve data on the frequency of re-use and the estimated incidence of file separation in the clinical practice among general dentists. Materials and Methods A survey was disseminated via e-mail and on-site to 673 general dentists. The correlation between the operator's experience or preferred technique and frequency of re-use or incidence of file fracture was assessed. Results A total of 348 dentists (51.7% responded. The most frequently used NiTi instruments was ProFile (39.8% followed by ProTaper. The most preferred preparation technique was crown-down (44.6%. 54.3% of the respondents re-used NiTi files more than 10 times. There was a significant correlation between experience with NiTi files and the number of reuses (p = 0.0025. 54.6% of the respondents estimated experiencing file separation less than 5 times per year. The frequency of separation was significantly correlated with the instrumentation technique (p = 0.0003. Conclusions A large number of general dentists in Korea prefer to re-use NiTi rotary files. As their experience with NiTi files increased, the number of re-uses increased, while the frequency of breakage decreased. Operators who adopt the hybrid technique showed less tendency of separation even with the increased number of re-use.

  15. Assessment of apically extruded debris produced by the single-file ProTaper F2 technique under reciprocating movement.

    Science.gov (United States)

    De-Deus, Gustavo; Brandão, Maria Claudia; Barino, Bianca; Di Giorgi, Karina; Fidel, Rivail Antonio Sergio; Luna, Aderval Severino

    2010-09-01

    This study was designed to quantitatively evaluate the amount of dentin debris extruded from the apical foramen by comparing the conventional sequence of the ProTaper Universal nickel-titanium (NiTi) files with the single-file ProTaper F2 technique. Thirty mesial roots of lower molars were selected, and the use of different instrumentation techniques resulted in 3 groups (n=10 each). In G1, a crown-down hand-file technique was used, and in G2 conventional ProTaper Universal technique was used. In G3, ProTaper F2 file was used in a reciprocating motion. The apical finish preparation was equivalent to ISO size 25. An apparatus was used to evaluate the apically extruded debris. Statistical analysis was performed using 1-way analysis of variance and Tukey multiple comparisons. No significant difference was found in the amount of the debris extruded between the conventional sequence of the ProTaper Universal NiTi files and the single-file ProTaper F2 technique (P>.05). In contrast, the hand instrumentation group extruded significantly more debris than both NiTi groups (P<.05). The present results yielded favorable input for the F2 single-file technique in terms of apically extruded debris, inasmuch as it is the most simple and cost-effective instrumentation approach. Copyright (c) 2010 Mosby, Inc. All rights reserved.

  16. Huygens file service and storage architecture

    NARCIS (Netherlands)

    Bosch, H.G.P.; Mullender, Sape J.; Stabell-Kulo, Tage; Stabell-Kulo, Tage

    1993-01-01

    The Huygens file server is a high-performance file server which is able to deliver multi-media data in a timely manner while also providing clients with ordinary “Unix” like file I/O. The file server integrates client machines, file servers and tertiary storage servers in the same storage

  17. Huygens File Service and Storage Architecture

    NARCIS (Netherlands)

    Bosch, H.G.P.; Mullender, Sape J.; Stabell-Kulo, Tage; Stabell-Kulo, Tage

    1993-01-01

    The Huygens file server is a high-performance file server which is able to deliver multi-media data in a timely manner while also providing clients with ordinary “Unix” like file I/O. The file server integrates client machines, file servers and tertiary storage servers in the same storage

  18. Apically extruded dentin debris by reciprocating single-file and multi-file rotary system.

    Science.gov (United States)

    De-Deus, Gustavo; Neves, Aline; Silva, Emmanuel João; Mendonça, Thais Accorsi; Lourenço, Caroline; Calixto, Camila; Lima, Edson Jorge Moreira

    2015-03-01

    This study aims to evaluate the apical extrusion of debris by the two reciprocating single-file systems: WaveOne and Reciproc. Conventional multi-file rotary system was used as a reference for comparison. The hypotheses tested were (i) the reciprocating single-file systems extrude more than conventional multi-file rotary system and (ii) the reciprocating single-file systems extrude similar amounts of dentin debris. After solid selection criteria, 80 mesial roots of lower molars were included in the present study. The use of four different instrumentation techniques resulted in four groups (n = 20): G1 (hand-file technique), G2 (ProTaper), G3 (WaveOne), and G4 (Reciproc). The apparatus used to evaluate the collection of apically extruded debris was typical double-chamber collector. Statistical analysis was performed for multiple comparisons. No significant difference was found in the amount of the debris extruded between the two reciprocating systems. In contrast, conventional multi-file rotary system group extruded significantly more debris than both reciprocating groups. Hand instrumentation group extruded significantly more debris than all other groups. The present results yielded favorable input for both reciprocation single-file systems, inasmuch as they showed an improved control of apically extruded debris. Apical extrusion of debris has been studied extensively because of its clinical relevance, particularly since it may cause flare-ups, originated by the introduction of bacteria, pulpal tissue, and irrigating solutions into the periapical tissues.

  19. Building a parallel file system simulator

    International Nuclear Information System (INIS)

    Molina-Estolano, E; Maltzahn, C; Brandt, S A; Bent, J

    2009-01-01

    Parallel file systems are gaining in popularity in high-end computing centers as well as commercial data centers. High-end computing systems are expected to scale exponentially and to pose new challenges to their storage scalability in terms of cost and power. To address these challenges scientists and file system designers will need a thorough understanding of the design space of parallel file systems. Yet there exist few systematic studies of parallel file system behavior at petabyte- and exabyte scale. An important reason is the significant cost of getting access to large-scale hardware to test parallel file systems. To contribute to this understanding we are building a parallel file system simulator that can simulate parallel file systems at very large scale. Our goal is to simulate petabyte-scale parallel file systems on a small cluster or even a single machine in reasonable time and fidelity. With this simulator, file system experts will be able to tune existing file systems for specific workloads, scientists and file system deployment engineers will be able to better communicate workload requirements, file system designers and researchers will be able to try out design alternatives and innovations at scale, and instructors will be able to study very large-scale parallel file system behavior in the class room. In this paper we describe our approach and provide preliminary results that are encouraging both in terms of fidelity and simulation scalability.

  20. 76 FR 52323 - Combined Notice of Filings; Filings Instituting Proceedings

    Science.gov (United States)

    2011-08-22

    .... Applicants: Young Gas Storage Company, Ltd. Description: Young Gas Storage Company, Ltd. submits tariff..., but intervention is necessary to become a party to the proceeding. The filings are accessible in the.... More detailed information relating to filing requirements, interventions, protests, and service can be...

  1. Ground-Based Global Navigation Satellite System Combined Broadcast Ephemeris Data (daily files) from NASA CDDIS

    Data.gov (United States)

    National Aeronautics and Space Administration — This dataset consists of ground-based Global Navigation Satellite System (GNSS) Combined Broadcast Ephemeris Data (daily files of all distinct navigation messages...

  2. 75 FR 61479 - Kendall Head Tidal Energy Project; Notice of Preliminary Permit Application Accepted for Filing...

    Science.gov (United States)

    2010-10-05

    ... Tidal Energy Project; Notice of Preliminary Permit Application Accepted for Filing and Soliciting... Federal Power Act, proposing to study the feasibility of the Kendall Head Tidal Energy Project, located in.... The proposed project would consist of: (1) 4 OCGen\\TM\\ hydrokinetic tidal devices each consisting of...

  3. The design and analysis of salmonid tagging studies in the Columbia Basin. Volume 10: Instructional guide to using program CaptHist to create SURPH files for survival analysis using PTAGIS data files

    International Nuclear Information System (INIS)

    Westhagen, P.; Skalski, J.

    1997-12-01

    The SURPH program is a valuable tool for estimating survivals and capture probabilities of fish outmigrations on the Snake and Columbia Rivers. Using special data files, SURPH computes reach to reach statistics for any release group passing a system of detection sites. Because the data must be recorded for individual fish, PIT tag data is best suited for use as input. However, PIT tag data as available from PTAGIS comes in a form that is not ready for use as SURPH input. SURPH requires a capture history for each fish. A capture history consists of a series of fields, one for each detection site, that has a code for whether the fish was detected and returned to the river, detected and removed, or not detected. For the PTAGIS data to be usable by SURPH it must be pre-processed. The data must be condensed down to one line per fish with the relevant detection information from the PTAGIS file represented compactly on each line. In addition, the PTAGIS data file coil information must be passed through a series of logic algorithms to determine whether or not a fish is returned to the river after detection. Program CaptHist was developed to properly pre-process the PTAGIS data files for input to program SURPH. This utility takes PTAGIS data files as input and creates a SURPH data file as well as other output including travel time records, detection date records, and a data error file. CaptHist allows a user to download PTAGIS files and easily process the data for use with SURPH

  4. Evaluated neutronic file for indium

    International Nuclear Information System (INIS)

    Smith, A.B.; Chiba, S.; Smith, D.L.; Meadows, J.W.; Guenther, P.T.; Lawson, R.D.; Howerton, R.J.

    1990-01-01

    A comprehensive evaluated neutronic data file for elemental indium is documented. This file, extending from 10 -5 eV to 20 MeV, is presented in the ENDF/B-VI format, and contains all neutron-induced processes necessary for the vast majority of neutronic applications. In addition, an evaluation of the 115 In(n,n') 116m In dosimetry reaction is presented as a separate file. Attention is given in quantitative values, with corresponding uncertainty information. These files have been submitted for consideration as a part of the ENDF/B-VI national evaluated-file system. 144 refs., 10 figs., 4 tabs

  5. FHEO Filed Cases

    Data.gov (United States)

    Department of Housing and Urban Development — The dataset is a list of all the Title VIII fair housing cases filed by FHEO from 1/1/2007 - 12/31/2012 including the case number, case name, filing date, state and...

  6. Influence of File Motion on Shaping, Apical Debris Extrusion and Dentinal Defects: A Critical Review.

    Science.gov (United States)

    Pedrinha, Victor Feliz; Brandão, Juliana Melo da Silva; Pessoa, Oscar Faciola; Rodrigues, Patrícia de Almeida

    2018-01-01

    Advances in endodontics have enabled the evolution of file manufacturing processes, improving performance beyond that of conventional files. In the present study, systems manufactured using state of the art methods and possessing special properties related to NiTi alloys ( i.e ., CM-Wire, M-Wire and R-Phase) were selected. The aim of this review was to provide a detailed analysis of the literature about the relationship between recently introduced NiTi files with different movement kinematics and shaping ability, apical extrusion of debris and dentin defects in root canal preparations. From March 2016 to January 2017, electronic searches were conducted in the PubMed and SCOPUS databases for articles published since January 2010. In vitro studies performed on extracted human teeth and published in English were considered for this review. Based on the inclusion criteria, 71 papers were selected for the analysis of full-text copies. Specific analysis was performed on 45 articles describing the effects of reciprocating, continuous and adaptive movements on the WaveOne Gold, Reciproc, HyFlex CM and Twisted File Adaptive systems. A wide range of testing conditions and methodologies have been used to compare the systems. Due the controversies among the results, the characteristics of the files used, such as their design and alloys, appear to be inconsistent to determine the best approach.

  7. 78 FR 51765 - Self-Regulatory Organizations; New York Stock Exchange LLC; Notice of Filing and Immediate...

    Science.gov (United States)

    2013-08-21

    ... matters. Many of the fees vary depending on the amount of such services used, so that as the level of...-Regulatory Organizations; New York Stock Exchange LLC; Notice of Filing and Immediate Effectiveness of... described in Items I and II below, which Items have been prepared by the self-regulatory organization. The...

  8. "The NASA Sci Files": The Case of the Biological Biosphere. [Videotape].

    Science.gov (United States)

    National Aeronautics and Space Administration, Hampton, VA. Langley Research Center.

    The NASA Science Files is a series of instructional programs consisting of broadcast, print, and online elements. Emphasizing standards-based instruction, problem-based learning, and science as inquiry, the series seeks to motivate students in grades 3-5 to become critical thinkers and active problem solvers. Each program supports the national…

  9. Apical extrusion of bacteria when using reciprocating single-file and rotary multifile instrumentation systems.

    Science.gov (United States)

    Tinoco, J M; De-Deus, G; Tinoco, E M B; Saavedra, F; Fidel, R A S; Sassone, L M

    2014-06-01

    To evaluate ex vivo, apical bacterial extrusion associated with two reciprocating single-file systems (WaveOne and Reciproc) compared with a conventional multifile rotary system (BioRace). Forty-five human single-rooted mandibular incisors were used. Endodontic access cavities were prepared, and root canals were contaminated with an Enterococcus faecalis suspension. Following incubation at 37 °C for thirty days, the contaminated teeth were divided into three groups of 15 specimens each (G1 - Reciproc, G2 - WaveOne and G3 - BioRace). Positive and negative controls consisted of 5 infected teeth and 3 uninfected incisors that were instrumented with one of the tested NiTi systems, respectively. Bacteria extruded from the apical foramen during instrumentation were collected into vials containing 0.9% NaCl. The microbiological samples were taken from the vials and incubated in brain heart agar medium for 24 h. The resulting bacterial titre, in colony-forming units (CFU) per mL, was determined, and these data were analysed by Wilcoxon matched-pairs signed rank test and Kruskal-Wallis H-test. The level of significance was set at α = 0.05. No significant difference was found in the number of CFU between the two reciprocating systems (P = 0.41). The conventional multifile rotary system group was associated with significantly higher CFU than both of the two reciprocating groups (P = 0.01). All instrumentation systems extruded bacteria beyond the foramen. However, both reciprocating single-file systems extruded fewer bacteria apically than the conventional multifile rotary system. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  10. Ground-Based Global Navigation Satellite System (GNSS) GLONASS Broadcast Ephemeris Data (hourly files) from NASA CDDIS

    Data.gov (United States)

    National Aeronautics and Space Administration — This dataset consists of ground-based Global Navigation Satellite System (GNSS) GLObal NAvigation Satellite System (GLONASS) Broadcast Ephemeris Data (hourly files)...

  11. Comparison of dentinal damage induced by different nickel-titanium rotary instruments during canal preparation: An in vitro study.

    Science.gov (United States)

    Garg, Shiwani; Mahajan, Pardeep; Thaman, Deepa; Monga, Prashant

    2015-01-01

    To compare dentinal damage caused by hand and rotary nickel-titanium instruments using ProTaper, K3 Endo, and Easy RaCe systems after root canal preparation. One hundred and fifty freshly extracted mandibular premolars were randomly divided into five experimental groups of 30 teeth each and biomechanical preparation was done: Group 1 with unprepared teeth; Group 2 were prepared with hand files; Group 3 with ProTaper rotary instruments; Group 4 with K3 rotary; Group 5 with Easy RaCe rotary instruments. Then, roots were cut horizontally at 3, 6, and 9 mm from apex and were viewed under stereomicroscope. The presence of dentinal defects was noted. Groups were analyzed with the Chi-square test. Significant difference was seen between groups. No defects were found in unprepared roots and those prepared with hand files. ProTaper, K3 rotary, and Easy RaCe preparations resulted in dentinal defects in 23.3%, 10%, and 16.7% of teeth, respectively. More defects were shown in coronal and middle sections, and no defect was seen in apical third. The present study revealed that use of rotary instruments could result in an increased chance for dentinal defects as compared to hand instrumentation.

  12. 76 FR 62092 - Filing Procedures

    Science.gov (United States)

    2011-10-06

    ... INTERNATIONAL TRADE COMMISSION Filing Procedures AGENCY: International Trade Commission. ACTION: Notice of issuance of Handbook on Filing Procedures. SUMMARY: The United States International Trade Commission (``Commission'') is issuing a Handbook on Filing Procedures to replace its Handbook on Electronic...

  13. 12 CFR 1780.9 - Filing of papers.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Filing of papers. 1780.9 Section 1780.9 Banks... papers. (a) Filing. Any papers required to be filed shall be addressed to the presiding officer and filed... Director or the presiding officer. All papers filed by electronic media shall also concurrently be filed in...

  14. Effect of canal length and curvature on working length alteration with WaveOne reciprocating files.

    Science.gov (United States)

    Berutti, Elio; Chiandussi, Giorgio; Paolino, Davide Salvatore; Scotti, Nicola; Cantatore, Giuseppe; Castellucci, Arnaldo; Pasqualini, Damiano

    2011-12-01

    This study evaluated the working length (WL) modification after instrumentation with WaveOne Primary (Dentsply Maillefer, Ballaigues, Switzerland) reciprocating files and the incidence of overinstrumentation in relation to the initial WL. Thirty-two root canals of permanent teeth were used. The angles of curvature of the canals were calculated on digital radiographs. The initial WL with K-files was transferred to the matched WaveOne Primary reciprocating files. After glide paths were established with PathFile (Dentsply Maillefer, Ballaigues, Switzerland), canals were shaped with WaveOne Primary referring to the initial WL. The difference between the postinstrumentation canal length and the initial canal length was analyzed by using a fiberoptic inspection microscope. Data were analyzed with a balanced 2-way factorial analysis of variance (P < .05). Referring to the initial WL, 24 of 32 WaveOne Primary files projected beyond the experimental apical foramen (minimum-maximum, 0.14-0.76 mm). A significant decrease in the canal length after instrumentation (95% confidence interval ranging from -0.34 mm to -0.26 mm) was detected. The canal curvature significantly influenced the WL variation (F(1) = 30.65, P < .001). The interaction between the initial canal length and the canal curvature was statistically significant (F(2) = 4.38, P = .014). Checking the WL before preparation of the apical third of the root canal is recommended when using the new WaveOne NiTi single-file system. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  15. Apically extruded debris with reciprocating single-file and full-sequence rotary instrumentation systems.

    Science.gov (United States)

    Bürklein, Sebastian; Schäfer, Edgar

    2012-06-01

    The purpose of this in vitro study was to assess the amount of apically extruded debris using rotary and reciprocating nickel-titanium instrumentation systems. Eighty human mandibular central incisors were randomly assigned to 4 groups (n = 20 teeth per group). The root canals were instrumented according to the manufacturers' instructions using the 2 reciprocating single-file systems Reciproc (VDW, Munich, Germany) and WaveOne (Dentsply Maillefer, Ballaigues, Switzerland) and the 2 full-sequence rotary Mtwo (VDW, Munich, Germany) and ProTaper (Dentsply Maillefer, Ballaigues, Switzerland) instruments. Bidistilled water was used as irrigant. The apically extruded debris was collected in preweighted glass vials using the Myers and Montgomery method. After drying, the mean weight of debris was assessed with a microbalance and statistically analyzed using analysis of variance and the post hoc Student-Newman-Keuls test. The time required to prepare the canals with the different instruments was also recorded. The reciprocating files produced significantly more debris compared with both rotary systems (P rotary instruments (P > .05), the reciprocating single-file system Reciproc produced significantly more debris compared with all other instruments (P Instrumentation was significantly faster using Reciproc than with all other instrument (P rotary instrumentation was associated with less debris extrusion compared with the use of reciprocating single-file systems. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  16. The Galley Parallel File System

    Science.gov (United States)

    Nieuwejaar, Nils; Kotz, David

    1996-01-01

    Most current multiprocessor file systems are designed to use multiple disks in parallel, using the high aggregate bandwidth to meet the growing I/0 requirements of parallel scientific applications. Many multiprocessor file systems provide applications with a conventional Unix-like interface, allowing the application to access multiple disks transparently. This interface conceals the parallelism within the file system, increasing the ease of programmability, but making it difficult or impossible for sophisticated programmers and libraries to use knowledge about their I/O needs to exploit that parallelism. In addition to providing an insufficient interface, most current multiprocessor file systems are optimized for a different workload than they are being asked to support. We introduce Galley, a new parallel file system that is intended to efficiently support realistic scientific multiprocessor workloads. We discuss Galley's file structure and application interface, as well as the performance advantages offered by that interface.

  17. The evaluated gamma-ray activation file (EGAF)

    International Nuclear Information System (INIS)

    Firestone, R.B.; Molnar, G.L.; Revay, Zs.; Belgya, T.; McNabb, D.P.; Sleaford, B.W.

    2004-01-01

    The Evaluated Gamma-ray Activation File (EGAF), a new database of prompt and delayed neutron capture g-ray cross sections, has been prepared as part of an International Atomic Energy Agency (IAEA) Coordinated Research Project to develop a ''Database of Prompt Gamma-rays from Slow Neutron Capture for Elemental Analysis.'' Recent elemental g-ray cross-section measurements performed with the guided neutron beam at the Budapest Reactor have been combined with data from the literature to produce the EGAF database. EGAF contains thermal cross sections for ∼ 35,000 prompt and delayed g-rays from 262 isotopes. New precise total thermal radiative cross sections have been derived for many isotopes from the primary and secondary gamma-ray cross sections and additional level scheme data. An IAEA TECDOC describing the EGAF evaluation and tabulating the most prominent g-rays will be published in 2004. The TECDOC will include a CD-ROM containing the EGAF database in both ENSDF and tabular formats with an interactive viewer for searching and displaying the data. The Isotopes Project, Lawrence Berkeley National Laboratory continues to maintain and update the EGAF file. These data are available on the Internet from both the IAEA and Isotopes Project websites

  18. Ground-Based Global Navigation Satellite System (GNSS) GPS Broadcast Ephemeris Data (daily files) from NASA CDDIS

    Data.gov (United States)

    National Aeronautics and Space Administration — This dataset consists of ground-based Global Navigation Satellite System (GNSS) GPS Broadcast Ephemeris Data (daily files) from the NASA Crustal Dynamics Data...

  19. FTP: Full-Text Publishing?

    Science.gov (United States)

    Jul, Erik

    1992-01-01

    Describes the use of file transfer protocol (FTP) on the INTERNET computer network and considers its use as an electronic publishing system. The differing electronic formats of text files are discussed; the preparation and access of documents are described; and problems are addressed, including a lack of consistency. (LRW)

  20. 78 FR 21930 - Aquenergy Systems, Inc.; Notice of Intent To File License Application, Filing of Pre-Application...

    Science.gov (United States)

    2013-04-12

    ... Systems, Inc.; Notice of Intent To File License Application, Filing of Pre-Application Document, and Approving Use of the Traditional Licensing Process a. Type of Filing: Notice of Intent to File License...: November 11, 2012. d. Submitted by: Aquenergy Systems, Inc., a fully owned subsidiaries of Enel Green Power...

  1. Comparative evaluation of effect of rotary and reciprocating single-file systems on pericervical dentin: A cone-beam computed tomography study.

