WorldWideScience

Sample records for preoperative intra-aortic balloon

  1. Predictors of cardiogenic shock in cardiac surgery patients receiving intra-aortic balloon pumps.

    Science.gov (United States)

    Iyengar, Amit; Kwon, Oh Jin; Bailey, Katherine L; Ashfaq, Adeel; Abdelkarim, Ayman; Shemin, Richard J; Benharash, Peyman

    2018-02-01

    Cardiogenic shock after cardiac surgery leads to severely increased mortality. Intra-aortic balloon pumps may be used during the preoperative period to increase coronary perfusion. The purpose of this study was to characterize predictors of postoperative cardiogenic shock in cardiac surgery patients with and without intra-aortic balloon pumps support. We performed a retrospective analysis of our institutional database of the Society of Thoracic Surgeons for patients operated between January 2008 to July 2015. Multivariable logistic regression was used to model postoperative cardiogenic shock in both the intra-aortic balloon pumps and matched control cohorts. Overall, 4,741 cardiac surgery patients were identified during the study period, of whom 192 (4%) received a preoperative intra-aortic balloon pump. Intra-aortic balloon pumps patients had a greater prevalence of diabetes, previous cardiac surgery, congestive heart failure, and an urgent/emergent status (P pumps patients also had greater 30-day mortality and more postoperative cardiogenic shock (9% vs 3%, P pumps cohort, only sex, previous percutaneous coronary intervention and preoperative arrhythmia remained significant on multivariable analysis (all P pumps and those who do not. Further analysis of the effects of prophylactic intra-aortic balloon pumps support is warranted. (Surgery 2017;160:XXX-XXX.). Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Preoperative optimization of multi-organ failure following acute myocardial infarction and ischemic mitral regurgitation by placement of a transthoracic intra-aortic balloon pump.

    Science.gov (United States)

    Umakanthan, Ramanan; Dubose, Robert; Byrne, John G; Ahmad, Rashid M

    2010-10-01

    The management of acute myocardial infarction with resultant acute ischemic mitral regurgitation and acute multi-organ failure can prove to be a very challenging scenario. The presence of concomitant vascular disease can only serve to further compromise the complexity of the situation. We demonstrate a new indication for the transthoracic intra-aortic balloon pump as a preoperative means of unloading the heart and improving clinical outcome in such high-risk patients with severe vascular disease. We present the case of a 75-year-old man with a history of severe vascular disease who was transferred emergently to Vanderbilt University Medical Center with an acute inferolateral wall myocardial infarction resulting in severe acute ischemic mitral regurgitation and acute multi-organ failure. He presented with shock liver (serum glutamic-oxaloacetic transaminase [SGOT] of 958), renal failure (creatinine of 3.0), and respiratory failure with a pH of 7.18. Emergent cardiac catheterization revealed 100% occlusion of the left circumflex artery as well as severe ileofemoral disease. The advanced nature of his ileofemoral disease was such that the arterial access catheter occluded the right femoral artery. The duration of time that the catheter was in the artery led to transient limb ischemia with an elevation of his creatine phosphokinase (CPK) to 10,809. Balloon angioplasty followed by stent placement was successfully performed, which restored flow to the coronary vessel. Given the grave nature of the patient's condition, we were very concerned that immediate operative intervention for his condition would entail prohibitively high risk. In fact, the Society of Thoracic Surgeons predicted risk adjusted mortality was calculated to be 56%. In order to minimize patient mortality and morbidity, it was critical to help restore perfusion and organ recovery. Therefore, we decided that the chances for this patient's survival would improve if his condition could be optimized by

  3. Benefits of ambulatory axillary intra-aortic balloon pump for circulatory support as bridge to heart transplant.

    Science.gov (United States)

    Umakanthan, Ramanan; Hoff, Steven J; Solenkova, Natalia; Wigger, Mark A; Keebler, Mary E; Lenneman, Andrew; Leacche, Marzia; Disalvo, Thomas G; Ooi, Henry; Naftilan, Allen J; Byrne, John G; Ahmad, Rashid M

    2012-05-01

    Axillary intra-aortic balloon pump therapy has been described as a bridge to transplant. Advantages over femoral intra-aortic balloon pump therapy include reduced incidence of infection and enhanced patient mobility. We identified the patients who would benefit most from this therapy while awaiting heart transplantation. We conducted a single-center, retrospective observational study to evaluate outcomes from axillary intra-aortic balloon pump therapy. These included hemodynamic parameters, duration of support, and success in bridging to transplant. We selected patients on the basis of history of sternotomy, elevated panel-reactive antibody, and small body habitus. Patients were made to ambulate aggressively beginning on postoperative day 1. Between September 2007 and September 2010, 18 patients underwent axillary intra-aortic balloon pump therapy. All patients had the devices placed through the left axillary artery with a Hemashield side graft (Boston Scientific, Natick, Mass). Before axillary placement, patients underwent femoral placement to demonstrate hemodynamic benefit. Duration of support ranged from 5 to 63 days (median = 19 days). There was marked improvement in ambulatory potential and hemodynamic parameters, with minimal blood transfusion requirements. There were no device-related infections. Some 72% of the patients (13/18) were successfully bridged to transplantation. Axillary intra-aortic balloon pump therapy provides excellent support for selected patients as a bridge to transplant. The majority of the patients were successfully bridged to transplant and discharged. Although this therapy has been described in previous studies, this is the largest series to incorporate a regimen of aggressive ambulation with daily measurements of distances walked. Copyright © 2012. Published by Mosby, Inc.

  4. Intra Aortic Balloon Pump (IABP: Past, Present and Future

    Directory of Open Access Journals (Sweden)

    Jatin D Dedhia

    2008-01-01

    Full Text Available Intra Aortic Balloon Pump (IABP is the most commonly used mechanical circulatory assist device in cardiac patients. IABP can improve ventricular function by decreasing the preload and increasing systolic output with signifi-cant improvement in myocardial oxygen supply/demand ratio. Pre-operative IABP therapy in ′high-risk′ coronary patients has been shown to reduce hospital mortality and shorten ICU stay significantly, compared with controls. The introduction of sheathless insertion kits has reduced the incidence of vascular complication rates. Pro-Active Counter Pulsation is a new IABP system which automatically detects the irregular pattern and result is an improvement in the haemodynamic effect of IABP during periods of arrhythmia. Today, continued improvements in IABP technology permit safer use and earlier intervention to provide haemodynamic support. These developments have made the IABP a mainstay in the management of ischemic and dysfunctional myocardium. This review article aims to provide basic concept of IABP to hospital doctors especially anaesthetists, intensivists cardiologists and cardiac surgeons. It discusses the common indications, contraindications, the physiologic aspects of IABP, the equipment needed to facilitate IABP, the use of the IABP in special situations and complications of its use.

  5. Effect of intra-aortic balloon pump on coronary blood flow during different balloon cycles support: A computer study.

    Science.gov (United States)

    Aye, Thin Pa Pa; Htet, Zwe Lin; Singhavilai, Thamvarit; Naiyanetr, Phornphop

    2015-01-01

    Intra-aortic balloon pump (IABP) has been used in clinical treatment as a mechanical circulatory support device for patients with heart failure. A computer model is used to study the effect on coronary blood flow (CBF) with different balloon cycles under both normal and pathological conditions. The model of cardiovascular and IABP is developed by using MATLAB SIMULINK. The effect on coronary blood flow has been studied under both normal and pathological conditions using different balloon cycles (balloon off; 1:4; 1:2; 1:1). A pathological heart is implemented by reducing the left ventricular contractility. The result of this study shows that the rate of balloon cycles is related to the level of coronary blood flow.

  6. The management of impending myocardial infarction using coronary artery by-pass grafting and an intra-aortic balloon pump.

    Science.gov (United States)

    Harris, P L; Woollard, K; Bartoli, A; Makey, A R

    1980-01-01

    Of 33 patients with impending myocardial infarction 25 were treated using a combination of coronary artery by-pass grafting and intra-aortic balloon pumping. Eight patients were treated with coronary artery by-pass grafting alone. Twenty-two of the 25 patients who were treated with the combined technique made a full recovery. Three patients sustained definite myocardial infarctions and one of these died. Five of the 8 patients treated by grafting alone suffered infarction and of these 3 died. The value of intra-aortic balloon pumping in combination with coronary artery by-pass grafting in the management of impending myocardial infarction is discussed.

  7. Measurements of Intra-Aortic Balloon Wall Movement During Inflation and Deflation: Effects of Angulation.

    Science.gov (United States)

    Bruti, Gianpaolo; Kolyva, Christina; Pepper, John R; Khir, Ashraf W

    2015-08-01

    The intra-aortic balloon pump (IABP) is a ventricular assist device that is used with a broad range of pre-, intra-, and postoperative patients undergoing cardiac surgery. Although the clinical efficacy of the IABP is well documented, the question of reduced efficacy when patients are nursed in the semi-recumbent position remains outstanding. The aim of the present work is therefore to investigate the underlying mechanics responsible for the loss of IABP performance when operated at an angle to the horizontal. Simultaneous recordings of balloon wall movement, providing an estimate of its diameter (D), and fluid pressure were taken at three sites along the intra-aortic balloon (IAB) at 0 and 45°. Flow rate, used for the calculation of displaced volume, was also recorded distal to the tip of the balloon. An in vitro experimental setup was used, featuring physiological impedances on either side of the IAB ends. IAB inflation at an angle of 45° showed that D increases at the tip of the IAB first, presenting a resistance to the flow displaced away from the tip of the balloon. The duration of inflation decreased by 15.5%, the inflation pressure pulse decreased by 9.6%, and volume decreased by 2.5%. Similarly, changing the position of the balloon from 0 to 45°, the balloon deflation became slower by 35%, deflation pressure pulse decreased by 14.7%, and volume suctioned was decreased by 15.2%. IAB wall movement showed that operating at 45° results in slower deflation compared with 0°. Slow wall movement, and changes in inflation and deflation onsets, result in a decreased volume displacement and pressure pulse generation. Operating the balloon at an angle to the horizontal, which is the preferred nursing position in intensive care units, results in reduced IAB inflation and deflation performance, possibly compromising its clinical benefits. Copyright © 2015 The Authors. Artificial Organs published by Wiley Periodicals, Inc. on behalf of International Center for

  8. 78 FR 36702 - Cardiovascular Devices; Reclassification of Intra-Aortic Balloon and Control Systems (IABP) for...

    Science.gov (United States)

    2013-06-19

    .... FDA-2013-N-0581] Cardiovascular Devices; Reclassification of Intra-Aortic Balloon and Control Systems... Device In the preamble to the proposed rule (44 FR 13369; March 9, 1979), the Cardiovascular Device... Bypass Grafting: A Propensity Score Analysis,'' Interactive Cardiovascular and Thoracic Surgery, vol. 9...

  9. 78 FR 79300 - Cardiovascular Devices; Reclassification of Intra-Aortic Balloon and Control Systems for Acute...

    Science.gov (United States)

    2013-12-30

    .... FDA-2013-N-0581] Cardiovascular Devices; Reclassification of Intra-Aortic Balloon and Control Systems... of these devices into class II. List of Subjects in 21 CFR Part 870 Medical devices, Cardiovascular... Commissioner of Food and Drugs, 21 CFR part 870 is amended as follows: PART 870--CARDIOVASCULAR DEVICES 0 1...

  10. Usefulness of intra-aortic balloon pump counterpulsation in patients with cardiogenic shock from acute myocardial infarction

    NARCIS (Netherlands)

    Cheng, Jin M.; Valk, Suzanne D. A.; den Uil, Corstiaan A.; van der Ent, Martin; Lagrand, Wim K.; van de Sande, Meike; van Domburg, Ron T.; Simoons, Maarten L.

    2009-01-01

    Although intra-aortic balloon pump (IABP) counterpulsation is increasingly being used for the treatment of patients with cardiogenic shock from acute myocardial infarction, data on the long-term outcomes are lacking. The aim of the present study was to evaluate the 30-day and long-term mortality and

  11. In vitro comparison of support capabilities of intra-aortic balloon pump and Impella 2.5 left percutaneous

    NARCIS (Netherlands)

    Schampaert, Stéphanie; van't Veer, Marcel; van de Vosse, Frans N.; Pijls, Nico H. J.; de Mol, Bas A.; Rutten, Marcel C. M.

    2011-01-01

    The Impella 2.5 left percutaneous (LP), a relatively new transvalvular assist device, challenges the position of the intra-aortic balloon pump (IABP), which has a long record in supporting patients after myocardial infarction and cardiac surgery. However, while more costly and more demanding in

  12. Virtual 5-French intra-aortic pumping using a Glidesheath Slender and 6-French intra-aortic balloon catheter

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Akihiko, E-mail: a-takahashi@wine.ocn.ne.jp; Taniguchi, Norimasa; Mizuguchi, Yukio; Yamada, Takeshi; Nakajima, Shunsuke; Hashimoto, Sho; Hata, Tetsuya

    2015-07-15

    Objectives: The aim of this study was to evaluate the feasibility and safety of the 6-Fr Glidesheath Slender, which has equivalent outer size to the conventional 5-Fr sheath, for use with the 6-Fr intra-aortic balloon pump (IABP) catheter. Methods: Between May 2014 and March 2015, 24 patients with acute coronary syndrome underwent percutaneous coronary intervention using a 6-Fr IABP catheter through a 6-Fr Glidesheath Slender for support. The adverse events, including access site complications, kinking of the sheath during the procedure, and any evidence of balloon pump failure, were retrospectively investigated. Results: Insertion of the IABP catheter through either the femoral or brachial artery was successful in all patients. The mean support time was 32.4 ± 22.0 h. No major hemorrhagic event or severe limb ischemia was observed. Kinking of the shaft occurred during insertion in one patient; however, the subsequent balloon pumping was well maintained and did not require exchange of the sheath or IABP catheter. No kind of IABP failure was observed. Conclusion: Although this sheath was originally designed to allow radial access, our results suggest that the use of the Glidesheath Slender is feasible for insertion of the 6-Fr IABP catheter through the brachial and femoral arteries, and may reduce vascular complications in patients who undergo percutaneous coronary intervention.

  13. Six-Month Outcomes After High-Risk Coronary Artery Bypass Graft Surgery and Preoperative Intra-aortic Balloon Counterpulsation Use: An Inception Cohort Study.

    Science.gov (United States)

    Litton, Edward; Bass, Frances; Delaney, Anthony; Hillis, Graham; Marasco, Silvana; McGuinness, Shay; Myles, Paul S; Reid, Christopher M; Smith, Julian A

    2018-01-05

    To inform the design of a pivotal randomized controlled trial of prophylactic intra-aortic balloon counterpulsation (IABC) in patients undergoing coronary artery bypass graft (CABG) at high risk of postoperative low cardiac output syndrome (LCOS). Inception cohort study. A total of 13 established cardiac centers in Australia, Canada, New Zealand, and the United Kingdom. Adult patients were eligible for inclusion if they were listed for CABG surgery and had 2 or more LCOS risk factors (low ejection fraction, severe left main coronary artery disease, redo sternotomy, unstable angina). Outcomes of interest were a composite outcome of in-hospital mortality, postoperative acute myocardial infarction (AMI), acute kidney injury (AKI), or stroke as well as 6-month vital status and quality of life using the EuroQol 5-dimensional questionnaire (EQ5D). The study included 136 participants over a 29-month period. Overall, in-hospital and 6-month mortality occurred in 7 (5%) and 11 (8%) participants, respectively. The composite outcome occurred in 60 (44%). The mean increase in EQ5D summary index at 6 months was 0.10 (standard deviation 0.24, p = 0.01). Perioperative AMI, AKI, or stroke significantly decreased the odds of a clinically meaningful improvement in quality of life (odds ratio 0.32; 95% confidence interval 0.13-0.79; p = 0.014). Preoperative IABC was used in 39 participants and did not predict postoperative outcomes. The study identified a group of patients at risk of LCOS in whom CABG surgery was associated with a substantial burden of perioperative morbidity. Preoperative IABC use was variable, supporting the need for further research. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Stimulus-response time to alarms of the intra-aortic balloon pump: safe care practices

    Directory of Open Access Journals (Sweden)

    Andrezza Serpa Franco

    Full Text Available ABSTRACT Objective: To characterize the sound alarms of the Intra-Aortic Balloon Pump (IABP during aortic counterpulsation therapy; to measure the stimulus-response time of the team to these; and to discuss the implications of increasing this time for patient safety from the alarm fatigue perspective. Method: This is an observational and descriptive study with quantitative and qualitative approach, case study type, carried out in a Cardiac Surgical Intensive Care Unit. Results: The most audible IABP alarm was the one of high priority increased-reduced diastolic blood pressure. The stimulus-response time was 33.9 seconds on average. Conclusion: Managing the alarms of these equipment is essential to minimize the occurrence of the alarm fatigue phenomenon and to offer a safer assistance to patients who rely on this technology.

  15. Intra-aortic balloon shape change: effects on volume displacement during inflation and deflation.

    Science.gov (United States)

    Khir, Ashraf William; Bruti, Gianpaolo

    2013-07-01

    It has been observed that operating the intra-aortic balloon at an angle to the horizontal resulted in a reduction of the volume displaced toward the coronary arteries and compromised afterload reduction. Therefore, the aim of this work is to examine whether changing the current balloon shape, which has not been altered for 40 years, could compensate for the negative hemodynamic effects due to angulation. We tested two tapered balloons, increasing diameter (TID) and decreasing diameter (TDD), and compared the results with those obtained from a standard cylindrical balloon. The balloons were tested in vitro at 60 beats/min and a static pressure of 90 mm Hg. The balloons were operated at four angles (0°, 20°, 30°, 45°), and the pressure at three locations along the balloon (base, middle, and tip) was also measured. Flow rate upstream of the tip of the balloon was also measured to indicate the flow displaced toward the coronary circulation. The relative volume displaced toward (VUTVi) and suctioned away from (VUTVd) the simulated ascending aorta, during inflation and deflation, respectively, is reduced when a standard cylindrical balloon is operated at an angle to the horizontal. The TDD provided the greatest VUTVi and also produced the largest pulse pressure during deflation. Although the TID provided less VUTVi and VUTVd at smaller angles, it was not markedly affected by the change of angle. According to these results, different balloon shapes analyzed, with comparable volume to that of a cylindrical balloon, produced greater inflation and deflation benefits, at the horizontal and at a range of angles to the horizontal. Further investigations are required to optimize the shape of the tapered balloons to fit into the available physiological space. © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

  16. In reply to: "Intra-aortic balloon pump protects against hydrostatic pulmonary oedema during peripheral venoarterial-extracorporeal membrane oxygenation".

    Science.gov (United States)

    Privratsky, Jamie R; Diaz, Sebastian; Nicoara, Alina; Daneshmand, Mani A

    2018-05-01

    Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is an increasingly utilized life-saving measure. However, left-ventricular distention from inadequate left-ventricular off-loading can lead to unwanted pulmonary and cardiac complications. We are writing to indicate our agreement with a recent article by Brechot et al. published in the June 2017 issue where the authors demonstrated that intra-aortic balloon pump provides mechanical support to off-load the left ventricle during VA-ECMO, which prevents pulmonary edema.

  17. Australasian trends in intra-aortic balloon counterpulsation weaning: results of a postal survey.

    Science.gov (United States)

    Lewis, Peter A; Mullany, Daniel V; Courtney, Mary; Coyer, Fiona

    2006-12-01

    To generate baseline data describing Australasian intra-aortic balloon counterpulsation (IABP) weaning practice. A five-part questionnaire was mailed in April 2005 to all 192 intensive care units in Australia and New Zealand. 116 ICUs responded (response rate, 60%), and 54 reported using IABP. Most of the 54 were in hospitals which were public government-funded (65%), had between 100 and 500 beds (69%), and treated a minimum of 11 patients annually with IABP (60%). The most common method of withdrawing IABP support was ratio reduction alone (61%). ICUs most likely to undertake ratio weaning were higherend users of IABP (> 20 cases per annum) (P = 0.04). Other weaning practices involved a combination of ratio followed by volume reduction (17%), volume then ratio (11%), and volume only (4%). Approaching statistical significance, ratio reduction weaning less frequently required IABP reinsertion or inotropic increase after balloon removal (P = 0.07). ICUs with documented weaning policies were less likely to require IABP reinsertion or inotropic increase after balloon removal (P = 0.06). Criteria considered important before IABP weaning or removal were: blood pressure (92%); heart rate (76%); pulmonary artery wedge pressure (59%); noradrenaline dose (78%); adrenaline dose (57%); and dobutamine dose (57%). Ninety per cent of ICUs reported increasing inotropes after balloon removal only rarely (1:50 patients) or occasionally (1:10 patients), while 87% of ICUs reported never needing to reinsert the balloon or only rarely. The Australasian approach to IABP weaning is eclectic. While ratio reduction weaning appears the most successful manner of support withdrawal, it may be a consequence of a volume-outcome relationship, with high- end users achieving better results through IABP familiarity.

  18. Cardiopulmonary bypass and intra-aortic balloon pump use is associated with higher short and long term mortality after transcatheter aortic valve replacement: a PARTNER trial substudy.

    Science.gov (United States)

    Shreenivas, Satya S; Lilly, Scott M; Szeto, Wilson Y; Desai, Nimesh; Anwaruddin, Saif; Bavaria, Joseph E; Hudock, Kristin M; Thourani, Vinod H; Makkar, Raj; Pichard, Augusto; Webb, John; Dewey, Todd; Kapadia, Samir; Suri, Rakesh M; Xu, Ke; Leon, Martin B; Herrmann, Howard C

    2015-08-01

    Transcatheter aortic valve replacement (TAVR) with the balloon-expandable Sapien transcatheter heart valve improves survival compared to standard therapy in patients with severe aortic stenosis (AS) and is noninferior to surgical aortic valve replacement (AVR) in patients at high operative risk. Nonetheless, a significant proportion of patients may require pre-emptive or emergent support with cardiopulmonary bypass (CPB) and/or intra-aortic balloon pump (IABP) during TAVR due to pre-existing comorbid conditions or as a result of procedural complications. We hypothesized that patients who required CPB or IABP would have increased periprocedural complications and reduced long-term survival. In addition, we sought to determine whether preprocedural variables could predict the need for CPB and IABP. The study population included 2,525 patients in the PARTNER Trial (Cohort A and B) and the continuing access registry (CAR). Patients that received CPB or IABP were compared to patients that did not receive either, and then further divided into those that received support pre-TAVR and those that were placed on support emergently. One-hundred sixty-three patients (6.5%) were placed on CPB and/or IABP. The use of CPB or IABP was associated with higher 1 year mortality (49.1% vs. 21.6%, P non-CPB/IABP cases (53.3% and 40.3% vs. 21.6%, P < 0.001). These findings indicate that CPB and IABP use in TAVR portends a poor prognosis and its utilization, particularly in the setting of pre-emptive use, needs reconsideration. © 2015 Wiley Periodicals, Inc.

  19. Fiber-optic intra-aortic balloon therapy and its role within cardiac surgery.

    Science.gov (United States)

    Yarham, G; Clements, A; Morris, C; Cumberland, T; Bryan, M; Oliver, M; Burrows, H; Mulholland, J

    2013-03-01

    The patient population has changed and the cardiothoracic team are now operating on patients with more co-morbidity. One of the significant aspects of this increased co-morbidity, which affects both short- and long-term outcomes, is compromised left ventricular function. Intra-aortic balloon pump (IABP) technology offers these patients and the cardiac team an easily accessible, cost-effective, mechanical assist device. Arterial pressure monitoring for IABP therapy: Fluid-filled transducers used to measure the aortic waveform can be unreliable and inconsistent. Fiber-optic manometers located in the very tip of the IAB catheters provide accurate and fast, high quality measurements. This, in turn, presents the opportunity for the hardware and algorithm to measure key markers on the arterial waveform and optimise left ventricular support. It also provides the potential for automatic in vivo calibration, further increasing the accuracy and quality of the IAB support. The effect of fiber-optic IABP therapy on clinical management: A dual centre prospective audit comparing fluid-filled versus fiber-optic arterial pressure monitoring showed a 96% reduction in IAB-related perfusion on-site call-outs (17 vs. 1, respectively) and a 94% reduction in sub-optimal timing (55/98 vs. 2/94, respectively). The improved timing algorithms utilise the pressure information received 50 msecs faster than with fluid-filled transducers, measuring key markers on the pressure waveform and adjusting inflation and deflation accurately on a beat per beat basis. Fiber-optic IAB technology and, specifically, these improved algorithms provide better beat per beat mechanical support. Given our evolving patient population, this technology will not only play an increased role, but will have a significant impact on cardiac surgery.

  20. Aortic valvuloplasty of calcific aortic stenosis with monofoil and trefoil balloon catheters: practical considerations

    NARCIS (Netherlands)

    S. Plante (Sylvain); M.J.B.M. van den Brand (Marcel); L.C.P. van Veen; C. di Mario (Carlo); C.E. Essed; K.J. Beatt (Kevin); P.W.J.C. Serruys (Patrick)

    1990-01-01

    textabstractIn order to evaluate the relation between balloon design (monofoil, trefoil) and valvular configuration, experimental aortic valvuloplasty was performed in four post-mortem hearts with calcific aortic stenosis of various morphology. The degree of obstruction of the aortic orifice was

  1. Uso rutinario del balón de contra-pulsación aórtica preoperatorio en pacientes con enfermedad del tronco común izquierdo sometidos a cirugía de revascularización coronaria Routine use of preoperative intra-aortic balloon pump counterpulsation (IABP implantation in patients with left main coronary artery disease undergoing coronary revascularization surgery

    Directory of Open Access Journals (Sweden)

    Andrés Fernández

    2008-08-01

    : describe mortality, length of stay and percentage of infections and sepsis in the intensive care unit, as well as the mechanical ventilation duration in patients undergoing an elective coronary revascularization surgery with or without the use of preoperative intra-aortic balloon counterpulsation. Methods: descriptive retrospective study performed in the Santa María Cardiovascular Clinic in patients undergoing elective coronary revascularization surgery with or without the use of preoperative intra-aortic balloon counterpulsation between 1999 and 2003. Postoperative behaviour in patients with severe left main disease (stenosis > 50% submitted to this surgery was observed. Results: a total of 79 patients submitted to elective surgical revascularization were analyzed. 46 underwent preoperative balloon implantation and 33 underwent surgery without previous balloon implantation. Mean age was 62 years. 67.4% of patients were 60 years or older. Main pathologies previous to surgery were arterial hypertension in 67% of the patients, and ancient acute myocardial infarction in 59%. 87% of the patients with balloon and 45.5% of those without it had severe angina (class III before surgery. In the intensive care unit 6.5% patients with balloon were infected as well as 3% of the group without balloon (p=0,49 and sepsis was found in 4,3% of the balloon group and none in the non-balloon group (p=0,23. Mortality in the intensive care unit was 2.2% in the balloon group and 3% in the non-balloon group (p=0,06. No intrahospital mortality out of the intensive care unit was reported, nor mortality at 30 days after discharge. Main length of stay in the intensive care unit was 4,13 days in the balloon group and 2,7 in the non-balloon group, with no significant statistical difference (p=0,288. The mean IABP time was 1,32 days and no vascular complications related to its use were found. Conclusions: this study suggests that with routine use of intra-aortic balloon counterpulsation previous to

  2. O uso do balão intra-aórtico no pré-operatório de cirurgia de revascularização miocárdica, associada à disfunção ventricular grave The use of preoperative intra-aortic balloon in myocardial revascularization surgery associated to severe ventricular dysfunction

    Directory of Open Access Journals (Sweden)

    Marcelo Kern

    2006-02-01

    Full Text Available OBJETIVO: Avaliar a efetividade do Balão Intra-Aórtico (BIAo profilático em cirurgia de revascularização miocárdica (CRM eletiva, para prevenir o infarto trans ou pós-operatório e para reduzir a mortalidade intra-hospitalar nos pacientes com baixa fração de ejeção ventricular esquerda. MÉTODOS: Em modelo de estudo de coorte, foram analisados 239 pacientes com fração de ejeção do ventrículo esquerdo inferior ou igual a 40%, submetidos à CRM eletiva com circulação extracorpórea (CEC, no período compreendido entre março de 1995 a fevereiro de 2001. RESULTADOS: Destes, 58 pacientes receberam BIAo pré-operatório e os demais foram operados sem assistência circulatória (grupo controle. Os dois grupos de pacientes tinham características semelhantes quanto a fatores associados aos desfechos em questão. Ocorreram 5 (8,6% óbitos no grupo com BIAo e 21 (11,6%, no grupo controle (diferença não-signifícativa. Ocorreram 2 (3,4% infartos no grupo com BIAo e 28 (15,5%, no grupo controle BIAo (p OBJECTIVE: To evaluate the effectiveness of prophylactic intra-aortic balloon (IAB in elective myocardial revascularization surgery (MRS, to prevent trans or post-operative infarction and reduce intra-hospital mortality in patients with low left ventricular ejection fraction. METHODS: Using a cohort study model, 239 patients with left ventricular ejection fraction <40%, submitted to elective MRS with extracorporeal circulation (ECC were evaluated from March 1995 to February 2001. RESULTS: Of these, 58 patients received preoperative IAB and the remainder underwent surgery without circulatory assistance (control group. The two groups of patients had similar characteristics regarding factors associated to the pertaining outcomes. There were five demises (8.6% in the group with IAB and 21 (11.6% in the control group (non-significant difference. There were 2 (3.4% infarctions in the IAB group and 28 (15.5% in the control group (p< 0

  3. Aortic annulus eccentricity before and after transcatheter aortic valve implantation: Comparison of balloon-expandable and self-expanding prostheses

    International Nuclear Information System (INIS)

    Schuhbaeck, Annika; Weingartner, Christina; Arnold, Martin; Schmid, Jasmin; Pflederer, Tobias; Marwan, Mohamed; Rixe, Johannes; Nef, Holger; Schneider, Christian; Lell, Michael; Uder, Michael; Ensminger, Stephan; Feyrer, Richard; Weyand, Michael; Achenbach, Stephan

    2015-01-01

    Highlights: • Post-implant geometry of catheter-based aortic valve prostheses is influenced by aortic valve calcification. • Balloon-expandable prostheses are more circular as compared to self-expanding prostheses. • The impact of post-implant geometry on valve function needs to be investigated. - Abstract: Introduction: The geometry of the aortic annulus and implanted transcatheter aortic valve prosthesis might influence valve function. We investigated the influence of valve type and aortic valve calcification on post-implant geometry of catheter-based aortic valve prostheses. Methods: Eighty consecutive patients with severe aortic valve stenosis (mean age 82 ± 6 years) underwent computed tomography before and after TAVI. Aortic annulus diameters were determined. Influence of prosthesis type and degree of aortic valve calcification on post-implant eccentricity were analysed. Results: Aortic annulus eccentricity was reduced in patients after TAVI (0.21 ± 0.06 vs. 0.08 ± 0.06, p < 0.0001). Post-TAVI eccentricity was significantly lower in 65 patients following implantation of a balloon-expandable prosthesis as compared to 15 patients who received a self-expanding prosthesis (0.06 ± 0.05 vs. 0.15 ± 0.07, p < 0.0001), even though the extent of aortic valve calcification was not different. After TAVI, patients with a higher calcium amount retained a significantly higher eccentricity compared to patients with lower amounts of calcium. Conclusions: Patients undergoing TAVI with a balloon-expandable prosthesis show a more circular shape of the implanted prosthesis as compared to patients with a self-expanding prosthesis. Eccentricity of the deployed prosthesis is affected by the extent of aortic valve calcification

  4. Aortic Valve Predilatation with a Small Balloon, without Rapid Pacing, prior to Transfemoral Transcatheter Aortic Valve Replacement

    Directory of Open Access Journals (Sweden)

    Anupama Shivaraju

    2018-01-01

    Full Text Available Objectives. The aim of this study is to assess the feasibility and clinical outcome of transcatheter aortic valve replacement (TAVR using aortic valve predilatation (AVPD with a small, nonocclusive balloon. Background. Balloon aortic valvuloplasty (BAV under rapid pacing is generally performed in TAVR to ensure the passage and sufficient deployment of the prosthesis in the stenotic AV. BAV may cause serious complications, such as left ventricular stunning or cerebrovascular embolism. Methods. A cohort of 50 consecutive patients with severe aortic stenosis underwent transfemoral TAVR with the Edwards Sapien 3-heart valve. All patients underwent AVPD with a small, nonocclusive balloon (12 × 60 or 14 × 60 mm without rapid pacing. Procedural data and clinical outcomes were analyzed. Results. The mean age of the cohort was 81±6 years and the mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation was 13±9. Crossing the AV and prosthesis implantation was successful in all cases. The postprocedural mean AV gradient was 12±5 mmHg. There were no cases of aortic regurgitation ≥ grade 2. No periprocedural stroke occurred. One patient (2% with chronic atrial fibrillation displayed a transient Wernicke aphasia occurring more than 24 hours after TAVR. Mortality was 0% at 30 days after procedure. Conclusion. In TAVR, AVPD with a small, nonocclusive balloon can be safely performed. By avoiding rapid pacing, this technique may be a valid alternative to traditional BAV. Whether or not the use of APVD without rapid pacing translates into less periprocedural complications needs to be assessed in future studies.

  5. Comparative Assessment of the Preventive Use of Intra-Aortic Baloon Counterpulsation and Levosimendan in Patients with Coronary Heart Disease and Low Left Ventricular Ejection Fraction

    Directory of Open Access Journals (Sweden)

    V. A. Boboshko

    2012-01-01

    Full Text Available The aim of our study was to compare the efficiency of the use of intraaortic balloon counterpulsation (IABP and levosi-mendan in patients with low left ventricular ejection fraction operated on under cardiopulmonary bypass. The study included 90 patients who were randomized into three groups according to the strategy of hemodynamic support. Group A patients received IABP 24 hours before surgery. In group B, preventive IABP was combined with intraoperative levosimendan infusion. Group C patients received intraoperative levosimendan infusion only. Hemodynamics, the markers of myocardial damage and heart failure, postoperative complications and length of hospital stay were observed. The patients treated with lev-osimendan had a more stable hemodynamic profile. Troponin I level was significantly lower in Group C six hours after cardiopulmonary bypass than that in group A. Length of stay in intensive care was significantly lower in Group C. The pre-operative concentration of BNP (>360 pg/ml is a predictor of inotropic support in the postoperative period. The results of our study indicate that the use of levosimendan in high-risk patients is effective and shows the results comparable with those of intra-aortic balloon counterpulsation.

  6. Stent-assisted, balloon-induced intimal disruption and relamination of aortic dissection in patients with Marfan syndrome: Midterm outcomes and aortic remodeling.

    Science.gov (United States)

    Faure, Elsa Madeleine; El Batti, Salma; Abou Rjeili, Marwan; Ben Abdallah, Iannis; Julia, Pierre; Alsac, Jean-Marc

    2018-05-17

    The study objective was to assess the midterm outcomes and aortic remodeling in patients with Marfan syndrome with complicated acute type B aortic dissection treated with stent-assisted, balloon-induced intimal disruption and relamination. We reviewed all patients treated with stent-assisted, balloon-induced intimal disruption and relamination for a complicated acute type B aortic dissection associated with Marfan syndrome according to the revised Ghent criteria. Between 2015 and November 2017, 7 patients with Marfan syndrome underwent stent-assisted, balloon-induced intimal disruption and relamination for a complicated acute type B aortic dissection. The median age of patients was 47 years (range, 23-70). Four patients had a history of aortic root replacement. Technical success was achieved in 100%. Three patients required an adjunctive procedure for renal artery stenting (n = 2) and iliac artery stenting (n = 1). There was no in-hospital death, 30-day postoperative stroke, spinal cord ischemia, ischemic colitis, or renal failure requiring dialysis. At a median follow-up of 15 months (range, 7-28), 1 patient required aortic arch replacement for aneurysmal degeneration associated with a type Ia endoleak at 2 years, giving a late reintervention rate of 14%. There was no other secondary endoleak. The primary visceral patency rate was 100%. There were no all-cause deaths reported. At last computed tomography scan, all patients had complete aortic remodeling of the treated thoracoabdominal aorta. Distally, at the nonstented infrarenal aortoiliac level, 6 patients had persistent false lumen flow with stable aorto-iliac diameter in 5. One patient had iliac diameter growth (27 mm diameter at last computed tomography scan). Stent-assisted, balloon-induced intimal disruption and relamination of aortic dissection in patients with Marfan syndrome is feasible, safe, and associated with an immediate and midterm persisting thoracoabdominal aortic remodeling. Copyright

  7. Factors associated with pulmonary dysfunction in patients undergoing coronary artery bypass graft surgery with use of intra-aortic balloon pump.

    Science.gov (United States)

    Amaral Gonçalves Fusatto, Helena; Castilho de Figueiredo, Luciana; Ragonete Dos Anjos Agostini, Ana Paula; Sibinelli, Melissa; Dragosavac, Desanka

    2018-01-01

    The aim of this study was to identify pulmonary dysfunction and factors associated with prolonged mechanical ventilation, hospital stay, weaning failure and mortality in patients undergoing coronary artery bypass grafting with use of intra-aortic balloon pump (IABP). This observational study analyzed respiratory, surgical, clinical and demographic variables and related them to outcomes. We analyzed 39 patients with a mean age of 61.2 years. Pulmonary dysfunction, characterized by mildly impaired gas exchange, was present from the immediate postoperative period to the third postoperative day. Mechanical ventilation time was influenced by the use of IABP and PaO2/FiO2, female gender and smoking. Intensive care unit (ICU) stay was influenced by APACHE II score and use of IABP. Mortality was strongly influenced by APACHE II score, followed by weaning failure. Pulmonary dysfunction was present from the first to the third postoperative day. Mechanical ventilation time was influenced by female gender, smoking, duration of IABP use and PaO2/FiO2 on the first postoperative day. ICU stay was influenced by APACHE II score and duration of IABP. Mortality was influenced by APACHE II score, followed by weaning failure. Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. The need for intra aortic balloon pump support following open heart surgery: risk analysis and outcome.

    LENUS (Irish Health Repository)

    Parissis, Haralabos

    2010-01-01

    BACKGROUND: The early and intermediate outcome of patients requiring intraaortic balloon pump (IABP) was studied in a cohort of 2697 adult cardiac surgical patients. METHODS: 136 patients requiring IABP (5.04%) support analysed over a 4 year period. Prospective data collection, obtained. RESULTS: The overall operative mortality was 35.3%. The "operation specific" mortality was higher on the Valve population.The mortality (%) as per time of balloon insertion was: Preoperative 18.2, Intraoperative 33.3, postoperative 58.3 (p < 0.05).The incremental risk factors for death were: Female gender (Odds Ratio (OR) = 3.87 with Confidence Intervals (CI) = 1.3-11.6), Smoking (OR = 4.88, CI = 1.23- 19.37), Preoperative Creatinine>120 (OR = 3.3, CI = 1.14-9.7), Cross Clamp time>80 min (OR = 4.16, CI = 1.73-9.98) and IABP insertion postoperatively (OR = 19.19, CI = 3.16-116.47).The incremental risk factors for the development of complications were: Poor EF (OR = 3.16, CI = 0.87-11.52), Euroscore >7 (OR = 2.99, CI = 1.14-7.88), history of PVD (OR = 4.99, CI = 1.32-18.86).The 5 years survival was 79.2% for the CABG population and 71.5% for the valve group. (Hazard ratio = 1.78, CI = 0.92-3.46). CONCLUSIONS: IABP represents a safe option of supporting the failing heart. The need for IABP especially in a high risk Valve population is associated with early unfavourable outcome, however the positive mid term results further justify its use.

  9. The need for intra aortic balloon pump support following open heart surgery: risk analysis and outcome

    Directory of Open Access Journals (Sweden)

    Apostolakis Efstratios

    2010-04-01

    Full Text Available Abstract Background The early and intermediate outcome of patients requiring intraaortic balloon pump (IABP was studied in a cohort of 2697 adult cardiac surgical patients. Methods 136 patients requiring IABP (5.04% support analysed over a 4 year period. Prospective data collection, obtained. Results The overall operative mortality was 35.3%. The "operation specific" mortality was higher on the Valve population. The mortality (% as per time of balloon insertion was: Preoperative 18.2, Intraopeartive 33.3, postoperative 58.3 (p The incremental risk factors for death were: Female gender (Odds Ratio (OR = 3.87 with Confidence Intervals (CI = 1.3-11.6, Smoking (OR = 4.88, CI = 1.23- 19.37, Preoperative Creatinine>120 (OR = 3.3, CI = 1.14-9.7, Cross Clamp time>80 min (OR = 4.16, CI = 1.73-9.98 and IABP insertion postoperatively (OR = 19.19, CI = 3.16-116.47. The incremental risk factors for the development of complications were: Poor EF (OR = 3.16, CI = 0.87-11.52, Euroscore >7 (OR = 2.99, CI = 1.14-7.88, history of PVD (OR = 4.99, CI = 1.32-18.86. The 5 years survival was 79.2% for the CABG population and 71.5% for the valve group. (Hazard ratio = 1.78, CI = 0.92-3.46. Conclusions IABP represents a safe option of supporting the failing heart. The need for IABP especially in a high risk Valve population is associated with early unfavourable outcome, however the positive mid term results further justify its use.

  10. Physiologic Tolerance of Descending Thoracic Aortic Balloon Occlusion in a Swine Model of Hemorrhagic Shock

    Science.gov (United States)

    2013-01-10

    Endovascular proximal control of ruptured abdominal aortic aneurysms: the internal aortic clamp. J Cardiovasc Surg (Torino) 2009;50(3):381. 14. Arthurs Z...Starnes B, See C, Andersen C. Clamp Before You Cut: Proximal Control of Ruptured Abdominal Aortic Aneurysms Using Endovascular Balloon Occlusion

  11. In vitro comparison of support capabilities of intra-aortic balloon pump and Impella 2.5 left percutaneous.

    Science.gov (United States)

    Schampaert, Stéphanie; van't Veer, Marcel; van de Vosse, Frans N; Pijls, Nico H J; de Mol, Bas A; Rutten, Marcel C M

    2011-09-01

    The Impella 2.5 left percutaneous (LP), a relatively new transvalvular assist device, challenges the position of the intra-aortic balloon pump (IABP), which has a long record in supporting patients after myocardial infarction and cardiac surgery. However, while more costly and more demanding in management, the advantages of the Impella 2.5 LP are yet to be established. The aim of this study was to evaluate the benefits of the 40 cc IABP and the Impella 2.5 LP operating at 47,000 rpm in vitro, and compare their circulatory support capabilities in terms of cardiac output, coronary flow, cardiac stroke work, and arterial blood pressure. Clinical scenarios of cardiogenic preshock and cardiogenic shock (CS), with blood pressure depression, lowered cardiac output, and constant heart rate of 80 bpm, were modeled in a model-controlled mock circulation, featuring a systemic, pulmonary, and coronary vascular bed. The ventricles, represented by servomotor-operated piston pumps, included the Frank-Starling mechanism. The systemic circulation was modeled with a flexible tube having close-to-human aortic dimensions and compliance properties. Proximally, it featured a branch mimicking the brachiocephalic arteries and a physiological correct coronary flow model. The rest of the systemic and pulmonary impedance was modeled by four-element Windkessel models. In this system, the enhancement of coronary flow and blood pressure was tested with both support systems under healthy and pathological conditions. Hemodynamic differences between the IABP and the Impella 2.5 LP were small. In our laboratory model, both systems approximately yielded a 10% cardiac output increase and a 10% coronary flow increase. However, since the Impella 2.5 LP provided significantly better left ventricular unloading, the circulatory support capabilities were slightly in favor of the Impella 2.5 LP. On the other hand, pulsatility was enhanced with the IABP and lowered with the Impella 2.5 LP. The support

  12. Aortic annulus and ascending aorta: Comparison of preoperative and periooperative measurement in patients with aortic stenosis

    International Nuclear Information System (INIS)

    Smid, Michal; Ferda, Jiri; Baxa, Jan; Cech, Jakub; Hajek, Tomas; Kreuzberg, Boris; Rokyta, Richard

    2010-01-01

    Background: Precise determination of the aortic annulus size constitutes an integral part of the preoperative evaluation prior to aortic valve replacement. It enables the estimation of the size of prosthesis to be implanted. Knowledge of the size of the ascending aorta is required in the preoperative analysis and monitoring of its dilation enables the precise timing of the operation. Our goal was to compare the precision of measurement of the aortic annulus and ascending aorta using magnetic resonance (MR), multidetector-row computed tomography (MDCT), transthoracic echocardiography (TTE), and transoesophageal echocardiography (TEE) in patients with degenerative aortic stenosis. Methods and results: A total of 15 patients scheduled to have aortic valve replacement were enrolled into this prospective study. TTE was performed in all patients and was supplemented with TEE, CT and MR in the majority of patients. The values obtained were compared with perioperative measurements. For the measurement of aortic annulus, MR was found to be the most precise technique, followed by MDCT, TTE, and TEE. For the measurement of ascending aorta, MR again was found to be the most precise technique, followed by MDCT, TEE, and TTE. Conclusion: In our study, magnetic resonance was found to be the most precise technique for the measurement of aortic annulus and ascending aorta in patients with severe degenerative aortic stenosis.

  13. The outcomes of intra-aortic balloon pump usage in patients with acute myocardial infarction: a comprehensive meta-analysis of 33 clinical trials and 18,889 patients

    Directory of Open Access Journals (Sweden)

    Fan ZG

    2016-03-01

    Full Text Available Zhong-Guo Fan,1,* Xiao-Fei Gao,1,2,* Li-Wen Chen,1 Xiao-Bo Li,1,2 Ming-Xue Shao,1,2 Qian Ji,1 Hao Zhu,1 Yi-Zhi Ren,1 Shao-Liang Chen,1,2 Nai-Liang Tian1,2 1Department of Cardiology, Nanjing First Hospital, Nanjing Medical University, 2Department of Cardiology, Nanjing Heart Center, Nanjing, People’s Republic of China *These authors contributed equally to this work Background: The effects of intra-aortic balloon pump (IABP usage in patients with acute myocardial infarction remain controversial. This study sought to evaluate the outcomes of IABP usage in these patients.Methods: Medline, EMBASE, and other internet sources were searched for relevant clinical trials. The primary efficacy endpoints (in-hospital, midterm, and long-term mortality and secondary endpoints (reinfarction, recurrent ischemia, and new heart failure in the hospital as well as safety endpoints (severe bleeding requiring blood transfusion and stroke in-hospital were subsequently analyzed.Results: Thirty-three clinical trials involving 18,889 patients were identified. The risk of long-term mortality in patients suffering from acute myocardial infarction was significantly decreased following IABP use (odds ratio [OR] 0.66, 95% confidence interval [CI]: 0.48–0.91, P=0.010. Both in-hospital and midterm mortality did not differ significantly between the IABP use group and no IABP use group (in-hospital: OR 0.87, 95% CI: 0.59–1.28, P=0.479; midterm: OR 1.12, 95% CI: 0.53–2.38, P=0.768. IABP insertion was not associated with the risk reduction of reinfarction, recurrent ischemia, or new heart failure. However, IABP use increased the risk of severe bleeding requiring blood transfusion (OR 2.05, 95% CI: 1.29–3.25, P=0.002 and stroke (OR 1.71, 95% CI: 1.04–2.82, P=0.035. In the thrombolytic therapy and cardiogenic shock subgroups, reduced mortality rates following IABP use were observed.Conclusion: IABP insertion is associated with feasible benefits with respect to long

  14. SU-C-18C-02: Specifcation of X-Ray Projection Angles Which Are Aligned with the Aortic Valve Plane From a Planar Image of a Valvuloplasty Balloon Inflated Across the Aortic Valve

    Energy Technology Data Exchange (ETDEWEB)

    Fetterly, K; Mathew, V [Mayo Clinic, Rochester, MN (United States)

    2014-06-01

    Purpose: Transcatheter aortic valve replacement (TAVR) procedures provide a method to implant a prosthetic aortic valve via a minimallyinvasive, catheter-based procedure. TAVR procedures require use of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane to minimize prosthetic valve positioning error due to x-ray imaging parallax. The purpose of this work is to calculate the continuous range of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane from a single planar image of a valvuloplasty balloon inflated across the aortic valve. Methods: Computational methods to measure the 3D angular orientation of the aortic valve were developed. Required inputs include a planar x-ray image of a known valvuloplasty balloon inflated across the aortic valve and specifications of x-ray imaging geometry from the DICOM header of the image. A-priori knowledge of the species-specific typical range of aortic orientation is required to specify the sign of the angle of the long axis of the balloon with respect to the x-ray beam. The methods were validated ex-vivo and in a live pig. Results: Ex-vivo experiments demonstrated that the angular orientation of a stationary inflated valvuloplasty balloon can be measured with precision less than 1 degree. In-vivo pig experiments demonstrated that cardiac motion contributed to measurement variability, with precision less than 3 degrees. Error in specification of x-ray geometry directly influences measurement accuracy. Conclusion: This work demonstrates that the 3D angular orientation of the aortic valve can be calculated precisely from a planar image of a valvuloplasty balloon inflated across the aortic valve and known x-ray geometry. This method could be used to determine appropriate c-arm angular projections during TAVR procedures to minimize x-ray imaging parallax and thereby minimize prosthetic valve positioning errors.

  15. SU-C-18C-02: Specifcation of X-Ray Projection Angles Which Are Aligned with the Aortic Valve Plane From a Planar Image of a Valvuloplasty Balloon Inflated Across the Aortic Valve

    International Nuclear Information System (INIS)

    Fetterly, K; Mathew, V

    2014-01-01

    Purpose: Transcatheter aortic valve replacement (TAVR) procedures provide a method to implant a prosthetic aortic valve via a minimallyinvasive, catheter-based procedure. TAVR procedures require use of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane to minimize prosthetic valve positioning error due to x-ray imaging parallax. The purpose of this work is to calculate the continuous range of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane from a single planar image of a valvuloplasty balloon inflated across the aortic valve. Methods: Computational methods to measure the 3D angular orientation of the aortic valve were developed. Required inputs include a planar x-ray image of a known valvuloplasty balloon inflated across the aortic valve and specifications of x-ray imaging geometry from the DICOM header of the image. A-priori knowledge of the species-specific typical range of aortic orientation is required to specify the sign of the angle of the long axis of the balloon with respect to the x-ray beam. The methods were validated ex-vivo and in a live pig. Results: Ex-vivo experiments demonstrated that the angular orientation of a stationary inflated valvuloplasty balloon can be measured with precision less than 1 degree. In-vivo pig experiments demonstrated that cardiac motion contributed to measurement variability, with precision less than 3 degrees. Error in specification of x-ray geometry directly influences measurement accuracy. Conclusion: This work demonstrates that the 3D angular orientation of the aortic valve can be calculated precisely from a planar image of a valvuloplasty balloon inflated across the aortic valve and known x-ray geometry. This method could be used to determine appropriate c-arm angular projections during TAVR procedures to minimize x-ray imaging parallax and thereby minimize prosthetic valve positioning errors

  16. Clinical Utility of Preoperative Computed Tomography in Patients With Endometrial Cancer.

    Science.gov (United States)

    Bogani, Giorgio; Gostout, Bobbie S; Dowdy, Sean C; Multinu, Francesco; Casarin, Jvan; Cliby, William A; Frigerio, Luigi; Kim, Bohyun; Weaver, Amy L; Glaser, Gretchen E; Mariani, Andrea

    2017-10-01

    The aim of this study was to determine the clinical utility of routine preoperative pelvic and abdominal computed tomography (CT) examinations in patients with endometrial cancer (EC). We retrospectively reviewed records from patients with EC who underwent a preoperative endometrial biopsy and had surgery at our institution from January 1999 through December 2008. In the subset with an abdominal CT scan obtained within 3 months before surgery, we evaluated the clinical utility of the CT scan. Overall, 224 patients (18%) had a preoperative endometrial biopsy and an available CT scan. Gross intra-abdominal disease was observed in 10% and 20% of patients with preoperative diagnosis of endometrioid G3 and type II EC, respectively, whereas less than 5% of patients had a preoperative diagnosis of hyperplasia or low-grade EC. When examining retroperitoneal findings, we observed that a negative CT scan of the pelvis did not exclude the presence of pelvic node metastasis. Alternately, a negative CT scan in the para-aortic area generally reduced the probability of finding para-aortic dissemination but with an overall low sensitivity (42%). However, the sensitivity for para-aortic dissemination was as high as 67% in patients with G3 endometrioid cancer. In the case of negative para-aortic nodes in the CT scan, the risk of para-aortic node metastases decreased from 18.8% to 7.5% in patients with endometrioid G3 EC. Up to 15% of patients with endometrioid G3 cancer had clinically relevant incidental findings that necessitated medical or surgical intervention. In patients with endometrioid G3 and type II EC diagnosed by the preoperative biopsy, CT scans may help guide the operative plan by facilitating preoperative identification of gross intra-abdominal disease and enlarged positive para-aortic nodes that are not detectable during physical examinations. In addition, CT may reveal other clinically relevant incidental findings.

  17. Temporary Percutaneous Aortic Balloon Occlusion to Enhance Fluid Resuscitation Prior to Definitive Embolization of Post-Traumatic Liver Hemorrhage

    International Nuclear Information System (INIS)

    Matsuoka, Shin; Uchiyama, Katsuhiro; Shima, Hideki; Ohishi, Sonomi; Nojiri, Yoko; Ogata, Hitoshi

    2001-01-01

    We successfully stabilized severe hemorrhagic shock following traumatic liver injury by percutaneous transcarotid supraceliac aortic occlusion with a 5 Fr balloon catheter. Then we were able to perform transfemoral embolization therapy of the hepatic arterial bleeding source. Transient aortic occlusion using a balloon catheter appears to be a useful adjunct in select cases where stabilization of the patient is necessary to allow successful selective embolization of the bleeding source

  18. Preoperative computer tomography evaluation in transcatheter aortic valve replacement (TAVI)

    International Nuclear Information System (INIS)

    Groudeva, V.; Stoynova, V.; Trendafilova, D.; Dzhorgova, Y.; Nachev, G.

    2014-01-01

    Transcatheter aortic valve replacement is rapidly emerging technique alternative to surgery in high risk patients. Imaging and especially computer tomography is important in preoperative assessment of the aortic ring and the prosthetic valve choice. The aim of this study is to share authors initial experience in CT assessment of the aortic ring prior to Transcatheter aortic valve replacement. 49 patients (mean age 76,55) underwent 320 rows MDCT (Acquilon One) prior TAVI. Protocol involved scanning from thoracic inlet to common femoral arteries. Aortic root size, aortic diameter at the level of coronary sinuses and the sinotubular junction and distance to coronary ostia were evaluated on a Vitrea work station. MDCT established maximal aortic ring diameter from 18 to 31 mm mean 25,04 mm while the lesser rate was from 16 to 21 mm. Accordingly positioned prostheses were in 34,75% No. 23, in 49% - No. 26 and in16,3% - No. 29. MDCT is crucial in aortic valve assessment prior to TAVI in experienced hands and multidisciplinary team. (authors) Key words: TRANSCATHETER AORTIC VALVE REPLACEMENT (TAVI). MDCT AORTIC VALVE ASSESSMENT

  19. Clinical and hemodynamic effects of intra-aortic balloon pump therapy in chronic heart failure patients with cardiogenic shock.

    Science.gov (United States)

    Fried, Justin A; Nair, Abhinav; Takeda, Koji; Clerkin, Kevin; Topkara, Veli K; Masoumi, Amirali; Yuzefpolskaya, Melana; Takayama, Hiroo; Naka, Yoshifumi; Burkhoff, Daniel; Kirtane, Ajay; Dimitrios Karmpaliotis, S M; Moses, Jeffrey; Colombo, Paolo C; Garan, A Reshad

    2018-03-20

    The role of the intra-aortic balloon pump (IABP) in acute decompensated heart failure (HF) with cardiogenic shock (CS) is largely undefined. In this study we sought to assess the hemodynamic and clinical response to IABP in chronic HF patients with CS and identify predictors of response to this device. We retrospectively reviewed all patients undergoing IABP implantation from 2011 to 2016 at our institution to identify chronic HF patients with acute decompensation and CS (cardiac index <2.2 liters/min/m 2 and systolic blood pressure <90 mm Hg or need for vasoactive medications to maintain this level). Clinical deterioration on IABP was defined as failure to bridge to either discharge on medical therapy or durable heart replacement therapy (HRT; durable left ventricular assist device or heart transplant) with IABP alone. We identified 132 chronic HF patients with IABP placed after decompensation with hemodynamic evidence of CS. Overall 30-day survival was 84.1%, and 78.0% of patients were successfully bridged to HRT or discharge without need for escalation of device support. The complication rate during IABP support was 2.3%. Multivariable analysis identified ischemic cardiomyopathy (odds ratio [OR] 3.24, 95% confidence interval [CI] 1.16 to 9.06; p = 0.03) and pulmonary artery pulsatility index (PAPi) <2.0 (OR 5.04, 95% CI 1.86 to 13.63; p = 0.001) as predictors of clinical deterioration on IABP. Overall outcomes with IABP in acute decompensated chronic HF patients are encouraging, and IABP is a reasonable first-line device for chronic HF patients with CS. Baseline right ventricular function, as measured by PAPi, is a major predictor of outcomes with IABP in this population. Copyright © 2018 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  20. Measurements of Intra‐Aortic Balloon Wall Movement During Inflation and Deflation: Effects of Angulation

    Science.gov (United States)

    Bruti, Gianpaolo; Kolyva, Christina; Pepper, John R.

    2015-01-01

    Abstract The intra‐aortic balloon pump (IABP) is a ventricular assist device that is used with a broad range of pre‐, intra‐, and postoperative patients undergoing cardiac surgery. Although the clinical efficacy of the IABP is well documented, the question of reduced efficacy when patients are nursed in the semi‐recumbent position remains outstanding. The aim of the present work is therefore to investigate the underlying mechanics responsible for the loss of IABP performance when operated at an angle to the horizontal. Simultaneous recordings of balloon wall movement, providing an estimate of its diameter (D), and fluid pressure were taken at three sites along the intra‐aortic balloon (IAB) at 0 and 45°. Flow rate, used for the calculation of displaced volume, was also recorded distal to the tip of the balloon. An in vitro experimental setup was used, featuring physiological impedances on either side of the IAB ends. IAB inflation at an angle of 45° showed that D increases at the tip of the IAB first, presenting a resistance to the flow displaced away from the tip of the balloon. The duration of inflation decreased by 15.5%, the inflation pressure pulse decreased by 9.6%, and volume decreased by 2.5%. Similarly, changing the position of the balloon from 0 to 45°, the balloon deflation became slower by 35%, deflation pressure pulse decreased by 14.7%, and volume suctioned was decreased by 15.2%. IAB wall movement showed that operating at 45° results in slower deflation compared with 0°. Slow wall movement, and changes in inflation and deflation onsets, result in a decreased volume displacement and pressure pulse generation. Operating the balloon at an angle to the horizontal, which is the preferred nursing position in intensive care units, results in reduced IAB inflation and deflation performance, possibly compromising its clinical benefits. PMID:25959284

  1. Inflation and deflation timing of the AutoCAT 2 WAVE intra-aortic balloon pump using the autoPilot mode in a clinical setting.

    Science.gov (United States)

    Bakker, E W M; Visser, K; van der Wal, A; Kuiper, M A; Koopmans, M; Breedveld, R

    2012-09-01

    The primary goal of this observational clinical study was to register the occurrence of incorrect inflation and deflation timing of an intra-aortic balloon pump in autoPilot mode. The secondary goal was to identify possible causes of incorrect timing. During IABP assistance of 60 patients, every four hours a strip was printed with the IABP frequency set to 1:2. Strips were examined for timing discrepancies beyond 40 ms from the dicrotic notch (inflation) and the end of the diastolic phase (deflation). In this way, 320 printed strips were examined. A total of 52 strips (16%) showed incorrect timing. On 24 of these strips, the incorrect timing was called incidental, as it showed on only one or a few beats. The other 28 cases of erroneous timing were called consistent, as more than 50% of the beats on the strip showed incorrect timing. We observed arrhythmia in 69% of all cases of incorrect timing. When timing was correct, arrhythmia was found on 13 (5%) of 268 strips. A poor quality electrocardiograph (ECG) signal showed on 37% of all strips with incorrect timing and 11% of all strips with proper timing. We conclude that inflation and deflation timing of the IABP is not always correct when using the autoPilot mode. The quality of the ECG input signal and the occurrence of arrhythmia appear to be related to erroneous timing. Switching from autoPilot mode to operator mode may not always prevent incorrect timing.

  2. High-pressure balloon dilation in a dog with supravalvular aortic stenosis.

    Science.gov (United States)

    Pinkos, A; Stauthammer, C; Rittenberg, R; Barncord, K

    2017-02-01

    A 6-month-old female intact Goldendoodle was presented for diagnostic work up of a grade IV/VI left basilar systolic heart murmur. An echocardiogram was performed and revealed a ridge of tissue distal to the aortic valve leaflets at the sinotubular junction causing an instantaneous pressure gradient of 62 mmHg across the supravalvular aortic stenosis and moderate concentric hypertrophy of the left ventricle. Intervention with a high-pressure balloon dilation catheter was pursued and significantly decreased the pressure gradient to 34 mmHg. No complications were encountered. The patient returned in 5 months for re-evaluation and static long-term reduction in the pressure gradient was noted. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Caesarean section combined with temporary aortic balloon occlusion followed by uterine artery embolisation for the management of placenta accreta

    International Nuclear Information System (INIS)

    Duan, X.-H.; Wang, Y.-L.; Han, X.-W.; Chen, Z.-M.; Chu, Q.-J.; Wang, L.; Hai, D.-D.

    2015-01-01

    Aim: To determine the efficacy and safety of caesarean section combined with temporary aortic balloon occlusion followed by uterine artery embolisation (UAE) for the treatment of patients with placenta accreta. Materials and methods: This retrospective study involved 42 patients with placenta accreta. All patients underwent caesarean section combined with temporary aortic balloon occlusion followed by UAE through the right femoral approach. Results: All patients were confirmed to have placenta praevia and accreta, including five patients with placenta percreta, at the time of delivery. The technical success rate of the combined treatment was 97.6% (41/42). Forty-one patients underwent successful caesarean section with conservation of the uterus. Hysterectomy was required in one (3.1%) patient. The amount of blood loss and blood transfusion, and the operation time were was 586 ± 355 ml, 422 ± 83 ml and 65.5 ± 10.6 minutes, respectively. The mean postoperative hospital stay, occlusion time and fetal radiation dose were 5.5 ± 2.6 days, 22.4 ± 7.2 minutes and 4.2 ± 2.9 mGy, respectively. There were no significant changes before and 7 days after the endovascular procedure in creatinine levels (56.8 ± 13.8 μmol/l versus 63.4 ± 16.7 μmol/l, p = 0.09) or urea nitrogen (6.3 ± 2.5 μmol/l versus 7.4 ± 3.8 μmol/l, p = 0.17). There were no access-site complications after the endovascular procedure and no complications related to the intervention during follow-up. Conclusion: Temporary aortic balloon occlusion followed by UAE can effectively control postpartum haemorrhage during placental dissection, and reduce transfusion requirements, hysterectomy rate, and operation time in patients with placenta accreta. -- Highlights: •Aortic balloon occlusion can overcome the collateral flow from other arteries. •UAE can effectively manage secondary postpartum haemorrhage. •The aortic balloon can rapidly and easily insert. •The mean

  4. Preoperative Localization of Mediastinal Parathyroid Adenoma with Intra-arterial Methylene Blue

    Energy Technology Data Exchange (ETDEWEB)

    Salman, Rida; Sebaaly, Mikhael G. [American University of Beirut Medical Center, Department of Diagnostic Radiology (Lebanon); Wehbe, Mohammad Rachad; Sfeir, Pierre; Khalife, Mohamad [American University of Beirut Medical Center, Department of General Surgery (Lebanon); Al-Kutoubi, Aghiad, E-mail: mk00@aub.edu.lb [American University of Beirut Medical Center, Department of Diagnostic Radiology (Lebanon)

    2017-06-15

    Ectopic parathyroid is found in 16% of patients with hyperparathyroidism. 2% of ectopic parathyroid adenomas are not accessible to standard cervical excision. In such cases, video-assisted thoracoscopic resection is the recommended definitive treatment. We present a case of mediastinal parathyroid adenoma localized preoperatively by injecting methylene blue within a branch of the internal mammary artery that is supplying the adenoma. Intra-arterial methylene blue injection facilitated visualization and resection of the adenoma. The preoperative intra-arterial infusion of methylene blue appears to be an effective and safe method for localization of ectopic mediastinal parathyroid adenomas and allows rapid identification during thoracoscopic resection.

  5. Preoperative renal function and surgical outcomes in patients with acute type A aortic dissection†.

    Science.gov (United States)

    Imasaka, Ken-ichi; Tayama, Eiki; Tomita, Yukihiro

    2015-04-01

    There are few data concerning the impact of preoperative renal function, assessed using estimated glomerular filtration rate, on surgical outcomes following acute type A aortic dissection. We investigated the accuracy of estimated glomerular filtration rate (in ml/min/1.73 m(2)) in predicting in-hospital mortality and postoperative renal replacement therapy in such cases. We reviewed 114 consecutive patients with non-dialysis-dependent renal dysfunction who underwent thoracic aortic surgery for acute type A aortic dissection between 1997 and 2012. Preoperative renal function was categorized as normal (estimated glomerular filtration rate >90; n = 15) or as mild (60-89; n = 39), moderate I (45-59; n = 39), moderate II (30-44; n = 14) or severe (15-29; n = 7) renal dysfunction. In-hospital mortality was 14.9%. Eighteen (15.8%) of 114 patients required renal replacement therapy. A more severe stage stratified by preoperative estimated glomerular filtration rate levels could effectively predict postoperative renal replacement therapy (area under the receiver operating characteristic curve 0.786). The best cut-off value of estimated glomerular filtration rate for predicting postoperative renal replacement therapy was 60 (sensitivity 95%, specificity 59%). On multiple regression analysis, the independent preoperative and intraoperative risk factors for postoperative renal replacement therapy were estimated glomerular filtration rate (P replacement (P replacement therapy (OR, 5.47; P regression analysis. Preoperative estimated glomerular filtration rate can effectively predict the need for renal replacement therapy after surgery for acute type A aortic dissection. However, it is not an effective diagnostic tool to predict in-hospital mortality. The complexity of the characteristics of patients who undergo surgical procedures may make prediction of surgical outcomes difficult. Risk models to predict hospital mortality and morbidities are needed to assist clinicians in

  6. Agreement between pre-operative and intra-operative bacteriological samples in 85 chronic peri-prosthetic infections.

    Science.gov (United States)

    Matter-Parrat, V; Ronde-Oustau, C; Boéri, C; Gaudias, J; Jenny, J-Y

    2017-04-01

    Whether pre-operative microbiological sampling contributes to the management of chronic peri-prosthetic infection remains controversial. We assessed agreement between the results of pre-operative and intra-operative samples in patients undergoing single-stage prosthesis exchange to treat chronic peri-prosthetic infection. Agreement between pre-operative and intra-operative samples exceeds 75% in patients undergoing single-stage exchange of a hip or knee prosthesis to treat chronic peri-prosthetic infection. This single-centre retrospective study included 85 single-stage prosthesis exchange procedures in 82 patients with chronic peri-prosthetic infection at the hip or knee. Agreement between pre-operative and intra-operative sample results was evaluated. Changes to the initial antibiotic regimen made based on the intra-operative sample results were recorded. Of 149 pre-operative samples, 109 yielded positive cultures, in 75/85 cases. Of 452 intra-operative samples, 354 yielded positive cultures, in 85/85 cases. Agreement was complete in 54 (63%) cases and partial in 9 (11%) cases; there was no agreement in the remaining 22 (26%) cases. The complete agreement rate was significantly lower than 75% (P=0.01). The initial antibiotic regimen was inadequate in a single case. Pre-operative sampling may contribute to the diagnosis of peri-prosthetic infection but is neither necessary nor sufficient to confirm the diagnosis and identify the causative agent. The spectrum of the initial antibiotic regimen cannot be safely narrowed based on the pre-operative sample results. We suggest the routine prescription of a probabilistic broad-spectrum antibiotic regimen immediately after the prosthesis exchange, even when a pathogen was identified before surgery. IV, retrospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  7. Immediate and Short-term Follow-Up of Aortic Coarctation Balloon Angioplasty and Stenting

    Directory of Open Access Journals (Sweden)

    Hasan Mottaghi Moghadam

    2017-12-01

    Full Text Available Background Aortic Coarcatation (CoA is one of the congenital heart diseases with the rate of 5-8% of Coronary heart diseases(CHDs. Balloon angioplasty is now one of the effective way of treatment for CoA, native or Re-coarctation (Re-CoA. We aimed to assess the immediate, and short term response to angioplasty and stenting, and also complications. Materials and Methods Balloon angioplasty with our without stenting was performed for 53 patients with native or Re-coarcatation angioplasty (39 balloon angioplasty alone, and 14 balloon and stenting. Pressure gradient across the CoA segment was measured initially by Echo and pre, and Post procedure. Echocardiography was also used for follow up assessment during 24 hours, one and 6 months afterward. Results Among 53 patients, 52.8% were male. There were 98.2% native and 3.8% Re-CoA. The mean age of patients was 8.65 ± 8.37 years, and the mean weight was 25.82±20.73 kg. The mean pressure gradient acrossthe CoA site before angioplasty was 24.88±12.32, and post procedure gradient was 4.77±6.42 (p

  8. The effects of preoperative cardiology consultation prior to elective abdominal aortic aneurysm repair on patient morbidity.

    Science.gov (United States)

    Boniakowski, Anna E; Davis, Frank M; Phillips, Amanda R; Robinson, Adina B; Coleman, Dawn M; Henke, Peter K

    2017-08-01

    Objectives The relationship between preoperative medical consultations and postoperative complications has not been extensively studied. Thus, we investigated the impact of preoperative consultation on postoperative morbidity following elective abdominal aortic aneurysm repair. Methods A retrospective review was conducted on 469 patients (mean age 72 years, 20% female) who underwent elective abdominal aortic aneurysm repair from June 2007 to July 2014. Data elements included detailed medical history, preoperative cardiology consultation, and postoperative complications. Primary outcomes included 30-day morbidity, consult-specific morbidity, and mortality. A bivariate probit regression model accounting for the endogeneity of binary preoperative medical consult and patient variability was estimated with a maximum likelihood function. Results Eighty patients had preoperative medical consults (85% cardiology); thus, our analysis focuses on the effect of cardiac-related preoperative consults. Hyperlipidemia, increased aneurysm size, and increased revised cardiac risk index increased likelihood of referral to cardiology preoperatively. Surgery type (endovascular versus open repair) was not significant in development of postoperative complications when controlling for revised cardiac risk index ( p = 0.295). After controlling for patient comorbidities, there was no difference in postoperative cardiac-related complications between patients who did and did not undergo cardiology consultation preoperatively ( p = 0.386). Conclusions When controlling for patient disease severity using revised cardiac risk index risk stratification, preoperative cardiology consultation is not associated with postoperative cardiac morbidity.

  9. Laser Fenestration of Aortic Stent-Grafts Followed by Noncompliant vs Cutting Balloon Dilation: A Scanning Electron Microscopy Study.

    Science.gov (United States)

    Lin, Jing; Parikh, Niraj; Udgiri, Naval; Wang, Shaoxia; Miller, Daniel F; Li, Chaojing; Panneton, Jean; Nutley, Mark; Zhang, Ze; Huang, Yunfan; Lu, Jun; Zhang, Jingyi; Wang, Lu; Guidoin, Robert

    2018-06-01

    To examine the effects of in situ laser fenestration and subsequent balloon dilation (noncompliant vs cutting) on the graft fabric of 4 aortic stent-graft models. In an in vitro setup, the Zenith TX2, Talent, Endurant, and Anaconda aortic stent-grafts (all made of polyester graft material) were subjected to laser fenestration with a 2.3-mm-diameter probe at low and high energy in a physiologic saline solution followed by balloon dilation of the hole. For the first series of tests, 6-mm-diameter noncompliant balloons were used and replaced for the second series by 6-mm-diameter cutting balloons. Each procedure was performed 5 times (5 fenestrations per balloon type). The fenestrations were examined visually and with light and scanning electron microscopy. Each fenestration demonstrated various degrees of fraying and/or tearing regardless of the device. The monofilament twill weave of the Talent endograft tore in the warp direction up to 7.09±0.46 mm at high energy compared with 2.41±0.26 mm for the Endurant multifilament device. The fenestrations of the 3 endografts with multifilament weave (Zenith, Anaconda, and Endurant) showed more fraying; fenestration areas in the multifilament Endurant were >10 mm 2 at low and high energy. The fenestrations were free of melted fibers, but minor blackening of the filaments was observed in all devices. Overall, the cutting balloons resulted in worse tearing and damage. Of note, the edges of the dilated laser-formed fenestrations of the Talent and the Endurant grafts demonstrated evidence of additional shredded yarns. In situ fenestration does not cause any melting of the polyester; however, the observed structural damage to the fabric construction must be carefully considered. Cutting balloons caused various levels of tearing compared to the noncompliant balloons and cannot be recommended for use in this application. Rather, noncompliant balloons should be employed, but only with endografts constructed from multifilament yarns

  10. Incremental balloon deflation following complete resuscitative endovascular balloon occlusion of the aorta results in steep inflection of flow and rapid reperfusion in a large animal model of hemorrhagic shock.

    Science.gov (United States)

    Davidson, Anders J; Russo, Rachel M; Ferencz, Sarah-Ashley E; Cannon, Jeremy W; Rasmussen, Todd E; Neff, Lucas P; Johnson, M Austin; Williams, Timothy K

    2017-07-01

    To avoid potential cardiovascular collapse after resuscitative endovascular balloon occlusion of the aorta (REBOA), current guidelines recommend methodically deflating the balloon for 5 minutes to gradually reperfuse distal tissue beds. However, anecdotal evidence suggests that this approach may still result in unpredictable aortic flow rates and hemodynamic instability. We sought to characterize aortic flow dynamics following REBOA as the balloon is deflated in accordance with current practice guidelines. Eight Yorkshire-cross swine were splenectomized, instrumented, and subjected to rapid 25% total blood volume hemorrhage. After 30 minutes of shock, animals received 60 minutes of Zone 1 REBOA with a low-profile REBOA catheter. During subsequent resuscitation with shed blood, the aortic occlusion balloon was gradually deflated in stepwise fashion at the rate of 0.5 mL every 30 seconds until completely deflated. Aortic flow rate and proximal mean arterial pressure (MAP) were measured continuously over the period of balloon deflation. Graded balloon deflation resulted in variable initial return of aortic flow (median, 78 seconds; interquartile range [IQR], 68-105 seconds). A rapid increase in aortic flow during a single-balloon deflation step was observed in all animals (median, 819 mL/min; IQR, 664-1241 mL/min) and corresponded with an immediate decrease in proximal MAP (median, 30 mm Hg; IQR, 14.5-37 mm Hg). Total balloon volume and time to return of flow demonstrated no correlation (r = 0.016). This study is the first to characterize aortic flow during balloon deflation following REBOA. A steep inflection point occurs during balloon deflation that results in an abrupt increase in aortic flow and a concomitant decrease in MAP. Furthermore, the onset of distal aortic flow was inconsistent across study animals and did not correlate with initial balloon volume or relative deflation volume. Future studies to define the factors that affect aortic flow during balloon

  11. Preoperative methylprednisolone enhances recovery after endovascular aortic repair

    DEFF Research Database (Denmark)

    de la Motte, Louise; Kehlet, Henrik; Vogt, Katja

    2014-01-01

    OBJECTIVE: To evaluate effects of preoperative high-dose glucocorticoid on the inflammatory response and recovery after endovascular aortic aneurysm repair (EVAR). BACKGROUND: The postimplantation syndrome after EVAR may delay recovery due to the release of proinflammatory mediators....... Glucocorticoids may reduce postoperative inflammatory responses and enhance recovery, but with limited information on EVAR. METHODS: A single-center, randomized, double-blind, placebo-controlled trial of 153 patients undergoing elective EVAR between November 2009 and January 2013. Patients received 30 mg.......001) and fulfillment of discharge criteria was shorter [2 days (IQR = 2-4 days) vs 3 days (IQR = 3-4 days)] (P factor receptor were also reduced (P

  12. Wave energy patterns of counterpulsation: a novel approach with wave intensity analysis.

    Science.gov (United States)

    Lu, Pong-Jeu; Yang, Chi-Fu Jeffrey; Wu, Meng-Yu; Hung, Chun-Hao; Chan, Ming-Yao; Hsu, Tzu-Cheng

    2011-11-01

    In counterpulsation, diastolic augmentation increases coronary blood flow and systolic unloading reduces left ventricular afterload. We present a new approach with wave intensity analysis to revisit and explain counterpulsation principles. In an acute porcine model, a standard intra-aortic balloon pump was placed in descending aorta in 4 pigs. We measured pressure and velocity with probes in left anterior descending artery and aorta during and without intra-aortic balloon pump assistance. Wave intensities of aortic and left coronary waves were derived from pressure and flow measurements with synchronization correction. We identified predominating waves in counterpulsation. In the aorta, during diastolic augmentation, intra-aortic balloon inflation generated a backward compression wave, with a "pushing" effect toward the aortic root that translated to a forward compression wave into coronary circulation. During systolic unloading, intra-aortic balloon pump deflation generated a backward expansion wave that "sucked" blood from left coronary bed into the aorta. While this backward expansion wave translated to reduced left ventricular afterload, the "sucking" effect resulted in left coronary blood steal, as demonstrated by a forward expansion wave in left anterior descending coronary flow. The waves were sensitive to inflation and deflation timing, with just 25 ms delay from standard deflation timing leading to weaker forward expansion wave and less coronary regurgitation. Intra-aortic balloon pumps generate backward-traveling waves that predominantly drive aortic and coronary blood flow during counterpulsation. Wave intensity analysis of arterial circulations may provide a mechanism to explain diastolic augmentation and systolic unloading of intra-aortic balloon pump counterpulsation. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  13. The effect of endoleak on intra-aneurysmal pressure after EVE for abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Huang Sheng; Jing Zaiping; Mei Zhijun; Lu Qingsheng; Zhao Jun; Zhang Suzhen; Zhao Xin; Cai Lili; Tang Jingdong; Xiong Jiang; Liao Mingfang

    2003-01-01

    Objective: To investigate the intra-aneurysmal pressure curve in the presence of endoleak after endovascular exclusion (EVE) for abdominal aortic aneurysm (AAA). Methods: Infrarenal aortic aneurysms were created with bovine jugular vein segments or patches. Then they were underwent incomplete endovascular exclusion of the aneurysm and formation of endoleaks. The pressures of blood flow outside the graft into the sac were measured. Results: The intrasac pressure was higher than systemic pressure in the presence of endoleak. After sealing the endoleak, pressure decreased significantly, and the pressure cure showed approximately linear. Conclusion: The change of intra-aneurysmal pressure curve reflected the load on aneurysmal wall after EVE, and can also help to determine the endoleak existence

  14. Preoperative Evaluation and Endovascular Procedure of Intraoperative Aneurysm Rupture During Thoracic Endovascular Aortic Repair

    Energy Technology Data Exchange (ETDEWEB)

    Zha, Bin-Shan, E-mail: binszha2013@163.com; Zhu, Hua-Gang, E-mail: huagzhu@yeah.net; Ye, Yu-Sheng, E-mail: yeyusheng@aliyun.com; Li, Yong-Sheng, E-mail: 872868848@qq.com; Zhang, Zhi-Gong, E-mail: zzgedward@sina.com; Xie, Wen-Tao, E-mail: 345344347@qq.com [The First Affiliated Hospital of Anhui Medical University, Department of Vascular Surgery (China)

    2017-03-15

    Thoracic aortic aneurysms are now routinely repaired with endovascular repair if anatomically feasible because of advantages in safety and recovery. However, intraoperative aneurysm rupture is a severe complication which may have an adverse effect on the outcome of treatment. Comprehensive preoperative assessment and considerate treatment are keys to success of endovascular aneurysm repair, especially during unexpected circumstances. Few cases have reported on intraoperative aortic rupture, which were successfully managed by endovascular treatment. Here, we present a rare case of an intraoperative aneurysm rupture during endovascular repair of thoracic aortic aneurysm with narrow neck and angulated aorta arch (coarctation-associated aneurysm), which was successfully treated using double access route approach and iliac limbs of infrarenal devices.Level of EvidenceLevel 5.

  15. Preoperative evaluation of the abdominal aortic aneurysm using spiral CT

    International Nuclear Information System (INIS)

    Chisuwa, Hisanao; Nishimaki, Keiji; Arai, Masayuki; Honda, Haruyasu; Urata, Koichi; Miyagawa, Yusuke; Makuuchi, Masatoshi; Shimizu, Mikio; Okamoto, Kohei.

    1995-01-01

    Six patients with abdominal aortic aneurysm (AAA) were studied with three-dimensionally reconstructed CT angiography (3D-CTA) in order to evaluate its usefulness as a diagnostic tool for vascular surgery patients. Images of the intravenously contrasted abdominal aorta were obtained with spiral scan during a single breath hold. The images of the abdominal aorta and its major branches were three-dimensionally reconstructed with a shaded surface display mode. The three-dimensional image reconstruction was successful in all the six cases and performed without difficulties. Shaded surface display presented a deficit to depict the aortic wall with mural thrombus. However, multidirectional display of the abdominal aorta and its branches facilitated interpretation of the anatomical details of the lesions and planning of surgical repair. 3D-CTA is an alternative to conventional aortography for preoperative diagnosis of AAA. Moreover it was shown to be noninvasive, easy to proceed. It presented good angiographical resolution that can be used as a precise diagnostic tool in vascular surgery. (author)

  16. Is there a role for upper-extremity intra-aortic balloon counterpulsation as a bridge-to-recovery or a bridge-to-transplant in the treatment of end-stage heart failure?

    Science.gov (United States)

    Nwaejike, Nnamdi; Son, Andre Y; Milano, Carmelo A; Daneshmand, Mani A

    2017-10-01

    A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was: Is there a role for upper-extremity intra-aortic balloon pump counterpulsation (UE-IABP) in the treatment of end-stage heart failure? Altogether 230 papers were found using the reported search, of which 6 papers represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Of the 163 bridge-to-transplantation (BTT) patients, 141 (86.5%) were successfully transplanted and of the 9 bridge-to-recovery (BTR) patients, 6 (66.7%) were successfully weaned from the device. Length of support ranged from 3 to 152 days, and the most frequent complications were device malfunction or migration necessitating exchange or repositioning, occurring at a collective rate of 37.3%. UE-IABP is a minimally invasive and cost-effective strategy that provides haemodynamic support while preserving both the mediastinum and the functional status in BTR and BTT patients who may not tolerate more invasive modes of mechanical circulatory support. We conclude that UE-IABP can be used as a bridge-to-recovery (BTR) or transplant (BTT) in patients with end-stage heart failure. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  17. Feature-based US to CT registration of the aortic root

    Science.gov (United States)

    Lang, Pencilla; Chen, Elvis C. S.; Guiraudon, Gerard M.; Jones, Doug L.; Bainbridge, Daniel; Chu, Michael W.; Drangova, Maria; Hata, Noby; Jain, Ameet; Peters, Terry M.

    2011-03-01

    A feature-based registration was developed to align biplane and tracked ultrasound images of the aortic root with a preoperative CT volume. In transcatheter aortic valve replacement, a prosthetic valve is inserted into the aortic annulus via a catheter. Poor anatomical visualization of the aortic root region can result in incorrect positioning, leading to significant morbidity and mortality. Registration of pre-operative CT to transesophageal ultrasound and fluoroscopy images is a major step towards providing augmented image guidance for this procedure. The proposed registration approach uses an iterative closest point algorithm to register a surface mesh generated from CT to 3D US points reconstructed from a single biplane US acquisition, or multiple tracked US images. The use of a single simultaneous acquisition biplane image eliminates reconstruction error introduced by cardiac gating and TEE probe tracking, creating potential for real-time intra-operative registration. A simple initialization procedure is used to minimize changes to operating room workflow. The algorithm is tested on images acquired from excised porcine hearts. Results demonstrate a clinically acceptable accuracy of 2.6mm and 5mm for tracked US to CT and biplane US to CT registration respectively.

  18. Radionuclide assessment of left ventricular function in patients requiring intraoperative balloon pump assistance

    International Nuclear Information System (INIS)

    Davies, R.A.; Laks, H.; Wackers, F.J.; Berger, H.J.; Williams, B.; Hammond, G.L.; Geha, A.S.; Gottschalk, A.; Zaret, B.L.

    1982-01-01

    Twenty-three surviving patients who were weaned from cardiopulmonary bypass with intraaortic balloon pump assistance returned for follow-up radionuclide left ventricular (LV) function and thallium 201 perfusion studies at a mean of 23 +/- 3 months following operation. It was found that despite profound intraoperative myocardial depression requiring intraaortic balloon assistance, 13 patients had no change (within 10%) in the resting LV ejection fraction compared with the preoperative measurement. Among all 23 patients, there was no difference between mean (+/- standard error of the mean) preoperative and postoperative resting LV ejection fraction (48 +/- 4 vs 46 +/- 4%, p . not significant [NS]). Only 11 patients had perioperative myocardial infarction documented by new Q waves in the electrocardiogram, by elevation of creatine kinase-MB fraction, or by defects on thallium 201 imaging not explained by documented myocardial infarction before operation. Overall, postoperative resting LV ejection fraction was not different from the preoperative value in patients with perioperative myocardial infarction (44 +/- 7 vs 47 +/- 5%, p . NS). Postoperative resting LV ejection fraction rose by greater than 10% compared with preoperative values in 4 patients (3 with aortic valve replacement), remained within the 10% limit in 9 patients, and fell by greater than 10% in 10 patients (7 with perioperative myocardial infarction). Only 4 out of 16 patients studied at follow-up with exercise radionuclide studies demonstrated a normal LV response to exercise (greater than 5% increase in LV ejection fraction). Thus, among survivors requiring intraaortic balloon pump assistance for weaning from cardiopulmonary bypass, LV performance at rest is frequently preserved. In addition, 11 of the 23 patients had evidence of perioperative myocardial infarction, indicating a component of reversible intraoperative LV dysfunction

  19. Arch translocation and the intra-arch elephant-trunk technique with collared graft for extended chronic dissecting aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Ikenaga Shigeru

    2013-01-01

    Full Text Available Abstract Management of extensive, chronic, dissecting aortic aneurysms after prior repair of the ascending aorta presents a technical challenge for surgeons. A symptomatic 64-year-old patient was admitted for elective surgical repair of an aortic annular dilatation, causing severe aortic regurgitation, and a Crawford type II extended thoracoabdominal aneurysm, 4 years after he underwent primary repair of an acute aortic dissection. The aorta was diffusely dilated, and there were no sites beyond the distal aortic arch where anastomosis could be performed. We successfully performed total aortic replacement with a 2-stage strategy, using an arch translocation technique and an intra-arch elephant-trunk technique.

