WorldWideScience

Sample records for preoperative y-90 microsphere

  1. 90Y microsphere therapy: does 90Y PET/CT imaging obviate the need for 90Y Bremsstrahlung SPECT/CT imaging?

    Science.gov (United States)

    Zade, Anand A; Rangarajan, Venkatesh; Purandare, Nilendu C; Shah, Sneha A; Agrawal, Archi R; Kulkarni, Suyash S; Shetty, Nitin

    2013-11-01

    Transarterial radioembolization using Y microspheres is a novel therapeutic option for inoperable hepatic malignancies. As these spheres are radiolucent, real-time assessment of their distribution during the infusion process under fluoroscopic guidance is not possible. Bremsstrahlung radiations arising from 90Y have conventionally been used for imaging its biodistribution. Recent studies have proved that sources of 90Y also emit positrons, which can further be used for PET/computed tomography (CT) imaging. This study aimed to assess the feasibility of 90Y PET/CT imaging in evaluating microsphere distributions and to compare its findings with those of Bremsstrahlung imaging. Thirty-five sessions of 90Y microsphere transarterial radioembolization were performed on 30 patients with hepatic malignancies. 90Y PET/CT imaging was performed within 3 h of therapy. Bremsstrahlung imaging was also performed for each patient. The imaging findings were compared for concordance in the distribution of microspheres. Exact one-to-one correspondence between 90Y PET/CT imaging and 90Y Bremsstrahlung imaging was observed in 97.14% of cases (i.e. in 34/35 cases). Discordance was observed only in one case in which 90Y PET/CT imaging resolved the microsphere uptake in the inferior vena cava tumor thrombus, which was, however, not visualized on Bremsstrahlung imaging. There is good concordance in the imaging findings of 90Y PET/CT and 90Y Bremsstrahlung imaging. 90Y PET/CT imaging scores over the conventionally used Bremsstrahlung imaging in terms of better resolution, ease of technique, and comparable image acquisition time. This makes it a preferred imaging modality for assessment of the distribution of 90Y microspheres.

  2. Development of activity standard for 90Y microspheres

    CSIR Research Space (South Africa)

    Mo, L

    2005-08-01

    Full Text Available 90Y is a therapeutic radiopharmaceuticals used in the treatment of liver cancer following implantation via a catheter in the hepatic artery, 90Y microspheres are embolised in the microvasculature of liver cancer where they irradiate the tumour by a...

  3. Preoperative Y-90 microsphere selective internal radiation treatment for tumor downsizing and future liver remnant recruitment: a novel approach to improving the safety of major hepatic resections.

    Science.gov (United States)

    Gulec, Seza A; Pennington, Kenneth; Hall, Michael; Fong, Yuman

    2009-01-08

    Extended liver resections are being performed more liberally than ever. The extent of resection of liver metastases, however, is restricted by the volume of the future liver remnant (FLR). An intervention that would both accomplish tumor control and induce compensatory hypertrophy, with good patient tolerability, could improve clinical outcomes. A 53-year-old woman with a history of cervical cancer presented with a large liver mass. Subsequent biopsy indicated poorly differentiated carcinoma with necrosis suggestive of squamous cell origin. A decision was made to proceed with pre-operative chemotherapy and Y-90 microsphere SIRT with the intent to obtain systemic control over the disease, downsize the hepatic lesion, and improve the FLR. A surgical exploration was performed six months after the first SIRT (three months after the second). There was no extrahepatic disease. The tumor was found to be significantly decreased in size with central and peripheral scarring. The left lobe was satisfactorily hypertrophied. A formal right hepatic lobectomy was performed with macroscopic negative margins. Selective internal radiation treatment (SIRT) with yttrium-90 (Y-90) microspheres has emerged as an effective liver-directed therapy with a favorable therapeutic ratio. We present this case report to suggest that the portal vein radiation dose can be substantially increased with the intent of inducing portal/periportal fibrosis. Such a therapeutic manipulation in lobar Y-90 microsphere treatment could accomplish the end points of PVE with avoidance of the concern regarding tumor progression.

  4. Pilot trial of Y-90 glass microspheres in the treatment of primary hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Houle, S.; Yip, T.C.K.; Shepherd, F.A.; Rotstein, L.E.; Theis, B.; Cawthorn, R.; Barnes, K.

    1987-01-01

    A pilot trial is currently under way at our institution to determine the potential of new Y-90 glass microspheres (Theraspheres, Theragenics Corp., Atlanta) for the treatment of primary hepatocellular carcinoma. The Y-90 microspheres are injected through a percutaneous hepatic artery catheter positioned angiographically. The injection is facilitated by a new delivery system. Prior to the injection of the Y-90 microspheres, the presence of shunting is assessed by injecting Tc-99m human albumin microspheres (HAM) via the hepatic artery catheter. Bremsstrahlung scans done after injection demonstrate the distribution the Y-90 microspheres within the liver and the lack of extrahepatic activity. In the first group of patients treated, no significant toxicity was demonstrated for absorbed doses between 5,000 and 10,000 rad to the liver, and up to 20,000 rad to the tumor itself

  5. Comparative analysis of hepatopulmonary shunt obtained from pretherapy 99mTc MAA scintigraphy and post-therapy 90Y Bremsstrahlung imaging in 90Y microsphere therapy.

    Science.gov (United States)

    Jha, Ashish Kumar A; Zade, Anand A; Rangarajan, Venkatesh; Purandare, Nilendu; Shah, Sneha A; Agrawal, Archi; Kulkarni, Suyash S; Shetty, Nitin

    2012-05-01

    (99m)Tc macroaggregate albumin (MAA) scintigraphy is routinely used to estimate the hepatopulmonary shunt (HPS) of (90)Y microspheres because of their comparable average particle sizes (20-30 µm). However, the MAA particle size can vary from 10 to 90 µm. Therefore, HPS computed from (99m)Tc MAA scintigraphy may not accurately represent the HPS of (90)Y microspheres. In view of this, the present study was undertaken to investigate the accuracy of (99m)Tc MAA scintigraphy in estimating the HPS of (90)Y microspheres. Nineteen sessions of transarterial radioembolization using (90)Y therasphere were carried out in 17 patients for hepatic malignancies (both primary and secondary). For each session of therapy, a pretherapeutic (99m)Tc MAA scintigraphy and post-therapeutic (90)Y Bremsstrahlung scintigraphy were performed. The HPSs obtained from these images were compared. The mean HPS fractions calculated from the pretherapeutic (99m)Tc MAA study and the post-therapeutic (90)Y Bremsstrahlung images were 4.77 ± 2.81 and 4.52 ± 2.5%, respectively. The coefficient of correlation (r) was 0.96. (99m)Tc MAA scintigraphy accurately predicts the HPS of (90)Y microspheres.

  6. Resin 90Y microsphere activity measurements for liver brachytherapy

    International Nuclear Information System (INIS)

    Dezarn, William A.; Kennedy, Andrew S.

    2007-01-01

    The measurement of the radioactivity administered to the patient is one of the major components of 90 Y microsphere liver brachytherapy. The activity of 90 Y microspheres in a glass delivery vial was measured in a dose calibrator. The calibration value to use for 90 Y in the dose calibrator was verified using an activity calibration standard provided by the microsphere manufacturer. This method allowed for the determination of a consistent, reproducible local activity standard. Additional measurements were made to determine some of the factors that could affect activity measurement. The axial response of the dose calibrator was determined by the ratio of activity measurements at the bottom and center of the dose calibrator. The axial response was 0.964 for a glass shipping vial, 1.001 for a glass V-vial, and 0.988 for a polycarbonate V-vial. Comparisons between activity measurements in the dose calibrator and those using a radiation survey meter were found to agree within 10%. It was determined that the dose calibrator method was superior to the survey meter method because the former allowed better defined measurement geometry and traceability of the activity standard back to the manufacturer. Part of the preparation of resin 90 Y microspheres for patient delivery is to draw out a predetermined activity from a shipping vial and place it into a V-vial for delivery to the patient. If the drawn activity was placed in a glass V-vial, the activity measured in the dose calibrator with a glass V-vial was 4% higher than the drawn activity from the shipping vial standard. If the drawn activity was placed in a polycarbonate V-vial, the activity measured in the dose calibrator with a polycarbonate V-vial activity was 20% higher than the drawn activity from the shipping vial standard. Careful characterization of the local activity measurement standard is recommended instead of simply accepting the calibration value of the dose calibrator manufacturer

  7. {sup 90}Y microspheres prepared by sol-gel method, promising medical material for radioembolization of liver malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Łada, Wiesława, E-mail: w.lada@ichtj.waw.pl [Institute of Nuclear Chemistry and Technology, 03-195 Warsaw, Dorodna 16 (Poland); Iller, Edward [National Centre for Nuclear Research, Radioisotope Centre POLATOM, 05-400 Otwock, Andrzej Sołtan 7 (Poland); Wawszczak, Danuta [Institute of Nuclear Chemistry and Technology, 03-195 Warsaw, Dorodna 16 (Poland); Konior, Marcin, E-mail: marcin.konior@polatom.pl [National Centre for Nuclear Research, Radioisotope Centre POLATOM, 05-400 Otwock, Andrzej Sołtan 7 (Poland); Dziel, Tomasz [National Centre for Nuclear Research, Radioisotope Centre POLATOM, 05-400 Otwock, Andrzej Sołtan 7 (Poland)

    2016-10-01

    A new technology for the production of radiopharmaceutical {sup 90}Y microspheres in the form of spherical yttrium oxide grains obtained by sol-gel method has been described. The authors present and discuss the results of investigations performed in the development of new production technology of yttrium microspheres and determination of their physic-chemical properties. The final product has the structure of spherical yttrium oxide grains with a diameter 25–100 μm, is stable and free from contaminants. Irradiation of 20 mg samples of grains with diameter of 20–50 μm in the thermal neutron flux of 1.7 × 10{sup 14} cm{sup −2} s{sup −1} at the core of MARIA research nuclear reactor allowed to obtain microspheres labelled with the {sup 90}Y isotope on the way of the nuclear reaction {sup 89}Y(n, γ){sup 90}Y. Specific activity of irradiated microspheres has been determined by application of absolute triple to double coincidence ratio method (TDCR) and has been evaluated at 190 MBq/mg Y. {sup 90}Y microspheres prepared by the proposed technique can be regarded as a promising medical material for radioembolization of liver malignancies. - Highlights: • Sol-gel methods for preparation of spherical yttrium trioxide grains have been proposed. • Determination condition for irradiation {sup 89}Y{sub 2}O{sub 3} grains in nuclear reactor • Evaluation of specific activity of {sup 90}Y microspheres • Estimation of {sup 90}Y microspheres as promising medical material for radioembolization.

  8. Occupational radiation exposure of medical staff performing 90Y-loaded microsphere radioembolization

    International Nuclear Information System (INIS)

    Laffont, Sophie; Ardisson, Valerie; Lenoir, Laurence; Rolland, Yan; Rohou, Tanguy; Edeline, Julien; Pracht, Marc; Sourd, Samuel Le; Lepareur, Nicolas; Garin, Etienne

    2016-01-01

    Radioembolization of liver cancer with 90 Y-loaded microspheres is increasingly used but data regarding hospital staff exposure are scarce. We evaluated the radiation exposure of medical staff while preparing and injecting 90 Y-loaded glass and resin microspheres especially in view of the increasing use of these products. Exposure of the chest and finger of the radiopharmacist, nuclear medicine physician and interventional radiologist during preparation and injection of 78 glass microsphere preparations and 16 resin microsphere preparations was monitored. Electronic dosimeters were used to measure chest exposure and ring dosimeters were used to measure finger exposure. Chest exposure was very low for both products used (<10 μSv from preparation and injection). In our experience, finger exposure was significantly lower than the annual limit of 500 mSv for both products. With glass microspheres, the mean finger exposure was 13.7 ± 5.2 μSv/GBq for the radiopharmacist, and initially 17.9 ± 5.4 μSv/GBq for the nuclear medicine physician reducing to 13.97 ± 7.9 μSv/GBq with increasing experience. With resin microspheres, finger exposure was more significant: mean finger exposure for the radiopharmacist was 295.1 ± 271.9 μSv/GBq but with a reduction with increasing experience to 97.5 ± 35.2 μSv/GBq for the six most recent dose preparations. For administration of resin microspheres, the greatest mean finger exposure for the nuclear medicine physician (the most exposed operator) was 235.5 ± 156 μSv/GBq. Medical staff performing 90 Y-loaded microsphere radioembolization procedures are exposed to safe levels of radiation. Exposure is lower than that from treatments using 131 I-lipiodol. The lowest finger exposure is from glass microspheres. With resin microspheres finger exposure is acceptable but could be optimized in accordance with the ALARA principle, and especially in view of the increasing use of radioembolization. (orig.)

  9. Histological Comparison of Kidney Tissue Following Radioembolization with Yttrium-90 Resin Microspheres and Embolization with Bland Microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Suresh de, E-mail: suresh.desilva@unsw.edu.au [Southern Radiology Group, Radiology Department Sutherland Hospital (Australia); Mackie, Simon [Western General Hospital, Department of Urology (United Kingdom); Aslan, Peter [St George Hospital, Department of Urology (Australia); Cade, David [Sirtex Technology Pty Ltd (Australia); Delprado, Warick [Douglass Hanly Moir Pathology (Australia)

    2016-12-15

    BackgroundIntra-arterial brachytherapy with yttrium-90 ({sup 90}Y) resin microspheres (radioembolization) is a procedure to selectively deliver high-dose radiation to tumors. The purpose of this research was to compare the radioembolic effect of {sup 90}Y-radioembolization versus the embolic effect of bland microspheres in the porcine kidney model.MethodsIn each of six pigs, ~25–33 % of the kidney volume was embolized with {sup 90}Y resin microspheres and an equivalent number of bland microspheres in the contralateral kidney. Kidney volume was estimated visually from contrast-enhanced fluoroscopy imaging. Morphologic and histologic analysis was performed 8–9 weeks after the procedure to assess the locations of the microspheres and extent of tissue necrosis from {sup 90}Y-radioembolization and bland embolization. A semi-quantified evaluation of the non-acute peri-particle and perivascular tissue reaction was conducted. All guidelines for the care and use of animals were followed.ResultsKidneys embolized with {sup 90}Y-radioembolization decreased in mass by 30–70 % versus the contralateral kidney embolized with bland microspheres. These kidneys showed significant necrosis/fibrosis, avascularization, and glomerular atrophy in the immediate vicinity of the {sup 90}Y resin microspheres. By contrast, glomerular changes were not observed, even with clusters of bland microspheres in afferent arterioles. Evidence of a foreign body reaction was recorded in some kidneys with bland microspheres, and subcapsular scarring/infarction only with the highest load (4.96 × 10{sup 6}) of bland microspheres.ConclusionThis study showed that radioembolization with {sup 90}Y resin microspheres produces localized necrosis/fibrosis and loss of kidney mass in a porcine kidney model. This result supports the study of {sup 90}Y resin microspheres for the localized treatment of kidney tumors.

  10. Histological Comparison of Kidney Tissue Following Radioembolization with Yttrium-90 Resin Microspheres and Embolization with Bland Microspheres

    International Nuclear Information System (INIS)

    Silva, Suresh de; Mackie, Simon; Aslan, Peter; Cade, David; Delprado, Warick

    2016-01-01

    BackgroundIntra-arterial brachytherapy with yttrium-90 ("9"0Y) resin microspheres (radioembolization) is a procedure to selectively deliver high-dose radiation to tumors. The purpose of this research was to compare the radioembolic effect of "9"0Y-radioembolization versus the embolic effect of bland microspheres in the porcine kidney model.MethodsIn each of six pigs, ~25–33 % of the kidney volume was embolized with "9"0Y resin microspheres and an equivalent number of bland microspheres in the contralateral kidney. Kidney volume was estimated visually from contrast-enhanced fluoroscopy imaging. Morphologic and histologic analysis was performed 8–9 weeks after the procedure to assess the locations of the microspheres and extent of tissue necrosis from "9"0Y-radioembolization and bland embolization. A semi-quantified evaluation of the non-acute peri-particle and perivascular tissue reaction was conducted. All guidelines for the care and use of animals were followed.ResultsKidneys embolized with "9"0Y-radioembolization decreased in mass by 30–70 % versus the contralateral kidney embolized with bland microspheres. These kidneys showed significant necrosis/fibrosis, avascularization, and glomerular atrophy in the immediate vicinity of the "9"0Y resin microspheres. By contrast, glomerular changes were not observed, even with clusters of bland microspheres in afferent arterioles. Evidence of a foreign body reaction was recorded in some kidneys with bland microspheres, and subcapsular scarring/infarction only with the highest load (4.96 × 10"6) of bland microspheres.ConclusionThis study showed that radioembolization with "9"0Y resin microspheres produces localized necrosis/fibrosis and loss of kidney mass in a porcine kidney model. This result supports the study of "9"0Y resin microspheres for the localized treatment of kidney tumors.

  11. Clinical feasibility of {sup 90}Y digital PET/CT for imaging microsphere biodistribution following radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Wright, Chadwick L.; Binzel, Katherine; Zhang, Jun; Knopp, Michael V. [The Ohio State University Wexner Medical Center, Wright Center of Innovation in Biomedical Imaging, Department of Radiology, Columbus, OH (United States); Wuthrick, Evan J. [The Ohio State University Wexner Medical Center, Department of Radiation Oncology, Columbus, OH (United States)

    2017-07-15

    The purpose of this study was to evaluate the clinical feasibility of next generation solid-state digital photon counting PET/CT (dPET/CT) technology and imaging findings in patients following {sup 90}Y microsphere radioembolization in comparison with standard of care (SOC) bremsstrahlung SPECT/CT (bSPECT/CT). Five patients underwent SOC {sup 90}Y bremsstrahlung imaging immediately following routine radioembolization with 3.5 ± 1.7 GBq of {sup 90}Y-labeled glass microspheres. All patients also underwent dPET/CT imaging at 29 ± 11 h following radioembolization. Matched pairs comparison was used to compare image quality, image contrast and {sup 90}Y biodistribution between dPET/CT and bSPECT/CT images. Volumetric assessments of {sup 90}Y activity using different isocontour thresholds on dPET/CT and bSPECT/CT images were also compared. Digital PET/CT consistently provided better visual image quality and {sup 90}Y-to-background image contrast while depicting {sup 90}Y biodistribution than bSPECT/CT. Isocontour volumetric assessment using a 1% threshold precisely outlined {sup 90}Y activity and the treatment volume on dPET/CT images, whereas a more restrictive 20% threshold on bSPECT/CT images was needed to obtain comparable treatment volumes. The use of a less restrictive 10% threshold isocontour on bSPECT/CT images grossly overestimated the treatment volume when compared with the 1% threshold on dPET/CT images. Digital PET/CT is clinically feasible for the assessment of {sup 90}Y microsphere biodistribution following radioembolization, and provides better visual image quality and image contrast than routine bSPECT/CT with comparable acquisition times. With further optimization and clinical validation, dPET technology may allow faster and more accurate imaging-based assessment of {sup 90}Y microsphere biodistribution. (orig.)

  12. PET/MRI of Hepatic 90Y Microsphere Deposition Determines Individual Tumor Response

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, Kathryn J. [Washington University, Department of Radiology (United States); Maughan, Nichole M. [Washington University, Department of Biomedical Engineering (United States); Laforest, Richard [Washington University, Department of Nuclear Medicine (United States); Saad, Nael E. [Washington University, Department of Radiology (United States); Sharma, Akash [Washington University, Department of Nuclear Medicine (United States); Olsen, Jeffrey; Speirs, Christina K.; Parikh, Parag J., E-mail: parikh@wustl.edu [Washington University, Department of Radiation Oncology (United States)

    2016-06-15

    PurposeThe purpose of our study is to determine if there is a relationship between dose deposition measured by PET/MRI and individual lesion response to yttrium-90 ({sup 90}Y) microsphere radioembolization.Materials and Methods26 patients undergoing lobar treatment with {sup 90}Y microspheres underwent PET/MRI within 66 h of treatment and had follow-up imaging available. Adequate visualization of tumor was available in 24 patients, and contours were drawn on simultaneously acquired PET/MRI data. Dose volume histograms (DVHs) were extracted from dose maps, which were generated using a voxelized dose kernel. Similar contours to capture dimensional and volumetric change of tumors were drawn on follow-up imaging. Response was analyzed using both RECIST and volumetric RECIST (vRECIST) criteria.ResultsA total of 8 hepatocellular carcinoma (HCC), 4 neuroendocrine tumor (NET), 9 colorectal metastases (CRC) patients, and 3 patients with other metastatic disease met inclusion criteria. Average dose was useful in predicting response between responders and non-responders for all lesion types and for CRC lesions alone using both response criteria (p < 0.05). D70 (minimum dose to 70 % of volume) was also useful in predicting response when using vRECIST. No significant trend was seen in the other tumor types. For CRC lesions, an average dose of 29.8 Gy offered 76.9 % sensitivity and 75.9 % specificity for response.ConclusionsPET/MRI of {sup 90}Y microsphere distribution showed significantly higher DVH values for responders than non-responders in patients with CRC. DVH analysis of {sup 90}Y microsphere distribution following treatment may be an important predictor of response and could be used to guide future adaptive therapy trials.

  13. PET optimization for improved assessment and accurate quantification of {sup 90}Y-microsphere biodistribution after radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Martí-Climent, Josep M., E-mail: jmmartic@unav.es; Prieto, Elena; Elosúa, César; Rodríguez-Fraile, Macarena; Domínguez-Prado, Inés; Vigil, Carmen; García-Velloso, María J.; Arbizu, Javier; Peñuelas, Iván; Richter, José A. [Nuclear Medicine Department, Clínica Universidad de Navarra, 36, Pío XII Avenue, 31008 Pamplona (Spain)

    2014-09-15

    Purpose: {sup 90}Y-microspheres are widely used for the radioembolization of metastatic liver cancer or hepatocellular carcinoma and there is a growing interest for imaging {sup 90}Y-microspheres with PET. The aim of this study is to evaluate the performance of a current generation PET/CT scanner for {sup 90}Y imaging and to optimize the PET protocol to improve the assessment and the quantification of {sup 90}Y-microsphere biodistribution after radioembolization. Methods: Data were acquired on a Biograph mCT-TrueV scanner with time of flight (TOF) and point spread function (PSF) modeling. Spatial resolution was measured with a{sup 90}Y point source. Sensitivity was evaluated using the NEMA 70 cm line source filled with {sup 90}Y. To evaluate the count rate performance, {sup 90}Y vials with activity ranging from 3.64 to 0.035 GBq were measured in the center of the field of view (CFOV). The energy spectrum was evaluated. Image quality with different reconstructions was studied using the Jaszczak phantom containing six hollow spheres (diameters: 31.3, 28.1, 21.8, 16.1, 13.3, and 10.5 mm), filled with a 207 kBq/ml {sup 90}Y concentration and a 5:1 sphere-to-background ratio. Acquisition time was adjusted to simulate the quality of a realistic clinical PET acquisition of a patient treated with SIR-Spheres{sup ®}. The developed methodology was applied to ten patients after SIR-Spheres{sup ®} treatment acquiring a 10 min per bed PET. Results: The energy spectrum showed the{sup 90}Y bremsstrahlung radiation. The {sup 90}Y transverse resolution, with filtered backprojection reconstruction, was 4.5 mm in the CFOV and degraded to 5.0 mm at 10 cm off-axis. {sup 90}Y absolute sensitivity was 0.40 kcps/MBq in the center of the field of view. Tendency of true and random rates as a function of the {sup 90}Y activity could be accurately described using linear and quadratic models, respectively. Phantom studies demonstrated that, due to low count statistics in {sup 90}Y PET

  14. Y-90 microsphere therapy: prevention of adverse events.

    Science.gov (United States)

    Schultz, Cheryl C; Campbell, Janice; Bakalyar, Donovan; Beauvais, Michele; Feng, Wenzheng; Savin, Michael

    2009-08-01

    Thirty-three (33) events that were inconsistent with intended treatment for 471 Y-90 microsphere deliveries were analyzed from 2001 to 2007. Each occurrence was categorized, based on root-cause analysis, as a device/product defect and/or operator error event. Events were further categorized, if there was an adverse outcome, as spill/leak, termination, recatheterization, dose deviation, and/or a regulatory medical event. Of 264 Y-90 Therasphere (MDS Nordion, Ottawa, Ontario, Canada) treatments, 15 events were reported (5.7%). Of 207 Y-90 SIR-Spheres (Sirtex, Wilmington, MA) treatments, 18 events were reported (8.7%). Twenty-five (25) of 33 events (76%) were device/product defects: 73% for Therasphere (11 of 15) and 78% for SIR-Spheres (14 of 18). There were 31 adverse outcomes associated with 33 events: 15 were leaks and/or spills, 9 resulted in termination of the dose administration, 3 resulted in recatheterization for dose compensation, 2 were dose deviations (doses differing from the prescribed between 10% and 20%), and 2 were reported as regulatory medical events. Fifty-five (55) corrective actions were taken: 39 (71%) were related to the manufacturer and 16 (29%) were hospital based. This process of analyzing each event and measuring our outcomes has been effective at minimizing adverse events and improving patient safety.

  15. Yttrium-90 microspheres (TheraSphere and SIR-Spheres) for the treatment of unresectable hepatocellular carcinoma.

    Science.gov (United States)

    Allison, C

    2007-09-01

    (1) Microspheres containing radioactive yttrium-90 (90Y) are infused into the hepatic artery. These deliver high doses of ionizing radiation to inoperable hepatocellular carcinoma, the most common type of primary liver cancer. (2) Limited evidence from several case series indicates that palliative therapy with 90Y microspheres may reduce tumour size and increase survival time. (3) In some patients, 90Y treatment may result in enough tumour reduction to permit liver resection or transplantation. (4) While 90Y microsphere therapy is generally well tolerated, major complications and several treatment-related deaths have occurred. Improved patient selection criteria and technical changes to microsphere delivery have reduced the risks of complications and death. (5) Patient selection and the technical aspects of 90Y microsphere treatment are complex and require the coordinated expertise of a multidisciplinary team.

  16. Positron-emitting resin microspheres as surrogates of 90Y SIR-Spheres: a radiolabeling and stability study

    International Nuclear Information System (INIS)

    Avila-Rodriguez, Miguel A.; Selwyn, Reed G.; Hampel, Joseph A.; Thomadsen, Bruce R.; DeJesus, Onofre T.; Converse, Alexander K.; Nickles, Robert J.

    2007-01-01

    Commercially available resin microspheres and SIR-Spheres were labeled with metallic positron emitters and evaluated as positron emission tomography (PET) imaging surrogates of 90 Y SIR-Spheres. Radiolabeling was performed using a batch method, and in vitro stability over 24 h was evaluated in saline at physiological pH at 37 o C. The activity per microsphere distribution, as evaluated by autoradiography, showed the activity per microsphere to be proportional to the square radius of the spheres, suggesting surface binding. The in vivo stability of radiolabeling was evaluated in rats by micro-PET imaging after the intravenous injection of labeled microspheres. The different resin microspheres and radionuclides evaluated in this study all showed good radiolabeling efficiency and in vitro stability. However, only resins labeled with 86 Y and 89 Zr proved to have the in vivo stability required for clinical applications

  17. Radiopharmaceutical development based on human blood albumin microspheres and 90Y

    International Nuclear Information System (INIS)

    Petriev, V M; Vlasova, O P; Postnov, A A; Epstein, N B

    2017-01-01

    New radiopharmaceutial (RP) based on human serum albumin microspheres (MSA) and 90 Y was developed for treatment of liver cancer. The optimized synthesis using chelation resulted in approximately 80% yield with high specific activity. The RP developed was tested in mice with inoculated sarcoma-37. In two weeks the tumor size reduced by 43% after the treatment with the dose of 500 μCi injected into the tumor site. (paper)

  18. Sustained safety and efficacy of extended-shelf-life {sup 90}Y glass microspheres: long-term follow-up in a 134-patient cohort

    Energy Technology Data Exchange (ETDEWEB)

    Lewandowski, Robert J.; Minocha, Jeet; Memon, Khairuddin; Riaz, Ahsun; Gates, Vanessa L.; Ryu, Robert K.; Sato, Kent T.; Omary, Reed; Salem, Riad [Northwestern University, Department of Radiology, Chicago, IL (United States)

    2014-03-15

    To validate our initial pilot study and confirm sustained safety and tumor response of extended-shelf-life {sup 90}Y glass microspheres. We hypothesized that for the same planned tissue dose, the increase in number of glass microspheres (decayed to the second week of their allowable shelf-life) administered for the same absorbed dose would result in better tumor distribution of the microspheres without causing additional adverse events. Between June 2007 and January 2010, 134 patients underwent radioembolization with extended-shelf-life {sup 90}Y glass microspheres; data from 84 new patients were combined with data from our 50-patient pilot study cohort. Baseline and follow-up imaging and laboratory data were obtained 1 and 3 months after therapy and every 3 months thereafter. Clinical and biochemical toxicities were prospectively captured and categorized according to the Common Terminology Criteria. Response in the index lesion was assessed using WHO and EASL guidelines. The mean delivered radiation dose was 123 Gy to the target liver tissue. The mean increase in number of microspheres with this approach compared to standard {sup 90}Y glass microsphere dosimetry was 103 %, corresponding to an increase from 3.84 to 7.78 million microspheres. Clinical toxicities included fatigue (89 patients, 66 %), abdominal pain (49 patients, 36.6 %), and nausea/vomiting (25 patients, 18.7 %). Grade 3/4 bilirubin toxicity was seen in three patients (2 %). Two (1 %) of the initial 50-patient cohort showed gastroduodenal ulcers; gastroduodenal ulcers were not seen in any of the subsequent 84 patients. According to WHO and EASL guidelines, response rates were 48 % and 57 %, respectively, and 21 % demonstrated a complete EASL response. This study showed sustained safety and efficacy of extended-shelf-life {sup 90}Y glass microspheres in a larger, 134-patient cohort. The increase in number of microspheres administered theoretically resulted in better tumor distribution of the

  19. Yttrium-90 microsphere induced gastrointestinal tract ulceration

    Directory of Open Access Journals (Sweden)

    Rikabi Ali A

    2008-09-01

    Full Text Available Abstract Background Radiomicrosphere therapy (RT utilizing yttrium-90 (90Y microspheres has been shown to be an effective regional treatment for primary and secondary hepatic malignancies. We sought to determine a large academic institution's experience regarding the extent and frequency of gastrointestinal complications. Methods Between 2004 and 2007, 27 patients underwent RT for primary or secondary hepatic malignancies. Charts were subsequently reviewed to determine the incidence and severity of GI ulceration. Results Three patients presented with gastrointestinal bleeding and underwent upper endoscopy. Review of the pretreatment angiograms showed normal vascular anatomy in one patient, sclerosed hepatic vasculature in a patient who had undergone prior chemoembolization in a second, and an aberrant left hepatic artery in a third. None had undergone prophylactic gastroduodenal artery embolization. Endoscopic findings included erythema, mucosal erosions, and large gastric ulcers. Microspheres were visible on endoscopic biopsy. In two patients, gastric ulcers were persistent at the time of repeat endoscopy 1–4 months later despite proton pump inhibitor therapy. One elderly patient who refused surgical intervention died from recurrent hemorrhage. Conclusion Gastrointestinal ulceration is a known yet rarely reported complication of 90Y microsphere embolization with potentially life-threatening consequences. Once diagnosed, refractory ulcers should be considered for aggressive surgical management.

  20. Therapy with 90Y microspheres: radiation protection in new medical therapies

    International Nuclear Information System (INIS)

    Rojo, Ana; Puerta, Nancy

    2013-01-01

    Primary liver cancer is one of the most frequent in the world and with a low cure rate. Radioembolization using 90y spheres is a promising treatment of this pathology and involves the percutaneous vascular application of radioisotope-labeled the order of Micron size particles. The advantages of this technique include the permit administered high doses of radiation to small volumes with low relative toxicity, offer the possibility of treating all the liver including microscopic tumors, and finally, the feasibility of combined with other therapies. Radiation protection in new medical therapies requires justification and optimization, as requirements for their implementation. The application of the principle of optimization in the context of the protection of the patient must be the minimum that it can be reasonably reached compatible with the required doses of treatment dose to healthy tissue. With 90 Y microspheres therapy this optimization applies to the activity of 90y which is administered to the patient, and estimation methods are postulated. in this work are analyzed comparatively these methods, described the early physicists, equations and the limitations of each. Finally, it is concluded that the optimal method to be implemented for the evaluation of the activity of 90 Y manage must be based in a voxel dosimetric model specific for each patient, however, the partitional method may be a good alternative if you don't have the tools to apply the method

  1. Intra-arterial treatment with 90Y microspheres for hepatocellular carcinoma: 4 years experience at the Ghent University Hospital

    International Nuclear Information System (INIS)

    Lambert, Bieke; Mertens, Jeroen; Oltenfreiter, Ruth; Sturm, Emiel; Defreyne, Luc; Smeets, Peter; Troisi, Roberto; Vlierberghe, Hans van

    2011-01-01

    We report on our experience in terms of eligibility, safety, response and survival for treatment of hepatocellular carcinoma (HCC) with 90 Y microspheres. Secondly, we investigated the urinary excretion of 90 Y following treatment. We retrospectively reviewed all HCC patients referred to our department for 90 Y microsphere treatment. We recorded reasons for not proceeding to actual treatment. In case treatment was performed, we assessed the tolerance (Common Terminology Criteria for Adverse Events v3.0, CTCAE v3.0), the response [modified Response Evaluation Criteria in Solid Tumors (mRECIST) criteria] and long-term survival (Kaplan-Meier). The urinary excretion was estimated by 12-h urine collections post-injection for analysis in a gamma counter. Forty-three HCC patients were referred for radioembolization. Fourteen patients were excluded, mainly due to unfavourable 99m Tc-macroaggregated albumin (MAA) distribution. Twenty-nine patients were treated with 90 Y microspheres (TheraSphere, mean activity 2.17 GBq). In four patients severe clinical adverse events were encountered, however only in one case clearly related to the therapy. Twenty patients were assessable by mRECIST: complete response in 15%, partial response in 35%, stable disease in 30% and progression in 20% were observed. A median survival of 12.3 months (95% confidence interval 9.4-15.2) was estimated. Concerning the substudy on urinary excretion, only 0.0025% of the administered activity was excreted in the urine within the first 12 h following TheraSphere. Following a strict workup before admitting patients to radioembolization with TheraSphere, we found good clinical tolerance in the vast majority of patients. Radiological response assessment yielded an overall response rate of 50%, when evaluated early following treatment. Urine analysis showed consistently only low activities of 90 Y excreted in the urine. (orig.)

  2. Intra-arterial treatment with {sup 90}Y microspheres for hepatocellular carcinoma: 4 years experience at the Ghent University Hospital

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, Bieke; Mertens, Jeroen; Oltenfreiter, Ruth [Ghent University Hospital, Department of Nuclear Medicine, Ghent (Belgium); Sturm, Emiel; Defreyne, Luc [Ghent University Hospital, Department of Vascular and Interventional Radiology, Ghent (Belgium); Smeets, Peter [Ghent University Hospital, Department of Radiology, Ghent (Belgium); Troisi, Roberto [Ghent University Hospital, Department of Hepatobiliary Surgery and Liver Transplantation, Ghent (Belgium); Vlierberghe, Hans van [Ghent University Hospital, Department of Gastroenterology and Hepatology, Ghent (Belgium)

    2011-12-15

    We report on our experience in terms of eligibility, safety, response and survival for treatment of hepatocellular carcinoma (HCC) with {sup 90}Y microspheres. Secondly, we investigated the urinary excretion of {sup 90}Y following treatment. We retrospectively reviewed all HCC patients referred to our department for {sup 90}Y microsphere treatment. We recorded reasons for not proceeding to actual treatment. In case treatment was performed, we assessed the tolerance (Common Terminology Criteria for Adverse Events v3.0, CTCAE v3.0), the response [modified Response Evaluation Criteria in Solid Tumors (mRECIST) criteria] and long-term survival (Kaplan-Meier). The urinary excretion was estimated by 12-h urine collections post-injection for analysis in a gamma counter. Forty-three HCC patients were referred for radioembolization. Fourteen patients were excluded, mainly due to unfavourable {sup 99m}Tc-macroaggregated albumin (MAA) distribution. Twenty-nine patients were treated with {sup 90}Y microspheres (TheraSphere, mean activity 2.17 GBq). In four patients severe clinical adverse events were encountered, however only in one case clearly related to the therapy. Twenty patients were assessable by mRECIST: complete response in 15%, partial response in 35%, stable disease in 30% and progression in 20% were observed. A median survival of 12.3 months (95% confidence interval 9.4-15.2) was estimated. Concerning the substudy on urinary excretion, only 0.0025% of the administered activity was excreted in the urine within the first 12 h following TheraSphere. Following a strict workup before admitting patients to radioembolization with TheraSphere, we found good clinical tolerance in the vast majority of patients. Radiological response assessment yielded an overall response rate of 50%, when evaluated early following treatment. Urine analysis showed consistently only low activities of {sup 90}Y excreted in the urine. (orig.)

  3. Yttrium-90 Selective Internal Radiation Therapy with Glass Microspheres for Hepatocellular Carcinoma: Current and Updated Literature Review

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Edward Wolfgang; Alanis, Lourdes [Division of Interventional Radiology, Department of Radiology, UCLA Medical Center, David Geffen School of Medicine at UCLA, Los Angeles, CA 90095 (United States); Cho, Sung-Ki [Division of Interventional Radiology, Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351 (Korea, Republic of); Saab, Sammy [Division of Hepatology, Department of Medicine, Pfleger Liver Institute, University of California at Los Angeles, Los Angeles, CA 90024 (United States)

    2016-11-01

    Hepatocellular carcinoma is the most common primary liver cancer and it represents the majority of cancer-related deaths in the world. More than 70% of patients present at an advanced stage, beyond potentially curative options. Ytrrium-90 selective internal radiation therapy (Y90-SIRT) with glass microspheres is rapidly gaining acceptance as a potential therapy for intermediate and advanced stage primary hepatocellular carcinoma and liver metastases. The technique involves delivery of Y90 infused glass microspheres via the hepatic arterial blood flow to the appropriate tumor. The liver tumor receives a highly concentrated radiation dose while sparing the healthy liver parenchyma due to its preferential blood supply from portal venous blood. There are two commercially available devices: TheraSphere® and SIR-Spheres®. Although, Y90-SIRT with glass microspheres improves median survival in patients with intermediate and advanced hepatocellular carcinoma and has the potential to downstage hepatocellular carcinoma so that the selected candidates meet the transplantable criteria, it has not gained widespread acceptance due to the lack of large randomized controlled trials. Currently, there are various clinical trials investigating the use of Y90-SIRT with glass microspheres for treatment of hepatocellular carcinoma and the outcomes of these trials may result in the incorporation of Y90-SIRT with glass microspheres into the treatment guidelines as a standard therapy option for patients with intermediate and advanced stage hepatocellular carcinoma.

  4. Yttrium-90 selective internal radiation therapy with glass microspheres for hepatocellular carcinoma: Current and updated literature review

    International Nuclear Information System (INIS)

    Lee, Edward Wolfgang; Alanic, Lourdes; Cho, Sung Ki; Saab, Sammy

    2016-01-01

    Hepatocellular carcinoma is the most common primary liver cancer and it represents the majority of cancer-related deaths in the world. More than 70% of patients present at an advanced stage, beyond potentially curative options. Ytrrium-90 selective internal radiation therapy (Y90-SIRT) with glass microspheres is rapidly gaining acceptance as a potential therapy for intermediate and advanced stage primary hepatocellular carcinoma and liver metastases. The technique involves delivery of Y90 infused glass microspheres via the hepatic arterial blood flow to the appropriate tumor. The liver tumor receives a highly concentrated radiation dose while sparing the healthy liver parenchyma due to its preferential blood supply from portal venous blood. There are two commercially available devices: TheraSphere® and SIR-Spheres®. Although, Y90-SIRT with glass microspheres improves median survival in patients with intermediate and advanced hepatocellular carcinoma and has the potential to downstage hepatocellular carcinoma so that the selected candidates meet the transplantable criteria, it has not gained widespread acceptance due to the lack of large randomized controlled trials. Currently, there are various clinical trials investigating the use of Y90-SIRT with glass microspheres for treatment of hepatocellular carcinoma and the outcomes of these trials may result in the incorporation of Y90-SIRT with glass microspheres into the treatment guidelines as a standard therapy option for patients with intermediate and advanced stage hepatocellular carcinoma

  5. Yttrium-90 Selective Internal Radiation Therapy with Glass Microspheres for Hepatocellular Carcinoma: Current and Updated Literature Review

    International Nuclear Information System (INIS)

    Lee, Edward Wolfgang; Alanis, Lourdes; Cho, Sung-Ki; Saab, Sammy

    2016-01-01

    Hepatocellular carcinoma is the most common primary liver cancer and it represents the majority of cancer-related deaths in the world. More than 70% of patients present at an advanced stage, beyond potentially curative options. Ytrrium-90 selective internal radiation therapy (Y90-SIRT) with glass microspheres is rapidly gaining acceptance as a potential therapy for intermediate and advanced stage primary hepatocellular carcinoma and liver metastases. The technique involves delivery of Y90 infused glass microspheres via the hepatic arterial blood flow to the appropriate tumor. The liver tumor receives a highly concentrated radiation dose while sparing the healthy liver parenchyma due to its preferential blood supply from portal venous blood. There are two commercially available devices: TheraSphere® and SIR-Spheres®. Although, Y90-SIRT with glass microspheres improves median survival in patients with intermediate and advanced hepatocellular carcinoma and has the potential to downstage hepatocellular carcinoma so that the selected candidates meet the transplantable criteria, it has not gained widespread acceptance due to the lack of large randomized controlled trials. Currently, there are various clinical trials investigating the use of Y90-SIRT with glass microspheres for treatment of hepatocellular carcinoma and the outcomes of these trials may result in the incorporation of Y90-SIRT with glass microspheres into the treatment guidelines as a standard therapy option for patients with intermediate and advanced stage hepatocellular carcinoma

  6. Yttrium-90 selective internal radiation therapy with glass microspheres for hepatocellular carcinoma: Current and updated literature review

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Edward Wolfgang; Alanic, Lourdes [Div. of Interventional Radiology, Dept. of Radiology, UCLA Medical Center, David Geffen School of Medicine at UCLA, Los Angeles (United States); Cho, Sung Ki [Div. of Interventional Radiology, Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Saab, Sammy [Div. of Hepatology, Dept. of Medicine, Pfleger Liver Institute, University of California at Los Angeles, Los Angeles (United States)

    2016-07-15

    Hepatocellular carcinoma is the most common primary liver cancer and it represents the majority of cancer-related deaths in the world. More than 70% of patients present at an advanced stage, beyond potentially curative options. Ytrrium-90 selective internal radiation therapy (Y90-SIRT) with glass microspheres is rapidly gaining acceptance as a potential therapy for intermediate and advanced stage primary hepatocellular carcinoma and liver metastases. The technique involves delivery of Y90 infused glass microspheres via the hepatic arterial blood flow to the appropriate tumor. The liver tumor receives a highly concentrated radiation dose while sparing the healthy liver parenchyma due to its preferential blood supply from portal venous blood. There are two commercially available devices: TheraSphere® and SIR-Spheres®. Although, Y90-SIRT with glass microspheres improves median survival in patients with intermediate and advanced hepatocellular carcinoma and has the potential to downstage hepatocellular carcinoma so that the selected candidates meet the transplantable criteria, it has not gained widespread acceptance due to the lack of large randomized controlled trials. Currently, there are various clinical trials investigating the use of Y90-SIRT with glass microspheres for treatment of hepatocellular carcinoma and the outcomes of these trials may result in the incorporation of Y90-SIRT with glass microspheres into the treatment guidelines as a standard therapy option for patients with intermediate and advanced stage hepatocellular carcinoma.

  7. Yttrium-90 Selective Internal Radiation Therapy with Glass Microspheres for Hepatocellular Carcinoma: Current and Updated Literature Review.

    Science.gov (United States)

    Lee, Edward Wolfgang; Alanis, Lourdes; Cho, Sung-Ki; Saab, Sammy

    2016-01-01

    Hepatocellular carcinoma is the most common primary liver cancer and it represents the majority of cancer-related deaths in the world. More than 70% of patients present at an advanced stage, beyond potentially curative options. Ytrrium-90 selective internal radiation therapy (Y90-SIRT) with glass microspheres is rapidly gaining acceptance as a potential therapy for intermediate and advanced stage primary hepatocellular carcinoma and liver metastases. The technique involves delivery of Y90 infused glass microspheres via the hepatic arterial blood flow to the appropriate tumor. The liver tumor receives a highly concentrated radiation dose while sparing the healthy liver parenchyma due to its preferential blood supply from portal venous blood. There are two commercially available devices: TheraSphere® and SIR-Spheres®. Although, Y90-SIRT with glass microspheres improves median survival in patients with intermediate and advanced hepatocellular carcinoma and has the potential to downstage hepatocellular carcinoma so that the selected candidates meet the transplantable criteria, it has not gained widespread acceptance due to the lack of large randomized controlled trials. Currently, there are various clinical trials investigating the use of Y90-SIRT with glass microspheres for treatment of hepatocellular carcinoma and the outcomes of these trials may result in the incorporation of Y90-SIRT with glass microspheres into the treatment guidelines as a standard therapy option for patients with intermediate and advanced stage hepatocellular carcinoma.

  8. Yttrium 90 microspheres for the treatment of hepatocellular carcinoma.

    Science.gov (United States)

    Memon, Khairuddin; Lewandowski, Robert J; Riaz, Ahsun; Salem, Riad

    2013-01-01

    Yttrium-90 microspheres are radioactive particles which are increasingly being employed for treating patients with unresectable hepatocellular carcinoma (HCC). The procedure is called radioembolization. It involves the injection of micron-sized embolic particles loaded with a radioisotope by use of transarterial techniques. Because of the sensitivity of liver parenchyma and relative insensitivity of tumor, external radiation has played a limited role in treating HCC. (90)Y administered via arterial route directs the highly concentrated radiation to the tumor while healthy liver parenchyma is relatively spared due to its preferential blood supply from portal venous blood. This technique has proven useful for the majority of patients with HCC as most of them present in advanced stage, beyond potentially curative options (resection/liver transplantation). (90)Y microspheres can be used in downstaging large tumors to bring within transplantable criteria, in patients with portal venous thrombosis due to tumor invasion and as palliative therapy. There are two available devices for (90)Y administration; TheraSphere® (glass based) and SIR-Spheres® (resin based). The procedure is performed on an outpatient basis. The incidence of complications is comparatively less and may include nausea, fatigue, abdominal pain, hepatic dysfunction, biliary injury, fibrosis, radiation pneumonitis, GI ulcers, and vascular injury; however, these can be avoided by meticulous pretreatment assessment, careful patient selection, and adequate dosimetry. This article explores the technical and clinical aspects of (90)Y radioembolization with keeping emphasis on patient selection, uses, and complications.

  9. Yttrium-90 resin microspheres and their use in the treatment of intrahepatic cholangiocarcinoma.

    Science.gov (United States)

    Filippi, Luca; Schillaci, Orazio; Cianni, Roberto; Bagni, Oreste

    2018-04-01

    Intrahepatic cholangiocarcinoma (ICC) is a severe and rapidly progressive hepatic tumor. Surgery is often impracticable due to locally advanced presentation. On the other hand, chemotherapy has demonstrated only limited effectiveness. For these reasons, liver-directed therapies have been successfully applied for treating ICC. In particular, radioembolization with Yttrium-90 ( 90 Y)-labeled spheres has been reported to be a promising therapeutic approach for this neoplasia. Two commercial forms of 90 Y-labeled spheres are available: glass (TheraSphere ® ) and resin (SIR-Spheres ® ) microspheres. The aim of the present paper is to review the existing literature on the use of the resin microspheres for the treatment of unresectable and chemorefractory ICC, focusing on the methodology, clinical applications and side effects.

  10. Personnel dose reduction in 90Y microspheres liver-directed radioembolization: from interventional radiology suite to patient ward.

    Science.gov (United States)

    Law, Martin; Wong, K K; Tso, W K; Lee, Victor; Luk, M Y; Tong, C C; Chu, Ferdinand

    2017-03-01

    To describe a method to reduce the external radiation exposure emitted from the patient after liver-directed radioembolization using 90 Y glass microspheres, to quantitatively estimate the occupational dose of medical personnel providing patient care to the patient radioembolized with the use of the method and to discuss radiation exposure to patients who are adjacent if the patient radioembolized needs hospitalization. A lead-lined blanket of lead equivalence of 0.5 mm was used to cover the patient abdomen immediately after the 90 Y radioembolization procedure, in order to reduce the radiation emitted from the patient. The interventional radiologist used a rod-type puncture site compressor for haemostasis to avoid direct contact with possible residual radioactivity at the puncture site. Dose rates were measured at the interventional radiologist chest and hand positions during puncture site pressing for haemostasis with and without the use of the blanket. The measurement results were applied to estimate the occupational dose of colleagues performing patient care to the patient radioembolized. The exposure to patients adjacent in the ward was estimated if the patient radioembolized was hospitalized. The radiation exposures measured at the radiologist chest and hand positions have been significantly reduced with the lead-lined blanket in place. The radiologist, performing puncture site pressing at the end of radioembolization procedure, would receive an average hand dose of 1.95 μSv and body dose under his own lead apron of 0.30 μSv for an average 90 Y microsphere radioactivity of 2.54 GBq. Other medical personnel, nurses and porters, would receive occupational doses corresponding to an hour of background radiation. If the patient radioembolized using 90 Y needs hospitalization in a common ward, using the lead-lined blanket to cover the abdomen of the patient and keeping a distance of 2 m from the patient who is adjacent would reduce the exposure by 0

  11. Therapy with {sup 90}Y microspheres: radiation protection in new medical therapies; Terapia con microesferas de {sup 90}Y: proteccion radiologica en nuevas terapias medicas

    Energy Technology Data Exchange (ETDEWEB)

    Rojo, Ana; Puerta, Nancy, E-mail: arojo@arn.gob.ar [Autoridad Regulatoria Nuclear (ARN), Buenos Aires (Argentina)

    2013-07-01

    Primary liver cancer is one of the most frequent in the world and with a low cure rate. Radioembolization using 90y spheres is a promising treatment of this pathology and involves the percutaneous vascular application of radioisotope-labeled the order of Micron size particles. The advantages of this technique include the permit administered high doses of radiation to small volumes with low relative toxicity, offer the possibility of treating all the liver including microscopic tumors, and finally, the feasibility of combined with other therapies. Radiation protection in new medical therapies requires justification and optimization, as requirements for their implementation. The application of the principle of optimization in the context of the protection of the patient must be the minimum that it can be reasonably reached compatible with the required doses of treatment dose to healthy tissue. With {sup 90}Y microspheres therapy this optimization applies to the activity of 90y which is administered to the patient, and estimation methods are postulated. in this work are analyzed comparatively these methods, described the early physicists, equations and the limitations of each. Finally, it is concluded that the optimal method to be implemented for the evaluation of the activity of {sup 90}Y manage must be based in a voxel dosimetric model specific for each patient, however, the partitional method may be a good alternative if you don't have the tools to apply the method.

  12. Process improvement for the safe delivery of multidisciplinary-executed treatments-A case in Y-90 microspheres therapy.

    Science.gov (United States)

    Cai, Bin; Altman, Michael B; Garcia-Ramirez, Jose; LaBrash, Jason; Goddu, S Murty; Mutic, Sasa; Parikh, Parag J; Olsen, Jeffrey R; Saad, Nael; Zoberi, Jacqueline E

    To develop a safe and robust workflow for yttrium-90 (Y-90) radioembolization procedures in a multidisciplinary team environment. A generalized Define-Measure-Analyze-Improve-Control (DMAIC)-based approach to process improvement was applied to a Y-90 radioembolization workflow. In the first DMAIC cycle, events with the Y-90 workflow were defined and analyzed. To improve the workflow, a web-based interactive electronic white board (EWB) system was adopted as the central communication platform and information processing hub. The EWB-based Y-90 workflow then underwent a second DMAIC cycle. Out of 245 treatments, three misses that went undetected until treatment initiation were recorded over a period of 21 months, and root-cause-analysis was performed to determine causes of each incident and opportunities for improvement. The EWB-based Y-90 process was further improved via new rules to define reliable sources of information as inputs into the planning process, as well as new check points to ensure this information was communicated correctly throughout the process flow. After implementation of the revised EWB-based Y-90 workflow, after two DMAIC-like cycles, there were zero misses out of 153 patient treatments in 1 year. The DMAIC-based approach adopted here allowed the iterative development of a robust workflow to achieve an adaptable, event-minimizing planning process despite a complex setting which requires the participation of multiple teams for Y-90 microspheres therapy. Implementation of such a workflow using the EWB or similar platform with a DMAIC-based process improvement approach could be expanded to other treatment procedures, especially those requiring multidisciplinary management. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  13. Model-Based Radiation Dose Correction for Yttrium-90 Microsphere Treatment of Liver Tumors With Central Necrosis

    International Nuclear Information System (INIS)

    Liu, Ching-Sheng; Lin, Ko-Han; Lee, Rheun-Chuan; Tseng, Hsiou-Shan; Wang, Ling-Wei; Huang, Pin-I; Chao, Liung-Sheau; Chang, Cheng-Yen; Yen, Sang-Hue; Tung, Chuan-Jong; Wang, Syh-Jen; Oliver Wong, Ching-yee; Liu, Ren-Shyan

    2011-01-01

    Purpose: The objectives of this study were to model and calculate the absorbed fraction φ of energy emitted from yttrium-90 ( 90 Y) microsphere treatment of necrotic liver tumors. Methods and Materials: The tumor necrosis model was proposed for the calculation of φ over the spherical shell region. Two approaches, the semianalytic method and the probabilistic method, were adopted. In the former method, the range--energy relationship and the sampling of electron paths were applied to calculate the energy deposition within the target region, using the straight-ahead and continuous-slowing-down approximation (CSDA) method. In the latter method, the Monte Carlo PENELOPE code was used to verify results from the first method. Results: The fraction of energy, φ, absorbed from 90 Y by 1-cm thickness of tumor shell from microsphere distribution by CSDA with complete beta spectrum was 0.832 ± 0.001 and 0.833 ± 0.001 for smaller (r T = 5 cm) and larger (r T = 10 cm) tumors (where r is the radii of the tumor [T] and necrosis [N]). The fraction absorbed depended mainly on the thickness of the tumor necrosis configuration, rather than on tumor necrosis size. The maximal absorbed fraction φ that occurred in tumors without central necrosis for each size of tumor was different: 0.950 ± 0.000, and 0.975 ± 0.000 for smaller (r T = 5 cm) and larger (r T = 10 cm) tumors, respectively (p 90 Y microsphere treatment of hepatic tumors with central necrosis. With this model, important information is provided regarding the absorbed fraction applicable to clinical 90 Y microsphere treatment.

  14. 90Sr content in 90Y-labeled SIR-spheres and Zevalin.

    Science.gov (United States)

    Metyko, John; Erwin, William; Poston, John; Jimenez, Sandra

    2014-11-01

    Three different 90Y internally administered radionuclide therapies are currently used in both standard-of-care and clinical trial procedures atMD Anderson Cancer Center. TheraSphere and SIR-Spheres therapies utilize 90Y-labeled microspheres, while Zevalin is an 90Y-labeled radioimmunotherapeutic agent. Several publications have indicated radionuclidic impurities resulting from 90Y production methods. The 90Y in SIR-Spheres and Zevalin are produced from a 90Sr/90Y generator, which leaves measurable quantities of 90Sr in the final product. TheraSphere 90Y is produced in a nuclear reactor which results in a large number of impurities, most notably 88Y and 91Y. Product information sheets reference these impurities with specific limits given. These limits represent a tiny fraction of the total product activity, and in the case of TheraSphere and SIR-Spheres gamma-emitting impurities, this has been verified in the literature. An analysis of 90Sr impurities in SIR-Spheres and Zevalin is presented in this paper. Impurity quantities were found to be within the vendors’ documented limits.

  15. Treatment of unresectable hepatocellular carcinoma with use of 90Y microspheres (TheraSphere): safety, tumor response, and survival.

    Science.gov (United States)

    Salem, Riad; Lewandowski, Robert J; Atassi, Bassel; Gordon, Stuart C; Gates, Vanessa L; Barakat, Omar; Sergie, Ziad; Wong, Ching-Yee O; Thurston, Kenneth G

    2005-12-01

    To present safety and efficacy results obtained in treatment of a cohort of patients with unresectable hepatocellular carcinoma (HCC) with use of 90Y microspheres (TheraSphere). Forty-three consecutive patients with HCC were treated with 90Y microspheres over a 4-year period. Patients were treated by liver segment or lobe on one or more occasions based on tumor distribution, liver function, and vascular flow dynamics. Patients were followed for adverse events, objective tumor response, and survival. Patients were stratified into three risk groups according to method of treatment and risk stratification (group 0, segmental; group 1, lobar low-risk; group 2, lobar high-risk) and Okuda and Child-Pugh scoring systems. Based on follow-up data from 43 treated patients, 20 patients (47%) had an objective tumor response based on percent reduction in tumor size and 34 patients (79%) had a tumor response when percent reduction and/or tumor necrosis were used as a composite measure of tumor response. There was no statistical difference among the three risk groups with respect to tumor response. Survival times from date of diagnosis were different among the risk groups (P TheraSpheres) provides a safe and effective method of treatment for a broad spectrum of patients presenting with unresectable HCC. Further investigation is warranted.

  16. Effects of hepatic arterial yttrium 90 glass microspheres in dogs.

    Science.gov (United States)

    Wollner, I; Knutsen, C; Smith, P; Prieskorn, D; Chrisp, C; Andrews, J; Juni, J; Warber, S; Klevering, J; Crudup, J

    1988-04-01

    A 22-micron glass microsphere called TheraSphere (Theragenics Corp., Atlanta, GA) has been developed in which yttrium 89 oxide is incorporated into the glass matrix and is activated by neutron bombardment to form the beta-emitting isotope yttrium 90 (Y 90) before using the spheres as radiotherapeutic vehicles. The injection of up to 12 times (on a liver weight basis) the anticipated human dose of nonradioactive TheraSphere into the hepatic arteries of dogs was well tolerated and produced clinically silent alterations within centrolobular areas. The hepatic arterial (HA) injection of radioactive TheraSphere also produced portal changes similar to those observed in humans after external beam therapy. While the extent of damage increased with the delivered dose, radiation exposures in excess of 30,000 cGy did not cause total hepatic necrosis and were compatible with survival. No microspheres distributed to the bone marrow and absolutely no myelosuppression was encountered in any animal. Proposed hepatic exposures to humans of 5000 to 10,000 cGy by means of these microspheres, therefore, would appear to be feasible and tolerable. Radiotherapeutic microsphere administration preceded by regional infusion of a radiosensitizing agent and/or immediately following the redistribution of blood flow toward intrahepatic tumor by vasoactive agents can potentially yield a synergistic, highly selective attack on tumors confined to the liver.

  17. Radioembolization using 90Y-resin microspheres for patients with advanced hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Sangro, Bruno; Bilbao, Jose I.; Boan, Jose; Martinez-Cuesta, Antonio; Benito, Alberto; Rodriguez, Javier; Panizo, Angel; Gil, Belen; Inarrairaegui, Mercedes; Herrero, Ignacio; Quiroga, Jorge; Prieto, Jesus

    2006-01-01

    Purpose: To investigate the antitumor effect of resin microspheres loaded with 90-yttrium against hepatocellular carcinoma and their safety in the setting of liver cirrhosis. Patients and Methods: Data from 24 consecutive patients with hepatocellular carcinoma (HCC) treated by radioembolization in the period from September 2003 to February 2005 were reviewed. Patients received no further antineoplastic therapy. A comprehensive evaluation was performed to prevent the risk of damage due to microsphere misplacing. Patients were discharged the day after microspheres injection. Results: Serious liver toxicity observed among cirrhotic patients in a first period was subsequently prevented by modifying the selection criteria and the method for calculating the activity to be administered. Among 21 patients evaluable for response using Response Evaluation Criteria in Solid Tumors (RECIST) criteria, a reduction in size of target lesions was observed in all but 1 patient. When considering only target lesions, disease control rate and response rate were 100% and 23.8%, respectively. However, 43% of patients progressed in the liver in the form of new lesions appearing a median time of 3 months after radioembolization. Conclusion: Our experience in these series of patients indicates that radioembolization using resin microspheres has a significant antitumor effect against HCC and that using stringent selection criteria and conservative models for calculating Radiation activity to be administered, radioembolization can be performed safely even in cirrhotic patients

  18. 3D inpatient dose reconstruction from the PET-CT imaging of 90Y microspheres for metastatic cancer to the liver: feasibility study.

    Science.gov (United States)

    Fourkal, E; Veltchev, I; Lin, M; Koren, S; Meyer, J; Doss, M; Yu, J Q

    2013-08-01

    The introduction of radioembolization with microspheres represents a significant step forward in the treatment of patients with metastatic disease to the liver. This technique uses semiempirical formulae based on body surface area or liver and target volumes to calculate the required total activity for a given patient. However, this treatment modality lacks extremely important information, which is the three-dimensional (3D) dose delivered by microspheres to different organs after their administration. The absence of this information dramatically limits the clinical efficacy of this modality, specifically the predictive power of the treatment. Therefore, the aim of this study is to develop a 3D dose calculation technique that is based on the PET imaging of the infused microspheres. The Fluka Monte Carlo code was used to calculate the voxel dose kernel for 90Y source with voxel size equal to that of the PET scan. The measured PET activity distribution was converted to total activity distribution for the subsequent convolution with the voxel dose kernel to obtain the 3D dose distribution. In addition, dose-volume histograms were generated to analyze the dose to the tumor and critical structures. The 3D inpatient dose distribution can be reconstructed from the PET data of a patient scanned after the infusion of microspheres. A total of seven patients have been analyzed so far using the proposed reconstruction method. Four patients underwent treatment with SIR-Spheres for liver metastases from colorectal cancer and three patients were treated with Therasphere for hepatocellular cancer. A total of 14 target tumors were contoured on post-treatment PET-CT scans for dosimetric evaluation. Mean prescription activity was 1.7 GBq (range: 0.58-3.8 GBq). The resulting mean maximum measured dose to targets was 167 Gy (range: 71-311 Gy). Mean minimum dose to 70% of target (D70) was 68 Gy (range: 25-155 Gy). Mean minimum dose to 90% of target (D90) was 53 Gy (range: 13-125 Gy). A

  19. Semi-quantitative analysis of post-transarterial radioembolization 90Y Microsphere position emission tomography combined with computed tomography (PET/CT) images in advance liver malignancy: Comparison with 99mTc macroaggregated albumin (MAA) single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Rhee, Seung Hong; Kim, Sung Eun; Cho, Jae Hyuk; Park, Ju Kyung; Kim, Yun Hwan; Choe, Jae Gol; Eo, Jae Seon; Park, So Yeon; Lee, Eun Sub

    2016-01-01

    The purpose of this study is to evaluate the correlation between pretreatment planning technetium-99m ( 99 mTc) macroaggregated albumin (MAA) SPECT images and posttreatment transarterial radioembolization (TARE) yttirum-90 ( 90 Y) PET/CT images by comparing the ratios of tumor-to-normal liver counts. Fifty-two patients with advanced hepatic malignancy who underwent 90 Y microsphere radioembolization from January 2010 to December 2012 were retrospectively reviewed. Patients had undergone 99 mTc MAA intraarterial injection SPECT for a pretreatment evaluation of microsphere distribution and therapy planning. After the administration of 90 Y microspheres, the patients underwent posttreatment 90 Y PET/CT within 24 h. For semiquantitative analysis, the tumor-to-normal uptake ratios in 90 Y PET/CT (TNR-yp) and 99 mTc MAA SPECT (TNR-ms) as well as the tumor volumes measured in angiographic CT were obtained and analyzed. The relationship of TNR-yp and TNR-ms was evaluated by Spearman's rank correlation and Wilcoxon's matched pairs test. In a total of 79 lesions of 52 patients, the distribution of microspheres was well demonstrated in both the SPECT and PET/CT images. A good correlation was observed of between TNR-ms and TNR-yp (rho value = 0.648, p < 0.001). The TNR-yp (median 2.78, interquartile range 2.43) tend to show significantly higher values than TNR-ms (median 2.49, interquartile range of 1.55) (p = 0.012). The TNR-yp showed weak correlation with tumor volume (rho = 0.230, p = 0.041). The 99mTc MAA SPECT showed a good correlation with 90 Y PET/CT in TNR values, suggesting that 99 mTc MAA can be used as an adequate pretreatment evaluation method. However, the 99 mTc MAA SPECT image consistently shows lower TNR values compared to 90Y PET/CT, which means the possibility of underestimation of tumorous uptake in the partition dosimetry model using 99 mTc MAA SPECT. Considering that 99 mTc MAA is the only clinically available surrogate marker

  20. Yttrium-90 microspheres for the treatment of hepatocellular carcinoma.

    Science.gov (United States)

    Geschwind, Jean Francois H; Salem, Riad; Carr, Brian I; Soulen, Michael C; Thurston, Kenneth G; Goin, Kathleen A; Van Buskirk, Mark; Roberts, Carol A; Goin, James E

    2004-11-01

    Unresectable hepatocellular carcinoma is extremely difficult to treat. TheraSphere consists of yttrium-90 (a pure beta emitter) microspheres, which are injected into the hepatic arteries. This article reviews the safety and survival of patients with hepatocellular carcinoma who were treated with yttrium-90 microspheres. Eighty patients were selected from a database of 108 yttrium-90 microsphere-treated patients and were staged by using Child-Pugh, Okuda, and Cancer of the Liver Italian Program scoring systems. Patients were treated with local, regional, and whole-liver approaches. Survival from first treatment was analyzed with Kaplan-Meier and Cox regression methods. Adverse events and complications of treatment were coded by using the Southwest Oncology Group toxicity scoring system. Patients received liver doses ranging from 47 to 270 Gy. Thirty-two patients (40%) received more than 1 treatment. Survival correlated with pretreatment Cancer of the Liver Italian Program scores ( P = .002), as well as with the individual Cancer of the Liver Italian Program components, Child-Pugh class, alpha-fetoprotein levels, and percentage of tumor replacement. Patients classified as Okuda stage I (n = 54) and II (n = 26) had median survival durations and 1-year survival rates of 628 days and 63%, and 384 days and 51%, respectively ( P = .02). One patient died of liver failure judged as possibly related to treatment. Thus, in selected patients with hepatocellular carcinoma, yttrium-90 microsphere treatment is safe and well tolerated. On the basis of these results, a randomized controlled trial is warranted comparing yttrium-90 microsphere treatment with transarterial chemoembolization by using the Cancer of the Liver Italian Program system for prospective stratified randomization.

  1. 3D inpatient dose reconstruction from the PET-CT imaging of 90Y microspheres for metastatic cancer to the liver: Feasibility study

    International Nuclear Information System (INIS)

    Fourkal, E.; Veltchev, I.; Lin, M.; Meyer, J.; Koren, S.; Doss, M.; Yu, J. Q.

    2013-01-01

    Purpose: The introduction of radioembolization with microspheres represents a significant step forward in the treatment of patients with metastatic disease to the liver. This technique uses semiempirical formulae based on body surface area or liver and target volumes to calculate the required total activity for a given patient. However, this treatment modality lacks extremely important information, which is the three-dimensional (3D) dose delivered by microspheres to different organs after their administration. The absence of this information dramatically limits the clinical efficacy of this modality, specifically the predictive power of the treatment. Therefore, the aim of this study is to develop a 3D dose calculation technique that is based on the PET imaging of the infused microspheres.Methods: The Fluka Monte Carlo code was used to calculate the voxel dose kernel for 90 Y source with voxel size equal to that of the PET scan. The measured PET activity distribution was converted to total activity distribution for the subsequent convolution with the voxel dose kernel to obtain the 3D dose distribution. In addition, dose-volume histograms were generated to analyze the dose to the tumor and critical structures.Results: The 3D inpatient dose distribution can be reconstructed from the PET data of a patient scanned after the infusion of microspheres. A total of seven patients have been analyzed so far using the proposed reconstruction method. Four patients underwent treatment with SIR-Spheres for liver metastases from colorectal cancer and three patients were treated with Therasphere for hepatocellular cancer. A total of 14 target tumors were contoured on post-treatment PET-CT scans for dosimetric evaluation. Mean prescription activity was 1.7 GBq (range: 0.58–3.8 GBq). The resulting mean maximum measured dose to targets was 167 Gy (range: 71–311 Gy). Mean minimum dose to 70% of target (D70) was 68 Gy (range: 25–155 Gy). Mean minimum dose to 90% of target (D90

  2. Radioactive impurities in radiopharmaceuticals with Y-90. Consequences for waste disposal; Radioaktive Verunreinigungen in Radiopharmazeutika mit Y-90. Konsequenzen fuer die Entsorgung von Reststoffen

    Energy Technology Data Exchange (ETDEWEB)

    Wanke, C.; Solle, A.; Geworski, L. [Medizinische Hochschule Hannover (Germany). Stabsstelle Strahlenschutz und Abt. Medizinische Physik

    2016-07-01

    Y-90 plays an important role in nuclear medicine and is of particular interest in radiation synovectomy (RSO) and in Selective internal radiation therapy (SIRT). Longer-lived impurities were investigated in a pharmaceutical used in RSO and in glass microspheres applied for SIRT. For this, measurements were carried out to identify gamma-emitting impurities. Especially in the late measurements, after decay of Y-90, impurities such as Y-88 and Y-91, Zn-65, Eu-152, Gd-153, Tb-160 und Yb-169 were identified, which accounted for less than 0,01 % of the total radioactivity at the calibration date, so that all pharmaceutical requirements were met. The impurities, however, have to be taken into account in waste management and clearance. Assuming typical masses, waste from RSO can undergo unrestricted clearance based on the clearance values tabulated in the German Radiation Protection Ordinance, provided sufficient decay storage. For waste from SIRT with glass microspheres, however, other clearance or disposal options have to be found.

  3. 3D inpatient dose reconstruction from the PET-CT imaging of {sup 90}Y microspheres for metastatic cancer to the liver: Feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Fourkal, E.; Veltchev, I.; Lin, M.; Meyer, J. [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111 (United States); Koren, S. [Department of Radiation Oncology, Beth Israel Comprehensive Cancer Center, New York, New York 10011 (United States); Doss, M.; Yu, J. Q. [Department of Diagnostic Imaging, Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111 (United States)

    2013-08-15

    Purpose: The introduction of radioembolization with microspheres represents a significant step forward in the treatment of patients with metastatic disease to the liver. This technique uses semiempirical formulae based on body surface area or liver and target volumes to calculate the required total activity for a given patient. However, this treatment modality lacks extremely important information, which is the three-dimensional (3D) dose delivered by microspheres to different organs after their administration. The absence of this information dramatically limits the clinical efficacy of this modality, specifically the predictive power of the treatment. Therefore, the aim of this study is to develop a 3D dose calculation technique that is based on the PET imaging of the infused microspheres.Methods: The Fluka Monte Carlo code was used to calculate the voxel dose kernel for {sup 90}Y source with voxel size equal to that of the PET scan. The measured PET activity distribution was converted to total activity distribution for the subsequent convolution with the voxel dose kernel to obtain the 3D dose distribution. In addition, dose-volume histograms were generated to analyze the dose to the tumor and critical structures.Results: The 3D inpatient dose distribution can be reconstructed from the PET data of a patient scanned after the infusion of microspheres. A total of seven patients have been analyzed so far using the proposed reconstruction method. Four patients underwent treatment with SIR-Spheres for liver metastases from colorectal cancer and three patients were treated with Therasphere for hepatocellular cancer. A total of 14 target tumors were contoured on post-treatment PET-CT scans for dosimetric evaluation. Mean prescription activity was 1.7 GBq (range: 0.58–3.8 GBq). The resulting mean maximum measured dose to targets was 167 Gy (range: 71–311 Gy). Mean minimum dose to 70% of target (D70) was 68 Gy (range: 25–155 Gy). Mean minimum dose to 90% of target

  4. Semi-quantitative analysis of post-transarterial radioembolization {sup 90}Y Microsphere position emission tomography combined with computed tomography (PET/CT) images in advance liver malignancy: Comparison with {sup 99m}Tc macroaggregated albumin (MAA) single photon emission computed tomography (SPECT)

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, Seung Hong; Kim, Sung Eun; Cho, Jae Hyuk; Park, Ju Kyung; Kim, Yun Hwan; Choe, Jae Gol [Korea University Anam Hospital, Seoul (Korea, Republic of); Eo, Jae Seon; Park, So Yeon; Lee, Eun Sub [Dept. of Nuclear Medicine, Korea University Guro Hospital, Seoul (Korea, Republic of)

    2016-03-15

    The purpose of this study is to evaluate the correlation between pretreatment planning technetium-99m ({sup 99}mTc) macroaggregated albumin (MAA) SPECT images and posttreatment transarterial radioembolization (TARE) yttirum-90 ({sup 90}Y) PET/CT images by comparing the ratios of tumor-to-normal liver counts. Fifty-two patients with advanced hepatic malignancy who underwent {sup 90}Y microsphere radioembolization from January 2010 to December 2012 were retrospectively reviewed. Patients had undergone {sup 99}mTc MAA intraarterial injection SPECT for a pretreatment evaluation of microsphere distribution and therapy planning. After the administration of {sup 90}Y microspheres, the patients underwent posttreatment {sup 90}Y PET/CT within 24 h. For semiquantitative analysis, the tumor-to-normal uptake ratios in {sup 90}Y PET/CT (TNR-yp) and {sup 99}mTc MAA SPECT (TNR-ms) as well as the tumor volumes measured in angiographic CT were obtained and analyzed. The relationship of TNR-yp and TNR-ms was evaluated by Spearman's rank correlation and Wilcoxon's matched pairs test. In a total of 79 lesions of 52 patients, the distribution of microspheres was well demonstrated in both the SPECT and PET/CT images. A good correlation was observed of between TNR-ms and TNR-yp (rho value = 0.648, p < 0.001). The TNR-yp (median 2.78, interquartile range 2.43) tend to show significantly higher values than TNR-ms (median 2.49, interquartile range of 1.55) (p = 0.012). The TNR-yp showed weak correlation with tumor volume (rho = 0.230, p = 0.041). The 99mTc MAA SPECT showed a good correlation with {sup 90}Y PET/CT in TNR values, suggesting that {sup 99}mTc MAA can be used as an adequate pretreatment evaluation method. However, the {sup 99}mTc MAA SPECT image consistently shows lower TNR values compared to 90Y PET/CT, which means the possibility of underestimation of tumorous uptake in the partition dosimetry model using {sup 99}mTc MAA SPECT. Considering that

  5. Long-lived impurities of 90Y-labeled microspheres, TheraSphere and SIR-spheres, and the impact on patient dose and waste management.

    Science.gov (United States)

    Metyko, John; Williford, John M; Erwin, William; Poston, John; Jimenez, Sandra

    2012-11-01

    Yittrium-90 microsphere brachytherapy procedures have increased in number due to their efficacy in treating some unresectable metastatic liver tumors. The discovery of long-lived impurities in two microsphere products, first reported between 2006 and 2007, has resulted in some radiation safety concerns. Since then, microsphere production processes have been refined, which reportedly lead to a reduction in detectable by-products. In this study unused vials of TheraSphere and SIR-Spheres, manufactured in early January 2011, were analyzed to identify and quantify the low-level radioactive impurities. Absorbed dose calculations were performed to assess the potential increased dose to the patient due to long-lived impurities. Results showed that while the SIR-Spheres vials contained no detectable impurities (contrary to other published results in the literature), the TheraSphere vials contained 17 radionuclides in one sample and 15 in the other. The dominant impurities were Y and Y, with specific activities ranging from 0.99 ± 3.40 × 10 kBq mg to 6.30 ± 0.40 kBq mg at vendor assay date. Other impurities were on the order of Bq mg. Based on Medical Internal Radiation Dose (MIRD) liver and lung dose estimates, the long-lived impurities would be expected to increase an administered dose by less than 0.1% from the prescribed dose.

  6. Patent hepatic falciform artery detected after Tc-99m-macroaggregated albumin injection on SPECT/CT prior to Yttrium-90 microsphere radioembolization: a case report

    International Nuclear Information System (INIS)

    Karaman, B.; Aslan, A.; Hamcan, S.; Ugurel, M.

    2012-01-01

    Full text: Introduction: Yttrium-90 (Y-90) microsphere radioembolization is increasingly used for the treatment of unresectable hepatocellular carcinoma and liver metastasis. Objectives and tasks: We aim to present the upper abdominal wall skin involvement detected during routine pre-therapy Technetium-99m-macroaggregated albumin (Tc-99m-MAA) on SPECT/CT due to patent hepatic falciform artery and the precautions to avoid this potential complication. Material and methods: 38-year-old male with colon cancer and multiple liver metastasis was evaluated prior to radioembolization and Tc-99 MAA was slowly hand injected at the bifurcation of the proper hepatic artery. Then, the SPECT/CT scan was performed in order to investigate the systemic shunt or gastric involvement. Results: On SPECT/CT scan, involvement of the upper abdominal wall through falciform ligament was seen. Re-evaluation of the hepatic angiogram identified a patent hepatic falciform artery arising from the left hepatic artery. Y-90 microspheres were slowly hand injected to the left hepatic artery superselectively and no extra-hepatic activity was seen on SPECT/CT scan. Conclusion: Upper abdominal pain and dermatitis are uncommon findings after radioembolization and may occur due to inadvertent delivery of Y-90 microspheres into patent hepatic falciform artery. To prevent these complications, either patent hepatic falciform artery must be embolized by coil or Y-90 injection must be performed superselectively

  7. Temporary balloon occlusion of the common hepatic artery for administration of yttrium-90 resin microspheres in a patient with patent hepatoenteric collaterals.

    Science.gov (United States)

    Mahvash, Armeen; Zaer, Navid; Shaw, Colette; Chasen, Beth; Avritscher, Rony; Murthy, Ravi

    2012-02-01

    The most common serious complication of yttrium-90 ((90)Y) therapy is gastrointestinal ulceration caused by extrahepatic microsphere dispersion. The authors describe the use of a balloon catheter for temporary occlusion of the common hepatic artery to reverse hepatoenteric flow for lobar administration of resin microspheres when coil embolization of a retroportal artery was impossible. At 9 months after treatment, the patient had no gastrointestinal side effects and showed a partial response. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  8. Comparison of the stability of Y-90-, Lu-177- and Ga-68- labeled human serum albumin microspheres (DOTA-HSAM)

    Energy Technology Data Exchange (ETDEWEB)

    Wunderlich, Gerd [Department of Nuclear Medicine, University Hospital, 01307 Dresden (Germany); Schiller, Eik, E-mail: eisc@rotop-pharmaka.d [ROTOP Pharmaka AG, 01454 Radeberg (Germany); Bergmann, Ralf; Pietzsch, Hans-Juergen [Forschungszentrum Dresden-Rossendorf, Institute of Radiopharmacy, P.O. Box 510119, 01314 Dresden (Germany)

    2010-11-15

    Introduction: Microparticles derived from denatured human serum albumin (DOTA-derivatized human serum albumin microspheres, or DOTA-HSAM) are attractive carriers of radionuclides for both therapeutic and diagnostic purposes. In this article, we describe a labeling procedure for diagnostic (Ga-68) and therapeutic (Y-90, Lu-177) radionuclides and report on the results of stability studies of these products. Methods: DOTA-HSAM was labeled in 0.5 M ammonium acetate buffer, pH 5.0, containing 0.02 mg/ml detergent. After adding the radionuclide, the mixture was shaken for 15 min at 90{sup o}C. Labeling yields and in vitro stability were determined by thin-layer chromatography. For determination of the in vivo stability of Ga-68 and Y-90 DOTA-HSAM, the particles were injected intravenously in Wistar rats. Results: Labeling yields up to 95% in the case of Ga-68 and Lu-177 were achieved. Ga-68-labeled DOTA-HSAM showed high in vitro and in vivo stability. The amount of particle-bound radioactivity of Lu-177 DOTA-HSAM declines slowly in a linear manner to approximately 72% after 13 days. For Y-90, the labeling yield decreased with increasing radioactivity level. We presume radiolysis as the reason for these findings. Conclusion: The labeling of DOTA-HSAM with different radionuclides is easy to perform. The radiation-induced cleavage of the labeled chelator together with the rather short half-life of radioactivity fixation in vivo (3.7 days) is, in our opinion, opposed to therapeutic applications of DOTA-HSAM. On the other hand, the high stability of Ga-68 DOTA-HSAM makes them an attractive candidate for the measurement of regional perfusion by PET.

  9. Comparison of the stability of Y-90-, Lu-177- and Ga-68- labeled human serum albumin microspheres (DOTA-HSAM)

    International Nuclear Information System (INIS)

    Wunderlich, Gerd; Schiller, Eik; Bergmann, Ralf; Pietzsch, Hans-Juergen

    2010-01-01

    Introduction: Microparticles derived from denatured human serum albumin (DOTA-derivatized human serum albumin microspheres, or DOTA-HSAM) are attractive carriers of radionuclides for both therapeutic and diagnostic purposes. In this article, we describe a labeling procedure for diagnostic (Ga-68) and therapeutic (Y-90, Lu-177) radionuclides and report on the results of stability studies of these products. Methods: DOTA-HSAM was labeled in 0.5 M ammonium acetate buffer, pH 5.0, containing 0.02 mg/ml detergent. After adding the radionuclide, the mixture was shaken for 15 min at 90 o C. Labeling yields and in vitro stability were determined by thin-layer chromatography. For determination of the in vivo stability of Ga-68 and Y-90 DOTA-HSAM, the particles were injected intravenously in Wistar rats. Results: Labeling yields up to 95% in the case of Ga-68 and Lu-177 were achieved. Ga-68-labeled DOTA-HSAM showed high in vitro and in vivo stability. The amount of particle-bound radioactivity of Lu-177 DOTA-HSAM declines slowly in a linear manner to approximately 72% after 13 days. For Y-90, the labeling yield decreased with increasing radioactivity level. We presume radiolysis as the reason for these findings. Conclusion: The labeling of DOTA-HSAM with different radionuclides is easy to perform. The radiation-induced cleavage of the labeled chelator together with the rather short half-life of radioactivity fixation in vivo (3.7 days) is, in our opinion, opposed to therapeutic applications of DOTA-HSAM. On the other hand, the high stability of Ga-68 DOTA-HSAM makes them an attractive candidate for the measurement of regional perfusion by PET.

  10. Booted selective internal radiation therapy (B-SIRT) using 90Y-loaded glass microspheres induces prolonged overall survival for PVT patients

    International Nuclear Information System (INIS)

    Garin, E.; Lenoir, L.; Edeline, J.; Laffont, S.; Mesbah, H.; Poree, P.; Boucher, E.; Rolland, Y.

    2015-01-01

    Full text of publication follows. Goal: evaluation of the response rate and survival of hepatocellular carcinoma PVT patients treated with Therasphere using the boost concept. Material and methods: Therasphere was administered in 40 PVT hepatocellular carcinoma patients (main = 11, lobar = 23, segmental = 6). MAA SPECT/CT quantitative analysis was used for the calculation of the tumour dose (TD), the healthy injected liver dose (HLD) and the injected liver dose (LD). Response was evaluated at 3 months using EASL criterion. OS was evaluated using Kaplan and Meyer tests. Results: Mean 90 Y-loaded microspheres injected activity was 3.1 ± 1.5 GBq. Mean LD was 143 ± 49 Gy. Median TD was 316 Gy for responding lesions versus 133 Gy for non responding lesion (p<0.0001). With a threshold TD of 205 Gy, MAA-SPECT/CT was predictive of response with a sensibility of 100%, and an overall accuracy of 90% (0FN, 4FP). Knowing the TD and the HLD, 40% of the patients received an intensification of the treatment (increase of the injected activity with the goal to achieve a TD> 205 Gy with a LD > 150 Gy and a HLD<120 Gy) with a good response rate (81%) and without increased liver grade III toxicity (6.2% as against 12.5% in the non boosted patients, ns). 6 patients were put aside, 5 received a lobar hepatectomy. Median OS was 18.2 months [12-27]. It was 4 m [12-27] for patients with a TD < 205 Gy versus 21.5 m [12-28.5] for patients with a TD > 205 Gy. OS was 12 m [3-∞] for patients with main PVT versus 21.5 m [12-28.7] for patients segmental or lobar PVT (ns). Finally Os was 23.2 m for patients with a TD > 205 Gy and a good PVT targeting (n = 34). Conclusion: boosted selective internal radiation therapy using 90 Y-loaded glass microspheres induces prolonged overall survival for PVT patients without increasing liver toxicity. (authors)

  11. Gastric injury from 90Y to left hepatic lobe tumors adjacent to the stomach: fact or fiction?

    International Nuclear Information System (INIS)

    Gates, Vanessa L.; Hickey, Ryan; Marshall, Karen; Williams, Melissa; Salzig, Krystina; Lewandowski, Robert J.; Salem, Riad

    2015-01-01

    Radioembolization with 90 Y microspheres is a locoregional radiation therapy for unresectable hepatic neoplasm. Non-target delivery of 90 Y microspheres resulting in gastrointestinal (GI) symptoms is a recognized complication; there is minimal knowledge regarding the radiation effect to the gastric wall from left hepatic lobe 90 Y treatments. Our aim was to study the incidence of GI complications when the target tissue (hepatic parenchyma ± tumor) is in close proximity to the gastric wall. We hypothesized that liver (tumor) to stomach proximity does not correlate with increased toxicity. Between November 2011 and September 2013, we studied all patients who underwent left lobe radioembolization with 90 Y glass microspheres. With Institutional Review Board (IRB) approval, we retrospectively reviewed MRI/CT images of these patients, identifying a subset of patients with the left hepatic lobe <1 cm from the gastric wall. Patients were seen in clinic 1 month posttreatment and subsequently at 3-month intervals. Short- and long-term gastric adverse events were tabulated. Ninety-seven patients successfully underwent left hepatic lobe 90 Y microsphere radioembolization in which the average distance from the liver to the stomach wall was 1.0 ± 2.8 mm. The average dose for patients who received radioembolization to the left hepatic lobe was 109 ± 57 Gy. Fifty patients had tumor within 1 cm of the gastric wall. The average dose for patients who received radioembolization to the left hepatic lobe with tumor within 1 cm of the gastric wall was 121 ± 41 Gy. There were no reportable or recordable medical events. Of the patients, 34 % reported abdominal pain that was grade 1-2; 65 % of the patients reported no abdominal pain. None of the 97 patients developed a clinically evident GI ulcer. Patients with left lobe tumors adjacent to or abutting the stomach do not exhibit acute or chronic radiation effects following radioembolization with glass microspheres. (orig.)

  12. Yttrium-90 radioembolization of hepatocellular carcinoma and metastatic disease to the liver.

    Science.gov (United States)

    Lewandowski, Robert J; Salem, Riad

    2006-03-01

    Yttrium-90 ((90)Y) radioembolization is a catheter-based therapy that delivers internal radiation to hepatic tumors in the form of microspheres. (90)Y can be delivered to the hepatic tumor as either a constituent of a glass microsphere, TheraSphere(®), or as a biocompatible resin-based microsphere, SIR-Spheres(®). Once embedded within the tumor microcirculation, these microspheres emit β-radiation at therapeutic levels. While the technical aspects of radioembolization are quite complex, the collective clinical experience presented in the literature supports the use of (90)Y radioembolization for unresectable hepatic malignancies.

  13. Yttrium-90 microspheres (TheraSphere) treatment of unresectable hepatocellular carcinoma: downstaging to resection, RFA and bridge to transplantation.

    Science.gov (United States)

    Kulik, Laura M; Atassi, Bassel; van Holsbeeck, Lodewijk; Souman, Tameem; Lewandowski, Robert J; Mulcahy, Mary F; Hunter, Russell D; Nemcek, Albert A; Abecassis, Michael M; Haines, Kenneth G; Salem, Riad

    2006-12-01

    To present the clinical data of 35 patients with T3 unresectable hepatocellular carcinoma (HCC) that were treated with (90)Y with the specific intent of downstaging to resection, radiofrequency ablation (RFA) candidate, United Network for Organ Sharing (UNOS) stage T2 or liver transplantation. One hundred fifty patients with unresectable HCC were treated with (90)Y microspheres. Of these, 35 patients were UNOS stage T3 at the time of treatment. Patients were followed for clinical toxicities, alterations in model for end-stage-liver disease (MELD) score, tumor response, downstaging to RFA, resection, transplantation, and survival. Nineteen of 34 patients (56%) were successfully downstaged from T3 to T2 following treatment. 11 of 34 (32%) patients treated were downstaged to target lesions measuring 3.0 cm or less. Twenty-three of 35 (66%) were downstaged to either T2 status, lesion < 3.0 cm (RFA candidate), or resection. Seventeen of 34 (50%) had an objective tumor response by WHO criteria. Eight patients (23%) were successfully downstaged and underwent OLT following treatment. 1, 2, and 3-year survival was 84%, 54%, and 27%, respectively. Median survival by Kaplan-Meier analysis for the entire cohort was 800 days. These data suggest that intra-arterial (90)Y microspheres can be used as a bridge to transplantation, surgical resection, or RFA. (c) 2006 Wiley-Liss, Inc.

  14. Collimator and energy window optimization for 90Y bremsstrahlung SPECT imaging: A SIMIND Monte Carlo study

    International Nuclear Information System (INIS)

    Roshan, Hoda Rezaei; Mahmoudian, Babak; Gharepapagh, Esmaeil; Azarm, Ahmadreza; Pirayesh Islamian, Jalil

    2016-01-01

    Treatment efficacy of radioembolization using Yttrium-90 ( 90 Y) microspheres is assessed by the 90 Y bremsstrahlung single photon emission computed tomography (SPECT) imaging following radioembolization. The radioisotopic image has the potential of providing reliable activity map of 90 Y microspheres distribution. One of the main reasons of the poor image quality in 90 Y bremsstrahlung SPECT imaging is the continuous and broad energy spectrum of the related bremsstrahlung photons. Furthermore, collimator geometry plays an impressive role in the spatial resolution, sensitivity and image contrast. Due to the relatively poor quality of the 90 Y bremsstrahlung SPECT images, we intend to optimize the medium-energy (ME) parallel-hole collimator and energy window. The Siemens e.cam gamma camera equipped with a ME collimator and a voxelized phantom was simulated by the SImulating Medical Imaging Nuclear Detectors (SIMIND) program. We used the SIMIND Monte Carlo program to generate the 90 Y bremsstrahlung SPECT projection of the digital Jaszczak phantom. The phantom consist of the six hot spheres ranging from 9.5 to 31.8 mm in diameter, which are used to evaluate the image contrast. In order to assess the effect of the energy window on the image contrast, three energy windows ranging from 60 to 160 KeV, 160 to 400 KeV, and 60 to 400 KeV were set on a 90 Y bremsstrahlung spectrum. As well, the effect of the hole diameter of a ME collimator on the image contrast and bremsstrahlung spectrum were investigated. For the fixed collimator and septa thickness values (3.28 cm and 1.14 mm, respectively), a hole diameter range (2.35–3.3 mm) was chosen based on the appropriate balance between the spatial resolution and sensitivity. The optimal energy window for 90 Y bremsstrahlung SPECT imaging was extended energy window from 60 to 400 KeV. Besides, The optimal value of the hole diameter of ME collimator was obtained 3.3 mm. Geometry of the ME parallel-hole collimator and energy

  15. Gastric injury from {sup 90}Y to left hepatic lobe tumors adjacent to the stomach: fact or fiction?

    Energy Technology Data Exchange (ETDEWEB)

    Gates, Vanessa L.; Hickey, Ryan; Marshall, Karen; Williams, Melissa; Salzig, Krystina; Lewandowski, Robert J. [Robert H. Lurie Comprehensive Cancer Center, Department of Radiology, Section of Interventional Radiology, Northwestern Memorial Hospital, Chicago, IL (United States); Salem, Riad [Robert H. Lurie Comprehensive Cancer Center, Department of Radiology, Section of Interventional Radiology, Northwestern Memorial Hospital, Chicago, IL (United States); Northwestern University, Department of Medicine, Division of Hematology and Oncology, Robert H. Lurie Comprehensive Cancer Center, Chicago, IL (United States)

    2015-12-15

    Radioembolization with {sup 90}Y microspheres is a locoregional radiation therapy for unresectable hepatic neoplasm. Non-target delivery of {sup 90}Y microspheres resulting in gastrointestinal (GI) symptoms is a recognized complication; there is minimal knowledge regarding the radiation effect to the gastric wall from left hepatic lobe {sup 90}Y treatments. Our aim was to study the incidence of GI complications when the target tissue (hepatic parenchyma ± tumor) is in close proximity to the gastric wall. We hypothesized that liver (tumor) to stomach proximity does not correlate with increased toxicity. Between November 2011 and September 2013, we studied all patients who underwent left lobe radioembolization with {sup 90}Y glass microspheres. With Institutional Review Board (IRB) approval, we retrospectively reviewed MRI/CT images of these patients, identifying a subset of patients with the left hepatic lobe <1 cm from the gastric wall. Patients were seen in clinic 1 month posttreatment and subsequently at 3-month intervals. Short- and long-term gastric adverse events were tabulated. Ninety-seven patients successfully underwent left hepatic lobe {sup 90}Y microsphere radioembolization in which the average distance from the liver to the stomach wall was 1.0 ± 2.8 mm. The average dose for patients who received radioembolization to the left hepatic lobe was 109 ± 57 Gy. Fifty patients had tumor within 1 cm of the gastric wall. The average dose for patients who received radioembolization to the left hepatic lobe with tumor within 1 cm of the gastric wall was 121 ± 41 Gy. There were no reportable or recordable medical events. Of the patients, 34 % reported abdominal pain that was grade 1-2; 65 % of the patients reported no abdominal pain. None of the 97 patients developed a clinically evident GI ulcer. Patients with left lobe tumors adjacent to or abutting the stomach do not exhibit acute or chronic radiation effects following radioembolization with glass

  16. Trisacryl Gelatin Microspheres Versus Polyvinyl Alcohol Particles in the Preoperative Embolization of Bone Neoplasms

    International Nuclear Information System (INIS)

    Basile, Antonio; Rand, Thomas; Lomoschitz, Fritz; Toma, Cyril; Lupattelli, Tommaso; Kettenbach, Joachim; Lammer, Johannes

    2004-01-01

    The aim of this study was to compare the efficacy of trisacryl gelatin microspheres versus polyvinyl alcohol particles (PVA) in the preoperative embolization of bone neoplasms, on the basis of intraoperative blood loss quantified by the differences in preoperative and postoperative hematic levels of hemoglobin, hematocrit and erythrocytes count. From January 1997 to December 2002, preoperative embolization of bone tumors (either primary or secondary) was carried out in 49 patients (age range 12/78), 20 of whom were treated with trysacril gelatin microspheres (group A) and 29 with PVA particles (group B). The delay between embolization and surgery ranged from 1 to 13 days in group A and 1 to 4 days in group B. As used in international protocols, we considered hematic levels of hemoglobin, hematocrit and erythrocytes count for the measurement of intraoperative blood loss then the differences in pre- and postoperative levels were used as statistical comparative parameters. We compared the values of patients treated with embospheres (n = 10) and PVA (n = 18) alone, and patients treated with (group A = 10; group B = 11) versus patients treated without other additional embolic materials in each group (group A = 10; group B = 18). According to the Student's t-test (p < 0.05), the difference of hematic parameters between patients treated by embospheres and PVA alone were significant; otherwise there was no significant difference between patients treated with only one embolic material (embospheres and PVA) versus those treated with other additional embolic agents in each group. The patients treated with microspheres had a minor quantification of intraoperative blood loss compared to those who received PVA particles. Furthermore, they had a minor increase of bleeding related to the delay time between embolization and surgery. The use of additional embolic material did not improve the efficacy of the procedure in either group of patients

  17. Clinical impact of 99mTc-MAA SPECT/CT-based dosimetry in the radioembolization of liver malignancies with 90Y-loaded microspheres

    International Nuclear Information System (INIS)

    Garin, Etienne; Rolland, Yan; Laffont, Sophie; Edeline, Julien

    2016-01-01

    Radioembolization with 90 Y-loaded microspheres is increasingly used in the treatment of primary and secondary liver cancer. Technetium-99 m macroaggregated albumin (MAA) scintigraphy is used as a surrogate of microsphere distribution to assess lung or digestive shunting prior to therapy, based on tumoral targeting and dosimetry. To date, this has been the sole pre-therapeutic tool available for such evaluation. Several dosimetric approaches have been described using both glass and resin microspheres in hepatocellular carcinoma (HCC) and liver metastasis. Given that each product offers different specific activities and numbers of spheres injected, their radiobiological properties are believed to lightly differ. This paper summarizes and discusses the available studies focused on MAA-based dosimetry, particularly concentrating on potential confounding factors like clinical context, tumor size, cirrhosis, previous or concomitant therapy, and product used. In terms of the impact of tumoral dose in HCC, the results were concordant and a response relationship and tumoral threshold dose was clearly identified, especially in studies using glass microspheres. Tumoral dose has also been found to influence survival. The concept of treatment intensification has recently been introduced, yet despite several studies publishing interesting findings on the tumor dose-metastasis relationship, no consensus has been reached, and further clarification is thus required. Nor has the maximal tolerated dose to the liver been well documented, requiring more accurate evaluation. Lung dose was well described, despite recently identified factors influencing its evaluation, requiring further assessment. MAA SPECT/CT dosimetry is accurate in HCC and can now be used in order to achieve a fully customized approach, including treatment intensification. Yet further studies are warranted for the metastasis setting and evaluating the maximal tolerated liver dose. (orig.)