    Science.gov (United States)

    Zinge, Priyanka Ramdas; Patil, Jayaprakash

    2017-01-01

    The aim of this study is to evaluate and compare the effect of one shape, Neolix rotary single-file systems and WaveOne, Reciproc reciprocating single-file systems on pericervical dentin (PCD) using cone-beam computed tomography (CBCT). A total of 40 freshly extracted mandibular premolars were collected and divided into two groups, namely, Group A - Rotary: A 1 - Neolix and A 2 - OneShape and Group B - Reciprocating: B 1 - WaveOne and B 2 - Reciproc. Preoperative scans of each were taken followed by conventional access cavity preparation and working length determination with 10-k file. Instrumentation of the canal was done according to the respective file system, and postinstrumentation CBCT scans of teeth were obtained. 90 μm thick slices were obtained 4 mm apical and coronal to the cementoenamel junction. The PCD thickness was calculated as the shortest distance from the canal outline to the closest adjacent root surface, which was measured in four surfaces, i.e., facial, lingual, mesial, and distal for all the groups in the two obtained scans. There was no significant difference found between rotary single-file systems and reciprocating single-file systems in their effect on PCD, but in Group B 2 , there was most significant loss of tooth structure in the mesial, lingual, and distal surface ( P file system removes more PCD as compared to other experimental groups, whereas Neolix single file system had the least effect on PCD.

  2. 12 CFR 16.33 - Filing fees.

    Science.gov (United States)

    2010-01-01

    ... Banking COMPTROLLER OF THE CURRENCY, DEPARTMENT OF THE TREASURY SECURITIES OFFERING DISCLOSURE RULES § 16.33 Filing fees. (a) Filing fees must accompany certain filings made under the provisions of this part... Comptroller of the Currency Fees published pursuant to § 8.8 of this chapter. (b) Filing fees must be paid by...

  3. 75 FR 4689 - Electronic Tariff Filings

    Science.gov (United States)

    2010-01-29

    ... elements ``are required to properly identify the nature of the tariff filing, organize the tariff database... (or other pleading) and the Type of Filing code chosen will be resolved in favor of the Type of Filing...'s wish expressed in its transmittal letter or in other pleadings, the Commission may not review a...

  4. Ground-Based Global Navigation Satellite System Mixed Broadcast Ephemeris Data (sub-hourly files) from NASA CDDIS

    Data.gov (United States)

    National Aeronautics and Space Administration — This dataset consists of ground-based Global Navigation Satellite System (GNSS) Mixed Broadcast Ephemeris Data (sub-hourly files) from the NASA Crustal Dynamics Data...

  5. 78 FR 75554 - Combined Notice of Filings

    Science.gov (United States)

    2013-12-12

    ...-000. Applicants: Young Gas Storage Company, Ltd. Description: Young Fuel Reimbursement Filing to be.... Protests may be considered, but intervention is necessary to become a party to the proceeding. eFiling is... qualifying facilities filings can be found at: http://www.ferc.gov/docs-filing/efiling/filing-req.pdf . For...

  6. Small file aggregation in a parallel computing system

    Science.gov (United States)

    Faibish, Sorin; Bent, John M.; Tzelnic, Percy; Grider, Gary; Zhang, Jingwang

    2014-09-02

    Techniques are provided for small file aggregation in a parallel computing system. An exemplary method for storing a plurality of files generated by a plurality of processes in a parallel computing system comprises aggregating the plurality of files into a single aggregated file; and generating metadata for the single aggregated file. The metadata comprises an offset and a length of each of the plurality of files in the single aggregated file. The metadata can be used to unpack one or more of the files from the single aggregated file.

  7. 5 CFR 1203.13 - Filing pleadings.

    Science.gov (United States)

    2010-01-01

    ... delivery, by facsimile, or by e-filing in accordance with § 1201.14 of this chapter. If the document was... submitted by e-filing, it is considered to have been filed on the date of electronic submission. (e... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Filing pleadings. 1203.13 Section 1203.13...

  8. PFS: a distributed and customizable file system

    NARCIS (Netherlands)

    Bosch, H.G.P.; Mullender, Sape J.

    1996-01-01

    In this paper we present our ongoing work on the Pegasus File System (PFS), a distributed and customizable file system that can be used for off-line file system experiments and on-line file system storage. PFS is best described as an object-oriented component library from which either a true file

  9. 76 FR 61351 - Combined Notice of Filings #1

    Science.gov (United States)

    2011-10-04

    ... MBR Baseline Tariff Filing to be effective 9/22/2011. Filed Date: 09/22/2011. Accession Number... submits tariff filing per 35.1: ECNY MBR Re-File to be effective 9/22/2011. Filed Date: 09/22/2011... Industrial Energy Buyers, LLC submits tariff filing per 35.1: NYIEB MBR Re-File to be effective 9/22/2011...

  10. Deceit: A flexible distributed file system

    Science.gov (United States)

    Siegel, Alex; Birman, Kenneth; Marzullo, Keith

    1989-01-01

    Deceit, a distributed file system (DFS) being developed at Cornell, focuses on flexible file semantics in relation to efficiency, scalability, and reliability. Deceit servers are interchangeable and collectively provide the illusion of a single, large server machine to any clients of the Deceit service. Non-volatile replicas of each file are stored on a subset of the file servers. The user is able to set parameters on a file to achieve different levels of availability, performance, and one-copy serializability. Deceit also supports a file version control mechanism. In contrast with many recent DFS efforts, Deceit can behave like a plain Sun Network File System (NFS) server and can be used by any NFS client without modifying any client software. The current Deceit prototype uses the ISIS Distributed Programming Environment for all communication and process group management, an approach that reduces system complexity and increases system robustness.

  11. Evaluation of Single File Systems Reciproc, Oneshape, and WaveOne using Cone Beam Computed Tomography –An In Vitro Study

    Science.gov (United States)

    Dhingra, Annil; Miglani, Anjali

    2015-01-01

    Background Successful endodontic therapy depends on many factor, one of the most important step in any root canal treatment is root canal preparation. In addition, respecting the original shape of the canal is of the same importance; otherwise, canal aberrations such as transportation will be created. Aim The purpose of this study is to compare and evaluate Reciprocating WaveOne ,Reciproc and Rotary Oneshape Single File Instrumentation System On Cervical Dentin Thickness, Cross Sectional Area and Canal Transportation on First Mandibular Molar Using Cone Beam Computed Tomography. Materials and Methods Sixty Mandibular First Molars extracted due to periodontal reason was collected from the Department of Oral and Maxillofacial. Teeth were prepared using one rotary and two reciprocating single file system. Teeth were divided into 3 groups 20 teeth in each group. Pre instrumentation and Post instrumentation scans was done and evaluated for three parameters Canal Transportation, Cervical Dentinal Thickness, Cross-sectional Area. Results were analysed statistically using ANOVA, Post-Hoc Tukey analysis. Results The change in cross-sectional area after filing showed significant difference at 0mm, 1mm, 2mm and 7mm (pfile system over a distance of 7 mm (starting from 0mm and then evaluation at 1mm, 2mm, 3mm, 5mm and 7mm), the results showed a significant difference among the file systems at various lengths (p= 0.014, 0.046, 0.004, 0.028, 0.005 & 0.029 respectively). Mean value of cervical dentinal removal is maximum at all the levels for oneshape and minimum for waveone showing the better quality of waveone and reciproc over oneshape file system. Significant difference was found at 9mm, 11mm and 12mm between all the three file systems (p<0.001,< 0.001, <0.001). Conclusion It was concluded that reciprocating motion is better than rotary motion in all the three parameters Canal Transportation, Cross-sectional Area, Cervical Dentinal Thickness. PMID:26023639

  12. DMFC Performance of Polymer Electrolyte Membranes Prepared from a Graft-Copolymer Consisting of a Polysulfone Main Chain and Styrene Sulfonic Acid Side Chains

    Directory of Open Access Journals (Sweden)

    Nobutaka Endo

    2016-08-01

    Full Text Available Polymer electrolyte membranes (PEMs for direct methanol fuel cell (DMFC applications were prepared from a graft-copolymer (PSF-g-PSSA consisting of a polysulfone (PSF main chain and poly(styrene sulfonic acid (PSSA side chains with various average distances between side chains (Lav and side chain lengths (Lsc. The polymers were synthesized by grafting ethyl p-styrenesulfonate (EtSS on macro-initiators of chloromethylated polysulfone with different contents of chloromethyl (CM groups, and by changing EtSS content in the copolymers by using atom transfer radical polymerization (ATRP. The DMFC performance tests using membrane electrode assemblis (MEAs with the three types of the PEMs revealed that: a PSF-g-PSSA PEM (SF-6 prepared from a graft copolymer with short average distances between side chains (Lav and medium Lsc had higher DMFC performance than PEMs with long Lav and long Lsc or with short Lav and short Lsc. SF-6 had about two times higher PDmax (68.4 mW/cm2 than Nafion® 112 at 30 wt % of methanol concentration. Furthermore, it had 58.2 mW/cm2 of PDmax at 50 wt % of methanol concentration because of it has the highest proton selectivity during DMFC operation of all the PSF-g-PSSA PEMs and Nafion® 112.

  13. 10 CFR 110.89 - Filing and service.

    Science.gov (United States)

    2010-01-01

    ...: Rulemakings and Adjudications Staff or via the E-Filing system, following the procedure set forth in 10 CFR 2.302. Filing by mail is complete upon deposit in the mail. Filing via the E-Filing system is completed... residence with some occupant of suitable age and discretion; (2) Following the requirements for E-Filing in...

  14. 49 CFR 1104.6 - Timely filing required.

    Science.gov (United States)

    2010-10-01

    ... offers next day delivery to Washington, DC. If the e-filing option is chosen (for those pleadings and documents that are appropriate for e-filing, as determined by reference to the information on the Board's Web site), then the e-filed pleading or document is timely filed if the e-filing process is completed...

  15. DICOM supported sofware configuration by XML files

    International Nuclear Information System (INIS)

    LucenaG, Bioing Fabian M; Valdez D, Andres E; Gomez, Maria E; Nasisi, Oscar H

    2007-01-01

    A method for the configuration of informatics systems that provide support to DICOM standards using XML files is proposed. The difference with other proposals is base on that this system does not code the information of a DICOM objects file, but codes the standard itself in an XML file. The development itself is the format for the XML files mentioned, in order that they can support what DICOM normalizes for multiple languages. In this way, the same configuration file (or files) can be use in different systems. Jointly the XML configuration file generated, we wrote also a set of CSS and XSL files. So the same file can be visualized in a standard browser, as a query system of DICOM standard, emerging use, that did not was a main objective but brings a great utility and versatility. We exposed also some uses examples of the configuration file mainly in relation with the load of DICOM information objects. Finally, at the conclusions we show the utility that the system has already provided when the edition of DICOM standard changes from 2006 to 2007

  16. Generation of Gaussian 09 Input Files for the Computation of 1H and 13C NMR Chemical Shifts of Structures from a Spartan’14 Conformational Search

    OpenAIRE

    sprotocols

    2014-01-01

    Authors: Spencer Reisbick & Patrick Willoughby ### Abstract This protocol describes an approach to preparing a series of Gaussian 09 computational input files for an ensemble of conformers generated in Spartan’14. The resulting input files are necessary for computing optimum geometries, relative conformer energies, and NMR shielding tensors using Gaussian. Using the conformational search feature within Spartan’14, an ensemble of conformational isomers was obtained. To convert the str...

  17. 12 CFR 908.25 - Filing of papers.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Filing of papers. 908.25 Section 908.25 Banks... RULES OF PRACTICE AND PROCEDURE IN HEARINGS ON THE RECORD General Rules § 908.25 Filing of papers. (a) Filing. Any papers required to be filed shall be addressed to the presiding officer and filed with the...

  18. Apical Transportation, Centering Ability, and Cleaning Effectiveness of Reciprocating Single-file System Associated with Different Glide Path Techniques.

    Science.gov (United States)

    de Carvalho, Guilherme Moreira; Sponchiado Junior, Emílio Carlos; Garrido, Angela Delfina Bittencourt; Lia, Raphael Carlos Comelli; Garcia, Lucas da Fonseca Roberti; Marques, André Augusto Franco

    2015-12-01

    The aim of this study was to evaluate the apical transportation, the centering ability, and the cleaning effectiveness of a reciprocating single-file system associated to different glide path techniques. The mesial root canals of 52 mandibular molars were randomly distributed into 4 groups (n = 13) according to the different glide path techniques used before biomechanical preparation with Reciproc System (RS): KF/RS (sizes 10 and 15 K-files), NGP/RS (no glide path, only reciprocating system), PF/RS (sizes 13, 16, and 19 PathFile instruments), and NP (no preparation). Cone-beam computed tomography analysis was performed before and after instrumentation for apical third images acquisition. Apical transportation and its direction were evaluated by using the formula D = (X1 - X2) - (Y1 - Y2), and the centering ability was analyzed by the formula CC = (X1 - X2/Y1 - Y2 or Y1 - Y2/X1 - X2). The samples were submitted to histologic processing and analyzed under a digital microscope for debris quantification. The values were statistically analyzed (Kruskal-Wallis, the Dunn multiple comparisons test, P .05). Groups had a tendency toward transportation in the mesial direction. No technique had perfect centering ability (=1.0), with no significant difference among them. KF/RS had larger amount of debris, with statistically significant difference in comparison with NGP/RS (P > .05). The different glide path techniques promoted minimal apical transportation, and the reciprocating single-file system tested remained relatively centralized within the root canal. Also, the different techniques interfered in the cleaning effectiveness of the reciprocating system. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. PFS: a distributed and customizable file system

    OpenAIRE

    Bosch, H.G.P.; Mullender, Sape J.

    1996-01-01

    In this paper we present our ongoing work on the Pegasus File System (PFS), a distributed and customizable file system that can be used for off-line file system experiments and on-line file system storage. PFS is best described as an object-oriented component library from which either a true file system or a file-system simulator can be constructed. Each of the components in the library is easily replaced by another implementation to accommodate a wide range of applications.

  20. Introduction [International Reactor Dosimetry File 2002 (IRDF-2002)

    International Nuclear Information System (INIS)

    Paviotti-Corcuera, R.; Zolnay, E.M.

    2006-01-01

    The most recently tested version of the International Reactor Dosimetry File, IRDF-90 Version 2 (IRDF-90.2), was released in 1993. Most of the evaluations used in this file were prepared in the mid-1980s, and in the meantime a large amount of new experimental data has become available, along with two new national reactor dosimetry libraries (the Russian Reactor Dosimetry File (RRDF-98) and the Japanese Evaluated Nuclear Data Library (JENDL/D-99)). The cross-sections and related uncertainties for several reactions in these libraries may be of better quality than the data in the older IRDF-90 file. These developments have resulted in different cross-section values being applied to the evaluation of experimental data, creating difficulties in comparing the results of reactor dosimetry calculations from the same types of nuclear facility. Therefore, there has been a strong demand from the reactor dosimetry community for an updated and standardized version of the IRDF. The IAEA has in the past supported similar efforts to improve the quality of data for reactor dosimetry applications. A major objective of the present data development project was to prepare and distribute a standardized, updated and tested reactor dosimetry cross-section library accompanied by uncertainty information (IRDF-2002) for use in service life assessments of nuclear power reactors. In order to achieve this objective, two technical meetings were organized. Both meetings were held at the IAEA in Vienna. The first meeting took place from 27 to 29 August 2002, the second from 1 to 3 October 2003. Recommendations were made concerning the following topics and the preparation of the library: reactions to be included, requirements for new evaluations or revisions, nuclear decay data, radiation damage data, testing of the data in benchmark fields and inclusion of computer codes. The participants emphasized that good quality nuclear data for reactor dosimetry are essential to improve assessments of the

  1. Solving data-at-rest for the storage and retrieval of files in ad hoc networks

    Science.gov (United States)

    Knobler, Ron; Scheffel, Peter; Williams, Jonathan; Gaj, Kris; Kaps, Jens-Peter

    2013-05-01

    Based on current trends for both military and commercial applications, the use of mobile devices (e.g. smartphones and tablets) is greatly increasing. Several military applications consist of secure peer to peer file sharing without a centralized authority. For these military applications, if one or more of these mobile devices are lost or compromised, sensitive files can be compromised by adversaries, since COTS devices and operating systems are used. Complete system files cannot be stored on a device, since after compromising a device, an adversary can attack the data at rest, and eventually obtain the original file. Also after a device is compromised, the existing peer to peer system devices must still be able to access all system files. McQ has teamed with the Cryptographic Engineering Research Group at George Mason University to develop a custom distributed file sharing system to provide a complete solution to the data at rest problem for resource constrained embedded systems and mobile devices. This innovative approach scales very well to a large number of network devices, without a single point of failure. We have implemented the approach on representative mobile devices as well as developed an extensive system simulator to benchmark expected system performance based on detailed modeling of the network/radio characteristics, CONOPS, and secure distributed file system functionality. The simulator is highly customizable for the purpose of determining expected system performance for other network topologies and CONOPS.

  2. Detecting Malicious Code by Binary File Checking

    Directory of Open Access Journals (Sweden)

    Marius POPA

    2014-01-01

    Full Text Available The object, library and executable code is stored in binary files. Functionality of a binary file is altered when its content or program source code is changed, causing undesired effects. A direct content change is possible when the intruder knows the structural information of the binary file. The paper describes the structural properties of the binary object files, how the content can be controlled by a possible intruder and what the ways to identify malicious code in such kind of files. Because the object files are inputs in linking processes, early detection of the malicious content is crucial to avoid infection of the binary executable files.

  3. Formalizing a hierarchical file system

    NARCIS (Netherlands)

    Hesselink, Wim H.; Lali, Muhammad Ikram

    An abstract file system is defined here as a partial function from (absolute) paths to data. Such a file system determines the set of valid paths. It allows the file system to be read and written at a valid path, and it allows the system to be modified by the Unix operations for creation, removal,

  4. Micro-CT assessment of two different endodontic preparation systems

    Directory of Open Access Journals (Sweden)

    Cacio Moura-Netto

    2013-02-01

    Full Text Available The aim of this study was to compare two endodontic preparation systems using micro-CT analysis. Twenty-four one-rooted mandibular premolars were selected and randomly assigned to two groups. The samples (n = 12 of Group 1 were prepared using the ProTaper Universal rotary system, while Group 2 (n = 12 was prepared using the EndoEZE AET system complemented by manual apical preparation with K-type hand files up to #30. A 2.5% sodium hypochlorite solution was used in both groups for irrigating. Both groups were scanned by high-resolution microcomputed tomography before and after preparation (SkyScan 1172, SkyScan, Kontich, Belgium. The root canal volume and surface area was measured before and after preparation, and the differences were calculated and analyzed for statistically significant differences using ANOVA complemented by the Tukey test (p < 0.05. The results showed no statistically significant differences between the mean volumes of dentin removal by the two systems. However, the EndoEZE AET system presented a significantly greater mean surface area compared to the ProTaper system (p < 0.05. The EndoEZE AET system enabled preparation of a greater root canal surface area when compared to the ProTaper Universal system. There seemed to be no difference in dentin volume loss between the two systems used.

  5. 77 FR 74839 - Combined Notice of Filings

    Science.gov (United States)

    2012-12-18

    ..., LP. Description: National Grid LNG, LP submits tariff filing per 154.203: Adoption of NAESB Version 2... with Order to Amend NAESB Version 2.0 Filing to be effective 12/1/2012. Filed Date: 12/11/12. Accession...: Refile to comply with Order on NAESB Version 2.0 Filing to be effective 12/1/2012. Filed Date: 12/11/12...

  6. Formalizing a Hierarchical File System

    NARCIS (Netherlands)

    Hesselink, Wim H.; Lali, M.I.

    2009-01-01

    In this note, we define an abstract file system as a partial function from (absolute) paths to data. Such a file system determines the set of valid paths. It allows the file system to be read and written at a valid path, and it allows the system to be modified by the Unix operations for removal

  7. 77 FR 28866 - Shelbyville Hydro LLC; Notice of Application Accepted for Filing and Soliciting Motions To...

    Science.gov (United States)

    2012-05-16

    ... feet. The proposed Lake Shelbyville Project would consist of: (1) A trash rack with 4-inch spacing..., recommendations, terms and conditions, or prescriptions. All filings must (1) bear in all capital letters the...

  8. The incidence of root microcracks caused by 3 different single-file systems versus the ProTaper system.

    Science.gov (United States)

    Liu, Rui; Hou, Ben Xiang; Wesselink, Paul R; Wu, Min-Kai; Shemesh, Hagay

    2013-08-01

    The aim of this study was to compare the incidence of root cracks observed at the apical root surface and/or in the canal wall after canal instrumentation with 3 single-file systems and the ProTaper system (Dentsply Maillefer, Ballaigues, Switzerland). One hundred mandibular incisors were selected. Twenty control teeth were coronally flared with Gates-Glidden drills (Dentsply Maillefer). No further preparation was made. The other 80 teeth were mounted in resin blocks with simulated periodontal ligaments, and the apex was exposed. They were divided into 4 experimental groups (n = 20); the root canals were first coronally flared with Gates-Glidden drills and then instrumented to the full working length with the ProTaper, OneShape (Micro-Mega, Besancon, France), Reciproc (VDW, Munich, Germany), or the Self-Adjusting File (ReDent-Nova, Ra'anana, Israel). The apical root surface and horizontal sections 2, 4, and 6 mm from the apex were observed under a microscope. The presence of cracks was noted. The chi-square test was performed to compare the appearance of cracked roots between the experimental groups. No cracks were found in the control teeth and teeth instrumented with the Self-Adjusting File. Cracks were found in 10 of 20 (50%), 7 of 20 (35%), and 1 of 20 (5%) teeth after canal instrumentation with the ProTaper, OneShape, and Reciproc files, respectively. The difference between the experimental groups was statistically significant (P File and Reciproc files caused less cracks than the ProTaper and OneShape files. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  9. 77 FR 35371 - Combined Notice of Filings #1

    Science.gov (United States)

    2012-06-13

    .... Applicants: Duke Energy Miami Fort, LLC. Description: MBR Filing to be effective 10/1/2012. Filed Date: 6/5...-000. Applicants: Duke Energy Piketon, LLC. Description: MBR Filing to be effective 10/1/2012. Filed...-1959-000. Applicants: Duke Energy Stuart, LLC. Description: MBR Filing to be effective 10/1/2012. Filed...

  10. Virtual file system for PSDS

    Science.gov (United States)

    Runnels, Tyson D.

    1993-01-01

    This is a case study. It deals with the use of a 'virtual file system' (VFS) for Boeing's UNIX-based Product Standards Data System (PSDS). One of the objectives of PSDS is to store digital standards documents. The file-storage requirements are that the files must be rapidly accessible, stored for long periods of time - as though they were paper, protected from disaster, and accumulative to about 80 billion characters (80 gigabytes). This volume of data will be approached in the first two years of the project's operation. The approach chosen is to install a hierarchical file migration system using optical disk cartridges. Files are migrated from high-performance media to lower performance optical media based on a least-frequency-used algorithm. The optical media are less expensive per character stored and are removable. Vital statistics about the removable optical disk cartridges are maintained in a database. The assembly of hardware and software acts as a single virtual file system transparent to the PSDS user. The files are copied to 'backup-and-recover' media whose vital statistics are also stored in the database. Seventeen months into operation, PSDS is storing 49 gigabytes. A number of operational and performance problems were overcome. Costs are under control. New and/or alternative uses for the VFS are being considered.

