WorldWideScience

Sample records for preoperative computed axial

  1. Preoperative lymph-node staging of invasive urothelial bladder cancer with 18F-fluorodeoxyglucose positron emission tomography/computed axial tomography and magnetic resonance imaging

    DEFF Research Database (Denmark)

    Jensen, Thor Knak; Holt, Per; Gerke, Oke

    2011-01-01

    OBJECTIVE: The treatment and prognosis of bladder cancer are based on the depth of primary tumour invasion and the presence of metastases. A highly accurate preoperative tumour, node, metastasis (TNM) staging is critical to proper patient management and treatment. This study retrospectively...... investigated the value of ¹⁸F-fluorodeoxyglucose (FDG) positron emission tomography/computed axial tomography (¹⁸F-FDG PET/CT) and magnetic resonance imaging (MRI) for preoperative N staging of bladder cancer. Material and methods. From June 2006 to January 2008, 48 consecutive patients diagnosed with bladder......) for MRI and ¹⁸F-FDG PET/CT, respectively. The differences in specificity and negative predictive values were not statistically significant. Conclusions. No significant statistical difference between ¹⁸F-FDG PET/CT and MRI for preoperative N staging of urothelial bladder cancer was found in the study...

  2. Computational analysis of a multistage axial compressor

    Science.gov (United States)

    Mamidoju, Chaithanya

    Turbomachines are used extensively in Aerospace, Power Generation, and Oil & Gas Industries. Efficiency of these machines is often an important factor and has led to the continuous effort to improve the design to achieve better efficiency. The axial flow compressor is a major component in a gas turbine with the turbine's overall performance depending strongly on compressor performance. Traditional analysis of axial compressors involves throughflow calculations, isolated blade passage analysis, Quasi-3D blade-to-blade analysis, single-stage (rotor-stator) analysis, and multi-stage analysis involving larger design cycles. In the current study, the detailed flow through a 15 stage axial compressor is analyzed using a 3-D Navier Stokes CFD solver in a parallel computing environment. Methodology is described for steady state (frozen rotor stator) analysis of one blade passage per component. Various effects such as mesh type and density, boundary conditions, tip clearance and numerical issues such as turbulence model choice, advection model choice, and parallel processing performance are analyzed. A high sensitivity of the predictions to the above was found. Physical explanation to the flow features observed in the computational study are given. The total pressure rise verses mass flow rate was computed.

  3. The application of preoperative computed tomography angiogram for hemispherectomy

    Directory of Open Access Journals (Sweden)

    Jiqing Qiu

    2017-10-01

    Full Text Available Hemispherectomy is an established neurosurgical procedure for unilateral refractory epilepsy . Even though the surgical approach has evolved greatly, prevention of catastrophic intraoperative bleeding is a challenge. It is important that surgeons know the abnormal blood vessel before surgery. Herein, we report our experience with two patients in whom computed tomographic angiography (CTA was used in the preoperative evaluation for hemispherectomy. CTA allowed for precise anatomical delineation of the hemispheric vascular abnormalities. Preoperative CTA showed that the specific cerebral arteries and their branches ipsilateral to the lesion were slender. Elaborate preoperative planning for the surgical approach helped prevent catastrophic intraoperative bleeding. Favorable outcomes were achieved in both children. CTA appears to confer a considerable advantage in the preoperative vascular and anatomical delineation in patients scheduled for hemispherectomy. To our knowledge, this is the first report about the application of CTA for hemispherectomy preoperative planning.

  4. The accuracy of axial length measurements in cases of macula-off retinal detachment.

    Science.gov (United States)

    Abou-Shousha, Mohsen; Helaly, Hany Ahmed; Osman, Ihab Mohamed

    2016-04-01

    To assess the accuracy of axial length measurements in cases of macula-off retinal detachment using different methods (optical biometry, A-scan ultrasound, and combined applanation vector-A/B-scan biometry). This prospective clinical study included 100 eyes of 100 patients who underwent vitrectomy alone or phacovitrectomy for macula-off retinal detachment. All patients included signed an informed consent. Preoperative examination of the patients included recording the axial length measurements using optical biometry, A-scan ultrasound, and combined applanation vector-A/B-scan biometry. The mean postoperative IOLMaster axial length after macular reattachment was 26.11 ± 2.91 mm. The mean preoperative IOLMaster axial length with macula-off was 25.32 ± 2.72 mm. The mean preoperative A-scan axial length with macula-off was 25.29 ± 2.80 mm. The mean preoperative vector-A/B-scan axial length with macula-off was 26.03 ± 2.90 mm. The preoperative vector-A/B-scan mean absolute error was 0.59 ± 0.48 D (range, 0.10-2.25 D). Regular methods (optical biometry and A-scan biometry) of measuring the axial length in cases with a detached macula proved to be variable and less accurate. The vector-A/B-scan offered good measurements of the actual axial length in the patients. This was reflected on more accurate postoperative refractive outcome. Copyright © 2016 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  5. Multidetector computed tomography in the preoperative staging of gastric adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Ricardo Hoelz de Oliveira; Penachim, Thiago Jose; Martins, Daniel Lahan; Andreollo, Nelson Adami; Caserta, Nelson Marcio Gomes, E-mail: rhobarros@hotmail.com [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil)

    2015-03-15

    Objective: To evaluate the role of multidetector computed tomography in the preoperative investigation of tumor invasion depth and lymph node and metastatic involvement according to the TNM classification, in patients with gastric adenocarcinoma. Materials and Methods: Fifty-four patients with biopsy-confirmed gastric cancer underwent preoperative staging with 64-channel multidetector computed tomography. Two independent radiologists analyzed the images and classified the findings. Sensitivity, specificity, accuracy and overall accuracy were calculated for each observer. The interobserver agreement was also evaluated. Results: The accuracy in the classification of categories T ranged from 74% to 96% for observer 1 and from 80% to 92% for observer 2. The overall accuracy was 70% for both observers. The weighted kappa index was 0.75, consistent with a significant interobserver agreement. The accuracy in the classification of lymph node involvement (category N) ranged from 55% to 79% for observer 1 and from 73% to 82% for observer 2. The evaluation of metastatic involvement showed an overall accuracy of 89.6% for both observers. Conclusion: 64-channel multidetector computed tomography demonstrated clinically relevant accuracy in the preoperative staging of gastric adenocarcinoma as regards invasion depth (T category) and metastatic involvement (M category). (author)

  6. Multidetector computed tomography in the preoperative staging of gastric adenocarcinoma

    International Nuclear Information System (INIS)

    Barros, Ricardo Hoelz de Oliveira; Penachim, Thiago Jose; Martins, Daniel Lahan; Andreollo, Nelson Adami; Caserta, Nelson Marcio Gomes

    2015-01-01

    Objective: To evaluate the role of multidetector computed tomography in the preoperative investigation of tumor invasion depth and lymph node and metastatic involvement according to the TNM classification, in patients with gastric adenocarcinoma. Materials and Methods: Fifty-four patients with biopsy-confirmed gastric cancer underwent preoperative staging with 64-channel multidetector computed tomography. Two independent radiologists analyzed the images and classified the findings. Sensitivity, specificity, accuracy and overall accuracy were calculated for each observer. The interobserver agreement was also evaluated. Results: The accuracy in the classification of categories T ranged from 74% to 96% for observer 1 and from 80% to 92% for observer 2. The overall accuracy was 70% for both observers. The weighted kappa index was 0.75, consistent with a significant interobserver agreement. The accuracy in the classification of lymph node involvement (category N) ranged from 55% to 79% for observer 1 and from 73% to 82% for observer 2. The evaluation of metastatic involvement showed an overall accuracy of 89.6% for both observers. Conclusion: 64-channel multidetector computed tomography demonstrated clinically relevant accuracy in the preoperative staging of gastric adenocarcinoma as regards invasion depth (T category) and metastatic involvement (M category). (author)

  7. Computer guided pre-operative planning and dental implant placement

    Directory of Open Access Journals (Sweden)

    Dušan Grošelj

    2007-05-01

    Full Text Available Background: Implants in dentistry are, besides fixed, removable and maxillofacial prosthodontics, one of the reliable possibility to make functional and aesthetic rehabilitation of the edentulism. Surgical and prosthodontic implant complications are often an inattentive consequence of wrong diagnosis, planning, and placement. In this article we present a technique using a highly advanced software program along with a rapid prototyping technology named stereolithography. A planning software for implant placement needs basically the high quality computed tomographic scan of one or both jaws for making accurate preoperative diagnostics and 3D preoperative plan. Later individual drill guide is designed and generated based on both the CT images and the preoperative planning. The patient specific drill guide transfers the virtual planning to the patient’s mouth at time of surgery.Conclusions: The advantages of computer guided implantology are the better prepared surgery with visualisation of critical anatomic structures, assessment of available bone and data about bone quality, increased confidence for the surgeon, deceased operative time, less frequent use of bone grafts, higher quality of collaboration between specialists and prosthetic lab and better communication with patients. Radiographic examination of the operation field for computer guided planning for implant placement is due to high costs justified as the most important information source on the areas to be implanted.

  8. Axial power deviation control strategy and computer simulation for Daya Bay Nuclear Power Station

    International Nuclear Information System (INIS)

    Liao Yehong; Zhou Xiaoling, Xiao Min

    2004-01-01

    Daya Bay Nuclear Power Station has very tight operation diagram especially at its right side. Therefore the successful control of axial power deviation for PWR is crucial to nuclear safety. After analyzing various core characters' effect on axial power distribution, several axial power deviation control strategies has been proposed to comply with different power varying operation scenario. Application and computer simulation of the strategies has shown that our prediction of axial power deviation evolution are comparable to the measurement values, and that our control strategies are effective. Engineering experience shows that the application of our methodology can predict accurately the transient of axial power deviation, and therefore has become a useful tool for reactor operation and safety control. This paper presents the axial power control characteristics, reactor operation strategy research, computer simulation, and comparison to measurement results in Daya Bay Nuclear Power Station. (author)

  9. Excessive lateral patellar translation on axial computed tomography indicates positive patellar J sign.

    Science.gov (United States)

    Xue, Zhe; Song, Guan-Yang; Liu, Xin; Zhang, Hui; Wu, Guan; Qian, Yi; Feng, Hua

    2018-03-20

    The purpose of the study was to quantify the patellar J sign using traditional computed tomography (CT) scans. Fifty-three patients (fifty-three knees) who suffered from recurrent patellar instability were included and analyzed. The patellar J sign was evaluated pre-operatively during active knee flexion and extension. It was defined as positive when there was obvious lateral patellar translation, and negative when there was not. The CT scans were performed in all patients with full knee extension; and the parameters including bisect offset index (BOI), patellar-trochlear-groove (PTG) distance, and patellar lateral tilt angle (PLTA) were measured on the axial slices. All the three parameters were compared between the J sign-positive group (study group) and the J sign-negative group (control group). In addition, the optimal thresholds of the three CT scan parameters for predicting the positive patellar J sign were determined with receiver operating characteristic (ROC) curves, and the diagnostic values were assessed by the area under the curve (AUC). Among the fifty-three patients (fifty-three knees), thirty-seven (70%) showed obvious lateral patellar translation, which were defined as positive J sign (study group), and the remaining sixteen (30%) who showed no lateral translation were defined as negative J sign (control group). The mean values of the three CT parameters in the study group were all significantly larger compared to the control group, including BOI (121 ± 28% vs 88 ± 12%, P = 0.038), PTG distance (5.2 ± 6.6 mm vs - 4.4 ± 5.2 mm, P J sign was 97.5% (Sensitivity = 83.3%, Specificity = 87.5%). In this study, the prevalence of positive patellar J sign was 70%. The BOI measured from the axial CT scans of the knee joint can be used as an appropriate predictor to differentiate the positive J sign from the negative J sign, highlighting that the excessive lateral patellar translation on axial CT scan indicates positive

  10. Effect of Premolar Axial Wall Height on Computer-Aided Design/Computer-Assisted Manufacture Crown Retention.

    Science.gov (United States)

    Martin, Curt; Harris, Ashley; DuVall, Nicholas; Wajdowicz, Michael; Roberts, Howard Wayne

    2018-03-28

    To evaluate the effect of premolar axial wall height on the retention of adhesive, full-coverage, computer-aided design/computer-assisted manufacture (CAD/CAM) restorations. A total of 48 premolar teeth randomized into four groups (n = 12 per group) received all-ceramic CAD/CAM restorations with axial wall heights (AWH) of 3, 2, 1, and 0 mm and 16-degree total occlusal convergence (TOC). Specimens were restored with lithium disilicate material and cemented with self-adhesive resin cement. Specimens were loaded to failure after 24 hours. The 3- and 2-mm AWH specimens demonstrated significantly greater failure load. Failure analysis suggests a 2-mm minimum AWH for premolars with a TOC of 16 degrees. Adhesive technology may compensate for compromised AWH.

  11. Target localization on standard axial images in computed tomography (CT) stereotaxis for functional neurosurgery - a technical note

    International Nuclear Information System (INIS)

    Patil, A.-A.

    1986-01-01

    A simple technique for marking functional neurosurgery target on computed tomography (CT) axial image is described. This permits the use of standard axial image for computed tomography (CT) stereotaxis in functional neurosurgery. (Author)

  12. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to demonstrate key elements of feasibility for a high speed automated time domain terahertz computed axial tomography (TD-THz CT) non destructive...

  13. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase 2 project, we propose to develop, construct, and deliver to NASA a computed axial tomography time-domain terahertz (CT TD-THz) non destructive...

  14. Diagnostic performance of whole brain volume perfusion CT in intra-axial brain tumors: Preoperative classification accuracy and histopathologic correlation

    International Nuclear Information System (INIS)

    Xyda, Argyro; Haberland, Ulrike; Klotz, Ernst; Jung, Klaus; Bock, Hans Christoph; Schramm, Ramona; Knauth, Michael; Schramm, Peter

    2012-01-01

    Background: To evaluate the preoperative diagnostic power and classification accuracy of perfusion parameters derived from whole brain volume perfusion CT (VPCT) in patients with cerebral tumors. Methods: Sixty-three patients (31 male, 32 female; mean age 55.6 ± 13.9 years), with MRI findings suspected of cerebral lesions, underwent VPCT. Two readers independently evaluated VPCT data. Volumes of interest (VOIs) were marked circumscript around the tumor according to maximum intensity projection volumes, and then mapped automatically onto the cerebral blood volume (CBV), flow (CBF) and permeability Ktrans perfusion datasets. A second VOI was placed in the contra lateral cortex, as control. Correlations among perfusion values, tumor grade, cerebral hemisphere and VOIs were evaluated. Moreover, the diagnostic power of VPCT parameters, by means of positive and negative predictive value, was analyzed. Results: Our cohort included 32 high-grade gliomas WHO III/IV, 18 low-grade I/II, 6 primary cerebral lymphomas, 4 metastases and 3 tumor-like lesions. Ktrans demonstrated the highest sensitivity, specificity and positive predictive value, with a cut-off point of 2.21 mL/100 mL/min, for both the comparisons between high-grade versus low-grade and low-grade versus primary cerebral lymphomas. However, for the differentiation between high-grade and primary cerebral lymphomas, CBF and CBV proved to have 100% specificity and 100% positive predictive value, identifying preoperatively all the histopathologically proven high-grade gliomas. Conclusion: Volumetric perfusion data enable the hemodynamic assessment of the entire tumor extent and provide a method of preoperative differentiation among intra-axial cerebral tumors with promising diagnostic accuracy.

  15. Axial power difference control strategy and computer simulation for GNPS during stretch-out and power decrease

    International Nuclear Information System (INIS)

    Liao Yehong; Xiao Min; Li Xianfeng; Zhu Minhong

    2004-01-01

    Successful control of the axial power difference for PWR is crucial to nuclear safety. After analyzing various elements' effect on the axial power distribution, different axial power deviation control strategies have been proposed to comply with different power decrease scenarios. Application of the strategy to computer simulation shows that our prediction of axial power deviation evolution is comparable to the measurement value, and that our control strategy is effective

  16. Clinical Utility of Preoperative Computed Tomography in Patients With Endometrial Cancer.

    Science.gov (United States)

    Bogani, Giorgio; Gostout, Bobbie S; Dowdy, Sean C; Multinu, Francesco; Casarin, Jvan; Cliby, William A; Frigerio, Luigi; Kim, Bohyun; Weaver, Amy L; Glaser, Gretchen E; Mariani, Andrea

    2017-10-01

    The aim of this study was to determine the clinical utility of routine preoperative pelvic and abdominal computed tomography (CT) examinations in patients with endometrial cancer (EC). We retrospectively reviewed records from patients with EC who underwent a preoperative endometrial biopsy and had surgery at our institution from January 1999 through December 2008. In the subset with an abdominal CT scan obtained within 3 months before surgery, we evaluated the clinical utility of the CT scan. Overall, 224 patients (18%) had a preoperative endometrial biopsy and an available CT scan. Gross intra-abdominal disease was observed in 10% and 20% of patients with preoperative diagnosis of endometrioid G3 and type II EC, respectively, whereas less than 5% of patients had a preoperative diagnosis of hyperplasia or low-grade EC. When examining retroperitoneal findings, we observed that a negative CT scan of the pelvis did not exclude the presence of pelvic node metastasis. Alternately, a negative CT scan in the para-aortic area generally reduced the probability of finding para-aortic dissemination but with an overall low sensitivity (42%). However, the sensitivity for para-aortic dissemination was as high as 67% in patients with G3 endometrioid cancer. In the case of negative para-aortic nodes in the CT scan, the risk of para-aortic node metastases decreased from 18.8% to 7.5% in patients with endometrioid G3 EC. Up to 15% of patients with endometrioid G3 cancer had clinically relevant incidental findings that necessitated medical or surgical intervention. In patients with endometrioid G3 and type II EC diagnosed by the preoperative biopsy, CT scans may help guide the operative plan by facilitating preoperative identification of gross intra-abdominal disease and enlarged positive para-aortic nodes that are not detectable during physical examinations. In addition, CT may reveal other clinically relevant incidental findings.

  17. TRANPZ - A computer code for the simulation of reactors with axial dependence

    International Nuclear Information System (INIS)

    Sampaio, L.C.M.

    1980-12-01

    A computer code was developed to simulate a PWR reactor in steady state and during transients. The solution of one speed diffusion equation in the axial direction is obtained numerically dividing the core in various axial segments and the axial power distribution is obtained there from. A method was developed to determine the transient solution. The external reactivity effects are caused by the motion of the control rods, starting from the steady condition with the control rods in any position. The heat conduction equation in the fuel is numerically solved in the radial direction. Various tests were performed in steady state and transient conditions and the validity of the present model was verified. Results were compared in steady state condition with the code CITATION and a reasonable agreement was found. (E.G.) [pt

  18. Computer-assisted versus non-computer-assisted preoperative planning of corrective osteotomy for extra-articular distal radius malunions: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Stockmans Filip

    2010-12-01

    Full Text Available Abstract Background Malunion is the most common complication of distal radius fracture. It has previously been demonstrated that there is a correlation between the quality of anatomical correction and overall wrist function. However, surgical correction can be difficult because of the often complex anatomy associated with this condition. Computer assisted surgical planning, combined with patient-specific surgical guides, has the potential to improve pre-operative understanding of patient anatomy as well as intra-operative accuracy. For patients with malunion of the distal radius fracture, this technology could significantly improve clinical outcomes that largely depend on the quality of restoration of normal anatomy. Therefore, the objective of this study is to compare patient outcomes after corrective osteotomy for distal radius malunion with and without preoperative computer-assisted planning and peri-operative patient-specific surgical guides. Methods/Design This study is a multi-center randomized controlled trial of conventional planning versus computer-assisted planning for surgical correction of distal radius malunion. Adult patients with extra-articular malunion of the distal radius will be invited to enroll in our study. After providing informed consent, subjects will be randomized to two groups: one group will receive corrective surgery with conventional preoperative planning, while the other will receive corrective surgery with computer-assisted pre-operative planning and peri-operative patient specific surgical guides. In the computer-assisted planning group, a CT scan of the affected forearm as well as the normal, contralateral forearm will be obtained. The images will be used to construct a 3D anatomical model of the defect and patient-specific surgical guides will be manufactured. Outcome will be measured by DASH and PRWE scores, grip strength, radiographic measurements, and patient satisfaction at 3, 6, and 12 months

  19. Comparison of the Multidetector-row Computed Tomographic Angiography Axial and Coronal Planes' Usefulness for Detecting Thoracodorsal Artery Perforators

    Science.gov (United States)

    Kim, Jong Gyu

    2012-01-01

    Background During the planning of a thoracodorsal artery perforator (TDAP) free flap, preoperative multidetector-row computed tomographic (MDCT) angiography is valuable for predicting the locations of perforators. However, CT-based perforator mapping of the thoracodorsal artery is not easy because of its small diameter. Thus, we evaluated 1-mm-thick MDCT images in multiple planes to search for reliable perforators accurately. Methods Between July 2010 and October 2011, 19 consecutive patients (13 males, 6 females) who underwent MDCT prior to TDAP free flap operations were enrolled in this study. Patients ranged in age from 10 to 75 years (mean, 39.3 years). MDCT images were acquired at a thickness of 1 mm in the axial, coronal, and sagittal planes. Results The thoracodorsal artery perforators were detected in all 19 cases. The reliable perforators originating from the descending branch were found in 14 cases, of which 6 had transverse branches. The former were well identified in the coronal view, and the latter in the axial view. The location of the most reliable perforators on MDCT images corresponded well with the surgical findings. Conclusions Though MDCT has been widely used in performing the abdominal perforator free flap for detecting reliable perforating vessels, it is not popular in the TDAP free flap. The results of this study suggest that multiple planes of MDCT may increase the probability of detecting the most reliable perforators, along with decreasing the probability of missing available vessels. PMID:22872839

  20. Spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies

    International Nuclear Information System (INIS)

    Prokesch, R.; Bankier, A.; Ba-Ssalamah, A.; Imhof, H.; Lakits, A.; Scholda, C.

    1998-01-01

    Purpose: To compare the effectiveness of spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies. Results: All foreign bodies were detected by each scanning modality on the axial and on the reconstructed planes. The quality of the axial images was similar for spiral and conventional CT. The spiral technique provided high-quality reconstructed images which allowed accurate localization of the foreign bodies in all cases. Reconstructions by conventional technique were inadequate for preoperative assessment. The examination time for the total orbital volume was 18 s for spiral CT and 52 s for conventional CT. Radiation dose delivered to the lens was 35 mGy for spiral CT and 56 mGy for conventional CT axial scanning. Conclusion: Spiral CT multiplanar offers several significant advantages for the preoperative assessment of metallic intraocular foreign bodies compared to the conventional CT technique in clinical practice, including short examination time, minimized motion artifacts, reduced radiation exposure, and accurate localization. (orig.) [de

  1. Computer aided hydraulic design of axial flow pump impeller

    International Nuclear Information System (INIS)

    Sreedhar, B.K.; Rao, A.S.L.K.; Kumaraswamy, S.

    1994-01-01

    Pumps are the heart of any power plant and hence their design requires great attention. Computers with their potential for rapid computation can be successfully employed in the design and manufacture of these machines. The paper discusses a program developed for the hydraulic design of axial flow pump impeller. The program, written in FORTRAN 77, is interactive and performs the functions of design calculation, drafting and generation of numerical data for blade manufacture. The drafting function, which makes use of the software ACAD, is carried out automatically by means of suitable interface programs. In addition data for blade manufacture is also generated in either the x-y-z or r-θ-z system. (author). 4 refs., 3 figs

  2. Medullary sponge kidney on axial computed tomography

    International Nuclear Information System (INIS)

    Ginalski, J.-M.; Schnyder, Pierre; Portmann, Luc; Jaeger, Philippe

    1991-01-01

    To evaluate features of medullary sponge kidney (MSK) on computed tomography (CT), 4-mm-thick axial slices without intravenous contrast material were 1st made in 13 patients through 24 kidneys which showed images of MSK on excretory urograms. On CT, papillary calcifications were found in 11 kidneys. In 5 of these, the calcifications were not detectable on plain films. Some hyperdense papillae (attenuation value 55-70 Hounsfield units) without calcification were found in 4 other kidneys. 9 kidneys appeared normal. 10 of the 14 kidneys were reexamined by a 2nd series of 4-mm-thick axial slices, 5 min after intravenous injection of 50 ml of Urografin. Images suggesting possible ectasia of precaliceal tubules were found in only 4 kidneys. These images appear much less obvious and characteristic on CT than on excretory urogram and do nothing more than suggest the possibility of MSK. In conclusion, the sensitivity of CT in the detection of MSK is markedly lower than that of excretory urography. In the most florid cases of the disease, CT can only show images suggesting the possibility of MSK. On the other hand, CT appears much more sensitive than plain films and tomograms of excretory in the detection of papillary calcifications, the most frequent complication of MSK. (author). 13 refs.; 3 figs

  3. The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas

    International Nuclear Information System (INIS)

    Krestan, C.; Czerny, C.; Gstoettner, W.; Franz, P.

    2003-01-01

    The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. Postoperative HRCT depicted bony erosions caused by recurrent cholesteatoma, bony defects of the facial nerve and of the labyrinth, and a defect of the tegmen tympani with a soft tissue mass in the middle ear. Postoperative MRI delineated neuritis of the facial nerve, labyrinthitis, and a meningo-encephalocele protruding into the middle ear. HRCT and MRI are excellent imaging tools to depict either bony or soft tissue complications or both if caused by acquired cholesteatomas. According to our findings and to the literature HRCT and MRI are complementary imaging methods to depict pre- or postoperative complications of acquired cholesteatomas if these are suspected by clinical examination. (orig.) [de

  4. Preoperative cardiac computed tomography for demonstration of congenital cardiac septal defect in adults

    Energy Technology Data Exchange (ETDEWEB)

    Eom, Hye-Joung; Yang, Dong Hyun; Kang, Joon-Won; Lim, Tae-Hwan [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Cardiac Imaging Center, Asan Medical Center, Seoul (Korea, Republic of); Kim, Dae-Hee; Song, Jong-Min; Kang, Duk-Hyun; Song, Jae-Kwan [University of Ulsan College of Medicine, Department of Cardiology and Heart Institute, Cardiac Imaging Center, Asan Medical Center, Seoul (Korea, Republic of); Kim, Joon Bum; Jung, Sung-Ho; Choo, Suk Jung; Chung, Cheol Hyun; Lee, Jae Won [University of Ulsan College of Medicine, Department of Cardiothoracic surgery, Cardiac Imaging Center, Asan Medical Center, Seoul (Korea, Republic of)

    2015-06-01

    We aimed to evaluate the role of preoperative cardiac computed tomography (CT) for adults with congenital cardiac septal defect (CSD). Sixty-five consecutive patients who underwent preoperative CT and surgery for CSD were included. The diagnostic accuracy of CT and the concordance rate of the subtype classification of CSD were evaluated using surgical findings as the reference standard. Sixty-five patients without CSD who underwent cardiac valve surgery were used as a control group. An incremental value of CT over echocardiography was described retrospectively. Sensitivity and specificity of CT for diagnosis of CSD were 95 % and 100 %, respectively. The concordance rate of subtype classification was 91 % in CT and 92 % in echocardiography. The maximum size of the defect measured by CT correlated well with surgical measurement (r = 0.82), and the limit of agreement was -0.9 ± 7.42 mm. In comparison with echocardiography, CT was able to detect combined abnormalities in three cases, and exclusively provided correct subtype classification or clarified suspected abnormal findings found on echocardiography in seven cases. Cardiac CT can accurately demonstrates CSD in preoperative adult patients. CT may have an incremental role in preoperative planning, particularly in those with more complex anatomy. (orig.)

  5. Axial Torsion of Gangrenous Meckel's Diverticulum Causing Small ...

    African Journals Online (AJOL)

    dividing the band. Resection and anastomosis of the small bowel including the MD was performed. We hereby report a rare and unusual complication of a MD. Although treatment outcome is generally good, pre-operative diagnosis is often difficult. Key words: Axial torsion, Meckel's diverticulum, small bowel obstruction.

  6. Endoscopic ultrasonography and computed tomography scanning for preoperative staging of colonic cancer

    DEFF Research Database (Denmark)

    Malmstrøm, M L; Gögenur, I; Riis, L B

    2017-01-01

    PURPOSE: With an increasing demand for more accurate preoperative staging methods for colon cancer, we aimed to compare preoperative tumour (T)- and nodal (N)-stage in patients with left-sided colon cancer by endoscopic ultrasonography (EUS) and computed tomography (CT) with post......-operative histology as gold standard. METHODS: A total of 44 patients were prospectively recruited at Herlev and Roskilde University Hospitals during November 2014-January 2016. Thirty-five patients were included in the final analysis and underwent EUS, CT and surgery within 2 weeks. Diagnostic values were evaluated...... difficult to evaluate due to small patient numbers. EUS could be considered as a supplement to CT scans in selecting patients for neoadjuvant therapies, or local transmural treatment, in the future. TRIAL REGISTRATION: NCT02324023....

  7. Transverse axial plane anatomy of the temporal bone employing high spatial resolution computed tomography

    International Nuclear Information System (INIS)

    Russell, E.J.; Koslow, M.; Lasjaunias, P.; Bergeron, R.T.; Chase, N.

    1982-01-01

    Anatomical relationships of temporal bone structures are demonstrated by thin section edge detection computed tomography. Many otic structures are best appreciated in axial view, but reorientation to anatomy as seen in this plane is needed for optimal diagnosis. A level by level review of key structure is presented toward this end. The limitations and advantages of computed tomography are discussed. (orig.)

  8. Identification of a unique cause of ring artifact seen in computed tomography trans-axial images

    International Nuclear Information System (INIS)

    Jha, Ashish Kumar; Purandare, Nilendu C; Shah, Sneha; Agrawal, Archi; Puranik, Ameya D; Rangarajan, Venkatesh

    2013-01-01

    Artifacts present in computed tomography (CT) image often degrade the image quality and ultimately, the diagnostic outcome. Ring artifact in trans-axial image is caused by either miscalibrated or defective detector element of detector row, which is often categorized as scanner based artifact. A ring artifact detected on trans-axial CT image of positron emission tomography/computed tomography (PET/CT), was caused by contamination of CT tube aperture by droplet of injectable contrast medium. This artifact was corrected by removal of contrast droplet from CT tube aperture. The ring artifact is a very common artifact, commonly cited in the literature. Our case puts forward an uncommon cause of this artifact and its method of correction, which also, has no mention in the existing literature

  9. Preoperative classification of ovarial tumors by means of computed tomography

    International Nuclear Information System (INIS)

    Steinbrich, W.; Rohde, U.

    1982-01-01

    127 histologically demonstrated ovarial tumors were studied in a blindfold test in order to find out to what extent a preoperative determination of dignity or diagnosis of the tumor kind is possible by computed tomography. The overall rate of correct determinations of dignity is 82%. In case of functional cysts and cystomas with thin cyst walls, cystadenocarcinomas and dermoid cysts, this rate is about 95%, whereas the classification results are less exact in case of cystic tumors with broadened cyst walls, preponderantly solid tumors and tumor-like lesions. (orig.) [de

  10. Computed tomography of the facial canal

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1983-01-01

    The radiological details of the facial canal was investigated by computed tomography. In the first part of this study, dry skulls were used to delineate the full course of the facial canal by computed tomography. In the second part of this study, the patients with chronic otitis media and secondary cholesteatoma were evaluated. The labyrinthine and tympanic parts of the canal were well demonstrated with the axial scanning, and the mastoid part with the coronal scanning. Moreover, computed tomography showed excellent delineation of the middle ear contents. In patients with secondary cholesteatoma, the destructions of the intratympanic course of the bony facial canal were also assessed preoperatively. (author)

  11. Preoperative (3-dimensional) computed tomography lung reconstruction before anatomic segmentectomy or lobectomy for stage I non-small cell lung cancer.

    Science.gov (United States)

    Chan, Ernest G; Landreneau, James R; Schuchert, Matthew J; Odell, David D; Gu, Suicheng; Pu, Jiantao; Luketich, James D; Landreneau, Rodney J

    2015-09-01

    Accurate cancer localization and negative resection margins are necessary for successful segmentectomy. In this study, we evaluate a newly developed software package that permits automated segmentation of the pulmonary parenchyma, allowing 3-dimensional assessment of tumor size, location, and estimates of surgical margins. A pilot study using a newly developed 3-dimensional computed tomography analytic software package was performed to retrospectively evaluate preoperative computed tomography images of patients who underwent segmentectomy (n = 36) or lobectomy (n = 15) for stage 1 non-small cell lung cancer. The software accomplishes an automated reconstruction of anatomic pulmonary segments of the lung based on bronchial arborization. Estimates of anticipated surgical margins and pulmonary segmental volume were made on the basis of 3-dimensional reconstruction. Autosegmentation was achieved in 72.7% (32/44) of preoperative computed tomography images with slice thicknesses of 3 mm or less. Reasons for segmentation failure included local severe emphysema or pneumonitis, and lower computed tomography resolution. Tumor segmental localization was achieved in all autosegmented studies. The 3-dimensional computed tomography analysis provided a positive predictive value of 87% in predicting a marginal clearance greater than 1 cm and a 75% positive predictive value in predicting a margin to tumor diameter ratio greater than 1 in relation to the surgical pathology assessment. This preoperative 3-dimensional computed tomography analysis of segmental anatomy can confirm the tumor location within an anatomic segment and aid in predicting surgical margins. This 3-dimensional computed tomography information may assist in the preoperative assessment regarding the suitability of segmentectomy for peripheral lung cancers. Published by Elsevier Inc.

  12. Multidetector Computed Tomography in the Preoperative Workup of Hilar Cholangiocarcinoma

    International Nuclear Information System (INIS)

    Kim, Hyoung Jung; Lee, Dong Ho; Lim, Joo Won; Ko, Young Tae

    2009-01-01

    Hilar cholangiocarcinoma is associated with a dismal prognosis; however, curative resection may offer a chance of cure. Various factors should be considered in the surgical planning for curative resection. These factors include extent of bile duct involvement, relationship between portal vein and tumor involvement, diffuse hepato duodenal ligament infiltration, vascular invasion, lymph node metastasis, peritoneal seeding, and hepatic volume. Using high-quality volume data from multidetector-row computed tomography (MDCT) and adequate postprocessing images, radiologists can provide various types of information, imperative for curative resection of a hilar cholangiocarcinoma. This review illustrates the role of MDCT in the preoperative workup of hilar cholangiocarcinoma

  13. Reducing radiation dose without compromising image quality in preoperative perforator flap imaging with CTA using ASIR technology.

    Science.gov (United States)

    Niumsawatt, Vachara; Debrotwir, Andrew N; Rozen, Warren Matthew

    2014-01-01

    Computed tomographic angiography (CTA) has become a mainstay in preoperative perforator flap planning in the modern era of reconstructive surgery. However, the increased use of CTA does raise the concern of radiation exposure to patients. Several techniques have been developed to decrease radiation dosage without compromising image quality, with varying results. The most recent advance is in the improvement of image reconstruction using an adaptive statistical iterative reconstruction (ASIR) algorithm. We sought to evaluate the image quality of ASIR in preoperative deep inferior epigastric perforator (DIEP) flap surgery, through a direct comparison with conventional filtered back projection (FBP) images. A prospective review of 60 consecutive ASIR and 60 consecutive FBP CTA images using similar protocol (except for radiation dosage) was undertaken, analyzed by 2 independent reviewers. In both groups, we were able to accurately identify axial arteries and their perforators. Subjective analysis of image quality demonstrated no statistically significant difference between techniques. ASIR can thus be used for preoperative imaging with similar image quality to FBP, but with a 60% reduction in radiation delivery to patients.

  14. Computer-assisted preoperative simulation for positioning and fixation of plate in 2-stage procedure combining maxillary advancement by distraction technique and mandibular setback surgery.

    Science.gov (United States)

    Suenaga, Hideyuki; Taniguchi, Asako; Yonenaga, Kazumichi; Hoshi, Kazuto; Takato, Tsuyoshi

    2016-01-01

    Computer-assisted preoperative simulation surgery is employed to plan and interact with the 3D images during the orthognathic procedure. It is useful for positioning and fixation of maxilla by a plate. We report a case of maxillary retrusion by a bilateral cleft lip and palate, in which a 2-stage orthognathic procedure (maxillary advancement by distraction technique and mandibular setback surgery) was performed following a computer-assisted preoperative simulation planning to achieve the positioning and fixation of the plate. A high accuracy was achieved in the present case. A 21-year-old male patient presented to our department with a complaint of maxillary retrusion following bilateral cleft lip and palate. Computer-assisted preoperative simulation with 2-stage orthognathic procedure using distraction technique and mandibular setback surgery was planned. The preoperative planning of the procedure resulted in good aesthetic outcomes. The error of the maxillary position was less than 1mm. The implementation of the computer-assisted preoperative simulation for the positioning and fixation of plate in 2-stage orthognathic procedure using distraction technique and mandibular setback surgery yielded good results. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  15. A review of X-ray computed axial tomography

    International Nuclear Information System (INIS)

    Schmidt, M.

    1989-01-01

    A review of Computed axial tomography (CAT) scanning literature outlining the theoretical and practical aspects of this technique with application in both medical diagnosis and industrial non-destructive inspection (NDI) is presented. Practical aspects of CAT scanning discussed include : radiation sources, currently available spatial and contrast resolution limits and the evolution of the computerized tomography (CT) system. It was found that monochromatic gamma rays are preferred to X-rays, especially for very high density materials, and that in medical CAT scanning, the special resolution is only, 0.5 mm while spatial resolutions of less than 50μm have been achieved in NDI. An increased number of scientific and industrial applications are anticipated (e.g. for studying sintering reactions), as the capital cost of CAT scanning decreased. 13 refs., 9 figs., 2 tabs

  16. Preoperative localization of endocrine pancreatic tumours by intra-arterial dynamic computed tomography

    International Nuclear Information System (INIS)

    Ahlstroem, H.; Magnusson, A.; Grama, D.; Eriksson, B.; Oeberg, K.; Loerelius, L.E.; Akademiska Sjukhuset, Uppsala; Akademiska Sjukhuset, Uppsala

    1990-01-01

    Eleven patients with biochemically confirmed endocrine pancreatic tumours were examined with intra-arterial (i.a.) dynamic computed tomography (CT) and angiography preoperatively. Seven of the patients suffered from the multiple endocrine neoplasia type 1 (MEN-1) syndrome. All patients were operated upon and surgical palpation and ultrasound were the peroperative localization methods. Of the 33 tumours which were found at histopathologic analysis of the resected specimens in the 11 patients, 7 tumours in 7 patients were correctly localized by both i.a. dynamic CT and angiography. Six patients with MEN-1 syndrome had multiple tumours and this group of patients together had 28 tumours, of which 5 (18%) were localized preoperatively by both CT and angiography. I.a. dynamic CT, with the technique used by us, does not seem to improve the localization of endocrine pancreatic tumours, especially in the rare group of MEN-1 patients, as compared with angiography. (orig.)

  17. Techniques for computing reactivity changes caused by fuel axial expansion in LMR's

    International Nuclear Information System (INIS)

    Khalil, H.

    1988-01-01

    An evaluation is made of the accuracy of methods used to compute reactivity changes caused by axial fuel relocation in fast reactors. Results are presented to demonstrate the validity of assumptions commonly made such as linearity of reactivity with fuel elongation, additivity of local reactivity contributions, and the adequacy of standard perturbation techniques. Accurate prediction of the reactivity loss caused by axial swelling of metallic fuel is shown to require proper representation of the burnup dependence of the expansion reactivity. Some accuracy limitations in the methods used in transient analyses, which are based on the use of fuel worth tables, are identified, and efficient ways to improve accuracy are described. Implementation of these corrections produced expansion reactivity estimates within 5% of higher-order method for a metal-fueled FFTF core representation. 18 refs., 3 figs., 3 tabs

  18. Preoperative magnetic resonance imaging protocol for endoscopic cranial base image-guided surgery.

    Science.gov (United States)

    Grindle, Christopher R; Curry, Joseph M; Kang, Melissa D; Evans, James J; Rosen, Marc R

    2011-01-01

    Despite the increasing utilization of image-guided surgery, no radiology protocols for obtaining magnetic resonance (MR) imaging of adequate quality are available in the current literature. At our institution, more than 300 endonasal cranial base procedures including pituitary, extended pituitary, and other anterior skullbase procedures have been performed in the past 3 years. To facilitate and optimize preoperative evaluation and assessment, there was a need to develop a magnetic resonance protocol. Retrospective Technical Assessment was performed. Through a collaborative effort between the otolaryngology, neurosurgery, and neuroradiology departments at our institution, a skull base MR image-guided (IGS) protocol was developed with several ends in mind. First, it was necessary to generate diagnostic images useful for the more frequently seen pathologies to improve work flow and limit the expense and inefficiency of case specific MR studies. Second, it was necessary to generate sequences useful for IGS, preferably using sequences that best highlight that lesion. Currently, at our institution, all MR images used for IGS are obtained using this protocol as part of preoperative planning. The protocol that has been developed allows for thin cut precontrast and postcontrast axial cuts that can be used to plan intraoperative image guidance. It also obtains a thin cut T2 axial series that can be compiled separately for intraoperative imaging, or may be fused with computed tomographic images for combined modality. The outlined protocol obtains image sequences effective for diagnostic and operative purposes for image-guided surgery using both T1 and T2 sequences. Copyright © 2011 Elsevier Inc. All rights reserved.

  19. Diagnostic yield of preoperative computed tomography imaging and the importance of a clinical decision for lung cancer surgery

    International Nuclear Information System (INIS)

    Sato, Shuichi; Koike, Teruaki; Yamato, Yasushi

    2010-01-01

    This study aimed to evaluate the diagnostic yield of preoperative computed tomography (CT) imaging and the validity of surgical intervention based on the clinical decision to perform surgery for lung cancer or suspected lung cancer. We retrospectively evaluated 1755 patients who had undergone pulmonary resection for lung cancer or suspected lung cancer. CT scans were performed on all patients. Surgical intervention to diagnose and treat was based on a medical staff conference evaluation for the suspected lung cancer patients who were pathologically undiagnosed. We evaluated the relation between resected specimens and preoperative CT imaging in detail. A total of 1289 patients were diagnosed with lung cancer by preoperative pathology examination; another 466 were not pathologically diagnosed preoperatively. Among the 1289 patients preoperatively diagnosed with lung cancer, the diagnoses were confirmed postoperatively in 1282. Among the 466 patients preoperatively undiagnosed, 435 were definitively diagnosed with lung cancer, and there were 383 p-stage I disease patients. There were 38 noncancerous patients who underwent surgery with a diagnosis of confirmed or suspected lung cancer. Among the 1755 patients who underwent surgery, 1717 were pathologically confirmed with lung cancer, and the diagnostic yield of preoperative CT imaging was 97.8%. Among the 466 patients who were preoperatively undiagnosed, 435 were compatible with the predicted findings of lung cancer. Diagnostic yields of preoperative CT imaging based on clinical evaluation are sufficiently reliable. Diagnostic surgical intervention was acceptable when the clinical probability of malignancy was high and the malignancy was pathologically undiagnosed. (author)

  20. The usefulness of multiplanar reconstruction images in preoperative t-staging of advanced gastric cancer

    International Nuclear Information System (INIS)

    Koo, Young Baek; Kim, Suk; Lee, Jun Woo; Kim, Soo Jin; Choo, Ki Seok; Lee, Tae Hong; Moon, Tae Yong; Lee, Suk Hong; Jeon, Tae Yong

    2004-01-01

    The purpose of this study was to evaluate the performance of multidetector-row CT (MDCT) in the preoperative T-staging of patients with advanced gastric cancer. A total of 65 patients with an established diagnosis of advanced gastric cancer (T2 or more) were evaluated with MDCT. The protocol of MDCT consisted of high-quality (HQ) mode helical scanning with a slice thickness of 2.5 mm. The axial CT images were reconstructed with a slice thickness of 5 mm. MPR images were reconstructed from the raw axial data with a slice thickness of 5 mm. A comparison between the standard axial and axial MPR images was performed by two radiologists with regard to the evaluation of the tumor location and T-stage. These findings were compared with the pathologic and surgical findings. T-staging of the advanced stomach cancer was correct in 89% (58/65) and 69% (45/65) of the MPR images and axial images, respectively. The MPR images improved the detection rate (5 lesions) of the tumors and increased the accuracy of the T-staging (13 lesions) in comparison with the axial images. The MPR images are of greater diagnostic value for the evaluation of omental seeding (5 lesions: axial images, 9 lesions: MPR images), tumor location and extension. Multiplanar reconstruction (MPR) images provide increased confidence in the location and T-staging of certain cases of advanced gastric cancer, such as those in locations where CT images are susceptible to be affected by the difficulties associated with partial volume averaging. In this study, the MPR images provided more precise information about the tumor location and T-staging than the standard axial images in the preoperative evaluation of advanced gastric cancer

  1. Preoperative evaluation of renal anatomy and renal masses with helical CT, 3D-CT and 3D-CT angiography.

    Science.gov (United States)

    Toprak, Uğur; Erdoğan, Aysun; Gülbay, Mutlu; Karademir, Mehmet Alp; Paşaoğlu, Eşref; Akar, Okkeş Emrah

    2005-03-01

    The aim of this prospective study was to determine the efficacy of three-dimensional computed tomography (3D-CT) and three-dimensional computed tomographic angiography (3D-CTA) that were reconstructed by using the axial images of the multiphasic helical CT in the preoperative evaluation of renal masses and demonstration of renal anatomy. Twenty patients that were suspected of having renal masses upon initial physical examination and ultrasonographic evaluation were examined through multiphasic helical CT. Two authors executed CT evaluations. Axial images were first examined and then used to reconstruct 3D-CT and 3D- CTA images. Number, location and size of the renal masses and other findings were noted. Renal vascularization and relationships of the renal masses with the neighboring renal structures were further investigated with 3D-CT and 3D-CTA images. Out of 20 patients, 13 had histopathologically proven renal cell carcinoma. The diagnoses of the remaining seven patients were xanthogranulomatous pyelonephritis, abscess, simple cyst, infected cyst, angiomyolipoma, oncocytoma and arteriovenous fistula. In the renal cell carcinoma group, 3 patients had stage I, 7 patients had stage II, and 3 patients had stage III disease. Sizes of renal cell carcinoma masses were between 23 mm to 60 mm (mean, 36 mm). Vascular invasion was shown in 2 renal cell carcinoma patients. Collecting system invasion was identified in 11 of 13 renal cell patients. These radiologic findings were confirmed with surgical specimens. Three-dimensional CT and 3D-CTA are non-invasive, effective imaging techniques for the preoperative evaluation of renal masses.

  2. The 'Lumbar Fusion Outcome Score' (LUFOS): a new practical and surgically oriented grading system for preoperative prediction of surgical outcomes after lumbar spinal fusion in patients with degenerative disc disease and refractory chronic axial low back pain.

    Science.gov (United States)

    Mattei, Tobias A; Rehman, Azeem A; Teles, Alisson R; Aldag, Jean C; Dinh, Dzung H; McCall, Todd D

    2017-01-01

    In order to evaluate the predictive effect of non-invasive preoperative imaging methods on surgical outcomes of lumbar fusion for patients with degenerative disc disease (DDD) and refractory chronic axial low back pain (LBP), the authors conducted a retrospective review of 45 patients with DDD and refractory LBP submitted to anterior lumbar interbody fusion (ALIF) at a single center from 2007 to 2010. Surgical outcomes - as measured by Visual Analog Scale (VAS/back pain) and Oswestry Disability Index (ODI) - were evaluated pre-operatively and at 6 weeks, 3 months, 6 months, and 1 year post-operatively. Linear mixed-effects models were generated in order to identify possible preoperative imaging characteristics (including bone scan/99mTc scintigraphy increased endplate uptake, Modic endplate changes, and disc degeneration graded according to Pfirrmann classification) which may be predictive of long-term surgical outcomes . After controlling for confounders, a combined score, the Lumbar Fusion Outcome Score (LUFOS), was developed. The LUFOS grading system was able to stratify patients in two general groups (Non-surgical: LUFOS 0 and 1; Surgical: LUFOS 2 and 3) that presented significantly different surgical outcomes in terms of estimated marginal means of VAS/back pain (p = 0.001) and ODI (p = 0.006) beginning at 3 months and continuing up to 1 year of follow-up. In conclusion,  LUFOS has been devised as a new practical and surgically oriented grading system based on simple key parameters from non-invasive preoperative imaging exams (magnetic resonance imaging/MRI and bone scan/99mTc scintigraphy) which has been shown to be highly predictive of surgical outcomes of patients undergoing lumbar fusion for treatment for refractory chronic axial LBP.

  3. Focused review on transthoracic echocardiographic assessment of patients with continuous axial left ventricular assist devices.

    Science.gov (United States)

    Topilsky, Yan; Maltais, Simon; Oh, Jae K; Atchison, Fawn W; Perrault, Louis P; Carrier, Michel; Park, Soon J

    2011-02-08

    Left ventricular assist devices (LVADs) are systems for mechanical support for patients with end-stage heart failure. Preoperative, postoperative and comprehensive followup with transthoracic echocardiography has a major role in LVAD patient management. In this paper, we will present briefly the hemodynamics of axial-flow LVAD, the rationale, and available data for a complete and organized echocardiographic assessment in these patients including preoperative assessment, postoperative and long-term evaluation.

  4. Rare location of spondylitis tuberculosis;atlanto-axial, sacral and cervico-thoracic junction

    Science.gov (United States)

    Victorio; Nasution, M. D.; Ibrahim, S.; Dharmajaya, R.

    2018-03-01

    Three cases of rare location spondylitis tuberculosis are reported, each in atlantoaxial, cervico-thoracic junction,and sacral. The complaints were aweakness of motoric strength and local back pain. Patients’thoracal x-ray was normal, there was no complaint of acough, PCR forTB was early diagnostic and positive in all three cases, HIV negative, intraoperative tissue samplings were sent for histopathology examination and the results showed thespecific inflammatory process. Lesions were evaluated with computer tomography and/or MRI imaging.Preoperative TB regimens therapy were given for 2 weeks and continued for nine months. The surgical procedurewas done in all cases with excellent improvement of symptoms and motoric strength. In our institution,25 cases of total TB spondylitis were performed in 2 years, only 1 case eachwas found in atlanto-axial, cervico-thoracic and sacral.

  5. Computer assisted surgery in preoperative planning of acetabular fracture surgery: state of the art.

    Science.gov (United States)

    Boudissa, Mehdi; Courvoisier, Aurélien; Chabanas, Matthieu; Tonetti, Jérôme

    2018-01-01

    The development of imaging modalities and computer technology provides a new approach in acetabular surgery. Areas covered: This review describes the role of computer-assisted surgery (CAS) in understanding of the fracture patterns, in the virtual preoperative planning of the surgery and in the use of custom-made plates in acetabular fractures with or without 3D printing technologies. A Pubmed internet research of the English literature of the last 20 years was carried out about studies concerning computer-assisted surgery in acetabular fractures. The several steps for CAS in acetabular fracture surgery are presented and commented by the main author regarding to his personal experience. Expert commentary: Computer-assisted surgery in acetabular fractures is still initial experiences with promising results. Patient-specific biomechanical models considering soft tissues should be developed to allow a more realistic planning.

  6. CT-MR image data fusion for computer assisted navigated neurosurgery of temporal bone tumors

    International Nuclear Information System (INIS)

    Nemec, Stefan Franz; Donat, Markus Alexander; Mehrain, Sheida; Friedrich, Klaus; Krestan, Christian; Matula, Christian; Imhof, Herwig; Czerny, Christian

    2007-01-01

    Purpose: To demonstrate the value of multi detector computed tomography (MDCT) and magnetic resonance imaging (MRI) in the preoperative work up of temporal bone tumors and to present, especially, CT and MR image fusion for surgical planning and performance in computer assisted navigated neurosurgery of temporal bone tumors. Materials and methods: Fifteen patients with temporal bone tumors underwent MDCT and MRI. MDCT was performed in high-resolution bone window level setting in axial plane. The reconstructed MDCT slice thickness was 0.8 mm. MRI was performed in axial and coronal plane with T2-weighted fast spin-echo (FSE) sequences, un-enhanced and contrast-enhanced T1-weighted spin-echo (SE) sequences, and coronal T1-weighted SE sequences with fat suppression and with 3D T1-weighted gradient-echo (GE) contrast-enhanced sequences in axial plane. The 3D T1-weighted GE sequence had a slice thickness of 1 mm. Image data sets of CT and 3D T1-weighted GE sequences were merged utilizing a workstation to create CT-MR fusion images. MDCT and MR images were separately used to depict and characterize lesions. The fusion images were utilized for interventional planning and intraoperative image guidance. The intraoperative accuracy of the navigation unit was measured, defined as the deviation between the same landmark in the navigation image and the patient. Results: Tumorous lesions of bone and soft tissue were well delineated and characterized by CT and MR images. The images played a crucial role in the differentiation of benign and malignant pathologies, which consisted of 13 benign and 2 malignant tumors. The CT-MR fusion images supported the surgeon in preoperative planning and improved surgical performance. The mean intraoperative accuracy of the navigation system was 1.25 mm. Conclusion: CT and MRI are essential in the preoperative work up of temporal bone tumors. CT-MR image data fusion presents an accurate tool for planning the correct surgical procedure and is a

  7. SPECT: Theoretical aspecte and evolution of emission computed axial tomography

    International Nuclear Information System (INIS)

    Brunol, J.; Nuta, V.

    1981-01-01

    We have detailed certain of the elements of 3-D image reconstruction from axial projections. Two of the aspects specific to nuclear medicine have been analysed namely self-absorption and statistics. In our view, the development of ECAT in the months to come must hence proceed in two essential directions: - application to dynamic cardiac imagery (multigated). Results of this type have been obtained over 8 months in the Radioisotope Service of Cochin Hospital in Paris. It must be stressed here that the number of images to be processed then becomes considerable (multiplication by the gate factor yielding more than 100 images), the more the statistics are reduced due to the fact of the temporal separation. The obtaining of good image quality requires sophisticated quadri-dimensional processing. It follows that the computing times, with all the mini-computers available in nuclear medicine, then become much too great to envisage really application in hospital routine (several hours of computing). This is the reason why we connected an array processor with the IMAC system. This very powerful system (several tens of times the power of a mini-computer) will reduce the time of such computing to less than 10 minutes. New elements can be introduced into the reconstruction algorithm (static case opposite the foregoing one). These important elements of improvement are to the detriment of space and hence of computing time. Here again, the use of an array processor appears indispensable. It is to recall that the ECAT is today a currently used method, the theoretical analyses that it has necessitated have opened the way to new effective methods of tomography by 'Slanted Hole'. (orig.) [de

  8. Computer axial tomography in geosciences

    International Nuclear Information System (INIS)

    Duliu, Octavian G.

    2002-01-01

    Computer Axial Tomography (CAT) is one of the most adequate non-invasive techniques for the investigation of the internal structure of a large category of objects. Initially designed for medical investigations, this technique, based on the attenuation of X- or gamma-ray (and in some cases neutrons), generates digital images which map the numerical values of the linear attenuation coefficient of a section or of the entire volume of the investigated sample. Shortly after its application in medicine, CAT has been successfully used in archaeology, life sciences, and geosciences as well as for the industrial materials non-destructive testing. Depending on the energy of the utilized radiation as well as on the effective atomic number of the sample, CAT can provide with a spatial resolution of 0.01 - 0.5 mm, quantitative as well as qualitative information concerning local density, porosity or chemical composition of the sample. At present two types of axial Computer Tomographs (CT) are in use. One category, consisting of medical as well as industrial CT is equipped with X-ray tubes while the other uses isotopic gamma-ray sources. CT provided with intense X-ray sources (equivalent to 12-15 kCi or 450-550 TBq) has the advantage of an extremely short running time (a few seconds and even less) but presents some disadvantages known as beam hardening and absorption edge effects. These effects, intrinsically related to the polychromatic nature of the X-rays generated by classical tubes, need special mathematical or physical corrections. A polychromatic X-ray beam can be made almost monochromatic by means of crystal diffraction or by using adequate multicomponent filters, but these devices are costly and considerably diminish the output of X-ray generators. In the case of CT of the second type, monochromatic gamma-rays generated by radioisotopic sources, such as 169 Yb (50.4 keV), 241 Am (59 keV), 192 Ir (310.5 and 469.1 keV ) or 137 Cs (662.7 keV), are used in combination with

  9. Preoperative PET/CT in early-stage breast cancer

    DEFF Research Database (Denmark)

    Bernsdorf, M; Berthelsen, A K; Timmermans-Wielenga, Vera

    2012-01-01

    The aim of this study was to assess the diagnostic and therapeutic impact of preoperative positron emission tomography and computed tomography (PET/CT) in the initial staging of patients with early-stage breast cancer.......The aim of this study was to assess the diagnostic and therapeutic impact of preoperative positron emission tomography and computed tomography (PET/CT) in the initial staging of patients with early-stage breast cancer....

  10. Assessment of 12 CHF prediction methods, for an axially non-uniform heat flux distribution, with the RELAP5 computer code

    Energy Technology Data Exchange (ETDEWEB)

    Ferrouk, M. [Laboratoire du Genie Physique des Hydrocarbures, University of Boumerdes, Boumerdes 35000 (Algeria)], E-mail: m_ferrouk@yahoo.fr; Aissani, S. [Laboratoire du Genie Physique des Hydrocarbures, University of Boumerdes, Boumerdes 35000 (Algeria); D' Auria, F.; DelNevo, A.; Salah, A. Bousbia [Dipartimento di Ingegneria Meccanica, Nucleare e della Produzione, Universita di Pisa (Italy)

    2008-10-15

    The present article covers the evaluation of the performance of twelve critical heat flux methods/correlations published in the open literature. The study concerns the simulation of an axially non-uniform heat flux distribution with the RELAP5 computer code in a single boiling water reactor channel benchmark problem. The nodalization scheme employed for the considered particular geometry, as modelled in RELAP5 code, is described. For this purpose a review of critical heat flux models/correlations applicable to non-uniform axial heat profile is provided. Simulation results using the RELAP5 code and those obtained from our computer program, based on three type predictions methods such as local conditions, F-factor and boiling length average approaches were compared.

  11. Computed tomography for preoperative planning in total hip arthroplasty: what radiologists need to know

    Energy Technology Data Exchange (ETDEWEB)

    Huppertz, Alexander [Charite - University Hospitals Berlin, Department of Radiology, Berlin (Germany); Imaging Science Institute Charite, Berlin (Germany); Radmer, Sebastian [Proendo, Orthopedic Surgery, Berlin (Germany); Wagner, Moritz; Hamm, Bernd [Charite - University Hospitals Berlin, Department of Radiology, Berlin (Germany); Roessler, Torsten [Klinikum Ernst von Bergmann, Department of Trauma and Orthopedic Surgery, Potsdam (Germany); Sparmann, Martin [Proendo, Orthopedic Surgery, Berlin (Germany); Charite - University Hospital, Berlin (Germany)

    2014-08-15

    The number of total hip arthroplasties is continuously rising. Although less invasive surgical techniques, sophisticated component design, and intraoperative navigation techniques have been introduced, the rate of peri- and postoperative complications, including dislocations, fractures, nerve palsies, and infections, is still a major clinical problem. Better patient outcome, faster recovery and rehabilitation, and shorter operation times therefore remain to be accomplished. A promising strategy is to use minimally invasive techniques in conjunction with modular implants, aimed at independently reconstructing femoral offset and leg length on the basis of highly accurate preoperative planning. Plain radiographs have clear limitations for the correct estimation of hip joint geometry and bone quality. Three-dimensional assessment based on computed tomography (CT) allows optimizing the choice and positions of implants and anticipating difficulties to be encountered during surgery. Postoperative CT is used to monitor operative translation and plays a role in arthroplastic quality management. Radiologists should be familiar with the needs of orthopedic surgeons in terms of CT acquisition, post-processing, and data transfer. The CT protocol should be optimized to enhance image quality and reduce radiation exposure. When dedicated orthopedic CT protocols and state-of-the-art scanner hardware are used, radiation exposure can be decreased to a level just marginally higher than that of conventional preoperative radiography. Surgeons and radiologists should use similar terminology to avoid misunderstanding and inaccuracies in the transfer of preoperative planning. (orig.)

  12. New concepts in preoperative imaging of anorectal malformation

    International Nuclear Information System (INIS)

    Taccone, A.; Delliacqua, A.; Marzoli, A.; Martucciello, G.; Jasonni, V.; Dodero, P.; Salomone, G.

    1992-01-01

    In this study of 14 patients with anorectal anomalies CT and MRI were employed for preoperative assessment. The use of a pressure enhanced water soluble enema via the colostomy proved to be an extremely efficient method for showing a fistula. MRI studies were enhanced by the use of vaseline oil and in one case this technique was used prior to surgery to provide important information by injecting through a perineal fistula. CT and axial MRI proved to be more valuable than sagittal MRI which is only useful for the length of the atretic segment. The authors consider that a combined approach using pressure enhanced water soluble enema and MRI will provide the most valuable preoperative information to plan a successful operative approach and enable an accurate prognostic evaluation of continence in these difficult and complex patients. (orig.)

  13. Binary Decision Trees for Preoperative Periapical Cyst Screening Using Cone-beam Computed Tomography.

    Science.gov (United States)

    Pitcher, Brandon; Alaqla, Ali; Noujeim, Marcel; Wealleans, James A; Kotsakis, Georgios; Chrepa, Vanessa

    2017-03-01

    Cone-beam computed tomographic (CBCT) analysis allows for 3-dimensional assessment of periradicular lesions and may facilitate preoperative periapical cyst screening. The purpose of this study was to develop and assess the predictive validity of a cyst screening method based on CBCT volumetric analysis alone or combined with designated radiologic criteria. Three independent examiners evaluated 118 presurgical CBCT scans from cases that underwent apicoectomies and had an accompanying gold standard histopathological diagnosis of either a cyst or granuloma. Lesion volume, density, and specific radiologic characteristics were assessed using specialized software. Logistic regression models with histopathological diagnosis as the dependent variable were constructed for cyst prediction, and receiver operating characteristic curves were used to assess the predictive validity of the models. A conditional inference binary decision tree based on a recursive partitioning algorithm was constructed to facilitate preoperative screening. Interobserver agreement was excellent for volume and density, but it varied from poor to good for the radiologic criteria. Volume and root displacement were strong predictors for cyst screening in all analyses. The binary decision tree classifier determined that if the volume of the lesion was >247 mm 3 , there was 80% probability of a cyst. If volume was cyst probability was 60% (78% accuracy). The good accuracy and high specificity of the decision tree classifier renders it a useful preoperative cyst screening tool that can aid in clinical decision making but not a substitute for definitive histopathological diagnosis after biopsy. Confirmatory studies are required to validate the present findings. Published by Elsevier Inc.

  14. Gait variability measurements in lumbar spinal stenosis patients: part B. Preoperative versus postoperative gait variability

    International Nuclear Information System (INIS)

    Papadakis, N C; Christakis, D G; Tzagarakis, G N; Chlouverakis, G I; Kampanis, N A; Stergiopoulos, K N; Katonis, P G

    2009-01-01

    The objective of this study was to assess the gait variability of lumbar spinal stenosis (LSS) patients and to evaluate its postoperative progression. The hypothesis was that LSS patients' preoperative gait variability in the frequency domain was higher than the corresponding postoperative. A tri-axial accelerometer sensor was used for the gait measurement and a spectral differential entropy algorithm was used to measure the gait variability. Twelve subjects with LSS were measured before and after surgery. Preoperative measurements were performed 2 days before surgery. Postoperative measurements were performed 6 and 12 months after surgery. Preoperative gait variability was higher than the corresponding postoperative. Also, in most cases, gait variability appeared to decrease throughout the year

  15. Value of three-dimensional volume rendering images in the assessment of the centrality index for preoperative planning in patients with renal masses.

    Science.gov (United States)

    Sofia, C; Magno, C; Silipigni, S; Cantisani, V; Mucciardi, G; Sottile, F; Inferrera, A; Mazziotti, S; Ascenti, G

    2017-01-01

    To evaluate the precision of the centrality index (CI) measurement on three-dimensional (3D) volume rendering technique (VRT) images in patients with renal masses, compared to its standard measurement on axial images. Sixty-five patients with renal lesions underwent contrast-enhanced multidetector (MD) computed tomography (CT) for preoperative imaging. Two readers calculated the CI on two-dimensional axial images and on VRT images, measuring it in the plane that the tumour and centre of the kidney were lying in. Correlation and agreement of interobserver measurements and inter-method results were calculated using intraclass correlation (ICC) coefficients and the Bland-Altman method. Time saving was also calculated. The correlation coefficients were r=0.99 (ppresent study showed that VRT and axial images produce almost identical values of CI, with the advantages of greater ease of execution and a time saving of almost 50% for 3D VRT images. In addition, VRT provides an integrated perspective that can better assist surgeons in clinical decision making and in operative planning, suggesting this technique as a possible standard method for CI measurement. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  16. Multidetector-row computed tomography for the preoperative evaluation of axillary nodal status in patients with breast cancer

    International Nuclear Information System (INIS)

    Ogasawara, Yutaka; Doihara, Hiroyoshi; Shiraiwa, Misaki; Ishihara, Setsuko

    2008-01-01

    We evaluated the effectiveness of multidetector-row computed tomography (MD-CT) for detecting axillary lymph nodal status (ALNS) in patients with breast cancer. We reviewed 42 patients with breast cancer. A metastatic lymph node on MD-CT was defined as oval or round, with more than 5 mm on the short axis. We evaluated ALNS preoperatively by both palpation and MD-CT findings and performed sentinel lymph node biopsy (SLNB) and complete axillary lymph node dissection (ALND). For establishing the ALNS, MD-CT showed a sensitivity of 76.9%, a specificity of 96.6%, and an accuracy of 90.5%. On the basis of the MD-CT findings, misdiagnosis was made in 4 of the 42 patients, only one of which was false positive. On the other hand, one patient with a histologically negative sentinel lymph node (SLN) result had metastasis only in a non-SLN. Preoperative MD-CT showed a positive node in this patient. Multidetector-row computed tomography assists in identifying women who require ALND without SLNB, with sufficient positive predictive value. False-negative detection by SLNB could be avoided with careful interpretation of the axillary lymph nodes shown by MD-CT. (author)

  17. Efficacy for preoperative screening of liver metastasis using computed tomography and ultrasonography in patients with colon cancer

    International Nuclear Information System (INIS)

    Kotanagi, Hitoshi; Sato, Emi; Murakoshi, Satoshi

    2000-01-01

    To establish an effective examination system for preoperative evaluation of liver metastasis by colon cancer, we analyzed the sensitivity, cost, and efficacy of computed tomography (CT) and ultrasonography (US) in 354 patients (including 63 patients with liver metastasis). The presence or absence of liver metastasis was ultimately diagnosed 5 years after the operation. The sensitivity, specificity, and accuracy for detecting liver metastasis were 65%, 94%, and 89%, respectively for CT, 57%, 97%, and 91% for US, and 65%, 93%, and 88% for CT plus US, and there were no significant differences among them. Neither CT nor US could fully detect intrahepatic cancer spread. The cost of detection of one patient with liver metastasis was 6,298 points for plain CT, 20,169 points for enhanced CT, and 5,773 points for US. It was concluded that CT plus US should not be employed for preoperative assessment of liver metastasis, because the detection rate of the two modalities is not significantly different, and these modalities do not compensate for each other's defects. From the standpoint of the cost-benefit relationship, US should be selected for preoperative evaluation of liver metastasis. (author)

  18. Persistent axial neck pain after cervical disc arthroplasty: a radiographic analysis.

    Science.gov (United States)

    Wagner, Scott C; Formby, Peter M; Kang, Daniel G; Van Blarcum, Gregory S; Cody, John P; Tracey, Robert W; Lehman, Ronald A

    2016-07-01

    There is very little literature examining optimal radiographic parameters for placement of cervical disc arthroplasty (CDA), nor is there substantial evidence evaluating the relationship between persistent postoperative neck pain and radiographic outcomes. We set out to perform a single-center evaluation of the radiographic outcomes, including associated complications, of CDA. This is a retrospective review. Two hundred eighty-five consecutive patients undergoing CDA were included in the review. The outcome measures were radiological parameters (preoperative facet arthrosis, disc height, CDA placement in sagittal and coronal planes, heterotopic ossification [HO] formation, etc.) and patient outcomes (persistent pain, recurrent pain, new-onset pain, etc.). We performed a retrospective review of all patients from a single military tertiary medical center from August 2008 to August 2012 undergoing CDA. Preoperative, immediate postoperative, and final follow-up films were evaluated. The clinical outcomes and complications associated with the procedure were also examined. The average radiographic follow-up was 13.5 months and the rate of persistent axial neck pain was 17.2%. For patients with persistent neck pain, the rate of HO formation per level studied was 22.6%, whereas the rate was significantly lower for patients without neck pain (11.7%, p=.03). There was no significant association between the severity of HO and the presence of neck pain. Patients with a preoperative diagnosis of cervicalgia, compared to those without cervicalgia, were significantly more likely to experience continued neck pain postoperatively (28.6% vs. 13.1%, p=.01). There were no differences in preoperative facet arthrosis, pre- or postoperative disc height, segmental range of motion, or placement of the device relative to the posterior edge of the vertebral body.However, patients with implants more centered between the uncovertebral joints were more likely to experience posterior neck pain

  19. The preoperative imaging evaluation for cochlear implantation

    International Nuclear Information System (INIS)

    Liu Zhonglin; Wang Zhenchang; Fu Lin; Li Yong; Xian Junfang; Yang Bentao; Lan Baosen; Li Yongxin; Zheng Jun; Song Yan; Liu Bo; Chen Xueqing; He Haili

    2006-01-01

    Objective: To analyze CT and MRI findings of temporal bone and to evaluate preoperative diagnostic value for cochlear implantation. Methods: One hundred and sixty candidates for cochlear implantation were examined with axial CT scan, 64 of them also with coronal CT scan, and 119 patients with MRI. Results: All of 320 ears were well-aerated, and 206 ears had mastoid cavities extended posteriorly to the sigmoid sinus. The length from posterior-lateral tympanic wall to the outer cortex was (2.34±0.42) mm (left side) and (2.25±0.40) mm (right side) (U=1.887, P 1 and T 2 signal on MRI. The congenital malformations of inner ear occurred in 67 ears, including complete dysplasia in 1 ear, cochlear hypodysplasia in 6 ears, Mondini deformation in 5 ears, enlarged vestibular aqueduct in 40 ears, dysplastic semicircular canal and the vestibulae in 10 ears, and narrowing of internal auditory canal in 5 ears. Conclusion: Preoperative imaging examinations can provide critical information to ensure successful cochlear' implantation. (authors)

  20. Computerized axial tomography : the tool in osseointegrated dental implants

    International Nuclear Information System (INIS)

    Fernandez-Lopez, Otton

    2002-01-01

    Failure rates in rehabilitations with osseointegrated implants are handled through appropriate radiographic preoperative planning. The appropriate length of the implant without running the risk of a perforation of vital structures, has been determined by a radiographic diagnosis. Computerized and conventional axial tomography have proved to be invaluable elements for pre-surgical evaluation. A radiologic guidance is elaborated to perform a computerized axial tomography (CT) of maxillary bones in totally edentulous patients. Surgical guides are constructed from a wax-up emanated from the information of the CT. The CT has proven to be an radiographic indispensable element to achieve the surgical-prosthetic success in osseointegrated dental implants. The CT has allowed the realization of a precise wax-up for making of surgical guide and a precise temporary prostheses in positioning of osseointegrated implants, with the consequent saving time and money for the rehabilitator and patient [es

  1. Patient-specific instrumentation for total knee arthroplasty does not match the pre-operative plan as assessed by intra-operative computer-assisted navigation.

    Science.gov (United States)

    Scholes, Corey; Sahni, Varun; Lustig, Sebastien; Parker, David A; Coolican, Myles R J

    2014-03-01

    The introduction of patient-specific instruments (PSI) for guiding bone cuts could increase the incidence of malalignment in primary total knee arthroplasty. The purpose of this study was to assess the agreement between one type of patient-specific instrumentation (Zimmer PSI) and the pre-operative plan with respect to bone cuts and component alignment during TKR using imageless computer navigation. A consecutive series of 30 femoral and tibial guides were assessed in-theatre by the same surgeon using computer navigation. Following surgical exposure, the PSI cutting guides were placed on the joint surface and alignment assessed using the navigation tracker. The difference between in-theatre data and the pre-operative plan was recorded and analysed. The error between in-theatre measurements and pre-operative plan for the femoral and tibial components exceeded 3° for 3 and 17% of the sample, respectively, while the error for total coronal alignment exceeded 3° for 27% of the sample. The present results indicate that alignment with Zimmer PSI cutting blocks, assessed by imageless navigation, does not match the pre-operative plan in a proportion of cases. To prevent unnecessary increases in the incidence of malalignment in primary TKR, it is recommended that these devices should not be used without objective verification of alignment, either in real-time or with post-operative imaging. Further work is required to identify the source of discrepancies and validate these devices prior to routine use. II.

  2. Can pre-operative axial CT imaging predict syndesmosis instability in patients sustaining ankle fractures? Seven years' experience in a tertiary trauma center

    Energy Technology Data Exchange (ETDEWEB)

    Yeung, Tsz Wai; Chan, Chung Yan Grace; Chan, Wun Cheung Samuel; Yuen, Ming Keung [Tuen Mun Hospital, Department of Radiology, Tuen Mun (China); Yeung, Yuk Nam [Tune Mun Hospital, Department of Orthopaedics and Traumatology, Tuen Mun (China)

    2015-06-01

    The purpose of this study is to explore the diagnostic accuracy of CT measurements in predicting syndesmosis instability of injured ankle, with correlation to operative findings. From July 2006 to June 2013, 123 patients presented to a single tertiary hospital who received pre-operative CT for ankle fractures were retrospectively reviewed. All patients underwent open reduction and internal fixation for fractures and intra-operative syndesmosis integrity tests. The morphology of incisura fibularis was categorized as deep or shallow. The tibiofibular distance (TFD) between the medial border of the fibula and the nearest point of the lateral border of tibia were measured at anterior (aTFD), middle (mTFD), posterior (pTFD), and maximal (maxTFD) portions across the syndesmosis on axial CT images at 10 mm proximal to the tibial plafond. Statistical analysis was performed with independent samples t test and ROC curve analysis. Intraobserver reproducibility and inter-observers agreement were also evaluated. Of the 123 patients, 39 (31.7 %) were operatively diagnosed with syndesmosis instability. No significant difference of incisura fibularis morphology (deep or shallow) and TFDs was demonstrated respective to genders. The axial CT measurements were significantly higher in ankles diagnosed with syndesmosis instability than the group without (maxTFD means 7.2 ± 2.96 mm vs. 4.6 ± 1.4 mm, aTFD mean 4.9 ± 3.7 mm vs. 1.8 ± 1.4 mm, mTFD mean 5.3 ± 2.4 mm vs. 3.2 ± 1.6 mm, pTFD mean 5.3 ± 1.8 mm vs. 4.1 ± 1.3 mm, p < 0.05). Their respective cutoff values with best sensitivity and specificity were calculated; the aTFD (AUC 0.798) and maxTFD (AUC 0.794) achieved the highest diagnostic accuracy. The optimal cutoff levels were aTFD = 4 mm (sensitivity, 56.4 %; specificity, 91.7 %) and maxTFD = 5.65 mm (sensitivity, 74.4 %; specificity, 79.8 %). The inter-observer agreement was good for all aTFD, mTFD, pTFD, and maxTFD measurements (ICC 0.959, 0.799, 0.783, and 0.865). The ICC

  3. Can pre-operative axial CT imaging predict syndesmosis instability in patients sustaining ankle fractures? Seven years' experience in a tertiary trauma center

    International Nuclear Information System (INIS)

    Yeung, Tsz Wai; Chan, Chung Yan Grace; Chan, Wun Cheung Samuel; Yuen, Ming Keung; Yeung, Yuk Nam

    2015-01-01

    The purpose of this study is to explore the diagnostic accuracy of CT measurements in predicting syndesmosis instability of injured ankle, with correlation to operative findings. From July 2006 to June 2013, 123 patients presented to a single tertiary hospital who received pre-operative CT for ankle fractures were retrospectively reviewed. All patients underwent open reduction and internal fixation for fractures and intra-operative syndesmosis integrity tests. The morphology of incisura fibularis was categorized as deep or shallow. The tibiofibular distance (TFD) between the medial border of the fibula and the nearest point of the lateral border of tibia were measured at anterior (aTFD), middle (mTFD), posterior (pTFD), and maximal (maxTFD) portions across the syndesmosis on axial CT images at 10 mm proximal to the tibial plafond. Statistical analysis was performed with independent samples t test and ROC curve analysis. Intraobserver reproducibility and inter-observers agreement were also evaluated. Of the 123 patients, 39 (31.7 %) were operatively diagnosed with syndesmosis instability. No significant difference of incisura fibularis morphology (deep or shallow) and TFDs was demonstrated respective to genders. The axial CT measurements were significantly higher in ankles diagnosed with syndesmosis instability than the group without (maxTFD means 7.2 ± 2.96 mm vs. 4.6 ± 1.4 mm, aTFD mean 4.9 ± 3.7 mm vs. 1.8 ± 1.4 mm, mTFD mean 5.3 ± 2.4 mm vs. 3.2 ± 1.6 mm, pTFD mean 5.3 ± 1.8 mm vs. 4.1 ± 1.3 mm, p < 0.05). Their respective cutoff values with best sensitivity and specificity were calculated; the aTFD (AUC 0.798) and maxTFD (AUC 0.794) achieved the highest diagnostic accuracy. The optimal cutoff levels were aTFD = 4 mm (sensitivity, 56.4 %; specificity, 91.7 %) and maxTFD = 5.65 mm (sensitivity, 74.4 %; specificity, 79.8 %). The inter-observer agreement was good for all aTFD, mTFD, pTFD, and maxTFD measurements (ICC 0.959, 0.799, 0.783, and 0.865). The ICC

  4. Impact of Cervical Sagittal Alignment on Axial Neck Pain and Health-related Quality of Life After Cervical Laminoplasty in Patients With Cervical Spondylotic Myelopathy or Ossification of the Posterior Longitudinal Ligament: A Prospective Comparative Study.