  18. Intra-arterial treatment with ⁹⁰Y microspheres for hepatocellular carcinoma: 4 years experience at the Ghent University Hospital.

    Science.gov (United States)

    Lambert, Bieke; Sturm, Emiel; Mertens, Jeroen; Oltenfreiter, Ruth; Smeets, Peter; Troisi, Roberto; Van Vlierberghe, Hans; Defreyne, Luc

    2011-12-01

    We report on our experience in terms of eligibility, safety, response and survival for treatment of hepatocellular carcinoma (HCC) with (90)Y microspheres. Secondly, we investigated the urinary excretion of (90)Y following treatment. We retrospectively reviewed all HCC patients referred to our department for (90)Y microsphere treatment. We recorded reasons for not proceeding to actual treatment. In case treatment was performed, we assessed the tolerance (Common Terminology Criteria for Adverse Events v3.0, CTCAE v3.0), the response [modified Response Evaluation Criteria in Solid Tumors (mRECIST) criteria] and long-term survival (Kaplan-Meier). The urinary excretion was estimated by 12-h urine collections post-injection for analysis in a gamma counter. Forty-three HCC patients were referred for radioembolization. Fourteen patients were excluded, mainly due to unfavourable (99m)Tc-macroaggregated albumin (MAA) distribution. Twenty-nine patients were treated with (90)Y microspheres (TheraSphere, mean activity 2.17 GBq). In four patients severe clinical adverse events were encountered, however only in one case clearly related to the therapy. Twenty patients were assessable by mRECIST: complete response in 15%, partial response in 35%, stable disease in 30% and progression in 20% were observed. A median survival of 12.3 months (95% confidence interval 9.4-15.2) was estimated. Concerning the substudy on urinary excretion, only 0.0025% of the administered activity was excreted in the urine within the first 12 h following TheraSphere. Following a strict workup before admitting patients to radioembolization with TheraSphere, we found good clinical tolerance in the vast majority of patients. Radiological response assessment yielded an overall response rate of 50%, when evaluated early following treatment. Urine analysis showed consistently only low activities of (90)Y excreted in the urine.

  19. Dose-response evaluation after Yttrium-90 resin microsphere radio-embolization of breast cancer liver metastases

    International Nuclear Information System (INIS)

    Gnesin, S.; Verdun, F.R.; Baechler, S.; Boubacker, A.; Adib, S.; Cherbuin, N.; Prior, J.O.; Bize, P.; Denys, A.

    2015-01-01

    Full text of publication follows. Aim: Yttrium-90 resin microsphere radio-embolization is a valuable therapeutic option in metastatic breast cancer patients with progressive disease refractory to chemotherapy. The goal of this study was to evaluate the dose-response relationship of liver metastasis based on a 3D voxelized 90 Y PET dosimetry. Materials and methods: we studied the dose-response relationship of twelve hepatic lesions in four selected patients with metastatic breast cancer who underwent 90 Y radio-embolization (Sirtex SIR-Spheres Pty Ltd.). The administered activity ranged from 1 to 1.3 GBq. Ten days before treatment, patients underwent a baseline 18 F-FDG PET/CT. The determination of the 90 Y-microsphere activity to administer for treatment was based on the BSA method refined with the partition model derived from a 99m Tc-MAA SPECT/CT performed a week prior to radio-embolization. Within 24 hours after treatment, 90 Y TOF PET/CT imaging was performed. A follow-up 18 F-FDG PET/CT was performed 1 month after the treatment to evaluate the response to radio-embolization. For each patient, 3D voxelized dose-maps were obtained from the post-treatment 90 Y TOF PET/CT. A volume of interest (VOI) was drawn for each selected hepatic lesion using the baseline 18 F-FDG PET/CT. To obtain dose-volume histogram (DVH) for each lesion, image co-registration and VOI masks were generated using the PMOD 3.4 software and then exported in Matlab for dose calculation. Furthermore, the average absorbed dose in lesions was corrected for PVE effects by multiplication for appropriate (phantom-based) recovery coefficients according to the lesion size. Early metabolic lesion response was assessed in terms of variation in the maximum standard uptake value (ΔSUVmax) between baseline and follow-up 18 F-FDG PET/CT. The average absorbed dose for each lesion was associated with the respective metabolic response. Results: for the 12 selected lesions, the average volume was 35 cm 3

  20. WE-AB-BRA-05: PET-Guided Delivery Quality Evaluation of Yttrium-90 Microsphere Radioembolizaton for Hepatocellular Carcinoma Patients: The Optimal Sequence of Radioembolizaton and Chemoembolization Treatments

    Energy Technology Data Exchange (ETDEWEB)

    Lin, M [The University of Texas Southwestern Medical Ctr, Dallas, TX (United States); Saboury, B [University of Maryland School of Medicine, Baltimore, MD (United States)

    2016-06-15

    Purpose: Selective-internal-radiation-therapy (SIRT) and transarterial-chemoembolization (TACE) are commonly used for treatment of liver tumors. The use of TACE, which is macroembolic, prior to SIRT may cause hemodynamic changes in tumor vasculature that impair yttrium-90 (90Y) microsphere delivery to the targeted lesions. This work aims to quantify dosimetric tumor coverage using 90Y positron emission tomography (PET) dosimetry after SIRT alone compared to TACE followed by SIRT. Methods: A total of 40 consecutive hepatocellular carcinoma (HCC) SIRT patients who had a post-SIRT 90Y PET/CT scan were evaluated. The patient-specific-3D-dose was reconstructed from the PET images. Patients were categorized into two groups: patients received TACE prior SIRT procedure (n=18) and patient received SIRT alone (n=22). The lesions and liver were delineated by a senior radiologist. We evaluated both the lesion-specific dose-volume-histogram (DVH) and the selectivity index (SI) defined as the ratio of the average dose inside the total lesion(s) and the average dose of the normal liver. The SI values of patients were compared based on whether TACE was previously used. Results: A wide spectrum was observed in the lesion-specific DVH-evaluation and SI appeared to be suitable of evaluating the quality of each SIRT infusion. The average SI of the entire patient group was 3.0, i.e. targeted lesion receiving three times higher dose than normal liver. The average SI was 1.8 for patients who had prior TACE and 3.9 for patients who did not have prior TACE (p=0.008). 85% of the patients with prior TACE demonstrated poor 90Y-microsphere delivery (SI <2) while none demonstrated excellent delivery (SI >4). On the other hand, the incidence SI >4 among patients with no prior TACE was 37%. Conclusion: 3D dose evaluation using post-SIRT PET suggests that 90Y microsphere delivery to liver tumors is impaired among patients who received prior TACE compared to those who receive SIRT alone.

  1. Clinical impact of {sup 99m}Tc-MAA SPECT/CT-based dosimetry in the radioembolization of liver malignancies with {sup 90}Y-loaded microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Garin, Etienne [Cancer Institute Eugene Marquis, Department of Nuclear Medicine, Rennes (France); University of Rennes 1, Rennes (France); INSERM, U-991, Liver Metabolisms and Cancer, Rennes (France); Rolland, Yan [Cancer Institute Eugene Marquis, Department of Medical Imaging, Rennes (France); Laffont, Sophie [University of Rennes 1, Rennes (France); Edeline, Julien [University of Rennes 1, Rennes (France); INSERM, U-991, Liver Metabolisms and Cancer, Rennes (France); Cancer Institute Eugene Marquis, Department of Medical Oncology, Rennes (France)

    2016-03-15

    Radioembolization with {sup 90}Y-loaded microspheres is increasingly used in the treatment of primary and secondary liver cancer. Technetium-99 m macroaggregated albumin (MAA) scintigraphy is used as a surrogate of microsphere distribution to assess lung or digestive shunting prior to therapy, based on tumoral targeting and dosimetry. To date, this has been the sole pre-therapeutic tool available for such evaluation. Several dosimetric approaches have been described using both glass and resin microspheres in hepatocellular carcinoma (HCC) and liver metastasis. Given that each product offers different specific activities and numbers of spheres injected, their radiobiological properties are believed to lightly differ. This paper summarizes and discusses the available studies focused on MAA-based dosimetry, particularly concentrating on potential confounding factors like clinical context, tumor size, cirrhosis, previous or concomitant therapy, and product used. In terms of the impact of tumoral dose in HCC, the results were concordant and a response relationship and tumoral threshold dose was clearly identified, especially in studies using glass microspheres. Tumoral dose has also been found to influence survival. The concept of treatment intensification has recently been introduced, yet despite several studies publishing interesting findings on the tumor dose-metastasis relationship, no consensus has been reached, and further clarification is thus required. Nor has the maximal tolerated dose to the liver been well documented, requiring more accurate evaluation. Lung dose was well described, despite recently identified factors influencing its evaluation, requiring further assessment. MAA SPECT/CT dosimetry is accurate in HCC and can now be used in order to achieve a fully customized approach, including treatment intensification. Yet further studies are warranted for the metastasis setting and evaluating the maximal tolerated liver dose. (orig.)

  2. Recommendations for radioembolisation after liver surgery using yttrium-90 resin microspheres based on a survey of an international expert panel

    International Nuclear Information System (INIS)

    Samim, Morsal; Veenendaal, Linde M. van; Braat, Manon N.G.J.A.; Hoven, Andor F. van den; Bosch, Maurice A.A.J. van den; Lam, Marnix G.E.H.; Hillegersberg, Richard van; Sangro, Bruno; Kao, Yung Hsiang; Liu, Dave; Louie, John D.; Sze, Daniel Y.; Rose, Steven C.; Brown, Daniel B.; Ahmadzadehfar, Hojjat; Kim, Edward

    2017-01-01

    Guidelines on how to adjust activity in patients with a history of liver surgery who are undergoing yttrium-90 radioembolisation ( 90 Y-RE) are lacking. The aim was to study the variability in activity prescription in these patients, between centres with extensive experience using resin microspheres 90 Y-RE, and to draw recommendations on activity prescription based on an expert consensus. The variability in activity prescription between centres was investigated by a survey of international experts in the field of 90 Y-RE. Six representative post-surgical patients (i.e. comparable activity prescription, different outcome) were selected. Information on patients' disease characteristics and data needed for activity calculation was presented to the expert panel. Reported was the used method for activity prescription and whether, how and why activity reduction was found indicated. Ten experts took part in the survey. Recommendations on activity reduction were highly variable between the expert panel. The median intra-patient range was 44 Gy (range 18-55 Gy). Reductions in prescribed activity were recommended in 68% of the cases. In consensus, a maximum D Target of 50 Gy was recommended. With a current lack of guidelines, large variability in activity prescription in post-surgical patients undergoing 90 Y-RE exists. In consensus, D Target ≤50 Gy is recommended. (orig.)

  3. Boosted selective internal radiation therapy with 90Y-loaded glass microspheres (B-SIRT) for hepatocellular carcinoma patients: a new personalized promising concept

    International Nuclear Information System (INIS)

    Garin, E.; Lenoir, L.; Edeline, J.; Laffont, S.; Mesbah, H.; Poree, P.; Sulpice, L.; Boudjema, K.; Mesbah, M.; Guillygomarc'h, A.; Quehen, E.; Pracht, M.; Raoul, J.L.; Clement, B.; Rolland, Y.; Boucher, E.

    2013-01-01

    To evaluate the impact of dosimetry based on MAA SPECT/CT for the prediction of response, toxicity and survival, and for treatment planning in patients with hepatocellular carcinoma (HCC) treated with 90 Y-loaded glass microspheres (TheraSphere registered). TheraSphere registered was administered to 71 patients with inoperable HCC. MAA SPECT/CT quantitative analysis was used for the calculation of the tumour dose (TD), healthy injected liver dose (HILD), and total injected liver dose. Response was evaluated at 3 months using EASL criteria. Time to progression (TTP) and overall survival (OS) were evaluated using the Kaplan-Meier method. Factors potentially associated with liver toxicity were combined to construct a liver toxicity score (LTS). The response rate was 78.8 %. Median TD were 342 Gy for responding lesions and 191 Gy for nonresponding lesions (p 205 Gy (p = 0.0015 and not significant). Among patients with portal vein thrombosis (PVT) (n = 33), the median TTP and OS were 4.5 months (2-7 months) and 5 months (2-8 months), respectively, in patients with TD 205 Gy (p = 0.039 and 0.005). The median OS was 24.5 months (18-28.5 months) in PVT patients with TD >205 Gy and good PVT targeting on MAA SPECT/CT. The LTS was able to detect severe liver toxicity (n = 6) with a sensitivity of 83 % and overall accuracy of 97 %. Dosimetry based on MAA SPECT/CT was able to accurately predict response and survival in patients treated with glass microspheres. This method can be used to adapt the injected activity without increasing liver toxicity, thus defining a new concept of boosted selective internal radiation therapy (B-SIRT). This new concept and LTS enable fully personalized treatment planning with glass microspheres to be achieved. (orig.)

  4. Boosted selective internal radiation therapy with 90Y-loaded glass microspheres (B-SIRT) for hepatocellular carcinoma patients: a new personalized promising concept.

    Science.gov (United States)

    Garin, E; Lenoir, L; Edeline, J; Laffont, S; Mesbah, H; Porée, P; Sulpice, L; Boudjema, K; Mesbah, M; Guillygomarc'h, A; Quehen, E; Pracht, M; Raoul, J L; Clement, B; Rolland, Y; Boucher, E

    2013-07-01

    To evaluate the impact of dosimetry based on MAA SPECT/CT for the prediction of response, toxicity and survival, and for treatment planning in patients with hepatocellular carcinoma (HCC) treated with (90)Y-loaded glass microspheres (TheraSphere®). TheraSphere® was administered to 71 patients with inoperable HCC. MAA SPECT/CT quantitative analysis was used for the calculation of the tumour dose (TD), healthy injected liver dose (HILD), and total injected liver dose. Response was evaluated at 3 months using EASL criteria. Time to progression (TTP) and overall survival (OS) were evaluated using the Kaplan-Meier method. Factors potentially associated with liver toxicity were combined to construct a liver toxicity score (LTS). The response rate was 78.8%. Median TD were 342 Gy for responding lesions and 191 Gy for nonresponding lesions (p 205 Gy (p = 0.0015 and not significant). Among patients with portal vein thrombosis (PVT) (n = 33), the median TTP and OS were 4.5 months (2-7 months) and 5 months (2-8 months), respectively, in patients with TD 205 Gy (p = 0.039 and 0.005). The median OS was 24.5 months (18-28.5 months) in PVT patients with TD >205 Gy and good PVT targeting on MAA SPECT/CT. The LTS was able to detect severe liver toxicity (n = 6) with a sensitivity of 83% and overall accuracy of 97%. Dosimetry based on MAA SPECT/CT was able to accurately predict response and survival in patients treated with glass microspheres. This method can be used to adapt the injected activity without increasing liver toxicity, thus defining a new concept of boosted selective internal radiation therapy (B-SIRT). This new concept and LTS enable fully personalized treatment planning with glass microspheres to be achieved.

  5. Country report: Syria. Development of 90Y/90Sr Generator and 90Y Radiopharmaceuticals

    International Nuclear Information System (INIS)

    Yassine, Taufik; Mukhallalati, Ch. Heyam

    2010-01-01

    The aim of this project is to develop a technique for preparation of 90 Sr- 90 Y generator, we have developed a separation technique for isolation of 90 Y from 90 Sr based on using Sr – Spec resin packed in three columns for separation and purification of 90 Sr- 90 Y .The resulting Y90 is used for therapeutic applications. The first part of this project describe a prototype design for the 90 Sr- 90 Y generator in order to get a very accurate method to obtain the minimum possible 90 Sr Breakthrough. 25 mci of 90 Sr was used in the generator 90 Sr- 90 Y and we obtained the elution yield of 90 Y higher than 88%, Also the eluate was used for preparation of several 90 Y radiopharmaceuticals such as 90 YEDTMP and 90 Y-DOTA-HR 3 . And the work is continues to investigate more radiopharmaceuticals applications in the second part of this project such as 90 Y– FHMA. In this part of the co-coordination research programmer, A protocol based on results of this studies was developed to prepare and operate a higher activity generator (50-100mci), the resulting elution yield was approximately 94% of 90 Y . The elute was used in preparation of new 90 Y radiopharmaceuticals. The monoclonal antibodies is still evolving by conjugate Rituximab to The macrocyclic bifunctional chelating agent,(p-SCN-Bn-DOTA)S-2-(4-Isothiocyanatobenzyle)-1,4,7,10- tetraazacyclododecane-tetraaceticacid to obtain the inmunoconjugate DOTA-Rituximub in simple way and then investigating the radio labeling conditions with 90 Y. (author)

  6. Complexation studies with 90Y from a novel 90Sr-90Y generator

    International Nuclear Information System (INIS)

    Venkatesh, M.; Pandey, U.; Banerjee, S.; Samuel, G.; Pillai, M.R.A.; Dhami, P.S.; Kannan, R.; Achuthan, P.V.; Chitnis, R.R.; Gopalakrishnan, V.; Ramanujam, A.

    2001-01-01

    Some features of a novel 90 Sr- 90 Y generator which employs supported liquid membrane (SLM) to separate carrier-free 90 Y from 90 Sr present in the high level waste of the spent fuel of reactor are described. After ascertaining the purity of 90 Y particularly with respect to 90 Sr breakthrough, its complexation was studied with a few oxo/aza donor ligands, such as DTPA, EDTMP, DOTA, TETA and a cyclic phosphonate, CTMP. These studies were primarily carried out to adjudge the quality of the 90 Y obtained from a novel 90 Sr- 90 Y generator and ascertain its usability for labelling biomolecules such as antibodies and peptides. The DOTA complexes are most stable at 37 C in human serum; they appear to be ideal bifunctional chelating agent for use in radioimmunotherapy with 90 Y. (orig.)

  7. Development and evaluation of holmium doped phosphate glass microspheres for selective internal radiotherapy

    International Nuclear Information System (INIS)

    Barros Filho, Eraldo C.; Martinelli, Jose Roberto; Squair, Peterson L; Osso Junior, Joao A.; Sene, Frank Ferrer

    2013-01-01

    Selective Internal Radiotherapy is used to treat hepatocellular carcinoma. In this treatment 90 Y -doped aluminosilicate glass microspheres are introduced in the hepatic artery and they migrate to the liver near to the tumor where they are trapped in the arterioles. The radiation β- emitted by the decay of 90 Y annihilates the cancer cells. A macroaggregate of albumin containing technetium is previously used to monitor the lung shunt and to prevent the spreading of 90 Y during the treatment. In the present work, 165 Ho- doped phosphate glass microspheres were developed aiming that application. 165 Ho has high cross section for neutron capture (64 bars) and 166 Ho decays emitting β- radiation with appropriate energy for killing cancer cells, and gamma rays with low energy which can be used to obtain images of the microspheres location and to check possible occurrence of lung shunt. Holmium also is highly paramagnetic and can be used to obtain images whereby NMR. The glass matrix consists of (P 2 O 5 ) tetrahedrons and can be produced by a relatively lower melting temperature of chemical compounds. The 31 P decays by emitting β- radiation and contributes to the absorbed dose, helping to annihilate the cancer cells. The microspheres were produced by using two methods: the flame and the gravitation falling methods to obtain microspheres with appropriate properties. (author)

  8. Recommendations for radioembolisation after liver surgery using yttrium-90 resin microspheres based on a survey of an international expert panel

    Energy Technology Data Exchange (ETDEWEB)

    Samim, Morsal [University Medical Center Utrecht, Department of Surgery, Utrecht (Netherlands); University Medical Center Utrecht, Department of Radiology and Nuclear Medicine, Utrecht (Netherlands); Veenendaal, Linde M. van; Braat, Manon N.G.J.A.; Hoven, Andor F. van den; Bosch, Maurice A.A.J. van den; Lam, Marnix G.E.H. [University Medical Center Utrecht, Department of Radiology and Nuclear Medicine, Utrecht (Netherlands); Hillegersberg, Richard van [University Medical Center Utrecht, Department of Surgery, Utrecht (Netherlands); Sangro, Bruno [Clinica Universidad de Navarra-IDISNA and CIBEREHD, Liver Unit, Pamplona (Spain); Kao, Yung Hsiang [Cabrini Hospital, Department of Nuclear Medicine, Melbourne (Australia); Liu, Dave [Vancouver General Hospital, University of British Columbia, Department of Radiology, Vancouver, British Columbia (Canada); Louie, John D.; Sze, Daniel Y. [Stanford University Medical Center, Division of Interventional Radiology, Stanford (United States); Rose, Steven C. [University of California, Department of Radiology, San Diego (United States); Brown, Daniel B. [Vanderbilt University, Medical Center North, Department of Radiology, Nashville (United States); Ahmadzadehfar, Hojjat [University Hospital Bonn, Department of Nuclear Medicine, Bonn (Germany); Kim, Edward [Icahn School of Medicine at Mount Sinai, Division of Vascular and Interventional Radiology, New York (United States)

    2017-12-15

    Guidelines on how to adjust activity in patients with a history of liver surgery who are undergoing yttrium-90 radioembolisation ({sup 90}Y-RE) are lacking. The aim was to study the variability in activity prescription in these patients, between centres with extensive experience using resin microspheres {sup 90}Y-RE, and to draw recommendations on activity prescription based on an expert consensus. The variability in activity prescription between centres was investigated by a survey of international experts in the field of {sup 90}Y-RE. Six representative post-surgical patients (i.e. comparable activity prescription, different outcome) were selected. Information on patients' disease characteristics and data needed for activity calculation was presented to the expert panel. Reported was the used method for activity prescription and whether, how and why activity reduction was found indicated. Ten experts took part in the survey. Recommendations on activity reduction were highly variable between the expert panel. The median intra-patient range was 44 Gy (range 18-55 Gy). Reductions in prescribed activity were recommended in 68% of the cases. In consensus, a maximum D{sub Target} of 50 Gy was recommended. With a current lack of guidelines, large variability in activity prescription in post-surgical patients undergoing {sup 90}Y-RE exists. In consensus, D{sub Target} ≤50 Gy is recommended. (orig.)

  9. Determination of Radiation Absorbed Dose to Primary Liver Tumors and Normal Liver Tissue Using Post Radioembolization 90Y PET

    Directory of Open Access Journals (Sweden)

    Shyam Mohan Srinivas

    2014-10-01

    Full Text Available Background: Radioembolization with Yttrium-90 (90Y microspheres is becoming a more widely used transcatheter treatment for unresectable hepatocellular carcinoma (HCC. Using post-treatment 90Y PET/CT scans,the distribution of microspheres within the liver can be determined and quantitatively assessesed . We studied the radiation dose of 90Y delivered to liver and treated tumors.Methods: This retrospective study of 56 patients with HCC, including analysis of 98 liver tumors, measured and correlated the dose of radiation delivered to liver tumors and normal liver tissue using glass microspheres (TheraSpheres® to the frequency of complications with mRECIST. 90Y PET/CT and triphasic liver CT scans were used to contour treated tumor and normal liver regions and determine their respective activity concentrations. An absorbed dose factor was used to convert the measured activity concentration (Bq/mL to an absorbed dose (Gy.Results: The 98 studied tumors received a mean dose of 169 Gy (mode 90-120 Gy;range 0-570 Gy. Tumor response by mRECIST criteria was performed for 48 tumors that had follow up scans. There were 21 responders (mean dose 215 Gy and 27 nonresponders (mean dose 167 Gy. The association between mean tumor absorbed dose and response suggests a trend but did not reach statistical significance (p=0.099. Normal liver tissue received a mean dose of 67 Gy (mode 60-70 Gy; range 10-120 Gy. There was a statistically significant association between absorbed dose to normal liver and the presence of two or more severe complications (p=0.036.Conclusion: Our cohort of patients showed a possible dose response trend for the tumors. Collateral dose to normal liver is nontrivial and can have clinical implications. These methods help us understand whether patient adverse events, treatment success, or treatment failure can be attributed to the dose which the tumor or normal liver received.

  10. SU-D-201-05: Phantom Study to Determine Optimal PET Reconstruction Parameters for PET/MR Imaging of Y-90 Microspheres Following Radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Maughan, N [Washington University in Saint Louis, Saint Louis, MO (United States); Conti, M [Siemens Healthcare Molecular Imaging, Knoxville, TN (United States); Parikh, P [Washington Univ. School of Medicine, Saint Louis, MO (United States); Faul, D [Siemens Healthcare, New York, NY (United States); Laforest, R [Washington University School of Medicine, Saint Louis, MO (United States)

    2015-06-15

    Purpose: Imaging Y-90 microspheres with PET/MRI following hepatic radioembolization has the potential for predicting treatment outcome and, in turn, improving patient care. The positron decay branching ratio, however, is very small (32 ppm), yielding images with poor statistics even when therapy doses are used. Our purpose is to find PET reconstruction parameters that maximize the PET recovery coefficients and minimize noise. Methods: An initial 7.5 GBq of Y-90 chloride solution was used to fill an ACR phantom for measurements with a PET/MRI scanner (Siemens Biograph mMR). Four hot cylinders and a warm background activity volume of the phantom were filled with a 10:1 ratio. Phantom attenuation maps were derived from scaled CT images of the phantom and included the MR phased array coil. The phantom was imaged at six time points between 7.5–1.0 GBq total activity over a period of eight days. PET images were reconstructed via OP-OSEM with 21 subsets and varying iteration number (1–5), post-reconstruction filter size (5–10 mm), and either absolute or relative scatter correction. Recovery coefficients, SNR, and noise were measured as well as total activity in the phantom. Results: For the 120 different reconstructions, recovery coefficients ranged from 0.1–0.6 and improved with increasing iteration number and reduced post-reconstruction filter size. SNR, however, improved substantially with lower iteration numbers and larger post-reconstruction filters. From the phantom data, we found that performing 2 iterations, 21 subsets, and applying a 5 mm Gaussian post-reconstruction filter provided optimal recovery coefficients at a moderate noise level for a wide range of activity levels. Conclusion: The choice of reconstruction parameters for Y-90 PET images greatly influences both the accuracy of measurements and image quality. We have found reconstruction parameters that provide optimal recovery coefficients with minimized noise. Future work will include the effects

  11. Y-90 microspheres in the treatment of unresectable hepatocellularcarcinoma

    International Nuclear Information System (INIS)

    Al-Kalbani, A.; Kamel, Y.

    2008-01-01

    A small percentage of patients with hepatocellular carcinoma (HCC) arecandidates for curative treatment in form of resection or transplantation.There are different treatment options for unresectable HCC-like localablative therapies and recently systemic therapy with Sorafenib. All of thesehave variable response rate and had been proven to improve survival. In thelast few years, there is a growing interest in TheraSphere radioembolization.It consists of yttrium (Y-90) embedded into nonbiodegradeable glassmicrospheres. It is selectively administered by intraarterial hepaticinjection giving high doses of radiation to the tumor and sparing the liverparenchyma. It has been shown to improve survival and used as a bridge totransplantation and to downstage tumors for resection. Therasphere seems tohave favorable safety profile and has been used in patients with portal veinthrombosis with successful outcome. (author)

  12. Preparation of 90Sr-90Y generator

    International Nuclear Information System (INIS)

    Jin Xiaohai; Yu Haibin; Zhang Jinming; Zhang Peixin; Lin Qiongfang

    1990-01-01

    In recent years, 90 Y has been considered as one of the best radionuclides for tumor radioimmunotherapy when chelated to tumor-associated antibodies. This evaluation is based on the superior properties of this radionuclide (suitable half-life, pure β-ray emitter of intermediate energy, stable daughters, and suitable chemical properties) and because it is available as a radionuclide generator product by decay of its 28a parent 90 Sr. The experimental conditions of 90 Sr- 90 Y generator are described. The elution efficiency of 90 Sr- 90 Y generator reaches 98%. One of the most important problems is the 90 Sr contamination breakthrough from the generator. The level of 90 Sr contamination must be controlled to the clinical standard. The cation exchange resin 732 (100-150 mesh) was successfully used for the separation of 90 Y from 90 Sr. The method used by the authors provides a 90 Y-HAc solution which is very simple and safe for administration to the patients. 90 Y was separated from 90 Sr almost completely, the level of the 90 Sr contamination per 740 MBq 90 Y product was only 0.74 kBq. However the toxicity of 90 Sr is extremely high, the human life-time permissible dose is 74 kBq, then 740 MBq of 90 Y is allowed to be administrated to a patient for 50-100 times

  13. Radioembolization of hepatocarcinoma with 90Y glass microspheres: development of an individualized treatment planning strategy based on dosimetry and radiobiology

    International Nuclear Information System (INIS)

    Chiesa, C.; Maccauro, M.; Aliberti, G.; Padovano, B.; Seregni, E.; Crippa, F.; Mira, M.; Negri, A.; Spreafico, C.; Morosi, C.; Civelli, E.; Lanocita, R.; Marchiano, A.; Romito, R.; Sposito, C.; Bhoori, S.; Facciorusso, A.; Mazzaferro, V.; Camerini, T.; Carrara, M.; Pellizzari, S.; Migliorisi, M.; De Nile, M.C.

    2015-01-01

    The aim of this study was to optimize the dosimetric approach and to review the absorbed doses delivered, taking into account radiobiology, in order to identify the optimal methodology for an individualized treatment planning strategy based on 99m Tc-macroaggregated albumin (MAA) single photon emission computed tomography (SPECT) images. We performed retrospective dosimetry of the standard TheraSphere registered treatment on 52 intermediate (n = 17) and advanced (i.e. portal vein thrombosis, n = 35) hepatocarcinoma patients with tumour burden < 50 % and without obstruction of the main portal vein trunk. Response was monitored with the densitometric radiological criterion (European Association for the Study of the Liver) and treatment-related liver decompensation was defined ad hoc with a time cut-off of 6 months. Adverse events clearly attributable to disease progression or other causes were not attributed to treatment. Voxel dosimetry was performed with the local deposition method on 99m Tc-MAA SPECT images. The reconstruction protocol was optimized. Concordance of 99m Tc-MAA and 90 Y bremsstrahlung microsphere biodistributions was studied in 35 sequential patients. Two segmentation methods were used, based on SPECT alone (home-made code) or on coregistered SPECT/CT images (IMALYTICS trademark by Philips). STRATOS trademark absorbed dose calculation was validated for 90 Y with a single time point. Radiobiology was used introducing other dosimetric variables besides the mean absorbed dose D: equivalent uniform dose (EUD), biologically effective dose averaged over voxel values (BED ave ) and equivalent uniform biologically effective dose (EUBED). Two sets of radiobiological parameters, the first derived from microsphere irradiation and the second from external beam radiotherapy (EBRT), were used. A total of 16 possible methodologies were compared. Tumour control probability (TCP) and normal tissue complication probability (NTCP) were derived. The area under the

  14. Country report: Syria. Development of {sup 90}Y/{sup 90}Sr Generator and {sup 90}Y Radiopharmaceuticals

    Energy Technology Data Exchange (ETDEWEB)

    Yassine, Taufik; Mukhallalati, Ch. Heyam, E-mail: atomic@aec.org.sy [Atomic Energy Commission of Syria, Damascus (Syrian Arab Republic)

    2010-07-01

    The aim of this project is to develop a technique for preparation of {sup 90}Sr-{sup 90}Y generator, we have developed a separation technique for isolation of {sup 90}Y from {sup 90}Sr based on using Sr – Spec resin packed in three columns for separation and purification of {sup 90}Sr-{sup 90}Y .The resulting Y90 is used for therapeutic applications. The first part of this project describe a prototype design for the {sup 90}Sr- {sup 90}Y generator in order to get a very accurate method to obtain the minimum possible {sup 90}Sr Breakthrough. 25 mci of {sup 90}Sr was used in the generator {sup 90}Sr-{sup 90}Y and we obtained the elution yield of {sup 90}Y higher than 88%, Also the eluate was used for preparation of several {sup 90}Y radiopharmaceuticals such as {sup 90}YEDTMP and {sup 90}Y-DOTA-HR{sub 3}. And the work is continues to investigate more radiopharmaceuticals applications in the second part of this project such as {sup 90}Y– FHMA. In this part of the co-coordination research programmer, A protocol based on results of this studies was developed to prepare and operate a higher activity generator (50-100mci), the resulting elution yield was approximately 94% of {sup 90}Y . The elute was used in preparation of new {sup 90}Y radiopharmaceuticals. The monoclonal antibodies is still evolving by conjugate Rituximab to The macrocyclic bifunctional chelating agent,(p-SCN-Bn-DOTA)S-2-(4-Isothiocyanatobenzyle)-1,4,7,10- tetraazacyclododecane-tetraaceticacid to obtain the inmunoconjugate DOTA-Rituximub in simple way and then investigating the radio labeling conditions with {sup 90}Y. (author)

  15. Occupational exposure following Yttrium-90 microspheres SIR therapy

    International Nuclear Information System (INIS)

    Fontaine, P.; Boirie, G.; Dieudonne, A.; Leguludec, D.; Lebtahi, R.; Ben Reguiga, M.

    2015-01-01

    Full text of publication follows. Introduction: Selective Internal Radiation Therapy (SIRT) is a promising technique for solid hepatic neoplasms treatment. SIRT consists in implanting radioactive microspheres (RMS) in targeted hepatic lesions via femoral artery. Two RMS-Therapsheres [glass-microspheres/TSR] and Sir-Spheres [resin-spheres/SSR]- are marketed in the European market, both radiolabeled with Yttrium-90. The objective of this study is to assess occupational exposure for nuclear medicine, radiology and clinical staff involved in Y 90 -RMS preparation and implantation. Materials and methods: The study was conducted on 20 patients treated for Hepato-Cellular Carcinoma: 10 treated with TSR and 10 with SSR. Dose rate (DR, mSv/h) or absorbed doses (mSv) measurements were made during all steps of TSR and SSR handling: sources receipt and unpacking, preparation, transport to radiology, implantation, and patient care. Measurements were made with portable ionization chamber(Babyline/Nardeux), spectrometer(FieldSpect/Aries), digital dosimeter (NED/Unfors) and operational dosimeter (Mk2/Siemens). Values were expressed as mean±SD. Results: patients received of 1.8 GBq to 3.1 GBq of TSR and 0.55 GBq to 2.4 GBq of SSR. TSR were delivered ready-to-use with the prescribed activity. For SSR only one activity was commercially available and shipped (3 GBq at calibration-time)requiring a preparation step to adjust needed activity. DR measured during RMS was 1723 ± 157 μSv/h SSR and 1189 ± 92 μSv/h for TSR. When preparing spheres in radiopharmacy, fingers and whole body doses were respectively 8326 ± 2360 μSv and 12.3 ± 5,2 μSv for Sir-Spheres vs. 33.5 ± 7.8 μSv and 1.1 ± 0.3 μSv for TSR. DR in contact with carrying case during RMS transfer to radiology were 299 ± 102 μSv/h for SSR and 5.3 ± 1.2 μSv/h for TSR. During RMS infusion, radiologist's finger doses were limited to 3.6 ± 1 μSv for SSR and 0.7± 0.3 μSv for TSR. Finally, following RMS

  16. A collimator optimization method for quantitative imaging: application to Y-90 bremsstrahlung SPECT.

    Science.gov (United States)

    Rong, Xing; Frey, Eric C

    2013-08-01

    Post-therapy quantitative 90Y bremsstrahlung single photon emission computed tomography (SPECT) has shown great potential to provide reliable activity estimates, which are essential for dose verification. Typically 90Y imaging is performed with high- or medium-energy collimators. However, the energy spectrum of 90Y bremsstrahlung photons is substantially different than typical for these collimators. In addition, dosimetry requires quantitative images, and collimators are not typically optimized for such tasks. Optimizing a collimator for 90Y imaging is both novel and potentially important. Conventional optimization methods are not appropriate for 90Y bremsstrahlung photons, which have a continuous and broad energy distribution. In this work, the authors developed a parallel-hole collimator optimization method for quantitative tasks that is particularly applicable to radionuclides with complex emission energy spectra. The authors applied the proposed method to develop an optimal collimator for quantitative 90Y bremsstrahlung SPECT in the context of microsphere radioembolization. To account for the effects of the collimator on both the bias and the variance of the activity estimates, the authors used the root mean squared error (RMSE) of the volume of interest activity estimates as the figure of merit (FOM). In the FOM, the bias due to the null space of the image formation process was taken in account. The RMSE was weighted by the inverse mass to reflect the application to dosimetry; for a different application, more relevant weighting could easily be adopted. The authors proposed a parameterization for the collimator that facilitates the incorporation of the important factors (geometric sensitivity, geometric resolution, and septal penetration fraction) determining collimator performance, while keeping the number of free parameters describing the collimator small (i.e., two parameters). To make the optimization results for quantitative 90Y bremsstrahlung SPECT more

  17. A gate evaluation of the sources of error in quantitative90 Y PET.

    Science.gov (United States)

    Strydhorst, Jared; Carlier, Thomas; Dieudonné, Arnaud; Conti, Maurizio; Buvat, Irène

    2016-10-01

    Accurate reconstruction of the dose delivered by 90 Y microspheres using a postembolization PET scan would permit the establishment of more accurate dose-response relationships for treatment of hepatocellular carcinoma with 90 Y. However, the quality of the PET data obtained is compromised by several factors, including poor count statistics and a very high random fraction. This work uses Monte Carlo simulations to investigate what impact factors other than low count statistics have on the quantification of 90 Y PET. PET acquisitions of two phantoms-a NEMA PET phantom and the NEMA IEC PET body phantom-containing either 90 Y or 18 F were simulated using gate. Simulated projections were created with subsets of the simulation data allowing the contributions of random, scatter, and LSO background to be independently evaluated. The simulated projections were reconstructed using the commercial software for the simulated scanner, and the quantitative accuracy of the reconstruction and the contrast recovery of the reconstructed images were evaluated. The quantitative accuracy of the 90 Y reconstructions were not strongly influenced by the high random fraction present in the projection data, and the activity concentration was recovered to within 5% of the known value. The contrast recovery measured for simulated 90 Y data was slightly poorer than that for simulated 18 F data with similar count statistics. However, the degradation was not strongly linked to any particular factor. Using a more restricted energy range to reduce the random fraction in the projections had no significant effect. Simulations of 90 Y PET confirm that quantitative 90 Y is achievable with the same approach as that used for 18 F, and that there is likely very little margin for improvement by attempting to model aspects unique to 90 Y, such as the much higher random fraction or the presence of bremsstrahlung in the singles data. © 2016 American Association of Physicists in Medicine.

  18. Radioembolization of hepatocarcinoma with {sup 90}Y glass microspheres: development of an individualized treatment planning strategy based on dosimetry and radiobiology

    Energy Technology Data Exchange (ETDEWEB)

    Chiesa, C.; Maccauro, M.; Aliberti, G.; Padovano, B.; Seregni, E.; Crippa, F. [Foundation IRCCS Istituto Nazionale Tumori, Nuclear Medicine Division, Milan (Italy); Mira, M.; Negri, A. [University of Milan, Postgraduate Health Physics School, Milan (Italy); Spreafico, C.; Morosi, C.; Civelli, E.; Lanocita, R.; Marchiano, A. [Foundation IRCCS Istituto Nazionale Tumori, Radiology 2, Milan (Italy); Romito, R.; Sposito, C.; Bhoori, S.; Facciorusso, A.; Mazzaferro, V. [Foundation IRCCS Istituto Nazionale Tumori, Surgery 1, Milan (Italy); Camerini, T. [Foundation IRCCS Istituto Nazionale Tumori, Scientific Direction, Milan (Italy); Carrara, M. [Foundation IRCCS Istituto Nazionale Tumori, Health Physics, Milan (Italy); Pellizzari, S. [University La Sapienza, Engineering Faculty, Rome (Italy); Migliorisi, M. [Foundation IRCCS Istituto Nazionale Tumori, Nuclear Medicine Division, Milan (Italy); Foundation IRCCS Istituto Nazionale Tumori, Clinical Engineering, Milan (Italy); De Nile, M.C. [University of Pavia, Physics Faculty, Pavia, Lombardy (Italy)

    2015-10-15

    The aim of this study was to optimize the dosimetric approach and to review the absorbed doses delivered, taking into account radiobiology, in order to identify the optimal methodology for an individualized treatment planning strategy based on {sup 99m}Tc-macroaggregated albumin (MAA) single photon emission computed tomography (SPECT) images. We performed retrospective dosimetry of the standard TheraSphere registered treatment on 52 intermediate (n = 17) and advanced (i.e. portal vein thrombosis, n = 35) hepatocarcinoma patients with tumour burden < 50 % and without obstruction of the main portal vein trunk. Response was monitored with the densitometric radiological criterion (European Association for the Study of the Liver) and treatment-related liver decompensation was defined ad hoc with a time cut-off of 6 months. Adverse events clearly attributable to disease progression or other causes were not attributed to treatment. Voxel dosimetry was performed with the local deposition method on {sup 99m}Tc-MAA SPECT images. The reconstruction protocol was optimized. Concordance of {sup 99m}Tc-MAA and {sup 90}Y bremsstrahlung microsphere biodistributions was studied in 35 sequential patients. Two segmentation methods were used, based on SPECT alone (home-made code) or on coregistered SPECT/CT images (IMALYTICS trademark by Philips). STRATOS trademark absorbed dose calculation was validated for {sup 90}Y with a single time point. Radiobiology was used introducing other dosimetric variables besides the mean absorbed dose D: equivalent uniform dose (EUD), biologically effective dose averaged over voxel values (BED{sub ave}) and equivalent uniform biologically effective dose (EUBED). Two sets of radiobiological parameters, the first derived from microsphere irradiation and the second from external beam radiotherapy (EBRT), were used. A total of 16 possible methodologies were compared. Tumour control probability (TCP) and normal tissue complication probability (NTCP) were

  19. Country report: Thailand. Development of Sr-90/ Y-90 Generator and Development of Radiopharmaceuticals Using Y-90

    International Nuclear Information System (INIS)

    Nipavan, Poramatikul

    2010-01-01

    The research project has been conducted at Thailand Institute of Nuclear Technology in accordance to the 1st RCM plan during the IAEA meeting in Warsaw. The objectives of the project include the following 5 specific aims: 1. Development of Sr-90/Y-90 ion-exchange chromatography generator 2. Development of Sr-90/Y-90 extraction chromatography generator 3. Development of quality control technique 4. Development of herapeutic radiopharmaceuticals Y-90 particulates/colloids 5. Development of Re-188 DMSA–bis-phosphonates Currently we have achieved specific aims 1 to 3. The specific aims 4 and 5 are during investigation. For specific aim 4, we are during the process to extract high purity 90 Y from 90 Sr/ 90 Y generator that will yield the starting 90 Y for the production of Y-90 particulates and colloids. For the 5 th specific aim, we are on hold to receive the starting agent, bis- Phosphonates, from Dr. Blower group. Therefore, this progress report will cover our work focusing on specific aims 1 to 3

  20. Country report: Thailand. Development of Sr-90/ Y-90 Generator and Development of Radiopharmaceuticals Using Y-90

    Energy Technology Data Exchange (ETDEWEB)

    Nipavan, Poramatikul [Nuclear Research and Development Group, Thailand Institute of Nuclear Technology (Public Organization), Bangkok (Thailand)

    2010-07-01

    The research project has been conducted at Thailand Institute of Nuclear Technology in accordance to the 1st RCM plan during the IAEA meeting in Warsaw. The objectives of the project include the following 5 specific aims: 1. Development of Sr-90/Y-90 ion-exchange chromatography generator 2. Development of Sr-90/Y-90 extraction chromatography generator 3. Development of quality control technique 4. Development of herapeutic radiopharmaceuticals Y-90 particulates/colloids 5. Development of Re-188 DMSA–bis-phosphonates Currently we have achieved specific aims 1 to 3. The specific aims 4 and 5 are during investigation. For specific aim 4, we are during the process to extract high purity {sup 90}Y from {sup 90}Sr/{sup 90}Y generator that will yield the starting {sup 90}Y for the production of Y-90 particulates and colloids. For the 5{sup th} specific aim, we are on hold to receive the starting agent, bis- Phosphonates, from Dr. Blower group. Therefore, this progress report will cover our work focusing on specific aims 1 to 3.

  1. Y-90 microshperes in the treatment of unresectable hepatocellular carcinoma.

    Science.gov (United States)

    Al-Kalbani, Abdullah; Kamel, Yasser

    2008-04-01

    A small percentage of patients with hepatocellular carcinoma (HCC) are candidates for curative treatment in form of resection or transplantation. There are different treatment options for unresectable HCC-like local ablative therapies and recently systemic therapy with Sorafenib. All of these have variable response rate and had been proven to improve survival. In the last few years, there is a growing interest in TheraSphere radioembolization. It consists of yttrium90 (Y-90) embedded into nonbiodegradable glass microspheres. It is selectively administered by intraarterial hepatic injection giving high doses of radiation to the tumor and sparing the liver parenchyma. It has been shown to improve survival and used as a bridge to transplantation and to downstage tumors for resection. Therasphere seems to have favorable safety profile and has been used in patients with portal vein thrombosis with successful outcome.

  2. Development of an electrochemical 90Sr-90Y generator for separation of 90Y suitable for targeted therapy

    International Nuclear Information System (INIS)

    Chakravarty, Rubel; Pandey, Usha; Manolkar, Remani B.; Dash, Ashutosh; Venkatesh, Meera; Pillai, M.R. Ambikalmajan

    2008-01-01

    90 Y of high specific activity and very high radionuclidic purity (>99.998%) is essential for targeted therapy. Since the current methods used for the preparation of 90 Y from 90 Sr are not adaptable for use in a central/hospital radiopharmacy, a simple 90 Sr- 90 Y generator system based on electrochemical separation technique was developed. Methods: Two-cycle electrolysis procedure was developed for separation of 90 Y from 90 Sr in nitrate solution. The first electrolysis was performed for 90 min in 90 Sr(NO 3 ) 2 feed solution at pH 2-3 at a potential of -2.5V with 100-200 mA current using platinum electrodes. The second electrolysis was performed for 45 min in 3 mM HNO 3 at a potential of -2.5V with 100 mA current. In this step, the cathode from the first electrolysis containing 90 Y was used as anode along with a fresh circular platinum electrode as cathode. The 90 Y deposited on the circular cathode after the second electrolysis was dissolved in acetate buffer to obtain 90 Y acetate, suitable for radiolabeling. Results: >96% recovery of 90 Y could be achieved in each cycle, with an overall decay corrected yield of >90%. The recovered 90 Y had high radionuclidic purity with barely 30.2±15.2 kBq (817±411 nCi) of 90 Sr per 37 GBq (1 Ci) of 90 Y (0.817±0.411 ppm). Consistent and repeated separation could be demonstrated using up to 1.85 GBq (50 mCi) of 90 Sr. The generator was named 'Kamadhenu,' the eternally milk-yielding Indian mythological cow. Conclusions: A technique suitable for adaptation at central radiopharmacies for obtaining therapeutic quantities of pure 90 Y has been developed

  3. Boosted selective internal radiation therapy with {sup 90}Y-loaded glass microspheres (B-SIRT) for hepatocellular carcinoma patients: a new personalized promising concept

    Energy Technology Data Exchange (ETDEWEB)

    Garin, E.; Lenoir, L. [Comprehensive Cancer Center, Institute Eugene Marquis, Department of Nuclear Medicine, CS 44229, Rennes (France); University of Rennes 1, Rennes (France); INSERM, U-991, Liver Metabolisms and Cancer, Rennes (France); Edeline, J. [University of Rennes 1, Rennes (France); Comprehensive Cancer Center, Institute Eugene Marquis, Department of Medical Oncology, CS 44229, Rennes (France); Laffont, S. [Comprehensive Cancer Center, Institute Eugene Marquis, Department of Nuclear Medicine, CS 44229, Rennes (France); Mesbah, H.; Poree, P. [Comprehensive Cancer Center, Institute Eugene Marquis, Department of Medical Informatics, CS 44229, Rennes (France); Sulpice, L. [INSERM, U-991, Liver Metabolisms and Cancer, Rennes (France); Centre Hospitalier Universitaire Pontchaillou, Department of Digestive Surgery, Rennes (France); Boudjema, K. [University of Rennes 1, Rennes (France); INSERM, U-991, Liver Metabolisms and Cancer, Rennes (France); Centre Hospitalier Universitaire Pontchaillou, Department of Digestive Surgery, Rennes (France); Mesbah, M. [University of Pierre et Marie Curie, Paris (France); Guillygomarc' h, A. [Centre Hospitalier Universitaire Pontchaillou, Department of Hepatology, Rennes (France); Quehen, E. [Centre Hospitalier Universitaire Pontchaillou, Department of Radiology, Rennes (France); Pracht, M. [Comprehensive Cancer Center, Institute Eugene Marquis, Department of Medical Oncology, CS 44229, Rennes (France); Raoul, J.L. [Comprehensive Cancer Center, Institute Paoli Calmette, Department of Medical Oncology, Marseille (France); Clement, B. [INSERM, U-991, Liver Metabolisms and Cancer, Rennes (France); Rolland, Y. [Comprehensive Cancer Center, Institute Eugene Marquis, Department of Medical Imaging, CS 44229, Rennes (France); Boucher, E. [INSERM, U-991, Liver Metabolisms and Cancer, Rennes (France); Comprehensive Cancer Center, Institute Eugene Marquis, Department of Medical Oncology, CS 44229, Rennes (France)

    2013-07-15

    To evaluate the impact of dosimetry based on MAA SPECT/CT for the prediction of response, toxicity and survival, and for treatment planning in patients with hepatocellular carcinoma (HCC) treated with {sup 90}Y-loaded glass microspheres (TheraSphere registered). TheraSphere registered was administered to 71 patients with inoperable HCC. MAA SPECT/CT quantitative analysis was used for the calculation of the tumour dose (TD), healthy injected liver dose (HILD), and total injected liver dose. Response was evaluated at 3 months using EASL criteria. Time to progression (TTP) and overall survival (OS) were evaluated using the Kaplan-Meier method. Factors potentially associated with liver toxicity were combined to construct a liver toxicity score (LTS). The response rate was 78.8 %. Median TD were 342 Gy for responding lesions and 191 Gy for nonresponding lesions (p < 0.001). With a threshold TD of 205 Gy, MAA SPECT/CT predicted response with a sensitivity of 100 % and overall accuracy of 90 %. Based on TD and HILD, 17 patients underwent treatment intensification resulting in a good response rate (76.4 %), without increased grade III liver toxicity. The median TTP and OS were 5.5 months (2-9.5 months) and 11.5 months (2-31 months), respectively, in patients with TD <205 Gy and 13 months (10-16 months) and 23.2 months (17.5-28.5 months), respectively, in those with TD >205 Gy (p = 0.0015 and not significant). Among patients with portal vein thrombosis (PVT) (n = 33), the median TTP and OS were 4.5 months (2-7 months) and 5 months (2-8 months), respectively, in patients with TD <205 Gy and 10 months (6-15.2 months) and 21.5 months (12-28.5 months), respectively, in those with TD >205 Gy (p = 0.039 and 0.005). The median OS was 24.5 months (18-28.5 months) in PVT patients with TD >205 Gy and good PVT targeting on MAA SPECT/CT. The LTS was able to detect severe liver toxicity (n = 6) with a sensitivity of 83 % and overall accuracy of 97 %. Dosimetry based on MAA SPECT/CT was

  4. Development of 90Sr-90Y generators

    International Nuclear Information System (INIS)

    Barrio, Graciela

    2007-01-01

    Yttrium-90 is a radioisotope of great interest in the field of Nuclear Medicine. It is considered one of the most important and most used radionuclides for radioimmunotherapeutical applications, especially promising for the treatment of certain types of cancer. Another important application of 90 Y is radio synovectomy. This radionuclide has a half-life of 64 hours, emits long range beta particles (maximum energy of 2.3 MeV) and decays, without intermediate nuclides, to a stable daughter. 90 Y may be obtained carrier-free, generated by the decay of its parent 90 Sr (half-life=28 years). 90 Sr is a product from uranium fission, and due to its long half-life, can be indefinitely used, which is certainly advantageous. It is present in great amounts, and needs to be processed and purified in order to be used as raw material for the generators. Generators of 90 Sr- 90 Y may thus be used during various months, due to 90 Sr long half-life. Several methods for the separation of 90 Y from 90 Sr by solvent extraction and ion exchange have been reported in literature. Thanks to its simplicity, ion exchange techniques have been more commonly used for this generator system. The main objective of this work was to develop a methodology for the preparation of 90 Sr- 90 Y generators, using cationic exchange resins. In such method, 90 Sr is strongly adsorbed in the resin and 90 Y is eluted by a 0.003 M EDTA solution. According to the quality control carried out, results showed that elution yields are greater than 65%, thus confirming the efficiency of the separation method used.

  5. Absorbed dose kernel and self-shielding calculations for a novel radiopaque glass microsphere for transarterial radioembolization.

    Science.gov (United States)

    Church, Cody; Mawko, George; Archambault, John Paul; Lewandowski, Robert; Liu, David; Kehoe, Sharon; Boyd, Daniel; Abraham, Robert; Syme, Alasdair

    2018-02-01

    Radiopaque microspheres may provide intraprocedural and postprocedural feedback during transarterial radioembolization (TARE). Furthermore, the potential to use higher resolution x-ray imaging techniques as opposed to nuclear medicine imaging suggests that significant improvements in the accuracy and precision of radiation dosimetry calculations could be realized for this type of therapy. This study investigates the absorbed dose kernel for novel radiopaque microspheres including contributions of both short and long-lived contaminant radionuclides while concurrently quantifying the self-shielding of the glass network. Monte Carlo simulations using EGSnrc were performed to determine the dose kernels for all monoenergetic electron emissions and all beta spectra for radionuclides reported in a neutron activation study of the microspheres. Simulations were benchmarked against an accepted 90 Y dose point kernel. Self-shielding was quantified for the microspheres by simulating an isotropically emitting, uniformly distributed source, in glass and in water. The ratio of the absorbed doses was scored as a function of distance from a microsphere. The absorbed dose kernel for the microspheres was calculated for (a) two bead formulations following (b) two different durations of neutron activation, at (c) various time points following activation. Self-shielding varies with time postremoval from the reactor. At early time points, it is less pronounced due to the higher energies of the emissions. It is on the order of 0.4-2.8% at a radial distance of 5.43 mm with increased size from 10 to 50 μm in diameter during the time that the microspheres would be administered to a patient. At long time points, self-shielding is more pronounced and can reach values in excess of 20% near the end of the range of the emissions. Absorbed dose kernels for 90 Y, 90m Y, 85m Sr, 85 Sr, 87m Sr, 89 Sr, 70 Ga, 72 Ga, and 31 Si are presented and used to determine an overall kernel for the

  6. A GATE evaluation of the sources of error in quantitative {sup 90}Y PET

    Energy Technology Data Exchange (ETDEWEB)

    Strydhorst, Jared, E-mail: jared.strydhorst@gmail.com; Buvat, Irène [IMIV, U1023 Inserm/CEA/Université Paris-Sud and ERL 9218 CNRS, Université Paris-Saclay, CEA/SHFJ, Orsay 91401 (France); Carlier, Thomas [Department of Nuclear Medicine, Centre Hospitalier Universitaire de Nantes and CRCNA, Inserm U892, Nantes 44000 (France); Dieudonné, Arnaud [Department of Nuclear Medicine, Hôpital Beaujon, HUPNVS, APHP and Inserm U1149, Clichy 92110 (France); Conti, Maurizio [Siemens Healthcare Molecular Imaging, Knoxville, Tennessee, 37932 (United States)

    2016-10-15

    Purpose: Accurate reconstruction of the dose delivered by {sup 90}Y microspheres using a postembolization PET scan would permit the establishment of more accurate dose–response relationships for treatment of hepatocellular carcinoma with {sup 90}Y. However, the quality of the PET data obtained is compromised by several factors, including poor count statistics and a very high random fraction. This work uses Monte Carlo simulations to investigate what impact factors other than low count statistics have on the quantification of {sup 90}Y PET. Methods: PET acquisitions of two phantoms—a NEMA PET phantom and the NEMA IEC PET body phantom-containing either {sup 90}Y or {sup 18}F were simulated using GATE. Simulated projections were created with subsets of the simulation data allowing the contributions of random, scatter, and LSO background to be independently evaluated. The simulated projections were reconstructed using the commercial software for the simulated scanner, and the quantitative accuracy of the reconstruction and the contrast recovery of the reconstructed images were evaluated. Results: The quantitative accuracy of the {sup 90}Y reconstructions were not strongly influenced by the high random fraction present in the projection data, and the activity concentration was recovered to within 5% of the known value. The contrast recovery measured for simulated {sup 90}Y data was slightly poorer than that for simulated {sup 18}F data with similar count statistics. However, the degradation was not strongly linked to any particular factor. Using a more restricted energy range to reduce the random fraction in the projections had no significant effect. Conclusions: Simulations of {sup 90}Y PET confirm that quantitative {sup 90}Y is achievable with the same approach as that used for {sup 18}F, and that there is likely very little margin for improvement by attempting to model aspects unique to {sup 90}Y, such as the much higher random fraction or the presence of

  7. First experience of hepatic radioembolization using microspheres labelled with yttrium-90 (TheraSphere): practical aspects concerning its implementation

    International Nuclear Information System (INIS)

    Garin, Etienne; Bourguet, Patrick; Rolland, Yan; Boucher, Eveline; Ardisson, Valerie; Laffont, Sophie; Boudjema, Karim; Raoul, Jean-Luc

    2010-01-01

    We report a first experience involving the use of 90 Y radiolabelled microspheres (TheraSphere) for the treatment of mainly primary hepatic tumours. Treatment using TheraSphere microspheres was planned in 15 patients (13 with hepatocellular carcinoma, 2 with neuroendocrine tumour metastases). The treatment was preceded by a first angiography aimed at embolizing the vascularizing arterial branches of other structures outside the liver and evaluating the percentage of pulmonary shunt by scintiscanning after perfusion with 99m Tc-MAA. The objective of the treatment carried out during a second angiography was to deliver a dose of 120±20 Gy (mean±SD) to the target hepatic volume. Technical difficulties were encountered in embolizing gastroduodenal or gastric branches in two patients and in one patient these led to cancellation of the treatment. A total of 14 patients were treated with an average activity of 3.18 GBq. In one patient, the injection was defective (stagnation of microspheres at the outlet of the catheter). SPECT/CT acquisitions provided important information in four patients (visualization of the gallbladder in three; visualization of the stomach in one, leading to a new coiling). The average exposure of the nuclear medicine physician carrying out the injections was 64±80μSv at the fingers. A partial response was seen in six patients, stabilization in five and progression in three. One patient presented with a gastric ulcer and two showed an increase in their hepatocellular insufficiency. Although sometimes technically difficult, the use of TheraSphere microspheres is a worthwhile therapeutic approach because of the low level exposure of operators and the encouraging rate of response or stabilization. The use of SPECT/CT contributes greatly to helping therapeutic planning, especially in the learning curve or when the angiographic procedure is difficult. (orig.)

  8. First experience of hepatic radioembolization using microspheres labelled with yttrium-90 (TheraSphere): practical aspects concerning its implementation.

    Science.gov (United States)

    Garin, Etienne; Rolland, Yan; Boucher, Eveline; Ardisson, Valérie; Laffont, Sophie; Boudjema, Karim; Bourguet, Patrick; Raoul, Jean-Luc

    2010-03-01

    We report a first experience involving the use of (90)Y radiolabelled microspheres (TheraSphere) for the treatment of mainly primary hepatic tumours. Treatment using TheraSphere microspheres was planned in 15 patients (13 with hepatocellular carcinoma, 2 with neuroendocrine tumour metastases). The treatment was preceded by a first angiography aimed at embolizing the vascularizing arterial branches of other structures outside the liver and evaluating the percentage of pulmonary shunt by scintiscanning after perfusion with (99m)Tc-MAA. The objective of the treatment carried out during a second angiography was to deliver a dose of 120+/-20 Gy (mean+/-SD) to the target hepatic volume. Technical difficulties were encountered in embolizing gastroduodenal or gastric branches in two patients and in one patient these led to cancellation of the treatment. A total of 14 patients were treated with an average activity of 3.18 GBq. In one patient, the injection was defective (stagnation of microspheres at the outlet of the catheter). SPECT/CT acquisitions provided important information in four patients (visualization of the gallbladder in three; visualization of the stomach in one, leading to a new coiling). The average exposure of the nuclear medicine physician carrying out the injections was 64+/-80 microSv at the fingers. A partial response was seen in six patients, stabilization in five and progression in three. One patient presented with a gastric ulcer and two showed an increase in their hepatocellular insufficiency. Although sometimes technically difficult, the use of TheraSphere microspheres is a worthwhile therapeutic approach because of the low level exposure of operators and the encouraging rate of response or stabilization. The use of SPECT/CT contributes greatly to helping therapeutic planning, especially in the learning curve or when the angiographic procedure is difficult.

  9. First experience of hepatic radioembolization using microspheres labelled with yttrium-90 (TheraSphere): practical aspects concerning its implementation

    Energy Technology Data Exchange (ETDEWEB)

    Garin, Etienne; Bourguet, Patrick [Comprehensive Cancer Center Eugene Marquis, Department of Nuclear Medicine, Rennes (France); University of Rennes 1, European University of Brittany/EA MDC, Rennes (France); Rolland, Yan [Comprehensive Cancer Center Eugene Marquis, Department of Medical Imaging, Rennes (France); Boucher, Eveline [Comprehensive Cancer Center Eugene Marquis, Department of Medical Oncology, Rennes (France); Ardisson, Valerie; Laffont, Sophie [Comprehensive Cancer Center Eugene Marquis, Department of Nuclear Medicine, Rennes (France); Boudjema, Karim [University of Rennes 1, European University of Brittany/EA MDC, Rennes (France); CHU Pontchaillou, Department of Digestive Surgery, Rennes (France); Raoul, Jean-Luc [University of Rennes 1, European University of Brittany/EA MDC, Rennes (France); Comprehensive Cancer Center Eugene Marquis, Department of Medical Oncology, Rennes (France)

    2010-03-15

    We report a first experience involving the use of {sup 90}Y radiolabelled microspheres (TheraSphere) for the treatment of mainly primary hepatic tumours. Treatment using TheraSphere microspheres was planned in 15 patients (13 with hepatocellular carcinoma, 2 with neuroendocrine tumour metastases). The treatment was preceded by a first angiography aimed at embolizing the vascularizing arterial branches of other structures outside the liver and evaluating the percentage of pulmonary shunt by scintiscanning after perfusion with {sup 99m}Tc-MAA. The objective of the treatment carried out during a second angiography was to deliver a dose of 120{+-}20 Gy (mean{+-}SD) to the target hepatic volume. Technical difficulties were encountered in embolizing gastroduodenal or gastric branches in two patients and in one patient these led to cancellation of the treatment. A total of 14 patients were treated with an average activity of 3.18 GBq. In one patient, the injection was defective (stagnation of microspheres at the outlet of the catheter). SPECT/CT acquisitions provided important information in four patients (visualization of the gallbladder in three; visualization of the stomach in one, leading to a new coiling). The average exposure of the nuclear medicine physician carrying out the injections was 64{+-}80{mu}Sv at the fingers. A partial response was seen in six patients, stabilization in five and progression in three. One patient presented with a gastric ulcer and two showed an increase in their hepatocellular insufficiency. Although sometimes technically difficult, the use of TheraSphere microspheres is a worthwhile therapeutic approach because of the low level exposure of operators and the encouraging rate of response or stabilization. The use of SPECT/CT contributes greatly to helping therapeutic planning, especially in the learning curve or when the angiographic procedure is difficult. (orig.)

  10. Development of {sup 90}Sr-{sup 90}Y generators; Desenvolvimento de geradores de {sup 90}Sr-{sup 90}Y

    Energy Technology Data Exchange (ETDEWEB)

    Barrio, Graciela, E-mail: gracielabarrio@gmail.co [Pontificia Univ. Catolica de Sao Paulo (PUC-SP), SP (Brazil). Dept. de Fisica; Osso Junior, Joao Alberto, E-mail: jaossoj@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2007-07-01

    Yttrium-90 is a radioisotope of great interest in the field of Nuclear Medicine. It is considered one of the most important and most used radionuclides for radioimmunotherapeutical applications, especially promising for the treatment of certain types of cancer. Another important application of {sup 90}Y is radio synovectomy. This radionuclide has a half-life of 64 hours, emits long range beta particles (maximum energy of 2.3 MeV) and decays, without intermediate nuclides, to a stable daughter. {sup 90}Y may be obtained carrier-free, generated by the decay of its parent {sup 90}Sr (half-life=28 years). {sup 90}Sr is a product from uranium fission, and due to its long half-life, can be indefinitely used, which is certainly advantageous. It is present in great amounts, and needs to be processed and purified in order to be used as raw material for the generators. Generators of {sup 90}Sr-{sup 90}Y may thus be used during various months, due to {sup 90}Sr long half-life. Several methods for the separation of {sup 90}Y from {sup 90}Sr by solvent extraction and ion exchange have been reported in literature. Thanks to its simplicity, ion exchange techniques have been more commonly used for this generator system. The main objective of this work was to develop a methodology for the preparation of {sup 90}Sr-{sup 90}Y generators, using cationic exchange resins. In such method, {sup 90}Sr is strongly adsorbed in the resin and {sup 90}Y is eluted by a 0.003 M EDTA solution. According to the quality control carried out, results showed that elution yields are greater than 65%, thus confirming the efficiency of the separation method used.

  11. Improved quantitative 90 Y bremsstrahlung SPECT/CT reconstruction with Monte Carlo scatter modeling.

    Science.gov (United States)

    Dewaraja, Yuni K; Chun, Se Young; Srinivasa, Ravi N; Kaza, Ravi K; Cuneo, Kyle C; Majdalany, Bill S; Novelli, Paula M; Ljungberg, Michael; Fessler, Jeffrey A

    2017-12-01

    In 90 Y microsphere radioembolization (RE), accurate post-therapy imaging-based dosimetry is important for establishing absorbed dose versus outcome relationships for developing future treatment planning strategies. Additionally, accurately assessing microsphere distributions is important because of concerns for unexpected activity deposition outside the liver. Quantitative 90 Y imaging by either SPECT or PET is challenging. In 90 Y SPECT model based methods are necessary for scatter correction because energy window-based methods are not feasible with the continuous bremsstrahlung energy spectrum. The objective of this work was to implement and evaluate a scatter estimation method for accurate 90 Y bremsstrahlung SPECT/CT imaging. Since a fully Monte Carlo (MC) approach to 90 Y SPECT reconstruction is computationally very demanding, in the present study the scatter estimate generated by a MC simulator was combined with an analytical projector in the 3D OS-EM reconstruction model. A single window (105 to 195-keV) was used for both the acquisition and the projector modeling. A liver/lung torso phantom with intrahepatic lesions and low-uptake extrahepatic objects was imaged to evaluate SPECT/CT reconstruction without and with scatter correction. Clinical application was demonstrated by applying the reconstruction approach to five patients treated with RE to determine lesion and normal liver activity concentrations using a (liver) relative calibration. There was convergence of the scatter estimate after just two updates, greatly reducing computational requirements. In the phantom study, compared with reconstruction without scatter correction, with MC scatter modeling there was substantial improvement in activity recovery in intrahepatic lesions (from > 55% to > 86%), normal liver (from 113% to 104%), and lungs (from 227% to 104%) with only a small degradation in noise (13% vs. 17%). Similarly, with scatter modeling contrast improved substantially both visually and in

  12. Quantitative and Qualitative Assessment of Yttrium-90 PET/CT Imaging

    OpenAIRE

    Attarwala, Ali Asgar; Molina-Duran, Flavia; Büsing, Karen-Anett; Schönberg, Stefan O.; Bailey, Dale L.; Willowson, Kathy; Glatting, Gerhard

    2014-01-01

    Yttrium-90 is known to have a low positron emission decay of 32 ppm that may allow for personalized dosimetry of liver cancer therapy with (90)Y labeled microspheres. The aim of this work was to image and quantify (90)Y so that accurate predictions of the absorbed dose can be made. The measurements were performed within the QUEST study (University of Sydney, and Sirtex Medical, Australia). A NEMA IEC body phantom containing 6 fillable spheres (10-37 mm ∅) was used to measure the 90Y distribut...

  13. radio embolization of yttrium 90 glass microspheres in treatment of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    El Fouly, A.H.A.

    2010-01-01

    Hepatocellular carcinoma (HCC) is a common cancer that typically occurs in the setting of cirrhosis and chronic hepatitis virus infections. HCC is considered currently as global problem; its incidence is expected to increase dramatically by the next few decades. More than 90 % of the accidentally diagnosed patients have non resectable tumor. Portal vein thrombosis, diffuse multifocal liver infiltration and large tumor burden are considered to be a great obstacle in front of the modern lines of treatment, even with Child A liver cirrhosis. Transarterial intrahepatic application of Yttrium-90 glass microspheres may allow effective local ablative treatment of patients with intrahepatic advanced hepatocellular carcinoma (HCC) with or without portal vein thrombosis. The aim of this open-label phase II study was to validate evidence on the safety and efficacy of this treatment in an European cohort of patients with locally advanced HCC such as (large tumor burden, multifocal distribution, portal vein thrombosis). And to assess the response rate according to different approved response assessment guidelines (WHO, RECIST and EASL). Patients and Methods Starting from November 2006 till March 2009, one hundred and eight advanced unresectable HCC patients with and without portal vein thrombosis were included in this prospective study. Yttrium-90 microspheres radiotherapy was performed in a lobar fashion through the right or left hepatic artery. In bilobar disease, right and left liver lobe were treated with 4-6 weeks intervals in between. Response rate was assessed according to different international response assessment criteria (WHO, RECIST and EASL) with sequential computed tomography scans till the last clinical visit or death. The safety of this technique was assessed according to the Common Toxicity Criteria version 3

  14. Development of techniques for rapid analysis of 90Sr breakthrough and 90Y activity from a 90Sr-90Y generator

    International Nuclear Information System (INIS)

    Chism, S.E.; Goodwin, D.A.; Meares, C.F.

    1986-01-01

    Recently there has been interest in labelling monoclonal antibodies with therapeutic amounts of a pure beta emitting isotope. 90 Y offers many desirable features and may be conveniently and economically obtained from a 90 Sr- 90 Y generator. A potential hazard with this system is breakthrough of the parent 90 Sr which has a half life of 28 years and is an extremely toxic bone seeking isotope. Therefore it is essential that the daughter be completely separated from its parent. We have devised two simple techniques which allow us to monitor rapidly the amount of 90 Sr breakthrough and quantitate the 90 Y activity over a 5 log range. (author)

  15. Use of Yttrium-90 glass microspheres (TheraSphere) for the treatment of unresectable hepatocellular carcinoma in patients with portal vein thrombosis.

    Science.gov (United States)

    Salem, Riad; Lewandowski, Robert; Roberts, Carol; Goin, James; Thurston, Kenneth; Abouljoud, Marwan; Courtney, Angi

    2004-04-01

    Intra-arterial injection of Yttrium-90 glass microspheres ((90)Y- microS; TheraSphere, MDS Nordion, Ottawa, Canada) is indicated for treatment of unresectable hepatocellular carcinoma (HCC) in the presence of acceptable liver function. This study presents hepatic toxicity results after unilobar and bilobar intra-arterial administration of (90)Y- microS in patients with unresectable HCC who had known portal vein thrombosis (PVT) without evidence of cavernous transformation. Fifteen patients with unresectable HCC and PVT of one or both first order and related segmental portal venous branches received a total of 29 infusions of (90)Y- microS for treatment of HCC. All patients had pretreatment evaluation including: computed tomography (CT) imaging, alpha-fetoprotein (AFP) levels, liver function tests, technetium-99m macroaggregated albumin ((99)Tc-MAA) scan for evaluation of lung and visceral shunting, and angiography with visualization into the portal venous phase. (90)Y- micro S dose was based on lobar hepatic volume with adjustment for lung shunt activity. Liver toxicity was assessed by serum total bilirubin graded for severity according to the NIH NCI Clinical Toxicity Criteria (CTC version 2.0). Other adverse events were reported according to the standards established by the Society of Interventional Radiology. There were no procedural complications with delivery of (90)Y- microS, and treatment was well tolerated by all patients. Increased post-treatment bilirubin levels were observed across all treatments in five patients, four of whom had CT or AFP evidence of intrahepatic disease progression. After initial treatment, two patients developed bilirubin toxicity (grades 1 and 2); one patient demonstrated an increment in bilirubin toxicity grade (grade 1 to grade 3) and one patient had an improvement in grade after initial treatment. There were no new treatment-related toxicities in nine patients after a second treatment. (90)Y- microS treatment was well tolerated

  16. Progress of 90Y generator preparation

    International Nuclear Information System (INIS)

    Yin Bangshun; Li Mingqi; Deng Qimin; Cheng Zuoyong

    2009-01-01

    90 Y is an important radionuclide in radioimmunotherapy. The medical 90 Y is mainly obtained from 90 Y generator through methods of precipitation,coprecipitation, electrodeposition, solvent extraction, chromatography and so on. The progress of 90 Y generator, the advantages and disadvantages of different types of 90 Y generator, and the tendency of 90 Y generator preparation were described respectively. Comprehensive analysis showed that inorganic ion-exchange chromatography will be the main tendency of future 90 Y generator preparation. (authors)

  17. Clinical evaluation of the partition model for estimating radiation doses from yttrium-90 microspheres in the treatment of hepatic cancer

    International Nuclear Information System (INIS)

    Ho, S.; Lau, W.Y.; Leung, T.W.T.; Chan, M.; Johnson, P.J.; Li, A.K.C.

    1997-01-01

    Radiation doses to the tumour and non-tumorous liver compartments from yttrium-90 microspheres in the treatment of hepatic cancer, as estimated by a partition model, have been verified by correlation with the actual doses measured with a beta probe at open surgery. The validity of the doses to the lungs, the tumour and non-tumours liver compartment as estimated by the partition model was further evaluated in clinical settings. On the basis of the observation that one of three patients who received more than 30 Gy from a single treatment and one of two patients who received more than 50 Gy from multiple treatments developed radiation pneumonitis, it was deduced that an estimated lung dose 30 Gy as estimated by the partition model and were predicted to develop radiation pneumonitis, did so despite the use of partial hepatic embolization to reduce the degree of lung shunting. Furthermore, a higher radiological response rate and prolonged survival were found in the group of patients who received higher tumour doses, as estimated by the partition model, than in the group with lower estimated tumour doses. Thus the radiation doses estimated by the partition model can be used to predict (a) complication rate, (b) response rate and (c) duration of survival in the same manner as the actual radiation doses measured with a beta probe at open surgery. The partition model has made selective internal radiation therapy using 90 Y microspheres safe and repeatable without laparotomy. (orig.)

  18. Hanford isotope project strategic business analysis yttrium-90 (Y-90)

    International Nuclear Information System (INIS)

    1995-10-01

    The purpose of this analysis is to address the short-term direction for the Hanford yttrium-90 (Y-90) project. Hanford is the sole DOE producer of Y-90, and is the largest repository for its source in this country. The production of Y-90 is part of the DOE Isotope Production and Distribution (IP and D) mission. The Y-90 is ''milked'' from strontium-90 (Sr-90), a byproduct of the previous Hanford missions. The use of Sr-90 to produce Y-90 could help reduce the amount of waste material processed and the related costs incurred by the clean-up mission, while providing medical and economic benefits. The cost of producing Y-90 is being subsidized by DOE-IP and D due to its use for research, and resultant low production level. It is possible that the sales of Y-90 could produce full cost recovery within two to three years, at two curies per week. Preliminary projections place the demand at between 20,000 and 50,000 curies per year within the next ten years, assuming FDA approval of one or more of the current therapies now in clinical trials. This level of production would incentivize private firms to commercialize the operation, and allow the government to recover some of its sunk costs. There are a number of potential barriers to the success of the Y-90 project, outside the control of the Hanford Site. The key issues include: efficacy, Food and Drug Administration (FDA) approval and medical community acceptance. There are at least three other sources for Y-90 available to the US users, but they appear to have limited resources to produce the isotope. Several companies have communicated interest in entering into agreements with Hanford for the processing and distribution of Y-90, including some of the major pharmaceutical firms in this country

  19. Hanford isotope project strategic business analysis yttrium-90 (Y-90)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-10-01

    The purpose of this analysis is to address the short-term direction for the Hanford yttrium-90 (Y-90) project. Hanford is the sole DOE producer of Y-90, and is the largest repository for its source in this country. The production of Y-90 is part of the DOE Isotope Production and Distribution (IP and D) mission. The Y-90 is ``milked`` from strontium-90 (Sr-90), a byproduct of the previous Hanford missions. The use of Sr-90 to produce Y-90 could help reduce the amount of waste material processed and the related costs incurred by the clean-up mission, while providing medical and economic benefits. The cost of producing Y-90 is being subsidized by DOE-IP and D due to its use for research, and resultant low production level. It is possible that the sales of Y-90 could produce full cost recovery within two to three years, at two curies per week. Preliminary projections place the demand at between 20,000 and 50,000 curies per year within the next ten years, assuming FDA approval of one or more of the current therapies now in clinical trials. This level of production would incentivize private firms to commercialize the operation, and allow the government to recover some of its sunk costs. There are a number of potential barriers to the success of the Y-90 project, outside the control of the Hanford Site. The key issues include: efficacy, Food and Drug Administration (FDA) approval and medical community acceptance. There are at least three other sources for Y-90 available to the US users, but they appear to have limited resources to produce the isotope. Several companies have communicated interest in entering into agreements with Hanford for the processing and distribution of Y-90, including some of the major pharmaceutical firms in this country.

  20. Phase transformation, morphology evolution and luminescence property variation in Y2O3: Eu hollow microspheres

    International Nuclear Information System (INIS)

    Wang, Qin; Guo, Jing; Jia, Wenjing; Liu, Baocang; Zhang, Jun

    2012-01-01

    Highlights: ► We report a general and facile method for the synthesis of Y 2 O 3 : Eu hollow microspheres. ► This method may be of great significance in the synthesis of many other hollow spherical materials. ► Phase, morphology and luminescence property were found to be strongly dependent on temperature and pH. ► The evolution process under various temperatures and pH values were discussed. ► The sample shows a strong red emission under short UV irradiation, and the lifetime is determined to be 7.0 ms. - Abstract: Y 2 O 3 : Eu hollow microspheres with average size of 500–600 nm have been successfully synthesized via a solvothermal method in the presence of sodium citrate as surfactant followed by a subsequent heat treatment process. High polymer F127(EO 106 PO 70 EO 106 ) served as a soft template in the formation of as prepared hollow microspheres. It is found that the pH values and the reaction temperature are two crucial factors in determining the phase, morphology and luminescence properties of the Y 2 O 3 : Eu hollow microspheres. Morphology evolution can be achieved by changing the pH and the reaction temperature. The properties of the Eu 3+ -doped Y 2 O 3 : Eu nanocrystals were characterized by XRD, FE-SEM, HR-TEM and UV–vis spectroscopy.

  1. Dosimetry and prescription in liver radioembolization with 90Y microspheres: 3D calculation of tumor-to-liver ratio from global 99mTc-MAA SPECT information

    Science.gov (United States)

    Mañeru, Fernando; Abós, Dolores; Bragado, Laura; Fuentemilla, Naiara; Caudepón, Fernando; Pellejero, Santiago; Miquelez, Santiago; Rubio, Anastasio; Goñi, Elena; Hernández-Vitoria, Araceli

    2017-12-01

    Dosimetry in liver radioembolization with 90Y microspheres is a fundamental tool, both for the optimization of each treatment and for improving knowledge of the treatment effects in the tissues. Different options are available for estimating the administered activity and the tumor/organ dose, among them the so-called partition method. The key factor in the partition method is the tumor/normal tissue activity uptake ratio (T/N), which is obtained by a single-photon emission computed tomography (SPECT) scan during a pre-treatment simulation. The less clear the distinction between healthy and tumor parenchyma within the liver, the more difficult it becomes to estimate the T/N ratio; therefore the use of the method is limited. This study presents a methodology to calculate the T/N ratio using global information from the SPECT. The T/N ratio is estimated by establishing uptake thresholds consistent with previously performed volumetry. This dose calculation method was validated against 3D voxel dosimetry, and was also compared with the standard partition method based on freehand regions of interest (ROI) outlining on SPECT slices. Both comparisons were done on a sample of 20 actual cases of hepatocellular carcinoma treated with resin microspheres. The proposed method and the voxel dosimetry method yield similar results, while the ROI-based method tends to over-estimate the dose to normal tissues. In addition, the variability associated with the ROI-based method is more extreme than the other methods. The proposed method is simpler than either the ROI or voxel dosimetry approaches and avoids the subjectivity associated with the manual selection of regions.

  2. Development of 90Sr/90Y Generator Systems Based on SLM Techniques for Radiolabelling of Therapeutic Biomolecules with 90Y. Chapter 14

    International Nuclear Information System (INIS)

    Thu, N.T.; Van Dong, D.; Van Cuong, B.; Van Khoa, C.; Cam Hoa, V.T.

    2015-01-01

    Yttrium-90 is one of the most useful radionuclides for radioimmunotherapeutic applications, especially for labelling peptides and antibodies. Studies were carried out to develop a 90 Sr/ 90 Y generator system based on the SLM technique. Two stages of 90 Sr/ 90 Y generator systems were developed at different activity levels of 5, 20, 50 and 100 mCi and operated with semiautomation in sequential mode. In the first stage of the system, PC88A based SLM was used, which transported 90 Y from a nitric acid medium containing 0.01–4M HNO 3 . In the second stage, the 90 Y from the first stage was transferred to the first compartment of the second stage using carbamoylmethyl phosphine oxide (CMPO) based SLM where 1M acetic acid was used as the receiving phase for 90 Y. Quality control was carried out for the products of 90 Y using EPC with paper chromatography and Tec control chromatography. Peptides and antibodies were labelled using the 90 Y product obtained from the generator developed in house. (author)

  3. A method for energy window optimization for quantitative tasks that includes the effects of model-mismatch on bias: application to Y-90 bremsstrahlung SPECT imaging

    International Nuclear Information System (INIS)

    Rong Xing; Du Yong; Frey, Eric C

    2012-01-01

    Quantitative Yttrium-90 ( 90 Y) bremsstrahlung single photon emission computed tomography (SPECT) imaging has shown great potential to provide reliable estimates of 90 Y activity distribution for targeted radionuclide therapy dosimetry applications. One factor that potentially affects the reliability of the activity estimates is the choice of the acquisition energy window. In contrast to imaging conventional gamma photon emitters where the acquisition energy windows are usually placed around photopeaks, there has been great variation in the choice of the acquisition energy window for 90 Y imaging due to the continuous and broad energy distribution of the bremsstrahlung photons. In quantitative imaging of conventional gamma photon emitters, previous methods for optimizing the acquisition energy window assumed unbiased estimators and used the variance in the estimates as a figure of merit (FOM). However, for situations, such as 90 Y imaging, where there are errors in the modeling of the image formation process used in the reconstruction there will be bias in the activity estimates. In 90 Y bremsstrahlung imaging this will be especially important due to the high levels of scatter, multiple scatter, and collimator septal penetration and scatter. Thus variance will not be a complete measure of reliability of the estimates and thus is not a complete FOM. To address this, we first aimed to develop a new method to optimize the energy window that accounts for both the bias due to model-mismatch and the variance of the activity estimates. We applied this method to optimize the acquisition energy window for quantitative 90 Y bremsstrahlung SPECT imaging in microsphere brachytherapy. Since absorbed dose is defined as the absorbed energy from the radiation per unit mass of tissues in this new method we proposed a mass-weighted root mean squared error of the volume of interest (VOI) activity estimates as the FOM. To calculate this FOM, two analytical expressions were derived for

  4. A method for energy window optimization for quantitative tasks that includes the effects of model-mismatch on bias: application to Y-90 bremsstrahlung SPECT imaging.

    Science.gov (United States)

    Rong, Xing; Du, Yong; Frey, Eric C

    2012-06-21

    Quantitative Yttrium-90 ((90)Y) bremsstrahlung single photon emission computed tomography (SPECT) imaging has shown great potential to provide reliable estimates of (90)Y activity distribution for targeted radionuclide therapy dosimetry applications. One factor that potentially affects the reliability of the activity estimates is the choice of the acquisition energy window. In contrast to imaging conventional gamma photon emitters where the acquisition energy windows are usually placed around photopeaks, there has been great variation in the choice of the acquisition energy window for (90)Y imaging due to the continuous and broad energy distribution of the bremsstrahlung photons. In quantitative imaging of conventional gamma photon emitters, previous methods for optimizing the acquisition energy window assumed unbiased estimators and used the variance in the estimates as a figure of merit (FOM). However, for situations, such as (90)Y imaging, where there are errors in the modeling of the image formation process used in the reconstruction there will be bias in the activity estimates. In (90)Y bremsstrahlung imaging this will be especially important due to the high levels of scatter, multiple scatter, and collimator septal penetration and scatter. Thus variance will not be a complete measure of reliability of the estimates and thus is not a complete FOM. To address this, we first aimed to develop a new method to optimize the energy window that accounts for both the bias due to model-mismatch and the variance of the activity estimates. We applied this method to optimize the acquisition energy window for quantitative (90)Y bremsstrahlung SPECT imaging in microsphere brachytherapy. Since absorbed dose is defined as the absorbed energy from the radiation per unit mass of tissues in this new method we proposed a mass-weighted root mean squared error of the volume of interest (VOI) activity estimates as the FOM. To calculate this FOM, two analytical expressions were

  5. A Woman with Black Beads in Her Stomach: Severe Gastric Ulceration Caused by Yttrium-90 Radioembolization

    Directory of Open Access Journals (Sweden)

    Indu S. Voruganti

    2018-01-01

    Full Text Available Radioembolization (RE is a selective internal radiation therapy (SIRT delivering targeted, high-dose, intra-arterial radiation directly to the vascular supply of liver tumors. Complications can occur due to aberrant deposition or migration of radiation microspheres into nontarget locations, including normal hepatic parenchyma, lungs, pancreas, and upper gastrointestinal (UGI tract. We report a case of gastric ulcers due to yttrium-90 (90Y seed migration to the stomach to alert clinicians to this rare cause of gastric injury. A 57-year-old woman with stage IV breast cancer with liver and lung metastases presented to the hospital with 2 months of worsening nausea and vomiting. Two months prior, she had received SIRT with 90Y microspheres without complications. Upper GI endoscopy showed diffuse gastritis and extensive antral ulceration. Biopsies revealed black, spherical foreign bodies, consistent with 90Y microspheres, documenting radiation injury. Radiation-induced UGI ulceration is caused by direct radiation injury from beta-radiation. Delay in diagnosis may be due to the nonspecificity of symptoms and temporal delay of symptom onset from SIRT, which was 2 months in our patient. Also, complaints may be attributed erroneously to adjuvant chemotherapy or widespread metastatic disease. Clinicians must consider radiation-associated toxicity in any SIRT-treated patient developing abdominal symptoms.

  6. Validation of an extraction paper chromatography (EPC) technique for estimation of trace levels of 90Sr in 90Y solutions obtained from 90Sr/90Y generator systems

    International Nuclear Information System (INIS)

    Usha Pandey; Yogendra Kumar; Ashutosh Dash

    2014-01-01

    While the extraction paper chromatography (EPC) technique constitutes a novel paradigm for the determination of few Becquerels of 90 Sr in MBq quantities of 90 Y obtained from 90 Sr/ 90 Y generator, validation of the technique is essential to ensure its usefulness as a real time analytical tool. With a view to explore the relevance and applicability of EPC technique as a real time quality control (QC) technique for the routine estimation of 90 Sr content in generator produced 90 Y, a systematic validation study was carried out diligently not only to establish its worthiness but also to broaden its horizon. The ability of the EPC technique to separate trace amounts of Sr 2+ in the presence of large amounts of Y 3+ was verified. The specificity of the technique for Y 3+ was demonstrated with 90 Y obtained by neutron irradiation. The method was validated under real experimental conditions and compared with a QC method described in US Pharmacopeia for detection of 90 Sr levels in 90 Y radiopharmaceuticals. (author)

  7. Treatment of primary liver tumors with Yttrium-90 microspheres (TheraSphere) in high risk patients: analysis of survival and toxicities.

    Science.gov (United States)

    Reardon, Kelli A; McIntosh, Alyson F; Shilling, A Tanner; Hagspiel, Klaus D; Al-Osaimi, Abdullah; Berg, Carl; Caldwell, Stephen H; Northup, Patrick G; Angle, Fritz; Mulder, Robert; Rich, Tyvin A

    2009-02-01

    This retrospective study was undertaken to obtain information regarding the survival and toxicities after Yttrium-90 microspheres treatment in patients with primary liver malignancies. Baseline, treatment, and follow-up data were collected and analyzed for 21 patients treated with Yttrium-90 microspheres. Survival analysis was then performed. The results of this study showed that median survival for all the patients was 120 days. Twenty of 21 patients were categorized as high-risk with a median survival of 114 days. It was also found that one high-risk patient has survived 858 days with no recurrence of disease. Acute grade 3-5 toxicities were recorded for nine patients and consisted of elevations in AST and bilirubin, thrombocytopenia, abdominal pain, ascites, nausea, fatigue, and death. This study concluded that Yttrium-90 is a low-toxicity, outpatient alternative for individuals with liver cancer and without many options. The maximal value, however, may lie in the treatment of low-risk patients.

  8. Extractive {sup 90}Y generator

    Energy Technology Data Exchange (ETDEWEB)

    Kodina, G.E. [State Scientific Center, Moscow (Russian Federation). Institute of Giophysics; Korpusov, G.V.; Filyanin, A.T. [Russian Academy of Sciences, Moscow (Russian Federation). Institute of Physical Chemistry

    1997-10-01

    The generator for {sup 90}Y production is made up of two units - an extractive unit and a unit for deep purification. Contrary to the well-known methods of {sup 90}Y separation two mineral acids are used in the developed technology. The solutions of nitric acid are used for preliminary separation of {sup 90}Y and the solutions of hydrochloric acid are used for the deep purification of {sup 90}Y from {sup 90}Sr and stripping. The optimum conditions for carrying out this technology were found. The following results are reported: the carry-over of the stationary phase is excluded in this generator; the separation time is 30-60 minutes; the yield of the final product is not less than 95%; impurity of {sup 90}Sr is not more than 10{sup -9-}-{sup -10}%; the content of the chemical (nonactive) impurities is not more than the allowed one for radiopharmaceuticals 4 refs., 4 tabs., 5 figs.

  9. Early post-treatment FDG PET predicts survival after {sup 90}Y microsphere radioembolization in liver-dominant metastatic colorectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Sabet, Amir; Aouf, Anas; Sabet, Amin; Ghamari, Shahab; Biersack, Hans-Juergen [University Hospital, Department of Nuclear Medicine, Bonn (Germany); Meyer, Carsten; Pieper, Claus C. [University Hospital, Department of Radiology, Bonn (Germany); Mayer, Karin [University Hospital, Department of Medicine and Oncology, Bonn (Germany); Ezziddin, Samer [University Hospital, Department of Nuclear Medicine, Bonn (Germany); Saarland University, Department of Nuclear Medicine, Homburg (Germany)

    2014-10-29

    The aim of this study was to evaluate the predictive value of early metabolic response 4 weeks post-treatment using {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT in patients with unresectable hepatic metastases of colorectal cancer (CRC) undergoing radioembolization (RE) with {sup 90}Y-labelled microspheres. A total of 51 consecutive patients with liver-dominant metastases of CRC were treated with RE and underwent {sup 18}F-FDG PET/CT at baseline and 4 weeks after RE. In each patient, three hepatic metastases with the highest maximum standardized uptake value (SUV{sub max}) were selected as target lesions. Metabolic response was defined as >50 % reduction of tumour to liver ratios. Survival analyses using Kaplan-Meier and multivariate analyses were performed to identify prognostic factors for overall survival (OS). Investigated baseline characteristics included age (>60 years), performance status (Eastern Cooperative Oncology Group >1), bilirubin (>1.0 mg/dl), hepatic tumour burden (>25 %) and presence of extrahepatic disease. The median OS after RE was 7 months [95 % confidence interval (CI) 5-8]; early metabolic responders (n = 33) survived longer than non-responders (p < 0.001) with a median OS of 10 months (95 % CI 3-16) versus 4 months (95 % CI 2-6). Hepatic tumour burden also had significant impact on treatment outcome (p < 0.001) with a median OS of 5 months (95 % CI, 3-7) for patients with >25 % metastatic liver replacement vs 14 months (95 % CI 6-22) for the less advanced patients. Both factors (early metabolic response and low hepatic tumour burden) remained as independent predictors of improved survival on multivariate analysis. These are the first findings to show that molecular response assessment in CRC using {sup 18}F-FDG PET/CT appears feasible as early as 4 weeks post-RE, allowing risk stratification and potentially facilitating early response-adapted treatment strategies. (orig.)

  10. Experimental autoabsorption curve 90Sr in SrCO3. Efficiency calculation to detection of 90Sr, 90Y and 90Sr + 90Y in a beta gas proportional counter

    International Nuclear Information System (INIS)

    Gasco, C.; Alvarez, A.

    1987-01-01

    Strontium-90 has been determined by radiochemical separation techniques in environmental samples. These techniques, of course, cannot separate the two strontium radionuclides from each other of from stable strontium. Consequently the end product of the chemical separation contains all strontium isotopes in SrCO 3 . The beta particules emitted by 90 Sr are absorbed by the SrCO 3 precipitate. This is the main source of error in the activity measurement. It has been prepared sources of 90 Sr in SrCO 3 in order to determinate the counting efficiency and autoabsorption curve. Also detection efficiencies have been calibrated using known activities of 90 Y and equilibrium mixture of 90 Sr+ 90 Y in the same geometry than our samples. The activity of 90 Sr by ingrowth of 90 Y has been calculated by our computer program. (author). 2 figs., 3 refs

  11. 90Sr-90Y radionuclide generator based on ionex chromatography. Part 1 - project

    International Nuclear Information System (INIS)

    Miler, V.; Budsky, F.; Malek, Z.

    2003-09-01

    This part contains a proposal for the generator column design, materials to be used (chemicals, ionexes) and technological procedures. The proposal was inspired by the 90 Sr- 90 Y generator operated by Zfk Rossendorf. The aim was to develop and launch a generator for the preparation of carrier-free 90 Y in the form of [ 90 Y] chloride solution in dilute hydrochloric acid. The separation of Y from Sr is based on ionex chromatography by sorbing the two radionuclides on a catex. While Sr remains sorbed, 90 Y is eluted with lithium citrate. During this process, 90 Y is bonded in a citrate complex which, having a negative charge, is subsequently trapped by an anex. A guard column is inserted before the anex column to trap any traces of 90 Sr. 90 Y is eluted from the anex in the yttrium chloride form by using dilute hydrochloric acid. The product from the generator can be used for the preparation of [ 90 Y] - Fe colloid injection or [ 90 Y] - yttrium citrate injection for intra-articular application or for the development of monoclonal antibodies and peptides

  12. Peripheral Blood Lymphocyte Depletion After Hepatic Arterial {sup 90}Yttrium Microsphere Therapy for Hepatocellular Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Carr, Brian I., E-mail: brianicarr@hotmail.com [Department of Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA and Department of Nutrition and Exptl Biology, Saverio De Bellis Medical Research Institute, Castellana Grotte, Bari (Italy); Metes, Diana M. [Department of Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA and Department of Nutrition and Exptl Biology, Saverio De Bellis Medical Research Institute, Castellana Grotte, Bari (Italy)

    2012-03-01

    Purpose: The short- and long-term effects of {sup 90}Yttrium microspheres therapy for hepatocellular carcinoma (HCC) on peripheral blood lymphocytes are unknown and were therefore examined. Methods and Materials: Ninety-two HCC patients were enrolled in a {sup 90}Yttrium therapy study and routine blood counts were examined as part of standard clinical monitoring. Results: We found an early, profound, and prolonged lymphopenia. In a subsequent cohort of 25 additional HCC patients, prospective flow cytometric immune-monitoring analysis was performed to identify specific changes on distinct lymphocyte subsets (i.e., CD3, CD4, CD8 T, and CD19 B lymphocytes) and NK cells absolute numbers, in addition to the granulocytes and platelets subsets. We found that the pretreatment lymphocyte subset absolute numbers (with the exception of NK cells) had a tendency to be lower compared with healthy control values, but no significant differences were detected between groups. Posttherapy follow-up revealed that overall, all lymphocyte subsets, except for NK cells, were significantly (>50% from pretherapy values), promptly (as early as 24 h) and persistently (up to 30 months) depleted post-{sup 90}Yttrium microspheres therapy. In contrast, granulocytes increased rapidly (24 h) to compensate for lymphocyte depletion, and remained increased at 1-year after therapy. We further stratified patients into two groups, according to survival at 1 year. We found that lack of recovery of CD19, CD3, CD8, and especially CD4 T cells was linked to poor patient survival. No fungal or bacterial infections were noted during the 30-month follow-up period. Conclusions: The results show that lymphocytes (and not granulocytes, platelets, or NK cells) are sensitive to hepatic arterial {sup 90}Yttrium without associated clinical toxicity, and lack of lymphocyte recovery (possibly leading to dysregulation of adaptive cellular immunity) posttherapy indicates poor survival.