  20. The Effect of Preoperative Intra-Articular Methylprednisolone on Pain After TKA

    DEFF Research Database (Denmark)

    Luna, Iben E; Kehlet, Henrik; Jensen, Claus M

    2017-01-01

    In a randomized, double-blind, placebo controlled trial, we investigated the postoperative analgesic effect of a single intra-articular injection of 40 mg methylprednisolone acetate (MP) administered 1 week before total knee arthroplasty (TKA). Forty-eight patients with high pain osteoarthritis (≥5...... groups in postoperative sensitization was found (P > .4) despite reduced preoperative intra-articular inflammation (IL-6) in the MP group versus placebo (median change in IL-6 = -70 pg/mL, interquartile range = -466 to 0 vs. 32 pg/mL, interquartile range = -26 to 75, P = .029). Alternative central...

  1. Tackling the Issue of High Postoperative Pacemaker Implantation Rates in Sutureless Aortic Valve Replacement: Should Balloon Inflation be Removed from the Implantation Method of the Perceval Prosthesis?

    Science.gov (United States)

    Charles Blouin, Mathieu; Bouhout, Ismail; Demers, Philippe; Carrier, Michel; Perrault, Louis; Lamarche, Yoan; El-Hamamsy, Ismail; Bouchard, Denis

    2017-05-01

    Sutureless aortic valve replacement (AVR) is an emerging alternative to standard AVR in elderly and high-risk patients. This procedure is associated with a high rate of postoperative permanent pacemaker implantation (PPI). The study aim was to assess the impact on the rate of PPI of implanting the Perceval prosthesis without using balloon inflation. A total of 159 patients who underwent sutureless AVR using the Perceval prosthesis was included. Balloon inflation was used in 132 patients (Balloon group) and not used in the remaining 27 (No-Balloon group). Clinical, echocardiographic and electrocardiographic outcomes were assessed. There was no significant difference in PPI rate between the two groups (26% for Balloon group versus 22% in No-Balloon group; p = 0.700). Balloon inflation had no significant impact on the incidence of paravalvular leaks (p = 0.839), or on the need to return to cardiopulmonary bypass (CPB) intraoperatively due to paravalvular leak or unsatisfactory deployment (p >0.999). Mean and peak transaortic pressure gradients were similar between the two groups (p = 0.417 and p = 0.522, respectively). Cross-clamp and CPB times were shorter in the No-Balloon group (49.6 ± 15.9 min versus 61.1 ± 25.6 min and 64.1 ± 26.3 min versus 79.6 ± 35.4 min, respectively; p = 0.027 and p = 0.012, respectively). The two groups had similar postoperative PPI rates. Implanting the Perceval prosthesis without balloon inflation is safe and had no impact on paravalvular leaks, intraoperative complications or hemodynamic results. Reductions in aortic cross-clamp time and CPB time were observed when the balloon was not used.

  2. Vascular Rupture Caused by a Molding Balloon during Endovascular Aneurysm Repair: Case Report

    International Nuclear Information System (INIS)

    Lee, Hee Young; Do, Young Soo; Park, Hong Suk; Park, Kwang Bo; Kim, Young Wook; Kim, Dong Ik

    2011-01-01

    Endovascular aneurysm repair (EVAR) has been accepted as an alternative to traditional open surgery in selected patients. Despite the minimally invasiveness of this treatment, several complications may occur during or after EVAR. Complications include endoleak, aortic dissection, distal embolism, or iatrogenic injury to the access artery. However, there are few reports on the vascular rupture caused by a molding balloon during EVAR. We report two cases of infrarenal abdominal aortic aneurysms complicated by procedure-related aortic or iliac artery rupture by the molding balloon during EVAR. In our cases, we observed suddenly abrupt increase of the diameter of the endograft during balloon inflation, because we inflated the balloon rapidly. In conclusion, careful attention must be paid during inflation of the molding balloon to prevent vascular rupture.

  3. Abdominal Aortic Aneurysm (AAA)

    Science.gov (United States)

    ... Professions Site Index A-Z Abdominal Aortic Aneurysm (AAA) Abdominal aortic aneurysm (AAA) occurs when atherosclerosis or plaque buildup causes the ... weak and bulge outward like a balloon. An AAA develops slowly over time and has few noticeable ...

  4. Clinical application of preoperative embolization of tumor feeding artery combined with intraoperative balloon occlusion of the abdominal aorta in the resection of sacral tumors

    International Nuclear Information System (INIS)

    Chen Wenhua; Wang Qi; He Zhongming; Zhou Jian; Wang Yimin; Wang Jie

    2012-01-01

    Objective: To investigate the clinical application of preoperative embolization of tumor feeding artery combined with intraoperative balloon occlusion of the abdominal aorta in performing the surgical resection of sacral tumors. Methods: Conventional surgical excision of sacral tumors was employed in 24 patients with sacral tumors (control group), while preoperative embolization of tumor feeding artery combined with intraoperative balloon occlusion of the abdominal aorta was carried out in 32 patients with sacral tumors (study group). The operation time, blood loss during the surgery and the one-year recurrence rate of both groups were documented, and the results were statistically analyzed. Results: Angiography showed that in the study group the sacral tumors were supplied by several vessels, and these feeding arteries were occluded separately. The tumors were successfully removed in all patients with the help of intraoperative balloon occlusion of the abdominal aorta. During the surgery, the surgical area was clearly exposed and the blood loss wa remarkably reduced. After the surgery, no ectopic vascular embolization, renal ischemia, limb ischemia or other complications occurred. Statistically significant difference in the operation time, blood loss during the surgery and the one-year recurrence rate existed between the two groups (P<0.05). Conclusion: Preoperative embolization of tumor feeding artery combined with intraoperative balloon occlusion of the abdominal aorta can effectively shorten the operation time, reduce the blood loss during the surgery and provide a clear surgical field, and thus the surgical safety can be significantly ensured. (authors)

  5. Pre-operative Duplex Ultrasonography in Arteriovenous Fistula Creation: Intra- and Inter-observer Agreement.

    Science.gov (United States)

    Zonnebeld, Niek; Maas, Tommy M G; Huberts, Wouter; van Loon, Magda M; Delhaas, Tammo; Tordoir, Jan H M

    2017-11-01

    Although clinical guidelines on arteriovenous fistula (AVF) creation advocate minimum luminal arterial and venous diameters, assessed by duplex ultrasonography (DUS), the clinical value of routine DUS examination is under debate. DUS might be an insufficiently repeatable and/or reproducible imaging modality because of its operator dependency. The present study aimed to assess intra- and inter-observer agreement of DUS examination in support of AVF surgery planning. Ten end stage renal disease patients were included, to assess intra- and inter-observer agreement of pre-operative DUS measurements. All measurements were performed by two trained and experienced vascular technicians, blinded to measurement readings. From the routine DUS protocol, representative measurements (venous diameters, and arterial diameters and volume flow in the upper arm and forearm) were selected. For intra-observer agreement the measurements were performed in triplicate, with the probe released from the skin between each. Intraclass correlation coefficients were calculated for intra- and inter-observer agreement, and Bland-Altman plots used to graphically display mean measurement differences and limits of agreement. Ten patients (6 male, 59.4±19.7 years) consented to participate, and all predefined measurements were obtained. Intraclass correlation coefficients for intra-observer agreement of diameter measurements were at least 0.90 (95% CI 0.74-0.97; radial artery). Inter-observer agreement was at least 0.83 (0.46-0.96; lateral diameter upper arm cephalic vein). The Bland-Altman plots showed acceptable mean measurement differences and limits of agreement. In experienced hands, excellent intra- and inter-observer agreement can be reached for the discrete pre-operative DUS measurements advocated in clinical guidelines. DUS is therefore a reliable imaging modality to support AVF surgery planning. The content of DUS protocols, however, needs further standardisation. Copyright © 2017 European

  6. Avaliação da captura de fragmentos por meio da filtração intra-aórtica em pacientes submetidos à troca valvar aórtica Particulate emboli capture by an intra-aortic filter device during aortic valve replacement

    Directory of Open Access Journals (Sweden)

    Osanan Amorim Leite Filho

    2008-09-01

    Full Text Available OBJETIVO: O objetivo deste estudo foi avaliar a atividade embólica de pacientes portadores de estenose aórtica calcificada submetidos a troca valvar aórtica por meio da filtração intra-aórtica com dispositivo EMBOL-X® System (Edwards Lifesciences Inc., Mountain View, CA, USA. MÉTODOS: De janeiro de 2007 a julho de 2007, foi utilizado o filtro intra-aórtico EMBOL-X após o despinçamento aórtico em 13 portadores de estenose aórtica calcificada submetidos a troca valvar aórtica consecutivamente. A média de idade dos pacientes foi 63,7 anos (34-79 e 61,5% eram do sexo feminino. A média do tempo de CEC foi 60,2±7,5 (45-72 minutos e a média do tempo despinçamento aórtico foi 50±7,5 (35-63 minutos. Após a retirada dos filtros, eles foram fixados em formalina, analisados macroscopicamente e quantificados os fragmentos capturados. Foi realizado exame histológico do material capturado. RESULTADOS Não foi observado nenhum caso de complicação neurológica. Nenhum paciente apresentou insuficiência renal pós-operatória. Não houve óbitos hospitalares. Partículas embólicas foram encontradas em cinco (38,5% dos filtros. Das partículas embólicas capturadas, em dois (40% filtros havia fibrina, dois (40% apresentavam tecido conjuntivo, um (20% continha hemácias e em um não foi possível determinar a natureza. CONCLUSÃO: O dispositivo EMBOL-X® System foi efetivo na captação de fragmentos intra-aórticos na substituição da valva aórtica em pacientes com estenose aórtica calcificada.OBJECTIVE: This study aims to analyze the embolic activity in patients with calcified aortic stenosis who underwent aortic valve replacement using intra-aortic filtration with an EMBOL-X® System device (Edwards Lifesciences Inc., Mountain View, CA, USA. METHODS: From January 2007 to July 2007, 13 consecutive patients with calcified aortic stenosis, who underwent isolated aortic valve replacement using intra-aortic filtration by an EMBOL

  7. Aortic Regurgitation in Patients Undergoing Transcatheter Aortic Valve Replacement With the Self-Expanding CoreValve Versus the Balloon-Expandable SAPIEN XT Valve.

    Science.gov (United States)

    Kiramijyan, Sarkis; Magalhaes, Marco A; Koifman, Edward; Didier, Romain; Escarcega, Ricardo O; Baker, Nevin C; Negi, Smita I; Minha, Sa'ar; Torguson, Rebecca; Jiaxiang, Gai; Asch, Federico M; Wang, Zuyue; Okubagzi, Petros; Gaglia, Michael A; Ben-Dor, Itsik; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2016-05-01

    The incidence of aortic regurgitation (AR) after transcatheter aortic valve replacement (TAVR) in a self-expanding and a balloon-expandable system is controversial. This study aimed to examine the incidence and severity of post-TAVR AR with the CoreValve (CV) versus the Edwards XT Valve (XT). Baseline, procedural, and postprocedural inhospital outcomes were compared. The primary end point was the incidence of post-TAVR AR of any severity, assessed with a transthoracic echocardiogram, in the CV versus XT groups. A multivariate logistic regression analysis was completed to evaluate for correlates of the primary end point. The secondary end points included the change in severity of AR at 30-day and 1-year follow-up. A total of 223 consecutive patients (53% men, mean age 82 years) who had transfemoral TAVR with either a CV (n = 119) or XT (n = 104) were evaluated. The rates of post-TAVR AR in the groups were similar, and there was no evidence of more-than-moderate AR in either group. There were significant differences in the rates of intraprocedural balloon postdilation with the CV (17.1%) versus XT valve (5.8%; p = 0.009) and in the rates of intraprocedural implantation of a second valve-in-valve prosthesis with the CV (9.9%) versus XT valve (2.2%; p = 0.036). There were no significant differences in inhospital safety outcomes between the 2 groups. In conclusion, the incidence of post-TAVR AR is similar between the CV and the XT valve when performed by experienced operators using optimal intraprocedural strategies, as deemed appropriate, to mitigate the severity of AR. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Evaluation of Factors Influencing Liver Function Test in On-Pump Coronary Artery Bypass Graft Surgery

    Directory of Open Access Journals (Sweden)

    Shahrbano Shahbazi

    2013-12-01

    Full Text Available Background: Liver dysfunction during on-pump coronary artery bypass graft surgery (CABG is a rare complication but is associated with significant morbidity and mortality. The ability to identify high-risk patients may be helpful in planning appropriate management strategies. We aimed to evaluate the factors influencing liver function tests during on-pump CABG. Methods: In 146 patients scheduled for on-pump CABG, the liver function test was done preoperatively and on the first postoperative day. Some preoperative and intraoperative risk factors were checked and then the postoperative liver function tests were compared with the preoperative ones. Probable relationships between these changes and the preoperative and intraoperative risk factors were studied. Results: A medical history of diabetes had a significant relationship with the changes in direct bilirubin. Preoperative central venous pressure had a significant relationship with the changes in aspartate aminotransferase and alanine aminotransferase. Use of intra-aortic balloon pump and duration of aortic cross-clamp were significantly related to the changes in the liver function tests except for alanine aminotransferase and alkaline phosphatase. Conclusion: It seems that the techniques for the reduction of cardiopulmonary bypass and aortic cross-clamp duration may be useful to protect liver function. We recommend that a larger population of patients be studied to confirm these findings.

  9. Full-root aortic valve replacement with stentless xenograft achieves superior regression of left ventricular hypertrophy compared to pericardial stented aortic valves.

    Science.gov (United States)

    Tavakoli, Reza; Auf der Maur, Christoph; Mueller, Xavier; Schläpfer, Reinhard; Jamshidi, Peiman; Daubeuf, François; Frossard, Nelly

    2015-02-03

    Full-root aortic valve replacement with stentless xenografts has potentially superior hemodynamic performance compared to stented valves. However, a number of cardiac surgeons are reluctant to transform a classical stented aortic valve replacement into a technically more demanding full-root stentless aortic valve replacement. Here we describe our technique of full-root stentless aortic xenograft implantation and compare the early clinical and midterm hemodynamic outcomes to those after aortic valve replacement with stented valves. We retrospectively compared the pre-operative characteristics of 180 consecutive patients who underwent full-root replacement with stentless aortic xenografts with those of 80 patients undergoing aortic valve replacement with stented valves. In subgroups presenting with aortic stenosis, we further analyzed the intra-operative data, early postoperative outcomes and mid-term regression of left ventricular mass index. Patients in the stentless group were younger (62.6 ± 13 vs. 70.3 ± 11.8 years, p regression of the left ventricular mass index in the stentless (p replacement can be performed without adversely affecting the early morbidity or mortality in patients operated on for aortic valve stenosis provided that the coronary ostia are not heavily calcified. The additional time necessary for the full-root stentless compared to the classical stented aortic valve replacement is therefore not detrimental to the early clinical outcomes and is largely rewarded in patients with aortic stenosis by lower transvalvular gradients at mid-term and a better regression of their left ventricular mass index.

  10. Comparison of preoperative computerized tomography scan imaging of temporal bone with the intra-operative findings in patients undergoing mastiodectomy

    International Nuclear Information System (INIS)

    Gerami, H.; Naghavi, E.; Wahabi-Moghadam, M.; Forghanparast, K.; Akbar, Manzar H.

    2009-01-01

    Objective was to compare the consistency rates of pre- and intra-operative radiological findings in patients with chronic suppurative otitis media (CSOM). In a cross-sectional study, 80 patients with CSOM underwent pre-operative CT scanning and we compared the results with intra-operative clinical findings during mastiodectomy from 2000-2004 in the Otology Department, Amiralmomenin Hospital of Guilan Medical University, Rasht, Iran. Sensitivity, specificity, positive and negative predictive value of CT scan in tympanic and mastoid cholesteatoma, ossicular chain erosion, tegmentympani erosion, dehiscence of facial canal, lateral semicircular canal (LSCC) fistula were assessed. Then, correlation between radiological findings and intra-operative findings were calculated. The mean age of patients was 27.9+-16.3 years. Mostly were males (n=57 [71.3%]). Correlation of preoperative radiological images with intra-operative clinical findings were moderate to good on tympanic cholesteatoma, mastoid cholesteatoma and ossicular chain erosion, but weak and insignificant in cases of tegmen erosion, facial canal dehiscene and LSCC fistulae. Preoperative CT scan may be helpful in decision-making for surgery in cases of cholesteatoma and ossicular erosion. Despite of limitations radiological scanning is a useful adjunct to management of CSOM. (author)

  11. Mucosal perforation during laparoscopic surgery for achalasia: impact of preoperative pneumatic balloon dilation.

    Science.gov (United States)

    Souma, Yoshihito; Nakajima, Kiyokazu; Taniguchi, Eiji; Takahashi, Tsuyoshi; Kurokawa, Yukinori; Yamasaki, Makoto; Miyazaki, Yasuhiro; Makino, Tomoki; Hamada, Tetsuhiro; Yasuda, Jun; Yumiba, Takeyoshi; Ohashi, Shuichi; Takiguchi, Shuji; Mori, Masaki; Doki, Yuichiro

    2017-03-01

    Controversy remains whether preoperative pneumatic balloon dilation (PBD) influences the surgical outcome of laparoscopic esophagocardiomyotomy in patients with esophageal achalasia. The aim of this study was to evaluate whether preoperative PBD represents a risk factor for surgical complications and affects the symptomatic and/or functional outcomes of laparoscopic Heller myotomy with Dor fundoplication (LHD). A retrospective chart review was conducted on a prospectively compiled surgical database of 103 consecutive patients with esophageal achalasia who underwent LHD from November 1994 to September 2014. The following data were compared between the patients with preoperative PBD (PBD group; n = 26) and without PBD (non-PBD group; n = 77): (1) patients' demographics: age, gender, body mass index, duration of symptoms, maximum transverse diameter of esophagus; (2) operative findings: operating time, blood loss, intraoperative complications; (3) postoperative course: complications, clinical symptoms, postoperative treatment; and (4) esophageal functional tests: preoperative and postoperative manometric data and postoperative profile of 24-h esophageal pH monitoring. (1) No significant differences were observed in the patients' demographics. (2) Operative findings were similar between the two groups; however, the incidence of mucosal perforation was significantly higher in the PBD group (n = 8; 30.7 %) compared to the non-PBD group (n = 6; 7.7 %) (p = 0.005). (3) Postoperative complications were not encountered in either group. The differences were not significant for postoperative clinical symptoms, the incidence of gastroesophageal reflux disease, or necessity of postoperative treatments. (4) Lower esophageal sphincter pressure was effectively reduced in both groups, and no differences were observed in manometric data or 24-h pH monitoring profiles between the two groups. Multivariate logistic regression analysis showed that preoperative PBD and the

  12. Risk Prediction in Aortic Valve Replacement: Incremental Value of the Preoperative Echocardiogram.

    Science.gov (United States)

    Tan, Timothy C; Flynn, Aidan W; Chen-Tournoux, Annabel; Rudski, Lawrence G; Mehrotra, Praveen; Nunes, Maria C; Rincon, Luis M; Shahian, David M; Picard, Michael H; Afilalo, Jonathan

    2015-10-26

    Risk prediction is a critical step in patient selection for aortic valve replacement (AVR), yet existing risk scores incorporate very few echocardiographic parameters. We sought to evaluate the incremental predictive value of a complete echocardiogram to identify high-risk surgical candidates before AVR. A cohort of patients with severe aortic stenosis undergoing surgical AVR with or without coronary bypass was assembled at 2 tertiary centers. Preoperative echocardiograms were reviewed by independent observers to quantify chamber size/function and valve function. Patient databases were queried to extract clinical data. The cohort consisted of 432 patients with a mean age of 73.5 years and 38.7% females. Multivariable logistic regression revealed 3 echocardiographic predictors of in-hospital mortality or major morbidity: E/e' ratio reflective of elevated left ventricular (LV) filling pressure; myocardial performance index reflective of right ventricular (RV) dysfunction; and small LV end-diastolic cavity size. Addition of these echocardiographic parameters to the STS risk score led to an integrated discrimination improvement of 4.1% (Pvalue to the STS risk score and should be integrated in prediction when evaluating the risk of AVR. In addition, findings of small hypertrophied LV cavities and/or low mean aortic gradients confer a higher risk of 2-year mortality. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  13. A comparison of Selective Aortic Arch Perfusion and Resuscitative Endovascular Balloon Occlusion of the Aorta for the management of hemorrhage-induced traumatic cardiac arrest: A translational model in large swine.

    Directory of Open Access Journals (Sweden)

    Ed B G Barnard

    2017-07-01

    Full Text Available Survival rates remain low after hemorrhage-induced traumatic cardiac arrest (TCA. Noncompressible torso hemorrhage (NCTH is a major cause of potentially survivable trauma death. Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA at the thoracic aorta (Zone 1 can limit subdiaphragmatic blood loss and allow for IV fluid resuscitation when intrinsic cardiac activity is still present. Selective Aortic Arch Perfusion (SAAP combines thoracic aortic balloon hemorrhage control with intra-aortic oxygenated perfusion to achieve return of spontaneous circulation (ROSC when cardiac arrest has occurred.Male Yorkshire Landrace cross swine (80.0 ± 6.0 kg underwent anesthesia, instrumentation for monitoring, and splenectomy. TCA was induced by laparoscopic liver lobe resection combined with arterial catheter blood withdrawal to achieve a sustained systolic blood pressure <10 mmHg, cardiac arrest. After 3 min of arrest, swine were allocated to one of three interventions: (1 REBOA plus 4 units of IV fresh whole blood (FWB, (2 SAAP with oxygenated lactated Ringer's (LR, 1,600 mL/2 min, or (3 SAAP with oxygenated FWB 1,600 mL/2 min. Primary endpoint was survival to the end of 60 min of resuscitation, a simulated prehospital phase. Thirty animals were allocated to 3 groups (10 per group-5 protocol exclusions resulted in a total of 35 animals being used. Baseline measurements and time to cardiac arrest were not different amongst groups. ROSC was achieved in 0/10 (0%, 95% CI 0.00-30.9 REBOA, 6/10 (60%, 95% CI 26.2-87.8 SAAP-LR and 10/10 (100%, 95% CI 69.2-100.0 SAAP-FWB animals, p < 0.001. Survival to end of simulated 60-minute prehospital resuscitation was 0/10 (0%, 95% CI 0.00-30.9 for REBOA, 1/10 (10%, 95% CI 0.25-44.5 for SAAP-LR and 9/10 (90%, 95% CI 55.5-99.7 for SAAP-FWB, p < 0.001. Total FWB infusion volume was similar for REBOA (2,452 ± 0 mL and SAAP-FWB (2,250 ± 594 mL. This study was undertaken in laboratory conditions, and as such may have

  14. Perioperative management of endovascular abdominal aortic aneurysm repair

    International Nuclear Information System (INIS)

    Wang Haofu; Wang Yuwei; Li Jun; Zhao Zonggang; Qi Sen

    2010-01-01

    with prosthesis. Three cases developed type III endoleak. Balloon dilation followed by additional stent-graft placement was adopted in one case. Thoracic endovascular aortic repair with subsequent EVAR was carried out in another patient with Stanford type A aortic dissection. Re-examination with CTA was performed 7-10 days after the treatment, and once a year thereafter. Results: EVAR was successfully completed in all patients. The main complications included thrombosis due to vascular kinking (n=1) and disruption of abdominal incision (n=1). No death due to surgery occurred. During the follow-up period of 6 month to 5 years all patients remained alive. Conclusion: With the advantages of high imaging quality and usefulness for accurate measure of parameters, CTA is the gold standard for preoperative and postoperative evaluation. EVAR is a safe and effective treatment for abdominal aortic aneurysm in aged patients with high-risk. (authors)

  15. Retained intraaortic balloon. Case report and review of the literature.

    Science.gov (United States)

    Grande, A M; Martinelli, L; Graffigna, A; Viganò, M

    1995-01-01

    We report a case of intraaortic balloon entrapment in a 70-year-old man who underwent emergency triple coronary bypass. Intraaortic balloon rupture caused the formation of a clot inside the balloon that eventually was responsible for the balloon's entrapment at the aortic bifurcation. The patient had severe atherosclerosis of the aorta and iliac arteries. Balloon removal required aorto-iliac exposure and aorto-bifemoral bypass. After 16 months, he is symptom free and at home.

  16. The ultrastructure of tumor cells in patients with rectal cancer after pre-operative irradiation and intra-operative cryotherapy

    International Nuclear Information System (INIS)

    Vyinnik, Yu.O.; Kotenko, O.Je.; Nevzorov, V.P.; Chyibyisov, L.P.

    2000-01-01

    Electronic microscopy of the tumor cells was performed to confirm the efficacy of combined pre-operative gamma-therapy and intraoperative cryotherapy (CT). Pre-operative irradiation at the dose of 20 Gy accompanied by intra-operative cryotherapy caused the changes in the ultrastructure, the depth and degree of which allow to consider them destructive and irreversible

  17. The impact of arm circumference on noninvasive oscillometric blood pressure referenced with intra-aortic blood pressure.

    Science.gov (United States)

    Shangguan, Qing; Wu, Yanqing; Xu, Jinsong; Su, Hai; Li, Juxiang; Hong, Kui; Cheng, Xiaoshu

    2015-12-01

    To investigate the influence of arm circumference (AC) on the brachial blood pressure (BP) measured with an adult cuff. This study included 208 patients (150 men, 61.0±8.0 years) for coronary angiography. Intra-aortic BP and noninvasive right brachial oscillometric BP (noninvasive BP) were measured simultaneously before coronary angiography. The noninvasive BP was measured using an electronic oscillometric device with an adult cuff (12×22 cm). The mid-ACs were measured. Thus, proper cuff-arm (≤26 cm) and small cuff (>26 cm) groups were created. The difference in intra-aortic and noninvasive BP was calculated as BPi-n. The correlation coefficients (r) between noninvasive and invasive systolic blood pressure (SBP), mean artery pressure, and diastolic blood pressure (DBP) were 0.88, 0.76, and 0.58, respectively. The SBPi-n was higher (7.9±1.6 vs. 5.2±1.1 mmHg), but the DBPi-n (3.9±1.4 vs. 6.1±1.0 mmHg, P26 cm. Among the four subgroups divided by 20-23, 24-26, 27-30, and 31-37 cm of AC, as the AC increased, the SBPi-n increased, but DBP decreased, resulting in noninvasive SBP 4.6 mmHg higher and noninvasive DBP 4.6 mmHg lower in the 31-37 cm group in comparison with the 20-23 cm group. When an adult cuff was used, the noninvasive oscillometric SBP was overestimated, but DBP was underestimated in the individuals with large arms against the intra-aortic BP.

  18. Dynamics of the aortic annulus in 4D CT angiography for transcatheter aortic valve implantation patients

    NARCIS (Netherlands)

    Elattar, Mustafa A.; Vink, Leon W.; van Mourik, Martijn S.; Baan, Jan; Vanbavel, Ed T.; Planken, R. Nils; Marquering, Henk A.

    2017-01-01

    Transcatheter aortic valve implantation (TAVI) is a well-established treatment for patients with severe aortic valve stenosis. This procedure requires pre-operative planning by assessment of aortic dimensions on CT Angiography (CTA). It is well-known that the aortic root dimensions vary over the

  19. Intra-operative Vector Flow Imaging Using Ultrasound of the Ascending Aorta among 40 Patients with Normal, Stenotic and Replaced Aortic Valves

    DEFF Research Database (Denmark)

    Hansen, Kristoffer Lindskov; Møller-Sørensen, Hasse; Kjaergaard, Jesper

    2016-01-01

    Stenosis of the aortic valve gives rise to more complex blood flows with increased velocities. The angleindependent vector flow ultrasound technique transverse oscillation was employed intra-operatively on the ascending aorta of (I) 20 patients with a healthy aortic valve and 20 patients with aor...... replacement corrects some of these changes. Transverse oscillation may be useful for assessment of aortic stenosis and optimization of valve surgery. (E-mail: lindskov@gmail.com) 2016 World Federation for Ultrasound in Medicine & Biology...... with aortic stenosis before (IIa) and after (IIb) valve replacement. The results indicate that aortic stenosis increased flow complexity (p , 0.0001), induced systolic backflow (p , 0.003) and reduced systolic jet width (p , 0.0001). After valve replacement, the systolic backflow and jet width were normalized...

  20. Regression in left ventricular mass after aortic valve replacement for chronic aortic regurgitation is unrelated to prosthetic valve size.

    Science.gov (United States)

    Brown, Morgan L; Schaff, Hartzell V; Suri, Rakesh M; Li, Zhuo; Sundt, Thoralf M; Dearani, Joseph A; Enriquez-Sarano, Maurice

    2011-08-01

    We examined the role of prosthesis-patient mismatch on left ventricular mass regression after aortic valve replacement for chronic aortic valve regurgitation. We selected patients who had complete preoperative and follow-up echocardiograms with measurement of left ventricular mass. Patients were excluded who had moderate or greater aortic valve stenosis, concomitant coronary artery bypass grafting, or mitral valve procedures. Patients' mean age was 55 ± 17 years; 21% were female. The mean preoperative indexed left ventricular mass was 150 ± 45 g/m(2). Patients with mildly (n = 44; mean indexed mass, 126 ± 15 g/m(2)), moderately (n = 31; mean indexed mass, 168 ± 11 g/m(2)), or severely (n = 15; mean indexed mass, 241 ± 34 g/m(2)) increased preoperative indexed left ventricular mass, were similar, except for lower ejection fractions, larger end-diastolic dimensions, and larger ventricular wall thicknesses in the severely enlarged group (P regression was unrelated to labeled valve size, prosthesis-patient mismatch, or measured indexed effective aortic valve area. A greater preoperative indexed left ventricular mass (P regression. Despite having greater left ventricular mass regression, patients with severe preoperative indexed left ventricular mass did not return to normal values (mean, 142 ± 25 g/m(2)). Left ventricular mass regression after aortic valve replacement for chronic aortic regurgitation is unrelated to indexed prosthetic valve area. Although incomplete, regression is greatest in patients with the largest preoperative indexed left ventricular mass. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  1. Intra-aortic mural thrombosis and splenic infarction in association with ulcerative colitis.

    LENUS (Irish Health Repository)

    Kok, H K

    2010-03-04

    BACKGROUND: Arterial thrombosis is a very rare, but recognised complication of inflammatory bowel disease that can result in significant morbidity and mortality. CASE PRESENTATION: We present the case of a 48-year-old female with previously well-controlled ulcerative colitis who presented with severe left upper quadrant abdominal pain. Imaging investigations subsequently revealed a large intra-aortic mural thrombus extending into the coeliac axis complicated by splenic infarction. This occurred in the absence of other prothrombotic states such as thrombophilias or vasculitis. CONCLUSION: This case highlights the frequently overlooked association between inflammatory bowel disease and arterial thrombosis.

  2. Preoperative localization of endocrine pancreatic tumours by intra-arterial dynamic computed tomography

    International Nuclear Information System (INIS)

    Ahlstroem, H.; Magnusson, A.; Grama, D.; Eriksson, B.; Oeberg, K.; Loerelius, L.E.; Akademiska Sjukhuset, Uppsala; Akademiska Sjukhuset, Uppsala

    1990-01-01

    Eleven patients with biochemically confirmed endocrine pancreatic tumours were examined with intra-arterial (i.a.) dynamic computed tomography (CT) and angiography preoperatively. Seven of the patients suffered from the multiple endocrine neoplasia type 1 (MEN-1) syndrome. All patients were operated upon and surgical palpation and ultrasound were the peroperative localization methods. Of the 33 tumours which were found at histopathologic analysis of the resected specimens in the 11 patients, 7 tumours in 7 patients were correctly localized by both i.a. dynamic CT and angiography. Six patients with MEN-1 syndrome had multiple tumours and this group of patients together had 28 tumours, of which 5 (18%) were localized preoperatively by both CT and angiography. I.a. dynamic CT, with the technique used by us, does not seem to improve the localization of endocrine pancreatic tumours, especially in the rare group of MEN-1 patients, as compared with angiography. (orig.)

  3. [Anesthetic Management of a Patient Complicated with Marfan Syndrome and Suffering from Stanford Type A Aortic Dissection during Pregnancy].

    Science.gov (United States)

    Uozaki, Nako; Mizuno, Kaori; Shiraishi, Yoshito; Doi, Matsuyuki; Sato, Shigehito

    2015-04-01

    We report a case of a 36-year-old woman at 34 weeks of gestation complicated with Marfan syndrome who underwent Bentall type aortic replacement surgery due to Stanford type A aortic dissection after undergoing caesarean section. Since this patient exhibited severe hypotension before coming to the operating room, it was very difficult to determine whether the cardiac surgery or caesarean section should be performed first. In this case, the caesarean section was performed first, followed by Bentall's surgery. Although intra-aortic balloon pumping and percutaneous cardiopulmonary support were required after weaning from the cardiopulmonary bypass, she was discharged on post-operative day (POD) 40 and the baby was discharged on POD 60, without signs of cerebral palsy. Unfortunately, this patient died on POD 57, due to heart failure. We discuss how to determine the priority of surgeries for patients who require emergency surgery for cardiovascular disease during pregnancy.

  4. An Intra-Abdominal Desmoid Tumor, Embedded in the Pancreas, Preoperatively Diagnosed as an Extragastric Growing Gastrointestinal Stromal Tumor

    Directory of Open Access Journals (Sweden)

    Mari Mizuno

    2017-04-01

    Full Text Available A 45-year-old woman was found to have a pancreatic tumor by abdominal ultrasound performed for a medical check-up. Abdominal contrast-enhanced computed tomography showed a hypovascular tumor measuring 30 mm in diameter in the pancreatic tail. Endoscopic ultrasound-guided fine needle aspiration was performed. An extragastric growing gastrointestinal stromal tumor was thereby diagnosed preoperatively, and surgical resection was planned. Laparoscopic surgery was attempted but conversion to open surgery was necessitated by extensive adhesions, and distal pancreatectomy, splenectomy, and partial gastrectomy were performed. The histological diagnosis was an intra-abdominal desmoid tumor. A desmoid tumor is a fibrous soft tissue tumor arising in the fascia and musculoaponeurotic tissues. It usually occurs in the extremities and abdominal wall, and only rarely in the abdominal cavity. We experienced a case with an intra-abdominal desmoid tumor that was histologically diagnosed after laparotomy, which had been preoperatively diagnosed as an extragastric growing gastrointestinal stromal tumor. Although rare, desmoid tumors should be considered in the differential diagnosis of intra-abdominal tumors. Herein, we report this case with a literature review.

  5. Aortic intracardiac echocardiography-guided septal puncture during mitral valvuloplasty.

    Science.gov (United States)

    Akkaya, Emre; Vuruskan, Ertan; Zorlu, Ali; Sincer, Isa; Kucukosmanoglu, Mehmet; Ardic, Idris; Yilmaz, Mehmet Birhan

    2014-01-01

    Transoesophageal echocardiography (TEE) and venous intracardiac echocardiography (ICE) are traditionally used to visualize the interatrial septum (IAS) and the tenting effect of the fossa ovalis in patients undergoing percutaneous balloon mitral valvuloplasty (PBMV). The aim of the present study was to assess the comparative efficacy and safety of arterial (intra-aortic) ICE and venous ICE, compared with TEE (traditional approach), in the patients undergoing PBMV. TEE, aortic ICE, and venous ICE were consecutively performed in 50 patients (40 ± 9 years, 86% female). The images of intracardiac structures were obtained from both aortic and right atrial loci. The IAS was visualized using TEE, aortic ICE, and venous ICE. The mean mitral valve area was 1.14 ± 0.2 cm(2), and the mean left atrial volume index was 57.5 ± 12 mL/m(2). The mean size of the visualized septal length was 48 ± 5 mm by TEE, 51 ± 5 mm by aortic ICE, and 33 ± 6 mm by venous ICE. The Bland-Altman test indicated that the 95% limits of agreement for the measurement of septal diameter ranged from -11.0 to +5.9 mm (mean -2.5 mm) between TEE and aortic ICE, -2.8 to +33.5 mm (mean +15.3 mm) between TEE and venous ICE, and -36.6 to +0.8 mm (mean -17.9 mm) between venous and aortic ICE. Standard venous ICE generally tended to yield smaller values compared with TEE and aortic ICE for the measurement of septal length. Furthermore, the view of fossa ovalis and 'tenting effect' was optimal in 11 patients on venous ICE; however, the fossa ovalis and tip of the needle were well visualized in all patients on aortic ICE (P < 0.001). There were no major complications with the use of aortic ICE. Aortic ICE is a superior alternative to venous ICE and facilitates trans-septal puncture in patients with mitral stenosis.

  6. Evaluation of intra-aortic CT angiography performances for the visualisation of spinal vascular malformations' angioarchitecture

    International Nuclear Information System (INIS)

    Clarencon, Frederic; Gabrieli, Joseph; Chiras, Jacques; Di Maria, Federico; Sourour, Nader-Antoine; Shotar, Eimad; Cormier, Evelyne; Fahed, Robert; Nouet, Aurelien; Cornu, Philippe

    2016-01-01

    To evaluate the performances of the CT-angiography by direct intra-aortic contrast media injection (IA-CTA) for spinal vascular malformations (SVMs)' imaging. Thirteen patients (8 males, 5 females, mean age: 56 y) with suspected SVM underwent IA-CTAs by direct intra-aortic iodinated contrast media injection (5 cc/s; 100 cc) via an arterial femoral or humeral access. Two independent observers evaluated the angioarchitecture of the SVMs and the visualisation of both the Adamkiewicz artery and the anterior spinal artery. Then a consensus was obtained between the 2 reviewers; the results of the IA-CTA were finally compared with those of the full spinal DSA evaluated in consensus. The IA-CTA was feasible in all cases and depicted the SVM in all except one case (92 %). Interrater agreement was good for the location of the SVMs' level. Intermodality (IA-CTA/DSA) agreement was excellent for the level and side of the shunt point, as well as for the SVM subtype evaluation. In 77 % of the cases, the Adamkiewicz artery was satisfactorily seen at the same time on IA-CTA. IA-CTA is a new technique that seems helpful to reach a better understanding of SMVs and may help to tailor more precisely their treatment. (orig.)

  7. Preoperative balloon occluded arterial infusion chemotherapy for locally invasive bladder cancer. Accurate staging for bladder preservation

    International Nuclear Information System (INIS)

    Hayashi, Norio; Arima, Kiminobu; Kawamura, Juichi; Tochigi, Hiromi

    1999-01-01

    The possibility of bladder preservation by preoperative balloon occluded arterial infusion (BOAI) chemotherapy was studied in 111 patients with locally invasive bladder cancer. BOAI was performed by blocking the blood flow of the internal iliac artery and by performing intra-arterial infusion of adriamycin (50 mg/body) and cisplatin (100 mg/body). Before BOAI the clinical diagnosis was T2 in 36, T3a in 29, T3b in 27, T4 in 11 and after BOAI it was T0 in 1, T1 in 27, T2 in 25, T3a in 20, T3b in 20, and T4 in 10. Down staging was observed on diagnostic images in 46.6%. Thirty patients (27.0%) received transurethral resection of bladder tumor (TUR-Bt) and their bladder could be preserved. The 5-year cancer-specific survival rate was 100% in pT0 (n=9), 97.5% in pT1 (n=47), 79.9% in pT2 (n=21), 80.0% in pT3a (n=6), 39.9% in pT3b (n=18) and 51.9% in pT4 cases (n=9). For the bladder preservation, accurate staging diagnosis is required. Since 1992, endorectal magnetic resonance imaging (MRI) has been used in addition to imaging diagnosis for improving the accuracy of staging diagnosis. The accuracies of staging diagnosis with and without endorectal MRI were 62.5% and 44.0%, respectively. BOAI as a neoadjuvant chemotherapy has the possibility of bladder-preserving therapy in locally invasive bladder cancer. Also, the endorectal MRI can improve the accuracy of staging diagnosis, which is important for the bladder preservation. (author)

  8. Valve-sparing aortic root replacement†

    NARCIS (Netherlands)

    Koolbergen, David R.; Manshanden, Johan S. J.; Bouma, Berto J.; Blom, Nico A.; Mulder, Barbara J. M.; de Mol, Bas A. J. M.; Hazekamp, Mark G.

    2015-01-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed.

  9. Significant intra-valvular pressure loss across EPIC SUPRA and perimount magna supra-annular designed aortic bioprostheses in patients with normal aortic size

    Directory of Open Access Journals (Sweden)

    Jagdish C. Mohan

    2017-01-01

    Full Text Available Doppler-derived trans-prosthetic gradients are higher and the estimated effective valve area is smaller than the catheter-derived and directly measured hemodynamic values, mostly due to pressure recovery phenomenon. Pressure recovery to a varying extent is common to all prosthetic heart valves including bioprostheses. Pressure recovery-related differences are usually small except in patients with bileaflet metallic prosthesis, wherein high-pressure local jets across central orifice have been documented since long back and also in patients with narrow aortic root. We describe two patients with normally functioning stented aortic bioprostheses with supra-annular design (EPIC SUPRA and PERIMOUNT MAGNA, wherein very high trans-prosthetic gradients and critically reduced estimated effective valve orifice areas in presence of normal aortic size were consistently recorded over long periods of follow-up. The valve leaflets, however had normal excursion, were thin, opened with a triangular or oblong shape and had expected geometric valve area (1.7 and 1.6 cm2 respectively measured by 3D trans-oesophageal echocardiographic planimetry. Pressure recovery upstream the valves accounted for 20% and 12% of total pressure gradients respectively. Dominant site for pressure drop was intra-valvular (75–85%. Such a phenomenon has not been reported in vivo for these two valve designs.

  10. Significant intra-valvular pressure loss across EPIC SUPRA and perimount magna supra-annular designed aortic bioprostheses in patients with normal aortic size.

    Science.gov (United States)

    Mohan, Jagdish C; Mohan, Vishwas; Shukla, Madhu; Sethi, Arvind

    Doppler-derived trans-prosthetic gradients are higher and the estimated effective valve area is smaller than the catheter-derived and directly measured hemodynamic values, mostly due to pressure recovery phenomenon. Pressure recovery to a varying extent is common to all prosthetic heart valves including bioprostheses. Pressure recovery-related differences are usually small except in patients with bileaflet metallic prosthesis, wherein high-pressure local jets across central orifice have been documented since long back and also in patients with narrow aortic root. We describe two patients with normally functioning stented aortic bioprostheses with supra-annular design (EPIC SUPRA and PERIMOUNT MAGNA), wherein very high trans-prosthetic gradients and critically reduced estimated effective valve orifice areas in presence of normal aortic size were consistently recorded over long periods of follow-up. The valve leaflets, however had normal excursion, were thin, opened with a triangular or oblong shape and had expected geometric valve area (1.7 and 1.6cm 2 respectively) measured by 3D trans-oesophageal echocardiographic planimetry. Pressure recovery upstream the valves accounted for 20% and 12% of total pressure gradients respectively. Dominant site for pressure drop was intra-valvular (75-85%). Such a phenomenon has not been reported in vivo for these two valve designs. Copyright © 2016. Published by Elsevier B.V.

  11. Evaluation of intra-aortic CT angiography performances for the visualisation of spinal vascular malformations' angioarchitecture

    Energy Technology Data Exchange (ETDEWEB)

    Clarencon, Frederic; Gabrieli, Joseph; Chiras, Jacques [Pitie-Salpetriere Hospital, Department of Interventional Neuroradiology, Paris (France); Paris VI University, Pierre et Marie Curie University, Paris (France); Di Maria, Federico; Sourour, Nader-Antoine; Shotar, Eimad; Cormier, Evelyne; Fahed, Robert [Pitie-Salpetriere Hospital, Department of Interventional Neuroradiology, Paris (France); Nouet, Aurelien [Pitie-Salpetriere Hospital, Department of Neurosurgery, Paris (France); Cornu, Philippe [Paris VI University, Pierre et Marie Curie University, Paris (France); Pitie-Salpetriere Hospital, Department of Neurosurgery, Paris (France)

    2016-10-15

    To evaluate the performances of the CT-angiography by direct intra-aortic contrast media injection (IA-CTA) for spinal vascular malformations (SVMs)' imaging. Thirteen patients (8 males, 5 females, mean age: 56 y) with suspected SVM underwent IA-CTAs by direct intra-aortic iodinated contrast media injection (5 cc/s; 100 cc) via an arterial femoral or humeral access. Two independent observers evaluated the angioarchitecture of the SVMs and the visualisation of both the Adamkiewicz artery and the anterior spinal artery. Then a consensus was obtained between the 2 reviewers; the results of the IA-CTA were finally compared with those of the full spinal DSA evaluated in consensus. The IA-CTA was feasible in all cases and depicted the SVM in all except one case (92 %). Interrater agreement was good for the location of the SVMs' level. Intermodality (IA-CTA/DSA) agreement was excellent for the level and side of the shunt point, as well as for the SVM subtype evaluation. In 77 % of the cases, the Adamkiewicz artery was satisfactorily seen at the same time on IA-CTA. IA-CTA is a new technique that seems helpful to reach a better understanding of SMVs and may help to tailor more precisely their treatment. (orig.)

  12. Mechanisms of recurrent aortic regurgitation after aortic valve repair: predictive value of intraoperative transesophageal echocardiography.

    Science.gov (United States)

    le Polain de Waroux, Jean-Benoît; Pouleur, Anne-Catherine; Robert, Annie; Pasquet, Agnès; Gerber, Bernhard L; Noirhomme, Philippe; El Khoury, Gébrine; Vanoverschelde, Jean-Louis J

    2009-08-01

    The aim of the present study was to examine the intraoperative echocardiographic features associated with recurrent severe aortic regurgitation (AR) after an aortic valve repair surgery. Surgical valve repair for AR has significant advantages over valve replacement, but little is known about the predictors and mechanisms of its failure. We blindly reviewed all clinical, pre-operative, intraoperative, and follow-up transesophageal echocardiographic data of 186 consecutive patients who underwent valve repair for AR during a 10-year period and in whom intraoperative and follow-up echo data were available. After a median follow-up duration of 18 months, 41 patients had recurrent 3+ AR, 23 patients presented with residual 1+ to 2+ AR, and 122 had no or trivial AR. In patients with recurrent 3+ AR, the cause of recurrent AR was the rupture of a pericardial patch in 3 patients, a residual cusp prolapse in 26 patients, a restrictive cusp motion in 9 patients, an aortic dissection in 2 patients, and an infective endocarditis in 1 patient. Pre-operatively, all 3 groups were similar for aortic root dimensions and prevalence of bicuspid valve (overall 37%). Patients with recurrent AR were more likely to display Marfan syndrome or type 3 dysfunction pre-operatively. At the opposite end, patients with continent AR repair at follow-up were more likely to have type 2 dysfunction pre-operatively. After cardiopulmonary bypass, a shorter coaptation length, the degree of cusp billowing, a lower level of coaptation (relative to the annulus), a larger diameter of the aortic annulus and the sino-tubular junction, the presence of a residual AR, and the width of its vena contracta were associated with the presence of AR at follow-up. Multivariate Cox analysis identified a shorter coaptation length (odds ratio [OR]: 0.8, p = 0.05), a coaptation occurring below the level of the aortic annulus (OR: 7.9, p < 0.01), a larger aortic annulus (OR: 1.2, p = 0.01), and residual aortic regurgitation

  13. Repeat transcatheter aortic valve implantation using a latest generation balloon-expandable device for treatment of failing transcatheter heart valves.

    Science.gov (United States)

    Schaefer, Andreas; Treede, Hendrik; Seiffert, Moritz; Deuschl, Florian; Schofer, Niklas; Schneeberger, Yvonne; Blankenberg, Stefan; Reichenspurner, Hermann; Schaefer, Ulrich; Conradi, Lenard

    2016-01-15

    Paravalvular leakage (PVL) is a known complication of transcatheter aortic valve implantation (TAVI) and is associated with poor outcome. Besides balloon-post-dilatation, valve-in-valve (ViV) procedures can be taken into consideration to control this complication. Herein we present initial experience with use of the latest generation balloon-expandable Edwards Sapien 3® (S3) transcatheter heart valve (THV) for treatment of failing THVs. Between 01/2014 and 12/2014 three patients (two male, age: 71-80 y, log EUROScore I: 11.89 - 32.63) with failing THVs were refered to our institution for further treatment. THV approach with secondary implantation of an S3 was chosen after mutual agreement of the local interdisciplinary heart team at an interval of 533-1119 days from the index procedure. The performed procedures consisted of: S3 in Sapien XT, JenaValve and CoreValve. Successful transfemoral implantation with significant reduction of PVL was achieved in all cases. No intraprocedural complications occurred regarding placement of the S3 with a postprocedural effective orifice area (EOA) of 1.5-2.5 cm(2) and pressure gradients of max/mean 14/6-36/16 mmHg. 30-day mortality was 0%. At the latest follow-up of 90-530 days, all patients are alive and well with satisfactory THV function. Regarding VARC-2 criteria one major bleeding and one TIA was reported. In the instance of moderate or severe aortic regurgitation after TAVI, S3 ViV deployment is an excellent option to reduce residual regurgitation to none or mild. For further assertions concerning functional outcomes long-term results have to be awaited.

  14. Factors Affecting Optimal Aortic Remodeling After Thoracic Endovascular Aortic Repair of Type B (IIIb) Aortic Dissection

    Energy Technology Data Exchange (ETDEWEB)

    Chen, I-Ming [National Yang Ming University, Institute of Clinical Medicine, School of Medicine (China); Chen, Po-Lin; Huang, Chun-Yang [National Yang Ming University, Department of Medicine, School of Medicine (China); Weng, Shih-Hsien; Chen, Wei-Yuan; Shih, Chun-Che, E-mail: ccshih@vghtpe.gov.tw [National Yang Ming University, Institute of Clinical Medicine, School of Medicine (China)

    2017-05-15

    PurposeThe purpose of this study was to determine factors associated with entire aortic remodeling after thoracic endovascular aortic repair (TEVAR) in patients with type B dissection.Materials and MethodsThe patients with type B (IIIb) dissections who underwent TEVAR from 2006 to 2013 with minimum of 2 years of follow-up computed tomography data were retrospectively reviewed. Based on the status of false lumen remodeling of entire aorta, patients were divided into three groups: complete regression, total thrombosis, and inadequate regression with patent abdominal false lumen.ResultsA total of 90 patients (72 males, 18 females; mean age 56.6 ± 16.4 years) were included and divided into the complete regression (n = 22), total thrombosis (n = 18), and inadequate regression (n = 50) groups. Multivariate logistic regression analysis indicated that dissection extension to iliac arteries, increased preoperative number of dissection tear over abdominal aorta, and decreased preoperative abdominal aorta bifurcation true lumen ratio, as compared between the inadequate and complete regression groups, were associated with a persistent false lumen (odds ratio = 33.33, 2.304, and 0.021; all, p ≤ 0.012). Comparison of 6, 12, and 24 months postoperative data revealed no significant differences at any level, suggesting that the true lumen area ratio might not change after 6 months postoperatively.ConclusionsIncreased preoperative numbers of dissection tear around the abdominal visceral branches, dissection extension to the iliac arteries, and decreased preoperative true lumen area ratio of abdominal aorta are predictive of entire aortic remodeling after TEVAR in patients with type B dissection.Level of EvidenceIII.

  15. Factors Affecting Optimal Aortic Remodeling After Thoracic Endovascular Aortic Repair of Type B (IIIb) Aortic Dissection

    International Nuclear Information System (INIS)

    Chen, I-Ming; Chen, Po-Lin; Huang, Chun-Yang; Weng, Shih-Hsien; Chen, Wei-Yuan; Shih, Chun-Che

    2017-01-01

    PurposeThe purpose of this study was to determine factors associated with entire aortic remodeling after thoracic endovascular aortic repair (TEVAR) in patients with type B dissection.Materials and MethodsThe patients with type B (IIIb) dissections who underwent TEVAR from 2006 to 2013 with minimum of 2 years of follow-up computed tomography data were retrospectively reviewed. Based on the status of false lumen remodeling of entire aorta, patients were divided into three groups: complete regression, total thrombosis, and inadequate regression with patent abdominal false lumen.ResultsA total of 90 patients (72 males, 18 females; mean age 56.6 ± 16.4 years) were included and divided into the complete regression (n = 22), total thrombosis (n = 18), and inadequate regression (n = 50) groups. Multivariate logistic regression analysis indicated that dissection extension to iliac arteries, increased preoperative number of dissection tear over abdominal aorta, and decreased preoperative abdominal aorta bifurcation true lumen ratio, as compared between the inadequate and complete regression groups, were associated with a persistent false lumen (odds ratio = 33.33, 2.304, and 0.021; all, p ≤ 0.012). Comparison of 6, 12, and 24 months postoperative data revealed no significant differences at any level, suggesting that the true lumen area ratio might not change after 6 months postoperatively.ConclusionsIncreased preoperative numbers of dissection tear around the abdominal visceral branches, dissection extension to the iliac arteries, and decreased preoperative true lumen area ratio of abdominal aorta are predictive of entire aortic remodeling after TEVAR in patients with type B dissection.Level of EvidenceIII.

  16. Impact of Aortic Insufficiency on Ascending Aortic Dilatation and Adverse Aortic Events After Isolated Aortic Valve Replacement in Patients With a Bicuspid Aortic Valve.

    Science.gov (United States)

    Wang, Yongshi; Wu, Boting; Li, Jun; Dong, Lili; Wang, Chunsheng; Shu, Xianhong

    2016-05-01

    Aberrant flow pattern and congenital fragility bestows bicuspid aortic valve (BAV) with a propensity toward ascending aorta dilatation, aneurysm, and dissection. Whether isolated aortic valve replacement (AVR) can prevent further dilatation in BAV ascending aorta and what indicates concurrent aortic intervention in the case of valve operation remain controversial. From June 2006 to January 2009, patients with a BAV who underwent isolated AVR were consecutively included and categorized into aortic insufficiency (BAV-AI, n = 84) and aortic stenosis (n = 112) groups, and another population of patients with a tricuspid aortic valve with aortic insufficiency (n = 149) was also recruited during the same period for comparison of annual aortic dilatation rate and adverse aortic events after isolated AVR. With a median follow-up period of 72 months (interquartile range, 66 to 78 months), ascending aorta dilatation rates were faster in the BAV-AI group than the BAV plus aortic stenosis and tricuspid aortic valve with aortic insufficiency groups (both p regression analysis identified aortic insufficiency (hazard ratio, 3.7; 95% confidence interval, 1.2 to 11.1; p = 0.019) as an independent risk factor for adverse aortic events among patients with BAV in general, whereas preoperative ascending aortic diameter larger than 45 mm (hazard ratio, 13.8; 95% confidence interval, 3.0 to 63.3; p = 0.001) served as a prognostic indicator in the BAV-AI group. An aggressive policy of preventive aortic interventions seemed appropriate in patients with BAV-AI during AVR, and BAV phenotype presenting as either insufficiency or stenosis should be taken into consideration when contemplating optimal surgical strategies for BAV aortopathy. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  17. How to perform combined cutting balloon and high pressure balloon valvuloplasty for dogs with subaortic stenosis.

    Science.gov (United States)

    Kleman, Mandi E; Estrada, Amara H; Maisenbacher, Herbert W; Prošek, Robert; Pogue, Brandon; Shih, Andre; Paolillo, Joseph A

    2012-01-01

    Subvalvular aortic stenosis (SAS) is one of the most common congenital cardiac malformations in dogs. Unfortunately, the long term success rate and survival data following either open heart surgery or catheter based intervention has been disappointing in dogs with severe subaortic stenosis. Medical therapy is currently the only standard recommended treatment option. A cutting balloon dilation catheter has been used successfully for resistant coronary artery and peripheral pulmonary arterial stenoses in humans. This catheter is unique in that it has the ability to cut, or score, the stenotic region prior to balloon dilatation of the stenosis. The use of cutting balloon valvuloplasty combined with high pressure valvuloplasty for dogs with severe subaortic stenosis has recently been reported to be a safe and feasible alternative therapeutic option. The following report describes this technique, outlines the materials required, and provides some 'tips' for successful percutaneous subaortic balloon valvuloplasty. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Rise and fall of NT-proBNP in aortic valve intervention.

    Science.gov (United States)

    Hultkvist, Henrik; Holm, Jonas; Svedjeholm, Rolf; Vánky, Farkas

    2018-01-01

    To describe the dynamics of N-terminal pro-B-type natriuretic peptide (NT-proBNP) from preoperative evaluation to 6-month follow-up in patients undergoing aortic valve intervention, and to evaluate NT-proBNP with regard to 1-year mortality. At preoperative evaluation, we prospectively included 462 patients accepted for aortic valve intervention. The median time to surgical aortic valve replacement (SAVR; n=336) or transcatheter aortic valve implantation (TAVI; n=126) was 4 months. NT-proBNP was measured at enrolment for preoperative evaluation, on the day of surgery, postoperatively on day 1, day 3 and at the 6-month follow-up. Subgroups of patients undergoing SAVR with aortic regurgitation and aortic stenosis with and without coronary artery bypass were also analysed. NT-proBNP remained stable in all subgroups during the preoperative waiting period, but displayed a substantial transient early postoperative increase with a peak on day 3 except in the TAVI group, which peaked on day 1. At the 6-month follow-up, NT-proBNP had decreased to or below the preoperative level in all groups. In the SAVR group, NT-proBNP preoperatively and on postoperative days 1 and 3 revealed significant discriminatory power with regard to 1-year mortality (area under the curve (AUC)=0.79, P=0.0001; AUC=0.71, P=0.03; and AUC=0.79, P=0.002, respectively). This was not found in the TAVI group, which had higher levels of NT-proBNP both preoperatively and at the 6-month follow-up compared with the SAVR group. The dynamic profile of NT-proBNP differed between patients undergoing TAVI and SAVR. NT-proBNP in the perioperative course was associated with increased risk of 1-year mortality in SAVR but not in TAVI.

  19. [Application of temporary balloon blocking technique in bone tumors surgery under the aid of CT angiography].

    Science.gov (United States)

    Fang, Cheng; Hu, Yongcheng; Huang, Hongchao; Xia, Qun; Chen, Xiaopeng; Yuan, Binbin; He, Xin; Wang, Peng

    2014-10-01

    To study the value of CT angiography (CTA) in the surgical treatment of bone tumors with the temporary balloon blocking technique. A retrospective analysis was made on the clinical data of 36 bone tumor patients between April 2008 and October 2013. There were 22 males and 14 females, aged from 25 to 83 years (mean, 46 years). The tumor located at the sacrococcygeal region in 17 cases, at the ilium in 12 cases, at the pubis in 5 cases, and at the proximal femur in 2 cases. Before surgery, CTA was performed to measure the external diameter of aortaventralis and arteria iliac communis, and the distance between the low renal artery and the abdominal aortic bifurcation as well as mark the anatomical relationship between the low renal artery, the abdominal aortic bifurcation and bony landmarks of vertebral body. According to these data, suitable balloon was chosen and the balloon positioning was guided in the surgery to completely excise tumor assisted by balloon blocking technique. The CTA results showed that the external diameter of aortaventralis and arteria iliaca communis was (1.545 ± 0.248) cm and (1.060 ± 0.205) cm respectively, and the distance between the low renal artery and the abdominal aortic bifurcation was (10.818 ± 1.165) cm. The three-dimensional reconstruction showed that the opening of the low renal artery was mainly located at L1 (16/36, 44.4%) and the abdominal aortic bifurcation mainly located at L4 (22/36, 61.1%). Effective block of abdomial aorta was performed; the blood pressure obviously increased in 3 cases after balloon inflation, and pulse of the left dorsal artery of the foot decreased in 1 case after removal of balloon, which were relieved after expectant treatment. The operation time was 118-311 minutes; the intraoperative blood loss was 200-1800 mL, 21 patients were given blood transfusion, and the amount of blood transfusion was 400-1200 mL; and the aortic clamping time was 40-136 minutes. All patients were followed up 5-44 months

  20. A Novel Minimally Invasive Reduction Technique by Balloon and Distractor for Intra-Articular Calcaneal Fractures: A Report of 2 Cases

    Directory of Open Access Journals (Sweden)

    M. Prod’homme

    2018-01-01

    Full Text Available Treatment of displaced intra-articular fractures of the calcaneus remains a challenge for the orthopaedic surgeon. Conservative therapy is known to produce functional impairment. Surgical approach is plagued by soft-tissue complications and insufficient fracture reduction. We describe a minimally invasive technique that will hopefully improve these issues. We want to present our first experience through two cases. The first was a 46-year-old man who presented with a Sanders type IIBC calcaneal fracture, and the second was a 86-year-old woman with a type IIIBC calcaneal fracture. We introduced 2 Schanz screws in the talus and the calcaneus. After distraction, we introduced an inflatable balloon inside the calcaneus. By inflating the balloon, the articular surface was reduced by lifting it up. Then bone cement was injected in order to maintain the reduction. Additional screw fixation was used in the young patient. Postoperative imaging showed good congruence of the subtalar joint without leakage of cement, for the two cases. After 2 months, the patients had no pain and were without soft-tissue complications. We advocate this technique to perform a minimally invasive reduction and fixation of intra-articular calcaneal fractures because it preserves soft-tissues and provides good clinical results with early weight-bearing.

  1. Clinical application of preoperative endovascular management for jugular paraganglioma

    International Nuclear Information System (INIS)

    Yu Juming; Fan Guoping; Zhong Weixing; Zhang Yongping; Peng Haiteng; Cheng Yongde

    2009-01-01

    Objective: To investigate the clinical value of preoperative angiography and embolization managements for jugular paraganglioma. Methods: Fourteen patients with jugular paraganglioma were carefully evaluated with CT, MRI and clinical ENT exams. Bilateral carotid and affected-side vertebral angiography together with embolization of the feeding arteries and tumor nidi were performed in all 14 patients before surgery. Internal carotid artery balloon occlusive test was employed to check the function of Willis' circle in 7 patients. The tumors were excised within 48 hours after embolization. Results: Preoperative angiographic and embolization procedures of jugular paraganglioma were successfully accomplished in all patients. The mean blood loss during the surgery was obviously less than usual. Of seven cases who passed the internal carotid artery balloon occlusive test,carotid artery ligation was adopted in 3. No new symptoms and signs of nervous system developed after the surgery and during the follow-up period. Conclusion: The angiography and embolization of feeding-arteries and tumor nidi, and the preoperative balloon occlusive test of carotid artery performed before the surgery of jugular paraganglioma are safe and reliable, which can be regarded as a routine preoperative preparation. (authors)

  2. Factors associated with the development of aortic valve regurgitation over time after two different techniques of valve-sparing aortic root surgery.

    Science.gov (United States)

    Hanke, Thorsten; Charitos, Efstratios I; Stierle, Ulrich; Robinson, Derek; Gorski, Armin; Sievers, Hans-H; Misfeld, Martin

    2009-02-01

    Early results after aortic valve-sparing root reconstruction are excellent. Longer-term follow-up, especially with regard to aortic valve function, is required for further judgment of these techniques. Between July of 1993 and September of 2006, 108 consecutive patients (mean age 53.0 +/- 15.8 years) underwent the Yacoub operation (group Y) and 83 patients underwent the David operation (group D). Innovative multilevel hierarchic modeling methods were used to analyze aortic regurgitation over time. In general, aortic regurgitation increased with time in both groups. Factors associated with the development of a significant increase in aortic regurgitation were Marfan syndrome, concomitant cusp intervention, and preoperative aortic anulus dimension. In Marfan syndrome, the initial aortic regurgitation was higher in group Y versus group D (0.56 aortic regurgitation vs 0.29 aortic regurgitation, P = .049), whereas the mean annual progression rate of aortic regurgitation was marginally higher in group Y (0.132 aortic regurgitation vs 0.075 aortic regurgitation, P = .1). Concomitant cusp intervention was associated with a significant aortic regurgitation increase in both groups (P Marfan syndrome and a large preoperative aortic annulus diameter were better treated with the reimplantation technique, whereas those with a smaller diameter were better treated with the remodeling technique. Concomitant free-edge plication of prolapsing cusps was disadvantageous in both groups. Considering these factors may serve to improve the aortic valve longevity after valve-sparing aortic root surgery.

  3. Effect of preoperative oral S-1 combined with regional intra-arterial chemotherapy on malignant molecule expression in locally advanced unresectable gastric cancer tissue

    Directory of Open Access Journals (Sweden)

    Lei Liu

    2016-11-01

    Full Text Available Objective: To study the effect of preoperative oral S-1 combined with regional intra-arterial chemotherapy on malignant molecule expression in locally advanced unresectable gastric cancer tissue. Methods: A total of 144 patients with locally advanced gastric cancer receiving surgical resection after neoadjuvant chemotherapy in our hospital between May 2012 and August 2015 were selected and randomly divided into experimental group who received preoperative oral S-1 combined with regional intra-arterial chemotherapy and control group who received preoperative intravenous systemic chemotherapy. The levels of serum tumor markers were determined after chemotherapy, and the expression levels of tumor suppressor genes and cell cycle-related molecules in tumor tissue were determined after surgical resection. Results: After neoadjuvant chemotherapy, the serum G-17, TK-1, CEA, CA19-9, CA12-5, CA72-4 and CK, CK-MB, ALT, AST levels of experimental group were significantly lower than those of control group; after surgical resection, the p16, p27, PTEN and TXNIP mRNA levels in tumor tissue of experimental group were significantly higher than those of control group while CyclinB2, CyclinD1, CyclinE, CDK1 and CDK2 mRNA levels were significantly lower than those of control group. Conclusions: Preoperative oral S-1 combined with regional intra-arterial chemotherapy can more effectively kill gastric cancer cells, reduce tumor load, inhibit cell cycle and promote cell apoptosis.

  4. Quantified degree of eccentricity of aortic valve calcification predicts risk of paravalvular regurgitation and response to balloon post-dilation after self-expandable transcatheter aortic valve replacement.

    Science.gov (United States)

    Park, Jun-Bean; Hwang, In-Chang; Lee, Whal; Han, Jung-Kyu; Kim, Chi-Hoon; Lee, Seung-Pyo; Yang, Han-Mo; Park, Eun-Ah; Kim, Hyung-Kwan; Chiam, Paul T L; Kim, Yong-Jin; Koo, Bon-Kwon; Sohn, Dae-Won; Ahn, Hyuk; Kang, Joon-Won; Park, Seung-Jung; Kim, Hyo-Soo

    2018-05-15

    Limited data exist regarding the impact of aortic valve calcification (AVC) eccentricity on the risk of paravalvular regurgitation (PVR) and response to balloon post-dilation (BPD) after transcatheter aortic valve replacement (TAVR). We investigated the prognostic value of AVC eccentricity in predicting the risk of PVR and response to BPD in patients undergoing TAVR. We analyzed 85 patients with severe aortic stenosis who underwent self-expandable TAVR (43 women; 77.2±7.1years). AVC was quantified as the total amount of calcification (total AVC load) and as the eccentricity of calcium (EoC) using calcium volume scoring with contrast computed tomography angiography (CTA). The EoC was defined as the maximum absolute difference in calcium volume scores between 2 adjacent sectors (bi-partition method) or between sectors based on leaflets (leaflet-based method). Total AVC load and bi-partition EoC, but not leaflet-based EoC, were significant predictors for the occurrence of ≥moderate PVR, and bi-partition EoC had a better predictive value than total AVC load (area under the curve [AUC]=0.863 versus 0.760, p for difference=0.006). In multivariate analysis, bi-partition EoC was an independent predictor for the risk of ≥moderate PVR regardless of perimeter oversizing index. The greater bi-partition EoC was the only significant parameter to predict poor response to BPD (AUC=0.775, p=0.004). Pre-procedural assessment of AVC eccentricity using CTA as "bi-partition EoC" provides useful predictive information on the risk of significant PVR and response to BPD in patients undergoing TAVR with self-expandable valves. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Aortic rupture during aortoplasty in Takayasu arteritis – A rare complication: Case report and review of literature

    Directory of Open Access Journals (Sweden)

    Vimal Mehta

    2014-05-01

    Full Text Available Balloon angioplasty of the stenosed aorta is usually a relatively simple, yet potentially a catastrophic procedure. Aortic rupture during aortoplasty, though uncommon, carries a high mortality. We report case of a 39-year-old female with aortoarteritis with multiple arterial stenoses whose infra-renal abdominal aorta ruptured during balloon dilatation of the stent deployed in that segment. The site of aortic rupture was temporarily occluded by low-pressure inflation of the same balloon and then was sealed using a stent-graft introduced by contra-lateral femoral arterial access.

  6. Valsartan attenuates intimal hyperplasia in balloon-injured rat aortic arteries through modulating the angiotensin-converting enzyme 2-angiotensin-(1-7)-Mas receptor axis.

    Science.gov (United States)

    Li, Yonghong; Cai, Shanglang; Wang, Qixin; Zhou, Jingwei; Hou, Bo; Yu, Haichu; Ge, Zhiming; Guan, Renyan; Liu, Xu

    2016-05-15

    The role of the Mas receptor in the activity of valsartan against intimal hyperplasia is unclear. Herein, we investigated the role of the angiotensin-converting enzyme 2 (ACE2)-angiotensin-(1-7)-Mas receptor axis on the activity of valsartan against intimal hyperplasiain balloon-injured rat aortic arteries. Wistar rats were randomized equally into the sham control group, injured group, and injured plus valsartan (20 mg/kg/d)-treated group. Valsartan significantly attenuated the vascular smooth muscle cell proliferation and intimal and medial thickening on days 14 and 28 after injury. The angiotensin-(1-7) levels as well as ACE2 and Mas receptor mRNA/protein expression were significantly decreased in the injured rats, compared to the uninjured rats; meanwhile, the angiotensin II level as well as the ACE and AT1 receptor mRNA/protein expression were increased (all P valsartan significantly increased the angiotensin-(1-7) levels as well as ACE2 and Mas receptor mRNA/protein expression but decreased the angiotensin II level, ACE and AT1 receptor mRNA/protein expression, as well as the p-ERK protein expression, compared to the injured group (all P valsartan attenuates neointimal hyperplasiain balloon-injured rat aortic arteries through activation of the ACE2-angiotensin-(1-7)-Mas axis as well as inhibition of the ACE-angiotensin II-AT1 and p-ERK pathways. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. The adventitia layer modulates the arterial wall elastic response to intra-aortic counterpulsation: in vivo studies.

    Science.gov (United States)

    Cabrera-Fischer, Edmundo I; Bia, Daniel; Zócalo, Yanina; Wray, Sandra; Armentano, Ricardo

    2013-12-01

    There is a relationship between the intra-aortic balloon pumping (IABP) benefits and the dynamic behavior of muscular arteries, which is associated with induced changes on the vessel walls through an endothelial-dependent mechanism. The arterial wall elastic behavior is influenced by adventitial function; however, no studies were performed in order to elucidate if this layer plays a role in the changes determined by IABP. Our aim was to quantify acute IABP effects on the mechanical properties of muscular arteries in induced acute heart failure (AHF), before and after adventitia removal. Pressure and diameter were recorded in the iliac arteries (IA) of sheep (n = 7), before and during 1:2 IABP: (i) in control state (CS) with intact IA, (ii) in CS after IA adventitia removal, and (iii) in de-adventitialized IA after AHF. Conduit function, compliance and arterial distensibility were calculated in each state. During CS, IABP resulted in intact IA dilatation and in an increase in conduit function, compliance and distensibility; adventitial removal determined an increase of arterial stiffness with respect to the CS, which decreased when IABP was used; the increase in arterial stiffness observed after adventitia removal was also detected in AHF state; IABP improves conduit function and arterial stiffness in de-adventitialized arteries, both before and during AHF. However, the improvement in these properties was lower than in intact arteries. Before and after AHF induction, the improvements of conduit function and arterial distensibility determined by IABP in intact IA were significantly reduced after adventitia removal. Adventitial layer integrity would be necessary to maximize IABP-related beneficial effects on arterial system properties. © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

  8. Primary Intra-aortic Epstein-Barr Virus-Positive Large B-Cell Lymphoma Presenting as Aortic Mural Thrombosis: An Entity Distinct From Intravascular Large B-Cell Lymphoma.

    Science.gov (United States)

    Nakao, Ryuta; Sakashita, Aki; Omoto, Atsushi; Sato, Osamu; Hino, Yoko; Yanagisawa, Akio; Urata, Yoji

    2017-12-01

    Intravascular selective growth of neoplastic B lymphocytes is a characteristic finding of intravascular large B-cell lymphoma (IVLBCL). However, because neoplastic B cells of IVLBCL grow merely in the lumina of capillaries or small vessels, primary IVLBCL of the great vessels is considered exceptional. To our knowledge, only 2 primary B-cell lymphomas in the lumina of the vena cava have been reported. However, there has been no report of primary B-cell lymphoma with intra-aortic growth. We describe a novel manifestation of primary Epstein-Barr virus-positive large B-cell lymphoma mainly affecting the lumina of the aorta and its major branches in a 76-year-old man. He had a long-term fever that was refractory to antibiotics and aortic mural thrombosis with visceral embolization. Because he had no detectable mass suggesting a malignancy, it was difficult to diagnose while he was alive. He died without anticancer treatment, and the confirmed diagnosis was made at autopsy.

  9. Effect of personalized external aortic root support on aortic root motion and distension in Marfan syndrome patients.

    Science.gov (United States)

    Izgi, Cemil; Nyktari, Evangelia; Alpendurada, Francisco; Bruengger, Annina Studer; Pepper, John; Treasure, Tom; Mohiaddin, Raad

    2015-10-15

    Personalized external aortic root support (PEARS) is a novel surgical approach with the aim of stabilizing the aortic root size and decreasing risk of dissection in Marfan syndrome patients. A bespoke polymer mesh tailored to each patient's individual aorta shape is produced by modeling and then surgically implanted. The aim of this study is to assess the mechanical effects of PEARS on the aortic root systolic downward motion (an important determinant of aortic wall stress), aortic root distension and on the left ventricle (LV). A cohort of 27 Marfan patients had a prophylactic PEARS surgery between 2004 and 2012 with 24 having preoperative and follow-up cardiovascular magnetic resonance imaging studies. Systolic downward aortic root motion, aortic root distension, LV volumes/mass and mitral annular systolic excursion before the operation and in the latest follow-up were measured randomly and blinded. After a median follow-up of 50.5 (IQR 25.5-72) months following implantation of PEARS, systolic downward motion of aortic root was significantly decreased (12.6±3.6mm pre-operation vs 7.9±2.9mm latest follow-up, p<0.00001). There was a tendency for a decrease in systolic aortic root distension but this was not significant (median 4.5% vs 2%, p=0.35). There was no significant change in LV volumes, ejection fraction, mass and mitral annular systolic excursion in follow-up. PEARS surgery decreases systolic downward aortic root motion which is an important determinant of longitudinal aortic wall stress. Aortic wall distension and Windkessel function are not significantly impaired in the follow-up after implantation of the mesh which is also supported by the lack of deterioration of LV volumes or mass. Crown Copyright © 2015. Published by Elsevier Ireland Ltd. All rights reserved.

  10. An unusual case of aortic rupture after deployment of a bare stent in the treatment of aortic dissection in a patient with giant-cell arteritis.

    Science.gov (United States)

    Rynio, Pawel; Kazimierczak, Arkadiusz; Gutowski, Piotr; Cnotliwy, Miloslaw

    2017-06-01

    Giant-cell arteritis is associated with a higher risk of aortic aneurysm and aortic dissection formation. We present a women with aortic dissection type B treated with a stent graft and bare-metal stent implantation. After the stent deployment we noticed aortic rupture, which was successfully treated with implantation of an additional stent graft. This report highlights the difficulty of endovascular therapy in patients with giant-cell arteritis. We have to bear in mind that chronic inflammation of the aorta leads to a more fragile aortic wall than normal. We recommend the use of a stent graft over a bare-metal stent and gentle use of a balloon catheter.

  11. Bowel perforation due to break and distal passage of the safety ring of an adjustable intra-gastric balloon: A potentially life threatening situation.

    Science.gov (United States)

    Al-Zubaidi, Ali M; Alghamdi, Hassan U; Alzobydi, Abdu H; Dhiloon, Irshad A; Qureshi, Laeeque A

    2015-04-16

    A 45-year-old man of Middle Eastern origin, morbid obese, with a body mass index of 39 had an intra-gastric balloon, filled with 500 mL of saline/methylene blue and intended as definite therapy, inserted some 8 wk previously. He was admitted to the emergency department with abdominal cramps. An ultrasound of the abdomen was performed in ER which confirmed the balloon to be in place without any abnormality. He was discharged home on symptomatic medication. Patient remains symptomatic therefore he reported back to ER 2 d later. Computed tomography scan was performed this time for further evaluation which revealed a metallic ring present in the small bowel while the intra-gastric balloon was in its proper position. There was no clinical or radiological sign of intestinal obstruction. Patient was hospitalized for observation and conservative management. The following night, patient experienced sudden and severe abdominal pain, therefore an X-ray of the abdomen in erect position was done, which showed free air under the right dome of diaphragm. Patient was transferred to O.R for emergency laparotomy. There were two small perforations identified at the site of the metallic ring entrapment. The ring was removed and the perforations were repaired. Due to increasing prevalence of obesity and advances in modalities for its management, physicians should be aware of treatment options, their benefits, complications and clinical presentation of the known complications. Physicians need to be updated to approach these complications within time, to avoid life-threatening situations caused by these appliances.

  12. Aortic valve replacement with 17-mm St. Jude Medical prostheses for a small aortic root in elderly patients.

    Science.gov (United States)

    Takaseya, Tohru; Kawara, Takemi; Tokunaga, Shigehiko; Kohno, Michitaka; Oishi, Yasuhisa; Morita, Shigeki

    2007-06-01

    There are few reports about the optimal prosthesis for elderly patients who have small aortic roots with an aortic annular size of less than 19 mm. From October 2004 to October 2006, 11 women aged 70 years or older (mean age, 74.9 +/- 3.5 years) underwent aortic valve replacement with a 17-mm Regent prosthesis (St. Jude Medical, St. Paul, MN), with the size determined using the manufacturer's sizer. Clinical status and the results of preoperative and postoperative echocardiography were evaluated. The patients had a mean body surface area of 1.33 +/- 0.13 m2. Preoperative average New York Heart Association (NYHA) functional class was 2.5 +/- 0.7. Preoperative echocardiography showed a mean indexed effective orifice area of 0.33 +/- 0.14 cm2/m2 and a left ventricular mass index of 175 +/- 63 g/m2. Seven patients underwent associated procedures. Postoperative ventilation time was 14 +/- 5.6 hours, and the intensive care unit stay was 1.0 +/- 0.4 days. No patients died perioperatively. The NYHA functional class improved to class I in 9 patients. No obstruction of valve opening was observed. A significant increase in the mean indexed effective orifice area (0.87 +/- 0.10 cm2/m2) and regression of left ventricular mass index were found (114 +/- 46 cm2/m2) on postoperative echocardiography. Aortic valve replacement in elderly patients with small aortic roots (less than 19 mm) using a 17-mm Regent prosthesis showed satisfactory clinical and hemodynamic results.

  13. Postoperative Reverse Remodeling and Symptomatic Improvement in Normal-Flow Low-Gradient Aortic Stenosis After Aortic Valve Replacement

    DEFF Research Database (Denmark)

    Carter-Storch, Rasmus; Møller, Jacob E; Christensen, Nicolaj L

    2017-01-01

    BACKGROUND: Severe aortic stenosis (AS) most often presents with reduced aortic valve area (benefit of aortic valve...... replacement (AVR) among NFLG patients is controversial. We compared the impact of NFLG condition on preoperative left ventricular (LV) remodeling and myocardial fibrosis and postoperative remodeling and symptomatic benefit. METHODS AND RESULTS: Eighty-seven consecutive patients with reduced aortic valve area...... and normal stroke volume index undergoing AVR underwent echocardiography, magnetic resonance imaging, a 6-minute walk test, and measurement of natriuretic peptides before and 1 year after AVR. Myocardial fibrosis was assessed from magnetic resonance imaging. Patients were stratified as NFLG or normal...

  14. Apical ballooning syndrome complicated by acute severe mitral regurgitation with left ventricular outflow obstruction – Case report

    Directory of Open Access Journals (Sweden)

    Celermajer David S

    2007-02-01

    Full Text Available Abstract Background Apical ballooning syndrome (or Takotsubo cardiomyopathy is a syndrome of transient left ventricular apical ballooning. Although first described in Japanese patients, it is now well reported in the Caucasian population. The syndrome mimicks an acute myocardial infarction but is characterised by the absence of obstructive coronary disease. We describe a serious and poorly understood complication of Takotsubo cardiomyopathy. Case Presentation We present the case of a 65 year-old lady referred to us from a rural hospital where she was treated with thrombolytic therapy for a presumed acute anterior myocardial infarction. Four hours after thrombolysis she developed acute pulmonary oedema and a new systolic murmur. It was presumed she had acute mitral regurgitation secondary to a ruptured papillary muscle, ischaemic dysfunction or an acute ventricular septal defect. Echocardiogram revealed severe mitral regurgitation, left ventricular apical ballooning, and systolic anterior motion of the mitral valve with significant left ventricular outflow tract gradient (60–70 mmHg. Coronary angiography revealed no obstructive coronary lesions. She had an intra-aortic balloon pump inserted with no improvement in her parlous haemodynamic state. We elected to replace her mitral valve to correct the outflow tract gradient and mitral regurgitation. Intra-operatively the mitral valve was mildly myxomatous but there were no structural abnormalities. She had a mechanical mitral valve replacement with a 29 mm St Jude valve. Post-operatively, her left ventricular outflow obstruction resolved and ventricular function returned to normal over the subsequent 10 days. She recovered well. Conclusion This case represents a serious and poorly understood association of Takotsubo cardiomyopathy with acute pulmonary oedema, severe mitral regurgitaton and systolic anterior motion of the mitral valve with significant left ventricular outflow tract obstruction. The

  15. Balloon catheter disruption of thrombus in conjunction with thrombolysis for the treatment of acute middle cerebral artery occlusion

    International Nuclear Information System (INIS)

    Liu Zhensheng; Wang Wei; Zhang Xinjiang; Fu Changbiao; Zhou Longjiang

    2009-01-01

    Objective: To assess the feasibility, safety, and efficacy of balloon disruption of thrombus by using a deflated balloon catheter combined with intra-arterial thrombolysis for the treatment of acute middle cerebral artery (MCA) occlusion. Methods: Five consecutive patients with acute MCA occlusion underwent balloon disruption combined with intra-arterial thrombolysis. The microballoon was inflated in the distal carotid artery and then deflated and advanced just distal to the occlusion site in the MCA. Thereafter, intra- arterial thrombolysis of the MCA was applied and the maximum dosage of urokinase was 500,000 U. Results: Complete recanalization was achieved in 3 patients and partial recanalization in 2. All patients got favourable clinical outcome. There was no major intracerebral hemorrhage. Conclusion: The penetration of the MCA with a deflated balloon catheter combined with an intra-arterial thrombolysis may be a safe and effective treatment for acute ischemic stroke. (authors)

  16. Five-Year Outcomes of the First Pivotal Clinical Trial of Balloon-Expandable Transcatheter Aortic Valve Replacement in Japan (PREVAIL JAPAN).

    Science.gov (United States)

    Sawa, Yoshiki; Takayama, Morimasa; Goto, Tsuyoshi; Takanashi, Shuichiro; Komiya, Tatsuhiko; Tobaru, Tetsuya; Maeda, Koichi; Kuratani, Toru; Sakata, Yasushi

    2017-07-25

    Transcatheter aortic valve replacement (TAVR) has been an alternative less invasive therapy for high-surgical risk/inoperable patients with aortic valve stenosis (AS) in Japan. We report 5-year outcomes of the first pivotal clinical trial of TAVR in Japan (PREVAIL JAPAN).Methods and Results:A total of 64 patients with AS who were considered unsuitable candidates for surgery were enrolled at 3 centers in Japan (mean age: 84.3±6.1 years, female: 65.6%, STS score: 9.0±4.5%). Transfemoral approach (TF) and transapical approach (TA) was performed in 37 patients and 27 patients, respectively. At 5 years, freedom from all-cause death was 52.7% (TF: 51.3%, TA: 56.3%). Risk of all stroke at 5-year was 15.8% (TF: 8.9%, TA: 25.5%) and risk of major adverse cardiac and cerebrovascular events at 5 years was 58.0% (TF: 51.3%, TA: 69.2%). Mild or greater aortic regurgitation (AR) at 1 week was not associated with increased all-cause death at 5 years (69.1%) compared with none or trace AR (48.3%) (P=0.184). Patients with high STS score (>8) had higher mortality rate than those with low STS scores (≤8). The 5-year data from PREVAIL JAPAN show the clinical benefit of TAVR and suggest that balloon-expandable TAVR is an effective treatment option for Japanese patients with severe AS who are not suitable for surgery. (Funded by Edwards Lifesciences Limited; ClinicalTrials.gov number, NCT01113983.).

  17. Interventions for preoperative smoking cessation

    DEFF Research Database (Denmark)

    Møller, A; Villebro, N

    2005-01-01

    Smokers have a substantially increased risk of intra- and postoperative complications. Preoperative smoking intervention may be effective in decreasing this incidence. The preoperative period may be a well chosen time to offer smoking cessation interventions due to increased patient motivation....

  18. Fate of remnant sinuses of Valsalva in patients with bicuspid and trileaflet valves undergoing aortic valve, ascending aorta, and aortic arch replacement.