    Science.gov (United States)

    Fujiwara, Hiroyasu; Oda, Takenori; Makino, Takahiro; Moriguchi, Yu; Yonenobu, Kazuo; Kaito, Takashi

    2018-05-01

    This is prospective observational study. To prospectively investigate the correlation among axial neck pain; a newly developed patient-based quality of life outcome measure, the Japanese Orthopaedic Association Cervical Myelopathy Evaluation Questionnaire (JOACMEQ); and cervical sagittal alignment after open-door laminoplasty for cervical myelopathy. Many studies have focused on postoperative axial neck pain after laminoplasty. However, the correlation among cervical sagittal alignment, neck pain, and JOACMEQ has not been investigated. In total, 57 consecutive patients treated by open-door laminoplasty for cervical myelopathy were included (mean age, 63.7 y; 15 women and 42 men) and divided into 2 groups according to diagnosis [cervical spondylotic myelopathy (CSM) group: 35 patients, and ossification of the posterior longitudinal ligament (OPLL) group: 22 patients]. JOA score, a subdomain of cervical spine function (CSF) in the JOACMEQ, and the visual analog scale for axial neck pain were assessed preoperatively and 12 months postoperatively. Radiographic cervical sagittal parameters were measured by C2 sagittal vertical axis (C2 SVA), C2-C7 lordosis, C7 sagittal slope (C7 slope), and range of motion. C2 SVA values in both groups shifted slightly anteriorly between preoperative and 12-month postoperative measurements (CSM: +19.7±10.9 mm; OPLL: +22.1±13.4 mm vs. CSM: +23.2±16.1 mm; OPLL: +28.7±15.4 mm, respectively). Postoperative axial neck pain in the OPLL group showed strong negative correlations with C2 SVA and C7 slope. Strong negative correlations were found between axial neck pain and CSF in both the preoperative CSM and OPLL groups (CSM: r=-0.45, P=0.01; OPLL: r=-0.61, Ppain and CSF in the postoperative OPLL group (r=-0.51, P=0.05). This study demonstrated a significant negative correlation between neck pain and CSF in both the CSM and OPLL groups preoperatively and in the OPLL group postoperatively. Radiographic cervical sagittal alignment

  5. Preoperative computer tomography evaluation in transcatheter aortic valve replacement (TAVI)

    International Nuclear Information System (INIS)

    Groudeva, V.; Stoynova, V.; Trendafilova, D.; Dzhorgova, Y.; Nachev, G.

    2014-01-01

    Transcatheter aortic valve replacement is rapidly emerging technique alternative to surgery in high risk patients. Imaging and especially computer tomography is important in preoperative assessment of the aortic ring and the prosthetic valve choice. The aim of this study is to share authors initial experience in CT assessment of the aortic ring prior to Transcatheter aortic valve replacement. 49 patients (mean age 76,55) underwent 320 rows MDCT (Acquilon One) prior TAVI. Protocol involved scanning from thoracic inlet to common femoral arteries. Aortic root size, aortic diameter at the level of coronary sinuses and the sinotubular junction and distance to coronary ostia were evaluated on a Vitrea work station. MDCT established maximal aortic ring diameter from 18 to 31 mm mean 25,04 mm while the lesser rate was from 16 to 21 mm. Accordingly positioned prostheses were in 34,75% No. 23, in 49% - No. 26 and in16,3% - No. 29. MDCT is crucial in aortic valve assessment prior to TAVI in experienced hands and multidisciplinary team. (authors) Key words: TRANSCATHETER AORTIC VALVE REPLACEMENT (TAVI). MDCT AORTIC VALVE ASSESSMENT

  6. The Nucleon Axial Form Factor and Staggered Lattice QCD

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Aaron Scott [Chicago U.

    2017-01-01

    The study of neutrino oscillation physics is a major research goal of the worldwide particle physics program over the upcoming decade. Many new experiments are being built to study the properties of neutrinos and to answer questions about the phenomenon of neutrino oscillation. These experiments need precise theoretical cross sections in order to access fundamental neutrino properties. Neutrino oscillation experiments often use large atomic nuclei as scattering targets, which are challenging for theorists to model. Nuclear models rely on free-nucleon amplitudes as inputs. These amplitudes are constrained by scattering experiments with large nuclear targets that rely on the very same nuclear models. The work in this dissertation is the rst step of a new initiative to isolate and compute elementary amplitudes with theoretical calculations to support the neutrino oscillation experimental program. Here, the eort focuses on computing the axial form factor, which is the largest contributor of systematic error in the primary signal measurement process for neutrino oscillation studies, quasielastic scattering. Two approaches are taken. First, neutrino scattering data on a deuterium target are reanalyzed with a model-independent parametrization of the axial form factor to quantify the present uncertainty in the free-nucleon amplitudes. The uncertainties on the free-nucleon cross section are found to be underestimated by about an order of magnitude compared to the ubiquitous dipole model parametrization. The second approach uses lattice QCD to perform a rst-principles computation of the nucleon axial form factor. The Highly Improved Staggered Quark (HISQ) action is employed for both valence and sea quarks. The results presented in this dissertation are computed at physical pion mass for one lattice spacing. This work presents a computation of the axial form factor at zero momentum transfer, and forms the basis for a computation of the axial form factor momentum dependence

  7. Preoperative diagnosis of Amyand's hernia by ultrasound and computed tomography

    Directory of Open Access Journals (Sweden)

    Husam Vehbi

    2016-06-01

    Full Text Available Inguinal hernia is the most common seen groin hernias which mostly contain bowel. The incidence of vermiform appendix in an inguinal hernia is seen in 1% of all inguinal hernia. This is known as Amyand's hernia. Appendix within a hernia can be normal or complicated by appendicitis. Most of these cases are not diagnosed preoperatively and managed during surgery. Preoperative diagnosis of these cases is so rare. Very few cases have been reported so far.In our case, we diagnosed an inflamed appendix in a 49 years old female within right inguinal hernia by using ultrasound and confirmed it by CT scan. Keywords: Amyand's hernia, Appendicitis

  8. Preoperative magnetic resonance and intraoperative ultrasound fusion imaging for real-time neuronavigation in brain tumor surgery.

    Science.gov (United States)

    Prada, F; Del Bene, M; Mattei, L; Lodigiani, L; DeBeni, S; Kolev, V; Vetrano, I; Solbiati, L; Sakas, G; DiMeco, F

    2015-04-01

    Brain shift and tissue deformation during surgery for intracranial lesions are the main actual limitations of neuro-navigation (NN), which currently relies mainly on preoperative imaging. Ultrasound (US), being a real-time imaging modality, is becoming progressively more widespread during neurosurgical procedures, but most neurosurgeons, trained on axial computed tomography (CT) and magnetic resonance imaging (MRI) slices, lack specific US training and have difficulties recognizing anatomic structures with the same confidence as in preoperative imaging. Therefore real-time intraoperative fusion imaging (FI) between preoperative imaging and intraoperative ultrasound (ioUS) for virtual navigation (VN) is highly desirable. We describe our procedure for real-time navigation during surgery for different cerebral lesions. We performed fusion imaging with virtual navigation for patients undergoing surgery for brain lesion removal using an ultrasound-based real-time neuro-navigation system that fuses intraoperative cerebral ultrasound with preoperative MRI and simultaneously displays an MRI slice coplanar to an ioUS image. 58 patients underwent surgery at our institution for intracranial lesion removal with image guidance using a US system equipped with fusion imaging for neuro-navigation. In all cases the initial (external) registration error obtained by the corresponding anatomical landmark procedure was below 2 mm and the craniotomy was correctly placed. The transdural window gave satisfactory US image quality and the lesion was always detectable and measurable on both axes. Brain shift/deformation correction has been successfully employed in 42 cases to restore the co-registration during surgery. The accuracy of ioUS/MRI fusion/overlapping was confirmed intraoperatively under direct visualization of anatomic landmarks and the error was surgery and is less expensive and time-consuming than other intraoperative imaging techniques, offering high precision and

  9. Changes in computed tomography features following preoperative chemotherapy for nephroblastoma: relation to histopathological classification

    International Nuclear Information System (INIS)

    Olsen, Oeystein E.; Jeanes, Annmarie C.; Roebuck, Derek J.; Owens, Catherine M.; Sebire, Neil J.; Risdon, Rupert A.; Michalski, Anthony J.

    2004-01-01

    The objective of this study is to assess computed tomography (CT) changes, both volume estimates and subjective features, following preoperative chemotherapy for nephroblastoma (Wilms' tumour) in patients treated on the United Kingdom Children's Cancer Study Group Wilms' Tumour Study-3 (UKW-3) protocol and to compare CT changes and histopathological classification. Twenty-one nephroblastomas in 15 patients treated on UKW-3 were included. All patients were examined by CT before and after preoperative chemotherapy treatment. CT images were reviewed (estimated volume change and subjectively assessed features). CT changes were compared to histopathological classification. Of the 21 tumours, all five high-risk tumours decreased in volume following chemotherapy (median -79%; range -37 to -91%). The sole low-risk tumour decreased in volume by 98%. Ten intermediate-risk tumours decreased in volume (median -72%; range -6 to -98%) and five intermediate-risk tumours increased (median +110%; range +11 to +164%). None of the five high-risk tumours, compared to 15/16 intermediate or low-risk tumours, became less dense and/or more homogeneous, or virtually disappeared, following chemotherapy. Volume change following chemotherapy did not relate to histopathological risk group. Changes in subjectively assessed qualitative CT features were more strongly related to histopathological risk group. (orig.)

  10. Cladding axial elongation models for FRAP-T6

    International Nuclear Information System (INIS)

    Shah, V.N.; Carlson, E.R.; Berna, G.A.

    1983-01-01

    This paper presents a description of the cladding axial elongation models developed at the Idaho National Engineering Laboratory (INEL) for use by the FRAP-T6 computer code in analyzing the response of fuel rods during reactor transients in light water reactors (LWR). The FRAP-T6 code contains models (FRACAS-II subcode) that analyze the structural response of a fuel rod including pellet-cladding-mechanical-interaction (PCMI). Recently, four models were incorporated into FRACAS-II to calculate cladding axial deformation: (a) axial PCMI, (b) trapped fuel stack, (c) fuel relocation, and (d) effective fuel thermal expansion. Comparisons of cladding axial elongation measurements from two experiments with the corresponding FRAP-T6 calculations are presented

  11. Precision resection of intra-axial CNS lesions by CT-based stereotactic craniotomy and computer monitored CO2 laser

    International Nuclear Information System (INIS)

    Kelly, P.J.; Kall, B.; Goerss, S.; Alker, G.J. Jr.

    1983-01-01

    This report describes an open stereotactic technique by which a tumour volume reconstructed in stereotactic space from CT data is removed by stereotactic CO 2 laser vaporization. The position of the laser beam in relation to the tumour outlines is monitored by computer and displayed to the surgeon on a graphics display terminal in the operating room. Twenty-six (26) of these procedures have been performed on twenty-four (24) patients with deep-seated intra-axial neoplasms (23) and arteriovenous malformation. Post-operative CT scanning revealed no evidence of contrast enhancing lesions in nineteen (19) patients while a small amount of residual tumour was noted in five (5) patients post-operatively. This method has proven itself valuable for maintaining three-dimensional surgical orientation for the resection of intra-axial neoplasms from neurologically important areas. (Author)

  12. Reproducibility of Abdominal Aortic Aneurysm Diameter Measurement and Growth Evaluation on Axial and Multiplanar Computed Tomography Reformations

    International Nuclear Information System (INIS)

    Dugas, Alexandre; Therasse, Éric; Kauffmann, Claude; Tang, An; Elkouri, Stephane; Nozza, Anna; Giroux, Marie-France; Oliva, Vincent L.; Soulez, Gilles

    2012-01-01

    Purpose: To compare different methods measuring abdominal aortic aneurysm (AAA) maximal diameter (Dmax) and its progression on multidetector computed tomography (MDCT) scan. Materials and Methods: Forty AAA patients with two MDCT scans acquired at different times (baseline and follow-up) were included. Three observers measured AAA diameters by seven different methods: on axial images (anteroposterior, transverse, maximal, and short-axis views) and on multiplanar reformation (MPR) images (coronal, sagittal, and orthogonal views). Diameter measurement and progression were compared over time for the seven methods. Reproducibility of measurement methods was assessed by intraclass correlation coefficient (ICC) and Bland–Altman analysis. Results: Dmax, as measured on axial slices at baseline and follow-up (FU) MDCTs, was greater than that measured using the orthogonal method (p = 0.046 for baseline and 0.028 for FU), whereas Dmax measured with the orthogonal method was greater those using all other measurement methods (p-value range: <0.0001–0.03) but anteroposterior diameter (p = 0.18 baseline and 0.10 FU). The greatest interobserver ICCs were obtained for the orthogonal and transverse methods (0.972) at baseline and for the orthogonal and sagittal MPR images at FU (0.973 and 0.977). Interobserver ICC of the orthogonal method to document AAA progression was greater (ICC = 0.833) than measurements taken on axial images (ICC = 0.662–0.780) and single-plane MPR images (0.772–0.817). Conclusion: AAA Dmax measured on MDCT axial slices overestimates aneurysm size. Diameter as measured by the orthogonal method is more reproducible, especially to document AAA progression.

  13. CT evaluation of preoperative cochlear implantation cochlear implantation

    International Nuclear Information System (INIS)

    Tan Xiuzhong; Zhong Lansheng; Lan Bowen; Huang Yaosheng; Du Baowen; Zhu Jian

    2004-01-01

    Objective: To evaluate CT scan as a preoperative evaluation for cochlear implantation candidates. Methods: Axial high-resolution temporal bone CT and three-dimensional reconstruction of inner ear were performed in 93 patients with sensorineural hearing loss. results: Among 81 patients with congenital sensorineural deafness, Mondini malformation was seen in 7 case (13 ears); large vestibular aqueduct syndrome (LVAS) was revealed in 5 cases (8 ears); and inner ear ossification was found in 1 case (2 ears). In 1 case (2 ears) of inner ear fibrosis, reduced cochlear signal was noted on MRI but no unremarkable findings was shown on CT scan, however, in the operation, the device could not inserted into the basal circle of the cochlea, due to fibrous obliteration. In 12 patients with post-speech deafness, chronic suppurative tympanitis was seen in 2 cases (4 ears), and inner ear ossification was revealed in 1 case (2 ears). Conclusion: CT plays an indispensable role in the pre-operative evaluation of cochlear implantation. T 2 -weighted FSE-MRI of the inner ear is a useful complementary to CT scan. (authors)

  14. Computer-assisted preoperative simulation for positioning and fixation of plate in 2-stage procedure combining maxillary advancement by distraction technique and mandibular setback surgery

    Directory of Open Access Journals (Sweden)

    Hideyuki Suenaga

    2016-01-01

    Conclusion: The implementation of the computer-assisted preoperative simulation for the positioning and fixation of plate in 2-stage orthognathic procedure using distraction technique and mandibular setback surgery yielded good results.

  15. Magnetic resonance cisternography for preoperative evaluation of arachnoid cysts

    Energy Technology Data Exchange (ETDEWEB)

    Awaji, M. [Niigata University, Department of Radiology, Faculty of Medicine, Niigata (Japan); Okamoto, K. [Niigata University, Center for Integrated Human Brain Science, Brain Research Institute, Niigata (Japan); Nishiyama, K. [Niigata University, Department of Neurosurgery, Brain Research Institute, Niigata (Japan)

    2007-09-15

    With a high likelihood of clinical improvement and low rates of complications, minimally invasive neuroendoscopic surgery is becoming the treatment of choice for symptomatic or growing arachnoid cysts. In neuroendoscopic surgery, visualization of anatomical landmarks is essential in achieving successful fenestration without complications. Because of the restricted visual field in neuroendoscopic surgery, preoperative anatomical assessment is very helpful. Magnetic resonance cisternography (MRC) with high spatial resolution and contrast, using for example 3-D Fourier transformation constructive interference in steady state (CISS) or fast imaging employing steady-state acquisition (FIESTA) sequences, is able to detect the arachnoid cyst wall and neighboring anatomical structures as the anatomical landmarks. We retrospectively reviewed T2-weighted (T2-W) fast spin-echo images, and the MRC and intraoperative findings. Axial and coronal T2-W images (6 and 3 mm thickness, respectively) and axial and coronal 0.8 mm thick MRC images with CISS or FIESTA were obtained from four patients with arachnoid cysts treated by neuroendoscopic surgery. Intraoperative findings were reviewed on videotape recorded during the procedures. At the brain surface, the arachnoid cyst wall could be detected clearly in any of the four patients on MRC images, and was only partly seen in the fourth patient T2-W images. Adjacent important anatomical structures including vessels and cranial nerves, and an enough space for cystocisternostomy were identified on MRC images, and the findings were consistent with the findings during neuroendoscopic surgery. Preoperative identification of the arachnoid cyst wall and surrounding anatomical structures by MRC may help avoid complications and allow safer neuroendoscopic surgery. (orig.)

  16. Development of a miniaturized mass-flow meter for an axial flow blood pump based on computational analysis.

    Science.gov (United States)

    Kosaka, Ryo; Nishida, Masahiro; Maruyama, Osamu; Yamane, Takashi

    2011-09-01

    In order to monitor the condition of patients with implantable left ventricular assist systems (LVAS), it is important to measure pump flow rate continuously and noninvasively. However, it is difficult to measure the pump flow rate, especially in an implantable axial flow blood pump, because the power consumption has neither linearity nor uniqueness with regard to the pump flow rate. In this study, a miniaturized mass-flow meter for discharged patients with an implantable axial blood pump was developed on the basis of computational analysis, and was evaluated in in-vitro tests. The mass-flow meter makes use of centrifugal force produced by the mass-flow rate around a curved cannula. An optimized design was investigated by use of computational fluid dynamics (CFD) analysis. On the basis of the computational analysis, a miniaturized mass-flow meter made of titanium alloy was developed. A strain gauge was adopted as a sensor element. The first strain gauge, attached to the curved area, measured both static pressure and centrifugal force. The second strain gauge, attached to the straight area, measured static pressure. By subtracting the output of the second strain gauge from the output of the first strain gauge, the mass-flow rate was determined. In in-vitro tests using a model circulation loop, the mass-flow meter was compared with a conventional flow meter. Measurement error was less than ±0.5 L/min and average time delay was 0.14 s. We confirmed that the miniaturized mass-flow meter could accurately measure the mass-flow rate continuously and noninvasively.

  17. Investigation of axial power gradients near a control rod tip

    Energy Technology Data Exchange (ETDEWEB)

    Loberg, John, E-mail: John.Loberg@fysast.uu.se [Uppsala University, Department of Physics and Astronomy, Division of Applied Nuclear Physics, Box 525, SE-75120 Uppsala (Sweden); Osterlund, Michael, E-mail: Michael.Osterlund@fysast.uu.se [Uppsala University, Department of Physics and Astronomy, Division of Applied Nuclear Physics, Box 525, SE-75120 Uppsala (Sweden); Bejmer, Klaes-Hakan, E-mail: Klaes-Hakan.Bejmer@vattenfall.com [Vattenfall Nuclear Fuel AB, Jaemtlandsgatan 99, 162 60 Vaellingby, Stockholm (Sweden); Blomgren, Jan, E-mail: Jan.Blomgren@vattenfall.com [Vattenfall Nuclear Fuel AB, Jaemtlandsgatan 99, 162 60 Vaellingby, Stockholm (Sweden); Kierkegaard, Jesper, E-mail: Jesper.Kierkegaar@vattenfall.com [Vattenfall Nuclear Fuel AB, Jaemtlandsgatan 99, 162 60 Vaellingby, Stockholm (Sweden)

    2011-07-15

    Highlights: > Pin power gradients near BWR control rod tips have been investigated. > A control rod tip is modeled in MCNP and compared to simplified 2D/3D geometry. > Small nodes increases pin power gradients; standard nodes underestimates gradients. > The MCNP results are validated against axial gamma scan of a controlled fuel pin. - Abstract: Control rod withdrawal in BWRs induces large power steps in the adjacent fuel assemblies. This paper investigates how well a 2D/3D method, e.g., CASMO5/SIMULATE5 computes axial pin power gradients adjacent to an asymmetrical control-rod tip in a BWR. The ability to predict pin power gradients accurately is important for safety considerations whereas large powers steps induced by control rod withdrawal can cause Pellet Cladding Interaction. The computation of axial pin power gradients axially around a control rod tip is a challenging task for any nodal code. On top of that, asymmetrical control rod handles are present in some BWR designs. The lattice code CASMO requires diagonal symmetry of all control rod parts. This introduces an error in computed pin power gradients that has been evaluated by Monte Carlo calculations. The results show that CASMO5/SIMULATE5, despite the asymmetrical control rod handle, is able to predict the axial pin power gradient within 1%/cm for axial nodal sizes of 15-3.68 cm. However, a nodal size of 3.68 cm still causes underestimations of pin power gradients compared with 1 cm nodes. Furthermore, if conventional node sizes are used, {approx}15 cm, pin power gradients can be underestimated by over 50% compared with 1 cm nodes. The detailed axial pin power profiles from MCNP are corroborated by measured gamma scan data on fuel rods irradiated adjacent to control rods.

  18. Investigation of axial power gradients near a control rod tip

    International Nuclear Information System (INIS)

    Loberg, John; Osterlund, Michael; Bejmer, Klaes-Hakan; Blomgren, Jan; Kierkegaard, Jesper

    2011-01-01

    Highlights: → Pin power gradients near BWR control rod tips have been investigated. → A control rod tip is modeled in MCNP and compared to simplified 2D/3D geometry. → Small nodes increases pin power gradients; standard nodes underestimates gradients. → The MCNP results are validated against axial gamma scan of a controlled fuel pin. - Abstract: Control rod withdrawal in BWRs induces large power steps in the adjacent fuel assemblies. This paper investigates how well a 2D/3D method, e.g., CASMO5/SIMULATE5 computes axial pin power gradients adjacent to an asymmetrical control-rod tip in a BWR. The ability to predict pin power gradients accurately is important for safety considerations whereas large powers steps induced by control rod withdrawal can cause Pellet Cladding Interaction. The computation of axial pin power gradients axially around a control rod tip is a challenging task for any nodal code. On top of that, asymmetrical control rod handles are present in some BWR designs. The lattice code CASMO requires diagonal symmetry of all control rod parts. This introduces an error in computed pin power gradients that has been evaluated by Monte Carlo calculations. The results show that CASMO5/SIMULATE5, despite the asymmetrical control rod handle, is able to predict the axial pin power gradient within 1%/cm for axial nodal sizes of 15-3.68 cm. However, a nodal size of 3.68 cm still causes underestimations of pin power gradients compared with 1 cm nodes. Furthermore, if conventional node sizes are used, ∼15 cm, pin power gradients can be underestimated by over 50% compared with 1 cm nodes. The detailed axial pin power profiles from MCNP are corroborated by measured gamma scan data on fuel rods irradiated adjacent to control rods.

  19. Axial distribution of absorbed doses in fast neutron field at the RB reactor

    International Nuclear Information System (INIS)

    Sokcic-Kostic, M.; Pesic, M.; Antic, D.; Ninkovic, M.

    1988-11-01

    The coupled fast thermal system CFTS at the RB reactor is created for obtaining fast neutron fields. The axial distribution of fast neutron flux density in its second configuration (CFTS-2) is measured. The axial distribution of absorbed doses is computed on the basis of mentioned experimental results. At the end these experimental and computed results are given. (Author)

  20. Dynamic control of knee axial deformities

    Directory of Open Access Journals (Sweden)

    E. E. Malyshev

    2013-01-01

    Full Text Available The authors have evaluated the clinical examination of the patients with axial malalignments in the knee by the original method and device which was named varovalgometer. The measurements were conducted by tension of the cord through the spina iliaca anterior superior and the middle of the lower pole of patella. The deviation of the center of the ankle estimated by metal ruler which was positioned perpendicular to the lower leg axis on the level of the ankle joint line. The results of comparison of our method and computer navigation in 53 patients during the TKA show no statistically significant varieties but they differ by average 5° of valgus in clinical examination in comparison with mechanical axis which was identified by computer navigation. The dynamic control of axial malalignment can be used in clinical practice for estimation of the results of treatment of pathology with axial deformities in the knee; for the control of reduction and secondary displacement of the fractures around the knee; for assessment of instability; in planning of correctional osteotomies and intraoperative control of deformity correction; for estimation of Q angle in subluxation and recurrent dislocation of patella; in planning of TKA; during the growth of child it allows to assess the progression of deformity.

  1. Axial magnetic field produced by axially and radially magnetized permanent rings

    International Nuclear Information System (INIS)

    Peng, Q.L.; McMurry, S.M.; Coey, J.M.D.

    2004-01-01

    Axial magnetic fields produced by axially and radially magnetized permanent magnet rings were studied. First, the axial magnetic field produced by a current loop is introduced, from which the axial field generated by an infinitely thin solenoid and by an infinitely thin current disk can be derived. Then the axial fields produced by axially and by radially magnetized permanent magnet rings can be obtained. An analytic formula for the axial fields produced by two axially magnetized rings is given. A permanent magnet with a high axial gradient field is fabricated, the measured results agree with the theoretical calculation very well. As an example, the axial periodic field produced by an arrangement of alternating axially and radially magnetized rings has been discussed

  2. Measurements of computed tomography dose index for axial and spiral CT scanners

    International Nuclear Information System (INIS)

    Breiki, G; Abbas, Y.; Diab, H.M.; Gomaa, M

    2007-01-01

    The energy deposited in the patient by the rotating x-ray beam in computed tomography produces more uniform absorbed dose values within the section of imaged tissue than those produced in conventional radiological procedures. The dose values within a specific section are determined by factors such as voltage, current, scan field, rotation angle, filtration, collimation, and section thickness and spacing. This study is a part of extensive project, aiming to investigate practice of computed tomography at various hospitals and to implement a Reference Dose Levels (RDLs) to routine CT examinations in Egypt. The dosimetric quantities proposed in the European Guidelines (EG) for CT are weighted computed tomography dose index (CTDI w ) for a single slice and dose-length product (DLP) for a complete examination. Patient-related data as well as technical parameters for head, chest, abdomen and pelvis examinations were collected for seven CT scanners in public and private hospitals.Dose measurements were performed for both axial and spiral models for a range of CT examinations using CT dosimetry head and body phantoms, and ion chamber designed for CT dosimetry. The determined CTDI w and DLP values were compared with the European Commission reference dose levels (ECRDLs) and also with some international survey results. Mean values of CTDI w had a range of 36-69 m Gy with average 55 m Gy for head, and 11-35 mGy with average 23 mGy for chest, abdomen and pelvis examinations. The current reference CTDI w values are 60 m Gy for adult head and 25 m Gy for adult Abdomen

  3. Diagnostic accuracy of a volume-rendered computed tomography movie and other computed tomography-based imaging methods in assessment of renal vascular anatomy for laparoscopic donor nephrectomy.

    Science.gov (United States)

    Yamamoto, Shingo; Tanooka, Masao; Ando, Kumiko; Yamano, Toshiko; Ishikura, Reiichi; Nojima, Michio; Hirota, Shozo; Shima, Hiroki

    2009-12-01

    To evaluate the diagnostic accuracy of computed tomography (CT)-based imaging methods for assessing renal vascular anatomy, imaging studies, including standard axial CT, three-dimensional volume-rendered CT (3DVR-CT), and a 3DVR-CT movie, were performed on 30 patients who underwent laparoscopic donor nephrectomy (10 right side, 20 left side) for predicting the location of the renal arteries and renal, adrenal, gonadal, and lumbar veins. These findings were compared with videos obtained during the operation. Two of 37 renal arteries observed intraoperatively were missed by standard axial CT and 3DVR-CT, whereas all arteries were identified by the 3DVR-CT movie. Two of 36 renal veins were missed by standard axial CT and 3DVR-CT, whereas 1 was missed by the 3DVR-CT movie. In 20 left renal hilar anatomical structures, 20 adrenal, 20 gonadal, and 22 lumbar veins were observed during the operation. Preoperatively, the standard axial CT, 3DVR-CT, and 3DVR-CT movie detected 11, 19, and 20 adrenal veins; 13, 14, and 19 gonadal veins; and 6, 11, and 15 lumbar veins, respectively. Overall, of 135 renal vascular structures, the standard axial CT, 3DVR-CT, and 3DVR-CT movie accurately detected 99 (73.3%), 113 (83.7%), and 126 (93.3%) vessels, respectively, which indicated that the 3DVR-CT movie demonstrated a significantly higher detection rate than other CT-based imaging methods (P renal vascular anatomy before laparoscopic donor nephrectomy.

  4. Axial to transverse energy mixing dynamics in octupole-based magnetostatic antihydrogen traps

    Science.gov (United States)

    Zhong, M.; Fajans, J.; Zukor, A. F.

    2018-05-01

    The nature of the trajectories of antihydrogen atoms confined in an octupole minimum-B trap is of great importance for upcoming spectroscopy, cooling, and gravity experiments. Of particular interest is the mixing time between the axial and transverse energies for the antiatoms. Here, using computer simulations, we establish that almost all trajectories are chaotic, and then quantify the characteristic mixing time between the axial and transverse energies. We find that there are two classes of trajectories: for trajectories whose axial energy is higher than about 20% of the total energy, the axial energy substantially mixes within about 10 s, whereas for trajectories whose axial energy is lower than about 10% of the total energy, the axial energy remains nearly constant for 1000 s or longer.

  5. A Guide to Axial-Flow Turbine Off-Design Computer Program AXOD2

    Science.gov (United States)

    Chen, Shu-Cheng S.

    2014-01-01

    A Users Guide for the axial flow turbine off-design computer program AXOD2 is composed in this paper. This Users Guide is supplementary to the original Users Manual of AXOD. Three notable contributions of AXOD2 to its predecessor AXOD, both in the context of the Guide or in the functionality of the code, are described and discussed in length. These are: 1) a rational representation of the mathematical principles applied, with concise descriptions of the formulas implemented in the actual coding. Their physical implications are addressed; 2) the creation and documentation of an Addendum Listing of input namelist-parameters unique to AXOD2, that differ from or are in addition to the original input-namelists given in the Manual of AXOD. Their usages are discussed; and 3) the institution of proper stoppages of the code execution, encoding termination messaging and error messages of the execution to AXOD2. These measures are to safe-guard the integrity of the code execution, such that a failure mode encountered during a case-study would not plunge the code execution into indefinite loop, or cause a blow-out of the program execution. Details on these are discussed and illustrated in this paper. Moreover, this computer program has since been reconstructed substantially. Standard FORTRAN Langue was instituted, and the code was formatted in Double Precision (REAL*8). As the result, the code is now suited for use in a local Desktop Computer Environment, is perfectly portable to any Operating System, and can be executed by any FORTRAN compiler equivalent to a FORTRAN 9095 compiler. AXOD2 will be available through NASA Glenn Research Center (GRC) Software Repository.

  6. Evaluation of efficiency of axial profiling in WWER-440 fuel assemblies

    International Nuclear Information System (INIS)

    Ananjev, Yu. A.; Kurakin, K. Yu.; Artemov, V.G.; Ivanov, A.S.

    2005-01-01

    The present report deals with consideration of fuel enrichment axial profiling in WWER-440 assemblies. The study is performed on improving the effectiveness of fuel utilization using the example of implementing the axial profiling in the assemblies of the second generation. For simulation of fuel loadings the computer code package SAPFIR 9 5 and RC is used that allows for correct consideration of specific features of assemblies design changes. The methodical approach to assessment of effectiveness of implementing the axial profiling is considered with the use of capabilities of the mentioned code package. In conclusion the recommendations are given on using the fuel enrichment axial profiling in WWER-440 assemblies (Authors)

  7. Acute gallbladder torsion - a continued pre-operative diagnostic dilemma

    Directory of Open Access Journals (Sweden)

    Desrochers Randal

    2011-04-01

    Full Text Available Abstract Acute gallbladder volvulus continues to remain a relatively uncommon process, manifesting itself usually during exploration for an acute surgical abdomen with a presumptive diagnosis of acute cholecystitis. The pathophysiology is that of mechanical organo-axial torsion along the gallbladder's longitudinal axis involving the cystic duct and cystic artery, and with a pre-requisite of local mesenteric redundancy. The demographic tendency is septua- and octo-genarians of the female sex, and its overall incidence is increasing, this being attributed to increasing life expectancy. We discuss two cases of elderly, fragile women presenting to the emergency department complaining of sudden onset right upper quadrant abdominal pain. Their subsequent evaluation suggested acute cholecystitis. Ultimately both were taken to the operating room where the correct diagnosis of gallbladder torsion was made. Pre-operative diagnosis continues to be a major challenge with only 4 cases reported in the literature diagnosed with pre-operative imaging; the remainder were found intra-operatively. Consequently, a delay in diagnosis can have devastating patient outcomes. Herein we propose a necessary high index of suspicion for gallbladder volvulus in the outlined patient demographic with symptoms and signs mimicking acute cholecystitis.

  8. Axial computed tomography evaluation of the internal nasal valve correlates with clinical valve narrowing and patient complaint.

    Science.gov (United States)

    Moche, Jason A; Cohen, Justin C; Pearlman, Steven J

    2013-07-01

    The objective of this work was to explore the utility of axial computed tomography (CT) imaging to objectively define a narrow internal nasal valve, and compare those findings with clinical examination and patient complaint. Retrospective review from a single facial plastic surgery center. We reviewed 40 consecutive patients evaluated for either sinusitis or nasal airway obstruction for which a CT scan was obtained at a single radiology institution. Thirty-six complete office records were examined for the presence of clinical internal valve narrowing and complaints of nasal obstruction. In total, 72 internal nasal valves were analyzed using axial plane CT and measurements were compared to clinical findings and presence of airway obstruction. Measured valve areas for clinically normal internal nasal valves averaged 0.47 cm(2) vs 0.28 cm(2) for clinically narrow valves, a decrease of 40.4%. In unobstructed nasal airways the valve area averaged 0.51 cm(2) vs 0.38 cm(2) in obstructed airways, a difference of 25.5%. A radiographically measured valve area of <0.30 cm(2) suggests clinical narrowing with a sensitivity of 71.4%, specificity of 88.9%, positive predictive value of 62.5%, and negative predictive value of 92.3%. Using standard axial CT imaging we describe an objective method of radiographically evaluating the nasal valve, demonstrating strong correlation with physical examination and patient complaint. Additionally, radiographic valve areas can be used to screen for clinically narrow nasal valves with good sensitivity and specificity, providing a novel straightforward method for nasal valve assessment. © 2012 ARS-AAOA, LLC.

  9. New concepts in preoperative imaging of anorectal malformation. New concepts in imaging of ARM

    Energy Technology Data Exchange (ETDEWEB)

    Taccone, A.; Delliacqua, A.; Marzoli, A. (Children' s Hospital G. Gaslini, Genoa (Italy). Dept. of Radiology); Martucciello, G.; Jasonni, V. (Children' s Hospital G. Gaslini, Genoa (Italy). Dept. of Pediatric Surgery); Dodero, P. (Children' s Hospital G. Gaslini, Genoa (Italy). Dept. of Intensive Care Unit); Salomone, G. (Children' s Hospital G. Gaslini, Genoa (Italy). Surgical Emergency Unit)

    1992-06-01

    In this study of 14 patients with anorectal anomalies CT and MRI were employed for preoperative assessment. The use of a pressure enhanced water soluble enema via the colostomy proved to be an extremely efficient method for showing a fistula. MRI studies were enhanced by the use of vaseline oil and in one case this technique was used prior to surgery to provide important information by injecting through a perineal fistula. CT and axial MRI proved to be more valuable than sagittal MRI which is only useful for the length of the atretic segment. The authors consider that a combined approach using pressure enhanced water soluble enema and MRI will provide the most valuable preoperative information to plan a successful operative approach and enable an accurate prognostic evaluation of continence in these difficult and complex patients. (orig.).

  10. Role of computed tomography in the integral diagnostic process of paranasal cavities tumors

    International Nuclear Information System (INIS)

    Lazarova, I.

    1990-01-01

    Results are reported of computed tomographic examination of 129 patients from 3 to 74 years of age, on clinical grounds suspected of having, or histologically verified, tumors of the paranasal cavities. Axial and/or coronary scanning (depending on the case) was performed on computed tomograph Tomoscan-310, according to previously selected programs. Computed tomography was evaluated with regard to the possibility for diagnosing tumors of the paranasal sinuses and its role in furnishing additional information in these diseases. The clearcut differentiation on the computed tomograms both of the bone structures and of the soft tissue - muscles, vessels, connective tissue and fatty tissue spaces - is emphasized. The clinical significance of this special X-ray method of examination in the preoperative period by demonstrating the different directions in which the tumors spread and the possibility for adequate planning of the radiotherapeutic field and posttherapeutic follow-up the pathologic process are pointed out. 5 figs., 5 refs

  11. Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Kyung Hoon; Jeong, Ho Gul; Park, Hyok; Park, Chang Seo; Kim, Kee Deog [Department of Oral and Maxillofacial Radiology, Oral Science Research Center, College of Dentistry, Yonsei University, Seoul (Korea, Republic of)

    2009-03-15

    The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Five partially edentulous dry human mandibles, with 1 X 1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographs were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0 (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  12. Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area

    International Nuclear Information System (INIS)

    Sun, Kyung Hoon; Jeong, Ho Gul; Park, Hyok; Park, Chang Seo; Kim, Kee Deog

    2009-01-01

    The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Five partially edentulous dry human mandibles, with 1 X 1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographs were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0 (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  13. Preoperative CT analysis of the mandible and maxilla for permanent dental prosthetic implantation

    International Nuclear Information System (INIS)

    Rothman, S.L.G.; Rhodes, M.L.; Schwarz, M.; Chafetz, N.I.

    1987-01-01

    The Branemark technique for permanently implanting dental prostheses is becoming universally accepted. The surgeon requires detailed knowledge of the cross-sectional anatomy of the alveolar ridges and inferior alveolar nerve for safe placement of the titanium fixtures. Axial CT scans of the mandible and maxilla, with oblique and panoramic CT reformations, were obtained in more than 100 patients. This report describes the anatomic variations in the maxilla and mandible as they relate to dental implantation surgery. The authors demonstrate the utility of this technique in preoperative surgical planning and postoperative evaluation

  14. Preoperative computed tomography for determining nodal status combined with histologic grading as a prognostic factor for patients with tongue carcinoma

    International Nuclear Information System (INIS)

    Ogura, Ichiro; Kurabayashi, Tohru; Amagasa, Teruo; Iwaki, Hiroshi; Sasaki, Takehito

    2001-01-01

    The purpose of this study was to evaluate the predictive value of preoperative neck computed tomography (CT) in combination with histologic grading as a prognostic factor for patients with tongue carcinoma. Fifty-five patients with squamous cell carcinoma of the tongue were examined by CT prior to radical neck dissection. The locoregional failure and survival rates of these patients were analyzed in relation to their clinical characteristics, histologic grading (World Health Organization, WHO) based on tongue biopsy, and imaging diagnoses prior to surgery. Logistic multivariate regression analysis showed that both histologic grading and number of metastatic lymph nodes on CT were significant and independent prognostic factors in locoregional failure (p=0.009 and p=0.009, respectively). When the numebr of metastatic lymph nodes detected on preoperative neck CT were combined with the histologic grading for the evaluation, the five-year overall survival rates of A group (0 node with any Grade, or 1 node with Grade I-II) and B group (1 node with Grade III, or 2 or more nodes with any Grade) were 74.5% and 37.5%, respectively (p=0.001). The difference was more significant than histologic grading alone or the number of metastatic lymph nodes seen on CT alone. The combination of preoperative neck CT with histologic grading of the primary tumor is useful as a prognostic indicator for patients with tongue carcinoma. (author)

  15. Assessing the attractive/repulsive force balance in axial cyclohexane C-Hax ···Yax contacts: A combined computational analysis in monosubstituted cyclohexanes.

    Science.gov (United States)

    Silva Lopez, Carlos; Nieto Faza, Olalla; De Proft, Frank; Kolocouris, Antonios

    2016-11-15

    The interactions of axial substituents in monosubstituted cyclohexane rings are studied in this work using an array of different computational techniques. Additionally, the anomalous axial preference for some bulky substituents is related to stabilizing dispersion interactions. We find that the C-H ax ···Y ax contacts for various substituents with distances ranging from 2 to ∼5 Å may include attractive dispersion forces that can affect the conformational equilibrium; these forces co-exist with Pauli repulsive forces effected by Y ax group due to van der Waals sphere penetration. At distances between 2 and 3 Å stabilizing electron transfer interactions were calculated and the combination of natural bond orbital and QTAIM analysis showed that, in certain cases, Y ax  =  t Bu, C ax -O or C ax  = O or S ax  = O or C ax  = S this interaction can be characterized as an improper H-bond. DFT-D3 and non-covalent interactions calculations (NCIs) in cyclohexane derivatives with Y ax  = SiOR 3 including H Yax ···H cy surfaces at distances ranging between 4 and 6 Å suggest that dispersion has a clear effect on the experimentally observed stabilization of the axial conformer. NCIs computed from the reduced density gradient help to visually identify and analyze these interactions. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  16. Evaluation of Optic Canal and Surrounding Structures Using Cone Beam Computed Tomography: Considerations for Maxillofacial Surgery.

    Science.gov (United States)

    Sinanoglu, Alper; Orhan, Kaan; Kursun, Sebnem; Inceoglu, Beste; Oztas, Bengi

    2016-07-01

    The optic canal connects the anterior cranial fossa and the orbit and maintains the optic nerve and the ophthalmic artery. Within the extent of the surgical approach of the region, risk of iatrogenic injury of the neural and vascular structures increases. The aim of this retrospective morphometric study is to investigate the radiological anatomy of orbita, optic canal, and its surrounding using cone beam computed tomography (CBCT) scans in a group of Turkish population.Cone beam computed tomography images of a total of 182 patients were evaluated by 2 observers. Anatomical parameters regarding optic canal and orbita were measured for all patients from axial, sagittal, and three-dimensional reconstructed images. To assess intraobserver reliability, the Wilcoxon matched-pairs test was used. Pearson χ test and Student t test were performed for statistical analysis of differences, sex, localization, and measurements (P  0.05). The orbita width and height were larger for the males than females (P  0.05). Examination CBCT scans revealed that the shape of the optic canal was 70% funnel and 28% Hourglass shape, 2% amorph type round.These results provide detailed knowledge of the anatomical characteristics in the orbital area which may be of assistance for surgeons preoperatively. Cone beam computed tomography scans can be an alternative modality for multislice computed tomography with submillimeter resolution and lower dose in preoperative imaging of the orbit.

  17. Axial torsion of meckel's diverticulum causing small bowel obstruction in adult: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Youn, In Kyung; Lee, Su Lim; Ku, Young Mi [Dept. of Radiology, Uijeongbu St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu (Korea, Republic of)

    2016-02-15

    Meckel's diverticulum (MD) is the most common congenital abnormality of the gastrointestinal tract that is prevalent in 2–3% of the population. The lifetime risk of complications is estimated at 4%. Small bowel obstruction is the second most common complication of MD. Among the causes of bowel obstruction, axial torsion of MD is the rarest complication. Urgent surgical treatment is needed in cases of small bowel obstruction associated with torsion of MD. Pre-operative diagnosis of MD as a cause of small bowel obstruction is difficult, because the diagnosis can be made only if the diverticulum is delineated at the site of obstruction. We reported a case of axial torsion of MD with necrosis that caused proximal small bowel perforation in a 21 year old male.

  18. Preoperative 3D FSE T1-Weighted MR Plaque Imaging for Severely Stenotic Cervical ICA: Accuracy of Predicting Emboli during Carotid Endarterectomy

    Directory of Open Access Journals (Sweden)

    Yasushi Ogasawara

    2016-10-01

    Full Text Available The aim of the present study was to determine whether preoperative three-dimensional (3D fast spin-echo (FSE T1-weighted magnetic resonance (MR plaque imaging for severely stenotic cervical carotid arteries could accurately predict the development of artery-to-artery emboli during exposure of the carotid arteries in carotid endarterectomy (CEA. Seventy-five patients underwent preoperative MR plaque imaging and CEA under transcranial Doppler ultrasonography of the ipsilateral middle cerebral artery. On reformatted axial MR image slices showing the maximum plaque occupation rate (POR and maximum plaque intensity for each patient, the contrast ratio (CR was calculated by dividing the internal carotid artery plaque signal intensity by the sternocleidomastoid muscle signal intensity. For all patients, the area under the receiver operating characteristic curve (AUC—used to discriminate between the presence and absence of microembolic signals—was significantly greater for the CR on the axial image with maximum plaque intensity (CRmax intensity (0.941 than for that with the maximum POR (0.885 (p < 0.05. For 32 patients in whom both the maximum POR and the maximum plaque density were identified, the AUCs for the CR were 1.000. Preoperative 3D FSE T1-weighted MR plaque imaging accurately predicts the development of artery-to-artery emboli during exposure of the carotid arteries in CEA.

  19. Using axial magnetized permanent rings to build axial gradient magnetic field

    International Nuclear Information System (INIS)

    Peng Quanling

    2003-01-01

    Axial field produced by an axially magnetized permanent ring was studied. For two permanent magnet rings, if they are magnetized in the same direction, a nearly uniform axial field can be produced; if they are magnetized in opposite direction, an axial gradient field can be produced in the region between the two permanent rings, with the field strength changing from -B 0 to B 0 . A high gradient axial magnetic field has been built by using two axially magnetized permanent rings, the measured field results agree with the PANDIRA calculation very well. It is desirable that the field gradient can be varied to match various requirements. A method to produce the variable gradient field is presented. Axial gradient field can also be used as a beam focusing facility for linear accelerator if axial periodic field can be produced. Its magnetic field is similar to that of a solenoid, in which, large stray field will leak to the outside environment. A method for shielding the outside stray field is discussed

  20. Axially modulated arch resonator for logic and memory applications

    KAUST Repository

    Hafiz, Md Abdullah Al

    2018-01-17

    We demonstrate reconfigurable logic and random access memory devices based on an axially modulated clamped-guided arch resonator. The device is electrostatically actuated and the motional signal is capacitively sensed, while the resonance frequency is modulated through an axial electrostatic force from the guided side of the microbeam. A multi-physics finite element model is used to verify the effectiveness of the axial modulation. We present two case studies: first, a reconfigurable two-input logic gate based on the linear resonance frequency modulation, and second, a memory element based on the hysteretic frequency response of the resonator working in the nonlinear regime. The energy consumptions of the device for both logic and memory operations are in the range of picojoules, promising for energy efficient alternative computing paradigm.

  1. Axial power monitoring uncertainty in the Savannah River Reactors

    International Nuclear Information System (INIS)

    Losey, D.C.; Revolinski, S.M.

    1990-01-01

    The results of this analysis quantified the uncertainty associated with monitoring the Axial Power Shape (APS) in the Savannah River Reactors. Thermocouples at each assembly flow exit map the radial power distribution and are the primary means of monitoring power in these reactors. The remaining uncertainty in power monitoring is associated with the relative axial power distribution. The APS is monitored by seven sensors that respond to power on each of nine vertical Axial Power Monitor (APM) rods. Computation of the APS uncertainty, for the reactor power limits analysis, started with a large database of APM rod measurements spanning several years of reactor operation. A computer algorithm was used to randomly select a sample of APSs which were input to a code. This code modeled the thermal-hydraulic performance of a single fuel assembly during a design basis Loss-of Coolant Accident. The assembly power limit at Onset of Significant Voiding was computed for each APS. The output was a distribution of expected assembly power limits that was adjusted to account for the biases caused by instrumentation error and by measuring 7 points rather than a continuous APS. Statistical analysis of the final assembly power limit distribution showed that reducing reactor power by approximately 3% was sufficient to account for APS variation. This data confirmed expectations that the assembly exit thermocouples provide all information needed for monitoring core power. The computational analysis results also quantified the contribution to power limits of the various uncertainties such as instrumentation error

  2. A critical inventory of preoperative skull replicas.

    Science.gov (United States)

    Fasel, J H D; Beinemann, J; Schaller, K; Gailloud, P

    2013-09-01

    Physical replicas of organs are used increasingly for preoperative planning. The quality of these models is generally accepted by surgeons. In view of the strong trend towards minimally invasive and personalised surgery, however, the aim of this investigation was to assess qualitatively the accuracy of such replicas, using skull models as an example. Skull imaging was acquired for three cadavers by computed tomography using clinical routine parameters. After digital three-dimensional (3D) reconstruction, physical replicas were produced by 3D printing. The facsimilia were analysed systematically and compared with the best gold standard possible: the macerated skull itself. The skull models were far from anatomically accurate. Non-conforming rendering was observed in particular for foramina, sutures, notches, fissures, grooves, channels, tuberosities, thin-walled structures, sharp peaks and crests, and teeth. Surgeons should be aware that preoperative models may not yet render the exact anatomy of the patient under consideration and are advised to continue relying, in specific conditions, on their own analysis of the native computed tomography or magnetic resonance imaging.

  3. The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas; CT und MRT des erworbenen Cholesteatoms: Prae- und postoperative Bildgebung

    Energy Technology Data Exchange (ETDEWEB)

    Krestan, C.; Czerny, C. [Abteilung fuer Osteologie, Univ.-Klinik fuer Radiodiagnostik, Wien (Austria); Gstoettner, W. [Univ.-Klinik fuer Hals-Nasen-Ohren-Heilkunde, Frankfurt (Germany); Franz, P. [Univ.-Klinik fuer Hals-Nasen-Ohren-Heilkunde, Wien (Austria)

    2003-03-01

    The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. Postoperative HRCT depicted bony erosions caused by recurrent cholesteatoma, bony defects of the facial nerve and of the labyrinth, and a defect of the tegmen tympani with a soft tissue mass in the middle ear. Postoperative MRI delineated neuritis of the facial nerve, labyrinthitis, and a meningo-encephalocele protruding into the middle ear. HRCT and MRI are excellent imaging tools to depict either bony or soft tissue complications or both if caused by acquired cholesteatomas. According to our findings and to the literature HRCT and MRI are complementary imaging methods to depict pre- or postoperative complications of acquired cholesteatomas if these are suspected by clinical examination. (orig.) [German] In dieser Arbeit wird die Rolle der hochaufloesenden Computertomographie (HRCT) und der Magnetresonanztomographie (MRT) zur Abklaerung prae- und postoperativ bedingter Komplikationen erworbener Cholesteatome beschrieben. Die Bildgebung wurde sowohl mit der HRCT als auch mit der MRT durchgefuehrt. Die HRCT und die MRT wurden in axialer und koronaler Ebene (auch

  4. Modular preoperative planning software for computer-aided oral implantology and the application of a novel stereolithographic template: a pilot study.

    Science.gov (United States)

    Chen, Xiaojun; Yuan, Jianbing; Wang, Chengtao; Huang, Yuanliang; Kang, Lu

    2010-09-01

    In the field of oral implantology, there is a trend toward computer-aided implant surgery, especially the application of computerized tomography (CT)-derived surgical templates. However, because of relatively unsatisfactory match between the templates and receptor sites, conventional surgical templates may not be accurate enough for the severely resorbed edentulous cases during the procedure of transferring the preoperative plan to the actual surgery. The purpose of this study is to introduce a novel bone-tooth-combined-supported surgical guide, which is designed by utilizing a special modular software and fabricated via stereolithography technique using both laser scanning and CT imaging, thus improving the fit accuracy and reliability. A modular preoperative planning software was developed for computer-aided oral implantology. With the introduction of dynamic link libraries and some well-known free, open-source software libraries such as Visualization Toolkit (Kitware, Inc., New York, USA) and Insight Toolkit (Kitware, Inc.) a plug-in evolutive software architecture was established, allowing for expandability, accessibility, and maintainability in our system. To provide a link between the preoperative plan and the actual surgery, a novel bone-tooth-combined-supported surgical template was fabricated, utilizing laser scanning, image registration, and rapid prototyping. Clinical studies were conducted on four partially edentulous cases to make a comparison with the conventional bone-supported templates. The fixation was more stable than tooth-supported templates because laser scanning technology obtained detailed dentition information, which brought about the unique topography between the match surface of the templates and the adjacent teeth. The average distance deviations at the coronal and apical point of the implant were 0.66 mm (range: 0.3-1.2) and 0.86 mm (range: 0.4-1.2), and the average angle deviation was 1.84 degrees (range: 0.6-2.8 degrees ). This pilot

  5. Optimization of residual heat removal pump axial thrust and axial bearing

    International Nuclear Information System (INIS)

    Schubert, F.

    1996-01-01

    The residual heat removal (RHR) pumps of German 1300 megawatt pressurized-water reactor (PWR) power plants are of the single stage end suction type with volute casing or with diffuser and forged circular casing. Due to the service conditions the pumps have to cover the full capacity range as well as a big variation in suction static pressure. This results in a big difference in the axial thrust that has to be borne by the axial bearing. Because these pumps are designed to operate without auxiliary systems (things that do not exist can not fail), they are equipped with antifriction bearings and sump oil lubrication. To minimize the heat production within the bearing casing, a number of PWR plants have pumps with combined axial/radial bearings of the ball type. Due to the fact that the maximum axial thrust caused by static pressure and hydrodynamic forces on the impeller is too big to be borne by that type of axial bearing, the impellers were designed to produce a hydrodynamic axial force that counteracts the static axial force. Thus, the resulting axial thrust may change direction when the static pressure varies

  6. Optimization of residual heat removal pump axial thrust and axial bearing

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, F.

    1996-12-01

    The residual heat removal (RHR) pumps of German 1300 megawatt pressurized-water reactor (PWR) power plants are of the single stage end suction type with volute casing or with diffuser and forged circular casing. Due to the service conditions the pumps have to cover the full capacity range as well as a big variation in suction static pressure. This results in a big difference in the axial thrust that has to be borne by the axial bearing. Because these pumps are designed to operate without auxiliary systems (things that do not exist can not fail), they are equipped with antifriction bearings and sump oil lubrication. To minimize the heat production within the bearing casing, a number of PWR plants have pumps with combined axial/radial bearings of the ball type. Due to the fact that the maximum axial thrust caused by static pressure and hydrodynamic forces on the impeller is too big to be borne by that type of axial bearing, the impellers were designed to produce a hydrodynamic axial force that counteracts the static axial force. Thus, the resulting axial thrust may change direction when the static pressure varies.

  7. Diagnostic efficacy of the preoperative lymphoscintigraphy, Ga-67 scintigraphy and computed tomography for detection of lymph node metastasis in cases with ovarian or endometrial carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Ozalp, S.; Yalcin, O.T.; Polay, S. [Osmangazi Univ. School of Medicine, Dept. of Obstetrics and Gynecology, Eskisehir (Turkey); Aslan, N.; Vardareli, E. [Osmangazi Univ. School of Medicine, Dept. of Nuclear Medicine, Eskisehir (Turkey); Adapinar, B. [Osmangazi Univ. School of Medicine, Dept. of Radiology, Eskisehir (Turkey)

    1999-02-01

    Background: To investigate the diagnostic efficacy of preoperative lymphoscintigraphy (LS), Ga-67 scintigraphy (GS) and computed tomography (CT) for detection of lymph node metastasis in patients with endometrial or ovarian carcinoma. Methods: The results of preoperative LS, GS and CT used to detect lymph node metastasis were compared to the postoperative histopathological results of lymph node dissection materials of a total of 37 patients, including 16 patients with endometrial and 21 patients with ovarian carcinomas. The diagnostic efficacy of these methods for detecting lymph node metastasis were calculated. Results: When the results of all of the patients were taken into account, the preoperative LS, GS and CT were found to have sensitivities of 50%, 20% and 40% and specificities of 51.8%, 96.3%, and 92.6%, respectively, for detection of pelvic lymph node metastasis. The same methods had sensitivities of 27.3%, 27.3% and 72.7% and specificities of 88.5%, 88.5%, 84.6%, respectively, for detecting para-aortic lymph node metastasis in all patients. Conclusion: These data suggested that although LS, GS and CT had relatively high specificity, low sensitivity of these imaging methods precluded their routine preoperative use for diagnosis of lymph node metastasis of ovarian or endometrial carcinoma. (au) 22 refs.

  8. Numerical investigation on vibration and noise induced by unsteady flow in an axial-flow pump

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Eryun; Ma, Zui Ling; Yang, Ai Ling; Nan, Guo Fang [School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai (China); Zhao, Gai Ping [School of Medical Instruments and Food Engineering, University of Shanghai for Science and Technology, Shanghai (China); Li, Guo Ping [Shanghai Marine Equipment Research Institute, Shanghai (China)

    2016-12-15

    Full-scale structural vibration and noise induced by flow in an axial-flow pump was simulated by a hybrid numerical method. An unsteady flow field was solved by a large eddy simulation-based computational fluid dynamics commercial code, Fluent. An experimental validation on pressure fluctuations was performed to impose an appropriate vibration exciting source. The consistency between the computed results and experimental tests were interesting. The modes of the axial-flow pump were computed by the finite element method. After that, the pump vibration and sound field were solved using a coupled vibro-acoustic model. The numerical results indicated that the the blade-passing frequency was the dominant frequency of the vibration acceleration of the pump. This result was consistent with frequency spectral characteristics of unsteady pressure fluctuation. Finally, comparisons of the vibration acceleration between the computed results and the experimental test were conducted. These comparisons validated the computed results. This study shows that using the hybrid numerical method to evaluate the flow-induced vibration and noise generated in an axial-flow pump is feasible.

  9. Anatomic variants of interest in endoscopic sinus surgery: role of computed tomography

    International Nuclear Information System (INIS)

    Alonso, S.; Arenas, J.; Fernandez, F.; Gil, S.; Guirau, M. D.

    2000-01-01

    The detailed radiological study of the anatomy of the nasal cavities and paranasal sinus is essential prior to endoscopic sinus surgery since, on the one hand, it discloses the extent of the disease and, on the other hand, it aids in the detection of the numerous anatomic variants, some of which are of great interest to the endoscopic as the lack of preoperative knowledge of them may increase the risk of complications. the objective of the present report is to review these variants, stressing those that may be associated with a greater surgical risk. Although coronal computed tomography is the technique of choice for pre endoscopy examination, certain structures and anatomic variants are better viewed in axial images. These exceptions include anterior and posterior walls of the frontal sinuses, the anatomic relationships between posterior ethmoid complex and the sphenoid sinus, the relationships between the sphenoid sinus and the optic nerve, and the detection of Onodi cells. Thus, we recommend that the radiological examination include both coronal and axial images. (Author) 16 refs

  10. Computed tomography for preoperative planning in minimal-invasive total hip arthroplasty: Radiation exposure and cost analysis

    Energy Technology Data Exchange (ETDEWEB)

    Huppertz, Alexander, E-mail: Alexander.Huppertz@charite.de [Imaging Science Institute Charite Berlin, Robert-Koch-Platz 7, D-10115 Berlin (Germany); Department of Radiology, Medical Physics, Charite-University Hospitals of Berlin, Chariteplatz 1, D-10117 Berlin (Germany); Radmer, Sebastian, E-mail: s.radmer@immanuel.de [Department of Orthopedic Surgery and Rheumatology, Immanuel-Krankenhaus, Koenigstr. 63, D-14109, Berlin (Germany); Asbach, Patrick, E-mail: Patrick.Asbach@charite.de [Department of Radiology, Medical Physics, Charite-University Hospitals of Berlin, Chariteplatz 1, D-10117 Berlin (Germany); Juran, Ralf, E-mail: ralf.juran@charite.de [Department of Radiology, Medical Physics, Charite-University Hospitals of Berlin, Chariteplatz 1, D-10117 Berlin (Germany); Schwenke, Carsten, E-mail: carsten.schwenke@scossis.de [Biostatistician, Scossis Statistical Consulting, Zeltinger Str. 58G, D-13465 Berlin (Germany); Diederichs, Gerd, E-mail: gerd.diederichs@charite.de [Department of Radiology, Medical Physics, Charite-University Hospitals of Berlin, Chariteplatz 1, D-10117 Berlin (Germany); Hamm, Bernd, E-mail: Bernd.Hamm@charite.de [Department of Radiology, Medical Physics, Charite-University Hospitals of Berlin, Chariteplatz 1, D-10117 Berlin (Germany); Sparmann, Martin, E-mail: m.sparmann@immanuel.de [Department of Orthopedic Surgery and Rheumatology, Immanuel-Krankenhaus, Koenigstr. 63, D-14109, Berlin (Germany)

    2011-06-15

    Computed tomography (CT) was used for preoperative planning of minimal-invasive total hip arthroplasty (THA). 92 patients (50 males, 42 females, mean age 59.5 years) with a mean body-mass-index (BMI) of 26.5 kg/m{sup 2} underwent 64-slice CT to depict the pelvis, the knee and the ankle in three independent acquisitions using combined x-, y-, and z-axis tube current modulation. Arthroplasty planning was performed using 3D-Hip Plan (Symbios, Switzerland) and patient radiation dose exposure was determined. The effects of BMI, gender, and contralateral THA on the effective dose were evaluated by an analysis-of-variance. A process-cost-analysis from the hospital perspective was done. All CT examinations were of sufficient image quality for 3D-THA planning. A mean effective dose of 4.0 mSv (SD 0.9 mSv) modeled by the BMI (p < 0.0001) was calculated. The presence of a contralateral THA (9/92 patients; p = 0.15) and the difference between males and females were not significant (p = 0.08). Personnel involved were the radiologist (4 min), the surgeon (16 min), the radiographer (12 min), and administrative personnel (4 min). A CT operation time of 11 min and direct per-patient costs of 52.80 Euro were recorded. Preoperative CT for THA was associated with a slight and justifiable increase of radiation exposure in comparison to conventional radiographs and low per-patient costs.

  11. The geometrical theory of diffraction for axially symmetric reflectors

    DEFF Research Database (Denmark)

    Rusch, W.; Sørensen, O.

    1975-01-01

    The geometrical theory of diffraction (GTD) (cf. [1], for example) may be applied advantageously to many axially symmetric reflector antenna geometries. The material in this communication presents analytical, computational, and experimental results for commonly encountered reflector geometries...

  12. BWR AXIAL PROFILE

    International Nuclear Information System (INIS)

    Huffer, J.

    2004-01-01

    The purpose of this calculation is to develop axial profiles for estimating the axial variation in burnup of a boiling water reactor (BWR) assembly spent nuclear fuel (SNF) given the average burnup of an assembly. A discharged fuel assembly typically exhibits higher burnup in the center and lower burnup at the ends of the assembly. Criticality safety analyses taking credit for SNF burnup must account for axially varying burnup relative to calculations based on uniformly distributed assembly average burnup due to the under-burned tips. Thus, accounting for axially varying burnup in criticality analyses is also referred to as accounting for the ''end effect'' reactivity. The magnitude of the reactivity change due to ''end effect'' is dependent on the initial assembly enrichment, the assembly average burnup, and the particular axial profile characterizing the burnup distribution. The set of bounding axial profiles should incorporate multiple BWR core designs and provide statistical confidence (95 percent confidence that 95 percent of the population is bound by the profile) that end nodes are conservatively represented. The profiles should also conserve the overall burnup of the fuel assembly. More background on BWR axial profiles is provided in Attachment I

  13. The value of multislice spiral CT in the pre-operative diagnosis of cleft palate

    International Nuclear Information System (INIS)

    Tang Guangxi; Sun Lianfen; Zhang Xiaolin; Yu Chengxin; Lu Ji; Wang Xiaopeng; Li Liya; Yang Cheng; Wang Jun; Tian Yiqing

    2004-01-01

    Objective: To evaluate the practical value of multislice spiral CT (MSCT) in the preoperative diagnosis of cleft palate. Methods: Twenty patients with cleft palate were examined by using thin-slice (1.25 mm/4i) axial MSCT scanning and CT virtual endoscope (CTVE) imaging before and after operations. The cleft of each lesion was measured in the primary axial images. Results: Of the 20 cases, soft-and-hard cleft palate (grade II) was detected in 10 cases, with the clefts of soft palate between 1.5 cm and 2.2 cm, and the clefts of soft-and-hard palate between 1.2 cm and 2.0 cm. The right utter cleft palates were found in 3 cases with the clefts of soft palate between 2.0 cm and 2.5 cm, the clefts of soft-and-hard palate between 2.0 cm and 2.4 cm, and the clefts of hard palate between 1.8 cm and 2.2 cm. The left utter cleft palates (grade III) were found in 5 cases with the clefts of soft palate between 1.2 cm and 1.8 cm, the clefts of soft-and-hard palate between 0.9 cm and 2.0 cm, and the clefts of hard palate between 0.9 cm and 1.8 cm. The bilateral utter cleft palates (grade III) were detected in 2 cases with the clefts of soft palate between 2.1 cm and 2.3 cm, the clefts of soft-and-hard palate between 1.8 cm and 2.0 cm, and the clefts of hard palate between 1.9 cm and 2.3 cm. Conclusion: MSCT could excellently display the shape of all lesions before operation, especially the splitting degree of hard cleft palates in the axial images. Accurate measurements could be done for the cleft of different lesions in MSCT images. CTVE could clearly and directly show the shape of the lesion's interior surface. The pre-operative and post-operative images of each case could be perfectly compared by the combination of MSCT and CTVE

  14. Comparison of Oral Contrast-Enhanced Transabdominal Ultrasound Imaging With Transverse Contrast-Enhanced Computed Tomography in Preoperative Tumor Staging of Advanced Gastric Carcinoma.

    Science.gov (United States)

    He, Xuemei; Sun, Jing; Huang, Xiaoling; Zeng, Chun; Ge, Yinggang; Zhang, Jun; Wu, Jingxian

    2017-12-01

    This study assessed the diagnostic performance of transabdominal oral contrast-enhanced ultrasound (US) imaging for preoperative tumor staging of advanced gastric carcinoma by comparing it with transverse contrast-enhanced computed tomography (CT). This retrospective study included 42 patients with advanced gastric cancer who underwent laparoscopy, radical surgery, or palliative surgery because of serious complications and had a body mass index of less than 25 kg/m 2 . A cereal-based oral contrast agent was used for transabdominal oral contrast-enhanced US. Retrospective analyses were conducted using preoperative tumor staging data acquired by either transabdominal oral contrast-enhanced US or transverse contrast-enhanced CT. Both contrast-enhanced US and contrast-enhanced CT examinations were reviewed by 2 experienced radiologists independently for preoperative tumor staging according to the seventh edition of the TNM classification. The accuracy, sensitivity, and specificity were calculated by comparing the results of contrast-enhanced US and contrast-enhanced CT with pathologic findings. The overall accuracies of the imaging modalities were compared by the McNemar test. No significant difference was noted in the overall accuracy of transabdominal oral contrast-enhanced US (86% [36 of 42]) and transverse contrast-enhanced CT (83% [35 of 42] P > .999). For stage T2 to T4 gastric cancer, the accuracies of transabdominal oral contrast-enhanced US were 88%, 86%, and 98%, respectively, and those of transverse contrast-enhanced CT were 93%, 83%, and 90%. The overall accuracy of transabdominal oral contrast-enhanced US was comparable with that of transverse contrast-enhanced CT for preoperative tumor staging of advanced gastric cancer. © 2017 by the American Institute of Ultrasound in Medicine.

  15. Association Between Preoperative Nutritional Status and Postoperative Outcome in Head and Neck Cancer Patients.

    Science.gov (United States)

    Leung, John S L; Seto, Alfred; Li, George K H

    2017-04-01

    Head and neck cancer patients treated with surgery often experience significant postoperative morbidities. Administering preoperative nutritional intervention may improve surgical outcomes, but there is currently a paucity of data reviewing the association between preoperative nutritional status and postoperative outcome. It is therefore of importance to investigate this association among head and neck cancer patients. To assess the association between preoperative nutritional status and postoperative outcome in head and neck cancer patients treated with surgery, a retrospective study of 70 head and neck cancer patients who were surgically treated between 2013 and 2014 in a tertiary referral head and neck surgery center in Hong Kong was conducted. Clinical data regarding preoperative nutritional status and postoperative outcome were retrieved from a computer record system. Logistic and linear regressions were used to analyze the appropriate parameters. A higher preoperative albumin level was associated with lower rates of postoperative complications and better wound healing (P cancer patients, preoperative intervention strategies that boost albumin levels could be considered for improving surgical outcome.

  16. Improving the detection of illicit substance use in preoperative anesthesiological assessment.

    Science.gov (United States)

    Kleinwächter, R; Kork, F; Weiss-Gerlach, E; Ramme, A; Linnen, H; Radtke, F; Lütz, A; Krampe, H; Spies, C D

    2010-01-01

    Illicit substance use (ISU) is a worldwide burden, and its prevalence in surgical patients has not been well investigated. Co-consumption of legal substances, such as alcohol and tobacco, complicates the perioperative management and is frequently underestimated during routine preoperative assessment. The aim of this study was to compare the anesthesiologists' detection rate of ISU during routine preoperative assessment with a computerized self-assessment questionnaire. In total, 2,938 patients were included in this study. Prior to preoperative assessment, patients were asked to complete a computer-based questionnaire that addressed ISU, alcohol use disorder (AUDIT), nicotine use (Fagerström) and socio-economic variables (education, income, employment, partnership and size of household). Medical records were reviewed, and the anesthesiologists' detection of ISU was compared to the patients' self-reported ISU. Seven point five percent of patients reported ISU within the previous twelve months. ISU was highest in the age group between 18 and 30 years (26.4%; P<0.01). Patients reporting ISU were more often men than women (P<0.01), smokers (P<0.01) and tested positive for alcohol use disorder (P<0.01). Anesthesiologists detected ISU in one in 43 patients, whereas the computerized self-assessment reported it in one in 13 patients. The detection was best in the subgroup self-reporting frequent ISU (P<0.01). Anesthesiologists underestimate the prevalence of ISU. Computer-based self-assessment increases the detection of ISU in preoperative assessment and may decrease perioperative risk. More strategies to improve the detection of ISU as well as brief interventions for ISU are required in preoperative assessment clinics.

  17. Preoperative CT evaluation of adenocarcinoma of the gastroesophageal junction

    International Nuclear Information System (INIS)

    Bennett, J.D.; Lefcoe, M.S.; Finley, R.; Yoshi, C.; Inculet, R.

    1988-01-01

    A retrospective review was undertaken of 53 preoperative computed tomographic (CT) scans obtained between March 1983 and April 1988 from patients undergoing surgery for adenocarcinoma of the gastroesophageal junction, and results were correlated with the surgical-pathologic findings. CT was unreliable in predicting aortic, pericardial, or pancreatic invasion (sensitivity, 0/8; specificity, 41/45). Of 45 pathologically positive nodal groups, the largest node measured on CT scans was 10 mm or less in 36 cases. The accuracy of preoperative CT in staging adenocarcinoma of the gastroesophageal junction is limited by its low sensitivity in detecting local invasion. Nodal size as measured with CT is not a reliable indicator of metastatic disease

  18. Preoperative evaluation of hilar vessel anatomy with 3-D computerized tomography in living kidney donors.

    Science.gov (United States)

    Tombul, S T; Aki, F T; Gunay, M; Inci, K; Hazirolan, T; Karcaaltincaba, M; Erkan, I; Bakkaloglu, A; Yasavul, U; Bakkaloglu, M

    2008-01-01

    Digital subtract angiography is the gold standard for anatomic assessment of renal vasculature for living renal donors. However, multidetector-row computerized tomography (MDCT) is less invasive than digital subtract angiography and provides information of kidney stones and other intra-abdominal organs. In this study, preoperative MDCT angiography results were compared with the peroperative findings to evaluate the accuracy of MDCT for the evaluation of renal anatomy. From December 2002 to May 2007, all 60 consecutive living kidney donors were evaluated with MDCT angiography preoperatively. We reported the number and origin of renal arteries, presence of early branching arteries, and any intrinsic renal artery disease. Renal venous anatomy was evaluated for the presence of accessory, retroaortic, and circumaortic veins using venous phase axial images. The calyces and ureters were assessed with delayed topograms. The results of the MDCT angiography were compared with the peroperative findings. A total of 67 renal arteries were seen peroperatively in 60 renal units. Preoperative MDCT angiography detected 64 of them. The two arteries not detected by MDCT had diameters less than 3 mm. Anatomic variations were present in nine veins, five of which were detected by CT angiography. Sensitivity of MDCT angiography for arteries and veins was 95% and 93%, respectively. Positive predictive values were 100% for both arteries and veins. MDCT angiography offers a less invasive, rapid, and accurate preoperative investigation modality for vascular anatomy in living kidney donors. It also provides sufficient information about extrarenal anatomy important for donor surgery.

  19. Axial myopathy

    DEFF Research Database (Denmark)

    Witting, Nanna; Andersen, Linda K; Vissing, John

    2016-01-01

    Classically, myopathies are categorized according to limb or cranial nerve muscle affection, but with the growing use of magnetic resonance imaging it has become evident that many well-known myopathies have significant involvement of the axial musculature. New disease entities with selective axial...

  20. Axial sesamoiditis in the horse: A review

    Directory of Open Access Journals (Sweden)

    Christelle Le Roux

    2018-03-01

    Full Text Available Axial sesamoiditis or osteitis of the proximal sesamoid bones (PSBs in the horse is described as a rare condition. The cause remains unknown and speculative, with vascular, infectious, and traumatic aetiologies implicated. It is specifically associated with injury of the palmar or plantar ligament (PL, also known as the intersesamoidean ligament. Imaging findings are generally rewarding and radiological changes are typical, if not pathognomonic, for the condition. Lesions consist of bone lysis at the apical to mid-body axial margins of the PSBs, with variable degrees of joint effusion. Radiographic technique warrants careful attention to make a diagnosis, and exposure factors may need to be adjusted. Perineural, intra-articular and intra-thecal anaesthesia does not seem to provide consistent improvement of lameness in these cases, with literature reporting inconsistent findings. Ultrasonographic findings include digital flexor sheath effusion, loss of the normal fibre structure of the PL at its attachment to the PSBs, abnormal echogenicity or change in thickness of the PL, and irregular hyperechoic cortical margins of the axial margins of the PSBs. Scintigraphy, computed tomography and magnetic resonance imaging, although not necessary to make a diagnosis, may add valuable information regarding the location and extent of lesions. The prognosis remains guarded to poor for return to athletic function. The focus of this paper is a comprehensive review of the proposed aetiopathogenesis of the condition, the prognosis, and a summary of the literature findings with focus on the notable diagnostic imaging features, including radiography, ultrasonography, scintigraphy, computed tomography and magnetic resonance imaging.

  1. Clinico-statistical study of preoperative examination for the dental implant using multi-detector row computed tomography

    International Nuclear Information System (INIS)

    Sekiya, Keiko; Mori, Shintaro; Sekiya, Kotaro

    2008-01-01

    In April 2006, a new affiliated hospital opened at Nihon University School of Dentistry at Matsudo, and the latest model was introduced into the department of radiology. CT examinations for preoperative dental implant going on 64 multi-detector row CT, the number of cases has increased. CT examination is useful for preoperative dental implant, and many studies of concerning clinical studies using CT images have been reported. The purpose of this study was to the clinico-statistical studies of preoperative CT examinations for dental implant at our radiology department using 64 multi-detector row CT. The subjects consisted of 5174 regions in 1312 cases of preoperative CT examinations, between April 2006 and December 2007. CT machine used was the Aquilion TM 64 (Toshiba Medical Systems, Japan), and the workstation used was the ZIOSTATION (ZIOSOFT, Japan). All of CT examinations were performed the position of implant placement and disease examined from CT findings. The following results were obtained: The 1312 cases consisted of 426 males and 886 females. Patient age ranged from 16 yrs to 86 yrs old, the average age were 55.5 yrs old. Six hundred and seventy four cases were ordered at another private dental office not our hospital, and 638 cases were ordered at our hospital. The numbers of implant placement were on the average of 3.9, and the rate got higher with age. The lesions which detected by preoperative CT examination were maxillary sinusitis, periodontitis, ectopic calcification, and mucous retention cyst. (author)

  2. Axial Hall effect and universality of holographic Weyl semi-metals

    Energy Technology Data Exchange (ETDEWEB)

    Copetti, Christian; Fernández-Pendás, Jorge; Landsteiner, Karl [Instituto de Física Teórica UAM/CSIC,c/ Nicolás Cabrera 13-15, Cantoblanco, 28049 Madrid (Spain)

    2017-02-28

    The holographic Weyl semimetal is a model of a strongly coupled topological semi-metal. A topological quantum phase transition separates a topological phase with non-vanishing anomalous Hall conductivity from a trivial state. We investigate how this phase transition depends on the parameters of the scalar potential (mass and quartic self coupling) finding that the quantum phase transition persists for a large region in parameter space. We then compute the axial Hall conductivity. The algebraic structure of the axial anomaly predicts it to be 1/3 of the electric Hall conductivity. We find that this holds once a non-trivial renormalization effect on the external axial gauge fields is taken into account. Finally we show that the phase transition also occurs in a top-down model based on a consistent truncation of type IIB supergravity.