  13. Development of methodology for the preparation of 90Sr-90Y generators

    International Nuclear Information System (INIS)

    Barrio, Graciela; Osso, Joao A.

    2008-01-01

    Among the more attractive radionuclides for therapeutic applications is yttrium-90. Its relatively short half-life (64.0h), maximum beta energy (2.28 MeV) make it well suited for a variety of applications, ranging from the radiolabeling of antibodies for tumor therapy to the production of radiolabeled particles for the treatment of liver malignancies. Yttrium-90 results from the decay of strontium-90 (28y) and decays to a stable daughter ( 90 Zr) and has no γ-ray, what makes this nuclide very attractive for therapeutic applications. 90 Y is produced through a generator system, from the decay of 90 Sr. Before it can safely employed in clinical applications, the 90 Y must be made essentially free of 90 Sr, an isotope known to cause bone marrow suppression. The objective of this work is to develop 90 Sr- 90 Y generator using a cation exchange method resin. This method was the most effects for the separation of 90 Y and 90 Sr. 90 Sr is strongly adsorbed in the resin and 90 Y is eluted in 0.003M EDTA. The generator efficiency and radionuclide control results were also evaluated using 85 Sr (γ-ray emitter). The generator was developed, using AG 50WX8 exchange resin converted to the Na+ form and then conditioned with 0.003M EDTA solution (pH=4.8). The quality control showed that 90 Y had no 8 '5Sr impurities, inside the detection limits of the detector. The results presented here are very promising, showing that the methodology is able to separate the two nuclides, with low quantities of 90 Sr impurity and satisfactory elution yields. (author)

  14. Yttrium-90 Resin Microsphere Radioembolization Using an Antireflux Catheter: An Alternative to Traditional Coil Embolization for Nontarget Protection

    International Nuclear Information System (INIS)

    Morshedi, Maud M.; Bauman, Michael; Rose, Steven C.; Kikolski, Steven G.

    2015-01-01

    PurposeSerious complications can result from nontarget embolization during yttrium-90 (Y-90) transarterial radioembolization. Hepatoenteric artery coil embolization has been traditionally performed to prevent nontarget radioembolization. The U.S. Food and Drug Administration–approved Surefire Infusion System (SIS) catheter, designed to prevent reflux, is an alternative to coils. The hypothesis that quantifiable SIS procedural parameters are comparable to coil embolization was tested.MethodsFourteen patients aged 36–79 years with colorectal, neuroendocrine, hepatocellular, and other predominantly bilobar hepatic tumors who underwent resin microsphere Y-90 radioembolization using only the SIS catheter (n = 7) versus only detachable coils (n = 7) for nontarget protection were reviewed retrospectively. Procedure time, fluoroscopy time, contrast dose, radiation dose, and cost were evaluated.ResultsMultivariate analysis identified significant cohort differences in the procedural parameters evaluated (F(10, 3) = 10.39, p = 0.04). Between-group comparisons of the pretreatment planning procedure in the SIS catheter group compared to the coil embolization group demonstrated a significant reduction in procedure time (102.6 vs. 192.1 min, respectively, p = 0.0004), fluoroscopy time (14.3 vs. 49.7 min, respectively, p = 0.0016), and contrast material dose (mean dose of 174.3 vs. 265.0 mL, respectively, p = 0.0098). Procedural parameters were not significantly different between the two groups during subsequent dose delivery procedures. Overall cost of combined first-time radioembolization procedures was significantly less in the SIS group ($4252) compared to retrievable coil embolization ($11,123; p = 0.001).ConclusionThe SIS catheter results in a reduction in procedure time, fluoroscopy time, and contrast material dose and may be an attractive cost-effective alternative to detachable coil embolization for prevention of nontarget radioembolization

  15. Yttrium-90 Resin Microsphere Radioembolization Using an Antireflux Catheter: An Alternative to Traditional Coil Embolization for Nontarget Protection

    Energy Technology Data Exchange (ETDEWEB)

    Morshedi, Maud M., E-mail: maud.morshedi@my.rfums.org; Bauman, Michael, E-mail: mbauman@ucsd.edu; Rose, Steven C., E-mail: scrose@ucsd.edu; Kikolski, Steven G., E-mail: skikolski@gmail.com [University of California San Diego Health Sciences, Radiology Department, University of California San Diego Medical Center (United States)

    2015-04-15

    PurposeSerious complications can result from nontarget embolization during yttrium-90 (Y-90) transarterial radioembolization. Hepatoenteric artery coil embolization has been traditionally performed to prevent nontarget radioembolization. The U.S. Food and Drug Administration–approved Surefire Infusion System (SIS) catheter, designed to prevent reflux, is an alternative to coils. The hypothesis that quantifiable SIS procedural parameters are comparable to coil embolization was tested.MethodsFourteen patients aged 36–79 years with colorectal, neuroendocrine, hepatocellular, and other predominantly bilobar hepatic tumors who underwent resin microsphere Y-90 radioembolization using only the SIS catheter (n = 7) versus only detachable coils (n = 7) for nontarget protection were reviewed retrospectively. Procedure time, fluoroscopy time, contrast dose, radiation dose, and cost were evaluated.ResultsMultivariate analysis identified significant cohort differences in the procedural parameters evaluated (F(10, 3) = 10.39, p = 0.04). Between-group comparisons of the pretreatment planning procedure in the SIS catheter group compared to the coil embolization group demonstrated a significant reduction in procedure time (102.6 vs. 192.1 min, respectively, p = 0.0004), fluoroscopy time (14.3 vs. 49.7 min, respectively, p = 0.0016), and contrast material dose (mean dose of 174.3 vs. 265.0 mL, respectively, p = 0.0098). Procedural parameters were not significantly different between the two groups during subsequent dose delivery procedures. Overall cost of combined first-time radioembolization procedures was significantly less in the SIS group ($4252) compared to retrievable coil embolization ($11,123; p = 0.001).ConclusionThe SIS catheter results in a reduction in procedure time, fluoroscopy time, and contrast material dose and may be an attractive cost-effective alternative to detachable coil embolization for prevention of nontarget radioembolization.

  16. SU-C-204-01: A Dosimetric Investigation Into the Effects of Yttrium-90 Radioembolization On the GI Tract: In-Vivo and Histological Analysis in An Animal Model

    Energy Technology Data Exchange (ETDEWEB)

    Pasciak, A [University of Tennessee Medical Center, Knoxville, TN (United States); The University of Tennessee Graduate School of Medicine, Knoxville, TN (United States); Nodit, L; Bourgeois, A; Bradley, Y [The University of Tennessee Graduate School of Medicine, Knoxville, TN (United States); Paxton, B [Duke university medical center, Durham, NC (United States); Arepally, A [Vanderbilt University Medical Center, Nashville, TN (United States)

    2016-06-15

    Purpose: In Yttrium-90 (90Y) radioembolization, non-target embolization (NTE) to the stomach or small bowel can result in ulceration, a rare but difficult to manage clinical complication. However, dosimetric thresholds for toxicity to these tissues from radioembolization have never been evaluated in a controlled setting. We performed an analysis of the effect of 90Y radioembolization in a porcine model at different absorbed-dose endpoints. Methods: Under approval of the University of Tennessee IACUC, 6 female pigs were included in this study. Animals underwent transfemoral angiography and infusion of calibrated dosages of 90Y resin microspheres into arteries supplying part of the gastric wall. A 99mTc-MAA simulation study was performed first to determine perfused tissue volume for treatment planning along with contrast-enhanced CT. The pigs were monitored for side effects for 9 weeks, after which time they were euthanized and their upper gastrointestinal tracts were harvested for analysis. Results: 90Y radioembolization was infused resulting in average absorbed doses of between 35.5 and 91.9 Gy to the gastric wall. No animal exhibited any signs of pain or gastrointestinal distress through the duration of the study. Excised tissue showed 1–2 small (<3.0 cm2) healed or healing superficial gastric lesions in 5 out of 6 animals. Histologic analysis demonstrated that lesion location was superficial to areas of abnormally high microsphere deposition. An analysis of microsphere deposition patterns within the gastric wall indicated a high preference for submucosal deposition. Dosimetric evaluation at the luminal mucosa performed based on microsphere deposition patterns confirmed that 90Y dosimetry techniques conventionally used in hepatic dosimetry provide a reasonable estimate of absorbed dose. Conclusion: The upper gastrointestinal tract may be less sensitive to 90Y radioembolization than previously thought. Lack of charged-particle equilibrium at the luminal mucosa

  17. Phase transformation, morphology evolution and luminescence property variation in Y{sub 2}O{sub 3}: Eu hollow microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Qin; Guo, Jing; Jia, Wenjing; Liu, Baocang [College of Chemistry and Chemical Engineering, Inner Mongolia University, Hohhot (China); Zhang, Jun, E-mail: cejzhang@sina.com [College of Chemistry and Chemical Engineering, Inner Mongolia University, Hohhot (China)

    2012-11-25

    Highlights: Black-Right-Pointing-Pointer We report a general and facile method for the synthesis of Y{sub 2}O{sub 3}: Eu hollow microspheres. Black-Right-Pointing-Pointer This method may be of great significance in the synthesis of many other hollow spherical materials. Black-Right-Pointing-Pointer Phase, morphology and luminescence property were found to be strongly dependent on temperature and pH. Black-Right-Pointing-Pointer The evolution process under various temperatures and pH values were discussed. Black-Right-Pointing-Pointer The sample shows a strong red emission under short UV irradiation, and the lifetime is determined to be 7.0 ms. - Abstract: Y{sub 2}O{sub 3}: Eu hollow microspheres with average size of 500-600 nm have been successfully synthesized via a solvothermal method in the presence of sodium citrate as surfactant followed by a subsequent heat treatment process. High polymer F127(EO{sub 106}PO{sub 70}EO{sub 106}) served as a soft template in the formation of as prepared hollow microspheres. It is found that the pH values and the reaction temperature are two crucial factors in determining the phase, morphology and luminescence properties of the Y{sub 2}O{sub 3}: Eu hollow microspheres. Morphology evolution can be achieved by changing the pH and the reaction temperature. The properties of the Eu{sup 3+}-doped Y{sub 2}O{sub 3}: Eu nanocrystals were characterized by XRD, FE-SEM, HR-TEM and UV-vis spectroscopy.

  18. SU-E-T-02: 90Y Microspheres Dosimetry Calculation with Voxel-S-Value Method: A Simple Use in the Clinic

    International Nuclear Information System (INIS)

    Maneru, F; Gracia, M; Gallardo, N; Olasolo, J; Fuentemilla, N; Bragado, L; Martin-Albina, M; Lozares, S; Pellejero, S; Miquelez, S; Rubio, A; Otal, A

    2015-01-01

    Purpose: To present a simple and feasible method of voxel-S-value (VSV) dosimetry calculation for daily clinical use in radioembolization (RE) with 90 Y microspheres. Dose distributions are obtained and visualized over CT images. Methods: Spatial dose distributions and dose in liver and tumor are calculated for RE patients treated with Sirtex Medical miscrospheres at our center. Data obtained from the previous simulation of treatment were the basis for calculations: Tc-99m maggregated albumin SPECT-CT study in a gammacamera (Infinia, General Electric Healthcare.). Attenuation correction and ordered-subsets expectation maximization (OSEM) algorithm were applied.For VSV calculations, both SPECT and CT were exported from the gammacamera workstation and registered with the radiotherapy treatment planning system (Eclipse, Varian Medical systems). Convolution of activity matrix and local dose deposition kernel (S values) was implemented with an in-house developed software based on Python code. The kernel was downloaded from www.medphys.it. Final dose distribution was evaluated with the free software Dicompyler. Results: Liver mean dose is consistent with Partition method calculations (accepted as a good standard). Tumor dose has not been evaluated due to the high dependence on its contouring. Small lesion size, hot spots in health tissue and blurred limits can affect a lot the dose distribution in tumors. Extra work includes: export and import of images and other dicom files, create and calculate a dummy plan of external radiotherapy, convolution calculation and evaluation of the dose distribution with dicompyler. Total time spent is less than 2 hours. Conclusion: VSV calculations do not require any extra appointment or any uncomfortable process for patient. The total process is short enough to carry it out the same day of simulation and to contribute to prescription decisions prior to treatment. Three-dimensional dose knowledge provides much more information than other

  19. SU-E-T-02: 90Y Microspheres Dosimetry Calculation with Voxel-S-Value Method: A Simple Use in the Clinic

    Energy Technology Data Exchange (ETDEWEB)

    Maneru, F; Gracia, M; Gallardo, N; Olasolo, J; Fuentemilla, N; Bragado, L; Martin-Albina, M; Lozares, S; Pellejero, S; Miquelez, S; Rubio, A [Complejo Hospitalario de Navarra, Pamplona, Navarra (Spain); Otal, A [Hospital Clinica Benidorm, Benidorm, Alicante (Spain)

    2015-06-15

    Purpose: To present a simple and feasible method of voxel-S-value (VSV) dosimetry calculation for daily clinical use in radioembolization (RE) with {sup 90}Y microspheres. Dose distributions are obtained and visualized over CT images. Methods: Spatial dose distributions and dose in liver and tumor are calculated for RE patients treated with Sirtex Medical miscrospheres at our center. Data obtained from the previous simulation of treatment were the basis for calculations: Tc-99m maggregated albumin SPECT-CT study in a gammacamera (Infinia, General Electric Healthcare.). Attenuation correction and ordered-subsets expectation maximization (OSEM) algorithm were applied.For VSV calculations, both SPECT and CT were exported from the gammacamera workstation and registered with the radiotherapy treatment planning system (Eclipse, Varian Medical systems). Convolution of activity matrix and local dose deposition kernel (S values) was implemented with an in-house developed software based on Python code. The kernel was downloaded from www.medphys.it. Final dose distribution was evaluated with the free software Dicompyler. Results: Liver mean dose is consistent with Partition method calculations (accepted as a good standard). Tumor dose has not been evaluated due to the high dependence on its contouring. Small lesion size, hot spots in health tissue and blurred limits can affect a lot the dose distribution in tumors. Extra work includes: export and import of images and other dicom files, create and calculate a dummy plan of external radiotherapy, convolution calculation and evaluation of the dose distribution with dicompyler. Total time spent is less than 2 hours. Conclusion: VSV calculations do not require any extra appointment or any uncomfortable process for patient. The total process is short enough to carry it out the same day of simulation and to contribute to prescription decisions prior to treatment. Three-dimensional dose knowledge provides much more information than

  20. The prognostic value of functional and anatomical parameters for the selection of patients receiving yttrium-90 microspheres for the treatment of liver cancer

    Science.gov (United States)

    Mesoloras, Geraldine

    Yttrium-90 (90Y) microsphere therapy is being utilized as a treatment option for patients with primary and metastatic liver cancer due to its ability to target tumors within the liver. The success of this treatment is dependent on many factors, including the extent and type of disease and the nature of prior treatments received. Metabolic activity, as determined by PET imaging, may correlate with the number of viable cancer cells and reflect changes in viable cancer cell volume. However, contouring of PET images by hand is labor intensive and introduces an element of irreproducibility into the determination of functional target/tumor volume (FTV). A computer-assisted method to aid in the automatic contouring of FTV has the potential to substantially improve treatment individualization and outcome assessment. Commercial software to determine FTV in FDG-avid primary and metastatic liver tumors has been evaluated and optimized. Volumes determined using the automated technique were compared to those from manually drawn contours identified using the same cutoff in the standard uptake value (SUV). The reproducibility of FTV is improved through the introduction of an optimal threshold value determined from phantom experiments. Application of the optimal threshold value from the phantom experiments to patient scans was in good agreement with hand-drawn determinations of the FTV. It is concluded that computer-assisted contouring of the FTV for primary and metastatic liver tumors improves reproducibility and increases accuracy, especially when combined with the selection of an optimal SUV threshold determined from phantom experiments. A method to link the pre-treatment assessment of functional (PET based) and anatomical (CT based) parameters to post-treatment survival and time to progression was evaluated in 22 patients with colorectal cancer liver metastases treated using 90Y microspheres and chemotherapy. The values for pre-treatment parameters that were the best

  1. 90Y of high purity for medical applications

    International Nuclear Information System (INIS)

    Castillo, A.X.; Alvarez, E.O.; Olive, K.I.

    2001-01-01

    Several 90 Sr/ 90 Y-generator systems have been developed and used to produce 90 Y. The most important parameter of the 90 Y to be assayed is 90 Sr content. In addition, when labelling monoclonal antibodies for therapy trace metal quantities accompanying 90 Y (Fe 3+ , Zn 2+ , Cu 2+ , ZrO 2+ , etc.) are to be kept as low as possible in order to obtain high labelling efficiencies. Generally generators' lifetime is limited due to the 90 Sr breakthrough which increases in eluates as a result of the radiolytic degradation of the resin used as support. In the study a described procedure for 90 Y purification from metal contamination is modified in order to lower the amount of 90 Sr present in eluates from generators. As a result a very low 90 Sr content is always assured ( 90 Sr/ 90 Y -6 ). (author)

  2. Safety and efficacy of Y-90 microsphere treatment in patients with primary and metastatic liver cancer: The tumor selectivity of the treatment as a function of tumor to liver flow ratio

    Directory of Open Access Journals (Sweden)

    Dezarn William A

    2007-03-01

    Full Text Available Abstract Background Treatment records and follow-up data on 40 patients with primary and metastatic liver malignancies who underwent a single whole-liver treatment with Y-90 resin microspheres (SIR-Spheres® Sirtex Medical, Lake Forest, IL were retrospectively reviewed. The objective of the study was to evaluate the anatomic and physiologic determinants of radiation dose distribution, and the dose response of tumor and liver toxicity in patients with liver malignancies who underwent hepatic arterial Y-90 resin microsphere treatment. Methods Liver and tumor volume calculations were performed on pre-treatment CT scans. Fractional tumor and liver flow characteristics and lung shunt fractions were determined using hepatic arterial Tc-99m MAA imaging. Absorbed dose calculations were performed using the MIRD equations. Liver toxicity was assessed clinically and by liver function tests. Tumor response to therapy was assessed by CT and/or tumor markers. Results Of the 40 patients, 5 had hepatocellular cancer (HCC, and 35 had metastatic liver tumors (15 colorectal cancer, 10 neuroendocrine tumors, 4 breast cancer, 2 lung cancer, 1 ovarian cancer, 1 endometrial cancer, and 2 unknown primary adenocarcinoma. All patients were treated in a salvage setting with a 3 to 80 week follow-up (mean: 19 weeks. Tumor volumes ranged from 15.0 to 984.2 cc (mean: 294.9 cc and tumor to normal liver uptake ratios ranged from 2.8 to 15.4 (mean: 5.4. Average administered activity was 1.2 GBq (0.4 to 2.4 GBq. Liver absorbed doses ranged from 0.7 to 99.5 Gy (mean: 17.2 Gy. Tumor absorbed doses ranged from 40.1 to 494.8 Gy (mean: 121.5 Gy. None of the patients had clinical venoocclusive disease or therapy-induced liver failure. Seven patients (17.5 % had transient and 7 patients (17.5 % had persistent LFT abnormalities. There were 27 (67.5% responders (complete response, partial response, and stable disease. Tumor response correlated with higher tumor flow ratio as measured by

  3. Yttrium-90 radioembolization using TheraSphere in the management of primary and secondary liver tumors.

    Science.gov (United States)

    Riaz, A; Lewandowski, R J; Kulik, L; Salem, R

    2009-06-01

    Locoregional therapies, such as transarterial chemoembolization, radioembolization and thermal ablation (e.g., radiofrequency ablation) are establishing their roles in the management of liver malignancies. With yYttrium-90 radioembolization therapy (90Y) radionuclide labeled microspheres are injected into the tumor feeding artery. This allows the delivery of a high radioactive dose to the tumor with minimal toxicity to normal tissues. 90Y has demonstrated to be safe and effective in the management of liver tumors. Authors present a review of the literature available for the use of TheraSphere for radioembolization in the management of liver tumors.

  4. Preparation and characterization of composite microspheres for brachytherapy and hyperthermia treatment of cancer

    International Nuclear Information System (INIS)

    Zhao Di; Huang Wenhai; Rahaman, Mohamed N.; Day, Delbert E.; Wang Deping; Gu Yifei

    2012-01-01

    Composite microspheres were prepared by coating yttrium–aluminum–silicate (YAS) glass microspheres (20–30 μm) with a layer of Fe 3 O 4 nanoparticles and evaluated for potential use in brachytherapy and hyperthermia treatment of cancer. After neutron activation to form the β-emitting 90 Y radionuclide, the composite microspheres can be injected into a patient to destroy cancerous tumors; at the same time, the composite microspheres can generate heat upon application of a magnetic field to also destroy the tumors. The results showed that the composite microspheres were chemically durable when immersed in a simulated body fluid (SBF), with ∼ 0.25% weight loss and ∼ 3.2% yttrium dissolved into the SBF after 30 days at 37 °C. The composite microspheres also showed ferromagnetic properties as a result of the Fe 3 O 4 coating; when immersed in water at 20 °C (20 mg in 1 mL of water), the application of an alternating magnetic field produced a temperature increase from 20 °C to 38−46 °C depending on the thickness of the Fe 3 O 4 coating. The results indicate that these composite microspheres have promising potential in combined brachytherapy and hyperthermia treatment of cancerous tumors. - Highlights: ► Composite microspheres for brachytherapy and hyperthermia treatment of cancer. ► Fe 3 O 4 nanoparticles coated on the yttrium–aluminum–silicate glass microspheres. ► Microspheres are chemically stable in SBF. ► Microspheres can generate heat for hyperthermia under an alternating magnetic field. ► Microspheres can emit β-rays for brachytherapy after neutron activation.

  5. Treatment of diffuse large B-cell lymphoma of the liver with yttrium-90 microsphere embolization.

    Science.gov (United States)

    Fenske, Timothy S; Benjamin, Heather; Kroft, Steven H; Hohenwalter, Eric J; Rilling, William S

    2008-11-01

    A 41-year-old male with a 4-year history of chronic hepatitis C presented with a 1-month history of abdominal pain, fatigue, weight loss, and night sweats. Laboratory examinations, chest, abdomen, and pelvic CT scans, PET-CT scans, ultrasound-guided needle biopsies of liver lesions, bone-marrow biopsy, flow cytometry, and immunohistochemical staining for B-cell markers including CD20. Chemoresistant diffuse large B-cell lymphoma, with gradual loss of CD20 antigen expression. Embolization of hepatic tumors using yttrium-90 microspheres (Therasphere, Theragenics Corporation, Buford, GA).

  6. Review: microspheres for radioembolization therapy

    International Nuclear Information System (INIS)

    Zhao Mingqiang; Xu Shuhe

    2007-12-01

    Radioembolization of liver cancer has been proven to be an effective therapy in nuclear medicine. The yttrium-90 glass microspheres has been used to treat both primary and metastatic liver tumors in clinic which shown encouraging results. The preparation, stability, degradation and application for medical purpose of radioactive microspheres are reviewed. At first, the theory of radioem- bolization treating cancer is discussed; and then three major radiolabled micro- sphere materials are expounded: viz. glass, resin-based and polymer-based; Future improvements in the preparation and use of radioactive microspheres are prospected at last. (authors)

  7. Review: microspheres for radioembolization therapy

    Energy Technology Data Exchange (ETDEWEB)

    Mingqiang, Zhao; Shuhe, Xu [China Inst. of Atomic Energy, Beijing (China)

    2007-12-15

    Radioembolization of liver cancer has been proven to be an effective therapy in nuclear medicine. The yttrium-90 glass microspheres has been used to treat both primary and metastatic liver tumors in clinic which shown encouraging results. The preparation, stability, degradation and application for medical purpose of radioactive microspheres are reviewed. At first, the theory of radioem- bolization treating cancer is discussed; and then three major radiolabled micro- sphere materials are expounded: viz. glass, resin-based and polymer-based; Future improvements in the preparation and use of radioactive microspheres are prospected at last. (authors)

  8. Synthesis of plastic scintillation microspheres: Evaluation of scintillators

    International Nuclear Information System (INIS)

    Santiago, L.M.; Bagán, H.; Tarancón, A.; Garcia, J.F.

    2013-01-01

    The use of plastic scintillation microspheres (PSm) appear to be an alternative to liquid scintillation for the quantification of alpha and beta emitters because it does not generate mixed wastes after the measurement (organic and radioactive). In addition to routine radionuclide determinations, PSm can be used for further applications, e.g. for usage in a continuous monitoring equipment, for measurements of samples with a high salt concentration and for an extractive scintillation support which permits the separation, pre-concentration and measurement of the radionuclides without additional steps of elution and sample preparation. However, only a few manufacturers provide PSm, and the low number of regular suppliers reduces its availability and restricts the compositions and sizes available. In this article, a synthesis method based on the extraction/evaporation methodology has been developed and successfully used for the synthesis of plastic scintillation microspheres. Seven different compositions of plastic scintillation microspheres have been synthesised; PSm1 with polystyrene, PSm2 with 2,5-Diphenyloxazol(PPO), PSm3 with p-terphenyl (pT), PSm4 with PPO and 1,4-bis(5-phenyloxazol-2-yl) (POPOP), PSm5 pT and (1,4-bis [2-methylstyryl] benzene) (Bis-MSB), PSm6 with PPO, POPOP and naphthalene and PSm7 with pT, Bis-MSB and naphthalene. The synthesised plastic scintillation microspheres have been characterised in terms of their morphology, detection capabilities and alpha/beta separation capacity. The microspheres had a median diameter of approximately 130 μm. Maximum detection efficiency values were obtained for the PSm4 composition as follows 1.18% for 3 H, 51.2% for 14 C, 180.6% for 90 Sr/ 90 Y and 76.7% for 241 Am. Values of the SQP(E) parameter were approximately 790 for PSm4 and PSm5. These values show that the synthesised PSm exhibit good scintillation properties and that the spectra are at channel numbers higher than in commercial PSm. Finally, the addition

  9. Country report: Vietnam. Setting Up of a 90Sr/90Y Generator System Based on Supported Liquid Membrane (SLM) Technique and Radiolabeling of Eluted 90Y with Biomolecules

    International Nuclear Information System (INIS)

    Nguyen Thi Thu; Duong Van Dong; Bui Van Cuong; Chu Van Khoa

    2010-01-01

    In the course of participating in the IAEA-CRP during the last two years, Vietnam has achieved the goal of setting up a 90 Sr/ 90 Y generator system based on Supported Liquid Membrane (SLM) technique and also radiolabeling of the eluted 90 Y with antibody, peptides and albumin. A two stage SLM based 90 Sr- 90 Y generator was set up in-house to generate carrier-free 90 Y at different activity levels viz. 5, 20, 50 mCi. The generator system was operated in sequential mode in which 2-ethylhexyl 2-ethylhexyl phosphonic acid (PC88A) based SLM was used in the first stage for the transport 90 Y in 4.0 M nitric acid from source phase where 90 Sr- 90 Y equilibrium mixture is placed in nitric acid medium at pH to 1-2. In the second stage, octyl (phenyl)-N,N-diisobutylcarbamoylmethyl phosphine oxide (CMPO) based SLM was used for the transport of 90 Y selectively to 1.0 M acetic acid which is the best medium for radiolebeling. The eluted 90 Y from the generator was tested for the presence of any traces of 90 Sr using the Extraction Paper Chromatography (EPC) and was found suitable for radiolabeling. The generator system could be upgraded to 100 mCi level successfully due to an expert mission from India through IAEA. The 90 Y product obtained from the generator system was used for radiolabeling of antibody and peptides viz. Rituximab, DOTATATE and albumin particles under different experimental conditions. A new chromatography system could be developed for analyzing 90 Y labeled albumin using the TAE buffer as mobile phase in PC and ITLC

  10. Photoluminescence and lasing in whispering gallery mode glass microspherical resonators

    Energy Technology Data Exchange (ETDEWEB)

    Ristić, D. [Ruđer Bošković Institute, Division of Materials Physics, Laboratory for Molecular Physics, Bijenička c. 54, Zagreb (Croatia); Center of Excellence for Advanced Materials and Sensing Devices, Research unit New Functional Materials, Bijenička c. 54, Zagreb (Croatia); Berneschi, S.; Camerini, M. [IFAC-CNR Istituto di Fisica Applicata, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy); Farnesi, D.; Pelli, S. [IFAC-CNR Istituto di Fisica Applicata, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy); Centro Studi e Ricerche ' E. Fermi' , Piazza del Viminale 2, 00184 Roma (Italy); Trono, C. [IFAC-CNR Istituto di Fisica Applicata, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy); Chiappini, A.; Chiasera, A.; Ferrari, M. [CSMFO Group, Istituto di Fotonica e Nanotecnologie, IFN-CNR, Via alla Cascata 56/C, 38050 Povo-Trento (Italy); Lukowiak, A. [Institute of Low Temperature and Structure Research, PAS, ul. Okolna 2, Wroclaw 50-950 (Poland); Dumeige, Y.; Féron, P. [Laboratoire d' Optronique, (CNRS-UMR 6082-Foton), ENSSAT, 6 rue de Kérampont, 22300 Lannion (France); Righini, G.C. [IFAC-CNR Istituto di Fisica Applicata, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy); Centro Studi e Ricerche ' E. Fermi' , Piazza del Viminale 2, 00184 Roma (Italy); Soria, S., E-mail: s.soria@ifac.cnr.it [IFAC-CNR Istituto di Fisica Applicata, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy); Conti, G. Nunzi [IFAC-CNR Istituto di Fisica Applicata, Via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy); Centro Studi e Ricerche ' E. Fermi' , Piazza del Viminale 2, 00184 Roma (Italy)

    2016-02-15

    We report experimental results regarding the development of Er{sup 3+}-doped glass microspherical cavities for the fabrication of compact sources at 1.55 μm. We investigate several different approaches in order to fabricate the microspheres including direct melting of Er{sup 3+}-doped glass powders, synthesis of Er{sup 3+}-doped monolithic microspheres by drawing Er{sup 3+}-doped glass, and coating of silica microspheres with an Er{sup 3+}-doped sol–gel layer. Details of the different fabrication processes are presented together with the photoluminescence characterization in free space configuration of the microspheres and of the glass precursor. We have analyzed the photoluminescence spectra of the whispering gallery modes of the microspheres excited using evanescent coupling and we demonstrate tunable laser action in a wide range of wavelengths around 1.55 μm. As much as 90 μW of laser output power was measured in Er{sup 3+}-doped glass microspheres. - Highlights: • Different approaches in microsphere fabrication and various types of post-processing. • Trimming of photorefractive glass microsphere lasers with UV light. • Peak power record of 90 μW by pumping at 1480 nm.

  11. Radioembolization with Yttrium-90 microspheres for patients with unresectable hepatocellular carcinoma.

    Science.gov (United States)

    Bhangoo, Munveer Singh; Karnani, Diraj R; Hein, Paul N; Giap, Huan; Knowles, Harry; Issa, Chris; Steuterman, Steve; Pockros, Paul; Frenette, Catherine

    2015-10-01

    Hepatocellular carcinoma (HCC) is aggressive primary malignancy of the liver that most commonly presents late in the disease course. As a result, the majority of patients are not candidates for curative therapies. Locoregional therapies including Yttrium-90 (Y-90) radioembolization play an important role in management of the vast majority of patients with HCC. Patients with unnresectable HCC (n=17) treated with Y-90 radioembolization from 2005 to 2014 were evaluated retrospectively. Data was abstracted from medical records including patient charts, laboratory data, and imaging. Toxicities were recorded using Common Terminology Criteria 3.0. Response was recorded according to modified RECIST (mRECIST) criteria. Seventeen patients received 33 treatments with Y-90 radioembolization. A majority (65%) received TheraSphere with a minority (35%) receiving SIR-Spheres. The median treatment activity delivered was 1.725 gBq (range, 1.4-2.5 gBq). The median treatment dose delivered was 100 Gy (range, 90-120 Gy). The median lung shunt fraction was 2.02% (range, 1.5-4.1%). The most common clinical toxicity among all patients was nausea and vomiting (59%), primarily grade 1 and 2. Other post-treatment findings included abdominal pain (29%), fatigue (53%), and weight loss (18%). One patient developed a grade 5 gastric ulcer after the treatment. A clinical benefit, defined as patients achieving complete response (CR), partial response (PR) or stable disease (SD), was seen in 48% of patients. PR was seen in 24% of cases; progressive disease (PD) was noted in 35%. Patients survived for a median of 8.4 months (range, 1.3 to 21.1 months) after the first radioembolization treatment. Median survival after Y-90 treatment was 8.4 months among patients treated TheraSphere as compared with 7.8 months in patients treated with SIR-Spheres. The mean overall survival from the time of diagnosis was 11.7 months (range, 3.4 to 43.2 months). For patients with unresectable HCC, Y-90

  12. Treatment of metastasis localizations by intratumoral injection of radionuclide microsphere

    International Nuclear Information System (INIS)

    Tuo Peiyu; Pang Yan; Zhu Dianqing; Chang Keli; Zhu Yanjia

    2001-01-01

    Objective: To evaluate the therapeutic effects of radionuclide-labeled microsphere by intratumoral injection into 18 patients with superficial metastasis tumor for treatment. Methods: 18 patients with superficial metastasis were treated with radionuclide-labeled microsphere ( 90 Y-GTMS and 32 P-GTMS) by multi-point intratumoral injection. Each injection dose was 11.1-18.5 MBq/g (tumor). Results: 1 patient was relieved completely, 9 were relieved partly, 5 were improved and 3 kept stable. The total rate of relief and virtual value were 55.6% and 83.3% respectively. Conclusion: Topical treatment by using radionuclide may help diminish the tumor, control its progress and ease the symptoms. Thus it can be used as a supplement of routine treatment of tumors and it should do some work in therapy of malignant tumors in late stages

  13. Hepatic Toxicity After Radioembolization of the Liver Using {sup 90}Y-Microspheres: Sequential Lobar Versus Whole Liver Approach

    Energy Technology Data Exchange (ETDEWEB)

    Seidensticker, Ricarda; Seidensticker, Max; Damm, Robert; Mohnike, Konrad [Universitaetsklinikum Magdeburg, Klinik fuer Radiologie and Nuklearmedizin (Germany); Schuette, Kerstin; Malfertheiner, Peter [Universitaetsklinikum Magdeburg, Klinik fuer Gastroenterologie, Hepatologie und Infektiologie (Germany); Buskirk, Mark Van [Data Reduction (United States); Pech, Maciej; Amthauer, Holger; Ricke, Jens, E-mail: jens.ricke@med.ovgu.de [Universitaetsklinikum Magdeburg, Klinik fuer Radiologie and Nuklearmedizin (Germany)

    2012-10-15

    Purpose: {sup 90}Y-radioembolization (RE) is a promising technique for delivering high doses of radiation to liver tumors but may result in compromise of liver function. To gain further perspective, we evaluated the toxicity rates of sequential lobar versus 'whole liver' {sup 90}Y-radioembolization. Methods: Thirty-four patients with liver malignancy in noncirrhotic livers were included; {sup 90}Y-radioembolization was performed as either whole liver or sequential lobar treatment in 17 patients each. Standard clinical and liver specific laboratory parameters as well as MR imaging before treatment and at follow-up (6 and 12 weeks) after radioembolization were evaluated for toxicity using the Common Terminology Criteria for Adverse Events (CTCAE). Volumetry of the liver, tumor, and spleen and measurement of portal vein diameter also were performed. Results: Three months after whole liver RE, 14 liver-related grade 3/4 events were recorded versus 2 events after sequential lobar treatment (P < 0.05). Three patients treated with whole liver RE suffered from radioembolization-induced liver disease (REILD). Pathological increases in bilirubin at 3 months were observed for the whole liver group only (52.3 vs. 18.7 {mu}mol/l, P = 0.012). Total liver volume did not change significantly in either group, but shrinkage of the initially treated hepatic lobe with compensatory hypertrophy of the subsequently treated lobe was observed in the sequential lobar group (P < 0.05). Portal vein diameter increased significantly in whole liver-treated patients only (+17% vs. +6.6%, P = 0.043). Conclusions: Noncirrhotic patients undergoing sequential lobar radioembolization had less hepatic toxicity compared to whole liver embolization. The sequential approach should be the preferred strategy.

  14. Labeling of monoclonal antibody conjugates with 90Y

    International Nuclear Information System (INIS)

    Motta-Hennessy, Cecilia; Sharkey, R.M.; Goldenberg, D.M.

    1991-01-01

    An anti-carcinoembryonic antigen (CEA) antibody, NP-4, was labeled with 90 Y using p-isothiocyanatobenzyl DTPA (SCN-Bz-DTPA) and its derivatives 1-(p-isothiocyanatobenzyl)-3-methyl-DTPA (1B3M), 2-(p-isothiocyanatobenzyl)-4-methyl-DTPA (1M3B), 1-(2)-methyl-4-isothiocyanatobenzyl-DTPA (MX-DTPA) as the chelating agents. The 90 Y conjugates were purified from unbound 90 Y by two different methods, HPLC or acrylamide size exclusion gel chromatography, in order to evaluate the best purification method. Labeling efficiency, reaction kinetics and immunoreactivity were compared to the same antibodies labeled with [ 111 In]citrate. Labeling efficiency, as determined by either HPLC or ITLC (instant thin layer chromatography), was consistently higher by ITLC than HPLC for 90 Y-labeled MAb, but equal for 111 In-labeled MAbs. Discrepancies between the 2 methods were linked to impurities in the 90 Y that remained at the origin of ITLC plates. After purification by acrylamide gel filtration, recovery was 50-60% of loaded 90 Y activity, but was more than 87% for the 111 In compounds. Using HPLC, the recovery measured 85% for 90 Y-labeled MAb and more than 93% for 111 In-labeled conjugates. Immunoreactivity of the [ 90 Y]MAb was comparable to the 111 In-labeled conjugates. These studies indicate that HPLC purification of the [ 90 Y] MAbs improves recovery of activity, and suggests that impurities found in the 90 Y and metal-binding properties of acrylamide may have contributed to the poor recoveries from acrylamide gels. (author)

  15. Non-target activity detection by post-radioembolization yttrium-90 PET/CT: Image assessment technique and case examples

    Directory of Open Access Journals (Sweden)

    Yung Hsiang eKao

    2014-02-01

    Full Text Available High-resolution yttrium-90 (90Y imaging of post-radioembolization microsphere biodistribution may be achieved by conventional positron emission tomography with integrated computed tomography (PET/CT scanners that have time-of-flight capability. However, reconstructed 90Y PET/CT images have high background noise, making non-target activity detection technically challenging. This educational article describes our image assessment technique for non-target activity detection by 90Y PET/CT which qualitatively overcomes the problem of background noise. We present selected case examples of non-target activity in untargeted liver, stomach, gallbladder, chest wall and kidney, supported by angiography and 90Y bremsstrahlung single photon emission computed tomography with integrated computed tomography (SPECT/CT or technetium-99m macroaggregated albumin SPECT/CT.

  16. Molecular response assessed by {sup 68}Ga-DOTANOC and survival after {sup 90}Y microsphere therapy in patients with liver metastases from neuroendocrine tumours

    Energy Technology Data Exchange (ETDEWEB)

    Filippi, Luca; Salvatori, Rita; Bagni, Oreste [Santa Maria Goretti Hospital, Department of Nuclear Medicine, Latina (Italy); Scopinaro, Francesco [Sant' Andrea Hospital, Department of Nuclear Medicine, Rome (Italy); Pelle, Giuseppe; Cianni, Roberto [Santa Maria Goretti Hospital, Department of Interventional Radiology, Latina (Italy); Schillaci, Orazio [University Tor Vergata, Department of Biomedicine and Prevention, Rome (Italy)

    2016-03-15

    We investigated the prognostic role of {sup 68}Ga-DOTANOC in patients affected by hepatic metastases from neuroendocrine tumours (NET) undergoing {sup 90}Y radioembolization ({sup 90}Y-RE). A group of 15 consecutive patients with unresectable NET liver metastases underwent {sup 68}Ga-DOTANOC PET at baseline and 6 weeks after {sup 90}Y-RE. Molecular response was defined as a reduction of >50 % in the tumour-to-spleen ratio (ΔT/S). The patients were divided into two groups (responders with ΔT/S >50 % and nonresponders with ΔT/S <50 %) Patients were followed up by imaging and laboratory tests every 3 months until death or for at least 36 months following {sup 90}Y-RE. Statistical analysis was performed to identify factors predicting overall survival (OS) and progression-free survival (PFS). A decrease in T/S ratio was seen in all patients on {sup 68}Ga-DOTANOC PET scans performed after {sup 90}Y-RE. Nine patients were classified as responders and six as nonresponders. The mean OS in all patients was 31.0 months. Responders had a significantly (p < 0.001) longer OS (mean 36.0 ± 2.5 months) and PFS (mean 29.7 ± 3.4 months) than nonresponders. In a multivariate analysis, none of the other examined variables including age, unilobar vs. bilobar locations, bilirubin levels, radiological response or the presence of extrahepatic disease significantly predicted patient outcome. Molecular response assessed with {sup 68}Ga-DOTANOC PET might be a useful predictor of survival in patients affected by NET liver metastases treated with {sup 90}Y-RE. (orig.)

  17. Silicon microspheres for near-IR communication applications

    International Nuclear Information System (INIS)

    Serpengüzel, Ali; Demir, Abdullah

    2008-01-01

    We have performed transverse electric and transverse magnetic polarized elastic light scattering calculations at 90° and 0° in the o-band at 1.3 µm for a 15 µm radius silicon microsphere with a refractive index of 3.5. The quality factors are on the order of 10 7 and the mode/channel spacing is 7 nm, which correlate well with the refractive index and the optical size of the microsphere. The 90° elastic light scattering can be used to monitor a dropped channel (drop port), whereas the 0° elastic scattering can be used to monitor the transmission channel (through port). The optical resonances of the silicon microspheres provide the necessary narrow linewidths that are needed for high-resolution optical communication applications. Potential telecommunication applications include filters, modulators, switches, wavelength converters, detectors, amplifiers and light sources. Silicon microspheres show promise as potential building blocks for silicon-based electrophotonic integration

  18. Separation of 90Sr from Purex high level waste and development of a 90Sr-90Y generator

    International Nuclear Information System (INIS)

    Ramanujam, A.; Dhami, P.S.; Chitnis, R.R.; Achuthan, P.V.; Kannan, R.; Gopalakrishnan, V.; Balu, K.

    2000-04-01

    90 Y (T 1/2 =64.2 h) finds several applications in nuclear medicine. It is formed from the decay of 90 Sr which has a long half-life of 28.8 years. 90 Sr can be used as a long-lasting source for the production of carrier-free 90 Y. 90 Sr itself is abundantly available in high level waste (HLW) of PUREX origin. The present studies deal with the separation of pure 90 Sr from HLW and the subsequent separation of 90 Y from 90 Sr. Actinides and some of the fission products like lanthanides, zirconium, molybdenum and cesium were first removed from the HLW using methods based on solvent extraction and ion-exchange studied earlier in our laboratory. The resulting waste solution was used as a feed for the present process. The separation of 90 Sr from HLW was based on radiochemical method which involved a repeated scavenging with ferric hydroxide followed by strontium carbonate precipitation. The separation of 90 Y from 90 Sr was achieved by membrane separation technique. A compact generator is developed for this separation using a commercially available polytetrafluoroethylene (PTFE) membrane, impregnated with indigenously synthesised 2-ethylhexyl 2-ethylhexyl phosphonic acid (KSM-17). Generator system overcomes the drawbacks associated with conventional solvent extraction and ion-exchange based generators. The product is in chloride form and is suitable for complexation studies. After gaining an operating experience of ∼3 years in generating carrier-free 90 Y at 2 mCi level for initial studies in radiotherapeutic applications, the process was scaled up for the production of about 12 mCi of 90 Y to be used for animal studies before its application to patients. Radiochemical and chemical purity of the product was critically assayed by radiometry, ICP-AES, etc. The process is amenable for further scaling up. (author)

  19. Interstitial pituitary irradiation with 90Y for the treatment of acromomegaly

    International Nuclear Information System (INIS)

    Cassar, J.; Doyle, F.H.; Banks, L.M.; Jadresic, A.; Mashiter, K.; Joplin, G.F.

    1981-01-01

    The management of 54 acromegalics referred to us between 1974 and 1978 has been analysed. Twenty-two patients were treated with pituitary implants of yttrium-90 ( 90 Y). Eleven are in complete remission (mean growth hormone (GH) < 11 mlU/l), 8 had improved (mean GH 11-20 mlU/l or 50% less than preoperatively) and 3 were poor responders. Two patients had temporary 6th nerve paresis. Seven patients are on replacement therapy. Thirty- one patients were not implanted for the following reasons with a number of patients having more than one: extension of the tumour into the spehnoid sinus 10, or above the sella 3, partially empty sella 9, internal carotids too close to midline 2, invisible landmarks 1, mild acromegaly 6, poor general health 3, declined investigations or operation 6. It is concluded that pituitary implant of yttrium is an effective and safe form of treatment on carefully selected patients. (author)

  20. {sup 90}Y Production and Its Biodistribution in Mice; Pembuatan {sup 90}Y dan Biodistribusinya ke Mencit

    Energy Technology Data Exchange (ETDEWEB)

    Tri-Murni,; Cahyana,; Triyanto,; Djoharly,; Abidin,; Dede-K,; Karyadi, [Center for Development of Radioisotope and Radiopharmacentical(Indonesia)

    2001-11-15

    Yttrium - 90 is radioisotope emitting pure {beta} with maximum energy of 2.27 MeV while its average {beta} energy is 0.93 MeV. {sup 90}Y radioisotope was produced utilizing G.A Siwabessy reactor employing thermal neutron capture process. In nuclear medicine this radioisotope is utilized for bone mettastase palliative and curative therapies. Parameters in this research were the weight of natural Y{sub 2}O{sub 3} target, irradiation time in the reactor, radiochemical purity and specific activity. The end product of the process is YCl{sub 3}, in saline solution. Then sterility of the {sup 90}Y radioisotope so produced is tested and its biodistribution analysis results in mice organs show that the percentage of this radioisotope in the liver is much higher than the ones in heart, kidneys, lung and intestine. Therefore it is concluded that {sup 90}Y radioisotope in the form of YCl{sub 3} can be utilized as a radiopharmaceutical in nuclear medicine. (author)

  1. Radiolabeling Of Albumin Particles With Yttrium-90

    International Nuclear Information System (INIS)

    Nguyen Thi Thu; Nguyen Thi Khanh Giang; Bui Van Cuong, Vo Thi Cam Hoa

    2011-01-01

    This paper presents the process of the radiolabeling of microaggregated albumin particles with radionuclide Yttrium-90 using the directed method. The albumin microsphere kit was prepared in sodium phosphate buffer. The original solution includes 2 mg albumin particle and 0.5 mg stannous chloride dihydrate. The albumin particles size was ranged from 5 ?m to 30 ?m. The mixture was washed three times with phosphate buffer saline, pH 7.2 by centrifugation and suspended in 0.5 M sodium acetate buffer, pH 6. Yttrium - 90 in 1.0 M acetic acid was collected from 90 Sr/ 90 Y generator. The labeling of the particles with Y-90 (185 MBq) was performed at pH 5.5 in acetate buffer with agitating for 60 min at room temperature. The labeled albumin suspensions were centrifuged at 3000 rpm for 15 min. Labeling yields was calculated using centrifugation, filtration and compared with paper chromatography, which is developed in the Tris Acetic EDTA. In this system, the unbound of Y-90 migrates to an R f of 0.9-1.0 and the radiolabeled albumin particles remains at the point of origin (R f = 0). The size of 90 Y-albumin particles was compared with the albumin particles in the original solution to be sure that they did not change during the labeling treatment. The radiolabeling yields were more than 80%. The labeled compound was dialysis in phosphate buffer. The radiochemical purity was 98%. The 90 Y- albumin is an ideal radiopharmaceutical for potential use in malignant cancer treatment as brachytherapy. (author)

  2. Simulation Model of Microsphere Distribution for Selective Internal Radiation Therapy Agrees With Observations

    Energy Technology Data Exchange (ETDEWEB)

    Högberg, Jonas, E-mail: jonas.hogberg@radfys.gu.se [Department of Radiation Physics, Sahlgrenska Academy, University of Gothenburg, Gothenburg (Sweden); Rizell, Magnus [Department of Surgery, Sahlgrenska University Hospital, Gothenburg (Sweden); Hultborn, Ragnar; Svensson, Johanna [Department of Oncology, Sahlgrenska University Hospital, Gothenburg (Sweden); Henrikson, Olof [Department of Radiology, Sahlgrenska University Hospital, Gothenburg (Sweden); Mölne, Johan [Department of Pathology, Sahlgrenska University Hospital, Gothenburg (Sweden); Gjertsson, Peter [Department of Clinical Physiology, Sahlgrenska University Hospital, Gothenburg (Sweden); Bernhardt, Peter [Department of Radiation Physics, Sahlgrenska Academy, University of Gothenburg, Gothenburg (Sweden); Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg (Sweden)

    2016-10-01

    Purpose: To perform a detailed analysis of microsphere distribution in biopsy material from a patient treated with {sup 90}Y-labeled resin spheres and characterize microsphere distribution in the hepatic artery tree, and to construct a novel dichotomous bifurcation model for microsphere deposits and evaluate its accuracy in simulating the observed microsphere deposits. Methods and Materials: Our virtual model consisted of arteries that successively branched into 2 new generations of arteries at 20 nodes. The artery diameter exponentially decreased from the lowest generation to the highest generation. Three variable parameters were optimized to obtain concordance between simulations and measure microsphere distributions: an artery coefficient of variation (ACV) for the diameter of all artery generations and the microsphere flow distribution at the nodes; a hepatic tree distribution volume (HDV) for the artery tree; and an artery diameter reduction (ADR) parameter. The model was tested against previously measured activity concentrations in 84 biopsies from the liver of 1 patient. In 16 of 84 biopsies, the microsphere distribution regarding cluster size and localization in the artery tree was determined via light microscopy of 30-μm sections (mean concentration, 14 microspheres/mg; distributions divided into 3 groups with mean microsphere concentrations of 4.6, 14, and 28 microspheres/mg). Results: Single spheres and small clusters were observed in terminal arterioles, whereas large clusters, up to 450 microspheres, were observed in larger arterioles. For 14 microspheres/mg, the optimized parameter values were ACV=0.35, HDV = 50 cm{sup 3}, and ADR=6 μm. For 4.6 microspheres/mg, ACV and ADR decreased to 0.26 and 0 μm, respectively, whereas HDV increased to 130 cm{sup 3}. The opposite trend was observed for 28 microspheres/mg: ACV = 0.49, HDV = 20 cm{sup 3}, and ADR = 8 μm. Conclusion: Simulations and measurements reveal that microsphere clusters are

  3. Using Cherenkov Counting For Fast Determination of 90Sr/90Y Activity in Milk

    International Nuclear Information System (INIS)

    Tsroya, S.; Dolgin, B.; German, U.; Pelled, O.; Alfassi, Z. B.

    2014-01-01

    90Sr is one of the main long-lived fission products, and it is transferred into human body primarily by food, with milk being a substantial contributor. Due to its biochemical similarity to calcium, most strontium is efficiently incorporated into bone tissues. 90Sr is characterized by a long physical half life (28.8 y) and decays by beta particles with an Emax of 0.546 MeV to 90Y. This daughter isotope has a half life of 64 h and decays into 90Zr by beta particles with an Emax of 2.284 MeV. The milk components produce a high turbidity and light attenuation, causing a significant decrease of the counting efficiency in liquid scintillation counting (LSC) systems, mostly used for beta emitters detection. Most methods proposed in the past are time-consuming, as they are based on several stages of chemical and physical treatments, including precipitation, ashing, ion exchange and extraction (Wikins et al., 1984, Porter et al, 1961, Kimura et al., 1979). When measuring 90Sr/90Y activity by Cherenkov counting, most of the Cherenkov radiation is produced by 90Y (about 98.6%), due to the much higher energy of its beta particles relative to these from 90Sr. The counting efficiency varies strongly with color quenching, at a greater extent than in standard liquid scintillation counting (L'Annunziata, 2012), and therefore the quench correction is critical. The ‘‘external source area ratio’’ (ESAR) quench correction method was applied to measure 90Sr/90Y activities in aqueous samples with a wide range of quenching levels (Tsroya et al., 2009). This method was proved to be superior to all other quench correction methods (Tsroya et al., 2012) and is applicable also for determination of 90Sr/90Y in human urine (Tsroya et al., 2013). In the present work the applicability of the ESAR method to measurement of 90Sr/90Y activities in milk and some of its products was investigated

  4. Utilization of a novel electrochemical {sup 90}Sr/{sup 90}Y generator for the preparation of {sup 90}Y-labeled RGD peptide dimer in clinically relevant dose

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, Sudipta; Chakravarty, Rubel; Pillai, Maroor Raghavan Ambikalmajan; Dash, Ashutosh [Bhabha Atomic Research Centre, Mumbai (India). Radiopharmaceuticals Div.; Sarma, Haladhar Dev [Bhabha Atomic Research Centre, Mumbai (India). Radiation Biology and Health Sciences Div.

    2014-09-01

    The work reported in this paper provides a systematic study towards the development of an optimized strategy for preparation of a clinically relevant dose of {sup 90}Y-labeled dimeric RGD peptide derivative, DOTA-E[c(RGDfK)]{sub 2} [DOTA-(RGD){sub 2}] for in vivo targeted therapy utilizing {sup 90}Y obtained from a novel electrochemical {sup 90}Sr/{sup 90}Y generator. The performance of the generator was evaluated to ensure its suitability for providing {sup 90}Y in adequate quantity and purity required for formulation of clinically relevant dose for PRRT. {sup 90}Y-DOTA-(RGD){sub 2} was synthesized in high yield (86.2 ± 2.5%) and radiochemical purity (98.4 ± 0.5%) using clinically relevant dose (∝ 3.8 GBq) of {sup 90}Y. In vitro stability studies revealed that the radiolabeled conjugate retained its radiochemical purity in normal saline and human serum. Preliminary biodistribution studies carried out in C57/BL6 mice bearing melanoma tumors showed that the preparation exhibited significant tumor uptake (5.30 ± 0.78% of injected activity at 30 min post-injection) with good tumor to background ratio. The optimized radiolabeling protocol seems to be an attractive strategy which is largely viewed as a springboard to realize scope of developing {sup 90}Y labeled cyclic RGD peptides for targeted therapy of tumors over-expressing integrin-α{sub ν}β{sub 3} receptors. (orig.)

  5. Evaluation of factors affecting tumor response and survival in patients with primary and metastatic liver cancer treated with microspheres.

    Science.gov (United States)

    Demirelli, Serkan; Erkilic, Metin; Oner, Ali Ozan; Budak, Evrim Surer; Gunduz, Seyda; Ozgur, Ozhan; Bozcuk, Hakan; Sindel, Hakki Timur; Boz, Adil

    2015-04-01

    Radioembolization with the yttrium-90 (Y-90) microspheres is being used increasingly more often in the treatment of patients with primary or metastatic liver cancer. Although technetium-99m macroaggregated albumin (Tc-99m MAA) scintigraphy performed following diagnostic angiography has an important role in predicting the effectiveness of treatment and in dose estimation, the number of studies using quantitative assessment of Tc-99m MAA scintigraphy is limited in this field. In the present study, the aim was to assess whether a tumor dose is required to obtain objective tumor response and to check whether this threshold value is predictive in terms of tumor response, survival, and liver toxicity by using Tc-99m MAA single-photon emission computed tomography (SPECT) images. Overall, 54 patients (20 women and 34 men; median age: 60 years) who underwent Y-90 Resin (SIR-Spheres) and Glass (TheraSphere) microsphere treatment with a diagnosis of unresectable liver cancer between August 2010 and April 2013 were included in the study. The mean doses to normal liver and tumor were estimated for each patient using Tc-99m MAA SPECT images and the medical internal radiation dosimetry method. The responses were assessed according to Response Evaluation Criteria In Solid Tumors (RECIST) and European Organisation for Research and Treatment of Cancer (EORTC) criteria. Kaplan-Meier survival curves and univariate Cox regression analysis were used in survival analysis. The relationship between treatment response and other parameters included was assessed using logistic regression analysis. The variables with a P value less than 0.01 in univariate analysis were assessed with multivariate analysis. Fifty-four Y-90 microsphere treatments (eight by using a Y-90 glass microsphere and 46 by using a Y-90 resin microsphere) were performed. In the multivariate analysis, the only parameter related to response was tumor dose (P<0.01). With a tumor dose of 280 Gy or higher, objective tumor

  6. A special mini-extrapolation chamber for calibration of 90Sr+90Y sources

    International Nuclear Information System (INIS)

    Oliveira, Mercia L; Caldas, Linda V E

    2005-01-01

    90 Sr+ 90 Y applicators are commonly utilized in brachytherapy, including ophthalmic procedures. The recommended instruments for the calibration of these applicators are extrapolation chambers, which are ionization chambers that allow the variation of their sensitive volume. Using the extrapolation method, the absorbed dose rate at the applicator surface can be determined. The aim of the present work was to develop a mini-extrapolation chamber for the calibration of 90 Sr+ 90 Y beta ray applicators. The developed mini-chamber has a 3.0 cm outer diameter and is 11.3 cm in length. An aluminized polyester foil is used as the entrance window while the collecting electrode is made of graphited polymethylmethacrylate. This mini-chamber was tested in 90 Sr+ 90 Y radiation beams from a beta particle check source and with a plane ophthalmic applicator, showing adequate results

  7. Verification dosimetry of intravascular 90Sr/90Y source trains

    International Nuclear Information System (INIS)

    Sharma, S.D.; Shanta, A.; Tripathi, U.B.; Bhatt, B.C.

    2001-01-01

    90 Sr/ 90 Y source trains (Novoste Beta-Cath System) are currently under clinical trials in India and abroad for intracoronary brachytherapy for prevention of restenosis. Each source train of the Beta-Cath system is supplied with a source certificate giving dose rate at the reference distance of 2 mm from the centerline of the source train. It is essential that the user should check dose rates of brachytherapy sources before its application on the patients. Dose rates and depth dose measurements for 90 Sr/ 90 Y source trains of active length 40 mm using radiochromic films in a tissue equivalent phantom have been carried out. The objectives of these measurements were (1) to verify the dose rates stated in the source certificate, and (2) to obtain relative depth dose data for treatment planning. This paper presents the results of these measurements

  8. Country report: Vietnam. Setting Up of a {sup 90}Sr/{sup 90}Y Generator System Based on Supported Liquid Membrane (SLM) Technique and Radiolabeling of Eluted {sup 90}Y with Biomolecules

    Energy Technology Data Exchange (ETDEWEB)

    Thu, Nguyen Thi; Dong, Duong Van; Cuong, Bui Van; Khoa, Chu Van [Vietnam Atomic Energy Commission (VAEC), Nuclear Research Institute, Dalat (Viet Nam)

    2010-07-01

    In the course of participating in the IAEA-CRP during the last two years, Vietnam has achieved the goal of setting up a {sup 90}Sr/{sup 90}Y generator system based on Supported Liquid Membrane (SLM) technique and also radiolabeling of the eluted {sup 90}Y with antibody, peptides and albumin. A two stage SLM based {sup 90}Sr-{sup 90}Y generator was set up in-house to generate carrier-free {sup 90}Y at different activity levels viz. 5, 20, 50 mCi. The generator system was operated in sequential mode in which 2-ethylhexyl 2-ethylhexyl phosphonic acid (PC88A) based SLM was used in the first stage for the transport {sup 90}Y in 4.0 M nitric acid from source phase where {sup 90}Sr-{sup 90}Y equilibrium mixture is placed in nitric acid medium at pH to 1-2. In the second stage, octyl (phenyl)-N,N-diisobutylcarbamoylmethyl phosphine oxide (CMPO) based SLM was used for the transport of {sup 90}Y selectively to 1.0 M acetic acid which is the best medium for radiolebeling. The eluted {sup 90}Y from the generator was tested for the presence of any traces of {sup 90}Sr using the Extraction Paper Chromatography (EPC) and was found suitable for radiolabeling. The generator system could be upgraded to 100 mCi level successfully due to an expert mission from India through IAEA. The {sup 90}Y product obtained from the generator system was used for radiolabeling of antibody and peptides viz. Rituximab, DOTATATE and albumin particles under different experimental conditions. A new chromatography system could be developed for analyzing {sup 90}Y labeled albumin using the TAE buffer as mobile phase in PC and ITLC.

  9. Labeling of monoclonal antibody conjugates with sup 90 Y

    Energy Technology Data Exchange (ETDEWEB)

    Motta-Hennessy, Cecilia; Sharkey, R.M.; Goldenberg, D.M. (Center for Molecular Medicine and Immunology, Newark, NJ (USA))

    1991-01-01

    An anti-carcinoembryonic antigen (CEA) antibody, NP-4, was labeled with {sup 90}Y using p-isothiocyanatobenzyl DTPA (SCN-Bz-DTPA) and its derivatives 1-(p-isothiocyanatobenzyl)-3-methyl-DTPA (1B3M), 2-(p-isothiocyanatobenzyl)-4-methyl-DTPA (1M3B), 1-(2)-methyl-4-isothiocyanatobenzyl-DTPA (MX-DTPA) as the chelating agents. The {sup 90}Y conjugates were purified from unbound {sup 90}Y by two different methods, HPLC or acrylamide size exclusion gel chromatography, in order to evaluate the best purification method. Labeling efficiency, reaction kinetics and immunoreactivity were compared to the same antibodies labeled with ({sup 111}In)citrate. Labeling efficiency, as determined by either HPLC or ITLC (instant thin layer chromatography), was consistently higher by ITLC than HPLC for {sup 90}Y-labeled MAb, but equal for {sup 111}In-labeled MAbs. Discrepancies between the 2 methods were linked to impurities in the {sup 90}Y that remained at the origin of ITLC plates. After purification by acrylamide gel filtration, recovery was 50-60% of loaded {sup 90}Y activity, but was more than 87% for the {sup 111}In compounds. Using HPLC, the recovery measured 85% for {sup 90}Y-labeled MAb and more than 93% for {sup 111}In-labeled conjugates. Immunoreactivity of the ({sup 90}Y)MAb was comparable to the {sup 111}In-labeled conjugates. These studies indicate that HPLC purification of the ({sup 90}Y) MAbs improves recovery of activity, and suggests that impurities found in the {sup 90}Y and metal-binding properties of acrylamide may have contributed to the poor recoveries from acrylamide gels. (author).

  10. Radiochemistry, pre-clinical studies and first clinical investigation of 90Y-labeled hydroxyapatite (HA) particles prepared utilizing 90Y produced by (n,γ) route

    International Nuclear Information System (INIS)

    Vimalnath, K.V.; Chakraborty, Sudipta; Rajeswari, A.; Sarma, H.D.; Nuwad, Jitendra; Pandey, Usha; Kamaleshwaran, K.; Shinto, Ajit; Dash, Ashutosh

    2015-01-01

    Introduction: The scope of using no carrier added (NCA) 90 Y [T 1/2 = 64.1 h, E β(max) = 2.28 MeV] obtained from 90 Sr/ 90 Y generator in radiation synovectomy (RSV) is widely accepted. In the present study, the prospect of using 90 Y produced by (n,γ) route in a medium flux research reactor for use in RSV was explored. Methods: Yttrium-90 was produced by thermal neutron irradiation of Y 2 O 3 target at a neutron flux of ~ 1 × 10 14 n/cm 2 .s for 14 d. The influence of various experimental parameters were systematically investigated and optimized to arrive at the most favorable conditions for the formulation of 90 Y labeled hydroxyapatite (HA) using HA particles of 1–10 μm size range. An optimized kit formulation strategy was developed for convenient one-step compounding of 90 Y-HA, which is easily adaptable at hospital radiopharmacy. The pre-clinical biological evaluation of 90 Y-HA particles was studied by carrying out biodistribution and bioluminiscence imaging studies in Wistar rats. The first clinical investigation using the radiolabeled preparation was performed on a patient suffering from chronic arthritis in knee joint by administering 185 MBq 90 Y-HA formulated at the hospital radiopharmacy deploying the proposed strategy. Results: Yttrium-90 was produced with a specific activity of 851 ± 111 MBq/mg and radionuclidic purity of 99.95 ± 0.02%. 90 Y-labeled HA particles (185 ± 10 MBq doses) were formulated in high radiochemical purity (> 99%) and excellent in vitro stability. The preparation showed promising results in pre-clinical studies carried out in Wistar rats. The preliminary results of the first clinical investigation of 90 Y-HA preparation in a patient with rheumatoid arthritis in knee joints demonstrated the effectiveness of the formulation prepared using 90 Y produced via (n,γ) route in the management of the disease. Conclusion: The studies revealed that effective utilization of 90 Y produced via (n,γ) route in a medium flux research

  11. Polymer based microspheres of aceclofenac as sustained release parenterals for prolonged anti-inflammatory effect

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, Manpreet; Sharma, Sumit; Sinha, VR, E-mail: sinha_vr@rediffmail.com

    2017-03-01

    Poly(lactic-co-glycolic acid) (PLGA) (75:25) and polycaprolactone (PCL) microspheres were fabricated for prolonged release of aceclofenac by parenteral administration. Microspheres encapsulating aceclofenac were designed to release the drug at controlled rate for around one month. Biodegradable microspheres were prepared by solvent emulsification evaporation method in different polymer:drug ratios (1:1, 2:1 and 3:1). After drug loading, PLGA and PCL microspheres showed a controlled size distribution with an average size of 11.75 μm and 3.81 μm respectively and entrapment efficiency in the range of 90 ± 0.72% to 91.06 ± 4.01% with PLGA and 83.01 ± 2.13% to 90.4 ± 2.11% with PCL. Scanning electron microscopy has confirmed good spherical structures of microspheres. The percent yield of biodegradable polymeric microspheres ranged between 30.95 ± 10.14% to 92.84 ± 3.15% and 47.33 ± 4.72% to 80 ± 3.60% for PLGA and PCL microspheres respectively. PLGA microspheres followed Higuchi release pattern while Korsmeyer-Peppas explained the release pattern of PCL microspheres. Stability studies of microspheres were also carried out by storing the preparations at 2-8 °C for 30, 60 and 90 days and evaluating them for entrapment efficiency, residual drug content and polymer drug compatability. In-vivo studies showed significant anti-inflammatory activity of microspheres upto 48 hours using the carrageenan induced rat paw oedema model. - Highlights: • PLGA and PCL polymeric microspheres for parenteral prolonged drug delivery system were formulated. • Polymeric microspheres were characterized physically and drug excipient incompatability. • Three months accelerated stability studies were carried for drug loaded polymeric microspheres. • Pharmacodynamic studies prove the rationality of sustained therapeutic effect of designed drug delivery system.

  12. Synthesis of Y2O2S:Eu3+, Mg2+, Ti4+ hollow microspheres via homogeneous precipitation route

    Directory of Open Access Journals (Sweden)

    Peng-Fei Ai, Ying-Liang Liu, Li-Yuan Xiao, Hou-Jin Wang and Jian-Xin Meng

    2010-01-01

    Full Text Available A phosphorescent material in the form of Y2O2S:Eu3+, Mg2+, Ti4+ hollow microspheres was prepared by homogeneous precipitation using monodispersed carbon spheres as hard templates. Y2O3:Eu3+ hollow microspheres were first synthesized to serve as the precursor. Y2O2S:Eu3+, Mg2+, Ti4+ powders were obtained by calcinating the precursor in a CS2 atmosphere. The crystal structure, morphology and optical properties of the composites were characterized. X-ray diffraction measurements confirmed the purity of the Y2O2S phase. Electron microscopy observations revealed that the Y2O2S:Eu3+, Mg2+, Ti4+ particles inherited the hollow spherical shape from the precursor after being calcined in a CS2 atmosphere and that they had a diameter of 350–450 nm and a wall thickness of about 50–80 nm. After ultraviolet radiation at 265 or 325 nm for 5 min, the particles emitted strong red long-lifetime phosphorescence originating from Eu3+ ions. This phosphorescence is associated with the trapping of charge carriers by Ti4+ and Mg2+ ions.

  13. A model for dose estimation in therapy of liver with intraarterial microspheres

    International Nuclear Information System (INIS)

    Zavgorodni, S.F.

    1996-01-01

    Therapy with intraarterial microspheres is a technique which involves incorporation of radioisotope-labelled microspheres into a capillary bed of tumour and normal tissue. Beta-emitters such as 90 Y and 166 Ho are used for this purpose. This technique provides tumour to normal tissue (TNT) dose ratios in the range of 2-10 and demonstrates significant clinical benefit, which could potentially be increased with more accurate dose predictions and delivery. However, dose calculations in this modality face the difficulties associated with nonuniform and inhomogeneous activity distribution. Most of the dose calculations used clinically do not account for the nonuniformity and assume uniform activity distribution. This paper is devoted to the development of a model which would allow more accurate prediction of dose distributions from microspheres. The model calculates dose assuming that microspheres are aggregated into randomly distributed clusters, and using precomputed dose kernels for the clusters. The dose kernel due to a microsphere cluster was found by numerical integration of a point source dose kernel over the volume of the cluster. It is shown that a random distribution of clusters produces an intercluster distance distribution which agrees well with the one measured by Pillai et al in liver. Dose volume histograms (DVHs) predicted by the model agree closely with the results of Roberson et al for normal tissue and tumour. Dose distributions for different concentrations and types of radioisotope, as well as for tumours of different radii, have been calculated to demonstrate the model's possible applications. (author)

  14. Study of radionuclide 90Sr-90Y on cell proliferation and apoptosis in benign prostatic hyperplasia

    International Nuclear Information System (INIS)

    Zhang Tong; Wei Wei; Zou Benjie; Liu Fang; Xu Zhishun

    2003-01-01

    Objective: To investigate the effect of 90 Sr- 90 Yon cell proliferation and apoptosis in benign prostatic hyperplasia. Methods: The apoptosis and expression of Ki-67 in benign prostatic hyperplasia (BPH) before and after irradiation 90 Sr- 90 Y were detected by transferase-mediated dUTP-biotin nick end labeling (TUNEL) method and immunohistochemical technique, respectively. Results: The proliferation index (PI) of BPH after 90 Sr- 90 Y irradiation was much lower than that before irradiation, but there was no significant change in apoptosis index (AI). Conclusion: Irradiation with 90 Sr- 90 Y could restrain cell proliferation of BPH, but could not induce apoptosis

  15. Internal Dosimetry in therapy with 90Y

    International Nuclear Information System (INIS)

    Torres, Leonel; Vergara, Alex; García, Leonardo

    2016-01-01

    Introduction: 90 Y has shown satisfactory results in the therapy of multiple oncological diseases. This radionuclide has been widely used in therapy of diseases such as NHL (Zevalin), TNE ( 90 Y-DOTATOC), liver cancer, etc. Its safe and effective use presupposes the availability of accurate dosimetry methods and reproducible.El objective of this work is to standardize and optimize images use procedures that allow for dosimetric estimates braking during therapy of malignant diseases 90 Y. Materials and Methods: To quantify the activity in absolute units from scans correction methods that consider the peculiarities of the bremsstrahlung of 90 Y were proposed. acquisition parameters such as the selection of the collimator and the definition of energy windows as well as methods of scatter correction, attenuation, interactions of radiation with the collimator (septal penetration and degradation of information with distance) were considered and sensitivity or calibration factor was estimated. They were evaluated and calibrated parameters for dosimetry at the level of organ and estimates of distributions 3D dose, using experimental measurements with SPECT Mediso Nucline ™ Spirit DH-V system and simulations were performed using the Monte Carlo method, using the SIMIND v5 software .0. Results: The optimum position-energy window width and collimator to be used is determined from the relationship between total photons and primary photons (T / P), calculated with SIMIND. The results were favorable to employ HEGP collimator and energy window between 90-170kev. the sensitivity of the system for the selected collimator (HEGP for 90 Y) was estimated. He was evaluated and determined the MTF order to correct dispersive plane images, the source-detector and interactions of radiation with the collimator distance, using filtering methods (Wiener filter), including empirical estimates of the SNR component. Similarly the procedure for the use of transmission maps obtained from

  16. Rapid determination of 90Sr impurities in freshly 'generator eluted'90Y for radiopharmaceutical preparation

    International Nuclear Information System (INIS)

    Bonardi, Mauro L.; Martano, Luigi; Groppi, Flavia; Chinol, Marco

    2009-01-01

    90 Y is one of the most useful radionuclides for radioimmunotherapeutic applications and has a half-life (t 1/2 =64.14 h) suitable for most therapeutic applications, beta particles of high energy and decays to a stable daughter. It is significant that 90 Y is available conveniently and inexpensively from a radionuclide 'generator' by decay of its parent, 90 Sr. Nevertheless, current and planned clinical applications with [ 90 Y] labelled compounds employ activity levels that cannot be readily obtained from an in-house generator, but from commercial sources. We have evaluated Eichrom's Sr-resin, either as an 'in-house' generator or as a fast QC method for analysis of 90 Y solutions. In particular, for the development as a generator, we investigated the percentage of the radio-Sr in the first 8 M HNO 3 eluate: in this fraction the concentration of 90 Sr must be smaller than 10 -5 % (recommendations of the International Commission on Radiological Protection). For evaluation as a rapid QC method, we analyzed the concentration of 90 Y in all the fractions containing 'only' radio-Sr: 90 Y should not be present in these eluates. After the collection of β - and γ spectra and analysis of them, we concluded that commercial Sr-resin minicolumn cannot give us the results expected; we developed an in-house system loaded with 4 mL of Sr-resin which gave better results as a generator and a rapid QC method.

  17. Quantitative measurement of Y90 brehmmstrahlung images after of Y90 Sir-Spheres implantation to assess lung shunting

    International Nuclear Information System (INIS)

    Forwood, Nicholas J.; Pocock, Nicholas; Shin, Jane; Young, Andy M; Szeto, Edwin R.

    2009-01-01

    Full text: Background: In clinical practice the dose of Y 9 0 Sir-Spheres is calculated using a pre injection of Tc 9 9 m MAA. There is however a potential difference due to the different properties of Tc 9 9 m MAA and Y 9 0 Sir-Spheres. We assessed the concordance of lung shunting of Y 9 0 Sir-Spheres estimated using Y 9 0 Bremsstrahlung imaging, compared to shunting assessed using Tc 9 9 m MAA. Methods: 15 Patients were evaluated using 150-200 MBq of Tc 9 9 m MAA injected into the hepatic artery under angiographic guidance. Whole body images were acquired using a LEAP collimator (window of 140 kEv+/-10%). The patients were subsequently treated with Y 9 0 Sir-Spheres. After microspheres injection, whole body brehmsstrahlung images were acquired using a medium energy collimator (window settings of 75 kEv +/- 20%). Tc 9 9 m MAA images were paired with their corresponding bremsstrahlung image and lung shunting in the stu ides calculated simultaneously. Each paired dataset was analyzed by 5 operators. Results: The mean lung shunting for Tc 9 9 m MAA acquisition was 3.32% (SD 2.03) which was significantly lower than the lung shunting using the Y 9 0 acquisitions: mean 16.19% (SD of 6.43). The Pearson coefficient was r = 0.62 (p 9 0 Sir-Spheres bremsstrahlung imaging is higher than that calculated by Tc 9 9 m MAA imaging. The relationship is not sufficiently strong to use bremsstahlung imaging to retrospectively quantify the lung-to-liver shunting as indicated using Tc 9 9 M AA. Further studies are underway to assess the reliability of Tc 9 9 m MAA lung uptake calculations in determining the dose of Y 9 0 Sir-Spheres.

  18. Electrochemical separation of 90-yttrium in the electrochemical 90Sr/90Y generator and its use for radiolabelling of DOTA-conjugated somatostatin analog [DOTA0, Tyr3] octreotate

    Directory of Open Access Journals (Sweden)

    Petrović Đorđe Ž.

    2012-01-01

    Full Text Available Radiopharmaceuticals based on 90Y are widely used in the treatment of malignant deseases. In order to meet the requirements for their future application, a 90Sr/90Y generator was developed and 90Y eluted from this locally produced generator was used for the radiolabelling of the DOTA-conjugated somatostatin analog [DOTA0,Tyr3] octreotate and the preparation of [90Y-DOTA0,Tyr3] octreotate (90Y-DOTATATE for peptide receptore radionuclide therapy. 90Sr/90Y generator was based on the electrochemical separation of 90Y from 90Sr in a two-cycle electrolysis procedure. Three electrode cells were used to perform both electrolyses. In both cycles, working electrodes were kept on constant potential. The pH of the solution was adjusted to 2.7 of the value before the electrolyses. The radionuclidic purity of the 90Y solution was analysed by ITLC and extraction paper chromatography. The labelling of peptide (100 mg DOTATATE with 90YCl3 was performed at 95°C for 30 minutes. Radiochemical purity was determined by HPLC and chromatographic separation, using a solid SepPak C-18 column. Results obtained confirmed the efficiency of our electrochemical separation technique and quality control methods for 90Y. The achieved efficiency of the 90Sr/90Y generator above 96% of the theoretical value represents a good basis for the further development of this generator. The labelling of the DOTATATE with 90Y exhibited a high efficiency, too: there was less than 1% of 90Y3+in the 90Y-DOTATATE.

  19. Calibration of the 90Sr+90Y ophthalmic and dermatological applicators with an extrapolation ionization minichamber

    International Nuclear Information System (INIS)

    Antonio, Patrícia L.; Oliveira, Mércia L.; Caldas, Linda V.E.

    2014-01-01

    90 Sr+ 90 Y clinical applicators are used for brachytherapy in Brazilian clinics even though they are not manufactured anymore. Such sources must be calibrated periodically, and one of the calibration methods in use is ionometry with extrapolation ionization chambers. 90 Sr+ 90 Y clinical applicators were calibrated using an extrapolation minichamber developed at the Calibration Laboratory at IPEN. The obtained results agree satisfactorily with the data provided in calibration certificates of the sources. - Highlights: • 90 Sr+ 90 Y clinical applicators were calibrated using a mini-extrapolation chamber. • An extrapolation curve was obtained for each applicator during its calibration. • The results were compared with those provided by the calibration certificates. • All results of the dermatological applicators presented lower differences than 5%

  20. Enrichment and determination of small amounts of 90Sr/90Y in water samples

    International Nuclear Information System (INIS)

    Mundschenk, H.

    1979-01-01

    Small amounts of 90 Sr/ 90 Y can be concentrated from large volumes of surface water (100 l) by precipitation of the phosphates, using bentonite as adsorber matrix. In the case of samples containing no or nearly no suspended matter (tap water, ground water, sea water), the daughter 90 Y can be extracted directly by using filter beds impregnated with HDEHP. The applicability of both techniques is demonstrated under realistic conditions. (orig.) 891 HP/orig. 892 MKO [de

  1. Dosimetric comparison of electron beam and 90Sr+90Y applicator for keloids treatment

    International Nuclear Information System (INIS)

    Coelho, Talita S.; Tada, Ariane; Antonio, Patricia L.; Yoriyaz, Helio; Fernandes, Marco A.R.

    2009-01-01

    Studies have been shown that among several methods that have been used for the treatment of keloids the surgical excision followed by the adjuvant radiotherapy presents the lowest relapsed rate of the injury. In this work a comparative dosimetric study has been performed using a 4 MeV electron beam from a Varian Clinac 2100C linear accelerator at the radiotherapy service of the Hospital das Clinicas of UNESP-HC, Botucatu-SP and an Amershan 90 Sr+ 90 Y brachytherapy applicator with 1491 MBq of activity. Percentage depth dose curves from ionization chamber measurements and through Monte Carlo simulation have been obtained and compared. Dose measurements have been obtained using parallel plates ionization chamber (Esradin A12) and extrapolation mini-chamber developed at IPEN. The dose calculations have been obtained using the well-known Monte Carlo radiation transport code MCNP-4C. Maximum dose differences obtained between measured/calculated values for 90 Sr+ 90 Y applicator and for the electron beam were, respectively: 7.8 % and 8.0%. The profiles of the depth and superficial tissue dose distribution produced by the electron beam revealed themselves flatter and more homogeneous than those produced by the 90 Sr+ 90 Y applicator, especially to wider fields, which cannot be obtained with beta therapy applicators because of their geometric limitations. In conclusion this present work has shown that 90 Sr+ 90 Y applicators could be efficient for small and very superficial lesions but in most cases electron beam sources are more adequate especially for large and deeper lesions. (author)

  2. Right Gastric Artery Embolization Prior to Treatment with Yttrium-90 Microspheres

    International Nuclear Information System (INIS)

    Cosin, Octavio; Bilbao, Jose Ignacio; Alvarez, Sergio; Luis, Esther de; Alonso, Alberto; Martinez-Cuesta, Antonio

    2007-01-01

    Purpose. Intra-arterial infusion of yttrium-90 microspheres is a form of radiation treatment for unresectable hepatic neoplasms. Misdeposition of particles in the gastroduodenal area such as the right gastric artery (RGA) may occur with serious consequences. We present a series of patients who underwent a detailed vascular study followed by RGA embolization. Special emphasis is placed on anatomic variations and technical considerations .Methods. In a 1 year period, 27 patients were treated. Initial vascular evaluation was performed, with careful attention to anatomic variants or extrahepatic arterial supply, especially to the gastroduodenal area. Embolization of such arteries was planned if needed. RGA embolization was performed antegradely from the hepatic artery or retrogradely via the left gastric artery (LGA). Postprocedural follow-up included clinical interview and gastroscopy if necessary. Results. RGA embolization was performed in 9 patients presenting with primary (n = 3) or metastatic liver tumors (n 6). Six patients underwent antegrade RGA embolization and 3 had embolization done retrogradely via the LGA. Retrograde access was chosen for anatomic reasons. None of the patients complained of gastroduodenal symptoms. Conclusion. RGA embolization can help minimize the gastroduodenal deposition of radioactive particles. RGA embolization should routinely be carried out. The procedure can be performed, with similar technical success, by both anterograde and retrograde approaches

  3. Hepatobiliary effects of 90yttrium microsphere therapy for unresectable hepatocellular carcinoma.

    Science.gov (United States)

    Nalesnik, Michael A; Federle, Michael; Buck, David; Fontes, Paulo; Carr, Brian I

    2009-01-01

    (90)Yttrium (Therasphere) microspheres administered via hepatic artery are a valuable option for treatment of hepatocellular carcinoma. This therapy targets tumor nodules while largely sparing hepatic parenchyma. This retrospective study examines liver explants from 13 adult patients with hepatocellular carcinoma who received intrahepatic Theraspheres and subsequently underwent liver transplantation. Histopathologic and laboratory reviews are performed. Theraspheres preferentially migrated to the lobe(s) supplied by the injected artery branches and frequently localized to tumors. Tumors showed a chronology of changes beginning with confluent necrosis typically accompanied by hemorrhage and later by fibrinoid change. This was followed by fibrosis with regenerative activity at tumor peripheries. Adjacent hepatic parenchyma went through a similar sequence of injury and repair that could lead to markedly fibrotic cirrhotic nodules in the vicinity of treated tumors. No consistent pattern of thrombomodulin loss was seen in endothelial cells of the tumors or adjacent parenchyma, suggesting that direct endothelial cell injury was likely not a major contributor to the necrotic process. However, the pattern of injury and repair is suggestive of a localized and subclinical form of radiation-induced liver disease. The pathologist should be aware of these changes to distinguish them from the diffuse "radiation hepatitis" associated with older forms of radiotherapy.

  4. Development of Technology for the Preparation of 90Sr/90Y Generators at the Radiopharmacy Directory of IPEN/CNEN-SP

    International Nuclear Information System (INIS)

    Barrio, Graciela

    2010-01-01

    90 Y (T /2 = 2,67 d; Eβmax = 2,28 MeV) is a radionuclide with efficacy established for various cancer therapies, labeling biomolecules and treating of radiosinovectomy. Due to its nuclear properties, is obtained through the decay of 90 Sr T /2 = 28 y in the form of a generator. Several types of 90 Sr/ 90 Y generators were developed, and the most employed are the cation exchange resins, where Sr and Y are adsorbed and 90 Y is selectively eluted with acetate or EDTA. The disadvantage of this type of generator is the radiolysis, which degrades its use. The electrochemical generator is a proposed solution because there is no significant effect of radiation. In this concept, the difference between the electrochemical potentials of the elements Sr and Y is used to obtain a rapid separation of 90 Y from 90 Sr. The production of 90 Y via colloid formation is the simplest method for the separation, based on the colloid formation of Y in high alkaline pH, which can be filtered and separated from Sr, and subsequently dissolved in HCl. The objective of this work was the development of technologies for the preparation of 90 Sr/ 90 Y generators, and three technologies were developed: generators using cation resins columns, generators through colloid formation and electrochemical generators. Radionuclidic quality control of 90 Y was also evaluated by liquid scintillation, radionuclide identity, extraction paper chromatography (EPC) using complexing agents for 90 Y and by Optical Emission Spectrometry with Inductively Coupled Plasma (ICP-OES). The results showed that generators using cation resins have the best results related to the elution efficiency (∼83%), the reproducibility and radionuclidic purity. The electrochemical generator showed a potential for development, having the advantage of not suffering the effects of radiolysis of the pair 90 Sr/ 90 Y as the resin. A comparison and evaluation of the methods of the radionuclidic quality control showed that the EPC is very

  5. Synovectomy of the knee with 90Y

    International Nuclear Information System (INIS)

    Spooren, P.F.M.J.; Rasker, J.J.; Arens, R.P.J.H.; Ziekenhuis Ziekenzorg, Enschede

    1985-01-01

    In 33 patients with chronic arthritis of the knee, 48 knees were treated with an intra-articular injection of 5 mCi yttrium silicate 90 Y. There were 27 patients with rheumatoid arthritis (RA) and 6 with osteoarthrosis (OA); the mean follow-up period was 33 months. At clinical investigation after 1 year, no signs of pain or swelling were found in 15 knees. In most cases, pain and swelling improved subjectively, with a mean duration of 11 months; in 20 knees, the improvement lasted more than 22 months. When radiographs showed severse destruction, 90 Y treatment was unsuccessful, but an important new finding was that most patients with mild or moderate radiological abormalities appeared to have a long-lasting improvement. The result did not correlate with erythrocyte sedimentation rate (ESR), haemoglobin or Rose titre at the time of injection or at follow up, suggesting that the result of the treatment is more dependent on local factors than on the disease activity. The results of 90 Y treatment in 6 OA knees with persistent swelling were promising regarding swelling, even in patients with moderate radiological abnormalities. The main side-effect was a sometimes painful swelling of the knee, which was always successfully treated with an intra-articular corticosteroid injection. In 90 Y-treated knees, the incidence of unstable joints was not significantly higher than in non-treated knees. In conclusion, 90 Y synovectomy may be a succesful treatment for patients older than 50 years with chronic arthritis of the knee due to RA and probably also OA, even when moderate radiological abnormalities are present. (orig.)

  6. Treatment of pains from bone metastases with 90Y

    International Nuclear Information System (INIS)

    Kutzner, J.; Daehnert, W.; Schreyer, T.; Grimm, W.; Brod, K.H.; Becker, M.

    1981-01-01

    For palliation of pain caused by bone metastases beta radiation isotope therapy was successful. As shown in experimental work on animals bone uptake of 90 Y with its shorter half-life is high when it is administered as a citrate complex. 90 Y can be eluted with high purity from a 90 Sr cow. The retention in man was found by whole-body counting to be higher than 80%. In preliminary trials on 16 patients the analgetic effect was the same as that of 89 Sr. The properties of 90 Y therapy are discussed. (orig.) [de

  7. Cohort study of somatostatin-based radiopeptide therapy with [(90)Y-DOTA]-TOC versus [(90)Y-DOTA]-TOC plus [(177)Lu-DOTA]-TOC in neuroendocrine cancers.

    Science.gov (United States)

    Villard, Linda; Romer, Anna; Marincek, Nicolas; Brunner, Philippe; Koller, Michael T; Schindler, Christian; Ng, Quinn K T; Mäcke, Helmut R; Müller-Brand, Jan; Rochlitz, Christoph; Briel, Matthias; Walter, Martin A

    2012-04-01

    Radiopeptide therapy is commonly performed with a single radioisotope. We aimed to compare the effectiveness of somatostatin-based radiopeptide therapy with a single versus a combination of radioisotopes. In a cohort study, patients with metastasized neuroendocrine cancer were treated with repeated cycles of (90)yttrium-labeled tetraazacyclododecane-tetraacetic acid modified Tyr-octreotide ([(90)Y-DOTA]-TOC) or with cycles alternating between [(90)Y-DOTA]-TOC and (177)lutetium-labeled DOTA-TOC ([(177)Lu-DOTA]-TOC) until tumor progression or permanent toxicity. Multivariable Cox regression and competing risk regression were used to study predictors of survival and renal toxicity in patients completing three or more treatment cycles. A total of 486 patients completed three or more treatment cycles; 237 patients received [(90)Y-DOTA]-TOC and 249 patients received [(90)Y-DOTA]-TOC + [(177)Lu-DOTA]-TOC. Patients receiving [(90)Y-DOTA]-TOC + [(177)Lu-DOTA]-TOC had a significantly longer survival than patients receiving [(90)Y-DOTA]-TOC alone (5.51 v 3.96 years; hazard ratio, 0.64; 95% CI, 0.47 to 0.88; P = .006). The rates of severe hematologic toxicities (6.3% v 4.4%; P = .25) and severe renal toxicity (8.9% v 11.2%; P = .47) were comparable in both groups. [(90)Y-DOTA]-TOC + [(177)Lu-DOTA]-TOC was associated with improved overall survival compared with [(90)Y-DOTA]-TOC alone in patients completing three or more cycles of treatment. Contrary to the current practice in radiopeptide therapy, our results suggest an advantage of using a combination of radioisotopes.

  8. [Preparation of citrulline microspheres by spray drying technique for colonic targeting].

    Science.gov (United States)

    Bahri, S; Zerrouk, N; Lassoued, M-A; Tsapis, N; Chaumeil, J-C; Sfar, S

    2014-03-01

    Citrulline is an amino acid that becomes essential in situations of intestinal insufficiency such as short bowel syndrome. It is therefore interesting to provide the patients with dosage forms for routing citrulline to the colon. The aim of this work is to formulate microspheres of citrulline for colonic targeting by the technique of spray drying. Eudragit(®) FS 30D was selected as polymer to encapsulate citrulline using the spray drying technique. Citrulline and Eudragit(®) FS 30D were dissolved in water and ethanol, respectively. The aqueous and the ethanolic solutions were then mixed in 1:2 (v/v) ratio. Microspheres were obtained by nebulizing the citrulline-Eudragit(®) FS 30D solution using a Mini spray dryer equipped with a 0.7mm nozzle. The microspheres have been formulated using citrulline and Eudragit(®) FS 30D. The size distribution of microspheres was determined by light diffraction. The morphology of the microspheres was studied by electron microscopy. Manufacturing yields, encapsulation rate and dissolution profiles were also studied. The microspheres obtained had a spherical shape with a smooth surface and a homogeneous size except for the microspheres containing the highest concentration of polymer (90 %). The formulation showed that the size and morphology of the microspheres are influenced by the polymer concentration. Manufacturing yields were about 51 % but encapsulation rate were always very high (above 90 %). The in vitro dissolution study showed that the use of the Eudragit(®) FS 30D under these conditions is not appropriate to change the dissolution profile of the citrulline. This technique has led to the formulation of microspheres with good physical properties in terms of morphology and size. The compression of the microspheres should help to control citrulline release for colonic targeting. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  9. The behaviour of selected yttrium containing bioactive glass microspheres in simulated body environments.

    Science.gov (United States)

    Cacaina, D; Ylänen, H; Simon, S; Hupa, M

    2008-03-01

    The study aims at the manufacture and investigation of biodegradable glass microspheres incorporated with yttrium potentially useful for radionuclide therapy of cancer. The glass microspheres in the SiO2-Na2O-P2O5-CaO-K2O-MgO system containing yttrium were prepared by conventional melting and flame spheroidization. The behaviour of the yttrium silicate glass microspheres was investigated under in vitro conditions using simulated body fluid (SBF) and Tris buffer solution (TBS), for different periods of time, according to half-life time of the Y-90. The local structure of the glasses and the effect of yttrium on the biodegradability process were evaluated by Fourier Transform Infrared (FT-IR) spectroscopy and Back Scattered Electron Imaging of Scanning Electron Microscopy (BEI-SEM) equipped with Energy Dispersive X-ray (EDX) analysis. UV-VIS spectrometry and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) was used for analyzing the release behaviour of silica and yttrium in the two used solutions. The results indicate that the addition of yttrium to a bioactive glass increases its structural stability which therefore, induced a different behaviour of the glasses in simulated body environments.

  10. Microstructure and magnetic properties of yttrium alumina silicate glass microspheres containing iron oxide

    International Nuclear Information System (INIS)

    Sharma, K.; Basak, C.B.; Prajapat, C.L.; Singh, M.R.

    2015-01-01

    Yttrium alumino-silicate glass microspheres have been used for localized delivery of high radiation dose to tissues in the treatment of hepatocellular carcinoma (BCC) and synovitis. 90 Y is a pure beta emitter with beta emission energy of 0.9367 MeV, average penetration range in tissue 2.5 mm, physical half-life of 64.2 h, thus an effective radioisotope for delivering high radiation dose to the tumor. The efficacy of radiotherapy can further be improved if the glass microspheres are doped with magnetic particles for targeted delivery of high radiation dose. Magnetic glass microspheres can also be utilized for cancer treatment using the magnetic heating of tumor cell. The magnetic glass microspheres are obtained from the glasses with nominal composition (64-x) SiO 2 -17Y 2 O 3 -19 Al 2 O 3 -xFe 2 O 3 (x=4-16 mol %). Density of glasses increases from 3.5g/cc to 3.8g/cc as iron oxide content is increased from 4 to 16 mol %. The glass transition temperature and peak crystallization temperature decreases as the iron oxide content increases. T g values of glass samples decreases with increase of Fe 2 O 3 , while SiO 2 content is decreased. SiO 2 is a network forming oxide and a decrease in the network former in glass lead to decrease in thermo-physical properties like T g . The development of ferrimagnetic crystallites in glasses arise from the conversion of iron oxide into magnetite, magnemite and hematite, which is influenced by the structural and ordering of magnetic particles. The microstructure of glass-ceramic exhibited the formation of 50-100 nm size particles. The magnetite and hematite are formed as major crystalline phases. The magnetization values increased with an increase of iron oxide content and attributed to formation of magnetite phase. Results have shown that the glass microspheres with magnetic properties can be used as potential materials for cancer treatment. (author)

  11. Adsorption of 90Sr and 90Y by bottom-set beds in the Atlantic ocean

    International Nuclear Information System (INIS)

    Gromov, V.V.; Shakhova, N.F.; Emel'yanov, E.M.

    1978-01-01

    The behaviour of 90 Sr and 90 Y has been studied in an adsorption system of sea water-bottom-set beds of the Atlantic ocean (red clay; pelitic silt). It has been shown that strontium is present in the sea water in one form, viz, Sr 2+ . Adsorption of 90 Sr with bottom-set beds follows the ion-exchange mechanism. Yttrium is present in the sea water at least three forms (two absorbable and one non-absorbable). Yttrium-90 adsorption is an irreversible process and only about 10% 90 Y is desorbed by the sea water from red clay and silt

  12. Computed tomography hepatic arteriography has a hepatic falciform artery detection rate that is much higher than that of digital subtraction angiography and 99mTc-MAA SPECT/CT: Implications for planning 90Y radioembolization?

