WorldWideScience

Sample records for preoperative y-90 microsphere

  1. Preoperative Y-90 microsphere selective internal radiation treatment for tumor downsizing and future liver remnant recruitment: a novel approach to improving the safety of major hepatic resections.

    Science.gov (United States)

    Gulec, Seza A; Pennington, Kenneth; Hall, Michael; Fong, Yuman

    2009-01-08

    Extended liver resections are being performed more liberally than ever. The extent of resection of liver metastases, however, is restricted by the volume of the future liver remnant (FLR). An intervention that would both accomplish tumor control and induce compensatory hypertrophy, with good patient tolerability, could improve clinical outcomes. A 53-year-old woman with a history of cervical cancer presented with a large liver mass. Subsequent biopsy indicated poorly differentiated carcinoma with necrosis suggestive of squamous cell origin. A decision was made to proceed with pre-operative chemotherapy and Y-90 microsphere SIRT with the intent to obtain systemic control over the disease, downsize the hepatic lesion, and improve the FLR. A surgical exploration was performed six months after the first SIRT (three months after the second). There was no extrahepatic disease. The tumor was found to be significantly decreased in size with central and peripheral scarring. The left lobe was satisfactorily hypertrophied. A formal right hepatic lobectomy was performed with macroscopic negative margins. Selective internal radiation treatment (SIRT) with yttrium-90 (Y-90) microspheres has emerged as an effective liver-directed therapy with a favorable therapeutic ratio. We present this case report to suggest that the portal vein radiation dose can be substantially increased with the intent of inducing portal/periportal fibrosis. Such a therapeutic manipulation in lobar Y-90 microsphere treatment could accomplish the end points of PVE with avoidance of the concern regarding tumor progression.

  2. Y-90 microsphere therapy: prevention of adverse events.

    Science.gov (United States)

    Schultz, Cheryl C; Campbell, Janice; Bakalyar, Donovan; Beauvais, Michele; Feng, Wenzheng; Savin, Michael

    2009-08-01

    Thirty-three (33) events that were inconsistent with intended treatment for 471 Y-90 microsphere deliveries were analyzed from 2001 to 2007. Each occurrence was categorized, based on root-cause analysis, as a device/product defect and/or operator error event. Events were further categorized, if there was an adverse outcome, as spill/leak, termination, recatheterization, dose deviation, and/or a regulatory medical event. Of 264 Y-90 Therasphere (MDS Nordion, Ottawa, Ontario, Canada) treatments, 15 events were reported (5.7%). Of 207 Y-90 SIR-Spheres (Sirtex, Wilmington, MA) treatments, 18 events were reported (8.7%). Twenty-five (25) of 33 events (76%) were device/product defects: 73% for Therasphere (11 of 15) and 78% for SIR-Spheres (14 of 18). There were 31 adverse outcomes associated with 33 events: 15 were leaks and/or spills, 9 resulted in termination of the dose administration, 3 resulted in recatheterization for dose compensation, 2 were dose deviations (doses differing from the prescribed between 10% and 20%), and 2 were reported as regulatory medical events. Fifty-five (55) corrective actions were taken: 39 (71%) were related to the manufacturer and 16 (29%) were hospital based. This process of analyzing each event and measuring our outcomes has been effective at minimizing adverse events and improving patient safety.

  3. Pilot trial of Y-90 glass microspheres in the treatment of primary hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Houle, S.; Yip, T.C.K.; Shepherd, F.A.; Rotstein, L.E.; Theis, B.; Cawthorn, R.; Barnes, K.

    1987-01-01

    A pilot trial is currently under way at our institution to determine the potential of new Y-90 glass microspheres (Theraspheres, Theragenics Corp., Atlanta) for the treatment of primary hepatocellular carcinoma. The Y-90 microspheres are injected through a percutaneous hepatic artery catheter positioned angiographically. The injection is facilitated by a new delivery system. Prior to the injection of the Y-90 microspheres, the presence of shunting is assessed by injecting Tc-99m human albumin microspheres (HAM) via the hepatic artery catheter. Bremsstrahlung scans done after injection demonstrate the distribution the Y-90 microspheres within the liver and the lack of extrahepatic activity. In the first group of patients treated, no significant toxicity was demonstrated for absorbed doses between 5,000 and 10,000 rad to the liver, and up to 20,000 rad to the tumor itself

  4. Y-90 microspheres in the treatment of unresectable hepatocellularcarcinoma

    International Nuclear Information System (INIS)

    Al-Kalbani, A.; Kamel, Y.

    2008-01-01

    A small percentage of patients with hepatocellular carcinoma (HCC) arecandidates for curative treatment in form of resection or transplantation.There are different treatment options for unresectable HCC-like localablative therapies and recently systemic therapy with Sorafenib. All of thesehave variable response rate and had been proven to improve survival. In thelast few years, there is a growing interest in TheraSphere radioembolization.It consists of yttrium (Y-90) embedded into nonbiodegradeable glassmicrospheres. It is selectively administered by intraarterial hepaticinjection giving high doses of radiation to the tumor and sparing the liverparenchyma. It has been shown to improve survival and used as a bridge totransplantation and to downstage tumors for resection. Therasphere seems tohave favorable safety profile and has been used in patients with portal veinthrombosis with successful outcome. (author)

  5. Process improvement for the safe delivery of multidisciplinary-executed treatments-A case in Y-90 microspheres therapy.

    Science.gov (United States)

    Cai, Bin; Altman, Michael B; Garcia-Ramirez, Jose; LaBrash, Jason; Goddu, S Murty; Mutic, Sasa; Parikh, Parag J; Olsen, Jeffrey R; Saad, Nael; Zoberi, Jacqueline E

    To develop a safe and robust workflow for yttrium-90 (Y-90) radioembolization procedures in a multidisciplinary team environment. A generalized Define-Measure-Analyze-Improve-Control (DMAIC)-based approach to process improvement was applied to a Y-90 radioembolization workflow. In the first DMAIC cycle, events with the Y-90 workflow were defined and analyzed. To improve the workflow, a web-based interactive electronic white board (EWB) system was adopted as the central communication platform and information processing hub. The EWB-based Y-90 workflow then underwent a second DMAIC cycle. Out of 245 treatments, three misses that went undetected until treatment initiation were recorded over a period of 21 months, and root-cause-analysis was performed to determine causes of each incident and opportunities for improvement. The EWB-based Y-90 process was further improved via new rules to define reliable sources of information as inputs into the planning process, as well as new check points to ensure this information was communicated correctly throughout the process flow. After implementation of the revised EWB-based Y-90 workflow, after two DMAIC-like cycles, there were zero misses out of 153 patient treatments in 1 year. The DMAIC-based approach adopted here allowed the iterative development of a robust workflow to achieve an adaptable, event-minimizing planning process despite a complex setting which requires the participation of multiple teams for Y-90 microspheres therapy. Implementation of such a workflow using the EWB or similar platform with a DMAIC-based process improvement approach could be expanded to other treatment procedures, especially those requiring multidisciplinary management. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  6. Comparison of the stability of Y-90-, Lu-177- and Ga-68- labeled human serum albumin microspheres (DOTA-HSAM)

    Energy Technology Data Exchange (ETDEWEB)

    Wunderlich, Gerd [Department of Nuclear Medicine, University Hospital, 01307 Dresden (Germany); Schiller, Eik, E-mail: eisc@rotop-pharmaka.d [ROTOP Pharmaka AG, 01454 Radeberg (Germany); Bergmann, Ralf; Pietzsch, Hans-Juergen [Forschungszentrum Dresden-Rossendorf, Institute of Radiopharmacy, P.O. Box 510119, 01314 Dresden (Germany)

    2010-11-15

    Introduction: Microparticles derived from denatured human serum albumin (DOTA-derivatized human serum albumin microspheres, or DOTA-HSAM) are attractive carriers of radionuclides for both therapeutic and diagnostic purposes. In this article, we describe a labeling procedure for diagnostic (Ga-68) and therapeutic (Y-90, Lu-177) radionuclides and report on the results of stability studies of these products. Methods: DOTA-HSAM was labeled in 0.5 M ammonium acetate buffer, pH 5.0, containing 0.02 mg/ml detergent. After adding the radionuclide, the mixture was shaken for 15 min at 90{sup o}C. Labeling yields and in vitro stability were determined by thin-layer chromatography. For determination of the in vivo stability of Ga-68 and Y-90 DOTA-HSAM, the particles were injected intravenously in Wistar rats. Results: Labeling yields up to 95% in the case of Ga-68 and Lu-177 were achieved. Ga-68-labeled DOTA-HSAM showed high in vitro and in vivo stability. The amount of particle-bound radioactivity of Lu-177 DOTA-HSAM declines slowly in a linear manner to approximately 72% after 13 days. For Y-90, the labeling yield decreased with increasing radioactivity level. We presume radiolysis as the reason for these findings. Conclusion: The labeling of DOTA-HSAM with different radionuclides is easy to perform. The radiation-induced cleavage of the labeled chelator together with the rather short half-life of radioactivity fixation in vivo (3.7 days) is, in our opinion, opposed to therapeutic applications of DOTA-HSAM. On the other hand, the high stability of Ga-68 DOTA-HSAM makes them an attractive candidate for the measurement of regional perfusion by PET.

  7. Comparison of the stability of Y-90-, Lu-177- and Ga-68- labeled human serum albumin microspheres (DOTA-HSAM)

    International Nuclear Information System (INIS)

    Wunderlich, Gerd; Schiller, Eik; Bergmann, Ralf; Pietzsch, Hans-Juergen

    2010-01-01

    Introduction: Microparticles derived from denatured human serum albumin (DOTA-derivatized human serum albumin microspheres, or DOTA-HSAM) are attractive carriers of radionuclides for both therapeutic and diagnostic purposes. In this article, we describe a labeling procedure for diagnostic (Ga-68) and therapeutic (Y-90, Lu-177) radionuclides and report on the results of stability studies of these products. Methods: DOTA-HSAM was labeled in 0.5 M ammonium acetate buffer, pH 5.0, containing 0.02 mg/ml detergent. After adding the radionuclide, the mixture was shaken for 15 min at 90 o C. Labeling yields and in vitro stability were determined by thin-layer chromatography. For determination of the in vivo stability of Ga-68 and Y-90 DOTA-HSAM, the particles were injected intravenously in Wistar rats. Results: Labeling yields up to 95% in the case of Ga-68 and Lu-177 were achieved. Ga-68-labeled DOTA-HSAM showed high in vitro and in vivo stability. The amount of particle-bound radioactivity of Lu-177 DOTA-HSAM declines slowly in a linear manner to approximately 72% after 13 days. For Y-90, the labeling yield decreased with increasing radioactivity level. We presume radiolysis as the reason for these findings. Conclusion: The labeling of DOTA-HSAM with different radionuclides is easy to perform. The radiation-induced cleavage of the labeled chelator together with the rather short half-life of radioactivity fixation in vivo (3.7 days) is, in our opinion, opposed to therapeutic applications of DOTA-HSAM. On the other hand, the high stability of Ga-68 DOTA-HSAM makes them an attractive candidate for the measurement of regional perfusion by PET.

  8. SU-D-201-05: Phantom Study to Determine Optimal PET Reconstruction Parameters for PET/MR Imaging of Y-90 Microspheres Following Radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Maughan, N [Washington University in Saint Louis, Saint Louis, MO (United States); Conti, M [Siemens Healthcare Molecular Imaging, Knoxville, TN (United States); Parikh, P [Washington Univ. School of Medicine, Saint Louis, MO (United States); Faul, D [Siemens Healthcare, New York, NY (United States); Laforest, R [Washington University School of Medicine, Saint Louis, MO (United States)

    2015-06-15

    Purpose: Imaging Y-90 microspheres with PET/MRI following hepatic radioembolization has the potential for predicting treatment outcome and, in turn, improving patient care. The positron decay branching ratio, however, is very small (32 ppm), yielding images with poor statistics even when therapy doses are used. Our purpose is to find PET reconstruction parameters that maximize the PET recovery coefficients and minimize noise. Methods: An initial 7.5 GBq of Y-90 chloride solution was used to fill an ACR phantom for measurements with a PET/MRI scanner (Siemens Biograph mMR). Four hot cylinders and a warm background activity volume of the phantom were filled with a 10:1 ratio. Phantom attenuation maps were derived from scaled CT images of the phantom and included the MR phased array coil. The phantom was imaged at six time points between 7.5–1.0 GBq total activity over a period of eight days. PET images were reconstructed via OP-OSEM with 21 subsets and varying iteration number (1–5), post-reconstruction filter size (5–10 mm), and either absolute or relative scatter correction. Recovery coefficients, SNR, and noise were measured as well as total activity in the phantom. Results: For the 120 different reconstructions, recovery coefficients ranged from 0.1–0.6 and improved with increasing iteration number and reduced post-reconstruction filter size. SNR, however, improved substantially with lower iteration numbers and larger post-reconstruction filters. From the phantom data, we found that performing 2 iterations, 21 subsets, and applying a 5 mm Gaussian post-reconstruction filter provided optimal recovery coefficients at a moderate noise level for a wide range of activity levels. Conclusion: The choice of reconstruction parameters for Y-90 PET images greatly influences both the accuracy of measurements and image quality. We have found reconstruction parameters that provide optimal recovery coefficients with minimized noise. Future work will include the effects

  9. TU-FG-201-12: Designing a Risk-Based Quality Assurance Program for a Newly Implemented Y-90 Microspheres Procedure

    International Nuclear Information System (INIS)

    Vile, D; Zhang, L; Cuttino, L; Kim, S; Palta, J

    2016-01-01

    Purpose: To create a quality assurance program based upon a risk-based assessment of a newly implemented SirSpheres Y-90 procedure. Methods: A process map was created for a newly implemented SirSpheres procedure at a community hospital. The process map documented each step of this collaborative procedure, as well as the roles and responsibilities of each member. From the process map, different potential failure modes were determined as well as any current controls in place. From this list, a full failure mode and effects analysis (FMEA) was performed by grading each failure mode’s likelihood of occurrence, likelihood of detection, and potential severity. These numbers were then multiplied to compute the risk priority number (RPN) for each potential failure mode. Failure modes were then ranked based on their RPN. Additional controls were then added, with failure modes corresponding to the highest RPNs taking priority. Results: A process map was created that succinctly outlined each step in the SirSpheres procedure in its current implementation. From this, 72 potential failure modes were identified and ranked according to their associated RPN. Quality assurance controls and safety barriers were then added for failure modes associated with the highest risk being addressed first. Conclusion: A quality assurance program was created from a risk-based assessment of the SirSpheres process. Process mapping and FMEA were effective in identifying potential high-risk failure modes for this new procedure, which were prioritized for new quality assurance controls. TG 100 recommends the fault tree analysis methodology to design a comprehensive and effective QC/QM program, yet we found that by simply introducing additional safety barriers to address high RPN failure modes makes the whole process simpler and safer.

  10. TU-FG-201-12: Designing a Risk-Based Quality Assurance Program for a Newly Implemented Y-90 Microspheres Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Vile, D; Zhang, L; Cuttino, L; Kim, S; Palta, J [Virginia Commonwealth University, Richmond, VA (United States)

    2016-06-15

    Purpose: To create a quality assurance program based upon a risk-based assessment of a newly implemented SirSpheres Y-90 procedure. Methods: A process map was created for a newly implemented SirSpheres procedure at a community hospital. The process map documented each step of this collaborative procedure, as well as the roles and responsibilities of each member. From the process map, different potential failure modes were determined as well as any current controls in place. From this list, a full failure mode and effects analysis (FMEA) was performed by grading each failure mode’s likelihood of occurrence, likelihood of detection, and potential severity. These numbers were then multiplied to compute the risk priority number (RPN) for each potential failure mode. Failure modes were then ranked based on their RPN. Additional controls were then added, with failure modes corresponding to the highest RPNs taking priority. Results: A process map was created that succinctly outlined each step in the SirSpheres procedure in its current implementation. From this, 72 potential failure modes were identified and ranked according to their associated RPN. Quality assurance controls and safety barriers were then added for failure modes associated with the highest risk being addressed first. Conclusion: A quality assurance program was created from a risk-based assessment of the SirSpheres process. Process mapping and FMEA were effective in identifying potential high-risk failure modes for this new procedure, which were prioritized for new quality assurance controls. TG 100 recommends the fault tree analysis methodology to design a comprehensive and effective QC/QM program, yet we found that by simply introducing additional safety barriers to address high RPN failure modes makes the whole process simpler and safer.

  11. Safety and efficacy of Y-90 microsphere treatment in patients with primary and metastatic liver cancer: The tumor selectivity of the treatment as a function of tumor to liver flow ratio

    Directory of Open Access Journals (Sweden)

    Dezarn William A

    2007-03-01

    Full Text Available Abstract Background Treatment records and follow-up data on 40 patients with primary and metastatic liver malignancies who underwent a single whole-liver treatment with Y-90 resin microspheres (SIR-Spheres® Sirtex Medical, Lake Forest, IL were retrospectively reviewed. The objective of the study was to evaluate the anatomic and physiologic determinants of radiation dose distribution, and the dose response of tumor and liver toxicity in patients with liver malignancies who underwent hepatic arterial Y-90 resin microsphere treatment. Methods Liver and tumor volume calculations were performed on pre-treatment CT scans. Fractional tumor and liver flow characteristics and lung shunt fractions were determined using hepatic arterial Tc-99m MAA imaging. Absorbed dose calculations were performed using the MIRD equations. Liver toxicity was assessed clinically and by liver function tests. Tumor response to therapy was assessed by CT and/or tumor markers. Results Of the 40 patients, 5 had hepatocellular cancer (HCC, and 35 had metastatic liver tumors (15 colorectal cancer, 10 neuroendocrine tumors, 4 breast cancer, 2 lung cancer, 1 ovarian cancer, 1 endometrial cancer, and 2 unknown primary adenocarcinoma. All patients were treated in a salvage setting with a 3 to 80 week follow-up (mean: 19 weeks. Tumor volumes ranged from 15.0 to 984.2 cc (mean: 294.9 cc and tumor to normal liver uptake ratios ranged from 2.8 to 15.4 (mean: 5.4. Average administered activity was 1.2 GBq (0.4 to 2.4 GBq. Liver absorbed doses ranged from 0.7 to 99.5 Gy (mean: 17.2 Gy. Tumor absorbed doses ranged from 40.1 to 494.8 Gy (mean: 121.5 Gy. None of the patients had clinical venoocclusive disease or therapy-induced liver failure. Seven patients (17.5 % had transient and 7 patients (17.5 % had persistent LFT abnormalities. There were 27 (67.5% responders (complete response, partial response, and stable disease. Tumor response correlated with higher tumor flow ratio as measured by

  12. Trisacryl Gelatin Microspheres Versus Polyvinyl Alcohol Particles in the Preoperative Embolization of Bone Neoplasms

    International Nuclear Information System (INIS)

    Basile, Antonio; Rand, Thomas; Lomoschitz, Fritz; Toma, Cyril; Lupattelli, Tommaso; Kettenbach, Joachim; Lammer, Johannes

    2004-01-01

    The aim of this study was to compare the efficacy of trisacryl gelatin microspheres versus polyvinyl alcohol particles (PVA) in the preoperative embolization of bone neoplasms, on the basis of intraoperative blood loss quantified by the differences in preoperative and postoperative hematic levels of hemoglobin, hematocrit and erythrocytes count. From January 1997 to December 2002, preoperative embolization of bone tumors (either primary or secondary) was carried out in 49 patients (age range 12/78), 20 of whom were treated with trysacril gelatin microspheres (group A) and 29 with PVA particles (group B). The delay between embolization and surgery ranged from 1 to 13 days in group A and 1 to 4 days in group B. As used in international protocols, we considered hematic levels of hemoglobin, hematocrit and erythrocytes count for the measurement of intraoperative blood loss then the differences in pre- and postoperative levels were used as statistical comparative parameters. We compared the values of patients treated with embospheres (n = 10) and PVA (n = 18) alone, and patients treated with (group A = 10; group B = 11) versus patients treated without other additional embolic materials in each group (group A = 10; group B = 18). According to the Student's t-test (p < 0.05), the difference of hematic parameters between patients treated by embospheres and PVA alone were significant; otherwise there was no significant difference between patients treated with only one embolic material (embospheres and PVA) versus those treated with other additional embolic agents in each group. The patients treated with microspheres had a minor quantification of intraoperative blood loss compared to those who received PVA particles. Furthermore, they had a minor increase of bleeding related to the delay time between embolization and surgery. The use of additional embolic material did not improve the efficacy of the procedure in either group of patients

  13. Y-90 microshperes in the treatment of unresectable hepatocellular carcinoma.

    Science.gov (United States)

    Al-Kalbani, Abdullah; Kamel, Yasser

    2008-04-01

    A small percentage of patients with hepatocellular carcinoma (HCC) are candidates for curative treatment in form of resection or transplantation. There are different treatment options for unresectable HCC-like local ablative therapies and recently systemic therapy with Sorafenib. All of these have variable response rate and had been proven to improve survival. In the last few years, there is a growing interest in TheraSphere radioembolization. It consists of yttrium90 (Y-90) embedded into nonbiodegradable glass microspheres. It is selectively administered by intraarterial hepatic injection giving high doses of radiation to the tumor and sparing the liver parenchyma. It has been shown to improve survival and used as a bridge to transplantation and to downstage tumors for resection. Therasphere seems to have favorable safety profile and has been used in patients with portal vein thrombosis with successful outcome.

  14. Radioactive impurities in radiopharmaceuticals with Y-90. Consequences for waste disposal; Radioaktive Verunreinigungen in Radiopharmazeutika mit Y-90. Konsequenzen fuer die Entsorgung von Reststoffen

    Energy Technology Data Exchange (ETDEWEB)

    Wanke, C.; Solle, A.; Geworski, L. [Medizinische Hochschule Hannover (Germany). Stabsstelle Strahlenschutz und Abt. Medizinische Physik

    2016-07-01

    Y-90 plays an important role in nuclear medicine and is of particular interest in radiation synovectomy (RSO) and in Selective internal radiation therapy (SIRT). Longer-lived impurities were investigated in a pharmaceutical used in RSO and in glass microspheres applied for SIRT. For this, measurements were carried out to identify gamma-emitting impurities. Especially in the late measurements, after decay of Y-90, impurities such as Y-88 and Y-91, Zn-65, Eu-152, Gd-153, Tb-160 und Yb-169 were identified, which accounted for less than 0,01 % of the total radioactivity at the calibration date, so that all pharmaceutical requirements were met. The impurities, however, have to be taken into account in waste management and clearance. Assuming typical masses, waste from RSO can undergo unrestricted clearance based on the clearance values tabulated in the German Radiation Protection Ordinance, provided sufficient decay storage. For waste from SIRT with glass microspheres, however, other clearance or disposal options have to be found.

  15. Hanford isotope project strategic business analysis yttrium-90 (Y-90)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-10-01

    The purpose of this analysis is to address the short-term direction for the Hanford yttrium-90 (Y-90) project. Hanford is the sole DOE producer of Y-90, and is the largest repository for its source in this country. The production of Y-90 is part of the DOE Isotope Production and Distribution (IP and D) mission. The Y-90 is ``milked`` from strontium-90 (Sr-90), a byproduct of the previous Hanford missions. The use of Sr-90 to produce Y-90 could help reduce the amount of waste material processed and the related costs incurred by the clean-up mission, while providing medical and economic benefits. The cost of producing Y-90 is being subsidized by DOE-IP and D due to its use for research, and resultant low production level. It is possible that the sales of Y-90 could produce full cost recovery within two to three years, at two curies per week. Preliminary projections place the demand at between 20,000 and 50,000 curies per year within the next ten years, assuming FDA approval of one or more of the current therapies now in clinical trials. This level of production would incentivize private firms to commercialize the operation, and allow the government to recover some of its sunk costs. There are a number of potential barriers to the success of the Y-90 project, outside the control of the Hanford Site. The key issues include: efficacy, Food and Drug Administration (FDA) approval and medical community acceptance. There are at least three other sources for Y-90 available to the US users, but they appear to have limited resources to produce the isotope. Several companies have communicated interest in entering into agreements with Hanford for the processing and distribution of Y-90, including some of the major pharmaceutical firms in this country.

  16. Hanford isotope project strategic business analysis yttrium-90 (Y-90)

    International Nuclear Information System (INIS)

    1995-10-01

    The purpose of this analysis is to address the short-term direction for the Hanford yttrium-90 (Y-90) project. Hanford is the sole DOE producer of Y-90, and is the largest repository for its source in this country. The production of Y-90 is part of the DOE Isotope Production and Distribution (IP and D) mission. The Y-90 is ''milked'' from strontium-90 (Sr-90), a byproduct of the previous Hanford missions. The use of Sr-90 to produce Y-90 could help reduce the amount of waste material processed and the related costs incurred by the clean-up mission, while providing medical and economic benefits. The cost of producing Y-90 is being subsidized by DOE-IP and D due to its use for research, and resultant low production level. It is possible that the sales of Y-90 could produce full cost recovery within two to three years, at two curies per week. Preliminary projections place the demand at between 20,000 and 50,000 curies per year within the next ten years, assuming FDA approval of one or more of the current therapies now in clinical trials. This level of production would incentivize private firms to commercialize the operation, and allow the government to recover some of its sunk costs. There are a number of potential barriers to the success of the Y-90 project, outside the control of the Hanford Site. The key issues include: efficacy, Food and Drug Administration (FDA) approval and medical community acceptance. There are at least three other sources for Y-90 available to the US users, but they appear to have limited resources to produce the isotope. Several companies have communicated interest in entering into agreements with Hanford for the processing and distribution of Y-90, including some of the major pharmaceutical firms in this country

  17. A retrospective review of Y90 synovectomy in Auckland

    International Nuclear Information System (INIS)

    Stamp, L.

    2000-01-01

    Full text: A retrospective review of Yttrium 90 synovectomies carried out from June 1997 to February 1999 in Auckland Hospital to determine outcome from the procedure. Methods: Patients were sent a questionnaire for each treated knee The principal outcome measures assessed in the month prior and the 6 months after the Y90 were pain, swelling, walking distance and overall disability score. Referring doctors were sent a questionnaire to provide information on duration of synovitis and treatment. Outcomes measured were presence of effusion 6 months after the Y90, requirement for intra-articular steroid in the 12 months prior to and after the yttrium and change of therapy due lo ongoing symptoms in the treated knee. Results: 29 patients and 40 knees had Y90 during the study period 86% patients with 87.5% knees responded. Referring doctors for 86% patients accounting for 87.5% knees responded. The procedure was well tolerated with the majority of patients reporting nil-mild discomfort during and in the 24 hours after Y90. 86% knees treated reported improvement with a reduction in pain and swelling Patient global assessment reduced from 3.8 to 2.0 while physician global assessment reduced from 3.9 to 3.0. There was an improvement in walking distance 6 months after Y90 with the number of knees able to walk >1km increasing from 2 to 17 14 of 25 patients required a change in treatment because of ongoing problems in the treated knee and one patient has undergone knee joint replacement One further patient is waiting knee joint replacement The need for intra-articular steroid was reduced with 83%, knees having an average of 2.4 steroid injections in the 12 months prior to Y90 compared to 38% knees having an average of 0.7 steroid injections in the 12 months after Y90. Of the 30 knees reporting Improvement 24 knees are at least 12 months post Y90. Of these 50% were Improved at 12 months. As a result of this audit we continue to offer this procedure in the Auckland area, and

  18. Country report: Thailand. Development of Sr-90/ Y-90 Generator and Development of Radiopharmaceuticals Using Y-90

    International Nuclear Information System (INIS)

    Nipavan, Poramatikul

    2010-01-01

    The research project has been conducted at Thailand Institute of Nuclear Technology in accordance to the 1st RCM plan during the IAEA meeting in Warsaw. The objectives of the project include the following 5 specific aims: 1. Development of Sr-90/Y-90 ion-exchange chromatography generator 2. Development of Sr-90/Y-90 extraction chromatography generator 3. Development of quality control technique 4. Development of herapeutic radiopharmaceuticals Y-90 particulates/colloids 5. Development of Re-188 DMSA–bis-phosphonates Currently we have achieved specific aims 1 to 3. The specific aims 4 and 5 are during investigation. For specific aim 4, we are during the process to extract high purity 90 Y from 90 Sr/ 90 Y generator that will yield the starting 90 Y for the production of Y-90 particulates and colloids. For the 5 th specific aim, we are on hold to receive the starting agent, bis- Phosphonates, from Dr. Blower group. Therefore, this progress report will cover our work focusing on specific aims 1 to 3

  19. Country report: Thailand. Development of Sr-90/ Y-90 Generator and Development of Radiopharmaceuticals Using Y-90

    Energy Technology Data Exchange (ETDEWEB)

    Nipavan, Poramatikul [Nuclear Research and Development Group, Thailand Institute of Nuclear Technology (Public Organization), Bangkok (Thailand)

    2010-07-01

    The research project has been conducted at Thailand Institute of Nuclear Technology in accordance to the 1st RCM plan during the IAEA meeting in Warsaw. The objectives of the project include the following 5 specific aims: 1. Development of Sr-90/Y-90 ion-exchange chromatography generator 2. Development of Sr-90/Y-90 extraction chromatography generator 3. Development of quality control technique 4. Development of herapeutic radiopharmaceuticals Y-90 particulates/colloids 5. Development of Re-188 DMSA–bis-phosphonates Currently we have achieved specific aims 1 to 3. The specific aims 4 and 5 are during investigation. For specific aim 4, we are during the process to extract high purity {sup 90}Y from {sup 90}Sr/{sup 90}Y generator that will yield the starting {sup 90}Y for the production of Y-90 particulates and colloids. For the 5{sup th} specific aim, we are on hold to receive the starting agent, bis- Phosphonates, from Dr. Blower group. Therefore, this progress report will cover our work focusing on specific aims 1 to 3.

  20. A PET reconstruction formulation that enforces non-negativity in projection space for bias reduction in Y-90 imaging

    Science.gov (United States)

    Lim, Hongki; Dewaraja, Yuni K.; Fessler, Jeffrey A.

    2018-02-01

    Most existing PET image reconstruction methods impose a nonnegativity constraint in the image domain that is natural physically, but can lead to biased reconstructions. This bias is particularly problematic for Y-90 PET because of the low probability positron production and high random coincidence fraction. This paper investigates a new PET reconstruction formulation that enforces nonnegativity of the projections instead of the voxel values. This formulation allows some negative voxel values, thereby potentially reducing bias. Unlike the previously reported NEG-ML approach that modifies the Poisson log-likelihood to allow negative values, the new formulation retains the classical Poisson statistical model. To relax the non-negativity constraint embedded in the standard methods for PET reconstruction, we used an alternating direction method of multipliers (ADMM). Because choice of ADMM parameters can greatly influence convergence rate, we applied an automatic parameter selection method to improve the convergence speed. We investigated the methods using lung to liver slices of XCAT phantom. We simulated low true coincidence count-rates with high random fractions corresponding to the typical values from patient imaging in Y-90 microsphere radioembolization. We compared our new methods with standard reconstruction algorithms and NEG-ML and a regularized version thereof. Both our new method and NEG-ML allow more accurate quantification in all volumes of interest while yielding lower noise than the standard method. The performance of NEG-ML can degrade when its user-defined parameter is tuned poorly, while the proposed algorithm is robust to any count level without requiring parameter tuning.

  1. Quantitative measurement of Y90 brehmmstrahlung images after of Y90 Sir-Spheres implantation to assess lung shunting

    International Nuclear Information System (INIS)

    Forwood, Nicholas J.; Pocock, Nicholas; Shin, Jane; Young, Andy M; Szeto, Edwin R.

    2009-01-01

    Full text: Background: In clinical practice the dose of Y 9 0 Sir-Spheres is calculated using a pre injection of Tc 9 9 m MAA. There is however a potential difference due to the different properties of Tc 9 9 m MAA and Y 9 0 Sir-Spheres. We assessed the concordance of lung shunting of Y 9 0 Sir-Spheres estimated using Y 9 0 Bremsstrahlung imaging, compared to shunting assessed using Tc 9 9 m MAA. Methods: 15 Patients were evaluated using 150-200 MBq of Tc 9 9 m MAA injected into the hepatic artery under angiographic guidance. Whole body images were acquired using a LEAP collimator (window of 140 kEv+/-10%). The patients were subsequently treated with Y 9 0 Sir-Spheres. After microspheres injection, whole body brehmsstrahlung images were acquired using a medium energy collimator (window settings of 75 kEv +/- 20%). Tc 9 9 m MAA images were paired with their corresponding bremsstrahlung image and lung shunting in the stu ides calculated simultaneously. Each paired dataset was analyzed by 5 operators. Results: The mean lung shunting for Tc 9 9 m MAA acquisition was 3.32% (SD 2.03) which was significantly lower than the lung shunting using the Y 9 0 acquisitions: mean 16.19% (SD of 6.43). The Pearson coefficient was r = 0.62 (p 9 0 Sir-Spheres bremsstrahlung imaging is higher than that calculated by Tc 9 9 m MAA imaging. The relationship is not sufficiently strong to use bremsstahlung imaging to retrospectively quantify the lung-to-liver shunting as indicated using Tc 9 9 M AA. Further studies are underway to assess the reliability of Tc 9 9 m MAA lung uptake calculations in determining the dose of Y 9 0 Sir-Spheres.

  2. Yttrium-90 Selective Internal Radiation Therapy with Glass Microspheres for Hepatocellular Carcinoma: Current and Updated Literature Review

    International Nuclear Information System (INIS)

    Lee, Edward Wolfgang; Alanis, Lourdes; Cho, Sung-Ki; Saab, Sammy

    2016-01-01

    Hepatocellular carcinoma is the most common primary liver cancer and it represents the majority of cancer-related deaths in the world. More than 70% of patients present at an advanced stage, beyond potentially curative options. Ytrrium-90 selective internal radiation therapy (Y90-SIRT) with glass microspheres is rapidly gaining acceptance as a potential therapy for intermediate and advanced stage primary hepatocellular carcinoma and liver metastases. The technique involves delivery of Y90 infused glass microspheres via the hepatic arterial blood flow to the appropriate tumor. The liver tumor receives a highly concentrated radiation dose while sparing the healthy liver parenchyma due to its preferential blood supply from portal venous blood. There are two commercially available devices: TheraSphere® and SIR-Spheres®. Although, Y90-SIRT with glass microspheres improves median survival in patients with intermediate and advanced hepatocellular carcinoma and has the potential to downstage hepatocellular carcinoma so that the selected candidates meet the transplantable criteria, it has not gained widespread acceptance due to the lack of large randomized controlled trials. Currently, there are various clinical trials investigating the use of Y90-SIRT with glass microspheres for treatment of hepatocellular carcinoma and the outcomes of these trials may result in the incorporation of Y90-SIRT with glass microspheres into the treatment guidelines as a standard therapy option for patients with intermediate and advanced stage hepatocellular carcinoma

  3. Yttrium-90 selective internal radiation therapy with glass microspheres for hepatocellular carcinoma: Current and updated literature review

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Edward Wolfgang; Alanic, Lourdes [Div. of Interventional Radiology, Dept. of Radiology, UCLA Medical Center, David Geffen School of Medicine at UCLA, Los Angeles (United States); Cho, Sung Ki [Div. of Interventional Radiology, Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Saab, Sammy [Div. of Hepatology, Dept. of Medicine, Pfleger Liver Institute, University of California at Los Angeles, Los Angeles (United States)

    2016-07-15

    Hepatocellular carcinoma is the most common primary liver cancer and it represents the majority of cancer-related deaths in the world. More than 70% of patients present at an advanced stage, beyond potentially curative options. Ytrrium-90 selective internal radiation therapy (Y90-SIRT) with glass microspheres is rapidly gaining acceptance as a potential therapy for intermediate and advanced stage primary hepatocellular carcinoma and liver metastases. The technique involves delivery of Y90 infused glass microspheres via the hepatic arterial blood flow to the appropriate tumor. The liver tumor receives a highly concentrated radiation dose while sparing the healthy liver parenchyma due to its preferential blood supply from portal venous blood. There are two commercially available devices: TheraSphere® and SIR-Spheres®. Although, Y90-SIRT with glass microspheres improves median survival in patients with intermediate and advanced hepatocellular carcinoma and has the potential to downstage hepatocellular carcinoma so that the selected candidates meet the transplantable criteria, it has not gained widespread acceptance due to the lack of large randomized controlled trials. Currently, there are various clinical trials investigating the use of Y90-SIRT with glass microspheres for treatment of hepatocellular carcinoma and the outcomes of these trials may result in the incorporation of Y90-SIRT with glass microspheres into the treatment guidelines as a standard therapy option for patients with intermediate and advanced stage hepatocellular carcinoma.

  4. Yttrium-90 Selective Internal Radiation Therapy with Glass Microspheres for Hepatocellular Carcinoma: Current and Updated Literature Review

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Edward Wolfgang; Alanis, Lourdes [Division of Interventional Radiology, Department of Radiology, UCLA Medical Center, David Geffen School of Medicine at UCLA, Los Angeles, CA 90095 (United States); Cho, Sung-Ki [Division of Interventional Radiology, Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351 (Korea, Republic of); Saab, Sammy [Division of Hepatology, Department of Medicine, Pfleger Liver Institute, University of California at Los Angeles, Los Angeles, CA 90024 (United States)

    2016-11-01

    Hepatocellular carcinoma is the most common primary liver cancer and it represents the majority of cancer-related deaths in the world. More than 70% of patients present at an advanced stage, beyond potentially curative options. Ytrrium-90 selective internal radiation therapy (Y90-SIRT) with glass microspheres is rapidly gaining acceptance as a potential therapy for intermediate and advanced stage primary hepatocellular carcinoma and liver metastases. The technique involves delivery of Y90 infused glass microspheres via the hepatic arterial blood flow to the appropriate tumor. The liver tumor receives a highly concentrated radiation dose while sparing the healthy liver parenchyma due to its preferential blood supply from portal venous blood. There are two commercially available devices: TheraSphere® and SIR-Spheres®. Although, Y90-SIRT with glass microspheres improves median survival in patients with intermediate and advanced hepatocellular carcinoma and has the potential to downstage hepatocellular carcinoma so that the selected candidates meet the transplantable criteria, it has not gained widespread acceptance due to the lack of large randomized controlled trials. Currently, there are various clinical trials investigating the use of Y90-SIRT with glass microspheres for treatment of hepatocellular carcinoma and the outcomes of these trials may result in the incorporation of Y90-SIRT with glass microspheres into the treatment guidelines as a standard therapy option for patients with intermediate and advanced stage hepatocellular carcinoma.

  5. Yttrium-90 selective internal radiation therapy with glass microspheres for hepatocellular carcinoma: Current and updated literature review

    International Nuclear Information System (INIS)

    Lee, Edward Wolfgang; Alanic, Lourdes; Cho, Sung Ki; Saab, Sammy

    2016-01-01

    Hepatocellular carcinoma is the most common primary liver cancer and it represents the majority of cancer-related deaths in the world. More than 70% of patients present at an advanced stage, beyond potentially curative options. Ytrrium-90 selective internal radiation therapy (Y90-SIRT) with glass microspheres is rapidly gaining acceptance as a potential therapy for intermediate and advanced stage primary hepatocellular carcinoma and liver metastases. The technique involves delivery of Y90 infused glass microspheres via the hepatic arterial blood flow to the appropriate tumor. The liver tumor receives a highly concentrated radiation dose while sparing the healthy liver parenchyma due to its preferential blood supply from portal venous blood. There are two commercially available devices: TheraSphere® and SIR-Spheres®. Although, Y90-SIRT with glass microspheres improves median survival in patients with intermediate and advanced hepatocellular carcinoma and has the potential to downstage hepatocellular carcinoma so that the selected candidates meet the transplantable criteria, it has not gained widespread acceptance due to the lack of large randomized controlled trials. Currently, there are various clinical trials investigating the use of Y90-SIRT with glass microspheres for treatment of hepatocellular carcinoma and the outcomes of these trials may result in the incorporation of Y90-SIRT with glass microspheres into the treatment guidelines as a standard therapy option for patients with intermediate and advanced stage hepatocellular carcinoma

  6. Yttrium-90 Selective Internal Radiation Therapy with Glass Microspheres for Hepatocellular Carcinoma: Current and Updated Literature Review.

    Science.gov (United States)

    Lee, Edward Wolfgang; Alanis, Lourdes; Cho, Sung-Ki; Saab, Sammy

    2016-01-01

    Hepatocellular carcinoma is the most common primary liver cancer and it represents the majority of cancer-related deaths in the world. More than 70% of patients present at an advanced stage, beyond potentially curative options. Ytrrium-90 selective internal radiation therapy (Y90-SIRT) with glass microspheres is rapidly gaining acceptance as a potential therapy for intermediate and advanced stage primary hepatocellular carcinoma and liver metastases. The technique involves delivery of Y90 infused glass microspheres via the hepatic arterial blood flow to the appropriate tumor. The liver tumor receives a highly concentrated radiation dose while sparing the healthy liver parenchyma due to its preferential blood supply from portal venous blood. There are two commercially available devices: TheraSphere® and SIR-Spheres®. Although, Y90-SIRT with glass microspheres improves median survival in patients with intermediate and advanced hepatocellular carcinoma and has the potential to downstage hepatocellular carcinoma so that the selected candidates meet the transplantable criteria, it has not gained widespread acceptance due to the lack of large randomized controlled trials. Currently, there are various clinical trials investigating the use of Y90-SIRT with glass microspheres for treatment of hepatocellular carcinoma and the outcomes of these trials may result in the incorporation of Y90-SIRT with glass microspheres into the treatment guidelines as a standard therapy option for patients with intermediate and advanced stage hepatocellular carcinoma.

  7. Clinical outcomes of Y90 radioembolization for recurrent hepatocellular carcinoma following curative resection

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Rehan; Riaz, Ahsun; Gabr, Ahmed; Abouchaleh, Nadine; Mora, Ronald; Al Asadi, Ali [Northwestern University, Department of Radiology, Section of Interventional Radiology, Chicago, IL (United States); Caicedo, Juan Carlos; Abecassis, Michael; Katariya, Nitin [Northwestern University, Department of Surgery, Division of Transplant Surgery, Chicago, IL (United States); Maddur, Haripriya; Kulik, Laura [Northwestern University, Department of Medicine, Division of Hepatology, Chicago, IL (United States); Lewandowski, Robert J. [Northwestern University, Department of Radiology, Section of Interventional Radiology, Chicago, IL (United States); Northwestern University, Department of Medicine, Division of Hematology and Oncology, Chicago, IL (United States); Salem, Riad [Northwestern University, Department of Radiology, Section of Interventional Radiology, Chicago, IL (United States); Northwestern University, Department of Surgery, Division of Transplant Surgery, Chicago, IL (United States); Northwestern University, Department of Medicine, Division of Hematology and Oncology, Chicago, IL (United States)

    2017-12-15

    To assess safety/efficacy of yttrium-90 radioembolization (Y90) in patients with recurrent hepatocellular carcinoma (HCC) following curative surgical resection. With IRB approval, we searched our prospectively acquired database for patients that were treated with Y90 for recurrent disease following resection. Baseline characteristics and bilirubin toxicities following Y90 were evaluated. Intention-to-treat overall survival (OS) and time-to-progression (TTP) from Y90 were assessed. Forty-one patients met study inclusion criteria. Twenty-six (63%) patients had undergone minor (≤3 hepatic segments) resection while 15 (37%) patients underwent major (>3 hepatic segments) resections. Two patients (5%) had biliary-enteric anastomoses created during surgical resection. The median time from HCC resection to the first radioembolization was 17 months (95% CI: 13-37). The median number of Y90 treatment sessions was 1 (range: 1-5). Ten patients received (entire remnant) lobar Y90 treatment while 31 patients received selective (≤2 hepatic segments) treatment. Grades 1/2/3/4 bilirubin toxicity were seen in nine (22%), four (10%), four (10%), and zero (0%) patients following Y90. No differences in bilirubin toxicities were identified when comparing lobar with selective approaches (P = 0.20). No post-Y90 infectious complications were identified. Median TTP and OS were 11.3 (CI: 6.5-15.5) and 22.1 months (CI: 10.3-31.3), respectively. Radioembolization is a safe and effective method for treating recurrent HCC following surgical resection, with prolonged TTP and promising survival outcomes. (orig.)

  8. Comparison of positron emission tomography/CT and bremsstrahlung imaging following Y-90 radiation synovectomy

    International Nuclear Information System (INIS)

    Barber, Thomas W.; Yap, Kenneth S.K.; Cherk, Martin H.; Kalff, Victor; Powell, Anne

    2013-01-01

    The aim of this study is to compare the results of positron emission tomography (PET)/CT with bremsstrahlung imaging following Y-90 radiation synovectomy. All patients referred to our institution for Y-90 radiation synovectomy between July 2011 and February 2012 underwent both PET/CT and bremsstrahlung planar (±single photon emission computed tomography (SPECT) or SPECT/CT) imaging at 4 or 24 h following administration of Y-90 silicate colloid. PET image acquisition was performed for between 15 and 20min. In patients who underwent SPECT, side-by-side comparison with PET was performed and image quality/resolution scored using a five-point scale. The distribution pattern of Y-90 on PET and bremsstrahlung imaging was compared with the intra- or extra-articular location of Y-90 activity on fused PET/CT. Thirteen joints (11 knees and two ankles) were imaged with both PET/CT and planar bremsstrahlung imaging with 12 joints also imaged with bremsstrahlung SPECT. Of the 12 joints imaged with SPECT, PET image quality/resolution was superior in 11 and inferior in one. PET demonstrated a concordant distribution pattern compared with bremsstrahlung imaging in all scans, with the pattern classified as diffuse in 12 and predominantly focal in one. In all 12 diffuse scans, PET/CT confirmed the Y-90 activity to be located intra-articularly. In the one predominantly focal scan, the fused PET/CT images localised the Y-90 activity to mostly lie in the extra-articular space of the knee. PET/CT can provide superior image quality compared with bremsstrahlung imaging and may enable reliable detection of extra-articular Y-90 activity when there are focal patterns on planar bremsstrahlung imaging.

  9. Radiation Safety in Production of Y-90 from an electrochemical generator. CENTIS experience

    International Nuclear Information System (INIS)

    Ayra Pardo, Fernando Enrique

    2016-01-01

    From a project with the International Atomic Energy Agency, Isotope Center installation and commissioning began operating an electrochemical generator of Sr-90 / Y-90 inside a glove box shielded. The aim was to ensure the production of Y-90 needed in the research carried out in Cuba with this radionuclide for the medical industry. Associate at the beginning of this practice, compliance with all regulatory requirements approved in the country from the radiological point of view that demonstrated the safety of this for both operators and the general public became necessary. Using the MCNPX code generator installation was simulated and the equivalent dose Hp (10) were obtained for the operator: 6.27 mSv / y Hp (0.07): 17 mSv / a for a source of 10 Ci of 90 Sr- 90 Y . Also the use of TLD dosimeters similar to those used for gamma emitting radionuclides for controlling beta exposures was evaluated. high sensitivity lithium fluoride tablets couple energy beta particles of Y-90 which ensures its use for measuring the magnitude Hp (007) was demonstrated. two possible solutions for the recovery of liquid waste 90 Sr one another by distillation and ion exchange are evaluated. To transport the Y-90 may be used the package currently used in marketing the rest of the CENTIS radiopharmaceuticals. As a final result, the practice was approved and included in the Operating License Center Isotopes. (author)

  10. Y-90 PET imaging for radiation theragnosis using bootstrap event re sampling

    International Nuclear Information System (INIS)

    Nam, Taewon; Woo, Sangkeun; Min, Gyungju; Kim, Jimin; Kang, Joohyun; Lim, Sangmoo; Kim, Kyeongmin

    2013-01-01

    Surgical resection is the most effective method to recover the liver function. However, Yttrium-90 (Y-90) has been used as a new treatment due to the fact that it can be delivered to the tumors and results in greater radiation exposure to the tumors than using external radiation nowadays since most treatment is palliative in case of unresectable stage of hepatocellular carcinoma (HCC). Recently, Y-90 has been received much interest and studied by many researchers. Imaging of Y-90 has been conducted using most commonly gamma camera but PET imaging is required due to low sensitivity and resolution. The purpose of this study was to assess statistical characteristics and to improve count rate of image for enhancing image quality by using nonparametric bootstrap method. PET data was able to be improved using non-parametric bootstrap method and it was verified with showing improved uniformity and SNR. Uniformity showed more improvement under the condition of low count rate, i.e. Y-90, in case of phantom and also uniformity and SNR showed improvement of 15.6% and 33.8% in case of mouse, respectively. Bootstrap method performed in this study for PET data increased count rate of PET image and consequentially time for acquisition time can be reduced. It will be expected to improve performance for diagnosis

  11. Preparation of (YCl3)-Y-90 radiopharmaceutical precursor for nuclear medicine using technology of centrifugal extractors

    Czech Academy of Sciences Publication Activity Database

    Šrank, Jiří; Melichar, František; Filyanin, A.T.; Tomeš, Marek; Beran, Miloš

    2010-01-01

    Roč. 68, č. 12 (2010), s. 2163-2168 ISSN 0969-8043 R&D Projects: GA MŠk OE08018 Institutional research plan: CEZ:AV0Z10480505 Keywords : Y-90 radionuclide precursor * Extraction separation * Centrifugal extractors Subject RIV: FR - Pharmacology ; Medidal Chemistry Impact factor: 0.999, year: 2010

  12. Microradiographic microsphere manipulator

    International Nuclear Information System (INIS)

    Singleton, R.M.

    1980-01-01

    A method and apparatus are provided for radiographic characterization of small hollow spherical members (microspheres), constructed of either optically transparent or opaque materials. The apparatus involves a microsphere manipulator which holds a batch of microspheres between two parallel thin plastic films for contact microradiographic characterization or projection microradiography thereof. One plastic film is translated to relative to and parallel to the other to roll the microspheres through any desired angle to allow different views of the microspheres

  13. Accumulation of Sr90-Y90 by the developing spawn and larvae of Coregonus lavaretus L

    International Nuclear Information System (INIS)

    Kulikov, N.V.; Ozhegov, L.N.

    1976-01-01

    The results are given of laboratory experiments aimed at studying accumulation of Sr-90 and its daughter product Y-90 in the spawn and larvae of whitefish, a representative of autumn spawning fish species. The results are of interest for predicting possible consequences of radioactive contamination of water bodies and introduction of limits for permissible concentration of radioactive substances in aqueous medium. The accumulation coefficient of Sr-90 in the spawn reaches its maximum after the first twenty four hours of the experiment. Subsequently throughout the incubation period the accumulation coefficient (AC) of radionuclide does not undergo any changes being about 3. Besides it has been established that the equilibrium distribution of Sr-90 in whitefish spawn and the surrounding solution occurs during the first two hours. Unlike Sr-90 the accumulation of Y-90 occurs during the whole incubation period and results in the AC value of 80 by the end of the spawn incubation. The experiments aimed at determining the strength of radionuclide fixation by whitefish spawn and larvae revealed that both radionuclides in the spawn are rather mobile. Strontium separates fully from it during the first twenty four hours and yttrium marked by higher fixation strength transfers completely from the spawn into surrounding aqueous medium by the end of the experiment. In larvae the radionuclides are fixed stroger than in the spawn. The approximate radiation doses of embryos by the time of their hatching have been estimated. The estimates indicate that the total radiation dose of the spawn developing in aqueous solution of Sr-90 - Y-90 with 1.1 curie/0 -5 concentration is about 500 radl

  14. Long term follow-up after synovectomy with Y-90 in patients with arthritis

    International Nuclear Information System (INIS)

    Budihna, N.V.; Golja-Kos, M.; Batagelj, I.

    1994-01-01

    The purpose of the study was to evaluate the success rate of synoviorthesis in 273 patients with painful and swollen large joints (jts), up to nine years after the intraarticular application of Y-90. 402 knees, and 64 shoulders or ankles were treated. Rheumatoid arthritis was present in 449 jts, 64 jts were afflicted by osteoarthritis or other rheumatic diseases. 185 MBq were applied in knees and shoulders and 111 MBq of Y-90 in ankles. The effect of therapy was evaluated considering the degree of morning stiffness, pain and swelling. The effect of therapy was moderate in 42.5%%, good in 30.6% and very good in 14.9%% of jts. There was no improvement noted in 11.8%% of jts. The duration of improvement was in average 2.8 years. In 11 %% of pts the improvement lasted 6-9 years after therapy. Transient side effects were noted in 5.6%% of pts, pain and swelling were most frequent. Malignant diseases developed during the follow-up period (less than 4 years) in three pts. We conclude that radioisotopic synoviorthesis mostly has a satisfactory effect with mean duration of 2.8 years. Serious side effects were rare. (author)

  15. Efficacy of Radiation Synovectomy with Y-90 in chronic knee joint synovitis

    International Nuclear Information System (INIS)

    Roiz, C.; Raigoso, P.; Suarez, J.P.; Llana, B.; Zeidan, N.; Dominguez, M.L.; Bernardo, L.; Fernandez, J.A.; Nunez, R.

    2002-01-01

    Aim: To evaluate the efficiency of Radiation Synovectomy (RSO) with Y-90 in knee joints of patients with chronic synovitis (CS) resistant to classical conventional therapy, and assess its long-term prognosis. Material and Methods: 22 patients (7 males,15 females, mean age 50, range 12-81) with CS of the knees, of a duration ranging from 2 to 48 years, were included in the study. All patients had suffered from CS for more than 6 months, and were resistant to anti-inflammatory drugs, immunosuppressants and intraarticular (IA) steroid therapy. The cases included:10 patients with rheumatoid arthritis (RA), 5 psoriatic arthritis (PA), 3 pigmented villonodular synovitis, 2 seronegative oligo-polyarthritis and 2 chronic mono arthritis. We used an IA dose of 3 to 5 mCi (37-185 MBq)of Y-90. The effect of the therapy with Y-90 on 22 knees was evaluated from 3 to 12 months after the RSO. Patients' response was assess and classified according to the results of plain radiology and following conventional rheumatological criteria as: A) Excellent (E) with a visual improvement (VI) of 80-100mm, no pain in motion, little or no palpable swelling, no inflammation; B) Good (G) VI of 60-90mm, minimal pain in motion, little palpable swelling; C) Mild (M) VI of 20-59mm, moderate reduction of pain, obvious swelling; D) Bad (B) VI of only 0-19 mm, no changes or an increase of pain in the swollen joints. Results: The response observed was classified as: E in 5 patients (23%); G in 10 patients (45%); M in 3 patients (14%); and B in 4(18%). The 4 patients with a response B, had all of them joint erosion on plain radiology. Furthermore, one of the patients was a failure from prior surgical synovectomy (SS). The other 3 patients subsequently had SS. In contrast, all the responses E and G were obtained exclusively in patients with RA or PA. No short or long-term adverse side effects were noted. Conclusion: RSO is an effective treatment for patients with persistent CS, specially in RA and PA. The

  16. Metallic coating of microspheres

    International Nuclear Information System (INIS)

    Meyer, S.F.

    1980-01-01

    Extremely smooth, uniform metal coatings of micrometer thicknesses on microscopic glass spheres (microspheres) are often needed as targets for inertial confinement fusion (ICF) experiments. The first part of this paper reviews those methods used successfully to provide metal coated microspheres for ICF targets, including magnetron sputtering, electro- and electroless plating, and chemical vapor pyrolysis. The second part of this paper discusses some of the critical aspects of magnetron sputter coating of microspheres, including substrate requirements, the sticking of microspheres during coating (preventing a uniform coating), and the difficulties in growing the desired dense, smooth, uniform microstructure on continuously moving spherical substrates

  17. Effects of hepatic arterial yttrium 90 glass microspheres in dogs.

    Science.gov (United States)

    Wollner, I; Knutsen, C; Smith, P; Prieskorn, D; Chrisp, C; Andrews, J; Juni, J; Warber, S; Klevering, J; Crudup, J

    1988-04-01

    A 22-micron glass microsphere called TheraSphere (Theragenics Corp., Atlanta, GA) has been developed in which yttrium 89 oxide is incorporated into the glass matrix and is activated by neutron bombardment to form the beta-emitting isotope yttrium 90 (Y 90) before using the spheres as radiotherapeutic vehicles. The injection of up to 12 times (on a liver weight basis) the anticipated human dose of nonradioactive TheraSphere into the hepatic arteries of dogs was well tolerated and produced clinically silent alterations within centrolobular areas. The hepatic arterial (HA) injection of radioactive TheraSphere also produced portal changes similar to those observed in humans after external beam therapy. While the extent of damage increased with the delivered dose, radiation exposures in excess of 30,000 cGy did not cause total hepatic necrosis and were compatible with survival. No microspheres distributed to the bone marrow and absolutely no myelosuppression was encountered in any animal. Proposed hepatic exposures to humans of 5000 to 10,000 cGy by means of these microspheres, therefore, would appear to be feasible and tolerable. Radiotherapeutic microsphere administration preceded by regional infusion of a radiosensitizing agent and/or immediately following the redistribution of blood flow toward intrahepatic tumor by vasoactive agents can potentially yield a synergistic, highly selective attack on tumors confined to the liver.

  18. Validation of Extraction Paper Chromatography as a Quality Control Technique for Analysis of Sr-90 in Y-90 Product

    International Nuclear Information System (INIS)

    Nipavan, Poramatikul; Jatupol, Sangsuriyan; Wiranee, Sriweing

    2009-07-01

    Full text: Yttrium-90 (Y-90) is a daughter product of strontium-90 (Sr-90). It is specified that there should be less than 2 micro-curie of Sr-90 in Y-90 radiopharmaceuticals. Since both nuclides are beta emitting and there is always a contamination of Y-90 in Sr-90 sample, validation of the analytical method is necessary. In this study, commercial Y-90 and Sr-85 (a gamma emitting isotope of strontium) were used as daughter and mother nuclides, respectively. Extraction paper chromatography technique and its efficient validation method were investigated. Bis-(2-ethylhexyl) diphosphonate was dropped at the origin of chromatography paper and air dried prior to sample drops. Validation of the separation was done by radio-chromatography scanning of the chromatography paper. Their energy spectra were identified in the spectra mode of Packard Cobra II automatic gamma counter, which can differentiate a pure gamma, a pure beta and a mixture of beta and gamma nuclides. Results showed that yttrium acetate remained fixed at the origin of the chromatography paper while strontium acetate moved to the solvent front when developed in saline. In conclusion, the extraction paper chromatography technique can effectively separate Sr-90 from Y-90

  19. Assessing Intra-arterial Complications of Planning and Treatment Angiograms for Y-90 Radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Osman, E-mail: osman1423@gmail.com [Rush University Medical Center, Section of Interventional Radiology, Department of Radiology (United States); Patel, Mikin V. [University of Chicago, Department of Radiology (United States); Masrani, Abdulrahman; Chong, Bradford; Osman, Mohammed; Tasse, Jordan; Soni, Jayesh; Turba, Ulku Cenk; Arslan, Bulent [Rush University Medical Center, Section of Interventional Radiology, Department of Radiology (United States)

    2017-05-15

    PurposeTo report hepatic arterial-related complications encountered during planning and treatment angiograms for radioembolization and understand any potential-associated risk factors.Materials and Methods518 mapping or treatment angiograms for 180 patients with primary or metastatic disease to the liver treated by Yttrium-90 radioembolization between 2/2010 and 12/2015 were retrospectively reviewed. Intra-procedural complications were recorded per SIR guidelines. Patient demographics, indication for treatment, prior exposure to chemotherapeutic agents, operator experience, and disease burden were reviewed. Technical variables including type of radioembolic (glass vs. resin microspheres), indication for angiography (mapping vs. treatment), variant anatomy, and attempts at coil embolization were also assessed.ResultsThirteen (13/518, 2.5%) arterial-related complications occurred in 13 patients. All but two complications resulted during transcatheter coil embolization to prevent non-target embolization. Complications included coil migration (n = 6), arterial dissection (n = 2), focal vessel perforation (n = 2), arterial thrombus (n = 2), and vasospasm prohibiting further arterial sub-selection (n = 1). Transarterial coiling was identified as a significant risk factor of complications on both univariate and multivariate regression analysis (odds ratio 7.8, P = 0.004). Usage of resin microspheres was also a significant risk factor (odds ratio 9.5, P = 0.042). No other technical parameters or pre-procedural variables were significant after adjusting for confounding on multivariate analysis (P > 0.05).ConclusionIntra-procedural hepatic arterial complications encountered during radioembolization were infrequent but occurred mainly during coil embolization to prevent non-target delivery to extra-hepatic arteries.

  20. Country report: Germany. Preclinical evaluation of Y-90 labelled Rituximab and ERIC-1, two antibodies for tumor therapy

    Energy Technology Data Exchange (ETDEWEB)

    Schomäcker, Klaus; Fischer, Thomas [Department of Nuclear Medicine, University of Cologne, Cologne (Germany)

    2010-07-01

    This project focuses on harnessing the great potential of radionuclide therapy, using various different vehicles to transport radionuclides into tumor tissues. A central aim of the project will be to manufacture specific vehicle molecules whose tumor affinity and suitability for radioactive coupling have already been proven through laboratory trials on animals and cell cultures at the Department of Nuclear Medicine, University of Cologne and to label it with Y- 90. The vectors to be used to transport radionuclides into tumor tissue for treatment are antibodies against lymphomas and neuroblastomas. The technology applied for coupling Y-90 to various antibodies has been developed to a high level in Cologne and is now ready to be transferred and adapted to GMP (Good Manufacturing Practice) conditions. The antibody against NHL can be acquired commercially and must then be modified for binding to the therapeutically active nuclide Y-90. Similarly, the antibody against neuroblastoma must also be modified to bind to Y-90 but is produced in Cologne. To improve the therapeutic value of antibodies we tried to introduce the pretargeting method.

  1. Country report: Germany. Preclinical evaluation of Y-90 labelled Rituximab and ERIC-1, two antibodies for tumor therapy

    International Nuclear Information System (INIS)

    Schomäcker, Klaus; Fischer, Thomas

    2010-01-01

    This project focuses on harnessing the great potential of radionuclide therapy, using various different vehicles to transport radionuclides into tumor tissues. A central aim of the project will be to manufacture specific vehicle molecules whose tumor affinity and suitability for radioactive coupling have already been proven through laboratory trials on animals and cell cultures at the Department of Nuclear Medicine, University of Cologne and to label it with Y- 90. The vectors to be used to transport radionuclides into tumor tissue for treatment are antibodies against lymphomas and neuroblastomas. The technology applied for coupling Y-90 to various antibodies has been developed to a high level in Cologne and is now ready to be transferred and adapted to GMP (Good Manufacturing Practice) conditions. The antibody against NHL can be acquired commercially and must then be modified for binding to the therapeutically active nuclide Y-90. Similarly, the antibody against neuroblastoma must also be modified to bind to Y-90 but is produced in Cologne. To improve the therapeutic value of antibodies we tried to introduce the pretargeting method

  2. Patent hepatic falciform artery detected after Tc-99m-macroaggregated albumin injection on SPECT/CT prior to Yttrium-90 microsphere radioembolization: a case report

    International Nuclear Information System (INIS)

    Karaman, B.; Aslan, A.; Hamcan, S.; Ugurel, M.

    2012-01-01

    Full text: Introduction: Yttrium-90 (Y-90) microsphere radioembolization is increasingly used for the treatment of unresectable hepatocellular carcinoma and liver metastasis. Objectives and tasks: We aim to present the upper abdominal wall skin involvement detected during routine pre-therapy Technetium-99m-macroaggregated albumin (Tc-99m-MAA) on SPECT/CT due to patent hepatic falciform artery and the precautions to avoid this potential complication. Material and methods: 38-year-old male with colon cancer and multiple liver metastasis was evaluated prior to radioembolization and Tc-99 MAA was slowly hand injected at the bifurcation of the proper hepatic artery. Then, the SPECT/CT scan was performed in order to investigate the systemic shunt or gastric involvement. Results: On SPECT/CT scan, involvement of the upper abdominal wall through falciform ligament was seen. Re-evaluation of the hepatic angiogram identified a patent hepatic falciform artery arising from the left hepatic artery. Y-90 microspheres were slowly hand injected to the left hepatic artery superselectively and no extra-hepatic activity was seen on SPECT/CT scan. Conclusion: Upper abdominal pain and dermatitis are uncommon findings after radioembolization and may occur due to inadvertent delivery of Y-90 microspheres into patent hepatic falciform artery. To prevent these complications, either patent hepatic falciform artery must be embolized by coil or Y-90 injection must be performed superselectively

  3. Preoperative evaluation

    International Nuclear Information System (INIS)

    Murphy, C.H.; Murphy, M.R.

    1987-01-01

    The value of a preoperative chest radiograph is twofold. The examination may reveal unsuspected pathology that would alter the approach to surgery of anesthesia. Secondly, it provides a baseline or reference from which to evaluate subsequent post-operative films. The percentage of detection of unsuspected pathology on preoperative chest radiographs has been shown to be exceedingly small in certain patient populations. The authors do not recommend routine use of preoperative chest radiographs in children or in adults under the age of 40 who do not smoke, unless (1) the surgical disease has chest manifestations; (2) there is historic or clinical evidence of a coexisting disease with chest involvement; or (3) there is a likelihood that post-operative management will require follow-up films

  4. Country report: Syria. Development of 90Y/90Sr Generator and 90Y Radiopharmaceuticals

    International Nuclear Information System (INIS)

    Yassine, Taufik; Mukhallalati, Ch. Heyam

    2010-01-01

    The aim of this project is to develop a technique for preparation of 90 Sr- 90 Y generator, we have developed a separation technique for isolation of 90 Y from 90 Sr based on using Sr – Spec resin packed in three columns for separation and purification of 90 Sr- 90 Y .The resulting Y90 is used for therapeutic applications. The first part of this project describe a prototype design for the 90 Sr- 90 Y generator in order to get a very accurate method to obtain the minimum possible 90 Sr Breakthrough. 25 mci of 90 Sr was used in the generator 90 Sr- 90 Y and we obtained the elution yield of 90 Y higher than 88%, Also the eluate was used for preparation of several 90 Y radiopharmaceuticals such as 90 YEDTMP and 90 Y-DOTA-HR 3 . And the work is continues to investigate more radiopharmaceuticals applications in the second part of this project such as 90 Y– FHMA. In this part of the co-coordination research programmer, A protocol based on results of this studies was developed to prepare and operate a higher activity generator (50-100mci), the resulting elution yield was approximately 94% of 90 Y . The elute was used in preparation of new 90 Y radiopharmaceuticals. The monoclonal antibodies is still evolving by conjugate Rituximab to The macrocyclic bifunctional chelating agent,(p-SCN-Bn-DOTA)S-2-(4-Isothiocyanatobenzyle)-1,4,7,10- tetraazacyclododecane-tetraaceticacid to obtain the inmunoconjugate DOTA-Rituximub in simple way and then investigating the radio labeling conditions with 90 Y. (author)

  5. A collimator optimization method for quantitative imaging: application to Y-90 bremsstrahlung SPECT.

    Science.gov (United States)

    Rong, Xing; Frey, Eric C

    2013-08-01

    Post-therapy quantitative 90Y bremsstrahlung single photon emission computed tomography (SPECT) has shown great potential to provide reliable activity estimates, which are essential for dose verification. Typically 90Y imaging is performed with high- or medium-energy collimators. However, the energy spectrum of 90Y bremsstrahlung photons is substantially different than typical for these collimators. In addition, dosimetry requires quantitative images, and collimators are not typically optimized for such tasks. Optimizing a collimator for 90Y imaging is both novel and potentially important. Conventional optimization methods are not appropriate for 90Y bremsstrahlung photons, which have a continuous and broad energy distribution. In this work, the authors developed a parallel-hole collimator optimization method for quantitative tasks that is particularly applicable to radionuclides with complex emission energy spectra. The authors applied the proposed method to develop an optimal collimator for quantitative 90Y bremsstrahlung SPECT in the context of microsphere radioembolization. To account for the effects of the collimator on both the bias and the variance of the activity estimates, the authors used the root mean squared error (RMSE) of the volume of interest activity estimates as the figure of merit (FOM). In the FOM, the bias due to the null space of the image formation process was taken in account. The RMSE was weighted by the inverse mass to reflect the application to dosimetry; for a different application, more relevant weighting could easily be adopted. The authors proposed a parameterization for the collimator that facilitates the incorporation of the important factors (geometric sensitivity, geometric resolution, and septal penetration fraction) determining collimator performance, while keeping the number of free parameters describing the collimator small (i.e., two parameters). To make the optimization results for quantitative 90Y bremsstrahlung SPECT more

  6. Glass microspheres for brachytherapy

    International Nuclear Information System (INIS)

    Prado, Miguel O.; Prastalo, Simon; Blaumann, Herman; Longhino, Juan M.; Repetto Llamazares, A.H.V.

    2007-01-01

    We developed the capacity to produce glass microspheres containing in their structure one or more radioactive isotopes useful for brachytherapy. We studied the various facts related with their production: (Rare earth) alumino silicate glass making, glass characterization, microspheres production, nuclear activation through (n,γ) nuclear reactions, mechanical characterization before and after irradiation. Corrosion tests in simulated human plasma and mechanical properties characterization were done before and after irradiation. (author) [es

  7. Method for sizing hollow microspheres

    Science.gov (United States)

    Farnum, E.H.; Fries, R.J.

    1975-10-29

    Hollow Microspheres may be effectively sized by placing them beneath a screen stack completely immersed in an ultrasonic bath containing a liquid having a density at which the microspheres float and ultrasonically agitating the bath.

  8. Ceramic microspheres for cementing applications

    NARCIS (Netherlands)

    2011-01-01

    A method and apparatus for manufacturing ceramic microspheres from industrial slag. The microspheres have a particle size of about 38 microns to about 150 microns. The microspheres are used to create a cement slurry having a density of at least about 11 lbs/g. The resultant cement slurry may then be

  9. Ceramic microspheres for cementing applications

    NARCIS (Netherlands)

    2010-01-01

    A method and apparatus for manufacturing ceramic microspheres from industrial slag. The microspheres have a particle size of about 38 microns to about 150 microns. The microspheres are used to create a cement slurry having a density of at least about 11 lbs/g. The resultant cement slurry may then be

  10. Ceramic microspheres for cementing applications

    NARCIS (Netherlands)

    2012-01-01

    A method and apparatus for manufacturing ceramic microspheres from industrial slag. The microspheres have a particle size of about 38 microns to about 150 microns. The microspheres are used to create a cement slurry having a density of at least about 11 lbs/g. The resultant cement slurry may then be

  11. Preparation of alumina microspheres

    International Nuclear Information System (INIS)

    Santos, W.R. dos; Abrao, A.

    1980-01-01

    Inorganic exchangers are widely used for adsorption and column partition chromatography. The main difficulty of using commercial alumina (in powder) for column chromatography is related to its packing, and the operations through the column become diffcult and time-consuming; also it turns to be virtually impossible to use large dimension columns. In order to eliminate these problems, a process for the preparation of alumina micro-spheres was developed as an adaptation of a similar process used to prepare nuclear fuel microspheres (UO 2 , ThO 2 ). The flowsheet of this process is presented together with the analytical results of sphericity after calcination, granulometry, density and characterization by X-ray diffractometry. Solubility tests showed that the so-prepared microspheres are well resistant to strong acids and bases; retention tests showed their efficiency, mainly to copper. (C.L.B.) [pt

  12. Carefully calibrated microsphere embolization of tumors and AVMs

    International Nuclear Information System (INIS)

    Laurent, A.; Wassef, M.; Beaujeux, R.; Hodes, J.E.; Gobin, P.Y.; Schenker, C.; Bouchez, B.; Brette, M.D.; Aymard, A.; Cophignon, J.; Merland, J.J.

    1990-01-01

    This paper evaluates the efficacy of a new type of uniformly calibrated microsphere for embolization of various pathologies. Fourteen tumors (five intracranial, eight extracranial, one spine), and seven facial arteriovenous malformations (AVMs) (nose, lip, and scalp) were embolized preoperatively. Angiographic, surgical devascularization, and histologic findings were correlated with the spheres' size. In the second part of the study, spinal cord (n = 22) and intracerbral (n = 14) AVM, Weber-Osler-Rendu disease (n = 2), and epistaxis (n = 1) embolization was angiographically evaluated

  13. Silicon Microspheres Photonics

    International Nuclear Information System (INIS)

    Serpenguzel, A.