    Science.gov (United States)

    Milewski, Rita Karianna; Habertheuer, Andreas; Bavaria, Joseph E; Siki, Mary; Szeto, Wilson Y; Krause, Eric; Korutla, Varun; Desai, Nimesh D; Vallabhajosyula, Prashanth

    2017-08-01

    In patients presenting with aortic valvulopathy with concomitant ascending aortic aneurysm, surgical management of the sinus of Valsalva segment remains undefined, especially for moderately dilated aortic roots. In patients with this pathology undergoing aortic valve replacement with supracoronary ascending aorta replacement, we assessed the fate of the remnant preserved sinus of Valsalva segment stratified by aortic valve morphology and pathology. From 2002 to 2015, 428 patients underwent elective aortic valve replacement with supracoronary ascending aorta replacement. Patients were stratified on the basis of valvular morphology (bicuspid aortic valve [n = 254] and tricuspid aortic valve [n = 174]), valvular pathology (bicuspid aortic valve with aortic stenosis [n = 178], bicuspid aortic valve with aortic insufficiency [n = 76], tricuspid aortic valve with aortic stenosis [n = 61], tricuspid aortic valve with aortic insufficiency [n = 113]), and preoperative sinus of Valsalva dimensions (45 mm). Kaplan-Meier analysis revealed no significant difference in freedom from reoperation in tricuspid aortic valve versus bicuspid aortic valve (P = .576). Multivariable Cox regression model performed with sinus of Valsalva dimensions at baseline and follow-up as time-varying covariates did not adversely affect survival. A repeated-measure, mixed-effects model constructed to assess longitudinal sinus of Valsalva trends revealed that the retained sinus of Valsalva dimensions remain stable over long-term follow-up (discharge to ≥10 years), irrespective of valvular morphology/pathology (bicuspid aortic valve with aortic insufficiency, tricuspid aortic valve with aortic insufficiency, tricuspid aortic valve with aortic stenosis) and preoperative sinus of Valsalva groups (45 mm). In patients with nonaneurysmal sinuses of Valsalva undergoing aortic valve replacement with supracoronary ascending aorta replacement, the sinus segment can be preserved irrespective of

  19. Comparison of intra-aortic computed tomography angiography to conventional angiography in the presurgical visualization of the Adamkiewicz artery: first results in patients with thoracoabdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Clarencon, Frederic; Maria, Federico di; Cormier, Evelyne; Sourour, Nader; Gabrieli, Joseph; Iosif, Christina; Chiras, Jacques; Gaudric, Julien; Koskas, Fabien; Jenny, Catherine

    2013-01-01

    The aim of this study was to compare the sensitivity of intra-aortic computed tomography angiography (IA-CTA) to that of regular spinal digital subtraction angiography for the presurgical location of the Adamkiewicz artery (AKA). Thirty patients (21 males, 9 females; mean age 64 years) had an IA-CTA for the location of the AKA before surgery of aneurysm (n = 24) or dissection (n = 6) of the thoracoabdominal aorta. After femoral artery puncture, a pigtail catheter was positioned at the origin of the descending aorta. CT acquisition was performed with an intra-aortic iodinated contrast media injection (15 mL/s, 120 mL). The visualization of the AKA and the location of the feeder(s) to the AKA were independently evaluated by two observers. Interrater agreement was calculated using a kappa test. Spinal angiogram by selective catheterization was systematically performed to confirm the results of the IA-CTA. The AKA was visualized by the IA-CTA in 27/30 cases (90 %); in 26/31 (84 %) cases, the continuity with the aorta was satisfactorily seen. Interrater agreement was good for the visualization of the AKA and its feeder(s): 0.625 and 0.87, respectively. In 75 % of the cases for which the AKA was visualized, the selective catheterization confirmed the results of the IA-CTA. In the remaining 25 % of the cases, the selective catheterization could not be performed due to marked vessels' tortuosity or ostium stenosis. IA-CTA is a feasible technique in a daily practice that presents a good sensitivity for the location of the AKA. (orig.)

  20. Aorto-aortic intrathoracic bypass in surgical treatment of aortic

    International Nuclear Information System (INIS)

    Gutierrez Perez, F.; Duran Reyes, A.; Bigalli, D.; Filgueira Berobide, J.

    1998-01-01

    The prevalence of coarctation of the aorta is 6.5 percent of all congenital heart defects, according to national and international data. There is a restenosis rate of patients after surgery. Factors that influence this evolution depends on the age at which patients underwent surgery for the first time the anatomy of the aortic arch and type of surgical technique. Several procedures can be used to correct the coarctation, which include surgery and balloon catheter dilation. We present here a case of a patient of 22 years old, with a recurrent coarctation of the aorta studied by echocardiography and magnetic resonance imaging. The patient underwent surgery a third time. We used an anterior approach (median sternotomy) and performed an aortic bypass graft, intrathoracic, under cardiopulmonary bypass. Evolved favorably and was discharged on the sixth day of post operative day (Author) [es

  1. A new noninvasive controlled intra-articular ankle distraction technique on a cadaver model.

    Science.gov (United States)

    Aydin, Ahmet T; Ozcanli, Haluk; Soyuncu, Yetkin; Dabak, Tayyar K

    2006-08-01

    Effective joint distraction is crucial in arthroscopic ankle surgery. We describe an effective and controlled intra-articular ankle distraction technique that we have studied by means of a fresh-frozen cadaver model. Using a kyphoplasty balloon, which is currently used in spine surgery, we tried to achieve a controlled distraction. After the fixation of the cadaver model, standard anteromedial and anterolateral portals were used for ankle arthroscopy. From the same portals, the kyphoplasty balloon was inserted and placed in an appropriate position intra-articularly. The necessary amount of distraction was achieved by inflating the kyphoplasty balloon with a pressure regulation pump. All anatomic sites of the ankle joint were easily visualized with the arthroscope during surgery by changing the pressure and the intra-articular position of the kyphoplasty balloon. Ankle distraction was clearly seen on the arthroscopic and image intensifier view. The kyphoplasty balloon is simple to place through the standard portals and the advantage is that it allows easy manipulation of the arthroscopic instruments from the same portal.

  2. Left ventricular mass regression after porcine versus bovine aortic valve replacement: a randomized comparison.

    Science.gov (United States)

    Suri, Rakesh M; Zehr, Kenton J; Sundt, Thoralf M; Dearani, Joseph A; Daly, Richard C; Oh, Jae K; Schaff, Hartzell V

    2009-10-01

    It is unclear whether small differences in transprosthetic gradient between porcine and bovine biologic aortic valves translate into improved regression of left ventricular (LV) hypertrophy after aortic valve replacement. We investigated transprosthetic gradient, aortic valve orifice area, and LV mass in patients randomized to aortic valve replacement with either the Medtronic Mosaic (MM) porcine or an Edwards Perimount (EP) bovine pericardial bioprosthesis. One hundred fifty-two patients with aortic valve disease were randomly assigned to receive either the MM (n = 76) or an EP prosthesis. There were 89 men (59%), and the mean age was 76 years. Echocardiograms from preoperative, postoperative, predismissal, and 1-year time points were analyzed. Baseline characteristics and preoperative echocardiograms were similar between the two groups. The median implant size was 23 mm for both. There were no early deaths, and 10 patients (7%) died after dismissal. One hundred seven of 137 patients (78%) had a 1-year echocardiogram, and none required aortic valve reoperation. The mean aortic valve gradient at dismissal was 19.4 mm Hg (MM) versus13.5 mm Hg (EP; p regression of LV mass index (MM, -32.4 g/m(2) versus EP, -27.0 g/m(2); p = 0.40). Greater preoperative LV mass index was the sole independent predictor of greater LV mass regression after surgery (p regression of LV mass during the first year after aortic valve replacement.

  3. [Aortic valve-sparing root reconstruction in Marfan syndrome].

    Science.gov (United States)

    Ogino, H; Sasaki, H; Hanafusa, Y; Hirata, M; Numata, S; Ando, M; Yagihara, T; Kitamura, S

    2002-07-01

    The outcome of aortic valve-sparing root reconstruction in Marfan syndrome was reviewed. Thirteen patients with Marfan syndrome underwent aortic valve-sparing root reconstruction for annuloaortic ectasia or aortic root dissection between 1994 and 1999. The grade of preoperative aortic regurgitation was I in 4, II in 2, III in 5, IV in 2 patients. The procedures of aortic valve-sparing were reimplantation in 7 and remodeling in 5 patients. There was no hospital and late death. Recurrence of aortic regurgitation greater than moderate grade developed in 1 patient immediately after the surgery and in the other 4 patients in the late stage. One patient of them required aortic valve replacement for it. Aortic valve-sparing root reconstruction is applicable in Marfan patients, although the indication should be cautious. Close observation is needed for recurrence of aortic regurgitation.

  4. Neonatal aortic stenosis.

    Science.gov (United States)

    Drury, Nigel E; Veldtman, Gruschen R; Benson, Lee N

    2005-09-01

    Neonatal aortic stenosis is a complex and heterogeneous condition, defined as left ventricular outflow tract obstruction at valvular level, presenting and often requiring treatment in the first month of life. Initial presentation may be catastrophic, necessitating hemodynamic, respiratory and metabolic resuscitation. Subsequent management is focused on maintaining systemic blood flow, either via a univentricular Norwood palliation or a biventricular route, in which the effective aortic valve area is increased by balloon dilation or surgical valvotomy. In infants with aortic annular hypoplasia but adequately sized left ventricle, the Ross-Konno procedure is also an attractive option. Outcomes after biventricular management have improved in recent years as a consequence of better patient selection, perioperative management and advances in catheter technology. Exciting new developments are likely to significantly modify the natural history of this disorder, including fetal intervention for the salvage of the hypoplastic left ventricle; 3D echocardiography providing better definition of valve morphology and aiding patient selection for a surgical or catheter-based intervention; and new transcutaneous approaches, such as duel beam echo, to perforate the valve.

  5. Chimney Technique in Supra-Aortic Branch Reconstruction in China: A Systematic and Critical Review of Chinese Published Experience.

    Science.gov (United States)

    Zhao, Yang; Shi, Yawei; Wang, Mian; Cui, Jin; Chen, Yitian; Zheng, Liang; Yin, Henghui; Chang, Guangqi

    2017-08-01

    The chimney graft (CG) technique has been proposed as a complete endovascular supra-aortic branch reconstruction for aortic pathologies. Due to the rapid growth of thoracic endovascular aortic repair (TEVAR) in China, we aimed to investigate the current data of the CG technique in this most populous country. Studies of supra-aortic branch reconstruction using the CG technique from Chinese centers were collected and analyzed. A total of 294 patients from Chinese centers who underwent TEVAR with CGs were included. There were 301 CGs performed, with a technical successful rate of 97.7%. The rate of early type I endoleaks was 7.1%, and the patency rate of the CGs was desirable. Balloon-expandable bare CGs were significantly associated with good early outcomes and a low rate of endoleaks. Current data from China revealed positive outcomes using CGs for supra-aortic branch reconstruction. Balloon-expandable bare CGs may be the first choice according to the data available but should be considered with caution.

  6. The effects of intra-articular tranexamic acid given intraoperatively and intravenous tranexamic acid given preoperatively on post surgical bleeding and transfusion rate post total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Aryo N. Triyudanto

    2017-01-01

    Full Text Available Background: Despite the advances in the design and fixation of implants in total knee replacement (TKR. the amount of postoperative bleeding is still an important issue that has not been resolved. This study aimed to measure the effectiveness of various tranexamic acid administration.Methods: This was a randomized controlled trial study, held from August 2014 to February 2016 at Cipto Mangunkusumo Hospital, Jakarta. Twenty two patients having TKR were divided into three groups: the control group, the tranexamic acid intra-articular-intraoperative group, and the intravenous preoperative group. Intraoperative bleeding, haemoglobin (Hb level on preoperative to five-day-post-surgery, total drain production, total blood tranfusion needed and the drain removal timing were recorded and compared. Numerical data were analyzed by using parametric and non-parametric test, depended on the normality of the data.Results: The amount of blood transfusion needed in both the intra-articular group (200±SD 100 mL and the intravenous group (238±SD 53 mL were significantly different compared to those in the control group (1,016±SD 308.2 mL (p=0.001. Meanwhile, there was no significant difference between the amount of blood transfusion needed in the intra-articular group and the intravenous group. Total drain production in the intra-articular group (328±SD 193 mL and intravenous group (391±SD 185 mL was significantly different compared to the control group (652±SD 150 mL (p=0.003. No significant difference between the levels of both preoperative and postoperative haemoglobin, the amount of intraoperative bleeding, and the duration of drain usage.Conclusion: Intravenous and intra-articular tranexamic acid effectively decreased transfusion volume and drain production in patients undergoing TKR.

  7. MMP-2 Isoforms in Aortic Tissue and Serum of Patients with Ascending Aortic Aneurysms and Aortic Root Aneurysms

    Science.gov (United States)

    Tscheuschler, Anke; Meffert, Philipp; Beyersdorf, Friedhelm; Heilmann, Claudia; Kocher, Nadja; Uffelmann, Xenia; Discher, Philipp; Siepe, Matthias; Kari, Fabian A.

    2016-01-01

    Objective The need for biological markers of aortic wall stress and risk of rupture or dissection of ascending aortic aneurysms is obvious. To date, wall stress cannot be related to a certain biological marker. We analyzed aortic tissue and serum for the presence of different MMP-2 isoforms to find a connection between serum and tissue MMP-2 and to evaluate the potential of different MMP-2 isoforms as markers of high wall stress. Methods Serum and aortic tissue from n = 24 patients and serum from n = 19 healthy controls was analyzed by ELISA and gelatin zymography. 24 patients had ascending aortic aneurysms, 10 of them also had aortic root aneurysms. Three patients had normally functioning valves, 12 had regurgitation alone, eight had regurgitation and stenosis and one had only stenosis. Patients had bicuspid and tricuspid aortic valves (9/15). Serum samples were taken preoperatively, and the aortic wall specimen collected during surgical aortic repair. Results Pro-MMP-2 was identified in all serum and tissue samples. Pro-MMP-2 was detected in all tissue and serum samples from patients with ascending aortic/aortic root aneurysms, irrespective of valve morphology or other clinical parameters and in serum from healthy controls. We also identified active MMP-2 in all tissue samples from patients with ascending aortic/aortic root aneurysms. None of the analyzed serum samples revealed signals relatable to active MMP-2. No correlation between aortic tissue total MMP-2 or tissue pro-MMP-2 or tissue active MMP-2 and serum MMP-2 was found and tissue MMP-2/pro-MMP-2/active MMP-2 did not correlate with aortic diameter. This evidence shows that pro-MMP-2 is the predominant MMP-2 species in serum of patients and healthy individuals and in aneurysmatic aortic tissue, irrespective of aortic valve configuration. Active MMP-2 species are either not released into systemic circulation or not detectable in serum. There is no reliable connection between aortic tissue—and serum MMP-2

  8. Study on the change of gastrointestinal hormones and Th1/Th2 indexes of patients with gastric cancer during the perioperative period

    Directory of Open Access Journals (Sweden)

    Yu-Jie Liu

    2016-01-01

    Full Text Available Objective: To investigate the effect of intra-aortic balloon counterpulsation combined with percutaneous coronary intervention (PCI in the prognosis of acute myocardial infarction patients complicated with cardiogenic shock. Methods: A total of 78 cases of acute myocardial infarction patients complicated with cardiogenic shock were enrolled for study and randomly divided into two groups, observation group received intra-aortic balloon counterpulsation combined with PCI therapy and control group received PCI therapy. Then heart function, nerve function, kidney function and humoral indicators of two groups were compared. Results: (1 target organ function: 3 d after treatment, serum CK-MB, cTnT, cTnI, NSE, VILIP1 and NMDA-R contents as well as urinary albumin / creatinine ratio, 24 h urinary microalbumin content, LVESD and LVEDD of observation group were lower than those of control group, LVEF and glomerular filtration rate were higher than those of control group; (2 humoral indicators: 6, 12, 24 and 48 h after treatment, serum NT-proBNP and PCT contents of both groups showed decreasing trend and serum NT-proBNP and PCT contents of observation group were lower than those of control group. Conclusions: Intra-aortic balloon counterpulsation combined with PCI can improve the prognosis of acute myocardial infarction patients complicated with cardiogenic shock, specifically manifested as protecting target organ function, reducing cardiac stress and relieving inflammation.

  9. Direct transcatheter aortic valve implantation with self-expandable bioprosthesis: Feasibility and safety

    Energy Technology Data Exchange (ETDEWEB)

    Fiorina, Claudia, E-mail: clafiorina@yahoo.it [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Maffeo, Diego; Curello, Salvatore [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Lipartiti, Felicia [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Chizzola, Giuliano [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); D' Aloia, Antonio [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Adamo, Marianna [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Mastropierro, Rosy [Division of Cardiothoracic Anestesiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Gavazzi, Emanuele [Department of Radiology, University of Brescia, Spedali Civili, Brescia (Italy); Ciccarese, Camilla; Chiari, Ermanna [Division of Cardiology, Cardiothoracic Department, Spedali Civili, Brescia (Italy); Ettori, Federica [Cardiac Catheterization Laboratory, Cardiothoracic Department, Spedali Civili, Brescia (Italy)

    2014-06-15

    Background: Balloon valvuloplasty has been considered a mandatory step of the transcatheter aortic valve implantation (TAVI), although it is not without risk. The aim of this work was to evaluate the feasibility and safety of TAVI performed without pre-dilation (direct TAVI) of the stenosed aortic valve. Material and Methods: Between June 2012 and June 2013, 55 consecutive TAVI performed without pre-dilation at our institution using the self-expandable CoreValve prosthesis (Medtronic, Minneapolis, MN) were analyzed and compared with 45 pre-dilated TAVI performed the previous year. Inclusion criteria were a symptomatic and severe aortic stenosis. Exclusion criteria were defined as presence of pure aortic regurgitation, degenerated surgical bioprosthesis or bicuspid aortic valve and prior procedure of balloon aortic valvuloplasty performed as a bridge to TAVI. Results: High-burden calcification in the device landing zone, assessed by CT scan, was found in most of the patients. The valve size implanted was similar in both groups. Device success was higher in direct TAVI (85% vs. 64%, p = 0.014), mostly driven by a significant lower incidence of paravalvular leak (PVL ≥2; 9% vs. 33%, p = 0.02). Safety combined end point at 30 days was similar in both groups. Conclusion: Compared to TAVI with pre-dilation, direct TAVI is feasible regardless of the presence of bulky calcified aortic valve and the valve size implanted. Device success was higher in direct TAVI, mostly driven by a lower incidence of paravalvular leak. Safety at 30 days was similar in two groups.

  10. Stent valve implantation in conventional redo aortic valve surgery to prevent patient-prosthesis mismatch.

    Science.gov (United States)

    Ferrari, Enrico; Franciosi, Giorgio; Clivio, Sara; Faletra, Francesco; Moccetti, Marco; Moccetti, Tiziano; Pedrazzini, Giovanni; Demertzis, Stefanos

    2017-03-01

    The goal was to show the technical details, feasibility and clinical results of balloon-expandable stent valve implantation in the aortic position during conventional redo open-heart surgery in selected obese patients with a small aortic prosthesis and severe patient-prosthesis mismatch. Two symptomatic overweight patients (body mass index of 31 and 38), each with a small aortic prosthesis (a 4-year-old, 21-mm Hancock II biological valve and a 29-year-old, 23-mm Duromedic mechanical valve), increased transvalvular gradients (59/31 and 74/44 mmHg) and a reduced indexed effective orifice area (0.50 and 0.43 cm 2 /m 2 ) underwent implantation of two 26-mm balloon-expandable Sapien 3 valves during standard on-pump redo valve surgery. Using full re-sternotomy, cardiopulmonary bypass and cardioplegic arrest, the two balloon-expandable stent valves were implanted under direct view using a standard aortotomy, after prosthesis removal and without annulus enlargement. Aortic cross-clamp times were 162 and 126 min; cardiopulmonary bypass times were 178 and 180 min; total surgical times were 360 and 318 min. At discharge, echocardiograms showed transvalvular peak and mean gradients of 13/9 and 23/13 mmHg and indexed effective orifice areas of 0.64 and 1.08 cm 2 /m 2 . The 3-month echocardiographic follow-up showed transvalvular peak and mean gradients of 18/9 and 19/11 mmHg and indexed effective orifice areas of 0.78 cm 2 /m 2 and 0.84 cm 2 /m 2 , with improved symptoms (New York Heart Association class 1). Implantation of a balloon-expandable stent valve during redo aortic valve surgery is feasible in selected cases and prevents patient-prosthesis mismatch in obese patients without need for aortic annulus enlargement. Moreover, in the case of stent valve degeneration, this approach permits additional valve-in-valve procedures with large stent valves and prevents re-redo surgery. © The Author 2016. Published by Oxford University Press on behalf of the

  11. Risk stratification by pre-operative cardiopulmonary exercise testing improves outcomes following elective abdominal aortic aneurysm surgery: a cohort study.

    Science.gov (United States)

    Goodyear, Stephen J; Yow, Heng; Saedon, Mahmud; Shakespeare, Joanna; Hill, Christopher E; Watson, Duncan; Marshall, Colette; Mahmood, Asif; Higman, Daniel; Imray, Christopher He

    2013-05-19

    In 2009, the NHS evidence adoption center and National Institute for Health and Care Excellence (NICE) published a review of the use of endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms (AAAs). They recommended the development of a risk-assessment tool to help identify AAA patients with greater or lesser risk of operative mortality and to contribute to mortality prediction.A low anaerobic threshold (AT), which is a reliable, objective measure of pre-operative cardiorespiratory fitness, as determined by pre-operative cardiopulmonary exercise testing (CPET) is associated with poor surgical outcomes for major abdominal surgery. We aimed to assess the impact of a CPET-based risk-stratification strategy upon perioperative mortality, length of stay and non-operative costs for elective (open and endovascular) infra-renal AAA patients. A retrospective cohort study was undertaken. Pre-operative CPET-based selection for elective surgical intervention was introduced in 2007. An anonymized cohort of 230 consecutive infra-renal AAA patients (2007 to 2011) was studied. A historical control group of 128 consecutive infra-renal AAA patients (2003 to 2007) was identified for comparison.Comparative analysis of demographic and outcome data for CPET-pass (AT ≥ 11 ml/kg/min), CPET-fail (AT 11 ml/kg/min was associated with reduced perioperative mortality (open cases only), LOS, survival and inpatient costs (open and endovascular repair) for elective infra-renal AAA surgery.

  12. Daily concurrent preoperative chemoradiotherapy using new superselective intra-arterial infusion via superficial temporal artery for oral cancer. Cervical lymph node metastasis

    International Nuclear Information System (INIS)

    Yamamoto, Noriyuki; Mitsudo, Kenji; Tohnai, Iwai

    2007-01-01

    Seventeen oral cancer patients with cervical lymph node metastasis were treated by preoperative chemoradiotherapy using superselective intra-arterial infusion via the superficial temporal artery. Radiotherapy (total dose: 40 Gy/4 weeks) and superselective intra-arterial infusion chemotherapy using docetaxel (DOC) (total dose: 60 mg/m 2 , 15 mg/m 2 /week) and cisplatin (CDDP) (total dose: 100 mg/m 2 , 5 mg/m 2 /day) were performed, followed by surgery. The pathological effects of resected lymph node metastasis after surgery were grade III, IV (Oboshi-Shimosato classification) in level I, II. This method is a promising strategy for oral cancer with cervical lymph node metastasis. (author)

  13. Thoracic aortic aneurysms and dissections: endovascular treatment.

    Science.gov (United States)

    Baril, Donald T; Cho, Jae S; Chaer, Rabih A; Makaroun, Michel S

    2010-01-01

    The treatment of thoracic aortic disease has changed radically with the advances made in endovascular therapy since the concept of thoracic endovascular aortic repair was first described 15 years ago. Currently, there is a diverse array of endografts that are commercially available to treat the thoracic aorta. Multiple studies, including industry-sponsored and single-institution reports, have demonstrated excellent outcomes of thoracic endovascular aortic repair for the treatment of thoracic aortic aneurysms, with less reported perioperative morbidity and mortality in comparison with conventional open repair. Additionally, similar outcomes have been demonstrated for the treatment of type B dissections. However, the technology remains relatively novel, and larger studies with longer term outcomes are necessary to more fully evaluate the role of endovascular therapy for the treatment of thoracic aortic disease. This review examines the currently available thoracic endografts, preoperative planning for thoracic endovascular aortic repair, and outcomes of thoracic endovascular aortic repair for the treatment of both thoracic aortic aneurysms and type B aortic dissections. Mt Sinai J Med 77:256-269, 2010. (c) 2010 Mount Sinai School of Medicine.

  14. Nuclear cardiac ejection fraction and cardiac index in abdominal aortic surgery

    International Nuclear Information System (INIS)

    Fiser, W.P.; Thompson, B.W.; Thompson, A.R.; Eason, C.; Read, R.C.

    1983-01-01

    Since atherosclerotic heart disease results in more than half of the perioperative deaths that follow abdominal aortic surgery, a prospective protocol was designed for preoperative evaluation and intraoperative hemodynamic monitoring. Twenty men who were prepared to undergo elective operation for aortoiliac occlusive disease (12 patients) and abdominal aortic aneurysm (eight patients) were evaluated with a cardiac scan and right heart catheterization. The night prior to operation, each patient received volume loading with crystalloid based upon ventricular performance curves. At the time of the operation, all patients were anesthetized with narcotics and nitrous oxide, and hemodynamic parameters were recorded throughout the operation. Aortic crossclamping resulted in a marked depression in CI in all patients. CI remained depressed after unclamping in the majority of patients. There were two perioperative deaths, both from myocardial infarction or failure. Both patients had ejection fractions less than 30% and initial CIs less than 2 L/M2, while the survivors' mean ejection fraction was 63% +/- 1 and their mean CI was 3.2 L/M2 +/- 0.6. The authors conclude that preoperative evaluation of ejection fraction can select those patients at a high risk of cardiac death from abdominal aortic operation. These patients should receive intensive preoperative monitoring with enhancement of ventricular performance

  15. Radiotherapy-induced aortic valve disease associated with porcelain aorta

    International Nuclear Information System (INIS)

    Daitoku, Kazuyuki; Fukui, Kozo; Ichinoseki, Ikkoh; Munakata, Mamoru; Takahashi, Shoichi; Fukuda Ikuo

    2004-01-01

    Mediastinal irradiation has been reported to induce cardiac disease such as pericarditis, valvular dysfunction, conduction abnormalities, accelerated arteriosclerosis of the coronary arteries, and also calcifications of the ascending aorta. We herein describe a case of radiotherapy-induced porcelain aorta and aortic valve disease and their surgical treatment. The patient was diagnosed with myasthenia gravis (MG) in 1965 (Osserman's type II), and mediastinal irradiation was performed in 1970 for treatment of thymic tumor associated with MG. Thirty years after radiation therapy, complete atrioventricular block and aortic valve disease with severe calcification of the ascending aorta and aortic arch (porcelain aorta) were detected on echo cardiogram and cardiac catheterization. A permanent pacemaker was implanted via the left subclavian vein and aortic valve replacement was performed under extracorporeal circulation established by selective cerebral perfusion and balloon occlusion instead of aortic cross-clamping. As no risk factors of arteriosclerosis such as hypercholesterolemia, hyperglycemia and hypertension were apparent, we concluded that the aortic valve disease and porcelain aorta were primarily induced by radiotherapy. (author)

  16. Feasibility of Angioplasty and Stenting for Abdominal Aortic Lesions Adjacent to Previously Stented Visceral Artery Lesions in Patients with Takayasu Arteritis

    International Nuclear Information System (INIS)

    Joseph, George; George, Paul V.; Pati, Purendra Kumar; Chandy, Sunil Thomas

    2007-01-01

    Two young female patients with Takayasu arteritis presented with symptomatic long-segment abdominal aortic stenosis in the vicinity of previously deployed celiac and renal artery stents that projected markedly into the narrowed aortic lumen. Crushing or distortion of the visceral artery stents during aortic angioplasty was avoided by performing simultaneous or alternating balloon dilatations in the aorta and in the visceral artery stents. Consequently, the visceral artery stents remained patent and shortened longitudinally, allowing unhindered deployment of Wallstents in the adjacent aorta and abolition of a pressure gradient across the aortic lesions. Access to side branches covered by the Wallstent was obtained without difficulty, enabling the performance of balloon dilatation in multiple side branches and ostial stent deployment in a renal artery. These techniques could increase the scope of endovascular therapy in the treatment of patients with Takayasu arteritis

  17. Assessment of value of spiral CT in preoperative evaluation of endovascular graft exclusion for abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Jing Zaiping; Zhao Jun; Zhu Wenjiang; Xiao Yi

    1998-01-01

    Purpose: The assess the value of spiral CT (SCT) in preoperative evaluation of endovascular graft exclusion (EVGE) for abdominal aortic aneurysm (AAA). Methods: 41 case with AAA received SCT scanning. Two and three dimensional images were reconstructed, utilizing the shaded surface display (SSD), maximum-intensity Projection (MIP) and multiplanar reformation (MPR). Information were obtained regarding the size and features of AAA, length and diameters of aneurysm's neck, status of the branches of aorta, etc. Results: Nine patients had spinal CT study prior EVGE procedure and the grafts selected according to the parameters obtained by SCT matched perfectly to the needs of deployment. Conclusion: CTA provides high quality images. It is a high-speed and non-invasive method which can provide three-dimensional images of AAA and its main branches and all the parameters needed in EVGE

  18. Heart failure - surgeries and devices

    Science.gov (United States)

    ... surgery; HF - surgery; Intra-aortic balloon pumps - heart failure; IABP - heart failure; Catheter based assist devices - heart failure ... problem may cause heart failure or make heart failure worse. Heart valve surgery may be needed to repair or ...

  19. Management of patients with hematological malignancies undergoing coronary artery bypass grafting

    Directory of Open Access Journals (Sweden)

    Deepak Borde

    2013-01-01

    Full Text Available The number of patients with a previously diagnosed malignancy who need cardiac surgery is increasing. Patients with hematological malignancies represent only 0.38% of all patients undergoing cardiac surgery. The literature in this subset of patients is limited to only a few retrospective case series, with limited number of patients undergoing emergency cardiac surgery. We describe three cases with hematological malignancies namely chronic myelogenous leukemia, acute promyelocytic leukemia and chronic lymphocytic leukemia presenting for coronary artery bypass grafting (CABG. Two patients were taken up for emergency CABG in view of ongoing ischemia, one of them was on preoperative intra-aortic balloon pump support. No mortality was observed. Two patients needed transfusion of blood products which was guided by thromboelastography. One patient developed superficial sternal wound infection requiring antibiotic therapy.

  20. Aortic embolization of an Edwards SAPIEN prosthesis due to sigmoid left ventricular hypertrophy: Case report.

    Science.gov (United States)

    Yuksel, Isa Öner; Koklu, Erkan; Arslan, Sakir; Cagirci, Goksel; Kucukseymen, Selcuk

    2016-06-01

    Transcatheter aortic valve implantation (TAVI) is considered an alternative therapy in high-risk patients with severe aortic stenosis. Although a minimally invasive procedure, it is not free from complications, one of which is valve embolization at the time of TAVI. We present a case of embolization of a balloon-expandable aortic valve due to sigmoid left ventricular hypertrophy and managed with a second valve without surgery. The embolized valve was repositioned in the aortic arch between the left common carotid artery and the brachiocephalic trunk. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  1. Results of aortic root reimplantation in patients with ascending aortic aneurysm and concomitant aortic insufficiency

    Directory of Open Access Journals (Sweden)

    А. М. Чернявский

    2016-01-01

    Full Text Available Objective. The research was designed to evaluate the results of valve-sparing operations: aortic root reimplantation versus aortic valve reimplantation when repairing an ascending aortic aneurysm with concomitant aortic insufficiency.Methods. Within a blind prospective randomized study conducted over a period from 2011 to 2015, 64 patients underwent aortic valve-sparing surgery. The inclusion criteria were the presence of an aortic aneurysm of the ascending aorta exceeding 4.5 cm and concomitant aortic insufficiency. All patients were divided into two groups: FS-group, aortic root reimplantation (modified Florida Sleeve technique (n = 32 and D-group, aortic valve reimplantation (David procedure (n = 32. The average age of patients was 57±13 (23–73 years in the FS-group and 55±11 (15–72 years in the D-group (p = 0.54. Both groups had 78% of males (p>0.99. A Marfan syndrome was identified in 6% and 9% in the FS-group and D-group respectively (p>0.99. Mean diameter of the sinuses of Valsalva was 51±7 mm and 56±10 mm (p = 0.09, aortic insufficiency 2.6±0.7 and 2.8±0.8 (p = 0.15 in the FS-group and D-group respectively. In the FS-group and D-group LVEDD amounted to 5.5±0.7 mm and 5.9±1.0 mm (p = 0.09 respectively. All patients took echocardiography in the preoperative, postoperative and follow-up periods.Results. In the long-term period, the degree of aortic regurgitation was 1.2±0.1 in the FS-group and 1.3±0.6 in the D-group (p = 0.72. LVEDD was 123±23 mm in the FS-group and 139.6±80 mm in the D-group at follow-up (p = 0.77. There were no statistically significant differences in the analysis of complications. Overall 30-day in-hospital mortality was 7.8%. There were 2 (6.3% deaths in the FS-group and 3 (9.4% in the D-group (p = 0.5.Late mortality was 6.3% in the FS-group and 3.1% in the D-group (p>0.99. Cumulative survival at 4 years was 84.3% and 84.8% in the FS-group and the D-group respectively (p = 0.94. Cumulative freedom from

  2. The Effect of Infrarenal Aortic Balloon Occlusion on Weaning from Supraceliac Aortic Balloon Occlusion in a Porcine Model (Sus scrofa) of Hemorrhagic Shock

    Science.gov (United States)

    2017-06-15

    all animals , and continued for six hours. Half of the animals were randomly assigned to Zone-3 REBOA for an additional 45 minutes following Zone-1...concentration or resuscitation requirements.Conclusion: In an animal model of hemorrhagic shock and Zone-1 REBOA, subsequent Zone-3 aortic occlusion did not add

  3. Endoscopic ultrasound with double-balloon endoscopy for the diagnosis of inverted Meckel’s diverticulum: a case report

    Directory of Open Access Journals (Sweden)

    Araki Akihiro

    2012-09-01

    Full Text Available Abstract Introduction Inverted Meckel’s diverticulum has usually been misdiagnosed in the cases based on computed tomography images presented in the literature. The final diagnosis was made intra-operatively or by pathology reports after surgery. Despite this, preoperative diagnosis could be made successfully by using endoscopic ultrasound with double-balloon endoscopy prior to surgery. Case presentation A 60-year-old Japanese woman with severe anemia complained of several episodes of black stool over the preceding 2 years. Abdominal computed tomography showed a 3.0-cm low-density tumor in the ileum, suggesting a diagnosis of intestinal lipoma. Examination of the tumor by endoscopic ultrasound with double-balloon endoscopy revealed a hypo-echoic layer corresponding to the muscularis propria, and a hyper-echoic layer corresponding to the fat tissue. These findings, which suggested that the tumor included areas outside the intestinal serosa, are not typical for a lipoma, despite the existence of a hyper-echoic layer corresponding to fatty tissue. We then considered a diagnosis of inverted Meckel’s diverticulum. Conclusion Lipoma and inverted Meckel’s diverticulum are difficult to differentially diagnose by computed tomography. Polypectomy is the preferred therapeutic approach when a lipoma is present; however, polypectomy in a patient with Meckel’s diverticulum requires full-thickness resection. Situations where polypectomy is performed without preparing for full-thickness resection can be avoided by first making a precise diagnosis using double-balloon endoscopy and endoscopic ultrasound.

  4. An anaesthetic pre-operative assessment clinic reduces pre-operative inpatient stay in patients requiring major vascular surgery.

    LENUS (Irish Health Repository)

    O'Connor, D B

    2012-02-01

    BACKGROUND: Patients undergoing major vascular surgery (MVS) require extensive anaesthetic assessment. This can require extended pre-operative stays. AIMS: We investigated whether a newly established anaesthetic pre-operative assessment clinic (PAC) would reduce the pre-operative inpatient stay, avoid unnecessary investigations and facilitate day before surgery (DBS) admissions for patients undergoing MVS. PATIENT AND METHODS: One year following and preceding the establishment of the PAC the records of patients undergoing open or endovascular aortic aneurysm repair, carotid endarterectomy and infra-inguinal bypass were reviewed to measure pre-operative length of stay (LoS). RESULTS: Pre-operative LoS was significantly reduced in the study period (1.85 vs. 4.2 days, respectively, P < 0.0001). Only 12 out of 61 patients in 2007 were admitted on the DBS and this increased to 33 out of 63 patients (P = 0.0002). No procedure was cancelled for medical reasons. CONCLUSION: The PAC has facilitated accurate outpatient anaesthetic assessment for patients requiring MVS. The pre-operative in-patient stay has been significantly reduced.

  5. [Valvuloplasty with balloon catheter in biologic prosthesis. Reality or illusion].

    Science.gov (United States)

    Ledesma Velasco, M; Verdín Vázquez, R; Acosta Valdez, J L; Munayer Calderón, J; Salgado Escobar, J L; Arias Monroy, L; Flores Mendoza, J

    1989-01-01

    We performed catheter balloon valvuloplasty (CBV) on 8 stenotic operatively-excised bioprosthetic valves (2 Hancock and 6 Ionescu Shiley). Pathology of valves before CBV included degenerative changes: commissural fusion by mounds of calcific deposits (2 valves), fibrotic and focally calcified leaflets (7 valves) and stiff and thick valves (1 valve). Inflation of the balloon resulted in commissural splitting (2 valves), leaflet cracks and fractures (3 valves). Removal of the deflated balloon catheter was associated with debris dislodgement (3 valves). In one case the valve was unable to close with potential for acute regurgitation. Thus, CBV of bioprosthetic valves can split fused commissures by similar mechanisms as in native valves. CBV may fracture calcific deposits causing acute emboli. It can also disrupt the leaflets causing acute insufficiency. The findings suggest a limited role of CBV in the treatment of stenotic bioprosthetic valves in mitral and aortic position.

  6. Application and influence of preoperative intervention intra-arterial chemotherapy (NAC) of uterine artery for endometrial carcinoma

    International Nuclear Information System (INIS)

    Zhu Xueqiong; Yue Tianfu; Wang Dehua

    2001-01-01

    Objective: To analyse the effect of preoperative persistent infusion chemotherapy via uterine artery on endometrial carcinoma and followed by hysterectomy. Methods: According to the Seldinger's technique, polyethylene catheter was super selected into the uterine artery. The drugs were infused with cisplatin 100 mg and doxorubicin 50 mg in a consecutive low-dose method for five days. Radical surgery was performed about three or four weeks after NAC. The NAC group (n = 20) underwent surgery following intra-arterial chemotherapy, while the control group (n = 40) was randomly selected among the patients of endometrial carcinoma performed operations in the hospital. Results: One (5.0%) patient showed complete response in NAC group, the rates of complete response plus partial response were 60.0%. There were no significant differences in bleeding amounts, the operation time, the function recovery of bladder and bowel, the healing time of the incision between the two groups. Compared with the control group, infiltration larger than half of myometrium and lymph nodes involvement were statistically significant lower in NAC group (P < 0.05). Conclusions: Preparing intra-arterial chemotherapy may reduce tumor volume and possibly eradicate subclinical metastases without increasing the incidence of operative complications

  7. Endoluminal treatment of aortic dissection

    Energy Technology Data Exchange (ETDEWEB)

    Chavan, Ajay; Lotz, Joachim; Galanski, Michael [Department of Diagnostic Radiology, Hannover Medical School, Carl Neuberg Strasse 1, 30625, Hannover (Germany); Oelert, Frank; Haverich, Axel; Karck, Matthias [Department of Thoracic and Cardiovascular Surgery, Hannover Medical School, Carl Neuberg Strasse 1, 30625, Hannover (Germany)

    2003-11-01

    Aortic dissection is most often a catastrophic medical emergency which, if untreated, can be potentially fatal. The intention of therapy in patients with aortic dissection is to prevent aortic rupture or aneurysm formation as well as to relieve branch vessel ischaemia. Patients with aortic dissection are often poor candidates for anaesthesia and surgery and the surgical procedure itself is challenging requiring thoracotomy, aortic cross clamping, blood transfusion as well as prolonged hospital stay in some cases. Operative mortality is especially high in patients with critical mesenteric or renal ischaemia. The past decade has experienced the emergence of a number of interventional radiological or minimally invasive techniques which have significantly improved the management of patients with aortic dissection. These include stent grafting for entry site closure to prevent aneurysmatic widening of the false lumen as well as percutaneous techniques such as balloon fenestration of the intimal flap and aortic true lumen stenting to alleviate branch vessel ischaemia. False lumen thrombosis following entry closure with stent grafts has been observed in 86-100% of patients, whereas percutaneous interventions are able to effectively relieve organ ischaemia in approximately 90% of the cases. In the years to come, it is to be expected that these endoluminal techniques will become the method of choice for treating most type-B dissections and will assist in significantly reducing the number of open surgical procedures required for type-A dissections. The intention of this article is to provide an overview of the current status of these endoluminal techniques based on our own experience as well as on a review of the relevant literature. (orig.)

  8. Endoluminal treatment of aortic dissection

    International Nuclear Information System (INIS)

    Chavan, Ajay; Lotz, Joachim; Galanski, Michael; Oelert, Frank; Haverich, Axel; Karck, Matthias

    2003-01-01

    Aortic dissection is most often a catastrophic medical emergency which, if untreated, can be potentially fatal. The intention of therapy in patients with aortic dissection is to prevent aortic rupture or aneurysm formation as well as to relieve branch vessel ischaemia. Patients with aortic dissection are often poor candidates for anaesthesia and surgery and the surgical procedure itself is challenging requiring thoracotomy, aortic cross clamping, blood transfusion as well as prolonged hospital stay in some cases. Operative mortality is especially high in patients with critical mesenteric or renal ischaemia. The past decade has experienced the emergence of a number of interventional radiological or minimally invasive techniques which have significantly improved the management of patients with aortic dissection. These include stent grafting for entry site closure to prevent aneurysmatic widening of the false lumen as well as percutaneous techniques such as balloon fenestration of the intimal flap and aortic true lumen stenting to alleviate branch vessel ischaemia. False lumen thrombosis following entry closure with stent grafts has been observed in 86-100% of patients, whereas percutaneous interventions are able to effectively relieve organ ischaemia in approximately 90% of the cases. In the years to come, it is to be expected that these endoluminal techniques will become the method of choice for treating most type-B dissections and will assist in significantly reducing the number of open surgical procedures required for type-A dissections. The intention of this article is to provide an overview of the current status of these endoluminal techniques based on our own experience as well as on a review of the relevant literature. (orig.)

  9. Fracture of the delivery balloon shaft during balloon-expandable prosthesis alignment during implantation of an Edwards SAPIEN 3.

    Science.gov (United States)

    Arai, Takahide; Hovasse, Thomas; Chevalier, Bernard

    2018-04-01

    The expandable sheath was designed with a lower profile in order to reduce the incidence of vascular complications of transcatheter aortic valve implantation using transfemoral approach. However, once the prosthesis has crossed the sheath, it could be difficult to retrieve it from the body. This is the first case of successful bail-out in an instance of delivery balloon shaft malfunction subsequent to the crossing of an expandable sheath during implantation of an Edwards SAPIEN 3 prosthesis. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  10. Significant skin burns may occur with the use of a water balloon in HIFU treatment

    Science.gov (United States)

    Ritchie, Robert; Collin, Jamie; Wu, Feng; Coussios, Constantin; Leslie, Tom; Cranston, David

    2012-10-01

    HIFU is a minimally-invasive therapy suitable for treating selected intra-abdominal tumors. Treatment is safe although skin burns may occur due to pre-focal heating. HIFU treatment of a renal transplant tumor located in the left lower abdomen was undertaken in our centre. Treatment was performed prone, requiring displacement of the abdominal wall away from the treatment field using a water balloon, constructed of natural rubber latex and filled with degassed water. Intra-operatively, ultrasound imaging and physical examination of the skin directly over the focal region was normal. Immediately post-operative, a full-thickness skin burn was evident at the periphery of the balloon location, outside the expected HIFU path. Three possibilities may account for this complication. Firstly, the water balloon may have acted as a lens, focusing the HIFU to a neo-focus off axis. Secondly, air bubbles may have been entrapped between the balloon and the skin, causing heating at the interface. Finally, heating of the isolated water within the balloon may have been sufficient to cause burning. In this case, the placement of a water balloon caused a significant skin burn. Care should be taken in their use as burns, situated off axis, may occur even if the overlying skin appears normal.

  11. 3D echocardiographic analysis of aortic annulus for transcatheter aortic valve replacement using novel aortic valve quantification software: Comparison with computed tomography.

    Science.gov (United States)

    Mediratta, Anuj; Addetia, Karima; Medvedofsky, Diego; Schneider, Robert J; Kruse, Eric; Shah, Atman P; Nathan, Sandeep; Paul, Jonathan D; Blair, John E; Ota, Takeyoshi; Balkhy, Husam H; Patel, Amit R; Mor-Avi, Victor; Lang, Roberto M

    2017-05-01

    With the increasing use of transcatheter aortic valve replacement (TAVR) in patients with aortic stenosis (AS), computed tomography (CT) remains the standard for annulus sizing. However, 3D transesophageal echocardiography (TEE) has been an alternative in patients with contraindications to CT. We sought to (1) test the feasibility, accuracy, and reproducibility of prototype 3DTEE analysis software (Philips) for aortic annular measurements and (2) compare the new approach to the existing echocardiographic techniques. We prospectively studied 52 patients who underwent gated contrast CT, procedural 3DTEE, and TAVR. 3DTEE images were analyzed using novel semi-automated software designed for 3D measurements of the aortic root, which uses multiplanar reconstruction, similar to CT analysis. Aortic annulus measurements included area, perimeter, and diameter calculations from these measurements. The results were compared to CT-derived values. Additionally, 3D echocardiographic measurements (3D planimetry and mitral valve analysis software adapted for the aortic valve) were also compared to the CT reference values. 3DTEE image quality was sufficient in 90% of patients for aortic annulus measurements using the new software, which were in good agreement with CT (r-values: .89-.91) and small (software can accurately measure aortic annulus in patients with severe AS undergoing TAVR, in better agreement with CT than the existing methodology. Accordingly, intra-procedural TEE could potentially replace CT in patients where CT carries significant risk. © 2017, Wiley Periodicals, Inc.

  12. [Prediction of intra-abdominal hypertension risk in patients with acute colonic obstruction under epidural analgesia].

    Science.gov (United States)

    Stakanov, A V; Potseluev, E A; Musaeva, T S

    2013-01-01

    Purpose of the study was to identify prediction possibility of direct current potential level for intra-abdominal hypertension risk in patients with acute colonic obstruction under preoperative epidural analgesia. Prospective analysis of the preoperative period was carried out in 140 patients with acute colonic obstruction caused by colon cancer. Relations between preoperative level of permanent capacity and risk of intra-abdominal hypertension was identified Direct current potential level is an independent predictor of intra-abdominal hypertension. Diagnostic significance increases from first to fifth hour of preoperative period according to AUROC data from 0.821 to 0.905 and calibration 6.9 (p > 0.37) and 4.7 (p > 0.54) by Hosmer-Lemeshou criteria. The use of epidural analgesia in the complex intensive preoperative preparation is pathogenically justified. It reduces intra-abdominal hypertension in patients with acute colonic obstruction.

  13. [Application of TB type thermal balloon endometrial ablation for the treatment of abnormal uterine bleeding].

    Science.gov (United States)

    Wang, W; Zhai, Y; Zhang, Z H; Li, Y; Zhang, Z Y

    2016-11-08

    Objective: To investigate the clinical efficacy, safety and promotion value of TB type thermal balloon endometrial ablation in the treatment of abnormal uterine bleeding. Methods: Fourty three patients who had received TB type endometrial ablation system for treatment of abnormal uterine bleeding from January, 2015 to January, 2016 in theDepartment of gynecology, Beijing Chaoyang Hospital were enrolled in this study. The intra-operative and post-operative complications and improvement of abnormal uterine bleeding and dysmenorrhea were observed. Results: There were nointra-operative complication occurred, such as uterine perforation, massive hemorrhage or surrounding organ damage. At 6 months after operation, 32 patients developed amenorrhea, 6 developed menstrual spotting, 3 developed menstruation with a small volume and 1 had a normal menstruation. No menstruation with an increased volume occurred. The occurrence of amenorrhea was 76.19% and the response rate was 97.62%.At 6 months after operation, 1 case had no response, 2 cases had partial response and 11 cases had complete response among the 14 cases of pre-operative dysmenorrhea; only 3 cases still had anemia among the 23 cases of pre-operative anemia. Compared with before treatment, patients with dysmenorrhea and anemia both significantly reduced with a statistically significant difference( P abnormal uterine bleeding, which could have clinical promotion practice.

  14. Retro-aortic, left inferior renal capsular vein

    Directory of Open Access Journals (Sweden)

    Umberto G Rossi

    2015-01-01

    Full Text Available In our case report, abdominal multi-detector computed tomography was used for the pre-operative anatomy evaluation in a living kidney donor. The early phase of the test revealed normal kidneys in the donor. The vascular phase detected a venous variant on the left side: An inferior renal capsular vein, which had a loop and a retro-aortic course. This preoperative knowledge was crucial for the laparoscopic nephrectomy as a surgical procedure for harvesting kidney from the living donor.

  15. Enhanced left ventricular mass regression after aortic valve replacement in patients with aortic stenosis is associated with improved long-term survival.

    Science.gov (United States)

    Ali, Ayyaz; Patel, Amit; Ali, Ziad; Abu-Omar, Yasir; Saeed, Amber; Athanasiou, Thanos; Pepper, John

    2011-08-01

    Aortic valve replacement in patients with aortic stenosis is usually followed by regression of left ventricular hypertrophy. More complete resolution of left ventricular hypertrophy is suggested to be associated with superior clinical outcomes; however, its translational impact on long-term survival after aortic valve replacement has not been investigated. Demographic, operative, and clinical data were obtained retrospectively through case note review. Transthoracic echocardiography was used to measure left ventricular mass preoperatively and at annual follow-up visits. Patients were classified according to their reduction in left ventricular mass at 1 year after the operation: group 1, less than 25 g; group 2, 25 to 150 g; and group 3, more than 150 g. Kaplan-Meier and multivariable Cox regression were used. A total of 147 patients were discharged from the hospital after aortic valve replacement for aortic stenosis between 1991 and 2001. Preoperative left ventricular mass was 279 ± 98 g in group 1 (n = 47), 347 ± 104 g in group 2 (n = 62), and 491 ± 183 g in group 3 (n = 38) (P regression such as ischemic heart disease or hypertension, valve type, or valve size used. Ten-year actuarial survival was not statistically different in patients with enhanced left ventricular mass regression when compared with the log-rank test (group 1, 51% ± 9%; group 2, 54% ± 8%; and group 3, 72% ± 10%) (P = .26). After adjustment, left ventricular mass reduction of more than 150 g was demonstrated as an independent predictor of improved long-term survival on multivariate analysis (P = .02). Our study is the first to suggest that enhanced postoperative left ventricular mass regression, specifically in patients undergoing aortic valve replacement for aortic stenosis, may be associated with improved long-term survival. In view of these findings, strategies purported to be associated with superior left ventricular mass regression should be considered when undertaking

  16. Early outcome of mini aortic valve replacement surgery

    Directory of Open Access Journals (Sweden)

    Shawky Fareed

    2018-03-01

    Full Text Available Background: Minimally invasive aortic valve surgery (MIAVS has evolved into a well-tolerated, efficient surgical treatment option in experienced centers, providing greater patient satisfaction and lower complication rates. Potential advantages of MIAVR arise from the concept that patient morbidity and potential mortality could be reduced without compromising the excellent results of the conventional procedure which include improved cosmetic results, safer access in the case of reoperation, less postoperative bleeding, lower intensive care unit (ICU and in-hospital stays, as well as the absence of sternal wound infection. These results were achievable also in high-risk patients. Reduced pain and hospital length of stay, decreased time until return to full activity and decreased blood product use have also been demonstrated. Methods: Sixty patients with aortic valve disease randomized into two equal groups; group “A” underwent aortic valve surgery through a minimally invasive limited upper sternotomy. Group “B” underwent aortic valve surgery through a full median sternotomy. The Pain was evaluated on 2nd, 3rd day post-operatively and at the 3rd, 6th month after discharge. Echocardiographic data were performed preoperatively and at the 3rd, 6th month after discharge in all patients. Standard aortic and bicaval cannulation with cold antegrade crystalloid cardioplegia was adopted in group“B”, while in group “A” femoral vein with ascending aortic cannulation was adopted with antegrade blood cardioplegia. Results: There was no statistical difference between the two groups preoperatively regarding their age, sex, NYHA class, EF%, LA dimension, spirometric study. There was no operative mortality in both groups but few postoperative complications occurred in both groups. Total hospital stay, ICU stay, postoperative bleeding, inotropic requirement, ventilatory support, blood transfusion was less in group “A”, with better cosmetic

  17. Effect of Body Mass Index on Postoperative Complications in ...

    African Journals Online (AJOL)

    Postoperative stroke, postoperative atrial fibrillation (AF) and intra-aortic balloon pump (IABP) use were not associated with BMI. In linear regression analysis, significant correlations between low BMI, reintubation, ICU stay time and intubation time were found. Re-exploration for bleeding was significantly correlated with ...

  18. MR imaging of aortic coarctation

    International Nuclear Information System (INIS)

    Beslic, S.

    2004-01-01

    Purpose. The purpose of this paper is to analyse the contribution of MRI as diagnostic procedure in the preoperative diagnosis of aortic coarctation (CoA), in patients with clinical and echocardiographic suspicion for this disease. Patients and methods. During the period of three years, eight patients were examined, 5 (62.5%) male and 3 (37.5%) female patients with clinical echocardiographic suspicion of CoA. The ratio between male and female patients was 1.7 : 1. The youngest patient was 3 and the oldest 46 years (median age was 15 years). Without administration of contrast media and using body coil the examinations were performed with MR machine Magnetom 1.0 Tesla ( S iemens ) , with the slice thickness of 6 mm, Fast spin-echo (FSE) T1W sequences, Cine gradient echo (GRE) sequence with slab 7 mm and time of flight (TOF) sequence with MIP reconstructions were applied. During the examinations the patients underwent also ECG gating. Examinations were done in axial, coronal and oblique sagittal projections with measuring of the dimensions of cardiovascular structures. Results. CoA was found in 8 (100%) patients. In 7 (87.5%) cases, coarctation developed at isthmus and in one case, coarctation was detected at the horizontal part of aortic arch, between the truncus arteriosus of the left carotid communis artery. Aortal insufficiency was found in 7 (87.5%) patients; in four of them (50%), bicuspidia was confirmed (bicuspid aortic valve), 7 (87.5%) patients had slightly expressed hypertrophy of the left ventricle. Two (25%) patients had dilatation of the ascendant aorta, six (75%) wider outgoing vessels of the aortic arch, four (50%) had well developed arterial collaterals and 2 (25%) patients rib notching. In 2 (25%) patients as side finding thymus persistent was found. Average diameter of coarctation was 10 mm. In one patient, CoA was accompanied with stenosis of pulmonary artery, in one with ventricular septal defect, and one with tricuspid insufficiency. The results

  19. The preoperative evaluation prevent the postoperative complications of thyroidectomy

    Directory of Open Access Journals (Sweden)

    Chien-Feng Huang

    2015-03-01

    Conclusions: The success of thyroid surgery depends on careful preoperative planning, including a preoperative neck ultrasound to determine the proximity of the nodule to the recurrent laryngeal nerve course, and the consideration of the type of anesthesia, adjuvant devices for intra-op monitoring of the RLN, and surgical modalities. Our results suggest that preoperative evaluation implementations are positively associated with strategy of surgery and postoperative hypocalcemia prevention.

  20. Endovascular Treatment of Occlusive Lesions in the Aortic Bifurcation with Kissing Polytetrafluoroethylene-Covered Stents

    NARCIS (Netherlands)

    Grimme, F.A.B.; Spithoven, J.H.; Zeebregts, C.J.A.; Scharn, D.M.; Reijnen, M.M.

    2015-01-01

    PURPOSE: To determine the clinical outcomes of polytetrafluoroethylene covered balloon expandable stents (CBESs) in occlusive lesions of the aortic bifurcation in a kissing stent configuration. MATERIALS AND METHODS: The study included 69 consecutive patients (29 men, 40 women) who underwent kissing

  1. Endovascular Treatment of Occlusive Lesions in the Aortic Bifurcation with Kissing Polytetrafluoroethylene-Covered Stents

    NARCIS (Netherlands)

    Grimme, Frederike A. B.; Spithoven, J. Hans; Zeebregts, Clark J.; Scharn, Dirk M.; Reijnen, Michel M. P. J.

    Purpose: To determine the clinical outcomes of polytetrafluoroethylene covered balloon expandable stents (CBESs) in occlusive lesions of the aortic bifurcation in a kissing stent configuration. Materials and Methods: The study included 69 consecutive patients (29 men, 40 women) who underwent kissing

  2. Daily concurrent preoperative chemoradiotherapy using superselective intra-arterial infusion via superficial temporal artery for advanced oral cancer. Histological evaluation of metastatic cervical lymph nodes

    International Nuclear Information System (INIS)

    Mitsudo, Kenji; Yamamoto, Noriyuki; Shigetomi, Toshio

    2010-01-01

    Superselective intra-arterial chemotherapy via a superficial temporal artery has become feasible for daily concurrent radiotherapy and chemotherapy in patients with oral cancer. In this study, histopathological effects on metastatic cervical lymph nodes in cases of advanced oral cancer using superselective intra-arterial chemoradiotherapy were evaluated. Thirty-seven oral cancer patients with cervical lymph node metastasis were treated with preoperative chemoradiotherapy using superselective intra-arterial infusion via the superficial temporal artery. The treatment consisted of superselective intra-arterial infusions (docetaxel, total 60 mg/m 2 ; cisplatin, total 100-150 mg/m 2 ) and concurrent radiotherapy (total 40-60 Gy) for 4-6 weeks, followed by surgery. In cases in which the catheter was inserted into the facial artery, grade III or IV (Oboshi-Shimosato classification) in the cervical lymph node metastasis was obtained in 20 (83.3%) of 24 patients. And, forty-six (88.5%) of 52 metastatic lymph nodes showed grade III or IV. This method was an effective regimen for oral cancer with cervical lymph node metastasis. (author)

  3. Emergency aortic valve replacement and Caesarian section in a primigravida with severe aortic stenosis: a case report.

    Science.gov (United States)

    Kochhar, Puneet K; Zutshi, V; Shamsunder, S; Batra, S; Ghosh, P

    2011-01-01

    Congenital bicuspid aortic valve with severe aortic stenosis (AS) is a rare condition (3-6% of patients with congenital heart disease). Pregnancy in these patients carries a high risk of maternal and fetal mortality. With advancing gestational age, these women may develop cardiac failure due to increased cardiorespiratory requirements. When medical therapy proves insufficient, cardiac surgery becomes mandatory to save the patient's life. Balloon valvuloplasty is only palliative treatment, the duration of benefit being only 6 months. Valve replacement is thus recommended. Cardiopulmonary bypass (CPB) surgery with valve replacement has been reported to carry a lower risk of maternal mortality (1.5-13%) but a very high fetal risk (16-40%). This paper reports the case of a 30-year-old primigravida with severe AS with bicuspid aortic valve and pulmonary congestion clinically uncontrolled, in whom CPB surgery and aortic valve replacement was performed as an emergency procedure, along with a lower segment Caesarian section. The outcome of unrelieved severe symptomatic AS in pregnancy is poor. Multidisciplinary management is important to avoid deterioration in cardiac performance in parturients with severe AS. CPB during pregnancy carries a high risk to the fetus. Therefore, open heart surgery during pregnancy should be advised only in extreme emergencies (ie, heart failure refractory to conventional therapy).

  4. Aortic root surgery in Marfan syndrome: Bentall procedure with the composite mechanical valved conduit versus aortic valve reimplantation with Valsalva graft.

    Science.gov (United States)

    Nardi, Paolo; Pellegrino, Antonio; Versaci, Francesco; Mantione, Ludmilla; Polisca, Patrizio; Iorio, Fiore S; Chiariello, Luigi

    2010-09-01

    The aim of the study is to compare mid-term results of Bentall aortic root replacement with composite mechanical valved conduit and aortic valve reimplantation procedure using the Valsalva graft for the treatment of aortic root aneurysm in patients with Marfan syndrome. We retrospectively compared data of 23 patients (mean age 38 + or - 14 years) who had undergone the Bentall procedure (group B) to those of 24 patients (mean age 36 + or - 12 years) who had undergone aortic valve reimplantation (group R) during a 14-year period. Follow-up (mean duration 65 + or - 44 months) was 100% complete. There were no operative deaths in either group. In group B, as compared with group R, preoperative aortic insufficiency (3.2 + or - 1.1/4 vs. 1.7 + or - 1.4/4, P Marfan patients, the Bentall procedure is associated with excellent mid-term outcome. The reimplantation technique, adopted for less dilated aortas, provides similarly satisfactory results. The Valsalva graft seems, with time, to allow a stable aortic valve function.

  5. A quarter of a century of experience with aortic valve-sparing operations.

    Science.gov (United States)

    David, Tirone E; Feindel, Christopher M; David, Carolyn M; Manlhiot, Cedric

    2014-09-01

    To examine the late outcomes of aortic valve-sparing operations to treat patients with aortic root aneurysm with and without aortic insufficiency (AI) in a cohort of patients followed up prospectively since 1988. A total of 371 consecutive patients had undergone aortic valve-sparing surgery (mean age, 47 ± 15 years; 78% men) from 1988 through 2010. In addition to the aortic root aneurysm, 47% had moderate or severe AI, 35.5% had Marfan syndrome, 12.1% had type A aortic dissection, 9.2% had bicuspid aortic valve, 8.4% had mitral insufficiency, 16.1% had aortic arch aneurysm, and 10.2% had coronary artery disease. Reimplantation of the aortic valve was used in 296 patients and remodeling of the aortic root in 75. Cusp repair by plication of the free margin along the nodule of Arantius was used in 36.6% of patients, and reinforcement of the free margin with a double layer of fine Gore-Tex suture in 24.2%. The patients were followed up prospectively with images of the aortic root for a median follow-up of 8.9 ± 5.2 years. A total of 4 operative and 39 late deaths occurred. Survival at 18 years was 76.8% ± 4.31%, lower than that for the general population matched for age and gender. Age, type A aortic dissection, impaired ventricular function, and preoperative AI were associated with increased mortality on multivariable analysis. Reoperations on the aortic valve were performed in 8 patients for recurrent AI and in 2 for infective endocarditis. Freedom from reoperation on the aortic valve at 18 years was 94.8% ± 2.0%. No predictors of the need for reoperation were found on multivariable analysis. Eighteen patients developed AI greater than mild. Freedom from AI greater than mild at 18 years was 78.0% ± 4.8%. No predictors of recurrent AI were identified on multivariable analysis. Aortic valve-sparing operations continue to provide excellent clinical outcomes, although a slow but progressive deterioration of aortic valve function seems to occur during the first 2

  6. Pre-operative and intra-operative detection of axillary lymph node metastases in 108 patients with invasive lobular breast cancer undergoing mastectomy.

    Science.gov (United States)

    Novak, Jerica; Besic, Nikola; Dzodic, Radan; Gazic, Barbara; Vogrin, Andrej

    2018-02-05

    Despite the recent changes in the treatment of the axilla in selected breast cancer patient, positive sentinel lymph node (SLN) in patients undergoing mastectomy still necessitates axillary lymph node dissection (ALND). In invasive lobular carcinoma (ILC), pre-operative detection of the lymph node metastasis may be demanding due to its unique morphology. The aim of this study was to examine the benefit of preoperative axillary ultrasound (AUS), ultrasound-guided fine-needle aspiration biopsy (US-FNAB), and intra-operative imprint cytology (IIC), in order to avoid two-stage axillary surgery in patients with ILC undergoing mastectomy. The object of this study were 102 patients (median age 52, range 34-73 years) with clinically non-suspicious axilla in whom 108 mastectomies were performed after a pre-operative AUS investigation. Whenever a metastasis was detected in a sentinel lymph node, ALND was done. Reports of the pre-operative AUS investigation, US-FNAB, and IIC were compared with definitive histopathological reports of surgical specimens. In 46 cases lymph node metastases were diagnosed. AUS suspicious lymph nodes were found in 29/108 cases and histopathology confirmed metastases in 22/30 cases. US-FNAB was performed in 29 cases with AUS suspicious lymph nodes. Cytology proved metastases in 11/29 cases. Histopathology confirmed metastases in 10/11 cases with only isolated tumor cells found in one case. IIC investigation was performed in 63 cases and in 10/27 cases metastases were confirmed by histopathology. Pre-operative AUS, US-FNAB, and/or IIC investigation enabled ALND during a single surgical procedure in 20/46 patients with metastases in lymph nodes. Pre-operative AUS, US-FNAB, and/or IIC are/is beneficial in patients with ILC planned for mastectomy in order to decrease the number of two stage axillary procedures.

  7. Clinical efficacy of transcatheter aortic valve replacement for severe aortic stenosis in high-risk patients: the PREVAIL JAPAN trial.

    Science.gov (United States)

    Sawa, Yoshiki; Takayama, Morimasa; Mitsudo, Kazuaki; Nanto, Shinsuke; Takanashi, Shuichiro; Komiya, Tatsuhiko; Kuratani, Toru; Tobaru, Tetsuya; Goto, Tsuyoshi

    2015-01-01

    Transcatheter aortic valve replacement (TAVR) is suggested to be less invasive and/or equally effective in comparison to conventional aortic valve replacement for high-risk symptomatic aortic stenosis patients. We herein report the initial results of a pivotal clinical trial of TAVR in Japan (the PREVAIL JAPAN). Sixty-four aortic stenosis patients (mean age 84.3 ± 6.1 years) not suitable for surgery were enrolled at three centers in Japan, with a primary composite endpoint of the 6-month post-procedure improvements in the aortic valve area and New York Heart Association (NYHA) functional classification. A transfemoral approach was used in 37 patients and a transapical approach was used in 27. The device success rate was 91.9 %. After 30 days and 6 months, the rates of mortality from any cause were 8.1 and 11.3 %, respectively. At 6 months, symptomatic stroke was found in 3.1 % of the patients, and silent infarction in 7.8 %. The aortic valve area and mean pressure gradient were significantly improved over time with both approaches (p < 0.001). At 6 months, the NYHA functional classification based on a conventional physician's assessment was improved in 87.9 % of the patients. We found results that were equivalent to those in other major TAVR trials, such as an acceptable 30-day survival (91.9 %), suggesting that balloon-expandable TAVR is effective for small Japanese AS patients classified as high-risk or inoperable.

  8. N-terminal pro-B-type natriuretic peptide measurement is useful in predicting left ventricular hypertrophy regression after aortic valve replacement in patients with severe aortic stenosis.

    Science.gov (United States)

    Lee, Mirae; Choi, Jin-Oh; Park, Sung-Ji; Kim, Eun Young; Park, PyoWon; Oh, Jae K; Jeon, Eun-Seok

    2015-01-01

    The predictive factors for early left ventricular hypertrophy (LVH) regression after aortic valve replacement (AVR) have not been fully elucidated. This study was conducted to investigate which preoperative parameters predict early LVH regression after AVR. 87 consecutive patients who underwent AVR due to isolated severe aortic stenosis (AS) were analysed. Patients with ejection fraction regression of LVH at the midterm follow-up was determined. In multivariate analysis, including preoperative echocardiographic parameters, only E/e' ratio was associated with midterm LVH regression (OR 1.11, 95% CI 1.01 to 1.22; p=0.035). When preoperative NT-proBNP was added to the analysis, logNT-proBNP was found to be the single significant predictor of midterm LVH regression (OR 2.00, 95% CI 1.08 to 3.71; p=0.028). By receiver operating characteristic curve analysis, a cut-off value of 440 pg/mL for NT-proBNP yielded a sensitivity of 72% and a specificity of 77% for the prediction of LVH regression after AVR. Preoperative NT-proBNP was an independent predictor for early LVH regression after AVR in patients with isolated severe AS.

  9. Three-year hemodynamic performance, left ventricular mass regression, and prosthetic-patient mismatch after rapid deployment aortic valve replacement in 287 patients.

    Science.gov (United States)

    Haverich, Axel; Wahlers, Thorsten C; Borger, Michael A; Shrestha, Malakh; Kocher, Alfred A; Walther, Thomas; Roth, Matthias; Misfeld, Martin; Mohr, Friedrich W; Kempfert, Joerg; Dohmen, Pascal M; Schmitz, Christoph; Rahmanian, Parwis; Wiedemann, Dominik; Duhay, Francis G; Laufer, Günther

    2014-12-01

    Superior aortic valve hemodynamic performance can accelerate left ventricular mass regression and enhance survival and functional status after surgical aortic valve replacement. This can be achieved by rapid deployment aortic valve replacement using a subannular balloon-expandable stent frame, which functionally widens and reshapes the left ventricular outflow tract, to ensure a larger effective orifice area compared with conventional surgical valves. We report the intermediate-term follow-up data from a large series of patients enrolled in the Surgical Treatment of Aortic Stenosis With a Next Generation Surgical Aortic Valve (TRITON) trial. In a prospective, multicenter (6 European hospitals), single-arm study, 287 patients with aortic stenosis underwent rapid deployment aortic valve replacement using a stented trileaflet bovine pericardial bioprosthesis. Core laboratory echocardiography was performed at baseline, discharge, and 3 months, 1 year, and 3 years after rapid deployment aortic valve replacement. The mean patient age was 75.7 ± 6.7 years (range, 45-93; 49.1% women). The mean aortic valve gradient significantly decreased from discharge to 3 years of follow-up. The mean effective orifice area remained stable from discharge to 3 years. At 1 year, the left ventricular mass index had decreased by 14% (P replacement using a subannular balloon-expandable stent frame demonstrated excellent hemodynamic performance and significant left ventricular mass regression. With continued follow-up, future studies will establish whether these favorable structural changes correlate with improvement in long-term survival and functional status. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  10. High-risk Trans-Catheter Aortic Valve Replacement in a Failed Freestyle Valve with Low Coronary Height: A Case Report.

    Science.gov (United States)

    Karimi, Ashkan; Pourafshar, Negiin; Dibu, George; Beaver, Thomas M; Bavry, Anthony A

    2017-06-01

    A 55-year-old male with a history of two prior cardiac surgeries presented with decompensated heart failure due to severe bioprosthetic aortic valve insufficiency. A third operation was viewed prohibitively high risk and valve-in-valve trans-catheter aortic valve replacement was considered. There were however several high-risk features and technically challenging aspects including low coronary ostia height, poor visualization of the aortic sinuses, and difficulty in identification of the coplanar view due to severe aortic insufficiency, and a highly mobile aortic valve mass. After meticulous peri-procedural planning, trans-catheter aortic valve replacement was carried out with a SAPIEN 3 balloon-expandable valve without any complication. Strategies undertaken to navigate the technically challenging aspects of the case are discussed.

  11. Simultaneous rota-stenting and transcatheter aortic valve implantation for patients with heavily calcified coronary stenosis and aortic stenosis

    Directory of Open Access Journals (Sweden)

    Yung-Tsai Lee

    2016-09-01

    Full Text Available Given that coronary artery disease (CAD in octogenarians undergoing transcatheter aortic valve implantation (TAVI often presents with more complex lesions and extensive calcification, rotational atherectomy (RA may be needed in some cases before stenting. However, data regarding the feasibility and safety of simultaneous RA during TAVI using the Medtronic CoreValve (MCV; Medtronic, Minneapolis, MN, USA system are lacking. Three out of 107 (2.8% patients (2 females, average age 85.6 years, mean aortic valve area 0.5 cm2, mean left ventricular ejection fraction 39%, mean Logistic EuroScore 70%, with complex, heavily calcified coronary stenosis, and severe valvular aortic stenosis (AS were treated with TAVI and RA due to high surgical risk. After balloon valvuloplasty, all coronary lesions were successfully treated with RA and stenting, immediately followed by transfemoral TAVI with a self-expandable MCV. Our data suggested that in the very elderly patients with severe and heavily calcified CAD and AS who were turned down for cardiac surgery, RA and stenting followed by TAVI may be performed successfully in a combined, single-stage procedure.

  12. Preoperative evaluation of the artery of adamkiewicz by MR angiography and CT angiography in patients with a thoracic aortic aneurysm

    International Nuclear Information System (INIS)

    Niinuma, Hiroyuki; Ohira, Atsushi; Makita, Shinji; Moriai, Yoshiteru; Hiramori, Katsuhiko; Yoshioka, Kunihiro; Nakajima, Takayuki; Kawazoe, Kohei

    2002-01-01

    Paraplegia is known as an extremely serious and important complication of surgical repair in patients with a thoraco-abdominal aortic aneurysm. It is important to evaluate the artery of Adamkiewicz (AdA) before surgical repair to prevent paraplegia. But the AdA is difficult to visualize by the invasive and hazardous, conventional selective angiography. The aim of this study was to visualize AdA by MR angiography (MRA) and CT angiography (CTA). Twenty-one consecutive patients with a thoracic aortic aneurysm underwent both gadolinium-enhanced, three-dimensional MRA and CTA using multislice helical CT. The AdA was successfully visualized in 15 of the 21 patients (71.4%) by MRA, and in 17 of those 21 patients (80.9%) by CTA. Its continuity was depicted in 12 of 15 patients (80%) by MRA, and in 9 of 17 patients (47%) by CTA. AdA was visualized at 85.7% by MRA or CTA, respectively. This study shows that CTA is a much more sensitive method to detect AdA than MRA. On the other hand, MRA is better to evaluate the continuity of AdA from the descending aorta to the anterior spinal artery, than CTA. Therefore, MRA and CTA are both useful for a preoperative evaluation of AdA and its detailed vascular anatomy from the aorta to the anterior spinal artery. (author)

  13. Comparative in vivo analysis of the role of the adventitia and the endothelium on arterial mechanical function: relevance for aortic counterpulsation.

    Science.gov (United States)

    Bia, Daniel; Zócalo, Yanina; Wray, Sandra; Cabrera-Fischer, Edmundo I

    2017-06-09

    The comparative effect of the intimal and adventitial layers on arterial biomechanics control, in basal and altered conditions, remains to be elucidated. This study aimed (1) to characterize the arterial conduit (CF) and buffering (distensibility) function of the iliac arteries in in vivo animals, in which the intimal and adventitial layers were removed; (2) to determine the effects of intra-aortic ballon pumping (IABP) on simultaneously de-adventitialized (DA) and de-endothelialized (DE) iliac arteries before and after induced heart failure. Pressure and diameter signals were measured in the iliac arteries of sheep (n = 7) in which the adventitial and intima layer were removed. Intra-aortic balloon pump (IABP) assistance was used in a control state and after heart failure induction. Both DE and DA determined significant changes in arterial diameter, distensibility and CF. Changes were higher after DA than after DE in terms of distensibility and CF (p<0.05). DA followed by DE (DA + DE) showed significant increases in arterial diameter and CF, accompanied by a decrease in distensibility (p<0.05) with respect to intact arteries. Heart failure induction caused significant hemodynamic changes without modifying the already impaired local biomechanical parameters. Nonsignificant improvements in the biomechanical parameters of DA + DE iliac arteries were observed during IABP before and after heart failure induction. Biomechanical changes caused by DA of iliac arteries were more important than those observed after DE. The DA + DE arteries showed significant differences with respect to intact arteries and with DA or DE arteries. IABP-related effects on arterial mechanics were absent in DA + DE arteries.

  14. Long-term outcomes of aortic root operations for Marfan syndrome: A comparison of Bentall versus aortic valve-sparing procedures.

    Science.gov (United States)

    Price, Joel; Magruder, J Trent; Young, Allen; Grimm, Joshua C; Patel, Nishant D; Alejo, Diane; Dietz, Harry C; Vricella, Luca A; Cameron, Duke E

    2016-02-01

    Prophylactic aortic root replacement improves survival in patients with Marfan syndrome with aortic root aneurysms, but the optimal procedure remains undefined. Adult patients with Marfan syndrome who had Bentall or aortic valve-sparing root replacement (VSRR) procedures between 1997 and 2013 were identified. Comprehensive follow-up information was obtained from hospital charts and telephone contact. One hundred sixty-five adult patients with Marfan syndrome (aged > 20 years) had either VSRR (n = 98; 69 reimplantation, 29 remodeling) or Bentall (n = 67) procedures. Patients undergoing Bentall procedure were older (median, 37 vs 36 years; P = .03), had larger median preoperative sinus diameter (5.5 cm vs 5.0 cm; P = .003), more aortic dissections (25.4% vs 4.1%; P Marfan syndrome, patients undergoing Bentall and valve-sparing procedures have similar late survival, freedom from root reoperation, and freedom from endocarditis. However, valve-sparing procedures result in significantly fewer thromboembolic and hemorrhagic events. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  15. Diabetes Mellitus Impairs Left Ventricular Mass Regression after Surgical or Transcatheter Aortic Valve Replacement for Severe Aortic Stenosis.

    Science.gov (United States)

    Nakamura, Teruya; Toda, Koichi; Kuratani, Toru; Miyagawa, Shigeru; Yoshikawa, Yasushi; Fukushima, Satsuki; Saito, Shunsuke; Yoshioka, Daisuke; Kashiyama, Noriyuki; Daimon, Takashi; Sawa, Yoshiki

    2016-01-01

    It is well-documented that persistent myocardial hypertrophy in patients with aortic stenosis is related to suboptimal postoperative outcomes after aortic valve replacement. Although diabetes is known to potentially exacerbate myocardial hypertrophy, it has yet to be examined if it affects postoperative left ventricular mass regression (LVMR). A single-centre, retrospective analysis was performed on 183 consecutive patients who underwent either surgical or transcatheter aortic valve replacement between 2010 and May 2013. Patient demographics, postoperative outcomes and echocardiographic data were obtained preoperatively and a year after surgery. There were 42 diabetic and 141 non-diabetic patients. Preoperative characteristics of diabetic patients were statistically similar to those of non-diabetic patients, except for higher prevalence of hyperlipidaemia (p regression analysis demonstrated that diabetes (standardised partial regression coefficient (SPRC)=-0.187, p=0.018), female gender (SPRC=0.245, p=0.026) and age (SPRC=0.203, p=0.018) were associated with poor postoperative LVMR. Patients with diabetes showed suboptimal postoperative LVMR, and the disease was a prognostic factor that was associated with poor LVMR. These findings suggest that diabetes may predispose the particular group of patients to worse postoperative outcomes. Copyright © 2015 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  16. Pilot study of dynamic cine CT angiography for the evaluation of abdominal aortic aneurysms : Implications for endograft treatment

    NARCIS (Netherlands)

    Teutelink, A; Rutten, A; Muhs, BE; Olree, M; van Herwaarden, JA; de Vos, AM; Prokop, M; Moll, FL; Verhagen, HJM

    Purpose: To utilize 40-slice electrocardiographically (ECG)-gated cine computed tomographic angiography (CTA) to characterize normal aortic motion during the cardiac cycle at relevant anatomical landmarks in preoperative abdominal aortic aneurysm (AAA) patients. Methods: In 10 consecutive

  17. Three-year-old child with middle aortic syndrome treated by endovascular stent implantation.

    Science.gov (United States)

    Moszura, Tomasz; Goreczny, Sebastian; Dryzek, Pawel; Niwald, Marek

    2013-04-01

    Middle aortic syndrome (MAS) is an extremely rare anomaly and represents both a diagnostic and therapeutic challenge, particularly in young children. A case of a 3.5 year-old child with MAS and arterial hypertension is reported, where owing to the patient's young age and the length of the hypoplastic aortic segment, surgical correction with end-to-end anastomosis was not feasible. Instead of palliative bypass grafting between the thoracic and abdominal aorta, successful percutaneous balloon angioplasty and stenting of the lesion was performed with the assistance of three-dimensional rotational angiography.

  18. Different transcatheter strategies for aortic coarctation associated with patent ductus arteriosus

    Directory of Open Access Journals (Sweden)

    Anil Kumar Singhi

    2012-07-01

    Conclusions: In coarctation with patent ductus arteriosus associated with good sized aortic isthmus, closure of duct with duct occluder device and balloon aortoplasty would correct the lesions. If there is isthmic hypoplasia, device closure of the duct and stenting of the coarctation is needed. Covered stent is a reasonable alternative only in presence of non dilated descending aorta.

  19. Sonography of intrathyroid parathyroid adenomas: Are there distinctive features that allow for preoperative identification?

    International Nuclear Information System (INIS)

    Heller, Matthew T.; Yip, Linwah; Tublin, Mitchell E.

    2013-01-01

    Objective: The purpose of our study was to determine if intra-thyroid parathyroid adenomas can be accurately identified by applying proposed criteria to preoperative ultrasound examinations in patients with primary hyperparathyroidism. Materials/methods: Fifty-three patients with pathology proven intra-thyroid parathyroid adenomas and pre-operative ultrasounds were identified from a surgical database for a blinded, retrospective review. A contemporary, age-matched cohort of 54 patients with extra-thyroid parathyroid adenomas was identified as a control. A total of 64 patients within these cohorts had co-existing thyroid nodules. Proposed ultrasound criteria for identifying a parathyroid adenoma included solid composition, profound hypoechogenicity, and presence of a feeding polar vessel. Parathyroid adenomas were classified as extra-thyroid or intra-thyroid (partial or complete) based on their relationship with the thyroid gland during ultrasound evaluation and results were compared to surgical and histopathology reports as the gold standard. The results from the blinded, retrospective review during which the proposed, specific ultrasound criteria were applied were compared to the initial, pre-operative reports during which the proposed criteria were not applied. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of the blinded, retrospective review and initial, pre-operative reports were calculated. Additionally, in patients with co-existing thyroid nodules, an attempt was made to differentiate parathyroid adenomas from the thyroid nodules. Results: Application of the proposed ultrasound criteria during blinded retrospective review yielded a sensitivity and specificity for detecting intra-thyroid parathyroid adenomas of 76% and 92%, respectively. The sensitivity and specificity of ultrasound for detecting intra-thyroid parathyroid adenomas on the initial reports was 29% and 95%, respectively. The sensitivity and

  20. Transcatheter aortic valve implantation for failing surgical aortic bioprosthetic valve: from concept to clinical application and evaluation (part 2).

    Science.gov (United States)

    Piazza, Nicolo; Bleiziffer, Sabine; Brockmann, Gernot; Hendrick, Ruge; Deutsch, Marcus-André; Opitz, Anke; Mazzitelli, Domenico; Tassani-Prell, Peter; Schreiber, Christian; Lange, Rüdiger

    2011-07-01

    This study sought to review the acute procedural outcomes of patients who underwent transcatheter aortic valve (TAV)-in-surgical aortic valve (SAV) implantation at the German Heart Center, Munich, and to summarize the existing literature on TAV-in-SAV implantation (n = 47). There are several case reports and small case series describing transcatheter aortic valve implantation for a failing surgical aortic valve bioprosthesis (TAV-in-SAV implantation). From January 2007 to March 2011, 20 out of 556 patients underwent a TAV-in-SAV implantation at the German Heart Center Munich. Baseline characteristics and clinical outcome data were prospectively entered into a dedicated database. The mean patient age was 75 ± 13 years, and the mean logistic European System for Cardiac Operative Risk Evaluation and Society of Thoracic Surgeons' Risk Model scores were 27 ± 13% and 7 ± 4%, respectively. Of the 20 patients, 14 had stented and 6 had stentless surgical bioprostheses. Most cases (12 of 20) were performed via the transapical route using a 23-mm Edwards Sapien prosthesis (Edwards Lifesciences, Irvine, California). Successful implantation of a TAV in a SAV with the patient leaving the catheterization laboratory alive was achieved in 18 of 20 patients. The mean transaortic valve gradient was 20.0 ± 7.5 mm Hg. None-to-trivial, mild, and mild-to-moderate paravalvular aortic regurgitation was observed in 10, 6, and 2 patients, respectively. We experienced 1 intraprocedural death following pre-implant balloon aortic valvuloplasty ("stone heart") and 2 further in-hospital deaths due to myocardial infarction. TAV-in-SAV implantation is a safe and feasible treatment for high-risk patients with failing aortic bioprosthetic valves and should be considered as part of the armamentarium in the treatment of aortic bioprosthetic valve failure. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  1. Aortic stenosis: From diagnosis to optimal treatment

    Directory of Open Access Journals (Sweden)

    Tavčiovski Dragan

    2008-01-01

    Full Text Available Aortic stenosis is the most frequent valvular heart disease. Aortic sclerosis is the first characteristic lesion of the cusps, which is considered today as the process similar to atherosclerosis. Progression of the disease is an active process leading to forming of bone matrix and heavily calcified stiff cusps by inflammatory cells and osteopontin. It is a chronic, progressive disease which can remain asymptomatic for a long time even in the presence of severe aortic stenosis. Proper physical examination remains an essential diagnostic tool in aortic stenosis. Recognition of characteristic systolic murmur draws attention and guides further diagnosis in the right direction. Doppler echocardiography is an ideal tool to confirm diagnosis. It is well known that exercise tests help in stratification risk of asymptomatic aortic stenosis. Serial measurements of brain natriuretic peptide during a follow-up period may help to identify the optimal time for surgery. Heart catheterization is mostly restricted to preoperative evaluation of coronary arteries rather than to evaluation of the valve lesion itself. Currently, there is no ideal medical treatment for slowing down the disease progression. The first results about the effect of ACE inhibitors and statins in aortic sclerosis and stenosis are encouraging, but there is still not enough evidence. Onset symptoms based on current ACC/AHA/ESC recommendations are I class indication for aortic valve replacement. Aortic valve can be replaced with a biological or prosthetic valve. There is a possibility of percutaneous aortic valve implantation and transapical operation for patients that are contraindicated for standard cardiac surgery.

  2. More than just a urinary catheter — Haemorrhage control by using a Foley catheter in a penetrating aortic root injury

    Directory of Open Access Journals (Sweden)

    Adel Elmoghrabi

    2016-08-01

    Full Text Available The prevalence of great vessel injuries in thoracic trauma is reported at 0.3–10%, predominantly due to a penetrating mechanism. Thoracic aortic injuries, more specifically those within proximity of the aortic root are challenging to manage and unceasing bleeding hampers adequate visualisation for performing repair. We report a case of a 31-year-old male that presented to the emergency department 1 h after sustaining a stab wound injury within proximity of the left upper sternal border. Vital signs were stable on presentation. Physical examination revealed a 1.5 cm laceration in the 3rd intercostal space. Chest X-ray revealed a small left pneumothorax, FAST scan was negative, and CT of the chest revealed left sided haemopneumothorax and haemopericardium. The patient was emergently transferred to the operating room where median thoracotomy was performed. A significant amount of bleeding was observed originating from a 1 cm laceration of the aortic root. Bleeding was controlled using a Foley catheter after unsuccessful attempts of digital compression, and the laceration was repaired using pledgeted sutures. Postoperative echocardiography and CT scan of the chest revealed normal cardiac functions with resolution of haemopericardium and haemopneumothorax, and the patient was discharged in a stable condition. High index of suspicion should be maintained for injury to the great vessels in patients with penetrating chest injuries, despite apparent haemodynamic stability. In this case, balloon tamponade using a Foley catheter served as a quick and simple technique that resulted in an almost bloodless field, facilitating adequate visualisation for definitive repair. Although the use of this technique has been previously described, this report serves as a reminder that a Foley catheter can be successfully used for balloon catheter tamponade in injuries to the aortic root. Keywords: Aortic root, Injury, Foley's catheter, Balloon catheter, Aorta

  3. Global Strain in Severe Aortic Valve Stenosis

    DEFF Research Database (Denmark)

    Dahl, Jordi S; Videbæk, Lars; Poulsen, Mikael K

    2012-01-01

    Score, history with ischemic heart disease and ejection fraction. CONCLUSIONS: -In patients with symptomatic severe aortic stenosis undergoing AVR reduced GLS provides important prognostic information beyond standard risk factors. Clinical Trial Registration-URL: http://www.clinicaltrial.gov. Unique identifier......BACKGROUND: -Global longitudinal systolic strain (GLS) is often reduced in aortic stenosis despite normal ejection fraction. The importance of reduced preoperative GLS on long-term outcome after aortic valve replacement (AVR) is unknown. METHODS AND RESULTS: -A total of 125 patients with severe...... and mortality. In a stepwise cox model with forward selection GLS was the sole independent predictor HR=1.13 (95% confidence interval 1.02-1.25), p=0.04. Comparing the overall log likelihood χ(2) of the predictive power of the multivariable model containing GLS was statistically superior to models based on Euro...