  3. Preoperative evaluation

    International Nuclear Information System (INIS)

    Murphy, C.H.; Murphy, M.R.

    1987-01-01

    The value of a preoperative chest radiograph is twofold. The examination may reveal unsuspected pathology that would alter the approach to surgery of anesthesia. Secondly, it provides a baseline or reference from which to evaluate subsequent post-operative films. The percentage of detection of unsuspected pathology on preoperative chest radiographs has been shown to be exceedingly small in certain patient populations. The authors do not recommend routine use of preoperative chest radiographs in children or in adults under the age of 40 who do not smoke, unless (1) the surgical disease has chest manifestations; (2) there is historic or clinical evidence of a coexisting disease with chest involvement; or (3) there is a likelihood that post-operative management will require follow-up films

  4. Discrete Element Simulations and Experiments on the Deformation of Cohesive Powders in a Bi-Axial Box

    NARCIS (Netherlands)

    Imole, Olukayode Isaiah; Kumar, Nishant; Magnanimo, Vanessa; Luding, Stefan

    2012-01-01

    We compare element test experiments and simulations on the deformation of frictional, cohesive particles in a bi-axial box. We show that computer simulations with the Discrete Element Method qualitatively reproduce a uniaxial compression element test in the true bi-axial tester. We highlight the

  5. Detection of ossicular chain abnormalities using CT imaging. Comparison of axial and virtual middle ear endoscopic imaging

    International Nuclear Information System (INIS)

    Sakata, Motomichi; Kamagata, Masaki; Harada, Kuniaki; Shirase, Ryuji; Oomoto, Hidechika; Himi, Tetsuo

    2000-01-01

    The purpose of this study was to evaluate the usefulness of axial and three-dimensional imaging (virtual endoscopy) with helical CT for the detection of ossicular chain abnormalities. In 15 patients who had traumatic ossicular dislocation, disruption, and congenital ossicular defect and anomaly, axial helical CT scanning of the temporal bone was performed with GE HSA. Axial and three-dimensional imaging was carried out in normal ears (15 ears) and abnormal ears (10 ears), for the detection of ossicular chain abnormalities. Diagnostic accuracy was evaluated by receiver-operating-characteristic (ROC) curve analysis using a continuous reporting scale. Furthermore, ROC testing was done to determine the sensitivity, specificity, and accuracy of the detection of ossicular chain abnormalities. Diagnostic accuracy in the detection of ossicular chain abnormalities with three-dimensional imaging (A z =0.967, SD=0.022) was not significantly better than that of axial imaging (A z =0.930, SD=0.046); however, the interobserver standard deviation was better for three-dimensional imaging. Three-dimensional imaging resulted in an increase in true positive cases and a decrease in false negatives. Three-dimensional imaging also showed higher sensitivity and accuracy. In the evaluation of ossicular chain abnormalities, three-dimensional imaging (virtual endoscopy) is useful and provides additional information. Three-dimensional imaging may have an important role in diagnostic procedures and/or preoperative evaluation in otology. (author)

  6. Does preoperative measurement of cerebral blood flow with acetazolamide challenge in addition to preoperative measurement of cerebral blood flow at the resting state increase the predictive accuracy of development of cerebral hyperperfusion after carotid endarterectomy? Results from 500 cases with brain perfusion single-photon emission computed tomography study.

    Science.gov (United States)

    Oshida, Sotaro; Ogasawara, Kuniaki; Saura, Hiroaki; Yoshida, Koji; Fujiwara, Shunro; Kojima, Daigo; Kobayashi, Masakazu; Yoshida, Kenji; Kubo, Yoshitaka; Ogawa, Akira

    2015-01-01

    The purpose of the present study was to determine whether preoperative measurement of cerebral blood flow (CBF) with acetazolamide in addition to preoperative measurement of CBF at the resting state increases the predictive accuracy of development of cerebral hyperperfusion after carotid endarterectomy (CEA). CBF at the resting state and cerebrovascular reactivity (CVR) to acetazolamide were quantitatively assessed using N-isopropyl-p-[(123)I]-iodoamphetamine (IMP)-autoradiography method with single-photon emission computed tomography (SPECT) before CEA in 500 patients with ipsilateral internal carotid artery stenosis (≥ 70%). CBF measurement using (123)I-IMP SPECT was also performed immediately and 3 days after CEA. A region of interest (ROI) was automatically placed in the middle cerebral artery territory in the affected cerebral hemisphere using a three-dimensional stereotactic ROI template. Preoperative decreases in CBF at the resting state [95% confidence intervals (CIs), 0.855 to 0.967; P = 0.0023] and preoperative decreases in CVR to acetazolamide (95% CIs, 0.844 to 0.912; P state (difference between areas, 0.173; P state (P state increases the predictive accuracy of the development of post-CEA hyperperfusion.

  7. Preoperative evaluation of liver volume parameters in living related donors by spiral computed tomography

    International Nuclear Information System (INIS)

    Michalak, M.; Pacho, R.; Pruszynski, B.; Paluszkiewicz, R.; Hevelke, P.; Krawczyk, M.

    2002-01-01

    The objective of the study is to assess the use of spiral computed tomography in the evaluation of the volume of the liver, its lobes, and selected segments in the preoperative period and to validate the used measurements. Thirty five potential donors (15 women and 20 men) aged 21-65 years were included. Based on the CT liver findings in the venous-portal phase and segment division of the liver according Couinaud the liver volume was calculated manually be a planimetric method, after making outlines of all liver sections. The volumes of lobes and selected segments were assessed by the same technique. The volumes of the resected liver segments calculated based on the CT findings were compared with appropriate measurements made during the operation. The total liver volume ranged between 804 and 1842 cm 3 (mean - 1456 cm 3 , standard deviation [SD] - 247). The volume of the right liver lobe including caudate lobe was 555 cm 3 to 1382 cm 3 (mean - 1024, SD - 186) that is in average 70.4% of the total liver volume. The volume of the left liver lobe ranged between 156 and 778 cm 3 (mean - 431, SD - 123) that is in average 29.6% of the total liver volume. The volume of segments 2+3 was 72 to 426 cm 3 (mean - 237 cm 3 , SD - 79) that is in average 16.2% of the total liver volume. The volume of the segment 4 ranged between 84 and 366 cm 3 (mean - 196, SD - 70) that is in average 13.4% of the total liver volume. CT makes possible to assess the volume of the liver, of its lobes and selected segments and it is an important modality for the classification of method of operation (segmentectomy, left hepatectomy, right hepatectomy). This method is accurate and reproducible. The liver part volumes calculated preoperatively in the majority of cases revealed to be smaller than in reality in average of 12.1%. (author)

  8. Numerical Simulation of single-stage axial fan operation under dusty flow conditions

    Science.gov (United States)

    Minkov, L. L.; Pikushchak, E. V.

    2017-11-01

    Assessment of the aerodynamic efficiency of the single-stage axial flow fan under dusty flow conditions based on a numerical simulation using the computational package Ansys-Fluent is proposed. The influence of dust volume fraction on the dependences of the air volume flow rate and the pressure drop on the rotational speed of rotor is demonstrated. Matching functions for formulas describing a pressure drop and volume flow rate in dependence on the rotor speed and dust content are obtained by numerical simulation for the single-stage axial fan. It is shown that the aerodynamic efficiency of the single-stage axial flow fan decreases exponentially with increasing volume content of dust in the air.

  9. A molecular computational model improves the preoperative diagnosis of thyroid nodules

    International Nuclear Information System (INIS)

    Tomei, Sara; Marchetti, Ivo; Zavaglia, Katia; Lessi, Francesca; Apollo, Alessandro; Aretini, Paolo; Di Coscio, Giancarlo; Bevilacqua, Generoso; Mazzanti, Chiara

    2012-01-01

    Thyroid nodules with indeterminate cytological features on fine needle aspiration (FNA) cytology have a 20% risk of thyroid cancer. The aim of the current study was to determine the diagnostic utility of an 8-gene assay to distinguish benign from malignant thyroid neoplasm. The mRNA expression level of 9 genes (KIT, SYNGR2, C21orf4, Hs.296031, DDI2, CDH1, LSM7, TC1, NATH) was analysed by quantitative PCR (q-PCR) in 93 FNA cytological samples. To evaluate the diagnostic utility of all the genes analysed, we assessed the area under the curve (AUC) for each gene individually and in combination. BRAF exon 15 status was determined by pyrosequencing. An 8-gene computational model (Neural Network Bayesian Classifier) was built and a multiple-variable analysis was then performed to assess the correlation between the markers. The AUC for each significant marker ranged between 0.625 and 0.900, thus all the significant markers, alone and in combination, can be used to distinguish between malignant and benign FNA samples. The classifier made up of KIT, CDH1, LSM7, C21orf4, DDI2, TC1, Hs.296031 and BRAF had a predictive power of 88.8%. It proved to be useful for risk stratification of the most critical cytological group of the indeterminate lesions for which there is the greatest need of accurate diagnostic markers. The genetic classification obtained with this model is highly accurate at differentiating malignant from benign thyroid lesions and might be a useful adjunct in the preoperative management of patients with thyroid nodules

  10. Organo-axial volvulus of the small intestine: radiological case report and consideration for its mechanism.

    Science.gov (United States)

    Ishiguro, Toshitaka; Hiyama, Takashi; Nasu, Katsuhiro; Akashi, Yoshimasa; Minami, Manabu

    2017-07-01

    Gastrointestinal volvulus is mainly classified into two subtypes, mesentero-axial volvulus and organo-axial volvulus. The detailed imaging findings of organo-axial volvulus of the small intestine have never been reported as far as we know. In this article, we report a case of organo-axial volvulus of the small intestine, focusing on the computed tomography (CT) findings. An 80-year-old man was radiologically diagnosed as having organo-axial volvulus of the terminal ileum and it was confirmed by open surgery without adhesion or any other anatomical abnormalities. CT showed two specific findings, split-bowel sign and rotating-C sign, which we think reflect pathophysiologic features of organo-axial volvulus. We think the pathogenic mechanism of organo-axial volvulus can be explained by the convergence of the reversed-rotational twist following the formation of a twisted but non-obstructive circular loop, even if there is no adhesion. Radiologists should be aware that organo-axial volvulus can occur even in the small intestine, and in the case of small bowel obstruction with single transition point, the two pathophysiologic signs mentioned above must be looked for to diagnose the possibility of organo-axial volvulus.

  11. The reliability of cone-beam computed tomography to assess bone density at dental implant recipient sites: a histomorphometric analysis by micro-CT.

    Science.gov (United States)

    González-García, Raúl; Monje, Florencio

    2013-08-01

    The aim of this study was to objectively assess the reliability of the cone-beam computed tomography (CBCT) as a tool to pre-operatively determine radiographic bone density (RBD) by the density values provided by the system, analyzing its relationship with histomorphometric bone density expressed as bone volumetric fraction (BV/TV) assessed by micro-CT of bone biopsies at the site of insertion of dental implants in the maxillary bones. Thirty-nine bone biopsies of the maxillary bones at the sites of 39 dental implants from 31 edentulous healthy patients were analyzed. The NobelGuide™ software was used for implant planning, which also allowed fabrication of individual stereolithographic surgical guides. The analysis of CBCT images allowed pre-operative determination of mean density values of implant recipient sites along the major axis of the planned implants (axial RBD). Stereolithographic surgical guides were used to guide implant insertion and also to extract cylindrical bone biopsies from the core of the exact implant site. Further analysis of several osseous micro-structural variables including BV/TV was performed by micro-CT of the extracted bone biopsies. Mean axial RBD was 478 ± 212 (range: 144-953). A statistically significant difference (P = 0.02) was observed among density values of the cortical bone of the upper maxilla and mandible. A high positive Pearson's correlation coefficient (r = 0.858, P micro-CT at the site of dental implants in the maxillary bones. Pre-operative estimation of density values by CBCT is a reliable tool to objectively determine bone density. © 2012 John Wiley & Sons A/S.

  12. Sclerosing encapsulating peritonitis in chronic ambulatory peritoneal dialysis;preoperative catheter drainage : a case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hoon [Dankook Univ. Hospital, Seoul (Korea, Republic of)

    1996-10-01

    Sclerosing encapsulating peritonitis is a well recognized, but uncommon, complication of chronic ambulatory peritoneal dialysis. I report a case of sclerosing encapsulating peritonitis in which percutaneous catheter drainage was performed preoperatively. Ultrasonography(US) and computed tomography(CT) showed a large multi-septated cystic mass which occupied nearly all the peritoneal cavity. Percutaneous drainage with two 8.5 French catheters was preoperatively performed under fluoroscopy and about 2100 ml of bloody fluid was drained for 20 days. On follow-up CT, the size of the cyst had significantly decreased and anoperation was performed. It is considered that percutaneous catheter drainage is useful in the preoperative decompression of sclerosing encapsulating peritonitis.

  13. Sclerosing encapsulating peritonitis in chronic ambulatory peritoneal dialysis;preoperative catheter drainage : a case report

    International Nuclear Information System (INIS)

    Kim, Tae Hoon

    1996-01-01

    Sclerosing encapsulating peritonitis is a well recognized, but uncommon, complication of chronic ambulatory peritoneal dialysis. I report a case of sclerosing encapsulating peritonitis in which percutaneous catheter drainage was performed preoperatively. Ultrasonography(US) and computed tomography(CT) showed a large multi-septated cystic mass which occupied nearly all the peritoneal cavity. Percutaneous drainage with two 8.5 French catheters was preoperatively performed under fluoroscopy and about 2100 ml of bloody fluid was drained for 20 days. On follow-up CT, the size of the cyst had significantly decreased and anoperation was performed. It is considered that percutaneous catheter drainage is useful in the preoperative decompression of sclerosing encapsulating peritonitis

  14. Axial-Flow Turbine Rotor Discharge-Flow Overexpansion and Limit-Loading Condition, Part I: Computational Fluid Dynamics (CFD) Investigation

    Science.gov (United States)

    Chen, Shu-Cheng S.

    2017-01-01

    A Computational Fluid Dynamic (CFD) investigation is conducted over a two-dimensional axial-flow turbine rotor blade row to study the phenomena of turbine rotor discharge flow overexpansion at subcritical, critical, and supercritical conditions. Quantitative data of the mean-flow Mach numbers, mean-flow angles, the tangential blade pressure forces, the mean-flow mass flux, and the flow-path total pressure loss coefficients, averaged or integrated across the two-dimensional computational domain encompassing two blade-passages, are obtained over a series of 14 inlet-total to exit-static pressure ratios, from 1.5 (un-choked; subcritical condition) to 10.0 (supercritical with excessively high pressure ratio.) Detailed flow features over the full domain-of-computation, such as the streamline patterns, Mach contours, pressure contours, blade surface pressure distributions, etc. are collected and displayed in this paper. A formal, quantitative definition of the limit loading condition based on the channel flow theory is proposed and explained. Contrary to the comments made in the historical works performed on this subject, about the deficiency of the theoretical methods applied in analyzing this phenomena, using modern CFD method for the study of this subject appears to be quite adequate and successful. This paper describes the CFD work and its findings.

  15. Non-small cell lung cancer: Spectral computed tomography quantitative parameters for preoperative diagnosis of metastatic lymph nodes

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Fengfeng [Department of Radiology, The Fourth Affiliated Hospital, Harbin Medical University, Harbin 150001 (China); Dong, Jie [Department of Geriatrics, The First Affiliated Hospital, Harbin Medical University, Harbin 150001 (China); Wang, Xiuting; Fu, Xiaojiao [Department of Radiology, The Fourth Affiliated Hospital, Harbin Medical University, Harbin 150001 (China); Zhang, Tong, E-mail: zt415@sina.com [Department of Radiology, The Fourth Affiliated Hospital, Harbin Medical University, Harbin 150001 (China)

    2017-04-15

    Objective: To investigate the application value of spectral computed tomography (CT)quantitative parameters for preoperative diagnosis of metastatic lymph nodes in patients with non-small cell lung cancer (NSLC). Methods: 84 patients with suspected lung cancer who underwent chest dual-phase enhanced scan with gemstone spectral CT imaging (GSI) mode were selected. GSI quantitative parameters including normalized iodine concentrations (NIC), water concentration, slope of the spectral Hounsfield unit curve (λHU) were measured. The two-sample t test was used to statistically compare these quantitative parameters. Receiver operating characteristic (ROC) curves were drawn to establish the optimal threshold values. Results: A total of 144 lymph nodes were included, with 48 metastatic lymph nodes and 96 non-metastatic lymph nodes. The slope of the spectral Hounsfeld unit curve (λHU) measured during both arterial and venous phases were signifcantly higher in metastatic than in benign lymph nodes (P < 0.05). The area under the ROC curve (AUC = 0.951) of λHU of the arterial phase (AP) was the largest. When the optimal threshold values of λHU was 2.75, the sensitivity, specificity, and overall accuracy in the diagnosis of metastatic lymph nodes were 88.2%, 88.4%, 87.0%, respectively. Conclusion: Conventional CT diagnostic criteria established in accordance with size (lymph node maximal short axis diameter ≥10 mm) as the basis for judging metastatic lymph node. In quantitative assessment using spectral CT imaging, quantitative parameters showed higher accuracy than qualitative assessment of conventional CT based on the size for preoperative diagnosis of metastatic lymph nodes.

  16. Spectroscopic and computational studies of cobalamin species with variable lower axial ligation: implications for the mechanism of Co-C bond activation by class I cobalamin-dependent isomerases.

    Science.gov (United States)

    Conrad, Karen S; Jordan, Christopher D; Brown, Kenneth L; Brunold, Thomas C

    2015-04-20

    5'-deoxyadenosylcobalamin (coenzyme B12, AdoCbl) serves as the cofactor for several enzymes that play important roles in fermentation and catabolism. All of these enzymes initiate catalysis by promoting homolytic cleavage of the cofactor's Co-C bond in response to substrate binding to their active sites. Despite considerable research efforts, the role of the lower axial ligand in facilitating Co-C bond homolysis remains incompletely understood. In the present study, we characterized several derivatives of AdoCbl and its one-electron reduced form, Co(II)Cbl, by using electronic absorption and magnetic circular dichroism spectroscopies. To complement our experimental data, we performed computations on these species, as well as additional Co(II)Cbl analogues. The geometries of all species investigated were optimized using a quantum mechanics/molecular mechanics method, and the optimized geometries were used to compute absorption spectra with time-dependent density functional theory. Collectively, our results indicate that a reduction in the basicity of the lower axial ligand causes changes to the cofactor's electronic structure in the Co(II) state that replicate the effects seen upon binding of Co(II)Cbl to Class I isomerases, which replace the lower axial dimethylbenzimidazole ligand of AdoCbl with a protein-derived histidine (His) residue. Such a reduction of the basicity of the His ligand in the enzyme active site may be achieved through proton uptake by the catalytic triad of conserved residues, DXHXGXK, during Co-C bond homolysis.

  17. Primary muscular hydatid: preoperative diagnosis Throught computerized tomography and ultrasonography

    International Nuclear Information System (INIS)

    Macho Fernandez, J.M.; Marin Cardenas, M.A.; Mazas Artasona, L.; Lample Lacasa, C.; Otero Sierra, C.; Hernandez Navarrete, M.J.; Gomez-Pereda, R.

    1995-01-01

    Primary muscular hydatid disease, is extremely rare,- but not exceptional-, comparatively with other atypical localization. In this article the authors revised 474 patients with hydatid disease over a ten years period. Three cases of primary muscular localization were found. The ultrasonography and computed tomography facilitates the preoperative diagnosis. (Author) 40 refs

  18. A study of friction and axial effects in pellet-clad mechanical interaction

    International Nuclear Information System (INIS)

    Harriague, Santiago; Mayer, J.E.

    1982-01-01

    An analysis is made of the effect of friction and axial forces along the fuel rod in the pellet-cladding mechanical interaction in a commercial reactor under a power-up ramp. The effect of different pellet and rod shapes on their behaviour was also determined. A linear thermoelastic computer program was used in order to obtain the stiffness matrix of a compound structure from the stiffness of its components. Pellet-cladding displacements, localized deformations of the cladding in the interfaces between pellets, as well as pellet and cladding axial deformations were determined for different power axial profiles as well as for pellets with and without dishing and with height/diameter ratios of 1.7, 1 and 0.5. (M.E.L.) [es

  19. [Preoperative structured patient education].

    Science.gov (United States)

    Lamarche, D

    1993-04-01

    This article describes the factors that motivated the nursing staff of the cardiac surgery unit at the Royal Victoria Hospital in Montreal, to revise their preoperative teaching program. The motivating factors described are the length of the preoperative waiting period; the level of preoperative anxiety; the decreased length of hospital stay; the dissatisfaction of the nursing staff with current patient teaching practices; and the lack of available resources. The reorganization of the teaching program was based upon the previously described factors combined with a review of the literature that demonstrated the impact of preoperative anxiety, emotional support and psycho-educational interventions upon the client's recovery. The goals of the new teaching program are to provide the client and the family with cognitive and sensory information about the client's impending hospitalization, chronic illness and necessary lifestyle modifications. The program consists of a system of telephone calls during the preoperative waiting period; a videotape viewing; a tour of the cardiac surgery unit; informal discussion groups; and the availability of nursing consultation to decrease preoperative anxiety. The end result of these interventions is more time for client support and integration of necessary information by the client and family. This kind of program has the potential to provide satisfaction at many levels by identifying client's at risk; increasing client knowledge; increasing support; decreasing anxiety during the preoperative waiting period; and decreasing the length of hospital stay. The nursing staff gained a heightened sense of accomplishment because the program was developed according to the nursing department's philosophy, which includes primary nursing.(ABSTRACT TRUNCATED AT 250 WORDS)

  20. Accuracy of preoperative urinary symptoms, urinalysis, computed tomography and cystoscopic findings for the diagnosis of urinary bladder invasion in patients with colorectal cancer.

    Science.gov (United States)

    Woranisarakul, Varat; Ramart, Patkawat; Phinthusophon, Kittipong; Chotikawanich, Ekkarin; Prapasrivorakul, Siriluck; Lohsiriwat, Varut

    2014-01-01

    To determine the accuracy of preoperative urinary symptoms, urinalysis, computed tomography (CT) and cystoscopic findings for the diagnosis of urinary bladder invasion in patients with colorectal cancer. Records of patients with colorectal cancer and a suspicion of bladder invasion, who underwent tumor resection with partial or total cystectomy between 2002 and 2013 at the Faculty of Medicine Siriraj Hospital, were reviewed. Correlations between preoperative urinary symptoms, urinalysis, cystoscopic finding, CT imaging and final pathological reports were analyzed. This study included 90 eligible cases (71% male). The most common site of primary colorectal cancer was the sigmoid colon (44%), followed by the rectum (33%). Final pathological reports showed definite bladder invasion in 53 cases (59%). Significant features for predicting definite tumor invasion were gross hematuria (OR 13.6, sensitivity 39%, specificity 73%), and visible tumor during cystoscopy (OR 5.33, sensitivity 50%, specificity 84%). Predictive signs in CT imaging were gross tumor invasion (OR 7.07, sensitivity 89%, specificity 46%), abnormal enhancing mass at bladder wall (OR 4.09, sensitivity 68%, specificity 66%), irregular bladder mucosa (OR 3.53, sensitivity 70%, specificity 60% ), and loss of perivesical fat plane (OR 3.17, sensitivity 81%, specificity 43%). However, urinary analysis and other urinary tract symptoms were poor predictors of bladder involvement. The present study demonstrated that the most relevant preoperative predictors of definite bladder invasion in patients with colorectal cancer are gross hematuria, a visible tumor during cystoscopy, and abnormal CT findings.

  1. A molecular computational model improves the preoperative diagnosis of thyroid nodules

    Directory of Open Access Journals (Sweden)

    Tomei Sara

    2012-09-01

    Full Text Available Abstract Background Thyroid nodules with indeterminate cytological features on fine needle aspiration (FNA cytology have a 20% risk of thyroid cancer. The aim of the current study was to determine the diagnostic utility of an 8-gene assay to distinguish benign from malignant thyroid neoplasm. Methods The mRNA expression level of 9 genes (KIT, SYNGR2, C21orf4, Hs.296031, DDI2, CDH1, LSM7, TC1, NATH was analysed by quantitative PCR (q-PCR in 93 FNA cytological samples. To evaluate the diagnostic utility of all the genes analysed, we assessed the area under the curve (AUC for each gene individually and in combination. BRAF exon 15 status was determined by pyrosequencing. An 8-gene computational model (Neural Network Bayesian Classifier was built and a multiple-variable analysis was then performed to assess the correlation between the markers. Results The AUC for each significant marker ranged between 0.625 and 0.900, thus all the significant markers, alone and in combination, can be used to distinguish between malignant and benign FNA samples. The classifier made up of KIT, CDH1, LSM7, C21orf4, DDI2, TC1, Hs.296031 and BRAF had a predictive power of 88.8%. It proved to be useful for risk stratification of the most critical cytological group of the indeterminate lesions for which there is the greatest need of accurate diagnostic markers. Conclusion The genetic classification obtained with this model is highly accurate at differentiating malignant from benign thyroid lesions and might be a useful adjunct in the preoperative management of patients with thyroid nodules.

  2. Numerical simulation of the tip clearance flow in axial turbomachinery; Numerische Simulation der Stroemung im radialen Schaufelspalt axialer Turbomaschinen

    Energy Technology Data Exchange (ETDEWEB)

    Melake, A [Deutsche Forschungsanstalt fuer Luft- und Raumfahrt e.V. (DLR), Koeln (Germany). Inst. fuer Antriebstechnik

    1997-12-31

    A computer program has been developed to calculate the three-dimensional tip leakage flow in axial turbomachinery based on the Navier-Stokes equation. This program has been applied to investigate the leakage flow within the gap between the blade fip and casing in an annular compressor cascade. A block structured computational mesh has been used in order to resolve the flow details within the gap and the passage flow. Flow characteristics like boundary layer separation, vortex genesis and interaction of the leakage flow with the secondary flow have been investigated and compared with existing experimental data. By varying the incidence angle and the tip gap the above mentioned flow phenomena have been analysed in an annular compressor cascade and a shrouded propfan rotor respectively. Furthermore, the relationship between the total pressure loss, the axial velocity deficit and the divergence of the tip leakage vortex has been investigated. Streamlines, limited streamlines and the critical point theory have been used extensively to analyse the boundary layer separation on the casing and its roll up to form the tip clearance vortex. (orig.). 59 figs., 3 tabs., 110 refs. [Deutsch] Es wurde ein Rechenprogramm zur Berechnung der dreidimensionalen Spaltstroemung im radialen Schaufelspalt axialer Turbomaschinen auf der Basis der Navier-Stokes`schen Gleichungen entwickelt und angewendet. Um die Stroemung innerhalb des Spaltes und der Schaufelpassage besser aufloesen zu koennen, wurde eine blockstrukturierte Netztopologie verwendet. Stroemungseigenschaften wie Grenzschichtabloesung, Entstehung des Spaltwirbels, Interaktion der Spaltstroemung mit der Sekundaerstroemung werden untersucht und mit vorhandenen experimentellen Daten verglichen. Im weiteren werden durch Variation der Inzidenz und der Spaltweite die oben genannten Stroemungsphaenomene an einem axialen Verdichterringgitter und an einem ummantelten Propfan analysiert. Ferner werden die Korrelation zwischen

  3. Novel prediction model of renal function after nephrectomy from automated renal volumetry with preoperative multidetector computed tomography (MDCT).

    Science.gov (United States)

    Isotani, Shuji; Shimoyama, Hirofumi; Yokota, Isao; Noma, Yasuhiro; Kitamura, Kousuke; China, Toshiyuki; Saito, Keisuke; Hisasue, Shin-ichi; Ide, Hisamitsu; Muto, Satoru; Yamaguchi, Raizo; Ukimura, Osamu; Gill, Inderbir S; Horie, Shigeo

    2015-10-01

    The predictive model of postoperative renal function may impact on planning nephrectomy. To develop the novel predictive model using combination of clinical indices with computer volumetry to measure the preserved renal cortex volume (RCV) using multidetector computed tomography (MDCT), and to prospectively validate performance of the model. Total 60 patients undergoing radical nephrectomy from 2011 to 2013 participated, including a development cohort of 39 patients and an external validation cohort of 21 patients. RCV was calculated by voxel count using software (Vincent, FUJIFILM). Renal function before and after radical nephrectomy was assessed via the estimated glomerular filtration rate (eGFR). Factors affecting postoperative eGFR were examined by regression analysis to develop the novel model for predicting postoperative eGFR with a backward elimination method. The predictive model was externally validated and the performance of the model was compared with that of the previously reported models. The postoperative eGFR value was associated with age, preoperative eGFR, preserved renal parenchymal volume (RPV), preserved RCV, % of RPV alteration, and % of RCV alteration (p volumetry and clinical indices might yield an important tool for predicting postoperative renal function.

  4. Analysis of the flow dynamics characteristics of an axial piston pump based on the computational fluid dynamics method

    Directory of Open Access Journals (Sweden)

    Bin Zhang

    2017-01-01

    Full Text Available To improve its working performance, the flow ripple characteristics of an axial piston pump were investigated with software which uses computational fluid dynamics (CFD technology. The simulation accuracy was significantly optimized through the use of the improved compressible fluid model. Flow conditions of the pump were tested using a pump flow ripple test rig, and the simulation results of the CFD model showed good agreement with the experimental data. Additionally, the composition of the flow ripple was analyzed using the improved CFD model, and the results showed that the compression ripple makes up 88% of the flow ripple. The flow dynamics of the piston pump is mainly caused by the pressure difference between the intake and discharge ports of the valve plates and the fluid oil compressibility.

  5. Simple LMFBR axial-flow friction-factor correlation

    International Nuclear Information System (INIS)

    Chan, Y.N.; Todreas, N.E.

    1981-09-01

    Complicated LMFBR axial lead-length averaged friction factor correlations are reduced to an easy, ready-to-use function of bundle Reyonlds number for wire-wrapped bundles. The function together with the power curves to calculate the associated constants are incorporated in a computer pre-processor, EZFRIC. The constants required for the calculation of the subchannels and bundle friction factors are derived and correlated into power curves of geometrical parameters. A computer program, FRIC, which can alternatively be used to accurately calculate these constants is also included. The accuracte values of the constants and the corresponding values predicted by the power curves and percentage error of prediction are tabulated for a wide variety of geometries of interest

  6. Image reconstruction. Application to transverse axial tomography

    International Nuclear Information System (INIS)

    Aubry, Florent.

    1977-09-01

    A method of computerized tridimensional image reconstruction from their projection, especially in the computerized transverse axial tomography is suggested. First, the different techniques actually developped and presented in the literature are analyzed. Then, the equipment used is briefly described. The reconstruction algorithm developped is presented. This algorithm is based on the convolution method, well adapted to the real conditions of exploitation. It is an extension of SHEPP and LOGAN's algorithm. A correction of the self absorption and of the detector's response is proposed. Finally, the first results obtained which are satisfactory are given. The simplicity of the method which does not need a too long computation time makes possible the implementation of the algorithm on a mini-computer [fr

  7. The diagnostic value of multiplanar reconstruction on MDCT colonography for the preoperative staging of colorectal cancer

    International Nuclear Information System (INIS)

    Jin, Kwang Nam; Kim, Se Hyung; Lee, Jae Young; Lee, Jeong Min; Han, Joon Koo; Choi, Byung Ihn; Shin, Kyung-Sook

    2006-01-01

    The purpose of this study was to determine whether multiplanar reconstruction (MPR) images can improve the accuracy of MDCT-based colorectal cancer preoperative staging by receiver-operating characteristic (ROC) analysis. Fifty-five patients with colorectal cancer underwent contrast-enhanced CT colonography using an 8- or 16-row scanner. Two separate interval reviews of the axial MDCT datasets with/without MPR images (coronal and sagittal) were performed independently by two radiologists blinded to both the colonoscopic and histopathologic results. At each review session, the radiologists were asked to determine the colorectal cancer TNM stage within the context of differentiating ≤T3 from T4, N0 from ≥N1 and M0 from M1 using a five-point confidence scale. The radiologists' performance for staging the colorectal cancer using axial CT datasets with/without MPR images was evaluated using ROC analysis. Sensitivities, specificities and interobserver agreement were assessed. When MPR images were added, significant improvement was achieved by both radiologists for differentiating N0 from ≥N1 in terms of both A Z (0.651 to 0.769; 0.573 to 0.713) and specificity (26.7 to 69.2%; 23.1 to 76.9%) (P 0.05), but a significant improvement in the specificity (70 to 90%; 80 to 92%) was achieved by one radiologist (P<0.05). In terms of the M staging, a significant improvement in the Az (0.844 to 0.996) was observed for the combined interpretation of the axial and MPR images by one radiologist (P<0.05). Furthermore, substantial or almost perfect interobserver agreement was achieved for all TNM stagings for the combined interpretations (κ=0.641-0.866), whereas only fair to substantial agreement was achieved for the axial images alone (κ=0.337-0.707). In conclusion, the combined interpretation of the axial and MPR MDCT images significantly improved the local staging of colorectal cancer compared with assessments based on axial images alone. (orig.)

  8. Digital enhancement of computerized axial tomograms

    Science.gov (United States)

    Roberts, E., Jr.

    1978-01-01

    A systematic evaluation has been conducted of certain digital image enhancement techniques performed in image space. Three types of images have been used, computer generated phantoms, tomograms of a synthetic phantom, and axial tomograms of human anatomy containing images of lesions, artificially introduced into the tomograms. Several types of smoothing, sharpening, and histogram modification have been explored. It has been concluded that the most useful enhancement techniques are a selective smoothing of singular picture elements, combined with contrast manipulation. The most useful tool in applying these techniques is the gray-scale histogram.

  9. Evaluation of preoperative embolization of meningioma

    International Nuclear Information System (INIS)

    Park, Sung Tae; Suh, Dae Chul; Lee, Ho Kyu; Choi, Choong Gon; Lee, Myung Jun; Ji, Eun Kyung; Shin, Byung Suck; Kim, Chang Jin; Kim, Jong Uk; Whang, C. Jin

    1998-01-01

    To evaluate the efficacy and safety of preoperative embolization of intrancranial meningioma.Materials and Methods : We retrospectively reviewed intrancranial meningioma patients (n=37) who underwent preoperative embolization. They were categorized into two groups, skull base lesions (n=22) and non-skull base lesions (n=15), according to tumor location. In addition, embolization results were classified by comparison between pre- and post-embolization angiography as complete (residual tumor staining 10 or 30%). In each group, estimated blood loss (EBL) was estimated by amount of intraoperative transfusion with pre- and post-operative hemoglobin level. Tumor resectability was evaluated by follow-up computed tomography. New symptoms occurring within 24 hours of embolization were considered to be those associated with embolization ; symptoms improved by conservative treatment were regarded as mild, while those resulting in new deficits were considered severe. Results : In the group with skull base lesions (n=22), complete embolization with the criteria of residual tumor staining of less than 30% was performed in 14 patients(EBL=1770ml;complete surgical removal in nine patients and incomplete removal four). Incomplete embolization was performed in eight patients (EBL=3210ml; complete and incomplete removal each in four patients). In the group with non-skull base lesions, complete embolization with the criteria of residual tumor staining of less than 10% was performed in five patients (EBL=970ml) and incomplete embolization in ten (EBL=2260ml). Complete tumor removal was possible in this group regardless of the completeness of preoperative tumor embolization. In a case of intraventricular meningioma (3%), intratumoral hemorrhage occurred on the day following embolization. Other mild post-embolization complications occurred in three cases (8%). Conclusion : Preoperative embolization can be an effective and safe procedure for meningioma and may reduce intraoperative blood

  10. SENDS criteria from the diversification of MAST procedures. Implementation of preoperative simulation

    International Nuclear Information System (INIS)

    Rieger, B.

    2015-01-01

    Minimal access spinal technologies (MAST) lead to a diversification of surgical procedures, which requires careful selection of the procedure and outcome monitoring. For a rational selection of the procedure simulation, endoscopy, navigation, decompression and stabilization (SENDS) criteria can be derived from the development of the MAST procedures. Preoperative simulation has diagnostic and therapeutic values. The SENDS criteria can be verified indirectly via outcome control. Biomechanically meaningful diagnostic x-rays of the spinal segment to be surgically treated are currently carried out with the patient in inclination and reclination. Software-related preoperative simulation based on these x-ray images facilitates the selection and implementation of the MAST procedure. For preoperative simulation motion shots are needed in inclination, neutral position and reclination and the dimensions can be obtained using an x-ray ball or a computed tomography (CT) scan. The SENDS criteria are useful because established procedures based on these criteria reach a comparable outcome. Preoperative simulation appears to be a useful selection criterion. Preoperatively it is necessary to collate patient and segment information in order to provide each patient with individualized treatment. So far there is no evidence for a better outcome after preoperative simulation but a reduction of surgery time and intraoperative radiation exposure could already be demonstrated. Minimally invasive methods should be preferred if there is a comparable outcome. The establishment of new procedures has to be accompanied by the maintenance of a spine register. Minimally invasive surgical procedures should be individualized for each patient and segment. Mobility X-ray images should be prepared for use with the preoperative simulation as the information content significantly increases with respect to the MAST procedure. (orig.) [de

  11. Torsion of the greater omentum: A rare preoperative diagnosis

    International Nuclear Information System (INIS)

    Tandon, Ankit Anil; Lim, Kian Soon

    2010-01-01

    Torsion of the greater omentum is a rare acute abdominal condition that is seldom diagnosed preoperatively. We report the characteristic computed tomography (CT) scan findings and the clinical implications of this unusual diagnosis in a 41-year-old man, who also had longstanding right inguinal hernia. Awareness of omental torsion as a differential diagnosis in the acute abdomen setting is necessary for correct patient management

  12. Predictors of Persistent Axial Neck Pain After Cervical Laminoplasty.

    Science.gov (United States)

    Kimura, Atsushi; Shiraishi, Yasuyuki; Inoue, Hirokazu; Endo, Teruaki; Takeshita, Katsushi

    2018-01-01

    Retrospective analysis of prospective data. The aim of this study was to reveal baseline predictors of persistent postlaminoplasty neck pain. Axial neck pain is one of the most common complications after cervical laminoplasty; however, baseline predictors of persistent postlaminoplasty neck pain are unclear. We analyzed data from 156 patients who completed a 2-year follow-up after double-door laminoplasty for degenerative cervical myelopathy. Patients rated the average intensity of axial neck pain in the last month using an 11-point numerical rating scale preoperatively and at the 2-year follow-up. The dependent variable was the presence of moderate-to-severe neck pain (numerical rating scale ≥4) at the 2-year follow-up. The independent variables included patient characteristics, baseline radiological parameters, surgical variables, baseline axial neck pain intensity, and baseline functions, which were measured by the Japanese Orthopaedic Association score and the Short Form-36 survey (SF-36). Logistic regression analysis was performed to identify independent predictors of moderate-to-severe neck pain after laminoplasty. At the 2-year follow-up, 51 patients (32%) had moderate-to-severe neck pain, and 106 patients (68%) had no or mild pain. Univariate analysis revealed that the ratio of cervical anterolisthesis, ratio of current smoking, baseline neck pain intensity, and baseline SF-36 Mental Component Summary differed significantly between the groups. Multivariate logistic regression analysis showed that independent predictors of moderate-to-severe neck pain at the 2-year follow-up include the presence of anterolisthesis, current smoking, moderate-to-severe baseline neck pain, and lower SF-36 Mental Component Summary. The presence of anterolisthesis and moderate-to-severe baseline neck pain were also associated with significantly poorer physical function after surgery. The presence of anterolisthesis was associated not only with the highest odds ratio of

  13. Preoperative measurement of canine primary bone tumors, using radiography and bone scintigraphy

    International Nuclear Information System (INIS)

    Lamb, C.R.; Berg, J.; Bengston, A.E.

    1990-01-01

    Specimens of 20 canine primary bone tumors (18 osteosarcoma, 2 fibrosarcoma) were examined to compare the maximal axial length of gross tumor with the length of the lesion seen on preoperative radiographs and 99mTc methylene diphosphonate bone scintigraphic images. Radiographs defined the length of the tumor to within +/- 10% of the gross measurement for 6 (30%), underestimated it for 12 (60%), and overestimated it for 2 (10%) specimens. Bone scintigraphy defined tumor length within +/- 10% for 8 (40%), underestimated it for 1 (5%), and overestimated it for the remaining 11 (55%) specimens. Use of radiographic evaluation alone could result in underestimation of the diaphyseal extent of a primary bone tumor, with risk of incomplete resection. Bone scan images tend to overestimate tumor length and, therefore, may provide safer resection guidelines

  14. Gastric cancer: texture analysis from multidetector computed tomography as a potential preoperative prognostic biomarker

    Energy Technology Data Exchange (ETDEWEB)

    Giganti, Francesco; Salerno, Annalaura; Marra, Paolo; Esposito, Antonio; Del Maschio, Alessandro; De Cobelli, Francesco [Department of Radiology and Centre for Experimental Imaging San Raffaele Scientific Institute, Milan (Italy); San Raffaele Vita-Salute University, Milan (Italy); Antunes, Sofia [San Raffaele Scientific Institute, Centre for Experimental Imaging, Milan (Italy); Ambrosi, Alessandro [San Raffaele Vita-Salute University, Milan (Italy); Nicoletti, Roberto [Department of Radiology and Centre for Experimental Imaging San Raffaele Scientific Institute, Milan (Italy); Orsenigo, Elena [San Raffaele Scientific Institute, Department of Surgery, Milan (Italy); Chiari, Damiano; Staudacher, Carlo [San Raffaele Vita-Salute University, Milan (Italy); San Raffaele Scientific Institute, Department of Surgery, Milan (Italy); Albarello, Luca [San Raffaele Scientific Institute, Pathology Unit, Milan (Italy)

    2017-05-15

    To investigate the association between preoperative texture analysis from multidetector computed tomography (MDCT) and overall survival in patients with gastric cancer. Institutional review board approval and informed consent were obtained. Fifty-six patients with biopsy-proved gastric cancer were examined by MDCT and treated with surgery. Image features from texture analysis were quantified, with and without filters for fine to coarse textures. The association with survival time was assessed using Kaplan-Meier and Cox analysis. The following parameters were significantly associated with a negative prognosis, according to different thresholds: energy [no filter] - Logarithm of relative risk (Log RR): 3.25; p = 0.046; entropy [no filter] (Log RR: 5.96; p = 0.002); entropy [filter 1.5] (Log RR: 3.54; p = 0.027); maximum Hounsfield unit value [filter 1.5] (Log RR: 3.44; p = 0.027); skewness [filter 2] (Log RR: 5.83; p = 0.004); root mean square [filter 1] (Log RR: - 2.66; p = 0.024) and mean absolute deviation [filter 2] (Log RR: - 4.22; p = 0.007). Texture analysis could increase the performance of a multivariate prognostic model for risk stratification in gastric cancer. Further evaluations are warranted to clarify the clinical role of texture analysis from MDCT. (orig.)

  15. Correction of axial deformity during lengthening in fibular hypoplasia: Hexapodal versus monorail external fixation.

    Science.gov (United States)

    Chalopin, A; Geffroy, L; Pesenti, S; Hamel, A; Launay, F

    2017-09-01

    Childhood fibular hypoplasia is a rare pathology which may or may not involve limb-length discrepancy and axial deformity in one or more dimensions. The objective of the present study was to compare the quality of the axial correction achieved in lengthening procedures by hexapodal versus monorail external fixators. The hypothesis was that the hexapodal fixator provides more precise correction. A retrospective multicenter study included 52 children with fibular hypoplasia. Seventy-two tibias were analyzed, in 2 groups: 52 using a hexapodal fixator, and 20 using a monorail fixator. Mean age was 10.2 years. Mean lengthening was 5.7cm. Deformities were analyzed and measured in 3 dimensions and classified in 4 preoperative types and 4 post-lengthening types according to residual deformity. Complete correction was achieved in 26 tibias in the hexapodal group (50%) and 2 tibias in the monorail group (10%). Mean post-correction mechanical axis deviation was smaller in the hexapodal group: 12.83mm, versus 14.29mm in the monorail group. Mean post-correction mechanical lateral distal femoral angle was 87.5° in the hexapodal group, versus 84.3° in the monorail group (P=0.002), and mean mechanical medial proximal tibial angle 86.9° versus 89.5°, respectively (P=0.015). No previous studies focused on this congenital pathology in lengthening and axial correction programs for childhood lower-limb deformity. The present study found the hexapodal fixator to be more effective in conserving or restoring mechanical axes during progressive bone lengthening for fibular hypoplasia. The hexapodal fixator met the requirements of limb-length equalization in childhood congenital lower-limb hypoplasia, providing better axial correction than the monorail fixator. IV. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  16. Assessment of the impact of modeling axial compression on PET image reconstruction.

    Science.gov (United States)

    Belzunce, Martin A; Reader, Andrew J

    2017-10-01

    To comprehensively evaluate both the acceleration and image-quality impacts of axial compression and its degree of modeling in fully 3D PET image reconstruction. Despite being used since the very dawn of 3D PET reconstruction, there are still no extensive studies on the impact of axial compression and its degree of modeling during reconstruction on the end-point reconstructed image quality. In this work, an evaluation of the impact of axial compression on the image quality is performed by extensively simulating data with span values from 1 to 121. In addition, two methods for modeling the axial compression in the reconstruction were evaluated. The first method models the axial compression in the system matrix, while the second method uses an unmatched projector/backprojector, where the axial compression is modeled only in the forward projector. The different system matrices were analyzed by computing their singular values and the point response functions for small subregions of the FOV. The two methods were evaluated with simulated and real data for the Biograph mMR scanner. For the simulated data, the axial compression with span values lower than 7 did not show a decrease in the contrast of the reconstructed images. For span 11, the standard sinogram size of the mMR scanner, losses of contrast in the range of 5-10 percentage points were observed when measured for a hot lesion. For higher span values, the spatial resolution was degraded considerably. However, impressively, for all span values of 21 and lower, modeling the axial compression in the system matrix compensated for the spatial resolution degradation and obtained similar contrast values as the span 1 reconstructions. Such approaches have the same processing times as span 1 reconstructions, but they permit significant reduction in storage requirements for the fully 3D sinograms. For higher span values, the system has a large condition number and it is therefore difficult to recover accurately the higher

  17. Axial skeletal CT densitometry

    International Nuclear Information System (INIS)

    Lampmann, L.E.H.

    1982-01-01

    Since the discovery of the Roentgen ray a precise and accurate assessment of bone mineral content has been a challenge to many investigators. A number of methods have been developed but no one satisfied. Considering its technical possibilities computed tomography is very promising in determination of bone mineral content (BMC). The new modality enables BMC estimations in the axial skeletal trabecular bone. CT densitometry can be performed on a normal commercially available third generation whole body CT scanner. No dedicated device in a special clinical set-up is necessary. In this study 106 patients, most of them clinically suspected of osteoporosis, were examined. The new method CT densitometry has been evaluated. The results have been correlated to alternative BMC determination methods. (Auth.)

  18. Computerised Axial Tomography (CAT)

    Science.gov (United States)

    1990-06-01

    Ministry of’ Defence, Defence Research Information Centre, UK. Computerised Axial Tomography ( CAT ) Report Secufty C"uMiauion tide Onadtiicadon (U. R, Cor S...DRIC T 8485 COMPUTERISED AXIAL TOMOGRAPHY ( CAT ) F.P. GENTILE, F. SABETTA, V. TRO1* ISS R 78/4.Rome, 1.5 Mlarch 1978 (from Italian) B Distribution(f...dello Radiazioni ISSN 0390--6477 F.P. GENTILE, F. SABETTA. V. TROI Computerised Axial Tomography ( CAT ) March 15, 1978). This paper is a review of

  19. Role of fine needle aspiration cytology in the preoperative investigation of branchial cysts.

    Science.gov (United States)

    Slater, Jacqueline; Serpell, Jonathan W; Woodruff, Stacey; Grodski, Simon

    2012-01-01

    Successful preoperative diagnosis of a branchial cyst requires a systematic approach. The aim of this study was to evaluate methods of investigation of a lateral neck swelling suspicious for a branchial cyst, and to highlight cases where a less benign cause for the swelling should be suspected and therefore management altered appropriately. A retrospective case study of 24 patients with presumed branchial cysts managed operatively was undertaken. Demographic, clinical, imaging, cytology and histopathological data were analysed to formulate an approach to the work-up of a lateral neck swelling suspected to be a branchial cyst. All 24 patients presented with a lateral neck mass thought to be a branchial cyst preoperatively underwent preoperative fine-needle aspiration cytology. The overall accuracy of cytology in predicting a benign branchial cyst histopathologically was 83.3% (20 out of 24). Successful preoperative diagnosis of a branchial cyst requires a combination of imaging and cytology. If there is concern that a lateral neck swelling is not a branchial cyst on clinical, imaging or cytological features, then a full preoperative work-up, including computed tomography scan of the neck and upper aero-digestive tract endoscopy should be performed, prior to an excisional biopsy. © 2011 The Authors. ANZ Journal of Surgery © 2011 Royal Australasian College of Surgeons.

  20. Preoperative Chemotherapy Versus Preoperative Chemoradiotherapy for Stage III (N2) Non-Small-Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Higgins, Kristin [Department of Radiation Oncology, Duke University of Medical Center, Durham, NC (United States); Chino, Junzo P [Department of Radiation Oncology, Duke University of Medical Center, Durham, NC (United States); Marks, Lawrence B [Department of Radiation Oncology, University of North Carolina, Chapel Hill, NC (United States); Ready, Neal [Department of Medicine, Division of Medical Oncology, Duke University of Medical Center, Durham, NC (United States); D' Amico, Thomas A [Department of Surgery, Division of Cardiovascular and Thoracic Surgery, Duke University of Medical Center, Durham, NC (United States); Clough, Robert W; Kelsey, Chris R [Department of Radiation Oncology, Duke University of Medical Center, Durham, NC (United States)

    2009-12-01

    Purpose: To compare preoperative chemotherapy (ChT) and preoperative chemoradiotherapy (ChT-RT) in operable Stage III non-small-cell lung cancer. Methods and Materials: This retrospective study analyzed all patients with pathologically confirmed Stage III (N2) non-small-cell lung cancer who initiated preoperative ChT or ChT-RT at Duke University between 1995 and 2006. Mediastinal pathologic complete response (pCR) rates were compared using a chi-square test. The actuarial overall survival, disease-free survival, and local control were estimated using the Kaplan-Meier method and compared using the log-rank test. Multivariate Cox regression analysis was also performed. Results: A total of 101 patients who initiated preoperative therapy with planned resection were identified. The median follow-up was 20 months for all patients and 38 months for survivors. The mediastinal lymph nodes were reassessed after preoperative therapy in 88 patients (87%). Within this group, a mediastinal pCR was achieved in 35% after preoperative ChT vs. 65% after preoperative ChT-RT (p = 0.01). Resection was performed in 69% after ChT and 84% after ChT-RT (p = 0.1). For all patients, the overall survival, disease-free survival, and local control rate at 3 years was 40%, 27%, and 66%, respectively. No statistically significant differences were found in the clinical endpoints between the ChT and ChT-RT subgroups. On multivariate analysis, a mediastinal pCR was associated with improved disease-free survival (p = 0.03) and local control (p = 0.03), but not overall survival (p = 0.86). Conclusion: Preoperative ChT-RT was associated with higher mediastinal pCR rates but not improved survival.

  1. Preoperative Chemotherapy Versus Preoperative Chemoradiotherapy for Stage III (N2) Non-Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Higgins, Kristin; Chino, Junzo P.; Marks, Lawrence B.; Ready, Neal; D'Amico, Thomas A.; Clough, Robert W.; Kelsey, Chris R.

    2009-01-01

    Purpose: To compare preoperative chemotherapy (ChT) and preoperative chemoradiotherapy (ChT-RT) in operable Stage III non-small-cell lung cancer. Methods and Materials: This retrospective study analyzed all patients with pathologically confirmed Stage III (N2) non-small-cell lung cancer who initiated preoperative ChT or ChT-RT at Duke University between 1995 and 2006. Mediastinal pathologic complete response (pCR) rates were compared using a chi-square test. The actuarial overall survival, disease-free survival, and local control were estimated using the Kaplan-Meier method and compared using the log-rank test. Multivariate Cox regression analysis was also performed. Results: A total of 101 patients who initiated preoperative therapy with planned resection were identified. The median follow-up was 20 months for all patients and 38 months for survivors. The mediastinal lymph nodes were reassessed after preoperative therapy in 88 patients (87%). Within this group, a mediastinal pCR was achieved in 35% after preoperative ChT vs. 65% after preoperative ChT-RT (p = 0.01). Resection was performed in 69% after ChT and 84% after ChT-RT (p = 0.1). For all patients, the overall survival, disease-free survival, and local control rate at 3 years was 40%, 27%, and 66%, respectively. No statistically significant differences were found in the clinical endpoints between the ChT and ChT-RT subgroups. On multivariate analysis, a mediastinal pCR was associated with improved disease-free survival (p = 0.03) and local control (p = 0.03), but not overall survival (p = 0.86). Conclusion: Preoperative ChT-RT was associated with higher mediastinal pCR rates but not improved survival.

  2. Potentials of high resolution magnetic resonance imaging versus computed tomography for preoperative local staging of colon cancer

    International Nuclear Information System (INIS)

    Rollven, Erik; Blomqvist, Lennart; Holm, Torbjorn; Glimelius, Bengt; Loerinc, Esther

    2013-01-01

    Background: Preoperative identification of locally advanced colon cancer is of importance in order to properly plan treatment. Purpose: To study high resolution T2-weighted magnetic resonance imaging (MRI) versus computed tomography (CT) for preoperative staging of colon cancer with surgery and histopathology as reference standard. Material and Methods: Twenty-eight patients with a total of 29 tumors were included. Patients were examined on a 1.5 T MR unit using a phased array body coil. T2 turbo spin-echo high resolution sequences were obtained in a coronal, transverse, and perpendicular plane to the long axis of the colon at the site of the tumor. Contrast-enhanced CT was performed using a protocol for metastasis staging. The examinations were independently evaluated by two gastrointestinal radiologists using criteria adapted to imaging for prediction of T-stage, N-stage, and extramural venous invasion. Based on the T-stage, tumors were divided in to locally advanced (T3cd-T4) and not locally advanced (T1-T3ab). Surgical and histopathological findings served as reference standard. Results: Using MRI, T-stage, N-stage, and extramural venous invasion were correctly predicted for each observer in 90% and 93%, 72% and 69%, and 82% and 78% of cases, respectively. With CT the corresponding results were 79% and 76%, 72% and 72%, 78% and 67%. For MRI inter-observer agreements (Kappa statistics) were 0.79, 0.10, and 0.76. For CT the corresponding results were 0.64, 0.66, and 0.22. Conclusion: Patients with locally advanced colon cancer, defined as tumor stage T3cd-T4, can be identified by both high resolution MRI and CT, even when CT is performed with a metastasis staging protocol. MRI may have an advantage, due to its high soft tissue discrimination, to identify certain prognostic factors such as T-stage and extramural venous invasion

  3. Potentials of high resolution magnetic resonance imaging versus computed tomography for preoperative local staging of colon cancer

    Energy Technology Data Exchange (ETDEWEB)

    Rollven, Erik; Blomqvist, Lennart [Dept. of Diagnostic Radiology, Karolinska Univ. Hospital Solna, Stockholm (Sweden); Dept. of Molecular Medicine and Surgery, Karolinska Inst., Stockholm (Sweden)], e-mail: erik.rollven@ki.se; Holm, Torbjorn [Dept. of Molecular Medicine and Surgery, Karolinska Inst., Stockholm (Sweden); Dept. of Surgery, Karolinska Univ. Hospital Solna, Stockholm (Sweden); Glimelius, Bengt [Dept. of Radiology, Oncology and Radiation Science, Uppsala Univ., Uppsala (Sweden); Dept. of Oncology and Pathology, Karolinska Inst., Stockholm (Sweden); Loerinc, Esther [Dept. of Oncology and Pathology, Karolinska Inst., Stockholm (Sweden); Dept. of Pathology, Karolinska Univ. Hospital, Solna, Sweden (Sweden)

    2013-09-15

    Background: Preoperative identification of locally advanced colon cancer is of importance in order to properly plan treatment. Purpose: To study high resolution T2-weighted magnetic resonance imaging (MRI) versus computed tomography (CT) for preoperative staging of colon cancer with surgery and histopathology as reference standard. Material and Methods: Twenty-eight patients with a total of 29 tumors were included. Patients were examined on a 1.5 T MR unit using a phased array body coil. T2 turbo spin-echo high resolution sequences were obtained in a coronal, transverse, and perpendicular plane to the long axis of the colon at the site of the tumor. Contrast-enhanced CT was performed using a protocol for metastasis staging. The examinations were independently evaluated by two gastrointestinal radiologists using criteria adapted to imaging for prediction of T-stage, N-stage, and extramural venous invasion. Based on the T-stage, tumors were divided in to locally advanced (T3cd-T4) and not locally advanced (T1-T3ab). Surgical and histopathological findings served as reference standard. Results: Using MRI, T-stage, N-stage, and extramural venous invasion were correctly predicted for each observer in 90% and 93%, 72% and 69%, and 82% and 78% of cases, respectively. With CT the corresponding results were 79% and 76%, 72% and 72%, 78% and 67%. For MRI inter-observer agreements (Kappa statistics) were 0.79, 0.10, and 0.76. For CT the corresponding results were 0.64, 0.66, and 0.22. Conclusion: Patients with locally advanced colon cancer, defined as tumor stage T3cd-T4, can be identified by both high resolution MRI and CT, even when CT is performed with a metastasis staging protocol. MRI may have an advantage, due to its high soft tissue discrimination, to identify certain prognostic factors such as T-stage and extramural venous invasion.

  4. Thermal characterization of phacoemulsification probes operated in axial and torsional modes.

    Science.gov (United States)

    Zacharias, Jaime

    2015-01-01

    To analyze temperature increases and identify potential sources of heat generated when sleeved and sleeveless phacoemulsification probes were operated in axial and torsional modes using the Infiniti Vision System with the Ozil torsional handpiece. Phacodynamics Laboratory, Pasteur Ophthalmic Clinic, Santiago, Chile. Experimental study. Two computer-controlled thermal transfer systems were developed to evaluate the contribution of internal metal stress and tip-to-sleeve friction on heat generation during phacoemulsification using axial and torsional ultrasound modalities. Both systems incorporated infrared thermal imaging and used a black-body film to accurately capture temperature measurements. Axial mode was consistently associated with greater temperature increases than torsional mode whether tips were operated with or without sleeves. In tests involving bare tips, axial mode and torsional mode peaked at 51.7°C and 34.2°C, respectively. In an example using sleeved tips in which a 30.0 g load was applied for 1 second, temperatures for axial mode reached 45°C and for torsional mode, 38°C. Friction between the sleeved probe and the incisional wall contributed more significantly to the temperature increase than internal metal stress regardless of the mode used. In all experiments, the temperature increase observed with axial mode was greater than that observed with torsional mode, even when conditions such as power or amplitude and flow rate were varied. Tip-to-sleeve friction was a more dominant source of phaco probe heating than internal metal stress. The temperature increase due to internal metal stress was greater with axial mode than with torsional mode. Dr. Zacharias received research funding from Alcon Laboratories, Inc., to conduct this study. He has no financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  5. Utility of Electrocardiography (ECG)-Gated Computed Tomography (CT) for Preoperative Evaluations of Thymic Epithelial Tumors.

    Science.gov (United States)

    Ozawa, Yoshiyuki; Hara, Masaki; Nakagawa, Motoo; Shibamoto, Yuta

    2016-01-01

    Preoperative evaluation of invasion to the adjacent organs is important for the thymic epithelial tumors on CT. The purpose of our study was to evaluate the utility of electrocardiography (ECG)-gated CT for assessing thymic epithelial tumors with regard to the motion artifacts produced and the preoperative diagnostic accuracy of the technique. Forty thymic epithelial tumors (36 thymomas and 4 thymic carcinomas) were examined with ECG-gated contrast-enhanced CT using a dual source scanner. The scan delay after the contrast media injection was 30 s for the non-ECG-gated CT and 100 s for the ECG-gated CT. Two radiologists blindly evaluated both the non-ECG-gated and ECG-gated CT images for motion artifacts and determined whether the tumors had invaded adjacent structures (mediastinal fat, superior vena cava, brachiocephalic veins, aorta, pulmonary artery, pericardium, or lungs) on each image. Motion artifacts were evaluated using a 3-grade scale. Surgical and pathological findings were used as a reference standard for tumor invasion. Motion artifacts were significantly reduced for all structures by ECG gating ( p =0.0089 for the lungs and p ECG-gated CT and ECG-gated CT demonstrated 79% and 95% accuracy, respectively, during assessments of pericardial invasion ( p =0.03). ECG-gated CT reduced the severity of motion artifacts and might be useful for preoperative assessment whether thymic epithelial tumors have invaded adjacent structures.

  6. Preoperative alcoholism and postoperative morbidity

    DEFF Research Database (Denmark)

    Tonnesen, H; Kehlet, H

    1999-01-01

    BACKGROUND: Preoperative risk assessment has become part of daily clinical practice, but preoperative alcohol abuse has not received much attention. METHODS: A Medline search was carried out to identify original papers published from 1967 to 1998. Relevant articles on postoperative morbidity...... in alcohol abusers were used to evaluate the evidence. RESULTS: Prospective and retrospective studies demonstrate a twofold to threefold increase in postoperative morbidity in alcohol abusers, the most frequent complications being infections, bleeding and cardiopulmonary insufficiency. Wound complications...... to postoperative morbidity. CONCLUSION: Alcohol consumption should be included in the preoperative assessment of likely postoperative outcome. Reduction of postoperative morbidity in alcohol abusers may include preoperative alcohol abstinence to improve organ function, or perioperative alcohol administration...

  7. Preoperative Diagnosis of Adult Intussusception Caused by Small Bowel Lipoma

    Directory of Open Access Journals (Sweden)

    Hiroaki Shiba

    2009-11-01

    Full Text Available Adult intussusception is rare, accounting for only 5% of all intussusceptions, for which preoperative diagnosis is difficult. We herein report a preoperatively diagnosed case of adult intussusception caused by a small bowel lipoma. A 33-year-old man was admitted to our hospital with three weeks history of colicky epigastric pain. Computed tomography revealed thickening of the ileal wall suggestive of intussusception. Colonoscopy revealed an ileocolic intussusception. Barium enema for reduction of ileocolic intussusception demonstrated a small bowel tumor in the ileum 15 cm proximal to the ileocecal valve. The intussusception was reduced, and the patient underwent partial resection of the ileum encompassing the small bowel tumor. Histological findings confirmed the diagnosis of lipoma of the small bowel. The patient made a satisfactory recovery and remains well.

  8. Three Dimensional Viscous Flow Field in an Axial Flow Turbine Nozzle Passage

    Science.gov (United States)

    Ristic, D.; Lakshminarayana, B.

    1997-01-01

    The objective of this investigation is experimental and computational study of three dimensional viscous flow field in the nozzle passage of an axial flow turbine stage. The nozzle passage flow field has been measured using a two sensor hot-wire probe at various axial and radial stations. In addition, two component LDV measurements at one axial station (x/c(sum m) = 0.56) were performed to measure the velocity field. Static pressure measurements and flow visualization, using a fluorescent oil technique, were also performed to obtain the location of transition and the endwall limiting streamlines. A three dimensional boundary layer code, with a simple intermittency transition model, was used to predict the viscous layers along the blade and endwall surfaces. The boundary layers on the blade surface were found to be very thin and mostly laminar, except on the suction surface downstream of 70% axial chord. Strong radial pressure gradient, especially close to the suction surface, induces strong cross flow components in the trailing edge regions of the blade. On the end-walls the boundary layers were much thicker, especially near the suction corner of the casing surface, caused by secondary flow. The secondary flow region near the suction-casing surface corner indicates the presence of the passage vortex detached from the blade surface. The corner vortex is found to be very weak. The presence of a closely spaced rotor downstream (20% of the nozzle vane chord) introduces unsteadiness in the blade passage. The measured instantaneous velocity signal was filtered using FFT square window to remove the periodic unsteadiness introduced by the downstream rotor and fans. The filtering decreased the free stream turbulence level from 2.1% to 0.9% but had no influence on the computed turbulence length scale. The computation of the three dimensional boundary layers is found to be accurate on the nozzle passage blade surfaces, away from the end-walls and the secondary flow region. On

  9. Three-dimensional computed tomography in the assessment of congenital scoliosis

    International Nuclear Information System (INIS)

    Bush, C.H.; Kalen, V.

    1999-01-01

    Objective. Patients with congenital vertebral anomalies frequently are afflicted with kyphoscoliosis, with the curvatures often being severe and progressive. Spinal fusion almost always is the treatment of choice in such patients. This report examines the use of three-dimensional computed tomography (3D CT) in the preoperative investigation of patients with congenital scoliosis.Design and patients. Twelve spinal CT examinations on 11 pediatric patients with congenital scoliosis underwent image processing to produce 3D images. The 3D images were compared with both the axial sections from the CT examinations and multiplanar reformations with regard to the detection of malformations liable to cause progression of scoliosis (i. e., hemivertebrae and unsegmented bars).Results and conclusions. In six of the 12 cases, the 3D images provided improved depiction of the congenital anomalies and their interrelationships compared with planar CT images. This work suggests that 3D CT can be a useful tool in the assessment of patients with congenital scoliosis. (orig.)

  10. Resolution of axial shear strain elastography

    International Nuclear Information System (INIS)

    Thitaikumar, Arun; Righetti, Raffaella; Krouskop, Thomas A; Ophir, Jonathan

    2006-01-01

    The technique of mapping the local axial component of the shear strain due to quasi-static axial compression is defined as axial shear strain elastography. In this paper, the spatial resolution of axial shear strain elastography is investigated through simulations, using an elastically stiff cylindrical lesion embedded in a homogeneously softer background. Resolution was defined as the smallest size of the inclusion for which the strain value at the inclusion/background interface was greater than the average of the axial shear strain values at the interface and inside the inclusion. The resolution was measured from the axial shear strain profile oriented at 45 0 to the axis of beam propagation, due to the absence of axial shear strain along the normal directions. The effects of the ultrasound system parameters such as bandwidth, beamwidth and transducer element pitch along with signal processing parameters such as correlation window length (W) and axial shift (ΔW) on the estimated resolution were investigated. The results show that the resolution (at 45 0 orientation) is determined by the bandwidth and the beamwidth. However, the upper bound on the resolution is limited by the larger of the beamwidth and the window length, which is scaled inversely to the bandwidth. The results also show that the resolution is proportional to the pitch and not significantly affected by the axial window shift

  11. Role of preoperative 3-dimensional computed tomography reconstruction in depressed skull fractures treated with craniectomy: a case report of forensic interest.

    Science.gov (United States)

    Viel, Guido; Cecchetto, Giovanni; Manara, Renzo; Cecchetto, Attilio; Montisci, Massimo

    2011-06-01

    Patients affected by cranial trauma with depressed skull fractures and increased intracranial pressure generally undergo neurosurgical intervention. Because craniotomy and craniectomy remove skull fragments and generate new fracture lines, they complicate forensic examination and sometimes prevent a clear identification of skull fracture etiology. A 3-dimensional reconstruction based on preoperative computed tomography (CT) scans, giving a picture of the injuries before surgical intervention, can help the forensic examiner in identifying skull fracture origin and the means of production.We report the case of a 41-year-old-man presenting at the emergency department with a depressed skull fracture at the vertex and bilateral subdural hemorrhage. The patient underwent 2 neurosurgical interventions (craniotomy and craniectomy) but died after 40 days of hospitalization in an intensive care unit. At autopsy, the absence of various bone fragments did not allow us to establish if the skull had been stricken by a blunt object or had hit the ground with high kinetic energy. To analyze bone injuries before craniectomy, a 3-dimensional CT reconstruction based on preoperative scans was performed. A comparative analysis between autoptic and radiological data allowed us to differentiate surgical from traumatic injuries. Moreover, based on the shape and size of the depressed skull fracture (measured from the CT reformations), we inferred that the man had been stricken by a cylindric blunt object with a diameter of about 3 cm.

  12. Computer Learning Through Piaget's Eyes.

    Science.gov (United States)

    Huber, Leonard N.

    1985-01-01

    Discusses Piaget's pre-operational, concrete operational, and formal operational stages and shows how this information sheds light on how children approach computers and computing, particularly with the LOGO programming language. (JN)

  13. Estimation Methods of the Point Spread Function Axial Position: A Comparative Computational Study

    Directory of Open Access Journals (Sweden)

    Javier Eduardo Diaz Zamboni

    2017-01-01

    Full Text Available The precise knowledge of the point spread function is central for any imaging system characterization. In fluorescence microscopy, point spread function (PSF determination has become a common and obligatory task for each new experimental device, mainly due to its strong dependence on acquisition conditions. During the last decade, algorithms have been developed for the precise calculation of the PSF, which fit model parameters that describe image formation on the microscope to experimental data. In order to contribute to this subject, a comparative study of three parameter estimation methods is reported, namely: I-divergence minimization (MIDIV, maximum likelihood (ML and non-linear least square (LSQR. They were applied to the estimation of the point source position on the optical axis, using a physical model. Methods’ performance was evaluated under different conditions and noise levels using synthetic images and considering success percentage, iteration number, computation time, accuracy and precision. The main results showed that the axial position estimation requires a high SNR to achieve an acceptable success level and higher still to be close to the estimation error lower bound. ML achieved a higher success percentage at lower SNR compared to MIDIV and LSQR with an intrinsic noise source. Only the ML and MIDIV methods achieved the error lower bound, but only with data belonging to the optical axis and high SNR. Extrinsic noise sources worsened the success percentage, but no difference was found between noise sources for the same method for all methods studied.

  14. Signatures for axial chromodynamics

    International Nuclear Information System (INIS)

    Pati, J.C.

    1978-07-01

    Within the context of basic left-right symmetry and the hypothesis of unification of weak, electromagnetic and strong forces at a mass level approximately equal to 10 4 -10 6 GeV, relatively light ''mass'' axial gluons, confined or liberated, must be postulated. The authors remark that the existence of such ''light'' axial gluons supplementing the familiar vector octet preserves the successes of QCD, both for deep inelastic processes and charmonium physics. Through the characteristic spin-spin force, generated by their exchange, they may even help resolve some of the discrepancies between vector QCD predictions and charmonium physics. The main remark of this note is that if colour is liberated, not only vector but also axial-vector gluons are produced in high-energy e - e + experiments, e.g. at PETRA and PEP, with fairly large cross-section. Distinctive decay modes of such liberated axial gluons are noted

  15. Tangential derivative mapping of axial MEG applied to event-related desynchronization research

    NARCIS (Netherlands)

    Bastiaansen, M.C.M.; Knösche, T.R.

    2000-01-01

    Objectives: A problem with the topographic mapping of MEG data recorded with axial gradiometers is that field extrema are measured at sensors located at either side of a neuronal generator instead of at sensors directly above the source. This is problematic for the computation of event-related

  16. Deformation and collapse of zircaloy fuel rod cladding into plenum axial gaps

    International Nuclear Information System (INIS)

    Pfennigwerth, P.L.; Gorscak, D.A.; Selsley, I.A.

    1983-01-01

    To minimize support structure, blanket and reflector fuel rods of the thoria urania-fueled Light Water Breeder Reactor (LWBR) were designed with non-freestanding Zircaloy-4 cladding. An analytical model was developed to predict deformation of unirradiated cladding into axial gaps of fuel rod plenum regions where it is unsupported. This model uses the ACCEPT finite element computer program to calculate elastic-plastic deformation of cladding due to external pressure. The finite element is 20-node, triquadratic, isoparametric, and 3-dimensional. Its curved surface permits accurate modeling of the tube geometry, including geometric nonuniformities such as circumferential wall thickness variation and initial tube out-of-roundness. Progressive increases in axial gap length due to cladding elongation and fuel stack shrinkage are modeled, as are deformations of fuel pellets and stainless steel support sleeves which bound plenum axial gaps in LWBR type blanket fuel rods. Zircaloy-4 primary and secondary thermal creep representations were developed from uniaxial creep testing of fuel rod tubing. Creep response to multi-axial loading is modeled with a variation of Hill's formulation for anisotropic materials. Coefficients accounting for anisotropic thermal creep in Zircaloy-4 tubes were developed from creep testing of externally pressurized tubes having fixed axial gaps in the range 2.5 cm to 5.7 cm and radial clearances over simulated fuel pellets ranging from zero to 0.089 mm. (orig./RW)

  17. Development of a 3-dimensional flow analysis procedure for axial pump impellers

    International Nuclear Information System (INIS)

    Kim, Min Hwan; Kim, Jong In; Park, Jin Seok; Huh, Houng Huh; Chang, Moon Hee

    1999-06-01

    A fluid dynamic analysis procedure was developed using the three-dimensional solid model of an axial pump impeller which was theoretically designed using I-DEAS CAD/CAM/CAE software. The CFD software FLUENT was used in the flow field analysis. The steady-state flow regime in the MCP impeller and diffuser was simulated using the developed procedure. The results of calculation were analyzed to confirm whether the design requirements were properly implemented in the impeller model. The validity of the developed procedure was demonstrated by comparing the calculation results with the experimental data available. The pump performance at the design point could be effectively predicted using the developed procedure. The computed velocity distributions have shown a good agreement with the experimental data except for the regions near the wall. The computed head, however, was over-predicted than the experiment. The design period and cost required for the development of an axial pump impeller can be significantly reduced by applying the proposed methodology. (author). 7 refs., 2 tabs

  18. Preoperative atrial fibrillation and long-term survival after open heart surgery in a rural tertiary heart institute.

    Science.gov (United States)

    O'Neal, Wesley T; Efird, Jimmy T; Davies, Stephen W; Choi, Yuk Ming; Anderson, Curtis A; Kindell, Linda C; O'Neal, Jason B; Ferguson, T Bruce; Chitwood, W Randolph; Kypson, Alan P

    2013-01-01

    Preoperative atrial fibrillation (AF) is associated with increased morbidity and mortality after open heart surgery. However, the impact of preoperative AF on long-term survival after open heart surgery has not been widely examined in rural populations. Patients from rural regions are less likely to receive treatment for cardiac conditions and to have adequate medical insurance coverage. To examine the influence of preoperative AF on long-term survival following open heart surgery in rural eastern North Carolina. Long-term survival was compared in patients with and without preoperative AF after coronary artery bypass grafting (CABG) and CABG plus valve (CABG + V) surgery between 2002 and 2011. Hazard ratios (HR) and 95% confidence intervals (CI) were computed using a Cox regression model. The study population consisted of 5438 patients. A total of 263 (5%) patients had preoperative AF. Preoperative AF was an independent predictor of long-term survival (open heart surgery: adjusted HR = 1.6, 95% CI = 1.3-2.0; CABG: adjusted HR = 1.6, 95% CI = 1.3-2.1; CABG + V: adjusted HR = 1.6, 95% CI = 1.1-2.3). Preoperative AF is an important predictor of long-term survival after open heart surgery in this rural population. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. A new strategy of axial power distribution control based on three axial offsets concept

    International Nuclear Information System (INIS)

    Shimazu, Yoichiro

    2009-01-01

    We have proposed a very simple control procedure for axial xenon oscillation control based on a characteristic trajectory. The trajectory is drawn by three offsets of power distributions, namely, AOp, AOi and AOx. They are defined as the offset of axial power distribution, the offset of the power distribution under which the current iodine distribution is obtained as the equilibrium and that for xenon distribution, respectively. When these offsets are plotted on X-Y plane for (AOp-AOx, AOi-AOx) the trajectory draws a quite characteristic ellipse (or an elliptic spiral). On the other hands, Constant Axial Offset Control (CAOC) procedure is adopted as axial power distribution control strategy during both base load and load following operations in domestic PWRs. In the previous paper, we have presented an innovative procedure of axial power distribution control during load following in PWRs based on this trajectory such that the AOp-AOx is to be controlled to zero when the value deviates the pre-determined limiting values. In this paper we propose a modified control strategy to get more stability of axial power distributions. In this strategy, we control the trajectory to be close to the major axis of the ellipse when the power distribution reaches the limiting values. In other words, the plot is not controlled only to reduce AOp-AOx but also AOi-AOx is taken into account at the same time. It is known that when the plot is controlled to the major axis, it means that the point gives the peak position of axial xenon oscillation. Therefore xenon oscillation will not increase its amplitude any more. Thus more stable axial power distribution control is attained. This kind of design concept is quite important especially for the future PWRs with elongated fuel length and longer core life. Because in a longer effective core and also the longer core life, it has been known that the stability of axial xenon oscillation becomes more unstable. In this paper, some simulation

  20. Aerodynamic Modelling and Optimization of Axial Fans

    DEFF Research Database (Denmark)

    Sørensen, Dan Nørtoft

    A numerically efficient mathematical model for the aerodynamics oflow speed axial fans of the arbitrary vortex flow type has been developed.The model is based on a blade-element principle, whereby therotor is divided into a number of annular streamtubes.For each of these streamtubes relations......-Raphson method, andsolutions converged to machine accuracy are found at small computing costs.The model has been validated against published measurementson various fan configurations,comprising two rotor-only fan stages, a counter-rotatingfan unit and a stator-rotor-stator stage.Comparisons of local...... and integrated propertiesshow that the computed results agree well with the measurements.Integrating a rotor-only version of the aerodynamic modelwith an algorithm for numerical designoptimization, enables the finding of an optimum fan rotor.The angular velocity of the rotor, the hub radius and the spanwise...