    2008-01-01

    Electrophotonic integrated circuits (EPICs), or alternatively, optoelectronic integrated circuit (OEICs) are the natural evolution of the microelectronic integrated circuit (IC) with the addition of photonic capabilities. Traditionally, the IC industry has been based on group IV silicon, whereas the photonics industry on group III-V semiconductors. However, silicon based photonic microdevices have been making strands in siliconizing photonics. Silicon microspheres with their high quality factor whispering gallery modes (WGMs), are ideal candidates for wavelength division multiplexing (WDM) applications in the standard near-infrared communication bands. In this work, we will discuss the possibility of using silicon microspheres for photonics applications in the near-infrared

  14. 90Y/90 Sr electron induced damages in an essential eucalyptus oil related to the absorbed dose

    International Nuclear Information System (INIS)

    Heredia Cardona, J.A.; Diaz Rizo, O.; Martinez Luzardo, F.; Quert, R.

    2007-01-01

    A good irradiation geometry was achieved in order to carry out the irradiation of an essential eucalyptus oil with a 90 Y/ 90 Sr electron source. The Monte Carlo simulation code MCNP-4C was employed to determine the absorbed doses in this particular experimental configuration. It also helped us to understand which electrons (from an energetic point of view) were responsible for the damages. In order to identify the induced damages, the irradiated samples were studied by mass spectrometry. The obtained results were related to the absorbed doses determined by the computational simulation

  15. Synthesis of magnetic polymeric microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Gervald, A Yu; Gritskova, Inessa A; Prokopov, Nikolai I [M.V. Lomonosov Moscow State Academy of Fine Chemical Technology, Moscow (Russian Federation)

    2010-05-13

    The key types of magnetic polymeric microspheres are considered. Methods of synthesis of different types of magnetic nanoparticles and of preparation of stable magnetic fluids on their basis are outlined. The overview of the methods for the manufacture of magnetic polymeric microspheres is presented. The effect of the synthesis conditions on the characteristics of magnetic polymeric microspheres such as the diameter and the particle size distribution and the content of magnetic material is discussed by particular examples. The application fields of magnetic polymeric microspheres are briefly surveyed.

  16. Synthesis of magnetic polymeric microspheres

    International Nuclear Information System (INIS)

    Gervald, A Yu; Gritskova, Inessa A; Prokopov, Nikolai I

    2010-01-01

    The key types of magnetic polymeric microspheres are considered. Methods of synthesis of different types of magnetic nanoparticles and of preparation of stable magnetic fluids on their basis are outlined. The overview of the methods for the manufacture of magnetic polymeric microspheres is presented. The effect of the synthesis conditions on the characteristics of magnetic polymeric microspheres such as the diameter and the particle size distribution and the content of magnetic material is discussed by particular examples. The application fields of magnetic polymeric microspheres are briefly surveyed.

  17. Clinical results of intravenous and intra-arterial peptide receptor radionuclide therapy (PRRT) using Y-90 and Lu-177 DOTA-TYR3-OCTREOTATE (Y-90 DOTA-TATE) in 151 patents with metastatic progressive neuroendocrine tumors (NET)

    International Nuclear Information System (INIS)

    Baum, R.P.; Soeldner, J.; Strauss, H.-J.

    2005-01-01

    We investigated the anti-tumor efficacy and adverse effects of the somatostatin analog octreotate labelled with Y-90 or Lu-177 in patients with progressive neuroendocrine tumors and severe tumour burden. 151 patients (69 f and 82 m, age range=19-81 yrs), 307 administrations, Mean activity per cycle 3.35 GBq (max. 7000 MBq) and time between cycles 3 to 6 months. 7 pts received intra-arterial injections (8 cycles). All patients were selected based on high SST-R expression as proven by immunohistochemistry and Ga-68 DOTA-NOC receptor PET/CT or somatostatin scintigraphy. Re-staging was done using Ga-68 DOTA-NOC PET/CT, MRI, FDG-PET/CT, SST-R scintigraphy, F-18-Fluoride-PET/CT, renal scintigraphy (MAG 3), GFR measurements (DTPA) and monthly laboratory tests (haematology, liver enzymes, renal parameters, tumour markers). Results revealed 2 patients with complete remission (de novo therapy), Partial remission (PR) in 37 %, Stable disease (SD) in 52 % and disease progression (DP) in 11%. Objective tumour response (including improvement of symptoms) was seen in 85 % of the patients. A few adverse effects were also noted: Nausea and vomiting occurred in 35 % of female, and in 15 % of male patients. Anemia, leucocytopenia and thrombocytopenia (G2-3) observed in less than <15 %. None of the pts developed myelodysplastic syndrome. No hair loss was observed. We conclude that PRRT with Y-90/Lu-177 DOTA-TATE results in a high response rate with significant improvement of clinical symptoms; the treatment is tolerated with low toxicity and few adverse effects and shows promising results also in pts with progressive neuroendocrine tumours after biological treatment(interferon/sandostatin) or after chemotherapy. Renal toxicity can be reduced by prolonging the intervals between therapy cycles and reducing the maximum activity per cycle ('Bad Berka concept')

  18. Absorbed doses profiles vs Synovia tissue depth for the Y-90 and P-32 used in radiosynoviortesis treatment; Perfiles de dosis absorbida vs profundidad de tejido sinovial para el Y-90 y el P-32 empleados en tratamiento de radiosinoviortesis

    Energy Technology Data Exchange (ETDEWEB)

    Torres B, M.B.; Ayra P, F.E. [Centro de Isotopos (Cuba); Garcia R, E. [Hospital General Docente Enrique Cabrera (Cuba); Cornejo D, N. [CPHR, (Cuba); Yoriyaz, H. [IPEN, (Brazil)]. e-mail: nestor@cphr.edu.cu

    2006-07-01

    The radiosynoviortesis treatment has been used during more of 40 years as an alternative to the chemical and surgical synovectomy to alleviate the pain and to reduce the inflammation in suffered patients of rheumatic arthropathies, haemophilic arthropathies and other articulation disorders. It consists on the injection of radioactive isotopes inside a synovial cavity. For to evaluate the dosimetry of the radiosynoviortesis treatment is of great interest to know the absorbed dose in the volume of the target (synovia). The precise calculation of the absorbed dose in the inflamed synovia it is difficult, for numerous reasons, since the same one will depend on the thickness of the synovial membrane, the size of the articular space, the structure of the synovial membrane, the distribution in the articulation, the nature of the articular liquid, etc. Also the presence of the bone and the articular cartilage, components also of the articulation, it even complicated more the calculations. The method used to evaluate the dosimetry in radioactive synovectomy is known as the Monte Carlo method. The objective of our work consists on estimating with the Monte Carlo code MCNP4B the absorbed dose of the Y-90 and the P-32 in the depth of the synovial tissue. The results are presented as absorbed dose for injected millicurie (Gy/mCi) versus depth of synovial tissue. The simulation one carries out keeping in mind several synovia areas, of 50 cm{sup 2} to 250 cm{sup 2} keeping in mind three states of progression of the illness. Those obtained values of absorbed dose using the MCNP4B code will allow to introduce in our country an optimized method of dose prescription to the patient, to treat the rheumatic arthritis in medium and big articulations using the Y-90 and the P-32, eliminating the fixed doses and fixed radionuclides for each articulation like it happens in many clinics of Europe, as well as the empiric doses. (Author)

  19. Absorbed doses profiles vs Synovia tissue depth for the Y-90 and P-32 used in radiosynoviortesis treatment

    International Nuclear Information System (INIS)

    Torres B, M.B.; Ayra P, F.E.; Garcia R, E.; Cornejo D, N.; Yoriyaz, H.

    2006-01-01

    The radiosynoviortesis treatment has been used during more of 40 years as an alternative to the chemical and surgical synovectomy to alleviate the pain and to reduce the inflammation in suffered patients of rheumatic arthropathies, haemophilic arthropathies and other articulation disorders. It consists on the injection of radioactive isotopes inside a synovial cavity. For to evaluate the dosimetry of the radiosynoviortesis treatment is of great interest to know the absorbed dose in the volume of the target (synovia). The precise calculation of the absorbed dose in the inflamed synovia it is difficult, for numerous reasons, since the same one will depend on the thickness of the synovial membrane, the size of the articular space, the structure of the synovial membrane, the distribution in the articulation, the nature of the articular liquid, etc. Also the presence of the bone and the articular cartilage, components also of the articulation, it even complicated more the calculations. The method used to evaluate the dosimetry in radioactive synovectomy is known as the Monte Carlo method. The objective of our work consists on estimating with the Monte Carlo code MCNP4B the absorbed dose of the Y-90 and the P-32 in the depth of the synovial tissue. The results are presented as absorbed dose for injected millicurie (Gy/mCi) versus depth of synovial tissue. The simulation one carries out keeping in mind several synovia areas, of 50 cm 2 to 250 cm 2 keeping in mind three states of progression of the illness. Those obtained values of absorbed dose using the MCNP4B code will allow to introduce in our country an optimized method of dose prescription to the patient, to treat the rheumatic arthritis in medium and big articulations using the Y-90 and the P-32, eliminating the fixed doses and fixed radionuclides for each articulation like it happens in many clinics of Europe, as well as the empiric doses. (Author)

  20. Review: microspheres for radioembolization therapy

    International Nuclear Information System (INIS)

    Zhao Mingqiang; Xu Shuhe

    2007-12-01

    Radioembolization of liver cancer has been proven to be an effective therapy in nuclear medicine. The yttrium-90 glass microspheres has been used to treat both primary and metastatic liver tumors in clinic which shown encouraging results. The preparation, stability, degradation and application for medical purpose of radioactive microspheres are reviewed. At first, the theory of radioem- bolization treating cancer is discussed; and then three major radiolabled micro- sphere materials are expounded: viz. glass, resin-based and polymer-based; Future improvements in the preparation and use of radioactive microspheres are prospected at last. (authors)

  1. Review: microspheres for radioembolization therapy

    Energy Technology Data Exchange (ETDEWEB)

    Mingqiang, Zhao; Shuhe, Xu [China Inst. of Atomic Energy, Beijing (China)

    2007-12-15

    Radioembolization of liver cancer has been proven to be an effective therapy in nuclear medicine. The yttrium-90 glass microspheres has been used to treat both primary and metastatic liver tumors in clinic which shown encouraging results. The preparation, stability, degradation and application for medical purpose of radioactive microspheres are reviewed. At first, the theory of radioem- bolization treating cancer is discussed; and then three major radiolabled micro- sphere materials are expounded: viz. glass, resin-based and polymer-based; Future improvements in the preparation and use of radioactive microspheres are prospected at last. (authors)

  2. The behaviour of selected yttrium containing bioactive glass microspheres in simulated body environments.

    Science.gov (United States)

    Cacaina, D; Ylänen, H; Simon, S; Hupa, M

    2008-03-01

    The study aims at the manufacture and investigation of biodegradable glass microspheres incorporated with yttrium potentially useful for radionuclide therapy of cancer. The glass microspheres in the SiO2-Na2O-P2O5-CaO-K2O-MgO system containing yttrium were prepared by conventional melting and flame spheroidization. The behaviour of the yttrium silicate glass microspheres was investigated under in vitro conditions using simulated body fluid (SBF) and Tris buffer solution (TBS), for different periods of time, according to half-life time of the Y-90. The local structure of the glasses and the effect of yttrium on the biodegradability process were evaluated by Fourier Transform Infrared (FT-IR) spectroscopy and Back Scattered Electron Imaging of Scanning Electron Microscopy (BEI-SEM) equipped with Energy Dispersive X-ray (EDX) analysis. UV-VIS spectrometry and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) was used for analyzing the release behaviour of silica and yttrium in the two used solutions. The results indicate that the addition of yttrium to a bioactive glass increases its structural stability which therefore, induced a different behaviour of the glasses in simulated body environments.

  3. Y-90 SPECT ML image reconstruction with a new model for tissue-dependent bremsstrahlung production using CT information: a proof-of-concept study

    Science.gov (United States)

    Lim, Hongki; Fessler, Jeffrey A.; Wilderman, Scott J.; Brooks, Allen F.; Dewaraja, Yuni K.

    2018-06-01

    While the yield of positrons used in Y-90 PET is independent of tissue media, Y-90 SPECT imaging is complicated by the tissue dependence of bremsstrahlung photon generation. The probability of bremsstrahlung production is proportional to the square of the atomic number of the medium. Hence, the same amount of activity in different tissue regions of the body will produce different numbers of bremsstrahlung photons. Existing reconstruction methods disregard this tissue-dependency, potentially impacting both qualitative and quantitative imaging of heterogeneous regions of the body such as bone with marrow cavities. In this proof-of-concept study, we propose a new maximum-likelihood method that incorporates bremsstrahlung generation probabilities into the system matrix, enabling images of the desired Y-90 distribution to be reconstructed instead of the ‘bremsstrahlung distribution’ that is obtained with existing methods. The tissue-dependent probabilities are generated by Monte Carlo simulation while bone volume fractions for each SPECT voxel are obtained from co-registered CT. First, we demonstrate the tissue dependency in a SPECT/CT imaging experiment with Y-90 in bone equivalent solution and water. Visually, the proposed reconstruction approach better matched the true image and the Y-90 PET image than the standard bremsstrahlung reconstruction approach. An XCAT phantom simulation including bone and marrow regions also demonstrated better agreement with the true image using the proposed reconstruction method. Quantitatively, compared with the standard reconstruction, the new method improved estimation of the liquid bone:water activity concentration ratio by 40% in the SPECT measurement and the cortical bone:marrow activity concentration ratio by 58% in the XCAT simulation.

  4. Gastroretentive Floating Microspheres of Silymarin: Preparation and ...

    African Journals Online (AJOL)

    Methods: Cellulose microspheres – formulated with hydroxylpropyl methylcellulose (HPMC) and ethyl cellulose (EC) – and Eudragit microspheres – formulated with Eudragit® S 100 (ES) and Eudragit® RL (ERL) - were prepared by an emulsion-solvent evaporation method. The floating microspheres were evaluated for flow ...

  5. Evaluation of factors affecting tumor response and survival in patients with primary and metastatic liver cancer treated with microspheres.

    Science.gov (United States)

    Demirelli, Serkan; Erkilic, Metin; Oner, Ali Ozan; Budak, Evrim Surer; Gunduz, Seyda; Ozgur, Ozhan; Bozcuk, Hakan; Sindel, Hakki Timur; Boz, Adil

    2015-04-01

    Radioembolization with the yttrium-90 (Y-90) microspheres is being used increasingly more often in the treatment of patients with primary or metastatic liver cancer. Although technetium-99m macroaggregated albumin (Tc-99m MAA) scintigraphy performed following diagnostic angiography has an important role in predicting the effectiveness of treatment and in dose estimation, the number of studies using quantitative assessment of Tc-99m MAA scintigraphy is limited in this field. In the present study, the aim was to assess whether a tumor dose is required to obtain objective tumor response and to check whether this threshold value is predictive in terms of tumor response, survival, and liver toxicity by using Tc-99m MAA single-photon emission computed tomography (SPECT) images. Overall, 54 patients (20 women and 34 men; median age: 60 years) who underwent Y-90 Resin (SIR-Spheres) and Glass (TheraSphere) microsphere treatment with a diagnosis of unresectable liver cancer between August 2010 and April 2013 were included in the study. The mean doses to normal liver and tumor were estimated for each patient using Tc-99m MAA SPECT images and the medical internal radiation dosimetry method. The responses were assessed according to Response Evaluation Criteria In Solid Tumors (RECIST) and European Organisation for Research and Treatment of Cancer (EORTC) criteria. Kaplan-Meier survival curves and univariate Cox regression analysis were used in survival analysis. The relationship between treatment response and other parameters included was assessed using logistic regression analysis. The variables with a P value less than 0.01 in univariate analysis were assessed with multivariate analysis. Fifty-four Y-90 microsphere treatments (eight by using a Y-90 glass microsphere and 46 by using a Y-90 resin microsphere) were performed. In the multivariate analysis, the only parameter related to response was tumor dose (P<0.01). With a tumor dose of 280 Gy or higher, objective tumor

  6. Temperature influence in crystallinity of polymer microspheres

    International Nuclear Information System (INIS)

    Rezende, Cristiane de P.; Novack, Katia M.

    2011-01-01

    Drug delivery technology is evolving through the creation of new techniques of drug delivery effectively. The new methods used in drugs administration are based in microencapsulation process. Microsphere encapsulation modifies drug delivery bringing benefits and efficiency. In this work has been evaluated the influence of temperature in microspheres preparation. Microspheres were obtained by PMMA-co-PEG (COP) copolymer with indomethacin inserted in polymer matrix. Samples were characterized by SEM, DSC and XRD. SEM micrographs confirmed the formation of different sizes of microspheres and it was verified that higher temperatures make more crystalline microspheres. (author)

  7. Doses to the hand during the administration of radiolabeled antibodies containing Y-90, Tc-99m, I-131, and Lu-177

    Energy Technology Data Exchange (ETDEWEB)

    Barber, D.E. [Minnesota Univ., Minneapolis, MN (United States). School of Public Health; Carsten, A.L.; Kaurin, D.G.L.; Baum, J.W. [Brookhaven National Lab., Upton, NY (United States)

    1997-02-01

    Exposure of the hands of medical personnel administering radiolabeled antibodies (RABs) was evaluated on the basis of (a) observing and photo-documenting administration techniques, and (b) experimental data on doses to thermoluminescent dosimeters (TLDs) on fingers of phantom hands holding syringes, and on syringes, with radionuclides in the syringes in each case. Actual exposure data for I-131 and Lu-177 were obtained in field studies. Variations in handling and administration techniques were identified. Dose rates measured using TLDs on the surface of loaded syringes were adjusted for differences in electronic stopping power, absorption coefficients, and attenuation between dosimeters and tissue to estimate dose-to-skin averaged over 1 cm{sup 2} at 7 mg cm{sup {minus}2} depth for Y-90, Tc-99m, I-131, and Lu-177. Dose rate coefficients to the skin, if in contact with the syringe wall, were 89, 1.9, 3.8, and 0.41 {micro}Sv s{sup {minus}1} per 37 MBq (1 mCi) for Y-90, Tc-99m, I-131, and Lu-177, respectively. For dose reduction, when using Y-90 the importance was clearly indicated of (a) avoiding direct contact with syringes containing RABs, if practical, and (b) using a beta-particle shield on the syringe. In using a syringe for injection, doses can best be approximated for the geometry studied by (a) wearing a finger dosimeter on the middle finger, toward the outside of the hand, on the hand operating the plunger, and (b) wearing finger dosimeters on the inner (palm) side of the finger on the hand that supports the syringe for energetic beta-particle emitters, such as Y-90 and Re-188.

  8. Doses to the hand during the administration of radiolabeled antibodies containing Y-90, Tc-99m, I-131, and Lu-177

    International Nuclear Information System (INIS)

    Barber, D.E.

    1997-02-01

    Exposure of the hands of medical personnel administering radiolabeled antibodies (RABs) was evaluated on the basis of (a) observing and photo-documenting administration techniques, and (b) experimental data on doses to thermoluminescent dosimeters (TLDs) on fingers of phantom hands holding syringes, and on syringes, with radionuclides in the syringes in each case. Actual exposure data for I-131 and Lu-177 were obtained in field studies. Variations in handling and administration techniques were identified. Dose rates measured using TLDs on the surface of loaded syringes were adjusted for differences in electronic stopping power, absorption coefficients, and attenuation between dosimeters and tissue to estimate dose-to-skin averaged over 1 cm 2 at 7 mg cm -2 depth for Y-90, Tc-99m, I-131, and Lu-177. Dose rate coefficients to the skin, if in contact with the syringe wall, were 89, 1.9, 3.8, and 0.41 microSv s -1 per 37 MBq (1 mCi) for Y-90, Tc-99m, I-131, and Lu-177, respectively. For dose reduction, when using Y-90 the importance was clearly indicated of (a) avoiding direct contact with syringes containing RABs, if practical, and (b) using a beta-particle shield on the syringe. In using a syringe for injection, doses can best be approximated for the geometry studied by (a) wearing a finger dosimeter on the middle finger, toward the outside of the hand, on the hand operating the plunger, and (b) wearing finger dosimeters on the inner (palm) side of the finger on the hand that supports the syringe for energetic beta-particle emitters, such as Y-90 and Re-188

  9. Development of Risperidone PLGA Microspheres

    Directory of Open Access Journals (Sweden)

    Susan D’Souza

    2014-01-01

    Full Text Available The aim of this study was to design and evaluate biodegradable PLGA microspheres for sustained delivery of Risperidone, with an eventual goal of avoiding combination therapy for the treatment of schizophrenia. Two PLGA copolymers (50 : 50 and 75 : 25 were used to prepare four microsphere formulations of Risperidone. The microspheres were characterized by several in vitro techniques. In vivo studies in male Sprague-Dawley rats at 20 and 40 mg/kg doses revealed that all formulations exhibited an initial burst followed by sustained release of the active moiety. Additionally, formulations prepared with 50 : 50 PLGA had a shorter duration of action and lower cumulative AUC levels than the 75 : 25 PLGA microspheres. A simulation of multiple dosing at weekly or 15-day regimen revealed pulsatile behavior for all formulations with steady state being achieved by the second dose. Overall, the clinical use of Formulations A, B, C, or D will eliminate the need for combination oral therapy and reduce time to achieve steady state, with a smaller washout period upon cessation of therapy. Results of this study prove the suitability of using PLGA copolymers of varying composition and molecular weight to develop sustained release formulations that can tailor in vivo behavior and enhance pharmacological effectiveness of the drug.

  10. Preparing microspheres of actinide nitrides from carbon containing oxide sols

    International Nuclear Information System (INIS)

    Triggiani, L.V.

    1975-01-01

    A process is given for preparing uranium nitride, uranium oxynitride, and uranium carboxynitride microspheres and the microspheres as compositions of matter. The microspheres are prepared from carbide sols by reduction and nitriding steps. (Official Gazette)

  11. Chitosan Microspheres as Radiolabeled Delivery Devices

    International Nuclear Information System (INIS)

    Permtermsin, Chalermsin; Ngamprayad, Tippanan; Phumkhem, Sudkanung; Srinuttrakul, Wannee; Kewsuwan, Prartana

    2007-08-01

    Full text: This study optimized conditions for preparing, characterizing, radiolabeled of chitosan microspheres and the biodistribution of 99mTc-Chitosan microspheres after intravenous administration. Particle size distribution of the microspheres was determined by light scattering. Zeta potential was studied by dynamic light scattering and electrophoresis technique. Biodistribution studies were performed by radiolabeling using 99mTc. The results shown that geometric mean diameter of the microspheres was found to be 77.26?1.96 ?m. Microsphere surface charge of chitosan microspheres was positive charge and zeta potential was 25.80 ? 0.46 mV. The labeling efficiency for this condition was more than 95% and under this condition was stable for at least 6 h. Radioactivity

  12. In vitro Evaluation of Nateglinide-Loaded Microspheres Formulated ...

    African Journals Online (AJOL)

    Keywords: Nateglinide, Microspheres, Micromeritics, Drug release, Ionic ... Oral drug delivery systems (DDS) are commonly divided into immediate release and modified release systems. ..... Albumin Microspheres for Potential Intramuscular.

  13. Evaluation of radiolabelled microspheres as digesta markers

    International Nuclear Information System (INIS)

    Young, B.A.; Turner, B.V.; Dixon, A.E.; Exley, D.M.; Young, S.B.; Abidin, Z.

    1991-01-01

    The suitability of microspheres as markers for measuring digesta kinetics in sheep was examined. Microspheres offer advantages of uniformity of size and density, and stability during passage through the gastrointestinal tract. They are commercially available labelled with the choice of one of eleven different radionuclides and can be easily measured in digesta and faecal material. Tests comparing several types of digesta markers gave different measures of kinetic parameters when the measurements were made concurrently in the same sheep. However, concurrent measurements derived from use of microspheres were consistent. Microspheres offer a new alternative for digestive studies. (author). 19 refs, 4 tabs

  14. [Preoperative structured patient education].

    Science.gov (United States)

    Lamarche, D

    1993-04-01

    This article describes the factors that motivated the nursing staff of the cardiac surgery unit at the Royal Victoria Hospital in Montreal, to revise their preoperative teaching program. The motivating factors described are the length of the preoperative waiting period; the level of preoperative anxiety; the decreased length of hospital stay; the dissatisfaction of the nursing staff with current patient teaching practices; and the lack of available resources. The reorganization of the teaching program was based upon the previously described factors combined with a review of the literature that demonstrated the impact of preoperative anxiety, emotional support and psycho-educational interventions upon the client's recovery. The goals of the new teaching program are to provide the client and the family with cognitive and sensory information about the client's impending hospitalization, chronic illness and necessary lifestyle modifications. The program consists of a system of telephone calls during the preoperative waiting period; a videotape viewing; a tour of the cardiac surgery unit; informal discussion groups; and the availability of nursing consultation to decrease preoperative anxiety. The end result of these interventions is more time for client support and integration of necessary information by the client and family. This kind of program has the potential to provide satisfaction at many levels by identifying client's at risk; increasing client knowledge; increasing support; decreasing anxiety during the preoperative waiting period; and decreasing the length of hospital stay. The nursing staff gained a heightened sense of accomplishment because the program was developed according to the nursing department's philosophy, which includes primary nursing.(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Glass microspheres for medical applications

    Science.gov (United States)

    Conzone, Samuel David

    Radioactive dysprosium lithium borate glass microspheres have been developed as biodegradable radiation delivery vehicles for the radiation synovectomy treatment of rheumatoid arthritis. Once injected into a diseased joint, the microspheres deliver a potent dose of radiation to the diseased tissue, while a non-uniform chemical reaction converts the glass into an amorphous, porous, hydrated dysprosium phosphate reaction product. The non-radioactive, lithium-borate component is dissolved from the glass (up to 94% weight loss), while the radioactive 165Dy reacts with phosphate anions in the body fluids, and becomes "chemically" trapped in a solid, dysprosium phosphate reaction product that has the same size as the un-reacted glass microsphere. Ethylene diamine tetraacetate (EDTA) chelation therapy can be used to dissolve the dysprosium phosphate reaction product after the radiation delivery has subsided. The dysprosium phosphate reaction product, which formed in vivo in the joint of a Sprague-Dawley rat, was dissolved by EDTA chelation therapy in 100 Gy) of localized beta radiation to a treatment site within the body, followed by complete biodegradability. The non-uniform reaction process is a desirable characteristic for a biodegradable radiation delivery vehicle, but it is also a novel material synthesis technique that can convert a glass to a highly porous materials with widely varying chemical composition by simple, low-temperature, glass/solution reaction. The reaction product formed by nonuniform reaction occupies the same volume as the un-reacted glass, and after drying for 1 h at 300°C, has a specific surface area of ≈200 m2/g, a pore size of ≈30 nm, and a nominal crushing strength of ≈10 MPa. Finally, rhenium glass microspheres, composed of micron-sized, metallic rhenium particles dispersed within a magnesium alumino borate glass matrix were produced by sintering ReO2 powder and glass frit at 1050°C. A 50 mg injection of radioactive rhenium glass

  16. Immediate preoperative enteral nutrition (preoperative enteral nutrition

    Directory of Open Access Journals (Sweden)

    Lađević Nebojša

    2017-01-01

    Full Text Available Nutritional support of surgical patients is a necessary part of the treatment. It alone cannot cure the disease but it significantly affects the recovery of patients and supports surgical interventions. Patients in malnutrition have shown to have significantly more postoperative infectious and non-infectious complications. This significantly prolongs treatment time and increases costs. However, there is one fact that cannot be expressed in money, which is the patient's impression of the surgical intervention. Adequate preoperative patient support, based on the intake of liquid nutritive solutions, reduces preoperative stress and deflects the metabolic response. Now, it is recommended for adults and children older than one year to drink clear liquid up to 2 hours before induction in anesthesia. Appropriate enteral nutrition has a significant place in the postoperative recovery of patients. Enteral nutrition is reducing complications, mainly infectious complications because the function of the digestive system as one large immune system is preserved. Perioperative enteral nutrition is a necessary part of the modern treatment of surgical patients. In addition to the significant effect on the occurrence of postoperative complications, it is also important that this type of diet improves the psychological status of patients.

  17. Microsphere estimates of blood flow: Methodological considerations

    International Nuclear Information System (INIS)

    von Ritter, C.; Hinder, R.A.; Womack, W.; Bauerfeind, P.; Fimmel, C.J.; Kvietys, P.R.; Granger, D.N.; Blum, A.L.

    1988-01-01

    The microsphere technique is a standard method for measuring blood flow in experimental animals. Sporadic reports have appeared outlining the limitations of this method. In this study the authors have systematically assessed the effect of blood withdrawals for reference sampling, microsphere numbers, and anesthesia on blood flow estimates using radioactive microspheres in dogs. Experiments were performed on 18 conscious and 12 anesthetized dogs. Four blood flow estimates were performed over 120 min using 1 x 10 6 microspheres each time. The effects of excessive numbers of microspheres pentobarbital sodium anesthesia, and replacement of volume loss for reference samples with dextran 70 were assessed. In both conscious and anesthetized dogs a progressive decrease in gastric mucosal blood flow and cardiac output was observed over 120 min. This was also observed in the pancreas in conscious dogs. The major factor responsible for these changes was the volume loss due to the reference sample withdrawals. Replacement of the withdrawn blood with dextran 70 led to stable blood flows to all organs. The injection of excessive numbers of microspheres did not modify hemodynamics to a greater extent than did the injection of 4 million microspheres. Anesthesia exerted no influence on blood flow other than raising coronary flow. The authors conclude that although blood flow to the gastric mucosa and the pancreas is sensitive to the minor hemodynamic changes associated with the microsphere technique, replacement of volume loss for reference samples ensures stable blood flow to all organs over a 120-min period

  18. Thermal analysis of iron hydroxide microspheres

    International Nuclear Information System (INIS)

    Turcanu, C.N.; Cornescu, M.

    1979-03-01

    The thermal treatment is an important step in the preparative technology of the iron oxids microspheres with well established mechanical, physical and chemical characteristics. The first indications on the heating procedure have been obtained from the thermal analysis on iron hydroxide microspheres prepared by the support precipitation and internal gelification methods. (author)

  19. Encapsulated PDMS microspheres with reactive handles

    DEFF Research Database (Denmark)

    Gonzalez, Lidia; Ma, Baoguang; Li, Li

    2014-01-01

    , cured PDMS microspheres are coated with poly(methyl methacrylate) using a chemical process (solvent evaporation technique). Three solvents are used in three different experiments: dichloromethane, tetrahydrofuran, and acetone. The composition and morphology of the cured PDMS microspheres and PMMA coated...

  20. Microencapsulation and microspheres for food applications

    NARCIS (Netherlands)

    Sagis, L.M.C.

    2015-01-01

    This book provides an update on the latest developments, challenges, and opportunities in the highly expanding field of microencapsulation and microspheres for food applications, examining the various types of microspheres and microcapsules essential to those who need to develop stable and

  1. U3O8 microspheres sintering kinetics

    International Nuclear Information System (INIS)

    Godoy, A.L.E.

    1986-01-01

    U 3 O 8 microspheres sintering kinetics was determined using a hot-stage optical microscopy apparatus, able to reach temperature up to 1350 0 C in controlled atmospheres. The sintered material had its microstructure analysed by optical and electron microscopy. The microspheres were characterized initialy utilizing X-ray diffractometry and thermogravimetry. The equation which describes the microspheres shrinkage in function of the time was obtained using finite difference analysis X-ray diffractometry indicated hexagonal structure for the microspheres main starting material, ammonium diuranate thermogravimetric analysis showed reduction of this material to U 3 O 8 at 600 0 C. Ceramography results showed 5 hours sintered microspheres grain sizes G vary with the temperature. Sintered U 3 O 8 micrographs compared with published results for UO 2 , indicate similar homogeneity microstructural characteristics and suggest the processed micorspheres to be potentially useful as nuclear fuels. (Author) [pt

  2. Magnetic susceptibility characterisation of superparamagnetic microspheres

    Science.gov (United States)

    Grob, David Tim; Wise, Naomi; Oduwole, Olayinka; Sheard, Steve

    2018-04-01

    The separation of magnetic materials in microsystems using magnetophoresis has increased in popularity. The wide variety and availability of magnetic beads has fuelled this drive. It is important to know the magnetic characteristics of the microspheres in order to accurately use them in separation processes integrated on a lab-on-a-chip device. To investigate the magnetic susceptibility of magnetic microspheres, the magnetic responsiveness of three types of Dynabeads microspheres were tested using two different approaches. The magnetophoretic mobility of individual microspheres is studied using a particle tracking system and the magnetization of each type of Dynabeads microsphere is measured using SQUID relaxometry. The magnetic beads' susceptibility is obtained at four different applied magnetic fields in the range of 38-70 mT for both the mobility and SQUID measurements. The susceptibility values in both approaches show a consistent magnetic field dependence.

  3. [Preoperative fasting. An update].

    Science.gov (United States)

    Spies, C D; Breuer, J P; Gust, R; Wichmann, M; Adolph, M; Senkal, M; Kampa, U; Weissauer, W; Schleppers, A; Soreide, E; Martin, E; Kaisers, U; Falke, K J; Haas, N; Kox, W J

    2003-11-01

    In Germany the predominant standard of preoperative care for elective surgery is fasting after midnight, with the aim of reducing the risk of pulmonary aspiration. However, for the past several years the scientific evidence supporting such a practice has been challenged. Experimental and clinical studies prove a reliable gastric emptying within 2 h suggesting that, particularly for limited intake of clear fluids up to 2 h preoperatively, there would be no increased risk for the patient. In addition, the general incidence of pulmonary aspiration during general anaesthesia (before induction, during surgery and during recovery) is extremely low, has a good prognosis and is more a consequence of insufficient airway protection and/or inadequate anaesthetic depth rather than due to the patient's fasting state. Therefore, primarily to decrease perioperative discomfort for patients, several national anaesthesia societies have changed their guidelines for preoperative fasting. They recommend a more liberal policy regarding per os intake of both liquid and solid food, with consideration of certain conditions and contraindications. The following article reviews the literature and gives an overview of the scientific background on which the national guidelines are based. The intention of this review is to propose recommendations for preoperative fasting regarding clear fluids for Germany as well.

  4. Interventions for preoperative smoking cessation

    DEFF Research Database (Denmark)

    Møller, A; Villebro, N

    2005-01-01

    Smokers have a substantially increased risk of intra- and postoperative complications. Preoperative smoking intervention may be effective in decreasing this incidence. The preoperative period may be a well chosen time to offer smoking cessation interventions due to increased patient motivation....

  5. Progress in Preparation of Monodisperse Polymer Microspheres

    Science.gov (United States)

    Zhang, Hongyan

    2017-12-01

    The monodisperse crosslinked polymer microspheres have attracted much attention because of their superior thermal and solvent resistance, mechanical strength, surface activity and adsorption properties. They are of wide prospects for using in many fields such as biomedicine, electronic science, information technology, analytical chemistry, standard measurement and environment protection etc. Functional polymer microspheres prepared by different methods have the outstanding surface property, quantum size effect and good potential future in applications with its designable structure, controlled size and large ratio of surface to volume. Scholars of all over the world have focused on this hot topic. The preparation method and research progress in functional polymer microspheres are addressed in the paper.

  6. Preoperative bone scans

    International Nuclear Information System (INIS)

    Charkes, N.D.; Malmud, L.S.; Caswell, T.; Goldman, L.; Hall, J.; Lauby, V.; Lightfoot, W.; Maier, W.; Rosemond, G.

    1975-01-01

    Strontium nitrate Sr-87m bone scans were made preoperatively in a group of women with suspected breast cancer, 35 of whom subsequently underwent radical mastectomy. In 3 of the 35 (9 percent), the scans were abnormal despite the absence of clinical or roentgenographic evidence of metastatic disease. All three patients had extensive axillary lymph node involvement by tumor, and went on to have additional bone metastases, from which one died. Roentgenograms failed to detect the metastases in all three. Occult bone metastases account in part for the failure of radical mastectomy to cure some patients with breast cancer. It is recommended that all candidates for radical mastectomy have a preoperative bone scan. (U.S.)

  7. Absorbed dose kernel and self-shielding calculations for a novel radiopaque glass microsphere for transarterial radioembolization.

    Science.gov (United States)

    Church, Cody; Mawko, George; Archambault, John Paul; Lewandowski, Robert; Liu, David; Kehoe, Sharon; Boyd, Daniel; Abraham, Robert; Syme, Alasdair

    2018-02-01

    Radiopaque microspheres may provide intraprocedural and postprocedural feedback during transarterial radioembolization (TARE). Furthermore, the potential to use higher resolution x-ray imaging techniques as opposed to nuclear medicine imaging suggests that significant improvements in the accuracy and precision of radiation dosimetry calculations could be realized for this type of therapy. This study investigates the absorbed dose kernel for novel radiopaque microspheres including contributions of both short and long-lived contaminant radionuclides while concurrently quantifying the self-shielding of the glass network. Monte Carlo simulations using EGSnrc were performed to determine the dose kernels for all monoenergetic electron emissions and all beta spectra for radionuclides reported in a neutron activation study of the microspheres. Simulations were benchmarked against an accepted 90 Y dose point kernel. Self-shielding was quantified for the microspheres by simulating an isotropically emitting, uniformly distributed source, in glass and in water. The ratio of the absorbed doses was scored as a function of distance from a microsphere. The absorbed dose kernel for the microspheres was calculated for (a) two bead formulations following (b) two different durations of neutron activation, at (c) various time points following activation. Self-shielding varies with time postremoval from the reactor. At early time points, it is less pronounced due to the higher energies of the emissions. It is on the order of 0.4-2.8% at a radial distance of 5.43 mm with increased size from 10 to 50 μm in diameter during the time that the microspheres would be administered to a patient. At long time points, self-shielding is more pronounced and can reach values in excess of 20% near the end of the range of the emissions. Absorbed dose kernels for 90 Y, 90m Y, 85m Sr, 85 Sr, 87m Sr, 89 Sr, 70 Ga, 72 Ga, and 31 Si are presented and used to determine an overall kernel for the

  8. Evaluation of Controlled Release Theophylline Microspheres ...

    African Journals Online (AJOL)

    Erah

    High drug/polymer ratio, low processing temperature and low HLB value of ... Keywords: Microsphere, Emulsion solvent evaporation, Theophylline, Temperature, ... evaporation, stirring rate, viscosity of ... organic solvent is removed from the.

  9. PLGA/alginate composite microspheres for hydrophilic protein delivery

    International Nuclear Information System (INIS)

    Zhai, Peng; Chen, X.B.; Schreyer, David J.

    2015-01-01

    Poly(lactic-co-glycolic acid) (PLGA) microspheres and PLGA/alginate composite microspheres were prepared by a novel double emulsion and solvent evaporation technique and loaded with bovine serum albumin (BSA) or rabbit anti-laminin antibody protein. The addition of alginate and the use of a surfactant during microsphere preparation increased the encapsulation efficiency and reduced the initial burst release of hydrophilic BSA. Confocal laser scanning microcopy (CLSM) of BSA-loaded PLGA/alginate composite microspheres showed that PLGA, alginate, and BSA were distributed throughout the depths of microspheres; no core/shell structure was observed. Scanning electron microscopy revealed that PLGA microspheres erode and degrade more quickly than PLGA/alginate composite microspheres. When loaded with anti-laminin antibody, the function of released antibody was well preserved in both PLGA and PLGA/alginate composite microspheres. The biocompatibility of PLGA and PLGA/alginate microspheres were examined using four types of cultured cell lines, representing different tissue types. Cell survival was variably affected by the inclusion of alginate in composite microspheres, possibly due to the sensitivity of different cell types to excess calcium that may be released from the calcium cross-linked alginate. - Highlights: • A double emulsion technique is used to prepare protein-loaded PLGA or PLGA/alginate microspheres. • PLGA, alginate and protein are distributed evenly within microsphere structure. • Addition of alginate improves loading efficiency and slows degradation and protein release. • PLGA/alginate microspheres have favorable biocompatibility

  10. PLGA/alginate composite microspheres for hydrophilic protein delivery

    Energy Technology Data Exchange (ETDEWEB)

    Zhai, Peng [Department of Anatomy and Cell Biology, University of Saskatchewan, S7N5E5 (Canada); Division of Biomedical Engineering, University of Saskatchewan, S7N5A9 (Canada); Chen, X.B. [Department of Mechanical Engineering, University of Saskatchewan, S7N5A9 (Canada); Division of Biomedical Engineering, University of Saskatchewan, S7N5A9 (Canada); Schreyer, David J., E-mail: david.schreyer@usask.ca [Department of Anatomy and Cell Biology, University of Saskatchewan, S7N5E5 (Canada); Division of Biomedical Engineering, University of Saskatchewan, S7N5A9 (Canada)

    2015-11-01

    Poly(lactic-co-glycolic acid) (PLGA) microspheres and PLGA/alginate composite microspheres were prepared by a novel double emulsion and solvent evaporation technique and loaded with bovine serum albumin (BSA) or rabbit anti-laminin antibody protein. The addition of alginate and the use of a surfactant during microsphere preparation increased the encapsulation efficiency and reduced the initial burst release of hydrophilic BSA. Confocal laser scanning microcopy (CLSM) of BSA-loaded PLGA/alginate composite microspheres showed that PLGA, alginate, and BSA were distributed throughout the depths of microspheres; no core/shell structure was observed. Scanning electron microscopy revealed that PLGA microspheres erode and degrade more quickly than PLGA/alginate composite microspheres. When loaded with anti-laminin antibody, the function of released antibody was well preserved in both PLGA and PLGA/alginate composite microspheres. The biocompatibility of PLGA and PLGA/alginate microspheres were examined using four types of cultured cell lines, representing different tissue types. Cell survival was variably affected by the inclusion of alginate in composite microspheres, possibly due to the sensitivity of different cell types to excess calcium that may be released from the calcium cross-linked alginate. - Highlights: • A double emulsion technique is used to prepare protein-loaded PLGA or PLGA/alginate microspheres. • PLGA, alginate and protein are distributed evenly within microsphere structure. • Addition of alginate improves loading efficiency and slows degradation and protein release. • PLGA/alginate microspheres have favorable biocompatibility.

  11. DEGRADATION AND INTRAHEPATIC COMPATIBILITY OF ALBUMIN-HEPARIN CONJUGATE MICROSPHERES

    NARCIS (Netherlands)

    CREMERS, HFM; WOLF, RFE; BLAAUW, EH; SCHAKENRAAD, JM; LAM, KH; NIEUWENHUIS, P; VERRIJK, R; KWON, G; BAE, YH; KIM, SW; FEIJEN, J

    The in vitro degradation properties of glutaraldehyde cross-linked albumin and albumin-heparin conjugate microspheres (AMS and AHCMS respectively) were evaluated using light microscopy, turbidity measurements and heparin release determinations, showing that the microspheres are degraded by

  12. Biocompatibility of Polyhydroxybutyrate Microspheres: in vitro and in vivo Evaluation

    OpenAIRE

    Shishatskaya, Ekaterina I.; Voinova, Olga N.; Goreva, Anastasya V.; Mogilnaya, Olga A.; Volova, Tatiana G.

    2008-01-01

    Microspheres have been prepared from the resorbable linear polyester of β-hydroxybutyric acid (polyhydroxybutyrate, PHB) by the solvent evaporation technique and investigated in vitro and in vivo. Biocompatibility of the microspheres has been proved in tests in the culture of mouse fibroblast cell line NIH 3Т3 and in experiments on intramuscular implantation of the microspheres to Wistar rats for 3 months. Tissue response to the implantation of polymeric microspheres has been found to consist...

  13. Preparation and Characterization of Sugar Cane Wax Microspheres ...

    African Journals Online (AJOL)

    ... and characterize indomethacin (IM) microspheres prepared with sugar cane wax microsperes. Methods: Microspheres were prepared by melt-emulsified dispersion and cooling-induced solidification method. The microspheres were characterized by scanning electron microscopy (SEM) and differntial scanning calorimetry ...

  14. Preparation of polymer microspheres by radiation-induced polymerization

    International Nuclear Information System (INIS)

    Naka, Y.; Yamamoto, Y.; Yoshida, Y.; Tagawa, S.

    1995-01-01

    Cross-liking monomer, diethylene glycol dimethacrylate gives microspheres from organic solution by radiation-induced polymerization. /One of the remarkable result is that the number of the microspheres is not changing during the polymerization. Ethyl methacrylate, maleic anhydride, styrene and acrylamide are used as comonomers. These comonomers give the microspheres in the range of 0 to 0.4 as mol fractions. (author)

  15. Adopting preoperative fasting guidelines.

    Science.gov (United States)

    Anderson, Megan; Comrie, Rhonda

    2009-07-01

    In 1999, the American Society of Anesthesiologists adopted preoperative fasting guidelines to enhance the quality and efficiency of patient care. Guidelines suggest that healthy, non-pregnant patients should fast six hours from solids and two hours from liquids. Although these guidelines are in place, studies suggest that providers are still using the blanket statement "NPO after midnight" without regard to patient characteristics, the procedure, or the time of the procedure. Using theory to help change provider's beliefs may help make change more successful. Rogers' Theory of Diffusion of Innovations can assist in changing long-time practice by laying the groundwork for an analysis of the benefits and disadvantages of proposed changes, such as changes to fasting orders, while helping initiate local protocols instead of additional national guidelines.

  16. Flexible Microsphere-Embedded Film for Microsphere-Enhanced Raman Spectroscopy.

    Science.gov (United States)

    Xing, Cheng; Yan, Yinzhou; Feng, Chao; Xu, Jiayu; Dong, Peng; Guan, Wei; Zeng, Yong; Zhao, Yan; Jiang, Yijian

    2017-09-27

    Dielectric microspheres with extraordinary microscale optical properties, such as photonic nanojets, optical whispering-gallery modes (WGMs), and directional antennas, have drawn interest in many research fields. Microsphere-enhanced Raman spectroscopy (MERS) is an alternative approach for enhanced Raman detection by dielectric microstructures. Unfortunately, fabrication of microsphere monolayer arrays is the major challenge of MERS for practical applications on various specimen surfaces. Here we report a microsphere-embedded film (MF) by immersing a highly refractive microsphere monolayer array in the poly(dimethylsiloxane) (PDMS) film as a flexible MERS sensing platform for one- to three-dimensional (1D to 3D) specimen surfaces. The directional antennas and wave-guided whispering-gallery modes (WG-WGMs) contribute to the majority of Raman enhancement by the MFs. Moreover, the MF can be coupled with surface-enhanced Raman spectroscopy (SERS) to provide an extra >10-fold enhancement. The limit of detection is therefore improved for sensing of crystal violet (CV) and Sudan I molecules in aqueous solutions at concentrations down to 10 -7 M. A hybrid dual-layer microsphere enhancer, constructed by depositing a MF onto a microsphere monolayer array, is also demonstrated, wherein the WG-WGMs become dominant and boost the enhancement ratio >50-fold. The present work opens up new opportunities for design of cost-effective and flexible MERS sensing platforms as individual or associated techniques toward practical applications in ultrasensitive Raman detection.

  17. Biosensing by WGM Microspherical Resonators

    Directory of Open Access Journals (Sweden)

    Giancarlo C. Righini

    2016-06-01

    Full Text Available Whispering gallery mode (WGM microresonators, thanks to their unique properties, have allowed researchers to achieve important results in both fundamental research and engineering applications. Among the various geometries, microspheres are the simplest 3D WGM resonators; the total optical loss in such resonators can be extremely low, and the resulting extraordinarily high Q values of 108–109 lead to high energy density, narrow resonant-wavelength lines and a lengthy cavity ringdown. They can also be coated in order to better control their properties or to increase their functionality. Their very high sensitivity to changes in the surrounding medium has been exploited for several sensing applications: protein adsorption, trace gas detection, impurity detection in liquids, structural health monitoring of composite materials, detection of electric fields, pressure sensing, and so on. In the present paper, after a general introduction to WGM resonators, attention is focused on spherical microresonators, either in bulk or in bubble format, to their fabrication, characterization and functionalization. The state of the art in the area of biosensing is presented, and the perspectives of further developments are discussed.

  18. Occupational exposure following Yttrium-90 microspheres SIR therapy

    International Nuclear Information System (INIS)

    Fontaine, P.; Boirie, G.; Dieudonne, A.; Leguludec, D.; Lebtahi, R.; Ben Reguiga, M.

    2015-01-01

    Full text of publication follows. Introduction: Selective Internal Radiation Therapy (SIRT) is a promising technique for solid hepatic neoplasms treatment. SIRT consists in implanting radioactive microspheres (RMS) in targeted hepatic lesions via femoral artery. Two RMS-Therapsheres [glass-microspheres/TSR] and Sir-Spheres [resin-spheres/SSR]- are marketed in the European market, both radiolabeled with Yttrium-90. The objective of this study is to assess occupational exposure for nuclear medicine, radiology and clinical staff involved in Y 90 -RMS preparation and implantation. Materials and methods: The study was conducted on 20 patients treated for Hepato-Cellular Carcinoma: 10 treated with TSR and 10 with SSR. Dose rate (DR, mSv/h) or absorbed doses (mSv) measurements were made during all steps of TSR and SSR handling: sources receipt and unpacking, preparation, transport to radiology, implantation, and patient care. Measurements were made with portable ionization chamber(Babyline/Nardeux), spectrometer(FieldSpect/Aries), digital dosimeter (NED/Unfors) and operational dosimeter (Mk2/Siemens). Values were expressed as mean±SD. Results: patients received of 1.8 GBq to 3.1 GBq of TSR and 0.55 GBq to 2.4 GBq of SSR. TSR were delivered ready-to-use with the prescribed activity. For SSR only one activity was commercially available and shipped (3 GBq at calibration-time)requiring a preparation step to adjust needed activity. DR measured during RMS was 1723 ± 157 μSv/h SSR and 1189 ± 92 μSv/h for TSR. When preparing spheres in radiopharmacy, fingers and whole body doses were respectively 8326 ± 2360 μSv and 12.3 ± 5,2 μSv for Sir-Spheres vs. 33.5 ± 7.8 μSv and 1.1 ± 0.3 μSv for TSR. DR in contact with carrying case during RMS transfer to radiology were 299 ± 102 μSv/h for SSR and 5.3 ± 1.2 μSv/h for TSR. During RMS infusion, radiologist's finger doses were limited to 3.6 ± 1 μSv for SSR and 0.7± 0.3 μSv for TSR. Finally, following RMS

  19. Hydrogen transport and storage in engineered glass microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Rambach, G.D.

    1995-04-18

    New, high strength glass microspheres filled with pressurized hydrogen exhibit densities which make them attractive for bulk hydrogen storage and transport. The membrane tensile stress at failure for our engineered glass microspheres is about 150,000 psi, permitting a threefold increase in pressure limit and storage capacity above commercial microspheres, which have been studied a decade ago and have been shown to fail at membrane stresses of 50,000 psi. Our analysis relating glass microspheres for hydrogen transport with infrastructure and economics, indicate that pressurized microspheres can be economically competitive with other forms of bulk rail and truck transport such as pressurized tube transports and liquid hydrogen trailers.

  20. A method for energy window optimization for quantitative tasks that includes the effects of model-mismatch on bias: application to Y-90 bremsstrahlung SPECT imaging

    International Nuclear Information System (INIS)

    Rong Xing; Du Yong; Frey, Eric C

    2012-01-01

    Quantitative Yttrium-90 ( 90 Y) bremsstrahlung single photon emission computed tomography (SPECT) imaging has shown great potential to provide reliable estimates of 90 Y activity distribution for targeted radionuclide therapy dosimetry applications. One factor that potentially affects the reliability of the activity estimates is the choice of the acquisition energy window. In contrast to imaging conventional gamma photon emitters where the acquisition energy windows are usually placed around photopeaks, there has been great variation in the choice of the acquisition energy window for 90 Y imaging due to the continuous and broad energy distribution of the bremsstrahlung photons. In quantitative imaging of conventional gamma photon emitters, previous methods for optimizing the acquisition energy window assumed unbiased estimators and used the variance in the estimates as a figure of merit (FOM). However, for situations, such as 90 Y imaging, where there are errors in the modeling of the image formation process used in the reconstruction there will be bias in the activity estimates. In 90 Y bremsstrahlung imaging this will be especially important due to the high levels of scatter, multiple scatter, and collimator septal penetration and scatter. Thus variance will not be a complete measure of reliability of the estimates and thus is not a complete FOM. To address this, we first aimed to develop a new method to optimize the energy window that accounts for both the bias due to model-mismatch and the variance of the activity estimates. We applied this method to optimize the acquisition energy window for quantitative 90 Y bremsstrahlung SPECT imaging in microsphere brachytherapy. Since absorbed dose is defined as the absorbed energy from the radiation per unit mass of tissues in this new method we proposed a mass-weighted root mean squared error of the volume of interest (VOI) activity estimates as the FOM. To calculate this FOM, two analytical expressions were derived for

  1. A method for energy window optimization for quantitative tasks that includes the effects of model-mismatch on bias: application to Y-90 bremsstrahlung SPECT imaging.

    Science.gov (United States)

    Rong, Xing; Du, Yong; Frey, Eric C

    2012-06-21

    Quantitative Yttrium-90 ((90)Y) bremsstrahlung single photon emission computed tomography (SPECT) imaging has shown great potential to provide reliable estimates of (90)Y activity distribution for targeted radionuclide therapy dosimetry applications. One factor that potentially affects the reliability of the activity estimates is the choice of the acquisition energy window. In contrast to imaging conventional gamma photon emitters where the acquisition energy windows are usually placed around photopeaks, there has been great variation in the choice of the acquisition energy window for (90)Y imaging due to the continuous and broad energy distribution of the bremsstrahlung photons. In quantitative imaging of conventional gamma photon emitters, previous methods for optimizing the acquisition energy window assumed unbiased estimators and used the variance in the estimates as a figure of merit (FOM). However, for situations, such as (90)Y imaging, where there are errors in the modeling of the image formation process used in the reconstruction there will be bias in the activity estimates. In (90)Y bremsstrahlung imaging this will be especially important due to the high levels of scatter, multiple scatter, and collimator septal penetration and scatter. Thus variance will not be a complete measure of reliability of the estimates and thus is not a complete FOM. To address this, we first aimed to develop a new method to optimize the energy window that accounts for both the bias due to model-mismatch and the variance of the activity estimates. We applied this method to optimize the acquisition energy window for quantitative (90)Y bremsstrahlung SPECT imaging in microsphere brachytherapy. Since absorbed dose is defined as the absorbed energy from the radiation per unit mass of tissues in this new method we proposed a mass-weighted root mean squared error of the volume of interest (VOI) activity estimates as the FOM. To calculate this FOM, two analytical expressions were

  2. A microsphere suspension model of metamaterial fluids

    Directory of Open Access Journals (Sweden)

    Qian Duan

    2017-05-01

    Full Text Available Drawing an analogy to the liquid phase of natural materials, we theoretically propose a microsphere suspension model to realize a metamaterial fluid with artificial electromagnetic indexes. By immersing high-ε, micrometer-sized dielectric spheres in a low-ε insulating oil, the structured fluid exhibits liquid-like properties from dispersing phase as well as the isotropic negative electromagnetic parameters caused by Mie resonances from dispersed microspheres. The work presented here will benefit the development of structured fluids toward metamaterials.

  3. Albumin microspheres labeled with Ga-67 by chelation: concise communication

    International Nuclear Information System (INIS)

    Hnatowich, D.J.; Schlegel, P.

    1981-01-01

    Albumin microspheres have been synthesized with EDTA and DTPA chelating groups covalently bound to their surface. The microspheres may be labeled with Ga-67 at high yield (97 +- 2%) by transcomplexation from a 0.1 M Ga-67 acetate solution. With EDTA microspheres the resulting label dissociates only slightly after 24 hr in 50% plasma at 37 0 C, whereas with DTPA microspheres the label shows no detectable dissociation over this period. By contrast, microspheres without chelating groups lose their label virtually completely under these conditions. Following intravenous administration of sized Ga-67 DTPA microspheres in mice, about (84 +- 16)% of the activity localizes in the lungs at 5 min, with (60 +- 7)% remaining after 2 h. Since labeling is by chelation, the microspheres may also be tagged with other metallic radionuclides

  4. Successful Preoperative Chemoembolization in the Treatment of a Giant Malignant Phyllodes Tumor

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Kazuki, E-mail: kazkik1980@gmail.com; Mimura, Hidefumi; Arai, Yasunori [St. Marianna University School of Medicine, Department of Radiology (Japan); Doi, Masatomo [St. Marianna University School of Medicine, Department of Pathology (Japan); Kojima, Yasuyuki; Tsugawa, Koichiro [St. Marianna University School of Medicine, Division of Breast and Endocrine Surgery, Department of Surgery (Japan); Nakajima, Yasuo [St. Marianna University School of Medicine, Department of Radiology (Japan)

    2016-07-15

    The malignant phyllodes tumor is a relatively rare neoplasm and has not previously been a therapeutic target of interventional radiology. Herein, we report a successful case of preoperative chemoembolization of a giant malignant phyllodes tumor. The objective was to achieve sufficient tumor shrinkage before surgery to avoid the requirement for skin grafting after resection. Intra-arterial epirubicin infusion and subsequent embolization with Embosphere Microspheres (BioSphere Medical, Rockland, MA, USA) was undertaken three times over the course of 6 weeks and was well tolerated. The patient underwent surgery without skin grafting. Neither local recurrence nor distant metastasis was observed at 6 months after surgery.

  5. Successful Preoperative Chemoembolization in the Treatment of a Giant Malignant Phyllodes Tumor

    International Nuclear Information System (INIS)

    Hashimoto, Kazuki; Mimura, Hidefumi; Arai, Yasunori; Doi, Masatomo; Kojima, Yasuyuki; Tsugawa, Koichiro; Nakajima, Yasuo

    2016-01-01

    The malignant phyllodes tumor is a relatively rare neoplasm and has not previously been a therapeutic target of interventional radiology. Herein, we report a successful case of preoperative chemoembolization of a giant malignant phyllodes tumor. The objective was to achieve sufficient tumor shrinkage before surgery to avoid the requirement for skin grafting after resection. Intra-arterial epirubicin infusion and subsequent embolization with Embosphere Microspheres (BioSphere Medical, Rockland, MA, USA) was undertaken three times over the course of 6 weeks and was well tolerated. The patient underwent surgery without skin grafting. Neither local recurrence nor distant metastasis was observed at 6 months after surgery.

  6. Gastroretentive Floating Microspheres of Silymarin: Preparation and ...

    African Journals Online (AJOL)

    Erah

    simulated gastric fluid for at least 12 h, and, therefore, could potentially ... systems (GRFDDS) have a bulk density ... The objective of this work was to develop and characterise gastroretentive floating microspheres of silymarin which, following oral administration, would exhibit .... hydrochloric acid to maintain sink conditions.

  7. Structuring of diamond films using microsphere lithography

    Czech Academy of Sciences Publication Activity Database

    Domonkos, Mária; Ižák, Tibor; Štolcová, L.; Proška, J.; Demo, Pavel; Kromka, Alexander

    2014-01-01

    Roč. 54, č. 5 (2014), s. 320-324 ISSN 1210-2709 R&D Projects: GA ČR(CZ) GBP108/12/G108 Institutional support: RVO:68378271 Keywords : nanostructuring * diamond thin films * polystyrene microspheres * reactive ion etching * scanning electron microscopy Subject RIV: BM - Solid Matter Physics ; Magnetism

  8. Method and apparatus for producing microspherical particles

    International Nuclear Information System (INIS)

    Egli, W.; Bailey, W.H.; Leary, D.F.; Lansley, R.J.

    1979-01-01

    This invention relates generally to a method and apparatus for producing microspherical particles and more particularly to a method and apparatus which are particularly useful in connection with the sol-gel process for the production of nuclear fuel kernels. (U.K.)

  9. MICROSPHERE SIZE INFLUENCES THE FOREIGN BODY REACTION

    NARCIS (Netherlands)

    Zandstra, J.; Hiemstra, C.; Petersen, A. H.; Zuidema, J.; van Beuge, M. M.; Rodriguez, S.; Lathuile, A. A. R.; Veldhuis, G. J.; Steendam, R.; Bank, R. A.; Popa, E. R.

    2014-01-01

    Biodegradable poly-(DL-lactide-co-glycolide) (PLGA) microspheres (MSP) are attractive candidate vehicles for site-specific or systemic sustained release of therapeutic compounds. This release may be altered by the host's foreign body reaction (FBR), which is dependent on the characteristics of the

  10. Beat-Frequency/Microsphere Medical Ultrasonic Imaging

    Science.gov (United States)

    Yost, William T.; Cantrell, John H.; Pretlow, Robert A., III

    1995-01-01

    Medical ultrasonic imaging system designed to provide quantitative data on various flows of blood in chambers, blood vessels, muscles, and tissues of heart. Sensitive enough to yield readings on flows of blood in heart even when microspheres used as ultrasonic contrast agents injected far from heart and diluted by circulation of blood elsewhere in body.

  11. Prolonged amelioration of experimental postoperative pain by bupivacaine released from microsphere-coated hernia mesh.

    Science.gov (United States)

    Ohri, Rachit; Wang, Jeffery Chi-Fei; Pham, Lan; Blaskovich, Phillip D; Costa, Daniel; Nichols, Gary; Hildebrand, William; Scarborough, Nelson; Herman, Clifford; Strichartz, Gary R

    2014-01-01

    Postoperative pain alters physiological functions and delays discharge. Perioperative local anesthetics are effective analgesics in the immediate 1- to 2-day postoperative period, but acute pain often lasts longer. The goal of this work was to develop a local anesthetic formulation adhering to an intraoperative implanted device that reduces pain for at least 3 days after surgery. Six groups, each with 8 rats, were studied. In a control group (group I), one 1.2-cm-long incision of the skin was followed by blunt dissection to separate the skin away from the underlying tissues and closing with 2 sutures. In 3 of the treatment groups, the same surgical procedure was used, with the subcutaneous space formed by the blunt dissection lined with a 1-cm square patch of hernia mesh coated with poly lactide co-glycolic acid microspheres containing approximately 17 mg of bupivacaine (group II), no drug (placebo; group III), or bupivacaine free-base powder (group IV). Uncoated mesh implants (group V) served as a secondary control. A standard bupivacaine solution (0.4 mL, 0.5%; 2-mg dose) was infiltrated subcutaneously 30 minutes before the surgery and served as a standard control (group VI). Mechanosensitivity of the skin was tested by the local subcutaneous muscle responses to cutaneous tactile stimulation by von Frey hairs with forces of 4 g (for allodynia) and 15 g (for hyperalgesia) preoperatively and for 7 postoperative days. Control rats (group I) showed mechanohypersensitivity, indicative of postoperative allodynia and hyperalgesia, for all 7 postoperative days. Mechanohyperalgesia in rats that received mesh coated with bupivacaine-releasing microspheres (group II) was reduced during this period to 13% of control postoperative values (P < 0.001); mesh coated with bupivacaine base (group IV) reduced it by 50% (P = 0.034). The placebo mesh (group III) and uncoated mesh (group V) caused no significant reduction of mechanohypersensitivity, and bupivacaine solution infiltrated

  12. Preoperative alcoholism and postoperative morbidity

    DEFF Research Database (Denmark)

    Tonnesen, H; Kehlet, H

    1999-01-01

    BACKGROUND: Preoperative risk assessment has become part of daily clinical practice, but preoperative alcohol abuse has not received much attention. METHODS: A Medline search was carried out to identify original papers published from 1967 to 1998. Relevant articles on postoperative morbidity...... in alcohol abusers were used to evaluate the evidence. RESULTS: Prospective and retrospective studies demonstrate a twofold to threefold increase in postoperative morbidity in alcohol abusers, the most frequent complications being infections, bleeding and cardiopulmonary insufficiency. Wound complications...... to postoperative morbidity. CONCLUSION: Alcohol consumption should be included in the preoperative assessment of likely postoperative outcome. Reduction of postoperative morbidity in alcohol abusers may include preoperative alcohol abstinence to improve organ function, or perioperative alcohol administration...

  13. Hydrogen transport and storage in engineered glass microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Rambach, G.D.

    1994-04-20

    New, high-strength, hollow, glass microspheres filled with pressurized hydrogen exhibit storage densities which make them attractive for bulk hydrogen storage and transport. The hoop stress at failure of our engineered glass microspheres is about 150,000 psi, permitting a three-fold increase in pressure limit and storage capacity above commercial microspheres, which fail at wall stresses of 50,000 psi. For this project, microsphere material and structure will be optimized for storage capacity and charge/discharge kinetics to improve their commercial practicality. Microsphere production scale up will be performed, directed towards large-scale commercial use. Our analysis relating glass microspheres for hydrogen transport with infrastructure and economics` indicate that pressurized microspheres can be economically competitive with other forms of bulk rail and truck transport such as hydride beds, cryocarbons and pressurized tube transports. For microspheres made from advanced materials and processes, analysis will also be performed to identify the appropriate applications of the microspheres considering property variables, and different hydrogen infrastructure, end use, production and market scenarios. This report presents some of the recent modelling results for large beds of glass microspheres in hydrogen storage applications. It includes plans for experiments to identify the properties relevant to large-bed hydrogen transport and storage applications, of the best, currently producible, glass microspheres. This work began in March, 1994. Project successes will be manifest in the matching of cur-rent glass microspheres with a useful application in hydrogen bulk transport and storage, and in developing microsphere materials and processes that increase the storage density and reduce the storage energy requirement.

  14. In vitro evaluation of biodegradable microspheres with surface-bound ligands.

    Science.gov (United States)

    Keegan, Mark E; Royce, Sara M; Fahmy, Tarek; Saltzman, W Mark

    2006-02-21

    Protein ligands were conjugated to the surface of biodegradable microspheres. These microsphere-ligand conjugates were then used in two in vitro model systems to evaluate the effect of conjugated ligands on microsphere behavior. Microsphere retention in agarose columns was increased by ligands on the microsphere surface specific for receptors on the agarose matrix. In another experiment, conjugating the lectin Ulex europaeus agglutinin 1 to the microsphere surface increased microsphere adhesion to Caco-2 monolayers compared to control microspheres. This increase in microsphere adhesion was negated by co-administration of l-fucose, indicating that the increase in adhesion is due to specific interaction of the ligand with carbohydrate receptors on the cell surface. These results demonstrate that the ligands conjugated to the microspheres maintain their receptor binding activity and are present on the microsphere surface at a density sufficient to target the microspheres to both monolayers and three-dimensional matrices bearing complementary receptors.

  15. Yttrium-90 Resin Microsphere Radioembolization Using an Antireflux Catheter: An Alternative to Traditional Coil Embolization for Nontarget Protection

    International Nuclear Information System (INIS)

    Morshedi, Maud M.; Bauman, Michael; Rose, Steven C.; Kikolski, Steven G.

    2015-01-01

    PurposeSerious complications can result from nontarget embolization during yttrium-90 (Y-90) transarterial radioembolization. Hepatoenteric artery coil embolization has been traditionally performed to prevent nontarget radioembolization. The U.S. Food and Drug Administration–approved Surefire Infusion System (SIS) catheter, designed to prevent reflux, is an alternative to coils. The hypothesis that quantifiable SIS procedural parameters are comparable to coil embolization was tested.MethodsFourteen patients aged 36–79 years with colorectal, neuroendocrine, hepatocellular, and other predominantly bilobar hepatic tumors who underwent resin microsphere Y-90 radioembolization using only the SIS catheter (n = 7) versus only detachable coils (n = 7) for nontarget protection were reviewed retrospectively. Procedure time, fluoroscopy time, contrast dose, radiation dose, and cost were evaluated.ResultsMultivariate analysis identified significant cohort differences in the procedural parameters evaluated (F(10, 3) = 10.39, p = 0.04). Between-group comparisons of the pretreatment planning procedure in the SIS catheter group compared to the coil embolization group demonstrated a significant reduction in procedure time (102.6 vs. 192.1 min, respectively, p = 0.0004), fluoroscopy time (14.3 vs. 49.7 min, respectively, p = 0.0016), and contrast material dose (mean dose of 174.3 vs. 265.0 mL, respectively, p = 0.0098). Procedural parameters were not significantly different between the two groups during subsequent dose delivery procedures. Overall cost of combined first-time radioembolization procedures was significantly less in the SIS group ($4252) compared to retrievable coil embolization ($11,123; p = 0.001).ConclusionThe SIS catheter results in a reduction in procedure time, fluoroscopy time, and contrast material dose and may be an attractive cost-effective alternative to detachable coil embolization for prevention of nontarget radioembolization

  16. Yttrium-90 Resin Microsphere Radioembolization Using an Antireflux Catheter: An Alternative to Traditional Coil Embolization for Nontarget Protection

    Energy Technology Data Exchange (ETDEWEB)

    Morshedi, Maud M., E-mail: maud.morshedi@my.rfums.org; Bauman, Michael, E-mail: mbauman@ucsd.edu; Rose, Steven C., E-mail: scrose@ucsd.edu; Kikolski, Steven G., E-mail: skikolski@gmail.com [University of California San Diego Health Sciences, Radiology Department, University of California San Diego Medical Center (United States)

    2015-04-15

    PurposeSerious complications can result from nontarget embolization during yttrium-90 (Y-90) transarterial radioembolization. Hepatoenteric artery coil embolization has been traditionally performed to prevent nontarget radioembolization. The U.S. Food and Drug Administration–approved Surefire Infusion System (SIS) catheter, designed to prevent reflux, is an alternative to coils. The hypothesis that quantifiable SIS procedural parameters are comparable to coil embolization was tested.MethodsFourteen patients aged 36–79 years with colorectal, neuroendocrine, hepatocellular, and other predominantly bilobar hepatic tumors who underwent resin microsphere Y-90 radioembolization using only the SIS catheter (n = 7) versus only detachable coils (n = 7) for nontarget protection were reviewed retrospectively. Procedure time, fluoroscopy time, contrast dose, radiation dose, and cost were evaluated.ResultsMultivariate analysis identified significant cohort differences in the procedural parameters evaluated (F(10, 3) = 10.39, p = 0.04). Between-group comparisons of the pretreatment planning procedure in the SIS catheter group compared to the coil embolization group demonstrated a significant reduction in procedure time (102.6 vs. 192.1 min, respectively, p = 0.0004), fluoroscopy time (14.3 vs. 49.7 min, respectively, p = 0.0016), and contrast material dose (mean dose of 174.3 vs. 265.0 mL, respectively, p = 0.0098). Procedural parameters were not significantly different between the two groups during subsequent dose delivery procedures. Overall cost of combined first-time radioembolization procedures was significantly less in the SIS group ($4252) compared to retrievable coil embolization ($11,123; p = 0.001).ConclusionThe SIS catheter results in a reduction in procedure time, fluoroscopy time, and contrast material dose and may be an attractive cost-effective alternative to detachable coil embolization for prevention of nontarget radioembolization.

  17. Optically Levitated Microspheres as a Probe for New Interactions

    Science.gov (United States)

    Rider, Alexander; Moore, David; Blakemore, Charles; Lu, Marie; Gratta, Giorgio

    2016-03-01

    We are developing novel techniques to probe new interactions at micron distances using optically levitated dielectric microspheres. Levitated microspheres are an ideal probe for short-range interactions because they are suspended using the radiation pressure at the focus of a laser beam, which means that the microspheres can be precisely manipulated and isolated from the surrounding environment at high vacuum. We have performed a search for unknown charged particles bound within the bulk of the microspheres. Currently, we are searching for the presence of a Chameleon field postulated to explain the presence of dark energy in the universe. In the future we plan to use optically levitated microspheres to search for micron length-scale gravity like interactions that could couple between a microsphere and another mass. We will present resent results from these experiments and plans for future searches for new interactions.

  18. Hydrogen transport and storage in engineered glass microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Rambach, G.D.

    1995-02-28

    New, high strength glass microspheres filled with pressurized hydrogen exhibit densities which make them attractive for bulk hydrogen storage and transport. The membrane tensile stress at failure for engineered glass microspheres is about 150,000 psi, permitting a three-fold increase in pressure limit and storage capacity above commercial microspheres, which have been studied a decade ago and have been shown to fail at membrane stresses of 50,000 psi. This analysis relating glass microspheres for hydrogen transport with infrastructure and economics, indicate that pressurized microspheres can be economically competitive with other forms of bulk rail and truck transport such as pressurized tube transports and liquid hydrogen trailers. This paper will describe the matching of current glass microspheres with the useful application in commercial hydrogen bulk transport and storage.

  19. Beat frequency ultrasonic microsphere contrast agent detection system

    Science.gov (United States)

    Pretlow, III, Robert A. (Inventor); Yost, William T. (Inventor); Cantrell, Jr., John H. (Inventor)

    1997-01-01

    A system for and method of detecting and measuring concentrations of an ultrasonically-reflective microsphere contrast agent involving detecting non-linear sum and difference beat frequencies produced by the microspheres when two impinging signals with non-identical frequencies are combined by mixing. These beat frequencies can be used for a variety of applications such as detecting the presence of and measuring the flow rates of biological fluids and industrial liquids, including determining the concentration level of microspheres in the myocardium.