  11. Guidebook for the ENDF/B-V nuclear data files

    International Nuclear Information System (INIS)

    Magurno, B.A.; Kinsey, R.R.; Scheffel, F.M.

    1982-07-01

    The National Nuclear Data Center (NNDC) has provided the Electric Power Research Institute (EPRI) with a convenient reference/guidebook to nuclear data derived from the Evaluated Nuclear Data File, Version V (ENDF/B-V). The main part of the edition consists of plots of the major cross sections for each of the General Purpose Nuclides. These plots are reconstructed from the resonance parameters and background cross sections given in the library. The resolution and display format have been selected to show general trends in the data. Following the section for individual nuclides, an intercomparison of cross section ratios (plots of eta and α values) is provided for the major fissile nuclei. The final section contains a table of nuclide properties derived from the data files. Included are thermal (2200m/sec and maxwellian averaged) cross sections, g factors, infinitely dilute resonance integrals and fission spectrum averages

  12. JENDL special purpose data files and related nuclear data

    International Nuclear Information System (INIS)

    Iijima, Shungo

    1989-01-01

    The objectives of JENDL Special Purpose Data Files under development are the applications of nuclear data to the evaluation of the fuel cycle, nuclear activation, and radiation damage. The files in plan consist of 9 types of data, viz., the actinide cross sections, the decay data, the activation cross sections, the (α,n) cross sections, the photo-reaction cross sections, the dosimetry cross sections, the gas production cross sections, the primary knock-on atom spectra and KERMA factors, and the data for standard. The status of the compilation and the evaluation of these data are briefly reviewed. In particular, the features of the data required for the evaluation of the activation cross sections, (α,n) cross sections, photo-reaction cross sections, and PKA data are discussed in some detail. The need for the realistic definition of the scope of the work is emphasized. (author)

  13. A lightweight high availability strategy for Atlas LCG File Catalogs

    International Nuclear Information System (INIS)

    Martelli, Barbara; Salvo, Alessandro de; Anzellotti, Daniela; Rinaldi, Lorenzo; Cavalli, Alessandro; Pra, Stefano dal; Dell'Agnello, Luca; Gregori, Daniele; Prosperini, Andrea; Ricci, Pier Paolo; Sapunenko, Vladimir

    2010-01-01

    The LCG File Catalog is a key component of the LHC Computing Grid middleware [1], as it contains the mapping between Logical File Names and Physical File Names on the Grid. The Atlas computing model foresees multiple local LFC housed in each Tier-1 and Tier-0, containing all information about files stored in the regional cloud. As the local LFC contents are presently not replicated anywhere, this turns out in a dangerous single point of failure for all of the Atlas regional clouds. In order to solve this problem we propose a novel solution for high availability (HA) of Oracle based Grid services, obtained by composing an Oracle Data Guard deployment and a series of application level scripts. This approach has the advantage of being very easy to deploy and maintain, and represents a good candidate solution for all Tier-2s which are usually little centres with little manpower dedicated to service operations. We also present the results of a wide range of functionality and performance tests run on a test-bed having characteristics similar to the ones required for production. The test-bed consists of a failover deployment between the Italian LHC Tier-1 (INFN - CNAF) and an Atlas Tier-2 located at INFN - Roma1. Moreover, we explain how the proposed strategy can be deployed on the present Grid infrastructure, without requiring any change to the middleware and in a way that is totally transparent to end users and applications.

  14. SU-F-T-233: Evaluation of Treatment Delivery Parameters Using High Resolution ELEKTA Log Files

    Energy Technology Data Exchange (ETDEWEB)

    Kabat, C; Defoor, D; Alexandrian, A; Papanikolaou, N; Stathakis, S [University of Texas HSC SA, San Antonio, TX (United States)

    2016-06-15

    Purpose: As modern linacs have become more technologically advanced with the implementation of IGRT and IMRT with HDMLCs, a requirement for more elaborate tracking techniques to monitor components’ integrity is paramount. ElektaLog files are generated every 40 milliseconds, which can be analyzed to track subtle changes and provide another aspect of quality assurance. This allows for constant monitoring of fraction consistency in addition to machine reliability. With this in mind, it was the aim of the study to evaluate if ElektaLog files can be utilized for linac consistency QA. Methods: ElektaLogs were reviewed for 16 IMRT patient plans with >16 fractions. Logs were analyzed by creating fluence maps from recorded values of MLC locations, jaw locations, and dose per unit time. Fluence maps were then utilized to calculate a 2D gamma index with a 2%–2mm criteria for each fraction. ElektaLogs were also used to analyze positional errors for MLC leaves and jaws, which were used to compute an overall error for the MLC banks, Y-jaws, and X-jaws by taking the root-meansquare value of the individual recorded errors during treatment. Additionally, beam on time was calculated using the number of ElektaLog file entries within the file. Results: The average 2D gamma for all 16 patient plans was found to be 98.0±2.0%. Recorded gamma index values showed an acceptable correlation between fractions. Average RMS values for MLC leaves and the jaws resulted in a leaf variation of roughly 0.3±0.08 mm and jaw variation of about 0.15±0.04 mm, both of which fall within clinical tolerances. Conclusion: The use of ElektaLog files for day-to-day evaluation of linac integrity and patient QA can be utilized to allow for reliable analysis of system accuracy and performance.

  15. SU-F-T-233: Evaluation of Treatment Delivery Parameters Using High Resolution ELEKTA Log Files

    International Nuclear Information System (INIS)

    Kabat, C; Defoor, D; Alexandrian, A; Papanikolaou, N; Stathakis, S

    2016-01-01

    Purpose: As modern linacs have become more technologically advanced with the implementation of IGRT and IMRT with HDMLCs, a requirement for more elaborate tracking techniques to monitor components’ integrity is paramount. ElektaLog files are generated every 40 milliseconds, which can be analyzed to track subtle changes and provide another aspect of quality assurance. This allows for constant monitoring of fraction consistency in addition to machine reliability. With this in mind, it was the aim of the study to evaluate if ElektaLog files can be utilized for linac consistency QA. Methods: ElektaLogs were reviewed for 16 IMRT patient plans with >16 fractions. Logs were analyzed by creating fluence maps from recorded values of MLC locations, jaw locations, and dose per unit time. Fluence maps were then utilized to calculate a 2D gamma index with a 2%–2mm criteria for each fraction. ElektaLogs were also used to analyze positional errors for MLC leaves and jaws, which were used to compute an overall error for the MLC banks, Y-jaws, and X-jaws by taking the root-meansquare value of the individual recorded errors during treatment. Additionally, beam on time was calculated using the number of ElektaLog file entries within the file. Results: The average 2D gamma for all 16 patient plans was found to be 98.0±2.0%. Recorded gamma index values showed an acceptable correlation between fractions. Average RMS values for MLC leaves and the jaws resulted in a leaf variation of roughly 0.3±0.08 mm and jaw variation of about 0.15±0.04 mm, both of which fall within clinical tolerances. Conclusion: The use of ElektaLog files for day-to-day evaluation of linac integrity and patient QA can be utilized to allow for reliable analysis of system accuracy and performance.

  16. SU-F-T-465: Two Years of Radiotherapy Treatments Analyzed Through MLC Log Files

    Energy Technology Data Exchange (ETDEWEB)

    Defoor, D [University of Texas HSC SA, New Braunfles, TX (United States); Kabat, C; Papanikolaou, N [University of Texas HSC SA, San Antonio, TX (United States); Stathakis, S [Cancer Therapy and Research Center, San Antonio, TX (United States)

    2016-06-15

    Purpose: To present treatment statistics of a Varian Novalis Tx using more than 90,000 Varian Dynalog files collected over the past 2 years. Methods: Varian Dynalog files are recorded for every patient treated on our Varian Novalis Tx. The files are collected and analyzed daily to check interfraction agreement of treatment deliveries. This is accomplished by creating fluence maps from the data contained in the Dynalog files. From the Dynalog files we have also compiled statistics for treatment delivery times, MLC errors, gantry errors and collimator errors. Results: The mean treatment time for VMAT patients was 153 ± 86 seconds while the mean treatment time for step & shoot was 256 ± 149 seconds. Patient’s treatment times showed a variation of 0.4% over there treatment course for VMAT and 0.5% for step & shoot. The average field sizes were 40 cm2 and 26 cm2 for VMAT and step & shoot respectively. VMAT beams contained and average overall leaf travel of 34.17 meters and step & shoot beams averaged less than half of that at 15.93 meters. When comparing planned and delivered fluence maps generated using the Dynalog files VMAT plans showed an average gamma passing percentage of 99.85 ± 0.47. Step & shoot plans showed an average gamma passing percentage of 97.04 ± 0.04. 5.3% of beams contained an MLC error greater than 1 mm and 2.4% had an error greater than 2mm. The mean gantry speed for VMAT plans was 1.01 degrees/s with a maximum of 6.5 degrees/s. Conclusion: Varian Dynalog files are useful for monitoring machine performance treatment parameters. The Dynalog files have shown that the performance of the Novalis Tx is consistent over the course of a patients treatment with only slight variations in patient treatment times and a low rate of MLC errors.

  17. 76 FR 63291 - Combined Notice Of Filings #1

    Science.gov (United States)

    2011-10-12

    ... filing per 35: MBR Tariff to be effective 9/23/2011. Filed Date: 09/23/2011. Accession Number: 20110923.... submits tariff filing per 35: MBR Tariff to be effective 9/23/2011. Filed Date: 09/23/2011. Accession.... submits tariff filing per 35: MBR Tariff to be effective 9/23/2011. Filed Date: 09/23/2011. Accession...

  18. Print preparation of the logical INIS-character set for a digital LNO3 printer

    International Nuclear Information System (INIS)

    Mueller, M.; Nevyjel, A.

    1987-09-01

    The implementation of the revised INIS-character set (describedin INIS-Circular Letter No.131) made it necessary to develop a print preparation program, which transfers most of the new INIS logical characters to characters, which are printable on a local LNO3 laser printer. The program is written in PL/I and runs under VAX/VMS on a VAX 11/750. It reads a normal print file and replaces the encoded logical characters by special control sequences, which generate the corresponding images on the LNO3 printer. The program is used for print preparation of any INIS-data records, both input preparation and output tape utilisation on the local VAX system. (Author)

  19. 76 FR 28018 - Combined Notice of Filings #1

    Science.gov (United States)

    2011-05-13

    ... tariff filing per 35.13(a)(2)(iii: Information Policy Revisions to be effective 6/20/ 2011. Filed Date... Interconnection, L.L.C. Description: PJM Interconnection, L.L.C. submits tariff filing per 35.13(a)(2)(iii: Queue... New Mexico submits tariff filing per 35.13(a)(2)(iii: PNM LGIP Filing to be effective 7/5/2011. Filed...

  20. 75 FR 62381 - Combined Notice of Filings #2

    Science.gov (United States)

    2010-10-08

    ... filing per 35.12: MeadWestvaco Virginia MBR Filing to be effective 9/ 28/2010. Filed Date: 09/29/2010... submits tariff filing per 35.12: City Power MBR Tariff to be effective 9/30/2010. Filed Date: 09/29/2010... Baseline MBR Tariff to be effective 9[sol]29[sol]2010. Filed Date: 09/29/2010. Accession Number: 20100929...

  1. Global Navigation Satellite System (GNSS) Final Clock Product (5 minute resolution, daily files, generated weekly) from NASA CDDIS

    Data.gov (United States)

    National Aeronautics and Space Administration — This derived product set consists of Global Navigation Satellite System Final Satellite and Receiver Clock Product (5-minute granularity, daily files, generated...

  2. 77 FR 13587 - Combined Notice of Filings

    Science.gov (United States)

    2012-03-07

    .... Applicants: Transcontinental Gas Pipe Line Company. Description: Annual Electric Power Tracker Filing... Company. Description: 2012 Annual Fuel and Electric Power Reimbursement to be effective 4/1/2012. Filed... submits tariff filing per 154.403: Storm Surcharge 2012 to be effective 4/1/2012. Filed Date: 3/1/12...

  3. 10 CFR 2.302 - Filing of documents.

    Science.gov (United States)

    2010-01-01

    ... this part shall be electronically transmitted through the E-Filing system, unless the Commission or... all methods of filing have been completed. (e) For filings by electronic transmission, the filer must... digital ID certificates, the NRC permits participants in the proceeding to access the E-Filing system to...

  4. 5 CFR 1201.14 - Electronic filing procedures.

    Science.gov (United States)

    2010-01-01

    ... form. (b) Matters subject to electronic filing. Subject to the registration requirement of paragraph (e) of this section, parties and representatives may use electronic filing (e-filing) to do any of the...). (d) Internet is sole venue for electronic filing. Following the instructions at e-Appeal Online, the...

  5. Summary report of the technical meeting on 'International Reactor Dosimetry File: IRDF-2002'

    International Nuclear Information System (INIS)

    Greenwood, L.R.; Paviotti-Corcuera, R.

    2002-09-01

    This report summarizes the presentations, recommendations and conclusions of the Technical Meeting on 'International Reactor Dosimetry File: IRDF-2002.' The purpose of this meeting was to discuss scientific and technical matters related to the subject and coordinate related tasks. Discussions were held and recommendations were given for the preparation of the files on topics related to: reactions to be included, need for new evaluations or revisions, decay data, radiation damage data, integral testing in benchmark fields, and computer codes to be included. Tasks were assigned and deadlines were set. The participants emphasized that accurate and complete knowledge of nuclear data for reactor dosimetry are essential for improving the accuracy of the reactor pressure vessel service life assessment of nuclear power plants as well as in other neutron metrology applications such as boron neutron capture therapy, therapeutic use of medical isotopes, nuclear physics measurements, and reactor safety applications. (author)

  6. Idaho National Engineering Laboratory (INEL) Environmental Restoration Program (ERP), Baseline Safety Analysis File (BSAF). Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    1994-06-20

    This document was prepared to take the place of a Safety Evaluation Report since the Baseline Safety Analysis File (BSAF)and associated Baseline Technical Safety Requirements (TSR) File do not meet the requirements of a complete safety analysis documentation. Its purpose is to present in summary form the background of how the BSAF and Baseline TSR originated and a description of the process by which it was produced and approved for use in the Environmental Restoration Program.The BSAF is a facility safety reference document for INEL environmental restoration activities including environmental remediation of inactive waste sites and decontamination and decommissioning (D&D) of surplus facilities. The BSAF contains safety bases common to environmental restoration activities and guidelines for performing and documenting safety analysis. The common safety bases can be incorporated by reference into the safety analysis documentation prepared for individual environmental restoration activities with justification and any necessary revisions. The safety analysis guidelines in BSAF provide an accepted method for hazard analysis; analysis of normal, abnormal, and accident conditions; human factors analysis; and derivation of TSRS. The BSAF safety bases and guidelines are graded for environmental restoration activities.

  7. Idaho National Engineering Laboratory (INEL) Environmental Restoration Program (ERP), Baseline Safety Analysis File (BSAF). Revision 1

    International Nuclear Information System (INIS)

    1994-01-01

    This document was prepared to take the place of a Safety Evaluation Report since the Baseline Safety Analysis File (BSAF)and associated Baseline Technical Safety Requirements (TSR) File do not meet the requirements of a complete safety analysis documentation. Its purpose is to present in summary form the background of how the BSAF and Baseline TSR originated and a description of the process by which it was produced and approved for use in the Environmental Restoration Program.The BSAF is a facility safety reference document for INEL environmental restoration activities including environmental remediation of inactive waste sites and decontamination and decommissioning (D ampersand D) of surplus facilities. The BSAF contains safety bases common to environmental restoration activities and guidelines for performing and documenting safety analysis. The common safety bases can be incorporated by reference into the safety analysis documentation prepared for individual environmental restoration activities with justification and any necessary revisions. The safety analysis guidelines in BSAF provide an accepted method for hazard analysis; analysis of normal, abnormal, and accident conditions; human factors analysis; and derivation of TSRS. The BSAF safety bases and guidelines are graded for environmental restoration activities

  8. Effects of Glide Path on the Centering Ability and Preparation Time of Two Reciprocating Instruments

    Science.gov (United States)

    Coelho, Marcelo Santos; Fontana, Carlos Eduardo; Kato, Augusto Shoji; de Martin, Alexandre Sigrist; da Silveira Bueno, Carlos Eduardo

    2016-01-01

    Introduction: The aim of this in vitro study was to evaluate the effects of establishing glide path on the centering ability and preparation time of two single-file reciprocating systems in mesial root canals of mandibular molars. Methods and Materials: Sixty extracted mandibular molars with curvatures of 25-39 degrees and separate foramina for the mesiobuccal and mesiolingual canals, were divided into four groups (n=15); WaveOne+glide path; WaveOne; Reciproc+glide path and Reciproc. Non-patent canals were excluded and only one canal in each tooth was instrumented. A manual glide path was established in first and third groups with #10, 15 and 20 hand K-files. Preparation was performed with reciprocating in-and-out motion, with a 3-4 mm amplitude and slight apical pressure. Initial and final radiographs were taken to analyze the amount of dentin removed in the instrumented canals. The radiographs were superimposed with an image editing software and examined to assess discrepancies at 3-, 6- and 9-mm distances from the apex. The Kruskal-Wallis test was used for statistical analysis. The level of significance was set at 0.05. Results: Preparation in groups without glide paths was swifter than the other groups (P=0.001). However, no difference was observed regarding centering ability. Conclusion: Establishing a glide path increased the total instrumentation time for preparing curved canals with WaveOne and Reciproc instruments. Glide path had no influence on the centering ability of these systems. PMID:26843875

  9. The File System Interface is an Anachronism

    OpenAIRE

    Ellard, Daniel

    2003-01-01

    Contemporary file systems implement a set of abstractions and semantics that are suboptimal for many (if not most) purposes. The philosophy of using the simple mechanisms of the file system as the basis for a vast array of higher-level mechanisms leads to inefficient and incorrect implementations. We propose several extensions to the canonical file system model, including explicit support for lock files, indexed files, and resource forks, and the benefit of session semantics for write updates...

  10. CT evaluation of canal preparation using rotary and hand NI-TI instruments: An in vitro study.

    Science.gov (United States)

    Nagaraja, Shruthi; Sreenivasa Murthy, B V

    2010-01-01

    Controlled, uniformly tapered radicular preparation is a great challenge in endodontics. Improper preparation can lead to procedural errors like transportation of foramen, uneven dentine thickness, stripping of root canal, formation of ledge, zip, and elbow in curved canals. These procedural errors and their sequel can adversely affect the prognosis of treatment. The present in vitro study aims to evaluate canal preparation based on the following factors: canal transportation, remaining dentine thickness and comparing centering ability between hand Ni-Ti K files and ProTaper rotary Ni-Ti instruments using computed tomography (CT). For evaluation, 30 mesiobuccal roots of maxillary molars were selected. Of these, 15 roots were distributed into two groups where Group 1 included hand instrumentation with Ni-Ti K-files; and Group 2 comprised ProTaper NiTi rotary system. Pre instrumentation and post instrumentation three-dimensional CT images were obtained from root cross-sections that were 1 mm thick from apex to the canal orifice; scanned images were then superimposed and compared. It was observed that the manual technique using hand Ni-Ti K-file produced lesser canal transportation and maintained greater dentine thickness than the rotary ProTaper technique at middle and coronal third and this difference was statistically significant. No significant difference was seen with regard to canal transportation and remaining root dentine at apical levels. With regard to centering ratio, no significant difference was seen between both the groups at all levels. ProTaper should be used judiciously, especially in curved canals, as it causes higher canal transportation and thinning of root dentine at middle and coronal levels. None of the groups showed optimal centering ability.

  11. Consistent Data Assimilation of Actinide Isotopes: 235U and 239Pu

    International Nuclear Information System (INIS)

    Palmiottti, G.; Hiruta, H.; Salvatores, M.

    2011-01-01

    In this annual report we illustrate the methodology of the consistent data assimilation that allows to use the information coming from integral experiments for improving the basic nuclear parameters used in cross section evaluation. A series of integral experiments were analyzed using the EMPIRE evaluated files for 235 U, 238 U, and 239 Pu. Inmost cases the results have shown quite large worse results with respect to the corresponding existing evaluations available for ENDF/B-VII. The observed discrepancies between calculated and experimental results were used in conjunction with the computed sensitivity coefficients and covariance matrix for nuclear parameters in a consistent data assimilation. Only the GODIVA and JEZEBEL experimental results were used, in order to exploit information relative to the isotope of interest that are, in this particular case: 235 U and 239 Pu. The results obtained by the consistent data assimilation indicate that with reasonable modifications (mostly within the initial standard deviation) it is possible to eliminate the original large discrepancies on the K eff of the two critical configurations. However, some residual discrepancy remains for a few fission spectral indices that are, most likely, to be attributed to the detector cross sections.

  12. Pengaruh Efektifitas Penyusunan Dan Penggunaan Daftar Wajib Pajak (Master File , Struktur Organisasi Dan Prosedur Perpajakan Dalam Administrasi Perpajakan Terhadap Penerimaan Pajak Di Kantor Wilayah Direktorat Jendral Pajak Jakarta I

    Directory of Open Access Journals (Sweden)

    Hanifah Hanifah

    2011-04-01

    Full Text Available                            Tax is one source of revenue that is essential for the administration and development. Tax revenues are used to finance the construction of which is useful for the common good. The government's commitment to not rely on foreign debt and oil revenues make tax revenue as the backbone of the government to finance its activities. The government's efforts to increase tax revenue is one done through reform of the tax system, particularly the modern tax administration. But this has not succeeded optimally, is seen where tax revenues are still far from the expected tax potential. So that no indication is still not optimal level of effectiveness of the preparation and use of a list of taxpayers (master file, organizational structure and taxation procedures performed in DJP Jakarta I. Thus the purpose of this study was to determine whether the effectiveness of the preparation and use of a list of taxpayers (master files, organizational structure and procedures of taxation effect on tax revenue either partially or simultaneously.               Based on the results of the study showed that the effectiveness of the preparation and use of a list of taxpayers (master file, organizational structure and procedures of taxation can be said to have been effective, but not optimal so that needs to be improved further. Then based on test results that the preparation and use of a list of taxpayers (master file, organizational structure and procedures of taxation influence simultaneously to tax revenues amounted to 79.77% and 20.23% influenced by other factors. Partially, each influential of 35.67%, 26.35% and 17.75%. Keywords: preparation and use of taxpayer list; structural organization; procedures                taxation in modern tax administration

  13. High School and Beyond: Twins and Siblings' File Users' Manual, User's Manual for Teacher Comment File, Friends File Users' Manual.

    Science.gov (United States)

    National Center for Education Statistics (ED), Washington, DC.