    Energy Technology Data Exchange (ETDEWEB)

    Burgmans, M.C., E-mail: mburgmans@hotmail.com [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Too, C.W., E-mail: too.chow.wei@singhealth.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Kao, Y.H., E-mail: yung.h.kao@gmail.com [Department of Nuclear Medicine and PET, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Goh, A.S.W., E-mail: anthony.goh.s.w@sgh.com.sg [Department of Nuclear Medicine and PET, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Chow, P.K.H., E-mail: gsupc@singnet.com.sg [Department of General Surgery, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Office of Clinical Sciences, Duke-NUS Graduate Medical School Singapore, 8 College Road, Singapore 169857 (Singapore); Department of Surgical Oncology, National Cancer Center Singapore, 11 Hospital Drive, Singapore 169610 (Singapore); Tan, B.S., E-mail: tan.bien.soo@sgh.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Tay, K.H., E-mail: tay.kiang.hiong@sgh.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Lo, R.H.G., E-mail: richard.lo.h.g@sgh.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore)

    2012-12-15

    Purpose: To compare the hepatic falciform artery (HFA) detection rates of digital subtraction angiography (DSA), computed tomography hepatic arteriography (CTHA) and 99mTc-macroaggregated albumin (99mTc-MAA) single photon emission computed tomography with integrated CT (SPECT/CT) and to correlate HFA patency with complication rates of yttrium-90 (90Y) radioembolization. Material and methods: From August 2008 to November 2010, 79 patients (range 23–83 years, mean 62.3 years; 67 male) underwent pre-treatment DSA, CTHA and 99mTc-MAA scintigraphy (planar/SPECT/CT) to assess suitability for radioembolization with 90Y resin microspheres. Thirty-seven patients were excluded from the study, because CTHA was performed with a catheter position that did not result in opacification of the liver parenchyma adjacent to the falciform ligament. DSA, CTHA and 99mTc-MAA SPECT/CT images and medical records were retrospectively reviewed. Results: A patent HFA was detected in 22 of 42 patients (52.3%). The HFA detection rates of DSA, CTHA and 99mTc-MAA SPECT/CT were 11.9%, 52.3% and 13.3%, respectively (p < 0.0001). An origin from the segment 4 artery was seen in 51.7% of HFAs. Prophylactic HFA coil-embolization prior to 90Y microspheres infusion was performed in 2 patients. Of the patients who underwent radioembolization with a patent HFA, none developed supra-umbilical radiation dermatitis. One patient experienced epigastric pain attributed to post-embolization syndrome and was managed conservatively. Conclusion: The HFA detection rate of CTHA is superior to that of DSA and 99mTc-MAA SPECT/CT. Complications related to non-target radiation of the HFA vascular territory rarely occur, even in patients undergoing radioembolization with a patent HFA.

  13. Computed tomography hepatic arteriography has a hepatic falciform artery detection rate that is much higher than that of digital subtraction angiography and 99mTc-MAA SPECT/CT: Implications for planning 90Y radioembolization?

    International Nuclear Information System (INIS)

    Burgmans, M.C.; Too, C.W.; Kao, Y.H.; Goh, A.S.W.; Chow, P.K.H.; Tan, B.S.; Tay, K.H.; Lo, R.H.G.

    2012-01-01

    Purpose: To compare the hepatic falciform artery (HFA) detection rates of digital subtraction angiography (DSA), computed tomography hepatic arteriography (CTHA) and 99mTc-macroaggregated albumin (99mTc-MAA) single photon emission computed tomography with integrated CT (SPECT/CT) and to correlate HFA patency with complication rates of yttrium-90 (90Y) radioembolization. Material and methods: From August 2008 to November 2010, 79 patients (range 23–83 years, mean 62.3 years; 67 male) underwent pre-treatment DSA, CTHA and 99mTc-MAA scintigraphy (planar/SPECT/CT) to assess suitability for radioembolization with 90Y resin microspheres. Thirty-seven patients were excluded from the study, because CTHA was performed with a catheter position that did not result in opacification of the liver parenchyma adjacent to the falciform ligament. DSA, CTHA and 99mTc-MAA SPECT/CT images and medical records were retrospectively reviewed. Results: A patent HFA was detected in 22 of 42 patients (52.3%). The HFA detection rates of DSA, CTHA and 99mTc-MAA SPECT/CT were 11.9%, 52.3% and 13.3%, respectively (p < 0.0001). An origin from the segment 4 artery was seen in 51.7% of HFAs. Prophylactic HFA coil-embolization prior to 90Y microspheres infusion was performed in 2 patients. Of the patients who underwent radioembolization with a patent HFA, none developed supra-umbilical radiation dermatitis. One patient experienced epigastric pain attributed to post-embolization syndrome and was managed conservatively. Conclusion: The HFA detection rate of CTHA is superior to that of DSA and 99mTc-MAA SPECT/CT. Complications related to non-target radiation of the HFA vascular territory rarely occur, even in patients undergoing radioembolization with a patent HFA.

  14. Radioisotope generators for nuclear medicine based on Fajans adsorption on glass microspheres

    International Nuclear Information System (INIS)

    Ehrhardt, G.J.; Symes, S.; Guimon, R.K.; Zinn, K.R.

    1992-01-01

    Several radioisotope generator systems exist in which the carrier-free daughter product would precipitate if present in macro amounts at pH levels at which the parent is soluble. Included among these are the 68 Ge/ 68 Ga, 90 Sr/ 90 Y, and 47 Ca/ 47 Sc pairs. This paper reveals that in these systems, chemical separation can be achieved by Fajans adsorption of the radiocolloidal daughter products onto surfaces such as activated glass microspheres at an appropriate pH. This is followed by washing to remove the parent solution and desorption of the daughter crop by acid washes. Investigation of the Ge/Ga and Sr/Y systems demonstrated that this solid-phase extraction method is erratic, but can give daughter yields as high at 89% with separation factors up to ∼ 10,000 form parent isotope. This method has the potential for producing daughter isotopes with a minimum of metal and organic impurities for labeling cells, receptor binding ligands, and antibodies for diagnostic and radiotherapeutic purposes

  15. 90Y microsphere (TheraSphere) treatment for unresectable colorectal cancer metastases of the liver: response to treatment at targeted doses of 135-150 Gy as measured by [18F]fluorodeoxyglucose positron emission tomography and computed tomographic imaging.

    Science.gov (United States)

    Lewandowski, Robert J; Thurston, Kenneth G; Goin, James E; Wong, Ching-Yee O; Gates, Vanessa L; Van Buskirk, Mark; Geschwind, Jean-Francois H; Salem, Riad

    2005-12-01

    The purpose of this phase II study was to determine the safety and efficacy of TheraSphere treatment (90Y microspheres) in patients with liver-dominant colorectal metastases in whom standard therapies had failed or were judged to be inappropriate. Twenty-seven patients with unresectable hepatic colorectal metastases were treated at a targeted absorbed dose of 135-150 Gy. Safety and toxicity were assessed according to the National Cancer Institute's Common Toxicity Criteria, version 3.0. Response was assessed with use of computed tomography (CT) and was correlated with response on [18F]fluorodeoxyglucose (FDG) positron emission tomography (PET). Survival from first treatment was estimated with use of the Kaplan-Meier method. Tumor response measured by FDG PET imaging exceeded that measured by CT imaging for the first (88% vs 35%) and second (73% vs 36%) treated lobes. Tumor replacement of 25% or less (vs >25%) was associated with a statistically significant increase in median survival (339 days vs 162 days; P = .002). Treatment-related toxicities included mild fatigue (n = 13; 48%), nausea (n = 4; 15%), and vague abdominal pain (n = 5; 19%). There was one case of radiation-induced gastritis from inadvertent deposition of microspheres to the gastrointestinal tract (n = 1; 4%). Three patients (11%) experienced ascites/pleural effusion after treatment with TheraSphere as a consequence of liver failure in advanced-stage metastatic disease. With the exception of these three patients whose sequelae were not considered to be related to treatment, all observed toxicities were transient and resolved without medical intervention. TheraSphere administration appears to provide stabilization of liver disease with minimal toxicity in patients in whom standard systemic chemotherapy regimens have failed.

  16. Radioembolization and the dynamic role of 90Y PET/CT

    Directory of Open Access Journals (Sweden)

    Alexander S Pasciak

    2014-02-01

    Full Text Available Before the advent of tomographic imaging, it was postulated that decay of 90Y to the 0+ excited state of 90Zr may result in emission of a positron-electron pair. While the branching ratio for pair production is small (~32x10-6, PET has been successfully used to image 90Y in numerous recent patient and phantom studies. 90Y PET imaging has been performed on a variety of PET/CT systems, with and without time-of-flight (TOF and/or resolution recovery capabilities as well as on both BGO and L(YSO based scanners. On all systems, resolution and contrast superior to bremsstrahlung SPECT has been reported. The intrinsic radioactivity present in L(YSO-based PET scanners is a potential limitation associated with accurate quantification of 90Y. However, intrinsic radioactivity has been shown to have a negligible effect at the high activity concentrations common in 90Y radioembolization. Accurate quantification is possible on a variety of PET scanner models, with or without TOF, although TOF improves accuracy at lower activity concentrations. Quantitative 90Y PET images can be transformed into 3D maps of absorbed dose based on the premise that the 90Y activity distribution does not change after infusion. This transformation has been accomplished primarily with the use of 3D dose point-kernel convolution. From a clinical standpoint, 90Y PET provides a superior post-infusion evaluation of treatment technical success owing to its improved resolution. Absorbed dose maps generated from quantitative PET data can be used to predict treatment efficacy and manage patient follow-up. For patients who receive multiple treatments, this information can also be used to provide patient-specific treatment planning for successive therapies, potentially improving response. The broad utilization of 90Y PET has the potential to provide a wealth of dose-response information, which may lead to development of improved radioembolization treatment-planning models in the future.

  17. A retrospective review of Y90 synovectomy in Auckland

    International Nuclear Information System (INIS)

    Stamp, L.

    2000-01-01

    Full text: A retrospective review of Yttrium 90 synovectomies carried out from June 1997 to February 1999 in Auckland Hospital to determine outcome from the procedure. Methods: Patients were sent a questionnaire for each treated knee The principal outcome measures assessed in the month prior and the 6 months after the Y90 were pain, swelling, walking distance and overall disability score. Referring doctors were sent a questionnaire to provide information on duration of synovitis and treatment. Outcomes measured were presence of effusion 6 months after the Y90, requirement for intra-articular steroid in the 12 months prior to and after the yttrium and change of therapy due lo ongoing symptoms in the treated knee. Results: 29 patients and 40 knees had Y90 during the study period 86% patients with 87.5% knees responded. Referring doctors for 86% patients accounting for 87.5% knees responded. The procedure was well tolerated with the majority of patients reporting nil-mild discomfort during and in the 24 hours after Y90. 86% knees treated reported improvement with a reduction in pain and swelling Patient global assessment reduced from 3.8 to 2.0 while physician global assessment reduced from 3.9 to 3.0. There was an improvement in walking distance 6 months after Y90 with the number of knees able to walk >1km increasing from 2 to 17 14 of 25 patients required a change in treatment because of ongoing problems in the treated knee and one patient has undergone knee joint replacement One further patient is waiting knee joint replacement The need for intra-articular steroid was reduced with 83%, knees having an average of 2.4 steroid injections in the 12 months prior to Y90 compared to 38% knees having an average of 0.7 steroid injections in the 12 months after Y90. Of the 30 knees reporting Improvement 24 knees are at least 12 months post Y90. Of these 50% were Improved at 12 months. As a result of this audit we continue to offer this procedure in the Auckland area, and

  18. Preparation & in vitro evaluation of 90Y-DOTA-rituximab

    Science.gov (United States)

    Kameswaran, Mythili; Pandey, Usha; Dash, Ashutosh; Samuel, Grace; Venkatesh, Meera

    2016-01-01

    Background & objectives: Radioimmunotherapy is extensively being used for the treatment of non-Hodgkin's lymphoma (NHL). Use of rituximab, a chimeric anti-CD20 antibody directed against the CD20 antigen in combination with suitable beta emitters is expected to result in good treatment response by its cross-fire and bystander effects. The present work involves the conjugation of p-isothiocyanatobenzyl DOTA (p-SCN-Bn-DOTA) to rituximab, its radiolabelling with 90Y and in vitro and in vivo evaluation to determine its potential as a radioimmunotherapeutic agent. Methods: Rituximab was conjugated with p-SCN-Bn-DOTA at 1:1 antibody: DOTA molar ratio. The number of DOTA molecules linked to one molecule of rituximab was determined by radioassay and spectroscopic assay. Radiolabelling of rituximab with 90Y was carried out and its in vitro stability was evaluated. In vitro cell binding studies were carried out in Raji cells expressing CD20 antigen. Biodistribution studies were carried out in normal Swiss mice. Results: Using both radioassay and spectroscopic method, it was determined that about five molecules of DOTA were linked to rituximab. Radiolabelling of the rituximab conjugate with 90Y and subsequent purification on PD-10 column gave a product with radiochemical purity (RCP) > 98 per cent which was retained at > 90 per cent up to 72 h when stored at 37°C. In vitro cell binding experiments of 90Y-DOTA-rituximab with Raji cells exhibited specific binding of 20.7 ± 0.1 per cent with 90Y-DOTA-rituximab which reduced to 15.5 ± 0.2 per cent when incubated with cold rituximab. The equilibrium constant Kd for 90Y-DOTA-Rituximab was determined to be 3.38 nM. Radiolabelled antibody showed clearance via hepatobiliary and renal routes and activity in tibia was found to be quite low indicating in vivo stability of 90Y-DOTA-rituximab. Interpretation & conclusions: p-SCN-Bn-DOTA was conjugated with rituximab and radiolabelling with 90Y was carried out. In vitro studies carried

  19. Preparation of nano-hydroxyapatite/poly(l-lactide) biocomposite microspheres

    International Nuclear Information System (INIS)

    Qiu Xueyu; Han Yadong; Zhuang Xiuli; Chen Xuesi; Li Yuesheng; Jing Xiabin

    2007-01-01

    Nano-hydroxyapatite (HA)/poly(l-lactide) (PLLA) composite microspheres with relatively uniform size distribution were prepared by a solid-in-oil-in-water (s/o/w) emusion solvent evaporation method. The encapsulation of the HA nanopaticles in microshperes was significantly improved by grafting PLLA on the surface of the HA nanoparticles (p-HA) during emulsion process. This procedure gave a possibility to obtain p-HA/PLLA composite microspheres with uniform morphology and the encapsulated p-HA nanoparticle loading reached up to 40 wt% (33 wt% of pure HA) in the p-HA/PLLA composite microspheres. The microstructure of composite microspheres from core-shell to single phase changed with the variation of p-HA to PLLA ratios. p-HA/PLLA composite microspheres with the diameter range of 2-3 μm were obtained. The entrapment efficiency of p-HA in microspheres could high up to 90 wt% and that of HA was only 13 wt%. Surface and bulk characterizations of the composite microspheres were performed by measurements such as wide angle X-ray diffraction (WAXD), thermal gravimetric analysis (TGA), environmental scanning electron microscope (ESEM) and transmission electron microscopy (TEM)

  20. Therapeutic result of radioactive nuclide 90Sr/90Y treatment in patients with benign prostatic hypertrophy (BPH)

    International Nuclear Information System (INIS)

    Chen Hanchao; Li Yuying

    2008-01-01

    Objective: To study the effect of radioactive nuclide 90 Sr/ 90 Y treatment in patients with benign prostatic hypertrophy (BPH). Methods: Sixty patients with BPH were treated with a course of transurethral radioactive nuclide 90 Sr/ 90 Y therapy. Results: The severity of BPH was assessed with four parameters: maximal flow rate (MFR), volume of residual urine (VRU), international prostatic symptom score (IPSS) and volume (size) of prostate. In this series, the total effective rate was 93.33% with no treatment- related mortality. Favorable changes of the parameters after a course of radioactive nuclide therapy were significant. Conclusion: Radioactive nuclide 90 Sr/ 90 Y therapy for patients with BPH was safe, easily performed and quite effective. This procedure is worth popularizing in appropriate patients. (authors)

  1. The effect of 90Sr/90Y β-rays on benign prostatic hyperplasia

    International Nuclear Information System (INIS)

    Kong Xiangbo; Ma Qingjie; Gu Xinquan

    2004-01-01

    Objective: To investigate the effect of 90Sr/90Y β-rays on Benign prostatic hyperplasia (BPH). Methods: In order to carry out β intracavitary irradiation, the active area of the applicator was located into prostate gland section of urethra in 37 patients. The dose was controlled 30∼50Gy in each patient and the patients were observed for 3 months. Results: After two weeks 26 cases were remarkably improved, 7 cases were improved and 4 cases were ineffective. There was significant difference on MFR, PVR, I-PSS and volume of prostate gland before and after treatment (P<0.01=. Conclusion: Clinical tests indicate that the 90Sr/90Y prostatic hyperplasia applicators provide a safe, effective ,non-invasive and economical therapeutic method for BPH. It is especially applicable for old and high-risk patients. (authors)

  2. Half-life evaluations for 3H, 90Sr, and 90Y

    International Nuclear Information System (INIS)

    MacMahon, Desmond

    2006-01-01

    A recent paper has reviewed methods for the evaluation of discrepant sets of data and demonstrated the results of applying these methods to the published half-life data of 90 Sr and 137 Cs [MacMahon, T.D., Pearce, A., Harris, P., 2004. Convergence of techniques for the evaluation of discrepant data. Appl. Radiat. Isot. 60, 275-281]. The half-life data for 3 H has been subject to a comprehensive review and critical evaluation by Lucas and Unterweger [2000. Comprehensive review and critical evaluation of the half-life of tritium. J. Res. Natl. Inst. Stand. Technol. 105, 541-549]. The current paper reports the results of applying the various evaluation procedures of MacMahon et al. Convergence of techniques for the evaluation of discrepant data. Appl. Radiat. Isot. 60, 275-281] to the data of Lucas and Unterweger [Comprehensive review and critical evaluation of the half-life of tritium. J. Res. Natl. Inst. Stand. Technol. 105, 541-549], resulting in a recommended half-life of 4497(4) days. MacMahon et al. [Convergence of techniques for the evaluation of discrepant data. Appl. Radiat. Isot. 60, 275-281] highlighted problems in the evaluation of the discrepant half-life data of 90 Sr, in particular the worrying upward trend in the data, where the weighted mean of all the measurements increases, on average, by 35 days each time a new measurement result is added. The current paper reports on further analyses of these data. New measurements of the half-life of 90 Y have been reported by Kossert and Schrader [2004. Standardization by liquid scintillation counting and half-life measurements of 90 Y. Appl. Radiat. Isot. 60, 741]. This has prompted a new evaluation of all available published 90 Y half-life data. The data are fairly consistent, and a value of 64.063(16) h is recommended

  3. Determination of 90Sr in milk by solvent extraction of 90Y

    International Nuclear Information System (INIS)

    Mitsuhashi, Toshihiko; Sakanoue, Masanobu.

    1977-01-01

    In order to replace the conventional method using violent fuming nitric acid, a new method for the determination of 90 Sr in milk has been developed by using the solvent extraction with bis (2-ethylhexyl) phosphoric acid (HDEHP). The daughter nuclide 90 Y in a radiochemical equilibrium with its parent 90 Sr was extracted with 2:1 HDEHP-toluene from the acid solution (1M HCl) of milk ash sample prepared by dry-ashing. After stripping with 8M HCl, 90 Y, together with stable yttrium added as carrier, was precipitated as oxalate to prepare β-counting source. The radiochemical purity was confirmed by decay curve. The decontamination of strontium was checked by applying non-dispersive fluorescence x-ray analysis using 133 Ba as irradiating source. Bone samples of cow were also analyzed by the same method and the results were compared with those obtained by other methods. The duplicate crosschecking analyses of finely ground bone samples were carried out to examine the effectiveness of this method. This simple new method was found to be very effective for the routine analysis of 90 Sr in these samples. (auth.)

  4. Validation of Extraction Paper Chromatography as a Quality Control Technique for Analysis of Sr-90 in Y-90 Product

    International Nuclear Information System (INIS)

    Nipavan, Poramatikul; Jatupol, Sangsuriyan; Wiranee, Sriweing

    2009-07-01

    Full text: Yttrium-90 (Y-90) is a daughter product of strontium-90 (Sr-90). It is specified that there should be less than 2 micro-curie of Sr-90 in Y-90 radiopharmaceuticals. Since both nuclides are beta emitting and there is always a contamination of Y-90 in Sr-90 sample, validation of the analytical method is necessary. In this study, commercial Y-90 and Sr-85 (a gamma emitting isotope of strontium) were used as daughter and mother nuclides, respectively. Extraction paper chromatography technique and its efficient validation method were investigated. Bis-(2-ethylhexyl) diphosphonate was dropped at the origin of chromatography paper and air dried prior to sample drops. Validation of the separation was done by radio-chromatography scanning of the chromatography paper. Their energy spectra were identified in the spectra mode of Packard Cobra II automatic gamma counter, which can differentiate a pure gamma, a pure beta and a mixture of beta and gamma nuclides. Results showed that yttrium acetate remained fixed at the origin of the chromatography paper while strontium acetate moved to the solvent front when developed in saline. In conclusion, the extraction paper chromatography technique can effectively separate Sr-90 from Y-90

  5. The origin and reduction of spurious extrahepatic counts observed in 90Y non-TOF PET imaging post radioembolization

    Science.gov (United States)

    Walrand, Stephan; Hesse, Michel; Jamar, François; Lhommel, Renaud

    2018-04-01

    Our literature survey revealed a physical effect unknown to the nuclear medicine community, i.e. internal bremsstrahlung emission, and also the existence of long energy resolution tails in crystal scintillation. None of these effects has ever been modelled in PET Monte Carlo (MC) simulations. This study investigates whether these two effects could be at the origin of two unexplained observations in 90Y imaging by PET: the increasing tails in the radial profile of true coincidences, and the presence of spurious extrahepatic counts post radioembolization in non-TOF PET and their absence in TOF PET. These spurious extrahepatic counts hamper the microsphere delivery check in liver radioembolization. An acquisition of a 32P vial was performed on a GSO PET system. This is the ideal setup to study the impact of bremsstrahlung x-rays on the true coincidence rate when no positron emission and no crystal radioactivity are present. A MC simulation of the acquisition was performed using Gate-Geant4. MC simulations of non-TOF PET and TOF-PET imaging of a synthetic 90Y human liver radioembolization phantom were also performed. Internal bremsstrahlung and long energy resolution tails inclusion in MC simulations quantitatively predict the increasing tails in the radial profile. In addition, internal bremsstrahlung explains the discrepancy previously observed in bremsstrahlung SPECT between the measure of the 90Y bremsstrahlung spectrum and its simulation with Gate-Geant4. However the spurious extrahepatic counts in non-TOF PET mainly result from the failure of conventional random correction methods in such low count rate studies and poor robustness versus emission-transmission inconsistency. A novel proposed random correction method succeeds in cleaning the spurious extrahepatic counts in non-TOF PET. Two physical effects not considered up to now in nuclear medicine were identified to be at the origin of the unusual 90Y true coincidences radial profile. TOF reconstruction removing

  6. Development of a dosimetric system for 90Sr + 90Y betatherapy applicators

    International Nuclear Information System (INIS)

    Coelho, Talita Salles

    2010-01-01

    The 90 Sr+ 90 Y applicators, used in betatherapy for prevention of keloids and pterigium, are imported and many times their dosimetric features are shown only in an illustrated form by the manufacturers. The exhaustive routine of the medical physicists in the clinic do not make possible the accomplishment of procedures for the confirmation of these parameters. This work presents the development of a methodology for the dosimetry of 90 Sr+ 90 Y betatherapy applicators. The Monte Carlo code MCNP5 was used for the simulation of the percentage depth dose curves and dose distribution profiles produced by these applicators. The experimental measurements of the radial and axial radiation attenuation, have been done with a mini-extrapolation chamber, thermoluminescent dosimeters and radiographic films. The experimental results have been compared with the simulated values. Both percentage depth dose curves and the radial dose profiles, the theoretical and the experimental ones, have presented good agreement, which may validate the use of the MCNP5 for these simulations, confirming the viability of the usage of this method in procedures of beta emitter sources dosimetry. (author)

  7. (90)Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction.

    Science.gov (United States)

    Carlier, Thomas; Willowson, Kathy P; Fourkal, Eugene; Bailey, Dale L; Doss, Mohan; Conti, Maurizio

    2015-07-01

    (90)Y -positron emission tomography (PET) imaging is becoming a recognized modality for postinfusion quantitative assessment following radioembolization therapy. However, the extremely low counts and high random fraction associated with (90)Y -PET may significantly impair both qualitative and quantitative results. The aim of this work was to study image quality and noise level in relation to the quantification and bias performance of two types of Siemens PET scanners when imaging (90)Y and to compare experimental results with clinical data from two types of commercially available (90)Y microspheres. Data were acquired on both Siemens Biograph TruePoint [non-time-of-flight (TOF)] and Biograph microcomputed tomography (mCT) (TOF) PET/CT scanners. The study was conducted in three phases. The first aimed to assess quantification and bias for different reconstruction methods according to random fraction and number of true counts in the scan. The NEMA 1994 PET phantom was filled with water with one cylindrical insert left empty (air) and the other filled with a solution of (90)Y . The phantom was scanned for 60 min in the PET/CT scanner every one or two days. The second phase used the NEMA 2001 PET phantom to derive noise and image quality metrics. The spheres and the background were filled with a (90)Y solution in an 8:1 contrast ratio and four 30 min acquisitions were performed over a one week period. Finally, 32 patient data (8 treated with Therasphere(®) and 24 with SIR-Spheres(®)) were retrospectively reconstructed and activity in the whole field of view and the liver was compared to theoretical injected activity. The contribution of both bremsstrahlung and LSO trues was found to be negligible, allowing data to be decay corrected to obtain correct quantification. In general, the recovered activity for all reconstruction methods was stable over the range studied, with a small bias appearing at extremely high random fraction and low counts for iterative algorithms

  8. 90Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction

    International Nuclear Information System (INIS)

    Carlier, Thomas; Willowson, Kathy P.; Fourkal, Eugene; Bailey, Dale L.; Doss, Mohan; Conti, Maurizio

    2015-01-01

    Purpose: 90 Y -positron emission tomography (PET) imaging is becoming a recognized modality for postinfusion quantitative assessment following radioembolization therapy. However, the extremely low counts and high random fraction associated with 90 Y -PET may significantly impair both qualitative and quantitative results. The aim of this work was to study image quality and noise level in relation to the quantification and bias performance of two types of Siemens PET scanners when imaging 90 Y and to compare experimental results with clinical data from two types of commercially available 90 Y microspheres. Methods: Data were acquired on both Siemens Biograph TruePoint [non-time-of-flight (TOF)] and Biograph microcomputed tomography (mCT) (TOF) PET/CT scanners. The study was conducted in three phases. The first aimed to assess quantification and bias for different reconstruction methods according to random fraction and number of true counts in the scan. The NEMA 1994 PET phantom was filled with water with one cylindrical insert left empty (air) and the other filled with a solution of 90 Y . The phantom was scanned for 60 min in the PET/CT scanner every one or two days. The second phase used the NEMA 2001 PET phantom to derive noise and image quality metrics. The spheres and the background were filled with a 90 Y solution in an 8:1 contrast ratio and four 30 min acquisitions were performed over a one week period. Finally, 32 patient data (8 treated with Therasphere ® and 24 with SIR-Spheres ® ) were retrospectively reconstructed and activity in the whole field of view and the liver was compared to theoretical injected activity. Results: The contribution of both bremsstrahlung and LSO trues was found to be negligible, allowing data to be decay corrected to obtain correct quantification. In general, the recovered activity for all reconstruction methods was stable over the range studied, with a small bias appearing at extremely high random fraction and low counts for

  9. Preparation and drug controlled release of porous octyl-dextran microspheres.

    Science.gov (United States)

    Hou, Xin; Liu, Yanfei

    2015-01-01

    In this work, porous octyl-dextran microspheres with excellent properties were prepared by two steps. Firstly, dextran microspheres were synthesized by reversed-phase suspension polymerization. Secondly, octyl-dextran microspheres were prepared by the reaction between dextran microspheres and ethylhexyl glycidyl ether and freezing-drying method. Porous structure of microspheres was formed through the interaction between octyl groups and organic solvents. The structure, morphology, dry density, porosity and equilibrium water content of porous octyl-dextran microspheres were systematically investigated. The octyl content affected the properties of microspheres. The results showed that the dry density of microspheres decreased from 2.35 to 1.21 g/ml, porosity increased from 80.68 to 95.05% with the octyl content increasing from 0.49 to 2.28 mmol/g. Meanwhile, the equilibrium water content presented a peak value (90.18%) when the octyl content was 2.25 mmol/g. Octyl-dextran microspheres showed high capacity. Naturally drug carriers play an important role in drug-delivery systems for their biodegradability, wide raw materials sources and nontoxicity. Doxorubicin (DOX) was used as a drug model to examine the drug-loading capacity of porous octyl-dextran microspheres. The drug-loading efficiency increased with the increase in microspheres/drug ratio, while the encapsulation efficiency decreased. When microspheres/drug mass ratio was 4/1, the drug-loading efficiency and encapsulation efficiency were 10.20 and 51.00%, respectively. The release rate of DOX increased as drug content and porosity increased. In conclusion, porous octyl-dextran microspheres were synthesized successfully and have the potential to serve as an effective delivery system in drug controlled release.

  10. Carefully calibrated microsphere embolization of tumors and AVMs

    International Nuclear Information System (INIS)

    Laurent, A.; Wassef, M.; Beaujeux, R.; Hodes, J.E.; Gobin, P.Y.; Schenker, C.; Bouchez, B.; Brette, M.D.; Aymard, A.; Cophignon, J.; Merland, J.J.

    1990-01-01

    This paper evaluates the efficacy of a new type of uniformly calibrated microsphere for embolization of various pathologies. Fourteen tumors (five intracranial, eight extracranial, one spine), and seven facial arteriovenous malformations (AVMs) (nose, lip, and scalp) were embolized preoperatively. Angiographic, surgical devascularization, and histologic findings were correlated with the spheres' size. In the second part of the study, spinal cord (n = 22) and intracerbral (n = 14) AVM, Weber-Osler-Rendu disease (n = 2), and epistaxis (n = 1) embolization was angiographically evaluated

  11. Yttrium-86-labelled human serum albumin microspheres: relation of surface structure with in vivo stability

    International Nuclear Information System (INIS)

    Schiller, Eik; Bergmann, Ralf; Pietzsch, Jens; Noll, Bernhard; Sterger, Antje; Johannsen, Bernd; Wunderlich, Gerd; Pietzsch, Hans-Juergen

    2008-01-01

    Introduction: Radiolabelled particles are an attractive tool in the therapy of malignancies of the liver. We consider particles manufactured from denatured human serum albumin (HSA) as useful carriers of therapeutic radionuclides. Covalent attachment of suitable chelators onto the surface of the spheres promises an easy access to radiolabelled HSA microspheres. Methods: We synthesized 1,4,7,10-tetraazacyclododecane-N,N',N'',N'''-tetraacetic acid (DOTA) bearing smooth, medium-rough and rough surfaced HSA microspheres (mean diameter: 25 μm). In vitro stability of 86 Y-labelled particles was determined after incubation in human plasma and in a DTPA challenge experiment. In vivo stability of 86 Y DOTA-HSA microspheres was determined after single intravenous application in rats. Subsequently, the particles were completely trapped in the lung microvasculature. Thus, the lung serves in our experiments as target organ. Results: DOTA-HSA microspheres were 86 Y labelled in reproducible high yields (>95%). No differences between smooth and rough surfaced spheres were found for both DOTA coupling and 86 Y labelling. Labelled microspheres showed high in vitro stability in human plasma and in DTPA solution with only 8±1% and 2±0% loss of radioactivity from the surface, respectively, 48 h postinjection (pi). The three batches (smooth, medium-rough and rough surfaced microspheres) differed considerably in their radioactivity recovery in the lungs of rats 48 h pi. Smooth particles showed the highest in vivo stability of the radiolabel on the surface of the spheres, presumably because of slower proteolytic degradation. Conclusion: We found that for the preparation of HSA-derived microspheres for radiotherapeutic application, smooth surfaced spheres are superior to rough spheres due to their higher in vivo stability of the radionuclide fixation

  12. Carboxyl-Functionalized Polymeric Microspheres Prepared by One-Stage Photoinitiated RAFT Dispersion Polymerization

    Directory of Open Access Journals (Sweden)

    Jianbo Tan

    2017-12-01

    Full Text Available Herein, we report a photoinitiated reversible addition-fragmentation chain transfer (RAFT dispersion copolymerization of methyl methacrylate (MMA and methyl methacrylic (MAA for the preparation of highly monodisperse carboxyl-functionalized polymeric microspheres. High rates of polymerization were observed, with more than 90% particle yields being achieved within 3 h of UV irradiation. Effects of reaction parameters (e.g., MAA concentration, RAFT agent concentration, photoinitiator concentration, and solvent composition were studied in detail, and highly monodisperse polymeric microspheres were obtained in most cases. Finally, silver (Ag composite microspheres were prepared by in situ reduction of AgNO3 using the carboxyl-functionalized polymeric microspheres as the template. The obtained Ag composite microspheres were able to catalyze the reduction of methylene blue (MB with NaBH4 as a reductant.

  13. Power output and efficiency of beta-emitting microspheres

    International Nuclear Information System (INIS)

    Cheneler, David; Ward, Michael

    2015-01-01

    Current standard methods to calculate the dose of radiation emitted during medical applications by beta-minus emitting microspheres rely on an over-simplistic formalism. This formalism is a function of the average activity of the radioisotope used and the physiological dimensions of the patient only. It neglects the variation in energy of the emitted beta particle due to self-attenuation, or self-absorption, effects related to the finite size of the sphere. Here it is assumed the sphere is comprised of a pure radioisotope with beta particles being emitted isotropically throughout the material. The full initial possible kinetic energy distribution of a beta particle is taken into account as well as the energy losses due to scattering by other atoms in the microsphere and bremsstrahlung radiation. By combining Longmire’s theory of the mean forward range of charged particles and the Rayleigh distribution to take into account the statistical nature of scattering and energy straggling, the linear attenuation, or self-absorption, coefficient for beta-emitting radioisotopes has been deduced. By analogy with gamma radiation transport in spheres, this result was used to calculate the rate of energy emitted by a beta-emitting microsphere and its efficiency. Comparisons to standard point dose kernel formulations generated using Monte Carlo data show the efficacy of the proposed method. Yttrium-90 is used as a specific example throughout, as a medically significant radioisotope, frequently used in radiation therapy for treating cancer. - Highlights: • Range-energy relationship for the beta particles in yttrium-90 is calculated. • Formalism for the semi-analytical calculation of self-absorption coefficients. • Energy-dependent self-absorption coefficient calculated for yttrium-90. • Flux rate of beta particles from a self-attenuating radioactive sphere is shown. • The efficiency of beta particle emitting radioactive microspheres is calculated

  14. Aspects of radiation protection during the treatment of liver cancer using yttrium-90 labelled microspheres

    International Nuclear Information System (INIS)

    Klemp, P.F.B.; Perry, A.M.; Fox, R.A.; Gray, B.N.; Burton, M.A.

    1989-01-01

    Twenty eight patients have received treatment for liver cancer by the intra-hepatic arterial injection of between 1 and 4 GBq of yttrium-90 labelled microspheres. The injection was performed at laparotomy. If 11.1 MBq of yttrium-90 are distributed evenly over 1 sq cm of tissue, the tissue surface will suffer an initial beta dose rate of 16.2 Gy h -1 . Special precautions are therefore essential during the injection procedure, subsequently in nursing the patient and if further intervention becomes necessary. A specially designed apparatus is used for the injection, glass spectacles are worn and if the active liver is to be handled, lead rubber gloves are used. The theatre is prepared so that contaminated items can be easily isolated and a 'spill pack' is readily available. At completion of the operation, the bremsstrahlung dose rate at 15 cm from the liver is initially 15 μSv h -1 GBq -1 . Contamination of urine is typically 20 to 50 kBq L -1 while the contamination of other body fluids is negligible. Finger doses to the surgeons has varied from 2 to 5 mSv GBq -1 injected while personnel film badges used to monitor the dose equivalent to the surgeons and ward staff have recorded maximum doses of 1.5 mSv and 300 μSv respectively. 11 refs., 1 fig., 3 tabs

  15. Development of Poly Lactic/Glycolic Acid (PLGA Microspheres for Controlled Release of Rho-Associated Kinase Inhibitor

    Directory of Open Access Journals (Sweden)

    Sho Koda

    2017-01-01

    Full Text Available Purpose. The purpose of this study was to investigate the feasibility of poly lactic/glycolic acid (PLGA as a drug delivery carrier of Rho kinase (ROCK inhibitor for the treatment of corneal endothelial disease. Method. ROCK inhibitor Y-27632 and PLGA were dissolved in water with or without gelatin (W1, and a double emulsion [(W1/O/W2] was formed with dichloromethane (O and polyvinyl alcohol (W2. Drug release curve was obtained by evaluating the released Y-27632 by using high performance liquid chromatography. PLGA was injected into the anterior chamber or subconjunctiva in rabbit eyes, and ocular complication was evaluated by slitlamp microscope and histological analysis. Results. Y-27632 incorporated PLGA microspheres with different molecular weights, and different composition ratios of lactic acid and glycolic acid were fabricated. A high molecular weight and low content of glycolic acid produced a slower and longer release. The Y-27632 released from PLGA microspheres significantly promoted the cell proliferation of cultured corneal endothelial cells. The injection of PLGA did not induce any evident eye complication. Conclusions. ROCK inhibitor-incorporated PLGA microspheres were fabricated, and the microspheres achieved the sustained release of ROCK inhibitor over 7–10 days in vitro. Our data should encourage researchers to use PLGA microspheres for treating corneal endothelial diseases.

  16. Evaluation of quantitative planar 90Y bremsstrahlung whole-body imaging

    International Nuclear Information System (INIS)

    Minarik, D; Ljungberg, M; Gleisner, K Sjoegreen; Segars, P

    2009-01-01

    With high-dose administration of 90 Y labeled antibodies, it is possible to image 90 Y without an admixture of 111 In. We have earlier shown that it is possible to perform quantitative 90 Y bremsstrahlung SPECT for dosimetry purposes with reasonable accuracy. However, whole-body (WB) activity quantification with the conjugate view method is not as time consuming as SPECT and has been the method of choice for dosimetry. We have investigated the possibility of using a conjugate view method where scatter-, backscatter- and septal-penetration compensations are performed by inverse filtering and attenuation correction is performed with a WB x-ray image, for total-body and organ activity quantification of 90 Y. The method was evaluated using both Monte Carlo simulated scintillation camera images using realistic source distributions, and by an experimental phantom study. The method was evaluated in terms of image quality and accuracy of the activity quantification. The experimental phantom study was performed using the RSD torso phantom with 90 Y activity uniformly distributed in the liver insert. A GE Discovery VH/Hawkeye system was used to acquire the image. The simulation study was performed for a realistic activity distribution in the NCAT anthropomorphic phantom where 90 Y bremsstrahlung images were generated using the SIMIND MC program. Two different phantom configurations and two activity distributions were simulated. To mimic the RSD phantom experiment one simulation study was also made with 90 Y activity located only in the liver. The SIMIND program was configured to resemble a GE Discovery VH/Hawkeye system. An x-ray projector program was used to generate whole-body x-ray images from the NCAT phantom for attenuation correction in the conjugate view method. Organ activities were calculated from ROIs that exactly covered the organs. Corrections for background activity, overlapping activity and source extension in the depth direction were applied on the ROI data

  17. Microradiographic microsphere manipulator

    International Nuclear Information System (INIS)

    Singleton, R.M.

    1980-01-01

    A method and apparatus are provided for radiographic characterization of small hollow spherical members (microspheres), constructed of either optically transparent or opaque materials. The apparatus involves a microsphere manipulator which holds a batch of microspheres between two parallel thin plastic films for contact microradiographic characterization or projection microradiography thereof. One plastic film is translated to relative to and parallel to the other to roll the microspheres through any desired angle to allow different views of the microspheres

  18. A PET reconstruction formulation that enforces non-negativity in projection space for bias reduction in Y-90 imaging

    Science.gov (United States)

    Lim, Hongki; Dewaraja, Yuni K.; Fessler, Jeffrey A.

    2018-02-01

    Most existing PET image reconstruction methods impose a nonnegativity constraint in the image domain that is natural physically, but can lead to biased reconstructions. This bias is particularly problematic for Y-90 PET because of the low probability positron production and high random coincidence fraction. This paper investigates a new PET reconstruction formulation that enforces nonnegativity of the projections instead of the voxel values. This formulation allows some negative voxel values, thereby potentially reducing bias. Unlike the previously reported NEG-ML approach that modifies the Poisson log-likelihood to allow negative values, the new formulation retains the classical Poisson statistical model. To relax the non-negativity constraint embedded in the standard methods for PET reconstruction, we used an alternating direction method of multipliers (ADMM). Because choice of ADMM parameters can greatly influence convergence rate, we applied an automatic parameter selection method to improve the convergence speed. We investigated the methods using lung to liver slices of XCAT phantom. We simulated low true coincidence count-rates with high random fractions corresponding to the typical values from patient imaging in Y-90 microsphere radioembolization. We compared our new methods with standard reconstruction algorithms and NEG-ML and a regularized version thereof. Both our new method and NEG-ML allow more accurate quantification in all volumes of interest while yielding lower noise than the standard method. The performance of NEG-ML can degrade when its user-defined parameter is tuned poorly, while the proposed algorithm is robust to any count level without requiring parameter tuning.

  19. Determination of /sup 90/Sr in milk by solvent extraction of /sup 90/Y

    Energy Technology Data Exchange (ETDEWEB)

    Mitsuhashi, T [National Inst. of Animal Industry, Chiba (Japan); Sakanoue, M

    1977-10-01

    In order to replace the conventional method using violent fuming nitric acid, a new method for the determination of /sup 90/Sr in milk has been developed by using the solvent extraction with bis (2-ethylhexyl) phosphoric acid (HDEHP). The daughter nuclide /sup 90/Y in a radiochemical equilibrium with its parent /sup 90/Sr was extracted with 2:1 HDEHP-toluene from the acid solution (1M HCl) of milk ash sample prepared by dry-ashing. After stripping with 8M HCl, /sup 90/Y, together with stable yttrium added as carrier, was precipitated as oxalate to prepare ..beta..-counting source. The radiochemical purity was confirmed by decay curve. The decontamination of strontium was checked by applying non-dispersive fluorescence x-ray analysis using /sup 133/Ba as irradiating source. Bone samples of cow were also analyzed by the same method and the results were compared with those obtained by other methods. The duplicate crosschecking analyses of finely ground bone samples were carried out to examine the effectiveness of this method. This simple new method was found to be very effective for the routine analysis of /sup 90/Sr in these samples.

  20. Development of a dosimetric system for {sup 90}Sr + {sup 90}Y betatherapy applicators; Desenvolvimento de um sistema de dosimetria para aplicadores de betaterapia de {sup 90}Sr + {sup 90}Y

    Energy Technology Data Exchange (ETDEWEB)

    Coelho, Talita Salles

    2010-07-01

    The {sup 90}Sr+{sup 90}Y applicators, used in betatherapy for prevention of keloids and pterigium, are imported and many times their dosimetric features are shown only in an illustrated form by the manufacturers. The exhaustive routine of the medical physicists in the clinic do not make possible the accomplishment of procedures for the confirmation of these parameters. This work presents the development of a methodology for the dosimetry of {sup 90}Sr+{sup 90}Y betatherapy applicators. The Monte Carlo code MCNP5 was used for the simulation of the percentage depth dose curves and dose distribution profiles produced by these applicators. The experimental measurements of the radial and axial radiation attenuation, have been done with a mini-extrapolation chamber, thermoluminescent dosimeters and radiographic films. The experimental results have been compared with the simulated values. Both percentage depth dose curves and the radial dose profiles, the theoretical and the experimental ones, have presented good agreement, which may validate the use of the MCNP5 for these simulations, confirming the viability of the usage of this method in procedures of beta emitter sources dosimetry. (author)

  1. Enteric-coated epichlorohydrin crosslinked dextran microspheres for site-specific delivery to colon.

    Science.gov (United States)

    Rai, Gopal; Yadav, Awesh K; Jain, Narendra K; Agrawal, Govind P

    2015-01-01

    Enteric-coated epichlorohydrin crosslinked dextran microspheres containing 5-Fluorouracil (5-FU) for colon drug delivery was prepared by emulsification-crosslinking method. The formulation variables studied includes different molecular weights of dextran, volume of crosslinking agent, stirring speed, time and temperature. Dextran microspheres showed mean entrapment efficiencies ranging between 77 and 87% and mean particle size ranging between 10 and 25 µm. About 90% of drug was released from uncoated dextran microspheres within 8 h, suggesting the fast release and indicated the drug loaded in uncoated microspheres, released before they reached colon. Enteric coating (Eudragit-S-100 and Eudragit-L-100) of dextran microspheres was performed by oil-in-oil solvent evaporation method. The release study of 5-FU from coated dextran microspheres was complete retardation in simulated gastric fluid (pH 1.2) and once the coating layer of enteric polymer was dissolved at higher pH (7.4 and 6.8), a controlled release of the drug from the microspheres was observed. Further, the release of drug was found to be higher in the presence of dextranase and rat caecal contents, indicating the susceptibility of dextran microspheres to colonic enzymes. Organ distribution and pharmacokinetic study in albino rats was performed to establish the targeting potential of optimized formulation in the colon.

  2. A Comparative Study of Production of Glass Microspheres by using Thermal Process

    Science.gov (United States)

    Lee, May Yan; Tan, Jully; Heng, Jerry YY; Cheeseman, Christopher

    2017-06-01

    Microspheres are spherical particles that can be distinguished into two categories; solid or hollow. Microspheres typical ranges from 1 to 200 μm in diameter. Microsphere are made from glass, ceramic, carbon or plastic depending on applications. Solid glass microsphere is manufactured by direct burning of glass powders while hollow glass microspheres is produced by adding blowing agent to glass powder. This paper presented the production of glass microspheres by using the vertical thermal flame (VTF) process. Pre-treated soda lime glass powder with particle sized range from 90 to 125μm was used in this work. The results showed that glass microspheres produced by two passes through the flame have a more spherical shape as compared with the single pass. Under the Scanning Electron Microscope (SEM), it is observed that there is a morphology changed from uneven surface of glass powders to smooth spherical surface particles. Qualitative analysis for density of the pre-burned and burned particles was performed. Burned particles floats in water while pre-burned particles sank indicated the change of density of the particles. Further improvements of the VTF process in terms of the VTF set-up are required to increase the transformation of glass powders to glass microspheres.

  3. Separation of 90Y from 90Sr by solvent extraction with ionizable crown ethers

    International Nuclear Information System (INIS)

    Wood, D.J.; Elshani, S.; Du, H.S.; Natale, N.R.; Wai, C.M.

    1993-01-01

    Sym-Dibenzo-16-crown-5-oxyacetic acid and its analogues are selective for the extraction of Y 3+ over Sr 2+ from aqueous solutions into chloroform. The selectivity and the pH range of extraction are influenced by the structure of the ligand. The size of the macrocyclic cavity, the tether length of the lariat, the attachment of alkyl functional groups to the lariat, and the identity of the ionizable group can affect selectivity and extraction efficiency. When the carboxylic acid at the terminal end of the lariat is replaced by a hydroxamic acid, the selectivity for Y 3+ over Sr 2+ is significantly increased. Using these ionizable crown ethers as extractants, 90 Y fractions of greater than 99.9% purity can be obtained in a single solvent extraction step from solutions of 90 Sr. 11 refs., 5 figs., 2 tabs

  4. {sup 90}Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction

    Energy Technology Data Exchange (ETDEWEB)

    Carlier, Thomas, E-mail: thomas.carlier@chu-nantes.fr [Department of Nuclear Medicine, University Hospital of Nantes, Place Alexis Ricordeau, Nantes 44093, France and CRCNA–UMR 892 INSERM 6299 CNRS, 8 quai Moncousu BP 70721, Nantes 44007 (France); Willowson, Kathy P. [Institute of Medical Physics, University of Sydney, Camperdown, New South Wales 2006 (Australia); Fourkal, Eugene [Department of Radiation Oncology, Allegheny General Hospital, Pittsburgh, Pennsylvania 15212 (United States); Bailey, Dale L. [Faculty of Health Sciences, University of Sydney, Lidcombe 2141, Australia and Department of Nuclear Medicine, Royal North Shore Hospital, St Leonards, New South Wales 2065 (Australia); Doss, Mohan [Department of Diagnostic Imaging, Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111 (United States); Conti, Maurizio [Siemens Healthcare Molecular Imaging, 810 Innovation Drive, Knoxville, Tennessee 37932 (United States)

    2015-07-15

    Purpose: {sup 90}Y -positron emission tomography (PET) imaging is becoming a recognized modality for postinfusion quantitative assessment following radioembolization therapy. However, the extremely low counts and high random fraction associated with {sup 90}Y -PET may significantly impair both qualitative and quantitative results. The aim of this work was to study image quality and noise level in relation to the quantification and bias performance of two types of Siemens PET scanners when imaging {sup 90}Y and to compare experimental results with clinical data from two types of commercially available {sup 90}Y microspheres. Methods: Data were acquired on both Siemens Biograph TruePoint [non-time-of-flight (TOF)] and Biograph microcomputed tomography (mCT) (TOF) PET/CT scanners. The study was conducted in three phases. The first aimed to assess quantification and bias for different reconstruction methods according to random fraction and number of true counts in the scan. The NEMA 1994 PET phantom was filled with water with one cylindrical insert left empty (air) and the other filled with a solution of {sup 90}Y . The phantom was scanned for 60 min in the PET/CT scanner every one or two days. The second phase used the NEMA 2001 PET phantom to derive noise and image quality metrics. The spheres and the background were filled with a {sup 90}Y solution in an 8:1 contrast ratio and four 30 min acquisitions were performed over a one week period. Finally, 32 patient data (8 treated with Therasphere{sup ®} and 24 with SIR-Spheres{sup ®}) were retrospectively reconstructed and activity in the whole field of view and the liver was compared to theoretical injected activity. Results: The contribution of both bremsstrahlung and LSO trues was found to be negligible, allowing data to be decay corrected to obtain correct quantification. In general, the recovered activity for all reconstruction methods was stable over the range studied, with a small bias appearing at extremely

  5. 90Y and 90Sr separation from hydrochloric acid solutions using TODGA as the extractant by solvent extraction and SLM methods

    International Nuclear Information System (INIS)

    Dutta, S.; Raut, D.R.; Mohapatra, P.K.; Manchanda, V.K.

    2010-01-01

    Yttrium-90 is an important radionuclide known for its therapeutic application in nuclear medicine. It is a pure β-emitter with no associated gamma rays and decays to stable daughter 90 Zr. Suitability of this isotope is because of its short half-life (t 1/2 = 64.2 hrs) and high β emissions (E max = 2.28 MeV. An important source of 90 Y is through the decay of 90 Sr, which produces carrier free isotope. 90 Sr (t 1/2 28 yrs) attains secular equilibrium with 90 Y in a short period and can serve as a long term source for the latter isotope because of relatively long half-life of the parent isotope. Solvent extraction studies with N,N,N',N'-tetra-octyldiglycolamide (TODGA) has shown that Y(III) is well extracted in 6 M HCI while at the same time, extraction of Sr(II) is very low leading to a separation factor (D Y /D Sr = 60,000). This property of TODGA can be exploited for the separation of Y from Sr. In the present work, Supported Liquid Membrane (SLM) based separation of Y and Sr has been explored using TODGA as the carrier

  6. Practical reconstruction protocol for quantitative 90Y bremsstrahlung SPECT/CT

    International Nuclear Information System (INIS)

    Siman, W.; Mikell, J. K.; Kappadath, S. C.

    2016-01-01

    Purpose: To develop a practical background compensation (BC) technique to improve quantitative 90 Y-bremsstrahlung single-photon emission computed tomography (SPECT)/computed tomography (CT) using a commercially available imaging system. Methods: All images were acquired using medium-energy collimation in six energy windows (EWs), ranging from 70 to 410 keV. The EWs were determined based on the signal-to-background ratio in planar images of an acrylic phantom of different thicknesses (2–16 cm) positioned below a 90 Y source and set at different distances (15–35 cm) from a gamma camera. The authors adapted the widely used EW-based scatter-correction technique by modeling the BC as scaled images. The BC EW was determined empirically in SPECT/CT studies using an IEC phantom based on the sphere activity recovery and residual activity in the cold lung insert. The scaling factor was calculated from 20 clinical planar 90 Y images. Reconstruction parameters were optimized in the same SPECT images for improved image quantification and contrast. A count-to-activity calibration factor was calculated from 30 clinical 90 Y images. Results: The authors found that the most appropriate imaging EW range was 90–125 keV. BC was modeled as 0.53× images in the EW of 310–410 keV. The background-compensated clinical images had higher image contrast than uncompensated images. The maximum deviation of their SPECT calibration in clinical studies was lowest (<10%) for SPECT with attenuation correction (AC) and SPECT with AC + BC. Using the proposed SPECT-with-AC + BC reconstruction protocol, the authors found that the recovery coefficient of a 37-mm sphere (in a 10-mm volume of interest) increased from 39% to 90% and that the residual activity in the lung insert decreased from 44% to 14% over that of SPECT images with AC alone. Conclusions: The proposed EW-based BC model was developed for 90 Y bremsstrahlung imaging. SPECT with AC + BC gave improved lesion detectability and activity

  7. Clinical outcomes of Y90 radioembolization for recurrent hepatocellular carcinoma following curative resection

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Rehan; Riaz, Ahsun; Gabr, Ahmed; Abouchaleh, Nadine; Mora, Ronald; Al Asadi, Ali [Northwestern University, Department of Radiology, Section of Interventional Radiology, Chicago, IL (United States); Caicedo, Juan Carlos; Abecassis, Michael; Katariya, Nitin [Northwestern University, Department of Surgery, Division of Transplant Surgery, Chicago, IL (United States); Maddur, Haripriya; Kulik, Laura [Northwestern University, Department of Medicine, Division of Hepatology, Chicago, IL (United States); Lewandowski, Robert J. [Northwestern University, Department of Radiology, Section of Interventional Radiology, Chicago, IL (United States); Northwestern University, Department of Medicine, Division of Hematology and Oncology, Chicago, IL (United States); Salem, Riad [Northwestern University, Department of Radiology, Section of Interventional Radiology, Chicago, IL (United States); Northwestern University, Department of Surgery, Division of Transplant Surgery, Chicago, IL (United States); Northwestern University, Department of Medicine, Division of Hematology and Oncology, Chicago, IL (United States)

    2017-12-15

    To assess safety/efficacy of yttrium-90 radioembolization (Y90) in patients with recurrent hepatocellular carcinoma (HCC) following curative surgical resection. With IRB approval, we searched our prospectively acquired database for patients that were treated with Y90 for recurrent disease following resection. Baseline characteristics and bilirubin toxicities following Y90 were evaluated. Intention-to-treat overall survival (OS) and time-to-progression (TTP) from Y90 were assessed. Forty-one patients met study inclusion criteria. Twenty-six (63%) patients had undergone minor (≤3 hepatic segments) resection while 15 (37%) patients underwent major (>3 hepatic segments) resections. Two patients (5%) had biliary-enteric anastomoses created during surgical resection. The median time from HCC resection to the first radioembolization was 17 months (95% CI: 13-37). The median number of Y90 treatment sessions was 1 (range: 1-5). Ten patients received (entire remnant) lobar Y90 treatment while 31 patients received selective (≤2 hepatic segments) treatment. Grades 1/2/3/4 bilirubin toxicity were seen in nine (22%), four (10%), four (10%), and zero (0%) patients following Y90. No differences in bilirubin toxicities were identified when comparing lobar with selective approaches (P = 0.20). No post-Y90 infectious complications were identified. Median TTP and OS were 11.3 (CI: 6.5-15.5) and 22.1 months (CI: 10.3-31.3), respectively. Radioembolization is a safe and effective method for treating recurrent HCC following surgical resection, with prolonged TTP and promising survival outcomes. (orig.)

  8. Automated characterization of glass microspheres used for laser fusion experiments

    International Nuclear Information System (INIS)

    Tajima, Tsuyoshi; Norimatsu, Takayoshi; Izawa, Yasukazu; Yamanaka, Chiyoe.

    1985-01-01

    In laser fusion experiments glass microspheres of 100 to 1000 μm in diameter and 1 to 20 μm in wall thickness are most commonly used as fuel containers. The glass microspheres should be characterized precisely to meet stringent experimental requirements. Much time is consumed to characterize and select good quality spheres among thousands of spheres. We have developed an automated system to characterize and select glass microspheres. The system consists of charger, quadrupole rail, image processing and X-Y stage control with micro-computer. Total processing time primarily depends on the time required for image analysis, which should be compromised with the accuracy of characterization. The time for simple characterization requires about 10 sec. at present. (author)

  9. Histamine-imprinted microspheres: Comparison between conventional and raft-mediated polymerization techniques

    International Nuclear Information System (INIS)

    Romano, Edwin F. Jr.; So, Regina C.; Holdsworth, Clovia I.

    2015-01-01

    Molecularly imprinted microspheres (MIM) were synthesized via conventional free radical polymerization (CTP) and RAFT-mediated controlled radical polymerization (CRP) method using histamine as the template molecule. Optimal polymerization conditions were achieved using 4%(w/w) monomer feed concentration with 80=90% EGDMA as crosslinker, and histamine: MAA ratio of 1:4 in acetonitrile at 60°C for 24 hours. The size of CTP-M90 and CTP-M80 imprinted microspheres are comparable with that of RAFT polymer CRP-M80 at 264.5 ±12 nm in the swollen (DLS-DMSO) and collapsed state (SEM). For the CTP method, the presence of the template allows for a bigger particle size compared to the non-imprinted counterpart (NIM). Further, controlled growth was observed for the CRP technique, where the size of the imprinted microsphere, CRP-M80, is comparable to CRP-N80. The binding studies of CTP and CRP microspheres toward histamine were studied at concentrations well below biding with buffer concentration of 25mM at pH7. Results showed that the binding isotherms were found to conform to the Freundlich model. Moreover, results revealed that the difference in binding capacity (N) between MIM and NIM imparted by the imprinting process is significantly higher in CTP-80 (26 μmol/g) than both CTP-90 and CRP-80 (9 μmol/g). Non-competitive and competitive binding assays with L-histidine, imidazole, and tryptamine using CTP-80 and CRP-80 were also carried out. MIMs were shown to exhibit binding preference towards the template. (author)

  10. Accumulation of Sr90-Y90 by the developing spawn and larvae of Coregonus lavaretus L

    International Nuclear Information System (INIS)

    Kulikov, N.V.; Ozhegov, L.N.

    1976-01-01

    The results are given of laboratory experiments aimed at studying accumulation of Sr-90 and its daughter product Y-90 in the spawn and larvae of whitefish, a representative of autumn spawning fish species. The results are of interest for predicting possible consequences of radioactive contamination of water bodies and introduction of limits for permissible concentration of radioactive substances in aqueous medium. The accumulation coefficient of Sr-90 in the spawn reaches its maximum after the first twenty four hours of the experiment. Subsequently throughout the incubation period the accumulation coefficient (AC) of radionuclide does not undergo any changes being about 3. Besides it has been established that the equilibrium distribution of Sr-90 in whitefish spawn and the surrounding solution occurs during the first two hours. Unlike Sr-90 the accumulation of Y-90 occurs during the whole incubation period and results in the AC value of 80 by the end of the spawn incubation. The experiments aimed at determining the strength of radionuclide fixation by whitefish spawn and larvae revealed that both radionuclides in the spawn are rather mobile. Strontium separates fully from it during the first twenty four hours and yttrium marked by higher fixation strength transfers completely from the spawn into surrounding aqueous medium by the end of the experiment. In larvae the radionuclides are fixed stroger than in the spawn. The approximate radiation doses of embryos by the time of their hatching have been estimated. The estimates indicate that the total radiation dose of the spawn developing in aqueous solution of Sr-90 - Y-90 with 1.1 curie/0 -5 concentration is about 500 radl

  11. The physical and chemical stability of suspensions of sustained-release diclofenac microspheres.

    Science.gov (United States)

    Lewis, L; Boni, R L; Adeyeye, C M

    1998-01-01

    The major challenge in liquid sustained-release oral suspensions is to minimize drug diffusion into the suspending medium and to retain the original properties of the microparticles during storage. Diclofenac wax microspheres prepared by the hydrophobic congealable disperse phase method were formulated as a sustained release suspension and stored at three different temperatures (25, 37 and 45 degrees C) for 3 months, to evaluate the physical and chemical stability of the suspended microspheres. Suspensions of microspheres stored at ambient temperatures were both physically and chemically stable, but at higher temperatures, up to 45 degrees C, there was a decrease in drug release due to scaling and melting on the microsphere surface as observed by scanning electron microscopy. However, on prolonged storage, up to 90 days, especially at 45 degrees C, temperature became a dominant factor causing an increase in drug release. The suspension of diclofenac microspheres was chemically stable for 3 months, while the plain drug suspension exhibited slight degradation.

  12. Radiolabeling, characterization and preliminary studies of 90Y-octreotate

    International Nuclear Information System (INIS)

    Klementyeva, O.E.; Bruskin, A.B.; Larenkov, A.A.; Kodina, G.E.; Korsunsky, V.N.

    2015-01-01

    Full text of publication follows. Introduction: Overexpression of the somatostatin receptors in neuroendocrine tumors has become the molecular basis for the use of somatostatin analogues in diagnosis and therapy for these neoplasms. The high energy (maximum 2.2 MeV) and penetration range (R 95 5.7 mm) of β-particles from 90 Y are advantageous, with a direct killing of somatostatin receptor positive cells and a crossfire effect which hits nearby receptor-negative tumour cells [Ref. 1]. Aim: the investigation of the reaction conditions for the preparation of 90 Y-Octreotate and its in vitro characterization. Materials and methods: DOTA-Octreotate (Farm-Syntez Ltd.) and 88 YCl 3 (V/O Isotop) were used without purification. 88 Y-Octreotate was prepared in acetate buffer solution and its radiochemical purity was controlled by ITLC. In-vitro experiments were carried out with melanoma B16. Studies of internalization were performed as described in [Ref. 2]. Results: the maximal accumulation in the cells was observed after 90 min from the beginning of incubation and was about 3.9%. In our experiments, we found high level of internalization of the surface-bound 88 Y-Octreotate into B16 cells. Maximal internalization level was 80% after 60 min of incubation. Conclusion: the optimal conditions for effective labeling (> 95%) of DOTA-Octreotate were found. The results obtained using the gamma-emitting 88 Y, provide a basis for in vivo research 90 Y octreotate as radiotherapeutic agent. References: [Ref. 1] Bodei, L.; Pepe, G.; Paganelli, G.; Peptide receptor radionuclide therapy (PRRT) of neuroendocrine tumors with somatostatin analogues. Eur. Rev. Med. Pharmacol. Sci., 2010; v. 14: 347-351. [Ref. 2] Garcia Garayoa E., Allemann-Tannahill L., et al. In vitro and in vivo evaluation of new radiolabeled neurotensin (8-13) analogs with high affinity for NT1 receptors. Nucl. Med. Biol. 2001; 28: 75-84. (authors)

  13. A sonochemical route for the encapsulation of drug in magnetic microspheres

    International Nuclear Information System (INIS)

    Wu Shixi; Jiang Wei; Zhang Xiaojuan; Sun Huan; Zhang Wenyao; Dai Junjun; Liu Li; Chen Xiaolong; Li Fengsheng

    2012-01-01

    This study focused on the preparation and characterization of magnetic targeted antibiotic microspheres (MTAMs). MTAMs were prepared by a sonochemical method in the presence of hydrophobic Fe 3 O 4 nanoparticles and tetracycline. The properties of MTAMs were characterized by transmission electron microscopy, Fourier-transform infrared spectrum, thermogravimetric analysis, vibration sample magnetometry, and bacteriostatic experiment. The results indicated that the superparamagnetic microspheres have ultrafine size (below 230 nm), high saturation magnetization (80.90 emu/g), high biocompatibility, biodegradability, controlled-release, and antibiotic effect. It has been proved that MTAMs can carry out the function of magnetic targeted drugs delivery system by putting together magnetic materials and antibiotics. The possible formation mechanism of MTAMs was also discussed. In summary, MTAMs had potential in medical imaging, drug targeting, and catalysis. - Highlights: → Microspheres carry out the function of magnetic targeted drugs delivery system. → Microspheres exhibit high saturation magnetization and antibiotic effect. → Microspheres have a potential application in the biomedical field. → The sonochemical method is well controlled for the synthesis.

  14. Flexible Microsphere-Embedded Film for Microsphere-Enhanced Raman Spectroscopy.

    Science.gov (United States)

    Xing, Cheng; Yan, Yinzhou; Feng, Chao; Xu, Jiayu; Dong, Peng; Guan, Wei; Zeng, Yong; Zhao, Yan; Jiang, Yijian

    2017-09-27

    Dielectric microspheres with extraordinary microscale optical properties, such as photonic nanojets, optical whispering-gallery modes (WGMs), and directional antennas, have drawn interest in many research fields. Microsphere-enhanced Raman spectroscopy (MERS) is an alternative approach for enhanced Raman detection by dielectric microstructures. Unfortunately, fabrication of microsphere monolayer arrays is the major challenge of MERS for practical applications on various specimen surfaces. Here we report a microsphere-embedded film (MF) by immersing a highly refractive microsphere monolayer array in the poly(dimethylsiloxane) (PDMS) film as a flexible MERS sensing platform for one- to three-dimensional (1D to 3D) specimen surfaces. The directional antennas and wave-guided whispering-gallery modes (WG-WGMs) contribute to the majority of Raman enhancement by the MFs. Moreover, the MF can be coupled with surface-enhanced Raman spectroscopy (SERS) to provide an extra >10-fold enhancement. The limit of detection is therefore improved for sensing of crystal violet (CV) and Sudan I molecules in aqueous solutions at concentrations down to 10 -7 M. A hybrid dual-layer microsphere enhancer, constructed by depositing a MF onto a microsphere monolayer array, is also demonstrated, wherein the WG-WGMs become dominant and boost the enhancement ratio >50-fold. The present work opens up new opportunities for design of cost-effective and flexible MERS sensing platforms as individual or associated techniques toward practical applications in ultrasensitive Raman detection.

  15. Multi institutional quantitative phantom study of yttrium-90 PET in PET/MRI: the MR-QUEST study.

    Science.gov (United States)

    Maughan, Nichole M; Eldib, Mootaz; Faul, David; Conti, Maurizio; Elschot, Mattijs; Knešaurek, Karin; Leek, Francesca; Townsend, David; DiFilippo, Frank P; Jackson, Kimberly; Nekolla, Stephan G; Lukas, Mathias; Tapner, Michael; Parikh, Parag J; Laforest, Richard

    2018-04-04

    Yttrium-90 ( 90 Y) radioembolization involves the intra-arterial delivery of radioactive microspheres to treat hepatic malignancies. Though this therapy involves careful pre-treatment planning and imaging, little is known about the precise location of the microspheres once they are administered. Recently, there has been growing interest post-radioembolization imaging using positron-emission tomography (PET) for quantitative dosimetry and identifying lesions that may benefit from additional salvage therapy. In this study, we aim to measure the inter-center variability of 90 Y PET measurements as measured on PET/MRI in preparation for a multi-institutional prospective phase I/II clinical trial. Eight institutions participated in this study and followed a standardized phantom filling and imaging protocol. The NEMA NU2-2012 body phantom was filled with 3 GBq of 90 Y chloride solution. The phantom was imaged for 30 min in listmode on a Siemens Biograph mMR non-TOF PET/MRI scanner at five time points across 10 days (0.3-3.0 GBq). Raw PET data were sent to a central site for image reconstruction and data analysis. Images were reconstructed with optimal parameters determined from a previous study. Volumes of interest (VOIs) matching the known sphere diameters were drawn on the vendor-provided attenuation map and propagated to the PET images. Recovery coefficients (RCs) and coefficient of variation of the RCs (COV) were calculated from these VOIs for each sphere size and activity level. Mean RCs ranged from 14.5 to 75.4%, with the lowest mean RC coming from the smallest sphere (10 mm) on the last day of imaging (0.16 MBq/ml) and the highest mean RC coming from the largest sphere (37 mm) on the first day of imaging (2.16 MBq/ml). The smaller spheres tended to exhibit higher COVs. In contrast, the larger spheres tended to exhibit lower COVs. COVs from the 37 mm sphere were  25%. Post-radioembolization dosimetry of lesions or other VOIs ≥ 22 mm in diameter can

  16. Radiolabeling oligo nuclieotide with 90Y and its radiolysis

    International Nuclear Information System (INIS)

    Liu Changbin; Tian Jiahe; Zhang Jinming; Yin Dayi; Guo Zhe

    2005-01-01

    Objective: To evaluate labeling Morpholinos (MORF), a DNA analogue, with 90 Y using p-isothiocyanatobenzyl-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) as chelater and assess its stability and hybridization in vitro. Methods: A 25 mer MORF with a primary amine on the 3' equivalent end attached via a 10 member linker was conjugated with an isothiocyanate backbone derivative of DOTA. The conjugated product was labeled in various buffers over a different range of concentrations (0.5-2 mol/L) and pH(3-8.5). The labeled MORF was investigated for stability and hybridization in vitro. Results: By size exclusion high performance liquid chromatogram (HPLC) and instant thin layer chromatography (ITLC) analysis, the DOTA conjugated MORF was successfully radiolabeled, the labeling efficiency was (50 ± 12)%, the specific radioactivity was 5.05 x 10 6 MBq/mmol, radiochemistry purity >95%. The labeled MORF showed one sharp peak by HPLC that shifted completely to earlier retention times following addition of a polymer conjugated with the complementary MORF. In saline at room temperature and in serum at 37 degree C, the radioactivity profile of 90 Y showed a pronounced lower molecular weight peak which did not shifted and was shown due to 90 Y-DOTA resulting from radiolysis. Conclusion: MORF can be successfully labeled with 90 Y via DOTA as chelater, but care it must be taken to avoid the effect of radiolysis. (authors)

  17. Oxaliplatin loaded PLAGA microspheres: design of specific release profiles.

    Science.gov (United States)

    Lagarce, F; Cruaud, O; Deuschel, C; Bayssas, M; Griffon-Etienne, G; Benoit, J

    2002-08-21

    Oxaliplatin loaded PLAGA microspheres have been prepared by solvent extraction process. Parameters affecting the release kinetics in vitro have been studied in order to design specific release profiles suitable for direct intra-tumoral injection. By varying the nature and the relative proportions of different polymers we managed to prepare microspheres with good encapsulation efficiency (75-90%) and four different release profiles: zero order kinetics (type II) and the classical sigmoïd release profile with three different sizes of plateau and burst. These results, if correlated with in vivo activity, are promising to enhance effectiveness of local tumor treatment.

  18. Country report: India. Development of Radiopharmaceuticals Based on 188Re and 90Y for Radionuclide Therapy

    International Nuclear Information System (INIS)

    Venkatesh, M.; Pandey, U.; Dhami, P.S.; Chakravarty, R.; Kameswaran, M.; Subramanian, S.; Dash, A.; Samuel, G.

    2010-01-01

    During the past decade, our group has focused attention on the development of therapeutic radiopharmaceuticals incorporating radioisotopes such as 90 Y, 188 Re etc. As the primary source of the radioisotopes 90 Y and 188 Re are the 90 Sr/ 90 Y generators and 188 W/ 188 Re generators respectively, the local availability of these generator systems is very important for the successful development of radiopharmaceuticals incorporating these radioisotopes. In this context, 90 Sr/ 90 Y generators based on Supported Liquid Membrane (SLM) [1-3] and electrochemical techniques [4] could be designed and deployed in our laboratories for the elution of 90 Y to be used for preparation of 90 Y labeled products. This work formed a part of the IAEA co-ordinated CRP on “Development of Generator Technologies for Therapeutic Radionuclides: 90 Y and 188 Re”. In this report, work on the development of 90 Y radiopharmaceuticals for treatment of liver cancer and non-Hodgkin’s lymphoma (NHL) is reported. In addition, comparison of the Extraction Paper Chromatography technique (EPC) developed for determination of 90 Sr contamination in 90 Y samples with the US Pharmacopeia recommended method as well as the validation of the EPC technique is presented

  19. Quantitative and qualitative assessment of Yttrium-90 PET/CT imaging.

    Directory of Open Access Journals (Sweden)

    Ali Asgar Attarwala

    Full Text Available Yttrium-90 is known to have a low positron emission decay of 32 ppm that may allow for personalized dosimetry of liver cancer therapy with (90Y labeled microspheres. The aim of this work was to image and quantify (90Y so that accurate predictions of the absorbed dose can be made. The measurements were performed within the QUEST study (University of Sydney, and Sirtex Medical, Australia. A NEMA IEC body phantom containing 6 fillable spheres (10-37 mm ∅ was used to measure the 90Y distribution with a Biograph mCT PET/CT (Siemens, Erlangen, Germany with time-of-flight (TOF acquisition. A sphere to background ratio of 8:1, with a total (90Y activity of 3 GBq was used. Measurements were performed for one week (0, 3, 5 and 7 d. he acquisition protocol consisted of 30 min-2 bed positions and 120 min-single bed position. Images were reconstructed with 3D ordered subset expectation maximization (OSEM and point spread function (PSF for iteration numbers of 1-12 with 21 (TOF and 24 (non-TOF subsets and CT based attenuation and scatter correction. Convergence of algorithms and activity recovery was assessed based on regions-of-interest (ROI analysis of the background (100 voxels, spheres (4 voxels and the central low density insert (25 voxels. For the largest sphere, the recovery coefficient (RC values for the 30 min -2-bed position, 30 min-single bed and 120 min-single bed were 1.12 ± 0.20, 1.14 ± 0.13, 0.97 ± 0.07 respectively. For the smaller diameter spheres, the PSF algorithm with TOF and single bed acquisition provided a comparatively better activity recovery. Quantification of Y-90 using Biograph mCT PET/CT is possible with a reasonable accuracy, the limitations being the size of the lesion and the activity concentration present. At this stage, based on our study, it seems advantageous to use different protocols depending on the size of the lesion.

  20. Radiation Safety in Production of Y-90 from an electrochemical generator. CENTIS experience

    International Nuclear Information System (INIS)

    Ayra Pardo, Fernando Enrique

    2016-01-01

    From a project with the International Atomic Energy Agency, Isotope Center installation and commissioning began operating an electrochemical generator of Sr-90 / Y-90 inside a glove box shielded. The aim was to ensure the production of Y-90 needed in the research carried out in Cuba with this radionuclide for the medical industry. Associate at the beginning of this practice, compliance with all regulatory requirements approved in the country from the radiological point of view that demonstrated the safety of this for both operators and the general public became necessary. Using the MCNPX code generator installation was simulated and the equivalent dose Hp (10) were obtained for the operator: 6.27 mSv / y Hp (0.07): 17 mSv / a for a source of 10 Ci of 90 Sr- 90 Y . Also the use of TLD dosimeters similar to those used for gamma emitting radionuclides for controlling beta exposures was evaluated. high sensitivity lithium fluoride tablets couple energy beta particles of Y-90 which ensures its use for measuring the magnitude Hp (007) was demonstrated. two possible solutions for the recovery of liquid waste 90 Sr one another by distillation and ion exchange are evaluated. To transport the Y-90 may be used the package currently used in marketing the rest of the CENTIS radiopharmaceuticals. As a final result, the practice was approved and included in the Operating License Center Isotopes. (author)

  1. Monte Carlo simulation of PET and SPECT imaging of {sup 90}Y

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Akihiko, E-mail: takahsr@hs.med.kyushu-u.ac.jp; Sasaki, Masayuki [Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Himuro, Kazuhiko; Yamashita, Yasuo; Komiya, Isao [Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Baba, Shingo [Department of Clinical Radiology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan)

    2015-04-15

    Purpose: Yittrium-90 ({sup 90}Y) is traditionally thought of as a pure beta emitter, and is used in targeted radionuclide therapy, with imaging performed using bremsstrahlung single-photon emission computed tomography (SPECT). However, because {sup 90}Y also emits positrons through internal pair production with a very small branching ratio, positron emission tomography (PET) imaging is also available. Because of the insufficient image quality of {sup 90}Y bremsstrahlung SPECT, PET imaging has been suggested as an alternative. In this paper, the authors present the Monte Carlo-based simulation–reconstruction framework for {sup 90}Y to comprehensively analyze the PET and SPECT imaging techniques and to quantitatively consider the disadvantages associated with them. Methods: Our PET and SPECT simulation modules were developed using Monte Carlo simulation of Electrons and Photons (MCEP), developed by Dr. S. Uehara. PET code (MCEP-PET) generates a sinogram, and reconstructs the tomography image using a time-of-flight ordered subset expectation maximization (TOF-OSEM) algorithm with attenuation compensation. To evaluate MCEP-PET, simulated results of {sup 18}F PET imaging were compared with the experimental results. The results confirmed that MCEP-PET can simulate the experimental results very well. The SPECT code (MCEP-SPECT) models the collimator and NaI detector system, and generates the projection images and projection data. To save the computational time, the authors adopt the prerecorded {sup 90}Y bremsstrahlung photon data calculated by MCEP. The projection data are also reconstructed using the OSEM algorithm. The authors simulated PET and SPECT images of a water phantom containing six hot spheres filled with different concentrations of {sup 90}Y without background activity. The amount of activity was 163 MBq, with an acquisition time of 40 min. Results: The simulated {sup 90}Y-PET image accurately simulated the experimental results. PET image is visually

  2. Dosimetry characterization of the commercial CaF2 for beta radiation of 90Sr + 90Y

    International Nuclear Information System (INIS)

    Oliveira, Mercia L.; Caldas, Linda V.E.

    2003-01-01

    This work studies the dosimetric characteristics of the CaF 2 commercial dosimetry for detection of 90 Sr + 90 Y beta radiation for using in the calibration of flat and concave appliers. Were determined the repetitiousness and linearity of answers of the samples, and their calibration curves

  3. Clinical results of radionuclide therapy of neuroendocrine tumours with {sup 90}Y-DOTATATE and tandem {sup 90}Y/{sup 177}Lu-DOTATATE: which is a better therapy option?

    Energy Technology Data Exchange (ETDEWEB)

    Kunikowska, Jolanta; Krolicki, Leszek [Medical University of Warsaw, Nuclear Medicine Department, Warsaw (Poland); Hubalewska-Dydejczyk, Alicja; Sowa-Staszczak, Anna [Collegium Medicum Cracow, Cracow (Poland); Mikolajczak, Renata; Pawlak, Dariusz [Institute of Atomic Energy POLATOM, Swierk-Otwock (Poland)

    2011-10-15

    Peptide receptor radionuclide therapy (PRRT) using radiolabelled somatostatin analogues is a treatment option for patients with disseminated neuroendocrine tumours (NET). A combination treatment using the high-energy {sup 90}Y beta emitter for larger lesions and the lower energy {sup 177}Lu for smaller lesions has been postulated in the literature.The aim of the study was to evaluate combined {sup 90}Y/{sup 177}Lu-DOTATATE therapy in comparison to {sup 90}Y-DOTATATE alone. Fifty patients with disseminated NET were included in the study prospectively and divided into two groups: group A (n = 25) was treated with {sup 90}Y-DOTATATE, whereas group B (n = 25) received the 1:1 {sup 90}Y/{sup 177}Lu-DOTATATE. The administered activity was based on 3.7 GBq/m{sup 2} body surface area in three to five cycles, with amino acid infusion for nephroprotection. The median overall survival time in group A was 26.2 months while in group B median survival was not reached. Overall survival was significantly higher in group B (p = 0.027). Median event-free survival time in group A was 21.4 months and in group B 29.4 months (p > 0.1). At the 12-month follow-up, comparison of group A vs group B showed stable disease (SD) in 13 vs 16 patients, disease regression (RD) in 5 vs 3 patients and disease progression (PD) in 3 vs 4 patients; 4 and 2 patients died, respectively. The 24-month follow-up results were SD in nine vs ten patients, RD in one patient vs none and PD in four patients in both groups; three and four patients died, respectively. Side effects were rare and mild. The results indicate that therapy with tandem radioisotopes ({sup 90}Y/{sup 177}Lu-DOTATATE) provides longer overall survival than with a single radioisotope ({sup 90}Y-DOTATATE) and the safety of both methods is comparable. (orig.)

  4. Practical reconstruction protocol for quantitative {sup 90}Y bremsstrahlung SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Siman, W.; Mikell, J. K.; Kappadath, S. C., E-mail: skappadath@mdanderson.org [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 and The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, Texas 77030 (United States)

    2016-09-15

    Purpose: To develop a practical background compensation (BC) technique to improve quantitative {sup 90}Y-bremsstrahlung single-photon emission computed tomography (SPECT)/computed tomography (CT) using a commercially available imaging system. Methods: All images were acquired using medium-energy collimation in six energy windows (EWs), ranging from 70 to 410 keV. The EWs were determined based on the signal-to-background ratio in planar images of an acrylic phantom of different thicknesses (2–16 cm) positioned below a {sup 90}Y source and set at different distances (15–35 cm) from a gamma camera. The authors adapted the widely used EW-based scatter-correction technique by modeling the BC as scaled images. The BC EW was determined empirically in SPECT/CT studies using an IEC phantom based on the sphere activity recovery and residual activity in the cold lung insert. The scaling factor was calculated from 20 clinical planar {sup 90}Y images. Reconstruction parameters were optimized in the same SPECT images for improved image quantification and contrast. A count-to-activity calibration factor was calculated from 30 clinical {sup 90}Y images. Results: The authors found that the most appropriate imaging EW range was 90–125 keV. BC was modeled as 0.53× images in the EW of 310–410 keV. The background-compensated clinical images had higher image contrast than uncompensated images. The maximum deviation of their SPECT calibration in clinical studies was lowest (<10%) for SPECT with attenuation correction (AC) and SPECT with AC + BC. Using the proposed SPECT-with-AC + BC reconstruction protocol, the authors found that the recovery coefficient of a 37-mm sphere (in a 10-mm volume of interest) increased from 39% to 90% and that the residual activity in the lung insert decreased from 44% to 14% over that of SPECT images with AC alone. Conclusions: The proposed EW-based BC model was developed for {sup 90}Y bremsstrahlung imaging. SPECT with AC + BC gave improved lesion

  5. Thermoluminescent dosimetry of beta radiations of 90 Sr/ 90 Y using ZrO2: Eu

    International Nuclear Information System (INIS)

    Olvera T, L.; Azorin N, J.; Barrera S, M.; Soto E, A.M.; Rivera M, T.

    2005-01-01

    In this work the results of studying the thermoluminescent properties (TL) of the doped zirconium oxide with europium (ZrO 2 : Eu 3+ ) before beta radiations of 90 Sr/ 90 Y are presented. The powders of ZrO 2 : Eu 3+ were obtained by means of the sol-gel technique and they were characterized by means of thermal analysis and by X-ray diffraction. The powders of ZrO 2 : Eu 3+ , previously irradiated with beta particles of 90 Sr/ 90 Y, presented a thermoluminescent curve with two peaks at 204 and 292 C respectively. The TL response of the ZrO 2 : Eu 3+ as function of the absorbed dose was lineal from 2 Gy up to 90 Gy. The fading of the information of the ZrO 2 : Eu 3+ was of 10% the first 2 hours remaining almost constant the information by the following 30 days. The ZrO 2 doped with the (Eu 3+ ) ion it was found more sensitive to the beta radiation that the one of zirconium oxide without doping (ZrO 2 ) obtained by the same method. Those studied characteristics allow to propose to the doped zirconium oxide with europium like thermoluminescent dosemeter for the detection of the beta radiation. (Author)

  6. Depth dose curves from 90Sr+90Y clinical applicators using the thermoluminescent technique

    International Nuclear Information System (INIS)

    Antonio, Patricia L.; Caldas, Linda V.E.; Oliveira, Mercia L.

    2009-01-01

    The 90 Sr+ 90 Y beta-ray sources widely used in brachytherapy applications were developed in the 1950's. Many of these sources, called clinical applicators, are still routinely used in several Brazilian radiotherapy clinics for the treatment of superficial lesions in the skin and eyes, although they are not commercialized anymore. These applicators have to be periodically calibrated, according to international recommendations, because these sources have to be very well specified in order to reach the traceability of calibration standards. In the case of beta-ray sources, the recommended quantity is the absorbed dose rate in water at a reference distance from the source. Moreover, there are other important quantities, as the depth dose curves and the source uniformity for beta-ray plaque sources. In this work, depth dose curves were obtained and studied of five dermatological applicators, using thin thermoluminescent dosimeters of CaSO 4 :Dy and phantoms of PMMA with different thicknesses (between 1.0 mm and 5.0 mm) positioned between each applicator and the TL pellets. The depth dose curves obtained presented the expected attenuation response in PMMA, and the results were compared with data obtained for a 90 Sr+ 90 Y standard source reported by the IAEA, and they were considered satisfactory. (author)

  7. SU-G-201-12: Investigation of Beta-Emitter 90Sr-90Y Dose Distribution Using Gafchromic EBT3 Film for Application On Conformal Skin Brachytherapy Device

    International Nuclear Information System (INIS)

    Ferreira, C; Johnson, D; Ahmad, S; Rasmussen, K; Jung, J

    2016-01-01

    Purpose: To investigate 90 Sr- 90 Y as a high dose rate (HDR) source for application in a conformal skin brachytherapy (CSBT) device. The CSBT device has been previously developed to provide patient specific treatment for small inoperable lesions and irregular surfaces. Methods: A popular beta emitter, 90 Sr- 90 Y was tested for feasibility in a CSBT device. A 1 cm diameter plaque was used to deliver dose to a solid water phantom containing EBT3 Gafchromic films arranged at the surface and perpendicular to it. Additionally, a 1 cm diameter 6 MeV electron beam was used to irradiate EBT3 film at 100 cm SSD with a 0.5 cm bolus. Films were digitized with an Epson Expression 10000 XL scanner and calibrated with a 6 MeV electron specific dose curve. Normalized percent depth doses (PDD) and dose profiles for both techniques were analyzed using ImageJ. Results: Dose distributions achieved with the 90 Sr- 90 Y sources were compared with those of external electron beam radiation therapy (EBRT). Penumbra (20%- 80%) for EBRT and 90Sr-90Y were 4.3 mm and 1.6 mm, respectively. PDD values of 50% (normalized to 2 mm) were 10.1 mm and 2.8 mm for electron and 90 Sr- 90 Y, respectively. Flatness (80% of the central beam profile) was 14.1% at a 5 mm depth for EBRT and 4.0% at surface for the 90 Sr- 90 Y. Conclusion: As expected, the PDDs of 90 Sr- 90 Y in water are shallower than that of external electron beams for the same field size. 90 Sr- 90 Y can be used in CSBT to provide patient specific treatment where shallower depth doses than that provided by electron external beams may be required: e.g. eyelids, nose, lips, ears, etc. The customizability of EBRT could be replicated by using multiple adjacent 90 Sr- 90 Y plaque placements.

  8. SU-G-201-12: Investigation of Beta-Emitter 90Sr-90Y Dose Distribution Using Gafchromic EBT3 Film for Application On Conformal Skin Brachytherapy Device

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, C; Johnson, D; Ahmad, S [University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States); Rasmussen, K [University of Texas HSC SA, San Antonio, TX (United States); Jung, J [East Carolina University Greenville, NC (United States)

    2016-06-15

    Purpose: To investigate {sup 90}Sr-{sup 90}Y as a high dose rate (HDR) source for application in a conformal skin brachytherapy (CSBT) device. The CSBT device has been previously developed to provide patient specific treatment for small inoperable lesions and irregular surfaces. Methods: A popular beta emitter, {sup 90}Sr-{sup 90}Y was tested for feasibility in a CSBT device. A 1 cm diameter plaque was used to deliver dose to a solid water phantom containing EBT3 Gafchromic films arranged at the surface and perpendicular to it. Additionally, a 1 cm diameter 6 MeV electron beam was used to irradiate EBT3 film at 100 cm SSD with a 0.5 cm bolus. Films were digitized with an Epson Expression 10000 XL scanner and calibrated with a 6 MeV electron specific dose curve. Normalized percent depth doses (PDD) and dose profiles for both techniques were analyzed using ImageJ. Results: Dose distributions achieved with the {sup 90}Sr-{sup 90}Y sources were compared with those of external electron beam radiation therapy (EBRT). Penumbra (20%- 80%) for EBRT and 90Sr-90Y were 4.3 mm and 1.6 mm, respectively. PDD values of 50% (normalized to 2 mm) were 10.1 mm and 2.8 mm for electron and {sup 90}Sr-{sup 90}Y, respectively. Flatness (80% of the central beam profile) was 14.1% at a 5 mm depth for EBRT and 4.0% at surface for the {sup 90}Sr-{sup 90}Y. Conclusion: As expected, the PDDs of {sup 90}Sr-{sup 90}Y in water are shallower than that of external electron beams for the same field size. {sup 90}Sr-{sup 90}Y can be used in CSBT to provide patient specific treatment where shallower depth doses than that provided by electron external beams may be required: e.g. eyelids, nose, lips, ears, etc. The customizability of EBRT could be replicated by using multiple adjacent {sup 90}Sr-{sup 90}Y plaque placements.

  9. 90Y production of high purity by electrochemical separation

    International Nuclear Information System (INIS)

    Alberti Ramírez, Alejandro; Serra Águila, Rolando; Morín Zorrilla, José Antonio; Pino Peraza, Madián; Soler Iglesias, Joel; Cruz Morales, Amed

    2016-01-01

    In this paper 90 Y is obtained without added carrier, by electrolytic separation from a solution in secular equilibrium Sr-Y and further purification in three cycles electrolytic automated, at constant current. The process productivity was 60-80 mCi (2220-2960 MBq). The long half-life of 90 Sr to be used by virtually indefinitely ensuring the stability of the raw material for generator operation, which helps sustainability and production stability. In 18 productions to date could be found to both content of 90 Sr equal to 0.110 ± 0.004 (k = 2) kBq / g by various methods, for their ability combination with DTPA, bifunctional chelate appropriate range of concentrations and even in the presence of trace metals, resulting in excellent characteristics for use as precursor in the preparation of therapeutic radiopharmaceuticals including radioimmunotherapy. The latter being a pure beta emitter with physical half-life, comparable to the time of capture and residence of many antibodies in tumors. The influence of Fe (III) was studied by the method of addition and concluded that only affects the performance of DTPA 90 Y marking if their presence is above a concentration of 0.018 mol / L. We show that the presence of other metals such as Pb (II), Zn (II) and Cu (II) also affects performance complexation

  10. Effect of crosslinking agents on chitosan microspheres in controlled release of diclofenac sodium

    Directory of Open Access Journals (Sweden)

    Vanessa L. Gonçalves

    2005-03-01

    Full Text Available In this work chitosan microspheres were prepared by the simple coacervation method and crosslinked using epichlorhydrin or glutaraldehyde for the controlled release of diclofenac sodium. The effects of the crosslinking agents on chitosan microspheres over a 12-hour period were assessed with regard to swelling, hydrolysis, porosity, crosslinking, impregnation of diclofenac sodium (DS, and consequently to the release of DS in buffer solutions, simulating the gastrointestinal tract. The degree of swelling varied with the pH for glutaraldehyde chitosan microspheres (GCM and epichlorhydrin chitosan microspheres (ECM. Partial acid and basic hydrolysis affected the swelling behavior of the GCM matrix. Release kinetics of diclofenac sodium from these matrices were investigated at pH 1.2, 6.8 and 9.0, simulating the gastrointestinal tract conditions. The results indicated that the release mechanism deviated slightly from Fickian transport.

  11. Dosimetry characterization of the commercial CaF{sub 2} for beta radiation of {sup 90}Sr + {sup 90}Y; Caracterizacao dosimetrica de CaF{sub 2} comercial para radiacao beta de {sup 90}Sr + {sup 90}Y

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Mercia L.; Caldas, Linda V.E. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)], e-mail: mlolivei@ipen.br, e-mail: lcaldas@ipen.br

    2003-07-01

    This work studies the dosimetric characteristics of the CaF{sub 2} commercial dosimetry for detection of {sup 90}Sr + {sup 90}Y beta radiation for using in the calibration of flat and concave appliers. Were determined the repetitiousness and linearity of answers of the samples, and their calibration curves.

  12. An Overview of the Production, Quality Control and Feasibility of Using 90Y as a Therapeutic Radionuclide

    International Nuclear Information System (INIS)

    Venkatesh, M.

    2009-01-01

    90 Y is increasingly accepted world wide as a radionuclide for in-vivo therapy owing to attractive decay features (T1/2 2.67 d; Eβ max 2.28 MeV) and viable production feasibility in high specific activities. 90 Y is most often recommended for treatment of large tumour lesions as the hard β rays are effective in delivering therapeutic dose to large volume. However, possibility of high radiation dose to the critical organs such as bone marrow and kidneys is an important concern that is given due weightage while designing therapy using 90 Y. The best route to avail 90 Y for therapy applications is from 90 Sr, though neutron actiation of natural 89 Y(100% abundance) is feasible. The absorption cross section σ is barely 1.38 b, resulting in low specific activity 90 Y which is useful for limited applications. The possibility of obtaining 90Y through a radionuclide generator as the daughter of a long lived parent 90 Sr (T1/2 28.9 y) is a major advantage that enables access to high specific activity 90 Y. Transporting the 90Y activity to a user institution from a centralized production facility is reasonably feasible and this facilitates its wide spread use. Several generator designs have been developed and reported to access 90 Y. Solvent extraction using a chelating molecule in an organic solvent (0.3M HDEHP/n-dodecane), column chromatography using ion exchange resins (cationic as well as anionic; Dowex-50x8; AG 50x16; Aminex-A5) or inorganic exchanger, membrane based separation using chelating ligand impregnated membranes (CMPO in electrochemical separation are some of the methods reported. Limitations such as elution of 90 Y after initial elution of 90 Sr, availability of 90 Y as a chelated complex which then has to be treated to enable labeling the molecule of interest, possibility of obtaining small quantities of 90 Y owing to radiolytic damages to the separation system components, paucity of special automation gadgets for handling the high activities remotely

  13. Radiation protection in radionuclide therapies with (90)Y-conjugates: risks and safety.

    Science.gov (United States)

    Cremonesi, Marta; Ferrari, Mahila; Paganelli, Giovanni; Rossi, Annalisa; Chinol, Marco; Bartolomei, Mirco; Prisco, Gennaro; Tosi, Giampiero

    2006-11-01

    The widespread interest in (90)Y internal radionuclide treatments has drawn attention to the issue of radiation protection for staff. Our aim in this study was to identify personnel at risk and to validate the protection devices used. (90)Y-MoAb (Zevalin, 15 cases, 1.1 GBq/patient) and (90)Y-peptide ((90)Y-DOTATOC) systemic (i.v., 50 cases, 3.0 GBq/patient) and locoregional (l.r., 50 cases, 0.4 GBq/patient) treatments were considered. Radiolabelling was carried out in a dedicated hot cell. Tele-tongs, shielded (PMMA: polymethylmethacrylate) syringes/vials and an automatic dose fractionating system were used. Operators wore anti-X-ray and anti-contamination gloves, with TLD dosimeters placed over the fingertips. For i.v. administration, activity was administered by a dedicated system; for l.r. administration, during activity infusion in the brain cavity, tongs were used and TLDs were placed over the fingertips. The air kerma-rate was measured around the patients. The use of devices provided a 75% dose reduction, with mean fingertip doses of 2.9 mGy (i.v. MoAbs), 0.6 mGy (i.v. peptides)/radiolabelling procedure and 0.5 mGy/l.r. administration. The mean effective dose to personnel was 5 microSv/patient. The air kerma-rate around the patients administered i.v. (90)Y-peptides were 3.5 (1 h) and 1.0 (48 h) microGy/h at 1 m. Patient hospitalisation of 6 h (l.r.)/48 h (i.v.) guaranteed that the recommended limits of 3 mSv/year to family members and 0.3 mSv/year to the general population (Council Directive 97/43/Euratom) were respected. When specific procedures are adopted, a substantial improvement in (90)Y manipulation is attainable, reducing doses and increasing safety. For the widespread clinical use of (90)Y-conjugates, a completely automatic labelling procedure is desirable.

  14. Fluorescent probe encapsulated hydrogel microsphere for selective and reversible detection of Hg{sup 2+}

    Energy Technology Data Exchange (ETDEWEB)

    Song, Zhenhu; Wang, Fang; Qiang, Jian; Zhang, Zhijie; Chen, Yahui; Wang, Yong; Zhang, Wei; Chen, Xiaoqiang

    2017-03-15

    We developed a simple and sensitive hydrogel sensor in the form of microspheres by using fluorescence probe encapsulated within a hydrogel matrix for the detection of Hg{sup 2+}. The traditional fluorescence probes suspended in solution are not transportable and recoverable. To overcome these disadvantages, we devised poly(ethylene glycol) diacrylate-based hydrogel microspheres in which fluorescence probe (R19S) was embedded at high density. The functionalized hydrogel microspheres were prepared by combining a microfluidic device with UV light. The hydrogel microspheres-based sensor exhibited good selectivity to Hg{sup 2+} among various metal ions and high sensitivity with a detection limit of 90 nM. Furthermore, after binding with Hg{sup 2+}, the R19S encapsulated hydrogel microspheres can be separated from testing samples easily and treated with the solution containing KI to remove Hg{sup 2+} and realize reusable detection. The current work may offer a new method for Hg{sup 2+} recognition with a more efficient manner.