  1. Modernity: A new axial (era culture?

    Directory of Open Access Journals (Sweden)

    Wolfgang Schluchter

    2017-10-01

    Full Text Available The proposition of an axial age, lasting roughly from 800 to 200 B.C. and occurring in major civilizations (China, India, Near East independent of each other, first introduced by Alfred Weber and Karl Jaspers, then further developed by Robert Bellah and S. N. Eisenstadt among others, implied from the outset the question whether there has been a second axial age, leading to modernity, and if so, whether this second axial age consists in a secularization of the achievements of the first axial age. In this article it is argued that the notion of a second axial age is meaningful, but that the emergence of modernity can›t be accounted for in terms of secularization of the achievements of the first axial age. Rather, a new axial principle was institutionalized which separates the modern from the premodern world. This new principle is spelled out with reference to Hans Blumenberg, Charles Taylor and especially Max Weber. The emphasis is on the dialectics of disenchantment and the place of religion in a secular age

  2. The reliability of identifying the Omega sign using axial T2-weighted magnetic resonance imaging.

    Science.gov (United States)

    Zakaria, Hesham Mostafa; Massa, Peter Joseph; Smith, Richard L; Moharram, Tarek Hazem; Corrigan, John; Lee, Ian; Schultz, Lonni; Hu, Jianhui; Patel, Suresh; Griffith, Brent

    2018-01-01

    Preoperative identification of the eloquent brain is important for neurosurgical planning. One common method of finding the motor cortex is by localizing "the Omega sign." No studies have tested the reliability of imaging to identify the Omega sign. We identified 40 recent and consecutive patients who had undergone preoperative functional magnetic resonance imaging for identification of the hand motor area prior to tumor resection. We recruited 11 neurosurgical residents of various levels of training and one board-certified neurosurgeon to identify the hand motor cortex Omega. Testees were given axial images of T2-weighted MRI and placed marks where they expected to find the Omega. Two board-certified radiologists graded and quantified the localization attempts. Inter-rater reliability was assessed using the kappa statistic, and Rao-Scott chi-square tests were used to examine the relationship between clinical factors and testees' experience with correct identification of the Omega sign. The overall correct identification rate was 69.9% (95% CI = 63.4-75.7), ranging from 36.6% to 92.7% among all raters for the tumor side and from 46.2% to 97.4% for the non-tumor side. Anatomic distortion greatly affected correct identification ( p Omega than junior residents ( p Omega sign is poor, with a Fleiss kappa of 0.23. We concluded that correct identification of the Omega sign is affected by tumor distortion and experience but overall is not reliable. This underscores the limitations of anatomic landmarks and the importance of utilizing multiple scanning planes and preoperative fMRI for appropriate localization.

  3. Comparing the Effectiveness of Sagittal Balance, Foraminal Stenosis, and Preoperative Cord Rotation in Predicting Postoperative C5 Palsy.

    Science.gov (United States)

    Chugh, Arunit J S; Weinberg, Douglas S; Alonso, Fernando; Eubanks, Jason D

    2017-11-01

    Retrospective cohort review. To determine whether preoperative cord rotation is independently correlated with C5 palsy when analyzed alongside measures of sagittal balance and foraminal stenosis. Postoperative C5 palsy is a well-documented complication of cervical procedures with a prevalence of 4%-8%. Recent studies have shown a correlation with preoperative spinal cord rotation. There have been few studies, however, that have examined the role of sagittal balance and foraminal stenosis in the development of C5 palsy. A total of 77 patients who underwent cervical decompression-10 of whom developed C5 palsy-were reviewed. Sagittal balance was assessed using curvature angle and curvature index on radiographs and magnetic resonance image (MRI). Cord rotation was assessed on axial MRI. C4-C5 foraminal stenosis was assessed on sagittal MRI using area measurements and a grading scale. Demographics and information on surgical approach were gathered from chart review. Correlation with C5 palsy was performed by point-biserial, χ, and regression analyses. Point-biserial analysis indicated that only cord rotation showed significance (Pbalance did not correlate with presence of C5 palsy. Logistic regression model yielded cord rotation as the only significant independent predictor of C5 palsy. For every degree of axial cord rotation, the likelihood ratio for suffering a C5 palsy was 3.93 (95% confidence interval, 2.01-8.66; Ppoints to mechanisms other than direct compression as the etiology. In addition, the lack of correlation with postoperative changes in sagittal balance hints that measures of curvature angle and curvature index may not be appropriate to accurately predict this complication. Level 3.

  4. An anaesthetic pre-operative assessment clinic reduces pre-operative inpatient stay in patients requiring major vascular surgery.

    LENUS (Irish Health Repository)

    O'Connor, D B

    2012-02-01

    BACKGROUND: Patients undergoing major vascular surgery (MVS) require extensive anaesthetic assessment. This can require extended pre-operative stays. AIMS: We investigated whether a newly established anaesthetic pre-operative assessment clinic (PAC) would reduce the pre-operative inpatient stay, avoid unnecessary investigations and facilitate day before surgery (DBS) admissions for patients undergoing MVS. PATIENT AND METHODS: One year following and preceding the establishment of the PAC the records of patients undergoing open or endovascular aortic aneurysm repair, carotid endarterectomy and infra-inguinal bypass were reviewed to measure pre-operative length of stay (LoS). RESULTS: Pre-operative LoS was significantly reduced in the study period (1.85 vs. 4.2 days, respectively, P < 0.0001). Only 12 out of 61 patients in 2007 were admitted on the DBS and this increased to 33 out of 63 patients (P = 0.0002). No procedure was cancelled for medical reasons. CONCLUSION: The PAC has facilitated accurate outpatient anaesthetic assessment for patients requiring MVS. The pre-operative in-patient stay has been significantly reduced.

  5. Weight-bearing computed tomography findings in varus ankle osteoarthritis: abnormal internal rotation of the talus in the axial plane.

    Science.gov (United States)

    Kim, Ji-Beom; Yi, Young; Kim, Jae-Young; Cho, Jae-Ho; Kwon, Min-Soo; Choi, Seung-Hyuk; Lee, Woo-Chun

    2017-08-01

    To assess the incidence of abnormal internal rotation of the talus in the axial plane in patients with varus ankle osteoarthritis, and to determine whether this incidence differs from the severity of varus ankle osteoarthritis (moderate versus severe). We retrospectively evaluated weight-bearing computed tomography (CT) and plain radiographs of 52 ankles with no abnormalities (control group) and 96 ankles with varus osteoarthritis (varus-OA group), which were further stratified into a moderate-OA subgroup (50 ankles) and a severe-OA subgroup (46 ankles). A new radiographic parameter on weight-bearing CT, the talus rotation ratio, was used to assess the rotation of the talus in the axial plane. The normal range of the talus rotation ratio was defined as the 95% prediction interval for talus rotation ratio values in the control group. Abnormal internal rotation of the talus was defined for talus rotation ratio values above the normal range. We determined the incidence of abnormal internal rotation of the talus in the varus-OA group, moderate-OA subgroup, and severe-OA subgroup. In the varus-OA group, the incidence of abnormal internal rotation of the talus was 45% (43 ankles), which corresponded to an incidence of 32% (16 ankles) in the moderate-OA subgroup and 59% (27 ankles) in the severe-OA subgroup (p = 0.013). Our study demonstrates that abnormal internal rotation of the talus occurs in patients with varus ankle osteoarthritis, and is more frequently noted in severe than in moderate varus ankle osteoarthritis.

  6. Weight-bearing computed tomography findings in varus ankle osteoarthritis: abnormal internal rotation of the talus in the axial plane

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji-Beom; Yi, Young; Lee, Woo-Chun [Seoul Foot and Ankle Center, Dubalo Orthopaedic Clinic, Seochogu, Seoul (Korea, Republic of); Kim, Jae-Young; Kwon, Min-Soo; Choi, Seung-Hyuk [Inje University Seoul Paik Hospital, Department of Orthopaedic Surgery, Jung-gu, Seoul (Korea, Republic of); Cho, Jae-Ho [Hallym University, ChunCheon Sacred Heart Hospital, Department of Orthopaedic Surgery, Chuncheon, GangWon-do (Korea, Republic of)

    2017-08-15

    To assess the incidence of abnormal internal rotation of the talus in the axial plane in patients with varus ankle osteoarthritis, and to determine whether this incidence differs from the severity of varus ankle osteoarthritis (moderate versus severe). We retrospectively evaluated weight-bearing computed tomography (CT) and plain radiographs of 52 ankles with no abnormalities (control group) and 96 ankles with varus osteoarthritis (varus-OA group), which were further stratified into a moderate-OA subgroup (50 ankles) and a severe-OA subgroup (46 ankles). A new radiographic parameter on weight-bearing CT, the talus rotation ratio, was used to assess the rotation of the talus in the axial plane. The normal range of the talus rotation ratio was defined as the 95% prediction interval for talus rotation ratio values in the control group. Abnormal internal rotation of the talus was defined for talus rotation ratio values above the normal range. We determined the incidence of abnormal internal rotation of the talus in the varus-OA group, moderate-OA subgroup, and severe-OA subgroup. In the varus-OA group, the incidence of abnormal internal rotation of the talus was 45% (43 ankles), which corresponded to an incidence of 32% (16 ankles) in the moderate-OA subgroup and 59% (27 ankles) in the severe-OA subgroup (p = 0.013). Our study demonstrates that abnormal internal rotation of the talus occurs in patients with varus ankle osteoarthritis, and is more frequently noted in severe than in moderate varus ankle osteoarthritis. (orig.)

  7. Weight-bearing computed tomography findings in varus ankle osteoarthritis: abnormal internal rotation of the talus in the axial plane

    International Nuclear Information System (INIS)

    Kim, Ji-Beom; Yi, Young; Lee, Woo-Chun; Kim, Jae-Young; Kwon, Min-Soo; Choi, Seung-Hyuk; Cho, Jae-Ho

    2017-01-01

    To assess the incidence of abnormal internal rotation of the talus in the axial plane in patients with varus ankle osteoarthritis, and to determine whether this incidence differs from the severity of varus ankle osteoarthritis (moderate versus severe). We retrospectively evaluated weight-bearing computed tomography (CT) and plain radiographs of 52 ankles with no abnormalities (control group) and 96 ankles with varus osteoarthritis (varus-OA group), which were further stratified into a moderate-OA subgroup (50 ankles) and a severe-OA subgroup (46 ankles). A new radiographic parameter on weight-bearing CT, the talus rotation ratio, was used to assess the rotation of the talus in the axial plane. The normal range of the talus rotation ratio was defined as the 95% prediction interval for talus rotation ratio values in the control group. Abnormal internal rotation of the talus was defined for talus rotation ratio values above the normal range. We determined the incidence of abnormal internal rotation of the talus in the varus-OA group, moderate-OA subgroup, and severe-OA subgroup. In the varus-OA group, the incidence of abnormal internal rotation of the talus was 45% (43 ankles), which corresponded to an incidence of 32% (16 ankles) in the moderate-OA subgroup and 59% (27 ankles) in the severe-OA subgroup (p = 0.013). Our study demonstrates that abnormal internal rotation of the talus occurs in patients with varus ankle osteoarthritis, and is more frequently noted in severe than in moderate varus ankle osteoarthritis. (orig.)

  8. Interventions for preoperative smoking cessation

    DEFF Research Database (Denmark)

    Møller, A; Villebro, N

    2005-01-01

    Smokers have a substantially increased risk of intra- and postoperative complications. Preoperative smoking intervention may be effective in decreasing this incidence. The preoperative period may be a well chosen time to offer smoking cessation interventions due to increased patient motivation....

  9. Single-Blinded Prospective Implementation of a Preoperative Imaging Checklist for Endoscopic Sinus Surgery.

    Science.gov (United States)

    Error, Marc; Ashby, Shaelene; Orlandi, Richard R; Alt, Jeremiah A

    2018-01-01

    Objective To determine if the introduction of a systematic preoperative sinus computed tomography (CT) checklist improves identification of critical anatomic variations in sinus anatomy among patients undergoing endoscopic sinus surgery. Study Design Single-blinded prospective cohort study. Setting Tertiary care hospital. Subjects and Methods Otolaryngology residents were asked to identify critical surgical sinus anatomy on preoperative CT scans before and after introduction of a systematic approach to reviewing sinus CT scans. The percentage of correctly identified structures was documented and compared with a 2-sample t test. Results A total of 57 scans were reviewed: 28 preimplementation and 29 postimplementation. Implementation of the sinus CT checklist improved identification of critical sinus anatomy from 24% to 84% correct ( P identification of sinus anatomic variants, including those not directly included in the systematic review implemented. Conclusion The implementation of a preoperative endoscopic sinus surgery radiographic checklist improves identification of critical anatomic sinus variations in a training population.

  10. 3D CT versus axial helical CT versus conventional tomography in the classification of acetabular fractures: A ROC analysis

    International Nuclear Information System (INIS)

    Kickuth, Ralph; Laufer, Ulf; Hartung, Guido; Gruening, Christian; Stueckle, Christoph; Kirchner, Johannes

    2002-01-01

    AIM: To assess the diagnostic power of three-dimensional computed tomography (3D CT), axial helical computed tomography (CT) and conventional tomography in the classification of acetabular fractures by interdisciplinary review. MATERIALS AND METHODS: Receiver operating characteristics (ROCs) were assessed for two radiologists and two surgeons blinded to the presence of acetabular fractures in an animal model (a total of 62 porcine hips, 40 of them with artificial acetabular fractures). Main target parameter was the diagnostic accuracy in the classification of the artificial fractures following Judet et al. RESULTS: ROC analysis for radiologists showed A z values of 0·83 for 3D CT, 0·81 for axial helical CT, and 0·78 for conventional tomography; differences between the three techniques were not significant (P = 0·46-0·73). A z values for the surgeons were 0·87 for 3D CT, 0·68 for axial helical CT, and 0·60 for conventional tomography; 3D CT was significantly better than axial helical CT (P = 0·01) and conventional tomography (P = 0·001). The differences between axial helical CT and conventional tomography were not significant (P = 0·37). CONCLUSION: Acetabular fractures are best classified by 3D CT, followed by axial helical CT and conventional tomography when assessed by surgeons. 3D CT did not provide any additional significant benefit in the classification performed by radiologists. Kickuth, R. et al. (2002)

  11. Comparison of endoscopic ultrasonography and multislice spiral computed tomography for the preoperative staging of gastric cancer - results of a single institution study of 610 Chinese patients.

    Directory of Open Access Journals (Sweden)

    Xing-Yu Feng

    Full Text Available BACKGROUND: This study compared the performance of endoscopic ultrasonography (EUS and multislice spiral computed tomography (MSCT in the preoperative staging of gastric cancer. METHODOLOGY/PRINCIPAL FINDINGS: A total of 610 patients participated in this study, all of whom had undergone surgical resection, had confirmed gastric cancer and were evaluated with EUS and MSCT. Tumor staging was evaluated using the Tumor-Node-Metastasis (TNM staging and Japanese classification. The results from the imaging modalities were compared with the postoperative histopathological outcomes. The overall accuracies of EUS and MSCT for the T staging category were 76.7% and 78.2% (P=0.537, respectively. Stratified analysis revealed that the accuracy of EUS for T1 and T2 staging was significantly higher than that of MSCT (P<0.001 for both and that the accuracy of MSCT in T3 and T4 staging was significantly higher than that of EUS (P<0.001 and 0.037, respectively. The overall accuracy of MSCT was 67.2% when using the 13th edition Japanese classification, and this percentage was significantly higher than the accuracy of EUS (49.3% and MSCT (44.6% when using the 6th edition UICC classification (P<0.001 for both values. CONCLUSIONS/SIGNIFICANCE: Our results demonstrated that the overall accuracies of EUS and MSCT for preoperative staging were not significantly different. We suggest that a combination of EUS and MSCT is required for preoperative evaluation of TNM staging.

  12. Pre-operative haematological investigations in paediatric orofacial ...

    African Journals Online (AJOL)

    Pre-operative haematological investigations in paediatric orofacial cleft repair: Any relevance to management outcome? ... Aim and Objectives: To determine the value of routine pre-operative haematologic investigations in children undergoing orofacial cleft repair. Background: Although routine pre-operative laboratory ...

  13. Experimental Studies on Strength Behaviour of Notched Glass/Epoxy Laminated Composites under Uni-axial and Bi-axial Loading

    Science.gov (United States)

    Guptha, V. L. Jagannatha; Sharma, Ramesh S.

    2017-11-01

    The use of FRP composite materials in aerospace, aviation, marine, automotive and civil engineering industry has increased rapidly in recent years due to their high specific strength and stiffness properties. The structural members contrived from such composite materials are generally subjected to complex loading conditions and leads to multi-axial stress conditions at critical surface localities. Presence of notches, much required for joining process of composites, makes it further significant. The current practice of using uni-axial test data alone to validate proposed material models is inadequate leading to evaluation and consideration of bi-axial test data. In order to correlate the bi-axial strengths with the uni-axial strengths of GFRP composite laminates in the presence of a circular notch, bi-axial tests using four servo-hydraulic actuators with four load cells were carried out. To determine the in-plane strength parameters, bi-axial cruciform test specimen model was considered. Three different fibre orientations, namely, 0°, 45°, and 90° are considered with a central circular notch of 10 mm diameter in the present investigation. From the results obtained, it is observed that there is a reduction in strength of 5.36, 2.41 and 13.92% in 0°, 45°, and 90° fibre orientation, respectively, under bi-axial loading condition as compared to that of uni-axial loading in laminated composite.

  14. Preoperative staging of rectal cancer.

    Science.gov (United States)

    Smith, Neil; Brown, Gina

    2008-01-01

    Detailed preoperative staging using high resolution magnetic resonance imaging (MRI) enables the selection of patients that require preoperative therapy for tumour regression. This information can be used to instigate neoadjuvant therapy in those patients with poor prognostic features prior to disturbing the tumour bed and potentially disseminating disease. The design of trials incorporating MR assessment of prognostic factors prior to therapy has been found to be of value in assessing treatment modalities and outcomes that are targeted to these preoperative prognostic subgroups and in providing a quantifiable assessment of the efficacy of particular chemoradiation treatment protocols by comparing pre-treatment MR staging with post therapy histology assessment. At present, we are focused on achieving clear surgical margins of excision (CRM) to avoid local recurrence. We recommend that all patients with rectal cancer should undergo pre-operative MRI staging. Of these, about half will have good prognosis features (T1-T3b, N0, EMVI negative, CRM clear) and may safely undergo primary total mesorectal excision. Of the remainder, those with threatened or involved margins will certainly benefit from pre-operative chemoradiotherapy with the aim of downstaging to permit safe surgical excision. In the future, our ability to recognise features predicting distant failure, such as extramural vascular invasion (EMVI) may be used to stratify patients for neo-adjuvant systemic chemotherapy in an effort to prevent distant relapse. The optimal pre-operative treatment regimes for these patients (radiotherapy alone, systemic chemotherapy alone or combination chemo-radiotherapy) is the subject of current and future trials.

  15. Usefulness of preoperative coronary angiography and brain computed tomography in cases of coronary artery disease and cerebrovascular disease undergoing revascularization for arteriosclerosis obliterans

    International Nuclear Information System (INIS)

    Sakurada, Tall; Shibata, Yoshiki

    2003-01-01

    Coronary angiography and brain computed tomography were preoperatively performed to evaluate the clinical condition of coronary artery disease and cerebrovascular disease in 101 patients (mean age, 68.4 years) with revascularization for arteriosclerosis obliterans. Eighty patients had hypertension, 12 had diabetes, and 26 had hyperlipidemia. Seventy-one patients (70.3%) had coronary stenosis. Significant stenoses in major coronary artery branches were confirmed in 35 patients, including 13 patients with old myocardial infarction. Coronary artery bypass grafting and percutaneous coronary angioplasty were performed in 2 and 7 patients with critical stenosis, respectively. Of 57 patients, who underwent brain computed tomography, abnormalities were found in 52 patients (91.2%), including cortical infarction in 9, lacunar infarction in 35, and leukoaraiosis in 27 patients. During the follow-up period 13 patients died (including 3 cases of myocardial infarction and 3 cases of stroke). Actuarial survival rate at 5 years was 80.4%. The influence of ischemic heart disease and cerebrovascular disease on early and late mortality after surgical reconstruction for peripheral occlusive vascular disease is significant. Using visual diagnostic techniques, such as coronary angiography and brain computed tomography, long term survivor should be closely observed for multiple arteriosclerotic vascular diseases. (author)

  16. Usefulness of preoperative coronary angiography and brain computed tomography in cases of coronary artery disease and cerebrovascular disease undergoing revascularization for arteriosclerosis obliterans

    Energy Technology Data Exchange (ETDEWEB)

    Sakurada, Tall; Shibata, Yoshiki [Southern Tohoku Fukushima Hospital (Japan)

    2003-05-01

    Coronary angiography and brain computed tomography were preoperatively performed to evaluate the clinical condition of coronary artery disease and cerebrovascular disease in 101 patients (mean age, 68.4 years) with revascularization for arteriosclerosis obliterans. Eighty patients had hypertension, 12 had diabetes, and 26 had hyperlipidemia. Seventy-one patients (70.3%) had coronary stenosis. Significant stenoses in major coronary artery branches were confirmed in 35 patients, including 13 patients with old myocardial infarction. Coronary artery bypass grafting and percutaneous coronary angioplasty were performed in 2 and 7 patients with critical stenosis, respectively. Of 57 patients, who underwent brain computed tomography, abnormalities were found in 52 patients (91.2%), including cortical infarction in 9, lacunar infarction in 35, and leukoaraiosis in 27 patients. During the follow-up period 13 patients died (including 3 cases of myocardial infarction and 3 cases of stroke). Actuarial survival rate at 5 years was 80.4%. The influence of ischemic heart disease and cerebrovascular disease on early and late mortality after surgical reconstruction for peripheral occlusive vascular disease is significant. Using visual diagnostic techniques, such as coronary angiography and brain computed tomography, long term survivor should be closely observed for multiple arteriosclerotic vascular diseases. (author)

  17. Anatomic variants of interest in endoscopic sinus surgery: role of computed tomography; Variantes anatomicas de interes en cirugia endoscopica nasosinusal. Papel de la tomografia computerizada

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, S.; Arenas, J.; Fernandez, F.; Gil, S.; Guirau, M. D. [Hospital General Universitario de Alicante (Spain)

    2000-07-01

    The detailed radiological study of the anatomy of the nasal cavities and paranasal sinus is essential prior to endoscopic sinus surgery since, on the one hand, it discloses the extent of the disease and, on the other hand, it aids in the detection of the numerous anatomic variants, some of which are of great interest to the endoscopic as the lack of preoperative knowledge of them may increase the risk of complications. the objective of the present report is to review these variants, stressing those that may be associated with a greater surgical risk. Although coronal computed tomography is the technique of choice for pre endoscopy examination, certain structures and anatomic variants are better viewed in axial images. These exceptions include anterior and posterior walls of the frontal sinuses, the anatomic relationships between posterior ethmoid complex and the sphenoid sinus, the relationships between the sphenoid sinus and the optic nerve, and the detection of Onodi cells. Thus, we recommend that the radiological examination include both coronal and axial images. (Author) 16 refs.

  18. The current status and future prospects of computer-assisted hip surgery.

    Science.gov (United States)

    Inaba, Yutaka; Kobayashi, Naomi; Ike, Hiroyuki; Kubota, So; Saito, Tomoyuki

    2016-03-01

    The advances in computer assistance technology have allowed detailed three-dimensional preoperative planning and simulation of preoperative plans. The use of a navigation system as an intraoperative assistance tool allows more accurate execution of the preoperative plan, compared to manual operation without assistance of the navigation system. In total hip arthroplasty using CT-based navigation, three-dimensional preoperative planning with computer software allows the surgeon to determine the optimal angle of implant placement at which implant impingement is unlikely to occur in the range of hip joint motion necessary for daily activities of living, and to determine the amount of three-dimensional correction for leg length and offset. With the use of computer navigation for intraoperative assistance, the preoperative plan can be precisely executed. In hip osteotomy using CT-based navigation, the navigation allows three-dimensional preoperative planning, intraoperative confirmation of osteotomy sites, safe performance of osteotomy even under poor visual conditions, and a reduction in exposure doses from intraoperative fluoroscopy. Positions of the tips of chisels can be displayed on the computer monitor during surgery in real time, and staff other than the operator can also be aware of the progress of surgery. Thus, computer navigation also has an educational value. On the other hand, its limitations include the need for placement of trackers, increased radiation exposure from preoperative CT scans, and prolonged operative time. Moreover, because the position of a bone fragment cannot be traced after osteotomy, methods to find its precise position after its movement need to be developed. Despite the need to develop methods for the postoperative evaluation of accuracy for osteotomy, further application and development of these systems are expected in the future. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  19. Stall inception and warning in a single-stage transonic axial compressor with axial skewed slot casing treatment

    International Nuclear Information System (INIS)

    Lim, Byeung Jun; Kwon, Se Jin; Park, Tae Choon

    2014-01-01

    Characteristic changes in the stall inception in a single-stage transonic axial compressor with an axial skewed slot casing treatment were investigated experimentally. A rotating stall occurred intermittently in a compressor with an axial skewed slot, whereas spike-type rotating stalls occurred in the case of smooth casing. The axial skewed slot suppressed stall cell growth and increased the operating range. A mild surge, the frequency of which is the Helmholtz frequency of the compressor system, occurred with the rotating stall. The irregularity in the pressure signals at the slot bottom increased decreasing flow rate. An autocorrelation-based stall warning method was applied to the measured pressure signals. Results estimate and warn against the stall margin in a compressor with an axial skewed slot.

  20. Characterization of Multiflux Axial Compressors

    International Nuclear Information System (INIS)

    Brasnarof, Daniel; Kyung Kyu-Hyung; Rivarola, Martin; Gonzalez Jose; Florido, Pablo; Orellano, Pablo; Bergallo, Juan

    2003-01-01

    In the present work the results of analytical models of performance are compared with experimental data acquired in the multi flux axial compressor test facility, built in The Pilcaniyeu Technological Complex for the SIGMA project.We describe the experimental circuit and the data of the dispersion inside the axial compressor obtained using a tracer gas through one of the annular inlets.The attained results can be used to validate the design code for the multi flux axial compressors and SIGMA industrial plant

  1. Multidetector computed tomography arteriography in the preoperative assessment of patients with ureteropelvic junction obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Braun, Petra [Department of Radiology, Hospital de la Plana, Ctra. de Vila-real a Borriana KM. 0.5, 12540 Vila-real (Spain)]. E-mail: PetraBraun@gmx.de; Guilabert, Jose Pamies [Department of Radiology, Hospital de la Plana, Ctra. de Vila-real a Borriana KM. 0.5, 12540 Vila-real (Spain); Kazmi, Faaiza [Department of Radiology, Penn State Milton S. Hershey Medical Center (United States)

    2007-01-15

    Background: Nowadays, endoscopic management of ureteropelvic junction (UPJ) obstruction is the treatment of choice. However, in the presence of crossing vessels, the success rate of endoscopic management decreases and the risk of hemorrhagic and vascular complications rises. The purpose of this study is to evaluate patients with UPJ obstruction using contrast enhanced multidetector computed tomography (CT) angiography to aid in surgical planning and management. Patients and methods: Between 2001 and 2005, 27 patients (mean age: 43 years; age range: 17-75 years) with UPJ obstruction were studied with multidetector CT angiography. Identification and characterization of crossing vessels was performed with multidirectional images and three-directional reconstructions. Results: 12 patients (44%) were found to have 16 crossing vessels (vessels in contact with the UPJ or within a vicinity of less than 2 mm). Nine of these vessels were arteries and seven were veins. Nine vessels crossed anteriorly, two posteriorly, and one anteromedially. Endopyelotomy was contraindicated in these 12 patients due to the presence of crossing vessels. Eleven out of the 12 patients underwent a pyeloplasty by open surgery or laparoscopy, where the presence of crossing vessels was confirmed. One of the 12 patients did not undergo surgery. Conclusion: Multidetector CT angiography permits an adequate preoperative assessment of patients with UPJ obstruction as it is able to identify the presence and location of crossing vessels. Furthermore, it allows to study in detail the anatomy of the renal area and its vascular variants.

  2. Geometric radiation exchange factors for axial radiative transfer in an LWR core filled with absorbing-emitting gases

    International Nuclear Information System (INIS)

    Chan, S.H.; Cho, D.H.

    1984-01-01

    A reactor core filled with an emitting-absorbing mixture (like steam, hydrogen gas and fission gases) is considered. Analysis is provided to evaluate axial radiative heat exchange of a rod bundle with a nonuniform axial temperature distribution. The necessary radiation exchange shape factors (geometric mean absorptance, emittance and transmittance) between segments of the complex rod bundle arrangement are presented. They are applicable to arbitrary sizes of segments, well suited for numerical computations

  3. An investigation of inconsistent projections and artefacts in multi-pinhole SPECT with axially aligned pinholes

    International Nuclear Information System (INIS)

    Kench, P L; Meikle, S R; Lin, J; Gregoire, M C

    2011-01-01

    Multiple pinholes are advantageous for maximizing the use of the available field of view (FOV) of compact small animal single photon emission computed tomography (SPECT) detectors. However, when the pinholes are aligned axially to optimize imaging of extended objects, such as rodents, multiplexing of the pinhole projections can give rise to inconsistent data which leads to 'ghost point' artefacts in the reconstructed volume. A novel four pinhole collimator with a baffle was designed and implemented to eliminate these inconsistent projections. Simulation and physical phantom studies were performed to investigate artefacts from axially aligned pinholes and the efficacy of the baffle in removing inconsistent data and, thus, reducing reconstruction artefacts. SPECT was performed using a Defrise phantom to investigate the impact of collimator design on FOV utilization and axial blurring effects. Multiple pinhole SPECT acquired with a baffle had fewer artefacts and improved quantitative accuracy when compared to SPECT acquired without a baffle. The use of four pinholes positioned in a square maximized the available FOV, increased acquisition sensitivity and reduced axial blurring effects. These findings support the use of a baffle to eliminate inconsistent projection data arising from axially aligned pinholes and improve small animal SPECT reconstructions.

  4. Axial Tomography from Digitized Real Time Radiography

    Science.gov (United States)

    Zolnay, A. S.; McDonald, W. M.; Doupont, P. A.; McKinney, R. L.; Lee, M. M.

    1985-01-18

    Axial tomography from digitized real time radiographs provides a useful tool for industrial radiography and tomography. The components of this system are: x-ray source, image intensifier, video camera, video line extractor and digitizer, data storage and reconstruction computers. With this system it is possible to view a two dimensional x-ray image in real time at each angle of rotation and select the tomography plane of interest by choosing which video line to digitize. The digitization of a video line requires less than a second making data acquisition relatively short. Further improvements on this system are planned and initial results are reported.

  5. Reducing Torque Ripples of the Axial Flux PM Motors by Magnet Stepping and Shifting

    Directory of Open Access Journals (Sweden)

    E. Cetin

    2018-02-01

    Full Text Available Higher efficiency on electric machines is the research goal of many studies. An example is the axial flux permanent magnet machines. These machines have some advantages like their watt/kg efficiency and torque density. This study aims to develop the performance characteristics of the axial flux permanent magnet machines. A new rotor magnet poles design in axial flux machines is suggested to mitigate the torque ripples. The method of stepping and shifting of the magnets is used. Two different designs are compared to verify the proposed approach. 3D finite element analysis is used for simulations. Torque ripple and back electromotive force waveforms are obtained from computer analysis. As a conclusion, the suggested method is found to be useable and mitigates the torque ripples. In addition to that, back EMF waveforms are turned to sinusoidal by the suggested design.

  6. Axial power distribution calculation using a neural network in the nuclear reactor core

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y H; Cha, K H; Lee, S H [Korea Electric Power Research Institute, Taejon (Korea, Republic of)

    1998-12-31

    This paper is concerned with an algorithm based on neural networks to calculate the axial power distribution using excore detector signals in the nuclear reactor core. The fundamental basis of the algorithm is that the detector response can be fairly accurately estimated using computational codes. In other words, the training set, which represents relationship between detector signals and axial power distributions, for the neural network can be obtained through calculations instead of measurements. Application of the new method to the Yonggwang nuclear power plant unit 3 (YGN-3) shows that it is superior to the current algorithm in place. 7 refs., 4 figs. (Author)

  7. Axial power distribution calculation using a neural network in the nuclear reactor core

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y. H.; Cha, K. H.; Lee, S. H. [Korea Electric Power Research Institute, Taejon (Korea, Republic of)

    1997-12-31

    This paper is concerned with an algorithm based on neural networks to calculate the axial power distribution using excore detector signals in the nuclear reactor core. The fundamental basis of the algorithm is that the detector response can be fairly accurately estimated using computational codes. In other words, the training set, which represents relationship between detector signals and axial power distributions, for the neural network can be obtained through calculations instead of measurements. Application of the new method to the Yonggwang nuclear power plant unit 3 (YGN-3) shows that it is superior to the current algorithm in place. 7 refs., 4 figs. (Author)

  8. [Preoperative fasting. An update].

    Science.gov (United States)

    Spies, C D; Breuer, J P; Gust, R; Wichmann, M; Adolph, M; Senkal, M; Kampa, U; Weissauer, W; Schleppers, A; Soreide, E; Martin, E; Kaisers, U; Falke, K J; Haas, N; Kox, W J

    2003-11-01

    In Germany the predominant standard of preoperative care for elective surgery is fasting after midnight, with the aim of reducing the risk of pulmonary aspiration. However, for the past several years the scientific evidence supporting such a practice has been challenged. Experimental and clinical studies prove a reliable gastric emptying within 2 h suggesting that, particularly for limited intake of clear fluids up to 2 h preoperatively, there would be no increased risk for the patient. In addition, the general incidence of pulmonary aspiration during general anaesthesia (before induction, during surgery and during recovery) is extremely low, has a good prognosis and is more a consequence of insufficient airway protection and/or inadequate anaesthetic depth rather than due to the patient's fasting state. Therefore, primarily to decrease perioperative discomfort for patients, several national anaesthesia societies have changed their guidelines for preoperative fasting. They recommend a more liberal policy regarding per os intake of both liquid and solid food, with consideration of certain conditions and contraindications. The following article reviews the literature and gives an overview of the scientific background on which the national guidelines are based. The intention of this review is to propose recommendations for preoperative fasting regarding clear fluids for Germany as well.

  9. Solution of the Fokker-Planck equation for axially-channeled relativistic electrons

    International Nuclear Information System (INIS)

    Muralev, V.A.; Telegin, V.I.

    1981-01-01

    A method of the two dimensional kinetic equation of the Fokker-Planck type for axially-channeled electrons is proposed. This equation has been obtained recently by Beloshitsky and Kumakhov to describe the diffusion of channeling negative particles over the transverse energy and angular momentum. The results of computation of the dechanneling function of 1 GeV electrons in tungsten are presented. (author)

  10. Pre-operative biliary drainage for obstructive jaundice

    Science.gov (United States)

    Fang, Yuan; Gurusamy, Kurinchi Selvan; Wang, Qin; Davidson, Brian R; Lin, He; Xie, Xiaodong; Wang, Chaohua

    2014-01-01

    Background Patients with obstructive jaundice have various pathophysiological changes that affect the liver, kidney, heart, and the immune system. There is considerable controversy as to whether temporary relief of biliary obstruction prior to major definitive surgery (pre-operative biliary drainage) is of any benefit to the patient. Objectives To assess the benefits and harms of pre-operative biliary drainage versus no pre-operative biliary drainage (direct surgery) in patients with obstructive jaundice (irrespective of a benign or malignant cause). Search methods We searched the Cochrane Hepato-Biliary Group Controlled Trials Register, Cochrane Central Register of Controlled Clinical Trials (CENTRAL) in The Cochrane Library, MEDLINE, EMBASE, and Science Citation Index Expanded until February 2012. Selection criteria We included all randomised clinical trials comparing biliary drainage followed by surgery versus direct surgery, performed for obstructive jaundice, irrespective of the sample size, language, and publication status. Data collection and analysis Two authors independently assessed trials for inclusion and extracted data. We calculated the risk ratio (RR), rate ratio (RaR), or mean difference (MD) with 95% confidence intervals (CI) based on the available patient analyses. We assessed the risk of bias (systematic overestimation of benefit or systematic underestimation of harm) with components of the Cochrane risk of bias tool. We assessed the risk of play of chance (random errors) with trial sequential analysis. Main results We included six trials with 520 patients comparing pre-operative biliary drainage (265 patients) versus no pre-operative biliary drainage (255 patients). Four trials used percutaneous transhepatic biliary drainage and two trials used endoscopic sphincterotomy and stenting as the method of pre-operative biliary drainage. The risk of bias was high in all trials. The proportion of patients with malignant obstruction varied between 60

  11. Comparison of computed tomography scout based reference point localization to conventional film and axial computed tomography.

    Science.gov (United States)

    Jiang, Lan; Templeton, Alistair; Turian, Julius; Kirk, Michael; Zusag, Thomas; Chu, James C H

    2011-01-01

    Identification of source positions after implantation is an important step in brachytherapy planning. Reconstruction is traditionally performed from films taken by conventional simulators, but these are gradually being replaced in the clinic by computed tomography (CT) simulators. The present study explored the use of a scout image-based reconstruction algorithm that replaces the use of traditional film, while exhibiting low sensitivity to metal-induced artifacts that can appear in 3D CT methods. In addition, the accuracy of an in-house graphical software implementation of scout-based reconstruction was compared with seed location reconstructions for 2 phantoms by conventional simulator and CT measurements. One phantom was constructed using a planar fixed grid of 1.5-mm diameter ball bearings (BBs) with 40-mm spacing. The second was a Fletcher-Suit applicator embedded in Styrofoam (Dow Chemical Co., Midland, MI) with one 3.2-mm-diameter BB inserted into each of 6 surrounding holes. Conventional simulator, kilovoltage CT (kVCT), megavoltage CT, and scout-based methods were evaluated by their ability to calculate the distance between seeds (40 mm for the fixed grid, 30-120 mm in Fletcher-Suit). All methods were able to reconstruct the fixed grid distances with an average deviation of <1%. The worst single deviations (approximately 6%) were exhibited in the 2 volumetric CT methods. In the Fletcher-Suit phantom, the intermodality agreement was within approximately 3%, with the conventional sim measuring marginally larger distances, with kVCT the smallest. All of the established reconstruction methods exhibited similar abilities to detect the distances between BBs. The 3D CT-based methods, with lower axial resolution, showed more variation, particularly with the smaller BBs. With a software implementation, scout-based reconstruction is an appealing approach because it simplifies data acquisition over film-based reconstruction without requiring any specialized equipment

  12. [Inflammatory spinal diseases: axial spondyloarthritis : Central importance of imaging].

    Science.gov (United States)

    Baraliakos, X; Fruth, M; Kiltz, U; Braun, J

    2017-03-01

    The diagnosis of axial spondyloarthritis (axSpA) includes classical ankylosing spondylitis (AS) as well as earlier stages and abortive courses of the disease, in which structural alterations have not yet occurred. These are classified as non-radiographic axSpA (nr-axSpa). Inflammatory changes in the entire axial skeleton are characteristic for axSpA and can be visualized by magnetic resonance imaging (MRI), while in most patients structural alterations, such as new bone formation with syndesmophytes and ankylosis develop in the later course of the disease. These bony alterations can best be visualized by conventional radiography and by computed tomography. Certain MRI sequences are nowadays considered as the standard method for depiction of inflammatory changes in axSpA. The introduction of MRI has led to a paradigm shift for this disease because the inflammatory lesions characteristic for the disease can be visualized at an early stage using appropriate MRI sequences.

  13. 18 F-fluorodeoxyglucose positron emission tomography-computed tomography for preoperative lymph node staging in patients undergoing radical cystectomy for bladder cancer: a prospective study.

    Science.gov (United States)

    Hitier-Berthault, Maryam; Ansquer, Catherine; Branchereau, Julien; Renaudin, Karine; Bodere, Françoise; Bouchot, Olivier; Rigaud, Jérôme

    2013-08-01

    The objective of our study was to analyze the diagnostic performance of (18) F-fluorodeoxyglucose positron emission tomography-computed tomography for lymph node staging in patients with bladder cancer before radical cystectomy and to compare it with that of computed tomography. A total of 52 patients operated on between 2005 and 2010 were prospectively included in this prospective, mono-institutional, open, non-randomized pilot study. Patients who had received neoadjuvant chemotherapy or radiotherapy were excluded. (18) F-fluorodeoxyglucose positron emission tomography-computed tomography in addition to computed tomography was carried out for lymph node staging of bladder cancer before radical cystectomy. Lymph node dissection during radical cystectomy was carried out. Findings from (18) F-fluorodeoxyglucose positron emission tomography-computed tomography and computed tomography were compared with the results of definitive histological examination of the lymph node dissection. The diagnostic performance of the two imaging modalities was assessed and compared. The mean number of lymph nodes removed during lymph node dissection was 16.5 ± 10.9. Lymph node metastasis was confirmed on histological examination in 22 cases (42.3%). This had been suspected in five cases (9.6%) on computed tomography and in 12 cases (23.1%) on (18) F-fluorodeoxyglucose positron emission tomography-computed tomography. Sensitivity, specificity, positive predictive value, negative predictive value, relative risk and accuracy were 9.1%, 90%, 40%, 57.4%, 0.91 and 55.7%, respectively, for computed tomography, and 36.4%, 86.7%, 66.7%, 65%, 2.72, 65.4%, respectively, for (18) F-fluorodeoxyglucose positron emission tomography-computed tomography. (18) F-fluorodeoxyglucose positron emission tomography-computed tomography is more reliable than computed tomography for preoperative lymph node staging in patients with invasive bladder carcinoma undergoing radical cystectomy. © 2012 The Japanese

  14. A preoperative mathematic model for computed tomographic guided microwave ablation treatment of hepatic dome tumors.

    Science.gov (United States)

    Gao, Fei; Wang, Guo-Bao; Xiang, Zhan-Wang; Yang, Bin; Xue, Jing-Bing; Mo, Zhi-Qiang; Zhong, Zhi-Hui; Zhang, Tao; Zhang, Fu-Jun; Fan, Wei-Jun

    2016-05-03

    This study sought to prospectively evaluate the feasibility and safety of a preoperative mathematic model for computed tomographic(CT) guided microwave(MW) ablation treatment of hepatic dome tumors. This mathematic model was a regular cylinder quantifying appropriate puncture routes from the bottom up. A total of 103 patients with hepatic dome tumors were enrolled and randomly divided into 2 groups based on whether this model was used or not: Group A (using the model; n = 43) versus Group B (not using the model; n = 60). All tumors were treated by CT-guided MW ablation and follow-up contrast CT were reviewed. The average number of times for successful puncture, average ablation time, and incidence of right shoulder pain were less in Group A than Group B (1.4 vs. 2.5, P = 0.001; 8.8 vs. 11.1 minutes, P = 0.003; and 4.7% vs. 20%, P = 0.039). The technical success rate was higher in Group A than Group B (97.7% vs. 85.0%, P = 0.032). There were no significant differences between the two groups in primary and secondary technique efficacy rates (97.7% vs. 88.3%, P = 0.081; 90.0% vs. 72.7%, P = 0.314). No major complications occurred in both groups. The mathematic model of regular cylinder is feasible and safe for CT-guided MW ablation in treating hepatic dome tumors.

  15. Approach to improve the axial power distribution for the application of a core protection system

    International Nuclear Information System (INIS)

    Koo, Bon Seung; Cho, Jin Young; Song, Jae Seung; Lee, Chung Chan

    2008-01-01

    A Core Protection Calculator System (CPCS) is a digital computer based on a safety system for generating trip signals based on a calculation of the Departure from Nucleate Boiling Ratio (DNBR) and the Local Power Density (LPD) by using several on-line measured system parameters including 3-level ex-core detector signals. A few approaches to improve the axial power distribution for the application of a core protection system were performed. For the Yonggwang unit 3 (cycle 1), axial power distributions were synthesized by applying the cubic spline method and compared with the neutronics code results. Several new cubic spline function sets were generated for the drastically distorted axial shapes for a 3-level ex-core detector system. In addition, synthesized axial shapes with a 5-level ex-core detector signals were compared with the conventional 3-level detector results. It demonstrates that the newly generated function sets appear to be better than that of the conventional CPC from the aspect of an axial power synthesis, particularly for the heavily distorted shapes. Moreover, synthesis of an axial power distribution using 5-level ex-core detector signals appears to be better than that of the 3-level ex-core detector signals. From the above results, improvement of the thermal margin is expected because of an uncertainty decreasing a core protection system. (authors)

  16. Multidetector computed tomography for preoperative evaluation of vascular anatomy in living renal donors.

    Science.gov (United States)

    Türkvatan, Aysel; Akinci, Serkan; Yildiz, Sener; Olçer, Tülay; Cumhur, Turhan

    2009-04-01

    Currently, multidetector computed tomographic (MDCT) angiography has become a noninvasive alternative imaging modality to catheter renal angiography for the evaluation of renal vascular anatomy in living renal donors. In this study, we investigated the diagnostic accuracy of 16-slice MDCT in the preoperative assessment of living renal donors. Fifty-nine consecutive living renal donors (32 men, 27 women) underwent MDCT angiography followed by open donor nephrectomy. All MDCT studies were performed by using a 16-slice MDCT scanner with the same protocol consisting of arterial and nephrographic phases followed by conventional abdominal radiography. The MDCT images were assessed retrospectively for the number and branching pattern of the renal arteries and for the number and presence of major or minor variants of the renal veins. The results were compared with open surgical results. The sensitivity and specificity of MDCT for the detection of anatomic variants of renal arteries including the accessory arteries (n = 9), early arterial branching (n = 7) and major renal venous anomalies including the accessory renal veins (n = 3), late venous confluence (n = 4), circumaortic (n = 2) or retroaortic (n = 3) left renal veins were 100%. However, the sensitivity for identification of minor venous variants was 79%. All of three ureteral duplications were correctly identified at excretory phase conventional abdominal radiography. Sixteen-slice MDCT is highly accurate for the identification of anatomic variants of renal arteries and veins. Dual-phase MDCT angiography including arterial and nephrographic phases followed by conventional abdominal radiography enables complete assessment of renal donors without significant increase of radiation dose. However, the evaluation of minor venous variants may be problematic because of their small diameters and poor opacification.

  17. Stability management of high speed axial flow compressor stage through axial extensions of bend skewed casing treatment

    Directory of Open Access Journals (Sweden)

    DilipkumarBhanudasji Alone

    2016-09-01

    Full Text Available This paper presents the experimental results to understand the performance of moderately loaded high speed single stage transonic axial flow compressor subjected to various configurations of axial extensions of bend skewed casing treatment with moderate porosity. The bend skewed casing treatment of 33% porosity was coupled with rectangular plenum chamber of depth equal to the slots depth. The five axial extensions of 20%, 40%, 60%, 80% and 100% were used for the experimental evaluations of compressor performance. The main objective was to identify the optimum extension of the casing treatment with reference to rotor leading edge which results in maximum stall margin improvements with minimum loss in the stage efficiency. At each axial extension the compressor performance is distinctive. The improvement in the stall margin was very significant at some axial extensions with 4%–5% penalty in the stage efficiency. The compressors stage shows recovery in terms of efficiency at lower axial extensions of 20% and 40% with increase in the peak stage efficiency. Measurements of flow parameters showed the typical behaviors at near stall flow conditions. Hot wire sensor was placed at the rotor upstream in the tip region to capture the oscillations in the inlet axial and tangential velocities at stall conditions. In the absence of casing treatment the compressor exhibit abrupt stall with very high oscillations in the inlet axial and tangential velocity of the flow. The extents of oscillations reduce with bend skewed casing treatment. Few measurements were also performed in the plenum chamber and salient results are presented in this paper.

  18. High energy injury is a risk factor for preoperative venous thromboembolism in the patients with hip fractures: A prospective observational study.

    Science.gov (United States)

    Park, Jin Sup; Jang, Jae Hoon; Park, Ki Young; Moon, Nam Hoon

    2018-06-01

    The purpose of this study was to identify the incidence of preoperative venous thromboembolism (VTE), and determine if high energy hip fracture affects preoperative VTE occurrence. Three-hundred nine patients (244 low and 61 high energy injuries) treated between March 2015 and March 2017 were included in this study. Indirect multidetector computed tomographic venography for the detection of preoperative VTE was performed at admission. The incidence of preoperative VTE was compared between high and low energy injury hip fractures. Logistic regression analysis was used to identify independent risk factors for preoperative VTE. The overall incidence of preoperative VTE was 18.4% (56 of 305 patients). Preoperative VTE was identified in 17 (27.9%) and 39 (16.0%) patients in the high and low energy injury groups, respectively (p = 0.034). Multivariate logistic regression analysis showed that high energy injury, history of VTE, and myeloproliferative disease were significant predictive factors of preoperative VTE (OR = 2.451; 95% CI = 1.227-4.896, OR = 11.174; 95% CI = 3.500-35.673, OR = 6.936; 95% CI = 1.641-29.321, respectively) CONCLUSION: Because high energy hip fracture is significantly associated with preoperative VTE occurrence, preoperative evaluation and proper thromboprophylaxis should be performed for patients with a high-energy hip fracture. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. On renormalization of axial anomaly

    International Nuclear Information System (INIS)

    Efremov, A.V.; Teryaev, O.V.

    1989-01-01

    It is shown that multiplicative renormalization of the axial singlet current results in renormalization of the axial anomaly in all orders of perturbation theory. It is a necessary condition for the Adler - Bardeen theorem being valid. 10 refs.; 2 figs

  20. Predicting the Coupling Properties of Axially-Textured Materials

    Science.gov (United States)

    Fuentes-Cobas, Luis E.; Muñoz-Romero, Alejandro; Montero-Cabrera, María E.; Fuentes-Montero, Luis; Fuentes-Montero, María E.

    2013-01-01

    A description of methods and computer programs for the prediction of “coupling properties” in axially-textured polycrystals is presented. Starting data are the single-crystal properties, texture and stereography. The validity and proper protocols for applying the Voigt, Reuss and Hill approximations to estimate coupling properties effective values is analyzed. Working algorithms for predicting mentioned averages are given. Bunge’s symmetrized spherical harmonics expansion of orientation distribution functions, inverse pole figures and (single and polycrystals) physical properties is applied in all stages of the proposed methodology. The established mathematical route has been systematized in a working computer program. The discussion of piezoelectricity in a representative textured ferro-piezoelectric ceramic illustrates the application of the proposed methodology. Polycrystal coupling properties, predicted by the suggested route, are fairly close to experimentally measured ones. PMID:28788370

  1. Predicting the Coupling Properties of Axially-Textured Materials

    Directory of Open Access Journals (Sweden)

    María E. Fuentes-Montero

    2013-10-01

    Full Text Available A description of methods and computer programs for the prediction of “coupling properties” in axially-textured polycrystals is presented. Starting data are the single-crystal properties, texture and stereography. The validity and proper protocols for applying the Voigt, Reuss and Hill approximations to estimate coupling properties effective values is analyzed. Working algorithms for predicting mentioned averages are given. Bunge’s symmetrized spherical harmonics expansion of orientation distribution functions, inverse pole figures and (single and polycrystals physical properties is applied in all stages of the proposed methodology. The established mathematical route has been systematized in a working computer program. The discussion of piezoelectricity in a representative textured ferro-piezoelectric ceramic illustrates the application of the proposed methodology. Polycrystal coupling properties, predicted by the suggested route, are fairly close to experimentally measured ones.

  2. Preoperative assessment of trigeminal neuralgia and hemifacial spasm using constructive interference in steady state-three-dimensional fourier transformation magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yamakami, Iwao; Kobayashi, Eiichi; Hirai, Shinji; Yamaura, Akira [Chiba Univ. (Japan). School of Medicine

    2000-11-01

    Results of microvascular decompression (MVD) for trigeminal neuralgia (TN) and hemifacial spasm (HFS) may be improved by accurate preoperative assessment of neurovascular relationships at the root entry/exit zone (REZ). Constructive interference in steady state (CISS)-three-dimensional Fourier transformation (3DFT) magnetic resonance (MR) imaging was evaluated for visualizing the neurovascular relationships at the REZ. Fourteen patients with TN and eight patients with HFS underwent MR imaging using CISS-3DFT and 3D fast inflow with steady-state precession (FISP) sequences. Axial images of the cerebellopontine angle (CPA) obtained by the two sequences were reviewed to assess the neurovascular relationships at the REZ of the trigeminal and facial nerves. Eleven patients subsequently underwent MVD. Preoperative MR imaging findings were related to surgical observations and results. CISS MR imaging provided excellent contrast between the cranial nerves, small vessels, and cerebrospinal fluid (CSF) in the CPA. CISS was significantly better than FISP for delineating anatomic detail in the CPA (trigeminal and facial nerves, petrosal vein) and abnormal neurovascular relationships responsible for TN and HFS (vascular contact and deformity at the REZ). Preoperative CISS MR imaging demonstrated precisely the neurovascular relationships at the REZ and identified the offending artery in all seven patients with TN undergoing MVD. CISS MR imaging has high resolution and excellent contrast between cranial nerves, small vessels, and CSF, so can precisely and accurately delineate normal and abnormal neurovascular relationships at the REZ in the CPA, and is a valuable preoperative examination for MVD. (author)

  3. Preoperative assessment of trigeminal neuralgia and hemifacial spasm using constructive interference in steady state-three-dimensional fourier transformation magnetic resonance imaging

    International Nuclear Information System (INIS)

    Yamakami, Iwao; Kobayashi, Eiichi; Hirai, Shinji; Yamaura, Akira

    2000-01-01

    Results of microvascular decompression (MVD) for trigeminal neuralgia (TN) and hemifacial spasm (HFS) may be improved by accurate preoperative assessment of neurovascular relationships at the root entry/exit zone (REZ). Constructive interference in steady state (CISS)-three-dimensional Fourier transformation (3DFT) magnetic resonance (MR) imaging was evaluated for visualizing the neurovascular relationships at the REZ. Fourteen patients with TN and eight patients with HFS underwent MR imaging using CISS-3DFT and 3D fast inflow with steady-state precession (FISP) sequences. Axial images of the cerebellopontine angle (CPA) obtained by the two sequences were reviewed to assess the neurovascular relationships at the REZ of the trigeminal and facial nerves. Eleven patients subsequently underwent MVD. Preoperative MR imaging findings were related to surgical observations and results. CISS MR imaging provided excellent contrast between the cranial nerves, small vessels, and cerebrospinal fluid (CSF) in the CPA. CISS was significantly better than FISP for delineating anatomic detail in the CPA (trigeminal and facial nerves, petrosal vein) and abnormal neurovascular relationships responsible for TN and HFS (vascular contact and deformity at the REZ). Preoperative CISS MR imaging demonstrated precisely the neurovascular relationships at the REZ and identified the offending artery in all seven patients with TN undergoing MVD. CISS MR imaging has high resolution and excellent contrast between cranial nerves, small vessels, and CSF, so can precisely and accurately delineate normal and abnormal neurovascular relationships at the REZ in the CPA, and is a valuable preoperative examination for MVD. (author)

  4. High temperature co-axial winding transformers

    Science.gov (United States)

    Divan, Deepakraj M.; Novotny, Donald W.

    1993-01-01

    The analysis and design of co-axial winding transformers is presented. The design equations are derived and the different design approaches are discussed. One of the most important features of co-axial winding transformers is the fact that the leakage inductance is well controlled and can be made low. This is not the case in conventional winding transformers. In addition, the power density of co-axial winding transformers is higher than conventional ones. Hence, using co-axial winding transformers in a certain converter topology improves the power density of the converter. The design methodology used in meeting the proposed specifications of the co-axial winding transformer specifications are presented and discussed. The final transformer design was constructed in the lab. Co-axial winding transformers proved to be a good choice for high power density and high frequency applications. They have a more predictable performance compared with conventional transformers. In addition, the leakage inductance of the transformer can be controlled easily to suit a specific application. For space applications, one major concern is the extraction of heat from power apparatus to prevent excessive heating and hence damaging of these units. Because of the vacuum environment, the only way to extract heat is by using a cold plate. One advantage of co-axial winding transformers is that the surface area available to extract heat from is very large compared to conventional transformers. This stems from the unique structure of the co-axial transformer where the whole core surface area is exposed and can be utilized for cooling effectively. This is a crucial issue here since most of the losses are core losses.

  5. Comparison of positions of the trochlear groove line and the vertical midline of the pericondylar rectangle on axial computed tomography: a retrospective pilot study

    International Nuclear Information System (INIS)

    Nizic, Dinko

    2012-01-01

    To compare the positions of the trochlear groove (TG) line and the vertical midline of the pericondylar rectangle on axial computed tomography (CT). A retrospective pilot study was conducted in February and March 2011 comprising 14 knees in 9 consecutive patients with patellofemoral pain, a normal trochlear angle (124 -145 ), and no medical record of prior knee surgery. After the axial CT image displaying the center of the trochlear groove (''reference cut'') with a normal trochlear angle was identified, the pericondylar rectangle was drawn and located in the first quadrant of the Cartesian rectangular coordinate system. The x-coordinates of the vertical lines passing through the most posterior point of the trochlear groove (TG line) and the midpoints of the horizontal sides of the pericondylar rectangle (vertical midline) were obtained at 2-week intervals and statistically analyzed as matched pairs for differences (Wilcoxon signed rank test), agreements (Bland-Altman plot, intraclass correlation coefficient [ICC]) and relative variations (coefficient of variation [CV]). There were no statistically significant differences between matched pairs (2-tailed p from 0.583 to 0.641) whereas the agreements were substantial (bias = -0.37 and -0.45 respectively, ICC = 0.688 and 0.670 respectively) to almost perfect for duplicate measurements (bias = 0.11 and 0.04 respectively, ICC = 0.975 and 0.998 respectively), with much less relative variation with regard to the vertical midline (CV = 1.22% to CV = 0.34% respectively). The positions of the TG line and the vertical midline of the pericondylar rectangle on axial CT were identical. The latter was identified regardless of trochlear morphology. (orig.)

  6. Comparison of positions of the trochlear groove line and the vertical midline of the pericondylar rectangle on axial computed tomography: a retrospective pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Nizic, Dinko [Zagreb University Hospital Center, Clinical Institute of Diagnostic and Interventional Radiology, Zagreb (Croatia)

    2012-09-15

    To compare the positions of the trochlear groove (TG) line and the vertical midline of the pericondylar rectangle on axial computed tomography (CT). A retrospective pilot study was conducted in February and March 2011 comprising 14 knees in 9 consecutive patients with patellofemoral pain, a normal trochlear angle (124 -145 ), and no medical record of prior knee surgery. After the axial CT image displaying the center of the trochlear groove (''reference cut'') with a normal trochlear angle was identified, the pericondylar rectangle was drawn and located in the first quadrant of the Cartesian rectangular coordinate system. The x-coordinates of the vertical lines passing through the most posterior point of the trochlear groove (TG line) and the midpoints of the horizontal sides of the pericondylar rectangle (vertical midline) were obtained at 2-week intervals and statistically analyzed as matched pairs for differences (Wilcoxon signed rank test), agreements (Bland-Altman plot, intraclass correlation coefficient [ICC]) and relative variations (coefficient of variation [CV]). There were no statistically significant differences between matched pairs (2-tailed p from 0.583 to 0.641) whereas the agreements were substantial (bias = -0.37 and -0.45 respectively, ICC = 0.688 and 0.670 respectively) to almost perfect for duplicate measurements (bias = 0.11 and 0.04 respectively, ICC = 0.975 and 0.998 respectively), with much less relative variation with regard to the vertical midline (CV = 1.22% to CV = 0.34% respectively). The positions of the TG line and the vertical midline of the pericondylar rectangle on axial CT were identical. The latter was identified regardless of trochlear morphology. (orig.)

  7. The Design Method of Axial Flow Runners Focusing on Axial Flow Velocity Uniformization and Its Application to an Ultra-Small Axial Flow Hydraulic Turbine

    Directory of Open Access Journals (Sweden)

    Yasuyuki Nishi

    2016-01-01

    Full Text Available We proposed a portable and ultra-small axial flow hydraulic turbine that can generate electric power comparatively easily using the low head of open channels such as existing pipe conduits or small rivers. In addition, we proposed a simple design method for axial flow runners in combination with the conventional one-dimensional design method and the design method of axial flow velocity uniformization, with the support of three-dimensional flow analysis. Applying our design method to the runner of an ultra-small axial flow hydraulic turbine, the performance and internal flow of the designed runner were investigated using CFD analysis and experiment (performance test and PIV measurement. As a result, the runners designed with our design method were significantly improved in turbine efficiency compared to the original runner. Specifically, in the experiment, a new design of the runner achieved a turbine efficiency of 0.768. This reason was that the axial component of absolute velocity of the new design of the runner was relatively uniform at the runner outlet in comparison with that of the original runner, and as a result, the negative rotational flow was improved. Thus, the validity of our design method has been verified.

  8. The imprint of the equation of state on the axial w-modes of oscillating neutron stars

    International Nuclear Information System (INIS)

    Benhar, O.; Berti, E.; Ferrari, V.

    2001-01-01

    We study the dependence of the pulsation frequencies of axial quasi-normal modes of a nonrotating neutron star upon the equation of state describing the star interior. The complex frequencies corresponding to a set of equations of state based on different physical assumptions have been computed. The numerical results, which appear to depend primarily on the stiffness of the equation of state, show that axial gravitational waves carry relevant information on both the structure of neutron star matter and the nature of the hadronic interactions. (author)

  9. Origin of axial current in scyllac

    International Nuclear Information System (INIS)

    Sugisaki, K.

    1975-12-01

    The origin of the axial current observed in Scyllac (a high beta stellarator experiment) is discussed. A shaped coil and/or helical winding produce rotational transform which links magnetic lines of force to the plasma column and the axial current is induced electromagnetically. This phenomenon is inherent in a pulsed high-beta stellarator. The rotational transform produced by the induced axial current is much smaller than that associated with the l = 1, 0 equilibrium fields. The effect of the axial current on the equilibrium and stability of the plasma column is thus small. It is also shown that the magnetic field shear near a plasma surface is very strong

  10. Preoperative Surgical Discussion and Information Retention by Patients.

    Science.gov (United States)

    Feiner, David E; Rayan, Ghazi M

    2016-10-01

    To assess how much information communicated to patients is understood and retained after preoperative discussion of upper extremity procedures. A prospective study was designed by recruiting patients prior to undergoing upper extremity surgical procedures after a detailed discussion of their operative technique, postoperative care and treatment outcomes. Patients were given the same 20-item questionnaire to fill out twice, at two pre operative visits. An independent evaluator filled out a third questionnaire as a control. Various discussion points of the survey were compared among the 3 questionnaires and retained information and perceived comprehension were evaluated. The average patients' age was 50.3 (27-75) years The average time between the two surveys preoperative 1 and preoperative 2 was 40.7 (7-75) days,. The average patient had approximately 2 years of college or an associate's degree. Patients initially retained 73% (52-90%) of discussion points presented during preoperative 1 and 61% (36-85%) of the information at preoperative 2 p = .002. 50% of patients felt they understood 100% of the discussion, this dropped to only 10% at their preoperative 2 visit. 15% of our patients did not know what type of anesthesia they were having at preoperative 2. A communication barrier between patients and physicians exists when patients are informed about their preoperative surgical discussion. The retention of information presented is worsened with elapsing time from the initial preoperative discussion to the second preoperative visit immediately prior to surgery. Methods to enhance patients' retention of information prior to surgery must be sought and implemented which will improve patients' treatment outcome.

  11. Preoperative Alcohol Consumption and Postoperative Complications

    DEFF Research Database (Denmark)

    Eliasen, Marie; Grønkjær, Marie; Skov-Ettrup, Lise Skrubbeltrang

    2013-01-01

    OBJECTIVE:: To systematically review and summarize the evidence of the association between preoperative alcohol consumption and postoperative complications elaborated on complication type. BACKGROUND:: Conclusions in studies on preoperative alcohol consumption and postoperative complications have...... been inconsistent. METHODS:: A systematic review and meta-analysis based on a search in MEDLINE, EMBASE, CINAHL, and PsycINFO citations. Included were original studies of the association between preoperative alcohol consumption and postoperative complications occurring within 30 days of the operation.......30-2.49), prolonged stay at the hospital (RR = 1.24; 95% CI: 1.18-1.31), and admission to intensive care unit (RR = 1.29; 95% CI: 1.03-1.61). Clearly defined high alcohol consumption was associated with increased risk of postoperative mortality (RR = 2.68; 95% CI: 1.50-4.78). Low to moderate preoperative alcohol...

  12. Preoperative CT-Angiography Predicts Ex Vivo Vein Length for Right Kidneys After Laparoscopic Donor Nephrectomy

    NARCIS (Netherlands)

    Özdemir-van Brunschot, D.M.D.; Rottier, S.J.; Ouden, J.E. den; Jagt, M.F.P. van der; D'Ancona, F.C.H.; Kloke, H.J.; Vliet, D. van der; Schultze Kool, L.J.; Warle, M.C.

    2015-01-01

    BACKGROUND Implantation of a kidney with a short renal vein is technically more challenging and therefore prone for technique-related complications. It remains unclear whether pre-operative computed tomography angiography (CTA), to assess vascular anatomy of the donor kidney, can be used to predict

  13. Preoperative computed tomography and scintigraphy to facilitate the detection of accessory spleen in patients with hematologic disorders

    International Nuclear Information System (INIS)

    Koyanagi, Nobuhiro; Kanematsu, Takashi; Sugimachi, Keizo

    1988-01-01

    Accessory spleens of 1.5 cm in size were preoperatively identified by the combined use of computerized tomography and splenic scintigraphy in two patients with hematologic diseases. After the accessory spleen had been removed from the first patient, who had persistent hereditary spherocytosis and had undergone a splenectomy 15 months before, a postoperative decrease in hyperbilirubinemia was noted. In the other patient who had idiopathic thrombocytopenic purpura, a successful accessory splenectomy was done at the same time as her splenectomy, and was followed by 6 months' complete remission. These events indicate that preoperative investigations using computerized tomography and scintigraphy are indispensable for ruling out an accessory spleen in those patients for whom splenectomy needs to be done in order to alleviate hematologic disorders. (author)

  14. Computed tomography of juvenile nasopharyngeal angiofibroma

    Energy Technology Data Exchange (ETDEWEB)

    Park, Cheong Hee; Yoo, Shi Joon; Lee, Yul; Chang, Kee Hyun; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1985-02-15

    It is well known that computed tomography (CT) is useful in detecting accurately the location, extent, erosion and relationship of angiofibroma to surrounding structures such as pterygopalation fossa. It is well known that computed tomography (CT) is useful in detecting accurately the location, sphenoid sinus, and etc. CT of 20 patients with juvenile angiofibroma, which were examined for 5 yeas from February, 1979 to May, 1984 at Department of Radiology, Seoul National University Hospital, were retrospectively analyzed. The results were as follows: 1. All 20 patients of juvenile angiofibroma had tumors in nasopharynx and posterior nasal cavity showing homogeneously dense-enhancing soft tissue mass on CT. There was extension of the tumor from nasopharynx and posterior nasal cavity into paranasal sinus (60%, 12/20), pterygopalatine fossa (55%, 11/20), infratemporal fossa (30%, 6/20), posterior orbit (10%, 2/20) and cranial cavity (15%, 3/20). 2. Angiogrpahy usually adds little diagnostic information, but is still needed to identify the precise source of blood supply to the tumor, and to perform the pre-operative embolization. The use of CT has deferred angiography until just before surgery, permitting embolization at optimal time. 3. CT is almost always necessary to reveal accurately the full extent of the tumor, especially intracranial space in the axial and coronal planes with contrast enhancement. CT is useful both in diagnosis as a guide to angiography and in planning the adequate therapy of juvenile angiofibroma.

  15. Estimation of the supplementary axial wall stress generated at peak flow by an arterial stenosis

    International Nuclear Information System (INIS)

    Doriot, Pierre-Andre

    2003-01-01

    Mechanical stresses in arterial walls are known to be implicated in the development of atherosclerosis. While shear stress and circumferential stress have received a lot of attention, axial stress has not. Yet, stenoses can be intuitively expected to produce a supplementary axial stress during flow systole in the region immediately proximal to the constriction cone. In this paper, a model for the estimation of this effect is presented, and ten numerical examples are computed. These examples show that the cyclic increase in axial stress can be quite considerable in severe stenoses (typically 120% or more of the normal stress value). This result is in best agreement with the known mechanical or morphological risk factors of stenosis progression and restenosis (hypertension, elevated pulse pressure, degree of stenosis, stenosis geometry, residual stenosis, etc). The supplementary axial stress generated by a stenosis might create the damages in the endothelium and in the elastic membranes which potentiate the action of the other risk factors (hyperlipidaemia, diabetes, etc). It could thus be an important cause of stenosis progression and of restenosis

  16. CFD Numerical Simulation of the Complex Turbulent Flow Field in an Axial-Flow Water Pump

    Directory of Open Access Journals (Sweden)

    Wan-You Li

    2014-09-01

    Full Text Available Further optimal design of an axial-flow water pump calls for a thorough recognition of the characteristics of the complex turbulent flow field in the pump, which is however extremely difficult to be measured using the up-to-date experimental techniques. In this study, a numerical simulation procedure based on computational fluid dynamics (CFD was elaborated in order to obtain the fully three-dimensional unsteady turbulent flow field in an axial-flow water pump. The shear stress transport (SST k-ω model was employed in the CFD calculation to study the unsteady internal flow of the axial-flow pump. Upon the numerical simulation results, the characteristics of the velocity field and pressure field inside the impeller region were discussed in detail. The established model procedure in this study may provide guidance to the numerical simulations of turbomachines during the design phase or the investigation of flow and pressure field characteristics and performance. The presented information can be of reference value in further optimal design of the axial-flow pump.

  17. Estimation of the supplementary axial wall stress generated at peak flow by an arterial stenosis

    Science.gov (United States)

    Doriot, Pierre-André

    2003-01-01

    Mechanical stresses in arterial walls are known to be implicated in the development of atherosclerosis. While shear stress and circumferential stress have received a lot of attention, axial stress has not. Yet, stenoses can be intuitively expected to produce a supplementary axial stress during flow systole in the region immediately proximal to the constriction cone. In this paper, a model for the estimation of this effect is presented, and ten numerical examples are computed. These examples show that the cyclic increase in axial stress can be quite considerable in severe stenoses (typically 120% or more of the normal stress value). This result is in best agreement with the known mechanical or morphological risk factors of stenosis progression and restenosis (hypertension, elevated pulse pressure, degree of stenosis, stenosis geometry, residual stenosis, etc). The supplementary axial stress generated by a stenosis might create the damages in the endothelium and in the elastic membranes which potentiate the action of the other risk factors (hyperlipidaemia, diabetes, etc). It could thus be an important cause of stenosis progression and of restenosis.

  18. Pure ground glass nodular adenocarcinomas: Are preoperative positron emission tomography/computed tomography and brain magnetic resonance imaging useful or necessary?

    Science.gov (United States)

    Cho, Hyoun; Lee, Ho Yun; Kim, Jhingook; Kim, Hong Kwan; Choi, Joon Young; Um, Sang-Won; Lee, Kyung Soo

    2015-09-01

    The utility of (18)F-Fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) scanning and brain magnetic resonance imaging (MRI) as a staging workup for lung adenocarcinoma manifesting as pure ground glass opacity (GGO) is unknown. The purpose of this study was to determine the utility of these 2 tests for preoperative staging of pure GGO nodular lung adenocarcinoma. The study included 164 patients (male:female, 73:91; mean age, 62 years) with pure GGO nodular lung adenocarcinoma who underwent PET/CT (in 136 patients) and/or brain MRI (in 109 patients) before surgery. Pathologic N staging and dedicated standard imaging or follow-up imaging findings for M staging were used as reference standards. The median follow-up time was 47.9 months. On PET/CT scan, abnormal FDG uptake of lymph nodes was found in 2 of 136 patients (1.5%); both were negative on final pathology. Abnormal FDG uptake of the liver was detected in 1 patient, which was also confirmed to be negative by dedicated abdominal CT. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of PET/CT in detecting metastases were not applicable, 98% (95% confidence interval [CI], 94%-100%), 0% (95% CI, 0%-71%), 100% (95% CI, 97%-100%), and 98% (95% CI, 94%-100%), respectively. No brain metastasis was found in preoperative brain MRI of 109 patients. Of 109 patients, 1 (0.9%) developed brain metastasis 30 months after surgical resection. PET/CT and brain MRI is not necessary in the staging of pure GGO nodular lung adenocarcinoma. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  19. A novel diagnostic method (spectral computed tomography of sacroiliac joints) for axial spondyloarthritis.

    Science.gov (United States)

    Zhang, Ping; Yu, Kai Hu; Guo, Rui Min; Ran, Jun; Liu, Yao; Morelli, John; Runge, Val M; Li, Xiao Ming

    2016-08-01

    To evaluate the diagnostic value of spectral computed tomography (CT) of sacroiliac joints for axial spondyloarthritis (SpA). We retrospectively analyzed the records of 125 patients with low back pain (LBP) suspected of having SpA. Each patient underwent sacroiliac joint spectral CT examination. Water- and calcium-based material decomposition images were reconstructed. After 3-6 months of follow-up, 76 were diagnosed with SpA, and the remaining 49 patients were diagnosed with nonspecific LBP (nLBP). The slope of sacroiliac bone marrow HU (Hounsfield unit) curve (λHU), CT value, and bone marrow to normal muscle ratios of water and calcium concentrations in the ilium and sacrum were calculated and compared between nLBP and SpA patients. The iliac λHU was 8.26 ± 3.91 for nLBP and 9.81 ± 4.92 for SpA. The mean iliac ratios of water and calcium concentrations were 1.04 ± 0.03 and 21.67 ± 4.40, respectively, for nLBP, and 1.07 ± 0.04 and 111.5 ± 358.98, respectively, for SpA. The mean iliac CT values were 311.12 ± 86.52 HU for nLBP and 423.97 ± 127.51 HU for SpA. There were statistically significant differences in iliac ratios of water and calcium concentrations, CT value, and λHU between nLBP and SpA patients (p sacroiliac joints of SpA patients. Copyright © 2015. Published by Elsevier B.V.

  20. Yang-Mills theories in axial and light-cone gauges, analytic regularization and Ward identities

    International Nuclear Information System (INIS)

    Lee, H.C.