  4. Systematic Design of a Magnetically Levitated Brushless DC Motor for a Reversible Rotary Intra-Aortic Blood Pump.

    Science.gov (United States)

    Wang, Yaxin; Logan, Thomas G; Smith, P Alex; Hsu, Po-Lin; Cohn, William E; Xu, Liping; McMahon, Richard A

    2017-10-01

    The IntraVAD is a miniature intra-aortic ventricular assist device (VAD) designed to work in series with the compromised left ventricle. A reverse-rotation control (RRc) mode has been developed to increase myocardial perfusion and reduce ventricular volume. The RRc mode includes forward rotation in systole and reverse rotation in diastole, which requires the IntraVAD to periodically reverse its rotational direction in synchrony with the cardiac cycle. This periodic reversal leads to changes in pressure force over the impeller, which makes the entire system less stable. To eliminate the mechanical wear of a contact bearing and provide active control over the axial position of the rotor, a miniature magnetically levitated bearing (i.e., the PM-Coil module) composed of two concentric permanent magnetic (PM) rings and a pair of coils-one on each side-was proposed to provide passive radial and active axial rotor stabilization. In the early design stage, the numerical finite element method (FEM) was used to optimize the geometry of the brushless DC (BLDC) motor and the maglev module, but constructing a new model each time certain design parameters were adjusted required substantial computation time. Because the design criteria for the module had to be modified to account for the magnetic force produced by the motor and for the hemodynamic changes associated with pump operation, a simplified analytic expression was derived for the expected magnetic forces. Suitable bearings could then be designed capable of overcoming these forces without repeating the complicated FEM simulation for the motor. Using this method at the initial design stage can inform the design of the miniature maglev BLDC motor for the proposed pulsatile axial-flow VAD. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  5. Thoracic aortic coarctation: MR evaluation and follow-up

    International Nuclear Information System (INIS)

    Papavero, R.; Kastler, B.; Clair, C.; Livolsi, A.; Papavero, R.; Site, O.; Kastler, B.; Clair, C.; Litzler, J.F.; Delabrousse, E.; Scheneider, P.; Bernard, Y.

    2001-01-01

    Purpose: Report our experience in the evaluation and follow-up of thoracic aortic coarctation with MRI and describe its role to estimate trans-stenotic flow. Material and methods: 43 MR examinations were performed in 30 patients (age range 15 days to 73 years) referred to our institution in the last 7 years. Results: MRI visualized the ascending, horizontal and descending portions of the aorta and the supra-aortic vessels in 42/43 patients. MRI clearly identified preoperatively an aortic coarctation in 11/12 cases confirmed by surgery. Postoperatively MRI depicted 4 restenosis and one aneurysm. In 5 patients MRI demonstrated pseudo-coarctation. A significant correlation was established between the maximal trans-stenotic pressure gradient when measured by Doppler US or angiography and the size of the signal void measured on cine-MR images (r=0.72; p<0.01). Conclusion: MRI is a reliable non invasive investigation method for the diagnosis and semi-quantitative evaluation of aortic coarctation particularly when colour Doppler US is not satisfactory. (authors)

  6. Selective Aortic Arch and Root Replacement in Repair of Acute Type A Aortic Dissection.

    Science.gov (United States)

    Fleischman, Fernando; Elsayed, Ramsey S; Cohen, Robbin G; Tatum, James M; Kumar, S Ram; Kazerouni, Kayvan; Mack, Wendy J; Barr, Mark L; Cunningham, Mark J; Hackmann, Amy E; Baker, Craig J; Starnes, Vaughn A; Bowdish, Michael E

    2018-02-01

    Controversy exists regarding the optimal extent of repair for type A aortic dissection. Our approach is to replace the ascending aorta, and only replace the aortic root or arch when intimal tears are present in those areas. We examined intermediate outcomes with this approach to acute type A aortic dissection repair. Between March 2005 and October 2016, 195 patients underwent repair of acute type A aortic dissection. Repair was categorized by site of proximal and distal anastomosis and extent of repair. Mean follow-up was 31.0 ± 30.9 months. Kaplan-Meier analysis was used to assess survival. Multiple variable Cox proportional hazards modeling was utilized to identify factors associated with overall mortality. Overall survival was 85.1%, 83.9%, 79.1%, and 74.4% at 6, 12, 36, and 60 months, respectively. Eight patients required reintervention. The cumulative incidence of aortic reintervention at 1 year with death as a competing outcome was 3.95%. Multiple variable regression analysis identified factors such as age, preoperative renal failure, concomitant thoracic endograft, postoperative myocardial infarction and sepsis, and need for extracorporeal membrane oxygenation as predictive of overall mortality. Neither proximal or distal extent of repair, nor need for reintervention affected overall survival (proximal: hazard ratio 1.63, 95% confidence interval: 0.75 to 3.51, p = 0.22; distal: hazard ratio 1.12, 95% confidence interval: 0.43 to 2.97, p = 0.81; reintervention: hazard ratio 0.03, 95% confidence interval: 0.002 to 0.490, p < 0.01). A selective approach to root and arch repair in acute type A aortic dissection is safe. If aortic reintervention is needed, survival does not appear to be affected. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Pulmonary Venous Diastolic Flow Reversal and Flash Pulmonary Edema During Management of Ongoing Myocardial Ischemia with Intraaortic Balloon Pump.

    Science.gov (United States)

    Murray, Davoy; Peng, Yong G

    2015-10-15

    A 65-year-old man was admitted for acute coronary syndrome with depressed left ventricular function and moderate aortic regurgitation. He was managed with an intraaortic balloon pump for circulatory support before coronary artery bypass grafting and subsequently developed flash pulmonary edema with an associated rare finding of diastolic pulmonary venous flow reversal. In this report, we provide a review of intraaortic balloon pump use in current clinical practice and elaborate on the pathophysiology of an uncommon pulmonary venous flow pattern found in our patient.

  8. Satisfactory short-term outcomes of the STABILISE technique for type B aortic dissection.

    Science.gov (United States)

    Melissano, Germano; Bertoglio, Luca; Rinaldi, Enrico; Mascia, Daniele; Kahlberg, Andrea; Loschi, Diletta; De Luca, Monica; Monaco, Fabrizio; Chiesa, Roberto

    2018-03-29

    The aim of this study was to evaluate the perioperative and short-term results in a cohort of patients treated during the last year at our institution with the stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair (STABILISE) technique for acute complicated aortic dissection. Between June 2016 and June 2017, 10 patients (all male; mean age, 62.6 ± 7.4 years) received treatment for acute complicated aortic dissection with the STABILISE technique. After a standard provisional extension to induce complete attachment procedure using the commercially available endovascular dissection system (Cook Medical, Bloomington, Ind), the distal stent graft area and the bare stent area were ballooned to completely exclude the thoracic false lumen (FL) and to obtain a single-channeled abdominal aorta. Computed tomography was routinely performed within the first postoperative week before discharge and then at 3 months, at 6 months, and yearly thereafter. The technical and clinical success rates were analyzed. The 30-day technical and clinical success rates were 100%, with complete thrombosis of the thoracic FL and no type I endoleak. Malperfusion was resolved in all cases. No aortic ruptures were recorded, and no open conversion was required. One case of delayed spinal cord ischemia fully resolved within the discharge period. Predischarge computed tomography showed complete thrombosis of the thoracic FL in all cases. In two cases, some degree of patency of the abdominal FL was observed. At short-term follow-up, the overall aortic diameters remained stable with no further dilation. The STABILISE technique was safe and feasible in this cohort of patients, with complete thrombosis of the thoracic FL and creation of a single-channeled aorta in most cases. Further studies are needed to ascertain the long-term behavior of the treated aorta. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  9. Left atrial volume index as a predictor for persistent left ventricular dysfunction after aortic valve surgery in patients with chronic aortic regurgitation: the role of early postoperative echocardiography.

    Science.gov (United States)

    Cho, In-Jeong; Chang, Hyuk-Jae; Hong, Geu-Ru; Heo, Ran; Sung, Ji Min; Lee, Sang-Eun; Chang, Byung-Chul; Shim, Chi Young; Ha, Jong-Won; Chung, Namsik

    2015-06-01

    This study aimed to explore whether echocardiographic measurements during the early postoperative period can predict persistent left ventricular systolic dysfunction (LVSD) after aortic valve surgery in patients with chronic aortic regurgitation (AR). We prospectively recruited 54 patients (59 ± 12 years) with isolated chronic severe AR who subsequently underwent aortic valve surgery. Standard transthoracic echocardiography was performed before the operation, during the early postoperative period (≤2 weeks), and then 1 year after the surgery. Twelve patients with preoperative LVSD demonstrated LVSD at early after the surgery. Of the 42 patients without LVSD at preoperative echocardiography, 15 patients (36%) developed early postoperative LVSD after surgical correction. All 27 patients without LVSD at early postoperative echocardiography maintained LV function at 1 year after surgery. In the other 27 patients with postoperative LVSD, 17 patients recovered from LVSD and 10 patients did not at 1 year after surgery. Multiple logistic analysis demonstrated that postoperative left atrial volume index (LAVI) was the only independent predictor for persistent LVSD at 1 year after surgery in patients with postoperative LVSD (OR 1.180, 95% CI, 1.003-1.390, P = 0.046). The optimal LAVI cutoff value (>34.9 mL/m(2) ) had a sensitivity of 80% and a specificity of 88% for the prediction of persistent LVSD. Prevalence of early postoperative LVSD was relatively high, even in the patients without LVSD at preoperative echocardiography. Postoperative LAVI could be useful to predict persistent LVSD after aortic valve surgery in patients with early postoperative LVSD. © 2014, Wiley Periodicals, Inc.

  10. Diagnostic performance of whole brain volume perfusion CT in intra-axial brain tumors: Preoperative classification accuracy and histopathologic correlation

    International Nuclear Information System (INIS)

    Xyda, Argyro; Haberland, Ulrike; Klotz, Ernst; Jung, Klaus; Bock, Hans Christoph; Schramm, Ramona; Knauth, Michael; Schramm, Peter

    2012-01-01

    Background: To evaluate the preoperative diagnostic power and classification accuracy of perfusion parameters derived from whole brain volume perfusion CT (VPCT) in patients with cerebral tumors. Methods: Sixty-three patients (31 male, 32 female; mean age 55.6 ± 13.9 years), with MRI findings suspected of cerebral lesions, underwent VPCT. Two readers independently evaluated VPCT data. Volumes of interest (VOIs) were marked circumscript around the tumor according to maximum intensity projection volumes, and then mapped automatically onto the cerebral blood volume (CBV), flow (CBF) and permeability Ktrans perfusion datasets. A second VOI was placed in the contra lateral cortex, as control. Correlations among perfusion values, tumor grade, cerebral hemisphere and VOIs were evaluated. Moreover, the diagnostic power of VPCT parameters, by means of positive and negative predictive value, was analyzed. Results: Our cohort included 32 high-grade gliomas WHO III/IV, 18 low-grade I/II, 6 primary cerebral lymphomas, 4 metastases and 3 tumor-like lesions. Ktrans demonstrated the highest sensitivity, specificity and positive predictive value, with a cut-off point of 2.21 mL/100 mL/min, for both the comparisons between high-grade versus low-grade and low-grade versus primary cerebral lymphomas. However, for the differentiation between high-grade and primary cerebral lymphomas, CBF and CBV proved to have 100% specificity and 100% positive predictive value, identifying preoperatively all the histopathologically proven high-grade gliomas. Conclusion: Volumetric perfusion data enable the hemodynamic assessment of the entire tumor extent and provide a method of preoperative differentiation among intra-axial cerebral tumors with promising diagnostic accuracy.

  11. The Infant with Aortic Arch Hypoplasia and Small Left Heart Structures: Echocardiographic Indices of Mitral and Aortic Hypoplasia Predicting Successful Biventricular Repair.

    Science.gov (United States)

    Plymale, Jennifer M; Frommelt, Peter C; Nugent, Melodee; Simpson, Pippa; Tweddell, James S; Shillingford, Amanda J

    2017-08-01

    In infants with aortic arch hypoplasia and small left-sided cardiac structures, successful biventricular repair is dependent on the adequacy of the left-sided structures. Defining accurate thresholds of echocardiographic indices predictive of successful biventricular repair is paramount to achieving optimal outcomes. We sought to identify pre-operative echocardiographic indices of left heart size that predict intervention-free survival in infants with small left heart structures undergoing primary aortic arch repair to establish biventricular circulation (BVC). Infants ≤2 months undergoing aortic arch repair from 1999 to 2010 with aortic and/or mitral valve hypoplasia, (Z-score ≤-2) were included. Pre-operative and follow-up echocardiograms were reviewed. Primary outcome was successful biventricular circulation (BVC), defined as freedom from death, transplant, or single ventricular conversion at 1 year. Need for catheter based or surgical re-intervention (RI), valve annular growth, and significant late aortic or mitral valve obstruction were additional outcomes. Fifty one of 73 subjects (79%) had successful BVC and were free of RI at 1 year. Seven subjects failed BVC; four of those died. The overall 1 year survival for the cohort was 95%. Fifteen subjects underwent a RI but maintained BVC. In univariate analysis, larger transverse aorta (p = 0.006) and aortic valve (p = 0.02) predicted successful BVC without RI. In CART analysis, the combination of mitral valve (MV) to tricuspid valve (TV) ratio ≤0.66 with an aortic valve (AV) annulus Z-score ≤-3 had the greatest power to predict BVC failure (sensitivity 71%, specificity 94%). In those with successful BVC, the combination of both AV and MV Z-score ≤-2.5 increased the odds of RI (OR 3.8; CI 1.3-11.4). Follow-up of non-RI subjects revealed improvement in AV and MV Z-score (median AV annulus changed over time from -2.34 to 0.04 (p indices. In this complex population, 1 year survival is high, but

  12. Postoperative Reverse Remodeling and Symptomatic Improvement in Normal-Flow Low-Gradient Aortic Stenosis After Aortic Valve Replacement.

    Science.gov (United States)

    Carter-Storch, Rasmus; Møller, Jacob E; Christensen, Nicolaj L; Irmukhadenov, Akhmadjon; Rasmussen, Lars M; Pecini, Redi; Øvrehus, Kristian A; Søndergård, Eva V; Marcussen, Niels; Dahl, Jordi S

    2017-12-01

    Severe aortic stenosis (AS) most often presents with reduced aortic valve area (gradient (≥40 mm Hg; normal-flow high-gradient AS) or low mean gradient (normal-flow low-gradient [NFLG] AS). The benefit of aortic valve replacement (AVR) among NFLG patients is controversial. We compared the impact of NFLG condition on preoperative left ventricular (LV) remodeling and myocardial fibrosis and postoperative remodeling and symptomatic benefit. Eighty-seven consecutive patients with reduced aortic valve area and normal stroke volume index undergoing AVR underwent echocardiography, magnetic resonance imaging, a 6-minute walk test, and measurement of natriuretic peptides before and 1 year after AVR. Myocardial fibrosis was assessed from magnetic resonance imaging. Patients were stratified as NFLG or normal-flow high-gradient. In total, 33 patients (38%) had NFLG. Before AVR, they were characterized by similar symptom burden but less severe AS measured by aortic valve area index (0.50±0.09 versus 0.40±0.08 cm 2 /m 2 ; P gradient condition independently predicted change in LV mass index. Patients with NFLG had less severe AS and LV remodeling than patients with normal-flow high-gradient. Furthermore, NFLG patients experienced less reverse remodeling but the same symptomatic benefit. URL: http://www.clinicaltrials.gov. Unique identifier: NCT02316587. © 2017 American Heart Association, Inc.

  13. Long-term results after proximal thoracic aortic redo surgery.

    Directory of Open Access Journals (Sweden)

    Martin Czerny

    Full Text Available OBJECTIVE: To evaluate early and mid-term results in patients undergoing proximal thoracic aortic redo surgery. METHODS: We analyzed 60 patients (median age 60 years, median logistic EuroSCORE 40 who underwent proximal thoracic aortic redo surgery between January 2005 and April 2012. Outcome and risk factors were analyzed. RESULTS: In hospital mortality was 13%, perioperative neurologic injury was 7%. Fifty percent of patients underwent redo surgery in an urgent or emergency setting. In 65%, partial or total arch replacement with or without conventional or frozen elephant trunk extension was performed. The preoperative logistic EuroSCORE I confirmed to be a reliable predictor of adverse outcome- (ROC 0.786, 95%CI 0.64-0.93 as did the new EuroSCORE II model: ROC 0.882 95%CI 0.78-0.98. Extensive individual logistic EuroSCORE I levels more than 67 showed an OR of 7.01, 95%CI 1.43-34.27. A EuroSCORE II larger than 28 showed an OR of 4.44 (95%CI 1.4-14.06. Multivariate logistic regression analysis identified a critical preoperative state (OR 7.96, 95%CI 1.51-38.79 but not advanced age (OR 2.46, 95%CI 0.48-12.66 as the strongest independent predictor of in-hospital mortality. Median follow-up was 23 months (1-52 months. One year and five year actuarial survival rates were 83% and 69% respectively. Freedom from reoperation during follow-up was 100%. CONCLUSIONS: Despite a substantial early attrition rate in patients presenting with a critical preoperative state, proximal thoracic aortic redo surgery provides excellent early and mid-term results. Higher EuroSCORE I and II levels and a critical preoperative state but not advanced age are independent predictors of in-hospital mortality. As a consequence, age alone should no longer be regarded as a contraindication for surgical treatment in this particular group of patients.

  14. Second-generation endometrial ablation technologies: the hot liquid balloons.

    Science.gov (United States)

    Vilos, George A; Edris, Fawaz

    2007-12-01

    Hysteroscopic endometrial ablation (HEA) was introduced in the 1980s to treat menorrhagia. Its use required additional training, surgical expertise and specialized equipment to minimize emergent complications such as uterine perforations, thermal injuries and excessive fluid absorption. To overcome these difficulties and concerns, thermal balloon endometrial ablation (TBEA) was introduced in the 1990s. Four hot liquid balloons have been introduced into clinical practice. All systems consist of a catheter (4-10mm diameter), a silicone balloon and a control unit. Liquids used to inflate the balloons include internally heated dextrose in water (ThermaChoice, 87 degrees C), and externally heated glycine (Cavaterm, 78 degrees C), saline (Menotreat, 85 degrees ) and glycerine (Thermablate, 173 degrees C). All balloons require pressurization from 160 to 240 mmHg for treatment cycles of 2 to 10 minutes. Prior to TBEA, preoperative endometrial thinning, including suction curettage, is optional. Several RCTs and cohort studies indicate that the advantages of TBEA include portability, ease of use and short learning curve. In addition, small diameter catheters requiring minimal cervical dilatation (5-7 mm) and short duration of treatment cycles (2-8 min) allow treatment under minimal analgesia/anesthesia requirements in a clinic setting. Following TBEA serious adverse events, including thermal injuries to viscera have been experienced. To minimize such injuries some surgeons advocate the use of routine post-dilatation hysteroscopy and/or ultrasonography to confirm correct intrauterine placement of the balloon prior to initiating the treatment cycle. After 10 years of clinical practice, TBEA is thought to be the preferred first-line surgical treatment of menorrhagia in appropriately selected candidates. Economic modeling also suggested that TBEA may be more cost-effective than HEA.

  15. Valve-sparing aortic root replacement†.

    Science.gov (United States)

    Koolbergen, David R; Manshanden, Johan S J; Bouma, Berto J; Blom, Nico A; Mulder, Barbara J M; de Mol, Bas A J M; Hazekamp, Mark G

    2015-02-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed. Median age was 40.3 (range: 13.4-68.6) years and 67 (69.1%) were male. Seven (7.2%) patients were younger than 18 years, the youngest being 13.4 years. Fifty-four (55.7%) had Marfan syndrome, 2 (2.1%) other fibrous tissue diseases, 15 (15.5%) bicuspid aortic valve and 3 (3.1%) had earlier Fallot repair. The reimplantation technique was used in all, with a straight vascular prosthesis in 11 (26-34 mm) and the Valsalva prosthesis in 86 (26-32 mm). Concomitant aortic valve repair was performed in 43 (44.3%), mitral valve repair in 10 (10.3%), tricuspid valve repair in 5 (5.2%) and aortic arch replacement in 3 (3.1%). Mean follow-up was 4.2 ± 2.4 years. Follow-up was complete in all. One 14-year old patient died 1.3 years post-surgery presumably of ventricular arrhythmia. One patient underwent reoperation for aneurysm of the proximal right coronary artery after 4.9 years and 4 patients required aortic valve replacement, 3 of which because of endocarditis after 0.1, 0.8 and 1.3 years and 1 because of cusp prolapse after 3.8 years. No thrombo-embolic complications occurred. Mortality, root reoperation and aortic regurgitation were absent in 88.0 ± 0.5% at 5-year follow-up. Results of valve-sparing root replacement are good, even in association with a high incidence of concomitant valve repair. Valve-sparing aortic root replacement can be performed at a very young age as long as an adult size prosthesis can be implanted. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  16. Endometrial ablation by rollerball electrocoagulation compared to uterine balloon thermal ablation. Technical and safety aspects.

    NARCIS (Netherlands)

    Zon-Rabelink, I.A.A. van; Vleugels, M.P.; Merkus, J.M.W.M.; Graaf, R.M. de

    2003-01-01

    OBJECTIVE: To compare two methods of endometrial ablation, hysteroscopic rollerball electrocoagulation (RBE) and non-hysteroscopic uterine balloon thermal (UBT) ablation (Thermachoice), regarding intra- and post-operative technical complications and safety aspects. STUDY DESIGN: A randomised

  17. Effects of Balloon Pulmonary Valvuloplasty as Preoperative Palliation for Tetralogy of Fallot.

    Science.gov (United States)

    Kim, Geena; Ban, Gil Ho; Lee, Hyoung Doo; Sung, Si Chan; Kim, Hyungtae; Choi, Kwang Ho

    2016-07-01

    We investigated the effect of balloon pulmonary valvuloplasty (BPV) as a palliative procedure for patients with tetralogy of Fallot (TOF). This was a retrospective single-center study conducted between 2008 and 2014. We classified patients into three groups according to palliation: treatment with BPV (group I), with a Blalock-Taussig shunt (group II), and with infundibulectomy (group III). The growth of the pulmonary valve (PV) annulus and need for transannular patching (TAP) during total correction were compared between groups. Forty-eight patients were enrolled: 31, 10, and 7 in groups I, II, and III, respectively. The mean ages at palliation were 26.3 ± 23.6, 21.5 ± 16.4, and 15.2 ± 4.2 days in groups I, II, and III, respectively (P = .867). The success rate of BPV was 90.3%. The initial PV z-score before palliation did not differ between groups I, II, and III (-3.14 ± 1.44, -3.84 ± 1.47, and -3.71 ± 1.68; P = .494); the preoperative PV z-score before total correction was larger in group I than in group II (-1.19 ± 1.14 and -3.05 ± 1.19; P = .001), and also larger in group III than in group II (group III: -1.10 ± 0.90; P = .003). The change in pulse oxygen saturation differed significantly between the three groups (P = .031), particularly between groups I and II (P = .010), and the change in PV z-score was greater in groups I and III than in group II (P < .001). TAP during total correction was performed in 29.0%, 90.0%, and 16.7% of groups I, II, and III, respectively (P = .001; group I vs. II, P = .001; group II vs. III, P = .008). BPV was an effective and safe palliation that increased pulmonary blood flow and promoted growth of the PV annulus in selected symptomatic newborns with TOF. © 2016 Wiley Periodicals, Inc.

  18. Use of real-time three-dimensional transesophageal echocardiography in type A aortic dissections: Advantages of 3D TEE illustrated in three cases

    Directory of Open Access Journals (Sweden)

    Cindy J Wang

    2015-01-01

    Full Text Available Stanford type A aortic dissections often present to the hospital requiring emergent surgical intervention. Initial diagnosis is usually made by computed tomography; however transesophageal echocardiography (TEE can further characterize aortic dissections with specific advantages: It may be performed on an unstable patient, it can be used intra-operatively, and it has the ability to provide continuous real-time information. Three-dimensional (3D TEE has become more accessible over recent years allowing it to serve as an additional tool in the operating room. We present a case series of three patients presenting with type A aortic dissections and the advantages of intra-operative 3D TEE to diagnose the extent of dissection in each case. Prior case reports have demonstrated the use of 3D TEE in type A aortic dissections to characterize the extent of dissection and involvement of neighboring structures. In our three cases described, 3D TEE provided additional understanding of spatial relationships between the dissection flap and neighboring structures such as the aortic valve and coronary orifices that were not fully appreciated with two-dimensional TEE, which affected surgical decisions in the operating room. This case series demonstrates the utility and benefit of real-time 3D TEE during intra-operative management of a type A aortic dissection.

  19. Nursing cooperation in endovascular aneurysm repair treatment for aortic dissection

    International Nuclear Information System (INIS)

    Xing Li; Yuan Chanjuan; Chen Rumei; Xiao Zhanqiang; Qi Youfei

    2014-01-01

    Objective: To summarize the main points of nursing cooperation in endovascular aneurysm repair treatment for aortic dissection. Methods: Preoperative psychological care and the other preparations were carefully conducted. During the operation, the patient's body was correctly placed. Active cooperation with the performance of angiography and close observation during heparinization were carried out. The proper delivery of catheter and stent to the operator was carefully done. Close observation for the patient's vital signs, the renal function and the changes of limb blood supply were made. Results: Under close cooperation of' the operators, nurses, anesthesiologists and technicians, the surgery was successfully accomplished in 35 patients. The monitoring of vital signs during the entire performance of operation was well executed. No surgical instruments delivery error's or surgery failure due to unsuitable cooperation occurred. Conclusion: Perfect preoperative preparation, strict nursing cooperation and team cooperation are the key points to ensure a successful endovascular aneurysm repair for aortic dissection. (authors)

  20. Lower extremity revascularization without preoperative contrast arteriography: experience with duplex ultrasound arterial mapping in 485 cases.

    Science.gov (United States)

    Ascher, Enrico; Hingorani, Anil; Markevich, Natalia; Costa, Tatiana; Kallakuri, Shreedhar; Khanimoy, Yuri

    2002-01-01

    This study reviews our experience with duplex ultrasound arterial mapping (DUAM) for preoperative evaluation in 466 patients (262 men) who underwent 485 lower extremity revascularization procedures from January 1, 1998 to May 30, 2001. Preoperative imaging consisted of DUAM alone in 449 procedures and DUAM and contrast angiography (CA) in 36. An attempt to image from the distal aorta to the pedal arteries was made in all the patients. The selection of optimal inflow and outflow bypasses anastomotic sites was based on a schematic drawing following DUAM examination. Inflow disease was also assessed by intraoperative pressure gradient (IPG) between the distal anastomosis and radial arteries, and completion arteriography of the runoff vessels was obtained, which was correlated with the preoperative findings. Indications for surgery were severe claudication in 91 (19%) limbs, tissue loss in 197 (40%), rest pain in 113 (23%), acute ischemia in 46 (10%), popliteal aneurysm in 18 (4%), superficial femoral artery aneurysm in 1, abdominal aortic aneurysm with claudication in 1, and failing graft in 18 (4%). Age ranged from 30 to 97 years (mean 72 +/- 12 (SD) years) and risk factors such as diabetes, hypertension, use of tobacco, coronary artery disease, and end-stage renal disease were present in 45%, 45%, 44%, 44%, and 13% of the patients, respectively. One hundred twenty-one (25%) limbs had at least 1 previous ipsilateral revascularization. The mean DUAM time was 66 +/- 20 (SD) min (30-150 min). Additional preoperative imaging was deemed necessary in 36 cases due to extensive ulcers, edema, severe arterial wall calcification, and very poor runoff. The distal anastomosis was to the popliteal artery in 173 cases and to the tibial and pedal arteries in 255. Inflow procedures to the femoral arteries, embolectomy, thrombectomy, balloon angioplasty, and patch angioplasty accounted for the remaining 57 cases. Overall, 6-, 12-, and -24- month secondary patency rates were 86%, 80

  1. Understanding Hematopoietic Stem Cell Development through Functional Correlation of Their Proliferative Status with the Intra-aortic Cluster Architecture

    Directory of Open Access Journals (Sweden)

    Antoniana Batsivari

    2017-06-01

    Full Text Available During development, hematopoietic stem cells (HSCs emerge in the aorta-gonad-mesonephros (AGM region through a process of multi-step maturation and expansion. While proliferation of adult HSCs is implicated in the balance between self-renewal and differentiation, very little is known about the proliferation status of nascent HSCs in the AGM region. Using Fucci reporter mice that enable in vivo visualization of cell-cycle status, we detect increased proliferation during pre-HSC expansion followed by a slowing down of cycling once cells start to acquire a definitive HSC state, similar to fetal liver HSCs. We observe time-specific changes in intra-aortic hematopoietic clusters corresponding to HSC maturation stages. The proliferative architecture of the clusters is maintained in an orderly anatomical manner with slowly cycling cells at the base and more actively proliferating cells at the more apical part of the cluster, which correlates with c-KIT expression levels, thus providing an anatomical basis for the role of SCF in HSC maturation.

  2. Preoperative CT evaluation of adenocarcinoma of the gastroesophageal junction

    International Nuclear Information System (INIS)

    Bennett, J.D.; Lefcoe, M.S.; Finley, R.; Yoshi, C.; Inculet, R.

    1988-01-01

    A retrospective review was undertaken of 53 preoperative computed tomographic (CT) scans obtained between March 1983 and April 1988 from patients undergoing surgery for adenocarcinoma of the gastroesophageal junction, and results were correlated with the surgical-pathologic findings. CT was unreliable in predicting aortic, pericardial, or pancreatic invasion (sensitivity, 0/8; specificity, 41/45). Of 45 pathologically positive nodal groups, the largest node measured on CT scans was 10 mm or less in 36 cases. The accuracy of preoperative CT in staging adenocarcinoma of the gastroesophageal junction is limited by its low sensitivity in detecting local invasion. Nodal size as measured with CT is not a reliable indicator of metastatic disease

  3. Application of new balloon catheters in the treatment of congenital heart defects

    Directory of Open Access Journals (Sweden)

    Roland Fiszer

    2016-08-01

    Full Text Available Introduction : Balloon angioplasty (BAP and aortic or pulmonary balloon valvuloplasty (BAV, BPV are well-established treatment options in congenital heart defects. Recently, significant technological progress has been made and new catheters have been implemented in clinical practice. Aim: To analyze the results of BAP, BAV and BPV with the new balloon catheter Valver and its second generation Valver II, which the company Balton (Poland launched and developed. These catheters have not been clinically evaluated yet. Material and methods: We performed 64 interventions with Valver I and Valver II. With Valver I the following procedures were performed: 17 BPV (including 9 in tetralogy of Fallot – TOF, 10 BAV and 27 BAP in coarctations of the aorta (CoA – including 9 native and 18 after surgery. With Valver II ten interventions were done – 3 BPV, 2 pulmonary supravalvular BAP (after switch operations, 2 BAP of recoarctations and 3 other BAP. Age of the patients ranged from a few days to 40 years. Results: All procedures were completed successfully, without rupture of any balloon catheters. The pressure gradient drop was statistically significant in all groups: BPV in isolated pulmonary valvular stenosis 28.1 mm Hg (mean, BPV in TOF 18.7 mm Hg, BAV 32.8 mm Hg, BAP in native CoA 15.4 mm Hg and in recoarctations 18.6 mm Hg. In 3 cases during rapid deflation of Valver I, wrinkles of the balloons made it impossible to insert the whole balloon into the vascular sheath (all were removed surgically from the groin. No such complication occured with Valver II. Conclusions : Valver balloon catheters are an effective treatment modality in different valvular and vascular stenoses.

  4. Aortic root, not valve, calcification correlates with coronary artery calcification in patients with severe aortic stenosis

    DEFF Research Database (Denmark)

    Henein, Michael; Hällgren, Peter; Holmgren, Anders

    2015-01-01

    calcification (AVC), due to tissue similarity between the two types of vessel rather than with the valve leaflet tissue. MATERIAL AND METHODS: We studied 212 consecutive patients (age 72.5 ± 7.9 years, 91 females) with AS requiring aortic valve replacement (AVR) in two Heart Centers, who underwent multidetector...... cardiac CT preoperatively. CAC, AVC and ARC were quantified using Agatston scoring. Correlations were tested by Spearman's test and Mann-Whitney U-test was used for comparing different subgroups; bicuspid (BAV) vs tricuspid (TAV) aortic valve. RESULTS: CAC was present in 92%, AVC in 100% and ARC in 82......% of patients. CAC correlated with ARC (rho = 0.51, p AVC. The number of calcified coronary arteries correlated with ARC (rho = 0.45, p AVC. 29/152 patients had echocardiographic evidence of BAV and 123 TAV, who were older (p

  5. Balloon Cell Urethral Melanoma: Differential Diagnosis and Management

    Directory of Open Access Journals (Sweden)

    M. McComiskey

    2015-01-01

    Full Text Available Introduction. Primary malignant melanoma of the urethra is a rare tumour (0.2% of all melanomas that most commonly affects the meatus and distal urethra and is three times more common in women than men. Case. A 76-year-old lady presented with vaginal pain and discharge. On examination, a 4 cm mass was noted in the vagina and biopsy confirmed melanoma of a balloon type. Preoperative CT showed no distant metastases and an MRI scan of the pelvis demonstrated no associated lymphadenopathy. She underwent anterior exenterative surgery and vaginectomy also. Histology confirmed a urethral nodular malignant melanoma. Discussion. First-line treatment of melanoma is often surgical. Adjuvant treatment including chemotherapy, radiotherapy, or immunotherapy has also been reported. Even with aggressive management, malignant melanoma of the urogenital tract generally has a poor prognosis. Recurrence rates are high and the mean period between diagnosis and recurrence is 12.5 months. A 5-year survival rate of less than 20% has been reported in balloon cell melanomas along with nearly 20% developing local recurrence. Conclusion. To the best of our knowledge, this case is the first report of balloon cell melanoma arising in the urethra. The presentation and surgical management has been described and a literature review provided.

  6. Balloon-Occluded Carbon Dioxide Gas Angiography for Internal Iliac Arteriography and Intervention.

    Science.gov (United States)

    Kishino, Mitsuhiro; Nakaminato, Shuichiro; Kitazume, Yoshio; Miyasaka, Naoyuki; Kudo, Toshifumi; Saida, Yukihisa; Tateishi, Ukihide

    2018-07-01

    The usefulness of carbon dioxide (CO 2 ) gas digital subtraction angiography (DSA) has been reported for patients with renal insufficiency and allergy to iodinated contrast agents. However, CO 2 gas cannot replace the iodinated contrast agent in all cases owing to some disadvantages. We describe balloon-occluded CO 2 DSA (B-CO 2 DSA) as an improved CO 2 DSA procedure for interventions in the internal iliac artery (IIA) region and compare the quality of images obtained using conventional CO 2 DSA and B-CO 2 DSA. B-CO 2 DSA-guided embolization was performed for one case of genital bleeding with an acute anaphylactic reaction to the iodinated contrast agent and for three cases of type II endoleaks after endovascular abdominal aortic aneurysm repair with renal dysfunction. A 9-mm occlusion balloon catheter was placed just after the orifice of the IIA. Then, 10-15 ml of CO 2 gas was injected manually via the catheter with and without balloon occlusion. The quality of sequential digital subtraction angiograms was analyzed based on a scoring criterion. In all four cases, image quality was improved with B-CO 2 DSA; the poor quality of images without balloon occlusion was because of reflux of the CO 2 gas. B-CO 2 DSA improves the image quality of CO 2 DSA in the IIA region and is useful for vascular intervention. Level IV.

  7. Use of an Automated Suture Fastening Device in Minimally Invasive Aortic Valve Replacement.

    Science.gov (United States)

    Beute, Tyler J; Orem, Matthew D; Schiller, Timothy M; Goehler, Matthew; Parker, Jessica; Willekes, Charles L; Timek, Tomasz

    2018-03-01

    Minimally invasive aortic valve replacement (mAVR) is gaining clinical acceptance, however, it is associated with increased operative times due to limited surgical field and access. The Cor-Knot is an automated fastening device designed to facilitate suture fastening, but clinical data in mAVR are lacking. From May 2014 to February 2017, 92 patients underwent mAVR at our center with 39 valves secured with manually-tied (MT) sutures and 53 valves entirely secured with the Cor-Knot (CK). Pre-operative characteristics and 30-day outcomes data were extracted from our local Society of Thoracic Surgeons database and the electronic medical record. Survival data were obtained from the Michigan State Social Security Death Index. No significant difference in pre-operative characteristics were noted between the two groups. Aortic cross-clamp time (72±12 min vs 82±15 min, p=0.001) was significantly shorter with CK. There was no difference in post-operative mortality (0% vs 0%), stroke (0% vs 1.9%), atrial fibrillation (28% vs 33%), renal failure (0% vs 3.8%), or pacemaker implantation (5.1% vs 5.7%) between MT and CK. Valve function on post-operative echocardiography and 1-year patient survival were similar. In minimally invasive aortic valve replacement, the Cor-Knot device was associated with reduced aortic cross-clamp time while providing equivalent clinical outcomes. Larger studies are needed to confirm efficacy, safety, and cost-effectiveness of the Cor-Knot device in minimally invasive aortic valve surgery. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Updated clinical indications for transcatheter aortic valve implantation in patients with severe aortic stenosis: expert opinion of the Italian Society of Cardiology and GISE.

    Science.gov (United States)

    Indolfi, Ciro; Bartorelli, Antonio L; Berti, Sergio; Golino, Paolo; Esposito, Giovanni; Musumeci, Giuseppe; Petronio, Sonia; Tamburino, Corrado; Tarantini, Giuseppe; Ussia, Gianpaolo; Vassanelli, Corrado; Spaccarotella, Carmen; Violini, Roberto; Mercuro, Giuseppe; Romeo, Francesco

    2018-05-01

    : The introduction of percutaneous treatment of severe aortic stenosis with transcatheter aortic valve implantation (TAVI) remains one of the greatest achievements of interventional cardiology. In fact, TAVI emerged as a better option than either medical therapy or balloon aortic valvuloplasty for patients who cannot undergo surgical aortic valve replacement (SAVR) or are at high surgical risk. Recently, increased operator experience and improved device systems have led to a worldwide trend toward the extension of TAVI to low-risk or intermediate-risk patients. In this expert opinion paper, we first discuss the basic pathophysiology of aortic stenosis in different settings then the key results of recent clinical investigations on TAVI in intermediate-risk aortic stenosis patients are summarized. Particular emphasis is placed on the results of the nordic aortic valve intervention, placement of aortic transcatheter valves (PARTNER) 2 and Surgical Replacement and Transcatheter Aortic Valve Implantation Randomized trials. The PARTNER 2 was the first large randomized trial that evaluated the outcome of TAVI in patients at intermediate risk. The PARTNER 2 data demonstrated that TAVI is a feasible and reasonable alternative to surgery in intermediate-risk patients (Society of Thoracic Surgeons 4-8%), especially if they are elderly or frail. There was a significant interaction between TAVI approach and mortality, with transfemoral TAVI showing superiority over SAVR. Moreover, we examine the complementary results of the recently concluded Surgical Replacement and Transcatheter Aortic Valve Implantation trial. This prospective randomized trial demonstrated that TAVI is comparable with surgery (primary end point 12.6% in the TAVI group vs. 14.0% in the SAVR group) in severe aortic stenosis patients deemed to be at intermediate risk. We review the most relevant clinical evidence deriving from nonrandomized studies and meta-analyses. Altogether, clinical outcome available data

  9. Navigation for fluoroscopy-guided cryo-balloon ablation procedures of atrial fibrillation

    Science.gov (United States)

    Bourier, Felix; Brost, Alexander; Kleinoeder, Andreas; Kurzendorfer, Tanja; Koch, Martin; Kiraly, Attila; Schneider, Hans-Juergen; Hornegger, Joachim; Strobel, Norbert; Kurzidim, Klaus

    2012-02-01

    Atrial fibrillation (AFib), the most common arrhythmia, has been identified as a major cause of stroke. The current standard in interventional treatment of AFib is the pulmonary vein isolation (PVI). PVI is guided by fluoroscopy or non-fluoroscopic electro-anatomic mapping systems (EAMS). Either classic point-to-point radio-frequency (RF)- catheter ablation or so-called single-shot-devices like cryo-balloons are used to achieve electrically isolation of the pulmonary veins and the left atrium (LA). Fluoroscopy-based systems render overlay images from pre-operative 3-D data sets which are then merged with fluoroscopic imaging, thereby adding detailed 3-D information to conventional fluoroscopy. EAMS provide tracking and visualization of RF catheters by means of electro-magnetic tracking. Unfortunately, current navigation systems, fluoroscopy-based or EAMS, do not provide tools to localize and visualize single shot devices like cryo-balloon catheters in 3-D. We present a prototype software for fluoroscopy-guided ablation procedures that is capable of superimposing 3-D datasets as well as reconstructing cyro-balloon catheters in 3-D. The 3-D cyro-balloon reconstruction was evaluated on 9 clinical data sets, yielded a reprojected 2-D error of 1.72 mm +/- 1.02 mm.

  10. The preliminary study on a single balloon cross-medline expansion using unipedicular approach in kyphoplasty

    International Nuclear Information System (INIS)

    Sun Gang; Jin Peng; Liu Xunwei; Hao Runsong; Xie Zhiyong; Li Fandong; Yi Yuhai; Zhang Xuping

    2008-01-01

    Objective: To evaluate the clinical efficacy and safety of kyphoplasty with single balloon cross-midline expansion using unipedicular approach for osteoporotic vertebral body compressive fracture (OVCF). Methods: Thirty six cases of painful OVCF were included in the study, with 61 vertebrae involved. Under X-ray fluoroscopy monitoring, kyphoplasty was performed using a unilateral, single, balloon via a unilateral transpedicular approach. A final balloon position was in the midline of the vertebral body with the balloon cross-midline expansions and bone cement filled. Clinical outcomes were determined by comparison of preoperative and postoperative VAS and ODI scores. Radiographic assessment included vertebral height restoration and correction of kyphosis. Follow-up was conducted for 6.0-12.0 months (mean 9.2 months). Results: Thirty-six consecutive patients with 61 vertebrae were successfully operated with an operative time of (37.4 ± 9.6) min per vertebra. All patients had significant pain relief and functional recovery within 96 h after the procedure with no surgery- and device-related complications. VAS score improved from (7.3 ± 1.0) preoperatively to (2.7 ± 0.8) postoperatively (t=19.53, P<0.01). ODI score was decreased from(71.1±10.9)% preoperatively to(26.6±6.4)% postoperatively(t=18.54, P<0.01). The average anterior body height loss was (14.3±2.8) mm before procedure and (10.0 ± 1.8) mm after procedure (t=14.68, P<0.01). The average middle body height loss was (10.2 ± 2.7) mm before procedure and (5.9±1.8) mm after procedure (t=16.44,P<0.01). The Cobb's angle was corrected from 23.4 degree ± 5.0 degree to 16.2 degree ± 2.8 degree (t=15.60,P<0.01). Some leakages of cement around the anterior margin of vertebra and inter-vertebral space were found in 2 patients, but there were no clinical symptoms. X-ray examination indicated there were no cement leakages in other vertebra. The pain relief and functional recovery were substantial and maintained to

  11. Impact of secondary hyperparathyroidism on ventricular mass regression after aortic valve replacement for aortic stenosis in hemodialysis-dependent patients.

    Science.gov (United States)

    Takami, Yoshiyuki; Tajima, Kazuyoshi

    2015-07-01

    In hemodialysis (HD)-dependent patients, secondary hyperparathyroidism induces cardiac hypertrophy. This study investigated whether parathyroid hormone (PTH) levels affect the degree of left ventricular (LV) mass regression in HD patients after aortic valve replacement (AVR) for aortic stenosis (AS). We retrospectively obtained preoperative and 2-year postoperative echocardiography and intact PTH measurements in 88 HD patients who underwent AVR, with bioprostheses (n = 35, 40%) and mechanical valves (n = 53, 60%) of effective orifice area >0.80 cm2/m2, between January 1997 and December 2010. The LV mass decreased significantly from 308 ± 88 to 217 ± 68 g at follow-up of 28 ± 4 months after AVR (p regression at follow-up was inversely related to preoperative PTH values (R = 0.44, p = 0.001). The LV mass regression at follow-up was significantly smaller in the patients (n = 47) with PTH ≥100 pg/mL than in those (n = 41) with PTH regression at 2-year follow-up (β = 0.23, r2 = 0.24, p = 0.02). In conclusion, the HD patients with high levels of PTH presented with less LV mass regression after AVR for AS without patient-prosthesis mismatch. Secondary hyperparathyroidism may impair regression of cardiac hypertrophy after AVR in HD patients with AS.

  12. [Pre-operation evaluation and intra-operation management of cochlear implantation].

    Science.gov (United States)

    Zhang, Dao-xing; Hu, Bao-hua; Xiao, Yu-li; Shi, Bo-ning

    2004-10-01

    To summarize pre-operation evaluation experiences in cochlear implantation. Performing auditory evaluation and image analysis seriously in 158 severe hearing loss or total deaf cases before cochlear implantation, comparing their performance with the findings during and post operation. Among the total 158 cases, 116 cases with normal structure, 42 cases with the abnormal findings of the inner or middle ear. Stapedial gusher happened in 6 cases, 1 case was not predicted before operation. Except 1 case with serious malformation, the findings of other 157 cases in operation were consistent with the pre-operation evaluation. We helped all patients reconstruct auditory conduction with cochlear implantation, and the average hearing level up to 37.6 dB SPL. Performing image analysis seriously before operation and planning for operation according to HRCT can do great help to cochlear implantation. The operation under the HRCT instruction has less complications.

  13. Suprarenal fixation resulting in intestinal malperfusion after endovascular aortic aneurysm repair.

    Science.gov (United States)

    Siani, Andrea; Accrocca, Federico; De Vivo, Gennaro; Marcucci, Giustino

    2016-05-01

    Superior mesenteric artery (SMA) and coeliac axis (CA) occlusion after endovascular abdominal aneurysm aortic repair (EVAR-AAA), using endograft with suprarenal fixation, are uncommon. However, we are reporting a case of visceral malperfusion, which occurred 7 days after successful EVAR with suprarenal fixation for symptomatic AAA. Endograft metal stent barbs caused severe stenosis of SMA and CA. A successful recovery of SMA was carried out by means of a balloon-expandable stent released through bare metal stent barbs. We believe that an unfavourable anatomy of a proximal aortic neck and visceral aorta may have caused a wrong stent strut deployment with the coverage of CA and SMA. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  14. Understanding Hematopoietic Stem Cell Development through Functional Correlation of Their Proliferative Status with the Intra-aortic Cluster Architecture.

    Science.gov (United States)

    Batsivari, Antoniana; Rybtsov, Stanislav; Souilhol, Celine; Binagui-Casas, Anahi; Hills, David; Zhao, Suling; Travers, Paul; Medvinsky, Alexander

    2017-06-06

    During development, hematopoietic stem cells (HSCs) emerge in the aorta-gonad-mesonephros (AGM) region through a process of multi-step maturation and expansion. While proliferation of adult HSCs is implicated in the balance between self-renewal and differentiation, very little is known about the proliferation status of nascent HSCs in the AGM region. Using Fucci reporter mice that enable in vivo visualization of cell-cycle status, we detect increased proliferation during pre-HSC expansion followed by a slowing down of cycling once cells start to acquire a definitive HSC state, similar to fetal liver HSCs. We observe time-specific changes in intra-aortic hematopoietic clusters corresponding to HSC maturation stages. The proliferative architecture of the clusters is maintained in an orderly anatomical manner with slowly cycling cells at the base and more actively proliferating cells at the more apical part of the cluster, which correlates with c-KIT expression levels, thus providing an anatomical basis for the role of SCF in HSC maturation. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  15. Intensive Care Management of Thoracic Aortic Surgical Patients, Including Thoracic and Infradiaphragmatic Endovascular Repair (EVAR/TEVAR).

    Science.gov (United States)

    Cole, Sheela Pai

    2015-12-01

    The patient with thoracic aortic disease can present for open or endovascular repair. Thoracic endovascular aortic repair (TEVAR) has emerged as a minimally invasive option for a multitude of aortic pathology, including dissections, aneurysms, traumatic injuries, and ulcers. Postoperative management of these patients depends on the extent of procedure, whether it was open or endovascular, and, finally, on the preoperative comorbidities present. While procedural success has catapulted TEVAR to popularity, midterm results have been mixed. Additionally, periprocedural complications such as paraplegia and renal failure remain a significant morbidity in these patients. © The Author(s) 2015.

  16. CT-angiography-based evaluation of the aortic annulus for prosthesis sizing in transcatheter aortic valve implantation (TAVI)-predictive value and optimal thresholds for major anatomic parameters.

    Science.gov (United States)

    Schwarz, Florian; Lange, Philipp; Zinsser, Dominik; Greif, Martin; Boekstegers, Peter; Schmitz, Christoph; Reiser, Maximilian F; Kupatt, Christian; Becker, Hans C

    2014-01-01

    To evaluate the predictive value of CT-derived measurements of the aortic annulus for prosthesis sizing in transcatheter aortic valve implantation (TAVI) and to calculate optimal cutoff values for the selection of various prosthesis sizes. The local IRB waived approval for this single-center retrospective analysis. Of 441 consecutive TAVI-patients, 90 were excluded (death within 30 days: 13; more than mild aortic regurgitation: 10; other reasons: 67). In the remaining 351 patients, the CoreValve (Medtronic) and the Edwards Sapien XT valve (Edwards Lifesciences) were implanted in 235 and 116 patients. Optimal prosthesis size was determined during TAVI by inflation of a balloon catheter at the aortic annulus. All patients had undergone CT-angiography of the heart or body trunk prior to TAVI. Using these datasets, the diameter of the long and short axis as well as the circumference and the area of the aortic annulus were measured. Multi-Class Receiver-Operator-Curve analyses were used to determine the predictive value of all variables and to define optimal cutoff-values. Differences between patients who underwent implantation of the small, medium or large prosthesis were significant for all except the large vs. medium CoreValve (all p'sprosthesis size for both manufacturers (multi-class AUC's: 0.80, 0.88, 0.91, 0.88, 0.88, 0.89). Using the calculated optimal cutoff-values, prosthesis size is predicted correctly in 85% of cases. CT-based aortic root measurements permit excellent prediction of the prosthesis size considered optimal during TAVI.

  17. The German Aortic Valve Registry (GARY): a nationwide registry for patients undergoing invasive therapy for severe aortic valve stenosis.

    Science.gov (United States)

    Beckmann, A; Hamm, C; Figulla, H R; Cremer, J; Kuck, K H; Lange, R; Zahn, R; Sack, S; Schuler, G C; Walther, T; Beyersdorf, F; Böhm, M; Heusch, G; Funkat, A K; Meinertz, T; Neumann, T; Papoutsis, K; Schneider, S; Welz, A; Mohr, F W

    2012-07-01

    Background The increasing prevalence of severe aortic valve defects correlates with the increase of life expectancy. For decades, surgical aortic valve replacement (AVR), under the use of extracorporeal circulation, has been the gold standard for treatment of severe aortic valve diseases. In Germany ~12,000 patients receive isolated aortic valve surgery per year. For some time, percutaneous balloon valvuloplasty has been used as a palliative therapeutic option for very few patients. Currently, alternatives for the established surgical procedures such as transcatheter aortic valve implantation (TAVI) have become available, but there are only limited data from randomized studies or low-volume registries concerning long-time outcome. In Germany, the implementation of this new technology into hospital care increased rapidly in the past few years. Therefore, the German Aortic Valve Registry (GARY) was founded in July 2010 including all available therapeutic options and providing data from a large quantity of patients.Methods The GARY is assembled as a complete survey for all invasive therapies in patients with relevant aortic valve diseases. It evaluates the new therapeutic options and compares them to surgical AVR. The model for data acquisition is based on three data sources: source I, the mandatory German database for external performance measurement; source II, a specific registry dataset; and source III, a follow-up data sheet (generated by phone interview). Various procedures will be compared concerning observed complications, mortality, and quality of life up to 5 years after the initial procedure. Furthermore, the registry will enable a compilation of evidence-based indication criteria and, in addition, also a comparison of all approved operative procedures, such as Ross or David procedures, and the use of different mechanical or biological aortic valve prostheses.Results Since the launch of data acquisition in July 2010, almost all institutions performing

  18. Type A Aortic Dissection Presenting with Inferior ST-Elevation Myocardial Infarction.

    Science.gov (United States)

    Wu, Bao-Tzung; Li, Chun-Yi; Chen, Ying-Tsung

    2014-05-01

    Type A aortic dissection with concurrent ST-elevation myocardial infarction (STEMI) is relatively rare. However, it can be potentially fatal and easily misdiagnosed as STEMI alone. Misdiagnosis will lead to inappropriate administration of anticoagulant and thrombolytic therapy and delayed surgical repair of the aorta. In patients with STEMI, short reperfusion time is associated with improved survival, and minimizing the door-to-balloon time is the goal of therapy worldwide. However, signs critical for differential diagnosis may be overlooked in the rush to primary percutaneous coronary intervention. When a patient is encountered who presents with chest pain and ST elevation on electrocardiogram, STEMI should not be the only diagnosis considered. By using bedside available information, detailed history taking and focused physical examination, it is possible to avoid a mistaken diagnosis. Here we report a case of Stanford type A aortic dissection with STEMI that was initially misdiagnosed as sole acute inferior wall myocardial infarction. Patient mortality may have resulted from delayed diagnosis and surgical treatment. Acute myocardial infarction; Aortic dissection.

  19. Percutaneous treatment of adult isthmic aortic coarctation: acute and long-term clinical and imaging outcome with a self-expandable uncovered nitinol stent.

    Science.gov (United States)

    Kische, Stephan; D'Ancona, Giuseppe; Stoeckicht, Yannik; Ortak, Jasmin; Elsässer, Albrecht; Ince, Hüseyin

    2015-01-01

    To present perioperative and long-term results of percutaneous treatment of adult isthmic coarctation of the aorta by means of a self-expandable closed-web uncovered nitinol stent (Sinus-XL, Optimed, Esslingen, Germany). Preoperative, perioperative, and long-term clinical and computed tomographic angiography data were collected and analyzed prospectively. A total of 52 consecutive patients were treated with the Sinus-XL stent. Mean age was 36.6 (21-67) years, peak invasive trans-coarctation of the aorta gradient was 54.7 ± 9.9 mm Hg, and upper body hypertension unresponsive to medical treatment was present in all patients. Mean stent diameter and length were 24.2 mm (22-28 mm) and 70.4 mm (40-80 mm), respectively. Eight patients (15.4%) required coarctation of the aorta predilatation. All patients underwent poststent dilatation with a noncompliant balloon. Postoperative peak gradient (3.3 ± 2.5 mm Hg) was reduced significantly (P stent collapse and secondary migration and documented stability in aortic diameter (18.3 ± 2.7 mm). Thirty patients (57.7%) were completely weaned-off antihypertensive medications and their use dropped from 2.6 to 0.9 drugs/patient (P self-expandable uncovered stent is safe and durable. The peculiar stent design maintains adequate localized radial strength over time with minimal trauma on the adjacent aortic wall and negligible device-related complications. Blood pressure control optimization is immediate and persistent even at long-term follow-up. © 2015 American Heart Association, Inc.

  20. Valve-sparing aortic root replacement in Loeys-Dietz syndrome.

    Science.gov (United States)

    Patel, Nishant D; Arnaoutakis, George J; George, Timothy J; Allen, Jeremiah G; Alejo, Diane E; Dietz, Harry C; Cameron, Duke E; Vricella, Luca A

    2011-08-01

    Loeys-Dietz syndrome (LDS) is a recently recognized aggressive aortic disorder characterized by root aneurysm, arterial tortuosity, hypertelorism, and bifid uvula or cleft palate. The results of prophylactic root replacement using valve-sparing procedures (valve-sparing root replacement [VSRR]) in patients with LDS is not known. We reviewed all patients with clinical and genetic (transforming growth factor-β receptor mutations) evidence of LDS who underwent VSRR at our institution. Echocardiographic and clinical data were obtained from hospital and follow-up clinic records. From 2002 to 2009, 31 patients with a firm diagnosis of LDS underwent VSRR for aortic root aneurysm. Mean age was 15 years, and 24 (77%) were children. One (3%) patient had a bicuspid aortic valve. Preoperative sinus diameter was 3.9±0.8 cm (z score 7.0±2.9) and 2 (6%) had greater than 2+ aortic insufficiency. Thirty patients (97%) underwent reimplantation procedures using a Valsalva graft. There were no operative deaths. Mean follow-up was 3.6 years (range, 0 to 7 years). One patient required late repair of a pseudoaneurysm at the distal aortic anastomosis, and 1 had a conversion to a David reimplantation procedure after a Florida sleeve operation. No patient suffered thromboembolism or endocarditis, and 1 (3%) patient experienced greater than 2+ late aortic insufficiency. No patient required late aortic valve repair or replacement. Loeys-Dietz syndrome is an aggressive aortic aneurysm syndrome that can be addressed by prophylactic aortic root replacement with low operative risk. Valve-sparing procedures have encouraging early and midterm results, similar to those in Marfan syndrome, and are an attractive option for young patients. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Intra-arterial digital subtraction angiography of the pulmonary arteries using a flow-directed balloon catheter in the diagnosis of pulmonary embolism

    International Nuclear Information System (INIS)

    Rooij, W.J.J. van; Heeten, G.J. den

    1992-01-01

    Selective intra-arterial digital subtraction angiography (IA-DSA) of the pulmonary vessels was performed in 70 patients suspected of acute pulmonary embolism. A flow-directed Swan-Ganz pulmonary angiography catheter was used. The spatial resolution of the equipment used was 3.3 lp/mm for DSA and 6.0 lp/mm for conventional pulmonary angiography (CPA). Image quality of the angiograms was assessed by determining the highest visible branching division of the main pulmonary artery. The mean visible branching division for IA-DSA was 4.71 (range 3-7). In 10 patients where IA-DSA and CPA were performed during the same procedure there was no difference in visualization of peripheral arteries (mean 4.70 visible or for both modalities). IA-DSA makes the procedure rapid, saves on films and contrast material and allows good visualization of areas where exposure is difficult. The spatial resolution of state-of-the-art equipment permits sufficient definition of subsegmental vessels. The use of the flow-directed balloon catheter makes the examination easy to perform and minimizes the risk of catheter induced cardiac arrhythmias. (orig.) [de

  2. Supra-annular structure assessment for self-expanding transcatheter heart valve size selection in patients with bicuspid aortic valve.

    Science.gov (United States)

    Liu, Xianbao; He, Yuxin; Zhu, Qifeng; Gao, Feng; He, Wei; Yu, Lei; Zhou, Qijing; Kong, Minjian; Wang, Jian'an

    2018-04-01

    To explore assessment of supra-annular structure for self-expanding transcatheter heart valve (THV) size selection in patients with bicuspid aortic stenosis (AS). Annulus-based device selection from CT measurement is the standard sizing strategy for tricuspid aortic valve before transcatheter aortic valve replacement (TAVR). Because of supra-annular deformity, device selection for bicuspid AS has not been systemically studied. Twelve patients with bicuspid AS who underwent TAVR with self-expanding THVs were included in this study. To assess supra-annular structure, sequential balloon aortic valvuloplasty was performed in every 2 mm increments until waist sign occurred with less than mild regurgitation. Procedural results and 30 day follow-up outcomes were analyzed. Seven patients (58.3%) with 18 mm; three patients (25%) with sequential 18 mm, 20 mm; and only two patients (16.7%) with sequential 18 mm, 20 mm, and 22 mm balloon sizing were performed, respectively. According to the results of supra-annular assessment, a smaller device size (91.7%) was selected in all but one patient compared with annulus based sizing strategy, and the outcomes were satisfactory with 100% procedural success. No mortality and 1 minor stroke were observed at 30 d follow-up. The percentage of NYHA III/IV decreased from 83.3% (9/12) to 16.7% (2/12). No new permanent pacemaker implantation and no moderate or severe paravalvular leakage were found. A supra-annular structure based sizing strategy is feasible for TAVR in patients with bicuspid AS. © 2018 The Authors Catheterization and Cardiovascular Interventions Published by Wiley Periodicals, Inc.

  3. Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve

    DEFF Research Database (Denmark)

    Aagaard, Jan; Geha, Alexander S.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The CarboMedics Top Hat supra-annular aortic valve allows a one-size (and often two-size) increase over the standard intra-annular valve. This advantage should minimize the risk of patient-prosthesis mismatch, where the effective prosthetic valve orifice area....... This study evaluates the authors' clinical experience with Top Hat supra-annular aortic valve size selection, and the technical aspects of implantation. METHODS: Between January 1999 and October 2005, a total of 251 consecutive patients underwent 252 aortic valve replacements with Top Hat supra...... required unplanned coronary bypass, and 30-day mortality was 2.0% (5/251), indicating a good safety profile for the valves implanted in this series. CONCLUSION: The general distribution of implant sizes in the US indicates that cardiac surgeons may be under-sizing the Top Hat supra-annular aortic valve...

  4. Innovative chimney-graft technique for endovascular repair of a pararenal abdominal aortic aneurysm.

    Science.gov (United States)

    Galiñanes, Edgar Luis; Hernandez-Vila, Eduardo A; Krajcer, Zvonimir

    2015-02-01

    After abdominal aortic aneurysm repair, progressive degeneration of the aneurysm can be challenging to treat. Multiple comorbidities and previous operations place such patients at high risk for repeat surgery. Endovascular repair is a possible alternative; however, challenging anatomy can push the limits of available technology. We describe the case of a 71-year-old man who presented with a 5.3-cm pararenal aneurysm 4 years after undergoing open abdominal aortic aneurysm repair. To avoid reoperation, we excluded the aneurysm by endovascular means, using visceral-artery stenting, a chimney-graft technique. Low-profile balloons on a monorail system enabled the rapid exchange of coronary wires via a buddy-wire technique. This novel approach facilitated stenting and simultaneous angioplasty of multiple visceral vessels and the abdominal aorta.

  5. Computed Tomography Helps to Plan Minimally Invasive Aortic Valve Replacement Operations.

    Science.gov (United States)

    Stoliński, Jarosław; Plicner, Dariusz; Grudzień, Grzegorz; Kruszec, Paweł; Fijorek, Kamil; Musiał, Robert; Andres, Janusz

    2016-05-01

    This study evaluated the role of multidetector computed tomography (MDCT) in preparation for minimally invasive aortic valve replacement (MIAVR). An analysis of 187 patients scheduled for MIAVR between June 2009 and December 2014 was conducted. In the study group (n = 86), MDCT of the thorax, aorta, and femoral arteries was performed before the operation. In the control group (n = 101), patients qualified for MIAVR without receiving preoperative MDCT. The surgical strategy was changed preoperatively in 12.8% of patients from the study group and in 2.0% of patients from the control group (p = 0.010) and intraoperatively in 9.9% of patients from the control group and in none from the study group (p = 0.002). No conversion to median sternotomy was necessary in the study group; among the controls, there were 4.0% conversions. On the basis of the MDCT measurements, optimal access to the aortic valve was achieved when the angle between the aortic valve plane and the line to the second intercostal space was 91.9 ± 10.0 degrees and to the third intercostal space was 94.0 ± 1.4 degrees, with the distance to the valve being 94.8 ± 13.8 mm and 84.5 ± 9.9 mm for the second and third intercostal spaces, respectively. The right atrium covering the site of the aortotomy was present in 42.9% of cases when MIAVR had been performed through the third intercostal space and in 1.3% when through the second intercostal space (p = 0.001). Preoperative MDCT of the thorax, aorta, and femoral arteries makes it possible to plan MIAVR operations. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Risk factors and early outcomes of acute renal injury after thoracic aortic endograft repair for type B aortic dissection

    Directory of Open Access Journals (Sweden)

    Luo S

    2017-08-01

    Full Text Available Songyuan Luo,* Huanyu Ding,* Jianfang Luo, Wei Li, Bing Ning, Yuan Liu, Wenhui Huang, Ling Xue, Ruixin Fan, Jiyan Chen Cardiology Department, Guangdong Cardiovascular Institute, Guangdong Provincial Key Laboratory of Coronary Heart Disease Prevention, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong, China *These authors contributed equally to this work Background: Thoracic endovascular aortic repair (TEVAR has become an emerging treatment modality for acute type B aortic dissection (TBAD patients in recent years. The risk factors and impacts of acute kidney injury (AKI after percutaneous TEVAR, however, have not been widely established.Methods: We retrospectively studied the clinical records of 305 consecutive patients who admitted to our institution and had TEVAR for TBAD between December 2009 and June 2013. The patients were routinely monitored for their renal functions preoperatively until 7 days after TEVAR. The Kidney Disease Improving Global Guidelines (KDIGO criteria were used for AKI.Results: Of the total 305 consecutive patients, 84 (27.5% developed AKI after TEVAR, comprising 66 (21.6% patients in KDIGO stage 1, 6 (2.0% patients in stage 2 and 12 (3.9% patients in stage 3. From the logistic regression analysis, systolic blood pressure (SBP on admission >140 mmHg (odds ratio [OR], 2.288; 95% CI, 1.319–3.969 and supra-aortic branches graft bypass hybrid surgery (OR, 3.228; 95% CI, 1.526–6.831 were independent risk factors for AKI after TEVAR. Local anesthesia tended to be a protective factor (OR, 0.563; 95% CI, 0.316–1.001. The preoperative renal function, angiotensin-converting enzyme inhibitor/angiotensin receptor blocker or statin administration, volume of contrast agent, range of TBAD and false lumen involving renal artery were not associated with post-operation AKI. The in-hospital mortality and major adverse events were markedly increased with the occurrence of AKI (7.1% vs 0.9%, P=0

  7. The Timing of Hip Arthroscopy After Intra-articular Hip Injection Affects Postoperative Infection Risk.

    Science.gov (United States)

    Wang, Dean; Camp, Christopher L; Ranawat, Anil S; Coleman, Struan H; Kelly, Bryan T; Werner, Brian C

    2017-11-01

    To evaluate the association of preoperative intra-articular hip injection with surgical site infection after hip arthroscopy. A large administrative database was used to identify all patients undergoing hip arthroscopy from 2007 to 2015 within a single private insurer and from 2005 to 2012 within Medicare in the United States. Those that received an ipsilateral preoperative intra-articular hip injection were identified. The patients were then divided into the following groups based on the interval between preoperative injection and ipsilateral hip arthroscopy: (1) 12 months) of preoperative hip injection. Patients developing a surgical site infection within 6 months following hip arthroscopy were identified using International Classification of Diseases, Ninth Revision, and Current Procedural Terminology codes associated with infection. Groups were compared using a multivariate logistic regression analysis to control for age, gender, body mass index, smoking status, alcohol usage, and multiple medical comorbidities including diabetes mellitus, hemodialysis use, inflammatory arthritis, and peripheral vascular disease. In total, 19% of privately insured and 6% of Medicare patients received a hip injection within 12 months of hip arthroscopy. The overall infection rate in privately insured and Medicare patients was 1.19% and 1.10%, respectively. Preoperative hip injection within 3 months of surgery was associated with a significantly higher risk of postoperative infection versus controls (2.16%, odds ratio [OR] 6.1, P arthroscopy increased when preoperative intra-articular hip injections were given within 3 months of surgery. Level III, retrospective comparative study. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  8. Evidence, lack of evidence, controversy, and debate in the provision and performance of the surgery of acute type A aortic dissection

    DEFF Research Database (Denmark)

    Bonser, Robert S; Ranasinghe, Aaron M; Loubani, Mahmoud

    2011-01-01

    for malperfusion complications are necessary. The goals of surgery are to save life by prevention of pericardial tamponade or intra-pericardial aortic rupture, to resect the primary entry tear, to correct or prevent any malperfusion and aortic valve regurgitation, and if possible to prevent late dissection...

  9. Impact of around-the-clock in-house cardiology fellow coverage on door-to-balloon time in an academic medical center

    Directory of Open Access Journals (Sweden)

    Kohan LC

    2017-04-01

    Full Text Available Luke C Kohan,1,* Vijaiganesh Nagarajan,1,* Michael A Millard,2 Michael J Loguidice,2 Nancy M Fauber,1 Ellen C Keeley1 1Division of Cardiology, 2Department of Medicine, University of Virginia, Charlottesville, VA, USA * These authors contributed equally to this work Objectives: To assess if a change in our cardiology fellowship program impacted our ST elevation myocardial infarction (STEMI program. Background: Fellows covering the cardiac care unit were spending excessive hours in the hospital while on call, resulting in increased duty hours violations. A night float fellow system was started on July 1, 2012, allowing the cardiac care unit fellow to sign out to a night float fellow at 5:30 pm. The night float fellow remained in-house until the morning. Methods: We performed a retrospective study assessing symptom onset to arrival, arterial access to first device, and door-to-balloon (D2B times, in consecutive STEMI patients presenting to our emergency department before and after initiation of the night float fellow system. Results: From 2009 to 2013, 208 STEMI patients presented to our emergency department and underwent primary percutaneous coronary intervention. There was no difference in symptom onset to arrival (150±102 minutes vs 154±122 minutes, p=0.758, arterial access to first device (12±8 minutes vs 11±7 minutes, p=0.230, or D2B times (50±32 minutes vs 52±34 minutes, p=0.681 during regular working hours. However, there was a significant decrease in D2B times seen during off-hours (72±33 minutes vs 49±15 minutes, p=0.007. There was no difference in in-hospital mortality (11% vs 8%, p=0.484 or need for intra-aortic balloon pump placement (7% vs 8%, p=0.793. Conclusion: In academic medical centers, in-house cardiology fellow coverage during off-hours may expedite care of STEMI patients. Keywords: door-to-balloon time, 24/7 in-house call, cardiology fellow

  10. CT-angiography-based evaluation of the aortic annulus for prosthesis sizing in transcatheter aortic valve implantation (TAVI-predictive value and optimal thresholds for major anatomic parameters.

    Directory of Open Access Journals (Sweden)

    Florian Schwarz

    Full Text Available BACKGROUND/OBJECTIVES: To evaluate the predictive value of CT-derived measurements of the aortic annulus for prosthesis sizing in transcatheter aortic valve implantation (TAVI and to calculate optimal cutoff values for the selection of various prosthesis sizes. METHODS: The local IRB waived approval for this single-center retrospective analysis. Of 441 consecutive TAVI-patients, 90 were excluded (death within 30 days: 13; more than mild aortic regurgitation: 10; other reasons: 67. In the remaining 351 patients, the CoreValve (Medtronic and the Edwards Sapien XT valve (Edwards Lifesciences were implanted in 235 and 116 patients. Optimal prosthesis size was determined during TAVI by inflation of a balloon catheter at the aortic annulus. All patients had undergone CT-angiography of the heart or body trunk prior to TAVI. Using these datasets, the diameter of the long and short axis as well as the circumference and the area of the aortic annulus were measured. Multi-Class Receiver-Operator-Curve analyses were used to determine the predictive value of all variables and to define optimal cutoff-values. RESULTS: Differences between patients who underwent implantation of the small, medium or large prosthesis were significant for all except the large vs. medium CoreValve (all p's<0.05. Furthermore, mean diameter, annulus area and circumference had equally high predictive value for prosthesis size for both manufacturers (multi-class AUC's: 0.80, 0.88, 0.91, 0.88, 0.88, 0.89. Using the calculated optimal cutoff-values, prosthesis size is predicted correctly in 85% of cases. CONCLUSION: CT-based aortic root measurements permit excellent prediction of the prosthesis size considered optimal during TAVI.

  11. Rapid Two-stage Versus One-stage Surgical Repair of Interrupted Aortic Arch with Ventricular Septal Defect in Neonates

    Directory of Open Access Journals (Sweden)

    Meng-Lin Lee

    2008-11-01

    Conclusion: The outcome of rapid two-stage repair is comparable to that of one-stage repair. Rapid two-stage repair has the advantages of significantly shorter cardiopulmonary bypass duration and AXC time, and avoids deep hypothermic circulatory arrest. LVOTO remains an unresolved issue, and postoperative aortic arch restenosis can be dilated effectively by percutaneous balloon angioplasty.

  12. Defining degree of aortic occlusion for partial-REBOA: A computed tomography study on large animals.

    Science.gov (United States)

    Reva, Viktor A; Matsumura, Yosuke; Samokhvalov, Igor M; Pochtarnik, Alexander A; Zheleznyak, Igor S; Mikhailovskaya, Ekaterina M; Morrison, Jonathan J

    2018-04-20

    Partial resuscitative endovascular balloon occlusion of the aorta (P-REBOA) is a modified REBOA technique designed to help ameliorate ischemia-reperfusion injury. The balloon is partially deflated, allowing a proportion of aortic flow distal to the balloon. The aim of this study is to use an ovine model of haemorrhagic shock to correlate the degree of occlusion to several hemodynamic indices. Six sheep weighing 35-46 kg underwent a controlled venous haemorrhage inside a CT scanner until the systolic arterial pressure (AP) dropped to fashion (proximal: r 2  = 0.85, p trend (r 2  = 0.90, p < 0.001). The relationship between percentage occlusion and IBP was sigmoid. MAP values became significantly different at 40-49% occlusion and more (p < 0.01). Furthermore, a drop in the distal pulse pressure from 7.0 (5.5-16.5) to 2.0 (1.5-5.0) mmHg was observed at 80% occlusion. All animals had femoral pulse pressure <5 mmHg at 80% of occlusion and more, which also coincided with the observed loss of pulsatility of the femoral wave-form. Serial CT angiography at an ovine model of haemorrhagic shock demonstrates a correlation between the femoral MAP, F/C pressure gradient and degree of zone I P-REBOA during the staged partial aortic occlusion. These parameters should be considered potential parameters to define the degree of P-REBOA during animal research and clinical practice. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Long-term outcomes after immediate aortic repair for acute type A aortic dissection complicated by coma.

    Science.gov (United States)

    Tsukube, Takuro; Haraguchi, Tomonori; Okada, Yasushi; Matsukawa, Ritsu; Kozawa, Shuichi; Ogawa, Kyoichi; Okita, Yutaka

    2014-09-01

    The management of acute type A aortic dissection complicated by coma remains controversial. We previously reported an excellent rate of recovery of consciousness provided aortic repair was performed within 5 hours of the onset of symptoms. This study evaluates the early and long-term outcomes using this approach. Between August 2003 and July 2013, of the 241 patients with acute type A aortic dissection brought to the Japanese Red Cross Kobe Hospital and Hyogo Emergency Medical Center, 30 (12.4%) presented with coma; Glasgow Coma Scale was less than 11 on arrival. Surgery was performed in 186 patients, including 27 (14.5%) who were comatose. Twenty-four comatose patients underwent successful aortic repair immediately (immediate group). Their mean age was 71.0 ± 11.1 years, Glasgow Coma Scale was 6.5 ± 2.4, and prevalence of carotid dissection was 79%. For brain protection, deep hypothermia with antegrade cerebral perfusion was used, and postoperative induced hypothermia was performed. Neurologic evaluations were performed using the Glasgow Coma Scale, National Institutes of Health Stroke Scale, and modified Rankin Scale. In the immediate group, the time from the onset of symptoms to arrival in the operating theater was 222 ± 86 minutes. Hospital mortality was 12.5%. Full recovery of consciousness was achieved in 79% of patients in up to 30 days. Postoperative Glasgow Coma Scale and National Institutes of Health Stroke Scale improved significantly when compared with the preoperative score (P coma were satisfactory. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  14. Organizing Thrombus Mimicking a Cardiac Tumor Located at the Mitral-Aortic Intervalvular Fibrosa

    Directory of Open Access Journals (Sweden)

    Ji Seong Lee

    2016-02-01

    Full Text Available Thrombosis at the left ventricular outflow tract occurs without any detectable heart disease or predisposing factors only extremely rarely. A 48-year-old male visited Konkuk University Medical Center with loss of consciousness one month prior to presentation. Before he visited our hospital, he had been diagnosed with a cardiac tumor, which was located between the left atrium and posterior aortic root, and which was adjacent to both the aortic and mitral valves. Cardiac transplantation was recommended at the other hospital because of the high risk of cardiac dysfunction induced by both aortic and mitral valvular dysfunction after surgical resection. Based on preoperative transthoracic echocardiography, cardiac computed tomography, cardiac magnetic resonance imaging, and intraoperative transesophageal echocardiography, we considered it to be a benign tumor. Complete resection was achieved and the pathology confirmed organizing thrombus. We report a case of organizing thrombus mimicking a cardiac tumor, which was located at the mitral-aortic intervalvular fibrosa of the left ventricular outflow tract without any heart disease.

  15. Statin use is associated with reduced all-cause mortality after endovascular abdominal aortic aneurysm repair.

    NARCIS (Netherlands)

    Leurs, L.J.; Visser, P.; Laheij, R.J.F.; Buth, J.; Harris, P.L.; Blankensteijn, J.D.

    2006-01-01

    It has been shown that preoperative statin therapy reduces all-cause and cardiovascular mortality in patients undergoing major noncardiac vascular surgery. In this report, we investigated the influence of statin use on early and late outcome following endovascular abdominal aortic aneurysm repair

  16. Left ventricular function in patients with ventricular arrhythmias and aortic valve disease

    International Nuclear Information System (INIS)

    Santinga, J.T.; Kirsh, M.M.; Brady, T.J.; Thrall, J.; Pitt, B.

    1983-01-01

    Forty patients having aortic valve replacement were evaluated preoperatively for ventricular arrhythmia and left ventricular ejection fraction. Arrhythmias were classified as complex or simple using the Lown criteria on the 24-hour ambulatory electrocardiogram; ejection fractions were determined by radionuclide gated blood pool analysis and contrast angiography. The ejection fractions determined by radionuclide angiography were 59.1 +/- 13.1% for 26 patients with simple or no ventricular arrhythmias, and 43.9 +/- 20.3% for 14 patients with complex ventricular arrhythmias (p less than 0.01). Ejection fractions determined by angiography, available for 31 patients, were also lower in patients with complex ventricular arrhythmias (61.1 +/- 16.3% versus 51.4 +/- 13.4%; p less than 0.05). Seven of 9 patients showing conduction abnormalities on the electrocardiogram had complex ventricular arrhythmias. Eight of 20 patients with aortic stenosis had complex ventricular arrhythmias, while 2 of 13 patients with aortic insufficiency had such arrhythmias. It is concluded that decreased left ventricular ejection fraction, intraventricular conduction abnormalities, and aortic stenosis are associated with an increased frequency of complex ventricular arrhythmias in patients with aortic valve disease

  17. Preoperative estimation of tibial nail length--because size does matter.

    LENUS (Irish Health Repository)

    Galbraith, J G

    2012-11-01

    Selecting the correct tibial nail length is essential for satisfactory outcomes. Nails that are inserted and are found to be of inappropriate length should be removed. Accurate preoperative nail estimation has the potential to reduce intra-operative errors, operative time and radiation exposure.

  18. Transcranial magnetic stimulation in the semi-quantitative, pre-operative assessment of patients undergoing spinal deformity surgery.

    Science.gov (United States)

    Glasby, Michael A; Tsirikos, Athanasios I; Henderson, Lindsay; Horsburgh, Gillian; Jordan, Brian; Michaelson, Ciara; Adams, Christopher I; Garrido, Enrique

    2017-08-01

    To compare measurements of motor evoked potential latency stimulated either magnetically (mMEP) or electrically (eMEP) and central motor conduction time (CMCT) made pre-operatively in conscious patients using transcranial and intra-operatively using electrical cortical stimulation before and after successful instrumentation for the treatment of adolescent idiopathic scoliosis. A group initially of 51 patients with adolescent idiopathic scoliosis aged 12-19 years was evaluated pre-operatively in the outpatients' department with transcranial magnetic stimulation. The neurophysiological data were then compared statistically with intra-operative responses elicited by transcranial electrical stimulation both before and after successful surgical intervention. MEPs were measured as the cortically evoked compound action potentials of Abductor hallucis. Minimum F-waves were measured using conventional nerve conduction methods and the lower motor neuron conduction time was calculated and this was subtracted from MEP latency to give CMCT. Pre-operative testing was well tolerated in our paediatric/adolescent patients. No neurological injury occurred in any patient in this series. There was no significant difference in the values of mMEP and eMEP latencies seen pre-operatively in conscious patients and intra-operatively in patients under anaesthetic. The calculated quantities mCMCT and eCMCT showed the same statistical correlations as the quantities mMEP and eMEP latency. The congruency of mMEP and eMEP and of mCMCT and eCMCT suggests that these measurements may be used comparatively and semi-quantitatively for the comparison of pre-, intra-, and post-operative spinal cord function in spinal deformity surgery.

  19. Recovery from anemia in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation--prevalence, predictors and clinical outcome

    DEFF Research Database (Denmark)

    De Backer, Ole; Arnous, Samer; Lønborg, Jacob

    2014-01-01

    INTRODUCTION: Preoperative anemia is common in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI) and has been linked to a poorer outcome--including a higher 1-year mortality. The aim of this study was to investigate the impact of successful TAVI...... on baseline anemia. METHODS: A total of 253 patients who survived at least 1 year following TAVI were included in this study. The prevalence, predictors and clinical outcome of hemoglobin (Hb)-recovery were assessed. RESULTS: The prevalence of baseline anemia was 49% (n = 124)--recovery from anemia occurred......-recovery, while blood transfusion (OR 0.31, P = 0.038) and chronic kidney disease (CKD, OR 0.33, P = 0.043) were identified as negative predictors at, respectively, one and two years after TAVI. When compared to patients without baseline anemia, those anemic patients with Hb-recovery had a similar functional...

  20. The Effect of Intra-articular Cocktail Versus Femoral Nerve Block for Patients Undergoing Hip Arthroscopy.

    Science.gov (United States)

    Childs, Sean; Pyne, Sonia; Nandra, Kiritpaul; Bakhsh, Wajeeh; Mustafa, S Atif; Giordano, Brian D

    2017-12-01

    To compare clinical efficacy and complication rate as measured by postoperative falls and development of peripheral neuritis between intra-articular blockade and femoral nerve block in patients undergoing arthroscopic hip surgery. An institutional review board approved retrospective review was conducted on a consecutive series of patients who underwent elective arthroscopic hip surgery by a single surgeon, between November 2013 and April 2015. Subjects were stratified into 2 groups: patients who received a preoperative femoral nerve block for perioperative pain control, and patients who received an intra-articular "cocktail" injection postoperatively. Demographic data, perioperative pain scores, narcotic consumption, incidence of falls, and iatrogenic peripheral neuritis were collected for analysis. Postoperative data were then collected at routine clinical visits. A total of 193 patients were included in this study (65 males, 125 females). Of them, 105 patients received preoperative femoral nerve blocks and 88 patients received an intraoperative intra-articular "cocktail." There were no significant differences in patient demographics, history of chronic pain (P = .35), worker's compensation (P = .24), preoperative pain scores (P = .69), or intraoperative doses of narcotics (P = .40). Patients who received preoperative femoral nerve blocks reported decreased pain during their time in PACU (P = .0001) and on hospital discharge (P = .28); however, there were no statistically significant differences in patient-reported pain scores at postoperative weeks 1 (P = .34), 3 (P = .64), and 6 (P = .70). Administration of an intra-articular block was associated with a significant reduction in the rate of postoperative falls (P = .009) and iatrogenic peripheral neuritis (P = .0001). Preoperative femoral nerve blocks are associated with decreased immediate postoperative pain, whereas intraoperative intra-articular anesthetic injections provide effective postoperative

  1. A insuficiência da valva aórtica na dissecção crônica da aorta proximal: troca ou reconstrução valvar? Aortic valve insufficiency in chronic aortic dissection: valve replacement or reconstruction?

    Directory of Open Access Journals (Sweden)

    Ricardo Beyruti

    1993-06-01

    Full Text Available Com o objetivo de avaliar os resultados clínicos e ecocardiográficos tardios obtidos com a correção da insuficiência aórtica decorrente da dissecção crônica da aorta proximal, foram estudados 48 pacientes consecutivos operados entre janeiro de 1980 e dezembro de 1989, separados em 2 grupos de 24 pacientes cada. Grupo A - pacientes nos quais a valva aórtica foi preservada pela "resuspensão comissural"; Grupo B - pacientes nos quais a valva aórtica foi substituída. Na avaliação ecocardiográfica pré-operatória, os pacientes do Grupo B apresentavam grau de insuficiência aórtica, diâmetros ventriculares (sistólico e diastólico e da aorta ascendente significativamente maiores do que os do Grupo A (p=0,03, sendo comparáveis nos demais parâmetros. A mortalidade hospitalar foi 12,5% no Grupo A e de 4,17% no Grupo B e a sobrevida aos 7 anos, respectivamente, 75,75% ± 9,82% e 82,72% ± 7,87% (NS. A avaliação clínica mostrou que, no pós-operatório, houve melhora significativa (pFrom January 1980 to December 1989, 48 consecutive patients with chronic aortic dissection and aortic valve insufficiency underwent operation. They were analyzed in 2 groups (24 patients each to evaluate the late clinical and echocardiography outcome of those in whom the aortic valve was preserved (Group A compared with those having valve replacement (Group B. The overall preoperative characteristics of the two groups were similar except for the age (Group A 47.9 ± 10.8 versus Group B 40.2 ± 9.5 years, p=0.03. In the preoperative echocardiographic evaluation, Group B patients had significantly higher aortic root and left ventricle systolic and diastolic diameters (p<0.03, and aortic insufficiency grade (p=0.02. The hospital mortality was 12.5% in Group A and 4.2% in Group B and the seven years actuarial survival rate was respectively 75.7% ± 9.8% and 82.7% ± 7.9%. Postoperatively there was, in both groups, a significant improvement in all clinical

  2. Retroperitoneal aortic hemorrhage caused by penetration of an endovascular stent-graft anchoring barb.

    Science.gov (United States)

    Twine, Christopher P; Winterbottom, Andrew; Shaida, Nadeem; Boyle, Jonathan R

    2013-08-01

    To report a rare case of acute intraoperative retroperitoneal hemorrhage secondary to aortic penetration by the suprarenal anchoring barb on a stent-graft. A 75-year-old patient on dual antiplatelet therapy for coronary stents and low-molecular-weight heparin for atrial thrombus underwent elective endovascular repair of a 6.7-cm infrarenal abdominal aortic aneurysm. A device with suprarenal fixation and metal anchoring barbs was implanted, and a molding balloon was used that at no time covered the proximal bare metal stents or barbs. In recovery, the patient became tachycardic and hypotensive. After resuscitation, imaging identified an anterior barb penetrating the aortic wall, causing the acute retroperitoneal hemorrhage. A decision to treat conservatively rather than resort to open surgery was difficult but ultimately influenced by the patients' high risk for open surgery. The patient was treated by aggressive reversal of heparin and platelet transfusion, and the bleed settled spontaneously. Major surgery and subsequent morbidity may be avoided by medical management of what would appear to be a surgical problem.

