WorldWideScience

Sample records for preliminary radiological analysis

  1. Preliminary analysis of doses to evaluate the image quality in radiographic examinations in veterinary radiology

    International Nuclear Information System (INIS)

    Pinto, Ana Carolina B.C.F.; Dias, Mayara T.P.; Santos, Andrea C.; Melo, Camila S.; Furquim, Tania A.C.

    2009-01-01

    This work has as objective to promote the analysis of the radiological doses and quality of the image of the technical letter used for the accomplishment of thorax and coxal radiographic examination of animals of canine and feline species. The study was accomplished in the service of Diagnosis for Image in Veterinarian Hospital of Veterinary Medicine and Zootecnia College of University of Sao Paulo, in two conventional equipment. Initially, physical features of the animals and the technique used were collected for each one of the 188 radiographic examinations of thorax and 52 examinations of coxal. The animals were placed in different groups, according to their body weight. For each group, the averages for each feature were calculated: thickness of the radiographed region, tension, electric current, time of exhibition, current product electric-time, size of the used film, presence or absence of bucky and feature of focus (narrow or thick). On the basis of the averages of group M (of lesser weights that 5kg for cats and between 10,1kg and 20kg for dogs), was executed a physical analysis of the current technical letter, using the equipment: ionization chamber (to determinate the value of kerma in air), simulator objects (representative of the thickness of the animal) and three dispositive standards of test that evaluate space resolution, resolution in low contrast and contrast-detail. The obtained images were analyzed and compared for a physicist and a radiologist medical veterinary. The results had shown that the examinations supply dose considered high for techniques used mainly for coxal. The equipment A, although to supply higher doses, presents the better images for the majority of the projections. However, the study indicates that there are not exactly reference levels, but these examinations must pass for improvement of quality of image (author)

  2. Radiological consequence analysis. Report on the work package 10. Preliminary safety analysis for the site Gorleben; Radiologische Konsequenzanalyse. Bericht zum Arbeitspaket 10. Vorlaeufige Sicherheitsanalyse fuer den Standort Gorleben

    Energy Technology Data Exchange (ETDEWEB)

    Larue, Juergen; Baltes, Bruno; Fischer, Heidemarie; Frieling, Gerd; Kock, Ingo; Navarro, Martin; Seher, Holger

    2013-02-15

    Work package 10 of the preliminary safety analysis for the site Gorleben concerns the analysis of release scenarios and the radiological consequences. The report includes the description of the applied methodology, the concept for the mathematical description of scenarios, the variety of scenarios for the radiological consequence analysis with the definition of the reference scenario. The database for the calculation covers geology and hydrology, the final repository concept and the process of the final disposal system. The used models were the one-phase transport model MARINE and the two-phase transport model TOUGH2. The report summarizes the results including an evaluation of the realization of the demonstration concept with respect to solution transport, fluid transport, robustness of the modeling results and analogy discussion to other disposal variants (i.e. borehole disposal and storage of transport or storage casks).

  3. Preliminary radiological analysis of the transportation of contact-handled transuranic waste within the state of New Mexico. Revision 1

    International Nuclear Information System (INIS)

    Tappen, J.; Fredrickson, C.; Daer, G.

    1985-06-01

    This analysis assesses the potential radiological impacts on the citizens of New Mexico from the transport of CH-TRU waste to WIPP by rail or by truck. Assuming exclusive use of the truck transport mode, the combined annual exposure to the public from accident-free shipment of waste is estimated to be 3.3 person-rem/year. It is estimated that a theoretical member of the public receiving maximum exposure to the combined truck shipments of CH-TRU waste to WIPP would receive an annual whole body dose equivalent of 0.000016 rem. Such an exposure is insignificant in comparison to the average annual whole body dose equivalent to an individual living in the Colorado Plateau area of between 0.075 and 0.140 rem from natural occurring radiation. The combined annual radiological risk to the public living along the new Mexico truck routes to WIPP from potential accidents is projected as 0.031 person-rem/year. Assuming exclusive use of the rail transport mode, the combined annual exposure to the public from accident-free shipment of waste is estimated to be 1.2 person-rem/year. A theoretical member of the public receiving combined maximum exposure to rail shipments of CH-TRU waste to WIPP would receive an annual whole body dose equivalent of 0.000012 rem. The combined annual radiological risk to the public living along the New Mexico rail routes to WIPP from potential accidents is projected as 0.0022 person-rem/year. An estimate of the radiological impacts in a year of maximum waste receipt can be made by multiplying the above results for rail or truck by 2. This estimate is based upon the WIPP design waste throughput rate of 500,000 ft 3 per year. An estimate of the radiological impacts of CH-TRU waste transport to WIPP over the facility life can be made by multiplying the above results by 25

  4. Preliminary exploration of the postgraduate education reform in interventional radiology

    International Nuclear Information System (INIS)

    Ni Caifang; Ouyang Yong

    2012-01-01

    Interventional radiology now is facing many challenges. The education quality has declined, and the high-level professional talents have been lost. This paper aims to analyze the present situation of the postgraduate education and the relevant issues in the field of interventional radiology, and to make a preliminary exploration into how we can train the postgraduates to become qualified interventional radiologists with high comprehensive quality in order to meet the urgent requirements demanded by the development of interventional radiology. (authors)

  5. Preliminary radiological analysis of the transportation of remote-handled transuranic waste within the state of New Mexico

    International Nuclear Information System (INIS)

    Daer, G.; Harvill, J.

    1985-07-01

    This analysis assesses the potential radiological impacts on the citizens of New Mexico from the transport of RH-TRU waste to the WIPP by rail or by truck. Assuming exclusive use of the truck transport mode, the combined annual exposure to the public from accident-free shipment of waste is estimated to be 11.5 person-rem/year. It is estimated that a theoretical member of the public receiving maximum exposure to the combined truck shipments of RH-TRU waste to the WIPP would receive an annual whole body dose equivalent of 0.00072 rem. Such an exposure is insignificant in comparison to the average annual whole body dose equivalent to an individual living in the Colorado Plateau area of between 0.075 and 0.140 rem from naturally occurring radiation. The highest average annual dose commitment to any organ from potential accidents along all New Mexico truck routes to the WIPP is projected as 0.012 person-rem/year to bone surfaces. Assuming sole use of the rail transport mode, the combined annual exposure to the public from accident-free shipment of waste is estimated to be 1.3 person-rem/year. A theoretical member of the public receiving combined maximum exposure to rail shipments of RH-TRU waste to the WIPP would receive an annual whole body dose equivalent of 0.000014 rem. The highest average annual dose commitment to any organ from potential accidents along the New Mexico rail routes to the WIPP is projected as 0.0004 person-rem/year to bone surfaces

  6. Preliminary report about Goiania radiological accident, Brazil

    International Nuclear Information System (INIS)

    Oliveira, A.R. de.

    1988-05-01

    The events that originate the Goiania radiological accident involving the rupture of Cesium 137 source, the source characteristics, the medical aspects related to the triage of victims, the medical attendance, and the special measurements of decontamination in the Goiania General Hospital (HGG), are described. (M.C.K.) [pt

  7. Radiological follow-up of uncemented knee prostheses. Preliminary study

    International Nuclear Information System (INIS)

    Martin Hervas, C.; Gomez Barrena, E.; Marquez Moreno, I.; Calle Yuste, F.; Ordonez Parra, J.M.

    1993-01-01

    The preliminary results of a prospective study of 40 uncemented total knee prostheses (TKP) are presented following a radiological protocol with fluoroscopic control and follow-up of over 2 years. The prosthesis-bone interface and the components alignment were assessed. Several radiological signs were studied to assess this interface with respect to the fixing of the component, but they showed little clinical correlation. Statistical significance (p<0.05, chisquare) was found only in the observation of sclerosis in areas of support for the tibital tray as a reaction of the bone. This radiological follow-up is of interest to determine the evolution of the interface and position of the implant to prevent complications (especially loosening) in patients, particularly those under 60 years old, who represent the group that can most benefit from prosthetic systems with uncemented anchorage because of their life expectation and level of activity. Author

  8. Preliminary radiological assessments of low-level waste repositories

    International Nuclear Information System (INIS)

    Nancarrow, D.J.; Sumerling, T.J.; Ashton, J.

    1988-06-01

    Preliminary assessments of the post-closure radiological impact from the disposal of low-level radioactive wastes in shallow engineered facilities at four sites are presented. This provides a framework to practice and refine a methodology that could be used, on behalf of the Department, for independent assessment of any similar proposal from Nirex. Information and methodological improvements that would be required are identified. (author)

  9. Preliminary reports in the emergency department: is a subspecialist radiologist more accurate than a radiology resident?

    Science.gov (United States)

    Branstetter, Barton F; Morgan, Matthew B; Nesbit, Chadd E; Phillips, Jinnah A; Lionetti, David M; Chang, Paul J; Towers, Jeffrey D

    2007-02-01

    To determine whether emergency department (ED) preliminary reports rendered by subspecialist attending radiologists who are reading outside their field of expertise are more accurate than reports rendered by radiology residents, and to compare error rates between radiologists and nonradiologists in the ED setting. The study was performed at a large academic medical center with a busy ED. An electronic preliminary report generator was used in the ED to capture preliminary interpretations rendered in a clinical setting by radiology residents, junior attendings (within 2 years of taking their oral boards), senior attendings, and ED clinicians between August 1999 and November 2004. Each preliminary report was later reviewed by a final interpreting radiologist, and the preliminary interpretation was adjudicated for the presence of substantial discordances, defined as a difference in interpretation that might immediately impact the care of the patient. Of the 612,890 preliminary reports in the database, 65,780 (11%) met inclusion criteria for this study. A log-linear analysis was used to assess the effects of modality and type of author on preliminary report error rates. ED clinicians had significantly higher error rates when compared with any type of radiologist, regardless of modality. Within the radiologists, residents and junior attendings had lower error rates than did senior attendings, but the differences were not statistically significant. Subspecialized attending radiologists who interpret ED examinations outside their area of expertise have error rates similar to those of radiology residents. Nonradiologists have significantly higher error rates than radiologists and radiology residents when interpreting examinations in the ED.

  10. Informatics in radiology: web-based preliminary reporting system for radiology residents with PACS integration.

    Science.gov (United States)

    O'Connell, Timothy; Chang, Debra

    2012-01-01

    While on call, radiology residents review imaging studies and issue preliminary reports to referring clinicians. In the absence of an integrated reporting system at the training sites of the authors' institution, residents were typing and faxing preliminary reports. To partially automate the on-call resident workflow, a Web-based system for resident reporting was developed by using the free open-source xAMP Web application framework and an open-source DICOM (Digital Imaging and Communications in Medicine) software toolkit, with the goals of reducing errors and lowering barriers to education. This reporting system integrates with the picture archiving and communication system to display a worklist of studies. Patient data are automatically entered in the preliminary report to prevent identification errors and simplify the report creation process. When the final report for a resident's on-call study is available, the reporting system queries the report broker for the final report, and then displays the preliminary report side by side with the final report, thus simplifying the review process and encouraging review of all of the resident's reports. The xAMP Web application framework should be considered for development of radiology department informatics projects owing to its zero cost, minimal hardware requirements, ease of programming, and large support community.

  11. Radiologic analysis of amebiasis

    International Nuclear Information System (INIS)

    Kim, S. Y.; Lee, Y. H.; Park, C. Y.

    1980-01-01

    The amebiasis is a common diseases in Korea as well as worldwide especially frequent in tropical area such as India, Africa and South America. The diagnosis of amebiasis remain difficult and complex, despite of many diagnostic method, for example, direct stool test for ameba, many immunologic studies and biopsy. Authors analyzed radiologically the patient who have had confirmed as a amebiasis from June, 1976 to September, 1979 at Yonsei University, College of Medicine, Severance Hospital. The results as follows: 1. The amebic liver abscess was a most common from of the amebiasis in Korea, which were 40 cases among 56 cases. Plain abdomen showed huge hepatomegaly, compression and displacement in hepatic flexure of colon, and reflex gas distension in almost cases. Chest P-A showed nonspecific right lower lung findings from secondary to right upper abdominal pathology, such as elevated right diaphragm (61.3%), pleural effusion (60.0%), right lower lung consolidation (37.5%) and abscess cavities (5.0%). Liver scan showed large space occupying lesion, most commonly situated in right lobe of liver (68.6%). 2. Among total 15 cases of the amebic colitis, positive findings on barium enema were 80%. Barium enama showed spas and irritability (89.2%), narrowing of lumen and lack of distensibility (71.4%) and deformity of cecum (20.0%). Involved site was cecum, ascending colon, rectosigmoid, transeverse and descending colon in order of frequency. Unusual involvement of terminal ileum was 2 cases. 3. Combined cases of amebic liver abscess and colitis were 4 cases (27.7%).

  12. Preliminary characterization of dose in personnel of interventional radiology

    International Nuclear Information System (INIS)

    Godolfim, Laura Larre; Anes, Mauricio; Bacelar, Alexandre; Lykawka, Rochelle

    2016-01-01

    Exposure to X-rays of Interventional Radiology professionals (IR) impacts in the high dose rate received by these individuals, and there are reports of biological effects of this professional activity. Therefore, it is fomented greater control over the doses received by these workers. This research intends to characterize the doses received by the professionals during IR procedures. We evaluated the doses of radiologists, anesthesiologists and nursing staff of the Hospital de Clinicas de Porto Alegre, through measures with dosimeters of the OSL type, distributed in up to six regions of the body of these professionals. Until now were accompanied 33 cholangiography procedures and 29 embolization procedures. As a preliminary result, it was possible to identify a wide variation between doses of the professionals of the same function in each procedure. In overview, the dose of the professionals presented in descending order as a radiologist 1> radiologist 2 > anesthetist > nursing. (author)

  13. Radiology workstation for mammography: preliminary observations, eyetracker studies, and design

    Science.gov (United States)

    Beard, David V.; Johnston, Richard E.; Pisano, Etta D.; Hemminger, Bradley M.; Pizer, Stephen M.

    1991-07-01

    For the last four years, the UNC FilmPlane project has focused on constructing a radiology workstation facilitating CT interpretations equivalent to those with film and viewbox. Interpretation of multiple CT studies was originally chosen because handling such large numbers of images was considered to be one of the most difficult tasks that could be performed with a workstation. The authors extend the FilmPlane design to address mammography. The high resolution and contrast demands coupled with the number of images often cross- compared make mammography a difficult challenge for the workstation designer. This paper presents the results of preliminary work with workstation interpretation of mammography. Background material is presented to justify why the authors believe electronic mammographic workstations could improve health care delivery. The results of several observation sessions and a preliminary eyetracker study of multiple-study mammography interpretations are described. Finally, tentative conclusions of what a mammographic workstation might look like and how it would meet clinical demand to be effective are presented.

  14. UVISS preliminary visibility analysis

    DEFF Research Database (Denmark)

    Betto, Maurizio

    1998-01-01

    The goal of this work is to obtain a preliminary assessment of the sky visibility for anastronomical telescope located on the express pallet of the International SpaceStation (ISS)} taking into account the major constraints imposed on the instrument by the ISSattitude and structure. Part of the w......The goal of this work is to obtain a preliminary assessment of the sky visibility for anastronomical telescope located on the express pallet of the International SpaceStation (ISS)} taking into account the major constraints imposed on the instrument by the ISSattitude and structure. Part...... of the work is also to setup the kernel of a software tool for the visibility analysis thatshould be easily expandable to consider more complex strucures for future activities.This analysis is part of the UVISS assessment study and it is meant to provide elementsfor the definition and the selection...

  15. Preliminary hazards analysis -- vitrification process

    International Nuclear Information System (INIS)

    Coordes, D.; Ruggieri, M.; Russell, J.; TenBrook, W.; Yimbo, P.

    1994-06-01

    This paper presents a Preliminary Hazards Analysis (PHA) for mixed waste vitrification by joule heating. The purpose of performing a PHA is to establish an initial hazard categorization for a DOE nuclear facility and to identify those processes and structures which may have an impact on or be important to safety. The PHA is typically performed during and provides input to project conceptual design. The PHA is then followed by a Preliminary Safety Analysis Report (PSAR) performed during Title 1 and 2 design. The PSAR then leads to performance of the Final Safety Analysis Report performed during the facility's construction and testing. It should be completed before routine operation of the facility commences. This PHA addresses the first four chapters of the safety analysis process, in accordance with the requirements of DOE Safety Guidelines in SG 830.110. The hazards associated with vitrification processes are evaluated using standard safety analysis methods which include: identification of credible potential hazardous energy sources; identification of preventative features of the facility or system; identification of mitigative features; and analyses of credible hazards. Maximal facility inventories of radioactive and hazardous materials are postulated to evaluate worst case accident consequences. These inventories were based on DOE-STD-1027-92 guidance and the surrogate waste streams defined by Mayberry, et al. Radiological assessments indicate that a facility, depending on the radioactive material inventory, may be an exempt, Category 3, or Category 2 facility. The calculated impacts would result in no significant impact to offsite personnel or the environment. Hazardous materials assessment indicates that a Mixed Waste Vitrification facility will be a Low Hazard facility having minimal impacts to offsite personnel and the environment

  16. Preliminary hazards analysis -- vitrification process

    Energy Technology Data Exchange (ETDEWEB)

    Coordes, D.; Ruggieri, M.; Russell, J.; TenBrook, W.; Yimbo, P. [Science Applications International Corp., Pleasanton, CA (United States)

    1994-06-01

    This paper presents a Preliminary Hazards Analysis (PHA) for mixed waste vitrification by joule heating. The purpose of performing a PHA is to establish an initial hazard categorization for a DOE nuclear facility and to identify those processes and structures which may have an impact on or be important to safety. The PHA is typically performed during and provides input to project conceptual design. The PHA is then followed by a Preliminary Safety Analysis Report (PSAR) performed during Title 1 and 2 design. The PSAR then leads to performance of the Final Safety Analysis Report performed during the facility`s construction and testing. It should be completed before routine operation of the facility commences. This PHA addresses the first four chapters of the safety analysis process, in accordance with the requirements of DOE Safety Guidelines in SG 830.110. The hazards associated with vitrification processes are evaluated using standard safety analysis methods which include: identification of credible potential hazardous energy sources; identification of preventative features of the facility or system; identification of mitigative features; and analyses of credible hazards. Maximal facility inventories of radioactive and hazardous materials are postulated to evaluate worst case accident consequences. These inventories were based on DOE-STD-1027-92 guidance and the surrogate waste streams defined by Mayberry, et al. Radiological assessments indicate that a facility, depending on the radioactive material inventory, may be an exempt, Category 3, or Category 2 facility. The calculated impacts would result in no significant impact to offsite personnel or the environment. Hazardous materials assessment indicates that a Mixed Waste Vitrification facility will be a Low Hazard facility having minimal impacts to offsite personnel and the environment.

  17. Analysis of radiology business models.

    Science.gov (United States)

    Enzmann, Dieter R; Schomer, Donald F

    2013-03-01

    As health care moves to value orientation, radiology's traditional business model faces challenges to adapt. The authors describe a strategic value framework that radiology practices can use to best position themselves in their environments. This simplified construct encourages practices to define their dominant value propositions. There are 3 main value propositions that form a conceptual triangle, whose vertices represent the low-cost provider, the product leader, and the customer intimacy models. Each vertex has been a valid market position, but each demands specific capabilities and trade-offs. The underlying concepts help practices select value propositions they can successfully deliver in their competitive environments. Copyright © 2013 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  18. Data analysis for radiological characterisation: Geostatistical and statistical complementarity

    International Nuclear Information System (INIS)

    Desnoyers, Yvon; Dubot, Didier

    2012-01-01

    Radiological characterisation may cover a large range of evaluation objectives during a decommissioning and dismantling (D and D) project: removal of doubt, delineation of contaminated materials, monitoring of the decontamination work and final survey. At each stage, collecting relevant data to be able to draw the conclusions needed is quite a big challenge. In particular two radiological characterisation stages require an advanced sampling process and data analysis, namely the initial categorization and optimisation of the materials to be removed and the final survey to demonstrate compliance with clearance levels. On the one hand the latter is widely used and well developed in national guides and norms, using random sampling designs and statistical data analysis. On the other hand a more complex evaluation methodology has to be implemented for the initial radiological characterisation, both for sampling design and for data analysis. The geostatistical framework is an efficient way to satisfy the radiological characterisation requirements providing a sound decision-making approach for the decommissioning and dismantling of nuclear premises. The relevance of the geostatistical methodology relies on the presence of a spatial continuity for radiological contamination. Thus geo-statistics provides reliable methods for activity estimation, uncertainty quantification and risk analysis, leading to a sound classification of radiological waste (surfaces and volumes). This way, the radiological characterization of contaminated premises can be divided into three steps. First, the most exhaustive facility analysis provides historical and qualitative information. Then, a systematic (exhaustive or not) surface survey of the contamination is implemented on a regular grid. Finally, in order to assess activity levels and contamination depths, destructive samples are collected at several locations within the premises (based on the surface survey results) and analysed. Combined with

  19. Results of the preliminary radiological survey at the former Diamond Magnesium Company site, Luckey, Ohio (DML001)

    International Nuclear Information System (INIS)

    Foley, R.D.; Crutcher, J.W.

    1990-02-01

    As part of the Formerly Utilized Sites Remedial Action Program, the US Department of Energy (DOE) is implementing a radiological survey program to determine the radiological conditions at sites that were used by the department's predecessor agencies. One such site is the former Diamond Magnesium Company facility in Luckey, Ohio. The preliminary radiological survey discussed in this report was conducted at the request of DOE by members of the Measurement Applications and Development group of Oak Ridge National Laboratory in December 1988. The former Diamond Magnesium Company site in Luckey, Ohio, was used as a magnesium reduction plant during World War 2. It was closed in 1945 and reopened in 1949 as a beryllium production facility, operated by Brush Wellman for the US Atomic Energy Commission. The preliminary radiological survey included: a surface gamma scan of part of the property outdoors, collection of surface and subsurface soil samples, and collection of water samples. Laboratory analysis of soil samples showed concentrations of 226 Ra in excess of applicable DOE guidelines. A follow-up, detailed survey is recommended. 9 refs., 10 figs., 4 tabs

  20. Pickering safeguards: a preliminary analysis

    International Nuclear Information System (INIS)

    Todd, J.L.; Hodgkinson, J.G.

    1977-05-01

    A summary is presented of thoughts relative to a systems approach for implementing international safeguards. Included is a preliminary analysis of the Pickering Generating Station followed by a suggested safeguards system for the facility

  1. Analysis of the Radiology Reports from Radiology Clinics

    International Nuclear Information System (INIS)

    Kim, Eun Jin; Kwack, Kyu Sung; Cho, Jae Hyun; Jang, Eun Ho

    2009-01-01

    The purpose of this study was to investigate the form and content of the radiology reports from radiology clinics in Korea. One hundred and sixty six radiology reports from 49 radiology clinics were collected, and these reports were referred to the academic tertiary medical center from March 2008 to February 2009. These included reports for CT (n = 18), MRI (n = 146) and examinations not specified (n = 2). Each report was evaluated for the presence of required contents (demographics, technical information, findings, conclusion, the name, license number and signature of the radiologist and the referring facility). These requirements were based on the guideline of the American College of Radiology and the previous research. The name of the patient, the gender, the body part, the type of examination, the time of examination and the conclusion, the name of the radiologist and the name of facility were well recorded in over 90% of the radiology reports. However, the identification number of the patient, the referring facility, the referring physician, the use of contrast material, the clinical information, the time of dictation, the signature of the radiologist and the license number of the radiologist were poorly recorded (less than 50%). The optimal format of a radiology report should be established for reliable and valid communication with clinicians

  2. Preliminary report of radiological safety to hydrology 1993 campaign

    International Nuclear Information System (INIS)

    Badano, A.; Suarez Antola, R.; Dellepere, A.; Barreiro, M.

    1993-01-01

    This report has been prepared based on the interaction between project managers and division radiological Protection and Nuclear Safety. In seeking to establish a basis for approval from the point of view of radiation safety practices . The idea for the audit has been provided at all times because the interest was the exchange of ideas and the use of common sense to improve the safety of radioactive substances, security of operators and public safety and environment.The above shows that in the planned radiation safety condition described in this report,the practice can be carried out according to the criteria of safety accepted .

  3. Radiology

    International Nuclear Information System (INIS)

    Bigot, J.M.; Moreau, J.F.; Nahum, H.; Bellet, M.

    1990-01-01

    The 17th International Congress of Radiology was conducted in two separate scientific sessions, one for radiodiagnosis and one for radiation oncology. Topics covered are: Radiobiology -radioprotection; imaging and data processing; contrast media; MRI; nuclear medicine; radiology and disasters; radiology of tropical diseases; cardiovascular radiology; interventional radiology; imaging of trauma; imaging of chest, gastro-intestinal tract, breast and genito-urinary tract; imaging in gynecology;imaging in oncology; bone and joint radiology; head and neck-radiology; neuro-radiology. (H.W.). refs.; fig.; tabs

  4. Preliminary radiological consequence estimates for a reference LEU core for PARR

    International Nuclear Information System (INIS)

    Ali Khan, L.

    1990-01-01

    Radiological consequence analysis of a reference LEU core for Pakistan Research Reactor (PARR) has been carried out using mathematical models. It was assumed that 20% of the fuel, having an average burn-up of 50% achieved by continuously operating the reactor for 300 days at 10 MW, fails. It was further assumed that 100% of the noble gases and a fraction of iodine are released. Three modes of leakage from reactor building have been considered. These are exhaust through the normal ventilation system, through emergency ventilation system and leakage from the building. The whole body and thyroid doses have been calculated for 2 hours and 30 days at the boundaries of the exclusion zone at 450m and the low population zone at 1000m. For the releases at stack height through normal and emergency ventilation system, doses at both the boundaries remain within emergency dose limits of 300 rem for thyroid and 25 rem for the whole body. However, in the case of direct release from the containment building, the limiting thyroid dose of 300 rem, at 1000m, for 30 days exposure is achieved for a leak rate of 27% per day under Pasquill condition E. The results presented in this report are only preliminary estimates. A more accurate detailed analysis for various burnups will be carried out using standard computer codes

  5. Preliminary radiological consequence estimate for a reference LEU core for PARR

    International Nuclear Information System (INIS)

    Younus, M.; Khan, L.A.; Akhtar, K.M.; Pervez, S.

    1988-07-01

    Radiological consequence analysis of a reference LEU core for Pakistan Research Reactor (PARR) has been carried out using mathematical models. Three modes of leakage from reactor building have been considered. These are exhaust through the normal ventilation system, through emergency ventilation system and leakage from the building. The whole body and thyroid does have been calculated for the duration of 2 hours and 30 days at the boundaries of exclusion zone at 450m and low population zone at 100m. For the releases at stack height through normal and emergency ventilation systems, does at both the boundaries remain within relevant emergency does limits of 300 rem for thyroid and 25 rem for whole body. However, in case of direct release from the containment building, limiting thyroid does of 300 rem, at 1000m, for 30 days exposure is achieved for a leak rate of 27% per day under Pasquill condition E. The results presented in this report are only preliminary estimates. A more accurate detailed analysis, for various burnups, will be carried using standard computer codes. (orig./A.B)

  6. Preliminary Hazards Analysis Plasma Hearth Process

    International Nuclear Information System (INIS)

    Aycock, M.; Coordes, D.; Russell, J.; TenBrook, W.; Yimbo, P.

    1993-11-01

    This Preliminary Hazards Analysis (PHA) for the Plasma Hearth Process (PHP) follows the requirements of United States Department of Energy (DOE) Order 5480.23 (DOE, 1992a), DOE Order 5480.21 (DOE, 1991d), DOE Order 5480.22 (DOE, 1992c), DOE Order 5481.1B (DOE, 1986), and the guidance provided in DOE Standards DOE-STD-1027-92 (DOE, 1992b). Consideration is given to ft proposed regulations published as 10 CFR 830 (DOE, 1993) and DOE Safety Guide SG 830.110 (DOE, 1992b). The purpose of performing a PRA is to establish an initial hazard categorization for a DOE nuclear facility and to identify those processes and structures which may have an impact on or be important to safety. The PHA is typically performed during and provides input to project conceptual design. The PRA then is followed by a Preliminary Safety Analysis Report (PSAR) performed during Title I and II design. This PSAR then leads to performance of the Final Safety Analysis Report performed during construction, testing, and acceptance and completed before routine operation. Radiological assessments indicate that a PHP facility, depending on the radioactive material inventory, may be an exempt, Category 3, or Category 2 facility. The calculated impacts would result in no significant impact to offsite personnel or the environment. Hazardous material assessments indicate that a PHP facility will be a Low Hazard facility having no significant impacts either onsite or offsite to personnel and the environment

  7. Preliminary radiological assessments of near-surface low-level radioactive waste repositories

    International Nuclear Information System (INIS)

    Sumerling, T.J.; Nancarrow, D.J.

    1988-08-01

    This report summarises preliminary assessments of post-closure radiological impact of LLW repositories at four sites previously under investigation by UK Nirex Ltd. The objectives of the assessments were: to demonstrate a methodology for site specific assessments, to identify important information requirements for detailed assessments; to identify methodological and research requirements. Doses and risks due to groundwater pathways, human intrusion, gaseous release and natural environmental change are estimated. (author)

  8. Preliminary HECTOR analysis by Dragon

    Energy Technology Data Exchange (ETDEWEB)

    Presser, W; Woloch, F

    1972-06-02

    From the different cores measured in HECTOR, only ACH 4/B-B was selected for the Dragon analysis, since it presented the largest amount of uniform fuel loading in the central test region and is therefore nearest to an infinite lattice. Preliminary results are discussed.

  9. ICPP radiological and toxicological sabotage analysis

    International Nuclear Information System (INIS)

    Kubiak, V.R.; Mortensen, F.G.

    1995-01-01

    In June of 1993, the Department of Energy (DOE) issued Notice 5630.3A, open-quotes Protection of Departmental Facilities Against Radiological and Toxicological Sabotage,close quotes which states that all significant radiological and toxicological hazards at Department facilities must be examined for potential sabotage. This analysis has been completed at the Idaho Chemical Processing Plant (ICPP). The ICPP radiological and toxicological hazards include spent government and commercial fuels, Special Nuclear Materials (SNM), high-level liquid wastes, high-level solid wastes, and process and decontamination chemicals. The analysis effort included identification and assessment of quantities of hazardous materials present at the facility; identification and ranking of hazardous material targets; development of worst case scenarios detailing possible sabotage actions and hazard releases; performance of vulnerability assessments using table top and computer methodologies on credible threat targets; evaluation of potential risks to the public, workers, and the environment; evaluation of sabotage risk reduction options; and selection of cost effective prevention and mitigation options

  10. Concept Overview & Preliminary Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ruth, Mark

    2017-07-12

    'H2@Scale' is an opportunity for wide-scale use of hydrogen as an intermediate that carries energy from various production options to multiple uses. It is based on identifying and developing opportunities for low-cost hydrogen production and investigating opportunities for using that hydrogen across the electricity, industrial, and transportation sectors. One of the key production opportunities is use of low-cost electricity that may be generated under high penetrations of variable renewable generators such as wind and solar photovoltaics. The technical potential demand for hydrogen across the sectors is 60 million metric tons per year. The U.S. has sufficient domestic renewable resources so that each could meet that demand and could readily meet the demand using a portfolio of generation options. This presentation provides an overview of the concept and the technical potential demand and resources. It also motivates analysis and research on H2@Scale.

  11. Radiology

    International Nuclear Information System (INIS)

    Edholm, P.R.

    1990-01-01

    This is a report describing diagnostic techniques used in radiology. It describes the equipment necessary for, and the operation of a radiological department. Also is described the standard methods used in radiodiagnosis. (K.A.E.)

  12. Preliminary radiological readings on the old uraniferous mining site of Rophin (Puy-de-Dome)

    International Nuclear Information System (INIS)

    Chareyron, Bruno

    2012-01-01

    After a presentation of the site, of the objectives, limits and methodology of the measurement campaign, this document reports and comments the radiological measurements performed by the CRIIRAD on the old uranium mining site of Rophin and its surroundings (gamma radiation). It comments measurements performed 1 meter above the ground and on soils, and anomalies clearly related to past industrial activities. It comments the results of a radiological analysis performed on released waters (uranium 238, radon 222), and on sediments and soils

  13. Fractal-Based Image Analysis In Radiological Applications

    Science.gov (United States)

    Dellepiane, S.; Serpico, S. B.; Vernazza, G.; Viviani, R.

    1987-10-01

    We present some preliminary results of a study aimed to assess the actual effectiveness of fractal theory and to define its limitations in the area of medical image analysis for texture description, in particular, in radiological applications. A general analysis to select appropriate parameters (mask size, tolerance on fractal dimension estimation, etc.) has been performed on synthetically generated images of known fractal dimensions. Moreover, we analyzed some radiological images of human organs in which pathological areas can be observed. Input images were subdivided into blocks of 6x6 pixels; then, for each block, the fractal dimension was computed in order to create fractal images whose intensity was related to the D value, i.e., texture behaviour. Results revealed that the fractal images could point out the differences between normal and pathological tissues. By applying histogram-splitting segmentation to the fractal images, pathological areas were isolated. Two different techniques (i.e., the method developed by Pentland and the "blanket" method) were employed to obtain fractal dimension values, and the results were compared; in both cases, the appropriateness of the fractal description of the original images was verified.

  14. Indexing thoracic CT reports using a preliminary version of a standardized radiological lexicon (RadLex).

    Science.gov (United States)

    Marwede, Dirk; Schulz, Thomas; Kahn, Thomas

    2008-12-01

    To validate a preliminary version of a radiological lexicon (RadLex) against terms found in thoracic CT reports and to index report content in RadLex term categories. Terms from a random sample of 200 thoracic CT reports were extracted using a text processor and matched against RadLex. Report content was manually indexed by two radiologists in consensus in term categories of Anatomic Location, Finding, Modifier, Relationship, Image Quality, and Uncertainty. Descriptive statistics were used and differences between age groups and report types were tested for significance using Kruskal-Wallis and Mann-Whitney Test (significance level <0.05). From 363 terms extracted, 304 (84%) were found and 59 (16%) were not found in RadLex. Report indexing showed a mean of 16.2 encoded items per report and 3.2 Finding per report. Term categories most frequently encoded were Modifier (1,030 of 3,244, 31.8%), Anatomic Location (813, 25.1%), Relationship (702, 21.6%) and Finding (638, 19.7%). Frequency of indexed items per report was higher in older age groups, but no significant difference was found between first study and follow up study reports. Frequency of distinct findings per report increased with patient age (p < 0.05). RadLex already covers most terms present in thoracic CT reports based on a small sample analysis from one institution. Applications for report encoding need to be developed to validate the lexicon against a larger sample of reports and address the issue of automatic relationship encoding.

  15. Analysis and radiological assessment of survey results and samples from the beaches around Sellafield

    International Nuclear Information System (INIS)

    Webb, G.A.M.; Fry, F.A.

    1983-12-01

    After radioactive sea debris had been found on beaches near the BNFL, Sellafield, plant, NRPB was asked by the Department of the Environment to analyse some of the samples collected and to assess the radiological hazard to members of the public. A report is presented containing an analysis of survey reports for the period 19 November - 4 December 1983 and preliminary results of the analysis of all samples received, together with the Board's recommendations. (author)

  16. Radiological error: analysis, standard setting, targeted instruction and teamworking

    International Nuclear Information System (INIS)

    FitzGerald, Richard

    2005-01-01

    Diagnostic radiology does not have objective benchmarks for acceptable levels of missed diagnoses [1]. Until now, data collection of radiological discrepancies has been very time consuming. The culture within the specialty did not encourage it. However, public concern about patient safety is increasing. There have been recent innovations in compiling radiological interpretive discrepancy rates which may facilitate radiological standard setting. However standard setting alone will not optimise radiologists' performance or patient safety. We must use these new techniques in radiological discrepancy detection to stimulate greater knowledge sharing, targeted instruction and teamworking among radiologists. Not all radiological discrepancies are errors. Radiological discrepancy programmes must not be abused as an instrument for discrediting individual radiologists. Discrepancy rates must not be distorted as a weapon in turf battles. Radiological errors may be due to many causes and are often multifactorial. A systems approach to radiological error is required. Meaningful analysis of radiological discrepancies and errors is challenging. Valid standard setting will take time. Meanwhile, we need to develop top-up training, mentoring and rehabilitation programmes. (orig.)

  17. Decontamination analysis of a radiologically contaminated site

    International Nuclear Information System (INIS)

    Tawil, J.J.; Strenge, D.L.

    1984-02-01

    This paper presents an analysis of decontamination options at the NUWAZX-83 exercise site. Held in May 1983, the purpose of the exercise was to evaluate the ability of federal, state and local officials to respond to a radiological accident involving nuclear weapons. A computer program developed by Pacific Northwest Laboratory was used to conduct the decontamination analysis. The program, called DECON, was designed to assist personnel engaged in the planning of decontamination activities. The many features of DECON that are demonstrated in this paper contribute to its potential usefulness as a planning tool for site restoration. Strategies that are analyzed with DECON include: (1) using a Quick-Vac option, under which exterior surfaces are vacuumed before it rains; (2) protecting surfaces against precipitation; (3) prohibiting specific operations on selected surfaces; (4) requiring that specific methods be used on selected surfaces; (5) evaluating the trade-off between cleanup standards and decontamination costs; and (6) varying clean-up standards according to expected human exposure to the surface

  18. Radiology

    International Nuclear Information System (INIS)

    Sykora, A.

    2006-01-01

    In this text-book basic knowledge about radiology, biomedical diagnostic methods (radiography, computer tomography), nuclear medicine and safety and radiation protection of personnel on the radiodiagnostic place of work are presented

  19. Emergency radiological monitoring and analysis: Federal Radiological Monitoring and Assessment Center

    International Nuclear Information System (INIS)

    Thome, D.J.

    1995-01-01

    The US Federal Radiological Emergency Response Plan (FRERP) provides the framework for integrating the various Federal agencies responding to a major radiological emergency. The FRERP authorizes the creation of the Federal Radiological Monitoring and Assessment Center (FRMAC), which is established to coordinate all Federal agencies involved in the monitoring and assessment of the off-site radiological conditions in support of the impacted State(s) and the Lead Federal Agency (LFA). Within the FRMAC, the Monitoring and Analysis Division (M ampersand A) is responsible for coordinating all FRMAC assets involved in conducting a comprehensive program of environmental monitoring, sampling, radioanalysis, and quality assurance. To assure consistency, completeness, and the quality of the data produced, a methodology and procedures manual is being developed. This paper discusses the structure, assets, and operations of the FRMAC M ampersand A and the content and preparation of the manual

  20. Emergency radiological monitoring and analysis United States Federal Radiological Monitoring and Assessment Center

    International Nuclear Information System (INIS)

    Thome, D.J.

    1994-01-01

    The United States Federal Radiological Emergency Response Plan (FRERP) provides the framework for integrating the various Federal agencies responding to a major radiological emergency. Following a major radiological incident the FRERP authorizes the creation of the Federal Radiological Monitoring and Assessment Center (FRMAC). The FRMAC is established to coordinate all Federal agencies involved in the monitoring and assessment of the off-site radiological conditions in support of the impacted states and the Lead Federal Agency (LFA). Within the FRMAC, the Monitoring and Analysis Division is responsible for coordinating all FRMAC assets involved in conducting a comprehensive program of environmental monitoring, sampling, radioanalysis and quality assurance. This program includes: (1) Aerial Radiological Monitoring - Fixed Wing and Helicopter, (2) Field Monitoring and Sampling, (3) Radioanalysis - Mobile and Fixed Laboratories, (4) Radiation Detection Instrumentation - Calibration and Maintenance, (5) Environmental Dosimetry, and (6) An integrated program of Quality Assurance. To assure consistency, completeness and the quality of the data produced, a methodology and procedures handbook is being developed. This paper discusses the structure, assets and operations of FRMAC monitoring and analysis and the content and preparation of this handbook

  1. Preliminary analysis of doses to evaluate the image quality in radiographic examinations in veterinary radiology;Analise preliminar das doses para avaliacao da qualidade da imagem em exames radiograficos na radiologia veterinaria

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Ana Carolina B.C.F.; Dias, Mayara T.P.; Santos, Andrea C. [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia; Melo, Camila S.; Furquim, Tania A.C. [Universidade de Sao Paulo (IEE/USP), SP (Brazil). Inst. de Eletrotecnica e Energia

    2009-07-01

    This work has as objective to promote the analysis of the radiological doses and quality of the image of the technical letter used for the accomplishment of thorax and coxal radiographic examination of animals of canine and feline species. The study was accomplished in the service of Diagnosis for Image in Veterinarian Hospital of Veterinary Medicine and Zootecnia College of University of Sao Paulo, in two conventional equipment. Initially, physical features of the animals and the technique used were collected for each one of the 188 radiographic examinations of thorax and 52 examinations of coxal. The animals were placed in different groups, according to their body weight. For each group, the averages for each feature were calculated: thickness of the radiographed region, tension, electric current, time of exhibition, current product electric-time, size of the used film, presence or absence of bucky and feature of focus (narrow or thick). On the basis of the averages of group M (of lesser weights that 5kg for cats and between 10,1kg and 20kg for dogs), was executed a physical analysis of the current technical letter, using the equipment: ionization chamber (to determinate the value of kerma in air), simulator objects (representative of the thickness of the animal) and three dispositive standards of test that evaluate space resolution, resolution in low contrast and contrast-detail. The obtained images were analyzed and compared for a physicist and a radiologist medical veterinary. The results had shown that the examinations supply dose considered high for techniques used mainly for coxal. The equipment A, although to supply higher doses, presents the better images for the majority of the projections. However, the study indicates that there are not exactly reference levels, but these examinations must pass for improvement of quality of image (author)

  2. Preliminary Context Analysis of Community Informatics Social ...

    African Journals Online (AJOL)

    Preliminary context analysis is always part of the feasibility study phase in the development of information system for Community Development (CD) purposes. In this paper, a context model and a preliminary context analysis are presented for Social Network Web Application (SNWA) for CD in the Niger Delta region of ...

  3. Cost-benefit analysis in decision making for diagnostic radiology

    International Nuclear Information System (INIS)

    Fabrikant, J.I.; Hilberg, A.W.

    1982-02-01

    This paper reviews certain current concepts and methods relating to benefit-risk analysis, in terms of economic costs and raidation risks to health, in relation to the benefits from diagnostic radiology in clinical medicine

  4. Radiology

    International Nuclear Information System (INIS)

    Meyers, M.A.

    1989-01-01

    This paper reports on disease processes originating within the alimentary tract, may extend through the extraperitoneal spaces, and abnormalities primarily arising within other extraperitoneal sites may significantly affect the bowel. Symptoms and signs may be obscure, delayed, or nonspecific, and the area is generally not accessible to auscultation, palpation, or percussion. Radiologic evaluation thus plays a critical role

  5. Preliminary radiological safety assessment for decommissioning of thoria dissolver of the 233U pilot plant, Trombay

    International Nuclear Information System (INIS)

    Priya, S.; Srinivasan, P.; Gopalakrishnan, R. K.

    2012-01-01

    The thoria dissolver, used for separation of 233 U from reactor-irradiated thorium metal and thorium oxide rods, is no longer operational. It was decided to carry out assessment of the radiological status of the dissolver cell for planning of the future decommissioning/dismantling operations. The dissolver interiors are expected to be contaminated with the dissolution remains of irradiated thorium oxide rods in addition to some of the partially dissolved thoria pellets. Hence, 220 Rn, a daughter product of 228 Th is of major radiological concern. Airborne activity of thoron daughters 212 Pb (Th-B) and 212 Bi (Th-C) was estimated by air sampling followed by high-resolution gamma spectrometry of filter papers. By measuring the full-energy peaks counts in the energy windows of 212 Pb, 212 Bi and 208 Tl, concentrations of thoron progeny in the sampled air were estimated by applying the respective intrinsic peak efficiency factors and suitable correction factors for the equilibration effects of 212 Pb and 212 Bi in the filter paper during the delay between sampling and counting. Then the thoron working level (TWL) was evaluated using the International Commission on Radiological Protection (ICRP) methodology. Finally, the potential effective dose to the workers, due to inhalation of thoron and its progeny during dismantling operations was assessed by using dose conversion factors recommended by ICRP. Analysis of filter papers showed a maximum airborne thoron progeny concentration of 30 TWLs inside the dissolver. (authors)

  6. Original Article PRELIMINARY BIOAUTOGRAPHIC ANALYSIS OF ...

    African Journals Online (AJOL)

    PRELIMINARY BIOAUTOGRAPHIC ANALYSIS OF THE SEEDS OF GLYPHAEA BREVIS. (SPRENG) MONACHINO FOR ANTIOXIDANT AND ANTIBACTERIAL PRINCIPLES. Michael Lahai1, Tiwalade Adewale Olugbade2. 1Department of Pharmaceutical Chemistry, Faculty of Pharmaceutical Sciences, College of Medicine ...

  7. Preliminary Analysis of Reinforced Concrete Waffle Walls

    National Research Council Canada - National Science Library

    Shugar, Theodore

    1997-01-01

    A preliminary analytical method based upon modified plate bending theory is offered for structural analysis of a promising new construction method for walls of small buildings and residential housing...

  8. Increased error rates in preliminary reports issued by radiology residents working more than 10 consecutive hours overnight.

    Science.gov (United States)

    Ruutiainen, Alexander T; Durand, Daniel J; Scanlon, Mary H; Itri, Jason N

    2013-03-01

    To determine if the rate of major discrepancies between resident preliminary reports and faculty final reports increases during the final hours of consecutive 12-hour overnight call shifts. Institutional review board exemption status was obtained for this study. All overnight radiology reports interpreted by residents on-call between January 2010 and June 2010 were reviewed by board-certified faculty and categorized as major discrepancies if they contained a change in interpretation with the potential to impact patient management or outcome. Initial determination of a major discrepancy was at the discretion of individual faculty radiologists based on this general definition. Studies categorized as major discrepancies were secondarily reviewed by the residency program director (M.H.S.) to ensure consistent application of the major discrepancy designation. Multiple variables associated with each report were collected and analyzed, including the time of preliminary interpretation, time into shift study was interpreted, volume of studies interpreted during each shift, day of the week, patient location (inpatient or emergency department), block of shift (2-hour blocks for 12-hour shifts), imaging modality, patient age and gender, resident identification, and faculty identification. Univariate risk factor analysis was performed to determine the optimal data format of each variable (ie, continuous versus categorical). A multivariate logistic regression model was then constructed to account for confounding between variables and identify independent risk factors for major discrepancies. We analyzed 8062 preliminary resident reports with 79 major discrepancies (1.0%). There was a statistically significant increase in major discrepancy rate during the final 2 hours of consecutive 12-hour call shifts. Multivariate analysis confirmed that interpretation during the last 2 hours of 12-hour call shifts (odds ratio (OR) 1.94, 95% confidence interval (CI) 1.18-3.21), cross

  9. Preclosure radiological safety analysis for accident conditions of the potential Yucca Mountain Repository: Underground facilities

    International Nuclear Information System (INIS)

    Ma, C.W.; Sit, R.C.; Zavoshy, S.J.; Jardine, L.J.; Laub, T.W.

    1992-06-01

    This preliminary preclosure radiological safety analysis assesses the scenarios, probabilities, and potential radiological consequences associated with postulated accidents in the underground facility of the potential Yucca Mountain repository. The analysis follows a probabilistic-risk-assessment approach. Twenty-one event trees resulting in 129 accident scenarios are developed. Most of the scenarios have estimated annual probabilities ranging from 10 -11 /yr to 10 -5 /yr. The study identifies 33 scenarios that could result in offsite doses over 50 mrem and that have annual probabilities greater than 10 -9 /yr. The largest offsite dose is calculated to be 220 mrem, which is less than the 500 mrem value used to define items important to safety in 10 CFR 60. The study does not address an estimate of uncertainties, therefore conclusions or decisions made as a result of this report should be made with caution

  10. Hydrothermal Liquefaction Treatment Preliminary Hazard Analysis Report

    Energy Technology Data Exchange (ETDEWEB)

    Lowry, Peter P.; Wagner, Katie A.

    2015-08-31

    A preliminary hazard assessment was completed during February 2015 to evaluate the conceptual design of the modular hydrothermal liquefaction treatment system. The hazard assessment was performed in 2 stages. An initial assessment utilizing Hazard Identification and Preliminary Hazards Analysis (PHA) techniques identified areas with significant or unique hazards (process safety-related hazards) that fall outside of the normal operating envelope of PNNL and warranted additional analysis. The subsequent assessment was based on a qualitative What-If analysis. This analysis was augmented, as necessary, by additional quantitative analysis for scenarios involving a release of hazardous material or energy with the potential for affecting the public.

  11. Radiological follow-up of uncemented knee prostheses. Preliminary study. Seguimiento radiologico de protesis de rodilla no cementadas. Estudio preliminar

    Energy Technology Data Exchange (ETDEWEB)

    Martin Hervas, C.; Gomez Barrena, E.; Marquez Moreno, I.; Calle Yuste, F.; Ordoez Parra, J.M.

    1993-10-01

    The preliminary results of a prospective study of 40 uncemented total knee prostheses (TKP) are presented following a radiological protocol with fluoroscopic control and follow-up of over 2 years. The prosthesis-bone interface and the components alignment were assessed. Several radiological signs were studied to assess this interface with respect to the fixing of the component, but they showed little clinical correlation. Statistical significance (p<0.05, chisquare) was found only in the observation of sclerosis in areas of support for the tibital tray as a reaction of the bone. This radiological follow-up is of interest to determine the evolution of the interface and position of the implant to prevent complications (especially loosening) in patients, particularly those under 60 years old, who represent the group that can most benefit from prosthetic systems with uncemented anchorage because of their life expectation and level of activity. Author

  12. Predicting visual semantic descriptive terms from radiological image data: preliminary results with liver lesions in CT.

    Science.gov (United States)

    Depeursinge, Adrien; Kurtz, Camille; Beaulieu, Christopher; Napel, Sandy; Rubin, Daniel

    2014-08-01

    We describe a framework to model visual semantics of liver lesions in CT images in order to predict the visual semantic terms (VST) reported by radiologists in describing these lesions. Computational models of VST are learned from image data using linear combinations of high-order steerable Riesz wavelets and support vector machines (SVM). In a first step, these models are used to predict the presence of each semantic term that describes liver lesions. In a second step, the distances between all VST models are calculated to establish a nonhierarchical computationally-derived ontology of VST containing inter-term synonymy and complementarity. A preliminary evaluation of the proposed framework was carried out using 74 liver lesions annotated with a set of 18 VSTs from the RadLex ontology. A leave-one-patient-out cross-validation resulted in an average area under the ROC curve of 0.853 for predicting the presence of each VST. The proposed framework is expected to foster human-computer synergies for the interpretation of radiological images while using rotation-covariant computational models of VSTs to 1) quantify their local likelihood and 2) explicitly link them with pixel-based image content in the context of a given imaging domain.

  13. Radiological release analysis for the EFR project

    International Nuclear Information System (INIS)

    Carluec, B.; Dechelette, S.; Balard, F.

    1996-01-01

    Tile safety approach of the European Fast Reactor project (EFR) requires to deal with certain hypothetical CDA and therefore to enhance the containment structure in order to mitigate the consequences. The analyses are performed in order to design a containment taking advantages of die inherent characteristics of the liquid metal fast reactor. Adequate computer codes describing the sequences which follow the core disruptive accident, are used. One of the main tool is the computer code CONTAIN-LMR. The goal of these analyses is to identify the most sensitive phenomena such as the overpressure due to sodium fire, to assess the involvement of some design parameters such as the leaktightness of the structures, the arrangement of the ventilation system- the effects of the implementation of filters or a retention chamber. The results of the calculations allow to propose a robust containment for EFR, and to verify that the radiological releases in the environment can be limited. The paper presents the safety approach of EFR adopted with regard to the accidents leading to a radiological source term, and the main design options retained for the containment of EFR. Then, the methods used to describe the phenomena and some representative calculations, will be presented. The main useful information and knowledge which derive from these studies for the designers conclude the paper. (author)

  14. Radiology

    International Nuclear Information System (INIS)

    Lissner, J.

    1985-01-01

    Diagnostic radiology is still the foremost of all innovative medical disciplines. This has many advantages but also some handicaps, e.g. the siting problem of medical equipment whose clinical potential is not fully known. This applies in particular to nuclear spin tomography, where the Laender governments and the Scientific Council seen to agree that all universities should have the appropriate equipment as soon as possible in order to intensify interdisciplinary research. Formerly, in the case of computerized tomography, there was less readiness. As a result, the siting of CT equipment is less organically structured. A special handicap of innovative fields is the problem of training and advanced training. The Chamber of Medicine and the Association of Doctors Participating in the Health Insurance Plan have issued regulations aimed at a better standardisation in this field. (orig.) [de

  15. A methodology for radiological accidents analysis in industrial gamma radiography

    International Nuclear Information System (INIS)

    Silva, F.C.A. da.

    1990-01-01

    A critical review of 34 published severe radiological accidents in industrial gamma radiography, that happened in 15 countries, from 1960 to 1988, was performed. The most frequent causes, consequences and dose estimation methods were analysed, aiming to stablish better procedures of radiation safety and accidents analysis. The objective of this work is to elaborate a radiological accidents analysis methodology in industrial gamma radiography. The suggested methodology will enable professionals to determine the true causes of the event and to estimate the dose with a good certainty. The technical analytical tree, recommended by International Atomic Energy Agency to perform radiation protection and nuclear safety programs, was adopted in the elaboration of the suggested methodology. The viability of the use of the Electron Gamma Shower 4 Computer Code System to calculate the absorbed dose in radiological accidents in industrial gamma radiography, mainly at sup(192)Ir radioactive source handling situations was also studied. (author)

  16. Radiologic analysis of congenital limb anomalies

    International Nuclear Information System (INIS)

    Chung, Hong Jun; Kim, Ok Hwa; Shinn, Kyung Sub; Kim, Nam Ae

    1994-01-01

    Congenital limb anomalies are manifested in various degree of severity and complexity bearing conclusion for description and nomenclature of each anomaly. We retrospectively analyzed the roentgenograms of congenital limb anomalies for the purpose of further understanding of the radiologic manifestations based on the embryonal defect and also to find the incidence of each anomaly. Total number of the patients was 89 with 137 anomalies. Recently the uniform system of classification for congenital anomalies of the upper limb was adopted by International Federation of Societies for Surgery of the Hand (IFSSH), which were categorized as 7 classifications. We used the IFSSH classification with some modification as 5 classifications; failure of formation of parts, failure of differentiation of parts, duplications, overgrowth and undergrowth. The patients with upper limb anomalies were 65 out of 89(73%), lower limb were 21(24%), and both upper and lower limb anomalies were 3(4%). Failure of formation was seen in 18%, failure of differentiation 39%, duplications 39%, overgrowth 8%, and undergrowth in 12%. Thirty-five patients had more than one anomaly, and 14 patients had intergroup anomalies. The upper limb anomalies were more common than lower limb. Among the anomalies, failure of differentiation and duplications were the most common types of congenital limb anomalies. Patients with failure of formation, failure of differentiation, and undergrowth had intergroup association of anomalies, but duplication and overgrowth tended to be isolated anomalies

  17. 100 classic papers of interventional radiology: A citation analysis.

    Science.gov (United States)

    Crockett, Matthew T; Browne, Ronan Fj; MacMahon, Peter J; Lawler, Leo

    2015-04-28

    To define the 100 citation classic papers of interventional radiology. Using the database of Journal Citation Reports the 40 highest impact factor radiology journals were chosen. From these journals the 100 most cited interventional radiology papers were chosen and analysed. The top paper received 2497 citations and the 100(th) paper 200 citations. The average number of citations was 320. Dates of publication ranged from 1953 - 2005. Most papers originated in the United States (n = 67) followed by Italy (n = 20) and France (n = 10). Harvard University (n = 18) and Osped Civile (n = 11) were the most prolific institutions. Ten journals produced all of the top 100 papers with "Radiology" and "AJR" making up the majority. SN Goldberg and T Livraghi were the most prolific authors. Nearly two thirds of the papers (n = 61) were published after 1990. This analysis identifies many of the landmark interventional radiology papers and provides a fascinating insight into the changing discourse within the field. It also identifies topics, authors and institutions which have impacted greatly on the specialty.

  18. Knowledge based analysis of radiology reports using conceptual graphs

    International Nuclear Information System (INIS)

    Schroeder, M.

    1992-07-01

    The telegraphic language found in radiological reports can be well understood by a natrual language system using the underlying domain knowledge. We present the METEXA system, which emphasizes the use of radiological domain knowledge to determine the semantics of utterances. Syntactic and semantic analysis, lexical sematics and the structure of the domain model are described in some detail. A resolution-based inference engine answers relevant questions concerning the contents of the reports. As knowledge representation formalism the Conceptual Graph Theory by John Sowa has been chosen. (orig.)

  19. AP600 containment purge radiological analysis

    Energy Technology Data Exchange (ETDEWEB)

    O`Connor, M.; Schulz, J.; Tan, C. [Bechtel Power Corporation (United States)] [and others

    1995-02-01

    The AP600 Project is a passive pressurized water reactor power plant which is part of the Design Certification and First-of-a-Kind Engineering effort under the Advanced Light Water Reactor program. Included in this process is the design of the containment air filtration system which will be the subject of this paper. We will compare the practice used by previous plants with the AP600 approach to meet the goals of industry standards in sizing the containment air filtration system. The radiological aspects of design are of primary significance and will be the focus of this paper. The AP600 Project optimized the design to combine the functions of the high volumetric flow rate, low volumetric flow rate, and containment cleanup and other filtration systems into one multi-functional system. This achieves a more simplified, standardized, and lower cost design. Studies were performed to determine the possible concentrations of radioactive material in the containment atmosphere and the effectiveness of the purge system to keep concentrations within 10CFR20 limits and within offsite dose objectives. The concentrations were determined for various reactor coolant system leakage rates and containment purge modes of operation. The resultant concentrations were used to determine the containment accessibility during various stages of normal plant operation including refueling. The results of the parametric studies indicate that a dual train purge system with a capacity of 4,000 cfm per train is more than adequate to control the airborne radioactivity levels inside containment during normal plant operation and refueling, and satisfies the goals of ANSI/ANS-56.6-1986 and limits the amount of radioactive material released to the environment per ANSI/ANS 59.2-1985 to provide a safe environment for plant personnel and offsite residents.

  20. Preliminary safety analysis methodology for the SMART

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Kyoo Hwan; Chung, Y. J.; Kim, H. C.; Sim, S. K.; Lee, W. J.; Chung, B. D.; Song, J. H. [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2000-03-01

    This technical report was prepared for a preliminary safety analysis methodology of the 330MWt SMART (System-integrated Modular Advanced ReacTor) which has been developed by Korea Atomic Energy Research Institute (KAERI) and funded by the Ministry of Science and Technology (MOST) since July 1996. This preliminary safety analysis methodology has been used to identify an envelope for the safety of the SMART conceptual design. As the SMART design evolves, further validated final safety analysis methodology will be developed. Current licensing safety analysis methodology of the Westinghouse and KSNPP PWRs operating and under development in Korea as well as the Russian licensing safety analysis methodology for the integral reactors have been reviewed and compared to develop the preliminary SMART safety analysis methodology. SMART design characteristics and safety systems have been reviewed against licensing practices of the PWRs operating or KNGR (Korean Next Generation Reactor) under construction in Korea. Detailed safety analysis methodology has been developed for the potential SMART limiting events of main steam line break, main feedwater pipe break, loss of reactor coolant flow, CEA withdrawal, primary to secondary pipe break and the small break loss of coolant accident. SMART preliminary safety analysis methodology will be further developed and validated in parallel with the safety analysis codes as the SMART design further evolves. Validated safety analysis methodology will be submitted to MOST as a Topical Report for a review of the SMART licensing safety analysis methodology. Thus, it is recommended for the nuclear regulatory authority to establish regulatory guides and criteria for the integral reactor. 22 refs., 18 figs., 16 tabs. (Author)

  1. Open Access Journal Policies: A Systematic Analysis of Radiology Journals.

    Science.gov (United States)

    Narayan, Anand; Lobner, Katie; Fritz, Jan

    2018-02-01

    The open access movement has pushed for greater access to scientific knowledge by expanding access to scientific journal articles. There is limited information about the extent to which open access policies have been adopted by radiology journals. We performed a systematic analysis to ascertain the proportion of radiology journals with open access options. A search was performed with the assistance of a clinical informationist. Full and mixed English-language diagnostic and interventional radiology Web of Science journals (impact factors > 1.0) were included. Nuclear medicine, radiation oncology, physics, and solicitation-only journals were excluded. Primary outcome was open access option (yes or no) with additional outcomes including presence or absence of embargo, complete or partial copyright transfer, publication fees, and self-archiving policies. Secondary outcomes included journal citations, journal impact factors, immediacy, Eigenfactor, and article influence scores. Independent double readings were performed with differences resolved by consensus, supplemented by contacting editorial staff at each journal. In all, 125 journals were identified; review yielded 49 journals (39%, mean impact factor of 2.61). Thirty-six of the journals had open access options (73.4%), and four journals were exclusively open access (8.2%). Twelve-month embargoes were most commonly cited (90.6%) with 28.6% of journals stating that they did not require a complete transfer of copyright. Prices for open access options ranged from $750 to $4,000 (median $3,000). No statistically significant differences were found in journal impact measures comparing journals with open access options to journals without open access options. Diagnostic and interventional radiology journals have widely adopted open access options with a few radiology journals being exclusively open access. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  2. Preliminary failure mode and effect analysis

    International Nuclear Information System (INIS)

    Addison, J.V.

    1972-01-01

    A preliminary Failure Mode and Effect Analysis (FMEA) was made on the overall 5 Kwe system. A general discussion of the system and failure effect is given in addition to the tabulated FMEA and a primary block diagram of the system. (U.S.)

  3. Preliminary safety analysis report for the TFTR

    International Nuclear Information System (INIS)

    Lind, K.E.; Levine, J.D.; Howe, H.J.

    A Preliminary Safety Analysis Report has been prepared for the Tokamak Fusion Test Reactor. No accident scenarios have been identified which would result in exposures to on-site personnel or the general public in excess of the guidelines defined for the project by DOE

  4. Analysis of papers in radiological journals in recent years: a comparison of journal of Korean radiologic society and radiology

    International Nuclear Information System (INIS)

    Kim, Jin Suh; Kim, Jae Kyun; Han, Dong Bok; Lim, Tae Hwan

    1997-01-01

    The purpose of this study was to determine current trends and the mode of future development in the field of medical radiology and to promote research among the nation's radiologists by analyzing the contents of the Journal of the Korean Radiologic Society(JKRS) and Radiology. The number of articles published in JKRS each year between 1990 and 1994 was counted. The research articles in JKRS(n=740) and in Radiology(n=1748) between 1992 and 1994 were categorized according to the objective, type, topic, materials, and radiologic techniques of their contents on the basis of predetermined criteria. Domestic Masters theses(n=126) and doctoral dissertations(n=75) accepted between 1990 and 1994, and domestic materials published in international journals (n=416) between 1986 and 1994 were also categorized using the same criteria. The greatest increase in the number of articles published in JKRS was seen during 1994. The majority of these aimed to retrospectively analyse the findings of diseases while the majority of articles published in Radiology dealt prospectively with the development and/or evaluation of diagnostic methods. More variety of topics and issues was seen in Radiology than in JKRS. The number of articles of domestic materials published in international journals increased from 1986 to 1994, while the number of articles of foreign materials published in Korea was relatively stationary : A significant number of theses and dissertations dealt, mostly prospectively, with studies of pathophysiologic and/or pharmacologic mechanisms using animal models. In order to understand both current trends and the direction and mode of future developments in the field of radiology, and to be able to actively deal with challenges at the forefront of radiologic development, it is essential to review research articles published in radiology-related journals

  5. Physical and cognitive task analysis in interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, S [School of Psychology, University of Liverpool, Liverpool (United Kingdom); Healey, A [Royal Liverpool University Hospital, Liverpool (United Kingdom); Evans, J [Royal Liverpool University Hospital, Liverpool (United Kingdom); Murphy, M [Royal Liverpool University Hospital, Liverpool (United Kingdom); Crawshaw, M [Department of Psychology, University of Hull, Hull (United Kingdom); Gould, D [Royal Liverpool University Hospital, Liverpool (United Kingdom)

    2006-01-15

    AIM: To identify, describe and detail the cognitive thought processes, decision-making, and physical actions involved in the preparation and successful performance of core interventional radiology procedures. MATERIALS AND METHODS: Five commonly performed core interventional radiology procedures were selected for cognitive task analysis. Several examples of each procedure being performed by consultant interventional radiologists were videoed. The videos of those procedures, and the steps required for successful outcome, were analysed by a psychologist and an interventional radiologist. Once a skeleton algorithm of the procedures was defined, further refinement was achieved using individual interview techniques with consultant interventional radiologists. Additionally a critique of each iteration of the established algorithm was sought from non-participating independent consultant interventional radiologists. RESULTS: Detailed task descriptions and decision protocols were developed for five interventional radiology procedures (arterial puncture, nephrostomy, venous access, biopsy-using both ultrasound and computed tomography, and percutaneous transhepatic cholangiogram). Identical tasks performed within these procedures were identified and standardized within the protocols. CONCLUSIONS: Complex procedures were broken down and their constituent processes identified. This might be suitable for use as a training protocol to provide a universally acceptable safe practice at the most fundamental level. It is envisaged that data collected in this way can be used as an educational resource for trainees and could provide the basis for a training curriculum in interventional radiology. It will direct trainees towards safe practice of the highest standard. It will also provide performance objectives of a simulator model.

  6. Physical and cognitive task analysis in interventional radiology

    International Nuclear Information System (INIS)

    Johnson, S.; Healey, A.; Evans, J.; Murphy, M.; Crawshaw, M.; Gould, D.

    2006-01-01

    AIM: To identify, describe and detail the cognitive thought processes, decision-making, and physical actions involved in the preparation and successful performance of core interventional radiology procedures. MATERIALS AND METHODS: Five commonly performed core interventional radiology procedures were selected for cognitive task analysis. Several examples of each procedure being performed by consultant interventional radiologists were videoed. The videos of those procedures, and the steps required for successful outcome, were analysed by a psychologist and an interventional radiologist. Once a skeleton algorithm of the procedures was defined, further refinement was achieved using individual interview techniques with consultant interventional radiologists. Additionally a critique of each iteration of the established algorithm was sought from non-participating independent consultant interventional radiologists. RESULTS: Detailed task descriptions and decision protocols were developed for five interventional radiology procedures (arterial puncture, nephrostomy, venous access, biopsy-using both ultrasound and computed tomography, and percutaneous transhepatic cholangiogram). Identical tasks performed within these procedures were identified and standardized within the protocols. CONCLUSIONS: Complex procedures were broken down and their constituent processes identified. This might be suitable for use as a training protocol to provide a universally acceptable safe practice at the most fundamental level. It is envisaged that data collected in this way can be used as an educational resource for trainees and could provide the basis for a training curriculum in interventional radiology. It will direct trainees towards safe practice of the highest standard. It will also provide performance objectives of a simulator model

  7. 100 classic papers of interventional radiology: A citation analysis

    Science.gov (United States)

    Crockett, Matthew T; Browne, Ronan FJ; MacMahon, Peter J; Lawler, Leo

    2015-01-01

    AIM: To define the 100 citation classic papers of interventional radiology. METHODS: Using the database of Journal Citation Reports the 40 highest impact factor radiology journals were chosen. From these journals the 100 most cited interventional radiology papers were chosen and analysed. RESULTS: The top paper received 2497 citations and the 100th paper 200 citations. The average number of citations was 320. Dates of publication ranged from 1953 - 2005. Most papers originated in the United States (n = 67) followed by Italy (n = 20) and France (n = 10). Harvard University (n = 18) and Osped Civile (n = 11) were the most prolific institutions. Ten journals produced all of the top 100 papers with “Radiology” and “AJR” making up the majority. SN Goldberg and T Livraghi were the most prolific authors. Nearly two thirds of the papers (n = 61) were published after 1990. CONCLUSION: This analysis identifies many of the landmark interventional radiology papers and provides a fascinating insight into the changing discourse within the field. It also identifies topics, authors and institutions which have impacted greatly on the specialty. PMID:25918585

  8. The radiological assessment system for consequence analysis - RASCAL

    International Nuclear Information System (INIS)

    Sjoreen, A.L.; Ramsdell, J.V.; Athey, G.F.