  15. Same-day {sup 90}Y radioembolization: implementing a new treatment paradigm

    Energy Technology Data Exchange (ETDEWEB)

    Gabr, Ahmed; Kallini, Joseph Ralph; Gates, Vanessa L.; Hickey, Ryan; Desai, Kush; Thornburg, Bartley; Marshall, Karen; Salzig, Krystina; Williams, Melissa; Del Castillo, Carlene; Hohlastos, Elias; Lewandowski, Robert J. [Northwestern Memorial Hospital, Robert H. Lurie Comprehensive Cancer Center, Department of Radiology, Section of Interventional Radiology, Chicago, IL (United States); Kulik, Laura; Ganger, Daniel [Northwestern University, Department of Medicine, Division of Hepatology, Chicago, IL (United States); Baker, Talia [Northwestern University, Department of Surgery, Division of Transplantation, Comprehensive Transplant Center, Chicago, IL (United States); Salem, Riad [Northwestern Memorial Hospital, Robert H. Lurie Comprehensive Cancer Center, Department of Radiology, Section of Interventional Radiology, Chicago, IL (United States); Northwestern University, Department of Surgery, Division of Transplantation, Comprehensive Transplant Center, Chicago, IL (United States); Robert H. Lurie Comprehensive Cancer Center, Northwestern University, Department of Medicine, Division of Hematology and Oncology, Chicago, IL (United States)

    2016-12-15

    To assess the feasibility of conducting pretreatment mesenteric angiography, coil embolization, {sup 99m}Tc macroaggregated albumin ({sup 99m}Tc-MAA) scintigraphy, and {sup 90}Y radioembolization treatment in a single, same-day, combined outpatient encounter. This was a retrospective study of 78 patients treated during the period 2008 - 2015 who were managed in a single outpatient encounter under the guidance of the Interventional Radiology Department and The Nuclear Medicine Department. Pretreatment planning was performed by reviewing baseline imaging and estimated perfused liver volume bearing the tumor. The region of interest was estimated using 3-D software; this value was used for dosimetry planning. Maximum lung shunting fractions of 10 % for hepatocellular carcinoma and 5 % for liver metastases were assumed. Subsequently, hepatic angiography and {sup 99m}Tc-MAA scintigraphy were performed followed by {sup 90}Y treatment in one outpatient encounter. Total in-room procedure time was recorded. All patients underwent same-day angiography, {sup 99m}Tc-MAA scintigraphy and {sup 90}Y radioembolization. Of the 78 patients, 16 received multiple segmental treatments to both lobes, 44 received treatment to the right lobe, and 18 received treatment to the left lobe. The median dose was 106 Gy. The median number of {sup 90}Y vials needed was two (range one to six). The median in-room time was 160 min (75 - 250 min). The residential status of the patients was as follows, 18 % (14/78) were local residents, 55 % (43/78) traveled from outside the city limits, 18 % (14/78) were from out-of-state, and 9 % (7/78) were resident abroad. Of the 78 patients, 61 (77 %) had hepatocellular carcinoma, and 17 (22 %) had liver metastases. The median lung dose was 3.5 Gy. This study demonstrated the feasibility of same-day {sup 90}Y evaluation and treatment while maintaining the principles of safe and effective {sup 90}Y infusion including tumoricidal dosimetry (lobar, segmentectomy

  16. Comparison of positron emission tomography/CT and bremsstrahlung imaging following Y-90 radiation synovectomy

    International Nuclear Information System (INIS)

    Barber, Thomas W.; Yap, Kenneth S.K.; Cherk, Martin H.; Kalff, Victor; Powell, Anne

    2013-01-01

    The aim of this study is to compare the results of positron emission tomography (PET)/CT with bremsstrahlung imaging following Y-90 radiation synovectomy. All patients referred to our institution for Y-90 radiation synovectomy between July 2011 and February 2012 underwent both PET/CT and bremsstrahlung planar (±single photon emission computed tomography (SPECT) or SPECT/CT) imaging at 4 or 24 h following administration of Y-90 silicate colloid. PET image acquisition was performed for between 15 and 20min. In patients who underwent SPECT, side-by-side comparison with PET was performed and image quality/resolution scored using a five-point scale. The distribution pattern of Y-90 on PET and bremsstrahlung imaging was compared with the intra- or extra-articular location of Y-90 activity on fused PET/CT. Thirteen joints (11 knees and two ankles) were imaged with both PET/CT and planar bremsstrahlung imaging with 12 joints also imaged with bremsstrahlung SPECT. Of the 12 joints imaged with SPECT, PET image quality/resolution was superior in 11 and inferior in one. PET demonstrated a concordant distribution pattern compared with bremsstrahlung imaging in all scans, with the pattern classified as diffuse in 12 and predominantly focal in one. In all 12 diffuse scans, PET/CT confirmed the Y-90 activity to be located intra-articularly. In the one predominantly focal scan, the fused PET/CT images localised the Y-90 activity to mostly lie in the extra-articular space of the knee. PET/CT can provide superior image quality compared with bremsstrahlung imaging and may enable reliable detection of extra-articular Y-90 activity when there are focal patterns on planar bremsstrahlung imaging.

  17. The exploration of nursing care for patients with benign prostatic hyperplasia treated using 90Sr-90Y

    International Nuclear Information System (INIS)

    Xiao Lizhen; Bai Xuemei; Zhang Bihui; Yang Xiaoling

    2004-01-01

    An exploration of nursing care for patients with benign prostatic hyperplasia (BPH) treated using 90 Sr- 90 Y through the rectum was carried out . The treatment result and nursing experience in 90 cases were reported in this paper. Before the therapy nurses explained the method and principle of this treatment to the patients for the sake of increasing their confidence and to help them complete the treatment course successfully. During the radiotherapy, nurses practiced strictly radiation protection principles and operating instructions. They assisted the patients to have a healthy life style and good diet . The result of treatment indicated that the total effectiveness rate was 96.7%. The symptoms of lower urinary obstruction were improved evidently and the life quality of the patients elevated. Observation of clinical system confirmed that 90 Sr- 90 Y may be a new treatment method of BPH with benefits of safe irradiation dos, easy operation, non-traumatization, painlessness, and remarkable curative effects. However, it should be stressed that nursing care plays a pivotal role in the treatment result. (authors)

  18. Preparation and evaluation of microspheres of xyloglucan and its thiolated xyloglucan derivative.

    Science.gov (United States)

    Sonawane, Savita; Bhalekar, Mangesh; Shimpi, Shamkant

    2014-08-01

    Xyloglucan is a natural polymer reported to possess mucoadhesive properties. To enhance the mucoadhesion potential, xyloglucan was thiolated with cysteine. The microspheres of xyloglucan were prepared using a biocompatible crosslinker sodium trimetaphosphate and it was optimized for formulation variables, namely polymer concentration, internal:external phase ratio and stirring speed using a Box-Behnken experimental design. The formulation was also optimized for performance parameters like entrapment, t80 and % mucoadhesion. The microspheres were characterized by Fourier transform infrared spectroscopy, DSC and SEM for the optimum formula and then were reproduced by replacing the xyloglucan with thiomer. The microspheres formed showed entrapment efficiency of about 80%, t80 of about 400min and % mucoadhesion of 60% while same for thiomer were 90%, 500min and 80% respectively. In oral glucose tolerance test protocol the thiomer microspheres showed significant reduction in blood glucose levels. Thus thiolated xyloglucan offers a better polymer for multiparticulate drug delivery. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Evaluation of Effective Parameters on Labeling of Hydroxyapatite Compound with 90Y and Introducing the Best Method to Produce 90Y-HAp Radiopharmaceutical for Radio synovectomy

    International Nuclear Information System (INIS)

    Davarpanah, M. R.; Khoshhosn, H. A.; Attar Nosrati, S.; Harati, S. M.; Aghamiri, S. M.; Ghannadi Maragheh, M.

    2012-01-01

    Radio synovectomy is a local intra-articular injection of radionuclides in colloidal form for treatment of articular inflammatory in rheumatoid arthritis, hemophilia or orthopedic troubles. β-emitting radionuclides can be used for various joints based on radiation energy. 90 Y is a pure β-emitter with a half-life of 64.1 hours that is used for treatment of the knee joint. β-radiation of this radionuclide possesses maximum energy of 2.281 MeV (99.98%), mean pathway of 3.6 mm in the soft tissue and maximum 11 mm. In this project, hydroxyapatite (HAp) is applied as a colloid maker agent that interacts with 90 Y 3+ ions via ion-dipole bonds and produces 90 Y-HAp. The colloidal pharmaceutical is produced by adding an acidic solution of 90 YCl 3 to an HAp suspension in saline. Effective parameters within which the colloid is applied, such as the volume of diluent, HAp particle size and sonication effect were evaluated and tested. First, these determinative parameters were optimized in the simulated conditions and then examined in the active phase. Finally, the best procedure was determined for the production of the radiopharmaceutical. Radionuclide purity of the radiopharmaceutical according to the primary 90 YCl 3 solution was over 99.9%. Labeling yield and radiochemical purity were obtained over 99% using TLC method in saline solvent up to three days after production of radiopharmaceutical. Radiochemical purity of 90 Y-HAp colloid was also evaluated in human serum albumin solution for three days at room temperature. The amount of released activity was between 0.3 to 2%.

  20. Comparison of gas clearance and radioactive microspheres for pancreatic blood flow measurement

    International Nuclear Information System (INIS)

    DeMar, A.R.; Graham, L.S.; Lake, R.; Fink, A.S.

    1989-01-01

    Measurement of pancreatic blood flow (PBF) is technically demanding. Although radiolabeled microspheres are considered the gold standard for PBF assessment, they have practical limitations. In the current study, H 2 and xenon-133 gas clearance techniques were adapted to PBF measurement and compared to radiolabeled microsphere techniques. Simultaneous measurements of PBF were made using either hydrogen or xenon gas washout and radiolabeled microspheres. Measurements were made under basal, vasoconstricted (vasopressin 2U i.v. or nicotine 4 micrograms/kg/h) and stimulated (secretin 125 ng/kg/h or 2 U/kg i.v.) conditions (random order). Mean PBF was 26.9 +/- 5.3, 50.5 +/- 2.3 and 27.6 +/- 5.2 ml/min/100 g basally, 36.9 +/- 8.0, 90.1 +/- 18.9, and 81.7 +/- 14.5 ml/min/100 g in the stimulated state, and 24.2 +/- 7.8, 25.0 +/- 3.5, and 14.9 +/- 7.5 ml/min/100 g in the vasoconstricted state for hydrogen gas clearance, xenon gas clearance, and radiolabeled microspheres, respectively. The H 2 clearance technique resulted in tissue trauma, was complicated by frequent electrode displacement, and correlated poorly (r2 = 0.36, p greater than 0.05) with microsphere values. In contrast, xenon clearance measurement had no apparent effect on the pancreas and correlated well (r2 = 0.83, p less than 0.01) with microsphere data. We conclude that xenon clearance offers an attractive, validated alternative to radiolabeled microspheres for measuring pancreatic blood flow

  1. The relationship between the percentage of lung shunting on Tc-99m macroaggregated albumin (Tc-99m MAA scan and the grade of hepatocellular carcinoma vascularity

    Directory of Open Access Journals (Sweden)

    Rania Refaat

    2014-06-01

    Conclusion: Tc-99m MAA scan is fundamental prior to Y-90 microsphere SIRT as it minimizes the risk of post-radioembolization complications, hence, enhancing the safety of Y-90 microsphere subsequent administration. Moreover, the percentage of lung shunting varies considerably among patients with HCC relying on the grade of tumor vascularity.

  2. Radiochemical schemes of obtaining 89Sr and 90Y radionuclides

    International Nuclear Information System (INIS)

    Usarov, Z. O.

    2010-03-01

    Key words: strontium-89, yttrium-90, extraction and extraction-chromatographic purification of radionuclides, radiopharmaceuticals. Subjects of research: strontium-89 and yttrium-90 radionuclides and their chloride forms. Purpose of work is developing of radiochemical technologies on obtaining of 89 Sr and 90 Y on the WWR-SM reactor with high radionuclide purity. Methods of research: extraction and extraction-chromatographic methods of radionuclides separation, beta- and gamma-spectrometric methods of activity measuring. The results obtained and their novelty: Were determined the conformity to laws of Y and Sr distribution in two-phase systems TBP-HNO 3 , TBP-NH 4 NO 3 , TBP-HCI, HDEHP-NO 3 , HDEHP-NH 4 NO 3 and HDEHP-HCI. Were determined the conformity to laws of Y and Sr distribution in systems with craun ethers DB-18K-6 and DTBDB-18K-6 from water solutions of HNO 3 . Radiochemical technologies on obtaining of 89 Sr and 90 Y radionuclides including radiochemical process of yttrium target with using the systems TBP-HNO 3 and HDEHP/Teflone were developed. Practical value: the radiochemical technology of obtaining 89 Sr with high radionuclide purity was developed. The method of preparation a chloride compound of 89 SrCl 2 which is used as a drug form for preparation of 89 Sr- 'Metastron' was developed. The relatively simple method of on the way obtaining 90 Y in the reactor with high radionuclidic purity that is useful for follow using in medical practice was offered. Degree of embed and economic effectivity: the developed technologies have approbation in manufacturing conditions in Radiopreparat Enterprise of INP AS RU and were offered for receiving of domestic preparations against of import foreign analogues. The statement about using the invention by obtained patent is attached to dissertation. Field of application: the received results will be introduced in manufacture at Radiopreparat Enterprise of INP AS RU for receiving of domestic preparations

  3. Thermoluminescent dosimetry of beta radiations of 90 Sr/ 90 Y using amorphous ZrO2

    International Nuclear Information System (INIS)

    Rivera M, T.; Olvera T, L.; Azorin N, J.; Barrera R, M.; Soto E, A.M.

    2005-01-01

    In this work the results of studying the thermoluminescent properties (Tl) of the zirconium oxide in its amorphous state (ZrO 2 -a) before beta radiations of 90 Sr/ 90 Y are presented. The amorphous powders of the zirconium oxide were synthesized by means of the sol-gel technique. The sol-gel process using alkoxides like precursors, is an efficient method to prepare a matrix of zirconium oxide by hydrolysis - condensation of the precursor to form chains of Zr-H 3 and Zr-O 2 . One of the advantages of this technique is the obtention of gels at low temperatures with very high purity and homogeneity. The powders were characterized by means of thermal analysis and by X-ray diffraction. The powders of ZrO 2 -a, previously irradiated with beta particles of 90 Sr/ 90 Y, presented a thermoluminescent curve with two peaks at 150 and 257 C. The dissipation of the information of the one ZrO 2 -a was of 40% the first 2 hours remaining constant the information for the following 30 days. The reproducibility of the information was of ± 2.5% in standard deviation. The studied characteristics allow to propose to the amorphous zirconium oxide as thermoluminescent dosemeter for the detection of beta radiation. (Author)

  4. Comparative effects of inhaled relatively insoluble forms of 90Y, 144Ce, and 90Sr on canine peripheral lymphocyte function

    International Nuclear Information System (INIS)

    Benjamin, S.A.; Jones, R.K.; Snipes, M.B.; Lustgarten, C.S.

    1976-01-01

    Dogs that have inhaled relatively insoluble forms of either alpha- or beta-emitting radionuclides manifest a peripheral lymphopenia, the development and course of which depends on both total dose and dose rate. The remaining peripheral lymphocytes in dogs exposed to longer lived beta-emitting radionuclides showed a depressed function as measured by the ability to respond to plant mitogens in vitro. This experiment was designed to evaluate the effect of dose rate on peripheral lymphocyte function by exposing dogs to aerosols of radionuclides with varied effective half-lives in the lung: 90 Y (2.6 days), 144 Ce (170 days), and 90 Sr (650 days). Three groups of four adult beagle dogs each were exposed by inhalation to 90 Y, 144 Ce, or 90 Sr in fused-clay particles. Two controls were matched with each group. Initial lung burdens and initial dose rates to the lung were 520 to 610 μCi/kg of body weight and 2200 to 2600 rads/day in the 90 Y group, 33 to 60 μCi/kg and 200 to 350 rads/day in the 144 Ce group, and 25 to 32 μCi/kg and 130 to 170 rads/day in the 90 Sr group. Hematologic parameters and lymphocyte function as measured by the ability of lymphocytes to respond to plant mitogen stimulation were evaluated on a weekly or biweekly basis for 8 weeks after exposure and on a monthly basis thereafter. The 90 Y-exposed dogs showed a marked lymphopenia within 1 week with a return to control levels by 20 weeks after exposure. The remaining peripheral lymphocytes, however, showed no functional changes in these dogs. Animals exposed to 144 Ce or 90 Sr developed a progressive and persisent lymphopenia and showed functional depression of the remaining lymphocytes as well. The relationships among dose pattern, lymphopenia, and lymphocyte-function depression are discussed

  5. Thermoluminescent dosimetry of beta radiations of {sup 90} Sr/ {sup 90} Y using ZrO{sub 2}: Eu; Dosimetria termoluminiscente de radiaciones beta de {sup 90} Sr/ {sup 90} Y usando ZrO{sub 2}: Eu

    Energy Technology Data Exchange (ETDEWEB)

    Olvera T, L.; Azorin N, J.; Barrera S, M.; Soto E, A.M. [UAM-I, 09340 Mexico D.F. (Mexico); Rivera M, T. [CICATA-IPN, Legaria 694, 11500 Mexico D.F. (Mexico)

    2005-07-01

    In this work the results of studying the thermoluminescent properties (TL) of the doped zirconium oxide with europium (ZrO{sub 2}: Eu{sup 3+}) before beta radiations of {sup 90}Sr/ {sup 90}Y are presented. The powders of ZrO{sub 2}: Eu{sup 3+} were obtained by means of the sol-gel technique and they were characterized by means of thermal analysis and by X-ray diffraction. The powders of ZrO{sub 2}: Eu{sup 3+}, previously irradiated with beta particles of {sup 90}Sr/ {sup 90}Y, presented a thermoluminescent curve with two peaks at 204 and 292 C respectively. The TL response of the ZrO{sub 2}: Eu{sup 3+} as function of the absorbed dose was lineal from 2 Gy up to 90 Gy. The fading of the information of the ZrO{sub 2}: Eu{sup 3+} was of 10% the first 2 hours remaining almost constant the information by the following 30 days. The ZrO{sub 2} doped with the (Eu{sup 3+}) ion it was found more sensitive to the beta radiation that the one of zirconium oxide without doping (ZrO{sub 2}) obtained by the same method. Those studied characteristics allow to propose to the doped zirconium oxide with europium like thermoluminescent dosemeter for the detection of the beta radiation. (Author)

  6. Development of 90Y-DOTA-nimotuzumab Fab fragment for radioimmunotherapy

    International Nuclear Information System (INIS)

    Alonso Martinez, L.M.; Marylaine Perez-Malo Cruz; Rene Leyva Montana; Calzada Falcon, V.N.; Minely Zamora Barrabi; Alejandro Arbesu Valdivia; Ignacio Hernandez Gonzalez; Mariela Leon Perez

    2014-01-01

    Yttrium-90-( 90 Y) labeled monoclonal antibodies prepared with a chelating agent, 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA), have been used for radioimmunotherapy of cancer. In the present work, the Fab fragment of anti-EGFR monoclonal antibody nimotuzumab was prepared with high purity, integrity and biological activity. The Fab fragment with high specific recognition of EGFR in NCI-H125 human lung adenocarcinoma cells was derivatized with DOTA-NHS applying a simple procedure. DOTA-nimotuzumab Fab fragment was successfully radiolabeled with 90 Y with high radiochemical yield. The in vitro stability of labeled product was optimal over 24 h in buffered solution at 37 deg C. Biodistribution and pharmacokinetic studies correctly evaluated the in vivo non-tumor uptake, dosage regimen and excretion pathway in normal Wistar rats. (author)

  7. Treatment of hepatocellular carcinoma (HCC) with intra-arterial Yttrium-90 microspheres for down-staging patients to transplantation

    International Nuclear Information System (INIS)

    De Man, K.; Defreyne, L.; Delanghe, E.; Smeets, P.; Verhelst, X.; Geerts, A.; Van Vlierberghe, H.; Rogiers, X.; Troisi, R.; Lambert, B.

    2015-01-01

    Full text of publication follows. Introduction and aim: in our hospital, patients are referred for intra-arterial treatment with Yttrium-90 microspheres if they present with an HCC confined to the liver, but are ineligible for curative treatment options such as liver transplantation, partial hepatectomy or radio-frequent ablation. Additional eligibility criteria for radio-embolisation consist of Child-P ugh score 90 microspheres in our hospital since 2008 and who presented at an age <70 and with a disease load exceeding the Milan criteria (single tumour ≤5 cm or ≤ 3 lesions ≤ 3 cm). We recorded whether the patient was down staged to a tumour load complying with the Milan criteria, and if so, whether transplantation was carried out. Results: 40 patients aged <70 years and with a tumour load exceeding the Milan criteria (all treated with TheraSphere, Nordion except 1 with SIR-Spheres, Sirtex) were evaluable. 35 had Barcelona Clinic Liver Cancer (BCLC) B stage disease and 5 had BCLC C. Overall median survival was 12.9 months. 16 out of 40 patients were down staged to the Milan criteria (40%, all BCLC B), of whom 8 were actually transplanted so far. Two patients are on the waiting list, 1 patient refuses to be listed and 1 patient suffers co-morbidity that excludes him from abdominal surgery. Unfortunately 4 patients died before or during work-out for transplantation: 1 unexplained sudden death, 1 lung embolism and 2 due to liver failure. The overall median survival was 30,4 months in the down staged patients. 24 out 40 patients (60%) did not have a tumour load within the Milan criteria at any point of their follow up and had a significant worse

  8. Treatment of unresectable hepatocellular carcinoma with intrahepatic yttrium 90 microspheres: factors associated with liver toxicities.

    Science.gov (United States)

    Goin, James E; Salem, Riad; Carr, Brian I; Dancey, Janet E; Soulen, Michael C; Geschwind, Jean Francois H; Goin, Kathleen; Van Buskirk, Mark; Thurston, Kenneth

    2005-02-01

    Intraarterial injection of yttrium 90 microspheres (TheraSpheres) is used in the treatment of hepatocellular carcinoma (HCC). This article presents an analysis of the incidence of liver toxicities (liver-related events) and pretreatment factors associated with liver toxicities after TheraSphere treatment. Eighty-eight TheraSphere-treated patients with low 90-day mortality risk were selected for analysis, with liver toxicities coded with use of standard oncology criteria. Descriptive and inferential statistical methods were applied to estimate the incidence of liver toxicities and to evaluate the influence of liver radiation dose and various pretreatment factors on the risk of their occurrence. Sixty-eight liver toxicities occurred in 37 of the 88 patients (42%). Thirty-two patients (36%) experienced 50 liver toxicities after the first treatment and nine of 23 patients (39%) who received a second treatment experienced 18 liver toxicities. Pretreatment total bilirubin and liver radiation dose were found to be associated with the risk of at least one liver toxicity and with the time to first occurrence of a liver toxicity after first treatment. Pretreatment total bilirubin also was associated with liver toxicities after the second treatment. Most of the toxicities resolved; however, those that did not resolve were attributed to tumor progression or advancing cirrhosis. The risk of liver toxicities in patients with unresectable HCC treated with TheraSpheres increases with increasing pretreatment total bilirubin level and liver radiation dose to a maximum of 150 Gy for a single administration. The toxicities attributed to treatment resolved over time, and none of the patients studied had confirmed radiation-induced liver disease. Consequently, doses as high as 150 Gy on a single administration and as high as 268 Gy on repeated administrations were well tolerated.

  9. Mucoadhesive microspheres for gastroretentive delivery of acyclovir: in vitro and in vivo evaluation.

    Science.gov (United States)

    Dhaliwal, Sumeet; Jain, Subheet; Singh, Hardevinder P; Tiwary, A K

    2008-06-01

    The aim of the present investigation was to evaluate the potential use of mucoadhesive microspheres for gastroretentive delivery of acyclovir. Chitosan, thiolated chitosan, Carbopol 71G and Methocel K15M were used as mucoadhesive polymers. Microsphere formulations were prepared using emulsion-chemical crosslinking technique and evaluated in vitro, ex-vivo and in-vivo. Gelatin capsules containing drug powder showed complete dissolution (90.5 +/- 3.6%) in 1 h. The release of drug was prolonged to 12 h (78.8 +/- 3.9) when incorporated into mucoadhesive microspheres. The poor bioavailability of acyclovir is attributed to short retention of its dosage form at the absorption sites (in upper gastrointestinal tract to duodenum and jejunum). The results of mucoadhesion study showed better retention of thiolated chitosan microspheres (8.0 +/- 0.8 h) in duodenal and jejunum regions of intestine. The results of qualitative and quantitative GI distribution study also showed significant higher retention of mucoadhesive microspheres in upper GI tract. Pharmacokinetic study revealed that administration of mucoadhesive microspheres could maintain measurable plasma concentration of acyclovir through 24 h, as compared to 5 h after its administration in solution form. Thiolated chitosan microsphere showed superiority over the other formulations as observed with nearly 4.0-fold higher AUC(0-24) value (1,090 +/- 51 ng h/ml) in comparison to drug solution (281 +/- 28 ng h/ml). Overall, the result indicated prolonged delivery with significant improvement in oral bioavailability of acyclovir from mucoadhesive microspheres due to enhanced retention in the upper GI tract.

  10. Y-90 PET imaging for radiation theragnosis using bootstrap event re sampling

    International Nuclear Information System (INIS)

    Nam, Taewon; Woo, Sangkeun; Min, Gyungju; Kim, Jimin; Kang, Joohyun; Lim, Sangmoo; Kim, Kyeongmin

    2013-01-01

    Surgical resection is the most effective method to recover the liver function. However, Yttrium-90 (Y-90) has been used as a new treatment due to the fact that it can be delivered to the tumors and results in greater radiation exposure to the tumors than using external radiation nowadays since most treatment is palliative in case of unresectable stage of hepatocellular carcinoma (HCC). Recently, Y-90 has been received much interest and studied by many researchers. Imaging of Y-90 has been conducted using most commonly gamma camera but PET imaging is required due to low sensitivity and resolution. The purpose of this study was to assess statistical characteristics and to improve count rate of image for enhancing image quality by using nonparametric bootstrap method. PET data was able to be improved using non-parametric bootstrap method and it was verified with showing improved uniformity and SNR. Uniformity showed more improvement under the condition of low count rate, i.e. Y-90, in case of phantom and also uniformity and SNR showed improvement of 15.6% and 33.8% in case of mouse, respectively. Bootstrap method performed in this study for PET data increased count rate of PET image and consequentially time for acquisition time can be reduced. It will be expected to improve performance for diagnosis

  11. Country report: India. Development of Radiopharmaceuticals Based on {sup 188}Re and {sup 90}Y for Radionuclide Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Venkatesh, M.; Pandey, U.; Dhami, P. S.; Chakravarty, R.; Kameswaran, M.; Subramanian, S.; Dash, A.; Samuel, G. [Bhabha Atomic Research Centre, Trombay, Mumbai 400 085 (India)

    2010-07-01

    During the past decade, our group has focused attention on the development of therapeutic radiopharmaceuticals incorporating radioisotopes such as {sup 90}Y, {sup 188}Re etc. As the primary source of the radioisotopes {sup 90}Y and {sup 188}Re are the {sup 90}Sr/{sup 90}Y generators and {sup 188}W/{sup 188}Re generators respectively, the local availability of these generator systems is very important for the successful development of radiopharmaceuticals incorporating these radioisotopes. In this context, {sup 90}Sr/{sup 90}Y generators based on Supported Liquid Membrane (SLM) [1-3] and electrochemical techniques [4] could be designed and deployed in our laboratories for the elution of {sup 90}Y to be used for preparation of {sup 90}Y labeled products. This work formed a part of the IAEA co-ordinated CRP on “Development of Generator Technologies for Therapeutic Radionuclides: {sup 90}Y and {sup 188}Re”. In this report, work on the development of {sup 90}Y radiopharmaceuticals for treatment of liver cancer and non-Hodgkin’s lymphoma (NHL) is reported. In addition, comparison of the Extraction Paper Chromatography technique (EPC) developed for determination of {sup 90}Sr contamination in {sup 90}Y samples with the US Pharmacopeia recommended method as well as the validation of the EPC technique is presented.

  12. [Optimization of calcium alginate floating microspheres loading aspirin by artificial neural networks and response surface methodology].

    Science.gov (United States)

    Zhang, An-yang; Fan, Tian-yuan

    2010-04-18

    To investigate the preparation and optimization of calcium alginate floating microspheres loading aspirin. A model was used to predict the in vitro release of aspirin and optimize the formulation by artificial neural networks (ANNs) and response surface methodology (RSM). The amounts of the material in the formulation were used as inputs, while the release and floating rate of the microspheres were used as outputs. The performances of ANNs and RSM were compared. ANNs were more accurate in prediction. There was no significant difference between ANNs and RSM in optimization. Approximately 90% of the optimized microspheres could float on the artificial gastric juice over 4 hours. 42.12% of aspirin was released in 60 min, 60.97% in 120 min and 78.56% in 240 min. The release of the drug from the microspheres complied with Higuchi equation. The aspirin floating microspheres with satisfying in vitro release were prepared successfully by the methods of ANNs and RSM.

  13. Prolonged amelioration of experimental postoperative pain by bupivacaine released from microsphere-coated hernia mesh.

    Science.gov (United States)

    Ohri, Rachit; Wang, Jeffery Chi-Fei; Pham, Lan; Blaskovich, Phillip D; Costa, Daniel; Nichols, Gary; Hildebrand, William; Scarborough, Nelson; Herman, Clifford; Strichartz, Gary R

    2014-01-01

    Postoperative pain alters physiological functions and delays discharge. Perioperative local anesthetics are effective analgesics in the immediate 1- to 2-day postoperative period, but acute pain often lasts longer. The goal of this work was to develop a local anesthetic formulation adhering to an intraoperative implanted device that reduces pain for at least 3 days after surgery. Six groups, each with 8 rats, were studied. In a control group (group I), one 1.2-cm-long incision of the skin was followed by blunt dissection to separate the skin away from the underlying tissues and closing with 2 sutures. In 3 of the treatment groups, the same surgical procedure was used, with the subcutaneous space formed by the blunt dissection lined with a 1-cm square patch of hernia mesh coated with poly lactide co-glycolic acid microspheres containing approximately 17 mg of bupivacaine (group II), no drug (placebo; group III), or bupivacaine free-base powder (group IV). Uncoated mesh implants (group V) served as a secondary control. A standard bupivacaine solution (0.4 mL, 0.5%; 2-mg dose) was infiltrated subcutaneously 30 minutes before the surgery and served as a standard control (group VI). Mechanosensitivity of the skin was tested by the local subcutaneous muscle responses to cutaneous tactile stimulation by von Frey hairs with forces of 4 g (for allodynia) and 15 g (for hyperalgesia) preoperatively and for 7 postoperative days. Control rats (group I) showed mechanohypersensitivity, indicative of postoperative allodynia and hyperalgesia, for all 7 postoperative days. Mechanohyperalgesia in rats that received mesh coated with bupivacaine-releasing microspheres (group II) was reduced during this period to 13% of control postoperative values (P < 0.001); mesh coated with bupivacaine base (group IV) reduced it by 50% (P = 0.034). The placebo mesh (group III) and uncoated mesh (group V) caused no significant reduction of mechanohypersensitivity, and bupivacaine solution infiltrated

  14. Metallic coating of microspheres

    International Nuclear Information System (INIS)

    Meyer, S.F.

    1980-01-01

    Extremely smooth, uniform metal coatings of micrometer thicknesses on microscopic glass spheres (microspheres) are often needed as targets for inertial confinement fusion (ICF) experiments. The first part of this paper reviews those methods used successfully to provide metal coated microspheres for ICF targets, including magnetron sputtering, electro- and electroless plating, and chemical vapor pyrolysis. The second part of this paper discusses some of the critical aspects of magnetron sputter coating of microspheres, including substrate requirements, the sticking of microspheres during coating (preventing a uniform coating), and the difficulties in growing the desired dense, smooth, uniform microstructure on continuously moving spherical substrates

  15. The solvent extraction of carrier-free 90Y from 90Sr with crown ethers

    International Nuclear Information System (INIS)

    Chuang, J.T.; Lo, J.G.

    1995-01-01

    A simple solvent extraction method has been developed for the separation of 90 Y from 90 Sr. Crown ether dissolved in chloroform was used as a selective reagent and organic picrate anion was chosen as a counter ion. The effect of various factors on the extraction equilibrium constant of strontium log K ex = 9.15 was obtained from the study of the distribution coefficient versus to crown ether concentration. The separation method was simple, resulted high purity (>99.9%) and quantitative yield, and took less than half an hour. (author) 27 refs.; 4 figs.; 4 tabs

  16. Root Cause Analysis of Gastroduodenal Ulceration After Yttrium-90 Radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Lam, Marnix G. E. H. [Stanford University School of Medicine, Division of Interventional Radiology (United States); Banerjee, Subhas [Stanford University School of Medicine, Division of Gastroenterology and Hepatology (United States); Louie, John D.; Abdelmaksoud, Mohamed H. K. [Stanford University School of Medicine, Division of Interventional Radiology (United States); Iagaru, Andrei H. [Stanford University School of Medicine, Division of Nuclear Medicine and Molecular Imaging (United States); Ennen, Rebecca E.; Sze, Daniel Y., E-mail: dansze@stanford.edu [Stanford University School of Medicine, Division of Interventional Radiology (United States)

    2013-12-15

    IntroductionA root cause analysis was performed on the occurrence of gastroduodenal ulceration after hepatic radioembolization (RE). We aimed to identify the risk factors in the treated population and to determine the specific mechanism of nontarget RE in individual cases. Methods: The records of 247 consecutive patients treated with yttrium-90 RE for primary (n = 90) or metastatic (n = 157) liver cancer using either resin (n = 181) or glass (n = 66) microspheres were reviewed. All patients who developed a biopsy-proven microsphere-induced gastroduodenal ulcer were identified. Univariate and multivariate analyses were performed on baseline parameters and procedural data to determine possible risk factors in the total population. Individual cases were analyzed to ascertain the specific cause, including identification of the culprit vessel(s) leading to extrahepatic deposition of the microspheres. Results: Eight patients (3.2 %) developed a gastroduodenal ulcer. Stasis during injection was the strongest independent risk factor (p = 0.004), followed by distal origin of the gastroduodenal artery (p = 0.004), young age (p = 0.040), and proximal injection of the microspheres (p = 0.043). Prolonged administrations, pain during administration, whole liver treatment, and use of resin microspheres also showed interrelated trends in multivariate analysis. Retrospective review of intraprocedural and postprocedural imaging showed a probable or possible culprit vessel, each a tiny complex collateral vessel, in seven patients. Conclusion: Proximal administrations and those resulting in stasis of flow presented increased risk for gastroduodenal ulceration. Patients who had undergone bevacizumab therapy were at high risk for developing stasis.

  17. Root Cause Analysis of Gastroduodenal Ulceration After Yttrium-90 Radioembolization

    International Nuclear Information System (INIS)

    Lam, Marnix G. E. H.; Banerjee, Subhas; Louie, John D.; Abdelmaksoud, Mohamed H. K.; Iagaru, Andrei H.; Ennen, Rebecca E.; Sze, Daniel Y.

    2013-01-01

    IntroductionA root cause analysis was performed on the occurrence of gastroduodenal ulceration after hepatic radioembolization (RE). We aimed to identify the risk factors in the treated population and to determine the specific mechanism of nontarget RE in individual cases. Methods: The records of 247 consecutive patients treated with yttrium-90 RE for primary (n = 90) or metastatic (n = 157) liver cancer using either resin (n = 181) or glass (n = 66) microspheres were reviewed. All patients who developed a biopsy-proven microsphere-induced gastroduodenal ulcer were identified. Univariate and multivariate analyses were performed on baseline parameters and procedural data to determine possible risk factors in the total population. Individual cases were analyzed to ascertain the specific cause, including identification of the culprit vessel(s) leading to extrahepatic deposition of the microspheres. Results: Eight patients (3.2 %) developed a gastroduodenal ulcer. Stasis during injection was the strongest independent risk factor (p = 0.004), followed by distal origin of the gastroduodenal artery (p = 0.004), young age (p = 0.040), and proximal injection of the microspheres (p = 0.043). Prolonged administrations, pain during administration, whole liver treatment, and use of resin microspheres also showed interrelated trends in multivariate analysis. Retrospective review of intraprocedural and postprocedural imaging showed a probable or possible culprit vessel, each a tiny complex collateral vessel, in seven patients. Conclusion: Proximal administrations and those resulting in stasis of flow presented increased risk for gastroduodenal ulceration. Patients who had undergone bevacizumab therapy were at high risk for developing stasis

  18. Dose distribution following selective internal radiation therapy

    International Nuclear Information System (INIS)

    Fox, R.A.; Klemp, P.F.; Egan, G.; Mina, L.L.; Burton, M.A.; Gray, B.N.

    1991-01-01

    Selective Internal Radiation Therapy is the intrahepatic arterial injection of microspheres labelled with 90Y. The microspheres lodge in the precapillary circulation of tumor resulting in internal radiation therapy. The activity of the 90Y injected is managed by successive administrations of labelled microspheres and after each injection probing the liver with a calibrated beta probe to assess the dose to the superficial layers of normal tissue. Predicted doses of 75 Gy have been delivered without subsequent evidence of radiation damage to normal cells. This contrasts with the complications resulting from doses in excess of 30 Gy delivered from external beam radiotherapy. Detailed analysis of microsphere distribution in a cubic centimeter of normal liver and the calculation of dose to a 3-dimensional fine grid has shown that the radiation distribution created by the finite size and distribution of the microspheres results in an highly heterogeneous dose pattern. It has been shown that a third of normal liver will receive less than 33.7% of the dose predicted by assuming an homogeneous distribution of 90Y

  19. Hierarchical Mn₂O₃ Microspheres In-Situ Coated with Carbon for Supercapacitors with Highly Enhanced Performances.

    Science.gov (United States)

    Gong, Feilong; Lu, Shuang; Peng, Lifang; Zhou, Jing; Kong, Jinming; Jia, Dianzeng; Li, Feng

    2017-11-23

    Porous Mn₂O₃ microspheres have been synthesized and in-situ coated with amorphous carbon to form hierarchical C@Mn₂O₃ microspheres by first producing MnCO₃ microspheres in solvothermal reactions, and then annealing at 500 °C. The self-assembly growth of MnCO₃ microspheres can generate hollow structures inside each of the particles, which can act as micro-reservoirs to store biomass-glycerol for generating amorphous carbon onto the surfaces of Mn₂O₃ nanorods consisting of microspheres. The C@Mn₂O₃ microspheres, prepared at 500 °C, exhibit highly enhanced pseudocapacitive performances when compared to the particles after annealed at 400 °C and 600 °C. Specifically, the C@Mn₂O₃ microspheres prepared at 500 °C show high specific capacitances of 383.87 F g -1 at current density of 0.5 A g -1 , and excellent cycling stability of 90.47% of its initial value after cycling for 5000 times. The asymmetric supercapacitors assembled with C@Mn₂O₃ microspheres after annealed at 500 °C and activated carbon (AC) show an energy density of up to 77.8 Wh kg -1 at power density of 500.00 W kg -1 , and a maximum power density of 20.14 kW kg -1 at energy density of 46.8 Wh kg -1 . We can attribute the enhanced electrochemical performances of the materials to their three-dimensional (3D) hierarchical structure in-situ coated with carbon.

  20. Hepatic vein tumor thrombus as a risk factor for excessive pulmonary deposition of microspheres during TheraSphere therapy for unresectable hepatocellular carcinoma.

    Science.gov (United States)

    Fleming, Chad J; Andrews, James C; Wiseman, Gregory A; Gansen, Denise N; Roberts, Lewis R

    2009-11-01

    To evaluate the impact of identifiable hepatic vein tumor thrombus on the ability to safely deliver TheraSphere (yttrium 90-containing glass microspheres) for the treatment of hepatocellular carcinoma (HCC). A retrospective review was performed of 87 patients (71 men, 16 women; mean age, 64.5 years; age range, 25-83 y) referred for TheraSphere therapy for HCC during a 2-year period between April 2005 and May 2007. Evaluation included contrast-enhanced computed tomography or magnetic resonance imaging, selective mesenteric angiography, and radionuclide perfusion scintigraphy to measure the arteriovenous shunting through the tumor. Of the 87 patients, 83 underwent angiography and perfusion scintigraphy; 53 were ultimately treated with 65 glass microsphere infusions. Twelve of 83 were identified as having tumor thrombus in a hepatic vein or extending into the inferior vena cava. The mean lung shunt for the patients with hepatic vein tumor thrombus was 30% (range, 11%-60%), compared with 8.2% (range, 3%-23%) for patients without identifiable tumor thrombus. Two of the 12 patients were treated with reduced doses of glass microspheres, and the remaining 10 were offered alternative therapies. The presence of hepatic vein tumor thrombus is a risk factor for an increased lung shunt that may prohibit delivery of a therapeutic dose of TheraSphere to hepatic tumor.

  1. Biocompatibility Research of a Novel pH Sensitive Ion Exchange Resin Microsphere.

    Science.gov (United States)

    Liu, Hongfei; Shi, Shuangshuang; Pan, Weisan; Sun, Changshan; Zou, Xiaomian; Fu, Min; Feng, Yingshu; Ding, Hui

    2014-01-01

    The main objective of this study was to investigate biocompatibility and provide in-vivo pharmacological and toxicological evidence for further investigation of the possibility of pH sensitive ion exchange resin microsphere for clinical utilizations. Acute toxicity study and general pharmacological studies were conducted on the pH sensitive ion exchange resin microsphere we prepared. The general pharmacological studies consist of the effects of the pH sensitive ion exchange resin microsphere on the nervous system of mice, the functional coordination of mice, the hypnosis of mice treated with nembutal at subliminal dose, the autonomic activities of tested mice, and the heart rate, blood pressure, ECG and breathing of the anesthetic cats. The LD50 of pH sensitive ion exchange resin microsphere after oral administration was more than 18.84 g·Kg(-1). Mice were orally administered with 16 mg·Kg(-1), 32 mg·Kg(-1) and 64 mg·Kg(-1) of pH sensitive ion exchange resin microsphere and there was no significant influence on mice nervous system, general behavior, function coordination, hypnotic effect treated with nembutal at subliminal dose and frequency of autonomic activities. Within the 90 min after 5 mg·Kg(-1), 10 mg·Kg(-1), 20 mg·Kg(-1) pH sensitive ion exchange resin microsphere was injected to cat duodenum, the heart rate, blood pressure, breathing and ECG of the cats didn't make significant changes in each experimental group compared with the control group. The desirable pharmacological and toxicological behaviors of the pH sensitive ion exchange resin microsphere exhibited that it has safe biocompatibility and is possible for clinical use.

  2. Thermoluminescent dosimetry of beta radiations of {sup 90} Sr/ {sup 90} Y using amorphous ZrO{sub 2}; Dosimetria termoluminiscente de radiaciones beta de {sup 90} Sr/ {sup 90} Y usando ZrO{sub 2} amorfo

    Energy Technology Data Exchange (ETDEWEB)

    Rivera M, T. [CICATA-Legaria, IPN, Legaria Num. 694, 11500 Mexico D.F. (Mexico); Olvera T, L.; Azorin N, J.; Barrera R, M.; Soto E, A.M. [UAM-I, 09340 Mexico D.F. (Mexico)

    2005-07-01

    In this work the results of studying the thermoluminescent properties (Tl) of the zirconium oxide in its amorphous state (ZrO{sub 2}-a) before beta radiations of {sup 90} Sr/ {sup 90} Y are presented. The amorphous powders of the zirconium oxide were synthesized by means of the sol-gel technique. The sol-gel process using alkoxides like precursors, is an efficient method to prepare a matrix of zirconium oxide by hydrolysis - condensation of the precursor to form chains of Zr-H{sub 3} and Zr-O{sub 2}. One of the advantages of this technique is the obtention of gels at low temperatures with very high purity and homogeneity. The powders were characterized by means of thermal analysis and by X-ray diffraction. The powders of ZrO{sub 2}-a, previously irradiated with beta particles of {sup 90} Sr/{sup 90} Y, presented a thermoluminescent curve with two peaks at 150 and 257 C. The dissipation of the information of the one ZrO{sub 2}-a was of 40% the first 2 hours remaining constant the information for the following 30 days. The reproducibility of the information was of {+-} 2.5% in standard deviation. The studied characteristics allow to propose to the amorphous zirconium oxide as thermoluminescent dosemeter for the detection of beta radiation. (Author)

  3. Partition Model-Based 99mTc-MAA SPECT/CT Predictive Dosimetry Compared with 90Y TOF PET/CT Posttreatment Dosimetry in Radioembolization of Hepatocellular Carcinoma: A Quantitative Agreement Comparison.

    Science.gov (United States)

    Gnesin, Silvano; Canetti, Laurent; Adib, Salim; Cherbuin, Nicolas; Silva Monteiro, Marina; Bize, Pierre; Denys, Alban; Prior, John O; Baechler, Sebastien; Boubaker, Ariane

    2016-11-01

    90 Y-microsphere selective internal radiation therapy (SIRT) is a valuable treatment in unresectable hepatocellular carcinoma (HCC). Partition-model predictive dosimetry relies on differential tumor-to-nontumor perfusion evaluated on pretreatment 99m Tc-macroaggregated albumin (MAA) SPECT/CT. The aim of this study was to evaluate agreement between the predictive dosimetry of 99m Tc-MAA SPECT/CT and posttreatment dosimetry based on 90 Y time-of-flight (TOF) PET/CT. We compared the 99m Tc-MAA SPECT/CT results for 27 treatment sessions (25 HCC patients, 41 tumors) with 90 Y SIRT (7 glass spheres, 20 resin spheres) and the posttreatment 90 Y TOF PET/CT results. Three-dimensional voxelized dose maps were computed from the 99m Tc-MAA SPECT/CT and 90 Y TOF PET/CT data. Mean absorbed dose ([Formula: see text]) was evaluated to compute the predicted-to-actual dose ratio ([Formula: see text]) in tumor volumes (TVs) and nontumor volumes (NTVs) for glass and resin spheres. The Lin concordance ([Formula: see text]) was used to measure accuracy ([Formula: see text]) and precision (ρ). Administered activity ranged from 0.8 to 1.9 GBq for glass spheres and from 0.6 to 3.4 GBq for resin spheres, and the respective TVs ranged from 2 to 125 mL and from 6 to 1,828 mL. The mean dose [Formula: see text] was 240 Gy for glass and 122 Gy for resin in TVs and 72 Gy for glass and 47 Gy for resin in NTVs. [Formula: see text] was 1.46 ± 0.58 (0.65-2.53) for glass and 1.16 ± 0.41 (0.54-2.54) for resin, and the respective values for [Formula: see text] were 0.88 ± 0.15 (0.56-1.00) and 0.86 ± 0.2 (0.58-1.35). DR variability was substantially lower in NTVs than in TVs. The Lin concordance between [Formula: see text] and [Formula: see text] (resin) was significantly better for tumors larger than 150 mL than for tumors 150 mL or smaller ([Formula: see text] = 0.93 and [Formula: see text] = 0.95 vs. [Formula: see text] = 0.57 and [Formula: see text] = 0.93; P < 0.05). In 90 Y radioembolization

  4. In vitro evaluation and intra-articular administration of biodegradable microspheres containing naproxen sodium.

    Science.gov (United States)

    Bozdağ, S; Caliş, S; Kaş, H S; Ercan, M T; Peksoy, I; Hincal, A A

    2001-01-01

    The dispersion of non-steroidal antiinflammatory drugs (NSAIDs) into biodegradable polymeric matrices have been accepted as a good approach for obtaining a therapeutic effect in a predetermined period of time meanwhile minimizing the side effects of NSAIDs. In the present study, it was aimed to prepare Naproxen Sodium (NS), (a NSAID) loaded microsphere formulation using natural Bovine Serum Albumin (BSA) and synthetic biodegradable polymers such as poly(lactide-co-glycolic acid) (PLGA) (50:50 MW 34,000 and 88,000 Da) for intra-articular administration, and to study the retention of the drug at the site of injection in the knee joint. NS incorporated microspheres were evaluated in vitro for particle size (the mean particle size; for BSA microspheres, 10.0 +/- 0.3 microm, for PLGA microspheres, 9.0 +/- 0.2 and 5.0 +/- 0.1 microm for MW 34,000 and 88,000 Da, respectively), yield value, drug loading, surface morphology and drug release. For in vivo studies, monoarticular arthritis was induced in the left knee joints of rabbits by using ovalbumin and Freund's Complete Adjuvant as antigen and adjuvant. A certain time (4 days) is allowed for the formation of arthritis in the knee joints, then the NS loaded microspheres were injected directly into the articular cavity. At specific time points, gamma scintigrams were obtained to determine the residence time of the microspheres in knee joints, in order to determine the most suitable formulation. This study indicated that PLGA, a synthetic polymer, is more promising than the natural type BSA microspheres for an effective cure of mono-articular arthritis in rabbits.

  5. Depth dose distribution in the water for clinical applicators of 90Sr + 90Y, with a extrapolation mini chamber

    International Nuclear Information System (INIS)

    Antonio, Patricia de Lara; Caldas, Linda V.E.; Oliveira, Mercia L.

    2009-01-01

    This work determines the depth dose in the water for clinical applicators of 90 Sr + 90 Y, using a extrapolation mini chamber developed at the IPEN, Sao Paulo, Brazil, and different thickness acrylic plates. The obtained results were compared with the international recommendations and were considered satisfactory

  6. Biocompatibility, Inflammatory Response, and Recannalization Characteristics of Nonradioactive Resin Microspheres: Histological Findings

    International Nuclear Information System (INIS)

    Bilbao, Jose I.; Martino, Alba de; Luis, Esther de; Diaz-Dorronsoro, Lourdes; Alonso-Burgos, Alberto; Martinez de la Cuesta, Antonio; Sangro, Bruno; Garcia de Jalon, Jose A.

    2009-01-01

    Intra-arterial radiotherapy with yttrium-90 microspheres (radioembolization) is a therapeutic procedure exclusively applied to the liver that allows the direct delivery of high-dose radiation to liver tumors, by means of endovascular catheters, selectively placed within the tumor vasculature. The aim of the study was to describe the distribution of spheres within the precapillaries, inflammatory response, and recannalization characteristics after embolization with nonradioactive resin microspheres in the kidney and liver. We performed a partial embolization of the liver and kidney vessels in nine white pigs. The left renal and left hepatic arteries were catheterized and filled with nonradioactive resin microspheres. Embolization was defined as the initiation of near-stasis of blood flow, rather than total occlusion of the vessels. The hepatic circulation was not isolated so that the effects of reflux of microspheres into stomach could be observed. Animals were sacrificed at 48 h, 4 weeks, and 8 weeks, and tissue samples from the kidney, liver, lung, and stomach evaluated. Microscopic evaluation revealed clusters of 10-30 microspheres (15-30 μm in diameter) in the small vessels of the kidney (the arciform arteries, vasa recti, and glomerular afferent vessels) and liver. Aggregates were associated with focal ischemia and mild vascular wall damage. Occlusion of the small vessels was associated with a mild perivascular inflammatory reaction. After filling of the left hepatic artery with microspheres, there was some evidence of arteriovenous shunting into the lungs, and one case of cholecystitis and one case of marked gastritis and ulceration at the site of arterial occlusion due to the presence of clusters of microspheres. Beyond 48 h, microspheres were progressively integrated into the vascular wall by phagocytosis and the lumen recannalized. Eight-week evaluation found that the perivascular inflammatory reaction was mild. Liver cell damage, bile duct injury, and

  7. Failure mode and effects analysis in a dual-product microsphere brachytherapy environment.

    Science.gov (United States)

    Younge, Kelly Cooper; Lee, Choonik; Moran, Jean M; Feng, Mary; Novelli, Paula; Prisciandaro, Joann I

    We performed a failure mode and effects analysis (FMEA) during the addition of a new microspheres product into our existing microsphere brachytherapy program to identify areas for safety improvements. A diverse group of team members from the microsphere program participated in the project to create a process map, identify and score failure modes, and discuss programmatic changes to address the highest ranking items. We developed custom severity ranking scales for staff- and institution-related failure modes to encompass possible risks that may exist outside of patient-based effects. Between both types of microsphere products, 173 failure mode/effect pairs were identified: 90 for patients, 35 for staff, and 48 for the institution. The SIR-Spheres program was ranked separately from the TheraSphere program because of significant differences in workflow during dose calculation, preparation, and delivery. High-ranking failure modes in each category were addressed with programmatic changes. The FMEA aided in identifying potential risk factors in our microsphere program and allowed a theoretically safer and more efficient design of the workflow and quality assurance for both our new SIR-Spheres program and our existing TheraSphere program. As new guidelines are made available, and our experience with the SIR-Spheres program increases, we will update the FMEA as an efficient starting point for future improvements. Copyright © 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  8. Chitosan Microspheres as Radiolabeled Delivery Devices

    International Nuclear Information System (INIS)

    Permtermsin, Chalermsin; Ngamprayad, Tippanan; Phumkhem, Sudkanung; Srinuttrakul, Wannee; Kewsuwan, Prartana

    2007-08-01

    Full text: This study optimized conditions for preparing, characterizing, radiolabeled of chitosan microspheres and the biodistribution of 99mTc-Chitosan microspheres after intravenous administration. Particle size distribution of the microspheres was determined by light scattering. Zeta potential was studied by dynamic light scattering and electrophoresis technique. Biodistribution studies were performed by radiolabeling using 99mTc. The results shown that geometric mean diameter of the microspheres was found to be 77.26?1.96 ?m. Microsphere surface charge of chitosan microspheres was positive charge and zeta potential was 25.80 ? 0.46 mV. The labeling efficiency for this condition was more than 95% and under this condition was stable for at least 6 h. Radioactivity

  9. Synthesis of magnetic polymeric microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Gervald, A Yu; Gritskova, Inessa A; Prokopov, Nikolai I [M.V. Lomonosov Moscow State Academy of Fine Chemical Technology, Moscow (Russian Federation)

    2010-05-13

    The key types of magnetic polymeric microspheres are considered. Methods of synthesis of different types of magnetic nanoparticles and of preparation of stable magnetic fluids on their basis are outlined. The overview of the methods for the manufacture of magnetic polymeric microspheres is presented. The effect of the synthesis conditions on the characteristics of magnetic polymeric microspheres such as the diameter and the particle size distribution and the content of magnetic material is discussed by particular examples. The application fields of magnetic polymeric microspheres are briefly surveyed.

  10. Synthesis of magnetic polymeric microspheres

    International Nuclear Information System (INIS)

    Gervald, A Yu; Gritskova, Inessa A; Prokopov, Nikolai I

    2010-01-01

    The key types of magnetic polymeric microspheres are considered. Methods of synthesis of different types of magnetic nanoparticles and of preparation of stable magnetic fluids on their basis are outlined. The overview of the methods for the manufacture of magnetic polymeric microspheres is presented. The effect of the synthesis conditions on the characteristics of magnetic polymeric microspheres such as the diameter and the particle size distribution and the content of magnetic material is discussed by particular examples. The application fields of magnetic polymeric microspheres are briefly surveyed.

  11. Ceramic microspheres for cementing applications

    NARCIS (Netherlands)

    2011-01-01

    A method and apparatus for manufacturing ceramic microspheres from industrial slag. The microspheres have a particle size of about 38 microns to about 150 microns. The microspheres are used to create a cement slurry having a density of at least about 11 lbs/g. The resultant cement slurry may then be

  12. Ceramic microspheres for cementing applications

    NARCIS (Netherlands)

    2010-01-01

    A method and apparatus for manufacturing ceramic microspheres from industrial slag. The microspheres have a particle size of about 38 microns to about 150 microns. The microspheres are used to create a cement slurry having a density of at least about 11 lbs/g. The resultant cement slurry may then be

  13. Ceramic microspheres for cementing applications

    NARCIS (Netherlands)

    2012-01-01

    A method and apparatus for manufacturing ceramic microspheres from industrial slag. The microspheres have a particle size of about 38 microns to about 150 microns. The microspheres are used to create a cement slurry having a density of at least about 11 lbs/g. The resultant cement slurry may then be

  14. Treatment of advanced pancreatic carcinoma with 90Y-Clivatuzumab Tetraxetan: a phase I single-dose escalation trial.

    Science.gov (United States)

    Gulec, Seza A; Cohen, Steven J; Pennington, Kenneth L; Zuckier, Lionel S; Hauke, Ralph J; Horne, Heather; Wegener, William A; Teoh, Nick; Gold, David V; Sharkey, Robert M; Goldenberg, David M

    2011-06-15

    Humanized antibody hPAM4 specifically binds a mucin glycoprotein expressed in pancreatic adenocarcinomas. This phase I study evaluated a single dose of (90)Y-clivatuzumab tetraxetan ((90)Y-labeled hPAM4) in patients with advanced pancreatic cancer. Twenty-one patients (4 stage III; 17 stage IV) received (111)In-hPAM4 for imaging and serum sampling before (90)Y-hPAM4. Study procedures evaluated adverse events, safety laboratories, computed tomography (CT) scans, biomarkers, pharmacokinetics, radiation dosimetry, and immunogenicity (HAHA). (111)In-hPAM4 showed normal biodistribution with radiation dose estimates to red marrow and solid organs acceptable for radioimmunotherapy and with tumor targeting in 12 patients. One patient withdrew before (90)Y-hPAM4; otherwise, 20 patients received (90)Y doses of 15 (n = 7), 20 (n = 9), and 25 mCi/m(2) (n = 4). Treatment was well tolerated; the only significant drug-related toxicities were (NCI CTC v.3) grade 3 to 4 neutropenia and thrombocytopenia increasing with (90)Y dose. There were no bleeding events or serious infections, and most cytopenias recovered to grade 1 within 12 weeks. Three patients at 25 mCi/m(2) encountered dose-limiting toxicity with grade 4 cytopenias more than 7 days, establishing 20 mCi/m(2) as the maximal tolerated (90)Y dose. Two patients developed HAHA of uncertain clinical significance. Most patients progressed rapidly and with CA19-9 levels increasing within 1 month of therapy, but 7 remained progression-free by CT for 1.5 to 5.6 months, including 3 achieving transient partial responses (32%-52% tumor diameter shrinkage). (90)Y-Clivatuzumab tetraxetan was well tolerated with manageable hematologic toxicity at the maximal tolerated (90)Y dose, and is a potential new therapeutic for advanced pancreatic cancer. ©2011 AACR.

  15. 111In and 90Y labelled peptide radiopharmaceuticals for diagnosis and therapy

    International Nuclear Information System (INIS)

    Obenaus, E.; Crudo, J.L.; Castiglia, S.G. de

    2004-01-01

    Full text: The application of 111In-labelled octreotide to target somatostatin receptors on tumour cells has gained acceptance as a diagnostic procedure for demonstrating neuroendocrine and other SSTR-positive tumors. A further advance in the field of somatostatin analogues is the development of macrocyclic chelators that also bind beta particle emitters like 90Y and 177Lu. [90Y-DOTA, Tyr3] octreotide and [177Lu-DOTA, Tyr3] octreotate are currently being tried as the therapeutic agents. The aim of this work was to label two somatostatin analogues (Tyr3 Octreotide and Lanreotide) with 111In and 90Y using DOTA (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid) as a chelating agent. DOTA in the form of the tri-t-butyl ester was coupled to the Lys5 (BOC) protected Tyr3octreotide and Lys5 (BOC) protected lanreotide in N,N-dimethylformamide, in a three-step reaction involving conjugation, using HATU and diisopropylethylamine as coupling reagents, de-protection with trifluoroacetic and HPLC purification of the conjugates. The DOTALAN and DOTATOC were labelled with 111In and 90Y and assayed by HPLC. In both cases solutions of gentisic acid in sodium acetate 0.4M pH=5.0 and conjugated peptides were added to the 111In or 90Y chloride. The final solution was heated at 90 deg. C for 25 minutes. We tried different amounts of the two peptide complexes per mCi of 111In/90Y and quality control of the labelled products was performed with the following HPLC system: reverse phase column, flow rate 1ml-min, UV/radiometric detection and a gradient solvent: solvent A: acetonitrile, solvent B: water TFA 0.1%, gradient: 0-3min 100% B, linear increase of eluent A to 50% from 3-13 min, 13-18 min 50% A, 18-20 min linear increase of eluent A to 70%. Serum stability was determined after 4 and 24 hr. incubation of the labeled peptide in human serum at 37 deg. C. After precipitation of proteins with acetonitrile the incubation mixture was analyzed by HPLC. Normal Wistar rats were

  16. Assessing Intra-arterial Complications of Planning and Treatment Angiograms for Y-90 Radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Osman, E-mail: osman1423@gmail.com [Rush University Medical Center, Section of Interventional Radiology, Department of Radiology (United States); Patel, Mikin V. [University of Chicago, Department of Radiology (United States); Masrani, Abdulrahman; Chong, Bradford; Osman, Mohammed; Tasse, Jordan; Soni, Jayesh; Turba, Ulku Cenk; Arslan, Bulent [Rush University Medical Center, Section of Interventional Radiology, Department of Radiology (United States)

    2017-05-15

    PurposeTo report hepatic arterial-related complications encountered during planning and treatment angiograms for radioembolization and understand any potential-associated risk factors.Materials and Methods518 mapping or treatment angiograms for 180 patients with primary or metastatic disease to the liver treated by Yttrium-90 radioembolization between 2/2010 and 12/2015 were retrospectively reviewed. Intra-procedural complications were recorded per SIR guidelines. Patient demographics, indication for treatment, prior exposure to chemotherapeutic agents, operator experience, and disease burden were reviewed. Technical variables including type of radioembolic (glass vs. resin microspheres), indication for angiography (mapping vs. treatment), variant anatomy, and attempts at coil embolization were also assessed.ResultsThirteen (13/518, 2.5%) arterial-related complications occurred in 13 patients. All but two complications resulted during transcatheter coil embolization to prevent non-target embolization. Complications included coil migration (n = 6), arterial dissection (n = 2), focal vessel perforation (n = 2), arterial thrombus (n = 2), and vasospasm prohibiting further arterial sub-selection (n = 1). Transarterial coiling was identified as a significant risk factor of complications on both univariate and multivariate regression analysis (odds ratio 7.8, P = 0.004). Usage of resin microspheres was also a significant risk factor (odds ratio 9.5, P = 0.042). No other technical parameters or pre-procedural variables were significant after adjusting for confounding on multivariate analysis (P > 0.05).ConclusionIntra-procedural hepatic arterial complications encountered during radioembolization were infrequent but occurred mainly during coil embolization to prevent non-target delivery to extra-hepatic arteries.

  17. Role of diluent on the separation of {sup 90}Y from {sup 90}Sr by solvent extraction and supported liquid membrane using T2EHDGA as the extractant

    Energy Technology Data Exchange (ETDEWEB)

    Dutta, S. [Planning and Coordination Division, Bhabha Atomic Research Centre, Trombay, Mumbai - 400 085 (India); Raut, D.R. [Radiochemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai - 400 085 (India); Mohapatra, P.K., E-mail: mpatra@barc.gov.in [Radiochemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai - 400 085 (India)

    2012-04-15

    The separation behaviour of {sup 90}Y from {sup 90}Sr was investigated by diluent variation using solvent extraction and supported liquid membrane techniques employing N,N,N Prime ,N Prime -tetra-2-ethylhexyldiglycolamide (T2EHDGA) as the extractant. Both D{sub Y} (distribution ratio of Y(III)) and S.F. (separation factor) were found to be high in the solvent extraction studies when chloroform was used as the diluent. Subsequent supported liquid membrane (SLM) studies using PTFE flat sheet membranes containing 0.2 M T2EHDGA in various diluents indicated the trend of Y transport as xylene>hexone>chloroform>carbon tetrachloride>n-dodecane+30% iso-decanol mixture. However, the Sr(II) transport rates were also high with xylene, hexone, and carbon tetrachloride as the diluents which led us to carry out subsequent studies using chloroform and n-dodecane+30% iso-decanol mixture. Acid variation studies in chloroform system indicated an interesting phenomena of increasing Y(III) transport and decreasing Sr(II) transport with increasing acid concentration. Separation of {sup 90}Y from a mixture of {sup 90}Sr and {sup 90}Y was also attempted. - Highlights: Black-Right-Pointing-Pointer SLM studies using PTFE flat sheet membranes containing T2EHDGA as carrier was carried out for Y-90 separation from Sr-90. Black-Right-Pointing-Pointer The trend of Y transport as xylene>hexone>chloroform>carbon tetrachloride>n-dodecane+30% iso-decanol mixture. Black-Right-Pointing-Pointer Acid variation studies in chloroform system indicated an interesting phenomena of increasing Y(III) transport and decreasing Sr(II) transport with increasing acid concentration. Black-Right-Pointing-Pointer The present studies suggested that T2EHDGA-SLM show limited promise if coupled to another separation method such as extraction chromatography.

  18. WE-AB-204-02: Molecular-Imaging Based Assessment of Liver Complications for Yttrium-90 Microsphere Treatments: Can Existing NTCP Models Explain Clinical Outcomes?

    Energy Technology Data Exchange (ETDEWEB)

    Lin, M; Choi, E; Chuong, M; Saboury, B; Moeslein, F; D’Souza, W; Guerrero, M [University of Maryland School of Medicine, Baltimore, MD (United States)

    2015-06-15

    Purpose: To evaluate weather the current radiobiological models can predict the normal liver complications of radioactive Yttrium-90 ({sup 90}Y) selective-internal-radiation-treatment (SIRT) for metastatic liver lesions based on the post-infusion {sup 90}Y PET images. Methods: A total of 20 patients with metastatic liver tumors treated with SIRT that received a post-infusion {sup 90}Y-PET/CT scan were analyzed in this work. The 3D activity distribution of the PET images was converted into a 3D dose distribution via a kernel convolution process. The physical dose distribution was converted into the equivalent dose (EQ2) delivered at 2 Gy based on the linear-quadratic (LQ) model considering the dose rate effect. The biological endpoint of this work was radiation-induce liver disease (RILD). The NTCPs were calculated with four different repair-times (T1/2-Liver-Repair= 0,0.5,1.0,2.0 hr) and three published NTCP models (Lyman-external-RT, Lyman 90Y-HCC-SIRT, parallel model) were compared to the incidence of RILD of the recruited patients to evaluate their ability of outcome prediction. Results: The mean normal liver physical dose (avg. 51.9 Gy, range 31.9–69.8 Gy) is higher than the suggested liver dose constraint for external beam treatment (∼30 Gy). However, none of the patients in our study developed RILD after the SIRT. The estimated probability of ‘no patient developing RILD’ obtained from the two Lyman models are 46.3% to 48.3% (T1/2-Liver-Repair= 0hr) and <1% for all other repair times. For the parallel model, the estimated probability is 97.3% (0hr), 51.7% (0.5hr), 2.0% (1.0hr) and <1% (2.0hr). Conclusion: Molecular-images providing the distribution of {sup 90}Y enable the dose-volume based dose/outcome analysis for SIRT. Current NTCP models fail to predict RILD complications in our patient population, unless a very short repair-time for the liver is assumed. The discrepancy between the Lyman {sup 90}Y-HCC-SIRT model predicted and the clinically

  19. Hepatic arterial 90Yttrium glass microspheres (Therasphere) for unresectable hepatocellular carcinoma: interim safety and survival data on 65 patients.

    Science.gov (United States)

    Carr, Brian I

    2004-02-01

    Hepatocellular carcinoma (HCC) generally arises in a cirrhotic liver and, in most cases, is multifocal and bilobar. Although trans-hepatic artery chemoembolization (TACE) can be highly affective in shrinking tumors, it is limited by virtue of the damage that it can cause to the liver that is already damaged by chronic disease. A high priority in HCC research, after primary prevention and early detection, is to find new treatment modalities that are both effective and non-toxic to the underlying cirrhotic liver. A cohort of 65 patients with biopsy-proven unresectable HCC have been treated with hepatic arterial 90Yttrium microspheres (Therasphere), and the interim results are reported here. Only 1 cycle of Therasphere treatment ever was performed on 46 patients, 17 patients had 2 cycles, and 2 patients had 3 cycles of therapy. The median dose delivered was 134 Gy, typically as either 5 or 10 GBq (2-4 million microspheres). Clinical toxicities include 9 episodes of abdominal pain and 2 episodes of acute cholecystitis, requiring cholecystectomy. A main lab toxicity was elevated bilirubin which increased by more than 200% in 25 patients (30.5%) during 6 months of therapy, although 18 of these patients had only transient elevation. A prominent finding was prolonged and profound (>70%) lymphopenia in more than 75% of the patients, but without clinical significance. Forty-two patients (64.6%) had a substantial decrease in tumor vascularity in response to therapy, and 25 patients (38.4%) had a partial response, by computed tomography scan. Median survival for Okuda stage I patients (n=42) was 649 days (historical comparison 244) and for Okuda stage II patients (n=23) was 302 days (historical comparison 64 days). All patients were followed after therapy for a minimum of 6 months. There were 42 deaths, 21 due to liver failure, 6 from HCC progression, and 3 from metastases. Therasphere appears to be a relatively safe and effective therapy for advanced-stage unresectable HCC.

  20. Phase I/II 90Y-Zevalin (yttrium-90 ibritumomab tiuxetan, IDEC-Y2B8) radioimmunotherapy dosimetry results in relapsed or refractory non-Hodgkin's lymphoma

    International Nuclear Information System (INIS)

    Wiseman, G.A.; Dunn, W.L.; White, C.A.; Berlfein, J.R.; Ding, E.; Grillo-Lopez, A.J.; Stabin, M.; Erwin, W.; Spies, S.; Dahlbom, M.; Silverman, D.H.S.; Raubitschek, A.; Karvelis, K.; Schultheiss, T.; Witzig, T.E.; Belanger, R.

    2000-01-01

    Dosimetry studies in patients with non-Hodgkin's lymphoma were performed to estimate the radiation absorbed dose to normal organs and bone marrow from 90 Y-Zevalin (yttrium-90 ibritumomab tiuxetan, IDEC-Y2B8) treatment in this phase I/II, multicenter trial. The trial was designed to determine the dose of Rituximab (chimeric anti-CD20, Rituxan, IDEC-C2B8, MabThera), the unlabeled antibody given prior to the radioconjugate to clear peripheral blood B cells and optimize distribution, and to determine the maximum tolerated dose of 90 Y-Zevalin [7.4, 11, or 15 MBq/kg (0.2, 0.3, or 0.4 mCi/kg)]. Patients received 111 In-Zevalin (indium-111 ibritumomab tiuxetan, IDEC-In2B8) on day 0 followed by a therapeutic dose of 90 Y-Zevalin on day 7. Both doses were preceded by an infusion of the chimeric, unlabeled antibody Rituximab. Following administration of 111 In-Zevalin, serial anterior/posterior whole-body scans were acquired. Major-organ radioactivity versus time estimates were calculated using regions of interest. Residence times were computed and entered into the MIRDOSE3 computer software program to calculate estimated radiation absorbed dose to each organ. Initial analyses of estimated radiation absorbed dose were completed at the clinical site. An additional, centralized dosimetry analysis was performed subsequently to provide a consistent analysis of data collected from the seven clinical sites. In all patients with dosimetry data (n=56), normal organ and red marrow radiation absorbed doses were estimated to be well under the protocol-defined upper limit of 20 Gy and 3 Gy, respectively. Median estimated radiation absorbed dose was 3.4 Gy to liver (range 1.2-7.8 Gy), 2.6 Gy to lungs (range 0.72-4.4 Gy), and 0.38 Gy to kidneys (range 0.07-0.61 Gy). Median estimated tumor radiation absorbed dose was 17 Gy (range 5.8-67 Gy). No correlation was noted between hematologic toxicity and the following variables: red marrow radiation absorbed dose, blood T 1/2 , blood AUC

  1. Toxicity of 90Y in a relatively insoluble form inhaled by Beagle dogs. XIV

    International Nuclear Information System (INIS)

    Hahn, F.F.; Hobbs, C.H.; Kusewitt, D.F.; McClellan, R.O.; Mauderly, J.L.; Pickrell, J.A.

    1982-01-01

    The metabolism, dosimetry and biological effects of inhaled 90 Y in fused aluminosilicate particles in Beagle dogs are being studied. Eighty-nine dogs with initial lung burdens ranging from 80 to 5200 μCi 90 Y/kg body weight and 12 control dogs are being maintained for life span observations. The lung burdens achieved, short physical half-life and relative insolubility of the 90 Y in this vector resulted in a relatively high, rapidly decreasing radiation dose rate to the lung. To date, 69 exposed dogs have died; 38 from radiation pneumonitis, seven with pulmonary neoplasms and 24 from other causes. Four control dogs have died. Twenty-nine surviving exposed and eight control dogs are being studied for their life spans

  2. 90Sr- 90Y and 89Sr beta radioactivity measurement in milk samples using a proportional counter

    International Nuclear Information System (INIS)

    Mananes, A.; Perez Santos, C.; Martinez Churiaque, F.

    1987-01-01

    A thin window glas flow proportional counter is used to measure the 90 Sr- 90 Y and 89 Sr beta radioactivity in milk samples. A chemical procedure is used to separate strontium-yttrium from the other radionuclides present in milk. A calculation of the total efficiency of the system is performed which includes an empirical estimation of the backscattering factor. The calibration of the whole process allows the determination of the 90 Sr activity within 10% relative error in spite of uncertainties in the recovery yields of strontium and yttrium. No 89 Sr activity has been detected, and the mean value obtained for the 90 Sr activity in nine milk samples of Cantabria is 0.115 Bq/1 with a minimum detectable activity of 0.0105 Bq. (author) 18 refs

  3. Labeling an anti-CD20 monoclonal antibody with 90Y

    International Nuclear Information System (INIS)

    Perera Pintado, Alejandro; Leyva Montaña, René; Prats Capote, Anaís; Góngora Bravo, Magdiel; Alberti Ramírez, Alejandro; León, Mariela; Hernández González, Ignacio; Dorvignit, Denise

    2016-01-01

    Lymphomas are among the 10 leading causes of death, both in Cuba and in the world, with an increasing incidence in recent years. Follicular lymphoma low-grade (indolent) is one of the most common in the Western world, representing 1/3 of all non-Hodgkin lymphomas (NHL). More than 90% of patients present with disseminated disease at diagnosis and generally have a slow evolution and good response to conventional treatment; but radically changed its forecast to relapse, resistance to therapeutic and histologic transformation can occur. The monoclonal antibody therapy has been a promising therapeutic. In this respect CD20 antigen it has been considered one of the most attractive targets in the therapy of follicular B cell lymphoma This is expressed in more than 90% of cases, while not present in stem cells and lines progenitors. Despite the success of immunotherapy, the relapse rate is still considerable. In order to increase the cytotoxic potential of immunotherapy, marked with beta emitting radionuclides alpha particles or monoclonal antibodies are used today. Despite encouraging results in patients with non-Hodgkin lymphomas refractory to other treatments, the extremely high costs of these commercial radiopharmaceuticals have greatly limited its application, even in the first world. A sustainable alternative is the marking of other anti-CD20 monoclonal antibodies, so researchers from several countries have concentrated their efforts on rituximaby other similar antibodies labeled with therapeutic radionuclides, as a possible cost-effectively to more problem. Today in Cuba it has an electrolytic generator 90 Sr- 90 Y Isotope Center, which ensures the availability of the radionuclide. In addition, the chimeric MAb rituximab is applied as part of the therapy of NHL in its health system and, recently, the Center for Molecular Immunology has obtained a chimeric monoclonal anti-CD20 antibody biosimilar rituximab, which is in phase clinical trial; which opens prospects for

  4. Extraction and encapsulation of prodigiosin in chitosan microspheres for targeted drug delivery

    Energy Technology Data Exchange (ETDEWEB)

    Dozie-Nwachukwu, S.O. [Department of Materials Science and Engineering, African University of Science and Technology (AUST) Abuja, Federal Capital Territory (Nigeria); Biotechnology and Genetic Engineering Advanced Laboratory, Sheda Science and Technology Complex (SHESTCO), P.M.B 186, Garki, Abuja, Federal Capital Territory (Nigeria); Danyuo, Y. [Department of Materials Science and Engineering, African University of Science and Technology (AUST) Abuja, Federal Capital Territory (Nigeria); Department of Materials Science and Engineering, Kwara State University, Malete (Nigeria); Obayemi, J.D. [Department of Materials Science and Engineering, African University of Science and Technology (AUST) Abuja, Federal Capital Territory (Nigeria); Department of Mechanical and Aerospace Engineering, Princeton University, Princeton, NJ 08544 (United States); Odusanya, O.S. [Department of Materials Science and Engineering, African University of Science and Technology (AUST) Abuja, Federal Capital Territory (Nigeria); Biotechnology and Genetic Engineering Advanced Laboratory, Sheda Science and Technology Complex (SHESTCO), P.M.B 186, Garki, Abuja, Federal Capital Territory (Nigeria); Malatesta, K. [Department of Mechanical and Aerospace Engineering, Princeton University, Princeton, NJ 08544 (United States); Soboyejo, W.O., E-mail: soboyejo@princeton.edu [Department of Materials Science and Engineering, African University of Science and Technology (AUST) Abuja, Federal Capital Territory (Nigeria); Department of Mechanical and Aerospace Engineering, Princeton University, Princeton, NJ 08544 (United States); Princeton Institute of Science and Technology of Materials (PRISM), Bowen Hall, 70 Prospect Street, Princeton, NJ 08544 (United States)

    2017-02-01

    The encapsulation of drugs in polymeric materials has brought opportunities to the targeted delivery of chemotherapeutic agents. These polymeric delivery systems are capable of maximizing the therapeutic activity, as well as reducing the side effects of anti-cancer agents. Prodigiosin, a secondary metabolite extracted from the bacteria, Serratia marcescens, exhibits anti-cancer properties. Prodigiosin-loaded chitosan microspheres were prepared via water-in-oil (w/o) emulsion technique, using glutaraldehyde as a cross-linker. The morphologies of the microspheres were studied using scanning electron microscopy. The average sizes of the microspheres were between 40 μm and 60 μm, while the percentage yields ranged from 42 ± 2% to 55.5 ± 3%. The resulting encapsulation efficiencies were between 66.7 ± 3% and 90 ± 4%. The in-vitro drug release from the microspheres was characterized by zeroth order, first order and Higuchi and Korsmeyer-Peppas models. - Highlights: • Prodigiosin of ~ 92.8% purity was extracted from locally isolated Serratia marcescens. • This approach reduces the cost and ensure availability of drugs for cancer treatment. • High encapsulation efficiency which increased with increasing drug:polymer ratio • The percentage yield was generally poor due to the recovery process. • Prodigiosin greatly reduced the viability of the breast cancer cell line (MDA-MB-231).

  5. Extraction and encapsulation of prodigiosin in chitosan microspheres for targeted drug delivery

    International Nuclear Information System (INIS)

    Dozie-Nwachukwu, S.O.; Danyuo, Y.; Obayemi, J.D.; Odusanya, O.S.; Malatesta, K.; Soboyejo, W.O.

    2017-01-01

    The encapsulation of drugs in polymeric materials has brought opportunities to the targeted delivery of chemotherapeutic agents. These polymeric delivery systems are capable of maximizing the therapeutic activity, as well as reducing the side effects of anti-cancer agents. Prodigiosin, a secondary metabolite extracted from the bacteria, Serratia marcescens, exhibits anti-cancer properties. Prodigiosin-loaded chitosan microspheres were prepared via water-in-oil (w/o) emulsion technique, using glutaraldehyde as a cross-linker. The morphologies of the microspheres were studied using scanning electron microscopy. The average sizes of the microspheres were between 40 μm and 60 μm, while the percentage yields ranged from 42 ± 2% to 55.5 ± 3%. The resulting encapsulation efficiencies were between 66.7 ± 3% and 90 ± 4%. The in-vitro drug release from the microspheres was characterized by zeroth order, first order and Higuchi and Korsmeyer-Peppas models. - Highlights: • Prodigiosin of ~ 92.8% purity was extracted from locally isolated Serratia marcescens. • This approach reduces the cost and ensure availability of drugs for cancer treatment. • High encapsulation efficiency which increased with increasing drug:polymer ratio • The percentage yield was generally poor due to the recovery process. • Prodigiosin greatly reduced the viability of the breast cancer cell line (MDA-MB-231).

  6. Country report: Cuba. Local Production of 90Y And 188Re Radionuclides and Development of Radiopharmaceuticals for Therapy

    International Nuclear Information System (INIS)

    Xiques, Abmel; Hernández, Ignacio; Leyva, René; Pérez, Marylaine; Alonso, Luis Michel; Zamora, Minelys

    2010-01-01

    During the first period of this CRP we could test an efficient and reliable generator system based on ion-chromatography to obtain 90 Y from its parent radionuclide 90 Sr. This production scheme for 90 Y was outlined in the previous CRP related with the development of generator technologies. Quality parameters such as trace metals that can potentially interfere in the labeling of biomoléculas, 90 Y recovery, 90 Sr/ 90 Y ratio and radiation dose to bed matrix were evaluated. The results showed that high recovery and radionuclidic purity could be obtained for 90 Y during its repeated separation from the 90 Sr cow. No replacement or treatment of the cow were necessary and low waste generation and 90 Sr losses less that 0.1% after each run were also observed during the present study. A Fab’ fragment was enzimatically produced and purified from the monoclonal antibody h-R3 (Nimotuzumab®). The fragment and the parent antibody were successfully conjugated with DOTA and labeled with 90 Y. The radioinmunoconjugate thus obtained also exhibited a good 24 h in-vitro stability in an excess of DTPA. A 90 Y radiocoloid was prepared in a cromic phosphate particle for radiosynoviorthesis with promising results in animal models. Two alumina based 188 W/ 188 Re generators were prepared and their eluates were used in the labeling of hR3-DOTA conjugates. Quality control and in vivo evaluation in comparison with 99m Tc-hR3 showed very good results and similar pattern of distribution and pharmacokinetic and will be used in clinical trials for cancer patients. (author)

  7. PLGA/alginate composite microspheres for hydrophilic protein delivery

    International Nuclear Information System (INIS)

    Zhai, Peng; Chen, X.B.; Schreyer, David J.

    2015-01-01

    Poly(lactic-co-glycolic acid) (PLGA) microspheres and PLGA/alginate composite microspheres were prepared by a novel double emulsion and solvent evaporation technique and loaded with bovine serum albumin (BSA) or rabbit anti-laminin antibody protein. The addition of alginate and the use of a surfactant during microsphere preparation increased the encapsulation efficiency and reduced the initial burst release of hydrophilic BSA. Confocal laser scanning microcopy (CLSM) of BSA-loaded PLGA/alginate composite microspheres showed that PLGA, alginate, and BSA were distributed throughout the depths of microspheres; no core/shell structure was observed. Scanning electron microscopy revealed that PLGA microspheres erode and degrade more quickly than PLGA/alginate composite microspheres. When loaded with anti-laminin antibody, the function of released antibody was well preserved in both PLGA and PLGA/alginate composite microspheres. The biocompatibility of PLGA and PLGA/alginate microspheres were examined using four types of cultured cell lines, representing different tissue types. Cell survival was variably affected by the inclusion of alginate in composite microspheres, possibly due to the sensitivity of different cell types to excess calcium that may be released from the calcium cross-linked alginate. - Highlights: • A double emulsion technique is used to prepare protein-loaded PLGA or PLGA/alginate microspheres. • PLGA, alginate and protein are distributed evenly within microsphere structure. • Addition of alginate improves loading efficiency and slows degradation and protein release. • PLGA/alginate microspheres have favorable biocompatibility

  8. PLGA/alginate composite microspheres for hydrophilic protein delivery

    Energy Technology Data Exchange (ETDEWEB)

    Zhai, Peng [Department of Anatomy and Cell Biology, University of Saskatchewan, S7N5E5 (Canada); Division of Biomedical Engineering, University of Saskatchewan, S7N5A9 (Canada); Chen, X.B. [Department of Mechanical Engineering, University of Saskatchewan, S7N5A9 (Canada); Division of Biomedical Engineering, University of Saskatchewan, S7N5A9 (Canada); Schreyer, David J., E-mail: david.schreyer@usask.ca [Department of Anatomy and Cell Biology, University of Saskatchewan, S7N5E5 (Canada); Division of Biomedical Engineering, University of Saskatchewan, S7N5A9 (Canada)

    2015-11-01

    Poly(lactic-co-glycolic acid) (PLGA) microspheres and PLGA/alginate composite microspheres were prepared by a novel double emulsion and solvent evaporation technique and loaded with bovine serum albumin (BSA) or rabbit anti-laminin antibody protein. The addition of alginate and the use of a surfactant during microsphere preparation increased the encapsulation efficiency and reduced the initial burst release of hydrophilic BSA. Confocal laser scanning microcopy (CLSM) of BSA-loaded PLGA/alginate composite microspheres showed that PLGA, alginate, and BSA were distributed throughout the depths of microspheres; no core/shell structure was observed. Scanning electron microscopy revealed that PLGA microspheres erode and degrade more quickly than PLGA/alginate composite microspheres. When loaded with anti-laminin antibody, the function of released antibody was well preserved in both PLGA and PLGA/alginate composite microspheres. The biocompatibility of PLGA and PLGA/alginate microspheres were examined using four types of cultured cell lines, representing different tissue types. Cell survival was variably affected by the inclusion of alginate in composite microspheres, possibly due to the sensitivity of different cell types to excess calcium that may be released from the calcium cross-linked alginate. - Highlights: • A double emulsion technique is used to prepare protein-loaded PLGA or PLGA/alginate microspheres. • PLGA, alginate and protein are distributed evenly within microsphere structure. • Addition of alginate improves loading efficiency and slows degradation and protein release. • PLGA/alginate microspheres have favorable biocompatibility.

  9. Total Lesion Glycolysis and Sequential (90)Y-Selective Internal Radiation Therapy in Breast Cancer Liver Metastases: Preliminary Results.

    Science.gov (United States)

    Bagni, Oreste; Filippi, Luca; Pelle, Giuseppe; Cianni, Roberto; Schillaci, Orazio

    2015-12-01

    To assess the prognostic role of total lesion glycolysis (TLG) in patients with breast cancer liver metastases (BCLM) after sequential lobar (90)Y-radioembolization ((90)Y-RE). Seventeen patients with bilobar BCLM underwent FDG PET/CT and TLG calculation before (90)Y-RE. The hepatic lobe with the highest TLG was treated in the first session. PET was performed 6 weeks postprocedure and decrease in TLG (ΔTLG) in the treated lobe was calculated before the second (90)Y administration. Subjects were divided in two groups (group 1: ΔTLG >50%, group 2: ΔTLG 50% and seven had a ΔTLG value 50% and ΔTLG <50% had a mean OS of 16.4 ± 0.6 and 10.3 ± 0.4 months, respectively (p < 0.001). Cox regression analysis demonstrated hepatic tumor load (p = 0.048) and ΔTLG as the only significant (p = 0.005) predictors of survival. ΔTLG after the first (90)Y administration agrees with final outcome in BCLM patients after separate sequential lobar (90)Y-RE.

  10. The somatostatin receptor-targeted radiotherapeutic [90Y-DOTA-dPhe1,Tyr3]octreotide (90Y-SMT 487) eradicates experimental rat pancreatic CA 20948 tumours

    International Nuclear Information System (INIS)

    Stolz, B.; Weckbecker, G.; Smith-Jones, P.M.; Albert, R.; Raulf, F.; Bruns, C.

    1998-01-01

    Somatostatin receptor-expressing tumours are potential targets for therapy with radiolabelled somatostatin analogues. We have synthesized a number of such analogues in the past and identified [DOTA-dPhe 1 , Tyr 3 ]octreotide (SMT 487) as the most promising candidate molecule because of its advantageous properties in cellular and in vivo tumour models. In the current paper we describe the radiotherapeutic effect of yttrium-90 labelled SMT 487 in Lewis rats bearing the somatostatin receptor-positive rat pancreatic tumour CA 20948. SMT 487 binds with nanomolar affinity to both the human and the rat somatostatin receptor subtype 2 (sst 2 ) (human sst 2 IC 50 =0.9 nM, rat sst 2 IC 50 =0.5 nM). In vivo, 90 Y-SMT 487 distributed rapidly to the sst 2 expressing CA 20948 rat pancreatic tumour, with a tumour-to-blood ratio of 49.15 at 24 h post injection. A single intravenous administration of 10 mCi/kg 90 Y-SMT 487 resulted in a complete remission of the tumours in five out of seven CA 20948 tumour-bearing Lewis rats. No regrowth of the tumours occurred 8 months post injection. Control animals that were treated with 30 μg/kg of unlabelled SMT 487 had to be sacrificed 10 days post injection due to excessive growth or necrotic areas on the tumour surface. Upon re-inoculation of tumour cells into those rats that had shown complete remission, the tumours disappeared after 3-4 weeks of moderate growth without any further treatment. The present study shows for the first time the curative potential of 90 Y-SMT 487-based radiotherapy for somatostatin receptor-expressing tumours. Clinical phase I studies with yttrium-labelled SMT 487 have started in September 1997. (orig.)

  11. Somatostatin-based radiopeptide therapy with [177Lu-DOTA]-TOC versus [90Y-DOTA]-TOC in neuroendocrine tumours

    International Nuclear Information System (INIS)

    Romer, A.; Seiler, D.; Brunner, P.; Ng, Q.K.T.; Mueller-Brand, J.; Marincek, N.; Walter, M.A.; Koller, M.T.; Maecke, H.R.; Rochlitz, C.; Briel, M.; Schindler, C.

    2014-01-01

    Somatostatin-based radiopeptide treatment is generally performed using the β-emitting radionuclides 90 Y or 177 Lu. The present study aimed at comparing benefits and harms of both therapeutic approaches. In a comparative cohort study, patients with advanced neuroendocrine tumours underwent repeated cycles of [ 90 Y-DOTA]-TOC or [ 177 Lu-DOTA]-TOC until progression of disease or permanent adverse events. Multivariable Cox regression and competing risks regression were employed to examine predictors of survival and adverse events for both treatment groups. Overall, 910 patients underwent 1,804 cycles of [ 90 Y-DOTA]-TOC and 141 patients underwent 259 cycles of [ 177 Lu-DOTA]-TOC. The median survival after [ 177 Lu-DOTA]-TOC and after [ 90 Y-DOTA]-TOC was comparable (45.5 months versus 35.9 months, hazard ratio 0.91, 95 % confidence interval 0.63-1.30, p = 0.49). Subgroup analyses revealed a significantly longer survival for [ 177 Lu-DOTA]-TOC over [ 90 Y-DOTA]-TOC in patients with low tumour uptake, solitary lesions and extra-hepatic lesions. The rate of severe transient haematotoxicities was lower after [ 177 Lu-DOTA]-TOC treatment (1.4 vs 10.1 %, p = 0.001), while the rate of severe permanent renal toxicities was similar in both treatment groups (9.2 vs 7.8 %, p = 0.32). The present results revealed no difference in median overall survival after [ 177 Lu-DOTA]-TOC and [ 90 Y-DOTA]-TOC. Furthermore, [ 177 Lu-DOTA]-TOC was less haematotoxic than [ 90 Y-DOTA]-TOC. (orig.)

  12. Somatostatin-based radiopeptide therapy with [177Lu-DOTA]-TOC versus [90Y-DOTA]-TOC in neuroendocrine tumours.

    Science.gov (United States)

    Romer, A; Seiler, D; Marincek, N; Brunner, P; Koller, M T; Ng, Q K T; Maecke, H R; Müller-Brand, J; Rochlitz, C; Briel, M; Schindler, C; Walter, M A

    2014-02-01

    Somatostatin-based radiopeptide treatment is generally performed using the β-emitting radionuclides (90)Y or (177)Lu. The present study aimed at comparing benefits and harms of both therapeutic approaches. In a comparative cohort study, patients with advanced neuroendocrine tumours underwent repeated cycles of [(90)Y-DOTA]-TOC or [(177)Lu-DOTA]-TOC until progression of disease or permanent adverse events. Multivariable Cox regression and competing risks regression were employed to examine predictors of survival and adverse events for both treatment groups. Overall, 910 patients underwent 1,804 cycles of [(90)Y-DOTA]-TOC and 141 patients underwent 259 cycles of [(177)Lu-DOTA]-TOC. The median survival after [(177)Lu-DOTA]-TOC and after [(90)Y-DOTA]-TOC was comparable (45.5 months versus 35.9 months, hazard ratio 0.91, 95% confidence interval 0.63-1.30, p = 0.49). Subgroup analyses revealed a significantly longer survival for [(177)Lu-DOTA]-TOC over [(90)Y-DOTA]-TOC in patients with low tumour uptake, solitary lesions and extra-hepatic lesions. The rate of severe transient haematotoxicities was lower after [(177)Lu-DOTA]-TOC treatment (1.4 vs 10.1%, p = 0.001), while the rate of severe permanent renal toxicities was similar in both treatment groups (9.2 vs 7.8%, p = 0.32). The present results revealed no difference in median overall survival after [(177)Lu-DOTA]-TOC and [(90)Y-DOTA]-TOC. Furthermore, [(177)Lu-DOTA]-TOC was less haematotoxic than [(90)Y-DOTA]-TOC.

  13. Hydrogen transport and storage in engineered glass microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Rambach, G.D.

    1994-04-20

    New, high-strength, hollow, glass microspheres filled with pressurized hydrogen exhibit storage densities which make them attractive for bulk hydrogen storage and transport. The hoop stress at failure of our engineered glass microspheres is about 150,000 psi, permitting a three-fold increase in pressure limit and storage capacity above commercial microspheres, which fail at wall stresses of 50,000 psi. For this project, microsphere material and structure will be optimized for storage capacity and charge/discharge kinetics to improve their commercial practicality. Microsphere production scale up will be performed, directed towards large-scale commercial use. Our analysis relating glass microspheres for hydrogen transport with infrastructure and economics` indicate that pressurized microspheres can be economically competitive with other forms of bulk rail and truck transport such as hydride beds, cryocarbons and pressurized tube transports. For microspheres made from advanced materials and processes, analysis will also be performed to identify the appropriate applications of the microspheres considering property variables, and different hydrogen infrastructure, end use, production and market scenarios. This report presents some of the recent modelling results for large beds of glass microspheres in hydrogen storage applications. It includes plans for experiments to identify the properties relevant to large-bed hydrogen transport and storage applications, of the best, currently producible, glass microspheres. This work began in March, 1994. Project successes will be manifest in the matching of cur-rent glass microspheres with a useful application in hydrogen bulk transport and storage, and in developing microsphere materials and processes that increase the storage density and reduce the storage energy requirement.

  14. Temperature influence in crystallinity of polymer microspheres

    International Nuclear Information System (INIS)

    Rezende, Cristiane de P.; Novack, Katia M.

    2011-01-01

    Drug delivery technology is evolving through the creation of new techniques of drug delivery effectively. The new methods used in drugs administration are based in microencapsulation process. Microsphere encapsulation modifies drug delivery bringing benefits and efficiency. In this work has been evaluated the influence of temperature in microspheres preparation. Microspheres were obtained by PMMA-co-PEG (COP) copolymer with indomethacin inserted in polymer matrix. Samples were characterized by SEM, DSC and XRD. SEM micrographs confirmed the formation of different sizes of microspheres and it was verified that higher temperatures make more crystalline microspheres. (author)

  15. Hierarchical Mn2O3 Microspheres In-Situ Coated with Carbon for Supercapacitors with Highly Enhanced Performances

    Science.gov (United States)

    Gong, Feilong; Lu, Shuang; Peng, Lifang; Zhou, Jing; Kong, Jinming; Jia, Dianzeng; Li, Feng

    2017-01-01

    Porous Mn2O3 microspheres have been synthesized and in-situ coated with amorphous carbon to form hierarchical C@Mn2O3 microspheres by first producing MnCO3 microspheres in solvothermal reactions, and then annealing at 500 °C. The self-assembly growth of MnCO3 microspheres can generate hollow structures inside each of the particles, which can act as micro-reservoirs to store biomass-glycerol for generating amorphous carbon onto the surfaces of Mn2O3 nanorods consisting of microspheres. The C@Mn2O3 microspheres, prepared at 500 °C, exhibit highly enhanced pseudocapacitive performances when compared to the particles after annealed at 400 °C and 600 °C. Specifically, the C@Mn2O3 microspheres prepared at 500 °C show high specific capacitances of 383.87 F g−1 at current density of 0.5 A g−1, and excellent cycling stability of 90.47% of its initial value after cycling for 5000 times. The asymmetric supercapacitors assembled with C@Mn2O3 microspheres after annealed at 500 °C and activated carbon (AC) show an energy density of up to 77.8 Wh kg−1 at power density of 500.00 W kg−1, and a maximum power density of 20.14 kW kg−1 at energy density of 46.8 Wh kg−1. We can attribute the enhanced electrochemical performances of the materials to their three-dimensional (3D) hierarchical structure in-situ coated with carbon. PMID:29168756

  16. Hierarchical Mn2O3 Microspheres In-Situ Coated with Carbon for Supercapacitors with Highly Enhanced Performances

    Directory of Open Access Journals (Sweden)

    Feilong Gong

    2017-11-01

    Full Text Available Porous Mn2O3 microspheres have been synthesized and in-situ coated with amorphous carbon to form hierarchical C@Mn2O3 microspheres by first producing MnCO3 microspheres in solvothermal reactions, and then annealing at 500 °C. The self-assembly growth of MnCO3 microspheres can generate hollow structures inside each of the particles, which can act as micro-reservoirs to store biomass-glycerol for generating amorphous carbon onto the surfaces of Mn2O3 nanorods consisting of microspheres. The C@Mn2O3 microspheres, prepared at 500 °C, exhibit highly enhanced pseudocapacitive performances when compared to the particles after annealed at 400 °C and 600 °C. Specifically, the C@Mn2O3 microspheres prepared at 500 °C show high specific capacitances of 383.87 F g−1 at current density of 0.5 A g−1, and excellent cycling stability of 90.47% of its initial value after cycling for 5000 times. The asymmetric supercapacitors assembled with C@Mn2O3 microspheres after annealed at 500 °C and activated carbon (AC show an energy density of up to 77.8 Wh kg−1 at power density of 500.00 W kg−1, and a maximum power density of 20.14 kW kg−1 at energy density of 46.8 Wh kg−1. We can attribute the enhanced electrochemical performances of the materials to their three-dimensional (3D hierarchical structure in-situ coated with carbon.