  20. Microsphere formation in droplets using antisolvent vapour precipitation technique

    OpenAIRE

    Chew, Sean Jun Liang

    2017-01-01

    In previous studies, the antisolvent vapour precipitation method has been proven to produce uniformly sized lactose microspheres (1.0 µm) from a single droplet (1.2 mm diameter) at atmospheric pressure. These types of particles have potential applications in the pharmaceutical industry, especially due to their high dissolution rate. This project looked into the possibility of using antisolvent vapour precipitation to produce microspheres from finely atomised droplets. Microspheres in the sub-...

  1. Preparation of polystyrene microsphere with emulsion microencapsulation method

    International Nuclear Information System (INIS)

    Li Bo Zhang Lin; Zhang Zhganwen; You Dan; Wei Yun; Wang Chaoyang; Lin Bo; Shi Tao; Chu Qiaomei

    2003-01-01

    The preparation of hollow polystyrene microspheres that are used as inner shell of multi-shell plastic microspheres in the ICF experiments is focused on. The effects of surfactants, water-soluble polymer and electrolyte on the properties of resultant microspheres are studied. Based on these experiments, a fabricating procedure was established with which hollow microspheres were prepared with diameter about 150-3000 μm, wall thickness 0.8-15 μm and toughness Ra less than 4 nm. (authors)

  2. Intestinal absorption of PLAGA microspheres in the rat.

    Science.gov (United States)

    Damgé, C; Aprahamian, M; Marchais, H; Benoit, J P; Pinget, M

    1996-12-01

    Rhodamine B-labelled poly (DL-lactide-co-glycolide) (PLAGA) microspheres of 2 different sizes, 1-5 microns and 5-10 microns, were administered as a single dose (1.44 x 10(9) and 1.83 x 10(8) particles, respectively) into the ileal lumen of adult rats. The content of rhodamine in the mesenteric vein and ileal lumen was analysed periodically from 10 min to 48 h as well as the distribution of microspheres in the intestinal mucosa and various other tissues. The concentration of rhodamine decreased progressively in the intestinal lumen and was negligible after 24 h. The number of microspheres in the mesenteric vein increased rapidly and reached a maximum after 4 h whatever the size of the particles. It then decreased progressively, but more rapidly with microspheres > 5 microns than with microspheres PLAGA microspheres mainly crossed the intestinal mucosa at the site of Peyer's patches where microspheres of 5 microns were retained in the ileal lumen. A few small microspheres were occasionally observed in the epithelial cells. Only the smallest particles were recovered in the liver, lymph nodes and spleen while basement membranes were always labelled. It is concluded that PLAGA microspheres could be useful for the oral delivery of antigens if their size is between 1 and 5 microns.

  3. Preparation of porous zirconia microspheres by internal gelation method

    International Nuclear Information System (INIS)

    Pathak, Sachin S.; Pius, I.C.; Bhanushali, R.D.; Rao, T.V. Vittal; Mukerjee, S.K.

    2008-01-01

    A modified internal gelation process for the preparation of porous zirconia microspheres has been developed. The conventional method has been modified by adding a surfactant in the feed broth. The effects of variation of surfactant concentration, washing techniques and temperature of calcination on the pore volume and the surface area of the microspheres have been studied. The conditions were optimized to obtain porous stable microspheres suitable for various applications. The microspheres were characterized by surface area analysis, pore volume analysis, thermogravimetric analysis and X-ray diffraction. The ion exchange behavior was studied using pH titration

  4. Photoluminescence and lasing in whispering gallery mode glass microspherical resonators

    Energy Technology Data Exchange (ETDEWEB)

    Ristić, D. [Ruđer Bošković Institute, Division of Materials Physics, Laboratory for Molecular Physics, Bijenička c. 54, Zagreb (Croatia); Center of Excellence for Advanced Materials and Sensing Devices, Research unit New Functional Materials, Bijenička c. 54, Zagreb (Croatia); Berneschi, S.; Camerini, M. [IFAC-CNR Istituto di Fisica Applicata, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy); Farnesi, D.; Pelli, S. [IFAC-CNR Istituto di Fisica Applicata, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy); Centro Studi e Ricerche ' E. Fermi' , Piazza del Viminale 2, 00184 Roma (Italy); Trono, C. [IFAC-CNR Istituto di Fisica Applicata, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy); Chiappini, A.; Chiasera, A.; Ferrari, M. [CSMFO Group, Istituto di Fotonica e Nanotecnologie, IFN-CNR, Via alla Cascata 56/C, 38050 Povo-Trento (Italy); Lukowiak, A. [Institute of Low Temperature and Structure Research, PAS, ul. Okolna 2, Wroclaw 50-950 (Poland); Dumeige, Y.; Féron, P. [Laboratoire d' Optronique, (CNRS-UMR 6082-Foton), ENSSAT, 6 rue de Kérampont, 22300 Lannion (France); Righini, G.C. [IFAC-CNR Istituto di Fisica Applicata, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy); Centro Studi e Ricerche ' E. Fermi' , Piazza del Viminale 2, 00184 Roma (Italy); Soria, S., E-mail: s.soria@ifac.cnr.it [IFAC-CNR Istituto di Fisica Applicata, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy); Conti, G. Nunzi [IFAC-CNR Istituto di Fisica Applicata, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy); Centro Studi e Ricerche ' E. Fermi' , Piazza del Viminale 2, 00184 Roma (Italy)

    2016-02-15

    We report experimental results regarding the development of Er{sup 3+}-doped glass microspherical cavities for the fabrication of compact sources at 1.55 μm. We investigate several different approaches in order to fabricate the microspheres including direct melting of Er{sup 3+}-doped glass powders, synthesis of Er{sup 3+}-doped monolithic microspheres by drawing Er{sup 3+}-doped glass, and coating of silica microspheres with an Er{sup 3+}-doped sol–gel layer. Details of the different fabrication processes are presented together with the photoluminescence characterization in free space configuration of the microspheres and of the glass precursor. We have analyzed the photoluminescence spectra of the whispering gallery modes of the microspheres excited using evanescent coupling and we demonstrate tunable laser action in a wide range of wavelengths around 1.55 μm. As much as 90 μW of laser output power was measured in Er{sup 3+}-doped glass microspheres. - Highlights: • Different approaches in microsphere fabrication and various types of post-processing. • Trimming of photorefractive glass microsphere lasers with UV light. • Peak power record of 90 μW by pumping at 1480 nm.

  5. Microsphere based improved sunscreen formulation of ethylhexyl methoxycinnamate.

    Science.gov (United States)

    Gogna, Deepak; Jain, Sunil K; Yadav, Awesh K; Agrawal, G P

    2007-04-01

    Polymethylmethacrylate (PMMA) microspheres of ethylhexyl methoxycinnamate (EHM) were prepared by emulsion solvent evaporation method to improve its photostability and effectiveness as sunscreening agent. Process parameters like stirring speed and aqueous polyvinyl alcohol (PVA) concentration were analyzed in order to optimize the formulations. Shape and surface morphology of the microspheres were examined using scanning electron microscopy. Particle size of the microspheres was determined using laser diffraction particle size analyzer. The PMMA microspheres of EHM were incorporated in water-removable cream base. The in vitro drug release of EHM in pH 7.4 was performed using dialysis membrane. Thin layer chromatography was performed to determine photostability of EHM inside the microspheres. The formulations were evaluated for sun protection factor (SPF) and minimum erythema dose (MED) in albino rats. Cream base formulation containing microspheres prepared using EHM:PMMA in ratio of 1:3 (C(3)) showed slowest drug (EHM) release and those prepared with EHM: PMMA in ratio of 1:1 showed fastest release. The cream base formulations containing EHM loaded microspheres had shown better SPF (more than 16.0) as compared to formulation C(d) that contained 3% free EHM as sunscreen agent and showed SPF 4.66. These studies revealed that the incorporation of EHM loaded PMMA microspheres into cream base had greatly increased the efficacy of sunscreen formulation approximately four times. Further, photostability was also shown to be improved in PMMA microspheres.

  6. Low pressure gas filling of laser fusion microspheres

    International Nuclear Information System (INIS)

    Koo, J.C.; Dressler, J.L.; Hendricks, C.D.

    1979-01-01

    In our laser fusion microsphere production, large, thin gel-microspheres are formed before the chemicals are fused into glass. In this transient stage,, the gel-microspheres are found to be highly permeable to argon and many other inert gases. When the gel transforms to glass, the argon gas, for example, is trapped within to form argon filled, fusion target quality, glass microspheres. On the average, the partial pressure of the argon fills attained in this process is around 2 x 10 4 Pa at room temperature

  7. Histological Comparison of Kidney Tissue Following Radioembolization with Yttrium-90 Resin Microspheres and Embolization with Bland Microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Suresh de, E-mail: suresh.desilva@unsw.edu.au [Southern Radiology Group, Radiology Department Sutherland Hospital (Australia); Mackie, Simon [Western General Hospital, Department of Urology (United Kingdom); Aslan, Peter [St George Hospital, Department of Urology (Australia); Cade, David [Sirtex Technology Pty Ltd (Australia); Delprado, Warick [Douglass Hanly Moir Pathology (Australia)

    2016-12-15

    BackgroundIntra-arterial brachytherapy with yttrium-90 ({sup 90}Y) resin microspheres (radioembolization) is a procedure to selectively deliver high-dose radiation to tumors. The purpose of this research was to compare the radioembolic effect of {sup 90}Y-radioembolization versus the embolic effect of bland microspheres in the porcine kidney model.MethodsIn each of six pigs, ~25–33 % of the kidney volume was embolized with {sup 90}Y resin microspheres and an equivalent number of bland microspheres in the contralateral kidney. Kidney volume was estimated visually from contrast-enhanced fluoroscopy imaging. Morphologic and histologic analysis was performed 8–9 weeks after the procedure to assess the locations of the microspheres and extent of tissue necrosis from {sup 90}Y-radioembolization and bland embolization. A semi-quantified evaluation of the non-acute peri-particle and perivascular tissue reaction was conducted. All guidelines for the care and use of animals were followed.ResultsKidneys embolized with {sup 90}Y-radioembolization decreased in mass by 30–70 % versus the contralateral kidney embolized with bland microspheres. These kidneys showed significant necrosis/fibrosis, avascularization, and glomerular atrophy in the immediate vicinity of the {sup 90}Y resin microspheres. By contrast, glomerular changes were not observed, even with clusters of bland microspheres in afferent arterioles. Evidence of a foreign body reaction was recorded in some kidneys with bland microspheres, and subcapsular scarring/infarction only with the highest load (4.96 × 10{sup 6}) of bland microspheres.ConclusionThis study showed that radioembolization with {sup 90}Y resin microspheres produces localized necrosis/fibrosis and loss of kidney mass in a porcine kidney model. This result supports the study of {sup 90}Y resin microspheres for the localized treatment of kidney tumors.

  8. A novel route for synthesis and growth formation of metal oxides microspheres: Insights from V_2O_3 microspheres

    International Nuclear Information System (INIS)

    Zhang, Yifu; Huang, Chi; Meng, Changgong; Hu, Tao

    2016-01-01

    Highly polydisperse V_2O_3 solid microspheres with large specific surface area were successfully synthesized via a facile hydrothermal decomposition of VOC_2O_4 solution. The morphology and composition were characterized by scanning electron microscopy (SEM), Energy dispersive spectrometer (EDS), X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD). V_2O_3 microspheres display an obvious Mott phase transition at −128.5 °C (cooling curve) and −114.5 °C (heating curve). Some parameters including the reaction temperature, concentration of VOC_2O_4, reaction time, surfactant, H_2C_2O_4 and precursor were briefly discussed to reveal the formation of V_2O_3 microspheres. It was found that the precursor is crucial for the fabrication of microsphere. A self-assembly growth mechanism was suggested to explain the growth process of microspheres and the autogenic CO and CO_2 gas served as the soft templates. Furthermore, this route was developed to synthesize different metal oxides microspheres, and it was found that AlO(OH), Fe_3O_4, Fe_2O_3, Co_3O_4, Cr_2O_3, MoO_2 and WO_3 microspheres were obtained. All the results showed this process was successfully explored as a methodology to synthesize different metal oxides microspheres using the gas as the templates by this facile hydrothermal route. - Highlights: • Highly uniform V_2O_3 solid microspheres were synthesized. • V_2O_3 microspheres display an obvious Mott phase transition. • The autogenic CO and CO_2 gas served as the soft templates for designed synthesis. • AlO(OH), Fe_3O_4, Fe_2O_3, Co_3O_4, Cr_2O_3, MoO_2 and WO_3 microspheres were obtained. • A methodology to synthesize different metal oxides microspheres was developed.

  9. Histological Comparison of Kidney Tissue Following Radioembolization with Yttrium-90 Resin Microspheres and Embolization with Bland Microspheres

    International Nuclear Information System (INIS)

    Silva, Suresh de; Mackie, Simon; Aslan, Peter; Cade, David; Delprado, Warick

    2016-01-01

    BackgroundIntra-arterial brachytherapy with yttrium-90 ("9"0Y) resin microspheres (radioembolization) is a procedure to selectively deliver high-dose radiation to tumors. The purpose of this research was to compare the radioembolic effect of "9"0Y-radioembolization versus the embolic effect of bland microspheres in the porcine kidney model.MethodsIn each of six pigs, ~25–33 % of the kidney volume was embolized with "9"0Y resin microspheres and an equivalent number of bland microspheres in the contralateral kidney. Kidney volume was estimated visually from contrast-enhanced fluoroscopy imaging. Morphologic and histologic analysis was performed 8–9 weeks after the procedure to assess the locations of the microspheres and extent of tissue necrosis from "9"0Y-radioembolization and bland embolization. A semi-quantified evaluation of the non-acute peri-particle and perivascular tissue reaction was conducted. All guidelines for the care and use of animals were followed.ResultsKidneys embolized with "9"0Y-radioembolization decreased in mass by 30–70 % versus the contralateral kidney embolized with bland microspheres. These kidneys showed significant necrosis/fibrosis, avascularization, and glomerular atrophy in the immediate vicinity of the "9"0Y resin microspheres. By contrast, glomerular changes were not observed, even with clusters of bland microspheres in afferent arterioles. Evidence of a foreign body reaction was recorded in some kidneys with bland microspheres, and subcapsular scarring/infarction only with the highest load (4.96 × 10"6) of bland microspheres.ConclusionThis study showed that radioembolization with "9"0Y resin microspheres produces localized necrosis/fibrosis and loss of kidney mass in a porcine kidney model. This result supports the study of "9"0Y resin microspheres for the localized treatment of kidney tumors.

  10. Neutron transmission measurements on hydrogen filled microspheres

    International Nuclear Information System (INIS)

    Dyrnjaja, Eva; Hummel, Stefan; Keding, Marcus; Smolle, Marie-Theres; Gerger, Joachim; Zawisky, Michael

    2014-01-01

    Hollow microspheres are promising candidates for future hydrogen storage technologies. Although the physical process for hydrogen diffusion through glass is well understood, measurements of static quantities (e.q. hydrogen pressure inside the spheres) as well as dynamic properties (e.g. diffusion rate of hydrogen through glass) are still difficult to handle due to the small size of the spheres (d≈15μm). For diffusion rate measurements, the long-term stability of the experiment is also mandatory due to the relatively slow diffusion rate. In this work, we present an accurate and long-term stable measurement technique for static and dynamic properties, using neutron radiography. Furthermore, possible applications for hydrogen filled microspheres within the scope of radiation issues are discussed

  11. Optical Microspherical Resonators for Biomedical Sensing

    Directory of Open Access Journals (Sweden)

    Giancarlo C. Righini

    2011-01-01

    Full Text Available Optical resonators play an ubiquitous role in modern optics. A particular class of optical resonators is constituted by spherical dielectric structures, where optical rays are total internal reflected. Due to minimal reflection losses and to potentially very low material absorption, these guided modes, known as whispering gallery modes, can confer the resonator an exceptionally high quality factor Q, leading to high energy density, narrow resonant-wavelength lines and a lengthy cavity ringdown. These attractive characteristics make these miniaturized optical resonators especially suited as laser cavities and resonant filters, but also as very sensitive sensors. First, a brief analysis is presented of the characteristics of microspherical resonators, of their fabrication methods, and of the light coupling techniques. Then, we attempt to overview some of the recent advances in the development of microspherical biosensors, underlining a number of important applications in the biomedical field.

  12. Aptamer Based Microsphere Biosensor for Thrombin Detection

    Directory of Open Access Journals (Sweden)

    Xudong Fan

    2006-08-01

    Full Text Available We have developed an optical microsphere resonator biosensor using aptamer asreceptor for the measurement of the important biomolecule thrombin. The sphere surface ismodified with anti-thrombin aptamer, which has excellent binding affinity and selectivityfor thrombin. Binding of the thrombin at the sphere surface is monitored by the spectralposition of the microsphere’s whispering gallery mode resonances. A detection limit on theorder of 1 NIH Unit/mL is demonstrated. Control experiments with non-aptameroligonucleotide and BSA are also carried out to confirm the specific binding betweenaptamer and thrombin. We expect that this demonstration will lead to the development ofhighly sensitive biomarker sensors based on aptamer with lower cost and higher throughputthan current technology.

  13. Sputter coating of microspherical substrates by levitation

    Science.gov (United States)

    Lowe, A.T.; Hosford, C.D.

    Microspheres are substantially uniformly coated with metals or nonmetals by simltaneously levitating them and sputter coating them at total chamber pressures less than 1 torr. A collimated hole structure comprising a parallel array of upwardly projecting individual gas outlets is machined out to form a dimple. Glass microballoons,, which are particularly useful in laser fusion applications, can be substantially uniformly coated using the coating method and apparatus.

  14. Interventions for preoperative smoking cessation

    DEFF Research Database (Denmark)

    Thomsen, Thordis; Villebro, Nete; Møller, Ann Merete

    2014-01-01

    BACKGROUND: Smokers have a substantially increased risk of postoperative complications. Preoperative smoking intervention may be effective in decreasing this incidence, and surgery may constitute a unique opportunity for smoking cessation interventions. OBJECTIVES: The objectives of this review...... are to assess the effect of preoperative smoking intervention on smoking cessation at the time of surgery and 12 months postoperatively, and on the incidence of postoperative complications. SEARCH METHODS: We searched the Cochrane Tobacco Addiction Group Specialized Register in January 2014. SELECTION CRITERIA......: Randomized controlled trials that recruited people who smoked prior to surgery, offered a smoking cessation intervention, and measured preoperative and long-term abstinence from smoking or the incidence of postoperative complications or both outcomes. DATA COLLECTION AND ANALYSIS: The review authors...

  15. Glass microspheres covering film: first field evaluations

    International Nuclear Information System (INIS)

    Magnani, G.; Filippi, F.

    2006-01-01

    A trial was carried out to evaluate, in the North-Centre of Italy, the behaviour in field of a new plastic covering film, prepared with the inclusion of empty glass microspheres (Solex). The trial was conducted on tomato (Lycopersicon esculentum L.) and eggplant (Solanum melongena L.). The new film was compared to a covering film with the same optical (diffuse light) and constitutional (co-extruded three layers EVA-WPE) characteristics. Since the first results, the innovative film showed a better behaviour than the control one. It presented light and thermal conditions (lower temperature during the day and slightly higher temperature in the night, compared to the control film) that allowed a better growth and yield than the control film. The growth analysis of tomato showed that plants grown under glass microsphere film had an higher growth rate (dry weight/days) and thickness of leaves compared to the control one. The yield of tomato and eggplant presented an increase in plants cultivated under the innovative film, especially for number and weight of fruits. The commercial quality did not show any differences between the films, except for the flesh hardness of tomato: this could be explained with the fact that the glass microspheres film provides environmental conditions avoiding plant stress during some stages of its cycle [it

  16. STRUCTURING OF DIAMOND FILMS USING MICROSPHERE LITHOGRAPHY

    Directory of Open Access Journals (Sweden)

    Mária Domonkos

    2014-10-01

    Full Text Available In this study, the structuring of micro- and nanocrystalline diamond thin films is demonstrated. The structuring of the diamond films is performed using the technique of microsphere lithography followed by reactive ion etching. Specifically, this paper presents a four-step fabrication process: diamond deposition (microwave plasma assisted chemical vapor deposition, mask preparation (by the standard Langmuir-Blodgett method, mask modification and diamond etching. A self-assembled monolayer of monodisperse polystyrene (PS microspheres with close-packed ordering is used as the primary template. Then the PS microspheres and the diamond films are processed in capacitively coupled radiofrequency plasma  using different plasma chemistries. This fabrication method illustrates the preparation of large arrays of periodic and homogeneous hillock-like structures. The surface morphology of processed diamond films is characterized by scanning electron microscopy and atomic force microscope. The potential applications of such diamond structures in various fields of nanotechnology are also briefly discussed.

  17. Yttrium-90 microsphere induced gastrointestinal tract ulceration

    Directory of Open Access Journals (Sweden)

    Rikabi Ali A

    2008-09-01

    Full Text Available Abstract Background Radiomicrosphere therapy (RT utilizing yttrium-90 (90Y microspheres has been shown to be an effective regional treatment for primary and secondary hepatic malignancies. We sought to determine a large academic institution's experience regarding the extent and frequency of gastrointestinal complications. Methods Between 2004 and 2007, 27 patients underwent RT for primary or secondary hepatic malignancies. Charts were subsequently reviewed to determine the incidence and severity of GI ulceration. Results Three patients presented with gastrointestinal bleeding and underwent upper endoscopy. Review of the pretreatment angiograms showed normal vascular anatomy in one patient, sclerosed hepatic vasculature in a patient who had undergone prior chemoembolization in a second, and an aberrant left hepatic artery in a third. None had undergone prophylactic gastroduodenal artery embolization. Endoscopic findings included erythema, mucosal erosions, and large gastric ulcers. Microspheres were visible on endoscopic biopsy. In two patients, gastric ulcers were persistent at the time of repeat endoscopy 1–4 months later despite proton pump inhibitor therapy. One elderly patient who refused surgical intervention died from recurrent hemorrhage. Conclusion Gastrointestinal ulceration is a known yet rarely reported complication of 90Y microsphere embolization with potentially life-threatening consequences. Once diagnosed, refractory ulcers should be considered for aggressive surgical management.

  18. Adsorption behavior of protein onto siloxane microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Liu Bailing [Chengdu Institute of Organic Chemistry, Graduate School of CAS, Chinese Academy of Sciences, Chengdu 610041 (China)]. E-mail: Blliuchem@hotmail.com; Cao Shunsheng [Chengdu Institute of Organic Chemistry, Graduate School of CAS, Chinese Academy of Sciences, Chengdu 610041 (China); Deng Xiaobo [Chengdu Institute of Organic Chemistry, Graduate School of CAS, Chinese Academy of Sciences, Chengdu 610041 (China); Li Songjun [Chengdu Institute of Organic Chemistry, Graduate School of CAS, Chinese Academy of Sciences, Chengdu 610041 (China); Luo Rong [Chengdu Institute of Organic Chemistry, Graduate School of CAS, Chinese Academy of Sciences, Chengdu 610041 (China)

    2006-09-15

    The siloxane microspheres with core-shell structure (PMMA/PMPS) (MMA, methyl methacrylate; MPS, 3-methacryloxypropyl-trimethoxysilane) have been prepared by dispersion polymerization as described in our previous work. In this paper, the developed poly(MMA-MPS) microspheres, as a carrier, are used to investigate the adsorption behavior of bovine serum albumin (BSA) on them. The Langmuir and Freundlich models have been applied to describe the adsorption behavior. The experimental results indicated that the presence of PMPS evidently increases the adsorption rate and the amount of protein, and it also influences the interaction of BSA molecules. The adsorption of BSA on the poly(MMA-MPS) microspheres seems to be sensitive to pH and ionic strength. The fittings curves from Langmuir and Freundlich models showed that the adsorption was actually more complicated than ideal situation because one or more interactions were involved in the process. For understanding the electronic contribution, the Zeta potential was used to measure the reactive system before and after protein adsorption.

  19. Adsorption behavior of protein onto siloxane microspheres

    International Nuclear Information System (INIS)

    Liu Bailing; Cao Shunsheng; Deng Xiaobo; Li Songjun; Luo Rong

    2006-01-01

    The siloxane microspheres with core-shell structure (PMMA/PMPS) (MMA, methyl methacrylate; MPS, 3-methacryloxypropyl-trimethoxysilane) have been prepared by dispersion polymerization as described in our previous work. In this paper, the developed poly(MMA-MPS) microspheres, as a carrier, are used to investigate the adsorption behavior of bovine serum albumin (BSA) on them. The Langmuir and Freundlich models have been applied to describe the adsorption behavior. The experimental results indicated that the presence of PMPS evidently increases the adsorption rate and the amount of protein, and it also influences the interaction of BSA molecules. The adsorption of BSA on the poly(MMA-MPS) microspheres seems to be sensitive to pH and ionic strength. The fittings curves from Langmuir and Freundlich models showed that the adsorption was actually more complicated than ideal situation because one or more interactions were involved in the process. For understanding the electronic contribution, the Zeta potential was used to measure the reactive system before and after protein adsorption

  20. Preoperative staging of rectal cancer.

    Science.gov (United States)

    Smith, Neil; Brown, Gina

    2008-01-01

    Detailed preoperative staging using high resolution magnetic resonance imaging (MRI) enables the selection of patients that require preoperative therapy for tumour regression. This information can be used to instigate neoadjuvant therapy in those patients with poor prognostic features prior to disturbing the tumour bed and potentially disseminating disease. The design of trials incorporating MR assessment of prognostic factors prior to therapy has been found to be of value in assessing treatment modalities and outcomes that are targeted to these preoperative prognostic subgroups and in providing a quantifiable assessment of the efficacy of particular chemoradiation treatment protocols by comparing pre-treatment MR staging with post therapy histology assessment. At present, we are focused on achieving clear surgical margins of excision (CRM) to avoid local recurrence. We recommend that all patients with rectal cancer should undergo pre-operative MRI staging. Of these, about half will have good prognosis features (T1-T3b, N0, EMVI negative, CRM clear) and may safely undergo primary total mesorectal excision. Of the remainder, those with threatened or involved margins will certainly benefit from pre-operative chemoradiotherapy with the aim of downstaging to permit safe surgical excision. In the future, our ability to recognise features predicting distant failure, such as extramural vascular invasion (EMVI) may be used to stratify patients for neo-adjuvant systemic chemotherapy in an effort to prevent distant relapse. The optimal pre-operative treatment regimes for these patients (radiotherapy alone, systemic chemotherapy alone or combination chemo-radiotherapy) is the subject of current and future trials.

  1. Measurement of blood flow through surgical anastomosis using the radioactive microsphere technique

    Energy Technology Data Exchange (ETDEWEB)

    Hummel, S.J.; Delgado, G.; Butterfield, A.; Dritschilo, A.; Harbert, J.

    1985-10-01

    Two different radioactive microspheres ( U Ce and UWSc) were used to measure blood flow to an area of the large intestine in dogs before and after a surgical resection was performed with surgical staples. The healing of an anastomosis is theoretically related to the blood flow to the anastomotic site. Blood flow studies were conducted in three dogs using this technique. The average blood flow preoperatively was 0.558 mL/minute per gram and 1.04 mL/minute per gram postoperatively. These results indicate a statistically significant increase in blood flow at the anastomotic site six days after anastomosis when compared with the blood flow to the same area before any surgical procedures.

  2. Measurement of blood flow through surgical anastomosis using the radioactive microsphere technique

    International Nuclear Information System (INIS)

    Hummel, S.J.; Delgado, G.; Butterfield, A.; Dritschilo, A.; Harbert, J.

    1985-01-01

    Two different radioactive microspheres ( 141 Ce and 46 Sc) were used to measure blood flow to an area of the large intestine in dogs before and after a surgical resection was performed with surgical staples. The healing of an anastomosis is theoretically related to the blood flow to the anastomotic site. Blood flow studies were conducted in three dogs using this technique. The average blood flow preoperatively was 0.558 mL/minute per gram and 1.04 mL/minute per gram postoperatively. These results indicate a statistically significant increase in blood flow at the anastomotic site six days after anastomosis when compared with the blood flow to the same area before any surgical procedures

  3. Preoperative fasting: a clinical audit.

    Science.gov (United States)

    Roberts, Stuart

    2013-01-01

    This clinical audit examines the adherence to guidelines suggested by the Royal College of Nursing (2005); the results uphold previous studies of a preoperative starving period for patients undergoing elective surgical procedures. Patients excessively starved of food or fluids report problems relating to their health. These include hunger, distress and complaints of nausea.

  4. Controlling silk fibroin microspheres via molecular weight distribution

    International Nuclear Information System (INIS)

    Zeng, Dong-Mei; Pan, Jue-Jing; Wang, Qun; Liu, Xin-Fang; Wang, Hui; Zhang, Ke-Qin

    2015-01-01

    Silk fibroin (SF) microspheres were produced by salting out SF solution via the addition of potassium phosphate buffer solution (K 2 HPO 4 –KH 2 PO 4 ). The morphology, size and polydispersity of SF microspheres were adjusted by changing the molecular weight (MW) distribution and concentration of SF, as well as the ionic strength and pH of the buffer solution. Changing the conditions under which the SF fiber dissolved in the Lithium Boride (LiBr) solution resulted in altering the MW distribution of SF solution. Under optimal salting-out conditions (ionic strength > 0.7 M and pH > 7) and using a smaller and narrower SF MW distribution, SF microspheres with smoother shapes and more uniform sizes were produced. Meanwhile, the size and polydispersity of the microspheres increased when the SF concentration was increased from 0.25 mg/mL to 20 mg/mL. The improved SF microspheres, obtained by altering the distribution of molecular weight, have potential in drug and gene delivery applications. - Highlights: • MW distribution was changed by applying different dissolving methods of SF fiber. • Smaller and narrower MW distribution improves the quality of SF microspheres. • Size and polydispersity of microspheres increase as SF concentration increases. • Improved SF microspheres have potential in drug and gene delivery applications

  5. Toward quantum-limited position measurements using optically levitated microspheres

    International Nuclear Information System (INIS)

    Libbrecht, Kenneth G.; Black, Eric D.

    2004-01-01

    We propose the use of optically levitated microspheres as test masses in experiments aimed at reaching and potentially exceeding the standard quantum limit for position measurements. Optically levitated microspheres have low mass and are essentially free of suspension thermal noise, making them well suited for experimentally testing our understanding of quantum-limited measurements

  6. Toward quantum-limited position measurements using optically levitated microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Libbrecht, Kenneth G.; Black, Eric D

    2004-01-26

    We propose the use of optically levitated microspheres as test masses in experiments aimed at reaching and potentially exceeding the standard quantum limit for position measurements. Optically levitated microspheres have low mass and are essentially free of suspension thermal noise, making them well suited for experimentally testing our understanding of quantum-limited measurements.

  7. Development and evaluation of floating microspheres of curcumin in ...

    African Journals Online (AJOL)

    Purpose: To prepare and evaluate floating microspheres of curcumin for prolonged gastric residence and to study their effect on alloxan-induced diabetic rats. Methods: Floating microsphere were prepared by emulsion-solvent diffusion method, using hydroxylpropyl methylcellulose, chitosan and Eudragit S 100 polymer in ...

  8. Development and Evaluation of Floating Microspheres of Curcumin ...

    African Journals Online (AJOL)

    Purpose: To prepare and evaluate floating microspheres of curcumin for prolonged gastric residence time and increased drug bioavailability. Methods: Floating microsphere were prepared by emulsion solvent diffusion method, using hydroxylpropyl methylcellulose (HPMC), ethyl cellulose (EC), Eudragit S 100 polymer in ...

  9. PLGA and PHBV Microsphere Formulations and Solid-State Characterization

    DEFF Research Database (Denmark)

    Yang, Chiming; Plackett, David; Needham, David

    2009-01-01

    To develop and characterize the solid-state properties of poly(DL-lactic-co-glycolic acid) (PLGA) and poly(3-hydroxybutyric acid-co-3-hydroxyvaleric acid) (PHBV) microspheres for the localized and controlled release of fusidic acid (FA). The effects of FA loading and polymer composition on the me...... of a DCM-FA-rich phase in the forming microsphere....

  10. Preparation of mesoporous zirconia microspheres as inert matrix

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Ting [State Key Laboratory of New Ceramics and Fine Processing, Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing, 100084 (China); Wang, Chen; Lv, Jinlong [Beijing Key Laboratory of Fine Ceramics, Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing, 100084 (China); Liang, Tongxiang, E-mail: txliang@tsinghua.edu.cn [State Key Laboratory of New Ceramics and Fine Processing, Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing, 100084 (China)

    2016-12-01

    Mesoporous zirconia microspheres, with a diameter of 900 μm, were prepared as an inert accelerator driven system (ADS) transmutation element matrix by the sol-gel method. The purpose of mesopores is to improve the adsorption capacity of inert matrix fuel (IMF) for minor actinides. The study indicated that the mesoporous zirconia performance was improved after the microspheres were hydrothermally treated at 150 °C, the specific surface area increased from 28.29 m{sup 2}/g to 61.28 m{sup 2}/g, and hydrothermal treatment avoided the cracking of the microspheres. Pre-decomposition of the organics during the hydrothermal process stabilized the mesoporous structure. The average pore diameter of mesoporous microsphere was 14.3 nm. - Highlights: • Mesoporous zirconia microspheres with a diameter of 900 μm were prepared as ADS transmutation element inert matrix. • The mesoporous performance was improved after the microspheres were hydrothermally treated at 150 °C. • The specific surface area increased from 28.29 m{sup 2}/g to 61.28 m{sup 2}/g. • The hydrothermal treatment could avoid the cracking of the microspheres. • The specific surface area of mesoporous microsphere was 61.28 m{sup 2}/g and the average pore diameter was 14.3 nm.

  11. Antibacterial activity of ciprofloxacin-loaded zein microsphere films

    International Nuclear Information System (INIS)

    Fu Jianxi; Wang Huajie; Zhou Yanqing; Wang Jinye

    2009-01-01

    Our aim was to produce an antibiotic-emitting coating composed of zein microspheres for the prevention of bacterial infection on implanted devices. Ciprofloxacin-loaded zein microspheres were prepared using a phase separation procedure, with particle sizes between 0.5 and 2 μm. Drug encapsulation and drug loading varied with the amount of both zein and ciprofloxacin, and the highest encapsulation efficiency was 8.27% (2 mg/ml ciprofloxacin and 20 mg/ml zein; n = 3). A ciprofloxacin-loaded zein microsphere film (CF-MS film) was generated via solvent evaporation. Continuous drug release from a trypsin-degraded microsphere film was observed for up to 28 days. The liberation of ciprofloxacin from the trypsin-degraded film and the biodegradation of the microsphere film were highly correlated. Proliferation assay of the growth of human umbilical vein endothelial cells (HUVECs) by the MTT method showed that the microsphere film had no toxicity when compared with cells grown on Corning culture plates alone and plates with a zein film alone. Quantification of bacteria adhesion showed that adhesion on the microsphere film is significantly suppressed. In addition, according to the results of bacterial growth tests, ciprofloxacin-loaded microsphere films maintained antibacterial activity for more than 6 days. In contrast, a control medium containing a zein film allowed constant bacterial growth. These results indicate that CF-MS films might be useful as antibacterial films on implanted devices.

  12. Apparatus for manufacturing ceramics microspheres for cementing applications

    NARCIS (Netherlands)

    2012-01-01

    A method and apparatus for manufacturing ceramic microspheres from industrial slag. The micro spheres have a particle size of about 38 microns to about 150 microns. The microspheres are used to create a cement slurry having a density of at least about Illbs/g. The resultant cement slurry may then be

  13. Controlling silk fibroin microspheres via molecular weight distribution

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Dong-Mei; Pan, Jue-Jing; Wang, Qun; Liu, Xin-Fang; Wang, Hui [National Engineering Laboratory for Modern Silk, College for Textile and Clothing Engineering, Soochow University, Suzhou, Jiangsu 215123 (China); Zhang, Ke-Qin, E-mail: kqzhang@suda.edu.cn [National Engineering Laboratory for Modern Silk, College for Textile and Clothing Engineering, Soochow University, Suzhou, Jiangsu 215123 (China); Research Center of Cooperative Innovation for Functional Organic/Polymer Material Micro/Nanofabrication, Soochow University, Suzhou, Jiangsu 215123 (China)

    2015-05-01

    Silk fibroin (SF) microspheres were produced by salting out SF solution via the addition of potassium phosphate buffer solution (K{sub 2}HPO{sub 4}–KH{sub 2}PO{sub 4}). The morphology, size and polydispersity of SF microspheres were adjusted by changing the molecular weight (MW) distribution and concentration of SF, as well as the ionic strength and pH of the buffer solution. Changing the conditions under which the SF fiber dissolved in the Lithium Boride (LiBr) solution resulted in altering the MW distribution of SF solution. Under optimal salting-out conditions (ionic strength > 0.7 M and pH > 7) and using a smaller and narrower SF MW distribution, SF microspheres with smoother shapes and more uniform sizes were produced. Meanwhile, the size and polydispersity of the microspheres increased when the SF concentration was increased from 0.25 mg/mL to 20 mg/mL. The improved SF microspheres, obtained by altering the distribution of molecular weight, have potential in drug and gene delivery applications. - Highlights: • MW distribution was changed by applying different dissolving methods of SF fiber. • Smaller and narrower MW distribution improves the quality of SF microspheres. • Size and polydispersity of microspheres increase as SF concentration increases. • Improved SF microspheres have potential in drug and gene delivery applications.

  14. Porous-wall hollow glass microspheres as carriers for biomolecules

    Science.gov (United States)

    Li, Shuyi; Dynan, William S; Wicks, George; Serkiz, Steven

    2013-09-17

    The present invention includes compositions of porous-wall hollow glass microspheres and one or more biomolecules, wherein the one or more biomolecules are positioned within a void location within the hollow glass microsphere, and the use of such compositions for the diagnostic and/or therapeutic delivery of biomolecules.

  15. Antibacterial activity of ciprofloxacin-loaded zein microsphere films

    Energy Technology Data Exchange (ETDEWEB)

    Fu Jianxi [Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 354 Fenglin Road, Shanghai 200032 (China); Henan Normal University, 46 East Construction Road, Xinxiang, Henan 453007 (China); Wang Huajie [College of Life Science and Biotechnology, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai 200030 (China); Zhou Yanqing [Henan Normal University, 46 East Construction Road, Xinxiang, Henan 453007 (China); Wang Jinye, E-mail: jywang@mail.sioc.ac.cn [Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 354 Fenglin Road, Shanghai 200032 (China); College of Life Science and Biotechnology, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai 200030 (China)

    2009-05-05

    Our aim was to produce an antibiotic-emitting coating composed of zein microspheres for the prevention of bacterial infection on implanted devices. Ciprofloxacin-loaded zein microspheres were prepared using a phase separation procedure, with particle sizes between 0.5 and 2 {mu}m. Drug encapsulation and drug loading varied with the amount of both zein and ciprofloxacin, and the highest encapsulation efficiency was 8.27% (2 mg/ml ciprofloxacin and 20 mg/ml zein; n = 3). A ciprofloxacin-loaded zein microsphere film (CF-MS film) was generated via solvent evaporation. Continuous drug release from a trypsin-degraded microsphere film was observed for up to 28 days. The liberation of ciprofloxacin from the trypsin-degraded film and the biodegradation of the microsphere film were highly correlated. Proliferation assay of the growth of human umbilical vein endothelial cells (HUVECs) by the MTT method showed that the microsphere film had no toxicity when compared with cells grown on Corning culture plates alone and plates with a zein film alone. Quantification of bacteria adhesion showed that adhesion on the microsphere film is significantly suppressed. In addition, according to the results of bacterial growth tests, ciprofloxacin-loaded microsphere films maintained antibacterial activity for more than 6 days. In contrast, a control medium containing a zein film allowed constant bacterial growth. These results indicate that CF-MS films might be useful as antibacterial films on implanted devices.

  16. Formulation and Evaluation of Microspheres Based on Gelatin ...

    African Journals Online (AJOL)

    Formulation and Evaluation of Microspheres Based on Gelatin-Mucin Admixtures for the Rectal Delivery of Cefuroxime Sodium. K C Ofokansi, M U Adikwu. Abstract. Purpose: Swellable microspheres based on polymers or their admixtures are frequently employed as drug delivery systems to achieve a controlled release ...

  17. Microspheres with Ultrahigh Holmium Content for Radioablation of Malignancies

    NARCIS (Netherlands)

    Bult, W.; Seevinck, P.R.; Krijger, G.C.; Visser, T.; Kroon-Batenburg, L.M.J.; Bakker, C.J.G.; Hennink, W.E.; van het Schip, A.D.; Nijsen, J.F.W.

    2009-01-01

    The aim of this study was to develop microspheres with an ultra high holmium content which can be neutron activated for radioablation of malignancies. These microspheres are proposed to be delivered selectively through either intratumoral injections into solid tumors or administered via an

  18. Microspheres with ultrahigh holmium content for radioablation of malignancies

    NARCIS (Netherlands)

    Bult, W; Seevinck, P R; Krijger, G C; Visser, T; Kroon-Batenburg, L M J; Bakker, C J G; Hennink, W E; van het Schip, A D; Nijsen, J F W

    PURPOSE: The aim of this study was to develop microspheres with an ultra high holmium content which can be neutron activated for radioablation of malignancies. These microspheres are proposed to be delivered selectively through either intratumoral injections into solid tumors or administered via an

  19. Microspheres with Ultrahigh Holmium Content for Radioablation of Malignancies

    NARCIS (Netherlands)

    Bult, W.; Seevinck, P.R.; Krijger, G.C.; Visser, T.; Kroon-Batenburg, L.M.J.; Bakker, C.J.G.; Hennink, W.E.; Van het Schip, A.D.; Nijsen, J.F.W.

    Purpose The aim of this study was to develop microspheres with an ultra high holmium content which can be neutron activated for radioablation of malignancies. These microspheres are proposed to be delivered selectively through either intratumoral injections into solid tumors or administered via an

  20. Receptor scintigraphy using the Tc-99M-labelled somatostatin analogue EDDA-TRYCINE-HYNIC-TOC: clinical results in different tumor types and comparison with In-111 DOTATOC during Y-90 DOTATOC radioreceptor therapy

    International Nuclear Information System (INIS)

    Baum, R.P.; Schmuecking, M.; Fischer, S.; Przetak, C.; Niesen, A.; Maecke, H.R.

    2002-01-01

    Aim: To evaluate Tc-99m EDDA-TRYCINE-HYNIC-TOC in patients with somatostatin receptor positive tumours (staging, pre-therapeutic dosimetry for radioreceptor therapy and restaging after therapy) in comparison with In-111 DOTATOC. Material and Methods: The Tc-99m labelled somatostatin analogue was synthesized by an optimized procedure in our pharmaceutical laboratory using lyophilized kits (radiochemical purity by HPLC, TLC > 95%, product stability in vitro 4 to 6h). So far, 58 patients (60 examinations) were studied after injection of 580-890 MBq (median 673 MBq) EDDA-TRYCINE-HYNIC-TOC. The histologically proven tumours were neuroendocrine neoplasias, renal carcinomas, bronchial carcinoma, mesothelioma and malignant fibrous histiocytoma. The imaging protocol consisted of whole-body scans and planar images of the tumor region (15 min, 1 h, 2 h, 4 h, 8 h, 24 h p.i.) and additionally SPECT-images (1 h und 4 h p.i.). For semi-quantitative assessment, individual regions of interest (ROI) were drawn in order to generate time-activity curves and to calculate tumour-to-tissue/background ratios which were compared by visual grading (scala 0 to 3+). Furthermore, pharmacokinetic analyses were carried out (radioactivity kinetics in plasma and urine). In some selected patients, image fusion of whole-body scans was performed with CT and/or MRT and/or PET using a NUD software and a HERMES computer. Results: 10 out of 58 patients showed an intense tracer accumulation in the SSTR-positive tumours (visual 3+, tumour/background ratio >2,5). In these patients, radioreceptor therapy was carried out using Y-90 DOTATOC (simultaneous injection von 150 MBq In-111 DOTATOC). All pretherapeutic scans with the Tc-99m labelled ligand (4 h p.i.) showed a similar overall pattern of biodistribution and tumour uptake in comparison to the therapy scans with In-111 / Y-90 DOTATOC (24 h p.i.). The Tc-99m EDDA-TRYCINE-HYNIC-TOC scans (incl. SPECT) offered superior imaging properties with earlier tumour

  1. Receptor imaging with a new Tc-99m labelled somatostatin analogue (Tc-99m EDDA-TRYCINE-HYNIC-TOC): first clinical results and comparison with In-111 Dotatoc during radioreceptor therapy with Y-90 Dotatoc

    International Nuclear Information System (INIS)

    Baum, R.P.; Schmuecking, M.; Fischer, S.; Przetak, C.; Niesen, A.; Maecke, H.R.

    2002-01-01

    Full text: To evaluate Tc-99m EDDA-TRYCINE-HYNIC-TOC (TET-H-TOC) in patients with somatostatin receptor (SSTR)-positive tumors (staging, pretherapeutic indication for radioreceptor therapy and restaging after therapy) in comparison with In-111 DOTATOC. The Tc-99m labelled somatostatin analogue was synthesized by an optimized procedure in our pharmaceutical lab using lyophilized kits (radiochemical purity by HPLC, TLC > 95 %, product stability in vitro 4 to 6 h). So far, 46 patients (53 examinations) were studied after injection of 580-890 MBq (median 673 MBq) TET-H-TOC. The histologically proven tumors were endocrine neoplasias, renal carcinomas, bronchial carcinoma, mesothelioma and malignant fibrous histiocytoma. The imaging protocol consisted of whole-body scans and planar images of the tumor region (15 min, 1 h, 2 h, 4 h, 8 h, 24 h p.i.) and additionally SPECT-images (1 h and 4 h p.i.). For semi-quantitative assessment, individual regions of interest (ROI) were drawn in order to generate time-activity curves and to calculate tumor-to-tissue/background ratios which were compared by visual grading (scale 0 to 3+). Furthermore, pharmacokinetic analyses were carried out (radioactivity kinetics in plasma and urine). In some selected patients, image fusion of the whole-body scans was performed with CT and/or MRT and/or PET using a HERMES computer. 7 out of 46 patients showed an intense tracer accumulation in the SSTR-positive tumors (visual 3+, tumor / background ratio >2,5). In these patients, radioreceptor therapy was carried out using Y-90 DOTATOC (simultaneous injection of 150 MBq In-111 DOTATOC). All pretherapeutic scans with the Tc-99m labelled ligand (4 h p.i.) showed a similar overall pattern of biodistribution and tumor uptake in comparison to the therapy scans with In-111 / Y-90 DOTATOC 24 h p.i. The Tc-99m EDDA-HYNIC-TOC scans (incl. SPECT) offered superior imaging properties with earlier tumor visualization (all lesions were detected 1 h p.i.) as compared

  2. Optimization of sustained release aceclofenac microspheres using response surface methodology

    Energy Technology Data Exchange (ETDEWEB)

    Deshmukh, Rameshwar K.; Naik, Jitendra B., E-mail: jitunaik@gmail.com

    2015-03-01

    Polymeric microspheres containing aceclofenac were prepared by single emulsion (oil-in-water) solvent evaporation method using response surface methodology (RSM). Microspheres were prepared by changing formulation variables such as the amount of Eudragit® RS100 and the amount of polyvinyl alcohol (PVA) by statistical experimental design in order to enhance the encapsulation efficiency (E.E.) of the microspheres. The resultant microspheres were evaluated for their size, morphology, E.E., and in vitro drug release. The amount of Eudragit® RS100 and the amount of PVA were found to be significant factors respectively for determining the E.E. of the microspheres. A linear mathematical model equation fitted to the data was used to predict the E.E. in the optimal region. Optimized formulation of microspheres was prepared using optimal process variables setting in order to evaluate the optimization capability of the models generated according to IV-optimal design. The microspheres showed high E.E. (74.14 ± 0.015% to 85.34 ± 0.011%) and suitably sustained drug release (minimum; 40% to 60%; maximum) over a period of 12 h. The optimized microspheres formulation showed E.E. of 84.87 ± 0.005 with small error value (1.39). The low magnitudes of error and the significant value of R{sup 2} in the present investigation prove the high prognostic ability of the design. The absence of interactions between drug and polymers was confirmed by Fourier transform infrared (FTIR) spectroscopy. Differential scanning calorimetry (DSC) and X-ray powder diffractometry (XRPD) revealed the dispersion of drug within microspheres formulation. The microspheres were found to be discrete, spherical with smooth surface. The results demonstrate that these microspheres could be promising delivery system to sustain the drug release and improve the E.E. thus prolong drug action and achieve the highest healing effect with minimal gastrointestinal side effects. - Highlights: • Aceclofenac microspheres

  3. Preparation and Characterization of Fluorescent SiO2 Microspheres

    Science.gov (United States)

    Xu, Cui; Zhang, Hao; Guan, Ruifang

    2018-01-01

    Fluorescent compound without typical fluorophores was synthesized with citric acid (CA) and aminopropyltriethoxysilane (APTS) firstly, and then it was grafted to the surface of the prepared SiO2 microspheres by chemical reaction. The fluorescent SiO2 microspheres with good fluorescent properties were obtained by optimizing the reaction conditions. And the morphology and structure of the fluorescent SiO2 microspheres have been characterized by scanning electron microscopy (SEM) and fourier transform infrared (FTIR) spectroscopy. The results showed that the preparation of fluorescent SiO2 microspheres have good monodispersity and narrow particle size distribution. Moreover, the fluorescent SiO2 microspheres can be applied to detect Fe3+ in aqueous solution, prepare fluorescent SiO2 rubber, and have potential to be applied in the fluorescent labeling and fingerprint appearing technique fields.

  4. Study on the Degradation of Polylactide Microsphere In Vitro

    Institute of Scientific and Technical Information of China (English)

    HeYing; WeiShuli

    2001-01-01

    This report concentrated on the rules and mechanism of the degradation of polylactide and the microspheres. The rate of degradation was assessed with five methods: observation of microsphere surface morphology by SEM, determination of the weight loss of the microspheres, determination of the molecular mass of the polymers by GPC, determination of pH and determination of the contents of lactic acid by UV spectrophotometry. The degradation of polylactide microspheres showed two-phase characteristics. At the early stage of the degradation, the high molecular mass polymers were cleaved into lower molecular mass fractions and at the late stage, there was a period of erosion and weight loss of the microspheres. The degradation was much slower for polymers with a higher molecular mass. The polylactide degradation showed good regularity.

  5. Hollow porous-wall glass microspheres for hydrogen storage

    Science.gov (United States)

    Heung, Leung K.; Schumacher, Ray F.; Wicks, George G.

    2010-02-23

    A porous wall hollow glass microsphere is provided having a diameter range of between 1 to 200 microns, a density of between 1.0 to 2.0 gm/cc, a porous-wall structure having wall openings defining an average pore size of between 10 to 1000 angstroms, and which contains therein a hydrogen storage material. The porous-wall structure facilitates the introduction of a hydrogen storage material into the interior of the porous wall hollow glass microsphere. In this manner, the resulting hollow glass microsphere can provide a membrane for the selective transport of hydrogen through the porous walls of the microsphere, the small pore size preventing gaseous or liquid contaminants from entering the interior of the hollow glass microsphere.

  6. Pre-operative evaluation for thorax surgery

    International Nuclear Information System (INIS)

    Silva Luis, Saenz; Morales, Oscar Alberto

    2002-01-01

    A pre-operative analysis of the function of the breathing system is made in the patient that will be taken to thorax surgery. The paper includes risk factors, pre-operative clinical evaluation and of breathing and cardiovascular system

  7. Mesoporous metal oxide microsphere electrode compositions and their methods of making

    Science.gov (United States)

    Parans Paranthaman, Mariappan; Bi, Zhonghe; Bridges, Craig A.; Brown, Gilbert M.

    2017-04-11

    Compositions and methods of making are provided for treated mesoporous metal oxide microspheres electrodes. The compositions include microspheres with an average diameter between about 200 nanometers and about 10 micrometers and mesopores on the surface and interior of the microspheres. The methods of making include forming a mesoporous metal oxide microsphere composition and treating the mesoporous metal oxide microspheres by at least annealing in a reducing atmosphere, doping with an aliovalent element, and coating with a coating composition.

  8. Long pulse microsphere experiments at 3 TW

    International Nuclear Information System (INIS)

    Boyle, M.J.; Attwood, D.T.; Brooks, K.M.

    1977-01-01

    Previous 1.06 μm laser implosion experiments have explored the parameter space associated with microsphere targets of typically less than 100 psec. Exploding pusher experiments have now been performed using long pulses (100 to 200 psec FWHM), and large diameter (100 to 150 μm) targets on the 3 TW Argus laser facility. Absorption, transport, implosion and neutron and α yield characteristics are discussed and compared with earlier short pulse results. The observed neutron yields are discussed in light of the temporal mismatch between the absorption and implosion time scales imposed by the large diameter, long pulse conditions

  9. Preoperative staging of rectal cancer

    International Nuclear Information System (INIS)

    Schaefer, A.O.; Baumann, T.; Pache, G.; Langer, M.; Wiech, T.

    2007-01-01

    Accurate preoperative staging of rectal cancer is crucial for therapeutic decision making, as local tumor extent, nodal status, and patterns of metastatic spread are directly associated with different treatment strategies. Recently, treatment approaches have been widely standardized according to large studies and consensus guidelines. Introduced by Heald, total mesorectal excision (TME) is widely accepted as the surgical procedure of choice to remove the rectum together with its enveloping tissues and the mesorectal fascia. Neoadjuvant radiochemotherapy also plays a key role in the treatment of locally advanced stages, while the use of new drugs will lead to a further improvement in oncological outcome. Visualization of the circumferential resection margin is the hallmark of any preoperative imaging and a prerequisite for high-quality TME surgery. The aim of this article is to present an overview on current cross-sectional imaging with emphasis on magnetic resonance imaging. Future perspectives in rectal cancer imaging are addressed. (orig.)

  10. Interventions for preoperative smoking cessation

    DEFF Research Database (Denmark)

    Thomsen, Thordis; Villebro, N.; Møller, Ann Merete

    2010-01-01

    Background Smokers have a substantially increased risk of postoperative complications. Preoperative smoking intervention may be effective in decreasing this incidence, and surgery may constitute a unique opportunity for smoking cessation interventions. Objectives The objective of this review...... was to assess the effect of preoperative smoking intervention on smoking cessation at the time of surgery and 12 months postoperatively and on the incidence of postoperative complications. Search strategy The specialized register of the Cochrane Tobacco Addiction Group was searched using the free text...... and keywords (surgery) or (operation) or (anaesthesia) or (anesthesia). MEDLINE, EMBASE and CINAHL were also searched, combining tobacco- and surgery-related terms. Most recent search April 2010. Selection criteria Randomized controlled trials that recruited people who smoked prior to surgery, offered...

  11. FFTF preoperational survey. Program report

    International Nuclear Information System (INIS)

    Twitty, B.L.; Bicehouse, H.J.

    1980-12-01

    The FFTF will become operational with criticality early in 1980. This facility is composed of the test reactor, fuel examination cells, expended fuel storage systems and fuel handling systems. The reactor and storage systems are sodium-cooled with the heat load dumped to the ambient air through heat exchangers. In order to assure that the operation of the FFTF has minimal impact on the environment, a monitoring program has been established. Prior to operation of a new facility, a preoperational environmental survey is required. It is the purpose of this report to briefly describe the environmental survey program and to provide the background data obtained during the preoperational phase of the survey program. Nine stations in the program of particular importance to FFTF are discussed in detail with results of monitoring given. No unexplained trends were noted

  12. The value of preoperative planning.

    Science.gov (United States)

    Graves, Matt L

    2013-10-01

    "Better to throw your disasters into the waste paper basket than to consign your patients to the scrap heap" has been a proverb of Jeff Mast, one of the greatest fracture and deformity surgeons in the history of our specialty. Stated slightly more scientifically, one of the major values of simulation is that it allows one to make mistakes in a consequence-free environment. Preoperative planning is the focus of this article. The primary goal is not to provide you with a recipe of how to steps. Rather, the primary goal of this article is to explain why preoperative planning should be standard, to clarify what should be included, and to provide examples of what can happen when planning is ignored. At the end of this, we should all feel the need to approach fracture care more intellectually with forethought, both in our own practices and in our educational system.

  13. [Preoperative fasting guidelines: an update].

    Science.gov (United States)

    López Muñoz, A C; Busto Aguirreurreta, N; Tomás Braulio, J

    2015-03-01

    Anesthesiology societies have issued various guidelines on preoperative fasting since 1990, not only to decrease the incidence of lung aspiration and anesthetic morbidity, but also to increase patient comfort prior to anesthesia. Some of these societies have been updating their guidelines, as such that, since 2010, we now have 2 evidence-based preoperative fasting guidelines available. In this article, an attempt is made to review these updated guidelines, as well as the current instructions for more controversial patients such as infants, the obese, and a particular type of ophthalmic surgery. Copyright © 2014 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Preoperative nutrition therapy - novel developments

    OpenAIRE

    Ljungqvist, Olle; Nygren, Jonas; Hausel, Jonatan; Thorell, Anders

    2000-01-01

    Elective surgery has until recently been performed in the overnight fasted state in order to reduce the risk of aspiration of gastric content during the induction of anaesthesia. However, in order to increase the preoperative well-being of surgical patients, most western countries have changed their routines during the last 10-15 years, allowing intake of clear fluids up to 2 hours before anaesthesia in most patients. Animal studies have demonstrated that undergoing different situations of st...

  15. Insulin delivery through nasal route using thiolated microspheres.

    Science.gov (United States)

    Nema, Tarang; Jain, Ashish; Jain, Aviral; Shilpi, Satish; Gulbake, Arvind; Hurkat, Pooja; Jain, Sanjay K

    2013-01-01

    The aim of the present study was to investigate the potential of developed thiolated microspheres for insulin delivery through nasal route. In the present study, cysteine was immobilized on carbopol using EDAC. A total of 269.93 µmol free thiol groups per gram polymer were determined. The prepared nonthiolated and thiolated microspheres were studied for particle shape, size, drug content, swellability, mucoadhesion and in vitro insulin release. The thiolated microspheres exhibited higher mucoadhesion due to formation of covalent bonds via disulfide bridges with the mucus gel layer. Drug permeation through goat nasal mucosa of nonthiolated and thiolated microspheres were found as 52.62 ± 2.4% and 78.85 ± 3.1% in 6 h, respectively. Thiolated microspheres bearing insulin showed better reduction in blood glucose level (BGL) in comparison to nonthiolated microspheres as 31.23 ± 2.12% and 75.25 ± 0.93% blood glucose of initial BGL were observed at 6 h after nasal delivery of thiolated and nonthiolated microspheres in streptozotocin-induced diabetic rabbits.

  16. Magnetic poly(glycidyl methacrylate) microspheres for protein capture.

    Science.gov (United States)

    Koubková, Jana; Müller, Petr; Hlídková, Helena; Plichta, Zdeněk; Proks, Vladimír; Vojtěšek, Bořivoj; Horák, Daniel

    2014-09-25

    The efficient isolation and concentration of protein antigens from complex biological samples is a critical step in several analytical methods, such as mass spectrometry, flow cytometry and immunochemistry. These techniques take advantage of magnetic microspheres as immunosorbents. The focus of this study was on the development of new superparamagnetic polymer microspheres for the specific isolation of the tumor suppressor protein p53. Monodisperse macroporous poly(glycidyl methacrylate) (PGMA) microspheres measuring approximately 5 μm and containing carboxyl groups were prepared by multistep swelling polymerization of glycidyl methacrylate (GMA), 2-[(methoxycarbonyl)methoxy]ethyl methacrylate (MCMEMA) and ethylene dimethylacrylate (EDMA) as a crosslinker in the presence of cyclohexyl acetate as a porogen. To render the microspheres magnetic, iron oxide was precipitated within their pores; the Fe content in the particles received ∼18 wt%. Nonspecific interactions between the magnetic particles and biological media were minimized by coating the microspheres with poly(ethylene glycol) (PEG) terminated by carboxyl groups. The carboxyl groups of the magnetic PGMA microspheres were conjugated with primary amino groups of mouse monoclonal DO-1 antibody using conventional carbodiimide chemistry. The efficiency of protein p53 capture and the degree of nonspecific adsorption on neat and PEG-coated magnetic microspheres were determined by western blot analysis. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Measurement of thermal diffusivity of depleted uranium metal microspheres

    Science.gov (United States)

    Humrickhouse-Helmreich, Carissa J.; Corbin, Rob; McDeavitt, Sean M.

    2014-03-01

    The high void space of nuclear fuels composed of homogeneous uranium metal microspheres may allow them to achieve ultra-high burnup by accommodating fuel swelling and reducing fuel/cladding interactions; however, the relatively low thermal conductivity of microsphere nuclear fuels may limit their application. To support the development of microsphere nuclear fuels, an apparatus was designed in a glovebox and used to measure the apparent thermal diffusivity of a packed bed of depleted uranium (DU) microspheres with argon fill in the void spaces. The developed Crucible Heater Test Assembly (CHTA) recorded radial temperature changes due to an initial heat pulse from a central thin-diameter cartridge heater. Using thermocouple positions and time-temperature data, the apparent thermal diffusivity was calculated. The thermal conductivity of the DU microspheres was calculated based on the thermal diffusivity from the CHTA, known material densities and specific heat capacities, and an assumed 70% packing density based on prior measurements. Results indicate that DU metal microspheres have very low thermal conductivity, relative to solid uranium metal, and rapidly form an oxidation layer even in a low oxygen environment. At 500 °C, the thermal conductivity of the DU metal microsphere bed was 0.431 ± 0.0560 W/m-K compared to the literature value of approximately 32 W/m-K for solid uranium metal.

  18. Measurement of thermal diffusivity of depleted uranium metal microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Humrickhouse-Helmreich, Carissa J., E-mail: carissahelmreich@tamu.edu [Texas A and M University, Department of Nuclear Engineering, 337 Zachry Engineering Center, 3133 TAMU, College Station, TX 77843 (United States); Corbin, Rob, E-mail: rcorbin@terrapower.com [TerraPower, LLC, 330 120th Ave NE, Suite 100, Bellevue, WA 98005 (United States); McDeavitt, Sean M., E-mail: mcdeavitt@tamu.edu [Texas A and M University, Department of Nuclear Engineering, 337 Zachry Engineering Center, 3133 TAMU, College Station, TX 77843 (United States)

    2014-03-15

    The high void space of nuclear fuels composed of homogeneous uranium metal microspheres may allow them to achieve ultra-high burnup by accommodating fuel swelling and reducing fuel/cladding interactions; however, the relatively low thermal conductivity of microsphere nuclear fuels may limit their application. To support the development of microsphere nuclear fuels, an apparatus was designed in a glovebox and used to measure the apparent thermal diffusivity of a packed bed of depleted uranium (DU) microspheres with argon fill in the void spaces. The developed Crucible Heater Test Assembly (CHTA) recorded radial temperature changes due to an initial heat pulse from a central thin-diameter cartridge heater. Using thermocouple positions and time–temperature data, the apparent thermal diffusivity was calculated. The thermal conductivity of the DU microspheres was calculated based on the thermal diffusivity from the CHTA, known material densities and specific heat capacities, and an assumed 70% packing density based on prior measurements. Results indicate that DU metal microspheres have very low thermal conductivity, relative to solid uranium metal, and rapidly form an oxidation layer even in a low oxygen environment. At 500 °C, the thermal conductivity of the DU metal microsphere bed was 0.431 ± 0.0560 W/m-K compared to the literature value of approximately 32 W/m-K for solid uranium metal.

  19. Preparation of nano-hydroxyapatite/poly(l-lactide) biocomposite microspheres

    International Nuclear Information System (INIS)

    Qiu Xueyu; Han Yadong; Zhuang Xiuli; Chen Xuesi; Li Yuesheng; Jing Xiabin

    2007-01-01

    Nano-hydroxyapatite (HA)/poly(l-lactide) (PLLA) composite microspheres with relatively uniform size distribution were prepared by a solid-in-oil-in-water (s/o/w) emusion solvent evaporation method. The encapsulation of the HA nanopaticles in microshperes was significantly improved by grafting PLLA on the surface of the HA nanoparticles (p-HA) during emulsion process. This procedure gave a possibility to obtain p-HA/PLLA composite microspheres with uniform morphology and the encapsulated p-HA nanoparticle loading reached up to 40 wt% (33 wt% of pure HA) in the p-HA/PLLA composite microspheres. The microstructure of composite microspheres from core-shell to single phase changed with the variation of p-HA to PLLA ratios. p-HA/PLLA composite microspheres with the diameter range of 2-3 μm were obtained. The entrapment efficiency of p-HA in microspheres could high up to 90 wt% and that of HA was only 13 wt%. Surface and bulk characterizations of the composite microspheres were performed by measurements such as wide angle X-ray diffraction (WAXD), thermal gravimetric analysis (TGA), environmental scanning electron microscope (ESEM) and transmission electron microscopy (TEM)

  20. Current knowledge on biodegradable microspheres in drug delivery.

    Science.gov (United States)

    Prajapati, Vipul D; Jani, Girish K; Kapadia, Jinita R

    2015-08-01

    Biodegradable microspheres have gained popularity for delivering a wide variety of molecules via various routes. These types of products have been prepared using various natural and synthetic biodegradable polymers through suitable techniques for desired delivery of various challenging molecules. Selection of biodegradable polymers and technique play a key role in desired drug delivery. This review describes an overview of the fundamental knowledge and status of biodegradable microspheres in effective delivery of various molecules via desired routes with consideration of outlines of various compendial and non-compendial biodegradable polymers, formulation techniques and release mechanism of microspheres, patents and commercial biodegradable microspheres. There are various advantages of using biodegradable polymers including promise of development with different types of molecules. Biocompatibility, low dosage and reduced side effects are some reasons why usage biodegradable microspheres have gained in popularity. Selection of biodegradable polymers and formulation techniques to create microspheres is the biggest challenge in research. In the near future, biodegradable microspheres will become the eco-friendly product for drug delivery of various genes, hormones, proteins and peptides at specific site of body for desired periods of time.

  1. Measurement of thermal diffusivity of depleted uranium metal microspheres

    International Nuclear Information System (INIS)

    Humrickhouse-Helmreich, Carissa J.; Corbin, Rob; McDeavitt, Sean M.

    2014-01-01

    The high void space of nuclear fuels composed of homogeneous uranium metal microspheres may allow them to achieve ultra-high burnup by accommodating fuel swelling and reducing fuel/cladding interactions; however, the relatively low thermal conductivity of microsphere nuclear fuels may limit their application. To support the development of microsphere nuclear fuels, an apparatus was designed in a glovebox and used to measure the apparent thermal diffusivity of a packed bed of depleted uranium (DU) microspheres with argon fill in the void spaces. The developed Crucible Heater Test Assembly (CHTA) recorded radial temperature changes due to an initial heat pulse from a central thin-diameter cartridge heater. Using thermocouple positions and time–temperature data, the apparent thermal diffusivity was calculated. The thermal conductivity of the DU microspheres was calculated based on the thermal diffusivity from the CHTA, known material densities and specific heat capacities, and an assumed 70% packing density based on prior measurements. Results indicate that DU metal microspheres have very low thermal conductivity, relative to solid uranium metal, and rapidly form an oxidation layer even in a low oxygen environment. At 500 °C, the thermal conductivity of the DU metal microsphere bed was 0.431 ± 0.0560 W/m-K compared to the literature value of approximately 32 W/m-K for solid uranium metal

  2. Nanomechanics of biocompatible hollow thin-shell polymer microspheres.

    Science.gov (United States)

    Glynos, Emmanouil; Koutsos, Vasileios; McDicken, W Norman; Moran, Carmel M; Pye, Stephen D; Ross, James A; Sboros, Vassilis

    2009-07-07

    The nanomechanical properties of biocompatible thin-shell hollow polymer microspheres with approximately constant ratio of shell thickness to microsphere diameter were measured by nanocompression tests in aqueous conditions. These microspheres encapsulate an inert gas and are used as ultrasound contrast agents by releasing free microbubbles in the presence of an ultrasound field as a result of free gas leakage from the shell. The tests were performed using an atomic force microscope (AFM) employing the force-distance curve technique. An optical microscope, on which the AFM was mounted, was used to guide the positioning of tipless cantilevers on top of individual microspheres. We performed a systematic study using several cantilevers with spring constants varying from 0.08 to 2.3 N/m on a population of microspheres with diameters from about 2 to 6 microm. The use of several cantilevers with various spring constants allowed a systematic study of the mechanical properties of the microsphere thin shell at different regimes of force and deformation. Using thin-shell mechanics theory for small deformations, the Young's modulus of the thin wall material was estimated and was shown to exhibit a strong size effect: it increased as the shell became thinner. The Young's modulus of thicker microsphere shells converged to the expected value for the macroscopic bulk material. For high applied forces, the force-deformation profiles showed a reversible and/or irreversible nonlinear behavior including "steps" and "jumps" which were attributed to mechanical instabilities such as buckling events.

  3. Brownian dynamics simulations of insulin microspheres formation

    Science.gov (United States)

    Li, Wei; Chakrabarti, Amit; Gunton, James

    2010-03-01

    Recent experiments have indicated a novel, aqueous process of microsphere insulin fabrication based on controlled phase separation of protein from water-soluble polymers. We investigate the insulin microsphere crystal formation from insulin-PEG-water systems via 3D Brownian Dynamics simulations. We use the two component Asakura-Oosawa model to simulate the kinetics of this colloid polymer mixture. We first perform a deep quench below the liquid-crystal boundary that leads to fractal formation. We next heat the system to obtain a break-up of the fractal clusters and subsequently cool the system to obtain a spherical aggregation of droplets with a relatively narrow size distribution. We analyze the structure factor S(q) to identify the cluster dimension. S(q) crosses over from a power law q dependence of 1.8 (in agreement with DLCA) to 4 as q increases, which shows the evolution from fractal to spherical clusters. By studying the bond-order parameters, we find the phase transition from liquid-like droplets to crystals which exhibit local HCP and FCC order. This work is supported by grants from the NSF and Mathers Foundation.

  4. Thyroid artery embolization with microspheres for hyperthyroidism

    International Nuclear Information System (INIS)

    Du Yahui; Zhong Chenfu; Chen Weijun; Zhang Ying; Luo Jun; Li Xiaoguang; Cao Junjie; Gan Changli; Cao Junjie; Gan Changli

    2006-01-01

    Objective: To evaluate the method and efficacy of thyroid artery embolization as a new therapy for hyperthyroidism. Methods: Thirteen patients with hyperthyroidism underwent selective thyroid artery embolization. Totally 25 thyroid arteries were embolized with microspheres. The indications for this therapy were as followings: 1) To give hyperthyroid patients having an alternative for surgical and 131 I treatment, and 2) To provide a new method for those clinically being difficult to get control with medicine. Results: Serum level of thyroid hormones dropped significantly[T3 from 2.84-9.0 ng/ml to 0.8-2.2 ng/ml, T4 from 162.9-277.2 ng/ml to 50-126 ng/ml] and symptoms of hyperthyroidism were under control in 12 patients within 1 month after the embolization. One patient remained no change 1 month later and refused to be embolized again. The symptoms of twelve patients were effectively controlled through low dose antithyroid medication for more than 6 months follow up with no serious complications. Conclusion: Thyroid artery embolization with microspheres is an effective alternative for surgical and 131 I treatment of hyperthyroidism. (authors)

  5. Preparation and properties of polyvinyl alcohol microspheres

    International Nuclear Information System (INIS)

    Campbell, J.H.; Grens, J.Z.; Poco, J.F.; Ives, B.H.

    1986-06-01

    Polyvinyl alcohol (PVA) microspheres, having a size range of ∼150- to 250-μm diameter with 1- to 5-μm wall thickness, have been fabricated using a solution droplet technique. The spheres were developed for possible use on the Lawrence Livermore National Laboratory (LLNL) Inertial Confinement Fusion (ICF) Program. PVA, a polymer chosen based on earlier survey work carried out at KMS Fusion, Inc., has good strength, low hydrogen permeability, is optically transparent, and water soluble. The latter property makes it safe and easy to use in our droplet generator system. A unique dual-orifice droplet generator was used to prepare the spheres. The droplet generator operating conditions and the column processing parameters were chosen using results from our 1-D model calculations as a guide. The polymer microsphere model is an extension of the model we developed to support the glass sphere production. After preparation, the spheres were physically characterized for surface quality, sphericity, wall thickness (and uniformity), and size. We also determined the buckling pressure for both uncoated and CH-coated spheres. Radiation stability to beta decay (from tritium) was evaluated by exposing the spheres to a 7-keV electron beam. The results from these and other physical property measurements are presented in this report

  6. Storage stability of biodegradable polyethylene glycol microspheres

    Science.gov (United States)

    Jain, Era; Sheth, Saahil; Polito, Kristen; Sell, Scott A.; Zustiak, Silviya P.