    1996-01-01

    The Radiological Assessment System for Consequence Analysis, Version 2.1 (RASCAL 2.1) has been developed for use during a response to radiological emergencies. The model estimates doses for comparison with U.S. Environmental Protection Agency (EPA) Protective Action Guides (PAGs) and thresholds for acute health effects. RASCAL was designed to be used by U.S. Nuclear Regulatory Commission (NRC) personnel who report to the site of a nuclear accident to conduct an independent evaluation of dose and consequence projections and personnel who conduct training and drills on emergency responses. It allows consideration of the dominant aspects of the source term, transport, dose, and consequences. RASCAL consists of three computational tools: ST-DOSE, FM-DOSE, and DECAY. ST-DOSE computes source term, atmospheric transport, and dose to man from accidental airborne releases of radionuclides. The source-term calculations are appropriate for accidents at U.S. power reactors. FM-DOSE computes doses from environmental concentrations of radionuclides in the air and on the ground. DECAY computes radiological decay and daughter in-growth. RASCAL 2.1 is a DOS application that can be run under Windows 3.1 and 95. RASCAL has been the starting point for other accident consequence models, notably INTERRAS, an international version of RASCAL, and HASCAL, an expansion of RASCAL that will model radiological, biological, and chemical accidents

  9. Licensing Support System: Preliminary data scope analysis

    International Nuclear Information System (INIS)

    1989-01-01

    The purpose of this analysis is to determine the content and scope of the Licensing Support System (LSS) data base. Both user needs and currently available data bases that, at least in part, address those needs have been analyzed. This analysis, together with the Preliminary Needs Analysis (DOE, 1988d) is a first effort under the LSS Design and Implementation Contract toward developing a sound requirements foundation for subsequent design work. These reports are preliminary. Further refinements must be made before requirements can be specified in sufficient detail to provide a basis for suitably specific system specifications. This document provides a baseline for what is known at this time. Additional analyses, currently being conducted, will provide more precise information on the content and scope of the LSS data base. 23 refs., 4 figs., 8 tabs

  10. RadMAP: The Radiological Multi-sensor Analysis Platform

    International Nuclear Information System (INIS)

    Bandstra, Mark S.; Aucott, Timothy J.; Brubaker, Erik; Chivers, Daniel H.; Cooper, Reynold J.; Curtis, Joseph C.; Davis, John R.; Joshi, Tenzing H.; Kua, John; Meyer, Ross; Negut, Victor; Quinlan, Michael; Quiter, Brian J.; Srinivasan, Shreyas; Zakhor, Avideh; Zhang, Richard; Vetter, Kai

    2016-01-01

    The variability of gamma-ray and neutron background during the operation of a mobile detector system greatly limits the ability of the system to detect weak radiological and nuclear threats. The natural radiation background measured by a mobile detector system is the result of many factors, including the radioactivity of nearby materials, the geometric configuration of those materials and the system, the presence of absorbing materials, and atmospheric conditions. Background variations tend to be highly non-Poissonian, making it difficult to set robust detection thresholds using knowledge of the mean background rate alone. The Radiological Multi-sensor Analysis Platform (RadMAP) system is designed to allow the systematic study of natural radiological background variations and to serve as a development platform for emerging concepts in mobile radiation detection and imaging. To do this, RadMAP has been used to acquire extensive, systematic background measurements and correlated contextual data that can be used to test algorithms and detector modalities at low false alarm rates. By combining gamma-ray and neutron detector systems with data from contextual sensors, the system enables the fusion of data from multiple sensors into novel data products. The data are curated in a common format that allows for rapid querying across all sensors, creating detailed multi-sensor datasets that are used to study correlations between radiological and contextual data, and develop and test novel techniques in mobile detection and imaging. In this paper we will describe the instruments that comprise the RadMAP system, the effort to curate and provide access to multi-sensor data, and some initial results on the fusion of contextual and radiological data.

  11. RadMAP: The Radiological Multi-sensor Analysis Platform

    Energy Technology Data Exchange (ETDEWEB)

    Bandstra, Mark S., E-mail: msbandstra@lbl.gov [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Aucott, Timothy J. [Department of Nuclear Engineering, University of California Berkeley, CA (United States); Brubaker, Erik [Sandia National Laboratory, Livermore, CA (United States); Chivers, Daniel H.; Cooper, Reynold J. [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Curtis, Joseph C. [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Department of Nuclear Engineering, University of California Berkeley, CA (United States); Davis, John R. [Department of Nuclear Engineering, University of California Berkeley, CA (United States); Joshi, Tenzing H.; Kua, John; Meyer, Ross; Negut, Victor; Quinlan, Michael; Quiter, Brian J. [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Srinivasan, Shreyas [Department of Nuclear Engineering, University of California Berkeley, CA (United States); Department of Electrical Engineering and Computer Science, University of California Berkeley, CA (United States); Zakhor, Avideh; Zhang, Richard [Department of Electrical Engineering and Computer Science, University of California Berkeley, CA (United States); Vetter, Kai [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Department of Nuclear Engineering, University of California Berkeley, CA (United States)

    2016-12-21

    The variability of gamma-ray and neutron background during the operation of a mobile detector system greatly limits the ability of the system to detect weak radiological and nuclear threats. The natural radiation background measured by a mobile detector system is the result of many factors, including the radioactivity of nearby materials, the geometric configuration of those materials and the system, the presence of absorbing materials, and atmospheric conditions. Background variations tend to be highly non-Poissonian, making it difficult to set robust detection thresholds using knowledge of the mean background rate alone. The Radiological Multi-sensor Analysis Platform (RadMAP) system is designed to allow the systematic study of natural radiological background variations and to serve as a development platform for emerging concepts in mobile radiation detection and imaging. To do this, RadMAP has been used to acquire extensive, systematic background measurements and correlated contextual data that can be used to test algorithms and detector modalities at low false alarm rates. By combining gamma-ray and neutron detector systems with data from contextual sensors, the system enables the fusion of data from multiple sensors into novel data products. The data are curated in a common format that allows for rapid querying across all sensors, creating detailed multi-sensor datasets that are used to study correlations between radiological and contextual data, and develop and test novel techniques in mobile detection and imaging. In this paper we will describe the instruments that comprise the RadMAP system, the effort to curate and provide access to multi-sensor data, and some initial results on the fusion of contextual and radiological data.

  12. Preliminary reports of pancreas transplantation: assessment of post operative radiologic imaging

    International Nuclear Information System (INIS)

    Kim, Young Hwan; Lee, Moon Gyu; Cho, Kyoung Sik; Bang, Sun Woo; Han, Duk Jong; Auh, Yong Ho

    1994-01-01

    We report seven cases of pancreas transplantation, first performed in Korea, in the context of postsurgical radiologic studies. All patients with insulin-dependent diabetes mellitus received transplants from cadevaric(n=6) or living related donor(n=1). Retrospective analysis of 27 US(including 19 Duplex US), two CT, four MRI, and three scintigraphy for these patients was made with surgico-pathological correlation in five cases. Of the seven patients, three-month graft survival was five and one-year survival was two. One patient died of abdominal abscess following surgery. US gave the valuable information regarding the graft swelling, vascular complication, and perigraft fluid collection. RBC bleeding scan was effective of the presence or absence and location of intestinal bleeding. CT was useful in determining the extent and severity of the pancreatitis. MRI gave a little information about functional status of the grafted pancreas. The choice of appropriate imaging modalities for postsurgical work up in patients who had pancreas transplantation depends on the clinical conditions of the patients and complications suspected. Further prospective studies appear to be necessary to establish the interval and modality choice for early detection of the complication

  13. Evaluation system for the analysis of the radiological consequences (RASCAL)

    International Nuclear Information System (INIS)

    Miguel Martinez, M. J. de

    2011-01-01

    The code currently employed by the Spanish Nuclear power is the IRDAM (Interactive Rapid Dose Assessment Model). This code will now be replaced by the RASCAL (Radiological Assessment System for Consequence Analysis) version 4.0. This is a significant improvement in dose calculation for escapes to the atmosphere for radioactive emergencies. The main objective is to highlight the most significant changes introduced in the RASCAL when performing these dose estimates.

  14. Preliminary report on operational guidelines developed for use in emergency preparedness and response to a radiological dispersal device incident.

    Energy Technology Data Exchange (ETDEWEB)

    Yu, C.; Cheng, J.-J.; Kamboj, S.; Domotor, S.; Wallo, A.; Environmental Science Division; DOE

    2006-12-15

    This report presents preliminary operational guidelines and supporting work products developed through the interagency Operational Guidelines Task Group (OGT). The report consolidates preliminary operational guidelines, all ancillary work products, and a companion software tool that facilitates their implementation into one reference source document. The report is intended for interim use and comment and provides the foundation for fostering future reviews of the operational guidelines and their implementation within emergency preparedness and response initiatives in the event of a radiological dispersal device (RDD) incident. The report principally focuses on the technical derivation and presentation of the operational guidelines. End-user guidance providing more details on how to apply these operational guidelines within planning and response settings is being considered and developed elsewhere. The preliminary operational guidelines are categorized into seven groups on the basis of their intended application within early, intermediate, and long-term recovery phases of emergency response. We anticipate that these operational guidelines will be updated and refined by interested government agencies in response to comments and lessons learned from their review, consideration, and trial application. This review, comment, and trial application process will facilitate the selection of a final set of operational guidelines that may be more or less inclusive of the preliminary operational guidelines presented in this report. These and updated versions of the operational guidelines will be made available through the OGT public Web site (http://ogcms.energy.gov) as they become finalized for public distribution and comment.

  15. Decontamination analysis of a radiologically contaminated site

    International Nuclear Information System (INIS)

    Tawil, J.J.; Strenge, D.L.

    1984-01-01

    This paper presents a post-exercise analysis of decontamination options for the NUWAX-83 exercise site. Held in May 1983, the purpose of NUWAX-83 was to evaluate the ability of federal, state and local officials to respond to an accident involving nuclear weapons. A computer program, called DECON, was developed by Pacific Northwest Laboratory and used to conduct the decontamination analysis in November 1983. DECON was designed to assist personnel engaged in the planning of decontamination activities. The many features of DECON that are demonstrated in this paper contribute to its potential usefulness as a planning tool for site restoration. Strategies that are analyzed with DECON include: 1) using a Quick-Vac option, under which exterior surfaces are vacuumed before it rains; 2) protecting surfaces against precipitation; 3) prohibiting specific operations on selected surfaces; 4) requiring that specific methods be used on selected surfaces; 5) evaluating the trade-off between cleanup standards and decontamination costs; and 6) varying clean-up standards according to expected human exposure to the surface

  16. A Comprehensive Analysis of Authorship in Radiology Journals.

    Science.gov (United States)

    Dang, Wilfred; McInnes, Matthew D F; Kielar, Ania Z; Hong, Jiho

    2015-01-01

    The purpose of our study was to investigate authorship trends in radiology journals, and whether International Committee of Medical Journal Editors (ICMJE) recommendations have had an impact on these trends. A secondary objective was to explore other variables associated with authorship trends. A retrospective, bibliometric analysis of 49 clinical radiology journals published from 1946-2013 was conducted. The following data was exported from MEDLINE (1946 to May 2014) for each article: authors' full name, year of publication, primary author institution information, language of publication and publication type. Microsoft Excel Visual Basics for Applications scripts were programmed to categorize extracted data. Statistical analysis was performed to determine the overall mean number of authors per article over time, impact of ICMJE guidelines, authorship frequency per journal, country of origin, article type and language of publication. 216,271 articles from 1946-2013 were included. A univariate analysis of the mean authorship frequency per year of all articles yielded a linear relationship between time and authorship frequency. The mean number of authors per article in 1946 (1.42) was found to have increased consistently by 0.07 authors/ article per year (R² = 0.9728, Pjournals, country of origin, language of publication and article type. Overall authorship for 49 radiology journals across 68 years has increased markedly with no demonstrated impact from ICMJE guidelines. A higher number of authors per article was seen in articles from: higher impact journals, European and Asian countries, original research type, and those journals who explicitly endorse the ICMJE guidelines.

  17. Pathway analysis concepts for radiological impact assessment

    International Nuclear Information System (INIS)

    Moroney, J.R.

    1992-06-01

    The concepts underlying exposure pathways analysis are outlined with reference to the features of the two broad types of radionuclide transport models now in use - dynamic and steady-state - and the methods for constructing and developing them. By way of illustration, representative radiation doses are estimated for the four main exposure pathways likely to be involved in the land application of effluent water from Retention Pond 2 of Ranger Uranium Mines. These include: external irradiation by 226 Ra and natural uranium (Un at) in soil, ingestion of 226 Ra and Un at in food, inhalation of 222 Rn daughter products from 226 Rn in soil, and inhalation of 226 Ra and Un at in airborne dust resuspended from soil. Consideration has been given to local residents pursuing a traditional lifestyle on conclusion of the land application program. Because of the possible importance of the contribution from resuspended dust, currently available data are explored in refining the methodology for the pathway and developing a more appropriate model for it. 37 refs., 9 tabs., 6 figs

  18. Cost benefit analysis in diagnostic radiology: glossary and definitions

    International Nuclear Information System (INIS)

    Golder, W.

    1999-01-01

    Cost efficiency analyses in clinical radiology require the application of methods and techniques that are not yet part of the academic qualifications of the specialists. The procedures used are borrowed from economics, decision theory, applied social sciences, epidemiology and statistics. Many expressions hail from the angloamerican literature and are presently not yet germanized unequivocally. This survey is intended to present main terms of cost efficiency analysis in the English version as well as a German translation, to give a clear definition and, if necessary, explanatory notes, and to illustrate their application by means of concrete radiologic examples. The selection of the terms is based on the hierarchical models of health technology assessment resp. clinical outcome research by Fryback and Thronbury resp. Maisey and Hutton. In concrete terms, both the differences between benefit, outcomes, and utility and the differences between effectiveness, efficacy and efficiency and the differences between direct, indirect, intangible, and marginal costs are explained. True cost efficiency analysis is compared with cost effectiveness analysis, cost identification analysis, cost minimization analysis, and cost utility analysis. Applied social sciences are represented by the Medical Outcomes Study Short Form-36 and the QALY conception. From decision theory both the analysis of hypothetical alternatives and the Markov model are taken. Finally, sensitivity analysis and the procedures of combined statistical evaluation of comparable results (meta-analysis) are quoted. (orig.) [de

  19. Preliminary Analysis of Google+'s Privacy

    OpenAIRE

    Mahmood, Shah; Desmedt, Yvo

    2011-01-01

    In this paper we provide a preliminary analysis of Google+ privacy. We identified that Google+ shares photo metadata with users who can access the photograph and discuss its potential impact on privacy. We also identified that Google+ encourages the provision of other names including maiden name, which may help criminals performing identity theft. We show that Facebook lists are a superset of Google+ circles, both functionally and logically, even though Google+ provides a better user interfac...

  20. Preliminary embryological study of the radiological concept of retroperitoneal interfascial planes: what are the interfascial planes?

    Science.gov (United States)

    Ishikawa, Kazuo; Nakao, Shota; Murakami, Gen; Rodríguez-Vázquez, Jose Francisco; Matsuoka, Tetsuya; Nakamuro, Makoto; Shimazu, Takeshi

    2014-12-01

    Recently, the radiological concept of retroperitoneal interfascial planes has been widely accepted to explain the extension of retroperitoneal pathologies. This study aimed to explore embryologically based corroborative evidence, which remains to be elucidated, for this concept. Using serial or semi-serial transverse sections from 29 human fetuses at the 5th-25th week of fetal age, we microscopically observed the development of the retroperitoneal fasciae and other structures in the retroperitoneal connective tissue. A hypothesis for the formation of the interfascial planes was generated from the developmental study and analysis of retroperitoneal fasciae in computed tomography images from 224 patients. Whereas the loose connective tissue was uniformly distributed in the retroperitoneum by the 9th week, the primitive renal and transversalis fasciae appeared at the 10th-12th week, as previous research has noted. By the 23rd week, the renal fascia, transversalis fascia, and primitive adipose tissue of the flank pad emerged. In addition, the primitive lateroconal fascia, which runs parallel to and close to the posterior renal fascia, emerged between the renal fascia and the adipose tissue of the flank pad. Conversely, pre-existing loose connective tissue was sandwiched between the opposing fasciae and was compressed and narrowed by the developing organs and fatty tissues. Through this developmental study, we provided the hypothesis that the compressed loose connective tissue and both opposed fasciae compose the interfascial planes. Analysis of the thickened retroperitoneal fasciae in computed tomography images supported this hypothesis. Further developmental or histological studies are required to verify our hypothesis.

  1. Radiological consequence analysis of a repository for radioactive waste

    International Nuclear Information System (INIS)

    Fitzpatrick, J.; Buchheim, B.; Hoop, F.J.

    1982-01-01

    One of the methods under consideration for the disposal of radioactive wastes is emplacement in a repository within deep, continental formations. This paper presents the experience gained in developing a methodology to make an assessment of the radiological consequences both for normal operation and for possible accident situations for a specific repository design in a salt dome at Gorleben in Germany , designed to accommodate all categories of radioactive waste. Radionuclide release scenarios were derived from a systematic analysis of the facility design and proposed operational procedure. Where necessary simple numerical models for such topics as direct radiation exposure from waste containers, release and transport of radionuclides, radiolysis, heat transfer, creep and impact were developed to give a first estimate of the radiological consequences due to radionuclide releases. (author)

  2. The Radiological Safety Analysis Computer Program (RSAC-5) user's manual

    International Nuclear Information System (INIS)

    Wenzel, D.R.

    1994-02-01

    The Radiological Safety Analysis Computer Program (RSAC-5) calculates the consequences of the release of radionuclides to the atmosphere. Using a personal computer, a user can generate a fission product inventory from either reactor operating history or nuclear criticalities. RSAC-5 models the effects of high-efficiency particulate air filters or other cleanup systems and calculates decay and ingrowth during transport through processes, facilities, and the environment. Doses are calculated through the inhalation, immersion, ground surface, and ingestion pathways. RSAC+, a menu-driven companion program to RSAC-5, assists users in creating and running RSAC-5 input files. This user's manual contains the mathematical models and operating instructions for RSAC-5 and RSAC+. Instructions, screens, and examples are provided to guide the user through the functions provided by RSAC-5 and RSAC+. These programs are designed for users who are familiar with radiological dose assessment methods

  3. 75 FR 47307 - Center for Devices and Radiological Health 510(k) Working Group Preliminary Report and...

    Science.gov (United States)

    2010-08-05

    ..., and Task Force on the Utilization of Science in Regulatory Decision Making Preliminary Report and...: The 510(k) Working Group and the Task Force on the Utilization of Science in Regulatory Decision Making. Volume I is entitled ``510(k) Working Group Preliminary Report and Recommendations.'' Volume II...

  4. Preliminary evaluation of the radiological quality of the water on Bikini and Eneu Islands

    International Nuclear Information System (INIS)

    Noshkin, V.E.; Wong, K.M.; Eagle, R.J.; Brown, G.

    1975-01-01

    In June of 1975 a survey was conducted to determine the residual radioactivity in the terrestrial environment on the two main islands (Eneu and Bikini) of Bikini Atoll. The objective was to evaluate the potential radiation doses that could be received by the Bikinians scheduled to return to their atoll. This report describes the radiological quality of the groundwater during June 1975 (from data obtained from water samples collected at old and new well sites on both islets) and the cistern water on Bikini island. Based on the analyses of these samples, the cistern water from Bikini Island is both chemically and radiologically acceptable as drinking water in accordance with standard limits established by the U. S. Public Health Service. On both islands the quality of the ground water varies from one site to another. At some wells both chemical and radiological quality are acceptable; at others one or both is unacceptable according to U. S. Public Health Standards

  5. A preliminary assessment of the radiological impact of the Chernobyl reactor accident on the population of the European Community

    International Nuclear Information System (INIS)

    Morrey, M.; Brown, J.; Williams, J.A.; Crick, M.J.; Simmonds, J.R.; Hill, M.D.

    1988-01-01

    Following the Chernobyl accident the Commission of the European Communities asked the National Radiological Protection Board to carry out a preliminary assessment of the radiological consequences of the accident on the population of the European Community (EC). The aim of the study was to review information on the environmental contamination measured in member states of the EC; to make a preliminary assessment of individual and population doses for each country; to make an estimate of the resulting health impact and to indicate the effects of the various countermeasures taken by member states in terms of the reductions in both individual and population exposure which they produced. All of the main pathways by which people have been and will be exposed to radiation as a result of the accident were included in the assessment. The impact estimate is based on environmental measurements made during the month after the accident, and on calculations made using mathematical models of radionuclide transfer through the environment. The calculated effective doses to average individuals in EC countries from exposure over the next 50 years range from 0.3 μSv (in Portugal) to between about 300 and 500 μSv (in the FRG, Italy and Greece). The total collective effective dose to the population of EC countries, integrated over all time, is estimated to be about 80 000 man Sv. This may be compared to the collective effective dose from natural background radiation of about 500 000 man Sv every year. In some countries, the restrictions placed on consumption of some foods are estimated to have been effective in reducing doses to the most exposed individuals; the reduction being up to about a factor of 2. The results presented in this paper should therefore be regarded as preliminary

  6. Preliminary assessment of radiological doses in alternative waste management systems without an MRS facility

    International Nuclear Information System (INIS)

    Schneider, K.J.; Pelto, P.J.; Daling, P.M.; Lavender, J.C.; Fecht, B.A.

    1986-06-01

    This report presents generic analyses of radiological dose impacts of nine hypothetical changes in the operation of a waste management system without a monitored retrievable storage (MRS) facility. The waste management activities examined in this study include those for handling commercial spent fuel at nuclear power reactors and at the surface facilities of a deep geologic repository, and the transportation of spent fuel by rail and truck between the reactors and the repository. In the reference study system, the radiological doses to the public and to the occupational workers are low, about 170 person-rem/1000 metric ton of uranium (MTU) handled with 70% of the fuel transported by rail and 30% by truck. The radiological doses to the public are almost entirely from transportation, whereas the doses to the occupational workers are highest at the reactors and the repository. Operating alternatives examined included using larger transportation casks, marshaling rail cars into multicar dedicated trains, consolidating spent fuel at the reactors, and wet or dry transfer options of spent fuel from dry storage casks. The largest contribution to radiological doses per unit of spent fuel for both the public and occupational workers would result from use of truck transportation casks, which are smaller than rail casks. Thus, reducing the number of shipments by increasing cask sizes and capacities (which also would reduce the number of casks to be handled at the terminals) would reduce the radiological doses in all cases. Consolidating spent fuel at the reactors would reduce the radiological doses to the public but would increase the doses to the occupational workers at the reactors

  7. Preliminary investigation of the interaction between radiologists and digital radiologic work stations

    International Nuclear Information System (INIS)

    Fajardo, L.L.; McNeill, K.M.; Maloney, K.; Mockbee, B.

    1987-01-01

    Using a work station built in the authors' department, they conducted an investigation into the interaction between radiologist and a digital radiologic work station. A survey provided information regarding the experience of 18 radiologists with digital technology and their expectations of its benefits. They ranked the potential attributes of digital work stations, with spatial resolution first, followed by contrast resolution, ease of use, speed, ease of learning, and cost. Observation of the radiologists' interaction with the work station has provided recommendations for implementation of functions. The authors conclude that radiologic work station user interfaces must be intuitive and support the radiologist's task without increasing the time or effort required for the task

  8. Regression analysis of radiological parameters in nuclear power plants

    International Nuclear Information System (INIS)

    Bhargava, Pradeep; Verma, R.K.; Joshi, M.L.

    2003-01-01

    Indian Pressurized Heavy Water Reactors (PHWRs) have now attained maturity in their operations. Indian PHWR operation started in the year 1972. At present there are 12 operating PHWRs collectively producing nearly 2400 MWe. Sufficient radiological data are available for analysis to draw inferences which may be utilised for better understanding of radiological parameters influencing the collective internal dose. Tritium is the main contributor to the occupational internal dose originating in PHWRs. An attempt has been made to establish the relationship between radiological parameters, which may be useful to draw inferences about the internal dose. Regression analysis have been done to find out the relationship, if it exist, among the following variables: A. Specific tritium activity of heavy water (Moderator and PHT) and tritium concentration in air at various work locations. B. Internal collective occupational dose and tritium release to environment through air route. C. Specific tritium activity of heavy water (Moderator and PHT) and collective internal occupational dose. For this purpose multivariate regression analysis has been carried out. D. Tritium concentration in air at various work location and tritium release to environment through air route. For this purpose multivariate regression analysis has been carried out. This analysis reveals that collective internal dose has got very good correlation with the tritium activity release to the environment through air route. Whereas no correlation has been found between specific tritium activity in the heavy water systems and collective internal occupational dose. The good correlation has been found in case D and F test reveals that it is not by chance. (author)

  9. Analysis of a quality assurance program in diagnostic radiology

    International Nuclear Information System (INIS)

    Goethlin, J.H.

    1986-01-01

    Retake analysis before and after introduction of a quality assurance program showed a 45% reduction of the retake rate. The most important changes concerning equipment and organizing of labour were: (1) More detailed inspection of development machines and X-ray generators, (2) new cassettes and intensifying screens, (3) reduction of the number of film formats used, (4) information and instruction of personnel. Cost reductions and profit from increased examination rate amounted to 4.5% of the overall operating costs of the radiologic department. (author)

  10. Preliminary characterization of dose in personnel of interventional radiology; Caracterizacao preliminar da dose em profissionais de radiologia intervencionista

    Energy Technology Data Exchange (ETDEWEB)

    Godolfim, Laura Larre; Anes, Mauricio; Bacelar, Alexandre; Lykawka, Rochelle [Hospital de Clinicas de Porto Alegre (HCPA), Porto Alegre, RS (Brazil)

    2016-07-01

    Exposure to X-rays of Interventional Radiology professionals (IR) impacts in the high dose rate received by these individuals, and there are reports of biological effects of this professional activity. Therefore, it is fomented greater control over the doses received by these workers. This research intends to characterize the doses received by the professionals during IR procedures. We evaluated the doses of radiologists, anesthesiologists and nursing staff of the Hospital de Clinicas de Porto Alegre, through measures with dosimeters of the OSL type, distributed in up to six regions of the body of these professionals. Until now were accompanied 33 cholangiography procedures and 29 embolization procedures. As a preliminary result, it was possible to identify a wide variation between doses of the professionals of the same function in each procedure. In overview, the dose of the professionals presented in descending order as a radiologist 1> radiologist 2 > anesthetist > nursing. (author)

  11. Preliminary results of the Programme to follow up radiological events in the federal district of Brasilia

    International Nuclear Information System (INIS)

    Correa, R.S.; Dias, C.M.; Nicoli, I.G.

    1998-01-01

    Since 1994, Brazil's Nuclear Energy Commission (CNEN) has been operating a telephone 'hotline' and pager service in the city of Brasilia which allows members of the public to report unusual situations involving radiation sources in the Federal District of Brasilia. One report was recorded in 1994, five in 1995 and 20 in 1996. Among the devices found in the Federal District following calls by concerned citizens were: a radioactive lightning rod, items of odontological and medical X ray equipment, smoke detectors, materials with radionuclides from research institutions and toxic materials. In the three-year period from 1994 to 1996, the radioactive lightning rod and odontological and medical X ray equipment represented seventy per cent of all the materials found. Until now, the Federal District has never experienced a real radiological emergency, as there has been no incidence of a loss of control of a radioactive source. By contrast, radiological events have occurred, and the difficulty they present is of a psychological nature, since the radioactive symbol found on the materials frightens the population. These facts show that emergency planning is necessary in the Federal District because the radiological events which occurred there in 1996 represented thirty-five per cent of all the events reported in the country. (author)

  12. Preclosure radiological safety analysis for accident conditions of the potential Yucca Mountain Repository: Underground facilities; Yucca Mountain Site Characterization Project

    Energy Technology Data Exchange (ETDEWEB)

    Ma, C.W.; Sit, R.C.; Zavoshy, S.J.; Jardine, L.J. [Bechtel National, Inc., San Francisco, CA (United States); Laub, T.W. [Sandia National Labs., Albuquerque, NM (United States)

    1992-06-01

    This preliminary preclosure radiological safety analysis assesses the scenarios, probabilities, and potential radiological consequences associated with postulated accidents in the underground facility of the potential Yucca Mountain repository. The analysis follows a probabilistic-risk-assessment approach. Twenty-one event trees resulting in 129 accident scenarios are developed. Most of the scenarios have estimated annual probabilities ranging from 10{sup {minus}11}/yr to 10{sup {minus}5}/yr. The study identifies 33 scenarios that could result in offsite doses over 50 mrem and that have annual probabilities greater than 10{sup {minus}9}/yr. The largest offsite dose is calculated to be 220 mrem, which is less than the 500 mrem value used to define items important to safety in 10 CFR 60. The study does not address an estimate of uncertainties, therefore conclusions or decisions made as a result of this report should be made with caution.

  13. The Emergency Radiological Monitoring and Analysis Division of the United States Federal Radiological Monitoring and Assessment Center

    International Nuclear Information System (INIS)

    Thome, D.J.

    2000-01-01

    The U.S. Federal Radiological Emergency Response Plan (FRERP) provides the framework for integrating the various Federal agencies responding to a major radiological emergency. The FRERP authorises the creation of the Federal Radiological Monitoring and Assessment Center (FRMAC), which is established to co-ordinate all Federal agencies involved in the monitoring and assessment of the off-site radiological conditions in support of the impacted States and the Lead Federal Agency (LFA). Within the FRMAC, the Monitoring and Analysis Division is responsible for co-ordinating all FRMAC assets involved in conducting a comprehensive program of environmental monitoring, sampling, radioanalysis, and quality assurance. This program includes: 1. Aerial Radiological Monitoring - Fixed-Wing and Helicopter; 2. Field Monitoring and Sampling; 3. Radioanalysis - Mobile and Fixed Laboratories; 4. Radiation Detection Instrumentation - Calibration and Maintenance; 5. Environmental Dosimetry; 6. Integrated program of Quality Assurance. To assure consistency, completeness, and the quality of the data produced, a methodology and procedures manual is being developed. This paper discusses the structure, assets, and operations of the FRMAC Monitoring and Analysis Division and the content and preparation of the manual. (author)

  14. Analysis of the Importance of Subjects to Improve the Educational Curriculum in the Radiological Science: Focused on Radiological Technologists

    International Nuclear Information System (INIS)

    Kim, Jung Hoon; Ko, Seong Jin; Kang, Se Sik; Kim, Dong Hyun; Kim, Chang Soo

    2012-01-01

    In this study a group of experts and clinical radiological technologists were surveyed to evaluate the clinical importance of current subjects in the radiological sciences. For the data collection and analysis, an open-ended questionnaire was distributed to the group of experts, and a multiple choice questionnaire was distributed to radiological technologists. Subjects were classified into 9 groups for analysis of the importance of subjects, and in regard to the questionnaire design for measurement of variables, departments and type of hospital were set up as independent variables, and the 9 groups of subjects were set up as dependent variables. As a result, clinical radiological technologists perceived Diagnostic Imaging Technology and practical courses, including general radiography, CT and MRI, as the most clinically necessary subjects, and the group of experts placed most weight on basic courses for the major. The result of this study suggests that the curriculum should be revised in a way that combines theory and practice in order to foster radiological technologists capable of adapting to the rapidly changing healthcare environment.

  15. Repository Subsurface Preliminary Fire Hazard Analysis

    International Nuclear Information System (INIS)

    Logan, Richard C.

    2001-01-01

    This fire hazard analysis identifies preliminary design and operations features, fire, and explosion hazards, and provides a reasonable basis to establish the design requirements of fire protection systems during development and emplacement phases of the subsurface repository. This document follows the Technical Work Plan (TWP) (CRWMS M and O 2001c) which was prepared in accordance with AP-2.21Q, ''Quality Determinations and Planning for Scientific, Engineering, and Regulatory Compliance Activities''; Attachment 4 of AP-ESH-008, ''Hazards Analysis System''; and AP-3.11Q, ''Technical Reports''. The objective of this report is to establish the requirements that provide for facility nuclear safety and a proper level of personnel safety and property protection from the effects of fire and the adverse effects of fire-extinguishing agents

  16. Northern Marshall Islands radiological survey: sampling and analysis summary

    Energy Technology Data Exchange (ETDEWEB)

    Robison, W.L.; Conrado, C.L.; Eagle, R.J.; Stuart, M.L.

    1981-07-23

    A radiological survey was conducted in the Northern Marshall Islands to document reamining external gamma exposures from nuclear tests conducted at Enewetak and Bikini Atolls. An additional program was later included to obtain terrestrial and marine samples for radiological dose assessment for current or potential atoll inhabitants. This report is the first of a series summarizing the results from the terrestrial and marine surveys. The sample collection and processing procedures and the general survey methodology are discussed; a summary of the collected samples and radionuclide analyses is presented. Over 5400 samples were collected from the 12 atolls and 2 islands and prepared for analysis including 3093 soil, 961 vegetation, 153 animal, 965 fish composite samples (average of 30 fish per sample), 101 clam, 50 lagoon water, 15 cistern water, 17 groundwater, and 85 lagoon sediment samples. A complete breakdown by sample type, atoll, and island is given here. The total number of analyses by radionuclide are 8840 for /sup 241/Am, 6569 for /sup 137/Cs, 4535 for /sup 239 +240/Pu, 4431 for /sup 90/Sr, 1146 for /sup 238/Pu, 269 for /sup 241/Pu, and 114 each for /sup 239/Pu and /sup 240/Pu. A complete breakdown by sample category, atoll or island, and radionuclide is also included.

  17. Northern Marshall Islands radiological survey: sampling and analysis summary

    International Nuclear Information System (INIS)

    Robison, W.L.; Conrado, C.L.; Eagle, R.J.; Stuart, M.L.

    1981-01-01

    A radiological survey was conducted in the Northern Marshall Islands to document reamining external gamma exposures from nuclear tests conducted at Enewetak and Bikini Atolls. An additional program was later included to obtain terrestrial and marine samples for radiological dose assessment for current or potential atoll inhabitants. This report is the first of a series summarizing the results from the terrestrial and marine surveys. The sample collection and processing procedures and the general survey methodology are discussed; a summary of the collected samples and radionuclide analyses is presented. Over 5400 samples were collected from the 12 atolls and 2 islands and prepared for analysis including 3093 soil, 961 vegetation, 153 animal, 965 fish composite samples (average of 30 fish per sample), 101 clam, 50 lagoon water, 15 cistern water, 17 groundwater, and 85 lagoon sediment samples. A complete breakdown by sample type, atoll, and island is given here. The total number of analyses by radionuclide are 8840 for 241 Am, 6569 for 137 Cs, 4535 for 239+240 Pu, 4431 for 90 Sr, 1146 for 238 Pu, 269 for 241 Pu, and 114 each for 239 Pu and 240 Pu. A complete breakdown by sample category, atoll or island, and radionuclide is also included

  18. Radionuclides in Bayer process residues: previous analysis for radiological protection

    International Nuclear Information System (INIS)

    Cuccia, Valeria; Rocha, Zildete; Oliveira, Arno H. de

    2011-01-01

    Natural occurring radionuclides are present in many natural resources. Human activities may enhance concentrations of radionuclides and/or enhance potential of exposure to naturally occurring radioactive material (NORM). The industrial residues containing radionuclides have been receiving a considerable global attention, because of the large amounts of NORM containing wastes and the potential long term risks of long-lived radionuclides. Included in this global concern, this work focuses on the characterization of radioactivity in the main residues of Bayer process for alumina production: red mud and sand samples. Usually, the residues of Bayer process are named red mud, in their totality. However, in the industry where the samples were collected, there is an additional residues separation: sand and red mud. The analytical techniques used were gamma spectrometry (HPGe detector) and neutron activation analysis. The concentrations of radionuclides are higher in the red mud than in the sand. These solid residues present activities concentrations enhanced, when compared to bauxite. Further uses for the residues as building material must be more evaluated from the radiological point of view, due to its potential of radiological exposure enhancement, specially caused by radon emission. (author)

  19. Computer aided instruction. Preliminary experience in the Radiological Sciences Institute of the University of Milan

    International Nuclear Information System (INIS)

    Gardani, G.; Bertoli, M.A.; Bellomi, M.

    1987-01-01

    Computerised instruction means teaching by computer using a program that alternates information with self-checking multiple choice questions. This system was used to create a fully computerized lesson on the diagnosis and treatment of breast cancer which was then tested on a small group of madical students attending the Radiology School of the Milan University Institute of Radiological Sciences. At the end of the test, the students were asked to complete a questionnaire which was then analysed. The computer lesson consisted of 66 text messages and 21 self-checking questions. It aroused considerable interest, though the most common reason was curiosity about a novel system. The degree of fatigue caused was modest despite the fact that the computer lesson was at least as demanding as a traditional lesson, if not more so. The level of learning was considered high and optimised by the use of self-checking questions that were considered an essential element. However no student agreed to sit an official examination, even interactively, using the computer

  20. Cost accounting of radiological examinations. Cost analysis of radiological examinations of intermediate referral hospitals and general practice.

    Science.gov (United States)

    Lääperi, A L

    1996-01-01

    The purpose of this study was to analyse the cost structure of radiological procedures in the intermediary referral hospitals and general practice and to develop a cost accounting system for radiological examinations that takes into consideration all relevant cost factors and is suitable for management of radiology departments and regional planning of radiological resources. The material comprised 174,560 basic radiological examinations performed in 1991 at 5 intermediate referral hospitals and 13 public health centres in the Pirkanmaa Hospital District in Finland. All radiological departments in the hospitals were managed by a specialist in radiology. The radiology departments at the public health care centres operated on a self-referral basis by general practitioners. The data were extracted from examination lists, inventories and balance sheets; parts of the data were estimated or calculated. The radiological examinations were compiled according to the type of examination and equipment used: conventional, contrast medium, ultrasound, mammography and roentgen examinations with mobile equipment. The majority of the examinations (87%) comprised conventional radiography. For cost analysis the cost items were grouped into 5 cost factors: personnel, equipment, material, real estate and administration costs. The depreciation time used was 10 years for roentgen equipment, 5 years for ultrasound equipment and 5 to 10 years for other capital goods. An annual interest rate of 10% was applied. Standard average values based on a sample at 2 hospitals were used for the examination-specific radiologist time, radiographer time and material costs. Four cost accounting versions with varying allocation of the major cost items were designed. Two-way analysis of variance of the effect of different allocation methods on the costs and cost structure of the examination groups was performed. On the basis of the cost analysis a cost accounting program containing both monetary and

  1. Plasma brake model for preliminary mission analysis

    Science.gov (United States)

    Orsini, Leonardo; Niccolai, Lorenzo; Mengali, Giovanni; Quarta, Alessandro A.

    2018-03-01

    Plasma brake is an innovative propellantless propulsion system concept that exploits the Coulomb collisions between a charged tether and the ions in the surrounding environment (typically, the ionosphere) to generate an electrostatic force orthogonal to the tether direction. Previous studies on the plasma brake effect have emphasized the existence of a number of different parameters necessary to obtain an accurate description of the propulsive acceleration from a physical viewpoint. The aim of this work is to discuss an analytical model capable of estimating, with the accuracy required by a preliminary mission analysis, the performance of a spacecraft equipped with a plasma brake in a (near-circular) low Earth orbit. The simplified mathematical model is first validated through numerical simulations, and is then used to evaluate the plasma brake performance in some typical mission scenarios, in order to quantify the influence of the system parameters on the mission performance index.

  2. Preliminary Shielding Analysis for HCCB TBM Transport

    Science.gov (United States)

    Miao, Peng; Zhao, Fengchao; Cao, Qixiang; Zhang, Guoshu; Feng, Kaiming

    2015-09-01

    A preliminary shielding analysis on the transport of the Chinese helium cooled ceramic breeder test blanket module (HCCB TBM) from France back to China after being irradiated in ITER is presented in this contribution. Emphasis was placed on irradiation safety during transport. The dose rate calculated by MCNP/4C for the conceptual package design satisfies the relevant dose limits from IAEA that the dose rate 3 m away from the surface of the package containing low specific activity III materials should be less than 10 mSv/h. The change with location and the time evolution of dose rates after shutdown have also been studied. This will be helpful for devising the detailed transport plan of HCCB TBM back to China in the near future. supported by the Major State Basic Research Development Program of China (973 Program) (No. 2013GB108000)

  3. Preliminary study of the environmental radiological assessment for the Garigliano nuclear power plant decommissioning

    International Nuclear Information System (INIS)

    Esposito, A.M.; Sabbarese, C.; Sirignano, C.; Visciano, L.; D'Onofrio, A.D.; Lubritto, C.; Terrasi, F.

    2002-01-01

    In the last few years many nuclear installations in the world have been stopped either because they reached the end of production lifetime, or for operation problems or, like in Italy, for political decisions. This stop started the decommissioning procedure. It consists in the dismantling of the nuclear installation with appropriate controls and limitations of environmental and radiological impact which arises from these operations. The evaluation of risk and the actions needed for the population safeguard are generally inspired to the recommendations of the International Commission on Radiological Protection (ICRP), but each country faces the problem with different evaluation methodologies and calculations. That is due to different laws and environmental, social and economical context where nuclear installations are located. For this, the decommissioning operations must be separately evaluated for each nuclear installation. In this paper, we present the work carried out so far about the decommissioning of the Nuclear Power Plant of Garigliano (Caserta, Italy), which is managed by SoGIN (Societa di Gestione degli Impianti Nucleari). This Nuclear Power Plant began its activity in 1964 by using a boiling water reactor with a production of 160 MW electric power. In 1979 this nuclear installation was stopped for maintenance and operation has not been resumed until the referendum in 1986, after which all Italian nuclear plants were stopped. Now, the Nuclear Power Plant of Garigliano has the reactor isolated respect to the remaining part and all components and pipes have been drained and sealed. The underground tanks of radioactive wastes have been evacuated and decontaminated. The radioactive wastes have been completely conditioned with cementification in drums suitable to prevent outside release

  4. Ireland's recent contribution to the radiological literature; a bibliometric analysis

    LENUS (Irish Health Repository)

    Redmond, CE

    2017-04-01

    The aim of this study was to identify and analyse all articles published by Irish radiology departments in the medical literature since the year 2000. The PubMed database was searched to identify and review all articles published by radiologists based in the Republic of Ireland or Northern Ireland. Citation counts were then obtained and the top ten most cited articles were identified. There were 781 articles published during the study period. Of these, 558 (71%) were published in radiology journals and the remaining 223 (29%) were published in general medical journals. Abdominal radiology was the most represented sub-specialty (33% of all articles). There was a general trend of increased publications per year. Only 75 (9.6%) of articles were collaborative efforts by more than one radiology department. Irish radiology departments have a considerable research output and this has increased since the year 2000. More collaborative research between Irish radiology departments is encouraged

  5. Analysis of operation TEAPOT nuclear test ZUCCHINI radiological and meterological data

    International Nuclear Information System (INIS)

    Quinn, V.E.

    1987-03-01

    This report describes the Weather Service Nuclear Support Office (WSNSO) analyses of the radiological and meteorological data collected for the ZUCCHINI nuclear test of Operation TEAPOT. Inconsistencies in the radiological data and their resolution are discussed. The methods of normalizing the radiological data to a standard time and estimating fallout-arrival times are presented. The meteorological situations on event day and the following day are described. A comparison of the WSNSO fallout analysis with an analysis performed in the 1950's is presented. The radiological data used to derive the WSNSO 1986 fallout pattern are tabulated in an appendix

  6. Radiological analysis of solids around the old uranium mine of Rosglas (Morbihan). CRIIRAD N.08-119 note

    International Nuclear Information System (INIS)

    2008-01-01

    As uranium mines present significant radiological contaminations years after their exploitation, this document reports preliminary investigations performed around old uranium mines in Brittany. This preliminary work showed significant radiological anomalies, with gamma radiation fluxes between ten and twenty times higher than the natural level. Measurement procedures and results are presented. Sampling has been performed on surface soil, stones and waters. Sample processing is briefly described. Results are commented in terms of contamination by uranium 238 and 235

  7. A preliminary analysis of the risk of transporting nuclear waste to potential candidate commercial repository sites

    International Nuclear Information System (INIS)

    Madsen, M.M.

    1984-01-01

    In accordance with the provisions of the Nuclear Waste Policy Act of 1982, environmental assessments for potential candidate sites are required to provide a basis for selection of the first site for disposal of commercial radioactive waste in deep geologic repositories. A preliminary analysis of the impacts of transportation for each of the five potential sites will be described. Transportation was assumed to be entirely by truck or entirely by rail in order to obtain bounding impacts. This paper presents both radiological and nonradiological risks for the once-through fuel cycle

  8. Preliminary Evaluation of a Radiological Biomarker to Characterize the Longitudinal Evolution of Tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Muñoz-Hernando, M.; Macias, P.; Abella, M.; Desco, M.; Sharpe, S.; Vaquero, J.J.; Muñoz-Barrutia, M.

    2016-07-01

    Tuberculosis (TB) remains the world's second-deadliest disease, due to a single infectious agent. The population that has developed multidrug resistance is increasingly important boosting the interest to run assays of novel multi-antibiotic combinations. Drug assays of new chemotherapies for treating TB require following subjects to assess response at several time points. Radiological examination of the subjects is a promising technique for that task. In this context, the main objective of the present work is twofold: 1) To evaluate the performance of a tool, dedicated to the automatic segmentation of TB infected lungs in chest Computed Tomography (CT) scans; 2) To present a method to automatically compute an imaging biomarker capable to characterize the disease longitudinal evolution. The selected biomarker is based on the intensity differences between the healthy and sick lung parenchyma in chest CT scans. Our results demonstrated a good similarity between the automatically segmented lungs and those delineated using a semi-automatic tool that relays on manual corrections. Furthermore, regarding the automatic extraction of the imaging biomarker, results showed a good inter-method agreement and concordance with respect to those obtained using a visually defined set of thresholds. (Author)

  9. Preliminary study of using imaging plates to map skin dose of patients in interventional radiology procedures

    International Nuclear Information System (INIS)

    Ohuchi, H.; Satoh, T.; Eguchi, Y.; Mori, K.

    2005-01-01

    A method using europium-doped BaFBr imaging plates (IPs) has been studied for mapping entrance skin doses during interventional radiology (IR); the mapping is useful for detecting overlap between irradiation fields and determining the most exposed skin areas. IPs, which are two-dimensional radiation sensors made of photostimulated luminescence materials, have a linear dose response up to ∼100 Gy, can accurately measure doses from 1 μGy to 10 Gy and can be used repeatedly. Because the energy dependence of IPs is rather high, the IPs were characterised in this study and a sensitivity variation of ∼13% was observed for effective energies of 32.7 to 44.7 keV, which are used in IR procedures. Simulation of actual interventional cardiology procedures showed that the variation of sensitivity was within 5%, meaning that IPs are practical for measuring skin doses during IR. Moreover, the patient data can be stored online and easily called up when IR procedures must be repeated, helping to prevent radiation injuries. (authors)

  10. Activation analysis by filtered neutrons. Preliminary investigation

    International Nuclear Information System (INIS)

    Skarnemark, G.; Rodinson, T.; Skaalberg, M.; Tokay, R.K.

    1986-01-01

    In order to investigate if measuring sensibility and precision by epithermal neutron activation analysis may be improved, different types of geological and biologic test samples were radiated. The test samples were enclosed in an extra filter of tungsten or sodium in order to reduce the flux of those neutrons that otherwise would induce interfering activity in the sample. The geological test samples consist of granites containing lanthanides which had been crushed in tung- sten carbide grinder. Normally such test samples show a interferins 1 87W-activity. By use of a tungsten filter the activity was reduced by up to 60%, which resulted in a considerable improvement of sensibility and precision of the measurement. The biologic test samples consisted of evaporated urine from patients treated with the cell poison cis-platinol. A reliable method to measure the platinum content has not existed so far. This method, however, enables platinum contents as low as about 0.1 ppm to be determined which is quite adequate. To sum up this preliminary study has demonstrated that activation analysis using filtered neutrons, correctly applied, is a satisfactory method of reducing interferences without complicated and time-consuming chemical separation procedures. (O.S.)

  11. Thermoluminescent dosemeters characterization for patient dosimetry in diagnostic radiology preliminary results

    International Nuclear Information System (INIS)

    Castro, William J.; Squair, Peterson L.; Gonzaga, Natalia B.; Nogueira, Maria S.; Silva, Teogenes A. da

    2009-01-01

    The determination of the metrological characteristics of thermoluminescent (TL) dosimeters plays an important role in dosimetry of patients submitted to x-ray examinations for diagnostic purpose. Entrance surface doses can be measured with TL dosimeters to verify the compliance with the diagnostic reference levels. Organ doses can be estimated through TL measurements in an anthropomorphic phantom which it allows the radiation risk assessment. In this work, LiF:Mg,Ti (TLD-100) rod and chip thermoluminescent dosimeters were characterized considering their use for patient dosimetry in computerized tomography and mammography. Preliminary results showed that TL dosimeters have a response reproducibility of 7.8% and 4.8% and homogeneity of 18.4% and 6.5% for rod and chip shapes, respectively. (author)

  12. Preliminary study of a radiological survey in an abandoned uranium mining area in Madagascar

    Science.gov (United States)

    N, Rabesiranana; M, Rasolonirina; F, Solonjara A.; Andriambololona., Raoelina; L, Mabit

    2010-05-01

    The region of Vinaninkarena located in central Madagascar (47°02'40"E, 19°57'17"S), is known to be a high natural radioactive area. Uranium ore was extracted in this region during the 1950s and the early 1960s. In the mid-1960s, mining activities were stopped and the site abandoned. In the meantime, the region, which used to be without any inhabitants, has recently been occupied by new settlers with presumed increase in exposure of the local population to natural ionizing radiation. In order to assess radiological risk, a survey to assess the soil natural radioactivity background was conducted during the year 2004. This study was implemented in the frame of the FADES Project SP99v1b_21 entitled: Assessment of the environmental pollution by multidisciplinary approach, and the International Atomic Energy Agency Technical Cooperation Project MAG 7002 entitled: Effects of air and water pollution on human health. Global Positioning System (GPS) was used to determine the geographical coordinates of the top soil samples (0-15cm) collected. The sampling was performed using a multi integrated scale approach to estimate the spatial variability of the parameters under investigation (U, Th and K) using geo-statistical approach. A total of 205 soil samples was collected in the study site (16 km2). After humidity correction, the samples were sealed in 100 cm3 cylindrical air-tight plastic containers and stored for more than 6 months to reach a secular equilibrium between parents and short-lived progeny (226Ra and progeny, 238U and 234Th). Measurements were performed using a high-resolution HPGe Gamma-detector with a 30% relative efficiency and an energy resolution of 1.8 keV at 1332.5 keV, allowing the determination of the uranium and thorium series and 40K. In case of secular equilibrium, a non-gamma-emitting radionuclide activity was deduced from its gamma emitting progeny. This was the case for 238U (from 234Th), 226Ra (from 214Pb and 214Bi) and 232Th (from 228Ac, 212Pb or

  13. Predicting diagnostic error in radiology via eye-tracking and image analytics: Preliminary investigation in mammography

    Energy Technology Data Exchange (ETDEWEB)

    Voisin, Sophie; Tourassi, Georgia D. [Biomedical Science and Engineering Center, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Pinto, Frank [School of Engineering, Science, and Technology, Virginia State University, Petersburg, Virginia 23806 (United States); Morin-Ducote, Garnetta; Hudson, Kathleen B. [Department of Radiology, University of Tennessee Medical Center at Knoxville, Knoxville, Tennessee 37920 (United States)

    2013-10-15

    Purpose: The primary aim of the present study was to test the feasibility of predicting diagnostic errors in mammography by merging radiologists’ gaze behavior and image characteristics. A secondary aim was to investigate group-based and personalized predictive models for radiologists of variable experience levels.Methods: The study was performed for the clinical task of assessing the likelihood of malignancy of mammographic masses. Eye-tracking data and diagnostic decisions for 40 cases were acquired from four Radiology residents and two breast imaging experts as part of an IRB-approved pilot study. Gaze behavior features were extracted from the eye-tracking data. Computer-generated and BIRADS images features were extracted from the images. Finally, machine learning algorithms were used to merge gaze and image features for predicting human error. Feature selection was thoroughly explored to determine the relative contribution of the various features. Group-based and personalized user modeling was also investigated.Results: Machine learning can be used to predict diagnostic error by merging gaze behavior characteristics from the radiologist and textural characteristics from the image under review. Leveraging data collected from multiple readers produced a reasonable group model [area under the ROC curve (AUC) = 0.792 ± 0.030]. Personalized user modeling was far more accurate for the more experienced readers (AUC = 0.837 ± 0.029) than for the less experienced ones (AUC = 0.667 ± 0.099). The best performing group-based and personalized predictive models involved combinations of both gaze and image features.Conclusions: Diagnostic errors in mammography can be predicted to a good extent by leveraging the radiologists’ gaze behavior and image content.

  14. Immediately loaded implants supporting fixed prostheses in the edentulous maxilla: a preliminary clinical and radiologic report.

    Science.gov (United States)

    Bergkvist, Göran; Sahlholm, Sten; Karlsson, Ulf; Nilner, Krister; Lindh, Christina

    2005-01-01

    To evaluate the survival rate of immediately loaded ITI sand-blasted, large-grit, acid-etched (SLA) solid-screw dental implants in the edentulous maxilla after 8 months of loading. Twenty-eight patients (mean age 63 years) with edentulous maxillae each received 6 implants and 1 implant-supported fixed provisional prosthesis within 24 hours after surgery. After a mean healing time of 15 weeks, the patient received a definitive, screw-retained, implant-supported fixed prosthesis. A total of 168 implants were placed. Clinical parameters were registered after 1 month of loading with the implant-supported fixed prostheses as well as 8 months after implant placement. Radiologic examinations and assessments were made at implant placement and after 8 months. The mean marginal bone level at implant placement was 1.6 mm (range 0 to 5.1; SD 1.1) apical of the reference point (the implant shoulder). The mean marginal bone level at the 8-month follow-up was 3.2 mm (range 0.4 to 5.9; SD 1.1) apical of the reference point. Three implants failed during the healing period. The improved results in the present study might be a result of the positive effect of splinting the implants immediately after placement. ITI SLA solid-screw implants immediately loaded (ie, loaded within 24 hours of placement) and supporting fixed prostheses had successful survival rates after 8 months. The present results constitute a solid baseline for future follow-up studies.

  15. Predicting diagnostic error in radiology via eye-tracking and image analytics: Preliminary investigation in mammography

    International Nuclear Information System (INIS)

    Voisin, Sophie; Tourassi, Georgia D.; Pinto, Frank; Morin-Ducote, Garnetta; Hudson, Kathleen B.

    2013-01-01

    Purpose: The primary aim of the present study was to test the feasibility of predicting diagnostic errors in mammography by merging radiologists’ gaze behavior and image characteristics. A secondary aim was to investigate group-based and personalized predictive models for radiologists of variable experience levels.Methods: The study was performed for the clinical task of assessing the likelihood of malignancy of mammographic masses. Eye-tracking data and diagnostic decisions for 40 cases were acquired from four Radiology residents and two breast imaging experts as part of an IRB-approved pilot study. Gaze behavior features were extracted from the eye-tracking data. Computer-generated and BIRADS images features were extracted from the images. Finally, machine learning algorithms were used to merge gaze and image features for predicting human error. Feature selection was thoroughly explored to determine the relative contribution of the various features. Group-based and personalized user modeling was also investigated.Results: Machine learning can be used to predict diagnostic error by merging gaze behavior characteristics from the radiologist and textural characteristics from the image under review. Leveraging data collected from multiple readers produced a reasonable group model [area under the ROC curve (AUC) = 0.792 ± 0.030]. Personalized user modeling was far more accurate for the more experienced readers (AUC = 0.837 ± 0.029) than for the less experienced ones (AUC = 0.667 ± 0.099). The best performing group-based and personalized predictive models involved combinations of both gaze and image features.Conclusions: Diagnostic errors in mammography can be predicted to a good extent by leveraging the radiologists’ gaze behavior and image content

  16. Preliminary assessment of the radiological protection aspects of disposal of high-level waste in geologic formations

    International Nuclear Information System (INIS)

    Hill, M.D; Grimwood, P.D.

    1978-01-01

    The purpose of this study is to carry out a preliminary assessment of the potential radiological consequences of disposing of vitrified high-level radioactive waste in geologic formations. The events which could lead to the release of radioactivity from a geologic repository are reviewed and ingress of ground-water is identified as the principal mechanism by which radioactivity may be transported back to the biosphere. A mathematical model of radionuclide migration with ground-water is used to predict possible rates of release of radioactivity into fresh water from a hypothetical repository containing all the high-level waste which may be generated in the UK up to the year 2000. The individual and collective doses which could be received as a result of man's use of contaminated fresh water are evaluated. The numerical results of the study depend very much on the assumptions made and cannot be used to draw any detailed conclusions. The main result is the identification of areas where further studies are required in order to carry out a full evaluation of this disposal option. (author)

  17. Preliminary hazard analysis using sequence tree method

    International Nuclear Information System (INIS)

    Huang Huiwen; Shih Chunkuan; Hung Hungchih; Chen Minghuei; Yih Swu; Lin Jiinming

    2007-01-01

    A system level PHA using sequence tree method was developed to perform Safety Related digital I and C system SSA. The conventional PHA is a brainstorming session among experts on various portions of the system to identify hazards through discussions. However, this conventional PHA is not a systematic technique, the analysis results strongly depend on the experts' subjective opinions. The analysis quality cannot be appropriately controlled. Thereby, this research developed a system level sequence tree based PHA, which can clarify the relationship among the major digital I and C systems. Two major phases are included in this sequence tree based technique. The first phase uses a table to analyze each event in SAR Chapter 15 for a specific safety related I and C system, such as RPS. The second phase uses sequence tree to recognize what I and C systems are involved in the event, how the safety related systems work, and how the backup systems can be activated to mitigate the consequence if the primary safety systems fail. In the sequence tree, the defense-in-depth echelons, including Control echelon, Reactor trip echelon, ESFAS echelon, and Indication and display echelon, are arranged to construct the sequence tree structure. All the related I and C systems, include digital system and the analog back-up systems are allocated in their specific echelon. By this system centric sequence tree based analysis, not only preliminary hazard can be identified systematically, the vulnerability of the nuclear power plant can also be recognized. Therefore, an effective simplified D3 evaluation can be performed as well. (author)

  18. Thermal Hydraulic Analysis of K-DEMO Single Blanket Module for Preliminary Accident Analysis using MELCOR

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Sung Bo; Bang, In Cheol [UNIST, Ulsan (Korea, Republic of)

    2016-05-15

    To develop the Korean fusion commercial reactor, preliminary design concept for K-DEMO (Korean fusion demonstration reactor) has been announced by NFRI (National Fusion Research Institute). This pre-conceptual study of K-DEMO has been introduced to identify technical details of a fusion power plant for the future commercialization of fusion reactor in Korea. Before this consideration, to build the K-DEMO, accident analysis is essential. Since the Fukushima accident, which is severe accident from unexpected disaster, safety analysis of nuclear power plant has become important. The safety analysis of both fission and fusion reactors is deemed crucial in demonstrating the low radiological effect of these reactors on the environment, during severe accidents. A risk analysis of K-DEMO should be performed, as a prerequisite for the construction of a fusion reactor. In this research, thermal-hydraulic analysis of single blanket module of K-DEMO is conducted for preliminary accident analysis for K-DEMO. Further study about effect of flow distributer is conducted. The normal K-DEMO operation condition is applied to the boundary condition and simulated to verify the material temperature limit using MELCOR. MELCOR is fully integrated, relatively fast-running code developed by Sandia National Laboratories. MELCOR had been used for Light Water Reactors and fusion reactor version of MELCOR was developed for ITER accident analysis. This study shows the result of thermal-hydraulic simulation of single blanket module with MELCOR which is severe accident code for nuclear fusion safety analysis. The difference of mass flow rate for each coolant channel with or without flow distributer is presented. With flow distributer, advantage of broadening temperature gradient in the K-DEMO blanket module and increase mass flow toward first wall is obtained. This can enhance the safety of K-DEMO blanket module. Most 13 .deg. C temperature difference in blanket module is obtained.

  19. Preliminary assessment of radiological conditions at the Ranger land application area

    International Nuclear Information System (INIS)

    Kavasnicka, J.; Bywater, J.

    1992-01-01

    Some 18 GBq of uranium and 1.5 GBq of 226 Ra were disposed of by land application on the designated disposal area by March 1989. This preliminary study, which is part of a longer-term project, outlines the assessment of external gamma radiation exposures from short-lived gamma-ray emitting decay products of 226 Ra and of internal exposures from inhalation of uranium and 226 Ra resuspended from the soil surface. The effective dose equivalent from these two exposure pathways for an adult member of the public was calculated to be about 0.05 mSv.y -1 (based on a 4 hour per day occupancy of the disposal area). This dose implies a total combined load limit of 490 kBq.m -2 of uranium plus 41 kBq.m -2 of 226 Ra. It is expected that the load limit will be reduced when all pathways and more recent data are taken into the account. 8 refs., 14 tabs., 3 figs

  20. Reflux esophagitis revisited: Prospective analysis of radiologic accuracy

    International Nuclear Information System (INIS)

    Ott, D.J.; Gelfand, D.W.; Wu, W.C.

    1981-01-01

    A prospective radiologic-endoscopic study of the esophagogastric region in 266 patients, including 206 normals and 60 with esophagitis, is reported. The endoscopic classification grading severity of esophagitis was grade 1-normal; grades 2. 3. and 4-mild, moderate, and severe esophagitis, respectively. Radiology detected 22% of patient with mild esophagitis, 83% with moderate esophagitis, and 95% with severe esophagitis. Although hiatal hernia was present in 40% of normals and 89% with esophagitis, absence of radiographic hiatal hernia excluded esophagitis with 95% accuracy. The implications of this study regarding the role of radiology in evaluating patient with suspected reflux esophagitis are discussed. (orig.) [de

  1. RSVP radiology

    International Nuclear Information System (INIS)

    Kirks, D.R.; Chaffee, D.J.

    1990-01-01

    This paper develops a relative scale of value for pediatric radiology (RSVPR). Neither the HCFA/ACA Relative Value Scale nor the Workload Measurement System developed by Health and Welfare Canada specifically addressed pediatric radiologic examinations. Technical and professional charges for examinations at Children's Hospital Medical Center were reviewed and compared with time and cost analysis. A scale was developed with chest radiography (PA and lateral views) assigned a value of 1. After review by pediatric radiologic technologists, radiologic administrators, pediatric radiologists, and chairs of departments of children's hospitals, this proposed scale was modified to reflect more accurately relative value components of pediatric radiologic and imaging examinations

  2. Radiological Source Terms for Tank Farms Safety Analysis

    Energy Technology Data Exchange (ETDEWEB)

    COWLEY, W.L.

    2000-06-27

    This document provides Unit Liter Dose factors, atmospheric dispersion coefficients, breathing rates and instructions for using and customizing these factors for use in calculating radiological doses for accident analyses in the Hanford Tank Farms.

  3. RASCAL [Radiological Assessment System for Consequence AnaLysis]: A screening model for estimating doses from radiological accidents

    International Nuclear Information System (INIS)

    Sjoreen, A.L.; Athey, G.F.; Sakenas, C.A.; McKenna, T.J.

    1988-01-01

    The Radiological Assessment System for Consequence AnaLysis (RASCAL) is a new MS-DOS-based dose assessment model which has been written for the US Nuclear Regulatory Commission for use during response to radiological emergencies. RASCAL is designed to provide crude estimates of the effects of an accident while the accident is in progress and only limited information is available. It has been designed to be very simple to use and to run quickly. RASCAL is unique in that it estimates the source term based on fundamental plant conditions and does not rely solely on release rate estimation (e.g., Ci/sec of I-131). Therefore, it can estimate consequences of accidents involving unmonitored pathways or projected failures. RASCAL will replace the older model, IRDAM. 6 refs

  4. Preliminary Analysis and Selection of Mooring Solution Candidates

    DEFF Research Database (Denmark)

    Thomsen, Jonas Bjerg; Delaney, Martin

    This report covers a preliminary analysis of mooring solutions candidates for four large floating wave energy converters. The work is part of the EUDP project “Mooring Solutions for Large Wave Energy Converters” and is the outcome of "Work Package 3: Preliminary Analysis". The report further...... compose the "Milestone 4: Report on results of preliminary analysis and selection of final candidates. The report is produced by Aalborg University with input from the partner WECs Floating Power Plant, KNSwing, LEANCON and Wave Dragon. Tension Technology International (TTI) has provided a significant...

  5. Method for the analysis pre and post radiological emergency (MAPPER)

    International Nuclear Information System (INIS)

    Perez Velazquez, R.S.; Perez Gonzalez, F.; Fornet Rodriguez, O.; Mustelier Echavarria, A.; Miller Clemente, R.A.

    1998-01-01

    Everything practices associated to the employment he/she gives ionizing radiations it generates a risk, and therefore the possibility exists potentially, he/she gives occurrences he/she gives a radiological accident. Assisting it, all the entities where the nuclear techniques are applied, they should have a method that allows them to evaluate, before y/o after having happened a radiological accident, if the planning and preparation to face emergencies give this it is or it has been effective

  6. Analysis of occupational doses in interventional radiology and cardiology installations

    International Nuclear Information System (INIS)

    Vano, E.; Gonzalez, L.; Ten, J.I.; Guibelalde, E.; Fernandez, J.M.