    These three users' manuals are for specific files of the High School and Beyond Study, a national longitudinal study of high school sophomores and seniors in 1980. The three files are computerized databases that are available on magnetic tape. As one component of base year data collection, information identifying twins, triplets, and some non-twin…

  14. Menggabungkan Beberapa File Dalam SPSS/PC

    Directory of Open Access Journals (Sweden)

    Syahrudji Naseh

    2012-09-01

    Full Text Available Pada dasamya piranti lunak komputer dapat dibagi ke dalam lima kelompok besar yaitu pengolah kata, spreadsheet database, statistika dan animasi/desktop. Masing-masing mempunyai kelebihan dan kekurangannya. Piranti lunak dBase 111+ yang merupakan piranti lunak paling populer dalam"database", hanya dapat menampung 128 variabel saja. Oleh karenanya pada suatu kuesioner yang besar seperti Susenas (Survei Sosial Ekonomi Nasional atau SKRT (Survei Kesehatan Rumah Tangga, datanya tidak dapat dijadikan satu "file". Biasanya dipecah menjadi banyak "file", umpamanya fileldbf, file2.dbf dan seterusnya.Masalahnya adalah bagaimana menggabung beberapa variabel yang ada di file1.dbf engan beberapa variabel yang ada di file5.dbf? Tulisan ini mencoba membahas masalah tersebut

  15. 76 FR 70651 - Fee for Filing a Patent Application Other Than by the Electronic Filing System

    Science.gov (United States)

    2011-11-15

    ... government; or (3) preempt tribal law. Therefore, a tribal summary impact statement is not required under... 0651-AC64 Fee for Filing a Patent Application Other Than by the Electronic Filing System AGENCY: United..., that is not filed by electronic means as prescribed by the Director of the United States Patent and...

  16. Quantitative evaluation of apical extrusion of intracanal bacteria using rotary ProTaper, K3XF, twisted and hand K-file system: An ex vivo study.

    Science.gov (United States)

    Ghogre, Priyanka; Chourasia, Hemant Ramesh; Agarwal, Manish; Singh, M P; Gurav, Sandeep; Ghogre, Rahul

    2015-01-01

    The aim of this study was to evaluate the number of intracanal bacteria extruded apically during root canal preparation using rotary ProTaper, K3XF, twisted, and hand K-file system. Seventy extracted single-rooted human mandibular premolar teeth were used. Access cavities were prepared and the teeth were mounted in glass vials. Root canals were then contaminated with a pure culture of Enterococcus faecalis (ATCC 29212) and incubated at 37°C for 24 h. The contaminated roots were divided into four experimental groups of 15 teeth each and one control group of 10 teeth. Group 1: ProTaper; Group 2: K3XF; Group 3: Twisted file; Group 4: Hand K-file; Group 5: Control group. Bacteria extruded from the apical foramen during instrumentation were collected into vials. The microbiological samples were incubated in culture media for 24 h. Colonies of bacteria were counted and the results were given as number of colony-forming units (CFU)/ml. The obtained data were analyzed using the Kruskal-Wallis one-way analysis of variance and Mann-Whitney U-tests. There was a significant difference between the rotary and hand instrumentation system related to the apically extruded intracanal bacteria. Both the rotary and hand instrumentation systems extruded intracanal bacteria through the apical foramen. K3XF file system showed least bacterial extrusion amongst all instrumentation groups.

  17. Technological advances in endodontics: treatment of a mandibular molar with internal root resorption using a reciprocating single-file system.

    Science.gov (United States)

    de Souza, Samir Noronha; Marques, André Augusto Franco; Sponchiado-Júnior, EmÍlio Carlos; Roberti Garcia, Lucas da Fonseca; da Frota, Matheus Franco; de Carvalho, Fredson Márcio Acris

    2017-01-01

    The field of endodontics has become increasingly successful due to technological advances that allow clinicians to solve clinical cases that would have been problematic a few years ago. Despite such advances, endodontic treatment of teeth with internal root resorption remains challenging. This article presents a clinical case in which a reciprocating single-file system was used for endodontic treatment of a mandibular molar with internal root resorption. Radiographic examination revealed the presence of internal root resorption in the distobuccal root canal of the mandibular right first molar. A reciprocating single-file system was used for root canal instrumentation and final preparation, and filling was obtained through a thermal compaction technique. No painful symptoms or periapical lesions were observed in 12 months of follow-up. The results indicate that a reciprocating single-file system is an adequate alternative for root canal instrumentation, particularly in teeth with internal root resorption.

  18. Thin composite films consisting of polypyrrole and polyparaphenylene

    International Nuclear Information System (INIS)

    Golovtsov, I.; Bereznev, S.; Traksmaa, R.; Opik, A.

    2007-01-01

    This study demonstrates that the combined method for the formation of thin composite films, consisting of polypyrrole (PPy) as a film forming agent and polyparaphenylene (PPP) with controlled electrical properties and high stability, enables one to avoid the low processability of PPP and to extend the possibilities for the development of electronic devices. The high temperature (250-600 deg. C) doping method was used for PPP preparation. The crystallinity and grindability of PPP was found to be increasing with the thermochemical modification. Thin composite films were prepared onto the light transparent substrates using the simple electropolymerization technique. The properties of films were characterized by the optical transmittance and temperature-dependent conductivity measurements. The morphology and thickness of the prepared films were determined using the scanning electron microscopy. The composite films showed a better adhesion to an inorganic substrate. It was found to be connected mostly with the improved properties of the high temperature doped PPP. The current-voltage characteristics of indium tin oxide/film/Au hybrid organic-inorganic structures showed the influence of the doping conditions of PPP inclusions in the obtained films

  19. Earnings Public-Use File, 2006

    Data.gov (United States)

    Social Security Administration — Social Security Administration released Earnings Public-Use File (EPUF) for 2006. File contains earnings information for individuals drawn from a systematic random...

  20. 12 CFR 509.10 - Filing of papers.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Filing of papers. 509.10 Section 509.10 Banks... IN ADJUDICATORY PROCEEDINGS Uniform Rules of Practice and Procedure § 509.10 Filing of papers. (a) Filing. Any papers required to be filed, excluding documents produced in response to a discovery request...

  1. A self-consistent model for polycrystal deformation. Description and implementation

    International Nuclear Information System (INIS)

    Clausen, B.; Lorentzen, T.

    1997-04-01

    This report is a manual for the ANSI C implementation of an incremental elastic-plastic rate-insensitive self-consistent polycrystal deformation model based on (Hutchinson 1970). The model is furthermore described in the Ph.D. thesis by Clausen (Clausen 1997). The structure of the main program, sc m odel.c, and its subroutines are described with flow-charts. Likewise the pre-processor, sc i ni.c, is described with a flowchart. Default values of all the input parameters are given in the pre-processor, but the user is able to select from other pre-defined values or enter new values. A sample calculation is made and the results are presented as plots and examples of the output files are shown. (au) 4 tabs., 28 ills., 17 refs

  2. 47 CFR 61.14 - Method of filing publications.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Method of filing publications. 61.14 Section 61...) TARIFFS Rules for Electronic Filing § 61.14 Method of filing publications. (a) Publications filed... date of a publication received by the Electronic Tariff Filing System will be determined by the date...

  3. Structural Consistency, Consistency, and Sequential Rationality.

    OpenAIRE

    Kreps, David M; Ramey, Garey

    1987-01-01

    Sequential equilibria comprise consistent beliefs and a sequentially ra tional strategy profile. Consistent beliefs are limits of Bayes ratio nal beliefs for sequences of strategies that approach the equilibrium strategy. Beliefs are structurally consistent if they are rationaliz ed by some single conjecture concerning opponents' strategies. Consis tent beliefs are not necessarily structurally consistent, notwithstan ding a claim by Kreps and Robert Wilson (1982). Moreover, the spirit of stru...

  4. 12 CFR 263.10 - Filing of papers.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 3 2010-01-01 2010-01-01 false Filing of papers. 263.10 Section 263.10 Banks... OF PRACTICE FOR HEARINGS Uniform Rules of Practice and Procedure § 263.10 Filing of papers. (a) Filing. Any papers required to be filed, excluding documents produced in response to a discovery request...

  5. 12 CFR 308.10 - Filing of papers.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Filing of papers. 308.10 Section 308.10 Banks... AND PROCEDURE Uniform Rules of Practice and Procedure § 308.10 Filing of papers. (a) Filing. Any papers required to be filed, excluding documents produced in response to a discovery request pursuant to...

  6. 29 CFR 1981.103 - Filing of discrimination complaint.

    Science.gov (United States)

    2010-07-01

    ... constitute the violations. (c) Place of filing. The complaint should be filed with the OSHA Area Director... or she has been discriminated against by an employer in violation of the Act may file, or have filed..., but may be filed with any OSHA officer or employee. Addresses and telephone numbers for these...

  7. 77 FR 66458 - Combined Notice of Filings #1

    Science.gov (United States)

    2012-11-05

    ... Service Company of Colorado. Description: 2012--10--26 PSCo MBR Filing to be effective 12/26/ 2012. Filed...--SPS MBR Filing to be effective 12/26/2012. Filed Date: 10/26/12. Accession Number: 20121026-5123...: Revised Application for MBR Authorization to be effective 10/16/2012. Filed Date: 10/25/12. Accession...

  8. 75 FR 66075 - Combined Notice of Filings #1

    Science.gov (United States)

    2010-10-27

    ....12: Baseline MBR Concurrence to be effective 10/8/2010. Filed Date: 10/19/2010. Accession Number... Company submits tariff filing per 35.12: Baseline MBR Concurrence to be effective 10/8/2010. Filed Date... Power Company submits tariff filing per 35.12: Baseline MBR Concurrence to be effective 10/8/2010. Filed...

  9. 12 CFR 19.10 - Filing of papers.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 1 2010-01-01 2010-01-01 false Filing of papers. 19.10 Section 19.10 Banks and... Rules of Practice and Procedure § 19.10 Filing of papers. (a) Filing. Any papers required to be filed...) Delivering the papers to a reliable commercial courier service, overnight delivery service, or to the U.S...

  10. 12 CFR 747.10 - Filing of papers.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Filing of papers. 747.10 Section 747.10 Banks... Practice and Procedure § 747.10 Filing of papers. (a) Filing. Any papers required to be filed, excluding...) Delivering the papers to a reliable commercial courier service, overnight delivery service, or to the U.S...

  11. Neutron metrology file NMF-90. An integrated database for performing neutron spectrum adjustment calculations

    International Nuclear Information System (INIS)

    Kocherov, N.P.

    1996-01-01

    The Neutron Metrology File NMF-90 is an integrated database for performing neutron spectrum adjustment (unfolding) calculations. It contains 4 different adjustment codes, the dosimetry reaction cross-section library IRDF-90/NMF-G with covariances files, 6 input data sets for reactor benchmark neutron fields and a number of utility codes for processing and plotting the input and output data. The package consists of 9 PC HD diskettes and manuals for the codes. It is distributed by the Nuclear Data Section of the IAEA on request free of charge. About 10 MB of diskspace is needed to install and run a typical reactor neutron dosimetry unfolding problem. (author). 8 refs

  12. The Effect of Volume of Transaction On The Intention Towards Tax E-filing

    OpenAIRE

    Aziz Saliza Abdul; Idris Kamil Md

    2017-01-01

    Volume of transaction is specifically referring to number of clients or return forms dealing by tax agents/preparers. This variable does play role even though there is less empirical evidence on this matter. This paper is basically to explore the effect of volume of transaction that could possibly influence the acceptance of tax e-filing system as it did in other areas of transaction i.e. court cases. Undoubtedly, it is proved to be significantly influenced the behavioural intention towards t...

  13. Mixed-Media File Systems

    NARCIS (Netherlands)

    Bosch, H.G.P.

    1999-01-01

    This thesis addresses the problem of implementing mixed-media storage systems. In this work a mixed-media file system is defined to be a system that stores both conventional (best-effort) file data and real-time continuous-media data. Continuous-media data is usually bulky, and servers storing and

  14. A user-friendly robotic sample preparation program for fully automated biological sample pipetting and dilution to benefit the regulated bioanalysis.

    Science.gov (United States)

    Jiang, Hao; Ouyang, Zheng; Zeng, Jianing; Yuan, Long; Zheng, Naiyu; Jemal, Mohammed; Arnold, Mark E

    2012-06-01

    Biological sample dilution is a rate-limiting step in bioanalytical sample preparation when the concentrations of samples are beyond standard curve ranges, especially when multiple dilution factors are needed in an analytical run. We have developed and validated a Microsoft Excel-based robotic sample preparation program (RSPP) that automatically transforms Watson worklist sample information (identification, sequence and dilution factor) to comma-separated value (CSV) files. The Freedom EVO liquid handler software imports and transforms the CSV files to executable worklists (.gwl files), allowing the robot to perform sample dilutions at variable dilution factors. The dynamic dilution range is 1- to 1000-fold and divided into three dilution steps: 1- to 10-, 11- to 100-, and 101- to 1000-fold. The whole process, including pipetting samples, diluting samples, and adding internal standard(s), is accomplished within 1 h for two racks of samples (96 samples/rack). This platform also supports online sample extraction (liquid-liquid extraction, solid-phase extraction, protein precipitation, etc.) using 96 multichannel arms. This fully automated and validated sample dilution and preparation process has been applied to several drug development programs. The results demonstrate that application of the RSPP for fully automated sample processing is efficient and rugged. The RSPP not only saved more than 50% of the time in sample pipetting and dilution but also reduced human errors. The generated bioanalytical data are accurate and precise; therefore, this application can be used in regulated bioanalysis.

  15. 76 FR 58257 - Combined Notice of Filings #2

    Science.gov (United States)

    2011-09-20

    ... Hills Wind Farm, LLC MBR Tariff to be effective 10/31/2007. Filed Date: 09/12/2011. Accession Number... filing per 35.1: Smoky Hills Wind Project II, LLC MBR Tariff to be effective 10/20/2008. Filed Date: 09..., LLC submits tariff filing per 35.1: Enel Stillwater, LLC MBR Tariff to be effective 12/5/2008. Filed...

  16. 77 FR 28592 - Combined Notice of Filings #1

    Science.gov (United States)

    2012-05-15

    ...: Middletown MBR Application to be effective 5/8/2012. Filed Date: 5/7/12. Accession Number: 20120507-5128..., LLC. Description: Southern Energy Initial MBR Filing to be effective 5/ 7/2012. Filed Date: 5/8/12... Company submits tariff filing per 35.37: MBR Triennial Filing--1st Rev MBR to be effective 9/30/2010...

  17. 76 FR 59676 - Combined Notice of Filings #1

    Science.gov (United States)

    2011-09-27

    ... MBR Tariff to be effective 10/1/2011. Filed Date: 09/16/2011. Accession Number: 20110916-5146. Comment... 35.1: ONEOK Energy Services Company Baseline MBR Filing to be effective 9/16/2011. Filed Date: 09/16... Services Order No. 697 Compliance Filing of MBR Tariff to be effective 9/16/2011. Filed Date: 09/16/2011...

  18. K-file vs ProFiles in cleaning capacity and instrumentation time in primary molar root canals: An in vitro study

    Directory of Open Access Journals (Sweden)

    N Madan

    2011-01-01

    Full Text Available Objectives: This study compares the efficiency of manual K-files and rotary ProFiles in cleaning capacity and instrumentation time in primary molar root canals. Materials and Methods: Seventy-five maxillary and mandibular primary molar root canals were instrumented with ProFiles and K-files in the step-back manner from size #10 to #40. The teeth were decalcified, dehydrated and cleared, and analyzed for the presence of dye remaining on the root canal walls, which served as an evidence of cleaning capacity of both the techniques. Results: The results showed a significant difference in the cleaning capacity of the root canals with ProFiles and K-files, in apical and coronal thirds of the root canal. ProFiles have been found to be more efficient in cleaning the coronal thirds and K-files in cleaning apical thirds of the root canals. Both the techniques were almost equally effective in cleaning the middle thirds of the canals. The time taken during the cleaning of the root canals appeared to be statistically shorter with K-files than profiles.

  19. 76 FR 40905 - Turnagain Arm Tidal Electric Energy Project; Notice of Intent To File License Application, Filing...

    Science.gov (United States)

    2011-07-12

    ... Tidal Electric Energy Project; Notice of Intent To File License Application, Filing of Pre-Application....: 13509-001. c. Dated Filed: May 11, 2011. d. Submitted By: Turnagain Arm Tidal Energy Corporation. e. Name of Project: Turnagain Arm Tidal Electric Energy Project. f. Location: Of the Upper Cook Inlet off...

  20. 77 FR 58370 - Pennamaquan Tidal Power LLC; Notice of Intent To File License Application, Filing of Pre...

    Science.gov (United States)

    2012-09-20

    ... Tidal Power LLC; Notice of Intent To File License Application, Filing of Pre-Application Document (PAD... Filed: July 19, 2012. d. Submitted By: Pennamaquan Tidal Power LLC (Pennamaquan Power). e. Name of Project: Pennamaquan Tidal Power Plant Project. f. Location: On the Pennamaquan River at the entrance to...

  1. 75 FR 61474 - Juneau Hydropower, Inc.; Notice of Intent To File License Application, Filing of Pre-Application...

    Science.gov (United States)

    2010-10-05

    ... Hydropower, Inc.; Notice of Intent To File License Application, Filing of Pre-Application Document, and....: 13563-001. c. Dated Filed: July 28, 2010. d. Submitted By: Juneau Hydropower, Inc. e. Name of Project... Commission's regulations. h. Potential Applicant Contact: Duff W. Mitchell, Juneau Hydropower, Inc., P.O. Box...

  2. A word processor optimized for preparing journal articles and student papers.

    Science.gov (United States)

    Wolach, A H; McHale, M A

    2001-11-01

    A new Windows-based word processor for preparing journal articles and student papers is described. In addition to standard features found in word processors, the present word processor provides specific help in preparing manuscripts. Clicking on "Reference Help (APA Form)" in the "File" menu provides a detailed help system for entering the references in a journal article. Clicking on "Examples and Explanations of APA Form" provides a help system with examples of the various sections of a review article, journal article that has one experiment, or journal article that has two or more experiments. The word processor can automatically place the manuscript page header and page number at the top of each page using the form required by APA and Psychonomic Society journals. The "APA Form" submenu of the "Help" menu provides detailed information about how the word processor is optimized for preparing articles and papers.

  3. Data_files_Reyes_EHP_phthalates

    Data.gov (United States)

    U.S. Environmental Protection Agency — The file contains three files in comma separated values (.csv) format. “Reyes_EHP_Phthalates_US_metabolites.csv” contains information about the National Health and...

  4. Data management in large-scale collaborative toxicity studies: how to file experimental data for automated statistical analysis.

    Science.gov (United States)

    Stanzel, Sven; Weimer, Marc; Kopp-Schneider, Annette

    2013-06-01

    High-throughput screening approaches are carried out for the toxicity assessment of a large number of chemical compounds. In such large-scale in vitro toxicity studies several hundred or thousand concentration-response experiments are conducted. The automated evaluation of concentration-response data using statistical analysis scripts saves time and yields more consistent results in comparison to data analysis performed by the use of menu-driven statistical software. Automated statistical analysis requires that concentration-response data are available in a standardised data format across all compounds. To obtain consistent data formats, a standardised data management workflow must be established, including guidelines for data storage, data handling and data extraction. In this paper two procedures for data management within large-scale toxicological projects are proposed. Both procedures are based on Microsoft Excel files as the researcher's primary data format and use a computer programme to automate the handling of data files. The first procedure assumes that data collection has not yet started whereas the second procedure can be used when data files already exist. Successful implementation of the two approaches into the European project ACuteTox is illustrated. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. 78 FR 14784 - Northern Natural Gas Company; Notice of Intent To Prepare an Environmental Assessment for the...

    Science.gov (United States)

    2013-03-07

    ... enclosures; aboveground transfer piping including, pipe, and concrete and steel pipe support; isolation... important environmental issues. By this notice, the Commission requests public comments on the scope of the issues to address in the EA. We will consider all filed comments during the preparation of the EA. \\2...

  6. 78 FR 54884 - Antrim County; Notice of Intent To Prepare an Environmental Assessment and Notice of Scoping...

    Science.gov (United States)

    2013-09-06

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 3030-019] Antrim County; Notice of Intent To Prepare an Environmental Assessment and Notice of Scoping Meeting and Environmental Site Review and Soliciting Scoping Comments Take notice that the following hydroelectric application has been filed with the Commission and is...

  7. The image database management system of teaching file using personal computer

    International Nuclear Information System (INIS)

    Shin, M. J.; Kim, G. W.; Chun, T. J.; Ahn, W. H.; Baik, S. K.; Choi, H. Y.; Kim, B. G.

    1995-01-01

    For the systemic management and easy using of teaching file in radiology department, the authors tried to do the setup of a database management system of teaching file using personal computer. We used a personal computer (IBM PC compatible, 486DX2) including a image capture card(Window vision, Dooin Elect, Seoul, Korea) and video camera recorder (8mm, CCD-TR105, Sony, Tokyo, Japan) for the acquisition and storage of images. We developed the database program by using Foxpro for Window 2.6(Microsoft, Seattle, USA) executed in the Window 3.1 (Microsoft, Seattle, USA). Each datum consisted of hospital number, name, sex, age, examination date, keyword, radiologic examination modalities, final diagnosis, radiologic findings, references and representative images. The images were acquired and stored as bitmap format (8 bitmap, 540 X 390 ∼ 545 X 414, 256 gray scale) and displayed on the 17 inch-flat monitor(1024 X 768, Samtron, Seoul, Korea). Without special devices, the images acquisition and storage could be done on the reading viewbox, simply. The image quality on the computer's monitor was less than the one of original film on the viewbox, but generally the characteristics of each lesions could be differentiated. Easy retrieval of data was possible for the purpose of teaching file system. Without high cost appliances, we could consummate the image database system of teaching file using personal computer with relatively inexpensive method

  8. 75 FR 51994 - Combined Notice of Filings

    Science.gov (United States)

    2010-08-24

    ...: Panther Interstate Pipeline Energy, LLC. Description: Panther Interstate Pipeline Energy, LLC submits tariff filing per 154.203: Panther Baseline eTariff Filing to be effective 8/ 12/2010. Filed Date: 08/13...

  9. 75 FR 49923 - Combined Notice of Filings #1

    Science.gov (United States)

    2010-08-16

    ... filing per 35.12: KCP&L-GMO Baseline Filing (Market-Based Volume 28) to be effective 8/2/2010. Filed Date...: KCP&L Greater Missouri Operations Company submits tariff filing per 35.12: GMO Volume 33 (Cost-Based...

  10. A consistent response spectrum analysis including the resonance range

    International Nuclear Information System (INIS)

    Schmitz, D.; Simmchen, A.