    2017-10-01

    Degradable hydrogel microspheres are popular choices for multiple biomedical applications, including drug, protein, or cell carriers for minimally invasive delivery. Clinical transitioning of such new, sensitive pharmaceutical preparations requires investigation of storage methods that retain key properties for extended time. In this study, we sought to determine the influence of seven common storage conditions on the physical and mechanical properties of degradable polyethylene glycol (PEG) hydrogel microspheres: 25 °C, 4 °C, -80 °C, lyophilization/-20 °C, dimethyl sulfoxide/-80 °C, dimethyl sulfoxide/lyophilization/-20 °C, vacuum/-20 °C. We have outlined the storage conditions in detail and explained their effect on swelling ratio, stiffness and degradation rate post-storage. Additionally, we have implemented protein-loaded hydrogels to evaluate the effect of storage conditions on diffusivity as well as protein stability post-storage. We found that hydrogels could be stored short-term (1-4 d) under moist conditions (i.e. storage without drying) without a substantial loss of properties. For extended storage (7-28 d), they could be stored either at  -80 °C (moist condition) or vacuum drying (dry condition).

  7. Development of nuclear fuel microsphere handling techniques and equipment

    International Nuclear Information System (INIS)

    Mack, J.E.; Suchomel, R.R.; Angelini, P.

    1979-01-01

    Considerable progress has been made in the development of microsphere handling techniques and equipment for nuclear applications. Work at Oak Ridge National Laboratory with microspherical fuel forms dates back to the early sixties with the development of the sol-gel process. Since that time a number of equipment items and systems specifically related to microsphere handling and characterization have been identified and developed for eventual application in a remote recycle facility. These include positive and negative pressure transfer systems, samplers, weighers, a blender-dispenser, and automated devices for particle size distribution and crushing strength analysis. The current status of these and other components and systems is discussed

  8. Investigation Into Accessible Surface Vinyl Concentrations of Nonstoichiometric PDMS Microspheres from Hydrosilylation Reactions and Their Further Crosslinking Reactions

    DEFF Research Database (Denmark)

    Ma, Baoguang; Hansen, Jens Henrik; Hvilsted, Søren

    2015-01-01

    The introduction of surface vinyl groups to PDMS microspheres broadens the latter's applicability range since the microspheres can be further functionalized or crosslinked into elastomers. Quantification of the surface vinyl concentration of PDMS microspheres is therefore essential. Here, a novel...

  9. Optical diffraction by ordered 2D arrays of silica microspheres

    International Nuclear Information System (INIS)

    Shcherbakov, A.A.; Shavdina, O.; Tishchenko, A.V.; Veillas, C.; Verrier, I.; Dellea, O.; Jourlin, Y.

    2017-01-01

    The article presents experimental and theoretical studies of angular dependent diffraction properties of 2D monolayer arrays of silica microspheres. High-quality large area defect-free monolayers of 1 μm diameter silica microspheres were deposited by the Langmuir-Blodgett technique under an accurate optical control. Measured angular dependencies of zeroth and one of the first order diffraction efficiencies produced by deposited samples were simulated by the rigorous Generalized Source Method taking into account particle size dispersion and lattice nonideality. - Highlights: • High quality silica microsphere monolayer was fabricated. • Accurate measurements of diffraction efficiency angular dependencies. • Rigorous diffraction simulation of both ideal hexagonal and realistic microsphere arrangements. • Qualitative rationalization of the obtained results and the observed differences between the experiment and the theory.

  10. BIOCOMPATIBLE FLUORESCENT MICROSPHERES: SAFE PARTICLES FOR MATERIAL PENETRATION STUDIES

    Energy Technology Data Exchange (ETDEWEB)

    Farquar, G; Leif, R

    2009-07-15

    Biocompatible polymers with hydrolyzable chemical bonds have been used to produce safe, non-toxic fluorescent microspheres for material penetration studies. The selection of polymeric materials depends on both biocompatibility and processability, with tailored fluorescent properties depending on specific applications. Microspheres are composed of USFDA-approved biodegradable polymers and non-toxic fluorophores and are therefore suitable for tests where human exposure is possible. Micropheres were produced which contain unique fluorophores to enable discrimination from background aerosol particles. Characteristics that affect dispersion and adhesion can be modified depending on use. Several different microsphere preparation methods are possible, including the use of a vibrating orifice aerosol generator (VOAG), a Sono-Tek atomizer, an emulsion technique, and inkjet printhead. Applications for the fluorescent microspheres include challenges for biodefense system testing, calibrants for biofluorescence sensors, and particles for air dispersion model validation studies.

  11. Preparation of UN microspheres by internal gelation process

    Energy Technology Data Exchange (ETDEWEB)

    Shirasu, Yoshiro; Yamagishi, Shigeru [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-07-01

    UN microspheres were prepared from (UO{sub 3}+C) microspheres internally gelled in a hot silicone oil column. The gel microspheres were calcined at 480degC in nitrogen, after washing and drying. The calcined ones were carbothermically nitrided at 1400-1800degC in a nitrogen-based atmosphere in two ways: one in N{sub 2} followed by N{sub 2}-8%H{sub 2}, and the other in N{sub 2}-8%H{sub 2} only. In both cases, highly pure UN microspheres around 500 ppm of both oxygen and carbon impurities were obtained, although their densities were still low. (author)

  12. Silicon microspheres for near-IR communication applications

    International Nuclear Information System (INIS)

    Serpengüzel, Ali; Demir, Abdullah

    2008-01-01

    We have performed transverse electric and transverse magnetic polarized elastic light scattering calculations at 90° and 0° in the o-band at 1.3 µm for a 15 µm radius silicon microsphere with a refractive index of 3.5. The quality factors are on the order of 10 7 and the mode/channel spacing is 7 nm, which correlate well with the refractive index and the optical size of the microsphere. The 90° elastic light scattering can be used to monitor a dropped channel (drop port), whereas the 0° elastic scattering can be used to monitor the transmission channel (through port). The optical resonances of the silicon microspheres provide the necessary narrow linewidths that are needed for high-resolution optical communication applications. Potential telecommunication applications include filters, modulators, switches, wavelength converters, detectors, amplifiers and light sources. Silicon microspheres show promise as potential building blocks for silicon-based electrophotonic integration

  13. XPS analysis of aluminosilicate microspheres bioactivity tested in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Todea, M.; Vanea, E. [Faculty of Physics and Institute of Interdisciplinary Research on Bio-Nano-Sciences, Babes Bolyai University, Cluj-Napoca 400084 (Romania); Bran, S. [University of Medicine and Pharmacy “Iuliu Haţieganu”, Department of Cranio-Maxillofacial Surgery, 400029 Cluj-Napoca (Romania); Berce, P. [Technical University of Cluj-Napoca, Faculty of Machine Building and National Centre of Rapid Prototyping, 400641 Cluj-Napoca (Romania); Simon, S., E-mail: simons@phys.ubbcluj.ro [Faculty of Physics and Institute of Interdisciplinary Research on Bio-Nano-Sciences, Babes Bolyai University, Cluj-Napoca 400084 (Romania)

    2013-04-01

    The study aims to characterize surface properties of aluminosilicate microspheres incorporating yttrium, with potential biomedical applications. Micrometric particles of spherical shape were obtained by spray drying method. The behavior of aluminosilicate microspheres without yttrium and with yttrium was investigated under in vitro conditions, by seven days incubation in simulated body fluid (SBF). The surface elemental composition and the atomic environments on outermost layer of the microspheres, prior to and after incubation in SBF were evaluated by X-ray photoelectron spectroscopy (XPS) in order to investigate their bioactivity. The results were analyzed to underline the effect of yttrium addition on surface properties of the aluminosilicate microspheres and implicitly on the behavior of the samples in simulated body environments.

  14. Investigation of defects on PAMS microspheres fabricated with microencapsulation method

    International Nuclear Information System (INIS)

    Chen Sufen; Li Bo; Liu Yiyang; Zhang Zhanwen; Qi Xiaobo

    2012-01-01

    Poly-(α-methylstyrene) (PAMS) microspheres were fabricated with W1/O/W2 double emulsion microencapsulation method, and the effects of polyvinylalcohol (PVA) and CaCl 2 weight concentrations and the O/W2 phase ratio on the percentages of defected PAMS microspheres were studied. The weight concentrations of PVA and CaCl 2 and the O/W2 phase ratio in the fabrication process of PAMS microspheres were optimized. The results show that, for the three parameters being 1.0%, 1.5%, and 0.01, respectively, the percentage of the defect-free PAMS microspheres without vacuoles in the shell wall can be up to 60%. (authors)

  15. Preparation and In-vitro Evaluation of Metformin Microspheres Using ...

    African Journals Online (AJOL)

    . Methods: Metformin microspheres were prepared by non-aqueous solvent evaporation method using various polymers, including ethylcellulose (EC), hydroxypropyl methylcellulose (HPMC), carbopol 934P (CA) and chitosan (CH). The effect ...

  16. Investigation of concrete mixtures incorporating hollow plastic microspheres.

    Science.gov (United States)

    1981-01-01

    This study investigated the potential of hollow plastic microspheres, HPM, for providing non-air-entrained portland cement concrete resistance to damage from cycles of freezing and thawing. In the study, a mixture with an air-entraining agent (vinsol...

  17. Resonant microsphere gyroscope based on a double Faraday rotator system.

    Science.gov (United States)

    Xie, Chengfeng; Tang, Jun; Cui, Danfeng; Wu, Dajin; Zhang, Chengfei; Li, Chunming; Zhen, Yongqiu; Xue, Chenyang; Liu, Jun

    2016-10-15

    The resonant microsphere gyroscope is proposed based on a double Faraday rotator system for the resonant microsphere gyroscope (RMSG) that is characterized by low insertion losses and does not destroy the reciprocity of the gyroscope system. Use of the echo suppression structure and the orthogonal polarization method can effectively inhibit both the backscattering noise and the polarization error, and reduce them below the system sensitivity limit. The resonance asymmetry rate dropped from 34.2% to 2.9% after optimization of the backscattering noise and the polarization noise, which greatly improved the bias stability and the scale factor linearity of the proposed system. Additionally, based on the optimum parameters for the double Faraday rotator system, a bias stability of 0.04°/s has been established for an integration time of 10 s in 1000 s in a resonator microsphere gyroscope using a microsphere resonator with a diameter of 1 mm and a Q of 7.2×106.

  18. Facile preparation of hierarchically porous polymer microspheres for superhydrophobic coating

    Science.gov (United States)

    Gao, Jiefeng; Wong, Julia Shuk-Ping; Hu, Mingjun; Li, Wan; Li, Robert. K. Y.

    2013-12-01

    A facile method, i.e., nonsolvent assisted electrospraying, is proposed to fabricate hierarchically porous microspheres. The pore size on the microsphere surface ranges from a few tens to several hundred nanometers. Thermally and nonsolvent induced phase separation as well as breath figure is responsible for the formation of the hierarchical structures with different nano-sized pores. The nonsolvent could not only induce phase separation, but also stabilize the interface between the droplet and air, which can prevent the droplet from strong deformation, and is therefore beneficial to the formation of regular and uniform microspheres. On the other hand, solvent evaporation, polymer diffusion and Coulomb fission during electrospraying influence the morphology of finally obtained products. In this paper, the influence of polymer concentration, the weight ratio between nonsolvent and polymer and the flowing rate on the morphology of the porous microsphere is carefully studied. The hierarchically porous microsphere significantly increases the surface roughness and thus the hydrophobicity, and the contact angle can reach as high as 152.2 +/- 1.2°. This nonsolvent assisted electrospraying opens a new way to fabricate superhydrophobic coating materials.A facile method, i.e., nonsolvent assisted electrospraying, is proposed to fabricate hierarchically porous microspheres. The pore size on the microsphere surface ranges from a few tens to several hundred nanometers. Thermally and nonsolvent induced phase separation as well as breath figure is responsible for the formation of the hierarchical structures with different nano-sized pores. The nonsolvent could not only induce phase separation, but also stabilize the interface between the droplet and air, which can prevent the droplet from strong deformation, and is therefore beneficial to the formation of regular and uniform microspheres. On the other hand, solvent evaporation, polymer diffusion and Coulomb fission during

  19. [Optimization of riboflavin sodium phosphate loading to calcium alginate floating microspheres by response surface methodology].

    Science.gov (United States)

    Zhang, An-yang; Fan, Tian-yuan

    2009-12-18

    To investigate the preparation, optimization and in vitro properties of riboflavin sodium phosphate floating microspheres. The floating microspheres composed of riboflavin sodium phosphate and calcium alginate were prepared using ion gelatin-oven drying method. The properties of the microspheres were investigated, including the buoyancy, release, appearance and entrapment efficiency. The formulation was optimized by response surface methodology (RSM). The optimized microspheres were round. The entrapment efficiency was 57.49%. All the microspheres could float on the artificial gastric juice over 8 hours. The release of the drug from the microspheres complied with Fick's diffusion.

  20. A review on target drug delivery: magnetic microspheres

    OpenAIRE

    Amit Chandna; Deepa Batra; Satinder Kakar; Ramandeep Singh

    2013-01-01

    Novel drug delivery system aims to deliver the drug at a rate directed by the needs of the body during the period of treatment, and target the active entity to the site of action. A number of novel drug delivery systems have emerged encompassing various routes of administration, to achieve controlled and targeted drug delivery, magnetic micro carriers being one of them. Magnetic microsphere is newer approach in pharmaceutical field. Magnetic microspheres as an alternative to traditional ra...

  1. Preoperative fasting time in children.

    LENUS (Irish Health Repository)

    Adeel, S

    2012-02-01

    The aim of preoperative fasting is to prevent regurgitation and pulmonary aspiration while limiting potential problems of thirst, dehydration and hypoglycaemia. The American Society of Anaesthesiologists (ASA) has suggested guidelines for preoperative fasting for children undergoing elective surgery. We did a postal survey to determine the current practice regarding these guidelines amongst all specialist registrars in anaesthesia in Ireland. A questionnaire was sent to all specialist registrars in anaesthesia (90 in total), 60 (67%) were returned and analysed. The question asked was how long children should be kept fasting before elective surgery. The results of our survey suggest that most of the respondents are following the ASA guidelines for clear fluids and solids however there were differing opinion regarding the duration of fasting for formula milk and breast milk. In conclusion, we would recommend greater awareness and collaboration between anaesthetists, nurses and surgeons to ensure that fasting instructions are consistent with the ASA guidelines and that patient and their parents understand these directives as well.

  2. Preoperative irradiation of hypernephroid carcinoma

    International Nuclear Information System (INIS)

    Akbar, D.

    1982-01-01

    Since 1969, preoperative irradiation of hypernephiroid carcinoma has been a routine measure at the Steglitz medical clinic: It consists in the application of a focal dose of 30 Gy, fractionated into doses of 2.5 Gy, as Betatron pendulum irradiation (42 MeV photons) covering the para-aortic lymph nodes. After a treatment-free interval of 3 weeks, radical nephrectomy is carried through. Of 178 patients, 47 were in tumor stage I, 15 in stage II, 83 in stage III and 33 in stage IV. In 99 patients the treatment dated back longer than 5 years; the survival rate was 52%. 67% of the patients had survived longer than 3 years. Operation lethality was 3%. The preoperative irradiation pursues the following aims: 1. Devitalization of potentially proliferating cells in the tumor periphery, and thus prevention of displaced tumor cells growing on and postoperative local recidivations; 2. Shrinking of the tumor, facilitating the surgical intervention. In a third of the cases a measurable alteration of the tumor was confirmed by X-ray. The low operation lethality of 3% is attributed to this. (orig./MG) [de

  3. Preoperative embolization of gigantic meningioma

    International Nuclear Information System (INIS)

    Wang Hongsheng; Chen Huaqun; Dong Congsong; Li Wenhui; Dai Zhenyu; Chen Guozhi

    2006-01-01

    Objective: To evaluate the clinical efficacy of preoperative embolization in treatment of patients with gigantic meningioma. Methods: Fourteen cases of gigantic meningioma diameter from 6 to 11 cm were measured by CT and MRI scan. DSA manifested that they are vascularizd meningioma and showed the mainly feeding arteries. We used getation sponge to superselectively embilized the feeding arteries. All tumors were performed surgical excision 3-7 days after the embolization. Results: DSA showed the blood supplies in the tumors in 9 cases were completely blocked, and that in 5 cases were dramatically eliminated. All patients were operated 3-7 days after the embolization. During the operations the bleeding were dramatically decreased and the operation time was shortened compared with those in unembolized cases. It helps us remove the tumors easy and quickly from the attachments. No complication occurred during and after the operations. Conclusion: Preoperative embolization of gigantic meningioma is a useful and relatively safe method in helping surgicaly and completely excised of tumor with significant reduction of blood loss and operation time. (authors)

  4. Preoperative embolization of facial angiomas

    International Nuclear Information System (INIS)

    Causmano, F.; Bruschi, G.; De Donatis, M.; Piazza, P.; Bassi, P.

    1988-01-01

    Preoperative embolization was performed on 27 patients with facial angiomas supplied by the external carotid branches. Sixteen were males and 11 females; 13 of these angiomas were high-flow arterio-venous (A-V), 14 were low-flow capillary malformations. Fourteen patients underwent surgical removal after preoperative embolization; in this group embolization was carried out with Spongel in 3 cases and with Lyodura in 11 cases. In 12 of these patients the last angiographic examination was performed 3-6 years later: angiography evidenced no recurrence in 8 cases (67%), while in 3 cases (25%) there was capillary residual angioma of negligible size. Treatment was unsuccessful in one patient only, due to the large recurrent A-V angioma. Thirteen patients underwent embolization only, which was carried out with Lyodura in 10 cases, and with Ivalon in 3 cases. On 12 of these patients the last angiographic study was performed 2-14 months later: there was recurrent A-V angioma in 5 patients (42%), who underwent a subsequent embolization; angiography evidenced no recurrence in the other 7 patients (58%). In both series, the best results were obtained in the patients with low-flow capillary angiomas. Embolization and subsequent surgical removal are the treatment of choice for facial angiomas; embolization alone is useful in the management of surgically inacessible vascular malformations, and it can be the only treatment in patients with small low-flow angiomas when distal occlusion of the feeding vessel with Lyodura or Ivalon particles is performed

  5. Development and Evaluation of Isoniazid Loaded Silk Fibroin Microsphere

    Directory of Open Access Journals (Sweden)

    Narinder Singh

    Full Text Available Aim: Current experimental investigation is dedicated to prepare microspheres with small size and good sphericity by Phase Separation method using Isoniazid (INH as model drug. Silk fibroin has unique intrinsic qualities like biodegradability, biocompatibility or release properties and their tunable drug loading capacity. The delivery loading proficiency of the drug molecules in silk spheres be contingent on their charge, and hydrophobicity or subsequent in altered drug release profiles. Methods: In the present work Isoniazid loaded silk fibroin microsphere was prepared by using phase separation method. Microsphere was evaluated for Ultraviolet-visible spectroscopy, Fourier Transform infrared spectroscopy, Entrapment efficiency, Scanning electron microscopy Studies. Results: Scanning electron microscopy studies revealed that Isoniazid Loaded Silk Fibroin Microspheres were spherical. Entrapment Efficiency of Isoniazid loaded Microspheres of different Formulation from F1 to F5 was in range of 53 to 68 %. F3 showed 68.47 % entrapment Efficiency and the optimized formulation drug release was 93.56 % at 24 hours. Conclusion: Experimental report disclosed a new aqueous based formulation method for silk spheres with controllable shape or size and sphere. Isoniazid loaded silk microspheres may act as ideal nano formulation with elaborated studies.

  6. Synthesis and characterization of Supeparamagnetics Microspheres (PMMA via suspension polymerization

    Directory of Open Access Journals (Sweden)

    Paulo Emilio Feuser

    2014-02-01

    Full Text Available Magnetics nanoparticles (NPMs has found many applications in biomedical and technological areas. The objective of this work is the preparation and characterization of PMMA microspheres containing NPMs coated with oleic acid (NPMs-AO. For the preparation of MNPs-AO was used the coprecipitation method in an aqueous medium. For the preparation of the superparamagnetic microspheres used in suspension polymerization technique. The microspheres showed a size distribution particles of approximately 150um and a spherical morphology. From the analysis of gel permeation chromatography (GPC determined the number average molecular weight (Mw of the magnetics microspheres and there was a variation in the Mw depending on the concentration of MNPs-AO in this reaction. To analyze the magnetic properties used the vibrating sample magnetometer (MAV. The microspheres showed superparamagnetic properties and a value of saturation magnetization (Ms of about 8 emu/g MNPs. Therefore you can conclude that it is possible to obtain superparamagnetics microspheres for a particular application, either, biomedical or technological.

  7. Innovative hydrogen storage in hollow glass-microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Keding, M.; Schmid, G.; Tajmar, M. [Austrian Research Centers, Vienna (Austria)

    2009-07-01

    Hydrogen storage technologies are becoming increasingly important for a number of future applications. The Austrian Research Centers (ARC) are developing a unique hydrogen storage system that combines the advantages of both hollow glass microsphere and chemical compound hydrogen storage, but eliminates their respective drawbacks. Water is utilized as a functional liquid to carry the hollow glass microspheres that are loaded with up to 700 bar of hydrogen gas. Sodium borohydride (NaBH{sub 4}) is then injected together with the glass microspheres into a reaction chamber where the water reacts catalytically with the NaBH{sub 4} producing hydrogen and heat. The heat is then utilized to release the hydrogen from the hollow glass microspheres providing a double hydrogen generation process without any external energy or heat during storage or gas release. The paper described this hydrogen storage system with particular reference to microspheres, the coating process, the experimental facility and NaBH{sub 4} test results. It was concluded that hydrogen storage and production on demand is possible with microspheres and sodium borohydride solution. 9 refs., 16 figs.

  8. Microspheres and Nanotechnology for Drug Delivery.

    Science.gov (United States)

    Jóhannesson, Gauti; Stefánsson, Einar; Loftsson, Thorsteinn

    2016-01-01

    Ocular drug delivery to the posterior segment of the eye can be accomplished by invasive drug injections into different tissues of the eye and noninvasive topical treatment. Invasive treatment involves the risks of surgical trauma and infection, and conventional topical treatments are ineffective in delivering drugs to the posterior segment of the eye. In recent years, nanotechnology has become an ever-increasing part of ocular drug delivery. In the following, we briefly review microspheres and nanotechnology for drug delivery to the eye, including different forms of nanotechnology such as nanoparticles, microparticles, liposomes, microemulsions and micromachines. The permeation barriers and anatomical considerations linked to ocular drug delivery are discussed and a theoretical overview on drug delivery through biological membranes is given. Finally, in vitro, in vivo and human studies of x03B3;-cyclodextrin nanoparticle eyedrop suspensions are discussed as an example of nanotechnology used for drug delivery to the eye. © 2016 S. Karger AG, Basel.

  9. Chitosan microspheres in novel drug delivery systems.

    Science.gov (United States)

    Mitra, Analava; Dey, Baishakhi

    2011-07-01

    The main aim in the drug therapy of any disease is to attain the desired therapeutic concentration of the drug in plasma or at the site of action and maintain it for the entire duration of treatment. A drug on being used in conventional dosage forms leads to unavoidable fluctuations in the drug concentration leading to under medication or overmedication and increased frequency of dose administration as well as poor patient compliance. To minimize drug degradation and loss, to prevent harmful side effects and to increase drug bioavailability various drug delivery and drug targeting systems are currently under development. Handling the treatment of severe disease conditions has necessitated the development of innovative ideas to modify drug delivery techniques. Drug targeting means delivery of the drug-loaded system to the site of interest. Drug carrier systems include polymers, micelles, microcapsules, liposomes and lipoproteins to name some. Different polymer carriers exert different effects on drug delivery. Synthetic polymers are usually non-biocompatible, non-biodegradable and expensive. Natural polymers such as chitin and chitosan are devoid of such problems. Chitosan comes from the deacetylation of chitin, a natural biopolymer originating from crustacean shells. Chitosan is a biocompatible, biodegradable, and nontoxic natural polymer with excellent film-forming ability. Being of cationic character, chitosan is able to react with polyanions giving rise to polyelectrolyte complexes. Hence chitosan has become a promising natural polymer for the preparation of microspheres/nanospheres and microcapsules. The techniques employed to microencapsulate with chitosan include ionotropic gelation, spray drying, emulsion phase separation, simple and complex coacervation. This review focuses on the preparation, characterization of chitosan microspheres and their role in novel drug delivery systems.

  10. Preoperative patient education: evaluating postoperative patient outcomes.

    Science.gov (United States)

    Meeker, B J

    1994-04-01

    Preoperative teaching is an important part of patient care and can prevent complications, as well as promote patient fulfillment during hospitalization. A study was conducted at Alton Ochsner Medical Foundation in New Orleans, LA, in 1989, to determine the impact of a preoperative teaching program on the incidence of postoperative atelectasis and patient satisfaction. Results showed no significant difference of postoperative complications and patient gratification after participating in a structured preoperative teaching program. As part of this study, it was identified that a patient evaluation tool for a preoperative teaching class needed to be developed. The phases of this process are explained in the following article.

  11. Interventions for preoperative smoking cessation

    DEFF Research Database (Denmark)

    Thomsen, Thordis; Villebro, Nete; Møller, Ann Merete

    2010-01-01

    a smoking cessation intervention, and measured preoperative and long-term abstinence from smoking and/or the incidence of postoperative complications. Data collection and analysis The authors independently assessed studies to determine eligibility. Results were discussed between the authors. Main results...... Eight trials enrolling a total of 1156 people met the inclusion criteria. One of these did not report cessation as an outcome. Two trials initiated multisession face to face counselling at least 6 weeks before surgery whilst six used a brief intervention. Nicotine replacement therapy (NRT) was offered......; pooled RR 10.76 (95% confidence interval (CI) 4.55 to 25.46, two trials) and RR 1.41 (95% CI 1.22 to 1.63, five trials) respectively. Four trials evaluating the effect on long-term smoking cessation found a significant effect; pooled RR 1.61 (95% CI 1.12 to 2.33). However, when pooling intensive...

  12. Renal toxicity of 2 cycles of peptide receptor radionuclide therapy as determined by serial measurements of the Glomerular Filtration Rate (GFR): comparison between Y-90 DOTA-TATE and Lu-177 DOTA-TATE

    International Nuclear Information System (INIS)

    Baum, R.P.; Prasad, V.

    2007-01-01

    Full text: Aim: To determine the effect of peptide receptor radionuclide therapy on GFR after 2 cycles of Y-90-DTATATE as compared to Lu-177-DOTA-TATE. Methods: Group A (Y-90), Group B (Lu-177). Group A1: 24 pts (age 60.5±11a), injected with 4.00± 0.72 GBq of Y-90 (1st cycle). Group A2: 16 pts (age 62.2±9.4a, followed up after 7.8 GBq±0.82 GBq of Y-90 (after 2nd cycle). Group B1: 14 pts (age 62.2±10.6a) 4.8± 0.8 GBq Lu-177 (1st cycle). Group B2: 6 patients (age 58.5±12a) after 9.57±1.5 GBq of Lu-177 (after 2nd cycle). GFR was determined using 110- 185 MBq of Tc-99m DTPA before and 3-4 months after therapy. Absolute/normalized values for GFR pre/post PRRT were compared (paired T-test).The effect of total amount of radioactivity administered, pre-existing diabetes, hypertension and age on renal function post 2 cycles of PRRT were also evaluated. Results: In group A1 normalized GFR dropped by 2% (absol. GFR fall: 2 ml/min) as compared to 16% in group A2 (absol. GFR fall: 7 ml/min). Baseline normalized/absol. GFR values were 1.02/87.5 ml/min in subgroup A1 and 1.02 / 86.5 ml/min in A2. The fall in both, the absolute and normalized GFR values was not significant after the 1st cycle (p=0.555), but was significant (p= 0.007) after the 2nd PRRT. In group B1 there was a fall of normalized GFR value by 10% vs. 8% in group B2. The fall in absol. GFR value was 7.7 ml/min in group B1 and 9.7 ml/min in group B2. Baseline normalized GFR values was 0.86 and 0.89 in subgroups B1 and B2, respectively. Baseline absol. GFR value was 78.3 ml/min and 81 ml/min in subgroups B1 and B2. The fall in the absol. GFR values was significant after the 1st cycle (p=.009), but was not significant (p=0.486) after the 2nd cycle of PRRT. The fall in normalized GFR value was not significant in both subgroups (p=0.07 after 1st cycle and p=0.49 after 2nd cycle). No correlation between the activity administered and the percentage change in the GFR values in both the groups (Pearson's correlation

  13. The synthesis and photocatalytic activity of ZnSe microspheres

    International Nuclear Information System (INIS)

    Cao Huaqiang; Xiao Yujiang; Zhang Sichun

    2011-01-01

    This paper reports the synthesis of semiconductor ZnSe microspheres composed of nanoparticles via a solvothermal route between the organic molecule selenophene (C 4 H 4 Se) and ZnCl 2 without adding any surfactant. The ZnSe microspheres were characterized by x-ray diffraction (XRD), Raman spectroscopy, scanning electron microscopy (SEM), field emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM), high resolution transmission electron microscopy (HRTEM), specific surface area measurement, and photoluminescence (PL) spectra. A strong and broad blue PL emission at 443 nm in wavelength (∼2.79 eV in photon energy) is attributed to the near-band-edge (NBE) emission of ZnSe, while the 530 nm peak is a defect-related (DL) emission. The photocatalytic activity of the as-prepared ZnSe microspheres was evaluated by photodegradation of methyl orange (MO) dye under ultraviolet (UV) light and visible light irradiation. The degradations of MO reach 94% or 95.1%, close to 100%, in the presence of the as-synthesized ZnSe microspheres or commercial ZnSe powder after 7 or 10 h under UV irradiation, respectively. Meanwhile the degradations of MO reach 94.3% or 60.6% in the presence of the as-synthesized ZnSe microspheres or commercial ZnSe powder after 12 h, respectively. The degradation rate of ZnSe microspheres is twice that of ZnSe commercial powder under UV light irradiation, and three times under visible light irradiation. The degradation process of MO dye on ZnSe microspheres under UV or visible light is also discussed.

  14. Microsphere-based super-resolution scanning optical microscope.

    Science.gov (United States)

    Huszka, Gergely; Yang, Hui; Gijs, Martin A M

    2017-06-26

    High-refractive index dielectric microspheres positioned within the field of view of a microscope objective in a dielectric medium can focus the light into a so-called photonic nanojet. A sample placed in such nanojet can be imaged by the objective with super-resolution, i.e. with a resolution beyond the classical diffraction limit. However, when imaging nanostructures on a substrate, the propagation distance of a light wave in the dielectric medium in between the substrate and the microsphere must be small enough to reveal the sample's nanometric features. Therefore, only the central part of an image obtained through a microsphere shows super-resolution details, which are typically ∼100 nm using white light (peak at λ = 600 nm). We have performed finite element simulations of the role of this critical distance in the super-resolution effect. Super-resolution imaging of a sample placed beneath the microsphere is only possible within a very restricted central area of ∼10 μm 2 , where the separation distance between the substrate and the microsphere surface is very small (∼1 μm). To generate super-resolution images over larger areas of the sample, we have fixed a microsphere on a frame attached to the microscope objective, which is automatically scanned over the sample in a step-by-step fashion. This generates a set of image tiles, which are subsequently stitched into a single super-resolution image (with resolution of λ/4-λ/5) of a sample area of up to ∼10 4 μm 2 . Scanning a standard optical microscope objective with microsphere therefore enables super-resolution microscopy over the complete field-of-view of the objective.

  15. Preparation of open porous polycaprolactone microspheres and their applications as effective cell carriers in hydrogel system

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Qingchun [Key Laboratory for Ultrafine Materials of Ministry of Education, School of Materials Science and Engineering (China); Tan, Ke; Ye, Zhaoyang [State Key Laboratory of Bioreactor Engineering, School of Bioengineering, East China University of Science and Technology, Shanghai, 200237 China (China); Zhang, Yan, E-mail: zhang_yan@ecust.edu.cn [Key Laboratory for Ultrafine Materials of Ministry of Education, School of Materials Science and Engineering (China); Tan, Wensong [State Key Laboratory of Bioreactor Engineering, School of Bioengineering, East China University of Science and Technology, Shanghai, 200237 China (China); Lang, Meidong, E-mail: mdlang@ecust.edu.cn [Key Laboratory for Ultrafine Materials of Ministry of Education, School of Materials Science and Engineering (China)

    2012-12-01

    Common hydrogel, composed of synthetic polymers or natural polysaccharides could not support the adhesion of anchorage-dependent cells due to the lack of cell affinitive interface and high cell constraint. The use of porous polyester microspheres as cell-carriers and introduction of cell-loaded microspheres into the hydrogel system might overcome the problem. However, the preparation of the open porous microsphere especially using polycaprolactone (PCL) has been rarely reported. Here, the open porous PCL microspheres were fabricated via the combined emulsion/solvent evaporation and particle leaching method. The microspheres exhibited porous surface and inter-connective pore structure. Additionally, the pore structure could be easily controlled by adjusting the processing parameters. The surface pore size could be altered from 20 {mu}m to 80 {mu}m and the internal porosities were varied from 30% to 70%. The obtained microspheres were evaluated to delivery mesenchymal stem cells (MSCs) and showed the improved cell adhesion and growth when compared with the non-porous microspheres. Then, the MSCs loaded microspheres were introduced into agarose hydrogel. MSCs remained alive and sustained proliferation in microsphere/agarose composite in 5-day incubation while a decrement of MSCs viabilities was found in agarose hydrogel without microspheres. The results indicated that the microsphere/hydrogel composite had a great potential in cell therapy and injectable system for tissue regeneration. Highlights: Black-Right-Pointing-Pointer The open porous polycaprolactone microspheres were fabricated using paraffin as a porogen. Black-Right-Pointing-Pointer The microspheres exhibited porous surface and inter-connective pore structure. Black-Right-Pointing-Pointer The surface and internal pore size and porosity of microsphere could be controlled. Black-Right-Pointing-Pointer The porous microspheres exhibited an improved cell adhesion and proliferation. Black

  16. Impaired anastomotic healing after preoperative radiotherapy ...

    African Journals Online (AJOL)

    Background. Patients with rectal carcinoma undergoing total mesorectal excision (TME) have a lower recurrence rate with preoperative radiotherapy (RT). The aim of this study was to assess the side-effects in patients who had preoperative RT compared with those who did not receive it (because of palliative resections, ...

  17. Preoperative Smoking Status and Postoperative Complications

    DEFF Research Database (Denmark)

    Pedersen, Marie Grønkjær; Eliasen, Marie; Skov-Ettrup, Lise Skrubbeltrang

    2014-01-01

    To systematically review and summarize the evidence of an association between preoperative smoking status and postoperative complications elaborated on complication type.......To systematically review and summarize the evidence of an association between preoperative smoking status and postoperative complications elaborated on complication type....

  18. Preoperative breast radiation therapy: Indications and perspectives

    DEFF Research Database (Denmark)

    Lightowlers, S V; Boersma, L J; Fourquet, A

    2017-01-01

    Preoperative breast radiation therapy (RT) is not a new concept, but older studies failed to change practice. More recently, there has been interest in revisiting preoperative RT using modern techniques. This current perspective discusses the indications, summarises the published literature and t...

  19. Ulex europaeus 1 lectin targets microspheres to mouse Peyer's patch M-cells in vivo.

    Science.gov (United States)

    Foster, N; Clark, M A; Jepson, M A; Hirst, B H

    1998-03-01

    The interaction of latex microspheres with mouse Peyer's patch membranous M-cells was studied in a mouse gut loop model after the microspheres were coated with a variety of agents. Carboxylated microspheres (diameter 0.5 micron) were covalently coated with lectins Ulex europaeus 1, Concanavalin A, Euonymus europaeus and Bandeiraea simplicifolia 1 isolectin-B4, human immunoglobulin A or bovine serum albumin. Of the treatments examined, only Ulex europaeus (UEA1) resulted in significant selective binding of microspheres to M-cells. UEA1-coated microspheres bound to M-cells at a level 100-fold greater than BSA-coated microspheres, but binding to enterocytes was unaffected. Incubation of UEA1-coated microspheres with alpha-L-fucose reduced M-cell binding to a level comparable with BSA-coated microspheres. This indicated that targeting by UEA1 was via a carbohydrate receptor on the M-cell surface. Adherence of UEA1-coated microspheres to M-cells occurred within 10 min of inoculation into mouse gut loops and UEA1-coated microspheres were transported to 10 microns below the apical surface of M-cells within 60 min of inoculation. UEA1-coated microspheres also targeted mouse Peyer's patch M-cells after intragastric administration. These results demonstrated that altering the surface chemistry of carboxylated polystyrene microspheres increased M-cell targeting, suggesting a strategy to enhance delivery of vaccine antigens to the mucosal immune system.

  20. A reproducible accelerated in vitro release testing method for PLGA microspheres.

    Science.gov (United States)

    Shen, Jie; Lee, Kyulim; Choi, Stephanie; Qu, Wen; Wang, Yan; Burgess, Diane J

    2016-02-10

    The objective of the present study was to develop a discriminatory and reproducible accelerated in vitro release method for long-acting PLGA microspheres with inner structure/porosity differences. Risperidone was chosen as a model drug. Qualitatively and quantitatively equivalent PLGA microspheres with different inner structure/porosity were obtained using different manufacturing processes. Physicochemical properties as well as degradation profiles of the prepared microspheres were investigated. Furthermore, in vitro release testing of the prepared risperidone microspheres was performed using the most common in vitro release methods (i.e., sample-and-separate and flow through) for this type of product. The obtained compositionally equivalent risperidone microspheres had similar drug loading but different inner structure/porosity. When microsphere particle size appeared similar, porous risperidone microspheres showed faster microsphere degradation and drug release compared with less porous microspheres. Both in vitro release methods investigated were able to differentiate risperidone microsphere formulations with differences in porosity under real-time (37 °C) and accelerated (45 °C) testing conditions. Notably, only the accelerated USP apparatus 4 method showed good reproducibility for highly porous risperidone microspheres. These results indicated that the accelerated USP apparatus 4 method is an appropriate fast quality control tool for long-acting PLGA microspheres (even with porous structures). Copyright © 2015 Elsevier B.V. All rights reserved.

  1. A review on target drug delivery: magnetic microspheres

    Directory of Open Access Journals (Sweden)

    Amit Chandna

    2013-01-01

    Magnetic microsphere is newer approach in pharmaceutical field. Magnetic microspheres as an alternative to traditional radiation methods which use highly penetrating radiation that is absorbed throughout the body. Its use is limited by toxicity and side effects. The aim of the specific targeting is to enhance the efficiency of drug delivery & at the same time to reduce the toxicity & side effects. This kind of delivery system is very much important which localises the drug to the disease site. In this larger amount of freely circulating drug can be replaced by smaller amount of magnetically targeted drug. Magnetic carriers receive magnetic responses to a magnetic field from incorporated materials that are used for magnetic microspheres are chitosan, dextran etc. magnetic microspheres can be prepared from a variety of carrier material. One of the most utilized is serum albumin from human or other appropriate species. Drug release from albumin microspheres can be sustained or controlled by various stabilization procedures generally involving heat or chemical cross-linking of the protein carrier matrix.

  2. Magnetic propulsion of microspheres at liquid-glass interfaces

    Science.gov (United States)

    Helgesen, Geir

    2018-02-01

    Bio-coated, magnetic microspheres have many applications in biotechnology and medical technology as a tool to separate and extract cells or molecules in a water solution by applying external strong magnetic field gradients. However, magnetic microspheres with or without attached cargo can also be separated in the liquid solution if they are exposed to alternating or rotating, relatively weak magnetic fields. Microspheres that have a higher density than the liquid will approach the bottom surface of the sample cell, and then a combination of viscous and surface frictional forces can propel the magnetic microspheres along the surface in a direction perpendicular to the axis of field rotation. Experiments demonstrating this type of magnetic propulsion are shown, and the forces active in the process are discussed. The motion of particles inside sample cells that were tilted relative to the horizontal direction was studied, and the variation of propulsion velocity as a function of tilt angle was used to find the values of different viscous and mechanical parameters of motion. Propulsion speeds of up to 5 μm/s were observed and were found to be caused by a partly rolling and partly slipping motion of rotating microspheres with a slipping coefficient near 0.6.

  3. Pharmacodynamics of diclofenac from novel Eudragit entrapped microspheres.

    Science.gov (United States)

    Momoh, M A; Kenechukwu, F C; Adedokun, M O; Odo, C E; Attama, A A

    2014-05-01

    Effective clinical utilization of non-steroidal anti-inflammatory drugs such as diclofenac sodium (DS) is significantly limited by their ulcerogenic potential and poor bioavailability after oral administration, thus necessitating the need for a better carrier to minimize these obvious limitations. The objective of this study was to evaluate Eudragit® RS100/RL100 microspheres formulated by the solvent-evaporation technique for improved delivery of diclofenac. Three batches of (DF1, DF2 and DF3) microspheres were prepared using different ratios of Eudragit RS-100 and RL-100 polymers based on the solvent-evaporation method. The microspheres were characterized based on morphological properties, particle size analysis and encapsulation efficiency (EE%). In vitro release of DS was investigated in both 0.1 N HCl (pH 1.2) and phosphate-buffered saline (pH 7.4), while anti-inflammatory studies were evaluated in the rat model. Maximum EE% of 86.61 ± 0.11, 88.14 ± 0.16 and 85.50 ± 0.21 was obtained for DF1, DF2 and DF3, respectively. Discrete, smooth and brownish microspheres of size range 437 ± 0.01-479 ± 0.21 µm were obtained. Release of DS from the formulation depends on the polymer ratio. All the batches exhibited good anti-inflammatory activities. Microsphere formulations based on Eudragit® polymers would likely offer a reliable and alternative means of delivering DS orally.

  4. Iron Nanoparticles-Encapsulating Silica Microspheres for Arterial Embolization Hyperthermia

    Energy Technology Data Exchange (ETDEWEB)

    Li, Z; Kawashita, M, E-mail: zhixia@ecei.tohoku.ac.jp [Graduate School of Biomedical Engineering, Tohoku University (Japan)

    2011-10-29

    We attempted to prepare {alpha}-Fe-encapsulating silica ({alpha}FeSi) microspheres by a sol-gel process using tetramethoxysilane (TMOS) in water-in-oil emulsion. The effect of preparation conditions on the structure, magnetic and heating properties of resultant products were investigated. Oil phase consisted of kerosene with 32 wt% of surfactants (sorbitan monooleate / sorbitan monostearate in 3:1 weight ratio). Water phase consisted of TMOS, ethanol (CH{sub 2}CH{sub 3}OH), water and iron nitrate (Fe(NO{sub 3}){sub 3{center_dot}}9H{sub 2}O) with TMOS / CH{sub 2}CH{sub 3}OH/H{sub 2}O/Fe{sup 3+} in 1:7.4:16.2:0.4{approx}1.2 molar ratio. Fe{sup 3+}-containing silica gel (FeSiG) microspheres 5 to 30 {mu}m in size were successfully obtained by adding the water phase into the oil phase at 60 deg. C under stirring of 1500 rpm for 100 min. {alpha}FeSi microspheres was obtained by heating the FeSiG microspheres at 850deg. C in argon atmosphere. The obtained {alpha}FeSi microspheres have a saturation magnetization (Ms) up to 21 emu g{sup -1} and a coercive force (Hc) of 133 Oe. The in vitro heating generation was evaluated under an alternating current (AC) magnetic field of 300 Oe and 100 kHz.

  5. Solvent/Non-Solvent Sintering To Make Microsphere Scaffolds

    Science.gov (United States)

    Laurencin, Cato T.; Brown, Justin L.; Nair, Lakshmi

    2011-01-01

    A solvent/non-solvent sintering technique has been devised for joining polymeric microspheres to make porous matrices for use as drug-delivery devices or scaffolds that could be seeded with cells for growing tissues. Unlike traditional sintering at elevated temperature and pressure, this technique is practiced at room temperature and pressure and, therefore, does not cause thermal degradation of any drug, protein, or other biochemical with which the microspheres might be loaded to impart properties desired in a specific application. Also, properties of scaffolds made by this technique are more reproducible than are properties of comparable scaffolds made by traditional sintering. The technique involves the use of two miscible organic liquids: one that is and one that is not a solvent for the affected polymer. The polymeric microspheres are placed in a mold having the size and shape of the desired scaffold, then the solvent/non-solvent mixture is poured into the mold to fill the void volume between the microspheres, then the liquid mixture is allowed to evaporate. Some of the properties of the resulting scaffold can be tailored through choice of the proportions of the liquids and the diameter of the microspheres.

  6. Research progress of fabricating polyvinyl alcohol coating on plastic microsphere

    International Nuclear Information System (INIS)

    Su Lin; Chen Sufen; Liu Meifang; Zhang Zhanwen; Yao Hong; Li Bo; Liu Yiyang

    2012-01-01

    In the procedures of designing polystyrene-polyvinyl alcohol-CH (carbon and hydrogen elements) (PS-PVA-CH) triple-layer microspheres, there are many methods such as drop-tower technique, emulsion micro-encapsulation, dip (spin) coating, interfacial polycondensation, and spraying technique to prepare the PVA coating. Drop-tower technique, emulsion micro-encapsulation and dip (spin) coating are most-commonly used. The advantages, disadvantages and the research progress of the three methods are summarized in this paper. Emulsion micro-encapsulation is suitable for preparing double-layer microspheres of sizes smaller then 500 μm, with high survival ratio and good quality. However, the preparation process is easily influenced by artificial factors. Small-sized double-layer microspheres can also be prepared by the drop-tower technique, and the preparation period is short. But there are still some problems such as the difficulty in designing the droplet generator, uneven PVA coating and the difficulty in preparing large-sized microspheres. Dip (spin) coating technique can be used to prepare PS-PVA microspheres with sizes larger than 1000 μm, but the spread of PVA coating is affected by many factors in this method, and the prepared PVA coating is too thin and not uniform. (authors)

  7. IVIVC from Long Acting Olanzapine Microspheres

    Directory of Open Access Journals (Sweden)

    Susan D'Souza

    2014-01-01

    Full Text Available In this study, four PLGA microsphere formulations of Olanzapine were characterized on the basis of their in vitro behavior at 37°C, using a dialysis based method, with the goal of obtaining an IVIVC. In vivo profiles were determined by deconvolution (Nelson-Wagner method and using fractional AUC. The in vitro and in vivo release profiles exhibited the same rank order of drug release. Further, in vivo profiles obtained with both approaches were nearly superimposable, suggesting that fractional AUC could be used as an alternative to the Nelson-Wagner method. A comparison of drug release profiles for the four formulations revealed that the in vitro profile lagged slightly behind in vivo release, but the results were not statistically significant (P0.96 between in vitro release and in vivo measurements confirmed the excellent relationship between in vitro drug release and the amount of drug absorbed in vivo. The results of this study suggest that proper selection of an in vitro method will greatly aid in establishing a Level A IVIVC for long acting injectables.

  8. Automated characterization of glass microspheres used for laser fusion experiments

    International Nuclear Information System (INIS)

    Tajima, Tsuyoshi; Norimatsu, Takayoshi; Izawa, Yasukazu; Yamanaka, Chiyoe.

    1985-01-01

    In laser fusion experiments glass microspheres of 100 to 1000 μm in diameter and 1 to 20 μm in wall thickness are most commonly used as fuel containers. The glass microspheres should be characterized precisely to meet stringent experimental requirements. Much time is consumed to characterize and select good quality spheres among thousands of spheres. We have developed an automated system to characterize and select glass microspheres. The system consists of charger, quadrupole rail, image processing and X-Y stage control with micro-computer. Total processing time primarily depends on the time required for image analysis, which should be compromised with the accuracy of characterization. The time for simple characterization requires about 10 sec. at present. (author)

  9. Preparation of alumina microspheres. Its application as in inorganic exchanger

    Energy Technology Data Exchange (ETDEWEB)

    Santos, W.R. dos; Abrao, A [Instituto de Pesquisas Energeticas e Nucleares, Sao Paulo (Brazil). Centro de Engenharia Quimica

    1980-01-01

    Inorganic exchangers are widely used for adsorption and column partition chromatography. The main difficulty of using commercial alumina (in powder) for column chromatography is related to its packing, and the operations through the column become diffcult and time-consuming; also it turns to be virtually impossible to use large dimension columns. In order to eliminate these problems, a process for the preparation of alumina microspheres was developed as an adaptation of a similar process used to prepare nuclear fuel microspheres (UO/sub 2/, ThO/sub 2/). The flowsheet of this process is presented together with the analytical results of sphericity after calcination, granulometry, density and characterization by X-ray diffractometry. Solubility tests showed that the so-prepared microspheres are well resistant to strong acids and bases; retention tests showed their efficiency, mainly to copper.

  10. Electrodepositing of Au on hollow PS micro-spheres

    International Nuclear Information System (INIS)

    Sun Jingyuan; Zhang Yunwang; Du Kai; Wan Xiaobo; Xiao Jiang; Zhang Wei; Zhang Lin; Chen Jing

    2010-01-01

    Using the self-regulating new micro-sphere electrodepositing device, the techniques of electrodepositing gold on hollow PS micro-spheres were established. The experiment was carried out under the following conditions: voltage was about 0.7 ∼ 0.8 V, current density was 2.0 mA · cm -2 , the temperature was 45 degree C, cathode rotating rate was 250 r · min -1 , flow rate of the solution was 7 mL · min -1 · cm -2 . Hollow gold-plated micro-spheres were prepared with well spherical symmetry, uniform thickness and surface smoothness under 500 nm. The speed of the gold depositing was 6 μm · h -1 . (authors)

  11. Radiolabeled microsphere measurements of alveolar bone blood flow in dogs

    International Nuclear Information System (INIS)

    Kaplan, M.L.; Jeffcoat, M.K.; Goldhaber, P.

    1978-01-01

    Radiolabeled microspheres were injected into the left cardiac ventricle in healthy adult dogs to quantify blood in maxillary and mandibular alveolar bone. Heart rate, arterial blood pressure and pulse contour were monitored throughout each experiment. Blood flow in maxillary alveolar bone was more than 30 % greater (p<.001) than in mandibular alveolar bone. Alveolar bone blood flow (mean +- S.D.) measured as ml/min per gram was 0.12 +- .02 in the maxilla compared to 0.09 +- .02 in the mandible. The cardiovascular parameters monitored were constant immediately prior to the injection of microspheres and remained unchanged during and following injection. It is possible that radiolabeled microspheres can be used to quantify the circulatory changes in alveolar bone during the development of destructive periodontal disease in dogs. (author)

  12. Fracture properties and heat resistance of ceramics consisting of microspheres of stabilized zirconium dioxide

    International Nuclear Information System (INIS)

    Krasulin, Yu.L.; Barinov, S.M.; Ivanov, A.B.; Timofeev, V.N.; Grevtsev, S.N.; Ivanov, D.A.

    1980-01-01

    Determined were effective specific fracture work, critical coefficient of stress intensity in the upper point of the fracture, strength and heat resistance during heat changes (20-1300 deg C) of the material produced by sintering stabilized zirconium dioxide microspheres. Dependence of these characteristics on granulometric composition of microspheres was determined. It was ascertained that the additional introduction of large microspheres into the bulk of small microspheres increased the metal fracture work. Specific work of material fracture progress exceeded specific work of fracture motion initiation. High value of fracture work together with high strength permits to use the material formed of microspheres as structural ceramics

  13. Temperature influence in crystallinity of polymer microspheres; Influencia da temperatura na cristalinidade de microesferas polimericas

    Energy Technology Data Exchange (ETDEWEB)

    Rezende, Cristiane de P.; Novack, Katia M., E-mail: knovack@iceb.ufop.br [Universidade Federal de Ouro Preto - UFOP, ICEB, DEQUI, Ouro Preto, MG (Brazil)

    2011-07-01

    Drug delivery technology is evolving through the creation of new techniques of drug delivery effectively. The new methods used in drugs administration are based in microencapsulation process. Microsphere encapsulation modifies drug delivery bringing benefits and efficiency. In this work has been evaluated the influence of temperature in microspheres preparation. Microspheres were obtained by PMMA-co-PEG (COP) copolymer with indomethacin inserted in polymer matrix. Samples were characterized by SEM, DSC and XRD. SEM micrographs confirmed the formation of different sizes of microspheres and it was verified that higher temperatures make more crystalline microspheres. (author)

  14. Cephradin-plaga microspheres for sustained delivery to cattle.

    Science.gov (United States)

    Ustariz-Peyret, C; Coudane, J; Vert, M; Kaltsatos, V; Boisramé, B

    1999-01-01

    In the field of controlled drug delivery, most of the reported work is aimed at introducing new systems, or at providing basic information on the critical parameters which affect release profiles in vitro and occasionally in vivo. The situation is totally different when one wants to fulfil the specific requirements imposed by the marketing of a sustained release device to be used in humans or in animals eaten by human beings. The control of the release characteristics is then a difficult challenge. In this work, attempts were made to combine cephradin, a hydrophilic beta-lactam antibiotic, and bioresorbable polymeric matrices of a poly(alpha-hydroxy acid) in the form of microspheres with the aim of delivering the antibiotic to cattle at a dose rate of 4-5 mg/kg/day over a 3-4 days period after i.m. injection. PLAGA aliphatic polyesters were selected because they are already FDA approved as matrices. The solvent evaporation technique using PVA as the emulsion stabilizer was selected because it is efficient and can be extended to an industrial scale. Various experimental conditions were used in order to obtain the highest encapsulation yields compatible with the desired specifications. Decreasing the volume of the aqueous phase and adding a water-miscible organic solvent/non-solvent of cephradin failed. In contrast, microspheres containing up to 30% cephradin were prepared after addition of sodium chloride to the aqueous dispersing phase. The amount of entrapped drug was raised to 40% by decreasing the temperature and the pressure. Preliminary investigations using dogs showed that 20% cephradin microspheres prepared under these conditions extended the presence of cephradin in the blood circulation up to 48 h. Increasing the load led to higher blood concentrations but shorter sustained release. The fact that the microspheres were for cattle limited the volume of the injection and thus the amount of microspheres to be administered. The other limiting factors were

  15. Use of molecular beams to support microspheres during plasma coating

    International Nuclear Information System (INIS)

    Crane, J.K.; Smith, R.D.; Johnson, W.L.; Letts, S.A.; Korbel, G.R.; Krenick, R.M.

    1980-01-01

    Spherical laser fusion targets can be levitated on beams of Ar or other gas atoms. This is an especially useful and reliable technique for supporting microspheres during plasma coating or plasma etching. The reliability of this technique is principally the result of two things: the success of a special centering device which provides a lateral, stabilizing force on the levitated microspheres; and a gas handling system which is capable of controlling levitation gas flow in the microtorr liter/sec range. We have determined that the operational regime of this device is that of Knudsen's flow. This knowledge of the flow characteristics has been important in developing this device

  16. Oxaliplatin loaded PLAGA microspheres: design of specific release profiles.

    Science.gov (United States)

    Lagarce, F; Cruaud, O; Deuschel, C; Bayssas, M; Griffon-Etienne, G; Benoit, J

    2002-08-21

    Oxaliplatin loaded PLAGA microspheres have been prepared by solvent extraction process. Parameters affecting the release kinetics in vitro have been studied in order to design specific release profiles suitable for direct intra-tumoral injection. By varying the nature and the relative proportions of different polymers we managed to prepare microspheres with good encapsulation efficiency (75-90%) and four different release profiles: zero order kinetics (type II) and the classical sigmoïd release profile with three different sizes of plateau and burst. These results, if correlated with in vivo activity, are promising to enhance effectiveness of local tumor treatment.

  17. UO2 microspheres obtainment through the internal gelation methods

    International Nuclear Information System (INIS)

    Sterba, M.E.; Gomez Constenla, A.

    1987-01-01

    UO 2 microspheres obtainment process through the internal gelation method which allows the spheres' obtainment of uniform size is detailed herein, varying the same among 0.3 and 1.7 mm of diameter. The sintered density reaches 10.78 g/cm 3 , permitting the fuels fabrication dispersed and vibro-compacted fuels. The trichloroethylene use implementation as gelation agent is described, thus reducing the number of stages in the microspheres fabrication. At the same time, the uranium sun composition has been modified so as to be compatible with the use solvent. (Author)

  18. Optical diffraction by ordered 2D arrays of silica microspheres

    Science.gov (United States)

    Shcherbakov, A. A.; Shavdina, O.; Tishchenko, A. V.; Veillas, C.; Verrier, I.; Dellea, O.; Jourlin, Y.

    2017-03-01

    The article presents experimental and theoretical studies of angular dependent diffraction properties of 2D monolayer arrays of silica microspheres. High-quality large area defect-free monolayers of 1 μm diameter silica microspheres were deposited by the Langmuir-Blodgett technique under an accurate optical control. Measured angular dependencies of zeroth and one of the first order diffraction efficiencies produced by deposited samples were simulated by the rigorous Generalized Source Method taking into account particle size dispersion and lattice nonideality.

  19. Excitation of resonances of microspheres on an optical fiber

    Science.gov (United States)

    Serpengüzel, A.; Arnold, S.; Griffel, G.

    1995-04-01

    Morphology-dependent resonances (MDR's) of solid microspheres are excited by using an optical fiber coupler. The narrowest measured MDR linewidths are limited by the excitation laser linewidth ( < 0.025 nm). Only MDR's, with an on-resonance to off-resonance intensity ratio of 104, contribute to scattering. The intensity of various resonance orders is understood by the localization principle and the recently developed generalized Lorentz-Mie theory. The microsphere fiber system has potential for becoming a building block in dispersive microphotonics. The basic physics underlying our approach may be considered a harbinger for the coupling of active photonic microstructures such as microdisk lasers.

  20. Controlled Synthesis of Hierarchically Assembled Porous ZnO Microspheres with Enhanced Gas-Sensing Properties

    Directory of Open Access Journals (Sweden)

    Shengsheng You

    2015-01-01

    Full Text Available The ZnO microspheres constructed by porous nanosheets were successfully synthesized by calcinating zinc hydroxide carbonate (ZHC microspheres obtained by a sample hydrothermal method. The samples were characterized in detail with scanning electron microscopy (SEM, transmission electron microscopy (TEM, X-ray diffraction (XRD, and thermogravimetric and differential scanning calorimetry (TG-DSC. The results indicated that the prepared ZnO microspheres were well crystalline with wurtzite hexagonal phase. The effects of reaction time, temperature, the amount of trisodium citrate, and urea on the morphology of ZnO microspheres were studied. The formation mechanism of porous ZnO microspheres was discussed. Furthermore, the gas-sensing properties for detection of organic gas of the prepared porous ZnO microspheres were investigated. The results indicated that the prepared porous ZnO microspheres exhibited high gas-sensing properties for detection of ethanol gas.

  1. Modified composite microspheres of hydroxyapatite and poly(lactide-co-glycolide) as an injectable scaffold

    International Nuclear Information System (INIS)

    Hu, Xixue; Shen, Hong; Yang, Fei; Liang, Xinjie; Wang, Shenguo; Wu, Decheng

    2014-01-01

    The compound of hydroxyapatite-poly(lactide-co-glycolide) (HA-PLGA) was prepared by ionic bond between HA and PLGA. HA-PLGA was more stable than the simple physical blend of hydroxyapatite and poly(lactide-co-glycolide) (HA/PLGA). The surface of HA-PLGA microsphere fabricated by an emulsion–solvent evaporation method was rougher than that of HA/PLGA microspheres. Moreover, surface HA content of HA-PLGA microspheres was more than that of HA/PLGA microspheres. In vitro mouse OCT-1 osteoblast-like cell culture results showed that the HA-PLGA microspheres clearly promoted osteoblast attachment, proliferation and alkaline phosphatase activity. It was considered that surface rich HA component and rough surface of HA-PLGA microsphere enhanced cell growth and differentiation. The good cell affinity of the HA-PLGA microspheres indicated that they could be used as an injectable scaffold for bone tissue engineering.

  2. Modified composite microspheres of hydroxyapatite and poly(lactide-co-glycolide) as an injectable scaffold

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Xixue [BNLMS, State Key Laboratory of Polymer Physics and Chemistry, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190 (China); CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, National Center for Nanoscience and Technology, Beijing 100190 (China); Shen, Hong, E-mail: shenhong516@iccas.ac.cn [BNLMS, State Key Laboratory of Polymer Physics and Chemistry, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190 (China); Yang, Fei [BNLMS, State Key Laboratory of Polymer Physics and Chemistry, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190 (China); Liang, Xinjie [CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, National Center for Nanoscience and Technology, Beijing 100190 (China); Wang, Shenguo, E-mail: wangsg@iccas.ac.cn [BNLMS, State Key Laboratory of Polymer Physics and Chemistry, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190 (China); Wu, Decheng, E-mail: dcwu@iccas.ac.cn [BNLMS, State Key Laboratory of Polymer Physics and Chemistry, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190 (China)

    2014-02-15

    The compound of hydroxyapatite-poly(lactide-co-glycolide) (HA-PLGA) was prepared by ionic bond between HA and PLGA. HA-PLGA was more stable than the simple physical blend of hydroxyapatite and poly(lactide-co-glycolide) (HA/PLGA). The surface of HA-PLGA microsphere fabricated by an emulsion–solvent evaporation method was rougher than that of HA/PLGA microspheres. Moreover, surface HA content of HA-PLGA microspheres was more than that of HA/PLGA microspheres. In vitro mouse OCT-1 osteoblast-like cell culture results showed that the HA-PLGA microspheres clearly promoted osteoblast attachment, proliferation and alkaline phosphatase activity. It was considered that surface rich HA component and rough surface of HA-PLGA microsphere enhanced cell growth and differentiation. The good cell affinity of the HA-PLGA microspheres indicated that they could be used as an injectable scaffold for bone tissue engineering.

  3. 16. PRE-OPERATIVE BLADDER IRRIGATION

    African Journals Online (AJOL)

    Esem

    effectiveness of using preoperative bladder irrigation with 1% povidone iodine in reducing ... consenting patient who presented to the department of surgery for open ..... infections in a tertiary care center in south-western. Nigeria. International ...

  4. Preoperative bowel preparation in children: Polyethylene glycol ...

    African Journals Online (AJOL)

    Preoperative bowel preparation in children: Polyethylene glycol versus normal saline. ... In children, (is this standard of care?: this method is mostly followed) this is usually ... Patients and Methods: Thirty patients, admitted in the Department of ...

  5. Preoperative Alcohol Consumption and Postoperative Complications

    DEFF Research Database (Denmark)

    Eliasen, Marie; Grønkjær, Marie; Skov-Ettrup, Lise Skrubbeltrang

    2013-01-01

    OBJECTIVE:: To systematically review and summarize the evidence of the association between preoperative alcohol consumption and postoperative complications elaborated on complication type. BACKGROUND:: Conclusions in studies on preoperative alcohol consumption and postoperative complications have...... been inconsistent. METHODS:: A systematic review and meta-analysis based on a search in MEDLINE, EMBASE, CINAHL, and PsycINFO citations. Included were original studies of the association between preoperative alcohol consumption and postoperative complications occurring within 30 days of the operation.......30-2.49), prolonged stay at the hospital (RR = 1.24; 95% CI: 1.18-1.31), and admission to intensive care unit (RR = 1.29; 95% CI: 1.03-1.61). Clearly defined high alcohol consumption was associated with increased risk of postoperative mortality (RR = 2.68; 95% CI: 1.50-4.78). Low to moderate preoperative alcohol...

  6. Evaluation of nonradioactive, colored microspheres for measurement of regional myocardial blood flow in dogs

    International Nuclear Information System (INIS)

    Hale, S.L.; Alker, K.J.; Kloner, R.A.

    1988-01-01

    Measurement of regional myocardial blood flow (RMBF) is crucial in experimental studies of myocardial ischemia and reperfusion in dogs. The standard measurement technique uses radioactive microspheres; however, not all institutions are able to dispose of radioactive waste and therefore cannot make use of this method. We tested a new, nonradioactive microsphere, labeled with colors instead of nuclides. Simultaneous blood flow measurements with two nuclide-labeled and two colored microspheres were performed after coronary occlusion in dogs. Both techniques show a within-method correlation of r greater than 0.98. Duplicate variability for paired RMBF values in 80 samples was 8.7 +/- 0.1% when computed with radioactive microspheres and 13.2 +/- 1.8% when computed with colored microspheres. There was a good correlation in the measurement of RMBF between the radioactive- and colored-microsphere methods (r = 0.98). The best-fitting linear regression line was expressed by the formula: Colored-microsphere RMBF = 1.11 (radioactive-microsphere RMBF)-0.02. When measured by colored microspheres, RMBF was approximately 8% higher than when computed with radioactive microspheres for blood flow values of 0-2 ml/min/g. When blood flow was increased pharmacologically to levels of 2-7.5 ml/min/g, colored microspheres yielded blood flow values 39% higher than the values computed by radioactive microspheres. We conclude that the nonradioactive, colored-microsphere method correlates with the radioactive technique, but at high flows, it yields values greater than those obtained with radioactive microspheres

  7. Surface modification of cyclomatrix polyphosphazene microsphere by thiol-ene chemistry and lectin recognition

    International Nuclear Information System (INIS)

    Chen, Chen; Zhu, Xue-yan; Gao, Qiao-ling; Fang, Fei; Huang, Xiao-jun

    2016-01-01

    Graphical abstract: A new synthetic route leading to polyphosphazene cyclomatrix microsphere with various functional groups has achieved via thiol-ene click modification. Herein, hexacholorocyclophosphazene (HCCP) crosslinked with bisphenol-S and 4,4′-diallyl bisphenol-S to generate broadly dispersed microspheres. Thiol-ene modification under UV irradiation not only presented high efficiency and flexibility for post-functionalization, but also imposed no harm on global morphology and crosslinked skeleton of such microspheres. - Highlights: • Functional polyphosphazene microspheres with high chemical flexibility were synthesized by thiol-ene modification. • Polyphosphazene microspheres possessed high thermal stability. • Glycosylated polyphosphazene microspheres showed affinity to lectin Con-A, which inferred potential application in biomedicine. - Abstract: A new synthetic route leading to functional polyphosphazene cyclomatrix microsphere has been developed via thiol-ene click modification. Hexacholorocyclophosphazene (HCCP) was crosslinked with both bisphenol-S and 4,4′-diallyl bisphenol-S to obtain vinyl polyphosphazene microspheres (VPZM) in order to ensure high crosslinking degree and introduce vinyl moieties. Compared to the microspheres obtained by HCCP and bisphenol-S, the size of VPZM was broadly dispersed from 400 nm to 1.40 μm. Thiol-ene click reactions were carried out to attach functional groups, such as glucosyl, carboxyl, ester and dodecyl groups onto polyphosphazene microspheres, which demonstrated no change in morphology and size after modification. Solid state NMR (SSNMR) and Fourier transform infrared spectoscopy (FT-IR) results showed that the vinyl moieties were introduced in the period of crosslinking and functionalization was also successful via click reactions. Moreover, the microspheres presented a little difference in thermal properties after modification. Concanavalin A (Con-A) fluorescent adsorption was also observed for

  8. Polymer based microspheres of aceclofenac as sustained release parenterals for prolonged anti-inflammatory effect

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, Manpreet; Sharma, Sumit; Sinha, VR, E-mail: sinha_vr@rediffmail.com

    2017-03-01

    Poly(lactic-co-glycolic acid) (PLGA) (75:25) and polycaprolactone (PCL) microspheres were fabricated for prolonged release of aceclofenac by parenteral administration. Microspheres encapsulating aceclofenac were designed to release the drug at controlled rate for around one month. Biodegradable microspheres were prepared by solvent emulsification evaporation method in different polymer:drug ratios (1:1, 2:1 and 3:1). After drug loading, PLGA and PCL microspheres showed a controlled size distribution with an average size of 11.75 μm and 3.81 μm respectively and entrapment efficiency in the range of 90 ± 0.72% to 91.06 ± 4.01% with PLGA and 83.01 ± 2.13% to 90.4 ± 2.11% with PCL. Scanning electron microscopy has confirmed good spherical structures of microspheres. The percent yield of biodegradable polymeric microspheres ranged between 30.95 ± 10.14% to 92.84 ± 3.15% and 47.33 ± 4.72% to 80 ± 3.60% for PLGA and PCL microspheres respectively. PLGA microspheres followed Higuchi release pattern while Korsmeyer-Peppas explained the release pattern of PCL microspheres. Stability studies of microspheres were also carried out by storing the preparations at 2-8 °C for 30, 60 and 90 days and evaluating them for entrapment efficiency, residual drug content and polymer drug compatability. In-vivo studies showed significant anti-inflammatory activity of microspheres upto 48 hours using the carrageenan induced rat paw oedema model. - Highlights: • PLGA and PCL polymeric microspheres for parenteral prolonged drug delivery system were formulated. • Polymeric microspheres were characterized physically and drug excipient incompatability. • Three months accelerated stability studies were carried for drug loaded polymeric microspheres. • Pharmacodynamic studies prove the rationality of sustained therapeutic effect of designed drug delivery system.

  9. Surface modification of cyclomatrix polyphosphazene microsphere by thiol-ene chemistry and lectin recognition

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chen; Zhu, Xue-yan; Gao, Qiao-ling; Fang, Fei; Huang, Xiao-jun, E-mail: hxjzxh@zju.edu.cn

    2016-11-30

    Graphical abstract: A new synthetic route leading to polyphosphazene cyclomatrix microsphere with various functional groups has achieved via thiol-ene click modification. Herein, hexacholorocyclophosphazene (HCCP) crosslinked with bisphenol-S and 4,4′-diallyl bisphenol-S to generate broadly dispersed microspheres. Thiol-ene modification under UV irradiation not only presented high efficiency and flexibility for post-functionalization, but also imposed no harm on global morphology and crosslinked skeleton of such microspheres. - Highlights: • Functional polyphosphazene microspheres with high chemical flexibility were synthesized by thiol-ene modification. • Polyphosphazene microspheres possessed high thermal stability. • Glycosylated polyphosphazene microspheres showed affinity to lectin Con-A, which inferred potential application in biomedicine. - Abstract: A new synthetic route leading to functional polyphosphazene cyclomatrix microsphere has been developed via thiol-ene click modification. Hexacholorocyclophosphazene (HCCP) was crosslinked with both bisphenol-S and 4,4′-diallyl bisphenol-S to obtain vinyl polyphosphazene microspheres (VPZM) in order to ensure high crosslinking degree and introduce vinyl moieties. Compared to the microspheres obtained by HCCP and bisphenol-S, the size of VPZM was broadly dispersed from 400 nm to 1.40 μm. Thiol-ene click reactions were carried out to attach functional groups, such as glucosyl, carboxyl, ester and dodecyl groups onto polyphosphazene microspheres, which demonstrated no change in morphology and size after modification. Solid state NMR (SSNMR) and Fourier transform infrared spectoscopy (FT-IR) results showed that the vinyl moieties were introduced in the period of crosslinking and functionalization was also successful via click reactions. Moreover, the microspheres presented a little difference in thermal properties after modification. Concanavalin A (Con-A) fluorescent adsorption was also observed for

  10. Perfusion measurements with radioactively labelled microspheres

    International Nuclear Information System (INIS)

    Schosser, R.

    1980-01-01

    The technique and the evaluation of the microsphere-method are comprehensively represented in theory and practice. Some changes and new concepts are discussed, besides the known foundations and techniques, that assure an essential methodic improvement resp. practical simplifications. Two new formulas are derived within the frame of the theoretical principles, by which the absolute flux of shorts can be calculated, i.e. on the one hand in the case of known and on the other hand in the case of unknown applied amount of indicator. The determination of the optimal indicator dose is defined and formulated mathematically with respect to the experimental conditions to be expected. The matrix method was designed for the analysis of complex gamma spectra. Hereby there is no selective error accumulation in the case of low energy radio nuclids contrary to the so far exclusively used stripping technique. The number of possible error quantities was reduced by one resp. two variables. The error of particular radio nuclid components is quantitatively computed as standard deviation by means of the theory of approximated systems of linear equations. The external measurement of distance was developed. This technique is less susceptible for errors as the aliquota i.e. whole body measurement technique. Additionally less measurement time is needed. A flexible computer program for a desk top computer was developped for the evaluation. The data from the gamma spectrometer are recorded on tipe and automatically read in by the computer. The manual input are limited to the weights of the organs and some control parameter. The output is made by a clearly arranged table by means of a lineprinter. (orig./MG) [de

  11. Recombinant Gelatin Microspheres : Novel Formulations for Tissue Repair?

    NARCIS (Netherlands)

    Tuin, Annemarie; Kluijtmans, Sebastiaan G.; Bouwstra, Jan B.; Harmsen, Martin C.; Van Luyn, Marja J. A.