    1997-01-01

    The relationship between patient dose (PD) and occupational dose (OD) is not easily predictable in interventional radiology installations due to a large number of factors which can modify the occupational risk (OR). In the present work an analysis is made of the four main aspects which influence OR, namely, x-ray beam used, radiation protection (RP) tools available (aprons, thyroid protectors, gloves, screens, etc) and their regular use, type and number of procedures performed (diagnostic or therapeutic, complexity level, etc), and RP training level of the specialists. High filtration x-ray beams can entail a decrease of 20% in OD. A regular use of ceiling mounted faceplates can involve dose savings up to 65%. Mean values of dose per procedure for interventional radiologists are something greater (about 15%) than those recorded for cardiologists, except for the dosimeters placed on left forearm and shoulder. The ratio between OD and PD range around 100 μSv/1,000 cGy.cm 2 . The influence of the staff RP training level on OD is difficult to assess. In the IC Service from the Madrid San Carlos University Hospital (SCUH), PD have been reduced in above 30% and OD in a factor of 3, after running some training programmes. (author)

  7. A radiologic analysis of hysterosalpinggographic finding in infertility

    International Nuclear Information System (INIS)

    Choi, Hae Young; Lee, Kyung Ja; Yoo, Seong Yul; Kim, Hee Seup

    1985-01-01

    Hysterosalpingography has been universally accepted and approved as valuable aid in the diagnosis and treatment of infertility. Radiologic and clinical analysis had been made on 200 cases of known infertile patient in Ewha Womans University Hospital from January, 1976 to August, 1979. The results are as followings: 1. In 200 cases of infertility, 90 cases (45.5%) are primary infertility and remaining 110 cases (55.5%) are secondary infertility. 2. The peak number of age distribution is 2nd decade group in 115 cases (57.5%). 3. The peak number of duration of infertility is less than 3 years in 107 cases (53,5%). 4. Abnormal uterine finding is 25 cases (12.5%) and there 4 cases (2.0%) of congenital anomaly among them. 5. Abnormal tubal finding is 120 cases (60.0%) and there are 84 cases (42.0%) of without spillage, 36 cases (18.0%) of with spillage, 51 cases (25.5%) of hydrosalpinx, 49 cases (24.5%) of simple obstruction among them. 6. Intravasation is noted in 66 cases (33.3%) among 200 cases. 7. There are significant results between the past history and the hysterosalpiingographic findings by the statistical approach. 8. Pregnancy after hysterosalpingography is noted in 16 cases (8.0%) among 200 cases.

  8. Medical SisRadiologia: a new software tool for analysis of radiological accidents and incidents in medical radiology

    International Nuclear Information System (INIS)

    Lima, Camila M. Araujo; Silva, Francisco C.A. da; Araujo, Rilton A.; Pelegrineli, Samuel Q.

    2013-01-01

    The man's exposure to ionizing radiation in health are has increased considerably due not only the great request of medical examinations as well as the improvement of the techniques used in diagnostic imaging, for example, equipment for conventional X-rays, CT scans, mammography, hemodynamic and others. Although the benefits of using of radiology techniques are unquestionable, the lack of training in radiation protection of the workers, associated with procedure errors, have been responsible for the increasing number of radiation overexposures of these workers. Sometimes these high doses are real and there is a true radiological accident. The radiation workers, named occupationally Exposed Individual (IOE), must comply with two national regulations: Governmental Decree 453/1998 of the National Agency of Sanitary Surveillance (Portaria 453/1998 ANVISA Agencia Nacional de Vigilancia Sanitaria), which establishes the basic guidelines for radiation protection in medial and dental radiology and; the Governmental Decree NR-32/2002 of the Ministry of Labour and Employment (Ministerio do Trabalho e Emprego), which establishes the basic guidelines for the worker's health. The two mandatory regulations postulate a detailed investigation in the event of radiation overexposure of an IOE. In order to advice the diagnostic institution to perform an efficient analysis, investigation and report of high doses, it is proposed the use of a computational tool named 'Medical SisRadiologia'. This software tool enables the compilation and record of radiological abnormal data occurred in a diagnostic institution. It will also facilitate the detailed analysis of the event and will increase the effectiveness and development of work performed by the Radiation Protection Service. At the end, a technical report is issued, in accordance with the regulations of the technical regulations, which could also be used as training tool to avoid another event in the future. (author)

  9. Medical SisRadiologia: a new software tool for analysis of radiological accidents and incidents in medical radiology

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Camila M. Araujo; Silva, Francisco C.A. da, E-mail: araujocamila@yahoo.com.br, E-mail: dasilva@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Araujo, Rilton A.; Pelegrineli, Samuel Q., E-mail: consultoria@maximindustrial.com.br, E-mail: samuelfisica@maximindustrial.com.br [Maxim Industrial, Rio de Janeiro, RJ (Brazil)

    2013-07-01

    The man's exposure to ionizing radiation in health are has increased considerably due not only the great request of medical examinations as well as the improvement of the techniques used in diagnostic imaging, for example, equipment for conventional X-rays, CT scans, mammography, hemodynamic and others. Although the benefits of using of radiology techniques are unquestionable, the lack of training in radiation protection of the workers, associated with procedure errors, have been responsible for the increasing number of radiation overexposures of these workers. Sometimes these high doses are real and there is a true radiological accident. The radiation workers, named occupationally Exposed Individual (IOE), must comply with two national regulations: Governmental Decree 453/1998 of the National Agency of Sanitary Surveillance (Portaria 453/1998 ANVISA Agencia Nacional de Vigilancia Sanitaria), which establishes the basic guidelines for radiation protection in medial and dental radiology and; the Governmental Decree NR-32/2002 of the Ministry of Labour and Employment (Ministerio do Trabalho e Emprego), which establishes the basic guidelines for the worker's health. The two mandatory regulations postulate a detailed investigation in the event of radiation overexposure of an IOE. In order to advice the diagnostic institution to perform an efficient analysis, investigation and report of high doses, it is proposed the use of a computational tool named 'Medical SisRadiologia'. This software tool enables the compilation and record of radiological abnormal data occurred in a diagnostic institution. It will also facilitate the detailed analysis of the event and will increase the effectiveness and development of work performed by the Radiation Protection Service. At the end, a technical report is issued, in accordance with the regulations of the technical regulations, which could also be used as training tool to avoid another event in the future. (author)

  10. Geostatistical methods for radiological evaluation and risk analysis of contaminated premises

    International Nuclear Information System (INIS)

    Desnoyers, Y.; Jeannee, N.; Chiles, J.P.; Dubot, D.

    2009-01-01

    Full text: At the end of process equipment dismantling, the complete decontamination of nuclear facilities requires the radiological assessment of residual activity levels of building structures. As stated by the IAEA, 'Segregation and characterization of contaminated materials are the key elements of waste minimization'. From this point of view, the set up of an appropriate evaluation methodology is of primordial importance. The radiological characterization of contaminated premises can be divided into three steps. First, the most exhaustive facility analysis provides historical, functional and qualitative information. Then, a systematic (exhaustive or not) control of the emergent signal is performed by means of in situ measurement methods such as surface control device combined with in situ gamma spectrometry. Besides, in order to assess the contamination depth, samples can be collected from boreholes at several locations within the premises and analyzed. Combined with historical information and emergent signal maps, such data improve and reinforce the preliminary waste zoning. In order to provide reliable estimates while avoiding supplementary investigation costs, there is therefore a crucial need for sampling optimization methods together with appropriate data processing techniques. The relevance of the geostatistical methodology relies on the presence of a spatial continuity for radiological contamination. In this case, geostatistics provides reliable methods for activity estimation, uncertainty quantification and risk analysis, which are essential decision-making tools for decommissioning and dismantling projects of nuclear installations. Besides, the ability of this geostatistical framework to provide answers to several key issues that generally occur during the clean-up preparation phase is discussed: How to optimise the investigation costs? How to deal with data quality issues? How to consistently take into account auxiliary information such as historical

  11. Preliminary safety analysis of the Gorleben site

    International Nuclear Information System (INIS)

    Bracke, G.; Fischer-Appelt, K.

    2014-01-01

    The safety requirements governing the final disposal of heat-generating radioactive waste in Germany were implemented by the Federal Ministry of Environment, Natural Conservation and Nuclear Safety (BMU) in 2010. The Ministry considers as a fundamental objective the protection of man and the environment against the hazards of radioactive waste. Unreasonable burdens and obligation for future generations shall be avoided. The main safety principles are concentration and inclusion of radioactive and other pollutants in a containment-providing rock zone. Any release of radioactive nuclides may increase the risk for men and the environment only negligibly compared to natural radiation exposure. No intervention or maintenance work shall be necessary in the post-closure phase. Retrieval/recovery of the waste shall be possible up to 500 years after closure. The Gorleben salt dome has been discussed since the 1970's as a possible repository site for heat-generating radioactive waste in Germany. The objective of the project preliminary safety analysis of the Gorleben site (VSG) was to assess if repository concepts at the Gorleben site or other sites with a comparable geology could comply with these requirements based on currently available knowledge (Fischer-Appelt, 2013; Bracke, 2013). In addition to this it was assessed if methodological approaches can be used for a future site selection procedure and which technological and conceptual considerations can be transferred to other geological situations. The objective included the compilation and review of the available exploration data of the Gorleben site and on disposal in salt rock, the development of repository designs, and the identification of the needs for future R and D work and further site investigations. (authors)

  12. Time analysis for optimization of radiology workflow in conventional radiology during RIS-PACS-integration

    Science.gov (United States)

    Falkensammer, Peter; Soegner, Peter I.; zur Nedden, Dieter

    2002-05-01

    The integration of RIS-PACS systems in radiology units are intended to reduce time consumption in radiology workflow and thus to increase radiologist productivity. Along with the RIS-PACS integration at the University Hospital Innsbruck we analyzed workflow from patient admission to release of final reports before implementation. The follow up study after six months of the implementation is currently in work. In this study we compared chest to skeletal x-ray examinations in 969 patients before the implementation. Drawing the admission-to-release-of-final-report period showed a two-peak diagram with the first peak corresponding to a release of final results on the same day and the second peak to a release on the following day. In the chest x-ray group, 57% were released the same day (mean value 4:02 hours) and 43% the next day (mean value 21:47 hours). Looking at the skeletal x-rays 40% were released the same day (mean value 3:58 hours) and 60% were released the next day (mean value 21:05 hours). Summarizing the results we should say, that the average chest x-ray requires less time than an skeletal x-ray, due to the fact that a greater percentage of reports is released the same day. The most important result is, that the most time consuming workstep is the exchange of data media between radiologist and secretary with at least 5 hours.

  13. The Scrap Tire Problem: A Preliminary Economic Analysis (1985)

    Science.gov (United States)

    The purpose of the study was to conduct a preliminary economic analysis of the social benefits of EPA action to require more appropriate disposal of scrap tires versus the social costs of such an action.

  14. Preliminary site characterization radiological monitoring plan for the Nevada Nuclear Waste Storage Investigations Project, Yucca Mountain Site

    International Nuclear Information System (INIS)

    1987-03-01

    The activities described in this plan occur in the early phases of site characterization. This document presents the Preliminary Site Characterization Radiological Monitoring Plan (PSCRMP) for collecting and evaluating data in support of the NNWSI Project. The PSCRMP defines and identifies control procedures for the monitoring activities. The PSCRMP activity will utilize integrating radon monitoring devices, a continuous radon monitor, and a particulate air sampler. These instruments will be used to establish the baseline radioactivity and/or radioactivity released due to early site characterization activities. The sections that follow provide a general project description, the specifics of the monitoring program, and the practices that will be employed to ensure the validity of the collected data by integrating quality assurance into all activities. Section 2 of this document describes the regulatory base of this document. Section 3 describes the site characterization activities which may lead to release of radioactivity. Section 4 provides a description of the potential sources of radioactivity that site characterization could generate. Section 5 summarizes the sampling and monitoring methodology, which will be used to monitor the potential sources of radioactivity. The network of sampling and monitoring equipment is described in Section 6, and Section 7 summarizes the systems operation activities. The data reporting activities are described in Section 8. Finally, a description of the Quality Assurance (QA) and Quality Control (QC) activities is provided in Section 9. Appendix A contains a summary of the procedures to be used in this program, and Appendix B contains technical specification on equipment and services. 20 refs., 11 figs., 2 tabs

  15. Preliminary study on the radiological and physicochemical quality of the Umgeni Water catchments and drinking water sources in KwaZulu-Natal, South Africa

    International Nuclear Information System (INIS)

    Manickum, T.; John, W.; Terry, S.; Hodgson, K.

    2014-01-01

    Raw and potable water sample sources, from the Umgeni Water catchment areas (rivers, dams, boreholes) in central KwaZulu-Natal (South Africa), were screened for Uranium concentration and alpha and beta radioactivity. Test methods used were gas flow proportional counting for alpha-beta radioactivity, and kinetic phosphorescence analysis (KPA), for Uranium. The uranium levels (median = 0.525 μg/L, range = <0.050–5.010) were well below the international World Health Organization (WHO) (2011) guideline for drinking-water quality (≤15 μg/L). The corresponding alpha and beta radioactivity was ≤0.5 Bq/L (median = 0.084, Interquartile Range (IR) = 0.038, range = 0.018–0.094), and ≤1.0 Bq/L (median = 0.114, IR = 0.096, range = 0.024–0.734), respectively, in compliance with the international WHO limits. For uranium radionuclide, the average dose level, at uranium level of ±0.525 μg/L, was 0.06 μSv/a, which complies with the WHO reference dose level for drinking water (<0.1 mSv/a). There was a distinct trend of cluster of relatively higher Uranium levels of some sources that were found to be associated with the geology/geography and groundwater sources. Overall, the radiological water quality classification, with respect to WHO, is “Blue” – ideal; additional physicochemical analyses indicated good water quality. The analytical test methods employed were found to be suitable for preliminary screening for potential radioactive “hot spots”. The observed Uranium levels, and the alpha/beta radioactivity, indicate contribution largely from Naturally Occurring Radioactive Material (NORM), with no significant health risk to humans, or to the environment. - Highlights: • Radiological and physicochemical quality of raw and drinking water sources. • Suitability of kinetic phosphorescence analysis for Uranium analysis of water. • Suitability of gas flow proportional counting for determining radioactivity of water. • The Effective

  16. Radiological assessment. A textbook on environmental dose analysis

    International Nuclear Information System (INIS)

    Till, J.E.; Meyer, H.R.

    1983-09-01

    Radiological assessment is the quantitative process of estimating the consequences to humans resulting from the release of radionuclides to the biosphere. It is a multidisciplinary subject requiring the expertise of a number of individuals in order to predict source terms, describe environmental transport, calculate internal and external dose, and extrapolate dose to health effects. Up to this time there has been available no comprehensive book describing, on a uniform and comprehensive level, the techniques and models used in radiological assessment. Radiological Assessment is based on material presented at the 1980 Health Physics Society Summer School held in Seattle, Washington. The material has been expanded and edited to make it comprehensive in scope and useful as a text. Topics covered include (1) source terms for nuclear facilities and Medical and Industrial sites; (2) transport of radionuclides in the atmosphere; (3) transport of radionuclides in surface waters; (4) transport of radionuclides in groundwater; (5) terrestrial and aquatic food chain pathways; (6) reference man; a system for internal dose calculations; (7) internal dosimetry; (8) external dosimetry; (9) models for special-case radionuclides; (10) calculation of health effects in irradiated populations; (11) evaluation of uncertainties in environmental radiological assessment models; (12) regulatory standards for environmental releases of radionuclides; (13) development of computer codes for radiological assessment; and (14) assessment of accidental releases of radionuclides

  17. Radiological assessment. A textbook on environmental dose analysis

    Energy Technology Data Exchange (ETDEWEB)

    Till, J.E.; Meyer, H.R. (eds.)

    1983-09-01

    Radiological assessment is the quantitative process of estimating the consequences to humans resulting from the release of radionuclides to the biosphere. It is a multidisciplinary subject requiring the expertise of a number of individuals in order to predict source terms, describe environmental transport, calculate internal and external dose, and extrapolate dose to health effects. Up to this time there has been available no comprehensive book describing, on a uniform and comprehensive level, the techniques and models used in radiological assessment. Radiological Assessment is based on material presented at the 1980 Health Physics Society Summer School held in Seattle, Washington. The material has been expanded and edited to make it comprehensive in scope and useful as a text. Topics covered include (1) source terms for nuclear facilities and Medical and Industrial sites; (2) transport of radionuclides in the atmosphere; (3) transport of radionuclides in surface waters; (4) transport of radionuclides in groundwater; (5) terrestrial and aquatic food chain pathways; (6) reference man; a system for internal dose calculations; (7) internal dosimetry; (8) external dosimetry; (9) models for special-case radionuclides; (10) calculation of health effects in irradiated populations; (11) evaluation of uncertainties in environmental radiological assessment models; (12) regulatory standards for environmental releases of radionuclides; (13) development of computer codes for radiological assessment; and (14) assessment of accidental releases of radionuclides.

  18. Needle stick injury in a radiology department: a decade analysis

    International Nuclear Information System (INIS)

    Sayani, R.; Rajani, A.

    2012-01-01

    Objectives: To determine the frequency of needle stick injury in health care workers of radiology department. Study type, settings and duration: Cross sectional, observational study conducted at the Radiology department of Aga Khan University hospital from January 2000 to May 2010. Subject and Methods: All self-reported needle stick injuries data of Health care workers of radiology department was recorded. The personnel involved (Radiologist, resident, radiographer, nurses etc), area of working and the causes of injury were identified including the procedural or post procedural details. Patient's status of hepatitis or blood borne infection was also noted. Data was recorded and analyzed in Excel worksheet. Results: A total of 55 health workers reported needle stick injuries at all sections of radiology departments with maximum number needle stick injuries at general radiography, fluoroscopy and IVP section. Radiographers and radiology residents received the maximum number of injuries. Major cause of injury was cannulation however, many injuries occurred during disposing or handling of bin. In majority of cases the patients were not infected with any known blood borne infections. Conclusions: Doctors and nurses get needle-stick injuries while carrying out clinical procedures, while, ancillary staff get infected post procedure during disposal of garbage. Policy message: Good occupational health and safety practices must be promoted to all staff. Safer disposal of needles is an important area where practice and procedure needs to be carefully reviewed. It is necessary to undertake a risk assessment, to offer counseling and Post Exposure Prophylaxis and treatment where necessary. (author)

  19. Original Article PRELIMINARY BIOAUTOGRAPHIC ANALYSIS OF ...

    African Journals Online (AJOL)

    Sierra Leone 2Department of Pharmaceutical Chemistry, Faculty of Pharmacy, ... the seeds are used in the treatment of skin infections. ... Screening with DPPH showed prominent antioxidant spots on silica at Rf 0.8, 0.5, 0.4 .... underpins conditions like rheumatoid arthritis, ..... As a follow-up to the preliminary TLC studies.

  20. Standarized radiological hazard analysis for a broad based operational safety program

    International Nuclear Information System (INIS)

    Wadman, W.W. III; Andrews, L.L.

    1992-01-01

    The Radiological hazard Analysis (RHA) Manual provides a methodology and detailed guidance for systematic analysis of radiological hazards over a broad spectrum of program functions, housed in a wide variety of facilities. Radiological programs at LANL include: research and experimentation; routine materials operations; production; non-destructive examination or testing; isotope and machine produced radiations; chemistry; and metallurgy. The RHA permits uniform evaluation of hazard types over a range of several orders of magnitude of hazard severity. The results are used to estimate risk, evaluate types and level or resource allocations, identify deficiencies, and plan corrective actions for safe working environments. 2 refs

  1. Standardized radiological hazard analysis for a broad based operational safety program

    International Nuclear Information System (INIS)

    Wadman, W. III; Andrews, L.

    1992-01-01

    The Radiological Hazard Analysis (RHA) Manual provides a methodology and detailed guidance for systematic analysis of radiological hazards over a broad spectrum of program functions, housed in a wide variety of facilities. Radiological programs at LANL include: research and experimentation routine materials operations; production; non-destructive examination or testing; isotope and machine produced radiations; chemistry; and metallurgy. The RHA permits uniform evaluation of hazard types over a range of several orders of magnitude of hazard severity. The results are used to estimate risk, evaluate types and level of resource allocations, identify deficiencies, and plan corrective actions for safe working environments. (author)

  2. Radiological consequence analysis with HEU and LEU fuels

    Energy Technology Data Exchange (ETDEWEB)

    Woodruff, W.L.; Warinner, D.K.; Matos, J.E.

    1984-01-01

    A model for estimating the radiological consequences from a hypothetical accident in HEU and LEU fueled research and test reactors is presented. Simple hand calculations based on fission product yield table inventories and non-site specific dispersion data may be adequate in many cases. However, more detailed inventories and site specific data on meteorological conditions and release rates and heights can result in substantial reductions in the dose estimates. LEU fuel gives essentially the same doses as HEU fuel. The plutonium buildup in the LEU fuel does not significantly increase the radiological consequences. The dose to the thyroid is the limiting dose. 10 references, 3 figures, 7 tables.

  3. Radiological consequence analysis with HEU and LEU fuels

    International Nuclear Information System (INIS)

    Woodruff, W.L.; Warinner, D.K.; Matos, J.E.

    1984-01-01

    A model for estimating the radiological consequences from a hypothetical accident in HEU and LEU fueled research and test reactors is presented. Simple hand calculations based on fission product yield table inventories and non-site specific dispersion data may be adequate in many cases. However, more detailed inventories and site specific data on meteorological conditions and release rates and heights can result in substantial reductions in the dose estimates. LEU fuel gives essentially the same doses as HEU fuel. The plutonium buildup in the LEU fuel does not significantly increase the radiological consequences. The dose to the thyroid is the limiting dose. 10 references, 3 figures, 7 tables

  4. A radiological consequence analysis with HEU and LEU fuels

    International Nuclear Information System (INIS)

    Woodruff, W.L.; Warinner, D.K.; Matos, J.E.

    1985-01-01

    A model for estimating the radiological consequences from a hypothetical accident in HEU and LEU fueled research and test reactors is presented. Simple hand calculations based on fission product yield table inventories and nonsite specific dispersion data may be adequate in many cases. However, more detailed inventories and site specific data on meteorological conditions and release rates and heights can result in substantial reductions in the dose estimates. LEU fuel gives essentially the same doses as HEU fuel. The plutonium buildup in the LEU fuel does not significantly increase the radiological consequences. The dose to the thyroid is the limiting dose. (author)

  5. Radiological Consequences Analysis for Abnormal Condition on NPPs 1000 MWe by Using Radcon Model

    International Nuclear Information System (INIS)

    Pande Mande Udiyani; Sri Kuntjoro

    2009-01-01

    The operation of NPPs (Nuclear Power Plants) in Indonesia to anticipates rare of energy will generate various challenges, especially about NPPs safety. So installation organizer of nuclear must provide scientific argument to safety NPPs, one of them is by providing document of safety analysis. Calculation of radiological consequences after abnormal condition applies on generic PWR-1000 power reactor. Calculation is done by using program package RadCon (Radiological Consequences Model), with postulate condition is based on DBA (Design Basis Accident). Calculation of dispersion of radionuclide concentration is using PC-COSYMA as input data for RadCon. Simulation for radiological consequences analysis uses by site data sample. Analysis result shows that maximum receiving of internal - externals radiological consequence for short term and long-term below 1 km radius area is below the limit acceptably effective dose for a member of the public as a result of an accident which should not exceed 5 mSv (ICRP 1990). (author)

  6. Life cycle analysis in preliminary design stages

    OpenAIRE

    Agudelo , Lina-Maria; Mejía-Gutiérrez , Ricardo; Nadeau , Jean-Pierre; PAILHES , Jérôme

    2014-01-01

    International audience; In a design process the product is decomposed into systems along the disciplinary lines. Each stage has its own goals and constraints that must be satisfied and has control over a subset of design variables that describe the overall system. When using different tools to initiate a product life cycle, including the environment and impacts, its noticeable that there is a gap in tools that linked the stages of preliminary design and the stages of materialization. Differen...

  7. Gender Trends in Radiology Authorship: A 35-Year Analysis.

    Science.gov (United States)

    Piper, Crystal L; Scheel, John R; Lee, Christoph I; Forman, Howard P

    2016-01-01

    The purpose of this study was to describe trends over time in female authorship in the radiology literature and to investigate the tendency of female first authors to publish with female senior authors. Data on the gender of academic physician authors based in the United States for all major articles published in three general radiology journals--Radiology, AJR, and Academic Radiology--were collected and analyzed for the years 1978, 1988, 1998, 2008, and 2013. Multivariate logistic regression was used to identify significant trends over time, and a chi-square test of independence was performed to determine significant relations between the genders of first and senior authors. The gender of 4182 of 4217 (99.17%) authors with MD degrees was determined. The proportion of original research articles published by women as first authors increased from 8.33% in 1978 to 32.35% in 2013 (p < 0.001). The proportion of original research articles with women as senior authors increased from 6.75% in 1978 to 21.90% in 2013 (p < 0.001). Female first and senior authorship increased significantly over time (first author, p < 0.001; senior author, p < 0.001). There was a statistically significant relation between the genders of first and senior authors of original research articles and guest editorials (p < 0.001). Over 35 years, there was a statistically significant upward linear trend of female physician participation in authorship of academic radiology literature. Female first authors were more likely to publish with female senior authors.

  8. Analysis of radioactive contaminations and radiological hazard in Poland after the Chernobyl reactor accident

    International Nuclear Information System (INIS)

    Zarnowiecki, K.

    1988-01-01

    It is a report on radiological impact in Poland following the Chernobyl reactor accident prepared in the Central Laboratory for Radiological Protection. The results of measurement and its analysis are presented. Isotopic composition of the contamined air and the concentration of radionuclides are determined. The trajectories of the airborne radioactive material movement from Chernobyl to Poland at the last days of April 1986 are presented. Assessment of the radiological risk of the population is done. 38 refs., 20 figs., 11 tabs. (M.F.W.)

  9. Review of Preliminary Analysis Techniques for Tension Structures.

    Science.gov (United States)

    1984-02-01

    however,a linear dinamic analysis can be conducted for purposes of preliminary design, relative to the static configuration. It is noted that the amount of...16 Chapter 3. PRELIMINARY DESIGN OF TENSION STRUCTURES . . .. .. .. .... 22 S.3.1 Cable Systems . . . . . . . . . . . . .. .. .. .... 23...3.1.1 Singly-Connected Segments. .. .... ... 24 3.1.2 Multiply-Connected Segments . . .. .. .. .. 27 3.1.3 Linearized Dynamics of Cable Systems . . . . 29

  10. Radiological analysis of polyostotic fibrous dysplasia in skeletal system

    International Nuclear Information System (INIS)

    Shin, Ma Rie; Kim, Jin Sik; Kim, Han Suk; Park, Soo Soung

    1984-01-01

    Over a period of recent 3 years, the 5 cases of polyostotic fibrous dysplasia were proven histologically at National Medical Center, and they were evaluated and analyzed radiologically and clinically. The results were as follows: 1. The age of 5 patients ranged from 12 to 21. 2. In general, clinical symptoms of these patients were pain of affected sites and swelling , fracture, walking disturbance of lower extremities. 3. The order of frequent site of polyostotic fibrous dysplasia was skull (4 cases), femur (3 cases), maxilla (2 case), humerus, tibia, rib, radius, metacarpal bone and phalanx. 4. The characteristic radiological findings of polyostotic fibrous dysplasia were multicystic lesions with ground glass appearance, osteosclerosis, cortical thinning and pathologic fracture and deformity of long bones. Particularly, in the extremities, multicystic radiolucencies, groud glass appearance, shepherd's crook and coxa vara deformities were noticed, and in the skull and maxilla, sclerotic changes were principally demonstrated.

  11. Common fluoroscopic studies in radiology : conduct and analysis method

    International Nuclear Information System (INIS)

    Valverde Sanchez, Allan

    2011-01-01

    A countless number of radiological procedures, that have involved the use of fluoroscopy and contrast media of different indole, have been carried out in all radiology services and medical images of Costa Rica for the diagnosis of diseases or conditions, in both adults and in children. Fluoroscopic studies, often called special or contrast studies, have had particular conditions for its realization. Some from the medical point of view: adequate training in the technical and cognitive development when evaluating the images to not miss important details. Other by the patient: adequate preparation to achieve the best images for optimal diagnosis. For example, adequate bowel preparation is essential for a barium enema, to cooperation by the patient to meet specific indications that the physician dictates when swallowing postures or just when you are prompted. Criteria have been met and unified for contrast studies in different hospitals and clinics. The indications, contra, method, technique of procedure, points to remember, number of images or projections minimum required in the interpretation of contrast studies, as well as a report template of standard and ideal study are presented in a simple, systematic and logical. The manual is intended for residents and attending physicians specialists in radiology and medical imaging including contrast studies more common. Spaces are promoted with current technology studies to set aside more complicated and less sophisticated as have been the fluoroscopic studies; however, in the national reality, access to computerized tomography and magnetic resonance imaging is not as easy. Radiological studies with fluoroscopy performed by trained staff led the treating physician to make sound decisions based on studies relatively simple and easy to do. The tests with the use of fluoroscopic have been named: the esophagogram, gastroduodenal series, gastro intestinal transit, the hysterosalpingography, the cystography and the

  12. A preliminary assessment of the radiological implications of commercial utilization of natural gas from a nuclearly stimulated well

    Energy Technology Data Exchange (ETDEWEB)

    Jacobs, D G; Struxness, E G [Health Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States); Bowman, C R [El Paso Natural Gas Company, El Paso, TX (United States)

    1970-05-01

    Widespread utilization of nuclear explosives, in conjunction with the natural gas industry, can result in radiation exposure of sizable population groups. It is prudent to make realistic assessments of such potential radiation exposures before they occur and, unless the expected exposures are clearly insignificant, to consider these exposures in evaluating the net benefit of this particular use of nuclear energy. All pertinent facts relating to such assessments should be made public and presented in such a way that those who are to assume the risks, if any, can make a reasonable judgment as to whether the risks are acceptable. Radioactivity in natural gas from the Gasbuggy cavity has been analyzed prior to and during flaring operations. None of this gas has entered the collection and distribution system, but a theoretical analysis has been made of the hypothetical impact on members of the public that would have occurred if the gas had been introduced into the commercial stream. Dose equivalents have been estimated for both workers and consumers. In this analysis, Gasbuggy gas has been traced through a real gas-collection system and processing plant, as represented by the present situation existing in the San Juan Production Division, El Paso Natural Gas Company. In addition, a number of considerations are presented which would apply to radiation exposure in metropolitan areas. Results of this analysis for the Gasbuggy well indicate hypothetical dose equivalents to various population groups to be well within the annual dose limits suggested by the International Commission on Radiological Protection. Projection to a steady-state situation involving extensive natural gas production from many producing wells also resulted in hypothetical dose equivalents within the annual dose limits. Simple extrapolation of the results from this analysis to potential exposures resulting from nuclear stimulation of other gas reservoirs cannot be made on a direct basis, but this method

  13. A preliminary assessment of the radiological implications of commercial utilization of natural gas from a nuclearly stimulated well

    International Nuclear Information System (INIS)

    Jacobs, D.G.; Struxness, E.G.; Bowman, C.R.

    1970-01-01

    Widespread utilization of nuclear explosives, in conjunction with the natural gas industry, can result in radiation exposure of sizable population groups. It is prudent to make realistic assessments of such potential radiation exposures before they occur and, unless the expected exposures are clearly insignificant, to consider these exposures in evaluating the net benefit of this particular use of nuclear energy. All pertinent facts relating to such assessments should be made public and presented in such a way that those who are to assume the risks, if any, can make a reasonable judgment as to whether the risks are acceptable. Radioactivity in natural gas from the Gasbuggy cavity has been analyzed prior to and during flaring operations. None of this gas has entered the collection and distribution system, but a theoretical analysis has been made of the hypothetical impact on members of the public that would have occurred if the gas had been introduced into the commercial stream. Dose equivalents have been estimated for both workers and consumers. In this analysis, Gasbuggy gas has been traced through a real gas-collection system and processing plant, as represented by the present situation existing in the San Juan Production Division, El Paso Natural Gas Company. In addition, a number of considerations are presented which would apply to radiation exposure in metropolitan areas. Results of this analysis for the Gasbuggy well indicate hypothetical dose equivalents to various population groups to be well within the annual dose limits suggested by the International Commission on Radiological Protection. Projection to a steady-state situation involving extensive natural gas production from many producing wells also resulted in hypothetical dose equivalents within the annual dose limits. Simple extrapolation of the results from this analysis to potential exposures resulting from nuclear stimulation of other gas reservoirs cannot be made on a direct basis, but this method

  14. Establishment and preliminary application of the interactive tele-radiologic conference system based on virtual private network

    International Nuclear Information System (INIS)

    Wang Xuejian; Hu Jian; Wang Kang; Yu Hui; Luo Min; Lei Wenyong

    2005-01-01

    Objective: To investigate the establishment and characteristics of the interactive tele-radiological system (IATRS). Methods: Local area network (LAN) of local hospitals with firewall and ADSL Modem was connected into internet, then connected into the Virtual Private Network (VPN) server of the affiliated hospital of Guiyang Medical College (GMCAH) through anti-firewall of GMCAH. The VPN tunnel was acquired and LAN of local hospitals was connected into the PACS server of GMCAH, resulting in sharing of radiological data by both the GMCAH and local hospitals. Results: Radiological data from local hospitals could be transmitted by the PACS server of GMCAH safety and rapidly. The IATRS could provide high-quality images with high-speed, and with ease to perform. Conclusion: IATRS is useful and reliable for transmitting radiological data between remote places. (authors)

  15. Radiological impacts analysis with use of new endpoint as complementary safety indicators

    International Nuclear Information System (INIS)

    Peralta Vital, J.L.; Gil Castillo, R.; Fleitas Estevez, G.G.; Olivera Acosta, J.

    2015-01-01

    The paper shows the new safety indicators on risk assessment (safety assessment) to radioactive waste environmental management implementation (concentrations and fluxes of naturally occurring radioactive materials (NORM)). The endpoint obtained, allow the best analysis of the radiological impact associated to radioactive waste isolation system. The common safety indicators for safety assessment purpose, dose and risk, are very time dependent, increasing the uncertainties in the results for long term assessment. The complementary and new proposed endpoints are more stable and they are not affected by changes in the critical group, pathways, etc. The NORM values on facility site were obtained as result of national surveys, the natural concentrations of U, Ra, Th, K has been associated with the variation of the lithologies in 3 geographical areas of the Country (Occidental, Central and Oriental). The results obtained are related with the safety assessment topics and allowed to apply the new complementary safety indicators, by comparisons between the natural concentrations and fluxes on site and its calculated values for the conceptual repository design. In order to normalize the concentration results, the analysis was realized adopting the criteria of the Repository Equivalent Rock Volume (RERV). The preliminary comparison showed that the calculated concentrations and fluxes in the Cuban conceptual radioactive waste repository are not higher than the natural values in the host rock. According to the application of new safety indicators, the reference disposal facility does not increase the natural activity concentration and fluxes in the environment. In order to implement these new safety indicator it has been used the current 226 Ra inventory of the Repository and the 226 Ra as natural concentration on the site. (authors)

  16. Comprehensive analysis of a Radiology Operations Management computer system.

    Science.gov (United States)

    Arenson, R L; London, J W

    1979-11-01

    The Radiology Operations Management computer system at the Hospital of the University of Pennsylvania is discussed. The scheduling and file room modules are based on the system at Massachusetts General Hospital. Patient delays are indicated by the patient tracking module. A reporting module allows CRT/keyboard entry by transcriptionists, entry of standard reports by radiologists using bar code labels, and entry by radiologists using a specialty designed diagnostic reporting terminal. Time-flow analyses demonstrate a significant improvement in scheduling, patient waiting, retrieval of radiographs, and report delivery. Recovery of previously lost billing contributes to the proved cost effectiveness of this system.

  17. Analysis of a radiation incident with intraoral dental radiological equipment

    International Nuclear Information System (INIS)

    Malone, J.F.

    1996-01-01

    A case is described involving a serious incident with dental radiological equipment, containing many lessons that may be applied to the preparation of other cases. The description includes an account of the incident, the circumstances surrounding it, the dosimetry, risk estimates and the medical consequences of the incident. In addition, some aspects of the associated legal proceedings are reviewed and assessed. As a result of the incident described, a number of conclusions are drawn with respect to important practices in ensuring the safety of installations and the value of evidence brought forward by expert witnesses. (author)

  18. Preliminary ATWS analysis for the IRIS PRA

    International Nuclear Information System (INIS)

    Maddalena Barra; Marco S Ghisu; David J Finnicum; Luca Oriani

    2005-01-01

    Full text of publication follows: The pressurized light water cooled, medium power (1000 MWt) IRIS (International Reactor Innovative and Secure) has been under development for four years by an international consortium of over 21 organizations from ten countries. The plant conceptual design was completed in 2001 and the preliminary design is nearing completion. The pre-application licensing process with NRC started in October, 2002. IRIS has been primarily focused on establishing a design with innovative safety characteristics. The first line of defense in IRIS is to eliminate event initiators that could potentially lead to core damage. In IRIS, this concept is implemented through the 'safety by design' approach, which allows to minimize the number and complexity of the safety systems and required operator actions. The end result is a design with significantly reduced complexity and improved operability, and extensive plant simplifications to enhance construction. To support the optimization of the plant design and confirm the effectiveness of the safety by design approach in mitigating or eliminating events and thus providing a significant reduction in the probability of severe accidents, the PRA is being used as an integral part of the design process. A preliminary but extensive Level 1 PRA model has been developed to support the pre-application licensing of the IRIS design. As a result of the Preliminary IRIS PRA, an optimization of the design from a reliability point of view was completed, and an extremely low (about 1.2 E -8 ) core damage frequency (CDF) was assessed to confirm the impact of the safety by design approach. This first assessment is a result of a PRA model including internal initiating events. During this assessment, several assumptions were necessary to complete the CDF evaluation. In particular Anticipated Transients Without Scram (ATWS) were not included in this initial assessment, because their contribution to core damage frequency was assumed

  19. Preliminary safety design analysis of KALIMER

    Energy Technology Data Exchange (ETDEWEB)

    Suk, Soo Dong; Kwon, Y. M.; Kim, K. D. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-03-01

    The national long-term R and D program updated in 1997 requires Korea Atomic Energy Research Institute(KAERI) to complete by the year 2006 the basic design of Korea Advanced Liquid Metal Reactor (KALIMER), along with supporting R and D work, with the capability of resolving the issue of spent fuel storage as well as with significantly enhanced safety. KALIMER is a 150 MWe pool-type sodium cooled prototype reactor that uses metallic fuel. The conceptual design is currently under way to establish a self consistent design meeting a set of the major safety design requirements for accident prevention. Some of current emphasis include those for inherent and passive means of negative reactivity insertion and decay heat removal, high shutdown reliability, prevention of and protection from sodium chemical reaction, and high seismic margin, among others. All of these requirements affect the reactor design significantly and involve supporting R and D programs of substance. This document first introduces a set of safety design requirements and accident evaluation criteria established for the conceptual design of KALIMER and then summarizes some of the preliminary results of engineering and design analyses performed for the safety of KALIMER. 19 refs., 19 figs., 6 tabs. (Author)

  20. Preliminary shielding analysis of VHTR reactors

    International Nuclear Information System (INIS)

    Flaspoehler, Timothy M.; Petrovic, Bojan

    2011-01-01

    Over the last 20 years a number of methods have been established for automated variance reduction in Monte Carlo shielding simulations. Hybrid methods rely on deterministic adjoint and/or forward calculations to generate these parameters. In the present study, we use the FWCADIS method implemented in MAVRIC sequence of the SCALE6 package to perform preliminary shielding analyses of a VHTR reactor. MAVRIC has been successfully used by a number of researchers for a range of shielding applications, including modeling of LWRs, spent fuel storage, radiation field throughout a nuclear power plant, study of irradiation facilities, and others. However, experience in using MAVRIC for shielding studies of VHTRs is more limited. Thus, the objective of this work is to contribute toward validating MAVRIC for such applications, and identify areas for potential improvement. A simplified model of a prismatic VHTR has been devised, based on general features of the 600 MWt reactor considered as one of the NGNP options. Fuel elements have been homogenized, and the core region is represented as an annulus. However, the overall mix of materials and the relatively large dimensions of the spatial domain challenging the shielding simulations have been preserved. Simulations are performed to evaluate fast neutron fluence, dpa, and other parameters of interest at relevant positions. The paper will investigate and discuss both the effectiveness of the automated variance reduction, as well as applicability of physics model from the standpoint of specific VHTR features. (author)

  1. Paediatric radiology and scientific contributions to radiation dose at the meeting of the German Radiological Society-An analysis of an 11-year period

    International Nuclear Information System (INIS)

    Heyer, Christoph M.; Lemburg, Stefan P.; Peters, Soeren A.

    2010-01-01

    Aim: Evaluation of the emphasis on themes pertaining to paediatric radiology and radiation dose at the Meeting of the German Radiological Society from 1998 to 2008 in comparison to international data. Materials and methods: Retrospective analysis of 9440 abstracts with documentation of type of contribution, imaging modality, and examined body region. Abstracts primarily dealing with paediatric radiology and those stating radiation dose were documented. Results were compared with a Pubmed query. Results: 448 contributions in paediatric radiology were presented corresponding to 5% of all abstracts with an increase from 5 (1998) to 7% (2008). The proportion of prospective studies of all congress contributions was 10%, whereas in paediatric radiology, the share of prospective studies was 6%. From 1998 to 2008, the share of MRI fell from 48 to 38%, while CT contributions rose from 30 to 34%. Within paediatric radiology, the proportion of CT rose from 23 to 29%, while MRI and ultrasound fell from 63 to 48% and 35 to 19%, respectively. The share of abstracts dealing with radiation dose rose from 7 to 10% while that primarily pertaining to dose reduction grew from 2 to 4%. Of all abstracts concerning CT, 15% touched on radiation dose, whereas 6% primarily dealt with dose reduction. Among all abstracts dealing with paediatric radiology, 20 and 6% mentioned radiation dose and dose reduction, respectively. In the subgroup of paediatric radiology CT abstracts, radiation dose and dose reduction were mentioned in 34 and 16%, respectively. An online query produced 137,791 publications on CT, of whose abstracts 3% mentioned radiation dose and 0.5% mentioned dose reduction. 11% of all CT publications dealt with paediatric populations and 2% of these publications examined questions of radiation dose. Conclusions: In the last 11 years the Meeting of the German Radiological Society has presented a growing number of contributions pertaining to paediatric radiology. CT has shown the

  2. Preliminary analysis of B. E. C. I

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, H; Sato, S [Waseda Univ., Tokyo (Japan). Science and Engineering Research Lab.; Saito, T; Noma, M; Matsubayashi, T

    1974-10-01

    An emulsion chamber (B.E.C.I.) with a generating layer, mounted on a baloon, was flown as preliminary experiment in May 1973. The object of this experiment was (1) the observation of high energy cosmic ray, (2) study of ultra-high energy multiple generation phenomenon, and (3) study of ultra-high energy heavy ion nuclear reaction. The emulsion chamber comprises three portions. Upper portion is 130 sheets arranged vertically at 3 mm intervals, each sheet is a 1,500 ..mu..m methacrylic base coated on one side with 200 ..mu..m emulsion. Middle portion comprises horizontally arranged 800 ..mu..m methacrylic bases coated on both sides with 50 ..mu..m emulsion, and a 1 mm methacrylic sheet is inserted every five bases. Lower portion comprises first five layers of the sandwich of 1 mm lead sheet and 800 ..mu..m methacrylic base coated on both sides with 50 ..mu..m emulsion and second ten layers of the sandwich of 2 mm lead sheet, 800 ..mu..m methacrylic base coated on one side with 50 ..mu..m emulsion, and X-ray film of N type. The cascade having energy of Esub(o)>400 GeV as the scanning efficiency of lower E.C.C., the events having incidental energy of Esub(o)>3TeV among the jets occured in lower E.C.C., and the events having incidental energy of Esub(o)>10TeV among the jets occured in generating layer have been observed. Angle distribution of the secondary charged particles of jets produced in the generating layer can be obtained accurately.

  3. Stockholm Safety Conference. Analysis of the sessions on radiological protection, licensing and risk assessment

    International Nuclear Information System (INIS)

    Gea, A.

    1981-01-01

    A summary of the sessions on radiological protection, licensing and risk assessment in the safety conference of Stockholm is presented. It is considered the new point of view of the nuclear safety, probabilistic analysis, components failures probability and accident analysis. They are included conclusions applicable in many cases to development countries. (author)

  4. Practical Recommendations for the Preliminary Design Analysis of ...

    African Journals Online (AJOL)

    Interior-to-exterior shear ratios for equal and unequal bay frames, as well as column inflection points were obtained to serve as practical aids for preliminary analysis/design of fixed-feet multistory sway frames. Equal and unequal bay five story frames were analysed to show the validity of the recommended design ...

  5. Yucca Mountain transportation routes: Preliminary characterization and risk analysis

    International Nuclear Information System (INIS)

    Souleyrette, R.R. II; Sathisan, S.K.; di Bartolo, R.

    1991-01-01

    This report presents appendices related to the preliminary assessment and risk analysis for high-level radioactive waste transportation routes to the proposed Yucca Mountain Project repository. Information includes data on population density, traffic volume, ecologically sensitive areas, and accident history

  6. Preliminary analysis of patent trends for magnetic fusion technology

    International Nuclear Information System (INIS)

    Levine, L.O.; Ashton, W.B.; Campbell, R.S.

    1984-02-01

    This study presents a preliminary analysis of development trends in magnetic fusion technology based on data from US patents. The research is limited to identification and description of general patent activity and ownership characteristics for 373 patents. The results suggest that more detailed studies of fusion patents could provide useful R and D planning information

  7. Licensing support system preliminary needs analysis: Volume 1

    International Nuclear Information System (INIS)

    1989-01-01

    This Preliminary Needs Analysis, together with the Preliminary Data Scope Analysis (next in this series of reports), is a first effort under the LSS Design and Implementation Contract toward developing a sound requirements foundation for subsequent design work. Further refinements must be made before requirements can be specified in sufficient detail to provide a basis for suitably specific system specifications. This preliminary analysis of the LSS requirements has been divided into a ''needs'' and a ''data scope'' portion only for project management and scheduling reasons. The Preliminary Data Scope Analysis will address all issues concerning the content and size of the LSS data base; providing the requirements basis for data acquisition, cataloging and storage sizing specifications. This report addresses all other requirements for the LSS. The LSS consists of both computer subsystems and non-computer archives. This study addresses only the computer subsystems, focusing on the Access Subsystems. After providing background on previous LSS-related work, this report summarizes the findings from previous examinations of needs and describes a number of other requirements that have an impact on the LSS. The results of interviews conducted for this report are then described and analyzed. The final section of the report brings all of the key findings together and describes how these needs analyses will continue to be refined and utilized in on-going design activities. 14 refs., 2 figs., 1 tab

  8. Preliminary thermal and stress analysis of the SINQ window

    International Nuclear Information System (INIS)

    Heidenreich, G.

    1991-01-01

    Preliminary results of a finite element analysis for the SINQ proton beam window are presented. Temperatures and stresses are calculated in an axisymmetric model. As a result of these calculations, the H 2 O-cooled window (safety window) could be redesigned in such a way that plastic deformation resulting from excessive stress in some areas is avoided. (author)

  9. Preliminary Integrated Safety Analysis Status Report

    International Nuclear Information System (INIS)

    Gwyn, D.

    2001-01-01

    This report provides the status of the potential Monitored Geologic Repository (MGR) Integrated Safety Analysis (EA) by identifying the initial work scope scheduled for completion during the ISA development period, the schedules associated with the tasks identified, safety analysis issues encountered, and a summary of accomplishments during the reporting period. This status covers the period from October 1, 2000 through March 30, 2001

  10. Analysis of factors correlating with medical radiological examination frequencies

    International Nuclear Information System (INIS)

    Jahnen, A.; Jaervinen, H.; Bly, R.; Olerud, H.; Vassilieva, J.; Vogiatzi, S.; Shannoun, F.

    2015-01-01

    The European Commission (EC) funded project Dose Datamed 2 (DDM2) had two objectives: to collect available data on patient doses from the radiodiagnostic procedures (X-ray and nuclear medicine) in Europe, and to facilitate the implementation of the Radiation Protection 154 Guidelines (RP154). Besides the collection of frequency and dose data, two questionnaires were issued to gather information about medical radiological imaging. This article analyses a possible correlation between the collected frequency data, selected variables from the results of the detailed questionnaire and national economic data. Based on a 35 countries dataset, there is no correlation between the gross domestic product (GDP) and the total number of X-ray examinations in a country. However, there is a significant correlation ( p < 0.01) between the GDP and the overall CT examination frequency. High income countries perform more CT examinations per inhabitant. That suggests that planar X-ray examinations are replaced by CT examinations. (authors)

  11. Radiologic analysis of femoral acetabular impingement: from radiography to MRI

    Energy Technology Data Exchange (ETDEWEB)

    Dwek, Jerry R. [University of California at San Diego, Department of Radiology, Rady Children' s Hospital and Health Center, San Diego, CA (United States); San Diego Imaging, San Diego, CA (United States); Monazzam, Shafagh [Rady Children' s Hospital and Health Center, Department of Orthopedics, San Diego, CA (United States); Chung, Christine B. [University of California at San Diego, Department of Radiology, San Diego, CA (United States)

    2013-03-15

    Femoral acetabular impingement is a set of morphologic abnormalities that are considered to be a major cause of degenerative disease in the hip joint. Early changes are already present in adolescence when it is the pediatric radiologist who must assess current damage with the aim of averting progression to more severe and debilitating osteoarthritis. A multimodality approach is used for diagnosis, that includes conventional radiography and CT to assess the osseous structures. MR arthrography is the primary advanced imaging modality for assessment of morphologic changes as well as injuries of the labrum and articular cartilage. Details of radiologic imaging are offered to guide the radiologist and provide an avenue for the accurate description of the osseous and articular alterations and injury. (orig.)

  12. Diagnostic radiology for functional analysis of the cervical vertebral column

    International Nuclear Information System (INIS)

    Kamieth, H.

    1986-01-01

    The book is averaged in 17 chapters. The first three, introductory chapters dealing with the significance of radiology for the functional diagnosis of the cervical spine are followed by three chapters discussing the movements of the atlantoaxial joints, the statics of the cervical spine, and the sagittal flexural movements in the C2-C7 segments. Subsequent chapters discuss the radiodiagnostical method according to Arlen, the innervation of the cervical spine segments of movement, disturbances of movement including restriction of movement, degenerative processes of the invertebral disks, and hypermobile disturbance of movement. The final chapters deal with compensational and dissociation phenomena, subluxations, defective or compulsive positions, etc., the causes of each, and with the clinical relevance of spondylochondrosis and arthrosis, and with the pain. With 171 figs [de

  13. Preliminary analysis of alternative fuel cycles for proliferation evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Steindler, M. J.; Ripfel, H. C.F.; Rainey, R. H.

    1977-01-01

    The ERDA Division of Nuclear Research and Applications proposed 67 nuclear fuel cycles for assessment as to their nonproliferation potential. The object of the assessment was to determine which fuel cycles pose inherently low risk for nuclear weapon proliferation while retaining the major benefits of nuclear energy. This report is a preliminary analysis of these fuel cycles to develop the fuel-recycle data that will complement reactor data, environmental data, and political considerations, which must be included in the overall evaluation. This report presents the preliminary evaluations from ANL, HEDL, ORNL, and SRL and is the basis for a continuing in-depth study. (DLC)

  14. The radiology job market: analysis of the ACR jobs board.

    Science.gov (United States)

    Prabhakar, Anand M; Oklu, Rahmi; Harvey, H Benjamin; Harisinghani, Mukesh G; Rosman, David A

    2014-05-01

    The aim of this study was to assess the status of the radiology job market as represented by the ACR Jobs Board from October 2010 to June 2013. With the assistance of the ACR, data from the ACR Jobs Board from October 2010 through June 2013, including the numbers of monthly new job seekers, new job postings, and job posting clicks, were gathered and used to calculate a monthly competitive index, defined as the ratio of new job seekers to new job postings. During the study period, the mean number of new job seekers was 168 per month, which was significantly greater than the 84 average new job postings for any given month (P = .0002). There was no significant difference between 2011 and 2012 with regard to the number of new job seekers or job postings. Over the time period assessed, more new job seekers registered in October and November 2010, August to November 2011, and October and November 2012. These periods were also associated with the highest competitive index values. There were less job seekers in the winter and spring of 2011, 2012, and 2013, periods associated with lower competitive index values. ACR Jobs Board activity, measured by job posting clicks, was significantly higher in 2012 than in 2011 (P Jobs Board, there were consistently more new job seekers than job postings throughout the study period, and fall is the period in the year most associated with the highest competitive index for radiologist employment. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  15. antibacterial properties and preliminary phytochemical analysis

    African Journals Online (AJOL)

    DR. AMINU

    2Department of Pharmaceutical Chemistry, Faculty of Pharmacy, University of Benin, Benin City. *Correspondence ... phytochemical analysis of the dried leaves extracts revealed the presence of alkaloids, ... for the synthesis of useful drugs.

  16. Preliminary conceptual design and analysis on KALIMER reactor structures

    International Nuclear Information System (INIS)

    Kim, Jong Bum

    1996-10-01

    The objectives of this study are to perform preliminary conceptual design and structural analyses for KALIMER (Korea Advanced Liquid Metal Reactor) reactor structures to assess the design feasibility and to identify detailed analysis requirements. KALIMER thermal hydraulic system analysis results and neutronic analysis results are not available at present, only-limited preliminary structural analyses have been performed with the assumptions on the thermal loads. The responses of reactor vessel and reactor internal structures were based on the temperature difference of core inlet and outlet and on engineering judgments. Thermal stresses from the assumed temperatures were calculated using ANSYS code through parametric finite element heat transfer and elastic stress analyses. While, based on the results of preliminary conceptual design and structural analyses, the ASME Code limits for the reactor structures were satisfied for the pressure boundary, the needs for inelastic analyses were indicated for evaluation of design adequacy of the support barrel and the thermal liner. To reduce thermal striping effects in the bottom are of UIS due to up-flowing sodium form reactor core, installation of Inconel-718 liner to the bottom area was proposed, and to mitigate thermal shock loads, additional stainless steel liner was also suggested. The design feasibilities of these were validated through simplified preliminary analyses. In conceptual design phase, the implementation of these results will be made for the design of the reactor structures and the reactor internal structures in conjunction with the thermal hydraulic, neutronic, and seismic analyses results. 4 tabs., 24 figs., 4 refs. (Author)

  17. Experience with PET FDG - Preliminary analysis

    International Nuclear Information System (INIS)

    Massardo, Teresa; Jofre, Josefina; Canessa, Jose; Gonzalez, Patricio; Humeres, Pamela; Sierralta, Paulina; Galaz, Rodrigo; Miranda, Karina

    2004-01-01

    Full text: The objective of this preliminary communication was to analyse the indications and data in initial group of patients studied with first dedicated PET scanner in the country at Hospital Militar in Santiago Chile. The main application of positron emission tomography (PET) with 18-Fluoro deoxyglucose (FDG) is related with oncological patients management. We studied 136 patients, 131 (97%) with known or suspected malignant disease and remaining 5 for cardiological or neuropsychiatric disease. Ten patients were controlled diabetics (1 insulin dependent). Their mean age was 51.6±18 years ranging from 6 to 84 years and 65% were females. A total of 177 scans were acquired using a dedicated PET (Siemens HR + with 4mm resolution) system. Mean F18-FDG injected dose was 477±107 MBq (12.9±2.9 mCi). Mean blood glucose levels, performed prior the injection, were 94±17mg/dl (range 62-161). F18-FDG was obtained from the cyclotron IBA Cyclone 18/9 installed in the Chilean Agency of Nuclear Energy, distant about 15 miles away from the clinical PET facility. PET studies were analyzed by at least 4 independent observers visually. Standardized uptake value (SUV) was calculated in some cases. Image fusion of FDG images with recent anatomical (CT, MRI) studies was performed where available. Data acquisition protocol consisted in 7-8 beds/study from head to mid-thighs, with 6-7-min/bed acquisitions, 36% transmission with germanium 68 rods. Data was reconstructed with standard OSEM protocol. The main indications included pulmonary lesions in 31%, gastrointestinal cancers in 21%, melanoma in 13% and lymphoma in 9% patients. The remaining were of breast, thyroid, testes, ovary, musculoskeletal (soft tissue and bone), brain tumour etc. Abnormal focal tracer uptake was observed in 83/131 oncological patients, 54% corroborating with clinical diagnosis of primary tumor or recurrence while 46% showed new metastatic localization. FDG scans were normal 36/131 patients. In 9 patients

  18. Experience with PET FDG - Preliminary analysis

    Energy Technology Data Exchange (ETDEWEB)

    Massardo, Teresa; Jofre, Josefina; Canessa, Jose; Gonzalez, Patricio; Humeres, Pamela; Sierralta, Paulina; Galaz, Rodrigo; Miranda, Karina [Centro PET de Imagenes Moleculares, Hospital Militar de Santiago, Santiago (Chile)

    2004-01-01

    Full text: The objective of this preliminary communication was to analyse the indications and data in initial group of patients studied with first dedicated PET scanner in the country at Hospital Militar in Santiago Chile. The main application of positron emission tomography (PET) with 18-Fluoro deoxyglucose (FDG) is related with oncological patients management. We studied 136 patients, 131 (97%) with known or suspected malignant disease and remaining 5 for cardiological or neuropsychiatric disease. Ten patients were controlled diabetics (1 insulin dependent). Their mean age was 51.6{+-}18 years ranging from 6 to 84 years and 65% were females. A total of 177 scans were acquired using a dedicated PET (Siemens HR + with 4mm resolution) system. Mean F18-FDG injected dose was 477{+-}107 MBq (12.9{+-}2.9 mCi). Mean blood glucose levels, performed prior the injection, were 94{+-}17mg/dl (range 62-161). F18-FDG was obtained from the cyclotron IBA Cyclone 18/9 installed in the Chilean Agency of Nuclear Energy, distant about 15 miles away from the clinical PET facility. PET studies were analyzed by at least 4 independent observers visually. Standardized uptake value (SUV) was calculated in some cases. Image fusion of FDG images with recent anatomical (CT, MRI) studies was performed where available. Data acquisition protocol consisted in 7-8 beds/study from head to mid-thighs, with 6-7-min/bed acquisitions, 36% transmission with germanium 68 rods. Data was reconstructed with standard OSEM protocol. The main indications included pulmonary lesions in 31%, gastrointestinal cancers in 21%, melanoma in 13% and lymphoma in 9% patients. The remaining were of breast, thyroid, testes, ovary, musculoskeletal (soft tissue and bone), brain tumour etc. Abnormal focal tracer uptake was observed in 83/131 oncological patients, 54% corroborating with clinical diagnosis of primary tumor or recurrence while 46% showed new metastatic localization. FDG scans were normal 36/131 patients. In 9

  19. Preliminary engineering analysis for clothes washers

    Energy Technology Data Exchange (ETDEWEB)

    Biermayer, Peter J.

    1996-10-01

    The Engineering Analysis provides information on efficiencies, manufacturer costs, and other characteristics of the appliance class being analyzed. For clothes washers, there are two classes: standard and compact. Since data were not available to analyze the compact class, only clothes washers were analyzed in this report. For this analysis, individual design options were combined and ordered in a manner that resulted in the lowest cumulative cost/savings ratio. The cost/savings ratio is the increase in manufacturer cost for a design option divided by the reduction in operating costs due to fuel and water savings.

  20. Data analysis and review of radiology services at Glasgow 2014 Commonwealth Games.

    Science.gov (United States)

    Bethapudi, Sarath; Ritchie, David; Bongale, Santosh; Gordon, Jonny; MacLean, John; Mendl, Liz

    2015-10-01

    Medical services at the Glasgow 2014 Commonwealth Games (CWG) were provided though a purpose-built medical polyclinic, which had a fully equipped radiology department along with other services, set up within the main Games Village. Data analysis of radiology services offered at CWG has not been published before. Imaging services within the polyclinic, Athletes Village, Glasgow 2014 CWG. The aim of the paper is to analyse data on radiological investigations and assess the demand and distribution of workload on imaging services at CWG 2014. Data on radiology investigations at the CWG 2014 was retrieved from the Carestream picture archiving and communication system (PACS) and Pharmasys (CWG official centralised electronic database system) and analysed. Six hundred ninety-seven diagnostic and interventional procedures were performed. Of these 37.9% were magnetic resonance imaging (MRI) scans, 22% were diagnostic ultrasound (US) examinations, 33.1% were radiographs, 4.3% were computed tomography (CT) scans and 2.7% were imaging-guided interventional procedures. 88% of imaging was performed on athletes and the remainder were performed on team officials and workforce. Demand on radiology services gradually picked up through the pre-competition period and peaked half way through the CWG. Radiology played a vital role in the successful provision of medical services at the Glasgow 2014 CWG. High demand on imaging services can be expected at major international sporting events and therefore pre-event planning is vital. Having back-up facilities in case of technical failure should be given due importance when planning radiology services at future CWG events.

  1. Data analysis and review of radiology services at Glasgow 2014 Commonwealth Games

    International Nuclear Information System (INIS)

    Bethapudi, Sarath; Ritchie, David; Bongale, Santosh; Gordon, Jonny; MacLean, John; Mendl, Liz

    2015-01-01

    Medical services at the Glasgow 2014 Commonwealth Games (CWG) were provided though a purpose-built medical polyclinic, which had a fully equipped radiology department along with other services, set up within the main Games Village. Data analysis of radiology services offered at CWG has not been published before. Imaging services within the polyclinic, Athletes Village, Glasgow 2014 CWG. The aim of the paper is to analyse data on radiological investigations and assess the demand and distribution of workload on imaging services at CWG 2014. Data on radiology investigations at the CWG 2014 was retrieved from the Carestream picture archiving and communication system (PACS) and Pharmasys (CWG official centralised electronic database system) and analysed. Six hundred ninety-seven diagnostic and interventional procedures were performed. Of these 37.9 % were magnetic resonance imaging (MRI) scans, 22 % were diagnostic ultrasound (US) examinations, 33.1 % were radiographs, 4.3 % were computed tomography (CT) scans and 2.7 % were imaging-guided interventional procedures. 88 % of imaging was performed on athletes and the remainder were performed on team officials and workforce. Demand on radiology services gradually picked up through the pre-competition period and peaked half way through the CWG. Radiology played a vital role in the successful provision of medical services at the Glasgow 2014 CWG. High demand on imaging services can be expected at major international sporting events and therefore pre-event planning is vital. Having back-up facilities in case of technical failure should be given due importance when planning radiology services at future CWG events. (orig.)

  2. Data analysis and review of radiology services at Glasgow 2014 Commonwealth Games

    Energy Technology Data Exchange (ETDEWEB)

    Bethapudi, Sarath [County Durham Darlington Foundation NHS Trust, Durham (United Kingdom); Glasgow 2014 Commonwealth Games, Glasgow (United Kingdom); Ritchie, David [Glasgow 2014 Commonwealth Games, Glasgow (United Kingdom); Greater Glasgow and Clyde Hospitals NHS Trust, Western Infirmary, Glasgow (United Kingdom); Bongale, Santosh [Glasgow 2014 Commonwealth Games, Immediate Care Department, Glasgow (United Kingdom); NHS Greater Glasgow and Clyde, Royal Alexandra Hospital, Paisley (United Kingdom); Gordon, Jonny [Glasgow 2014 Commonwealth Games, Glasgow (United Kingdom); NHS Greater Glasgow and Clyde, Glasgow (United Kingdom); MacLean, John [Glasgow 2014 Commonwealth Games, Glasgow (United Kingdom); National Stadium Sports Medicine Centre, Glasgow (United Kingdom); Mendl, Liz [Glasgow 2014 Commonwealth Games, Glasgow (United Kingdom)

    2015-10-15

    Medical services at the Glasgow 2014 Commonwealth Games (CWG) were provided though a purpose-built medical polyclinic, which had a fully equipped radiology department along with other services, set up within the main Games Village. Data analysis of radiology services offered at CWG has not been published before. Imaging services within the polyclinic, Athletes Village, Glasgow 2014 CWG. The aim of the paper is to analyse data on radiological investigations and assess the demand and distribution of workload on imaging services at CWG 2014. Data on radiology investigations at the CWG 2014 was retrieved from the Carestream picture archiving and communication system (PACS) and Pharmasys (CWG official centralised electronic database system) and analysed. Six hundred ninety-seven diagnostic and interventional procedures were performed. Of these 37.9 % were magnetic resonance imaging (MRI) scans, 22 % were diagnostic ultrasound (US) examinations, 33.1 % were radiographs, 4.3 % were computed tomography (CT) scans and 2.7 % were imaging-guided interventional procedures. 88 % of imaging was performed on athletes and the remainder were performed on team officials and workforce. Demand on radiology services gradually picked up through the pre-competition period and peaked half way through the CWG. Radiology played a vital role in the successful provision of medical services at the Glasgow 2014 CWG. High demand on imaging services can be expected at major international sporting events and therefore pre-event planning is vital. Having back-up facilities in case of technical failure should be given due importance when planning radiology services at future CWG events. (orig.)

  3. Cost-benefit analysis for U.S. NRC proposed radiological criteria for decommissioning

    International Nuclear Information System (INIS)

    Meck, R.A.

    1995-01-01

    The U.S. Nuclear Regulatory Commission prepared cost-benefit analyses in support of the proposed regulation on radiological criteria for decommissioning. These analyses have been published in the Draft Generic Environmental Impact Statement (GEIS), NUREG-1496, and in the Draft Regulatory Analysis (RA). The method used was to first list the reasonable regulatory alternatives that could be considered. Second, for each regulatory alternative, we analyzed and compared the costs and the incremental radiological and non-radiological impacts to workers and members of the public. The regulatory alternatives for unrestricted use of a site that were analyzed and compared were: no regulatory change; a uniform risk based on total effective dose equivalent (TEDE); use of 'best' available technology; and returning the level of radioactivity attributable to licensed activity to background levels. The analyses were performed for ten types of reference facilities, and each facility was evaluated at low, medium, and high levels of contamination. The reference facilities included: reactors; various uranium and non-fuel cycle facilities; and independent spent fuel storage installations. Since both the radiological and non-radiological benefits were considered, the benefits of the various alternatives were measured in terms of 'Estimated Mortalities Averted.' Conclusions supported by the analyses were that a risk limit, expressed as a 15 mrem/y dose, is reasonable both as a level for protecting public health and safety and with regard to its cost-benefit effects. Further reductions on a site-specific application of the ALARA principle are also supported in the context of accounting for both the radiological and non-radiological effects in both the short and long terms. Restricted release is also supported when the same level of protection is provided in decommissioning those facilities that cannot reasonably meet the unrestricted release criteria. (J.P.N.)

  4. Clinical and radiologic analysis of the pancreatic pseudocyst

    International Nuclear Information System (INIS)

    Lee, Jong Yul; Chung, Bong Jin; Kim, Sung Soo; Park, Sam Kyoon

    1985-01-01

    Pancreatic pseudocyst is encapsulated collections of exudate, blood, and secretions that result from pancreatic necrosis or rupture of ducts and acini, and frequently result in various life threating complications. The barium study of the upper G.I. tract is the most valuable method in diagnosis of the pancreatic pseudocyst. Total 30 cases of surgically proved pancreatic pseudocyst were analyzed. The results were as follows: 1. 56.6% was male, and peak incidence was in the 5th decade. 2. Etiologic factors were blunt abdominal trauma (30%) pancreatitis (23%), and unknown (47%). 3. The most important radiologic findings was stomach displacement(100%), and the others were colon displacement (69%), mass seen in simple abdomen (67%), left kidney displacement (46%), duodental deformity (40%), elevation of diaphragm (37%), pleural effusion (27%), and pancreatic calcification (7%). 4. The most frequent site of the pseudocyst in U.G.I. series was between the greater curvature of the antrum of the stomach and transverse colon (40%). The other sites were near the incisura angularis of the lesser curvature (12%), greater curvature of the antrum (12%), and greater curvature of the body of stomach (4%). 5. The location of the pseudocyst was mainly in the body and tail of the pancreas (90%), only 3 cases (10%) was in the head.