  17. Increasing sensitivity and angle-of-view of mid-wave infrared detectors by integration with dielectric microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Allen, Kenneth W., E-mail: kenneth.allen@gtri.gatech.edu; Astratov, Vasily N., E-mail: astratov@uncc.edu [Department of Physics and Optical Science, Center for Optoelectronics and Optical Communications, University of North Carolina at Charlotte, Charlotte, North Carolina 28223-0001 (United States); Air Force Research Laboratory, Sensors Directorate, Wright Patterson AFB, Ohio 45433 (United States); UES, Dayton, Ohio 45433 (United States); Abolmaali, Farzaneh [Department of Physics and Optical Science, Center for Optoelectronics and Optical Communications, University of North Carolina at Charlotte, Charlotte, North Carolina 28223-0001 (United States); Duran, Joshua M.; Ariyawansa, Gamini; Limberopoulos, Nicholaos I. [Air Force Research Laboratory, Sensors Directorate, Wright Patterson AFB, Ohio 45433 (United States); Urbas, Augustine M. [Air Force Research Laboratory, Materials and Manufacturing Directorate, Wright-Patterson AFB, Ohio 45433 (United States)

    2016-06-13

    We observed up to 100 times enhancement of sensitivity of mid-wave infrared photodetectors in the 2–5 μm range by using photonic jets produced by sapphire, polystyrene, and soda-lime glass microspheres with diameters in the 90–300 μm range. By finite-difference time-domain (FDTD) method for modeling, we gain insight into the role of the microspheres refractive index, size, and alignment with respect to the detector mesa. A combination of enhanced sensitivity with angle-of-view (AOV) up to 20° is demonstrated for individual photodetectors. It is proposed that integration with microspheres can be scaled up for large focal plane arrays, which should provide maximal light collection efficiencies with wide AOVs, a combination of properties highly attractive for imaging applications.

  18. 90Y/90 Sr electron induced damages in an essential eucalyptus oil related to the absorbed dose

    International Nuclear Information System (INIS)

    Heredia Cardona, J.A.; Diaz Rizo, O.; Martinez Luzardo, F.; Quert, R.

    2007-01-01

    A good irradiation geometry was achieved in order to carry out the irradiation of an essential eucalyptus oil with a 90 Y/ 90 Sr electron source. The Monte Carlo simulation code MCNP-4C was employed to determine the absorbed doses in this particular experimental configuration. It also helped us to understand which electrons (from an energetic point of view) were responsible for the damages. In order to identify the induced damages, the irradiated samples were studied by mass spectrometry. The obtained results were related to the absorbed doses determined by the computational simulation

  19. Absorbed doses to the main parts of eyeball due to use 90Sr + 90Y ophthalmic applicator

    International Nuclear Information System (INIS)

    Chen Lishu

    1993-05-01

    The ophthalmic radiotherapy dosimetry and some affecting factors are introduced. The distributions of absorbed doses to the main parts of a fresh eyeball such as the cornea, sclera, lens and anterior chamber, during the radiotherapy by using a 90 Sr + 90 Y ophthalmic applicator are presented. An tissue-equivalent extrapolation ionization chamber was used in the dose measurement. The reasonable doses during ophthalmic radiotherapy for different depths have been obtained. Therefore, the absorbed dose to the lens, the most sensitive organ, can be given. These data are useful for radiation protection in ophthalmic radiotherapy

  20. Large-scale purification of 90Sr from nuclear waste materials for production of 90Y, a therapeutic medical radioisotope.

    Science.gov (United States)

    Wester, Dennis W; Steele, Richard T; Rinehart, Donald E; DesChane, Jaquetta R; Carson, Katharine J; Rapko, Brian M; Tenforde, Thomas S

    2003-07-01

    A major limitation on the supply of the short-lived medical isotope 90Y (t1/2 = 64 h) is the available quantity of highly purified 90Sr generator material. A radiochemical production campaign was therefore undertaken to purify 1,500 Ci of 90Sr that had been isolated from fission waste materials. A series of alkaline precipitation steps removed all detectable traces of 137Cs, alpha emitters, and uranium and transuranic elements. Technical obstacles such as the buildup of gas pressure generated upon mixing large quantities of acid with solid 90Sr carbonate were overcome through safety features incorporated into the custom-built equipment used for 90Sr purification. Methods are described for analyzing the chemical and radiochemical purity of the final product and for accurately determining by gravimetry the quantities of 90Sr immobilized on stainless steel filters for future use.

  1. Large-scale purification of 90Sr from nuclear waste materials for production of 90Y, a therapeutic medical radioisotope

    International Nuclear Information System (INIS)

    Wester, D.W.; Steele, R.T.; Rinehart, D.E.; DesChane, J.R.; Carson, K.J.; Rapko, B.M.; Tenforde, T.S.

    2003-01-01

    A major limitation on the supply of the short-lived medical isotope 90 Y (t 1/2 =64 h) is the available quantity of highly purified 90 Sr generator material. A radiochemical production campaign was therefore undertaken to purify 1500 Ci of 90 Sr that had been isolated from fission waste materials. A series of alkaline precipitation steps removed all detectable traces of 137 Cs, alpha emitters, and uranium and transuranic elements. Technical obstacles such as the buildup of gas pressure generated upon mixing large quantities of acid with solid 90 Sr carbonate were overcome through safety features incorporated into the custom-built equipment used for 90 Sr purification. Methods are described for analyzing the chemical and radiochemical purity of the final product and for accurately determining by gravimetry the quantities of 90 Sr immobilized on stainless steel filters for future use

  2. Investigation of pharmaceuticals and medical devices containing 90Y extracted from high radioactive liquid waste in spent-fuel reprocessing

    International Nuclear Information System (INIS)

    Hosoma, Takashi

    2012-07-01

    Pharmaceuticals and medical devices containing radioactive 90 Y are realized, approved and placed on the international market where three products are available in Europe and the United States, and one product in Japan. These products are used not for diagnosis but for treatment by internal irradiation. It was estimated from the deliberative report of the approval in Japan that 90 Y was extracted in Europe from high radioactive liquid waste (HALW) yielded in spent-fuel reprocessing. In this report, products placed on the market and physical properties were reviewed, reasons of the realization and conditions to realize succeeding products were estimated, extraction method was compared with other methods, technical subjects, and relevant regulations were investigated. Although a medical device containing radioactive 90 Y has been studied in Japan and one pharmaceutical product was approved, a breakthrough would be necessary to put 90 Y utilization beyond alternative treatments. The breakthrough would become be promising; for example, if conventional treatments could be supported by technical development to deliver 90 Y more sharply to the target with shorter serum half-life. Extraction of 90 Y nuclide from HALW has advantages over thermal neutron irradiation of natural nuclide, a system is envisioned where 90 Sr as a parent nuclide is separated in the reprocessing then transported to and stored in a factory of radiopharmaceuticals followed by 90 Y extraction on demand. (author)

  3. A novel route for synthesis and growth formation of metal oxides microspheres: Insights from V_2O_3 microspheres

    International Nuclear Information System (INIS)

    Zhang, Yifu; Huang, Chi; Meng, Changgong; Hu, Tao

    2016-01-01

    Highly polydisperse V_2O_3 solid microspheres with large specific surface area were successfully synthesized via a facile hydrothermal decomposition of VOC_2O_4 solution. The morphology and composition were characterized by scanning electron microscopy (SEM), Energy dispersive spectrometer (EDS), X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD). V_2O_3 microspheres display an obvious Mott phase transition at −128.5 °C (cooling curve) and −114.5 °C (heating curve). Some parameters including the reaction temperature, concentration of VOC_2O_4, reaction time, surfactant, H_2C_2O_4 and precursor were briefly discussed to reveal the formation of V_2O_3 microspheres. It was found that the precursor is crucial for the fabrication of microsphere. A self-assembly growth mechanism was suggested to explain the growth process of microspheres and the autogenic CO and CO_2 gas served as the soft templates. Furthermore, this route was developed to synthesize different metal oxides microspheres, and it was found that AlO(OH), Fe_3O_4, Fe_2O_3, Co_3O_4, Cr_2O_3, MoO_2 and WO_3 microspheres were obtained. All the results showed this process was successfully explored as a methodology to synthesize different metal oxides microspheres using the gas as the templates by this facile hydrothermal route. - Highlights: • Highly uniform V_2O_3 solid microspheres were synthesized. • V_2O_3 microspheres display an obvious Mott phase transition. • The autogenic CO and CO_2 gas served as the soft templates for designed synthesis. • AlO(OH), Fe_3O_4, Fe_2O_3, Co_3O_4, Cr_2O_3, MoO_2 and WO_3 microspheres were obtained. • A methodology to synthesize different metal oxides microspheres was developed.

  4. Utility of Quantitative 99mTc-MAA SPECT/CT for 90yttrium-Labelled Microsphere Treatment Planning: Calculating Vascularized Hepatic Volume and Dosimetric Approach

    Science.gov (United States)

    Garin, Etienne; Rolland, Yan; Lenoir, Laurence; Pracht, Marc; Mesbah, Habiba; Porée, Philippe; Laffont, Sophie; Clement, Bruno; Raoul, Jean-Luc; Boucher, Eveline

    2011-01-01

    Objectives. The aim of this study was to assess the effectiveness of SPECT/CT for volume measurements and to report a case illustrating the major impact of SPECT/CT in calculating the vascularized liver volume and dosimetry prior to injecting radiolabelled yttrium-90 microspheres (Therasphere). Materials and Methods. This was a phantom study, involving volume measurements carried out by two operators using SPECT and SPECT/CT images. The percentage of error for each method was calculated, and interobserver reproducibility was evaluated. A treatment using Therasphere was planned in a patient with three hepatic arteries, and the quantitative analysis of SPECT/CT for this patient is provided. Results. SPECT/CT volume measurements proved to be accurate (mean error Therasphere used. Conclusions. MAA SPECT/CT is accurate for vascularized liver volume measurements, providing a valuable contribution to the therapeutic planning of patients with complex hepatic vascularization. PMID:21822489

  5. Magnetic susceptibility characterisation of superparamagnetic microspheres

    Science.gov (United States)

    Grob, David Tim; Wise, Naomi; Oduwole, Olayinka; Sheard, Steve

    2018-04-01

    The separation of magnetic materials in microsystems using magnetophoresis has increased in popularity. The wide variety and availability of magnetic beads has fuelled this drive. It is important to know the magnetic characteristics of the microspheres in order to accurately use them in separation processes integrated on a lab-on-a-chip device. To investigate the magnetic susceptibility of magnetic microspheres, the magnetic responsiveness of three types of Dynabeads microspheres were tested using two different approaches. The magnetophoretic mobility of individual microspheres is studied using a particle tracking system and the magnetization of each type of Dynabeads microsphere is measured using SQUID relaxometry. The magnetic beads' susceptibility is obtained at four different applied magnetic fields in the range of 38-70 mT for both the mobility and SQUID measurements. The susceptibility values in both approaches show a consistent magnetic field dependence.

  6. Radiolabeling optimization and reduced staff radiation exposure for high-dose 90Y-ibritumomab tiuxetan (HD-Zevalin)

    International Nuclear Information System (INIS)

    Papi, Stefano; Martano, Luigi; Garaboldi, Lucia; Rossi, Annalisa; Cremonesi, Marta; Grana, Chiara Maria; Paolucci, Daniele; Sansovini, Maddalena; Paganelli, Giovanni; Chinol, Marco

    2010-01-01

    Introduction: 90 Y-Zevalin labeling may cause severe finger radiation exposure, especially in high-dose protocols (HD-Zevalin), where up to 7.4 GBq could be injected. In this work, we optimized the labeling of HD-Zevalin with special regard to simplicity, speed, safety and radiation protection. Methods: Factors influencing labeling outcome (activity, specific activity, time, final volume, stability) were studied separately. The critical steps of a standard radiolabeling procedure were optimized to reduce finger exposure, developing an alternative labeling procedure and including a different 90 Y supplier. Finger doses were monitored by thermoluminescent dosimeters at each fingertip under anti-X gloves, considering both absolute values and values after normalization to 1.48 GBq. Results: Labeling of 90 Y-Zevalin was safe and reproducible up to 7.4 GBq with a simple and single-step procedure offering good stability for several hours. Radiolabeling specific activity was found critical, being kept at 740 MBq.mg -1 . Radiochemical purity values ≥98% were routinely achieved. The alternative procedure allowed a sensible reduction of finger dose, due to both the different 90 Y vial and the handling. Finger exposure was reduced from 6.6±4.3 to 3.1±0.8 mSv/1.48 GBq in the case of the original 90 Y vial and from 1.5±0.9 to 0.3±0.1 mSv/1.48 GBq using a shielded 90 Y vial. Conclusions: HD-Zevalin can be prepared in a safe and reproducible way, giving high radiochemical purity values, good stability and low finger exposure. This study may improve the safety of nuclear medicine professionals involved in the preparation of Zevalin.

  7. Method for sizing hollow microspheres

    Science.gov (United States)

    Farnum, E.H.; Fries, R.J.

    1975-10-29

    Hollow Microspheres may be effectively sized by placing them beneath a screen stack completely immersed in an ultrasonic bath containing a liquid having a density at which the microspheres float and ultrasonically agitating the bath.

  8. Meta-analysis: adjusted indirect comparison of drug-eluting bead transarterial chemoembolization versus 90Y-radioembolization for hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Ludwig, Johannes M.; Xing, Minzhi; Zhang, Di; Kim, Hyun S.

    2017-01-01

    To investigate comparative effectiveness of drug-eluting bead transarterial chemoembolization (DEB-TACE) versus Yttrium-90 ( 90 Y)-radioembolization for hepatocellular carcinoma (HCC). Studies comparing conventional (c)TACE versus 90 Y-radioembolization or DEB-TACE for HCC treatment were identified using PubMed/Medline, Embase, and Cochrane databases. The adjusted indirect meta-analytic method for effectiveness comparison of DEB-TACE versus 90 Y-radioembolization was used. Wilcoxon rank-sum test was used to compare baseline characteristics. A priori defined sensitivity analysis of stratified study subgroups was performed for primary outcome analyses. Publication bias was tested by Egger's and Begg's tests. Fourteen studies comparing DEB-TACE or 90 Y-radioembolization with cTACE were included. Analysis revealed a 1-year overall survival benefit for DEB-TACE over 90 Y-radioembolization (79 % vs. 54.8 %; OR: 0.57; 95 %CI: 0.355-0.915; p = 0.02; I-squared: 0 %; p > 0.5), but not for the 2-year (61 % vs. 34 %; OR: 0.65; 95%CI: 0.294-1.437; p = 0.29) and 3-year survival (56.4 % vs. 20.9 %; OR: 0.713; 95 % CI: 0.21-2.548; p = 0.62). There was significant heterogeneity in the 2- and 3-year survival analyses. The pooled median overall survival was longer for DEB-TACE (22.6 vs. 14.7 months). There was no significant difference in tumour response rate. DEB-TACE and 90 Y-radioembolization are efficacious treatments for patients suffering from HCC; DEB-TACE demonstrated survival benefit at 1-year compared to 90 Y-radioembolization but direct comparison is warranted for further evaluation. (orig.)

  9. Anti-CD45 radioimmunotherapy with 90Y but not 177Lu is effective treatment in a syngeneic murine leukemia model.

    Directory of Open Access Journals (Sweden)

    Johnnie J Orozco

    Full Text Available Radioimmunotherapy (RIT for treatment of hematologic malignancies has primarily employed monoclonal antibodies (Ab labeled with 131I or 90Y which have limitations, and alternative radionuclides are needed to facilitate wider adoption of RIT. We therefore compared the relative therapeutic efficacy and toxicity of anti-CD45 RIT employing 90Y and 177Lu in a syngeneic, disseminated murine myeloid leukemia (B6SJLF1/J model. Biodistribution studies showed that both 90Y- and 177Lu-anti-murine CD45 Ab conjugates (DOTA-30F11 targeted hematologic tissues, as at 24 hours 48.8 ± 21.2 and 156 ± 14.6% injected dose per gram of tissue (% ID/g of 90Y-DOTA-30F11 and 54.2 ± 9.5 and 199 ± 11.7% ID/g of 177Lu-DOTA-30F11 accumulated in bone marrow (BM and spleen, respectively. However, 90Y-DOTA-30F11 RIT demonstrated a dose-dependent survival benefit: 60% of mice treated with 300 µCi 90Y-DOTA-30F11 lived over 180 days after therapy, and mice treated with 100 µCi 90Y-DOTA-30F11 had a median survival 66 days. 90Y-anti-CD45 RIT was associated with transient, mild myelotoxicity without hepatic or renal toxicity. Conversely, 177Lu- anti-CD45 RIT yielded no long-term survivors. Thus, 90Y was more effective than 177Lu for anti-CD45 RIT of AML in this murine leukemia model.

  10. In vitro evaluation of biodegradable microspheres with surface-bound ligands.

    Science.gov (United States)

    Keegan, Mark E; Royce, Sara M; Fahmy, Tarek; Saltzman, W Mark

    2006-02-21

    Protein ligands were conjugated to the surface of biodegradable microspheres. These microsphere-ligand conjugates were then used in two in vitro model systems to evaluate the effect of conjugated ligands on microsphere behavior. Microsphere retention in agarose columns was increased by ligands on the microsphere surface specific for receptors on the agarose matrix. In another experiment, conjugating the lectin Ulex europaeus agglutinin 1 to the microsphere surface increased microsphere adhesion to Caco-2 monolayers compared to control microspheres. This increase in microsphere adhesion was negated by co-administration of l-fucose, indicating that the increase in adhesion is due to specific interaction of the ligand with carbohydrate receptors on the cell surface. These results demonstrate that the ligands conjugated to the microspheres maintain their receptor binding activity and are present on the microsphere surface at a density sufficient to target the microspheres to both monolayers and three-dimensional matrices bearing complementary receptors.

  11. Evaluation of a pyrex glass shield for the dose reduction in extremities to manipulate a 90 Sr- 90 Y generator

    International Nuclear Information System (INIS)

    Ayra P, F.E.; Xiques C, A.; Torres B, M.B.

    2006-01-01

    The production of Y-90 of high activity it specifies (free of payee) for their use in radioimmunotherapy uses the Strontium 90 as isotope source. Depending on the method employee for the separation of both isotopes several types of generators are described in different bibliographies. The column generator used in the facilities of the Center of Isotopes requires of a frequent manipulation causing significant dose in the skin of the extremities due to the exhibition to the radiation beta of high energy. The properties of the shieldings for this radiation type have been well studied Y they consist in several publications. To be in correspondence with requirements of radiological protection in the Cuban legislation, the column was covered with a tube of glass pyrex of 5 mm of thickness and it was monitored the exposure with an ionization chamber. At the own time, the shielding using the Monte Carlo method was evaluated. It was used the MCNP 4C code to simulate the absorption of the beta particles generated in the process of disintegration of the Sr-90 and Y-90 in the glass shielding. The column generator and the fluence of beta particles were modeled in different points inside the shielding to determine if the experimentally measured values correspond to electrons that were not absorbed or to the weak stopping radiation generated in the glass due to the deceleration of these particles. A cylinder of 4 mm of diameter simulates the source (it dilutes) and a tube of walls of 6 mm of thickness simulates the shielding more the wall of the column around the generator. This it was divided in cells of 1 mm of thickness and the energy deposited in them was evaluated. The results show that all the electrons generated in the source are absorbed in the shielding and the exposure rates decrease in more of 78 times using the 5 mm of pyrex glass. The doses in extremities to the operators of the generator don't surpass the 70 mSv by year that is the dose restriction imposed in the

  12. Efficacy and safety of selective internal radiotherapy with yttrium-90 resin microspheres compared with sorafenib in locally advanced and inoperable hepatocellular carcinoma (SARAH): an open-label randomised controlled phase 3 trial.

    Science.gov (United States)

    Vilgrain, Valérie; Pereira, Helena; Assenat, Eric; Guiu, Boris; Ilonca, Alina Diana; Pageaux, Georges-Philippe; Sibert, Annie; Bouattour, Mohamed; Lebtahi, Rachida; Allaham, Wassim; Barraud, Hélène; Laurent, Valérie; Mathias, Elodie; Bronowicki, Jean-Pierre; Tasu, Jean-Pierre; Perdrisot, Rémy; Silvain, Christine; Gerolami, René; Mundler, Olivier; Seitz, Jean-Francois; Vidal, Vincent; Aubé, Christophe; Oberti, Frédéric; Couturier, Olivier; Brenot-Rossi, Isabelle; Raoul, Jean-Luc; Sarran, Anthony; Costentin, Charlotte; Itti, Emmanuel; Luciani, Alain; Adam, René; Lewin, Maïté; Samuel, Didier; Ronot, Maxime; Dinut, Aurelia; Castera, Laurent; Chatellier, Gilles

    2017-12-01

    Sorafenib is the recommended treatment for patients with advanced hepatocellular carcinoma. We aimed to compare the efficacy and safety of sorafenib to that of selective internal radiotherapy (SIRT) with yttrium-90 ( 90 Y) resin microspheres in patients with hepatocellular carcinoma. SARAH was a multicentre, open-label, randomised, controlled, investigator-initiated, phase 3 trial done at 25 centres specialising in liver diseases in France. Patients were eligible if they were aged at least 18 years with a life expectancy greater than 3 months, had an Eastern Cooperative Oncology Group (ECOG) performance status of 0 or 1, Child-Pugh liver function class A or B score of 7 or lower, and locally advanced hepatocellular carcinoma (Barcelona Clinic Liver Cancer [BCLC] stage C), or new hepatocellular carcinoma not eligible for surgical resection, liver transplantation, or thermal ablation after a previously cured hepatocellular carcinoma (cured by surgery or thermoablative therapy), or hepatocellular carcinoma with two unsuccessful rounds of transarterial chemoembolisation. Patients were randomly assigned (1:1) by a permutated block method with block sizes two and four to receive continuous oral sorafenib (400 mg twice daily) or SIRT with 90 Y-loaded resin microspheres 2-5 weeks after randomisation. Patients were stratified according to randomising centre, ECOG performance status, previous transarterial chemoembolisation, and presence of macroscopic vascular invasion. The primary endpoint was overall survival. Analyses were done on the intention-to-treat population; safety was assessed in all patients who received at least one dose of sorafenib or underwent at least one of the SIRT work-up exams. This study has been completed and the final results are reported here. The trial is registered with ClinicalTrials.gov, number NCT01482442. Between Dec 5, 2011, and March 12, 2015, 467 patients were randomly assigned; after eight patients withdrew consent, 237 were assigned to

  13. Measurement of blood flow through surgical anastomosis using the radioactive microsphere technique

    Energy Technology Data Exchange (ETDEWEB)

    Hummel, S.J.; Delgado, G.; Butterfield, A.; Dritschilo, A.; Harbert, J.

    1985-10-01

    Two different radioactive microspheres ( U Ce and UWSc) were used to measure blood flow to an area of the large intestine in dogs before and after a surgical resection was performed with surgical staples. The healing of an anastomosis is theoretically related to the blood flow to the anastomotic site. Blood flow studies were conducted in three dogs using this technique. The average blood flow preoperatively was 0.558 mL/minute per gram and 1.04 mL/minute per gram postoperatively. These results indicate a statistically significant increase in blood flow at the anastomotic site six days after anastomosis when compared with the blood flow to the same area before any surgical procedures.

  14. Measurement of blood flow through surgical anastomosis using the radioactive microsphere technique

    International Nuclear Information System (INIS)

    Hummel, S.J.; Delgado, G.; Butterfield, A.; Dritschilo, A.; Harbert, J.

    1985-01-01

    Two different radioactive microspheres ( 141 Ce and 46 Sc) were used to measure blood flow to an area of the large intestine in dogs before and after a surgical resection was performed with surgical staples. The healing of an anastomosis is theoretically related to the blood flow to the anastomotic site. Blood flow studies were conducted in three dogs using this technique. The average blood flow preoperatively was 0.558 mL/minute per gram and 1.04 mL/minute per gram postoperatively. These results indicate a statistically significant increase in blood flow at the anastomotic site six days after anastomosis when compared with the blood flow to the same area before any surgical procedures

  15. Two-stage supported liquid membrane method for the separation of carrier-free {sup 90}Y from {sup 90}Sr using KSM-17 and CMPO as carriers

    Energy Technology Data Exchange (ETDEWEB)

    Dhami, P S; Naik, P W; Dudwadkar, N L; Kannan, R; Achuthan, P V; Dakshinamoorthy, A; Jambunathan, U; Munshi, S K; Dey, P K [Fuel Reprocessing Division, Bhabha Atomic Research Centre, Mumbai (India); Pandey, Usha; Venkatesh, Meera [Radiopharmaceuticals Division, Bhabha Atomic Research Centre, Mumbai (India)

    2007-07-01

    A two stage supported liquid membrane system is developed for the separation of carrier free {sup 90}Y from {sup 90}Sr for therapeutic applications. The feed containing {sup 90}Sr-{sup 90}Y in nitric acid solution at pH 2 is placed in the feed compartment and transported across a polytetrafluoroethylene membrane containing 2-ethyhexyl2ethylhexyl phosphonic acid to a 4M HNO{sub 3} receiver phase. This is then transported across another polytetrafluoroethylene membrane containing octyl phenyl N,N-diisobutylcarbamoyl methylphosphene oxide to another receiving phase, 1 M acetic acid. This has been implemented on simultaneous and sequential modes with very good yield. The second stage will act as a barrier for {sup 90}Sr, and will improve the product purity. (author)

  16. Intestinal absorption of PLAGA microspheres in the rat.

    Science.gov (United States)

    Damgé, C; Aprahamian, M; Marchais, H; Benoit, J P; Pinget, M

    1996-12-01

    Rhodamine B-labelled poly (DL-lactide-co-glycolide) (PLAGA) microspheres of 2 different sizes, 1-5 microns and 5-10 microns, were administered as a single dose (1.44 x 10(9) and 1.83 x 10(8) particles, respectively) into the ileal lumen of adult rats. The content of rhodamine in the mesenteric vein and ileal lumen was analysed periodically from 10 min to 48 h as well as the distribution of microspheres in the intestinal mucosa and various other tissues. The concentration of rhodamine decreased progressively in the intestinal lumen and was negligible after 24 h. The number of microspheres in the mesenteric vein increased rapidly and reached a maximum after 4 h whatever the size of the particles. It then decreased progressively, but more rapidly with microspheres > 5 microns than with microspheres PLAGA microspheres mainly crossed the intestinal mucosa at the site of Peyer's patches where microspheres of 5 microns were retained in the ileal lumen. A few small microspheres were occasionally observed in the epithelial cells. Only the smallest particles were recovered in the liver, lymph nodes and spleen while basement membranes were always labelled. It is concluded that PLAGA microspheres could be useful for the oral delivery of antigens if their size is between 1 and 5 microns.

  17. Gastroretentive Floating Microspheres of Silymarin: Preparation and ...

    African Journals Online (AJOL)

    Methods: Cellulose microspheres – formulated with hydroxylpropyl methylcellulose (HPMC) and ethyl cellulose (EC) – and Eudragit microspheres – formulated with Eudragit® S 100 (ES) and Eudragit® RL (ERL) - were prepared by an emulsion-solvent evaporation method. The floating microspheres were evaluated for flow ...

  18. Time optimization of 90Sr measurements: Sequential measurement of multiple samples during ingrowth of 90Y

    International Nuclear Information System (INIS)

    Holmgren, Stina; Tovedal, Annika; Björnham, Oscar; Ramebäck, Henrik

    2016-01-01

    The aim of this paper is to contribute to a more rapid determination of a series of samples containing 90 Sr by making the Cherenkov measurement of the daughter nuclide 90 Y more time efficient. There are many instances when an optimization of the measurement method might be favorable, such as; situations requiring rapid results in order to make urgent decisions or, on the other hand, to maximize the throughput of samples in a limited available time span. In order to minimize the total analysis time, a mathematical model was developed which calculates the time of ingrowth as well as individual measurement times for n samples in a series. This work is focused on the measurement of 90 Y during ingrowth, after an initial chemical separation of strontium, in which it is assumed that no other radioactive strontium isotopes are present. By using a fixed minimum detectable activity (MDA) and iterating the measurement time for each consecutive sample the total analysis time will be less, compared to using the same measurement time for all samples. It was found that by optimization, the total analysis time for 10 samples can be decreased greatly, from 21 h to 6.5 h, when assuming a MDA of 1 Bq/L and at a background count rate of approximately 0.8 cpm. - Highlights: • An approach roughly a factor of three more efficient than an un-optimized method. • The optimization gives a more efficient use of instrument time. • The efficiency increase ranges from a factor of three to 10, for 10 to 40 samples.

  19. Hydrogen transport and storage in engineered glass microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Rambach, G.D.

    1995-02-28

    New, high strength glass microspheres filled with pressurized hydrogen exhibit densities which make them attractive for bulk hydrogen storage and transport. The membrane tensile stress at failure for engineered glass microspheres is about 150,000 psi, permitting a three-fold increase in pressure limit and storage capacity above commercial microspheres, which have been studied a decade ago and have been shown to fail at membrane stresses of 50,000 psi. This analysis relating glass microspheres for hydrogen transport with infrastructure and economics, indicate that pressurized microspheres can be economically competitive with other forms of bulk rail and truck transport such as pressurized tube transports and liquid hydrogen trailers. This paper will describe the matching of current glass microspheres with the useful application in commercial hydrogen bulk transport and storage.

  20. Investigation on the influence of metal ion impurities on the complexation behavior of generator produced {sup 90}Y with bifunctional chelators

    Energy Technology Data Exchange (ETDEWEB)

    Pandey, Usha; Gamre, Naresh; Dash, Ashutosh [Isotope Applications and Radiopharmaceuticals Division, Bhabha Atomic Research Centre, Mumbai (India)

    2014-05-01

    The {sup 90}Sr/ {sup 90}Y generator is the exclusive source of 'no carrier added' {sup 90}Y for targeted therapy. However, the concomitant presence of trace metals diminishes the complexation of {sup 90}Y with bifunctional chelators (BFCs). A systematic investigation was performed to evaluate the influence of trace metals on the complexation of {sup 90}Y (from an electrochemical generator) with BFCs such as p-SCN-Bn-PCTA, p-SCN-Bn-DTPA and p-SCN-Bn-DOTA. Our study indicates that while p-SCN-Bn-DTPA was least affected by most of the trace metals studied, p-SCN-Bn-PCTA was most sensitive to their presence and hence could be the ligand of choice for assessing the chemical purity of generator derived {sup 90}Y. (author)

  1. A data acquisition system for indentification of 90Sr/ 90Y in environmental samples

    International Nuclear Information System (INIS)

    Medin, G.; Brajnik, D.; Starcic, M.; Stanovnik, A.

    1996-01-01

    Often, in the stage of research and development of new techniques for detection of ionizing radiation, elaborate electronic systems are required. In this paper, we describe the relatively complex detector and electronic system used for a relatively simple but nevertheless demanding measurement of the beta emitting radionuclides 90 Sr/ 90 Y in environmental samples. The detection limit of 1 Bq in a thin, disc-shaped sample, was obtained by careful elimination of background. Contribution of other radionuclides in the sample, were eliminated or at least considerably reduced by using a silica aerogel as Cherenkov radiator and thin multiwire chamber in coincidence. Cosmic ray signals were reduced by large scintillation counters in anticoincidence. Finally, persisting RF pick-up signals were eliminated by using the signal from a wire antenna and identical MWPC preamplifier and discriminator for a veto to the master coincidence. For each accepted event, both timing and pulse height information was recorded with a personal computer

  2. Characterization of an extrapolation chamber in a 90Sr/90Y beta radiation field

    International Nuclear Information System (INIS)

    Oramas Polo, I.; Tamayo Garcia, J. A.

    2015-01-01

    The extrapolation chamber is a parallel plate chamber and variable volume based on the Bragg-Gray theory. It determines in absolute mode, with high accuracy the dose absorbed by the extrapolation of the ionization current measured for a null distance between the electrodes. This camera is used for dosimetry of external beta rays for radiation protection. This paper presents the characterization of an extrapolation chamber in a 90 Sr/ 90 Y beta radiation field. The absorbed dose rate to tissue at a depth of 0.07 mm was calculated and is (0.13206±0.0028) μGy. The extrapolation chamber null depth was determined and its value is 60 μm. The influence of temperature, pressure and humidity on the value of the corrected current was also evaluated. Temperature is the parameter that has more influence on this value and the influence of pressure and the humidity is not very significant. Extrapolation curves were obtained. (Author)

  3. Successful Preoperative Chemoembolization in the Treatment of a Giant Malignant Phyllodes Tumor

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Kazuki, E-mail: kazkik1980@gmail.com; Mimura, Hidefumi; Arai, Yasunori [St. Marianna University School of Medicine, Department of Radiology (Japan); Doi, Masatomo [St. Marianna University School of Medicine, Department of Pathology (Japan); Kojima, Yasuyuki; Tsugawa, Koichiro [St. Marianna University School of Medicine, Division of Breast and Endocrine Surgery, Department of Surgery (Japan); Nakajima, Yasuo [St. Marianna University School of Medicine, Department of Radiology (Japan)

    2016-07-15

    The malignant phyllodes tumor is a relatively rare neoplasm and has not previously been a therapeutic target of interventional radiology. Herein, we report a successful case of preoperative chemoembolization of a giant malignant phyllodes tumor. The objective was to achieve sufficient tumor shrinkage before surgery to avoid the requirement for skin grafting after resection. Intra-arterial epirubicin infusion and subsequent embolization with Embosphere Microspheres (BioSphere Medical, Rockland, MA, USA) was undertaken three times over the course of 6 weeks and was well tolerated. The patient underwent surgery without skin grafting. Neither local recurrence nor distant metastasis was observed at 6 months after surgery.

  4. Successful Preoperative Chemoembolization in the Treatment of a Giant Malignant Phyllodes Tumor

    International Nuclear Information System (INIS)

    Hashimoto, Kazuki; Mimura, Hidefumi; Arai, Yasunori; Doi, Masatomo; Kojima, Yasuyuki; Tsugawa, Koichiro; Nakajima, Yasuo

    2016-01-01

    The malignant phyllodes tumor is a relatively rare neoplasm and has not previously been a therapeutic target of interventional radiology. Herein, we report a successful case of preoperative chemoembolization of a giant malignant phyllodes tumor. The objective was to achieve sufficient tumor shrinkage before surgery to avoid the requirement for skin grafting after resection. Intra-arterial epirubicin infusion and subsequent embolization with Embosphere Microspheres (BioSphere Medical, Rockland, MA, USA) was undertaken three times over the course of 6 weeks and was well tolerated. The patient underwent surgery without skin grafting. Neither local recurrence nor distant metastasis was observed at 6 months after surgery.

  5. Meta-analysis: adjusted indirect comparison of drug-eluting bead transarterial chemoembolization versus {sup 90}Y-radioembolization for hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Ludwig, Johannes M.; Xing, Minzhi [Yale School of Medicine, Division of Interventional Radiology, Department of Radiology and Biomedical Imaging, New Haven, CT (United States); Zhang, Di [University of Pittsburgh Graduate School of Public Health, Department of Biostatistics, Pittsburgh, PA (United States); Kim, Hyun S. [Yale School of Medicine, Division of Interventional Radiology, Department of Radiology and Biomedical Imaging, New Haven, CT (United States); Yale School of Medicine, Yale Cancer Center, New Haven, CT (United States)

    2017-05-15

    To investigate comparative effectiveness of drug-eluting bead transarterial chemoembolization (DEB-TACE) versus Yttrium-90 ({sup 90}Y)-radioembolization for hepatocellular carcinoma (HCC). Studies comparing conventional (c)TACE versus {sup 90}Y-radioembolization or DEB-TACE for HCC treatment were identified using PubMed/Medline, Embase, and Cochrane databases. The adjusted indirect meta-analytic method for effectiveness comparison of DEB-TACE versus {sup 90}Y-radioembolization was used. Wilcoxon rank-sum test was used to compare baseline characteristics. A priori defined sensitivity analysis of stratified study subgroups was performed for primary outcome analyses. Publication bias was tested by Egger's and Begg's tests. Fourteen studies comparing DEB-TACE or {sup 90}Y-radioembolization with cTACE were included. Analysis revealed a 1-year overall survival benefit for DEB-TACE over {sup 90}Y-radioembolization (79 % vs. 54.8 %; OR: 0.57; 95 %CI: 0.355-0.915; p = 0.02; I-squared: 0 %; p > 0.5), but not for the 2-year (61 % vs. 34 %; OR: 0.65; 95%CI: 0.294-1.437; p = 0.29) and 3-year survival (56.4 % vs. 20.9 %; OR: 0.713; 95 % CI: 0.21-2.548; p = 0.62). There was significant heterogeneity in the 2- and 3-year survival analyses. The pooled median overall survival was longer for DEB-TACE (22.6 vs. 14.7 months). There was no significant difference in tumour response rate. DEB-TACE and {sup 90}Y-radioembolization are efficacious treatments for patients suffering from HCC; DEB-TACE demonstrated survival benefit at 1-year compared to {sup 90}Y-radioembolization but direct comparison is warranted for further evaluation. (orig.)

  6. Efficiency calibration of a liquid scintillation counter for 90Y Cherenkov counting

    International Nuclear Information System (INIS)

    Vaca, F.; Garcia-Leon, M.

    1998-01-01

    In this paper a complete and self-consistent method for 90 Sr determination in environmental samples is presented. It is based on the Cherenkov counting of 90 Y with a conventional liquid scintillation counter. The effects of color quenching on the counting efficiency and background are carefully studied. A working curve is presented which allows to quantify the correction in the counting efficiency depending on the color quenching strength. (orig.)

  7. Innovative hydrogen storage in hollow glass-microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Keding, M.; Schmid, G.; Tajmar, M. [Austrian Research Centers, Vienna (Austria)

    2009-07-01

    Hydrogen storage technologies are becoming increasingly important for a number of future applications. The Austrian Research Centers (ARC) are developing a unique hydrogen storage system that combines the advantages of both hollow glass microsphere and chemical compound hydrogen storage, but eliminates their respective drawbacks. Water is utilized as a functional liquid to carry the hollow glass microspheres that are loaded with up to 700 bar of hydrogen gas. Sodium borohydride (NaBH{sub 4}) is then injected together with the glass microspheres into a reaction chamber where the water reacts catalytically with the NaBH{sub 4} producing hydrogen and heat. The heat is then utilized to release the hydrogen from the hollow glass microspheres providing a double hydrogen generation process without any external energy or heat during storage or gas release. The paper described this hydrogen storage system with particular reference to microspheres, the coating process, the experimental facility and NaBH{sub 4} test results. It was concluded that hydrogen storage and production on demand is possible with microspheres and sodium borohydride solution. 9 refs., 16 figs.

  8. Country report: Cuba. Local Production of {sup 90}Y And {sup 188}Re Radionuclides and Development of Radiopharmaceuticals for Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Xiques, Abmel; Hernández, Ignacio; Leyva, René; Pérez, Marylaine; Alonso, Luis Michel; Zamora, Minelys [Centro de Isotopos (CENTIS) (Cuba)

    2010-07-01

    During the first period of this CRP we could test an efficient and reliable generator system based on ion-chromatography to obtain {sup 90}Y from its parent radionuclide {sup 90}Sr. This production scheme for {sup 90}Y was outlined in the previous CRP related with the development of generator technologies. Quality parameters such as trace metals that can potentially interfere in the labeling of biomoléculas, {sup 90}Y recovery, {sup 90}Sr/{sup 90}Y ratio and radiation dose to bed matrix were evaluated. The results showed that high recovery and radionuclidic purity could be obtained for {sup 90}Y during its repeated separation from the {sup 90}Sr cow. No replacement or treatment of the cow were necessary and low waste generation and {sup 90}Sr losses less that 0.1% after each run were also observed during the present study. A Fab’ fragment was enzimatically produced and purified from the monoclonal antibody h-R3 (Nimotuzumab®). The fragment and the parent antibody were successfully conjugated with DOTA and labeled with {sup 90}Y. The radioinmunoconjugate thus obtained also exhibited a good 24 h in-vitro stability in an excess of DTPA. A {sup 90}Y radiocoloid was prepared in a cromic phosphate particle for radiosynoviorthesis with promising results in animal models. Two alumina based {sup 188}W/{sup 188}Re generators were prepared and their eluates were used in the labeling of hR3-DOTA conjugates. Quality control and in vivo evaluation in comparison with {sup 99m}Tc-hR3 showed very good results and similar pattern of distribution and pharmacokinetic and will be used in clinical trials for cancer patients. (author)

  9. Preparation of microspheres for slow release drug by radiation-induced suspension polymerization and their properties

    International Nuclear Information System (INIS)

    Yoshida, Masaru; Asano, Masaharu; Kaetsu, Isao

    1982-01-01

    The polymer microspheres containing drugs as drug delivery system were made by means of suspension-polymerization by radiation at low temperature by using glass-forming monomers which have stable supercooling properties and large polymerizability at low temperature. The particle distribution depended on the kind of monomer. It was found that the entrapping yield of drug in polymer microspheres increased with increasing viscosity of monomer and that the maximum value on the particle size distribution curve was also shifted to large particle diameter side. In the case of trimethylolpropane trimethacrylate monomer (43 cps), TMPT, the entrapping yield of drug reached 74% and the maximum value in particle size distribution curve appeared in the neighborhood of 105 to 210 mu m ranges. On the other hand, those values in neopentyl glycol dimethacrylate monomer (4 cps) were 12% in former and 44 -- 105 mu m in the latter. The release phenomenon of drugs from polymer microspheres was investigated. for example, the cumulative amount of mitomycin C (water soluble drug) released from TMPT polymer microsphere was about 90% after 30-day dissolution, while in the case of water-insoluble drug such as testosterone the amount of release was about 49% after 40-day dissolution. In all cases, the release rate is constant during the experimental period. Therefore, it was concluded that the release of drugs from polymer microspheres obtained in this study is possible over the long periods. (author)

  10. Microsphere estimates of blood flow: Methodological considerations

    International Nuclear Information System (INIS)

    von Ritter, C.; Hinder, R.A.; Womack, W.; Bauerfeind, P.; Fimmel, C.J.; Kvietys, P.R.; Granger, D.N.; Blum, A.L.

    1988-01-01

    The microsphere technique is a standard method for measuring blood flow in experimental animals. Sporadic reports have appeared outlining the limitations of this method. In this study the authors have systematically assessed the effect of blood withdrawals for reference sampling, microsphere numbers, and anesthesia on blood flow estimates using radioactive microspheres in dogs. Experiments were performed on 18 conscious and 12 anesthetized dogs. Four blood flow estimates were performed over 120 min using 1 x 10 6 microspheres each time. The effects of excessive numbers of microspheres pentobarbital sodium anesthesia, and replacement of volume loss for reference samples with dextran 70 were assessed. In both conscious and anesthetized dogs a progressive decrease in gastric mucosal blood flow and cardiac output was observed over 120 min. This was also observed in the pancreas in conscious dogs. The major factor responsible for these changes was the volume loss due to the reference sample withdrawals. Replacement of the withdrawn blood with dextran 70 led to stable blood flows to all organs. The injection of excessive numbers of microspheres did not modify hemodynamics to a greater extent than did the injection of 4 million microspheres. Anesthesia exerted no influence on blood flow other than raising coronary flow. The authors conclude that although blood flow to the gastric mucosa and the pancreas is sensitive to the minor hemodynamic changes associated with the microsphere technique, replacement of volume loss for reference samples ensures stable blood flow to all organs over a 120-min period

  11. Microsphere based improved sunscreen formulation of ethylhexyl methoxycinnamate.

    Science.gov (United States)

    Gogna, Deepak; Jain, Sunil K; Yadav, Awesh K; Agrawal, G P

    2007-04-01

    Polymethylmethacrylate (PMMA) microspheres of ethylhexyl methoxycinnamate (EHM) were prepared by emulsion solvent evaporation method to improve its photostability and effectiveness as sunscreening agent. Process parameters like stirring speed and aqueous polyvinyl alcohol (PVA) concentration were analyzed in order to optimize the formulations. Shape and surface morphology of the microspheres were examined using scanning electron microscopy. Particle size of the microspheres was determined using laser diffraction particle size analyzer. The PMMA microspheres of EHM were incorporated in water-removable cream base. The in vitro drug release of EHM in pH 7.4 was performed using dialysis membrane. Thin layer chromatography was performed to determine photostability of EHM inside the microspheres. The formulations were evaluated for sun protection factor (SPF) and minimum erythema dose (MED) in albino rats. Cream base formulation containing microspheres prepared using EHM:PMMA in ratio of 1:3 (C(3)) showed slowest drug (EHM) release and those prepared with EHM: PMMA in ratio of 1:1 showed fastest release. The cream base formulations containing EHM loaded microspheres had shown better SPF (more than 16.0) as compared to formulation C(d) that contained 3% free EHM as sunscreen agent and showed SPF 4.66. These studies revealed that the incorporation of EHM loaded PMMA microspheres into cream base had greatly increased the efficacy of sunscreen formulation approximately four times. Further, photostability was also shown to be improved in PMMA microspheres.

  12. Preparation and Characterization of Sugar Cane Wax Microspheres ...

    African Journals Online (AJOL)

    ... and characterize indomethacin (IM) microspheres prepared with sugar cane wax microsperes. Methods: Microspheres were prepared by melt-emulsified dispersion and cooling-induced solidification method. The microspheres were characterized by scanning electron microscopy (SEM) and differntial scanning calorimetry ...

  13. Preparation of mesoporous zirconia microspheres as inert matrix

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Ting [State Key Laboratory of New Ceramics and Fine Processing, Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing, 100084 (China); Wang, Chen; Lv, Jinlong [Beijing Key Laboratory of Fine Ceramics, Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing, 100084 (China); Liang, Tongxiang, E-mail: txliang@tsinghua.edu.cn [State Key Laboratory of New Ceramics and Fine Processing, Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing, 100084 (China)

    2016-12-01

    Mesoporous zirconia microspheres, with a diameter of 900 μm, were prepared as an inert accelerator driven system (ADS) transmutation element matrix by the sol-gel method. The purpose of mesopores is to improve the adsorption capacity of inert matrix fuel (IMF) for minor actinides. The study indicated that the mesoporous zirconia performance was improved after the microspheres were hydrothermally treated at 150 °C, the specific surface area increased from 28.29 m{sup 2}/g to 61.28 m{sup 2}/g, and hydrothermal treatment avoided the cracking of the microspheres. Pre-decomposition of the organics during the hydrothermal process stabilized the mesoporous structure. The average pore diameter of mesoporous microsphere was 14.3 nm. - Highlights: • Mesoporous zirconia microspheres with a diameter of 900 μm were prepared as ADS transmutation element inert matrix. • The mesoporous performance was improved after the microspheres were hydrothermally treated at 150 °C. • The specific surface area increased from 28.29 m{sup 2}/g to 61.28 m{sup 2}/g. • The hydrothermal treatment could avoid the cracking of the microspheres. • The specific surface area of mesoporous microsphere was 61.28 m{sup 2}/g and the average pore diameter was 14.3 nm.

  14. Insulin delivery through nasal route using thiolated microspheres.

    Science.gov (United States)

    Nema, Tarang; Jain, Ashish; Jain, Aviral; Shilpi, Satish; Gulbake, Arvind; Hurkat, Pooja; Jain, Sanjay K

    2013-01-01

    The aim of the present study was to investigate the potential of developed thiolated microspheres for insulin delivery through nasal route. In the present study, cysteine was immobilized on carbopol using EDAC. A total of 269.93 µmol free thiol groups per gram polymer were determined. The prepared nonthiolated and thiolated microspheres were studied for particle shape, size, drug content, swellability, mucoadhesion and in vitro insulin release. The thiolated microspheres exhibited higher mucoadhesion due to formation of covalent bonds via disulfide bridges with the mucus gel layer. Drug permeation through goat nasal mucosa of nonthiolated and thiolated microspheres were found as 52.62 ± 2.4% and 78.85 ± 3.1% in 6 h, respectively. Thiolated microspheres bearing insulin showed better reduction in blood glucose level (BGL) in comparison to nonthiolated microspheres as 31.23 ± 2.12% and 75.25 ± 0.93% blood glucose of initial BGL were observed at 6 h after nasal delivery of thiolated and nonthiolated microspheres in streptozotocin-induced diabetic rabbits.

  15. Current knowledge on biodegradable microspheres in drug delivery.

    Science.gov (United States)

    Prajapati, Vipul D; Jani, Girish K; Kapadia, Jinita R

    2015-08-01

    Biodegradable microspheres have gained popularity for delivering a wide variety of molecules via various routes. These types of products have been prepared using various natural and synthetic biodegradable polymers through suitable techniques for desired delivery of various challenging molecules. Selection of biodegradable polymers and technique play a key role in desired drug delivery. This review describes an overview of the fundamental knowledge and status of biodegradable microspheres in effective delivery of various molecules via desired routes with consideration of outlines of various compendial and non-compendial biodegradable polymers, formulation techniques and release mechanism of microspheres, patents and commercial biodegradable microspheres. There are various advantages of using biodegradable polymers including promise of development with different types of molecules. Biocompatibility, low dosage and reduced side effects are some reasons why usage biodegradable microspheres have gained in popularity. Selection of biodegradable polymers and formulation techniques to create microspheres is the biggest challenge in research. In the near future, biodegradable microspheres will become the eco-friendly product for drug delivery of various genes, hormones, proteins and peptides at specific site of body for desired periods of time.

  16. Optimization of preparation method for ketoprofen-loaded microspheres consisting polymeric blends using simplex lattice mixture design

    Energy Technology Data Exchange (ETDEWEB)

    Das, Sanjoy Kumar, E-mail: sanjoydasju@gmail.com; Khanam, Jasmina; Nanda, Arunabha

    2016-12-01

    In the present investigation, simplex lattice mixture design was applied for formulation development and optimization of a controlled release dosage form of ketoprofen microspheres consisting polymers like ethylcellulose and Eudragit{sup ®}RL 100; when those were formed by oil-in-oil emulsion solvent evaporation method. The investigation was carried out to observe the effects of polymer amount, stirring speed and emulsifier concentration (% w/w) on percentage yield, average particle size, drug entrapment efficiency and in vitro drug release in 8 h from the microspheres. Analysis of variance (ANOVA) was used to estimate the significance of the models. Based on the desirability function approach numerical optimization was carried out. Optimized formulation (KTF-O) showed close match between actual and predicted responses with desirability factor 0.811. No adverse reaction between drug and polymers were observed on the basis of Fourier transform infrared (FTIR) spectroscopy and Differential scanning calorimetric (DSC) analysis. Scanning electron microscopy (SEM) was carried out to show discreteness of microspheres (149.2 ± 1.25 μm) and their surface conditions during pre and post dissolution operations. The drug release pattern from KTF-O was best explained by Korsmeyer-Peppas and Higuchi models. The batch of optimized microspheres were found with maximum entrapment (~ 90%), minimum loss (~ 10%) and prolonged drug release for 8 h (91.25%) which may be considered as favourable criteria of controlled release dosage form. - Graphical abstract: Optimization of preparation method for ketoprofen-loaded microspheres consisting polymeric blends using simplex lattice mixture design. - Highlights: • Simplex lattice design was used to optimize ketoprofen-loaded microspheres. • Polymeric blend (Ethylcellulose and Eudragit® RL 100) was used. • Microspheres were prepared by oil-in-oil emulsion solvent evaporation method. • Optimized formulation depicted favourable

  17. Hydrogen transport and storage in engineered glass microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Rambach, G.D.

    1995-04-18

    New, high strength glass microspheres filled with pressurized hydrogen exhibit densities which make them attractive for bulk hydrogen storage and transport. The membrane tensile stress at failure for our engineered glass microspheres is about 150,000 psi, permitting a threefold increase in pressure limit and storage capacity above commercial microspheres, which have been studied a decade ago and have been shown to fail at membrane stresses of 50,000 psi. Our analysis relating glass microspheres for hydrogen transport with infrastructure and economics, indicate that pressurized microspheres can be economically competitive with other forms of bulk rail and truck transport such as pressurized tube transports and liquid hydrogen trailers.

  18. Evaluation of radiolabelled microspheres as digesta markers

    International Nuclear Information System (INIS)

    Young, B.A.; Turner, B.V.; Dixon, A.E.; Exley, D.M.; Young, S.B.; Abidin, Z.

    1991-01-01

    The suitability of microspheres as markers for measuring digesta kinetics in sheep was examined. Microspheres offer advantages of uniformity of size and density, and stability during passage through the gastrointestinal tract. They are commercially available labelled with the choice of one of eleven different radionuclides and can be easily measured in digesta and faecal material. Tests comparing several types of digesta markers gave different measures of kinetic parameters when the measurements were made concurrently in the same sheep. However, concurrent measurements derived from use of microspheres were consistent. Microspheres offer a new alternative for digestive studies. (author). 19 refs, 4 tabs

  19. Glass microspheres for brachytherapy

    International Nuclear Information System (INIS)

    Prado, Miguel O.; Prastalo, Simon; Blaumann, Herman; Longhino, Juan M.; Repetto Llamazares, A.H.V.

    2007-01-01

    We developed the capacity to produce glass microspheres containing in their structure one or more radioactive isotopes useful for brachytherapy. We studied the various facts related with their production: (Rare earth) alumino silicate glass making, glass characterization, microspheres production, nuclear activation through (n,γ) nuclear reactions, mechanical characterization before and after irradiation. Corrosion tests in simulated human plasma and mechanical properties characterization were done before and after irradiation. (author) [es

  20. Toxicity of inhaled 90Y in fused clay particles in beagle dogs. VI

    International Nuclear Information System (INIS)

    Hobbs, C.H.; Chiffelle, T.L.; Hahn, F.F.; Jones, R.K.; Mauderly, J.L.; McClellan, R.O.; Pickrell, J.A.

    1974-01-01

    Studies on the metabolism, dosimetry, and effects of inhaled 90 Y in fused clay in the Beagle dog are being continued to assess the consequences of inhalation of an energetic beta emitter that has a short effective half-life in the lung. A radiation dose pattern study in which 12 dogs were sacrificed in pairs at 0, 2, 4, 6, 8, and 12 days post-inhalation exposure has been completed. A longevity study in which 89 dogs have been exposed to 90 Y fused clay with initial lung burdens ranging from 80 to 5200 μCi/kg body weight and 12 control dogs were exposed to stable yttrium in fused clay is in progress. The 90 Y was retained in lung with a half-life similar to its physical half-life (64 hours) and with only small quantities translocated to tracheobronchial lymph nodes, skeleton, and liver. The infinite radiation doses to lung, tracheobronchial lymph nodes, skeleton, and liver for an initial lung burden of 100 μCi 90 Y/kg of body weight were estimated to be 1600, 170, 0.54, and 0.38 rads, respectively. Thirty-eight of 39 dogs with doses to lung from 9300 to 70,000 rads have died at 7.5 to 903 days post-exposure. The one surviving dog in this dose range has radiographic evidence of pulmonary fibrosis at 1316 days post-exposure. All the dogs that died had radiation pneumonitis. The dog that died at 903 days post-exposure with a dose to lung of 11,000 rads also had 2 small pulmonary adenomas. Fifty exposed dogs with doses to lung of 1300 to 7900 rads are surviving with no significant abnormalities at 1278 to 1834 days post-exposure and will be studied for the remainder of their lifespan. (U.S.)

  1. Investigation on the influence of metal ion impurities on the complexation behavior of generator produced {sup 90}Y with different bifunctional chelators

    Energy Technology Data Exchange (ETDEWEB)

    Pandey, Usha; Gamre, Naresh; Chakravarty, Rubel; Pillai, Maroor Raghavan Ambikalmajan; Dash, Ashutosh [Bhabha Atomic Research Centre, Trombay, Mumbai (India). Radiopharmaceuticals Div.

    2014-07-01

    While the {sup 90}Sr/{sup 90}Y generator is the exclusive source of obtaining 'no carrier added' {sup 90}Y for targeted therapy, the presence of trace metals in the radiolabeling solutions poses a serious challenge owing to their ability to diminish the {sup 90}Y complexation yields with bifunctional chelators (BFCs). p-SCN-Bn-PCTA is a novel ligand having faster complexation kinetics with a number of radiometals. In this work, a systematic investigation was performed to evaluate the chelating ability of p-SCN-Bn-PCTA for {sup 90}Y and the influence of trace metal ions on it's complexation with {sup 90}Y in comparison to p-SCN-Bn-DTPA and p-SCN-Bn-DOTA using {sup 90}YCl{sub 3} obtained from an electrochemical generator. Results from our study indicate that while p-SCN-Bn-PCTA gave very good radiolabeling yields with {sup 90}Y when the reaction was carried out by heating for few minutes, it was most sensitive to the presence of trace metals, especially Fe(III). An independent and useful observation is that p-SCN-Bn-PCTA could be considered as the ligand of choice for assessing the chemical purity of generator derived {sup 90}Y.

  2. Preparation of polystyrene microsphere with emulsion microencapsulation method

    International Nuclear Information System (INIS)

    Li Bo Zhang Lin; Zhang Zhganwen; You Dan; Wei Yun; Wang Chaoyang; Lin Bo; Shi Tao; Chu Qiaomei

    2003-01-01

    The preparation of hollow polystyrene microspheres that are used as inner shell of multi-shell plastic microspheres in the ICF experiments is focused on. The effects of surfactants, water-soluble polymer and electrolyte on the properties of resultant microspheres are studied. Based on these experiments, a fabricating procedure was established with which hollow microspheres were prepared with diameter about 150-3000 μm, wall thickness 0.8-15 μm and toughness Ra less than 4 nm. (authors)

  3. Somatostatin-based radiopeptide therapy with [{sup 177}Lu-DOTA]-TOC versus [{sup 90}Y-DOTA]-TOC in neuroendocrine tumours

    Energy Technology Data Exchange (ETDEWEB)

    Romer, A.; Seiler, D.; Brunner, P.; Ng, Q.K.T.; Mueller-Brand, J. [University Hospital Basel, Institute of Nuclear Medicine, Basel (Switzerland); Marincek, N.; Walter, M.A. [University Hospital Basel, Institute of Nuclear Medicine, Basel (Switzerland); University Hospital Bern, Institute of Nuclear Medicine, Bern (Switzerland); Koller, M.T. [University Hospital Basel, Basel Institute for Clinical Epidemiology and Biostatistics, Basel (Switzerland); Maecke, H.R. [University Hospital Basel, Division of Radiochemistry, Basel (Switzerland); Rochlitz, C. [University Hospital Basel, Department of Oncology, Basel (Switzerland); Briel, M. [University Hospital Bern, Institute of Nuclear Medicine, Bern (Switzerland); University Hospital Basel, Basel Institute for Clinical Epidemiology and Biostatistics, Basel (Switzerland); McMaster University, Department of Clinical Epidemiology and Biostatistics, Hamilton (Canada); Schindler, C. [University of Basel, Swiss Tropical and Public Health Institute, Basel (Switzerland)

    2014-02-15

    Somatostatin-based radiopeptide treatment is generally performed using the β-emitting radionuclides {sup 90}Y or {sup 177}Lu. The present study aimed at comparing benefits and harms of both therapeutic approaches. In a comparative cohort study, patients with advanced neuroendocrine tumours underwent repeated cycles of [{sup 90}Y-DOTA]-TOC or [{sup 177}Lu-DOTA]-TOC until progression of disease or permanent adverse events. Multivariable Cox regression and competing risks regression were employed to examine predictors of survival and adverse events for both treatment groups. Overall, 910 patients underwent 1,804 cycles of [{sup 90}Y-DOTA]-TOC and 141 patients underwent 259 cycles of [{sup 177}Lu-DOTA]-TOC. The median survival after [{sup 177}Lu-DOTA]-TOC and after [{sup 90}Y-DOTA]-TOC was comparable (45.5 months versus 35.9 months, hazard ratio 0.91, 95 % confidence interval 0.63-1.30, p = 0.49). Subgroup analyses revealed a significantly longer survival for [{sup 177}Lu-DOTA]-TOC over [{sup 90}Y-DOTA]-TOC in patients with low tumour uptake, solitary lesions and extra-hepatic lesions. The rate of severe transient haematotoxicities was lower after [{sup 177}Lu-DOTA]-TOC treatment (1.4 vs 10.1 %, p = 0.001), while the rate of severe permanent renal toxicities was similar in both treatment groups (9.2 vs 7.8 %, p = 0.32). The present results revealed no difference in median overall survival after [{sup 177}Lu-DOTA]-TOC and [{sup 90}Y-DOTA]-TOC. Furthermore, [{sup 177}Lu-DOTA]-TOC was less haematotoxic than [{sup 90}Y-DOTA]-TOC. (orig.)

  4. Preparation of alumina microspheres

    International Nuclear Information System (INIS)

    Santos, W.R. dos; Abrao, A.

    1980-01-01

    Inorganic exchangers are widely used for adsorption and column partition chromatography. The main difficulty of using commercial alumina (in powder) for column chromatography is related to its packing, and the operations through the column become diffcult and time-consuming; also it turns to be virtually impossible to use large dimension columns. In order to eliminate these problems, a process for the preparation of alumina micro-spheres was developed as an adaptation of a similar process used to prepare nuclear fuel microspheres (UO 2 , ThO 2 ). The flowsheet of this process is presented together with the analytical results of sphericity after calcination, granulometry, density and characterization by X-ray diffractometry. Solubility tests showed that the so-prepared microspheres are well resistant to strong acids and bases; retention tests showed their efficiency, mainly to copper. (C.L.B.) [pt

  5. Controlling silk fibroin microspheres via molecular weight distribution

    International Nuclear Information System (INIS)

    Zeng, Dong-Mei; Pan, Jue-Jing; Wang, Qun; Liu, Xin-Fang; Wang, Hui; Zhang, Ke-Qin

    2015-01-01

    Silk fibroin (SF) microspheres were produced by salting out SF solution via the addition of potassium phosphate buffer solution (K 2 HPO 4 –KH 2 PO 4 ). The morphology, size and polydispersity of SF microspheres were adjusted by changing the molecular weight (MW) distribution and concentration of SF, as well as the ionic strength and pH of the buffer solution. Changing the conditions under which the SF fiber dissolved in the Lithium Boride (LiBr) solution resulted in altering the MW distribution of SF solution. Under optimal salting-out conditions (ionic strength > 0.7 M and pH > 7) and using a smaller and narrower SF MW distribution, SF microspheres with smoother shapes and more uniform sizes were produced. Meanwhile, the size and polydispersity of the microspheres increased when the SF concentration was increased from 0.25 mg/mL to 20 mg/mL. The improved SF microspheres, obtained by altering the distribution of molecular weight, have potential in drug and gene delivery applications. - Highlights: • MW distribution was changed by applying different dissolving methods of SF fiber. • Smaller and narrower MW distribution improves the quality of SF microspheres. • Size and polydispersity of microspheres increase as SF concentration increases. • Improved SF microspheres have potential in drug and gene delivery applications

  6. Controlling silk fibroin microspheres via molecular weight distribution

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Dong-Mei; Pan, Jue-Jing; Wang, Qun; Liu, Xin-Fang; Wang, Hui [National Engineering Laboratory for Modern Silk, College for Textile and Clothing Engineering, Soochow University, Suzhou, Jiangsu 215123 (China); Zhang, Ke-Qin, E-mail: kqzhang@suda.edu.cn [National Engineering Laboratory for Modern Silk, College for Textile and Clothing Engineering, Soochow University, Suzhou, Jiangsu 215123 (China); Research Center of Cooperative Innovation for Functional Organic/Polymer Material Micro/Nanofabrication, Soochow University, Suzhou, Jiangsu 215123 (China)

    2015-05-01

    Silk fibroin (SF) microspheres were produced by salting out SF solution via the addition of potassium phosphate buffer solution (K{sub 2}HPO{sub 4}–KH{sub 2}PO{sub 4}). The morphology, size and polydispersity of SF microspheres were adjusted by changing the molecular weight (MW) distribution and concentration of SF, as well as the ionic strength and pH of the buffer solution. Changing the conditions under which the SF fiber dissolved in the Lithium Boride (LiBr) solution resulted in altering the MW distribution of SF solution. Under optimal salting-out conditions (ionic strength > 0.7 M and pH > 7) and using a smaller and narrower SF MW distribution, SF microspheres with smoother shapes and more uniform sizes were produced. Meanwhile, the size and polydispersity of the microspheres increased when the SF concentration was increased from 0.25 mg/mL to 20 mg/mL. The improved SF microspheres, obtained by altering the distribution of molecular weight, have potential in drug and gene delivery applications. - Highlights: • MW distribution was changed by applying different dissolving methods of SF fiber. • Smaller and narrower MW distribution improves the quality of SF microspheres. • Size and polydispersity of microspheres increase as SF concentration increases. • Improved SF microspheres have potential in drug and gene delivery applications.

  7. Antibacterial activity of ciprofloxacin-loaded zein microsphere films

    International Nuclear Information System (INIS)

    Fu Jianxi; Wang Huajie; Zhou Yanqing; Wang Jinye

    2009-01-01

    Our aim was to produce an antibiotic-emitting coating composed of zein microspheres for the prevention of bacterial infection on implanted devices. Ciprofloxacin-loaded zein microspheres were prepared using a phase separation procedure, with particle sizes between 0.5 and 2 μm. Drug encapsulation and drug loading varied with the amount of both zein and ciprofloxacin, and the highest encapsulation efficiency was 8.27% (2 mg/ml ciprofloxacin and 20 mg/ml zein; n = 3). A ciprofloxacin-loaded zein microsphere film (CF-MS film) was generated via solvent evaporation. Continuous drug release from a trypsin-degraded microsphere film was observed for up to 28 days. The liberation of ciprofloxacin from the trypsin-degraded film and the biodegradation of the microsphere film were highly correlated. Proliferation assay of the growth of human umbilical vein endothelial cells (HUVECs) by the MTT method showed that the microsphere film had no toxicity when compared with cells grown on Corning culture plates alone and plates with a zein film alone. Quantification of bacteria adhesion showed that adhesion on the microsphere film is significantly suppressed. In addition, according to the results of bacterial growth tests, ciprofloxacin-loaded microsphere films maintained antibacterial activity for more than 6 days. In contrast, a control medium containing a zein film allowed constant bacterial growth. These results indicate that CF-MS films might be useful as antibacterial films on implanted devices.

  8. Antibacterial activity of ciprofloxacin-loaded zein microsphere films

    Energy Technology Data Exchange (ETDEWEB)

    Fu Jianxi [Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 354 Fenglin Road, Shanghai 200032 (China); Henan Normal University, 46 East Construction Road, Xinxiang, Henan 453007 (China); Wang Huajie [College of Life Science and Biotechnology, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai 200030 (China); Zhou Yanqing [Henan Normal University, 46 East Construction Road, Xinxiang, Henan 453007 (China); Wang Jinye, E-mail: jywang@mail.sioc.ac.cn [Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 354 Fenglin Road, Shanghai 200032 (China); College of Life Science and Biotechnology, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai 200030 (China)

    2009-05-05

    Our aim was to produce an antibiotic-emitting coating composed of zein microspheres for the prevention of bacterial infection on implanted devices. Ciprofloxacin-loaded zein microspheres were prepared using a phase separation procedure, with particle sizes between 0.5 and 2 {mu}m. Drug encapsulation and drug loading varied with the amount of both zein and ciprofloxacin, and the highest encapsulation efficiency was 8.27% (2 mg/ml ciprofloxacin and 20 mg/ml zein; n = 3). A ciprofloxacin-loaded zein microsphere film (CF-MS film) was generated via solvent evaporation. Continuous drug release from a trypsin-degraded microsphere film was observed for up to 28 days. The liberation of ciprofloxacin from the trypsin-degraded film and the biodegradation of the microsphere film were highly correlated. Proliferation assay of the growth of human umbilical vein endothelial cells (HUVECs) by the MTT method showed that the microsphere film had no toxicity when compared with cells grown on Corning culture plates alone and plates with a zein film alone. Quantification of bacteria adhesion showed that adhesion on the microsphere film is significantly suppressed. In addition, according to the results of bacterial growth tests, ciprofloxacin-loaded microsphere films maintained antibacterial activity for more than 6 days. In contrast, a control medium containing a zein film allowed constant bacterial growth. These results indicate that CF-MS films might be useful as antibacterial films on implanted devices.

  9. U3O8 microspheres sintering kinetics

    International Nuclear Information System (INIS)

    Godoy, A.L.E.

    1986-01-01

    U 3 O 8 microspheres sintering kinetics was determined using a hot-stage optical microscopy apparatus, able to reach temperature up to 1350 0 C in controlled atmospheres. The sintered material had its microstructure analysed by optical and electron microscopy. The microspheres were characterized initialy utilizing X-ray diffractometry and thermogravimetry. The equation which describes the microspheres shrinkage in function of the time was obtained using finite difference analysis X-ray diffractometry indicated hexagonal structure for the microspheres main starting material, ammonium diuranate thermogravimetric analysis showed reduction of this material to U 3 O 8 at 600 0 C. Ceramography results showed 5 hours sintered microspheres grain sizes G vary with the temperature. Sintered U 3 O 8 micrographs compared with published results for UO 2 , indicate similar homogeneity microstructural characteristics and suggest the processed micorspheres to be potentially useful as nuclear fuels. (Author) [pt

  10. Preparation of UC0.07-0.10N0.90-0.93 spheres for TRISO coated fuel particles

    Science.gov (United States)

    Hunt, R. D.; Silva, C. M.; Lindemer, T. B.; Johnson, J. A.; Collins, J. L.

    2014-05-01

    The US Department of Energy is considering a new nuclear fuel that would be less susceptible to ruptures during a loss-of-coolant accident. The fuel would consist of tristructural isotropic coated particles with dense uranium nitride (UN) kernels with diameters of 650 or 800 μm. The objectives of this effort are to make uranium oxide microspheres with adequately dispersed carbon nanoparticles and to convert these microspheres into UN spheres, which could be then sintered into kernels. Recent improvements to the internal gelation process were successfully applied to the production of uranium gel spheres with different concentrations of carbon black. After the spheres were washed and dried, a simple two-step heat profile was used to produce porous microspheres with a chemical composition of UC0.07-0.10N0.90-0.93. The first step involved heating the microspheres to 2023 K in a vacuum, and in the second step, the microspheres were held at 1873 K for 6 h in flowing nitrogen.

  11. One-pot fabrication of Co{sub 3}O{sub 4} microspheres via hydrothermal method at low temperature for high capacity supercapacitor

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Chao; Zhang, Jinfeng [State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai 200240 (China); Deng, Yida, E-mail: yida.deng@tju.edu.cn [School of Material Science and Engineering, Tianjin University, Tianjin 300072 (China); Zhong, Cheng [School of Material Science and Engineering, Tianjin University, Tianjin 300072 (China); Liu, Lei [State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai 200240 (China); Hu, Wenbin [State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai 200240 (China); School of Material Science and Engineering, Tianjin University, Tianjin 300072 (China)

    2015-09-15

    Highlights: • Take full advantage of the easily oxidized feature of cobalt (II) complexes ammonia. • Low temperature method was applied with absence of subsequent calcination process. • The Co{sub 3}O{sub 4} microspheres possess extraordinary electrochemical properties. - Abstract: Co{sub 3}O{sub 4} microspheres were successfully produced with one-step low temperature hydrothermal method and their electrochemical properties have been investigated. By means of utilizing easily oxidized characteristic of cobalt complexes ammonia, the Co{sub 3}O{sub 4} microspheres were synthesized for the first time with an extremely low hydrothermal temperature (100 °C). In the absent case of surfactant, these Co{sub 3}O{sub 4} microspheres with a diameter of ca. 500 nm and smooth surface were prepared with the assistance of nitrate. Influences concerning about temperature and concentration of nitrate on morphology and size distribution were thoroughly discussed. Electrochemical characterization indicated that the Co{sub 3}O{sub 4} microspheres exhibited high specific capacitance of 850, 780, 700, 630 F/g at current densities of 1, 2, 4, 8 A/g, respectively. And after 1000 cycles, the devices with Co{sub 3}O{sub 4} microspheres showed high charge/discharge reversibility with an efficiency of 90.8% at a current density of 2 A/g.

  12. Radioembolization of Colorectal Liver Metastases: Indications, Technique, and Outcomes.

    Science.gov (United States)

    Boas, F Edward; Bodei, Lisa; Sofocleous, Constantinos T

    2017-09-01

    Liver metastases are a major cause of death from colorectal cancer. Intraarterial therapy options for colorectal liver metastases include chemoinfusion via a hepatic arterial pump or port, irinotecan-loaded drug-eluting beads, and radioembolization using 90 Y microspheres. Intraarterial therapy allows the delivery of a high dose of chemotherapy or radiation into liver tumors while minimizing the impact on liver parenchyma and avoiding systemic effects. Specificity in intraarterial therapy can be achieved both through preferential arterial flow to the tumor and through selective catheter positioning. In this review, we discuss indications, contraindications, preprocedure evaluation, activity prescription, follow-up, outcomes, and complications of radioembolization of colorectal liver metastases. Methods for preventing off-target embolization, increasing the specificity of microsphere delivery, and reducing the lung-shunt fraction are discussed. There are 2 types of 90 Y microspheres: resin and glass. Because glass microspheres have a higher activity per particle, they can deliver a particular radiation dose with fewer particles, likely reducing embolic effects. Glass microspheres thus may be more suitable when early stasis or reflux is a concern, in the setting of hepatocellular carcinoma with portal vein invasion, and for radiation segmentectomy. Because resin microspheres have a lower activity per particle, more particles are needed to deliver a particular radiation dose. Resin microspheres thus may be preferable for larger tumors and those with high arterial flow. In addition, resin microspheres have been approved by the U.S. Food and Drug Administration for colorectal liver metastases, whereas institutional review board approval is required before glass microspheres can be used under a compassionate-use or research protocol. Finally, radiation segmentectomy involves delivering a calculated lobar activity of 90 Y microspheres selectively to treat a tumor

  13. Dosimetry in radionuclide therapies with 90Y-conjugates. The IEO experience

    International Nuclear Information System (INIS)

    Cremonesi, M.; Ferrari, M.; Chinol, M.; Bartolomei, M.; Sacco, E.; Fiorenza, M.; Tosi, G.; Paganelli, G.; Stabin, M. G.

    2000-01-01

    The basis for successful radionuclide therapy is a high and stable uptake of the radiopharmaceutical in the target tissue along with low activity concentration in other normal organs. The contribution of dosimetry in radionuclide therapy is to predict before the treatment the absorbed doses in tumor and normal organs, to identify the critical organs, to minimize any possible toxicity and to evaluate the maximum tolerated dose. In this article is reported the experience concerning pharmacokinetics and dosimetry of two 90 Y-therapeutic protocols: 3-step pretargeting radioimmunotherapy (RIT) according to the biotin-avidin system and receptor mediated radionuclide therapy with the somatostatin analogue (DOTA-D-Phe 1 -Tyr 3 ) octreotide named DOTATOC. For the dosimetric analysis, analogous approaches for the two radiolabeled compounds due to the similar pharmacokinetic characteristics were adopted; the MIRD formalism was applied, taking into account both the physical and the biological characteristics of the radio conjugate and patients' metabolism. In order to determine biological clearance, serial blood samples and complete urine collection were obtained up to 48 hours after injection; to evaluate biodistribution, several whole body scans were acquired. Both therapies showed the advantageous characteristics of a fast blood clearance and a predominantly renal excretion of the radiopharmaceuticals thus lowering the irradiation of the total body. Although pharmacokinetic characteristics were similar, different critical organs were found for the two therapies: in particular, some considerations regarding red marrow, spleen and kidneys were required. The results of the studies indicate that high activities of 90 Y-biotin (3-step RIT) and 90 Y-DOTATOC can be administered with acceptable radiation doses to normal organs

  14. Evaluation of a pyrex glass shield for the dose reduction in extremities to manipulate a {sup 90} Sr- {sup 90} Y generator; Evaluacion de un blindaje de vidrio pyrex para la reduccion de las dosis en extremidades al manipular un generador de {sup 90} Sr- {sup 90} Y

    Energy Technology Data Exchange (ETDEWEB)

    Ayra P, F.E.; Xiques C, A.; Torres B, M.B. [Centro de Isotopos, Carretera La Rada, Km 3 1/2, Guanabacoa, La Habana (Cuba)]. e-mail: feayra@centis.edu.cu

    2006-07-01

    The production of Y-90 of high activity it specifies (free of payee) for their use in radioimmunotherapy uses the Strontium 90 as isotope source. Depending on the method employee for the separation of both isotopes several types of generators are described in different bibliographies. The column generator used in the facilities of the Center of Isotopes requires of a frequent manipulation causing significant dose in the skin of the extremities due to the exhibition to the radiation beta of high energy. The properties of the shieldings for this radiation type have been well studied Y they consist in several publications. To be in correspondence with requirements of radiological protection in the Cuban legislation, the column was covered with a tube of glass pyrex of 5 mm of thickness and it was monitored the exposure with an ionization chamber. At the own time, the shielding using the Monte Carlo method was evaluated. It was used the MCNP 4C code to simulate the absorption of the beta particles generated in the process of disintegration of the Sr-90 and Y-90 in the glass shielding. The column generator and the fluence of beta particles were modeled in different points inside the shielding to determine if the experimentally measured values correspond to electrons that were not absorbed or to the weak stopping radiation generated in the glass due to the deceleration of these particles. A cylinder of 4 mm of diameter simulates the source (it dilutes) and a tube of walls of 6 mm of thickness simulates the shielding more the wall of the column around the generator. This it was divided in cells of 1 mm of thickness and the energy deposited in them was evaluated. The results show that all the electrons generated in the source are absorbed in the shielding and the exposure rates decrease in more of 78 times using the 5 mm of pyrex glass. The doses in extremities to the operators of the generator don't surpass the 70 mSv by year that is the dose restriction imposed in

  15. Country report: Brazil. Development of Radiopharmaceuticals Based on {sup 188}Re and {sup 90}Y for Radionuclide Therapy at IPEN-CNEN/SP

    Energy Technology Data Exchange (ETDEWEB)

    Osso, Jr., J. A.; Barrio, G.; Dias, C. R.B.R.; Brambilla, T. P.; Dantas, D. M.; Suzuki, K. N.; Barboza, M. F.S.; Bortoleti, E.; Fukumori, N. T.; Mengatti, J. [Radiopharmacy Center – Institute of Energetic and Nuclear Research – IPE N-CNEN/SP, São Paulo – Brazil (Brazil)

    2010-07-01

    The overall objective of this CRP is to develop radiopharmaceuticals for targeted therapy using {sup 188}Re and {sup 90}Y and to study the performance of generators with long lived parent radionuclides as well as to validate the QC control procedures for estimating the purity of generator eluents. The CRP is expected to enhance the capability in production of {sup 90}Y and {sup 188}Re radiopharmaceuticals to meet the increasing demand of therapeutic products for clinical applications, in particular in Brazil. In this period efforts were made towards the assembling of {sup 90}Sr-{sup 90}Y generators, quality control of {sup 90}Y, the labelling of DMSA(V) and anti-CD20 with {sup 188}Re and the labelling of Hydroxiapatite(HA) with {sup 90}Y. (author)

  16. Peptide receptor radionuclide therapy with {sup 90}Y-DOTATOC in recurrent meningioma

    Energy Technology Data Exchange (ETDEWEB)

    Bartolomei, Mirco; Bodei, Lisa; De Cicco, Concetta; Grana, Chiara Maria; Baio, Silvia Melania; Arico, Demetrio; Paganelli, Giovanni [European Institute of Oncology, Division of Nuclear Medicine, Milan (Italy); Cremonesi, Marta [European Institute of Oncology, Division of Medical Physics, Milan (Italy); Botteri, Edoardo [European Institute of Oncology, Division of Epidemiology and Biostatistics, Milan (Italy); Sansovini, Maddalena [Istituto Scientifico Romagnolo per lo Studio e la Cura dei Tumori (I.R.S.T.), Radiometabolic Medicine Division, Meldola (Italy)

    2009-09-15

    Meningiomas are generally benign and in most cases surgery is curative. However, for high-grade histotypes or partially resected tumours, recurrence is fairly common. External beam radiation therapy (EBRT) is usually given in such cases but is not always effective. We assessed peptide receptor radionuclide therapy (PRRT) using {sup 90}Y-DOTATOC in a group of patients with meningioma recurring after standard treatments in all of whom somatostatin receptors were strongly expressed on meningioma cell surfaces. Twenty-nine patients with scintigraphically proven somatostatin subtype 2 receptor-positive meningiomas were enrolled: 14 had benign (grade I), 9 had atypical (grade II) and 6 had malignant (grade III) disease. Patients received intravenous {sup 90}Y-DOTATOC for 2-6 cycles for a cumulative dose in the range of 5-15 GBq. Clinical and neuroradiological evaluations were performed at baseline, during and after PRRT. The treatment was well tolerated in all patients. MRI 3 months after treatment completion showed disease stabilization in 19 of 29 patients (66%) and progressive disease in the remaining 10 (34%). Better results were obtained in patients with grade I meningioma than in those with grade II-III, with median time to progression (from beginning PRRT) of 61 months in the low-grade group and 13 months in the high-grade group. PRRT with {sup 90}Y-DOTATOC can interfere with the growth of meningiomas. The adjuvant role of this treatment, soon after surgery, especially in atypical and malignant histotypes, deserves further investigation. (orig.)

  17. Large-scale purification of {sup 90}Sr from nuclear waste materials for production of {sup 90}Y, a therapeutic medical radioisotope

    Energy Technology Data Exchange (ETDEWEB)

    Wester, D.W.; Steele, R.T.; Rinehart, D.E.; DesChane, J.R.; Carson, K.J.; Rapko, B.M.; Tenforde, T.S. E-mail: tenforde@ncrp.com

    2003-07-01

    A major limitation on the supply of the short-lived medical isotope {sup 90}Y (t{sub 1/2}=64 h) is the available quantity of highly purified {sup 90}Sr generator material. A radiochemical production campaign was therefore undertaken to purify 1500 Ci of {sup 90}Sr that had been isolated from fission waste materials. A series of alkaline precipitation steps removed all detectable traces of {sup 137}Cs, alpha emitters, and uranium and transuranic elements. Technical obstacles such as the buildup of gas pressure generated upon mixing large quantities of acid with solid {sup 90}Sr carbonate were overcome through safety features incorporated into the custom-built equipment used for {sup 90}Sr purification. Methods are described for analyzing the chemical and radiochemical purity of the final product and for accurately determining by gravimetry the quantities of {sup 90}Sr immobilized on stainless steel filters for future use.

  18. Country report: Pakistan. Second Research Co-ordination Meeting on Development of Radiopharmaceuticals Based on 188Re and 90Y for Radionuclide Therapy, 22-26 March 2010, Vienna

    International Nuclear Information System (INIS)

    Mansur, M.S.; Mushtaq, A.

    2010-01-01

    Various experiments were carried out for the separation of 90 Y from 90 Sr using colloid formation behavior of 90 Y in basic pH range. When the acidic solution of 90 Sr/ 90 Y was treated with NaOH and passed through a small glass wool column, more than 95% 90 Y was retained on glass wool, which was further washed with 0.1 M NaOH. The 90 Y was extracted in 1 M HCl. Radionuclidic purity was determined by half life measurement. The contamination of parent was less than 0.0001%. Similarly when the colloid was passed through membrane filter more than 95% 90 Y was retained which was recovered by 1 M HCl. The contamination of 90 Sr was less than 0.0001%. The stock solution of 90 Sr/ 90 Y in NH 4 OH/NaOH was again passed through Millipore filter paper or glass wool after one week. The retention of 90Y was insignificant. The equilibrium mixture of 90 Sr/ 90 Y was acidified with HCl and again precipitated with addition of NH 4 OH or NaOH. The basic solution was passed through the Millipore filter or glass wool. More than 90% activity of 90 Y was retained, which was finally extracted in 1 M HCl It was concluded that for recovery of 90 Y from 90 Sr by colloid formation, the acidic solution of 90 Sr/ 90 Y shall be freshly precipitated by NH 4 OH or NaOH. It was also observed that the adsorption of 90 Y was quite high when the 90 Sr solution was left in a glass vial for the growth of 90 Y. However it can be easily extracted after keeping it in boiling water bath for few minutes. The separated 90 Y via colloid formation was used for the labeling of EDTMP. Labeling efficiency of 90 Y-EDTMP was more than 98%

  19. Low pressure gas filling of laser fusion microspheres

    International Nuclear Information System (INIS)

    Koo, J.C.; Dressler, J.L.; Hendricks, C.D.

    1979-01-01

    In our laser fusion microsphere production, large, thin gel-microspheres are formed before the chemicals are fused into glass. In this transient stage,, the gel-microspheres are found to be highly permeable to argon and many other inert gases. When the gel transforms to glass, the argon gas, for example, is trapped within to form argon filled, fusion target quality, glass microspheres. On the average, the partial pressure of the argon fills attained in this process is around 2 x 10 4 Pa at room temperature

  20. Hollow porous-wall glass microspheres for hydrogen storage

    Science.gov (United States)

    Heung, Leung K.; Schumacher, Ray F.; Wicks, George G.

    2010-02-23

    A porous wall hollow glass microsphere is provided having a diameter range of between 1 to 200 microns, a density of between 1.0 to 2.0 gm/cc, a porous-wall structure having wall openings defining an average pore size of between 10 to 1000 angstroms, and which contains therein a hydrogen storage material. The porous-wall structure facilitates the introduction of a hydrogen storage material into the interior of the porous wall hollow glass microsphere. In this manner, the resulting hollow glass microsphere can provide a membrane for the selective transport of hydrogen through the porous walls of the microsphere, the small pore size preventing gaseous or liquid contaminants from entering the interior of the hollow glass microsphere.

  1. TU-FG-201-12: Designing a Risk-Based Quality Assurance Program for a Newly Implemented Y-90 Microspheres Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Vile, D; Zhang, L; Cuttino, L; Kim, S; Palta, J [Virginia Commonwealth University, Richmond, VA (United States)

    2016-06-15

    Purpose: To create a quality assurance program based upon a risk-based assessment of a newly implemented SirSpheres Y-90 procedure. Methods: A process map was created for a newly implemented SirSpheres procedure at a community hospital. The process map documented each step of this collaborative procedure, as well as the roles and responsibilities of each member. From the process map, different potential failure modes were determined as well as any current controls in place. From this list, a full failure mode and effects analysis (FMEA) was performed by grading each failure mode’s likelihood of occurrence, likelihood of detection, and potential severity. These numbers were then multiplied to compute the risk priority number (RPN) for each potential failure mode. Failure modes were then ranked based on their RPN. Additional controls were then added, with failure modes corresponding to the highest RPNs taking priority. Results: A process map was created that succinctly outlined each step in the SirSpheres procedure in its current implementation. From this, 72 potential failure modes were identified and ranked according to their associated RPN. Quality assurance controls and safety barriers were then added for failure modes associated with the highest risk being addressed first. Conclusion: A quality assurance program was created from a risk-based assessment of the SirSpheres process. Process mapping and FMEA were effective in identifying potential high-risk failure modes for this new procedure, which were prioritized for new quality assurance controls. TG 100 recommends the fault tree analysis methodology to design a comprehensive and effective QC/QM program, yet we found that by simply introducing additional safety barriers to address high RPN failure modes makes the whole process simpler and safer.

  2. TU-FG-201-12: Designing a Risk-Based Quality Assurance Program for a Newly Implemented Y-90 Microspheres Procedure

    International Nuclear Information System (INIS)

    Vile, D; Zhang, L; Cuttino, L; Kim, S; Palta, J

    2016-01-01

    Purpose: To create a quality assurance program based upon a risk-based assessment of a newly implemented SirSpheres Y-90 procedure. Methods: A process map was created for a newly implemented SirSpheres procedure at a community hospital. The process map documented each step of this collaborative procedure, as well as the roles and responsibilities of each member. From the process map, different potential failure modes were determined as well as any current controls in place. From this list, a full failure mode and effects analysis (FMEA) was performed by grading each failure mode’s likelihood of occurrence, likelihood of detection, and potential severity. These numbers were then multiplied to compute the risk priority number (RPN) for each potential failure mode. Failure modes were then ranked based on their RPN. Additional controls were then added, with failure modes corresponding to the highest RPNs taking priority. Results: A process map was created that succinctly outlined each step in the SirSpheres procedure in its current implementation. From this, 72 potential failure modes were identified and ranked according to their associated RPN. Quality assurance controls and safety barriers were then added for failure modes associated with the highest risk being addressed first. Conclusion: A quality assurance program was created from a risk-based assessment of the SirSpheres process. Process mapping and FMEA were effective in identifying potential high-risk failure modes for this new procedure, which were prioritized for new quality assurance controls. TG 100 recommends the fault tree analysis methodology to design a comprehensive and effective QC/QM program, yet we found that by simply introducing additional safety barriers to address high RPN failure modes makes the whole process simpler and safer.

  3. Encapsulated PDMS microspheres with reactive handles

    DEFF Research Database (Denmark)

    Gonzalez, Lidia; Ma, Baoguang; Li, Li

    2014-01-01

    , cured PDMS microspheres are coated with poly(methyl methacrylate) using a chemical process (solvent evaporation technique). Three solvents are used in three different experiments: dichloromethane, tetrahydrofuran, and acetone. The composition and morphology of the cured PDMS microspheres and PMMA coated...

  4. Microencapsulation and microspheres for food applications

    NARCIS (Netherlands)

    Sagis, L.M.C.

    2015-01-01

    This book provides an update on the latest developments, challenges, and opportunities in the highly expanding field of microencapsulation and microspheres for food applications, examining the various types of microspheres and microcapsules essential to those who need to develop stable and

  5. Dosimetry analysis of distributions radials dose profiles of {sup 90}Sr + {sup 90}Y beta therapy applicators using the MCNP-4C code and radio chromium films; Analise dosimetrica de perfis de distribuicoes radias de doses relativas de um aplicador de betaterapia de {sup 90}Sr + {sup 90}Y utilizando o codigo MCNP-4C e filmes radiocromicos

    Energy Technology Data Exchange (ETDEWEB)

    Coelho, Talita S.; Yoriyaz, Helio [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Fernandes, Marco A.R., E-mail: tasallesc@gmail.co [UNESP, Botucatu, SP (Brazil). Faculdade de Medicina. Servico de Radioterapia; Louzada, Mario J.Q. [UNESP, Aracatuba, SP (Brazil). Curso de Medicina Veterinaria

    2011-07-01

    Although they are no longer manufactured, the applicators of {sup 90}Sr + {sup 90}Y acquired in the decades of 1990 are still in use, by having half-life of 28.5 years. These applicators have calibration certificate given by their manufacturers, where few have been re calibrated. Thus it becomes necessary to accomplish thorough dosimetry of these applicators. This paper presents a dosimetric analysis distribution radial dose profiles for emitted by an {sup 90}Sr + {sup 90}Y beta therapy applicator, using the MCNP-4C code to simulate the distribution radial dose profiles and radio chromium films to get them experimentally . The results with the simulated values were compared with the results of experimental measurements, where both curves show similar behavior, which may validate the use of MCNP-4C and radio chromium films for this type of dosimetry. (author)

  6. Dosimetry analysis of distribution radial dose profiles of {sup 90}Sr + {sup 90}Y beta therapy applicators using the MCNP-4C code and radio chromium films; Analise dosimetrica de perfis de distribuicoes radiais de doses relativas de um aplicador de betaterapia de {sup 90}Sr + {sup 90}Y utilizando o codigo MCNP-4C e filmes radiocromicos

    Energy Technology Data Exchange (ETDEWEB)

    Coelho, T.S.; Yoriyaz, H. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Fernandes, M.A.R. [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Fac. de Medicina. Servico de Radioterapia; Louzada, M.J.Q. [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Aracatuba, SP (Brazil). Curso de Medicina Veterinaria

    2010-07-01

    Although they are no longer manufactured, the applicators of {sup 90}Sr +{sup 90}Y acquired in the decades of 1990 are still in use, by having half-life of 28.5 years. These applicators have calibration certificate given by their manufacturers, where few have been recalibrated. Thus it becomes necessary to accomplish thorough dosimetry of these applicators. This paper presents a dosimetric analysis distribution radial dose profiles for emitted by an {sup 90}Sr+{sup 90}Y beta therapy applicator, using the MCNP-4C code to simulate the distribution radial dose profiles and radiochromium films to get them experimentally . The results with the simulated values were compared with the results of experimental measurements, where both curves show similar behavior, which may validate the use of MCNP-4C and radiochromium films for this type of dosimetry. (author)

  7. Studying on process for labeling of EDTMP with 90Y using for bone pain palliation

    International Nuclear Information System (INIS)

    Pham Ngoc Dien; Duong Van Dong; Dang Ho Hong Quang; Nguyen Thanh Binh; Bui Van Cuong; Nguyen Dang Khoa; Nguyen Thi Thu; Mai Phuoc Tho; Vo Cam Hoa

    2013-01-01

    This Study describes the method for preparation of labelling compound Ethylene diamine tetramethylene phosphonic acid (EDTMP) with 90 Y. Malignant cancer is one of the most important resulting in human death. Bone metastases in nearly 25% of all cancer patients; so it is useful to develop radiopharmaceuticals for the treatment of bone cancer. Yttrium-90 is high energy (2.3 MeV) beta emitter required with a physical haft life of 2.7 days which has limited bone-seeking properties. Its physical properties make it ideal for therapeutic application, the most energetic beta emission being able to penetrate to 1 cm from the site of deposition in soft tissue with an average range of approximately 4 mm. Theoretically, therefore, it can penetrate all marrow spaces in normal trabecular bone and conceivably even to the centre of large tumours where bone destruction may be extensive. Specific deposition of 90 Y into the skeleton demands its delivery in a chemical form with affinity for bone mineral alone. Compounds with these properties are the phosphonate analogues of polyaminocarboxylic acids, and one in particular EDTMP (ethylen diamine tetra methylene phosphonate) has already been used to target 153 Sm to bone mineral with success. Because of chemical similarities between 90 Y and the rare earths, EDTMP should form stable complexes with 90 Y and carry it specifically to the bone with comparable efficiency. Skeletal uptake of β - emitting radionuclides may be used for bone pain palliation or myeloablation. The physical characteristics of the β - particles required for the two conditions are, however, different, that is, higher energies are favorable for destruction of bone marrow. (author)

  8. The somatostatin receptor-targeted radiotherapeutic [{sup 90}Y-DOTA-dPhe{sup 1},Tyr{sup 3}]octreotide ({sup 90}Y-SMT 487) eradicates experimental rat pancreatic CA 20948 tumours

    Energy Technology Data Exchange (ETDEWEB)

    Stolz, B.; Weckbecker, G.; Smith-Jones, P.M.; Albert, R.; Raulf, F.; Bruns, C. [Novartis Pharma AG, Basel (Switzerland)

    1998-07-01

    Somatostatin receptor-expressing tumours are potential targets for therapy with radiolabelled somatostatin analogues. We have synthesized a number of such analogues in the past and identified [DOTA-dPhe{sup 1}, Tyr{sup 3}]octreotide (SMT 487) as the most promising candidate molecule because of its advantageous properties in cellular and in vivo tumour models. In the current paper we describe the radiotherapeutic effect of yttrium-90 labelled SMT 487 in Lewis rats bearing the somatostatin receptor-positive rat pancreatic tumour CA 20948. SMT 487 binds with nanomolar affinity to both the human and the rat somatostatin receptor subtype 2 (sst{sub 2}) (human sst{sub 2} IC{sub 50}=0.9 nM, rat sst{sub 2} IC{sub 50}=0.5 nM). In vivo, {sup 90}Y-SMT 487 distributed rapidly to the sst{sub 2} expressing CA 20948 rat pancreatic tumour, with a tumour-to-blood ratio of 49.15 at 24 h post injection. A single intravenous administration of 10 mCi/kg {sup 90}Y-SMT 487 resulted in a complete remission of the tumours in five out of seven CA 20948 tumour-bearing Lewis rats. No regrowth of the tumours occurred 8 months post injection. Control animals that were treated with 30 {mu}g/kg of unlabelled SMT 487 had to be sacrificed 10 days post injection due to excessive growth or necrotic areas on the tumour surface. Upon re-inoculation of tumour cells into those rats that had shown complete remission, the tumours disappeared after 3-4 weeks of moderate growth without any further treatment. The present study shows for the first time the curative potential of {sup 90}Y-SMT 487-based radiotherapy for somatostatin receptor-expressing tumours. Clinical phase I studies with yttrium-labelled SMT 487 have started in September 1997. (orig.) With 4 figs., 2 tabs., 29 refs.