    Microspheres (MSs) can function as multifunctional scaffolds in different approaches of tissue repair (TR), as a filler, a slow-release depot for growth factors, or a delivery vehicle for cells. Natural cell adhesion-supporting extracellular matrix components like gelatin are good materials for

  12. Use of molecular beams to support microspheres during plasma coating

    International Nuclear Information System (INIS)

    Crane, J.K.; Smith, R.D.; Johnson, W.L.; Jordan, C.W.; Letts, S.A.; Korbel, G.R.; Krenik, R.M.

    1980-01-01

    Spherical targets can be levitated on beams of Ar or other gas atoms. This is an especially useful technique for supporting microspheres during plasma coating and processing. Measurements of gas flow and pressure indicate that the levitation device operates in the regime of Knudsen's flow. This device is currently being used in the development of future generation laser targets

  13. Albumin-heparin microspheres as carriers for cytostatic agents

    NARCIS (Netherlands)

    Cremers, Harry; Feijen, Jan; Kwon, G.; Bae, Y.H.; Kim, S.W.; Noteborn, H.P.J.M.; Mcvie, J.G.

    1990-01-01

    Much work has been done on adriamycin-loaded albumin microspheres (Alb-MS) for chemoembolization [1–4], the rationale being that site-specific drug delivery may increase the therapeutic efficacy of the drug. Alb-Ms are being investigated because of their biocompatibility and because the degradation

  14. Fabrication of periodically ordered diamond nanostructures by microsphere lithography

    Czech Academy of Sciences Publication Activity Database

    Domonkos, Mária; Ižák, Tibor; Štolcová, L.; Proška, J.; Kromka, Alexander

    2014-01-01

    Roč. 251, č. 12 (2014), s. 2587-2592 ISSN 0370-1972 R&D Projects: GA ČR(CZ) GBP108/12/G108 Institutional support: RVO:68378271 Keywords : CVD growth * diamond * microsphere lithography * selective area deposition Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.489, year: 2014

  15. loaded Eudragit RL 100 Microspheres Prepared by an Emulsion

    African Journals Online (AJOL)

    Erah

    drug release profiles of the microspheres at pH 1.2 showed poor drug release characteristics while at. pH 6.8 ... drug delivery, improve bioavailability and stability and target drug to ... The factors affecting particle size, drug loading and drug.

  16. BIOCOMPATIBLE FLUORESCENT MICROSPHERES: SAFE PARTICLES FOR MATERIAL PENETRATION STUDIES

    Energy Technology Data Exchange (ETDEWEB)

    farquar, G; Leif, R

    2008-09-12

    Biocompatible polymers with hydrolyzable chemical bonds are being used to produce safe, non-toxic fluorescent microspheres for material penetration studies. The selection of polymeric materials depends on both biocompatibility and processability, with tailored fluorescent properties depending on specific applications. Microspheres are composed of USFDA-approved biodegradable polymers and non-toxic fluorophores and are therefore suitable for tests where human exposure is possible. Micropheres are being produced which contain unique fluorophores to enable discrimination from background aerosol particles. Characteristics that affect dispersion and adhesion can be modified depending on use. Several different microsphere preparation methods are possible, including the use of a vibrating orifice aerosol generator (VOAG), a Sono-Tek atomizer, an emulsion technique, and inkjet printhead. The advantages and disadvantages of each method will be presented and discussed in greater detail along with fluorescent and charge properties of the aerosols. Applications for the fluorescent microspheres include challenges for biodefense system testing, calibrants for biofluorescence sensors, and particles for air dispersion model validation studies.

  17. Biotemplate synthesis of monodispersed iron phosphate hollow microspheres

    International Nuclear Information System (INIS)

    Cao Feng; Li Dongxu

    2010-01-01

    Monodispersed iron phosphate hollow microspheres with a high degree of crystallization were prepared through a facile in situ deposition method using rape pollen grains as a biotemplate. The functional group on the surface of the pollen grains could adsorb Fe 3+ , which provided the nucleation sites for growth of iron phosphate nanoparticles. After being sintered at 600 deg. C for 10 h, the pollen grains were removed and iron phosphate hollow microspheres were obtained. A scanning electron microscope and x-ray diffraction were applied to characterize the morphology and crystalline structure of the pollen grains, iron phosphate-coated pollen grains and iron phosphate hollow microspheres. Differential scanning calorimetry and thermogravity analyses were performed to investigate the thermal behavior of the iron phosphate-coated pollen grains during the calcinations. Energy dispersive spectroscopy and Fourier transform infrared spectroscopy were utilized to investigate the interaction between the pollen grains and iron phosphate. The effect of the pollen wall on the surface morphology of these iron phosphate hollow microspheres was also proven in this work.

  18. Biotemplate synthesis of monodispersed iron phosphate hollow microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Cao Feng; Li Dongxu, E-mail: dongxuli@njut.edu.c [College of Materials Science and Engineering, Nanjing University of Technology, Jiangsu Nanjing 210009 (China)

    2010-03-15

    Monodispersed iron phosphate hollow microspheres with a high degree of crystallization were prepared through a facile in situ deposition method using rape pollen grains as a biotemplate. The functional group on the surface of the pollen grains could adsorb Fe{sup 3+}, which provided the nucleation sites for growth of iron phosphate nanoparticles. After being sintered at 600 deg. C for 10 h, the pollen grains were removed and iron phosphate hollow microspheres were obtained. A scanning electron microscope and x-ray diffraction were applied to characterize the morphology and crystalline structure of the pollen grains, iron phosphate-coated pollen grains and iron phosphate hollow microspheres. Differential scanning calorimetry and thermogravity analyses were performed to investigate the thermal behavior of the iron phosphate-coated pollen grains during the calcinations. Energy dispersive spectroscopy and Fourier transform infrared spectroscopy were utilized to investigate the interaction between the pollen grains and iron phosphate. The effect of the pollen wall on the surface morphology of these iron phosphate hollow microspheres was also proven in this work.

  19. Hollow microspheres with a tungsten carbide kernel for PEMFC application.

    Science.gov (United States)

    d'Arbigny, Julien Bernard; Taillades, Gilles; Marrony, Mathieu; Jones, Deborah J; Rozière, Jacques

    2011-07-28

    Tungsten carbide microspheres comprising an outer shell and a compact kernel prepared by a simple hydrothermal method exhibit very high surface area promoting a high dispersion of platinum nanoparticles, and an exceptionally high electrochemically active surface area (EAS) stability compared to the usual Pt/C electrocatalysts used for PEMFC application.

  20. Processing and Characterization of Sol-Gel Cerium Oxide Microspheres

    Energy Technology Data Exchange (ETDEWEB)

    McClure, Zachary D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Padilla Cintron, Cristina [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-09-27

    Of interest to space exploration and power generation, Radioisotope Thermoelectric Generators (RTGs) can provide long-term power to remote electronic systems without the need for refueling or replacement. Plutonium-238 (Pu-238) remains one of the more promising materials for thermoelectric power generation due to its high power density, long half-life, and low gamma emissions. Traditional methods for processing Pu-238 include ball milling irregular precipitated powders before pressing and sintering into a dense pellet. The resulting submicron particulates of Pu-238 quickly accumulate and contaminate glove boxes. An alternative and dust-free method for Pu-238 processing is internal gelation via sol-gel techniques. Sol-gel methodology creates monodisperse and uniform microspheres that can be packed and pressed into a pellet. For this study cerium oxide microspheres were produced as a surrogate to Pu-238. The similar electronic orbitals between cerium and plutonium make cerium an ideal choice for non-radioactive work. Before the microspheres can be sintered and pressed they must be washed to remove the processing oil and any unreacted substituents. An investigation was performed on the washing step to find an appropriate wash solution that reduced waste and flammable risk. Cerium oxide microspheres were processed, washed, and characterized to determine the effectiveness of the new wash solution.

  1. Preparation and Characterization of Sugar Cane Wax Microspheres ...

    African Journals Online (AJOL)

    HP

    scanning calorimetry (DSC) as well as for drug loading, and in vitro and in vivo release in albino sheeps. Results: SEM images .... Rolex, India), and the sphericity factor (S) was calculated using ... using a fully validated high performance liquid ... Pharmacokinetic and data analysis ... microspheres exerts an influence on the.

  2. Preparation and Characterization of Colon-Specific Microspheres of ...

    African Journals Online (AJOL)

    Purpose: To prepare and evaluate colon specific drug delivery system of diclofenac sodium for highly localized delivery to the colon. Methods: The colon specific drug delivery system was prepared as matrix-type microspheres using Ethyl Cellulose (EC), Cellulose Acetate Phthalate (CAP), and Eudragit L 100-55 by the ...

  3. Method for forming microspheres for encapsulation of nuclear waste

    Science.gov (United States)

    Angelini, Peter; Caputo, Anthony J.; Hutchens, Richard E.; Lackey, Walter J.; Stinton, David P.

    1984-01-01

    Microspheres for nuclear waste storage are formed by gelling droplets containing the waste in a gelation fluid, transferring the gelled droplets to a furnace without the washing step previously used, and heating the unwashed gelled droplets in the furnace under temperature or humidity conditions that result in a substantially linear rate of removal of volatile components therefrom.

  4. Formulation and evaluation of matrix microspheres for simultaneous ...

    African Journals Online (AJOL)

    The prepared microspheres were characterized for their micromeritic properties and drug loading, as well as by infrared spectroscopy (IR), differential scanning calorimetry (DSC), x-ray powder diffractometry (XRD) and scanning electron microscopy (SEM). The in vitro release studies were performed in pH 7.4, phosphate ...

  5. Mucoadhesive microspheres: a promising tool in drug delivery.

    Science.gov (United States)

    Patil, Sanjay B; Sawant, Krutika K

    2008-10-01

    Mucoadhesive polymers have recently gained interest among pharmaceutical scientists as a means of improving drug delivery by promoting the residence time and contact time of the dosage form with the mucous membranes. Mucoadhesion is the process whereby synthetic and natural polymers adhere to mucosal surfaces in the body. If these materials are then incorporated into pharmaceutical formulations, drug absorption by mucosal cells may be enhanced or the drug will be released at the site for an extended period of time. Microspheres, in general, have the potential to be used for targeted and controlled release drug delivery; however, coupling of mucoadhesive properties to microspheres has additional advantages like, a much more intimate contact with the mucus layer, efficient absorption and enhanced bioavailability of the drugs due to a high surface to volume ratio. The present review describes the potential applications of mucoadhesive microspheres as a novel carrier system to improve drug delivery by various routes of administration like buccal, oral, nasal, ocular, vaginal and rectal, either for systemic or for local effects. The mucoadhesive polymers, methods of preparation of microspheres and their in vitro and in vivo evaluation are also described.

  6. Calcium carbonate microspheres as carriers for the anticancer drug camptothecin

    Energy Technology Data Exchange (ETDEWEB)

    Qiu, Neng [Division of Biomedical Engineering, School of Engineering, University of Glasgow, Glasgow, G12 8LT (United Kingdom); State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, West China Medical School, Sichuan University, Chengdu 610041 (China); Department of Bio-pharmaceutical Engineering, School of Chemical Engineering, Sichuan University, Chengdu ,610065 (China); Yin, Huabing, E-mail: huabing.yin@glasgow.ac.uk [Division of Biomedical Engineering, School of Engineering, University of Glasgow, Glasgow, G12 8LT (United Kingdom); Ji, Bozhi; Klauke, Norbert; Glidle, Andrew [Division of Biomedical Engineering, School of Engineering, University of Glasgow, Glasgow, G12 8LT (United Kingdom); Zhang, Yongkui; Song, Hang [Department of Bio-pharmaceutical Engineering, School of Chemical Engineering, Sichuan University, Chengdu ,610065 (China); Cai, Lulu; Ma, Liang; Wang, Guangcheng [State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, West China Medical School, Sichuan University, Chengdu 610041 (China); Chen, Lijuan, E-mail: lijuan17@hotmail.com [State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, West China Medical School, Sichuan University, Chengdu 610041 (China); Wang, Wenwen [State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, West China Medical School, Sichuan University, Chengdu 610041 (China)

    2012-12-01

    Biogenic calcium carbonate has come to the attention of many researchers as a promising drug delivery system due to its safety, pH sensitivity and the large volume of information already in existence on its medical use. In this study, we employed bovine serum albumin (BSA) as an additive to synthesize a series of porous calcium carbonate microspheres (CCMS). These spheres, identified as vaterite, are stable both in aqueous solutions and organic solvents. Camptothecin, an effective anticancer agent, was loaded into the CCMS by simple diffusion and adsorption. The camptothecin loaded CCMS showed sustained cell growth inhibitory activity and a pH dependent release of camptothecin. With a few hours, the release is negligible under physiological conditions (pH = 7.4) but almost complete at pH 4 to 6 (i.e. pHs found in lysosomes and solid tumor tissue respectively). These findings suggest that porous, biogenic calcium carbonate microspheres could be promising carriers for the safe and efficient delivery of anticancer drugs of low aqueous solubility. - Highlights: Black-Right-Pointing-Pointer BSA-doped calcium carbonate microspheres with porous structure were prepared. Black-Right-Pointing-Pointer Camptothecin was encapsulated in the spherical microparticles with encapsulation efficiency up to 11%. Black-Right-Pointing-Pointer The release of encapsulated camptothecin is pH dependent Black-Right-Pointing-Pointer In vitro studies showed an effective anticancer activity of the camptothecin- microspheres.

  7. Formulation and Optimization of Celecoxib-Loaded Microspheres ...

    African Journals Online (AJOL)

    factors in the preparation of celecoxib-loaded microspheres. Methods: ... made with biodegradable polymers, are ... filtration on Whatman filter paper no.1 and washed 4 - 5 times with n-hexane [11]. The product was then air-dried at room.

  8. Preparation and characterization of microspheres of albumin-heparin conjugates

    NARCIS (Netherlands)

    Kwon, Glen S.; Bae, You Han; Kim, Sung Wan; Cremers, Harry; Cremers, H.F.M.; Feijen, Jan

    1991-01-01

    Albumin-heparin microspheres have been prepared as a new drug carrier. A soluble albumin-heparin conjugate was synthesized by forming amide bonds between human serum albumin and heparin. After purification the albumin-heparin conjugate was crosslinked in a water-in-oil emulsion to form

  9. Novel fluorescent poly(glycidyl methacrylate) - silica microspheres

    Czech Academy of Sciences Publication Activity Database

    Grama, Silvia; Boiko, N.; Bilyy, R.; Klyuchivska, O.; Antonyuk, V.; Stoika, R.; Horák, Daniel

    2014-01-01

    Roč. 56, July (2014), s. 92-104 ISSN 0014-3057 R&D Projects: GA MŠk EE2.3.30.0029; GA MŠk(CZ) ED1.1.00/02.0109 Institutional support: RVO:61389013 Keywords : microspheres * silica * poly(glycidyl methacrylate) Subject RIV: CE - Biochemistry Impact factor: 3.005, year: 2014

  10. Fabrication of polystyrene hollow microspheres as laser fusion ...

    Indian Academy of Sciences (India)

    free from preheating problems and have emerged as good alternative to .... carry a system over the energy barrier comes from the Brownian motion of the ... This increase implies an increase in the electrical contribution to the free energy of the .... microsphere is mainly determined by rotational speed of the magnetic stirrer.

  11. Development of activity standard for 90Y microspheres

    CSIR Research Space (South Africa)

    Mo, L

    2005-08-01

    Full Text Available 90Y is a therapeutic radiopharmaceuticals used in the treatment of liver cancer following implantation via a catheter in the hepatic artery, 90Y microspheres are embolised in the microvasculature of liver cancer where they irradiate the tumour by a...

  12. Hollow mesoporous titania microspheres: New technology and enhanced photocatalytic activity

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Zhenliang; Wei, Wenrui; Wang, Litong [School of Chemical Engineering, Fuzhou University, Fuzhou 350108 (China); Hong, Ruoyu, E-mail: rhong@suda.edu.cn [School of Chemical Engineering, Fuzhou University, Fuzhou 350108 (China); College of Chemistry, Chemical Engineering and Materials Science & Key Laboratory of Organic Synthesis of Jiangsu Province, Soochow University, SIP, Suzhou 215123 (China)

    2015-12-01

    Graphical abstract: Schematic of the formation process of HTS. - Highlights: • Amino modified porous PS-DVB microspheres were used as templates to coat TiO{sub 2.} • The coating of TiO{sub 2} was conducted under regular changing atmospheric pressure. • The PS-DVB@TiO{sub 2} was calcinated first under nitrogen and then under air to get HTS. • The resultant products were provided with high surface area and excellent photocatalytic activity under UV irradiation. - Abstract: Hollow titania microspheres (HTS) were fabricated via a sol–gel process by coating the hydrolysis product of titanium tetrabutoxide (TBOT) onto the amino (–NH{sub 2}) modified porous polystyrene cross-linked divinyl benzene (PS-DVB) microspheres under changing atmospheric pressure, followed by calcination in nitrogen and air atmosphere. Particularly, the atmospheric pressure was continuously and regularly changed during the formation process of PS-DVB@TiO{sub 2} microspheres. Then the TiO{sub 2} particles were absorbed into the pores and onto the surface of PS-DVB as well. The resultant HTS (around 2 μm in diameter) featured a high specific surface area (84.37 m{sup 2}/g), anatase crystal and stable hollow microsphere structure, which led to high photocatalysis activity. The photocatalytic degradation of malachite green (MG) organic dye solution was conducted under ultraviolet (UV) light irradiation, which showed a high photocatalytic ability (81% of MG was degraded after UV irradiation for 88 min). Therefore, it could be potentially applied for the treatment of wastewater contaminated by organic pollutants.

  13. Yttrium-90 microspheres for the treatment of hepatocellular carcinoma.

    Science.gov (United States)

    Geschwind, Jean Francois H; Salem, Riad; Carr, Brian I; Soulen, Michael C; Thurston, Kenneth G; Goin, Kathleen A; Van Buskirk, Mark; Roberts, Carol A; Goin, James E

    2004-11-01

    Unresectable hepatocellular carcinoma is extremely difficult to treat. TheraSphere consists of yttrium-90 (a pure beta emitter) microspheres, which are injected into the hepatic arteries. This article reviews the safety and survival of patients with hepatocellular carcinoma who were treated with yttrium-90 microspheres. Eighty patients were selected from a database of 108 yttrium-90 microsphere-treated patients and were staged by using Child-Pugh, Okuda, and Cancer of the Liver Italian Program scoring systems. Patients were treated with local, regional, and whole-liver approaches. Survival from first treatment was analyzed with Kaplan-Meier and Cox regression methods. Adverse events and complications of treatment were coded by using the Southwest Oncology Group toxicity scoring system. Patients received liver doses ranging from 47 to 270 Gy. Thirty-two patients (40%) received more than 1 treatment. Survival correlated with pretreatment Cancer of the Liver Italian Program scores ( P = .002), as well as with the individual Cancer of the Liver Italian Program components, Child-Pugh class, alpha-fetoprotein levels, and percentage of tumor replacement. Patients classified as Okuda stage I (n = 54) and II (n = 26) had median survival durations and 1-year survival rates of 628 days and 63%, and 384 days and 51%, respectively ( P = .02). One patient died of liver failure judged as possibly related to treatment. Thus, in selected patients with hepatocellular carcinoma, yttrium-90 microsphere treatment is safe and well tolerated. On the basis of these results, a randomized controlled trial is warranted comparing yttrium-90 microsphere treatment with transarterial chemoembolization by using the Cancer of the Liver Italian Program system for prospective stratified randomization.

  14. Preparation and drug controlled release of porous octyl-dextran microspheres.

    Science.gov (United States)

    Hou, Xin; Liu, Yanfei

    2015-01-01

    In this work, porous octyl-dextran microspheres with excellent properties were prepared by two steps. Firstly, dextran microspheres were synthesized by reversed-phase suspension polymerization. Secondly, octyl-dextran microspheres were prepared by the reaction between dextran microspheres and ethylhexyl glycidyl ether and freezing-drying method. Porous structure of microspheres was formed through the interaction between octyl groups and organic solvents. The structure, morphology, dry density, porosity and equilibrium water content of porous octyl-dextran microspheres were systematically investigated. The octyl content affected the properties of microspheres. The results showed that the dry density of microspheres decreased from 2.35 to 1.21 g/ml, porosity increased from 80.68 to 95.05% with the octyl content increasing from 0.49 to 2.28 mmol/g. Meanwhile, the equilibrium water content presented a peak value (90.18%) when the octyl content was 2.25 mmol/g. Octyl-dextran microspheres showed high capacity. Naturally drug carriers play an important role in drug-delivery systems for their biodegradability, wide raw materials sources and nontoxicity. Doxorubicin (DOX) was used as a drug model to examine the drug-loading capacity of porous octyl-dextran microspheres. The drug-loading efficiency increased with the increase in microspheres/drug ratio, while the encapsulation efficiency decreased. When microspheres/drug mass ratio was 4/1, the drug-loading efficiency and encapsulation efficiency were 10.20 and 51.00%, respectively. The release rate of DOX increased as drug content and porosity increased. In conclusion, porous octyl-dextran microspheres were synthesized successfully and have the potential to serve as an effective delivery system in drug controlled release.

  15. FEMIC (Fibromes Embolises aux MICrospheres calibrees): Uterine Fibroid Embolization using Tris-acryl Microspheres. A French Multicenter Study

    International Nuclear Information System (INIS)

    Joffre, Francis; Tubiana, Jean-Michel; Pelage, Jean-Pierre

    2004-01-01

    Purpose: A French multicenter registry was set up to confirm the safety and efficacy of large calibrated tris-acryl gelatin microspheres for embolization of symptomatic fibroids. Methods: Technical recommendations included embolization using large microspheres (>500 μm) with no secondary embolization agent. Postprocedural pain, clinical improvement and adverse events were prospectively evaluated during a follow-up period of at least 6 months.Results: Eighty-five women complaining of fibroid-related symptoms entered the study. In seven women, a secondary embolization agent was used in addition to microspheres. Complete resolution of menorrhagia was achieved in 84% of women at 24 months and significant uterine and fibroid volume reductions were noted after 6 months (37% and 73%, respectively). Three women experienced definitive amenorrhea (4%) and two women required hysteroscopic resection of a fibroid. Eight women were treated by hysterectomy because of treatment failure. In seven of these women, treatment failure was explained by an additional cause of symptoms including diffuse adenomyosis, endometrial hyperplasia or ovarian artery supply to the fibroids.Conclusion: Limited uterine artery embolization using large microspheres has good clinical success rate with low postprocedural pain and complications. Women can expect excellent midterm results with a high level of symptom control and significant fibroid volume reduction. Confidence in the end-point recommended here may require the experience of several cases

  16. Robust platforms for creating organic-inorganic nanocomposite microspheres: decorating polymer microspheres containing mussel-inspired adhesion layers with inorganic nanoparticles.

    Science.gov (United States)

    Satoh, H; Saito, Y; Yabu, H

    2014-12-07

    We describe a method for creating robust and stable core-shell polymer microspheres decorated with inorganic (IO) nanoparticles (NPs) by a self-organization process and heterocoagulation using a mussel-inspired polymer adhesive layer between the IO NPs and the microspheres.

  17. Simulation Model of Microsphere Distribution for Selective Internal Radiation Therapy Agrees With Observations

    Energy Technology Data Exchange (ETDEWEB)

    Högberg, Jonas, E-mail: jonas.hogberg@radfys.gu.se [Department of Radiation Physics, Sahlgrenska Academy, University of Gothenburg, Gothenburg (Sweden); Rizell, Magnus [Department of Surgery, Sahlgrenska University Hospital, Gothenburg (Sweden); Hultborn, Ragnar; Svensson, Johanna [Department of Oncology, Sahlgrenska University Hospital, Gothenburg (Sweden); Henrikson, Olof [Department of Radiology, Sahlgrenska University Hospital, Gothenburg (Sweden); Mölne, Johan [Department of Pathology, Sahlgrenska University Hospital, Gothenburg (Sweden); Gjertsson, Peter [Department of Clinical Physiology, Sahlgrenska University Hospital, Gothenburg (Sweden); Bernhardt, Peter [Department of Radiation Physics, Sahlgrenska Academy, University of Gothenburg, Gothenburg (Sweden); Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg (Sweden)

    2016-10-01

    Purpose: To perform a detailed analysis of microsphere distribution in biopsy material from a patient treated with {sup 90}Y-labeled resin spheres and characterize microsphere distribution in the hepatic artery tree, and to construct a novel dichotomous bifurcation model for microsphere deposits and evaluate its accuracy in simulating the observed microsphere deposits. Methods and Materials: Our virtual model consisted of arteries that successively branched into 2 new generations of arteries at 20 nodes. The artery diameter exponentially decreased from the lowest generation to the highest generation. Three variable parameters were optimized to obtain concordance between simulations and measure microsphere distributions: an artery coefficient of variation (ACV) for the diameter of all artery generations and the microsphere flow distribution at the nodes; a hepatic tree distribution volume (HDV) for the artery tree; and an artery diameter reduction (ADR) parameter. The model was tested against previously measured activity concentrations in 84 biopsies from the liver of 1 patient. In 16 of 84 biopsies, the microsphere distribution regarding cluster size and localization in the artery tree was determined via light microscopy of 30-μm sections (mean concentration, 14 microspheres/mg; distributions divided into 3 groups with mean microsphere concentrations of 4.6, 14, and 28 microspheres/mg). Results: Single spheres and small clusters were observed in terminal arterioles, whereas large clusters, up to 450 microspheres, were observed in larger arterioles. For 14 microspheres/mg, the optimized parameter values were ACV=0.35, HDV = 50 cm{sup 3}, and ADR=6 μm. For 4.6 microspheres/mg, ACV and ADR decreased to 0.26 and 0 μm, respectively, whereas HDV increased to 130 cm{sup 3}. The opposite trend was observed for 28 microspheres/mg: ACV = 0.49, HDV = 20 cm{sup 3}, and ADR = 8 μm. Conclusion: Simulations and measurements reveal that microsphere clusters are

  18. Investigation of control conditions of uranium dioxide pellets sinterability through microspheres

    International Nuclear Information System (INIS)

    Assis, Gino de.

    1996-01-01

    Promotion or inhibition of ceramic powders sinterability, the decisive question in ceramic processing is approached in this dissertation. Each high density microsphere has been considered as a solid inclusion in a low density microspheres matrix, generating big pores. Such pores make it difficult for the pellets density due the fact that they are difficult to be eliminated. A master mixture, allowing the pellet densification in the projected range has been reached. Batches of microspheres have been observed sometimes with high apparent density and sometimes with low apparent density. This apparent density variation was attributed to changing the oxygen partial pressure during calcination under air atmosphere. It is evident that the control of the apparent density of the microspheres needs a further research in order to adjust the sinterability of the microspheres on the desired level.It was demonstrated that the produced microspheres do not have impurities levels that can promote its sinterability or avoid their use in nuclear area

  19. Characterization of unsaturated fatty acid sustained-release microspheres for long-term algal inhibition.

    Science.gov (United States)

    Ni, Lixiao; Jie, Xiaoting; Wang, Peifang; Li, Shiyin; Hu, Shuzhen; Li, Yiping; Li, Yong; Acharya, Kumud

    2015-02-01

    The unsaturated fatty acid (linoleic acid) sustained-release microspheres were prepared with linoleic acid (LA) using alginate-chitosan microcapsule technology. These LA sustained-release microspheres had a high encapsulation efficiency (up to 62%) tested by high performance liquid chromatography with a photo diode array. The dry microspheres were characterized by a scanning electron microscope, X-ray diffraction measurement, dynamic thermogravimetric analysis and Fourier transform infrared spectral analysis. The results of characterization showed that the microspheres had good thermal stability (decomposition temperature of 236°C), stable and temperature independent release properties (release time of more than 40 d). Compared to direct dosing of LA, LA sustained-released microspheres could inhibit Microcystis aeruginosa growth to the non-growth state. The results of this study suggested that the LA sustained-release microspheres may be a potential candidate for algal inhibition. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Recent advances in polymeric microspheres for parenteral drug delivery--part 1.

    Science.gov (United States)

    Mao, Shirui; Guo, Chunqiang; Shi, Yi; Li, Luk Chiu

    2012-09-01

    Polymeric microspheres have been established as a valuable parenteral drug delivery system for sustained release of therapeutic agents via subcutaneous or intramuscular injection. Biodegradable polymers which are either synthetic or from natural sources are reviewed with respect to recent advances in exploring their applications for microsphere fabrications. New information on the impact of formulation variables on the properties of microspheres formed by an emulsion method was also presented. The characterization of microspheres using advanced physical analytical techniques was also reviewed and the utilization of the information in assessing in vivo performance of the product was also highlighted. The broad clinical use of microspheres for delivery of therapeutic agents in particular biologics such as proteins has not been realized commercially. The limited availability of biodegradable polymers with a long history of regulatory approval and the challenges in gaining regulatory approval of a new polymer have hindered the development of microspheres for parenteral drug delivery.

  1. Catawba nuclear station preoperational ALARA review

    International Nuclear Information System (INIS)

    Deal, W.P.

    1985-01-01

    This paper describes the particular emphasis placed on preoperational as los as reasonably achievable (ALARA) considerations at Duke Power's Catawba Nuclear Station. A strong station commitment to the ALARA philosophy, and review of existing capabilities, led to development of an aggressive two-part ALARA program. Capabilities consisted of sufficient numbers of available personnel, lengthy lead time during construction, a very detailed plastic model, and a sister plant of similar design. The program, as developed, consisted of a preoperational program, which looked at design and construction aspects of ALARA, and the operational program, dealing with the ALARA committee and operational problems. MAnagement's philosophy of holding everyone responsible for ALARA provided the motivation to organize the preoperational program to use that resource. The Health Physics group accepted responsibility for development, coordination, and reviewer training. The problem provided a base to build on as station personnel gained experience in their own crafts and radiation protection in general

  2. Pre-operative fasting guidelines: an update

    DEFF Research Database (Denmark)

    Søreide, E; Eriksson, L I; Hirlekar, G

    2005-01-01

    Liberal pre-operative fasting routines have been implemented in most countries. In general, clear fluids are allowed up to 2 h before anaesthesia, and light meals up to 6 h. The same recommendations apply for children and pregnant women not in labour. In children......Liberal pre-operative fasting routines have been implemented in most countries. In general, clear fluids are allowed up to 2 h before anaesthesia, and light meals up to 6 h. The same recommendations apply for children and pregnant women not in labour. In children...

  3. A general approach to mesoporous metal oxide microspheres loaded with noble metal nanoparticles

    KAUST Repository

    Jin, Zhao; Xiao, Manda; Bao, Zhihong; Wang, Peng; Wang, Jianfang

    2012-01-01

    Catalytic microspheres: A general approach is demonstrated for the facile preparation of mesoporous metal oxide microspheres loaded with noble metal nanoparticles (see TEM image in the picture). Among 18 oxide/noble metal catalysts, TiO 2/0.1 mol Pd microspheres showed the highest turnover frequency in NaBH 4 reduction of 4-nitrophenol (see picture). Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Microspheres of poly(ε-caprolactone) loaded Holmium-165: morphology and thermal degradation behavior

    International Nuclear Information System (INIS)

    Geraldes, Adriana Napoleao; Miyamoto, Douglas Massao; Lira, Raphael Arivar de; Osso Junior, Joao Alberto; Nascimento, Nanci; Azevedo, Mariangela de Burgos M. de

    2011-01-01

    Polycaprolactone (PCL), being one of the most important biocompatible and biodegradable aliphatic polyester, provides many potential biomedical. The preparation of biodegradable materials, polymer-based microspheres, is being developed by our group and the goal is to prepare and label with Ho-165 different polymer-based microspheres. The use of radionuclide-loaded microspheres is a promising treatment of liver malignancies. PCL microspheres can be loaded with holmium acetylacetonate (HoAcAc). PCL and PCL/HoAcAc microspheres were prepared by an emulsion solvent extraction/evaporation technique. The PCL/ HoAcAc microspheres were irradiated in a nuclear reactor IEA-R1 at IPEN/CNEN-SP to radionuclide activation. Gamma irradiation was performed at 25 and 50 kGy doses. The microspheres were evaluated by differential scanning calorimetry analysis (DSC), thermogravimetric analysis (TG), Fourier transformed infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and con focal laser scanning microscopy (CLSM). In the CLSM images were observed emission in 488 nm characteristic of holmium. The SEM surface image of PCL/HoAcAc microspheres showed more roughness than PCL microspheres. TG of PCL/HoAcAc microspheres showed a substantial weight loss above 200 degree C, indicating decomposition of HoAcAc. The residual weight indicates the presence of Ho 2 O 3 . Gamma irradiation at 25 and 50 kGy doses had no effect on the PCL/HoAcAc microspheres, which indicates that the chemical composition of the microspheres had not change. (author)

  5. Microspheres of poly({epsilon}-caprolactone) loaded Holmium-165: morphology and thermal degradation behavior

    Energy Technology Data Exchange (ETDEWEB)

    Geraldes, Adriana Napoleao; Miyamoto, Douglas Massao; Lira, Raphael Arivar de; Osso Junior, Joao Alberto; Nascimento, Nanci; Azevedo, Mariangela de Burgos M. de [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    Polycaprolactone (PCL), being one of the most important biocompatible and biodegradable aliphatic polyester, provides many potential biomedical. The preparation of biodegradable materials, polymer-based microspheres, is being developed by our group and the goal is to prepare and label with Ho-165 different polymer-based microspheres. The use of radionuclide-loaded microspheres is a promising treatment of liver malignancies. PCL microspheres can be loaded with holmium acetylacetonate (HoAcAc). PCL and PCL/HoAcAc microspheres were prepared by an emulsion solvent extraction/evaporation technique. The PCL/ HoAcAc microspheres were irradiated in a nuclear reactor IEA-R1 at IPEN/CNEN-SP to radionuclide activation. Gamma irradiation was performed at 25 and 50 kGy doses. The microspheres were evaluated by differential scanning calorimetry analysis (DSC), thermogravimetric analysis (TG), Fourier transformed infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and con focal laser scanning microscopy (CLSM). In the CLSM images were observed emission in 488 nm characteristic of holmium. The SEM surface image of PCL/HoAcAc microspheres showed more roughness than PCL microspheres. TG of PCL/HoAcAc microspheres showed a substantial weight loss above 200 degree C, indicating decomposition of HoAcAc. The residual weight indicates the presence of Ho{sub 2}O{sub 3}. Gamma irradiation at 25 and 50 kGy doses had no effect on the PCL/HoAcAc microspheres, which indicates that the chemical composition of the microspheres had not change. (author)

  6. A general approach to mesoporous metal oxide microspheres loaded with noble metal nanoparticles

    KAUST Repository

    Jin, Zhao

    2012-04-26

    Catalytic microspheres: A general approach is demonstrated for the facile preparation of mesoporous metal oxide microspheres loaded with noble metal nanoparticles (see TEM image in the picture). Among 18 oxide/noble metal catalysts, TiO 2/0.1 mol Pd microspheres showed the highest turnover frequency in NaBH 4 reduction of 4-nitrophenol (see picture). Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Preparation and characterization of composite microspheres for brachytherapy and hyperthermia treatment of cancer

    International Nuclear Information System (INIS)

    Zhao Di; Huang Wenhai; Rahaman, Mohamed N.; Day, Delbert E.; Wang Deping; Gu Yifei

    2012-01-01

    Composite microspheres were prepared by coating yttrium–aluminum–silicate (YAS) glass microspheres (20–30 μm) with a layer of Fe 3 O 4 nanoparticles and evaluated for potential use in brachytherapy and hyperthermia treatment of cancer. After neutron activation to form the β-emitting 90 Y radionuclide, the composite microspheres can be injected into a patient to destroy cancerous tumors; at the same time, the composite microspheres can generate heat upon application of a magnetic field to also destroy the tumors. The results showed that the composite microspheres were chemically durable when immersed in a simulated body fluid (SBF), with ∼ 0.25% weight loss and ∼ 3.2% yttrium dissolved into the SBF after 30 days at 37 °C. The composite microspheres also showed ferromagnetic properties as a result of the Fe 3 O 4 coating; when immersed in water at 20 °C (20 mg in 1 mL of water), the application of an alternating magnetic field produced a temperature increase from 20 °C to 38−46 °C depending on the thickness of the Fe 3 O 4 coating. The results indicate that these composite microspheres have promising potential in combined brachytherapy and hyperthermia treatment of cancerous tumors. - Highlights: ► Composite microspheres for brachytherapy and hyperthermia treatment of cancer. ► Fe 3 O 4 nanoparticles coated on the yttrium–aluminum–silicate glass microspheres. ► Microspheres are chemically stable in SBF. ► Microspheres can generate heat for hyperthermia under an alternating magnetic field. ► Microspheres can emit β-rays for brachytherapy after neutron activation.

  8. Encapsulation of azithromycin into polymeric microspheres by reduced pressure-solvent evaporation method

    DEFF Research Database (Denmark)

    Li, Xiujuan; Chang, Si; Du, Guangsheng

    2012-01-01

    Azithromycin loaded microspheres with blends of poly-l-lactide and ploy-D,L-lactide-co-glycolide as matrices were prepared by the atmosphere-solvent evaporation (ASE) and reduced pressure-solvent evaporation (RSE) method. Both the X-ray diffraction spectra and DSC thermographs demonstrated...... characteristics and release profiles of microspheres. In conclusion, the overall improvement of microspheres in appearance, encapsulation efficiency and controlled drug release through the RSE method could be easily fulfilled under optimal preparation conditions....

  9. Polydimethylsiloxane microspheres with poly(methyl methacrylate) coating: Modelling, preparation, and characterization

    DEFF Research Database (Denmark)

    Ma, Baoguang; Hansen, Jens Henrik; Hvilsted, Søren

    2015-01-01

    functional PDMS microspheres were coated with poly(methyl methacrylate) (PMMA) by spin coating with different concentrations of PMMA solutions. The quality of the resulting PMMA shell is investigated using rheological measurements at 50 8C with a timesweep procedure. The results strongly suggest that PMMA-coated...... PDMS microspheres react around 20 times slower than the uncoated ones, and that the PMMA shell significantly hinders the reaction between the PDMS microsphere and cross-linker. Thus the thin PMMA shells are very efficient in protecting the reactive PDMS microspheres, since the PMMA shell forms...

  10. Method for selecting hollow microspheres for use in laser fusion targets

    Science.gov (United States)

    Farnum, Eugene H.; Fries, R. Jay; Havenhill, Jerry W.; Smith, Maurice Lee; Stoltz, Daniel L.

    1976-01-01

    Hollow microspheres having thin and very uniform wall thickness are useful as containers for the deuterium and tritium gas mixture used as a fuel in laser fusion targets. Hollow microspheres are commercially available; however, in commercial lots only a very small number meet the rigid requirements for use in laser fusion targets. Those meeting these requirements may be separated from the unsuitable ones by subjecting the commercial lot to size and density separations and then by subjecting those hollow microspheres thus separated to an external pressurization at which those which are aspherical or which have nonuniform walls are broken and separating the sound hollow microspheres from the broken ones.

  11. Controllable growth and photocatalytic activity of Cu{sub 2}O solid microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Hong; Zhang, Junying, E-mail: zjy@buaa.edu.cn; Wang, Mei

    2013-09-01

    Graphical abstract: - Highlights: • 3 μm uniform Cu{sub 2}O solid microspheres with abundant nanopores are achieved. • NH{sub 2}OH·HCl and SDS are main factors that manipulate morphologies of Cu{sub 2}O particles. • Surface features of microspheres influenced the photocatalytic activity of Cu{sub 2}O. • Microspheres are transforming to polyhedrons with extended holding time. - Abstract: A series of Cu{sub 2}O solid microspheres with different surface features were prepared and their photocatalytic activities were studied. The experiment conditions were investigated and the formation mechanism was explored systematically. It was found that varying the amounts of NH{sub 2}OH·HCl reductant in alkaline solutions changed the reaction process and thus altered the surface features of Cu{sub 2}O microspheres. Sodium dodecyl sulfate (SDS) surfactant, introduced as a morphology directing agent, caused the nuclei aggregation and growth process of Cu{sub 2}O solid microspheres by precisely realizing the opposite charges’ directional attraction. This SDS-mediated method can be readily extended to synthesizing solid microspheres of other metal oxides. Meanwhile, it was found that Cu{sub 2}O solid microspheres with abundant nanopores on the surface showed much higher efficient catalytic activity for decoloring methyl orange (MO) aqueous solution than with other surface features under visible light irradiation. Furthermore, we found that prolonging the holding time made Cu{sub 2}O microspheres transform to polyhedrons.

  12. Study on Magnetic Responsibility of Rare Earth Ferrite/Polyacrylamide Magnetic Microsphere

    Institute of Scientific and Technical Information of China (English)

    Zhang Ming; Wang Zhifeng; Zhang Hong; Dai Shaojun; Qiu Guanming; Okamoto Hiroshi

    2005-01-01

    In inverse microemulsion, rare earth ferrite/polyacrylamide magnetic microsphere were prepared and their magnetic responsibility were studied by magnetic balance. Results indicate that the magnetic responsibility of microsphere relates to magnetic moment of rare earth ion, and it can be improved by the addition of dysprosium ion of high magnetic moment. Dysprosium content has an effect on magnetic responsibility of dysprosium ferrite/polyacrylamide magnetic microsphere. The microsphere displays strong magnetic responsibility when the molar ratio of Dy3+/iron is 0.20.

  13. Preparation of chitosan/nano hydroxyapatite organic-inorganic hybrid microspheres for bone repair.

    Science.gov (United States)

    Chen, Jingdi; Pan, Panpan; Zhang, Yujue; Zhong, Shengnan; Zhang, Qiqing

    2015-10-01

    In this work, we encapsulated icariin (ICA) into chitosan (CS)/nano hydroxyapatite (nHAP) composite microspheres to form organic-inorganic hybrid microspheres for drug delivery carrier. The composition and morphology of composite microspheres were characterized by X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM) and differential scanning calorimetry- thermogravimetric analysis (DSC-TGA). Moreover, we further studied the performance of swelling properties, degradation properties and drug release behavior of the microspheres. ICA, the extract of traditional Chinese medicine-epimedium, was combined to study drug release properties of the microspheres. ICA loaded microspheres take on a sustained release behavior, which can be not only ascribed to electrostatic interaction between reactive negative hydroxyl (OH) of ICA and positive amine groups (NH₂) of CS, but also depended on the homogeneous dispersion of HAP nanoparticles inside CS organic matrix. In addition, the adhesion and morphology of osteoblasts were detected by inverted fluorescence microscopy. The biocompatibility of CS/nHAP/ICA microspheres was evaluated by the MTT cytotoxicity assay, Hoechst 33258 and PI fluorescence staining. These studies demonstrate that composite microspheres provide a suitable microenvironment for osteoblast attachment and proliferation. It can be speculated that the ICA loaded CS-based organic-inorganic hybrid microspheres might have potential applications in drug delivery systems. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. INVESTIGATION OF DRUG RELEASE FROM BIODEGRADABLE PLG MICROSPHERES: EXPERIMENT AND THEORY

    Energy Technology Data Exchange (ETDEWEB)

    ANDREWS, MALCOLM J. [Los Alamos National Laboratory; BERCHANE, NADER S. [Los Alamos National Laboratory; CARSON, KENNETH H. [Los Alamos National Laboratory; RICE-FICHT, ALLISON C. [Los Alamos National Laboratory

    2007-01-30

    Piroxicam containing PLG microspheres having different size distributions were fabricated, and in vitro release kinetics were determined for each preparation. Based on the experimental results, a suitable mathematical theory has been developed that incorporates the effect of microsphere size distribution and polymer degradation on drug release. We show from in vitro release experiments that microsphere size has a significant effect on drug release rate. The initial release rate decreased with an increase in microsphere size. In addition, the release profile changed from first order to concave-upward (sigmoidal) as the system size was increased. The mathematical model gave a good fit to the experimental release data.

  15. Recent advances in Pt coating of microspheres by a batch magnetron sputtering process

    International Nuclear Information System (INIS)

    Hsieh, E.J.; Meyer, S.F.

    1980-01-01

    Some proposed inertial confinement fusion targets require high-Z, high density metal coatings on glass microspheres. Platinum, which satisfies the high-Z and density requirements, can be coated onto microspheres with a batch magnetron sputtering process incorporating oxygen as a dopant gas to prevent the microspheres from sticking. This paper outlines recent progress in three areas: First, the coating process has been improved; second, the oxygen content and resistivity of the oxygen doped platinum films are analyzed; and third, the roles oxygen may play in reducing microsphere sticking during sputtering are discussed in regard to cold welding, Van der Waals bonding, electrostatic sticking, and sintering

  16. Effect of various polymers concentrations on physicochemical properties of floating microspheres.

    Science.gov (United States)

    Jagtap, Y M; Bhujbal, R K; Ranade, A N; Ranpise, N S

    2012-11-01

    Floating microspheres have emerged as a potential candidate for gastroretentive drug delivery system. For developing a desired intragastric floatation system employing these microspheres, it is necessary to select an appropriate balance between buoyancy and drug releasing rate. These properties mainly depend on the polymers used in the formulation of the microspheres. Hence it is necessory to study the effect of these polymer concentrations on the various physicochemical properties of the microspheres. Floating microspheres were prepared by emulsion solvent evaporation technique utilising different polymers such as ethyl cellulose, Eudragit(®) RS and Eudragit(®) RL by dissolving them in a mixture of dichloromethane and methanol. Release modifiers studied were hydroxypropyl methylcellulose K4M, hydroxypropyl methylcellulose E50 LV and Eudragit(®) EPO. Prepared microspheres were analysed for particle size, surface morphology, entrapment efficiency, buoyancy, differential scanning calorimetry and in-vitro drug release. Ethyl cellulose and Eudragit(®) EPO resulted microspheres with high percentage yield, excellent spherical shape but had very less buoyancies with a high cumulative drug release. Ethyl cellulose microspheres prepared using hydroxypropyl methylcellulose K4M showed more sustained drug release and high buoyancies than that of the microspheres formulated with the hydroxypropyl methylcellulose E50 LV. Amongst these hydroxypropyl methylcellulose E50 LV showed good balance between buoyancy and the drug release.

  17. Synthesis and characterization of magnesium gluconate contained poly(lactic-co-glycolic acid)/chitosan microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, Shekh M. [Department of Chemical, Biological and Bioengineering, North Carolina A& T State University, 1601 East Market Street, Greensboro, NC 27411 (United States); NSF Engineering Research Center for Revolutionizing Metallic Biomaterials, North Carolina A& T State University, Greensboro, NC 27411 (United States); Mahoney, Christopher [Department of Bioengineering, University of Pittsburgh, 4200 Fifth Avenue, Pittsburgh, PA 15250 (United States); Sankar, Jagannathan [NSF Engineering Research Center for Revolutionizing Metallic Biomaterials, North Carolina A& T State University, Greensboro, NC 27411 (United States); Department of Mechanical Engineering, North Carolina A& T State University, 1601 East Market Street, Greensboro, NC 27411 (United States); Marra, Kacey G. [NSF Engineering Research Center for Revolutionizing Metallic Biomaterials, North Carolina A& T State University, Greensboro, NC 27411 (United States); Department of Bioengineering, University of Pittsburgh, 4200 Fifth Avenue, Pittsburgh, PA 15250 (United States); Department of Plastic Surgery, University of Pittsburgh, 200 Lothrop Street, Pittsburgh, PA 15250 (United States); McGowan Institute for Regenerative Medicine, University of Pittsburgh, 450 Technology Drive, Pittsburgh, PA 15250 (United States); Bhattarai, Narayan, E-mail: nbhattar@ncat.edu [Department of Chemical, Biological and Bioengineering, North Carolina A& T State University, 1601 East Market Street, Greensboro, NC 27411 (United States); NSF Engineering Research Center for Revolutionizing Metallic Biomaterials, North Carolina A& T State University, Greensboro, NC 27411 (United States)

    2016-01-15

    Graphical abstract: - Highlights: • Magnesium gluconate contained PLGA/chitosan microspheres were fabricated. • In vitro release of magnesium ions was performed using Xylidyl Blue assay. • Chitosan coated PLGA can significantly control the release of magnesium ions. • Cellular compatibility was tested using adipose-derived stem cells and PC12 cells. • The cells encounter acceptably low levels of damage in contact with microspheres. - Abstract: The goal of this study was to fabricate and investigate the chitosan coated poly(lactic-co-glycolic acid) (PLGA) microspheres for the development of controlled release magnesium delivery system. PLGA based microspheres are ideal vehicles for many controlled release drug delivery applications. Chitosan is a naturally occurring biodegradable and biocompatible polysaccharide, which can coat the surface of PLGA to alter the release of drugs. Magnesium gluconate (MgG) was encapsulated in the PLGA and PLGA/chitosan microspheres by utilizing the double emulsion solvent evaporation technique for controlled release study. The microspheres were tested with respect to several physicochemical and biological properties, including morphology, chemical structure, chitosan adsorption efficiency, magnesium encapsulation efficiency, in vitro release of magnesium ions, and cellular compatibility using both human adipose-derived stem cells (ASCs) and PC12 cells. Chitosan coated PLGA microspheres can significantly control the release of magnesium ions compared to uncoated PLGA microspheres. Both coated and uncoated microspheres showed good cellular compatibility.

  18. Methanol and ethanol electrooxidation on Pt and Pd supported on carbon microspheres in alkaline media

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Changwei; Cheng, Liqiang; Liu, Yingliang [Department of Chemistry and Institute of Nanochemistry, Jinan University, Guangzhou 510632 (China); Shen, Peikang [State Key Laboratory of Optoelectronic Materials and Technologies, School of Physics and Engineering, Sun Yat-Sen University, Guangzhou 510275 (China)

    2007-05-15

    Noble metal (Pt, Pd) electrocatalysts supported on carbon microspheres (CMS) are used for methanol and ethanol oxidation in alkaline media. The results show that noble metal electrocatalysts supported on carbon microspheres give better performance than that supported on carbon black. It is well known that palladium is not a good electrocatalyst for methanol oxidation, but it shows excellently higher activity and better steady-state electrolysis than Pt for ethanol electrooxidation in alkaline media. The results show a synergistic effect by the interaction between Pd and carbon microspheres. The Pd supported on carbon microspheres in this paper possesses excellent electrocatalytic properties and may be of great potential in direct ethanol fuel cells. (author)

  19. Study of neutron absorbing microspheres in research reactors - Neutronic analyse

    International Nuclear Information System (INIS)

    Gana Watkins, Ignacio A.; Prado, Miguel O.; Mazufri, Claudio; Tunon, Juan M

    2012-01-01

    Now-a-days, it is increasingly common for nuclear power plants, as well as research reactors, to be designed and built with an alternative safety system aside from control rods. The acids and/or salts in solution injection systems is most frequently used. However, these systems present several implementation and operation problems due to the physical and chemical properties of the used compounds. After analyzing these drawbacks, we developed a new alternative safety system that contains the absorbing element isolated from the aqueous medium. In this context, it's proposed the use of aluminum borosilicate microspheres. The current paper presents erosion wear experiments to determine under which conditions microspheres can be considered as a potential component of a secondary shut down system in a nuclear facility (author)

  20. Carbon microspheres as ball bearings in aqueous-based lubrication.

    Science.gov (United States)

    St Dennis, J E; Jin, Kejia; John, Vijay T; Pesika, Noshir S

    2011-07-01

    We present an exploratory study on a suspension of uniform carbon microspheres as a new class of aqueous-based lubricants. The surfactant-functionalized carbon microspheres (∼0.1 wt %) employ a rolling mechanism similar to ball bearings to provide low friction coefficients (μ ≈ 0.03) and minimize surface wear in shear experiments between various surfaces, even at high loads and high contact pressures. The size range, high monodispersity, and large yield stress of the C(μsphere), as well as the minimal environmental impact, are all desirable characteristics for the use of a C(μsphere)-SDS suspension as an alternative to oil-based lubricants in compatible devices and machinery.

  1. Polyacrylate microspheres composite for all-solid-state reference electrodes.

    Science.gov (United States)

    Kisiel, Anna; Donten, Mikołaj; Mieczkowski, Józef; Rius-Ruiz, F Xavier; Maksymiuk, Krzysztof; Michalska, Agata

    2010-09-01

    A novel concept is proposed for the encapsulation of components within polyacrylate microspheres, prior to their incorporation into a membrane phase. Thus finer and better controlled dispersion of heterogeneous membrane components can be achieved. This concept was verified by using a poly(n-butyl acrylate) membrane-based reference electrode as an example. In this example the proper dispersion of solid constituents of the heterogeneous membrane and prevention of their leakage are both of primary importance. Potassium chloride-loaded poly(n-butyl acrylate) microspheres were prepared and then left in contact with silver nitrate to convert some of the KCl into AgCl. The material obtained was introduced into a poly(n-butyl acrylate) membrane. The reference electrode membranes obtained in this way were characterized with much more stable potential (both in different electrolytes and over time) compared with electrodes prepared by the direct introduction of KCl and AgCl to the membrane.

  2. Coherent inflation for large quantum superpositions of levitated microspheres

    Science.gov (United States)

    Romero-Isart, Oriol

    2017-12-01

    We show that coherent inflation (CI), namely quantum dynamics generated by inverted conservative potentials acting on the center of mass of a massive object, is an enabling tool to prepare large spatial quantum superpositions in a double-slit experiment. Combined with cryogenic, extreme high vacuum, and low-vibration environments, we argue that it is experimentally feasible to exploit CI to prepare the center of mass of a micrometer-sized object in a spatial quantum superposition comparable to its size. In such a hitherto unexplored parameter regime gravitationally-induced decoherence could be unambiguously falsified. We present a protocol to implement CI in a double-slit experiment by letting a levitated microsphere traverse a static potential landscape. Such a protocol could be experimentally implemented with an all-magnetic scheme using superconducting microspheres.

  3. Synthesis and characterization of porous microspheres bearing pyrrolidone units

    Energy Technology Data Exchange (ETDEWEB)

    Maciejewska, M., E-mail: mmacieje@umcs.pl; Kołodyńska, D.

    2015-01-15

    Porous microspheres of glycydyl methacrylate (GMA) cross-linked with trimethylolpropane trimethacrylate (TRIM) were prepared with toluene as porogen by suspension-emulsion polymerization. With increasing molar ratio of the functional monomer to cross-linker, the epoxy group content increases significantly whereas the parameters of porous structure (specific surface area and total pore volume) decreases. In order to obtain adsorbents bearing functional groups the porous methacrylate network was modified by subsequent reaction with pyrrolidone. The materials were studied using elemental analysis, infrared spectroscopy, atomic force microscopy (AFM), attenuated total reflection (ATR) spectroscopy, Raman spectroscopy, thermal gravimetry. Additionally, polymers sorption capacity towards Cu(II) was investigated. - Highlights: • Porous microspheres with reactive epoxy group were synthesized. • Highly developed porous structure was created. • Pyrrolidone units were incorporated during ring–opening reaction. • Polymers sorption capacity towards Cu (II) was investigated.

  4. Chitosan magnetic microspheres for technological applications: Preparation and characterization

    International Nuclear Information System (INIS)

    Podzus, P.E.; Daraio, M.E.; Jacobo, S.E.

    2009-01-01

    One of the major applications of chitosan and its many derivatives are based on its ability to bind strongly heavy and toxic metal ions. In this study chitosan magnetic microspheres have been synthesized. Acetic acid (1%w/v) solution was used as solvent for the chitosan polymer solution (2%w/v) where magnetite nanoparticles were suspended in order to obtain a stable ferrofluid. Glutaraldehyde was used as cross-linker. The magnetic characteristic of these materials allows an easy removal after use if is necessary. The morphological characterization of the microspheres shows that they can be produced in the size range 800-1100 μm. The adsorption of Cu(II) onto chitosan-magnetite nanoparticles was studied in batch system. A second-order kinetic model was used to fit the kinetic data, leading to an equilibrium adsorption capacity of 19 mg Cu/g chitosan.

  5. PREPARATION AND CHARACTERIZATION OF POROUS WALLED HOLLOW GLASS MICROSPHERES

    Energy Technology Data Exchange (ETDEWEB)

    Raszewski, F; Erich Hansen, E; Ray Schumacher, R; David Peeler, D

    2008-04-21

    Porous-walled hollow glass microspheres (PWHGMs) of a modified alkali borosilicate composition have been successfully fabricated by combining the technology of producing hollow glass microspheres (HGMs) with the knowledge associated with porous glasses. HGMs are first formed by a powder glass--flame process, which are then transformed to PWHGMs by heat treatment and subsequent treatment in acid. Pore diameter and pore volume are most influenced by heat treatment temperature. Pore diameter is increased by a factor of 10 when samples are heat treated prior to acid leaching; 100 {angstrom} in non-heat treated samples to 1000 {angstrom} in samples heat treated at 600 C for 8 hours. As heat treatment time is increased from 8 hours to 24 hours there is a slight shift increase in pore diameter and little or no change in pore volume.

  6. Onion-like microspheres with tricomponent from gelable triblock copolymers.

    Science.gov (United States)

    Zhang, Ke; Gao, Lei; Chen, Yongming; Yang, Zhenzhong

    2010-06-01

    Onion-like functional microspheres with three alternate layers were obtained by aerosol-assisted self-assembly of a functional block copolymer, poly(3-(triethoxysilyl)propyl methacrylate)-block-polystyrene-block-poly(2-vinylpyridine) (PTEPM-b-PS-b-P2VP). Through self-gelation reaction occurred in the PTEPM layers, organic/inorganic hybrid functional spheres with highly ordered concentric curved lamellar structure were prepared. Using these hybrid onion-like microspheres as templates, gold ions were entrapped into the P2VP layers and then gold nanoparticles located in each P2VP layers were formed by a reduction. By dispersing in acidic water, the onion-like polymeric spheres were broken and, as a result, sandwich-like nanoplates with curved morphology were obtained. Copyright © 2010 Elsevier Inc. All rights reserved.

  7. Treatment of metastasis localizations by intratumoral injection of radionuclide microsphere

    International Nuclear Information System (INIS)

    Tuo Peiyu; Pang Yan; Zhu Dianqing; Chang Keli; Zhu Yanjia

    2001-01-01

    Objective: To evaluate the therapeutic effects of radionuclide-labeled microsphere by intratumoral injection into 18 patients with superficial metastasis tumor for treatment. Methods: 18 patients with superficial metastasis were treated with radionuclide-labeled microsphere ( 90 Y-GTMS and 32 P-GTMS) by multi-point intratumoral injection. Each injection dose was 11.1-18.5 MBq/g (tumor). Results: 1 patient was relieved completely, 9 were relieved partly, 5 were improved and 3 kept stable. The total rate of relief and virtual value were 55.6% and 83.3% respectively. Conclusion: Topical treatment by using radionuclide may help diminish the tumor, control its progress and ease the symptoms. Thus it can be used as a supplement of routine treatment of tumors and it should do some work in therapy of malignant tumors in late stages

  8. Preoperational test report, primary ventilation system

    International Nuclear Information System (INIS)

    Clifton, F.T.

    1997-01-01

    This represents a preoperational test report for Primary Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides vapor space filtered venting of tanks AY101, AY102, AZ101, AZ102. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System

  9. Preoperative biliary drainage for pancreatic cancer

    NARCIS (Netherlands)

    van Heek, N. T.; Busch, O. R.; van Gulik, T. M.; Gouma, D. J.

    2014-01-01

    This review is to summarize the current knowledge about preoperative biliary drainage (PBD) in patients with biliary obstruction caused by pancreatic cancer. Most patients with pancreatic carcinoma (85%) will present with obstructive jaundice. The presence of toxic substances as bilirubin and bile

  10. PREOPERATIVE ENDOSCOPIC MARKING OF UNPALPABLE COLONIC TUMORS

    Directory of Open Access Journals (Sweden)

    A. L. Goncharov

    2013-01-01

    Full Text Available The identification of small colon lesions is one of the major problems in laparoscopic colonic resection.Research objective: to develop a technique of visualization of small tumors of a colon by preoperative endoscopic marking of a tumor.Materials and methods. In one day prior to operation to the patient after bowel preparation the colonoscopy is carried out. In the planned point near tumor on antimesentery edge the submucous infiltration of marking solution (Micky Sharpz blue tattoo pigment, UK is made. The volume of entered solution of 1–3 ml. In only 5 months of use of a technique preoperative marking to 14 patients with small (the size of 1–3 cm malignant tumors of the left colon is performed.Results. The tattoo mark was well visualized by during operation at 13 of 14 patients. In all cases we recorded no complications. Time of operation with preoperative marking averaged 108 min, that is significantly less in comparison with average time of operation with an intra-operative colonoscopy – 155 min (р < 0.001.Conclusions. The first experience of preoperative endoscopic marking of non palpable small tumors of a colon is encouraging. Performance of a technique wasn't accompanied by complications and allowed to reduce significantly time of operation and to simplify conditions of performance of operation.

  11. Preoperative exercise training to improve postoperative outcomes

    NARCIS (Netherlands)

    Valkenet, K.

    2017-01-01

    It is common knowledge that better preoperative physical fitness is associated with better postoperative outcomes. However, as a result of aging of the population and improved surgical and anaesthesia techniques, the proportion of frail patients with decreased physical fitness levels undergoing

  12. Interdisciplinary preoperative patient education in cardiac surgery.

    NARCIS (Netherlands)

    Weert, J. van; Dulmen, S. van; Bar, P.; Venus, E.

    2003-01-01

    Patient education in cardiac surgery is complicated by the fact that cardiac surgery patients meet a lot of different health care providers. Little is known about education processes in terms of interdisciplinary tuning. In this study, complete series of consecutive preoperative consultations of 51

  13. Preoperative diagnosis of malignant hyperthermia | Brand ...

    African Journals Online (AJOL)

    Southern African Journal of Anaesthesia and Analgesia. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 9, No 1 (2003) >. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register. Preoperative diagnosis of malignant ...

  14. Preoperational test report, primary ventilation system

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-11-04

    This represents a preoperational test report for Primary Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides vapor space filtered venting of tanks AY101, AY102, AZ101, AZ102. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  15. Ampullopancreatic carcinoma: preoperative TNM classification with endosonography

    NARCIS (Netherlands)

    Tio, T. L.; Tytgat, G. N.; Cikot, R. J.; Houthoff, H. J.; Sars, P. R.

    1990-01-01

    Endosonography (ES) was used for the preoperative TNM (1987) staging of tumors in 43 patients with pancreatic cancer and 24 patients with ampullary carcinomas. These results were correlated with the histologic findings of resected specimens. Early-stage tumors could be distinguished from advanced

  16. Preoperative screening: value of previous tests.

    Science.gov (United States)

    Macpherson, D S; Snow, R; Lofgren, R P

    1990-12-15

    To determine the frequency of tests done in the year before elective surgery that might substitute for preoperative screening tests and to determine the frequency of test results that change from a normal value to a value likely to alter perioperative management. Retrospective cohort analysis of computerized laboratory data (complete blood count, sodium, potassium, and creatinine levels, prothrombin time, and partial thromboplastin time). Urban tertiary care Veterans Affairs Hospital. Consecutive sample of 1109 patients who had elective surgery in 1988. At admission, 7549 preoperative tests were done, 47% of which duplicated tests performed in the previous year. Of 3096 previous results that were normal as defined by hospital reference range and done closest to the time of but before admission (median interval, 2 months), 13 (0.4%; 95% CI, 0.2% to 0.7%), repeat values were outside a range considered acceptable for surgery. Most of the abnormalities were predictable from the patient's history, and most were not noted in the medical record. Of 461 previous tests that were abnormal, 78 (17%; CI, 13% to 20%) repeat values at admission were outside a range considered acceptable for surgery (P less than 0.001, frequency of clinically important abnormalities of patients with normal previous results with those with abnormal previous results). Physicians evaluating patients preoperatively could safely substitute the previous test results analyzed in this study for preoperative screening tests if the previous tests are normal and no obvious indication for retesting is present.

  17. Preoperational test report, vent building ventilation system

    International Nuclear Information System (INIS)

    Clifton, F.T.

    1997-01-01

    This represents a preoperational test report for Vent Building Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides Heating, Ventilation, and Air Conditioning (HVAC) for the W-030 Ventilation Building. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System

  18. Preoperative evaluation : risk management and implementation aspects

    NARCIS (Netherlands)

    Klei, W.A. van

    2002-01-01

    In preoperative risk management the anesthesiologist uses diagnostic information to estimate the probability of outcomes and to decide on the anesthetic strategy in a particular patient. The aim of this thesis was explore to what extent simple patient characteristics, particularly obtained from

  19. Microsphere imaging with confocal microscopy and two photon microscopy

    International Nuclear Information System (INIS)

    Chun, Hyung Su; An, Kyung Won; Lee, Jai Hyung

    2002-01-01

    We have acquired images of polystyrene and fused-silica microsphere by using conventional optical microscopy, confocal microscopy and two-photon microscopy, and performed comparative analysis of these images. Different from conventional optical microscopy, confocal and two-photon microscopy had good optical sectioning capability. In addition, confocal microscopy and two-photon microscopy had better lateral resolution than conventional optical microscopy. These results are attributed to confocality and nonlinearity of confocal microscopy and two photon microscopy, respectively.

  20. Resin 90Y microsphere activity measurements for liver brachytherapy

    International Nuclear Information System (INIS)

    Dezarn, William A.; Kennedy, Andrew S.

    2007-01-01

    The measurement of the radioactivity administered to the patient is one of the major components of 90 Y microsphere liver brachytherapy. The activity of 90 Y microspheres in a glass delivery vial was measured in a dose calibrator. The calibration value to use for 90 Y in the dose calibrator was verified using an activity calibration standard provided by the microsphere manufacturer. This method allowed for the determination of a consistent, reproducible local activity standard. Additional measurements were made to determine some of the factors that could affect activity measurement. The axial response of the dose calibrator was determined by the ratio of activity measurements at the bottom and center of the dose calibrator. The axial response was 0.964 for a glass shipping vial, 1.001 for a glass V-vial, and 0.988 for a polycarbonate V-vial. Comparisons between activity measurements in the dose calibrator and those using a radiation survey meter were found to agree within 10%. It was determined that the dose calibrator method was superior to the survey meter method because the former allowed better defined measurement geometry and traceability of the activity standard back to the manufacturer. Part of the preparation of resin 90 Y microspheres for patient delivery is to draw out a predetermined activity from a shipping vial and place it into a V-vial for delivery to the patient. If the drawn activity was placed in a glass V-vial, the activity measured in the dose calibrator with a glass V-vial was 4% higher than the drawn activity from the shipping vial standard. If the drawn activity was placed in a polycarbonate V-vial, the activity measured in the dose calibrator with a polycarbonate V-vial activity was 20% higher than the drawn activity from the shipping vial standard. Careful characterization of the local activity measurement standard is recommended instead of simply accepting the calibration value of the dose calibrator manufacturer

  1. The measurement of radioactive microspheres in biological samples

    International Nuclear Information System (INIS)

    Mernagh, J.R.; Spiers, E.W.; Adiseshiah, M.

    1976-01-01

    Measurements of the distribution of radioactive microspheres are used in investigations of regional coronary blood flow, but the size and shape of the heart varies for different test animals, and the organ is frequently divided into smaller pieces for studies of regional perfusion. Errors are introduced by variations in the distribution of the radioactive source and the amount of Compton scatter in different samples. A technique has therefore been developed to allow the counting of these tissue samples in their original form, and correction factors have been derived to inter-relate the various counting geometries thus encountered. Dogs were injected with microspheres labelled with 141 Ce, 51 Cr or 85 Sr. The tissue samples did not require remodelling to fit a standard container, and allowance was made for the inhomogeneous distribution in the blood samples. The activities in the centrifuged blood samples were correlated with those from the tissue samples by a calibration procedure involving comparisons of the counts from samples of microspheres embedded in sachets of gelatine, and similar samples mixed with blood and then centrifuged. The calibration data have indicated that 51 Cr behaves anomalously, and its use as a label for microspheres may introduce unwarranted errors. A plane cylindrical 10 x 20 cm NaI detector was used, and a 'worst case' correction of 20% was found to be necessary for geometry effects. The accuracy of this method of correlating different geometries was tested by remodelling the same tissue sample into different sizes and comparing the results, and the validity of the technique was supported by agreement of the final results with previously published data. (U.K.)

  2. Immunomagnetic sulfonated hypercrosslinked polystyrene microspheres for electrochemical detection of proteins

    Czech Academy of Sciences Publication Activity Database

    Šálek, Petr; Korecká, L.; Horák, Daniel; Petrovský, Eduard; Kovářová, Jana; Metelka, R.; Čadková, M.; Bílková, Z.

    2011-01-01

    Roč. 21, č. 38 (2011), s. 14783-14792 ISSN 0959-9428 R&D Projects: GA ČR GA203/09/0857; GA ČR GA203/09/1242 Institutional research plan: CEZ:AV0Z40500505; CEZ:AV0Z30120515 Keywords : styrene * divinylbenzene * microspheres Subject RIV: CD - Macromolecular Chemistry Impact factor: 5.968, year: 2011

  3. Magnetic poly(glycidyl methacrylate) microspheres for protein capture

    Czech Academy of Sciences Publication Activity Database

    Koubková, Jana; Müller, P.; Hlídková, Helena; Plichta, Zdeněk; Proks, Vladimír; Vojtěšek, B.; Horák, Daniel

    2014-01-01

    Roč. 31, č. 5 (2014), s. 482-491 ISSN 1871-6784 R&D Projects: GA ČR GCP207/12/J013; GA MŠk 7E12053 EU Projects: European Commission(XE) 246513 - NADINE Institutional support: RVO:61389013 Keywords : glycidyl methacrylate * microspheres * protein p53 Subject RIV: CD - Macromolecular Chemistry Impact factor: 2.898, year: 2014

  4. Porous spherical shells and microspheres by electrodispersion precipitation

    International Nuclear Information System (INIS)

    Harris, M.T.; Sisson, W.G.; Basaran, O.A.; Hayes, S.M.; Bobrowski, S.J.

    1994-01-01

    The ability to reproduce the synthesis of dense- and porous-microspheres and micron-sized spherical shells is very important in (a) the development of ceramics for structural, electronic, catalyst and thermal applications; and (b) the encapsulation of products for controlled-release of drugs, flavors and perfumes, and inks and dyes, and the protection of light-sensitive components and mechanical support of fragile materials. Larger metallic- and ceramic-spherical shells have been used in inertial confinement fusion (ICF) experiments and as catalyst supports. The current paper will focus on a recent technique that has been developed for synthesizing ceramic microspheres and micro-shells. Pulsed electric fields have been used to enhance the dispersion of aqueous metal (Zr and Al) salt solutions from a nozzle and into a nonconducting liquid continuous phase that is immiscible with the aqueous phase. The diameter of the resulting microdroplets ranged in size from approximately 0.1 to 10 μm. Precipitation of hydrous metal oxides occurred as ammonia, which was dissolved in varying amounts in the continuous phase, diffused into the aqueous microdroplets. Spherical shells were formed at higher ammonia concentrations and microspheres were produced at lower ammonia concentrations. Upon drying, dimples appeared in the particles that were synthesized at higher ammonia concentrations. The latter result accords with the well known fact that under certain conditions spherical shells collapse when a fluid is extracted from the core of the particle. No dimples were observed in the microspheres that were produced at lower ammonia concentrations. Analog X-ray dot maps for aluminum and zirconium were done to determine the spatial distribution of each metal in the particles

  5. Power output and efficiency of beta-emitting microspheres

    International Nuclear Information System (INIS)

    Cheneler, David; Ward, Michael

    2015-01-01

    Current standard methods to calculate the dose of radiation emitted during medical applications by beta-minus emitting microspheres rely on an over-simplistic formalism. This formalism is a function of the average activity of the radioisotope used and the physiological dimensions of the patient only. It neglects the variation in energy of the emitted beta particle due to self-attenuation, or self-absorption, effects related to the finite size of the sphere. Here it is assumed the sphere is comprised of a pure radioisotope with beta particles being emitted isotropically throughout the material. The full initial possible kinetic energy distribution of a beta particle is taken into account as well as the energy losses due to scattering by other atoms in the microsphere and bremsstrahlung radiation. By combining Longmire’s theory of the mean forward range of charged particles and the Rayleigh distribution to take into account the statistical nature of scattering and energy straggling, the linear attenuation, or self-absorption, coefficient for beta-emitting radioisotopes has been deduced. By analogy with gamma radiation transport in spheres, this result was used to calculate the rate of energy emitted by a beta-emitting microsphere and its efficiency. Comparisons to standard point dose kernel formulations generated using Monte Carlo data show the efficacy of the proposed method. Yttrium-90 is used as a specific example throughout, as a medically significant radioisotope, frequently used in radiation therapy for treating cancer. - Highlights: • Range-energy relationship for the beta particles in yttrium-90 is calculated. • Formalism for the semi-analytical calculation of self-absorption coefficients. • Energy-dependent self-absorption coefficient calculated for yttrium-90. • Flux rate of beta particles from a self-attenuating radioactive sphere is shown. • The efficiency of beta particle emitting radioactive microspheres is calculated

  6. Sustained release of simvastatin from hollow carbonated hydroxyapatite microspheres prepared by aspartic acid and sodium dodecyl sulfate.