  5. Radiologic analysis of the medical collateral ligament rupture

    International Nuclear Information System (INIS)

    Cho, Chung Che; Lee, Chang Jun; Kim, Kun Sang; Park, Soo Soung

    1979-01-01

    The medical collateral ligament rupture is the most common injury involving the knee joint ligaments. The ruptured medical collateral ligaments of 73 cases with clinical and surgical confirmations were radiologically analyzed. The results were obtained as follows: 1. The most risky age for tearing of the medical collateral ligament was third to fifth decades (50 cases of male and 23 of females). 2. The most common cause of the medical collateral ligament rupture was traffic accident (82.2%). 3. The mean distance of medial knee joint space was 7.9 ± 2.0 mm on the normal side and 13.7 ± 4.2 mm on the affected side. 4. The mean degree of knee joint space was 10.1 ± 2.5 on the normal side and 14.7 ± 3.8 on the affected side. 5. The fibula was the bone fractured most frequently in association with the medial collateral ligament rupture (30.6%).

  6. Analysis of dose distribution in interventionist radiology professionals

    International Nuclear Information System (INIS)

    Mauricio, Claudia L.P.; Silva, Leonardo Peres; Canevaro, Lucia V.; Luz, Eara de Souza

    2005-01-01

    In this work, an evaluation was made of the distribution of dose received by professionals involved in some procedures of Interventional Radiology at hospitals and clinics in Rio de Janeiro, RJ, Brazil. For these measurements thermoluminescent dosemeters (TLD) of LiF: Mg, Ti (TLD100) were used, positioned at different points of the body of professionals: the hands, knees, neck, forehead and chest, inside and outside the lead apron. The measurements were made by procedure and/or a day of work, and the TLD were calibrated in equivalent operating magnitude of personal dose (Hp (d)) at different depths: 0.07 mm, 3 mm and 10 mm. In some procedures, physicians (holders of service and residents) received significant doses. The results show the importance of the appropriate training of these professionals and the use of personal protective equipment (PPE), such as thyroid shield, which is not always used. Based on these evaluations, some suggestions were made in order to optimize the dose values in these procedures and a discussion on the need for additional monitoring points

  7. Radiological Analysis of 40 K, 226 Ra and 232 Th in Fish ...

    African Journals Online (AJOL)

    Radiological analysis was carried out on fish, crustacean and sediment samples collected from both fresh and marine water of river Igbokoda in the coastal area of Ondo State, Nigeria. The activity concentrations of radionuclides were determined using gamma spectrometry method. The means of the annual effective ...

  8. Radiological analysis of materials sampled on the old nuclear test site of In Ekker (Algeria)

    International Nuclear Information System (INIS)

    Chareyron, Bruno

    2010-01-01

    After having recalled the context of the French nuclear test campaign in Algeria between 1961 and 1966, this document reports and comments radiological measurements performed on the site of In Ekker, and also results of analysis performed in laboratory (contamination by cesium 137, americium 241, plutonium); recommendations are given

  9. Radiological emergency response for community agencies with cognitive task analysis, risk analysis, and decision support framework.

    Science.gov (United States)

    Meyer, Travis S; Muething, Joseph Z; Lima, Gustavo Amoras Souza; Torres, Breno Raemy Rangel; del Rosario, Trystyn Keia; Gomes, José Orlando; Lambert, James H

    2012-01-01

    Radiological nuclear emergency responders must be able to coordinate evacuation and relief efforts following the release of radioactive material into populated areas. In order to respond quickly and effectively to a nuclear emergency, high-level coordination is needed between a number of large, independent organizations, including police, military, hazmat, and transportation authorities. Given the complexity, scale, time-pressure, and potential negative consequences inherent in radiological emergency responses, tracking and communicating information that will assist decision makers during a crisis is crucial. The emergency response team at the Angra dos Reis nuclear power facility, located outside of Rio de Janeiro, Brazil, presently conducts emergency response simulations once every two years to prepare organizational leaders for real-life emergency situations. However, current exercises are conducted without the aid of electronic or software tools, resulting in possible cognitive overload and delays in decision-making. This paper describes the development of a decision support system employing systems methodologies, including cognitive task analysis and human-machine interface design. The decision support system can aid the coordination team by automating cognitive functions and improving information sharing. A prototype of the design will be evaluated by plant officials in Brazil and incorporated to a future trial run of a response simulation.

  10. Analysis of radiological consequences in a typical BWR with a mark-II containment

    International Nuclear Information System (INIS)

    Funayama, Kyoko; Kajimoto, Mitsuhiro

    2003-01-01

    INS/NUPEC in Japan has been carrying out the Level 3 PSA program. In the program, the MACCS2 code has been extensively applied to analyze radiological consequences for typical BWR and PWR plants in Japan. The present study deals with analysis of effects of the AMs, which were implemented by industries, on radiological consequence for a typical BWR with a Mark-II containment. In the present study, source terms and their frequencies of source terms were used based on results of Level 2 PSA taking into account AM countermeasures. Radiological consequences were presented with dose risks (Sv/ry), which were multiplied doses (Sv) by containment damage frequencies (/ry), and timing of radionuclides release to the environment. The results of the present study indicated that the dose risks became negligible in most cases taking AM countermeasures and evacuations. (author)

  11. Preliminary analysis of the KAERI RCCS Experiment Using GAMMA+

    Energy Technology Data Exchange (ETDEWEB)

    Khoza, Samukelisiwe; Tak, Nam-il; Lim, Hong-Sik; Lee, Sung-Nam; Cho, Bong-Hyun; Kim, Jong-Hwan [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    This paper describes the analysis of the KAERI RCCS experiment. GAMMA+ code was used for analysis of the RCCS 1/4-scale natural cooling experimental facility designed and built at KAERI to verify the performance of the natural circulation phenomenon. The results obtained from the GAMMA+ analysis showing the temperature profiles and flow rates at steady state were compared with the results from the preliminary experiments conducted in this facility. GAMMA+ analysis for the KAERI RCCS experimental setup was carried out to understand its natural circulation behavior. The air flow rate at the chimney exit achieved by experiments was from to be almost same as that of GAMMA+.

  12. Gravity field of Venus - A preliminary analysis

    Science.gov (United States)

    Phillips, R. J.; Sjogren, W. L.; Abbott, E. A.; Smith, J. C.; Wimberly, R. N.; Wagner, C. A.

    1979-01-01

    The gravitational field of Venus obtained by tracking the Pioneer Venus Orbiter is examined. For each spacecraft orbit, two hours of Doppler data centered around periapsis were used to estimate spacecraft position and velocity and the velocity residuals obtained were spline fit and differentiated to produce line of sight gravitational accelerations. Consistent variations in line of sight accelerations from orbit to orbit reveal the presence of gravitational anomalies. A simulation of isostatic compensation for an elevated region on the surface of Venus indicates that the mean depth of compensation is no greater than about 100 km. Gravitational spectra obtained from a Fourier analysis of line of sight accelerations from selected Venus orbits are compared to the earth's gravitational spectrum and spherical harmonic gravitational potential power spectra of the earth, the moon and Mars. The Venus power spectrum is found to be remarkably similar to that of the earth, however systematic variations in the harmonics suggest differences in dynamic processes or lithospheric behavior.

  13. Advanced high conversion PWR: preliminary analysis

    International Nuclear Information System (INIS)

    Golfier, H.; Bellanger, V.; Bergeron, A.; Dolci, F.; Gastaldi, B.; Koberl, O.; Mignot, G.; Thevenot, C.

    2007-01-01

    In this paper, physical aspects of a HCPWR (High Conversion Light Water Reactor), which is an innovative PWR fuelled with mixed oxide and having a higher conversion ratio due to a lower moderation ratio. Moderation ratios lower than unity are considered which has led to low moderation PWR fuel assembly designs. The objectives of this parametric study are to define a feasibility area with regard to the following neutronic aspects: moderation ratio, Pu loading, reactor spectrum, irradiation time, and neutronic coefficients. Important thermohydraulic parameters are the pressure drop, the critical heat flux, the maximum temperature in the fuel rod and the pumping power. The thermohydraulic analysis shows that a range of moderation ratios from 0.8 to 1.2 is technically possible. A compromise between improved fuel utilization and research and development effort has been found for the moderation ration of about 1. The parametric study shows that there are 2 ranges of interest for the moderation ratio: -) moderation ratio between 0.8 and 1.2 with reduced fissile heights (> 3 m), hexagonal arrangement fuel assembly and square arrangement fuel assembly are possible; and -) moderation between 0.6 and 0.7 with a modification of the reactor operating conditions (reduction of the primary flow and of the thermal power), the fuel rods could be arranged inside a hexagonal fuel rod assembly. (A.C.)

  14. A preliminary analysis of bidayuh Jagoi patun

    Directory of Open Access Journals (Sweden)

    Dayang Sariah Abang Suhai

    2013-12-01

    Full Text Available Bidayuh Pantun or Patun remains a under researched topic in Borneo studies and language research due to the difficulties associated with obtaining critical, poetic information in oral culture, language variations and societal mobility. Existing data from anthologies however provide little detail about the instrinsic and extrinsic features ascribed to the poem by the people who produce and use them. This paper attempts to explore patun from the Jagoi community. In this study, the structural aspects, themes and moral values of 47 patun from the Jagoi community were analysed. The initial explanations suggested by the poet were further analysed to determine the various structural features to place it alongside existing mainstream lyric poetry. The analysis of the intrinsic features showed that good rhythmic patun has four to six words per line and eight to 12 syllables per line, and the final syllables of each line has assonance and consonance patterns of a-a-a-a and a-b-a-b. The themes of the patun include love, advice, forgiveness, beliefs, hopelessness and happiness, and the moral values take the form of subtle advice and admonishments. The Bidayuh patun is indeed a projection of knowledge, experiences, beliefs, values, and emotions of the community.

  15. Surface Properties of TNOs: Preliminary Statistical Analysis

    Science.gov (United States)

    Antonieta Barucci, Maria; Fornasier, S.; Alvarez-Cantal, A.; de Bergh, C.; Merlin, F.; DeMeo, F.; Dumas, C.

    2009-09-01

    An overview of the surface properties based on the last results obtained during the Large Program performed at ESO-VLT (2007-2008) will be presented. Simultaneous high quality visible and near-infrared spectroscopy and photometry have been carried out on 40 objects with various dynamical properties, using FORS1 (V), ISAAC (J) and SINFONI (H+K bands) mounted respectively at UT2, UT1 and UT4 VLT-ESO telescopes (Cerro Paranal, Chile). For spectroscopy we computed the spectral slope for each object and searched for possible rotational inhomogeneities. A few objects show features in their visible spectra such as Eris, whose spectral bands are displaced with respect to pure methane-ice. We identify new faint absorption features on 10199 Chariklo and 42355 Typhon, possibly due to the presence of aqueous altered materials. The H+K band spectroscopy was performed with the new instrument SINFONI which is a 3D integral field spectrometer. While some objects show no diagnostic spectral bands, others reveal surface deposits of ices of H2O, CH3OH, CH4, and N2. To investigate the surface properties of these bodies, a radiative transfer model has been applied to interpret the entire 0.4-2.4 micron spectral region. The diversity of the spectra suggests that these objects represent a substantial range of bulk compositions. These different surface compositions can be diagnostic of original compositional diversity, interior source and/or different evolution with different physical processes affecting the surfaces. A statistical analysis is in progress to investigate the correlation of the TNOs’ surface properties with size and dynamical properties.

  16. Preliminary Seismic Response and Fragility Analysis for DACS Cabinet

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Jinho; Kwag, Shinyoung; Lee, Jongmin; Kim, Youngki [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    A DACS cabinet is installed in the main control room. The objective of this paper is to perform seismic analyses and evaluate the preliminary structural integrity and seismic capacity of the DACS cabinet. For this purpose, a 3-D finite element model of the DACS cabinet was developed and its modal analyses are carried out to analyze the dynamic characteristics. The response spectrum analyses and the related safety evaluation are then performed for the DACS cabinet subject to seismic loads. Finally, the seismic margin and seismic fragility of the DACS cabinet are investigated. A seismic analysis and preliminary structural integrity of the DACS cabinet under self weight and SSE load have been evaluated. For this purpose, 3-D finite element models of the DACS cabinet were developed. A modal analysis, response spectrum analysis, and seismic fragility analysis were then performed. From the structural analysis results, the DACS cabinet is below the structural design limit of under SSE 0.3g, and can structurally withstand until less than SSE 3g based on an evaluation of the maximum effective stresses. The HCLPF capacity for the DGRS of the SSE 0.3g is 0.55g. A modal analysis, response spectrum analysis, and seismic fragility analysis were then performed. From the structural analysis results, the DACS cabinet is below the structural design limit of under SSE 0.3g, and can structurally withstand until less than SSE 3g based on an evaluation of the maximum effective stresses. The HCLPF capacity for the DGRS of the SSE 0.3g is 0.55g. Therefore, it is concluded that the DACS cabinet was safely designed in that no damage to the preliminary structural integrity and sufficient seismic margin is expected.

  17. Preliminary Seismic Response and Fragility Analysis for DACS Cabinet

    International Nuclear Information System (INIS)

    Oh, Jinho; Kwag, Shinyoung; Lee, Jongmin; Kim, Youngki

    2013-01-01

    A DACS cabinet is installed in the main control room. The objective of this paper is to perform seismic analyses and evaluate the preliminary structural integrity and seismic capacity of the DACS cabinet. For this purpose, a 3-D finite element model of the DACS cabinet was developed and its modal analyses are carried out to analyze the dynamic characteristics. The response spectrum analyses and the related safety evaluation are then performed for the DACS cabinet subject to seismic loads. Finally, the seismic margin and seismic fragility of the DACS cabinet are investigated. A seismic analysis and preliminary structural integrity of the DACS cabinet under self weight and SSE load have been evaluated. For this purpose, 3-D finite element models of the DACS cabinet were developed. A modal analysis, response spectrum analysis, and seismic fragility analysis were then performed. From the structural analysis results, the DACS cabinet is below the structural design limit of under SSE 0.3g, and can structurally withstand until less than SSE 3g based on an evaluation of the maximum effective stresses. The HCLPF capacity for the DGRS of the SSE 0.3g is 0.55g. A modal analysis, response spectrum analysis, and seismic fragility analysis were then performed. From the structural analysis results, the DACS cabinet is below the structural design limit of under SSE 0.3g, and can structurally withstand until less than SSE 3g based on an evaluation of the maximum effective stresses. The HCLPF capacity for the DGRS of the SSE 0.3g is 0.55g. Therefore, it is concluded that the DACS cabinet was safely designed in that no damage to the preliminary structural integrity and sufficient seismic margin is expected

  18. Analysis and evaluation of the radiological aspects of scoliosis

    International Nuclear Information System (INIS)

    Vargas Gonzalez, Paula

    2012-01-01

    The theme of scoliosis is proposed from the radiological perspective. An extensive literature review is realized, extracting the most relevant information for research. The initiation and evolution of scoliosis has been silent, therefore, to meet this condition has been important to detect it early and opportunely, before that curvatures have progressed and become structured, forcing the surgical treatment. The timely correction of curvatures in the spine has generated significant conditions in the patient's life. The early diagnosis has been fundamental to realize an opportune treatment of orthopedic type. A great variety of congenital and developmental disorders have been evident in the spine. The causes and patterns of the abnormal curvature of the spine have been varied. Precise diagnosis of these alterations is supported on a careful clinical assessment and is aided by imaging explorations, such as conventional radiography, computed tomography, ultrasound and magnetic resonance. Imaging methods to detect scoliosis are mentioned. The measurement procedures of the angle of spine curve are determined. The classification of scoliosis according to King-Lenke are cited to facilitate objective assessment of a disease for examiners, making that the results are presented in shape uniform and comparable possible. The types of scoliosis are explained. The characterization of the deformities of the axis of the spine, quantification and estimation of the degree of skeletal maturity has been the principal objective of the spine radiography. In an radiography has been important to be included all the thoracolumbar spine from C7. The Cobb and Ferguson measurements are used to measure angles, Risser for skeletal maturation, Nas and Moe for vertical rotation. Congenital deformities should be taken into account in radiographs of spine. Each vertebra is examined minutely in search of malformations of fusion, etc., that explain scoliosis. In neurological disorders, to take

  19. Radiological optimization

    International Nuclear Information System (INIS)

    Zeevaert, T.

    1998-01-01

    Radiological optimization is one of the basic principles in each radiation-protection system and it is a basic requirement in the safety standards for radiation protection in the European Communities. The objectives of the research, performed in this field at the Belgian Nuclear Research Centre SCK-CEN, are: (1) to implement the ALARA principles in activities with radiological consequences; (2) to develop methodologies for optimization techniques in decision-aiding; (3) to optimize radiological assessment models by validation and intercomparison; (4) to improve methods to assess in real time the radiological hazards in the environment in case of an accident; (5) to develop methods and programmes to assist decision-makers during a nuclear emergency; (6) to support the policy of radioactive waste management authorities in the field of radiation protection; (7) to investigate existing software programmes in the domain of multi criteria analysis. The main achievements for 1997 are given

  20. Preliminary report of radiological safety to hydrology 1993 campaign; Informe preliminar de seguridad radiologica para la campana de hidrologia 1993

    Energy Technology Data Exchange (ETDEWEB)

    Badano, A; Suarez Antola, R; Dellepere, A; Barreiro, M [MIEM, Direccion Nacional de Tecnologia Nuclear, Montevideo (Uruguay)

    1993-07-01

    This report has been prepared based on the interaction between project managers and division radiological Protection and Nuclear Safety. In seeking to establish a basis for approval from the point of view of radiation safety practices . The idea for the audit has been provided at all times because the interest was the exchange of ideas and the use of common sense to improve the safety of radioactive substances, security of operators and public safety and environment.The above shows that in the planned radiation safety condition described in this report,the practice can be carried out according to the criteria of safety accepted .

  1. Preliminary Mass Spectrometric Analysis of Uranium on Environmental Swipe Materials

    International Nuclear Information System (INIS)

    Cheong, Chang-Sik; Jeong, Youn-Joong; Ryu, Jong-Sik; Shin, Hyung-Seon; Cha, Hyun-Ju; Ahn, Gil-Hoon; Park, Il-Jin; Min, Gyung-Sik

    2006-01-01

    It is well-known that uranium and plutonium isotopic compositions of safeguards samples are very useful to investigate the history of nuclear activities. To strengthen the capabilities of environmental sampling analysis in the ROK through MOST/DOE collaboration, round robin test for uranium and plutonium was designed in 2003. As the first round robin test, a set of dried uranium-containing solutions (∼35ng and (∼300ng) was distributed to the participating laboratories in November of 2003, with results reported in April of 2004. The KBSI (Korea Basic Science Institute) and ORNL (Oak Ridge National Laboratory) are currently in the process of analyzing uranium on cotton swipes for the second round robin test. As a preliminary test for the second round, KBSI intends to analyze home-made swipe samples into which international uranium standards are added. Here we describe technical steps of sample preparation and mass spectrometry at KBSI, and report some results of the preliminary test

  2. Active cooling for downhole instrumentation: Preliminary analysis and system selection

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, G.A.

    1988-03-01

    A feasibility study and a series of preliminary designs and analyses were done to identify candidate processes or cycles for use in active cooling systems for downhole electronic instruments. A matrix of energy types and their possible combinations was developed and the energy conversion process for each pari was identified. The feasibility study revealed conventional as well as unconventional processes and possible refrigerants and identified parameters needing further clarifications. A conceptual design or series od oesigns for each system was formulated and a preliminary analysis of each design was completed. The resulting coefficient of performance for each system was compared with the Carnot COP and all systems were ranked by decreasing COP. The system showing the best combination of COP, exchangeability to other operating conditions, failure mode, and system serviceability is chosen for use as a downhole refrigerator. 85 refs., 48 figs., 33 tabs.

  3. Preliminary study of soil permeability properties using principal component analysis

    Science.gov (United States)

    Yulianti, M.; Sudriani, Y.; Rustini, H. A.

    2018-02-01

    Soil permeability measurement is undoubtedly important in carrying out soil-water research such as rainfall-runoff modelling, irrigation water distribution systems, etc. It is also known that acquiring reliable soil permeability data is rather laborious, time-consuming, and costly. Therefore, it is desirable to develop the prediction model. Several studies of empirical equations for predicting permeability have been undertaken by many researchers. These studies derived the models from areas which soil characteristics are different from Indonesian soil, which suggest a possibility that these permeability models are site-specific. The purpose of this study is to identify which soil parameters correspond strongly to soil permeability and propose a preliminary model for permeability prediction. Principal component analysis (PCA) was applied to 16 parameters analysed from 37 sites consist of 91 samples obtained from Batanghari Watershed. Findings indicated five variables that have strong correlation with soil permeability, and we recommend a preliminary permeability model, which is potential for further development.

  4. Preliminary Safety Analysis Report for the Tokamak Physics Experiment

    International Nuclear Information System (INIS)

    Motloch, C.G.; Bonney, R.F.; Levine, J.D.; Masson, L.S.; Commander, J.C.

    1995-04-01

    This Preliminary Safety Analysis Report (PSAR), includes an indication of the magnitude of facility hazards, complexity of facility operations, and the stage of the facility life-cycle. It presents the results of safety analyses, safety assurance programs, identified vulnerabilities, compensatory measures, and, in general, the rationale describing why the Tokamak Physics Experiment (TPX) can be safely operated. It discusses application of the graded approach to the TPX safety analysis, including the basis for using Department of Energy (DOE) Order 5480.23 and DOE-STD-3009-94 in the development of the PSAR

  5. The impact of European research ethics legislation on UK radiology research activity: a bibliometric analysis

    International Nuclear Information System (INIS)

    Johnson, C.A.; Toms, A.P.

    2009-01-01

    Aim: To determine whether there is evidence of a reduction in radiology research activity in the UK following the implementation of the European research ethics legislation, which came in to force in 2001 and has been widely criticised as an impediment to research. Materials and methods: A bibliometric analysis was performed by searching PubMed for all first-author publications from UK departments of 'radiology' or 'medical imaging' between 1995 and 2007. Results were subcategorized into those papers published in the highest cited general radiology journals and by publication type: original research, reviews, and case reports. Results: From 1995 to 2007 the total number of publications rose by 6.5% from 137 to 146 with the increase occurring in non-general radiology journals. Original articles fell from 18 in 1995 to 12 in 2003, but then rose to 24 by 2007 (33% rise). This dip was paralleled by a fall and then recovery in case report publications. The most dramatic change has been in the number of review articles, which has increased more than eightfold from seven in 1995 to 65 in 2007 to become the most common form of publication. Conclusion: The overall number of original scientific articles, published by first-author UK radiologists, has increased slightly over the last 12 years despite a temporary fall associated with the introduction of new research ethics legislation.

  6. Activity-based cost analysis in catheter-based angiography and interventional radiology

    International Nuclear Information System (INIS)

    Rautio, R.; Keski-Nisula, L.; Paakkala, T.

    2003-01-01

    The aim of this study was to analyse the costs of the interventional radiology unit and to identify the cost factors in the different activities of catheter-based angiographies and interventional radiology. In 1999 the number of procedures in the interventional radiological unit at Tampere University Hospital was 2968; 1601 of these were diagnostic angiographies, 526 endovascular and 841 nonvascular interventions. The costs were analysed by using Activity Based Cost (ABC) analysis. The budget of the interventional unit was approximately 1.8 million Euro. Material costs accounted for 67%, personnel costs for 17%, equipment costs for 14% and premises costs for 2% of this. The most expensive products were endografting of aortic aneurysms, with a mean price of 5291 Euro and embolizations of cerebral aneurysms (4472 Euro). Endografts formed 87.3% of the total costs in endografting and Guglielmi detachable coils accounted for 63.3% of the total costs in embolizations. The material costs formed the majority of the costs, especially in the newest and most complicated endovascular treatments. Despite the high cost of angiography equipment, its share of the costs is minor. In our experience ABC system is suitable for analysing costs in interventional radiology. (orig.)

  7. Waste Feed Delivery System Phase 1 Preliminary RAM Analysis

    International Nuclear Information System (INIS)

    DYKES, A.A.

    2000-01-01

    This report presents the updated results of the preliminary reliability, availability, and maintainability (RAM) analysis of selected waste feed delivery (WFD) operations to be performed by the Tank Farm Contractor (TFC) during Phase I activities in support of the Waste Treatment and Immobilization Plant (WTP). For planning purposes, waste feed tanks are being divided into five classes in accordance with the type of waste in each tank and the activities required to retrieve, qualify, and transfer waste feed. This report reflects the baseline design and operating concept, as of the beginning of Fiscal Year 2000, for the delivery of feed from three of these classes, represented by source tanks 241-AN-102, 241-AZ-101 and 241-AN-105. The preliminary RAM analysis quantifies the potential schedule delay associated with operations and maintenance (OBM) field activities needed to accomplish these operations. The RAM analysis is preliminary because the system design, process definition, and activity planning are in a state of evolution. The results are being used to support the continuing development of an O and M Concept tailored to the unique requirements of the WFD Program, which is being documented in various volumes of the Waste Feed Delivery Technical Basis (Carlson. 1999, Rasmussen 1999, and Orme 2000). The waste feed provided to the WTP must: (1) meet limits for chemical and radioactive constituents based on pre-established compositional envelopes (i.e., feed quality); (2) be in acceptable quantities within a prescribed sequence to meet feed quantities; and (3) meet schedule requirements (i.e., feed timing). In the absence of new criteria related to acceptable schedule performance due to the termination of the TWRS Privatization Contract, the original criteria from the Tank Waste Remediation System (77443s) Privatization Contract (DOE 1998) will continue to be used for this analysis

  8. Preliminary assessment of the radiological impact for individual waste management areas at the Oak Ridge National Laboratory: Status report

    International Nuclear Information System (INIS)

    Sears, M.B.

    1987-09-01

    This study estimates the radiological impact (i.e., the potential doses) for individual waste management areas at the Oak Ridge National Laboratory and ranks the areas for remedial action based on the off-site doses that result from these discharges to White Oak Creek. Dose estimates are given for the drinking water pathway based on known discharges from White Oak Dam. Estimates are also made of doses for eating fish caught in the Clinch River near the confluence with White Oak Creek. The results of a search for data concerning the discharges of 90 Sr, 3 H, 137 Cs, and 60 Co from individual waste management areas are presented. A qualitative assessment is presented, and areas are ranked for remedial investigation based on the available information. 29 refs., 8 figs., 45 tabs

  9. Radiology resident MR and CT image analysis skill assessment using an interactive volumetric simulation tool - the RadioLOG project

    International Nuclear Information System (INIS)

    Gondim Teixeira, Pedro Augusto; Leplat, Christophe; Cendre, Romain; Hossu, Gabriela; Felblinger, Jacques; Blum, Alain; Braun, Marc

    2017-01-01

    Assess the use of a volumetric simulation tool for the evaluation of radiology resident MR and CT interpretation skills. Forty-three participants were evaluated with a software allowing the visualisation of multiple volumetric image series. There were 7 medical students, 28 residents and 8 senior radiologists among the participants. Residents were divided into two sub-groups (novice and advanced). The test was composed of 15 exercises on general radiology and lasted 45 min. Participants answered a questionnaire on their experience with the test using a 5-point Likert scale. This study was approved by the dean of the medical school and did not require ethics committee approval. The reliability of the test was good with a Cronbach alpha value of 0.9. Test scores were significantly different in all sub-groups studies (p < 0.0225). The relation between test scores and the year of residency was logarithmic (R"2 = 0.974). Participants agreed that the test reflected their radiological practice (3.9 ± 0.9 on a 5-point scale) and was better than the conventional evaluation methods (4.6 ± 0.5 on a 5-point scale). This software provides a high quality evaluation tool for the assessment of the interpretation skills in radiology residents. (orig.)

  10. Radiology resident MR and CT image analysis skill assessment using an interactive volumetric simulation tool - the RadioLOG project

    Energy Technology Data Exchange (ETDEWEB)

    Gondim Teixeira, Pedro Augusto; Leplat, Christophe [CHRU-Nancy Hopital Central, Service d' Imagerie Guilloz, Nancy (France); Universite de Lorraine, IADI U947, Nancy (France); Cendre, Romain [INSERM, CIC-IT 1433, Nancy (France); Hossu, Gabriela; Felblinger, Jacques [Universite de Lorraine, IADI U947, Nancy (France); INSERM, CIC-IT 1433, Nancy (France); Blum, Alain [CHRU-Nancy Hopital Central, Service d' Imagerie Guilloz, Nancy (France); Braun, Marc [CHRU-Nancy Hopital Central, Service de Neuroradiologie, Nancy (France)

    2017-02-15

    Assess the use of a volumetric simulation tool for the evaluation of radiology resident MR and CT interpretation skills. Forty-three participants were evaluated with a software allowing the visualisation of multiple volumetric image series. There were 7 medical students, 28 residents and 8 senior radiologists among the participants. Residents were divided into two sub-groups (novice and advanced). The test was composed of 15 exercises on general radiology and lasted 45 min. Participants answered a questionnaire on their experience with the test using a 5-point Likert scale. This study was approved by the dean of the medical school and did not require ethics committee approval. The reliability of the test was good with a Cronbach alpha value of 0.9. Test scores were significantly different in all sub-groups studies (p < 0.0225). The relation between test scores and the year of residency was logarithmic (R{sup 2} = 0.974). Participants agreed that the test reflected their radiological practice (3.9 ± 0.9 on a 5-point scale) and was better than the conventional evaluation methods (4.6 ± 0.5 on a 5-point scale). This software provides a high quality evaluation tool for the assessment of the interpretation skills in radiology residents. (orig.)

  11. Radiological consequence analysis for upgradation of Pakistan Research Reactor-1 from 9 to 10 MW

    International Nuclear Information System (INIS)

    Khan, L.A.; Raza, S.S.

    1993-12-01

    Radiological consequence analysis has been carried out for upgradation of PARR-I from 9 to 10 MW. A hypothetical loss of coolant accident resulting in core meltdown and release of fission products to the atmosphere has been analyzed. Whole body and thyroid doses have been calculated as a function of time and distance from the containment building. Based on these dose estimates, boundaries of exclusion and low population zones are assessed. (author)

  12. Multi-criteria analysis for evaluating the radiological and ecological safety measures in radioactive waste management

    International Nuclear Information System (INIS)

    Sazykina, T.G.; Kryshev, I.I.

    2006-01-01

    A methodological approach is presented for multicriterial evaluating the effectiveness of radiation ecological safety measures during radioactive waste management. The approach is based on multicriterial analysis with consideration of radiological, ecological, social, economical consequences of various safety measures. The application of the multicriterial approach is demonstrated taking as an example of decision-making on the most effective actions for rehabilitation of a water subject, contaminated with radionuclides [ru

  13. Offsite radiological consequence analysis for the bounding aircraft crash accident

    International Nuclear Information System (INIS)

    OBERG, B.D.

    2003-01-01

    The purpose of this calculation note is to quantitatively analyze a bounding aircraft crash accident for comparison to the DOE-STD-3009-94, ''Preparation Guide for U.S. Department of Energy Nonreactor Nuclear Facility Documented Safety Analyses'', Appendix A, Evaluation Guideline of 25 rem. The potential of aircraft impacting a facility was evaluated using the approach given in DOE-STD-3014-96, ''Accident Analysis for Aircraft Crash into Hazardous Facilities''. The following aircraft crash FR-equencies were determined for the Tank Farms in RPP-11736, ''Assessment Of Aircraft Crash FR-equency For The Hanford Site 200 Area Tank Farms'': (1) The total aircraft crash FR-equency is ''extremely unlikely.'' (2) The general aviation crash FR-equency is ''extremely unlikely.'' (3) The helicopter crash FR-equency is ''beyond extremely unlikely.'' (4) For the Hanford Site 200 Areas, other aircraft type, commercial or military, each above ground facility, and any other type of underground facility is ''beyond extremely unlikely.'' As the potential of aircraft crash into the 200 Area tank farms is more FR-equent than ''beyond extremely unlikely,'' consequence analysis of the aircraft crash is required

  14. Evaluating two-dimensional skeletal structure parameters using radiological bone morphometric analysis

    International Nuclear Information System (INIS)

    Asa, Kensuke; Sakurai, Takashi; Kashima, Isamu; Kumasaka, Satsuki

    2005-01-01

    The objectives of this study was to investigate the reliability of two-dimensional (2D) skeletal structure parameters obtained using radiological bone morphometric analysis. The 2D skeletal parameters in the regions of interest (ROIs) were measured on computed radiography (CR) images of first phalanges from racehorses, using radiological bone morphometric analysis. Cancellous bone blocks were made from the phalanges in the same position as the ROI determined on CR images. Three-dimensional (3D) trabecular parameters were measured using micro-computed tomography (μCT). The correlations between the 2D skeletal parameters and 3D trabecular parameters were evaluated in relation to the measured bone strength. The following 2D skeletal structure parameters were correlated with bone strength (r=0.61-0.69): skeletal perimeter (Sk.Pm), skeletal number (Sk.N), skeletal separation (Sk.Sp), skeletal spacing (Sk.Spac), fractal dimension (FD), and skeletal pattern factor (SkPf). The 3D trabecular structure parameters were closely correlated with bone strength (r=0.74-0.86). The 2D skeletal parameters Sk.N, Sk.Pm, FD, SkPf, and Sk.Spac were correlated with the 3D trabecular parameters (r=0.61-0.70). The 2D skeletal parameters obtained using radiological bone morphometric analysis may be useful indicators of trabecular strength. (author)

  15. Improving financial performance by modeling and analysis of radiology procedure scheduling at a large community hospital.

    Science.gov (United States)

    Lu, Lingbo; Li, Jingshan; Gisler, Paula

    2011-06-01

    Radiology tests, such as MRI, CT-scan, X-ray and ultrasound, are cost intensive and insurance pre-approvals are necessary to get reimbursement. In some cases, tests may be denied for payments by insurance companies due to lack of pre-approvals, inaccurate or missing necessary information. This can lead to substantial revenue losses for the hospital. In this paper, we present a simulation study of a centralized scheduling process for outpatient radiology tests at a large community hospital (Central Baptist Hospital in Lexington, Kentucky). Based on analysis of the central scheduling process, a simulation model of information flow in the process has been developed. Using such a model, the root causes of financial losses associated with errors and omissions in this process were identified and analyzed, and their impacts were quantified. In addition, "what-if" analysis was conducted to identify potential process improvement strategies in the form of recommendations to the hospital leadership. Such a model provides a quantitative tool for continuous improvement and process control in radiology outpatient test scheduling process to reduce financial losses associated with process error. This method of analysis is also applicable to other departments in the hospital.

  16. Cost analysis of operating an all-digital radiology department

    International Nuclear Information System (INIS)

    Arenson, R.L.; Soshadri, S.B.; DeSimone, D.; Hiss, S.S.

    1988-01-01

    Using the current film system as a baseline, this study analyzes the cost of digital acquisition, transmission, archiving, and display of all images generated in our department. Two approaches are considered: (1) conventional x-ray films are digitized with a laser scanning film digitizer; (2) images are captured with a direct digital receptor and no film is created. In both approaches, images from digital modalities are acquired directly from the scanners. The cost of equipment and its maintenance, film, supplies, storage space, operations, personnel, and so forth are analyzed for all approaches. The annual cost of operating the film system is $2.5 million. The estimated annual cost is $2.3 million for the first digital approach, $1.8 million for the second. This analysis demonstrates that these digital approaches can be cost-effective, viable alternatives to film-bases systems

  17. Preliminary analysis of a target factory for laser fusion

    International Nuclear Information System (INIS)

    Sherohman, J.W.; Hendricks, C.D.

    1980-01-01

    An analysis of a target factory leading to the determination of production expressions has provided for the basis of a parametric study. Parameters involving the input and output rate of a process system, processing yield factors, and multiple processing steps and production lines have been used to develop an understanding of their dependence on the rate of target injection for laser fusion. Preliminary results have indicated that a parametric study of this type will be important in the selection of processing methods to be used in the final production scheme of a target factory

  18. Determinants of Trade Credit: A Preliminary Analysis on Construction Sector

    Directory of Open Access Journals (Sweden)

    Nicoleta Barbuta-Misu

    2016-07-01

    Full Text Available This paper introduces a preliminary analysis of the correlations between trade credit and some selected measures of financial performance for a sample of 958 firms acting in the construction sector. The examined period covers 2004-2013. The sample derived from Amadeus database contains firms that have sold and bought on credit. Results showed that larger firms offered and used more credit than counterparties. Firms offered and used in same time credit, but not in same level. Firms with higher return on assets and profit margin used and offered less credit from suppliers, respectively to clients. Moreover, more liquid firms used less trade payables.

  19. Capture and analysis of radiation dose reports for radiology

    International Nuclear Information System (INIS)

    Midgley, S.M.

    2014-01-01

    Radiographic imaging systems can produce records of exposure and dose parameters for each patient. A variety of file formats are in use including plain text, bit map images showing pictures of written text and radiation dose structured reports as text or extended markup language files. Whilst some of this information is available with image data on the hospital picture archive and communication system, access is restricted to individual patient records, thereby making it difficult to locate multiple records for the same scan protocol. This study considers the exposure records and dose reports from four modalities. Exposure records for mammography and general radiography are utilized for repeat analysis. Dose reports for fluoroscopy and computed tomography (CT) are utilized to study the distribution of patient doses for each protocol. Results for dosimetric quantities measured by General Radiography, Fluoroscopy and CT equipment are summarised and presented in the Appendix. Projection imaging uses the dose (in air) area product and derived quantities including the dose to the reference point as a measure of the air kerma reaching the skin, ignoring movement of the beam for fluoroscopy. CT uses the dose indices CTDIvol and dose length product as a measure of the dose per axial slice, and to the scanned volume. Suitable conversion factors are identified and used to estimate the effective dose to an average size patient (for CT and fluoroscopy) and the entrance skin dose for fluoroscopy.

  20. Development of an auditable safety analysis in support of a radiological facility classification

    International Nuclear Information System (INIS)

    Kinney, M.D.; Young, B.

    1995-01-01

    In recent years, U.S. Department of Energy (DOE) facilities commonly have been classified as reactor, non-reactor nuclear, or nuclear facilities. Safety analysis documentation was prepared for these facilities, with few exceptions, using the requirements in either DOE Order 5481.1B, Safety Analysis and Review System; or DOE Order 5480.23, Nuclear Safety Analysis Reports. Traditionally, this has been accomplished by development of an extensive Safety Analysis Report (SAR), which identifies hazards, assesses risks of facility operation, describes and analyzes adequacy of measures taken to control hazards, and evaluates potential accidents and their associated risks. This process is complicated by analysis of secondary hazards and adequacy of backup (redundant) systems. The traditional SAR process is advantageous for DOE facilities with appreciable hazards or operational risks. SAR preparation for a low-risk facility or process can be cost-prohibitive and quite challenging because conventional safety analysis protocols may not readily be applied to a low-risk facility. The DOE Office of Environmental Restoration and Waste Management recognized this potential disadvantage and issued an EM limited technical standard, No. 5502-94, Hazard Baseline Documentation. This standard can be used for developing documentation for a facility classified as radiological, including preparation of an auditable (defensible) safety analysis. In support of the radiological facility classification process, the Uranium Mill Tailings Remedial Action (UMTRA) Project has developed an auditable safety analysis document based upon the postulation criteria and hazards analysis techniques defined in DOE Order 5480.23

  1. Modeling and Analysis on Radiological Safety Assessment of Low- and Intermediate Level Radioactive Waste Repository

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Youn Myoung; Jung, Jong Tae; Kang, Chul Hyung (and others)

    2008-04-15

    Modeling study and analysis for technical support for the safety and performance assessment of the low- and intermediate level (LILW) repository partially needed for radiological environmental impact reporting which is essential for the licenses for construction and operation of LILW has been fulfilled. Throughout this study such essential area for technical support for safety and performance assessment of the LILW repository and its licensing as gas generation and migration in and around the repository, risk analysis and environmental impact during transportation of LILW, biosphere modeling and assessment for the flux-to-dose conversion factors for human exposure as well as regional and global groundwater modeling and analysis has been carried out.

  2. Modeling and Analysis on Radiological Safety Assessment of Low- and Intermediate Level Radioactive Waste Repository

    International Nuclear Information System (INIS)

    Lee, Youn Myoung; Jung, Jong Tae; Kang, Chul Hyung

    2008-04-01

    Modeling study and analysis for technical support for the safety and performance assessment of the low- and intermediate level (LILW) repository partially needed for radiological environmental impact reporting which is essential for the licenses for construction and operation of LILW has been fulfilled. Throughout this study such essential area for technical support for safety and performance assessment of the LILW repository and its licensing as gas generation and migration in and around the repository, risk analysis and environmental impact during transportation of LILW, biosphere modeling and assessment for the flux-to-dose conversion factors for human exposure as well as regional and global groundwater modeling and analysis has been carried out

  3. CONTENT ANALYSIS, DISCOURSE ANALYSIS, AND CONVERSATION ANALYSIS: PRELIMINARY STUDY ON CONCEPTUAL AND THEORETICAL METHODOLOGICAL DIFFERENCES

    Directory of Open Access Journals (Sweden)

    Anderson Tiago Peixoto Gonçalves

    2016-08-01

    Full Text Available This theoretical essay aims to reflect on three models of text interpretation used in qualitative research, which is often confused in its concepts and methodologies (Content Analysis, Discourse Analysis, and Conversation Analysis. After the presentation of the concepts, the essay proposes a preliminary discussion on conceptual and theoretical methodological differences perceived between them. A review of the literature was performed to support the conceptual and theoretical methodological discussion. It could be verified that the models have differences related to the type of strategy used in the treatment of texts, the type of approach, and the appropriate theoretical position.

  4. Sedation for pediatric radiological procedures: analysis of potential causes of sedation failure and paradoxical reactions

    Energy Technology Data Exchange (ETDEWEB)

    Karian, V.E.; Burrows, P.E.; Connor, L. [Dept. of Radiology, Children' s Hospital, Boston, MA (United States); Zurakowski, D. [Dept. of Biostatistics, Children' s Hospital, Boston, MA (United States); Mason, K.P. [Dept. of Anesthesiology, Children' s Hospital, Boston, MA (United States)

    1999-11-01

    Background. Sedation for diagnostic imaging and interventional radiologic procedures in pediatrics has greatly increased over the past decade. With appropriate patient selection and monitoring, serious adverse effects are infrequent, but failure to sedate and paradoxical reactions do occur. Objective. The purpose of this study was to determine, among patients undergoing sedation for radiologic procedures, the incidence of sedation failure and paradoxical reaction to pentobarbital and to identify potentially correctable causes. Materials and methods. Records of 1665 patients who were sedated in the radiology department from 1 November 1997 to 1 July 1998 were reviewed. Patients failing sedation or experiencing paradoxical reaction were compared with respect to sex, age group, diagnosis, scan type, time of day, NPO status, use of IV contrast and type of sedation agent using the Fisher exact test, Pearson chi-square, analysis of variance (ANOVA), the Student t-test, and logistic regression. Results. Data analysis revealed a sedation failure rate of 1 % and paradoxical reaction rate of 1.2 %. Stepwise multiple logistic regression revealed that the only significant independent multivariate predictor of failure was the need for the administration of a combination of pentobarbital, fentanyl, and midazolam IV. Conclusion. The low rate of sedation failure and paradoxical reactions to pentobarbital was near optimal and probably cannot be improved with the currently available sedatives. (orig.)

  5. Sedation for pediatric radiological procedures: analysis of potential causes of sedation failure and paradoxical reactions

    International Nuclear Information System (INIS)

    Karian, V.E.; Burrows, P.E.; Connor, L.; Zurakowski, D.; Mason, K.P.

    1999-01-01

    Background. Sedation for diagnostic imaging and interventional radiologic procedures in pediatrics has greatly increased over the past decade. With appropriate patient selection and monitoring, serious adverse effects are infrequent, but failure to sedate and paradoxical reactions do occur. Objective. The purpose of this study was to determine, among patients undergoing sedation for radiologic procedures, the incidence of sedation failure and paradoxical reaction to pentobarbital and to identify potentially correctable causes. Materials and methods. Records of 1665 patients who were sedated in the radiology department from 1 November 1997 to 1 July 1998 were reviewed. Patients failing sedation or experiencing paradoxical reaction were compared with respect to sex, age group, diagnosis, scan type, time of day, NPO status, use of IV contrast and type of sedation agent using the Fisher exact test, Pearson chi-square, analysis of variance (ANOVA), the Student t-test, and logistic regression. Results. Data analysis revealed a sedation failure rate of 1 % and paradoxical reaction rate of 1.2 %. Stepwise multiple logistic regression revealed that the only significant independent multivariate predictor of failure was the need for the administration of a combination of pentobarbital, fentanyl, and midazolam IV. Conclusion. The low rate of sedation failure and paradoxical reactions to pentobarbital was near optimal and probably cannot be improved with the currently available sedatives. (orig.)

  6. Application of failure mode and effect analysis in a radiology department.

    Science.gov (United States)

    Thornton, Eavan; Brook, Olga R; Mendiratta-Lala, Mishal; Hallett, Donna T; Kruskal, Jonathan B

    2011-01-01

    With increasing deployment, complexity, and sophistication of equipment and related processes within the clinical imaging environment, system failures are more likely to occur. These failures may have varying effects on the patient, ranging from no harm to devastating harm. Failure mode and effect analysis (FMEA) is a tool that permits the proactive identification of possible failures in complex processes and provides a basis for continuous improvement. This overview of the basic principles and methodology of FMEA provides an explanation of how FMEA can be applied to clinical operations in a radiology department to reduce, predict, or prevent errors. The six sequential steps in the FMEA process are explained, and clinical magnetic resonance imaging services are used as an example for which FMEA is particularly applicable. A modified version of traditional FMEA called Healthcare Failure Mode and Effect Analysis, which was introduced by the U.S. Department of Veterans Affairs National Center for Patient Safety, is briefly reviewed. In conclusion, FMEA is an effective and reliable method to proactively examine complex processes in the radiology department. FMEA can be used to highlight the high-risk subprocesses and allows these to be targeted to minimize the future occurrence of failures, thus improving patient safety and streamlining the efficiency of the radiology department. RSNA, 2010

  7. Cost analysis in interventional radiology-A tool to optimize management costs

    International Nuclear Information System (INIS)

    Clevert, D.-A.; Stickel, M.; Jung, E.M.; Reiser, M.; Rupp, N.

    2007-01-01

    Objective: The objective of the study was to analyze the methods to reduce cost in interventional radiology departments by reorganizing procurement. Materials and methods: All products used in Department of Interventional Radiology were inventoried. An ABC-analysis was completed and A-products (high-value and high turnover products) underwent a XYZ-analysis which predicted demand on the basis of ordering frequency. Then criteria for a procurement strategy for the different material categories were fixed. The net working capital (NWC) was calculated using an interest rate of 8%/year. Results: Total annual material turnover was 353,000 Euro . The value of all A-products determined by the inventory was 260,000 Euro . Changes in the A-product procurement strategy tapped a cost reduction potential of 14,500/year Euro . The resulting total saving was 17,200 Euro . Improved stores management added another 37,500 Euro. The total cost cut of 52,000 Euro is equivalent to 14.7% of annual expenses. Conclusion: A flexible procurement strategy helps to reduce the storage and capital tie-up costs of A-products in interventional radiology without affecting the quality of service provided to patients

  8. A preliminary study into performing routine tube output and automatic exposure control quality assurance using radiology information system data

    International Nuclear Information System (INIS)

    Charnock, P.; Jones, R.; Fazakerley, J.; Wilde, R.; Dunn, A. F.

    2011-01-01

    Data are currently being collected from hospital radiology information systems in the North West of the UK for the purposes of both clinical audit and patient dose audit. Could these data also be used to satisfy quality assurance (QA) requirements according to UK guidance? From 2008 to 2009, 731 653 records were submitted from 8 hospitals from the North West England. For automatic exposure control QA, the protocol from Inst. of Physics and Engineering in Medicine (IPEM) report 91 recommends that milli amperes per second can be monitored for repeatability and reproducibility using a suitable phantom, at 70-81 kV. Abdomen AP and chest PA examinations were analysed to find the most common kilo voltage used with these records then used to plot average monthly milli amperes per second with time. IPEM report 91 also recommends that a range of commonly used clinical settings is used to check output reproducibility and repeatability. For each tube, the dose area product values were plotted over time for two most common exposure factor sets. Results show that it is possible to do performance checks of AEC systems; however more work is required to be able to monitor tube output performance. Procedurally, the management system requires work and the benefits to the workflow would need to be demonstrated. (authors)

  9. An analysis on the satisfaction of radiology students with their major

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Hoon; Kang, Se Sik; Kim, Chang Soo [Dept. of Radiological Science, College of Health Sciences, Catholic University of Pusan, Busan (Korea, Republic of)

    2016-06-15

    This study was conducted with a goal to identify the factors that determine radiology students' satisfaction with their major and to provide the basic data for efficient education and career guidance. The result indicated that the students' satisfaction with the professors' roles was high. However, overall, the level of satisfaction with the curriculum was found to be low. In addition, it was analyzed that there was a large gap between recognition and practice of self-directed learning. In the correlation analysis, the professors' roles were also found to be a very important factor. Based on the result, the professors' roles of center(teaching or state examination, students with questions etc.,), it was concluded that improvement of the radiology students' satisfaction with their major would help the students adapt themselves to the major and school successfully and develop a positive character to perform as professionals in the future.

  10. An analysis on the satisfaction of radiology students with their major

    International Nuclear Information System (INIS)

    Kim, Jung Hoon; Kang, Se Sik; Kim, Chang Soo

    2016-01-01

    This study was conducted with a goal to identify the factors that determine radiology students' satisfaction with their major and to provide the basic data for efficient education and career guidance. The result indicated that the students' satisfaction with the professors' roles was high. However, overall, the level of satisfaction with the curriculum was found to be low. In addition, it was analyzed that there was a large gap between recognition and practice of self-directed learning. In the correlation analysis, the professors' roles were also found to be a very important factor. Based on the result, the professors' roles of center(teaching or state examination, students with questions etc.,), it was concluded that improvement of the radiology students' satisfaction with their major would help the students adapt themselves to the major and school successfully and develop a positive character to perform as professionals in the future

  11. Analysis of the effect of variations in parameter values on the predicted radiological consequences of geologic disposal of high-level waste

    International Nuclear Information System (INIS)

    Hill, M.D.

    1979-06-01

    A preliminary assessment of the radiological consequences of geologic disposal of high-level waste (Hill and Grimwood. NRPB-R69 (1978)) identified several areas where further research is required before this disposal option can be fully evaluated. This report is an analysis of the sensitivity of the results of the preliminary assessment to the assumptions made and the values of the parameters used. The parameters considered include the leach rate of the waste, the ground-water velocity, the length of the flow path from the repository to a source of drinking water and the sorption constants of the principle radionuclides. The results obtained by varying these parameters are used to examine the effects of assumptions such as the time at which leaching of the waste begins. The sensitivity analysis shows the relative importance of the waste canisters, the waste form and the geologic barrier to radionuclide migration in determining potential doses. These results are used to identify research priorities, establish preliminary design criteria and indicate developments needed in the mathematical modelling of the movement of radionuclides from a repository to the biosphere. (author)

  12. Enhanced Accident Tolerant Fuels for LWRS - A Preliminary Systems Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Gilles Youinou; R. Sonat Sen

    2013-09-01

    The severe accident at Fukushima Daiichi nuclear plants illustrates the need for continuous improvements through developing and implementing technologies that contribute to safe, reliable and cost-effective operation of the nuclear fleet. Development of enhanced accident tolerant fuel contributes to this effort. These fuels, in comparison with the standard zircaloy – UO2 system currently used by the LWR industry, should be designed such that they tolerate loss of active cooling in the core for a longer time period (depending on the LWR system and accident scenario) while maintaining or improving the fuel performance during normal operations, operational transients, and design-basis events. This report presents a preliminary systems analysis related to most of these concepts. The potential impacts of these innovative LWR fuels on the front-end of the fuel cycle, on the reactor operation and on the back-end of the fuel cycle are succinctly described without having the pretension of being exhaustive. Since the design of these various concepts is still a work in progress, this analysis can only be preliminary and could be updated as the designs converge on their respective final version.

  13. Preliminary hazards analysis of thermal scrap stabilization system. Revision 1

    International Nuclear Information System (INIS)

    Lewis, W.S.

    1994-01-01

    This preliminary analysis examined the HA-21I glovebox and its supporting systems for potential process hazards. Upon further analysis, the thermal stabilization system has been installed in gloveboxes HC-21A and HC-21C. The use of HC-21C and HC-21A simplified the initial safety analysis. In addition, these gloveboxes were cleaner and required less modification for operation than glovebox HA-21I. While this document refers to glovebox HA-21I for the hazards analysis performed, glovebox HC-21C is sufficiently similar that the following analysis is also valid for HC-21C. This hazards analysis document is being re-released as revision 1 to include the updated flowsheet document (Appendix C) and the updated design basis (Appendix D). The revised Process Flow Schematic has also been included (Appendix E). This Current revision incorporates the recommendations provided from the original hazards analysis as well. The System Design Description (SDD) has also been appended (Appendix H) to document the bases for Safety Classification of thermal stabilization equipment

  14. Analysis preliminary phytochemical raw extract of leaves Nephrolepis pectinata

    Directory of Open Access Journals (Sweden)

    Natally Marreiros Gomes

    2017-06-01

    Full Text Available The Nephrolepis pectinata popularly known as paulista fern, ladder-heaven, cat tail, belongs to the family Davalliaceae. For the beauty of the arrangements of their leaves ferns are quite commercialized in Brazil, however, have not been described in the literature studies on their pharmacological potential. Thus, the objective of this research was to analyze the phytochemical properties of the crude extract of the leaves of Nephrolepis pectinata. To perform the phytochemical analysis were initially made the collection of the vegetable, preparation of voucher specimen, washing, drying and grinding. Then, extraction by percolation method and end the phytochemical analysis. Preliminary results phytochemicals the crude extract of the leaves of Nephrolepis pectinata tested positive for reducing sugars, phenols/tannins (catechins tannins and catechins.

  15. Preliminary analysis of accident in SST-1 current feeder system

    International Nuclear Information System (INIS)

    Roy, Swati; Kanabar, Deven; Garg, Atul; Singh, Amit; Tanna, Vipul; Prasad, Upendra; Srinivasan, R.

    2017-01-01

    Steady-state Tokamak-1 (SST-1) has 16 superconducting Toroidal field (TF) and 9 superconducting poloidal field (PF) coils rated for 10kA DC. All the TF are connected in series and are operated in DC condition whereas PF coils are individually operated in pulse mode during SST-1 campaigns. SST-1 current feeder system (CFS) houses 9 pairs of PF current leads and 1 pair of TF current leads. During past SST-1 campaign, there were arcing incidents within SST-1 CFS chamber which caused significant damage to PF superconducting current leads as well as its Helium cooling lines of the current leads. This paper brings out the preliminary analysis of the mentioned arcing incident, possible reasons and its investigation thereby laying out the sequence of events. From this analysis and observations, various measures to avoid such arcing incidents have also been proposed. (author)

  16. Women authorship in radiology research in France: An analysis of the last three decades.

    Science.gov (United States)

    Pyatigorskaya, N; Di Marco, L

    2017-11-01

    The aim of this study was to evaluate the evolution of women authorship in France and to analyze the recent trends of the evolution of gender differences in French academic radiology. A retrospective bibliometric analysis was performed by searching for articles published in Diagnostic and Interventional Imaging (Diagn Interv Imaging) and in Journal de Radiologie (J Radiol) in Pubmed over the last three decades. For each of these articles, we determined the gender of the first and last author. The specific radiological field of each article was also determined. The proportion of women authors has significantly increased from 12% in 1984 to 34% in 2014 (Pauthorship in Diagnostic and Interventional Imaging has increased over the last years together with the proportion of women first authors. However, the fraction of women last authors is still underrepresented. More women need to become leaders in radiological research to contribute to stimulate women authorship. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  17. Radiological Safety Analysis Computer (RSAC) Program Version 7.0 Users’ Manual

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Bradley J Schrader

    2009-03-01

    The Radiological Safety Analysis Computer (RSAC) Program Version 7.0 (RSAC-7) is the newest version of the RSAC legacy code. It calculates the consequences of a release of radionuclides to the atmosphere. A user can generate a fission product inventory from either reactor operating history or a nuclear criticality event. RSAC-7 models the effects of high-efficiency particulate air filters or other cleanup systems and calculates the decay and ingrowth during transport through processes, facilities, and the environment. Doses are calculated for inhalation, air immersion, ground surface, ingestion, and cloud gamma pathways. RSAC-7 can be used as a tool to evaluate accident conditions in emergency response scenarios, radiological sabotage events and to evaluate safety basis accident consequences. This users’ manual contains the mathematical models and operating instructions for RSAC-7. Instructions, screens, and examples are provided to guide the user through the functions provided by RSAC-7. This program was designed for users who are familiar with radiological dose assessment methods.

  18. Radiological Safety Analysis Computer (RSAC) Program Version 7.2 Users’ Manual

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Bradley J Schrader

    2010-10-01

    The Radiological Safety Analysis Computer (RSAC) Program Version 7.2 (RSAC-7) is the newest version of the RSAC legacy code. It calculates the consequences of a release of radionuclides to the atmosphere. A user can generate a fission product inventory from either reactor operating history or a nuclear criticality event. RSAC-7 models the effects of high-efficiency particulate air filters or other cleanup systems and calculates the decay and ingrowth during transport through processes, facilities, and the environment. Doses are calculated for inhalation, air immersion, ground surface, ingestion, and cloud gamma pathways. RSAC-7 can be used as a tool to evaluate accident conditions in emergency response scenarios, radiological sabotage events and to evaluate safety basis accident consequences. This users’ manual contains the mathematical models and operating instructions for RSAC-7. Instructions, screens, and examples are provided to guide the user through the functions provided by RSAC-7. This program was designed for users who are familiar with radiological dose assessment methods.

  19. Radiological Safety Analysis Computer (RSAC) Program Version 7.0 Users Manual

    International Nuclear Information System (INIS)

    Schrader, Bradley J.

    2009-01-01

    The Radiological Safety Analysis Computer (RSAC) Program Version 7.0 (RSAC-7) is the newest version of the RSAC legacy code. It calculates the consequences of a release of radionuclides to the atmosphere. A user can generate a fission product inventory from either reactor operating history or a nuclear criticality event. RSAC-7 models the effects of high-efficiency particulate air filters or other cleanup systems and calculates the decay and ingrowth during transport through processes, facilities, and the environment. Doses are calculated for inhalation, air immersion, ground surface, ingestion, and cloud gamma pathways. RSAC-7 can be used as a tool to evaluate accident conditions in emergency response scenarios, radiological sabotage events and to evaluate safety basis accident consequences. This users manual contains the mathematical models and operating instructions for RSAC-7. Instructions, screens, and examples are provided to guide the user through the functions provided by RSAC-7. This program was designed for users who are familiar with radiological dose assessment methods

  20. Analysis of data related to the updating of diagnosis reference levels in radiology and nuclear medicine. Assessment 2007-2008

    International Nuclear Information System (INIS)

    2010-01-01

    This report presents the results of the analysis of 'patient' dosimetric data which radiology and nuclear medicine establishments must supply every year to the IRSN (the French Radioprotection and Nuclear Safety Institute) according to a decree related to diagnosis reference levels in radiology and nuclear medicine. The analysed dosimetric data concern assessments performed during 2007 and 2008. For the different concerned practices (radiology, scanography, nuclear medicine), the report proposes a presentation and a discussion of global data, and then a presentation of data either for different types of examination on adults and on children, or for the different parts of the body

  1. Preliminary RAMI analysis of WCLL blanket and breeder systems

    International Nuclear Information System (INIS)

    Arroyo, Jose Manuel; Brown, Richard; Harman, Jon; Rosa, Elena; Ibarra, Angel

    2015-01-01

    Highlights: • Preliminary RAMI model for WCLL has been developed. • Critical parts and parameters influencing WCLL availability have been focused. • Necessary developments of tools/models to represent system performance have been identified. - Abstract: DEMO will be a prototype fusion reactor designed to prove the capability to produce electrical power in a commercially acceptable way. One of the key factors in that endeavor is the achievement of certain level of plant availability. Therefore, RAMI (Reliability, Availability, Maintainability and Inspectability) will be a key element in the engineering development of DEMO. Some studies have been started so as to develop the tools and models to assess different design alternatives from RAMI point of view. The main objective of these studies is to be able to evaluate the influence of different parameters on DEMO availability and to focus the critical parts that should be further researched and improved in order to develop a high-availability oriented DEMO design. A preliminary RAMI analysis of the Water Cooled Lithium-Lead (WCLL) blanket and breeder concept for DEMO has been developed. The amounts of single elements that may fail (e.g. more than 180,000 C-shaped tubes) and the mean down time associated to failures inside the vacuum vessel (around 3 months) have been highlighted as the critical parameters influencing the system availability. On the other hand, the necessary developments of tools/models to better represent the system performance have been identified and proposed for future work.

  2. Preliminary RAMI analysis of WCLL blanket and breeder systems

    Energy Technology Data Exchange (ETDEWEB)

    Arroyo, Jose Manuel, E-mail: josemanuel.arroyo@ciemat.es [Laboratorio Nacional de Fusión por Confinamiento Magnético – CIEMAT, Madrid (Spain); Brown, Richard [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon (United Kingdom); Harman, Jon [EFDA Close Support Unit, Garching (Germany); Rosa, Elena; Ibarra, Angel [Laboratorio Nacional de Fusión por Confinamiento Magnético – CIEMAT, Madrid (Spain)

    2015-10-15

    Highlights: • Preliminary RAMI model for WCLL has been developed. • Critical parts and parameters influencing WCLL availability have been focused. • Necessary developments of tools/models to represent system performance have been identified. - Abstract: DEMO will be a prototype fusion reactor designed to prove the capability to produce electrical power in a commercially acceptable way. One of the key factors in that endeavor is the achievement of certain level of plant availability. Therefore, RAMI (Reliability, Availability, Maintainability and Inspectability) will be a key element in the engineering development of DEMO. Some studies have been started so as to develop the tools and models to assess different design alternatives from RAMI point of view. The main objective of these studies is to be able to evaluate the influence of different parameters on DEMO availability and to focus the critical parts that should be further researched and improved in order to develop a high-availability oriented DEMO design. A preliminary RAMI analysis of the Water Cooled Lithium-Lead (WCLL) blanket and breeder concept for DEMO has been developed. The amounts of single elements that may fail (e.g. more than 180,000 C-shaped tubes) and the mean down time associated to failures inside the vacuum vessel (around 3 months) have been highlighted as the critical parameters influencing the system availability. On the other hand, the necessary developments of tools/models to better represent the system performance have been identified and proposed for future work.

  3. Fractal analysis in radiological and nuclear medicine perfusion imaging: a systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Michallek, Florian; Dewey, Marc [Humboldt-Universitaet zu Berlin, Freie Universitaet Berlin, Charite - Universitaetsmedizin Berlin, Medical School, Department of Radiology, Berlin (Germany)

    2014-01-15

    To provide an overview of recent research in fractal analysis of tissue perfusion imaging, using standard radiological and nuclear medicine imaging techniques including computed tomography (CT), magnetic resonance imaging (MRI), ultrasound, positron emission tomography (PET) and single-photon emission computed tomography (SPECT) and to discuss implications for different fields of application. A systematic review of fractal analysis for tissue perfusion imaging was performed by searching the databases MEDLINE (via PubMed), EMBASE (via Ovid) and ISI Web of Science. Thirty-seven eligible studies were identified. Fractal analysis was performed on perfusion imaging of tumours, lung, myocardium, kidney, skeletal muscle and cerebral diseases. Clinically, different aspects of tumour perfusion and cerebral diseases were successfully evaluated including detection and classification. In physiological settings, it was shown that perfusion under different conditions and in various organs can be properly described using fractal analysis. Fractal analysis is a suitable method for quantifying heterogeneity from radiological and nuclear medicine perfusion images under a variety of conditions and in different organs. Further research is required to exploit physiologically proven fractal behaviour in the clinical setting. (orig.)

  4. Fractal analysis in radiological and nuclear medicine perfusion imaging: a systematic review

    International Nuclear Information System (INIS)

    Michallek, Florian; Dewey, Marc

    2014-01-01

    To provide an overview of recent research in fractal analysis of tissue perfusion imaging, using standard radiological and nuclear medicine imaging techniques including computed tomography (CT), magnetic resonance imaging (MRI), ultrasound, positron emission tomography (PET) and single-photon emission computed tomography (SPECT) and to discuss implications for different fields of application. A systematic review of fractal analysis for tissue perfusion imaging was performed by searching the databases MEDLINE (via PubMed), EMBASE (via Ovid) and ISI Web of Science. Thirty-seven eligible studies were identified. Fractal analysis was performed on perfusion imaging of tumours, lung, myocardium, kidney, skeletal muscle and cerebral diseases. Clinically, different aspects of tumour perfusion and cerebral diseases were successfully evaluated including detection and classification. In physiological settings, it was shown that perfusion under different conditions and in various organs can be properly described using fractal analysis. Fractal analysis is a suitable method for quantifying heterogeneity from radiological and nuclear medicine perfusion images under a variety of conditions and in different organs. Further research is required to exploit physiologically proven fractal behaviour in the clinical setting. (orig.)

  5. A comparative cost analysis of picture archiving and communications systems (PACS versus conventional radiology in the private sector

    Directory of Open Access Journals (Sweden)

    Indres Moodley

    2015-03-01

    Aim: To undertake an incremental cost analysis of PACS compared with conventional radiology to determine productivity gains, if any, at two private hospitals in Durban. Method: An incremental cost analysis for chest radiographs, computed tomography and magnetic resonance imaging brain scans with and without contrast were performed. The overall incremental cost for PACS in comparison with a conventional radiology site was determined. The net present value was also determined to evaluate the capital budgeting requirements for both systems. Results: The incremental cost of both capital and the radiology information system for installing PACS shows an expected increase. The incremental PACS image cost shows a reduction. Conclusion: The study provides a benchmark for the cost incurred when implementing PACS. It also provides a decision framework for radiology departments that plan to introduce PACS and helps to determine the feasibility of its introduction.