    1984-12-01

    The application of the principles of generalization and analytic continuation to the regularization of divergent Feynman integrals is discussed. The technique, or analytic regularization, which is a generalization of dimensional regularization, is used to derive analytic representations for two classes of massless two-point integrals. The first class is based on the principal-value prescription and includes integrals encountered in quantum field theories in the ghost-free axial gauge (n.A=0), reducing in a special case to integrals in the light-cone gauge (n.A=0,n 2 =0). The second class is based on the Mandelstam prescription devised espcially for the light-cone gauge. For some light-cone gauge integrals the two representations are not equivalent. Both classes include as a subclass integrals in the Lorentz covariant 'zeta-gauges'. The representations are used to compute one-loop corrections to the self-energy and the three-vertex in Yang-Mills theories in the axial and light-cone gauges, showing that the two- and three-point Ward identities are satisfied; to illustrate that ultraviolet and infrared singularities, indistinguishable in dimensional regularization, can be separated analytically; and to show that certain tadpole integrals vanish because of an exact cancellation between ultraviolet and infrared singularities. In the axial gauge, the wavefunction and vertex renormalization constants, Z 3 and Z 1 , are identical, so that the β-function can be directly derived from Z 3 the result being the same as that computed in the covariant zeta-gauges. Preliminary results suggest that the light-cone gauge in the Mandelstam prescription, but not in the principal value prescription, has the same renormalization property of the axial gauge

  1. Preoperative staging of rectal cancer by magnetic resonance imaging (MRI) and computed tomography (CT)

    International Nuclear Information System (INIS)

    Itabashi, Michiaki; Kameoka, Shingo; Nakajima, Kiyotaka; Izumi, Kiminari; Miyazaki, Kaname; Hamano, Kyoichi; Kouno, Atsushi

    1991-01-01

    To clarify the usefulness and limitations of CT and MRI in preoperative assessment of the wall invasion of rectal cancer, we compared the results of CT and MRI with the histopathological findings, classifying tumors by the region and site in 34 patients with rectal cancer. Subjects were patients preoperatively examined by MRI and CT. Overall, the percent of cases with the extent of invasion accurately assessed by MRI was 88.2%, and that by CT was 64.7%. In all instances of wrong assessment, the extent of invasion was overestimated. The accurate assessment rate was significantly higher for MRI than for CT. After classification by the region, the accurate assessment rate at Rs was low as 50% for both MRI and CT because slices were not perpendicular to the tumor. The accurate assessment rate was 100% for MRI and 82% for CT at Ra, and respectively 94% and 59% at Rb. The majority of tumors at Ra or Rb centering on the lateral wall of the rectum were accurately assessed either by MRI or CT. With tumors at Ra or Rb (particularly Rb) centering on the anterior or posterior wall, CT frequently failed to identify the extent of invasion accurately, so that MRI seemed more suitable for these tumors. (author)

  2. Pre-operative evaluation for thorax surgery

    International Nuclear Information System (INIS)

    Silva Luis, Saenz; Morales, Oscar Alberto

    2002-01-01

    A pre-operative analysis of the function of the breathing system is made in the patient that will be taken to thorax surgery. The paper includes risk factors, pre-operative clinical evaluation and of breathing and cardiovascular system

  3. Assessing the registration of CT-scan data to intraoperative x rays by fusing x rays and preoperative information

    Science.gov (United States)

    Gueziec, Andre P.

    1999-05-01

    This paper addresses a key issue of providing clinicians with visual feedback to validate a computer-generated registration of pre-operative and intra-operative data. With this feedback information, the clinician may decide to proceed with a computer-assisted intervention, revert to a manual intervention, or potentially provide information to the computer system to improve the registration. The paper focuses on total hip replacement (THR) surgery, but similar techniques could be applied to other types of interventions or therapy, including orthopedics, neurosurgery, and radiation therapy. Pre-operative CT data is used to plane the surgery (select an implant type, size and precise position), and is registered to intra-operative X-ray images, allowing to execute the plan: mill a cavity with the implant's shape. (Intra-operative X-ray images must be calibrated with respect to the surgical device executing the plan). One novel technique presented in this paper consists of simulating a post-operative X-ray image of the tissue of interest before doing the procedure, by projecting the registered implant onto an intra-operative X- ray image (corrected for distortion or not), providing clinicians with familiar and easy to interpret images. As an additional benefit, this method provides new means for comparing various strategies for registering pre-operative data to the physical space of the operating room.

  4. Preoperative staging of lung cancer with combined PET-CT

    DEFF Research Database (Denmark)

    Fischer, Barbara; Lassen, Ulrik; Mortensen, Jann

    2009-01-01

    BACKGROUND: Fast and accurate staging is essential for choosing treatment for non-small-cell lung cancer (NSCLC). The purpose of this randomized study was to evaluate the clinical effect of combined positron-emission tomography and computed tomography (PET-CT) on preoperative staging of NSCLC...... one of the following: a thoracotomy with the finding of pathologically confirmed mediastinal lymph-node involvement (stage IIIA [N2]), stage IIIB or stage IV disease, or a benign lung lesion; an exploratory thoracotomy; or a thoracotomy in a patient who had recurrent disease or death from any cause...

  5. Preoperative bone scans

    International Nuclear Information System (INIS)

    Charkes, N.D.; Malmud, L.S.; Caswell, T.; Goldman, L.; Hall, J.; Lauby, V.; Lightfoot, W.; Maier, W.; Rosemond, G.

    1975-01-01

    Strontium nitrate Sr-87m bone scans were made preoperatively in a group of women with suspected breast cancer, 35 of whom subsequently underwent radical mastectomy. In 3 of the 35 (9 percent), the scans were abnormal despite the absence of clinical or roentgenographic evidence of metastatic disease. All three patients had extensive axillary lymph node involvement by tumor, and went on to have additional bone metastases, from which one died. Roentgenograms failed to detect the metastases in all three. Occult bone metastases account in part for the failure of radical mastectomy to cure some patients with breast cancer. It is recommended that all candidates for radical mastectomy have a preoperative bone scan. (U.S.)

  6. Immediate preoperative enteral nutrition (preoperative enteral nutrition

    Directory of Open Access Journals (Sweden)

    Lađević Nebojša

    2017-01-01

    Full Text Available Nutritional support of surgical patients is a necessary part of the treatment. It alone cannot cure the disease but it significantly affects the recovery of patients and supports surgical interventions. Patients in malnutrition have shown to have significantly more postoperative infectious and non-infectious complications. This significantly prolongs treatment time and increases costs. However, there is one fact that cannot be expressed in money, which is the patient's impression of the surgical intervention. Adequate preoperative patient support, based on the intake of liquid nutritive solutions, reduces preoperative stress and deflects the metabolic response. Now, it is recommended for adults and children older than one year to drink clear liquid up to 2 hours before induction in anesthesia. Appropriate enteral nutrition has a significant place in the postoperative recovery of patients. Enteral nutrition is reducing complications, mainly infectious complications because the function of the digestive system as one large immune system is preserved. Perioperative enteral nutrition is a necessary part of the modern treatment of surgical patients. In addition to the significant effect on the occurrence of postoperative complications, it is also important that this type of diet improves the psychological status of patients.

  7. Preoperative patient education: evaluating postoperative patient outcomes.

    Science.gov (United States)

    Meeker, B J

    1994-04-01

    Preoperative teaching is an important part of patient care and can prevent complications, as well as promote patient fulfillment during hospitalization. A study was conducted at Alton Ochsner Medical Foundation in New Orleans, LA, in 1989, to determine the impact of a preoperative teaching program on the incidence of postoperative atelectasis and patient satisfaction. Results showed no significant difference of postoperative complications and patient gratification after participating in a structured preoperative teaching program. As part of this study, it was identified that a patient evaluation tool for a preoperative teaching class needed to be developed. The phases of this process are explained in the following article.

  8. Preoperative diagnosis and surgical strategy in congenital auditory ossicular malformation of 26 ears

    International Nuclear Information System (INIS)

    Kanazawa, Yuji; Naito, Yasushi; Shinohara, Shogo; Fujiwara, Keizo; Kikuchi, Masahiro; Yamazaki, Hiroshi; Kurihara, Risa; Kishimoto, Ippei

    2012-01-01

    We retrospectively analyzed 26 ears of 21 subjects having auditory ossicular malformation and who had undergone auditory reconstruction between April 2004 and December 2010 at our clinic. We checked preoperative condition, pathological classification, surgical procedure, and hearing improvement. We could predict pathological conditions precisely from preoperative computed tomography (CT), including incudostapedial disconnection (9/12, 75%) and malleus and/or incus fixation (7/12, 58%), which tended to be present in external ear malformation, and stapes footplate fixation (0/12, 0%). We could not, however, predict complex malformation (0/8, 0%). Overall success was 90% (18/20) in the 20 ears observed for at least 1 year. In the 2 ears without improved hearing, the first had congenital cholesteatoma and no stapes superstructure, was treated with type IV tympanoplasty. The second had malleus, incus, and stapes fixation and discontinuity between the incus and stapes, and was treated with type III tympanoplasty and stapes mobilization. Preoperative diagnosis is difficult in mixed congenital auditory ossicular malformation, especially stapes footplate fixation, possibly requiring unexpected procedures, with a poor hearing outcome. Preoperative status must thus be evaluated precisely using hearing, tympanometry, acoustic reflex test, and CT. Temporal bone CT and external ear findings are useful in diagnosing middle-ear malformation. Subjects' informed consent should also be obtained due to the possible need for changing procedure based on findings during surgery. (author)

  9. Interventions for preoperative smoking cessation

    DEFF Research Database (Denmark)

    Thomsen, Thordis; Villebro, Nete; Møller, Ann Merete

    2014-01-01

    BACKGROUND: Smokers have a substantially increased risk of postoperative complications. Preoperative smoking intervention may be effective in decreasing this incidence, and surgery may constitute a unique opportunity for smoking cessation interventions. OBJECTIVES: The objectives of this review...... are to assess the effect of preoperative smoking intervention on smoking cessation at the time of surgery and 12 months postoperatively, and on the incidence of postoperative complications. SEARCH METHODS: We searched the Cochrane Tobacco Addiction Group Specialized Register in January 2014. SELECTION CRITERIA......: Randomized controlled trials that recruited people who smoked prior to surgery, offered a smoking cessation intervention, and measured preoperative and long-term abstinence from smoking or the incidence of postoperative complications or both outcomes. DATA COLLECTION AND ANALYSIS: The review authors...

  10. The value of computed tomography-urography in predicting the ...

    African Journals Online (AJOL)

    Background The natural course of pelviureteric junction (PUJ) obstruction is variable. Of those who require surgical intervention, there is no definite reliable preoperative predictor of the likely postoperative outcome. We evaluated the value of preoperative computed tomography (CT)-urography in predicting the ...

  11. Multislice computed tomography coronary angiography

    NARCIS (Netherlands)

    F. Cademartiri (Filippo)

    2005-01-01

    markdownabstract__Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axial Tomography). Tomography is from the Greek word "tomos" meaning "slice" or "section" and "graphia" meaning "describing". CT was invented in 1972 by British engineer Godfrey Hounsfield

  12. Vector and axial constants of the baryon decuplet

    International Nuclear Information System (INIS)

    Belyaev, V.M.; Blok, B.Y.; Kogan, Y.I.

    1985-01-01

    On the basis of the QCD sum rules for the polarization operator in external axial and vector fields we determine the vector and axial transition constants in the 3/2 + baryon decuplet. We show that the renormalization of the axial constant is due to the interaction of the external axial field with the quark condensate

  13. Axial gap rotating electrical machine

    Science.gov (United States)

    None

    2016-02-23

    Direct drive rotating electrical machines with axial air gaps are disclosed. In these machines, a rotor ring and stator ring define an axial air gap between them. Sets of gap-maintaining rolling supports bear between the rotor ring and the stator ring at their peripheries to maintain the axial air gap. Also disclosed are wind turbines using these generators, and structures and methods for mounting direct drive rotating electrical generators to the hubs of wind turbines. In particular, the rotor ring of the generator may be carried directly by the hub of a wind turbine to rotate relative to a shaft without being mounted directly to the shaft.

  14. Study of axial magnetic effect

    Energy Technology Data Exchange (ETDEWEB)

    Braguta, Victor [IHEP, Protvino, Moscow region, 142284 Russia ITEP, B. Cheremushkinskaya street 25, Moscow, 117218 (Russian Federation); School of Biomedicine, Far Eastern Federal University, Ajax 10 Building 25, Russian island, Vladivostok, 690922 (Russian Federation); Chernodub, M. N. [CNRS, Laboratoire de Mathématiques et Physique Théorique, Université François-Rabelais Tours, Fédération Denis Poisson, Parc de Grandmont, 37200 Tours, France Department of Physics and Astronomy, University of Gent, Krijgslaan 281, S9, B-9000 Gent (Belgium); School of Biomedicine, Far Eastern Federal University, Ajax 10 Building 25, Russian island, Vladivostok, 690922 (Russian Federation); Goy, V. A. [School of Natural Sciences, Far Eastern Federal University, Sukhanova street 8, Vladivostok, 690950 (Russian Federation); Landsteiner, K. [Instituto de Física Teórica UAM/CSIC, C/ Nicolás Cabrera 13-15, Universidad Autónoma de Madrid, Cantoblanco, 28049 Madrid (Spain); Molochkov, A. V. [School of Biomedicine, Far Eastern Federal University, Ajax 10 Building 25, Russian island, Vladivostok, 690922 (Russian Federation); Ulybyshev, M. [ITEP, B. Cheremushkinskaya street 25, Moscow, 117218 Russia Institute for Theoretical Problems of Microphysics, Moscow State University, Moscow, 119899 (Russian Federation)

    2016-01-22

    The Axial Magnetic Effect manifests itself as an equilibrium energy flow of massless fermions induced by the axial (chiral) magnetic field. Here we study the Axial Magnetic Effect in the quenched SU(2) lattice gauge theory with massless overlap fermions at finite temperature. We numerically observe that in the low-temperature hadron phase the effect is absent due to the quark confinement. In the high-temperature deconfinement phase the energy flow is an increasing function of the temperature which reaches the predicted asymptotic T{sup 2} behavior at high temperatures. We find, however, that energy flow is about one order of magnitude lower compared to a theoretical prediction.

  15. Can axial-based nodal size criteria be used in other imaging planes to accurately determine "enlarged" head and neck lymph nodes?

    Science.gov (United States)

    Bartlett, Eric S; Walters, Thomas D; Yu, Eugene

    2013-01-01

    Objective. We evaluate if axial-based lymph node size criteria can be applied to coronal and sagittal planes. Methods. Fifty pretreatment computed tomographic (CT) neck exams were evaluated in patients with head and neck squamous cell carcinoma (SCCa) and neck lymphadenopathy. Axial-based size criteria were applied to all 3 imaging planes, measured, and classified as "enlarged" if equal to or exceeding size criteria. Results. 222 lymph nodes were "enlarged" in one imaging plane; however, 53.2% (118/222) of these were "enlarged" in all 3 planes. Classification concordance between axial versus coronal/sagittal planes was poor (kappa = -0.09 and -0.07, resp., P planes. Conclusion. Classification of "enlarged" lymph nodes differs between axial versus coronal/sagittal imaging planes when axial-based nodal size criteria are applied independently to all three imaging planes, and exclusively used without other morphologic nodal data.

  16. Preoperative Smoking Status and Postoperative Complications

    DEFF Research Database (Denmark)

    Pedersen, Marie Grønkjær; Eliasen, Marie; Skov-Ettrup, Lise Skrubbeltrang

    2014-01-01

    To systematically review and summarize the evidence of an association between preoperative smoking status and postoperative complications elaborated on complication type.......To systematically review and summarize the evidence of an association between preoperative smoking status and postoperative complications elaborated on complication type....

  17. Preoperative assessment of vascular anatomy by multidetector computed tomography before laparoscopic colectomy for transverse colon cancer: report of a case.

    Science.gov (United States)

    Kawamoto, Aya; Inoue, Yasuhiro; Okigami, Masato; Yasuda, Hiromi; Okugawa, Yoshinaga; Hiro, Junichiro; Toiyama, Yuji; Tanaka, Koji; Uchida, Keiichi; Mohri, Yasuhiko; Kusunoki, Masato

    2015-02-01

    Although the safety of laparoscopic surgery for colon cancer has been reported in many randomized controlled trials, concerns about the difficulty of surgery for transverse colon cancer has not been fully resolved, mainly because of the variation in the vascular anatomy of mesenteric vessels, which leads to difficulty in determining the optimal operative procedure and the extent of lymph node dissection. We present the case of a patient with transverse colon cancer who underwent laparoscopic surgery after preoperative assessment using a combination of endoscopic clipping and three-dimensional computed tomography angiography (3DCTA). A 68-year-old man was diagnosed with transverse colon cancer, and laparoscopic surgery has been planned. 3DCTA showed right-middle and left-middle colic arteries arising independently from the superior mesenteric artery. The relationship between the clip and vessels showed that the right-middle colic artery was the feeding artery of the tumor. Operative findings were consistent with 3DCTA findings, and transverse colectomy with lymph node dissection was successfully performed.

  18. Electric machines with axial magnetic flux

    Science.gov (United States)

    Nuca, I.; Ambros, T.; Burduniuc, M.; Deaconu, S. I.; Turcanu, A.

    2018-01-01

    The paper contains information on the performance of axial machines compared to cylindrical ones. At the same time, various constructive schemes of synchronous electromechanical converters with permanent magnets and asynchronous with short-circuited rotor are presented. In the developed constructions, the aim is to maximize the usage of the material of the stator windings. The design elements of the axial machine magnetic system are presented. The FEMM application depicted the array of the magnetic field of an axial machine.

  19. Intrinsic carpal ligaments on MR and multidetector CT arthrography: comparison of axial and axial oblique planes

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ryan K.L.; Griffith, James F.; Ng, Alex W.H.; Law, Eric K.C. [The Chinese University of Hong Kong, Department of Imaging and Interventional Radiology, Prince Of Wales Hospital, Hong Kong (China); Tse, W.L.; Wong, Clara W.Y.; Ho, P.C. [The Chinese University of Hong Kong, Department of Orthopedics and Traumatology, Prince Of Wales Hospital, Hong Kong (China)

    2017-03-15

    To compare axial and oblique axial planes on MR arthrography (MRA) and multidetector CT arthrography (CTA) to evaluate dorsal and volar parts of scapholunate (SLIL) and lunotriquetral interosseous (LTIL) ligaments. Nine cadaveric wrists of five male subjects were studied. The visibility of dorsal and volar parts of the SLIL and LTIL was graded semi-quantitatively (good, intermediate, poor) on MRA and CTA. The presence of a ligament tear was determined on arthrosocopy and sensitivity, specificity and accuracy of tear detection were calculated. Oblique axial imaging was particularly useful for delineating dorsal and volar parts of the LTIL on MRA with overall 'good' visibility increased from 11 % to 78 %. The accuracy of MRA and CTA in revealing SLIL and LTIL tear was higher using the oblique axial plane. The overall accuracy for detecting SLIL tear on CTA improved from 94 % to 100 % and from 89 % to 94 % on MRA; the overall accuracy of detecting LTIL tear on CTA improved from 89 % to 100 % and from 72 % to 89 % on MRA Oblique axial imaging during CT and MR arthrography improves detection of tears in the dorsal and volar parts of both SLIL and LTIL. (orig.)

  20. [Axial computer tomography of the neurocranium (author's transl)].

    Science.gov (United States)

    Stöppler, L

    1977-05-27

    Computer tomography (CT), a new radiographic examination technique, is very highly efficient, for it has high informative content with little stress for the patient. In contrast to the conventional X-ray technology, CT succeeds, by direct presentation of the structure of the soft parts, in obtaining information which comes close to that of macroscopic neuropathology. The capacity and limitations of the method at the present stage of development are reported. Computer tomography cannot displace conventional neuroradiological methods of investigation, although it is rightly presented as a screening method and helps towards selective use. Indications, technical integration and handling of CT are prerequisites for the exhaustive benefit of the excellent new technique.

  1. Radial and axial compression of pure electron

    International Nuclear Information System (INIS)

    Park, Y.; Soga, Y.; Mihara, Y.; Takeda, M.; Kamada, K.

    2013-01-01

    Experimental studies are carried out on compression of the density distribution of a pure electron plasma confined in a Malmberg-Penning Trap in Kanazawa University. More than six times increase of the on-axis density is observed under application of an external rotating electric field that couples to low-order Trivelpiece-Gould modes. Axial compression of the density distribution with the axial length of a factor of two is achieved by controlling the confining potential at both ends of the plasma. Substantial increase of the axial kinetic energy is observed during the axial compression. (author)

  2. View of the Axial Field Spectrometer

    CERN Multimedia

    1980-01-01

    The Axial Field Spectrometer, with the vertical uranium/scintillator calorimeter and the central drift chamber retracted for service. One coil of the Open Axial Field Magnet is just visible to the right.

  3. Diagnostic value of multidetector row CT in rectal cancer staging: comparison of multiplanar and axial images with histopathology

    International Nuclear Information System (INIS)

    Sinha, R.; Verma, R.; Rajesh, A.; Richards, C.J.

    2006-01-01

    Aim: Although magnetic resonance (MR) imaging is widely used for rectal cancer staging, many centres in the UK perform computed tomography (CT) for staging rectal cancer at present. Furthermore in a small proportion of cases contraindications to MR imaging may lead to staging using CT. The purpose of this study was to evaluate the accuracy of current generation multidetector row CT (MDCT) in local staging of rectal cancer. In particular the accuracy of multiplanar (MPR) versus axial images in the staging of rectal cancer was assessed. Material and methods: Sixty-nine consecutive patients were identified who had undergone staging of rectal cancer on CT. The imaging data were reviewed as axial images and then as MPR images (coronal and sagittal) perpendicular and parallel to the tumour axis. CT staging on axial and MPR images was then compared to histopathological staging. Results: MPR images detected more T4 and T3 stage tumours than axial images alone. The overall accuracy of T-staging on MPR images was 87.1% versus 73.0% for axial images alone. The overall accuracy of N staging on MPR versus axial images was 84.8% versus 70.7%. There was a statistically significant difference in the staging of T3 tumours between MPR and axial images (p < 0.001). Conclusion: Multidetector row CT has high accuracy for local staging of rectal cancer. Addition of MPR images to standard axial images provides higher accuracy rates for T and N staging of rectal cancer than axial images alone

  4. Axial SPN and radial MOC coupled whole core transport calculation

    International Nuclear Information System (INIS)

    Cho, Jin-Young; Kim, Kang-Seog; Lee, Chung-Chan; Zee, Sung-Quun; Joo, Han-Gyu

    2007-01-01

    The Simplified P N (SP N ) method is applied to the axial solution of the two-dimensional (2-D) method of characteristics (MOC) solution based whole core transport calculation. A sub-plane scheme and the nodal expansion method (NEM) are employed for the solution of the one-dimensional (1-D) SP N equations involving a radial transverse leakage. The SP N solver replaces the axial diffusion solver of the DeCART direct whole core transport code to provide more accurate, transport theory based axial solutions. In the sub-plane scheme, the radial equivalent homogenization parameters generated by the local MOC for a thick plane are assigned to the multiple finer planes in the subsequent global three-dimensional (3-D) coarse mesh finite difference (CMFD) calculation in which the NEM is employed for the axial solution. The sub-plane scheme induces a much less nodal error while having little impact on the axial leakage representation of the radial MOC calculation. The performance of the sub-plane scheme and SP N nodal transport solver is examined by solving a set of demonstrative problems and the C5G7MOX 3-D extension benchmark problems. It is shown in the demonstrative problems that the nodal error reaching upto 1,400 pcm in a rodded case is reduced to 10 pcm by introducing 10 sub-planes per MOC plane and the transport error is reduced from about 150 pcm to 10 pcm by using SP 3 . Also it is observed, in the C5G7MOX rodded configuration B problem, that the eigenvalues and pin power errors of 180 pcm and 2.2% of the 10 sub-planes diffusion case are reduced to 40 pcm and 1.4%, respectively, for SP 3 with only about a 15% increase in the computing time. It is shown that the SP 5 case gives very similar results to the SP 3 case. (author)

  5. Preoperative stoma site marking in the general surgery population.

    Science.gov (United States)

    Zimnicki, Katherine M

    2013-01-01

    Preoperative teaching and stoma site marking are supported by research and professional organizations as interventions that can reduce the incidence of problematic stomas and improve patient outcomes. This study investigated the translation of this research into practice in the acute care surgery population. A retrospective chart review using convenience sampling was conducted at a large urban hospital in the Midwestern United States. Thirty patients underwent a surgical procedure that resulted in the creation of a fecal ostomy over a 5-month period. Descriptive statistical analysis examined the reason for surgery, preoperative length of stay (LOS), the percentage of patients who received preoperative teaching and stoma marking and the relationship between preoperative LOS and the use of preoperative teaching and stoma marking. Twenty-one of 30 patients were admitted to hospital 24 hours or more before surgery. No participants were admitted urgently. Three (14%) of those admitted for more than 24 hours received preoperative marking or teaching. There was no significant relationship between preoperative LOS and preoperative teaching and stoma marking. The opportunity exists to promote successful adaptation in this surgical population through the implementation of the evidence-based interventions of preoperative teaching and stoma marking. Additional study is needed to determine barriers to their use as well as to develop effective implementation strategies.

  6. Temporal and Spatial Variability in the Geochemistry of Axial and CoAxial Segment Lavas and their Mantle Sources

    Science.gov (United States)

    Smith, M. C.; Perfit, M. R.; Davis, C.; Kamenov, G. D.

    2011-12-01

    Three spatially related volcanic eruptions along the CoAxial Segment of the Juan de Fuca Ridge (JdFR) have documented emplacements between 1981 and 1993. Two of the historic flows outcrop at the "Flow Site" and were emplaced within less than 12 years and 500 m from one another. The third was emplaced at the "Floc Site" to the south in the 1980s. Previous studies have documented that CoAxial lavas are among the most incompatible element and isotopically depleted lavas along the entire JdFR, whereas the Axial Seamount segment immediately south of CoAxial has erupted the most chemically enriched lavas south of the Endeavor Segment. Geochemical studies have shown little temporal change in the chemistry of recent Axial Seamount eruptives, whereas CoAxial lavas exhibit distinct chemical differences over short time periods. Significant chemical differences observed among depleted CoAxial lavas emplaced close to one another in space and time are in marked contrast to the relatively constant chemical characteristics of enriched lavas erupted at the magmatically more robust Axial segment only 10's of kilometers to the south and west. New trace element and isotopic (Sr, Nd, Pb) geochemical analyses of historic and older CoAxial lavas have resulted in better documentation of interflow and intraflow chemical variation providing an improved understanding of spatial/temporal chemical variability in lavas, and further insight into JdFR magmatic processes. Modeling of major and trace element abundances suggest that the observed intraflow chemical variation within CoAxial lavas is largely due to shallow-level fractional crystallization but that a single fractional crystallization model cannot account for all interflow chemical variation. In fact, elemental and isotopic data require different parental magmas for each of the three recent CoAxial Segment lava flows suggesting very short-term differences or changes in the chemical character of the mantle source region. In particular

  7. The Added Diagnostic Value of 18F-Fluorodihydroxyphenylalanine PET/CT in the Preoperative Work-Up of Small Bowel Neuroendocrine Tumors.

    Science.gov (United States)

    Addeo, Pietro; Poncet, Gilles; Goichot, Bernard; Leclerc, Loic; Brigand, Cécile; Mutter, Didier; Romain, Benoit; Namer, Izzie-Jacques; Bachellier, Philippe; Imperiale, Alessio

    2018-04-01

    The precise localization of the primary tumor and/or the identification of multiple primary tumors improves the preoperative work-up in patients with small bowel (SB) neuroendocrine tumor (NET). The present study assesses the diagnostic value of 18 F-fluorodihydroxyphenylalanine ( 18 F-FDOPA) positron emission tomography/computed tomography (PET/CT) during the preoperative wok-up of SB NETs. Between January 2010 and June 2017, all consecutive patients with SB NETs undergoing preoperative 18 F-FDOPA PET/CT and successive resection were analyzed. Preoperative work-up included computed tomography (CT), somatostatin receptor scintigraphy (SRS), and 18 F-FDOPA PET/CT. Sensitivity and accuracy ratio for primary and multiple tumor detection were compared with data from surgery and pathology. There were 17 consecutive patients with SB NETs undergoing surgery. Nine patients (53%) had multiple tumors, 15 (88%) metastatic lymph nodes, 3 (18%) peritoneal carcinomatosis, and 9 patients (53%) liver metastases. A total of 70 SB NETs were found by pathology. Surgery identified the primary in 17/17 (100%) patients and recognized seven of 9 patients (78%) with multiple synchronous SB. Preoperatively, 18 F-FDOPA PET/CT displayed a statistically significant higher sensitivity for primary tumor localization (100 vs. 23.5 vs. 29.5%) and multiple tumor detection (78 vs. 22 vs. 11%) over SRS and CT. Compared with pathology, 18 F-FDOPA PET/CT displayed the highest accuracy ratio for number of tumor detected over CT and SRS (2.0 ± 2.2 vs. 0.4 ± 0.7 vs. 0.6 ± 1.5, p = 0.0003). 18 F-FDOPA PET/CT significantly increased the sensitivity and accuracy for primary and multiple SB NET identification. 18 F-FDOPA PET/CT should be included systematically in the preoperative work-up of SB NET.

  8. AP1000 passive core cooling system pre-operational tests procedure definition and simulation by means of Relap5 Mod. 3.3 computer code

    International Nuclear Information System (INIS)

    Lioce, D.; Asztalos, M.; Alemberti, A.; Barucca, L.; Frogheri, M.; Saiu, G.

    2012-01-01

    Highlights: ► Two AP1000 Core Make-up Tanks pre-operational tests procedures have been defined. ► The two tests have been simulated by means of the Relap5 computer code. ► Results show the tests can be successfully performed with the selected procedures. - Abstract: The AP1000 ® plant is an advanced Pressurized Water Reactor designed and developed by Westinghouse Electric Company which relies on passive safety systems for core cooling, containment isolation and containment cooling, and maintenance of main control room emergency habitability. The AP1000 design obtained the Design Certification by NRC in January 2006, as Appendix D of 10 CFR Part 52, and it is being built in two locations in China. The AP1000 plant will be the first commercial nuclear power plant to rely on completely passive safety systems for core cooling and its licensing process requires the proper operation of these systems to be demonstrated through some pre-operational tests to be conducted on the real plant. The overall objective of the test program is to demonstrate that the plant has been constructed as designed, that the systems perform consistently with the plant design, and that activities culminating in operation at full licensed power including initial fuel load, initial criticality, and power increase to full load are performed in a controlled and safe manner. Within this framework, Westinghouse Electric Company and its partner Ansaldo Nucleare S.p.A. have strictly collaborated, being Ansaldo Nucleare S.p.A. in charge of the simulation of some pre-operational tests and supporting Westinghouse in the definition of tests procedures. This paper summarizes the work performed at Ansaldo Nucleare S.p.A. in collaboration with Westinghouse Electric Company for the Core Makeup Tank (CMT) tests, i.e. the CMTs hot recirculation test and the CMTs draindown test. The test procedure for the two selected tests has been defined and, in order to perform the pre-operational tests simulations, a

  9. AP1000 passive core cooling system pre-operational tests procedure definition and simulation by means of Relap5 Mod. 3.3 computer code

    Energy Technology Data Exchange (ETDEWEB)

    Lioce, D., E-mail: donato.lioce@aen.ansaldo.it [Ansaldo Nucleare S.p.A., Corso F. M. Perrone 25, 16161, Genova (Italy); Asztalos, M., E-mail: asztalmj@westinghouse.com [Westinghouse Electric Company, Cranberry Twp, PA 16066 (United States); Alemberti, A., E-mail: alessandro.alemberti@aen.ansaldo.it [Ansaldo Nucleare S.p.A., Corso F. M. Perrone 25, 16161, Genova (Italy); Barucca, L. [Ansaldo Nucleare S.p.A., Corso F. M. Perrone 25, 16161, Genova (Italy); Frogheri, M., E-mail: monicalinda.frogheri@aen.ansaldo.it [Ansaldo Nucleare S.p.A., Corso F. M. Perrone 25, 16161, Genova (Italy); Saiu, G., E-mail: gianfranco.saiu@aen.ansaldo.it [Ansaldo Nucleare S.p.A., Corso F. M. Perrone 25, 16161, Genova (Italy)

    2012-09-15

    Highlights: Black-Right-Pointing-Pointer Two AP1000 Core Make-up Tanks pre-operational tests procedures have been defined. Black-Right-Pointing-Pointer The two tests have been simulated by means of the Relap5 computer code. Black-Right-Pointing-Pointer Results show the tests can be successfully performed with the selected procedures. - Abstract: The AP1000{sup Registered-Sign} plant is an advanced Pressurized Water Reactor designed and developed by Westinghouse Electric Company which relies on passive safety systems for core cooling, containment isolation and containment cooling, and maintenance of main control room emergency habitability. The AP1000 design obtained the Design Certification by NRC in January 2006, as Appendix D of 10 CFR Part 52, and it is being built in two locations in China. The AP1000 plant will be the first commercial nuclear power plant to rely on completely passive safety systems for core cooling and its licensing process requires the proper operation of these systems to be demonstrated through some pre-operational tests to be conducted on the real plant. The overall objective of the test program is to demonstrate that the plant has been constructed as designed, that the systems perform consistently with the plant design, and that activities culminating in operation at full licensed power including initial fuel load, initial criticality, and power increase to full load are performed in a controlled and safe manner. Within this framework, Westinghouse Electric Company and its partner Ansaldo Nucleare S.p.A. have strictly collaborated, being Ansaldo Nucleare S.p.A. in charge of the simulation of some pre-operational tests and supporting Westinghouse in the definition of tests procedures. This paper summarizes the work performed at Ansaldo Nucleare S.p.A. in collaboration with Westinghouse Electric Company for the Core Makeup Tank (CMT) tests, i.e. the CMTs hot recirculation test and the CMTs draindown test. The test procedure for the two

  10. Computational modeling of the axial-cylindrical inertial electrostatic confinement fusion neutron generator

    Science.gov (United States)

    Bromley, Blair Patrick

    2001-12-01

    The axial-cylindrical Inertial Electrostatic Confinement fusion neutron generator (IEC C-Device) is a high- voltage, low-pressure glow discharge device that produces neutrons from the deuterium-deuterium fusion reaction. Such a neutron source has potential applications for neutron activation analysis and capture therapies for cancer treatment. The IEC C-Device operating with deuterium fuel is modeled with the CHIMP computer code developed and written completely by the author to predict the fusion neutron generation rate and the plasma physics behavior using fundamental first principles. The CHIMP code is a time-dependent, spatially two-dimensional (r,z), particle-in-cell, Monte-Carlo-Collision (PIC-MCC) direct simulation model. The effects of secondary electron emission due to ion and electron impact on the metal electrodes and the glass walls and charge build-up on the glass wall are included. Either monatomic or molecular ions and electrons are modeled in a monatomic or molecular background neutral deuterium gas. CHIMP code predictions are compared against experimental results for the C-Device operating between 10 and 30 kV of anode voltage, between 10 and 40 mA of electrode current, and between 0.29 and 1.1 milliTorr of deuterium gas pressure. A calibration factor for the pressure accounts for the calibration of the ionization pressure gauge in the experiment, and an estimated pressure drop between the main chamber of the C-Device and the pressure gauge that is downstream of the exhaust port. Upgraded versions of the CHIMP code which have modifications to the algorithms for the boundary conditions, and which include charge exchange processes, and the contribution of fast neutrals to the neutron generation rate are also tested against several experimental data points. Although the CHIMP code gives predictions for the neutron generation rate that exhibit the same near-linear trends with current found in the experiment, it is apparent that at least five types of

  11. Feasibility of four-dimensional preoperative simulation for elbow debridement arthroplasty.

    Science.gov (United States)

    Yamamoto, Michiro; Murakami, Yukimi; Iwatsuki, Katsuyuki; Kurimoto, Shigeru; Hirata, Hitoshi

    2016-04-02

    Recent advances in imaging modalities have enabled three-dimensional preoperative simulation. A four-dimensional preoperative simulation system would be useful for debridement arthroplasty of primary degenerative elbow osteoarthritis because it would be able to detect the impingement lesions. We developed a four-dimensional simulation system by adding the anatomical axis to the three-dimensional computed tomography scan data of the affected arm in one position. Eleven patients with primary degenerative elbow osteoarthritis were included. A "two rings" method was used to calculate the flexion-extension axis of the elbow by converting the surface of the trochlea and capitellum into two rings. A four-dimensional simulation movie was created and showed the optimal range of motion and the impingement area requiring excision. To evaluate the reliability of the flexion-extension axis, interobserver and intraobserver reliabilities regarding the assessment of bony overlap volumes were calculated twice for each patient by two authors. Patients were treated by open or arthroscopic debridement arthroplasties. Pre- and postoperative examinations included elbow range of motion measurement, and completion of the patient-rated questionnaire Hand20, Japanese Orthopaedic Association-Japan Elbow Society Elbow Function Score, and the Mayo Elbow Performance Score. Measurement of the bony overlap volume showed an intraobserver intraclass correlation coefficient of 0.93 and 0.90, and an interobserver intraclass correlation coefficient of 0.94. The mean elbow flexion-extension arc significantly improved from 101° to 125°. The mean Hand20 score significantly improved from 52 to 22. The mean Japanese Orthopaedic Association-Japan Elbow Society Elbow Function Score significantly improved from 67 to 88. The mean Mayo Elbow Performance Score significantly improved from 71 to 91 at the final follow-up evaluation. We showed that four-dimensional, preoperative simulation can be generated by

  12. Axial and Radial Gas Holdup in Bubble Column Reactor

    International Nuclear Information System (INIS)

    Wagh, Sameer M.; Ansari, Mohashin E Alan; Kene, Pragati T.

    2014-01-01

    Bubble column reactors are considered the reactor of choice for numerous applications including oxidation, hydrogenation, waste water treatment, and Fischer-Tropsch (FT) synthesis. They are widely used in a variety of industrial applications for carrying out gas-liquid and gas-liquid-solid reactions. In this paper, the computational fluid dynamics (CFD) model is used for predicting the gas holdup and its distribution along radial and axial direction are presented. Gas holdup increases linearly with increase in gas velocity. Gas bubbles tends to concentrate more towards the center of the column and follows a wavy path

  13. Pre-operative assessment of patients undergoing endoscopic, transnasal, transsphenoidal pituitary surgery.

    Science.gov (United States)

    Lubbe, D; Semple, P

    2008-06-01

    To demonstrate the importance of pre-operative ear, nose and throat assessment in patients undergoing endoscopic, transsphenoidal surgery for pituitary tumours. Literature pertaining to the pre-operative otorhinolaryngological assessment and management of patients undergoing endoscopic anterior skull base surgery is sparse. We describe two cases from our series of 59 patients undergoing endoscopic pituitary surgery. The first case involved a young male patient with a large pituitary macroadenoma. His main complaint was visual impairment. He had no previous history of sinonasal pathology and did not complain of any nasal symptoms during the pre-operative neurosurgical assessment. At the time of surgery, a purulent nasal discharge was seen emanating from both middle meati. Surgery was abandoned due to the risk of post-operative meningitis, and postponed until the patient's chronic rhinosinusitis was optimally managed. The second patient was a 47-year-old woman with a large pituitary macroadenoma, who presented to the neurosurgical department with a main complaint of diplopia. She too gave no history of previous nasal problems, and she underwent uneventful surgery using the endoscopic, transnasal approach. Two weeks after surgery, she presented to the emergency unit with severe epistaxis. A previous diagnosis of hereditary haemorrhagic telangiectasia was discovered, and further surgical and medical intervention was required before the epistaxis was finally controlled. Pre-operative otorhinolaryngological assessment is essential prior to endoscopic pituitary or anterior skull base surgery. A thorough otorhinolaryngological history will determine whether any co-morbid diseases exist which could affect the surgical field. Nasal anatomy can be assessed via nasal endoscopy and sinusitis excluded. Computed tomography imaging is a valuable aid to decisions regarding additional procedures needed to optimise access to the pituitary fossa.

  14. Impaired anastomotic healing after preoperative radiotherapy ...

    African Journals Online (AJOL)

    Background. Patients with rectal carcinoma undergoing total mesorectal excision (TME) have a lower recurrence rate with preoperative radiotherapy (RT). The aim of this study was to assess the side-effects in patients who had preoperative RT compared with those who did not receive it (because of palliative resections, ...

  15. Relaxation of axially confined 400 GeV/c protons to planar channeling in a bent crystal

    International Nuclear Information System (INIS)

    Bandiera, L.; Mazzolari, A.; Bagli, E.; Germogli, G.; Guidi, V.; Sytov, A.; Kirillin, I.V.; Shul'ga, N.F.; Berra, A.; Lietti, D.; Prest, M.; De Salvador, D.; Vallazza, E.

    2016-01-01

    An investigation on the mechanism of relaxation of axially confined 400 GeV/c protons to planar channeling in a bent crystal was carried out at the extracted line H8 from CERN Super Proton Synchrotron. The experimental results were critically compared to computer simulations, showing a good agreement. We identified a necessary condition for the exploitation of axial confinement or its relaxation for particle beam manipulation in high-energy accelerators. We introduce the idea of using a short bent crystal, aligned with one of its main axis to the beam direction, as a beam steerer or a beam splitter with adjustable intensity in the field of particle accelerators. In particular, in the latter case, a complete relaxation from axial confinement to planar channeling takes place, resulting in beam splitting into the two strongest skew planar channels. (orig.)

  16. Relaxation of axially confined 400 GeV/c protons to planar channeling in a bent crystal

    Energy Technology Data Exchange (ETDEWEB)

    Bandiera, L.; Mazzolari, A.; Bagli, E.; Germogli, G.; Guidi, V. [Universita di Ferrara, Dipartimento di Fisica, Ferrara (Italy); INFN, Ferrara (Italy); Sytov, A. [Universita di Ferrara, Dipartimento di Fisica, Ferrara (Italy); Belarusian State University, Research Institute for Nuclear Problems, Minsk (Belarus); INFN, Ferrara (Italy); Kirillin, I.V. [National Science Center ' ' Kharkov Institute of Physics and Technology' ' , Akhiezer Institute for Theoretical Physics, Kharkov (Ukraine); Shul' ga, N.F. [National Science Center ' ' Kharkov Institute of Physics and Technology' ' , Akhiezer Institute for Theoretical Physics, Kharkov (Ukraine); V.N. Karazin Kharkov National University, Kharkov (Ukraine); Berra, A.; Lietti, D.; Prest, M. [Universita dell' Insubria, Como (Italy); INFN Sezione di Milano Bicocca, Milan (Italy); De Salvador, D. [INFN Laboratori Nazionali di Legnaro, Legnaro (Italy); Universita di Padova, Dipartimento di Fisica, Padua (Italy); Vallazza, E. [INFN Sezione di Trieste, Trieste (Italy)

    2016-02-15

    An investigation on the mechanism of relaxation of axially confined 400 GeV/c protons to planar channeling in a bent crystal was carried out at the extracted line H8 from CERN Super Proton Synchrotron. The experimental results were critically compared to computer simulations, showing a good agreement. We identified a necessary condition for the exploitation of axial confinement or its relaxation for particle beam manipulation in high-energy accelerators. We introduce the idea of using a short bent crystal, aligned with one of its main axis to the beam direction, as a beam steerer or a beam splitter with adjustable intensity in the field of particle accelerators. In particular, in the latter case, a complete relaxation from axial confinement to planar channeling takes place, resulting in beam splitting into the two strongest skew planar channels. (orig.)

  17. The role of anxiolytic premedication in reducing preoperative anxiety.

    LENUS (Irish Health Repository)

    Carroll, Jennifer K

    2012-01-01

    Prevention of preoperative anxiety with anxiolytic premedication is associated with improved preoperative outcomes in surgical patients. The objective of the authors\\' study was to evaluate the percentage of surgical patients that are prescribed premedication for preoperative anxiety before their anticipated surgical procedure. A prospective study was carried out by theatre nursing staff in the theatre reception bay of a university teaching hospital. A questionnaire was designed to record the number of patients that described symptoms consistent with preoperative anxiety. The number of patients that had been offered anxiolytic premedication for preoperative anxiety was also recorded. Consent was obtained from 115 consecutive surgical patients (male, n=52; female, n=63). Of these, 66% (n=76) reported anxiety before their surgical procedure (male: n=27, female: n=49). Premedication with a low-dose benzodiazepine was prescribed by an anaesthetist in 4% of cases (n=5). Patients that received premedication preoperatively reported effective relief of their anxiety symptoms This study demonstrates that preoperative patient anxiety is highly prevalent. The authors\\' findings suggest that premedication with anxiolytic pharmacological therapy may be an underused therapeutic resource for managing preoperative patient anxiety.

  18. A numerical investigation on the unstable flow in a single stage of an axial compressors

    CERN Document Server

    Farhanieh, B; Ghorbanian, K

    2003-01-01

    An unsteady two-dimensional finite-volume solver was developed based on Van Leer's flux splitting algorithm in conjunction with sup M onotonic Upstream Scheme for Conservation Laws sup l imiters to improve the order of accuracy and the two-layer Baldwin-Lomax turbulence model was also implemented. Two test cases were prepared to validate the solver. The computed results were compared with the experimental data and a good agreement validated the solver. Finally, the solver was used for the flow through a multi-blade stage of an axial compressor in its off-design condition. The computed results showed a rotating stall-like instability with a periodic behavior. To investigate the flow properties during the instability condition, the flow pattern, vortex properties and the axial velocity were studied. It was concluded that the instability vortices in the multi-blade cascade do not have the same generation history of the separated vortices over a single body.

  19. Integration of functional and morphological MR data for preoperative 3D visualisation of tumours. Cervical carcinoma

    International Nuclear Information System (INIS)

    Evers, H.; Meinzer, H.P.; Hawighorst, H.; Kaick, G. van; Knapstein, P.G.

    1998-01-01

    Purpose: The goal of this exemplary study was to integrate morphological and functional MRI to establish computer-based, preoperative therapy planning for tumors, instancing cervical carcinoma. Results: Segmentation of organs and vessels as well as tissue differentiation yielded a morphological visualisation of anatomical structures that were overlaid with pharmacokinetic parameters derived from dynamic MRI, subsequently. Thereby, three-dimensional, arbitrary views on the functional data were displayed. Conclusions: Image analysis and visualisation of the acquired MR data establishes both a morphologic and functional evaluation of suspect lesions and adjacent organs. By integrating morphologic and functional MRI additional information can be gathered that possibly impinge on preoperative planning. (orig./AJ) [de

  20. MRI, CT, and sonography in the preoperative evaluation of primary tumor extension in malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Layer, G.; Steudel, A.; Schild, H.H.; Schmitteckert, H.; Tuengerthal, S.; Schirren, J.; Kaick, G. van

    1999-01-01

    Purpose: Evaluation of the diagnostic value of the imaging modalities computed tomography (CT), magnetic resonance imaging (MRI), and thoracic sonography in the preoperative staging of malignant pleural mesothelioma. Results: The accuracy rates for CT were 85%, 98%, 83%, 73%, 71%, and 83%. MRI had an accuracy of 71%, 92%, 71%, 83%, 71%, and 96%, the thoracic ultrasound examinations of 76%, 63%, 51%, 60%, 71% and 89%. Conclusions: According to these results CT remains the method of choice in the preoperative assessment of T-stage of malignant pleural mesothelioma. MRI is of nearly the same value, but is not a must. Sonography may be supplementary method for operation planning. (orig./AJ) [de

  1. Preoperative assessment of pleural adhesion by Four-Dimensional Ultra-Low-Dose Computed Tomography (4D-ULDCT) with Adaptive Iterative Dose Reduction using Three-Dimensional processing (AIDR-3D).

    Science.gov (United States)

    Hashimoto, Masayuki; Nagatani, Yukihiro; Oshio, Yasuhiko; Nitta, Norihisa; Yamashiro, Tsuneo; Tsukagoshi, Shinsuke; Ushio, Noritoshi; Mayumi, Masayuki; Kimoto, Tatsuya; Igarashi, Tomoyuki; Yoshigoe, Makoto; Iwai, Kyohei; Tanaka, Koki; Sato, Shigetaka; Sonoda, Akinaga; Otani, Hideji; Murata, Kiyoshi; Hanaoka, Jun

    2018-01-01

    To assess the feasibility of Four-Dimensional Ultra-Low-Dose Computed Tomography (4D-ULDCT) for distinguishing pleural aspects with localized pleural adhesion (LPA) from those without. Twenty-seven patients underwent 4D-ULDCT during a single respiration with a 16cm-coverage of the body axis. The presence and severity of LPA was confirmed by their intraoperative thoracoscopic findings. A point on the pleura and a corresponding point on the outer edge of the costal bone were placed in identical axial planes at end-inspiration. The distance of the two points (PCD), traced by automatic tracking functions respectively, was calculated at each respiratory phase. The maximal and average change amounts in PCD (PCD MCA and PCD ACA ) were compared among 110 measurement points (MPs) without LPA, 16MPs with mild LPA and 10MPs with severe LPA in upper lung field cranial to the bronchial bifurcation (ULF), and 150MPs without LPA, 17MPs with mild LPA and 9MPs with severe LPA in lower lung field caudal to the bronchial bifurcation (LLF) using the Mann-Whitney U test. In the LLF, PCD ACA as well as PCD MCA demonstrated a significant difference among non-LPA, mild LPA and severe LPA (18.1±9.2, 12.3±6.2 and 5.0±3.3mm) (p<0.05). Also in the ULF, PCD ACA showed a significant difference among three conditions (9.2±5.5, 5.7±2.8 and 2.2±0.4mm, respectively) (p<0.05), whereas PCD MCA for mild LPA was similar to that for non-LPA (12.3±5.9 and 17.5±11.0mm). Four D-ULDCT could be a useful non-invasive preoperative assessment modality for the detection of the presence or severity of LPA. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. The Distal Humerus Axial View: Assessment of Displacement in Medial Epicondyle Fractures.

    Science.gov (United States)

    Souder, Christopher D; Farnsworth, Christine L; McNeil, Natalie P; Bomar, James D; Edmonds, Eric W

    2015-01-01

    The assessment and treatment of childhood medial epicondyle humerus fractures continues to be associated with significant debate. Several studies demonstrate that standard radiographic views are unable to accurately portray the true displacement. Without reliable ways to assess the amount of displacement, how can we debate treatment and outcomes? This study introduces a novel imaging technique for the evaluation of medial epicondyle fractures. An osteotomy of a cadaveric humerus was performed to simulate a medial epicondyle fracture. Plain radiographs were obtained with the fracture fragment displaced anteriorly in 2-mm increments between 0 and 18 mm. Anteroposterior (AP), internal oblique (IR), lateral (LAT), and distal humerus axial (AXIAL) views were performed. Axial images were obtained by positioning the central ray above the shoulder at 15 to 20 degrees from the long axis of the humerus, centered on the distal humerus. Displacement (mm) was measured by 7 orthopaedic surgeons on digital radiographs. At 10 mm displacement, AP views underestimated displacement by 5.5±0.6 mm and IR views underestimated by 3.8±2.1 mm. On LAT views, readers were not able to visualize fragments with displacement. Displacement ≥10 mm from LAT views was overestimated by 1 reader by up to 4.6 mm and underestimated by others by up to 18.0 mm. AXIAL images more closely estimated the true amount of displacement, with a mean 1.5±1.1 mm error in measurement for displacement and a mean 0.8±0.7 mm error for displacements of ≥10 mm. AXIAL measurements correlated strongly with the actual displacement (r=0.998, Pdisplacement of medial epicondyle humerus fractures. The newly described AXIAL projection more accurately and reliably demonstrated the true displacement while reducing the need for advanced imaging such as computed tomography. This simple view can be easily obtained at a clinic visit, enhancing the surgeon's ability to determine the true displacement.

  3. Design optimization of axial flow hydraulic turbine runner: Part I - an improved Q3D inverse method

    Science.gov (United States)

    Peng, Guoyi; Cao, Shuliang; Ishizuka, Masaru; Hayama, Shinji

    2002-06-01

    With the aim of constructing a comprehensive design optimization procedure of axial flow hydraulic turbine, an improved quasi-three-dimensional inverse method has been proposed from the viewpoint of system and a set of rotational flow governing equations as well as a blade geometry design equation has been derived. The computation domain is firstly taken from the inlet of guide vane to the far outlet of runner blade in the inverse method and flows in different regions are solved simultaneously. So the influence of wicket gate parameters on the runner blade design can be considered and the difficulty to define the flow condition at the runner blade inlet is surmounted. As a pre-computation of initial blade design on S2m surface is newly adopted, the iteration of S1 and S2m surfaces has been reduced greatly and the convergence of inverse computation has been improved. The present model has been applied to the inverse computation of a Kaplan turbine runner. Experimental results and the direct flow analysis have proved the validation of inverse computation. Numerical investigations show that a proper enlargement of guide vane distribution diameter is advantageous to improve the performance of axial hydraulic turbine runner. Copyright

  4. Is pre-operative imaging essential prior to ureteric stone surgery?

    Science.gov (United States)

    Youssef, F R; Wilkinson, B A; Hastie, K J; Hall, J

    2012-09-01

    The aim of this study was to identify patients not requiring ureteric stone surgery based on pre-operative imaging (within 24 hours) prior to embarking on semirigid ureteroscopy (R-URS) for urolithiasis. The imaging of all consecutive patients on whom R-URS for urolithiasis was performed over a 12-month period was reviewed. All patients had undergone a plain x-ray of the kidney, ureters and bladder (KUB), abdominal non-contrast computed tomography (NCCT-KUB) or both on the day of surgery. A total of 96 patients were identified for the study. Stone sizes ranged from 3 mm to 20 mm. Thirteen patients (14%) were cancelled as no stone(s) were identified on pre-operative imaging. Of the patients cancelled, 8 (62%) required NCCT-KUB to confirm spontaneous stone passage. One in seven patients were stone free on the day of surgery. This negates the need for unnecessary anaesthetic and instrumentation of the urinary tract, with the associated morbidity. Up-to-date imaging prior to embarking on elective ureteric stone surgery is highly recommended.

  5. Effective preoperative irradiation of highly vascular cerebellopontine angle neurinomas

    International Nuclear Information System (INIS)

    Ikeda, K.; Ito, H.; Kashihara, K.; Fujisawa, H.; Yamamoto, S.

    1988-01-01

    Three cases of large cerebellopontine angle neurinoma with marked vascularity and tumor staining on the angiogram were treated with effective preoperative irradiation. The radiotherapy was given before the second operation in two cases and before the first operation in the other case. Irradiation doses administered with a linear accelerator were 2.34 to 3.0 Gy for 3 to 3.5 weeks, and radical operations were done 1.5 to 2 months after irradiation. After the irradiation, vertebral angiography showed moderate to marked decrease of the hypervascular capsular stain and disappearance of the early draining vein. Computed tomographic scan showed enlargement of the central necrotic area within the heterogeneously enhanced tumor, which was unchanged in size. Radical operations, which had been impossible because of uncontrollable massive bleeding, were successful without any intraoperative bleeding after radiotherapy. Postirradiation radiological findings corresponded well with those of histopathological examination, which showed decrease in cellularity and in vascularity and diffuse coagulation necrosis around the collapsed tumoral vessels as radiation effects. Preoperative irradiation of the hypervascular neurinoma was though to facilitate radical surgery by abolishing or diminishing the risk of intraoperative bleeding

  6. Axial vector mass spectrum and mixing angles

    International Nuclear Information System (INIS)

    Caffarelli, R.V.; Kang, K.

    1976-01-01

    Spectral sum rules of the axial-vector current and axial-vector current-pseudoscalar field are used to study the axial-vector mass spectrum and mixing angles, as well as the decay constants and mixing angles of the pseudoscalar mesons. In general, the result is quite persuasive for the existence of the Jsup(PC) = 1 ++ multiplet in which one has a canonical D-E mixing. (Auth.)

  7. Rationale for and approach to preoperative opioid weaning: a preoperative optimization protocol

    Directory of Open Access Journals (Sweden)

    Heath McAnally

    2017-11-01

    Full Text Available Abstract The practice of chronic opioid prescription for chronic non-cancer pain has come under considerable scrutiny within the past several years as mounting evidence reveals a generally unfavorable risk to benefit ratio and the nation reels from the grim mortality statistics associated with the opioid epidemic. Patients struggling with chronic pain tend to use opioids and also seek out operative intervention for their complaints, which combination may be leading to increased postoperative “acute-on-chronic” pain and fueling worsened chronic pain and opioid dependence. Besides worsened postoperative pain, a growing body of literature, reviewed herein, indicates that preoperative opioid use is associated with significantly worsened surgical outcomes, and severely increased financial drain on an already severely overburdened healthcare budget. Conversely, there is evidence that preoperative opioid reduction may result in substantial improvements in outcome. In the era of accountable care, efforts such as the Enhanced Recovery After Surgery (ERAS protocol have been introduced in an attempt to standardize and facilitate evidence-based perioperative interventions to optimize surgical outcomes. We propose that addressing preoperative opioid reduction as part of a targeted optimization approach for chronic pain patients seeking surgery is not only logical but mandatory given the stakes involved. Simple opioid reduction/abstinence however is not likely to occur in the absence of provision of viable and palatable alternatives to managing pain, which will require a strong focus upon reducing pain catastrophization and bolstering self-efficacy and resilience. In response to a call from our surgical community toward that end, we have developed a simple and easy-to-implement outpatient preoperative optimization program focusing on gentle opioid weaning/elimination as well as a few other high-yield areas of intervention, requiring a minimum of resources.

  8. Axial flow heat exchanger devices and methods for heat transfer using axial flow devices

    Science.gov (United States)

    Koplow, Jeffrey P.

    2016-02-16

    Systems and methods described herein are directed to rotary heat exchangers configured to transfer heat to a heat transfer medium flowing in substantially axial direction within the heat exchangers. Exemplary heat exchangers include a heat conducting structure which is configured to be in thermal contact with a thermal load or a thermal sink, and a heat transfer structure rotatably coupled to the heat conducting structure to form a gap region between the heat conducting structure and the heat transfer structure, the heat transfer structure being configured to rotate during operation of the device. In example devices heat may be transferred across the gap region from a heated axial flow of the heat transfer medium to a cool stationary heat conducting structure, or from a heated stationary conducting structure to a cool axial flow of the heat transfer medium.

  9. Inverse axial mounting stiffness design for lithographic projection lenses.

    Science.gov (United States)

    Wen-quan, Yuan; Hong-bo, Shang; Wei, Zhang

    2014-09-01

    In order to balance axial mounting stiffness of lithographic projection lenses and the image quality under dynamic working conditions, an easy inverse axial mounting stiffness design method is developed in this article. Imaging quality deterioration at the wafer under different axial vibration levels is analyzed. The desired image quality can be determined according to practical requirements, and axial vibrational tolerance of each lens is solved with the damped least-squares method. Based on adaptive interval adjustment, a binary search algorithm, and the finite element method, the axial mounting stiffness of each lens can be traveled in a large interval, and converges to a moderate numerical solution which makes the axial vibrational amplitude of the lens converge to its axial vibrational tolerance. Model simulation is carried out to validate the effectiveness of the method.

  10. Dai Omega, a large solid angle axial focusing superconducting surface muon channel

    International Nuclear Information System (INIS)

    Miyadera, H.; Nagamine, K.; Shimomura, K.; Nishiyama, K.; Tanaka, H.; Fukuchi, K.; Makimura, S.; Ishida, K.

    2003-01-01

    An axial focusing surface muon channel, Dai Omega, was installed at KEK-MSL in the summer of 2001. Large aperture superconducting coils are utilized instead of quadrupole magnets. Dai Omega adopts an axial focusing beam path using symmetric magnetic fields from four coils. Computer simulations were performed on constructing Dai Omega, and the calculated solid angle acceptance of Dai Omega was larger than 1 sr at the optimum momentum. The momentum acceptance of Dai Omega was 6% FWHM. Dai Omega improved the solid angle acceptance by almost 20 times, in comparison with conventional muon channels. Beam tuning tests of Dai Omega have been carried out, and a beam intensity of 10 6 μ + /s was achieved at KEK-NML (500 MeV, 5 μA), which was almost comparable with that of RAL (800 MeV, 200 μA)

  11. ANSYS UIDL-Based CAE Development of Axial Support System for Optical Mirror

    Science.gov (United States)

    Yang, De-Hua; Shao, Liang

    2008-09-01

    The Whiffle-tree type axial support mechanism is widely adopted by most relatively large optical mirrors. Based on the secondary developing tools offered by the commonly used Finite Element Anylysis (FEA) software ANSYS, ANSYS Parametric Design Language (APDL) is used for creating the mirror FEA model driven by parameters, and ANSYS User Interface Design Language (UIDL) for generating custom menu of interactive manner, whereby, the relatively independent dedicated Computer Aided Engineering (CAE) module is embedded in ANSYS for calculation and optimization of axial Whiffle-tree support of optical mirrors. An example is also described to illustrate the intuitive and effective usage of the dedicated module by boosting work efficiency and releasing related engineering knowledge of user. The philosophy of secondary-developed special module with commonly used software also suggests itself for product development in other industries.

  12. Isotensor Axial Polarizability and Lattice QCD Input for Nuclear Double- β Decay Phenomenology

    Energy Technology Data Exchange (ETDEWEB)

    Shanahan, Phiala E.; Tiburzi, Brian C.; Wagman, Michael L.; Winter, Frank; Chang, Emmanuel; Davoudi, Zohreh; Detmold, William; Orginos, Kostas; Savage, Martin J.

    2017-08-01

    The potential importance of short-distance nuclear effects in double-$\\beta$ decay is assessed using a lattice QCD calculation of the $nn\\rightarrow pp$ transition and effective field theory methods. At the unphysical quark masses used in the numerical computation, these effects, encoded in the isotensor axial polarisability, are found to be of similar magnitude to the nuclear modification of the single axial current, which phenomenologically is the quenching of the axial charge used in nuclear many-body calculations. This finding suggests that nuclear models for neutrinoful and neutrinoless double-$\\beta$ decays should incorporate this previously neglected contribution if they are to provide reliable guidance for next-generation neutrinoless double-$\\beta$ decay searches. The prospects of constraining the isotensor axial polarisabilities of nuclei using lattice QCD input into nuclear many-body calculations are discussed.

  13. Three-dimensional digitizer (neuronavigator): new equipment for computed tomography-guided stereotaxic surgery.

    Science.gov (United States)

    Watanabe, E; Watanabe, T; Manaka, S; Mayanagi, Y; Takakura, K

    1987-06-01

    A new device was invented as an adjunct for computed tomography (CT)-guided stereotaxic or open neurosurgery. It is composed of a multijoint three-dimensional digitizer (sensor arm) and a microcomputer, which indicates the place of the sensor arm tip on preoperative CT images. Computed tomography scan is performed preoperatively with three markers placed on the nasion and ears. At surgery, after fixing the patient's head and the sensor arm, sampling of the standard points was done to translate the position of the tip of the sensor arm onto the CT images displayed on a computer screen. In this way positional data from conventional preoperative CT scan can be directly transferred into the surgical field. This system has the unique feature of introducing CT-guided stereotaxis into conventional open neurosurgery.

  14. X-ray detectors in axial computed tomography development; Sensori di radiazioni X negli sviluppi della tomografia assiale computerizzata

    Energy Technology Data Exchange (ETDEWEB)

    Gislon, R.; Imperiali, F. [ENEA, Centro Ricerche Casaccia, Rome (Italy). Dip. Innovazione

    1996-12-01

    The increase of potentially of axial computed tomography as a non destructive investigation method in industrial field is particularly tied to the development of the X-rays detectors. The transition from the first gas ionization detectors to the last semiconductor detectors has indeed dramatically increased the performances of tomographic systems. In this report, after a quick analysis of fundamental principles of tomography, the most significant parameters for a detector to be used in a tomographic system are reviewed. The examination of the principal kinds of detectors that have been up to now used, with their working schemes, allows to delineate their characteristics and so to compare them with the ideal detector sketched above. The necessity of using high definition arrays brings to put into evidence the inadequacy of both gas and liquid ionization detectors and also of those types of light conversion devices which utilize for signal amplification a photomultiplier tube. Systems based on charge coupled devices or on a light conversion obtained with semiconductor photodiode arrays are definitely to be preferred. The progress of the last years in microelectronic technologies has brought great improvements in this field.

  15. Can Axial-Based Nodal Size Criteria Be Used in Other Imaging Planes to Accurately Determine “Enlarged” Head and Neck Lymph Nodes?

    Science.gov (United States)

    Bartlett, Eric S.; Walters, Thomas D.; Yu, Eugene

    2013-01-01

    Objective. We evaluate if axial-based lymph node size criteria can be applied to coronal and sagittal planes. Methods. Fifty pretreatment computed tomographic (CT) neck exams were evaluated in patients with head and neck squamous cell carcinoma (SCCa) and neck lymphadenopathy. Axial-based size criteria were applied to all 3 imaging planes, measured, and classified as “enlarged” if equal to or exceeding size criteria. Results. 222 lymph nodes were “enlarged” in one imaging plane; however, 53.2% (118/222) of these were “enlarged” in all 3 planes. Classification concordance between axial versus coronal/sagittal planes was poor (kappa = −0.09 and −0.07, resp., P planes. Conclusion. Classification of “enlarged” lymph nodes differs between axial versus coronal/sagittal imaging planes when axial-based nodal size criteria are applied independently to all three imaging planes, and exclusively used without other morphologic nodal data. PMID:23984099

  16. Cement stress predictions after anatomic total shoulder arthroplasty are correlated with preoperative glenoid bone quality.

    Science.gov (United States)

    Terrier, Alexandre; Obrist, Raphaël; Becce, Fabio; Farron, Alain

    2017-09-01

    We hypothesized that biomechanical parameters typically associated with glenoid implant failure after anatomic total shoulder arthroplasty (aTSA) would be correlated with preoperative glenoid bone quality. We developed an objective automated method to quantify preoperative glenoid bone quality in different volumes of interest (VOIs): cortical bone, subchondral cortical plate, subchondral bone after reaming, subchondral trabecular bone, and successive layers of trabecular bone. Average computed tomography (CT) numbers (in Hounsfield units [HU]) were measured in each VOI from preoperative CT scans. In parallel, we built patient-specific finite element models of simulated aTSAs to predict cement stress, bone-cement interfacial stress, and bone strain around the glenoid implant. CT measurements and finite element predictions were obtained for 20 patients undergoing aTSA for primary glenohumeral osteoarthritis. We tested all linear correlations between preoperative patient characteristics (age, sex, height, weight, glenoid bone quality) and biomechanical predictions (cement stress, bone-cement interfacial stress, bone strain). Average CT numbers gradually decreased from cortical (717 HU) to subchondral and trabecular (362 HU) bone. Peak cement stress (4-10 MPa) was located within the keel hole, above the keel, or behind the glenoid implant backside. Cement stress, bone-cement interfacial stress, and bone strain were strongly negatively correlated with preoperative glenoid bone quality, particularly in VOIs behind the implant backside (subchondral trabecular bone) but also in deeper trabecular VOIs. Our numerical study suggests that preoperative glenoid bone quality is an important parameter to consider in aTSA, which may be associated with aseptic loosening of the glenoid implant. These initial results should now be confronted with clinical and radiologic outcomes. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc

  17. Prosthesis alignment affects axial rotation motion after total knee replacement: a prospective in vivo study combining computed tomography and fluoroscopic evaluations

    Directory of Open Access Journals (Sweden)

    Harman Melinda K

    2012-10-01

    Full Text Available Abstract Background Clinical consequences of alignment errors in total knee replacement (TKR have led to the rigorous evaluation of surgical alignment techniques. Rotational alignment in the transverse plane has proven particularly problematic, with errors due to component malalignment relative to bone anatomic landmarks and an overall mismatch between the femoral and tibial components’ relative positions. Ranges of nominal rotational alignment are not well defined, especially for the tibial component and for relative rotational mismatch, and some studies advocate the use of mobile-bearing TKR to accommodate the resulting small rotation errors. However, the relationships between prosthesis rotational alignment and mobile-bearing polyethylene insert motion are poorly understood. This prospective, in vivo study evaluates whether component malalignment and mismatch affect axial rotation motions during passive knee flexion after TKR. Methods Eighty patients were implanted with mobile-bearing TKR. Rotational alignment of the femoral and tibial components was measured from postoperative CT scans. All TKR were categorized into nominal or outlier groups based on defined norms for surgical rotational alignment relative to bone anatomic landmarks and relative rotational mismatch between the femoral and tibial components. Axial rotation motion of the femoral, tibial and polyethylene bearing components was measured from fluoroscopic images acquired during passive knee flexion. Results Axial rotation motion was generally accomplished in two phases, dominated by polyethylene bearing rotation on the tibial component in early to mid-flexion and then femoral component rotation on the polyethylene articular surface in later flexion. Opposite rotations of the femur-bearing and bearing-baseplate articulations were evident at flexion greater than 80°. Knees with outlier alignment had lower magnitudes of axial rotation and distinct transitions from external to

  18. Estimation of axial diffusion processes by analog Monte-Carlo: theory, tests and examples

    International Nuclear Information System (INIS)

    Milgram, M.S.

    1997-01-01

    With the advent of fast, reasonably inexpensive computer hardware, it has become possible to follow the histories of several million particles and tally quantities such as currents and fluxes in a finite reactor region using analog Monte-Carlo. Here use is made of this new capability to demonstrate that it is possible to test various approximations that cumulatively are known as the axial diffusion approximation in a realistic, heterogenous reactor lattice cell. From this, it proves possible to extract excellent estimates of the homogenized diffusion coefficient in few energy groups and lattice sub-regions for further comparison with deterministic methods of deriving the same quantity. The breakdown of the diffusion approximation near the endpoints of the axial lattice cell, as well as in the moderator at certain energies, can be observed. (Author)

  19. Safety screw fixation technique in a case of coracoid base fracture with acromioclavicular dislocation and coracoid base cross-sectional size data from a computed axial tomography study.

    Science.gov (United States)

    Kawasaki, Yoshiteru; Hirano, Tetsuya; Miyatake, Katsutoshi; Fujii, Koji; Takeda, Yoshitsugu

    2014-07-01

    Coracoid base fracture accompanied by acromioclavicular joint dislocation with intact coracoclavicular ligaments is a rare injury. Generally, an open reduction with screw fixation is the first treatment choice, as it protects the important structures around the coracoid process. This report presents a new technique of screw fixation for coracoid base fracture and provides anatomic information on cross-sectional size of the coracoid base obtained by computed tomography (CT). An axial image of the coracoid base was visualized over the neck of the scapula, and a guidewire was inserted into this circle under fluoroscopic guidance. The wire was inserted easily into the neck of scapula across the coracoid base fracture with imaging in only 1 plane. In addition, 25 measurements of the coracoid base were made in 25 subjects on axial CT images. Average length of the long and short axes at the thinnest part of the coracoid base was 13.9 ± 2.0 mm (range 10.6-17.0) and 10.5 ± 2.2 mm (6.6-15.1), respectively. This new screw fixation technique and measurement data on the coracoid base may be beneficial for safety screw fixation of coracoid base fracture.

  20. Lung surgery assisted by multidetector-row computed tomographic simulation

    International Nuclear Information System (INIS)

    Oizumi, Hiroyuki; Endoh, Makoto; Ota, Hiroshi; Takeda, Shinichi; Suzuki, Jun; Fukaya, Ken; Chiba, Masato; Sadahiro, Mitsuaki

    2009-01-01

    We describe the benefits of lung resection simulation using multidetector computed tomography (MDCT). Since 2004, the 1.0-mm slice digital imaging and communications in medicine (DICOM) server has been used for storing data obtained using 64-row MDCT. We observed that an abnormality could not be visualized from the pleural surface in 10 nodules of 18 lesions undergoing wedge lung resection. These 10 nodules were resected through simulation using a three-dimensional (3D) volume-rendering method by considering parameters such as the position, depth, or distance from the interlobar abnormalities, etc., without the need for any marking methods. For lung lobectomy, identification of the branching structures, diameter, and length of the arteries is useful in selecting the procedure for blood vessel treatment. However, in the initial 10 patients of this series, the preoperative identification of 2 small arterial branches was unsuccessful when this method was used. Therefore, it is important to carefully examine the original data in all 3 views, id est (i.e.), axial, sagittal, and coronal views. The visualization of venous branches in affected segments and intersegmental veins has facilitated the preoperative determination of the anatomical intersegmental plane. We divided the cases of thoracoscopic lung segmentectomy into 3 groups (level 1: simple, level 2: intermediate, and level 3: complex) on the basis of the technical complexity. Only level 1 segmentectomies were performed without MDCT simulation. Further, level 2 and 3 segmentectomies could be successfully performed because of the introduction of MDCT simulation in 25 of 35 patients. Thus, this simulation technique may be useful during a thoracoscopic procedure for lung surgery. (author)

  1. PET/CT and histopathologic response to preoperative chemoradiation therapy in locally advanced rectal cancer

    DEFF Research Database (Denmark)

    Kristiansen, C.; Loft, A.; Berthelsen, Anne Kiil

    2008-01-01

    PURPOSE: The objective of this study was to investigate the possibility of using positron emission tomography/computer tomography to predict the histopathologic response in locally advanced rectal cancer treated with preoperative chemoradiation. METHODS: The study included 30 patients with locally...... is not able to predict the histopathologic response in locally advanced rectal cancer. There is an obvious need for other complementary methods especially with respect to the low sensitivity of positron emission tomography/computer tomography Udgivelsesdato: 2008/1...... advanced rectal adenocarcinoma treated with a combination of radiotherapy and concurrent Uftoral (uracil, tegafur) and leucovorine. All patients were evaluated by positron emission tomography/computer tomography scan seven weeks after end of chemoradiation, and the results were compared to histopathologic...

  2. PET/CT and Histopathologic Response to Preoperative Chemoradiation Therapy in Locally Advanced Rectal Cancer

    DEFF Research Database (Denmark)

    Kristiansen, Charlotte; Loft, Annika; Berthelsen, Anne K

    2008-01-01

    PURPOSE: The objective of this study was to investigate the possibility of using positron emission tomography/computer tomography to predict the histopathologic response in locally advanced rectal cancer treated with preoperative chemoradiation. METHODS: The study included 30 patients with locally...... of chemoradiation is not able to predict the histopathologic response in locally advanced rectal cancer. There is an obvious need for other complementary methods especially with respect to the low sensitivity of positron emission tomography/computer tomography....... advanced rectal adenocarcinoma treated with a combination of radiotherapy and concurrent Uftoral(R) (uracil, tegafur) and leucovorine. All patients were evaluated by positron emission tomography/computer tomography scan seven weeks after end of chemoradiation, and the results were compared...

  3. Preoperative breast radiation therapy: Indications and perspectives

    DEFF Research Database (Denmark)

    Lightowlers, S V; Boersma, L J; Fourquet, A

    2017-01-01

    Preoperative breast radiation therapy (RT) is not a new concept, but older studies failed to change practice. More recently, there has been interest in revisiting preoperative RT using modern techniques. This current perspective discusses the indications, summarises the published literature and t...

  4. Quality assurance of pre-operative assessment--a review of quality assurance activities related to pre-operative assessment in nine hospitals in The Netherlands

    NARCIS (Netherlands)

    Klazinga, N. S.; Helsloot, R.

    1989-01-01

    Pre-operative assessment of patients for surgery is one of the most prevalent topics for quality assurance by peer-review in Dutch hospitals. This article describes the experiences with pre-operative assessment in nine hospitals. It is discussed why preoperative assessment is performed, what tests

  5. Mutual control of axial and equatorial ligands: model studies with [Ni]-bacteriochlorophyll-a.

    Science.gov (United States)

    Yerushalmi, Roie; Noy, Dror; Baldridge, Kim K; Scherz, Avigdor

    2002-07-17

    ) computationally, we found that a reduction of [Ni]-BChl*imidazole results in a weaker metal-axial ligand bond. Yet, it remains weakly bound in the gas phase. The experimentally observed ligand dissociation is accounted for computationally when solvation is considered. On the basis of the experimental observations and QM calculations, we propose a mechanism whereby alterations in the equatorial pi system and modulation of sigma bonding between the axial ligands and the metal core are mutually correlated. Such a mechanism highlights the dynamic role of axial ligands in regulating the activity of metal centers such as factor F430 (F430), a nickel-based coenzyme that is essential in methanogenic archea.

  6. Dynamic analysis of an axially moving beam subject to inner pressure using finite element method

    Energy Technology Data Exchange (ETDEWEB)

    Hua, Hongliang; Qiu, Ming; Liao, Zhenqiang [Nanjing University of Science and Technology, Nanjing (China)

    2017-06-15

    A dynamic model of an axially moving flexible beam subject to an inner pressure is present. The coupling principle between a flexible beam and inner pressure is analyzed first, and the potential energy of the inner pressure due to the beam bending is derived using the principle of virtual work. A 1D hollow beam element contain inner pressure is established. The finite element method and Lagrange’s equation are used to derive the motion equations of the axially moving system. The dynamic responses are analyzed by Newmark-β time integration method. Based on the computed dynamic responses, the effects of inner pressure on beam dynamics are discussed. Some interesting phenomenon is observed.

  7. Energy Dissipation in Sandwich Structures During Axial Compression

    DEFF Research Database (Denmark)

    Urban, Jesper

    2002-01-01

    The purpose of this paper is to investigate the energy dissipation in sandwich structures during axial crushing. Axial crushing tests on six sandwich elements are described. The sandwich elements consist of a polyurethane core and E-glass/Polyester skin. The elements compare to full-scale structu......The purpose of this paper is to investigate the energy dissipation in sandwich structures during axial crushing. Axial crushing tests on six sandwich elements are described. The sandwich elements consist of a polyurethane core and E-glass/Polyester skin. The elements compare to full...

  8. Improved axial position detection in optical tweezers measurements

    DEFF Research Database (Denmark)

    Dreyer, Jakob Kisbye; Berg-Sørensen, Kirstine; Oddershede, Lene

    2004-01-01

    We investigate the axial position detection of a trapped microsphere in an optical trap by using a quadrant photodiode. By replacing the photodiode with a CCD camera, we obtain detailed information on the light scattered by the microsphere. The correlation of the interference pattern with the axial...... position displays complex behavior with regions of positive and negative interference. By analyzing the scattered light intensity as a function of the axial position of the trapped sphere, we propose a simple method to increase the sensitivity and control the linear range of axial position detection....