    Science.gov (United States)

    Wang, Ke; Wang, Yinjing; Zhao, Xu; Li, Yi; Yang, Tao; Zhang, Xue; Wu, Xiaoguang

    2017-06-01

    Hollow carbonated hydroxyapatite (HCHAp) microspheres as simvastatin (SV) sustained-release vehicles were fabricated through a novel and simple one-step biomimetic strategy. Firstly, hollow CaCO 3 microspheres were precipitated through the reaction of CaCl 2 with Na 2 CO 3 in the presence of aspartic acid and sodium dodecyl sulfate. Then, the as-prepared hollow CaCO 3 microspheres were transformed into HCHAp microspheres with a controlled anion-exchange method. The HCHAp microspheres were 3-5μm with a shell thickness of 0.5-1μm and were constructed of short needle nanoparticles. The HCHAp microspheres were then loaded with SV, exhibiting excellent drug-loading capacity and sustained release properties. These results present a new material synthesis strategy for HCHAp microspheres and suggest that the as-prepared HCHAp microspheres are promising for applications in drug delivery. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Kefiran-alginate gel microspheres for oral delivery of ciprofloxacin.

    Science.gov (United States)

    Blandón, Lina M; Islan, German A; Castro, Guillermo R; Noseda, Miguel D; Thomaz-Soccol, Vanete; Soccol, Carlos R

    2016-09-01

    Ciprofloxacin is a broad-spectrum antibiotic associated with gastric and intestinal side effects after extended oral administration. Alginate is a biopolymer commonly employed in gel synthesis by ionotropic gelation, but unstable in the presence of biological metal-chelating compounds and/or under dried conditions. Kefiran is a microbial biopolymer able to form gels with the advantage of displaying antimicrobial activity. In the present study, kefiran-alginate gel microspheres were developed to encapsulate ciprofloxacin for antimicrobial controlled release and enhanced bactericidal effect against common pathogens. Scanning electron microscopy (SEM) analysis of the hybrid gel microspheres showed a spherical structure with a smoother surface compared to alginate gel matrices. In vitro release of ciprofloxacin from kefiran-alginate microspheres was less than 3.0% and 5.0% at pH 1.2 (stomach), and 5.0% and 25.0% at pH 7.4 (intestine) in 3 and 21h, respectively. Fourier transform infrared spectroscopy (FTIR) of ciprofloxacin-kefiran showed the displacement of typical bands of ciprofloxacin and kefiran, suggesting a cooperative interaction by hydrogen bridges between both molecules. Additionally, the thermal analysis of ciprofloxacin-kefiran showed a protective effect of the biopolymer against ciprofloxacin degradation at high temperatures. Finally, antimicrobial assays of Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa, Salmonella typhymurium, and Staphylococcus aureus demonstrated the synergic effect between ciprofloxacin and kefiran against the tested microorganisms. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Microspherical polyaniline/graphene nanocomposites for high performance supercapacitors

    Science.gov (United States)

    Cao, Hailiang; Zhou, Xufeng; Zhang, Yiming; Chen, Liang; Liu, Zhaoping

    2013-12-01

    Polyaniline/graphene nanocomposites with microspherical morphology and porous structure are prepared as electrode materials for supercapacitors. Using few-layer graphene obtained by liquid phase exfoliation of graphite as the raw material, porous graphene microspheres are produced by spray drying, and are then employed as the substrates for the growth of polyaniline nanowire arrays by in situ polymerization. In the composite, interconnected graphene sheets with few structural defects constitute a high-efficient conductive network to improve the electrical conductivity of polyaniline. Furthermore, the microspherical architecture prevents restacking of polyaniline/graphene composite nanosheets, thus facilitates fast diffusion of electrolytes. Consequently, the nanocomposite exhibits excellent electrochemical performance. A specific capacitance of 338 F g-1 is reached in 1 M H2SO4 at a scan rate of 20 mV s-1, and a high capacity retention rate of 87.4% after 10,000 cycles at a current density of 3 A g-1 can be achieved, which suggests that the polyaniline/graphene composite with such kind of 3D architecture is a promising electrode material for high-performance supercapacitors.

  9. Diclofenac salts, part 6: release from lipid microspheres.

    Science.gov (United States)

    Fini, Adamo; Cavallari, Cristina; Rabasco Alvarez, Antonio M; Rodriguez, Marisa Gonzalez

    2011-08-01

    The release of diclofenac (20%, w/w) was studied from lipidic solid dispersions using three different chemical forms (acid, sodium salt, and pyrrolidine ethanol salt) and two different lipid carriers (Compritol 888 ATO or Carnauba wax) either free or together with varying amounts (10%-30%, w/w) of stearic acid. Microspheres were prepared by ultrasound-assisted atomization of the molten dispersions and analyzed by scanning electron microscopy, differential scanning calorimetry, and hot stage microscopy. The effects of different formulations on the resulting drug release profiles as a function of pH were studied and the results were discussed. The formulation of the 18 systems and the chemical form of the drug were found to strongly affect the mode of the drug release. The solubility of the chemical forms in the lipid mixture is in the following order: pyrrolidine ethanol salt ≫ acid > sodium salt (according to the solubility parameters), and the nature of the systems thus obtained ranges from a matrix, for mutually soluble drug/carrier pairs, to a microcapsule, for pairs wherein mutual solubility is poor. Drug release from microspheres prepared by pure lipids was primarily controlled by diffusion, whereas the release from microspheres containing stearic acid was diffusion/erosion controlled at pH 7.4. Copyright © 2011 Wiley-Liss, Inc.

  10. Multiplex detection of plant pathogens using a microsphere immunoassay technology.

    Directory of Open Access Journals (Sweden)

    Ratthaphol Charlermroj

    Full Text Available Plant pathogens are a serious problem for seed export, plant disease control and plant quarantine. Rapid and accurate screening tests are urgently required to protect and prevent plant diseases spreading worldwide. A novel multiplex detection method was developed based on microsphere immunoassays to simultaneously detect four important plant pathogens: a fruit blotch bacterium Acidovorax avenae subsp. citrulli (Aac, chilli vein-banding mottle virus (CVbMV, potyvirus, watermelon silver mottle virus (WSMoV, tospovirus serogroup IV and melon yellow spot virus (MYSV, tospovirus. An antibody for each plant pathogen was linked on a fluorescence-coded magnetic microsphere set which was used to capture corresponding pathogen. The presence of pathogens was detected by R-phycoerythrin (RPE-labeled antibodies specific to the pathogens. The assay conditions were optimized by identifying appropriate antibody pairs, blocking buffer, concentration of RPE-labeled antibodies and assay time. Once conditions were optimized, the assay was able to detect all four plant pathogens precisely and accurately with substantially higher sensitivity than enzyme-linked immunosorbent assay (ELISA when spiked in buffer and in healthy watermelon leaf extract. The assay time of the microsphere immunoassay (1 hour was much shorter than that of ELISA (4 hours. This system was also shown to be capable of detecting the pathogens in naturally infected plant samples and is a major advancement in plant pathogen detection.

  11. Multiplex detection of plant pathogens using a microsphere immunoassay technology.

    Science.gov (United States)

    Charlermroj, Ratthaphol; Himananto, Orawan; Seepiban, Channarong; Kumpoosiri, Mallika; Warin, Nuchnard; Oplatowska, Michalina; Gajanandana, Oraprapai; Grant, Irene R; Karoonuthaisiri, Nitsara; Elliott, Christopher T

    2013-01-01

    Plant pathogens are a serious problem for seed export, plant disease control and plant quarantine. Rapid and accurate screening tests are urgently required to protect and prevent plant diseases spreading worldwide. A novel multiplex detection method was developed based on microsphere immunoassays to simultaneously detect four important plant pathogens: a fruit blotch bacterium Acidovorax avenae subsp. citrulli (Aac), chilli vein-banding mottle virus (CVbMV, potyvirus), watermelon silver mottle virus (WSMoV, tospovirus serogroup IV) and melon yellow spot virus (MYSV, tospovirus). An antibody for each plant pathogen was linked on a fluorescence-coded magnetic microsphere set which was used to capture corresponding pathogen. The presence of pathogens was detected by R-phycoerythrin (RPE)-labeled antibodies specific to the pathogens. The assay conditions were optimized by identifying appropriate antibody pairs, blocking buffer, concentration of RPE-labeled antibodies and assay time. Once conditions were optimized, the assay was able to detect all four plant pathogens precisely and accurately with substantially higher sensitivity than enzyme-linked immunosorbent assay (ELISA) when spiked in buffer and in healthy watermelon leaf extract. The assay time of the microsphere immunoassay (1 hour) was much shorter than that of ELISA (4 hours). This system was also shown to be capable of detecting the pathogens in naturally infected plant samples and is a major advancement in plant pathogen detection.

  12. Modified microspheres for cleaning liquid wastes from radioactive nuclides

    International Nuclear Information System (INIS)

    Danilin, Lev; Drozhzhin, Valery

    2007-01-01

    An effective solution of nuclear industry problems related to deactivation of technological and natural waters polluted with toxic and radioactive elements is the development of inorganic sorbents capable of not only withdrawing radioactive nuclides, but also of providing their subsequent conservation under conditions of long-term storage. A successful technical approach to creation of sorbents can be the use of hollow aluminosilicate microspheres. Such microspheres are formed from mineral additives during coal burning in furnaces of boiler units of electric power stations. Despite some reduction in exchange capacity per a mass unit of sorbents the latter have high kinetic characteristics that makes it possible to carry out the sorption process both in static and dynamic modes. Taking into account large industrial resources of microspheres as by-products of electric power stations, a comparative simplicity of the modification process, as well as good kinetic and capacitor characteristics, this class of sorbents can be considered promising enough for solving the problems of cleaning liquid radioactive wastes of various pollution levels. (authors)

  13. Quality Assurance Issues for Therapeutic Application of Radioactive Microspheres

    International Nuclear Information System (INIS)

    Dezarn, William A.

    2008-01-01

    The use of radioactive microspheres for the treatment of hepatic cancer is a procedure that raises unique quality assurance (QA) concerns. The greatest of these concerns is the coordination of the responsibilities among the medical team members from interventional radiology, radiation oncology, nuclear medicine, and medical physics. A single QA practice and procedure guidance document does not currently exist that addresses the range of issues of concern for radioactive microspheres. A small sampling of QA issues of concern include imaging QA, procedure-specific imaging protocols, detector calibration, activity measurement, radiation safety, patient dose calculations, and patient-specific QA. Some of the items listed have historically been the responsibility of a single team member, and other items have been concerns for all. A procedural overview of the therapeutic application of radioactive microspheres is presented to illustrate the broad, team-based QA approach necessary to safely and effectively deliver this type of treatment. From this overview, the reader will be able to customize the local QA protocol to meet the local division of responsibilities

  14. Recent progress on the fabrication of hollow microspheres

    International Nuclear Information System (INIS)

    Wang Aijuan; Lu Yupeng; Sun Ruixue

    2007-01-01

    Hollow microspheres represent a special class of materials, on which intense interest has been paid in the fields of material science, medicine, chemistry and chromatography. Several methods, including templating method, emulsion processing, high temperature smelting and layer-by-layer self-assembly technique, have been used to produce this kind of materials. However, most of the current needs for hollow microspheres are limited because of the disadvantages of these fabricating methods, such as time-consuming and relatively complex fabricating process. Spray drying method, as a simple and feasible technology, has also been used to fabricate this kind of materials. This method can improve the efficiency and save the time to some extent, and thus gains more and more interest recently. The factors of influencing the product morphology, including inlet air temperature, atomized pressure, feed rate, initial slurry concentration, primary powders size and additives, are reviewed in this paper. In addition, several kinds of typical hollow microspheres fabricated by this method are also listed particularly

  15. Magnetic microspheres as magical novel drug delivery system: A review

    Directory of Open Access Journals (Sweden)

    Satinder Kakar

    2013-01-01

    Full Text Available Magnetic microspheres hold great promise for reaching the goal of controlled and site specific drug delivery. Magnetic microspheres as an alternative to traditional radiation methods which uses highly penetrating radiations that is absorbed throughout the body. Its use is limited by toxicity and side effects. Now days, several targeted treatment systems including magnetic field, electric field, ultrasound, temperature, UV light and mechanical force are being used in many disease treatments (e.g. cancer, nerve damage, heart and artery, anti-diabetic, eye and other medical treatments. Among them, the magnetic targeted drug delivery system is one of the most attractive and promising strategy for delivering the drug to the specified site. Magnetically controlled drug targeting is one of the various possible ways of drug targeting. This technology is based on binding establish anticancer drug with ferrofluid that concentrate the drug in the area of interest (tumor site by means of magnetic fields. There has been keen interest in the development of a magnetically target drug delivery system. These drug delivery systems aim to deliver the drug at a rate directed by the needs of the body during the period of treatment, and target the activity entity to the site of action. Magnetic microspheres were developed to overcome two major problems encountered in drug targeting namely: RES clearance and target site specificity.

  16. Polymer-coated albumin microspheres as carriers for intravascular tumour targeting of cisplatin.

    Science.gov (United States)

    Verrijk, R; Smolders, I J; McVie, J G; Begg, A C

    1991-01-01

    We used a poly-lactide-co-glycolide polymer (PLAGA 50:50) to formulate cisplatin (cDDP) into microspheres designed for intravascular administration. Two systems were developed. PLAGA-coated albumin microspheres and microspheres consisting of PLAGA only. PLAGA-coated microspheres displayed a mean diameter of 31.8 +/- 0.9 microns and a payload of 7.5% cDDP (w/w). Solid PLAGA microspheres exhibited a mean diameter of 19.4 +/- 0.6 microns and a payload of 20% cDDP. Release characteristics and in vitro effects on L1210 leukemia and B16 melanoma cell lines were investigated. Both types of microsphere overcame the initial rapid release of cDDP (burst effect), and PLAGA-coated albumin microspheres also showed a lag phase of approximately 30 min before cDDP release began. PLAGA-coated albumin microspheres released most of their payload through diffusion, and the coating eventually cracked after 7 days' incubation in saline supplemented with 0.1% Tween at 37 degrees C, enabling the release of any cDDP remaining. Effects of platinum, pre-released from PLAGA-coated albumin microspheres on the in vitro growth of L1210 cells were comparable with those of standard formulations (dissolved) of cDDP. Material released from non-drug-loaded PLAGA microspheres had no effect on L1210 cell growth, suggesting the absence of cytotoxic compounds in the matrix. The colony-forming ability of B16 cells was also equally inhibited by standard cDDP and pre-released drug. These studies show that formulation of cDDP in PLAGA-based microspheres prevents the rapid burst effect of cDDP seen in previous preparations and offers an improved system of administration for hepatic artery infusion or adjuvant therapy, enabling better clinical handling and the promise of a higher ratio of tumour tissue to normal tissue.

  17. Preparation of magnetic polylactic acid microspheres and investigation of its releasing property for loading curcumin

    Energy Technology Data Exchange (ETDEWEB)

    Li Fengxia [Heilongjiang Key Laboratory of Molecular Design and Preparation of Flame Retarded Materials, College of Science, Northeast Forestry University, Harbin 150040 (China); Li Xiaoli, E-mail: lixiaoli0903@163.com [Heilongjiang Key Laboratory of Molecular Design and Preparation of Flame Retarded Materials, College of Science, Northeast Forestry University, Harbin 150040 (China); Li Bin, E-mail: libinzh62@163.com [Heilongjiang Key Laboratory of Molecular Design and Preparation of Flame Retarded Materials, College of Science, Northeast Forestry University, Harbin 150040 (China)

    2011-11-15

    In order to obtain a targeting drug carrier system, magnetic polylactic acid (PLA) microspheres loading curcumin were synthesized by the classical oil-in-water emulsion solvent-evaporation method. In the Fourier transform infrared spectra of microspheres, the present functional groups of PLA were all kept invariably. The morphology and size distribution of magnetic microspheres were observed with scanning electron microscopy and dynamic light scattering, respectively. The results showed that the microspheres were regularly spherical and the surface was smooth with a diameter of 0.55-0.75 {mu}m. Magnetic Fe{sub 3}O{sub 4} was loaded in PLA microspheres and the content of magnetic particles was 12 wt% through thermogravimetric analysis. The magnetic property of prepared microspheres was measured by vibrating sample magnetometer. The results showed that the magnetic microspheres exhibited typical superparamagnetic behavior and the saturated magnetization was 14.38 emu/g. Through analysis of differential scanning calorimetry, the curcumin was in an amorphous state in the magnetic microspheres. The drug loading, encapsulation efficiency and releasing properties of curcumin in vitro were also investigated by ultraviolet-visible spectrum analysis. The results showed that the drug loading and encapsulation efficiency were 8.0% and 24.2%, respectively. And curcumin was obviously slowly released because the cumulative release percentage of magnetic microspheres in the phosphate buffer (pH=7.4) solution was only 49.01% in 72 h, and the basic release of curcumin finished in 120 h. - Highlights: > We prepare magnetic polylactic acid microspheres loading curcumin. > The classical oil-in-water emulsion solvent-evaporation method is used. > The magnetic microspheres are regularly spherical with a diameter of 0.55-0.75 {mu}m. > They show a certain sustained release effect on in vitro drug releasing.

  18. Mobilization of microspheres from a fractured soil during intermittent infiltration events

    Science.gov (United States)

    Mohanty, Sanjay; Bulicek, Mark; Metge, David W.; Harvey, Ronald W.; Ryan, Joseph N.; Boehm, Alexandria B.

    2015-01-01

    Pathogens or biocolloids mobilized in the vadose zone may consequently contaminate groundwater. We found that microspheres were mobilized from a fractured soil during intermittent rainfall and the mobilization was greater when the microsphere size was larger and when the soil had greater water permeability.The vadose zone filters pathogenic microbes from infiltrating water and consequently protects the groundwater from possible contamination. In some cases, however, the deposited microbes may be mobilized during rainfall and migrate into the groundwater. We examined the mobilization of microspheres, surrogates for microbes, in an intact core of a fractured soil by intermittent simulated rainfall. Fluorescent polystyrene microspheres of two sizes (0.5 and 1.8 mm) and Br− were first applied to the core to deposit the microspheres, and then the core was subjected to three intermittent infiltration events to mobilize the deposited microspheres. Collecting effluent samples through a 19-port sampler at the base of the core, we found that water flowed through only five ports, and the flow rates varied among the ports by a factor of 12. These results suggest that flow paths leading to the ports had different permeabilities, partly due to macropores. Although 40 to 69% of injected microspheres were retained in the core during their application, 12 to 30% of the retained microspheres were mobilized during three intermittent infiltration events. The extent of microsphere mobilization was greater in flow paths with greater permeability, which indicates that macropores could enhance colloid mobilization during intermittent infiltration events. In all ports, the 1.8-mm microspheres were mobilized to a greater extent than the 0.5-mm microspheres, suggesting that larger colloids are more likely to mobilize. These results are useful in assessing the potential of pathogen mobilization and colloid-facilitated transport of contaminants in the subsurface under natural infiltration

  19. Preparation of magnetic polylactic acid microspheres and investigation of its releasing property for loading curcumin

    International Nuclear Information System (INIS)

    Li Fengxia; Li Xiaoli; Li Bin

    2011-01-01

    In order to obtain a targeting drug carrier system, magnetic polylactic acid (PLA) microspheres loading curcumin were synthesized by the classical oil-in-water emulsion solvent-evaporation method. In the Fourier transform infrared spectra of microspheres, the present functional groups of PLA were all kept invariably. The morphology and size distribution of magnetic microspheres were observed with scanning electron microscopy and dynamic light scattering, respectively. The results showed that the microspheres were regularly spherical and the surface was smooth with a diameter of 0.55-0.75 μm. Magnetic Fe 3 O 4 was loaded in PLA microspheres and the content of magnetic particles was 12 wt% through thermogravimetric analysis. The magnetic property of prepared microspheres was measured by vibrating sample magnetometer. The results showed that the magnetic microspheres exhibited typical superparamagnetic behavior and the saturated magnetization was 14.38 emu/g. Through analysis of differential scanning calorimetry, the curcumin was in an amorphous state in the magnetic microspheres. The drug loading, encapsulation efficiency and releasing properties of curcumin in vitro were also investigated by ultraviolet-visible spectrum analysis. The results showed that the drug loading and encapsulation efficiency were 8.0% and 24.2%, respectively. And curcumin was obviously slowly released because the cumulative release percentage of magnetic microspheres in the phosphate buffer (pH=7.4) solution was only 49.01% in 72 h, and the basic release of curcumin finished in 120 h. - Highlights: → We prepare magnetic polylactic acid microspheres loading curcumin. → The classical oil-in-water emulsion solvent-evaporation method is used. → The magnetic microspheres are regularly spherical with a diameter of 0.55-0.75 μm. → They show a certain sustained release effect on in vitro drug releasing.

  20. Preoperative Chemotherapy Versus Preoperative Chemoradiotherapy for Stage III (N2) Non-Small-Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Higgins, Kristin [Department of Radiation Oncology, Duke University of Medical Center, Durham, NC (United States); Chino, Junzo P [Department of Radiation Oncology, Duke University of Medical Center, Durham, NC (United States); Marks, Lawrence B [Department of Radiation Oncology, University of North Carolina, Chapel Hill, NC (United States); Ready, Neal [Department of Medicine, Division of Medical Oncology, Duke University of Medical Center, Durham, NC (United States); D' Amico, Thomas A [Department of Surgery, Division of Cardiovascular and Thoracic Surgery, Duke University of Medical Center, Durham, NC (United States); Clough, Robert W; Kelsey, Chris R [Department of Radiation Oncology, Duke University of Medical Center, Durham, NC (United States)

    2009-12-01

    Purpose: To compare preoperative chemotherapy (ChT) and preoperative chemoradiotherapy (ChT-RT) in operable Stage III non-small-cell lung cancer. Methods and Materials: This retrospective study analyzed all patients with pathologically confirmed Stage III (N2) non-small-cell lung cancer who initiated preoperative ChT or ChT-RT at Duke University between 1995 and 2006. Mediastinal pathologic complete response (pCR) rates were compared using a chi-square test. The actuarial overall survival, disease-free survival, and local control were estimated using the Kaplan-Meier method and compared using the log-rank test. Multivariate Cox regression analysis was also performed. Results: A total of 101 patients who initiated preoperative therapy with planned resection were identified. The median follow-up was 20 months for all patients and 38 months for survivors. The mediastinal lymph nodes were reassessed after preoperative therapy in 88 patients (87%). Within this group, a mediastinal pCR was achieved in 35% after preoperative ChT vs. 65% after preoperative ChT-RT (p = 0.01). Resection was performed in 69% after ChT and 84% after ChT-RT (p = 0.1). For all patients, the overall survival, disease-free survival, and local control rate at 3 years was 40%, 27%, and 66%, respectively. No statistically significant differences were found in the clinical endpoints between the ChT and ChT-RT subgroups. On multivariate analysis, a mediastinal pCR was associated with improved disease-free survival (p = 0.03) and local control (p = 0.03), but not overall survival (p = 0.86). Conclusion: Preoperative ChT-RT was associated with higher mediastinal pCR rates but not improved survival.

  1. Preoperative Chemotherapy Versus Preoperative Chemoradiotherapy for Stage III (N2) Non-Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Higgins, Kristin; Chino, Junzo P.; Marks, Lawrence B.; Ready, Neal; D'Amico, Thomas A.; Clough, Robert W.; Kelsey, Chris R.

    2009-01-01

    Purpose: To compare preoperative chemotherapy (ChT) and preoperative chemoradiotherapy (ChT-RT) in operable Stage III non-small-cell lung cancer. Methods and Materials: This retrospective study analyzed all patients with pathologically confirmed Stage III (N2) non-small-cell lung cancer who initiated preoperative ChT or ChT-RT at Duke University between 1995 and 2006. Mediastinal pathologic complete response (pCR) rates were compared using a chi-square test. The actuarial overall survival, disease-free survival, and local control were estimated using the Kaplan-Meier method and compared using the log-rank test. Multivariate Cox regression analysis was also performed. Results: A total of 101 patients who initiated preoperative therapy with planned resection were identified. The median follow-up was 20 months for all patients and 38 months for survivors. The mediastinal lymph nodes were reassessed after preoperative therapy in 88 patients (87%). Within this group, a mediastinal pCR was achieved in 35% after preoperative ChT vs. 65% after preoperative ChT-RT (p = 0.01). Resection was performed in 69% after ChT and 84% after ChT-RT (p = 0.1). For all patients, the overall survival, disease-free survival, and local control rate at 3 years was 40%, 27%, and 66%, respectively. No statistically significant differences were found in the clinical endpoints between the ChT and ChT-RT subgroups. On multivariate analysis, a mediastinal pCR was associated with improved disease-free survival (p = 0.03) and local control (p = 0.03), but not overall survival (p = 0.86). Conclusion: Preoperative ChT-RT was associated with higher mediastinal pCR rates but not improved survival.

  2. Synthesis of plastic scintillation microspheres: Evaluation of scintillators

    International Nuclear Information System (INIS)

    Santiago, L.M.; Bagán, H.; Tarancón, A.; Garcia, J.F.

    2013-01-01

    The use of plastic scintillation microspheres (PSm) appear to be an alternative to liquid scintillation for the quantification of alpha and beta emitters because it does not generate mixed wastes after the measurement (organic and radioactive). In addition to routine radionuclide determinations, PSm can be used for further applications, e.g. for usage in a continuous monitoring equipment, for measurements of samples with a high salt concentration and for an extractive scintillation support which permits the separation, pre-concentration and measurement of the radionuclides without additional steps of elution and sample preparation. However, only a few manufacturers provide PSm, and the low number of regular suppliers reduces its availability and restricts the compositions and sizes available. In this article, a synthesis method based on the extraction/evaporation methodology has been developed and successfully used for the synthesis of plastic scintillation microspheres. Seven different compositions of plastic scintillation microspheres have been synthesised; PSm1 with polystyrene, PSm2 with 2,5-Diphenyloxazol(PPO), PSm3 with p-terphenyl (pT), PSm4 with PPO and 1,4-bis(5-phenyloxazol-2-yl) (POPOP), PSm5 pT and (1,4-bis [2-methylstyryl] benzene) (Bis-MSB), PSm6 with PPO, POPOP and naphthalene and PSm7 with pT, Bis-MSB and naphthalene. The synthesised plastic scintillation microspheres have been characterised in terms of their morphology, detection capabilities and alpha/beta separation capacity. The microspheres had a median diameter of approximately 130 μm. Maximum detection efficiency values were obtained for the PSm4 composition as follows 1.18% for 3 H, 51.2% for 14 C, 180.6% for 90 Sr/ 90 Y and 76.7% for 241 Am. Values of the SQP(E) parameter were approximately 790 for PSm4 and PSm5. These values show that the synthesised PSm exhibit good scintillation properties and that the spectra are at channel numbers higher than in commercial PSm. Finally, the addition

  3. The influence of increased cross-linker chain length in thermosensitive microspheres on potential sun-protection activity

    OpenAIRE

    Musiał, Witold; Kokol, Vanja; Vončina, Bojana

    2012-01-01

    The sun protection should involve substances with protecting activity against both UVB and UVA radiation. In this research the evaluation of thermosensitive microspheres as potential molecules for sunscreen formulations was approached, using modified Boots star rating system. The microspheres, thermosensitive N-isopropylacrylamide derivatives, have potential protecting activity against UV radiation. The MX and DX microspheres, with ethylene glycol dimethacrylate and diethylene glycol dimethac...

  4. Preoperative blood transfusions for sickle cell disease

    Science.gov (United States)

    Estcourt, Lise J; Fortin, Patricia M; Trivella, Marialena; Hopewell, Sally

    2016-01-01

    Background Sickle cell disease is one of the commonest severe monogenic disorders in the world, due to the inheritance of two abnormal haemoglobin (beta globin) genes. Sickle cell disease can cause severe pain, significant end-organ damage, pulmonary complications, and premature death. Surgical interventions are more common in people with sickle cell disease, and occur at much younger ages than in the general population. Blood transfusions are frequently used prior to surgery and several regimens are used but there is no consensus over the best method or the necessity of transfusion in specific surgical cases. This is an update of a Cochrane review first published in 2001. Objectives To determine whether there is evidence that preoperative blood transfusion in people with sickle cell disease undergoing elective or emergency surgery reduces mortality and perioperative or sickle cell-related serious adverse events. To compare the effectiveness of different transfusion regimens (aggressive or conservative) if preoperative transfusions are indicated in people with sickle cell disease. Search methods We searched for relevant trials in The Cochrane Library, MEDLINE (from 1946), Embase (from 1974), the Transfusion Evidence Library (from 1980), and ongoing trial databases; all searches current to 23 March 2016. We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group Trials Register: 18 January 2016. Selection criteria All randomised controlled trials and quasi-randomised controlled trials comparing preoperative blood transfusion regimens to different regimens or no transfusion in people with sickle cell disease undergoing elective or emergency surgery. There was no restriction by outcomes examined, language or publication status. Data collection and analysis Two authors independently assessed trial eligibility and the risk of bias and extracted data. Main results Three trials with 990 participants were eligible for inclusion in the review. There were no

  5. Photocatalytic activities of heterostructured TiO2-graphene porous microspheres prepared by ultrasonic spray pyrolysis

    International Nuclear Information System (INIS)

    Yang, Jikai; Zhang, Xintong; Li, Bing; Liu, Hong; Sun, Panpan; Wang, Changhua; Wang, Lingling; Liu, Yichun

    2014-01-01

    Highlights: • USP method is used to prepare TiO 2 -graphene porous microspheres. • XPS shows GO sheets in the composites has been reduced to graphene. • TiO 2 -graphene microspheres display a red-shifted absorption edge. • PL spectra indicate graphene can accept the photoexcited electrons from TiO 2 . • TiO 2 -graphene shows higher photocatalytic activity than TiO 2 under solar light. -- Abstract: TiO 2 -graphene porous microspheres were prepared by ultrasonic spray pyrolysis (USP) of aqueous suspension of graphene oxide containing TiO 2 nanoparticles (Degussa P25). The composite microspheres were characterized with SEM, XPS, photoluminescence, Raman and UV–Vis absorption spectra. TiO 2 -graphene porous microspheres displayed higher photocatalytic activity for the degradation of methylene blue solution than pristine TiO 2 microspheres under the irradiation of Xe lamp, and the highest activity was obtained at a weight percentage of graphene around 1%. The effect of graphene on photocatalytic activity of porous microsphere was discussed in terms of the enhanced charge separation by TiO 2 -graphene heterojunction, increased absorption of the visible light, as well as the possible hindrance of mass transportation in microspheres

  6. Dual Drug Loaded Biodegradable Nanofibrous Microsphere for Improving Anti-Colon Cancer Activity

    Science.gov (United States)

    Fan, Rangrang; Li, Xiaoling; Deng, Jiaojiao; Gao, Xiang; Zhou, Liangxue; Zheng, Yu; Tong, Aiping; Zhang, Xiaoning; You, Chao; Guo, Gang

    2016-06-01

    One of the approaches being explored to increase antitumor activity of chemotherapeutics is to inject drug-loaded microspheres locally to specific anatomic sites, providing for a slow, long term release of a chemotherapeutic while minimizing systemic exposure. However, the used clinically drug carriers available at present have limitations, such as their low stability, renal clearance and residual surfactant. Here, we report docetaxel (DOC) and curcumin (CUR) loaded nanofibrous microspheres (DOC + CUR/nanofibrous microspheres), self-assembled from biodegradable PLA-PEO-PPO-PEO-PLA polymers as an injectable drug carrier without adding surfactant during the emulsification process. The obtained nanofibrous microspheres are composed entirely of nanofibers and have an open hole on the shell without the assistance of a template. It was shown that these DOC + CUR/nanofibrous microspheres could release curcumin and docetaxel slowly in vitro. The slow, sustained release of curcumin and docetaxel in vivo may help maintain local concentrations of active drug. The mechanism by which DOC + CUR/nanofibrous microspheres inhibit colorectal peritoneal carcinomatosis might involve increased induction of apoptosis in tumor cells and inhibition of tumor angiogenesis. In vitro and in vivo evaluations demonstrated efficacious synergistic antitumor effects against CT26 of curcumin and docetaxel combined nanofibrous microspheres. In conclusion, the dual drug loaded nanofibrous microspheres were considered potentially useful for treating abdominal metastases of colorectal cancer.

  7. Carbidopa/levodopa-loaded biodegradable microspheres: in vivo evaluation on experimental Parkinsonism in rats.

    Science.gov (United States)

    Arica, Betül; Kaş, H Süheyla; Moghdam, Amir; Akalan, Nejat; Hincal, A Atilla

    2005-02-16

    The purpose of this study was to prepare and characterize injectable carbidopa (CD)/levodopa (LD)-loaded Poly(L-lactides) (L-PLA), Poly(D,L-lactides) (D,L-PLA) and Poly(D,L-lactide-co-glycolide) (PLAGA) microspheres for the intracerebral treatment of Parkinson's disease. The microspheres were prepared by solvent evaporation method. The polymers' (L-PLA, D,L-PLA and PLAGA) concentrations were 10% (w/w) in the organic phase; the emulsifiers [sodium carboxymethylcellulose (NaCMC):sodium oleate (SO) and Polyvinyl alcohol (PVA):SO mixture (4:1 w/v)] concentrations were 0.75% in the aqueous phase. Microspheres were analyzed for morphological characteristics, size distribution, drug loading and in vitro release. The release profile of CD/LD from microspheres was characterized in the range of 12-35% within the first hour of the in vitro release experiment. The efficiency of CD- and LD-encapsulated microspheres to striatal transplantation and the altering of apomorphine-induced rotational behavior in the 6-hydroxydopamine (6-OHDA) unilaterally lesioned rat model were also tested. 6-OHDA/CD-LD-loaded microsphere groups exhibited lower rotation scores than 6-OHDA/Blank microsphere groups as early as 1 week postlesion. These benefits continued throughout the entire experimental period and they were statistically significant during the 1, 2 and 8 weeks (p<0.05). CD/LD-loaded microspheres were specifically prepared to apply as an injectable dosage forms for brain implantation.

  8. Influence of polymeric microspheres on the myocardial oxygen partial pressure in the beating heart of pigs.

    Science.gov (United States)

    Hiebl, B; Mrowietz, C; Lee, S; Braune, S; Knaut, M; Lendlein, A; Franke, R P; Jung, F

    2011-07-01

    Injection of labeled microspheres is an established method in animal models to analyze the capillary organ blood flow at different time points. However, the microspheres can lead to stenoses of the capillary lumen, which might affect tissue oxygen supply. Our study aimed to investigate the influence of repeated injections of microspheres into the left coronary artery on the tissue oxygen partial pressure (pO(2)) in the downstream supplied myocardium of Göttingen minipigs. Tests (n=6 pigs each) were performed with two differently sized microspheres (ø=10 ± 0.1 μm (M10) or ø=15 ± 0.15 μm (M15)) from polystyrene. The pO(2) was measured in the midmyocardium of the left and right ventricle for 6 min continuously after each of five injections (1 × 10(6) microspheres each). There was a time laps of 12 min between each injection. In addition, the influence of the carrier solution was analyzed solely in the identical time frame. pO(2) decreased significantly in the myocardial area supplied by the ramus interventricularis paraconalis after injection of M15 microspheres. In contrast, the application of the M10 microspheres did not change the myocardial pO(2). This finding suggests to use microspheres with diameters not exceeding 10 μm for the coronary blood flow assessment. Copyright © 2011 Elsevier Inc. All rights reserved.

  9. 5-Fluorouracil:carnauba wax microspheres for chemoembolization: an in vitro evaluation.

    Science.gov (United States)

    Benita, S; Zouai, O; Benoit, J P

    1986-09-01

    5-Fluorouracil:carnauba wax microspheres were prepared using a meltable dispersion process with the aid of a surfactant as a wetting agent. It was noted that only hydrophilic surfactants were able to wet the 5-fluorouracil and substantially increased its content in the microspheres. No marked effect was observed in the particle size distribution of the solid microspheres as a function of the nature of the surfactant. Increasing the stirring rate in the preparation process decreased, first, the mean droplet size of the emulsified melted dispersion in the vehicle during the heating process, and, consequently, the mean particle size of the solidified microspheres during the cooling process. 5-Fluorouracil cumulative release from the microspheres followed first-order kinetics, as shown by nonlinear regression analysis. Although the kinetic results were not indicative of the true release mechanism from a single microsphere, it was believed that 5-fluorouracil release from the microspheres was probably governed by a dissolution process, rather than by a leaching process through the carnauba wax microspheres.

  10. Effect of Fabrication Process Parameters on the Size of Gelatin/Nanohydroxyapatite Microspheres

    Directory of Open Access Journals (Sweden)

    S. Bagheri-Khoulenjani

    2009-12-01

    Full Text Available Nano-hydroxyapatite/gelatin (nHA/Ge microspheres are currently used in bone tissue engineering as bone filler. In this  study, the effect of fabrication process parameters on the particle size of nano-hydroxyapatite/gelatinmicrospheres was investigated. The nHA/Ge microspheres were fabricated using water in oil emulsion. In order to design an experimental design, a surface response model with 2 factors including the rate of shaking and water to oil volume ratio in 3 levels was applied. Particle size was evaluated by using an optical microscope. The morphology of microspheres and distribution of nano-particles within the microspheres were studied by using scanning electron microscope and Ca elemental map obtained from energy dispersive X-ray analysis (EDX, respectively. Statistical analysis of the results obtained from particle size measurements revealed that the rate of shaking has stronger influence on the particle size of microspheres. Morphological studies showed that the fabricated microspheres were spherical with smooth surface. Ca elemental map of the microspheres showed that nano-hydroxyapatite particles distributed uniformly within the microspheres.

  11. Chitosan and Nanohydroxyapatite Roles in Physical and Chemical Characteristics of Gelatin/Chitosan/Nanohydroxyapatite Microspheres

    Directory of Open Access Journals (Sweden)

    S. Bagheri-Khoulenjani

    2010-12-01

    Full Text Available The effects of chitosan/biopolymer (C/P and nanohydroxyapatite/ biopolymer (nHA/P weight ratios on particle size and its uniformity, cross-linking density and NH2 content of nano-hydroxyapatite/chitosan/gelatin (nHA/C/G microspheres were investigated. Microspheres were fabricated using water-in-oil emulsion. Cross-linking of microspheres was performed using water soluble carbodiimide. Particle size and its uniformity were evaluated using an optical microscope. The morphology of microspheres was studied by scanning electron microscopy. The obtained data from particle size measurements revealed that increments in C/P ratio increased the particle size while reducing its uniformity, and increased the NH2 content and cross linking density of the microspheres. It was shown that incremental increase in nHA/P ratio increased the particle size and its uniformity and reduced the NH2 content and cross-linking density of the microspheres.Morphological studies showed that the fabricated microspheres had spherical shape in medium level of C/P ratio and nHA/P ratio. However, increasing in chitosan/biopolymer ratio induced some micro-cracks into the structure of microspheres.

  12. Kinetics of piroxicam release from low-methylated pectin/zein hydrogel microspheres

    Science.gov (United States)

    The kinetics of a model drug (piroxicam) release from pectin/zein hydrogel microspheres was studied under conditions simulating the gastrointestinal tract. It is established that the rate-limiting step in the release mechanism is drug diffusion out of the microspheres rather than its dissolution. ...

  13. Eudragit-coated dextran microspheres of 5-fluorouracil for site-specific delivery to colon.

    Science.gov (United States)

    Rai, Gopal; Yadav, Awesh K; Jain, Narendra K; Agrawal, Govind P

    2016-01-01

    Objective of the present investigation was to prepare and evaluate the potential of enteric coated dextran microspheres for colon targeting of 5-fluorouracil (5-FU). Dextran microspheres were prepared by emulsification-crosslinking method and the formulation variables studied included different molecular weights of dextran, drug:polymer ratio, volume of crosslinking agent, stirring speed and time. Enteric coating (Eudragit S-100) of dextran microspheres was performed by oil-in-oil solvent evaporation method using different coat:core ratios (4:1 or 8:1). Uncoated and coated dextran microspheres were characterized by particle size, surface morphology, entrapment efficiency, DSC, in vitro drug release in the presence of dextranase and 2% rat cecal contents. The release study of 5-FU from coated dextran microspheres was pH dependent. No release was observed at acidic pH; however, the drug was released quickly where Eudragit starts solublizing there was continuous release of drug from the microspheres. Organ distribution study was suggested that coated dextran microspheres retard the release of drug in gastric and intestinal pH environment and released of drug from microspheres in colon due to the degradation of dextran by colonic enzymes.

  14. Enteric-coated epichlorohydrin crosslinked dextran microspheres for site-specific delivery to colon.

    Science.gov (United States)

    Rai, Gopal; Yadav, Awesh K; Jain, Narendra K; Agrawal, Govind P

    2015-01-01

    Enteric-coated epichlorohydrin crosslinked dextran microspheres containing 5-Fluorouracil (5-FU) for colon drug delivery was prepared by emulsification-crosslinking method. The formulation variables studied includes different molecular weights of dextran, volume of crosslinking agent, stirring speed, time and temperature. Dextran microspheres showed mean entrapment efficiencies ranging between 77 and 87% and mean particle size ranging between 10 and 25 µm. About 90% of drug was released from uncoated dextran microspheres within 8 h, suggesting the fast release and indicated the drug loaded in uncoated microspheres, released before they reached colon. Enteric coating (Eudragit-S-100 and Eudragit-L-100) of dextran microspheres was performed by oil-in-oil solvent evaporation method. The release study of 5-FU from coated dextran microspheres was complete retardation in simulated gastric fluid (pH 1.2) and once the coating layer of enteric polymer was dissolved at higher pH (7.4 and 6.8), a controlled release of the drug from the microspheres was observed. Further, the release of drug was found to be higher in the presence of dextranase and rat caecal contents, indicating the susceptibility of dextran microspheres to colonic enzymes. Organ distribution and pharmacokinetic study in albino rats was performed to establish the targeting potential of optimized formulation in the colon.

  15. Multiplexed fluorescent microarray for human salivary protein analysis using polymer microspheres and fiber-optic bundles.

    Science.gov (United States)

    Nie, Shuai; Benito-Peña, Elena; Zhang, Huaibin; Wu, Yue; Walt, David R

    2013-10-10

    Herein, we describe a protocol for simultaneously measuring six proteins in saliva using a fiber-optic microsphere-based antibody array. The immuno-array technology employed combines the advantages of microsphere-based suspension array fabrication with the use of fluorescence microscopy. As described in the video protocol, commercially available 4.5 μm polymer microspheres were encoded into seven different types, differentiated by the concentration of two fluorescent dyes physically trapped inside the microspheres. The encoded microspheres containing surface carboxyl groups were modified with monoclonal capture antibodies through EDC/NHS coupling chemistry. To assemble the protein microarray, the different types of encoded and functionalized microspheres were mixed and randomly deposited in 4.5 μm microwells, which were chemically etched at the proximal end of a fiber-optic bundle. The fiber-optic bundle was used as both a carrier and for imaging the microspheres. Once assembled, the microarray was used to capture proteins in the saliva supernatant collected from the clinic. The detection was based on a sandwich immunoassay using a mixture of biotinylated detection antibodies for different analytes with a streptavidin-conjugated fluorescent probe, R-phycoerythrin. The microarray was imaged by fluorescence microscopy in three different channels, two for microsphere registration and one for the assay signal. The fluorescence micrographs were then decoded and analyzed using a homemade algorithm in MATLAB.

  16. Preparation and Comparative Bioavailability Studies of Indomethacin-Loaded Cetyl Alcohol Microspheres

    Directory of Open Access Journals (Sweden)

    N. Vishal Gupta

    2013-01-01

    Full Text Available The purpose of the present study was to compare the in vitro release and to find out whether the bioavailability of a 75 mg indomethacin capsule (Microcid SR was equivalent to optimized formulation (indomethacin-loaded cetyl alcohol microspheres. Indomethacin-loaded cetyl alcohol microspheres were prepared by meltable emulsified cooling-induced technique. Surface morphology of microspheres has been evaluated using scanning electron microscopy. A single dose, randomized, complete cross over study of IM microspheres was carried out on 10 healthy male and female Albino sheep’s under fasting conditions. The plasma was separated and the concentrations of the drug were determined by HPLC-UV method. Plasma indomethacin concentrations and other pharmacokinetic parameters obtained were statistically analyzed. The SEM images revealed the spherical shape of fat microspheres, and more than 98.0% of the isolated microspheres were in the size range 12–32 μm. DSC, FTIR spectroscopy and stability studies indicated that the drug after encapsulation with fat microspheres was stable and compatible. Both formulations were found to be bioequivalent as evidenced by in vivo studies. Based on this study, it can be concluded that cetyl alcohol microspheres and Microcid SR capsule are bioequivalent in terms of the rate and extent of absorption.

  17. ADRIAMYCIN-LOADED ALBUMIN-HEPARIN CONJUGATE MICROSPHERES FOR INTRAPERITONEAL CHEMOTHERAPY

    NARCIS (Netherlands)

    CREMERS, HFM; SEYMOUR, LW; LAM, K; LOS, G; KWON, G; BAE, YH; KIM, SW; FEIJEN, J

    1994-01-01

    Adriamycin-loaded albumin-heparin conjugate microspheres (ADR-AHCMS) were evaluated as possible intraperitoneal (i.p.) delivery systems for site-specific cytotoxic action. The biocompatibility of the microspheres after intraperitoneal injection was tested first. 1 day after i.p. administration of

  18. 188Re-microspheres of albumin - the potential preparation for radiotherapy

    International Nuclear Information System (INIS)

    Dyomin, D.N.; Petriev, V.M.

    2000-01-01

    In this paper author describe preparation the albumin microspheres labelled with rhenium-188. We undertake an attempt to develop kits to the generator of rhenium-188 on the basis of albumin microspheres for radiotherapy of both oncological and non-oncological diseases. Microspheres, rhenium-188 with sizes 1 0-20 micron for treatment of rheumatoid arthritis (damage of large and intermediate joints), intraperitoneal administration and intrapleural administration at metastases covering a cavity. Microspheres, Re-188 with sizes 40-60 micron for treatment of disseminated kidney cancer (intraarterial, selectively), intratumoral administration to damaged nodules less than 2-3 cm. Microspheres, Re-188 with sizes 80-100 micron for large neoplasms and metastases of liver (intraarterial, selectively), intratumoral administration to damaged nodules with sizes over 3 cm. Preparation of albumin microspheres is carried out by thermal denaturation of protein in vegetable oil. Microspheres are obtained with the necessary range of sizes by ultrasonic fractionation. At our laboratory the method of preparation of albumin microspheres with any sizes of particles (from 5 -10 up to 800 -1000 microns) has been developed. (authors)

  19. A Comparative Study of Production of Glass Microspheres by using Thermal Process

    Science.gov (United States)

    Lee, May Yan; Tan, Jully; Heng, Jerry YY; Cheeseman, Christopher

    2017-06-01

    Microspheres are spherical particles that can be distinguished into two categories; solid or hollow. Microspheres typical ranges from 1 to 200 μm in diameter. Microsphere are made from glass, ceramic, carbon or plastic depending on applications. Solid glass microsphere is manufactured by direct burning of glass powders while hollow glass microspheres is produced by adding blowing agent to glass powder. This paper presented the production of glass microspheres by using the vertical thermal flame (VTF) process. Pre-treated soda lime glass powder with particle sized range from 90 to 125μm was used in this work. The results showed that glass microspheres produced by two passes through the flame have a more spherical shape as compared with the single pass. Under the Scanning Electron Microscope (SEM), it is observed that there is a morphology changed from uneven surface of glass powders to smooth spherical surface particles. Qualitative analysis for density of the pre-burned and burned particles was performed. Burned particles floats in water while pre-burned particles sank indicated the change of density of the particles. Further improvements of the VTF process in terms of the VTF set-up are required to increase the transformation of glass powders to glass microspheres.

  20. Release of proteins via ion exchange from albumin-heparin microspheres

    NARCIS (Netherlands)

    Kwon, Glen S.; Bae, You Han; Cremers, H.F.M.; Cremers, Harry; Feijen, Jan; Kim, Sung Wan

    1992-01-01

    Albumin-heparin and albumin microspheres were prepared as ion exchange gels for the controlled release of positively charged polypeptides and proteins. The adsorption isotherms of chicken egg and human lysozyme, as model proteins, on microspheres were obtained. An adsorption isotherm of chicken egg

  1. Supercritical fluid extraction of silicone oil from uranate microspheres prepared by sol-gel process

    International Nuclear Information System (INIS)

    Kumar, R.; Venkatakrishnan, R.; Sivaraman, N.; Srinivasan, T.G.; Vasudeva Rao, P.R.

    2005-01-01

    Supercritical fluid extraction of silicone oil from urania microspheres prepared through sol-gel route was investigated. The influence of pressure, temperature, and flow rate on the extraction efficiency was studied. Experimental conditions were optimised for the complete removal of silicone oil from urania microspheres. (author)

  2. Pre-operative haematological investigations in paediatric orofacial ...

    African Journals Online (AJOL)

    Pre-operative haematological investigations in paediatric orofacial cleft repair: Any relevance to management outcome? ... Aim and Objectives: To determine the value of routine pre-operative haematologic investigations in children undergoing orofacial cleft repair. Background: Although routine pre-operative laboratory ...

  3. Preoperative modifiable risk factors in colorectal surgery

    DEFF Research Database (Denmark)

    van Rooijen, Stefanus; Carli, Francesco; Dalton, Susanne O

    2017-01-01

    in higher mortality rates and greater hospital costs. The number and severity of complications is closely related to patients' preoperative performance status. The aim of this study was to identify the most important preoperative modifiable risk factors that could be part of a multimodal prehabilitation...... program. METHODS: Prospectively collected data of a consecutive series of Dutch CRC patients undergoing colorectal surgery were analyzed. Modifiable risk factors were correlated to the Comprehensive Complication Index (CCI) and compared within two groups: none or mild complications (CCI ... complications (CCI ≥20). Multivariate logistic regression analysis was done to explore the combined effect of individual risk factors. RESULTS: In this 139 patient cohort, smoking, malnutrition, alcohol consumption, neoadjuvant therapy, higher age, and male sex, were seen more frequently in the severe...

  4. Evaluation of preoperative embolization of meningioma

    International Nuclear Information System (INIS)

    Park, Sung Tae; Suh, Dae Chul; Lee, Ho Kyu; Choi, Choong Gon; Lee, Myung Jun; Ji, Eun Kyung; Shin, Byung Suck; Kim, Chang Jin; Kim, Jong Uk; Whang, C. Jin

    1998-01-01

    To evaluate the efficacy and safety of preoperative embolization of intrancranial meningioma.Materials and Methods : We retrospectively reviewed intrancranial meningioma patients (n=37) who underwent preoperative embolization. They were categorized into two groups, skull base lesions (n=22) and non-skull base lesions (n=15), according to tumor location. In addition, embolization results were classified by comparison between pre- and post-embolization angiography as complete (residual tumor staining 10 or 30%). In each group, estimated blood loss (EBL) was estimated by amount of intraoperative transfusion with pre- and post-operative hemoglobin level. Tumor resectability was evaluated by follow-up computed tomography. New symptoms occurring within 24 hours of embolization were considered to be those associated with embolization ; symptoms improved by conservative treatment were regarded as mild, while those resulting in new deficits were considered severe. Results : In the group with skull base lesions (n=22), complete embolization with the criteria of residual tumor staining of less than 30% was performed in 14 patients(EBL=1770ml;complete surgical removal in nine patients and incomplete removal four). Incomplete embolization was performed in eight patients (EBL=3210ml; complete and incomplete removal each in four patients). In the group with non-skull base lesions, complete embolization with the criteria of residual tumor staining of less than 10% was performed in five patients (EBL=970ml) and incomplete embolization in ten (EBL=2260ml). Complete tumor removal was possible in this group regardless of the completeness of preoperative tumor embolization. In a case of intraventricular meningioma (3%), intratumoral hemorrhage occurred on the day following embolization. Other mild post-embolization complications occurred in three cases (8%). Conclusion : Preoperative embolization can be an effective and safe procedure for meningioma and may reduce intraoperative blood

  5. Religiousness and preoperative anxiety: a correlational study

    OpenAIRE

    Aghamohammadi Kalkhoran, Masoomeh; Karimollahi, Mansoureh

    2007-01-01

    Abstract Background Major life changes are among factors that cause anxiety, and one of these changes is surgery. Emotional reactions to surgery have specific effects on the intensity and velocity as well as the process of physical disease. In addition, they can cause delay in patients recovery. This study is aimed at determining the relationship between religious beliefs and preoperative anxiety. Methods This survey is a correlational study to assess the relationship between religious belief...

  6. Implications of preoperative hypoalbuminemia in colorectal surgery.

    OpenAIRE

    Truong, A; Hanna, MH; Moghadamyeghaneh, Z; Stamos, MJ

    2016-01-01

    Serum albumin has traditionally been used as a quantitative measure of a patient’s nutritional status because of its availability and low cost. While malnutrition has a clear definition within both the American and European Societies for Parenteral and Enteral Nutrition clinical guidelines, individual surgeons often determine nutritional status anecdotally. Preoperative albumin level has been shown to be the best predictor of mortality after colorectal cancer surgery. Specifically in colorect...

  7. Carboxyl-Functionalized Polymeric Microspheres Prepared by One-Stage Photoinitiated RAFT Dispersion Polymerization

    Directory of Open Access Journals (Sweden)

    Jianbo Tan

    2017-12-01

    Full Text Available Herein, we report a photoinitiated reversible addition-fragmentation chain transfer (RAFT dispersion copolymerization of methyl methacrylate (MMA and methyl methacrylic (MAA for the preparation of highly monodisperse carboxyl-functionalized polymeric microspheres. High rates of polymerization were observed, with more than 90% particle yields being achieved within 3 h of UV irradiation. Effects of reaction parameters (e.g., MAA concentration, RAFT agent concentration, photoinitiator concentration, and solvent composition were studied in detail, and highly monodisperse polymeric microspheres were obtained in most cases. Finally, silver (Ag composite microspheres were prepared by in situ reduction of AgNO3 using the carboxyl-functionalized polymeric microspheres as the template. The obtained Ag composite microspheres were able to catalyze the reduction of methylene blue (MB with NaBH4 as a reductant.

  8. Behaviour of (Th, U)O2 microspheres under compression tests and pelletization

    International Nuclear Information System (INIS)

    Ferreira, R.A.N.

    1982-12-01

    The interrelation between the behaviour of isolated microspheres in compression tests and the microstructure of sintered pellets obtained with these microspheres, was investigated. Various batches of (Th, 5 w/o U)O 2 microspheres were produced applying the so-called gel process. The production parameters were diversified both as to the composition and to the heat treatments. The resulting products underwent compression tests in an universal tension and compression machine as single microspheres and, as bulk material, were compacted and sintered. The results of the compression tests revealed the existence of two distinct classes of fragmentation behaviour. Each of these classes causes a distinct behaviour during the pelletization, too, resulting in fuel pellets with quite different microstructures. It was evidenced that there is a relationship between these differences in the microstructure and the behaviour of the single microspheres in the compression test. (Author) [pt

  9. [Optimization of calcium alginate floating microspheres loading aspirin by artificial neural networks and response surface methodology].

    Science.gov (United States)

    Zhang, An-yang; Fan, Tian-yuan

    2010-04-18

    To investigate the preparation and optimization of calcium alginate floating microspheres loading aspirin. A model was used to predict the in vitro release of aspirin and optimize the formulation by artificial neural networks (ANNs) and response surface methodology (RSM). The amounts of the material in the formulation were used as inputs, while the release and floating rate of the microspheres were used as outputs. The performances of ANNs and RSM were compared. ANNs were more accurate in prediction. There was no significant difference between ANNs and RSM in optimization. Approximately 90% of the optimized microspheres could float on the artificial gastric juice over 4 hours. 42.12% of aspirin was released in 60 min, 60.97% in 120 min and 78.56% in 240 min. The release of the drug from the microspheres complied with Higuchi equation. The aspirin floating microspheres with satisfying in vitro release were prepared successfully by the methods of ANNs and RSM.

  10. Synthesis of V2O5 microspheres by spray pyrolysis as cathode material for supercapacitors

    Science.gov (United States)

    Yin, Zhendong; Xu, Jie; Ge, Yali; Jiang, Qiaoya; Zhang, Yaling; Yang, Yawei; Sun, Yuping; Hou, Siyu; Shang, Yuanyuan; Zhang, Yingjiu

    2018-03-01

    Vanadium oxide (V2O5) microspheres have attracted considerable attention in the energy field due to their unique properties such as high stability and electrochemical activity. Here, massive V2O5 microspheres with smooth surface, hollow cavity and uniform particle sizes (0.4–1.5 μm), were synthesized by a facile spray pyrolysis process. Post-treatment at predefined temperatures effectively turned the microsphere shell into stacked nanorods with widths of 100 nm and lengths of 500 nm when processed at 500 °C for 3 h under nitrogen atmosphere, with enhanced crystallinity. When applied as cathode materials for supercapacitors, the post-treated V2O5 microspheres at 500 °C exhibited improved specific capacitance and longer discharge time. This is an effective method to manufacture massive V2O5 microspheres with tailored structure and potential applications in high-performance energy storage materials.

  11. Preparation of berbamine loaded chitosan-agarose microspheres and in vitro release study

    Directory of Open Access Journals (Sweden)

    Zhang Hu

    2012-01-01

    Full Text Available Berbamine loaded chitosan-agarose microspheres were prepared using a water-in-oil emulsion technique. Optimum preparing parameters were determined by orthogonal experiments as follows: ratio of berbamine to chitosan (w/w is 1:10; percentage of emulsifier (span 80, v/v is 6%; volume of glutaraldehyde is 2 mL; and reaction temperature is 70 ºC. Under these optimal conditions, the encapsulation efficiency and loading capacity of microspheres are 84.57% and 8.44%, respectively. The swelling tests showed that the microspheres possessed higher swelling ratio at pH 7.4 than at pH 1.2. FTIR indicated that berbamine had been successfully loaded in the chitosan-agarose microspheres by physical entrapment. In vitro release studies showed that berbamine was released from microspheres in a significantly sustained fashion.

  12. The physical and chemical stability of suspensions of sustained-release diclofenac microspheres.

    Science.gov (United States)

    Lewis, L; Boni, R L; Adeyeye, C M

    1998-01-01

    The major challenge in liquid sustained-release oral suspensions is to minimize drug diffusion into the suspending medium and to retain the original properties of the microparticles during storage. Diclofenac wax microspheres prepared by the hydrophobic congealable disperse phase method were formulated as a sustained release suspension and stored at three different temperatures (25, 37 and 45 degrees C) for 3 months, to evaluate the physical and chemical stability of the suspended microspheres. Suspensions of microspheres stored at ambient temperatures were both physically and chemically stable, but at higher temperatures, up to 45 degrees C, there was a decrease in drug release due to scaling and melting on the microsphere surface as observed by scanning electron microscopy. However, on prolonged storage, up to 90 days, especially at 45 degrees C, temperature became a dominant factor causing an increase in drug release. The suspension of diclofenac microspheres was chemically stable for 3 months, while the plain drug suspension exhibited slight degradation.

  13. Biomimetic composite microspheres of collagen/chitosan/nano-hydroxyapatite: In-situ synthesis and characterization.

    Science.gov (United States)

    Teng, Shu-Hua; Liang, Mian-Hui; Wang, Peng; Luo, Yong

    2016-01-01

    The collagen/chitosan/hydroxyapatite (COL/CS/HA) composite microspheres with a good spherical form and a high dispersity were successfully obtained using an in-situ synthesis method. The FT-IR and XRD results revealed that the inorganic phase in the microspheres was crystalline HA containing carbonate ions. The morphology of the composite microspheres was dependent on the HA content, and a more desirable morphology was achieved when 20 wt.% HA was contained. The composite microspheres exhibited a narrow particle distribution, most of which ranged from 5 to 10 μm. In addition, the needle-like HA nano-particles were uniformly distributed in the composite microspheres, and their crystallinity and crystal size decreased with the HA content. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Microspheres with an ultra high holmium content for brachytherapy of malignancies

    International Nuclear Information System (INIS)

    Lira, Raphael A.; Myamoto, Douglas M.; Souza, Jaime R.; Nascimento, Nanci; Azevedo, Mariangela de Burgos M. de; Osso Junior, Joao A.; Martinelli, Jose R.

    2011-01-01

    The overall objective of this work is to develop biodegradable microspheres intended for internal radiation therapy which provides an improved treatment for hepatic carcinomas. The most studied brachytherapy system employing microspheres made of holmium-biopolymer system is composed by poly(L-lactic acid) (PLLA) and holmium acetylacetonate (HoAcAc). The importance of the holmium high content in the microspheres can be interpreted as follow from a therapeutic standpoint, to achieve an effective use of microspheres loaded with HoAcAc, a high content of holmium is required to yield enough radioactivity with a relatively low amount of microspheres.The usual amounts of holmium that are incorporated in the microspheres composed by poly(L-lactic acid) and HoAcAc are 17.0 ± 0.5% (w/w) of holmium, which corresponds to a loading of about 50% of HoAcAc. Different approaches have been investigated to increase that value. One updated approach towards this direction is the production of microspheres with ultrahigh holmium as matrix using HoAcAc crystals as the sole starting material without the use of biopolymer. Likewise, in the search of microspheres with increased holmium content , it has been demonstrated that by changing the HoAcAc crystal structure by its recrystallization from crystal phase to the amorphous there is lost of acetylacetonate and water molecules causing the increasing of the holmium content. Microspheres were prepared by solvent evaporation, using holmium acetylacetonate (HoAcAc) crystals as the sole ingredient. Microspheres were characterized by using light and scanning electron microscopy, infrared and Raman spectroscopy, differential scanning calorimetry, X-rays diffraction, and confocal laser scanning microscopy. (author)

  15. Microspheres with an ultra high holmium content for brachytherapy of malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Lira, Raphael A.; Myamoto, Douglas M.; Souza, Jaime R.; Nascimento, Nanci; Azevedo, Mariangela de Burgos M. de [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Biotecnologia; Osso Junior, Joao A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Radiofarmacia; Martinelli, Jose R. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Ciencias e Tecnologia de Materiais

    2011-07-01

    The overall objective of this work is to develop biodegradable microspheres intended for internal radiation therapy which provides an improved treatment for hepatic carcinomas. The most studied brachytherapy system employing microspheres made of holmium-biopolymer system is composed by poly(L-lactic acid) (PLLA) and holmium acetylacetonate (HoAcAc). The importance of the holmium high content in the microspheres can be interpreted as follow from a therapeutic standpoint, to achieve an effective use of microspheres loaded with HoAcAc, a high content of holmium is required to yield enough radioactivity with a relatively low amount of microspheres.The usual amounts of holmium that are incorporated in the microspheres composed by poly(L-lactic acid) and HoAcAc are 17.0 {+-} 0.5% (w/w) of holmium, which corresponds to a loading of about 50% of HoAcAc. Different approaches have been investigated to increase that value. One updated approach towards this direction is the production of microspheres with ultrahigh holmium as matrix using HoAcAc crystals as the sole starting material without the use of biopolymer. Likewise, in the search of microspheres with increased holmium content , it has been demonstrated that by changing the HoAcAc crystal structure by its recrystallization from crystal phase to the amorphous there is lost of acetylacetonate and water molecules causing the increasing of the holmium content. Microspheres were prepared by solvent evaporation, using holmium acetylacetonate (HoAcAc) crystals as the sole ingredient. Microspheres were characterized by using light and scanning electron microscopy, infrared and Raman spectroscopy, differential scanning calorimetry, X-rays diffraction, and confocal laser scanning microscopy. (author)

  16. Covalently coating dextran on macroporous polyglycidyl methacrylate microsphere enabled rapid protein chromatographic separation

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Rongyue; Li, Qiang; Li, Juan; Zhou, Weiqing; Ye, Peili; Gao, Yang; Ma, Guanghui, E-mail: ghma@home.ipe.ac.cn; Su, Zhiguo

    2012-12-01

    Protein denaturation and nonspecific adsorption on polymer media as a chromatographic support have been a problem which needs to be overcome. Macroporous poly(glycidyl methacrylate-divinylbezene) (PGMA-DVB) microspheres prepared in this study were firstly covalently coated with dextran through a three-step method. The dextran was firstly adsorbed onto the microspheres and then covalently bound to the PGMA-DVB microsphere through ether bonds which were formed by hydroxyl group reacting with epoxy group at the presence of 4-(Dimethylamino) pyridine. Finally, the coating dextran layer was crosslinked by ethylene glycol diglycidyl ether to form the continuous network coating. The coated microspheres were characterized by Fourier transform infrared spectra, scanning electron microscope, mercury porosimetry measurements, laser scanning confocal microscope, and protein adsorption experiments. Results showed that PGMA-DVB microspheres coated with dextran successfully maintained the macroporous structure and high permeability. The backpressure was only 1.69 MPa at a high flow rate of 2891 cm/h. Consequently, the hydrophilicity and biocompatibility of modified microspheres were greatly improved, and the contact angle decreased from 184 Degree-Sign to 13 Degree-Sign , and nonspecific adsorption of proteins was decreased to little or none. The clad dextran coating with large amounts of hydroxyl group was easily derived to be various functional groups. The derived media have great potential applications in rapid protein chromatography. - Highlights: Black-Right-Pointing-Pointer Macroporous PGMA-DVB microspheres were covalently coated with dextran. Black-Right-Pointing-Pointer The hydrophilicity of the coated microspheres was significantly improved. Black-Right-Pointing-Pointer The irreversible adsorption of proteins was reduced to zero. Black-Right-Pointing-Pointer The coated microspheres can maintain the macropore structure. Black-Right-Pointing-Pointer The coated microspheres

  17. Covalently coating dextran on macroporous polyglycidyl methacrylate microsphere enabled rapid protein chromatographic separation

    International Nuclear Information System (INIS)

    Zhang, Rongyue; Li, Qiang; Li, Juan; Zhou, Weiqing; Ye, Peili; Gao, Yang; Ma, Guanghui; Su, Zhiguo

    2012-01-01

    Protein denaturation and nonspecific adsorption on polymer media as a chromatographic support have been a problem which needs to be overcome. Macroporous poly(glycidyl methacrylate–divinylbezene) (PGMA–DVB) microspheres prepared in this study were firstly covalently coated with dextran through a three-step method. The dextran was firstly adsorbed onto the microspheres and then covalently bound to the PGMA–DVB microsphere through ether bonds which were formed by hydroxyl group reacting with epoxy group at the presence of 4-(Dimethylamino) pyridine. Finally, the coating dextran layer was crosslinked by ethylene glycol diglycidyl ether to form the continuous network coating. The coated microspheres were characterized by Fourier transform infrared spectra, scanning electron microscope, mercury porosimetry measurements, laser scanning confocal microscope, and protein adsorption experiments. Results showed that PGMA–DVB microspheres coated with dextran successfully maintained the macroporous structure and high permeability. The backpressure was only 1.69 MPa at a high flow rate of 2891 cm/h. Consequently, the hydrophilicity and biocompatibility of modified microspheres were greatly improved, and the contact angle decreased from 184° to 13°, and nonspecific adsorption of proteins was decreased to little or none. The clad dextran coating with large amounts of hydroxyl group was easily derived to be various functional groups. The derived media have great potential applications in rapid protein chromatography. - Highlights: ► Macroporous PGMA–DVB microspheres were covalently coated with dextran. ► The hydrophilicity of the coated microspheres was significantly improved. ► The irreversible adsorption of proteins was reduced to zero. ► The coated microspheres can maintain the macropore structure. ► The coated microspheres were applied to rapid protein separation.

  18. Formulation and characterization of ketoprofen embedded polycaprolactone microspheres using solvent evaporation method

    Directory of Open Access Journals (Sweden)

    Pankaj Wagh

    2015-07-01

    Full Text Available The purpose of this study was to prepare polymeric microspheres containing Ketoprofen (KFN by single emulsion [oil-in-water (o/w] solvent evaporation method. Polycaprolactone (PCL, biocompatible polymer, was used for the preparation of sustained released microspheres of KFN. A Plackett–Burman design was employed by using the Design-Expert® software (Version- 9.0.3.1, Stat-Ease Inc., Minneapolis, MN. Eleven factors out of six processing factors were investigated in order to enhance the encapsulation efficiency (EE of the microspheres. The resultant microspheres were characterized for their size, morphology, EE, and drug release. Imaging of particles was performed by field emission scanning electron microscopy. Interaction between the drug and polymers were investigated by Fourier transform infrared (FTIR spectroscopy, X-ray powder diffractometry (XRPD and Differential Scanning Calorimetry (DSC. Graphical and mathematical analyses of the design showed that concentration of factor PCL (B and varying speed (F, revolution per minute, rpm were significant negative effect on the EE and identified as the significant factor determining the EE of the microspheres. The microspheres showed high % EE (31.18 % to 96.81 %. The microspheres were found to be discrete, oval with porous surface. The FTIR analysis confirmed no interaction of KFN with the polymer. The XRPD revealed the dispersion of drug within microspheres formulation. Sustained drug release profile over 12 h was achieved by PCL polymer. In conclusion, polymeric microspheres containing KFN can be successfully prepared using the technique of experimental design, and these results helped in finding the optimum formulation variables for EE of microspheres.

  19. [Preparation of citrulline microspheres by spray drying technique for colonic targeting].

    Science.gov (United States)

    Bahri, S; Zerrouk, N; Lassoued, M-A; Tsapis, N; Chaumeil, J-C; Sfar, S

    2014-03-01

    Citrulline is an amino acid that becomes essential in situations of intestinal insufficiency such as short bowel syndrome. It is therefore interesting to provide the patients with dosage forms for routing citrulline to the colon. The aim of this work is to formulate microspheres of citrulline for colonic targeting by the technique of spray drying. Eudragit(®) FS 30D was selected as polymer to encapsulate citrulline using the spray drying technique. Citrulline and Eudragit(®) FS 30D were dissolved in water and ethanol, respectively. The aqueous and the ethanolic solutions were then mixed in 1:2 (v/v) ratio. Microspheres were obtained by nebulizing the citrulline-Eudragit(®) FS 30D solution using a Mini spray dryer equipped with a 0.7mm nozzle. The microspheres have been formulated using citrulline and Eudragit(®) FS 30D. The size distribution of microspheres was determined by light diffraction. The morphology of the microspheres was studied by electron microscopy. Manufacturing yields, encapsulation rate and dissolution profiles were also studied. The microspheres obtained had a spherical shape with a smooth surface and a homogeneous size except for the microspheres containing the highest concentration of polymer (90 %). The formulation showed that the size and morphology of the microspheres are influenced by the polymer concentration. Manufacturing yields were about 51 % but encapsulation rate were always very high (above 90 %). The in vitro dissolution study showed that the use of the Eudragit(®) FS 30D under these conditions is not appropriate to change the dissolution profile of the citrulline. This technique has led to the formulation of microspheres with good physical properties in terms of morphology and size. The compression of the microspheres should help to control citrulline release for colonic targeting. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  20. Development and optimization of enteric coated mucoadhesive microspheres of duloxetine hydrochloride using 32 full factorial design

    Science.gov (United States)

    Setia, Anupama; Kansal, Sahil; Goyal, Naveen

    2013-01-01

    Background: Microspheres constitute an important part of oral drug delivery system by virtue of their small size and efficient carrier capacity. However, the success of these microspheres is limited due to their short residence time at the site of absorption. Objective: The objective of the present study was to formulate and systematically evaluate in vitro performance of enteric coated mucoadhesive microspheres of duloxetine hydrochloride (DLX), an acid labile drug. Materials and Methods: DLX microspheres were prepared by simple emulsification phase separation technique using chitosan as carrier and glutaraldehyde as a cross-linking agent. Microspheres prepared were coated with eudragit L-100 using an oil-in-oil solvent evaporation method. Eudragit L-100was used as enteric coating polymer with the aim to release the drug in small intestine The microspheres prepared were characterized by particle size, entrapment efficiency, swelling index (SI), mucoadhesion time, in vitro drug release and surface morphology. A 32 full factorial design was employed to study the effect of independent variables polymer-to-drug ratio (X1) and stirring speed (X2) on dependent variables, particle size, entrapment efficiency, SI, in vitro mucoadhesion and drug release up to 24 h (t24). Results: Microspheres formed were discrete, spherical and free flowing. The microspheres exhibited good mucoadhesive property and also showed high percentage entrapment efficiency. The microspheres were able to sustain the drug release up to 24 h. Conclusion: Thus, the prepared enteric coated mucoadhesive microspheres may prove to be a potential controlled release formulation of DLX for oral administration. PMID:24167786

  1. Preparation of Polysaccharide-Based Microspheres by a Water-in-Oil Emulsion Solvent Diffusion Method for Drug Carriers

    Directory of Open Access Journals (Sweden)

    Yodthong Baimark

    2013-01-01

    Full Text Available Polysaccharide-based microspheres of chitosan, starch, and alginate were prepared by the water-in-oil emulsion solvent diffusion method for use as drug carriers. Blue dextran was used as a water-soluble biomacromolecular drug model. Scanning electron microscopy showed sizes of the resultant microspheres that were approximately 100 μm or less. They were spherical in shape with a rough surface and good dispersibility. Microsphere matrices were shown as a sponge. Drug loading efficiencies of all the microspheres were higher than 80%, which suggested that this method has potential to prepare polysaccharide-based microspheres containing a biomacromolecular drug model for drug delivery applications.