  3. Expanding indications for valve-sparing aortic root reconstruction: early and midterm results.

    Science.gov (United States)

    Valo, Johanna; Jokinen, Janne J; Kaarne, Markku; Ihlberg, Leo

    2013-02-01

    Valve-sparing aortic root reconstruction (VSRR) is an accepted method to treat patients with aortic root dilation. The role of the VSRR is less well defined for patients with bicuspid aortic valve, severe aortic valve insufficiency, congenital heart defects, and type A aortic dissection. We studied the clinical outcome of patients who underwent VSRR for expanded indications. Seventy-eight patients underwent VSRR between the 2005 and 2012. Seventy-two patients (92%) underwent reimplantation and 6 patients (8%) were operated on with the remodeling technique. The mean age was 51 ± 12 years (range 24 to 73). For 71 patients (91%), the operation was elective, and for 7 (9%; all with type A aortic dissection), on an emergency basis. Preoperatively, the degree of aortic insufficiency was graded as 2+ or greater for 27 patients (35%). Connective tissue disorder (Marfan or Loeys-Dietz), bicuspid aortic valve, or congenital heart disease was present in 15 (19%), 15 (19%), and 7 patients (9%), respectively. Concomitant aortic valve leaflet repair was performed for 39 patients (50%). The mean follow-up time was 2.4 ± 1.7 years (range, 0.1 to 7.0). Thirty-day mortality was zero. The rate of postoperative complications was low: stroke 3%, renal failure 3%, prosthesis infection 1%, and low cardiac output syndrome 1%. Survival was 100% at 1 year and 97% at 5 years. Freedom from recurrent aortic valve insufficiency (≥2+) during the follow-up was 94%. The midterm results of VSRR in terms of survival, freedom from recurrent aortic valve insufficiency, and the need for reoperation are excellent, even for high-risk patients. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Abdominal aortic aneurysm calcification and thrombus volume are not associated with outcome following endovascular abdominal aortic aneurysm repair

    International Nuclear Information System (INIS)

    Rai, Divyajeet; Velu, Ramesh; Tosenovsky, Patrik; Quigley, Francis; Wisniowski, Brendan; Walker, Philip J.; Bradshaw, Barbara; Golledge, Jonathan

    2014-01-01

    Aortic calcification and thrombus have been postulated to worsen outcome following endovascular abdominal aortic aneurysm repair (EVAR). The purpose of this study was to assess the association of abdominal aortic aneurysm (AAA) calcification and thrombus volume with outcome following EVAR using a reproducible, quantifiable computed tomography (CT) assessment protocol. Patients with elective EVAR performed between January 2002 and 2012 at the Townsville Hospital, Mater Private Hospital (Townsville) and Royal Brisbane and Women's Hospital (RBWH) were included if preoperative CTAs were available for analysis. AAA calcification and thrombus volume were measured using a semiautomated workstation protocol. Outcomes were assessed in terms of clinical failure, endoleak (type I, type II) and reintervention. Univariate and multivariate analyses were performed. Median follow-up was 1.7 years and the interquartile range 1.0-3.8 years. One hundred thirty-four patients undergoing elective EVAR were included in the study. Rates of primary clinical success and freedom from reintervention were 82.8 % and 88.9 % at the 24-month follow-up. AAA calcification and thrombus volume were not associated with clinical failure, type I endoleak, type II endoleak or reintervention. AAA calcification and thrombus volume were not associated with poorer outcome after EVAR in this study. (orig.)

  5. Abdominal aortic aneurysm calcification and thrombus volume are not associated with outcome following endovascular abdominal aortic aneurysm repair

    Energy Technology Data Exchange (ETDEWEB)

    Rai, Divyajeet; Velu, Ramesh; Tosenovsky, Patrik; Quigley, Francis [James Cook University, Queensland Research Centre for Peripheral Vascular Disease, School of Medicine and Dentistry, Townsville, Queensland (Australia); The Townsville Hospital, Department of Vascular and Endovascular Surgery, Douglas (Australia); Wisniowski, Brendan; Walker, Philip J. [James Cook University, Queensland Research Centre for Peripheral Vascular Disease, School of Medicine and Dentistry, Townsville, Queensland (Australia); University of Queensland, School of Medicine and Centre for Clinical Research, Department of Vascular Surgery, Royal Brisbane and Women' s Hospital, Herston, QLD (Australia); Bradshaw, Barbara [James Cook University, Queensland Research Centre for Peripheral Vascular Disease, School of Medicine and Dentistry, Townsville, Queensland (Australia); Golledge, Jonathan [James Cook University, Queensland Research Centre for Peripheral Vascular Disease, School of Medicine and Dentistry, Townsville, Queensland (Australia); The Townsville Hospital, Department of Vascular and Endovascular Surgery, Douglas (Australia); University of Queensland, School of Medicine and Centre for Clinical Research, Department of Vascular Surgery, Royal Brisbane and Women' s Hospital, Herston, QLD (Australia)

    2014-08-15

    Aortic calcification and thrombus have been postulated to worsen outcome following endovascular abdominal aortic aneurysm repair (EVAR). The purpose of this study was to assess the association of abdominal aortic aneurysm (AAA) calcification and thrombus volume with outcome following EVAR using a reproducible, quantifiable computed tomography (CT) assessment protocol. Patients with elective EVAR performed between January 2002 and 2012 at the Townsville Hospital, Mater Private Hospital (Townsville) and Royal Brisbane and Women's Hospital (RBWH) were included if preoperative CTAs were available for analysis. AAA calcification and thrombus volume were measured using a semiautomated workstation protocol. Outcomes were assessed in terms of clinical failure, endoleak (type I, type II) and reintervention. Univariate and multivariate analyses were performed. Median follow-up was 1.7 years and the interquartile range 1.0-3.8 years. One hundred thirty-four patients undergoing elective EVAR were included in the study. Rates of primary clinical success and freedom from reintervention were 82.8 % and 88.9 % at the 24-month follow-up. AAA calcification and thrombus volume were not associated with clinical failure, type I endoleak, type II endoleak or reintervention. AAA calcification and thrombus volume were not associated with poorer outcome after EVAR in this study. (orig.)

  6. Successful management of aortic thrombi resulting in spinal cord infarction in a patient with antiphospholipid antibody syndrome and acute cholecystitis

    Directory of Open Access Journals (Sweden)

    Izumi M

    2011-12-01

    Full Text Available Manabu Izumi, Shoko Teraoka, Keisuke Yamashita, Kenji Matsumoto, Tomohiro Muronoi, Yoshimitsu Izawa, Chikara Yonekawa, Masaki Ano, Masayuki SuzukawaDepartment of Emergency and Critical Care Medicine, Jichi Medical University, Tochigi, JapanAbstract: A 74-year-old man with coronary artery disease was suffering from acute nonobstructive cholecystitis and was admitted to a nearby hospital. Dual antiplatelet (aspirin and ticlopidine therapy was discontinued before preparation for surgical resection of the gall bladder. During his time in hospital he was aware of lumbar pain and weakness in both legs. He was transferred to our hospital for further evaluation and therapy. Diffuse intra-aortic thrombi were revealed by computed tomography with contrast media, and magnetic resonance imaging showed spinal cord infarction. However, computed tomography scans of the descending aorta obtained 4 months before admission exhibited no signs of atherosclerotic plaques or intra-aortic thrombi. Laboratory data suggest that antiphospholipid antibody syndrome might have caused these acute multiple intra-arterial thrombi. By restarting dual antiplatelet therapy and increasing the dose of heparin (from 10,000 IU/day to 15,000 IU/day we successfully managed the patient's clinical condition and symptoms. It is important to understand that stopping antiplatelet therapy may rapidly grow thrombi in patients with a hypercoagulative state.Keywords: intra-aortic thrombus, antiphospholipid antibody syndrome, spinal cord infarction

  7. The Inflammatory Sequelae of Aortic Balloon Occlusion in Hemorrhagic Shock

    Science.gov (United States)

    2014-04-13

    respectively. There was a trend toward greater vasopressor use (P ¼ 0.183) and increased incidence of acute respiratory distress syndrome (P ¼ 0.052) across the...Jansen JO. Intra operative correction of acidosis , coagulopathy and hypothermia in combat casualties with severe haemorrhagic shock. Anaesthesia...noncompressible torso hemorrhage. J Trauma 2011;71:S131. [19] Ranieri VM, Rubenfeld GD, Thompson BT, et al. Acute respiratory distress syndrome: the

  8. Single-center experience using the Freedom SOLO aortic bioprosthesis.

    Science.gov (United States)

    Iliopoulos, Dimitrios C; Deveja, Aris Rezar; Androutsopoulou, Vasiliki; Filias, Vasilios; Kastelanos, Eleftherios; Satratzemis, Vasilios; Khalpey, Zain; Koudoumas, Dimitrios

    2013-07-01

    This study reviews a single institution experience with the Freedom SOLO (Sorin Group, Saluggia, Italy) aortic bioprosthesis. Between October 2006 and February 2010, 128 patients (64 men, 64 women; mean age, 75.8 ± 5.1 years) underwent aortic valve replacement using the Freedom SOLO stentless aortic valve. The follow-up time was 36.7 ± 1.2 months and 100% complete. Concomitant procedures were performed in 77 patients (60%). The mean standard European System for Cardiac Operative Risk Evaluation was 9 ± 2.7. Grade 3 aortic stenosis was present in 73% of patients, mixed aortic stenosis and regurgitation were present in 40% of patients, and mitral regurgitation was present in 46% of patients. The mean crossclamp time was 53 ± 12 minutes for isolated Freedom SOLO aortic valve implantation and 80 ± 28 minutes for concomitant procedures, and the mean cardiopulmonary bypass time was 103 ± 31 minutes. The mean implanted valve size was 22.6 ± 1.4 mm. The mean intensive care unit and hospital stays were 2.4 ± 1.1 days and 8.8 ± 2.6 days, respectively. Three patients underwent reoperation for bleeding. The 15-day, 30-day, and perioperative mortality were all 4.6%. The 36-month survival was 95.4% ± 1.6% for the cohort with a low European System for Cardiac Operative Risk Evaluation (9). Echocardiographic data preoperatively, immediately postoperatively, and at 3, 6, and 12 months postoperatively showed peak transvalvular gradients of 75 ± 23, 17 ± 6, 18 ± 6.5, 16 ± 6, and 16 ± 9 mm Hg, respectively (P SOLO stentless aortic valve has excellent early and intermediate-term results. Published by Mosby, Inc.

  9. GHOST balloons around Antarctica

    Science.gov (United States)

    Stearns, Charles R.

    1988-01-01

    The GHOST balloon position as a function of time data shows that the atmospheric circulation around the Antarctic Continent at the 100 mb and 200 mb levels is complex. The GHOST balloons supposedly follow the horizontal trajectory of the air at the balloon level. The position of GHOST balloon 98Q for a three month period in 1968 is shown. The balloon moved to within 2 deg of the South Pole on 1 October 1968 and then by 9 December 1968 was 35 deg from the South Pole and close to its position on 1 September 1968. The balloon generally moved from west to east but on two occasions moved in the opposite direction for a few days. The latitude of GHOST balloons 98Q and 149Z which was at 200 mb is given. Both balloons tended to get closer to the South Pole in September and October. Other GHOST balloons at the same pressure and time period may not indicate similar behavior.

  10. Preoperative irradiation of hypernephroid carcinoma

    International Nuclear Information System (INIS)

    Akbar, D.

    1982-01-01

    Since 1969, preoperative irradiation of hypernephiroid carcinoma has been a routine measure at the Steglitz medical clinic: It consists in the application of a focal dose of 30 Gy, fractionated into doses of 2.5 Gy, as Betatron pendulum irradiation (42 MeV photons) covering the para-aortic lymph nodes. After a treatment-free interval of 3 weeks, radical nephrectomy is carried through. Of 178 patients, 47 were in tumor stage I, 15 in stage II, 83 in stage III and 33 in stage IV. In 99 patients the treatment dated back longer than 5 years; the survival rate was 52%. 67% of the patients had survived longer than 3 years. Operation lethality was 3%. The preoperative irradiation pursues the following aims: 1. Devitalization of potentially proliferating cells in the tumor periphery, and thus prevention of displaced tumor cells growing on and postoperative local recidivations; 2. Shrinking of the tumor, facilitating the surgical intervention. In a third of the cases a measurable alteration of the tumor was confirmed by X-ray. The low operation lethality of 3% is attributed to this. (orig./MG) [de

  11. Implante transapical de endoprótese valvada balão-expansível em posição aórtica sem circulação extracorpórea Off-pump transapical balloon-expandable aortic valve endoprosthesis implantation

    Directory of Open Access Journals (Sweden)

    Diego Felipe Gaia

    2009-06-01

    ão.OBJECTIVE: The aortic valve replacement is a routine procedure, and involves replacement of the native valve/prosthesis. In most of the patients who undergo such procedure the risk is acceptable, but in some cases, such risk can justify contraindication. The minimally invasive transcatheter aortic valve implantation without cardiopulmonary bypass (CPB has been shown to be viable, with lower morbidity and mortality. The aim of this study was to develop a catheter-mounted aortic bioprosthesis for implantation without CPB. METHODS: After developing in animals, three patients with high EuroSCORE underwent implantation. Case 1: patients with bioprosthesis dysfunction; Case 2: severe aortic stenosis; Case 3: dysfunction of aortic bioprosthesis. After minithoracotomy and under echocardiographic and fluoroscopic control, a balloon catheter was placed on aortic position and inflated. After, a second balloon with valved endoprosthesis was positioned and released under high ventricular rate. Echocardiographic and angiographic controls were performed and the patients were referred to ICU. RESULTS: In the first case, implantation without CPB was possible with appropriate results. The patient evolved with improvement of ventricular function. After, this patient developed bronchopneumonia, tracheoesophageal fistula and died due to mediastinitis. Autopsy confirmed proper valve positioning and leaflets preservation. The second case showed the device migration after inflation of the balloon, with the need for urgent median sternotomy, CPB and conventional valve replacement. This patient evolved well and was discharged from the ICU on the 14th postoperative day without complications. This patient developed respiratory infection, septic shock and died on the 60th postoperative day. The patient from the third case underwent successful implantation. CONCLUSION: The off-pump transapical implantation of catheter-mounted bioprosthesis was shown to be a feasible procedure. Technical details and learning

  12. Anesthetic management of cesarean section in cases of placenta accreta, with versus without abdominal aortic balloon occlusion: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Chu, Qinjun; Shen, Dan; He, Long; Wang, Hongwei; Zhao, Xianlan; Chen, Zhimin; Wang, Yanli; Zhang, Wei

    2017-05-26

    Placenta accreta (PA), a severe complication during delivery, is closely linked with massive hemorrhage which could endanger the lives of both mother and baby. Moreover, the incidence of PA has increased dramatically with the increasing rate of cesarean deliveries in the past few decades. Therefore, studies evaluating the effects of different perioperative managements based on different modalities in the treatment of PA are necessary. Among the numerous treatment measures, prophylactic abdominal aortic balloon occlusion (AABO) in combination with cesarean section for PA seems to be more advantageous than others. However, up to now, all studies on AABO were almost retrospective. Current evidence is insufficient to recommend for or against routinely using the AABO technology for control intraoperative hemorrhage in patients with PA. Thus, we hope to carry out a prospective, randomized controlled trial (RCT) study to confirm the effectiveness of the AABO technology in patients with PA. This trial is an investigator-initiated, prospective RCT that will test the superiority of AABO in combination with cesarean section compared to the traditional hysterectomy following cesarean section for parturients with PA. A total of 170 parturients with PA undergoing cesarean section will be randomized to receive either AABO in combination with cesarean section or the traditional hysterectomy following cesarean section. The primary outcome is estimated blood loss. The most important secondary outcome is the occurrence of cesarean hysterectomy during delivery; others include blood transfusion volume, operating time, neonate's Apgar scores (collected at 1, 5 and 10 min), length of stay in intensive care unit, total hospital stay, and balloon occlusion-relative data. This prospective trial will test the superiority of AABO in combination with cesarean section compared to the traditional hysterectomy following cesarean section for parturients with PA. It may provide strong evidence

  13. Scan-rescan reproducibility of segmental aortic wall shear stress as assessed by phase-specific segmentation with 4D flow MRI in healthy volunteers.

    Science.gov (United States)

    van der Palen, Roel L F; Roest, Arno A W; van den Boogaard, Pieter J; de Roos, Albert; Blom, Nico A; Westenberg, Jos J M

    2018-05-26

    The aim was to investigate scan-rescan reproducibility and observer variability of segmental aortic 3D systolic wall shear stress (WSS) by phase-specific segmentation with 4D flow MRI in healthy volunteers. Ten healthy volunteers (age 26.5 ± 2.6 years) underwent aortic 4D flow MRI twice. Maximum 3D systolic WSS (WSSmax) and mean 3D systolic WSS (WSSmean) for five thoracic aortic segments over five systolic cardiac phases by phase-specific segmentations were calculated. Scan-rescan analysis and observer reproducibility analysis were performed. Scan-rescan data showed overall good reproducibility for WSSmean (coefficient of variation, COV 10-15%) with moderate-to-strong intraclass correlation coefficient (ICC 0.63-0.89). The variability in WSSmax was high (COV 16-31%) with moderate-to-good ICC (0.55-0.79) for different aortic segments. Intra- and interobserver reproducibility was good-to-excellent for regional aortic WSSmax (ICC ≥ 0.78; COV ≤ 17%) and strong-to-excellent for WSSmean (ICC ≥ 0.86; COV ≤ 11%). In general, ascending aortic segments showed more WSSmax/WSSmean variability compared to aortic arch or descending aortic segments for scan-rescan, intraobserver and interobserver comparison. Scan-rescan reproducibility was good for WSSmean and moderate for WSSmax for all thoracic aortic segments over multiple systolic phases in healthy volunteers. Intra/interobserver reproducibility for segmental WSS assessment was good-to-excellent. Variability of WSSmax is higher and should be taken into account in case of individual follow-up or in comparative rest-stress studies to avoid misinterpretation.

  14. Percutaneous balloon valvuloplasty in mitral stenosis

    International Nuclear Information System (INIS)

    Park, Jae Hyung; Oh, Byung Hee; Park, Kyung Ju; Kim, Seung Hyup; Lee, Young Woo; Han, Man Chung

    1989-01-01

    Percutaneous balloon valvuloplasty(PBV) was successfully performed in 8 mitral stenosis patients for recent 3 months. Five patients have aortic insufficiencies also and two patients have mitral regurgitations below grade II/IV. All patients showed sinus rhythm on EKG, and had no mitral valvular calcification on echocardiography and fluoroscopy. PBV resulted in an increase in mitral valve area from 1.22±0.22 to 2.57±0.86 cm 2 , a decrease in mean left atrial pressure from 23.4±9.6 to 7.5±3.4 mmHg and a decrease in mean mitral pressure gradient from 21.3±9.4 to 6.8±3.1 mmHg. There were no significant complications except 2 cases of newly appeared and mildly aggravated mitral regurgitation. We believe that PBV will become a treatment modality of choice replacing surgical commissurotomy or valve replacement in a group of mitral stenosis patients, because of its effectiveness and safety

  15. Appropriateness of Intra-Operative Blood Transfusion In Children at ...

    African Journals Online (AJOL)

    Background: The decision to transfuse intra-operatively is based on preoperative haemoglobin (Hb), estimated blood loss and physiological variables. The visual estimate of blood loss is notoriously unreliable especially with small volumes of blood losses in children. Objectives :We sought therefore to determine the ...

  16. Synchronized epiaortic two-dimensional and color Doppler echocardiographic guidance enables routine ascending aortic cannulation in type A acute aortic dissection.

    Science.gov (United States)

    Inoue, Yoshito; Takahashi, Ryuichi; Ueda, Toshihiko; Yozu, Ryohei

    2011-02-01

    Preference for arterial inflow during surgery for type A acute aortic dissection remains controversial. Antegrade central perfusion prevents malperfusion and retrograde embolism, and the ascending aorta provides arterial access for rapid establishment of systemic perfusion, especially if there is hemodynamic instability. It has not been used routinely, however, because of the disruption caused to the aorta. We evaluated the safety and efficacy of routine cannulation of the dissected aorta for the repair of type A dissection. Surgical results were analyzed for 83 consecutive patients with type A acute aortic dissection between 2002 and 2009. They were treated surgically by prosthetic graft replacement under hypothermic circulatory arrest. The ascending aorta was routinely cannulated using the Seldinger technique with epiaortic echocardiographic guidance; antegrade systemic perfusion was evaluated by color Doppler ultrasound. Systemic antegrade perfusion via the dissected ascending aorta was performed safely in all cases. There was no malperfusion or thromboembolism as a result of ascending aortic cannulation. Epiaortic 2-dimensional and color Doppler imaging provided real-time monitoring adequate for the placement and for proper systemic perfusion. There were 5 in-hospital deaths (5/83=6.0%) and 8 strokes (preoperative 6/83=7.2%, postoperative 2/83=2.4%). A total of 78 patients (78/83=94%) were discharged and have been followed up without major adverse cardiac events for a mean duration of 31.8 months. Ascending aortic cannulation is a simple and safe technique that provides a rapid and reliable route of antegrade central systemic perfusion in type A aortic dissection. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  17. Cost-Effectiveness of Transcatheter Aortic Valve Replacement With a Self-Expanding Prosthesis Versus Surgical Aortic Valve Replacement.

    Science.gov (United States)

    Reynolds, Matthew R; Lei, Yang; Wang, Kaijun; Chinnakondepalli, Khaja; Vilain, Katherine A; Magnuson, Elizabeth A; Galper, Benjamin Z; Meduri, Christopher U; Arnold, Suzanne V; Baron, Suzanne J; Reardon, Michael J; Adams, David H; Popma, Jeffrey J; Cohen, David J

    2016-01-05

    Previous studies of the cost-effectiveness of transcatheter aortic valve replacement (TAVR) have been based primarily on a single balloon-expandable system. The goal of this study was to evaluate the cost-effectiveness of TAVR with a self-expanding prosthesis compared with surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis and high surgical risk. We performed a formal economic analysis on the basis of individual, patient-level data from the CoreValve U.S. High Risk Pivotal Trial. Empirical data regarding survival and quality of life over 2 years, and medical resource use and hospital costs through 12 months were used to project life expectancy, quality-adjusted life expectancy, and lifetime medical costs in order to estimate the incremental cost-effectiveness of TAVR versus SAVR from a U.S. Relative to SAVR, TAVR reduced initial length of stay an average of 4.4 days, decreased the need for rehabilitation services at discharge, and resulted in superior 1-month quality of life. Index admission and projected lifetime costs were higher with TAVR than with SAVR (differences $11,260 and $17,849 per patient, respectively), whereas TAVR was projected to provide a lifetime gain of 0.32 quality-adjusted life-years ([QALY]; 0.41 LY) with 3% discounting. Lifetime incremental cost-effectiveness ratios were $55,090 per QALY gained and $43,114 per LY gained. Sensitivity analyses indicated that a reduction in the initial cost of TAVR by ∼$1,650 would lead to an incremental cost-effectiveness ratio <$50,000/QALY gained. In a high-risk clinical trial population, TAVR with a self-expanding prosthesis provided meaningful clinical benefits compared with SAVR, with incremental costs considered acceptable by current U.S. With expected modest reductions in the cost of index TAVR admissions, the value of TAVR compared with SAVR in this patient population would become high. (Safety and Efficacy Study of the Medtronic CoreValve System in the Treatment of

  18. Midterm outcome of valve-sparing aortic root replacement in inherited connective tissue disorders.

    Science.gov (United States)

    Tanaka, Hiroshi; Ogino, Hitoshi; Matsuda, Hitoshi; Minatoya, Kenji; Sasaki, Hiroaki; Iba, Yutaka

    2011-11-01

    This study determined the midterm outcome of valve-sparing aortic root replacement for patients with inherited connective tissue disorders. From 1993 to 2008, 94 patients underwent valve-sparing aortic root replacement. Sixty patients (64%), average age 33 years (range, 15 to 61 years), had inherited connective tissue disorders: Marfan syndrome, 54 (92%); Loeys-Dietz syndrome, 5 (8%); and smooth muscle α-actin (ACTA2) mutation in 1. Median preoperative sinus diameter was 52 mm (range, 42 to 76 mm), and moderate/severe aortic regurgitation was present in 14 (23%). Seven (12%, 1993 to 1999) underwent remodeling procedures, and 53 had reimplantation procedures. Cusp repair was performed in 4. Median follow-up was 55 months (range, 1 to 149 months). There were 15 patients in the early term (1993 to 2000) and 45 in the late term (2001 to 2008). Four late deaths occurred (cardiac, 3; aortic, 1), with 10-year survival of 86%. Rates of freedom from aortic valve replacement at 5 and 10 years were 85% and 58% in remodeling and 96% and 58% in reimplantation. Risk factors for reoperations were postprocedure intraoperative aortic insufficiency greater than mild (p = 0.046), remodeling procedure (p = 0.016), and early term (p = 0.0002). One patient (2%) with none/trivial postprocedure aortic insufficiency required aortic valve replacement. Freedom from reoperation in patients with none/trivial postprocedure aortic insufficiency at 5 and 10 years was 100% and 67%. Meticulous control of aortic insufficiency during operation would bring favorable midterm durability in valve-sparing aortic root replacement using a reimplantation technique, even in patients with inherited connective tissue disorders. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Resuscitative Endovascular Balloon Occlusion of the Aorta and Resuscitative Thoracotomy in Select Patients with Hemorrhagic Shock: Early Results from the American Association for the Surgery of Trauma's Aortic Occlusion in Resuscitation for Trauma and Acute Care Surgery Registry.

    Science.gov (United States)

    Brenner, Megan; Inaba, Kenji; Aiolfi, Alberto; DuBose, Joseph; Fabian, Timothy; Bee, Tiffany; Holcomb, John B; Moore, Laura; Skarupa, David; Scalea, Thomas M

    2018-05-01

    Aortic occlusion is a potentially valuable tool for early resuscitation in patients nearing extremis or in arrest from severe hemorrhage. The American Association for the Surgery of Trauma's Aortic Occlusion in Resuscitation for Trauma and Acute Care Surgery registry identified trauma patients without penetrating thoracic injury undergoing aortic occlusion at the level of the descending thoracic aorta (resuscitative thoracotomy [RT] or zone 1 resuscitative endovascular balloon occlusion of the aorta [REBOA]) in the emergency department (ED). Survival outcomes relative to the timing of CPR need and admission hemodynamic status were examined. Two hundred and eighty-five patients were included: 81.8% were males, with injury due to penetrating mechanisms in 41.4%; median age was 35.0 years (interquartile range 29 years) and median Injury Severity Score was 34.0 (interquartile range 18). Resuscitative thoracotomy was used in 71%, and zone 1 REBOA in 29%. Overall survival beyond the ED was 50% (RT 44%, REBOA 63%; p = 0.004) and survival to discharge was 5% (RT 2.5%, REBOA 9.6%; p = 0.023). Discharge Glasgow Coma Scale score was 15 in 85% of survivors. Prehospital CPR was required in 60% of patients with a survival beyond the ED of 37% and survival to discharge of 3% (all p > 0.05). Patients who did not require any CPR before had a survival beyond the ED of 70% (RT 48%, REBOA 93%; p American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Aortic root operations for Marfan syndrome: a comparison of the Bentall and valve-sparing procedures.

    Science.gov (United States)

    Patel, Nishant D; Weiss, Eric S; Alejo, Diane E; Nwakanma, Lois U; Williams, Jason A; Dietz, Harry C; Spevak, Philip J; Gott, Vincent L; Vricella, Luca A; Cameron, Duke E

    2008-06-01

    We compared results of the Bentall procedure with valve-sparing aortic root replacement (VSRR) for aortic root aneurysm in Marfan syndrome. Marfan syndrome patients who had the Bentall procedure or VSRR at our institution between April 1997 and September 2006 were identified. Follow-up information was obtained from hospital charts and contact with patients or their physicians. Kaplan-Meier survival and propensity score analyses were performed. One hundred forty Marfan syndrome patients had either the Bentall procedure (n = 56) or VSRR (n = 84; 40 remodeling and 44 reimplantation). Bentall patients were older than VSRR patients (38 versus 29 years; p = 0.0001) and had more aortic dissections (16% versus 1%; p = 0.0012); more urgent/emergent surgery (20% versus 2%; p = 0.0008); larger preoperative sinus diameter (5.7 versus 5.1 cm; p = 0.0004); and more preoperative 3+/4+ aortic insufficiency (59% versus 10%; p valve replacement was 90% for VSRR patients. Eight-year survival was 90% for Bentall and 100% for VSRR patients (p = 0.01). Propensity-adjusted regression showed that the Bentall procedure did not predict mortality (p = 1.00) and did not protect from reoperation (odds ratio = 0.28; 95% confidence interval: 0.01 to 4.33; p = 0.36). The Bentall procedure and VSRR have similar operative results in Marfan syndrome. The procedures are distinguished by higher rates of thromboembolism among Bentall patients and higher rates of reoperation among VSRR patients. Lower late survival among Bentall patients probably reflects the preferential use of the Bentall procedure for higher risk patients.

  1. Balloon-assisted enteroscopy for suspected Meckel’s diverticulum and indefinite diagnostic imaging workup

    Science.gov (United States)

    Gomes, Guilherme Francisco; Bonin, Eduardo Aimore; Noda, Rafael William; Cavazzola, Leandro Totti; Bartholomei, Thiago Ferreira

    2016-01-01

    Meckel’s diverticulum (MD) is estimated to affect 1%-2% of the general population, and it represents a clinically silent finding of a congenital anomaly in up to 85% of the cases. In adults, MD may cause symptoms, such as overt occult lower gastrointestinal bleeding. The diagnostic imaging workup includes computed tomography scan, magnetic resonance imaging enterography, technetium 99m scintigraphy (99mTc) using either labeled red blood cells or pertechnetate (known as the Meckel’s scan) and angiography. The preoperative detection rate of MD in adults is low, and many patients ultimately undergo exploratory laparoscopy. More recently, however, endoscopic identification of MD has been possible with the use of balloon-assisted enteroscopy via direct luminal access, which also provides visualization of the diverticular ostium. The aim of this study was to review the diagnosis by double-balloon enteroscopy of 4 adults with symptomatic MD but who had negative diagnostic imaging workups. These cases indicate that balloon-assisted enteroscopy is a valuable diagnostic method and should be considered in adult patients who have suspected MD and indefinite findings on diagnostic imaging workup, including negative Meckel’s scan. PMID:27803776

  2. Safe surgery: how accurate are we at predicting intra-operative blood loss?

    LENUS (Irish Health Repository)

    2012-02-01

    Introduction Preoperative estimation of intra-operative blood loss by both anaesthetist and operating surgeon is a criterion of the World Health Organization\\'s surgical safety checklist. The checklist requires specific preoperative planning when anticipated blood loss is greater than 500 mL. The aim of this study was to assess the accuracy of surgeons and anaesthetists at predicting intra-operative blood loss. Methods A 6-week prospective study of intermediate and major operations in an academic medical centre was performed. An independent observer interviewed surgical and anaesthetic consultants and registrars, preoperatively asking each to predict expected blood loss in millilitre. Intra-operative blood loss was measured and compared with these predictions. Parameters including the use of anticoagulation and anti-platelet therapy as well as intra-operative hypothermia and hypotension were recorded. Results One hundred sixty-eight operations were included in the study, including 142 elective and 26 emergency operations. Blood loss was predicted to within 500 mL of measured blood loss in 89% of cases. Consultant surgeons tended to underestimate blood loss, doing so in 43% of all cases, while consultant anaesthetists were more likely to overestimate (60% of all operations). Twelve patients (7%) had underestimation of blood loss of more than 500 mL by both surgeon and anaesthetist. Thirty per cent (n = 6\\/20) of patients requiring transfusion of a blood product within 24 hours of surgery had blood loss underestimated by more than 500 mL by both surgeon and anaesthetist. There was no significant difference in prediction between patients on anti-platelet or anticoagulation therapy preoperatively and those not on the said therapies. Conclusion Predicted intra-operative blood loss was within 500 mL of measured blood loss in 89% of operations. In 30% of patients who ultimately receive a blood transfusion, both the surgeon and anaesthetist significantly underestimate

  3. Energy from solar balloons

    Energy Technology Data Exchange (ETDEWEB)

    Grena, Roberto [C. R. Casaccia, via Anguillarese 301, 00123 Roma (Italy)

    2010-04-15

    Solar balloons are hot air balloons in which the air is heated directly by the sun, by means of a black absorber. The lift force of a tethered solar balloon can be used to produce energy by activating a generator during the ascending motion of the balloon. The hot air is then discharged when the balloon reaches a predefined maximum height. A preliminary study is presented, along with an efficiency estimation and some considerations on possible realistic configurations. (author)

  4. Colombian experience with transcatheter aortic valve implantation of medtronic CoreValve.

    Science.gov (United States)

    Dager, Antonio E; Nuis, Rutger-Jan; Caicedo, Bernardo; Fonseca, Jaime A; Arana, Camilo; Cruz, Lidsa; Benitez, Luis M; Nader, Carlos A; Duenas, Eduardo; de Marchena, Eduardo J; O'Neill, William W; de Jaegere, Peter P

    2012-01-01

    At our institutions, increasing numbers of aortic stenosis patients were not candidates for surgical aortic valve replacement. Accordingly, we initiated the Cali Colombian Transcatheter Aortic Valve Implantation (TAVI) program. From March 2008 through January 2011, 53 consecutive patients (mean age, 79 ± 6 yr; men, 58%) underwent TAVI with the Medtronic CoreValve System, and data were prospectively collected. Our study's endpoints conformed with Valve Academic Research Consortium recommendations. We report our clinical results.Predicted mortality rates were 25% (interquartile range, 17%-34%) according to logistic EuroSCORE and 6% (interquartile range, 3%-8%) according to the Society of Thoracic Surgeons score. The 30-day mortality rate was 9% (3 intraprocedural deaths, 5 total). The combined 30-day safety endpoint was 30% (major vascular sequelae, 23%; life-threatening bleeding, 12%; myocardial infarction, 4%; major stroke, 4%; and acute kidney injury [stage 3], 2%). Eight patients (15%) required post-implantation balloon dilation and 2 (4%) required valve-in-valve implantation, for a technical device success rate of 77%. Mean peak transvalvular gradient decreased from 74 ± 29 to 17 ± 8 mmHg and mean transvalvular gradient from 40 ± 17 to 8 ± 4 mmHg (both P=0.001). Moderate or severe aortic regurgitation decreased from 32% to 18% (P=0.12) and mitral regurgitation from 32% to 13% (P=0.002). The 1-year survival rate was 81%.We found that TAVI with the CoreValve prosthesis was safe and feasible, with sustained long-term results, for treating aortic stenosis in patients at excessive surgical risk; nonetheless, serious adverse events occurred in 30% of the patients.

  5. An integrated fluid-chemical model towards modeling the formation of intra-luminal thrombus in abdominal aortic aneurysms

    Directory of Open Access Journals (Sweden)

    Jacopo eBiasetti

    2012-07-01

    Full Text Available Abdominal Aortic Aneurysms (AAAs are frequently characterized by the presenceof an Intra-Luminal Thrombus (ILT known to influence biochemically and biomechanicallytheir evolution. ILT progression mechanism is still unclear and little is known regardingthe impact on this mechanism of the chemical species transported by blood flow.Chemical agonists and antagonists of platelets activation, aggregation, and adhesion andthe proteins involved in the coagulation cascade (CC may play an important role in ILTdevelopment. Starting from this assumption, the evolution of chemical species involvedin the CC, their relation to coherent vortical structures (VSs and their possible effect onILT evolution have been studied. To this end a fluido-chemical model that simulates theCC through a series of convection-diffusion-reaction (CDR equations has been developed.The model involves plasma-phase and surface bound enzymes and zymogens, and includesboth plasma-phase and membrane-phase reactions. Blood is modeled as a non-Newtonianincompressible fluid. VSs convect thrombin in the domain and lead to the high concentration observed in the distal portion of the AAA. This finding is in line with the clinicalobservations showing that the thickest ILT is usually seen in the distal AAA region. Theproposed model, due to its ability to couple the fluid and chemical domains, provides anintegrated mechanochemical picture that potentially could help unveil mechanisms of ILTformation and development.

  6. An integrated fluid-chemical model toward modeling the formation of intra-luminal thrombus in abdominal aortic aneurysms.

    Science.gov (United States)

    Biasetti, Jacopo; Spazzini, Pier Giorgio; Swedenborg, Jesper; Gasser, T Christian

    2012-01-01

    Abdominal Aortic Aneurysms (AAAs) are frequently characterized by the presence of an Intra-Luminal Thrombus (ILT) known to influence their evolution biochemically and biomechanically. The ILT progression mechanism is still unclear and little is known regarding the impact of the chemical species transported by blood flow on this mechanism. Chemical agonists and antagonists of platelets activation, aggregation, and adhesion and the proteins involved in the coagulation cascade (CC) may play an important role in ILT development. Starting from this assumption, the evolution of chemical species involved in the CC, their relation to coherent vortical structures (VSs) and their possible effect on ILT evolution have been studied. To this end a fluid-chemical model that simulates the CC through a series of convection-diffusion-reaction (CDR) equations has been developed. The model involves plasma-phase and surface-bound enzymes and zymogens, and includes both plasma-phase and membrane-phase reactions. Blood is modeled as a non-Newtonian incompressible fluid. VSs convect thrombin in the domain and lead to the high concentration observed in the distal portion of the AAA. This finding is in line with the clinical observations showing that the thickest ILT is usually seen in the distal AAA region. The proposed model, due to its ability to couple the fluid and chemical domains, provides an integrated mechanochemical picture that potentially could help unveil mechanisms of ILT formation and development.

  7. Valve thrombosis following transcatheter aortic valve implantation: a systematic review.

    Science.gov (United States)

    Córdoba-Soriano, Juan G; Puri, Rishi; Amat-Santos, Ignacio; Ribeiro, Henrique B; Abdul-Jawad Altisent, Omar; del Trigo, María; Paradis, Jean-Michel; Dumont, Eric; Urena, Marina; Rodés-Cabau, Josep

    2015-03-01

    Despite the rapid global uptake of transcatheter aortic valve implantation, valve trombosis has yet to be systematically evaluated in this field. The aim of this study was to determine the clinical characteristics, diagnostic criteria, and treatment outcomes of patients diagnosed with valve thrombosis following transcatheter aortic valve implantation through a systematic review of published data. Literature published between 2002 and 2012 on valve thrombosis as a complication of transcatheter aortic valve implantation was identified through a systematic electronic search. A total of 11 publications were identified, describing 16 patients (mean age, 80 [5] years, 65% men). All but 1 patient (94%) received a balloon-expandable valve. All patients received dual antiplatelet therapy immediately following the procedure and continued to take either mono- or dual antiplatelet therapy at the time of valve thrombosis diagnosis. Valve thrombosis was diagnosed at a median of 6 months post-procedure, with progressive dyspnea being the most common symptom. A significant increase in transvalvular gradient (from 10 [4] to 40 [12] mmHg) was the most common echocardiographic feature, in addition to leaflet thickening. Thrombus was not directly visualized with echocardiography. Three patients underwent valve explantation, and the remaining received warfarin, which effectively restored the mean transvalvular gradient to baseline within 2 months. Systemic embolism was not a feature of valve thrombosis post-transcatheter aortic valve implantation. Although a rare, yet likely under-reported complication of post-transcatheter aortic valve implantation, progressive dyspnea coupled with an increasing transvalvular gradient on echocardiography within the months following the intervention likely signifies valve thrombosis. While direct thrombus visualization appears difficult, prompt initiation of oral anticoagulation therapy effectively restores baseline valve function. Copyright © 2014

  8. Stunning and Right Ventricular Dysfunction Is Induced by Coronary Balloon Occlusion and Rapid Pacing in Humans: Insights From Right Ventricular Conductance Catheter Studies.

    Science.gov (United States)

    Axell, Richard G; Giblett, Joel P; White, Paul A; Klein, Andrew; Hampton-Til, James; O'Sullivan, Michael; Braganza, Denise; Davies, William R; West, Nick E J; Densem, Cameron G; Hoole, Stephen P

    2017-06-06

    We sought to determine whether right ventricular stunning could be detected after supply (during coronary balloon occlusion [BO]) and supply/demand ischemia (induced by rapid pacing [RP] during transcatheter aortic valve replacement) in humans. Ten subjects with single-vessel right coronary artery disease undergoing percutaneous coronary intervention with normal ventricular function were studied in the BO group. Ten subjects undergoing transfemoral transcatheter aortic valve replacement were studied in the RP group. In both, a conductance catheter was placed into the right ventricle, and pressure volume loops were recorded at baseline and for intervals over 15 minutes after a low-pressure BO for 1 minute or a cumulative duration of RP for up to 1 minute. Ischemia-induced diastolic dysfunction was seen 1 minute after RP (end-diastolic pressure [mm Hg]: 8.1±4.2 versus 12.1±4.1, P right coronary artery balloon occlusion both cause ischemic right ventricular dysfunction with stunning observed later during the procedure. This may have intraoperative implications in patients without right ventricular functional reserve. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  9. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.

    Science.gov (United States)

    Chhatriwalla, Adnan K; Allen, Keith B; Saxon, John T; Cohen, David J; Aggarwal, Sanjeev; Hart, Anthony J; Baron, Suzanne J; Dvir, Danny; Borkon, A Michael

    2017-07-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm 2 , P valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area. © 2017 American Heart Association, Inc.

  10. Aortic blood pressure measured via EIT: investigation of different measurement settings.

    Science.gov (United States)

    Braun, Fabian; Proença, Martin; Rapin, Michael; Lemay, Mathieu; Adler, Andy; Grychtol, Bartłomiej; Solà, Josep; Thiran, Jean-Philippe

    2015-06-01

    Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss-Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss-Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg.

  11. Aortic blood pressure measured via EIT: investigation of different measurement settings

    International Nuclear Information System (INIS)

    Braun, Fabian; Proença, Martin; Rapin, Michael; Lemay, Mathieu; Solà, Josep; Adler, Andy; Grychtol, Bartłomiej; Thiran, Jean-Philippe

    2015-01-01

    Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss–Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss–Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg. (paper)

  12. Clinical observation on treatment of Meibomian gland before IntraLase LASIK in patients with Meibomian gland dysfunction

    Directory of Open Access Journals (Sweden)

    He Huang

    2016-04-01

    Full Text Available AIM:To observe the changes of ocular surface inflammation and tear film state before and after the operation after preoperative targeted therapy for Meibomian gland in the patients scheduled for IntraLase-LASIK with Meibomian gland dysfunction(MGD. METHODS: Thirty-five patients(70 eyesscheduled for IntraLase-LASIK with different degrees of MGD from March to September 2014 were enrolled in this study. All patients were randomly divided into 2 groups, 17 patients(34 eyesin the observation group accepted preoperative targeted therapy for Meibomian gland; 18 patients(36 eyesin the control group did not give the treatment for Meibomian gland, the rest treatments were the same. The change of conjunctival congestion, photophobia, dry symptom score and tear break-up time(BUTwere observed at 1d and 1wk after IntraLase-LASIK. RESULTS: At 1d and 1wk postoperatively, the scores of conjunctival congestion, photophobia, dry symptom and BUT of the observation group were all lower than those of the control group, and the differences were significant(PCONCLUSION: For the patients scheduled for IntraLase-LASIK with MGD, preoperative targeted therapy for Meibomian gland can reduce the postoperative symptoms of ocular surface irritation, stabilize the tear film, improve the postoperative effect and improve the comfort of patients.

  13. Early Outcomes of Sutureless Aortic Valves

    Directory of Open Access Journals (Sweden)

    Muhammet Onur Hanedan

    2016-06-01

    Full Text Available Background: In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. Methods: Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA valves were used. Results: The mean age of the patients was 71.15±8.60 years. Forty-four patients (67.7% were female. The average preoperative left ventricular ejection fraction was 56.9±9.93. The CPB time was 96.51±41.27 minutes and the cross-clamping time was 60.85±27.08 minutes. The intubation time was 8.95±4.19 hours, and the intensive care unit and hospital stays were 2.89±1.42 days and 7.86±1.42 days, respectively. The mean quantity of drainage from chest tubes was 407.69±149.28 mL. The hospital mortality rate was 3.1%. A total of five patients (7.69% died during follow-up. The mean follow-up time was 687.24±24.76 days. The one-year survival rate was over 90%. Conclusion: In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time.

  14. Early Outcomes of Sutureless Aortic Valves.

    Science.gov (United States)

    Hanedan, Muhammet Onur; Mataracı, İlker; Yürük, Mehmet Ali; Özer, Tanıl; Sayar, Ufuk; Arslan, Ali Kemal; Ziyrek, Uğur; Yücel, Murat

    2016-06-01

    In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR) should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB) time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy) and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA) valves were used. The mean age of the patients was 71.15±8.60 years. Forty-four patients (67.7%) were female. The average preoperative left ventricular ejection fraction was 56.9±9.93. The CPB time was 96.51±41.27 minutes and the cross-clamping time was 60.85±27.08 minutes. The intubation time was 8.95±4.19 hours, and the intensive care unit and hospital stays were 2.89±1.42 days and 7.86±1.42 days, respectively. The mean quantity of drainage from chest tubes was 407.69±149.28 mL. The hospital mortality rate was 3.1%. A total of five patients (7.69%) died during follow-up. The mean follow-up time was 687.24±24.76 days. The one-year survival rate was over 90%. In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time.

  15. Acute Aortic Arch Perforation During Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis and a Gothic Aortic Arch.

    Science.gov (United States)

    Millan-Iturbe, Oscar; Sawaya, Fadi J; Bieliauskas, Gintautas; Chow, Danny H F; De Backer, Ole; Søndergaard, Lars

    2017-09-01

    Transcatheter aortic valve replacement (TAVR) has evolved from a novel technology to an established therapy for high/intermediate-risk patients with severe symptomatic aortic stenosis (AS). Although TAVR is used to treat bicuspid severe AS, the large randomized trials typically excluded bicuspid AS because of its unique anatomic features. This case report describes an acute aortic perforation during delivery of a transcatheter heart valve to treat a severe bicuspid AS with a "gothic aortic arch"; more careful evaluation of the preprocedural multislice computed tomographic scan would have unveiled a sharply angulated aortic arch. This life-threatening complication was successfully treated by thoracic endovascular aortic repair. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  16. Resuscitative endovascular balloon occlusion of the aorta: promise, practice, and progress?

    Science.gov (United States)

    Perkins, Zane B; Lendrum, Robbie A; Brohi, Karim

    2016-12-01

    Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a minimally invasive damage control procedure for life-threatening abdominal or pelvic haemorrhage. The purpose of this review is to summarize the current understanding and experience with REBOA, outline potential future applications of this technology, and highlight priority areas for further research. REBOA is a feasible method of achieving temporary aortic occlusion and can be performed rapidly, with a high degree of success, in the emergency setting (including at the scene of injury) by appropriately trained clinicians. The procedure supports central perfusion, controls noncompressible haemorrhage, and may improve survival in certain profoundly shocked patient groups; but is also associated with significant risks, including ischaemic tissue damage and procedural complications. Evolutions of this strategy are being explored, with promising proof-of-concept studies in the fields of partial aortic occlusion and the combination of REBOA with extracorporeal support. Noncompressible torso haemorrhage is the leading cause of preventable trauma deaths. The majority of these deaths occur soon after injury, often before any opportunity for definitive haemorrhage control. For a meaningful reduction in trauma mortality, novel methods of rapid haemorrhage control are required.

  17. Endovascular Treatment Strategies in Aortoiliac Occlusion

    International Nuclear Information System (INIS)

    Ozkan, Ugur; Oguzkurt, Levent; Tercan, Fahri; Gumus, Burcak

    2009-01-01

    The aim of this study was to report our experience in endovascular treatment of total aortoiliac occlusion. Five patients who underwent endovascular recanalization procedures including manual aspiration thrombectomy, balloon angioplasty, and stent placement for total aortoiliac occlusion in a 4-year period were reviewed retrospectively. The mean age of patients was 51 years (range, 43 to 58 years). All patients had abdominal aorta and bilateral common iliac artery occlusion with or without external iliac artery occlusion. All patients either had a contraindication to surgery or refused it. Initial technical success was obtained in four of five (80%) patients. Endovascular techniques were successful in four patients who had good distal runoff and short-segment aortoiliac occlusion, but failed in a patient who had the worst distal runoff and long-segment aortoiliac occlusion. We observed two major complications, one of which was bilateral rupture of the common iliac arteries treated with covered stent placement. Another patient had extension of intra-aortic thrombus into the iliac stent after primary stenting. This was successfully treated with manual aspiration thrombectomy. Aortic and iliac stents remained patent during the follow-up period (median, 18 months; range, 3 to 26 months) in four patients. Primary patency rates at 6, 12, and 24 months were all 80%. In conclusion, endovascular treatment can be an alternative for aortoiliac occlusion in selected patients. Short- to midterm follow-up so far is satisfactory. Removal of intra-aortic thrombus with manual aspiration thrombectomy before balloon angioplasty and/or stenting is possible and a good alternative to thrombolysis.

  18. Acute aortic dissection in patient with suspected pheochromocytoma

    Directory of Open Access Journals (Sweden)

    Lešanović Jelena

    2016-01-01

    Full Text Available Introduction: Aortic dissection is one of the most fatal vascular emergencies. Almost 40% of the patients do not reach hospital in time while more than quarter die in the first 24 hours after the dissection begins. Case Report: A 37-year old man was admitted to our hospital with severe anterior chest pain which had lasted for over a week. Suspected aortic dissection was rapidly confirmed using imaging modalities - MDCT chest scan and TTE, followed by an urgent surgical management - Bentall procedure. MDCT chest scan also discovered adrenal incidentaloma defined as malignant, pheochromocytoma like mass. Due to the critical state of the patient, there was not enough time for further endocrinologic testing. Discussion and conclusion: When treating patients with pheochromocytoma and acute aortic disection, it is crucial to obtain a stable hemodynamic state before the surgery, since they can trigger a severe hypertensive crisis due to high levels of cathecholamines induced chronic vasoconctriction. The most vulnerable periods are the induction of anesthesia and perioperative hemodynamic oscillations, so treating patients with short acting alpha- 1 adrenergic blocking agents preoperatively has proven to be helpful - Phentolamine. Both dissection of aorta and pheochromocytoma present challenges for anesthesiologists and early recognition of symptoms is essential in establishing the diagnosis and reducing the mortality rate.

  19. Dilatation and Dysfunction of the Neo-aortic Root and in 76 Patients After the Ross Procedure.

    Science.gov (United States)

    Zimmermann, Corina A; Weber, Roland; Greutmann, Matthias; Dave, Hitendu; Müller, Christoph; Prêtre, René; Seifert, Burkhardt; Buechel, Emanuela Valsangiacomo; Kretschmar, Oliver; Attenhofer Jost, Christine H

    2016-08-01

    Pulmonary autograft replacement (Ross procedure) is used as an alternative to prosthetic aortic valve replacement patients with aortic valve disease. There are limited data on incidence and risk factors for dilatation and dysfunction of the neo-aortic after the Ross procedure. Ross procedure was performed in 100 patients at our institution between 1993 and 2011. In 76 patients, complete follow-up data were available. Their median age at surgery was 16 (0.4-58) years (76 % males; 95 % with congenital aortic valve disease). Median follow-up duration was 5.2 years (0.3-16.0 years). We analyzed their clinical and echocardiographic follow-up to identify possible risk factors for neo-aortic root dilatation and dysfunction. Ross procedure included reduction plasty of the native ascending aorta in 25 % of patients. During follow-up, 21 patients (28 %) developed neo-aortic root dilatation, 38 patients (50 %) dilatation oft the native ascending aorta and 7 patients (9 %) at least moderate neo-aortic regurgitation. Univariate risk factors for neo-aortic root dilatation were preoperative aortic regurgitation (p = 0.04), concomitant reduction plasty of the ascending aorta (p = 0.009) and a longer duration of follow-up (p = 0.005). Younger age at surgery was associated with dilatation of the ascending aorta (p = 0.03). Reoperation on the neo-aortic root because of severe dilatation was necessary in 6 patients (8 %), where 2 patients had at least moderate neo-aortic root regurgitation. Neo-aortic root and aortic dilatation are common after the Ross procedure. This is often combined with neo-aortic valve dysfunction. Close follow-up of these patients is mandatory.

  20. Assessing the registration of CT-scan data to intraoperative x rays by fusing x rays and preoperative information

    Science.gov (United States)

    Gueziec, Andre P.

    1999-05-01

    This paper addresses a key issue of providing clinicians with visual feedback to validate a computer-generated registration of pre-operative and intra-operative data. With this feedback information, the clinician may decide to proceed with a computer-assisted intervention, revert to a manual intervention, or potentially provide information to the computer system to improve the registration. The paper focuses on total hip replacement (THR) surgery, but similar techniques could be applied to other types of interventions or therapy, including orthopedics, neurosurgery, and radiation therapy. Pre-operative CT data is used to plane the surgery (select an implant type, size and precise position), and is registered to intra-operative X-ray images, allowing to execute the plan: mill a cavity with the implant's shape. (Intra-operative X-ray images must be calibrated with respect to the surgical device executing the plan). One novel technique presented in this paper consists of simulating a post-operative X-ray image of the tissue of interest before doing the procedure, by projecting the registered implant onto an intra-operative X- ray image (corrected for distortion or not), providing clinicians with familiar and easy to interpret images. As an additional benefit, this method provides new means for comparing various strategies for registering pre-operative data to the physical space of the operating room.

  1. Aortic valve-sparing operation in Marfan syndrome: what do we know after a decade?

    Science.gov (United States)

    Kallenbach, Klaus; Baraki, Hassina; Khaladj, Nawid; Kamiya, Hiroyuki; Hagl, Christian; Haverich, Axel; Karck, Matthias

    2007-02-01

    We assessed the outcome in patients with Marfan syndrome operated on exclusively with the aortic valve-sparing reimplantation technique for aortic root aneurysms during more than a decade. Between July 1993 and April 2005, the aortic valve-sparing reimplantation technique (David I) was used in 325 patients. In 59 patients with clinical evidence of Marfan syndrome, procedures were done for aortic root aneurysm (n = 55) or aortic dissection type A (n = 4). Their mean age was 30 +/- 12 years (range, 9 to 62 years), and 37 (63%) were male. Additional procedures were arch replacement in 4 patients, coronary artery bypass grafting in 1, mitral valve surgery in 9, and closure of atrial septal defect in 3. Mean follow-up was 54 +/- 37 months (range, 0 to 139 months). No patient died during the first 30 days postoperatively. Mean bypass time was 163 +/- 34 minutes (range, 99 to 248 minutes), and mean aortic cross clamp time was 126 +/- 28 minutes (range, 78 to 202 minutes). Four patients (6.8%) required rethoracotomy for postoperative bleeding. Five late deaths (8.5%) occurred during follow-up. Reoperation of the reconstructed valve was required in 7 patients. Freedom from reoperation was 88% +/- 5% at 5 years and 80% +/- 9% at 10 years. Mean grade of aortic insufficiency was 1.81 preoperatively compared with 0.20 early postoperatively (p valve should encourage use of this technique in patients with Marfan syndrome.

  2. Aortopulmonary Fistula Presenting without an Endoleak after Thoracic Endovascular Aortic Repair

    Directory of Open Access Journals (Sweden)

    Giacomo Sica

    2017-08-01

    Full Text Available Herein, we report the case of a 60-year-old man, a smoker with a history of arterial hypertension and diabetes mellitus. After computed tomography (CT for an episode of hemoptysis, the patient underwent elective thoracic endovascular aortic repair (TEVAR because of a degenerative aneurysm of the descending thoracic aorta. The area of perianeurysmal pulmonary atelectasis reported on the CT scan was not considered. Three months later, he developed an aortopulmonary fistula without endoleaks. Although TEVAR is a relatively safe procedure, no detail should be overlooked in the preoperative evaluation in order to avoid life-threatening complications. Further, the effectiveness and modality of prolonged antibiotic prophylaxis and/or preoperative respiratory physiotherapy should be assessed in such cases.

  3. The impact of aortic manipulation on neurologic outcomes after coronary artery bypass surgery: a risk-adjusted study.

    Science.gov (United States)

    Kapetanakis, Emmanouil I; Stamou, Sotiris C; Dullum, Mercedes K C; Hill, Peter C; Haile, Elizabeth; Boyce, Steven W; Bafi, Ammar S; Petro, Kathleen R; Corso, Paul J

    2004-11-01

    Cerebral embolization of atherosclerotic plaque debris caused by aortic manipulation during conventional coronary artery bypass grafting (CABG) is a major mechanism of postoperative cerebrovascular accidents (CVA). Off-pump CABG (OPCABG) reduces stroke rates by minimizing aortic manipulation. Consequently, the effect of different levels of aortic manipulation on neurologic outcomes after CABG surgery was examined. From January 1998 to June 2002, 7,272 patients underwent isolated CABG surgery through three levels of aortic manipulation: full plus tangential (side-biting) aortic clamp application (on-pump surgery; n = 4,269), only tangential aortic clamp application (OPCABG surgery; n = 2,527) or an "aortic no-touch" technique (OPCABG surgery; n = 476). A risk-adjusted logistic regression analysis was performed to establish the likelihood of postoperative stroke with each technique. Preoperative risk factors for stroke from the literature, and those found significant in a univariable model were used. A significant association for postoperative stroke correspondingly increasing with the extent of aortic manipulation was demonstrated by the univariable analysis (CVA incidence respectively increasing from 0.8% to 1.6% to a maximum of 2.2%, p < 0.01). In the logistic regression model, patients who had a full and a tangential aortic clamp applied were 1.8 times more likely to have a stroke versus those without any aortic manipulation (95% confidence interval: 1.15 to 2.74, p < 0.01) and 1.7 times more likely to develop a postoperative stroke than those with only a tangential aortic clamp applied (95% confidence interval: 1.11 to 2.48, p < 0.01). Aortic manipulation during CABG is a contributing mechanism for postoperative stroke. The incidence of postoperative stroke increases with increased levels of aortic manipulation.

  4. Single aortic clamping in coronary artery bypass surgery reduces cerebral embolism and improves neurocognitive outcomes.

    Science.gov (United States)

    Gasparovic, Hrvoje; Borojevic, Marko; Malojcic, Branko; Gasparovic, Kristina; Biocina, Bojan

    2013-10-01

    Aortic manipulation releases embolic material, thereby enhancing the probability of adverse neurologic outcomes following coronary artery bypass grafting (CABG). We prospectively evaluated 59 patients undergoing CABG. Patients in the single (SC, n = 37) and multiple clamp (MC, n = 22) groups were comparable in relation to age and operative risk (p > 0.05). Neurocognitive evaluation consisted of the Auditory Verbal Learning Test (AVLT), Color Trails Test A, the Grooved Pegboard test and the Mini-Mental State Examination. Data acquisition was performed preoperatively, early postoperatively and at the 4-month follow-up. Intraoperative transcranial Doppler (TCD) monitoring was used to quantify the embolic load in relation to different aortic clamping strategies. Preoperative neurocognitive results were similar between the groups (p > 0.05). The incidence of postoperative delirium was greater in the MC group but this failed to reach statistical significance (23% vs 8%, p = 0.14). SC patients had fewer embolization signals (270 ± 181 vs 465 ± 160, p cognitive depression was greater in the MC group (p cognition deficits and superior late restoration of function.

  5. Valve-sparing aortic root replacement in children: intermediate-term results.

    Science.gov (United States)

    Patel, Nishant D; Arnaoutakis, George J; George, Timothy J; Allen, Jeremiah G; Alejo, Diane E; Dietz, Harry C; Cameron, Duke E; Vricella, Luca A

    2011-03-01

    Valve-sparing root replacement (VSRR) is an attractive option for aortic aneurysm in children with low-operative risk, but mid- and late-term results are not yet known. Between 1997 and 2009, 56 children (mean age 11.5 years) underwent VSRR at our institution. Twenty-six (46.4%) had Marfan syndrome and 24 (42.8%) had Loeys-Dietz syndrome. Mean preoperative max sinus diameter was 4.2±0.8 cm (Z-score 7.7±2.9). Five (8.9%) had >2+ aortic insufficiency (AI). Two (3.6%) underwent David I reimplantation with a straight-tube, 12 (21.4%) had a Yacoub remodeling procedure, and 42 (75.0%) had reimplantation using a Valsalva-graft. There were one (1.8%) operative and three (5.4%) late deaths. One patient required reoperation for bleeding and one required late repair of a distal pseudoaneurysm. Mean follow-up was 5.2 years (range 0-12 years). No patients suffered thromboembolic events or had endocarditis. Of the 12 remodeling patients, four (33.3%) developed >2+ AI and required aortic valve repair or replacement. No patient developed >2+ AI after reimplantation. VSRR in children is a safe alternative to aortic root replacement with mechanical or biological prostheses. In this particular group of patients with connective tissue disorders and proclivity toward annular dilation and late AI, reimplantation is superior to remodeling.

  6. Clefting in pumpkin balloons

    Science.gov (United States)

    Baginski, F.; Schur, W.

    NASA's effort to develop a large payload, high altitude, long duration balloon, the Ultra Long Duration Balloon, focuses on a pumpkin shape super-pressure design. It has been observed that a pumpkin balloon may be unable to pressurize into the desired cyclically symmetric equilibrium configuration, settling into a distorted, undesired stable state instead. Hoop stress considerations in the pumpkin design leads to choosing the lowest possible bulge radius, while robust deployment is favored by a large bulge radius. Some qualitative understanding of design aspects on undesired equilibria in pumpkin balloons has been obtained via small-scale balloon testing. Poorly deploying balloons have clefts, but most gores away from the cleft deploy uniformly. In this paper, we present models for pumpkin balloons with clefts. Long term success of the pumpkin balloon for NASA requires a thorough understanding of the phenomenon of multiple stable equilibria and means for quantitative assessment of measures that prevent their occurrence. This paper attempts to determine numerical thresholds of design parameters that distinguish between properly deploying designs and improperly deploying designs by analytically investigating designs in the vicinity of criticality. Design elements which may trigger the onset undesired equilibria and remedial measures that ensure deployment are discussed.

  7. Aortic Root Replacement for Children With Loeys-Dietz Syndrome.

    Science.gov (United States)

    Patel, Nishant D; Alejo, Diane; Crawford, Todd; Hibino, Narutoshi; Dietz, Harry C; Cameron, Duke E; Vricella, Luca A

    2017-05-01

    Loeys-Dietz syndrome (LDS) is an aggressive aortopathy with a proclivity for aortic aneurysm rupture and dissection at smaller diameters than other connective tissue disorders. We reviewed our surgical experience of children with LDS to validate our guidelines for prophylactic aortic root replacement (ARR). We reviewed all children (younger than 18 years) with a diagnosis of LDS who underwent ARR at our institution. The primary endpoint was mortality, and secondary endpoints included complications and the need for further interventions. Thirty-four children with LDS underwent ARR. Mean age at operation was 10 years, and 15 (44%) were female. Mean preoperative root diameter was 4 cm. Three children (9%) had composite ARR with a mechanical prosthesis, and 31 (91%) underwent valve-sparing ARR. Concomitant procedures included arch replacement in 2 (6%), aortic valve repair in 1 (3%), and patent foramen ovale closure in 16 (47%). There was no operative mortality. Two children (6%) required late replacement of the ascending aorta, 5 (15%) required arch replacement, 1 (3%) required mitral valve replacement, and 2 (6%) had coronary button aneurysms/pseudoaneurysms requiring repair. Three children required redo valve-sparing ARR after a Florida sleeve procedure, and 2 had progressive aortic insufficiency requiring aortic valve replacement after a valve-sparing procedure. There were 2 late deaths (6%). These data confirm the aggressive aortopathy of LDS. Valve-sparing ARR should be performed when feasible to avoid the risks of prostheses. Serial imaging of the arterial tree is critical, given the rate of subsequent intervention. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Carotid and coronary disease management prior to open and endovascular aortic surgery. What are the current guidelines?

    Science.gov (United States)

    Thompson, J P

    2014-04-01

    Several bodies produce broadly concurring and updated guidelines for the evaluation and treatment of cardiovascular disease in both surgical and non-surgical patients. Recent developments include revised recommendations on preoperative stress testing, referral for possible coronary revascularization and medical management. It is recognized that non-invasive cardiac tests are relatively poor at predicting perioperative risk, and "prophylactic" coronary revascularization has a limited role. The planned aortic intervention (open or endovascular repair) also influences preoperative management. Patients presenting for elective abdominal aortic aneurysm (AAA) repair should only be referred for cardiological testing if they have active symptoms of coronary artery disease (CAD), known CAD and poor functional exercise capacity, or multiple risk factors for CAD. Coronary revascularization before AAA surgery should be limited to patients with established indications, so cardiac stress testing should only be performed if it would change management i.e. the patient is a candidate for and would benefit from coronary revascularization. When endovascular aortic repair is planned, it is reasonable to proceed to surgery without further cardiac stress testing or evaluation unless otherwise indicated. All non-emergency patients require medical optimization, but perioperative beta blockade benefits only certain patients. Some of the data informing recent guidelines have been questioned and some guidelines are being revised. Current guidelines do not specifically address the management of patients with known or suspected carotid artery disease who may require aortic surgery. For these patients, an individualized approach is required. This review considers recent guidelines. Algorithms for investigation and management based on their recommendations are included.

  9. Blood flow dynamic improvement with aneurysm repair detected by a patient-specific model of multiple aortic aneurysms.

    Science.gov (United States)

    Sughimoto, Koichi; Takahara, Yoshiharu; Mogi, Kenji; Yamazaki, Kenji; Tsubota, Ken'ichi; Liang, Fuyou; Liu, Hao

    2014-05-01

    Aortic aneurysms may cause the turbulence of blood flow and result in the energy loss of the blood flow, while grafting of the dilated aorta may ameliorate these hemodynamic disturbances, contributing to the alleviation of the energy efficiency of blood flow delivery. However, evaluating of the energy efficiency of blood flow in an aortic aneurysm has been technically difficult to estimate and not comprehensively understood yet. We devised a multiscale computational biomechanical model, introducing novel flow indices, to investigate a single male patient with multiple aortic aneurysms. Preoperative levels of wall shear stress and oscillatory shear index (OSI) were elevated but declined after staged grafting procedures: OSI decreased from 0.280 to 0.257 (first operation) and 0.221 (second operation). Graftings may strategically counter the loss of efficient blood delivery to improve hemodynamics of the aorta. The energy efficiency of blood flow also improved postoperatively. Novel indices of pulsatile pressure index (PPI) and pulsatile energy loss index (PELI) were evaluated to characterize and quantify energy loss of pulsatile blood flow. Mean PPI decreased from 0.445 to 0.423 (first operation) and 0.359 (second operation), respectively; while the preoperative PELI of 0.986 dropped to 0.820 and 0.831. Graftings contributed not only to ameliorate wall shear stress or oscillatory shear index but also to improve efficient blood flow. This patient-specific modeling will help in analyzing the mechanism of aortic aneurysm formation and may play an important role in quantifying the energy efficiency or loss in blood delivery.

  10. Thoracoabdominal aortic aneurysm repair in patients with marfan syndrome.

    Science.gov (United States)

    Mommertz, G; Sigala, F; Langer, S; Koeppel, T A; Mess, W H; Schurink, G W H; Jacobs, M J

    2008-02-01

    We assessed the surgical outcome of descending thoracic aortic aneurysm repair (DTAA) and thoracoabdominal aortic aneurym (TAAA) repair in patients with Marfan syndrome. During a six year period, 206 patients underwent DTAA and TAAA repair. In 22 patients, Marfan syndrome was confirmed. The median age was 40 years with a range between 18 and 57 years. The extend of the aneurysms included 6 DTAA (1 with total arch, 2 with distal hemi-arch), 11 type II TAAA (2 with total arch, 3 with distal hemi-arch), 4 type III and one type IV TAAA. All patients suffered from previous type A (n=6) or type B (n=16) aortic dissection and 15 already underwent aortic procedures like Bentall (n=7) and ascending aortic replacement (n=8). All patients were operated on according to the standard protocol with cerebrospinal fluid drainage, distal aortic and selective organ perfusion and monitoring motor evoked potentials. In patients undergoing simultaneous arch replacement (via left thoracotomy), transcranial Doppler and EEG assessed cerebral physiology during antegrade brain perfusion. In four patients circulatory arrest under moderate hypothermia was required. In-hospital mortality did not occur. Major postoperative complications like paraplegia, renal failure, stroke and myocardial infarction were not encountered. Mean pre-operative creatinine level was 125mmol/L, which peaked to a mean maximal level of 130 and returned to 92mmol/L at discharge. Median intubation time was 1.5 days (range 0.33-30 days). Other complications included bleeding requiring surgical intervention (n=1), arrhythmia (n=2), pneumonia (n=2) and respiratory distress syndrome (n=1). At a median follow-up of 38 months all patients were alive. Using CT surveillance, new or false aneurysms were not detected, except in one patient who developed a visceral patch aneurysm six years after open type II repair. Surgical repair of descending and thoracoabdominal aortic aneurysms provides excellent short- and mid-term results in

  11. Aortic anatomic severity grade correlates with resource utilization.

    Science.gov (United States)

    Rasheed, Khurram; Cullen, John P; Seaman, Matthew J; Messing, Susan; Ellis, Jennifer L; Glocker, Roan J; Doyle, Adam J; Stoner, Michael C

    2016-03-01

    Potential cost effectiveness of endovascular aneurysm repair (EVAR) compared with open aortic repair (OAR) is offset by the use of intraoperative adjuncts (components) or late reinterventions. Anatomic severity grade (ASG) can be used preoperatively to assess abdominal aortic aneurysms, and provide a quantitative measure of anatomic complexity. The hypothesis of this study is that ASG is directly related to the use of intraoperative adjuncts and cost of aortic repair. Patients who undergo elective OAR and EVAR for abdominal aortic aneurysms were identified over a consecutive 3-year period. ASG scores were calculated manually using three-dimensional reconstruction software by two blinded reviewers. Statistical analysis of cost data was performed using a log transformation. Regression analyses, with a continuous or dichotomous outcome, used a generalized estimating equations approach with the sandwich estimator, being robust with respect to deviations from model assumptions. One hundred forty patients were identified for analysis, n = 33 OAR and n = 107 EVAR. The mean total cost (± standard deviation) for OAR was per thousand (k) $38.3 ± 49.3, length of stay (LOS) 13.5 ± 14.2 days, ASG score 18.13 ± 3.78; for EVAR, mean total cost was k $24.7 ± 13.0 (P = .016), LOS 3.0 ± 4.4 days (P = .012), ASG score 15.9 ± 4.13 (P = .010). In patients who underwent EVAR, 25.2% required intraoperative adjuncts, and analysis of this group revealed a mean total cost of k $31.5 ± 15.9, ASG score 18.48 ± 3.72, and LOS 3.9 ± 4.5, which were significantly greater compared with cases without adjunctive procedures. An ASG score of ≥15 correlated with an increased propensity for requirement of intraoperative adjuncts; odds ratio, 5.75 (95% confidence interval, 1.82-18.19). ASG >15 was also associated with chronic kidney disease, end stage renal disease, hypertension, female sex, increased cost, and use of adjunctive procedures. Complex aneurysm anatomy correlates with increased

  12. [Valvular heart disease: preoperative assessment and postoperative care].

    Science.gov (United States)

    Nägele, Reto; Kaufmann, Beat A

    2013-10-30

    Patients with valvular heart disease or with a prosthetic heart valve replacement are seen with increasing frequency in clinical practice. The medical care and evaluation of patients with valvular heart disease before valve surgery, but also the post-operative treatment is complex and managed by general practitioners, cardiologists and cardiac surgeons. In this mini-review we will first discuss the preoperative assessment of the two most common valvulopathies, aortic stenosis and mitral regurgitation. Then we will discuss the post-operative care, which includes the management of anticoagulation, serial follow up and as well as the diagnostic assessment of complications such as thromboembolism, hemolysis, endocarditis and valve dysfunction.

  13. Mitral valve disease in patients with Marfan syndrome undergoing aortic root replacement.

    Science.gov (United States)

    Kunkala, Meghana R; Schaff, Hartzell V; Li, Zhuo; Volguina, Irina; Dietz, Harry C; LeMaire, Scott A; Coselli, Joseph S; Connolly, Heidi

    2013-09-10

    Cardiac manifestations of Marfan syndrome include aortic root dilation and mitral valve prolapse (MVP). Only scant data exist describing MVP in patients with Marfan syndrome undergoing aortic root replacement. We retrospectively analyzed data from 166 MFS patients with MVP who were enrolled in a prospective multicenter registry of patients who underwent aortic root aneurysm repair. Of these 166 patients, 9% had mitral regurgitation (MR) grade >2, and 10% had MR grade 2. The severity of MVP and MR was evaluated by echocardiography preoperatively and ≤ 3 years postoperatively. Forty-one patients (25%) underwent composite graft aortic valve replacement, and 125 patients (75%) underwent aortic valve-sparing procedures; both groups had similar prevalences of MR grade >2 (P=0.7). Thirty-three patients (20%) underwent concomitant mitral valve (MV) intervention (repair, n=29; replacement, n=4), including all 15 patients with MR grade >2. Only 1 patient required MV reintervention during follow-up (mean clinical follow-up, 31 ± 10 months). Echocardiography performed 21 ± 13 months postoperatively revealed MR >2 in only 3 patients (2%). One early death and 2 late deaths occurred. Although the majority of patients with Marfan syndrome who undergo elective aortic root replacement have MVP, only 20% have concomitant MV procedures. These concomitant procedures do not seem to increase operative risk. In patients with MR grade ≤ 2 who do not undergo a concomitant MV procedure, the short-term incidence of progressive MR is low; however, more follow-up is needed to determine whether patients with MVP and MR grade ≤ 2 would benefit from prophylactic MV intervention.

  14. Balloon sinuplasty

    OpenAIRE

    Ahmad, Zahoor

    2010-01-01

    Balloon sinuplasty is a technique in endoscopic sinus surgery that involves minimally invasive procedures to dilate the obstructed or stenosed anatomical sinus pathways. Procedure is derived from the well-recognized techinique of angioplasty. This article highlights the procedural methods with review of literature and my personal experience in balloon sinupalsty.

  15. Clinical application of preoperative TAE in the nasopharyngeal angiofibromas

    International Nuclear Information System (INIS)

    Liu Yu'e; Zhang Jingxian; Tang Wenheng; Yan Zhiping

    2006-01-01

    Objective: To evaluate the clinical value of the preoperative intra-arterial embolization of the nasopharyngeal angiofibromas. Methods: The treatment group of 7 male patients with the nasopharyngeal angiofibromas were undergone angiographic evaluation and embolization of tumor-feeding vessels before surgery. All patients were embolized with gelfoam particles and PVA. The control group of 7 patients received surgical treatment without preoperative embolization. The authors compared the volumes of intraoperative bleeding and the blood transfusions during operations between the two groups. Results: All patients achieved symptomatic remission, with no complications. Comparing with the control group, the amount of intraoperative bleeding and the blood transfusions during operations were much less in the treatment group submitted to endovascular embolization. Marked edema in the peripheral region of tumor of the treatment group made the tumor easy to be dissociated. Conclusion: The intraoperative bleeding can be reduced significantly by preoperative embolization of supplying arteries to the nasopharyngeal angiofibromas, therefore it should be used routinely as an adjunct to surgery. (authors)

  16. National Report on the NASA Sounding Rocket and Balloon Programs

    Science.gov (United States)

    Eberspeaker, Philip; Fairbrother, Debora

    2013-01-01

    The U. S. National Aeronautics and Space Administration (NASA) Sounding Rockets and Balloon Programs conduct a total of 30 to 40 missions per year in support of the NASA scientific community and other users. The NASA Sounding Rockets Program supports the science community by integrating their experiments into the sounding rocket payloads, and providing both the rocket vehicle and launch operations services. Activities since 2011 have included two flights from Andoya Rocket Range, more than eight flights from White Sands Missile Range, approximately sixteen flights from Wallops Flight Facility, two flights from Poker Flat Research Range, and four flights from Kwajalein Atoll. Other activities included the final developmental flight of the Terrier-Improved Malemute launch vehicle, a test flight of the Talos-Terrier-Oriole launch vehicle, and a host of smaller activities to improve program support capabilities. Several operational missions have utilized the new Terrier-Malemute vehicle. The NASA Sounding Rockets Program is currently engaged in the development of a new sustainer motor known as the Peregrine. The Peregrine development effort will involve one static firing and three flight tests with a target completion data of August 2014. The NASA Balloon Program supported numerous scientific and developmental missions since its last report. The program conducted flights from the U.S., Sweden, Australia, and Antarctica utilizing standard and experimental vehicles. Of particular note are the successful test flights of the Wallops Arc Second Pointer (WASP), the successful demonstration of a medium-size Super Pressure Balloon (SPB), and most recently, three simultaneous missions aloft over Antarctica. NASA continues its successful incremental design qualification program and will support a science mission aboard WASP in late 2013 and a science mission aboard the SPB in early 2015. NASA has also embarked on an intra-agency collaboration to launch a rocket from a balloon to

  17. Balloon Occlusion of the Contralateral Iliac Artery to Assist Recanalization of the Ipsilateral Iliac Artery in Total Aortoiliac Occlusion: A Technical Note

    Directory of Open Access Journals (Sweden)

    Abdel Aziz A. Jaffan

    2013-01-01

    Full Text Available Endovascular recanalization of chronic total aortoiliac occlusion is technically challenging. Inability to reenter the true aortic lumen, following retrograde iliac recanalization, is one of the most common causes of failure. We describe a case of a total aortoiliac occlusion where balloon occlusion of the right common iliac artery, following its recanalization from a brachial approach, was used to facilitate antegrade recanalization of the occluded contralateral left common iliac artery.

  18. Left ventricular outflow tract to left atrial communication secondary to rupture of mitral-aortic intervalvular fibrosa in infective endocarditis: diagnosis by transesophageal echocardiography and color flow imaging.

    Science.gov (United States)

    Bansal, R C; Graham, B M; Jutzy, K R; Shakudo, M; Shah, P M

    1990-02-01

    Infection of the mitral-aortic intervalvular fibrosa occurs most commonly in association with infective endocarditis of the aortic valve. Infection of the aortic valve results in a regurgitant jet that presumably strikes this subaortic interannular zone of fibrous tissue and produces a secondary site of infection. Infection of this interannular zone then leads to the formation of subaortic abscess or pseudoaneurysm of the left ventricular outflow tract. This infected zone of mitral-aortic intervalvular fibrosa or subaortic aneurysm can subsequently rupture into the left atrium with systolic ejection of blood from the left ventricular outflow tract to the left atrium. This report describes the echocardiographic findings in three patients with pathologically proved left ventricular outflow tract to left atrial communication. Precise preoperative diagnosis is important, and this lesion should be differentiated from ruptured aneurysm of the sinus of Valsalva and perforation of the anterior mitral leaflet. Transthoracic echocardiography using color flow imaging and conventional Doppler techniques may show an eccentric mitral regurgitation type of signal in the left atrium originating from the region of the left ventricular outflow tract. However, transesophageal echocardiography provides an accurate preoperative diagnosis and should be used intraoperatively during repair of such lesions.

  19. Pre-operative risk scores for the prediction of outcome in elderly people who require emergency surgery

    Directory of Open Access Journals (Sweden)

    Bates Tom

    2007-06-01

    Full Text Available Abstract Background The decision on whether to operate on a sick elderly person with an intra-abdominal emergency is one of the most difficult in general surgery. A predictive risk-score would be of great value in this situation. Methods A Medline search was performed to identify those predictive risk-scores relevant to sick elderly patients in whom emergency surgery might be life-saving. Results Many of the risk scores for surgical patients include the operative findings or require tests which are not available in the acute situation. Most of the relevant studies include younger patients and elective surgery. The Glasgow Aneurysm Score and Hardman Index are specific to ruptured aortic aneurysm while the Boey Score and the Hacetteppe Score are specific to perforated peptic ulcer. The Reiss Index and Fitness Score can be used pre-operatively if the elements of the score can be completed in time. The ASA score, which includes a significant element of subjective clinical judgement, can be augmented with factors such as age and urgency of surgery but no test has a negative predictive value sufficient to recommend against surgical intervention without clinical input. Conclusion Risk scores may be helpful in sick elderly patients needing emergency abdominal surgery but an experienced clinical opinion is still essential.

  20. Optimal timing of aortic valve replacement in elderly patients with severe aortic stenosis.

    Science.gov (United States)

    Marumoto, Akira; Nakamura, Yoshinobu; Kishimoto, Yuichiro; Saiki, Munehiro; Nishimura, Motonobu

    2014-01-01

    The elderly population with severe aortic stenosis (AS) requiring aortic valve replacement (AVR) is increasing. The optimal timing of AVR in these patients has been under discussion. We retrospectively reviewed the data from severe AS patients (n = 84) who underwent AVR with/without concomitant procedures from 2005 to 2010. The symptom status, preoperative data, operative outcome, late survival and freedom from cardiac events were compared between elderly patients (age ≥80 years [n = 31]) and younger patients (age <80 years [n = 53]). The operative mortality in elderly patients (3.2 %) and younger patients (3.8 %) was comparable. The symptoms in elderly patients were more severe and hospitalized heart failure (HF) was more frequently noted as the primary symptom (p = 0.017). Patients with and without hospitalized HF differed significantly in late survival and freedom from cardiac events (p = 0.001), but advanced age had no significant effect. The results of a Cox proportional hazards analysis revealed that hospitalized HF was a significant predictor for cardiac events after AVR, irrespective of age (hazard ratio 6.93, 95 % confidence interval 1.83-26.26, p < 0.004). In elderly patients with severe AS, surgery should be recommended even in the presence of minimal symptoms and should be performed before the onset of life-threatening HF.

  1. Aortic insufficiency

    Science.gov (United States)

    ... page, please enable JavaScript. Aortic insufficiency is a heart valve disease in which the aortic valve does not close ... aortic insufficiency Images Aortic insufficiency References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman-Cecil ...

  2. Status of the NASA Balloon Program

    Science.gov (United States)

    Needleman, H. C.; Nock, R. S.; Bawcom, D. W.

    1993-02-01

    In the early 1980's the U.S. National Aeronautics and Space Administration (NASA) Balloon Program was faced with a problem of catastrophic balloon failures. In 1986 a balloon recovery program was initiated. This program included qualification of new balloon films, and investigations into materials, processing, structures and performance of balloons. This recovery program has been very successful. To date, more than 100 balloons manufactured of newly developed films have been flown with unprecedented success. There has been much progress made across the spectrum of balloon related disciplines. A new design philosophy has been developed and is being used for all NASA balloons. An updated balloon reliability and quality assurance program is in effect. The long duration balloon development project has been initiated with the first flight test having been conducted in December 1989 from Antarctica. A comprehensive research and development (R&D) effort has been initiated and is progressing well. The progress, status and future plans for these and other aspects of the NASA program, along with a description of the comprehensive balloon R&D activity, will be presented.

  3. PREOPERATIVE ENDOSCOPIC MARKING OF UNPALPABLE COLONIC TUMORS

    Directory of Open Access Journals (Sweden)

    A. L. Goncharov

    2013-01-01

    Full Text Available The identification of small colon lesions is one of the major problems in laparoscopic colonic resection.Research objective: to develop a technique of visualization of small tumors of a colon by preoperative endoscopic marking of a tumor.Materials and methods. In one day prior to operation to the patient after bowel preparation the colonoscopy is carried out. In the planned point near tumor on antimesentery edge the submucous infiltration of marking solution (Micky Sharpz blue tattoo pigment, UK is made. The volume of entered solution of 1–3 ml. In only 5 months of use of a technique preoperative marking to 14 patients with small (the size of 1–3 cm malignant tumors of the left colon is performed.Results. The tattoo mark was well visualized by during operation at 13 of 14 patients. In all cases we recorded no complications. Time of operation with preoperative marking averaged 108 min, that is significantly less in comparison with average time of operation with an intra-operative colonoscopy – 155 min (р < 0.001.Conclusions. The first experience of preoperative endoscopic marking of non palpable small tumors of a colon is encouraging. Performance of a technique wasn't accompanied by complications and allowed to reduce significantly time of operation and to simplify conditions of performance of operation.

  4. Direct percutaneous transaortic approach for treatment of aortic pseudoaneurysms.

    Science.gov (United States)

    Pirelli, Luigi; Kliger, Chad; Fontana, Gregory P; Ruiz, Carlos E

    2015-05-01

    Aortic pseudoaneurysms (APAs) can develop months or years after aortic and cardiac surgery. If not treated appropriately, APAs can lead to fatal complications and ultimately death. We describe a case of a 61-year old patient with a diagnosed large pseudoaneurysm 5 years after his aortic valve surgery, who was treated with a novel transcatheter direct transaortic approach. The patient had dilated cardiomyopathy with an APA adjacent to the lower sternal plate. An Amplatzer septal occlusion device followed by coils was delivered transcutaneously through the APA to close its neck and fill the false aneurysm, respectively. Triple fusion multimodality imaging was used to guide the placement of the occlusion devices. The merging of computed tomography (CT) and echocardiography with real-time fluoroscopy was fundamental in procedural planning and guidance. Post-procedural transoesophageal echocardiogram (TOE) and CT angiography showed complete exclusion of the APA. A direct transaortic approach is a valid option for closure of an APA if the surgical risk is prohibitive, and the use of triple fusion technology is an essential tool in the hands of interventionalists and surgeons for preoperative planning and conduction of these procedures. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  5. Volumetric analysis demonstrates that true and false lumen remodeling persists for 12 months after thoracic endovascular aortic repair

    Directory of Open Access Journals (Sweden)

    Ga-Young Suh, PhD

    2016-09-01

    Full Text Available A 62-year-old man underwent an elephant trunk procedure followed by thoracic endovascular aortic repair (TEVAR. Computed tomography angiography-based models were built to quantify volume of the whole aorta and true and false lumens preoperatively, before TEVAR, after TEVAR, and at follow-up at 3, 6, and 12 months. With TEVAR, descending aortic true lumen volume increased by 54%, then increased additionally by 60% during 12 months. The descending aortic false lumen volume regressed continuously for 12 months following TEVAR, with the most rapid rate from 6 to 12 months at 16 cm3/month. TEVAR immediately increased true lumen volume and continued to remodel the true and false lumens throughout the following 12 months.