  6. RSL-Nellis Analysis of Radiological Data from the Las Vegas Motor Speedway

    International Nuclear Information System (INIS)

    Wasiolek, Piotr; Okada, Colin

    2009-01-01

    The Department of Energy (DOE) National Nuclear Security Administration (NNSA) is responsible for maintaining national-level radiological emergency response assets and for deploying those assets in the event of a radiological accident or incident. NNSA's emergency response assets include the Aerial Measuring System (AMS) and Search Response Team (SRT) operated by the Remote Sensing Laboratory (RSL) located at Nellis Air Force Base, Las Vegas, Nevada and Andrews Air Force Base in Suitland, Maryland. The AMS mission is to provide a rapid response to radiological emergencies with helicopters and fixed-wing aircraft equipped to detect and measure radioactive material on the ground. The acquired data are stored and used to produce maps of radiation exposure and activity concentration per unit area. AMS also conducts surveys to create radiological baselines of major cities and nuclear facilities throughout the country. The SRT's Crisis Response (CR) mission is to provide scientific, technical, and operational support for NNSA-directed search activities involving radiological search and identification, through both field deployments and home team and reachback support. The AMS radiological mapping and SRT CR emergency response teams from the Remote Sensing Laboratory-Nellis (RSL-N) supported safety and security activities at a NASCAR race at the Las Vegas Motor Speedway (LVMS) on February 27-March 1, 2009. In support of this event, and for proficiency training, these teams carried out aerial and ground surveys of the area. The aerial radiological survey of the LVMS was conducted on February 17, 2009, and the CR ground survey was performed on February 23, 2009. RSL-N operations and appropriate law enforcement agencies selected this area as a suitable location to exercise AMS and CR capabilities for mapping environmental radiation and searching for man-made radioactive sources. The aerial surveys covered approximately 11 square miles. The survey required a 2.5-hour flight

  7. Analysis of a radiological incident and lessons to be learned: a case of industrial radiographic incident in great Britain

    International Nuclear Information System (INIS)

    Croft, J.; Lefaure, Ch.

    2000-01-01

    This note describes a case study to provide feedback analysis and lessons to be learned from a radiological incident. This one occurred in the UK. It has been published in the European ALARA Newsletter no. 2 (January 1997) and has been selected from the IRID database (Ionising Radiation Incident Database) managed by the Health and Safety Executive, National Radiological Protection Board and Environmental Agency. (authors)

  8. Repeat film analysis and its implications for quality assurance in dental radiology: An institutional case study

    Directory of Open Access Journals (Sweden)

    Shruthi Acharya

    2015-01-01

    Full Text Available Context: The goal of any radiologist is to produce the highest quality diagnostic radiographs, while keeping patient exposure as low as reasonably achievable (ALARA. Aims: The aim of this study was to describe the reasons for radiograph rejections through a repeat film analysis in an Indian dental school. Settings and Design: An observational study conducted in the Department of Oral Medicine and Radiology, Manipal College of Dental Sciences, Manipal. Materials and Methods: During a 6-month study period, a total of 9,495 intra-oral radiographs and 2339 extraoral radiographs taken in the Radiology Department were subjected to repeat film analysis. Statistical Analysis Used: SPSS Version 16. Descriptive analysis used. Results: The results showed that the repeat rates were 7.1% and 5.86% for intraoral and extraoral radiographs, respectively. Among the causes for errors reported, positioning error (38.7% was the most common, followed by improper angulations (26.1%, and improper film placement (11.2% for intra-oral radiographs. The study found that the maximum frequency of repeats among extraoral radiographs was for panoramic radiographs (49% followed by lateral cephalogram (33%, and paranasal sinus view (14%. It was also observed that repeat rate of intraoral radiographs was highest for internees (44.7%, and undergraduate students (28.2%. Conclusions: The study pointed to a need for more targeted interventions to achieve the goal of keeping patient exposure ALARA in a dental school setting.

  9. Preliminary analysis of biomass potentially useful for producing biodiesel

    International Nuclear Information System (INIS)

    Cabrera Cifuentes, Gerardo; Burbano Jaramillo, Juan Carlos; Garcia Melo, Jose Isidro

    2011-01-01

    Given that biodiesel is emerging as a viable solution for some energy and environmental problems, research on raw materials appropriate for its production is a matter of growing interest. In this study we present the results of research devoted to preliminary analysis on several vegetable (biomass) species potentially useful for producing biodiesel. The bioprospection zone is a region on the Colombian Pacific coast. The candidate species collected underwent different standardized ASTM tests in order for us to define properties that facilitate their evaluation. Some of the species underwent a transesterification process. Comparisons between the thermo-physical properties of the biofuels obtained and the properties of commercial diesel were carried out. Also, performance tests for these biofuels were conducted in compression ignition engines, particularly evaluating efficiency, fuel consumption, and potency at different RPMs.

  10. Preliminary radar systems analysis for Venus orbiter missions

    Science.gov (United States)

    Brandenburg, R. K.; Spadoni, D. J.

    1971-01-01

    A short, preliminary analysis is presented of the problems involved in mapping the surface of Venus with radar from an orbiting spacecraft. Two types of radar, the noncoherent sidelooking and the focused synthetic aperture systems, are sized to fulfill two assumed levels of Venus exploration. The two exploration levels, regional and local, assumed for this study are based on previous Astro Sciences work (Klopp 1969). The regional level is defined as 1 to 3 kilometer spatial and 0.5 to 1 km vertical resolution of 100 percent 0 of the planet's surface. The local level is defined as 100 to 200 meter spatial and 50-10 m vertical resolution of about 100 percent of the surfAce (based on the regional survey). A 10cm operating frequency was chosen for both radar systems in order to minimize the antenna size and maximize the apparent radar cross section of the surface.

  11. Radiology today

    International Nuclear Information System (INIS)

    Donner, M.W.; Heuck, F.H.W.

    1981-01-01

    The book encompasses the proceedings of a postgraduate course held in Salzburg in June 1980. 230 radiologists from 17 countries discussed here the important and practical advances of diagnostic radiology, nuclear medicine and ultrasound as they contribute to gastrointestinal, urologic, skeletal, cardiovascular, pediatric, and neuroradiology. The book contains 55 single contributions of different authors to the following main themes: Cardiovascular, Radiology, pulmonary radiology, gastrointestinal radiology, urinary tract radiology, skeletal radiology, mammography, lymphography, ultrasound, ENT radiology, and neuroradiology. (orig./MG)

  12. Analysis of radiological characteristics distribution in the vertebral bodies of the lumbosacral spine of competitive rowers

    Directory of Open Access Journals (Sweden)

    M.B. Ogurkowska

    2010-09-01

    Full Text Available Unfavorable biomechanical situations, usually related to the performance of a profession and competitive sports practice, promote formation of overloads. This problem may be particularly perceptible among sportsmen that practice strength and stamina sports. The present study deals with rowing. The purpose of this study is to evaluate the degree of degenerative changes of the lumbosacral spine in competitive rowers, on the basis of an analysis of changes in the cancellous structure of vertebral bodies. This has been achieved on the basis of radiological density acquired from a CT test.

  13. Analysis of tables, murals, grids and chassis available for conventional diagnostic radiology

    International Nuclear Information System (INIS)

    Batista, Wilson Otto; Navarro, Marcus Vinicius Teixeira

    2003-01-01

    Tables, bucky, grids, chassis and their combinations produced by several industries have been analysed, verifying and quantifying the attenuation in order to confront the results with the national and international recommendations. The results have shown that some of those tables do not satisfy the national requirements and for that reason increasing the patient dose. As the dose measurements are performed on the table or bucky, the analysis normally is not considered for quality control verifications and have to be considered, as those parts are positioned among the patient and the image receptor (radiological film) influenced the skin dose

  14. Preliminary results of standard quantitative analysis by ED-XRF

    Energy Technology Data Exchange (ETDEWEB)

    Lara, Alessandro L. de; Franca, Alana C.; Neto, Manoel R.M.; Paschuk, Sergei A., E-mail: alellara@hotmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil). Dept. de Fisica; Denyak, Valeriy, E-mail: denyak@gmail.com [Instituto de Pesquisa Pele Pequeno Principe (IPPP), Curitiba, PR (Brazil)

    2013-07-01

    A comparison between the results of elemental concentration proposed by XRS-FP software , using data obtained by EDXRF technique with those obtained by stoichiometric calculation was performed. For this purpose, five standard samples of known compounds were produced: two lead- oxide, magnesium chloride and iodine in controlled amounts. The compounds were subsequently mixed and compressed to form tablets. The samples were irradiated in three endpoints, according to an orientation. The measurements were performed at the Laboratory for Radiological UTFPR using X-123SDD the Amptek detector and X-ray tube with silver target from the same manufacturer. The operating conditions tube were 05μA current to a 40 kV voltage. Finally, the 15 spectra analyzed with the software to determine the concentration of chlorine, iodine and lead. Data from this analysis were compared with results expected in stoichiometric calculations. The data provided by the program, a convergence of results, indicating homogeneity of the samples was found. Compared to the stoichiometric calculation, a considerable discrepancy that may be the result of a misconfiguration or contamination of the sample was found. At the end, we created a proposal for continuation of the work using an auxiliary calculation should be developed in the next step.

  15. Preliminary results of standard quantitative analysis by ED-XRF

    International Nuclear Information System (INIS)

    Lara, Alessandro L. de; Franca, Alana C.; Neto, Manoel R.M.; Paschuk, Sergei A.

    2013-01-01

    A comparison between the results of elemental concentration proposed by XRS-FP software , using data obtained by EDXRF technique with those obtained by stoichiometric calculation was performed. For this purpose, five standard samples of known compounds were produced: two lead- oxide, magnesium chloride and iodine in controlled amounts. The compounds were subsequently mixed and compressed to form tablets. The samples were irradiated in three endpoints, according to an orientation. The measurements were performed at the Laboratory for Radiological UTFPR using X-123SDD the Amptek detector and X-ray tube with silver target from the same manufacturer. The operating conditions tube were 05μA current to a 40 kV voltage. Finally, the 15 spectra analyzed with the software to determine the concentration of chlorine, iodine and lead. Data from this analysis were compared with results expected in stoichiometric calculations. The data provided by the program, a convergence of results, indicating homogeneity of the samples was found. Compared to the stoichiometric calculation, a considerable discrepancy that may be the result of a misconfiguration or contamination of the sample was found. At the end, we created a proposal for continuation of the work using an auxiliary calculation should be developed in the next step

  16. Film reject analysis and image quality in diagnostic Radiology Department of a Teaching hospital in Ghana

    Directory of Open Access Journals (Sweden)

    J. Owusu-Banahene

    2014-10-01

    Full Text Available Patients usually undergo repeated X-ray examinations after their initial X-ray radiographs are rejected due to poor image quality. This subjects the patients to an excess radiation exposure and extra cost and necessitates the need to investigate the causes of reject. The use of reject analysis as part of the overall quality assurance programs in clinical radiography and radiology services is vital in the evaluation of image quality of a well-established practice. It is shown that, in spite of good quality control maintained by the Radiology Department of a Teaching hospital in Ghana, reject analysis performed on a number of radiographic films developed indicated 14.1% reject rate against 85.9% accepted films. The highest reject rate was 57.1 ± 0.7% which occurs in cervical spine and the lowest was7.7 ± 0.5% for lumbar spine. The major factors contributing to film rejection were found to be over exposure and patient positioning in cervical spine examinations. The most frequent examination was chest X-ray which accounts for about 42.2% of the total examinations. The results show low reject rates by considering the factors for radiographic rejection analysis in relation to both equipment functionality and film development in the facility.

  17. An analysis of radiological research publications in high impact general medical journals between 1996 and 2010

    International Nuclear Information System (INIS)

    Ku, You Jin; Yoon, Dae Young; Yun, Eun Joo; Baek, Sora; Lim, Kyoung Ja; Seo, Young Lan; Choi, Chul Soon; Bae, Sang Hoon

    2013-01-01

    Highlights: ► Radiologists published only 0.2% of articles in five general medical journals. ► Most original articles from radiologists were funded and were prospective studies. ► Radiology researchers from only 11 countries published at least one original article. -- Abstract: Objective: To evaluate scientific papers published by radiologists in high impact general medical journals between 1996 and 2010. Methods: A MEDLINE search was performed in five high impact general medical journals (AIM, BMJ, JAMA, Lancet, and NEJM) for all articles of which a radiologist was the first author between 1996 and 2010. The following information was abstracted from the original articles: radiological subspecialty, imaging technique used, type of research, sample size, study design, statistical analysis, study outcome, declared funding, number of authors, collaboration, and country of the first author. Results: Of 216 (0.19%) articles were published by radiologists in five general medical journals between 1996 and 2010, 83 were original articles. Fifteen (18.1%) original articles were concerned with the field of vascular/interventional radiology, 24 (28.9%) used combined imaging techniques, 76 (91.6%) were clinical research, 63 (75.9%) had a sample size of >50, 65 (78.3%) were prospective, 78 (94.0%) performed statistical analysis, 83 (100%) showed positive study outcomes, 57 (68.7%) were funded, 49 (59.0%) had from four to seven authors, and 79 (95.2%) were collaborative studies. Conclusions: A very small number (0.19%) in five high impact general medical journals was published by radiologists between 1996 and 2010

  18. The application of cost-benefit analysis to the radiological protection of the public

    International Nuclear Information System (INIS)

    1980-03-01

    The subject of this document is the quantification of the potential harm caused to the general public by ionising radiation in normal operating circumstances. The object is to enable the health detriment from a practice involving exposure to ionising radiation to be directly compared with the costs of keeping the ensuing doses as low as reasonably achievable. Chapter headings include: development of radiological protection criteria; principles underlying the valuation of harm from radiation exposure; risk evaluation approach to costing of detriment; monetary valuations; distribution of costs and risk in time. Appendices cover the following: cost benefit analysis (principles); recommendations of ICRP on the use of cost benefit analysis; life valuation studies (review); application of cost benefit analysis to the value of the man sievert. (U.K.)

  19. An analysis of radiological research publications in high impact general medical journals between 1996 and 2010.

    Science.gov (United States)

    Ku, You Jin; Yoon, Dae Young; Yun, Eun Joo; Baek, Sora; Lim, Kyoung Ja; Seo, Young Lan; Choi, Chul Soon; Bae, Sang Hoon

    2013-06-01

    To evaluate scientific papers published by radiologists in high impact general medical journals between 1996 and 2010. A MEDLINE search was performed in five high impact general medical journals (AIM, BMJ, JAMA, Lancet, and NEJM) for all articles of which a radiologist was the first author between 1996 and 2010. The following information was abstracted from the original articles: radiological subspecialty, imaging technique used, type of research, sample size, study design, statistical analysis, study outcome, declared funding, number of authors, collaboration, and country of the first author. Of 216 (0.19%) articles were published by radiologists in five general medical journals between 1996 and 2010, 83 were original articles. Fifteen (18.1%) original articles were concerned with the field of vascular/interventional radiology, 24 (28.9%) used combined imaging techniques, 76 (91.6%) were clinical research, 63 (75.9%) had a sample size of >50, 65 (78.3%) were prospective, 78 (94.0%) performed statistical analysis, 83 (100%) showed positive study outcomes, 57 (68.7%) were funded, 49 (59.0%) had from four to seven authors, and 79 (95.2%) were collaborative studies. A very small number (0.19%) in five high impact general medical journals was published by radiologists between 1996 and 2010. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  20. A model for assessing the radiological impacts of deep sea disposal of radioactive wastes: development of the model and preliminary results

    International Nuclear Information System (INIS)

    Poulin, M.; Chartier, M.; Durrieu de Madron, X.

    1987-10-01

    A new numerical model has been developed in France to assess the radiological consequences of low level radioactive waste disposal on the sea bottom of the Atlantic Ocean. It is a box model covering the world ocean with a finer resolution in the North Atlantic and near the Nuclear Energy Agency dumpsite. The main processes involved in the nuclides transfer from the drums to man are modelled or parameterized: time variations of the nuclides release, advection and diffusion by the ocean fluid, adsorption-desorption on particles, sedimentation and burial of sediments, transfers through organisms living in the sea (fishes, crustaceans, molluscs, seaweeds, plankton,...). The dose equivalent to critical group members and the collective dose equivalent are assessed. A sensitivity analysis of the model has been performed to assess the reliability of the dose calculations. An intercomparison exercise has been achieved with two other independent models on a benchmark problem

  1. Preliminary radiological readings on the old uraniferous mining site of Rophin (Puy-de-Dome); Releves radiologiques preliminaires sur l'ancien site minier uranifere de Rophin (Puy de Dome)

    Energy Technology Data Exchange (ETDEWEB)

    Chareyron, Bruno

    2012-05-02

    After a presentation of the site, of the objectives, limits and methodology of the measurement campaign, this document reports and comments the radiological measurements performed by the CRIIRAD on the old uranium mining site of Rophin and its surroundings (gamma radiation). It comments measurements performed 1 meter above the ground and on soils, and anomalies clearly related to past industrial activities. It comments the results of a radiological analysis performed on released waters (uranium 238, radon 222), and on sediments and soils

  2. Neutronic Analysis and Radiological Safety of RSG-GAS Reactor on 300 Grams Uranium Silicide Core

    International Nuclear Information System (INIS)

    Pande Made Udiyani; Lily Suparlina; Rokhmadi

    2007-01-01

    As starting of usage silicide U 250 g fuel element in the core of RSG-GAS and will be continued with usage of silicide U 300 g fuel element, hence done beforehand neutronic analyse and radiological safety of RSG-GAS. Calculation done by ORIGEN2.1 code to calculate source term, and also by PC-COSYMA code to calculate radiological safety of radioactive dispersion from RSG-GAS. Calculation of radioactive dispersion done at condition of reactor is postulated be happened an accident of LOCA causing one fuel element to melt. Neutronic analysis indicate that silicide U 250 g full core shall to be operated beforehand during 625 MWD before converted to silicide U 300 g core. During operation of transition core with mixture of silicide U 250 g and 300 g, all parameter fulfill criterion of safety Designed Balance core of silicide U 300 g will be reached at the time of fifth full core. Result of calculation indicate that through mixture core of silicide U 250 and 300 g proposed can form silicide U 300 g balance core of reactor RSG-GAS safely. Calculation of radiology safety by deterministic for silicide U 300 g balance core, and accident postulation which is equal to core of silicide U 250 g yield output in the form of radiation activity (radionuclide concentration in the air and deposition on the ground), radiation dose (collective and individual), radiation effect (short- and long-range), which accepted by society in each perceived sector. Result of calculation indicated that dose accepted by society is not pass permitted boundary for public society if happened accident. (author)

  3. Clinical and radiological comparison of tuberculous and pyogenic spondylitis. An analysis of 49 operated cases

    International Nuclear Information System (INIS)

    Dzelzite, S.; Maurins, G.

    1998-01-01

    Objective: To perform retrospective analysis of 49 operated patients with histologically proven spondylodiscitis of tbc and pyogenic origin. Patient histories, laboratory tests and radiographic findings were statistically compared between two groups. We estimated that in 16 cases (32.6%) origin of spondylodiscitis was tbc and 33 cases (67.4%) origin was pyogenic. All cases of tbc spondylitis (except one drug resistant tbc form) were with previously proved tbc diagnosis of different localisation. Radiological findings for the tbc cases were more than two-vertebra involvement and deformation of vertebral column axis. Pyogenic spondylodiscitis (33 cases) were derived from or after - 1. lumbal discectomies (7 cases), 2. operation on retroperitoneal cavity (6 cases) including 3 cases after prothesation of abdominal aorta, 3. closed spine trauma (4 cases), 4. hematogenic dissemination of pyogenic infection from different localisation - kidney, lung, sinuses (8 cases). In 8 cases we did not estimate potential cause of spondylodiscitis. Conclusion: A definite diagnosis of spondylodiscitis was established by means of biopsy, histological evidence and bacterial culture. There are not specific radiological findings to differentiate tbc spondylodiscitis from pyogenic spondylodiscitis. (Full text)

  4. Cost analysis of radiological interventional procedures and reimbursement within a clinic

    International Nuclear Information System (INIS)

    Strotzer, M.; Voelk, M.; Lenhart, M.; Fruend, R.; Feuerbach, S.

    2002-01-01

    Purpose: Analysis of costs for vascular radiological interventions on a per patient basis and comparison with reimbursement based on GOAe(Gebuehrenordnung fuer Aerzte) and DKG-NT (Deutsche Krankenhausgesellschaft-Nebenkostentarif). Material and Methods: The ten procedures most frequently performed within 12 months were evaluated. Personnel costs were derived from precise costs per hour and estimated procedure time for each intervention. Costs for medical devices were included. Reimbursement based on GOAewas calculated using the official conversion factor of 0.114 DM for each specific relative value unit and a multiplication factor of 1.0. The corresponding conversion factor for DKG-NT, determined by the DKG, was 0.168 DM. Results: A total of 832 interventional procedures were included. Marked differences between calculated costs and reimbursement rates were found. Regarding the ten most frequently performed procedures, there was a deficit of 1.06 million DM according GOAedata (factor 1.0) and 0.787 million DM according DKG-NT. The percentage of reimbursement was only 34.2 (GOAe; factor 1.0) and 51.3 (DKG-NT), respectively. Conclusion: Reimbursement of radiological interventional procedures based on GOAeand DKG-NT data is of limited value for economic controlling purposes within a hospital. (orig.) [de

  5. Preliminary Analysis of Remote Monitoring and Robotic Concepts for Performance Confirmation

    International Nuclear Information System (INIS)

    McAffee, D.A.

    1997-01-01

    main Performance Confirmation monitoring needs and requirements during the post-emplacement preclosure period. This includes radiological, non-radiological, host rock, and infrastructure performance monitoring needs. It also includes monitoring for possible off-normal events. (Presented in Section 7.3). (3) Identify general approaches and methods for obtaining performance information from within the emplacement drifts for Performance Confirmation. (Presented in Section 7.4) (4)Review and discuss available technologies and design strategies that may permit the use of remotely operated systems within the hostile thermal and radiation environment expected within the emplacement drifts. (Presented in Section 7.5). (5) Based on Performance Confirmation monitoring needs and available technologies, identify potential application areas for remote systems and robotics for post-emplacement preclosure Performance Confirmation activities (Presented in Section 7.6). (6) Develop preliminary remote monitoring and robotic concepts for post-emplacement, preclosure Performance Confirmation activities. (Presented in Section 7.7) This analysis is being performed very early in the systems engineering cycle, even as issues related to the Performance Confirmation program planning phase are being formulated and while the associated needs, constraints and objectives are yet to be fully determined and defined. This analysis is part of an issue formulation effort and is primarily concerned with identification and description of key issues related to remotely monitoring repository performance for Performance Confirmation. One of the purposes of this analysis is to provide an early investigation of potential design challenges that may have a high impact on future design concepts. This analysis can be used to guide future concept development and help access what is feasible and achievable by application of remote systems technology. Future design and systems engineering analysis with applicable

  6. Analysis of data related to the update of diagnosis reference levels in radiology and nuclear medicine. Assessment 2009-2010

    International Nuclear Information System (INIS)

    Roch, Patrice; Celier, David

    2012-10-01

    This report presents and comments the results of the analysis of 'patient' dosimetric data which radiology and nuclear medicine establishments had to transmit to the IRSN. The first part concerns conventional radiology and the analysis is made from a general point of view, and then by examination type (in the case of adults and of children). A synthesis of results since 2004 is proposed in terms of transmitted data, of data representativeness, of influence of detection technology on the delivered dose, of evolution of diagnosis reference level. With the same approach, the next parts address scanography examinations and nuclear medicine

  7. SisRadiologia: a new software tool for analysis of radiological accidents and incidents in industrial radiography

    International Nuclear Information System (INIS)

    Lima, Camila M. Araujo; Silva, Francisco C.A. da; Araujo, Rilton A.

    2013-01-01

    According to the International Atomic Energy Agency (IAEA), many efforts have been made by Member states, aiming a better control of radioactive sources. Accidents mostly happened in practices named as high radiological risk and classified by IAEA in categories 1 and 2, being highlighted those related to radiotherapy, large irradiators and industrial radiography. Worldwide, more than 40 radiological accidents have been recorded in the industrial radiography. Worldwide, more than 40 radiological accidents have been recorded in the industrial radiography area, involving 37 workers, 110 members of the public and 12 fatalities. Records display 5 severe radiological accidents in industrial radiography activities in Brazil, in which 7 workers and 19 members of the public were involved. Such events led to hands and fingers radiodermatitis, but to no death occurrence. The purpose of this study is to present a computational program that allows the data acquisition and recording in the company, in such a way to ease a further detailed analysis of radiological event, besides providing the learning cornerstones aiming the avoidance of future occurrences. After one year of the 'Industrial SisRadiologia' computational program application - and mostly based upon the workshop about Analysis and Dose Calculation of Radiological Accidents in Industrial Radiography (Workshop sobre Analise e Calculo de dose de acidentes Radiologicos em Radiografia Industrial - IRD 2012), in which several Radiation Protection officers took part - it can be concluded that the computational program is a powerful tool to data acquisition, as well as, to accidents and incidents events recording and surveying in Industrial Radiography. The program proved to be efficient in the report elaboration to the Brazilian Regulatory Authority, and very useful in workers training to fix the lessons learned from radiological events.

  8. Preliminary Analysis of a Submerged Wave Energy Device

    Science.gov (United States)

    Wagner, J. R.; Wagner, J. J.; Hayatdavoodi, M.; Ertekin, R. C.

    2016-02-01

    Preliminary analysis of a submerged wave energy harvesting device is presented. The device is composed of a thin, horizontally submerged plate that is restricted to heave oscillations under the influence of surface waves. The submerged plate is oscillating, and it can be attached to a fixed rotor, or a piston, to harvest the wave energy. A fully submerged wave energy converter is preferred over a surface energy convertor due to its durability and less visual and physical distractions it presents. In this study, the device is subject to nonlinear shallow-water waves. Wave loads on the submerged oscillating plate are obtained via the Level I Green-Naghdi equations. The unsteady motion of the plate is obtained by solving the nonlinear equations of motion. The results are obtained for a range of waves with varying heights and periods. The amplitude and period of plate oscillations are analyzed as functions of the wave parameters and plate width. Particular attention is given to the selection of the site of desired wave field. Initial estimation on the amount of energy extraction from the device, located near shore at a given site, is provided.

  9. Preliminary radiation criteria and nuclear analysis for ETF

    International Nuclear Information System (INIS)

    Engholm, B.A.

    1980-09-01

    Preliminary biological and materials radiation dose criteria for the Engineering Test Facility are described and tabulated. In keeping with the ETF Mission Statement, a key biological dose criterion is a 24-hour shutdown dose rate of 2 mrem/hr on the surface of the outboard bulk shield. Materials dose criteria, which primarily govern the inboard shield design, include 10 9 rads exposure limit to epoxy insulation, 3 x 10 -4 dpa damage to the TF coil copper stabilizer, and a total nuclear heating rate of 5 kW in the inboard TF coils. Nuclear analysis performed during FY 80 was directed primarily at the inboard and outboard bulk shielding, and at radiation streaming in the neutral beam drift ducts. Inboard and outboard shield thicknesses to achieve the biological and materials radiation criteria are 75 cm inboard and 125 cm outboard, the configuration consisting of alternating layers of stainless steel and borated water. The outboard shield also includes a 5 cm layer of lead. NBI duct streaming analyses performed by ORNL and LASL will play a key role in the design of the duct and NBI shielding in FY 81. The NBI aluminum cryopanel nuclear heating rate during the heating cycle is about 1 milliwatt/cm 3 , which is far less than the permissible limit

  10. Preliminary Analysis For Wolsong Par Effects Using ISACC Calculations

    International Nuclear Information System (INIS)

    Song, Yong Mann; Kim, Dong Ha

    2012-01-01

    In the paper, hydrogen control effects using PARs only are analyzed for severe SBO station blackout (SBO) sequences beyond the design basis accidents in WS-1 which are of CANDU6 type reactor. As a computational tool, the latest version of ISAAC4.3 (Integrated Severe Accident Analysis Code for CANDU), which is a fully integrated and lumped severe accident computer code, is used to simulate hydrogen generation and transport inside the reactor building (R/B) before its failure. For the performance of hydrogen removal, the depletion rate equation of K-PAR developed in Korea is applied. In a CANDU reactor, three areas are identified as sources of hydrogen under severe accidents: fuel-coolant interactions in intact channels, suspended fuel or debris interactions in-calandria tank and debris interactions in-calandria vault. The first two origins provide source for the late ('late' terminology is used because it takes more than one day before calandria tank failure) potential hydrogen combustion before calandria tank failure and all the three origins would provide source for the very late potential hydrogen combustion occurring at or after calaria tank failure. If the hydrogen mitigation system fails, the AICC (adiabatic isochoric complete combustion) burning of highly flammable hydrogen may cause Wolsong R/B failure. So hydrogen induced failure possibility is evaluated, using preliminary ISAAC calculations, under several SBO conditions with and without PAR for both late and very late accident periods

  11. Preliminary analysis of accelerated space flight ionizing radiation testing

    Science.gov (United States)

    Wilson, J. W.; Stock, L. V.; Carter, D. J.; Chang, C. K.

    1982-01-01

    A preliminary analysis shows that radiation dose equivalent to 30 years in the geosynchronous environment can be accumulated in a typical composite material exposed to space for 2 years or less onboard a spacecraft orbiting from perigee of 300 km out to the peak of the inner electron belt (approximately 2750 km). Future work to determine spacecraft orbits better tailored to materials accelerated testing is indicated. It is predicted that a range of 10 to the 9th power to 10 to the 10th power rads would be accumulated in 3-6 mil thick epoxy/graphite exposed by a test spacecraft orbiting in the inner electron belt. This dose is equivalent to the accumulated dose that this material would be expected to have after 30 years in a geosynchronous orbit. It is anticipated that material specimens would be brought back to Earth after 2 years in the radiation environment so that space radiation effects on materials could be analyzed by laboratory methods.

  12. Investigation of Sorption and Diffusion Mechanisms, and Preliminary Economic Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bhave, Ramesh R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Jubin, Robert Thomas [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Spencer, Barry B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Nair, Sankar [Georgia Inst. of Technology, Atlanta, GA (United States)

    2017-02-01

    This report describes the synthesis and evaluation of molecular sieve zeolite membranes to separate and concentrate tritiated water (HTO) from dilute HTO-bearing aqueous streams. Several monovalent and divalent cation exchanged silico alumino phosphate (SAPO-34) molecular sieve zeolite membranes were synthesized on disk supports and characterized with gas and vapor permeation measurements. The pervaporation process performance was evaluated for the separation and concentration of tritiated water. Experiments were performed using tritiated water feed solution containing tritium at the high end of the range (1 mCi/mL) anticipated in a nuclear fuel processing system that includes both acid and water streams recycling. The tritium concentration was about 0.1 ppm. The permeate was recovered under vacuum. The HTO/H2O selectivity and separation factor calculated from the measured tritium concentrations ranged from 0.99 to 1.23, and 0.83-0.98, respectively. Although the membrane performance for HTO separation was lower than expected, several encouraging observations including molecular sieving and high vapor permeance are reported. Additionally, several new approaches are proposed, such as tuning the sorption and diffusion properties offered by small pore LTA zeolite materials, and cation exchanged aluminosilicates with high metal loading. It is hypothesized that substantially improved preferential transport of tritium (HTO) resulting in a more concentrated permeate can be achieved. Preliminary economic analysis for the membrane-based process to concentrate tritiated water is also discussed.

  13. Preliminary analysis of public dose from CFETR gaseous tritium release

    Energy Technology Data Exchange (ETDEWEB)

    Nie, Baojie [Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); University of Science and Technology of China, Hefei, Anhui 230027 (China); Ni, Muyi, E-mail: muyi.ni@fds.org.cn [Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Lian, Chao; Jiang, Jieqiong [Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui 230031 (China)

    2015-02-15

    Highlights: • Present the amounts and limit dose of tritium release to the environment for CFETR. • Perform a preliminary simulation of radiation dose for gaseous tritium release. • Key parameters about soil types, wind speed, stability class, effective release height and age were sensitivity analyzed. • Tritium release amount is recalculated consistently with dose limit in Chinese regulation for CFETR. - Abstract: To demonstrate tritium self-sufficiency and other engineering issues, the scientific conception of Chinese Fusion Engineering Test Reactor (CFETR) has been proposed in China parallel with ITER and before DEMO reactor. Tritium environmental safety for CFETR is an important issue and must be evaluated because of the huge amounts of tritium cycling in reactor. In this work, different tritium release scenarios of CFETR and dose limit regulations in China are introduced. And the public dose is preliminarily analyzed under normal and accidental events. Furthermore, after finishing the sensitivity analysis of key input parameters, the public dose is reevaluated based on extreme parameters. Finally, tritium release amount is recalculated consistently with the dose limit in Chinese regulation for CFETR, which would provide a reference for tritium system design of CFETR.

  14. Cost risk analysis of radioactive waste management Preliminary study

    International Nuclear Information System (INIS)

    Forsstroem, J.

    2006-12-01

    This work begins with exposition of the basics of risk analysis. These basics are then applied to the Finnish radioactive waste disposal environment in which the nuclear power companies are responsible for all costs of radioactive waste management including longterm disposal of spent fuel. Nuclear power companies prepare cost estimates of the waste disposal on a yearly basis to support the decision making on accumulation of resources to the nuclear waste disposal fund. These cost estimates are based on the cost level of the ongoing year. A Monte Carlo simulation model of the costs of the waste disposal system was defined and it was used to produce preliminary results of its cost risk characteristics. Input data was synthesised by modifying the original coefficients of cost uncertainty to define a cost range for each cost item. This is a suitable method for demonstrating results obtainable by the model but it is not accurate enough for supporting decision making. Two key areas of further development were identified: the input data preparation and identifying and handling of (i.e. eliminating or merging) interacting cost elements in the simulation model. Further development in both of the mentioned areas can be carried out by co-operating with the power companies as they are the sources of the original data. (orig.)

  15. Radioactive waste management complex low-level waste radiological composite analysis

    Energy Technology Data Exchange (ETDEWEB)

    McCarthy, J.M.; Becker, B.H.; Magnuson, S.O.; Keck, K.N.; Honeycutt, T.K.

    1998-05-01

    The composite analysis estimates the projected cumulative impacts to future members of the public from the disposal of low-level radioactive waste (LLW) at the Idaho National Engineering and Environmental Laboratory (INEEL) Radioactive Waste Management Complex (RWMC) and all other sources of radioactive contamination at the INEEL that could interact with the LLW disposal facility to affect the radiological dose. Based upon the composite analysis evaluation, waste buried in the Subsurface Disposal Area (SDA) at the RWMC is the only source at the INEEL that will significantly interact with the LLW facility. The source term used in the composite analysis consists of all historical SDA subsurface disposals of radionuclides as well as the authorized LLW subsurface disposal inventory and projected LLW subsurface disposal inventory. Exposure scenarios evaluated in the composite analysis include all the all-pathways and groundwater protection scenarios. The projected dose of 58 mrem/yr exceeds the composite analysis guidance dose constraint of 30 mrem/yr; therefore, an options analysis was conducted to determine the feasibility of reducing the projected annual dose. Three options for creating such a reduction were considered: (1) lowering infiltration of precipitation through the waste by providing a better cover, (2) maintaining control over the RWMC and portions of the INEEL indefinitely, and (3) extending the period of institutional control beyond the 100 years assumed in the composite analysis. Of the three options investigated, maintaining control over the RWMC and a small part of the present INEEL appears to be feasible and cost effective.

  16. Radioactive waste management complex low-level waste radiological composite analysis

    International Nuclear Information System (INIS)

    McCarthy, J.M.; Becker, B.H.; Magnuson, S.O.; Keck, K.N.; Honeycutt, T.K.

    1998-05-01

    The composite analysis estimates the projected cumulative impacts to future members of the public from the disposal of low-level radioactive waste (LLW) at the Idaho National Engineering and Environmental Laboratory (INEEL) Radioactive Waste Management Complex (RWMC) and all other sources of radioactive contamination at the INEEL that could interact with the LLW disposal facility to affect the radiological dose. Based upon the composite analysis evaluation, waste buried in the Subsurface Disposal Area (SDA) at the RWMC is the only source at the INEEL that will significantly interact with the LLW facility. The source term used in the composite analysis consists of all historical SDA subsurface disposals of radionuclides as well as the authorized LLW subsurface disposal inventory and projected LLW subsurface disposal inventory. Exposure scenarios evaluated in the composite analysis include all the all-pathways and groundwater protection scenarios. The projected dose of 58 mrem/yr exceeds the composite analysis guidance dose constraint of 30 mrem/yr; therefore, an options analysis was conducted to determine the feasibility of reducing the projected annual dose. Three options for creating such a reduction were considered: (1) lowering infiltration of precipitation through the waste by providing a better cover, (2) maintaining control over the RWMC and portions of the INEEL indefinitely, and (3) extending the period of institutional control beyond the 100 years assumed in the composite analysis. Of the three options investigated, maintaining control over the RWMC and a small part of the present INEEL appears to be feasible and cost effective

  17. GRDC. A Collaborative Framework for Radiological Background and Contextual Data Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Quiter, Brian J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Ramakrishnan, Lavanya [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Bandstra, Mark S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-12-01

    The Radiation Mobile Analysis Platform (RadMAP) is unique in its capability to collect both high quality radiological data from both gamma-ray detectors and fast neutron detectors and a broad array of contextual data that includes positioning and stance data, high-resolution 3D radiological data from weather sensors, LiDAR, and visual and hyperspectral cameras. The datasets obtained from RadMAP are both voluminous and complex and require analyses from highly diverse communities within both the national laboratory and academic communities. Maintaining a high level of transparency will enable analysis products to further enrich the RadMAP dataset. It is in this spirit of open and collaborative data that the RadMAP team proposed to collect, calibrate, and make available online data from the RadMAP system. The Berkeley Data Cloud (BDC) is a cloud-based data management framework that enables web-based data browsing visualization, and connects curated datasets to custom workflows such that analysis products can be managed and disseminated while maintaining user access rights. BDC enables cloud-based analyses of large datasets in a manner that simulates real-time data collection, such that BDC can be used to test algorithm performance on real and source-injected datasets. Using the BDC framework, a subset of the RadMAP datasets have been disseminated via the Gamma Ray Data Cloud (GRDC) that is hosted through the National Energy Research Science Computing (NERSC) Center, enabling data access to over 40 users at 10 institutions.

  18. Analysis of data relative to the update of diagnosis reference levels in radiology and nuclear medicine. Situation 2004-2006

    International Nuclear Information System (INIS)

    2008-01-01

    This report presents the results of the analysis of patients dosimetry data the radiology and nuclear medicine institutions have to transmit yearly to I.R.S.N. in application of the 12. february decree disposal relative to the diagnosis reference levels in radiology and nuclear medicine. The analysed dosimetry data concern the evaluations realised between the date of decree publication, the 16. march 2004 and 31. december 2006. The so considered results have to allow to the Nuclear Safety Authority to define the evolution needs of the regulation. Particularly, the analysis of delivered doses in radiology and the activities given in nuclear medicine lead to propositions on the possible update of reference values of some examination types. (N.C.)

  19. Grid-connected ICES: preliminary feasibility analysis and evaluation. Volume 2. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1977-06-30

    The HEAL Complex in New Orleans will serve as a Demonstration Community for which the ICES Demonstration System will be designed. The complex is a group of hospitals, clinics, research facilities, and medical educational facilities. The five tasks reported on are: preliminary energy analysis; preliminary institutional assessment; conceptual design; firming-up of commitments; and detailed work management plan.

  20. Preliminary safety analysis of molten salt breeder reactor

    International Nuclear Information System (INIS)

    Cheng Maosong; Dai Zhimin

    2013-01-01

    Background: The molten salt reactor is one of the six advanced reactor concepts identified by the Generation IV International Forum as a candidate for cooperative development, which is characterized by remarkable advantages in inherent safety, fuel cycle, miniaturization, effective utilization of nuclear resources and proliferation resistance. ORNL finished the conceptual design of Molten Salt Breeder Reactor (MSBR) based on the design, building and operation of Molten Salt Reactor Experiment (MSRE). Purpose: We attempt to implement the preliminary safety analysis of MSBR in order to provide a reference for the design and optimization of MSBR in the future. Methods: According to the conceptual design of MSBR, a model of safety analysis using point kinetics coupled with the simplified heat transfer mechanism is presented. The model is applied to simulate the transient phenomena of MSBR initiated by an abnormal step reactivity addition and an abnormal ramp reactivity addition at full-power equilibrium condition. Results: The thermal power in the core increases rapidly at the beginning and is accompanied by a rise of the fuel and graphite temperatures after 100, 300, 500 and 600 pcm reactivity addition. The maximum outlet temperature of the fuel in the core is at 1250℃ in 500 pcm reactivity addition, but up to 1350℃ in 600 pcm reactivity addition. The maximum of the power and the temperature are delayed and lower in the ramp reactivity addition rather than in the step reactivity addition. Conclusions: Based on the results, when the reactivity inserted is less than 500 pcm in maximum at full power equilibrium condition, the structural material in Hastelloy-N is not melted and can keep integrity without external control action. And it is necessary to try to avoid inserting a reactivity at short time. (authors)

  1. Conversion Preliminary Safety Analysis Report for the NIST Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Diamond, D. J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Baek, J. S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Hanson, A. L. [Brookhaven National Lab. (BNL), Upton, NY (United States); Cheng, L-Y [Brookhaven National Lab. (BNL), Upton, NY (United States); Brown, N. [Brookhaven National Lab. (BNL), Upton, NY (United States); Cuadra, A. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-01-30

    The NIST Center for Neutron Research (NCNR) is a reactor-laboratory complex providing the National Institute of Standards and Technology (NIST) and the nation with a world-class facility for the performance of neutron-based research. The heart of this facility is the NIST research reactor (aka NBSR); a heavy water moderated and cooled reactor operating at 20 MW. It is fueled with high-enriched uranium (HEU) fuel elements. A Global Threat Reduction Initiative (GTRI) program is underway to convert the reactor to low-enriched uranium (LEU) fuel. This program includes the qualification of the proposed fuel, uranium and molybdenum alloy foil clad in an aluminum alloy, and the development of the fabrication techniques. This report is a preliminary version of the Safety Analysis Report (SAR) that would be submitted to the U.S. Nuclear Regulatory Commission (NRC) for approval prior to conversion. The report follows the recommended format and content from the NRC codified in NUREG-1537, “Guidelines for Preparing and Reviewing Applications for the Licensing of Non-power Reactors,” Chapter 18, “Highly Enriched to Low-Enriched Uranium Conversions.” The emphasis in any conversion SAR is to explain the differences between the LEU and HEU cores and to show the acceptability of the new design; there is no need to repeat information regarding the current reactor that will not change upon conversion. Hence, as seen in the report, the bulk of the SAR is devoted to Chapter 4, Reactor Description, and Chapter 13, Safety Analysis.

  2. Cost benefit analysis of the radiological shielding of medical cyclotrons using a genetic algorithm

    International Nuclear Information System (INIS)

    Mukherjee, Bhaskar

    2001-01-01

    Adequate radiation shielding is vital to the safe operation of modern commercial medical cyclotrons producing large yields of short-lived radioisotopes. The radiological shielding constitutes a significant capital investment for any new cyclotron-based radioisotope production facility; hence, the shielding design requires an accurate cost-benefit analysis often based on a complex multi-variant optimization technique. This paper demonstrates the application of a Genetic Algorithm (GA) for the optimum design of the high yield target cave of a Medical Cyclotron radioisotope production facility based in Sydney, Australia. The GA is a novel optimization technique that mimics the Darwinian Evolution paradigm and is ideally suited to search for global optima in a large multi-dimensional solution space

  3. Radiological accidents: analysis of the information disseminated by media and public acceptance of nuclear technology

    International Nuclear Information System (INIS)

    Delgado, Jose Ubiratan; Tauhata, Luiz; Garcia, Marcia Maria

    1995-01-01

    A methodology to treat quantitatively information by Media concerning a nuclear or a radiological accident is presented. It allows us to classify information according to the amount, importance and way of showing, into one indicator, named Information Equivalent. This establishes a procedure for analysis of released information and includes: number of head-lines, illustrations, printed lines, editorials, authorities quoted and so on. Interpretation becomes easier when the evolution and statistical trend of this indicator is observed. The application to evaluate the dissemination of the accident which took place in 1987 in Goiania, Brazil, was satisfactory and allowed us to purpose a model. This will aid the planning, the decision making process and it will improve relationships between technical staff and media during the emergency. (author). 5 refs., 4 figs., 3 tabs

  4. Indian Point Nuclear Power Station: verification analysis of County Radiological Emergency-Response Plans

    International Nuclear Information System (INIS)

    Nagle, J.; Whitfield, R.

    1983-05-01

    This report was developed as a management tool for use by the Federal Emergency Management Agency (FEMA) Region II staff. The analysis summarized in this report was undertaken to verify the extent to which procedures, training programs, and resources set forth in the County Radiological Emergency Response Plans (CRERPs) for Orange, Putnam, and Westchester counties in New York had been realized prior to the March 9, 1983, exercise of the Indian Point Nuclear Power Station near Buchanan, New York. To this end, a telephone survey of county emergency response organizations was conducted between January 19 and February 22, 1983. This report presents the results of responses obtained from this survey of county emergency response organizations

  5. RASCAL 4.l: evaluation system for the analysis of the radiological consequences

    International Nuclear Information System (INIS)

    Miguel, I. de; Gomez-Arguello, B.

    2012-01-01

    Recently the Spanish Nuclear Safety Council (CSN) has promoted the replacement of the code used in the Spanish Nuclear Power Plants to estimate potential and actual doses due to atmospheric releases. IRDAM Code (interactive Rapid Dose Assessment Model, 1983) by RASCAL Code version 4.1 (Radiological Assessment System for consequence Analysis). This code was developed by the NRC (Nuclear Regulatory Commission) to evaluate releases from nuclear power plants, spent fuel storage pools and casks, fuel cycle facilities and radioactive material handling facilities. RASCAL was officially requested to the Spanish nuclear power plants in February 1st, 2012, and it can be used for external dose assessment and to evaluate the recommended protective action for the public in a specific situation (sheltering, prophylaxis, evacuation, etc.). (Author)

  6. Health effects models for off-site radiological consequence analysis on nuclear reactor accidents (II)

    Energy Technology Data Exchange (ETDEWEB)

    Homma, Toshimitsu [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Takahashi, Tomoyuki [Kyoto Univ., Kumatori, Osaka (Japan). Research Reactor Inst; Yonehara, Hidenori [National Inst. of Radiological Sciences, Chiba (Japan)] [eds.

    2000-12-01

    This report is a revision of JAERI-M 91-005, 'Health Effects Models for Off-Site Radiological Consequence Analysis of Nuclear Reactor Accidents'. This revision provides a review of two revisions of NUREG/CR-4214 reports by the U.S. Nuclear Regulatory Commission which is the basis of the JAERI health effects models and other several recent reports that may impact the health effects models by international organizations. The major changes to the first version of the JAERI health effects models and the recommended parameters in this report are for late somatic effects. These changes reflect recent changes in cancer risk factors that have come from longer followup and revised dosimetry in major studies on the Japanese A-bomb survivors. This report also provides suggestions about future revisions of computational aspects on health effects models. (author)

  7. Health effects models for off-site radiological consequence analysis on nuclear reactor accidents (II)

    International Nuclear Information System (INIS)

    Homma, Toshimitsu

    2000-12-01

    This report is a revision of JAERI-M 91-005, 'Health Effects Models for Off-Site Radiological Consequence Analysis of Nuclear Reactor Accidents'. This revision provides a review of two revisions of NUREG/CR-4214 reports by the U.S. Nuclear Regulatory Commission which is the basis of the JAERI health effects models and other several recent reports that may impact the health effects models by international organizations. The major changes to the first version of the JAERI health effects models and the recommended parameters in this report are for late somatic effects. These changes reflect recent changes in cancer risk factors that have come from longer followup and revised dosimetry in major studies on the Japanese A-bomb survivors. This report also provides suggestions about future revisions of computational aspects on health effects models. (author)

  8. A Preliminary Tsunami vulnerability analysis for Bakirkoy district in Istanbul

    Science.gov (United States)

    Tufekci, Duygu; Lutfi Suzen, M.; Cevdet Yalciner, Ahmet; Zaytsev, Andrey

    2016-04-01

    Resilience of coastal utilities after earthquakes and tsunamis has major importance for efficient and proper rescue and recovery operations soon after the disasters. Vulnerability assessment of coastal areas under extreme events has major importance for preparedness and development of mitigation strategies. The Sea of Marmara has experienced numerous earthquakes as well as associated tsunamis. There are variety of coastal facilities such as ports, small craft harbors, and terminals for maritime transportation, water front roads and business centers mainly at North Coast of Marmara Sea in megacity Istanbul. A detailed vulnerability analysis for Yenikapi region and a detailed resilience analysis for Haydarpasa port in Istanbul have been studied in previously by Cankaya et al., (2015) and Aytore et al., (2015) in SATREPS project. In this study, the methodology of vulnerability analysis under tsunami attack given in Cankaya et al., (2015) is modified and applied to Bakirkoy district of Istanbul. Bakirkoy district is located at western part of Istanbul and faces to the North Coast of Marmara Sea from 28.77oE to 28.89oE. High resolution spatial dataset of Istanbul Metropolitan Municipality (IMM) is used and analyzed. The bathymetry and topography database and the spatial dataset containing all buildings/structures/infrastructures in the district are collated and utilized for tsunami numerical modeling and following vulnerability analysis. The tsunami parameters from deterministically defined worst case scenarios are computed from the simulations using tsunami numerical model NAMI DANCE. The vulnerability assessment parameters in the district according to vulnerability and resilience are defined; and scored by implementation of a GIS based TVA with appropriate MCDA methods. The risk level is computed using tsunami intensity (level of flow depth from simulations) and TVA results at every location in Bakirkoy district. The preliminary results are presented and discussed

  9. The novel application of Benford's second order analysis for monitoring radiation output in interventional radiology.

    Science.gov (United States)

    Cournane, S; Sheehy, N; Cooke, J

    2014-06-01

    Benford's law is an empirical observation which predicts the expected frequency of digits in naturally occurring datasets spanning multiple orders of magnitude, with the law having been most successfully applied as an audit tool in accountancy. This study investigated the sensitivity of the technique in identifying system output changes using simulated changes in interventional radiology Dose-Area-Product (DAP) data, with any deviations from Benford's distribution identified using z-statistics. The radiation output for interventional radiology X-ray equipment is monitored annually during quality control testing; however, for a considerable portion of the year an increased output of the system, potentially caused by engineering adjustments or spontaneous system faults may go unnoticed, leading to a potential increase in the radiation dose to patients. In normal operation recorded examination radiation outputs vary over multiple orders of magnitude rendering the application of normal statistics ineffective for detecting systematic changes in the output. In this work, the annual DAP datasets complied with Benford's first order law for first, second and combinations of the first and second digits. Further, a continuous 'rolling' second order technique was devised for trending simulated changes over shorter timescales. This distribution analysis, the first employment of the method for radiation output trending, detected significant changes simulated on the original data, proving the technique useful in this case. The potential is demonstrated for implementation of this novel analysis for monitoring and identifying change in suitable datasets for the purpose of system process control. Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  10. Analysis of skull asymmetry in different historical periods using radiological examinations

    International Nuclear Information System (INIS)

    Gawlikowska, A.; Czerwinski, F.; Dzieciolowska, E.; Miklaszewska, D.; Adamiec, E.; Szczurowski, J.

    2007-01-01

    Asymmetry is a very common phenomenon in nature. Occurrence of asymmetry and knowledge of correct structure, especially a range of variability which is not a pathology but only an individual variation, are the basis for interpretation of results of radiological examination of the skulls both in research work and in diagnostic examinations, which are widely performed in modern medicine. There are many methods of estimation of the asymmetry. The aim of this study was to estimate the symmetry of skulls from selected historic populations. The studied material consisted of two skull populations - contemporary consisting of 82 skulls and medieval - 77 skulls from Grodek. X-rays in P-A and skull-base projections were performed. The images were scanned and calibrated by means of MicroStation 95 Academic Edition software. Using tools for measurement of vector elements, distances between selected bilateral points of the skull were taken. All data were analyzed statistically. Asymmetry was observed in the skulls of both populations. Some diameters were higher on the left side, some on the right side. High levels of asymmetry index in the superior facial part and in the posterior part of the skull base were observed. The levels of the asymmetry indexes in both groups were similar. Radiological pictures in two projections should be taken for correct analysis of the skull asymmetry. The examination of the asymmetry of the landmarks should be based on the analysis of diameters from two different points of reference. The human skull does not demonstrate a clear domination of one side. The largest variations were observed in the shape and localization of the foramina of the skull . It is associated with the differences of the position of the neurovascular elements which pass through these foramina. (author)

  11. Bibliometric Analysis of Manuscript Characteristics That Influence Citations: A Comparison of Six Major Radiology Journals.

    Science.gov (United States)

    Shekhani, Haris Naseem; Shariff, Shoaib; Bhulani, Nizar; Khosa, Faisal; Hanna, Tarek Noel

    2017-12-01

    The objective of our study was to investigate radiology manuscript characteristics that influence citation rate, capturing features of manuscript construction that are discrete from study design. Consecutive articles published from January 2004 to June 2004 were collected from the six major radiology journals with the highest impact factors: Radiology (impact factor, 5.076), Investigative Radiology (2.320), American Journal of Neuroradiology (AJNR) (2.384), RadioGraphics (2.494), European Radiology (2.364), and American Journal of Roentgenology (2.406). The citation count for these articles was retrieved from the Web of Science, and 29 article characteristics were tabulated manually. A point-biserial correlation, Spearman rank-order correlation, and multiple regression model were performed to predict citation number from the collected variables. A total of 703 articles-211 published in Radiology, 48 in Investigative Radiology, 106 in AJNR, 52 in RadioGraphics, 129 in European Radiology, and 157 in AJR-were evaluated. Punctuation was included in the title in 55% of the articles and had the highest statistically significant positive correlation to citation rate (point-biserial correlation coefficient [r pb ] = 0.85, p radiology. Using bibliometric knowledge, authors can craft a title, abstract, and text that may enhance visibility and citation count over what they would otherwise experience.

  12. Analysis of radiology education in undergraduate medical doctors training in Europe

    International Nuclear Information System (INIS)

    Kourdioukova, Elena V.; Valcke, Martin; Derese, Anselme; Verstraete, Koenraad L.

    2011-01-01

    Objectives: The purpose of the present study is to describe how undergraduate radiology teaching is organized in Europe and to identify important characteristics of undergraduate radiology curriculum. Methods: An electronic survey on undergraduate teaching was distributed by the European Society of Radiology (ESR) to 38 national delegates of the ESR Education Committee. Results: The 'classic type' of radiology teaching method is more frequent than the 'modular type'. In 38% of medical training centres the first experience with radiology is in pre-clinical years. The students enrolled in the fourth medical year experience the largest involvement in radiology education. The total number of teaching hours (mean 89 h, median 76 h) varies across the countries and differs depending on the radiological topic (mean across all topics 14.8 h, median 13). Written tests and oral exams were the most frequently used examination modes. Clerkships are reported as a key part of training. Conclusion: This first international comparative study of undergraduate radiological curriculum in Europe identifies a large number of differences in curriculum content and teaching methods throughout Europe. More research is needed to establish the radiological educational competences resulting from these differing curricula's to improve and to standardize the teaching according to (inter)national and institutional needs.

  13. Analysis of Operation Plumbbob nuclear test: BOLTZMANN radiological and meteorological data

    International Nuclear Information System (INIS)

    Steadman, C.R. Jr.; Kennedy, N.C.; Quinn, V.E.

    1983-09-01

    This report describes the Weather Service Nuclear Support Office (WSNSO) analyses of the radiological and meteorological data collected for the BOLTZMANN nuclear test of Operation PLUMBBOB. Inconsistencies in the radiological data and their resolution are discussed. The methods of converting aerial radiological data to equivalent ground-level values and of estimating fallout arrival times are presented. The meteorological situation on D-day is described. A comparison of the WSNSO fallout analyses with analyses in the late 1950's is presented. The appendices contain tabulated radiological data used in the fallout analyses, and contain discussions of the BOLTZMANN hot spot contention and of the enhanced activity at Portola, California

  14. Experimental Design and Data Analysis in Receiver Operating Characteristic Studies: Lessons Learned from Reports in Radiology from 1997 to 20061

    Science.gov (United States)

    Shiraishi, Junji; Pesce, Lorenzo L.; Metz, Charles E.; Doi, Kunio

    2009-01-01

    Purpose: To provide a broad perspective concerning the recent use of receiver operating characteristic (ROC) analysis in medical imaging by reviewing ROC studies published in Radiology between 1997 and 2006 for experimental design, imaging modality, medical condition, and ROC paradigm. Materials and Methods: Two hundred ninety-five studies were obtained by conducting a literature search with PubMed with two criteria: publication in Radiology between 1997 and 2006 and occurrence of the phrase “receiver operating characteristic.” Studies returned by the query that were not diagnostic imaging procedure performance evaluations were excluded. Characteristics of the remaining studies were tabulated. Results: Two hundred thirty-three (79.0%) of the 295 studies reported findings based on observers' diagnostic judgments or objective measurements. Forty-three (14.6%) did not include human observers, with most of these reporting an evaluation of a computer-aided diagnosis system or functional data obtained with computed tomography (CT) or magnetic resonance (MR) imaging. The remaining 19 (6.4%) studies were classified as reviews or meta-analyses and were excluded from our subsequent analysis. Among the various imaging modalities, MR imaging (46.0%) and CT (25.7%) were investigated most frequently. Approximately 60% (144 of 233) of ROC studies with human observers published in Radiology included three or fewer observers. Conclusion: ROC analysis is widely used in radiologic research, confirming its fundamental role in assessing diagnostic performance. However, the ROC studies reported in Radiology were not always adequate to support clear and clinically relevant conclusions. © RSNA, 2009 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.2533081632/-/DC1 PMID:19864510

  15. Risk Assessment of Healthcare Waste by Preliminary Hazard Analysis Method

    Directory of Open Access Journals (Sweden)

    Pouran Morovati

    2017-09-01

    Full Text Available Introduction and purpose: Improper management of healthcare waste (HCW can pose considerable risks to human health and the environment and cause serious problems in developing countries such as Iran. In this study, we sought to determine the hazards of HCW in the public hospitals affiliated to Abadan School of Medicine using the preliminary hazard analysis (PHA method. Methods: In this descriptive and analytic study, health risk assessment of HCW in government hospitals affiliated to Abadan School of Medicine (4 public hospitals was carried out by using PHA in the summer of  2016. Results: We noted the high risk of sharps and infectious wastes. Considering the dual risk of injury and disease transmission, sharps were classified in the very high-risk group, and pharmaceutical and chemical and radioactive wastes were classified in the medium-risk group. Sharps posed the highest risk, while pharmaceutical and chemical wastes had the lowest risk. Among the various stages of waste management, the waste treatment stage was the most hazardous in all the studied hospitals. Conclusion: To diminish the risks associated with healthcare waste management in the studied hospitals, adequate training of healthcare workers and care providers, provision of suitable personal protective and transportation equipment, and supervision of the environmental health manager of hospitals should be considered by the authorities.  

  16. The Application of Strength of Association Statistics to the Item Analysis of an In-Training Examination in Diagnostic Radiology.

    Science.gov (United States)

    Diamond, James J.; McCormick, Janet

    1986-01-01

    Using item responses from an in-training examination in diagnostic radiology, the application of a strength of association statistic to the general problem of item analysis is illustrated. Criteria for item selection, general issues of reliability, and error of measurement are discussed. (Author/LMO)

  17. Radiological clerkships as a critical curriculum component in radiology education

    International Nuclear Information System (INIS)

    Kourdioukova, Elena V.; Verstraete, Koenraad L.; Valcke, Martin

    2011-01-01

    Objective: The aim of this research was to explore the perceived value of clinical clerkships in the radiology curriculum as well as the impact of radiology clerkship on students' beliefs about the profession of radiology as a whole and as a career. Methods: This study is a sequel to a previous survey in which student perceptions about radiology curriculum components were investigated. The present study focuses on a further analysis of a subsection in this study, based on 14 statements about radiology clerkship and two statements about radiology as a career. Results: Perceived usefulness of the aspects of radiology clerkship as 'radiology examination', 'skills development' and 'diagnosis focus' were awarded the highest scores. The predict value of the subscale 'radiology examination' on the level of performance was very high (adjusted R 2 = 0.19, p < .001). Conclusion: Students expressed highly favorable evaluation of clerkship as a learning environment to learn to order and to interpret imaging studies as well as an unique possibility to attend various radiological examinations and to access to specific radiology software systems, as well as to get a better view on radiology and to improve image interpretation skills. This positive attitude towards clerkship is closely tied to students' beliefs about the profession of radiology as a whole. These aspects of dedicated radiology clerkship are crucial for effective and high-quality education as well as for the choice of radiology as a career.

  18. Cost analysis of small hydroelectric power plants components and preliminary estimation of global cost

    International Nuclear Information System (INIS)

    Basta, C.; Olive, W.J.; Antunes, J.S.

    1990-01-01

    An analysis of cost for each components of Small Hydroelectric Power Plant, taking into account the real costs of these projects is shown. It also presents a global equation which allows a preliminary estimation of cost for each construction. (author)

  19. Analysis of radiological protection and security in the radioactive diagnosis area in a third level hospital

    International Nuclear Information System (INIS)

    Azorin Vega, J.C.; Aazorin Nieto, J.; Rivera Montalvo, T.

    1998-01-01

    Results from the evaluation made to radiological security and protection conditions prevailing in 13 medical diagnosis rooms with X rays at the National Nutrition Institute Zlavador Zubiran (third level hospital), aiming to give adequate protection and radiological security devices to the staff exposed from that hospital and to comply fully with requirements set by the standards

  20. A comparative analysis of radiological and surgical placement of central venous catheters

    International Nuclear Information System (INIS)

    McBride, Kieran D.; Fisher, Ross; Warnock, Neil; Winfield, David A.; Reed, Malcolm W.; Gaines, Peter A.

    1997-01-01

    Purpose. To compare the differences in practice and outcome of all radiologically and surgically placed central venous catheters retrospectively over a 2-year period simultaneously, at a single institution. Methods.A total of 253 Hickman catheters were inserted in 209 patients; 120 were placed radiologically in 102 patients and 133 were placed surgically in 107 patients. The indication was chemotherapy in 76% of radiological and in 47% of surgical cases; the remainder were for total parenteral nutrition and venous access. Results. There were 6 (4.5%) primary surgical failures and a further 17 (13%) surgical cases requiring multiple placement attempts. Pneumothorax occurred once (0.8%) surgically and four times (3.3%) radiologically. There were no radiological primary misplacements but there were five (3.7%) surgical ones. Catheter or central vein thrombosis occurred in four (3.3%) radiological and five (3.7%) surgical cases. The rate of infection per 1000 catheter-days was 1.9 in radiologically placed catheters and 4.0 in surgically placed ones (p<0.001). Average catheter life-span was similar for the two placement methods (100±23 days). Conclusion. Radiological placement is consistently more reliable than surgical placement. There are fewer placement complications and fewer catheter infections overall

  1. 324 Building Baseline Radiological Characterization

    Energy Technology Data Exchange (ETDEWEB)

    R.J. Reeder, J.C. Cooper

    2010-06-24

    This report documents the analysis of radiological data collected as part of the characterization study performed in 1998. The study was performed to create a baseline of the radiological conditions in the 324 Building.

  2. The Organic Food Market and Marketing Initiatives in Europe: a Preliminary Analysis

    DEFF Research Database (Denmark)

    Kristensen, Niels Heine; Nielsen, Thorkild; Bruselius-Jensen, Maria Louisa

    2003-01-01

    Kristensen NH, Nielsen T, Bruselius-Jensen M, Scheperlen-Bøgh P, Beckie M, Foster C, Midmore P, Padel S (2002): The Organic Food Market and Marketing Initiatives in Europe: a Preliminary Analysis. Final Report to the EU Commission......Kristensen NH, Nielsen T, Bruselius-Jensen M, Scheperlen-Bøgh P, Beckie M, Foster C, Midmore P, Padel S (2002): The Organic Food Market and Marketing Initiatives in Europe: a Preliminary Analysis. Final Report to the EU Commission...

  3. Oxygenates in automotive fuels. Consequence analysis - preliminary study

    International Nuclear Information System (INIS)

    Brandberg, Aa.; Saevbark, B.

    1994-01-01

    Oxygenates is used in gasoline due to several reasons. They are added as high-octane components in unleaded gasoline and as agents to reduce the emission of harmful substances. Oxygenates produced from biomass might constitute a coming market for alternative fuels. This preliminary study describes the prerequisites and consequences of such an oxygenate utilization. 39 refs, 9 figs, 5 tabs

  4. Machine Learning and Radiology

    Science.gov (United States)

    Wang, Shijun; Summers, Ronald M.

    2012-01-01

    In this paper, we give a short introduction to machine learning and survey its applications in radiology. We focused on six categories of applications in radiology: medical image segmentation, registration, computer aided detection and diagnosis, brain function or activity analysis and neurological disease diagnosis from fMR images, content-based image retrieval systems for CT or MRI images, and text analysis of radiology reports using natural language processing (NLP) and natural language understanding (NLU). This survey shows that machine learning plays a key role in many radiology applications. Machine learning identifies complex patterns automatically and helps radiologists make intelligent decisions on radiology data such as conventional radiographs, CT, MRI, and PET images and radiology reports. In many applications, the performance of machine learning-based automatic detection and diagnosis systems has shown to be comparable to that of a well-trained and experienced radiologist. Technology development in machine learning and radiology will benefit from each other in the long run. Key contributions and common characteristics of machine learning techniques in radiology are discussed. We also discuss the problem of translating machine learning applications to the radiology clinical setting, including advantages and potential barriers. PMID:22465077

  5. Machine learning and radiology.

    Science.gov (United States)

    Wang, Shijun; Summers, Ronald M

    2012-07-01

    In this paper, we give a short introduction to machine learning and survey its applications in radiology. We focused on six categories of applications in radiology: medical image segmentation, registration, computer aided detection and diagnosis, brain function or activity analysis and neurological disease diagnosis from fMR images, content-based image retrieval systems for CT or MRI images, and text analysis of radiology reports using natural language processing (NLP) and natural language understanding (NLU). This survey shows that machine learning plays a key role in many radiology applications. Machine learning identifies complex patterns automatically and helps radiologists make intelligent decisions on radiology data such as conventional radiographs, CT, MRI, and PET images and radiology reports. In many applications, the performance of machine learning-based automatic detection and diagnosis systems has shown to be comparable to that of a well-trained and experienced radiologist. Technology development in machine learning and radiology will benefit from each other in the long run. Key contributions and common characteristics of machine learning techniques in radiology are discussed. We also discuss the problem of translating machine learning applications to the radiology clinical setting, including advantages and potential barriers. Copyright © 2012. Published by Elsevier B.V.

  6. Inter-observer variability in diagnosing radiological features of aneurysmal subarachnoid hemorrhage; a preliminary single centre study comparing observers from different specialties and levels of training.