  9. Comparison of femoropopliteal artery stents under axial and radial compression, axial tension, bending, and torsion deformations.

    Science.gov (United States)

    Maleckis, Kaspars; Deegan, Paul; Poulson, William; Sievers, Cole; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey

    2017-11-01

    High failure rates of Peripheral Arterial Disease (PAD) stenting appear to be associated with the inability of certain stent designs to accommodate severe biomechanical environment of the femoropopliteal artery (FPA) that bends, twists, and axially compresses during limb flexion. Twelve Nitinol stents (Absolute Pro, Supera, Lifestent, Innova, Zilver, Smart Control, Smart Flex, EverFlex, Viabahn, Tigris, Misago, and Complete SE) were quasi-statically tested under bench-top axial and radial compression, axial tension, bending, and torsional deformations. Stents were compared in terms of force-strain behavior, stiffness, and geometrical shape under each deformation mode. Tigris was the least stiff stent under axial compression (6.6N/m axial stiffness) and bending (0.1N/m) deformations, while Smart Control was the stiffest (575.3N/m and 105.4N/m, respectively). Under radial compression Complete SE was the stiffest (892.8N/m), while Smart Control had the lowest radial stiffness (211.0N/m). Viabahn and Supera had the lowest and highest torsional stiffness (2.2μNm/° and 959.2μNm/°), respectively. None of the 12 PAD stents demonstrated superior characteristics under all deformation modes and many experienced global buckling and diameter pinching. Though it is yet to be determined which of these deformation modes might have greater clinical impact, results of the current analysis may help guide development of new stents with improved mechanical characteristics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Do Mixed-Flora Preoperative Urine Cultures Matter?

    Science.gov (United States)

    Polin, Michael R; Kawasaki, Amie; Amundsen, Cindy L; Weidner, Alison C; Siddiqui, Nazema Y

    2017-06-01

    To determine whether mixed-flora preoperative urine cultures, as compared with no-growth preoperative urine cultures, are associated with a higher prevalence of postoperative urinary tract infections (UTIs). This was a retrospective cohort study. Women who underwent urogynecologic surgery were included if their preoperative clean-catch urine culture result was mixed flora or no growth. Women were excluded if they received postoperative antibiotics for reasons other than treatment of a UTI. Women were divided into two cohorts based on preoperative urine culture results-mixed flora or no growth; the prevalence of postoperative UTI was compared between cohorts. Baseline characteristics were compared using χ 2 or Student t tests. A logistic regression analysis then was performed. We included 282 women who were predominantly postmenopausal, white, and overweight. There were many concomitant procedures; 46% underwent a midurethral sling procedure and 68% underwent pelvic organ prolapse surgery. Preoperative urine cultures resulted as mixed flora in 192 (68%) and no growth in 90 (32%) patients. Overall, 14% were treated for a UTI postoperatively. There was no difference in the proportion of patients treated for a postoperative UTI between the two cohorts (25 mixed flora vs 13 no growth, P = 0.77). These results remained when controlling for potentially confounding variables in a logistic regression model (adjusted odds ratio 0.92, 95% confidence interval 0.43-1.96). In women with mixed-flora compared with no-growth preoperative urine cultures, there were no differences in the prevalence of postoperative UTI. The clinical practice of interpreting mixed-flora cultures as negative is appropriate.

  11. Effect of blade sweep on inlet flow in axial compressor cascades

    Directory of Open Access Journals (Sweden)

    Hao Chang

    2015-02-01

    Full Text Available This paper presents comparative numerical studies to investigate the effects of blade sweep on inlet flow in axial compressor cascades. A series of swept and straight cascades was modeled in order to obtain a general understanding of the inlet flow field that is induced by sweep. A computational fluid dynamics (CFD package was used to simulate the cascades and obtain the required three-dimensional (3D flow parameters. A circumferentially averaged method was introduced which provided the circumferential fluctuation (CF terms in the momentum equation. A program for data reduction was conducted to obtain a circumferentially averaged flow field. The influences of the inlet flow fields of the cascades were studied and spanwise distributions of each term in the momentum equation were analyzed. The results indicate that blade sweep does affect inlet radial equilibrium. The characteristic of radial fluid transfer is changed and thus influencing the axial velocity distributions. The inlet flow field varies mainly due to the combined effect of the radial pressure gradient and the CF component. The axial velocity varies consistently with the incidence variation induced by the sweep, as observed in the previous literature. In addition, factors that might influence the radial equilibrium such as blade camber angles, solidity and the effect of the distance from the leading edge are also taken into consideration and comparatively analyzed.

  12. Application of advanced virtual reality and 3D computer assisted technologies in tele-3D-computer assisted surgery in rhinology.

    Science.gov (United States)

    Klapan, Ivica; Vranjes, Zeljko; Prgomet, Drago; Lukinović, Juraj

    2008-03-01

    The real-time requirement means that the simulation should be able to follow the actions of the user that may be moving in the virtual environment. The computer system should also store in its memory a three-dimensional (3D) model of the virtual environment. In that case a real-time virtual reality system will update the 3D graphic visualization as the user moves, so that up-to-date visualization is always shown on the computer screen. Upon completion of the tele-operation, the surgeon compares the preoperative and postoperative images and models of the operative field, and studies video records of the procedure itself Using intraoperative records, animated images of the real tele-procedure performed can be designed. Virtual surgery offers the possibility of preoperative planning in rhinology. The intraoperative use of computer in real time requires development of appropriate hardware and software to connect medical instrumentarium with the computer and to operate the computer by thus connected instrumentarium and sophisticated multimedia interfaces.

  13. Axial anomalies of Lifshitz fermions

    CERN Document Server

    Bakas, Ioannis

    2011-01-01

    We compute the axial anomaly of a Lifshitz fermion theory with anisotropic scaling z=3 which is minimally coupled to geometry in 3+1 space-time dimensions. We find that the result is identical to the relativistic case using path integral methods. An independent verification is provided by showing with spectral methods that the eta-invariant of the Dirac and Lifshitz fermion operators in three dimensions are equal. Thus, by the integrated form of the anomaly, the index of the Dirac operator still accounts for the possible breakdown of chiral symmetry in non-relativistic theories of gravity. We apply this framework to the recently constructed gravitational instanton backgrounds of Horava-Lifshitz theory and find that the index is non-zero provided that the space-time foliation admits leaves with harmonic spinors. Using Hitchin's construction of harmonic spinors on Berger spheres, we obtain explicit results for the index of the fermion operator on all such gravitational instanton backgrounds with SU(2)xU(1) isom...

  14. Performance Analysis of a Fluidic Axial Oscillation Tool for Friction Reduction with the Absence of a Throttling Plate

    Directory of Open Access Journals (Sweden)

    Xinxin Zhang

    2017-04-01

    Full Text Available An axial oscillation tool is proved to be effective in solving problems associated with high friction and torque in the sliding drilling of a complex well. The fluidic axial oscillation tool, based on an output-fed bistable fluidic oscillator, is a type of axial oscillation tool which has become increasingly popular in recent years. The aim of this paper is to analyze the dynamic flow behavior of a fluidic axial oscillation tool with the absence of a throttling plate in order to evaluate its overall performance. In particular, the differences between the original design with a throttling plate and the current default design are profoundly analyzed, and an improvement is expected to be recorded for the latter. A commercial computational fluid dynamics code, Fluent, was used to predict the pressure drop and oscillation frequency of a fluidic axial oscillation tool. The results of the numerical simulations agree well with corresponding experimental results. A sufficient pressure pulse amplitude with a low pressure drop is desired in this study. Therefore, a relative pulse amplitude of pressure drop and displacement are introduced in our study. A comparison analysis between the two designs with and without a throttling plate indicates that when the supply flow rate is relatively low or higher than a certain value, the fluidic axial oscillation tool with a throttling plate exhibits a better performance; otherwise, the fluidic axial oscillation tool without a throttling plate seems to be a preferred alternative. In most of the operating circumstances in terms of the supply flow rate and pressure drop, the fluidic axial oscillation tool performs better than the original design.

  15. Clinical utility of ultrasound and 99mTc sestamibi SPECT/CT for preoperative localization of parathyroid adenoma in patients with primary hyperparathyroidism

    International Nuclear Information System (INIS)

    Patel, C.N.; Salahudeen, H.M.; Lansdown, M.; Scarsbrook, A.F.

    2010-01-01

    Aim: To evaluate the accuracy of ultrasound and parathyroid scintigraphy using single photon-emission computed tomography/computed tomography (SPECT/CT) for the preoperative localization of solitary parathyroid adenomas in patients with primary hyperparathyroidism who would be suitable for minimally invasive parathyroid surgery. Materials and methods: Retrospective study of 63 consecutive patients with biochemical evidence of primary hyperparathyroidism referred for preoperative localization of parathyroid adenoma that proceeded to surgery in the same institution. All patients underwent high-resolution ultrasound and Technetium-99m sestamibi scintigraphy with planar and SPECT/CT imaging. The accuracy of preoperative imaging was compared to surgical and histological findings as the reference standard. Results: Fifty-nine patients had solitary parathyroid adenomas, three patients had multiglandular hyperplasia, and one patient had multiple parathyroid adenomas confirmed at surgery and histology. Thirty-five solitary parathyroid adenomas were identified preoperatively with ultrasound (64%) and 53 with SPECT-CT (90%). Concordant ultrasound and SPECT/CT findings were found in 35 cases (59%). An additional three adenomas were found with ultrasound alone and 18 adenomas with SPECT/CT alone. Fifty-one of the 56 adenomas localized using combined ultrasound and SPECT/CT were found at the expected sites during surgery. Combined ultrasound and SPECT/CT has an overall sensitivity of 95% and accuracy of 91% for the preoperative localization of solitary parathyroid adenomas. Conclusions: The combination of ultrasound and SPECT/CT has incremental value in accurately localizing solitary parathyroid adenomas over either technique alone, and allows selection of patients with primary hyperparathyroidism who would be suitable for minimally invasive surgery.

  16. Axial anomaly at finite temperature and finite density

    International Nuclear Information System (INIS)

    Qian Zhixin; Su Rukeng; Yu, P.K.N.

    1994-01-01

    The U(1) axial anomaly in a hot fermion medium is investigated by using the real time Green's function method. After calculating the lowest order triangle diagrams, we find that finite temperature as well as finite fermion density does not affect the axial anomaly. The higher order corrections for the axial anomaly are discussed. (orig.)

  17. Study on the Influence of Blade Roughnesson Axial Flow Compressor Stage Performance

    Directory of Open Access Journals (Sweden)

    Shi Xudong

    2017-01-01

    Full Text Available A typically actual inlet stage NASA Stage 36 is chosen to study the influence of surface roughness on axial compressor performance. Firstly, a geometry model is created by blade design software BladeGen using transferred coordinates data of blade profile and flow path. Secondly, validation of simulation model is conducted by comparing computational data and field experiment data. Lastly, SST k-ω turbulence model is chosen to study the influence of blade surface roughness on performance parameters under different work points. It shows that adding roughness will significantly reduce axial compressor stage’s adiabatic efficiency and total pressure ratio and cause stage characteristic map shift toward left. It should not neglect the influence of surface roughness of stator near stall region under 100% design speed; Mach number shows a big difference after adding surface roughness, and it can be considered as a sensibility parameter of roughness.

  18. [Basic concept in computer assisted surgery].

    Science.gov (United States)

    Merloz, Philippe; Wu, Hao

    2006-03-01

    To investigate application of medical digital imaging systems and computer technologies in orthopedics. The main computer-assisted surgery systems comprise the four following subcategories. (1) A collection and recording process for digital data on each patient, including preoperative images (CT scans, MRI, standard X-rays), intraoperative visualization (fluoroscopy, ultrasound), and intraoperative position and orientation of surgical instruments or bone sections (using 3D localises). Data merging based on the matching of preoperative imaging (CT scans, MRI, standard X-rays) and intraoperative visualization (anatomical landmarks, or bone surfaces digitized intraoperatively via 3D localiser; intraoperative ultrasound images processed for delineation of bone contours). (2) In cases where only intraoperative images are used for computer-assisted surgical navigation, the calibration of the intraoperative imaging system replaces the merged data system, which is then no longer necessary. (3) A system that provides aid in decision-making, so that the surgical approach is planned on basis of multimodal information: the interactive positioning of surgical instruments or bone sections transmitted via pre- or intraoperative images, display of elements to guide surgical navigation (direction, axis, orientation, length and diameter of a surgical instrument, impingement, etc. ). And (4) A system that monitors the surgical procedure, thereby ensuring that the optimal strategy defined at the preoperative stage is taken into account. It is possible that computer-assisted orthopedic surgery systems will enable surgeons to better assess the accuracy and reliability of the various operative techniques, an indispensable stage in the optimization of surgery.

  19. Computer assisted surgery for malunited fractures in upper limb

    International Nuclear Information System (INIS)

    Yoneda, Masahiro; Kazuki, Kenichi; Uemura, Takuya; Okada, Mitsuhiro; Takaoka, Kunio

    2006-01-01

    Our objective was to evaluate the usefulness of computer-assisted preoperative simulation of malunited fractures in the upper limb. Ten patients with malunited fractures underwent multislice computed tomography of both upper limbs with reconstruction of three-dimensional bone models using three-dimensional (3D) software. Preoperative simulation was comprised of four main procedures: performance of virtual corrective osteotomy, matching of reposition with a mirror-image model of the unaffected side, creating new data for the bone defect, and machining of an hydroxyapatite block as bone graft. In addition, we used full-sized three-dimensional virtual reality modeling with a rapid prototyping molding device, and performed preoperative rehearsals of osteotomies using plaster models. All patients tolerated the surgical procedure well. This technique permits the surgeon to recognize and correct three-dimensional deformities of malunited fracture with both accuracy and precision. (author)

  20. Review of Axial Burnup Distribution Considerations for Burnup Credit Calculations

    International Nuclear Information System (INIS)

    Wagner, J.C.; DeHart, M.D.

    2000-01-01

    This report attempts to summarize and consolidate the existing knowledge on axial burnup distribution issues that are important to burnup credit criticality safety calculations. Recently released Nuclear Regulatory Commission (NRC) staff guidance permits limited burnup credit, and thus, has prompted resolution of the axial burnup distribution issue. The reactivity difference between the neutron multiplication factor (keff) calculated with explicit representation of the axial burnup distribution and keff calculated assuming a uniform axial burnup is referred to as the ''end effect.'' This end effect is shown to be dependent on many factors, including the axial-burnup profile, total accumulated burnup, cooling time, initial enrichment, assembly design, and the isotopics considered (i.e., actinide-only or actinides plus fission products). Axial modeling studies, efforts related to the development of axial-profile databases, and the determination of bounding axial profiles are also discussed. Finally, areas that could benefit from further efforts are identified

  1. Prognostic significance of tumor size of small lung adenocarcinomas evaluated with mediastinal window settings on computed tomography.

    Directory of Open Access Journals (Sweden)

    Yukinori Sakao

    Full Text Available BACKGROUND: We aimed to clarify that the size of the lung adenocarcinoma evaluated using mediastinal window on computed tomography is an important and useful modality for predicting invasiveness, lymph node metastasis and prognosis in small adenocarcinoma. METHODS: We evaluated 176 patients with small lung adenocarcinomas (diameter, 1-3 cm who underwent standard surgical resection. Tumours were examined using computed tomography with thin section conditions (1.25 mm thick on high-resolution computed tomography with tumour dimensions evaluated under two settings: lung window and mediastinal window. We also determined the patient age, gender, preoperative nodal status, tumour size, tumour disappearance ratio, preoperative serum carcinoembryonic antigen levels and pathological status (lymphatic vessel, vascular vessel or pleural invasion. Recurrence-free survival was used for prognosis. RESULTS: Lung window, mediastinal window, tumour disappearance ratio and preoperative nodal status were significant predictive factors for recurrence-free survival in univariate analyses. Areas under the receiver operator curves for recurrence were 0.76, 0.73 and 0.65 for mediastinal window, tumour disappearance ratio and lung window, respectively. Lung window, mediastinal window, tumour disappearance ratio, preoperative serum carcinoembryonic antigen levels and preoperative nodal status were significant predictive factors for lymph node metastasis in univariate analyses; areas under the receiver operator curves were 0.61, 0.76, 0.72 and 0.66, for lung window, mediastinal window, tumour disappearance ratio and preoperative serum carcinoembryonic antigen levels, respectively. Lung window, mediastinal window, tumour disappearance ratio, preoperative serum carcinoembryonic antigen levels and preoperative nodal status were significant factors for lymphatic vessel, vascular vessel or pleural invasion in univariate analyses; areas under the receiver operator curves were 0

  2. Prognostic Significance of Tumor Size of Small Lung Adenocarcinomas Evaluated with Mediastinal Window Settings on Computed Tomography

    Science.gov (United States)

    Sakao, Yukinori; Kuroda, Hiroaki; Mun, Mingyon; Uehara, Hirofumi; Motoi, Noriko; Ishikawa, Yuichi; Nakagawa, Ken; Okumura, Sakae

    2014-01-01

    Background We aimed to clarify that the size of the lung adenocarcinoma evaluated using mediastinal window on computed tomography is an important and useful modality for predicting invasiveness, lymph node metastasis and prognosis in small adenocarcinoma. Methods We evaluated 176 patients with small lung adenocarcinomas (diameter, 1–3 cm) who underwent standard surgical resection. Tumours were examined using computed tomography with thin section conditions (1.25 mm thick on high-resolution computed tomography) with tumour dimensions evaluated under two settings: lung window and mediastinal window. We also determined the patient age, gender, preoperative nodal status, tumour size, tumour disappearance ratio, preoperative serum carcinoembryonic antigen levels and pathological status (lymphatic vessel, vascular vessel or pleural invasion). Recurrence-free survival was used for prognosis. Results Lung window, mediastinal window, tumour disappearance ratio and preoperative nodal status were significant predictive factors for recurrence-free survival in univariate analyses. Areas under the receiver operator curves for recurrence were 0.76, 0.73 and 0.65 for mediastinal window, tumour disappearance ratio and lung window, respectively. Lung window, mediastinal window, tumour disappearance ratio, preoperative serum carcinoembryonic antigen levels and preoperative nodal status were significant predictive factors for lymph node metastasis in univariate analyses; areas under the receiver operator curves were 0.61, 0.76, 0.72 and 0.66, for lung window, mediastinal window, tumour disappearance ratio and preoperative serum carcinoembryonic antigen levels, respectively. Lung window, mediastinal window, tumour disappearance ratio, preoperative serum carcinoembryonic antigen levels and preoperative nodal status were significant factors for lymphatic vessel, vascular vessel or pleural invasion in univariate analyses; areas under the receiver operator curves were 0.60, 0.81, 0

  3. Exact and analytic solutions of the Ernst equation governing axially symmetric stationary vacuum gravitational fields

    International Nuclear Information System (INIS)

    Baxter, Mathew; Van Gorder, Robert A

    2013-01-01

    We obtain solutions to a transformation of the axially symmetric Ernst equation, which governs a class of exact solutions of Einstein's field equations. Physically, the equation serves as a model of axially symmetric stationary vacuum gravitational fields. By an application of the method of homotopy analysis, we are able to construct approximate analytic solutions to the relevant boundary value problem in the case where exact solutions are not possible. The results presented constitute a solution for a complicated nonlinear and singular initial value problem. Through appropriate selection of the auxiliary linear operator and convergence control parameter, we are able to obtain low order approximations which minimize residual error over the problem domain. The benefit to such approach is that we obtain very accurate approximations after computing very few terms, hence the computational efficiency is high. Finally, an exact solution is provided in a special case, and this corresponds to the analytical solutions obtained in the more general case. The approximate solutions agree qualitatively with the exact solutions. (paper)

  4. Research on a novel axial-flux magnetic-field-modulated brushless double-rotor machine with low axial force and high efficiency

    Directory of Open Access Journals (Sweden)

    Chengde Tong

    2017-05-01

    Full Text Available The axial-flux magnetic-field-modulated brushless double-rotor machine (MFM-BDRM is a possible alternative as a power-split device for hybrid electric vehicles (HEVs. However, the existence of large axial force may lead to assembly problems and rich inner air-gap harmonics could result in high PM loss and low efficiency. This paper proposes a novel axial-flux MFM-BDRM with improved PM rotor structure. 2-D analytical method to predict the magnetic-field distribution of the proposed MFM-BDRM is developed and the design procedure of the proposed machine is illustrated. The impact of key geometrical parameters on axial force and torque is investigated. To evaluate the advantage of the proposed machine, a comparison is made with a conventional one with respect to electromagnetic performances. Results show that the proposed machine is effective in reducing PM eddy loss and axial force by 60% and 35%, respectively.

  5. Limb flexion-induced axial compression and bending in human femoropopliteal artery segments.

    Science.gov (United States)

    Poulson, William; Kamenskiy, Alexey; Seas, Andreas; Deegan, Paul; Lomneth, Carol; MacTaggart, Jason

    2018-02-01

    High failure rates of femoropopliteal artery (FPA) interventions are often attributed in part to severe mechanical deformations that occur with limb movement. Axial compression and bending of the FPA likely play significant roles in FPA disease development and reconstruction failure, but these deformations are poorly characterized. The goal of this study was to quantify axial compression and bending of human FPAs that are placed in positions commonly assumed during the normal course of daily activities. Retrievable nitinol markers were deployed using a custom-made catheter system into 28 in situ FPAs of 14 human cadavers. Contrast-enhanced, thin-section computed tomography images were acquired with each limb in the standing (180 degrees), walking (110 degrees), sitting (90 degrees), and gardening (60 degrees) postures. Image segmentation and analysis allowed relative comparison of spatial locations of each intra-arterial marker to determine axial compression and bending using the arterial centerlines. Axial compression in the popliteal artery (PA) was greater than in the proximal superficial femoral artery (SFA) or the adductor hiatus (AH) segments in all postures (P = .02). Average compression in the SFA, AH, and PA ranged from 9% to 15%, 11% to 19%, and 13% to 25%, respectively. The FPA experienced significantly more acute bending in the AH and PA segments compared with the proximal SFA (P < .05) in all postures. In the walking, sitting, and gardening postures, average sphere radii in the SFA, AH, and PA ranged from 21 to 27 mm, 10 to 18 mm, and 8 to 19 mm, whereas bending angles ranged from 150 to 157 degrees, 136 to 147 degrees, and 137 to 148 degrees, respectively. The FPA experiences significant axial compression and bending during limb flexion that occur at even modest limb angles. Moreover, different segments of the FPA appear to undergo significantly different degrees of deformation. Understanding the effects of limb flexion on axial compression and

  6. Diagnostic value of axial CT scan

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1983-01-01

    Axial CT scan was used to investigate the radiological details of the temporal bone of 33 patients with chronic otitis media, secondary cholesteatoma, sensorineural hearing loss, Meniere disease, vertigo, facial spasm, and neoplasma. The axial scans showed anatomic details of the temporal bone, and at the same time clearly demonstrated the extent of the soft-tissue masses in the middle ears, as well as the destructions of the ossicles. Bone changes of the anterior walls of the epitympanum and external auditory meatus were more clearly demonstrated than by coronary CT scan. However, the axial scan had the disadvantages in demonstrating the stapes, crista transversa, and the mastoid portion of the facial canal. (author)

  7. Improving the lattice axial vector current

    International Nuclear Information System (INIS)

    Horsley, R.; Perlt, H.; Schiller, A.; Zanotti, J.M.

    2015-11-01

    For Wilson and clover fermions traditional formulations of the axial vector current do not respect the continuum Ward identity which relates the divergence of that current to the pseudoscalar density. Here we propose to use a point-split or one-link axial vector current whose divergence exactly satisfies a lattice Ward identity, involving the pseudoscalar density and a number of irrelevant operators. We check in one-loop lattice perturbation theory with SLiNC fermion and gauge plaquette action that this is indeed the case including order O(a) effects. Including these operators the axial Ward identity remains renormalisation invariant. First preliminary results of a nonperturbative check of the Ward identity are also presented.

  8. Adverse events during CT colonography for screening, diagnosis and preoperative staging of colorectal cancer: a Japanese national survey

    Energy Technology Data Exchange (ETDEWEB)

    Nagata, Koichi [Japanese Society of Gastrointestinal Cancer Screening, Committee for Quality Assessment of Colorectal Cancer Screening, Tokyo (Japan); Gastrointestinal Advanced Imaging Academy, Tochigi (Japan); National Cancer Centre, Division of Screening Technology, Centre for Public Health Sciences, Tokyo (Japan); Takabayashi, Ken [Gastrointestinal Advanced Imaging Academy, Tochigi (Japan); National Cancer Centre, Division of Screening Technology, Centre for Public Health Sciences, Tokyo (Japan); Hokkaido Gastroenterology Hospital, Department of Radiology, Sapporo (Japan); Yasuda, Takaaki [Gastrointestinal Advanced Imaging Academy, Tochigi (Japan); National Cancer Centre, Division of Screening Technology, Centre for Public Health Sciences, Tokyo (Japan); Nagasaki Kamigoto Hospital, Department of Radiology, Nagasaki (Japan); Hirayama, Michiaki [Gastrointestinal Advanced Imaging Academy, Tochigi (Japan); Tonan Hospital, Department of Gastroenterology, Sapporo (Japan); Endo, Shungo [Gastrointestinal Advanced Imaging Academy, Tochigi (Japan); Fukushima Medical University, Department of Coloproctology, Aizu Medical Centre, Aizu-Wakamatsu, Fukushima (Japan); Nozaki, Ryoichi [Japanese Society of Gastrointestinal Cancer Screening, Committee for Quality Assessment of Colorectal Cancer Screening, Tokyo (Japan); Gastrointestinal Advanced Imaging Academy, Tochigi (Japan); Takano Hospital, Coloproctology Centre, Kumamoto (Japan); Shimada, Takenobu [Japanese Society of Gastrointestinal Cancer Screening, Committee for Quality Assessment of Colorectal Cancer Screening, Tokyo (Japan); Cancer Detection Centre of the Miyagi Cancer Society, Sendai, Miyagi (Japan); Kanazawa, Hidenori [National Cancer Centre, Division of Screening Technology, Centre for Public Health Sciences, Tokyo (Japan); Jichi Medical University, Department of Radiology, Shimotsuke, Tochigi (Japan); Fujiwara, Masanori [Gastrointestinal Advanced Imaging Academy, Tochigi (Japan); Kameda Medical Centre Makuhari, Radiology Section, Mihama-ku, Chiba (Japan); Shimizu, Norihito [Gastrointestinal Advanced Imaging Academy, Tochigi (Japan); Matsuoka Clinic, Radiology Section, Nara (Japan); Iwatsuki, Tatema [Gastrointestinal Advanced Imaging Academy, Tochigi (Japan); Matsuda Hospital, Radiology Section, Hamamatsu, Shizuoka (Japan); Iwano, Teruaki [Gastrointestinal Advanced Imaging Academy, Tochigi (Japan); Tokushima Kensei Hospital, Radiology Section, Tokushima (Japan); Saito, Hiroshi [Japanese Society of Gastrointestinal Cancer Screening, Committee for Quality Assessment of Colorectal Cancer Screening, Tokyo (Japan); National Cancer Centre, Division of Screening Assessment and Management, Centre for Public Health Sciences, Tokyo (Japan)

    2017-12-15

    To retrospectively evaluate the frequencies and magnitudes of adverse events associated with computed tomographic colonography (CTC) for screening, diagnosis and preoperative staging of colorectal cancer. A Japanese national survey on CTC was administered by use of an online survey tool in the form of a questionnaire. The questions covered mortality, colorectal perforation, vasovagal reaction, total number of examinations, and examination procedures. The survey data was collated and raw frequencies were determined. Fisher's exact test was used to determine differences in event rates between groups. At 431 institutions, 147,439 CTC examinations were performed. No deaths were reported. Colorectal perforations occurred in 0.014% (21/147,439): 0.003% (1/29,823) in screening, 0.014% (13/91,007) in diagnosis and 0.028% (7/25,330) in preoperative staging. The perforation risk was significantly lower in screening than in preoperative staging CTC procedures (p = 0.028). Eighty-one per cent of perforation cases (17/21) did not require emergency surgery. Vasovagal reaction occurred in 0.081% (120/147,439): 0.111% (33/29,823) in screening, 0.088% (80/91,007) in diagnosis and 0.028% (7/25,330) in preoperative staging. The risk of colorectal perforation and vasovagal reaction in CTC is low. The frequency of colorectal perforation associated with CTC is least in the screening group and greatest in the preoperative-staging group. (orig.)

  9. Adverse events during CT colonography for screening, diagnosis and preoperative staging of colorectal cancer: a Japanese national survey

    International Nuclear Information System (INIS)

    Nagata, Koichi; Takabayashi, Ken; Yasuda, Takaaki; Hirayama, Michiaki; Endo, Shungo; Nozaki, Ryoichi; Shimada, Takenobu; Kanazawa, Hidenori; Fujiwara, Masanori; Shimizu, Norihito; Iwatsuki, Tatema; Iwano, Teruaki; Saito, Hiroshi

    2017-01-01

    To retrospectively evaluate the frequencies and magnitudes of adverse events associated with computed tomographic colonography (CTC) for screening, diagnosis and preoperative staging of colorectal cancer. A Japanese national survey on CTC was administered by use of an online survey tool in the form of a questionnaire. The questions covered mortality, colorectal perforation, vasovagal reaction, total number of examinations, and examination procedures. The survey data was collated and raw frequencies were determined. Fisher's exact test was used to determine differences in event rates between groups. At 431 institutions, 147,439 CTC examinations were performed. No deaths were reported. Colorectal perforations occurred in 0.014% (21/147,439): 0.003% (1/29,823) in screening, 0.014% (13/91,007) in diagnosis and 0.028% (7/25,330) in preoperative staging. The perforation risk was significantly lower in screening than in preoperative staging CTC procedures (p = 0.028). Eighty-one per cent of perforation cases (17/21) did not require emergency surgery. Vasovagal reaction occurred in 0.081% (120/147,439): 0.111% (33/29,823) in screening, 0.088% (80/91,007) in diagnosis and 0.028% (7/25,330) in preoperative staging. The risk of colorectal perforation and vasovagal reaction in CTC is low. The frequency of colorectal perforation associated with CTC is least in the screening group and greatest in the preoperative-staging group. (orig.)

  10. On the axial anomalies in external tensor fields

    International Nuclear Information System (INIS)

    Khudaverdyan, O.M.; Mkrtchyan, R.L.; Zurabyan, L.A.

    1985-01-01

    Computation of the axial anomaly for Dirac fermions in external tensor fields is studied. The sequence of the supersymmetric one-dimensional models is presented. Their supercharges are equal, after quantization, to Dirac operators in external tensor fields, and the density of Witten's partition function gives the anomaly. It is shown that action in the corresponding path integral differs from the classical one. Gaussian approximation gives the anomaly only in the case of third-rank tensor with zero exterior derivative and in that case anomaly is calculated in all dimensions. The interpretation of that field as the torsion of gravitational field and also connection with the results of Witten and Alvarez-Gaume and Atiyah-Singer index theorem are discussed

  11. Axial tomographic scanner

    International Nuclear Information System (INIS)

    1976-01-01

    An axial tomographic system is described comprising axial tomographic means for collecting sets of data corresponding to the transmission or absorption of a number of beams of penetrating radiation through a planar slice of an object. It includes means to locate an object to be analyzed, a source and detector for directing one or more beams of penetrating radiation through the object from the source to the detector, and means to rotate (and optionally translate) the source as well as means to process the collected sets of data. Data collection, data processing, and data display can each be conducted independently of each other. An additional advantage of the system described is that the raw data (i.e., the originally collected data) are not destroyed by the data processing but instead are retained intact for further reference or use, if needed

  12. Δ(1232) Axial Charge and Form Factors from Lattice QCD

    International Nuclear Information System (INIS)

    Alexandrou, Constantia; Gregory, Eric B.; Korzec, Tomasz; Koutsou, Giannis; Negele, John W.; Sato, Toru; Tsapalis, Antonios

    2011-01-01

    We present the first calculation on the Δ axial vector and pseudoscalar form factors using lattice QCD. Two Goldberger-Treiman relations are derived and examined. A combined chiral fit is performed to the nucleon axial charge, N to Δ axial transition coupling constant and Δ axial charge.

  13. Pulmonary lobar volumetry using novel volumetric computer-aided diagnosis and computed tomography

    Science.gov (United States)

    Iwano, Shingo; Kitano, Mariko; Matsuo, Keiji; Kawakami, Kenichi; Koike, Wataru; Kishimoto, Mariko; Inoue, Tsutomu; Li, Yuanzhong; Naganawa, Shinji

    2013-01-01

    OBJECTIVES To compare the accuracy of pulmonary lobar volumetry using the conventional number of segments method and novel volumetric computer-aided diagnosis using 3D computed tomography images. METHODS We acquired 50 consecutive preoperative 3D computed tomography examinations for lung tumours reconstructed at 1-mm slice thicknesses. We calculated the lobar volume and the emphysematous lobar volume volumetry computer-aided diagnosis system could more precisely measure lobar volumes than the conventional number of segments method. Because semi-automatic computer-aided diagnosis and automatic computer-aided diagnosis were complementary, in clinical use, it would be more practical to first measure volumes by automatic computer-aided diagnosis, and then use semi-automatic measurements if automatic computer-aided diagnosis failed. PMID:23526418

  14. Compression response of tri-axially braided textile composites

    Science.gov (United States)

    Song, Shunjun

    2007-12-01

    This thesis is concerned with characterizing the compression stiffness and compression strength of 2D tri-axially braided textile composites (2DTBC). Two types of 2DTBC are considered differing only on the resin type, while the textile fiber architecture is kept the same with bias tows at 45 degrees to the axial tows. Experimental, analytical and computational methods are described based on the results generated in this study. Since these composites are manufactured using resin transfer molding, the intended and as manufactured composite samples differ in their microstructure due to consolidation and thermal history effects in the manufacturing cycle. These imperfections are measured and the effect of these imperfections on the compression stiffness and strength are characterized. Since the matrix is a polymer material, the nonuniform thermal history undergone by the polymer at manufacturing (within the composite and in the presence of fibers) renders its properties to be non-homogenous. The effects of these non-homogeneities are captured through the definition of an equivalent in-situ matrix material. A method to characterize the mechanical properties of the in-situ matrix is also described. Fiber tow buckling, fiber tow kinking and matrix microcracking are all observed in the experiments. These failure mechanisms are captured through a computational model that uses the finite element (FE) technique to discretize the structure. The FE equations are solved using the commercial software ABAQUS version 6.5. The fiber tows are modeled as transversely isotropic elastic-plastic solids and the matrix is modeled as an isotropic elastic-plastic solid with and without microcracking damage. Because the 2DTBC is periodic, the question of how many repeat units are necessary to model the compression stiffness and strength are examined. Based on the computational results, the correct representative unit cell for this class of materials is identified. The computational models and

  15. Axial force measurement for esophageal function testing

    DEFF Research Database (Denmark)

    Gravesen, Flemming Holbæk; Funch-Jensen, Peter; Gregersen, Hans

    2009-01-01

    force (force in radial direction) whereas the bolus moves along the length of esophagus in a distal direction. Force measurements in the longitudinal (axial) direction provide a more direct measure of esophageal transport function. The technique used to record axial force has developed from external...... force transducers over in-vivo strain gauges of various sizes to electrical impedance based measurements. The amplitude and duration of the axial force has been shown to be as reliable as manometry. Normal, as well as abnormal, manometric recordings occur with normal bolus transit, which have been...... documented using imaging modalities such as radiography and scintigraphy. This inconsistency using manometry has also been documented by axial force recordings. This underlines the lack of information when diagnostics are based on manometry alone. Increasing the volume of a bag mounted on a probe...

  16. Do Routine Preoperative and Intraoperative Urine Cultures Benefit Pediatric Vesicoureteral Reflux Surgery?

    Directory of Open Access Journals (Sweden)

    Daniel R. Hettel

    2017-01-01

    Full Text Available Objective. To determine if routine preoperative and intraoperative urine cultures (UCx are necessary in pediatric vesicoureteral (VUR reflux surgery by identifying their association with each other, preoperative symptoms, and surgical outcomes. Materials and Methods. A retrospective review of patients undergoing ureteral reimplant(s for primary VUR at a tertiary academic medical center between years 2000 and 2014 was done. Preoperative UCx were defined as those within 30 days before surgery. A positive culture was defined as >50,000 colony forming units of a single organism. Results. A total of 185 patients were identified and 87/185 (47.0% met inclusion criteria. Of those, 39/87 (45% completed a preoperative UCx. Only 3/39 (8% preoperative cultures returned positive, and all of those patients were preoperatively symptomatic. No preoperatively asymptomatic patients had positive preoperative cultures. Intraoperative cultures were obtained in 21/87 (24.1% patients; all were negative. No associations were found between preoperative culture results and intraoperative cultures or between culture result and postoperative complications. Conclusions. In asymptomatic patients, no associations were found between the completion of a preoperative or intraoperative UCx and surgical outcomes, suggesting that not all patients may require preoperative screening. Children presenting with symptoms of urinary tract infection (UTI prior to ureteral reimplantation may benefit from preoperative UCx.

  17. Aerodynamic modelling and optimization of axial fans

    Energy Technology Data Exchange (ETDEWEB)

    Noertoft Soerensen, Dan

    1998-01-01

    A numerically efficient mathematical model for the aerodynamics of low speed axial fans of the arbitrary vortex flow type has been developed. The model is based on a blade-element principle, whereby the rotor is divided into a number of annular stream tubes. For each of these stream tubes relations for velocity, pressure and radial position are derived from the conservation laws for mass, tangential momentum and energy. The equations are solved using the Newton-Raphson methods, and solutions converged to machine accuracy are found at small computing costs. The model has been validated against published measurements on various fan configurations, comprising two rotor-only fan stages, a counter-rotating fan unit and a stator-rotor stator stage. Comparisons of local and integrated properties show that the computed results agree well with the measurements. Optimizations have been performed to maximize the mean value of fan efficiency in a design interval of flow rates, thus designing a fan which operates well over a range of different flow conditions. The optimization scheme was used to investigate the dependence of maximum efficiency on 1: the number of blades, 2: the width of the design interval and 3: the hub radius. The degree of freedom in the choice of design variable and constraints, combined with the design interval concept, provides a valuable design-tool for axial fans. To further investigate the use of design optimization, a model for the vortex shedding noise from the trailing edge of the blades has been incorporated into the optimization scheme. The noise emission from the blades was minimized in a flow rate design point. Optimizations were performed to investigate the dependence of the noise on 1: the number of blades, 2: a constraint imposed on efficiency and 3: the hub radius. The investigations showed, that a significant reduction of noise could be achieved, at the expense of a small reduction in fan efficiency. (EG) 66 refs.

  18. Effects of axial gap and nozzle distribution on aerodynamic forces of a supersonic partial-admission turbine

    Directory of Open Access Journals (Sweden)

    Jinpeng JIANG

    2017-12-01

    Full Text Available The turbine in an LH2/LOX rocket engine is designed as a two-stage supersonic partial-admission turbine. Three-dimensional steady and unsteady simulations were conducted to analyze turbine performance and aerodynamic forces on rotor blades. Different configurations were employed to investigate the effects of the axial gap and nozzle distribution on the predicted performance and aerodynamic forces. Rotor blades experience unsteady aerodynamic forces because of the partial admission. Aerodynamic forces show periodicity in the admission region, and are close to zero after leaving the admission region. The unsteady forces in frequency domain indicate that components exist in a wide frequency region, and the admission passing frequency is dominant. Those multiples of the rotational frequency which are multiples of the nozzle number in a full-admission turbine are notable components. Results show that the turbine efficiency decreases as the axial gap between nozzles and the 1st stage rotor (rotor 1 increases. Fluctuation of the circumferential aerodynamic force on rotor 1 blades decreases with the axial gap increasing. The turbine efficiency decreases as the circumferential spacing between nozzles increases. Fluctuations of the circumferential and axial aerodynamic forces increase as the circumferential spacing increases. As for the non-equidistant nozzle distribution, it produces similar turbine performance and amplitude-frequency characteristics of forces to those of the normal configuration, when the mean spacing is equal to that of the normal case. Keywords: Aerodynamic force, Axial gap, Computational fluid dynamics (CFD, Nozzle distribution, Partial admission, Turbine

  19. Two-dimensional nonlinear dynamics of an axially moving viscoelastic beam with time-dependent axial speed

    International Nuclear Information System (INIS)

    Ghayesh, Mergen H.; Amabili, Marco; Farokhi, Hamed

    2013-01-01

    In the present study, the coupled nonlinear dynamics of an axially moving viscoelastic beam with time-dependent axial speed is investigated employing a numerical technique. The equations of motion for both the transverse and longitudinal motions are obtained using Newton’s second law of motion and the constitutive relations. A two-parameter rheological model of the Kelvin–Voigt energy dissipation mechanism is employed in the modelling of the viscoelastic beam material, in which the material time derivative is used in the viscoelastic constitutive relation. The Galerkin method is then applied to the coupled nonlinear equations, which are in the form of partial differential equations, resulting in a set of nonlinear ordinary differential equations (ODEs) with time-dependent coefficients due to the axial acceleration. A change of variables is then introduced to this set of ODEs to transform them into a set of first-order ordinary differential equations. A variable step-size modified Rosenbrock method is used to conduct direct time integration upon this new set of first-order nonlinear ODEs. The mean axial speed and the amplitude of the speed variations, which are taken as bifurcation parameters, are varied, resulting in the bifurcation diagrams of Poincaré maps of the system. The dynamical characteristics of the system are examined more precisely via plotting time histories, phase-plane portraits, Poincaré sections, and fast Fourier transforms (FFTs)

  20. Shaping of the axial power density distribution in the core to minimize the vapor volume fraction at the outlet of the VVER-1200 fuel assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Savander, V. I.; Shumskiy, B. E., E-mail: borisshumskij@yandex.ru [National Research Nuclear University MEPhI (Russian Federation); Pinegin, A. A. [National Research Center Kurchatov Institute (Russian Federation)

    2016-12-15

    The possibility of decreasing the vapor fraction at the VVER-1200 fuel assembly outlet by shaping the axial power density field is considered. The power density field was shaped by axial redistribution of the concentration of the burnable gadolinium poison in the Gd-containing fuel rods. The mathematical modeling of the VVER-1200 core was performed using the NOSTRA computer code.

  1. Avoiding preoperative breast MRI when conventional imaging is sufficient to stage patients eligible for breast conserving therapy

    Energy Technology Data Exchange (ETDEWEB)

    Pengel, Kenneth E., E-mail: k.pengel@nki.nl [Department of Radiology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Loo, Claudette E. [Department of Radiology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Wesseling, Jelle [Department of Pathology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Pijnappel, Ruud M. [Department of Radiology/Image Sciences Institute, University Medical Center Utrecht Heidelberglaan 100, 3584 CX Utrecht (Netherlands); Rutgers, Emiel J.Th. [Department of Surgical Oncology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Gilhuijs, Kenneth G.A. [Department of Radiology, The Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Department of Radiology/Image Sciences Institute, University Medical Center Utrecht Heidelberglaan 100, 3584 CX Utrecht (Netherlands)

    2014-02-15

    Aim: To determine when preoperative breast MRI will not be more informative than available breast imaging and can be omitted in patients eligible for breast conserving therapy (BCT). Methods: We performed an MRI in 685 consecutive patients with 692 invasive breast tumors and eligible for BCT based on conventional imaging and clinical examination. We explored associations between patient, tumor, and conventional imaging characteristics and similarity with MRI findings. Receiver operating characteristic (ROC) analysis was employed to compute the area under the curve (AUC). Results: MRI and conventional breast imaging were similar in 585 of the 692 tumors (85%). At univariate analysis, age (p < 0.001), negative preoperative lymph node status (p = 0.011), comparable tumor diameter at mammography and at ultrasound (p = 0.001), negative HER2 status (p = 0.044), and absence of invasive lobular cancer (p = 0.005) were significantly associated with this similarity. At multivariate analysis, these factors, except HER2 status, retained significant associations. The AUC was 0.68. Conclusions: It is feasible to identify a subgroup of patients prior to preoperative breast MRI, who will most likely show similar results on conventional imaging as on MRI. These findings enable formulation of a practical consensus guideline to determine in which patients a preoperative breast MRI can be omitted.

  2. Avoiding preoperative breast MRI when conventional imaging is sufficient to stage patients eligible for breast conserving therapy

    International Nuclear Information System (INIS)

    Pengel, Kenneth E.; Loo, Claudette E.; Wesseling, Jelle; Pijnappel, Ruud M.; Rutgers, Emiel J.Th.; Gilhuijs, Kenneth G.A.

    2014-01-01

    Aim: To determine when preoperative breast MRI will not be more informative than available breast imaging and can be omitted in patients eligible for breast conserving therapy (BCT). Methods: We performed an MRI in 685 consecutive patients with 692 invasive breast tumors and eligible for BCT based on conventional imaging and clinical examination. We explored associations between patient, tumor, and conventional imaging characteristics and similarity with MRI findings. Receiver operating characteristic (ROC) analysis was employed to compute the area under the curve (AUC). Results: MRI and conventional breast imaging were similar in 585 of the 692 tumors (85%). At univariate analysis, age (p < 0.001), negative preoperative lymph node status (p = 0.011), comparable tumor diameter at mammography and at ultrasound (p = 0.001), negative HER2 status (p = 0.044), and absence of invasive lobular cancer (p = 0.005) were significantly associated with this similarity. At multivariate analysis, these factors, except HER2 status, retained significant associations. The AUC was 0.68. Conclusions: It is feasible to identify a subgroup of patients prior to preoperative breast MRI, who will most likely show similar results on conventional imaging as on MRI. These findings enable formulation of a practical consensus guideline to determine in which patients a preoperative breast MRI can be omitted

  3. Conversion from laparoscopic to open cholecystectomy: Multivariate analysis of preoperative risk factors

    Directory of Open Access Journals (Sweden)

    Khan M

    2005-01-01

    Full Text Available BACKGROUND: Laparoscopic cholecystectomy has become the gold standard in the treatment of symptomatic cholelithiasis. Some patients require conversion to open surgery and several preoperative variables have been identified as risk factors that are helpful in predicting the probability of conversion. However, there is a need to devise a risk-scoring system based on the identified risk factors to (a predict the risk of conversion preoperatively for selected patients, (b prepare the patient psychologically, (c arrange operating schedules accordingly, and (d minimize the procedure-related cost and help overcome financial constraints, which is a significant problem in developing countries. AIM: This study was aimed to evaluate preoperative risk factors for conversion from laparoscopic to open cholecystectomy in our setting. SETTINGS AND DESIGNS: A case control study of patients who underwent laparoscopic surgery from January 1997 to December 2001 was conducted at the Aga Khan University Hospital, Karachi, Pakistan. MATERIALS AND METHODS: All those patients who were converted to open surgery (n = 73 were enrolled as cases. Two controls who had successful laparoscopic surgery (n = 146 were matched with each case for operating surgeon and closest date of surgery. STATISTICAL ANALYSIS USED: Descriptive statistics were computed and, univariate and multivariate analysis was done through multiple logistic regression. RESULTS: The final multivariate model identified two risk factors for conversion: ultrasonographic signs of inflammation (adjusted odds ratio [aOR] = 8.5; 95% confidence interval [CI]: 3.3, 21.9 and age > 60 years (aOR = 8.1; 95% CI: 2.9, 22.2 after adjusting for physical signs, alkaline phosphatase and BMI levels. CONCLUSION: Preoperative risk factors evaluated by the present study confirm the likelihood of conversion. Recognition of these factors is important for understanding the characteristics of patients at a higher risk of conversion.

  4. A retrospective analysis of preoperative staging modalities for oral squamous cell carcinoma.

    Science.gov (United States)

    Kähling, Ch; Langguth, T; Roller, F; Kroll, T; Krombach, G; Knitschke, M; Streckbein, Ph; Howaldt, H P; Wilbrand, J-F

    2016-12-01

    An accurate preoperative assessment of cervical lymph node status is a prerequisite for individually tailored cancer therapies in patients with oral squamous cell carcinoma. The detection of malignant spread and its treatment crucially influence the prognosis. The aim of the present study was to analyze the different staging modalities used among patients with a diagnosis of primary oral squamous cell carcinoma between 2008 and 2015. An analysis of preoperative staging findings, collected by clinical palpation, ultrasound, and computed tomography (CT), was performed. The results obtained were compared with the results of the final histopathological findings of the neck dissection specimens. A statistical analysis using McNemar's test was performed. The sensitivity of CT for the detection of malignant cervical tumor spread was 74.5%. The ultrasound obtained a sensitivity of 60.8%. Both CT and ultrasound demonstrated significantly enhanced sensitivity compared to the clinical palpation with a sensitivity of 37.1%. No significant difference was observed between CT and ultrasound. A combination of different staging modalities increased the sensitivity significantly compared with ultrasound staging alone. No significant difference in sensitivity was found between the combined use of different staging modalities and CT staging alone. The highest sensitivity, of 80.0%, was obtained by a combination of all three staging modalities: clinical palpation, ultrasound and CT. The present study indicates that CT has an essential role in the preoperative staging of patients with oral squamous cell carcinoma. Its use not only significantly increases the sensitivity of cervical lymph node metastasis detection but also offers a preoperative assessment of local tumor spread and resection borders. An additional non-invasive cervical lymph node examination increases the sensitivity of the tumor staging process and reduces the risk of occult metastasis. Copyright © 2016 European

  5. Stochastic quantization for the axial model

    International Nuclear Information System (INIS)

    Farina, C.; Montani, H.; Albuquerque, L.C.

    1991-01-01

    We use bosonization ideas to solve the axial model in the stochastic quantization framework. We obtain the fermion propagator of the theory decoupling directly the Langevin equation, instead of the Fokker-Planck equation. In the Appendix we calculate explicitly the anomalous divergence of the axial-vector current by using a regularization that does not break the Markovian character of the stochastic process

  6. Nonperturbative Aspects of Axial Vector Vertex

    Institute of Scientific and Technical Information of China (English)

    ZONG Hong-Shi; CHEN Xiang-Song; WANG Fan; CHANG Chao-Hsi; ZHAO En-Guang

    2002-01-01

    It is shown how the axial vector current of current quarks is related to that of constituent quarks within the framework of the global color symmetry model.Gluon dressing of the axial vector vertex and the quark self-energy functions are described by the inhomogeneous Bethe-Salpeter equation in the ladder approximation and the Schwinger Dyson equation in the rainbow approximation,respectively.

  7. Determination of axial profit performed burnup credit by SCALE 4.3-system

    International Nuclear Information System (INIS)

    Miro, R.; Verdu, G.; Munoz-Cobo, J. L.

    1998-01-01

    SCALE 4.3 is a modular code system designed for realizing standard computational analysis for licensing evaluation. Since now, spent fuel storage pools criticality analysis have been done considering this fuel as fresh, with its maximum enrichment. With burnup credit we can obtain cheaper and compact configurations. The procedure for calculating a spent fuel storage consists of a burnup calculation plus a criticality calculation. We can perform a conservative approximation for the burnup calculations using 1-D results, but, besides the geometry configurations for the 3-D criticality calculation. we need an appropriate approximation to model the burnup axial variation. We assume that for a burnup profile set, the most conservative profile is between the lower and the upper range of this profile, set. We consider only combinations of the maximum and minimum burnup in each axial region, for each burnup range. This gives an estimation of the different burnup shapes effect and the general characteristics of the most conservative shape. (Author) 6 refs

  8. Optimal ancilla-free Pauli+V circuits for axial rotations

    International Nuclear Information System (INIS)

    Blass, Andreas; Bocharov, Alex; Gurevich, Yuri

    2015-01-01

    We address the problem of optimal representation of single-qubit rotations in a certain unitary basis consisting of the so-called V gates and Pauli matrices. The V matrices were proposed by Lubotsky, Philips, and Sarnak [Commun. Pure Appl. Math. 40, 401–420 (1987)] as a purely geometric construct in 1987 and recently found applications in quantum computation. They allow for exceptionally simple quantum circuit synthesis algorithms based on quaternionic factorization. We adapt the deterministic-search technique initially proposed by Ross and Selinger to synthesize approximating Pauli+V circuits of optimal depth for single-qubit axial rotations. Our synthesis procedure based on simple SL 2 (ℤ) geometry is almost elementary

  9. Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    De Silva, Nathalia Cristine; Junqueira, Jose Luiz Cinta; Panzarella, Francine Keuhi; Raitz, Ricardo [Sao Leopoldo Mandic Research Center, Dept. of Oral Radiology, College of Dentistry, Sao Paulo (Brazil); Brriviera, Mauricio [Dept. of Oral Radiology, College of Dentistry, Catholic University of Brasilia, Sao Paulo (Brazil)

    2017-03-15

    This study was performed to investigate the intra- and inter-observer variability in linear measurements with axial images obtained by PreXion (PreXion Inc., San Mateo, USA) and i-CAT (Imaging Sciences International, Xoran Technologies Inc., Hatfield, USA) CBCT scanners, with different voxel sizes. A cylindrical object made from nylon with radiopaque markers (phantom) was scanned by i-CAT and PreXion 3D devices. For each axial image, measurements were taken twice in the horizontal (distance A-B) and vertical (distance C-D) directions, randomly, with a one-week interval between measurements, by four oral radiologists with five years or more experience in the use of these measuring tools. All of the obtained linear measurements had lower values than those of the phantom. The statistical analysis showed high intra- and inter-observer reliability (p=0.297). Compared to the real measurements, the measurements obtained using the i-CAT device and PreXion tomography, on average, revealed absolute errors ranging from 0.22 to 0.59 mm and from 0.23 to 0.63 mm, respectively. It can be concluded that both scanners are accurate, although the linear measurements are underestimations, with no significant differences between the evaluators.

  10. Conservative axial burnup distributions for actinide-only burnup credit

    International Nuclear Information System (INIS)

    Kang, C.; Lancaster, D.

    1997-11-01

    Unlike the fresh fuel approach, which assumes the initial isotopic compositions for criticality analyses, any burnup credit methodology must address the proper treatment of axial burnup distributions. A straightforward way of treating a given axial burnup distribution is to segment the fuel assembly into multiple meshes and to model each burnup mesh with the corresponding isotopic compositions. Although this approach represents a significant increase in modeling efforts compared to the uniform average burnup approach, it can adequately determine the reactivity effect of the axial burnup distribution. A major consideration is what axial burnup distributions are appropriate for use in light of many possible distributions depending on core operating conditions and histories. This paper summarizes criticality analyses performed to determine conservative axial burnup distributions. The conservative axial burnup distributions presented in this paper are included in the Topical Report on Actinide-Only Burnup Credit for Pressurized Water Reactor Spent Nuclear Fuel Packages, Revision 1 submitted in May 1997 by the US Department of Energy (DOE) to the US Nuclear Regulatory Commission (NRC). When approved by NRC, the conservative axial burnup distributions may be used to model PWR spent nuclear fuel for the purpose of gaining actinide only burnup credit

  11. Cycle counting procedure for fatigue failure preditions for complicated multi-axial stress histories

    International Nuclear Information System (INIS)

    Jones, D.P.; Friedrich, C.M.; Hoppe, R.G.

    1977-12-01

    A procedure has been developed to determine the cumulative fatigue damage in structures experiencing complicated multi-axial stress histories. The procedure is a generalization of the rainflow method developed by Matsuishi and Endo for one-dimensional situations. It provides a consistent treatment of three-dimensional stress states that is especially suited to computer programming applications for the post-processing of finite element stress data. The procedure includes a unique method to account for the rotation of principal stresses with time during the stress history and for the cumulative fatigue damage resulting from partial stress reversals within a stress cycle. The general procedure and necessary equations for programming are presented. Comparisons are made with life predictions using Section III of the ASME Boiler and Pressure Vessel Code for two hypothetical multi-axial stress histories for which the principal stresses are rotating with time. These comparisons show that the cycle counting method provides a consistent unambiguous interpretation of the fatigue design procedure in the ASME Code for these cases. Finally, the fatigue life of a perforated plate, as analyzed by finite elements, is computed for the combination of several hypothetical stress histories. This example demonstrates the utility of the proposed method when used in conjunction with finite element programs

  12. Preoperative study of the surface ECG for the prognosis of atrial fibrillation maze surgery outcome at discharge

    International Nuclear Information System (INIS)

    Hernández, Antonio; Rieta, José Joaquín; Alcaraz, Raúl; Hornero, Fernando

    2014-01-01

    The Cox-maze surgery is an effective procedure for terminating atrial fibrillation (AF) in patients requiring open-heart surgery associated with another heart disease. After the intervention, regardless of the patient's rhythm, all are treated with oral anticoagulants and antiarrhythmic drugs prior to discharge. Furthermore, patients maintaining AF before discharge could also be treated with electrical cardioversion (ECV). In view of this, a preoperative prognosis of the patient's rhythm at discharge would be helpful for optimizing drug therapy planning as well as for advancing ECV therapy. This work analyzes 30 preoperative electrocardiograms (ECGs) from patients suffering from AF in order to predict the Cox-maze surgery outcome at discharge. Two different characteristics of the AF pattern have been studied. On the one hand, the atrial activity (AA) organization, which provides information about the number of propagating wavelets in the atria, was investigated. AA organization has been successfully used in previous studies related to spontaneous reversion of paroxysmal AF and to the outcome of ECV. To assess organization, the dominant atrial frequency (DAF) and sample entropy (SampEn) have been computed. On the other hand, the second characteristic studied was the fibrillatory wave (f-wave) amplitude, which has been demonstrated to be a valuable indicator of the Cox-maze surgery outcome in previous studies. Moreover, this parameter has been obtained through a new methodology, based on computing the f-wave average power (fWP). Finally, all the computed indices were combined in a decision tree in order to improve prediction capability. Results for the DAF yielded a sensitivity (Se), a specificity (Sp) and an accuracy (Acc) of 61.54%, 82.35% and 73.33%, respectively. For SampEn the values were 69.23%, 76.00% and 73.33%, respectively, and for fWP they were 92.31%, 82.35% and 86.67%, respectively. Finally, the decision tree combining the three parameters

  13. [Indication for limited surgery on small lung cancer tumors measuring 1cm or less in diameter on preoperative computed tomography and long-term results].

    Science.gov (United States)

    Togashi, K; Koike, T; Emura, I; Usuda, H

    2008-07-01

    Non-invasive lung cancers showed a good prognosis after limited surgery. But it is still uncertain about invasive lung cancers. We investigated the indications for limited surgery for small lung cancer tumors measuring 1 cm or less in diameter on preoperative computed tomography (CT). This study retrospectively analyzed of 1,245 patients who underwent complete resection of lung cancer between 1989 and 2004 in our hospital. Sixty-two patients (5%) had tumors measuring 1 cm or less in diameter. The probability of survival was calculated using the Kaplan-Meier method. All diseases were detected by medical checkup, 52 % of the patients were not definitively diagnosed with lung cancer before surgery. Adenocarcinoma was histologically diagnosed in 49 patients (79%). Other histologic types included squamous cell carcinoma (8), large cell carcinoma (1), small cell carcinoma (1), carcinoid (2), and adenosquamous cell carcinoma (1). Fifty-seven patients (92%) showed pathologic stage IA. The other stages were IB (2), IIA (1), and IIIB (2). There were 14 bronchioloalveolar carcinomas (25% of IA diseases). The 5-year survival rates of IA patients were 90%. The 5-year survival rate of patients with tumors measuring 1cm or less diameter was 91% after lobectomy or pneumonectomy, and 90% after wedge resection or segmentectomy. There were 3 deaths from cancer recurrence, while there were no deaths in 14 patients with bronchioloalveolar carcinoma After limited surgery, non-invasive cancer showed good long-term results, while invasive cancer showed a recurrence rate of 2.3% to 79% even though the tumor measured 1 cm or less in diameter on preoperative CT.

  14. Preoperative differentiation between T1a and ≥T1b gallbladder cancer: combined interpretation of high-resolution ultrasound and multidetector-row computed tomography

    International Nuclear Information System (INIS)

    Joo, Ijin; Baek, Jee Hyun; Kim, Jung Hoon; Han, Joon Koo; Choi, Byung Ihn; Lee, Jae Young; Park, Hee Sun

    2014-01-01

    To determine the diagnostic value of combined interpretation of high-resolution ultrasound (HRUS) and multidetector-row computed tomography (MDCT) for preoperative differentiation between T1a and ≥T1b gallbladder (GB) cancer. Eighty-seven patients with pathologically confirmed GB cancers (T1a, n = 15; ≥T1b, n = 72), who preoperatively underwent both HRUS and MDCT, were included in this retrospective study. Two reviewers independently determined the T-stages of the GB cancers on HRUS and MDCT using a five-point confidence scale (5, definitely T1a; 1, definitely ≥T1b). For individual modality interpretation, the lesions with scores ≥4 were classified as T1a, and, for combined modality interpretation, the lesions with all scores ≥4 in both modalities were classified as T1a. The McNemar test was used to compare diagnostic performance. The diagnostic accuracy of differentiation between T1a and ≥T1b GB cancer was higher using combined interpretation (90.8 % and 88.5 % for reviewers 1 and 2, respectively) than individual interpretation of HRUS (82.8 % and 83.9 %) or MDCT (74.7 % and 82.8 %) (P < 0.05, reviewer 1). Combined interpretations demonstrated 100 % specificity for both reviewers, which was significantly higher than individual interpretations (P < 0.05, both reviewers). Combined HRUS and MDCT interpretation may improve the diagnostic accuracy and specificity for differentiating between T1a and ≥T1b GB cancers. circle Differentiating between T1a and ≥T1b gallbladder cancer can help surgical planning. (orig.)

  15. Recent advances in the reconstruction of cranio-maxillofacial defects using computer-aided design/computer-aided manufacturing.

    Science.gov (United States)

    Oh, Ji-Hyeon

    2018-12-01

    With the development of computer-aided design/computer-aided manufacturing (CAD/CAM) technology, it has been possible to reconstruct the cranio-maxillofacial defect with more accurate preoperative planning, precise patient-specific implants (PSIs), and shorter operation times. The manufacturing processes include subtractive manufacturing and additive manufacturing and should be selected in consideration of the material type, available technology, post-processing, accuracy, lead time, properties, and surface quality. Materials such as titanium, polyethylene, polyetheretherketone (PEEK), hydroxyapatite (HA), poly-DL-lactic acid (PDLLA), polylactide-co-glycolide acid (PLGA), and calcium phosphate are used. Design methods for the reconstruction of cranio-maxillofacial defects include the use of a pre-operative model printed with pre-operative data, printing a cutting guide or template after virtual surgery, a model after virtual surgery printed with reconstructed data using a mirror image, and manufacturing PSIs by directly obtaining PSI data after reconstruction using a mirror image. By selecting the appropriate design method, manufacturing process, and implant material according to the case, it is possible to obtain a more accurate surgical procedure, reduced operation time, the prevention of various complications that can occur using the traditional method, and predictive results compared to the traditional method.

  16. Pre-operative pain and sensory function in groin hernia

    DEFF Research Database (Denmark)

    Aasvang, Eske K; Hansen, Jeanette B; Kehlet, Henrik

    2009-01-01

    BACKGROUND: Although persistent postherniotomy occurs in 5-10% of patients, pathogenic mechanisms remain debatable. Since pre-operative pain has been demonstrated to be a risk factor for persistent postherniotomy pain, pre-operative alterations in nociceptive function may be a potential pathogenic...... mechanism. AIMS: To investigate the correlation between pre-operative pain intensity and sensory functions in the groin hernia area. METHODS: Patients with unilateral groin hernia were examined preoperatively by quantitative sensory testing (thermal, mechanical, and pressure [detection and pain thresholds...... (7%), all whom experienced no pain or pain less than weekly. Only cool detection thresholds were significantly lower between the hernia vs. contralateral side (poperative groin hernia...

  17. The influence of the tangential velocity of inner rotating wall on axial velocity profile of flow through vertical annular pipe with rotating inner surface

    Directory of Open Access Journals (Sweden)

    Sharf Abdusalam M.

    2014-03-01

    Full Text Available In the oil and gas industries, understanding the behaviour of a flow through an annulus gap in a vertical position, whose outer wall is stationary whilst the inner wall rotates, is a significantly important issue in drilling wells. The main emphasis is placed on experimental (using an available rig and computational (employing CFD software investigations into the effects of the rotation speed of the inner pipe on the axial velocity profiles. The measured axial velocity profiles, in the cases of low axial flow, show that the axial velocity is influenced by the rotation speed of the inner pipe in the region of almost 33% of the annulus near the inner pipe, and influenced inversely in the rest of the annulus. The position of the maximum axial velocity is shifted from the centre to be nearer the inner pipe, by increasing the rotation speed. However, in the case of higher flow, as the rotation speed increases, the axial velocity is reduced and the position of the maximum axial velocity is skewed towards the centre of the annulus. There is a reduction of the swirl velocity corresponding to the rise of the volumetric flow rate.

  18. Preoperative planning of calcium deposit removal in calcifying tendinitis of the rotator cuff - possible contribution of computed tomography, ultrasound and conventional X-Ray.

    Science.gov (United States)

    Izadpanah, Kaywan; Jaeger, Martin; Maier, Dirk; Südkamp, Norbert P; Ogon, Peter

    2014-11-20

    The purpose of the present study was to investigate the accuracy of Ultrasound (US), conventional X-Ray (CX) and Computed Tomography (CT) to estimate the total count, localization, morphology and consistency of Calcium deposits (CDs) in the rotator cuff. US, CX and CT imaging was performed pre-operatively in 151 patients who underwent arthroscopic removal of CDs in the rotator cuff. In all procedures: (1) total CD counts were determined, (2) the CDs appearance in each image modality was correlated to the intraoperative consistency and (3) CDs were localized in their relation to the acromion using US, CX and CT. Using US158 CDs, using CT 188 CDs and using CX 164 CDs were identified. Reliable localization of the CDs was possible with all used diagnostic modalities. CT revealed 49% of the CDs to be septated, out of which 85% were uni- and 15% multiseptated. CX was not suitable for prediction of CDs consistency. US reliably predicted viscous-solid CDs consistency only when presenting with full sound extinction (PPV 84.6%) . CT had high positive and negative predictive values for detection of liquid-soft (PPV 92.9%) and viscous-solid (PPV 87.8%) CDs. US and CX are sufficient for preoperative planning of CD removal with regards to localization and prediction of consistency if the deposits present with full sound extinction. This is the case in the majority of the patients. However, in patients with missing sound extinction CT can be recommended if CDs consistency of the deposits should be determined. Satellite deposits or septations are regularly present, which is of importance if complete CD removal is aspired.

  19. The preoperative evaluation prevent the postoperative complications of thyroidectomy

    Directory of Open Access Journals (Sweden)

    Chien-Feng Huang

    2015-03-01

    Conclusions: The success of thyroid surgery depends on careful preoperative planning, including a preoperative neck ultrasound to determine the proximity of the nodule to the recurrent laryngeal nerve course, and the consideration of the type of anesthesia, adjuvant devices for intra-op monitoring of the RLN, and surgical modalities. Our results suggest that preoperative evaluation implementations are positively associated with strategy of surgery and postoperative hypocalcemia prevention.

  20. The Role of Fine Needle Aspiration in the Diagnosis of Parotid Gland Tumors: Correlation With Preoperative Computerized Tomography Tumor Size.

    Science.gov (United States)

    Ghantous, Yasmine; Naddaf, Raja; Barak, Michal; Abd-Elraziq, Murad; Abu Eln-Naaj, Imad

    2016-03-01

    The role of fine needle aspiration cytology (FNAC) in the diagnosis of parotid gland masses is still controversial, regarding its sensitivity and specificity that vary between 41% and 100% and between 86% and 100% respectively.The aim of this study was to identify the specificity and sensitivity of FNAC of parotid gland tumors in relation to the tumor size as characterized preoperatively by computer tomography. The medical files of 79 patients whom were referred to the MaxilloFacila Surgery Department, Rambam medical center, over a 10.5-year period (2000-2010) were analyzed retrospectively.The extensity of the operation was determined by the location of the tumor as presented in computed tomography (CT) radiography, and preoperative FNAC examination.The majority of the masses were located in the superficial lobe (88.52%), and only 11.48% of the patients were located in the deep lobe (8:1 ratio). FNAC results were nondiagnostic in 7 patients (8.86%), 62 patients were diagnosed as inflammatory and benign lesion in (78.48%), malignant tumors were diagnosed in 10 patients (12.65%).The sensitivity in our study was 90%, the specificity was 98%, positive predictive value was 90%, negative predictive value was 98%, and diagnostic accuracy was 88%. The positive predictive value was 90%, the negative predictive value was 98%.Analyzing the effect of the preoperative CT size upon the accuracy of the FNAC diagnosis, we found that lesion with preoperative CT size greater than 24 mm has a more accurate FNAC result (P = 0.034).

  1. CFD Simulation and Optimization of Very Low Head Axial Flow Turbine Runner

    Directory of Open Access Journals (Sweden)

    Yohannis Mitiku Tobo

    2015-10-01

    Full Text Available The main objective of this work is Computational Fluid Dynamics (CFD modelling, simulation and optimization of very low head axial flow turbine runner  to be used to drive  a centrifugal pump of turbine-driven pump. The ultimate goal of the optimization is to produce a power of 1kW at head less than 1m from flowing  river to drive centrifugal pump using mechanical coupling (speed multiplier gear directly. Flow rate, blade numbers, turbine rotational speed, inlet angle are parameters used in CFD modeling,  simulation and design optimization of the turbine runner. The computed results show that power developed by a turbine runner increases with increasing flow rate. Pressure inside the turbine runner increases with flow rate but, runner efficiency increases for some flow rate and almost constant thereafter. Efficiency and power developed by a runner drops quickly if turbine speed increases due to higher pressure losses and conversion of pressure energy to kinetic energy inside the runner. Increasing blade number increases power developed but, efficiency does not increase always. Efficiency increases for some blade number and drops down due to the fact that  change in direction of the relative flow vector at the runner exit, which decreases the net rotational momentum and increases the axial flow velocity.

  2. Design of Single Stage Axial Turbine with Constant Nozzle Angle Blading for Small Turbojet

    Science.gov (United States)

    Putra Adnan, F.; Hartono, Firman

    2018-04-01

    In this paper, an aerodynamic design of a single stage gas generator axial turbine for small turbojet engine is explained. As per design requirement, the turbine should be able to deliver power output of 155 kW at 0.8139 kg/s gas mass flow, inlet total temperature of 1200 K and inlet total pressure of 335330 Pa. The design phase consist of several steps, i.e.: determination of velocity triangles in 2D plane, 2D blading design and 3D flow analysis at design point using Computational Fluid Dynamics method. In the determination of velocity triangles, two conditions are applied: zero inlet swirl (i.e. the gas flow enter the turbine at axial direction) and constant nozzle angle design (i.e. the inlet and outlet angle of the nozzle blade are constant from root to tip). The 2D approach in cascade plane is used to specify airfoil type at root, mean and tip of the blade based on inlet and outlet flow conditions. The 3D approach is done by simulating the turbine in full configuration to evaluate the overall performance of the turbine. The observed parameters including axial gap, stagger angle, and tip clearance affect its output power. Based on analysis results, axial gap and stagger angle are positively correlated with output power up to a certain point at which the power decreases. Tip clearance, however, gives inversely correlation with output power.

  3. Numerical study about the effect of the low Reynolds number on the performance in an axial compressor

    International Nuclear Information System (INIS)

    Choi, Min Suk; Baek, Je Hyun; Chung, Hee Taeg; Oh, Seong Hwan; Ko, Han Young

    2008-01-01

    A three-dimensional computation was conducted to understand effects of the low Reynolds number on the performance in a low-speed axial compressor at the design condition. The low Reynolds number can originates from the change of the air density because it decreases along the altitude in the troposphere. The performance of the axial compressor such as the static pressure rise was diminished by the separation on the suction surface with full span and the boundary layer on the hub, which were caused by the low Reynolds number. The total pressure loss at the low Reynolds number was found to be greater than that at the reference Reynolds number at the region from the hub to 85% span. Total pressure loss was scrutinized through three major loss categories in a subsonic axial compressor such as the profile loss, the tip leakage loss and the endwall loss using Denton's loss model, and the effects of the low Reynolds number on the performance were analyzed in detail

  4. Numerical study about the effect of the low Reynolds number on the performance in an axial compressor

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Min Suk; Baek, Je Hyun [Pohang University of Science and Technology, Pohang (Korea, Republic of); Chung, Hee Taeg [Gyeongsang National University, Jinju (Korea, Republic of); Oh, Seong Hwan; Ko, Han Young [Agency for Defense Development, Daejeon (Korea, Republic of)

    2008-02-15

    A three-dimensional computation was conducted to understand effects of the low Reynolds number on the performance in a low-speed axial compressor at the design condition. The low Reynolds number can originates from the change of the air density because it decreases along the altitude in the troposphere. The performance of the axial compressor such as the static pressure rise was diminished by the separation on the suction surface with full span and the boundary layer on the hub, which were caused by the low Reynolds number. The total pressure loss at the low Reynolds number was found to be greater than that at the reference Reynolds number at the region from the hub to 85% span. Total pressure loss was scrutinized through three major loss categories in a subsonic axial compressor such as the profile loss, the tip leakage loss and the endwall loss using Denton's loss model, and the effects of the low Reynolds number on the performance were analyzed in detail.

  5. Anterior mediastinal paraganglioma: A case for preoperative embolization

    Directory of Open Access Journals (Sweden)

    Shakir Murtaza

    2012-07-01

    Full Text Available Abstract Background Paraganglioma is a rare but highly vascular tumor of the anterior mediastinum. Surgical resection is a challenge owing to the close proximity to vital structures including the heart, trachea and great vessels. Preoperative embolization has been reported once to facilitate surgical treatment. Case presentation We report a case of anterior mediastinal paraganglioma that was embolized preoperatively, and was resected without the need for cardiopulmonary bypass and without major bleeding complications. Conclusion We make a case to further the role of preoperative embolization in the treatment of mediastinal paragangliomas.

  6. Development of submersible axial pump for wastewater

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Jeong Eui [Kangwon Nat' l Univ., Chuncheon (Korea, Republic of)

    2013-02-15

    This study was performed to develop a high efficiency submersible axial pump for concentration wastewater treatment. To do this, we simulated the effect of some parameters such as the axial twist angle of a blade({beta}), the radial twist angle of a blade({alpha}) and the length of a blade ({iota}) on pump efficiency using commercial code, ANSYS CFX and BladeGen. The results showed that the axial twist angle of a blade({beta}) was the most sensible parameter on the pump efficiency. And the pump efficiency had a maximum at {beta}=20.deg, {alpha}=110.deg and {iota}=240mm.

  7. Axial displacements in external and internal implant-abutment connection.

    Science.gov (United States)

    Lee, Ji-Hye; Kim, Dae-Gon; Park, Chan-Jin; Cho, Lee-Ra

    2014-02-01

    The purpose of this study was to evaluate the axial displacement of the abutments during clinical procedures by the tightening torque and cyclic loading. Two different implant-abutment connection systems were used (external butt joint connection [EXT]; internal tapered conical connection [INT]). The master casts with two implant replicas, angulated 10° from each other, were fabricated for each implant connection system. Four types of impression copings were assembled and tightened with the corresponding implants (hex transfer impression coping, non-hex transfer impression coping, hex pick-up impression coping, non-hex pick-up impression coping). Resin splinted abutments and final prosthesis were assembled. The axial displacement was measured from the length of each assembly, which was evaluated repeatedly, after 30 Ncm torque tightening. After 250 N cyclic loading of final prosthesis for 1,000,000 cycles, additional axial displacement was recorded. The mean axial displacement was statistically analyzed (repeated measured ANOVA). There was more axial displacement in the INT group than that of the EXT group in impression copings, resin splinted abutments, and final prosthesis. Less axial displacement was found at 1-piece non-hex transfer type impression coping than other type of impression copings in the INT group. There was more axial displacement at the final prosthesis than resin splinted abutments in the INT and the EXT groups. After 250 N cyclic loading of final prosthesis, the INT group showed more axial displacement than that of the EXT group. Internal tapered conical connection demonstrated a varying amount of axial displacement with tightening torque and cyclic loading. © 2012 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  8. Fast globally optimal segmentation of 3D prostate MRI with axial symmetry prior.

    Science.gov (United States)

    Qiu, Wu; Yuan, Jing; Ukwatta, Eranga; Sun, Yue; Rajchl, Martin; Fenster, Aaron

    2013-01-01

    We propose a novel global optimization approach to segmenting a given 3D prostate T2w magnetic resonance (MR) image, which enforces the inherent axial symmetry of the prostate shape and simultaneously performs a sequence of 2D axial slice-wise segmentations with a global 3D coherence prior. We show that the proposed challenging combinatorial optimization problem can be solved globally and exactly by means of convex relaxation. With this regard, we introduce a novel coupled continuous max-flow model, which is dual to the studied convex relaxed optimization formulation and leads to an efficient multiplier augmented algorithm based on the modern convex optimization theory. Moreover, the new continuous max-flow based algorithm was implemented on GPUs to achieve a substantial improvement in computation. Experimental results using public and in-house datasets demonstrate great advantages of the proposed method in terms of both accuracy and efficiency.