  9. A reproducible accelerated in vitro release testing method for PLGA microspheres.

    Science.gov (United States)

    Shen, Jie; Lee, Kyulim; Choi, Stephanie; Qu, Wen; Wang, Yan; Burgess, Diane J

    2016-02-10

    The objective of the present study was to develop a discriminatory and reproducible accelerated in vitro release method for long-acting PLGA microspheres with inner structure/porosity differences. Risperidone was chosen as a model drug. Qualitatively and quantitatively equivalent PLGA microspheres with different inner structure/porosity were obtained using different manufacturing processes. Physicochemical properties as well as degradation profiles of the prepared microspheres were investigated. Furthermore, in vitro release testing of the prepared risperidone microspheres was performed using the most common in vitro release methods (i.e., sample-and-separate and flow through) for this type of product. The obtained compositionally equivalent risperidone microspheres had similar drug loading but different inner structure/porosity. When microsphere particle size appeared similar, porous risperidone microspheres showed faster microsphere degradation and drug release compared with less porous microspheres. Both in vitro release methods investigated were able to differentiate risperidone microsphere formulations with differences in porosity under real-time (37 °C) and accelerated (45 °C) testing conditions. Notably, only the accelerated USP apparatus 4 method showed good reproducibility for highly porous risperidone microspheres. These results indicated that the accelerated USP apparatus 4 method is an appropriate fast quality control tool for long-acting PLGA microspheres (even with porous structures). Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Encapsulation of naproxen in lipid-based matrix microspheres: characterization and release kinetics.

    Science.gov (United States)

    Bhoyar, P K; Morani, D O; Biyani, D M; Umekar, M J; Mahure, J G; Amgaonkar, Y M

    2011-04-01

    The objective of this study was to microencapsulate the anti-inflammatory drug (naproxen) to provide controlled release and minimizing or eliminating local side effect by avoiding the drug release in the upper gastrointestinal track. Naproxen was microencapsulated with lipid-like carnauba wax, hydrogenated castor oil using modified melt dispersion (modified congealable disperse phase encapsulation) technique. Effect of various formulation and process variables such as drug-lipid ratio, concentration of modifier, concentration of dispersant, stirring speed, stirring time, temperature of external phase, on evaluatory parameters such as size, entrapment efficiency, and in vitro release of naproxen were studied. The microspheres were characterized for particle size, scanning electron microscopy (SEM), FT-IR spectroscopy, drug entrapment efficiency, in vitro release studies, for in vitro release kinetics. The shape of microspheres was found to be spherical by SEM. The drug entrapment efficiency of various batches of microspheres was found to be ranging from 60 to 90 %w/w. In vitro drug release studies were carried out up to 24 h in pH 7.4 phosphate buffer showing 50-65% drug release. In vitro drug release from all the batches showed better fitting with the Korsmeyer-Peppas model, indicating the possible mechanism of drug release to be by diffusion and erosion of the lipid matrix.

  11. Determination of Ideal Broth Formulations Needed to Prepare Hydrous Cerium Oxide Microspheres via the Internal Gelation Process

    Energy Technology Data Exchange (ETDEWEB)

    Collins, Jack Lee [ORNL; Chi, Anthony [ORNL

    2009-02-01

    A simple test tube methodology was used to determine optimum process parameters for preparing hydrous cerium oxide microspheres via the internal gelation process.1 Broth formulations of cerium ammonium nitrate [(NH4)2Ce(NO3)6], hexamethylenetetramine, and urea were found that can be used to prepare hydrous cerium oxide gel spheres in the temperature range of 60 to 90 C. A few gel-forming runs were made in which microspheres were prepared with some of these formulations to be able to equate the test-tube gelation times to actual gelation times. These preparations confirmed that the test-tube methodology is reliable for determining the ideal broth formulations.

  12. Response, survival, and long-term toxicity after therapy with the radiolabeled somatostatin analogue [90Y-DOTA]-TOC in metastasized neuroendocrine cancers.

    Science.gov (United States)

    Imhof, Anna; Brunner, Philippe; Marincek, Nicolas; Briel, Matthias; Schindler, Christian; Rasch, Helmut; Mäcke, Helmut R; Rochlitz, Christoph; Müller-Brand, Jan; Walter, Martin A

    2011-06-10

    To investigate response, survival, and safety profile of the somatostatin-based radiopeptide (90)yttrium-labeled tetraazacyclododecane-tetraacetic acid modified Tyr-octreotide ([(90)Y-DOTA]-TOC) in neuroendocrine cancers. In a clinical phase II single-center open-label trial, patients with neuroendocrine cancers were treated with repeated cycles of [(90)Y-DOTA]-TOC. Each cycle consisted of a single intravenous injection of 3.7GBq/m(2) body-surface [(90)Y-DOTA]-TOC. Additional cycles were withheld in case of tumor progression and/or permanent toxicity. Overall, 1,109 patients received 2,472 cycles of [(90)Y-DOTA]-TOC (median, two; range, one to 10 cycles per patient). Of the 1,109 patients, 378 (34.1%) experienced morphologic response; 172 (15.5%), biochemical response; and 329 (29.7%), clinical response. During a median follow-up of 23 months, 491 patients (44.3%) died. Longer survival was correlated with each: morphologic (hazard ratio [HR], 0.46; 95% CI, 0.38 to 0.56; median survival, 44.7 v 18.3 months; P TOC treatment in a large cohort. Response to [(90)Y-DOTA]-TOC is associated with longer survival. Somatostatin receptor imaging is predictive for both survival after [(90)Y-DOTA]-TOC treatment and occurrence of renal toxicity.

  13. Magnetic poly(glycidyl methacrylate) microspheres for protein capture.

    Science.gov (United States)

    Koubková, Jana; Müller, Petr; Hlídková, Helena; Plichta, Zdeněk; Proks, Vladimír; Vojtěšek, Bořivoj; Horák, Daniel

    2014-09-25

    The efficient isolation and concentration of protein antigens from complex biological samples is a critical step in several analytical methods, such as mass spectrometry, flow cytometry and immunochemistry. These techniques take advantage of magnetic microspheres as immunosorbents. The focus of this study was on the development of new superparamagnetic polymer microspheres for the specific isolation of the tumor suppressor protein p53. Monodisperse macroporous poly(glycidyl methacrylate) (PGMA) microspheres measuring approximately 5 μm and containing carboxyl groups were prepared by multistep swelling polymerization of glycidyl methacrylate (GMA), 2-[(methoxycarbonyl)methoxy]ethyl methacrylate (MCMEMA) and ethylene dimethylacrylate (EDMA) as a crosslinker in the presence of cyclohexyl acetate as a porogen. To render the microspheres magnetic, iron oxide was precipitated within their pores; the Fe content in the particles received ∼18 wt%. Nonspecific interactions between the magnetic particles and biological media were minimized by coating the microspheres with poly(ethylene glycol) (PEG) terminated by carboxyl groups. The carboxyl groups of the magnetic PGMA microspheres were conjugated with primary amino groups of mouse monoclonal DO-1 antibody using conventional carbodiimide chemistry. The efficiency of protein p53 capture and the degree of nonspecific adsorption on neat and PEG-coated magnetic microspheres were determined by western blot analysis. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Dental pulp stem cells immobilized in alginate microspheres for applications in bone tissue engineering.

    Science.gov (United States)

    Kanafi, M M; Ramesh, A; Gupta, P K; Bhonde, R R

    2014-07-01

    To immobilize dental pulp stem cells (DPSC) in alginate microspheres and to determine cell viability, proliferation, stem cell characteristics and osteogenic potential of the immobilized DPSCs. Human DPSCs isolated from the dental pulp were immobilized in 1% w/v alginate microspheres. Viability and proliferation of immobilized DPSCs were determined by trypan blue and MTT assay, respectively. Stem cell characteristics of DPSCs post immobilization were verified by labelling the cells with CD73 and CD90. Osteogenic potential of immobilized DPSCs was assessed by the presence of osteocalcin. Alizarin red staining and O-cresolphthalein complexone method confirmed and quantified calcium deposition. A final reverse transcriptase PCR evaluated the expression of osteogenic markers - ALP, Runx-2 and OCN. More than 80% of immobilized DPSCs were viable throughout the 3-week study. Proliferation appeared controlled and consistent unlike DPSCs in the control group. Presence of CD73 and CD90 markers confirmed the stem cell nature of immobilized DPSCs. The presence of osteocalcin, an osteoblastic marker, was confirmed in the microspheres on day 21. Mineralization assays showed high calcium deposition indicating elevated osteogenic potential of immobilized DPSCs. Osteogenic genes- ALP, Runx-2 and OCN were also upregulated in immobilized DPSCs. Surprisingly, immobilized DPSCs in the control group cultured in conventional stem cell media showed upregulation of osteogenic genes and expressed osteocalcin. Dental pulp stem cells immobilized in alginate hydrogels exhibit enhanced osteogenic potential while maintaining high cell viability both of which are fundamental for bone tissue regeneration. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  15. Radioembolization with 90Y Microspheres: Angiographic and Technical Considerations

    International Nuclear Information System (INIS)

    Lewandowski, Robert J.; Sato, Kent T.; Atassi, Bassel; Ryu, Robert K.; Nemcek, Albert A.; Kulik, Laura; Geschwind, Jean-Francois; Murthy, Ravi; Rilling, William; Liu, David; Bester, Lourens; Bilbao, Jose Ignacio; Kennedy, Andrew S.; Omary, Reed A.; Salem, Riad

    2007-01-01

    The anatomy of the mesenteric system and the hepatic arterial bed has been demonstrated to have a high degree of variation. This is important when considering pre-surgical planning, catheterization, and trans-arterial hepatic therapies. Although anatomical variants have been well described, the characterization and understanding of regional hepatic perfusion in the context of radioembolization have not been studied with great depth. The purpose of this review is to provide a thorough discussion and detailed presentation of the angiographic and technical aspects of radioembolization. Normal vascular anatomy, commonly encountered variants, and factors involved in changes to regional perfusion in the presence of liver tumors are discussed. Furthermore, the principles described here apply to all liver-directed transarterial therapies

  16. Does 99mTc MAA study accurately predict the Hepatopulmonary shunt fraction of 90Y theraspheres?

    International Nuclear Information System (INIS)

    Jha, Ashish; Zade, A.; Monteiro, P.; Shah, S.; Purandare, N.C.; Rangarajan, V.; Kulkarni, S.; Kulkarni, A.; Shetty, Nitin

    2010-01-01

    Full text: Transarterial-radioembolisation (TARE) is FDA approved therapeutic option for primary and metastatic liver malignancy when patient is inoperable; which in addition to the embolic effect (as seen with Transarterial- chemoembolisation-TACE) also gives the benefit of selectively irradiation to the target lesions with minimal toxicity to adjacent normal hepatocytes. However there is a risk of shunting of radioactive spheres to pulmonary circulation and subsequent pulmonary toxicity if the hepatopulmonary shunt fraction is high. The estimated lung dose becomes the limiting factor for the dose that can be delivered trans-arterially for radioembolisation of hepatic neoplasms.This is achieved by a pretreatment 99m Tc MAA study. Aim: The accuracy of 99m Tc-MAA Scintigraphy to predict the hepatopulmonary shunt fraction of 90 Y Theraspheres was evaluated by comparing it with that obtained by post therapeutic Bremsstrahlung imaging. Materials and Methods: Patients: 13 patients who underwent 90 Y Theraspheres radioembolisation of hepatic malignancies (both primary and secondary) underwent pre therapeutic 99m Tc- MAA Scintigraphy and post therapeutic 90 Y Bremsstrahlung Scintigraphy. 10-12 mCi of freshly prepared 99m Tc MAA was administered by selective hepatic artery cauterization. Planar and tomographic images were acquired within 1hr of radiopharmaceutical administration. IMAGE ACQUISITION 99m Tc MAA static images were acquired in 256 x 256 matrix (1000 KCnts) and SPECT were a 128 x 128 matrix with 64 frames (20 s/frame). The scan parameters for CT were 140 kV, 2.5 mAs, and 1-cm slices. SPECT images were corrected for attenuation and scatter. Post therapeutic 90 Y Bremsstrahlung imaging was done with HEGP collimator with photo peak centered at 140 KeV - 64.29% and +56% window width. SPECT/CT images were obtained using a dual-detector gamma-camera with a mounted 1-row CT scanner (Infinia Hawkeye; GE medical systems) to evaluate hepatic and extra hepatic tracer

  17. Albumin microspheres labeled with Ga-67 by chelation: concise communication

    International Nuclear Information System (INIS)

    Hnatowich, D.J.; Schlegel, P.

    1981-01-01

    Albumin microspheres have been synthesized with EDTA and DTPA chelating groups covalently bound to their surface. The microspheres may be labeled with Ga-67 at high yield (97 +- 2%) by transcomplexation from a 0.1 M Ga-67 acetate solution. With EDTA microspheres the resulting label dissociates only slightly after 24 hr in 50% plasma at 37 0 C, whereas with DTPA microspheres the label shows no detectable dissociation over this period. By contrast, microspheres without chelating groups lose their label virtually completely under these conditions. Following intravenous administration of sized Ga-67 DTPA microspheres in mice, about (84 +- 16)% of the activity localizes in the lungs at 5 min, with (60 +- 7)% remaining after 2 h. Since labeling is by chelation, the microspheres may also be tagged with other metallic radionuclides

  18. Dosimetry of a 90Y-hydroxide liquid brachytherapy treatment approach to canine osteosarcoma using PET/CT

    International Nuclear Information System (INIS)

    Zhou, Jien Jie; Gonzalez, Arnulfo; Lenox, Mark W.; Fossum, Theresa W.; Frank, R. Keith; Simon, Jaime; Stearns, Stan; Ruoff, Catherine M.; Wendt, Richard E.; Akabani, Gamal

    2015-01-01

    A new treatment strategy based on direct injections of 90 Y-hydroxide into the tumor bed in dogs with osteosarcoma was studied. Direct injections of the radiopharmaceutical into the tumor bed were made according to a pretreatment plan established using 18 F-FDG images. Using a special drill, cannulas were inserted going through tissue, tumor and bone. Using these cannulas, direct injections of the radiopharmaceutical were made. The in vivo biodistribution of 90 Y-hydroxide and the anatomical tumor bed were imaged using a time-of-flight (TOF) PET/CT scanner. The material properties of the tissues were estimated from corresponding CT numbers using an electron-density calibration. Radiation absorbed dose estimates were calculated using Monte Carlo methods where the biodistribution of the pharmaceutical from PET images was sampled using a collapsing 3-D rejection technique. Dose distributions in the tumor bed and surrounding tissues were calculated, showing significant heterogeneity with multiple hot spots at injection sites. Dose volume histograms showed that approximately 33.9% of bone and tumor and 70.2% of bone marrow and trabecular bone received an absorbed dose over 200 Gy; approximately 3.2% of bone and tumor and 31.0% of bone marrow and trabecular bone received a total dose of over 1000 Gy. - Graphical abstract: Treatment of canine osteosarcoma using 90 Y-hydroxide using localized liquid brachytherapy. A 3-D co-registered PET/CT image showing the distribution of 90 Y in the left tibia of a dog with osteosarcoma. Multiple high activity hotspots are shown within bone marrow and isolated hotspots within the tumor bed, corresponding to the sites of administration. Absorbed doses were estimated to be as high as 2000 Gy to tumor. - Highlights: • A liquid brachytherapy treatment of canine osteosarcoma using 90 Y hydroxyapatite is presented. • Dosimetry of 90 Y hydroxyapatite liquid brachytherapy was carried out using PET-CT. • Activity distribution correlated

  19. Inflammation-induced synergetic enhancement of nanoparticle treatments with DOXIL{sup ®} and {sup 90}Y-Lactosome for orthotopic mammary tumor

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, Kensuke; Ueda, Motoki [Graduate School of Medicine, Kyoto University, Department of Diagnostic Imaging and Nuclear Medicine (Japan); Hara, Isao [Shimadzu Corporation, Technology Research Laboratory (Japan); Hara, Eri [Kyoto University Hospital, Department of Experimental Therapeutics, Institute for Advancement of Clinical and Translational Science (Japan); Sano, Kohei [Graduate School of Medicine, Kyoto University, Department of Diagnostic Imaging and Nuclear Medicine (Japan); Makino, Akira [University of Fukui, Division of Molecular Imaging, Biomedical Imaging Research Center (Japan); Ozeki, Eiichi [Shimadzu Corporation, Technology Research Laboratory (Japan); Yamamoto, Fumihiko [Tohoku Pharmaceutical University, Department of Radiopharmacy (Japan); Saji, Hideo [Kyoto University, Department of Patho-Functional Bioanalysis, Graduate School of Pharmaceutical Sciences (Japan); Togashi, Kaori [Graduate School of Medicine, Kyoto University, Department of Diagnostic Imaging and Nuclear Medicine (Japan); Kimura, Shunsaku, E-mail: shun@scl.kyoto-u.ac.jp [Kyoto University, Department of Material Chemistry, Graduate School of Engineering (Japan)

    2016-05-15

    Polymeric micelles (Lactosome) in the size of 20–30 nm were labeled with radionuclides of {sup 111}In ({sup 111}In-DOTA-Lactosome) for SPECT imaging and {sup 90}Y ({sup 90}Y-DOTA-Lactosome) for β-ray irradiation for mammary tumor in mice. The tumor site at the femoral right leg grafted with 4T1 cells was clearly imaged at 24 h after the intravenous injection. Biodistribution revealed that the half-life time of {sup 111}In-DOTA-Lactosome was 11 h, which enabled the nanoparticle selectively accumulated in tumor site due to the enhanced permeability and retention (EPR) effect. The anti-tumor therapeutic effect of {sup 90}Y-DOTA-Lactosome was observed depending on the dose frequency and amount. Under the condition of the percutaneous ethanol injection treatment, the therapeutic effect of {sup 90}Y-DOTA-Lactosome was enhanced due to the super EPR effect. Owing to the super EPR effect, co-administration of {sup 90}Y-DOTA-Lactosome and DOXIL{sup ®} inhibited the tumor growth during 15 days with their administrations.

  20. Cellular and molecular properties of 90Y-labeled cetuximab in combination with radiotherapy on human tumor cells in vitro

    International Nuclear Information System (INIS)

    Saki, M.; Toulany, M.; Rodemann, H.P.; Sihver, W.; Zenker, M.; Heldt, J.M.; Mosch, B.; Pietzsch, H.J.; Steinbach, J.; Baumann, M.

    2012-01-01

    Purpose: Anti-EGFR antibody cetuximab (C225) is used in combination with radiotherapy of head and neck squamous cell carcinoma (HNSCC) patients. We investigated whether conjugation of cetuximab with trans-cyclohexyl-diethylene-triamine-pentaacetic acid (CHX-A''-DTPA) and radiolabeling with 90 Yttrium affect the molecular and cellular function of cetuximab and improve its combined effect with external-beam irradiation (EBI). Methods: The following cell lines were used: HNSCC UT5, SAS, FaDu, as well as A43, Chinese hamster ovary cells (CHO), and human skin fibroblast HSF7. Binding affinity and kinetics, specificity, retention, and the combination of 90 Y-cetuximab with EBI were evaluated. Results: Control cetuximab and CHX-A''-DTPA-cetuximab blocked the proliferation activity of UT5 cells. In combination with EBI, CHX-A''-DTPA-cetuximab increased the radiosensitivity of UT5 to a similar degree as control cetuximab did. In contrast, in SAS and HSF7 cells neither proliferation nor radiosensitivity was affected by either of the antibodies. Binding [ 90 Y]Y-CHX-A''-DTPA-cetuximab ( 90 Y-cetuximab) to EGFR in HNSCC cells occurred time dependently with a maximum binding at 24 h. Retention of 90 Y-cetuximab was similar in both HNSCC cell lines; 24 h after treatment, approximately 90% of bound activity remained in the cell layer. Competition assays, using cell membranes in the absence of an internalized fraction of cetuximab, showed that the cetuximab affinity is not lost as a result of conjugation with CHX-A''-DTPA. Cetuximab and CHX-A''-DTPA-cetuximab blocked EGF-induced Y1068 phosphorylation of EGFR. The lack of an effect of cetuximab on EGF-induced Akt and ERK1/2 phosphorylation and the inhibition of irradiation (IR)-induced Akt and ERK1/2 phosphorylation by cetuximab were not affected by DTPA conjugation. 90 Y-cetuximab in combination with EBI resulted in a pronounced inhibition of colony formation of HNSCC cells. Conclusions: Conjugation of CHX-A''-DTPA to cetuximab

  1. Optically Levitated Microspheres as a Probe for New Interactions

    Science.gov (United States)

    Rider, Alexander; Moore, David; Blakemore, Charles; Lu, Marie; Gratta, Giorgio

    2016-03-01

    We are developing novel techniques to probe new interactions at micron distances using optically levitated dielectric microspheres. Levitated microspheres are an ideal probe for short-range interactions because they are suspended using the radiation pressure at the focus of a laser beam, which means that the microspheres can be precisely manipulated and isolated from the surrounding environment at high vacuum. We have performed a search for unknown charged particles bound within the bulk of the microspheres. Currently, we are searching for the presence of a Chameleon field postulated to explain the presence of dark energy in the universe. In the future we plan to use optically levitated microspheres to search for micron length-scale gravity like interactions that could couple between a microsphere and another mass. We will present resent results from these experiments and plans for future searches for new interactions.

  2. Silicon Microspheres Photonics

    International Nuclear Information System (INIS)

    Serpenguzel, A.

    2008-01-01

    Electrophotonic integrated circuits (EPICs), or alternatively, optoelectronic integrated circuit (OEICs) are the natural evolution of the microelectronic integrated circuit (IC) with the addition of photonic capabilities. Traditionally, the IC industry has been based on group IV silicon, whereas the photonics industry on group III-V semiconductors. However, silicon based photonic microdevices have been making strands in siliconizing photonics. Silicon microspheres with their high quality factor whispering gallery modes (WGMs), are ideal candidates for wavelength division multiplexing (WDM) applications in the standard near-infrared communication bands. In this work, we will discuss the possibility of using silicon microspheres for photonics applications in the near-infrared

  3. Preparation of UN microspheres by internal gelation process

    Energy Technology Data Exchange (ETDEWEB)

    Shirasu, Yoshiro; Yamagishi, Shigeru [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-07-01

    UN microspheres were prepared from (UO{sub 3}+C) microspheres internally gelled in a hot silicone oil column. The gel microspheres were calcined at 480degC in nitrogen, after washing and drying. The calcined ones were carbothermically nitrided at 1400-1800degC in a nitrogen-based atmosphere in two ways: one in N{sub 2} followed by N{sub 2}-8%H{sub 2}, and the other in N{sub 2}-8%H{sub 2} only. In both cases, highly pure UN microspheres around 500 ppm of both oxygen and carbon impurities were obtained, although their densities were still low. (author)

  4. Country report: Germany. Preclinical evaluation of Y-90 labelled Rituximab and ERIC-1, two antibodies for tumor therapy

    Energy Technology Data Exchange (ETDEWEB)

    Schomäcker, Klaus; Fischer, Thomas [Department of Nuclear Medicine, University of Cologne, Cologne (Germany)

    2010-07-01

    This project focuses on harnessing the great potential of radionuclide therapy, using various different vehicles to transport radionuclides into tumor tissues. A central aim of the project will be to manufacture specific vehicle molecules whose tumor affinity and suitability for radioactive coupling have already been proven through laboratory trials on animals and cell cultures at the Department of Nuclear Medicine, University of Cologne and to label it with Y- 90. The vectors to be used to transport radionuclides into tumor tissue for treatment are antibodies against lymphomas and neuroblastomas. The technology applied for coupling Y-90 to various antibodies has been developed to a high level in Cologne and is now ready to be transferred and adapted to GMP (Good Manufacturing Practice) conditions. The antibody against NHL can be acquired commercially and must then be modified for binding to the therapeutically active nuclide Y-90. Similarly, the antibody against neuroblastoma must also be modified to bind to Y-90 but is produced in Cologne. To improve the therapeutic value of antibodies we tried to introduce the pretargeting method.

  5. Country report: Germany. Preclinical evaluation of Y-90 labelled Rituximab and ERIC-1, two antibodies for tumor therapy

    International Nuclear Information System (INIS)

    Schomäcker, Klaus; Fischer, Thomas

    2010-01-01

    This project focuses on harnessing the great potential of radionuclide therapy, using various different vehicles to transport radionuclides into tumor tissues. A central aim of the project will be to manufacture specific vehicle molecules whose tumor affinity and suitability for radioactive coupling have already been proven through laboratory trials on animals and cell cultures at the Department of Nuclear Medicine, University of Cologne and to label it with Y- 90. The vectors to be used to transport radionuclides into tumor tissue for treatment are antibodies against lymphomas and neuroblastomas. The technology applied for coupling Y-90 to various antibodies has been developed to a high level in Cologne and is now ready to be transferred and adapted to GMP (Good Manufacturing Practice) conditions. The antibody against NHL can be acquired commercially and must then be modified for binding to the therapeutically active nuclide Y-90. Similarly, the antibody against neuroblastoma must also be modified to bind to Y-90 but is produced in Cologne. To improve the therapeutic value of antibodies we tried to introduce the pretargeting method

  6. Preparation and biological evaluation of 111In-, 177Lu- and 90Y-labeled DOTA analogues conjugated to B72.3

    International Nuclear Information System (INIS)

    Mohsin, Huma; Fitzsimmons, Jonathan; Shelton, Tiffani; Hoffman, Timothy J.; Cutler, Cathy S.; Lewis, Michael R.; Athey, Phillip S.; Gulyas, Gyongyi; Kiefer, Garry E.; Frank, R. Keith; Simon, Jaime; Lever, Susan Z.; Jurisson, Silvia S.

    2007-01-01

    Three 1,4,7,10-tetraazacyclododecane-N,N',N '' ,N '' '-tetraacetic acid (DOTA) analogues were evaluated for relative in vivo stability when radiolabeled with 111 In, 90 Y and 177 Lu and conjugated to the monoclonal antibody B72.3. The DOTA analogues evaluated were 'NHS-DOTA' [N-hydroxysuccinimdyl (NHS) group activating one carboxylate], 'Arm-DOTA' (also known as MeO-DOTA; with a p-NCS, o-MeO-benzyl moiety on the methylene group of one acetic acid arm) and 'Back-DOTA' (with a p-NCS-benzyl moiety on a backbone methylene group of the macrocycle). The B72.3 was conjugated to the DOTA analogues to increase the retention time of the radioloabeled conjugates in vivo in mice. The serum stability of the various radiometalated DOTA conjugates showed them to have good stability out to 168 h (all >95% except 111 In-NHS-DOTA-B72.3, which was 91% stable). Hydroxyapatite stability for the 111 In and 177 Lu DOTA-conjugates was >95% at 168 h, while the 90 Y DOTA-conjugates were somewhat less stable (between 90% and 95% at 168 h). The biodistribution studies of the radiometalated DOTA-conjugates showed that no significant differences were observed for the 111 In and 177 Lu analogues; however, the 90 Y analogues showed lower stabilities, as evidenced by their increased bone uptake relative to the other two [2-20% injected dose per gram (% ID/g) for 90 Y and 2-8% ID/g for 111 In and 177 Lu]. The lower stability of the 90 Y analogues could be due to the higher beta energy of 90 Y and/or to the larger ionic radius of Y 3+ . Based on the bone uptake observed, the 177 Lu-NHS-DOTA-B72.3 had slightly lower stability than the 177 Lu-Arm-DOTA-B72.3 and 177 Lu-Back-DOTA-B72.3, but not significantly at all time points. For 90 Y, the analogue showing the lowest stability based on bone uptake was 90 Y-Arm-DOTA-B72.3, perhaps because of the metal's larger ionic radius and potential steric interactions minimizing effective complexation. The 111 In analogues all showed similar biological

  7. Activity measurements of {sup 18}F and {sup 90}Y with commercial radionuclide calibrators for nuclear medicine in Switzerland

    Energy Technology Data Exchange (ETDEWEB)

    Caffari, Yvan, E-mail: Yvan.Caffari@chuv.c [Institut de Radiophysique Appliquee, Grand-Pre 1, 1007 Lausanne (Switzerland); Spring, Philippe; Bailat, Claude; Nedjadi, Youcef; Bochud, Francois [Institut de Radiophysique Appliquee, Grand-Pre 1, 1007 Lausanne (Switzerland)

    2010-07-15

    The activity of radiopharmaceuticals in nuclear medicine is measured before patient injection with radionuclide calibrators. In Switzerland, the general requirements for quality controls are defined in a federal ordinance and a directive of the Federal Office of Metrology (METAS) which require each instrument to be verified. A set of three gamma sources (Co-57, Cs-137 and Co-60) is used to verify the response of radionuclide calibrators in the gamma energy range of their use. A beta source, a mixture of {sup 90}Sr and {sup 90}Y in secular equilibrium, is used as well. Manufacturers are responsible for the calibration factors. The main goal of the study was to monitor the validity of the calibration factors by using two sources: a {sup 90}Sr/{sup 90}Y source and a {sup 18}F source. The three types of commercial radionuclide calibrators tested do not have a calibration factor for the mixture but only for {sup 90}Y. Activity measurements of a {sup 90}Sr/{sup 90}Y source with the {sup 90}Y calibration factor are performed in order to correct for the extra-contribution of {sup 90}Sr. The value of the correction factor was found to be 1.113 whereas Monte Carlo simulations of the radionuclide calibrators estimate the correction factor to be 1.117. Measurements with {sup 18}F sources in a specific geometry are also performed. Since this radionuclide is widely used in Swiss hospitals equipped with PET and PET-CT, the metrology of the {sup 18}F is very important. The {sup 18}F response normalized to the {sup 137}Cs response shows that the difference with a reference value does not exceed 3% for the three types of radionuclide calibrators.

  8. 188Re-microspheres of albumin - the potential preparation for radiotherapy

    International Nuclear Information System (INIS)

    Dyomin, D.N.; Petriev, V.M.

    2000-01-01

    In this paper author describe preparation the albumin microspheres labelled with rhenium-188. We undertake an attempt to develop kits to the generator of rhenium-188 on the basis of albumin microspheres for radiotherapy of both oncological and non-oncological diseases. Microspheres, rhenium-188 with sizes 1 0-20 micron for treatment of rheumatoid arthritis (damage of large and intermediate joints), intraperitoneal administration and intrapleural administration at metastases covering a cavity. Microspheres, Re-188 with sizes 40-60 micron for treatment of disseminated kidney cancer (intraarterial, selectively), intratumoral administration to damaged nodules less than 2-3 cm. Microspheres, Re-188 with sizes 80-100 micron for large neoplasms and metastases of liver (intraarterial, selectively), intratumoral administration to damaged nodules with sizes over 3 cm. Preparation of albumin microspheres is carried out by thermal denaturation of protein in vegetable oil. Microspheres are obtained with the necessary range of sizes by ultrasonic fractionation. At our laboratory the method of preparation of albumin microspheres with any sizes of particles (from 5 -10 up to 800 -1000 microns) has been developed. (authors)

  9. Preoperative Surgical Discussion and Information Retention by Patients.

    Science.gov (United States)

    Feiner, David E; Rayan, Ghazi M

    2016-10-01

    To assess how much information communicated to patients is understood and retained after preoperative discussion of upper extremity procedures. A prospective study was designed by recruiting patients prior to undergoing upper extremity surgical procedures after a detailed discussion of their operative technique, postoperative care and treatment outcomes. Patients were given the same 20-item questionnaire to fill out twice, at two pre operative visits. An independent evaluator filled out a third questionnaire as a control. Various discussion points of the survey were compared among the 3 questionnaires and retained information and perceived comprehension were evaluated. The average patients' age was 50.3 (27-75) years The average time between the two surveys preoperative 1 and preoperative 2 was 40.7 (7-75) days,. The average patient had approximately 2 years of college or an associate's degree. Patients initially retained 73% (52-90%) of discussion points presented during preoperative 1 and 61% (36-85%) of the information at preoperative 2 p = .002. 50% of patients felt they understood 100% of the discussion, this dropped to only 10% at their preoperative 2 visit. 15% of our patients did not know what type of anesthesia they were having at preoperative 2. A communication barrier between patients and physicians exists when patients are informed about their preoperative surgical discussion. The retention of information presented is worsened with elapsing time from the initial preoperative discussion to the second preoperative visit immediately prior to surgery. Methods to enhance patients' retention of information prior to surgery must be sought and implemented which will improve patients' treatment outcome.

  10. Targeting of liver tumour in rats by selective delivery of holmium-166 loaded microspheres: a biodistribution study

    Energy Technology Data Exchange (ETDEWEB)

    Nijsen, F.; Rook, D.; Zonnenberg, B.; Klerk, J. de; Rijk, P. van; Schip, F. van het [Dept. of Nuclear Medicine, University Medical Center, Utrecht (Netherlands); Brandt, C. [Animal Inst., Utrecht Univ. (Netherlands); Meijer, R. [Dept. of Radiology, Univ. Medical Center, Utrecht (Netherlands); Dullens, H. [Dept. of Pathology, Univ. Medical Center, Utrecht (Netherlands); Hennink, W. [Dept. of Pharmaceutics, Utrecht Univ. (Netherlands)

    2001-06-01

    Intra-arterial administration of beta-emitting particles that become trapped in the vascular bed of a tumour and remain there while delivering high doses, represents a unique approach in the treatment of both primary and metastatic liver tumours. Studies on selective internal radiation therapy of colorectal liver metastases using yttrium-90 glass microspheres have shown encouraging results. This study describes the biodistribution of 40-{mu}m poly lactic acid microspheres loaded with radioactive holmium-166, after intra-arterial administration into the hepatic artery of rats with implanted liver tumours. Radioactivity measurements showed >95% retention of injected activity in the liver and its resident tumour. The average activity detected in other tissues was {<=}0.1%ID/g, with incidental exceptions in the lungs and stomach. Very little {sup 166}Ho activity was detected in kidneys (<0.1%ID/g), thereby indicating the stability of the microspheres in vivo. Tumour targeting was very effective, with a mean tumour to liver ratio of 6.1{+-}2.9 for rats with tumour (n=15) versus 0.7{+-}0.5 for control rats (n=6; P<0.001). These ratios were not significantly affected by the use of adrenaline. Histological analysis showed that five times as many large (>10) and medium-sized (4-9) clusters of microspheres were present within tumour and peritumoural tissue, compared with normal liver. Single microspheres were equally dispersed throughout the tumour, as well as normal liver parenchyma. (orig.)

  11. Microsphere-based super-resolution scanning optical microscope.

    Science.gov (United States)

    Huszka, Gergely; Yang, Hui; Gijs, Martin A M

    2017-06-26

    High-refractive index dielectric microspheres positioned within the field of view of a microscope objective in a dielectric medium can focus the light into a so-called photonic nanojet. A sample placed in such nanojet can be imaged by the objective with super-resolution, i.e. with a resolution beyond the classical diffraction limit. However, when imaging nanostructures on a substrate, the propagation distance of a light wave in the dielectric medium in between the substrate and the microsphere must be small enough to reveal the sample's nanometric features. Therefore, only the central part of an image obtained through a microsphere shows super-resolution details, which are typically ∼100 nm using white light (peak at λ = 600 nm). We have performed finite element simulations of the role of this critical distance in the super-resolution effect. Super-resolution imaging of a sample placed beneath the microsphere is only possible within a very restricted central area of ∼10 μm 2 , where the separation distance between the substrate and the microsphere surface is very small (∼1 μm). To generate super-resolution images over larger areas of the sample, we have fixed a microsphere on a frame attached to the microscope objective, which is automatically scanned over the sample in a step-by-step fashion. This generates a set of image tiles, which are subsequently stitched into a single super-resolution image (with resolution of λ/4-λ/5) of a sample area of up to ∼10 4 μm 2 . Scanning a standard optical microscope objective with microsphere therefore enables super-resolution microscopy over the complete field-of-view of the objective.

  12. Optimization of sustained release aceclofenac microspheres using response surface methodology

    Energy Technology Data Exchange (ETDEWEB)

    Deshmukh, Rameshwar K.; Naik, Jitendra B., E-mail: jitunaik@gmail.com

    2015-03-01

    Polymeric microspheres containing aceclofenac were prepared by single emulsion (oil-in-water) solvent evaporation method using response surface methodology (RSM). Microspheres were prepared by changing formulation variables such as the amount of Eudragit® RS100 and the amount of polyvinyl alcohol (PVA) by statistical experimental design in order to enhance the encapsulation efficiency (E.E.) of the microspheres. The resultant microspheres were evaluated for their size, morphology, E.E., and in vitro drug release. The amount of Eudragit® RS100 and the amount of PVA were found to be significant factors respectively for determining the E.E. of the microspheres. A linear mathematical model equation fitted to the data was used to predict the E.E. in the optimal region. Optimized formulation of microspheres was prepared using optimal process variables setting in order to evaluate the optimization capability of the models generated according to IV-optimal design. The microspheres showed high E.E. (74.14 ± 0.015% to 85.34 ± 0.011%) and suitably sustained drug release (minimum; 40% to 60%; maximum) over a period of 12 h. The optimized microspheres formulation showed E.E. of 84.87 ± 0.005 with small error value (1.39). The low magnitudes of error and the significant value of R{sup 2} in the present investigation prove the high prognostic ability of the design. The absence of interactions between drug and polymers was confirmed by Fourier transform infrared (FTIR) spectroscopy. Differential scanning calorimetry (DSC) and X-ray powder diffractometry (XRPD) revealed the dispersion of drug within microspheres formulation. The microspheres were found to be discrete, spherical with smooth surface. The results demonstrate that these microspheres could be promising delivery system to sustain the drug release and improve the E.E. thus prolong drug action and achieve the highest healing effect with minimal gastrointestinal side effects. - Highlights: • Aceclofenac microspheres

  13. Preparation of polymer microspheres by radiation-induced polymerization

    International Nuclear Information System (INIS)

    Naka, Y.; Yamamoto, Y.; Yoshida, Y.; Tagawa, S.

    1995-01-01

    Cross-liking monomer, diethylene glycol dimethacrylate gives microspheres from organic solution by radiation-induced polymerization. /One of the remarkable result is that the number of the microspheres is not changing during the polymerization. Ethyl methacrylate, maleic anhydride, styrene and acrylamide are used as comonomers. These comonomers give the microspheres in the range of 0 to 0.4 as mol fractions. (author)

  14. Development and biological evaluation of {sup 90}Y-BPAMD as a novel bone seeking therapeutic agent

    Energy Technology Data Exchange (ETDEWEB)

    Rabiei, Ali; Shamsaei, Mojtaba [Amir Kabir University of Technology, Tehran (Iran, Islamic Republic of). Energy Engineering and Physics Dept.; Yousefnia, Hassan; Zolghadri, Samaneh; Jalilian, Amir Reza [Nuclear Science and Technology Research Institute (NSTRI), Tehran (Iran, Islamic Republic of); Enayati, Razieh [Islamic Azad Univ. (IAU), Tehran (Iran, Islamic Republic of). Faculty of Engineering

    2016-07-01

    Nowadays, the bone-seeking radiopharmaceuticals play an important role in the treatment of the bone-related pathologies. Whereas various phosphonate ligands have already been identified, a DOTA-based bisphosphonate, 4-{[(bis(phosphonomethyl))carbamoyl]methyl}-7,10-bis(carboxymethyl) -1,4,7,10-tetraazacyclododec-1-yl (BPAMD) with better characteristics has recently been synthesized. In this study, {sup 90}Y-BPAMD was developed with radiochemical purity >98% and the specific activity of 3.52 TBq/mmol in the optimized conditions as a new bone-seeking therapeutic agent. The complex demonstrated significant stability at room temperature and in human serum even after 48 h. At even low amount of hydroxyapatite (5 mg), more than 90% binding to hydroxyapatite was observed. Biodistribution studies after injection of the complex into the Syrian rats showed major accumulation of the labelled compound in the bone tissue and an insignificant uptake in the other organs all the times after injection. Generally, {sup 90}Y-BPAMD demonstrated interesting characteristics compared to the other {sup 90}Y bone-seeking agents and even {sup 166}Ho-BPAMD, and can be considered as a new bone-seeking candidate for therapeutic applications.

  15. Antifouling peptide dendrimer surface of monodisperse magnetic poly(glycidyl methacrylate) microspheres

    Czech Academy of Sciences Publication Activity Database

    Hlídková, Helena; Kotelnikov, Ilya; Pop-Georgievski, Ognen; Proks, Vladimír; Horák, Daniel

    2017-01-01

    Roč. 50, č. 4 (2017), s. 1302-1311 ISSN 0024-9297 R&D Projects: GA ČR(CZ) GC16-01128J; GA ČR(CZ) GA16-02702S; GA ČR(CZ) GJ15-09368Y Grant - others:OPPK(XE) CZ.2.16/3.1.00/21545 Program:OPPK Institutional support: RVO:61389013 Keywords : poly(glycidyl methacrylate) * magnetic microspheres * peptides Subject RIV: CD - Macromolecular Chemistry OBOR OECD: Polymer science Impact factor: 5.835, year: 2016

  16. Preoperative β-cell function in patients with type 2 diabetes is important for the outcome of Roux-en-Y gastric bypass surgery

    DEFF Research Database (Denmark)

    Lund, Michael Taulo; Hansen, Merethe; Skaaby, Stinna

    2015-01-01

    INTRODUCTION: A major part of the patients with type 2 diabetes (T2DM) show remission after Roux-en-Y gastric bypass (RYGB). This is the result of increased postoperative insulin sensitivity and β-cell secretion. The aim of the present study was to elucidate the importance of the preoperative β-c...

  17. Beta radiation exposure of staff during and after therapies with 90Y-labelled substances

    International Nuclear Information System (INIS)

    Rimpler, A.; Barth, I.; Baum, R. B.; Senftleben, S.; Geworski, L.

    2008-01-01

    Radio-immuno-therapies (RITs) and peptide receptor radio-therapies (PRRTs) with 90 Y-labelled compounds offer promising prospects for tumor treatment in nuclear medicine. However, when preparing and performing these therapies, which require manipulations of high activities of 90 Y (>1 GBq), technicians and physicians may receive high exposures, mainly to the skin of the hands. Even non-occupationally exposed persons, such as caregivers and family members, receive external exposures in the initial period after therapy, arising from the 90 Y in the patient. The local skin doses of the individual staff members, measured during RITs and PRRTs with thermoluminescence detectors fixed with tapes to the fingers, vary considerably. The exposure of staff can exceed the annual permissible dose limit of 500 mSv if radiation protection standards are low. Thus, adequate safety measures are needed. Measurements of the dose rate around patients, made using survey meters with sufficient response to beta particles, indicate that the exposure of caregivers and family members is considerably higher than previously assumed, and was dominated by primary beta radiation instead of Bremsstrahlung. Nevertheless, under normal circumstances, the annual dose limits for the public (effective dose: 1 mSv, skin dose: 50 mSv) will be complied with. (authors)

  18. Spin-flip isovector giant resonances from the 90Zr (n,p) 90Y reaction at 200 MeV

    International Nuclear Information System (INIS)

    Raywood, K.J.; Spicer, B.M.

    1989-01-01

    Doubly differential cross sections of the reaction 90 Zr(n,p) 90 Y have been measured at 200 MeV for excitations up to 38 MeV in the residual nucleus. An overall resolution of 1.3 MeV was achieved. The spectra show qualitative agreement in shape and magnitude with recent RPA calculations; however all of the calculations underestimate the high excitation region of the spectra. A multipole decomposition of the data has been performed using differential cross sections calculated in the DWIA. An estimate of the Gamow-Teller strength in the reaction is given. The isovector spin-flip dipole giant resonance has been identified and there is also an indication of isovector monopole strength. 39 refs., 16 figs., 1 tab

  19. Thermal analysis of iron hydroxide microspheres

    International Nuclear Information System (INIS)

    Turcanu, C.N.; Cornescu, M.

    1979-03-01

    The thermal treatment is an important step in the preparative technology of the iron oxids microspheres with well established mechanical, physical and chemical characteristics. The first indications on the heating procedure have been obtained from the thermal analysis on iron hydroxide microspheres prepared by the support precipitation and internal gelification methods. (author)

  20. Nanomechanics of biocompatible hollow thin-shell polymer microspheres.

    Science.gov (United States)

    Glynos, Emmanouil; Koutsos, Vasileios; McDicken, W Norman; Moran, Carmel M; Pye, Stephen D; Ross, James A; Sboros, Vassilis

    2009-07-07

    The nanomechanical properties of biocompatible thin-shell hollow polymer microspheres with approximately constant ratio of shell thickness to microsphere diameter were measured by nanocompression tests in aqueous conditions. These microspheres encapsulate an inert gas and are used as ultrasound contrast agents by releasing free microbubbles in the presence of an ultrasound field as a result of free gas leakage from the shell. The tests were performed using an atomic force microscope (AFM) employing the force-distance curve technique. An optical microscope, on which the AFM was mounted, was used to guide the positioning of tipless cantilevers on top of individual microspheres. We performed a systematic study using several cantilevers with spring constants varying from 0.08 to 2.3 N/m on a population of microspheres with diameters from about 2 to 6 microm. The use of several cantilevers with various spring constants allowed a systematic study of the mechanical properties of the microsphere thin shell at different regimes of force and deformation. Using thin-shell mechanics theory for small deformations, the Young's modulus of the thin wall material was estimated and was shown to exhibit a strong size effect: it increased as the shell became thinner. The Young's modulus of thicker microsphere shells converged to the expected value for the macroscopic bulk material. For high applied forces, the force-deformation profiles showed a reversible and/or irreversible nonlinear behavior including "steps" and "jumps" which were attributed to mechanical instabilities such as buckling events.

  1. Somatostatin-based Radiopeptide Therapy with [177Lu-DOTA]-TOC versus [90Y-DOTA]-TOC in Neuroendocrine Tumors

    OpenAIRE

    Romer A Seiler D Marincek N Brunner P Koller MT Ng QK Maecke HR Muller-Brand J Rochlitz C B

    2014-01-01

    PURPOSE: Somatostatin based radiopeptide treatment is generally performed using the ß emitting radionuclides (90)Y or (177)Lu. The present study aimed at comparing benefits and harms of both therapeutic approaches. METHODS: In a comparative cohort study patients with advanced neuroendocrine tumours underwent repeated cycles of [(90)Y DOTA] TOC or [(177)Lu DOTA] TOC until progression of disease or permanent adverse events. Multivariable Cox regression and competing risks regression were emplo...

  2. [Preoperative fasting guidelines: an update].

    Science.gov (United States)

    López Muñoz, A C; Busto Aguirreurreta, N; Tomás Braulio, J

    2015-03-01

    Anesthesiology societies have issued various guidelines on preoperative fasting since 1990, not only to decrease the incidence of lung aspiration and anesthetic morbidity, but also to increase patient comfort prior to anesthesia. Some of these societies have been updating their guidelines, as such that, since 2010, we now have 2 evidence-based preoperative fasting guidelines available. In this article, an attempt is made to review these updated guidelines, as well as the current instructions for more controversial patients such as infants, the obese, and a particular type of ophthalmic surgery. Copyright © 2014 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Preparing microspheres of actinide nitrides from carbon containing oxide sols

    International Nuclear Information System (INIS)

    Triggiani, L.V.

    1975-01-01

    A process is given for preparing uranium nitride, uranium oxynitride, and uranium carboxynitride microspheres and the microspheres as compositions of matter. The microspheres are prepared from carbide sols by reduction and nitriding steps. (Official Gazette)

  4. Pyclen Tri-n-butylphosphonate Ester as Potential Chelator for Targeted Radiotherapy: From Yttrium(III) Complexation to (90)Y Radiolabeling.

    Science.gov (United States)

    Le Fur, Mariane; Beyler, Maryline; Lepareur, Nicolas; Fougère, Olivier; Platas-Iglesias, Carlos; Rousseaux, Olivier; Tripier, Raphaël

    2016-08-15

    The Y(3+) complex of PCTMB, the tri-n-butyl phosphonate ester of pyclen (3,6,9,15-tetraazabicyclo[9.3.1]pentadeca-1(15),11,13-triene), was synthesized as well as its Ho(3+) and Lu(3+) analogues. X-ray diffraction analyses revealed isomorphous dimeric M2(PCTMB)2·9H2O (M = Y, Ho, Lu) structures that crystallize in the centrosymmetric P1̅ triclinic space group. (1)H NMR and UV studies in aqueous solutions indicated that Y(3+) complexation is fast, being quantitative in 167 min at pH 3.8 and in 13 min at pH 5.5 (25 °C, acetate buffer, I = 0.150 M, [Y(3+)] = [PCTMB] = 0.2 mM). (1)H NMR DOSY and photon correlation spectroscopy experiments evidenced the formation of aggregates in chloroform with a bimodal distribution that changes slightly with concentration (11-24 and 240-258 nm). The behavior of the acid-assisted dissociation of the complex of Y(3+) with PCTMB was studied under pseudo-first-order conditions, and the half-life of the [Y(PCTMB)] complex in 0.5 M HCl at 25 °C was found to be 37 min, a value that decreases to 2.6 min in 5 M HCl. The Y(3+) complex of PCTMB is thermodynamically very stable, with a stability constant of log KY-PCTMB = 19.49 and pY = 16.7 measured by potentiometry. (90)Y complexation studies revealed fast radiolabeling kinetics; optimal radiolabeling conditions were obtained for (90)Y in acetate medium, PCTMB at 10(-4) to 10(-2) M in acetate buffer pH = 4.75, 15 min at 45-60 °C. In vitro stability studies in human serum showed that [(90)Y(PCTMB)] is quite stable, with about 90% of the activity still in the form of the radiotracer at 24 h and 80% from 48 h to 72 h. A comparison with other ligands such as PCTA, DOTA, and DTPA already used for in vivo application shows that [(90)Y(PCTMB)] is an interesting lipophilic and neutral analogue of these reference chelates for therapeutic applications in aqueous and nonaqueous media.

  5. Cellular and molecular properties of {sup 90}Y-labeled cetuximab in combination with radiotherapy on human tumor cells in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Saki, M.; Toulany, M.; Rodemann, H.P. [Tuebingen Univ. (Germany). Div. of Radiobiology and Molecular Environmental Research; Sihver, W.; Zenker, M.; Heldt, J.M.; Mosch, B.; Pietzsch, H.J.; Steinbach, J. [Helmholtz-Zentrum Dresden-Rossendorf (HZDR) e.V., Dresden (Germany). Inst. of Radiopharmacy; Baumann, M. [Technische Univ. Dresden (Germany). Dept. of Radiation Oncology

    2012-09-15

    Purpose: Anti-EGFR antibody cetuximab (C225) is used in combination with radiotherapy of head and neck squamous cell carcinoma (HNSCC) patients. We investigated whether conjugation of cetuximab with trans-cyclohexyl-diethylene-triamine-pentaacetic acid (CHX-A''-DTPA) and radiolabeling with {sup 90}Yttrium affect the molecular and cellular function of cetuximab and improve its combined effect with external-beam irradiation (EBI). Methods: The following cell lines were used: HNSCC UT5, SAS, FaDu, as well as A43, Chinese hamster ovary cells (CHO), and human skin fibroblast HSF7. Binding affinity and kinetics, specificity, retention, and the combination of {sup 90}Y-cetuximab with EBI were evaluated. Results: Control cetuximab and CHX-A''-DTPA-cetuximab blocked the proliferation activity of UT5 cells. In combination with EBI, CHX-A''-DTPA-cetuximab increased the radiosensitivity of UT5 to a similar degree as control cetuximab did. In contrast, in SAS and HSF7 cells neither proliferation nor radiosensitivity was affected by either of the antibodies. Binding [{sup 90}Y]Y-CHX-A''-DTPA-cetuximab ({sup 90}Y-cetuximab) to EGFR in HNSCC cells occurred time dependently with a maximum binding at 24 h. Retention of {sup 90}Y-cetuximab was similar in both HNSCC cell lines; 24 h after treatment, approximately 90% of bound activity remained in the cell layer. Competition assays, using cell membranes in the absence of an internalized fraction of cetuximab, showed that the cetuximab affinity is not lost as a result of conjugation with CHX-A''-DTPA. Cetuximab and CHX-A''-DTPA-cetuximab blocked EGF-induced Y1068 phosphorylation of EGFR. The lack of an effect of cetuximab on EGF-induced Akt and ERK1/2 phosphorylation and the inhibition of irradiation (IR)-induced Akt and ERK1/2 phosphorylation by cetuximab were not affected by DTPA conjugation. {sup 90}Y-cetuximab in combination with EBI resulted in a pronounced inhibition of

  6. Development of radioinmunoconjugate 90Y-DOTA-nimotuzumab-Fab for therapy of EGFR over expressing tumors

    International Nuclear Information System (INIS)

    Rodriguez, A. M.; Alonso, L. M.; Gongora, M.; Leyva, R.; Solana, A.

    2015-01-01

    Many monoclonal antibodies conjugated with 1,4,7,10-tetraaza cyclododecane-N, N', N'', N'''-tetraacetic acid (DOTA) and radiolabeled with 90 Y, have been used for radioimmunotherapy. As know IgG molecules are heavy proteins with a molecular weight of approximately 150 kDa. Accordingly, intact IgG antibodies may have significant slow kinetics biodistribution and severely limited properties of tissue penetration. Antibody fragments labeled with radio metals could be promising radiopharmaceuticals for imaging and non-invasive therapy due to its high affinity to the tumor, the lack of effector function and rapid pharmacokinetic. In this work, the nimotuzumab Fab fragment was obtained by cleavage with papain in molar excess. After separating the reaction mixture in three steps using affinity, size exclusion and ion exchange chromatography; the Fab fragment showed high values of purity, integrity and identity. The Fab fragment was derivatized with DOTA and labeled with 90 Y. The radioimmunoconjugate with high radiochemical yield was assessed by in vitro stability with an excess of 50mM DTPA. The development of 90 Y-DOTA-Nimotuzumab-Fab radioimmunoconjugate allows to count on as a potential agent for radioimmunotherapy. (Author)

  7. Mesoporous metal oxide microsphere electrode compositions and their methods of making

    Science.gov (United States)

    Parans Paranthaman, Mariappan; Bi, Zhonghe; Bridges, Craig A.; Brown, Gilbert M.

    2017-04-11

    Compositions and methods of making are provided for treated mesoporous metal oxide microspheres electrodes. The compositions include microspheres with an average diameter between about 200 nanometers and about 10 micrometers and mesopores on the surface and interior of the microspheres. The methods of making include forming a mesoporous metal oxide microsphere composition and treating the mesoporous metal oxide microspheres by at least annealing in a reducing atmosphere, doping with an aliovalent element, and coating with a coating composition.

  8. Tumor-targeting properties of 90Y- and 177Lu-labeled α-melanocyte stimulating hormone peptide analogues in a murine melanoma model

    International Nuclear Information System (INIS)

    Miao Yubin; Hoffman, Timothy J.; Quinn, Thomas P.

    2005-01-01

    The purpose of this study was to compare the tumor-targeting properties of 90 Y-DOTA-Re(Arg 11 )CCMSH and 177 Lu-DOTA-Re(Arg 11 )CCMSH in a murine melanoma mouse model. Methods: The in vitro properties of cellular internalization and retention of 90 Y-DOTA-Re(Arg 11 )CCMSH and 177 Lu-DOTA-Re(Arg 11 )CCMSH were studied in B16/F1 murine melanoma cells. The pharmacokinetics of 90 Y-DOTA-Re(Arg 11 )CCMSH and 177 Lu-DOTA-Re(Arg 11 )CCMSH were determined in B16/F1 melanoma-bearing C57 mice. Results: 90 Y-DOTA-Re(Arg 11 )CCMSH and 177 Lu-DOTA-Re(Arg 11 )CCMSH exhibited fast cellular internalization and extended cellular retention in B16/F1 cells. High receptor-mediated tumor uptake and retention coupled with fast whole-body clearance of 90 Y-DOTA-Re(Arg 11 )CCMSH and 177 Lu-DOTA-Re(Arg 11 )CCMSH were demonstrated in B16/F1 tumor-bearing C57 mice. The tumor uptakes of 90 Y-DOTA-Re(Arg 11 )CCMSH and 177 Lu-DOTA-Re(Arg 11 )CCMSH were 25.70±4.64 and 14.48±0.85 %ID/g at 2 h, and 14.09±2.73 and 17.68±3.32 %ID/g at 4 h postinjection. There was little activity accumulated in normal organs except for kidney. Conclusions: High tumor-targeting properties of 90 Y-DOTA-Re(Arg 11 )CCMSH and 177 Lu-DOTA-Re(Arg 11 )CCMSH highlighted their potential as radiopharmaceuticals for targeted radionuclide therapy of melanoma in further investigations

  9. In vitro Evaluation of Nateglinide-Loaded Microspheres Formulated ...

    African Journals Online (AJOL)

    Keywords: Nateglinide, Microspheres, Micromeritics, Drug release, Ionic ... Oral drug delivery systems (DDS) are commonly divided into immediate release and modified release systems. ..... Albumin Microspheres for Potential Intramuscular.

  10. Study on the Degradation of Polylactide Microsphere In Vitro

    Institute of Scientific and Technical Information of China (English)

    HeYing; WeiShuli

    2001-01-01

    This report concentrated on the rules and mechanism of the degradation of polylactide and the microspheres. The rate of degradation was assessed with five methods: observation of microsphere surface morphology by SEM, determination of the weight loss of the microspheres, determination of the molecular mass of the polymers by GPC, determination of pH and determination of the contents of lactic acid by UV spectrophotometry. The degradation of polylactide microspheres showed two-phase characteristics. At the early stage of the degradation, the high molecular mass polymers were cleaved into lower molecular mass fractions and at the late stage, there was a period of erosion and weight loss of the microspheres. The degradation was much slower for polymers with a higher molecular mass. The polylactide degradation showed good regularity.

  11. Preparation and Characterization of Fluorescent SiO2 Microspheres

    Science.gov (United States)

    Xu, Cui; Zhang, Hao; Guan, Ruifang

    2018-01-01

    Fluorescent compound without typical fluorophores was synthesized with citric acid (CA) and aminopropyltriethoxysilane (APTS) firstly, and then it was grafted to the surface of the prepared SiO2 microspheres by chemical reaction. The fluorescent SiO2 microspheres with good fluorescent properties were obtained by optimizing the reaction conditions. And the morphology and structure of the fluorescent SiO2 microspheres have been characterized by scanning electron microscopy (SEM) and fourier transform infrared (FTIR) spectroscopy. The results showed that the preparation of fluorescent SiO2 microspheres have good monodispersity and narrow particle size distribution. Moreover, the fluorescent SiO2 microspheres can be applied to detect Fe3+ in aqueous solution, prepare fluorescent SiO2 rubber, and have potential to be applied in the fluorescent labeling and fingerprint appearing technique fields.

  12. Country report: Pakistan. Second Research Co-ordination Meeting on Development of Radiopharmaceuticals Based on {sup 188}Re and {sup 90}Y for Radionuclide Therapy, 22-26 March 2010, Vienna

    Energy Technology Data Exchange (ETDEWEB)

    Mansur, M. S.; Mushtaq, A. [Isotope Production Division, Pakistan Institute of Nuclear Science and Technology, P.O. Nilore, Islamabad (Pakistan)

    2010-07-01

    Various experiments were carried out for the separation of {sup 90}Y from {sup 90}Sr using colloid formation behavior of {sup 90}Y in basic pH range. When the acidic solution of {sup 90}Sr/{sup 90}Y was treated with NaOH and passed through a small glass wool column, more than 95% {sup 90}Y was retained on glass wool, which was further washed with 0.1 M NaOH. The {sup 90}Y was extracted in 1 M HCl. Radionuclidic purity was determined by half life measurement. The contamination of parent was less than 0.0001%. Similarly when the colloid was passed through membrane filter more than 95% {sup 90}Y was retained which was recovered by 1 M HCl. The contamination of {sup 90}Sr was less than 0.0001%. The stock solution of {sup 90}Sr/{sup 90}Y in NH{sub 4}OH/NaOH was again passed through Millipore filter paper or glass wool after one week. The retention of 90Y was insignificant. The equilibrium mixture of {sup 90}Sr/{sup 90}Y was acidified with HCl and again precipitated with addition of NH{sub 4}OH or NaOH. The basic solution was passed through the Millipore filter or glass wool. More than 90% activity of {sup 90}Y was retained, which was finally extracted in 1 M HCl It was concluded that for recovery of {sup 90}Y from {sup 90}Sr by colloid formation, the acidic solution of {sup 90}Sr/{sup 90}Y shall be freshly precipitated by NH{sub 4}OH or NaOH. It was also observed that the adsorption of {sup 90}Y was quite high when the {sup 90}Sr solution was left in a glass vial for the growth of {sup 90}Y. However it can be easily extracted after keeping it in boiling water bath for few minutes. The separated {sup 90}Y via colloid formation was used for the labeling of EDTMP. Labeling efficiency of {sup 90}Y-EDTMP was more than 98%.

  13. Calibration and validation of a quality assurance system for {sup 90}Sr/{sup 90}Y radiation source trains

    Energy Technology Data Exchange (ETDEWEB)

    Rosenthal, P [Department of Radiation Therapy and Oncology, Freie Universitaet Berlin, Benjamin Franklin University Medical Centre, Hindenburgdamm 30, D-12200 Berlin (Germany); Weber, W [Novoste GmbH, Huettenallee 237 c, D-47800 Krefeld (Germany); Foerster, A [Department of Radiation Therapy and Oncology, Freie Universitaet Berlin, Benjamin Franklin University Medical Centre, Hindenburgdamm 30, D-12200 Berlin (Germany); Orth, O [Department of Radiation Therapy and Oncology, Freie Universitaet Berlin, Benjamin Franklin University Medical Centre, Hindenburgdamm 30, D-12200 Berlin (Germany); Koehler, B [Department of Radiation Therapy and Oncology, Freie Universitaet Berlin, Benjamin Franklin University Medical Centre, Hindenburgdamm 30, D-12200 Berlin (Germany); Seiler, F [Department of Radiation Therapy and Oncology, Freie Universitaet Berlin, Benjamin Franklin University Medical Centre, Hindenburgdamm 30, D-12200 Berlin (Germany)

    2003-03-07

    A quality assurance system (OPTIDOS, PTW-Freiburg) developed for dose rate verification of {sup 90}Sr/{sup 90}Y radiation source trains (RSTs) was calibrated and validated. These source trains are used in the 5-F-BetaCath{sup TM} system (Novoste Corp.) for the treatment of endovascular diseases. The calibration factor of the OPTIDOS system was obtained empirically and is valid for {sup 90}Sr/{sup 90}Y dose rate measurements at the specification point which is located at 2 mm distance from the source axis. A total of 187 OPTIDOS dose rate verifications of the 5-F-BetaCath{sup TM} system were performed in different hospitals. The histogram of the deviation between the manufacturer's dose rate specification and the dose rate measured using the OPTIDOS dosimetry system is Gaussian shaped with {+-}3% relative width and a mean shift of about +2% with respect to the corresponding dose rate specification. Additionally, 128 OPTIDOS dose rate verifications of the new jacketed RST (3.5-F-BetaCath{sup TM}, Novoste Corp.) were performed using the same calibration factor as derived for the 5-F-BetaCath{sup TM} system. Distribution of the deviation between the certified and the measured dose rate is nearly identical in comparison to the histogram of the 5-F-BetaCath{sup TM} system. The mean value of the deviations is shifted by -1.5% with respect to the certified dose rate. In order to compare the results of the calibrated OPTIDOS dosimetry system with a standard measuring method, separate dose rate measurements were performed using electron accelerator calibrated radiochromic films in which calibration is traceable to PTB (Physikalisch Technische Bundesanstalt, Germany). Deviation between both the methods is less than 3.1%. These results confirm that the calibrated OPTIDOS dosimetry system can be considered suitable for quality assurance of both types of RST used in the BetaCath{sup TM} systems.

  14. Robust platforms for creating organic-inorganic nanocomposite microspheres: decorating polymer microspheres containing mussel-inspired adhesion layers with inorganic nanoparticles.

    Science.gov (United States)

    Satoh, H; Saito, Y; Yabu, H

    2014-12-07

    We describe a method for creating robust and stable core-shell polymer microspheres decorated with inorganic (IO) nanoparticles (NPs) by a self-organization process and heterocoagulation using a mussel-inspired polymer adhesive layer between the IO NPs and the microspheres.

  15. ANÁLISIS COMPARATIVO DE LOS EFECTOS AGUDOS DE SESIONES DE ENTRENAMIENTO DE FUERZA CON CARGAS DEL 90 Y 30% 1 RM.

    Directory of Open Access Journals (Sweden)

    Jorge Dopico Calvo

    2010-10-01

    Full Text Available En una medición inicial (Pretest se obtuvo la 1RM de 23 sujetos masculinos en el ejercicio press banca, así como la potencia y fuerza media aplicada al 90 y 30% de 1RM (PMED90, FMED90, PMED30, FMED 30. Posteriormente 11 sujetos (Gr90 llevaron a cabo 2 sesiones de entrenamiento con cargas del 90%, mientras los 12 sujetos restantes (Gr30 lo hacían con cargas del 30%. Inmediatamente finalizada cada una de las sesiones se valoraba nuevamente PMED90, FMED90, PMED30, FMED30. Una semana después de la finalización de los entrenamientos se efectuó un Postest. Los resultados mostraron una mejora estadísticamente significativa del rendimiento de Gr30 al final de cada una de las sesiones de entrenamiento, respecto a Pretest y Postest, con el 90% de 1RM, mientras que Gr90 obtuvo mejoras significativas con el 30% respecto a Pretest, pero no respecto a Postest.
    PALABRAS CLAVE: fuerza, potencia, medición, efecto agudo.

  16. Polyvinylpyrrolidone (PVP)-assisted hydrothermal synthesis of luminescent YVO4:Eu3+ microspheres

    International Nuclear Information System (INIS)

    Wang Juan; Xu Yunhua; Hojamberdiev, Mirabbos; Wang Mingqiong; Zhu Gangqiang

    2010-01-01

    Spherical YVO 4 :Eu 3+ microstructures were hydrothermally synthesized by the reaction of NH 4 VO 3 , Y 2 O 3 , and Eu 2 O 3 at 180 deg. C for 24 h with the assistance of polyvinylpyrrolidone (PVP) as a surfactant. The resulting products were characterized by X-ray powder diffraction (XRD), scanning electron microscopy (SEM), and photoluminescence (PL) spectroscopy. The experimental results showed that ball-like YVO 4 :Eu 3+ microspheres with a diameter of about 4-5 μm, corresponding to the SEM observations, formed at 180 deg. C for 24 h using 0.2 g PVP with the molecular weight of 20,000 g mol -1 . The amount of PVP and the reaction time of hydrothermal processing were found to play a key role in the formation of YVO 4 :Eu 3+ microspheres. It has been observed that the relative luminescence intensities of the as-synthesized samples increased with increasing hydrothermal reaction times due mainly to the increase of crystallinity.

  17. 5-Fluorouracil:carnauba wax microspheres for chemoembolization: an in vitro evaluation.

    Science.gov (United States)

    Benita, S; Zouai, O; Benoit, J P

    1986-09-01

    5-Fluorouracil:carnauba wax microspheres were prepared using a meltable dispersion process with the aid of a surfactant as a wetting agent. It was noted that only hydrophilic surfactants were able to wet the 5-fluorouracil and substantially increased its content in the microspheres. No marked effect was observed in the particle size distribution of the solid microspheres as a function of the nature of the surfactant. Increasing the stirring rate in the preparation process decreased, first, the mean droplet size of the emulsified melted dispersion in the vehicle during the heating process, and, consequently, the mean particle size of the solidified microspheres during the cooling process. 5-Fluorouracil cumulative release from the microspheres followed first-order kinetics, as shown by nonlinear regression analysis. Although the kinetic results were not indicative of the true release mechanism from a single microsphere, it was believed that 5-fluorouracil release from the microspheres was probably governed by a dissolution process, rather than by a leaching process through the carnauba wax microspheres.

  18. Study On The Preparation Of 90Y-DTPA-Rituximab For Non-Hodgkin Lymphoma Treatment

    International Nuclear Information System (INIS)

    Nguyen Thi Thu; Duong Van Dong; Bui Van Cuong; Vo Thi Cam Hoa; Chu Van Khoa; Phan Quoc Thong

    2011-01-01

    Yttrium is one of the most useful radionuclides for radioimmunotherapeutic applications, especially labelling with monoclonal antibodies. Rituximab was bound to the DTPA chelating agent using Hnatowich methods. Cyclic anhydride DTPA (cDTPAa, 0.1 mg/ml) was dissolved in chloroform and was degassed under a stream of nitrogen for 30 minutes. Rituximab solution in 0.05 M bicarbonate buffer was immediately added and mixed for one minute at room temperature. The antibody Rituximab at different concentration (5 mg/ml and 10 mg/ml) was coupled with the cDTPAa, at molar ratios (cDTPAa : Rituximab) of 1:1, 3:1, 5:1, 10:1 and 20:1. The conjugation of DTPA-Rituximab mixture was labelled with Y-90, then using Sephadex G25 in order to determine coupling efficiency. Coupling efficiency at a 3:1 mole ratio was 70%. After purification, the conjugation DTPA-Rituximab was labeled with Y-90 in 0.5 M acetate buffer, pH 5, at room temperature. The labeling yield was about 99%. The radiochemical purity of 90 Y-DTPA-Rituximab was more than 98 % which determined by ITLC in 0.1 M acetate at pH 6 as mobile phase. The radiopharmaceuticals have been test for sterility, apyrogenicity and biodistribution. This is a potential radiopharmaceutical for clinical application in therapeutic Non Hodgkin Lymphoma treatments. (author)

  19. Preparation of porous zirconia microspheres by internal gelation method

    International Nuclear Information System (INIS)

    Pathak, Sachin S.; Pius, I.C.; Bhanushali, R.D.; Rao, T.V. Vittal; Mukerjee, S.K.

    2008-01-01

    A modified internal gelation process for the preparation of porous zirconia microspheres has been developed. The conventional method has been modified by adding a surfactant in the feed broth. The effects of variation of surfactant concentration, washing techniques and temperature of calcination on the pore volume and the surface area of the microspheres have been studied. The conditions were optimized to obtain porous stable microspheres suitable for various applications. The microspheres were characterized by surface area analysis, pore volume analysis, thermogravimetric analysis and X-ray diffraction. The ion exchange behavior was studied using pH titration

  20. Effect of various polymers concentrations on physicochemical properties of floating microspheres.

    Science.gov (United States)

    Jagtap, Y M; Bhujbal, R K; Ranade, A N; Ranpise, N S

    2012-11-01

    Floating microspheres have emerged as a potential candidate for gastroretentive drug delivery system. For developing a desired intragastric floatation system employing these microspheres, it is necessary to select an appropriate balance between buoyancy and drug releasing rate. These properties mainly depend on the polymers used in the formulation of the microspheres. Hence it is necessory to study the effect of these polymer concentrations on the various physicochemical properties of the microspheres. Floating microspheres were prepared by emulsion solvent evaporation technique utilising different polymers such as ethyl cellulose, Eudragit(®) RS and Eudragit(®) RL by dissolving them in a mixture of dichloromethane and methanol. Release modifiers studied were hydroxypropyl methylcellulose K4M, hydroxypropyl methylcellulose E50 LV and Eudragit(®) EPO. Prepared microspheres were analysed for particle size, surface morphology, entrapment efficiency, buoyancy, differential scanning calorimetry and in-vitro drug release. Ethyl cellulose and Eudragit(®) EPO resulted microspheres with high percentage yield, excellent spherical shape but had very less buoyancies with a high cumulative drug release. Ethyl cellulose microspheres prepared using hydroxypropyl methylcellulose K4M showed more sustained drug release and high buoyancies than that of the microspheres formulated with the hydroxypropyl methylcellulose E50 LV. Amongst these hydroxypropyl methylcellulose E50 LV showed good balance between buoyancy and the drug release.

  1. New modalities (setting, fractionation) of radioimmunotherapy by 90Y-ibritumomab tiuxetan (90Y zevalin) in first line treatment of follicular type non Hodgkin malignant lymphomas: efficiency, toxicity and personalized dosimetry approach

    International Nuclear Information System (INIS)

    Morschhauser, F.

    2008-12-01

    Rationale: radioimmunotherapy (R.I.T.) with 90 Y-ibritumomab tiuxetan ([ 90 Y] Zevalin ) is a new treatment option for patients with relapsed/refractory non Hodgkin follicular lymphoma (F.L.). Efficacy increases when Zevalin is used earlier in the disease course. Currently, Zevalin dosage is based on weight and not dosimetry. This most likely results in a wide range of absorbed dose to critical organs and tumor, which in turn translates in unpredictable efficacy and toxicity. Optimizing R.I.T. with [ 90 Y] Zevalin will require its use as part of first-line therapy and implementation of patient-specific dosimetry methods in clinical trials. Objectives and methods: we have consecutively studied 2 new modalities of using Zevalin in first line therapy of F.L.. First, we conducted an international, randomized, phase 3 trial to evaluate the efficacy and safety of consolidation with Zevalin(15 MBq/Kg) in patients with advanced-stage F.L. achieving at least a partial response after induction immuno chemotherapy. A second approach consisted of evaluating a fractionated schedule with 2 doses of Zevalin (11.1 MBq/kg each), 9 to 13 weeks apart, as front line therapy in F.L. patients with high tumor burden. As part of this second approach, we designed a refined imaging-based (planar and 3-dimensional) dosimetry protocol to improve prediction of dose efficacy and toxicity after each dose of zevalin. Data acquisition was performed in 3 centers (Lille, Nantes and Manchester) while data treatment and specific dose calculations for major organ, tumor masses and bone marrow were centralized. Conclusion: Consolidation of first remission with 90 Y-ibritumomab tiuxetan in advanced-stage follicular lymphoma is highly effective with no unexpected toxicities, prolonging P.F.S. by 2 years and resulting in high P.R.-to-C.R. conversion rates regardless of type of first-line induction treatment. Preliminary data show the feasibility of front line fractionated R.I.T. with Zevalin in patient

  2. Peptide Receptor Radionuclide Therapy with ''9''0Y DOTA TATE - First Results

    International Nuclear Information System (INIS)

    Artiko, V.; Sobic-Saranovic, D.; Petrovic, N.; Damjanovic, S.; Obradovic, V.

    2009-01-01

    Aim: The aim of this work is presentation of the preliminary results of the therapy of NETs with 90 Y DOTA TATE. Patients and methods: We investigated 15 patients with various neuroendocrine tumors. In all of them, together with other laboratory analyses and imaging methods, scintigraphy with somatostatin analogues was performed (in 3 with 111 In Octreoscan and in the other 4 with 99m Tc Tektrotyd) and high tumor uptake observed. The therapy was performed with 2-4,5 GBq 90 Y DOTA TATE per patient per one cycle, in the slow infusion in the physiological liquid (150 ml/15 min).Between the cycles, there was a time delay of 6-8 weeks. 30 minutes before the therapy, patients began receiving the infusion of amino acids (arginine and lysine) which lasted 4h. Before that, all therapies with somatostatin analogues were withdrawn. 24h-96h after the therapy, ''bremsstrahlung'' whole body imaging, SPECT and particular planar images were performed with gamma camera. Results: Analysis of the ''bremsstrahlung'' images showed uptake of the radiopharmaceutical in the liver, but the most of the activity was observed in the regions of the ''hot spots'' registered with previous 99m Tc Tektrotyd and 111 In Octreoscan images. According to our results, after the therapy, in two patients occurred progressive disease (PD), in seven stable disease (SD), and in six partial remission (PR). Up to now, there were no major clinical side effects hepatic function. Transient pancytopenia occurred in two patients, and impairment of kidney function in one. Conclusion: In spite of insufficient data, beneficial effects on clinical symptoms, hormone production and tumor proliferation were found, without major clinical side effects. Thus, according to preliminary results, treatment with 90 Y DOTA TATE is feasible method and might be useful for the management of patients with inoperable or disseminated neuroendocrine tumors. (author)

  3. Biocompatibility of Polyhydroxybutyrate Microspheres: in vitro and in vivo Evaluation

    OpenAIRE

    Shishatskaya, Ekaterina I.; Voinova, Olga N.; Goreva, Anastasya V.; Mogilnaya, Olga A.; Volova, Tatiana G.

    2008-01-01

    Microspheres have been prepared from the resorbable linear polyester of β-hydroxybutyric acid (polyhydroxybutyrate, PHB) by the solvent evaporation technique and investigated in vitro and in vivo. Biocompatibility of the microspheres has been proved in tests in the culture of mouse fibroblast cell line NIH 3Т3 and in experiments on intramuscular implantation of the microspheres to Wistar rats for 3 months. Tissue response to the implantation of polymeric microspheres has been found to consist...

  4. Development of Risperidone PLGA Microspheres

    Directory of Open Access Journals (Sweden)

    Susan D’Souza

    2014-01-01

    Full Text Available The aim of this study was to design and evaluate biodegradable PLGA microspheres for sustained delivery of Risperidone, with an eventual goal of avoiding combination therapy for the treatment of schizophrenia. Two PLGA copolymers (50 : 50 and 75 : 25 were used to prepare four microsphere formulations of Risperidone. The microspheres were characterized by several in vitro techniques. In vivo studies in male Sprague-Dawley rats at 20 and 40 mg/kg doses revealed that all formulations exhibited an initial burst followed by sustained release of the active moiety. Additionally, formulations prepared with 50 : 50 PLGA had a shorter duration of action and lower cumulative AUC levels than the 75 : 25 PLGA microspheres. A simulation of multiple dosing at weekly or 15-day regimen revealed pulsatile behavior for all formulations with steady state being achieved by the second dose. Overall, the clinical use of Formulations A, B, C, or D will eliminate the need for combination oral therapy and reduce time to achieve steady state, with a smaller washout period upon cessation of therapy. Results of this study prove the suitability of using PLGA copolymers of varying composition and molecular weight to develop sustained release formulations that can tailor in vivo behavior and enhance pharmacological effectiveness of the drug.

  5. Somatostatin-based radiotherapy with [90Y-DOTA]-TOC in neuroendocrine tumors: long-term outcome of a phase I dose escalation study.

    Science.gov (United States)

    Marincek, Nicolas; Jörg, Ann-Catherine; Brunner, Philippe; Schindler, Christian; Koller, Michael T; Rochlitz, Christoph; Müller-Brand, Jan; Maecke, Helmut R; Briel, Matthias; Walter, Martin A

    2013-01-15

    We describe the long-term outcome after clinical introduction and dose escalation of somatostatin receptor targeted therapy with [90Y-DOTA]-TOC in patients with metastasized neuroendocrine tumors. In a clinical phase I dose escalation study we treated patients with increasing [90Y-DOTA]-TOC activities. Multivariable Cox regression and competing risk regression were used to compare efficacy and toxicities of the different dosage protocols. Overall, 359 patients were recruited; 60 patients were enrolled for low dose (median: 2.4 GBq/cycle, range 0.9-7.8 GBq/cycle), 77 patients were enrolled for intermediate dose (median: 3.3 GBq/cycle, range: 2.0-7.4 GBq/cycle) and 222 patients were enrolled for high dose (median: 6.7 GBq/cycle, range: 3.7-8.1 GBq/cycle) [90Y-DOTA]-TOC treatment. The incidences of hematotoxicities grade 1-4 were 65.0%, 64.9% and 74.8%; the incidences of grade 4/5 kidney toxicities were 8.4%, 6.5% and 14.0%, and the median survival was 39 (range: 1-158) months, 34 (range: 1-118) months and 29 (range: 1-113) months. The high dose protocol was associated with an increased risk of kidney toxicity (Hazard Ratio: 3.12 (1.13-8.59) vs. intermediate dose, p = 0.03) and a shorter overall survival (Hazard Ratio: 2.50 (1.08-5.79) vs. low dose, p = 0.03). Increasing [90Y-DOTA]-TOC activities may be associated with increasing hematological toxicities. The dose related hematotoxicity profile of [90Y-DOTA]-TOC could facilitate tailoring [90Y-DOTA]-TOC in patients with preexisting hematotoxicities. The results of the long-term outcome suggest that fractionated [90Y-DOTA]-TOC treatment might allow to reduce renal toxicity and to improve overall survival. (ClinicalTrials.gov number NCT00978211).

  6. Measurement of thermal diffusivity of depleted uranium metal microspheres

    Science.gov (United States)

    Humrickhouse-Helmreich, Carissa J.; Corbin, Rob; McDeavitt, Sean M.

    2014-03-01

    The high void space of nuclear fuels composed of homogeneous uranium metal microspheres may allow them to achieve ultra-high burnup by accommodating fuel swelling and reducing fuel/cladding interactions; however, the relatively low thermal conductivity of microsphere nuclear fuels may limit their application. To support the development of microsphere nuclear fuels, an apparatus was designed in a glovebox and used to measure the apparent thermal diffusivity of a packed bed of depleted uranium (DU) microspheres with argon fill in the void spaces. The developed Crucible Heater Test Assembly (CHTA) recorded radial temperature changes due to an initial heat pulse from a central thin-diameter cartridge heater. Using thermocouple positions and time-temperature data, the apparent thermal diffusivity was calculated. The thermal conductivity of the DU microspheres was calculated based on the thermal diffusivity from the CHTA, known material densities and specific heat capacities, and an assumed 70% packing density based on prior measurements. Results indicate that DU metal microspheres have very low thermal conductivity, relative to solid uranium metal, and rapidly form an oxidation layer even in a low oxygen environment. At 500 °C, the thermal conductivity of the DU metal microsphere bed was 0.431 ± 0.0560 W/m-K compared to the literature value of approximately 32 W/m-K for solid uranium metal.

  7. Measurement of thermal diffusivity of depleted uranium metal microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Humrickhouse-Helmreich, Carissa J., E-mail: carissahelmreich@tamu.edu [Texas A and M University, Department of Nuclear Engineering, 337 Zachry Engineering Center, 3133 TAMU, College Station, TX 77843 (United States); Corbin, Rob, E-mail: rcorbin@terrapower.com [TerraPower, LLC, 330 120th Ave NE, Suite 100, Bellevue, WA 98005 (United States); McDeavitt, Sean M., E-mail: mcdeavitt@tamu.edu [Texas A and M University, Department of Nuclear Engineering, 337 Zachry Engineering Center, 3133 TAMU, College Station, TX 77843 (United States)

    2014-03-15

    The high void space of nuclear fuels composed of homogeneous uranium metal microspheres may allow them to achieve ultra-high burnup by accommodating fuel swelling and reducing fuel/cladding interactions; however, the relatively low thermal conductivity of microsphere nuclear fuels may limit their application. To support the development of microsphere nuclear fuels, an apparatus was designed in a glovebox and used to measure the apparent thermal diffusivity of a packed bed of depleted uranium (DU) microspheres with argon fill in the void spaces. The developed Crucible Heater Test Assembly (CHTA) recorded radial temperature changes due to an initial heat pulse from a central thin-diameter cartridge heater. Using thermocouple positions and time–temperature data, the apparent thermal diffusivity was calculated. The thermal conductivity of the DU microspheres was calculated based on the thermal diffusivity from the CHTA, known material densities and specific heat capacities, and an assumed 70% packing density based on prior measurements. Results indicate that DU metal microspheres have very low thermal conductivity, relative to solid uranium metal, and rapidly form an oxidation layer even in a low oxygen environment. At 500 °C, the thermal conductivity of the DU metal microsphere bed was 0.431 ± 0.0560 W/m-K compared to the literature value of approximately 32 W/m-K for solid uranium metal.

  8. Measurement of thermal diffusivity of depleted uranium metal microspheres

    International Nuclear Information System (INIS)

    Humrickhouse-Helmreich, Carissa J.; Corbin, Rob; McDeavitt, Sean M.

    2014-01-01

    The high void space of nuclear fuels composed of homogeneous uranium metal microspheres may allow them to achieve ultra-high burnup by accommodating fuel swelling and reducing fuel/cladding interactions; however, the relatively low thermal conductivity of microsphere nuclear fuels may limit their application. To support the development of microsphere nuclear fuels, an apparatus was designed in a glovebox and used to measure the apparent thermal diffusivity of a packed bed of depleted uranium (DU) microspheres with argon fill in the void spaces. The developed Crucible Heater Test Assembly (CHTA) recorded radial temperature changes due to an initial heat pulse from a central thin-diameter cartridge heater. Using thermocouple positions and time–temperature data, the apparent thermal diffusivity was calculated. The thermal conductivity of the DU microspheres was calculated based on the thermal diffusivity from the CHTA, known material densities and specific heat capacities, and an assumed 70% packing density based on prior measurements. Results indicate that DU metal microspheres have very low thermal conductivity, relative to solid uranium metal, and rapidly form an oxidation layer even in a low oxygen environment. At 500 °C, the thermal conductivity of the DU metal microsphere bed was 0.431 ± 0.0560 W/m-K compared to the literature value of approximately 32 W/m-K for solid uranium metal

  9. Popcorn balls-like ZnFe{sub 2}O{sub 4}-ZrO{sub 2} microsphere for photocatalytic degradation of 2,4-dinitrophenol

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Xi [College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China); Liu, Yutang [Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha 410082 (China); Xia, Xinnian, E-mail: xnxia@hnu.edu.cn [College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China); Wang, Longlu [College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China); State Key Laboratory of Chemo/Biosensing and Chemometrics, Hunan University, Changsha 410082 (China)

    2017-06-15

    Highlights: • Popcorn balls-like microsphere photocatalyst. • High photocatalytic activity toward 2,4-DNP degradation. • Degradation kinetics, mechanism, active species were analyzed. • Excellent stable recycling performance. - Abstract: In this paper, novel popcorn balls-like ZnFe{sub 2}O{sub 4}-ZrO{sub 2} composite microspheres were successfully fabricated by a simple hydrothermal method. The morphology, structure and optical property of the microspheres were characterized. The microspheres were used as the photocatalysts to degrade 2,4-dinitrophenol, and exhibited superior photocatalytic performance. Under simulated solar visible light irradiation, the degradation rate of ZnFe{sub 2}O{sub 4}-ZrO{sub 2} photocatalyst (mass ratio of ZnFe{sub 2}O{sub 4}/ZrO{sub 2} = 2:1) was almost 7.4 and 2.4 times higher than those of pure ZnFe{sub 2}O{sub 4} and ZrO{sub 2}. The enhancement could attribute to stronger light absorption, lower carrier recombination and multi-porous structure of the microspheres. Moreover, the popcorn balls-like photocatalysts can be easily separated, because of the magnetism of the samples. After five times runs, the photocatalyst still showed 90% of its photocatalytic degradation efficiency. This work demonstrated a good prospect for removing organic pollutants in water.

  10. Monodisperse porous LiFePO4/C microspheres derived by microwave-assisted hydrothermal process combined with carbothermal reduction for high power lithium-ion batteries

    Science.gov (United States)

    Chen, Rongrong; Wu, Yixiong; Kong, Xiang Yang

    2014-07-01

    A microwave-assisted hydrothermal approach combined with carbothermal reduction has been developed to synthesize monodisperse porous LiFePO4/C microspheres, which possess the diameter range of 1.0-1.5 μm, high tap density of ∼1.3 g cm-3, and mesoporous characteristic with Brunauer-Emmett-Teller (BET) surface area of 30.6 m2 g-1. The obtained microspheres show meatball-like morphology aggregated by the carbon-coated LiFePO4 nanoparticles. The electrochemical impedance spectra (EIS) results indicate that carbon coating can effectively enhance both of the electronic and ionic conductivities for LiFePO4/C microspheres. The Li-ion diffusion coefficient of the LiFePO4/C microspheres calculated from the cyclic voltammetry (CV) curves is ∼6.25 × 10-9 cm2 s-1. The electrochemical performance can achieve about 100 and 90 mAh g-1 at 5C and 10C charge/discharge rates, respectively. As cathode material, the as-prepared LiFePO4/C microspheres show excellent rate capability and cycle stability, promising for high power lithium-ion batteries.

  11. Simple and efficient synthesis of copper(II)-modified uniform magnetic Fe3O4@SiO2 core/shell microspheres for immobilization of cellulase

    Science.gov (United States)

    Li, Shi-Kuo; Hou, Xiao-Cheng; Huang, Fang-Zhi; Li, Chuan-Hao; Kang, Wen-Juan; Xie, An-Jian; Shen, Yu-Hua

    2013-11-01

    In this paper, we reported a simple and efficient protocol for preparation of Cu2+-modified magnetic Fe3O4@SiO2 core/shell microspheres for immobilization of cellulase. The uniform magnetic Fe3O4@SiO2 core/shell microspheres with a thin shell of 20 nm were synthesized through a solvothermal method followed by a sol-gel process. An amino-terminated silane coupling agent of (3-aminopropyl)triethoxysilane (APTS) was then grafted on them for capturing Cu2+ ions. The reaction process is very simple, efficient, and economical. Noticeably, the content of Cu2+ ions on the magnetic core/shell microspheres can reach 4.6 Wt%, endowing them possess as high immobilization capacity as 225.5 mg/g for cellulase. And the immobilized cellulase can be retained over 90 % on the magnetic microspheres after six cycles. Meanwhile, the magnetic microspheres decorated with Cu2+ ions show a superparamagnetic character with a high magnetic saturation of 58.5 emu/g at room temperature, suggesting conveniently and rapidly recycle the enzyme from solution. This facile, recyclable, high immobilization capacity and activity strategy may find potential applications in enzyme catalytic reactions with low cost.

  12. Simple and efficient synthesis of copper(II)-modified uniform magnetic Fe3O4@SiO2 core/shell microspheres for immobilization of cellulase

    International Nuclear Information System (INIS)

    Li, Shi-Kuo; Hou, Xiao-Cheng; Huang, Fang-Zhi; Li, Chuan-Hao; Kang, Wen-Juan; Xie, An-Jian; Shen, Yu-Hua

    2013-01-01

    In this paper, we reported a simple and efficient protocol for preparation of Cu 2+ -modified magnetic Fe 3 O 4 @SiO 2 core/shell microspheres for immobilization of cellulase. The uniform magnetic Fe 3 O 4 @SiO 2 core/shell microspheres with a thin shell of 20 nm were synthesized through a solvothermal method followed by a sol–gel process. An amino-terminated silane coupling agent of (3-aminopropyl)triethoxysilane (APTS) was then grafted on them for capturing Cu 2+ ions. The reaction process is very simple, efficient, and economical. Noticeably, the content of Cu 2+ ions on the magnetic core/shell microspheres can reach 4.6 Wt%, endowing them possess as high immobilization capacity as 225.5 mg/g for cellulase. And the immobilized cellulase can be retained over 90 % on the magnetic microspheres after six cycles. Meanwhile, the magnetic microspheres decorated with Cu 2+ ions show a superparamagnetic character with a high magnetic saturation of 58.5 emu/g at room temperature, suggesting conveniently and rapidly recycle the enzyme from solution. This facile, recyclable, high immobilization capacity and activity strategy may find potential applications in enzyme catalytic reactions with low cost

  13. A review on target drug delivery: magnetic microspheres

    Directory of Open Access Journals (Sweden)

    Amit Chandna

    2013-01-01

    Magnetic microsphere is newer approach in pharmaceutical field. Magnetic microspheres as an alternative to traditional radiation methods which use highly penetrating radiation that is absorbed throughout the body. Its use is limited by toxicity and side effects. The aim of the specific targeting is to enhance the efficiency of drug delivery & at the same time to reduce the toxicity & side effects. This kind of delivery system is very much important which localises the drug to the disease site. In this larger amount of freely circulating drug can be replaced by smaller amount of magnetically targeted drug. Magnetic carriers receive magnetic responses to a magnetic field from incorporated materials that are used for magnetic microspheres are chitosan, dextran etc. magnetic microspheres can be prepared from a variety of carrier material. One of the most utilized is serum albumin from human or other appropriate species. Drug release from albumin microspheres can be sustained or controlled by various stabilization procedures generally involving heat or chemical cross-linking of the protein carrier matrix.

  14. Study on the source of optical activity: Pt. 6. ESR spectroscopy on the asymmetrical radical yields in 90Sr-90Y β irradiated D-and L-alanine

    International Nuclear Information System (INIS)

    Wang Wenqing; Zhao Jian; Ding Xiang

    1993-01-01

    Free radical formation in 90 Sr- 90 Y β irradiated D- and L-alanine is studied by ESR spectroscopy. To calibrate the probable differences in the size of ESR tubes, the different densities of alanine and the incidental different impurities, samples are firstly irradiated with 60 Co γ rays. Then the D- and L- alanine samples are irradiated with 90 Sr- 90 Y source at 77 K. Soon after irradiation, ESR measurement is performed on each sample. The average ratio H β+γ /H γ of D- alanine is 0.147 higher than that of L- alanine, indicating that more free radicals are induced in D- alanine by β irradiation. Irradiation at 77 K is capable of diminishing the effect of thermal movement on the polarization of β electrons and freezing the free radical formation. The experiments show the stereoselective interaction of β electrons with D- and L- amino acids, and so supports the Vester-ulbricht hypothesis

  15. Fluorine- and iron-modified hierarchical anatase microsphere photocatalyst for water cleaning: facile wet chemical synthesis and wavelength-sensitive photocatalytic reactivity.

    Science.gov (United States)

    Liu, Shaohong; Sun, Xudong; Li, Ji-Guang; Li, Xiaodong; Xiu, Zhimeng; Yang, He; Xue, Xiangxin

    2010-03-16

    High photocatalytic efficiency, easy recovery, and no biological toxicity are three key properties related to the practical application of anatase photocatalyst in water cleaning, but seem to be incompatible. Nanoparticles-constructed hierarchical anatase microspheres with high crystallinity and good dispersion prepared in this study via one-step solution processing at 90 degrees C under atmospheric pressure by using ammonium fluotitanate as the titanium source and urea as the precipitant can reconcile these three requirements. The hierarchical microspheres were found to grow via an aggregative mechanism, and contact recrystallization occurred at high additions of the FeCl(3) electrolyte into the reaction system. Simultaneous incorporation of fluorine and iron into the TiO(2) matrix was confirmed by combined analysis of X-ray diffraction, X-ray photoelectron spectroscopy, Fourier transform infrared spectroscopy, and UV-vis absorption spectroscopy. Surface structure and morphology changes of the microspheres induced by high-temperature annealing were clearly observed by field-emission scanning electron microscopy, especially for the phase-transformed particles. The original nanoparticles-constructed rough surfaces partially became smooth, resulting in a sharp drop in photocatalytic efficiency. Interestingly, iron loading has detrimental effects on the visible-light photocatalytic activity of both the as-prepared and the postannealed anatase microspheres but greatly enhances the photocatalytic activity of the as-prepared anatase microspheres under UV irradiation. No matter under UV or visible-light irradiation, the fluorine-loaded anatase microspheres and especially the postannealed ones show excellent photocatalytic performance. The underlying mechanism of fluorine and iron loading on the photocatalytic efficacy of the anatase microspheres was discussed in detail. Beyond photocatalytic applications, this kind of material is of great importance to the assembling of

  16. Growth of Gd{sub 2}O{sub 3} coherent layers on UO{sub 2} microsphere surface via sol-gel process

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Luciana S.; Silva, Edilaine F.; Oliveira, Felipe W.F.; Pereira, Yara S.; Brandão, Alisson F.C.; Santos, Ana Maria M.; Lameiras, Fernando S.; Reis, Sergio C.; Pedrosa, Tércio A.; Santos, Armindo, E-mail: santosa@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    In this work, we synthesized and characterized UO{sub 2}-Gd{sub 2}O{sub 3} nuclear fuel via three routes, aiming to solve the problems arising from the addition of Gd{sub 2}O{sub 3} in UO{sub 2} matrix. By the industrial route, the mixture of powders (UO{sub 2}, <90 μ and 6 wt% Gd{sub 2}O{sub 3} <10 μm) results in pellets with 91% TD at 1677 °C/H{sub 2}/4 h. By the mixed route, the formation of Gd{sub 2}O{sub 3} coherent layers on UO{sub 2} powder (particles <90 μ) and microsphere (225 μm) surface produced UO{sub 2} - 6 wt% Gd{sub 2}O{sub 3} pellets with 95% (powder; 1625 °C/H{sub 2}/4 hr) and 83% (microsphere; 1677°C/H{sub 2}/4 hr) TD. By the sol-gel route, we obtained UO{sub 2} - 6 wt% Gd{sub 2}O{sub 3} in a deagglomerated (powder; <70 μm) or agglomerated microsphere 232 μm) form whose pellets reached > 97% (powder) and >98% (microsphere) TI) at 1677 °C/H{sub 2}/4h. According to XRD, OM, and SEM/EDS analysis, the referred three routes do not form a complete solid solution of UO{sub 2}-Gd{sub 2}O{sub 3} at the temperatures and time of sintering used; Gd{sub 2}O{sub 3} granule islands are present in the pellets originating from these routes. The obtained results suggest that the topological arrangement and the deficient nanostructuring of UO{sub 2} and Gd{sub 2}O{sub 3} phases, either in the raw material (powder and microsphere) as in their compacts, are the cause of low densification and irregular distribution of Gd{sub 2}O{sub 3} in UO{sub 2} matrix; mixing of U and Gd at the molecular level does not form a solid solution; and the mixed route is a good alternative to the industrial route. (author)

  17. Beat frequency ultrasonic microsphere contrast agent detection system

    Science.gov (United States)

    Pretlow, III, Robert A. (Inventor); Yost, William T. (Inventor); Cantrell, Jr., John H. (Inventor)

    1997-01-01

    A system for and method of detecting and measuring concentrations of an ultrasonically-reflective microsphere contrast agent involving detecting non-linear sum and difference beat frequencies produced by the microspheres when two impinging signals with non-identical frequencies are combined by mixing. These beat frequencies can be used for a variety of applications such as detecting the presence of and measuring the flow rates of biological fluids and industrial liquids, including determining the concentration level of microspheres in the myocardium.