  2. Design of sustained-release nitrendipine microspheres having solid dispersion structure by quasi-emulsion solvent diffusion method

    DEFF Research Database (Denmark)

    Cui, Fude; Yang, Mingshi; Jiang, Yanyan

    2003-01-01

    crystallization technique, i.e. quasi-emulsion solvent diffusion method. The factors of effect on micromeritic properties and release profiles of the resultant microspheres were investigated. And the bioavailability of nitrendipine microspheres was evaluated in six healthy dogs. The results showed...... that the particle size of microspheres was determined mainly by the agitation speed. The dissolution rate of nitrendipine from microspheres was enhanced significantly with increasing the amount of dispersing agents, and sustained by adding retarding agents. The release rate of microspheres could be controlled...

  3. Strain-tuned optoelectronic properties of hollow gallium sulphide microspheres

    Science.gov (United States)

    Zhang, Yin; Chen, Chen; Liang, C. Y.; Liu, Z. W.; Li, Y. S.; Che, Renchao

    2015-10-01

    Sulfide semiconductors have attracted considerable attention. The main challenge is to prepare materials with a designable morphology, a controllable band structure and optoelectronic properties. Herein, we report a facile chemical transportation reaction for the synthesis of Ga2S3 microspheres with novel hollow morphologies and partially filled volumes. Even without any extrinsic dopant, photoluminescence (PL) emission wavelength could be facilely tuned from 635 to 665 nm, depending on its intrinsic inhomogeneous strain distribution. Geometric phase analysis (GPA) based on high-resolution transmission electron microscopy (HRTEM) imaging reveals that the strain distribution and the associated PL properties can be accurately controlled by changing the growth temperature gradient, which depends on the distance between the boats used for raw material evaporation and microsphere deposition. The stacking-fault density, lattice distortion degree and strain distribution at the shell interfacial region of the Ga2S3 microspheres could be readily adjusted. Ab initio first-principles calculations confirm that the lowest conductive band (LCB) is dominated by S-3s and Ga-4p states, which shift to the low-energy band as a result of the introduction of tensile strain, well in accordance with the observed PL evolution. Therefore, based on our strain driving strategy, novel guidelines toward the reasonable design of sulfide semiconductors with tunable photoluminescence properties are proposed.Sulfide semiconductors have attracted considerable attention. The main challenge is to prepare materials with a designable morphology, a controllable band structure and optoelectronic properties. Herein, we report a facile chemical transportation reaction for the synthesis of Ga2S3 microspheres with novel hollow morphologies and partially filled volumes. Even without any extrinsic dopant, photoluminescence (PL) emission wavelength could be facilely tuned from 635 to 665 nm, depending on its

  4. Preparation of Syndiotactic Poly(vinyl alcohol)/Poly(vinyl pivalate/vinyl acetate) Microspheres with Radiopacity Using Suspension Copolymerization and Saponification

    Science.gov (United States)

    Seok Lyoo, Won; Wook Cha, Jin; Young Kwak, Kun; Jae Lee, Young; Yong Jeon, Han; Sik Chung, Yong; Kyun Noh, Seok

    2010-06-01

    To prepare Poly(vinyl pivalate/vinyl acetate) [P(VPi/VAc)] microspheres with radiopacity, the suspension copolymerization approach in the presence of aqueous radiopaque nanoparticles was used. After, The P(VPi/VAc) microspheres with radiopacity were saponified in heterogeneous system, and then P(VPi/VAc) microspheres without aggregates were converted to s-PVA/P(VPi/VAc) microspheres of skin/core structure through the heterogeneous surface saponification. Radiopacity of microspheres was confirmed with Computed tomography (CT).

  5. Microsphere preparation using highly branched dextran degraded by electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Min Ho; Yoo, Sun Kyun [Joongbu Univ., Geumsan (Korea, Republic of); Kang, Hyun Suk; Lee, Byung Cheol [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-07-01

    Dextrans as noble alternative consist predominantly of linear a-1,6 glucose linkages with some degree of branching via 1,2-, 1,3-, or 1,4- linkage. Dextrans have been investigated as potential macromolecular carriers for delivery of drugs and proteins, primarily to increase the longevity of therapeutic agents in the delivery of drugs and proteins, primarily to increase the longevity of therapeutic agents in the circulation. In most previous researches, linear type of dextrans with molecular weight of new type of drug delivery agent. Since 1950, the clinical dextran has been manufactured by acid hydrolysis, of which processes are multi-steps and time-consumed. Therefore, the objective of this research is evaluate the microsphere synthesised by highly branched dextran degraded by a electron beam radiation. Linear type of dextran was purchased from Sigma company. Branch type of dextran was produced and purified in our lab. The branch degree of dextran was evaluated using dextranase and analyzed by TLC. The air-dry dextran and two solution dextran was irradiated at room temperature using a electrostatic beam. The electron beam energy applied was 1.0 to 2.5 MeV. Dose was 70 kGy. The molecular average weight if 11,215,000 of linear dextran and 7,413,000 was degraded to 213,000 and 112,000, respectively. Branched dextran applied by a beam still retained its branched structure. The size of microsphere was dependant of the amount of PPG added to make water to water emulsion. Swelling of microsphere of branched dextran was higher than of linear dextran.

  6. Microsphere preparation using highly branched dextran degraded by electron beam

    International Nuclear Information System (INIS)

    Oh, Min Ho; Yoo, Sun Kyun; Kang, Hyun Suk; Lee, Byung Cheol

    2011-01-01

    Dextrans as noble alternative consist predominantly of linear a-1,6 glucose linkages with some degree of branching via 1,2-, 1,3-, or 1,4- linkage. Dextrans have been investigated as potential macromolecular carriers for delivery of drugs and proteins, primarily to increase the longevity of therapeutic agents in the delivery of drugs and proteins, primarily to increase the longevity of therapeutic agents in the circulation. In most previous researches, linear type of dextrans with molecular weight of new type of drug delivery agent. Since 1950, the clinical dextran has been manufactured by acid hydrolysis, of which processes are multi-steps and time-consumed. Therefore, the objective of this research is evaluate the microsphere synthesised by highly branched dextran degraded by a electron beam radiation. Linear type of dextran was purchased from Sigma company. Branch type of dextran was produced and purified in our lab. The branch degree of dextran was evaluated using dextranase and analyzed by TLC. The air-dry dextran and two solution dextran was irradiated at room temperature using a electrostatic beam. The electron beam energy applied was 1.0 to 2.5 MeV. Dose was 70 kGy. The molecular average weight if 11,215,000 of linear dextran and 7,413,000 was degraded to 213,000 and 112,000, respectively. Branched dextran applied by a beam still retained its branched structure. The size of microsphere was dependant of the amount of PPG added to make water to water emulsion. Swelling of microsphere of branched dextran was higher than of linear dextran

  7. Trapping of a microsphere pendulum resonator in an optical potential

    International Nuclear Information System (INIS)

    Ward, J. M.; Wu, Y.; Nic Chormaic, S.; Minogin, V. G.

    2009-01-01

    We propose a method to spatially confine or corral the movements of a micropendulum via the optical forces produced by two simultaneously excited optical modes of a photonic molecule comprising two microspherical cavities. We discuss how the cavity-enhanced optical force generated in the photonic molecule can create an optomechanical potential of about 10 eV deep and 30 pm wide, which can be used to trap the pendulum at any given equilibrium position by a simple choice of laser frequencies. This result presents opportunities for very precise all-optical self-alignment of microsystems.

  8. Magnetic Ganoderma lucidum spore microspheres: A novel material to immobilize CotA multicopper oxidase for dye decolorization

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Lili [School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin 150001 (China); Wang, Yan, E-mail: wangy_msn@hit.edu.cn [School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin 150001 (China); Zhao, Min [College of Life Science, Northeast Forestry University, Harbin 150040 (China); Song, Jinzhu [School of Life Science and Technology, Harbin Institute of Technology, Harbin 150001 (China); Wang, Jueyu; Jin, Zijing [College of Life Science, Northeast Forestry University, Harbin 150040 (China)

    2016-08-05

    Highlights: • Hollow microspheres were obtained from Ganoderma lucidum spores. • Novel magnetic microspheres were prepared by load hollow spore microspheres with Fe{sub 3}O{sub 4} nanoparticles. • CotA multicopper oxidase was immobilized on the magnetic spore microspheres for indigo carmine decolorization. • The immobilized CotA displayed higher decolorization capability and reusability. - Abstract: In this study, hollow microspheres were obtained from Ganoderma lucidum spores. Then the hollow microspheres were loaded with Fe{sub 3}O{sub 4} nanoparticles to prepare novel magnetic spore microspheres. TEM images and X-ray diffractometry demonstrated that the Fe{sub 3}O{sub 4} nanoparticles were incorporated throughout the spore microsphere. CotA multicopper oxidase was chosen as biomacromolecule to study the loading ability of the magnetic spore microspheres. The combination of the CotA enzyme with the microsphere was observed by laser scanning confocal microscope. The loaded amount of CotA on the microspheres was 75 mg/g when the CotA concentration was 1.2 mg/mL and the activity recovery of the immobilized CotA was 81%. The magnetic microspheres loaded with CotA, which can be easily and quickly recovered by an external magnetic field, were used for dye decolorization. After 1 h decolorization, 99% of the indigo carmine has been removed by 10 mg microspheres. In addition, the immobilized CotA retained 75% of activity after 10 consecutive cycles, which indicated that the magnetic spore microspheres are good support material for immobilization of the enzyme.

  9. Magnetic Ganoderma lucidum spore microspheres: A novel material to immobilize CotA multicopper oxidase for dye decolorization

    International Nuclear Information System (INIS)

    Fan, Lili; Wang, Yan; Zhao, Min; Song, Jinzhu; Wang, Jueyu; Jin, Zijing

    2016-01-01

    Highlights: • Hollow microspheres were obtained from Ganoderma lucidum spores. • Novel magnetic microspheres were prepared by load hollow spore microspheres with Fe_3O_4 nanoparticles. • CotA multicopper oxidase was immobilized on the magnetic spore microspheres for indigo carmine decolorization. • The immobilized CotA displayed higher decolorization capability and reusability. - Abstract: In this study, hollow microspheres were obtained from Ganoderma lucidum spores. Then the hollow microspheres were loaded with Fe_3O_4 nanoparticles to prepare novel magnetic spore microspheres. TEM images and X-ray diffractometry demonstrated that the Fe_3O_4 nanoparticles were incorporated throughout the spore microsphere. CotA multicopper oxidase was chosen as biomacromolecule to study the loading ability of the magnetic spore microspheres. The combination of the CotA enzyme with the microsphere was observed by laser scanning confocal microscope. The loaded amount of CotA on the microspheres was 75 mg/g when the CotA concentration was 1.2 mg/mL and the activity recovery of the immobilized CotA was 81%. The magnetic microspheres loaded with CotA, which can be easily and quickly recovered by an external magnetic field, were used for dye decolorization. After 1 h decolorization, 99% of the indigo carmine has been removed by 10 mg microspheres. In addition, the immobilized CotA retained 75% of activity after 10 consecutive cycles, which indicated that the magnetic spore microspheres are good support material for immobilization of the enzyme.

  10. Preparation of hollow hydroxyapatite microspheres by the conversion of borate glass at near room temperature

    International Nuclear Information System (INIS)

    Yao, Aihua; Ai, Fanrong; Liu, Xin; Wang, Deping; Huang, Wenhai; Xu, Wei

    2010-01-01

    Hollow hydroxyapatite microspheres, consisting of a hollow core and a porous shell, were prepared by converting Li 2 O-CaO-B 2 O 3 glass microspheres in dilute phosphate solution at 37 o C. The results confirmed that Li 2 O-CaO-B 2 O 3 glass was transformed to hydroxyapatite without changing the external shape and dimension of the original glass object. Scanning electron microscopy images showed the shell wall of the microsphere was built from hydroxyapatite particles, and these particles spontaneously align with one another to form a porous sphere with an interior cavity. Increase in phosphate concentration resulted in an increase in the reaction rate, which in turn had an effect on shell wall structure of the hollow hydroxyapatite microsphere. For the Li 2 O-CaO-B 2 O 3 glass microspheres reacted in low-concentration K 2 HPO 4 solution, lower reaction rate and a multilayered microstructure were observed. On the other hand, the glass microspheres reacted in higher phosphate solution converted more rapidly and produced a single hydroxyapatite layer. Furthermore, the mechanism of forming hydroxyapatite hollow microsphere was described.

  11. Performance evaluation of bipolar and tripolar excitations during nozzle-jetting-based alginate microsphere fabrication

    Science.gov (United States)

    Herran, C. Leigh; Huang, Yong; Chai, Wenxuan

    2012-08-01

    Microspheres, small spherical (polymeric) particles with or without second phase materials embedded or encapsulated, are important for many biomedical applications such as drug delivery and organ printing. Scale-up fabrication with the ability to precisely control the microsphere size and morphology has always been of great manufacturing interest. The objective of this work is to experimentally study the performance differences of bipolar and tripolar excitation waveforms in using drop-on-demand (DOD)-based single nozzle jetting for alginate microsphere fabrication. The fabrication performance has been evaluated based on the formability of alginate microspheres as a function of materials properties (sodium alginate and calcium chloride concentrations) and operating conditions. The operating conditions for each excitation include voltage rise/fall times, dwell times and excitation voltage amplitudes. Overall, the bipolar excitation is more robust in making spherical, monodispersed alginate microspheres as good microspheres for its wide working range of material properties and operating conditions, especially during the fabrication of highly viscous materials such as the 2% sodium alginate solution. For both bipolar and tripolar excitations, the sodium alginate concentration and the voltage dwell times should be carefully selected to achieve good microsphere formability.

  12. Performance evaluation of bipolar and tripolar excitations during nozzle-jetting-based alginate microsphere fabrication

    International Nuclear Information System (INIS)

    Leigh Herran, C; Huang, Yong; Chai, Wenxuan

    2012-01-01

    Microspheres, small spherical (polymeric) particles with or without second phase materials embedded or encapsulated, are important for many biomedical applications such as drug delivery and organ printing. Scale-up fabrication with the ability to precisely control the microsphere size and morphology has always been of great manufacturing interest. The objective of this work is to experimentally study the performance differences of bipolar and tripolar excitation waveforms in using drop-on-demand (DOD)-based single nozzle jetting for alginate microsphere fabrication. The fabrication performance has been evaluated based on the formability of alginate microspheres as a function of materials properties (sodium alginate and calcium chloride concentrations) and operating conditions. The operating conditions for each excitation include voltage rise/fall times, dwell times and excitation voltage amplitudes. Overall, the bipolar excitation is more robust in making spherical, monodispersed alginate microspheres as good microspheres for its wide working range of material properties and operating conditions, especially during the fabrication of highly viscous materials such as the 2% sodium alginate solution. For both bipolar and tripolar excitations, the sodium alginate concentration and the voltage dwell times should be carefully selected to achieve good microsphere formability. (paper)

  13. A novel approach to preparing magnetic protein microspheres with core-shell structure

    International Nuclear Information System (INIS)

    Jiang Wei; Sun Zhendong; Li Fengsheng; Chen Kai; Liu Tianyu; Liu Jialing; Zhou Tianle; Guo Rui

    2011-01-01

    Magnetic protein microspheres with core-shell structure were prepared through a novel approach based on the sonochemical method and the emulsion solvent evaporation method. The microspheres are composed of the oleic acid and undecylenic acid modified Fe 3 O 4 cores and coated with globular bovine serum albumin (BSA). Under an optimized condition, up to 57.8 wt% of approximately 10 nm superparamagnetic Fe 3 O 4 nanoparticles could be uniformly encapsulated into the BSA microspheres with the diameter of approximately 160 nm and the high saturation magnetization of 38.5 emu/g, besides of the abundant functional groups. The possible formation mechanism of magnetic microspheres was discussed in detail. - Research Highlights: → Magnetic protein microspheres with core-shell structure were prepared through a novel approach based on the sonochemical method and the emulsion solvent evaporation method.→ The microspheres are composed of the oleic acid and undecylenic acid modified Fe 3 O 4 cores and coated with globular bovine serum albumin (BSA).→ 57.8 wt% of approximately 10 nm superparamagnetic Fe 3 O 4 nanoparticles could be uniformly encapsulated into the BSA microspheres with the diameter of approximately 160 nm and the high saturation magnetization of 38.5 emu/g, besides the abundant functional groups.

  14. Transmission electron microscopy and Raman characterization of copper (I) oxide microspheres composed of nanoparticles

    International Nuclear Information System (INIS)

    Wang Wenzhong; Tu Ya; Wang Lijuan; Liang Yujie; Shi Honglong

    2013-01-01

    Highlights: ► Raman spectroscopy of copper (I) oxide microspheres were investigated. ► Infrared active mode is greatly activated in Raman scattering spectrum. ► Infrared active mode shows up in Raman spectrum of copper (I) oxide microspheres. ► The defects existed in spheres could be responsible for the observed Raman property. - Abstract: The high-resolution transmission electron microscope and Raman spectroscopy were used to investigate the microstructures and Raman scattering property of copper (I) oxide microspheres composed of nanoparticles. High-resolution transmission electron microscope images indicate that the copper (I) oxide microspheres are composed of nanoparticles with random growth direction, indicating that there are many defects in microspheres. The Raman spectrum shows that infrared active mode, which must be odd parity and is Raman forbidden for bulk crystal due to its inversion symmetry, is activated and shows up in Raman scattering spectrum. On the basis of investigations of the microstructure features of copper (I) oxide microspheres, we attribute the appearance of IR active mode in Raman scattering spectrum to the breakdown of the symmetry of the lattice due to the presence of defects in the prepared copper (I) oxide microspheres as observed in HRTEM images.

  15. Synthesis and effect of modification on methacylate - acrylate microspheres for Trametes versicolor laccase enzyme immobilization

    Science.gov (United States)

    Mazlan, Siti Zulaikha; Hanifah, Sharina Abu

    2014-09-01

    Immobilization of laccase on the modified copolymer methacrylate-acrylate microspheres was studied. A poly (glycidyl methacrylate-co-n-butyl acrylate) microsphere consists of epoxy groups were synthesized using suspension photocuring technique. The epoxy group in poly (GMA-nBA) microspheres were converted into amino groups with aldehyde group. Laccase immobilization is based on having the amino groups on the enzyme surface and aldehyde group on the microspheres via covalent binding. Fourier transform infrared spectroscopy (FT-IR) analysis proved the successful surface modification on microspheres. The FTIR spectrum shows the characteristic peaks at 1646 cm-1 assigned to the conformation of the polymerization that took place between monomer GMA and nBA respectively. In addition, after modification, FTIR peaks that assigned to the epoxy ring (844 cm-1 and 904 cm-1) were decreased. The results obtained from FTIR method signify good agreement with the epoxy content method. Hence, the activity of the laccase-immobilized microspheres increased upon increasing the epoxy content. Furthermore, poly (GMA-nBA) exhibited uniform microspheres with below 2 μm surface. Immobilized enzyme showed a broader pH profile and higher temperature compared native enzyme.

  16. Ammonolysis-induced solvent removal: a facile approach for solidifying emulsion droplets into PLGA microspheres.

    Science.gov (United States)

    Kim, Jayoung; Hong, Dasom; Chung, Younglim; Sah, Hongkee

    2007-12-01

    An ammonolysis-based microencapsulation technique useful for the preparation of biodegradable microspheres was described in this study. A dispersed phase consisting of poly- d, l-lactide- co-glycolide, progesterone, and methyl chloroacetate was emulsified in an aqueous phase. Upon addition of ammonia solution, the emulsion droplets were quickly transformed into poly- d, l-lactide- co-glycolide microspheres laden with progesterone. Rapid solvent removal was accompanied by ammonolysis. The chemical reaction converted water-immiscible methyl chloroacetate to water-miscible chloroacetamide and methanol. Chloroacetamide formation was proved by (1)H NMR and ESI-MS studies. Thermogravimetric analysis showed that the microspheres contained only small amounts of residual methyl chloroacetate. Incorporation efficiencies of progesterone ranged from 64.3 +/- 1.1 to 72.8 +/- 0.3%, depending upon microsphere formulations. X-ray powder diffractometry analysis substantiated that no polymorphic transition of progesterone occurred during microencapsulation. To evaluate the feasibility of this new method against the commonly used microencapsulation method, microspheres were also prepared by a typical dichloromethane-based solvent evaporation process. The important attributes of microspheres prepared from both methods were characterized for comparison. The new ammonolysis-based microencapsulation process showed interesting features distinct from those of the solvent evaporation process. The microencapsulation process reported in this study might be applicable in loading pharmaceuticals into various polymeric microspheres.

  17. Microwave Irradiation Assisted Preparation of Chitosan Composite Microsphere for Dye Adsorption

    Directory of Open Access Journals (Sweden)

    Xiaoyu Chen

    2017-01-01

    Full Text Available Chitosan-activated carbon composite microspheres were prepared by emulsion cross-linking method and its adsorption properties for methyl orange were studied. Chitosan solution was mixed with activated carbon powder and then chitosan was cross-linked by epichlorohydrin under microwave irradiation. SEM photos show that the composite microspheres have diameters of 200–400 μm and activated carbon powder dispersed on the surface of composite microsphere. FTIR spectrum indicates chitosan is successfully cross-linked. Microwave irradiation can effectively shorten the cross-linking time. Composite microspheres have enhanced dye adsorption capacity for methyl orange compared to chitosan microspheres. Kinetic studies showed that the adsorption followed a pseudo-second-order model. Isotherm studies show that the isotherm adsorption equilibrium is better described by Freundlich isotherm. Regeneration results show that adsorption capacity of composite microsphere decreased about 5.51% after being reused for three times. These results indicated that chitosan-activated carbon composite microsphere has potential application in the removal of dye from wastewaters.

  18. A novel approach to preparing magnetic protein microspheres with core-shell structure

    Energy Technology Data Exchange (ETDEWEB)

    Jiang Wei, E-mail: climentjw@126.co [National Special Superfine Powder Engineering Research Center, Nanjing University of Science and Technology, Nanjing 210094 (China); Sun Zhendong; Li Fengsheng [National Special Superfine Powder Engineering Research Center, Nanjing University of Science and Technology, Nanjing 210094 (China); Chen Kai; Liu Tianyu; Liu Jialing [Department of Physics, Nanjing University of Science and Technology, Nanjing 210094 (China); Zhou Tianle [Department of Materials Science and Engineering, Nanjing University of Science and Technology, Nanjing 210094 (China); Guo Rui [Department of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094 (China)

    2011-03-15

    Magnetic protein microspheres with core-shell structure were prepared through a novel approach based on the sonochemical method and the emulsion solvent evaporation method. The microspheres are composed of the oleic acid and undecylenic acid modified Fe{sub 3}O{sub 4} cores and coated with globular bovine serum albumin (BSA). Under an optimized condition, up to 57.8 wt% of approximately 10 nm superparamagnetic Fe{sub 3}O{sub 4} nanoparticles could be uniformly encapsulated into the BSA microspheres with the diameter of approximately 160 nm and the high saturation magnetization of 38.5 emu/g, besides of the abundant functional groups. The possible formation mechanism of magnetic microspheres was discussed in detail. - Research Highlights: Magnetic protein microspheres with core-shell structure were prepared through a novel approach based on the sonochemical method and the emulsion solvent evaporation method. The microspheres are composed of the oleic acid and undecylenic acid modified Fe{sub 3}O{sub 4} cores and coated with globular bovine serum albumin (BSA). 57.8 wt% of approximately 10 nm superparamagnetic Fe{sub 3}O{sub 4} nanoparticles could be uniformly encapsulated into the BSA microspheres with the diameter of approximately 160 nm and the high saturation magnetization of 38.5 emu/g, besides the abundant functional groups.

  19. Comparative assessment of in vitro release kinetics of calcitonin polypeptide from biodegradable microspheres.

    Science.gov (United States)

    Prabhu, Sunil; Sullivan, Jennifer L; Betageri, Guru V

    2002-01-01

    The objective of our study was to compare the in vitro release kinetics of a sustained-release injectable microsphere formulation of the polypeptide drug, calcitonin (CT), to optimize the characteristics of drug release from poly-(lactide-co-glycolide) (PLGA) copolymer biodegradable microspheres. A modified solvent evaporation and double emulsion technique was used to prepare the microspheres. Release kinetic studies were carried out in silanized tubes and dialysis bags, whereby microspheres were suspended and incubated in phosphate buffered saline, sampled at fixed intervals, and analyzed for drug content using a modified Lowry protein assay procedure. An initial burst was observed whereby about 50% of the total dose of the drug was released from the microspheres within 24 hr and 75% within 3 days. This was followed by a period of slow release over a period of 3 weeks in which another 10-15% of drug was released. Drug release from the dialysis bags was more gradual, and 50% CT was released only after 4 days and 75% after 12 days of release. Scanning electron micrographs revealed spherical particles with channel-like structures and a porous surface after being suspended in an aqueous solution for 5 days. Differential scanning calorimetric studies revealed that CT was present as a mix of amorphous and crystalline forms within the microspheres. Overall, these studies demonstrated that sustained release of CT from PLGA microspheres over a 3-week period is feasible and that release of drug from dialysis bags was more predictable than from tubes.

  20. Application of superparamagnetic microspheres for affinity adsorption and purification of glutathione

    International Nuclear Information System (INIS)

    Wang Qiang; Guan Yueping; Yang Mingzhu

    2012-01-01

    The superparamagnetic poly-(MA–DVB) microspheres with micron size were synthesized by the modified suspension polymerization method. Adsorption of glutathione by magnetic poly-(MA–DVB) microspheres with IDA-copper was investigated. The effect of solution pH value, affinity adsorption and desorption of glutathione was studied. The results showed that the optimum pH value for glutathione adsorption was found at pH=3.5, the maximum capacity for glutathione of magnetic poly-(MA–DVB) microspheres was estimated at 42.4 mg/g by fitting the experimental data to the Langmuir equation. The adsorption equilibrium of glutathione was obtained in about 10 min and the adsorbed glutathione was desorbed from the magnetic microspheres in about 30 min using NaCl buffer solution. The magnetic microspheres could be repeatedly utilized for the affinity adsorption of glutathione. - Highlights: ► The magnetic microsphere with surface IDA–Cu groups was synthesized. ► The magnetic microspheres were applied for adsorption of GSH. ► The adsorption–desorption of glutathione was investigated. ► The maximum adsorption capacity of GSH was fitted at 42.4 mg/g.

  1. Facile Synthesis of Mono-Dispersed Polystyrene (PS/Ag Composite Microspheres via Modified Chemical Reduction

    Directory of Open Access Journals (Sweden)

    Wen Zhu

    2013-12-01

    Full Text Available A modified method based on in situ chemical reduction was developed to prepare mono-dispersed polystyrene/silver (PS/Ag composite microspheres. In this approach; mono-dispersed PS microspheres were synthesized through dispersion polymerization using poly-vinylpyrrolidone (PVP as a dispersant at first. Then, poly-dopamine (PDA was fabricated to functionally modify the surfaces of PS microspheres. With the addition of [Ag(NH32]+ to the PS dispersion, [Ag(NH32]+ complex ions were absorbed and reduced to silver nanoparticles on the surfaces of PS-PDA microspheres to form PS/Ag composite microspheres. PVP acted both as a solvent of the metallic precursor and as a reducing agent. PDA also acted both as a chemical protocol to immobilize the silver nanoparticles at the PS surface and as a reducing agent. Therefore, no additional reducing agents were needed. The resulting composite microspheres were characterized by TEM, field emission scanning electron microscopy (FESEM, energy-dispersive X-ray spectroscopy (EDS, XRD, UV-Vis and surface-enhanced Raman spectroscopy (SERS. The results showed that Ag nanoparticles (NPs were homogeneously immobilized onto the PS microspheres’ surface in the presence of PDA and PVP. PS/Ag composite microspheres were well formed with a uniform and compact shell layer and were adjustable in terms of their optical property.

  2. Polymer blends used to develop felodipine-loaded hollow microspheres for improved oral bioavailability.

    Science.gov (United States)

    Pi, Chao; Feng, Ting; Liang, Jing; Liu, Hao; Huang, Dongmei; Zhan, Chenglin; Yuan, Jiyuan; Lee, Robert J; Zhao, Ling; Wei, Yumeng

    2018-06-01

    Felodipine (FD) has been widely used in anti-hypertensive treatment. However, it has extremely low aqueous solubility and poor bioavailability. To address these problems, FD hollow microspheres as multiple-unit dosage forms were synthesized by a solvent diffusion evaporation method. Particle size of the hollow microspheres, types of ethylcellulose (EC), amounts of EC, polyvinyl pyrrolidone (PVP) and FD were investigated based on an orthogonal experiment of three factors and three levels. In addition, the release kinetics in vitro and pharmacokinetics in beagle dogs of the optimized FD hollow microspheres was investigated and compared with Plendil (commercial FD sustained-release tablets) as a single-unit dosage form. Results showed that the optimal formulation was composed of EC 10 cp :PVP:FD (0.9:0.16:0.36, w/w). The FD hollow microspheres were globular with a hollow structure and have high drug loading (17.69±0.44%) and floating rate (93.82±4.05%) in simulated human gastric fluid after 24h. Pharmacokinetic data showed that FD hollow microspheres exhibited sustained-release behavior and significantly improved relative bioavailability of FD compared with the control. Pharmacodynamic study showed that the FD hollow microspheres could effectively lower blood pressure. Therefore, these findings demonstrated that the hollow microspheres were an effective sustained-release delivery system for FD. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Controlled Release of Lysozyme from Double-Walled Poly(Lactide-Co-Glycolide (PLGA Microspheres

    Directory of Open Access Journals (Sweden)

    Rezaul H. Ansary

    2017-10-01

    Full Text Available Double-walled microspheres based on poly(lactide-co-glycolide (PLGA are potential delivery systems for reducing a very high initial burst release of encapsulated protein and peptide drugs. In this study, double-walled microspheres made of glucose core, hydroxyl-terminated poly(lactide-co-glycolide (Glu-PLGA, and carboxyl-terminated PLGA were fabricated using a modified water-in-oil-in-oil-in-water (w1/o/o/w2 emulsion solvent evaporation technique for the controlled release of a model protein, lysozyme. Microspheres size, morphology, encapsulation efficiency, lysozyme in vitro release profiles, bioactivity, and structural integrity, were evaluated. Scanning electron microscopy (SEM images revealed that double-walled microspheres comprising of Glu-PLGA and PLGA with a mass ratio of 1:1 have a spherical shape and smooth surfaces. A statistically significant increase in the encapsulation efficiency (82.52% ± 3.28% was achieved when 1% (w/v polyvinyl alcohol (PVA and 2.5% (w/v trehalose were incorporated in the internal and external aqueous phase, respectively, during emulsification. Double-walled microspheres prepared together with excipients (PVA and trehalose showed a better control release of lysozyme. The released lysozyme was fully bioactive, and its structural integrity was slightly affected during microspheres fabrication and in vitro release studies. Therefore, double-walled microspheres made of Glu-PLGA and PLGA together with excipients (PVA and trehalose provide a controlled and sustained release for lysozyme.

  4. Preoperational test report, recirculation ventilation systems

    International Nuclear Information System (INIS)

    Clifton, F.T.

    1997-01-01

    This represents a preoperational test report for Recirculation Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides vapor space cooling of tanks AY1O1, AY102, AZ1O1, AZ102 and supports the ability to exhaust air from each tank. Each system consists of a valved piping loop, a fan, condenser, and moisture separator; equipment is located inside each respective tank farm in its own hardened building. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System

  5. Preoperational test report, raw water system

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-10-29

    This represents the preoperational test report for the Raw Water System, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system supplies makeup water to the W-030 recirculation evaporative cooling towers for tanks AY1O1, AY102, AZ1O1, AZ102. The Raw Water pipe riser and associated strainer and valving is located in the W-030 diesel generator building. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  6. Preoperational test report, recirculation ventilation systems

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-11-11

    This represents a preoperational test report for Recirculation Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides vapor space cooling of tanks AY1O1, AY102, AZ1O1, AZ102 and supports the ability to exhaust air from each tank. Each system consists of a valved piping loop, a fan, condenser, and moisture separator; equipment is located inside each respective tank farm in its own hardened building. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  7. Preoperational test report, primary ventilation condensate system

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-01-29

    Preoperational test report for Primary Ventilation Condensate System, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides a collection point for condensate generated by the W-030 primary vent offgas cooling system serving tanks AYIOI, AY102, AZIOI, AZI02. The system is located inside a shielded ventilation equipment cell and consists of a condensate seal pot, sampling features, a drain line to existing Catch Tank 241-AZ-151, and a cell sump jet pump. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  8. Preoperational test report, raw water system

    International Nuclear Information System (INIS)

    Clifton, F.T.

    1997-01-01

    This represents the preoperational test report for the Raw Water System, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system supplies makeup water to the W-030 recirculation evaporative cooling towers for tanks AY1O1, AY102, AZ1O1, AZ102. The Raw Water pipe riser and associated strainer and valving is located in the W-030 diesel generator building. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System

  9. Preoperative steroid in abdominal wall reconstruction

    DEFF Research Database (Denmark)

    Jensen, Kristian Kiim; Brøndum, Tina Lee; Belhage, Bo

    2016-01-01

    INTRODUCTION: Preoperative administration of high-dose glucocorticoid leads to improved recovery and decreased length of stay after abdominal surgery. Even so, studies on administration of glucocorticoids for patients undergoing abdominal wall reconstruction (AWR) for giant ventral hernia repair...... defect exceeding 10 cm will be randomised for intravenous administration of either 125 mg methylprednisolone or saline at the induction of anaesthesia. The primary endpoint is pain at rest on the first post-operative day. Patients will be followed until 30 days post-operatively, and secondary outcomes...

  10. Formulation and Evaluation of Microsphere Based Oro Dispersible Tablets of Itopride Hcl

    Directory of Open Access Journals (Sweden)

    S.S Agrawal

    2012-09-01

    Full Text Available Background The purpose of the present work is to mask the intensely bitter taste of Itopride HCl and to formulate an Oro dispersible tablet (ODT of the taste-masked drug by incorporation of microspheres in the tablets for use in specific populations viz. pediatrics, geriatrics and patients experiencing difficulty in swallowing.Methods:With this objective in mind, microspheres loaded with Itopride HCl were prepared by solvent evaporation method using acetone as solvent for pH-sensitive polymer, Eudragit EPO and light liquid paraffin as the encapsulating medium. The prepared microspheres were characterized with regard to yield, drug content, flow properties, particle size and size distribution, surface features, in vitro drug release and taste. The ODTs so prepared from these microspheres were evaluated for hardness, thickness, weight variation, friability, disintegration time, drug content, wetting time, water absorption ratio, moisture uptake, in vitro dispersion, in vitro disintegration, in vitro drug release and stability. Results:The average size of microspheres was found to be satisfactory in terms of the size and size distribution. Microspheres prepared were of a regular spherical shape. Comparison of the dissolution profiles of microspheres in different pH media showed that microspheres having drug: polymer ratio of 1:2 produced a retarding effect in simulated salivary fluid (pH 6.8 and were further used for formulation into ODTs after addition of suitable amounts of excipients such as superdisintegrant, diluent, sweetener and flavor of directly compressible grade. ConclusionsEffective taste-masking was achieved for Itopride HCl by way of preparation of microspheres and ODTs of acceptable characteristics.

  11. Simple Synthesis of Molybdenum Disulfide/Reduced Graphene Oxide Composite Hollow Microspheres as Supercapacitor Electrode Material.

    Science.gov (United States)

    Xiao, Wei; Zhou, Wenjie; Feng, Tong; Zhang, Yanhua; Liu, Hongdong; Tian, Liangliang

    2016-09-20

    MoS₂/RGO composite hollow microspheres were hydrothermally synthesized by using SiO₂/GO microspheres as a template, which were obtained via the sonication-assisted interfacial self-assembly of tiny GO sheets on positively charged SiO₂ microspheres. The structure, morphology, phase, and chemical composition of MoS₂/RGO hollow microspheres were systematically investigated by a series of techniques such as FE-SEM, TEM, XRD, TGA, BET, and Raman characterizations, meanwhile, their electrochemical properties were carefully evaluated by CV, GCD, and EIS measurements. It was found that MoS₂/RGO hollow microspheres possessed unique porous hollow architecture with high-level hierarchy and large specific surface area up to 63.7 m²·g -1 . When used as supercapacitor electrode material, MoS₂/RGO hollow microspheres delivered a maximum specific capacitance of 218.1 F·g -1 at the current density of 1 A·g -1 , which was much higher than that of contrastive bare MoS₂ microspheres developed in the present work and most of other reported MoS₂-based materials. The enhancement of supercapacitive behaviors of MoS₂/RGO hollow microspheres was likely due to the improved conductivity together with their distinct structure and morphology, which not only promoted the charge transport but also facilitated the electrolyte diffusion. Moreover, MoS₂/RGO hollow microsphere electrode displayed satisfactory long-term stability with 91.8% retention of the initial capacitance after 1000 charge/discharge cycles at the current density of 3 A·g -1 , showing excellent application potential.

  12. Simple Synthesis of Molybdenum Disulfide/Reduced Graphene Oxide Composite Hollow Microspheres as Supercapacitor Electrode Material

    Directory of Open Access Journals (Sweden)

    Wei Xiao

    2016-09-01

    Full Text Available MoS2/RGO composite hollow microspheres were hydrothermally synthesized by using SiO2/GO microspheres as a template, which were obtained via the sonication-assisted interfacial self-assembly of tiny GO sheets on positively charged SiO2 microspheres. The structure, morphology, phase, and chemical composition of MoS2/RGO hollow microspheres were systematically investigated by a series of techniques such as FE-SEM, TEM, XRD, TGA, BET, and Raman characterizations, meanwhile, their electrochemical properties were carefully evaluated by CV, GCD, and EIS measurements. It was found that MoS2/RGO hollow microspheres possessed unique porous hollow architecture with high-level hierarchy and large specific surface area up to 63.7 m2·g−1. When used as supercapacitor electrode material, MoS2/RGO hollow microspheres delivered a maximum specific capacitance of 218.1 F·g−1 at the current density of 1 A·g−1, which was much higher than that of contrastive bare MoS2 microspheres developed in the present work and most of other reported MoS2-based materials. The enhancement of supercapacitive behaviors of MoS2/RGO hollow microspheres was likely due to the improved conductivity together with their distinct structure and morphology, which not only promoted the charge transport but also facilitated the electrolyte diffusion. Moreover, MoS2/RGO hollow microsphere electrode displayed satisfactory long-term stability with 91.8% retention of the initial capacitance after 1000 charge/discharge cycles at the current density of 3 A·g−1, showing excellent application potential.

  13. Formulation and evaluation of microsphere based oro dispersible tablets of itopride hcl

    Directory of Open Access Journals (Sweden)

    Shah Sanjay

    2012-09-01

    Full Text Available Abstract Background The purpose of the present work is to mask the intensely bitter taste of Itopride HCl and to formulate an Oro dispersible tablet (ODT of the taste-masked drug by incorporation of microspheres in the tablets for use in specific populations viz. pediatrics, geriatrics and patients experiencing difficulty in swallowing. Methods With this objective in mind, microspheres loaded with Itopride HCl were prepared by solvent evaporation method using acetone as solvent for pH-sensitive polymer, Eudragit EPO and light liquid paraffin as the encapsulating medium. The prepared microspheres were characterized with regard to yield, drug content, flow properties, particle size and size distribution, surface features, in vitro drug release and taste. The ODTs so prepared from these microspheres were evaluated for hardness, thickness, weight variation, friability, disintegration time, drug content, wetting time, water absorption ratio, moisture uptake, in vitro dispersion, in vitro disintegration, in vitro drug release and stability. Results The average size of microspheres was found to be satisfactory in terms of the size and size distribution. Microspheres prepared were of a regular spherical shape. Comparison of the dissolution profiles of microspheres in different pH media showed that microspheres having drug: polymer ratio of 1:2 produced a retarding effect in simulated salivary fluid (pH 6.8 and were further used for formulation into ODTs after addition of suitable amounts of excipients such as superdisintegrant, diluent, sweetener and flavor of directly compressible grade. Conclusions Effective taste-masking was achieved for Itopride HCl by way of preparation of microspheres and ODTs of acceptable characteristics.

  14. Formulation and evaluation of microsphere based oro dispersible tablets of itopride hcl.

    Science.gov (United States)

    Shah, Sanjay; Madan, Sarika; Agrawal, Ss

    2012-09-03

    The purpose of the present work is to mask the intensely bitter taste of Itopride HCl and to formulate an Oro dispersible tablet (ODT) of the taste-masked drug by incorporation of microspheres in the tablets for use in specific populations viz. pediatrics, geriatrics and patients experiencing difficulty in swallowing. With this objective in mind, microspheres loaded with Itopride HCl were prepared by solvent evaporation method using acetone as solvent for pH-sensitive polymer, Eudragit EPO and light liquid paraffin as the encapsulating medium. The prepared microspheres were characterized with regard to yield, drug content, flow properties, particle size and size distribution, surface features, in vitro drug release and taste. The ODTs so prepared from these microspheres were evaluated for hardness, thickness, weight variation, friability, disintegration time, drug content, wetting time, water absorption ratio, moisture uptake, in vitro dispersion, in vitro disintegration, in vitro drug release and stability. The average size of microspheres was found to be satisfactory in terms of the size and size distribution. Microspheres prepared were of a regular spherical shape. Comparison of the dissolution profiles of microspheres in different pH media showed that microspheres having drug: polymer ratio of 1:2 produced a retarding effect in simulated salivary fluid (pH 6.8) and were further used for formulation into ODTs after addition of suitable amounts of excipients such as superdisintegrant, diluent, sweetener and flavor of directly compressible grade. Effective taste-masking was achieved for Itopride HCl by way of preparation of microspheres and ODTs of acceptable characteristics.

  15. Synthesis of plastic scintillation microspheres: Alpha/beta discrimination

    International Nuclear Information System (INIS)

    Santiago, L.M.; Bagán, H.; Tarancón, A.; Garcia, J.F.

    2014-01-01

    Plastic scintillation microspheres (PSm) have been developed as an alternative for liquid scintillation cocktails due to their ability to avoid the mixed waste, besides other strengths in which the possibility for alpha/beta discrimination is included. The aim of this work was to evaluate the capability of PSm containing two combinations of fluorescence solutes (PPO/POPOP and pT/Bis-MSB) and variable amounts of a second organic solvent (naphthalene) to enhance the alpha/beta discrimination. Two commercial detectors with different Pulse Shape Discrimination performances (Quantulus and Triathler) were used to evaluate the alpha/beta discrimination. An optimal discrimination of alpha/beta particles was reached, with very low misclassification values (2% for beta particles and 0.5% for alpha particles), when PSm containing PPO/POPOP and between 0.6 and 2.0 g of naphthalene were evaluated using Triathler and the appropriate programme for data processing. - Highlights: • Plastic scintillation microspheres for α/β discrimination have been synthesised. • The energy transfer process in PSm with different compositions has been investigated. • The α/β discrimination capabilities of two commercial detectors have been evaluated. • 2% and 0.5% of misclassifications for β and α radionuclides have been achieved respectively

  16. Synthesis, characterisation and biomedical applications of curcumin conjugated chitosan microspheres.

    Science.gov (United States)

    Saranya, T S; Rajan, V K; Biswas, Raja; Jayakumar, R; Sathianarayanan, S

    2018-04-15

    Curcumin is a diaryl heptanoid of curcuminoids class obtained from Curcuma longa. It possesses various biological activities like anti-inflammatory, hypoglycemic, antioxidant, wound-healing, and antimicrobial activities. Chitosan is a biocompatible, biodegradable and non-toxic natural polymer which enhances the adhesive property of the skin. Chemical conjugation will leads to sustained release action and to enhance the bioavailability. This study aims to synthesis and characterize biocompatible curcumin conjugated chitosan microspheres for bio-medical applications. The Schiff base reaction was carried out for the preparation of curcumin conjugated chitosan by microwave method and it was characterised using FTIR and NMR. Curcumin conjugated chitosan microspheres (CCCMs) were prepared by wet milling solvent evaporation method. SEM analysis showed these CCCMs were 2-5μm spherical particles. The antibacterial activities of the prepared CCCMs were studied against Staphylococcus aureus and Escherichia coli, the zone of inhibition was 28mm and 23mm respectively. Antioxidant activity of the prepared CCCMs was also studied by DPPH and H 2 O 2 method it showed IC 50 esteem value of 216μg/ml and 228μg/ml, and anti-inflammatory activity results showed that CCCMs having IC 50 value of 45μg/ml. The results conclude that the CCCMs having a good antibacterial, antioxidant and anti-inflammatory activities. This, the prepared CCCMs have potential application in preventing skin infections. Copyright © 2017. Published by Elsevier B.V.

  17. Properties of dry masonry mixtures based on hollow aluminosilicate microspheres

    Directory of Open Access Journals (Sweden)

    Semenov Vyacheslav

    2017-01-01

    Full Text Available At present, there is a steady increase in the volume of housing construction in the Russian Federation. The modern trends in the field of energy and resource saving determine the need of the use of efficient building materials that ensure the safety, comfort and minimum cost of housing construction. Among the materials, often used for erecting of fencing structures, it is possible to note effective small-piece elements (ceramic and light-weight concrete units, etc.. To ensure the solidity of such structures, it is necessary to use the masonry mortars whose properties correspond to those of the main wall material. The existing dry mixes for obtaining of such mortars are expensive and often do not meet the minimum physical-and-mechanical and exploitation requirements. The solution of this problem is the usage of the hollow ceramics (aluminosilicate microspheres as a filler for such mixes. The article presents the results of studies of the main physical-and-mechanical and exploitation characteristics of dry masonry mixes with hollow ceramics microspheres modified with various chemical additives. The effect of the compounding factors on the average density and strength of dry masonry mixes was studied. The compositions have been optimized by the methods of mathematical planning.

  18. Yttrium 90 microspheres for the treatment of hepatocellular carcinoma.

    Science.gov (United States)

    Memon, Khairuddin; Lewandowski, Robert J; Riaz, Ahsun; Salem, Riad

    2013-01-01

    Yttrium-90 microspheres are radioactive particles which are increasingly being employed for treating patients with unresectable hepatocellular carcinoma (HCC). The procedure is called radioembolization. It involves the injection of micron-sized embolic particles loaded with a radioisotope by use of transarterial techniques. Because of the sensitivity of liver parenchyma and relative insensitivity of tumor, external radiation has played a limited role in treating HCC. (90)Y administered via arterial route directs the highly concentrated radiation to the tumor while healthy liver parenchyma is relatively spared due to its preferential blood supply from portal venous blood. This technique has proven useful for the majority of patients with HCC as most of them present in advanced stage, beyond potentially curative options (resection/liver transplantation). (90)Y microspheres can be used in downstaging large tumors to bring within transplantable criteria, in patients with portal venous thrombosis due to tumor invasion and as palliative therapy. There are two available devices for (90)Y administration; TheraSphere® (glass based) and SIR-Spheres® (resin based). The procedure is performed on an outpatient basis. The incidence of complications is comparatively less and may include nausea, fatigue, abdominal pain, hepatic dysfunction, biliary injury, fibrosis, radiation pneumonitis, GI ulcers, and vascular injury; however, these can be avoided by meticulous pretreatment assessment, careful patient selection, and adequate dosimetry. This article explores the technical and clinical aspects of (90)Y radioembolization with keeping emphasis on patient selection, uses, and complications.

  19. Biocompatibility of Bletilla striata Microspheres as a Novel Embolic Agent

    Directory of Open Access Journals (Sweden)

    ShiHua Luo

    2015-01-01

    Full Text Available We have prepared Chinese traditional herb Bletilla striata into microspheres as a novel embolic agent for decades. The aim of this study was to evaluate the biocompatibility of Bletilla striata microspheres (BSMs. After a thermal test of BSMs in vitro, the cell biocompatibility of BSMs was investigated in mouse fibroblasts and human umbilical vein endothelial cells using the methyl tetrazolium (MTT assay. In addition, blood biocompatibility was evaluated. In vivo intramuscular implantation and renal artery embolization in rabbits with BSMs were used to examine the inflammatory response. The experimental rabbits did not develop any fever symptoms after injection of BSMs, and BSMs exhibited no cytotoxicity in cultured mouse fibroblasts and human umbilical vein endothelial cells. Additionally, BSMs exhibited high compatibility with red blood cells and no hemolysis activity. Intramuscular implantation with BSMs resulted in a gradually lessened mild inflammatory reaction that disappeared after eight weeks. The occlusion of small renal vessels was associated with a mild perivascular inflammatory reaction without significant renal and liver function damage. In conclusion, we believe that BSMs exhibit high biocompatibility and are a promising embolic agent.

  20. Large-area parallel near-field optical nanopatterning of functional materials using microsphere mask

    Energy Technology Data Exchange (ETDEWEB)

    Chen, G.X. [NUS Nanoscience and Nanotechnology Initiative, National University of Singapore, 2 Engineering Drive 3, Singapore 117576 (Singapore); Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117576 (Singapore); Hong, M.H. [NUS Nanoscience and Nanotechnology Initiative, National University of Singapore, 2 Engineering Drive 3, Singapore 117576 (Singapore); Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117576 (Singapore); Data Storage Institute, ASTAR, DSI Building, 5 Engineering Drive 1, Singapore 117608 (Singapore)], E-mail: Hong_Minghui@dsi.a-star.edu.sg; Lin, Y. [NUS Nanoscience and Nanotechnology Initiative, National University of Singapore, 2 Engineering Drive 3, Singapore 117576 (Singapore); Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117576 (Singapore); Wang, Z.B. [Data Storage Institute, ASTAR, DSI Building, 5 Engineering Drive 1, Singapore 117608 (Singapore); Ng, D.K.T. [Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117576 (Singapore); Data Storage Institute, ASTAR, DSI Building, 5 Engineering Drive 1, Singapore 117608 (Singapore); Xie, Q. [Data Storage Institute, ASTAR, DSI Building, 5 Engineering Drive 1, Singapore 117608 (Singapore); Tan, L.S. [NUS Nanoscience and Nanotechnology Initiative, National University of Singapore, 2 Engineering Drive 3, Singapore 117576 (Singapore); Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117576 (Singapore); Chong, T.C. [Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117576 (Singapore); Data Storage Institute, ASTAR, DSI Building, 5 Engineering Drive 1, Singapore 117608 (Singapore)

    2008-01-31

    Large-area parallel near-field optical nanopatterning on functional material surfaces was investigated with KrF excimer laser irradiation. A monolayer of silicon dioxide microspheres was self-assembled on the sample surfaces as the processing mask. Nanoholes and nanospots were obtained on silicon surfaces and thin silver films, respectively. The nanopatterning results were affected by the refractive indices of the surrounding media. Near-field optical enhancement beneath the microspheres is the physical origin of nanostructure formation. Theoretical calculation was performed to study the intensity of optical field distributions under the microspheres according to the light scattering model of a sphere on the substrate.

  1. Encapsulation of Liposomes within pH Responsive Microspheres for Oral Colonic Drug Delivery

    Directory of Open Access Journals (Sweden)

    M. J. Barea

    2012-01-01

    Full Text Available A novel liposome-in-microsphere (LIM formulation has been created comprising drug-loaded liposomes within pH responsive Eudragit S100 microspheres. The liposomes contained the model drug 5-ASA and were coated with chitosan in order to protect them during encapsulation within the microspheres and to improve site-specific release characteristics. In vitro drug release studies showed that LIMs prevented drug release within simulated stomach and small intestine conditions with subsequent drug release occurring in large intestine conditions. The formulation therefore has potential for oral colonic drug delivery.

  2. Preparation and properties of hollow glass microspheres for use in laser fusion experiments

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, J.H.; Grens, J.Z.; Poco, J.F.

    1983-11-01

    We review the preparation of high quality, hollow-glass microspheres for use in laser driven fusion experiments at LLNL. The primary focus of this paper is on the liquid-droplet method for making glass spheres, which has been in use at LLNL for over six years. We have combined the results from previous studies with our current results to present a detailed description of the preparation and the composition and physical properties of the glass microspheres. We also present a mathematical model that simulates the microsphere formation process. Examples are given of the application of the model to study the effects of various process parameters.

  3. Preparation and properties of hollow glass microspheres for use in laser fusion experiments

    International Nuclear Information System (INIS)

    Campbell, J.H.; Grens, J.Z.; Poco, J.F.

    1983-01-01

    We review the preparation of high quality, hollow-glass microspheres for use in laser driven fusion experiments at LLNL. The primary focus of this paper is on the liquid-droplet method for making glass spheres, which has been in use at LLNL for over six years. We have combined the results from previous studies with our current results to present a detailed description of the preparation and the composition and physical properties of the glass microspheres. We also present a mathematical model that simulates the microsphere formation process. Examples are given of the application of the model to study the effects of various process parameters

  4. A method and apparatus for the manufacture of glass microspheres adapted to contain a thermonuclear fuel

    International Nuclear Information System (INIS)

    Budrick, R.G.; Nolen, R.L. Jr.; Solomon, D.E.; King, F.T.

    1975-01-01

    The invention relates to the manufacture of glass microspheres. It refers to a method according to which a sintered glass-powder, whose particles are calibrated, is introduced into a blow-pipe adapted to project said glass-powder particles into a heated flue, said sintered glass-powder containing a pore-forming agent adapted to expand the glass particles into microspheres which are collected in a chamber situated abode said flue. The method can be applied to the manufacture of microspheres adapted to contain a thermonuclear fuel [fr

  5. Formation of microspheres under the action of femtosecond laser radiation on titanium samples in hydrocarbons

    Science.gov (United States)

    Kochuev, D. A.; Khorkov, K. S.; Ivashchenko, A. V.; Prokoshev, V. G.; Arakelian, S. M.

    2018-01-01

    This work describes the original method of laser synthesis of microspheres which contain titanium carbide. The formation of microspheres is carried out by the action of femtosecond laser radiation on the surface of titanium in the reaction medium - the ultimate hydrocarbon. The resulting microspheres have a high surface smoothness, a narrow particle size distribution, an average size of 1-3 μm. They can be used in applications of additive engineering, powder metallurgy as the main raw material, or as an alloying additive.

  6. Sustained release donepezil loaded PLGA microspheres for injection: Preparation, in vitro and in vivo study

    DEFF Research Database (Denmark)

    Guo, Wenjia; Quan, Peng; Fang, Liang

    2015-01-01

    -solvent evaporation method. The optimized formulation which avoided the crushing of microspheres during the preparation process was characterized in terms of particle size, morphology, drug loading and EE, physical state of DP in the matrix and in vitro and in vivo release behavior. DP microspheres were prepared...... release mechanism. After single-dose administration of DP microspheres via subcutaneous injection in rats, the plasma concentration of DP reached peak concentration at 0.50 d, and then declined gradually, but was still detectable at 15 d. A good correlation between in vitro and in vivo data was obtained...

  7. Minimizing resputtering of Pt-coated microspheres in a batch magnetron sputtering process

    International Nuclear Information System (INIS)

    Plake, A.L.

    1981-01-01

    Preventing DT loss from glass microspheres being smoothly coated with PT is needed during fabrication of laser fusion targets. Evidence indicates that the increase of substrate temperature due to resputtering will cause DT loss. Resputtering will prevent a smooth and uniform coating on these glass microspheres (140 μm in diameter). This paper reviews the method that was developed to find a set of coating conditions to minimize the DT loss, and still be able to produce thick smooth Pt coated glass microspheres

  8. Preparation and characterization of monodisperse large-porous silica microspheres as the matrix for protein separation.

    Science.gov (United States)

    Xia, Hongjun; Wan, Guangping; Zhao, Junlong; Liu, Jiawei; Bai, Quan

    2016-11-04

    High performance liquid chromatography (HPLC) is a kind of efficient separation technology and has been used widely in many fields. Micro-sized porous silica microspheres as the most popular matrix have been used for fast separation and analysis in HPLC. In this paper, the monodisperse large-porous silica microspheres with controllable size and structure were successfully synthesized with polymer microspheres as the templates and characterized. First, the poly(glycidyl methacrylate-co-ethyleneglycol dimethacrylate) microspheres (P GMA-EDMA ) were functionalized with tetraethylenepentamine (TEPA) to generate amino groups which act as a catalyst in hydrolysis of tetraethyl orthosilicate (TEOS) to form Si-containing low molecular weight species. Then the low molecular weight species diffused into the functionalized P GMA-EDMA microspheres by induction force of the amino groups to form polymer/silica hybrid microspheres. Finally, the organic polymer templates were removed by calcination, and the large-porous silica microspheres were obtained. The compositions, morphology, size distribution, specific surface area and pore size distribution of the porous silica microspheres were characterized by infrared analyzer, scanning-electron microscopy, dynamic laser scattering, the mercury intrusion method and thermal gravimetric analysis, respectively. The results show that the agglomeration of the hybrid microspheres can be overcome when the templates were functionalized with TEPA as amination reagent, and the yield of 95.7% of the monodisperse large-porous silica microspheres can be achieved with high concentration of polymer templates. The resulting large-porous silica microspheres were modified with octadecyltrichlorosilane (ODS) and the chromatographic evaluation was performed by separating the proteins and the digest of BSA. The baseline separation of seven kinds of protein standards was achieved, and the column delivered a better performance when separating BSA digests

  9. Preoperative chemoradiation therapy for advanced rectal cancer

    International Nuclear Information System (INIS)

    Tsujinaka, Toshimasa; Murotani, Masahiro; Iihara, Keisuke

    1997-01-01

    Preoperative concurrent chemoradiation therapy with 5-fluorouracil and cisplatin was applied for advanced rectal cancer. Eligible criteria were as follows: no previous treatment, more than hemicircular occupation, T 3 or more, invasion to adjacent organs or lymph node metastasis on CT scan, tumor fixation by digital examination. Eleven patients were enrolled with this regimen consisting of 5-FU; 500 mg/day x 5/w x 4, CDDP; 10 mg/day x 5/w x 4 and radiation; 2 Gy x 5/w x 4. As a toxicity, grade 2 leukopenia in 2 cases, grade 2 GI symptoms in one case and radiation dermatitis was observed in 8 cases. As a local response, there were PR in 10 cases and NC in 1 case. Surgical resection was performed on 8 patients. Histological responses in the resected specimens were grade 2, 5 cases; grade 1b, 1 case; and grade 1a, 2 cases. Operative radicalities were grade A, 3 cases; grade B, 3 cases; and grade C, 2 cases. Preoperative chemoradiation is one of the effective options in multimodal treatment for advanced rectal cancer. (author)

  10. Religiousness and preoperative anxiety: a correlational study

    Directory of Open Access Journals (Sweden)

    Karimollahi Mansoureh

    2007-06-01

    Full Text Available Abstract Background Major life changes are among factors that cause anxiety, and one of these changes is surgery. Emotional reactions to surgery have specific effects on the intensity and velocity as well as the process of physical disease. In addition, they can cause delay in patients recovery. This study is aimed at determining the relationship between religious beliefs and preoperative anxiety. Methods This survey is a correlational study to assess the relationship between religious beliefs and preoperative anxiety of patients undergoing abdominal, orthopaedic, and gynaecologic surgery in educational hospitals. We used the convenience sampling method. The data collection instruments included a questionnaire containing the Spielberger State-Trait Anxiety Inventory (STAI, and another questionnaire formulated by the researcher with queries on religious beliefs and demographic characteristics as well as disease-related information. Analysis of the data was carried out with SPSS software using descriptive and inferential statistics. Results were arranged in three tables. Results The findings showed that almost all the subjects had high level of religiosity and moderate level of anxiety. In addition, there was an inverse relationship between religiosity and intensity of anxiety, though this was not statistically significant. Conclusion The results of this study can be used as evidence for presenting religious counselling and spiritual interventions for individuals undergoing stress. Finally, based on the results of this study, the researcher suggested some recommendations for applying results and conducting further research.

  11. Preoperative chemoradiotherapy for locally advanced gastric cancer

    International Nuclear Information System (INIS)

    Pepek, Joseph M; Chino, Junzo P; Willett, Christopher G; Palta, Manisha; Blazer III, Dan G; Tyler, Douglas S; Uronis, Hope E; Czito, Brian G

    2013-01-01

    To examine toxicity and outcomes for patients treated with preoperative chemoradiotherapy (CRT) for gastric cancer. Patients with gastroesophageal (GE) junction (Siewert type II and III) or gastric adenocarcinoma who underwent neoadjuvant CRT followed by planned surgical resection at Duke University between 1987 and 2009 were reviewed. Overall survival (OS), local control (LC) and disease-free survival (DFS) were estimated using the Kaplan-Meier method. Toxicity was graded according to the Common Toxicity Criteria for Adverse Events version 4.0. Forty-eight patients were included. Most (73%) had proximal (GE junction, cardia and fundus) tumors. Median radiation therapy dose was 45 Gy. All patients received concurrent chemotherapy. Thirty-six patients (75%) underwent surgery. Pathologic complete response and R0 resection rates were 19% and 86%, respectively. Thirty-day surgical mortality was 6%. At 42 months median follow-up, 3-year actuarial OS was 40%. For patients undergoing surgery, 3-year OS, LC and DFS were 50%, 73% and 41%, respectively. Preoperative CRT for gastric cancer is well tolerated with acceptable rates of perioperative morbidity and mortality. In this patient cohort with primarily advanced disease, OS, LC and DFS rates in resected patients are comparable to similarly staged, adjuvantly treated patients in randomized trials. Further study comparing neoadjuvant CRT to standard treatment approaches for gastric cancer is indicated

  12. Preoperative chemoradiotherapy for locally advanced gastric cancer

    Directory of Open Access Journals (Sweden)

    Pepek Joseph M

    2013-01-01

    Full Text Available Abstract Background To examine toxicity and outcomes for patients treated with preoperative chemoradiotherapy (CRT for gastric cancer. Methods Patients with gastroesophageal (GE junction (Siewert type II and III or gastric adenocarcinoma who underwent neoadjuvant CRT followed by planned surgical resection at Duke University between 1987 and 2009 were reviewed. Overall survival (OS, local control (LC and disease-free survival (DFS were estimated using the Kaplan-Meier method. Toxicity was graded according to the Common Toxicity Criteria for Adverse Events version 4.0. Results Forty-eight patients were included. Most (73% had proximal (GE junction, cardia and fundus tumors. Median radiation therapy dose was 45 Gy. All patients received concurrent chemotherapy. Thirty-six patients (75% underwent surgery. Pathologic complete response and R0 resection rates were 19% and 86%, respectively. Thirty-day surgical mortality was 6%. At 42 months median follow-up, 3-year actuarial OS was 40%. For patients undergoing surgery, 3-year OS, LC and DFS were 50%, 73% and 41%, respectively. Conclusions Preoperative CRT for gastric cancer is well tolerated with acceptable rates of perioperative morbidity and mortality. In this patient cohort with primarily advanced disease, OS, LC and DFS rates in resected patients are comparable to similarly staged, adjuvantly treated patients in randomized trials. Further study comparing neoadjuvant CRT to standard treatment approaches for gastric cancer is indicated.

  13. Religiousness and preoperative anxiety: a correlational study.

    Science.gov (United States)

    Kalkhoran, Masoomeh Aghamohammadi; Karimollahi, Mansoureh

    2007-06-29

    Major life changes are among factors that cause anxiety, and one of these changes is surgery. Emotional reactions to surgery have specific effects on the intensity and velocity as well as the process of physical disease. In addition, they can cause delay in patients recovery. This study is aimed at determining the relationship between religious beliefs and preoperative anxiety. This survey is a correlational study to assess the relationship between religious beliefs and preoperative anxiety of patients undergoing abdominal, orthopaedic, and gynaecologic surgery in educational hospitals. We used the convenience sampling method. The data collection instruments included a questionnaire containing the Spielberger State-Trait Anxiety Inventory (STAI), and another questionnaire formulated by the researcher with queries on religious beliefs and demographic characteristics as well as disease-related information. Analysis of the data was carried out with SPSS software using descriptive and inferential statistics. Results were arranged in three tables. The findings showed that almost all the subjects had high level of religiosity and moderate level of anxiety. In addition, there was an inverse relationship between religiosity and intensity of anxiety, though this was not statistically significant. The results of this study can be used as evidence for presenting religious counselling and spiritual interventions for individuals undergoing stress. Finally, based on the results of this study, the researcher suggested some recommendations for applying results and conducting further research.

  14. The preoperative imaging evaluation for cochlear implantation

    International Nuclear Information System (INIS)

    Liu Zhonglin; Wang Zhenchang; Fu Lin; Li Yong; Xian Junfang; Yang Bentao; Lan Baosen; Li Yongxin; Zheng Jun; Song Yan; Liu Bo; Chen Xueqing; He Haili

    2006-01-01

    Objective: To analyze CT and MRI findings of temporal bone and to evaluate preoperative diagnostic value for cochlear implantation. Methods: One hundred and sixty candidates for cochlear implantation were examined with axial CT scan, 64 of them also with coronal CT scan, and 119 patients with MRI. Results: All of 320 ears were well-aerated, and 206 ears had mastoid cavities extended posteriorly to the sigmoid sinus. The length from posterior-lateral tympanic wall to the outer cortex was (2.34±0.42) mm (left side) and (2.25±0.40) mm (right side) (U=1.887, P 1 and T 2 signal on MRI. The congenital malformations of inner ear occurred in 67 ears, including complete dysplasia in 1 ear, cochlear hypodysplasia in 6 ears, Mondini deformation in 5 ears, enlarged vestibular aqueduct in 40 ears, dysplastic semicircular canal and the vestibulae in 10 ears, and narrowing of internal auditory canal in 5 ears. Conclusion: Preoperative imaging examinations can provide critical information to ensure successful cochlear' implantation. (authors)

  15. A critical inventory of preoperative skull replicas.

    Science.gov (United States)

    Fasel, J H D; Beinemann, J; Schaller, K; Gailloud, P

    2013-09-01

    Physical replicas of organs are used increasingly for preoperative planning. The quality of these models is generally accepted by surgeons. In view of the strong trend towards minimally invasive and personalised surgery, however, the aim of this investigation was to assess qualitatively the accuracy of such replicas, using skull models as an example. Skull imaging was acquired for three cadavers by computed tomography using clinical routine parameters. After digital three-dimensional (3D) reconstruction, physical replicas were produced by 3D printing. The facsimilia were analysed systematically and compared with the best gold standard possible: the macerated skull itself. The skull models were far from anatomically accurate. Non-conforming rendering was observed in particular for foramina, sutures, notches, fissures, grooves, channels, tuberosities, thin-walled structures, sharp peaks and crests, and teeth. Surgeons should be aware that preoperative models may not yet render the exact anatomy of the patient under consideration and are advised to continue relying, in specific conditions, on their own analysis of the native computed tomography or magnetic resonance imaging.

  16. Formulation, evaluation and 3(2) full factorial design-based optimization of ondansetron hydrochloride incorporated taste masked microspheres.

    Science.gov (United States)

    Kharb, Vandana; Saharan, Vikas Anand; Dev, Kapil; Jadhav, Hemant; Purohit, Suresh

    2014-11-01

    Masking the bitter taste of Ondansetron hydrochloride (ONS) may improve palatability, acceptance and compliance of ONS products. ONS-loaded, taste-masked microspheres were prepared with a polycationic pH-sensitive polymer and 3(2) full factorial design (FFD) was applied to optimize microsphere batches. Solvent evaporation, in acetone--methanol/liquid paraffin system, was used to prepare taste-masked ONS microspheres. The effect of varying drug/polymer (D/P) ratios on microspheres characteristics were studied by 3(2) FFD. Desirability function was used to search the optimum formulation. Microspheres were evaluated by FTIR, XRD and DSC to examine interaction and effect of microencapsulation process. In vitro taste assessment approach based on bitterness threshold and drug release was used to assess bitterness scores. Prepared ONS microspheres were spherical and surface was wrinkled. ONS was molecularly dispersed in microspheres without any incompatibility with EE100. In hydrochloric acid buffer pH 1.2, ONS released completely from microsphere in just 10 min. Contrary to this, ONS release at initial 5 min from taste-masked microspheres was less than the bitterness threshold. Full factorial design and in vitro taste assessment approach, coupled together, was successfully applied to develop and optimize batches of ONS incorporated taste-masked microspheres.

  17. Effect of WOW process parameters on morphology and burst release of FITC-dextran loaded PLGA microspheres.

    Science.gov (United States)

    Mao, Shirui; Xu, Jing; Cai, Cuifang; Germershaus, Oliver; Schaper, Andreas; Kissel, Thomas

    2007-04-04

    Using fluorescein isothiocyanate labeled dextran (FITC-dextran 40, FD40) as a hydrophilic model compound, microspheres were prepared by a WOW double emulsion technique. Influence of process parameters on microsphere morphology and burst release of FD40 from PLGA microspheres was studied. Internal morphology of microspheres was investigated by stereological method via cryo-cutting technique and scanning electron microscopy (SEM). Drug distribution in microspheres was observed with confocal laser scanning microscopy (CLSM). Polymer nature (RG503 and RG503H) had significant influence on the micro-morphology of microspheres. Increase in continuous water phase volume (W2) led to increased surface porosity but decreased internal porosity. By increasing PVA concentration in the continuous phase from 0.1 to 1%, particle size changed marginally but burst release decreased from 12.2 to 5.9%. Internal porosity of microspheres decreased considerably with increasing polymer concentration. Increase in homogenization speed during the primary emulsion preparation led to decreased internal porosity. Burst release decreased with increasing drug loading but increased with drug molecular weight. Drug distribution in microspheres depended on preparation method. The porosity of microspheres decreased with time in the diffusion stage, but internal morphology had no influence on the release behavior in the bioerosion stage. In summary, surface porosity and internal morphology play a significant role in the release of hydrophilic macromolecules from biodegradable microspheres in the initial release phase characterized by pore diffusion.

  18. Particle size modeling and morphology study of chitosan/gelatin/nanohydroxyapatite nanocomposite microspheres for bone tissue engineering.

    Science.gov (United States)

    Bagheri-Khoulenjani, Shadab; Mirzadeh, Hamid; Etrati-Khosroshahi, Mohammad; Shokrgozar, Mohammad Ali

    2013-06-01

    In this study, nanocomposite microspheres based on chitosan/gelatin/nanohydroxyapatite were fabricated, and effects of the nanohydroxyapatite/biopolymer (chitosan/gelatin) weight ratio (nHA/P), stirring rate, chitosan concentration and biopolymer concentration on the particle size, and morphology of nanocomposite microspheres were investigated. Particle size of microspheres was modeled by design of experiments using the surface response method. Particle size, morphology of microspheres, and distribution of nanoparticles within the composite microspheres were evaluated using an optical microscope, scanning electron microscopy (SEM) and transmission electron microscopy (TEM), respectively. X-ray diffraction and Fourier transform infrared spectroscopy were applied to study the physical and chemical characteristics of microspheres. Results showed that by modulating the nHA/P ratio, chitosan concentration, polymer concentration, and stirring rate, it is possible to fabricate microspheres in wide rages of particle size (5-150 μm). Analysis of variance confirmed that the modified quadratic model can be used to predict the particle size of nanocomposite microspheres within the design space. SEM studies showed that microspheres with different compositions had totally different morphologies from dense morphologies to porous ones. TEM images demonstrated that nanoparticles were distributed uniformly within the polymeric matrix. MTT assay and cell culture studies showed that microspheres with different compositions possessed good biocompatibility. © 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2013. Copyright © 2012 Wiley Periodicals, Inc.

  19. Development and optimization of enteric coated mucoadhesive microspheres of duloxetine hydrochloride using 3(2) full factorial design.