    1983-01-01

    The report provides a complete consistent Response Spectrum Analysis for any component. The effect of supports with different excitation is taken into consideration, at is the description of the resonance ranges. It includes information explaining how the contributions of the eigenforms with higher eigenfrequencies are to be considered. Stocking of floor response spectra is also possible using the method described here. However, modified floor response spectra must now be calculated for each building mode. Once these have been prepared, the calculation of the dynamic component values is practically no more complicated than with the conventional, non-consistent methods. The consistent Response Spectrum Analysis can supply smaller and larger values than the conventional theory, a fact which can be demonstrated using simple examples. The report contains a consistent Response Spectrum Analysis (RSA), which, as far as we know, has been formulated in this way for the first time. A consistent RSA is so important because today this method is preferentially applied as an important tool for the earthquake proof of components in nuclear power plants. (orig./HP)

  11. Radiology Teaching Files on the Internet

    International Nuclear Information System (INIS)

    Lim, Eun Chung; Kim, Eun Kyung

    1996-01-01

    There is increasing attention about radiology teaching files on the Internet in the field of diagnostic radiology. The purpose of this study was to aid in the creation of new radiology teaching file by analysing the present radiology teaching file sites on the Internet with many aspects and evaluating images on those sites, using Macintosh II ci compute r, 28.8kbps TelePort Fax/Modem, Netscape Navigator 2.0 software. The results were as follow : 1. Analysis of radiology teaching file sites (1) Country distribution was the highest in USA (57.5%). (2) Average number of cases was 186 cases and radiology teaching file sites with search engine were 9 sites (22.5%). (3) At the method of case arrangement, anatomic area type and diagnosis type were found at the 10 sites (25%) each, question and answer type was found at the 9 sites (22.5%). (4) Radiology teaching file sites with oro-maxillofacial disorder were 9 sites (22.5%). (5) At the image format, GIF format was found at the 14 sites (35%), and JPEG format found at the 14 sites (35%). (6) Created year was the highest in 1995 (43.7%). (7) Continuing case upload was found at the 35 sites (87.5%). 2. Evaluation of images on the radiology teaching files (1) Average file size of GIF format (71 Kbyte) was greater than that of JPEG format (24 Kbyte). (P<0.001) (2) Image quality of GIF format was better than that of JPEG format. (P<0.001)

  12. Detection Of Alterations In Audio Files Using Spectrograph Analysis

    Directory of Open Access Journals (Sweden)

    Anandha Krishnan G

    2015-08-01

    Full Text Available The corresponding study was carried out to detect changes in audio file using spectrograph. An audio file format is a file format for storing digital audio data on a computer system. A sound spectrograph is a laboratory instrument that displays a graphical representation of the strengths of the various component frequencies of a sound as time passes. The objectives of the study were to find the changes in spectrograph of audio after altering them to compare altering changes with spectrograph of original files and to check for similarity and difference in mp3 and wav. Five different alterations were carried out on each audio file to analyze the differences between the original and the altered file. For altering the audio file MP3 or WAV by cutcopy the file was opened in Audacity. A different audio was then pasted to the audio file. This new file was analyzed to view the differences. By adjusting the necessary parameters the noise was reduced. The differences between the new file and the original file were analyzed. By adjusting the parameters from the dialog box the necessary changes were made. The edited audio file was opened in the software named spek where after analyzing a graph is obtained of that particular file which is saved for further analysis. The original audio graph received was combined with the edited audio file graph to see the alterations.

  13. Ground-Based Global Navigation Satellite System (GNSS) Compact Observation Data (1-second sampling, sub-hourly files) from NASA CDDIS

    Data.gov (United States)

    National Aeronautics and Space Administration — This dataset consists of ground-based Global Navigation Satellite System (GNSS) Observation Data (1-second sampling, sub-hourly files) from the NASA Crustal Dynamics...

  14. CT evaluation of canal preparation using rotary and hand NI-TI instruments: An in vitro study

    Science.gov (United States)

    Nagaraja, Shruthi; Sreenivasa Murthy, B V

    2010-01-01

    Background: Controlled, uniformly tapered radicular preparation is a great challenge in endodontics. Improper preparation can lead to procedural errors like transportation of foramen, uneven dentine thickness, stripping of root canal, formation of ledge, zip, and elbow in curved canals. These procedural errors and their sequel can adversely affect the prognosis of treatment. Aim/Objectives: The present in vitro study aims to evaluate canal preparation based on the following factors: canal transportation, remaining dentine thickness and comparing centering ability between hand Ni-Ti K files and ProTaper rotary Ni-Ti instruments using computed tomography (CT). Materials and Methods: For evaluation, 30 mesiobuccal roots of maxillary molars were selected. Of these, 15 roots were distributed into two groups where Group 1 included hand instrumentation with Ni-Ti K-files; and Group 2 comprised ProTaper NiTi rotary system. Pre instrumentation and post instrumentation three-dimensional CT images were obtained from root cross-sections that were 1 mm thick from apex to the canal orifice; scanned images were then superimposed and compared. Result: It was observed that the manual technique using hand Ni-Ti K-file produced lesser canal transportation and maintained greater dentine thickness than the rotary ProTaper technique at middle and coronal third and this difference was statistically significant. No significant difference was seen with regard to canal transportation and remaining root dentine at apical levels. With regard to centering ratio, no significant difference was seen between both the groups at all levels. Conclusion: ProTaper should be used judiciously, especially in curved canals, as it causes higher canal transportation and thinning of root dentine at middle and coronal levels. None of the groups showed optimal centering ability. PMID:20582214

  15. Communication Games Reveal Preparation Contextuality

    Science.gov (United States)

    Hameedi, Alley; Tavakoli, Armin; Marques, Breno; Bourennane, Mohamed

    2017-12-01

    A communication game consists of distributed parties attempting to jointly complete a task with restricted communication. Such games are useful tools for studying limitations of physical theories. A theory exhibits preparation contextuality whenever its predictions cannot be explained by a preparation noncontextual model. Here, we show that communication games performed in operational theories reveal the preparation contextuality of that theory. For statistics obtained in a particular family of communication games, we show a direct correspondence with correlations in spacelike separated events obeying the no-signaling principle. Using this, we prove that all mixed quantum states of any finite dimension are preparation contextual. We report on an experimental realization of a communication game involving three-level quantum systems from which we observe a strong violation of the constraints of preparation noncontextuality.

  16. Fast probabilistic file fingerprinting for big data.

    Science.gov (United States)

    Tretyakov, Konstantin; Laur, Sven; Smant, Geert; Vilo, Jaak; Prins, Pjotr

    2013-01-01

    Biological data acquisition is raising new challenges, both in data analysis and handling. Not only is it proving hard to analyze the data at the rate it is generated today, but simply reading and transferring data files can be prohibitively slow due to their size. This primarily concerns logistics within and between data centers, but is also important for workstation users in the analysis phase. Common usage patterns, such as comparing and transferring files, are proving computationally expensive and are tying down shared resources. We present an efficient method for calculating file uniqueness for large scientific data files, that takes less computational effort than existing techniques. This method, called Probabilistic Fast File Fingerprinting (PFFF), exploits the variation present in biological data and computes file fingerprints by sampling randomly from the file instead of reading it in full. Consequently, it has a flat performance characteristic, correlated with data variation rather than file size. We demonstrate that probabilistic fingerprinting can be as reliable as existing hashing techniques, with provably negligible risk of collisions. We measure the performance of the algorithm on a number of data storage and access technologies, identifying its strengths as well as limitations. Probabilistic fingerprinting may significantly reduce the use of computational resources when comparing very large files. Utilisation of probabilistic fingerprinting techniques can increase the speed of common file-related workflows, both in the data center and for workbench analysis. The implementation of the algorithm is available as an open-source tool named pfff, as a command-line tool as well as a C library. The tool can be downloaded from http://biit.cs.ut.ee/pfff.

  17. A self-consistent model for polycrystal deformation. Description and implementation

    Energy Technology Data Exchange (ETDEWEB)

    Clausen, B.; Lorentzen, T.

    1997-04-01

    This report is a manual for the ANSI C implementation of an incremental elastic-plastic rate-insensitive self-consistent polycrystal deformation model based on (Hutchinson 1970). The model is furthermore described in the Ph.D. thesis by Clausen (Clausen 1997). The structure of the main program, sc{sub m}odel.c, and its subroutines are described with flow-charts. Likewise the pre-processor, sc{sub i}ni.c, is described with a flowchart. Default values of all the input parameters are given in the pre-processor, but the user is able to select from other pre-defined values or enter new values. A sample calculation is made and the results are presented as plots and examples of the output files are shown. (au) 4 tabs., 28 ills., 17 refs.

  18. 77 FR 34030 - BOST1 Hydroelectric LLC; Notice of Intent To File License Application, Filing of Pre-Application...

    Science.gov (United States)

    2012-06-08

    ... Hydroelectric LLC; Notice of Intent To File License Application, Filing of Pre-Application Document, and.... Date Filed: March 21, 2012. d. Submitted By: BOST1 Hydroelectric LLC (BOST1). e. Name of Project: Coon Rapids Dam Hydroelectric Project. f. Location: Mississippi River in Hennepin and Anoka counties...

  19. High-Performance, Multi-Node File Copies and Checksums for Clustered File Systems

    Science.gov (United States)

    Kolano, Paul Z.; Ciotti, Robert B.

    2012-01-01

    Modern parallel file systems achieve high performance using a variety of techniques, such as striping files across multiple disks to increase aggregate I/O bandwidth and spreading disks across multiple servers to increase aggregate interconnect bandwidth. To achieve peak performance from such systems, it is typically necessary to utilize multiple concurrent readers/writers from multiple systems to overcome various singlesystem limitations, such as number of processors and network bandwidth. The standard cp and md5sum tools of GNU coreutils found on every modern Unix/Linux system, however, utilize a single execution thread on a single CPU core of a single system, and hence cannot take full advantage of the increased performance of clustered file systems. Mcp and msum are drop-in replacements for the standard cp and md5sum programs that utilize multiple types of parallelism and other optimizations to achieve maximum copy and checksum performance on clustered file systems. Multi-threading is used to ensure that nodes are kept as busy as possible. Read/write parallelism allows individual operations of a single copy to be overlapped using asynchronous I/O. Multinode cooperation allows different nodes to take part in the same copy/checksum. Split-file processing allows multiple threads to operate concurrently on the same file. Finally, hash trees allow inherently serial checksums to be performed in parallel. Mcp and msum provide significant performance improvements over standard cp and md5sum using multiple types of parallelism and other optimizations. The total speed-ups from all improvements are significant. Mcp improves cp performance over 27x, msum improves md5sum performance almost 19x, and the combination of mcp and msum improves verified copies via cp and md5sum by almost 22x. These improvements come in the form of drop-in replacements for cp and md5sum, so are easily used and are available for download as open source software at http://mutil.sourceforge.net.

  20. 75 FR 68340 - Combined Notice of Filings # 1

    Science.gov (United States)

    2010-11-05

    ... Project, LP; Southern Company--Florida LLC. Description: Report of Non-Material Change in Estimated Coal... Energy Ohio, Inc. submits tariff filing per 35: Compliance Filing to be effective 7/29/2010. Filed Date..., Inc. Description: Midwest Independent Transmission System Operator, Inc. submits tariff filing per 35...

  1. Ground-Based Global Navigation Satellite System GLONASS (GLObal NAvigation Satellite System) Combined Broadcast Ephemeris Data (daily files) from NASA CDDIS

    Data.gov (United States)

    National Aeronautics and Space Administration — This dataset consists of ground-based Global Navigation Satellite System (GNSS) GLONASS Combined Broadcast Ephemeris Data (daily files of all distinct navigation...

  2. Incidence of Deformation and Fracture of Twisted File Adaptive Instruments after Repeated Clinical Use

    Directory of Open Access Journals (Sweden)

    Gianluca Gambarini

    2017-01-01

    Full Text Available Objectives: The aim of the present study was to investigate the incidence of deformation and fracture of twisted file adaptive nickel-titanium instruments after repeated clinical use and to identify and check whether the three instruments within the small/medium sequence showed similar or different visible signs of metal fatigue. Material and Methods: One-hundred twenty twisted file adaptive (TFA packs were collected after clinically used to prepare three molars and were inspected for deformations and fracture. Results: The overall incidence of deformation was 22.2%, which was not evenly distributed within the instruments: 15% for small/medium (SM1 (n = 18, 38.33% for SM2 (n = 46 and 13.33% for the SM3 instruments (n = 16. The defect rate of SM2 instruments was statistically higher than the other two (P < 0.001. The fracture rate was 0.83% (n = 3, being two SM2 instruments and one SM3. Conclusions: It was observed a very low defect rate after clinical use of twisted file adaptive rotary instruments. The untwisting of flutes was significantly more frequent than fracture, which might act as prevention for breakage. The results highlight the fact that clinicians should be aware that instruments within a sequence might be differently subjected to intracanal stress.

  3. 75 FR 81264 - Public Utility District No. 1 of Douglas County; Notice of Intent To Prepare an Environmental...

    Science.gov (United States)

    2010-12-27

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 2149-152] Public Utility District No. 1 of Douglas County; Notice of Intent To Prepare an Environmental Impact Statement December 16, 2010. On May 27, 2010, Public Utility District No. 1 of Douglas County filed an application for the...

  4. 77 FR 68764 - Parker Knoll Hydro, LLC; Notice of Intent To Prepare An Environmental Impact Statement and Notice...

    Science.gov (United States)

    2012-11-16

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 13239-002] Parker Knoll Hydro, LLC; Notice of Intent To Prepare An Environmental Impact Statement and Notice of Scoping Meetings and Soliciting Scoping Comments Take notice that the following hydroelectric applications have been filed with Commission and are available for...

  5. 77 FR 105 - Combined Notice of Filings #2

    Science.gov (United States)

    2012-01-03

    ... tariff filing per 35.17(b): Effective Date Change for ``Fully Integrated'' DR Rules to be effective 6/1... Numbers: ER12-10-001. Applicants: Energy International Power Marketing. Description: Energy International Power Marketing submits tariff filing per 35: EIP Compliance Filing to be effective 10/3/2011. Filed...

  6. Establishment of data base files of thermodynamic data developed by OECD/NEA. Pt. 2. Thermodynamic data of Tc, U, Np, Pu and Am with auxiliary species

    International Nuclear Information System (INIS)

    Yoshida, Yasushi; Shibata, Masahiro

    2005-03-01

    Thermodynamic data base for compounds and complexes of actinides and fission products with auxiliary species specialized in modeling requirements for safety assessment of radioactive waste disposal systems are being developed by NEA TDB project of OECD/NEA. In this project, relevant data bases for compounds and complexes of U, Am, Tc, Np and Pu with auxiliary species were updated and published in 2003. JNC established the data base files available for geochemical calculation codes using these updated data. The procedure for establishment and contents of data base files are described in this report. These data base files were prepared as the formats of major geochemical codes PHREEQE, PHREEQC, EQ3/6 and Geochemist's workbench. Additionally modification for data in the thermodynamic data base files which had been already published by JNC was also done. This procedure and revised data bases are shown in the appendix of this report. (author)

  7. Root canal preparation with Er:YSGG laser

    Science.gov (United States)

    Benthin, Hartmut; Ertl, Thomas P.; Onal, B.; Schruender, Stephan; Mueller, Gerhard J.

    1994-12-01

    The high level of efficiency of hard tissue ablation with Er:YAG and Er:YSGG lasers is well known. Of these lasers it is possible only to transmit Er:YSGG laser radiation with OH reduced quartz fibers. Most of the fibers we use in this study were prepared as hemispherical fiber tips. Fifty single rooted teeth were divided into ten groups (n equals 5). After conventional opening of the pulp chamber, root canal preparation was performed in five groups under water only using the laser. In the other five groups preparation with K-files to size 35 was performed before treatment with laser radiation. All teeth were axially separated with direct access to the root canal and examined in SEM investigations. The groups were compared by measuring the areas with patent dentin tubules. Representative areas were examined by TEM. The temperature at the root surface was measured during laser irradiation with thermocouples positioned at several points. The in-vitro study of the effect of the high delivered energy (50 - 100 mJ per pulse) in the root canal showed a good ablation effect. Most of the dentin tubules were opened. The increase in temperature at the root surface was tolerable.

  8. Design and application of remote file management system

    International Nuclear Information System (INIS)

    Zhu Haijun; Liu Dekang; Shen liren

    2006-01-01

    File transfer protocol can help users transfer files between computers on internet. FTP can not fulfill the needs of users in special occasions, so it needs programmer define file transfer protocol himself based on users. The method or realization and application for user-defined file transfer protocol is introduced. (authors)

  9. 37 CFR 360.21 - Time of filing.

    Science.gov (United States)

    2010-07-01

    ... OF ROYALTY CLAIMS FILING OF CLAIMS TO ROYALTY FEES COLLECTED UNDER COMPULSORY LICENSE Digital Audio... purposes of royalties filing and fee distribution. Such written authorization, however, will not be... members or affiliates before the Copyright Royalty Board in royalty filing and fee distribution...

  10. X-Files opjat v stroju

    Index Scriptorium Estoniae

    2008-01-01

    USA sarjale "The X-Files" põhinev teine järjefilm "Salatoimikud: Ma tahan uskuda" ("The X-Files: I Want to Believe") : režissöör Chris Carter : peaosades David Duchovny, Gillian Anderson : Ameerika Ühendriigid - Kanada 2008

  11. 29 CFR 1979.103 - Filing of discrimination complaint.

    Science.gov (United States)

    2010-07-01

    ... subcontractor of an air carrier in violation of the Act may file, or have filed by any person on the employee's... acts and omissions, with pertinent dates, which are believed to constitute the violations. (c) Place of filing. The complaint should be filed with the OSHA Area Director responsible for enforcement activities...

  12. 76 FR 6125 - Combined Notice of Filings #1

    Science.gov (United States)

    2011-02-03

    ... filing per 35: Arthur Kill--Amendment to MBR Tariff 01262011 to be effective 10/8/ 2010. Filed Date: 01... Turbine Power LLC submits tariff filing per 35: Astoria--Amendment to MBR Tariff 01/26/2011 to be... Description: Conemaugh Power LLC submits tariff filing per 35: Conemaugh--Amendment to MBR Tariff 01262011 to...

  13. 77 FR 43820 - Combined Notice of Filings #1

    Science.gov (United States)

    2012-07-26

    .... Docket Numbers: ER12-1946-001. Applicants: Duke Energy Beckjord, LLC. Description: Amendment to MBR...: Amendment to MBR Tariff Filing to be effective 10/1/ 2012. Filed Date: 7/18/12. Accession Number: 20120718... Creek, LLC. Description: Amendment to MBR Tariff Filing to be effective 10/1/ 2012. Filed Date: 7/18/12...

  14. 77 FR 60418 - Combined Notice of Filings

    Science.gov (United States)

    2012-10-03

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings Take notice that the Commission has received the following Natural Gas Pipeline Rate and Refund Report filings...-1064-000. Applicants: Venice Gathering System, L.L.C. Description: NAESB 2.0 Compliance Filing to be...

  15. An exploratory discussion on business files compilation

    International Nuclear Information System (INIS)

    Gao Chunying

    2014-01-01

    Business files compilation for an enterprise is a distillation and recreation of its spiritual wealth, from which the applicable information can be available to those who want to use it in a fast, extensive and precise way. Proceeding from the effects of business files compilation on scientific researches, productive constructions and developments, this paper in five points discusses the way how to define topics, analyze historical materials, search or select data and process it to an enterprise archives collection. Firstly, to expound the importance and necessity of business files compilation in production, operation and development of an company; secondly, to present processing methods from topic definition, material searching and data selection to final examination and correction; thirdly, to define principle and classification in order to make different categories and levels of processing methods available to business files compilation; fourthly, to discuss the specific method how to implement a file compilation through a documentation collection upon principle of topic definition gearing with demand; fifthly, to address application of information technology to business files compilation in view point of widely needs for business files so as to level up enterprise archives management. The present discussion focuses on the examination and correction principle of enterprise historical material compilation and the basic classifications as well as the major forms of business files compilation achievements. (author)

  16. Comparison of the Effect of Canal Preparation by Step Back Technique Using Hand Instruments and Gates Glidden Drills with ProTaper Universal Rotary System on the Root Resistance to Vertical Fracture

    Directory of Open Access Journals (Sweden)

    A Abbaszadegan

    2013-06-01

    Full Text Available Introduction: Cleaning and shaping of the root canal system with an efficient and safe technique are the major goals of root canal treatment. The aim of this study was to compare the conventional root canal preparation technique by hand instruments and Gates Glidden drills with ProTaper Universal Rotary system on the root susceptibility to vertical fracture. Methods: Thirty extracted human mandibular premolars were randomly assigned to two groups. In group I, apical preparation was performed with k-files up to #40 utilizing step back technique and coronal flaring was done with Gates Glidden drills. In group II, ProTaper Universal Rotary instruments were used up to the file F4. All teeth were obturated with lateral compaction technique using gutta-percha and AH26 sealer. A simulated periodontal ligament was fabricated, and the teeth were mounted. A stainless steel finger spreader #35 was mounted in an Instron testing machine and the necessary load to cause a root fracture was inserted and recorded. The obtained data were analyzed statistically using T-test. Results: The force required to fracture was significantly lower for the roots prepared by ProTaper instruments in comparison with the specimens prepared by hand instruments and Gates Glidden drills (P< 0.001. Conclusion: Canal preparation with ProTaper rotary instruments can make the roots more susceptible to vertical fracture than traditional instrumentation with k-files and Gates Glidden drills.

  17. Fire retardancy assessment of polypropylene composite filed with nano clay prepared from Iraqi bentonite

    Science.gov (United States)

    Kareem Salih, Watheq

    2018-05-01

    Fire retardants have an extraordinary importance because of their role in saving the people, property and reducing the damages and minimizing the dangers resulting from fires and burning of polymeric composites which are used in different civil and industrial fields. The work in this paper can be divided into two main stages. In first one nano-clay was manufactured from Iraqi bentonite and it was characterized using AFM, XRD, XRF, SEM, and BET. The AFM test showed the particle size of prepared nano clay was about 99.25 nm. In the second stage, polypropylene/nano clay composites at three low loading percents (0%,2%,4%,6%) were formulated via twin screw extruder. The fire retardancy tests included burning rate according to ASTM:D-635 and maximum flame height of flame according to ASTM:D-3014. Besides, the mechanical tests and thermal behavior of prepared samples were investigated. The results showed that (4%) of nano-clay had the maximum fire retardancy and while at (2%) loading, the maximum value of tensile strength and Yong modulus were obtained. The maximum heat of fusion was recorded for 6% nano clay sample. The final results assessment confirmed on the possibility of using low loadings of prepared nano clay to improve the fire retardancy, mechanical and thermal properties successfully.

  18. 75 FR 62371 - Combined Notice of Filings #2

    Science.gov (United States)

    2010-10-08

    .... Description: Weyerhaeuser NR Company submits tariff filing per 35.12: Weyerhaeuser NR Company MBR Tariff to be..., Inc. MBR eTariff Filing to be effective 9/30/2010. Filed Date: 09/30/2010. Accession Number: 20100930... 35.12: Chandler Wind Partners, LLC MBR Tariff to be effective 9/30/ 2010. Filed Date: 09/30/2010...