  9. [Preoperative assessment of renal vascular anatomy for donor nephrectomy: Is CT superior to MRI?].

    Science.gov (United States)

    Arvin-Berod, A; Bricault, I; Terrier, N; Skowron, O; Cadi, P; Boillot, B; Thuillier, C; Cluze, C; Descotes, J-L; Rambeaud, J-J; Long, J-A

    2011-01-01

    computed tomography angiography (CTA) and magnetic resonance angiography (MRA) are both used in the preoperative assessment of vascular anatomy before donor nephrectomy. Our objective was to determine retrospectively and to compare the sensitivity of CTA and MRA imaging in preoperative renal vascularisation in living kidney donors. between 1999 and 2007, 42 kidney donors were assessed in our center: 27 by MRA, 10 by CTA, and five by both techniques. Images were interpreted using multiplanar reconstructions. Results were compared retrospectively with peroperative findings; discordant cases were re-examined by an experienced radiologist. Numbers of vessels detected with imaging methods was compared with numbers actually found at the operating time. MRA showed 35/43 arteries (Se 81.4 %) and 33/34 veins (Se 97.1 %), and CTA showed 18/18 arteries (Se 100 %) and 15/16 veins (Se 93.8 %). The presence of multiple arteries was detected in only one third of cases (3/9) on MRI scans; this difference was statistically significant. The missed arteries were not detected on second examination of the MRI scans with the knowledge of peroperative findings. MRA is less sensitive than CTA for preoperative vascularisation imaging in living renal donors, especially in the detection of multiple renal arteries. 2010 Elsevier Masson SAS. All rights reserved.

  10. The preoperative cardiology consultation: Indications and risk modification

    NARCIS (Netherlands)

    M.W. de Groot (Mark); A. Spronk (Angela); S.E. Hoeks (Sanne); R.J. Stolker (Robert); F. van Lier (Felix)

    2017-01-01

    textabstractBackground The cardiologist is regularly consulted preop-eratively by anaesthesiologists. However, insights into the efficiency and usefulness of these consultations are unclear. Methods This is a retrospective study of 24,174 preoperatively screened patients ≥18 years scheduled for

  11. High Precision Axial Coordinate Readout for an Axial 3-D PET Detector Module using a Wave Length Shifter Strip Matrix

    CERN Document Server

    Braem, André; Joram, C; Séguinot, Jacques; Weilhammer, P; De Leo, R; Nappi, E; Lustermann, W; Schinzel, D; Johnson, I; Renker, D; Albrecht, S

    2007-01-01

    We describe a novel method to extract the axial coordinate from a matrix of long axially oriented crystals, which is based on wavelength shifting plastic strips. The method allows building compact 3-D axial gamma detector modules for PET scanners with excellent 3-dimensional spatial, timing and energy resolution while keeping the number of readout channels reasonably low. A voxel resolution of about 10 mm3 is expected. We assess the performance of the method in two independent ways, using classical PMTs and G-APDs to read out the LYSO (LSO) scintillation crystals and the wavelength shifting strips. We observe yields in excess of 35 photoelectrons from the strips for a 511 keV gamma and reconstruct the axial coordinate with a precision of about 2.5 mm (FWHM).

  12. Dual-detection confocal fluorescence microscopy: fluorescence axial imaging without axial scanning.

    Science.gov (United States)

    Lee, Dong-Ryoung; Kim, Young-Duk; Gweon, Dae-Gab; Yoo, Hongki

    2013-07-29

    We propose a new method for high-speed, three-dimensional (3-D) fluorescence imaging, which we refer to as dual-detection confocal fluorescence microscopy (DDCFM). In contrast to conventional beam-scanning confocal fluorescence microscopy, where the focal spot must be scanned either optically or mechanically over a sample volume to reconstruct a 3-D image, DDCFM can obtain the depth of a fluorescent emitter without depth scanning. DDCFM comprises two photodetectors, each with a pinhole of different size, in the confocal detection system. Axial information on fluorescent emitters can be measured by the axial response curve through the ratio of intensity signals. DDCFM can rapidly acquire a 3-D fluorescent image from a single two-dimensional scan with less phototoxicity and photobleaching than confocal fluorescence microscopy because no mechanical depth scans are needed. We demonstrated the feasibility of the proposed method by phantom studies.

  13. Health and imaging outcomes in axial spondyloarthritis

    NARCIS (Netherlands)

    Machado, P.M.

    2016-01-01

    This thesis focuses on the assessment and monitoring of health and imaging outcomes in axial spondyloarthritis (SpA) and the relationship between these outcomes. Four major contributions to the understanding and management of axial SpA were made: 1) the improvement and facilitation of the assessment

  14. Evaluation of interatomic potentials for rainbow scattering under axial channeling at KCl(0 0 1) surface by three-dimensional computer simulations based on binary collision approximation

    Energy Technology Data Exchange (ETDEWEB)

    Takeuchi, Wataru, E-mail: take@sp.ous.ac.jp

    2017-05-01

    The rainbow angles corresponding to prominent peaks in the angular distributions of scattered projectiles with small angle, attributed to rainbow scattering (RS), under axial surface channeling conditions are strongly influenced by the interatomic potentials between projectiles and target atoms. The dependence of rainbow angles on normal energy of projectile energy to the target surface, being experimentally obtained by Specht et al. for RS of He, N, Ne and Ar atoms under 〈1 0 0〉 and 〈1 1 0〉 axial channeling conditions at a KCl(0 0 1) surface with projectile energies of 1–60 keV, was evaluated by the three-dimensional computer simulations using the ACOCT code based on the binary collision approximation with interatomic pair potentials. Good agreement between the ACOCT results using the ZBL pair potential and the individual pair potentials calculated from Hartree-Fock (HF) wave functions and the experimental ones was found for RS of He, N and Ne atoms from the atomic rows along 〈1 0 0〉 direction. For 〈1 1 0〉 direction, the ACOCT results employing the Moliere pair potential with adjustable screening length of O’Connor-Biersack (OB) formula, the ZBL pair potential and the individual HF pair potentials except for Ar → KCl using the OB pair potential are nearly in agreement with the experimental ones.

  15. Preoperative Computed Tomography-Guided Percutaneous Hookwire Localization of Metallic Marker Clips in the Breast with a Radial Approach: Initial Experience

    Energy Technology Data Exchange (ETDEWEB)

    Uematsu, T.; Kasami, M.; Uchida, Y.; Sanuki, J.; Kimura, K.; Tanaka, K.; Takahashi, K. [Dept. of Diagnostic Radiology, Dept. of Pathology, and Dept. of Breast Surgery, Shizuoka Cancer Center Hospital, Naga-izumi, Shizuoka (Japan)

    2007-07-15

    Background: Hookwire localization is the current standard technique for radiological marking of nonpalpable breast lesions. Stereotactic directional vacuum-assisted breast biopsy (SVAB) is of sufficient sensitivity and specificity to replace surgical biopsy. Wire localization for metallic marker clips placed after SVAB is needed. Purpose: To describe a method for performing computed tomography (CT)-guided hookwire localization using a radial approach for metallic marker clips placed percutaneously after SVAB. Material and Methods: Nineteen women scheduled for SVAB with marker-clip placement, CT-guided wire localization of marker clips, and, eventually, surgical excision were prospectively entered into the study. CT-guided wire localization was performed with a radial approach, followed by placement of a localizing marker-clip surgical excision. Feasibility and reliability of the procedure and the incidence of complications were examined. Results: CT-guided wire localization surgical excision was successfully performed in all 19 women without any complications. The mean total procedure time was 15 min. The median distance on CT image from marker clip to hookwire was 2 mm (range 0-3 mm). Conclusion: CT-guided preoperative hookwire localization with a radial approach for marker clips after SVAB is technically feasible.

  16. Preoperative computed tomography-guided percutaneous hookwire localization of metallic marker clips in the breast with a radial approach: initial experience.

    Science.gov (United States)

    Uematsu, T; Kasami, M; Uchida, Y; Sanuki, J; Kimura, K; Tanaka, K; Takahashi, K

    2007-06-01

    Hookwire localization is the current standard technique for radiological marking of nonpalpable breast lesions. Stereotactic directional vacuum-assisted breast biopsy (SVAB) is of sufficient sensitivity and specificity to replace surgical biopsy. Wire localization for metallic marker clips placed after SVAB is needed. To describe a method for performing computed tomography (CT)-guided hookwire localization using a radial approach for metallic marker clips placed percutaneously after SVAB. Nineteen women scheduled for SVAB with marker-clip placement, CT-guided wire localization of marker clips, and, eventually, surgical excision were prospectively entered into the study. CT-guided wire localization was performed with a radial approach, followed by placement of a localizing marker-clip surgical excision. Feasibility and reliability of the procedure and the incidence of complications were examined. CT-guided wire localization surgical excision was successfully performed in all 19 women without any complications. The mean total procedure time was 15 min. The median distance on CT image from marker clip to hookwire was 2 mm (range 0-3 mm). CT-guided preoperative hookwire localization with a radial approach for marker clips after SVAB is technically feasible.

  17. Preoperation of Hamaoka Nuclear Power Station Unit No. 4

    International Nuclear Information System (INIS)

    Fukuyo, Tadashi; Kurata, Satoshi

    1994-01-01

    Chubu Electric Power Co. finished preoperation of Hamaoka Nuclear Power Station Unit No. 4 in September, 1993. Although unit 4 has the same reactor design as unit 3, its rated electrical output (1,137MW) is 37MW more than that of unit 3. This increase was achieved mainly by adopting a Moisture Separater Heater in the turbine system. We started preoperation of unit 4 in November 1992 and performed various tests at electrical outputs of 20%, 50%, 75%, and 100%. We finished preoperation without any scram or other major problems and obtained satisfactory results for the functions and performance of the plant. This paper describes the major results of unit 4 preoperation. (author)

  18. Reducing preoperative fasting time: A trend based on evidence.

    Science.gov (United States)

    de Aguilar-Nascimento, José Eduardo; Dock-Nascimento, Diana Borges

    2010-03-27

    Preoperative fasting is mandatory before anesthesia to reduce the risk of aspiration. However, the prescribed 6-8 h of fasting is usually prolonged to 12-16 h for various reasons. Prolonged fasting triggers a metabolic response that precipitates gluconeogenesis and increases the organic response to trauma. Various randomized trials and meta-analyses have consistently shown that is safe to reduce the preoperative fasting time with a carbohydrate-rich drink up to 2 h before surgery. Benefits related to this shorter preoperative fasting include the reduction of postoperative gastrointestinal discomfort and insulin resistance. New formulas containing amino acids such as glutamine and other peptides are being studied and are promising candidates to be used to reduce preoperative fasting time.

  19. The Preoperative Composite Physiologic Index May Predict Mortality in Lung Cancer Patients with Combined Pulmonary Fibrosis and Emphysema.

    Science.gov (United States)

    Ueno, Fumika; Kitaguchi, Yoshiaki; Shiina, Takayuki; Asaka, Shiho; Miura, Kentaro; Yasuo, Masanori; Wada, Yosuke; Yoshizawa, Akihiko; Hanaoka, Masayuki

    2017-01-01

    It remains unclear whether the preoperative pulmonary function parameters and prognostic indices that are indicative of nutritional and immunological status are associated with prognosis in lung cancer patients with combined pulmonary fibrosis and emphysema (CPFE) who have undergone surgery. The aim of this study is to identify prognostic determinants in these patients. The medical records of all patients with lung cancer associated with CPFE who had undergone surgery at Shinshu University Hospital were retrospectively reviewed to obtain clinical data, including the results of preoperative pulmonary function tests and laboratory examinations, chest high-resolution computed tomography (HRCT), and survival. Univariate Cox proportional hazards regression analysis showed that a high pathological stage of the lung cancer, a higher preoperative serum carcinoembryonic antigen level, and a higher preoperative composite physiologic index (CPI) were associated with a high risk of death. Multivariate analysis showed that a high pathological stage of the lung cancer (HR: 1.579; p = 0.0305) and a higher preoperative CPI (HR: 1.034; p = 0.0174) were independently associated with a high risk of death. In contrast, the severity of fibrosis or emphysema on chest HRCT, the individual pulmonary function parameters, the prognostic nutritional index, the neutrophil-to-lymphocyte ratio, and the platelet-to-lymphocyte ratio were not associated with prognosis. In the Kaplan-Meier analysis, the log-rank test showed significant differences in survival between the high-CPI and the low-CPI group (p = 0.0234). The preoperative CPI may predict mortality and provide more powerful prognostic information than individual pulmonary function parameters in lung cancer patients with CPFE who have undergone surgery. © 2017 S. Karger AG, Basel.

  20. sizing of wind powered axial flux permanent magnet alternator using

    African Journals Online (AJOL)

    user

    2016-10-04

    Oct 4, 2016 ... Keywords: Wind-Power, Axial flux, Axial Flux Permanent Machines (AFPM), Axial Flux Permanent Magnet ... energy for power generation, a high constraint is the .... arrangements as Single-Rotor Single-Stator Structure.

  1. Computerized axial tomography and diagnosis of multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Paulo R.M. Bittencourt

    1983-06-01

    Full Text Available Computed axial tomography (C.T. findings are illustrated in 3 patients who presented with C.T. changes suggesting respectively chronic M.S., acute M.S., and an appearance simulating a malignant tumour. Review of the literature shows that the chronic form with cerebral atrophy and low density lesions in the hemispheres is common in patients with a long history and is unlikely to cause diagnostic difficulty. The acute presentation is less common and could be confused with a variety of causes of multiple low density enhancing lesions. The C.T. diagnosis of M.S. is more difficult in rare cases in which plaques cause mass effect and show ring enhancement; all 3 such cases in the literature were subjected to cerebral biopsy.

  2. Buoyant Helical Twin-Axial Wire Antenna

    Science.gov (United States)

    2016-11-15

    February 2017 The below identified patent application is available for licensing. Requests for information should be addressed to...300169 1 of 9 BUOYANT HELICAL TWIN-AXIAL WIRE ANTENNA CROSS REFERENCE TO OTHER PATENT APPLICATIONS [0001] This application is a divisional...application and claims the benefit of the filing date of United States Patent Application No. 14/280,889; filed on May 19, 2014; and entitled “Twin-Axial

  3. Axial forces in centrifugal compressor couplings

    Science.gov (United States)

    Ivanov, A. N.; Ivanov, N. M.; Yun, V. K.

    2017-08-01

    The article presents the results of the theoretical and experimental investigation of axial forces arising in the toothed and plate couplings of centrifugal compressor shaft lines. Additional loads on the thrust bearing are considered that can develop in the toothed couplings as a result of coupled rotors misalignment. Design relationships to evaluate the level of axial forces and recommendations for their reduction in the operating conditions are given.

  4. Chiral filter, axial charges and Gamow-Teller strengths

    International Nuclear Information System (INIS)

    Rho, M.

    1983-09-01

    The different ways that nuclear matter responds to the weak axial-vector current are interpreted in terms of modification of the ''vacuum'' in baryon-rich environments. The notion of ''chiral filter'' is introduced. Use of a ward identity is suggested. The Gamow-Teller quenching and the enhanced axial charge in O + O - transitions follow from this. I also discuss briefly possible relevance of the nucleon as a topological soliton configuration to the global property of nuclear axial response functions

  5. Fuel rod with axial regions of annular and standard fuel pellets

    International Nuclear Information System (INIS)

    Freeman, T.R.

    1991-01-01

    This patent describes a fuel rod for use in a nuclear reactor fuel assembly. It comprises: an elongated hollow cladding tube; a pair of end plugs connected to and sealing the cladding tube at opposite ends of thereof; and an axial stack of fuel pellets contained in and extending between the end plugs at the opposite ends of the tube, all of the fuel pellets contained in the tube being composed of fissile material being enriched above the level of natural enrichment; the fuel pellets in the stack thereof being provided in an arrangement of axial regions. The arrangement of axial regions including a pair of first axial regions defined respectively at the opposite ends of the pellet stack adjacent to the respective end plugs. The pellets in the first axial regions being identical in number and having annular configurations with an annulus of a first void size. The arrangement of axial regions also including another axial region defined between the first axial regions, some of the pellets in the another axial region having solid configurations

  6. Atlanto-axial malformation and instability in dogs with pituitary dwarfism due to an LHX3 mutation.

    Science.gov (United States)

    Voorbij, A M W Y; Meij, B P; van Bruggen, L W L; Grinwis, G C M; Stassen, Q E M; Kooistra, H S

    2015-01-01

    Canine pituitary dwarfism or combined pituitary hormone deficiency (CPHD) in shepherd dogs is associated with an LHX3 mutation and can lead to a wide range of clinical manifestations. Some dogs with CPHD have neurological signs that are localized to the cervical spine. In human CPHD, caused by an LHX3 mutation, anatomical abnormalities in the atlanto-axial (C1-C2) joint have been described. To evaluate the presence of atlanto-axial malformations in dogs with pituitary dwarfism associated with an LHX3 mutation and to investigate the degree of similarity between the atlanto-axial anomalies found in canine and human CPHD patients with an LHX3 mutation. Three client-owned Czechoslovakian wolfdogs and 1 client-owned German shepherd dog, previously diagnosed with pituitary dwarfism caused by an LHX3 mutation, with neurological signs indicating a cervical spinal disorder. Radiography, computed tomography, and magnetic resonance imaging of the cranial neck and skull, necropsy, and histology. Diagnostic imaging identified abnormal positioning of the dens axis and incomplete ossification of the suture lines between the ossification centers of the atlas with concurrent atlanto-axial instability and dynamic compression of the spinal cord by the dens axis. The malformations and aberrant motion at C1-C2 were confirmed at necropsy and histology. The atlanto-axial abnormalities of the dwarf dogs resemble those encountered in human CPHD patients with an LHX3 mutation. These findings suggest an association between the LHX3 mutation in dogs with CPHD and atlanto-axial malformations. Consequently, pituitary dwarfs should be monitored closely for neurological signs. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of American College of Veterinary Internal Medicine.

  7. Chiral lattice fermions, minimal doubling, and the axial anomaly

    International Nuclear Information System (INIS)

    Tiburzi, B. C.

    2010-01-01

    Exact chiral symmetry at finite lattice spacing would preclude the axial anomaly. In order to describe a continuum quantum field theory of Dirac fermions, lattice actions with purported exact chiral symmetry must break the flavor-singlet axial symmetry. We demonstrate that this is indeed the case by using a minimally doubled fermion action. For simplicity, we consider the Abelian axial anomaly in two dimensions. At finite lattice spacing and with gauge interactions, the axial anomaly arises from nonconservation of the flavor-singlet current. Similar nonconservation also leads to the axial anomaly in the case of the naieve lattice action. For minimally doubled actions, however, fine-tuning of the action and axial current is necessary to arrive at the anomaly. Conservation of the flavor nonsinglet vector current additionally requires the current to be fine-tuned. Finally, we determine that the chiral projection of a minimally doubled fermion action can be used to arrive at a lattice theory with an undoubled Dirac fermion possessing the correct anomaly in the continuum limit.

  8. Catawba nuclear station preoperational ALARA review

    International Nuclear Information System (INIS)

    Deal, W.P.

    1985-01-01

    This paper describes the particular emphasis placed on preoperational as los as reasonably achievable (ALARA) considerations at Duke Power's Catawba Nuclear Station. A strong station commitment to the ALARA philosophy, and review of existing capabilities, led to development of an aggressive two-part ALARA program. Capabilities consisted of sufficient numbers of available personnel, lengthy lead time during construction, a very detailed plastic model, and a sister plant of similar design. The program, as developed, consisted of a preoperational program, which looked at design and construction aspects of ALARA, and the operational program, dealing with the ALARA committee and operational problems. MAnagement's philosophy of holding everyone responsible for ALARA provided the motivation to organize the preoperational program to use that resource. The Health Physics group accepted responsibility for development, coordination, and reviewer training. The problem provided a base to build on as station personnel gained experience in their own crafts and radiation protection in general

  9. Preoperative and postoperative serial assessments of postural balance and fall risk in patients with arthroscopic anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Gokalp, Oguzhan; Akkaya, Semih; Akkaya, Nuray; Buker, Nihal; Gungor, Harun R; Ok, Nusret; Yorukoglu, Cagdas

    2016-04-27

    Impaired postural balance due to somatosensory data loss with mechanical instability has been shown in patients with ACL deficiency. To assess postural balance in patients with ACL insufficiency prior to surgery and following reconstruction with serial evaluations. Thirty patients (mean age of 27.7 ± 6.7 years) who underwent arthroscopic reconstruction of ACL with bone-patellar tendon-bone autograft were examined for clinical and functional variables at preoperative day and postoperative 12th week. Posturographic analysis were performed by using Tetrax Interactive Balance System (Sunlight Medical Ltd, Israel) at preoperative day, at 4th, 8th, and 12th weeks following reconstruction. Data computed by posturographic software by the considerations of the oscillation velocities of body sways is fall risk as a numeric value (0-100, lower values indicate better condition). All of the patients (mean age of 27.7 ± 6.7 years) had significant improvements for clinical, functional evaluations and fall risk (pfall risk was within high-risk category (59.9 ± 22.8) preoperatively. The highest fall risk was detected at postoperative 4th week. Patients had high fall risk at 8th week similar to preoperative value. Mean fall risk decreased to low level risk at 12th week. Preoperative symptom duration had relationships with preoperative fall risk and postoperative improvement of fall risk (p= 0.001, r= -0.632, p= 0.001, r= -0.870, respectively). The improvement of fall risk was higher in patients with symptoms shorter than 6 months (p= 0.001). According to these results, mean fall risk of patients with ACL insufficiency was within high risk category preoperatively, and fall risk improves after surgical reconstruction, but as the duration of complaints lengthens especially longer than 6 months, the improvement of fall risk decreases following reconstruction.

  10. The appropriateness of preoperative blood testing: A retrospective ...

    African Journals Online (AJOL)

    Background. Inappropriate preoperative blood testing can negatively contribute to healthcare costs. Objective. To determine the extent and cost implications of inappropriate preoperative blood testing in adult patients booked for orthopaedic, general or trauma surgical procedures at a regional hospital in KwaZulu-Natal ...

  11. Axial Myopia and its Influence on Diabetic Retinopathy

    International Nuclear Information System (INIS)

    Tayyab, H.; Haider, M. A.; Bukhari, S. A. H.

    2014-01-01

    Objective: To evaluate the correlation between axial myopia and diabetic retinopathy. Study Design: Cross-sectional study. Place and Duration of Study: Eye Department of Postgraduate Medical Institute, Lahore General Hospital, from August 2012 to February 2013. Methodology: A total of 258 participants suffering from type-2 diabetic retinopathy were included. Axial length was measured by two optometrists using contact type ultrasound biometer. Colored retinal photographs, red free retinal photographs and Fundus Fluorescein Angiography (FFA) were performed on all patients using standard fundus camera. All fundus photographs and angiograms were independently reviewed and graded by two qualified vitreoretinal fellows. Results: Out of 258 patients, 163 were males (63.2%) and 95 (36.8%) were females. Average age of patients was 56.30 +- 7.57 years. Average axial length of right and left eyes were 23.16 mm and 23.15 mm respectively. There was statistically significant negative correlation between axial length and severity of diabetic retinopathy in the right eye, (Spearman correlation = -0.511, p = 0.0001) as well as the left eye (Spearman correlation = -0.522, p = 0.0001). Conclusion: There is a protective influence of longer axial length of globe on the stage and severity of diabetic retinopathy. This study may help in modifying the screening protocol for diabetic retinopathy amongst patients of differing axial lengths. (author)

  12. Prediction of velocity distributions in rod bundle axial flow, with a statistical model (K-epsilon) of turbulence

    International Nuclear Information System (INIS)

    Silva Junior, H.C. da.

    1978-12-01

    Reactor fuel elements generally consist of rod bundles with the coolant flowing axially through the region between the rods. The confiability of the thermohydraulic design of such elements is related to a detailed description of the velocity field. A two-equation statistical model (K-epsilon) of turbulence is applied to compute main and secondary flow fields, wall shear stress distributions and friction factors of steady, fully developed turbulent flows, with incompressible, temperature independent fluid flowing axially through triangular or square arrays of rod bundles. The numerical procedure uses the vorticity and the stream function to describe the velocity field. Comparison with experimental and analytical data of several investigators is presented. Results are in good agreement. (Author) [pt

  13. Transitions in axial morphology along the Southeast Indian Ridge

    Science.gov (United States)

    Ma, Ying; Cochran, James R.

    1996-07-01

    Shipboard bathymetric and magnetic profiles across the Southeast Indian Ridge (SEIR) were analyzed in order to examine the nature of along-axis variations in axial morphology at this intermediate spreading rate ridge. Three types of axial morphology are observed along the SEIR: an axial high, a shallow (200-700 m deep) axial valley and a deep (>1000 m deep) axial valley. An axial high is found to the east of the Australian-Antarctic Discordance (AAD) (east of 128°E) and between 82°E and 104°E. A shallow rift valley is found from 104°E to 114°E and from 82°E westward past the Amerstdam/St. Paul hotspot (ASP) to about 30°S, 75°E. Deep rift valleys are found from 114°E to 128°E in the vicinity of the AAD and from the Indian Ocean Triple Junction (IOTJ) at 25°S, 70°E to about 30°S, 75°E. The transition near 30°S occurs in an area of constant zero-age depth and does not appear to result from an increase in mantle temperature. It could be the result of the rapid increase in spreading rate along that portion of the SEIR. The most likely cause of the other transitions in axial morphology is variations in mantle temperature. The transitions between the different types of axial morphology are well defined and occur over a limited distance. Transitions in axial morphology are accompanied by significant changes in ridge flank topographic roughness. The transitions from axial valleys to axial highs are also accompanied by changes in the amplitude of the seafloor magnetic anomalies. Our observations suggest that there are distinct modes rather than a continuum of axial morphology on the SEIR and that there appears to be a "threshold" mechanism for a rapid change between different states of axial morphology. The ASP has only a limited influence on the SEIR. The ridge axis is marked by an axial valley for the entire distance from the IOTJ up to and past the ASP. The ridge axis becomes shallower as the ASP is approached from the northwest but only by about 300 m over

  14. Preoperative blood transfusions for sickle cell disease

    Science.gov (United States)

    Estcourt, Lise J; Fortin, Patricia M; Trivella, Marialena; Hopewell, Sally

    2016-01-01

    Background Sickle cell disease is one of the commonest severe monogenic disorders in the world, due to the inheritance of two abnormal haemoglobin (beta globin) genes. Sickle cell disease can cause severe pain, significant end-organ damage, pulmonary complications, and premature death. Surgical interventions are more common in people with sickle cell disease, and occur at much younger ages than in the general population. Blood transfusions are frequently used prior to surgery and several regimens are used but there is no consensus over the best method or the necessity of transfusion in specific surgical cases. This is an update of a Cochrane review first published in 2001. Objectives To determine whether there is evidence that preoperative blood transfusion in people with sickle cell disease undergoing elective or emergency surgery reduces mortality and perioperative or sickle cell-related serious adverse events. To compare the effectiveness of different transfusion regimens (aggressive or conservative) if preoperative transfusions are indicated in people with sickle cell disease. Search methods We searched for relevant trials in The Cochrane Library, MEDLINE (from 1946), Embase (from 1974), the Transfusion Evidence Library (from 1980), and ongoing trial databases; all searches current to 23 March 2016. We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group Trials Register: 18 January 2016. Selection criteria All randomised controlled trials and quasi-randomised controlled trials comparing preoperative blood transfusion regimens to different regimens or no transfusion in people with sickle cell disease undergoing elective or emergency surgery. There was no restriction by outcomes examined, language or publication status. Data collection and analysis Two authors independently assessed trial eligibility and the risk of bias and extracted data. Main results Three trials with 990 participants were eligible for inclusion in the review. There were no

  15. Multidetector computed tomography for preoperative assessment of hepatic vasculature and prediction of splenic artery steal syndrome in patients with liver cirrhosis before transplantation

    International Nuclear Information System (INIS)

    Grieser, Christian; Denecke, Timm; Steffen, Ingo G.; Avgenaki, Maria; Froehling, Vera; Schnapauff, Dirk; Lehmkuhl, Lukas; Stelter, Lars; Streitparth, Florian; Rothe, Jan-Holger; Hamm, Bernd; Haenninen, Enrique Lopez; Mogl, Martina; Langrehr, Jan

    2010-01-01

    The purpose of this study was to evaluate the accuracy of MDCT for preoperative assessment of hepatic vascular anatomy and the identification of liver-transplantation (OLT) patients at risk of developing subsequent splenic artery steal syndrome (SASS). A total of 145 patients with liver cirrhosis who had undergone OLT and had pre-operative three-phase MDCT (4- to 64-rows) within 100 days before OLT were enrolled retrospectively. MDCT and 3Ds were reviewed by two independent blinded observers (O1/O2). Pre-operative imaging findings were correlated with intra-operative results; findings indicative for SASS were correlated with clinical data and DSA. Among all 145 patients, 16 patients (11%) showed accessory hepatic arteries (accuracy O1/O2, 97%; with 3Ds, 100%); 32 (22%) patients had replaced hepatic arteries (accuracy O1, 97%; O2, 95%; with 3Ds, 100%; κ=0.87 and 0.89, P<0.001). Among 119 patients, 12 patients developed SASS after OLT. The logistic regression model revealed the spleen volume (P=0.0105) as a predictive factor of SASS. With spleen volumes ≥829 ml, an accuracy of 75% for prediction of SASS was obtained. MDCT with three-dimensional post-processing (3Ds) was highly accurate for pre-operative hepatic vessel evaluation in patients before OLT. In addition, spleen volume was a predictive factor for developing SASS after OLT. (orig.)

  16. Multidetector-row computed tomography in the preoperative diagnosis of intestinal complications caused by clinically unsuspected ingested dietary foreign bodies: a case series emphasizing the use of volume rendering techniques

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Augusto Cesar Vieira; Torres, Ulysses dos Santos; Oliveira, Eduardo Portela de; Gual, Fabiana; Bauab Junior, Tufik, E-mail: usantor@yahoo.com.br [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Hospital de Base. Serv. de Radiologia e Diagnostico por Imagem; Westin, Carlos Eduardo Garcia [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Hospital de Base. Cirurgia Geral; Cardoso, Luciana Vargas [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Hospital de Base. Setor de Tomografia Computadorizada

    2013-11-15

    Objective: the present study was aimed at describing a case series where a preoperative diagnosis of intestinal complications secondary to accidentally ingested dietary foreign bodies was made by multidetector-row computed tomography (MDCT), with emphasis on complementary findings yielded by volume rendering techniques (VRT) and curved multiplanar reconstructions (MPR). Materials and Methods: The authors retrospectively assessed five patients with surgically confirmed intestinal complications (perforation and/or obstruction) secondary to unsuspected ingested dietary foreign bodies, consecutively assisted in their institution between 2010 and 2012. Demographic, clinical, laboratory and radiological data were analyzed. VRT and curved MPR were subsequently performed. Results: preoperative diagnosis of intestinal complications was originally performed in all cases. In one case the presence of a foreign body was not initially identified as the causal factor, and the use of complementary techniques facilitated its retrospective identification. In all cases these tools allowed a better depiction of the entire foreign bodies on a single image section, contributing to the assessment of their morphology. Conclusion: although the use of complementary techniques has not had a direct impact on diagnostic performance in most cases of this series, they may provide a better depiction of foreign bodies' morphology on a single image section. (author)

  17. The Axially Symmetric One-Monopole

    International Nuclear Information System (INIS)

    Wong, K.-M.; Teh, Rosy

    2009-01-01

    We present new classical generalized one-monopole solution of the SU(2) Yang-Mills-Higgs theory with the Higgs field in the adjoint representation. We show that this solution with θ-winding number m = 1 and φ-winding number n = 1 is an axially symmetric generalization of the 't Hooft-Polyakov one-monopole. We construct this axially symmetric one-monopole solution by generalizing the large distance asymptotic solutions of the 't Hooft-Polyakov one-monopole to the Jacobi elliptic functions and solving the second order equations of motion numerically when the Higgs potential is vanishing. This solution is a non-BPS solution.

  18. «FLARES» IN AXIAL SPONDYLOARTHRITIS

    Directory of Open Access Journals (Sweden)

    Sh. F. Erdes

    2016-01-01

    Full Text Available The clear definition of the concept of «flare in axial spondyloarthritis» is of paramount importance for clinical trials and routine practice in particular. It will be able to unify the characteristics of outcomes over a particular period of time on the one hand and to standardize therapeutic approaches on the other. On 4 February 2016, the journal Annals of Rheumatic Diseases published the on-line paper «Preliminary definitions of 'flare' in axial spondyloarthritis, based on pain, BASDAI and ASDAS-CRP: an ASAS initiative» by L. Gossec et al., which was devoted to this topic.

  19. Optimal ancilla-free Pauli+V circuits for axial rotations

    Energy Technology Data Exchange (ETDEWEB)

    Blass, Andreas [Mathematics, University of Michigan, Ann Arbor, Michigan 48109-1043 (United States); Bocharov, Alex; Gurevich, Yuri [Microsoft Research, Redmond, Washington 98052 (United States)

    2015-12-15

    We address the problem of optimal representation of single-qubit rotations in a certain unitary basis consisting of the so-called V gates and Pauli matrices. The V matrices were proposed by Lubotsky, Philips, and Sarnak [Commun. Pure Appl. Math. 40, 401–420 (1987)] as a purely geometric construct in 1987 and recently found applications in quantum computation. They allow for exceptionally simple quantum circuit synthesis algorithms based on quaternionic factorization. We adapt the deterministic-search technique initially proposed by Ross and Selinger to synthesize approximating Pauli+V circuits of optimal depth for single-qubit axial rotations. Our synthesis procedure based on simple SL{sub 2}(ℤ) geometry is almost elementary.

  20. Preoperative screening: value of previous tests.

    Science.gov (United States)

    Macpherson, D S; Snow, R; Lofgren, R P

    1990-12-15

    To determine the frequency of tests done in the year before elective surgery that might substitute for preoperative screening tests and to determine the frequency of test results that change from a normal value to a value likely to alter perioperative management. Retrospective cohort analysis of computerized laboratory data (complete blood count, sodium, potassium, and creatinine levels, prothrombin time, and partial thromboplastin time). Urban tertiary care Veterans Affairs Hospital. Consecutive sample of 1109 patients who had elective surgery in 1988. At admission, 7549 preoperative tests were done, 47% of which duplicated tests performed in the previous year. Of 3096 previous results that were normal as defined by hospital reference range and done closest to the time of but before admission (median interval, 2 months), 13 (0.4%; 95% CI, 0.2% to 0.7%), repeat values were outside a range considered acceptable for surgery. Most of the abnormalities were predictable from the patient's history, and most were not noted in the medical record. Of 461 previous tests that were abnormal, 78 (17%; CI, 13% to 20%) repeat values at admission were outside a range considered acceptable for surgery (P less than 0.001, frequency of clinically important abnormalities of patients with normal previous results with those with abnormal previous results). Physicians evaluating patients preoperatively could safely substitute the previous test results analyzed in this study for preoperative screening tests if the previous tests are normal and no obvious indication for retesting is present.

  1. Obstetric spinal hypotension: Preoperative risk factors and the ...

    African Journals Online (AJOL)

    Obstetric spinal hypotension: Preoperative risk factors and the development of a preliminary risk score – the PRAM score. ... We used empirical cut-point estimations in a logistic regression model to develop a scoring system for prediction of hypotension. Results. From 504 eligible patients, preoperative heart rate (odds ratio ...

  2. Risk Factors for Elevated Preoperative Alkaline Phosphatase in Patients with Refractory Secondary Hyperparathyroidism.

    Science.gov (United States)

    Yang, Meng; Zhang, Ling; Huang, Linping; Sun, Xiaoliang; Ji, Haoyang; Lu, Yao

    2017-12-01

    Elevated preoperative levels of alkaline phosphatase (ALP) in patients with refractory secondary hyperparathyroidism are correlated with postoperative hypocalcemia and mortality. The aim of this study was to identify the predictors of preoperative ALP in patients with secondary hyperparathyroidism. From April 2012 to December 2015, 220 patients with refractory secondary hyperparathyroidism undergoing total parathyroidectomy without autotransplantation were reviewed. A total of 164 patients presented with elevated preoperative ALP. Univariate analysis showed that patients with elevated ALP were significantly younger. The elevated ALP group had significantly higher levels of preoperative parathyroid hormone (PTH), lower preoperative serum calcium, higher preoperative phosphorus, lower postoperative hypocalcemia, and a longer hospital stay. Logistic regression analysis showed that elevated preoperative PTH was a significant independent risk factor for elevated preoperative ALP (P = 0.000), and its value of 1624 pg/mL was the optimal cutoff point. Factors predictive of elevated preoperative ALP in patients with secondary hyperparathyroidism include preoperative PTH. Earlier surgery, aggressive calcium supplementation, and more careful or aggressive postoperative care for high-risk patients are needed.

  3. WE-AB-BRA-09: Registration of Preoperative MRI to Intraoperative Radiographs for Automatic Vertebral Target Localization

    Energy Technology Data Exchange (ETDEWEB)

    De Silva, T; Uneri, A; Ketcha, M; Reaungamornrat, S; Goerres, J [Johns Hopkins University, Baltimore, MD (United States); Vogt, S; Kleinszig, G [Siemens Healthcare, Erlangen (Germany); Wolinsky, J [The Johns Hopkins Hospital, Baltimore, MD (United States); Siewerdsen, JH

    2016-06-15

    Purpose: Accurate localization of target vertebrae is essential to safe, effective spine surgery, but wrong-level surgery occurs with surprisingly high frequency. Recent research yielded the “LevelCheck” method for 3D-2D registration of preoperative CT to intraoperative radiographs, providing decision support for level localization. We report a new method (MR-LevelCheck) to perform 3D-2D registration based on preoperative MRI, presenting a solution for the increasingly common scenario in which MRI (not CT) is used for preoperative planning. Methods: Direct extension of LevelCheck is confounded by large mismatch in image intensity between MRI and radiographs. The proposed method overcomes such challenges with a simple vertebrae segmentation. Using seed points at centroids, vertebrae are segmented using continuous max-flow method and dilated by 1.8 mm to include surrounding cortical bone (inconspicuous in T2w-MRI). MRI projections are computed (analogous to DRR) using segmentation and registered to intraoperative radiographs. The method was tested in a retrospective IRB-approved study involving 11 patients undergoing cervical, thoracic, or lumbar spine surgery following preoperative MRI. Registration accuracy was evaluated in terms of projection-distance-error (PDE) between the true and estimated location of vertebrae in each radiograph. Results: The method successfully registered each preoperative MRI to intraoperative radiographs and maintained desirable properties of robustness against image content mismatch, and large capture range. Segmentation achieved Dice coefficient = 89.2 ± 2.3 and mean-absolute-distance (MAD) = 1.5 ± 0.3 mm. Registration demonstrated robust performance under realistic patient variations, with PDE = 4.0 ± 1.9 mm (median ± iqr) and converged with run-time = 23.3 ± 1.7 s. Conclusion: The MR-LevelCheck algorithm provides an important extension to a previously validated decision support tool in spine surgery by extending its utility to

  4. Pre-operative fasting guidelines: an update

    DEFF Research Database (Denmark)

    Søreide, E; Eriksson, L I; Hirlekar, G

    2005-01-01

    Liberal pre-operative fasting routines have been implemented in most countries. In general, clear fluids are allowed up to 2 h before anaesthesia, and light meals up to 6 h. The same recommendations apply for children and pregnant women not in labour. In children......Liberal pre-operative fasting routines have been implemented in most countries. In general, clear fluids are allowed up to 2 h before anaesthesia, and light meals up to 6 h. The same recommendations apply for children and pregnant women not in labour. In children...

  5. Preoperative Quality of Life in Patients with Gastric Cancer

    OpenAIRE

    Suk, Hyoam; Kwon, Oh Kyung; Yu, Wansik

    2015-01-01

    Purpose We evaluated the socio-personal and clinical factors that can affect preoperative quality of life to determine how to improve preoperative quality of life in patients with gastric cancer. Materials and Methods The preoperative quality of life data of 200 patients (68 females and 132 males; mean age 58.9?12.6 years) with gastric cancer were analyzed according to socio-personal and clinical factors. The Korean versions of the European Organization for Research and Treatment of Cancer (E...

  6. Preoperative radiotherapy for bone and soft tissue sarcoma

    International Nuclear Information System (INIS)

    Matsumoto, Seiichi; Kawaguchi, Noriyoshi; Amino, Katsuhisa; Manabe, Jun; Yamashita, Takashi; Kaneta, Kouichi; Furuya, Kohtaro; Isobe, Yasushi.

    1989-01-01

    The role of preoperative radiotherapy was evaluated in 16 cases with soft tissue sarcoma and 13 cases with osteosarcoma. Nine osteosarcoma cases underwent radiotherapy of whole lesion, and 4 cases had radiotherapy only of the surgically uncurable portion. There were no local recurrences in M0 cases, but skin necrosis occurred in the whole radiation group. As for the soft tissue sarcomas, local recurrence was not seen in virgin cases, but two cases which had received previous treatment showed local recurrence. There were no cases with severe side effects. Partial radiotherapy was effective as preoperative treatment for osteosarcoma. Preoperative radiotherapy is better than postoperative radiotherapy from many standpoints. (author)

  7. Preoperative physical examination and imaging of femoroacetabular impingement prior to hip arthroscopy-a systematic review.

    Science.gov (United States)

    Haldane, Chloe E; Ekhtiari, Seper; de Sa, Darren; Simunovic, Nicole; Ayeni, Olufemi R

    2017-08-01

    The purpose of this systematic review is to report current preoperative assessment for femoroacetabular impingement (FAI) including physical examination and imaging modalities prior to hip arthroscopy, and report current imaging measures used in the diagnosis of FAI. The electronic databases MEDLINE, EMBASE and PubMed were searched and screened in duplicate for relevant studies. Data regarding patient demographics, non-operative treatment, preoperative assessment including physical examination and imaging prior to hip arthroscopy were abstracted. Study quality was assessed in duplicate using the Methodological Index for Non-Randomized Studies criteria. Sixty-eight studies of fair quality evidence that involved a total of 5125 patients (5400 hips) were included. In total, 56% of all patients were male and mean age was 36 years (SD ± 10.0). Within physical examination, FADIR impingement testing was reported in 57% of patients. All included studies reported plain radiographic imaging as a component of preoperative assessment with anterior-posterior pelvis view being the most commonly reported view, followed by the cross-table lateral and Dunn views. Magnetic resonance imaging was obtained for 52% of included patients and computed tomography for 26% of patients. The most commonly reported measure within imaging for the diagnosis of cam type impingement was alpha angle (66%), whereas for pincer type impingement, the cross-over sign (48%) was most reported. Preoperative assessment is underreported in the FAI literature. Improved reporting is warranted to develop a more consistent and validated diagnostic algorithm for FAI to enhance patient selection. Level of evidence : Level IV, Systematic Review of Level I-IV Studies.

  8. Preoperative physical examination and imaging of femoroacetabular impingement prior to hip arthroscopy—a systematic review

    Science.gov (United States)

    Haldane, Chloe E.; Ekhtiari, Seper; de SA, Darren; Simunovic, Nicole

    2017-01-01

    Abstract The purpose of this systematic review is to report current preoperative assessment for femoroacetabular impingement (FAI) including physical examination and imaging modalities prior to hip arthroscopy, and report current imaging measures used in the diagnosis of FAI. The electronic databases MEDLINE, EMBASE and PubMed were searched and screened in duplicate for relevant studies. Data regarding patient demographics, non-operative treatment, preoperative assessment including physical examination and imaging prior to hip arthroscopy were abstracted. Study quality was assessed in duplicate using the Methodological Index for Non-Randomized Studies criteria. Sixty-eight studies of fair quality evidence that involved a total of 5125 patients (5400 hips) were included. In total, 56% of all patients were male and mean age was 36 years (SD ± 10.0). Within physical examination, FADIR impingement testing was reported in 57% of patients. All included studies reported plain radiographic imaging as a component of preoperative assessment with anterior–posterior pelvis view being the most commonly reported view, followed by the cross-table lateral and Dunn views. Magnetic resonance imaging was obtained for 52% of included patients and computed tomography for 26% of patients. The most commonly reported measure within imaging for the diagnosis of cam type impingement was alpha angle (66%), whereas for pincer type impingement, the cross-over sign (48%) was most reported. Preoperative assessment is underreported in the FAI literature. Improved reporting is warranted to develop a more consistent and validated diagnostic algorithm for FAI to enhance patient selection. Level of evidence: Level IV, Systematic Review of Level I–IV Studies. PMID:28948032

  9. Single minimum incision endoscopic radical nephrectomy for renal tumors with preoperative virtual navigation using 3D-CT volume-rendering

    Directory of Open Access Journals (Sweden)

    Shioyama Yasukazu

    2010-04-01

    Full Text Available Abstract Background Single minimum incision endoscopic surgery (MIES involves the use of a flexible high-definition laparoscope to facilitate open surgery. We reviewed our method of radical nephrectomy for renal tumors, which is single MIES combined with preoperative virtual surgery employing three-dimensional CT images reconstructed by the volume rendering method (3D-CT images in order to safely and appropriately approach the renal hilar vessels. We also assessed the usefulness of 3D-CT images. Methods Radical nephrectomy was done by single MIES via the translumbar approach in 80 consecutive patients. We performed the initial 20 MIES nephrectomies without preoperative 3D-CT images and the subsequent 60 MIES nephrectomies with preoperative 3D-CT images for evaluation of the renal hilar vessels and the relation of each tumor to the surrounding structures. On the basis of the 3D information, preoperative virtual surgery was performed with a computer. Results Single MIES nephrectomy was successful in all patients. In the 60 patients who underwent 3D-CT, the number of renal arteries and veins corresponded exactly with the preoperative 3D-CT data (100% sensitivity and 100% specificity. These 60 nephrectomies were completed with a shorter operating time and smaller blood loss than the initial 20 nephrectomies. Conclusions Single MIES radical nephrectomy combined with 3D-CT and virtual surgery achieved a shorter operating time and less blood loss, possibly due to safer and easier handling of the renal hilar vessels.

  10. Relationship Between Preoperative Sarcopenia Status and Immuno-nutritional Parameters in Patients with Early-stage Non-small Cell Lung Cancer.

    Science.gov (United States)

    Shoji, Fumihiro; Matsubara, Taichi; Kozuma, Yuka; Haratake, Naoki; Akamine, Takaki; Takamori, Shinkichi; Katsura, Masakazu; Toyokawa, Gouji; Okamoto, Tatsuro; Maehara, Yoshihiko

    2017-12-01

    Although the skeletal muscle in the region of the third lumbar vertebra (L3) is generally assessed in order to judge sarcopenia, not every patient with non-small cell lung cancer (NSCLC) undergoes computed tomography including the L3 region. We hypothesized that immuno-nutritional parameters could predict the existence of sarcopenia in patients with NSCLC. The aim of this study was to retrospectively investigate the correlation between preoperative sarcopenia and immuno-nutritional parameters in patients with early-stage NSCLC. We selected 147 of patients with pathological stage I NSCLC who underwent preoperative measurement of immuno-nutritional parameters and CT including the L3 region. Preoperative sarcopenia was significantly associated with female gender (p=0.0003) and poor prognosis (p=0.0322). In Kaplan-Meier analysis of overall survival (OS) by preoperative sarcopenia status, the sarcopenic group had significantly shorter OS than the non-sarcopenic group (5-year OS: 87.27% vs. 77.37%, p=0.0131, log-rank test). In multivariate analysis, the preoperative sarcopenia status (hazard ratio=5.138; 95% confidence interval=2.305-11.676; psarcopenia status was significantly related to controlling nutritional status score (p=0.0071) and Geriatric Nutritional Risk Index (GNRI) (psarcopenia status and GNRI (r=0.348, psarcopenia which was associated with poor outcome in patients with early-stage NSCLC. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  11. Axial weak currents in the Wess-Zumino term

    International Nuclear Information System (INIS)

    Fujikawa, Kazuo.

    1985-03-01

    The conventional axial gauging of the Wess-Zumino term leads to the results which do not necessarily agree with the expectations on the basis of quark level Ward-Takahashi identities. This discrepancy arises from the fact that the quark level anomalous identities reflect the short distance structure of QCD, whereas the gauging of the Wess-Zumino term reflects the axial symmetry in the spontaneously broken chiral phase. The low energy theorem for axial weak fields is not sharply defined, in contrast to the case of vector fields where no such complications arise. (author)

  12. Efficacy of Acupuncture in Reducing Preoperative Anxiety: A Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Hyojeong Bae

    2014-01-01

    Full Text Available Background. Acupuncture has been shown to reduce preoperative anxiety in several previous randomized controlled trials (RCTs. In order to assess the preoperative anxiolytic efficacy of acupuncture therapy, this study conducted a meta-analysis of an array of appropriate studies. Methods. Four electronic databases (MEDLINE, EMBASE, CENTRAL, and CINAHL were searched up to February 2014. In the meta-analysis data were included from RCT studies in which groups receiving preoperative acupuncture treatment were compared with control groups receiving a placebo for anxiety. Results. Fourteen publications (N = 1,034 were included. Six publications, using the State-Trait Anxiety Inventory-State (STAI-S, reported that acupuncture interventions led to greater reductions in preoperative anxiety relative to sham acupuncture (mean difference = 5.63, P < .00001, 95% CI [4.14, 7.11]. Further eight publications, employing visual analogue scales (VAS, also indicated significant differences in preoperative anxiety amelioration between acupuncture and sham acupuncture (mean difference = 19.23, P < .00001, 95% CI [16.34, 22.12]. Conclusions. Acupuncture therapy aiming at reducing preoperative anxiety has a statistically significant effect relative to placebo or nontreatment conditions. Well-designed and rigorous studies that employ large sample sizes are necessary to corroborate this finding.

  13. The efficiency of aspheric intraocular lens according to biometric measurements.

    Science.gov (United States)

    Whang, Woong-Joo; Piao, Junjie; Yoo, Young-Sik; Joo, Choun-Ki; Yoon, Geunyoung

    2017-01-01

    To analyze internal spherical aberration in pseudophakic eyes that underwent aspheric intraocular lens (IOL) implantation, and to investigate the relationships between biometric data and the effectiveness of aspheric IOL implantation. This retrospective study included 40 eyes of 40 patients who underwent implantation of an IOL having a negative spherical aberration of -0.20 μm (CT ASPHINA 509M; Carl Zeiss Meditec Inc., Germany). The IOLMaster (version 5.0; Carl Zeiss AG, Germany) was used for preoperative biometric measurements (axial length, anterior chamber depth, central corneal power) and the measurement of postoperative anterior chamber depth. The spherical aberrations were measured preoperatively and 3 months postoperatively using the iTrace (Tracey Technologies, Houston, TX, USA) at a pupil diameter of 5.0 mm. We investigated the relationships between preoperative biometric data and postoperative internal spherical aberration, and compared biometric measurements between 2 subgroups stratified according to internal spherical aberration (spherical aberration ≤ -0.06 μm vs. spherical aberration > -0.06 μm). The mean postoperative internal spherical aberration was -0.087 ± 0.063 μm. Preoperative axial length and residual total spherical aberration showed statistically significant correlations with internal spherical aberration (p = 0.041, 0.002). Preoperative axial length, postoperative anterior chamber depth, IOL power, and residual spherical aberration showed significant differences between the 2 subgroups stratified according to internal spherical aberration (p = 0.020, 0.029, 0.048, 0.041 respectively). The corrective effect of an aspheric IOL is influenced by preoperative axial length and postoperative anterior chamber depth. Not only the amount of negative spherical aberration on the IOL surface but also the preoperative axial length should be considered to optimize spherical aberration after aspheric IOL implantation.

  14. Clinical significance of CT in the preoperative diagnosis of the staging of rectal cancer patients

    International Nuclear Information System (INIS)

    Itano, Satoshi; Fuchimoto, Sadanori; Hamada, Fumihiro; Kimura, Takanobu; Iwagaki, Hiromi; Maeda, Tetsuya; Orita, Kunzo

    1987-01-01

    The value of computed tomography (CT) in the preoperative clinical staging of rectal cancer was prospectively studied in 28 patients with macroscopically proven cancer. The CT studies were based on the previously established CT diagnostic criteria for wall invasion (S factor), lymph node metastases (N factor), and liver metastases (H factor). When macroscopic findings were used as the standard, the accuracy of CT was 61 % for S factor, 32 % for N factor, and 86 % for H factor. Using histological findings as the standard, the accuracy was 48 % for S factor and 16 % for N factor. Overall, CT had a high accuracy for H factor in all sites of cancer (75 % in the rectosigmoid, 86 % in the area above the peritoneal reflection, and 90 % in the area below the peritoneal reflection). For the other S and N factors, CT seemed to be of limited value in the preoperative diagnosis. (Namekawa, K.)

  15. CT virtual reality in the preoperative workup of malunited distal radius fractures: preliminary results

    International Nuclear Information System (INIS)

    Rieger, Michael; Gruber, Hannes; Jaschke, Werner R.; Gabl, Markus; Mallouhi, Ammar

    2005-01-01

    Our objective was to evaluate the usefulness of CT virtual preoperative planning in the surgical repositioning of malunited distal radius fracture. Eleven patients with malunited distal radius fracture underwent multislice CT of both wrists. A preoperative workup was performed in a virtual reality environment created from the CT data sets. Virtual planning comprised three main procedures, carrying out the virtual osteotomy of the radius, prediction of the final position of the distal radius after osteotomy and computer-assisted manufacturing of a repositioning device, which was later placed at the surgical osteotomy site to reposition objectively the distal radius fragment before fixation with the osteosynthesis. All patients tolerated the surgical procedure well. During surgery, the orthopedic surgeons were not required in any of the cases to alter the position of the distal radius that was determined by the repositioning device. At postoperative follow-up, the anatomic relationship of the distal radius was restored (radial inclination, 21.4 ; volar tilt, 10.3 ; ulnar variance, 0.5 mm). Clinically, a significant improvement of pronation (P=0.012), supination (P=0.01), flexion (P=0.001) and extension (P=0.006) was achieved. Pain decreased from 54 to 7 points. CT virtual reality is a valuable adjunct for the preoperative workup and surgical reposition of malunited distal radius fractures. (orig.)

  16. Trends in the incidence of benign pathological lesions at partial nephrectomy for presumed renal cell carcinoma in renal masses on preoperative computed tomography imaging. A single institute experience with 290 consecutive patients

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung-Hwan; Park, Sang-Un; Rha, Koon-Ho; Choi, Young-Deuk; Hong, Sung-Joon; Yang, Seung-Choul; Mah, Sang-Yol; Chung, Byung-Ha [Health System, Yonsei Univ., Seoul (Korea, Republic of)

    2010-06-15

    The aim of this study was to determine trends in the incidence of benign lesions in patients undergoing surgery for suspicious renal masses on preoperative computed tomography scan. The records of 1065 patients who underwent open consecutive partial nephrectomy (PN) or radical nephrectomy (RN) between January 2001 and December 2008 were reviewed. Patients who underwent PN during the periods 2001-2002, 2003-2004, 2005-2006, and 2007-2008 were assigned to groups 1, 2, 3 and 4, respectively. The frequencies of benign and malignant lesions in these groups were assessed according to size and histology subtypes. The ratio of PN to RN was 12.4%, 18.3%, 24.3% and 37.2% in groups 1, 2, 3 and 4, respectively (P<0.05). The mean size of resected lesions was 2.6 cm (range 0.8-6.2 cm). Of the 290 cases, histopathology revealed benign findings in 52 (17.9%). Benign pathology was found in three of 18 cases (16.7%) in group 1, seven of 36 cases (19.4%) in group 2, 12 of 63 cases (19.0%) in group 3 and 30 of 173 cases (17.3%) in group 4. There was no significant difference in the frequency of benign histology among groups. PN, as opposed to RN, has shown a rising tendency over time. The frequency of benign pathology findings after PN for suspicious renal masses on preoperative computed tomography imaging has not decreased. Proper management should favor nephron-sparing surgery for renal lesions if such lesions can be removed satisfactorily with PN. (author)

  17. Oral and maxillofacial surgery with computer-assisted navigation system.

    Science.gov (United States)

    Kawachi, Homare; Kawachi, Yasuyuki; Ikeda, Chihaya; Takagi, Ryo; Katakura, Akira; Shibahara, Takahiko

    2010-01-01

    Intraoperative computer-assisted navigation has gained acceptance in maxillofacial surgery with applications in an increasing number of indications. We adapted a commercially available wireless passive marker system which allows calibration and tracking of virtually every instrument in maxillofacial surgery. Virtual computer-generated anatomical structures are displayed intraoperatively in a semi-immersive head-up display. Continuous observation of the operating field facilitated by computer assistance enables surgical navigation in accordance with the physician's preoperative plans. This case report documents the potential for augmented visualization concepts in surgical resection of tumors in the oral and maxillofacial region. We report a case of T3N2bM0 carcinoma of the maxillary gingival which was surgically resected with the assistance of the Stryker Navigation Cart System. This system was found to be useful in assisting preoperative planning and intraoperative monitoring.

  18. The Role of Preoperative Imaging in the Management of Nonsyndromic Lambdoid Craniosynostosis.

    Science.gov (United States)

    Ranganathan, Kavitha; Rampazzo, Antonio; Hashmi, Asra; Muraszko, Karin; Strahle, Jennifer; Vercler, Christian J; Buchman, Steven R

    2018-01-01

    The necessity of imaging for patients with craniosynostosis is controversial. Lambdoid synostosis is known to be associated with additional anomalies, but the role of imaging in this setting has not been established. The purpose of this study was to evaluate the impact of preoperative imaging on intraoperative and postoperative management among patients undergoing operative intervention for lambdoid craniosynostosis. A retrospective review of patients undergoing cranial vault remodeling for lambdoid craniosynostosis between January 2006 and 2014 was conducted. Patient demographics, age at computed tomography scan, age at surgery, results of the radiologic evaluation, operative technique, and modification of the diagnosis following the radiologic studies were analyzed. A pediatric neuroradiology and the surgical team interpreted the radiographs. The primary outcome was change in intraoperative or postoperative management based on imaging results. A total of 11 patients were diagnosed with lambdoid synostosis. Of these patients, 81.8% had abnormalities on imaging relevant to operative planning. The most common anomalies were Chiari I malformation (45%) and venous anomalies of the posterior fossa (36%). Preoperative imaging altered the management of 9 (81.8%) patients. Closer follow-up was required for 6 patients (54%). Suboccipital decompression was performed in 4 patients (36%). Venous anomalies were found in 4 patients (36%). The diagnosis was changed from positional plagiocephaly to lambdoid synostosis in 2 patients (18%). Given the frequency and significance of radiographic abnormalities in the setting of lamboid synostosis, preoperative imaging should be considered during the operative planning phase as it can affect postoperative and intraoperative management.

  19. FEAST 3.1: finite-element modeling of sheath deformation such as longitudinal ridging and collapse into axial gap

    Energy Technology Data Exchange (ETDEWEB)

    Wang, X.; Xu, Z.; Kim, Y-S.; Lai, L.; Cheng, G.; Xu, S. [Atomic Energy of Canada Limited, Mississauga, Ontario (Canada)

    2010-07-01

    During normal operation, the collapsible CANDU® fuel sheath deforms, especially, it may deform into longitudinal ridges or collapse instantaneously into the axial gaps between the end pellet and endcap or between two neighbouring pellets. These phenomena occur under certain conditions, such as the coolant pressure exceeding critical pressures for longitudinal ridging or axial collapse. Both longitudinal ridging and axial collapse phenomena result from plastic instability in the sheath under coolant pressure. Longitudinal ridging features one or multiple lobes or 'ridges' (outward from the sheath surface) formed along the sheath in the longitudinal direction. Axial collapse features a 'valley' around the sheath circumference. Both phenomena can lead to sheath overstrain, which in turn potentially leads to sheath failure. The LONGER code, which contains empirical correlations, has been used to predict the critical pressures for these two sheath deformation phenomena. To study fuel behaviour outside of the application ranges of the LONGER empirical correlations, a mechanistic model is needed. FEAST (Finite Element Analysis for Stresses) is an AECL computer code used to assess the structural integrity of the CANDU fuel element. The FEAST code has recently been developed (to Version 3.1) to model processes occurring during longitudinal ridge formation and instantaneous collapse into the axial gap. The new models include those for geometric non-linearity (large deformation, large material rotation), non-linear stress-strain curve for plastic deformation, Zr-4 sheath creep law, and variable Young’s Modulus etc. This paper describes the mechanistic model (FEAST 3.1) development for analyses of longitudinal ridging and instantaneous collapse into axial gap, and the comparison with the results from empirical correlations in LONGER. (author)

  20. FEAST 3.1: finite-element modeling of sheath deformation such as longitudinal ridging and collapse into axial gap

    International Nuclear Information System (INIS)

    Wang, X.; Xu, Z.; Kim, Y-S.; Lai, L.; Cheng, G.; Xu, S.

    2010-01-01

    During normal operation, the collapsible CANDU® fuel sheath deforms, especially, it may deform into longitudinal ridges or collapse instantaneously into the axial gaps between the end pellet and endcap or between two neighbouring pellets. These phenomena occur under certain conditions, such as the coolant pressure exceeding critical pressures for longitudinal ridging or axial collapse. Both longitudinal ridging and axial collapse phenomena result from plastic instability in the sheath under coolant pressure. Longitudinal ridging features one or multiple lobes or 'ridges' (outward from the sheath surface) formed along the sheath in the longitudinal direction. Axial collapse features a 'valley' around the sheath circumference. Both phenomena can lead to sheath overstrain, which in turn potentially leads to sheath failure. The LONGER code, which contains empirical correlations, has been used to predict the critical pressures for these two sheath deformation phenomena. To study fuel behaviour outside of the application ranges of the LONGER empirical correlations, a mechanistic model is needed. FEAST (Finite Element Analysis for Stresses) is an AECL computer code used to assess the structural integrity of the CANDU fuel element. The FEAST code has recently been developed (to Version 3.1) to model processes occurring during longitudinal ridge formation and instantaneous collapse into the axial gap. The new models include those for geometric non-linearity (large deformation, large material rotation), non-linear stress-strain curve for plastic deformation, Zr-4 sheath creep law, and variable Young’s Modulus etc. This paper describes the mechanistic model (FEAST 3.1) development for analyses of longitudinal ridging and instantaneous collapse into axial gap, and the comparison with the results from empirical correlations in LONGER. (author)

  1. An Efficient Estimation Method for Reducing the Axial Intensity Drop in Circular Cone-Beam CT

    Directory of Open Access Journals (Sweden)

    Lei Zhu

    2008-01-01

    Full Text Available Reconstruction algorithms for circular cone-beam (CB scans have been extensively studied in the literature. Since insufficient data are measured, an exact reconstruction is impossible for such a geometry. If the reconstruction algorithm assumes zeros for the missing data, such as the standard FDK algorithm, a major type of resulting CB artifacts is the intensity drop along the axial direction. Many algorithms have been proposed to improve image quality when faced with this problem of data missing; however, development of an effective and computationally efficient algorithm remains a major challenge. In this work, we propose a novel method for estimating the unmeasured data and reducing the intensity drop artifacts. Each CB projection is analyzed in the Radon space via Grangeat's first derivative. Assuming the CB projection is taken from a parallel beam geometry, we extract those data that reside in the unmeasured region of the Radon space. These data are then used as in a parallel beam geometry to calculate a correction term, which is added together with Hu’s correction term to the FDK result to form a final reconstruction. More approximations are then made on the calculation of the additional term, and the final formula is implemented very efficiently. The algorithm performance is evaluated using computer simulations on analytical phantoms. The reconstruction comparison with results using other existing algorithms shows that the proposed algorithm achieves a superior performance on the reduction of axial intensity drop artifacts with a high computation efficiency.

  2. Interventions for preoperative smoking cessation

    DEFF Research Database (Denmark)

    Thomsen, Thordis; Villebro, N.; Møller, Ann Merete

    2010-01-01

    Background Smokers have a substantially increased risk of postoperative complications. Preoperative smoking intervention may be effective in decreasing this incidence, and surgery may constitute a unique opportunity for smoking cessation interventions. Objectives The objective of this review...... was to assess the effect of preoperative smoking intervention on smoking cessation at the time of surgery and 12 months postoperatively and on the incidence of postoperative complications. Search strategy The specialized register of the Cochrane Tobacco Addiction Group was searched using the free text...... and keywords (surgery) or (operation) or (anaesthesia) or (anesthesia). MEDLINE, EMBASE and CINAHL were also searched, combining tobacco- and surgery-related terms. Most recent search April 2010. Selection criteria Randomized controlled trials that recruited people who smoked prior to surgery, offered...

  3. [Preoperative fasting guidelines: an update].

    Science.gov (United States)

    López Muñoz, A C; Busto Aguirreurreta, N; Tomás Braulio, J

    2015-03-01

    Anesthesiology societies have issued various guidelines on preoperative fasting since 1990, not only to decrease the incidence of lung aspiration and anesthetic morbidity, but also to increase patient comfort prior to anesthesia. Some of these societies have been updating their guidelines, as such that, since 2010, we now have 2 evidence-based preoperative fasting guidelines available. In this article, an attempt is made to review these updated guidelines, as well as the current instructions for more controversial patients such as infants, the obese, and a particular type of ophthalmic surgery. Copyright © 2014 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. Preoperative anxiety in children risk factors and non-pharmacological management.

    Science.gov (United States)

    Ahmed, Mohammad I; Farrell, Maureen A; Parrish, Katie; Karla, Aman

    2011-06-01

    It is important for anesthesiologists to appreciate the impact of preoperative anxiety in children. Not only does it cause suffering in many children prior to their surgical experience, it has a negative impact on their postoperative recovery and possibly long afterwards. Because of these concerns, continued research is warranted to seek ways of minimizing their fears in the perioperative setting. In this review, we will examine the risk factors for preoperative anxiety, tools for quantifying children and parent's anxiety, and strategies that may play a part in decreasing preoperative anxiety. Variables, which influence preoperative anxiety in children, include their age, temperament, prior hospital experience and parent coping abilities. This review will also explore issues surrounding parental presence during a child's anesthesia induction and how understanding child development can enhance their cooperativeness during the preoperative period, especially during anesthesia induction. Non-pharmacological interventions as a means of decreasing pediatric anxiety will be explored. Finally recent trends and new directions will be touched upon.

  5. Magmatic controls on axial relief and faulting at mid-ocean ridges

    Science.gov (United States)

    Liu, Zhonglan; Buck, W. Roger

    2018-06-01

    Previous models do not simultaneously reproduce the observed range of axial relief and fault patterns at plate spreading centers. We suggest that this failure is due to the approximation that magmatic dikes open continuously rather than in discrete events. During short - lived events, dikes open not only in the strong axial lithosphere but also some distance into the underlying weaker asthenosphere. Axial valley relief affects the partitioning of magma between the lithosphere and asthenosphere during diking events. The deeper the valley, the more magma goes into lithospheric dikes in each event and so the greater the average opening rate of those dikes. The long-term rate of lithospheric dike opening controls faulting rate and axial depth. The feedback between axial valley depth D and lithospheric dike opening rate allows us to analytically relate steady-state values of D to lithospheric thickness HL and crustal thickness HC. A two-dimensional model numerical model with a fixed axial lithospheric structure illustrates the analytic model implications for axial faulting. The predictions of this new model are broadly consistent with global and segment-scale trends of axial depth and fault patterns with HL and HC.

  6. Design and axial optimization of nuclear fuel for BWR reactors

    International Nuclear Information System (INIS)

    Garcia V, M.A.

    2006-01-01

    axial design of fuel assemblies is explained, beginning with the development of the optimization system by means of computational simulators, its also establish the evaluation parameters and the operation limits guided to the application of the tabu method. Chapter 5: Here the developed methodology applications are described and explained, the carried out modifications are analyzed in the optimization system and those obtained results are examined. Comments are also added and it ends with the conclusions to this work. (Author)

  7. Radial loads and axial thrusts on centrifugal pumps

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    The proceedings of a seminar organised by the Power Industries Division of the IMechE are presented in this text. Complete contents: Review of parameters influencing hydraulic forces on centrifugal impellers; The effect of fluid forces at various operation conditions on the vibrations of vertical turbine pumps; A review of the pump rotor axial equilibrium problem - some case studies; Dynamic hydraulic loading on a centrifugal pump impeller; Experimental research on axial thrust loads of double suction centrifugal pumps; A comparison of pressure distribution and radial loads on centrifugal pumps; A theoretical and experimental investigation of axial thrusts within a multi-stage centrifugal pump

  8. The effects of initial rise and axial loads on MEMS arches

    KAUST Repository

    Tella, Sherif Adekunle

    2017-04-07

    Arch microbeams have been utilized and proposed for many uses over the past few years due to their large tunability and bistability. However, recent experimental data have shown different mechanical behavior of arches when subjected to axial loads. This paper aims to investigate in depth the influence of the competing effects of initial rise and axial loads on the mechanical behavior of micromachined arches; mainly their static deflection and resonant frequencies. Based on analytical solutions, the static response and eigenvalue problems are analyzed for various values of initial rises and axial loads. Universal curves showing the variation of the first three resonance frequencies of the arch are generated for various values of initial rise under both tensile and compressive axial loads. This study shows that increasing the tensile or compressive axial loads for different values of initial rise may lead to either increase in the stiffness of the beam or initial decrease in the stiffness, which later increases as the axial load is increased depending on the dominant effect of the initial rise of the arch and the axial load. The obtained universal curves represent useful design tools to predict the tunability of arches under axial loads for various values of initial rises. The use of the universal curves is demonstrated with an experimental case study. Analytical formulation is developed to predict the point of minimum where the trend of the resonance frequency versus axial loads changes qualitatively due to the competing effects of axial loads and initial curvature.

  9. Is there a need for preoperative imaging of the internal mammary recipient site for autologous breast reconstruction?

    Science.gov (United States)

    Rozen, Warren M; Alonso-Burgos, Alberto; Murray, Alice C A; Whitaker, Iain S

    2013-01-01

    Preoperative imaging of recipient-site vasculatur in autologous breast reconstruction may potentiate improved outcomes through the identification of individual variations in vascular architecture. There are a range of both normal and pathologic states which can substantially affect the internal mammary vessels in particular, and the identification of these preoperatively may significantly affect operative approach. There are a range of imaging modalities available, with ultrasound particularly useful, and computed tomography angiography (CTA) evolving as a useful option, albeit with radiation exposure. The benefits of CTA must be balanced against its risks, which include contrast nephrotoxicity and allergic reactions, and radiation exposure. The radiation risk with thoracic imaging is substantially higher than that for donor sites, such as the abdominal wall, with reasons including exposure of the contralateral breast to radiation (with a risk of contralateral breast cancer in this population 2 to 6 times higher than that of primary breast cancer, reaching a 20-year incidence of 15%), as well as proximity to the thyroid gland. Current evidence suggests that although many cases may not warrant such imaging because of risk, the benefits of preoperative CTA in selected patients may outweigh the risks of exposure, prompting an individualized approach.

  10. [Preoperative imaging/operation planning for liver surgery].

    Science.gov (United States)

    Schoening, W N; Denecke, T; Neumann, U P

    2015-12-01

    The currently established standard for planning liver surgery is multistage contrast media-enhanced multidetector computed tomography (CM-CT), which as a rule enables an appropriate resection planning, e.g. a precise identification and localization of primary and secondary liver tumors as well as the anatomical relation to extrahepatic and/or intrahepatic vascular and biliary structures. Furthermore, CM-CT enables the measurement of tumor volume, total liver volume and residual liver volume after resection. Under the condition of normal liver function a residual liver volume of 25 % is nowadays considered sufficient and safe. Recent studies in patients with liver metastases of colorectal cancer showed a clear staging advantage of contrast media-enhanced magnetic resonance imaging (CM-MRI) versus CM-CT. In addition, most recent data showed that the use of liver-specific MRI contrast media further increases the sensitivity and specificity of detection of liver metastases. This imaging technology seems to lead closer to the ideal "one stop shopping" diagnostic tool in preoperative planning of liver resection.

  11. Fatigue reliability of structural members under combined axial mean and alternating stresses for AISI 1018, 1038, 4130 and 4340 steels

    International Nuclear Information System (INIS)

    Kececioglu, D.

    1977-01-01

    The failure governing strength distributions of round specimens subjected to a mean axial stress onto which alternating tensile and compressive axial stresses are superimposed, for 10 6 and 2x10 6 cycles of operation, are determined. AISI 1018, 1038, 4130 and 4340 steel 3/8-in. diameter, specimens are tested on an axial, Baldwin-Lima-Hamilton Universal Fatigue Testing Machine. Staircase-testing is used to determine the endurance strength distributions at various ratios of alternating to mean tensile stresses. Testing is accomplished at a sufficient number of ratios to enable the construction of a distributional, statistical Goodman strength diagram for each one of the four steels. A digital computer program of the Reliability Engineering Research Laboratory at The University of Arizona, Program LEAST, is used to determine the equation of the distributional Goodman diagram which best fits the loci of the experimental data at stress ratios between zero and infinity

  12. Quasi-renormalization of the axial vector model

    International Nuclear Information System (INIS)

    Schweda, M.

    1979-01-01

    Using the regulator-free BPHZL renormalization scheme the problem of anomalies in a massive axial vector meson model is reinvestigated. The Adler-Bardeen-Bell-Jackiw anomaly introduces some impressive modifications: the nontrivial self-energy and the counterterm of the longitudinal part of the axial vector field depend on the anomaly via the anomalous Ward identity. The investigations are based on a Fermi-type gauge. (author)

  13. Long-term effects of a preoperative smoking cessation programme

    DEFF Research Database (Denmark)

    Villebro, Nete Munk; Pedersen, Tom; Møller, Ann M

    2008-01-01

    Preoperative smoking intervention programmes reduce post-operative complications in smokers. Little is known about the long-term effect upon smoking cessation.......Preoperative smoking intervention programmes reduce post-operative complications in smokers. Little is known about the long-term effect upon smoking cessation....

  14. Effect of axial heat flux distribution on CHF

    Energy Technology Data Exchange (ETDEWEB)

    Park, Cheol

    2000-10-01

    Previous investigations for the effect of axial heat flux distributions on CHF and the prediction methods are reviewed and summarized. A total of 856 CHF data in a tube with a non-uniform axial heat flux distribution has been compiled from the articles and analyzed using the 1995 Groeneveld look-up table. The results showed that two representative correction factors, K5 of the look-up table and Tongs F factor, can be applied to describe the axial heat flux distribution effect on CHF. However, they overpredict slightly the measured CHF, depending on the quality and flux peak shape. Hence, a corrected K5 factor, which accounts for the axial heat flux distribution effect is suggested to correct these trends. It predicted the CHF power for the compiled data with an average error of 1.5% and a standard deviation of 10.3%, and also provides a reasonable prediction of CHF locations.

  15. Hysteretic Models Considering Axial-Shear-Flexure Interaction

    Science.gov (United States)

    Ceresa, Paola; Negrisoli, Giorgio

    2017-10-01

    Most of the existing numerical models implemented in finite element (FE) software, at the current state of the art, are not capable to describe, with enough reliability, the interaction between axial, shear and flexural actions under cyclic loading (e.g. seismic actions), neglecting crucial effects for predicting the nature of the collapse of reinforced concrete (RC) structural elements. Just a few existing 3D volume models or fibre beam models can lead to a quite accurate response, but they are still computationally inefficient for typical applications in earthquake engineering and also characterized by very complex formulation. Thus, discrete models with lumped plasticity hinges may be the preferred choice for modelling the hysteretic behaviour due to cyclic loading conditions, in particular with reference to its implementation in a commercial software package. These considerations lead to this research work focused on the development of a model for RC beam-column elements able to consider degradation effects and interaction between the actions under cyclic loading conditions. In order to develop a model for a general 3D discrete hinge element able to take into account the axial-shear-flexural interaction, it is necessary to provide an implementation which involves a corrector-predictor iterative scheme. Furthermore, a reliable constitutive model based on damage plasticity theory is formulated and implemented for its numerical validation. Aim of this research work is to provide the formulation of a numerical model, which will allow implementation within a FE software package for nonlinear cyclic analysis of RC structural members. The developed model accounts for stiffness degradation effect and stiffness recovery for loading reversal.

  16. Role of Pre-Operative Blood Transfusion and Subcutaneous Fat Thickness as Risk Factors for Surgical Site Infection after Posterior Thoracic Spine Stabilization.