    Science.gov (United States)

    Siddiqui, Usman T; Khan, Anjum F; Shamim, Muhammad Shahzad; Hamid, Rana Shoaib; Alam, Muhammad Mehboob; Emaduddin, Muhammad

    2014-01-01

    A noncontrast computed tomography (CT) scan remains the initial radiological investigation of choice for a patient with suspected aneurysmal subarachnoid hemorrhage (aSAH). This initial scan may be used to derive key information about the underlying aneurysm which may aid in further management. The interpretation, however, is subject to the skill and experience of the interpreting individual. The authors here evaluate the interpretation of such CT scans by different individuals at different levels of training, and in two different specialties (Radiology and Neurosurgery). Initial nonontrast CT scan of 35 patients with aSAH was evaluated independently by four different observers. The observers selected for the study included two from Radiology and two from Neurosurgery at different levels of training; a resident currently in mid training and a resident who had recently graduated from training of each specialty. Measured variables included interpreter's suspicion of presence of subarachnoid blood, side of the subarachnoid hemorrhage, location of the aneurysm, the aneurysm's proximity to vessel bifurcation, number of aneurysm(s), contour of aneurysm(s), presence of intraventricular hemorrhage (IVH), intracerebral hemorrhage (ICH), infarction, hydrocephalus and midline shift. To determine the inter-observer variability (IOV), weighted kappa values were calculated. There was moderate agreement on most of the CT scan findings among all observers. Substantial agreement was found amongst all observers for hydrocephalus, IVH, and ICH. Lowest agreement rates were seen in the location of aneurysm being supra or infra tentorial. There were, however, some noteworthy exceptions. There was substantial to almost perfect agreement between the radiology graduate and radiology resident on most CT findings. The lowest agreement was found between the neurosurgery graduate and the radiology graduate. Our study suggests that although agreements were seen in the interpretation of some of

  7. [Management of cytostatic drugs by nurses: analysis of preliminary results].

    Science.gov (United States)

    Bilski, Bartosz

    2004-01-01

    Cytostatic drugs pose a quite specific occupational risk to health care workers. There is a wide range of potential harmful effects, including remote effects, exerted by this group of drugs. In Polish and international regulations, standards of work safety and hygiene concerning these substances are clearly defined. Nevertheless working conditions in Polish health care institutions are now mostly influenced by economic and organizational problems, which may also be reflected in the compliance with the work safety rules. This paper presents a preliminary analysis of subjective assessment of practice with regard to the management of cytostatics reported by nurses, an occupational group mostly exposed to these substances. The study was carried out at hospital departments in the Warmińsko-Mazurskie Voivodship, where exposure of the staff to these drugs was observed. The study covered the whole nursing staff exposed. Completed questionnaires were obtained from 60 nurses, aged +/- 32 years (20-54 years) with job seniority +/- 8 years (2-18), including 58 nurses with secondary education and two university graduates. Undergraduate education did not develop in respondents skills to work with cytostatics. There is a need to increase the involvement of nursing schools, research institutes and teaching hospitals in the improvement of vocational training of nurses working with cytostatic drugs. To this end, all nurses should be covered with the obligatory training how to handle this group of drugs. The respondents reported that they had acquired their knowledge and experience of managing cytostatics in their work and during training organized at workplace. Despite the acquired knowledge and experience the interviewed nurses did not always comply with work safety and hygiene regulations. The problem of exposure to cytostatic drugs in the form of tablets was most frequently neglected. Some of the nurses were additionally exposed to ionizing radiation. Shortage of the nursing

  8. Uncertainty Analysis on the Health Risk Caused by a Radiological Terror

    International Nuclear Information System (INIS)

    Jeong, Hyojoon; Hwang, Wontae; Kim, Eunhan; Han, Moonhee

    2010-01-01

    Atmospheric dispersion modeling and uncertainty analysis were carried out support the decision making in case of radiological emergency events. The risk caused by inhalation is highly dependent on air concentrations for radionuclides, therefore air monitoring and dispersion modeling have to be performed carefully to reduce the uncertainty of the health risk assessment for the public. When an intentional release of radioactive materials occurs in an urban area, air quality for radioactive materials in the environment is of great importance to take action for countermeasures and environmental risk assessments. Atmospheric modeling is part of the decision making tasks and that it is particularly important for emergency managers as they often need to take actions quickly on very inadequate information. In this study, we assume an 137 Cs explosion of 50 TBq using RDDs in the metropolitan area of Soul, South Korea. California Puff Model is used to calculate an atmospheric dispersion and transport for 137 Cs, and environmental risk analysis is performed using the Monte Carlo method

  9. Analysis of data relative to the update of diagnostic reference levels in radiology and nuclear medicine. 2011-2012 review

    International Nuclear Information System (INIS)

    2014-01-01

    Applying the Order of 24 October 2011 on diagnostic reference levels, departments of radiology and nuclear medicine must send a sample of 'patient' dosimetric data to the IRSN each year. The results of the analysis of dosimetric data performed between the 1 January 2011 and the 31 December 2012 presented in this report should enable the authority to define the needs for updating regulations. Professional involvement in DRLs improved globally over the 2011-2012 period but is heterogeneous according to the imaging area considered. The participation of conventional radiology professionals is still low, with less than 30% against over 75% in CT and 85% in nuclear medicine. Data collection in pediatrics, considering all the fields of medical imaging, remains extremely limited. This shows almost no dose assessment for children by imaging departments, and has the effect of not allowing authorities to provide professionals with DRLs representative of pediatric practices. The analysis of radiology doses and nuclear medicine administered activities by IRSN shows an overall decrease of statistical indicators on which DRLs are indexed. These results lead to proposals for updating reference values for a large number of examinations. In addition to the analysis of data collected for examinations currently mentioned in regulatory texts, IRSN recommends to update DRLs in a more general way by changing the strategy for collecting and updating pediatric DRLs, by including interventional radiology - specialty in which the radiation protection presents a major challenge - by introducing a more ambitious indicator than the 75. percentile in conventional radiology and nuclear medicine - the 25. percentile statistical indicator, and by taking into account new technologies inducing additional exposures to the patient as CT-scan associated with the PET. (authors)

  10. Radiological English

    Energy Technology Data Exchange (ETDEWEB)

    Ribes, R. [Hospital Reina Sofia, Cordoba (Spain). Servicio de Radiologia; Ros, P.R. [Harvard Medical School, Boston, MA (United States). Div. of Radiology

    2007-07-01

    The book is an introductory book to radiological English on the basis that there are a lot of radiologists, radiology residents, radiology nurses, radiology students, and radiographers worldwide whose English level is indeterminate because their reading skills are much higher than their fluency. It is intended to help those health care professionals who need English for their work but do not speak English on a day-to-day basis. (orig.)

  11. Radiological English

    International Nuclear Information System (INIS)

    Ribes, R.; Ros, P.R.

    2007-01-01

    The book is an introductory book to radiological English on the basis that there are a lot of radiologists, radiology residents, radiology nurses, radiology students, and radiographers worldwide whose English level is indeterminate because their reading skills are much higher than their fluency. It is intended to help those health care professionals who need English for their work but do not speak English on a day-to-day basis. (orig.)

  12. Preliminary Analysis of Helicopter Options to Support Tunisian Counterterrorism Operations

    Science.gov (United States)

    2016-04-27

    helicopters from Sikorsky to fulfill a number of roles in counterterrorism operations. Rising costs and delays in delivery raised the question of...whether other cost-effective options exist to meet Tunisia’s helicopter requirement. Approach Our team conducted a preliminary assessment of...alternative helicopters for counterterrorism air assault missions. Any decision to acquire an aircraft must consider many factors, including technical

  13. Comparative analysis of chest radiological findings between avian human influenza and SARS

    International Nuclear Information System (INIS)

    Cai Mingjin; Mai Weiwen; Xian Jianxing; Zhang Jiayun; Lin Wenjian; Wei Liping; Chen Jincheng

    2008-01-01

    Objective: To study the chest radiological findings of a mortal avian human influenza case. Methods: One patient in our hospital was proved to be infected avian human influenza in Guangdong province on March 1, 2006. The Clinical appearances and chest radiological findings of this case were retrospectively analyzed and compared with that of 3 mortal SARS cases out of 16 cases in 2003. Results: Large consolidated areas in left lower lobe was showed in pulmonary radiological findings of this patient and soon developed into ARDS (adult respiratory distress syndrome). However, the pulmonary radiological findings had no characteristic. Characteristics of soaring size and number during short term appeared in SARS instead of avian human influenza. Final diagnosis was up to the etiology and serology examination. Conclusion: Bronchial dissemination was not observed in this avian human influenza case. Pay attention to the avian human influenza in spite of no history of contract with sick or dead poultry in large city. (authors)

  14. A survey of ponticulus posticus: Radiological analysis of atlas in an ...

    African Journals Online (AJOL)

    2015-08-06

    Aug 6, 2015 ... Department of Orthodontics, Faculty of Dentistry, Ordu University,. 52100 Ordu ... atlas is a ring‑like structure consisting of two lateral masses connected by a ... Radiology Department at the Erciyes University, Kayseri,. Turkey.

  15. Comparative analysis of dose levels to patients in radiological procedures guided by fluoroscopy

    International Nuclear Information System (INIS)

    Gomez, Pablo Luis; Fernandez, Manuel; Ramos, Julio A.; Delgado, Jose Miguel; Cons, Nestor

    2013-01-01

    This work presents the comparative data of the dose indicators for patient in radiological processes with respect to the values published in the ICRP document. It is analyzed the need for different strategies to communicate to different specialists mechanisms to optimize the radiation beginning with practice by training of second degree level in radiological protection and then, working with them the basics of equipment management to reduce doses without detriment to the welfare purpose

  16. Some issues on radiological consequences analysis in site selection for nuclear power stations

    International Nuclear Information System (INIS)

    Chen Xiaoqiu; Yue Huiguo

    2006-01-01

    The three considerations, Site safety and environmental protection and emergency preparedness, are the focus of attention in the evaluation of the suitability of a site for nuclear power station. This paper summarized the basic regulatory requirements for the siting of nuclear power station, described the existing problems on radiological consequences analyses during the siting stage and discussed the is- sues that need to concern in the reviewing of the radiological consequences analyses in the siting appraisal stage. (authors)

  17. Protective Alternatives of SMR against Extreme Threat Scenario – A Preliminary Risk Analysis

    International Nuclear Information System (INIS)

    Shohet, I.M.; Ornai, D.; Gal, E.; Ronen, Y.; Vidra, M.

    2014-01-01

    The article presents a preliminary risk analysis of the main features in NPP (Nuclear Power Plant) that includes SMR - Small and Modular Reactors, given an extreme threat scenario. A review of the structure and systems of the SMR is followed by systematic definitions and analysis of the threat scenario to which a preliminary risk analysis was carried out. The article outlines the basic events caused by the referred threat scenario, which had led to possible failure mechanisms according to FTA (Fault-Tree-Analysis),critical protective circuits, and todetecting critical topics for the protection and safety of the reactor

  18. Analysis of data relative to the update of diagnostic reference levels in radiology and nuclear medicine. 2013-2015 review

    International Nuclear Information System (INIS)

    2016-11-01

    Applying the Order of 24 October 2011 on diagnostic reference levels, departments of radiology and nuclear medicine must send a sample of 'patient' dosimetric data to the IRSN each year. The results of the analysis of dosimetric data performed between the 1 January 2013 and the 31 December 2015 presented in this report should enable the authority to define the needs for updating regulation. This assessment takes place in a national and international context particularly rich and active since the last years. More than 20 years after the official introduction of the DRL concept by ICRP and the first regulation requirements at a European level, the good and the bad sides of the DRLs systems implemented by several countries, including France, has shown the necessity of complementary actions regarding some specific practices (pediatrics, interventional radiology). On one hand, from a national point of view, the current collection and analysis system is highly efficient for evaluation of practices in France and for DRL update ability. On the other hand, as an optimization implementation tool, regarding the lack of professionals involvement, the current system should not be considered as fully effective in radiology. However, when the professionals carry out DRL data collection and analysis, optimization actions are implemented for nearly all the cases. During the 2013-2015 period, professionals involvement in DRLs globally improved but is heterogeneous according to the imaging area considered. The participation of conventional radiology professionals is still low, with less than 30% against about 80% in CT and more than 85% in nuclear medicine. From a dosimetric point of view, the national analysis shows an overall decrease of statistical indicators in radiology, computed tomography and nuclear medicine on which DRLs are indexed. These results lead to proposals for updating reference values for a large number of examinations. In addition to the analysis of data collected

  19. Fast neutron background characterization with the Radiological Multi-sensor Analysis Platform (RadMAP)

    Energy Technology Data Exchange (ETDEWEB)

    Davis, John R., E-mail: john.davis@usma.edu [Lawrence Berkeley National Laboratory, Berkeley, CA (United States); The United States Military Academy, West Point, NY (United States); Brubaker, Erik [Sandia National Laboratories, Livermore, CA (United States); Vetter, Kai [Lawrence Berkeley National Laboratory, Berkeley, CA (United States)

    2017-06-21

    In an effort to characterize the fast neutron radiation background, 16 EJ-309 liquid scintillator cells were installed in the Radiological Multi-sensor Analysis Platform (RadMAP) to collect data in the San Francisco Bay Area. Each fast neutron event was associated with specific weather metrics (pressure, temperature, absolute humidity) and GPS coordinates. The expected exponential dependence of the fast neutron count rate on atmospheric pressure was demonstrated and event rates were subsequently adjusted given the measured pressure at the time of detection. Pressure adjusted data was also used to investigate the influence of other environmental conditions on the neutron background rate. Using National Oceanic and Atmospheric Administration (NOAA) coastal area lidar data, an algorithm was implemented to approximate sky-view factors (the total fraction of visible sky) for points along RadMAPs route. Three areas analyzed in San Francisco, Downtown Oakland, and Berkeley all demonstrated a suppression in the background rate of over 50% for the range of sky-view factors measured. This effect, which is due to the shielding of cosmic-ray produced neutrons by surrounding buildings, was comparable to the pressure influence which yielded a 32% suppression in the count rate over the range of pressures measured.

  20. Radiological and genetic analysis of a Late Iron Age mummy from the Tuli Block, Botswana

    Directory of Open Access Journals (Sweden)

    Frank J. Rühli

    2016-02-01

    Full Text Available Mummified human remains are valuable sources of information on past populations. Here we report on the radiological and molecular findings of a partially mummified individual found in northern Botswana. This desiccated mummy from the Tuli region is the first to have been reported from this region. The remains were those of an older male adult of African origin. He was interred in a tightly flexed position and wrapped in an animal skin. Computerised tomography (CT scanning revealed that none of the internal organs was preserved. Multiple post-mortem alterations are seen, but apart from some degenerative changes of the lower vertebral column, the axial skeleton has remained intact. The advanced osteophytosis suggests an older age than what was previously estimated. The aDNA analysis confirms Sotho-Tswana and possibly Khoesan genetic relatedness, as could be expected from individuals from that region. These results represent one of the first CT scans of a mummified individual from southern Africa, and also the first successful aDNA extraction from such remains.

  1. A Current Review of the Meniscus Imaging: Proposition of a Useful Tool for Its Radiologic Analysis

    Directory of Open Access Journals (Sweden)

    Nicolas Lefevre

    2016-01-01

    Full Text Available The main objective of this review was to present a synthesis of the current literature in order to provide a useful tool to clinician in radiologic analysis of the meniscus. All anatomical descriptions were clearly illustrated by MRI, arthroscopy, and/or drawings. The value of standard radiography is extremely limited for the assessment of meniscal injuries but may be indicated to obtain a differential diagnosis such as osteoarthritis. Ultrasound is rarely used as a diagnostic tool for meniscal pathologies and its accuracy is operator-dependent. CT arthrography with multiplanar reconstructions can detect meniscus tears that are not visible on MRI. This technique is also useful in case of MRI contraindications, in postoperative assessment of meniscal sutures and the condition of cartilage covering the articular surfaces. MRI is the most accurate and less invasive method for diagnosing meniscal lesions. MRI allows confirming and characterizing the meniscal lesion, the type, the extension, its association with a cyst, the meniscal extrusion, and assessing cartilage and subchondral bone. New 3D-MRI in three dimensions with isotropic resolution allows the creation of multiplanar reformatted images to obtain from an acquisition in one sectional plane reconstructions in other spatial planes. 3D MRI should further improve the diagnosis of meniscal tears.

  2. A Current Review of the Meniscus Imaging: Proposition of a Useful Tool for Its Radiologic Analysis

    Science.gov (United States)

    Lefevre, Nicolas; Naouri, Jean Francois; Herman, Serge; Gerometta, Antoine; Klouche, Shahnaz; Bohu, Yoann

    2016-01-01

    The main objective of this review was to present a synthesis of the current literature in order to provide a useful tool to clinician in radiologic analysis of the meniscus. All anatomical descriptions were clearly illustrated by MRI, arthroscopy, and/or drawings. The value of standard radiography is extremely limited for the assessment of meniscal injuries but may be indicated to obtain a differential diagnosis such as osteoarthritis. Ultrasound is rarely used as a diagnostic tool for meniscal pathologies and its accuracy is operator-dependent. CT arthrography with multiplanar reconstructions can detect meniscus tears that are not visible on MRI. This technique is also useful in case of MRI contraindications, in postoperative assessment of meniscal sutures and the condition of cartilage covering the articular surfaces. MRI is the most accurate and less invasive method for diagnosing meniscal lesions. MRI allows confirming and characterizing the meniscal lesion, the type, the extension, its association with a cyst, the meniscal extrusion, and assessing cartilage and subchondral bone. New 3D-MRI in three dimensions with isotropic resolution allows the creation of multiplanar reformatted images to obtain from an acquisition in one sectional plane reconstructions in other spatial planes. 3D MRI should further improve the diagnosis of meniscal tears. PMID:27057352

  3. Radiology fundamentals

    CERN Document Server

    Singh, Harjit

    2011-01-01

    ""Radiology Fundamentals"" is a concise introduction to the dynamic field of radiology for medical students, non-radiology house staff, physician assistants, nurse practitioners, radiology assistants, and other allied health professionals. The goal of the book is to provide readers with general examples and brief discussions of basic radiographic principles and to serve as a curriculum guide, supplementing a radiology education and providing a solid foundation for further learning. Introductory chapters provide readers with the fundamental scientific concepts underlying the medical use of imag

  4. Preliminary Assessment of ICRP Dose Conversion Factor Recommendations for Accident Analysis Applications

    International Nuclear Information System (INIS)

    Vincent, A.M.

    2002-01-01

    Accident analysis for U.S. Department of Energy (DOE) nuclear facilities is an integral part of the overall safety basis developed by the contractor to demonstrate facility operation can be conducted safely. An appropriate documented safety analysis for a facility discusses accident phenomenology, quantifies source terms arising from postulated process upset conditions, and applies a standardized, internationally-recognized database of dose conversion factors (DCFs) to evaluate radiological conditions to offsite receptors

  5. Quality assurance program on the individual monitory service of the Protection Radiology Laboratory of the Universidade Federal de Pernambuco, Recife, PE (Brazil): preliminary results

    International Nuclear Information System (INIS)

    Antonino, Paulo H.D.; Filho, Joao A.; Silveira, Sueldo V.

    1996-01-01

    The current stage of the quality assurance program on the individual monitoring service of the Protection Radiology Laboratory of the Universidade Federal de Pernambuco, Recife, PE (Brazil) is presented. The program emphasizes the personnel training and its development is focused to meet national and international standards requirements

  6. Clinical and radiological studies upon a combined method for guided bone regeneration in experimental mandibular defects in dogs - a preliminary communication

    International Nuclear Information System (INIS)

    Borissov, I.; Uzunov, N.; Paskalev, M.

    2004-01-01

    The treated bone defects were compared clinically and radiologically. After a 3-month period of survey, the best results were obtained in the group treated with partially demineralized bone matrix, enzymatically processed and lyophilized dura mater and mucoperiosteal flap. The placement of titanium screw dental implants did not impair the guided bone regeneration, that was confirmed by their good osteointegration

  7. Bibliometric Analysis of Manuscript Title Characteristics Associated With Higher Citation Numbers: A Comparison of Three Major Radiology Journals, AJNR, AJR, and Radiology.

    Science.gov (United States)

    Chokshi, Falgun H; Kang, Jian; Kundu, Suprateek; Castillo, Mauricio

    Our purpose was to determine if associations exist between titles characteristics and citation numbers in Radiology, American Journal of Roentgenology (AJR), and American Journal of Neuroradiology (AJNR). This retrospective study is Institutional Review Board exempt. We searched Web of Science for all original research and review articles in Radiology, AJR, and AJNR between 2006 and 2012 and tabulated number of words in the title, presence of a colon symbol, and presence of an acronym. We used a Poisson regression model to evaluate the association between number of citations and title characteristics. We then used the Wald test to detect pairwise differences in the effect of title characteristics on number of citations among the 3 journals. Between 2006 and 2012, Radiology published 2662, AJR 3998, and AJNR 2581 original research and review articles. There was a citation number increase per title word increase of 1.6% for AJNR and 2.6% for AJR and decrease of 0.8% for Radiology. For all, P citation increases for AJNR (16%), Radiology (14%), and AJR (7.4%). Title acronym was associated with citation increases for AJNR (10%), Radiology (14%), and AJR (13.3%). All P citation numbers in Radiology, AJR, and AJNR. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. The top 100 articles in the radiology of trauma: a bibliometric analysis.

    Science.gov (United States)

    Dolan, Ryan Scott; Hanna, Tarek N; Warraich, Gohar Javed; Johnson, Jamlik-Omari; Khosa, Faisal

    2015-12-01

    The purpose of this study was to identify the 100 top-cited articles in the radiology of trauma, analyze the resulting database to understand factors resulting in highly cited works, and establish trends in trauma imaging. An initial database was created via a Web of Science (WOS) search of all scientific journals using the search terms "trauma" and either "radiology" or a diagnostic modality. Articles were ranked by citation count and screened by two attending radiologists plus a tiebreaker for appropriateness. The following information was collected from each article: WOS all database citations, year, journal, authors, department affiliation, study type and design, sample size, imaging modality, subspecialty, organ, and topic. Citations for the top 100 articles ranged from 82-252, and citations per year ranged from 2.6-37.2. A plurality of articles were published in the 1990s (n = 45) and 1980s (n = 31). Articles were published across 24 journals, most commonly Radiology (n = 31) and Journal of Trauma-Injury, Infection, and Critical Care (n = 28). Articles had an average of five authors and 35 % of first authors were affiliated with a department other than radiology. Forty-six articles had sample sizes of 100 or fewer. Computed tomography (CT) was the most common modality (n = 67), followed by magnetic resonance (MR; n = 22), and X-ray (XR; n = 11). Neuroradiology (n = 48) and abdominal radiology (n = 36) were the most common subspecialties. The 100 top-cited articles in the radiology of trauma are diverse. Subspecialty bibliometric analyses identify the most influential articles of a particular field, providing more implications to clinical radiologists, trainees, researchers, editors, and reviewers than radiology-wide lists.

  9. Failure analysis for ultrasound machines in a radiology department after implementation of predictive maintenance method

    Directory of Open Access Journals (Sweden)

    Greg Chu

    2018-01-01

    Full Text Available Objective: The objective of the study was to perform quantitative failure and fault analysis to the diagnostic ultrasound (US scanners in a radiology department after the implementation of the predictive maintenance (PdM method; to study the reduction trend of machine failure; to understand machine operating parameters affecting the failure; to further optimize the method to maximize the machine clinically service time. Materials and Methods: The PdM method has been implemented to the 5 US machines since 2013. Log books were used to record machine failures and their root causes together with the time spent on repair, all of which were retrieved, categorized, and analyzed for the period between 2013 and 2016. Results: There were a total of 108 cases of failure occurred in these 5 US machines during the 4-year study period. The average number of failure per month for all these machines was 2.4. Failure analysis showed that there were 33 cases (30.5% due to software, 44 cases (40.7% due to hardware, and 31 cases (28.7% due to US probe. There was a statistically significant negative correlation between the time spent on regular quality assurance (QA by hospital physicists with the time spent on faulty parts replacement over the study period (P = 0.007. However, there was no statistically significant correlation between regular QA time and total yearly breakdown case (P = 0.12, although there has been a decreasing trend observed in the yearly total breakdown. Conclusion: There has been a significant improvement on the machine failure of US machines attributed to the concerted effort of sonographers and physicists in our department to practice the PdM method, in that system component repair time has been reduced, and a decreasing trend in the number of system breakdown has been observed.

  10. Correlation of quantitative histopathological morphology and quantitative radiological analysis during aseptic loosening of hip endoprostheses.

    Science.gov (United States)

    Bertz, S; Kriegsmann, J; Eckardt, A; Delank, K-S; Drees, P; Hansen, T; Otto, M

    2006-01-01

    Aseptic hip prosthesis loosening is the most important long-term complication in total hip arthroplasty. Polyethylene (PE) wear is the dominant etiologic factor in aseptic loosening, which together with other factors induces mechanisms resulting in bone loss, and finally in implant loosening. The single-shot radiograph analysis (EBRA, abbreviation for the German term "Einzel-Bild-Röntgenanalyse") is a computerized method for early radiological prediction of aseptic loosening. In this study, EBRA parameters were correlated with histomorphological parameters of the periprosthetic membrane. Periprosthetic membranes obtained from 19 patients during revision surgery of loosened ABG I-type total hip pros-theses were analyzed histologically and morphometrically. The pre-existing EBRA parameters, the thickness of the PE debris lay-er and the dimension of inclination and anteversion, were compared with the density of macrophages and giant cells. Addi-tionally, the semiquantitatively determined density of lymphocytes, plasma cells, giant cells and the size of the necrotic areas were correlated with the EBRA results. All periprosthetic membranes were classified as debris-induced type membranes. We found a positive correlation between the number of giant cells and the thickness of the PE debris layer. There was no significant correlation between the number of macrophages or all semiquantitative parameters and EBRA parameters. The number of giant cells decreased with implant duration. The morphometrically measured number of foreign body giant cells more closely reflects the results of the EBRA. The semiquantitative estimation of giant cell density could not substitute for the morphometrical analysis. The density of macrophages, lymphocytes, plasma cells and the size of necrotic areas did not correlate with the EBRA parameters, indicating that there is no correlation with aseptic loosening.

  11. Radiology illustrated. Pediatric radiology

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In-One (ed.) [Seoul National Univ. College of Medicine (Korea, Republic of). Dept. of Radiology

    2014-11-01

    Depicts characteristic imaging findings of common and uncommon diseases in the pediatric age group. Will serve as an ideal diagnostic reference in daily practice. Offers an excellent teaching aid, with numerous high-quality illustrations. This case-based atlas presents images depicting the findings typically observed when imaging a variety of common and uncommon diseases in the pediatric age group. The cases are organized according to anatomic region, covering disorders of the brain, spinal cord, head and neck, chest, cardiovascular system, gastrointestinal system, genitourinary system, and musculoskeletal system. Cases are presented in a form resembling teaching files, and the images are accompanied by concise informative text. The goal is to provide a diagnostic reference suitable for use in daily routine by both practicing radiologists and radiology residents or fellows. The atlas will also serve as a teaching aide and a study resource, and will offer pediatricians and surgeons guidance on the clinical applications of pediatric imaging.

  12. Preliminary Hazard Analysis applied to Uranium Hexafluoride - UF6 production plant

    International Nuclear Information System (INIS)

    Tomzhinsky, David; Bichmacher, Ricardo; Braganca Junior, Alvaro; Peixoto, Orpet Jose

    1996-01-01

    The purpose of this paper is to present the results of the Preliminary hazard Analysis applied to the UF 6 Production Process, which is part of the UF 6 Conversion Plant. The Conversion Plant has designed to produce a high purified UF 6 in accordance with the nuclear grade standards. This Preliminary Hazard Analysis is the first step in the Risk Management Studies, which are under current development. The analysis evaluated the impact originated from the production process in the plant operators, members of public, equipment, systems and installations as well as the environment. (author)

  13. Radiological dose assessment related to management of naturally occurring radioactive materials generated by the petroleum industry

    International Nuclear Information System (INIS)

    Smith, K.P.; Blunt, D.L.; Williams, G.P.; Tebes, C.L.

    1995-01-01

    A preliminary radiological dose assessment related to equipment decontamination, subsurface disposal, landspreading, equipment smelting, and equipment burial was conducted to address concerns regarding the presence of naturally occurring radioactive materials in production waste streams. The assessment evaluated the relative dose of these activities and included a sensitivity analysis of certain input parameters. Future studies and potential policy actions are recommended

  14. Preliminary analysis of the transient overpower accident for CRBRP. Final report

    International Nuclear Information System (INIS)

    Kastenberg, W.E.; Frank, M.V.

    1975-07-01

    A preliminary analysis of the transient overpower accident for the Clinch River Breeder Reactor Plant (CRBRP) is presented. Several uncertainties in the analysis and the estimation of ramp rates during the transition to disassembly are discussed. The major conclusions are summarized

  15. SUMS preliminary design and data analysis development. [shuttle upper atmosphere mass spectrometer experiment

    Science.gov (United States)

    Hinson, E. W.

    1981-01-01

    The preliminary analysis and data analysis system development for the shuttle upper atmosphere mass spectrometer (SUMS) experiment are discussed. The SUMS experiment is designed to provide free stream atmospheric density, pressure, temperature, and mean molecular weight for the high altitude, high Mach number region.

  16. Analysis of Patients' X-ray Exposure in 146 Percutaneous Radiologic Gastrostomies.

    Science.gov (United States)

    Petersen, Tim-Ole; Reinhardt, Martin; Fuchs, Jochen; Gosch, Dieter; Surov, Alexey; Stumpp, Patrick; Kahn, Thomas; Moche, Michael

    2017-09-01

    Purpose  Analysis of patient´s X-ray exposure during percutaneous radiologic gastrostomies (PRG) in a larger population. Materials and Methods  Data of primary successful PRG-procedures, performed between 2004 and 2015 in 146 patients, were analyzed regarding the exposition to X-ray. Dose-area-product (DAP), dose-length-product (DLP) respectively, and fluoroscopy time (FT) were correlated with the used x-ray systems (Flatpanel Detector (FD) vs. Image Itensifier (BV)) and the necessity for periprocedural placement of a nasogastric tube. Additionally, the effective X-ray dose for PRG placement using fluoroscopy (DL), computed tomography (CT), and cone beam CT (CBCT) was estimated using a conversion factor. Results  The median DFP of PRG-placements under fluoroscopy was 163 cGy*cm 2 (flat panel detector systems: 155 cGy*cm 2 ; X-ray image intensifier: 175 cGy*cm 2 ). The median DLZ was 2.2 min. Intraprocedural placement of a naso- or orogastric probe (n = 68) resulted in a significant prolongation of the median DLZ to 2.5 min versus 2 min in patients with an already existing probe. In addition, dose values were analyzed in smaller samples of patients in which the PRG was placed under CBCT (n = 7, median DFP = 2635 cGy*cm 2 ), or using CT (n = 4, median DLP = 657 mGy*cm). Estimates of the median DFP and DLP showed effective doses of 0.3 mSv for DL-assisted placements (flat panel detector 0.3 mSv, X-ray image converter 0.4 mSv), 7.9 mSv using a CBCT - flat detector, and 9.9 mSv using CT. This corresponds to a factor 26 of DL versus CBCT, or a factor 33 of DL versus CT. Conclusion  In order to minimize X-ray exposure during PRG-procedures for patients and staff, fluoroscopically-guided interventions should employ flat detector systems with short transmittance sequences in low dose mode and with slow image frequency. Series recordings can be dispensed with. The intraprocedural placement of a naso- or orogastric probe

  17. Preliminary study on the radiological and physicochemical quality of the Umgeni Water catchments and drinking water sources in KwaZulu-Natal, South Africa.

    Science.gov (United States)

    Manickum, T; John, W; Terry, S; Hodgson, K

    2014-11-01

    Raw and potable water sample sources, from the Umgeni Water catchment areas (rivers, dams, boreholes) in central KwaZulu-Natal (South Africa), were screened for Uranium concentration and alpha and beta radioactivity. Test methods used were gas flow proportional counting for alpha-beta radioactivity, and kinetic phosphorescence analysis (KPA), for Uranium. The uranium levels (median = 0.525 μg/L, range = water quality (≤15 μg/L). The corresponding alpha and beta radioactivity was ≤0.5 Bq/L (median = 0.084, Interquartile Range (IR) = 0.038, range = 0.018-0.094), and ≤1.0 Bq/L (median = 0.114, IR = 0.096, range = 0.024-0.734), respectively, in compliance with the international WHO limits. For uranium radionuclide, the average dose level, at uranium level of ±0.525 μg/L, was 0.06 μSv/a, which complies with the WHO reference dose level for drinking water (water quality classification, with respect to WHO, is "Blue" - ideal; additional physicochemical analyses indicated good water quality. The analytical test methods employed were found to be suitable for preliminary screening for potential radioactive "hot spots". The observed Uranium levels, and the alpha/beta radioactivity, indicate contribution largely from Naturally Occurring Radioactive Material (NORM), with no significant health risk to humans, or to the environment. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Radiological functional analysis of the vascular system contrast media, methods, results

    CERN Document Server

    1983-01-01

    Scientists and engineers have been involved in medical radiology from the very beginning. At times advances in this field occur at a tremen­ dously fast pace. Developments in radiological diagnostics have - technologically and medically speaking - focused on morphology. At present, computer-aided tomography (CAT) is at a high point in deve1opment, medical application, and validation. The preconditions for this success were rapid advances in electronics and computer technology - in hardware and in software - and an unexpected cost reduction in these fields; the co operation of various scientific disci­ plines was also essential. Functional radiological diagnosis has been neglected in part, owing to the emphasis on morphology, but alone the synthesis of morphology and function prornises further advances. Apart from the limited capabilities ofuItrasonic techniques there is no way other than using X-rays to carry out functional studies of organs and their systems through an intact body surface. It is frequently...

  19. Radiologically assisted percutaneous gastrostomy or enterostomy. A retrospective analysis of 90 procedures

    International Nuclear Information System (INIS)

    Mildenberger, P.; Oberholzer, K.; Kauczor, H.U.; Dueber, C.; Kurz, S.; Schild, H.; Thelen, M.

    1996-01-01

    To analyse retrospectively the indications, technique and results of radiologically induced gastrostomies or enterostomies. Radiologically assisted gastrostomies or enterostomies were induced in 90 patients, mostly with high grade obstructions due to head and neck tumours or oesophageal tumours. 19/90 patients had had previous resection of the oesophagus or gastric operations. A catheter was successfully introduced in all patients. In 11/90 patients this was followed by a two-stage procedure. In 16/90 patients puncture was performed under CT control because of some anatomical peculiarity. Serious complication occurred in 9/90 patients but in only one was surgery necessary. There were no deaths resulting from the procedure but mortality after 30 days was 6.7%. Radiologically assisted gastrostomies or enterostomies are a reliable and effective form of treatment even amongst difficult patients. The results and complications are comparable to those from endoscopic procedures. (orig.) [de

  20. Analysis of Low Appropriateness Score Exam Trends in Decision Support-based Radiology Order Entry System.

    Science.gov (United States)

    Gupta, Supriya; Klein, Kandace; Singh, Anand H; Thrall, James H

    2017-05-01

    Awareness of imaging utilization increased after implementation of Radiology Order Entry with decision support systems (ROE-DS). Our hypothesis is few exams with low Clinical Appropriateness Score (CAS) on ROE-DS are performed. Clinical indications of exams with CAS less than 3 (9-point scale) were re-reviewed and reports analyzed. Structured Query Language-based query retrieved exams with CAS less than 3 in ROE-DS from January 2007 to December 2011. Reasons provided by physicians for ordering these exams and reports of exams performed were analyzed. For each indication, number of exams ordered and performed was calculated. Statistical significance was assessed using Student's t test and χ 2 analysis (P < .05). From 445,984 exams, 12,615 exams (2.8%) had CAS less than 3, and 7,956 exams (63%) were performed. Reasons for ordering of 12,615 low CAS exams were as follows: Requests by physician specialists without further explanation (4,516 = 35.8%), notation of special clinical circumstances (2,877 = 22.8%), requests by nonphysician staff without further explanation (1,383 = 10.9%), absence of suspected finding on previous modality (1,099 = 8.7%), patient preference (737 = 5.8%), and requests based on radiologists' recommendations (706 = 5.6%). Difference between male and female (male < female) preferences for low CAS exams was statistically significant (P < .01). Imaging outcome was highest for extremity MRI cases (66.7%; P < .01). Less than 3% of exams ordered had low CAS and about two-thirds of these were performed. Most common indication for ordering these exams was physician specialist request based on opinion of medical necessity without specification. Extremity MRI constituted the highest positive findings for low CAS exams performed. Published by Elsevier Inc.

  1. Enhanced probabilistic decision analysis for radiological confinement barriers of the International Thermonuclear Experimental Reactor

    International Nuclear Information System (INIS)

    Golinescu, R.P.; Kazimi, M.S.

    1998-01-01

    To ensure a defence-in-depth approach, several radiological confinement barriers surrounding a tokamak plant can be employed. A methodology using probabilistic risk assessment (PRA) techniques is a useful tool for evaluating the performance of each confinement barrier within the context of a limited allowable risk of accidental radioactivity releases. Such a methodology was developed and applied to the confinement strategy for the International Thermonuclear Experimental Reactor (ITER). Accident sequence models were constructed for each of the confinement barriers to evaluate the probabilities of events leading to radioactive releases from the corresponding confinement barrier. The current ITER design requirements set radioactive release and dose limits for individual event sequences grouped in categories by frequency. To limit the plant's overall risk and account for event uncertainties in both frequency and consequence, an analytical form for a limit line is derived here as a complementary cumulative frequency (CCF) of radioactive releases to the environment. By comparing the releases from each confinement barrier against the limit line, a decision can be made about the number of barriers required to comply with the design requirements. The first barrier is the vacuum vessel (VV) and the primary heat transfer systems. The second confinement barrier consists of the cryostat vessel (CV) and the heat transfer system vaults. In case the outer building is needed to act as a third barrier for ITER, a decision model using the multi-attribute utility theory was constructed to help the designer choose the best type of tokamak building. The decision model allows for performing sensitivity analysis on relevant parameters and for design features of new options for the ITER tokamak building. (orig.)

  2. Mission Analysis for Using Preventive Radiological/Nuclear Detection Equipment for Consequence Management

    Energy Technology Data Exchange (ETDEWEB)

    Buddemeier, Brooke R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wood-Zika, Annmarie R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Haynes, Daniel [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Klemic, Gladys A. [US Dept. of Homeland Security National Urban Security Technology Lab., Manhattan, NY (United States); Musolino, Stephen V. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2017-09-01

    The overall objective of this project is to research, evaluate, and test first responder preventive radiological/nuclear detection (PRND) equipment to provide state and local agencies with scientific guidance on how to effectively use this equipment for response after a radiological/nuclear release or detonation. While the equipment being tested in this effort has been specifically designed by technology manufacturers and purchased by responders for preventive detection and source interdiction operations, the fleet of PRND equipment can help fill critical needs for radiological instrumentation should a consequence management (CM) response take place, as it is currently the most widely available and fielded radiological instrumentation by state and local agencies. This effort will provide scientific guidance on the most effective way to utilize this class of equipment for consequence management missions. Gaining a better understanding of how PRND equipment can operate and perform for these missions will allow for recommendations on the tactical approach responders can use for consequence management operations. PRND equipment has been placed into service by federal, state, and local agencies throughout the nation. If the equipment capability and limitations are taken into account, this large inventory can be leveraged to support the emergency response in the aftermath of a radiological or nuclear event. With several hundred makes and models of PRND equipment, often with significantly different detection capabilities that do not align with their nominal PRND equipment type, development of a streamlined categorization scheme with respect to consequence management missions was the first step to identifying safe and effective uses of PRND equipment for radiological/nuclear incident response.

  3. Digital radiology

    International Nuclear Information System (INIS)

    Dallas, W.J.

    1990-01-01

    Radiology is vital to the life-saving efforts of surgeons and other physicians, but precious time can be lost generating the images and transferring them to and from the operating room. Furthermore, hospitals are straining under the task of storing and managing the deluge of diagnostic films produced every year. A 300-bed hospital generates about 1 gigabyte (8 x 10 9 bits) of picture information every day and is legally bound to hold it for three to seven years--30 years in the case of silicosis or black lung disease, illnesses that may have relevance to future lawsuits. Consequently, hospital warehouses are filling with x-ray film and written reports that are important for analysis of patient histories, for comparison between patients, and for analyzing the progress of disease. Yet only a fraction of the information's potential is being used because access is so complicated. What is more, films are easily lost, erasing valuable medical histories

  4. Endobronchial valves in severe emphysematous patients: CT evaluation of lung fissures completeness, treatment radiological response and quantitative emphysema analysis

    Energy Technology Data Exchange (ETDEWEB)

    Koenigkam-Santos, Marcel, E-mail: marcelk46@yahoo.com.br, E-mail: marcelk46@usp.b [Universidade de Sao Paulo (HCFMRP/USP), Ribeirao Preto, SP (Brazil). Hospital das Clinicas da Faculdade de Medicina; Paula, Wagner Diniz de [University of Brasilia (UnB), DF (Brazil). Brasilia University Hospital; Gompelmann, Daniela [University of Heidelberg (Germany). Department of Pneumology and Respiratory Medicine of the Chest Clinic (Thoraxklinik); Kauczor, Hans-Ulrich [University of Heidelberg (Germany). Department of Diagnostic and Interventional Radiology; Heussel, Claus Peter; Puderbach, Michael [University of Heidelberg (Germany). Department of Diagnostic and Interventional Radiology with Nuclear Medicine of the Chest Clinic (Thoraxklinik)

    2013-01-15

    Objective: To evaluate lung fissures completeness, post-treatment radiological response and quantitative CT analysis (QCTA) in a population of severe emphysematous patients submitted to endobronchial valves (EBV) implantation. Materials and Methods: Multi-detectors CT exams of 29 patients were studied, using thin-section low dose protocol without contrast. Two radiologists retrospectively reviewed all images in consensus; fissures completeness was estimated in 5% increments and post-EBV radiological response (target lobe atelectasis/volume loss) was evaluated. QCTA was performed in pre and post-treatment scans using a fully automated software. Results: CT response was present in 16/29 patients. In the negative CT response group, all 13 patients presented incomplete fissures, and mean oblique fissures completeness was 72.8%, against 88.3% in the other group. QCTA most significant results showed a reduced post-treatment total lung volume (LV) (mean 542 ml), reduced EBV-submitted LV (700 ml) and reduced emphysema volume (331.4 ml) in the positive response group, which also showed improved functional tests. Conclusion: EBV benefit is most likely in patients who have complete interlobar fissures and develop lobar atelectasis. In patients with no radiological response we observed a higher prevalence of incomplete fissures and a greater degree of incompleteness. The fully automated QCTA detected the post-treatment alterations, especially in the treated lung analysis. (author)

  5. Analysis of heavy radiological accidents in NPP and gamma-irradiators

    International Nuclear Information System (INIS)

    Angelov, V.; Semova, T.; Bonchev, Ts.

    1995-01-01

    A review of several heavy radiological accidents, their cause, character, radioactivity emission, victims and economical impact is presented in the form of uniform tables. Eleven cases of incidents in power plants and 4 cases of accidents involving powerful gamma irradiators are considered. Radiological accidents in Bulgaria, not connected with the Kozloduy NPP, are listed. The human factor has been identified as the main cause for most of the accidents. It is stressed that the probability of heavy accident increases at the time of reactor refuelling, repair or testing. Technical failures could be eliminated by improved check and diagnostics procedures. 2 tabs., 12 refs

  6. Analysis of heavy radiological accidents in NPP and gamma-irradiators

    Energy Technology Data Exchange (ETDEWEB)

    Angelov, V [Civil Defence Administration, Sofia (Bulgaria); Semova, T; Bonchev, Ts [Sofia Univ. (Bulgaria). Fizicheski Fakultet

    1996-12-31

    A review of several heavy radiological accidents, their cause, character, radioactivity emission, victims and economical impact is presented in the form of uniform tables. Eleven cases of incidents in power plants and 4 cases of accidents involving powerful gamma irradiators are considered. Radiological accidents in Bulgaria, not connected with the Kozloduy NPP, are listed. The human factor has been identified as the main cause for most of the accidents. It is stressed that the probability of heavy accident increases at the time of reactor refuelling, repair or testing. Technical failures could be eliminated by improved check and diagnostics procedures. 2 tabs., 12 refs.

  7. Preliminary worst-case accident analysis to support the conceptual design of a potential repository in tuff

    International Nuclear Information System (INIS)

    Jackson, J.L.; Gram, H.F.; Hong, K.J.; Ng, H.S.; Pendergrass, A.M.

    1984-01-01

    The Nevada Waste Storage Investigations (NNWSI) Project is conducting investigations to determine suitability of a site at Yucca Mountain for development as a high-level waste repository. In support of conceptual design, a preliminary analysis has been performed to identify events that could cause radiological releases from the surface facilities during the operations period. Accidental releases were modeled short-duration release plumes, dispersed under averaged climatic conditions, using the AIRDOS-EPA code. consequences of these accidents, in 50-yr integrated dose commitments to operations personnel, to the minimally exposed member of the public, and to the general population in the surrounding area were calculated. risk to the general public from each event was also assessed. All postulated accidents result in doses to pers of the public that are lower than the 0.5 rem/accident limit set by the NRC in 10 CFR 60. For those accidents that do not involve both fire and breach of waste canisters, doses to operations personnel are behind the NRC limit for routine operations of 5 rem/yr set in 10 CFR 20. Accidents that involve fire and breach of waste canisters may cause doses to some operations personnel that are in excess of this limit

  8. Preliminary worst-case accident analysis to support the conceptual design of a potential repository in tuff

    International Nuclear Information System (INIS)

    Jackson, J.L.; Gram, H.F.; Hong, K.J.; Ng, H.S.; Pendergrass, A.M.

    1984-01-01

    The Nevada Nuclear Waste Storage Investigations (NNWSI) Project is conducting investigations to determine the suitability of a site at Yucca Mountain for development as a high level waste repository. In support of the conceptual design, a preliminary analysis has been performed to identify events that could cause radiological releases from the surface facilities during the operations period. Accidental releases were modeled as short-duration release plumes, dispersed under averaged climatic conditions, using the AIRDOS-EPA code. The consequences of these accidents, in 50-yr integrated dose commitments to operations personnel, to the maximally exposed member of the public, and to the general population in the surrounding area were calculated. The risk to the general public from each event was also assessed. All postulated accidents result in doses to members of the public that are lower than the 0.5 rem/accident limit set by the NRC in 10 CFR 60. For those accidents that do not involve both fire and breach of waste canisters, doses to operations personnel are within the NRC limit for routine operations of 5 rem/yr set in 10 CFR 20. Accidents that involve fire and breach of waste canisters may cause doses to some operations personnel that are in excess of this limit. 18 references, 1 figure, 3 tables

  9. Imaging and radiology

    Science.gov (United States)

    Interventional radiology; Diagnostic radiology; X-ray imaging ... DIAGNOSTIC RADIOLOGY Diagnostic radiology helps health care professionals see structures inside your body. Doctors that specialize in the interpretation ...

  10. Chronicle of pediatric radiology

    International Nuclear Information System (INIS)

    Benz-Bohm, Gabriele; Richter, Ernst

    2012-01-01

    The chronicle of pediatric radiology covers the following issues: Development of pediatric radiology in Germany (BRD, DDR, pediatric radiological accommodations); development of pediatric radiology in the Netherlands (chronology and pediatric radiological accommodations); development of pediatric radiology in Austria (chronology and pediatric radiological accommodations); development of pediatric radiology in Switzerland (chronology and pediatric radiological accommodations).

  11. The reliability and validity of radiological assessment for patellar instability. A systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Toby O. [University of East Anglia, Faculty of Health, Norwich (United Kingdom); Davies, Leigh [Norfolk and Norwich University Hospital, Norwich (United Kingdom); Toms, Andoni P.; Donell, Simon T. [University of East Anglia, Faculty of Health, Norwich (United Kingdom); Norfolk and Norwich University Hospital, Norwich (United Kingdom); Hing, Caroline B. [St George' s Hospital, London (United Kingdom)

    2011-04-15

    To determine the discriminative validity and reliability of the evidence base using meta-analysis. A review of published sources using the databases AMED, CINHAL, EMBASE, MEDLINE, Scopus and the Cochrane Library, and for unpublished material was conducted. All studies assessing the reliability, validity, sensitivity or specificity of magnetic resonance imaging (MRI), computed tomography (CT) or ultrasound (US) of the patellofemoral joint of patients following patellar dislocation, subluxation or instability, were included. A meta-analysis was performed to assess the difference in radiological measurements between healthy controls and subjects with patellar instability in order to assess discrimination validity. A narrative assessment was used to evaluate the inter- and intra-observer reliability as well as the sensitivity and specificity of specific radiological measurements. A total of 27 studies were reviewed. The findings indicated that there was acceptable inter-observer and intra-observer reliability and validity for different methods of assessing patellar height and the sulcus angle with X-ray, MRI and CT methods, and the tibial tubercle-trochlear groove (TT-TG) assessed using CT. There was poor reliability or validity for the assessment of severity of trochlear dysplasia and the sulcus angle using US. There is insufficient evidence to determine the reliability, validity, sensitivity or specificity of tests such as the congruence angle, lateral patellar displacement, lateral patellar tilt, trochlear depth, boss height, the crossing sign or Wiberg patellar classification. A critical appraisal of the literature identified a number of recurrent methodological limitations. Further study is recommended to evaluate the reliability and validity of these radiological outcomes using well-designed radiological trials. (orig.)

  12. The reliability and validity of radiological assessment for patellar instability. A systematic review and meta-analysis

    International Nuclear Information System (INIS)

    Smith, Toby O.; Davies, Leigh; Toms, Andoni P.; Donell, Simon T.; Hing, Caroline B.

    2011-01-01

    To determine the discriminative validity and reliability of the evidence base using meta-analysis. A review of published sources using the databases AMED, CINHAL, EMBASE, MEDLINE, Scopus and the Cochrane Library, and for unpublished material was conducted. All studies assessing the reliability, validity, sensitivity or specificity of magnetic resonance imaging (MRI), computed tomography (CT) or ultrasound (US) of the patellofemoral joint of patients following patellar dislocation, subluxation or instability, were included. A meta-analysis was performed to assess the difference in radiological measurements between healthy controls and subjects with patellar instability in order to assess discrimination validity. A narrative assessment was used to evaluate the inter- and intra-observer reliability as well as the sensitivity and specificity of specific radiological measurements. A total of 27 studies were reviewed. The findings indicated that there was acceptable inter-observer and intra-observer reliability and validity for different methods of assessing patellar height and the sulcus angle with X-ray, MRI and CT methods, and the tibial tubercle-trochlear groove (TT-TG) assessed using CT. There was poor reliability or validity for the assessment of severity of trochlear dysplasia and the sulcus angle using US. There is insufficient evidence to determine the reliability, validity, sensitivity or specificity of tests such as the congruence angle, lateral patellar displacement, lateral patellar tilt, trochlear depth, boss height, the crossing sign or Wiberg patellar classification. A critical appraisal of the literature identified a number of recurrent methodological limitations. Further study is recommended to evaluate the reliability and validity of these radiological outcomes using well-designed radiological trials. (orig.)

  13. A preliminary analysis of the reactor-based plutonium disposition alternative deployment schedules

    International Nuclear Information System (INIS)

    Zurn, R.M.

    1997-09-01

    This paper discusses the preliminary analysis of the implementation schedules of the reactor-based plutonium disposition alternatives. These schedule analyses are a part of a larger process to examine the nine decision criteria used to determine the most appropriate method of disposing of U.S. surplus weapons plutonium. The preliminary analysis indicates that the mission durations for the reactor-based alternatives range from eleven years to eighteen years and the initial mission fuel assemblies containing surplus weapons-usable plutonium could be loaded into the reactors between nine and fourteen years after the Record of Decision

  14. Purification, crystallization and preliminary X-ray structure analysis of the laccase from Ganoderma lucidum

    International Nuclear Information System (INIS)

    Lyashenko, Andrey V.; Belova, Oksana; Gabdulkhakov, Azat G.; Lashkov, Alexander A.; Lisov, Alexandr V.; Leontievsky, Alexey A.; Mikhailov, Al’bert M.

    2011-01-01

    The purification, crystallization and preliminary X-ray structure analysis of the laccase from G. lucidum are reported. The ligninolytic enzymes of the basidiomycetes play a key role in the global carbon cycle. A characteristic property of these enzymes is their broad substrate specificity, which has led to their use in various biotechnologies, thus stimulating research into the three-dimensional structures of ligninolytic enzymes. This paper presents the purification, crystallization and preliminary X-ray analysis of the laccase from the ligninolytic basidiomycete Ganoderma lucidum

  15. NRC staff preliminary analysis of public comments on advance notice of proposed rulemaking on emergency planning

    International Nuclear Information System (INIS)

    Peabody, C.A.; Hickey, J.W.N.

    1980-01-01

    The Nuclear Regulatory Commission (NRC) published an advance notice of proposed rulemaking on emergency planning on July 17, 1979 (44 FR 41483). In October and November 1979, the NRC staff submitted several papers to the Commission related to the emergency planning rulemaking. One of these papers was a preliminary analysis of public comments received on the advance notice (SECY-79-591B, November 13, 1979). This document consists of the preliminary analysis as it was submitted to the Commission, with minor editorial changes

  16. Thick Concrete Specimen Construction, Testing, and Preliminary Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, Dwight A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hoegh, Kyle [Univ. of Minnesota, Minneapolis, MN (United States); Khazanovich, Lev [Univ. of Minnesota, Minneapolis, MN (United States)

    2015-03-01

    The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years. Since many important safety structures in an NPP are constructed of concrete, inspection techniques must be developed and tested to evaluate the internal condition. In-service containment structures generally do not allow for the destructive measures necessary to validate the accuracy of these inspection techniques. This creates a need for comparative testing of the various nondestructive evaluation (NDE) measurement techniques on concrete specimens with known material properties, voids, internal microstructure flaws, and reinforcement locations. A preliminary report detailed some of the challenges associated with thick reinforced concrete sections and prioritized conceptual designs of specimens that could be fabricated to represent NPP concrete structures for using in NDE evaluation comparisons. This led to the construction of the concrete specimen presented in this report, which has sufficient reinforcement density and cross-sectional size to represent an NPP containment wall. Details on how a suitably thick concrete specimen was constructed are presented, including the construction materials, final nominal design schematic, as well as formwork and rigging required to safely meet the desired dimensions of the concrete structure. The report also details the type and methods of forming the concrete specimen as well as information on how the rebar and simulated defects were embedded. Details on how the resulting specimen was transported, safely anchored, and marked to allow access for systematic comparative NDE testing of defects in a representative NPP containment wall concrete specimen are also given. Data collection using the MIRA Ultrasonic NDE equipment and

  17. Health literacy in vascular and interventional radiology: a comparative analysis of online patient education resources.

    Science.gov (United States)

    Hansberry, David R; Kraus, Carl; Agarwal, Nitin; Baker, Stephen R; Gonzales, Sharon F

    2014-08-01

    The Internet is frequently accessed by patients as a resource for medical knowledge. However, the provided material is typically written at a level well above the recommended 7th grade level. A clear understanding of the capabilities, limitations, risks, and benefits of interventional radiology by patients, both current and prospective, is hindered when the textual information offered to the public is pitched at a level of sophistication too high for general comprehension. In January 2013, all 25 patient education resources from the Cardiovascular and Interventional Radiology Society of Europe (CIRSE) Web site ( http://www.cirse.org ) and all 31 resources from the Society of Interventional Radiology (SIR) Web site ( http://www.sirweb.org ) were analyzed for their specific level of readability using ten quantitative scales: Flesch Reading Ease, Flesch-Kincaid Grade Level, Simple Measure of Gobbledygook, Gunning fog index, New Fog Count, Coleman-Liau index, FORCAST formula, Fry graph, Raygor Readability Estimate, and New Dale-Chall. Collectively, the patient education resources on the CIRSE Web site are written at the 12.3 grade level, while the resources on the SIR Web site are written at the 14.5 grade level. Educational health care materials available on both the CIRSE and the SIR Web sites are presented in language in the aggregate that could be too difficult for many lay people to fully understand. Given the complex nature of vascular and interventional radiology, it may be advantageous to rewrite these educational resources at a lower reading level to increase comprehension.

  18. The most downloaded and most cited articles in radiology journals: a comparative bibliometric analysis.

    Science.gov (United States)

    Baek, Sora; Yoon, Dae Young; Lim, Kyoung Ja; Cho, Young Kwon; Seo, Young Lan; Yun, Eun Joo

    2018-05-07

    To evaluate and compare the characteristics of the most downloaded and most cited articles in radiology journals. We selected 41 radiology journals that provided lists of both the most downloaded and most cited articles on their websites, and identified the 596 most downloaded articles and 596 most cited articles. We compared the following characteristics of the most downloaded and most cited articles: year of publication, journal title, department of the first author, country of origin, publication type, radiologic subspecialty, radiologic technique and accessibility. Compared to the most cited articles, the most downloaded articles were more frequently review articles (36.1% vs 17.1%, p articles, the most downloaded articles more frequently originated from the UK (8.7% vs 5.0%, p articles (46.0% vs 39.4%, p articles are more frequent among the most downloaded articles. • There was only small overlap between the most downloaded and most cited articles. • Educational articles were more frequent among the most downloaded articles. • Free-access articles are more frequent among the most downloaded articles.

  19. Analysis of radiological examination request forms in conjunction with justification of X-ray exposures

    International Nuclear Information System (INIS)

    Triantopoulou, Ch.; Tsalafoutas, I.; Maniatis, P.; Papavdis, D.; Raios, G.; Siafas, I.; Velonakis, S.; Koulentianos, E.

    2005-01-01

    Objectives: To evaluate the adequacy of patient data and clinical information transmitted to the radiological departments by the referring clinicians in view of the justification demands concerning the radiological examinations, as those are described in the Radiation Protection Regulations of the European Union Nations. Materials and methods: Request forms for 1708 patients referred to radiology department and 410 referred to the CT department were evaluated concerning the proper completion of the form fields. Furthermore, for CT examinations a more detailed evaluation was carried out, to assess the rationalistic use of CT within the diagnostic algorithm. Results: Not properly completed request forms to both departments were observed, however, the omissions were more prominent for the referrals to the radiology department, where the age and the probable clinical diagnosis was not given in 81.5 and 46% of the forms, respectively. Furthermore, the emergency indication was less cautiously used compared to the CT requests. For the CT department 33.3% of requests were justified and the final diagnosis was included in the referring doctor's probable clinical diagnosis. U/S was the examination of choice in 51% of the cases where an examination should have been performed before CT and in 70.6% of the cases where an alternative examination was proposed. Conclusions: The inadequate transmission of clinical information and the large number of not fully justified CT requests observed in this study are typical examples of the various problems that radiologists have to face in order to apply the justification directives

  20. Wrong decisions in radiology. Analysis of causes and strategies for error prevention

    International Nuclear Information System (INIS)

    Lackner, Klaus-Juergen; Krug, Kathrin Barbara

    2009-01-01

    The book covers observations on errors concerning radiological decisions within a ten-year period. The compiled information is supposed to prevent similar errors in the future. The case studies cover the following issues: cranium, thorax, mamma, abdomen (liver, pancreas, colon), (gastrointestinal tract, urogenital tract), spinal cord, skeleton and blood vessels.

  1. Occupational Analysis: Hospital Radiologic Technologist. The UCLA Allied Health Professions Project.

    Science.gov (United States)

    Reeder, Glenn D.; And Others

    In an effort to meet the growing demand for skilled radiologic technologists and other supportive personnel educated through the associate degree level, a national survey was conducted as part of the UCLA Allied Health Professions Project to determine the tasks performed by personnel in the field and lay the groundwork for development of…

  2. Analysis of conditions to safety and radiological protection of Brazilian research particle accelerators facilities

    International Nuclear Information System (INIS)

    Lourenco, Manuel Jacinto Martins

    2010-01-01

    Eleven institutions of education and research in Brazil use particle accelerators, which fulfill different functions and activities. Currently, these institutions employ a total of fifteen accelerators. In this paper, the object of study is the radiological protection of occupationally exposed individuals, the general public and the radiation safety of particle accelerators. Research facilities with accelerators are classified in categories I and II according to the International Atomic Energy Agency or groups IX and X in accordance with the Brazilian National Commission of Nuclear Energy. Of the 15 accelerators in use for research in Brazil, four belong to category I or group X and eleven belong to category II or group IX. The methodology presented and developed in this work was made through the inspection and assessment of safety and radiological protection of thirteen particle accelerators facilities, and its main purpose was to promote safer use of this practice by following established guidelines for safety and radiological protection. The results presented in this work showed the need to create a program, in our country, for the control of safety and radiological protection of this ionizing radiation practice. (author)

  3. Radiologic protection in dental radiology

    International Nuclear Information System (INIS)

    Pacheco Jimenez, R.E.; Bermudez Jimenez, L.A.

    2000-01-01

    With this work and employing the radioprotection criterion, the authors pretend to minimize the risks associated to this practice; without losing the quality of the radiologic image. Odontology should perform the following criterions: 1. Justification: all operation of practice that implies exposition to radiations, should be reweighed, through an analysis of risks versus benefits, with the purpose to assure, that the total detriment will be small, compared to resultant benefit of this activity. 2. Optimization: all of the exposures should be maintained as low as reasonable possible, considering the social and economic factors. 3. Dose limit: any dose limit system should be considered as a top condition, nota as an admissible level. (S. Grainger)

  4. Source term derivation and radiological safety analysis for the TRICO II research reactor in Kinshasa

    International Nuclear Information System (INIS)

    Muswema, J.L.; Ekoko, G.B.; Lukanda, V.M.; Lobo, J.K.-K.; Darko, E.O.; Boafo, E.K.

    2015-01-01

    Highlights: • Atmospheric dispersion modeling for two credible accidents of the TRIGA Mark II research reactor in Kinshasa (TRICO II) was performed. • Radiological safety analysis after the postulated initiating events (PIE) was also carried out. • The Karlsruhe KORIGEN and the HotSpot Health Physics codes were used to achieve the objectives of this study. • All the values of effective dose obtained following the accident scenarios were below the regulatory limits for reactor staff members and the public, respectively. - Abstract: The source term from the 1 MW TRIGA Mark II research reactor core of the Democratic Republic of the Congo was derived in this study. An atmospheric dispersion modeling followed by radiation dose calculation were performed based on two possible postulated accident scenarios. This derivation was made from an inventory of peak radioisotope activities released in the core by using the Karlsruhe version of isotope generation code KORIGEN. The atmospheric dispersion modeling was performed with HotSpot code, and its application yielded to radiation dose profile around the site using meteorological parameters specific to the area under study. The two accident scenarios were picked from possible accident analyses for TRIGA and TRIGA-fueled reactors, involving the case of destruction of the fuel element with highest activity release and a plane crash on the reactor building as the worst case scenario. Deterministic effects of these scenarios are used to update the Safety Analysis Report (SAR) of the reactor, and for its current version, these scenarios are not yet incorporated. Site-specific meteorological conditions were collected from two meteorological stations: one installed within the Atomic Energy Commission and another at the National Meteorological Agency (METTELSAT), which is not far from the site. Results show that in both accident scenarios, radiation doses remain within the limits, far below the recommended maximum effective

  5. Source term derivation and radiological safety analysis for the TRICO II research reactor in Kinshasa

    Energy Technology Data Exchange (ETDEWEB)

    Muswema, J.L., E-mail: jeremie.muswem@unikin.ac.cd [Faculty of Science, University of Kinshasa, P.O. Box 190, KIN XI (Congo, The Democratic Republic of the); Ekoko, G.B. [Faculty of Science, University of Kinshasa, P.O. Box 190, KIN XI (Congo, The Democratic Republic of the); Lukanda, V.M. [Faculty of Science, University of Kinshasa, P.O. Box 190, KIN XI (Congo, The Democratic Republic of the); Democratic Republic of the Congo' s General Atomic Energy Commission, P.O. Box AE1 (Congo, The Democratic Republic of the); Lobo, J.K.-K. [Faculty of Science, University of Kinshasa, P.O. Box 190, KIN XI (Congo, The Democratic Republic of the); Darko, E.O. [Radiation Protection Institute, Ghana Atomic Energy Commission, P.O. Box LG 80, Legon, Accra (Ghana); Boafo, E.K. [University of Ontario Institute of Technology, 2000 Simcoe St. North, Oshawa, ONL1 H7K4 (Canada)

    2015-01-15

    Highlights: • Atmospheric dispersion modeling for two credible accidents of the TRIGA Mark II research reactor in Kinshasa (TRICO II) was performed. • Radiological safety analysis after the postulated initiating events (PIE) was also carried out. • The Karlsruhe KORIGEN and the HotSpot Health Physics codes were used to achieve the objectives of this study. • All the values of effective dose obtained following the accident scenarios were below the regulatory limits for reactor staff members and the public, respectively. - Abstract: The source term from the 1 MW TRIGA Mark II research reactor core of the Democratic Republic of the Congo was derived in this study. An atmospheric dispersion modeling followed by radiation dose calculation were performed based on two possible postulated accident scenarios. This derivation was made from an inventory of peak radioisotope activities released in the core by using the Karlsruhe version of isotope generation code KORIGEN. The atmospheric dispersion modeling was performed with HotSpot code, and its application yielded to radiation dose profile around the site using meteorological parameters specific to the area under study. The two accident scenarios were picked from possible accident analyses for TRIGA and TRIGA-fueled reactors, involving the case of destruction of the fuel element with highest activity release and a plane crash on the reactor building as the worst case scenario. Deterministic effects of these scenarios are used to update the Safety Analysis Report (SAR) of the reactor, and for its current version, these scenarios are not yet incorporated. Site-specific meteorological conditions were collected from two meteorological stations: one installed within the Atomic Energy Commission and another at the National Meteorological Agency (METTELSAT), which is not far from the site. Results show that in both accident scenarios, radiation doses remain within the limits, far below the recommended maximum effective

  6. Analysis of nuclear and radiological events. Textbook for lecture in graduate school of engineering in the University of Tokyo

    International Nuclear Information System (INIS)

    Watanabe, Norio

    2007-02-01

    The Japan Atomic Energy Agency is carrying out the cooperative activity by providing specialized educational and training staff and making our facilities available for the graduate school of engineering in The University of Tokyo as part of developing human resources in nuclear technology. This report is prepared as a textbook for the lecture in the graduate school of engineering in The University of Tokyo and provides the outlines of activities on the analysis of nuclear and radiological events and analysis methods as well as the summaries of major incidents and accidents that occurred. (author)

  7. [Controlling instruments in radiology].

    Science.gov (United States)

    Maurer, M

    2013-10-01

    Due to the rising costs and competitive pressures radiological clinics and practices are now facing, controlling instruments are gaining importance in the optimization of structures and processes of the various diagnostic examinations and interventional procedures. It will be shown how the use of selected controlling instruments can secure and improve the performance of radiological facilities. A definition of the concept of controlling will be provided. It will be shown which controlling instruments can be applied in radiological departments and practices. As an example, two of the controlling instruments, material cost analysis and benchmarking, will be illustrated.

  8. Preliminary Coupling of MATRA Code for Multi-physics Analysis

    International Nuclear Information System (INIS)

    Kim, Seongjin; Choi, Jinyoung; Yang, Yongsik; Kwon, Hyouk; Hwang, Daehyun

    2014-01-01

    The boundary conditions such as the inlet temperature, mass flux, averaged heat flux, power distributions of the rods, and core geometry is given by constant values or functions of time. These conditions are separately calculated and provided by other codes, such as a neutronics or a system codes, into the MATRA code. In addition, the coupling of several codes in the different physics field is focused and embodied. In this study, multiphysics coupling methods were developed for a subchannel code (MATRA) with neutronics codes (MASTER, DeCART) and a fuel performance code (FRAPCON-3). Preliminary evaluation results for representative sample cases are presented. The MASTER and DeCART codes provide the power distribution of the rods in the core to the MATRA code. In case of the FRAPCON-3 code, the variation of the rod diameter induced by the thermal expansion is yielded and provided. The MATRA code transfers the thermal-hydraulic conditions that each code needs. Moreover, the coupling method with each code is described

  9. Seismic response of transamerical building. I. Data and preliminary analysis

    Science.gov (United States)

    Celebi, M.; Safak, E.