  19. Collective operations in a file system based execution model

    Science.gov (United States)

    Shinde, Pravin; Van Hensbergen, Eric

    2013-02-19

    A mechanism is provided for group communications using a MULTI-PIPE synthetic file system. A master application creates a multi-pipe synthetic file in the MULTI-PIPE synthetic file system, the master application indicating a multi-pipe operation to be performed. The master application then writes a header-control block of the multi-pipe synthetic file specifying at least one of a multi-pipe synthetic file system name, a message type, a message size, a specific destination, or a specification of the multi-pipe operation. Any other application participating in the group communications then opens the same multi-pipe synthetic file. A MULTI-PIPE file system module then implements the multi-pipe operation as identified by the master application. The master application and the other applications then either read or write operation messages to the multi-pipe synthetic file and the MULTI-PIPE synthetic file system module performs appropriate actions.

  20. Search the SEC website for the latest EDGAR filings

    Data.gov (United States)

    Securities and Exchange Commission — This listing contains the most recent filings for the current official filing date (including filings made after the 5:30pm deadline on the previous filing day)....

  1. 77 FR 27221 - Combined Notice of Filings

    Science.gov (United States)

    2012-05-09

    ... Generator Status of Minonk Wind, LLC. Filed Date: 4/19/12. Accession Number: 20120419-5196. Comments Due: 5... Self-Certification of Exempt Wholesale Generator Status of Senate Wind, LLC. Filed Date: 4/19/12... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings Take notice...

  2. 21 CFR 720.2 - Times for filing.

    Science.gov (United States)

    2010-04-01

    ... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) COSMETICS VOLUNTARY FILING OF COSMETIC PRODUCT INGREDIENT COMPOSITION STATEMENTS § 720.2 Times for filing. Within 180 days after forms are made available to the industry, Form FDA 2512 should be filed for each cosmetic...

  3. 75 FR 51451 - Erie Boulevard Hydropower, L.P.; Notice of Intent To File License Application, Filing of Pre...

    Science.gov (United States)

    2010-08-20

    ... Hydropower, L.P.; Notice of Intent To File License Application, Filing of Pre-Application Document, and.... Project No.: 7320-040. c. Dated Filed: June 29, 2010. d. Submitted By: Erie Boulevard Hydropower, L.P. e...: John Mudre at (202) 502-8902; or e-mail at [email protected] . j. Erie Boulevard Hydropower, L.P...

  4. Flexibility and Performance of Parallel File Systems

    Science.gov (United States)

    Kotz, David; Nieuwejaar, Nils

    1996-01-01

    As we gain experience with parallel file systems, it becomes increasingly clear that a single solution does not suit all applications. For example, it appears to be impossible to find a single appropriate interface, caching policy, file structure, or disk-management strategy. Furthermore, the proliferation of file-system interfaces and abstractions make applications difficult to port. We propose that the traditional functionality of parallel file systems be separated into two components: a fixed core that is standard on all platforms, encapsulating only primitive abstractions and interfaces, and a set of high-level libraries to provide a variety of abstractions and application-programmer interfaces (API's). We present our current and next-generation file systems as examples of this structure. Their features, such as a three-dimensional file structure, strided read and write interfaces, and I/O-node programs, are specifically designed with the flexibility and performance necessary to support a wide range of applications.

  5. Evaluated nuclear data file of Th-232

    International Nuclear Information System (INIS)

    Meadows, J.; Poenitz, W.; Smith, A.; Smith, D.; Whalen, J.; Howerton, R.

    1977-09-01

    An evaluated nuclear data file for thorium is described. The file extends over the energy range 0.049 (i.e., the inelastic-scattering threshold) to 20.0 MeV and is formulated within the framework of the ENDF system. The input data base, the evaluation procedures and judgments, and ancillary experiments carried out in conjunction with the evaluation are outlined. The file includes: neutron total cross sections, neutron scattering processes, neutron radiative capture cross sections, fission cross sections, (n;2n) and (n;3n) processes, fission properties (e.g., nu-bar and delayed neutron emission) and photon production processes. Regions of uncertainty are pointed out particularly where new measured results would be of value. The file is extended to thermal energies using previously reported resonance evaluations thereby providing a complete file for neutronic calculations. Integral data tests indicated that the file was suitable for neutronic calculations in the MeV range

  6. 78 FR 20901 - Combined Notice of Filings #1

    Science.gov (United States)

    2013-04-08

    ... Marketing Inc. submits Category Seller Clarification to be effective 3/29/2013. Filed Date: 3/29/13... submits Cost- Based Tariffs Compliance Filing to be effective 4/1/2013. Filed Date: 3/29/13. Accession... to be effective N/A. Filed Date: 3/29/13. Accession Number: 20130329-5223. Comments Due: 5 p.m. ET 4...

  7. 29 CFR 24.103 - Filing of retaliation complaint.

    Science.gov (United States)

    2010-07-01

    ... violations. (c) Place of Filing. The complaint should be filed with the OSHA Area Director responsible for... by an employer in violation of any of the statutes listed in § 24.100(a) may file, or have filed by... with any OSHA officer or employee. Addresses and telephone numbers for these officials are set forth in...

  8. 76 FR 16404 - Combined Notice of Filings #1

    Science.gov (United States)

    2011-03-23

    ...: Amendment to MBR Tariff to be effective 5/13/2011. Filed Date: 03/14/2011. Accession Number: 20110314-5272... tariff filing per 35: Amendment to MBR Tariff to be effective 5/13/ 2011. Filed Date: 03/14/2011.... Subsidiary No. 2, Inc. submits tariff filing per 35: Amendment to MBR Tariff to be effective 5/13/ 2011...

  9. 77 FR 33206 - Combined Notice of Filings #2

    Science.gov (United States)

    2012-06-05

    ... tariff filing per 35: High Trail Wind Farm First Revised MBR to be effective 5/26/2012. Filed Date: 5/25... per 35: Old Trail Wind Farm First Revised MBR to be effective 5/26/2012. Filed Date: 5/25/12... First Revised MBR to be effective 6/1/2012. Filed Date: 5/25/12. Accession Number: 20120525-5088...

  10. Wear of K3 and ProTaper files after simulated clinical use in curved canals

    Directory of Open Access Journals (Sweden)

    Patrícia de Almeida Rodrigues Silva e Souza

    2009-01-01

    Full Text Available Objective: To assess wear, after simulated clinical use of K3 (SybronEndo, Orange, CA, EUA and ProTaper files (Dentsply-Maillefer, Tulsa, Oklahoma, EUA in 46 mesiovestibular roots of human maxillary first molars, recently extracted and with mean angulation of 40°.Methods: The teeth were divided as follows: a K3 (SybronEndo, Orange, CA, EUA (with radial bands and b ProTaper (Dentsply-Maillefer, Tulsa, Oklahoma, EUA (without radial bands. The files were assessed by scanning electronic microscopy before first use to visualize fabrication defects, and after 7 and 13 cycles of debridement in the canals. Debridement with files K3 (SybronEndo, Orange, CA, EUA and ProTaper (Dentsply-Maillefer, Tulsa, Oklahoma, EUA was performed in accordance with the manufacturers’ recommendations. The criteria for wear assessment were: defects (stretching, shortening/spiral inversion, presence of craters, oblique cracks and fracture. After assessment by SEM and before they were used, metal barbs on the crest of the spirals and oblique scratches due to the machining process were found in all the files.Results: In the K3 system (SybronEndo, Orange, CA, USA, after being used seven times, all the instruments showed cutting angle defects,and 25/08 and 25/10 had oblique cracks in the body of the active part leading to ductile fracture after being used for the eighth time. In the ProTaper system (Dentsply-Maillefer, Tulsa, Oklahoma, USA, after being used seven times, in addition to cutting angle defects, the files also presented cracks, and ruptile fracture occurred in F3 during use for the thirteenth time. At the end of preparation, craters were seen along the active part of the files.Conclusion: In the final analysis, it was seen that the system are equivalent with regard to the defects found, irrespective of the active part design,being proportional to the number of cycles of use, and these defects could act as points of greater fragility, favoring fracture.

  11. Index files for Belle II - very small skim containers

    Science.gov (United States)

    Sevior, Martin; Bloomfield, Tristan; Kuhr, Thomas; Ueda, I.; Miyake, H.; Hara, T.

    2017-10-01

    The Belle II experiment[1] employs the root file format[2] for recording data and is investigating the use of “index-files” to reduce the size of data skims. These files contain pointers to the location of interesting events within the total Belle II data set and reduce the size of data skims by 2 orders of magnitude. We implement this scheme on the Belle II grid by recording the parent file metadata and the event location within the parent file. While the scheme works, it is substantially slower than a normal sequential read of standard skim files using default root file parameters. We investigate the performance of the scheme by adjusting the “splitLevel” and “autoflushsize” parameters of the root files in the parent data files.

  12. 77 FR 23474 - Combined Notice of Filings

    Science.gov (United States)

    2012-04-19

    ...: Young Gas Storage Company, Ltd. Description: EBB Notice Categories to be effective 5/15/2012. Filed Date... intervention is necessary to become a party to the proceeding. Filings in Existing Proceedings Docket Numbers... requirements, interventions, protests, and service can be found at: http://www.ferc.gov/docs-filing/efiling...

  13. DMFS: A Data Migration File System for NetBSD

    Science.gov (United States)

    Studenmund, William

    2000-01-01

    I have recently developed DMFS, a Data Migration File System, for NetBSD. This file system provides kernel support for the data migration system being developed by my research group at NASA/Ames. The file system utilizes an underlying file store to provide the file backing, and coordinates user and system access to the files. It stores its internal metadata in a flat file, which resides on a separate file system. This paper will first describe our data migration system to provide a context for DMFS, then it will describe DMFS. It also will describe the changes to NetBSD needed to make DMFS work. Then it will give an overview of the file archival and restoration procedures, and describe how some typical user actions are modified by DMFS. Lastly, the paper will present simple performance measurements which indicate that there is little performance loss due to the use of the DMFS layer.

  14. Cleaning Effectiveness of a Reciprocating Single-file and a Conventional Rotary Instrumentation System.

    Science.gov (United States)

    de Carvalho, Fredson Marcio Acris; Gonçalves, Leonardo Cantanhede de Oliveira; Marques, André Augusto Franco; Alves, Vanessa; Bueno, Carlos Eduardo da Silveira; De Martin, Alexandre Sigrist

    2016-01-01

    To compare cleaning effectiveness by histological analysis of a reciprocating single-file system with ProTaper rotary instruments during the preparation of curved root canals in extracted teeth. A total of 40 root canals with curvatures ranging between 20 - 40 degrees were divided into two groups of 20 canals. Canals were prepared to the following apical sizes: Reciproc size 25 (n=20); ProTaper: F2 (n=20). The normal distribution of data was tested by the Kolmogorov-Smirnov test and the values obtained for the test (Mann-Whitney U test, P .05) between the two groups. The application of reciprocating motion during instrumentation did not result in increased debris when compared with continuous rotation motion, even in the apical part of curved canals. Both instruments resulted in debris in the canal lumen, irrespective of the movement kinematics applied.

  15. 831 Files

    Data.gov (United States)

    Social Security Administration — SSA-831 file is a collection of initial and reconsideration adjudicative level DDS disability determinations. (A few hearing level cases are also present, but the...

  16. 47 CFR 1.1704 - Station files.

    Science.gov (United States)

    2010-10-01

    ... System (COALS) § 1.1704 Station files. Applications, notifications, correspondence, electronic filings... Television Relay Service (CARS) are maintained by the Commission in COALS and the Public Reference Room...

  17. 78 FR 70029 - Combined Notice of Filings #1

    Science.gov (United States)

    2013-11-22

    ..., Ameren Energy Marketing Company, AmerenEnergy Resources Generating Company, AmerenEnergy Medina Valley... filing per 35: Integrated Marketplace Second Compliance Filing to be effective 3/ 1/2014. Filed Date: 11...

  18. Design and creation of a direct access nuclear data file

    International Nuclear Information System (INIS)

    Charpentier, P.

    1981-06-01

    General considerations on the structure of instructions and files are reviewed. Design, organization and mode of use of the different files: instruction file, index files, inverted files, automatic analysis and inquiry programs are examined [fr

  19. 37 CFR 11.41 - Filing of papers.

    Science.gov (United States)

    2010-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Filing of papers. 11.41... Disciplinary Proceedings; Jurisdiction, Sanctions, Investigations, and Proceedings § 11.41 Filing of papers. (a... papers filed after the complaint and prior to entry of an initial decision by the hearing officer shall...

  20. 78 FR 13050 - Combined Notice of Filings

    Science.gov (United States)

    2013-02-26

    ... be considered, but intervention is necessary to become a party to the proceeding. Filings in Existing Proceedings Docket Numbers: RP13-106-002. Applicants: Young Gas Storage Company, Ltd. Description: Young NAESB..., protests, and service can be found at: http://www.ferc.gov/docs-filing/efiling/filing-req.pdf . For other...

  1. Software for Managing Personal Files.

    Science.gov (United States)

    Lundeen, Gerald

    1989-01-01

    Discusses the special characteristics of personal file management software and compares four microcomputer software packages: Notebook II with Bibliography and Convert, Pro-Cite with Biblio-Links, askSam, and Reference Manager. Each package is evaluated in terms of the user interface, file maintenance, retrieval capabilities, output, and…

  2. Machine-readable files developed for the High Plains Regional Aquifer-System analysis in parts of Colorado, Kansas, Nebraska, New Mexico, Oklahoma, South Dakota, Texas, and Wyoming

    Science.gov (United States)

    Ferrigno, C.F.

    1986-01-01

    Machine-readable files were developed for the High Plains Regional Aquifer-System Analysis project are stored on two magnetic tapes available from the U.S. Geological Survey. The first tape contains computer programs that were used to prepare, store, retrieve, organize, and preserve the areal interpretive data collected by the project staff. The second tape contains 134 data files that can be divided into five general classes: (1) Aquifer geometry data, (2) aquifer and water characteristics , (3) water levels, (4) climatological data, and (5) land use and water use data. (Author 's abstract)

  3. Effect of Glide Path Creating on Cyclic Fatigue Resistance of Reciproc and Reciproc Blue Nickel-titanium Files: A Laboratory Study.

    Science.gov (United States)

    Özyürek, Taha; Uslu, Gülşah; Yılmaz, Koray; Gündoğar, Mustafa

    2018-06-01

    The purpose of this article was to compare the cyclic fatigue resistance of Reciproc and Reciproc Blue files (VDW GmbH, Munich, Germany) that were used to prepare root canals of mandibular molar teeth with or without a glide path. Sixty Reciproc R25 and 60 Reciproc Blue R25 files were used. The Reciproc and Reciproc Blue groups were divided into 3 subgroups (ie, as received condition, used without a glide path, and used with a glide path). All the instruments were rotated in a stainless steel artificial canal with an inner diameter of 1.5 mm, a 60° angle of curvature, and a radius of curvature of 5 mm until fracture occurred. The number of cycle to fracture was calculated, and the length of the fractured segments was measured. The Kruskal-Wallis test was performed to statistically analyze the data using SPSS 21.0 software (IBM Corp, Armonk, NY) at a 5% significance level. The cyclic fatigue resistance of as received condition Reciproc Blue files was found to be higher than as received condition Reciproc files (P  .05). There was no statistically significant difference in the mean length of the fractured fragments of the instruments (P > .05). Within the limitations of this in vitro study, it was concluded that creating a glide path using ProGlider files had no effect on the cyclic fatigue resistance of RPC and RPC Blue files. Copyright © 2018 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  4. 75 FR 62522 - Combined Notice of Filings No. 3

    Science.gov (United States)

    2010-10-12

    ... filing per 154.203: NAESB EDI Form Filing to be effective 11/1/ 2010. Filed Date: 09/30/2010. Accession....9 EDI Form to be effective 11/1/2010. Filed Date: 09/30/2010. Accession Number: 20100930-5348...

  5. MR-AFS: a global hierarchical file-system

    International Nuclear Information System (INIS)

    Reuter, H.

    2000-01-01

    The next generation of fusion experiments will use object-oriented technology creating the need for world wide sharing of an underlying hierarchical file-system. The Andrew file system (AFS) is a well known and widely spread global distributed file-system. Multiple-resident-AFS (MR-AFS) combines the features of AFS with hierarchical storage management systems. Files in MR-AFS therefore may be migrated on secondary storage, such as roboted tape libraries. MR-AFS is in use at IPP for the current experiments and data originating from super-computer applications. Experiences and scalability issues are discussed

  6. 29 CFR 801.71 - Filing and service.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false Filing and service. 801.71 Section 801.71 Labor Regulations Relating to Labor (Continued) WAGE AND HOUR DIVISION, DEPARTMENT OF LABOR OTHER LAWS APPLICATION OF THE... and Order of Administrative Law Judge § 801.71 Filing and service. (a) Filing. All documents submitted...

  7. An analysis of file system and installation of the file management system for NOS operating system

    International Nuclear Information System (INIS)

    Lee, Young Jai; Park, Sun Hee; Hwang, In Ah; Kim, Hee Kyung

    1992-06-01

    In this technical report, we analyze NOS file structure for Cyber 170-875 and Cyber 960-31 computer system. We also describe functions, procedure and how-to-operate and how-to-use of VDS. VDS is used to manage large files effectively for Cyber computer system. The purpose of the VDS installation is to increase the virtual disk storage by utilizing magnetic tape, to assist the users of the computer system in managing their files, and to enhance the performance of KAERI Cyber computer system. (Author)

  8. DIGITAL ONCOLOGY PATIENT RECORD - HETEROGENEOUS FILE BASED APPROACH

    Directory of Open Access Journals (Sweden)

    Nikolay Sapundzhiev

    2010-12-01

    Full Text Available Introduction: Oncology patients need extensive follow-up and meticulous documentation. The aim of this study was to introduce a simple, platform independent file based system for documentation of diagnostic and therapeutic procedures in oncology patients and test its function.Material and methods: A file-name based system of the type M1M2M3.F2 was introduced, where M1 is a unique identifier for the patient, M2 is the date of the clinical intervention/event, M3 is an identifier for the author of the medical record and F2 is the specific software generated file-name extension.Results: This system is in use at 5 institutions, where a total of 11 persons on 14 different workstations inputted 16591 entries (files for 2370. The merge process was tested on 2 operating systems - when copied together all files sort up as expected by patient, and for each patient in a chronological order, providing a digital cumulative patient record, which contains heterogeneous file formats.Conclusion: The file based approach for storing heterogeneous digital patient related information is an reliable system, which can handle open-source, proprietary, general and custom file formats and seems to be easily scalable. Further development of software for automatic checks of the integrity and searching and indexing of the files is expected to produce a more user-friendly environment

  9. Consistency of color representation in smart phones.

    Science.gov (United States)

    Dain, Stephen J; Kwan, Benjamin; Wong, Leslie

    2016-03-01

    One of the barriers to the construction of consistent computer-based color vision tests has been the variety of monitors and computers. Consistency of color on a variety of screens has necessitated calibration of each setup individually. Color vision examination with a carefully controlled display has, as a consequence, been a laboratory rather than a clinical activity. Inevitably, smart phones have become a vehicle for color vision tests. They have the advantage that the processor and screen are associated and there are fewer models of smart phones than permutations of computers and monitors. Colorimetric consistency of display within a model may be a given. It may extend across models from the same manufacturer but is unlikely to extend between manufacturers especially where technologies vary. In this study, we measured the same set of colors in a JPEG file displayed on 11 samples of each of four models of smart phone (iPhone 4s, iPhone5, Samsung Galaxy S3, and Samsung Galaxy S4) using a Photo Research PR-730. The iPhones are white LED backlit LCD and the Samsung are OLEDs. The color gamut varies between models and comparison with sRGB space shows 61%, 85%, 117%, and 110%, respectively. The iPhones differ markedly from the Samsungs and from one another. This indicates that model-specific color lookup tables will be needed. Within each model, the primaries were quite consistent (despite the age of phone varying within each sample). The worst case in each model was the blue primary; the 95th percentile limits in the v' coordinate were ±0.008 for the iPhone 4 and ±0.004 for the other three models. The u'v' variation in white points was ±0.004 for the iPhone4 and ±0.002 for the others, although the spread of white points between models was u'v'±0.007. The differences are essentially the same for primaries at low luminance. The variation of colors intermediate between the primaries (e.g., red-purple, orange) mirror the variation in the primaries. The variation in

  10. 77 FR 23708 - Combined Notice of Filings #2

    Science.gov (United States)

    2012-04-20

    ... submits tariff filing per 35.13(a)(2)(iii: 11--20120413 I&M Oper Co MBR Conc to be effective 1/1/2012... filing per 35.13(a)(2)(iii: 12--20120413 KPCo Oper Co MBR Conc to be effective 1/ 1/2012. Filed Date: 4... OPCo Oper Co MBR Conc to be effective 1/ 1/2012. Filed Date: 4/13/12. Accession Number: 20120413-5179...

  11. Grammar-Based Specification and Parsing of Binary File Formats

    Directory of Open Access Journals (Sweden)

    William Underwood

    2012-03-01

    Full Text Available The capability to validate and view or play binary file formats, as well as to convert binary file formats to standard or current file formats, is critically important to the preservation of digital data and records. This paper describes the extension of context-free grammars from strings to binary files. Binary files are arrays of data types, such as long and short integers, floating-point numbers and pointers, as well as characters. The concept of an attribute grammar is extended to these context-free array grammars. This attribute grammar has been used to define a number of chunk-based and directory-based binary file formats. A parser generator has been used with some of these grammars to generate syntax checkers (recognizers for validating binary file formats. Among the potential benefits of an attribute grammar-based approach to specification and parsing of binary file formats is that attribute grammars not only support format validation, but support generation of error messages during validation of format, validation of semantic constraints, attribute value extraction (characterization, generation of viewers or players for file formats, and conversion to current or standard file formats. The significance of these results is that with these extensions to core computer science concepts, traditional parser/compiler technologies can potentially be used as a part of a general, cost effective curation strategy for binary file formats.

  12. 75 FR 49918 - Combined Notice of Filings # 1

    Science.gov (United States)

    2010-08-16

    ... Missouri Operations Company submits tariff filing per 35: KCP&L-GMO Baseline Compliance Filing to be.... Description: KCP&L Greater Missouri Operations Company submits tariff filing per 35.12: KCP&L-GMO OATT Volume...

  13. H++ 3.0: automating pK prediction and the preparation of biomolecular structures for atomistic molecular modeling and simulations.