  6. Investigation of hot air balloon fatalities.

    Science.gov (United States)

    McConnell, T S; Smialek, J E; Capron, R G

    1985-04-01

    The rising popularity of the sport of hot air ballooning has been accompanied by several recent incidents, both in this country and other parts of the world, where mechanical defects and the improper operation of balloons have resulted in several fatalities. A study was conducted to identify the location and frequency of hot air ballooning accidents. Furthermore, the study attempted to identify those accidents that were the result of improper handling on the part of the balloon operators and those that were related to specific defects in the construction of the balloon. This paper presents a background of the sport of hot air ballooning, together with an analysis of the construction of a typical hot air balloon, pointing out the specific areas where defects may occur that could result in a potential fatal balloon crash. Specific attention is given to the two recent balloon crashes that occurred in Albuquerque, N.M., hot air balloon capital of the world, and that resulted in multiple fatalities.

  7. Central Sleep Apnea in Patients due to Severe Aortic Stenosis

    Directory of Open Access Journals (Sweden)

    Christian Prinz

    2010-01-01

    Full Text Available History. We report about the course of central sleep apnea (CSA in 3 patients (70.3±15.2 years with severe aortic stenosis (AS (AVA≤1.0 cm2, NYHA 2.7±1.4. Investigations. Every patient received echocardiography, left/right-heart catheterization, and cardiorespiratory polygraphy before and 6 months after surgical aortic valve replacement (without right-heart catheterization during follow up. Course. Preoperatively all patients demonstrated reduced systolic left ventricular function (EF <55%. They had elevated pulmoraryarterialy pressures and severe CSA. After valve replacement left ventricular function and exercise capacity improved, as well as the severity of CSA. Conclusion. Patients with severe AS can develop CSA, which seems to improve after surgery. Patients with severe AS should be screened for CSA, because CSA might be an additional risk factor and hint that myocardial adaptation is exhausting.

  8. Early results of valve-sparing ascending aortic replacement in type A aortic dissection and aortic insufficiency

    Directory of Open Access Journals (Sweden)

    М. Л. Гордеев

    2016-08-01

    Full Text Available Aim: The study was designed to investigate predictors of effective valve-sparing ascending aortic replacement in patients with Stanford type A aortic dissection combined with aortic insufficiency and to analyze efficacy and safety of this kind of surgery.Methods: From January 2010 to December 2015, 49 patients with Stanford type A aortic dissection combined with aortic insufficiency underwent ascending aortic replacement. All patients were divided into 3 groups: valve-sparing procedures (group 1, n = 11, combined aortic valve and supracoronary ascending aortic replacement (group 2, n = 12, and Bentall procedure (group 3, n = 26. We assessed the initial status of patients, incidence of complications and efficacy of valve-sparing ascending aortic replacement.Results: The hospital mortality rate was 8.2% (4/49 patients. The amount of surgical correction correlated with the initial diameter of the aorta at the level of the sinuses of Valsalva. During the hospital period, none of patients from group 1 developed aortic insufficiency exceeding Grade 2 and the vast majority of patients had trivial aortic regurgitation. The parameters of cardiopulmonary bypass, cross-clamp time and circulatory arrest time did not correlate with the initial size of the ascending aorta and aortic valve blood flow impairment, neither did they influence significantly the incidence and severity of neurological complications. The baseline size of the ascending aorta and degree of aortic regurgitation did not impact the course of the early hospital period.Conclusions: Supracoronary ascending aortic replacement combined with aortic valve repair in ascending aortic dissection and aortic regurgitation is effective and safe. The initial size of the ascending aorta and aortic arch do not influence immediate results. The diameter of the aorta at the level of the sinuses of Valsalva and the condition of aortic valve leaflets could be considered as the limiting factors. Further long

  9. Cleft formation in pumpkin balloons

    Science.gov (United States)

    Baginski, Frank E.; Brakke, Kenneth A.; Schur, Willi W.

    NASA’s development of a large payload, high altitude, long duration balloon, the Ultra Long Duration Balloon, centers on a pumpkin shape super-pressure design. Under certain circumstances, it has been observed that a pumpkin balloon may be unable to pressurize into the desired cyclically symmetric equilibrium configuration, settling into a distorted, undesired state instead. Success of the pumpkin balloon for NASA requires a thorough understanding of the phenomenon of multiple stable equilibria and developing of means for the quantitative assessment of design measures that prevent the occurrence of undesired equilibrium. In this paper, we will use the concept of stability to classify cyclically symmetric equilibrium states at full inflation and pressurization. Our mathematical model for a strained equilibrium balloon, when applied to a shape that mimics the Phase IV-A balloon of Flight 517, predicts instability at float. Launched in Spring 2003, this pumpkin balloon failed to deploy properly. Observations on pumpkin shape type super-pressure balloons that date back to the 1980s suggest that within a narrowly defined design class of pumpkin shape super-pressure balloons where individual designs are fully described by the number of gores ng and by a single measure of the bulging gore shape, the designs tend to become more vulnerable with the growing number of gores and with the diminishing size of the bulge radius rB Weight efficiency considerations favor a small bulge radius, while robust deployment into the desired cyclically symmetrical configuration becomes more likely with an increased bulge radius. In an effort to quantify this dependency, we will explore the stability of a family of balloon shapes parametrized by (ng, rB) which includes a design that is very similar, but not identical, to the balloon of Flight 517. In addition, we carry out a number of simulations that demonstrate other aspects related to multiple equilibria of pumpkin balloons.

  10. Aspirin Versus Aspirin Plus Clopidogrel as Antithrombotic Treatment Following Transcatheter Aortic Valve Replacement With a Balloon-Expandable Valve: The ARTE (Aspirin Versus Aspirin + Clopidogrel Following Transcatheter Aortic Valve Implantation) Randomized Clinical Trial.

    Science.gov (United States)

    Rodés-Cabau, Josep; Masson, Jean-Bernard; Welsh, Robert C; Garcia Del Blanco, Bruno; Pelletier, Marc; Webb, John G; Al-Qoofi, Faisal; Généreux, Philippe; Maluenda, Gabriel; Thoenes, Martin; Paradis, Jean-Michel; Chamandi, Chekrallah; Serra, Vicenç; Dumont, Eric; Côté, Mélanie

    2017-07-10

    The aim of this study was to compare aspirin plus clopidogrel with aspirin alone as antithrombotic treatment following transcatheter aortic valve replacement (TAVR) for the prevention of ischemic events, bleeding events, and death. Few data exist on the optimal antithrombotic therapy following TAVR. This was a randomized controlled trial comparing aspirin (80 to 100 mg/day) plus clopidogrel (75 mg/day) (dual antiplatelet therapy [DAPT]) versus aspirin alone (single-antiplatelet therapy [SAPT]) in patients undergoing TAVR with a balloon-expandable valve. The primary endpoint was the occurrence of death, myocardial infarction (MI), stroke or transient ischemic attack, or major or life-threatening bleeding (according to Valve Academic Research Consortium 2 definitions) within the 3 months following the procedure. The trial was prematurely stopped after the inclusion of 74% of the planned study population. A total of 222 patients were included, 111 allocated to DAPT and 111 to SAPT. The composite of death, MI, stroke or transient ischemic attack, or major or life-threatening bleeding tended to occur more frequently in the DAPT group (15.3% vs. 7.2%, p = 0.065). There were no differences between groups in the occurrence of death (DAPT, 6.3%; SAPT, 3.6%; p = 0.37), MI (DAPT, 3.6%; SAT, 0.9%; p = 0.18), or stroke or transient ischemic attack (DAPT, 2.7%; SAPT, 0.9%; p = 0.31) at 3 months. DAPT was associated with a higher rate of major or life-threatening bleeding events (10.8% vs. 3.6% in the SAPT group, p = 0.038). There were no differences between groups in valve hemodynamic status post-TAVR. This small trial showed that SAPT (vs. DAPT) tended to reduce the occurrence of major adverse events following TAVR. SAPT reduced the risk for major or life-threatening events while not increasing the risk for MI or stroke. Larger studies are needed to confirm these results. (Aspirin Versus Aspirin + Clopidogrel Following Transcatheter Aortic Valve Implantation: The ARTE

  11. Weather Balloon Ascent Rate

    Science.gov (United States)

    Denny, Mark

    2016-05-01

    The physics of a weather balloon is analyzed. The surprising aspect of the motion of these balloons is that they ascend to great altitudes (typically 35 km) at a more or less constant rate. Such behavior is not surprising near the ground—say for a helium-filled party balloon rising from street level to the top of the Empire State building—but it is unexpected for a balloon that rises to altitudes where the air is rarefied. We show from elementary physical laws why the ascent rate is approximately constant.

  12. Preoperative predictors of blood component transfusion in living donor liver transplantation

    Directory of Open Access Journals (Sweden)

    R N Makroo

    2013-01-01

    Full Text Available Context: Extensive bleeding associated with liver transplantation is a major challenge faced by transplant surgeons, worldwide. Aims: To evaluate the blood component consumption and determine preoperative factors that predict the same in living donor liver transplantation (LDLT. Settings and Design: This prospective study was performed for a 1 year period, from March 2010 to February 2011. Materials and Methods: Intra- and postoperative utilization of blood components in 152 patients undergoing LDLT was evaluated and preoperative patient parameters like age, gender, height, weight, disease etiology, hemoglobin (Hb, hematocrit (Hct, platelet count (Plt, total leukocyte count (TLC, activated partial thromboplastin time (aPTT, international normalized ratio (INR, serum bilirubin (T. bilirubin, total proteins (T. proteins, albumin to globulin ratio (A/G ratio, serum creatinine (S. creatinine, blood urea (B. urea, and serum electrolytes were assessed to determine their predictive values. Univariate and stepwise discriminant analysis identified those factors, which could predict the consumption of each blood component. Results: The average utilization of packed red cells (PRCs, cryoprecipitates (cryo, apheresis platelets, and fresh frozen plasma was 8.48 units, 2.19 units, 0.93 units, and 2,025 ml, respectively. Disease etiology and blood component consumption were significantly correlated. Separate prediction models which could predict consumption of each blood component in intra and postoperative phase of LDLT were derived from among the preoperative Hb, Hct, model for end-stage liver disease (MELD score, body surface area (BSA, Plt, T. proteins, S. creatinine, B. urea, INR, and serum sodium and chloride. Conclusions: Preoperative variables can effectively predict the blood component requirements during liver transplantation, thereby allowing blood transfusion services in being better prepared for surgical procedure.

  13. Is tube repair of aortic aneurysm followed by aneurysmal change in the common iliac arteries?

    Science.gov (United States)

    Provan, J L; Fialkov, J; Ameli, F M; St Louis, E L

    1990-10-01

    To address the concern that tube repair of an abdominal aortic aneurysm might be followed by aneurysmal change in the common iliac arteries, 23 patients who had undergone the operation were re-examined 3 to 5 years later. Although 9 had had minimal ectasia of these arteries preoperatively, in none of the 23 was there symptomatic or radiologic evidence of aneurysmal change on follow-up. Measurements of the maximum intraluminal diameters were made by computed tomography; they indicated no significant differences between the preoperative and follow-up sizes of the common iliac arteries. The variation in time to follow-up also showed no significant correlation with change in artery diameter.

  14. Are preoperative histology and MRI useful for classification of endometrial cancer risk?

    International Nuclear Information System (INIS)

    Body, Noemie; Lavoué, Vincent; De Kerdaniel, Olivier; Foucher, Fabrice; Henno, Sébastien; Cauchois, Aurélie; Laviolle, Bruno; Leblanc, Marc; Levêque, Jean

    2016-01-01

    The 2010 guidelines of the French National Cancer Institute (INCa) classify patients with endometrial cancer into three risk groups for lymph node invasion and recurrence on the basis of MRI and histological analysis of an endometrial specimen obtained preoperatively. The classification guides therapeutic choices, which may include pelvic and/or para-aortic lymphadenectomy. The purpose of this study was to evaluate the diagnostic performance of preoperative assessment to help identify intermediate- or high-risk patients requiring lymphadenectomy. The study included all patients who underwent surgery for endometrial cancer between January 2010 and December 2013 at either Rennes University Hospital or Vannes Regional Hospital. The criteria for eligibility included a preoperative assessment with MRI and histological examination of an endometrial sample. A histological comparison was made between the preoperative and surgical specimens. Among the 91 patients who underwent a full preoperative assessment, the diagnosis of intermediate- or high-risk endometrial cancer was established by MRI and histology with a sensitivity of 70 %, specificity of 82 %, positive predictive value (PPV) of 87 %, negative predictive value (NPV) of 61 %, positive likelihood ratio (LR+) of 3.8 and negative likelihood ratio (LR-) of 0.3. The risk group was underestimated in 32 % of patients and overestimated in 7 % of patients. MRI underestimated endometrial cancer stage in 20 % of cases, while endometrial sampling underestimated the histological type in 4 % of cases and the grade in 9 % of cases. The preoperative assessment overestimated or underestimated the risk of recurrence in nearly 40 % of cases, with errors in lesion type, grade or stage. Erroneous preoperative risk assessment leads to suboptimal initial surgical management of patients with endometrial cancer

  15. Early Diastolic Strain Rate in Relation to Systolic and Diastolic Function and Prognosis in Aortic Stenosis

    DEFF Research Database (Denmark)

    Dahl, Jordi S; Barros-Gomes, Sergio; Videbæk, Lars

    2016-01-01

    OBJECTIVES: This study examined the impact of early mitral inflow velocity-to-early diastolic strain rate (E/SRe) ratio on long-term outcome after aortic valve replacement (AVR) in aortic stenosis (AS). BACKGROUND: In AS, increased filling pressures are associated with a poor prognosis and can...... be estimated using the early diastolic mitral inflow velocity-to-early diastolic velocity of the mitral annulus (E/e') ratio. Recent studies suggest that the E/SRe ratio surpasses the E/e' ratio in estimating outcome. METHODS: Pre-operative evaluation was performed in 121 patients with severe AS (aortic valve...... area 40% who were scheduled for AVR. Patients were divided according to E/SRe median and followed for 5 years. The primary endpoint was overall mortality. RESULTS: LVEF was lower (53 ± 7% vs. 56 ± 7%, respectively; p = 0.03) and a restrictive...

  16. Reinforced aortic root reconstruction for acute type A aortic dissection involving the aortic root

    Directory of Open Access Journals (Sweden)

    Han Qing-qi

    2013-06-01

    Full Text Available OBJECTIVE: There are debates regarding the optimal approach for AAAD involving the aortic root. We described a modified reinforced aortic root reconstruction approach for treating AAAD involving the aortic root. METHODS: A total of 161 patients with AAAD involving the aortic root were treated by our modified reinforced aortic root reconstruction approach from January 1998 to December 2008. Key features of our modified approach were placement of an autologous pericardial patch in the false lumen, lining of the sinotubular junction lumen with a polyester vascular ring, and wrapping of the vessel with Teflon strips. Outcome measures included post-operative mortality, survival, complications, and level of aortic regurgitation. RESULTS: A total of 161 patients were included in the study (mean age: 43.3 1 15.5 years. The mean duration of follow-up was 5.1 1 2.96 years (2-12 years. A total of 10 (6.2% and 11 (6.8% patients died during hospitalization and during follow-up, respectively. Thirty-one (19.3% patients experienced postoperative complications. The 1-, 3-, 5-, and 10-year survival rates were 99.3%, 98%, 93.8%, and 75.5%, respectively. There were no instances of recurrent aortic dissection, aortic aneurysm, or pseudoaneurysm during the entire study period. The severity of aortic regurgitation dramatically decreased immediately after surgery (from 28.6% to 0% grade 3-4 and thereafter slightly increased (from 0% to 7.2% at 5 years and 9.1% at 10 years. CONCLUSION: This modified reinforced aortic root reconstruction was feasible, safe and durable/effective, as indicated by its low mortality, low postoperative complications and high survival rate.

  17. [Right patent ductus arteriosus with an ipsilateral aortic arch: percutaneous closure with amplatzer devices].

    Science.gov (United States)

    Santiago, Justo; Acuña, Manuel; Arispe, Elizabeth; Camargo, Ronaldo; Neves, Juliana; Arnoni, Daniel; Fontes, Valmir F; Pedra, Carlos A

    2007-03-01

    The association of a right aortic arch with an ipsilateral patent ductus arteriosus is rare, especially when there are no other intracardiac anomalies. We report three female patients aged 26, 35 and 9 years with this combination in whom previous attempts at surgical closure by thoracotomy and sternotomy were unsuccessful and who subsequently underwent successful percutaneous closure of the defects using Amplatzer devices. In two patients, although angiography demonstrated the presence of type-A patent ductus arteriosus, it was not possible to determine the minimum diameter accurately and it was necessary to measure it using a sizing balloon. An Amplatzer duct occluder was used in two patients and an Amplatzer muscular ventricular septal defect occluder, in the other. In all patients, full closure was confirmed in the catheterization laboratory and the patients were discharged on the same day with no complications. Percutaneous closure of a right patent ductus arteriosus associated with a right aortic arch is feasible, safe and effective.

  18. Development of a New Intravascular Low-Profile Device for Exclusion of Aortic Aneurysm: An Experimental Pilot Study

    International Nuclear Information System (INIS)

    Strecker, Ernst-Peter; Haberstroh, Joerg; Boos, Irene; Metz, Stephan; Langer, Mathias; Moliner, Manuel Maynar

    2004-01-01

    Purpose: To present a new intravascular device for the treatment of aorto-iliac aneurysms. Methods: This new device was tested in five dogs with abdominal aortic aneurysm created experimentally by overdilation of a balloon-expandable stent with a 16 or 18 mm wide PTA balloon catheter. The design of the device is based on a self-expanding aortic stent which consists of two stretchable circular frames filled with a textile Dacron mesh membrane that is suspended horizontally into the infrarenal abdominal aorta proximally to the aneurysm. The frames are part of a preshaped double helical structure that is introduced longitudinally through a catheter in a parallel fashion and forming the desired shape at the vessel site to be occluded. Two iliac stent-grafts are introduced in a low-profile status through the membrane sealing the aneurysm sac and holding the stent-grafts in place. After stent-graft expansion, a new bifurcation located more proximally than the natural one is created. The follow-up of the dogs was performed clinically and angiographically, and specimens were evaluated histomorphologically. Results: The membrane device can be introduced through a 9 Fr vascular sheath. Technical success was achieved in four of five dogs. Nine of ten stent-grafts could be fixed securely within the membrane, thus preventing dislocation. Aneurysms were excluded immediately, and blood flow to the external iliac arteries was restored by the stent-grafts. At 6-9 months follow-up of technically successful implanted devices, there were no endoleaks, no migration, no stenoses at contact sites between the implant material and vascular wall, and no stenosis or occlusion of the stent-grafts. At microscopic evaluation, the interspace between the membranes was filled with thrombotic material, thus ensuring exclusion of the aneurysm. Conclusion: This new device was found to be flexible, low profile and useful in excluding abdominal aortic aneurysm in the experimental setting

  19. Safety of minimally invasive mitral valve surgery without aortic cross-clamp.

    Science.gov (United States)

    Umakanthan, Ramanan; Leacche, Marzia; Petracek, Michael R; Kumar, Sathappan; Solenkova, Nataliya V; Kaiser, Clayton A; Greelish, James P; Balaguer, Jorge M; Ahmad, Rashid M; Ball, Stephen K; Hoff, Steven J; Absi, Tarek S; Kim, Betty S; Byrne, John G

    2008-05-01

    We developed a technique for open heart surgery through a small (5 cm) right-anterolateral thoracotomy without aortic cross-clamp. One hundred and ninety-five consecutive patients (103 male and 92 female), age 69 +/- 8 years, underwent surgery between January 2006 and July 2007. Mean preoperative New York Heart Association function class was 2.2 +/- 0.7. Thirty-five patients (18%) had an ejection fraction 0.35 or less. Cardiopulmonary bypass was instituted through femoral (176 of 195, 90%), axillary (18 of 195, 9%), or direct aortic (1 of 195, 0.5%) cannulation. Under cold fibrillatory arrest (mean temperature 28.2 degrees C) without aortic cross-clamp, mitral valve repair (72 of 195, 37%), mitral valve replacement (117 of 195, 60%), or other (6 of 195, 3%) procedures were performed. Concomitant procedures included maze (45 of 195, 23%), patent foramen ovale closure (42 of 195, 22%) and tricuspid valve repair (16 of 195, 8%), or replacement (4 of 195, 2%). Thirty-day mortality was 3% (6 of 195). Duration of fibrillatory arrest, cardiopulmonary bypass, and "skin to skin" surgery were 88 +/- 32, 118 +/- 52, and 280 +/- 78 minutes, respectively. Ten patients (5%) underwent reexploration for bleeding and 44% did not receive any blood transfusions. Six patients (3%) sustained a postoperative stroke, eight (4%) developed low cardiac output syndrome, and two (1%) developed renal failure requiring hemodialysis. Mean length of hospital stay was 7 +/- 4.8 days. This simplified technique of minimally invasive open heart surgery is safe and easily reproducible. Fibrillatory arrest without aortic cross-clamping, with coronary perfusion against an intact aortic valve, does not increase the risk of stroke or low cardiac output. It may be particularly useful in higher risk patients in whom sternotomy with aortic clamping is less desirable.

  20. Scientific Ballooning in India - Recent Developments

    Science.gov (United States)

    Manchanda, R. K.; Srinivasan, S.; Subbarao, J. V.

    Established in 1972, the National Balloon Facility operated by TIFR in Hyderabad, India is is a unique facility in the country, which provides a complete solution in scientific ballooning. It is also one of its kind in the world since it combines both, the in-house balloon production and a complete flight support for scientific ballooning. With a large team working through out the year to design, fabricate and launch scientific balloons, the Hyderabad Facility is a unique centre of expertise where the balloon design, Research and Development, the production and launch facilities are located under one roof. Our balloons are manufactured from 100% indigenous components. The mission specific balloon design, high reliability control and support instrumentation, in-house competence in tracking, telemetry, telecommand, data processing, system design and mechanics is a hallmark of the Hyderabad balloon facility. In the past few years we have executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to size of 780,000 M^3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years will be presented along with the plans for new facilities.

  1. Postoperative Outcomes of Mitral Valve Repair for Mitral Restenosis after Percutaneous Balloon Mitral Valvotomy

    Directory of Open Access Journals (Sweden)

    Seong Lee

    2015-10-01

    Full Text Available Background: There have been a number of studies on mitral valve replacement and repeated percutaneous mitral balloon valvotomy for mitral valve restenosis after percutaneous mitral balloon valvotomy. However, studies on mitral valve repair for these patients are rare. In this study, we analyzed postoperative outcomes of mitral valve repair for mitral valve restenosis after percutaneous mitral balloon valvotomy. Methods: In this study, we assessed 15 patients (mean age, 47.7±9.7 years; 11 female and 4 male who underwent mitral valve repair between August 2008 and March 2013 for symptomatic mitral valve restenosis after percutaneous mitral balloon valvotomy. The mean interval between the initial percutaneous mitral balloon valvotomy and the mitral valve repair was 13.5±7 years. The mean preoperative Wilkins score was 9.4±2.6. Results: The mean mitral valve area obtained using planimetry increased from 1.16±0.16 cm2 to 1.62±0.34 cm2 (p=0.0001. The mean pressure half time obtained using Doppler ultrasound decreased from 202.4±58.6 ms to 152±50.2 ms (p=0.0001. The mean pressure gradient obtained using Doppler ultrasound decreased from 9.4±4.0 mmHg to 5.8±1.5 mmHg (p=0.0021. There were no early or late deaths. Thromboembolic events or infective endocarditis did not occur. Reoperations such as mitral valve repair or mitral valve replacement were not performed during the follow-up period (39±16 months. The 5-year event-free survival was 56.16% (95% confidence interval, 47.467–64.866. Conclusion: On the basis of these results, we could not conclude that mitral valve repair could be an alternative for patients with mitral valve restenosis after percutaneous balloon mitral valvotomy. However, some patients presented with results similar to those of mitral valve replacement. Further studies including more patients with long-term follow-up are necessary to determine the possibility of this application of mitral valve repair.

  2. Determination of entry site for acute type A aortic dissection by initial enhanced CT-scan

    International Nuclear Information System (INIS)

    Mase, Takenori; Narumiya, Chihiro; Aoyama, Takahiko; Nagata, Yoshihisa

    2002-01-01

    Acute type A aortic dissection presents a surgical emergency because conservative therapy is not effective in the majority of instances. Enhanced CT-scan of the chest is commonly available and is considered to be an optimal diagnostic method for this disease. The operative strategy is to resect the primary tear to close the entry site of the aortic dissection and replace it with a tubular Dacron graft. Therefore, the existence of the entry site is important in determining the operative procedure. Based on the numerical value of the enhanced CT-scan inspection, the present study seeks to preoperatively identify the location of the presumed entry site in aortic dissection. From May 1996 to June 1999, 21 consecutive patients (Marfan's syndrome excluded) with acute type A aortic dissection underwent surgical treatment. Nineteen patients were preoperatively examined by enhanced CT-scan: 11 men and 8 women, with a mean age of 61 years. CT-scan slices used for early diagnosis were of the ascending aorta, aortic arch, descending aorta, and thoracoabdominal aorta. The largest diameters of the whole and true lumen were measured from cross-sectional aortic images with a personal computer, and the areas of the whole and true lumen were obtained by the manual tracing method. The true ratio was calculated for the largest diameter and area of the whole lumen. The nineteen patients were divided into two groups according to the location of the entry site based on the operating views. Seven patients with the entry site in the ascending aorta were classified as group A, and twelve patients with the entry site further in the aortic arch and descending aorta were classified as group B. Comparisons were performed by non-parametric analysis. Moreover, a discriminant analysis was applied to evaluate the classification between the two groups. The ratio of the largest diameter of the true lumen in group A at the level of the ascending and descending aorta was significantly greater than that

  3. Determination of entry site for acute type A aortic dissection by initial enhanced CT-scan

    Energy Technology Data Exchange (ETDEWEB)

    Mase, Takenori; Narumiya, Chihiro; Aoyama, Takahiko; Nagata, Yoshihisa [Aichi Medical Univ., Nagakute (Japan). School of Medicine

    2002-01-01

    Acute type A aortic dissection presents a surgical emergency because conservative therapy is not effective in the majority of instances. Enhanced CT-scan of the chest is commonly available and is considered to be an optimal diagnostic method for this disease. The operative strategy is to resect the primary tear to close the entry site of the aortic dissection and replace it with a tubular Dacron graft. Therefore, the existence of the entry site is important in determining the operative procedure. Based on the numerical value of the enhanced CT-scan inspection, the present study seeks to preoperatively identify the location of the presumed entry site in aortic dissection. From May 1996 to June 1999, 21 consecutive patients (Marfan's syndrome excluded) with acute type A aortic dissection underwent surgical treatment. Nineteen patients were preoperatively examined by enhanced CT-scan: 11 men and 8 women, with a mean age of 61 years. CT-scan slices used for early diagnosis were of the ascending aorta, aortic arch, descending aorta, and thoracoabdominal aorta. The largest diameters of the whole and true lumen were measured from cross-sectional aortic images with a personal computer, and the areas of the whole and true lumen were obtained by the manual tracing method. The true ratio was calculated for the largest diameter and area of the whole lumen. The nineteen patients were divided into two groups according to the location of the entry site based on the operating views. Seven patients with the entry site in the ascending aorta were classified as group A, and twelve patients with the entry site further in the aortic arch and descending aorta were classified as group B. Comparisons were performed by non-parametric analysis. Moreover, a discriminant analysis was applied to evaluate the classification between the two groups. The ratio of the largest diameter of the true lumen in group A at the level of the ascending and descending aorta was significantly greater than

  4. Comparison of pre-operative dGEMRIC imaging with intra-operative findings in femoroacetabular impingement: preliminary findings

    International Nuclear Information System (INIS)

    Bittersohl, Bernd; Apprich, Sebastian; Siebenrock, Klaus A.; Mamisch, Tallal Charles; Hosalkar, Harish S.; Werlen, Stefan A.

    2011-01-01

    To study standard MRI and dGEMRIC in patients with symptomatic FAI undergoing surgical intervention and compare them with intra-operative findings to see if they were corroborative. Sixteen patients with symptomatic FAI that warranted surgical intervention were prospectively studied. All patients underwent plain radiographic series for FAI assessment followed by standard MRI and dGEMRIC. Subsequently, patients were surgically treated with safe dislocation and the joint was evaluated for any macroscopic signs of damaged cartilage. Data were statistically analyzed. A total of 224 zones in 16 patients were evaluated. One hundred and sixteen zones were intra-operatively rated as normal with mean T1 values of 510.1 ms ± 141.2 ms. Eighty zones had evidence of damage with mean T1 values of 453.1 ms ± 113.6 ms. The difference in these T1 values was significant (p = 0.003). Correlation between standard MRI and intra-operative findings was moderate (r = 0.535, p < 0.001). Intra-operative findings revealed more damage than standard MRI. On standard MRI, 68.6% zones were graded normal while 31.4% had evidence of damage. On intra-operative visualization, 56.4% zones were graded normal and 43.6% had evidence of damage. Correlation between dGEMRIC and intra-operative findings turned out to be weak (r = 0.114, p < 0.126). On T1 assessment 31.4% of zones were graded as normal and 68.6% as damaged. dGEMRIC was significantly different between normal and affected cartilage based on intra-operative assessment. The correlation for morphological findings was limited, underestimating defects. By combining morphological with biochemical assessment dGEMRIC may play some role in the future to prognosticate outcomes and facilitate surgical planning and intervention. (orig.)

  5. Clinical impact and risk stratification of balloon angioplasty for femoropopliteal disease in nitinol stenting era: Retrospective multicenter study using propensity score matching analysis

    Directory of Open Access Journals (Sweden)

    Taketsugu Tsuchiya

    2016-07-01

    Full Text Available Objective: Nitinol stenting could bring the better outcome in endovascular therapy for femoropopliteal disease. However, it might be expected that recent marked advances in both device technology and operator technique had led to improved efficacy of balloon angioplasty even in this segment. The aims of this study were to evaluate the clinical impact of balloon angioplasty for femoropopliteal disease and make risk stratification clear by propensity score matching analysis. Methods: Based on the multicenter retrospective data, 2758 patients (balloon angioplasty: 729 patients and nitinol stenting: 2029 patients, those who underwent endovascular therapy for femoropopliteal disease, were analyzed. Results: The propensity score matching procedure extracted a total of 572 cases per group, and the primary patency rate of balloon angioplasty and nitinol stenting groups after matching was significantly the same (77.2% vs 82.7% at 1 year; 62.2% vs 64.3% at 3 years; 47.8% vs 54.3% at 5 years. In multivariate Cox hazard regression analysis, significant predictors for primary patency were diabetes mellitus, regular dialysis, cilostazol use, chronic total occlusion, and intra-vascular ultra-sonography use. The strategy of balloon angioplasty was not evaluated as a significant predictor for the primary patency. After risk stratification using five items (diabetes mellitus, regular dialysis, no use of intra-vascular ultra-sonography, chronic total occlusion, and no use of cilostazol: the DDICC score, the estimated primary patency rates of each group (low, DDICC score 0–2; moderate, DDICC score 3; high risk, DDICC score 4–5 were 88.6%, 78.3%, and 63.5% at 1 year; 75.2%, 60.7%, and 39.8% at 3 years; and 66.0%, 47.1%, and 26.3% at 5 years (p < 0.0001. The primary patency rate of balloon angioplasty and nitinol stenting groups was significantly the same in each risk stratification. Conclusion: This study suggests that balloon angioplasty does

  6. Intraluminal Palmaz stent implantation. First clinical case report on a balloon-expandable vessel prosthesis

    Energy Technology Data Exchange (ETDEWEB)

    Palmaz, J C; Richter, G M; Noeldge, G; Kauffmann, G W; Wenz, W

    1987-12-01

    A 74-year-old patient suffering from severe iliac artery stenosis and claudication was chosen to be the first candidate in the world to receive the Palmaz stent, a balloon-expandable intraluminal stent. This procedure was done in the Department of Radiology, University of Freiburg, FRG. The intervention and postprocedural course were uneventful. His walking distance improved from less than 100 m to unlimited walking capacity. The intra-arterial pressure gradient and ankle-arm pressure ratio also returned to normal.

  7. Successful surgical repair of acute type A aortic dissection without the use of blood products.

    Science.gov (United States)

    Papalexopoulou, N; Attia, R Q; Bapat, V N

    2013-10-01

    We report successful surgical treatment of type A aortic dissection in a Jehovah's Witness without the use of any blood products. An interposition graft replacement of the ascending aorta was carried out. This was under right axillo-atrial cardiopulmonary bypass with antegrade cerebral perfusion via right a subclavian and left carotid cannula for 24 minutes at 28°C. Body temperature was kept at 32°C throughout. Autologous transfusion was deployed using cell salvage and a preoperative haemodilution technique. The patient was given tranexamic acid, desmopressin, recombinant factor VIIa, folic acid and epoetin alfa. Patients who object to transfusion represent a significant challenge, especially those who are at a high risk of coagulopathy associated with inherent aortic dissection leading to perturbed haemodynamics, cardiopulmonary bypass and hypothermic circulatory arrest. Type A aortic dissection repair is possible in patients refusing the use of blood products with blood salvage techniques and synthetic products that can limit the risk of bleeding. Minimal hypothermia is vital to preserve platelet function and avoid coagulopathy. Thus, a combination of normothermic/minimal hypothermia and antegrade cerebral protection with a blood conservation strategy can be deployed for a successful surgical outcome in aortic dissection without transfusion.

  8. Motion and shape change when using an endorectal balloon during prostate radiation therapy

    International Nuclear Information System (INIS)

    Court, Laurence E.; D'Amico, Anthony V.; Kadam, Dnyanesh; Cormack, Robert

    2006-01-01

    Purpose: To investigate motion and shape change when using an endorectal balloon (ERB) in patients receiving radiotherapy for prostate cancer. Methods: In nine patients treated for prostate cancer using an ERB, the anterior wall of the ERB was contoured on right lateral images taken immediately before irradiation, and on left lateral images taken immediately after irradiation. Changes in the contours were used to calculate inter-fraction shape change and inter-imaging motion and shape change. Inter-imaging motion describes changes that occur after the right lateral image is taken that are seen in the left lateral image. Results: Eighty-six percent of all inter-imaging shifts of the anterior wall of the ERB were in the posterior direction (mean: 1.8 mm, 1 SD: 1.8 mm, maximum posterior shift: 2.8-7.2 mm). The inter-fraction shape change (1 SD) of the anterior wall was equivalent to a change in the angle of the balloon of 2.5-5.7 deg., with a range of 8-20 deg., depending on the patient. Inter-imaging shape changes were similar in size. Conclusions: The inter-imaging motion and shape changes may be explained by the patient relaxing some time after insertion of the ERB, indicating that it could be reduced by a waiting period after insertion before irradiation. Development of image-guided localization strategies should consider intra-fraction motion and also inter- and intra-fraction shape change

  9. Is Decellularized Porcine Small Intestine Sub-mucosa Patch Suitable for Aortic Arch Repair?

    Science.gov (United States)

    Corno, Antonio F.; Smith, Paul; Bezuska, Laurynas; Mimic, Branko

    2018-01-01

    Introduction: We reviewed our experience with decellularized porcine small intestine sub-mucosa (DPSIS) patch, recently introduced for congenital heart defects. Materials and Methods: Between 10/2011 and 04/2016 a DPSIS patch was used in 51 patients, median age 1.1 months (5 days to 14.5 years), for aortic arch reconstruction (45/51 = 88.2%) or aortic coarctation repair (6/51 = 11.8%). All medical records were retrospectively reviewed, with primary endpoints interventional procedure (balloon dilatation) or surgery (DPSIS patch replacement) due to patch-related complications. Results: In a median follow-up time of 1.5 ± 1.1 years (0.6–2.3years) in 13/51 patients (25.5%) a re-intervention, percutaneous interventional procedure (5/51 = 9.8%) or re-operation (8/51 = 15.7%) was required because of obstruction in the correspondence of the DPSIS patch used to enlarge the aortic arch/isthmus, with median max velocity flow at Doppler interrogation of 4.0 ± 0.51 m/s. Two patients required surgery after failed interventional cardiology. The mean interval between DPSIS patch implantation and re-intervention (percutaneous procedure or re-operation) was 6 months (1–17 months). While there were 3 hospital deaths (3/51 = 5.9%) not related to the patch implantation, no early or late mortality occurred for the subsequent procedure required for DPSIS patch interventional cardiology or surgery. The median max velocity flow at Doppler interrogation through the aortic arch/isthmus for the patients who did not require interventional procedure or surgery was 1.7 ± 0.57 m/s. Conclusions: High incidence of re-interventions with DPSIS patch for aortic arch and/or coarctation forced us to use alternative materials (homografts and decellularized gluteraldehyde preserved bovine pericardial matrix). PMID:29900163

  10. Two cases of upper gingival cancer with a new superselective intra-arterial chemotherapy method from superficial temporal artery. Combined with arterial redistribution and preoperative embolization

    International Nuclear Information System (INIS)

    Tange, Kazuhisa; Fukuta, Kohta; Higa, Teruo

    2007-01-01

    We have begun to apply arterial redistribution and preoperative embolization in superselective intra-arterial chemotherapy from the superficial temporal artery. This study examines two typical cases of upper gingival cancer. Case 1 was a male, age 61, with T4N0M0 upper gingival cancer. Drug dosage began with 50-100 mg/m 2 /day of 5-fluorouracil (FU), while 15 mg/m 2 /hour of Docetaxel was also given once a week for three weeks. At the same time, radiation therapy with a total of 30 Gy (2 Gy at a time) was given. Immediately before the operation, embolization in the internal maxillary artery was performed in order to limit bleeding. Case 2 was a female, age 73, with T3N0M0 upper gingival cancer. This patient was also given 5-FU and Docetaxel for four weeks respectively with a total of 40 Gy radiation therapy. No operation was performed. Both cases gained complete response (CR) with a sole side effect of grade 3 mucositis. Superselective intra-arterial chemotherapy with arterial redistribution in the oral area is highly effective due to local, concentrated dosage of anticancer drug and reduced side effects. It is a promising method to replace surgical operation especially in cases of upper gingival cancer, whose tumor is often limited to the internal maxillary artery alone. (author)

  11. Decreased expression of fibulin-4 in aortic wall of aortic dissection.

    Science.gov (United States)

    Huawei, P; Qian, C; Chuan, T; Lei, L; Laing, W; Wenlong, X; Wenzhi, L

    2014-02-01

    In this research, we will examine the expression of Fibulin-4 in aortic wall to find out its role in aortic dissection development. The samples of aortic wall were obtained from 10 patients operated for acute ascending aortic dissection and five patients for chronic ascending aortic dissection. Another 15 pieces of samples from patients who had coronary artery bypass were as controls. The aortic samples were stained with aldehyde magenta dyeing to evaluate the arrangement of elastic fibers. The Fibulin-4 protein and mRNA expression were both determined by Western blot and realtime quantitative polymerase chain reaction. Compared with the control group, both in acute and chronic ascending aortic dissection, elastic fiber fragments increased and the expression of fibulin-4 protein significantly decreased (P= 0.045 < 0.05). The level of fibulin-4 mRNA decreased in acute ascending aortic dissection (P= 0.034 < 0.05), while it increased in chronic ascending aortic dissection (P=0.004 < 0.05). The increased amounts of elastic fiber fragments were negatively correlated with the expression of fibulin-4 mRNA in acute ascending aortic dissection. In conclusion, in aortic wall of ascending aortic dissection, the expression of fibulin-4 protein decreased and the expression of fibulin-4 mRNA was abnormal. Fibulin-4 may play an important role in the pathogenesis of aortic dissection.

  12. Scientific ballooning in India Recent developments

    Science.gov (United States)

    Manchanda, R. K.

    Established in 1971, the National Balloon Facility operated by TIFR in Hyderabad, India, is a unique facility in the country, which provides a complete solution in scientific ballooning. It is also one of its kind in the world since it combines both, the in-house balloon production and a complete flight support for scientific ballooning. With a large team working through out the year to design, fabricate and launch scientific balloons, the Hyderabad Facility is a unique centre of expertise where the balloon design, research and development, the production and launch facilities are located under one roof. Our balloons are manufactured from 100% indigenous components. The mission specific balloon design, high reliability control and support instrumentation, in-house competence in tracking, telemetry, telecommand, data processing, system design and mechanics is its hallmark. In the past few years, we have executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to 780,000 m 3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years will be presented along with the plans for new facilities.

  13. Reoperative Aortic Root Replacement in Patients with Previous Aortic Root or Aortic Valve Procedures

    Directory of Open Access Journals (Sweden)

    Byung Kwon Chong

    2016-08-01

    Full Text Available Background: Generalization of standardized surgical techniques to treat aortic valve (AV and aortic root diseases has benefited large numbers of patients. As a consequence of the proliferation of patients receiving aortic root surgeries, surgeons are more frequently challenged by reoperative aortic root procedures. The aim of this study was to evaluate the outcomes of redo-aortic root replacement (ARR. Methods: We retrospectively reviewed 66 patients (36 male; mean age, 44.5±9.5 years who underwent redo-ARR following AV or aortic root procedures between April 1995 and June 2015. Results: Emergency surgeries comprised 43.9% (n=29. Indications for the redo-ARR were aneurysm (n=12, pseudoaneurysm (n=1, or dissection (n=6 of the residual native aortic sinus in 19 patients (28.8%, native AV dysfunction in 8 patients (12.1%, structural dysfunction of an implanted bioprosthetic AV in 19 patients (28.8%, and infection of previously replaced AV or proximal aortic grafts in 30 patients (45.5%. There were 3 early deaths (4.5%. During follow- up (median, 54.65 months; quartile 1–3, 17.93 to 95.71 months, there were 14 late deaths (21.2%, and 9 valve-related complications including reoperation of the aortic root in 1 patient, infective endocarditis in 3 patients, and hemorrhagic events in 5 patients. Overall survival and event-free survival rates at 5 years were 81.5%±5.1% and 76.4%±5.4%, respectively. Conclusion: Despite technical challenges and a high rate of emergency conditions in patients requiring redo-ARR, early and late outcomes were acceptable in these patients.

  14. Evaluation of chemokine receptors (CCRs expression on peripheral blood T-lymphocyte subsets in patients with thoracic aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Kaushal Kishore Tiwari

    2016-03-01

    Full Text Available Background & Objectives: Mortality and morbidity from the complication of aortic aneurysm remain very high. Aortic size index, which classify thoracic aortic aneurysm patients in three risk groups for aortic rupture prediction. Recent data support that aortic wall remodeling is a dynamic process with active involvement of the chronic inflammation and immunological system. Aim of our study is to evaluate expression level of chemokine receptors known to be involved in the T-cells migration and to correlate them with aortic size index. Materials & Methods: Total 20 patients undergoing surgery for ascending aortic aneurysm and/or aortic valve surgery were enrolled. Aortic size index was calculated. Preoperatively blood samples collected. By flowcytometry and dual parameter dot plot technology percentage of positivity of CCR5 on these T-cell subsets were quantified. Results: Mean age of the patients was 67±5.93 years. Majority of patients had hypertension. Mean ascending aortic diameter was 42.1±8.14 mm. Mean Aortic size Index was 22.21±3.38 mm/m2. A statistical significance has observed between aortic size index and the expression of CCR5 on total CD4 positive T-cells (p-0.0949, and between aortic size index and CCR5 expression on the total CD3 positive T-cells (p-0.0293. Significant correlation observed between ASI and CCR5 expression on the CD8+/CD3+ T-cell subset (p-0.0183. Similarly, strong positive relationship between ASI and the expression of CCR5 on the cytotoxic CD28-/CD4+ T-cell subset (p-0.0055. Activated state of cytotoxic CD28-/CD4+ cell also correlated with aortic size index (p-0.0668.Conclusion: We conclude that T-cell mediated cytotoxic mechanism driven by CCR5 play an important role in the pathophysiology of the thoracic aortic aneurysm.JCMS Nepal. 2016;12(1:23-27.

  15. Long-term results of aortic valve replacement with Edwards Prima Plus stentless bioprosthesis: eleven years' follow up.

    Science.gov (United States)

    Auriemma, Stefano; D'Onofrio, Augusto; Brunelli, Massimo; Magagna, Paolo; Paccanaro, Mariemma; Rulfo, Fanny; Fabbri, Alessandro

    2006-09-01

    The Edwards Lifesciences Prima Plus stentless valve (ELSV) is a bioprosthesis manufactured from a porcine aortic root. The study aim was to evaluate late clinical outcomes after aortic valve replacement (AVR) with ELSV implanted as a miniroot in patients with aortic valve disease. Between 1993 and 2004, 318 patients (232 males, 86 females; mean age 69 +/- 9 years; range: 37-83 years) underwent AVR with the ELSV. Preoperatively, 102 patients (32%), 162 (51%) and 54 (17%) were in NYHA classes I/II, III and IV, respectively. Aortic stenosis, aortic regurgitation and combined lesions were present in 124 patients (39%), 114 (36%) and 41 (13%), respectively. Twenty patients (6%) were referred for an acute aortic dissection, 20 (6%) for an aortic root aneurysm, and 139 (44%) had an associated aneurysmal dilatation of the ascending aorta. The ascending aorta was replaced in 159 patients (50%); aortic arch replacement was required in 10 (3%). Coronary artery bypass graft was performed in 86 patients (27%). The follow up was based on clinical data. Operative mortality was 5% (n = 17). There were 49 late deaths (5.2%/pt-yr). Valve-related mortality occurred in 10 patients (1%/pt-yr). Actuarial survival at five and 10 years was 78% and 33%, respectively. Actuarial freedom from valve reoperation and structural valve deterioration at 10 years were 100% and 64%. Actuarial freedom from embolic events and endocarditis at 10 years were 84% and 81%, respectively. The ELSV, when implanted as a miniroot, provided good early and long-term results in terms of survival and freedom from major complications.

  16. Assessment of structural valve deterioration of transcatheter aortic bioprosthetic balloon-expandable valves using the new European consensus definition.

    Science.gov (United States)

    Eltchaninoff, Hélène; Durand, Eric; Avinée, Guillaume; Tron, Christophe; Litzler, Pierre-Yves; Bauer, Fabrice; Dacher, Jean-Nicolas; Werhlin, Camille; Bouhzam, Najime; Bettinger, Nicolas; Candolfi, Pascal; Cribier, Alain

    2018-03-30

    Durability of transcatheter aortic bioprosthetic valves remains a major issue. Standardised definitions of deterioration and failure of bioprosthetic valves have recently been proposed. The aim of this study was to assess structural transcatheter valve deterioration (SVD) and bioprosthetic valve failure (BVF) using these new definitions. All TAVI patients implanted up to September 2012 with a minimal theoretical five-year follow-up were included. Systematic clinical and echocardiographic follow-up was performed annually. New standardised definitions were used to assess durability of transcatheter aortic bioprosthetic valves. From 2002 to 2012, 378 patients were included. Mean age and logistic EuroSCORE were 83.3±6.8 years and 22.8±13.1%. Thirty-day mortality was 13.2%. Nine patients had SVD including two severe forms and two patients had definite late BVF. The incidence of SVD and BVF at eight years was 3.2% (95% CI: 1.45-6.11) and 0.58% (95% CI: 0.15-2.75), respectively. Even though limited by the poor survival of the very high-risk/compassionate early population, our data do not demonstrate any alarm concerning transcatheter aortic valve durability. Careful prospective assessment in younger and lower-risk patients and comparison with surgical bioprosthetic valves are required for further assessment of the long-term durability of transcatheter valves.

  17. Wall stress on ascending thoracic aortic aneurysms with bicuspid compared with tricuspid aortic valve.

    Science.gov (United States)

    Xuan, Yue; Wang, Zhongjie; Liu, Raymond; Haraldsson, Henrik; Hope, Michael D; Saloner, David A; Guccione, Julius M; Ge, Liang; Tseng, Elaine

    2018-03-08

    Guidelines for repair of bicuspid aortic valve-associated ascending thoracic aortic aneurysms have been changing, most recently to the same criteria as tricuspid aortic valve-ascending thoracic aortic aneurysms. Rupture/dissection occurs when wall stress exceeds wall strength. Recent studies suggest similar strength of bicuspid aortic valve versus tricuspid aortic valve-ascending thoracic aortic aneurysms; thus, comparative wall stress may better predict dissection in bicuspid aortic valve versus tricuspid aortic valve-ascending thoracic aortic aneurysms. Our aim was to determine whether bicuspid aortic valve-ascending thoracic aortic aneurysms had higher wall stresses than their tricuspid aortic valve counterparts. Patients with bicuspid aortic valve- and tricuspid aortic valve-ascending thoracic aortic aneurysms (bicuspid aortic valve = 17, tricuspid aortic valve = 19) greater than 4.5 cm underwent electrocardiogram-gated computed tomography angiography. Patient-specific 3-dimensional geometry was reconstructed and loaded to systemic pressure after accounting for prestress geometry. Finite element analyses were performed using the LS-DYNA solver (LSTC Inc, Livermore, Calif) with user-defined fiber-embedded material model to determine ascending thoracic aortic aneurysm wall stress. Bicuspid aortic valve-ascending thoracic aortic aneurysms 99th-percentile longitudinal stresses were 280 kPa versus 242 kPa (P = .028) for tricuspid aortic valve-ascending thoracic aortic aneurysms in systole. These stresses did not correlate to diameter for bicuspid aortic valve-ascending thoracic aortic aneurysms (r = -0.004) but had better correlation to tricuspid aortic valve-ascending thoracic aortic aneurysms diameter (r = 0.677). Longitudinal stresses on sinotubular junction were significantly higher in bicuspid aortic valve-ascending thoracic aortic aneurysms than in tricuspid aortic valve-ascending thoracic aortic aneurysms (405 vs 329 kPa, P = .023). Bicuspid

  18. Ballooning for Biologists: Mission Essentials for Flying Experiments on Large NASA Balloons

    Science.gov (United States)

    Smith, David J.; Sowa, Marianne

    2017-01-01

    Despite centuries of scientific balloon flights, only a handful of experiments have produced biologically-relevant results. Yet unlike orbital spaceflight, it is much faster and cheaper to conduct biology research with balloons, sending specimens to the near space environment of Earths stratosphere. Samples can be loaded the morning of a launch and sometimes returned to the laboratory within one day after flying. The National Aeronautics and Space Administration (NASA) flies large, unmanned scientific balloons from all over the globe, with missions ranging from hours to weeks in duration. A payload in the middle portion of the stratosphere (approx. 35 km above sea level) will be exposed to an environment similar to the surface of Mars: temperatures generally around -36 C, atmospheric pressure at a thin 1 kPa, relative humidity levels <1%, and a harsh illumination of ultraviolet (UV) and cosmic radiation levels (about 100 W/sq m and 0.1 mGy/d, respectively) that can be obtained nowhere else on the surface of the Earth, including environmental chambers and particle accelerator facilities attempting to simulate space radiation effects. Considering the operational advantages of ballooning and the fidelity of space-like stressors in the stratosphere, researchers in aerobiology, astrobiology, and space biology can benefit from balloon flight experiments as an intermediary step on the extraterrestrial continuum (ground, low Earth orbit, and deep space studies). Our presentation targets biologists with no background or experience in scientific ballooning. We will provide an overview of large balloon operations, biology topics that can be uniquely addressed in the stratosphere, and a roadmap for developing payloads to fly with NASA.

  19. Aortic Graft Infection Secondary to Iatrogenic Transcolonic Graft Malposition.

    Science.gov (United States)

    Blank, Jacqueline J; Rothstein, Abby E; Lee, Cheong Jun; Malinowski, Michael J; Lewis, Brian D; Ridolfi, Timothy J; Otterson, Mary F

    2018-01-01

    Aortic graft infections are a rare but devastating complication of aortic revascularization. Often infections occur due to contamination at the time of surgery. Iatrogenic misplacement of the limbs of an aortobifemoral graft is exceedingly rare, and principles of evaluation and treatment are not well defined. We report 2 cases of aortobifemoral bypass graft malposition through the colon. Case 1 is a 54-year-old male who underwent aortobifemoral bypass grafting for acute limb ischemia. He had previously undergone a partial sigmoid colectomy for diverticulitis. Approximately 6 months after vascular surgery, he presented with an occult graft infection. Preoperative imaging and intraoperative findings were consistent with graft placement through the sigmoid colon. Case 2 is a 60-year-old male who underwent aortobifemoral bypass grafting due to a nonhealing wound after toe amputation. His postoperative course was complicated by pneumonia, bacteremia thought to be secondary to the pneumonia, general malaise, and persistent fevers. Approximately 10 weeks after the vascular surgery, he presented with imaging and intraoperative findings of graft malposition through the cecum. Aortic graft infection is usually caused by surgical contamination and presents as an indolent infection. Case 1 presented as such; Case 2 presented more acutely. Both grafts were iatrogenically misplaced through the colon at the index operation. The patients underwent extra-anatomic bypass and graft explantation and subsequently recovered.

  20. Florida Sleeve Procedure Is Durable and Improves Aortic Valve Function in Marfan Syndrome Patients.

    Science.gov (United States)

    Aalaei-Andabili, Seyed Hossein; Martin, Tomas; Hess, Philip; Klodell, Charles; Karimi, Ashkan; Arnaoutakis, George; Lee, Teng; Beaver, Thomas

    2017-09-01

    The Florida sleeve (FS) procedure was developed as a simplified approach for repair of functional type I aortic insufficiency secondary to aortic root aneurysm. We evaluated postoperative aortic valve function, long-term survival, and freedom from reoperation in Marfan syndrome patients who underwent the FS procedure at our center. All Marfan syndrome patients undergoing FS procedure from May 2002 to December 2014 were included. Echocardiography assessment included left ventricular end-diastolic diameter (LVEDD), left ventricular end-systolic diameter (LVESD), ejection fraction, and degree of aortic insufficiency (none = 0, minimal = 1, mild = 2, moderate = 3, severe = 4). Social Security Death Index and primary care physicians' report were used for long-term follow-up. Thirty-seven Marfan syndrome patients, 21 (56.8%) men and 16 (43%) women with mean age of 35.08 ± 13.45 years underwent FL repair at our center. There was no in-hospital or 30-day death or stroke. Two patients required reoperation due to bleeding. Patients' survival rate was 94% at 1 to 8 years. Freedom from reoperation was 100% at 8 years. Twenty-five patients had postoperative follow-up echocardiography at 1 week. Aortic insufficiency grade significantly decreased after the procedure (preoperative mean ± SD: 1.76 ± 1.2 versus 1-week postoperative mean ± SD: 0.48 ± 0.71, p Marfan syndrome patients with immediate improvement in aortic valve function. Long-term survival and freedom from reoperation rates are encouraging. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Evaluation of the results of treatment of morbid obesity by the endoscopic intragastric balloon implantation method.

    Science.gov (United States)

    Żurawiński, Wojciech; Sokołowski, Dariusz; Krupa-Kotara, Karolina; Czech, Elżbieta; Sosada, Krystyn

    2017-01-01

    Overweight and obesity are ranked in the fifth place among the risk factors responsible for the greatest number of deaths in the world. To assess the effects of treatment of patients with morbid obesity using endoscopic intragastric balloon (IGB) implantation. Two hundred and seventy-two patients with obesity were treated using endoscopic intragastric balloon implantation. Upon analysis of the inclusion and exclusion criteria, the study covered a group of 63 patients with morbid obesity. The patients were implanted with the LexBal balloon. Reduction of excess body mass, changes to BMI values and ailments and complications divided into mild and severe were assessed. Before intragastric balloon treatment, the average body mass index (BMI) value was 58.3 ±10.5 kg/m 2 , whereas after 6 months of treatment it decreased to 49.5 ±8.7 kg/m 2 . The patients with postoperative BMI equal to or greater than 50.0 kg/m 2 reported nausea (69.7%), vomiting (51.5%), flatulence (45.5%), upper abdominal pain (36.4%) and general discomfort (424%) more frequently. Dehydration (9.1%) was also more frequent in this group, whereas frequency of occurrence of such ailments and complications as heartburn (23.3%) and oesophageal candidiasis (10.0%) was higher in the patients with postoperative BMI below 50.0 kg/m 2 . Endoscopic intragastric balloon implantation is an effective and safe method of excess body mass reduction in patients with morbid obesity before a planned bariatric surgical procedure. Pre-operative excess body mass and BMI value and post-operative excess weight loss in patients with morbid obesity have no impact on frequency of occurrence of ailments and complications in IGB treatment.

  2. Supra-annular Valve-in-Valve implantation reduces blood stasis on the transcatheter aortic valve leaflets.

    Science.gov (United States)

    Vahidkhah, Koohyar; Azadani, Ali N

    2017-06-14

    Leaflet thrombosis following transcatheter aortic valve replacement (TAVR) and Valve-in-Valve (ViV) procedures has been increasingly recognized. This study aimed to investigate the effect of positioning of the transcatheter aortic valve (TAV) in ViV setting on the flow dynamics aspect of post-ViV thrombosis by quantifying the blood stasis in the intra-annular and supra-annular settings. To that end, two idealized computational models, representing ViV intra-annular and supra-annular positioning of a TAV were developed in a patient-specific geometry. Three-dimensional flow fields were then obtained via fluid-solid interaction modeling to study the difference in blood residence time (BRT) on the TAV leaflets in the two settings. At the end of diastole, a strip of high BRT (⩾1.2s) region was observed on the TAV leaflets in the ViV intra-annular positioning at the fixed boundary where the leaflets are attached to the frame. Such a high BRT region was absent on the TAV leaflets in the supra-annular positioning. The maximum value of BRT on the surface of non-, right, and left coronary leaflets of the TAV in the supra-annular positioning were 53%, 11%, and 27% smaller compared to the intra-annular positioning, respectively. It was concluded that the geometric confinement of TAV by the leaflets of the failed bioprosthetic valve in ViV intra-annular positioning increases the BRT on the leaflets and may act as a permissive factor in valvular thrombosis. The absence of such a geometric confinement in the ViV supra-annular positioning leads to smaller BRT and subsequently less likelihood of leaflet thrombosis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Aortic Annular Enlargement during Aortic Valve Replacement

    Directory of Open Access Journals (Sweden)

    Selman Dumani

    2016-09-01

    Full Text Available In the surgery of aortic valve replacement is always attempted, as much as possible, to implant the larger prosthesis with the mains goals to enhance the potential benefits, to minimise transvalvular gradient, decrease left ventricular size and avoid the phenomenon of patient-prosthesis mismatch. Implantation of an ideal prosthesis often it is not possible, due to a small aortic annulus. A variety of aortic annulus enlargement techniques is reported to avoid patient-prosthesis mismatch. We present the case that has submitted four three times open heart surgery. We used Manouguian technique to enlarge aortic anulus with excellent results during the fourth time of surgery.

  4. 21 CFR 874.4100 - Epistaxis balloon.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Epistaxis balloon. 874.4100 Section 874.4100 Food... DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4100 Epistaxis balloon. (a) Identification. An epistaxis balloon is a device consisting of an inflatable balloon intended to control internal...

  5. Premedication with oral Dextromethorphan reduces intra-operative Morphine requirement

    Directory of Open Access Journals (Sweden)

    R Talakoub

    2005-09-01

    Full Text Available Background: Intra-operative pain has adverse effects on hemodynamic parameters. Due to complications of opioids for pain relief, using non-opioids medication is preferred. The purpose of this study was to investigate the effect of oral dextrometorphan premedication on intra-operative Morphine requirement. Methods: After approval of the Ethics committee and informed consent, 40 adult patients who stand in American Society of Anesthesiologists Physical Status I and II, under general anesthesia for elective laparatomy were selected and classified in two equal groups randomly. In group A, oral dextromethorphan (60mg was administered at 10 PM and 6 AM preoperatively. In group B, placebo (dextrose was administered. After induction of general anesthesia and before skin incision, intravenous morphine (0.01 mg/kg was administered. During surgery, when systolic blood pressure or heart rate was increased more than 20% of the preoperative baseline, 0.01 mg/kg morphine was administered. At the end of surgery, the totally prescribed morphine (mg/kg and maximal increase in systolic, diastolic, mean arterial blood pressure and heart rate relative to the baseline values were calculated and statistically compared with student’s t-test. Results: The mean dose of administered morphine during surgery was significantly less in group A than group B (P<0.0001. Also, Maximal increase in systolic, diastolic and mean arterial blood pressure was significantly less in group A (p<0.003, p<0.004, p<0.0001, respectively. There was no significant difference in maximal heart rate increase between two groups (p<0.114. Conclusion: Oral dextromethorphan premedication may decrease intra-operative morphine requirement and reduce maximal increase in systolic and mean arterial blood pressure during surgery. Key words: Dextromethorphan, Morphine, Intra-operative, Premedication Hemodynamic

  6. Valve-sparing aortic root replacement and aortic valve repair in a patient with acromegaly and aortic root dilatation

    Directory of Open Access Journals (Sweden)

    Karel Van Praet

    2015-07-01

    Full Text Available Aortic regurgitation and dilatation of the aortic root and ascending aorta are severe complications of acromegaly. The current trend for management of an aortic root aneurysm is valve-sparing root replacement as well as restoring the diameter of the aortic sinotubular junction (STJ and annulus. Our case report supports the recommendation that in patients with acromegaly, severe aortic root involvement may indicate the need for surgery.

  7. Intra-parotid dermoid cyst: excision through a face lift incision.

    Science.gov (United States)

    Shakeel, M; Keh, S M; Chapman, A; Hussain, A

    2014-11-01

    Intra-parotid dermoid cysts are extremely rare. Clinically, they present like any other parotid lump and pre-operative diagnosis is rarely possible. A 62 years old Caucasian man presented with a painless lump in his right parotid region. The Magnetic Resonance Imaging (MRI) scan revealed a 3 x 3 cm mass in the parotid tail. Cytological examination was unhelpful. The patient underwent successful excision of the cyst through a small face lift incision. No drain was inserted and the patient was discharged home the same day. The patient made an uneventful recovery and was highly satisfied with the aesthetic outcome. The definite histopathological diagnosis was an intra-parotid dermoid cyst.

  8. Extra-anatomic revascularization for preoperative cerebral malperfusion due to distal carotid artery occlusion in acute type A aortic dissection.

    Science.gov (United States)

    Luehr, Maximilian; Etz, Christian D; Nozdrzykowski, Michal; Lehmkuhl, Lukas; Misfeld, Martin; Bakhtiary, Farhad; Borger, Michael A; Mohr, Friedrich-Wilhelm

    2016-02-01

    Management of patients with acute aortic dissection type A (AADA) and cerebral malperfusion secondary to occlusion or stenosis of the left common carotid artery (LCCA) or right common carotid artery (RCCA) is a significant challenge. The aim of this study is to present our institutional strategy and postoperative results for this high-risk patient cohort. Between November 2005 and July 2013, 23 of 354 consecutively operated AADA patients [median age: 66.3; interquartile range (IQR): 55.2-69.9] suffered from cerebral malperfusion due to bilateral (n = 1) or unilateral occlusion of the LCCA/RCCA (n = 22). AADA repair comprised hemi- (n = 14) or total (n = 9) arch replacement in combination with aortic valve repair (n = 7) or replacement (n = 11), root replacement (n = 15) and coronary bypass (n = 3). Extra-anatomic aorto-carotid bypass was performed in all patients. Aorto-carotid bypass was performed at the beginning of the procedure to allow for unilateral selective cerebral perfusion (n = 17; 73.9%) or during the procedure if persisting malperfusion was suspected by near-infrared spectroscopy (n = 6; 26.1%). The median follow-up was 15.2 months (IQR: 4.8-34.1) and 100% complete. Median hospital stay and ICU stay were 16.0 (IQR: 12.5-26.0) and 13.7 (IQR: 2.0-16.5) days, respectively. Rethoracotomy for haemorrhage or cardiac tamponade was performed in 6 (26.1%) patients. Other postoperative complications comprised low cardiac output with extracorporeal membrane oxygenation (n = 2; 8.7%), sepsis (n = 4; 17.4%), respiratory insufficiency (n = 10; 43.5%), renal failure with temporary dialysis (n = 7; 30.4%) and visceral malperfusion (n = 2; 8.7%) requiring stent grafting (n = 1) or laparotomy with intestinal resection (n = 1). New stroke with or without permanent sensory or motor deficit was diagnosed in 8 (34.8%) patients. Temporary neurological deficits were seen in 9 (39.1%) individuals. Hospital and 1-year mortality rates were 13.0 and 30.4%, respectively. Overall

  9. Re-operation for aortic and mitral prosthetic dysfunctions.

    Science.gov (United States)

    Kaul, T K; Sastry, M R; Mercer, J L; Meade, J B

    1985-01-01

    The overall incidence of re-operation and prosthetic valve endocarditis was low in the present series as mechanical prostheses were used predominantly. The prosthetic dysfunctions were less frequent following the primary implantation with Bjork Shiley prostheses, but high operative risk was associated with the clotted Bjork Shiley prostheses. We also had unusual experience of strut fracture and sticking of Bjork Shiley discs in the closed position in both aortic and mitral positions. The early deaths were nil since the use of cardioplegic protection. Intra-operative bleeding due to adhesions can be minimised by using synthetic or heterologous pericardium during the primary operation.

  10. Valve-sparing root replacement in children with aortic root aneurysm: mid-term results.

    Science.gov (United States)

    Lange, Rüdiger; Badiu, Catalin C; Vogt, Manfred; Voss, Bernhard; Hörer, Jürgen; Prodan, Zsolt; Schreiber, Christian; Mazzitelli, Domenico

    2013-05-01

    We aimed at evaluating the results of aortic valve-sparing root replacement (AVSRR) in children with aortic root aneurysm (ARA) due to genetic disorders in terms of mortality, reoperation and recurrent aortic valve regurgitation (AVR). Thirteen patients (mean age 9.7 ± 6.5 years, 10 months-18 years) underwent AVSRR for ARA between 2002 and 2011. Six of the 13 patients had Marfan syndrome, 3 Loeys-Dietz syndrome (LDS), 2 bicuspid aortic valve syndrome and 2 an unspecified connective tissue disorder. AVR was graded as none/trace, mild and severe in 5, 7 and 1 patient, respectively. The mean pre-operative root diameter was 45 ± 10 mm (mean Z-score 10.3 ± 2.0). Remodelling of the aortic root was performed in 4 patients, reimplantation of the aortic valve in 9 and a concomitant cusp repair in 4. The diameter of the prostheses used for root replacement varied from 22 to 30 mm (mean Z-score = 2.3 ± 3). The follow-up was 100% complete with a mean follow-up time of 3.7 years. There was no operative mortality. One patient with LDS died 2.5 years after the operation due to spontaneous rupture of the descending aorta. Root re-replacement with mechanical conduit was necessary in 1 patient for severe recurrent AVR 8 days after remodelling of the aortic root. At final follow-up, AVR was graded as none/trace and mild in all patients. Eleven patients presented in New York Heart Association functional Class I and 1 in Class II. In paediatric patients with ARA, valve-sparing root replacement can be performed with low operative risk and excellent mid-term valve durability. Hence, prosthetic valve-related morbidity may be avoided. Due to the large diameters of the aortic root and the ascending aorta, the size of the implanted root prostheses will not limit later growth of the native aorta.

  11. Launching Garbage-Bag Balloons.

    Science.gov (United States)

    Kim, Hy

    1997-01-01

    Presents a modification of a procedure for making and launching hot air balloons made out of garbage bags. Student instructions for balloon construction, launching instructions, and scale diagrams are included. (DDR)

  12. Metabolic and hemodynamic effects of saline infusion to maintain volemia on temporary abdominal aortic occlusion

    Directory of Open Access Journals (Sweden)

    Fábio Ferreira Amorim

    2002-10-01

    Full Text Available OBJECTIVE: To analyze hemodynamic and metabolic effects of saline solution infusion in the maintenance of blood volume in ischemia-reperfusion syndrome during temporary abdominal aortic occlusion in dogs. METHODS: We studied 20 dogs divided into 2 groups: the ischemia-reperfusion group (IRG, n=10 and the ischemia-reperfusion group with saline solution infusion aiming at maintaining mean pulmonary arterial wedge pressure between 10 and 20 mmHg (IRG-SS, n=10. All animals were anesthetized with sodium thiopental and maintained on spontaneous ventilation. Occlusion of the supraceliac aorta was obtained with inflation of a Fogarty catheter inserted through the femoral artery. After 60 minutes of ischemia, the balloon was deflated, and the animals were observed for another 60 minutes of reperfusion. RESULTS: IRG-SS dogs did not have hemodynamic instability after aortic unclamping, and the mean systemic blood pressure and heart rate were maintained. However, acidosis worsened, which was documented by a greater reduction of arterial pH that occurred especially due to the absence of a respiratory response to metabolic acidosis that was greater with the adoption of this procedure. CONCLUSION: Saline solution infusion to maintain blood volume avoided hemodynamic instability after aortic unclamping. This procedure, however, caused worsening in metabolic acidosis in this experimental model.

  13. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI). ...

  14. Correction of aortic insufficiency with an external adjustable prosthetic aortic ring.

    Science.gov (United States)

    Gogbashian, Andrew; Ghanta, Ravi K; Umakanthan, Ramanan; Rangaraj, Aravind T; Laurence, Rita G; Fox, John A; Cohn, Lawrence H; Chen, Frederick Y

    2007-09-01

    Less invasive, valve-sparing options are needed for patients with aortic insufficiency (AI). We sought to evaluate the feasibility of reducing AI with an external adjustable aortic ring in an ovine model. To create AI, five sheep underwent patch plasty enlargement of the aortic annulus and root by placement of a 10 x 15 mm pericardial patch between the right and noncoronary cusps. An adjustable external ring composed of a nylon band was fabricated and placed around the aortic root. Aortic flow, aortic pressure, and left ventricular pressures were measured with the ring loose (off) and tightened (on). Mean regurgitant orifice area decreased by 86%, from 0.07 +/- 0.03 cm2 (ring loose, off) to 0.01 +/- 0.00 cm2 (ring tightened, on) [p < 0.01]. The regurgitant fraction decreased from 18 +/- 4% to 2 +/- 1% [p < 0.01]. The ring did not significantly affect stroke volume and aortic pressure. An ovine model of aortic root dilatation resulting in acute AI has been developed. In this model, application of an external, adjustable constricting aortic ring eliminated AI. An aortic ring may be a useful adjunct in reducing AI secondary to annular dilatation.

  15. Computed tomography-based anatomic characterization of proximal aortic dissection with consideration for endovascular candidacy.

    Science.gov (United States)

    Moon, Michael C; Greenberg, Roy K; Morales, Jose P; Martin, Zenia; Lu, Qingsheng; Dowdall, Joseph F; Hernandez, Adrian V

    2011-04-01

    Proximal aortic dissections are life-threatening conditions that require immediate surgical intervention to avert an untreated mortality rate that approaches 50% at 48 hours. Advances in computed tomography (CT) imaging techniques have permitted increased characterization of aortic dissection that are necessary to assess the design and applicability of new treatment paradigms. All patients presenting during a 2-year period with acute proximal aortic dissections who underwent CT scanning were reviewed in an effort to establish a detailed assessment of their aortic anatomy. Imaging studies were assessed in an effort to document the location of the primary proximal fenestration, the proximal and distal extent of the dissection, and numerous morphologic measurements pertaining to the aortic valve, root, and ascending aorta to determine the potential for an endovascular exclusion of the ascending aorta. During the study period, 162 patients presented with proximal aortic dissections. Digital high-resolution preoperative CT imaging was performed on 76 patients, and 59 scans (77%) were of adequate quality to allow assessment of anatomic suitability for treatment with an endograft. In all cases, the dissection plane was detectable, yet the primary intimal fenestration was identified in only 41% of the studies. Scans showed 24 patients (32%) appeared to be anatomically amenable to such a repair (absence of valvular involvement, appropriate length and diameter of proximal sealing regions, lack of need to occlude coronary vasculature). Of the 42 scans that were determined not to be favorable for endovascular repair, the most common exclusion finding was the absence of a proximal landing zone (n = 15; 36%). Appropriately protocoled CT imaging provides detailed anatomic information about the aortic root and ascending aorta, allowing the assessment of which dissections have proximal fenestrations that may be amenable to an endovascular repair. Copyright © 2011 Society for

  16. Aortic compliance in patients with aortic regurgitation. Evaluation with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Murai, Sachiko; Hamada, Seiki; Ueguchi, Takashi

    2005-01-01

    The purpose of this study was to assess by means of cine magnetic resonance imaging (MRI) aortic compliance before and after aortic valve replacement (AVR with SJM (St. Jude Medical, St paul, MN) valve) in patients with aortic regurgitation (AR). Two groups (healthy controls and patients with severe isolated AR) of 10 subjects each were included in this study. Cine MRI was performed at three locations of the aorta, and aortic compliance was calculated by dividing the maximum change in the aortic area by pulse pressure. Cine MRI is useful to assess abnormalities of aortic compliance in patients with AR. Compared with the control group, aortic compliance in the AR group was significantly less in the ascending aorta (p<0.05), decreasing in order of aortic location. After AVR, aortic compliance improved for all locations. Cine MRI enables assessment of aortic biophysical properties such as a compliance for evaluating the progression of AR and the efficacy of treatment. (author)

  17. Clinical value of regression of electrocardiographic left ventricular hypertrophy after aortic valve replacement.

    Science.gov (United States)

    Yamabe, Sayuri; Dohi, Yoshihiro; Higashi, Akifumi; Kinoshita, Hiroki; Sada, Yoshiharu; Hidaka, Takayuki; Kurisu, Satoshi; Shiode, Nobuo; Kihara, Yasuki

    2016-09-01

    Electrocardiographic left ventricular hypertrophy (ECG-LVH) gradually regressed after aortic valve replacement (AVR) in patients with severe aortic stenosis. Sokolow-Lyon voltage (SV1 + RV5/6) is possibly the most widely used criterion for ECG-LVH. The aim of this study was to determine whether decrease in Sokolow-Lyon voltage reflects left ventricular reverse remodeling detected by echocardiography after AVR. Of 129 consecutive patients who underwent AVR for severe aortic stenosis, 38 patients with preoperative ECG-LVH, defined by SV1 + RV5/6 of ≥3.5 mV, were enrolled in this study. Electrocardiography and echocardiography were performed preoperatively and 1 year postoperatively. The patients were divided into ECG-LVH regression group (n = 19) and non-regression group (n = 19) according to the median value of the absolute regression in SV1 + RV5/6. Multivariate logistic regression analysis was performed to assess determinants of ECG-LVH regression among echocardiographic indices. ECG-LVH regression group showed significantly greater decrease in left ventricular mass index and left ventricular dimensions than Non-regression group. ECG-LVH regression was independently determined by decrease in the left ventricular mass index [odds ratio (OR) 1.28, 95 % confidence interval (CI) 1.03-1.69, p = 0.048], left ventricular end-diastolic dimension (OR 1.18, 95 % CI 1.03-1.41, p = 0.014), and left ventricular end-systolic dimension (OR 1.24, 95 % CI 1.06-1.52, p = 0.0047). ECG-LVH regression could be a marker of the effect of AVR on both reducing the left ventricular mass index and left ventricular dimensions. The effect of AVR on reverse remodeling can be estimated, at least in part, by regression of ECG-LVH.

  18. Acute Type II Aortic Dissection with Severe Aortic Regurgitation and Chronic Descending Aortic Dissection in Pregnant Patient with Marfan Syndrome.

    Science.gov (United States)

    Lee, Seok-Soo; Jung, Tae-Eun; Lee, Dong Hyup

    2012-12-01

    Aortic dilatation and dissection are severe complications during pregnancy that can be fatal to both the mother and the fetus. The risks of these complications are especially high in pregnant patients with Marfan syndrome; however, incidents of descending aortic dissection are very rare. This case report involves a successful Bentall procedure for and recovery from a rare aortic dissection in a pregnant Marfan patient who developed acute type II aortic dissection with severe aortic regurgitation and chronic descending aortic dissection immediately after Cesarean section. Regular follow-up will be needed to monitor the descending aortic dissection.

  19. Clinical, manometric, and ultrasonographic results of pneumatic balloon dilatation vs. lateral internal sphincterotomy for chronic anal fissure: a prospective, randomized, controlled trial.

    Science.gov (United States)

    Renzi, Adolfo; Izzo, Domenico; Di Sarno, Giandomenico; Talento, Pasquale; Torelli, Francesco; Izzo, Giuseppe; Di Martino, Natale

    2008-01-01

    This prospective, randomized, controlled trial was designed to compare the clinical, functional, and morphologic results of pneumatic balloon dilatation with lateral internal sphincterotomy for the treatment of chronic anal fissure. All patients with symptomatic chronic anal fissure were randomly assigned to pneumatic balloon dilatation or lateral internal sphincterotomy and invited to complete a standardized questionnaire inquiring about their symptoms. Anal ultrasonography and anal manometry were performed before and six months after surgery. A proctologic examination was performed between the fifth and sixth postoperative weeks. Anal continence, scored by using a validated continence grading scale, was evaluated preoperatively at 1 and 6 weeks and at 12 and 24 months. Fifty-three patients, who satisfied selection criteria, were enrolled in the trial. Four patients (7.5 percent) were lost to follow-up. Twenty-four patients (11 males; mean age, 42 +/- 8.2 years) underwent pneumatic balloon dilatation and 25 patients (10 males; mean age, 44 +/- 7.3 years) underwent lateral internal sphincterotomy. Fissure-healing rates were 83.3 percent in the pneumatic balloon dilatation and 92 percent in the lateral internal sphincterotomy group. Recurrent anal fissure was observed in one patient (4 percent) after lateral internal sphincterotomy. At anal manometry, mean resting pressure decrements obtained after pneumatic balloon dilatation and lateral internal sphincterotomy were 30.5 and 34.3 percent, respectively. After pneumatic balloon dilatation, anal ultrasonography did not show any significant sphincter damage. At 24-month follow-up, the incidence of incontinence, irrespective of severity, was 0 percent in the pneumatic balloon dilatation group and 16 percent in the lateral internal sphincterotomy group (P < 0.0001). As lateral internal sphincterotomy, pneumatic balloon dilatation grants a high anal fissure-healing rate but with a statistically significant reduction in

  20. Aortic root replacement after previous surgical intervention on the aortic valve, aortic root, or ascending aorta.

    Science.gov (United States)

    Kirsch, E W Matthias; Radu, N Costin; Mekontso-Dessap, Armand; Hillion, Marie-Line; Loisance, Daniel

    2006-03-01

    Aortic root replacement after a previous operation on the aortic valve, aortic root, or ascending aorta remains a major challenge. Records of 56 consecutive patients (44 men; mean age, 56.4 +/- 13.6 years) undergoing reoperative aortic root replacement between June 1994 and June 2005 were reviewed retrospectively. Reoperation was performed 9.4 +/- 6.7 years after the last cardiac operation. Indications for reoperation were true aneurysm (n = 14 [25%]), false aneurysm (n = 10 [18%]), dissection or redissection (n = 9 [16%]), structural or nonstructural valve dysfunction (n = 10 [18%]), prosthetic valve-graft infection (n = 12 [21%]), and miscellaneous (n = 1 [2%]). Procedures performed were aortic root replacement (n = 47 [84%]), aortic root replacement plus mitral valve procedure (n = 5 [9%]), and aortic root replacement plus arch replacement (n = 4 [7%]). In 14 (25%) patients coronary artery bypass grafting had to be performed unexpectedly during the same procedure or immediately after the procedure to re-establish coronary perfusion. Hospital mortality reached 17.9% (n = 10). Multivariate logistic regression analysis revealed the need for unplanned perioperative coronary artery bypass grafting as the sole independent risk factor for hospital death (P = .005). Actuarial survival was 83.8% +/- 4.9% at 1 month, 73.0% +/- 6.3% at 1 year, and 65.7% +/- 9.0% at 5 years after the operation. One patient had recurrence of endocarditis 6.7 months after the operation and required repeated homograft aortic root replacement. Reoperative aortic root replacement remains associated with a high postoperative mortality. The need to perform unplanned coronary artery bypass grafting during reoperative aortic root replacement is a major risk factor for hospital death. The optimal technique for coronary reconstruction in this setting remains to be debated.

  1. Radiographic detection of artificial intra-bony defects in the edentulous area.

    Science.gov (United States)

    Van Assche, N; Jacobs, R; Coucke, W; van Steenberghe, D; Quirynen, M

    2009-03-01

    Since intra-bony pathologies might jeopardize implant outcome, their preoperative detection is crucial. In sixteen human cadaver bloc sections from upper and lower jaws, artificial defects with progressively increasing size (n=7) have been created. From each respective defect, analogue and digital intra-oral radiographs were taken, the latter processed via a periodontal filter and afterwards presented in black-white as well as in colour, resulting in three sets of 7 images per bloc section. Eight observers were asked to diagnosis an eventual defect on randomly presented radiographs, and at another occasion to rank each set based on the defect size. The clinicians were only able to identify a defect, when the junctional area was involved, except for bony pieces with a very homogeneous structure. For longitudinal evaluation of healing bone (e.g. after tooth extraction), colour digital images can be recommended. These observations indicate that intra-oral radiographs are not always reliable for the detection of any intra-bony defect.

  2. JACEE long duration balloon flights

    International Nuclear Information System (INIS)

    Burnett, T.; Iwai, J.; Lord, J.J.; Strausz, S.; Wilkes, R.J.; Dake, S.; Oda, H.; Miyamura, O.; Fuki, M.; Jones, W.V.; Gregory, J.; Hayashi, T.; Takahashi, U.; Tominaga, Y.; Wefel, J.P.; Fountain, W.; Derrickson, J.; Parnell, T.A.; Roberts, E.; Tabuki, T.; Watts, J.W.

    1989-01-01

    JACEE balloon-borne emulsion chamber detectors are used to observe the spectra and interactions of cosmic ray protons and nuclei in the energy range 1-100A TeV. Experience with long duration mid-latitude balloon flights and characteristics of the detector system that make it ideal for planned Antarctic balloon flights are discussed. 5 refs., 2 figs

  3. Fasting and meal-suppressed ghrelin levels before and after intragastric balloons and balloon-induced weight loss

    NARCIS (Netherlands)

    Mathus-Vliegen, E. M. H.; Eichenberger, R. I.

    2014-01-01

    Intragastric balloons may be an option for obese patients with weight loss failure. Its mode of action remains enigmatic. We hypothesised depressed fasting ghrelin concentrations and enhanced meal suppression of ghrelin secretion by the gastric fundus through balloon contact and balloon-induced

  4. Technologies developed by CNES balloon team

    Science.gov (United States)

    Sosa-Sesma, Sergio; Charbonnier, Jean-Marc; Deramecourt, Arnaud

    CNES balloon team develops and operates all the components of this kind of vehicle: it means envelope and gondola. This abstract will point out only developments done for envelope. Nowadays CNES offers to scientists four types of envelops that cover a large range of mission demands. These envelops are: 1. Zero pressure balloons: Size going from 3,000m3 to 600,000m3, this kind of envelop is ideal for short duration flights (a few hours) but if we use an intelligent management of ballast consumption and if we chose the best launch site, it is possible to perform medium duration flights (10/20 days depending on the ballast on board). Flight train mass starts at 50kg for small balloons and reach 1000kg for larger ones. Zero pressure balloons are inflated with helium gas. 2. Super pressure balloons: Diameter going from 2.5m to 12m, this kind of envelop is ideal for long duration flights (1 to 6 months). Flight train is inside the envelop for small balloons, it means 2.5 diameter meters which is usually called BPCL (Super pressure balloon for Earth boundary layer) and it is about 3kg of mass. Larger ones could lift external flight trains about 50kg of mass. Super pressure balloons are inflated with helium gas. 3. MIR balloons: Size going from 36,000m3 to 46,000m3. Ceiling is reach with helium gas but after three days helium is no longer present inside and lift force is produced by difference of temperature between air inside and air of atmosphere. Flight trains must not be over 50kg. 4. Aero Clipper balloons: A concept to correlate measurements done in oceans and in nearest layers of atmosphere simultaneously. Flight train is made by a "fish" that drags inside water and an atmospheric gondola few meters above "fish", both pushed by a balloon which profits of the wind force. Materials used for construction and assembling depend on balloon type; they are usually made of polyester or polyethylene. Thickness varies from 12 micrometers to 120 micrometers. Balloon assembling

  5. Abdominal aortic aneurysm surgery

    DEFF Research Database (Denmark)

    Gefke, K; Schroeder, T V; Thisted, B

    1994-01-01

    The goal of this study was to identify patients who need longer care in the ICU (more than 48 hours) following abdominal aortic aneurysm (AAA) surgery and to evaluate the influence of perioperative complications on short- and long-term survival and quality of life. AAA surgery was performed in 553...... patients, 51 (9%) of whom died within the first 48 hours. Of the 502 patients who survived for more than 48 hours, 109 required ICU therapy for more than 48 hours, whereas 393 patients were in the ICU for less than 48 hours. The incidence of preoperative risk factors was similar for the two groups...... combined failed to permit identification of patients in whom the perioperative survival rate was 0%. Even 20% of patients with multiorgan failure survived for 6 months. Of those patients who needed ICU therapy for more than 48 hours, 41 (38%) were alive at the end of 1988. In response to a questionnaire...

  6. Sequential transcatheter aortic valve implantation due to valve dislodgement - a Portico valve implanted over a CoreValve bioprosthesis.

    Science.gov (United States)

    Campante Teles, Rui; Costa, Cátia; Almeida, Manuel; Brito, João; Sondergaard, Lars; Neves, José P; Abecasis, João; M Gabriel, Henrique

    2017-03-01

    Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected for surgery due to advanced age and comorbidities. The patient underwent a first TAVI, with implantation of a Medtronic CoreValve ® , which became dislodged and migrated to the ascending aorta. Due to the previous balloon valvuloplasty, the patient's AS became moderate, and her symptoms improved. After several months, she required another intervention, performed with a St. Jude Portico ® repositionable self-expanding transcatheter aortic valve. There was a good clinical response that was maintained at one-year follow-up. The use of a self-expanding transcatheter bioprosthesis with repositioning features is a solution in cases of valve dislocation to avoid suboptimal positioning of a second implant, especially when the two valves have to be positioned overlapping or partially overlapping each other. Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Delayed Presentation of a Giant Ascending Aortic Aneurysm following Aortic Valve Replacement

    Directory of Open Access Journals (Sweden)

    Tugrul Göncü

    2009-01-01

    Full Text Available Giant ascending aortic aneurysm formation following aortic valve replacement is rare. A 28-year-old man who underwent aortic valve replacement with a prosthetic valve for aortic regurgitation secondary to congenital bicuspid aortic valve about 10 years ago was diagnosed with a giant ascending aortic aneurysm about 16 cm in diameter in follow-up. The aneurysm was resected leaving the functional old mechanical prosthesis in place and implanted a 34-mm Hemashield woven graft, associated with the left and right coronary artery button implantation. Histological findings of the aortic aneurysm wall showed cystic medial necrosis. The postoperative course was uneventful and postoperative examination demonstrated good surgical results.