    Science.gov (United States)

    Setia, Anupama; Kansal, Sahil; Goyal, Naveen

    2013-07-01

    Microspheres constitute an important part of oral drug delivery system by virtue of their small size and efficient carrier capacity. However, the success of these microspheres is limited due to their short residence time at the site of absorption. The objective of the present study was to formulate and systematically evaluate in vitro performance of enteric coated mucoadhesive microspheres of duloxetine hydrochloride (DLX), an acid labile drug. DLX microspheres were prepared by simple emulsification phase separation technique using chitosan as carrier and glutaraldehyde as a cross-linking agent. Microspheres prepared were coated with eudragit L-100 using an oil-in-oil solvent evaporation method. Eudragit L-100was used as enteric coating polymer with the aim to release the drug in small intestine The microspheres prepared were characterized by particle size, entrapment efficiency, swelling index (SI), mucoadhesion time, in vitro drug release and surface morphology. A 3(2) full factorial design was employed to study the effect of independent variables polymer-to-drug ratio (X1) and stirring speed (X2) on dependent variables, particle size, entrapment efficiency, SI, in vitro mucoadhesion and drug release up to 24 h (t24). Microspheres formed were discrete, spherical and free flowing. The microspheres exhibited good mucoadhesive property and also showed high percentage entrapment efficiency. The microspheres were able to sustain the drug release up to 24 h. Thus, the prepared enteric coated mucoadhesive microspheres may prove to be a potential controlled release formulation of DLX for oral administration.

  20. Preoperative Quality of Life in Patients with Gastric Cancer

    OpenAIRE

    Suk, Hyoam; Kwon, Oh Kyung; Yu, Wansik

    2015-01-01

    Purpose We evaluated the socio-personal and clinical factors that can affect preoperative quality of life to determine how to improve preoperative quality of life in patients with gastric cancer. Materials and Methods The preoperative quality of life data of 200 patients (68 females and 132 males; mean age 58.9?12.6 years) with gastric cancer were analyzed according to socio-personal and clinical factors. The Korean versions of the European Organization for Research and Treatment of Cancer (E...

  1. The preoperative evaluation prevent the postoperative complications of thyroidectomy

    Directory of Open Access Journals (Sweden)

    Chien-Feng Huang

    2015-03-01

    Conclusions: The success of thyroid surgery depends on careful preoperative planning, including a preoperative neck ultrasound to determine the proximity of the nodule to the recurrent laryngeal nerve course, and the consideration of the type of anesthesia, adjuvant devices for intra-op monitoring of the RLN, and surgical modalities. Our results suggest that preoperative evaluation implementations are positively associated with strategy of surgery and postoperative hypocalcemia prevention.

  2. Preoperative stoma site marking in the general surgery population.

    Science.gov (United States)

    Zimnicki, Katherine M

    2013-01-01

    Preoperative teaching and stoma site marking are supported by research and professional organizations as interventions that can reduce the incidence of problematic stomas and improve patient outcomes. This study investigated the translation of this research into practice in the acute care surgery population. A retrospective chart review using convenience sampling was conducted at a large urban hospital in the Midwestern United States. Thirty patients underwent a surgical procedure that resulted in the creation of a fecal ostomy over a 5-month period. Descriptive statistical analysis examined the reason for surgery, preoperative length of stay (LOS), the percentage of patients who received preoperative teaching and stoma marking and the relationship between preoperative LOS and the use of preoperative teaching and stoma marking. Twenty-one of 30 patients were admitted to hospital 24 hours or more before surgery. No participants were admitted urgently. Three (14%) of those admitted for more than 24 hours received preoperative marking or teaching. There was no significant relationship between preoperative LOS and preoperative teaching and stoma marking. The opportunity exists to promote successful adaptation in this surgical population through the implementation of the evidence-based interventions of preoperative teaching and stoma marking. Additional study is needed to determine barriers to their use as well as to develop effective implementation strategies.

  3. Pre-operative pain and sensory function in groin hernia

    DEFF Research Database (Denmark)

    Aasvang, Eske K; Hansen, Jeanette B; Kehlet, Henrik

    2009-01-01

    BACKGROUND: Although persistent postherniotomy occurs in 5-10% of patients, pathogenic mechanisms remain debatable. Since pre-operative pain has been demonstrated to be a risk factor for persistent postherniotomy pain, pre-operative alterations in nociceptive function may be a potential pathogenic...... mechanism. AIMS: To investigate the correlation between pre-operative pain intensity and sensory functions in the groin hernia area. METHODS: Patients with unilateral groin hernia were examined preoperatively by quantitative sensory testing (thermal, mechanical, and pressure [detection and pain thresholds...... (7%), all whom experienced no pain or pain less than weekly. Only cool detection thresholds were significantly lower between the hernia vs. contralateral side (poperative groin hernia...

  4. Fabrication of Cerium Oxide and Uranium Oxide Microspheres for Space Nuclear Power Applications

    Energy Technology Data Exchange (ETDEWEB)

    Jeffrey A. Katalenich; Michael R. Hartman; Robert C. O' Brien

    2013-02-01

    Cerium oxide and uranium oxide microspheres are being produced via an internal gelation sol-gel method to investigate alternative fabrication routes for space nuclear fuels. Depleted uranium and non-radioactive cerium are being utilized as surrogates for plutonium-238 (Pu-238) used in radioisotope thermoelectric generators and for enriched uranium required by nuclear thermal rockets. While current methods used to produce Pu-238 fuels at Los Alamos National Laboratory (LANL) involve the generation of fine powders that pose a respiratory hazard and have a propensity to contaminate glove boxes, the sol-gel route allows for the generation of oxide microsphere fuels through an aqueous route. The sol-gel method does not generate fine powders and may require fewer processing steps than the LANL method with less operator handling. High-quality cerium dioxide microspheres have been fabricated in the desired size range and equipment is being prepared to establish a uranium dioxide microsphere production capability.

  5. Synthesis and electrochemical properties of {alpha}-MnO{sub 2} microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Wang Hongen [College of Chemistry and Chemical Engineering, Central South University, Changsha 410083 (China); Zhengzhou Research Institute of CHALCO, Zhengzhou Research Institute of Light Metals, Zhengzhou 450041 (China); Qian Dong [College of Chemistry and Chemical Engineering, Central South University, Changsha 410083 (China)], E-mail: qiandong6@yahoo.com.cn

    2008-06-15

    We report the synthesis of {alpha}-MnO{sub 2} microspheres by a low-temperature hydrothermal method involving no templates or catalysts. The products were characterized by powder X-ray diffraction (XRD), scanning electron microscopy (SEM), Energy-dispersive X-ray spectrum (EDX), transmission electron microscopy (TEM), Fourier transform infrared spectrum (FT-IR), and Brunauer-Emmett-Teller (BET). The results show that the as-synthesized products are mainly composed of large quantities of {alpha}-MnO{sub 2} microspheres having a sea-urchin shape and a few microspheres constructed of small nanorods. Electrochemical characterization indicates that the resulting {alpha}-MnO{sub 2} microspheres display promising discharge properties than the commercial electrolytic manganese dioxides (EMD) when used as cathodes in alkaline Zn-MnO{sub 2} batteries.

  6. In-vitro studies of enteric coated diclofenac sodium-carboxymethylcellulose microspheres.

    Science.gov (United States)

    Arica, B; Arica, M Y; Kaş, H S; Hincal, A A; Hasirci, V

    1996-01-01

    MIcrospheres containing diclofenac sodium (DS) were prepared using carboxymethylcellulose (CMC) as the main support material (1.0, 2.0, 3.0% (w/v)) and aluminum chloride as the crosslinker. Drug to polymer ratios of 1:1, 1:2 and 1:4 were used to obtain a range of microspheres. The microspheres were then coated with an enteric coating material, Eudragit S-100, efficiency, % yield value, particle sizes an in-vitro dissolution behaviour were investigated. The surface of the enteric coated microspheres seemed to be all covered with Eudragit S-100 from scanning electron microscopy observation. It was also observed that increasing the CMC concentration led to an increase in the encapsulation efficiency, % yield value and particle size and decreased the release rate. Eudragit S-100 coating did not significantly alter the size but the release rate was significantly lower even when the lower concentration solution was used.

  7. Sustained-release microsphere formulation containing an agrochemical by polyurethane polymerization during an agitation granulation process.

    Science.gov (United States)

    Terada, Takatoshi; Tagami, Manabu; Ohtsubo, Toshiro; Iwao, Yasunori; Noguchi, Shuji; Itai, Shigeru

    2016-07-25

    In this report, a new solventless microencapsulation method by synthesizing polyurethane (PU) from polyol and isocyanate during an agglomeration process in a high-speed mixing apparatus was developed. Clothianidin (CTD), which is a neonicotinoid insecticide and highly effective against a wide variety of insect pests, was used as the model compound. The microencapsulated samples covered with PU (CTD microspheres) had a median diameter of <75μm and sustained-release properties. The CTD microspheres were analyzed by synchrotron X-ray computed tomography measurements. Multiple cores of CTD and other solid excipient were dispersed in PU. Although voids appeared in the CTD microspheres after CTD release, the spherical shape of the microspheres remained stable and no change in its framework was observed. The experimental release data were highly consistent with the Baker-Lonsdale model derived from drug release of spherical monolithic dispersions and consistent with the computed tomography measurements. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Copper adsorption on magnetite-loaded chitosan microspheres: A kinetic and equilibrium study

    Energy Technology Data Exchange (ETDEWEB)

    Podzus, P.E., E-mail: ppodzus@gmail.com [Grupo de Aplicaciones de Materiales Biocompatibles, Departamento de Quimica, Facultad de Ingenieria, Universidad de Buenos Aires, Paseo Colon 850, C1063ACV Buenos Aires (Argentina); Debandi, M.V. [Grupo de Aplicaciones de Materiales Biocompatibles, Departamento de Quimica, Facultad de Ingenieria, Universidad de Buenos Aires, Paseo Colon 850, C1063ACV Buenos Aires (Argentina); Daraio, M.E., E-mail: medit@fi.uba.ar [Grupo de Aplicaciones de Materiales Biocompatibles, Departamento de Quimica, Facultad de Ingenieria, Universidad de Buenos Aires, Paseo Colon 850, C1063ACV Buenos Aires (Argentina)

    2012-08-15

    A composite of Fe{sub 3}O{sub 4} nanoparticles and the biopolymer chitosan, chemically crosslinked, was prepared as microspheres and used to adsorb copper ions, which were chosen as a model of contaminant metal in water. The adsorption of copper on the magnetic microspheres was studied in a batch process, with different aqueous solutions of Cu (II) at concentrations ranging from 40 to 1100 ppm. Kinetic and equilibrium aspects of the adsorption process were studied. The time-dependent Cu (II) adsorption data were well described by a pseudo-second-order kinetic model. It was found that the equilibrium data follow the Langmuir isotherm, with a maximum adsorption capacity of around 500 mg Cu/g chitosan. The used microspheres were removed and after desorption the material was able to be reused as an adsorbent. The prepared microspheres proved efficient in the removal of copper ions through an adsorption process whose kinetic and equilibrium characteristics were analyzed.

  9. Olive oil DNA fingerprinting by multiplex SNP genotyping on fluorescent microspheres.

    Science.gov (United States)

    Kalogianni, Despina P; Bazakos, Christos; Boutsika, Lemonia M; Targem, Mehdi Ben; Christopoulos, Theodore K; Kalaitzis, Panagiotis; Ioannou, Penelope C

    2015-04-01

    Olive oil cultivar verification is of primary importance for the competitiveness of the product and the protection of consumers and producers from fraudulence. Single-nucleotide polymorphisms (SNPs) have emerged as excellent DNA markers for authenticity testing. This paper reports the first multiplex SNP genotyping assay for olive oil cultivar identification that is performed on a suspension of fluorescence-encoded microspheres. Up to 100 sets of microspheres, with unique "fluorescence signatures", are available. Allele discrimination was accomplished by primer extension reaction. The reaction products were captured via hybridization on the microspheres and analyzed, within seconds, by a flow cytometer. The "fluorescence signature" of each microsphere is assigned to a specific allele, whereas the signal from a reporter fluorophore denotes the presence of the allele. As a model, a panel of three SNPs was chosen that enabled identification of five common Greek olive cultivars (Adramytini, Chondrolia Chalkidikis, Kalamon, Koroneiki, and Valanolia).

  10. Effect of crosslinking agents on chitosan microspheres in controlled release of diclofenac sodium

    Directory of Open Access Journals (Sweden)

    Vanessa L. Gonçalves

    2005-03-01

    Full Text Available In this work chitosan microspheres were prepared by the simple coacervation method and crosslinked using epichlorhydrin or glutaraldehyde for the controlled release of diclofenac sodium. The effects of the crosslinking agents on chitosan microspheres over a 12-hour period were assessed with regard to swelling, hydrolysis, porosity, crosslinking, impregnation of diclofenac sodium (DS, and consequently to the release of DS in buffer solutions, simulating the gastrointestinal tract. The degree of swelling varied with the pH for glutaraldehyde chitosan microspheres (GCM and epichlorhydrin chitosan microspheres (ECM. Partial acid and basic hydrolysis affected the swelling behavior of the GCM matrix. Release kinetics of diclofenac sodium from these matrices were investigated at pH 1.2, 6.8 and 9.0, simulating the gastrointestinal tract conditions. The results indicated that the release mechanism deviated slightly from Fickian transport.

  11. Copper adsorption on magnetite-loaded chitosan microspheres: A kinetic and equilibrium study

    International Nuclear Information System (INIS)

    Podzus, P.E.; Debandi, M.V.; Daraio, M.E.

    2012-01-01

    A composite of Fe 3 O 4 nanoparticles and the biopolymer chitosan, chemically crosslinked, was prepared as microspheres and used to adsorb copper ions, which were chosen as a model of contaminant metal in water. The adsorption of copper on the magnetic microspheres was studied in a batch process, with different aqueous solutions of Cu (II) at concentrations ranging from 40 to 1100 ppm. Kinetic and equilibrium aspects of the adsorption process were studied. The time-dependent Cu (II) adsorption data were well described by a pseudo-second-order kinetic model. It was found that the equilibrium data follow the Langmuir isotherm, with a maximum adsorption capacity of around 500 mg Cu/g chitosan. The used microspheres were removed and after desorption the material was able to be reused as an adsorbent. The prepared microspheres proved efficient in the removal of copper ions through an adsorption process whose kinetic and equilibrium characteristics were analyzed.

  12. A novel approach to preparing magnetic protein microspheres with core-shell structure

    Science.gov (United States)

    Jiang, Wei; Sun, Zhendong; Li, Fengsheng; Chen, Kai; Liu, Tianyu; Liu, Jialing; Zhou, Tianle; Guo, Rui

    2011-03-01

    Magnetic protein microspheres with core-shell structure were prepared through a novel approach based on the sonochemical method and the emulsion solvent evaporation method. The microspheres are composed of the oleic acid and undecylenic acid modified Fe 3O 4 cores and coated with globular bovine serum albumin (BSA). Under an optimized condition, up to 57.8 wt% of approximately 10 nm superparamagnetic Fe 3O 4 nanoparticles could be uniformly encapsulated into the BSA microspheres with the diameter of approximately 160 nm and the high saturation magnetization of 38.5 emu/g, besides of the abundant functional groups. The possible formation mechanism of magnetic microspheres was discussed in detail.

  13. Versatile microsphere attachment of GFP-labeled motors and other tagged proteins with preserved functionality

    Directory of Open Access Journals (Sweden)

    Michael Bugiel

    2015-11-01

    Full Text Available Microspheres are often used as handles for protein purification or force spectroscopy. For example, optical tweezers apply forces on trapped particles to which motor proteins are attached. However, even though many attachment strategies exist, procedures are often limited to a particular biomolecule and prone to non-specific protein or surface attachment. Such interactions may lead to loss of protein functionality or microsphere clustering. Here, we describe a versatile coupling procedure for GFP-tagged proteins via a polyethylene glycol linker preserving the functionality of the coupled proteins. The procedure combines well-established protocols, is highly reproducible, reliable, and can be used for a large variety of proteins. The coupling is efficient and can be tuned to the desired microsphere-to-protein ratio. Moreover, microspheres hardly cluster or adhere to surfaces. Furthermore, the procedure can be adapted to different tags providing flexibility and a promising attachment strategy for any tagged protein.

  14. Melatonin Nanoparticles Adsorbed to Polyethylene Glycol Microspheres as Activators of Human Colostrum Macrophages

    Directory of Open Access Journals (Sweden)

    Cristiane de Castro Pernet Hara

    2013-01-01

    Full Text Available The effectiveness of hormones associated with polymeric matrices has amplified the possibility of obtaining new drugs to activate the immune system. Melatonin has been reported as an important immunomodulatory agent that can improve many cell activation processes. It is possible that the association of melatonin with polymers could influence its effects on cellular function. Thus, this study verified the adsorption of the hormone melatonin to polyethylene glycol (PEG microspheres and analyzed its ability to modulate the functional activity of human colostrum phagocytes. Fluorescence microscopy and flow cytometry analyses revealed that melatonin was able to adsorb to the PEG microspheres. This system increased the release of superoxide and intracellular calcium. There was an increase of phagocytic and microbicidal activity by colostrum phagocytes when in the presence of melatonin adsorbed to PEG microspheres. The modified delivery of melatonin adsorbed to PEG microspheres may be an additional mechanism for its microbicidal activity and represents an important potential treatment for gastrointestinal infections of newborns.

  15. Melatonin Nanoparticles Adsorbed to Polyethylene Glycol Microspheres as Activators of Human Colostrum Macrophages

    International Nuclear Information System (INIS)

    Hara, C.D.C.P.; Honorio-Frana, A.C.; Fagundes, D.L.G.; Guimares, P.C.L.; Franca, E.L.

    2013-01-01

    The effectiveness of hormones associated with polymeric matrices has amplified the possibility of obtaining new drugs to activate the immune system. Melatonin has been reported as an important immunomodulatory agent that can improve many cell activation processes. It is possible that the association of melatonin with polymers could influence its effects on cellular function. Thus, this study verified the adsorption of the hormone melatonin to polyethylene glycol (PEG) microspheres and analyzed its ability to modulate the functional activity of human colostrum phagocytes. Fluorescence microscopy and flow cytometry analyses revealed that melatonin was able to adsorb to the PEG microspheres. This system increased the release of superoxide and intracellular calcium. There was an increase of phagocytic and microbicidal activity by colostrum phagocytes when in the presence of melatonin adsorbed to PEG microspheres. The modified delivery of melatonin adsorbed to PEG microspheres may be an additional mechanism for its microbicidal activity and represents an important potential treatment for gastrointestinal infections of newborns.

  16. Fabrication of a multiplexed microfluidic system for scaled up production of cross-linked biocatalytic microspheres

    CSIR Research Space (South Africa)

    Mbanjwa, M

    2014-06-01

    Full Text Available the design and fabrication of a multiplexed microfluidic system for producing biocatalytic microspheres. The microfluidic system consists of an array of 10 parallel microfluidic circuits, for simultaneous operation to demonstrate increased production...

  17. Fiber pigtailed thin wall capillary coupler for excitation of microsphere WGM resonator.

    Science.gov (United States)

    Wang, Hanzheng; Lan, Xinwei; Huang, Jie; Yuan, Lei; Kim, Cheol-Woon; Xiao, Hai

    2013-07-01

    In this paper, we demonstrate a fiber pigtailed thin wall capillary coupler for excitation of Whispering Gallery Modes (WGMs) of microsphere resonators. The coupler is made by fusion-splicing an optical fiber with a capillary tube and consequently etching the capillary wall to a thickness of a few microns. Light is coupled through the peripheral contact between inserted microsphere and the etched capillary wall. The coupling efficiency as a function of the wall thickness was studied experimentally. WGM resonance with a Q-factor of 1.14 × 10(4) was observed using a borosilicate glass microsphere with a diameter of 71 μm. The coupler operates in the reflection mode and provides a robust mechanical support to the microsphere resonator. It is expected that the new coupler may find broad applications in sensors, optical filters and lasers.

  18. Application of magnetic poly(styrene-glycidyl methacrylate) microspheres for immunomagnetic separation of bone marrow cells

    Energy Technology Data Exchange (ETDEWEB)

    Chung, T.-H.; Chang, J.-Y. [Department of Chemical Engineering, National Chung Cheng University, Chiayi 621, Taiwan (China); Lee, W.-C. [Department of Chemical Engineering, National Chung Cheng University, Chiayi 621, Taiwan (China)], E-mail: chmwcl@ccu.edu.tw

    2009-05-15

    Surface-functionalized magnetic poly(styrene-glycidyl methacrylate) (PS-GMA) microspheres were prepared and coupled with Sca-1 antibody for cell selection from murine bone marrow mononuclear cells (MNCs). Biotinylated Sca-1 antibody could be directly coupled to avidin-bound magnetic microspheres. Alternatively, oxidized goat anti-mouse antibody was covalently bound onto the amino group-containing magnetic microspheres in a site-directed manner, and the resultant conjugate was coupled with non-modified Sca-1 antibody. Using the indirect antibody-bound magnetic microspheres, the purity of isolated Sca-1{sup +} cells increased with bead-to-cell ratio. Using a bead-to-cell ratio of 10 beads/cell, a purity of 85% Sca-1{sup +} cells corresponding to a 17-fold enrichment was achieved.

  19. Preoperational test report, recirculation condenser cooling systems

    International Nuclear Information System (INIS)

    Clifton, F.T.

    1997-01-01

    This represents a preoperational test report for Recirculation Condenser Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The four system provide condenser cooling water for vapor space cooling of tanks AY1O1, AY102, AZ1O1, AZ102. Each system consists of a valved piping loop, a pair of redundant recirculation pumps, a closed-loop evaporative cooling tower, and supporting instrumentation; equipment is located outside the farm on concrete slabs. Piping is routed to the each ventilation condenser inside the farm via below-grade concrete trenches. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System

  20. Preoperational test report, recirculation condenser cooling systems

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-11-04

    This represents a preoperational test report for Recirculation Condenser Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The four system provide condenser cooling water for vapor space cooling of tanks AY1O1, AY102, AZ1O1, AZ102. Each system consists of a valved piping loop, a pair of redundant recirculation pumps, a closed-loop evaporative cooling tower, and supporting instrumentation; equipment is located outside the farm on concrete slabs. Piping is routed to the each ventilation condenser inside the farm via below-grade concrete trenches. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  1. Preoperative nuclear scans in patients with melanoma

    International Nuclear Information System (INIS)

    Au, F.C.; Maier, W.P.; Malmud, L.S.; Goldman, L.I.; Clark, W.H. Jr.

    1984-01-01

    One hundred forty-one liver scans, 137 brain scans, and 112 bone scans were performed in 192 patients with clinical Stage 1 melanoma. One liver scan was interpreted as abnormal; liver biopsy of that patient showed no metastasis. There were 11 suggestive liver scans; three of the patients with suggestive liver scans had negative liver biopsies. The remaining eight patients were followed from 4 to 6 years and none of those patients developed clinical evidence of hepatic metastases. All of the brain scans were normal. Five patients had suggestive bone scans and none of those patients had manifested symptoms of osseous metastases with a follow-up of 2 to 4.5 years. This study demonstrates that the use of preoperative liver, brain and bone scan in the evaluation of patients with clinical Stage 1 melanoma is virtually unproductive

  2. Preoperative and intraoperative irradiation for osteosarcoma

    International Nuclear Information System (INIS)

    Furuya, Kotaro; Amino, Katsuhisa; Kawaguchi, Noriyoshi.

    1980-01-01

    1) 8 cases of osteosarcoma were treated with preoperative massive irradiation, the over 5 years survival rate was 3/8 (37.5%). 7 out of 8 cases (87.5%) metastasized to the lung. From these result, it is considered that tumorspecific immunological effect can not be expected from irradiation. Irradiation therapy is essentially a local treatment, and therefore systemic chemotherapy is necessary to prevent metastasis. 2) Osteosarcoma was considered to be radioresistant tumor previously, however local control can be obtained by direct view irradiation without the damage of surrounding tissue. This irradiation method is indicated only for young adult in whom the primary tumor is localized. 3) In the experimental study on heterotransplanted human osteosarcoma in nude mice, combined treatment with radiation and chemotherapy (HD-MTX, ADM and EDX) was proven to be more effective as compared with radiation alone. (author)

  3. Pre-operative optimisation of lung function

    Directory of Open Access Journals (Sweden)

    Naheed Azhar

    2015-01-01

    Full Text Available The anaesthetic management of patients with pre-existing pulmonary disease is a challenging task. It is associated with increased morbidity in the form of post-operative pulmonary complications. Pre-operative optimisation of lung function helps in reducing these complications. Patients are advised to stop smoking for a period of 4–6 weeks. This reduces airway reactivity, improves mucociliary function and decreases carboxy-haemoglobin. The widely used incentive spirometry may be useful only when combined with other respiratory muscle exercises. Volume-based inspiratory devices have the best results. Pharmacotherapy of asthma and chronic obstructive pulmonary disease must be optimised before considering the patient for elective surgery. Beta 2 agonists, inhaled corticosteroids and systemic corticosteroids, are the main drugs used for this and several drugs play an adjunctive role in medical therapy. A graded approach has been suggested to manage these patients for elective surgery with an aim to achieve optimal pulmonary function.

  4. Morphogenesis and crystallization of ZnS microspheres by a soft template-assisted hydrothermal route: synthesis, growth mechanism, and oxygen sensitivity.

    Science.gov (United States)

    Yang, Liangbao; Han, Jun; Luo, Tao; Li, Minqiang; Huang, Jiarui; Meng, Fanli; Liu, Jinhuai

    2009-01-05

    Almost monodisperse ZnS microspheres have been synthesized on a large scale by a hydrothermal route, in which tungstosilicate acid (TSA) was used as a soft template. By controlling the reaction conditions, such as reaction temperature, pH value of the solutions, and the reaction medium, almost monodisperse microspheres can be synthesized. The structure of these microspheres is sensitive to the reaction conditions. The growth mechanism of these nearly monodisperse microspheres was examined. Oxygen sensing is realized from ZnS microspheres. The current through the ZnS microspheres under UV illumination increases as the oxygen concentration decreases.

  5. Mucoadhesive microspheres for gastroretentive delivery of acyclovir: in vitro and in vivo evaluation.

    Science.gov (United States)

    Dhaliwal, Sumeet; Jain, Subheet; Singh, Hardevinder P; Tiwary, A K

    2008-06-01

    The aim of the present investigation was to evaluate the potential use of mucoadhesive microspheres for gastroretentive delivery of acyclovir. Chitosan, thiolated chitosan, Carbopol 71G and Methocel K15M were used as mucoadhesive polymers. Microsphere formulations were prepared using emulsion-chemical crosslinking technique and evaluated in vitro, ex-vivo and in-vivo. Gelatin capsules containing drug powder showed complete dissolution (90.5 +/- 3.6%) in 1 h. The release of drug was prolonged to 12 h (78.8 +/- 3.9) when incorporated into mucoadhesive microspheres. The poor bioavailability of acyclovir is attributed to short retention of its dosage form at the absorption sites (in upper gastrointestinal tract to duodenum and jejunum). The results of mucoadhesion study showed better retention of thiolated chitosan microspheres (8.0 +/- 0.8 h) in duodenal and jejunum regions of intestine. The results of qualitative and quantitative GI distribution study also showed significant higher retention of mucoadhesive microspheres in upper GI tract. Pharmacokinetic study revealed that administration of mucoadhesive microspheres could maintain measurable plasma concentration of acyclovir through 24 h, as compared to 5 h after its administration in solution form. Thiolated chitosan microsphere showed superiority over the other formulations as observed with nearly 4.0-fold higher AUC(0-24) value (1,090 +/- 51 ng h/ml) in comparison to drug solution (281 +/- 28 ng h/ml). Overall, the result indicated prolonged delivery with significant improvement in oral bioavailability of acyclovir from mucoadhesive microspheres due to enhanced retention in the upper GI tract.

  6. Synthesis and photocatalytic properties of different SnO{sub 2} microspheres on graphene oxide sheets

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Jia, E-mail: jojo.1125@hotmail.com [College of Science, Donghua University, Shanghai 201620 (China); Xue, Shaolin, E-mail: slxue@dhu.edu.cn [College of Science, Donghua University, Shanghai 201620 (China); Xie, Pei, E-mail: peipeixie@sina.com [College of Science, Donghua University, Shanghai 201620 (China); Zou, Rujia, E-mail: rujiazou@dhu.edu.cn [College of Science, Donghua University, Shanghai 201620 (China); State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620 (China)

    2016-07-15

    Highlights: • Different SnO{sub 2} microspheres were grown on GOs by hydrothermal method. • The morphology was influenced by volume ratio of ethanol and concentrations of precursor. • The shape of SnO{sub 2} microspheres looks like dandelion. • The photocatalytic property is strongly influenced by the SnO{sub 2} morphology on GOs. - Abstract: Different SnO{sub 2} microspheres like dandelions, silkworm cocoons and urchins have been synthesized on graphene oxide sheets (GOs) by hydrothermal method at 190 °C for 24 h. The morphologies, structures, chemical compositions and optical properties of the as-grown SnO{sub 2} microspheres on GOs (SMGs) were characterized by X-ray diffractometer (XRD), X-ray photoelectron spectroscopy (XPS), scanning electron microscope (SEM), X-ray energy dispersive spectrometer (EDS), Raman spectra and UV–vis diffuse reflectance spectra (DRS) techniques. The results of XRD revealed that the as-grown SnO{sub 2} microspheres have tetragonal rutile structure. The results of Raman spectra, EDS, XRD, XPS and SEM showed that the SnO{sub 2} microspheres were grown on GOs and the average diameter of dandelion-like microsphere was about 1.5 μm. The formation mechanism of SnO{sub 2} microspheres grown on GOs was discussed. The photocatalytic activity of the SMGs composites was evaluated by photocatalytic degradation of Rhodamine B (Rh B) aqueous solution under visible light irradiation. The photocatalytic results showed that the dandelion-like SMGs exhibited a much better photocatalytic activity than those of smooth and rough SMGs.

  7. Synthesis and photocatalytic properties of different SnO2 microspheres on graphene oxide sheets

    International Nuclear Information System (INIS)

    Wei, Jia; Xue, Shaolin; Xie, Pei; Zou, Rujia

    2016-01-01

    Highlights: • Different SnO 2 microspheres were grown on GOs by hydrothermal method. • The morphology was influenced by volume ratio of ethanol and concentrations of precursor. • The shape of SnO 2 microspheres looks like dandelion. • The photocatalytic property is strongly influenced by the SnO 2 morphology on GOs. - Abstract: Different SnO 2 microspheres like dandelions, silkworm cocoons and urchins have been synthesized on graphene oxide sheets (GOs) by hydrothermal method at 190 °C for 24 h. The morphologies, structures, chemical compositions and optical properties of the as-grown SnO 2 microspheres on GOs (SMGs) were characterized by X-ray diffractometer (XRD), X-ray photoelectron spectroscopy (XPS), scanning electron microscope (SEM), X-ray energy dispersive spectrometer (EDS), Raman spectra and UV–vis diffuse reflectance spectra (DRS) techniques. The results of XRD revealed that the as-grown SnO 2 microspheres have tetragonal rutile structure. The results of Raman spectra, EDS, XRD, XPS and SEM showed that the SnO 2 microspheres were grown on GOs and the average diameter of dandelion-like microsphere was about 1.5 μm. The formation mechanism of SnO 2 microspheres grown on GOs was discussed. The photocatalytic activity of the SMGs composites was evaluated by photocatalytic degradation of Rhodamine B (Rh B) aqueous solution under visible light irradiation. The photocatalytic results showed that the dandelion-like SMGs exhibited a much better photocatalytic activity than those of smooth and rough SMGs.

  8. Polydimethylsiloxane microspheres with poly(methyl methacrylate) coating: Modelling, preparation, and characterization

    OpenAIRE

    Ma, Baoguang; Hansen, Jens Henrik; Hvilsted, Søren; Skov, Anne Ladegaard

    2015-01-01

    Polydimethylsiloxane (PDMS) microspheres are prepared by mixing homogeneous dispersions of vinyl-functional PDMS and a curing agent using mechanical stirring in a series of aqueous solutions, and curing at 80 8C for 2 h. In order to verify the experimental diameter and size distributions of the PDMS microspheres, the Hinze-Kolmogorov theory is applied to predict the mean diameter, and a population balance model as well as the maximum entropy formalism are used to describe the size distributio...

  9. Hierarchical CuO hollow microspheres: Controlled synthesis for enhanced lithium storage performance

    International Nuclear Information System (INIS)

    Guan Xiangfeng; Li Liping; Li Guangshe; Fu Zhengwei; Zheng Jing; Yan Tingjiang

    2011-01-01

    Graphical abstract: Hierarchical CuO microspheres with hollow interiors were formed through self-wrapping of a single layer of radically oriented CuO nanorods, and these microspheres showed excellent cycle performance and enhanced lithium storage capacity. Display Omitted Research highlights: → Hierarchical CuO hollow microspheres were prepared by a hydrothermal method. → The CuO hollow microspheres were assembled from radically oriented nanorods. → The growth mechanism was proposed to proceed via self-assembly and Ostwald's ripening. → The microspheres showed good cycle performance and enhanced lithium storage capacity. → Hierarchical microstructures with hollow interiors promote electrochemical property. - Abstract: In this work, hierarchical CuO hollow microspheres were hydrothermally prepared without use of any surfactants or templates. By controlling the formation reaction conditions and monitoring the relevant reaction processes using time-dependent experiments, it is demonstrated that hierarchical CuO microspheres with hollow interiors were formed through self-wrapping of a single layer of radically oriented CuO nanorods, and that hierarchical spheres could be tuned to show different morphologies and microstructures. As a consequence, the formation mechanism was proposed to proceed via a combined process of self-assembly and Ostwald's ripening. Further, these hollow microspheres were initiated as the anode material in lithium ion batteries, which showed excellent cycle performance and enhanced lithium storage capacity, most likely because of the synergetic effect of small diffusion lengths in building blocks of nanorods and proper void space that buffers the volume expansion. The strategy reported in this work is reproducible, which may help to significantly improve the electrochemical performance of transition metal oxide-based anode materials via designing the hollow structures necessary for developing lithium ion batteries and the relevant

  10. Self-Assembly of pH-Responsive Microspheres for Intestinal Delivery of Diverse Lipophilic Therapeutics.

    Science.gov (United States)

    Zhou, Xing; Zhao, Yang; Chen, Siyu; Han, Songling; Xu, Xiaoqiu; Guo, Jiawei; Liu, Mengyu; Che, Ling; Li, Xiaohui; Zhang, Jianxiang

    2016-08-08

    Targeted delivery of therapeutics to the intestine is preferred for the management of many diseases due to its diverse advantages. Currently, there are still challenges in creating cost-effective and translational pH-responsive microspheres for intestinal delivery of various hydrophobic drugs. Herein we report a multiple noncovalent interactions-mediated assembly strategy in which carboxyl-bearing compounds (CBCs) are guest molecules, while poly(N-isopropylacrylamide) (PNIPAm) serves as a host polymer. Formation of microparticles and therapeutic packaging can be achieved simultaneously by this assembly approach, leading to well-shaped microspheres with extremely higher drug loading capacity as compared to microspheres based on two FDA-approved materials of poly(d,l-lactide-co-glycolide) (PLGA) and an enteric coating polymer EudragitS 100 (S100). Also, carboxyl-deficient hydrophobic drugs can be effectively entrapped. These assembled microspheres, with excellent reconstitution capability as well as desirable scalability, could selectively release drug molecules under intestinal conditions. By significantly enhancing drug dissolution/release in the intestine, these pH-responsive assemblies may notably improve the oral bioavailability of loaded therapeutics. Moreover, the assembled microspheres possessed superior therapeutic performance in rodent models of inflammation and tumor over the control microspheres derived from PLGA and S100. Therapy with newly developed microspheres did not cause undesirable side effects. Furthermore, in vivo evaluation in mice revealed the carrier material PNIPAm was safe for oral delivery at doses as high as 10 g/kg. Collectively, our findings demonstrated that this type of pH-responsive microsphere may function as superior and translational intestine-directed delivery systems for a diverse array of therapeutics.

  11. Analytical advantages of copolymeric microspheres for fluorimetric sensing - tuneable sensitivity sensors and titration agents.

    Science.gov (United States)

    Stelmach, Emilia; Maksymiuk, Krzysztof; Michalska, Agata

    2017-01-15

    Analytical benefits related to application of copolymeric microspheres containing different number of carboxylic acid mers have been studied on example of acrylate copolymers. These structures can be used as a reagent in heterogeneous pH titration, benefiting from different number of reactive groups - i.e. different concentration of a titrant - within the series of copolymers. Thus introducing the same amount of different microspheres from a series to the sample, different amount of the titrant is introduced. Copolymeric microspheres also can be used as optical sensors - in this respect the increasing number of reactive groups in the series is useful to improve the analytical performance of microprobes - sensitivity of determination or/and response range. The increase in ion-permeability of the spheres with increasing number of reactive mers is advantageous. It is shown that for pH sensitive microspheres containing higher number of carboxyl groups the higher sensitivity for alkaline pH samples is observed for an indicator present in the beads. The significant increase of optical responses is related to enhanced ion transport within the microspheres. For zinc or potassium ions model sensors tested it was shown that by choice of pH conditions and type of microspheres from the series, the optical responses can be tuned - to enhance sensitivity for analyte concentration change as well as to change the response pattern from sigmoidal (higher sensitivity, narrow range) to linear (broader response range). For classical optode systems (e.g. microspheres containing an optical transducer - pH sensitive dye and optically silent ionophore - receptor) copolymeric microspheres containing carboxylic acid mers in their structure allow application of the sensor in alkaline pH range, which is usually inaccessible for applied optical transducer. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Comparison of the xenon-133 washout method with the microsphere method in dog brain perfusion studies

    International Nuclear Information System (INIS)

    Heikkitae, J.; Kettunen, R.; Ahonen, A.

    1982-01-01

    The validity of the Xenon-washout method in estimation of regional cerebral blood flow was tested against a radioactive microsphere method in anaesthetized dogs. The two compartmental model seemed not to be well suited for cerebral perfusion studies by Xe-washout method, although bi-exponential analysis of washout curves gave perfusion values correlating with the microsphere method but depending on calculation method

  13. Effect of crosslinking agents on chitosan microspheres in controlled release of diclofenac sodium

    OpenAIRE

    Gonçalves,Vanessa L.; Laranjeira,Mauro C. M.; Fávere,Valfredo T.; Pedrosa,Rozângela C.

    2005-01-01

    In this work chitosan microspheres were prepared by the simple coacervation method and crosslinked using epichlorhydrin or glutaraldehyde for the controlled release of diclofenac sodium. The effects of the crosslinking agents on chitosan microspheres over a 12-hour period were assessed with regard to swelling, hydrolysis, porosity, crosslinking, impregnation of diclofenac sodium (DS), and consequently to the release of DS in buffer solutions, simulating the gastrointestinal tract. The degree ...

  14. Development and evaluation of intestinal targeted mucoadhesive microspheres of Bacillus coagulans.

    Science.gov (United States)

    Alli, Sk Md Athar; Ali, Sk Md Ajhar; Samanta, Amalesh

    2011-11-01

    Intestinal targeted mucoadhesive microsphere of probiotics may provide numerous associated health benefits. To develop mucoadhesive microspheres that will deliver viable probiotic cells into gut protectively against harsh environmental conditions of stomach for extended period. Core mucoadhesive microspheres of Bacillus coagulans were prepared using hypromellose, following coacervation and phase separation technique and were then coated with hypromellose phthalate to achieve their site-specific release. Microspheres were evaluated for percent yield, entrapment efficiency, surface morphology, particle size and size distribution, flow property, swelling property, mucoadhesion property by the in vitro wash-off and the ex vivo mucoadhesive strength tests, in vitro release profile and release kinetic, in vivo probiotic activity, and stability. The values for kinetic constant and regression coefficient of model-dependent approaches and the difference factor, the similarity factor, and the Rescigno index of model-independent approaches were determined for accessing and comparing in vitro performance. Microsphere formulation batches have percent yield value between 56.26% and 69.13% and entrapment efficiency value between 66.95% and 77.89%. Microspheres were coarser with spherical shape having mean particle size from 28.03 to 48.31 μm. In vitro B. coagulans release profile follows zero-order kinetics and depends on the grade of hypromellose and the B. coagulans-to-hypromellose ratio. Experimental microspheres rendered adequate stability to B. coagulans at room temperature. Microspheres had delivered B. coagulans in simulated intestinal condition following zero-order kinetics, protectively in simulated gastric condition, exhibiting appreciable mucoadhesion in intestinal condition, which could be useful to achieve site-specific delivery for extended period.

  15. Microspheres for the Growth of Silicon Nanowires via Vapor-Liquid-Solid Mechanism

    Directory of Open Access Journals (Sweden)

    Arancha Gómez-Martínez

    2014-01-01

    Full Text Available Silicon nanowires have been synthesized by a simple process using a suitable support containing silica and carbon microspheres. Nanowires were grown by thermal chemical vapor deposition via a vapor-liquid-solid mechanism with only the substrate as silicon source. The curved surface of the microsized spheres allows arranging the gold catalyst as nanoparticles with appropriate dimensions to catalyze the growth of nanowires. The resulting material is composed of the microspheres with the silicon nanowires attached on their surface.

  16. Confocal microscopy and spectroscopy of nanocrystals on a high-Q microsphere resonator

    International Nuclear Information System (INIS)

    Goetzinger, S; Menezes, L de S; Benson, O; Talapin, D V; Gaponik, N; Weller, H; Rogach, A L; Sandoghdar, V

    2004-01-01

    We report on experiments where we used a home-made confocal microscope to excite single nanocrystals on a high-Q microsphere resonator. In that way spectra of an individual quantum emitter could be recorded. The Q factor of the microspheres coated with nanocrystals was still up to 10 9 . We also demonstrate the use of a prism coupler as a well-defined output port to collect the fluorescence of an ensemble of nanocrystals coupled to whispering-gallery modes

  17. Background parenchymal enhancement in preoperative breast MRI.

    Science.gov (United States)

    Kohara, Satoko; Ishigaki, Satoko; Satake, Hiroko; Kawamura, Akiko; Kawai, Hisashi; Kikumori, Toyone; Naganawa, Shinji

    2015-08-01

    We aimed to assess the influence of background parenchymal enhancement (BPE) on surgical planning performed using preoperative MRI for breast cancer evaluation. Between January 2009 and December 2010, 91 newly diagnosed breast cancer patients (mean age, 55.5 years; range, 30-88 years) who underwent preoperative bilateral breast MRI followed by planned breast conservation therapy were retrospectively enrolled. MRI was performed to assess the tumor extent in addition to mammography and breast ultrasonography. BPE in the contralateral normal breast MRI at the early dynamic phase was visually classified as follows: minimal (n=49), mild (n=27), moderate (n=7), and marked (n=8). The correlations between the BPE grade and age, menopausal status, index tumor size, changes in surgical management based on MRI results, positive predictive value (PPV) of MRI, and surgical margins were assessed. Patients in the strong BPE groups were significantly younger (p=0.002) and generally premenopausal (p<0.001). Surgical treatment was not changed in 67 cases (73.6%), while extended excision and mastectomy were performed in 12 cases (13.2%), each based on additional lesions on MRI. Six of 79 (7.6%) patients who underwent breast conservation therapy had tumor-positive resection margins. In cases where surgical management was changed, the PPV for MRI-detected foci was high in the minimal (91.7%) and mild groups (66.7%), and 0% in the moderate and marked groups (p=0.002). Strong BPE causes false-positive MRI findings and may lead to overly extensive surgery, whereas MRI may be beneficial in select patients with weak BPE.

  18. Preoperative information needs of children undergoing tonsillectomy.

    LENUS (Irish Health Repository)

    Buckley, Aoife

    2012-02-01

    AIMS AND OBJECTIVES: To identify the information needs of children undergoing tonsillectomy with reference to content of information, method of delivery, information providers and timing of information provision. BACKGROUND: Tonsillectomy can be anxiety provoking for children and preoperative preparation programmes are long recognised to reduce anxiety. However, few have been designed from the perspectives of children and to date little is known about how best to prepare children in terms of what to tell them, how to convey information to them, who can best provide information and what is the best timing for information provision. DESIGN: A qualitative descriptive study. METHOD: Data were collected from nine children (aged 6-9) using interviews supported by a write and draw technique. Data were coded and categorised into themes reflecting content, method, providers and timing of information. RESULTS: Children openly communicated their information needs especially on what to tell them to expect when facing a tonsillectomy. Their principal concerns were about operation procedures, experiencing \\'soreness\\' and discomfort postoperatively and parental presence. Mothers were viewed as best situated to provide them with information. Children were uncertain about what method of information and timing would be most helpful to them. CONCLUSION: Preoperative educational interventions need to take account of children\\'s information needs so that they are prepared for surgery in ways that are meaningful and relevant to them. Future research is needed in this area. RELEVANCE TO CLINICAL PRACTICE: Practical steps towards informing children about having a tonsillectomy include asking them what they need to know and addressing their queries accordingly. Child-centred information leaflets using a question and answer format could also be helpful to children.

  19. Preparation and Characterization of Zein and Zein-Chitosan Microspheres with Great Prospective of Application in Controlled Drug Release

    Directory of Open Access Journals (Sweden)

    Vinícius Müller

    2011-01-01

    Full Text Available Biomaterials applied as carriers for controlled drug delivery offer many advantages over the conventional systems. Among them, the increase of treatment effectiveness and also a significant reduction of toxicity, due to their biodegradability property, are some special features. In this work, microspheres based on the protein Zein (ZN and ZN associated to the natural polymer Chitosan (CHI were prepared and characterized. The microspheres of ZN and ZN/CHI were characterized by FT-IR spectroscopy and thermal analysis, and the morphology was analyzed by SEM images. The results confirmed the incorporation of CHI within the ZN-based microspheres. The morphological analysis showed that the CHI added increased the microspheres porosity when compared to the ZN microspheres. The chemical and physical characterization and the morphological analysis allow inferring that ZN/CHI microspheres are good candidates to act as a carrier for controlled drug release.

  20. The influence of increased cross-linker chain length in thermosensitive microspheres on potential sun-protection activity.

    Science.gov (United States)

    Musiał, Witold; Kokol, Vanja; Voncina, Bojana

    2010-01-01

    The sun protection should involve substances with protecting activity against both UVB and UVA radiation. In this research the evaluation of thermosensitive microspheres as potential molecules for sunscreen formulations was approached, using modified Boots star rating system. The microspheres, thermosensitive N-isopropylacrylamide derivatives, have potential protecting activity against UV radiation. The MX and DX microspheres, with ethylene glycol dimethacrylate and diethylene glycol dimethacrylate crosslinker respectively, due to theirs thermosensitivity exhibit increase in protecting activity against UV radiation when heated to 45 degrees C. The MX microspheres have higher increase in terms of UV absorbance, comparing to DX microspheres, when heated in the 25 degrees C to 45 degrees C range. Studied microspheres have high potential for application as components of sun-screens used in elevated temperatures.

  1. Synthesis and photocatalytic properties of different SnO2 microspheres on graphene oxide sheets

    Science.gov (United States)

    Wei, Jia; Xue, Shaolin; Xie, Pei; Zou, Rujia

    2016-07-01

    Different SnO2 microspheres like dandelions, silkworm cocoons and urchins have been synthesized on graphene oxide sheets (GOs) by hydrothermal method at 190 °C for 24 h. The morphologies, structures, chemical compositions and optical properties of the as-grown SnO2 microspheres on GOs (SMGs) were characterized by X-ray diffractometer (XRD), X-ray photoelectron spectroscopy (XPS), scanning electron microscope (SEM), X-ray energy dispersive spectrometer (EDS), Raman spectra and UV-vis diffuse reflectance spectra (DRS) techniques. The results of XRD revealed that the as-grown SnO2 microspheres have tetragonal rutile structure. The results of Raman spectra, EDS, XRD, XPS and SEM showed that the SnO2 microspheres were grown on GOs and the average diameter of dandelion-like microsphere was about 1.5 μm. The formation mechanism of SnO2 microspheres grown on GOs was discussed. The photocatalytic activity of the SMGs composites was evaluated by photocatalytic degradation of Rhodamine B (Rh B) aqueous solution under visible light irradiation. The photocatalytic results showed that the dandelion-like SMGs exhibited a much better photocatalytic activity than those of smooth and rough SMGs.

  2. BMP2-loaded hollow hydroxyapatite microspheres exhibit enhanced osteoinduction and osteogenicity in large bone defects.

    Science.gov (United States)

    Xiong, Long; Zeng, Jianhua; Yao, Aihua; Tu, Qiquan; Li, Jingtang; Yan, Liang; Tang, Zhiming

    2015-01-01

    The regeneration of large bone defects is an osteoinductive, osteoconductive, and osteogenic process that often requires a bone graft for support. Limitations associated with naturally autogenic or allogenic bone grafts have demonstrated the need for synthetic substitutes. The present study investigates the feasibility of using novel hollow hydroxyapatite microspheres as an osteoconductive matrix and a carrier for controlled local delivery of bone morphogenetic protein 2 (BMP2), a potent osteogenic inducer of bone regeneration. Hollow hydroxyapatite microspheres (100±25 μm) with a core (60±18 μm) and a mesoporous shell (180±42 m(2)/g surface area) were prepared by a glass conversion technique and loaded with recombinant human BMP2 (1 μg/mg). There was a gentle burst release of BMP2 from microspheres into the surrounding phosphate-buffered saline in vitro within the initial 48 hours, and continued at a low rate for over 40 days. In comparison with hollow hydroxyapatite microspheres without BMP2 or soluble BMP2 without a carrier, BMP2-loaded hollow hydroxyapatite microspheres had a significantly enhanced capacity to reconstitute radial bone defects in rabbit, as shown by increased serum alkaline phosphatase; quick and complete new bone formation within 12 weeks; and great biomechanical flexural strength. These results indicate that BMP2-loaded hollow hydroxyapatite microspheres could be a potential new option for bone graft substitutes in bone regeneration.

  3. A new rat model of portal hypertension induced by intraportal injection of microspheres

    Science.gov (United States)

    Li, Xiang-Nong; Benjamin, IS; Alexander, B

    1998-01-01

    AIM: To produce a new rat model of portal hypertension by intraportal injection of microspheres. METHODS: Measured aliquots of single or different-sized microspheres (15, 40, 80μm) were injected into the portal vein to block intrahepatic portal radicals. The resultant changes in arterial,portal,hepatic venous and splenic pulp pressures were monitored. The liver and lungs were excised for histological examination. RESULTS: Portal venous pressure was elevated from basal value of 0.89-1.02 kPa to a steady-state of 1.98-3.19 kPa following the sequential injections of single- or different-sized microspheres, with a markedly lowered mean arterial pressure. However, a small-dose injection of 80 μm microspheres (1.8 × 105) produced a steady-state portal venous pressure of 2.53 × 0.17 kPa, and all rats showed normal arterial pressures. In addition, numerous microspheres were found in the lungs in all experimental groups. CONCLUSION: Portal hypertension can be reproduced in rats by intraportal injection of microspheres at a small dose of 80 μm (1.8 × 105). Intrahepatic portal-systemic shunts probably exist in the normal rat liver. PMID:11819236

  4. Evaluation of the Thermosensitive Release Properties of Microspheres Containing an Agrochemical Compound.

    Science.gov (United States)

    Terada, Takatoshi; Ohtsubo, Toshiro; Iwao, Yasunori; Noguchi, Shuji; Itai, Shigeru

    2017-01-01

    The purpose of this study was to develop a deeper understanding of the key physicochemical parameters involved in the release profiles of microsphere-encapsulated agrochemicals at different temperatures. Microspheres consisting of different polyurethanes (PUs) were prepared using our previously reported solventless microencapsulation technique. Notably, these microspheres exhibited considerable differences in their thermodynamic characteristics, including their glass transition temperature (T g ), extrapolated onset temperature (T o ) and extrapolated end temperature (T e ). At test temperatures below the T o of the PU, only 5-10% of the agrochemical was rapidly released from the microspheres within 1 d, and none was released thereafter. However, at test temperatures above the T o of the PU, the rate of agrochemical release gradually increased with increasing temperatures, and the rate of release from the microspheres was dependent on the composition of the PU. Taken together, these results show that the release profiles of the microspheres were dependent on their thermodynamic characteristics and changes in their PU composition.

  5. Preparation and evaluation of enrofloxacin microspheres and tissue distribution in rats.

    Science.gov (United States)

    Yang, Fan; Kang, Jijun; Yang, Fang; Zhao, Zhensheng; Kong, Tao; Zeng, Zhenling

    2015-01-01

    New enrofloxacin microspheres were formulated, and their physical properties, lung-targeting ability, and tissue distribution in rats were examined. The microspheres had a regular and round shape. The mean diameter was 10.06 µm, and the diameter of 89.93% of all microspheres ranged from 7.0 µm to 30.0 µm. Tissue distribution of the microspheres was evaluated along with a conventional enrofloxacin preparation after a single intravenous injection (7.5 mg of enrofloxacin/kg bw). The results showed that the elimination half-life (t1/2β) of enrofloxacin from lung was prolonged from 7.94 h for the conventional enrofloxacin to 13.28 h for the microspheres. Area under the lung concentration versus time curve from 0 h to ∞ (AUC00∞) was increased from 11.66 h·µg/g to 508.00 h·µg/g. The peak concentration (Cmax) in lung was increased from 5.95 µg/g to 93.36 µg/g. Three lung-targeting parameters were further assessed and showed that the microspheres had remarkable lung-targeting capabilities.

  6. Effect of gamma-irradiation on biodegradable microspheres loaded with rasagiline mesylate

    International Nuclear Information System (INIS)

    Fernandez, Marcos; Barcia, Emilia; Negro, Sofia

    2016-01-01

    In the present study, the influence of gamma-irradiation was evaluated on the physicochemical characteristics and in vitro release of rasagiline mesylate (RM), a selective MAO-B inhibitor used in Parkinson's disease, from poly(D,L-lactide-co-glycolide) (PLGA) microspheres. Microspheres were prepared using PLGA 50:50 by the solvent evaporation technique (O/W emulsion). Microspheres were sterilized by gamma-irradiation and their influence was assessed by scanning electron microscopy (SEM), laser light diffraction, differential scanning calorimetry (DSC), X-ray diffraction (XRD), gel permeation chromatography (GPC), encapsulation efficiency (EE) and in vitro drug release. Gamma-irradiation of RM-loaded microspheres did not affect EE, DSC and XRD patterns. After gamma-irradiation, changes on the surface were observed by SEM, but no significant difference in mean particle size was observed. GPC measurements showed a decrease in molecular weight of the polymer after five days of in vitro release. The similarity factor value between irradiated and non-irradiates microspheres was <50, indicating the non-similarity of the release profiles. The sterilization technique had an effect on the integrity of polymeric system, significantly affecting in vitro release of RM from PLGA microspheres. Therefore, from our results we conclude that gamma-irradiation is not a suitable sterilization procedure for this formulation

  7. Biocompatible magnetic and molecular dual-targeting polyelectrolyte hybrid hollow microspheres for controlled drug release.

    Science.gov (United States)

    Du, Pengcheng; Zeng, Jin; Mu, Bin; Liu, Peng

    2013-05-06

    Well-defined biocompatible magnetic and molecular dual-targeting polyelectrolyte hybrid hollow microspheres have been accomplished via the layer-by-layer (LbL) self-assembly technique. The hybrid shell was fabricated by the electrostatic interaction between the polyelectrolyte cation, chitosan (CS), and the hybrid anion, citrate modified ferroferric oxide nanoparticles (Fe3O4-CA), onto the uniform polystyrene sulfonate microsphere templates. Then the magnetic hybrid core/shell composite particles were modified with a linear, functional poly(ethylene glycol) (PEG) monoterminated with a biotargeting molecule (folic acid (FA)). Afterward the dual targeting hybrid hollow microspheres were obtained after etching the templates by dialysis. The dual targeting hybrid hollow microspheres exhibit exciting pH response and stability in high salt-concentration media. Their pH-dependent controlled release of the drug molecule (anticancer drug, doxorubicin (DOX)) was also investigated in different human body fluids. As expected, the cell viability of the HepG2 cells which decreased more rapidly was treated by the FA modified hybrid hollow microspheres rather than the unmodified one in the in vitro study. The dual-targeting hybrid hollow microspheres demonstrate selective killing of the tumor cells. The precise magnetic and molecular targeting properties and pH-dependent controlled release offers promise for cancer treatment.

  8. Preparation and photocatalytic activity of hollow ZnSe microspheres via Ostwald ripening

    International Nuclear Information System (INIS)

    Zhang Lihui; Yang Heqing; Xie Xiaoli; Zhang Fenghua; Li Li

    2009-01-01

    Hollow ZnSe microspheres were prepared via a facile hydrothermal reaction of Zn(AC) 2 .2H 2 O with Na 2 SeO 3 and ethylene glycol in NaOH solution at 180 deg. C for 12 h. The products were characterized by means of X-ray diffraction, scanning electron microscopy, transmission electron microscopy and Raman spectrum. The hollow microspheres with the diameters of about 2 μm are constructed from ZnSe nanoparticles with the cubic zinc blende structure, the size of hollow interiors and constituent ZnSe nanodots can be tuned by changing the reaction time. The hollow microspheres are formed via an Ostwald ripening process. Photoluminescence and photocatalytic activity of the hollow ZnSe microspheres were studied at room temperature. The results indicate that the hollow microspheres constructed from ZnSe nanoparticles display a strong near-band edge emission at 479 nm and a very weak deep defect (DD) related emission at 556 nm and a high photocatalytic activity in the photodegradation of methyl orange. The photodegradation of methyl orange catalyzed by the ZnSe microspheres is a pseudo first-order reaction

  9. Microsphere integrated microfluidic disk: synergy of two techniques for rapid and ultrasensitive dengue detection.

    Science.gov (United States)

    Hosseini, Samira; Aeinehvand, Mohammad M; Uddin, Shah M; Benzina, Abderazak; Rothan, Hussin A; Yusof, Rohana; Koole, Leo H; Madou, Marc J; Djordjevic, Ivan; Ibrahim, Fatimah

    2015-11-09

    The application of microfluidic devices in diagnostic systems is well-established in contemporary research. Large specific surface area of microspheres, on the other hand, has secured an important position for their use in bioanalytical assays. Herein, we report a combination of microspheres and microfluidic disk in a unique hybrid platform for highly sensitive and selective detection of dengue virus. Surface engineered polymethacrylate microspheres with carefully designed functional groups facilitate biorecognition in a multitude manner. In order to maximize the utility of the microspheres' specific surface area in biomolecular interaction, the microfluidic disk was equipped with a micromixing system. The mixing mechanism (microballoon mixing) enhances the number of molecular encounters between spheres and target analyte by accessing the entire sample volume more effectively, which subsequently results in signal amplification. Significant reduction of incubation time along with considerable lower detection limits were the prime motivations for the integration of microspheres inside the microfluidic disk. Lengthy incubations of routine analytical assays were reduced from 2 hours to 5 minutes while developed system successfully detected a few units of dengue virus. Obtained results make this hybrid microsphere-microfluidic approach to dengue detection a promising avenue for early detection of this fatal illness.

  10. Preparation and characterization of alginate microspheres for sustained protein delivery within tissue scaffolds

    International Nuclear Information System (INIS)

    Zhai Peng; Chen, X B; Schreyer, David J

    2013-01-01

    Tissue engineering scaffolds are designed not only to provide structural support for the repair of damaged tissue, but can also serve the function of bioactive protein delivery. Here we present a study on the preparation and characterization of protein-loaded microspheres, either alone or incorporated into mock tissue scaffolds, for sustained protein delivery. Alginate microspheres were prepared by a novel, small-scale water-in-oil emulsion technique and loaded with fluorescently labeled immunoglobulin G (IgG). Microsphere size appears to be influenced by the magnitude and distribution of force generated by mechanical stirring during emulsion. Protein release studies show that sustained IgG release from microspheres could be achieved and that application of a secondary coating of chitosan could further slow the rate of protein release. Preservation of bioactivity of released IgG protein was confirmed using an immunohistochemical assay. When IgG-loaded microspheres were incorporated into mock scaffolds, initial protein release was diminished and the overall time course of release was extended. The present study demonstrates that protein-loaded microspheres can be prepared with a controlled release profile and preserved biological activity, and can be incorporated into scaffolds to achieve sustained and prolonged protein delivery in a tissue engineering application. (paper)

  11. Polyamine/salt-assembled microspheres coated with hyaluronic acid for targeting and pH sensing.

    Science.gov (United States)

    Zhang, Pan; Yang, Hui; Wang, Guojun; Tong, Weijun; Gao, Changyou

    2016-06-01

    The poly(allylamine hydrochloride)/trisodium citrate aggregates were fabricated and further covalently crosslinked via the coupling reaction of carboxylic sites on trisodium citrate with the amine groups on polyamine, onto which poly-L-lysine and hyaluronic acid were sequentially assembled, forming stable microspheres. The pH sensitive dye and pH insensitive dye were further labeled to enable the microspheres with pH sensing property. Moreover, these microspheres could be specifically targeted to HeLa tumor cells, since hyaluronic acid can specifically recognize and bind to CD44, a receptor overexpressed on many tumor cells. Quantitative pH measurement by confocal laser scanning microscopy demonstrated that the microspheres were internalized into HeLa cells, and accumulated in acidic compartments. By contrast, only a few microspheres were adhered on the NIH 3T3 cells surface. The microspheres with combined pH sensing property and targeting ability can enhance the insight understanding of the targeted drug vehicles trafficking after cellular internalization. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Graphene Aerogel Templated Fabrication of Phase Change Microspheres as Thermal Buffers in Microelectronic Devices.

    Science.gov (United States)

    Wang, Xuchun; Li, Guangyong; Hong, Guo; Guo, Qiang; Zhang, Xuetong

    2017-11-29

    Phase change materials, changing from solid to liquid and vice versa, are capable of storing and releasing a large amount of thermal energy during the phase change, and thus hold promise for numerous applications including thermal protection of electronic devices. Shaping these materials into microspheres for additional fascinating properties is efficient but challenging. In this regard, a novel phase change microsphere with the design for electrical-regulation and thermal storage/release properties was fabricated via the combination of monodispersed graphene aerogel microsphere (GAM) and phase change paraffin. A programmable method, i.e., coupling ink jetting-liquid marbling-supercritical drying (ILS) techniques, was demonstrated to produce monodispersed graphene aerogel microspheres (GAMs) with precise size-control. The resulting GAMs showed ultralow density, low electrical resistance, and high specific surface area with only ca. 5% diameter variation coefficient, and exhibited promising performance in smart switches. The phase change microspheres were obtained by capillary filling of phase change paraffin inside the GAMs and exhibited excellent properties, such as low electrical resistance, high latent heat, well sphericity, and thermal buffering. Assembling the phase change microsphere into the microcircuit, we found that this tiny device was quite sensitive and could respond to heat as low as 0.027 J.

  13. Properties of Amorphous Carbon Microspheres Synthesised by Palm Oil-CVD Method

    International Nuclear Information System (INIS)

    Zobir, S. A. M.; Zainal, Z.; Sarijo, S. H.; Rusop, M.

    2011-01-01

    Amorphous carbon microspheres were synthesized using a dual-furnace chemical vapour deposition method at 800-1000 deg. C. Palm oil-based cooking oil (PO) and zinc nitrate solution was used as a carbon source and catalyst precursor, respectively with PO to zinc nitrate ratio of 30:20 (v/v) and a silicon wafer as the sample target. Regular microsphere shape of the amorphous carbons was obtained and a uniform microsphere structure improved as the carbonization temperature increased from 800 to 1000 deg. C. At 800 deg. C, no regular microspheres were formed but more uniform structure is observed at 900 deg. C. Generally the microspheres size is uniform when the heating temperature was increased to 1000 deg. C, but the presence of mixed sizes can still be observed. X-ray diffraction patterns show the presence of oxide of carbon, ZnO phase together with Zn oxalate phase. Raman spectra show two broad peaks characteristic to amorphous carbon at 1344 and 1582 cm -1 for the D and G bands, respectively. These bands become more prominent as the preparation temperature increased from 800 to 1000 deg. C. This is in agreement with the formation of amorphous carbon microspheres as shown by the FESEM study and other Zn-based phases as a result of the oxidation process of the palm oil as the carbon source and the zinc nitrate as the catalyst precursor, respectively.

  14. Biodegradable microsphere-mediated cell perforation in microfluidic channel using femtosecond laser

    Science.gov (United States)

    Ishii, Atsuhiro; Ariyasu, Kazumasa; Mitsuhashi, Tatsuki; Heinemann, Dag; Heisterkamp, Alexander; Terakawa, Mitsuhiro

    2016-05-01

    The use of small particles has expanded the capability of ultrashort pulsed laser optoinjection technology toward simultaneous treatment of multiple cells. The microfluidic platform is one of the attractive systems that has obtained synergy with laser-based technology for cell manipulation, including optoinjection. We have demonstrated the delivery of molecules into suspended-flowing cells in a microfluidic channel by using biodegradable polymer microspheres and a near-infrared femtosecond laser pulse. The use of polylactic-co-glycolic acid microspheres realized not only a higher optoinjection ratio compared to that with polylactic acid microspheres but also avoids optical damage to the microfluidic chip, which is attributable to its higher optical intensity enhancement at the localized spot under a microsphere. Interestingly, optoinjection ratios to nucleus showed a difference for adhered cells and suspended cells. The use of biodegradable polymer microspheres provides high throughput optoinjection; i.e., multiple cells can be treated in a short time, which is promising for various applications in cell analysis, drug delivery, and ex vivo gene transfection to bone marrow cells and stem cells without concerns about residual microspheres.

  15. Preparation of cellulose based microspheres by combining spray coagulating with spray drying.

    Science.gov (United States)

    Wang, Qiao; Fu, Aiping; Li, Hongliang; Liu, Jingquan; Guo, Peizhi; Zhao, Xiu Song; Xia, Lin Hua

    2014-10-13

    Porous microspheres of regenerated cellulose with size in range of 1-2 μm and composite microspheres of chitosan coated cellulose with size of 1-3 μm were obtained through a two-step spray-assisted approach. The spray coagulating process must combine with a spray drying step to guarantee the formation of stable microspheres of cellulose. This approach exhibits the following two main virtues. First, the preparation was performed using aqueous solution of cellulose as precursor in the absence of organic solvent and surfactant; Second, neither crosslinking agent nor separated crosslinking process was required for formation of stable microspheres. Moreover, the spray drying step also provided us with the chance to encapsulate guests into the resultant cellulose microspheres. The potential application of the cellulose microspheres acting as drug delivery vector has been studied in two PBS (phosphate-buffered saline) solution with pH values at 4.0 and 7.4 to mimic the environments of stomach and intestine, respectively. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Electrospray synthesis and properties of hierarchically structured PLGA TIPS microspheres for use as controlled release technologies.

    Science.gov (United States)

    Malik, Salman A; Ng, Wing H; Bowen, James; Tang, Justin; Gomez, Alessandro; Kenyon, Anthony J; Day, Richard M

    2016-04-01

    Microsphere-based controlled release technologies have been utilized for the long-term delivery of proteins, peptides and antibiotics, although their synthesis poses substantial challenges owing to formulation complexities, lack of scalability, and cost. To address these shortcomings, we used the electrospray process as a reproducible, synthesis technique to manufacture highly porous (>94%) microspheres while maintaining control over particle structure and size. Here we report a successful formulation recipe used to generate spherical poly(lactic-co-glycolic) acid (PLGA) microspheres using the electrospray (ES) coupled with a novel thermally induced phase separation (TIPS) process with a tailored Liquid Nitrogen (LN2) collection scheme. We show how size, shape and porosity of resulting microspheres can be controlled by judiciously varying electrospray processing parameters and we demonstrate examples in which the particle size (and porosity) affect release kinetics. The effect of electrospray treatment on the particles and their physicochemical properties are characterized by scanning electron microscopy, confocal Raman microscopy, thermogravimetric analysis and mercury intrusion porosimetry. The microspheres manufactured here have successfully demonstrated long-term delivery (i.e. 1week) of an active agent, enabling sustained release of a dye with minimal physical degradation and have verified the potential of scalable electrospray technologies for an innovative TIPS-based microsphere production protocol. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  17. Production of cerium dioxide microspheres by an internal gelation sol–gel method

    Energy Technology Data Exchange (ETDEWEB)

    Katalenich, Jeffrey A.

    2017-03-27

    An internal gelation sol-gel technique was used to prepare cerium dioxide microspheres with uniform diameters near 100 µm. In this process, chilled aqueous solutions containing cerium, hexamethylenetetramine (HMTA), and urea are transformed into a solid gel by heat addition and are subsequently washed, dried, and sintered to produce pure cerium dioxide. Cerous nitrate and ceric ammonium nitrate solutions were compared for their usefulness in microsphere production. Gelation experiments were performed with both cerous nitrate and ceric ammonium nitrate to determine desirable concentrations of cerium, HMTA, and urea in feed solutions as well as the necessary quantity of ammonium hydroxide added to cerium solutions. Analysis of the pH before and after sample gelation was found to provide a quantitative metric for optimal parameter selection along with subjective evaluations of gel qualities. The time necessary for chilled solutions to gel upon inserting into a hot water bath was determined for samples with a variety of parameters and also used to determine desirable formulations for microsphere production. A technique for choosing the optimal mixture of ceric ammonium nitrate, HMTA, and urea was determined using gelation experiments and used to produce microspheres by dispersion of the feed solution into heated silicone oil. Gelled spheres were washed to remove excess reactants and reaction products before being dried and sintered. X-ray diffraction of air-dried microspheres, sintered microspheres, and commercial CeO2 powders indicated that air-dried and sintered spheres were pure CeO2.

  18. Controlled synthesis of three-dimensional hierarchical Bi2WO6 microspheres with optimum photocatalytic activity

    International Nuclear Information System (INIS)

    Wang, Hong; Song, Jimei; Zhang, Hui; Gao, Fei; Zhao, Shaojuan; Hu, Haiqin

    2012-01-01

    Highlights: ► The synthesized method is very simple. It can be widely used in the production. ► The morphology is novel and the property is fine. ► The formation of 3D hierarchical microsphere can be induced by changing the concentration of KNO 3 . -- Abstract: Three-dimensional (3D) hierarchical Bi 2 WO 6 microsphere and octahedral Bi 2 WO 6 have been synthesized by a facile hydrothermal method using KNO 3 solution and distilled water as solvent, respectively. The obtained products were characterized by X-ray diffraction, scanning electron microscopy, N 2 adsorption/desorption, and UV–vis diffuse reflectance spectroscopy in detail. The concentration of KNO 3 played a key role in the formation of 3D hierarchical Bi 2 WO 6 microspheres. A possible formation mechanism of Bi 2 WO 6 microsphere was proposed. The photocatalytic activity of the as-synthesized products was evaluated by monitoring the degradation of MB solution under sunlight irradiation. It was found that the photocatalytic activity of the 3D hierarchical Bi 2 WO 6 microsphere was superior to the octahedral Bi 2 WO 6 , which was attributed to the larger surface area and special hierarchical structure of Bi 2 WO 6 microsphere.

  19. Use of Novel Polyurethane Microspheres in a Curcumin Delivery System

    Directory of Open Access Journals (Sweden)

    Yongmei Hu

    2014-01-01

    Full Text Available Despite having a wide range of beneficial pharmacological effects, curcumin is characterized by poor water solubility and absorption. In this study, novel polyurethane microspheres containing curcumin (Cur-PUMs were prepared using carboxymethyl cellulose sodium to improve the bioavailability and prolong the retention time of curcumin. The prepared Cur-PUMs were characterized by Fourier transform infrared spectroscopy, scanning electron microscope, and ultraviolet spectrophotometer. The sustained-release effects of Cur-PUMs were demonstrated using stability tests in vitro and in vivo pharmacokinetic studies following oral administration. We found that the stability of Cur-PUMs was strongly affected by pH variation. Further, compared with free curcumin, Cur-PUMs showed significantly improved maximum concentration and half-life.

  20. Preparation of magnetic nanoparticles embedded in polystyrene microspheres

    International Nuclear Information System (INIS)

    Nguyen Hoang Hai; Nguyen Hoang Luong; Nguyen Chau; Ngo Quy Tai

    2009-01-01

    Superparamagnetic particles are widely used for biological applications such as cell separation. The size of the particles is normally in the range of 10 - 20 nm which is much smaller than the size of a cell. Therefore small particles create small force which is not strong enough to separate the cells from solution. Superparamagnetic nanoparticles embedded in Polystyrene microspheres (magnetic beads) are very useful for cell separation. Magnetic beads have been prepared by solvent evaporation of an emulsion. The beads with size of 0.2 μm - 1.0 μm have a saturation magnetization of 10 - 25 emu/g. The change of the amount of surfactants, volatile solvent, magnetic particles resulted to the change of size, magnetic properties of the magnetic beads.