    Science.gov (United States)

    Anandakrishnan, Ramu; Aguilar, Boris; Onufriev, Alexey V

    2012-07-01

    The accuracy of atomistic biomolecular modeling and simulation studies depend on the accuracy of the input structures. Preparing these structures for an atomistic modeling task, such as molecular dynamics (MD) simulation, can involve the use of a variety of different tools for: correcting errors, adding missing atoms, filling valences with hydrogens, predicting pK values for titratable amino acids, assigning predefined partial charges and radii to all atoms, and generating force field parameter/topology files for MD. Identifying, installing and effectively using the appropriate tools for each of these tasks can be difficult for novice and time-consuming for experienced users. H++ (http://biophysics.cs.vt.edu/) is a free open-source web server that automates the above key steps in the preparation of biomolecular structures for molecular modeling and simulations. H++ also performs extensive error and consistency checking, providing error/warning messages together with the suggested corrections. In addition to numerous minor improvements, the latest version of H++ includes several new capabilities and options: fix erroneous (flipped) side chain conformations for HIS, GLN and ASN, include a ligand in the input structure, process nucleic acid structures and generate a solvent box with specified number of common ions for explicit solvent MD.

  14. Adding Data Management Services to Parallel File Systems

    Energy Technology Data Exchange (ETDEWEB)

    Brandt, Scott [Univ. of California, Santa Cruz, CA (United States)

    2015-03-04

    The objective of this project, called DAMASC for “Data Management in Scientific Computing”, is to coalesce data management with parallel file system management to present a declarative interface to scientists for managing, querying, and analyzing extremely large data sets efficiently and predictably. Managing extremely large data sets is a key challenge of exascale computing. The overhead, energy, and cost of moving massive volumes of data demand designs where computation is close to storage. In current architectures, compute/analysis clusters access data in a physically separate parallel file system and largely leave it scientist to reduce data movement. Over the past decades the high-end computing community has adopted middleware with multiple layers of abstractions and specialized file formats such as NetCDF-4 and HDF5. These abstractions provide a limited set of high-level data processing functions, but have inherent functionality and performance limitations: middleware that provides access to the highly structured contents of scientific data files stored in the (unstructured) file systems can only optimize to the extent that file system interfaces permit; the highly structured formats of these files often impedes native file system performance optimizations. We are developing Damasc, an enhanced high-performance file system with native rich data management services. Damasc will enable efficient queries and updates over files stored in their native byte-stream format while retaining the inherent performance of file system data storage via declarative queries and updates over views of underlying files. Damasc has four key benefits for the development of data-intensive scientific code: (1) applications can use important data-management services, such as declarative queries, views, and provenance tracking, that are currently available only within database systems; (2) the use of these services becomes easier, as they are provided within a familiar file

  15. Dynamic Non-Hierarchical File Systems for Exascale Storage

    Energy Technology Data Exchange (ETDEWEB)

    Long, Darrell E. [Univ. of California, Santa Cruz, CA (United States); Miller, Ethan L [Univ. of California, Santa Cruz, CA (United States)

    2015-02-24

    This constitutes the final report for “Dynamic Non-Hierarchical File Systems for Exascale Storage”. The ultimate goal of this project was to improve data management in scientific computing and high-end computing (HEC) applications, and to achieve this goal we proposed: to develop the first, HEC-targeted, file system featuring rich metadata and provenance collection, extreme scalability, and future storage hardware integration as core design goals, and to evaluate and develop a flexible non-hierarchical file system interface suitable for providing more powerful and intuitive data management interfaces to HEC and scientific computing users. Data management is swiftly becoming a serious problem in the scientific community – while copious amounts of data are good for obtaining results, finding the right data is often daunting and sometimes impossible. Scientists participating in a Department of Energy workshop noted that most of their time was spent “...finding, processing, organizing, and moving data and it’s going to get much worse”. Scientists should not be forced to become data mining experts in order to retrieve the data they want, nor should they be expected to remember the naming convention they used several years ago for a set of experiments they now wish to revisit. Ideally, locating the data you need would be as easy as browsing the web. Unfortunately, existing data management approaches are usually based on hierarchical naming, a 40 year-old technology designed to manage thousands of files, not exabytes of data. Today’s systems do not take advantage of the rich array of metadata that current high-end computing (HEC) file systems can gather, including content-based metadata and provenance1 information. As a result, current metadata search approaches are typically ad hoc and often work by providing a parallel management system to the “main” file system, as is done in Linux (the locate utility), personal computers, and enterprise search

  16. 77 FR 23241 - Lock+ Hydro Friends Fund XXX, LLC; Notice of Intent To File License Application, Filing of Pre...

    Science.gov (United States)

    2012-04-18

    ... Friends Fund XXX, LLC; Notice of Intent To File License Application, Filing of Pre-Application Document.... Date Filed: February 20, 2012. d. Submitted By: Lock+ Hydro Friends Fund XXX, LLC. e. Name of Project... Applicant Contact: Mr. Mark R. Stover, Lock+\\TM\\ Hydro Friends Fund XXX, c/o Hydro Green Energy, LLC, 900...

  17. Analyzing endosonic root canal file oscillations: an in vitro evaluation.

    Science.gov (United States)

    Lea, Simon C; Walmsley, A Damien; Lumley, Philip J

    2010-05-01

    Passive ultrasonic irrigation may be used to improve bacterial reduction within the root canal. The technique relies on a small file being driven to oscillate freely within the canal and activating an irrigant solution through biophysical forces such as microstreaming. There is limited information regarding a file's oscillation patterns when operated while surrounded by fluid as is the case within a canal root. Files of different sizes (#10 and #30, 27 mm and 31 mm) were connected to an ultrasound generator via a 120 degrees file holder. Files were immersed in a water bath, and a laser vibrometer set up with measurement lines superimposed over the files. The laser vibrometer was scanned over the oscillating files. Measurements were repeated 10 times for each file/power setting used. File mode shapes are comprised of a series of nodes/antinodes, with thinner, longer files producing more antinodes. The maximum vibration occurred at the free end of the file. Increasing generator power had no significant effect on this maximum amplitude (p > 0.20). Maximum displacement amplitudes were 17 to 22 microm (#10 file, 27 mm), 15 to 21 microm (#10 file, 31 mm), 6 to 9 microm (#30 file, 27 mm), and 5 to 7 microm (#30, 31 mm) for all power settings. Antinodes occurring along the remaining file length were significantly larger at generator power 1 than at powers 2 through 5 (p generator powers, energy delivered to the file is dissipated in unwanted vibration resulting in reduced vibration displacement amplitudes. This may reduce the occurrence of the biophysical forces necessary to maximize the technique's effectiveness. Copyright (c) 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  18. Improving File System Performance by Striping

    Science.gov (United States)

    Lam, Terance L.; Kutler, Paul (Technical Monitor)

    1998-01-01

    This document discusses the performance and advantages of striped file systems on the SGI AD workstations. Performance of several striped file system configurations are compared and guidelines for optimal striping are recommended.

  19. 78 FR 32383 - Combined Notice of Filings #1

    Science.gov (United States)

    2013-05-30

    .... Description: Inquiry Response to be effective 5/12/2013. Filed Date: 5/21/13. Accession Number: 20130521-5167....ferc.gov/docs-filing/efiling/filing-req.pdf . For other information, call (866) 208-3676 (toll free...

  20. 76 FR 24467 - Fire Mountain Lodge; Notice of Application Accepted for Filing, Soliciting Motions To Intervene...

    Science.gov (United States)

    2011-05-02

    .... The existing Fire Mountain Lodge project consists of: (1) A 265- foot-long earth and concrete filled... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 1992-003] Fire Mountain.... Date filed: April 25, 2008. d. Applicant: Mr. Ken Willis. e. Name of Project: Fire Mountain Lodge. f...

  1. 8 CFR 236.14 - Filing.

    Science.gov (United States)

    2010-01-01

    ... 8 Aliens and Nationality 1 2010-01-01 2010-01-01 false Filing. 236.14 Section 236.14 Aliens and Nationality DEPARTMENT OF HOMELAND SECURITY IMMIGRATION REGULATIONS APPREHENSION AND DETENTION OF INADMISSIBLE... initial denial, to allow the alien the opportunity to file a new Form I-817 application in order to...

  2. 76 FR 80921 - Combined Notice of Filings

    Science.gov (United States)

    2011-12-27

    .... Comments Due: 5 p.m. ET 12/27/11. Docket Numbers: RP12-243-000. Applicants: Young Gas Storage Company, Ltd... considered, but intervention is necessary to become a party to the proceeding. The filings are accessible in... can be found at: http://www.ferc.gov/docs-filing/efiling/filing-req.pdf . For other information, call...

  3. 21 CFR 314.420 - Drug master files.

    Science.gov (United States)

    2010-04-01

    ... the context of an application under part 312 or this part. A drug master file may contain information... incorporate by reference all or part of the contents of any drug master file in support of the submission if... information in a drug master file (except the list required under paragraph (d) of this section) is required...

  4. Chronic Condition Public Use File (PUF)

    Data.gov (United States)

    U.S. Department of Health & Human Services — This release contains the Chronic Conditions Public Use Files (PUF) with information from Medicare claims. The CMS Chronic Conditions PUF is an aggregated file in...

  5. Preparation of CH4 for 14C measurements

    International Nuclear Information System (INIS)

    Cechova, A.; Grgula, M.; Povinec, P.; Sivo, A.

    1988-01-01

    An improved method of methane preparation from wood samples is described. It consists of the preparation of α-cellulose to secure a complete removal of contamination from the wood, its combustion to the form of CO 2 and the preparation of CH 4 in a new designed hydrogenation converter. Purified methane is suitable as a gas filling of the proportional counter. (author). 1 fig., 16 ref

  6. Analyzing Log Files using Data-Mining

    Directory of Open Access Journals (Sweden)

    Marius Mihut

    2008-01-01

    Full Text Available Information systems (i.e. servers, applications and communication devices create a large amount of monitoring data that are saved as log files. For analyzing them, a data-mining approach is helpful. This article presents the steps which are necessary for creating an ‘analyzing instrument’, based on an open source software called Waikato Environment for Knowledge Analysis (Weka [1]. For exemplification, a system log file created by a Windows-based operating system, is used as input file.

  7. 77 FR 3758 - Combined Notice of Filings #1

    Science.gov (United States)

    2012-01-25

    ...: Attachment H Schedule 7 Compliance Filing to be effective 6/1/2011. Filed Date: 1/13/12. Accession Number... filings: Docket Numbers: QF12-159-000. Applicants: City of Kinston, NC. Description: FERC Form 556 of City...

  8. EPA FRS Facilities State Single File CSV Download

    Science.gov (United States)

    This page provides state comma separated value (CSV) files containing key information of all facilities and sites within the Facility Registry System (FRS). Each state zip file contains a single CSV file of key facility-level information.

  9. 77 FR 12830 - Pershing County Water Conservation District; Notice of Intent To File License Application, Filing...

    Science.gov (United States)

    2012-03-02

    ... Water Conservation District; Notice of Intent To File License Application, Filing of Pre-Application.... Submitted by: Pershing County Water Conservation District (Pershing County). e. Name of Project: Humboldt... the Commission's regulations. h. Potential Applicant Contact: Bennie Hodges, Pershing County Water...

  10. Histological evaluation of the cleaning effectiveness of two reciprocating single-file systems in severely curved root canals: Reciproc versus WaveOne.

    Science.gov (United States)

    Carvalho, Maira de Souza; Junior, Emílio Carlos Sponchiado; Bitencourt Garrido, Angela Delfina; Roberti Garcia, Lucas da Fonseca; Franco Marques, André Augusto

    2015-01-01

    The aim of this study was to evaluate the cleaning effectiveness achieved with two reciprocating single-file systems in severely curved root canals: Reciproc and WaveOne. Twenty-five mesial roots of mandibular molars were randomly separated into two groups, according to the instrumentation system used. The negative control group consisted of five specimens that were not instrumented. The mesial canals (buccal and lingual) in Reciproc Group were instrumented with file R25 and the WaveOne group with the Primary file. The samples were submitted to histological processing and analyzed under a digital microscope. The WaveOne group presented a larger amount of debris than the Reciproc Group, however, without statistically significant difference (P > 0.05). A larger amount of debris in the control group was observed, with statistically significant difference to Reciproc and WaveOne groups (P file instrumentation systems presented similar effectiveness for root canal cleaning.

  11. Ambulance Reasonable Charge Public Use Files

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Ambulance Reasonable Charge public use files for calendar years (CY) 2003 through 2005 are located in the Downloads section below. These public use files are...

  12. Portable File Format (PFF) specifications

    Energy Technology Data Exchange (ETDEWEB)

    Dolan, Daniel H. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-02-01

    Created at Sandia National Laboratories, the Portable File Format (PFF) allows binary data transfer across computer platforms. Although this capability is supported by many other formats, PFF files are still in use at Sandia, particularly in pulsed power research. This report provides detailed PFF specifications for accessing data without relying on legacy code.

  13. ACONC Files

    Data.gov (United States)

    U.S. Environmental Protection Agency — ACONC files containing simulated ozone and PM2.5 fields that were used to create the model difference plots shown in the journal article. This dataset is associated...

  14. Flat Files - JSNP | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data ... Data file File name: jsnp_flat_files File URL: ftp://ftp.biosciencedbc.jp/archiv...his Database Database Description Download License Update History of This Database Site Policy | Contact Us Flat Files - JSNP | LSDB Archive ...

  15. Case file coding of child maltreatment: Methods, challenges, and innovations in a longitudinal project of youth in foster care☆

    Science.gov (United States)

    Huffhines, Lindsay; Tunno, Angela M.; Cho, Bridget; Hambrick, Erin P.; Campos, Ilse; Lichty, Brittany; Jackson, Yo

    2016-01-01

    State social service agency case files are a common mechanism for obtaining information about a child’s maltreatment history, yet these documents are often challenging for researchers to access, and then to process in a manner consistent with the requirements of social science research designs. Specifically, accessing and navigating case files is an extensive undertaking, and a task that many researchers have had to maneuver with little guidance. Even after the files are in hand and the research questions and relevant variables have been clarified, case file information about a child’s maltreatment exposure can be idiosyncratic, vague, inconsistent, and incomplete, making coding such information into useful variables for statistical analyses difficult. The Modified Maltreatment Classification System (MMCS) is a popular tool used to guide the process, and though comprehensive, this coding system cannot cover all idiosyncrasies found in case files. It is not clear from the literature how researchers implement this system while accounting for issues outside of the purview of the MMCS or that arise during MMCS use. Finally, a large yet reliable file coding team is essential to the process, however, the literature lacks training guidelines and methods for establishing reliability between coders. In an effort to move the field toward a common approach, the purpose of the present discussion is to detail the process used by one large-scale study of child maltreatment, the Studying Pathways to Adjustment and Resilience in Kids (SPARK) project, a longitudinal study of resilience in youth in foster care. The article addresses each phase of case file coding, from accessing case files, to identifying how to measure constructs of interest, to dealing with exceptions to the coding system, to coding variables reliably, to training large teams of coders and monitoring for fidelity. Implications for a comprehensive and efficient approach to case file coding are discussed. PMID

  16. Efficiency of the Self Adjusting File, WaveOne, Reciproc, ProTaper and hand files in root canal debridement.

    Science.gov (United States)

    Topcu, K Meltem; Karatas, Ertugrul; Ozsu, Damla; Ersoy, Ibrahim

    2014-07-01

    The aim of this study was to compare the canal debridement capabilities of three single file systems, ProTaper, and K-files in oval-shaped canals. Seventy-five extracted human mandibular central incisors with oval-shaped root canals were selected. A radiopaque contrast medium (Metapex; Meta Biomed Co. Ltd., Chungcheongbuk-do, Korea) was introduced into the canal systems and the self-adjusting file (SAF), WaveOne, Reciproc, ProTaper, and K-files were used for the instrumentation of the canals. The percentage of removed contrast medium was calculated using pre- and post-operative radiographs. An overall comparison between the groups revealed that the hand file (HF) and SAF groups presented the lowest percentage of removed contrast medium, whereas the WaveOne group showed the highest percentage (P ProTaper group removed more contrast medium than the SAF and HF groups (P < 0.05). None of the instruments was able to remove the contrast medium completely. WaveOne performed significantly better than other groups.

  17. Physician-Supplier Procedure Summary Master File

    Data.gov (United States)

    U.S. Department of Health & Human Services — This file is a 100 percent summary of all Part B Carrier and DMERC Claims processed through the Common Working File and stored in the National Claims History...

  18. XML Files

    Science.gov (United States)

    ... this page: https://medlineplus.gov/xml.html MedlinePlus XML Files To use the sharing features on this page, please enable JavaScript. MedlinePlus produces XML data sets that you are welcome to download ...

  19. 75 FR 8919 - Federal Consistency Appeal by Pan American Grain Co.

    Science.gov (United States)

    2010-02-26

    ... by Pan American Grain Co. AGENCY: National Oceanic and Atmospheric Administration (NOAA), Department... Grain Co., has filed an administrative appeal with the Department of Commerce (Department), requesting..., 2010, Pan American Grain Co. filed notice of an appeal with the Secretary of Commerce (Secretary...

  20. 49 CFR 1104.1 - Address, identification, and electronic filing option.

    Science.gov (United States)

    2010-10-01

    ... 2 of 4” and so forth). (e) Persons filing pleadings and documents with the Board have the option of electronically filing (e-filing) certain types of pleadings and documents instead of filing paper copies. Details regarding the types of pleadings and documents eligible for e-filing, the procedures to be followed, and...

  1. The Effect of File Size and Type and Irrigation Solutions on the Accuracy of Electronic Apex Locators: An In Vitro Study on Canine Teeth.

    Science.gov (United States)

    Janeczek, Maciej; Kosior, Piotr; Piesiak-Pańczyszyn, Dagmara; Dudek, Krzysztof; Chrószcz, Aleksander; Czajczyńska-Waszkiewicz, Agnieszka; Kowalczyk-Zając, Małgorzata; Gabren-Syller, Aleksandra; Kirstein, Karol; Skalec, Aleksandra; Bryła, Ewelina; Dobrzyński, Maciej

    2016-01-01

    Measurements of the root canal during endodontic treatment have a significant influence on the course of the therapeutic process as well as on its final result in both human and veterinary medicine. The apical constriction should be the termination point for the preparation and filling of the root canal. This research was conducted with the use of a Septodont kit consisting of a small chamber filled with the examined solution in which a healthy second incisor was placed. The step back method was applied for the root canal preparation and master apical file of 30 was used. The working length was 22 mm. The examination was conducted with the use of steel as well as nickel titanium hand instruments. Different irrigation solutions and two types of apex locators were used. Measurements of the working length of the root canal showed dependence on the size of the instrument. Examinations carried out in various environments showed that analogical measurements were obtained only for sodium hypochlorite solutions. In other environments the measured sections were shortened. Comparative examinations with the use of steel instruments demonstrated insignificant measurement differences. Compared to these results, the measurements in nickel titanium group were characterized by more considerable deviations.

  2. The Effect of File Size and Type and Irrigation Solutions on the Accuracy of Electronic Apex Locators: An In Vitro Study on Canine Teeth

    Directory of Open Access Journals (Sweden)

    Maciej Janeczek

    2016-01-01

    Full Text Available Measurements of the root canal during endodontic treatment have a significant influence on the course of the therapeutic process as well as on its final result in both human and veterinary medicine. The apical constriction should be the termination point for the preparation and filling of the root canal. This research was conducted with the use of a Septodont kit consisting of a small chamber filled with the examined solution in which a healthy second incisor was placed. The step back method was applied for the root canal preparation and master apical file of 30 was used. The working length was 22 mm. The examination was conducted with the use of steel as well as nickel titanium hand instruments. Different irrigation solutions and two types of apex locators were used. Measurements of the working length of the root canal showed dependence on the size of the instrument. Examinations carried out in various environments showed that analogical measurements were obtained only for sodium hypochlorite solutions. In other environments the measured sections were shortened. Comparative examinations with the use of steel instruments demonstrated insignificant measurement differences. Compared to these results, the measurements in nickel titanium group were characterized by more considerable deviations.

  3. 77 FR 71412 - Combined Notice of Filings #2

    Science.gov (United States)

    2012-11-30

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings 2 Take notice that the Commission has received the following Natural Gas Pipeline Rate and Refund Report filings: Filings Instituting Proceedings Docket Numbers: RP13-301-000. Applicants: Venice Gathering System, LLC...

  4. 76 FR 16398 - Combined Notice of Filings #3

    Science.gov (United States)

    2011-03-23

    .... Applicants: Bangor Hydro Electric Company. Description: Bangor Hydro Electric Company submits tariff filing... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings 3 Take notice that the Commission received the following electric rate filings: Docket Numbers: ER10-2288-004...

  5. 78 FR 67136 - Combined Notice of Filings #2

    Science.gov (United States)

    2013-11-08

    ...: Bangor Hydro Electric Company. Description: Bangor Hydro Electric Company submits Filing to Effect... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings 2 Take notice that the Commission received the following electric corporate filings: Docket Numbers: EC14-15-000...

  6. CONTINUOUS V/S RECIPROCATING FILE MOTION – A REVIEW

    OpenAIRE

    Samrithi Yuvaraj; Dr. S. Delphine Priscilla Antony

    2017-01-01

    Aim: To review the continuous and reciprocating file motions in endodontics Back Ground: The first endodontic file was crafted in the mid 1800’s. Thiis was basically a rudimentary k-file. K-files are, to these days. The most commonly used hand files in clinical practice. Automated instrumentation of the root canal was an early objective of clinical endodontics. Around 1992-1993, the first rotary NiTi instrument was introduced. These rotary NiTi instruments have undergone various modificat...

  7. CryptoCache: A Secure Sharable File Cache for Roaming Users

    DEFF Research Database (Denmark)

    Jensen, Christian D.

    2000-01-01

    . Conventional distributed file systems cache everything locally or not at all; there is no possibility to cache files on nearby nodes.In this paper we present the design of a secure cache system called CryptoCache that allows roaming users to cache files on untrusted file hosting servers. The system allows...... flexible sharing of cached files among unauthenticated users, i.e. unlike most distributed file systems CryptoCache does not require a global authentication framework.Files are encrypted when they are transferred over the network and while stored on untrusted servers. The system uses public key......Small mobile computers are now sufficiently powerful to run many applications, but storage capacity remains limited so working files cannot be cached or stored locally. Even if files can be stored locally, the mobile device is not powerful enough to act as server in collaborations with other users...