  18. Microwave Irradiation Assisted Preparation of Chitosan Composite Microsphere for Dye Adsorption

    Directory of Open Access Journals (Sweden)

    Xiaoyu Chen

    2017-01-01

    Full Text Available Chitosan-activated carbon composite microspheres were prepared by emulsion cross-linking method and its adsorption properties for methyl orange were studied. Chitosan solution was mixed with activated carbon powder and then chitosan was cross-linked by epichlorohydrin under microwave irradiation. SEM photos show that the composite microspheres have diameters of 200–400 μm and activated carbon powder dispersed on the surface of composite microsphere. FTIR spectrum indicates chitosan is successfully cross-linked. Microwave irradiation can effectively shorten the cross-linking time. Composite microspheres have enhanced dye adsorption capacity for methyl orange compared to chitosan microspheres. Kinetic studies showed that the adsorption followed a pseudo-second-order model. Isotherm studies show that the isotherm adsorption equilibrium is better described by Freundlich isotherm. Regeneration results show that adsorption capacity of composite microsphere decreased about 5.51% after being reused for three times. These results indicated that chitosan-activated carbon composite microsphere has potential application in the removal of dye from wastewaters.

  19. Development and Evaluation of Isoniazid Loaded Silk Fibroin Microsphere

    Directory of Open Access Journals (Sweden)

    Narinder Singh

    Full Text Available Aim: Current experimental investigation is dedicated to prepare microspheres with small size and good sphericity by Phase Separation method using Isoniazid (INH as model drug. Silk fibroin has unique intrinsic qualities like biodegradability, biocompatibility or release properties and their tunable drug loading capacity. The delivery loading proficiency of the drug molecules in silk spheres be contingent on their charge, and hydrophobicity or subsequent in altered drug release profiles. Methods: In the present work Isoniazid loaded silk fibroin microsphere was prepared by using phase separation method. Microsphere was evaluated for Ultraviolet-visible spectroscopy, Fourier Transform infrared spectroscopy, Entrapment efficiency, Scanning electron microscopy Studies. Results: Scanning electron microscopy studies revealed that Isoniazid Loaded Silk Fibroin Microspheres were spherical. Entrapment Efficiency of Isoniazid loaded Microspheres of different Formulation from F1 to F5 was in range of 53 to 68 %. F3 showed 68.47 % entrapment Efficiency and the optimized formulation drug release was 93.56 % at 24 hours. Conclusion: Experimental report disclosed a new aqueous based formulation method for silk spheres with controllable shape or size and sphere. Isoniazid loaded silk microspheres may act as ideal nano formulation with elaborated studies.

  20. Synthesis and characterization of Supeparamagnetics Microspheres (PMMA via suspension polymerization

    Directory of Open Access Journals (Sweden)

    Paulo Emilio Feuser

    2014-02-01

    Full Text Available Magnetics nanoparticles (NPMs has found many applications in biomedical and technological areas. The objective of this work is the preparation and characterization of PMMA microspheres containing NPMs coated with oleic acid (NPMs-AO. For the preparation of MNPs-AO was used the coprecipitation method in an aqueous medium. For the preparation of the superparamagnetic microspheres used in suspension polymerization technique. The microspheres showed a size distribution particles of approximately 150um and a spherical morphology. From the analysis of gel permeation chromatography (GPC determined the number average molecular weight (Mw of the magnetics microspheres and there was a variation in the Mw depending on the concentration of MNPs-AO in this reaction. To analyze the magnetic properties used the vibrating sample magnetometer (MAV. The microspheres showed superparamagnetic properties and a value of saturation magnetization (Ms of about 8 emu/g MNPs. Therefore you can conclude that it is possible to obtain superparamagnetics microspheres for a particular application, either, biomedical or technological.

  1. Efficacy of Radiation Synovectomy with Y-90 in chronic knee joint synovitis

    International Nuclear Information System (INIS)

    Roiz, C.; Raigoso, P.; Suarez, J.P.; Llana, B.; Zeidan, N.; Dominguez, M.L.; Bernardo, L.; Fernandez, J.A.; Nunez, R.

    2002-01-01

    Aim: To evaluate the efficiency of Radiation Synovectomy (RSO) with Y-90 in knee joints of patients with chronic synovitis (CS) resistant to classical conventional therapy, and assess its long-term prognosis. Material and Methods: 22 patients (7 males,15 females, mean age 50, range 12-81) with CS of the knees, of a duration ranging from 2 to 48 years, were included in the study. All patients had suffered from CS for more than 6 months, and were resistant to anti-inflammatory drugs, immunosuppressants and intraarticular (IA) steroid therapy. The cases included:10 patients with rheumatoid arthritis (RA), 5 psoriatic arthritis (PA), 3 pigmented villonodular synovitis, 2 seronegative oligo-polyarthritis and 2 chronic mono arthritis. We used an IA dose of 3 to 5 mCi (37-185 MBq)of Y-90. The effect of the therapy with Y-90 on 22 knees was evaluated from 3 to 12 months after the RSO. Patients' response was assess and classified according to the results of plain radiology and following conventional rheumatological criteria as: A) Excellent (E) with a visual improvement (VI) of 80-100mm, no pain in motion, little or no palpable swelling, no inflammation; B) Good (G) VI of 60-90mm, minimal pain in motion, little palpable swelling; C) Mild (M) VI of 20-59mm, moderate reduction of pain, obvious swelling; D) Bad (B) VI of only 0-19 mm, no changes or an increase of pain in the swollen joints. Results: The response observed was classified as: E in 5 patients (23%); G in 10 patients (45%); M in 3 patients (14%); and B in 4(18%). The 4 patients with a response B, had all of them joint erosion on plain radiology. Furthermore, one of the patients was a failure from prior surgical synovectomy (SS). The other 3 patients subsequently had SS. In contrast, all the responses E and G were obtained exclusively in patients with RA or PA. No short or long-term adverse side effects were noted. Conclusion: RSO is an effective treatment for patients with persistent CS, specially in RA and PA. The

  2. Mobilization of microspheres from a fractured soil during intermittent infiltration events

    Science.gov (United States)

    Mohanty, Sanjay; Bulicek, Mark; Metge, David W.; Harvey, Ronald W.; Ryan, Joseph N.; Boehm, Alexandria B.

    2015-01-01

    Pathogens or biocolloids mobilized in the vadose zone may consequently contaminate groundwater. We found that microspheres were mobilized from a fractured soil during intermittent rainfall and the mobilization was greater when the microsphere size was larger and when the soil had greater water permeability.The vadose zone filters pathogenic microbes from infiltrating water and consequently protects the groundwater from possible contamination. In some cases, however, the deposited microbes may be mobilized during rainfall and migrate into the groundwater. We examined the mobilization of microspheres, surrogates for microbes, in an intact core of a fractured soil by intermittent simulated rainfall. Fluorescent polystyrene microspheres of two sizes (0.5 and 1.8 mm) and Br− were first applied to the core to deposit the microspheres, and then the core was subjected to three intermittent infiltration events to mobilize the deposited microspheres. Collecting effluent samples through a 19-port sampler at the base of the core, we found that water flowed through only five ports, and the flow rates varied among the ports by a factor of 12. These results suggest that flow paths leading to the ports had different permeabilities, partly due to macropores. Although 40 to 69% of injected microspheres were retained in the core during their application, 12 to 30% of the retained microspheres were mobilized during three intermittent infiltration events. The extent of microsphere mobilization was greater in flow paths with greater permeability, which indicates that macropores could enhance colloid mobilization during intermittent infiltration events. In all ports, the 1.8-mm microspheres were mobilized to a greater extent than the 0.5-mm microspheres, suggesting that larger colloids are more likely to mobilize. These results are useful in assessing the potential of pathogen mobilization and colloid-facilitated transport of contaminants in the subsurface under natural infiltration

  3. {sup 18}F-FDG PET independently predicts survival in patients with cholangiocellular carcinoma treated with {sup 90}Y microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Haug, Alexander R. [Ludwig-Maximilians-University, Department of Nuclear Medicine, Munich (Germany); Klinikum Grosshadern, Department of Nuclear Medicine, Munich (Germany); Heinemann, Volker [Ludwig-Maximilians-University, Department of Internal Medicine III, Munich (Germany); Bruns, Christiane J. [Ludwig-Maximilians-University, Department of Surgery, Munich (Germany); Hoffmann, Ralf; Jakobs, Tobias [Ludwig-Maximilians-University, Institute of Clinical Radiology, Munich (Germany); Bartenstein, Peter; Hacker, Marcus [Ludwig-Maximilians-University, Department of Nuclear Medicine, Munich (Germany)

    2011-06-15

    {sup 90}Y radioembolization has emerged as a valuable therapy for intrahepatic cholangiocellular carcinomas (ICC). We aimed to evaluate the prognostic power of FDG PET/CT and that of pretherapeutic scintigraphy with {sup 99m}Tc-labelled macroagglutinated albumin (MAA), an index of tumour vascularization. The study group comprised 26 consecutive patients suffering from nonresectable ICC. Before treatment with radioembolization, all patients underwent MRI of the liver, as well as MAA scintigraphy, which was followed immediately by SPECT(/CT) to quantify the liver-lung shunt fraction. Using image fusion, regions of interest were drawn around the tumours and the entire liver, and the tumour-to-liver quotient was calculated. In addition, FDG PET/CT was performed at baseline and 3 months after radioembolization, and the percentage changes in peak ({delta}SUV{sub max}) and mean ({delta}SUV{sub mean}) FDG uptake and in metabolic tumour volume ({delta}Vol{sub 2SD}) relative to baseline were calculated. Treatment response at 3 months was also assessed using contrast-enhanced MRI and CT on the basis of standard criteria. Of 23 patients in whom follow-up MRI was available, 5 (22%) showed a partial response, 15 (65%) stable disease and 3 (13%) progressive disease. The change in all FDG values significantly predicted survival by Kaplan-Meier analysis after radioembolization; {delta}Vol{sub 2SD} responders had a median survival of 97 weeks versus 30 weeks in nonresponders (P = 0.02), whereas {delta}SUV{sub max} and {delta}SUV{sub mean} responders had a median survival of 114 weeks (responder) versus 19 weeks (nonresponder) and 69 weeks in patients with stable disease (P < 0.05). Pretherapeutic MAA scintigraphy or MRI did not predict survival, nor did the presence of extrahepatic metastases, or prior therapies. Only {delta}Vol{sub 2SD} was significantly associated with survival by univariate analysis (hazard ratio 0.25; P = 0.04) and multivariate analysis (hazard ratio 0.20, P = 0

  4. Radioembolization for the treatment of unresectable hepatocellular carcinoma: A clinical review

    Institute of Scientific and Technical Information of China (English)

    Saad M Ibrahim; Robert J Lewandowski; Kent T Sato; Vanessa L Gates; Laura Kulik; Mary F Mulcahy; Robert K Ryu; Reed A Omary; Riad Salem

    2008-01-01

    Hepatocellular carcinoma (HCC) is the sixth most common cancer in the world. The majority of patients with HCC present with unresectable disease. These patients have historically had limited treatment options secondary to HCC demonstrating chemoresistance to the currently available systemic therapies. Additionally, normal liver parenchyma has shown intolerance to tumoricidal radiation doses, limiting the use of external beam radiation. Because of these limitations, novel percutaneous liver-directed therapies have emerged. The targeted infusion of radioactive microspheres (radioembolization) represents one such therapy. Radioembolization is a minimally invasive transcatheter therapy through which radioactive microspheres are infused into the hepatic arteries that supply tumor. Once infused, these microspheres traverse the hepatic vascular plexus and selectively implant within the tumor arterioles. Embedded within the arterioles, the 90Y impregnated microspheres emit high energy and low penetrating radiation doses selectively to the tumor. Radioembolization has recently shown promise for the treatment of patients with unresectable HCC. The objective of this review article is to highlight twocurrently available radioembolic devices (90Y, 188Rh) and provide the reader with a recent review of the literature.

  5. Progress in Preparation of Monodisperse Polymer Microspheres

    Science.gov (United States)

    Zhang, Hongyan

    2017-12-01

    The monodisperse crosslinked polymer microspheres have attracted much attention because of their superior thermal and solvent resistance, mechanical strength, surface activity and adsorption properties. They are of wide prospects for using in many fields such as biomedicine, electronic science, information technology, analytical chemistry, standard measurement and environment protection etc. Functional polymer microspheres prepared by different methods have the outstanding surface property, quantum size effect and good potential future in applications with its designable structure, controlled size and large ratio of surface to volume. Scholars of all over the world have focused on this hot topic. The preparation method and research progress in functional polymer microspheres are addressed in the paper.

  6. Rapid determination of 90Sr in seawater

    International Nuclear Information System (INIS)

    Pavlotskaya, F.I.; Moskin, A.I.

    1994-01-01

    A method for determining 90 Sr in seawater that is based on direct isolation and radiochemical purification of daughter 90 Y is proposed. The analysis time is 6-8 h. The chemical yield of the Y-carrier during the 90 Sr determination from 35 liters of seawater varies in the range 37-69%. The analysis uncertainty is 90 Sr from seawater and subsequent isolation of 90 Y

  7. Dosimetric comparison of {sup 90}Y, {sup 32}P, and {sup 186}Re radiocolloids in craniopharyngioma treatments

    Energy Technology Data Exchange (ETDEWEB)

    Sadeghi, Mahdi; Karimi, Elham; Hosseini, S. Hamed [Agricultural, Medical and Industrial Research School, Nuclear Science and Technology Research Institute, P.O. Box 31485/498, Karaj (Iran, Islamic Republic of); Faculty of Engineering, Research and Science Campus, Islamic Azad University, P.O. Box 14155/4933, Tehran (Iran, Islamic Republic of)

    2009-11-15

    Purpose: In the radionuclide treatment of some forms of brain tumors such as craniopharyngiomas, the selection of the appropriate radionuclide for therapy is a key element in treatment planning. The aim was to study the influence by considering the beta-emitter radionuclide dose rate in an intracranial cyst. Methods: Dosimetry was performed using the MCNP4C radiation transport code. Analytical dosimetry was additionally performed using the Loevinger and the Berger formulas in the MATLAB software. Each result was compared under identical conditions. The advantages and disadvantages of using {sup 90}Y versus {sup 32}P and {sup 186}Re were investigated. Results: The dose rate at the inner surface of the cyst wall was estimated to be 400 mGy/h for a 1 MBq/ml concentration of {sup 90}Y. Under identical conditions of treatment, the corresponding dose rates were 300 mGy/h for {sup 32}P and 160 mGy/h for {sup 186}Re. For a well-defined cyst radius and identical wall thickness, higher dose rates resulted for {sup 90}Y. Conclusions: To achieve the same radiological burden, the required amount of physical activity of injectable solution is lower for {sup 32}P. This is found to be a consequence of both the radionuclide physical half-life and the pattern of energy deposition from the emitted radiation. According to the half-life and dose-rate results, {sup 90}Y would be a good substitute for {sup 32}P.

  8. Treatment of unresectable primary and metastatic liver cancer with yttrium-90 microspheres (TheraSphere): assessment of hepatic arterial embolization.

    Science.gov (United States)

    Sato, Kent; Lewandowski, Robert J; Bui, James T; Omary, Reed; Hunter, Russell D; Kulik, Laura; Mulcahy, Mary; Liu, David; Chrisman, Howard; Resnick, Scott; Nemcek, Albert A; Vogelzang, Robert; Salem, Riad

    2006-01-01

    In Canada and Europe, yttrium-90 microspheres (TheraSphere); MDS Nordion, Ottawa, Canada) are a primary treatment option for primary and secondary hepatic malignancies. We present data from 30 patients with hepatocellular carcinoma (HCC) and metastatic liver disease treated with TheraSphere from a single academic institution to evaluate the angiographically evident embolization that follows treatment. Seven interventional radiologists from one treatment center compared pretreatment and posttreatment angiograms. The reviewers were blinded to the timing of the studies. The incidence of postembolization syndrome (PES) was determined as well as objective tumor response rates by the World Health Organization (WHO), Response Evaluation Criteria in Solid Tumors (RECIST), and European Association for the Study of the Liver (EASL) criteria. There were 420 independent angiographic observations that were assessed using the chi-squared statistic. The pretreatment and posttreatment angiograms could not be correctly identified on average more than 43% of the time (p = 0.0004). The postprocedure arterial patency rate was 100%. The objective tumor response rates for all patients were 24%, 31%, and 72% for WHO, RECIST, and EASL criteria, respectively. All of the patients tolerated the procedure without complications and were treated on an outpatient basis, and four patients had evidence of PES. This treatment method does not result in macroscopic embolization of the hepatic arteries, thereby maintaining hepatic tissue perfusion. These data support the principle that the favorable response rates reported with TheraSphere are likely due to radiation and microscopic embolization rather than flow-related macroscopic embolization and ischemia.

  9. Quality of life in patients diagnosed with primary hepatocellular carcinoma: hepatic arterial infusion of Cisplatin versus 90-Yttrium microspheres (Therasphere).

    Science.gov (United States)

    Steel, Jennifer; Baum, Andrew; Carr, Brian

    2004-02-01

    The aims of the study were to test the difference in health-related quality (HRQL) of life and survival in patients diagnosed with primary hepatocellular carcionma (HCC) and treated with either hepatic arterial infusion (HAI) of Cisplatin or 90-Yttrium microspheres (Therasphere). The design of the study was a non-randomized parallel cohort study. Twenty-eight patients participated in the present study. HRQL was assessed by administration of the Functional Assessment of Cancer Therapy-Hepatobiliary. Survival was measured using Kaplan Meier methods. The results of present study suggest treatment with Therasphere) had an advantage in regard to HRQL and survival when compared to Cisplatin. At 3-month follow-up, patients who were treated with Therasphere had a higher level of functional well-being as well as overall quality of life when compared to patients treated with Cisplatin. At 6-month follow-up patients (treated with Therasphere) continued to have better functional well-being when compared to patients being treated with HAI of Cisplatin. At 6-month follow-up, survival was found to be similar for patients treated with Therasphere when compared to patients being treated with Cisplatin. Preliminary data suggest that treatment with Therasphere has a modest advantage in regard to HRQL when compared patients treated with HAI of Cisplatin. Future research with Therasphere, that includes a larger sample size and longer follow-up, is necessary to make definitive conclusions regarding the efficacy and effect on HRQL. Copyright 2003 John Wiley & Sons, Ltd.

  10. Low dose preoperative radiotherapy for carcinoma of the oesophagus

    International Nuclear Information System (INIS)

    Arnott, S.J.; Duncan, W.; Kerr, G.R.; Jack, W.J.L.; Mackillop, W.J.; Walbaum, P.R.; Cameron, E.

    1992-01-01

    Patients (176) with potentially operable squamous cell carcinoma or adenocarcinoma of middle or lower thirds of oesophagus were randomly assigned to preoperative radiotherapy or surgery alone. Patients assigned to the radiotherapy arm received 20 Gy in 10 treatments over 2 weeks, using parallel opposed 4 MV beams. The preoperative radiotherapy was not associated with any significant acute morbidity or any increase in operative complications. The median survival of the overall group of 176 patients was 8 moths, and the 5-year survival was 13%. There was no significant difference in the survival of the 90 patients who received preoperative radiotherapy and the 86 who were managed by surgery alone. Proportional hazards analysis identified lymph node involvement, high tumor grade and male sex as significant adverse prognostic features, but the treatment option assigned had no prognostic significance. It was concluded that low dose preoperative radiotherapy offered no advantage over surgery alone. (author). 9 refs.; 3 figs.; 6 tabs

  11. Microsphere formation in droplets using antisolvent vapour precipitation technique

    OpenAIRE

    Chew, Sean Jun Liang

    2017-01-01

    In previous studies, the antisolvent vapour precipitation method has been proven to produce uniformly sized lactose microspheres (1.0 µm) from a single droplet (1.2 mm diameter) at atmospheric pressure. These types of particles have potential applications in the pharmaceutical industry, especially due to their high dissolution rate. This project looked into the possibility of using antisolvent vapour precipitation to produce microspheres from finely atomised droplets. Microspheres in the sub-...

  12. Solvent/Non-Solvent Sintering To Make Microsphere Scaffolds

    Science.gov (United States)

    Laurencin, Cato T.; Brown, Justin L.; Nair, Lakshmi

    2011-01-01

    A solvent/non-solvent sintering technique has been devised for joining polymeric microspheres to make porous matrices for use as drug-delivery devices or scaffolds that could be seeded with cells for growing tissues. Unlike traditional sintering at elevated temperature and pressure, this technique is practiced at room temperature and pressure and, therefore, does not cause thermal degradation of any drug, protein, or other biochemical with which the microspheres might be loaded to impart properties desired in a specific application. Also, properties of scaffolds made by this technique are more reproducible than are properties of comparable scaffolds made by traditional sintering. The technique involves the use of two miscible organic liquids: one that is and one that is not a solvent for the affected polymer. The polymeric microspheres are placed in a mold having the size and shape of the desired scaffold, then the solvent/non-solvent mixture is poured into the mold to fill the void volume between the microspheres, then the liquid mixture is allowed to evaporate. Some of the properties of the resulting scaffold can be tailored through choice of the proportions of the liquids and the diameter of the microspheres.

  13. Treatment with tandem [90Y]DOTA-TATE and [177Lu]DOTA-TATE of neuroendocrine tumours refractory to conventional therapy.

    Science.gov (United States)

    Seregni, E; Maccauro, M; Chiesa, C; Mariani, L; Pascali, C; Mazzaferro, V; De Braud, F; Buzzoni, R; Milione, M; Lorenzoni, A; Bogni, A; Coliva, A; Lo Vullo, S; Bombardieri, E

    2014-02-01

    Peptide receptor radionuclide therapy (PRRT) with radiolabelled somatostatin analogues has been demonstrated to be an effective therapeutic option in patients with disseminated neuroendocrine tumours (NET). Treatment with tandem [(90)Y]DOTA-TATE and [(177)Lu]DOTA-TATE may improve the efficacy of PRRT without increasing the toxicity. In a phase II study we evaluated the feasibility of combined PPRT with a high-energy beta emitter ((90)Y) and a medium-energy beta/gamma emitter ([(177)Lu) in patients with metastatic NET refractory to conventional therapy. A group of 26 patients with metastatic NET were treated with four therapeutic cycles of alternating [[(177)Lu]DOTA-TATE (5.55 GBq) and [(90)Y]DOTA-TATE (2.6 GBq). A dosimetric evaluation was carried out after administration of [[(177)Lu]DOTA-TATE to calculate the absorbed doses in healthy organs. The acute and long-term toxicities of repeated treatment were analysed. PRRT efficacy was evaluated according to RECIST. Administration of tandem [(90)Y]DOTA-TATE and [[(177)Lu]DOTA-TATE induced objective responses in 42.3 % of patients with metastatic NET with a median progression-free survival longer than 24 months. Of patients with pretreatment carcinoid syndrome, 90 % showed a symptomatic response or a reduction in tumour-associated pain. The cumulative biologically effective doses (BED) were below the toxicity limit in the majority of patients, in the absence of renal function impairment. The results of our study indicates that combined [(90)Y]DOTA-TATE and [(177)Lu]DOTA-TATE therapy is a feasible and effective therapeutic option in NET refractory to conventional therapy. Furthermore, the absence of kidney damage and the evaluated cumulative BEDs suggest that increasing the number of tandem administrations is an interesting approach.

  14. Sindicatos y centrales sindicales en Brasil en los años 80 y 90

    Directory of Open Access Journals (Sweden)

    Alvaro A. COMIN

    2009-11-01

    Full Text Available RESUMEN: El objetivo de este artículo es realizar un balance de la trayectoria de las principales centrales sindicales brasileñas en esta última década y media y reflexionar sobre los límites y posibilidades existentes para su efectiva consolidación como organismos centralizados de representación de los intereses de los trabajadores. En primer lugar, el artículo menciona algunas diferencias que separan la experiencia de la formación de las centrales sindicales en los países desarrollados y en Brasil. Posteriormente se analizan el proceso de formación de las centrales sindicales, los principales clivages que determinan la división del movimiento sindical en el inicio de los años 80 y la trayectoria de las principales centrales a lo largo de aquella década. En el siguiente punto, se presenta un cuadro corporativo de las dos principales centrales (CUT y FS que polarizan la escena en los años 90. Finalmente, se concluye con algunas especulaciones sobre las posibilidades de cambio en el interior del cuadro jurídico-institucional que regula la actual estructura de las relaciones capital-trabajo y de la organización sindical en Brasil y sus consecuencias en términos de consolidación de las centrales sindicales.ABSTRACT: The goal of this article is to make a historical balance of the main brazilean trade unions in the last ten years. The author deals about its possibilities to fit its function: to represent the interest of workers. At first time, it is mentioned some differences between the experiences of brazilean trade unionsand the european ones. Then, the author analyzes the process of formation and history of brazilean trade unions and the main cleavages of these ones during the eighties. The next item is a comparative analysis of the two main trade unions (CUT an FS during the nineties. Finally, the article finishes with some reflections about the possibilities of change within the rules between capital and work in Brazil.

  15. XPS analysis of aluminosilicate microspheres bioactivity tested in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Todea, M.; Vanea, E. [Faculty of Physics and Institute of Interdisciplinary Research on Bio-Nano-Sciences, Babes Bolyai University, Cluj-Napoca 400084 (Romania); Bran, S. [University of Medicine and Pharmacy “Iuliu Haţieganu”, Department of Cranio-Maxillofacial Surgery, 400029 Cluj-Napoca (Romania); Berce, P. [Technical University of Cluj-Napoca, Faculty of Machine Building and National Centre of Rapid Prototyping, 400641 Cluj-Napoca (Romania); Simon, S., E-mail: simons@phys.ubbcluj.ro [Faculty of Physics and Institute of Interdisciplinary Research on Bio-Nano-Sciences, Babes Bolyai University, Cluj-Napoca 400084 (Romania)

    2013-04-01

    The study aims to characterize surface properties of aluminosilicate microspheres incorporating yttrium, with potential biomedical applications. Micrometric particles of spherical shape were obtained by spray drying method. The behavior of aluminosilicate microspheres without yttrium and with yttrium was investigated under in vitro conditions, by seven days incubation in simulated body fluid (SBF). The surface elemental composition and the atomic environments on outermost layer of the microspheres, prior to and after incubation in SBF were evaluated by X-ray photoelectron spectroscopy (XPS) in order to investigate their bioactivity. The results were analyzed to underline the effect of yttrium addition on surface properties of the aluminosilicate microspheres and implicitly on the behavior of the samples in simulated body environments.

  16. Microspheres with an ultra high holmium content for brachytherapy of malignancies

    International Nuclear Information System (INIS)

    Lira, Raphael A.; Myamoto, Douglas M.; Souza, Jaime R.; Nascimento, Nanci; Azevedo, Mariangela de Burgos M. de; Osso Junior, Joao A.; Martinelli, Jose R.

    2011-01-01

    The overall objective of this work is to develop biodegradable microspheres intended for internal radiation therapy which provides an improved treatment for hepatic carcinomas. The most studied brachytherapy system employing microspheres made of holmium-biopolymer system is composed by poly(L-lactic acid) (PLLA) and holmium acetylacetonate (HoAcAc). The importance of the holmium high content in the microspheres can be interpreted as follow from a therapeutic standpoint, to achieve an effective use of microspheres loaded with HoAcAc, a high content of holmium is required to yield enough radioactivity with a relatively low amount of microspheres.The usual amounts of holmium that are incorporated in the microspheres composed by poly(L-lactic acid) and HoAcAc are 17.0 ± 0.5% (w/w) of holmium, which corresponds to a loading of about 50% of HoAcAc. Different approaches have been investigated to increase that value. One updated approach towards this direction is the production of microspheres with ultrahigh holmium as matrix using HoAcAc crystals as the sole starting material without the use of biopolymer. Likewise, in the search of microspheres with increased holmium content , it has been demonstrated that by changing the HoAcAc crystal structure by its recrystallization from crystal phase to the amorphous there is lost of acetylacetonate and water molecules causing the increasing of the holmium content. Microspheres were prepared by solvent evaporation, using holmium acetylacetonate (HoAcAc) crystals as the sole ingredient. Microspheres were characterized by using light and scanning electron microscopy, infrared and Raman spectroscopy, differential scanning calorimetry, X-rays diffraction, and confocal laser scanning microscopy. (author)

  17. Microspheres with an ultra high holmium content for brachytherapy of malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Lira, Raphael A.; Myamoto, Douglas M.; Souza, Jaime R.; Nascimento, Nanci; Azevedo, Mariangela de Burgos M. de [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Biotecnologia; Osso Junior, Joao A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Radiofarmacia; Martinelli, Jose R. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Ciencias e Tecnologia de Materiais

    2011-07-01

    The overall objective of this work is to develop biodegradable microspheres intended for internal radiation therapy which provides an improved treatment for hepatic carcinomas. The most studied brachytherapy system employing microspheres made of holmium-biopolymer system is composed by poly(L-lactic acid) (PLLA) and holmium acetylacetonate (HoAcAc). The importance of the holmium high content in the microspheres can be interpreted as follow from a therapeutic standpoint, to achieve an effective use of microspheres loaded with HoAcAc, a high content of holmium is required to yield enough radioactivity with a relatively low amount of microspheres.The usual amounts of holmium that are incorporated in the microspheres composed by poly(L-lactic acid) and HoAcAc are 17.0 {+-} 0.5% (w/w) of holmium, which corresponds to a loading of about 50% of HoAcAc. Different approaches have been investigated to increase that value. One updated approach towards this direction is the production of microspheres with ultrahigh holmium as matrix using HoAcAc crystals as the sole starting material without the use of biopolymer. Likewise, in the search of microspheres with increased holmium content , it has been demonstrated that by changing the HoAcAc crystal structure by its recrystallization from crystal phase to the amorphous there is lost of acetylacetonate and water molecules causing the increasing of the holmium content. Microspheres were prepared by solvent evaporation, using holmium acetylacetonate (HoAcAc) crystals as the sole ingredient. Microspheres were characterized by using light and scanning electron microscopy, infrared and Raman spectroscopy, differential scanning calorimetry, X-rays diffraction, and confocal laser scanning microscopy. (author)

  18. Preparation and Comparative Bioavailability Studies of Indomethacin-Loaded Cetyl Alcohol Microspheres

    Directory of Open Access Journals (Sweden)

    N. Vishal Gupta

    2013-01-01

    Full Text Available The purpose of the present study was to compare the in vitro release and to find out whether the bioavailability of a 75 mg indomethacin capsule (Microcid SR was equivalent to optimized formulation (indomethacin-loaded cetyl alcohol microspheres. Indomethacin-loaded cetyl alcohol microspheres were prepared by meltable emulsified cooling-induced technique. Surface morphology of microspheres has been evaluated using scanning electron microscopy. A single dose, randomized, complete cross over study of IM microspheres was carried out on 10 healthy male and female Albino sheep’s under fasting conditions. The plasma was separated and the concentrations of the drug were determined by HPLC-UV method. Plasma indomethacin concentrations and other pharmacokinetic parameters obtained were statistically analyzed. The SEM images revealed the spherical shape of fat microspheres, and more than 98.0% of the isolated microspheres were in the size range 12–32 μm. DSC, FTIR spectroscopy and stability studies indicated that the drug after encapsulation with fat microspheres was stable and compatible. Both formulations were found to be bioequivalent as evidenced by in vivo studies. Based on this study, it can be concluded that cetyl alcohol microspheres and Microcid SR capsule are bioequivalent in terms of the rate and extent of absorption.

  19. Blood Transfusion Requirement and Not Preoperative Anemia Are Associated with Perioperative Complications Following Intracorporeal Robot-Assisted Radical Cystectomy.

    Science.gov (United States)

    Tan, Wei Shen; Lamb, Benjamin W; Khetrapal, Pramit; Tan, Mae-Yen; Tan, Melanie El; Sridhar, Ashwin; Cervi, Elizabeth; Rodney, Simon; Busuttil, Gerald; Nathan, Senthil; Hines, John; Shaw, Greg; Mohammed, Anna; Baker, Hilary; Briggs, Timothy P; Klein, Andrew; Richards, Toby; Kelly, John D

    2017-02-01

    To assess the prevalence of preoperative anemia and the impact of preoperative anemia and blood transfusion requirement on 30- and 90-day complications in a cohort of patients undergoing robot-assisted radical cystectomy with intracorporeal urinary diversion (iRARC). IRARC was performed on 166 patients between June 2011 and March 2016. Prospective data were collected for patient demographics, clinical and pathologic characteristics, perioperative variables, transfusion requirements, and hospital length of stay. Thirty- and 90-day complications were classified according to the modified Memorial Sloan Kettering Cancer Center Clavien-Dindo system. Preoperative anemia was common (43.4%) and greatest in patients receiving neoadjuvant chemotherapy (48.6%) (p blood transfusion (p = 0.001). Blood transfusion required in 20.4% of patients with intraoperative and postoperative blood transfusion rate was 10.2% and 13.9%, respectively. The 30-day all complication rate and 30-day major complication rate were 55.4% and 15.7%, respectively, while 90-day all complication rate and 90-day major complication rate were 65.7% and 19.3%, respectively. Intraoperative blood transfusion was not associated with increased complications, but postoperative blood transfusion requirement was independently associated with perioperative morbidity: all 30-day complications (p = 0.003), all 90-day complications (p = 0.009), and 90-day major complications (p = 0.004). The presence of preoperative anemia in patients undergoing iRARC is not associated with increased surgical risk, although preoperative anemic patients were significantly more likely to require blood transfusion. Blood transfusion requirement and specifically postoperative blood transfusion are independently associated with perioperative morbidity and are an important factor for the optimization of postoperative outcomes.

  20. Application of superparamagnetic microspheres for affinity adsorption and purification of glutathione

    International Nuclear Information System (INIS)

    Wang Qiang; Guan Yueping; Yang Mingzhu

    2012-01-01

    The superparamagnetic poly-(MA–DVB) microspheres with micron size were synthesized by the modified suspension polymerization method. Adsorption of glutathione by magnetic poly-(MA–DVB) microspheres with IDA-copper was investigated. The effect of solution pH value, affinity adsorption and desorption of glutathione was studied. The results showed that the optimum pH value for glutathione adsorption was found at pH=3.5, the maximum capacity for glutathione of magnetic poly-(MA–DVB) microspheres was estimated at 42.4 mg/g by fitting the experimental data to the Langmuir equation. The adsorption equilibrium of glutathione was obtained in about 10 min and the adsorbed glutathione was desorbed from the magnetic microspheres in about 30 min using NaCl buffer solution. The magnetic microspheres could be repeatedly utilized for the affinity adsorption of glutathione. - Highlights: ► The magnetic microsphere with surface IDA–Cu groups was synthesized. ► The magnetic microspheres were applied for adsorption of GSH. ► The adsorption–desorption of glutathione was investigated. ► The maximum adsorption capacity of GSH was fitted at 42.4 mg/g.

  1. Do Mixed-Flora Preoperative Urine Cultures Matter?

    Science.gov (United States)

    Polin, Michael R; Kawasaki, Amie; Amundsen, Cindy L; Weidner, Alison C; Siddiqui, Nazema Y

    2017-06-01

    To determine whether mixed-flora preoperative urine cultures, as compared with no-growth preoperative urine cultures, are associated with a higher prevalence of postoperative urinary tract infections (UTIs). This was a retrospective cohort study. Women who underwent urogynecologic surgery were included if their preoperative clean-catch urine culture result was mixed flora or no growth. Women were excluded if they received postoperative antibiotics for reasons other than treatment of a UTI. Women were divided into two cohorts based on preoperative urine culture results-mixed flora or no growth; the prevalence of postoperative UTI was compared between cohorts. Baseline characteristics were compared using χ 2 or Student t tests. A logistic regression analysis then was performed. We included 282 women who were predominantly postmenopausal, white, and overweight. There were many concomitant procedures; 46% underwent a midurethral sling procedure and 68% underwent pelvic organ prolapse surgery. Preoperative urine cultures resulted as mixed flora in 192 (68%) and no growth in 90 (32%) patients. Overall, 14% were treated for a UTI postoperatively. There was no difference in the proportion of patients treated for a postoperative UTI between the two cohorts (25 mixed flora vs 13 no growth, P = 0.77). These results remained when controlling for potentially confounding variables in a logistic regression model (adjusted odds ratio 0.92, 95% confidence interval 0.43-1.96). In women with mixed-flora compared with no-growth preoperative urine cultures, there were no differences in the prevalence of postoperative UTI. The clinical practice of interpreting mixed-flora cultures as negative is appropriate.

  2. Feasibility of temporary protective embolization of normal liver tissue using degradable starch microspheres during radioembolization of liver tumours

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Carsten [University of Bonn, Department of Radiology, Bonn (Germany); Pieper, Claus Christian; Wilhelm, Kai E.; Schild, Hans Heinz [University of Bonn, Department of Radiology, Bonn (Germany); Ezziddin, Samer; Ahmadzadehfar, Hojjat [University of Bonn, Department of Nuclear Medicine, Bonn (Germany)

    2014-02-15

    To describe a new approach to protect nontarget healthy liver tissue using degradable starch microspheres (DSM) as a short-term embolizate during radioembolization of liver tumours with {sup 90}Y microspheres. Between December 2011 and July 2012 radioembolization was performed in 54 patients. Five of these patients (three women, two men; mean age 67 years) underwent protective temporary embolization using DSM (EmboCept {sup registered} S) of normal liver tissue that could not be excluded from the area treated by radioembolization through catheter repositioning. Clinical symptoms, laboratory findings, preinterventional imaging, and {sup 99m}Tc-MAA and bremsstrahlung SPECT/CT, as well as baseline and follow-up imaging with {sup 18}F-FDG PET/CT and MRI, were evaluated in relation to the technical and clinical success of the protective embolization. Temporary embolization of arteries supplying normal liver tissue using DSM was technically successful in all five patients. {sup 99m}Tc-MAA SPECT/CT performed in the first two patients after DSM injection showed no increased pulmonary shunting compared to the MAA test injection without DSM. Bremsstrahlung SPECT/CT after radioembolization demonstrated satisfactory irradiation of the tumour and successful protection of normal liver tissue. There were only mild hepatotoxic effects (grade 1) on laboratory follow-up examinations, and no adverse events associated with DSM embolization or radioembolization were recorded. Temporary embolization with DSM before radioembolization is feasible and can effectively protect areas of normal liver tissue from irradiation and avoid permanent embolization if other methods such as catheter repositioning are not possible due to the location of the metastases. (orig.)

  3. Feasibility of temporary protective embolization of normal liver tissue using degradable starch microspheres during radioembolization of liver tumours

    International Nuclear Information System (INIS)

    Meyer, Carsten; Pieper, Claus Christian; Wilhelm, Kai E.; Schild, Hans Heinz; Ezziddin, Samer; Ahmadzadehfar, Hojjat

    2014-01-01

    To describe a new approach to protect nontarget healthy liver tissue using degradable starch microspheres (DSM) as a short-term embolizate during radioembolization of liver tumours with 90 Y microspheres. Between December 2011 and July 2012 radioembolization was performed in 54 patients. Five of these patients (three women, two men; mean age 67 years) underwent protective temporary embolization using DSM (EmboCept registered S) of normal liver tissue that could not be excluded from the area treated by radioembolization through catheter repositioning. Clinical symptoms, laboratory findings, preinterventional imaging, and 99m Tc-MAA and bremsstrahlung SPECT/CT, as well as baseline and follow-up imaging with 18 F-FDG PET/CT and MRI, were evaluated in relation to the technical and clinical success of the protective embolization. Temporary embolization of arteries supplying normal liver tissue using DSM was technically successful in all five patients. 99m Tc-MAA SPECT/CT performed in the first two patients after DSM injection showed no increased pulmonary shunting compared to the MAA test injection without DSM. Bremsstrahlung SPECT/CT after radioembolization demonstrated satisfactory irradiation of the tumour and successful protection of normal liver tissue. There were only mild hepatotoxic effects (grade 1) on laboratory follow-up examinations, and no adverse events associated with DSM embolization or radioembolization were recorded. Temporary embolization with DSM before radioembolization is feasible and can effectively protect areas of normal liver tissue from irradiation and avoid permanent embolization if other methods such as catheter repositioning are not possible due to the location of the metastases. (orig.)

  4. Surface modification of cyclomatrix polyphosphazene microsphere by thiol-ene chemistry and lectin recognition

    International Nuclear Information System (INIS)

    Chen, Chen; Zhu, Xue-yan; Gao, Qiao-ling; Fang, Fei; Huang, Xiao-jun

    2016-01-01

    Graphical abstract: A new synthetic route leading to polyphosphazene cyclomatrix microsphere with various functional groups has achieved via thiol-ene click modification. Herein, hexacholorocyclophosphazene (HCCP) crosslinked with bisphenol-S and 4,4′-diallyl bisphenol-S to generate broadly dispersed microspheres. Thiol-ene modification under UV irradiation not only presented high efficiency and flexibility for post-functionalization, but also imposed no harm on global morphology and crosslinked skeleton of such microspheres. - Highlights: • Functional polyphosphazene microspheres with high chemical flexibility were synthesized by thiol-ene modification. • Polyphosphazene microspheres possessed high thermal stability. • Glycosylated polyphosphazene microspheres showed affinity to lectin Con-A, which inferred potential application in biomedicine. - Abstract: A new synthetic route leading to functional polyphosphazene cyclomatrix microsphere has been developed via thiol-ene click modification. Hexacholorocyclophosphazene (HCCP) was crosslinked with both bisphenol-S and 4,4′-diallyl bisphenol-S to obtain vinyl polyphosphazene microspheres (VPZM) in order to ensure high crosslinking degree and introduce vinyl moieties. Compared to the microspheres obtained by HCCP and bisphenol-S, the size of VPZM was broadly dispersed from 400 nm to 1.40 μm. Thiol-ene click reactions were carried out to attach functional groups, such as glucosyl, carboxyl, ester and dodecyl groups onto polyphosphazene microspheres, which demonstrated no change in morphology and size after modification. Solid state NMR (SSNMR) and Fourier transform infrared spectoscopy (FT-IR) results showed that the vinyl moieties were introduced in the period of crosslinking and functionalization was also successful via click reactions. Moreover, the microspheres presented a little difference in thermal properties after modification. Concanavalin A (Con-A) fluorescent adsorption was also observed for

  5. Surface modification of cyclomatrix polyphosphazene microsphere by thiol-ene chemistry and lectin recognition

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chen; Zhu, Xue-yan; Gao, Qiao-ling; Fang, Fei; Huang, Xiao-jun, E-mail: hxjzxh@zju.edu.cn

    2016-11-30

    Graphical abstract: A new synthetic route leading to polyphosphazene cyclomatrix microsphere with various functional groups has achieved via thiol-ene click modification. Herein, hexacholorocyclophosphazene (HCCP) crosslinked with bisphenol-S and 4,4′-diallyl bisphenol-S to generate broadly dispersed microspheres. Thiol-ene modification under UV irradiation not only presented high efficiency and flexibility for post-functionalization, but also imposed no harm on global morphology and crosslinked skeleton of such microspheres. - Highlights: • Functional polyphosphazene microspheres with high chemical flexibility were synthesized by thiol-ene modification. • Polyphosphazene microspheres possessed high thermal stability. • Glycosylated polyphosphazene microspheres showed affinity to lectin Con-A, which inferred potential application in biomedicine. - Abstract: A new synthetic route leading to functional polyphosphazene cyclomatrix microsphere has been developed via thiol-ene click modification. Hexacholorocyclophosphazene (HCCP) was crosslinked with both bisphenol-S and 4,4′-diallyl bisphenol-S to obtain vinyl polyphosphazene microspheres (VPZM) in order to ensure high crosslinking degree and introduce vinyl moieties. Compared to the microspheres obtained by HCCP and bisphenol-S, the size of VPZM was broadly dispersed from 400 nm to 1.40 μm. Thiol-ene click reactions were carried out to attach functional groups, such as glucosyl, carboxyl, ester and dodecyl groups onto polyphosphazene microspheres, which demonstrated no change in morphology and size after modification. Solid state NMR (SSNMR) and Fourier transform infrared spectoscopy (FT-IR) results showed that the vinyl moieties were introduced in the period of crosslinking and functionalization was also successful via click reactions. Moreover, the microspheres presented a little difference in thermal properties after modification. Concanavalin A (Con-A) fluorescent adsorption was also observed for

  6. Development and Evaluation of Floating Microspheres of Curcumin ...

    African Journals Online (AJOL)

    Purpose: To prepare and evaluate floating microspheres of curcumin for prolonged gastric residence time and increased drug bioavailability. Methods: Floating microsphere were prepared by emulsion solvent diffusion method, using hydroxylpropyl methylcellulose (HPMC), ethyl cellulose (EC), Eudragit S 100 polymer in ...

  7. Microspheres of poly(ε-caprolactone) loaded Holmium-165: morphology and thermal degradation behavior

    International Nuclear Information System (INIS)

    Geraldes, Adriana Napoleao; Miyamoto, Douglas Massao; Lira, Raphael Arivar de; Osso Junior, Joao Alberto; Nascimento, Nanci; Azevedo, Mariangela de Burgos M. de

    2011-01-01

    Polycaprolactone (PCL), being one of the most important biocompatible and biodegradable aliphatic polyester, provides many potential biomedical. The preparation of biodegradable materials, polymer-based microspheres, is being developed by our group and the goal is to prepare and label with Ho-165 different polymer-based microspheres. The use of radionuclide-loaded microspheres is a promising treatment of liver malignancies. PCL microspheres can be loaded with holmium acetylacetonate (HoAcAc). PCL and PCL/HoAcAc microspheres were prepared by an emulsion solvent extraction/evaporation technique. The PCL/ HoAcAc microspheres were irradiated in a nuclear reactor IEA-R1 at IPEN/CNEN-SP to radionuclide activation. Gamma irradiation was performed at 25 and 50 kGy doses. The microspheres were evaluated by differential scanning calorimetry analysis (DSC), thermogravimetric analysis (TG), Fourier transformed infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and con focal laser scanning microscopy (CLSM). In the CLSM images were observed emission in 488 nm characteristic of holmium. The SEM surface image of PCL/HoAcAc microspheres showed more roughness than PCL microspheres. TG of PCL/HoAcAc microspheres showed a substantial weight loss above 200 degree C, indicating decomposition of HoAcAc. The residual weight indicates the presence of Ho 2 O 3 . Gamma irradiation at 25 and 50 kGy doses had no effect on the PCL/HoAcAc microspheres, which indicates that the chemical composition of the microspheres had not change. (author)

  8. Microspheres of poly({epsilon}-caprolactone) loaded Holmium-165: morphology and thermal degradation behavior

    Energy Technology Data Exchange (ETDEWEB)

    Geraldes, Adriana Napoleao; Miyamoto, Douglas Massao; Lira, Raphael Arivar de; Osso Junior, Joao Alberto; Nascimento, Nanci; Azevedo, Mariangela de Burgos M. de [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    Polycaprolactone (PCL), being one of the most important biocompatible and biodegradable aliphatic polyester, provides many potential biomedical. The preparation of biodegradable materials, polymer-based microspheres, is being developed by our group and the goal is to prepare and label with Ho-165 different polymer-based microspheres. The use of radionuclide-loaded microspheres is a promising treatment of liver malignancies. PCL microspheres can be loaded with holmium acetylacetonate (HoAcAc). PCL and PCL/HoAcAc microspheres were prepared by an emulsion solvent extraction/evaporation technique. The PCL/ HoAcAc microspheres were irradiated in a nuclear reactor IEA-R1 at IPEN/CNEN-SP to radionuclide activation. Gamma irradiation was performed at 25 and 50 kGy doses. The microspheres were evaluated by differential scanning calorimetry analysis (DSC), thermogravimetric analysis (TG), Fourier transformed infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and con focal laser scanning microscopy (CLSM). In the CLSM images were observed emission in 488 nm characteristic of holmium. The SEM surface image of PCL/HoAcAc microspheres showed more roughness than PCL microspheres. TG of PCL/HoAcAc microspheres showed a substantial weight loss above 200 degree C, indicating decomposition of HoAcAc. The residual weight indicates the presence of Ho{sub 2}O{sub 3}. Gamma irradiation at 25 and 50 kGy doses had no effect on the PCL/HoAcAc microspheres, which indicates that the chemical composition of the microspheres had not change. (author)

  9. Receptor-mediated radionuclide therapy with 90Y-DOTATOC in association with amino acid infusion: a phase I study

    International Nuclear Information System (INIS)

    Bodei, Lisa; Zoboli, Stefania; Grana, Chiara; Bartolomei, Mirco; Rocca, Paola; Caracciolo, Maurizio; Chinol, Marco; Paganelli, Giovanni; Cremonesi, Marta; Maecke, Helmut R.

    2003-01-01

    The aim of this study was to determine the maximum tolerated dose of 90 Y-DOTATOC per cycle administered in association with amino acid solution as kidney protection in patients with somatostatin receptor-positive tumours. Forty patients in eight groups received two cycles of 90 Y-DOTATOC, with activity increased by 0.37 GBq per group, starting at 2.96 and terminating at 5.55 GBq. All patients received lysine ± arginine infusion immediately before and after therapy. Forty-eight percent developed acute grade I-II gastrointestinal toxicity (nausea and vomiting) after amino acid infusion whereas no acute adverse reactions occurred after 90 Y-DOTATOC injection up to 5.55 GBq/cycle. Grade III haematological toxicity occurred in three of seven (43%) patients receiving 5.18 GBq, which was defined as the maximum tolerable activity per cycle. Objective therapeutic responses occurred. Five GBq per cycle is the recommended dosage of 90 Y-DOTATOC when amino acids are given to protect the kidneys. Although no patients developed acute kidney toxicity, delayed kidney toxicity remains a major concern, limiting the cumulative dose to 25 Gy. The way forward with this treatment would seem to be to identify more effective renal protective agents, in order to be able to increase the cumulative injectable activity and hence tumour dose. (orig.)

  10. Effect of Fabrication Process Parameters on the Size of Gelatin/Nanohydroxyapatite Microspheres

    Directory of Open Access Journals (Sweden)

    S. Bagheri-Khoulenjani

    2009-12-01

    Full Text Available Nano-hydroxyapatite/gelatin (nHA/Ge microspheres are currently used in bone tissue engineering as bone filler. In this  study, the effect of fabrication process parameters on the particle size of nano-hydroxyapatite/gelatinmicrospheres was investigated. The nHA/Ge microspheres were fabricated using water in oil emulsion. In order to design an experimental design, a surface response model with 2 factors including the rate of shaking and water to oil volume ratio in 3 levels was applied. Particle size was evaluated by using an optical microscope. The morphology of microspheres and distribution of nano-particles within the microspheres were studied by using scanning electron microscope and Ca elemental map obtained from energy dispersive X-ray analysis (EDX, respectively. Statistical analysis of the results obtained from particle size measurements revealed that the rate of shaking has stronger influence on the particle size of microspheres. Morphological studies showed that the fabricated microspheres were spherical with smooth surface. Ca elemental map of the microspheres showed that nano-hydroxyapatite particles distributed uniformly within the microspheres.

  11. Somatostatin-based radiotherapy with [90Y-DOTA]-TOC in neuroendocrine tumors: long-term outcome of a phase I dose escalation study

    Directory of Open Access Journals (Sweden)

    Marincek Nicolas

    2013-01-01

    Full Text Available Abstract Background We describe the long-term outcome after clinical introduction and dose escalation of somatostatin receptor targeted therapy with [90Y-DOTA]-TOC in patients with metastasized neuroendocrine tumors. Methods In a clinical phase I dose escalation study we treated patients with increasing [90Y-DOTA]-TOC activities. Multivariable Cox regression and competing risk regression were used to compare efficacy and toxicities of the different dosage protocols. Results Overall, 359 patients were recruited; 60 patients were enrolled for low dose (median: 2.4 GBq/cycle, range 0.9-7.8 GBq/cycle, 77 patients were enrolled for intermediate dose (median: 3.3 GBq/cycle, range: 2.0-7.4 GBq/cycle and 222 patients were enrolled for high dose (median: 6.7 GBq/cycle, range: 3.7-8.1 GBq/cycle [90Y-DOTA]-TOC treatment. The incidences of hematotoxicities grade 1–4 were 65.0%, 64.9% and 74.8%; the incidences of grade 4/5 kidney toxicities were 8.4%, 6.5% and 14.0%, and the median survival was 39 (range: 1–158 months, 34 (range: 1–118 months and 29 (range: 1–113 months. The high dose protocol was associated with an increased risk of kidney toxicity (Hazard Ratio: 3.12 (1.13-8.59 vs. intermediate dose, p = 0.03 and a shorter overall survival (Hazard Ratio: 2.50 (1.08-5.79 vs. low dose, p = 0.03. Conclusions Increasing [90Y-DOTA]-TOC activities may be associated with increasing hematological toxicities. The dose related hematotoxicity profile of [90Y-DOTA]-TOC could facilitate tailoring [90Y-DOTA]-TOC in patients with preexisting hematotoxicities. The results of the long-term outcome suggest that fractionated [90Y-DOTA]-TOC treatment might allow to reduce renal toxicity and to improve overall survival. (ClinicalTrials.gov number NCT00978211.

  12. Somatostatin-based radiotherapy with [90Y-DOTA]-TOC in neuroendocrine tumors: long-term outcome of a phase I dose escalation study

    Science.gov (United States)

    2013-01-01

    Background We describe the long-term outcome after clinical introduction and dose escalation of somatostatin receptor targeted therapy with [90Y-DOTA]-TOC in patients with metastasized neuroendocrine tumors. Methods In a clinical phase I dose escalation study we treated patients with increasing [90Y-DOTA]-TOC activities. Multivariable Cox regression and competing risk regression were used to compare efficacy and toxicities of the different dosage protocols. Results Overall, 359 patients were recruited; 60 patients were enrolled for low dose (median: 2.4 GBq/cycle, range 0.9-7.8 GBq/cycle), 77 patients were enrolled for intermediate dose (median: 3.3 GBq/cycle, range: 2.0-7.4 GBq/cycle) and 222 patients were enrolled for high dose (median: 6.7 GBq/cycle, range: 3.7-8.1 GBq/cycle) [90Y-DOTA]-TOC treatment. The incidences of hematotoxicities grade 1–4 were 65.0%, 64.9% and 74.8%; the incidences of grade 4/5 kidney toxicities were 8.4%, 6.5% and 14.0%, and the median survival was 39 (range: 1–158) months, 34 (range: 1–118) months and 29 (range: 1–113) months. The high dose protocol was associated with an increased risk of kidney toxicity (Hazard Ratio: 3.12 (1.13-8.59) vs. intermediate dose, p = 0.03) and a shorter overall survival (Hazard Ratio: 2.50 (1.08-5.79) vs. low dose, p = 0.03). Conclusions Increasing [90Y-DOTA]-TOC activities may be associated with increasing hematological toxicities. The dose related hematotoxicity profile of [90Y-DOTA]-TOC could facilitate tailoring [90Y-DOTA]-TOC in patients with preexisting hematotoxicities. The results of the long-term outcome suggest that fractionated [90Y-DOTA]-TOC treatment might allow to reduce renal toxicity and to improve overall survival. Trial registration ClinicalTrials.gov number:NCT00978211 PMID:23320604

  13. Evaluation of nonradioactive, colored microspheres for measurement of regional myocardial blood flow in dogs

    International Nuclear Information System (INIS)

    Hale, S.L.; Alker, K.J.; Kloner, R.A.

    1988-01-01

    Measurement of regional myocardial blood flow (RMBF) is crucial in experimental studies of myocardial ischemia and reperfusion in dogs. The standard measurement technique uses radioactive microspheres; however, not all institutions are able to dispose of radioactive waste and therefore cannot make use of this method. We tested a new, nonradioactive microsphere, labeled with colors instead of nuclides. Simultaneous blood flow measurements with two nuclide-labeled and two colored microspheres were performed after coronary occlusion in dogs. Both techniques show a within-method correlation of r greater than 0.98. Duplicate variability for paired RMBF values in 80 samples was 8.7 +/- 0.1% when computed with radioactive microspheres and 13.2 +/- 1.8% when computed with colored microspheres. There was a good correlation in the measurement of RMBF between the radioactive- and colored-microsphere methods (r = 0.98). The best-fitting linear regression line was expressed by the formula: Colored-microsphere RMBF = 1.11 (radioactive-microsphere RMBF)-0.02. When measured by colored microspheres, RMBF was approximately 8% higher than when computed with radioactive microspheres for blood flow values of 0-2 ml/min/g. When blood flow was increased pharmacologically to levels of 2-7.5 ml/min/g, colored microspheres yielded blood flow values 39% higher than the values computed by radioactive microspheres. We conclude that the nonradioactive, colored-microsphere method correlates with the radioactive technique, but at high flows, it yields values greater than those obtained with radioactive microspheres

  14. The synthesis and photocatalytic activity of ZnSe microspheres

    International Nuclear Information System (INIS)

    Cao Huaqiang; Xiao Yujiang; Zhang Sichun

    2011-01-01

    This paper reports the synthesis of semiconductor ZnSe microspheres composed of nanoparticles via a solvothermal route between the organic molecule selenophene (C 4 H 4 Se) and ZnCl 2 without adding any surfactant. The ZnSe microspheres were characterized by x-ray diffraction (XRD), Raman spectroscopy, scanning electron microscopy (SEM), field emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM), high resolution transmission electron microscopy (HRTEM), specific surface area measurement, and photoluminescence (PL) spectra. A strong and broad blue PL emission at 443 nm in wavelength (∼2.79 eV in photon energy) is attributed to the near-band-edge (NBE) emission of ZnSe, while the 530 nm peak is a defect-related (DL) emission. The photocatalytic activity of the as-prepared ZnSe microspheres was evaluated by photodegradation of methyl orange (MO) dye under ultraviolet (UV) light and visible light irradiation. The degradations of MO reach 94% or 95.1%, close to 100%, in the presence of the as-synthesized ZnSe microspheres or commercial ZnSe powder after 7 or 10 h under UV irradiation, respectively. Meanwhile the degradations of MO reach 94.3% or 60.6% in the presence of the as-synthesized ZnSe microspheres or commercial ZnSe powder after 12 h, respectively. The degradation rate of ZnSe microspheres is twice that of ZnSe commercial powder under UV light irradiation, and three times under visible light irradiation. The degradation process of MO dye on ZnSe microspheres under UV or visible light is also discussed.

  15. S values at voxels level for 188Re and 90Y calculated with the MCNP-4C code

    International Nuclear Information System (INIS)

    Coca, M.A.; Torres, L.A.; Cornejo, N.; Martin, G.

    2008-01-01

    Full text: MIRD formalism at voxel level has been suggested as an optional methodology to perform internal radiation dosimetry calculation during internal radiation therapy in Nuclear Medicine. Voxel S values for Y 90 , 131 I, 32 P, 99m Tc and 89 Sr have been published to different sizes. Currently, 188 Re has been proposed as a promising radionuclide for therapy due to its physical features and availability from generators. The main objective of this work was to estimate the voxel S values for 188 Re at cubical geometry using the MCNP-4C code for the simulations of radiation transport and energy deposition. Mean absorbed dose to target voxels per radioactive decay in a source voxel were estimated and reported for 188 Re and Y 90 . A comparison of voxel S values computed with the MCNP code and the data reported in MIRD Pamphlet 17 for 90 Y was performed in order to evaluate our results. (author)

  16. Facile preparation of hierarchically porous polymer microspheres for superhydrophobic coating

    Science.gov (United States)

    Gao, Jiefeng; Wong, Julia Shuk-Ping; Hu, Mingjun; Li, Wan; Li, Robert. K. Y.

    2013-12-01

    A facile method, i.e., nonsolvent assisted electrospraying, is proposed to fabricate hierarchically porous microspheres. The pore size on the microsphere surface ranges from a few tens to several hundred nanometers. Thermally and nonsolvent induced phase separation as well as breath figure is responsible for the formation of the hierarchical structures with different nano-sized pores. The nonsolvent could not only induce phase separation, but also stabilize the interface between the droplet and air, which can prevent the droplet from strong deformation, and is therefore beneficial to the formation of regular and uniform microspheres. On the other hand, solvent evaporation, polymer diffusion and Coulomb fission during electrospraying influence the morphology of finally obtained products. In this paper, the influence of polymer concentration, the weight ratio between nonsolvent and polymer and the flowing rate on the morphology of the porous microsphere is carefully studied. The hierarchically porous microsphere significantly increases the surface roughness and thus the hydrophobicity, and the contact angle can reach as high as 152.2 +/- 1.2°. This nonsolvent assisted electrospraying opens a new way to fabricate superhydrophobic coating materials.A facile method, i.e., nonsolvent assisted electrospraying, is proposed to fabricate hierarchically porous microspheres. The pore size on the microsphere surface ranges from a few tens to several hundred nanometers. Thermally and nonsolvent induced phase separation as well as breath figure is responsible for the formation of the hierarchical structures with different nano-sized pores. The nonsolvent could not only induce phase separation, but also stabilize the interface between the droplet and air, which can prevent the droplet from strong deformation, and is therefore beneficial to the formation of regular and uniform microspheres. On the other hand, solvent evaporation, polymer diffusion and Coulomb fission during

  17. Magnetic propulsion of microspheres at liquid-glass interfaces

    Science.gov (United States)

    Helgesen, Geir

    2018-02-01

    Bio-coated, magnetic microspheres have many applications in biotechnology and medical technology as a tool to separate and extract cells or molecules in a water solution by applying external strong magnetic field gradients. However, magnetic microspheres with or without attached cargo can also be separated in the liquid solution if they are exposed to alternating or rotating, relatively weak magnetic fields. Microspheres that have a higher density than the liquid will approach the bottom surface of the sample cell, and then a combination of viscous and surface frictional forces can propel the magnetic microspheres along the surface in a direction perpendicular to the axis of field rotation. Experiments demonstrating this type of magnetic propulsion are shown, and the forces active in the process are discussed. The motion of particles inside sample cells that were tilted relative to the horizontal direction was studied, and the variation of propulsion velocity as a function of tilt angle was used to find the values of different viscous and mechanical parameters of motion. Propulsion speeds of up to 5 μm/s were observed and were found to be caused by a partly rolling and partly slipping motion of rotating microspheres with a slipping coefficient near 0.6.

  18. Tomographic bremsstrahlung imaging with yttrium-90 in the context of radioembolisation of liver tumors; Tomografische Bildgebung mit Yttrium-90-Bremsstrahlung im Rahmen der Radioembolisation von Lebertumoren

    Energy Technology Data Exchange (ETDEWEB)

    Grosser, Oliver Stephan

    2013-04-12

    Establish tomographic Bremsstrahlung SPECT imaging (BSPECT) for the clinical validation of Selective Internal Radiotherapy (SIRT) with Yttrium-90 ({sup 90}Y) labelled microspheres. Various energy ranges (75 ± 3.8 keV; 135 ± 6.8 keV; 167 ± 8.4 keV) and the summation window were studied to see if they were suitable for BSPECT. To this end, clinically available reconstruction techniques were analysed for their suitability for BSPECT. The tomographic examinations were performed on a cylindrical phantom filled with spheres of different diameters d = [28; 35; 40; 50; 60] mm in a non-active waterfilled background. The spheres were filled with identical {sup 90}Y activity concentration (AC). Measurements were conducted at AC = [14.58; 5.20; 1.98; 0.66] MBq/cm{sup 3}. The BSPECT were reconstructed with filtered back-projection (FBP), a 2D Ordered-Subset Expectation Maximisation Algorithm (2D-OSEM) and a 3D Geometric Mean Algorithm (3D-GMA). Evaluation was made visually and on the basis of objective performance parameters such as contrast, signal-to-noise ratio (SNR) and image noise. While the 75 keV ± 3.8 keV window was identified as suitable for the BSPECT, limitations were revealed as to use of different implementations of the Point Spread Function (PSF). It was found for all reconstruction techniques that, at a given sphere diameter, there existed a linear relationship between the AC in the spheres and the reconstructed pulse rate per volume element. The recovery effect was verified for small spheres. The iterative techniques were found to be suitable for the BSPECT at all AC. At low AC, the 3D-GMA exhibited the least noise and the highest SNR. The FBP turned out to be entirely inappropriate for the BSPECT. The narrow energy window in which the bremsstrahlung interferes with the characteristic X-radiation of lead can be used for BSPECT. In this approach, the tomographic data reconstructed with different algorithms exhibited a varying image quality, with the iterative

  19. Comparative study on DOTA-derivatized bombesin analog labeled with 90Y and 177Lu: in vitro and in vivo evaluation

    International Nuclear Information System (INIS)

    Koumarianou, Eftychia; Mikolajczak, Renata; Pawlak, Dariusz; Zikos, Xhristos; Bouziotis, Pinelopi; Garnuszek, Piotr; Karczmarczyk, Urszula; Maurin, Michal; Archimandritis, Spyridon C.

    2009-01-01

    Introduction: The aim of the study was to compare in vitro and in vivo a novel DOTA-chelated bombesin (BN) analog of the amino acid sequence, QRLGNQWAVGHLM-CONH 2 (BN[2-14]NH 2 ), labeled with 90 Y and 177 Lu, for its potential use in targeted radiotherapy of tumors expressing gastrin releasing peptide (GRP) receptors. The same amino acid sequence, but with different chelator, referred as BN1.1 (Gly-Gly-Cys-Aca-QRLGNQWAVGHLM-CONH 2 ), has already been studied and reported; however, the DOTA-chelated one, suitable for labeling with M +3 type radiometals, was not yet described. Methods: The conditions for labeling of DOTA-BN[2-14]NH 2 with noncarrier added 90 Y and with 177 Lu [specific activity (SA), 15 Ci/mg Lu] were investigated and optimized to provide 90 Y-DOTA-BN[2-14]NH 2 and 177 Lu-DOTA-BN[2-14]NH 2 of high SA. The stability of the radiolabeled compounds in human serum was evaluated over a period of 24 h. The human prostate cancer cell line PC-3, known to express GRP receptors, was used for in vitro evaluation of radiolabeled peptide affinity to GRP receptors and for assessment of cytotoxicity of both nonlabeled and radiolabeled peptide. Biodistribution accompanied by receptor blocking was studied in normal Swiss mice. Results: 90 Y-DOTA-BN[2-14]NH 2 and 177 Lu-DOTA-BN[2-14]NH 2 were obtained with radiochemical yield >98% and high SA (67.3 GBq 90 Y/μmol and 33.6 GBq 177 Lu/μmol, respectively). They were stable when incubated in human serum for up to 24 h. The binding affinities of DOTA-BN[2-14]NH 2 and both nat Y- and nat Lu-labeled analogs to GRP receptors were high (IC 50 =1.78, 1.99, and 1.34 nM, respectively), especially for the nat Lu-DOTA-BN[2-14]NH 2 complex. The cytotoxicity study of DOTA-BN[2-14]NH 2 to PC-3 cells revealed an IC 50 =6300 nM after 72 h of exposition, while the labeled derivatives showed no significant cytotoxic effect. The internalization rate to PC-3 cells was more rapid for 177 Lu-labeled peptide (84.87%) than for the 90 Y

  20. Study on Magnetic Responsibility of Rare Earth Ferrite/Polyacrylamide Magnetic Microsphere

    Institute of Scientific and Technical Information of China (English)

    Zhang Ming; Wang Zhifeng; Zhang Hong; Dai Shaojun; Qiu Guanming; Okamoto Hiroshi

    2005-01-01

    In inverse microemulsion, rare earth ferrite/polyacrylamide magnetic microsphere were prepared and their magnetic responsibility were studied by magnetic balance. Results indicate that the magnetic responsibility of microsphere relates to magnetic moment of rare earth ion, and it can be improved by the addition of dysprosium ion of high magnetic moment. Dysprosium content has an effect on magnetic responsibility of dysprosium ferrite/polyacrylamide magnetic microsphere. The microsphere displays strong magnetic responsibility when the molar ratio of Dy3+/iron is 0.20.

  1. A dosimetric treatment planning strategy in radioembolization of hepatocarcinoma with 90Y glass microspheres.

    Science.gov (United States)

    Chiesa, C; Mira, M; Maccauro, M; Romito, R; Spreafico, C; Sposito, C; Bhoori, S; Morosi, C; Pellizzari, S; Negri, A; Civelli, E; Lanocita, R; Camerini, T; Bampo, C; Carrara, M; Seregni, E; Marchianò, A; Mazzaferro, V; Bombardieri, E

    2012-12-01

    Our goal was to limit liver toxicity and to obtain good efficacy by developing a dosimetric treatment planning strategy. While several dosimetric evaluations are reported in literature, the main problem of the safety of the treatment is rarely addressed. Our work is the first proposal of a treatment planning method for glass spheres, including both liver toxicity and efficacy issues. Fifty-two patients (series 1) had been treated for intermediated/advanced hepatocellular carcinoma (HCC) with glass spheres, according to the Therasphere® prescription of 120 Gy averaged on the injected lobe. They were retrospectively evaluated with voxel dosimetry, adopting the local deposition hypothesis. Regions of interest on tumor and non tumor parenchyma were drawn to determine the parenchyma absorbed dose, averaged also on non irradiated voxels, excluding tumor voxels. The relationship between the mean non tumoral parenchyma absorbed dose D and observed liver decompensation was analyzed. Basal Child-Pugh strongly affected the toxicity incidence, which was 22% for A5, 57% for A6, 89% for B7 patients. Restricting the analysis to our numerically richest class (basal Child-Pugh A5 patients), D median values were significantly different between toxic (median 90 Gy) and non toxic treatments (median 58 Gy) at a Mann-Withney test, (P=0.033). Using D as a marker for toxicity, the separation of the two populations in terms of area under ROC curve was 0.75, with 95% C.I. of [0.55-0.95]. The experimental Normal Tissue Complication Probability (NTCP) curve as a function of D resulted in the following values: 0%, 14%, 40%, 67% for D interval of [0-35] Gy, [35-70] Gy, [70-105] Gy, [105-140] Gy. A limit of about 70 Gy for the mean absorbed dose to parenchyma was assumed for A5 patients, corresponding to a 14% risk of liver decompensation. This result is applicable only to our administration conditions: glass spheres after a decay interval of 3.75 days. Different safety limit (40 Gy) are

  2. S values at voxels level for 188Re and 90Y calculated with the MCNP-4C code

    International Nuclear Information System (INIS)

    Coca Perez, Marco Antonio; Torres Aroche, Leonel Alberto; Cornejo, Nestor; Martin Hernandez, Guido

    2003-01-01

    The main objective of this work was estimate the voxels S values for 188 Re at cubical geometry using the MCNP-4C code for the simulation of radiation transport and energy deposition. Mean absorbed dose to target voxels per radioactive decay in a source voxels were estimated and reported for 188 Re and Y 90 . A comparison of voxels S values computed with the MCNP code the data reported in MIRD pamphlet 17 for 90 Y was performed in order to evaluate our results

  3. Preparation of chitosan/nano hydroxyapatite organic-inorganic hybrid microspheres for bone repair.

    Science.gov (United States)

    Chen, Jingdi; Pan, Panpan; Zhang, Yujue; Zhong, Shengnan; Zhang, Qiqing

    2015-10-01

    In this work, we encapsulated icariin (ICA) into chitosan (CS)/nano hydroxyapatite (nHAP) composite microspheres to form organic-inorganic hybrid microspheres for drug delivery carrier. The composition and morphology of composite microspheres were characterized by X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM) and differential scanning calorimetry- thermogravimetric analysis (DSC-TGA). Moreover, we further studied the performance of swelling properties, degradation properties and drug release behavior of the microspheres. ICA, the extract of traditional Chinese medicine-epimedium, was combined to study drug release properties of the microspheres. ICA loaded microspheres take on a sustained release behavior, which can be not only ascribed to electrostatic interaction between reactive negative hydroxyl (OH) of ICA and positive amine groups (NH₂) of CS, but also depended on the homogeneous dispersion of HAP nanoparticles inside CS organic matrix. In addition, the adhesion and morphology of osteoblasts were detected by inverted fluorescence microscopy. The biocompatibility of CS/nHAP/ICA microspheres was evaluated by the MTT cytotoxicity assay, Hoechst 33258 and PI fluorescence staining. These studies demonstrate that composite microspheres provide a suitable microenvironment for osteoblast attachment and proliferation. It can be speculated that the ICA loaded CS-based organic-inorganic hybrid microspheres might have potential applications in drug delivery systems. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Investigation of control conditions of uranium dioxide pellets sinterability through microspheres

    International Nuclear Information System (INIS)

    Assis, Gino de.

    1996-01-01

    Promotion or inhibition of ceramic powders sinterability, the decisive question in ceramic processing is approached in this dissertation. Each high density microsphere has been considered as a solid inclusion in a low density microspheres matrix, generating big pores. Such pores make it difficult for the pellets density due the fact that they are difficult to be eliminated. A master mixture, allowing the pellet densification in the projected range has been reached. Batches of microspheres have been observed sometimes with high apparent density and sometimes with low apparent density. This apparent density variation was attributed to changing the oxygen partial pressure during calcination under air atmosphere. It is evident that the control of the apparent density of the microspheres needs a further research in order to adjust the sinterability of the microspheres on the desired level.It was demonstrated that the produced microspheres do not have impurities levels that can promote its sinterability or avoid their use in nuclear area

  5. Recent advances in polymeric microspheres for parenteral drug delivery--part 1.

    Science.gov (United States)

    Mao, Shirui; Guo, Chunqiang; Shi, Yi; Li, Luk Chiu

    2012-09-01

    Polymeric microspheres have been established as a valuable parenteral drug delivery system for sustained release of therapeutic agents via subcutaneous or intramuscular injection. Biodegradable polymers which are either synthetic or from natural sources are reviewed with respect to recent advances in exploring their applications for microsphere fabrications. New information on the impact of formulation variables on the properties of microspheres formed by an emulsion method was also presented. The characterization of microspheres using advanced physical analytical techniques was also reviewed and the utilization of the information in assessing in vivo performance of the product was also highlighted. The broad clinical use of microspheres for delivery of therapeutic agents in particular biologics such as proteins has not been realized commercially. The limited availability of biodegradable polymers with a long history of regulatory approval and the challenges in gaining regulatory approval of a new polymer have hindered the development of microspheres for parenteral drug delivery.

  6. Formulation and characterization of ketoprofen embedded polycaprolactone microspheres using solvent evaporation method

    Directory of Open Access Journals (Sweden)

    Pankaj Wagh

    2015-07-01

    Full Text Available The purpose of this study was to prepare polymeric microspheres containing Ketoprofen (KFN by single emulsion [oil-in-water (o/w] solvent evaporation method. Polycaprolactone (PCL, biocompatible polymer, was used for the preparation of sustained released microspheres of KFN. A Plackett–Burman design was employed by using the Design-Expert® software (Version- 9.0.3.1, Stat-Ease Inc., Minneapolis, MN. Eleven factors out of six processing factors were investigated in order to enhance the encapsulation efficiency (EE of the microspheres. The resultant microspheres were characterized for their size, morphology, EE, and drug release. Imaging of particles was performed by field emission scanning electron microscopy. Interaction between the drug and polymers were investigated by Fourier transform infrared (FTIR spectroscopy, X-ray powder diffractometry (XRPD and Differential Scanning Calorimetry (DSC. Graphical and mathematical analyses of the design showed that concentration of factor PCL (B and varying speed (F, revolution per minute, rpm were significant negative effect on the EE and identified as the significant factor determining the EE of the microspheres. The microspheres showed high % EE (31.18 % to 96.81 %. The microspheres were found to be discrete, oval with porous surface. The FTIR analysis confirmed no interaction of KFN with the polymer. The XRPD revealed the dispersion of drug within microspheres formulation. Sustained drug release profile over 12 h was achieved by PCL polymer. In conclusion, polymeric microspheres containing KFN can be successfully prepared using the technique of experimental design, and these results helped in finding the optimum formulation variables for EE of microspheres.

  7. Formulation and Evaluation of Microspheres Based on Gelatin ...

    African Journals Online (AJOL)

    Formulation and Evaluation of Microspheres Based on Gelatin-Mucin Admixtures for the Rectal Delivery of Cefuroxime Sodium. K C Ofokansi, M U Adikwu. Abstract. Purpose: Swellable microspheres based on polymers or their admixtures are frequently employed as drug delivery systems to achieve a controlled release ...

  8. Polymer-coated albumin microspheres as carriers for intravascular tumour targeting of cisplatin.

    Science.gov (United States)

    Verrijk, R; Smolders, I J; McVie, J G; Begg, A C

    1991-01-01

    We used a poly-lactide-co-glycolide polymer (PLAGA 50:50) to formulate cisplatin (cDDP) into microspheres designed for intravascular administration. Two systems were developed. PLAGA-coated albumin microspheres and microspheres consisting of PLAGA only. PLAGA-coated microspheres displayed a mean diameter of 31.8 +/- 0.9 microns and a payload of 7.5% cDDP (w/w). Solid PLAGA microspheres exhibited a mean diameter of 19.4 +/- 0.6 microns and a payload of 20% cDDP. Release characteristics and in vitro effects on L1210 leukemia and B16 melanoma cell lines were investigated. Both types of microsphere overcame the initial rapid release of cDDP (burst effect), and PLAGA-coated albumin microspheres also showed a lag phase of approximately 30 min before cDDP release began. PLAGA-coated albumin microspheres released most of their payload through diffusion, and the coating eventually cracked after 7 days' incubation in saline supplemented with 0.1% Tween at 37 degrees C, enabling the release of any cDDP remaining. Effects of platinum, pre-released from PLAGA-coated albumin microspheres on the in vitro growth of L1210 cells were comparable with those of standard formulations (dissolved) of cDDP. Material released from non-drug-loaded PLAGA microspheres had no effect on L1210 cell growth, suggesting the absence of cytotoxic compounds in the matrix. The colony-forming ability of B16 cells was also equally inhibited by standard cDDP and pre-released drug. These studies show that formulation of cDDP in PLAGA-based microspheres prevents the rapid burst effect of cDDP seen in previous preparations and offers an improved system of administration for hepatic artery infusion or adjuvant therapy, enabling better clinical handling and the promise of a higher ratio of tumour tissue to normal tissue.

  9. Ulex europaeus 1 lectin targets microspheres to mouse Peyer's patch M-cells in vivo.

    Science.gov (United States)

    Foster, N; Clark, M A; Jepson, M A; Hirst, B H

    1998-03-01

    The interaction of latex microspheres with mouse Peyer's patch membranous M-cells was studied in a mouse gut loop model after the microspheres were coated with a variety of agents. Carboxylated microspheres (diameter 0.5 micron) were covalently coated with lectins Ulex europaeus 1, Concanavalin A, Euonymus europaeus and Bandeiraea simplicifolia 1 isolectin-B4, human immunoglobulin A or bovine serum albumin. Of the treatments examined, only Ulex europaeus (UEA1) resulted in significant selective binding of microspheres to M-cells. UEA1-coated microspheres bound to M-cells at a level 100-fold greater than BSA-coated microspheres, but binding to enterocytes was unaffected. Incubation of UEA1-coated microspheres with alpha-L-fucose reduced M-cell binding to a level comparable with BSA-coated microspheres. This indicated that targeting by UEA1 was via a carbohydrate receptor on the M-cell surface. Adherence of UEA1-coated microspheres to M-cells occurred within 10 min of inoculation into mouse gut loops and UEA1-coated microspheres were transported to 10 microns below the apical surface of M-cells within 60 min of inoculation. UEA1-coated microspheres also targeted mouse Peyer's patch M-cells after intragastric administration. These results demonstrated that altering the surface chemistry of carboxylated polystyrene microspheres increased M-cell targeting, suggesting a strategy to enhance delivery of vaccine antigens to the mucosal immune system.

  10. Investigation of defects on PAMS microspheres fabricated with microencapsulation method

    International Nuclear Information System (INIS)

    Chen Sufen; Li Bo; Liu Yiyang; Zhang Zhanwen; Qi Xiaobo

    2012-01-01

    Poly-(α-methylstyrene) (PAMS) microspheres were fabricated with W1/O/W2 double emulsion microencapsulation method, and the effects of polyvinylalcohol (PVA) and CaCl 2 weight concentrations and the O/W2 phase ratio on the percentages of defected PAMS microspheres were studied. The weight concentrations of PVA and CaCl 2 and the O/W2 phase ratio in the fabrication process of PAMS microspheres were optimized. The results show that, for the three parameters being 1.0%, 1.5%, and 0.01, respectively, the percentage of the defect-free PAMS microspheres without vacuoles in the shell wall can be up to 60%. (authors)

  11. Gold nanorod-mediated hyperthermia enhances the efficacy of HPMA copolymer-90Y conjugates in treatment of prostate tumors

    International Nuclear Information System (INIS)

    Buckway, Brandon; Frazier, Nick; Gormley, Adam J.; Ray, Abhijit; Ghandehari, Hamidreza

    2014-01-01

    Introduction: The treatment of prostate cancer using a radiotherapeutic 90 Y labeled N-(2-hydroxypropyl)methacrylamide (HPMA) copolymer can be enhanced with localized tumor hyperthermia. An 111 In labeled HPMA copolymer system for single photon emission computerized tomography (SPECT) was developed to observe the biodistribution changes associated with hyperthermia. Efficacy studies were conducted in prostate tumor bearing mice using the 90 Y HPMA copolymer with hyperthermia. Methods: HPMA copolymers containing 1, 4, 7, 10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) were synthesized by reversible addition-fragmentation transfer (RAFT) copolymerization and subsequently labeled with either 111 In for imaging or 90 Y for efficacy studies. Radiolabel stability was characterized in vitro with mouse serum. Imaging and efficacy studies were conducted in DU145 prostate tumor bearing mice. Imaging was performed using single photon emission computerized tomography (SPECT). Localized mild tumor hyperthermia was achieved by plasmonic photothermal therapy using gold nanorods. Results: HPMA copolymer-DOTA conjugates demonstrated efficient labeling and stability for both radionuclides. Imaging analysis showed a marked increase of radiolabeled copolymer within the hyperthermia treated prostate tumors, with no significant accumulation in non-targeted tissues. The greatest reduction in tumor growth was observed in the hyperthermia treated tumors with 90 Y HPMA copolymer conjugates. Histological analysis confirmed treatment efficacy and safety. Conclusion: HPMA copolymer-DOTA conjugates radiolabeled with both the imaging and treatment radioisotopes, when combined with hyperthermia can serve as an image guided approach for efficacious treatment of prostate tumors

  12. SCL-90 R: Distrés psicológico, género y conductas de riesgo / SCL-90 R: Psychological Distress, Gender and Risky Behaviors

    Directory of Open Access Journals (Sweden)

    Nancy Patricia Caballero Suárez

    2013-03-01

    Full Text Available Con base en una muestra probabilística de 466 estudiantes universitarios mexicanos, se explora la relación entre distrés psicológico y conductas de riesgo (consumo de sustancias, conductas sexuales, y ambas, en hombres y mujeres. Los resultados indican que el distrés psicológico presenta diferencias con mayor frecuencia en el caso de las mujeres que presentan consumo de drogas, tabaco y alcohol, o conductas que mezclan sexo y alcohol, y sexo y consumo de drogas, que en el caso de los hombres. Los hombres con actividad sexual ocasional presentan mayor distrés que quellos que no presentan esta conducta. Como punto de partida, se explora la estructura factorial del SCL-90-R, coincidiendo en los resultados con los obtenidos por investigadores de otras latitudes; al parecer, el análisis factorial no soporta la estructura propuesta por los autores del instrumento.

  13. Radioisotope diagnosis of pneumonia with the help of labelled microspheres of the blood serum albumin of man (experimental study)

    International Nuclear Information System (INIS)

    Khachirov, Dzh.G.; Petriev, V.M.

    1978-01-01

    The level of accumulation of albumin- 131 I microspheres in the lungs of intact animals reaches 90 per cent of the activity of the introduced preparation. In experimental pneumonia the inclusion of the preparation comprises 81.1+-6.23 per cent. The elimination of the labelled preparation from the lungs in experimental pneumonia occurs two times as slow than that in the control. The labelled microspheres of albumin make it possible to visualize the focus of inflammation, its spreading, conduct observations in dynamics. The peculiarities of accumulation and elimination from the lungs of the mentioned preparation make it possible with its help to differentiate pathological conditions of the lungs: inflammatory process, malignant neoformations and experimental embolism of the pulmonary artery

  14. Involvement of Rho kinase in the pathogenesis of acute pulmonary embolism-induced polystyrene microspheres in rats.

    Science.gov (United States)

    Toba, M; Nagaoka, T; Morio, Y; Sato, K; Uchida, K; Homma, N; Takahashi, K

    2010-03-01

    Acute pulmonary embolism (PE) is a life-threatening disease, and several vasoconstrictors, including endothelin-1 (ET-1), play a key role in vasoconstriction and hypoxemia during the development of PE. Rho kinase is activated by various vasoconstrictors resulting in vascular contraction and remodeling. Recent evidence has revealed an important role of Rho kinase in the pathogenesis of systemic and pulmonary vascular diseases. However, contribution of Rho kinase in PE remains unclear. We thus investigated the role of Rho kinase in the PE rat model induced by intrajugular administration of polystyrene microspheres (mean diameter, 26 microm). At 6 h following the administration of microspheres (1.5 ml/kg), right ventricular systolic pressure (RVSP) was higher in the PE than in the control rats (15.8 +/- 1.6 vs. 32.9 +/- 7.5 mmHg). Arterial oxygen tension was lower (92.3 +/- 12.5 vs. 66.0 +/- 17.7 Torr), and alveolar-arterial difference in oxygen partial pressure was higher (3.9 +/- 3.8 vs. 36.5 +/- 26.9 Torr) in the PE rats. Western blotting analysis revealed upregulation and downregulation in expression of vascular cell adhesion molecule-1 and endothelial nitric oxide synthase in lungs from the PE rats, respectively, and radioimmunoassay demonstrated an increase in plasma ET-1 levels. Lung Rho kinase alpha expression was greater in the PE rats. At 5 h following administration of microspheres (0.75 ml/kg), intravenous Rho kinase inhibitors HA1077 and Y27632 (3 mg/kg each) attenuated elevation of RVSP (22.0 +/- 3.7, 17.1 +/- 3.2, 14.3 +/- 2.6 mmHg, PE, PE+HA1077, PE+Y27632) and the severity of hypoxemia (66.3 +/- 16.2, 94.9 +/- 23.0, 89.1 +/- 8.5 Torr, PE, PE+HA1077, PE+Y27632) in the PE rats. These results suggest that pulmonary endothelial dysfunction and activation of Rho kinase may contribute to the potentiation of vasoconstriction and hypoxemia in the PE rats.

  15. Yttrium-90 microspheres for the treatment of hepatocellular carcinoma: A review

    International Nuclear Information System (INIS)

    Salem, Riad; Hunter, Russell D.

    2006-01-01

    To present a critical review of yttrium-90 (TheraSphere) for the treatment of hepatocellular carcinoma (HCC). Medical literature databases (Medline, Cochrane Library, and CANCERLIT) were searched for available literature concerning the treatment of HCC with TheraSphere. These publications were reviewed for scientific and clinical validity. Studies pertaining to the use of yttrium-90 for HCC date back to the 1960s. The results from the early animal safety studies established a radiation exposure range of 50-100 Gy to be used in human studies. Phase I dose escalation studies followed, which were instrumental in delineating radiation dosimetry and safety parameters in humans. These early studies emphasized the importance of differential arteriolar density between hypervascular HCC and surrounding liver parenchyma. Current trends in research have focused on advancing techniques to safely implement this technology as an alternative to traditional methods of treating unresectable HCC, such as external beam radiotherapy, conformal beam radiotherapy, ethanol ablation, trans-arterial chemoembolization, and radiofrequency ablation. Yttrium-90 (TheraSphere) is an outpatient treatment option for HCC. Current and future research should focus on implementing multicenter phase II and III trials comparing TheraSphere with other therapies for HCC

  16. Yttrium-90 microspheres for the treatment of hepatocellular carcinoma: a review.

    Science.gov (United States)

    Salem, Riad; Hunter, Russell D

    2006-01-01

    To present a critical review of yttrium-90 (TheraSphere) for the treatment of hepatocellular carcinoma (HCC). Medical literature databases (Medline, Cochrane Library, and CANCERLIT) were searched for available literature concerning the treatment of HCC with TheraSphere. These publications were reviewed for scientific and clinical validity. Studies pertaining to the use of yttrium-90 for HCC date back to the 1960s. The results from the early animal safety studies established a radiation exposure range of 50-100 Gy to be used in human studies. Phase I dose escalation studies followed, which were instrumental in delineating radiation dosimetry and safety parameters in humans. These early studies emphasized the importance of differential arteriolar density between hypervascular HCC and surrounding liver parenchyma. Current trends in research have focused on advancing techniques to safely implement this technology as an alternative to traditional methods of treating unresectable HCC, such as external beam radiotherapy, conformal beam radiotherapy, ethanol ablation, trans-arterial chemoembolization, and radiofrequency ablation. Yttrium-90 (TheraSphere) is an outpatient treatment option for HCC. Current and future research should focus on implementing multicenter phase II and III trials comparing TheraSphere with other therapies for HCC.

  17. Uptake kinetics of the somatostatin receptor ligand [86Y]DOTA-dPhe1-Tyr3-octreotide ([86Y]SMT487) using positron emission tomography in non-human primates and calculation of radiation doses of the 90Y-labelled analogue

    International Nuclear Information System (INIS)

    Roesch, F.; Brockmann, J.; Koehle, M.

    1999-01-01

    [ 90 Y]DOTA-dPhe 1 -Tyr 3 -octreotide ([ 90 Y]-SMT487) has been suggested as a promising radiotherapeutic agent for somatostatin receptor-expressing tumours. In order to quantify the in vivo parameters of this compound and the radiation doses delivered to healthy organs, the analogue [ 86 Y]DOTA-dPhe 1 -Tyr 3 -octreotide was synthesised and its uptake measured in baboons using positron emission tomography (PET). [ 86 Y]DOTA-dPhe 1 -Tyr 3 -octreotide was administered at two different peptide concentrations, namely 2 and 100 μg peptide per m 2 body surface. The latter concentration corresponded to a radiotherapeutic dose. In a third protocol [ 86 Y]DOTA-dPhe 1 -Tyr 3 -octreotide was injected in conjunction with a simultaneous infusion of an amino acid solution that was high in l-lysine in order to lower the renal uptake of radioyttrium. Quantitative whole-body PET scans were recorded to measure the uptake kinetics for kidneys, liver, lung and bone. The individual absolute uptake kinetics were used to calculate the radiation doses for [ 90 Y]DOTA-dPhe 1 -Tyr 3 -octreotide according to the MIRD recommendations extrapolated to a 70-kg human. The highest radiation dose was received by the kidneys, with 2.1-3.3 mGy per MBq [ 90 Y]DOTA-dPhe 1 -Tyr 3 -octreotide injected. For the 100 μg/m 2 SMT487 protocol with amino acid co-infusion this dose was about 20%-40% lower than for the other two treatment protocols. The liver and the red bone marrow received doses ranging from 0.32 to 0.53 mGy and 0.03 to 0.07 mGy per MBq [ 90 Y]DOTA-dPhe 1 -Tyr 3 -octreotide, respectively. The average effective dose equivalent amounted to 0.23-0.32 mSv/MBq. The comparatively low estimated radiation doses to normal organs support the initiation of clinical phase I trials with [ 90 Y]DOTA-dPhe 1 -Tyr 3 -octreotide in patients with somatostatin receptor-expressing tumours. (orig.)

  18. Microfluidic Fabrication of Morphology-Controlled Polymeric Microspheres of Blends of Poly(4-butyltriphenylamine and Poly(methyl methacrylate

    Directory of Open Access Journals (Sweden)

    Saki Yoshida

    2018-04-01

    Full Text Available Multicomponent polymer particles with specific morphology are promising materials exhibiting novel functionality which cannot be obtained with single-component polymer particles. Particularly, the preparation of such kinds of polymer particles involving electrically or optically active conjugated polymers with uniform size is a challenging subject due to their intense demands. Here, microspheres of binary polymer blend consisting of poly(4-butyltriphenylamine (PBTPA/poly(methyl methacrylate (PMMA (1:1 in weight were produced via a microfluidic emulsification with a Y-shaped microreactor, and a subsequent solvent evaporation method. The flow rate of the dispersed phase (polymer solution was fixed to 7 µL/min, and 140 or 700 µL/min of the flow rate of the continuous phase (aqueous 0.6 wt % of poly(vinyl alcohol (PVA solution was utilized to produce the dispersion with different diameter. The concentration of dispersed phase was adjusted to 0.1 or 1.0 w/v%. Core-shell, Janus and dumbbell type microspheres were obtained dependent on the flow rate of continuous phase. Incomplete core-shell type microspheres were produced for the blend involving low molecular weight PMMA. Complex Janus and core-shell type microspheres were fabricated by the addition of sodium dodecyl sulfate (SDS to continuous phase. It is found that final morphologies are strongly dependent on the initial conditions of dispersion including the particle size suggesting that the morphologies are governed by the kinetical factors together with the conventionally accepted thermodynamic ones.

  19. Polydimethylsiloxane microspheres with poly(methyl methacrylate) coating: Modelling, preparation, and characterization

    DEFF Research Database (Denmark)

    Ma, Baoguang; Hansen, Jens Henrik; Hvilsted, Søren

    2015-01-01

    functional PDMS microspheres were coated with poly(methyl methacrylate) (PMMA) by spin coating with different concentrations of PMMA solutions. The quality of the resulting PMMA shell is investigated using rheological measurements at 50 8C with a timesweep procedure. The results strongly suggest that PMMA-coated...... PDMS microspheres react around 20 times slower than the uncoated ones, and that the PMMA shell significantly hinders the reaction between the PDMS microsphere and cross-linker. Thus the thin PMMA shells are very efficient in protecting the reactive PDMS microspheres, since the PMMA shell forms...

  20. FEMIC (Fibromes Embolises aux MICrospheres calibrees): Uterine Fibroid Embolization using Tris-acryl Microspheres. A French Multicenter Study

    International Nuclear Information System (INIS)

    Joffre, Francis; Tubiana, Jean-Michel; Pelage, Jean-Pierre

    2004-01-01

    Purpose: A French multicenter registry was set up to confirm the safety and efficacy of large calibrated tris-acryl gelatin microspheres for embolization of symptomatic fibroids. Methods: Technical recommendations included embolization using large microspheres (>500 μm) with no secondary embolization agent. Postprocedural pain, clinical improvement and adverse events were prospectively evaluated during a follow-up period of at least 6 months.Results: Eighty-five women complaining of fibroid-related symptoms entered the study. In seven women, a secondary embolization agent was used in addition to microspheres. Complete resolution of menorrhagia was achieved in 84% of women at 24 months and significant uterine and fibroid volume reductions were noted after 6 months (37% and 73%, respectively). Three women experienced definitive amenorrhea (4%) and two women required hysteroscopic resection of a fibroid. Eight women were treated by hysterectomy because of treatment failure. In seven of these women, treatment failure was explained by an additional cause of symptoms including diffuse adenomyosis, endometrial hyperplasia or ovarian artery supply to the fibroids.Conclusion: Limited uterine artery embolization using large microspheres has good clinical success rate with low postprocedural pain and complications. Women can expect excellent midterm results with a high level of symptom control and significant fibroid volume reduction. Confidence in the end-point recommended here may require the experience of several cases