  8. Two Tethered Balloon Systems

    Science.gov (United States)

    Youngbluth, Otto; Owens, Thomas L.; Storey, Richard W.

    1990-01-01

    Systems take meteorological measurements for variety of research projects. Report describes work done by NASA Langley Research Center in atmospheric research using tethered balloon systems composed of commercially available equipment. Two separate tethered balloon systems described in report have payloads and configurations tailored to requirements of specific projects. Each system capable of measuring atmospheric parameter or species in situ and then telemetering this data in real time to ground station. Meteorological data and concentration of ozone typically measured. Indicates instrumented tethered balloon systems have distinct advantages over other systems for gathering data on troposphere.

  9. The role of annular dimension and annuloplasty in tricuspid aortic valve repair.

    Science.gov (United States)

    de Kerchove, Laurent; Mastrobuoni, Stefano; Boodhwani, Munir; Astarci, Parla; Rubay, Jean; Poncelet, Alain; Vanoverschelde, Jean-Louis; Noirhomme, Philippe; El Khoury, Gebrine

    2016-02-01

    Valve sparing reimplantation can improve the durability of bicuspid aortic valve repair compared with subcommissural annuloplasty, especially in patients with a large basal ring. This study analyses the effect of basal ring size and annuloplasty on valve repair in the setting of a tricuspid aortic valve. From 1995 to 2013, 382 patients underwent elective tricuspid aortic valve repair. We included only those undergoing subcommissural annuloplasty, valve sparing reimplantation or no annuloplasty and in whom intraoperative transoesophageal echocardiography images were available for retrospective pre- and post-repair basal ring measurements (n = 323, subcommissural annuloplasty: 146, valve sparing reimplantation: 154, no annuloplasty: 23). In a subgroup of patients with available echocardiographic images, basal ring was retrospectively measured at the latest follow-up or prior to reoperation. subcommissural annuloplasty and valve sparing reimplantation were compared after matching for degree of aortic regurgitation and root size. All three groups differed significantly for most of preoperative characteristics. Hospital mortality was 0.9%. The median follow-up was 4.7 years. At 8 years, overall survival was 80 ± 5%. Freedom from reoperation and freedom from aortic regurgitation >1+ were 92 ± 5% and 71 ± 8%, respectively. In multivariate analysis, predictors of aortic regurgitation >1+ were left ventricular end-diastolic diameter (P = 0.003), cusp repair (P = 0.006), body surface area (P = 0.01) and subcommissural annuloplasty (P = 0.05). In subcommissural annuloplasty, freedom from aortic regurgitation >1+ was lower for patients with basal ring ≥28 mm compared with patients with basal ring 1+ was independent of basal ring size (P = 0.38). In matched comparison between subcommissural annuloplasty and valve sparing reimplantation, freedom from aortic regurgitation >1+ was not significantly different (P = 0.06), but in patients with basal ring ≥28 mm, valve sparing

  10. Recent Developments in Scientific Research Ballooning

    International Nuclear Information System (INIS)

    Jones, W. Vernon

    2007-01-01

    The National Aeronautics and Space Administration (NASA) Balloon Program is committed to meeting the need for extended duration scientific investigations by providing advanced balloon vehicles and support systems. A sea change in ballooning capability occurred with the inauguration of 8 - 20 day flights around Antarctica in the early 1990's. The attainment of 28-31 day flights and a record-breaking 42-day flight in, respectively, two and three circumnavigations of the continent has greatly increased the expectations of the scientific users. A new super-pressure balloon is currently under development for future flights of 60-100 days at any latitude, which would bring another sea change in scientific research ballooning

  11. Análise dos resultados imediatos da cirurgia de revascularização do miocárdio com e sem circulação extracorpórea Analysis of immediate results of on-pump versus off-pump coronary artery bypass grafting surgery

    Directory of Open Access Journals (Sweden)

    Marcos Antonio Cantero

    2012-03-01

    number of grafts per patient was 2.48 ± 0.43 in off-pump group and 2.90 ± 0.59 in on-pump group. In the off-pump group, 97.8% of patients received an internal thoracic artery graft, while on-pump group the percentage was 94.1% (P = 0.03. The rate of complete revascularization was similar in both groups. In off-pump group, the circumflex artery was revascularized in 48.9% and 68.2% in the onpump group (P = 0.01. Hospital mortality was 4.3% and 4.7%, respectively in the off-pump group in the on-pump group (P = 0.92. Off-pump group had fewer complications in relation to perioperative myocardial infarction (P = 0.02 and use of intra-aortic balloon pump (P = 0.01. CONCLUSION: The off-pump CABG is a safe procedure with hospital mortality similar to that observed in on-pump CABG, with lower rates of complications and less need for intra-aortic balloon.

  12. Pioneering Space Research with Balloons

    Science.gov (United States)

    Jones, W. V.

    NASA s Scientific Ballooning Planning Team has concluded that ballooning enables significant scientific discoveries while providing test beds for space instruments and training for young scientists Circumpolar flights around Antarctica have been spectacularly successful with fight durations up to 42 days Demand for participation in this Long-Duration Balloon LDB program a partnership with the U S National Science Foundation Office of Polar Programs is greater than the current capacity of two flights per campaign Given appropriate international agreements LDB flights in the Northern Hemisphere would be competitive with Antarctic flights and super-pressure balloons would allow comparable flights at any latitude The Balloon Planning Team made several recommendations for LDB flights provide a reliable funding source for sophisticated payloads extend the Antarctic capability to three flights per year and develop a comparable capability in the Arctic provide aircraft for intact-payload recovery develop a modest trajectory modification capability to enable longer flights and enhance super-pressure balloons to carry 1-ton payloads to 38 km Implementation of these recommendations would facilitate frequent access to near-space for cutting-edge research and technology development for a wide range of investigations

  13. Development of a New Coaxial Balloon Catheter System for Balloon-Occluded Retrograde Transvenous Obliteration (B-RTO)

    International Nuclear Information System (INIS)

    Tanoue, Shuichi; Kiyosue, Hiro; Matsumoto, Shunro; Hori, Yuzo; Okahara, Mika; Kashiwagi, Junji; Mori, Hiromu

    2006-01-01

    Purpose. To develop a new coaxial balloon catheter system and evaluate its clinical feasibility for balloon-occluded retrograde transvenous obliteration (B-RTO). Methods. A coaxial balloon catheter system was constructed with 9 Fr guiding balloon catheter and 5 Fr balloon catheter. A 5 Fr catheter has a high flexibility and can be coaxially inserted into the guiding catheter in advance. The catheter balloons are made of natural rubber and can be inflated to 2 cm (guiding) and 1 cm (5 Fr) maximum diameter. Between July 2003 and April 2005, 8 consecutive patients (6 men, 2 women; age range 33-72 years, mean age 55.5 years) underwent B-RTO using the balloon catheter system. Five percent ethanolamine oleate iopamidol (EOI) was used as sclerosing agent. The procedures, including maneuverability of the catheter, amount of injected sclerosing agent, necessity for coil embolization of collateral draining veins, and initial clinical results, were evaluated retrospectively. The occlusion rate was assessed by postcontrast CT within 2 weeks after B-RTO. Results. The balloon catheter could be advanced into the proximal potion of the gastrorenal shunt beyond the collateral draining vein in all cases. The amount of injected EOI ranged from 3 to 34 ml. Coil embolization of the collateral draining vein was required in 2 cases. Complete obliteration of gastric varices on initial follow-up CT was obtained in 7 cases. The remaining case required re-treatment that resulted in complete obstruction of the varices after the second B-RTO. No procedure-related complications were observed. Conclusion. B-RTO using the new coaxial balloon catheter is feasible. Gastric varices can be treated more simply by using this catheter system

  14. Preoperative Pulmonary Valvuloplasty in Tetralogy of Fallot with Right-To-Left Shunt

    Directory of Open Access Journals (Sweden)

    Baris Bugan

    2014-12-01

    Full Text Available Tetralogy of Fallot is the most common cyanotic congenital heart disease and characterized by right ventricular outflow tract obstruction, ventricular septal defect, overriding aorta, and right ventricular hypertrophy. Right ventricular outflow tract obstruction and ventricular septal defect are the major clinical components of the syndrome. Although most have undergone a corrective operation, an important minority of patients with tetralogy of Fallot have had a preoperative palliative procedure. Herein we reported a succesful palliative percutaneous balloon valvuloplasty of pulmonary stenosis at an 19-year-old female patient with tetralogy of Fallot who was considered as inoperable for corrective surgery due to right -to-left shunt.

  15. Transapical aortic valve implantation using a Symetis Acurate self-expandable bioprosthesis: initial outcomes of 10 patients.

    Science.gov (United States)

    Misterski, Marcin; Puślecki, Mateusz; Grygier, Marek; Olasińska-Wiśniewska, Anna; Lesiak, Maciej; Araszkiewicz, Aleksander; Perek, Barłomiej; Choręziak, Aneta; Lindner, Jacek; Komosa, Anna; Buczkowski, Piotr; Ligowski, Marcin; Katarzyński, Sławomir; Jemielity, Marek

    2017-06-01

    Transapical aortic valve implantation (TA-AVI) has been widely introduced for treatment of patients with severe aortic stenosis in the last decade. Here we report our first clinical experience with 10 patients using the second-generation transapical Symetis Acurate TA aortic valve designed for transapical implantation. To evaluate the results of transapical access in transcatheter aortic valve implantation (TAVI) among patients with unsuitable vascular access. All patients had been assessed by a local heart team and were disqualified from surgical aortic valve replacement (AVR) and the transfemoral TAVI approach. Mean age was 75.4 ±3.9 years (range: 68-80), with 20% being female. Logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) and STS (Society of Thoracic Surgeons) were 15.4 ±8.9% and 20.5 ±4.5%, respectively. All implantations were performed successfully in the intra-annular and subcoronary position. There were no conversions to surgical AVR. All patients survived 30-day follow-up. No strokes or transient ischemic attacks were reported. There was no need for pacemaker implantation and none of the patients demonstrated moderate or significant paravalvular leakage. The mean aortic gradients improved significantly from a baseline of 57.0 ±19.2 mm Hg to a 30-day value of 14.2 ±4.1 mm Hg. Our initial clinical results indicate satisfactory functionality in patients after trans-apical implantation of the Symetis Acurate aortic valve. The procedure of implantation seems to be straightforward and may be considered in patients in whom a transfemoral approach is not a good option.

  16. Complications of balloon packing in epistaxis

    NARCIS (Netherlands)

    Vermeeren, Lenka; Derks, Wynia; Fokkens, Wytske; Menger, Dirk Jan

    2015-01-01

    Although balloon packing appears to be efficient to control epistaxis, severe local complications can occur. We describe four patients with local lesions after balloon packing. Prolonged balloon packing can cause damage to nasal mucosa, septum and alar skin (nasal mucosa, the cartilaginous skeleton

  17. The bicuspid aortic valve and its relation to aortic dilation

    Directory of Open Access Journals (Sweden)

    Shi-Min Yuan

    2010-01-01

    Full Text Available BACKGROUND: A bicuspid aortic valve (BAV is a common congenital heart disease, which affects 1-2% of the population. However, the relationship between BAVs and aortic dilation has not been sufficiently elucidated. METHODS: A total of 241 BAV patients who were referred to this hospital for cardiac surgey over a 4.75-year period were included in this study. In addition to the clinical characteristics of the included patients, the morphological features of the aortic valve and aorta, the length of the left main coronary artery, and the laboratory findings (the coagulation and hematological parameters as well as the total cholesterol concentration were determined and compared with those of the tricuspid aortic valve (TAV patients. RESULTS: The BAV patients were younger than the TAV patients for a valve surgery in the last 3 months of the study period. The BAV patients were predominantly male. Most of the BAVs that were surgically treated were stenotic, regurgitant, or combined, and only 19 (7.88% were normally functioning valves. According to echocardiography or operative records, 148 (78.31% were type A, 31 (16.40% were type B, and 10 (5.29% were type C. The left main coronary artery was much shorter in the BAV patients than it was in the TAV patients. There was no significant difference between BAV and TAV patients in the total cholesterol concentrations; whereas differences were noted between patients receiving lipid-lowering therapy and those not receiving lipid-lowering therapy. The dimensions of the aortic root, sinotubular junction, and ascending aorta were beyond normal limits, while they were significantly smaller in the BAV patients than in the TAV patients. They were also much smaller in patients receiving statin therapy than those not receiving statin therapy in both groups. Moreover, the aortic dilation in the BAV group was found to be significantly associated with patient age. CONCLUSIONS: The BAV patients developed aortic wall and

  18. Comparison of arterial stiffness and microcirculatory changes following abdominal aortic aneurysm grafting.

    LENUS (Irish Health Repository)

    Moloney, M A

    2012-02-01

    BACKGOUND: Abdominal aortic aneurysm (AAA) surgery provides a unique opportunity to study the impact of arterial stiffness on central haemodynamics, reflected in augmentation index (AI). The aneurysmal aorta is significantly stiffer than undilated age-matched aorta. AIM: We investigated whether replacement of an aneurysmal aorta with a compliant graft would result in a decrease in AI, which would thus decrease myocardial workload parameters. METHODS: Patients undergoing elective open or endovascular AAA repair were assessed with applanation tonometry and laser fluximetry pre-operatively, immediately and long-term post-operatively. RESULTS: Replacement of a small segment of abnormal conduit vessel resulted in improvements in AI, demonstrating that arterial stiffness can be surgically manipulated. CONCLUSIONS: These results reflect a decreased myocardial workload post-aortic grafting. This decrease in AI is important from a risk factor management perspective, and arterial stiffness should become a further recognised and screened for risk factor in patients with known aneurysmal disease.

  19. Comparison of arterial stiffness and microcirculatory changes following abdominal aortic aneurysm grafting.

    LENUS (Irish Health Repository)

    Moloney, M A

    2010-11-11

    BACKGOUND: Abdominal aortic aneurysm (AAA) surgery provides a unique opportunity to study the impact of arterial stiffness on central haemodynamics, reflected in augmentation index (AI). The aneurysmal aorta is significantly stiffer than undilated age-matched aorta. AIM: We investigated whether replacement of an aneurysmal aorta with a compliant graft would result in a decrease in AI, which would thus decrease myocardial workload parameters. METHODS: Patients undergoing elective open or endovascular AAA repair were assessed with applanation tonometry and laser fluximetry pre-operatively, immediately and long-term post-operatively. RESULTS: Replacement of a small segment of abnormal conduit vessel resulted in improvements in AI, demonstrating that arterial stiffness can be surgically manipulated. CONCLUSIONS: These results reflect a decreased myocardial workload post-aortic grafting. This decrease in AI is important from a risk factor management perspective, and arterial stiffness should become a further recognised and screened for risk factor in patients with known aneurysmal disease.

  20. Aortic root reimplantation procedure: a new milestone in aortic valve-sparing operations

    Directory of Open Access Journals (Sweden)

    А. М. Чернявский

    2016-08-01

    Full Text Available Aim: Emphasis in this study was placed on clinical and functional assessment of a modified "Florida Sleeve" procedure during surgical correction of ascending aorta aneurysms with concomitant aortic insufficiency.Methods: 32 patients with an aneurysm of the ascending aorta and aortic insufficiency underwent a modified "Florida Sleeve" procedure. The average follow-up was 17 (0-60 months. The average age of patients was 57±13 (23-73 years 56±13 years.Results: The expected 4-year cumulative survival rate was 84.3%. Overall freedom from aortic insufficiency in the late period was 88.9%. Median aortic regurgitation was 1+ (1; 2. Long-term follow-up revealed no valve-associated complications.Conclusion: The aortic root reimplantation procedure enables optimal correction of the existing lesions of the aortic root without performing aortic valve replacement and demonstrates stable clinical and functional outcomes in the long-term period.Key words: aortic aneurysm; aortic valve; valve-sparing operations.FundingThe study had no sponsorship.Conflict of interestThe authors declare no conflict of interest.

  1. Acute Type II Aortic Dissection with Severe Aortic Regurgitation and Chronic Descending Aortic Dissection in Pregnant Patient with Marfan Syndrome

    OpenAIRE

    Lee, Seok-Soo; Jung, Tae-Eun; Lee, Dong Hyup

    2012-01-01

    Aortic dilatation and dissection are severe complications during pregnancy that can be fatal to both the mother and the fetus. The risks of these complications are especially high in pregnant patients with Marfan syndrome; however, incidents of descending aortic dissection are very rare. This case report involves a successful Bentall procedure for and recovery from a rare aortic dissection in a pregnant Marfan patient who developed acute type II aortic dissection with severe aortic regurgitat...

  2. Aortic valve replacement for aortic stenosis caused by alkaptonuria.

    Science.gov (United States)

    Hiroyoshi, Junko; Saito, Aya; Panthee, Nirmal; Imai, Yasushi; Kawashima, Dai; Motomura, Noboru; Ono, Minoru

    2013-03-01

    We report a case of aortic stenosis associated with ochronosis in a 70-year-old man who underwent biologic aortic valve replacement. Intraoperative findings included ochronosis of a severely calcified pigmented aortic valve along with pigmentation of the intima of the aorta. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Modelling Hot Air Balloons.

    Science.gov (United States)

    Brimicombe, M. W.

    1991-01-01

    A macroscopic way of modeling hot air balloons using a Newtonian approach is presented. Misleading examples using a car tire and the concept of hot air rising are discussed. Pressure gradient changes in the atmosphere are used to explain how hot air balloons work. (KR)

  4. Surgery for acute Type I aortic dissection without resection of supra-aortic entry sites leads to unfavourable aortic remodelling.

    Science.gov (United States)

    Heo, Woon; Song, Suk-Won; Lee, Kwang-Hun; Lee, Shin-Young; Kim, Tae-Hoon; Baek, Min-Young; Yoo, Kyung-Jong

    2018-01-29

    This study aimed to evaluate the impact of remnant re-entries in arch branches on postoperative change in the aortic arch and descending aortic diameters and the rate of major adverse aortic events. Between January 2010 and December 2016, 249 patients underwent surgery for acute Type I aortic dissection. Patients who underwent total arch replacement, had Marfan syndrome or had intramural haematoma were excluded. Seventy-two patients with predischarge and follow-up computed tomography scans were enrolled. Patients with and without re-entries in the arch branches after surgery were assigned to the supra-aortic entry (SAE, n = 21) and no supra-aortic entry (n = 51) groups, respectively. Diameters were measured at 7 levels: the innominate artery, left common carotid artery, left subclavian artery, 20 mm distal to the left subclavian artery, pulmonary artery bifurcation, coeliac axis and maximal diameter of the descending thoracic aorta. Growth rates at the levels of the pulmonary artery bifurcation and 20 mm distal to the left subclavian artery were significantly higher in the SAE group than in the no supra-aortic entry group. The rate of freedom from major adverse aortic events (annual growth >5 mm or maximal diameter of the descending thoracic aorta >50 mm) at 5 years was significantly higher in the no supra-aortic entry group than in the SAE group. Remnant SAE leads to unfavourable aortic remodelling after acute Type I aortic dissection repair. © The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  5. Solar research with stratospheric balloons

    Science.gov (United States)

    Vázquez, Manuel; Wittmann, Axel D.

    Balloons, driven by hot air or some gas lighter than air, were the first artificial machines able to lift payloads (including humans) from the ground. After some pioneering flights the study of the physical properties of the terrestrial atmosphere constituted the first scientific target. A bit later astronomers realized that the turbulence of the atmospheric layers above their ground-based telescopes deteriorated the image quality, and that balloons were an appropriate means to overcome, total or partially, this problem. Some of the most highly-resolved photographs and spectrograms of the sun during the 20th century were actually obtained by balloon-borne telescopes from the stratosphere. Some more recent projects of solar balloon astronomy will also be described.

  6. [Quality of life or life expectancy? Criteria and sources of information in the decision-making of patients undergoing aortic valve surgery].

    Science.gov (United States)

    Schmied, Wolfram; Barnick, Saskia; Heimann, Dierk; Schäfers, Hans-Joachim; Köllner, Volker

    2015-01-01

    Physicians are expected to involve patients adequately in the decision-making process prior to surgery. To this end, it is essential to have knowledge about the potential reasons for such a decision. In this study we investigated which information sources and decision criteria are important to patients prior to aortic valve surgery. A consecutive sample of 468 patients (70.1%m, aged 66.9±14.2 years) was examined 2 years after aortic valve replacement or reconstruction with a self-developed questionnaire. Preoperative discussion with a cardiologist or a cardiac surgeon was the information source patients used most frequently and felt to be the most helpful. The most important decision criterion was quality of life, followed by life expectancy and likelihood of reoperation. Two years postoperatively, 97.3% of the patients were satisfied with their decision. Preoperative counseling by a physician plays an essential role in the decision-making process prior to cardiac surgery. Patients want to be involved in decision-making, though they do not want to bear the full responsibility.

  7. Abdominal cavity balloon for preventing a patient's bleeding

    OpenAIRE

    Naber, E.E.H.; Rutten, H.J.T.; Jakimowicz, J.J.; Goossens, R.H.M.; Moes, C.C.M.; Buzink, S.N.

    2007-01-01

    The invention relates to an abdominal cavity balloon for preventing a haemorrhage in a patient's pelvic region, comprising an inflatable balloon, wherein the balloon is pro vided with a smooth surface and with a strip that is flex- urally stiff and formed to follow the balloon's shape for po sitioning the balloon.

  8. Acute Aortic Arch Perforation During Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis and a Gothic Aortic Arch

    DEFF Research Database (Denmark)

    Millan-Iturbe, Oscar; Sawaya, Fadi J.; Bieliauskas, Gintautas

    2017-01-01

    AS because of its unique anatomic features. This case report describes an acute aortic perforation during delivery of a transcatheter heart valve to treat a severe bicuspid AS with a “gothic aortic arch”; more careful evaluation of the preprocedural multislice computed tomographic scan would have unveiled...

  9. Calculating Payload for a Tethered Balloon System

    Science.gov (United States)

    Charles D. Tangren

    1980-01-01

    A graph method to calculate payload for a tethered balloon system, with the supporting helium lift and payload equations. is described. The balloon system is designed to collect emissions data during the convective-lift and no-convective-lift phases of a forest fire. A description of the balloon system and a list of factors affecting balloon selection are included....

  10. Intra-operative cone beam computed tomography can help avoid reinterventions and reduce CT follow up after infrarenal EVAR.

    Science.gov (United States)

    Törnqvist, P; Dias, N; Sonesson, B; Kristmundsson, T; Resch, T

    2015-04-01

    Re-interventions after endovascular abdominal aortic aneurysm repair (EVAR) are common and therefore a strict imaging follow up protocol is required. The purpose of this study was to evaluate whether cone beam computed tomography (CBCT) can detect intra-operative complications and to compare this with angiography and the 1 month CT follow up (computed tomography angiography [CTA]). Fifty-one patients (44 men) were enrolled in a prospective trial. Patients underwent completion angiography and CBCT during infrarenal EVAR. Contrast was used except when pre-operative renal insufficiency was present or if the maximum contrast dose threshold was reached. CBCT reconstruction included the top of the stent graft to the iliac bifurcation. Endoleaks, kinks, or compressions were recorded. CBCT was technically successful in all patients. Twelve endoleaks were detected on completion digital subtraction angiography (CA). CBCT detected 4/5 type 1 endoleaks, but only one type 2 endoleak. CTA identified eight type 2 endoleaks and one residual type I endoleak. Two cases of stent compression were seen on CA. CBCT revealed five stent compressions and one kink, which resulted in four intra-operative adjunctive manoeuvres. CTA identified all cases of kinks or compressions that were left untreated. Two of them were corrected later. No additional kinks/compressions were found on CTA. Groin closure consisted of 78 fascia sutures, nine cut downs, and 11 percutaneous sutures. Seven femoral artery pseudoaneurysms (<1 cm) were detected on CTA, but no intervention was needed. CA is better than CBCT in detecting and categorizing endoleaks but CBCT (with or without contrast) is better than CA for detection of kinks or stentgraft compression. CTA plus CBCT identified all significant complications noted on the 1 month follow up CTA. The use of intra-operative CA and CBCT could replace early CTA after standard EVAR thus reducing overall radiation and contrast use. Technical development might further

  11. Type A Dissection Involving Intimo-Intimal Intussusception Through the Aortic Valve.

    Science.gov (United States)

    Armour, Trygve; Armour, Sarah; Reddy, Pingle; Brinster, Derek

    2015-07-15

    The presentation, evaluation, management, and outcome of a case of type A circumferential dissection involving repeated retrograde intussusception of the intimal flap through the aortic valve is described in this case report. Fewer than 20 intimo-intimal intussusception cases have been described since the first report was published by Hufnagel in 1962, and outcomes have typically been poor because of delays in diagnosis. This case shows the potential for a positive outcome when the diagnosis of intimo-intimal intussusception is entertained and confirmed early in the course of treatment. Preoperative computed tomography and intraoperative transesophageal echocardiography were essential in diagnosis and operative planning.

  12. Neurodevelopmental Outcomes Following Regional Cerebral Perfusion with Neuromonitoring for Neonatal Aortic Arch Reconstruction

    Science.gov (United States)

    Andropoulos, Dean B.; Easley, R. Blaine; Brady, Ken; McKenzie, E. Dean; Heinle, Jeffrey S.; Dickerson, Heather A.; Shekerdemian, Lara S.; Meador, Marcie; Eisenman, Carol; Hunter, Jill V.; Turcich, Marie; Voigt, Robert G.; Fraser, Charles D.

    2013-01-01

    Background In this study we report magnetic resonance imaging (MRI) brain injury, and 12 month neurodevelopmental outcomes, when regional cerebral perfusion (RCP) is utilized for neonatal aortic arch reconstruction. Methods Fifty seven neonates receiving RCP during aortic arch reconstruction were enrolled in a prospective outcome study. RCP flows were determined by near-infrared spectroscopy and transcranial Doppler monitoring. Brain MRI were performed preoperatively and 7 days postoperatively. Bayley Scales of Infant Development III was performed at 12 months. Results Mean RCP time was 71 ± 28 minutes (range 5–121), mean flow 56.6 ± 10.6 ml/kg/min. New postoperative MRI brain injury was seen in 40% of patients. For 35 RCP patients at age 12 months, mean Bayley III composite standard scores were: Cognitive = 100.1 ± 14.6,(range 75–125); Language = 87.2 ± 15.0, (range 62–132); Motor = 87.9 ± 16.8, (range 58–121).Increasing duration of RCP was not associated with adverse neurodevelopmental outcomes. Conclusions Neonatal aortic arch repair with RCP utilizing a neuromonitoring strategy results in 12-month cognitive outcomes that are at reference population norms; language and motor outcomes are lower than the reference population norms by 0.8–0.9 standard deviation. This largest RCP group with neurodevelopmental outcomes published to date demonstrates that this technique is effective and safe in supporting the brain during neonatal aortic arch reconstruction. PMID:22766302

  13. Ballooning stable high beta tokamak equilibria

    International Nuclear Information System (INIS)

    Tuda, Takashi; Azumi, Masafumi; Kurita, Gen-ichi; Takizuka, Tomonori; Takeda, Tatsuoki

    1981-04-01

    The second stable regime of ballooning modes is numerically studied by using the two-dimensional tokamak transport code with the ballooning stability code. Using the simple FCT heating scheme, we find that the plasma can locally enter this second stable regime. And we obtained equilibria with fairly high beta (β -- 23%) stable against ballooning modes in a whole plasma region, by taking into account of finite thermal diffusion due to unstable ballooning modes. These results show that a tokamak fusion reactor can operate in a high beta state, which is economically favourable. (author)

  14. Balloon angioplasty of infrapopliteal artery in chronic lower limb ischemia with diabetes

    International Nuclear Information System (INIS)

    Wang Jianbo; Zhao Jungong; Zhu Yueqi; Li Minghua; Cheng Yingsheng; Cheng Yongde; Wang Jue

    2008-01-01

    Objective: To evaluate the technique, successful rate and perioperative complications together with the therapy and prevention of using PTA in treating diabetic patients with infrapopliteal arterial diseases. Methods: Angiographic and clinical data of 27 patients with diabetic lower limb ischemia treated by PTA from January 2006 to May 2007 were retrospectively reviewed. Rutherf0rd-Becker categories and ankle- brachial index(ABI)were evaluated before and after the treatment. The effects were compared between different lesion types (stenosis or occlusion)and between different ways of balloon technique. The complications were also analyzed, together with the primary, discussion of the therapy and prevention. Results: 24 patients showed improvement of ischemic symptoms, and 3 cases fell in failure. The intra-procedural main complications included acute thrombosis, vascular wall perforation, distal emboli resulting from plaque falling off and dissection. There were statistically significant differences between the effects of two type lesions and between different balloon methods. Conclusions: 1. The condition of lower limb arteries should be assessed carefully before operation. 2. PTA shows safe and good clinical result and ought to be recommended in treating diabetic patients with peripheral arterial diseases, especially the lower extremity ischemia. (authors)

  15. Scientific ballooning. Proceedings of the symposium on the scientific use of balloons and related technical problems, Innsbruck, Austria, May 29-June 10, 1978

    Energy Technology Data Exchange (ETDEWEB)

    Riedler, W

    1979-01-01

    The book includes works on operational and technical aspects of balloon launching I and II, cooperative balloon campaigns, and new developments in scientific use of balloons. The specific topics discussed are coordinated balloon and rocket measurements of stratospheric wind shears and turbulence, ballooning in Japan and India, magnetospheric processes investigated with data taken from balloon flights, and remote sensing of middle atmosphere winds from balloon platforms.

  16. In vitro analysis of balloon cuffing phenomenon: inherent biophysical properties of catheter material or mechanics of catheter balloon deflation?

    Science.gov (United States)

    Chung, Eric; So, Karina

    2012-06-01

    To investigates the different methods of balloon deflation, types of urinary catheters and exposure to urine media in catheter balloon cuffing. Bardex®, Bard-Lubri-Sil®, Argyle®, Releen® and Biocath® were tested in sterile and E.Coli inoculated urine at 0, 14 and 28 days. Catheter deflation was performed with active deflation; passive deflation; passive auto-deflation; and excision of the balloon inflow channel. Balloon cuffing was assessed objectively by running the deflated balloon over a plate of agar and subjectively by 3 independent observers. Bardex®, Argyle® and Biocath® showed greater degree of catheter balloon cuffing (p deflation was the worst method (p 0.05). Linear regression model analysis confirmed time as the most significant factor. The duration of catheters exposure, different deflation methods and types of catheters tested contributed significantly to catheter balloon cuffing (p < 0.01).

  17. Flight Qualification of the NASA's Super Pressure Balloon

    Science.gov (United States)

    Cathey, Henry; Said, Magdi; Fairbrother, Debora

    Designs of new balloons to support space science require a number of actual flights under various flight conditions to qualify them to as standard balloon flight offerings to the science community. Development of the new Super Pressure Balloon for the National Aeronautics and Space Administration’s Balloon Program Office has entailed employing new design, analysis, and production techniques to advance the state of the art. Some of these advances have been evolutionary steps and some have been revolutionary steps requiring a maturing understanding of the materials, designs, and manufacturing approaches. The NASA Super Pressure Balloon development end goal is to produce a flight vehicle that is qualified to carry a ton of science instrumentation, at an altitude greater than 33 km while maintaining a near constant pressure altitude for extended periods of up to 100 days, and at any latitude on the globe. The NASA’s Balloon Program Office has pursued this development in a carefully executed incremental approach by gradually increasing payload carrying capability and increasing balloon volume to reach these end goal. A very successful test flight of a ~200,700 m3 balloon was launch in late 2008 from Antarctica. This balloon flew for over 54 days at a constant altitude and circled the Antarctic continent almost three times. A larger balloon was flown from Antarctica in early 2011. This ~422,400 m3 flew at a constant altitude for 22 days making one circuit around Antarctica. Although the performance was nominal, the flight was terminated via command to recover high valued assets from the payload. The balloon designed to reach the program goals is a ~532,200 m3 pumpkin shaped Super Pressure Balloon. A test flight of this balloon was launched from the Swedish Space Corporation’s Esrange Balloon Launch Facilities near Kiruna, Sweden on 14 August, 2012. This flight was another success for this development program. Valuable information was gained from this short test

  18. Speckle tracking echocardiography derived 2-dimensional myocardial strain predicts left ventricular function and mass regression in aortic stenosis patients undergoing aortic valve replacement.

    Science.gov (United States)

    Staron, Adam; Bansal, Manish; Kalakoti, Piyush; Nakabo, Ayumi; Gasior, Zbigniew; Pysz, Piotr; Wita, Krystian; Jasinski, Marek; Sengupta, Partho P

    2013-04-01

    Regression of left ventricular (LV) mass in severe aortic stenosis (AS) following aortic valve replacement (AVR) reduces the potential risk of sudden death and congestive heart failure associated with LV hypertrophy. We investigated whether abnormalities of resting LV deformation in severe AS can predict the lack of regression of LV mass following AVR. Two-dimensional speckle tracking echocardiography (STE) was performed in a total of 100 subjects including 60 consecutive patients with severe AS having normal LV ejection fraction (EF > 50 %) and 40 controls. STE was performed preoperatively and at 4 months following AVR, including longitudinal strain assessed from the apical 4-chamber and 2-chamber views and the circumferential and rotational mechanics measured from the apical short axis view. In comparison with controls, the patients with AS showed a significantly lower LV longitudinal (p regression (>10 %) following AVR. In conclusion, STE can quantify the burden of myocardial dysfunction in patients with severe AS despite the presence of normal LV ejection fraction. Furthermore, resting abnormalities in circumferential strain at LV apex is related with a hemodynamic milieu associated with the lack of LV mass regression during short-term follow up after AVR.

  19. Esophageal achalasia : results of balloon dilation

    Energy Technology Data Exchange (ETDEWEB)

    Ki, Won Woo; Kang, Sung Gwon; Yoon, Kwon Ha; Kim, Nam Hyeon; Lee, Hyo Jeong; Yoon, Hyun Ki; Sung, Kyu Bo; Song, Ho Young [Ulsan Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-08-01

    To evaluate the clinical effectiveness of fluoroscopically guided balloon dilation in the treatment of esophageal achalasia. Under fluoroscopic guidance, 21 balloon dilation procedures were performed in 14 patients with achalasia. A balloon with a diameter of 20 mm was used for the initial attempt.If the patient tolerated this well, the procedure was repeated with a 10-20 mm balloon, placed alongside at the same session. If, however the patient complained of severe chest pain and/or a postprocedural esophagogram showed an improvement,the additional balloon was not used. For patients whose results were unsatisfactory, the dilation procedure was repeated at sessions three to seven days apart. Succesful dilation was achieved in 13 of 14 patients(92.9%), who needed a total of 20 sessions of balloon dilation, ranging from one to three sessions per patient(mean, 1.54 sessions). Esophageal rupture occured in one of 14 patients(7.1%) ; of the 13 patients who underwent a successful dilation procedure, 12(92.3%) were free of recurrent symptoms during the follow-up period of 1-56(mean, 18.5) months. The remaning patient(7.7%) had a recurrence seven months after dilation. Fluoroscopically guided balloon dilation seems to be safe and effective in the treatment of esophageal achalasia.

  20. Esophageal achalasia : results of balloon dilation

    International Nuclear Information System (INIS)

    Ki, Won Woo; Kang, Sung Gwon; Yoon, Kwon Ha; Kim, Nam Hyeon; Lee, Hyo Jeong; Yoon, Hyun Ki; Sung, Kyu Bo; Song, Ho Young

    1996-01-01

    To evaluate the clinical effectiveness of fluoroscopically guided balloon dilation in the treatment of esophageal achalasia. Under fluoroscopic guidance, 21 balloon dilation procedures were performed in 14 patients with achalasia. A balloon with a diameter of 20 mm was used for the initial attempt.If the patient tolerated this well, the procedure was repeated with a 10-20 mm balloon, placed alongside at the same session. If, however the patient complained of severe chest pain and/or a postprocedural esophagogram showed an improvement,the additional balloon was not used. For patients whose results were unsatisfactory, the dilation procedure was repeated at sessions three to seven days apart. Succesful dilation was achieved in 13 of 14 patients(92.9%), who needed a total of 20 sessions of balloon dilation, ranging from one to three sessions per patient(mean, 1.54 sessions). Esophageal rupture occured in one of 14 patients(7.1%) ; of the 13 patients who underwent a successful dilation procedure, 12(92.3%) were free of recurrent symptoms during the follow-up period of 1-56(mean, 18.5) months. The remaning patient(7.7%) had a recurrence seven months after dilation. Fluoroscopically guided balloon dilation seems to be safe and effective in the treatment of esophageal achalasia

  1. Endovascular Repair of Abdominal Aortic Aneurysms in the Presence of a Transplanted Kidney

    International Nuclear Information System (INIS)

    Silverberg, Daniel; Yalon, Tal; Halak, Moshe

    2015-01-01

    PurposeTo present our experience performing endovascular repair of abdominal aortic aneurysms in kidney transplanted patients.MethodsA retrospective review of all patients who underwent endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA) performed at our institution from 2007 to 2014. We identified all patients who had previously undergone a kidney transplant. Data collected included: comorbidities, preoperative imaging modalities, indication for surgery, stent graft configurations, pre- and postoperative renal function, perioperative complications, and survival rates.ResultsA total of 267 EVARs were performed. Six (2 %) had a transplanted kidney. Mean age was 74 (range, 64–82) years; five were males. Mean time from transplantation to EVAR was 7.5 (range, 2–12) years. Five underwent preoperative planning with noncontrast modalities only. Devices used included bifurcated (n = 3), aortouniiliac (n = 2), and tube (n = 1) stent grafts. Technical success was achieved in all patients. None experienced deterioration in renal function. Median follow-up was 39 (range, 6–51) months. Four patients were alive at the time of the study. Two patients expired during the period of follow-up from unrelated causes.ConclusionsEVAR is an effective modality for the management of AAAs in the coexistence of a transplanted kidney. It can be performed with minimal morbidity and mortality without harming the transplanted kidney. Special consideration should be given to device configuration to minimize damage to the renal graft

  2. Endovascular Repair of Abdominal Aortic Aneurysms in the Presence of a Transplanted Kidney

    Energy Technology Data Exchange (ETDEWEB)

    Silverberg, Daniel, E-mail: silverberg-d@msn.com; Yalon, Tal; Halak, Moshe [The Chaim Sheba Medical Center, The Department of Vascular Surgery (Israel)

    2015-08-15

    PurposeTo present our experience performing endovascular repair of abdominal aortic aneurysms in kidney transplanted patients.MethodsA retrospective review of all patients who underwent endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA) performed at our institution from 2007 to 2014. We identified all patients who had previously undergone a kidney transplant. Data collected included: comorbidities, preoperative imaging modalities, indication for surgery, stent graft configurations, pre- and postoperative renal function, perioperative complications, and survival rates.ResultsA total of 267 EVARs were performed. Six (2 %) had a transplanted kidney. Mean age was 74 (range, 64–82) years; five were males. Mean time from transplantation to EVAR was 7.5 (range, 2–12) years. Five underwent preoperative planning with noncontrast modalities only. Devices used included bifurcated (n = 3), aortouniiliac (n = 2), and tube (n = 1) stent grafts. Technical success was achieved in all patients. None experienced deterioration in renal function. Median follow-up was 39 (range, 6–51) months. Four patients were alive at the time of the study. Two patients expired during the period of follow-up from unrelated causes.ConclusionsEVAR is an effective modality for the management of AAAs in the coexistence of a transplanted kidney. It can be performed with minimal morbidity and mortality without harming the transplanted kidney. Special consideration should be given to device configuration to minimize damage to the renal graft.

  3. The use of transcatheter aortic valve replacement vs surgical aortic valve replacement for the treatment of aortic stenosis

    Directory of Open Access Journals (Sweden)

    Jensen HA

    2015-08-01

    Full Text Available Hanna A Jensen, Lillian L Tsai, Vinod H Thourani Division of Cardiothoracic Surgery, Joseph B Whitehead Department of Surgery, Structural Heart and Valve Center, Emory University School of Medicine, Atlanta, GA, USA Abstract: Severe aortic stenosis (AS is associated with considerable morbidity and mortality and is increasing in prevalence as the global population increases. Since AS primarily affects the elderly, many of these patients have comorbidities that make them poor candidates for the gold standard treatment for AS, surgical aortic valve replacement. Transcatheter aortic valve replacement has emerged as a novel technology for the management of AS in higher risk patients over the past decade. Randomized trials have established the safety and efficacy of transcatheter aortic valve replacement, and the medical community has rallied to identify the patients who are most suitable for this transformative treatment. This review focuses on outlining the key procedural differences, describing the unique challenges of both operations, and finally assessing and comparing outcomes both on a general level and in challenging patient subgroups. Keywords: aortic valve replacement, transcatheter aortic valve replacement, surgical aortic valve replacement 

  4. l-Arginine Pathway Metabolites Predict Need for Intra-operative Shunt During Carotid Endarterectomy

    DEFF Research Database (Denmark)

    Szabo, P; Lantos, J; Nagy, L

    2016-01-01

    lactate levels were increased during reperfusion (p = .02). The median pre-operative concentration of l-arginine was lower in patients requiring an intra-operative shunt than in patients without need of shunt (median: 30.3 μmol/L [interquartile range 24.4-34.4 μmol/L] vs. 57.6 μmol/L [interquartile range...

  5. Early Cosmic Ray Research with Balloons

    Energy Technology Data Exchange (ETDEWEB)

    Walter, Michael, E-mail: michael.walter@desy.de

    2013-06-15

    The discovery of cosmic rays by Victor Hess during a balloon flight in 1912 at an altitude of 5350 m would not have been possible without the more than one hundred years development of scientific ballooning. The discovery of hot air and hydrogen balloons and their first flights in Europe is shortly described. Scientific ballooning was mainly connected with activities of meteorologists. It was also the geologist and meteorologist Franz Linke, who probably observed first indications of a penetrating radiation whose intensity seemed to increase with the altitude. Karl Bergwitz and Albert Gockel were the first physicists studying the penetrating radiation during balloon flights. The main part of the article deals with the discovery of the extraterrestrial radiation by V. Hess and the confirmation by Werner Kolhörster.

  6. Early Cosmic Ray Research with Balloons

    Science.gov (United States)

    Walter, Michael

    2013-06-01

    The discovery of cosmic rays by Victor Hess during a balloon flight in 1912 at an altitude of 5350 m would not have been possible without the more than one hundred years development of scientific ballooning. The discovery of hot air and hydrogen balloons and their first flights in Europe is shortly described. Scientific ballooning was mainly connected with activities of meteorologists. It was also the geologist and meteorologist Franz Linke, who probably observed first indications of a penetrating radiation whose intensity seemed to increase with the altitude. Karl Bergwitz and Albert Gockel were the first physicists studying the penetrating radiation during balloon flights. The main part of the article deals with the discovery of the extraterrestrial radiation by V. Hess and the confirmation by Werner Kolhörster.

  7. Early Cosmic Ray Research with Balloons

    International Nuclear Information System (INIS)

    Walter, Michael

    2013-01-01

    The discovery of cosmic rays by Victor Hess during a balloon flight in 1912 at an altitude of 5350 m would not have been possible without the more than one hundred years development of scientific ballooning. The discovery of hot air and hydrogen balloons and their first flights in Europe is shortly described. Scientific ballooning was mainly connected with activities of meteorologists. It was also the geologist and meteorologist Franz Linke, who probably observed first indications of a penetrating radiation whose intensity seemed to increase with the altitude. Karl Bergwitz and Albert Gockel were the first physicists studying the penetrating radiation during balloon flights. The main part of the article deals with the discovery of the extraterrestrial radiation by V. Hess and the confirmation by Werner Kolhörster

  8. Altered aortic shape in bicuspid aortic valve relatives influences blood flow patterns.

    Science.gov (United States)

    Schnell, Susanne; Smith, Danielle A; Barker, Alex J; Entezari, Pegah; Honarmand, Amir R; Carr, Maria L; Malaisrie, S Chris; McCarthy, Patrick M; Collins, Jeremy; Carr, James C; Markl, Michael

    2016-11-01

    Bicuspid aortic valve (BAV) is known to exhibit familial inheritance and is associated with aortopathy and altered aortic haemodynamics. However, it remains unclear whether BAV-related aortopathy can be inherited independently of valve morphology. Four-dimensional flow magnetic resonance imaging for the in vivo assessment of thoracic aortic 3D blood flow was performed in 24 BAV relatives with trileaflet aortic valves (age = 40 ± 14 years) and 15 healthy controls (age = 37 ± 10 years). Data analysis included aortic dimensions, shape (round/gothic/cubic), and 3D blood flow characteristics (semi-quantitative vortex/helix grading and peak velocities). Cubic and gothic aortic shapes were markedly more prevalent in BAV relatives compared with controls (38 vs. 7%). Ascending aorta (AAo) vortex flow in BAV relatives was significantly increased compared with controls (grading = 1.5 ± 1.0 vs. 0.6 ± 0.9, P = 0.015). Aortic haemodynamics were influenced by aortic shape: peak velocities were reduced for gothic aortas vs. round aortas (P = 0.003); vortex flow was increased for cubic aortas in the AAo (P gothic aortas in the AAo and descending aorta (P = 0.003, P = 0.029). Logistic regression demonstrated significant associations of shape with severity of vortex flow in AAo (P < 0.001) and aortic arch (P = 0.016) in BAV relatives. BAV relatives expressed altered aortic shape and increased vortex flow despite the absence of valvular disease or aortic dilatation. These data suggest a heritable component of BAV-related aortopathy affecting aortic shape and aberrant blood flow, independent of valve morphology. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  9. Preoperative Thyroid Ultrasound Is Indicated in Patients Undergoing Parathyroidectomy for Primary Hyperparathyroidism

    Directory of Open Access Journals (Sweden)

    Cletus A. Arciero, Zita S. Shiue, Jeremy D. Gates, George E. Peoples, Alan P. B. Dackiw, Ralph P. Tufano, Steven K. Libutti, Martha A. Zeiger, Alexander Stojadinovic

    2012-01-01

    Full Text Available Background: Primary hyperaparathyroidism (pHPT is often accompanied by underlying thyroid pathology that can confound preoperative parathyroid localization studies and complicate intra-operative decision making. The aim of this study was to examine the utility of preoperative thyroid ultrasonography (US in patients prior to undergoing parathyroidectomy for pHPT.Methods: An Institutional Review Board approved prospective study was undertaken from January 2005 through July 2008. All patients with pHPT meeting inclusion criteria (n=94 underwent preoperative thyroid ultrasound in addition to standard 99mTc-sestamibi scintigraphy for parathyroid localization. Demographics, operative management and final pathology were examined in all cases.Results: Fifty-four of the 94 patients (57% were noted to have a thyroid nodule on preoperative US, of which 30 (56% underwent further examination with fine needle aspiration biopsy. Alteration of the operative plan attributable to underlying thyroid pathology occurred in 16 patients (17%, with patients undergoing either total thyroidectomy (n=9 or thyroid lobectomy (n=7. Thyroid cancer was noted in 33% of patients undergoing thyroid resection, and 6% of all patients with HPT.Conclusions: The routine utilization of preoperative thyroid ultrasound in patients prior to undergoing parathyroid surgery for pHPT is indicated. The added information from this non-invasive modality facilitates timely management of co-incidental, and sometimes malignant, thyroid pathology.

  10. Role of signal dose preoperative antibiotic in acute nonperforated appendicitics

    International Nuclear Information System (INIS)

    Malik, S.A.; Rasheed, M.; Abbasi, A.S.; Iqbal, R.A.; Mian, M.A.

    2013-01-01

    Objective: To determine the efficacy of a single dose of preoperative antibiotic in preventing post operative infective complications in patients undergoing appendicectomy for non perforated acute appendicitis. Study Design: Randomized controlled trials. Place and Duration of Study: Surgical unit I and II, department of General Surgery, Combined Military Hospital (CMH) Lahore from 1st June to 31st October 2010. Patients and Methods: Seventy patients with acute appendicitis scheduled for appendicectomy were included in the study and randomly divided into two groups of 35 each using random numbers table. Group A received single dose preoperative antibiotic and group B received three-dose regimens of cefuroxime. Postoperative infective complications were the primary endpoint. Results: The rate of postoperative wound infection was not statistically insignificantly different among the groups; (8.57%) group A and (5.71%) group B at 1st post operative week and (5.71%) group A and (5.71%) group B at 2nd post operative week. None of the patients from either group showed any signs of intra abdominal abscess formation. Conclusion: Single dose of preoperative antibiotics is adequate for prevention of postoperative infective complications in patients with non-perforated appendicitis undergoing open appendicectomy. (author)

  11. NASA balloon design and flight - Philosophy and criteria

    Science.gov (United States)

    Smith, I. S., Jr.

    1993-01-01

    The NASA philosophy and criteria for the design and flight of scientific balloons are set forth and discussed. The thickness of balloon films is standardized at 20.3 microns to isolate potential film problems, and design equations are given for specific balloon parameters. Expressions are given for: flight-stress index, total required thickness, cap length, load-tape rating, and venting-duct area. The balloon design criteria were used in the design of scientific balloons under NASA auspices since 1986, and the resulting designs are shown to be 95 percent effective. These results represent a significant increase in the effectiveness of the balloons and therefore indicate that the design criteria are valuable. The criteria are applicable to four balloon volume classes in combination with seven payload ranges.

  12. Measuring aortic pulse wave velocity using high-field cardiovascular magnetic resonance: comparison of techniques

    Directory of Open Access Journals (Sweden)

    Shaffer Jean M

    2010-05-01

    Full Text Available Abstract Background The assessment of arterial stiffness is increasingly used for evaluating patients with different cardiovascular diseases as the mechanical properties of major arteries are often altered. Aortic stiffness can be noninvasively estimated by measuring pulse wave velocity (PWV. Several methods have been proposed for measuring PWV using velocity-encoded cardiovascular magnetic resonance (CMR, including transit-time (TT, flow-area (QA, and cross-correlation (XC methods. However, assessment and comparison of these techniques at high field strength has not yet been performed. In this work, the TT, QA, and XC techniques were clinically tested at 3 Tesla and compared to each other. Methods Fifty cardiovascular patients and six volunteers were scanned to acquire the necessary images. The six volunteer scans were performed twice to test inter-scan reproducibility. Patient images were analyzed using the TT, XC, and QA methods to determine PWV. Two observers analyzed the images to determine inter-observer and intra-observer variabilities. The PWV measurements by the three methods were compared to each other to test inter-method variability. To illustrate the importance of PWV using CMR, the degree of aortic stiffness was assessed using PWV and related to LV dysfunction in five patients with diastolic heart failure patients and five matched volunteers. Results The inter-observer and intra-observer variability results showed no bias between the different techniques. The TT and XC results were more reproducible than the QA; the mean (SD inter-observer/intra-observer PWV differences were -0.12(1.3/-0.04(0.4 for TT, 0.2(1.3/0.09(0.9 for XC, and 0.6(1.6/0.2(1.4 m/s for QA methods, respectively. The correlation coefficients (r for the inter-observer/intra-observer comparisons were 0.94/0.99, 0.88/0.94, and 0.83/0.92 for the TT, XC, and QA methods, respectively. The inter-scan reproducibility results showed low variability between the repeated

  13. Total aortic arch replacement with the frozen elephant trunk technique: 10-year follow-up single-centre experience.

    Science.gov (United States)

    Ius, Fabio; Fleissner, Felix; Pichlmaier, Maximilian; Karck, Matthias; Martens, Andreas; Haverich, Axel; Shrestha, Malakh

    2013-11-01

    Since August 2001, the frozen elephant trunk (FET) technique has been used at our institution to treat degenerative or dissecting aneurysms involving the aortic arch and descending aorta as a potential 'single-stage' procedure. The aim of this study was to review our FET experience and to present the 10-year results. Between August 2001 and January 2012, 131 patients underwent FET implant with three different prostheses: the custom-made Chavan-Haverich (n = 66), the Jotec E-vita (n = 30) and the Vascutek Thoraflex (n = 35) prostheses. Concomitant procedures included aortic valve-sparing operations (David, n = 17) and aortic root replacement (Bentall, n = 25). Patient records and the first postoperative and last available computer tomography (CT) were retrospectively reviewed. Incidence of rethoracotomy for bleeding, stroke, spinal cord injury, prolonged ventilatory support (>96 h) and acute renal failure requiring dialysis were 18, 11, 1, 41 and 16%, respectively. In-hospital mortality was 15%. The mean follow-up was 42 ± 37 (range 1-134 months). At 1, 5 and 10 years, survivals were 82 ± 3, 72 ± 5 and 58 ± 8%, respectively. Freedoms from distal aortic operation were 81 ± 4, 67 ± 5 and 43 ± 13%, respectively. Thirty-six patients underwent 40 distal aortic operations, either open surgical (n = 22, 55%) or endovascular (n = 18, 45%). Chronic aortic dissection was identified as an independent risk factor for distal aortic operation (odds ratio = 3.8; 95% confidence interval 1.5-9.3; P = 0.004). At last CT control, false-lumen thrombosis rates up to 93% were achieved around the stent graft. An FET concept adds to the armament of the surgeon in the treatment of complex and diverse aortic arch pathologies. The preoperative patient risk profile explains the postoperative morbidity and in-hospital mortality. The FET can potentially be still a 'one-stage' procedure in selected patients. However, the extension of FET to patients with extensive aortic aneurysms has led

  14. Long-Term Risk for Aortic Complications After Aortic Valve Replacement in Patients With Bicuspid Aortic Valve Versus Marfan Syndrome.

    Science.gov (United States)

    Itagaki, Shinobu; Chikwe, Joanna P; Chiang, Yuting P; Egorova, Natalia N; Adams, David H

    2015-06-09

    Bicuspid aortic valves are associated with valve dysfunction, ascending aortic aneurysm and dissection. Management of the ascending aorta at the time of aortic valve replacement (AVR) in these patients is controversial and has been extrapolated from experience with Marfan syndrome, despite the absence of comparative long-term outcome data. This study sought to assess whether the natural history of thoracic aortopathy after AVR in patients with bicuspid aortic valve disease is substantially different from that seen in patients with Marfan syndrome. In this retrospective comparison, outcomes of 13,205 adults (2,079 with bicuspid aortic valves, 73 with Marfan syndrome, and 11,053 control patients with acquired aortic valve disease) who underwent primary AVR without replacement of the ascending aorta in New York State between 1995 and 2010 were compared. The median follow-up time was 6.6 years. The long-term incidence of thoracic aortic dissection was significantly higher in patients with Marfan syndrome (5.5 ± 2.7%) compared with those with bicuspid valves (0.55 ± 0.21%) and control group patients (0.41 ± 0.08%, p Marfan syndrome (10.8 ± 4.4%) compared with those with bicuspid valves (4.8 ± 0.8%) and control group patients (1.4 ± 0.2%) (p Marfan syndrome were significantly more likely to undergo thoracic aortic surgery in late follow-up (10.4 ± 4.3%) compared with those with bicuspid valves (2.5 ± 0.6%) and control group patients (0.50 ± 0.09%) (p Marfan syndrome compared with those with bicuspid aortic valves confirm that operative management of patients with bicuspid aortic valves should not be extrapolated from Marfan syndrome and support discrete treatment algorithms for these different clinical entities. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  15. Preoperative renin-angiotensin system inhibitors protect renal function in aging patients undergoing cardiac surgery.

    Science.gov (United States)

    Barodka, Viachaslau; Silvestry, Scott; Zhao, Ning; Jiao, Xiangyin; Whellan, David J; Diehl, James; Sun, Jian-Zhong

    2011-05-15

    Renal failure (RF) represents a major postoperative complication for elderly patients undergoing cardiac surgery. This observational cohort study examines effects of preoperative use of renin-angiotensin system (RAS) inhibitors on postoperative renal failure in aging patients undergoing cardiac surgery. We retrospectively analyzed a cohort of 1287 patients who underwent cardiac surgery at this institution (2003-2007). The patients included were ≥65 years old, scheduled for elective cardiac surgery, and without preexisting RF (defined by the criteria of the Society of Thoracic Surgeons as described in Method). Of all patients evaluated, 346 patients met the inclusion criteria and were divided into two groups: using (n = 122) or not using (n = 224) preoperative RAS inhibitors. A comparison of the two groups showed no significant differences in baseline parameters, including creatinine clearance, body mass index, history of diabetes and smoking, preoperative medicines (except that more patients with RAS inhibitors had a history of hypertension or congestive heart failure, fewer RAS inhibitor patients had chronic lung disease), in intraoperative perfusion and aortic cross-clamp time, and in postoperative complications and 30-d mortality. Multivariate logistic regression analysis demonstrated, however, that preoperative RAS inhibitors significantly and independently reduced the incidence of postoperative RF in the patients undergoing cardiac surgery compared with those not taking RAS inhibitors: 1.6% versus 7.6%, yielding an odds ratio of 0.19 (95 % CI 0.04-0.84, P = 0.029). Preoperative RAS inhibitors may have significant renoprotective effects for aging patients undergoing elective cardiac surgery. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Efficacy and surgical procedures of preoperative splenic artery embolization for laparoscopic splenectomy of a massive splenomegaly: A case report

    Directory of Open Access Journals (Sweden)

    Toshikatsu Nitta

    2015-01-01

    Full Text Available Here, we describe the case of a 58-year-old woman diagnosed with massive splenomegaly with a malignant lymphoma that had a maximum diameter of 24 cm. Splenectomy was indicated because of thrombocytopenia and abdominal distention. Therefore, a balloon catheter was inserted preoperatively through the splenic artery for embolization and continuous infusion to reduce the spleen volume. It enabled easy handling of the spleen and minimized bleeding. The volume of the spleen was estimated at 1896 g through the skin incision, as measured by volumetric computed tomography; thus, laparoscopy seemed difficult. However, the surgery was successfully performed only with laparoscopic surgery, and the volume of the resected spleen was 1020 g. This preoperative preparation is an effective alternative to laparoscopic removal of a huge splenomegaly.

  17. Percutaneous treatment of extrahepatic bile duct stones assisted by balloon sphincteroplasty and occlusion balloon

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yong Sung; Kim, Ji Hyung; Choi, Young Woo; Lee, Tae Hee; Hwang, Cheol Mog; Cho, Young Jun; Kim, Keum Won [Konyang University Hospital, Daejeon (Korea, Republic of)

    2005-12-15

    To describe the technical feasibility and usefulness of extrahepatic biliary stone removal by balloon sphincteroplasty and occlusion balloon pushing. Fifteen patients with extrahepatic bile duct stones were included in this study. Endoscopic stone removal was not successful in 13 patients, and two patients refused the procedure due to endoscopy phobia. At first, all patients underwent percutaneous transhepatic biliary drainage (PTBD). A few days later, through the PTBD route, balloon assisted dilatation for common bile duct (CBD) sphincter was performed, and then the stones were pushed into the duodenum using an 11.5 mm occlusion balloon. Success rate, reason for failure, and complications associated with the procedure were evaluated. Eight patients had one stone, five patients had two stones, and two patients had more than five stones. The procedure was successful in 13 patients (13/15). In 12 of the patients, all stones were removed in the first trial. In one patients, residual stones were discovered on follow-up cholangiography, and were subsequently removed in the second trial. Technical failure occurred in two patients. Both of these patients had severely dilated CBD and multiple stones with various sizes. Ten patients complained of pain in the right upper quadrant and epigastrium of the abdomen immediately following the procedure, but there were no significant procedure-related complications such as bleeding or pancreatitis. Percutaneous extrahepatic biliary stone removal by balloon sphincteroplasty and subsequent stone pushing with occlusion balloon is an effective, safe, and technically feasible procedure which can be used as an alternative method in patients when endoscopic extrahepatic biliary stone removal was not successful.

  18. Percutaneous treatment of extrahepatic bile duct stones assisted by balloon sphincteroplasty and occlusion balloon

    International Nuclear Information System (INIS)

    Park, Yong Sung; Kim, Ji Hyung; Choi, Young Woo; Lee, Tae Hee; Hwang, Cheol Mog; Cho, Young Jun; Kim, Keum Won

    2005-01-01

    To describe the technical feasibility and usefulness of extrahepatic biliary stone removal by balloon sphincteroplasty and occlusion balloon pushing. Fifteen patients with extrahepatic bile duct stones were included in this study. Endoscopic stone removal was not successful in 13 patients, and two patients refused the procedure due to endoscopy phobia. At first, all patients underwent percutaneous transhepatic biliary drainage (PTBD). A few days later, through the PTBD route, balloon assisted dilatation for common bile duct (CBD) sphincter was performed, and then the stones were pushed into the duodenum using an 11.5 mm occlusion balloon. Success rate, reason for failure, and complications associated with the procedure were evaluated. Eight patients had one stone, five patients had two stones, and two patients had more than five stones. The procedure was successful in 13 patients (13/15). In 12 of the patients, all stones were removed in the first trial. In one patients, residual stones were discovered on follow-up cholangiography, and were subsequently removed in the second trial. Technical failure occurred in two patients. Both of these patients had severely dilated CBD and multiple stones with various sizes. Ten patients complained of pain in the right upper quadrant and epigastrium of the abdomen immediately following the procedure, but there were no significant procedure-related complications such as bleeding or pancreatitis. Percutaneous extrahepatic biliary stone removal by balloon sphincteroplasty and subsequent stone pushing with occlusion balloon is an effective, safe, and technically feasible procedure which can be used as an alternative method in patients when endoscopic extrahepatic biliary stone removal was not successful

  19. Gondola development for CNES stratospheric balloons

    Science.gov (United States)

    Vargas, A.; Audoubert, J.; Cau, M.; Evrard, J.; Verdier, N.

    The CNES has been supporting scientific ballooning since its establishment in 1962. The two main parts of the balloon system or aerostat are the balloon itself and the flight train, comprising the house-keeping gondola, for the control of balloon flight (localization and operational telemetry & telecommand - TM/TC), and the scientific gondola with its dedicated telecommunication system. For zero pressure balloon, the development of new TM/TC system for the housekeeping and science data transmission are going on from 1999. The main concepts are : - for balloon house-keeping and low rate scientific telemetry, the ELITE system, which is based on single I2C bus standardizing communication between the different components of the system : trajectography, balloon control, power supply, scientific TM/TC, .... In this concept, Radio Frequency links are developed between the house keeping gondola and the components of the aerostat (balloon valve, ballast machine, balloon gas temperature measurements, ...). The main objectives are to simplify the flight train preparation in term of gondola testing before flight, and also by reducing the number of long electrical cables integrated in the balloon and the flight train; - for high rate scientific telemetry, the use of functional interconnection Internet Protocol (IP) in interface with the Radio Frequency link. The main idea is to use off-the-shelf IP hardware products (routers, industrial PC, ...) and IP software (Telnet, FTP, Web-HTTP, ...) to reduce the development costs; - for safety increase, the adding, in the flight train, of a totally independent house keeping gondola based on the satellite Inmarsat M and Iridium telecommunication systems, which permits to get real time communications between the on-board data mobile and the ground station, reduced to a PC computer with modem connected to the phone network. These GEO and LEO telecommunication systems give also the capability to operate balloon flights over longer distance

  20. Transcatheter aortic valve replacement in patients with severe aortic stenosis who are at high risk for surgical complications: summary assessment of the California Technology Assessment Forum.

    Science.gov (United States)

    Tice, Jeffrey A; Sellke, Frank W; Schaff, Hartzell V

    2014-08-01

    The California Technology Assessment Forum is dedicated to assessment and public reporting of syntheses of available data on medical technologies. In this assessment, transcatheter aortic valve replacement (TAVR) was evaluated for patients with severe aortic stenosis (AS) who are at high risk for complications. In this assessment, 5 criteria were used: Regulatory approval, sufficient scientific evidence to allow conclusions on effectiveness, evidence that the technology improves net health outcomes, evidence that the technology is as beneficial as established methods, and availability of the technology outside investigational settings. In this assessment, all 5 criteria were judged to have been met. The primary benefit of TAVR is the ability to treat AS in patients who would otherwise be ineligible for surgical aortic valve replacement. It may also be useful for patients at high surgical risk by potentially reducing periprocedural complications and avoiding the morbidity and recovery from undergoing heart surgery. Potential harms include the need for conversion to an open procedure, perioperative death, myocardial infarction, stroke, bleeding, valve embolization, aortic regurgitation, heart block that requires a permanent pacemaker, renal failure, pulmonary failure, and major vascular complications such as cardiac perforation or arterial dissection. Potential long-term harms include death, stroke, valve failure or clotting, and endocarditis. As highlighted at the February 2012 California Technology Assessment Forum meeting, the dispersion of this technology to new centers across the United States must proceed with careful thought given to training and proctoring multidisciplinary teams to become new centers of excellence. TAVR is a potentially lifesaving procedure that may improve quality of life for patients at high risk for surgical AVR. However, attention needs to be paid to appropriate patient selection, their preoperative evaluation, surgical techniques, and

  1. A phase I trial of pre-operative radiotherapy for prostate cancer: Clinical and translational studies

    International Nuclear Information System (INIS)

    Supiot, Stephane; Shubbar, Shubber; Fleshner, Neil; Warde, Padraig; Hersey, Karen; Wallace, Kris; Cole, Heather; Sweet, Joan; Tsihlias, John; Jewett, Michael A.S.; Klotz, Laurence; Bristow, Robert G.

    2008-01-01

    Background and purpose: Selected patients undergoing radical prostatectomy for localized prostate cancer can be at high-risk for pT3 disease and require subsequent radiotherapy. In a phase I trial, we investigated the feasibility of pre-operative radiotherapy for this patient subset. Materials and methods: Eligibility criteria were: T1/T2N0M0 tumors plus (i) Gleason ≥ 7, PSA > 10 ng/ml and 15 ng/ml and less WAF associated with reduced cell proliferation. Conclusion: Intra-operative morbidity is low following short-course, pre-operative radiotherapy. A phase II trial is planned to fully document biochemical response with this combined-modality approach

  2. A comparison of radiological and historical findings in osteosarcomas following pre-operative chemotherapy

    International Nuclear Information System (INIS)

    Sommer, H.J.; Riebel, T.; Winkler, K.; Heise, U.; Delling, G.; Hamburg Univ.; Hamburg Univ.

    1985-01-01

    Since the introduction of pre-operative chemotherapy, osteosarcomas have shown a more favourable prognosis. Reaction of the tumour due to chemotherapy is judged pre-operative primarily by radiology (plain films, angiography, CT, scintigraphy). There is little evidence concerning the radiological appearances after pre-operative chemotherapy and morphological changes, particularly in respect of tumour regression. Specific radiological changes were therefore compared with pathological findings following chemotherapy and operation in 17 patients with osteosarcomas. Tumours were examined which showed radiological evidence of intra- and extra-osseous sclerosis or lysis and which still were classified as vital tumour tissue. Tumour planes were reconstructed from large histological sections of the operative specimen and compared with the radiological appearances. Sclerosis was found to be due to reactive new bone formation or to mineralisation of the osteosarcomatous tissue. Lysis correlated with persistent vital tumour, or in connective tissue. Nine out of ten cases, regarded as vital on radiological evidence, showed vital tumour cells on histological section. Lyses and scleroses were not reliable indications of the pre-operative state of the osteosarcoma following chemotherapy. On the other hand, combined qualitative radiological criteria for assesing tumour vitality, proved to be helpful. (orig.) [de

  3. Longitudinal Hemodynamics of Transcatheter and Surgical Aortic Valves in the PARTNER Trial.

    Science.gov (United States)

    Douglas, Pamela S; Leon, Martin B; Mack, Michael J; Svensson, Lars G; Webb, John G; Hahn, Rebecca T; Pibarot, Philippe; Weissman, Neil J; Miller, D Craig; Kapadia, Samir; Herrmann, Howard C; Kodali, Susheel K; Makkar, Raj R; Thourani, Vinod H; Lerakis, Stamatios; Lowry, Ashley M; Rajeswaran, Jeevanantham; Finn, Matthew T; Alu, Maria C; Smith, Craig R; Blackstone, Eugene H

    2017-11-01

    Use of transcatheter aortic valve replacement (TAVR) for severe aortic stenosis is growing rapidly. However, to our knowledge, the durability of these prostheses is incompletely defined. To determine the midterm hemodynamic performance of balloon-expandable transcatheter heart valves. In this study, we analyzed core laboratory-generated data from echocardiograms of all patients enrolled in the Placement of Aortic Transcatheter Valves (PARTNER) 1 Trial with successful TAVR or surgical AVR (SAVR) obtained preimplantation and at 7 days, 1 and 6 months, and 1, 2, 3, 4, and 5 years postimplantation. Patients from continued access observational studies were included for comparison. Successful implantation after randomization to TAVR vs SAVR (PARTNER 1A; TAVR, n = 321; SAVR, n = 313), TAVR vs medical treatment (PARTNER 1B; TAVR, n = 165), and continued access (TAVR, n = 1996). Five-year echocardiogram data were available for 424 patients after TAVR and 49 after SAVR. Death or reintervention for aortic valve structural indications, measured using aortic valve mean gradient, effective orifice area, Doppler velocity index, and evidence of hemodynamic deterioration by reintervention, adverse hemodynamics, or transvalvular regurgitation. Of 2795 included patients, the mean (SD) age was 84.5 (7.1) years, and 1313 (47.0%) were female. Population hemodynamic trends derived from nonlinear mixed-effects models showed small early favorable changes in the first few months post-TAVR, with a decrease of -2.9 mm Hg in aortic valve mean gradient, an increase of 0.028 in Doppler velocity index, and an increase of 0.09 cm2 in effective orifice area. There was relative stability at a median follow-up of 3.1 (maximum, 5) years. Moderate/severe transvalvular regurgitation was noted in 89 patients (3.7%) after TAVR and increased over time. Patients with SAVR showed no significant changes. In TAVR, death/reintervention was associated with lower ejection fraction, stroke volume

  4. Simultaneous stent expansion/balloon deflation technique to salvage failed balloon remodeling.

    Science.gov (United States)

    Ladner, Travis R; He, Lucy; Davis, Brandon J; Froehler, Michael T; Mocco, J

    2016-04-01

    Herniation, with possible embolization, of coils into the parent vessel following aneurysm coiling remains a frequent challenge. For this reason, balloon or stent assisted embolization remains an important technique. Despite the use of balloon remodeling, there are occasions where, on deflation of the balloon, some coils, or even the entire coil mass, may migrate. We report the successful use of a simultaneous adjacent stent deployment bailout technique in order to salvage coil prolapse during balloon remodeling in three patients. Case No 1 was a wide neck left internal carotid artery bifurcation aneurysm, measuring 9 mm×7.9 mm×6 mm with a 5 mm neck. Case No 2 was a complex left superior hypophyseal artery aneurysm, measuring 5.3 mm×4 mm×5 mm with a 2.9 mm neck. Case No 3 was a ruptured right posterior communicating artery aneurysm, measuring 4 mm×4 mm×4.5 mm with a 4 mm neck. This technique successfully returned the prolapsed coil mass into the aneurysm sac in all cases without procedural complications. The closed cell design of the Enterprise VRD (Codman and Shurtleff Inc, Raynham, Massachusetts, USA) makes it ideal for this bailout technique, by allowing the use of an 0.021 inch delivery catheter (necessary for simultaneous access) and by avoiding the possibility of an open cell strut getting caught on the deflated balloon. We hope this technique will prove useful to readers who may find themselves in a similar predicament. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  5. Melatonin reduces cardiac morbidity and markers of myocardial ischemia after elective abdominal aortic aneurism repair

    DEFF Research Database (Denmark)

    Gögenür, Ismail; Kücükakin, Bülent; Panduro Jensen, Leif

    2014-01-01

    The aim was to examine the effect of perioperative melatonin treatment on clinical cardiac morbidity and markers of myocardial ischemia in patients undergoing elective surgery for abdominal aortic aneurism. Reperfusion injury results in increased cardiac morbidity in patients undergoing surgery...... for abdominal aortic aneurisms (AAA). A randomized, placebo-controlled, clinical trial including patients undergoing surgery for AAA was performed. The patients received by infusion over a 2-hr period either, 50 mg melatonin or placebo intra-operatively, and 10 mg melatonin or placebo orally, the first three...... by Holter monitoring. A total of 26 patients received melatonin, while 24 received placebo. A significant reduction in cardiac morbidity was seen in the melatonin-treated patients compared with those given placebo [4% versus 29% (P = 0.02)]. Five patients (19%) who received melatonin had increased Tp...

  6. Are drug-coated balloons cost effective for femoropopliteal occlusive disease? A comparison of bare metal stents and uncoated balloons.

    Science.gov (United States)

    Poder, Thomas G; Fisette, Jean-François

    2016-07-01

    To perform a cost-effectiveness analysis to help hospital decision-makers with regard to the use of drug-coated balloons compared with bare metal stents and uncoated balloons for femoropopliteal occlusive disease. Clinical outcomes were extracted from the results of meta-analyses already published, and cost units are those used in the Quebec healthcare network. The literature review was limited to the last four years to obtain the most recent data. The cost-effectiveness analysis was based on a 2-year perspective, and risk factors of reintervention were considered. The cost-effectiveness analysis indicated that drug-coated balloons were generally more efficient than bare metal stents, particularly for patients with higher risk of reintervention (up to CAD$1686 per patient TASC II C or D). Compared with uncoated balloons, results indicated that drug-coated balloons were more efficient if the reintervention rate associated with uncoated balloons is very high and for patients with higher risk of reintervention (up to CAD$3301 per patient). The higher a patient's risk of reintervention, the higher the savings associated with the use of a drug-coated balloon will be. For patients at lower risk, the uncoated balloon strategy is still recommended as a first choice for endovascular intervention.

  7. Anderson localization and ballooning eigenfunctions

    International Nuclear Information System (INIS)

    Dewar, R.L.; Cuthbert, P.

    1999-01-01

    In solving the ballooning eigenvalue for a low-aspect-ratio stellarator equilibrium it is found that the quasiperiodic behaviour of the equilibrium quantities along a typical magnetic field line can lead to localization of the ballooning eigenfunction (Anderson localization) even in the limit of zero shear. This localization leads to strong field-line dependence of the ballooning eigenvalue, with different branches attaining their maximum growth rates on different field lines. A method is presented of estimating the field-line dependence of various eigenvalue branches by using toroidal and poloidal symmetry operations on the shear-free ballooning equation to generate an approximate set of eigenfunctions. These zero-shear predictions are compared with accurate numerical solutions for the H-1 Heliac and are shown to give a qualitatively correct picture, but finite shear corrections will be needed to give quantitative predictions

  8. Comparison of results of Bakri balloon tamponade and caesarean hysterectomy in management of placenta accreta and increta: a retrospective study.

    Science.gov (United States)

    Pala, Şehmus; Atilgan, Remzi; Başpınar, Melike; Kavak, Ebru Çelik; Yavuzkır, Şeyda; Akyol, Alparslan; Kavak, Burçin

    2018-02-01

    The aim of this study was to compare the postoperative results of the patients who were treated with Bakri balloon tamponade or hysterectomy for placenta accreta and increta. Patients who were diagnosed with placenta accreta or increta preoperatively and intraoperatively and treated with Bakri balloon tamponade (Group 1) or caesarean hysterectomy (Group 2) were compared in regards to the postoperative results. Among the 36 patients diagnosed with placenta accreta or increta, 19 patients were treated with Bakri balloon tamponade while 17 cases were treated with hysterectomy. Intraoperative blood loss amount was 1794 ± 725 ml in G1, which was lower than that in G2 (2694 ± 893 ml). Blood transfusion amount was 2.7 ± 2.6 units in G1, lower than that in G2 (5.7 ± 2.4 units), too. Operation time was 64.5 ± 29 min and 140 ± 51 min in G1 and G2, respectively, showing significant differences between two groups. The success rate of Bakri balloon was determined as 84.21%. In conclusion, cases with placenta accreta/increta, with predicted placental detachment who are willing to preserve fertility, application of uterine balloon tamponade devices before the hysterectomy is encouraging with its advantages compared with the hysterectomy. Impact statement What is already known on this subject: Invasive placental anomalies are the most common indication of postpartum hysterectomy. Recently, uterine balloon tamponade was also included in the treatment modalities of postpartum haemorrhage.This study aimed to compare the postoperative results of UBT or hysterectomy for patients with placenta accreta and increta. What the results of this study add: In this study, the total amount of blood loss was higher in the caesarean hysterectomy group when compared with the Bakri balloon tamponade group. The mean transfusion requirement, mean operation time and hospitalisation period was significantly longer in the caesarean hysterectomy group. The success

  9. Clinical Study of Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) for Severe Pelvic Fracture and Intra Abdominal Hemorrhagic Shock using Continuous Vital Signs

    Science.gov (United States)

    2016-03-01

    aorta extending from the lowest renal artery to the aortic bifurcation. Despite the anatomic plausibility of Stannard’s technical description, it is...resuscitative thoracotomy. Zone II is the paravisceral segment and was proposed as a potential no-occlusion zone, while Zone III represents the infra- renal ...not a clinical report, simply an anatomic recommendation based on zones of aortic perfusion. The rationale behind REBOA follows the understanding

  10. Vasomotor wave and blood pressure response to erect posture after operation for aortic coarctation.

    OpenAIRE

    Sehested, J; Schultze, G

    1982-01-01

    Low frequency fluctuations (five to 10/min) in blood pressure, that is vasomotor waves, were recorded in the erect position in 18 patients operated upon for an isolated aortic coarctation six to eight and a half years previously, and compared with vasomotor waves in six age matched normotensive controls with respect to frequency and amplitude. The investigation was carried out by simultaneous intra-arterial blood pressure radiotelemetry recordings from the brachial and femoral arteries in all...

  11. Proposed radiological criteria for pre-operative determination of resectability in peritoneal-based malignancies

    International Nuclear Information System (INIS)

    Tan, Grace Hwei Ching; Chanyaputhipong, Jendana; Teo, Melissa Ching Ching; Kwek, Jin Wei; Hosseini, Reza; Tham, Chee Kian; Soo, Khee Chee

    2016-01-01

    The selection of patients for cytoreductive surgery (CRS) and hyperthermic intra-peritoneal chemotherapy infusion (HIPEC) is important, and relies heavily on imaging. However, it has been reported that Computer Tomographic (CT) scans may only achieve a low sensitivity of 33% for peritoneal disease. We propose a set of radiological criteria for pre-operative determination of resectability of peritoneal disease in peritoneal-based malignancies and validate this in our cohort of patients. A retrospective review of all patients who underwent laparotomy with a view for CRS and HIPEC, at the National Cancer Centre Singapore from January 2000 to April 2010, was performed. Intra-operative Peritoneal Cancer Index (PCI) scores were recorded. The pre-operative imaging was reviewed with a senior radiologist who was blinded, and recorded the radiological PCI scores (CT-PCI) and eight additional CT prognostic factors (CT-PF). The CT-PCI and CT-PF scores were then compared with the intra-operative findings to determine the radiological accuracy. The scores and the individual prognostic factors were then evaluated for their predictive ability for unresectability. Comparison of the CT-PCI and PCI scores showed a concordance correlation coefficient at 0.52 (95% CI 0.34–0.7). Accuracy was increased with the addition CT-PF. The presence of omental caking and ascites were predictors of unresectability. We propose a scoring system which is able to predict for unresectable disease with a specificity of 80% and a sensitivity of 62%. With our proposed criteria, and scoring system, the selection of patients for CRS and HIPEC can be improved, and unnecessary exploratory operations avoided.

  12. Reliability of the imaging software in the preoperative planning of the open-wedge high tibial osteotomy.

    Science.gov (United States)

    Lee, Yong Seuk; Kim, Min Kyu; Byun, Hae Won; Kim, Sang Bum; Kim, Jin Goo

    2015-03-01

    The purpose of this study was to verify a recently developed picture-archiving and communications system-photoshop method by comparing reliabilities between real-size paper template and the PACS-photoshop methods in preoperative planning of open-wedge high tibial osteotomy. A prospective case series was conducted, including patients with medial osteoarthritis undergoing open-wedge high tibial osteotomy. In the preoperative planning, the picture-archiving and communications system-photoshop method and real-size paper template method were used simultaneously in all patients. Preoperative hip-knee-ankle angle, height, and angle of the osteotomy were evaluated. The reliability of this newly devised method was evaluated, and the consistency between the two methods was also evaluated using intra-class correlation coefficient. Using the picture-archiving and communications system-photoshop method, the mean correction angle and height of osteotomy gap of rater-1 were 11.7° ± 3.6° and 10.7 ± 3.6 mm, respectively. The mean correction angle and height of osteotomy gap of rater-2 were 12.0 ± 2.6 and 10.8 ± 3.6, respectively. The inter- and intra-rater reliabilities of the correction angle were 0.956 ~ 0.979 and 0.980 ~ 0.992, respectively. The inter- and intra-rater reliabilities of the height of the osteotomy gap were 0.968 ~ 0.985 and 0.971 ~ 0.994, respectively (p photoshop method, mean values of the correction angle and height of the osteotomy gap were 11.9° ± 3.6° and 10.8 ± 3.6 mm, respectively. Consistency between the two methods by comparing the means of the correction angle and the height of the osteotomy gap were 0.985 and 0.985, respectively (p photoshop method enables direct measurement of the height of the osteotomy gap with high reliability.

  13. Contemporary results of aortic valve repair for congenital disease: lessons for management and staged strategy.

    Science.gov (United States)

    Vergnat, Mathieu; Asfour, Boulos; Arenz, Claudia; Suchowerskyj, Philipp; Bierbach, Benjamin; Schindler, Ehrenfried; Schneider, Martin; Hraska, Victor

    2017-09-01

    Any aortic valve (AoV) operation in children (repair, Ross or mechanical replacement) is a palliation and reinterventions are frequent. AoV repair is a temporary solution primarily aimed at allowing the patient to grow to an age when more definitive solutions are available. We retrospectively analysed AoV repair effectiveness across the whole age spectrum of children, excluding neonates and AoV disease secondary to congenital heart disease. From 2003 to 2015, 193 consecutive patients were included. The mean age was 9.2 ± 6.9 years (22% disease. The procedures performed were commissurotomy shaving (n = 74; 38%), leaflet replacement (n = 78; 40%), leaflet extension (n = 21; 11%) and neocommissure creation (n = 21; 11%). Post-repair geometry was tricuspid in 137 (71%) patients. The 10-year survival rate was 97.1%. Freedom from reoperation and replacement at 7 years was, respectively, 57% (95% confidence interval, 47-66) and 68% (95% confidence interval, 59-76). In multivariate analysis, balloon dilatation before 6 months, the absence of a developed commissure, a non-tricuspid post-repair geometry and cross-clamp duration were predictors for reoperation and replacement. After a mean follow-up period of 5.1 ± 3.0 years, 145 (75%) patients had a preserved native valve, with undisturbed valve function (peak gradient <40 mmHg, regurgitation ≤mild) in 113 (58%). Aortic valve repair in children is safe and effective in delaying the timing for more definitive solution. Surgical strategy should be individualized according to the age of the patient. Avoidance of early balloon dilatation and aiming for a tricuspid post-repair arrangement may improve outcomes. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  14. Durability of Aortic Valve Cusp Repair With and Without Annular Support.

    Science.gov (United States)

    Zeeshan, Ahmad; Idrees, Jay J; Johnston, Douglas R; Rajeswaran, Jeevanantham; Roselli, Eric E; Soltesz, Edward G; Gillinov, A Marc; Griffin, Brian; Grimm, Richard; Hammer, Donald F; Pettersson, Gösta B; Blackstone, Eugene H; Sabik, Joseph F; Svensson, Lars G

    2018-03-01

    To determine the value of aortic valve repair rather than replacement for valve dysfunction, we assessed late outcomes of various repair techniques in the contemporary era. From January 2001 to January 2011, aortic valve repair was planned in 1,124 patients. Techniques involved commissural figure-of-8 suspension sutures (n = 63 [6.2%]), cusp repair with commissuroplasty (n = 481 [48%]), debridement (n = 174 [17%]), free-margin plication (n = 271 [27%]) or resection (n = 75) or both, or annulus repair with resuspension (n = 230 [23%]), root reimplantation (n = 252 [25%]), or remodeling (n = 35 [3.5%]). Planned repair was aborted for replacement in 115 patients (10%); risk factors included greater severity of aortic regurgitation (AR; p = 0.0002) and valve calcification (p < 0.0001). In-hospital outcomes for the remaining 1,009 patients included death (12 [1.2%]), stroke (13 [1.3%]), and reoperation for valve dysfunction (14 [1.4%]). Freedom from aortic valve reoperation at 1, 5, and 10 years was 97%, 93%, and 90%, respectively. Figure-of-8 suspension sutures, valve resuspension, and root repair and replacement were least likely to require reoperation; cusp repair with commissural sutures, plication, and commissuroplasty was most likely (p < 0.05). Survival at 1, 5, and 10 years was 96%, 92%, and 83%. Immediate postoperative AR grade was none-mild (94%), moderate (5%), and severe (1%). At 10 years after repair, AR grade was none (20%), mild (33%), moderate (26%), and severe (21%). Patients undergoing root procedures were less likely to have higher-grade postoperative AR (p < 0.0001). Valve repair is effective and durable for treating aortic valve dysfunction. Greater severity of AR preoperatively is associated with higher likelihood of repair failure. Commissural figure-of-8 suspension sutures and repair with annular support have the best long-term durability. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights

  15. Application of Electrocautery Needle Knife Combined with Balloon Dilatation versus Balloon Dilatation in the Treatment of Tracheal Fibrotic Scar Stenosis.

    Science.gov (United States)

    Bo, Liyan; Li, Congcong; Chen, Min; Mu, Deguang; Jin, Faguang

    Electrocautery needle knives can largely reduce scar and granulation tissue hyperplasia and play an important role in treating patients with benign stricture. The aim of this retrospective study was to evaluate the efficacy and safety of electrocautery needle knife combined with balloon dilatation versus balloon dilatation alone in the treatment of tracheal stenosis caused by tracheal intubation or tracheotomy. We retrospectively analysed the clinical data of 43 patients with tracheal stenosis caused by tracheotomy or tracheal intubation in our department from January 2013 to January 2016. Among these 43 patients, 23 had simple web-like stenosis and 20 had complex steno sis. All patients were treated under general anaesthesia, and the treatment methods were (1) balloon dilatation alone, (2) needle knife excision of fibrotic tissue combined with balloon dilatation, and (3) needle knife radial incision of fibrotic tissue combined with balloon dilatation. After treatment the symptoms, such as shortness of breath, were markedly improved immediately in all cases. The stenosis degree of patients who were treated with the elec-trocautery needle knife combined with balloon dilatation had better improvement compared with that of those treated with balloon dilatation treatment alone after 3 months (0.45 ± 0.04 vs. 0.67 ± 0.05, p knife combined with balloon dilatation is an effective and safe treatment for tracheal fibrotic stenosis compared with balloon dilatation alone. © 2017 S. Karger AG, Basel.

  16. Neurodevelopmental outcomes after regional cerebral perfusion with neuromonitoring for neonatal aortic arch reconstruction.