  8. De-identifying a public use microdata file from the Canadian national discharge abstract database

    Directory of Open Access Journals (Sweden)

    Paton David

    2011-08-01

    Full Text Available Abstract Background The Canadian Institute for Health Information (CIHI collects hospital discharge abstract data (DAD from Canadian provinces and territories. There are many demands for the disclosure of this data for research and analysis to inform policy making. To expedite the disclosure of data for some of these purposes, the construction of a DAD public use microdata file (PUMF was considered. Such purposes include: confirming some published results, providing broader feedback to CIHI to improve data quality, training students and fellows, providing an easily accessible data set for researchers to prepare for analyses on the full DAD data set, and serve as a large health data set for computer scientists and statisticians to evaluate analysis and data mining techniques. The objective of this study was to measure the probability of re-identification for records in a PUMF, and to de-identify a national DAD PUMF consisting of 10% of records. Methods Plausible attacks on a PUMF were evaluated. Based on these attacks, the 2008-2009 national DAD was de-identified. A new algorithm was developed to minimize the amount of suppression while maximizing the precision of the data. The acceptable threshold for the probability of correct re-identification of a record was set at between 0.04 and 0.05. Information loss was measured in terms of the extent of suppression and entropy. Results Two different PUMF files were produced, one with geographic information, and one with no geographic information but more clinical information. At a threshold of 0.05, the maximum proportion of records with the diagnosis code suppressed was 20%, but these suppressions represented only 8-9% of all values in the DAD. Our suppression algorithm has less information loss than a more traditional approach to suppression. Smaller regions, patients with longer stays, and age groups that are infrequently admitted to hospitals tend to be the ones with the highest rates of suppression

  9. 78 FR 62612 - Combined Notice of Filings #1

    Science.gov (United States)

    2013-10-22

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings 1 Take notice that the Commission received the following electric corporate filings: Docket Numbers: EC14-3-000...: PE Hydro Generation, LLC Description: Self-Certification of EG of PE Hydro Generation, LLC. Filed...

  10. New Steganographic Techniques for the OOXML File Format

    OpenAIRE

    Castiglione , Aniello; D’Alessio , Bonaventura; Santis , Alfredo ,; Palmieri , Francesco

    2011-01-01

    Part 2: Workshop; International audience; The simplest container of digital information is the file and among the vast array of files currently available, MS-Office files are the most widely used. The “Microsoft Compound Document File Format” (MCDFF) has often been used to host secret information. The new format created by Microsoft, first used with MS-Office 2007, makes use of a new standard, the “Office Open XML Formats” (OOXML). The benefits include that the new format introduces the OOXML...

  11. An evaluated neutronic data file for elemental zirconium

    International Nuclear Information System (INIS)

    Smith, A.B.; Chiba, S.

    1994-09-01

    A comprehensive evaluated neutronic data file for elemental zirconium is derived and presented in the ENDF/B-VI formats. The derivation is based upon measured microscopic nuclear data, augmented by model calculations as necessary. The primary objective is a quality contemporary file suitable for fission-reactor development extending from conventional thermal to fast and innovative systems. This new file is a significant improvement over previously available evaluated zirconium files, in part, as a consequence of extensive new experimental measurements reported elsewhere

  12. Surfactant modified clays’ consistency limits and contact angles

    Directory of Open Access Journals (Sweden)

    S Akbulut

    2012-07-01

    Full Text Available This study was aimed at preparing a surfactant modified clay (SMC and researching the effect of surfactants on clays' contact angles and consistency limits; clay was thus modified by surfactants formodifying their engineering properties. Seven surfactants (trimethylglycine, hydroxyethylcellulose  octyl phenol ethoxylate, linear alkylbenzene sulfonic acid, sodium lauryl ether sulfate, cetyl trimethylammonium chloride and quaternised ethoxylated fatty amine were used as surfactants in this study. The experimental results indicated that SMC consistency limits (liquid and plastic limits changedsignificantly compared to those of natural clay. Plasticity index and liquid limit (PI-LL values representing soil class approached the A-line when zwitterion, nonionic, and anionic surfactant percentageincreased. However, cationic SMC became transformed from CH (high plasticity clay to MH (high plasticity silt class soils, according to the unified soil classification system (USCS. Clay modifiedwith cationic and anionic surfactants gave higher and lower contact angles than natural clay, respectively.

  13. Enzymatic sensing of glucose in artificial saliva using a flat electrode consisting of a nanocomposite prepared from reduced graphene oxide, chitosan, nafion and glucose oxidase

    International Nuclear Information System (INIS)

    Rabti, Amal; Argoubi, Wicem; Raouafi, Noureddine

    2016-01-01

    We report on the preparation of a nanoporous flat electrode by drop casting a nanocomposite consisting of reduced graphene oxide (rGO) and chitosan onto a polyester substrate. An underlying conductive surface is not required. The nanocomposite was characterized by scanning electron microscopy and electrochemical impedance spectroscopy. The 3D network of the composite was used as a scaffold for the immobilization of glucose oxidase (GOx). A well-defined signal related to direct GOx electrochemistry was registered and used to monitor levels of glucose. The resulting biosensor displays a linear response to glucose with a detection limit of 5 μM (at an S/N ratio of 3) and a sensitivity of 41.7 μA⋅mM"−"1∙cm"−"2. The sensor was applied to the determination of glucose in artificial saliva. (author)

  14. 42 CFR 430.63 - Filing and service of papers.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Filing and service of papers. 430.63 Section 430.63... Conformity of State Medicaid Plans and Practice to Federal Requirements § 430.63 Filing and service of papers. (a) Filing. All papers in the proceedings are filed with the CMS Docket Clerk, in an original and two...

  15. 45 CFR 1386.85 - Filing and service of papers.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false Filing and service of papers. 1386.85 Section 1386... Requirements General § 1386.85 Filing and service of papers. (a) All papers in the proceedings must be filed... transcripts of testimony need be filed. (b) Copies of papers in the proceedings must be served on all parties...

  16. 10 CFR 13.26 - Filing and service of papers.

    Science.gov (United States)

    2010-01-01

    ... found in the E-Filing Guidance and on the NRC Web site at http://www.nrc.gov/site-help/e-submittals.html... electronically to the E-Filing system. In addition, optical storage media (OSM) containing the entire filing must... document (e.g., motion to quash subpoena). (6) Filing is complete when the filer performs the last act that...

  17. Efficient analysis and extraction of MS/MS result data from Mascot™ result files

    Directory of Open Access Journals (Sweden)

    Sickmann Albert

    2005-12-01

    Full Text Available Abstract Background Mascot™ is a commonly used protein identification program for MS as well as for tandem MS data. When analyzing huge shotgun proteomics datasets with Mascot™'s native tools, limits of computing resources are easily reached. Up to now no application has been available as open source that is capable of converting the full content of Mascot™ result files from the original MIME format into a database-compatible tabular format, allowing direct import into database management systems and efficient handling of huge datasets analyzed by Mascot™. Results A program called mres2x is presented, which reads Mascot™ result files, analyzes them and extracts either selected or all information in order to store it in a single file or multiple files in formats which are easier to handle downstream of Mascot™. It generates different output formats. The output of mres2x in tab format is especially designed for direct high-performance import into relational database management systems using native tools of these systems. Having the data available in database management systems allows complex queries and extensive analysis. In addition, the original peak lists can be extracted in DTA format suitable for protein identification using the Sequest™ program, and the Mascot™ files can be split, preserving the original data format. During conversion, several consistency checks are performed. mres2x is designed to provide high throughput processing combined with the possibility to be driven by other computer programs. The source code including supplement material and precompiled binaries is available via http://www.protein-ms.de and http://sourceforge.net/projects/protms/. Conclusion The database upload allows regrouping of the MS/MS results using a database management system and complex analyzing queries using SQL without the need to run new Mascot™ searches when changing grouping parameters.

  18. 78 FR 49741 - Combined Notice of Filings #1

    Science.gov (United States)

    2013-08-15

    ... that the Commission received the following electric rate filings: Docket Numbers: ER12-1155-001...: ER13-2118-000. Applicants: NedPower Mount Storm, LLC. Description: Compliance Filing--NedPower MBR.../13. Docket Numbers: ER13-2120-000. Applicants: Bangor Hydro Electric Company. Description: Filing of...

  19. 77 FR 37397 - Combined Notice of Filings #1

    Science.gov (United States)

    2012-06-21

    ..., Emera Energy U.S. Subsidiary No. 2, Inc., Bangor Hydro Electric Company. Description: Change in Status Filing of Bangor Hydro Electric Company, et al. Filed Date: 6/13/12. Accession Number: 20120613-5023... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings 1 Take notice...

  20. 75 FR 23752 - Combined Notice of Filings #1

    Science.gov (United States)

    2010-05-04

    ...Corp. Description: PacifiCorp submits Revised Network Integration Transmission Service Agreement dated... Network Integration Transmission Service Agreement et al. Filed Date: 04/26/2010. Accession Numbers... filing per 35.12: Initial Market Based Rates to be effective 6/1/2010. Filed Date: 04/27/2010. Accession...

  1. 78 FR 69407 - Combined Notice of Filings #1

    Science.gov (United States)

    2013-11-19

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings 1 Take notice that the Commission received the following electric corporate filings: Docket Numbers: EC14-24-000... of Eldorado Co-Tenancy and Communication Agreement to be effective 1/1/2014. Filed Date: 11/7/13...

  2. 46 CFR 232.6 - Financial report filing requirement.

    Science.gov (United States)

    2010-10-01

    ... RELATED ACTIVITIES UNIFORM FINANCIAL REPORTING REQUIREMENTS Income Statement § 232.6 Financial report filing requirement. (a) Reporting Frequency and Due Dates. The contractor shall file a semiannual... 46 Shipping 8 2010-10-01 2010-10-01 false Financial report filing requirement. 232.6 Section 232.6...

  3. 75 FR 47262 - Federal Consistency Appeal by Pan American Grain Co.

    Science.gov (United States)

    2010-08-05

    ... by Pan American Grain Co. AGENCY: National Oceanic and Atmospheric Administration (NOAA), Department..., closure of the decision record in an administrative appeal filed by Pan American Grain Co. (Pan American..., 2010, Pan American Grain Co. filed notice of an appeal with the Secretary of Commerce (Secretary...

  4. SPOTS4. Group data library and computer code, preparing ENDF/B-4 data for input to LEOPARD

    International Nuclear Information System (INIS)

    Kim, J.D.; Lee, J.T.

    1981-09-01

    The magnetic tape SPOTS4 contains in file 1 a data library to be used as input to the SPOTS4 program which is contained in file 2. The data library is based on ENDF/B-4 and consists of two parts in TEMPEST format (246 groups) and MUFT format (54 groups) respectively. From this library the SPOTS4 program produces a 172 + 54 group library for LEOPARD input. A copy of the magnetic tape is available from the IAEA Nuclear Data Section. (author)

  5. 76 FR 76711 - DCP Raptor Pipeline, LLC; Notice of Motion for Extension of Rate Case Filing Deadline

    Science.gov (United States)

    2011-12-08

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR09-32-003] DCP Raptor..., 2011, DCP Raptor Pipeline, LLC (Raptor) filed a request for an extension consistent with the Commission... pipelines to extend the cycle for such reviews from three to five years.\\1\\ Therefore, Raptor requests that...

  6. Performance of the Galley Parallel File System

    Science.gov (United States)

    Nieuwejaar, Nils; Kotz, David

    1996-01-01

    As the input/output (I/O) needs of parallel scientific applications increase, file systems for multiprocessors are being designed to provide applications with parallel access to multiple disks. Many parallel file systems present applications with a conventional Unix-like interface that allows the application to access multiple disks transparently. This interface conceals the parallism within the file system, which increases the ease of programmability, but makes it difficult or impossible for sophisticated programmers and libraries to use knowledge about their I/O needs to exploit that parallelism. Furthermore, most current parallel file systems are optimized for a different workload than they are being asked to support. We introduce Galley, a new parallel file system that is intended to efficiently support realistic parallel workloads. Initial experiments, reported in this paper, indicate that Galley is capable of providing high-performance 1/O to applications the applications that rely on them. In Section 3 we describe that access data in patterns that have been observed to be common.

  7. Optimized distributed systems achieve significant performance improvement on sorted merging of massive VCF files.

    Science.gov (United States)

    Sun, Xiaobo; Gao, Jingjing; Jin, Peng; Eng, Celeste; Burchard, Esteban G; Beaty, Terri H; Ruczinski, Ingo; Mathias, Rasika A; Barnes, Kathleen; Wang, Fusheng; Qin, Zhaohui S

    2018-06-01

    Sorted merging of genomic data is a common data operation necessary in many sequencing-based studies. It involves sorting and merging genomic data from different subjects by their genomic locations. In particular, merging a large number of variant call format (VCF) files is frequently required in large-scale whole-genome sequencing or whole-exome sequencing projects. Traditional single-machine based methods become increasingly inefficient when processing large numbers of files due to the excessive computation time and Input/Output bottleneck. Distributed systems and more recent cloud-based systems offer an attractive solution. However, carefully designed and optimized workflow patterns and execution plans (schemas) are required to take full advantage of the increased computing power while overcoming bottlenecks to achieve high performance. In this study, we custom-design optimized schemas for three Apache big data platforms, Hadoop (MapReduce), HBase, and Spark, to perform sorted merging of a large number of VCF files. These schemas all adopt the divide-and-conquer strategy to split the merging job into sequential phases/stages consisting of subtasks that are conquered in an ordered, parallel, and bottleneck-free way. In two illustrating examples, we test the performance of our schemas on merging multiple VCF files into either a single TPED or a single VCF file, which are benchmarked with the traditional single/parallel multiway-merge methods, message passing interface (MPI)-based high-performance computing (HPC) implementation, and the popular VCFTools. Our experiments suggest all three schemas either deliver a significant improvement in efficiency or render much better strong and weak scalabilities over traditional methods. Our findings provide generalized scalable schemas for performing sorted merging on genetics and genomics data using these Apache distributed systems.

  8. Creating and Viewing HTML Files with Python

    OpenAIRE

    William J. Turkel; Adam Crymble

    2012-01-01

    This lesson uses Python to create and view an HTML file. If you write programs that output HTML, you can use any browser to look at your results. This is especially convenient if your program is automatically creating hyperlinks or graphic entities like charts and diagrams. Here you will learn how to create HTML files with Python scripts, and how to use Python to automatically open an HTML file in Firefox.

  9. Methods and Algorithms for Detecting Objects in Video Files

    Directory of Open Access Journals (Sweden)

    Nguyen The Cuong

    2018-01-01

    Full Text Available Video files are files that store motion pictures and sounds like in real life. In today's world, the need for automated processing of information in video files is increasing. Automated processing of information has a wide range of application including office/home surveillance cameras, traffic control, sports applications, remote object detection, and others. In particular, detection and tracking of object movement in video file plays an important role. This article describes the methods of detecting objects in video files. Today, this problem in the field of computer vision is being studied worldwide.

  10. Shaping Ability of Reciproc, WaveOne GOLD, and HyFlex EDM Single-file Systems in Simulated S-shaped Canals.

    Science.gov (United States)

    Özyürek, Taha; Yılmaz, Koray; Uslu, Gülşah

    2017-05-01

    The aim of the present study was to compare the shaping ability of Reciproc (RPC; VDW, Munich, Germany), HyFlex EDM (HEDM; Coltene/Whaledent AG, Altstätten, Switzerland), and WaveOne GOLD (WOG; Dentsply Maillefer, Ballaigues, Switzerland) nickel-titanium (NiTi) files made of different NiTi alloys in S-shaped simulated canals. Sixty S-shaped canals in resin blocks were prepared to an apical size of 0.25 mm using RPC R25, WOG Primary, and HEDM OneFile (n = 20 canal/per group) systems. Composite images were made from the superimposition of pre- and postinstrumentation images. The amount of resin removed by each system was measured using a digital template and image analysis software in 22 different points. Canal aberrations were also recorded. Data were statistically analyzed using the Kruskal-Wallis and post hoc Dunn tests at the 5% level. NiTi file fracture was not observed during shaping of the simulated canals although a danger zone formation in 1 sample and a ledge in 1 sample were observed in the RPC group. There was no statistically significant difference between the WOG and HEDM groups' apical, medial, and coronal regions (P > .05). However, it was determined that the RPC group removed a statistically significantly higher amount of resin from all the canal regions when compared with the WOG and HEDM groups (P < .05). Within the limitation of the present study, it was determined that all of the tested NiTi files caused various levels of resin removal. However, WOG and HEDM NiTi files were found to cause a lower level of resin removal than RPC NiTi files. Copyright © 2017 American Association of Endodontists. All rights reserved.

  11. 78 FR 64488 - Combined Notice of Filings #1

    Science.gov (United States)

    2013-10-29

    ... Numbers: ER13-585-000. Applicants: New England Power Pool Participants Committee, ISO New England Inc... Pool, Inc. Description: Removal of NERCs Administration of Reliability-Grid Management Tools to be... qualifying facilities filings can be found at: http://www.ferc.gov/docs-filing/efiling/filing-req.pdf . For...

  12. 78 FR 19475 - Combined Notice of Filings #1

    Science.gov (United States)

    2013-04-01

    ... Wholesale Generator Status of Alta Wind X, LLC. Filed Date: 3/21/13. Accession Number: 20130321-5127...: Notice of Self-Certification of Exempt Wholesale Generator Status of Alta Wind XI, LLC. Filed Date: 3/21... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings 1 Take notice...

  13. 78 FR 62345 - Combined Notice of Filings #2

    Science.gov (United States)

    2013-10-18

    ... Generator Status of Miami Wind I LLC. Filed Date: 10/9/13. Accession Number: 20131009-5053. Comments Due: 5... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings 2 Take notice that the Commission received the following exempt wholesale generator filings: Docket Numbers: EG14-3...

  14. 75 FR 61733 - Combined Notice of Filings #1

    Science.gov (United States)

    2010-10-06

    ... MBR Tariff making the required change. Filed Date: 09/27/2010. Accession Number: 20100928-0206... Grove MBR Baseline to be effective 9/27/2010. Filed Date: 09/27/2010. Accession Number: 20100927-5227..., LLC. Description: Champion Energy Services, LLC submits tariff filing per 35.12: MBR application to be...

  15. 76 FR 64937 - Combined Notice of Filings #1

    Science.gov (United States)

    2011-10-19

    .... Description: Lockhart Power Company submits tariff filing per 35: Revisions to Lockhart MBR Tariff to be... Inc. Description: Alcoa Power Generating Inc. submits tariff filing per 35: APGI Revisions to MBR...: APM Revisions to MBR Tariff--Seller Category to be effective 10/12/ 2011. Filed Date: 10/11/2011...

  16. 76 FR 12353 - Combined Notice of Filings #2

    Science.gov (United States)

    2011-03-07

    ... PowerSecure Inc. at Washington, NC Walmart. Filed Date: 07/02/2010. Accession Number: 20100702-5029...: Self-Certification of PowerSecure Inc. at Laurinburg, NC Walmart. Filed Date: 07/02/2010. Accession...Secure, Inc. Description: Self-Certification of PowerSecure Inc. at Wilson, NC Walmart. Filed Date: 07/02...

  17. 37 CFR 401.16 - Electronic filing.

    Science.gov (United States)

    2010-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Electronic filing. 401.16 Section 401.16 Patents, Trademarks, and Copyrights ASSISTANT SECRETARY FOR TECHNOLOGY POLICY, DEPARTMENT... GOVERNMENT GRANTS, CONTRACTS, AND COOPERATIVE AGREEMENTS § 401.16 Electronic filing. Unless otherwise...

  18. Endodontic complications of root canal therapy performed by dental students with stainless-steel K-files and nickel-titanium hand files.

    Science.gov (United States)

    Pettiette, M T; Metzger, Z; Phillips, C; Trope, M

    1999-04-01

    Straightening of curved canals is one of the most common procedural errors in endodontic instrumentation. This problem is commonly encountered when dental students perform molar endodontics. The purpose of this study was to compare the effect of the type of instrument used by these students on the extent of straightening and on the incidence of other endodontic procedural errors. Nickel-titanium 0.02 taper hand files were compared with traditional stainless-steel 0.02 taper K-files. Sixty molar teeth comprised of maxillary and mandibular first and second molars were treated by senior dental students. Instrumentation was with either nickel-titanium hand files or stainless-steel K-files. Preoperative and postoperative radiographs of each tooth were taken using an XCP precision instrument with a customized bite block to ensure accurate reproduction of radiographic angulation. The radiographs were scanned and the images stored as TIFF files. By superimposing tracings from the preoperative over the postoperative radiographs, the degree of deviation of the apical third of the root canal filling from the original canal was measured. The presence of other errors, such as strip perforation and instrument breakage, was established by examining the radiographs. In curved canals instrumented by stainless-steel K-files, the average deviation of the apical third of the canals was 14.44 degrees (+/- 10.33 degrees). The deviation was significantly reduced when nickel-titanium hand files were used to an average of 4.39 degrees (+/- 4.53 degrees). The incidence of other procedural errors was also significantly reduced by the use of nickel-titanium hand files.

  19. Cone-beam computed tomography analysis of curved root canals after mechanical preparation with three nickel-titanium rotary instruments

    Science.gov (United States)

    Elsherief, Samia M.; Zayet, Mohamed K.; Hamouda, Ibrahim M.

    2013-01-01

    Cone beam computed tomography is a 3-dimensional high resolution imaging method. The purpose of this study was to compare the effects of 3 different NiTi rotary instruments used to prepare curved root canals on the final shape of the curved canals and total amount of root canal transportation by using cone-beam computed tomography. A total of 81 mesial root canals from 42 extracted human mandibular molars, with a curvature ranging from 15 to 45 degrees, were selected. Canals were randomly divided into 3 groups of 27 each. After preparation with Protaper, Revo-S and Hero Shaper, the amount of transportation and centering ability that occurred were assessed by using cone beam computed tomography. Utilizing pre- and post-instrumentation radiographs, straightening of the canal curvatures was determined with a computer image analysis program. Canals were metrically assessed for changes (surface area, changes in curvature and transportation) during canal preparation by using software SimPlant; instrument failures were also recorded. Mean total widths and outer and inner width measurements were determined on each central canal path and differences were statistically analyzed. The results showed that all instruments maintained the original canal curvature well with no significant differences between the different files (P = 0.226). During preparation there was failure of only one file (the protaper group). In conclusion, under the conditions of this study, all instruments maintained the original canal curvature well and were safe to use. Areas of uninstrumented root canal wall were left in all regions using the various systems. PMID:23885273

  20. The design and development of GRASS file reservation system

    International Nuclear Information System (INIS)

    Huang Qiulan; Zhu Suijiang; Cheng Yaodong; Chen Gang

    2010-01-01

    GFRS (GRASS File Reservation System) is designed to improve the file access performance of GRASS (Grid-enabled Advanced Storage System) which is a Hierarchical Storage Management (HSM) system developed at Computing Center, Institute of High Energy Physics. GRASS can provide massive storage management and data migration, but the data migration policy is simply based factors such as pool water level, the intervals for migration and so on, so it is short of precise control over files. As for that, we design GFRS to implement user-based file reservation which is to reserve and keep the required files on disks for High Energy physicists. CFRS can improve file access speed for users by avoiding migrating frequently accessed files to tapes. In this paper we first give a brief introduction of GRASS system and then detailed architecture and implementation of GFRS. Experiments results from GFRS have shown good performance and a simple analysis is made based on it. (authors)