    Science.gov (United States)

    Osterhoff, Georg; Burla, Laurin; Werner, Clément M L; Jentzsch, Thorsten; Wanner, Guido A; Simmen, Hans-Peter; Sprengel, Kai

    2015-06-01

    Surgical site infections (SSIs) increase morbidity and mortality rates and generate additional cost for the healthcare system. Pre-operative blood transfusion and the subcutaneous fat thickness (SFT) have been described as risk factors for SSI in other surgical areas. The purpose of this study was to assess the impact of pre-operative blood transfusion and the SFT on the occurrence of SSI in posterior thoracic spine surgery. In total, 244 patients (median age 55 y; 97 female) who underwent posterior thoracic spine fusions from 2008 to 2012 were reviewed retrospectively. Patient-specific characteristics, pre-operative hemoglobin concentration/hematocrit values, the amount of blood transfused, and the occurrence of a post-operative SSI were documented. The SFT was measured on pre-operative computed tomography scans. Surgical site infection was observed in 26 patients (11%). The SFT was 13 mm in patients without SSI and 14 mm in those with infection (p=0.195). The odds ratio for patients with pre-operative blood transfusion to present with SSI was 3.1 (confidence interval [CI] 1.4-7.2) and 2.7 (CI 1.1-6.4) when adjusted for age. There was no difference between the groups with regard to pre-operative hemoglobin concentration (p=0.519) or hematocrit (p=0.908). The SFT did not differ in the two groups. Allogeneic red blood cell transfusion within 48 h prior to surgery was an independent risk factor for SSI after posterior fusion for the fixation of thoracic spine instabilities. Pre-operative blood transfusion tripled the risk, whereas SFT had no influence on the occurrence of SSI.

  17. [Usefulness of computed tomography and magnetic resonance in the preoperative diagnosis for hyperparathyroidism].

    Science.gov (United States)

    Pino Rivero, V; Pantoja Hernández, C G; González Palomino, A; Trinidad Ruíz, G; Marcos García, M; Keituqwa Yáñez, T; Pardo Romero, G; Blasco Huelva, A

    2005-01-01

    Sonnography and Tc-99m sestamibi scintigraphy are the most requested preoperative imaging tests nowdays in the surgery of hyperparathyroidism. The aim of our article is to know if Computerized Tomography (CT) and Magnetic Resonance Imaging (MRI) are useful as a location study and in which cases it would be more justified to ask these radiologic techniques. For that we report our results with 29 patients at all diagnosed as hyperparathyroidism (26 primary forms and 3 secondary ones) and operated by our E.N.T. Department later. On 20 of them a cervical CT was asked before the parathyroidectomy and on the rest 9, a MRI with sensitivities of 65% and 88.9% respectively. We think both complementary explorations must not be solicited by routine but they can represent a help in the cases in that sonnography and scintigraphy are not able to show the possible adenoma or hiperplasia, particularly in recurrent hyperparathyroidisms, reinterventions or suspect of parathyroid glands in an atypical location.

  18. PREOPERATIVE ENDOSCOPIC MARKING OF UNPALPABLE COLONIC TUMORS

    Directory of Open Access Journals (Sweden)

    A. L. Goncharov

    2013-01-01

    Full Text Available The identification of small colon lesions is one of the major problems in laparoscopic colonic resection.Research objective: to develop a technique of visualization of small tumors of a colon by preoperative endoscopic marking of a tumor.Materials and methods. In one day prior to operation to the patient after bowel preparation the colonoscopy is carried out. In the planned point near tumor on antimesentery edge the submucous infiltration of marking solution (Micky Sharpz blue tattoo pigment, UK is made. The volume of entered solution of 1–3 ml. In only 5 months of use of a technique preoperative marking to 14 patients with small (the size of 1–3 cm malignant tumors of the left colon is performed.Results. The tattoo mark was well visualized by during operation at 13 of 14 patients. In all cases we recorded no complications. Time of operation with preoperative marking averaged 108 min, that is significantly less in comparison with average time of operation with an intra-operative colonoscopy – 155 min (р < 0.001.Conclusions. The first experience of preoperative endoscopic marking of non palpable small tumors of a colon is encouraging. Performance of a technique wasn't accompanied by complications and allowed to reduce significantly time of operation and to simplify conditions of performance of operation.

  19. Design optimization of axial flow hydraulic turbine runner: Part II - multi-objective constrained optimization method

    Science.gov (United States)

    Peng, Guoyi; Cao, Shuliang; Ishizuka, Masaru; Hayama, Shinji

    2002-06-01

    This paper is concerned with the design optimization of axial flow hydraulic turbine runner blade geometry. In order to obtain a better design plan with good performance, a new comprehensive performance optimization procedure has been presented by combining a multi-variable multi-objective constrained optimization model with a Q3D inverse computation and a performance prediction procedure. With careful analysis of the inverse design of axial hydraulic turbine runner, the total hydraulic loss and the cavitation coefficient are taken as optimization objectives and a comprehensive objective function is defined using the weight factors. Parameters of a newly proposed blade bound circulation distribution function and parameters describing positions of blade leading and training edges in the meridional flow passage are taken as optimization variables.The optimization procedure has been applied to the design optimization of a Kaplan runner with specific speed of 440 kW. Numerical results show that the performance of designed runner is successfully improved through optimization computation. The optimization model is found to be validated and it has the feature of good convergence. With the multi-objective optimization model, it is possible to control the performance of designed runner by adjusting the value of weight factors defining the comprehensive objective function. Copyright

  20. Continuous millennial decrease of the Earth's magnetic axial dipole

    Science.gov (United States)

    Poletti, Wilbor; Biggin, Andrew J.; Trindade, Ricardo I. F.; Hartmann, Gelvam A.; Terra-Nova, Filipe

    2018-01-01

    Since the establishment of direct estimations of the Earth's magnetic field intensity in the first half of the nineteenth century, a continuous decay of the axial dipole component has been observed and variously speculated to be linked to an imminent reversal of the geomagnetic field. Furthermore, indirect estimations from anthropologically made materials and volcanic derivatives suggest that this decrease began significantly earlier than direct measurements have been available. Here, we carefully reassess the available archaeointensity dataset for the last two millennia, and show a good correspondence between direct (observatory/satellite) and indirect (archaeomagnetic) estimates of the axial dipole moment creating, in effect, a proxy to expand our analysis back in time. Our results suggest a continuous linear decay as the most parsimonious long-term description of the axial dipole variation for the last millennium. We thus suggest that a break in the symmetry of axial dipole moment advective sources occurred approximately 1100 years earlier than previously described. In addition, based on the observed dipole secular variation timescale, we speculate that the weakening of the axial dipole may end soon.

  1. Laminoplasty Does not Lead to Worsening Axial Neck Pain in the Properly Selected Patient With Cervical Myelopathy: A Comparison With Laminectomy and Fusion.

    Science.gov (United States)

    Stephens, Byron F; Rhee, John M; Neustein, Thomas M; Arceo, Rafael

    2017-12-15

    Retrospective cohort study of prospectively collected data. To determine if laminoplasty (LP) is associated with worsening axial neck pain in patients with multilevel cervical myelopathy, and to compare neck pain, clinical outcomes, and radiographic measures in a group undergoing laminectomy and fusion (LF). Postoperative new or worsening axial neck pain is commonly cited as a major disadvantage of laminoplasty. However, there remains a paucity of corroborative data from large series. Following institutional review board approval, we reviewed the medical records, radiographs, and prospective clinical outcomes database of 85 patients undergoing LP and 52 patients undergoing LF for cervical myelopathy with minimum 1-year radiographic follow-up and average clinical follow-up of 18.5 months. LP was performed in those with neutral to lordotic C2-7 alignment and who did not complain of diffuse axial pain. Otherwise, LF was performed. Clinical outcomes included visual analogue score (VAS)-neck pain, VAS-total pain, neck disability index (NDI), short form 36, modified Japanese Orthopaedic Association (mJOA), and several radiographic parameters. VAS-neck did not worsen in LP (-0.2, P = 0.54) and did improve in LF (-2.0, P = 0.0013). VAS-total improved significantly in both groups (LF -1.04 ± 0.52, P = 0.05; LP -1.4 ± 0.51, P = 0.008). NDI improved in both groups, but was significant in only LP (LP decreased 6.79 ± 2.25, P = 0.0032; LF decreased 4.01 ± 3.05, P = 0.19). mJOA scores improved significantly in both groups (LP improved 2.89 ± 0.27, P cervical lordosis in both groups that was significant in LP (LP 2.92° loss, P = 0.0181; LF 1.25° loss, P = 0.53). In a carefully selected group of myelopathic patients without significant diffuse axial pain preoperatively and appropriate sagittal alignment, laminoplasty did not lead to worsening axial neck pain, and it was associated with significant improvements in other

  2. Preoperative embolization in surgical treatment of spinal metastases

    DEFF Research Database (Denmark)

    Clausen, Caroline; Dahl, Benny; Frevert, Susanne Christiansen

    2015-01-01

    PURPOSE: To assess whether preoperative transcatheter arterial embolization of spinal metastases reduces blood loss, the need for transfusion with allogeneic red blood cells (RBCs), and surgery time in the surgical treatment of patients with symptomatic metastatic spinal cord compression. MATERIALS......L) versus 902 mL (SD, 416 mL). CONCLUSIONS: Preoperative embolization in patients with symptomatic spinal metastasis independent of primary tumor diagnosis did not reduce intraoperative blood loss and allogeneic RBC transfusion significantly but did reduce the surgery time. A small reduction...... instrumentation and randomly assigned to either preoperative embolization (n = 23) or a control group (n = 22). The primary outcome was intraoperative blood loss. Secondary outcomes were perioperative blood loss, allogeneic RBC transfusion, and surgery time. Analyses were performed by intention-to-treat. RESULTS...

  3. The significance of preoperative CT during arterial portography in surgical treatment of patients with hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Hayashi, Takafumi; Suzuki, Kazunori; Konishi, Ichiro; Sato, Naoki; Yamashiro, Yutaka; Yamaguchi, Yumi; Hirooka, Yasuaki; Kaibara, Nobuaki

    1999-01-01

    This study was designed to elucidate the significance of preoperative computed tomography during arterial portography (CTAP) in surgical treatment of hepatocellular carcinoma (HCC). Eighteen patients with HCC whose minute lesions had been pointed out by CTAP preoperatively (CTAP positive group) were compared with another eight patients with HCC having postoperative recurrence in a region at where no tumors had been detected by preoperative CTAP (CTAP negative group) for preoperative location of tumor and postoperative pattern of recurrence. In the CTAP positive group, 11 patients had recurrence and the remaining seven patients had not. Disease-free periods up to recurrences were 8.7 months in an average in the 11 CTAP positive patients and 16.6 months in the CTAP-negative group, showing a significantly shorter interval in the CTAP positive patients. In recurred cases from the CTAP positive group, tumors identified by imaging procedures other than CTAP were solitary in four and multiple in seven cases, while all solitary in non-recurred cases. In the recurred CTAP positive cases, actual recurrence occurred in the same segment where a tumor had been pointed out by CTAP alone in five out of six cases of solitary recurrence; or involved the same segment where CTAP detected tumor (s) in four out of five cases of multiple recurrence. It is indicated that the possibility of postoperative recurrence of HCC is high in cases having minute lesions visualized by CTAP alone in addition to multiple lesions visualized by imaging procedures other than CTAP. We think that periodical imaging methods including CTAP are required for HCC patients. (author)

  4. Preoperative High-Dose Steroid Has Long-Term Beneficial Effects for Myasthenia Gravis

    Directory of Open Access Journals (Sweden)

    Syuichi Tetsuka

    2013-01-01

    Full Text Available Previous studies addressing preoperative steroid treatment have revealed that control of myasthenia gravis (MG with steroids prior to surgery appeared to stabilize postoperative status. The purpose of our study was to clarify the clinical benefits of the preoperative programmed high-dose steroid treatment on the long-term outcomes of MG patients. We retrospectively reviewed the records of 171 MG patients who were followed up after undergoing thymectomy in our hospital between 1988 and 2006. One hundred and thirteen patients in the programmed treatment group had received preoperative steroid treatment, while 58 patients received no steroid treatment during the preoperative period. Clinical remission, which was defined as the achievement of the modified pharmacologic remission (PR for at least 1 year, and clinical benefits were compared between the two groups. With regard to the remission after thymectomy, Kaplan-Meier life-table curves for patients in the preoperative steroid treatment group versus those for patients in the no steroid preoperative treatment group revealed a significantly higher probability of the PR in the preoperative steroid treatment group (log-rank test, P<0.01. This study might be the first, as per our knowledge, to indicate that preoperative programmed high-dose steroid treatment has long-term beneficial effects for MG patients.

  5. Effect of Preoperative Pain on Inferior Alveolar Nerve Block.

    Science.gov (United States)

    Aggarwal, Vivek; Singla, Mamta; Subbiya, Arunajatesan; Vivekanandhan, Paramasivam; Sharma, Vikram; Sharma, Ritu; Prakash, Venkatachalam; Geethapriya, Nagarajan

    2015-01-01

    The present study tested the hypothesis that the amount and severity of preoperative pain will affect the anesthetic efficacy of inferior alveolar nerve block (IANB) in patients with symptomatic irreversible pulpitis. One-hundred seventy-seven adult volunteer subjects, actively experiencing pain in a mandibular molar, participated in this prospective double-blind study carried out at 2 different centers. The patients were classified into 3 groups on the basis of severity of preoperative pain: mild, 1-54 mm on the Heft-Parker visual analog scale (HP VAS); moderate, 55-114 mm; and severe, greater than 114 mm. After IANB with 1.8 mL of 2% lidocaine, endodontic access preparation was initiated. Pain during treatment was recorded using the HP VAS. The primary outcome measure was the ability to undertake pulp access and canal instrumentation with no or mild pain. The success rates were statistically analyzed by multiple logistic regression test. There was a significant difference between the mild and severe preoperative pain group (P = .03). There was a positive correlation between the values of preoperative and intraoperative pain (r = .2 and .4 at 2 centers). The amount of preoperative pain can affect the anesthetic success rates of IANB in patients with symptomatic irreversible pulpitis.

  6. Effect of Preoperative Pain on Inferior Alveolar Nerve Block

    Science.gov (United States)

    Aggarwal, Vivek; Singla, Mamta; Subbiya, Arunajatesan; Vivekanandhan, Paramasivam; Sharma, Vikram; Sharma, Ritu; Prakash, Venkatachalam; Geethapriya, Nagarajan

    2015-01-01

    The present study tested the hypothesis that the amount and severity of preoperative pain will affect the anesthetic efficacy of inferior alveolar nerve block (IANB) in patients with symptomatic irreversible pulpitis. One-hundred seventy-seven adult volunteer subjects, actively experiencing pain in a mandibular molar, participated in this prospective double-blind study carried out at 2 different centers. The patients were classified into 3 groups on the basis of severity of preoperative pain: mild, 1–54 mm on the Heft-Parker visual analog scale (HP VAS); moderate, 55–114 mm; and severe, greater than 114 mm. After IANB with 1.8 mL of 2% lidocaine, endodontic access preparation was initiated. Pain during treatment was recorded using the HP VAS. The primary outcome measure was the ability to undertake pulp access and canal instrumentation with no or mild pain. The success rates were statistically analyzed by multiple logistic regression test. There was a significant difference between the mild and severe preoperative pain group (P = .03). There was a positive correlation between the values of preoperative and intraoperative pain (r = .2 and .4 at 2 centers). The amount of preoperative pain can affect the anesthetic success rates of IANB in patients with symptomatic irreversible pulpitis. PMID:26650491

  7. K{sub I}-T estimations for embedded flaws in pipes - Part I: Axially oriented cracks

    Energy Technology Data Exchange (ETDEWEB)

    Qian Xudong, E-mail: cveqx@nus.edu.s [Department of Civil Engineering, National University of Singapore, 1 Engineering Drive 2, Singapore 117576 (Singapore)

    2010-04-15

    This study reports a numerical investigation on the linear-elastic K{sub I} and T-stress values over the front of elliptical cracks axially embedded in the wall of a pipe/cylindrical structure, under a uniform pressure applied on the inner surface of the pipe. The numerical procedure employs an interaction integral approach to compute the linear-elastic stress intensity factor (SIF) K{sub I} and T-stress values from very detailed crack-front meshes. The verification study confirms the accuracy of the adopted numerical procedure in computing the K{sub I} values based on existing results for external axial surface cracks in the wall of a cylindrical structure. The parametric investigation covers a wide range of geometric parameters including: the wall thickness to the inner radius ratio of the pipe (t/R{sub i}), the crack depth over the wall thickness ratio (a/t), the crack aspect ratio (a/c) and the crack location measured by the ratio of the distance from the centerline of the crack to the outer surface of the pipe over the pipe wall thickness (e{sub M}/t). Subsequent efforts develop, from a nonlinear curve-fitting procedure, a new set of equations to estimate the T-stress and K{sub I} values at three critical front locations of the axial elliptical cracks: the crack-front point O nearest to the outer surface of the pipe, the crack-front point I nearest to the inner surface of the pipe and the crack-front point M on the centerline of the axial crack. These equations combine a second-order polynomial with a power-law expression to predict the pronounced variations in the T-stress and K{sub I} values with respect to the geometric parameters. The coefficients of the new K{sub I} and T-stress equations either take a constant value or incorporate the linear variation with respect to the pipe wall thickness over the inner radius ratio, t/R{sub i}. The proposed equations demonstrate a close agreement with the finite element (FE) results, which indicate very strong

  8. Preoperative staging of esophageal carcinoma with multidetector CT and virtual endoscopy

    International Nuclear Information System (INIS)

    Onbas, Omer; Eroglu, Atilla; Kantarci, Mecit; Polat, Pinar; Alper, Fatih; Karaoglanoglu, Nurettin; Okur, Adnan

    2006-01-01

    Purpose: The aim of this study was to assess the accuracy of multidetector computed tomography (MDCT), including virtual endoscopy (VE) for detection, precise localization, preoperative evaluation and staging of esophageal cancer (EC) by comparison with surgical and histopathological findings. Materials and methods: Between September 2003 and April 2005, 44 patients with histologically proven EC underwent MDCT and VE. Among 44 patients, the findings were confirmed in 24 at surgery. The accuracy of three-dimensional MDCT for detection, localization, and staging of EC was determined, and compared with surgical finding and histopathology. Results: The overall accuracy of three-dimensional multidetector row CT for detection of EC was 100% (24/24). MDCT staging was correct in 20 patients (83.3%). The T parameter was correctly assessed in 22 (91.7%) cases (understaged in 1 and overstaged in 1). The N parameter was correctly evaluated in 20 (83.4%) patients (understaged in 2 and overstaged in 2). The overall accuracy of VE for the morphologic classification of EC was 81.5%. Conclusions: Three-dimensional MDCT, along with VE is a promising method for preoperative evaluation and staging of EC. Although accuracy in N staging remains low in comparison to PET, it provides a larger amount of diagnostic and staging information

  9. American Thyroid Association statement on preoperative imaging for thyroid cancer surgery.

    Science.gov (United States)

    Yeh, Michael W; Bauer, Andrew J; Bernet, Victor A; Ferris, Robert L; Loevner, Laurie A; Mandel, Susan J; Orloff, Lisa A; Randolph, Gregory W; Steward, David L

    2015-01-01

    The success of surgery for thyroid cancer hinges on thorough and accurate preoperative imaging, which enables complete clearance of the primary tumor and affected lymph node compartments. This working group was charged by the Surgical Affairs Committee of the American Thyroid Association to examine the available literature and to review the most appropriate imaging studies for the planning of initial and revision surgery for thyroid cancer. Ultrasound remains the most important imaging modality in the evaluation of thyroid cancer, and should be used routinely to assess both the primary tumor and all associated cervical lymph node basins preoperatively. Positive lymph nodes may be distinguished from normal nodes based upon size, shape, echogenicity, hypervascularity, loss of hilar architecture, and the presence of calcifications. Ultrasound-guided fine-needle aspiration of suspicious lymph nodes may be useful in guiding the extent of surgery. Cross-sectional imaging (computed tomography with contrast or magnetic resonance imaging) may be considered in select circumstances to better characterize tumor invasion and bulky, inferiorly located, or posteriorly located lymph nodes, or when ultrasound expertise is not available. The above recommendations are applicable to both initial and revision surgery. Functional imaging with positron emission tomography (PET) or PET-CT may be helpful in cases of recurrent cancer with positive tumor markers and negative anatomic imaging.

  10. Preoperative vs. postoperative radiation prophylaxis of heterotopic ossification: A rural community hospital's experience

    International Nuclear Information System (INIS)

    Kantorowitz, David A.; Muff, Nicholas S.

    1998-01-01

    Purpose: In vivo data employing a rat model, suggest equivalent suppression of ectopic bone formation by single-fraction irradiation given either pre (≤4 h)- or post (≤24 h)-surgery. Two subsequent randomized clinical trials, from tertiary academic centers with robust experience in heterotopic bone prophylaxis, have reached similar conclusions. To assess the transferability of the above data to the community setting we reviewed our rural community hospital experience with pre- and postoperative radiation prophylaxis. Methods and Materials: Between 11/90 and 6/96, 16 surgerized hips with high risk of heterotopic bone formation received 7.00-8.00 Gy in one fraction either preoperatively (≤4 h) (n = 9) or postoperatively (≤3 days for six hips; day 7 for one hip) (n = 7). Initial patients were routinely treated postoperatively. In late 1992, treatment preference was switched to preoperative irradiation in response to evolving data. The two groups were similar with respect to age, sex, nature of surgery, presurgical Brooker and Harris scores, and in U. of Rochester risk classification distribution. Irradiation was given via 4-20 MV photons through equally weighted AP:PA portals to the periacetabular tissues and proximal one third to one-half of the femoral component. Radiation dose, energy, portal, and blocking design were all similar for the two groups. Hip radiographs were obtained immediately postsurgery and at last follow-up: Delta grades (Brooker grade at follow-up--Brooker grade immediately postsurgery) were computed. Harris scale scores of hip function and movement were assigned via personal interviews and examinations performed prior to irradiation and at last follow-up. Results: All 16 hips are evaluable. Follow-up interval among the post-operative group (mean = 39.8 months; range 18.6-65.8) was significantly longer than among the preoperative group (mean = 20.4 months; range 8.6-41.3) (p < 0.02). The mean Delta grade among the postoperative and

  11. Dechanneling function for relativistic axially channeled electrons

    International Nuclear Information System (INIS)

    Muralev, V.A.; Telegin, V.I.

    1981-01-01

    Behaviour of the x(t) dechanneling function depending on the depth is theoretically studied. Theoretical consideration of x(t) for axial channeled relativistic electrons in anisotropic medium results in two-dimensional kinetic equation with mixed derivatives of the parabolic type. The kinetic equation in the approximation of the continuous Lindchard model for relativistic axial channeled electrons is numerically solved. The depth dependence of the x(t) dechanneling function is obtained [ru

  12. Singlet axial constant from QCD sum rules

    International Nuclear Information System (INIS)

    Belitskij, A.V.; Teryaev, O.V.

    1995-01-01

    We analyze the singlet axial form factor of the proton for small momentum transferred in the framework of QCD sum rules using the interpolating nucleon current which explicitly accounts for the gluonic degrees of freedom. As the result we come to the quantitative prediction of the singlet axial constant. It is shown that the bilocal power corrections play the most important role in the analysis. 21 refs., 3 figs

  13. 16. PRE-OPERATIVE BLADDER IRRIGATION

    African Journals Online (AJOL)

    Esem

    effectiveness of using preoperative bladder irrigation with 1% povidone iodine in reducing ... consenting patient who presented to the department of surgery for open ..... infections in a tertiary care center in south-western. Nigeria. International ...

  14. The impact of acute preoperative beta-blockade on perioperative ...

    African Journals Online (AJOL)

    To determine the impact of acute preoperative β-blockade on the incidence of perioperative cardiovascular morbidity and all- ... Our findings suggest that acute preoperative β-blockade is associated with an increased risk of perioperative cardiac ..... Shammash JB, Trost JC, Gold JM, Berlin JA, Golden MA, Kimmel SE.

  15. Implementation of Pre-Operative Checklist: An Effort to Reduce ...

    African Journals Online (AJOL)

    Implementation of Pre-Operative Checklist: An Effort to Reduce Delays in. Surgery and ... insight to develop a pre-operative checklist to ensure that patients were prepared for surgery and to minimize disruptions ... documentation audit was conducted in May 2014, showing 59% compliance in completing the checklist. Since.

  16. Axial clamp for nuclear reactor head penetration conoseal joints

    International Nuclear Information System (INIS)

    Hackley, T.A.

    1986-01-01

    A method for forming a sealed coupling between two bodies each body presenting an abutment surface, the bodies being arranged so that their respective abutment surfaces are axially adjacent one another and define a space therebetween in which a deformable gasket is disposed. An axial external force is applied to the bodies for compressing the abutment surfaces together against the gasket to form a seal between the bodies and the bodies are immobilized relative to one another while the external force is being applied to the bodies so that sufficient compression will be maintained by the abutment surfaces to preserve the integrity of the seal when the external axial force is withdrawn. The external axial force is then withdrawn, leaving the two bodies coupled together via the seal. (author)

  17. Low dose preoperative radiotherapy for carcinoma of the oesophagus

    International Nuclear Information System (INIS)

    Arnott, S.J.; Duncan, W.; Kerr, G.R.; Jack, W.J.L.; Mackillop, W.J.; Walbaum, P.R.; Cameron, E.

    1992-01-01

    Patients (176) with potentially operable squamous cell carcinoma or adenocarcinoma of middle or lower thirds of oesophagus were randomly assigned to preoperative radiotherapy or surgery alone. Patients assigned to the radiotherapy arm received 20 Gy in 10 treatments over 2 weeks, using parallel opposed 4 MV beams. The preoperative radiotherapy was not associated with any significant acute morbidity or any increase in operative complications. The median survival of the overall group of 176 patients was 8 moths, and the 5-year survival was 13%. There was no significant difference in the survival of the 90 patients who received preoperative radiotherapy and the 86 who were managed by surgery alone. Proportional hazards analysis identified lymph node involvement, high tumor grade and male sex as significant adverse prognostic features, but the treatment option assigned had no prognostic significance. It was concluded that low dose preoperative radiotherapy offered no advantage over surgery alone. (author). 9 refs.; 3 figs.; 6 tabs

  18. Preoperative cryotherapy use in anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Koyonos, Loukas; Owsley, Kevin; Vollmer, Emily; Limpisvasti, Orr; Gambardella, Ralph

    2014-12-01

    Unrelieved postoperative pain may impair rehabilitation, compromise functional outcomes, and lead to patient dissatisfaction. Preemptive multimodal analgesic techniques may improve outcomes after surgery. We hypothesized that patients using preoperative cryotherapy plus a standardized postoperative treatment plan will have lower pain scores and require less pain medication compared with patients receiving a standardized postoperative treatment plan alone after arthroscopically assisted anterior cruciate ligament reconstruction (ACLR). A total of 53 consecutive patients undergoing arthroscopically assisted ACLR performed by one of seven surgeons were randomly assigned to one of two groups. Group 1 received no preoperative cryotherapy and group 2 received 30 to 90 minutes of preoperative cryotherapy to the operative leg using a commercial noncompressive cryotherapy unit. Visual analog scale pain scores and narcotic use were recorded for the first 4 days postoperatively. Total hours of cold therapy and continuous passive motion (CPM) use and highest degree of flexion achieved were recorded as well. Group 1 consisted of 26 patients (15 allograft Achilles tendon and 11 autograft bone patellar tendon bone [BPTB]), and group 2 consisted of 27 patients (16 allograft Achilles tendon and 11 autograft BPTB). Group 2 patients reported less pain (average 1.3 units, p cryotherapy, hours of CPM use, or maximum knee flexion achieved. Complications did not occur in either group. This is the first report we are aware of showing the postoperative effects of preoperative cryotherapy. Our results support the safety and efficacy of preoperative cryotherapy in a multimodal pain regimen for patients undergoing ACL reconstruction. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  19. Axial Dispersion during Hanford Saltcake Washing

    International Nuclear Information System (INIS)

    Josephson, Gary B.; Geeting, John GH; Lessor, Delbert L.; Barton, William B.

    2006-01-01

    Clean up of Hanford salt cake wastes begins with dissolution retrieval of the sodium rich salts that make up the dominant majority of mass in the tanks. Water moving through the porous salt cake dissolves the soluble components and also displaces the soluble radionuclides (e.g. 137Cs and 99TcO4- ). The separation that occurs from this displacement, known as Selective dissolution, is an important component in Hanford?s pretreatment of low activity wastes for subsequent Supplemental treatment. This paper describes lab scale testing conducted to evaluate Selective dissolution of cesium from non-radioactive Hanford tank 241-S-112 salt cake simulant containing the primary chemicals found the actual tank. An modified axial dispersion model with increasing axial dispersion was developed to predict cesium removal. The model recognizes that water dissolves the salt cake during washing, which causes an increase in the axial dispersion during the wash. This model was subsequently compared with on-line cesium measurements from the retrieval of tank 241-S-112. The model had remarkably good agreement with both the lab scale and full scale data

  20. The Effect of Mild Preoperative Renal Impairment on Early ...

    African Journals Online (AJOL)

    Introduction: Severe preoperative renal impairment (RI) is often included in score systems used to predict outcome after open cardiac surgery. The purpose of this study was to investigate the impact of mild preoperative RI on the early postoperative mortality after open heart surgery. Methods: We retrospectively collected ...

  1. Coronary Heart Disease Preoperative Gesture Interactive Diagnostic System Based on Augmented Reality.

    Science.gov (United States)

    Zou, Yi-Bo; Chen, Yi-Min; Gao, Ming-Ke; Liu, Quan; Jiang, Si-Yu; Lu, Jia-Hui; Huang, Chen; Li, Ze-Yu; Zhang, Dian-Hua

    2017-08-01

    Coronary heart disease preoperative diagnosis plays an important role in the treatment of vascular interventional surgery. Actually, most doctors are used to diagnosing the position of the vascular stenosis and then empirically estimating vascular stenosis by selective coronary angiography images instead of using mouse, keyboard and computer during preoperative diagnosis. The invasive diagnostic modality is short of intuitive and natural interaction and the results are not accurate enough. Aiming at above problems, the coronary heart disease preoperative gesture interactive diagnostic system based on Augmented Reality is proposed. The system uses Leap Motion Controller to capture hand gesture video sequences and extract the features which that are the position and orientation vector of the gesture motion trajectory and the change of the hand shape. The training planet is determined by K-means algorithm and then the effect of gesture training is improved by multi-features and multi-observation sequences for gesture training. The reusability of gesture is improved by establishing the state transition model. The algorithm efficiency is improved by gesture prejudgment which is used by threshold discriminating before recognition. The integrity of the trajectory is preserved and the gesture motion space is extended by employing space rotation transformation of gesture manipulation plane. Ultimately, the gesture recognition based on SRT-HMM is realized. The diagnosis and measurement of the vascular stenosis are intuitively and naturally realized by operating and measuring the coronary artery model with augmented reality and gesture interaction techniques. All of the gesture recognition experiments show the distinguish ability and generalization ability of the algorithm and gesture interaction experiments prove the availability and reliability of the system.

  2. Effects of preoperative irradiation on primary tracheal anastomosis

    International Nuclear Information System (INIS)

    Tsubota, N.; Simpson, W.J.; Van Nostrand, A.W.P.; Pearson, F.G.

    1975-01-01

    Preoperative radiotherapy was used in the management of selected patients with cancer of the lung or trachea who might subsequently require segmental resection of bronchus or trachea and reconstruction by primary anastomosis. This study was designed to determine the effects of varying dosages of preoperative irradiation on anastomotic healing. Two rings were resected from the cervical trachea of 20 dogs following irradiation with varying doses of cesium. There were no important adverse effects on healing of the trachea or adjacent organs in dogs receiving up to 3,500 rads. All dogs receiving a higher dose than this developed some anastomotic stenosis, which was severe in 6 of 8 animals. Similar adverse effects were observed in 2 patients managed by preoperative radiotherapy (4,000 rads in three weeks) and tracheal resection with primary anastomosis

  3. Effects of preoperative irradiation on primary tracheal anastomosis

    Energy Technology Data Exchange (ETDEWEB)

    Tsubota, N.; Simpson, W.J.; Van Nostrand, A.W.P.; Pearson, F.G.

    1975-08-01

    Preoperative radiotherapy was used in the management of selected patients with cancer of the lung or trachea who might subsequently require segmental resection of bronchus or trachea and reconstruction by primary anastomosis. This study was designed to determine the effects of varying dosages of preoperative irradiation on anastomotic healing. Two rings were resected from the cervical trachea of 20 dogs following irradiation with varying doses of cesium. There were no important adverse effects on healing of the trachea or adjacent organs in dogs receiving up to 3,500 rads. All dogs receiving a higher dose than this developed some anastomotic stenosis, which was severe in 6 of 8 animals. Similar adverse effects were observed in 2 patients managed by preoperative radiotherapy (4,000 rads in three weeks) and tracheal resection with primary anastomosis.

  4. Damped gyroscopic effects and axial-flexural-torsional coupling using spinning finite elements for wind-turbine blades characterization

    Science.gov (United States)

    Velazquez, Antonio; Swartz, R. Andrew

    2013-04-01

    Renewable energy sources like wind are important technologies, useful to alleviate for the current fossil-fuel crisis. Capturing wind energy in a more efficient way has resulted in the emergence of more sophisticated designs of wind turbines, particularly Horizontal-Axis Wind Turbines (HAWTs). To promote efficiency, traditional finite element methods have been widely used to characterize the aerodynamics of these types of multi-body systems and improve their design. Given their aeroelastic behavior, tapered-swept blades offer the potential to optimize energy capture and decrease fatigue loads. Nevertheless, modeling special complex geometries requires huge computational efforts necessitating tradeoffs between faster computation times at lower cost, and reliability and numerical accuracy. Indeed, the computational cost and the numerical effort invested, using traditional FE methods, to reproduce dependable aerodynamics of these complex-shape beams are sometimes prohibitive. A condensed Spinning Finite Element (SFE) method scheme is presented in this study aimed to alleviate this issue by means of modeling wind-turbine rotor blades properly with tapered-swept cross-section variations of arbitrary order via Lagrangian equations. Axial-flexural-torsional coupling is carried out on axial deformation, torsion, in-plane bending and out-of-plane bending using super-convergent elements. In this study, special attention is paid for the case of damped yaw effects, expressed within the described skew-symmetric damped gyroscopic matrix. Dynamics of the model are analyzed by achieving modal analysis with complex-number eigen-frequencies. By means of mass, damped gyroscopic, and stiffness (axial-flexural-torsional coupling) matrix condensation (order reduction), numerical analysis is carried out for several prototypes with different tapered, swept, and curved variation intensities, and for a practical range of spinning velocities at different rotation angles. A convergence study

  5. Vertebral column decancellation in Pott's deformity: use of Surgimap Spine for preoperative surgical planning, retrospective review of 18 patients.

    Science.gov (United States)

    Hu, Wenhao; Zhang, Xuesong; Yu, Jiayi; Hu, Fanqi; Zhang, Hao; Wang, Yan

    2018-01-15

    In the late stage of Spinal tuberculosis, the bony destruction and vertebral collapse often leads to significant kyphosis, presenting clinically as a painful gibbus deformity, with increased instability, vertebral body translations and increased risk of neurologic involvement. Vertebral column decancellation is thought to be suitable for most patients with severe rigid kyphosis. Surgimap Spine, could offer a pragmatic graphical method for the surgical planning of osteotomies. The aim of this study was to evaluate the efficacy of Vertebral column decancellation planned preoperatively with the computer software-assistance in the patients with Pott's kyphosis. Between May 2012 and May 2015, 18 patients with Pott's kyphosis underwent the Vertebral column decancellation using Surgimap Spine for preoperative surgical planning. Preoperative and postoperative Konstam's angle, sagittal vertical angle, lumbar lordosis, thoracic kyphosis, pelvic tilt and pelvic incidence were measured. Visual analog scale and American Spinal Injury Association were documented. The Konstam's angles decreased from 88.1° (range, 70-105°) preoperatively to 18.5° (range, 7-31°) (P column decancellation is an effective treatment option for severe Pott's kyphosis. The surgical planning software Surgimap Spine can be a reliable and helpful tool that provides a simplified method to evaluate and analyze the spino-pelvic parameters and simulate the osteotomy procedure. According to individual character, the appropriate surgery strategy should be selected.

  6. [Myopia: frequency of lattice degeneration and axial length].

    Science.gov (United States)

    Martín Sánchez, M D; Roldán Pallarés, M

    2001-05-01

    To evaluate the relationship between lattice retinal degeneration and axial length of the eye in different grades of myopia. A sample of 200 eyes from 124 myopic patients was collected by chance. The average age was 34.8 years (20-50 years) and the myopia was between 0.5 and 20 diopters (D). The eyes were grouped according to the degree of refraction defect, the mean axial length of each group (Scan A) and the frequency of lattice retinal degeneration and the relationship between these variables was studied. The possible influence of age on our results was also considered. For the statistical analysis, the SAS 6.07 program with the variance analysis for quantitative variables, and chi(2) test for qualitative variables with a 5% significance were used. A multivariable linear regression model was also adjusted. The highest frequency of lattice retinal degeneration occurred in those myopia patients having more than 15 D, and also in the group of myopia patients between 3 and 6 D, but this did not show statistical significance when compared with the other myopic groups. If the axial length is assessed, a greater frequency of lattice retinal degeneration is also found when the axial length is 25-27 mm and 29-30 mm, which correspond, respectively, to myopias between 3-10 D and more than 15 D. When the multivariable linear regression model was adjusted, the axial length showed the existence of lattice retinal degeneration (beta 0.41 mm; p=0.08) adjusted by the number of diopters (beta 0.38 mm; plattice retinal degeneration was found for myopias with axial eye length between 29-30 mm (more than 15 D), and 25-27 mm (between 3-10 D).

  7. Effect of Preoperative Mastoid Ventilation on Tympanoplasty Success

    Directory of Open Access Journals (Sweden)

    Mehmet Metin

    2014-01-01

    Full Text Available Purpose. This study was conducted with the aim of investigating the relationship between mastoid air cell volumes and graft success after tympanoplasty. Material and Methods. This study was performed retrospectively with patients undergoing type I tympanoplasty and antrostomy. A total of 57 patients (20–35.09% female and 37–64.91% male with a mean age of 29.69±SD (range 12–56 years were included in the study. The patients were invited for a control at the 1st, 3rd, and 12th months, and otoscopic examinations and audiometric tests were performed. The temporal bone computed tomography images were screened with the 4800 Dpi optic resolution scanner and transferred to the computer environment in JPG format in order to calculate the mastoid air cell volume, and the volumes were calculated using the Autocad 2007 program. Results. Although, the graft success was determined to be better in the well-ventilated group, no significant difference could be found between the groups in terms of graft success at the 1st, 3rd, and 12th months (P>0.05. No statistically significant difference could be found between the three groups in terms of the preoperative and postoperative hearing gains (P>0.05.

  8. Effect of preoperative mastoid ventilation on tympanoplasty success.

    Science.gov (United States)

    Metin, Mehmet; Kaptan, Zeynep Kizilkaya; Dogan, Sedat; Yazici, Hasmet; Bayraktar, Cem; Gocmen, Hakan; Samim, Etem Erdal

    2014-01-01

    Purpose. This study was conducted with the aim of investigating the relationship between mastoid air cell volumes and graft success after tympanoplasty. Material and Methods. This study was performed retrospectively with patients undergoing type I tympanoplasty and antrostomy. A total of 57 patients (20-35.09% female and 37-64.91% male) with a mean age of 29.69 ± SD (range 12-56 years) were included in the study. The patients were invited for a control at the 1st, 3rd, and 12th months, and otoscopic examinations and audiometric tests were performed. The temporal bone computed tomography images were screened with the 4800 Dpi optic resolution scanner and transferred to the computer environment in JPG format in order to calculate the mastoid air cell volume, and the volumes were calculated using the Autocad 2007 program. Results. Although, the graft success was determined to be better in the well-ventilated group, no significant difference could be found between the groups in terms of graft success at the 1st, 3rd, and 12th months (P > 0.05). No statistically significant difference could be found between the three groups in terms of the preoperative and postoperative hearing gains (P > 0.05).

  9. Preoperative depression symptom severity and its impact on adherence to preoperative beta-blocker therapy.

    Science.gov (United States)

    Schonberger, Robert B; Feinleib, Jessica; Holt, Natalie; Dai, Feng; Brandt, Cynthia; Burg, Matthew M

    2014-12-01

    To test the association among depression symptoms, distressed personality type, and preoperative beta-blocker nonadherence and to estimate the prevalence of untreated major depression in this population. Prospective observational study. A veterans hospital. One hundred twenty patients on outpatient beta-blocker therapy presenting for surgery. The Patient Health Questionnaire (PHQ)-9, the D-Scale-14 (DS14), and Modified Morisky Scale (MMS) questionnaires. Of 99 participants who presented for surgery, the incidence of preoperative nonadherence was 14.1% (95% confidence interval 7%-21%), consistent with prior research. Nonadherence was 9.5% among those with no depression, 27.8% among those with mild depression, and 28.6% among those with moderate-to-severe depression (Cochran-Armitage test for trend p = 0.03). Distressed personality type was found in 35% of the cohort (95% confidence interval 26-45%) and was not associated with beta-blocker nonadherence (Fisher's exact test, p = 0.24). Among participants with symptoms of major depressive disorder (n = 25, 25.3%), more than half (n = 14, 56%) had no indication of depression listed at their most recent primary care visit. Patients with symptoms of depression on chronic beta-blocker therapy are susceptible to medication nonadherence on the day of surgery. Most surgical patients with symptoms of major depression lack a diagnosis of depression. Preoperative depression screening may thus (1) identify a population at increased risk of beta-blocker withdrawal, and (2) identify patients who may benefit from anesthesiologist-initiated referral for this treatable condition. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Investigation of angular and axial smoothing of PET data

    International Nuclear Information System (INIS)

    Daube-Witherspoon, M.E.; Carson, R.E.

    1996-01-01

    Radial filtering of emission and transmission data is routinely performed in PET during reconstruction in order to reduce image noise. Angular smoothing is not typically done, due to the introduction of a non-uniform resolution loss; axial filtering is also not usually performed on data acquired in 2D mode. The goal of this paper was to assess the effects of angular and axial smoothing on noise and resolution. Angular and axial smoothing was incorporated into the reconstruction process on the Scanditronix PC2048-15B brain PET scanner. In-plane spatial resolution and noise reduction were measured for different amounts of radial and angular smoothing. For radial positions away from the center of the scanner, noise reduction and degraded tangential resolution with no loss of radial resolution were seen. Near the center, no resolution loss was observed, but there was also no reduction in noise for angular filters up to a 7 degrees FWHM. These results can be understood by considering the combined effects of smoothing projections across rows (angles) and then summing (backprojecting). Thus, angular smoothing is not optimal due to its anisotropic noise reduction and resolution degradation properties. However, uniform noise reduction comparable to that seen with radial filtering can be achieved with axial smoothing of transmission data. The axial results suggest that combined radial and axial transmission smoothing could lead to improved noise characteristics with more isotropic resolution degradation

  11. Axial clamp for nuclear reactor head penetration conoseal joints

    International Nuclear Information System (INIS)

    Hackley, T.A.

    1987-01-01

    A method is described for forming a sealed coupling between two bodies, each body presenting an annular abutment surface. The respective bodies are arranged so that their respective annular abutment surfaces are axially adjacent one another, defining a space therebetween, wherein a deformable gasket is disposed within the space. The method comprises: providing one of the bodies with an annular projection; providing the other body with threads for receiving an annular locknut which can be tightened to bear against the annular projection of the one body; applying an external axial forced to the bodies for compressing the abutment surfaces together against the gasket to form a seal between the bodies; immobilizing the bodies relative to one another while the external force is being applied to the bodies by hand-tightening an annular locknut via the threads of the other body until the locknut abuts the annular projection of the one body, substantially preventing relative axial movement between the bodies when the external axial force is withdrawn; and withdrawing the external axial force applied to the bodies, leaving the two bodies coupled together via the seal

  12. National variation in preoperative imaging, carotid duplex ultrasound criteria, and threshold for surgery for asymptomatic carotid artery stenosis.

    Science.gov (United States)

    Arous, Edward J; Simons, Jessica P; Flahive, Julie M; Beck, Adam W; Stone, David H; Hoel, Andrew W; Messina, Louis M; Schanzer, Andres

    2015-10-01

    Carotid endarterectomy (CEA) for asymptomatic carotid artery stenosis is among the most common procedures performed in the United States. However, consensus is lacking regarding optimal preoperative imaging, carotid duplex ultrasound criteria, and ultimately, the threshold for surgery. We sought to characterize national variation in preoperative imaging, carotid duplex ultrasound criteria, and threshold for surgery for asymptomatic CEA. The Society for Vascular Surgery Vascular Quality Initiative (VQI) database was used to identify all CEA procedures performed for asymptomatic carotid artery stenosis between 2003 and 2014. VQI currently captures 100% of CEA procedures performed at >300 centers by >2000 physicians nationwide. Three analyses were performed to quantify the variation in (1) preoperative imaging, (2) carotid duplex ultrasound criteria, and (3) threshold for surgery. Of 35,695 CEA procedures in 33,488 patients, the study cohort was limited to 19,610 CEA procedures (55%) performed for asymptomatic disease. The preoperative imaging modality used before CEA varied widely, with 57% of patients receiving a single preoperative imaging study (duplex ultrasound imaging, 46%; computed tomography angiography, 7.5%; magnetic resonance angiography, 2.0%; cerebral angiography, 1.3%) and 43% of patients receiving multiple preoperative imaging studies. Of the 16,452 asymptomatic patients (89%) who underwent preoperative duplex ultrasound imaging, there was significant variability between centers in the degree of stenosis (50%-69%, 70%-79%, 80%-99%) designated for a given peak systolic velocity, end diastolic velocity, and internal carotid artery-to-common carotid artery ratio. Although 68% of CEA procedures in asymptomatic patients were performed for an 80% to 99% stenosis, 26% were performed for a 70% to 79% stenosis, and 4.1% were performed for a 50% to 69% stenosis. At the surgeon level, the range in the percentage of CEA procedures performed for a duplex ultrasound

  13. Three-dimensional magnetotelluric axial anisotropic forward modeling and inversion

    Science.gov (United States)

    Cao, Hui; Wang, Kunpeng; Wang, Tao; Hua, Boguang

    2018-06-01

    Magnetotelluric (MT) data has been widely used to image underground electrical structural. However, when the significant axial resistivity anisotropy presents, how this influences three-dimensional MT data has not been resolved clearly yet. We here propose a scheme for three-dimensional modeling of MT data in presence of axial anisotropic resistivity, where the electromagnetic fields are decomposed into primary and secondary components. A 3D staggered-grid finite difference method is then used to resolve the resulting 3D governing equations. Numerical tests have completed to validate the correctness and accuracy of the present algorithm. A limited-memory Broyden-Fletcher-Goldfarb-Shanno method is then utilized to realize the 3D MT axial anisotropic inversion. The testing results show that, compared to the results of isotropic resistivity inversion, taking account the axial anisotropy can much improve the inverted results.

  14. Ball Screw Actuator Including an Axial Soft Stop

    Science.gov (United States)

    Wingett, Paul T. (Inventor); Forrest, Steven Talbert (Inventor); Abel, Steve (Inventor); Woessner, George (Inventor); Hanlon, Casey (Inventor)

    2016-01-01

    An actuator includes an actuator housing, a ball screw, and an axial soft stop assembly. The ball screw extends through the actuator housing and has a first end and a second end. The ball screw is coupled to receive a drive force and is configured, upon receipt of the drive force, to selectively move in a retract direction and an extend direction. The axial soft stop assembly is disposed within the actuator housing. The axial soft stop assembly is configured to be selectively engaged by the ball screw and, upon being engaged thereby, to translate, with compliance, a predetermined distance in the extend direction, and to prevent further movement of the ball screw upon translating the predetermined distance.

  15. GPS Modeling and Analysis. Summary of Research: GPS Satellite Axial Ratio Predictions

    Science.gov (United States)

    Axelrad, Penina; Reeh, Lisa

    2002-01-01

    This report outlines the algorithms developed at the Colorado Center for Astrodynamics Research to model yaw and predict the axial ratio as measured from a ground station. The algorithms are implemented in a collection of Matlab functions and scripts that read certain user input, such as ground station coordinates, the UTC time, and the desired GPS (Global Positioning System) satellites, and compute the above-mentioned parameters. The position information for the GPS satellites is obtained from Yuma almanac files corresponding to the prescribed date. The results are displayed graphically through time histories and azimuth-elevation plots.

  16. Axial Vircator for Electronic Warfare Applications

    Directory of Open Access Journals (Sweden)

    L. Drazan

    2009-12-01

    Full Text Available This paper deals with a high power microwave generator with virtual cathode – vircator in axial release for electronic warfare applications. The classification of directed energy weapons microwave (DEWM is introduced together with basic block diagrams of a particular class of DEWM. In the paper, methods for designing vircator pulsed power supply, axial vircator structure, measurement methods and experimental results are presented. The vircator in electromagnetic ammunition is powered by magneto-cumulative generator and in weapons for defense of objects (WDO, it is powered by Marx generator. The possible applications of a vircator in the DEWM area are discussed.

  17. Generalized dynamic model and control of ambiguous mono axial vehicle robot

    Directory of Open Access Journals (Sweden)

    Frantisek Duchon

    2016-09-01

    Full Text Available This article deals with the novel concept of ambiguous mono axial vehicle robot. Such robot is a combination of Segway and dicycle, which utilizes the advantages of each chassis. The advantage of dicycle is lower energy consumption during the movement and the higher safety of carried payload. The movable platform inside the ambiguous mono axial vehicle allows using the various sensors or devices. This will change the ambiguous mono axial vehicle to the Segway type robot. Both these modes are necessary to control in the stable mode to ensure the safety of the ambiguous mono axial vehicle’s movement. The main contents of the article contain description of generalized dynamic model of ambiguous mono axial vehicle and related control of ambiguous mono axial vehicle. The proposal is unique in that the same controller is used for both modes. Several simulations verify proposed control schemes and identified parameters. Moreover, the dicycle type of platform has never been used in robotics and that is another novelty.

  18. FFTF preoperational survey. Program report

    International Nuclear Information System (INIS)

    Twitty, B.L.; Bicehouse, H.J.

    1980-12-01

    The FFTF will become operational with criticality early in 1980. This facility is composed of the test reactor, fuel examination cells, expended fuel storage systems and fuel handling systems. The reactor and storage systems are sodium-cooled with the heat load dumped to the ambient air through heat exchangers. In order to assure that the operation of the FFTF has minimal impact on the environment, a monitoring program has been established. Prior to operation of a new facility, a preoperational environmental survey is required. It is the purpose of this report to briefly describe the environmental survey program and to provide the background data obtained during the preoperational phase of the survey program. Nine stations in the program of particular importance to FFTF are discussed in detail with results of monitoring given. No unexplained trends were noted

  19. Molecular design for nonpolar chiral-axial quadratic nonlinear optics

    Science.gov (United States)

    Wiggers, Gregory A.

    In this thesis the hyperpolarizability of various multi-dimensional molecules is studied theoretically/computationally, with particular focus on the second-rank Kleinman-disallowed (KD) component of the hyperpolarizability. This component, which transforms as a second-rank traceless symmetric tensor, could be utilized in certain chiral-axial molecular alignment schemes to produce a bulk response. Nonpolar chiral-axial systems have been proposed in contrast to polar media, which utilize the vector component of the molecular hyperpolarizability and require parallel alignment of the molecular dipoles. Such parallel alignment of dipoles must be "frozen in" in order to overcome the natural tendency for dipoles to align anti-parallel. This limits the density of chromophores that can be loaded into a polar material. Nonpolar materials do not have such limits in theory. The two geometric classes of molecules that can most easily be incorporated into nonpolar chiral-uniaxial materials are propeller-shaped (C3 or D3 symmetry) and Λ-shaped (C2v symmetry). This work describes efforts to design molecules within these classes that would be suitable for bulk NLO materials. The sum-over-states (SOS) expression is used to model the molecular hyperpolarizability, and quantum chemical calculations, along with linear absorption data (when available) provide the necessary parameters to evaluate truncated forms of the SOS expression. A host of chemical and geometric modifications will be considered in order to elucidate important structure/function relationships. Also, the SOS model will be tested in some cases when experimental measurements (via Kleinman-disallowed hyper-Rayleigh scattering) are available. While a majority of this work focuses on multi-dimensional molecules, a small section deals with the question of optimizing the hyperpolarizability of a one-dimensional system. It is suggested that the recently-proposed idea of "modulated conjugation" as a means for improving

  20. Interobserver and Intraobserver Reliability of Three-Dimensional Preoperative Planning Software in Total Hip Arthroplasty.

    Science.gov (United States)

    Wako, Yasushi; Nakamura, Junichi; Miura, Michiaki; Kawarai, Yuya; Sugano, Masahiko; Nawata, Kento

    2018-02-01

    The purpose of this study is to clarify interobserver and intraobserver reliabilities of the three-dimensional (3D) templating of total hip arthroplasty (THA). We selected preoperative computed tomography from 60 hips in 46 patients (14 men and 32 women) who underwent primary THA. To evaluate interobserver and intraobserver reliability, 6 orthopedic surgeons performed 3D templating twice over a 4-week interval. We investigated intraclass correlation coefficients (ICCs) and percent agreement of component size and alignment, comparing morphological differences in the hip. Reproducibility was also compared between groups with osteoarthritis (OA) and those with osteonecrosis (ON). The interobserver reliabilities for mean cup size and stem size were excellent, with ICC = 0.907 and 0.944, respectively. The value was significantly higher in the ON group than in the OA group. In the OA group, the reliability of cup size and alignment decreased in hips with severe subluxation. Percent agreement of stem size was significantly different between the shapes of femoral canal. For intraobserver reliability, the mean ICC of cup size was 0.965 overall, while the value in the ON group was significantly higher than in the OA group. The mean ICC of stem size was 0.972 overall. Computed tomography-based 3D templating showed excellent reliability for component size and alignment in THA. Deformity of the affected joint influenced the reliability of preoperative planning. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Measurement for cobalt target activity and its axial distribution

    International Nuclear Information System (INIS)

    Li Xingyuan; Chen Zigen.

    1985-01-01

    Cobalt target activity and its axial distribution are measured in process of producing radioactive isotopes 60 Co by irradiation in HFETR. Cobalt target activity is obtained with measured data at 3.60 m and 4.60 m, relative axial distribution of cobalt target activity is obtained with one at 30 cm, and axial distribution of cobalt target activity(or specific activity) is obtained with both of data. The difference between this specific activity and measured result for 60 Co teletherapy sources in the end is less than +- 5%

  2. The spin of the proton and the axial anomaly

    International Nuclear Information System (INIS)

    Hatsuda, T.; Zahed, I.

    1989-01-01

    We show that a consistent treatment of the abelian axial anomaly in a two-phase model of the proton yields a flavor singlet axial current that is saturated by the anomaly at Q 2 =0 in the chiral limit. This result suggests that at Q 2 =0 the matrix element of the flavor singlet axial current in a polarized proton state is small while the proton spin is still one-half. Modulo the QCD evolution equation, this result is in fair agreement with the recent EMC data. (orig.)

  3. RAP-3A Computer code for thermal and hydraulic calculations in steady state conditions for fuel element clusters

    International Nuclear Information System (INIS)

    Popescu, C.; Biro, L.; Iftode, I.; Turcu, I.

    1975-10-01

    The RAP-3A computer code is designed for calculating the main steady state thermo-hydraulic parameters of multirod fuel clusters with liquid metal cooling. The programme provides a double accuracy computation of temperatures and axial enthalpy distributions of pressure losses and axial heat flux distributions in fuel clusters before boiling conditions occur. Physical and mathematical models as well as a sample problem are presented. The code is written in FORTRAN-4 language and is running on a IBM-370/135 computer

  4. Test Setup for Axially Loaded Piles in Sand

    DEFF Research Database (Denmark)

    Thomassen, Kristina

    The test setup for testing axially static and cyclic loaded piles in sand is described in the following. The purpose for the tests is to examine the tensile capacity of axially loaded piles in dense fully saturated sand. The pile dimensions are chosen to resemble full scale dimension of piles used...... in offshore pile foundations today....

  5. An axial calculation method for accurate two-dimensional PWR core simulation

    International Nuclear Information System (INIS)

    Grimm, P.

    1985-02-01

    An axial calculation method, which improves the agreement of the multiplication factors determined by two- and three-dimensional PWR neutronic calculations, is presented. The axial buckling is determined at each time point so as to reproduce the increase of the leakage due to the flattening of the axial power distribution and the effect of the axial variation of the group constants of the fuel on the reactivity is taken into account. The results of a test example show that the differences of k-eff and cycle length between two- and three-dimensional calculations, which are unsatisfactorily large if a constant buckling is used, become negligible if the results of the axial calculation are used in the two-dimensional core simulation. (Auth.)

  6. Cross-sectional imaging with rotational panoramic X-ray machine for preoperative assessment of dental implant site. Comparisons of imaging properties with conventional film tomography and computed tomography

    International Nuclear Information System (INIS)

    Makihara, Masahiro; Nishikawa, Keiichi; Kuroyanagi, Kinya

    2001-01-01

    To clarify the validity of cross-sectional imaging with rotational panoramic x-ray machine for preoperative assessment of the dental implant site, the imaging properties were compared with those of spiral tomography and multi-planer reconstruction (MPR) manipulation of x-ray computed tomography. Cross-sectional imaging of the maxilla and mandible of an edentulous dry skull was performed by each technique at an image layer thickness of 1 mm. Steel spheres were used to identify cross-sectional planes and measure distance. Six oral radiologists scored the image clarity of structures with 5-grade rating scales and measured the distance between images of 2 steel spheres. Each measured distance was divided by the magnification factor. The actual distance was also measured on the skull. The score and the distance were statistically compared. The Spearman's rank correlation coefficients for the score and the absolute values of the difference in distances measured by different observers were calculated as test units to compare inter-observer agreements statistically. The same observation and measurement were repeated to compare intra-observer agreement. Image clarity of the linear tomography available with a panoramic machine was comparable to spiral tomography and superior to MPR, except for the cortical bone on the lingual side. The inter- and intra-observer agreements were comparable. The accuracy for measurement of distance, the inter- and intra-observer agreements were also comparable to the spiral tomography and superior to those of MPR. Therefore, it is concluded that cross-sectional imaging with a rotational panoramic x-ray machine is useful for preoperative assessment of the dental implant site. (author)

  7. Computer Programme for the Dynamic Analysis of Tall Regular ...

    African Journals Online (AJOL)

    The traditional method of dynamic analysis of tall rigid frames assumes the shear frame model. Models that allow joint rotations with/without the inclusion of the column axial loads give improved results but pose much more computational difficulty. In this work a computer program Natfrequency that determines the dynamic ...

  8. Ultrasound and multidetector computed tomography of mandibular ...

    African Journals Online (AJOL)

    Because of local invasivity and high metastatic potential, preoperative imaging evaluation of mandibular region and tumoral staging is essential along with biopsy sampling. The present manuscript describes the ultrasound and computed tomographic imaging findings of mandibular gland adenocarcinoma in two dogs and ...

  9. Multidetector computed tomography with triple-bolus contrast medium administration protocol for preoperative anatomical and functional assessment of potential living renal donors

    International Nuclear Information System (INIS)

    Knox, Matthew K.; Rivers-Bowerman, Michael D.; Bardgett, Harry P.; Cowan, Nigel C.

    2010-01-01

    To evaluate multidetector computed tomography (MDCT) with a triple-bolus contrast administration protocol for preoperative anatomical and functional assessment of living renal donors. Fifty-five potential living renal donors underwent MDCT of which 27 proceeded to donor nephrectomy. A triple-bolus contrast administration protocol was used for simultaneous acquisition of arterial, nephrographic, and excretory phases. MDCT images were independently reviewed in random order by two radiologists blinded to surgical anatomy findings. Diagnostic accuracy for anatomical variants was quantified by sensitivity and specificity. Differential renal function (DRF) was derived from MDCT for 54 patients and compared with technetium-99 m dimercaptosuccinic acid renography (Tc-99 m DMSA). All triple-bolus MDCT examinations were technically adequate. Accessory renal arteries and veins were identified at surgery in 33% (n = 9/27) and 22% (n = 6/27) of donor kidneys. The mean difference between MDCT-derived DRF and DMSA was 0.8% (95% CI 0.1-1.6) with 95% limits of agreement of -4.6% (95% CI -3.3 to -5.9) to 6.3% (95% CI 5.0-7.6). MDCT delivered a mean (SD, range) radiation dose of 9.5 (3.6, 3.6-17.3) mSv. MDCT with a triple-bolus contrast administration provides accurate anatomical and functional evaluation of living renal donors. (orig.)

  10. Multidetector computed tomography with triple-bolus contrast medium administration protocol for preoperative anatomical and functional assessment of potential living renal donors

    Energy Technology Data Exchange (ETDEWEB)

    Knox, Matthew K. [University of Calgary, Faculty of Medicine, UME Office, Health Sciences Centre, Calgary, Alberta (Canada); Rivers-Bowerman, Michael D. [University of British Columbia, Faculty of Medicine, MD Undergraduate Program, Diamond Health Care Centre, Vancouver, British Columbia (Canada); Bardgett, Harry P. [Bradford Teaching Hospitals, Department of Radiology, Bradford (United Kingdom); Cowan, Nigel C. [The Churchill Hospital, Department of Radiology, Oxford (United Kingdom)

    2010-11-15

    To evaluate multidetector computed tomography (MDCT) with a triple-bolus contrast administration protocol for preoperative anatomical and functional assessment of living renal donors. Fifty-five potential living renal donors underwent MDCT of which 27 proceeded to donor nephrectomy. A triple-bolus contrast administration protocol was used for simultaneous acquisition of arterial, nephrographic, and excretory phases. MDCT images were independently reviewed in random order by two radiologists blinded to surgical anatomy findings. Diagnostic accuracy for anatomical variants was quantified by sensitivity and specificity. Differential renal function (DRF) was derived from MDCT for 54 patients and compared with technetium-99 m dimercaptosuccinic acid renography (Tc-99 m DMSA). All triple-bolus MDCT examinations were technically adequate. Accessory renal arteries and veins were identified at surgery in 33% (n = 9/27) and 22% (n = 6/27) of donor kidneys. The mean difference between MDCT-derived DRF and DMSA was 0.8% (95% CI 0.1-1.6) with 95% limits of agreement of -4.6% (95% CI -3.3 to -5.9) to 6.3% (95% CI 5.0-7.6). MDCT delivered a mean (SD, range) radiation dose of 9.5 (3.6, 3.6-17.3) mSv. MDCT with a triple-bolus contrast administration provides accurate anatomical and functional evaluation of living renal donors. (orig.)

  11. Computer assisted SCFE osteotomy planning

    International Nuclear Information System (INIS)

    Drapikowski, Pawel; Tyrakowski, Marcin; Czubak, Jaroslaw; Czwojdzinski, Adam

    2008-01-01

    Slipped capital femoral epiphysis (SCFE) is a common pediatric orthopedic disorder that requires surgical correction. Preoperative planning of a proximal femoral osteotomy is essential in cases of SCFE. This planning is usually done using 2D radiographs, but 3D data can be acquired with CT and analyzed with 3D visualization software. SCFEanalyzer is a computer program developed for preoperative planning of proximal femoral osteotomy to correct SCFE. Computed tomography scans were performed on human bone specimens: one pelvis and two femoral bones (right and left) and volume data of a patient. The CT data were used to test the abilities of the SCFEanalyzer software, which utilizes 3D virtual models of anatomic structures constructed from CT image data. Separation of anatomical bone structures is done by means of ''cutting'' 3D surface model of the pelvis. The software enables qualitative and quantitative spatial analysis of chosen parameters analogous to those done on the basis of plain radiographs. SCFEanalyzer makes it possible to evaluate the function of the hip joint by calculating the range of motion depending on the shape of bone structures based on oriented bounding box object representation. Pelvic and hip CT scans from a patient with SCFE were subjected to femoral geometry analysis and hip joint function assessment. These were done to plan and simulate osteotomy of the proximal femur. Analogous qualitative and quantitative evaluation after performing the virtual surgery were evaluated to determine the potential treatment effects. The use of computer assistance in preoperative planning enable us to increase objectivity and repeatability, and to compare the results of different types of osteotomy on the proximal femur, and thus to choose the optimal operation in each individual case. (orig.)

  12. Computer assisted SCFE osteotomy planning

    Energy Technology Data Exchange (ETDEWEB)

    Drapikowski, Pawel [Poznan University of Technology, Institute of Control and Information Engineering, Poznan (Poland); Tyrakowski, Marcin; Czubak, Jaroslaw; Czwojdzinski, Adam [Postgraduate Medical Education Center, Department of Orthopaedics, Warsaw (Poland)

    2008-11-15

    Slipped capital femoral epiphysis (SCFE) is a common pediatric orthopedic disorder that requires surgical correction. Preoperative planning of a proximal femoral osteotomy is essential in cases of SCFE. This planning is usually done using 2D radiographs, but 3D data can be acquired with CT and analyzed with 3D visualization software. SCFEanalyzer is a computer program developed for preoperative planning of proximal femoral osteotomy to correct SCFE. Computed tomography scans were performed on human bone specimens: one pelvis and two femoral bones (right and left) and volume data of a patient. The CT data were used to test the abilities of the SCFEanalyzer software, which utilizes 3D virtual models of anatomic structures constructed from CT image data. Separation of anatomical bone structures is done by means of ''cutting'' 3D surface model of the pelvis. The software enables qualitative and quantitative spatial analysis of chosen parameters analogous to those done on the basis of plain radiographs. SCFEanalyzer makes it possible to evaluate the function of the hip joint by calculating the range of motion depending on the shape of bone structures based on oriented bounding box object representation. Pelvic and hip CT scans from a patient with SCFE were subjected to femoral geometry analysis and hip joint function assessment. These were done to plan and simulate osteotomy of the proximal femur. Analogous qualitative and quantitative evaluation after performing the virtual surgery were evaluated to determine the potential treatment effects. The use of computer assistance in preoperative planning enable us to increase objectivity and repeatability, and to compare the results of different types of osteotomy on the proximal femur, and thus to choose the optimal operation in each individual case. (orig.)

  13. Correct diagnosis of vascular encasement and longitudinal extension of hilar cholangiocarcinoma by four-channel multidetector-row computed tomography

    International Nuclear Information System (INIS)

    Okumoto, Tadayuki; Yamada, Takayuki; Sato, Akihiro

    2009-01-01

    Accurate diagnosis of local invasion of hilar cholangiocarcinomas is challenging due to their small size and the anatomic complexity of the hepatic hilar region. On the other hand, the correct diagnosis of local invasion is essential for assuring the possibility of curative surgery. The purpose of this study was to evaluate the feasibility of four-channel multidetector-row computed tomography (MDCT) in the assessment of vascular and bile duct involvement, by which we could obtain useful information for the surgical management of hilar cholangiocarcinoma. The subjects were 18 patients for whom the extent of tumor invasion was surgically and pathologically confirmed. All patients underwent preoperative multiphasic CT scanning by MDCT. Arterial and portal dominant phases were acquired using a detector configuration of 1.25 mm x 4 mm, and both axial and multiplanar reconstructed images were interpreted. Longitudinal extension was evaluated up to second-order branches. Vascular invasion is considered to be the degree of tumor contiguity to the hepatic arteries and portal vein and was graded by CT. The longitudinal extension was correctly diagnosed in 14 patients (77.8%). Hepatic artery invasion was correctly diagnosed in 17 patients with sensitivity of 100% and specificity of 90%, respectively. Portal vein invasion was correctly diagnosed in 47 of 51 branches with sensitivity and specificity of 92.3% and 90.2%, respectively. Multiplanar reconstructed images contributed to the correct diagnosis for both vascular encasement and longitudinal tumor extension. In conclusion, MDCT is useful in preoperative evaluation of hilar cholangiocarcinoma, especially when combined with multiplanar reconstructed images. (author)

  14. Pre-operative skin preparation practices: results of the 2007 French national assessment.

    Science.gov (United States)

    Borgey, F; Thibon, P; Ertzscheid, M-A; Bernet, C; Gautier, C; Mourens, C; Bettinger, A; Aggoune, M; Galy, E; Lejeune, B; Kadi, Z

    2012-05-01

    Pre-operative skin preparation, aimed at reducing the endogenous microbial flora, is one of the main preventive measures employed to decrease the likelihood of surgical site infection. National recommendations on pre-operative management of infection risks were issued in France in 2004. To assess compliance with the French national guidelines for pre-operative skin preparation in 2007. A prospective audit was undertaken in French hospitals through interviews with patients and staff, and observation of professional practice. Compliance with five major criteria selected from the guidelines was studied: patient information, pre-operative showering, pre-operative hair removal, surgical site disinfection and documentation of these procedures. Data for 41,188 patients from all specialties at 609 facilities were analysed. Patients were issued with information about pre-operative showering in 88.2% of cases [95% confidence interval (CI) 87.9-88.5]. The recommended procedure for pre-operative showering, including hairwashing, with an antiseptic skin wash solution was followed by 70.3% of patients (95% CI 69.9-70.8); this percentage was higher when patients had received appropriate information (P pre-operative surgical hygiene, 82.3% of cases; and pre-operative site disinfection, 71.7% of cases. The essential content of the French guidelines seems to be understood, but reminders need to be issued. Some recommendations may need to be adapted for certain specialties. Copyright © 2012 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  15. Computed tomography assessment of early response to neoadjuvant therapy in colon cancer

    DEFF Research Database (Denmark)

    Dam, Claus; Lund-Rasmussen, Vera; Pløen, John

    2015-01-01

    INTRODUCTION: Using multidetector computed tomography, we aimed to assess the early response of neoadjuvant drug therapy for locally advanced colon cancer. METHODS: Computed tomography with IV contrast was acquired from 67 patients before and after up to three cycles of preoperative treatment. All...

  16. Assessment of patient satisfaction with the preoperative anesthetic evaluation

    Directory of Open Access Journals (Sweden)

    Gebremedhn EG

    2014-09-01

    Full Text Available Endale Gebreegziabher Gebremedhn, Vidhya Nagaratnam Department of Anesthesia, School of Medicine, Gondar College of Medicine and Health Sciences, University of Gondar, Gondar, Ethiopia Background: The evaluation of patient satisfaction is a core aspect of the continuous quality improvement in anesthesia service that can be affected by the preoperative anesthetist visit. This visit enables the anesthetist to know about the patient's general health status and the nature of surgery, to choose the type of anesthesia, and to discuss perioperative complications and their management with the patient. Patients have sometimes complained about the information given during the preoperative anesthetic evaluation in the University of Gondar teaching and referral hospital. The aim of this study was to determine the level of patient satisfaction with the preoperative anesthetist visit. Methods: A cross-sectional study was conducted from February 15 to April 15, 2013. All consecutive elective patients who were operated upon under anesthesia during the study period were interviewed 24 hours after operation. A pretested questionnaire and checklists, which were developed based on the hospital's anesthetic evaluation sheet, were used for data collection. Results: A total of 116 elective patients were operated upon under anesthesia during the study period. Of these, 102 patients were included in our study, with a response rate of 87.9%. Anesthetists introduced themselves to ~24% patients; provided information about anesthesia to ~32%, postoperative complications to ~21%, postoperative analgesia to ~18, and postoperative nausea and vomiting to ~21%; and spent adequate time with ~74%. Patients' questions were answered by the anesthetist in ~65% of cases, and ~65% of patients had reduced anxiety after the anesthetist visit. The patients' overall satisfaction with the preoperative anesthetist visit was ~65%. Conclusion and recommendation: Patient satisfaction with the

  17. Reactive control of subsonic axial fan noise in a duct.

    Science.gov (United States)

    Liu, Y; Choy, Y S; Huang, L; Cheng, L

    2014-10-01

    Suppressing the ducted fan noise at low frequencies without varying the flow capacity is still a technical challenge. This study examines a conceived device consisting of two tensioned membranes backed with cavities housing the axial fan for suppression of the sound radiation from the axial fan directly. The noise suppression is achieved by destructive interference between the sound fields from the axial fan of a dipole nature and sound radiation from the membrane via vibroacoustics coupling. A two-dimensional model with the flow effect is presented which allows the performance of the device to be explored analytically. The air flow influences the symmetrical behavior and excites the odd in vacuo mode response of the membrane due to kinematic coupling. Such an asymmetrical effect can be compromised with off-center alignment of the axial fan. Tension plays an important role to sustain the performance to revoke the deformation of the membrane during the axial fan operation. With the design of four appropriately tensioned membranes covered by a cylindrical cavity, the first and second blade passage frequencies of the axial fan can be reduced by at least 20 dB. The satisfactory agreement between experiment and theory demonstrates that its feasibility is practical.

  18. Preoperative Detection of Sarcopenic Obesity Helps to Predict the Occurrence of Gastric Leak After Sleeve Gastrectomy.

    Science.gov (United States)

    Gaillard, Martin; Tranchart, Hadrien; Maitre, Sophie; Perlemuter, Gabriel; Lainas, Panagiotis; Dagher, Ibrahim

    2018-03-02

    Sleeve gastrectomy (SG) has become the primary procedure for many bariatric teams and staple-line leak represents its most feared complication. Sarcopenic obesity combines the risks of obesity and depleted lean mass leading possibly to an inferior surgical outcome after abdominal surgery. The aim of this study was to evaluate the existence of a potential link between radiologically determined sarcopenic obesity and staple-line leak risk after SG. A retrospective analysis of a prospective database was performed in consecutive patients undergoing SG as primary procedure. Total psoas muscles (TPA) and total visible muscles (TMA) areas were measured on a preoperative computed tomography (CT). Sarcopenia was defined as lowest tertile of skeletal muscular mass indexes (muscular areas over square of height) in each gender (using TPA or TMA). Multivariate analysis was performed to determine preoperative risk factors for staple-line leak. During the study period, 205 patients were included in the analysis. Median BMI was 40.8 kg/m 2 (34.2-49.6), and 9 patients (4.4%) presented a gastric leak. The sex-specific cut-offs for skeletal muscular mass index according to TPA were 8.2 cm 2 /m 2 for men and 6.08 cm 2 /m 2 for women. After multivariate analysis, preoperative weight (OR = 1043) and sarcopenia (TPA) (OR = 5204) were independent predictive factors for gastric leak. The present series suggests that CT scan-determined sarcopenic obesity is associated with increased risk of gastric leak after SG. This preoperatively radiological examination would be a useful clinical tool to tailor patient management according to gastric leak risk.

  19. Preoperative localization of parathyroid tumor by computerized tomography

    International Nuclear Information System (INIS)

    Kan, Seiji; Hiraishi, Koji; Nakamura, Shoichiro; Yamamoto, Schuzo; Odachi, Motoaki; Yamashita, Toshiyuki.

    1984-01-01

    Five patients of primary hyperparathyroidism with urolithiasis underwent CT-scanning for the preoperative localization of parathyroid tumor. The tumor was identified in all patients but one, who had a multiple adenomatous goiter. In this case, postoperative observation of the CT-scan revealed the parathyroid tumor. It appears that if the size of the parathyroid tumor is about 1cm in diameter, there is a high possibility of preoperative localization by computerized tomography. (author)

  20. Chronic tuberculous empyema: relationships between preoperative CT findings and postoperative improvement measured by pulmonary function testing

    International Nuclear Information System (INIS)

    Kim, D.J.; Im, J.-G.; Goo, J.M.; Lee, H.J.; You, S.Y.; Song, J.W.

    2005-01-01

    AIMS: To evaluate whether preoperative computed tomography (CT) findings correlate with postoperative improvements in forced vital capacity (FVC) and forced expiratory volume during 1 s (FEV1) in persons who have undergone unilateral decortication because of unilateral chronic tuberculous empyema. METHODS: A retrospective study was carried out of 67 individuals who had undergone decortication because of chronic tuberculous empyema between January 1996 and December 2000. Of these, 13 subjects who had had preoperative chest CT and preoperative and postoperative pulmonary function tests (PFTs) were included in the investigation. On preoperative CT, the degree of volume reduction of the affected side was compared with that of the contralateral normal lung. The relative volume of empyema was calculated by dividing the volume occupied by the empyema by the sum of the total volume of the ipsilateral lung and the empyema volume. The thicknesses of pleura and extrapleural fat in the involved hemithorax were measured by CT at their thickest points, and the degree of atelectasis adjacent to the empyema in the diseased lung was assessed and classified. These five CT parameters and the ages of the patients were compared with preoperative and postoperative FVC and FEV1 changes. RESULTS: A significant negative correlation was found between FVC changes and the relative volume of the affected lung (FVC: p=0.039, RS=-0.58). FVC and FEV1 were found to be significantly and positively correlated with the relative volume of the empyema (FVC: p=0.005, RS=0.72; FEV1: p=0.014, RS=0.66) and the degree of atelectasis (FVC: p=0.007, RS=0.71; FEV1: p=0.029, RS=0.60) by Spearman's nonparametric correlation test. Other CT parameters and the ages of the patients were not found to be correlated with PFT changes. CONCLUSION: The relative volume of the affected side, the relative volume of empyema and the degree of atelectasis can predict improvements in FVC and FEV1 after decortication in patients