    Science.gov (United States)

    Andropoulos, Dean B; Easley, R Blaine; Brady, Ken; McKenzie, E Dean; Heinle, Jeffrey S; Dickerson, Heather A; Shekerdemian, Lara S; Meador, Marcie; Eisenman, Carol; Hunter, Jill V; Turcich, Marie; Voigt, Robert G; Fraser, Charles D

    2013-02-01

    In this study we report magnetic resonance imaging (MRI) brain injury and 12-month neurodevelopmental outcomes when regional cerebral perfusion (RCP) is used for neonatal aortic arch reconstruction. Fifty-seven neonates receiving RCP during aortic arch reconstruction were enrolled in a prospective outcome study. RCP flows were determined by near-infrared spectroscopy and transcranial Doppler monitoring. Brain MRI was performed preoperatively and 7 days postoperatively. Bayley Scales of Infant Development III was performed at 12 months. Mean RCP time was 71 ± 28 minutes (range, 5 to 121 minutes) and mean flow was 56.6 ± 10.6 mL/kg/min. New postoperative MRI brain injury was seen in 40% of patients. For 35 RCP patients at age 12 months, mean Bayley Scales III Composite standard scores were: Cognitive, 100.1 ± 14.6 (range, 75 to 125); Language, 87.2 ± 15.0 (range, 62 to 132); and Motor, 87.9 ± 16.8 (range, 58 to 121). Increasing duration of RCP was not associated with adverse neurodevelopmental outcomes. Neonatal aortic arch repair with RCP using a neuromonitoring strategy results in 12-month cognitive outcomes that are at reference population norms. Language and motor outcomes are lower than the reference population norms by 0.8 to 0.9 standard deviations. The neurodevelopmental outcomes in this RCP cohort demonstrate that this technique is effective and safe in supporting the brain during neonatal aortic arch reconstruction. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Recent activities on the scientific ballooning in Japan

    International Nuclear Information System (INIS)

    Nisimura, J.; Hirosawa, H.

    1984-01-01

    Scientific ballooning is Japan has been organized by the Institute of Space and Astronautical Science, and about 15 balloons have been launched each year from Sanriku Balloon Center that belongs to this Institute. The balloon center is located in the northern part of Japan. The observations cover the field of X-ray, gamma-ray, infrared astronomy, cosmic rays, and atmospheric science. Systems of lon duration flights such as 'Boomerang Balloons', and fine attitude control systems were developed and widely applied to the scientific observations. International collaborative works were performed in Australia and Indonesia last year. Some details of these activities are reported and possible future collaborations with Braziian balloon group are also discussed. (Author) [pt

  18. The French balloon and sounding rocket space program

    Science.gov (United States)

    Coutin/Faye, S.; Sadourny, I.

    1987-08-01

    Stratospheric and long duration flight balloon programs are outlined. Open stratospheric balloons up to 1 million cu m volume are used to carry astronomy, solar system, aeronomy, stratosphere, biology, space physics, and geophysics experiments. The long duration balloons can carry 50 kg payloads at 20 to 30 km altitude for 10 days to several weeks. Pressurized stratospheric balloons, and infrared hot air balloons are used. They are used to study the dynamics of stratospheric waves and atmospheric water vapor. Laboratories participating in sounding rocket programs are listed.

  19. TMBM: Tethered Micro-Balloons on Mars

    Science.gov (United States)

    Sims, M. H.; Greeley, R.; Cutts, J. A.; Yavrouian, A. H.; Murbach, M.

    2000-01-01

    The use of balloons/aerobots on Mars has been under consideration for many years. Concepts include deployment during entry into the atmosphere from a carrier spacecraft, deployment from a lander, use of super-pressurized systems for long duration flights, 'hot-air' systems, etc. Principal advantages include the ability to obtain high-resolution data of the surface because balloons provide a low-altitude platform which moves relatively slowly. Work conducted within the last few years has removed many of the technical difficulties encountered in deployment and operation of balloons/aerobots on Mars. The concept proposed here (a tethered balloon released from a lander) uses a relatively simple approach which would enable aspects of Martian balloons to be tested while providing useful and potentially unique science results. Tethered Micro-Balloons on Mars (TMBM) would be carried to Mars on board a future lander as a stand-alone experiment having a total mass of one to two kilograms. It would consist of a helium balloon of up to 50 cubic meters that is inflated after landing and initially tethered to the lander. Its primary instrumentation would be a camera that would be carried to an altitude of up to tens of meters above the surface. Imaging data would be transmitted to the lander for inclusion in the mission data stream. The tether would be released in stages allowing different resolutions and coverage. In addition during this staged release a lander camera system may observe the motion of the balloon at various heights above he lander. Under some scenarios upon completion of the primary phase of TMBM operations, the tether would be cut, allowing TMBM to drift away from the landing site, during which images would be taken along the ground.

  20. Preoperative coiling of coexisting intracranial aneurysm and subsequent brain tumor surgery

    Energy Technology Data Exchange (ETDEWEB)

    Park, Keun Young; Kim, Byung Moon; Kim, Dong Joon [Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2016-11-15

    Few studies have investigated treatment strategies for brain tumor with a coexisting unruptured intracranial aneurysm (cUIA). The purpose of this study was to evaluate the safety and efficacy of preoperative coiling for cUIA, and subsequent brain tumor surgery. A total of 19 patients (mean age, 55.2 years; M:F = 4:15) underwent preoperative coiling for 23 cUIAs and subsequent brain tumor surgery. Primary brain tumors were meningiomas (n = 7, 36.8%), pituitary adenomas (n = 7, 36.8%), gliomas (n = 3, 15.8%), vestibular schwannoma (n = 1, 5.3%), and Rathke's cleft cyst (n = 1, 5.3%). cUIAs were located at the distal internal carotid artery (n = 9, 39.1%), anterior cerebral artery (n = 8, 34.8%), middle cerebral artery (n = 4, 17.4%), basilar artery top (n = 1, 4.3%), and posterior cerebral artery, P1 segment (n = 1, 4.3%). The outcomes of preoperative coiling of cUIA and subsequent brain tumor surgery were retrospectively evaluated. Single-microcatheter technique was used in 13 cases (56.5%), balloon-assisted in 4 cases (17.4%), double-microcatheter in 4 cases (17.4%), and stent-assisted in 2 cases (8.7%). Complete cUIA occlusion was achieved in 18 cases (78.3%), while residual neck occurred in 5 cases (21.7%). The only coiling-related complication was 1 transient ischemic attack (5.3%). Neurological deterioration did not occur in any patient during the period between coiling and tumor surgery. At the latest clinical follow-up (mean, 29 months; range, 2-120 months), 15 patients (78.9%) had favorable outcomes (modified Rankin Scale, 0-2), while 4 patients (21.1%) had unfavorable outcomes due to consequences of brain tumor surgery. Preoperative coiling and subsequent tumor surgery was safe and effective, making it a reasonable treatment option for patients with brain tumor and cUIA.

  1. Preoperative coiling of coexisting intracranial aneurysm and subsequent brain tumor surgery

    International Nuclear Information System (INIS)

    Park, Keun Young; Kim, Byung Moon; Kim, Dong Joon

    2016-01-01

    Few studies have investigated treatment strategies for brain tumor with a coexisting unruptured intracranial aneurysm (cUIA). The purpose of this study was to evaluate the safety and efficacy of preoperative coiling for cUIA, and subsequent brain tumor surgery. A total of 19 patients (mean age, 55.2 years; M:F = 4:15) underwent preoperative coiling for 23 cUIAs and subsequent brain tumor surgery. Primary brain tumors were meningiomas (n = 7, 36.8%), pituitary adenomas (n = 7, 36.8%), gliomas (n = 3, 15.8%), vestibular schwannoma (n = 1, 5.3%), and Rathke's cleft cyst (n = 1, 5.3%). cUIAs were located at the distal internal carotid artery (n = 9, 39.1%), anterior cerebral artery (n = 8, 34.8%), middle cerebral artery (n = 4, 17.4%), basilar artery top (n = 1, 4.3%), and posterior cerebral artery, P1 segment (n = 1, 4.3%). The outcomes of preoperative coiling of cUIA and subsequent brain tumor surgery were retrospectively evaluated. Single-microcatheter technique was used in 13 cases (56.5%), balloon-assisted in 4 cases (17.4%), double-microcatheter in 4 cases (17.4%), and stent-assisted in 2 cases (8.7%). Complete cUIA occlusion was achieved in 18 cases (78.3%), while residual neck occurred in 5 cases (21.7%). The only coiling-related complication was 1 transient ischemic attack (5.3%). Neurological deterioration did not occur in any patient during the period between coiling and tumor surgery. At the latest clinical follow-up (mean, 29 months; range, 2-120 months), 15 patients (78.9%) had favorable outcomes (modified Rankin Scale, 0-2), while 4 patients (21.1%) had unfavorable outcomes due to consequences of brain tumor surgery. Preoperative coiling and subsequent tumor surgery was safe and effective, making it a reasonable treatment option for patients with brain tumor and cUIA

  2. Aortic regurgitation after valve-sparing aortic root replacement: modes of failure.

    Science.gov (United States)

    Oka, Takanori; Okita, Yutaka; Matsumori, Masamichi; Okada, Kenji; Minami, Hitoshi; Munakata, Hiroshi; Inoue, Takeshi; Tanaka, Akiko; Sakamoto, Toshihito; Omura, Atsushi; Nomura, Takuo

    2011-11-01

    Despite the positive clinical results of valve-sparing aortic root replacement, little is known about the causes of reoperations and the modes of failure. From October 1999 to June 2010, 101 patients underwent valve-sparing aortic root replacement using the David reimplantation technique. The definition of aortic root repair failure included the following: (1) intraoperative conversion to the Bentall procedure; (2) reoperation performed because of aortic regurgitation; and (3) aortic regurgitation equal to or greater than a moderate degree at the follow-up. Sixteen patients were considered to have repair failure. Three patients required intraoperative conversion to valve replacement, 3 required reoperation within 3 months, and another 8 required reoperation during postoperative follow-up. At initial surgery 5 patients had moderate to severe aortic regurgitation, 6 patients had acute aortic dissections, 3 had Marfan syndrome, 2 had status post Ross operations, 3 had bicuspid aortic valves, and 1 had aortitis. Five patients had undergone cusp repair, including Arantius plication in 3 and plication at the commissure in 2. The causes of early failure in 6 patients included cusp perforation (3), cusp prolapse (3), and severe hemolysis (1). The causes of late failure in 10 patients included cusp prolapse (4), commissure dehiscence (3), torn cusp (2), and cusp retraction (1). Patients had valve replacements at a mean of 23 ± 20.9 months after reimplantation and survived. Causes of early failure after valve-sparing root replacement included technical failure, cusp lesions, and steep learning curve. Late failure was caused by aortic root wall degeneration due to gelatin-resorcin-formalin glue, cusp degeneration, or progression of cusp prolapse. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Overview of the NASA balloon R&D program

    Science.gov (United States)

    Smith, I. Steve, Jr.

    1994-01-01

    The catastrophic balloon failure during the first half of the 1980's identified the need for a comprehensive and continuing balloon research and development (R&D) commitment by NASA. Technical understanding was lacking in many of the disciplines and processes associated with scientific ballooning. A comprehensive balloon R&D plan was developed in 1986 and implemented in 1987. The objectives were to develop the understanding of balloon system performance, limitations, and failure mechanisms. The program consisted of five major technical areas: structures, performance and analysis, materials, chemistry and processing, and quality control. Research activitites have been conducted at NASA/Goddard Space Flight Center (GSFC)-Wallops Flight Facility (WFF), other NASA centers and government facilities, universities, and the balloon manufacturers. Several new and increased capabilities and resources have resulted from this activity. The findings, capabilities, and plan of the balloon R&D program are presented.

  4. Balloon pulmonary valvotomy – Not just a simple balloon dilatation

    Directory of Open Access Journals (Sweden)

    Subhendu Mohanty

    2014-07-01

    Full Text Available Balloon pulmonary valvotomy is the preferred mode of treatment in patients with isolated pulmonary valvar stenosis and has shown good long term results. It is generally considered a safe procedure with few complications. There have been however, case reports of potentially fatal acute severe pulmonary edema occurring after the procedure in some patients. The cause of this complication and its pathophysiology is still not clear. Its occurrence is also infrequent with less than 5 cases reported till now. We report a case of pulmonary valvar stenosis which developed acute severe refractory pulmonary edema immediately after balloon pulmonary valvotomy.

  5. Aortic intramural hematoma : assessment of clinical and radiological features in comparison to acute aortic dissection

    International Nuclear Information System (INIS)

    Yoon, Kwon Ha; Hwang, Jae Cheol; Lee, Jin Seong; Kang, Duk Hyun; Song, Jae Kwan; Song, Koun Sik; Lim, Tae Hwan

    1996-01-01

    To compare the clinical and radiological features of aortic intramural hematoma(IMH) to those of acute aortic dissection(AD). We analyzed the clinical and radiological features of 12 patients with aortic IMH and 43 patients with acute AD. In aortic IMH, the diagnoses were made by means of both CT and transesophageal echocardiography(TEE) and included two surgically proven cases. In acute AD, the diagnoses were made by means of CT and TEE and included 21 surgically proven cases. We compared patients ages, etiologies, the extent of the disease, the presence or absence of aortic branch involvement, complications, and outcomes. Aortic IMH tended to develop in older patients (67.8±7.9 vs. 50.4±13.4, P .05). In aortic IMH, there was no involvement of aortic branches, whereas in acute AD, 14(33%) patients showed involvement of one or more aortic branches. Complications of aortic IMH included pericardial effusion (n=2) and pleural effusion (n=4);in acute AD, pericardial effusion (n=7), pleural effusion (n=4), aortic insufficiency (n=8), cerebral infarction (n=3), renal infarction (n=4) and spinal infarction (n=1) were seen. There was one (8%) death due to aortic IMH and ten (23%) deaths due to acute AD (p<.01). Aortic IMH is characterized by its occurrence in older patients with hypertension, a less frequent incidence of complications, and a more favorable outcome than acute AD

  6. Transcatheter aortic valve replacement

    Science.gov (United States)

    ... gov/ency/article/007684.htm Transcatheter aortic valve replacement To use the sharing features on this page, please enable JavaScript. Transcatheter aortic valve replacement (TAVR) is surgery to replace the aortic valve. ...

  7. Left Ventricular Assist Device Implantation with Concomitant Aortic Valve and Ascending Aortic Replacement.

    Science.gov (United States)

    Huenges, Katharina; Panholzer, Bernd; Cremer, Jochen; Haneya, Assad

    2018-01-01

    Left ventricular assist device (LVAD) is nowadays a routine therapy for patients with advanced heart failure. We present the case of a 74-year-old male patient who was admitted to our center with terminal heart failure in dilated cardiomyopathy and ascending aortic aneurysm with aortic valve regurgitation. The LVAD implantation with simultaneous aortic valve and supracoronary ascending aortic replacement was successfully performed.

  8. Early and mid-term results with the Growth Stent--a possible concept for transcatheter treatment of aortic coarctation from infancy to adulthood by stent implantation?

    Science.gov (United States)

    Ewert, Peter; Peters, Bjoern; Nagdyman, Nicole; Miera, Oliver; Kühne, Titus; Berger, Felix

    2008-01-01

    Evaluation of the Growth Stent-a stent consisting of two stent halves connected by reabsorbable sutures-for the treatment of aortic coarctation in infants. Surveillance study of 13 Growth Stents implanted in 12 patients aged 1-15 months (median 5 months). Body weight ranged from 3.4-12.8 kg (median 5.4 kg). Eight patients suffered from aortic (re-)coarctation, four of them from stenosis of the aortic anastomosis after a Norwood I procedure. The follow-up period was 24 months (11-51 months). Pressure gradients immediately after stent implantation decreased from 30 mm Hg (range 20-50 mm Hg) to 8 mm Hg (range 0-15 mm Hg). Five patients had one (3 pts) or two (2 pts) balloon dilations 3-28 months (median 12 months) after Growth Stent implantation. The median pressure gradient decreased from 25 mm Hg (range 15-30 mm Hg) to 15 mm Hg (range 5-25 mm Hg). Six patients received a large stent after 19-34 months. Median body weight was 11.8 kg (9.4-15 kg). The Growth Stent is suitable for the acute treatment of aortic coarctation in infants and can be overstented later on--if necessary--with a larger stent without causing restriction. Copyright 2008 Wiley-Liss, Inc.

  9. Impact of Discordant Views in the Management of Descending Thoracic Aortic Aneurysm.

    Science.gov (United States)

    Chiu, Peter; Sailer, Anna-Margaretha; Baiocchi, Michael; Goldstone, Andrew B; Schaffer, Justin M; Trojan, Jeff; Fleischmann, Dominik; Mitchell, R Scott; Miller, D Craig; Dake, Michael D; Woo, Y Joseph; Lee, Jason T; Fischbein, Michael P

    2017-01-01

    Thoracic endovascular aortic repair has a lower perceived risk than open surgical repair and has become an increasingly popular alternative. Whether general consensus exists regarding candidacy for either operation among open and endovascular specialists is unknown. A retrospective review of isolated descending thoracic aortic aneurysm at our institution between January 2005 and October 2015 was performed, excluding trauma and dissection. Two cardiac surgeons, 2 cardiovascular surgeons, 1 vascular surgeon, and 1 interventional radiologist gave their preference for open vs endovascular repair. Interobserver agreement was assessed with the kappa coefficient. k-means clustering agnostically grouped various patterns of agreement. The mean rating was predicted using least absolute shrinkage and selection operator regression. Negative binomial regression predicted the discrepancy between our panel of raters and the historical operation. Generalized estimating equation modeling was then used to evaluate the association between the extent of discrepancy and the adverse perioperative outcome. There were 77 patients with preoperative imaging studies. Pairwise interobserver agreement was only fair (median weighted kappa 0.270 [interquartile range 0.211-0.404]). Increasing age and proximal neck length predicted an increasing preference for thoracic endovascular aortic repair in our panel; larger proximal neck diameter predicted a general preference for open surgical repair. Increasing proximal neck diameter predicted a larger discrepancy between our panel and the historical operation. Greater discrepancy was associated with adverse outcome. Substantial disagreement existed among our panel, and an exploratory analysis of the effect of increasing discrepancy demonstrated an association with adverse perioperative outcome. An investigation of the effect of a thoracic aortic team with open and endovascular specialists is warranted. Copyright © 2017 Elsevier Inc. All rights

  10. Particle Astrophysics in NASA's Long Duration Balloon Program

    International Nuclear Information System (INIS)

    Gorham, Peter W.

    2013-01-01

    A century after Viktor Hess' discovery of cosmic rays, balloon flights still play a central role in the investigation of cosmic rays over nearly their entire spectrum. We report on the current status of NASA balloon program for particle astrophysics, with particular emphasis on the very successful Antarctic long-duration balloon program, and new developments in the progress toward ultra-long duration balloons

  11. Infected aortic aneurysm and inflammatory aortic aneurysm. In search of an optimal differential diagnosis

    International Nuclear Information System (INIS)

    Ishizaka, Nobukazu; Sohmiya, Koichi; Miyamura, Masatoshi; Umeda, Tatsuya; Tsuji, Motomu; Katsumata, Takahiro; Miyata, Tetsuro

    2012-01-01

    Infected aortic aneurysm and inflammatory aortic aneurysm each account for a minor fraction of the total incidence of aortic aneurysm and are associated with periaortic inflammation. Despite the similarity, infected aortic aneurysm generally shows a more rapid change in clinical condition, leading to a fatal outcome; in addition, delayed diagnosis and misuse of corticosteroid or immunosuppressing drugs may lead to uncontrolled growth of microorganisms. Therefore, it is mandatory that detection of aortic aneurysm is followed by accurate differential diagnosis. In general, infected aortic aneurysm appears usually as a saccular form aneurysm with nodularity, irregular configuration; however, the differential diagnosis may not be easy sometimes for the following reasons: symptoms, such as abdominal and/or back pain and fever, and blood test abnormalities, such as elevated C-reactive protein and enhanced erythrocyte sedimentation rate, are common in infected aortic aneurysm, but they are not found infrequently in inflammatory aortic aneurysm; some inflammatory aortic aneurysms are immunoglobulin (Ig) G4-related, but not all of them; the prevalence of IgG4 positivity in infected aortic aneurysm has not been well investigated; enhanced uptake of 18F-fluorodeoxyglucose (FDG) by 18F-FDG-positron emission tomography may not distinguish between inflammation mediated by autoimmunity and that mediated by microorganism infection. Here we discuss the characteristics of these two forms of aortic aneurysm and the points of which we have to be aware before reaching a final diagnosis. (author)

  12. Morphological risk factors of stroke during thoracic endovascular aortic repair.

    Science.gov (United States)

    Kotelis, Drosos; Bischoff, Moritz S; Jobst, Bertram; von Tengg-Kobligk, Hendrik; Hinz, Ulf; Geisbüsch, Philipp; Böckler, Dittmar

    2012-12-01

    This study aims to identify independent factors correlating to an increased risk of perioperative stroke during thoracic endovascular aortic repair (TEVAR). A prospective maintained TEVAR database, medical records, and imaging studies of 300 patients (205 men; median age of all, 66 years, range 21-89), who underwent TEVAR between March 1997 and February 2011, were reviewed. Preoperative CT data sets were reviewed by two experienced radiologists with focus on the atheroma burden in the aortic arch (grade I, normal, to grade V, ulcerated or pedunculated atheroma). Aortic arch geometry (arch types I-III) was documented. Further parameters included in the univariate analysis were age, gender, urgency of repair, duration of procedure, adenosine-induced cardiac arrest or rapid pacing, proximal landing zone, left subclavian artery (LSA) coverage, and number of stent grafts. Multivariate logistic regression analysis was performed to assess the independent correlations of potential risk factors. Atherosclerotic aneurysm was the most common pathology (44%). One hundred and fifty-four of our patients (51%) were treated under urgent or emergent conditions. Seventeen percent of all patients had significant arch atheroma (grade IV or V), and 43% had a steep type III aortic arch. The perioperative stroke was 4% (12 patients; median age, 73 years, range 31-78). Two strokes were lethal (0.7%). All strokes were classified as embolic based on imaging characteristics. In eight patients, strokes were located in the left cerebral hemisphere (seven of them in the anterior and one in the posterior circulation). Four stroke patients (one in the left posterior circulation) underwent LSA coverage without revascularization. Three stroke patients had severe arch atheroma grade V. Five patients suffering stroke were recognized to have a type III aortic arch. Strokes were equally distributed between zones 0-2 vs. 3-4 (n = 6 each, 5 vs. 3.3%). The highest incidence was found in zone 1 (11

  13. Laser welding of balloon catheters

    Science.gov (United States)

    Flanagan, Aidan J.

    2003-03-01

    The balloon catheter is one of the principal instruments of non-invasive vascular surgery. It is used most commonly for angioplasty (and in recent years for delivering stents) at a multitude of different sites in the body from small arteries in the heart to the bilary duct. It is composed of a polymer balloon that is attached to a polymer shaft at two points called the distal and proximal bonds. The diverse utility of balloon catheters means a large range of component sizes and materials are used during production; this leads to a complexity of bonding methods and technology. The proximal and distal bonds have been conventionally made using cyanoacrylate or UV curing glue, however with performance requirements of bond strength, flexibility, profile, and manufacturing costs these bonds are increasingly being made by welding using laser, RF, and Hot Jaw methods. This paper describes laser welding of distal and proximal balloon bonds and details beam delivery, bonding mechanisms, bond shaping, laser types, and wavelength choice.

  14. NASA Langley Research Center tethered balloon systems

    Science.gov (United States)

    Owens, Thomas L.; Storey, Richard W.; Youngbluth, Otto

    1987-01-01

    The NASA Langley Research Center tethered balloon system operations are covered in this report for the period of 1979 through 1983. Meteorological data, ozone concentrations, and other data were obtained from in situ measurements. The large tethered balloon had a lifting capability of 30 kilograms to 2500 meters. The report includes descriptions of the various components of the balloon systems such as the balloons, the sensors, the electronics, and the hardware. Several photographs of the system are included as well as a list of projects including the types of data gathered.

  15. An investigation into the causes of unexpected intra-operative transoesophageal echocardiography findings.

    Science.gov (United States)

    Skinner, H J; Mahmoud, A; Uddin, A; Mathew, T

    2012-04-01

    There is uncertainty regarding echocardiography before cardiac surgery, especially with regard to timing and disease progression as well as potential errors. We investigated the causes of unexpected intra-operative transoesophageal echocardiography findings by performing a 33-month audit. We found that there were 50/797 (6%) unexpected findings that led to an alteration in surgical strategy in 34 (4%) patients. Of the unexpected findings, 25 (50%) were unrelated to pre-operative pathology. After reviewing pre-operative studies and reports, unexpected findings were found to be due to: reporting errors in 20 patients (44%); limitations in transthoracic compared to transoesophageal echocardiography in 14 patients (30%); disease progression in 10 patients (22%); and inter-observer variability in two patients (4%). We identified six reports out of 797 (0.8%) that contained potentially serious errors. Surgical management changed in 18/20 (90%) patients in whom the unexpected change was due to reporting error, compared to 16/30 (53%) patients whose pre-operative echocardiogram was correctly reported (p = 0.006). Our study suggests that pre-operative echocardiography reporting errors are common and important. Anaesthesia © 2012 The Association of Anaesthetists of Great Britain and Ireland.

  16. Minocycline Effectively Protects the Rabbit's Spinal Cord From Aortic Occlusion-Related Ischemia.

    Science.gov (United States)

    Drenger, Benjamin; Fellig, Yakov; Ben-David, Dror; Mintz, Bella; Idrees, Suhel; Or, Omer; Kaplan, Leon; Ginosar, Yehuda; Barzilay, Yair

    2016-04-01

    To identify the minocycline anti-inflammatory and antiapoptotic mechanisms through which it is believed to exert spinal cord protection during aortic occlusion in the rabbit model. An animal model of aortic occlusion-related spinal cord ischemia. Randomized study with a control group and pre-ischemia and post-ischemia escalating doses of minocycline to high-dose minocycline in the presence of either hyperglycemia, a pro-apoptotic maneuver, or wortmannin, a specific phosphatidylinositol 3-kinase antagonist. Tertiary medical center and school of medicine laboratory. Laboratory animals-rabbits. Balloon obstruction of infrarenal aorta introduced via femoral artery incision. Severe hindlimb paralysis (mean Tarlov score 0.36±0.81 out of 3) was observed in all the control group animals (9 of 11 with paraplegia and 2 of 11 with paraparesis) compared with 11 of 12 neurologically intact animals (mean Tarlov score 2.58±0.90 [p = 0.001 compared with control]) in the high-dose minocycline group. This protective effect was observed partially during a state of hyperglycemia and was completely abrogated by wortmannin. Minocycline administration resulted in higher neurologic scores (p = 0.003) and a shift to viable neurons and more apoptotic-stained nuclei resulting from reduced necrosis (p = 0.001). In a rabbit model of infrarenal aortic occlusion, minocycline effectively reduced paraplegia by increasing the number of viable neurons in a dose-dependent manner. Its action was completely abrogated by inhibiting the phosphatidylinositol 3-kinase pathway and was inhibited partially by the pro-apoptotic hyperglycemia maneuver, indicating that the activation of cell salvage pathways and mitochondrial sites are possible targets of minocycline action in an ischemic spinal cord. Copyright © 2016. Published by Elsevier Inc.

  17. Aortic root surgery in Marfan syndrome: Comparison of aortic valve-sparing reimplantation versus composite grafting.

    Science.gov (United States)

    Karck, Matthias; Kallenbach, Klaus; Hagl, Christian; Rhein, Christine; Leyh, Rainer; Haverich, Axel

    2004-02-01

    The objective of this study was to compare the results of aortic valve-sparing reimplantation and aortic root replacement with mechanical valve conduits in patients with Marfan syndrome undergoing operation for aortic root aneurysms. Patients and methods Between March 1979 and April 2002, 119 patients with clinical evidence of Marfan syndrome underwent composite graft replacement with mechanical valve conduits (n = 74) or aortic valve-sparing reimplantation according to David (n = 45). The underlying causes were aortic dissection type A (43 patients) and aneurysms (76 patients). Patients undergoing aortic valve reimplantation were younger compared with patients undergoing composite grafting (28 vs 35 years, P =.002) and had longer intraoperative aortic crossclamp times (125 vs 78 minutes, P valve reimplantation (P =.15). Mean follow-up was 30 months for patients undergoing aortic valve reimplantation and 114 months for patients undergoing composite grafting. Freedom from reoperation and death after 5 years postoperatively was 92% and 89% in patients undergoing composite grafting and 84% and 96% in patients undergoing aortic valve reimplantation (P =.31; P =.54), respectively. Thromboembolic complications or late postoperative bleeding occurred in 17 patients undergoing composite grafting, and an early postoperative event occurred in 1 patient undergoing aortic valve reimplantation. The results of aortic valve reimplantation and composite grafting of the aortic valve and ascending aorta with mechanical valve conduits are similar with regard to early and mid-term postoperative mortality and to the incidence of late reoperations in patients with Marfan syndrome. The low risk of thromboembolic or bleeding complications favors aortic valve reimplantation in these patients.

  18. Endoluminal Treatment of Ruptured Abdominal Aortic Aneurysm with Small Intestinal Submucosa Sandwich Endografts: A Pilot Study in Sheep

    International Nuclear Information System (INIS)

    Yamada, Katsuyuki; Pavcnik, Dusan; Uchida, Barry T.; Timmermans, Hans A.; Corless, Christopher L.; Yin, Qiang; Yamakado, Koichiro; Wha Park, Joong; Roesch, Josef; Keller, Frederick S.; Sato, Morio; Yamada, Ryusaku

    2001-01-01

    Purpose: To evaluate efficacy of small intestinal submucosa (SIS) Sandwich endografts for the treatment of acute rupture of abdominal aortic aneurysms (AAA) and to explore the short-term reaction of the aorta to this material.Methods: In eight adult sheep, an infrarenal AAA was created transluminally by dilation of a short Palmaz stent. In six sheep, the aneurysm was then ruptured by overdilation of the stent with a large angioplasty balloon. Two sheep with AAAs that were not ruptured served as controls. A SIS Sandwich endograft, consisting of a Z stent frame with 5 bodies and covered inside and out with SIS, was used to exclude the ruptured and non-ruptured AAAs. Follow-up aortography was done immediately after the procedure and before sacrifice at 4, 8, or 12 weeks. Autopsy and histologic studies followed.Results: Endograft placement was successful in all eight sheep. Both ruptured and non-ruptured AAAs were successfully excluded. Three animals with AAA rupture developed hind leg paralysis due to compromise of the arterial supply to the lower spinal cord and were sacrificed 1 day after the procedure. In five animals, three with rupture and two controls, follow-up aortograms revealed no aortic stenoses and no perigraft leaks. Gross and histologic studies revealed incorporation of the endografts into the aortic wall with replacement of SIS by dense neointima that was completely endothelialized in areas where the endograft was in direct contact with the aortic wall. In central portions of the endograft, in contact with the thrombosed aneurysm, endothelialization was incomplete even at 12 weeks.Conclusion: The SIS Sandwich endografts effectively excluded simple AAAs and ruptured AAAs. They were rapidly incorporated into the aortic wall. A detailed long-term study is warranted

  19. Heat Transfer Model for Hot Air Balloons

    Science.gov (United States)

    Llado-Gambin, Adriana

    A heat transfer model and analysis for hot air balloons is presented in this work, backed with a flow simulation using SolidWorks. The objective is to understand the major heat losses in the balloon and to identify the parameters that affect most its flight performance. Results show that more than 70% of the heat losses are due to the emitted radiation from the balloon envelope and that convection losses represent around 20% of the total. A simulated heating source is also included in the modeling based on typical thermal input from a balloon propane burner. The burner duty cycle to keep a constant altitude can vary from 10% to 28% depending on the atmospheric conditions, and the ambient temperature is the parameter that most affects the total thermal input needed. The simulation and analysis also predict that the gas temperature inside the balloon decreases at a rate of -0.25 K/s when there is no burner activity, and it increases at a rate of +1 K/s when the balloon pilot operates the burner. The results were compared to actual flight data and they show very good agreement indicating that the major physical processes responsible for balloon performance aloft are accurately captured in the simulation.

  20. ECG-gated computed tomography: a new role for patients with suspected aortic prosthetic valve endocarditis

    Energy Technology Data Exchange (ETDEWEB)

    Fagman, Erika; Flinck, Agneta; Lamm, Carl [Sahlgrenska University Hospital, Department of Radiology, Gothenburg (Sweden); Perrotta, Sossio [Sahlgrenska University Hospital, Department of Cardiovascular Surgery and Anaesthesia, Gothenburg (Sweden); Bech-Hanssen, Odd [Sahlgrenska University Hospital, Department of Clinical Physiology, Gothenburg (Sweden); Sahlgrenska University Hospital, Department of Cardiology, Gothenburg (Sweden); Olaison, Lars [Sahlgrenska University Hospital, Department of Infectious Diseases, Gothenburg (Sweden); Svensson, Gunnar [Sahlgrenska University Hospital, Department of Cardiovascular Surgery and Anaesthesia, Gothenburg (Sweden); The Sahlgrenska Academy at the University of Gothenburg, Department of Molecular and Clinical Medicine, Institute of Medicine, Gothenburg (Sweden)

    2012-11-15

    The aim of this prospective study was to investigate the agreement in findings between ECG-gated CT and transoesophageal echocardiography (TEE) in patients with aortic prosthetic valve endocarditis (PVE). Twenty-seven consecutive patients with PVE underwent 64-slice ECG-gated CT and TEE and the results were compared. Imaging was compared with surgical findings (surgery was performed in 16 patients). TEE suggested the presence of PVE in all patients [thickened aortic wall (n = 17), vegetation (n = 13), abscess (n = 16), valvular dehiscence (n = 10)]. ECG-gated CT was positive in 25 patients (93 %) [thickened aortic wall (n = 19), vegetation (n = 7), abscess (n = 18), valvular dehiscence (n = 7)]. The strength of agreement [kappa (95 % CI)] between ECG-gated CT and TEE was very good for thickened wall [0.83 (0.62-1.0)], good for abscess [0.68 (0.40-0.97)] and dehiscence [0.75 (0.48-1.0)], and moderate for vegetation [0.55 (0.26-0.88)]. The agreement was good between surgical findings (abscess, vegetation and dehiscence) and imaging for ECG-gated CT [0.66 (0.49-0.87)] and TEE [0.79 (0.62-0.96)] and very good for the combination of ECG-gated CT and TEE [0.88 (0.74-1.0)]. Our results indicate that ECG-gated CT has comparable diagnostic performance to TEE and may be a valuable complement in the preoperative evaluation of patients with aortic PVE. (orig.)

  1. ECG-gated computed tomography: a new role for patients with suspected aortic prosthetic valve endocarditis

    International Nuclear Information System (INIS)

    Fagman, Erika; Flinck, Agneta; Lamm, Carl; Perrotta, Sossio; Bech-Hanssen, Odd; Olaison, Lars; Svensson, Gunnar

    2012-01-01

    The aim of this prospective study was to investigate the agreement in findings between ECG-gated CT and transoesophageal echocardiography (TEE) in patients with aortic prosthetic valve endocarditis (PVE). Twenty-seven consecutive patients with PVE underwent 64-slice ECG-gated CT and TEE and the results were compared. Imaging was compared with surgical findings (surgery was performed in 16 patients). TEE suggested the presence of PVE in all patients [thickened aortic wall (n = 17), vegetation (n = 13), abscess (n = 16), valvular dehiscence (n = 10)]. ECG-gated CT was positive in 25 patients (93 %) [thickened aortic wall (n = 19), vegetation (n = 7), abscess (n = 18), valvular dehiscence (n = 7)]. The strength of agreement [kappa (95 % CI)] between ECG-gated CT and TEE was very good for thickened wall [0.83 (0.62-1.0)], good for abscess [0.68 (0.40-0.97)] and dehiscence [0.75 (0.48-1.0)], and moderate for vegetation [0.55 (0.26-0.88)]. The agreement was good between surgical findings (abscess, vegetation and dehiscence) and imaging for ECG-gated CT [0.66 (0.49-0.87)] and TEE [0.79 (0.62-0.96)] and very good for the combination of ECG-gated CT and TEE [0.88 (0.74-1.0)]. Our results indicate that ECG-gated CT has comparable diagnostic performance to TEE and may be a valuable complement in the preoperative evaluation of patients with aortic PVE. (orig.)

  2. Transcatheter valve-in-valve implantation due to severe aortic regurgitation in a degenerated aortic homograft

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Engstrøm, Thomas; Søndergaard, Lars

    2009-01-01

    Transcatheter aortic valve implantation (TAVI) in severe aortic stenosis has proven to be a feasible and effective treatment modality for inoperable patients. Until now, neither aortic regurgitation nor degenerated bioprostheses has been an indication for TAVI. However, this article reports...... a successful valve-in-valve implantation of a CoreValve aortic valve prosthesis through the right subclavian artery in a case of severe aortic regurgitation within a degenerated aortic homograft. The case exemplifies the possibilities of expanding the indications for TAVI, as well as other vascular access...

  3. Deployment Instabilities of Lobed-Pumpkin Balloon

    Science.gov (United States)

    Nakashino, Kyoichi

    A lobed-pumpkin balloon, currently being developed in ISAS/JAXA as well as in NASA, is a promising vehicle for long duration scientific observations in the stratosphere. Recent ground and flight experiments, however, have revealed that the balloon has deployment instabilities under certain conditions. In order to overcome the instability problems, a next generation SPB called 'tawara' type balloon has been proposed, in which an additional cylindrical part is appended to the standard lobed-pumpkin balloon. The present study investigates the deployment stability of tawara type SPB in comparison to that of standard lobed-pumpkin SPB through eigenvalue analysis on the basis of finite element methods. Our numerical results show that tawara type SPB enjoys excellent deployment performance over the standard lobed-pumpkin SPBs.

  4. Gigantic balloon type artificial lightning generator

    Energy Technology Data Exchange (ETDEWEB)

    Horii; kenji

    1988-09-05

    This paper outlines a hot-air balloon type Van de Graaf 50-MV generator which can generate a 50,000,000 V, 0.2 to 0.3 coulomb artificial lightning comparable to natural lightning discharge and reports the results of investigation on discharging experiments conducted using this apparatus. The subjects covered are as follows: (1) Outline of the hot-air balloon type Van de Graaf 50-MV generator, (2) electric characteristics of the Van de Graaf 50-MV generator, (3) charge transfer with film and balloon charging, (4) the load of the balloon and buoyancy calculation, (5) leakage of charges, (6) study of charging experiments, and (7) evaluation of the apparatus and its method and problems to be solved. (4 figs, 4 tabs, 4 refs)

  5. Balloon cell nevus of the iris.

    Science.gov (United States)

    Morcos, Mohib W; Odashiro, Alexandre; Bazin, Richard; Pereira, Patricia Rusa; O'Meara, Aisling; Burnier, Miguel N

    2014-12-01

    Balloon cell nevus is a rare histopathological lesion characterized by a predominance of large, vesicular and clear cells, called balloon cells. There is only 1 case of balloon cell nevus of the iris reported in the literature. A 55 year-old man presented a pigmented elevated lesion in the right iris since the age of 12 years old. The lesion had been growing for the past 2 years and excision was performed. Histopathological examination showed a balloon cell nevus composed of clear and vacuolated cells without atypia. A typical spindle cell nevus of the iris was also observed. The differential diagnosis included xanthomatous lesions, brown adipocyte or other adipocytic lesions, clear cell hidradenoma, metastatic clear cell carcinoma of the kidney and clear cell sarcoma. The tumor was positive for Melan A, S100 protein and HMB45. Balloon cell nevus of the iris is rare but should be considered in the differential diagnosis of melanocytic lesions of the iris. Copyright © 2014 Elsevier GmbH. All rights reserved.

  6. Aortic valve-sparing operations in aortic root aneurysms: remodeling or reimplantation?

    Science.gov (United States)

    Rahnavardi, Mohammad; Yan, Tristan D; Bannon, Paul G; Wilson, Michael K

    2011-08-01

    A best evidence topic was written according to a structured protocol. The question addressed was whether the reimplantation (David) technique or the remodeling (Yacoub) technique provides the optimum event free survival in patients with an aortic root aneurysm suitable for an aortic valve-sparing operation. In total, 392 papers were found using the reported search criteria, of which 14 papers provided the best evidence to answer the clinical question. A total of 1338 patients (Yacoub technique in 606 and David technique in 732) from 13 centres were included. In most series, cardiopulmonary bypass time and aortic cross-clamp time were longer for the David technique compared to the Yacoub technique. Early mortality was comparable between the two techniques (0-6.9% for the Yacoub technique and 0-6% for the David technique). There is a tendency for a higher freedom from significant long-term aortic insufficiency in the David group than the Yacoub group, which does not necessarily result in a higher reoperation rate in the Yacoub group. In the largest series reported, freedom from a moderate-to-severe aortic insufficiency at 12 years was 82.6 ± 6.2% in the Yacoub and 91.0 ± 3.8% in the David group (P=0.035). Freedom from reoperation at the same time point was 90.4 ± 4.7% in the Yacoub group and 97.4 ± 2.2% in the David group (P=0.09). In another series, freedom from reoperation at a follow-up time of about four years was 89 ± 4% in the Yacoub group and 98 ± 2% in the David group. Although some authors merely preferred the Yacoub technique for a bicuspid aortic valve, the accumulated evidence in the current review indicates comparable results for both techniques in a bicuspid aortic valve. Current evidence is in favour of the David rather than the Yacoub technique in pathologies such as Marfan syndrome, acute type A aortic dissection, and excessive annular dilatation that may impair aortic root integrity. Careful selection of patients for each technique and

  7. Incidence and progression of mild aortic regurgitation after Tirone David reimplantation valve-sparing aortic root replacement.

    Science.gov (United States)

    Stephens, Elizabeth H; Liang, David H; Kvitting, John-Peder Escobar; Kari, Fabian A; Fischbein, Michael P; Mitchell, R Scott; Miller, D Craig

    2014-01-01

    The study objective was to determine whether recurrent or residual mild aortic regurgitation, which occurs after valve-sparing aortic root replacement, progresses over time. Between 2003 and 2008, 154 patients underwent Tirone David-V valve-sparing aortic root replacement; 96 patients (62%) had both 1-year (median, 12 ± 4 months) and mid-term (62 ± 22 months) transthoracic echocardiograms available for analysis. Age of patients averaged 38 ± 13 years, 71% were male, 31% had a bicuspid aortic valve, 41% had Marfan syndrome, and 51% underwent aortic valve repair, predominantly cusp free margin shortening. Forty-one patients (43%) had mild aortic regurgitation on 1-year echocardiogram. In 85% of patients (n = 35), mild aortic regurgitation remained stable on the most recent echocardiogram (median, 57 ± 20 months); progression to moderate aortic regurgitation occurred in 5 patients (12%) at a median of 28 ± 18 months and remained stable thereafter; severe aortic regurgitation developed in 1 patient, eventually requiring reoperation. Five patients (5%) had moderate aortic regurgitation at 1 year, which did not progress subsequently. Two patients (2%) had more than moderate aortic regurgitation at 1 year, and both ultimately required reoperation. Although mild aortic regurgitation occurs frequently after valve-sparing aortic root replacement, it is unlikely to progress over the next 5 years and should not be interpreted as failure of the valve-preservation concept. Further, we suggest that mild aortic regurgitation should not be considered nonstructural valve dysfunction, as the 2008 valve reporting guidelines would indicate. We need 10- to 15-year follow-up to learn the long-term clinical consequences of mild aortic regurgitation early after valve-sparing aortic root replacement. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  8. Mars Solar Balloon Lander, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The Mars Solar Balloon Lander (MSBL) is a novel concept which utilizes the capability of solar-heated hot air balloons to perform soft landings of scientific...

  9. Bovine aortic arch: A novel association with thoracic aortic dilation

    International Nuclear Information System (INIS)

    Malone, C.D.; Urbania, T.H.; Crook, S.E.S.; Hope, M.D.

    2012-01-01

    Aim: To investigate whether there is a link between bovine arch and thoracic aortic aneurysm. Materials and methods: Computed tomography (CT) and magnetic resonance imaging (MRI) images of the thorax of 191 patients with dilated thoracic aortas and 391 consecutive, unselected patients as controls were retrospectively reviewed. Bovine arch was considered present if either a shared origin of the left common carotid and innominate arteries or an origin of the left common carotid from the innominate artery was identified. A chi-square test was used to evaluate the significance of differences between subgroups. Results: A trend towards increased prevalence of bovine arch was seen in patients with dilated aortas (26.2%) compared to controls (20.5%, p = 0.12). The association was statistically significant in patients over 70 years old (31.9%, p = 0.019) and when dilation involved the aortic arch (47.6%, p = 0.003). Conclusions: An association between bovine arch and aortic dilation is seen in older patients, and when dilation involves the aortic arch. Bovine arch should be considered a potential risk factor for thoracic aortic aneurysm.

  10. Modification of conservative treatment of heterotopic cervical pregnancy by Foley catheter balloon fixation with cerclage sutures at the level of the external cervical os: a case report

    Directory of Open Access Journals (Sweden)

    Vujisic Sanja

    2010-07-01

    Full Text Available Abstract Introduction Conservative treatment of a heterotopic cervical pregnancy was performed with a modification of the fixation of a Foley catheter at the level of the external cervical os, followed by the ligature of the descending cervical branches of the uterine arteries and systemic methotrexate application. Case presentation A 34-year-old Caucasian woman was diagnosed with double gestation after 6 weeks of in vitro fertilization treatment. A gynecological examination and color Doppler ultrasound scan revealed intra-uterine and cervical gestational sacs both containing live fetuses. A Foley catheter balloon was inserted into the cervical canal, inflated and fixed by a cerclage suture at the level of the external cervical os, followed by ligation of the descending cervical branches of the uterine arteries. Systemic methotrexate was applied. Three days after removal of the Foley catheter, an evacuation of the intra-uterine gestational sac was performed. Hemorrhage from the implantation site was controlled immediately and a pregnancy termination was successfully performed. The procedure was uneventful and our patient was discharged with a preserved uterus. Conclusions Conservative treatment of cervical pregnancy using a Foley catheter balloon is more efficacious if the Foley catheter balloon is attached in the correct position with a cerclage suture at the level of the external os, followed by ligation of the descending cervical branches of the uterine arteries, thereby exerting maximal pressure on the bleeding vessels.

  11. Endovascular Repair of Acute Symptomatic Pararenal Aortic Aneurysm With Three Chimney and One Periscope Graft for Complete Visceral Artery Revascularization

    International Nuclear Information System (INIS)

    Brechtel, Klaus; Ketelsen, Dominik; Endisch, Andrea; Heller, Stephan; Heuschmid, Martin; Stock, Ulrich A.; Kalender, Guenay

    2012-01-01

    PurposeTo describe a modified endovascular technique for complete revascularization of visceral and renal arteries in symptomatic pararenal aortic aneurysm (PRAA).TechniqueArterial access was surgically established in both common femoral arteries (CFAs) and the left subclavian artery (LSA). Revascularization of the left renal artery, the celiac trunk, and the superior mesenteric artery was performed through one single sheath via the LSA. Suitable covered stents were put in the aortic branches but not deployed. The right renal artery was accessed over the left CFA. Due to the longitudinal extension of the presented aneurysm two stent-grafts were introduced via the right CFA. After deploying the aortic stent-grafts, all covered stents in the side branches were deployed consecutively with a minimum overlap of 5 mm over the cranial and caudal stent-graft edges. Simultaneous ballooning was performed to fully expand all stent-grafts and warranty patency. Conclusion: This is the first report in the literature of chimney grafting in PRAA for complete revascularization of visceral and renal branches by using more than two covered stents introduced from one side through one single sheath. However this technique is modified, it should be used only in bailout situations when branched stent-grafts are not available and/or surgery is not suitable.

  12. Left ventricular mass regression is independent of gradient drop and effective orifice area after aortic valve replacement with a porcine bioprosthesis.

    Science.gov (United States)

    Sádaba, Justo Rafael; Herregods, Marie-Christine; Bogaert, Jan; Harringer, Wolfgang; Gerosa, Gino

    2012-11-01

    The question of whether left ventricular mass (LVM) regression following aortic valve replacement (AVR) is affected by the prosthesis indexed effective orifice area (IEOA) and transprosthetic gradient has not been fully elucidated. Data from a prospective, core-laboratory-reviewed echocardiography and magnetic resonance imaging (MRI) study was used to determine if the degree of LVM regression following AVR with two types of porcine bioprosthesis in patients suffering from predominant aortic valve stenosis (AS) was related to the prosthesis IEOA and transprosthetic gradient. Over a two-year period, 149 patients enrolled at eight centers received either an Epic or an Epic Supra aortic bioprosthesis (St. Jude Medical, MN, USA). Preoperative valve dysfunction was pure AS in 54 patients (36%) and mixed valve disease (primarily stenosis) in 95 patients (64%). LVM was determined preoperatively and at six months postoperatively, using MRI. The prosthesis IEOA and transprosthetic gradient were calculated at six months by means of echocardiography. Data were available for 111 patients at both enrolment and six months postoperatively. The LVM at enrolment and at follow up was 154.96 +/- 42.50 g and 114.83 +/- 29.20 g, respectively (p regression methods, showed LVM regression to be independent of the mean systolic pressure gradient, peak systolic pressure and prosthesis IEOA at six months (p = 0.53, 0.43, and 0.15, respectively). At six months after AVR with a porcine bioprosthesis to treat AS, there was a significant LVM regression that was independent of the prosthesis IEOA and the mean systolic pressure gradient and peak systolic pressure.

  13. Vertical sounding balloons for stratospheric photochemistry

    Science.gov (United States)

    Pommereau, J. P.

    The use of vertical sounding balloons for stratospheric photochemistry studies is illustrated by the use of a vertical piloted gas balloon for the search of NO2 diurnal variations. It is shown that the use of montgolfieres (hot air balloons) can enhance the vertical sounding technique. Particular attention is given to a sun-heated montgolfiere and to the more sophisticated infrared montgolfiere that is able to perform three to four vertical excursions per day and to remain aloft for weeks or months.

  14. Boston's balloon dilatation for treatment of cardiac achalasia

    International Nuclear Information System (INIS)

    Yin Jianguo; Song Jinwen; Yang Yan; Liu Xiaohong; Fu Zhiming; Zhang Yaqin

    2001-01-01

    Objective: To review and summarize effectiveness and method of the Boston's balloon dilation in cardiac achalasia. Methods: The intensified guide wire was inserted into stomach through mouth cavity under TV control. The Boston's balloon was inserted to the cardiac stricture through the guide wire and dilatated with 15% contrast medium with to a maximum diameter for five minutes and then the balloon was dilatated again for 3-5 minutes, all together for 3-4 times. The severe stricture must be pre-dilatated with 20-25 mm diameter balloon. Results: The balloon insertion was technically successful in all 26 patients. The once success of balloon dilation was achieved in 24 patients and twice in other 2. Follow-up time was from 2 weeks to 31 months (mean 10.6 months). Recurrent stenosis had not occurred in all patients. Remission rate of dysphagia was 100%. Esophageal reflux occurred in 3 patients. Conclusions: The Boston's balloon dilatation is simple and effective for treatment of cardiac achalasia. The method sometimes may replace surgical procedure

  15. Routine preoperative blood group and save testing is unnecessary for elective laparoscopic cholecystectomy

    International Nuclear Information System (INIS)

    Tandon, A.; Shahzad, K.; Nunes, Q.; Shrotri, M.; Lunevicius, R.

    2017-01-01

    Background: Although the practice of preoperative testing of ABO group and Rh (D) type for elective cholecystectomy has deep historical roots, it is not evidence-based. We aimed to assess the preoperative blood group and save testing practice for a cohort of patients subjected to elective laparoscopic cholecystectomy for symptomatic cholecystolithiasis between January 2010 and October 2014. Methods: National Health Service (NHS) hospital based, surgical procedure-specific, retrospective study was conducted. A final group consisted of 2,079 adult patients. We estimated the incidence of perioperative blood transfusion attributable to laparoscopic cholecystectomy. The results of eight other studies are presented. Results: A preoperative blood group and save test was performed in 907 patients (43.6%), whereas cross-matching was documented in 28 patients (3.1%). None required an intraoperative blood transfusion. Twelve patients (0.58%) underwent blood transfusion postoperatively following laparoscopic cholecystectomy, of which ten were transfused due to severe intra-abdominal bleeding (0.48%). There were no deaths. Conclusions: The likelihood of blood transfusion attributable to elective laparoscopic cholecystectomy is 1:200. A routine preoperative blood group and save testing is unnecessary. It neither alters the management of severe hypovolemia, secondary to perioperative bleeding, nor does it lead to better outcomes. (author)

  16. Clinical experience with the Monorail balloon catheter for coronary angioplasty.

    Science.gov (United States)

    Finci, L; Meier, B; Roy, P; Steffenino, G; Rutishauser, W

    1988-01-01

    The Monorail balloon catheter is distinctly different from other current balloon catheters: the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the guiding catheter. Monorail coronary angioplasty was attempted in 61 patients on 73 lesions with balloons from 2.0 to 3.7 mm. Angiographic success was obtained in 66 lesions (90%). For 15 lesions, balloon exchanges were needed. In three lesions, the Monorail balloon failed to cross the lesion, while a standard balloon succeeded; two lesions could not be crossed with any balloon. Vessel occlusion occurred in four patients: two had emergency surgery without infarct (one died suddenly 4 days later and one had a stroke 1 day later), one was recanalized with a standard balloon, and one had a myocardial infarct. Continuous infusion of urokinase was used until patient 3 in whom problems with the delivery system led to cardiocerebral air embolization (with complete recovery). No thrombotic complications were observed in the subsequent 58 patients with only a bolus of 10,000 U of heparin. The Monorail balloon facilitates contrast injections and balloon exchanges but appears more difficult to pass through tight lesions. Omission of the previously recommended infusion with a thrombolytic agent proved safe.

  17. Use of monorail PTCA balloon catheter for local drug delivery.

    Science.gov (United States)

    Trehan, Vijay; Nair, Girish M; Gupta, Mohit D

    2007-01-01

    We report the use of monorail coronary balloon as an infusion catheter to give bailout abciximab selectively into the site of stent thrombosis as an adjunct to plain old balloon angioplasty (POBA) in a patient of subacute stent thrombosis of the left anterior descending coronary artery. The balloon component (polyamide material) of the monorail balloon catheter was shaved off the catheter so that abciximab injected through the balloon port of the catheter exited out the shaft of the balloon catheter at the site from where the balloon material was shaved off. We believe that selective infusion with abciximab along with POBA established antegrade flow and relieved the patient's ischemia. In the absence of essential hardware to give intracoronary drugs in an emergency situation, one may employ our technique of infusion through a monorail balloon catheter after shaving the balloon component from the catheter.

  18. Reverse extra-anatomic aortic arch debranching procedure allowing thoracic endovascular aortic repair of a chronic ascending aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Ludovic Canaud, MD, PhD

    2018-06-01

    Full Text Available A 79-year-old woman was admitted with a large chronic dissecting ascending aortic aneurysm starting 5 mm distal to the ostia of the left coronary artery and ending immediately proximal to the innominate artery. A reverse extra-anatomic aortic arch debranching procedure was performed. During the same operative time, through a transapical approach, a thoracic stent graft was deployed with the proximal landing zone just distal to the coronary ostia and the distal landing zone excluding the origin of the left common carotid artery. The postoperative course was uneventful. Computed tomography at 12 months documented patent extra-anatomic aortic arch debranching and no evidence of endoleak. Keywords: Ascending aorta, Thoracic aorta, Aortic dissection, Stent graft

  19. Retrograde ascending aortic dissection during or after thoracic aortic stent graft placement: insight from the European registry on endovascular aortic repair complications

    DEFF Research Database (Denmark)

    Eggebrecht, Holger; Thompson, Matt; Rousseau, Hervé

    2009-01-01

    BACKGROUND: Single-center reports have identified retrograde ascending aortic dissection (rAAD) as a potentially lethal complication of thoracic endovascular aortic repair (TEVAR). METHODS AND RESULTS: Between 1995 and 2008, 28 centers participating in the European Registry on Endovascular Aortic...

  20. Navigation system for robot-assisted intra-articular lower-limb fracture surgery.

    Science.gov (United States)

    Dagnino, Giulio; Georgilas, Ioannis; Köhler, Paul; Morad, Samir; Atkins, Roger; Dogramadzi, Sanja

    2016-10-01

    In the surgical treatment for lower-leg intra-articular fractures, the fragments have to be positioned and aligned to reconstruct the fractured bone as precisely as possible, to allow the joint to function correctly again. Standard procedures use 2D radiographs to estimate the desired reduction position of bone fragments. However, optimal correction in a 3D space requires 3D imaging. This paper introduces a new navigation system that uses pre-operative planning based on 3D CT data and intra-operative 3D guidance to virtually reduce lower-limb intra-articular fractures. Physical reduction in the fractures is then performed by our robotic system based on the virtual reduction. 3D models of bone fragments are segmented from CT scan. Fragments are pre-operatively visualized on the screen and virtually manipulated by the surgeon through a dedicated GUI to achieve the virtual reduction in the fracture. Intra-operatively, the actual position of the bone fragments is provided by an optical tracker enabling real-time 3D guidance. The motion commands for the robot connected to the bone fragment are generated, and the fracture physically reduced based on the surgeon's virtual reduction. To test the system, four femur models were fractured to obtain four different distal femur fracture types. Each one of them was subsequently reduced 20 times by a surgeon using our system. The navigation system allowed an orthopaedic surgeon to virtually reduce the fracture with a maximum residual positioning error of [Formula: see text] (translational) and [Formula: see text] (rotational). Correspondent physical reductions resulted in an accuracy of 1.03 ± 0.2 mm and [Formula: see text], when the robot reduced the fracture. Experimental outcome demonstrates the accuracy and effectiveness of the proposed navigation system, presenting a fracture reduction accuracy of about 1 mm and [Formula: see text], and meeting the clinical requirements for distal femur fracture reduction procedures.

  1. FUNCTIONAL OUTCOME OF INTERNAL FIXATION FOR DISPLACED INTRA-ARTICULAR CALCANEAL FRACTURE

    Directory of Open Access Journals (Sweden)

    Saket Jati

    2016-12-01

    Full Text Available BACKGROUND There are always difference of opinion in the importance of Bohler’s angle in evaluating the severity of displaced intra-articular calcaneal fractures and predicting the functional outcome following surgical fixation. The purpose of this research, the relationship exists between Bohler’s angle and the injury severity of displaced calcaneal fractures and between surgical improvement of Bohler’s angle and its practical outcome. MATERIALS AND METHODS Patients were treated surgically for unilateral closed displaced intra-articular calcaneal fractures from May 2014 to October 2016 were identified. The Bohler’s angles of bilateral calcaneus were measured and was compared to the dimension of the uninjured foot was used as its normal control. The difference in the value of Bohler’s angle measured preoperatively or after surgery between the angle of the damaged foot and that of the contralateral calcaneus was calculated, respectively. The change in Bohler’s angle by ratio was calculated by dividing the variation in the value of Bohler’s angle between bilateral calcaneus by its typical control. The injury severity was assessed according to Sanders classification. The functional outcomes were assessed using American Orthopaedic Foot and Ankle Society hindfoot scores. RESULTS 30 patients were included into the study with a mean follow-up duration of 30 months. According to Sanders classification, the fracture pattern included 12 type II, 10 type III and 8 type IV fractures. According to American Orthopaedic Foot and Ankle Society hindfoot scoring system, the excellent, good, fair and poor results were achieved in 10, 8, 4 and 2 patients, respectively. The preoperative Bohler’s angle, difference value of Bohler’s angle between bilateral calcaneus and change in Bohler’s angle by ratio each has a significant relationship with Sanders classification (P=0.003; P=0.004; P=0.005, respectively, however, is not correlated with

  2. Intra-operative Ultrasound as a Tool to Assess Free Borders of Primary Vascular Aortic Tumors During Resection

    Directory of Open Access Journals (Sweden)

    R.M. Andersen

    Full Text Available : Introduction: Primary vascular tumors are rare and, in general, have a poor prognosis. Complete resection is associated with a better prognosis. Radical resection depends on safe discrimination of tumor borders. Technical summary: A 54 year old woman presented with abdominal pain. Imaging revealed a mass in the thoracic aorta, highly suspicious of angiosarcoma which was confirmed post-operatively by histological analysis. Open surgery was performed. Prior to clamping of the aorta, intra-operative ultrasound established clear delineation of the tumor borders. Conclusion: Intra-operative ultrasound was, in this case, a safe and easy method to determine the tumor borders, providing a simple guide to in toto tumor removal. Keywords: Angiosarcoma, Intra-operative ultrasound, In toto tumor removal, Fludeoxyglucose positron emission tomography/computed tomography, Magnetic resonance imaging

  3. A system for visualization and automatic placement of the endoclamp balloon catheter

    Science.gov (United States)

    Furtado, Hugo; Stüdeli, Thomas; Sette, Mauro; Samset, Eigil; Gersak, Borut

    2010-02-01

    The European research network "Augmented Reality in Surgery" (ARIS*ER) developed a system that supports minimally invasive cardiac surgery based on augmented reality (AR) technology. The system supports the surgical team during aortic endoclamping where a balloon catheter has to be positioned and kept in place within the aorta. The presented system addresses the two biggest difficulties of the task: lack of visualization and difficulty in maneuvering the catheter. The system was developed using a user centered design methodology with medical doctors, engineers and human factor specialists equally involved in all the development steps. The system was implemented using the AR framework "Studierstube" developed at TU Graz and can be used to visualize in real-time the position of the balloon catheter inside the aorta. The spatial position of the catheter is measured by a magnetic tracking system and superimposed on a 3D model of the patient's thorax. The alignment is made with a rigid registration algorithm. Together with a user defined target, the spatial position data drives an actuator which adjusts the position of the catheter in the initial placement and corrects migrations during the surgery. Two user studies with a silicon phantom show promising results regarding usefulness of the system: the users perform the placement tasks faster and more accurately than with the current restricted visual support. Animal studies also provided a first indication that the system brings additional value in the real clinical setting. This work represents a major step towards safer and simpler minimally invasive cardiac surgery.

  4. Structure variations of pumpkin balloon

    Science.gov (United States)

    Yajima, N.; Izutsu, N.; Honda, H.

    2004-01-01

    A lobed pumpkin balloon by 3-D gore design concept is recognized as a basic form for a super-pressure balloon. This paper deals with extensions of this design concept for other large pressurized membrane structures, such as a stratospheric airship and a balloon of which volume is controllable. The structural modifications are performed by means of additional ropes, belts or a strut. When the original pumpkin shape is modified by these systems, the superior characteristics of the 3-D gore design, incorporating large bulges with a small local radius and unidirectional film tension, should be maintained. Improved design methods which are adequate for the above subjects will be discussed in detail. Application for ground structures are also mentioned.

  5. Development of a Super-Pressure Balloon with an Improved Design

    Science.gov (United States)

    Izutsu, Naoki; Akita, Daisuke; Fuke, Hideyuki; Iijima, Issei; Kato, Yoichi; Kawada, Jiro; Matsushima, Kiyoho; Matsuzaka, Yukihiko; Mizuta, Eiichi; Nakada, Takashi; Nonaka, Naoki; Saito, Yoshitaka; Takada, Atsushi; Tamura, Keisuke; Yamada, Kazuhiko; Yoshida, Tetsuya

    A zero-pressure balloon used for scientific observation in the stratosphere has an unmanageable limitation that its floating altitude decreases during a nighttime because of temperature drop of the lifting gas. Since a super-pressure balloon may not change its volume, the lifetime can extend very long. We had introduced so called the ‘lobed-pumpkin’ type of super-pressure balloon that can realize a full-scale long-duration balloon and it will be in practical use in the very near future. As for larger super-pressure balloons, however, we still have some potential difficulties to be resolved. We here propose a new design suitable for a larger super-pressure balloon, which is roughly ‘lobed pumpkin with lobed cylinder’ and can adapt a single design for balloons of a wide range of volumes. Indoor inflation tests were successfully carried out with balloons designed and made by the method. It has been shown that the limit of the resisting pressure differential for a new designed balloon is same as that of a normal lobed-pumpkin balloon.

  6. Understanding the C-pulse device and its potential to treat heart failure.

    Science.gov (United States)

    Sales, Virna L; McCarthy, Patrick M

    2010-03-01

    The Sunshine Heart C-Pulse (C-Pulse; Sunshine Heart Inc., Tustin, CA) device is an extra-aortic implantable counterpulsation pump designed as a non-blood contacting ambulatory heart assist device, which may provide relief from symptoms for class II-III congestive heart failure patients. It has a comparable hemodynamic augmentation to intra-aortic balloon counterpulsation devices. The C-Pulse cuff is implanted through a median sternotomy, secured around the ascending aorta, and pneumatically driven by an external system controller. Pre-clinical studies in the acute pig model, and initial temporary clinical studies in patients undergoing off-pump coronary bypass surgery have shown substantial increase in diastolic perfusion of the coronary vessels, which translated to a favorable improvement in ventricular function. A U.S. prospective multi-center trial to evaluate the safety and efficacy of the C-Pulse in class III patients with moderate heart failure is now in progress.

  7. Ballooning behavior in the golden orbweb spider Nephilapilipes (Araneae: Nephilidae

    Directory of Open Access Journals (Sweden)

    Vanessa M.J. Lee

    2015-01-01

    Full Text Available Ballooning, a mode of aerial dispersal in spiders, is an innate behavior that requires appropriate physiological and meteorological conditions. Although only rarely reported in the golden orbweb spiders, family Nephilidae, the large geographic distributions of most nephilids—in particular of Nephila species—would imply that these spiders likely routinely disperse by ballooning in spite of giant female sizes. Here we study ballooning behavior in the golden orbweb spider Nephila pilipes (Fabricius, 1793. Specifically, we test for the propensity of spiderlings to deploy ballooning as a dispersal mechanism. We subjected a total of 59 first-instar spiderlings to a wind experiment at two wind speeds (2.17 ± 0.02 m s-1 and 3.17 ± 0.02 m s-1 under laboratory conditions. Under an average wind speed of 3.17 m s-1, none of the spiderlings exhibited pre-ballooning or ballooning behavior. However, at an average wind speed of 2.17 m s-1, 53 (89.8% spiderlings showed pre-ballooning behavior, and 17 (32.1% of the pre-ballooners ultimately ballooned. Our results concur with prior reports on spiderlings of other families that pre-ballooning behavior is a requirement for ballooning to occur. Furthermore, although we cannot rule out other dispersal mechanisms such as synanthropic spread, our findings suggest that the widespread N. pilipes uses ballooning to colonize remote oceanic islands.

  8. Balloon sacroplasty as a palliative pain treatment in patients with metastasis-induced bone destruction and pathological fractures

    Energy Technology Data Exchange (ETDEWEB)

    Andresen, R.; Luedtke, C.W.; Kamusella, P.; Wissgott, C. [Westkuestenklinikum Heide, Academic Teaching Hospital of the Universities of Kiel, Luebeck and Hamburg, Heide (Germany). Inst. of Diagnostic and Interventional Radiology/Neuroradiology; Radmer, S. [Center of Orthopedics, Berlin (Germany). Orthopedic Surgery and Traumatology; Schober, H.C. [Municipal Hospital Suedstadt Rostock, Academic Teaching Hospital of the University of Rostock (Germany). Dept. of Internal Medicine

    2014-09-15

    Purpose: In the case of metastatic involvement of the sacrum with destruction and consecutive pathological fracture, intense disabling pain is one of the defining factors. The feasibility, safety and pain development with cement augmentation were to be investigated. Materials and Methods: CT-guided balloon sacroplasty was conducted in 10 patients with metastasis-induced bone destruction of the sacrum. After establishment of the entry point, a K-wire was first introduced as far as the central tumor lesion via the short, or transiliac axis. A cannula was then positioned over the wire. Under CT guidance, a balloon catheter was introduced through the cannula and inflated and deflated several times. The PMMA cement was then injected into the preformed cavity. The procedure was completed by a spiral CT control using the thin-slice technique. Pain intensity was determined using a visual analog scale (VAS) before the procedure, on the 2nd postoperative day and 6 months after the intervention. Finally, the patients were asked to state how satisfied they were. Results: Balloon sacroplasty was technically feasible in all patients. The control CT scan showed central distribution of the cement in the tumor lesion. On average 6+/-1.78 (4-10) ml of PMMA cement were introduced per treated lesion. A significant (p < 0.001) reduction in pain according to the VAS occurred in all patients from 9.3+/-0.67 (8-10) pre-operatively to 2.7+/-1.28 (1-5) on the 2nd postoperative day and 2.9+/-0.81 (2-5) 6 months after the intervention. All of the patients were re-mobilized after the procedure and underwent the further therapeutic measures as planned. Conclusion: Balloon sacroplasty is a helpful therapeutic option in the overall palliative treatment of patients with tumor-induced destruction. It is a safe and practicable procedure that markedly reduces disabling pain. (orig.)

  9. Balloon sacroplasty as a palliative pain treatment in patients with metastasis-induced bone destruction and pathological fractures

    International Nuclear Information System (INIS)

    Andresen, R.; Luedtke, C.W.; Kamusella, P.; Wissgott, C.; Radmer, S.; Schober, H.C.

    2014-01-01

    Purpose: In the case of metastatic involvement of the sacrum with destruction and consecutive pathological fracture, intense disabling pain is one of the defining factors. The feasibility, safety and pain development with cement augmentation were to be investigated. Materials and Methods: CT-guided balloon sacroplasty was conducted in 10 patients with metastasis-induced bone destruction of the sacrum. After establishment of the entry point, a K-wire was first introduced as far as the central tumor lesion via the short, or transiliac axis. A cannula was then positioned over the wire. Under CT guidance, a balloon catheter was introduced through the cannula and inflated and deflated several times. The PMMA cement was then injected into the preformed cavity. The procedure was completed by a spiral CT control using the thin-slice technique. Pain intensity was determined using a visual analog scale (VAS) before the procedure, on the 2nd postoperative day and 6 months after the intervention. Finally, the patients were asked to state how satisfied they were. Results: Balloon sacroplasty was technically feasible in all patients. The control CT scan showed central distribution of the cement in the tumor lesion. On average 6+/-1.78 (4-10) ml of PMMA cement were introduced per treated lesion. A significant (p < 0.001) reduction in pain according to the VAS occurred in all patients from 9.3+/-0.67 (8-10) pre-operatively to 2.7+/-1.28 (1-5) on the 2nd postoperative day and 2.9+/-0.81 (2-5) 6 months after the intervention. All of the patients were re-mobilized after the procedure and underwent the further therapeutic measures as planned. Conclusion: Balloon sacroplasty is a helpful therapeutic option in the overall palliative treatment of patients with tumor-induced destruction. It is a safe and practicable procedure that markedly reduces disabling pain. (orig.)

  10. Geometric Deformations of the Thoracic Aorta and Supra-Aortic Arch Branch Vessels Following Thoracic Endovascular Aortic Repair.

    Science.gov (United States)

    Ullery, Brant W; Suh, Ga-Young; Hirotsu, Kelsey; Zhu, David; Lee, Jason T; Dake, Michael D; Fleischmann, Dominik; Cheng, Christopher P

    2018-04-01

    To utilize 3-D modeling techniques to better characterize geometric deformations of the supra-aortic arch branch vessels and descending thoracic aorta after thoracic endovascular aortic repair. Eighteen patients underwent endovascular repair of either type B aortic dissection (n = 10) or thoracic aortic aneurysm (n = 8). Computed tomography angiography was obtained pre- and postprocedure, and 3-D geometric models of the aorta and supra-aortic branch vessels were constructed. Branch angle of the supra-aortic branch vessels and curvature metrics of the ascending aorta, aortic arch, and stented thoracic aortic lumen were calculated both at pre- and postintervention. The left common carotid artery branch angle was lower than the left subclavian artery angles preintervention ( P Supra-aortic branch vessel angulation remains relatively static when proximal landing zones are distal to the left common carotid artery.

  11. Aortic obstruction: anatomy and echocardiography

    Directory of Open Access Journals (Sweden)

    Keirns Candace

    2006-09-01

    Full Text Available Abstract Echocardiography is a valuable non-invasive technique for identifying the site and type of aortic obstruction. Knowledge of the morphological details of each type of obstruction is the basis for correct interpretation of the diagnostic images and clinical decisions. This study was undertaken to correlate the echocardiographic images with anatomic specimens of equivalent valvular and supravalvular aortic obstruction. Specimens were part of the collection of the Department of Embryology. Fifty six patients were studied, and forty specimens with aortic obstruction were analyzed. Echocardiographic characteristics: Thirty one (55.3% patients were women and twenty five (44.7% men. Valvular aortic obstruction was found in Thirty six patients (64.3 % and supravalvular aortic obstruction in twenty (35.7%. Anatomic characteristics: Of the forty specimens examined, twenty one (52.5% had valvular aortic obstruction and nineteen (47.5% supravalvular aortic obstruction. The anatomoechocardiographic correlation clearly showed that the anatomic findings of the specimen hearts and aortas corresponded to echocardiographic images of valvular and supravalvular aortic obstruction and provided solid corroboration of echocardiographic diagnoses.

  12. Prosthesis-patient mismatch in bovine pericardial aortic valves: evaluation using 3 different modalities and associated medium-term outcomes.

    Science.gov (United States)

    Chacko, Satish Jacob; Ansari, Asimul H; McCarthy, Patrick M; Malaisrie, S Chris; Andrei, Adin-Cristian; Li, Zhi; Lee, Richard; McGee, Edwin; Bonow, Robert O; Puthumana, Jyothy J

    2013-09-01

    The prevalence of prosthesis-patient mismatch (PPM) and its impact on survival after aortic valve replacement have not been clearly defined. Historically, the presence of PPM was identified from postoperative echocardiograms or preoperative manufacturer-provided charts, resulting in wide discrepancies. The 2009 American Society of Echocardiography (ASE) guidelines proposed an algorithmic approach to calculate PPM. This study compared PPM prevalence and its impact on survival using 3 modalities: (1) the ASE guidelines-suggested algorithm (ASE PPM); (2) the manufacturer-provided charts (M PPM); and (3) the echocardiographically measured, body surface area-indexed, effective orifice area (EOAi PPM) measurement. A total of 614 patients underwent aortic valve replacement with bovine pericardial valves from 2004 to 2009 and had normal preoperative systolic function. EOAi PPM was severe if EOAi was ≤ 0.60 cm(2)/m(2), moderate if EOAi was 0.60 to 0.85 cm(2)/m(2), and absent (none) if EOAi was ≥ 0.85 cm(2)/m(2). ASE PPM was severe in 22 (3.6%), moderate in 6 (1%), and absent (none) in 586 (95.4%). ASE PPM was similar to manufacturer-provided PPM (P=1.00). ASE PPM differed significantly from EOAi PPM (P<0.001), which identified severe mismatch in 170 (29.7%), moderate in 191 (33.4%), and absent (none) in 211 patients (36.9%). Irrespective of the PPM classification method, PPM did not adversely affect midterm survival (average follow-up, 4.1 ± 1.8 years; median, 3.9 years; range, 0.01-8 years). There were no reoperations for PPM. In patients with normal systolic function undergoing bovine pericardial aortic valve replacement, the prevalence of PPM using the algorithmic-ASE approach was low and correlated well with manufacturer-provided PPM. Independent of the method of PPM assessment, PPM was not associated with medium-term mortality.

  13. Optimizing logistics for balloon-occluded retrograde transvenous obliteration (BRTO) of gastric varices by doing away with the indwelling balloon: concept and techniques.

    Science.gov (United States)

    Saad, Wael E; Nicholson, David B

    2013-06-01

    Since the conception of balloon-occluded retrograde transvenous obliteration (BRTO) of gastric varices 25 years ago, the placement of an indwelling balloon for hours has been central to the BRTO procedure. Numerous variables and variations of the BRTO procedure have been described, including methods to reduce sclerosant, combining percutaneous transhepatic obliteration, varying sclerosant, and using multiple sclerosants within the same procedure. However, the consistent feature of BRTO has always remained the indwelling balloon. Placing an indwelling balloon over hours for the BRTO procedure is a logistical burden that taxes the interventional radiology team and hospital resources. Substituting the balloon with hardware (coils or Amplatzer vascular plugs [AVPs] or both) is technically feasible and its risks most likely correlate with gastrorenal shunt (GRS) size. The current authors use packed 0.018- or 0.035-in coils or both for small gastric variceal systems (GRS size A and B) and AVPs for GRS sizes up to size E (from size A-E). The current authors recommend an indwelling balloon (no hardware substitute) for very large gastric variceal system (GRS size F). Substituting the indwelling balloon for hardware in size F and potentially size E GRS can also be risky. The current article describes the techniques of placing up to 16-mm AVPs through balloon occlusion guide catheters and then deflating the balloon once it has been substituted with the AVPs. In addition, 22-mm AVPs can be placed through sheaths once the balloon occlusion catheters are removed to further augment the 16-mm Amplatzer occlusion. To date, there are no studies describing, let alone evaluating, the clinical feasibility of performing BRTO without indwelling balloons. The described techniques have been successfully performed by the current authors. However, the long-term safety and effectiveness of these techniques is yet to be determined. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Primary balloon angioplasty for symptomatic, high-grade intracranial stenosis.

    Science.gov (United States)

    Tomycz, Luke; Bansal, Neil K; Lockney, Tim; Strothers, Megan; Connors, John J; Shay, Scott; Singer, Robert J

    2013-01-01

    In light of recent controversy about the safety and efficacy of intracranial stenting, we sought to evaluate our experience with primary balloon angioplasty for symptomatic, high-grade intracranial stenosis. All intracranial angioplasty cases performed at Vanderbilt University Medical Center from 2006 to 2011 were retrospectively reviewed for degree of stenosis pre- and post-procedure. Immediate peri-procedural complications were evaluated as well as one-month and long-term outcomes. A total of 26 patients were included in the study with a mean age of 63.0 years and a mean follow-up of 350.2 days. The average pre-procedure stenosis was 71.2%. The immediate, average post-procedure stenosis was 46.6%, and the average post-procedure stenosis at last angiographic follow-up was 44.5%. Retreatment was required in only 3.8% of patients. The primary end-point of major stroke or death at 30 days was observed in 11.5%, and the overall intra-procedural complication rate was 7.7%. The incidence of stroke or death at last follow-up was 15.4%, which is comparable to the one-year stroke or death rate in the medical arm of the SAMPRISS trial. In this retrospective series, primary balloon angioplasty was found to be effective as a treatment option for symptomatic intracranial stenosis with the risk of stroke or death at 30 days higher than the medical arm of SAMPRIS but lower than the stenting arm. The one-year risk of stroke was comparable to that reported for the one-year outcomes in the SAMPRISS medical arm.

  15. Unusual Case of Overt Aortic Dissection Mimicking Aortic Intramural Hematoma

    Directory of Open Access Journals (Sweden)

    Kushtrim Disha

    2016-04-01

    Full Text Available We report an interesting case in which overt aortic dissection mimicked two episodes of aortic intramural hematoma (IMH (Stanford A, DeBakey I. This took place over the course of four days and had a major influence on the surgical treatment strategy. The first episode of IMH regressed completely within 15 hours after it was clinically diagnosed and verified using imaging techniques. The recurrence of IMH was detected three days thereafter, resulting in an urgent surgical intervention. Overt aortic dissection with evidence of an intimal tear was diagnosed intraoperatively.

  16. Influence of type of aortic valve prosthesis on coronary blood flow velocity.

    Science.gov (United States)

    Jelenc, Matija; Juvan, Katja Ažman; Medvešček, Nadja Tatjana Ružič; Geršak, Borut

    2013-02-01

    Severe aortic valve stenosis is associated with high resting and reduced hyperemic coronary blood flow. Coronary blood flow increases after aortic valve replacement (AVR); however, the increase depends on the type of prosthesis used. The present study investigates the influence of type of aortic valve prosthesis on coronary blood flow velocity. The blood flow velocity in the left anterior descending coronary artery (LAD) and the right coronary artery (RCA) was measured intraoperatively before and after AVR with a stentless bioprosthesis (Sorin Freedom Solo; n = 11) or a bileaflet mechanical prosthesis (St. Jude Medical Regent; n = 11). Measurements were made with an X-Plore epicardial Doppler probe (Medistim, Oslo, Norway) following induction of hyperemia with an adenosine infusion. Preoperative and postoperative echocardiography evaluations were used to assess valvular and ventricular function. Velocity time integrals (VTI) were measured from the Doppler signals and used to calculate the proportion of systolic VTI (SF), diastolic VTI (DF), and normalized systolic coronary blood flow velocities (NSF) and normalized diastolic coronary blood flow velocities (NDF). The systolic proportion of the LAD VTI increased after AVR with the St. Jude Medical Regent prosthesis, which produced higher LAD SF and NSF values than the Sorin Freedom Solo prosthesis (SF, 0.41 ± 0.09 versus 0.29 ± 0.13 [P = .04]; NSF, 0.88 ± 0.24 versus 0.55 ± 0.17 [P = .01]). No significant changes in the LAD velocity profile were noted after valve replacement with the Sorin Freedom Solo, despite a significant reduction in transvalvular gradient and an increase in the effective orifice area. AVR had no effect on the RCA flow velocity profile. The coronary flow velocity profile in the LAD was significantly influenced by the type of aortic valve prosthesis used. The differences in the LAD velocity profile probably reflect differences in valve design and the systolic transvalvular flow pattern.

  17. Supra-aortic interventions for endovascular exclusion of the entire aortic arch.

    Science.gov (United States)

    Andrási, Terézia B; Grossmann, Marius; Zenker, Dieter; Danner, Bernhard C; Schöndube, Friedrich A

    2017-07-01

    Our aim was to analyze the outcomes of endovascular exclusion of the entire aortic arch (proximal landing in zone 0, distal landing in zone III or beyond, after Ishimaru) in which complete surgical debranching of the supra-aortic vessels (I), endovascular supra-aortic revascularization (chimney, fenestrated, or branched grafts) with partial surgical debranching (II), or total endovascular supra-aortic revascularization (III) was additionally performed. Publications describing endovascular repair of the aortic arch (2000-2016) were systematically searched and reviewed. From a total of 53 relevant studies including 1853 patients, only 1021 patients undergoing 35 different total aortic arch procedures were found eligible for further evaluation and included in group I, II, or III (429, 190, and 402 patients, respectively). Overall early mortality was higher in group I vs groups II and III (P = .001; 1 - β = 95.6%) but exceeded in group III (18.6%) and group II (14.0%) vs group I (8.0%; P = .044; 1 - β = 57.4%) for diseases involving zone 0. Mortality was higher in all subgroups treated for zone 0 disease compared with corresponding subgroups treated for zone I to zone III disease. The incidence of cerebral ischemic events was increased in groups I and II vs group III (7.5% and 11% vs 1.7%; P = .0001) and correlated with early mortality (R 2  = .20; P = .033). The incidence of type II endoleaks and endovascular reintervention was similar between groups and correlated with each other (R 2  = .37; P = .004). Type Ia endoleak occurred more often in groups II and III than in group I (7.1% and 12.1% vs 5.8%; P = .023) and correlated with midterm mortality (R 2  = .53; P = .005). Retrograde type A dissection was low in all groups, whereas aneurysm growth was higher in group III (2.6%, 4.2%, 10.7%; P = .002), correlating with midterm mortality (R 2  = .311; P = .009). Surgical revision slightly correlated with surgical complications (R 2  = .18; P = .044

  18. Aorto-right atrial fistula after ascending aortic replacement or aortic value replacement

    International Nuclear Information System (INIS)

    Zhi Aihua; Dai Ruping; Jiang Shiliang; Lu Bin

    2012-01-01

    Objective: To evaluate the CT features of aorto-right atrial fistula after aortic valve replacement (AVR) or ascending aortic replacement. Methods: Eighty-seven patients with aortic-right atrial fistula underwent CT after operation. The CT features were retrospectively analyzed. Fistula was measured according to maximum width of the shunt. Results: Aorto-right atrial fistula was detected in 87 patients after aortic valve replacement or ascending aortic replacement by CT scan. Among them, 25 patients were diagnosed as mild aorto-right atrial fistula, 47 patients as moderate, and 15 patients as severe. Thirty-seven patients underwent follow-up CT.Among them, 10 patients with mild to moderate aorto-right atrial fistula were considered to have complete regression, 8 patients with mild aorto-right atrial fistula considered to have incomplete regression, 14 patients with mild to moderate aorto-right atrial fistula considered to have stable condition, and 5 patients with moderate aorto-right atrial fistula considered to have progression at the 3-month follow-up. Conclusion: CT is a useful tool for defining aorto-right atrial fistula after AVR or ascending aortic replacement and for evaluating it in follow-up. (authors)

  19. Traumatic Aortic Injury

    Directory of Open Access Journals (Sweden)

    Brianna Miner

    2016-09-01

    Full Text Available History of present illness: A 48-year-old male with unknown past medical history presents as a trauma after being hit by a car traveling approximately 25 miles per hour. On initial presentation, the patient is confused, combative, and not answering questions appropriately. The patient is hypotensive with a blood pressure of 68/40 and a heart rate of 50 beats per minute, with oxygen saturation at 96% on room air. FAST scan is positive for fluid in Morrison’s pouch, splenorenal space, and pericardial space. Significant findings: The initial chest x-ray showed an abnormal superior mediastinal contour (blue line, suggestive of a possible aortic injury. The CT angiogram showed extensive circumferential irregularity and outpouching of the distal aortic arch (red arrows compatible with aortic transection. In addition, there was a circumferential intramural hematoma, which extended through the descending aorta to the proximal infrarenal abdominal aorta (green arrow. There was also an extensive surrounding mediastinal hematoma extending around the descending aorta and supraaortic branches (purple arrows. Discussion: Traumatic aortic injury is a life-threatening event. The incidence of blunt thoracic aortic injury is low, between 1 to 2 percent of those patients with blunt thoracic trauma.1 However, approximately 80% of patients with traumatic aortic injury die at the scene.2 Therefore it is imperative to diagnose traumatic aortic injury in a timely fashion. The diagnosis can be difficult due to the non-specific signs and symptoms and other distracting injuries. Clinical suspicion should be based on the mechanism of the injury and the hemodynamic status of the patient. In any patient with blunt or penetrating trauma to the chest that is hemodynamically unstable, traumatic aortic injury should be on the differential. Chest x-ray can be used as a screening tool. A normal chest x-ray has a negative predictive value of approximately 97%. CTA chest is the

  20. 21 CFR 884.5050 - Metreurynter-balloon abortion system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Metreurynter-balloon abortion system. 884.5050... Devices § 884.5050 Metreurynter-balloon abortion system. (a) Identification. A metreurynter-balloon abortion system is a device used to induce abortion. The device is inserted into the uterine cavity...