    1991-01-01

    The objective of this paper is to present preliminary analyses of a set of acceleration response records obtained during the October 17, 1989 Loma Prieta earthquake (Ms = 7.1) from the 60-story vertically tapered, pyramid-shaped Trans-america Building-a landmark of San Francisco. The building was instrumented in 1985 with 22 channels of synchronized sensors consisting of 13 uniaxial accelerometers deployed throughout the structure and connected to a central recording system and three triaxial strong-motion accelerographs at three different levels of the structure. No free-field accelerographs are at the site. The acceleration records permit the study of the behavior of this unique structure. The predominant translational response of the building and the associated frequency at approximately 0.28 Hz are identified from the records and their Fourier amplitude spectra. The records do not indicate any significant torsional motion. However, there is rocking type soil-structure interaction, and an associated frequency of approximately 2.0 Hz is identified from the Fourier amplitude spectra of the differential motions between the ground level and that at the basement. In addition, the response spectra for the basement motions indicate significant resonance in both directions at a period of approximately 0.5 seconds.

  10. Preliminary Analysis of Species Partitioning in the DWPF Melter

    Energy Technology Data Exchange (ETDEWEB)

    Choi, A. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Kesterson, M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Johnson, F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); McCabe, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-07-15

    The work described in this report is preliminary in nature since its goal was to demonstrate the feasibility of estimating the off-gas entrainment rates from the Defense Waste Processing Facility (DWPF) melter based on a simple mass balance using measured feed and glass pour stream compositions and timeaveraged melter operating data over the duration of one canister-filling cycle. The only case considered in this study involved the SB6 pour stream sample taken while Canister #3472 was being filled over a 20-hour period on 12/20/2010, approximately three months after the bubblers were installed. The analytical results for that pour stream sample provided the necessary glass composition data for the mass balance calculations. To estimate the “matching” feed composition, which is not necessarily the same as that of the Melter Feed Tank (MFT) batch being fed at the time of pour stream sampling, a mixing model was developed involving three preceding MFT batches as well as the one being fed at that time based on the assumption of perfect mixing in the glass pool but with an induction period to account for the process delays involved in the calcination/fusion step in the cold cap and the melter turnover.

  11. Fukushima Daiichi unit 1 uncertainty analysis--Preliminary selection of uncertain parameters and analysis methodology

    Energy Technology Data Exchange (ETDEWEB)

    Cardoni, Jeffrey N.; Kalinich, Donald A.

    2014-02-01

    Sandia National Laboratories (SNL) plans to conduct uncertainty analyses (UA) on the Fukushima Daiichi unit (1F1) plant with the MELCOR code. The model to be used was developed for a previous accident reconstruction investigation jointly sponsored by the US Department of Energy (DOE) and Nuclear Regulatory Commission (NRC). However, that study only examined a handful of various model inputs and boundary conditions, and the predictions yielded only fair agreement with plant data and current release estimates. The goal of this uncertainty study is to perform a focused evaluation of uncertainty in core melt progression behavior and its effect on key figures-of-merit (e.g., hydrogen production, vessel lower head failure, etc.). In preparation for the SNL Fukushima UA work, a scoping study has been completed to identify important core melt progression parameters for the uncertainty analysis. The study also lays out a preliminary UA methodology.

  12. Gastrointestinal transit after transverse colostomy: study of solid radiopaque markers progression and others clinical and radiological events - analysis of 20 cases

    International Nuclear Information System (INIS)

    Deutsch, Claudio Roberto

    1988-01-01

    The gastrointestinal transit was studied in 20 patients with loop transverse colostomies and previously normal colons. This analysis was performed through radiological observation of progression of 20 radiopaque pellets and measurements of its transit time in the various segments of the digestive tract. An evaluation of other related clinical and radiological events was carried out sentimentality's. In order to better understand the influence of the surgical procedure, the study was performed under similar dietary and supportive care conditions and standard radiological studies before and after the re-establishment of transit, thus enabling a comparison with the same individual. (author)

  13. Dental radiology

    International Nuclear Information System (INIS)

    Bhaskar, S.N.

    1982-01-01

    The book presents the radiological manifestations of the maxillodental region in a suitable manner for fast detection and correct diagnosing of diseases of the teeth, soft tissue, and jaws. Classification therefore is made according to the radiological manifestations of the diseases and not according to etiology. (orig./MG) [de

  14. Preliminary Experimental Analysis of Soil Stabilizers for Contamination Control

    International Nuclear Information System (INIS)

    Lagos, L.; Varona, J.; Zidan, A.; Gudavalli, R.; Wu, Kuang-His

    2006-01-01

    A major focus of Department of Energy's (DOE's) environmental management mission at the Hanford site involves characterizing and remediating contaminated soil and groundwater; stabilizing contaminated soil; remediating disposal sites; decontaminating and decommissioning structures, and demolishing former plutonium production process buildings, nuclear reactors, and separation plants; maintaining inactive waste sites; transitioning facilities into the surveillance and maintenance program; and mitigating effects to biological and cultural resources from site development and environmental cleanup and restoration activities. For example, a total of 470,914 metric tons of contaminated soil from 100 Areas remediation activities were disposed at the Environmental Restoration Disposal Facility (ERDF) during 2004. The Applied Research Center (ARC) at Florida International University (FIU) is supporting the Hanford's site remediation program by analyzing the effectiveness of several soil stabilizers (fixatives) for contamination control during excavation activities. The study is focusing on determining the effects of varying soil conditions, temperature, humidity and wind velocity on the effectiveness of the candidate stabilizers. The test matrix consists of a soil penetration-depth study, wind tunnel experiments for determination of threshold velocity, and temperature and moisture-controlled drying/curing experiments. These three set of experiments are designed to verify performance metrics, as well as provide insight into what fundamental forces are altered by the use of the stabilizer. This paper only presents the preliminary results obtained during wind tunnel experiments using dry Hanford soil samples (with 2.7% moisture by weight). These dry soil samples were exposed to varying wind speeds from 2.22 m/sec to 8.88 m/sec. Furthermore, airborne particulate data was collected for the dry Hanford soil experiments using an aerosol analyzer instrument. (authors)

  15. Preliminary study of elemental analysis of hydroxyapatite used neutron activation analysis method

    International Nuclear Information System (INIS)

    Yustinus Purwamargapratala; Rina Mulyaningsih

    2010-01-01

    Preliminary study has been carried out elemental analysis of hydroxyapatite synthesized using the method of neutron activation analysis. Hydroxyapatite is the main component constituent of bones and teeth which can be synthesized from limestone and phosphoric acid. Hydroxyapatite can be used as a bone substitute material and human and animal teeth. Tests on the metal content is necessary to prevent the risk of damage to bones and teeth due to contamination. Results of analysis using neutron activation analysis method with samples irradiated at the neutron flux 10"3 n.det"-"1cm"-"2 for one minute, the impurities of Al (48.60±6.47 mg/kg), CI (38.00±7.47 mg/kg), Mn (1.05±0.19 mg/kg), and Mg (2095.30±203.66 mg/kg), were detected, whereas with irradiation time for 10 minutes and 40 minutes with a time decay of three days there were K (103.89 ± 26.82 mg/kg), Br (1617.06 ± 193.66 mg/kg), and Na (125.10±9.57 mg/kg). These results indicate that there is impurity Al, CI, Mn, Mg, Br, K and Na, although in very small amounts and do not cause damage to bones and teeth. (author)

  16. Analysis of papers in the journal of Korean radiologic society of recent three years with special emphasis on citation index

    International Nuclear Information System (INIS)

    Yang, Seoung Oh; Choi, Sang Hee; Jeong, Cheol Hwe; Lee, Yung Il

    1990-01-01

    The papers in the Journal of the Korean Radiologic Society (JKRS) during recent three years were surveyed by analysis of their types, topics, organs, employed modalities, and cited literatures. Citation analysis is a method of studying interrelationships between papers and journals, and the most important application of citation analysis is in studies of science policy and research evaluation to evaluate the implementation of science policy and to monitor research performance. Using these citation analysis to map the journal communications network may indicate to more efficient scientific progress. Total number of papers published by JKRS for recent 3 years was 473 papers (Clinical : 354, Case report : 91, Experimental : 26, Educational : 2). The most common organ system of the papers was abdomen (head and neck, chest, musculoskeletal, cardiovascular, and urologic system in the order of decreasing frequency). The most popular topic was techniques including newer modalities and interventional radiology, and normal measurement, tuberculosis, hepatoma, normal anatomy and the like followed. Total number of cited references was 8,642 (18.26 per one paper), and the average number of authors per paper was 4.83. The most frequently used modality was CT (41%) followed by simple radiography, ultrasonogram, fluoroscopic study, angiography, nuclear imaging, and MRI. Using this kind of analysis as a guide for writing a paper for the JKRS, it could be well-organized and uplifted in its format and contents

  17. Chemical Analysis of the Moon at the Surveyor VI Landing Site: Preliminary Results.

    Science.gov (United States)

    Turkevich, A L; Patterson, J H; Franzgrote, E J

    1968-06-07

    The alpha-scattering experiment aboard soft-landing Surveyor VI has provided a chemical analysis of the surface of the moon in Sinus Medii. The preliminary results indicate that, within experimental errors, the composition is the same as that found by Surveyor V in Mare Tranquillitatis. This finding suggests that large portions of the lunar maria resemble basalt in composition.

  18. Chemical Analysis of the Moon at the Surveyor VII Landing Site: Preliminary Results.

    Science.gov (United States)

    Turkevich, A L; Franzgrote, E J; Patterson, J H

    1968-10-04

    The alpha-scattering experiment aboard Surveyor VII has provided a chemical analysis of the moon in the area of the crater Tycho. The preliminary results indicate a chemical composition similar to that already found at two mare sites, but with a lower concentration of elements of the iron group (titanium through copper).

  19. Current Mooring Design in Partner WECs and Candidates for Preliminary Analysis

    DEFF Research Database (Denmark)

    Thomsen, Jonas Bjerg; Ferri, Francesco; Kofoed, Jens Peter

    This report is the combined report of Commercial Milestone "CM1: Design and Cost of Current Mooring Solutions of Partner WECs" and Milestone "M3: Mooring Solutions for Preliminary Analysis" of the EUDP project "Mooring Solutions for Large Wave Energy Converters". The report covers a description o...

  20. ANSI/ASHRAE/IES Standard 90.1-2013 Preliminary Determination: Quantitative Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Halverson, Mark A.; Rosenberg, Michael I.; Wang, Weimin; Zhang, Jian; Mendon, Vrushali V.; Athalye, Rahul A.; Xie, YuLong; Hart, Reid; Goel, Supriya

    2014-03-01

    This report provides a preliminary quantitative analysis to assess whether buildings constructed according to the requirements of ANSI/ASHRAE/IES Standard 90.1-2013 would result in energy savings compared with buildings constructed to ANSI/ASHRAE/IES Standard 90.1-2010.

  1. Preliminary fire hazard analysis for the PUTDR and TRU trenches in the Solid Waste Burial Ground

    International Nuclear Information System (INIS)

    Gaschott, L.J.

    1995-01-01

    This document represents the Preliminary Fire Hazards Analysis for the Pilot Unvented TRU Drum Retrieval effort and for the Transuranic drum trenches in the low level burial grounds. The FHA was developed in accordance with DOE Order 5480.7A to address major hazards inherent in the facility

  2. A Preliminary Analysis of the Outcomes of Students Assisted by VET FEE-HELP: Summary

    Science.gov (United States)

    National Centre for Vocational Education Research (NCVER), 2015

    2015-01-01

    This summary highlights the key findings from the report "A preliminary analysis of the outcomes of students assisted by VET FEE-HELP". VET FEE-HELP is an income-contingent loan scheme that assists eligible students undertaking certain vocational education training (VET) courses with an approved provider by paying for all or part of…

  3. Expression, purification, crystallization and preliminary X-ray analysis of Aeromonas hydrophilia metallo-β-lactamase

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Nandini, E-mail: nandini-sharma@merck.com; Toney, Jeffrey H.; Fitzgerald, Paula M. D.

    2005-02-01

    Crystallization and preliminary X-ray analysis of the CphA metallo-β-lactamase from A. hydrophilia are described. The crystals belonged to space group P2{sub 1}2{sub 1}2, with unit-cell parameters a = 40.75, b = 42.05, c = 128.88 Å, and diffract to 1.8 Å.

  4. Preliminary safety analysis of unscrammed events for KLFR

    International Nuclear Information System (INIS)

    Kim, S.J.; Ha, G.S.

    2005-01-01

    The report presents the design features of KLFR; Safety Analysis Code; steady-state calculation results and analysis results of unscrammed events. The calculations of the steady-state and unscrammed events have been performed for the conceptual design of KLFR using SSC-K code. UTOP event results in no fuel damage and no centre-line melting. The inherent safety features are demonstrated through the analysis of ULOHS event. Although the analysis of ULOF has much uncertainties in the pump design, the analysis results show the inherent safety characteristics. 6% flow of rated flow of natural circulation is formed in the case of ULOF. In the metallic fuel rod, the cladding temperature is somewhat high due to the low heat transfer coefficient of lead. ULOHS event should be considered in design of RVACS for long-term cooling

  5. Preliminary results of system emergency program to radiologic events of Distrito Federal; Resultados preliminares do programa de atendimento a eventos de origem radiologica no Distrito Federal

    Energy Technology Data Exchange (ETDEWEB)

    Correa, Rosangela da Silveira; Dias, Cintia Melazo; Nicoli, Ieda Gomes [CNEN, Brasilia, DF (Brazil)

    1997-12-31

    This paper intends to present the program conducted by Comissao Nacional de Energia Nuclear (CNEN) in Brasilia related to the controlling of unusual situations involving radiation sources in Distrito Federal. The CNEN in Brasilia has been working in this program since 1994. In this way people has used two mechanisms to contacted, telephone and pager. In 1994, there was one denunciation, five in 1995 and twenty in 1996. The device found in Distrito Federal were: radioactive lightning rod, dentistry and medical X-rays equipment, smoke detectors, research and toxic material. In a period of three years, 1994 to 1996, the radioactive lightning rod an dentistry and medical X-rays equipment represented seventy per cent of all material found. Distrito Federal has never had a real radiological emergency situation but radiological events because, up to now, it has not have lost of control of a radioactive source. The problem that emerges is a psychological. The radioactive symbol found in the material frightens the population. The results show that an emergency planning is necessary in Distrito Federal once that the events occurred since 1996 represented thirty per cent of all events occurred in national territory. (author) 6 refs., 3 figs.; e-mail: cnenbsb at rio.nutecnet.com.br

  6. Preliminary mortality survey from 1973 to 1977 of Japanese radiological technologists and analyses of the association of mortality with cumulative doses

    International Nuclear Information System (INIS)

    Aoyama, Takashi; Ishizaka, Masatsuna; Yamamoto, Yoichi; Kano, Eiichi; Nikaido, Osamu.

    1981-01-01

    The Japan Association of Radiologic Technologists reported that, from 1941 to 1978, 395 deaths occurred among Japanese radiological technologists who belong to the association. Using these data, Sakka, Kitabatake and colleagues, and the present authors studied mortality and cause of death among these technologists for 11 years from 1955 to 1965, for 7 years from 1966 to 1972, and for 5 years from 1973 to 1977, respectively. In general, the number of cancer deaths in the three studies was less than expected. However, Kitabatake et al. and the present authors found that deaths from skin cancer were significantly more frequent than expected. The present authors recently estimated the cumulative doses of radiation exposure for the majority of deaths (268 out of 395). The mean dose of radiation related to cancer deaths was then compared with that for non-cancer deaths. Also the proportional mortality ratios for cancers were observed in relation to the estimated dose level. In the present study, however, statistical tests to assess for the relationship between mortality and dose of radiation exposure showed no correlation, for the majority of deaths from cancer. (author)

  7. First fungal genome sequence from Africa: A preliminary analysis

    Directory of Open Access Journals (Sweden)

    Rene Sutherland

    2012-01-01

    Full Text Available Some of the most significant breakthroughs in the biological sciences this century will emerge from the development of next generation sequencing technologies. The ease of availability of DNA sequence made possible through these new technologies has given researchers opportunities to study organisms in a manner that was not possible with Sanger sequencing. Scientists will, therefore, need to embrace genomics, as well as develop and nurture the human capacity to sequence genomes and utilise the ’tsunami‘ of data that emerge from genome sequencing. In response to these challenges, we sequenced the genome of Fusarium circinatum, a fungal pathogen of pine that causes pitch canker, a disease of great concern to the South African forestry industry. The sequencing work was conducted in South Africa, making F. circinatum the first eukaryotic organism for which the complete genome has been sequenced locally. Here we report on the process that was followed to sequence, assemble and perform a preliminary characterisation of the genome. Furthermore, details of the computer annotation and manual curation of this genome are presented. The F. circinatum genome was found to be nearly 44 million bases in size, which is similar to that of four other Fusarium genomes that have been sequenced elsewhere. The genome contains just over 15 000 open reading frames, which is less than that of the related species, Fusarium oxysporum, but more than that for Fusarium verticillioides. Amongst the various putative gene clusters identified in F. circinatum, those encoding the secondary metabolites fumosin and fusarin appeared to harbour evidence of gene translocation. It is anticipated that similar comparisons of other loci will provide insights into the genetic basis for pathogenicity of the pitch canker pathogen. Perhaps more importantly, this project has engaged a relatively large group of scientists

  8. Handbook of radiologic procedures

    International Nuclear Information System (INIS)

    Hedgcock, M.

    1986-01-01

    This book is organized around radiologic procedures with each discussed from the points of view of: indications, contraindications, materials, method of procedures and complications. Covered in this book are: emergency radiology chest radiology, bone radiology, gastrointestinal radiology, GU radiology, pediatric radiology, computerized tomography, neuroradiology, visceral and peripheral angiography, cardiovascular radiology, nuclear medicine, lymphangiography, and mammography

  9. Quantitative analysis of the level of readability of online emergency radiology-based patient education resources.

    Science.gov (United States)

    Hansberry, David R; D'Angelo, Michael; White, Michael D; Prabhu, Arpan V; Cox, Mougnyan; Agarwal, Nitin; Deshmukh, Sandeep

    2018-04-01

    The vast amount of information found on the internet, combined with its accessibility, makes it a widely utilized resource for Americans to find information pertaining to medical information. The field of radiology is no exception. In this paper, we assess the readability level of websites pertaining specifically to emergency radiology. Using Google, 23 terms were searched, and the top 10 results were recorded. Each link was evaluated for its readability level using a set of ten reputable readability scales. The search terms included the following: abdominal ultrasound, abdominal aortic aneurysm, aortic dissection, appendicitis, cord compression, CT abdomen, cholecystitis, CT chest, diverticulitis, ectopic pregnancy, epidural hematoma, dural venous thrombosis, head CT, MRI brain, MR angiography, MRI spine, ovarian torsion, pancreatitis, pelvic ultrasound, pneumoperitoneum, pulmonary embolism, subarachnoid hemorrhage, and subdural hematoma. Any content that was not written for patients was excluded. The 230 articles that were assessed were written, on average, at a 12.1 grade level. Only 2 of the 230 articles (1%) were written at the third to seventh grade recommended reading level set forth by the National Institutes of Health (NIH) and American Medical Association (AMA). Fifty-two percent of the 230 articles were written so as to require a minimum of a high school education (at least a 12th grade level). Additionally, 17 of the 230 articles (7.3%) were written at a level that exceeded an undergraduate education (at least a 16th grade level). The majority of websites with emergency radiology-related patient education materials are not adhering to the NIH and AMA's recommended reading levels, and it is likely that the average reader is not benefiting fully from these information outlets. With the link between health literacy and poor health outcomes, it is important to address the online content in this area of radiology, allowing for patient to more fully benefit

  10. Acute traumatic central cord syndrome: analysis of clinical and radiological correlations.

    Science.gov (United States)

    Miranda, P; Gomez, P; Alday, R

    2008-12-01

    In patients with traumatic spinal cord injury, several studies correlate neurological impairment and radiological findings. However, little information is available about this correspondence in the particular group of acute traumatic central cord syndrome. The object of the present work was to describe the clinical and radiological features of a series of patients presenting with acute traumatic central cord syndrome and to analyze clinical and radiological correlations on admission and at last follow-up. Retrospective review of 15 patients diagnosed of acute traumatic central cord syndrome between 1995 and 2005. Global motor score and motor score in upper extremities were determined on admission and at last follow-up (6 months-4 years, mean 16 months). Plain films, cervical computed tomography and magnetic resonance (MR) were performed in every patient and retrieved for the study. In seven patients, serial MR studies were performed during follow-up. Clinical and radiological correlations were statistically analyzed with non-parametric tests. Cervical spondylosis appeared associated with older age, falls, and absence of fracture. Spinal cord edema was the most common finding in MR studies but hemorrhage was also observed. The length of spinal cord edema significantly correlated with initial motor score. The decrease in T2-weighted hyperintensity in serial MR studies correlated with the gain of motor power in upper limbs at last follow-up. Elderly patients with more degenerated cervical spines commonly develop acute traumatic central cord syndrome after incidental falls. Length of spinal cord edema correlates with neurological impairment on admission and may provide significant prognostic information.

  11. Preliminary design analysis of the ALT-II limiter for TEXTOR

    International Nuclear Information System (INIS)

    Koski, J.A.; Boyd, R.D.; Kempka, S.M.; Romig, A.D. Jr.; Smith, M.F.; Watson, R.D.; Whitley, J.B.; Conn, R.W.; Grotz, S.P.

    1984-01-01

    Installation of a large toroidal belt pump limiter, Advanced Limiter Test II (ALT-II), on the TEXTOR tokamak at Juelich, FRG is anticipated for early 1986. This paper discusses the preliminary mechanical design and materials considerations undertaken as part of the feasibility study phase for ALT-II. Since the actively cooled limiter blade is the component in direct contact with the plasma edge, and thus subject to the severe plasma environment, most preliminary design efforts have concentrated on analysis of the blade. The screening process which led to the recommended preliminary design consisting of a dispersion strenghthened copper or OFHC copper cover plate over an austenitic stainless steel base plate is discussed. A 1 to 3 mm thick low atomic number coating consisting of a graded plasma-sprayed Silicon Carbide-Aluminium composite is recommended subject to further experiment and evaluation. Thermal-hydraulic and stress analyses of the limiter blade are also discussed. (orig.)

  12. ORNL: PWR-BDHT analysis procedure, a preliminary overview

    International Nuclear Information System (INIS)

    Cliff, S.B.

    1978-01-01

    The computer programs currently used in the analysis of the ORNL-PWR Blowdown Heat Transfer Separate-Effects Program are overviewed. The current linkages and relationships among the programs are given along with general comments about the future directions of some of these programs. The overview is strictly from the computer science point of view with only minimal information concerning the engineering aspects of the analysis procedure

  13. Controlling the radiological impact in the nuclear fuel cycle: a cost/benefit analysis

    International Nuclear Information System (INIS)

    Blanco, R.E.

    1976-01-01

    Methods that are used to control the radiological impact of the nuclear fuel cycle are discussed. This control is exercised through the application of a series of Federal laws and regulations that are used as the basis for licensing nuclear facilities. These licenses contain technical specifications which define the limits for the release of radioactive materials. The control is exercised more directly in a technical sense by the use of radwaste treatment equipment at the nuclear facilities to limit the release of radioactive materials. The first part of this paper contains a summary of the principal Federal laws and regulations that apply to nuclear fuel cycle facilities and a description of how they are applied in licensing procedures. A detailed discussion is presented of the amounts of radioactive materials that may be released from licensed facilities, and the radiological doses that individuals and populations surrounding these facilities would receive from these releases. These doses are then compared with the radiological doses received from natural background radiation to put them in perspective. Cost/benefit engineering surveys which are being made to determine the cost (in dollars) and the effectiveness of radwaste systems for decreasing the release of radioactive materials from model fuel cycle facilities, and to determine the benefits in terms of reduction in dose commitment to individuals and populations in surrounding areas are described

  14. Prepopulated radiology report templates: a prospective analysis of error rate and turnaround time.

    Science.gov (United States)

    Hawkins, C M; Hall, S; Hardin, J; Salisbury, S; Towbin, A J

    2012-08-01

    Current speech recognition software allows exam-specific standard reports to be prepopulated into the dictation field based on the radiology information system procedure code. While it is thought that prepopulating reports can decrease the time required to dictate a study and the overall number of errors in the final report, this hypothesis has not been studied in a clinical setting. A prospective study was performed. During the first week, radiologists dictated all studies using prepopulated standard reports. During the second week, all studies were dictated after prepopulated reports had been disabled. Final radiology reports were evaluated for 11 different types of errors. Each error within a report was classified individually. The median time required to dictate an exam was compared between the 2 weeks. There were 12,387 reports dictated during the study, of which, 1,173 randomly distributed reports were analyzed for errors. There was no difference in the number of errors per report between the 2 weeks; however, radiologists overwhelmingly preferred using a standard report both weeks. Grammatical errors were by far the most common error type, followed by missense errors and errors of omission. There was no significant difference in the median dictation time when comparing studies performed each week. The use of prepopulated reports does not alone affect the error rate or dictation time of radiology reports. While it is a useful feature for radiologists, it must be coupled with other strategies in order to decrease errors.

  15. Radiological risk assessment of a radioactively contaminated site

    International Nuclear Information System (INIS)

    Devgun, J.S.

    1990-01-01

    A limited-scope preliminary assessment of radiological risk has been conducted at a radioactively contaminated site under current site use conditions and based on the available preliminary radiological characterization data for the site. The assessment provides useful input to the remedial action planning for the site. 8 refs., 1 fig., 2 tabs

  16. Failure mode analysis of preliminary design of ITER divertor impurity monitor

    International Nuclear Information System (INIS)

    Kitazawa, Sin-iti; Ogawa, Hiroaki

    2016-01-01

    Highlights: • Divertor impurity influx monitor for ITER (DIM) is procured by JADA. • DIM is designed to observe light from nuclear fusion plasma directly. • DIM is under preliminary design phase. • Failure mode of DIM was prepared for RAMI analysis. • RAMI analysis on DIM was performed to reduce technical risks. - Abstract: The objective of the divertor impurity influx monitor (DIM) for ITER is to measure the parameters of impurities and hydrogen isotopes (tritium, deuterium, and hydrogen) in divertor plasma using visible and UV spectroscopic techniques in the 200–1000 nm wavelength range. In ITER, special provisions are required to ensure accuracy and full functionality of the diagnostic components under harsh conditions (high temperature, high magnetic field, high vacuum condition, and high radiation field). Japan Domestic Agency is preparing the preliminary design of the ITER DIM system, which will be installed in the upper, equatorial and lower ports. The optical and mechanical designs of the DIM are conducted to fit ITER’s requirements. The optical and mechanical designs meet the requirements of spatial resolution. Some auxiliary systems were examined via prototyping. The preliminary design of the ITER DIM system was evaluated by RAMI analysis. The availability of the designed system is adequately high to satisfy the project requirements. However, some equipment does not have certain designs, and this may cause potential technical risks. The preliminary design should be modified to reduce technical risks and to prepare the final design.

  17. Summary of the Preliminary Analysis of Savannah River Depleted Uranium Trioxide

    International Nuclear Information System (INIS)

    2010-01-01

    This report summarizes a preliminary special analysis of the Savannah River Depleted Uranium Trioxide waste stream (SVRSURANIUM03, Revision 2). The analysis is considered preliminary because a final waste profile has not been submitted for review. The special analysis is performed to determine the acceptability of the waste stream for shallow land burial at the Area 5 Radioactive Waste Management Site (RWMS) at the Nevada National Security Site (NNSS). The Savannah River Depleted Uranium Trioxide waste stream requires a special analysis because the waste stream's sum of fractions exceeds one. The 99Tc activity concentration is 98 percent of the NNSS Waste Acceptance Criteria and the largest single contributor to the sum of fractions.

  18. Bibliometric analysis of the Spanish MR radiological production (2001-2007)

    International Nuclear Information System (INIS)

    Miguel-Dasit, Alberto; Marti-Bonmati, Luis; Sanfeliu, Pilar

    2008-01-01

    Objective: To evaluate the number and characteristics of papers on MR imaging written by radiologists in Spain and published in 2001-2007 Medline-indexed journals, including a comparison with the MR research output from German radiological departments. Materials and methods: Specific search profiles were devised to retrieve items from the Medline database. Relationship with the topic and major thematic areas of the articles, publication year, journal, language of publication, and mean impact factors were analyzed. Spanish and the German institutions with the highest MR productivity were identified. Also, the number of articles from Spain and Germany published in their respective official journals (Radiologia and ROFO) was recorded. Results: There were 332 Spanish articles published in 101 different journals. The higher number of papers was published in Spanish radiology and non-radiology journals (n = 105, 32%, mean IF: 0.191). The journal with the higher number of articles was Radiologia (n = 51, 15%). 'Neuroradiology' was the most frequent topic (n = 139, 42%). The Spanish productivity on MR imaging was yearly stable (p = 0.67), with the higher percentage of papers (17%) published in 2006. The topic with the higher IF was 'neuroradiology' (IF: 2.317). There were no yearly variations for the three major thematic areas ('Neuro imaging': p = 0.64; 'Body imaging': p = 0.91; and 'Non-clinical miscellanea': p = 0.46). The highest number of MR publications was found in two Spanish institutions (Dr. Peset University Hospital and Vall d'Hebron Hospital) (both, n = 28, 8%). In comparison, there were 1681 articles on MR imaging from Germany, having the two most productive institutions more than 150 papers in this period (University Hospital Essen and Eberhard-Karls University of Tuebingen). The adjusted number of articles per million populations was 20.4 for Germany and 8.1 for Spain. A total of 395 (23%) articles originating from Germany were published in the official

  19. Bioelectrical impedance analysis for bovine milk: Preliminary results

    Science.gov (United States)

    Bertemes-Filho, P.; Valicheski, R.; Pereira, R. M.; Paterno, A. S.

    2010-04-01

    This work reports the investigation and analysis of bovine milk quality by using biological impedance measurements using electrical impedance spectroscopy (EIS). The samples were distinguished by a first chemical analysis using Fourier transform midinfrared spectroscopy (FTIR) and flow citometry. A set of milk samples (100ml each) obtained from 17 different cows in lactation with and without mastitis were analyzed with the proposed technique using EIS. The samples were adulterated by adding distilled water and hydrogen peroxide in a controlled manner. FTIR spectroscopy and flow cytometry were performed, and impedance measurements were made in a frequency range from 500Hz up to 1MHz with an implemented EIS system. The system's phase shift was compensated by measuring saline solutions. It was possible to show that the results obtained with the Bioelectrical Impedance Analysis (BIA) technique may detect changes in the milk caused by mastitis and the presence of water and hydrogen peroxide in the bovine milk.

  20. Radiological assessment and optimization

    International Nuclear Information System (INIS)

    Zeevaert, T.; Sohier, A.

    1998-01-01

    The objectives of SCK-CEN's research in the field of radiological assessment and optimization are (1) to implement ALARA principles in activities with radiological consequences; (2) to develop methodologies for radiological optimization in decision-aiding; (3) to improve methods to assess in real time the radiological hazards in the environment in case of an accident; (4) to develop methods and programmes to assist decision-makers during a nuclear emergency; (5) to support the policy of radioactive waste management authorities in the field of radiation protection; (6) to investigate computer codes in the area of multi criteria analysis; (7) to organise courses on off-site emergency response to nuclear accidents. Main achievements in these areas for 1997 are summarised

  1. Radiological pathways analysis for spent solvents from the boiler chemical cleaning at the Pickering Nuclear Site

    International Nuclear Information System (INIS)

    Garisto, N.C.; Eslami, Z.; Hodgins, S.; Beaman, T.; Von Svoboda, S.; Marczak, J.

    2006-01-01

    Spent solvents are generated as a result of Boiler Chemical Cleanings (BCC) at CANDU reactor sites. These solutions contain small amount of radioactivity from a number of different sources including: Cut tubes - short sections of boiler tubes are infrequently removed from the boilers for a detailed characterization. These tubes are typically only plugged at the tubesheet allowing the primary side deposits to be exposed to BCC solvents. Tube leaks - primary to secondary side leaks also occur infrequently as a result of tube degradation. Radioactivity from the leaking fluid can consequently be deposited in the sludge on the secondary side of the tubes. Diffusion of tritium - during normal operation of the reactor units, tritium slowly diffuses from the heavy water in the primary heat-transfer system to the light-water coolant on the secondary side. Some of this tritium is retained in the secondary side deposits. The Pickering Nuclear Generating Station (PNGS) would like the flexibility to have several options for handling the spent solvent waste and associated rinse water from BCC. To this end, a radiological pathways analysis was undertaken to determine dose consequences associated with each option. Sample results from this study are included in this paper. The pathways analysis is used in this study to calculate dose to hypothetical receptors including individuals such as truck drivers, incinerator workers, residue (ash) handlers, residents who live near the landfill, inadvertent intruders into the landfill after closure and residents who live near the outfall. This dose is compared to a de minimis dose. A de minimis dose or dose rate represents a level of risk, which is generally accepted as being of no significance. Shipments of spent solvents and rinse water with corresponding doses below de minimis can be sent to conventional (i.e., non-radioactive) landfills for incineration and disposal as the radioactive dose associated with them is much less than natural

  2. Clinical and radiological evolution of Intervened patients of total arthroplasty of hip with prostheses of resuperficialization metal-metal - Preliminary report

    International Nuclear Information System (INIS)

    Galvan Villamarin, Fernando; Bernal Torres, Fabio A; Paez, Jose Mauricio and others

    2006-01-01

    The articular degeneration of the hip in young patients requires including therapeutical alternatives for the management of this population. The resurfacing prostheses with metal-metal surfaces is an alternative for this type of patients. Reports with short and medium follow up are very promising, besides the different studies of laboratory that bear, the theoretical bases for their success. In this descriptive study, observational cases series type is described the radiological and clinical evolution of patients intervened of total arthroplasty of hip with resurfacing prostheses metal-metal in the hospital el Tunal of Bogota. The results of 31 hips are presented (27 patients) with an age average of 50 years old and a medium follow up of 16 months, with a good post surgical functional result with a median of 96 in the Harris Scores. The complications presented in the patient series are described and their relation with the different factors analyzed

  3. Isolation and preliminary function analysis of a Na + /H + antiporter ...

    African Journals Online (AJOL)

    A full-length cDNA Na+/H+ antiporter gene (MzNHX1) was isolated from Malus zumi according to the homologous Na+/H+ antiporter gene region in plants. Sequence analysis indicated that the cDNA was 2062 bp in length, including an open reading frame (ORF) of 1629 bp, which encoded a predicted polypeptide of 542 ...

  4. A Preliminary Analysis of a Behavioral Classrooms Needs Assessment

    Science.gov (United States)

    Leaf, Justin B.; Leaf, Ronald; McCray, Cynthia; Lamkins, Carol; Taubman, Mitchell; McEachin, John; Cihon, Joseph H.

    2016-01-01

    Today many special education classrooms implement procedures based upon the principles of Applied Behavior Analysis (ABA) to establish educationally relevant skills and decrease aberrant behaviors. However, it is difficult for school staff and consultants to evaluate the implementation of various components of ABA and general classroom set up. In…

  5. Preliminary analysis of a 1:4 scale prestressed concrete containment vessel model

    International Nuclear Information System (INIS)

    Dameron, R.A.; Rashid, Y.R.; Luk, V.K.; Hessheimer, M.F.

    1997-01-01

    Sandia National Laboratories is conducting a research program to investigate the integrity of nuclear containment structures. As part of the program Sandia will construct an instrumented 1:4 scale model of a prestressed concrete containment vessel (PCCV) for pressurized water reactors (PWR), which will be pressure tested up to its ultimate capacity. One of the key program objectives is to develop validated methods to predict the structural performance of containment vessels when subjected to beyond design basis loadings. Analytical prediction of structural performance requires a stepwise, systematic approach that addresses all potential failure modes. The analysis effort includes two and three-dimensional nonlinear finite element analyses of the PCCV test model to evaluate its structural performance under very high internal pressurization. Such analyses have been performed using the nonlinear concrete constitutive model, ANACAP-U, in conjunction with the ABAQUS general purpose finite element code. The analysis effort is carried out in three phases: preliminary analysis; pretest prediction; and post-test data interpretation and analysis evaluation. The preliminary analysis phase serves to provide instrumentation support and identify candidate failure modes. The associated tasks include the preliminary prediction of failure pressure and probable failure locations and the development of models to be used in the detailed failure analyses. This paper describes the modeling approaches and some of the results obtained in the first phase of the analysis effort

  6. Pilot Workload and Speech Analysis: A Preliminary Investigation

    Science.gov (United States)

    Bittner, Rachel M.; Begault, Durand R.; Christopher, Bonny R.

    2013-01-01

    Prior research has questioned the effectiveness of speech analysis to measure the stress, workload, truthfulness, or emotional state of a talker. The question remains regarding the utility of speech analysis for restricted vocabularies such as those used in aviation communications. A part-task experiment was conducted in which participants performed Air Traffic Control read-backs in different workload environments. Participant's subjective workload and the speech qualities of fundamental frequency (F0) and articulation rate were evaluated. A significant increase in subjective workload rating was found for high workload segments. F0 was found to be significantly higher during high workload while articulation rates were found to be significantly slower. No correlation was found to exist between subjective workload and F0 or articulation rate.

  7. MEMO radiology

    International Nuclear Information System (INIS)

    Wagner-Manslau, C.

    1989-01-01

    This radiology volume is a concise handbook of imaging techniques, nuclear medicine, and radiation therapy, albeit that the main emphasis is on classic radiology. It offers, for instance, a survey of radiological findings for the most frequent pathological conditions, many overviews of differential diagnosis, a glossary of the technical bases of radiology and so forth. The contents are divided into the following chapters: Physical and biological bases; skeleton; thorax with the subdivisions lungs, heart, mediastinum, and pleura; gastrointestinal tract with the subsections esophagus, small and large intestine; liver; biliary tract; pancreas; retroperitoneal space; kidney; suprarenal glands; bladder; blood vessels, lymph nodes, spleen; mammary glands; female genitals; prostate and scrotum, epididymis and seminal vesicle. (orig./MG) With 23 figs [de

  8. Preliminary analysis of productivity of fruiting fungi on Strzeleckie meadows

    Directory of Open Access Journals (Sweden)

    Barbara Sadowska

    2014-11-01

    Full Text Available Analysis demonstrated that the fresh ahd dry weight as well as the ash content of fungal fruit bodies collected on a forest-surrounded unmown meadow (Stellario-Deschampsietum Freitag 1957 and Caricetum elatae W.Koch 1926 were lower than the same values for a plot of exploited mown meadow and higher than on an exploited unmown meadow (Arrhenatheretum medioeuropaeum (Br.-Bl. Oberd. 1952.

  9. Preliminary analysis on incore performance of nuclear fuel: pt. 4

    International Nuclear Information System (INIS)

    Noh, S.K.; Chang, M.H.; Lee, C.C.; Chung, Y.H.; Kuk, K.Y.; Park, C.Y.; Lee, S.K.

    1981-01-01

    An analysis has been performed for thermal hydraulic design parameters of Wolsung-1 reactor core in steady state with the help of a computer code COBRA-IV-I. The design parameters are coolant enthalpy, flow velocity, coolant quality, pressure and fuel temperature distribution. The maximum power channel has been taken into account in this work. The results appear to be reasonably agreeable with data from PSR'S, with the maximum difference between this work and PSR'S being 4.3%

  10. Job Search Success in Local Labour Markets - A Preliminary Analysis

    OpenAIRE

    Greig, Malcolm; McQuaid, Ronald W.

    2001-01-01

    This study tests the appropriateness of current government employment policies, in particular the New Deal, in targeting specific groups of unemployed jobseekers. A sample of 169 unemployed jobseekers is divided into those who were successful and unsuccessful in finding employment and each group is analysed in terms of their attributes. A factor analysis of these attributes is then carried out in order to develop typical profiles of unsuccessful jobseekers who are possibly in need of special ...

  11. Preliminary analysis of knee stress in Full Extension Landing

    Directory of Open Access Journals (Sweden)

    Majid Davoodi Makinejad

    2013-09-01

    Full Text Available OBJECTIVE: This study provides an experimental and finite element analysis of knee-joint structure during extended-knee landing based on the extracted impact force, and it numerically identifies the contact pressure, stress distribution and possibility of bone-to-bone contact when a subject lands from a safe height. METHODS: The impact time and loads were measured via inverse dynamic analysis of free landing without knee flexion from three different heights (25, 50 and 75 cm, using five subjects with an average body mass index of 18.8. Three-dimensional data were developed from computed tomography scans and were reprocessed with modeling software before being imported and analyzed by finite element analysis software. The whole leg was considered to be a fixed middle-hinged structure, while impact loads were applied to the femur in an upward direction. RESULTS: Straight landing exerted an enormous amount of pressure on the knee joint as a result of the body's inability to utilize the lower extremity muscles, thereby maximizing the threat of injury when the load exceeds the height-safety threshold. CONCLUSIONS: The researchers conclude that extended-knee landing results in serious deformation of the meniscus and cartilage and increases the risk of bone-to-bone contact and serious knee injury when the load exceeds the threshold safety height. This risk is considerably greater than the risk of injury associated with walking downhill or flexion landing activities.

  12. Radiological hazards

    International Nuclear Information System (INIS)

    Hamilton, M.

    1984-01-01

    The work of the (United Kingdom) National Radiological Protection Board is discussed. The following topics are mentioned: relative contributions to genetically significant doses of radiation from various sources; radon gas in non-coal mines and in dwelling houses; effects of radiation accidents; radioactive waste disposal; radiological protection of the patient in medicine; microwaves, infrared radiation and cataracts; guidance notes for use with forthcoming Ionising Radiations Regulations; training courses; personal dosimetry service; work related to European Communities. (U.K.)

  13. Analysis for preliminary evaluation of discrete fracture flow and large-scale permeability in sedimentary rocks

    International Nuclear Information System (INIS)

    Kanehiro, B.Y.; Lai, C.H.; Stow, S.H.

    1987-05-01

    Conceptual models for sedimentary rock settings that could be used in future evaluation and suitability studies are being examined through the DOE Repository Technology Program. One area of concern for the hydrologic aspects of these models is discrete fracture flow analysis as related to the estimation of the size of the representative elementary volume, evaluation of the appropriateness of continuum assumptions and estimation of the large-scale permeabilities of sedimentary rocks. A basis for preliminary analysis of flow in fracture systems of the types that might be expected to occur in low permeability sedimentary rocks is presented. The approach used involves numerical modeling of discrete fracture flow for the configuration of a large-scale hydrologic field test directed at estimation of the size of the representative elementary volume and large-scale permeability. Analysis of fracture data on the basis of this configuration is expected to provide a preliminary indication of the scale at which continuum assumptions can be made

  14. Preliminary RAMI analysis of DFLL TBS for ITER

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Dagui [Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui, 230031 (China); University of Science and Technology of China, Hefei, Anhui, 230031 (China); Yuan, Run [Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui, 230031 (China); Wang, Jiaqun, E-mail: jiaqun.wang@fds.org.cn [Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui, 230031 (China); Wang, Fang; Wang, Jin [Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui, 230031 (China)

    2016-11-15

    Highlights: • We performed the functional analysis of the DFLL TBS. • We performed a failure mode analysis of the DFLL TBS. • We estimated the reliability and availability of the DFLL TBS. • The ITER RAMI approach was applied to the DFLL TBS for technical risk control in the design phase. - Abstract: ITER is the first fusion machine fully designed to prove the physics and technological basis for next fusion power plants. Among the main technical objectives of ITER is to test and validate design concepts of tritium breeding blankets relevant to the fusion power plants. To achieve this goal, China has proposed the dual functional lithium-lead test blanket module (DFLL TBM) concept design. The DFLL TBM and its associated ancillary system were called DFLL TBS. The DFLL TBS play a key role in next fusion reactor. In order to ensure reliable and available of DFLL TBS, the risk control project of DFLL TBS has been put on the schedule. As the stage of the ITER technical risk control policy, the RAMI (Reliability, Availability, Maintainability, Inspectability) approach was used to control the technical risk of ITER. In this paper, the RAMI approach was performed on the conceptual design of DFLL TBS. A functional breakdown was prepared on DFLL TBS, and the system was divided into 3 main functions and 72 basic functions. Based on the result of functional breakdown of DFLL TBS, the reliability block diagrams were prepared to estimate the reliability and availability of each function under the stipulated operating conditions. The inherent availability of the DFLL TBS expected after implementation of mitigation actions was calculated to be 98.57% over 2 years based on the ITER reliability database. A Failure Modes Effects and Criticality Analysis (FMECA) was performed with criticality charts highlighting the risk level of the different failure modes with regard to their probability of occurrence and their effects on the availability.

  15. Preliminary safety analysis for key design features of KALIMER

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, D. H.; Kwon, Y. M.; Chang, W. P.; Suk, S. D.; Lee, S. O.; Lee, Y. B.; Jeong, K. S

    2000-07-01

    KAERI is currently developing the conceptual design of a liquid metal reactor, KALIMER(Korea Advanced Liquid Metal Reactor) under the long-term nuclear R and D program. In this report, descriptions of the KALIMER safety design features and safety analyses results for selected ATWS accidents are presented. First, the basic approach to achieve the safety goal is introduced in chapter 1, and the safety evaluation procedure for the KALIMER design is described in chapter 2. It includes event selection, event categorization, description of design basis events, and beyond design basis events. In chapter 3, results of inherent safety evaluations for the KALIMER conceptual design are presented. The KALIMER core and plant system are designed to assure design performance during a selected set of events without either reactor control or protection system intervention. Safety analyses for the postulated anticipated transient without scram(ATWS) have been performed to investigate the KALIMER system response to the events. They are categorized as bounding events(BEs) because of their low probability of occurrence. In chapter 4, the design of the KALIMER containment dome and the results of its performance analysis are presented. The designs of the existing LMR containment and the KALIMER containment dome have been compared in this chapter. Procedure of the containment performance analysis and the analysis results are described along with the accident scenario and source terms. Finally, a simple methodology is introduced to investigate the core kinetics and hydraulic behavior during HCDA in chapter 5. Mathematical formulations have been developed in the framework of the modified bethe-tait method, and scoping analyses have been performed for the KALIMER core behavior during super-prompt critical excursions.

  16. Computer content analysis of schizophrenic speech: a preliminary report.

    Science.gov (United States)

    Tucker, G J; Rosenberg, S D

    1975-06-01

    Computer analysis significantly differtiated the thermatic content of the free speech of 10 schizophrenic patients from that of 10 nonschizophrenic patients and from the content of transcripts of dream material from 10 normal subjects. Schizophrenic patients used the thematic categories in factor 1 (the "schizophrenic factor") 3 times more frequently than the nonschizophrenics and 10 times more frequently than the normal subjects (p smaller than 01). In general, the language content of the schizophrenic patient mirrored an almost agitated attempt to locate oneself in time and space and to defend against internal discomfort and confusion. The authors discuss the implications of this study for future research.

  17. Preliminary report on the PIXE analysis of the squid statoliths

    International Nuclear Information System (INIS)

    Ikeda, Yuzuru; Arai, Nobuaki; Sakamoto, Wataru; Murayama, Tatsuro; Maeda, Kuniko; Yoshida, Koji.

    1996-01-01

    Micro trace elements in the squid statolith, a calcareous stone which acts as a balancer and hearing, was analyzed with Particle Induced X-ray Emission (PIXE) for the Japanese common squid for the first time. Calcium is the main component of the squid statoliths, which means that squid statolith is the pure calcified structure similar to the fish otolith. Beside Ca, Sr was detected with strong dosage, and some other elements as Mn, Fe, Cu, Zn and As were also detected. Possible assumption of intake of microelements to the statoliths and the suitability of PIXE for statoliths analysis are discussed. (author)

  18. Macroalgae as a Biomass Feedstock: A Preliminary Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Roesijadi, Guritno; Jones, Susanne B.; Snowden-Swan, Lesley J.; Zhu, Yunhua

    2010-09-26

    A thorough of macroalgae analysis as a biofuels feedstock is warranted due to the size of this biomass resource and the need to consider all potential sources of feedstock to meet current biomass production goals. Understanding how to harness this untapped biomass resource will require additional research and development. A detailed assessment of environmental resources, cultivation and harvesting technology, conversion to fuels, connectivity with existing energy supply chains, and the associated economic and life cycle analyses will facilitate evaluation of this potentially important biomass resource.

  19. Preliminary safety analysis report for the Waste Characterization Facility

    International Nuclear Information System (INIS)

    1994-10-01

    This safety analysis report outlines the safety concerns associated with the Waste Characterization Facility located in the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. The three main objectives of the report are to: define and document a safety basis for the Waste Characterization Facility activities; demonstrate how the activities will be carried out to adequately protect the workers, public, and environment; and provide a basis for review and acceptance of the identified risk that the managers, operators, and owners will assume. 142 refs., 38 figs., 39 tabs

  20. Analysis of Influencing Factors Related to Health Promotion Behavior in Hospital Radiological Technologists

    International Nuclear Information System (INIS)

    Ko, Jong Kyung; Kwon, Duk Mun; Kang, Yeong Han

    2009-01-01

    The purpose of this study was to analyze factors that could affect health of radiological technologists, which is useful for health care and development of programs for health promotion. Subjects were 234 of radiological technologists who work in general hospitals. Some questionnaires were made about perceptions of health condition and promotional behavior of health for this study. The questionnaires of health perception were 20 items that consist of the present condition of health, health concern and sensitivity. The reliability was sufficient(Cronbach's α=0.79). The other questionnaires about health promotion behavior were 47 items that consist of self-realization, health responsibility, exercise, nutrition, personal relationships, and stress management. The results turned out to be was sufficient (Cronbach's α=0.93). Every data was treated statistically, comparison of average(t-test, ANOVA), correlation, and multiple regression. Related factors to health promotion behavior were age, marriage, salary, class of one's position, career, employment, and religion, in general features. In health life habit, related factors were smoke and exercise. Results of health promotion behavior was 2.90 of mean score, 0.37 of standard deviation. Correlations between factors of health perception and health promotion behavior was positive(p<0.01). Health promotion behavior were affected by sensitivity, presents condition of health, exercise, smoke, career. Sensitivity was the most affectable variable, which means that promotional behavior score became higher and higher as the score of sensitivity and present condition were increased. In addition, persons who exercise regularly, had been smoked, and has higher career showed higher score of promotional behavior. Radiological technologists have to keep their health, trying not to infected by a disease. Most of all, no smoking and regular exercise are the most important thing to all of members.

  1. Cost and Morbidity Analysis of Chest Port Insertion: Interventional Radiology Suite Versus Operating Room.

    Science.gov (United States)

    LaRoy, Jennifer R; White, Sarah B; Jayakrishnan, Thejus; Dybul, Stephanie; Ungerer, Dirk; Turaga, Kiran; Patel, Parag J

    2015-06-01

    To compare complications and cost, from a hospital perspective, of chest port insertions performed in an interventional radiology (IR) suite versus in surgery in an operating room (OR). This study was approved by an institutional review board and is HIPAA compliant. Medical records were retrospectively searched on consecutive chest port placement procedures, in the IR suite and the OR, between October 22, 2010 and February 26, 2013, to determine patients' demographic information and chest port-related complications and/or infections. A total of 478 charts were reviewed (age range: 21-85 years; 309 women, 169 men). Univariate and bivariate analyses were performed to identify risk factors associated with an increased complication rate. Cost data on 149 consecutive Medicare outpatients (100 treated in the IR suite; 49 treated in the OR) who had isolated chest port insertions between March 2012 and February 2013 were obtained for both the operative services and pharmacy. Nonparametric tests for heterogeneity were performed using the Kruskal-Wallis method. Early complications occurred in 9.2% (22 of 239) of the IR patients versus 13.4% (32 of 239) of the OR patients. Of the 478 implanted chest ports, 9 placed in IR and 18 placed in surgery required early removal. Infections from the ports placed in IR versus the OR were 0.25 versus 0.18 infections per 1000 catheters, respectively. Overall mean costs for chest port insertion were significantly higher in the OR, for both room and pharmacy costs (P chest ports in an OR setting was almost twice that of placement in the IR suite. Hospital costs to place a chest port were significantly lower in the IR suite than in the OR, whereas radiology and surgery patients did not show a significantly different rate of complications and/or infections. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  2. Analysis of Influencing Factors Related to Health Promotion Behavior in Hospital Radiological Technologists

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Jong Kyung [Kim, In Hwan Internal Medicine Health Promotion Cnter, Youngcheon (Korea, Republic of); Kwon, Duk Mun [Dept. of Radiology Technology, Daegu Health College, Daegu (Korea, Republic of); Kang, Yeong Han [Dept. of Diagnostic Radiology, Daegu Catholic Univesity Hospital, Daegu (Korea, Republic of)

    2009-12-15

    The purpose of this study was to analyze factors that could affect health of radiological technologists, which is useful for health care and development of programs for health promotion. Subjects were 234 of radiological technologists who work in general hospitals. Some questionnaires were made about perceptions of health condition and promotional behavior of health for this study. The questionnaires of health perception were 20 items that consist of the present condition of health, health concern and sensitivity. The reliability was sufficient(Cronbach's {alpha}=0.79). The other questionnaires about health promotion behavior were 47 items that consist of self-realization, health responsibility, exercise, nutrition, personal relationships, and stress management. The results turned out to be was sufficient (Cronbach's {alpha}=0.93). Every data was treated statistically, comparison of average(t-test, ANOVA), correlation, and multiple regression. Related factors to health promotion behavior were age, marriage, salary, class of one's position, career, employment, and religion, in general features. In health life habit, related factors were smoke and exercise. Results of health promotion behavior was 2.90 of mean score, 0.37 of standard deviation. Correlations between factors of health perception and health promotion behavior was positive(p<0.01). Health promotion behavior were affected by sensitivity, presents condition of health, exercise, smoke, career. Sensitivity was the most affectable variable, which means that promotional behavior score became higher and higher as the score of sensitivity and present condition were increased. In addition, persons who exercise regularly, had been smoked, and has higher career showed higher score of promotional behavior. Radiological technologists have to keep their health, trying not to infected by a disease. Most of all, no smoking and regular exercise are the most important thing to all of members.

  3. Preliminary uranium enrichment analysis results using cadmium zinc telluride detectors

    International Nuclear Information System (INIS)

    Lavietes, A.D.; McQuaid, J.H.; Paulus, T.J.

    1995-01-01

    Lawrence Livermore National Laboratory (LLNL) and EG ampersand G ORTEC have jointly developed a portable ambient-temperature detection system that can be used in a number of application scenarios. The detection system uses a planar cadmium zinc telluride (CZT) detector with custom-designed detector support electronics developed at LLNL and is based on the recently released MicroNOMAD multichannel analyzer (MCA) produced by ORTEC. Spectral analysis is performed using software developed at LLNL that was originally designed for use with high-purity germanium (HPGe) detector systems. In one application, the CZT detection system determines uranium enrichments ranging from less than 3% to over 75% to within accuracies of 20%. The analysis was performed using sample sizes of 200 g or larger and acquisition times of 30 min. The authors have demonstrated the capabilities of this system by analyzing the spectra gathered by the CZT detection system from uranium sources of several enrichments. These experiments demonstrate that current CZT detectors can, in some cases, approach performance criteria that were previously the exclusive domain of larger HPGe detector systems

  4. Analysis of dose to crystalline in Interventional radiology: a purpose of one case

    International Nuclear Information System (INIS)

    Carrera M, F.; Moreno R, F.; Velazquez M, F.; Manzano M, F.J.; Moreno S, T.

    1998-01-01

    The present work shows the dose values to crystalline for the personnel which works in interventional radiology procedures. It was took data of 436 studies with a total of 2,133.4 minutes in fluoroscopy and 19,563 images. It was showed dose values to crystalline in three situations: without blinding, with blinding of 0.25 and 0.50 mm Pb and by type of study: fluoroscopy, graphie and total. The dose means and ranges to patient for each of these studies also are detailed. (Author)

  5. A new code for spectrometric analysis for environmental radiological surveillance on monitors focused on gamma radioactivity on aerosols

    Energy Technology Data Exchange (ETDEWEB)

    De Blas, Alfredo; Tapia, Carlos; Riego, Albert; Garcia, Roger; Dies, Javier; Diaz, Pedro [Nuclear Engineering Research Group, Departament of Physics and Nuclear Engineering, Technical University of Catalonia, Barcelona (Spain); Toral, Juan [Raditel Serveis, Tarragona (Spain); Batalla, Enric [Radiological Activities Corrdination Service - SCAR, Generalitat de Catalunya. Barcelona (Spain)

    2015-07-01

    pGamma is a code developed by the NERG group of the Technical University of Catalonia - Barcelona Tech for the analysis of gamma spectra generated by the Equipment for the Continuous Measurement and Identification of Gamma Radioactivity on Aerosols with Paper Filter developed for our group and Raditel Servies company. Nowadays the code is in the process of adaptation for the monitors of the Environmental Radiological Surveillance Network of the Local Government of Catalonia (Generalitat of Catalonia), Spain. The code is a Spectrum Analysis System, it identifies the gamma emitters on the spectrum, determines its Concentration of Activity, generates alarms depending on the Activity of the emitters and generates a report. The Spectrum Analysis System includes a library with emitters of interest, NORM and artificial. The code is being used on the three stations with the aerosol monitor of the Network (Asco and Vandellos, near both Nuclear Power Plants and Barcelona). (authors)

  6. Importance of Radiology among the Spanish medical journal dealing with radiodiagnostics: analysis of their production between 1984 and 1993

    International Nuclear Information System (INIS)

    Martinez, M.; Saez, J.M.; Garcia-Medina, V.

    1997-01-01

    We present a bibliometric analysis of the publications of the journal Radiologia between 1984 and 1993 to contribute to the study of radiodiagnostics reporting in Spain and to determine the importance of Radiologia as a source of information on this subject. We have used the database of the Spanish Medical Index (Indice Medico Espanol, IME) and the journal itself, analyzing the volume, course and distribution of publications on radiodiagnostic procedures. The journal Radiologia publishes 20.1% of the articles dealing with radiology and radiation therapy in Spain. The total number of works was 1,344, that of authors was 2,580 and that of signatures was 6.173, presenting an exponential growth with doubling times of 83.3, 8.5 and 7.4 years, respectively. The analysis shows that the journal's production not only increases over time, but also increments the proportion it contributes to the Spanish medical press as a whole. Radiologia is the most representative journal, in terms of volume of the scientific activity reported in the field of radiodiagnostics in Spain, and its production tends to adapt to the model established for other firmly consolidated scientific and medical disciplines. It alone constitutes the core of the medical journals devoted to radiology and its mean index of circulation according to the IME is 85.79/%. (Author) 34 refs

  7. A study on the relationship between radiologic classification and glycosaminoglycan analysis of cystic fluids in oral region

    International Nuclear Information System (INIS)

    Park, In Woo; You, Dong Soo

    1993-01-01

    This study was designed to evaluate the correlationship between radiologic classifications of cysts in oral region and glycosaminoglycan analysis of cystic fluids using cellulose acetate electrophoresis. The materials for this study consisted of 37 cases-8 periapical cysts, 10 dentigerous cysts, 10 primordial cysts, 2 residual cyst, 3 incisive canal cysts, 2 post-operative maxillary cysts, 1 mucocele on maxillary sinus, and 1 unicystic ameloblastoma-diagnosed as cystic lesions radiologically. The obtained results were as follows: 1. At the stepwise discriminant analysis, four variables-low mobility material, hiparin, hyaluronic acid, and dermatan sulfate- were used to define diagnostic model for the odontogenic cyst. The model produced a seventeenths of 100% and a specificity of 85%. 2. The intensities of heparin and chondroitin-4-sulfate were greater in dentigerous cyst than periapical cyst (p<0.05). 3. It showed no statistically significant difference in glycosaminoglycan of the cystic fluids between dentigerous cyst and primordial cyst (p<0.05). 4. On the fluids of the cysts originated from maxillary sinus, there were especially high intensities of heparin and dermatan sulfate, and low intensity of chondroitin-4-sulfate. 5. On the fluids of unicystic ameloblastoma, there were high intensity of dermatan sulfate and low intensity of chondroitin-4-sulfate.

  8. A study on the relationship between radiologic classification and glycosaminoglycan analysis of cystic fluids in oral region

    Energy Technology Data Exchange (ETDEWEB)

    Park, In Woo; You, Dong Soo [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1993-08-15

    This study was designed to evaluate the correlationship between radiologic classifications of cysts in oral region and glycosaminoglycan analysis of cystic fluids using cellulose acetate electrophoresis. The materials for this study consisted of 37 cases-8 periapical cysts, 10 dentigerous cysts, 10 primordial cysts, 2 residual cyst, 3 incisive canal cysts, 2 post-operative maxillary cysts, 1 mucocele on maxillary sinus, and 1 unicystic ameloblastoma-diagnosed as cystic lesions radiologically. The obtained results were as follows: 1. At the stepwise discriminant analysis, four variables-low mobility material, hiparin, hyaluronic acid, and dermatan sulfate- were used to define diagnostic model for the odontogenic cyst. The model produced a seventeenths of 100% and a specificity of 85%. 2. The intensities of heparin and chondroitin-4-sulfate were greater in dentigerous cyst than periapical cyst (p<0.05). 3. It showed no statistically significant difference in glycosaminoglycan of the cystic fluids between dentigerous cyst and primordial cyst (p<0.05). 4. On the fluids of the cysts originated from maxillary sinus, there were especially high intensities of heparin and dermatan sulfate, and low intensity of chondroitin-4-sulfate. 5. On the fluids of unicystic ameloblastoma, there were high intensity of dermatan sulfate and low intensity of chondroitin-4-sulfate.

  9. Yucca Mountain transportation routes: Preliminary characterization and risk analysis

    International Nuclear Information System (INIS)

    Souleyrette, R.R. II; Sathisan, S.K.; di Bartolo, R.

    1991-01-01

    In this study, rail and highway routes which may be used for shipments of high-level nuclear waste to a proposed repository at Yucca Mountain, Nevada are characterized. This characterization facilitates three types of impact analysis: comparative study, limited worst-case assessment, and more sophisticated probabilistic risk assessment techniques. Data for relative and absolute impact measures are provided to support comparisons of routes based on selected characteristics. A worst-case scenario assessment is included to determine potentially critical and most likely places for accidents or incidents to occur. The assessment facilitated by the data in this study is limited because impact measures are restricted to the identification of potential areas or persons affected. No attempt is made to quantify the magnitude of these impacts. Most likely locations for accidents to occur are determined relative to other locations within the scope of this study. Independent factors and historical trends used to identify these likely locations are only proxies for accident probability

  10. City of Hoboken Energy Surety Analysis: Preliminary Design Summary

    Energy Technology Data Exchange (ETDEWEB)

    Stamp, Jason Edwin [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Military and Energy Systems Analysis Dept.; Baca, Michael J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Military and Energy Systems Analysis Dept.; Munoz-Ramos, Karina [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Military and Energy Systems Analysis Dept.; Schenkman, Benjamin L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Military and Energy Systems Analysis Dept.; Eddy, John P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Systems Readiness and Sustainment Technology Dept.; Smith, Mark A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Systems Readiness and Sustainment Technology Dept.; Guttromson, Ross [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Electric Power Systems Research Dept.; Henry, Jordan M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Critical Infrastructure Systems Dept.; Jensen, Richard Pearson [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Geomechanics Dept.

    2014-09-01

    In 2012, Hurricane Sandy devastated much of the U.S. northeast coastal areas. Among those hardest hit was the small community of Hoboken, New Jersey, located on the banks of the Hudson River across from Manhattan. This report describes a city-wide electrical infrastructure design that uses microgrids and other infrastructure to ensure the city retains functionality should such an event occur in the future. The designs ensure that up to 55 critical buildings will retain power during blackout or flooded conditions and include analysis for microgrid architectures, performance parameters, system control, renewable energy integration, and financial opportunities (while grid connected). The results presented here are not binding and are subject to change based on input from the Hoboken stakeholders, the integrator selected to manage and implement the microgrid, or other subject matter experts during the detailed (final) phase of the design effort.

  11. The Σ − D relation for planetary nebulae: Preliminary analysis

    Directory of Open Access Journals (Sweden)

    Urošević D.

    2007-01-01

    Full Text Available An analysis of the relation between radio surface brightness and diameter, so-called Σ − D relation, for planetary nebulae (PNe is presented: i the theoretical Σ − D relation for the evolution of bremsstrahlung surface brightness is derived; ii contrary to the results obtained earlier for the Galactic supernova remnant (SNR samples, our results show that the updated sample of Galactic PNe does not severely suffer from volume selection effect - Malmquist bias (same as for the extragalactic SNR samples and; iii we conclude that the empirical S − D relation for PNe derived in this paper is not useful for valid determination of distances for all observed PNe with unknown distances. .

  12. A Preliminary Tsunami Vulnerability Analysis for Yenikapi Region in Istanbul

    Science.gov (United States)

    Ceren Cankaya, Zeynep; Suzen, Lutfi; Cevdet Yalciner, Ahmet; Kolat, Cagil; Aytore, Betul; Zaytsev, Andrey

    2015-04-01

    One of the main requirements during post disaster recovery operations is to maintain proper transportation and fluent communication at the disaster areas. Ports and harbors are the main transportation hubs which must work with proper performance at all times especially after the disasters. Resilience of coastal utilities after earthquakes and tsunamis have major importance for efficient and proper rescue and recovery operations soon after the disasters. Istanbul is a mega city with its various coastal utilities located at the north coast of the Sea of Marmara. At Yenikapi region of Istanbul, there are critical coastal utilities and vulnerable coastal structures and critical activities occur daily. Fishery ports, commercial ports, small craft harbors, passenger terminals of intercity maritime transportation, water front commercial and/or recreational structures are some of the examples of coastal utilization which are vulnerable against marine disasters. Therefore their vulnerability under tsunami or any other marine hazard to Yenikapi region of Istanbul is an important issue. In this study, a methodology of vulnerability analysis under tsunami attack is proposed with the applications to Yenikapi region. In the study, high resolution (1m) GIS database of Istanbul Metropolitan Municipality (IMM) is used and analyzed by using GIS implementation. The bathymetry and topography database and the vector dataset containing all buildings/structures/infrastructures in the study area are obtained for tsunami numerical modeling for the study area. GIS based tsunami vulnerability assessment is conducted by applying the Multi-criteria Decision Making Analysis (MCDA). The tsunami parameters from deterministically defined worst case scenarios are computed from the simulations using tsunami numerical model NAMI DANCE. The vulnerability parameters in the region due to two different classifications i) vulnerability of buildings/structures and ii) vulnerability of (human) evacuation

  13. Preliminary analysis of Psoroptes ovis transcriptome in different developmental stages

    Directory of Open Access Journals (Sweden)

    Man-Li He

    2016-11-01

    Full Text Available Abstract Background Psoroptic mange is a chronic, refractory, contagious and infectious disease mainly caused by the mange mite Psoroptes ovis, which can infect horses, sheep, buffaloes, rabbits, other domestic animals, deer, wild camels, foxes, minks, lemurs, alpacas, elks and other wild animals. Features of the disease include intense pruritus and dermatitis, depilation and hyperkeratosis, which ultimately result in emaciation or death caused by secondary bacterial infections. The infestation is usually transmitted by close contact between animals. Psoroptic mange is widespread in the world. In this paper, the transcriptome of P. ovis is described following sequencing and analysis of transcripts from samples of larvae (i.e. the Pso_L group and nymphs and adults (i.e. the Pso_N_A group. The study describes differentially expressed genes (DEGs and genes encoding allergens, which help understanding the biology of P. ovis and lay foundations for the development of vaccine antigens and drug target screening. Methods The transcriptome of P. ovis was assembled and analyzed using bioinformatic tools. The unigenes of P. ovis from each developmental stage and the unigenes differentially between developmental stages were compared with allergen protein sequences contained in the allergen database website to predict potential allergens. Results We identified 38,836 unigenes, whose mean length was 825 bp. On the basis of sequence similarity with seven databases, a total of 17,366 unigenes were annotated. A total of 1,316 DEGs were identified, including 496 upregulated and 820 downregulated in the Pso_L group compared with the Pso_N_A group. We predicted 205 allergens genes in the two developmental stages similar to genes from other mites and ticks, of these, 14 were among the upregulated DEGs and 26 among the downregulated DEGs. Conclusion This study provides a reference transcriptome of P. ovis in absence of a reference genome. The analysis of DEGs and

  14. Preliminary analysis of a new IAEA lichen AQCS material

    International Nuclear Information System (INIS)

    Grass, F.; Bichler, M.; Dorner, J.; Ismail, S.; Kregshammer, P.; Zamini, S.; Gwozdz, R.

    2000-01-01

    Lichen with a higher content on interesting trace elements were analyzed by activation analysis and by X-RF measurements on pressed lichen samples. The activation analyses were performed in three different ways: Short-time AA in the Fast Irradiation and Measurement System. Up to 580mg of lichen were irradiated 5-300s in polyethylene containers. Single spectra and spectra of 6 samples were summed up and evaluated. Longer irradiation at the ASTRA-Reactor: 2h at 8E13/s cm 2 . 100-150mg of lichen were irradiated in quartz suprasil vials. Longer irradiation at the Institute's TRIGA-Reactor: 6-7h at 1.8E12/s cm 2 , sample size: 7-48g of lichen were irradiated in polyethylene containers and after irradiation transferred to new measurement containers and measured in a device constructed by Gwozdz. The X-RF analysis was performed with a Spectrace 5000 energy dispersive X-ray fluorescence analyzer with a rhodium anode tube for excitation. From the activation analyses, the following elements were determined: Ag, Al, As, Au, Ba, Br, Ca, Cd, Ce, Cl, Co, Cr, Cs, Cu, Dy, Eu, Fe, Hf, Hg, I, K, La, Lu, Mg, Mn, Mo, Na, Nd, Ni, Rb, Sb, Sc, Se, Sr, Ta, Tb, Th, Ti, U, V, Yb, Zn. From the X-RF measurements, the elements Ag, Al, Ba, Br, Ca, Cd, Cu, Fe, I, K, Mg, Mn, P, Pb, Rb, S, Sb, Si, Sn, Sr, Ti, Y, Zn, and Zr were evaluated. From the X-RF data as well as from the AA-data of samples of different weight it is apparent that milling to a particle size of 200m is not sufficient for all elements, especially not for gold, cadmium, and cobalt which may be present as nuggets or accessory heavy minerals. It is therefore advisable to mill the sample to a particle size which is an order of magnitude smaller and remove the not adhering dust, even if this lowers the content of these elements. (author)

  15. Chest radiology in HIV-positive patients with tuberculosis - analysis of 104 cases

    International Nuclear Information System (INIS)

    Camara, C.S.; Moraes, A.P.P. de; Silva, W.A.E.; Camisao, C.C.; Basilio de Oliveira, C.A.; Kisckinhevski, W.; Santos, A.A.S. dos

    1990-01-01

    Radiological examinations from 104 patients HIV-positive with tuberculosis were revised at HUGG/Uni-Rio, during the period from June/86 to June/89. From these, 91.4% were male patients, the predominant risk group was homosexual. Among the women, the most affected group was the intravenous drug consumer. The general age group mostly presented was the one from 20 to 39 years. The main tuberculosis confirmation came from the BAAR research in the sputum (57.6%); the necropsy contributed with 13.5% of the patients. The extrathoracic manifestations occurred in 27% of the cases. The most common radiological patterns were interstitial infiltrate 71.2%, bilateral in 48% of the cases, in the alveolar patterns 63.5%, mostly upper lobes, frequently they were simultaneous. Other important findings were: mediastinal lymphatic involvement, pleural effusion, cavity and X-ray without particularities with pulmonary tuberculosis. A comparison study was performed based on literature data and it was observed atypical patterns for the secondary tuberculosis. (author)

  16. Enhancing the Radiologist-Patient Relationship through Improved Communication: A Quantitative Readability Analysis in Spine Radiology.

    Science.gov (United States)

    Hansberry, D R; Donovan, A L; Prabhu, A V; Agarwal, N; Cox, M; Flanders, A E

    2017-06-01

    More than 75 million Americans have less than adequate health literacy skills according to the National Center for Education Statistics. Readability scores are used as a measure of how well populations read and understand patient education materials. The purpose of this study was to assess the readability of Web sites dedicated to patient education for radiologic spine imaging and interventions. Eleven search terms relevant to radiologic spine imaging were searched on the public Internet, and the top 10 links for each term were collected and analyzed to determine readability scores by using 10 well-validated quantitative readability assessments from patient-centered education Web sites. The search terms included the following: x-ray spine, CT spine, MR imaging spine, lumbar puncture, kyphoplasty, vertebroplasty, discogram, myelogram, cervical spine, thoracic spine, and lumbar spine. Collectively, the 110 articles were written at an 11.3 grade level (grade range, 7.1-16.9). None of the articles were written at the American Medical Association and National Institutes of Health recommended 3rd-to-7th grade reading levels. The vertebroplasty articles were written at a statistically significant ( P readability scores of the articles and the American Medical Association and National Institutes of Health recommended guidelines, it is likely that many patients do not fully benefit from these resources. © 2017 by American Journal of Neuroradiology.

  17. Sensitivity analysis on the priority order of the radiological worker allocation model using goal programming

    International Nuclear Information System (INIS)

    Jung, Hae Yong; Lee, Kun Jai

    1998-01-01

    In nuclear power plant, it has been the important object to reduce the occupational radiation exposure (ORE). Recently, the optimization concept of management science has been studied to reduce the ORE in nuclear power plant. In optimization of the worker allocation, the collective dose, working time, individual dose, and total number of worker must be considered and their priority orders must be thought because the main constraint is necessary for determining the constraints variable of the radiological worker allocation problem. The ultimate object of this study is to look into the change of the optimal allocation of the radiological worker as priority order changes. In this study, the priority order is the characteristic of goal programming that is a kind of multi-objective linear programming. From a result of study using goal programming, the total number of worker and collective dose of worker have changed as the priority order has changed and the collective dose limit have played an important role in reducing the ORE

  18. A preliminary study of DTI Fingerprinting on stroke analysis.

    Science.gov (United States)

    Ma, Heather T; Ye, Chenfei; Wu, Jun; Yang, Pengfei; Chen, Xuhui; Yang, Zhengyi; Ma, Jingbo

    2014-01-01

    DTI (Diffusion Tensor Imaging) is a well-known MRI (Magnetic Resonance Imaging) technique which provides useful structural information about human brain. However, the quantitative measurement to physiological variation of subtypes of ischemic stroke is not available. An automatically quantitative method for DTI analysis will enhance the DTI application in clinics. In this study, we proposed a DTI Fingerprinting technology to quantitatively analyze white matter tissue, which was applied in stroke classification. The TBSS (Tract Based Spatial Statistics) method was employed to generate mask automatically. To evaluate the clustering performance of the automatic method, lesion ROI (Region of Interest) is manually drawn on the DWI images as a reference. The results from the DTI Fingerprinting were compared with those obtained from the reference ROIs. It indicates that the DTI Fingerprinting could identify different states of ischemic stroke and has promising potential to provide a more comprehensive measure of the DTI data. Further development should be carried out to improve DTI Fingerprinting technology in clinics.

  19. FFTF vertical sodium storage tank preliminary thermal analysis

    International Nuclear Information System (INIS)

    Irwin, J.J.

    1995-01-01

    In the FFTF Shutdown Program, sodium from the primary and secondary heat transport loops, Interim Decay Storage (IDS), and Fuel Storage Facility (FSF) will be transferred to four large storage tanks for temporary storage. Three of the storage tanks will be cylindrical vertical tanks having a diameter of 28 feet, height of 22 feet and fabricated from carbon steel. The fourth tank is a horizontal cylindrical tank but is not the subject of this report. The storage tanks will be located near the FFTF in the 400 Area and rest on a steel-lined concrete slab in an enclosed building. The purpose of this work is to document the thermal analyses that were performed to ensure that the vertical FFTF sodium storage tank design is feasible from a thermal standpoint. The key criterion for this analysis is the time to heat up the storage tank containing frozen sodium at ambient temperature to 400 F. Normal operating conditions include an ambient temperature range of 32 F to 120 F. A key parameter in the evaluation of the sodium storage tank is the type of insulation. The baseline case assumed six inches of calcium silicate insulation. An alternate case assumed refractory fiber (Cerablanket) insulation also with a thickness of six inches. Both cases assumed a total electrical trace heat load of 60 kW, with 24 kW evenly distributed on the bottom head and 36 kW evenly distributed on the tank side wall

  20. Preliminary analysis of the proposed BN-600 benchmark core

    International Nuclear Information System (INIS)

    John, T.M.

    2000-01-01

    The Indira Gandhi Centre for Atomic Research is actively involved in the design of Fast Power Reactors in India. The core physics calculations are performed by the computer codes that are developed in-house or by the codes obtained from other laboratories and suitably modified to meet the computational requirements. The basic philosophy of the core physics calculations is to use the diffusion theory codes with the 25 group nuclear cross sections. The parameters that are very sensitive is the core leakage, like the power distribution at the core blanket interface etc. are calculated using transport theory codes under the DSN approximations. All these codes use the finite difference approximation as the method to treat the spatial variation of the neutron flux. Criticality problems having geometries that are irregular to be represented by the conventional codes are solved using Monte Carlo methods. These codes and methods have been validated by the analysis of various critical assemblies and calculational benchmarks. Reactor core design procedure at IGCAR consists of: two and three dimensional diffusion theory calculations (codes ALCIALMI and 3DB); auxiliary calculations, (neutron balance, power distributions, etc. are done by codes that are developed in-house); transport theory corrections from two dimensional transport calculations (DOT); irregular geometry treated by Monte Carlo method (KENO); cross section data library used CV2M (25 group)

  1. Social network analysis in identifying influential webloggers: A preliminary study

    Science.gov (United States)

    Hasmuni, Noraini; Sulaiman, Nor Intan Saniah; Zaibidi, Nerda Zura

    2014-12-01

    In recent years, second generation of internet-based services such as weblog has become an effective communication tool to publish information on the Web. Weblogs have unique characteristics that deserve users' attention. Some of webloggers have seen weblogs as appropriate medium to initiate and expand business. These webloggers or also known as direct profit-oriented webloggers (DPOWs) communicate and share knowledge with each other through social interaction. However, survivability is the main issue among DPOW. Frequent communication with influential webloggers is one of the way to keep survive as DPOW. This paper aims to understand the network structure and identify influential webloggers within the network. Proper understanding of the network structure can assist us in knowing how the information is exchanged among members and enhance survivability among DPOW. 30 DPOW were involved in this study. Degree centrality and betweenness centrality measurement in Social Network Analysis (SNA) were used to examine the strength relation and identify influential webloggers within the network. Thus, webloggers with the highest value of these measurements are considered as the most influential webloggers in the network.

  2. Preliminary analysis of space mission applications for electromagnetic launchers

    Science.gov (United States)

    Miller, L. A.; Rice, E. E.; Earhart, R. W.; Conlon, R. J.

    1984-01-01

    The technical and economic feasibility of using electromagnetically launched EML payloads propelled from the Earth's surface to LEO, GEO, lunar orbit, or to interplanetary space was assessed. Analyses of the designs of rail accelerators and coaxial magnetic accelerators show that each is capable of launching to space payloads of 800 KG or more. A hybrid launcher in which EML is used for the first 2 KM/sec followed by chemical rocket stages was also tested. A cost estimates study shows that one to two EML launches per day are needed to break even, compared to a four-stage rocket. Development models are discussed for: (1) Earth orbital missions; (2) lunar base supply mission; (3) solar system escape mission; (4) Earth escape missions; (5) suborbital missions; (6) electromagnetic boost missions; and (7) space-based missions. Safety factors, environmental impacts, and EML systems analysis are discussed. Alternate systems examined include electrothermal thrustors, an EML rocket gun; an EML theta gun, and Soviet electromagnetic accelerators.

  3. A simplified procedure of linear regression in a preliminary analysis

    Directory of Open Access Journals (Sweden)

    Silvia Facchinetti

    2013-05-01

    Full Text Available The analysis of a statistical large data-set can be led by the study of a particularly interesting variable Y – regressed – and an explicative variable X, chosen among the remained variables, conjointly observed. The study gives a simplified procedure to obtain the functional link of the variables y=y(x by a partition of the data-set into m subsets, in which the observations are synthesized by location indices (mean or median of X and Y. Polynomial models for y(x of order r are considered to verify the characteristics of the given procedure, in particular we assume r= 1 and 2. The distributions of the parameter estimators are obtained by simulation, when the fitting is done for m= r + 1. Comparisons of the results, in terms of distribution and efficiency, are made with the results obtained by the ordinary least square methods. The study also gives some considerations on the consistency of the estimated parameters obtained by the given procedure.

  4. Preliminary Analysis of Slope Stability in Kuok and Surrounding Areas

    Directory of Open Access Journals (Sweden)

    Dewandra Bagus Eka Putra

    2016-12-01

    Full Text Available The level of slope influenced by the condition of the rocks beneath the surface. On high level of slopes, amount of surface runoff and water transport energy is also enlarged. This caused by greater gravity, in line with the surface tilt from the horizontal plane. In other words, topsoil eroded more and more. When the slope becomes twice as steep, then the amount of erosion per unit area be 2.0 - 2.5 times more. Kuok and surrounding area is the road access between the West Sumatra and Riau which plays an important role economies of both provinces. The purpose of this study is to map the locations that have fairly steep slopes and potential mode of landslides. Based on SRTM data obtained,  the roads in Kuok area has a minimum elevation of + 33 m and a maximum  + 217.329 m. Rugged road conditions with slope ranging from 24.08 ° to 44.68 ° causing this area having frequent landslides. The result of slope stability analysis in a slope near the Water Power Plant Koto Panjang, indicated that mode of active failure is toppling failure or rock fall and the potential zone of failure is in the center part of the slope.

  5. Electrical field of electrical appliances versus distance: A preliminary analysis

    International Nuclear Information System (INIS)

    Mustafa, Nur Badariah Ahmad; Nordin, Farah Hani; Ismail, Fakaruddin Ali Ahmad; Alkahtani, Ammar Ahmed; Balasubramaniam, Nagaletchumi; Hock, Goh Chin; Shariff, Z A M

    2013-01-01

    Every household electrical appliance that is plugged in emits electric field even if it is not operating. The source where the appliance is plugged into and the components of household electrical appliance contribute to electric field emission. The electric field may cause unknown disturbance to the environment or also affect the human health and the effect might depends on the strength of the electric field emitted by the appliance. This paper will investigate the strength of the electric field emitted by four different electrical appliances using spectrum analyser. The strength will be captured at three different distances; (i) 1m (ii) 2m and (iii) 3m and analysis of the strength of the electrical field is done based on the three different distances. The measurement results show that the strength of the electric field is strongest when it is captured at 1m and the weakest at 3m from the electrical appliance. The results proved that the farther an object is located from the electrical appliance; the less effect the magnetic field has.

  6. Gas cooled fast reactor 2400 MWTh, status on the conceptual design studies and preliminary safety analysis

    International Nuclear Information System (INIS)

    Malo, J.Y.; Alpy, N.; Bentivoglio, F.

    2009-01-01

    The Gas cooled Fast Reactor (GFR) is considered by the French Commissariat a l'Energie Atomique as a promising concept, combining the benefits of fast spectrum and high temperature, using Helium as coolant. A status on the GFR preliminary viability was made at the end of 2007, ending the pre-conceptual design phase. A consistent overall systems arrangement was proposed and a preliminary safety analysis based on operating transient calculations and a simplified PSA had established a global confidence in the feasibility and safety of this baseline concept. Its potential for attractive performances had been pointed out. Compare to the more mature Sodium Fast Reactor technology, no demonstrator has ever been built and the feasibility demonstration will required a longer lead time. The next main project milestone is related to the GFR viability, scheduled in 2012. The current studies consist in revisiting the reactor reference design options as selected at the end of 2007. Most of them are being consolidated by going more in depth in the analysis. Some possible alternatives are assessed. The paper will give a status on the last studies performed on the core design and corresponding neutronics and cycle performance, the Decay Heat Removal strategy and preliminary safety analysis, systems design and balance of plant... This paper is complementary to the Icapp'09 papers 9062 dealing with the Gas cooled Fast Reactor Demonstrator ALLEGRO and 9378 related to GFR transients analysis. (author)

  7. Clinical registry for rheumatoid arthritis; a preliminary analysis

    International Nuclear Information System (INIS)

    Fakhr, A.; Hakim, F.; Zaidi, S.K.; Sharif, A.

    2017-01-01

    To establish a clinical registry for Rheumatoid Arthritis and delineate the most common symptoms that rheumatoid arthritis (RA) patients experience in our set up. Study Design: Cross sectional study. Place and Duration of Study: Study was carried out at Military Hospital (MH) Rawalpindi at Rheumatology Department during the period of Jan 2013 to Jun 2015. Material and Methods: A clinical registry for Rheumatoid Arthritis was developed as per criteria jointly developed by American College of Rheumatology (ACR) along with European League against Rheumatism (EULAR) (2010). Fifty-eight patients were registered after their informed consent and approval by Military Hospital (MH) Rawalpindi ethical committee. Age, gender and relevant clinical parameters of RA patients were recorded on case report forms and stored for analysis in the RA registry in Excel 2010. The figures were reported in frequencies and percentages. Results: Multiple joint pains (48.28%), fever (24.14%), morning stiffness of joints (22.41%) were the most common symptoms in RA patients. Other clinical manifestations included painful bilateral swollen joints (13.79%), pain in different parts of the body (10.34%), Raynaud's phenomenon (10.34%), malaise (8.62%), swollen body parts (8.62%), ulcers (8.62%), fatigue (6.90%), nodules on skin/elbow/interphalangeal joints (6.90%), deformities of fingers/ hand (3.45%), redness of eyes (3.45%), body rash (3.45%), inability to walk (3.45%), cervical lymphadenopathy (1.72%), stiffness of spine (1.72%) and myalgias (1.72%). Conclusion: It is concluded that multiple joint pains, fever and morning stiffness of joints are the most common symptoms of RA patients. (author)

  8. Advanced analysis of finger-tapping performance: a preliminary study.

    Science.gov (United States)

    Barut, Cağatay; Kızıltan, Erhan; Gelir, Ethem; Köktürk, Fürüzan

    2013-06-01

    The finger-tapping test is a commonly employed quantitative assessment tool used to measure motor performance in the upper extremities. This task is a complex motion that is affected by external stimuli, mood and health status. The complexity of this task is difficult to explain with a single average intertap-interval value (time difference between successive tappings) which only provides general information and neglects the temporal effects of the aforementioned factors. This study evaluated the time course of average intertap-interval values and the patterns of variation in both the right and left hands of right-handed subjects using a computer-based finger-tapping system. Cross sectional study. Thirty eight male individuals aged between 20 and 28 years (Mean±SD = 22.24±1.65) participated in the study. Participants were asked to perform single-finger-tapping test for 10 seconds of test period. Only the results of right-handed (RH) 35 participants were considered in this study. The test records the time of tapping and saves data as the time difference between successive tappings for further analysis. The average number of tappings and the temporal fluctuation patterns of the intertap-intervals were calculated and compared. The variations in the intertap-interval were evaluated with the best curve fit method. An average tapping speed or tapping rate can reliably be defined for a single-finger tapping test by analysing the graphically presented data of the number of tappings within the test period. However, a different presentation of the same data, namely the intertap-interval values, shows temporal variation as the number of tapping increases. Curve fitting applications indicate that the variation has a biphasic nature. The measures obtained in this study reflect the complex nature of the finger-tapping task and are suggested to provide reliable information regarding hand performance. Moreover, the equation reflects both the variations in and the general

  9. Diisocyanate emission from a paint product: a preliminary analysis.

    Science.gov (United States)

    Jarand, Curtis W; Akapo, Samuel O; Swenson, Lonie J; Kelman, Bruce J

    2002-07-01

    Exposure of workers to diisocyanates in the polyurethane foam manufacturing industry is well documented. However, very little quantitative data have been published on exposure to diisocyanates from the use of paints and coatings. The purpose of this study was to evaluate emission of 2,4-toluene diisocyanate, 2,6-toluene diisocyanate (2,6-TDI), and isophorone diisocyanate from a commercially available two-stage concrete coating and sealant. A laboratory model of an outdoor deck coating process was developed and diisocyanate concentrations determined by derivatization with 1-(2-methoxyphenol)-piperazine and subsequent high performance liquid chromatographic analysis with UV detection. The detection limit for 2,4-toluene diisocyanate and 2,6-toluene diisocyanate urea derivatives was 0.6 microg TDI/gm wet product, and 0.54 microg IPDI/gm wet product for the isophorone diisocyanate urea derivative. No 2,4-toluene diisocyanate or isophorone diisocyanate was detected in the mixed product. A maximum mean 2,6-TDI emission rate of 0.32 microg of 2,6-TDI/gram of wet product applied/hour was observed for the 1-hour sampling time, 0.38 microg of 2,6-TDI/gram of wet product applied/hour was observed for the 5-hour sampling time, and 0.02 micrpg of 2,6-TDI/gram of wet product applied/hour was observed for the 15-hour sampling time. The decrease in rate of 2,6-TDI emission over the 15-hour period indicates that emission of 2,6-TDI is virtually complete after 5 hours. These emission rates should allow industrial hygienists to calculate exposures to isocyanates emitted from at least one curing sealant.

  10. Thermoluminescent dosemeters characterization for patient dosimetry in diagnostic radiology preliminary results;Caracterizacao de dosimetros termoluminescentes para dosimetria de pacientes em radiodiagnostico - resultados iniciais

    Energy Technology Data Exchange (ETDEWEB)

    Castro, William J.; Squair, Peterson L. [Faculdade Novo Rumo, Belo Horizonte, MG (Brazil); Centro de Desenvolvimento de Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Gonzaga, Natalia B. [Universidade Unincor, Belo Horizonte, MG (Brazil); Centro de Desenvolvimento de Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Nogueira, Maria S.; Silva, Teogenes A. da [Centro de Desenvolvimento de Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2009-07-01

    The determination of the metrological characteristics of thermoluminescent (TL) dosimeters plays an important role in dosimetry of patients submitted to x-ray examinations for diagnostic purpose. Entrance surface doses can be measured with TL dosimeters to verify the compliance with the diagnostic reference levels. Organ doses can be estimated through TL measurements in an anthropomorphic phantom which it allows the radiation risk assessment. In this work, LiF:Mg,Ti (TLD-100) rod and chip thermoluminescent dosimeters were characterized considering their use for patient dosimetry in computerized tomography and mammography. Preliminary results showed that TL dosimeters have a response reproducibility of 7.8% and 4.8% and homogeneity of 18.4% and 6.5% for rod and chip shapes, respectively. (author)

  11. Cognitive Task Analysis of Business Jet Pilots' Weather Flying Behaviors: Preliminary Results

    Science.gov (United States)

    Latorella, Kara; Pliske, Rebecca; Hutton, Robert; Chrenka, Jason

    2001-01-01

    This report presents preliminary findings from a cognitive task analysis (CTA) of business aviation piloting. Results describe challenging weather-related aviation decisions and the information and cues used to support these decisions. Further, these results demonstrate the role of expertise in business aviation decision-making in weather flying, and how weather information is acquired and assessed for reliability. The challenging weather scenarios and novice errors identified in the results provide the basis for experimental scenarios and dependent measures to be used in future flight simulation evaluations of candidate aviation weather information systems. Finally, we analyzed these preliminary results to recommend design and training interventions to improve business aviation decision-making with weather information. The primary objective of this report is to present these preliminary findings and to document the extended CTA methodology used to elicit and represent expert business aviator decision-making with weather information. These preliminary findings will be augmented with results from additional subjects using this methodology. A summary of the complete results, absent the detailed treatment of methodology provided in this report, will be documented in a separate publication.

  12. Crystallization and preliminary X-ray diffraction analysis of rat autotaxin

    International Nuclear Information System (INIS)

    Day, Jacqueline E.; Hall, Troii; Pegg, Lyle E.; Benson, Timothy E.; Hausmann, Jens; Kamtekar, Satwik

    2010-01-01

    Autotaxin (ATX), a pyrophosphatase/phosphodiesterase enzyme, is a promising drug target for many indications and is only distantly related to enzymes of previously determined structure. Here, the cloning, expression, purification, crystallization and preliminary diffraction analysis of ATX are reported. Rat autotaxin has been cloned, expressed, purified to homogeneity and crystallized via hanging-drop vapour diffusion using PEG 3350 as precipitant and ammonium iodide and sodium thiocyanate as salts. The crystals diffracted to a maximum resolution of 2.05 Å and belonged to space group P1, with unit-cell parameters a = 53.8, b = 63.3, c = 70.5 Å, α = 98.8, β = 106.2, γ = 99.8°. Preliminary X-ray diffraction analysis indicated the presence of one molecule per asymmetric unit, with a solvent content of 47%

  13. Relative risk analysis in regulating the use of radiation-emitting medical devices. A preliminary application

    Energy Technology Data Exchange (ETDEWEB)

    Jones, E.D.; Banks, W.W.; Altenbach, T.J.; Fischer, L.E. [Lawrence Livermore National Lab., CA (United States)

    1995-09-01

    This report describes a preliminary application of an analysis approach for assessing relative risks in the use of radiation- emitting medical devices. Results are presented on human-initiated actions and failure modes that are most likely to occur in the use of the Gamma Knife, a gamma irradiation therapy device. This effort represents an initial step in a US Nuclear Regulatory Commission (NRC) plan to evaluate the potential role of risk analysis in regulating the use of nuclear medical devices. For this preliminary application of risk assessment, the focus was to develop a basic process using existing techniques for identifying the most likely risk contributors and their relative importance. The approach taken developed relative risk rankings and profiles that incorporated the type and quality of data available and could present results in an easily understood form. This work was performed by the Lawrence Livermore National Laboratory for the NRC.

  14. Crystallization and preliminary X-ray diffraction analysis of West Nile virus

    International Nuclear Information System (INIS)

    Kaufmann, Bärbel; Plevka, Pavel; Kuhn, Richard J.; Rossmann, Michael G.

    2010-01-01

    Crystals of infectious West Nile virus were obtained and diffracted at best to about 25 Å resolution. Preliminary analysis of the diffraction pattern suggested tight hexagonal packing of the intact virus. West Nile virus, a human pathogen, is closely related to other medically important flaviviruses of global impact such as dengue virus. The infectious virus was purified from cell culture using polyethylene glycol (PEG) precipitation and density-gradient centrifugation. Thin amorphously shaped crystals of the lipid-enveloped virus were grown in quartz capillaries equilibrated by vapor diffusion. Crystal diffraction extended at best to a resolution of about 25 Å using synchrotron radiation. A preliminary analysis of the diffraction images indicated that the crystals had unit-cell parameters a ≃ b ≃ 480 Å, γ = 120°, suggesting a tight hexagonal packing of one virus particle per unit cell

  15. Preliminary Dynamic Feasibility and Analysis of a Spherical, Wind-Driven (Tumbleweed), Martian Rover

    Science.gov (United States)

    Flick, John J.; Toniolo, Matthew D.

    2005-01-01

    The process and findings are presented from a preliminary feasibility study examining the dynamics characteristics of a spherical wind-driven (or Tumbleweed) rover, which is intended for exploration of the Martian surface. The results of an initial feasibility study involving several worst-case mobility situations that a Tumbleweed rover might encounter on the surface of Mars are discussed. Additional topics include the evaluation of several commercially available analysis software packages that were examined as possible platforms for the development of a Monte Carlo Tumbleweed mission simulation tool. This evaluation lead to the development of the Mars Tumbleweed Monte Carlo Simulator (or Tumbleweed Simulator) using the Vortex physics software package from CM-Labs, Inc. Discussions regarding the development and evaluation of the Tumbleweed Simulator, as well as the results of a preliminary analysis using the tool are also presented. Finally, a brief conclusions section is presented.

  16. Preliminary X-ray analysis of twinned crystals of sarcosine dimethylglycine methyltransferase from Halorhodospira halochoris

    International Nuclear Information System (INIS)

    Kallio, Juha Pekka; Jänis, Janne; Nyyssölä, Antti; Hakulinen, Nina; Rouvinen, Juha

    2009-01-01

    The crystallization and preliminary X-ray diffraction analysis of sarcosine dimethylglycine methyltransferase from H. halochoris is reported. Sarcosine dimethylglycine methyltransferase (EC 2.1.1.157) is an enzyme from the extremely halophilic anaerobic bacterium Halorhodospira halochoris. This enzyme catalyzes the twofold methylation of sarcosine to betaine, with S-adenosylmethionine (AdoMet) as the methyl-group donor. This study presents the crystallization and preliminary X-ray analysis of recombinant sarcosine dimethylglycine methyltransferase produced in Escherichia coli. Mass spectroscopy was used to determine the purity and homogeneity of the enzyme material. Two different crystal forms, which initially appeared to be hexagonal and tetragonal, were obtained. However, on analyzing the diffraction data it was discovered that both crystal forms were pseudo-merohedrally twinned. The true crystal systems were monoclinic and orthorhombic. The monoclinic crystal diffracted to a maximum of 2.15 Å resolution and the orthorhombic crystal diffracted to 1.8 Å resolution

  17. Preliminary Disposal Analysis for Selected Accelerator Production of Tritium Waste Streams

    International Nuclear Information System (INIS)

    Ades, M.J.; England, J.L.

    1998-06-01

    A preliminary analysis was performed for two selected Accelerator Production of Tritium (APT) generated mixed and low-level waste streams to determine if one mixed low-level waste (MLLW) stream that includes the Mixed Waste Lead (MWL) can be disposed of at the Nevada Test Site (NTS) and at the Hanford Site and if one low-level radioactive waste (LLW) stream, that includes the Tungsten waste stream (TWS) generated by the Tungsten Neutron Source modules and used in the Target/Blanket cavity vessel, can be disposed of in the LLW Vaults at the Savannah River Plant (SRP). The preliminary disposal analysis that the radionuclide concentrations of the two selected APT waste streams are not in full compliance with the Waste Acceptance Criteria (WAC) and the Performance Assessment (PA) radionuclide limits of the disposal sites considered

  18. Relative risk analysis in regulating the use of radiation-emitting medical devices. A preliminary application

    International Nuclear Information System (INIS)

    Jones, E.D.; Banks, W.W.; Altenbach, T.J.; Fischer, L.E.

    1995-09-01

    This report describes a preliminary application of an analysis approach for assessing relative risks in the use of radiation- emitting medical devices. Results are presented on human-initiated actions and failure modes that are most likely to occur in the use of the Gamma Knife, a gamma irradiation therapy device. This effort represents an initial step in a US Nuclear Regulatory Commission (NRC) plan to evaluate the potential role of risk analysis in regulating the use of nuclear medical devices. For this preliminary application of risk assessment, the focus was to develop a basic process using existing techniques for identifying the most likely risk contributors and their relative importance. The approach taken developed relative risk rankings and profiles that incorporated the type and quality of data available and could present results in an easily understood form. This work was performed by the Lawrence Livermore National Laboratory for the NRC

  19. National Data Center Preparedness Exercise 2015 (NPE 2015): MY-NDC Preliminary Analysis Result

    International Nuclear Information System (INIS)

    Faisal Izwan Abdul Rashid; Muhammed Zulfakar Zolkaffly

    2016-01-01

    Malaysia has established the CTBT National Data Centre (MY-NDC) in December 2005. MY-NDC is tasked to perform Comprehensive Nuclear-Test-Ban-Treaty (CTBT) data management as well as provide information for Treaty related events to Nuclear Malaysia as CTBT National Authority. In 2015, MY-NDC has participated in the National Data Centre Preparedness Exercise 2015 (NPE 2015). This paper aims at presenting MY-NDC preliminary analysis result of NPE 2015. In NPE 2015, MY-NDC has performed five different analyses, namely, radionuclide, atmospheric transport modelling (ATM), data fusion, seismic analysis and site forensics. The preliminary findings show the hypothetical scenario in NPE 2015 most probably is an uncontained event resulted high release of radionuclide to the air. (author)

  20. Preliminary safety analysis of the HTTR-IS nuclear hydrogen production system

    International Nuclear Information System (INIS)

    Sato, Hiroyuki; Ohashi, Hirofumi; Tazawa, Yujiro; Tachibana, Yukio; Sakaba, Nariaki

    2010-06-01

    Japan Atomic Energy Agency is planning to demonstrate hydrogen production by thermochemical water-splitting IS process utilizing heat from the high-temperature gas-cooled reactor HTTR (HTTR-IS system). The previous study identified that the HTTR modification due to the coupling of hydrogen production plant requires an additional safety review since the scenario and quantitative values of the evaluation items would be altered from the original HTTR safety review. Hence, preliminary safety analyses are conducted by using the system analysis code. Calculation results showed that evaluation items such as a coolant pressure, temperatures of heat transfer tubes at the pressure boundary, etc., did not exceed allowable values. Also, the peak fuel temperature did not exceed allowable value and therefore the reactor core was not damaged and cooled sufficiently. This report compiles calculation conditions, event scenarios and the calculation results of the preliminary safety analysis. (author)

  1. Preliminary Hazards Analysis of K-Basin Fuel Encapsulation and Storage

    International Nuclear Information System (INIS)

    Strickland, G.C.

    1994-01-01

    This Preliminary Hazards Analysis (PHA) systematically examines the K-Basin facilities and their supporting systems for hazards created by abnormal operating conditions and external events (e.g., earthquakes) which have the potential for causing undesirable consequences to the facility worker, the onsite individual, or the public. The operational activities examined are fuel encapsulation, fuel storage and cooling. Encapsulation of sludges in the basins is not examined. A team of individuals from Westinghouse produced a set of Hazards and Operability (HAZOP) tables documenting their examination of abnormal process conditions in the systems and activities examined in K-Basins. The purpose of this report is to reevaluate and update the HAZOP in the original Preliminary Hazard Analysis of K-Basin Fuel Encapsulation and Storage originally developed in 1991

  2. Preliminary spatial analysis of combined BATSE/Ulysses gamma-ray burst locations

    International Nuclear Information System (INIS)

    Kippen, R. Marc; Hurley, Kevin; Pendleton, Geoffrey N.

    1998-01-01

    We present the preliminary spatial analysis of 278 bursts that have been localized by BATSE and the two-spacecraft Compton/Ulysses Interplanetary Network. The large number and superior accuracy of the combined BATSE/Ulysses locations provides improved sensitivity to small-angle source properties. We find that the locations are consistent with large- and small-scale isotropy, with no significant small-angle clustering. We constrain the fraction of sources in clusters and discuss the implications for burst repetition

  3. Sludge Treatment Project Engineered Container Retrieval And Transfer System Preliminary Design Hazard Analysis Supplement 1

    International Nuclear Information System (INIS)

    Franz, G.R.; Meichle, R.H.

    2011-01-01

    This 'What/If' Hazards Analysis addresses hazards affecting the Sludge Treatment Project Engineered Container Retrieval and Transfer System (ECRTS) NPH and external events at the preliminary design stage. In addition, the hazards of the operation sequence steps for the mechanical handling operations in preparation of Sludge Transport and Storage Container (STSC), disconnect STSC and prepare STSC and Sludge Transport System (STS) for shipping are addressed.

  4. Preliminary Failure Modes and Effects Analysis of the US DCLL Test Blanket Module

    Energy Technology Data Exchange (ETDEWEB)

    Lee C. Cadwallader

    2010-06-01

    This report presents the results of a preliminary failure modes and effects analysis (FMEA) of a small tritium-breeding test blanket module design for the International Thermonuclear Experimental Reactor. The FMEA was quantified with “generic” component failure rate data, and the failure events are binned into postulated initiating event families and frequency categories for safety assessment. An appendix to this report contains repair time data to support an occupational radiation exposure assessment for test blanket module maintenance.

  5. Preliminary Failure Modes and Effects Analysis of the US DCLL Test Blanket Module

    Energy Technology Data Exchange (ETDEWEB)

    Lee C. Cadwallader

    2007-08-01

    This report presents the results of a preliminary failure modes and effects analysis (FMEA) of a small tritium-breeding test blanket module design for the International Thermonuclear Experimental Reactor. The FMEA was quantified with “generic” component failure rate data, and the failure events are binned into postulated initiating event families and frequency categories for safety assessment. An appendix to this report contains repair time data to support an occupational radiation exposure assessment for test blanket module maintenance.

  6. Preliminary Failure Modes and Effects Analysis of the US DCLL Test Blanket Module

    International Nuclear Information System (INIS)

    Lee C. Cadwallader

    2007-01-01

    This report presents the results of a preliminary failure modes and effects analysis (FMEA) of a small tritium-breeding test blanket module design for the International Thermonuclear Experimental Reactor. The FMEA was quantified with 'generic' component failure rate data, and the failure events are binned into postulated initiating event families and frequency categories for safety assessment. An appendix to this report contains repair time data to support an occupational radiation exposure assessment for test blanket module maintenance

  7. Evaluation of Current Computer Models Applied in the DOE Complex for SAR Analysis of Radiological Dispersion & Consequences

    Energy Technology Data Exchange (ETDEWEB)

    O' Kula, K. R. [Savannah River Site (SRS), Aiken, SC (United States); East, J. M. [Savannah River Site (SRS), Aiken, SC (United States); Weber, A. H. [Savannah River Site (SRS), Aiken, SC (United States); Savino, A. V. [Savannah River Site (SRS), Aiken, SC (United States); Mazzola, C. A. [Savannah River Site (SRS), Aiken, SC (United States)

    2003-01-01

    The evaluation of atmospheric dispersion/ radiological dose analysis codes included fifteen models identified in authorization basis safety analysis at DOE facilities, or from regulatory and research agencies where past or current work warranted inclusion of a computer model. All computer codes examined were reviewed using general and specific evaluation criteria developed by the Working Group. The criteria were based on DOE Orders and other regulatory standards and guidance for performing bounding and conservative dose calculations. Included were three categories of criteria: (1) Software Quality/User Interface; (2) Technical Model Adequacy; and (3) Application/Source Term Environment. A consensus-based limited quantitative ranking process was used to base an order of model preference as both an overall conclusion, and under specific conditions.

  8. Radiological protection

    International Nuclear Information System (INIS)

    Azorin N, J.; Azorin V, J. C.

    2010-01-01

    This work is directed to all those people related with the exercise of the radiological protection and has the purpose of providing them a base of knowledge in this discipline so that they can make decisions documented on technical and scientist factors for the protection of the personnel occupationally exposed, the people in general and the environment during the work with ionizing radiations. Before de lack of a text on this matter, this work seeks to cover the specific necessities of our country, providing a solid presentation of the radiological protection, included the bases of the radiations physics, the detection and radiation dosimetry, the radiobiology, the normative and operational procedures associates, the radioactive wastes, the emergencies and the transport of the radioactive material through the medical and industrial applications of the radiations, making emphasis in the relative particular aspects to the radiological protection in Mexico. The book have 16 chapters and with the purpose of supplementing the given information, are included at the end four appendixes: 1) the radioactive waste management in Mexico, 2-3) the Mexican official standards related with the radiological protection, 4) a terms glossary used in radiological protection. We hope this book will be of utility for those people that work in the investigation and the applications of the ionizing radiations. (Author)

  9. The radiological 'second opinion' online through the Internet. Report on implementation and analysis of the diagnostic certainty of transmitted images

    International Nuclear Information System (INIS)

    Ricke, J.; Donk, E. van der; Ostendorf, B.; Zielinski, C.; Liebig, T.; Stroszczinski, C.; Loez-Haenninen, E.; Lemke, A.J.; Gillessen, C.; Guervit, Oe.; Amthauer, H.; Kleinholz, L.; Bartelink, H.

    1997-01-01

    Numerous medical on-line services have already been established in the world-wide Internet. In connection with the Information service TELESCAN, sponsored by the EU, a pilot project has been initiated which offers a radiological 'second opinion' via the transmission of radiological findings and images that have been previously rendered anonymous. In addition to a description of the basic implementation, tests of the diagnostic certainty of the transmitted over the Internet, and then evaluated on the receiver's monitor. Both the transfer of originally generated digital image files (in ACR-NEMA or DICOM) as well as graphic files after digitization of X-ray films, for example by a document camera, is possible via e-mail. Visualization by the receiver requires the use of current proprietary software for special medical image formats, while standard graphic formats such as GIFF or JPEG can be visualized with the usual Internet software. In an ROC analysis, 56 individual images of cranial computed tomographs, half with pathological findings such as space-occupying lesions, infarcts, or brain edema, were tested with regard to the diagnostic certainty after digitization and transmission. In comparison with the original film findings, there was a slight but statistically not significant reduction in diagnostic certainty of the images evaluated on screen after transfer via the Internet. We believe that this result is due to the low local resolution, low dynamic range, the high image noise and of CT arising from the window technique. The same parameters are probably valid for MRI. (orig.) [de

  10. Illicit trafficking of radiological and nuclear materials: modeling and analysis of trafficking trends and risks

    International Nuclear Information System (INIS)

    York, David L.; Love, Tracia L.; Rochau, Gary Eugene

    2005-01-01

    Concerns over the illicit trafficking of radiological and nuclear materials were focused originally on the lack of security and accountability of such material throughout the former Soviet states. This is primarily attributed to the frequency of events that have occurred involving the theft and trafficking of critical material components that could be used to construct a Radiological Dispersal Device (RDD) or even a rudimentary nuclear device. However, with the continued expansion of nuclear technology and the deployment of a global nuclear fuel cycle these materials have become increasingly prevalent, affording a more diverse inventory of dangerous materials and dual-use items. To further complicate the matter, the list of nuclear consumers has grown to include: (1) Nation-states that have gone beyond the IAEA agreed framework and additional protocols concerning multiple nuclear fuel cycles and processes that reuse the fuel through reprocessing to exploit technologies previously confined to the more industrialized world; (2) Terrorist organizations seeking to acquire nuclear and radiological material due to the potential devastation and psychological effect of their use; (3) Organized crime, which has discovered a lucrative market in trafficking of illicit material to international actors and/or countries; and (4) Amateur smugglers trying to feed their families in a post-Soviet era. An initial look at trafficking trends of this type seems scattered and erratic, localized primarily to a select group of countries. This is not necessarily the case. The success with which other contraband has been smuggled throughout the world suggests that nuclear trafficking may be carried out with relative ease along the same routes by the same criminals or criminal organizations. Because of the inordinately high threat posed by terrorist or extremist groups acquiring the ingredients for unconventional weapons, it is necessary that illicit trafficking of these materials be better

  11. Multi-criteria analysis to support decision-making process in the event of radiological emergency in tropical climate countries

    International Nuclear Information System (INIS)

    Pereira, Jose F.; Rochedo, Elaine R.R.; Wasserman, Maria A.V.; Silva, Diogo N.G.

    2008-01-01

    Full text: The Multi-criteria Analysis has been widely used in the most diverse areas of the knowledge such as Economy, Transport, Industry, Production, among others. The Multi-criteria Analysis aims to support the decision process, based on the comparison of alternatives, leading to the recommendation of optimized actions in support to decision makers. One of the permanent concerns in the international scenario is the study of the nuclear/radiological consequences of accidents and other events that lead to the contamination of the environment and the exposure of members of the public as a consequence of this contamination. The Multi-criteria Analysis Method is already being used for similar applications in some European countries but it is necessary that the criteria are established taking in account economic, social and climatic aspects that can affect the selection of protective measures applicable to specific regions, and the selection of the different weights to be associated to the different criteria that are to be applied to different social-politic environments. The present work describes the development, already in advanced phase, of a Multi-criteria tool to support the decision making process for the implementation of protective measures to protect the public in situations of radiological accidents, with the degree of flexibility to be easily adapted to the different social, political and climatic regions of Brazil, through the comparison of different options considering a diversity of aspects, such as the efficiency of the measure in the reducing public exposure, the radiation doses that would be received by the workers, the characteristics of the generated wastes, the difficulty of implementation of the measures, as well as the operational costs related to the implementation of the measures. The aim of such analysis is to supply an optimized guidance, under the point of view of radiological protection, adequate for different types of environments that

  12. Preliminary crystallographic analysis of a possible transcription factor encoded by the mimivirus L544 gene

    International Nuclear Information System (INIS)

    Ciaccafava, Alexandre; Lartigue, Audrey; Mansuelle, Pascal; Jeudy, Sandra; Abergel, Chantal

    2011-01-01

    The mimivirus L544 gene product was expressed in E. coli and crystallized; preliminary phasing of a MAD data set was performed using the selenium signal present in a crystal of recombinant selenomethionine-substituted protein. Mimivirus is the prototype of a new family (the Mimiviridae) of nucleocytoplasmic large DNA viruses (NCLDVs), which already include the Poxviridae, Iridoviridae, Phycodnaviridae and Asfarviridae. Mimivirus specifically replicates in cells from the genus Acanthamoeba. Proteomic analysis of purified mimivirus particles revealed the presence of many subunits of the DNA-directed RNA polymerase II complex. A fully functional pre-transcriptional complex appears to be loaded in the virions, allowing mimivirus to initiate transcription within the host cytoplasm immediately upon infection independently of the host nuclear apparatus. To fully understand this process, a systematic study of mimivirus proteins that are predicted (by bioinformatics) or suspected (by proteomic analysis) to be involved in transcription was initiated by cloning and expressing them in Escherichia coli in order to determine their three-dimensional structures. Here, preliminary crystallographic analysis of the recombinant L544 protein is reported. The crystals belonged to the orthorhombic space group C222 1 with one monomer per asymmetric unit. A MAD data set was used for preliminary phasing using the selenium signal present in a selenomethionine-substituted protein crystal

  13. Phosphategypsum wastes in Venice lagoon. Radiological impact; Le discariche di fosfogessi nella laguna di Venezia. Valutazioni preliminari dell'impatto radiologico

    Energy Technology Data Exchange (ETDEWEB)

    Belli, M; Blasi, M; Guogang, J.; Rosamilia, S.; Sansone, U. [Agenzia Nazionale per la Protezione dell' Ambiente, Rome (Italy); Biancotto, R.; Bidoli, P.; Sepulcri, D. [Agenzia Regionale di Prevenzione e Protezione del Veneto, Venice (Italy). Dipt. provinciale di Venezia; Cavolo, F. [Smilax, Mira, VE (Italy)

    2000-07-01

    The phosphoric minerals utilized in phosphoric acid production, presents high concentrations of radioactive materials: U238, Th 232, K 40. The phosphogypsum is the waste material obtained in the phosphoric acid production in wet process. This type of production method is employed for many years in Venice lagoon (Porto Marghera chemical plants). In this paper are reported evaluations of radiological impact on aquatic environment of lagoon. [Italian] Con il termine di fosfogessi si intende comunemente il materiale di risulta che si ottiene nella produzione di acido fosforico attraverso la via umida (attacco acido). Questa tipologia di produzione che ha operato per diversi decenni a Porto Marghera, e' finalizzata allo scopo di ottenere acido fosforico principalmente per l'industria dei fertilizzanti e quindi come prodotto intermedio per la chimica e per le preparazioni alimentari. Il fosforo, elemento principale della reazione, era ricavato da rocce fosfatiche di origine sedimentaria marina provenienti per lo piu' dall'Africa settentrionale. Il sistema produttivo utilizzato negli impianti di Porto Marghera era basato su una reazione principale, che partendo dal minerale attraverso un attacco acido, produceva acido fosforico: Ca{sub 3}(PO{sub 4}){sub 2} (Minerale Fosforico) + 3H{sub 2}SO{sub 4} (Acido Solforico) + 3H{sub 2}O (Acqua) {yields} 2H{sub 3}PO{sub 4} (Acido fosforico) + 3CaSO{sub 4}H{sub 2}O (Solfato di calcio (gesso)). In particolare il minerale era preventivamente macinato e vagliato, quindi si procedeva alla sua miscelazione con l'acido fosforico ed alla successiva reazione del composto ottenuto.

  14. Comparison and applicability analysis of models for estimating radiological dose rates of freshwater biota

    Science.gov (United States)

    Zhang, Xiaofeng; Yang, Zongzhen; Qin, Chunli

    2018-01-01

    A number of inter-comparisons of non-human biota radiation assessment models have been fulfilled by international researchers and organizations. This paper describes the radiological impact to reference biota in Chinese inland nuclear power plant scenario, by using RESRAD-Biota, ERICA and R&D 128. The estimation results are ranging from 6.1×10-3μGy/h to 6.17×10-2μGy/h, mainly contributed by 134Cs and 137Cs, obviously below recommended limits and thus prove the biota in reservoir can be adequately protected from effluent discharge. By comparing models characteristics and performances in exercise, we conclude the ERICA tool reveals more applicability in Chinese nuclear sites and propose several suggestions to establish native framework for non-human biota assessment.

  15. An analysis of the transient's social behavior in the radiological emergency planning zone

    International Nuclear Information System (INIS)

    Bang, Sun Young; Lee, Gab Bock; Chung, Yang Geun; Lee, Jae Eun

    2007-01-01

    The purpose of this study is to analyze the social behavior, especially, the evacuation-related social behavior, of the transients in the radiological Emergency Planning Zone (EPZ) of nuclear power plants. So, the meaning and kinds of the evacuation and the significance of the Trip Generation Time (TGT) have been reviewed. The characteristics of the social behavior of the transient around Ulchin, Wolsong and Kori sites was analyzed through field surveys by using the questionnaire. The major findings of this research implications are as follows. First, for securing the safe evacuation, the alternatives to effectively provide the information on the evacuation warning may be prepared. Second, it is necessary to establish the education and training of transient's evacuation. Third, it is needed that the cause and background of the evacuation refusal are identified and the new response plan to secure transient's safety is prepared

  16. Degraded core accidents for the Sizewell PWR A sensitivity analysis of the radiological consequences

    CERN Document Server

    Kelly, G N; Clarke, R H; Ferguson, L; Haywood, S M; Hemming, C R; Jones, J A

    1982-01-01

    The radiological impact of degraded core accidents postulated for the Sizewell PWR was assessed in an earlier study. In this report the sensitivity of the predicted consequences to variation in the values of a number of important parameters is investigated for one of the postulated accidental releases. The parameters subjected to sensitivity analyses are the dose-mortality relationship for bone marrow irradiation, the energy content of the release, the warning time before the release to the environment, and the dry deposition velocity for airborne material. These parameters were identified as among the more important in determining the uncertainty in the results obtained in the initial study. With a few exceptions the predicted consequences were found to be not very sensitive to the parameter values investigated, the range of variation in the consequences for the limiting values of each parameter rarely exceeded a factor of a few and in many cases was considerably less. The conclusions reached are, however, p...

  17. Numerical analysis of edge effects in side illuminated strip detectors for digital radiology

    CERN Document Server

    Krizaj, D

    2000-01-01

    The influence of edge defects on side illuminated X-ray strip detectors for digital radiology is investigated by numerical device modeling. By assuming positive fixed oxide charges on side and top surfaces simulations have shown strong curvature of the equipotential lines in the edge region. A fraction of the edge generated current surpasses the edge guard-ring junction and is collected by the readout strips. As a consequence, strips cannot be placed close to the edge of the structure and collection efficiency is reduced. An n-on-n instead of a p-on-n strip detector is proposed enabling collection of edge generated carriers by a very narrow guard-ring junction and placement of the readout strip close to the edge without increase of the strip leakage current.

  18. Diagnostic radiology for functional analysis of the cervical vertebral column. Roentgenfunktionsdiagnostik der Halswirbelsaeule

    Energy Technology Data Exchange (ETDEWEB)

    Kamieth, H

    1986-01-01

    The book is averaged in 17 chapters. The first three, introductory chapters dealing with the significance of radiology for the functional diagnosis of the cervical spine are followed by three chapters discussing the movements of the atlantoaxial joints, the statics of the cervical spine, and the sagittal flexural movements in the C2-C7 segments. Subsequent chapters discuss the radiodiagnostical method according to Arlen, the innervation of the cervical spine segments of movement, disturbances of movement including restriction of movement, degenerative processes of the invertebral disks, and hypermobile disturbance of movement. The final chapters deal with compensational and dissociation phenomena, subluxations, defective or compulsive positions, etc., the causes of each, and with the clinical relevance of spondylochondrosis and arthrosis, and with the pain. With 171 figs..

  19. Analysis of radiological features relative to histopathology in 42 skull-base chordomas and chondrosarcomas

    International Nuclear Information System (INIS)

    Pamir, M. Necmettin; Ozduman, Koray

    2006-01-01

    Chordomas and chondrosarcomas are malignant tumors that are reported to have similar clinical presentations and radiological features but different behaviors and outcomes. The aim of this retrospective study was to determine whether specific radiological features of skull-base chordomas or chondrosarcomas are correlated with histopathology, and thus allow preoperative diagnosis. The study involved 32 classic chordomas, 6 chondroid chordomas and 4 chondrosarcomas (42 tumors total). For each case, tumor size and extent, the detailed anatomy involved, and magnetic resonance imaging and computed tomography findings were analyzed. Tumor extent was assessed using a novel method that assessed presence/absence in 18 defined skull-base zones. The chondrosarcomas presented significantly earlier in life than the chordomas (means, 20.5 years versus 36 years, respectively). At time of diagnosis, the median tumor volume was 23 cm 3 (range, 1.2-78.8 cm 3 ) and the mean tumor extent was 6.7 ± 2.9 zones. There were no differences between chordomas and chondrosarcomas, or between the two chordoma subgroups, with respect to lesion volume or extent. Comparison of other imaging findings revealed no features that were diagnostic for either chordoma or chondrosarcoma. The data support previous claims that chondrosarcomas present earlier in life than chordomas, but this finding is not diagnostic. There is wide variation in the extent of skull-base chordomas and chondrosarcomas, and in the specific anatomical structures these tumors involve. None of the MRI or CT features of these tumors appear to be useful for differentiating chordomas from chondrosarcomas preoperatively. For surgical planning, specific, area-oriented definition of tumor extent might provide more useful information than tumor-type classification schemes

  20. Analysis of radiological features relative to histopathology in 42 skull-base chordomas and chondrosarcomas

    Energy Technology Data Exchange (ETDEWEB)

    Pamir, M. Necmettin [Marmara University Faculty of Medicine, Department of Neurosurgery, Istanbul (Turkey)]. E-mail: koray.ozduman@yale.edu; Ozduman, Koray [Marmara University Faculty of Medicine, Department of Neurosurgery, Istanbul (Turkey)

    2006-06-15

    Chordomas and chondrosarcomas are malignant tumors that are reported to have similar clinical presentations and radiological features but different behaviors and outcomes. The aim of this retrospective study was to determine whether specific radiological features of skull-base chordomas or chondrosarcomas are correlated with histopathology, and thus allow preoperative diagnosis. The study involved 32 classic chordomas, 6 chondroid chordomas and 4 chondrosarcomas (42 tumors total). For each case, tumor size and extent, the detailed anatomy involved, and magnetic resonance imaging and computed tomography findings were analyzed. Tumor extent was assessed using a novel method that assessed presence/absence in 18 defined skull-base zones. The chondrosarcomas presented significantly earlier in life than the chordomas (means, 20.5 years versus 36 years, respectively). At time of diagnosis, the median tumor volume was 23 cm{sup 3} (range, 1.2-78.8 cm{sup 3}) and the mean tumor extent was 6.7 {+-} 2.9 zones. There were no differences between chordomas and chondrosarcomas, or between the two chordoma subgroups, with respect to lesion volume or extent. Comparison of other imaging findings revealed no features that were diagnostic for either chordoma or chondrosarcoma. The data support previous claims that chondrosarcomas present earlier in life than chordomas, but this finding is not diagnostic. There is wide variation in the extent of skull-base chordomas and chondrosarcomas, and in the specific anatomical structures these tumors involve. None of the MRI or CT features of these tumors appear to be useful for differentiating chordomas from chondrosarcomas preoperatively. For surgical planning, specific, area-oriented definition of tumor extent might provide more useful information than tumor-type classification schemes.

  1. The Clinician-Educator Pathway in Radiology: An Analysis of Institutional Promotion Criteria.

    Science.gov (United States)

    Jhala, Khushboo; Kim, Jisoo; Chetlen, Alison; Nickerson, Joshua P; Lewis, Petra J

    2017-12-01

    To provide radiology departmental promotional committees and vice chairs of education with a more global perspective on the types of academic activity valued by institutions to aid in their faculty mentoring and standardizing of the Clinician-Educator (ClinEd) pathway. Ninety-two research schools were ranked into three tiers. Ranking was correlated with the presence of a ClinEd track. Thirty promotion documents (ten from each tier) were analyzed to identify common criteria. Differences in guidelines between tiers were assessed by the frequency distribution of criteria. Tier 1 had a significantly greater proportion of schools with a ClinEd track than tier 2 (73% versus 44%, p < 0.05). Thirty-nine criteria were identified and organized into four categories teaching (13), scholarship (12), service/clinical excellence (7), and research (7). The top five included meeting presentations, trainee evaluations, leadership in committees, development of teaching methodologies and materials, and publication of book chapters. First and second tier schools were most similar in frequency distribution. The criteria for the ClinEd promotion track still vary across institutions, though many commonalities exist. A handful of innovative criteria reflect the changing structure of modern health care systems, such as incorporation of online teaching modules and quality improvement efforts. As health care changes, guidelines and incentive structures for faculty should change as well. The information gathered may provide promotion committees with a more global perspective on the types of academic activity valued by modern-day institutions to aid in the national standardization of this pathway and to assist in faculty mentoring. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  2. Radionuclide radiology

    International Nuclear Information System (INIS)

    Scarsbrook, A.F.; Graham, R.N.J.; Perriss, R.W.; Bradley, K.M.

    2006-01-01

    This is the fourth in a series of short reviews of internet-based radiological educational resources, and will focus on radionuclide radiology and nuclear medicine. What follows is a list of carefully selected websites to save time in searching them out. Most of the sites cater for trainee or non-specialist radiologists, but may also be of interest to specialists for use in teaching. This article may be particularly useful to radiologists interested in the rapidly expanding field of positron emission tomography computed tomography (PET-CT). Hyperlinks are available in the electronic version of this article and were all active at the time of going to press (February 2006)

  3. Emergency radiology

    International Nuclear Information System (INIS)

    Keats, T.E.

    1986-01-01

    This book is the German, translated version of the original published in 1984 in the U.S.A., entitled 'Emergency Radiology'. The publication for the most part is made up as an atlas of the radiological images presenting the findings required for assessment of the emergency cases and their first treatment. The test parts' function is to explain the images and give the necessary information. The material is arranged in seven sections dealing with the skull, the facial part of the skull, the spine, thorax, abdominal region, the pelvis and the hip, and the limbs. With 690 figs [de

  4. Postoperative radiology

    International Nuclear Information System (INIS)

    Burhenne, H.J.

    1989-01-01

    This paper reports on the importance of postoperative radiology. Most surgical procedures on the alimentary tract are successful, but postoperative complications remain a common occurrence. The radiologist must be familiar with a large variety of possible surgical complications, because it is this specialty that is most commonly called on to render a definitive diagnosis. The decision for reoperation, for instance, is usually based on results from radiologic imaging techniques. These now include ultrasonography, CT scanning, needle biopsy, and interventional techniques in addition to contrast studies and nuclear medicine investigation

  5. Preliminary CFD Analysis for HVAC System Design of a Containment Building

    Energy Technology Data Exchange (ETDEWEB)

    Son, Sung Man; Choi, Choengryul [ELSOLTEC, Yongin (Korea, Republic of); Choo, Jae Ho; Hong, Moonpyo; Kim, Hyungseok [KEPCO Engineering and Construction, Gimcheon (Korea, Republic of)

    2016-10-15

    HVAC (Heating, Ventilation, Air Conditioning) system has been mainly designed based on overall heat balance and averaging concepts, which is simple and useful for designing overall system. However, such a method has the disadvantage that cannot predict the local flow and temperature distributions in a containment building. In this study, a CFD (Computational Fluid Dynamics) preliminary analysis is carried out to obtain detailed flow and temperature distributions in a containment building and to ensure that such information can be obtained via CFD analysis. This approach can be useful for hydrogen analysis in an accident related to hydrogen released into a containment building. In this study, CFD preliminary analysis has been performed to obtain the detailed information of the reactor containment building by using the CFD analysis techniques and to ensure that such information can be obtained via CFD analysis. We confirmed that CFD analysis can offer enough detailed information about flow patterns and temperature field and that CFD technique is a useful tool for HVAC design of nuclear power plants.

  6. Preliminary hazard analysis for the Brayton Isotope Ground Demonstration System (including vacuum test chamber)

    International Nuclear Information System (INIS)

    Miller, L.G.

    1975-01-01

    The Preliminary Hazard Analysis (PHA) of the BIPS-GDS is a tabular summary of hazards and undesired events which may lead to system damage or failure and/or hazard to personnel. The PHA reviews the GDS as it is envisioned to operate in the Vacuum Test Chamber (VTC) of the GDS Test Facility. The VTC and other equipment which will comprise the test facility are presently in an early stage of preliminary design and will undoubtedly undergo numerous changes before the design is frozen. The PHA and the FMECA to follow are intended to aid the design effort by identifying areas of concern which are critical to the safety and reliability of the BIPS-GDS and test facility

  7. Expression, purification, crystallization and preliminary crystallographic analysis of the proliferation-associated protein Ebp1

    International Nuclear Information System (INIS)

    Kowalinski, Eva; Bange, Gert; Wild, Klemens; Sinning, Irmgard

    2007-01-01

    Preliminary X-ray analysis of the proliferation-associated protein Ebp1 from Homo sapiens is provided. ErbB-3-binding protein 1 (Ebp1) is a member of the family of proliferation-associated 2G4 proteins (PA2G4s) and plays a role in cellular growth and differentiation. Ligand-induced activation of the transmembrane receptor ErbB3 leads to dissociation of Ebp1 from the receptor in a phosphorylation-dependent manner. The non-associated protein is involved in transcriptional and translational regulation in the cell. Here, the overexpression, purification, crystallization and preliminary crystallographic studies of Ebp1 from Homo sapiens are reported. Initially observed crystals were improved by serial seeding to single crystals suitable for data collection. The optimized crystals belong to the tetragonal space group P4 1 2 1 2 or P4 3 2 1 2 and diffracted to a resolution of 1.6 Å

  8. Most significant preliminary results of the probabilistic safety analysis on the Juragua nuclear power plant

    International Nuclear Information System (INIS)

    Perdomo, Manuel

    1995-01-01

    Since 1990 the Group for PSA Development and Applications (GDA/APS) is working on the Level-1 PSA for the Juragua-1 NPP, as a part of an IAEA Technical Assistance Project. The main objective of this study, which is still under way, is to assess, in a preliminary way, the Reactor design safety to find its potential 'weak points' at the construction stage, using a eneric data base. At the same time, the study allows the PSA team to familiarize with the plant design and analysis techniques for the future operational PSA of the plant. This paper presents the most significant preliminary results of the study, which reveal some advantages of the safety characteristics of the plant design in comparison with the homologous VVER-440 reactors and some areas, where including slight modifications would improve the plant safety, considering the level of detail at which the study is carried out. (author). 13 refs, 1 fig, 2 tabs

  9. Statistical analysis for the radiological characterization of radioactive waste in particle accelerators

    CERN Document Server

    AUTHOR|(CDS)2085595; Luccioni, Catherine

    This thesis introduces a new method to characterize metallic very-low-level radioactive waste produced at the European Organization for Nuclear Research (CERN). The method is based on: 1. the calculation of a preliminary radionuclide inventory, which is the list of the radionuclides that can be produced when particles interact with a surrounding medium, 2. the direct measurement of γ emitters and, 3. the quantification of pure-α, pure-β and low-energy X-ray emitters, called difficult-to-measure (DTM) radionuclides, using the so-called scaling factor (SF), correlation factor (CF) and mean activity (MA) techniques. The first stage of the characterization process is the calculation of the radionuclide inventory via either analytical or Monte Carlo codes. Once the preliminary radionuclide inventory is obtained, the γ-emitting radionuclides are measured via γ-ray spectrometry on each package of the waste population. The major γ-emitter, called key nuclide (KN), is also identified. The scaling factor method e...

  10. Radiological protection in interventional radiology

    International Nuclear Information System (INIS)

    Padovani, R.

    2001-01-01

    Interventional radiology (IR) reduces the need for many traditional interventions, particularly surgery, so reducing the discomfort and risk for patients compared with traditional systems. IR procedures are frequently performed by non-radiologist physicians, often without the proper radiological equipment and sufficient knowledge of radiation protection. Levels of doses to patients and staff in IR vary enormously. A poor correlation exists between patient and staff dose, and large variations of dose are reported for the same procedure. The occurrence of deterministic effects in patients is another peculiar aspect of IR owing to the potentially high skin doses of some procedures. The paper reviews the use of IR and the radiological protection of patients and staff, and examines the need for new standards for IR equipment and the training of personnel. (author)

  11. Management of radiological related equipments. Creating the equipment management database and analysis of the repair and maintenance records

    International Nuclear Information System (INIS)

    Eguchi, Megumu; Taguchi, Keiichi; Oota, Takashi; Kajiwara, Hiroki; Ono, Kiyotune; Hagio, Kiyofumi; Uesugi, Ekizo; Kajishima, Tetuo; Ueda, Kenji

    2002-01-01

    In 1997, we established the committee of equipments maintenance and management in our department. We designed the database in order to classify and register all the radiological related equipments using Microsoft Access. The management of conditions and cost of each equipment has become easier, by keeping and recording the database in the equipments management ledger and by filing the history of repairs or maintenances occurred to modalities. We then accounted numbers, cost of repairs and downtimes from the data of the repair and maintenance records for four years, and we reexamined the causal analysis of failures and the contents of the regular maintenance for CT and MRI equipments that had shown the higher numbers of repairs. Consequently, we have found the improvement of registration method of the data and the more economical way to use of the cost of repair. (author)

  12. Pediatric radiology

    International Nuclear Information System (INIS)

    Benz-Bohm, G.

    1997-01-01

    Pediatric radiology is an important subsection of diagnostic radiology involving specific difficulties, but unfortunately is quite too often neglected as a subject of further education and training. The book therefore is not intended for specialists in the field, but for radiologists wishing to plunge deeper into the matter of pediatric radiology and to acquire a sound, basic knowledge and information about well-proven modalities, the resulting diagnostic images, and interpretation of results. The book is a compact guide and a helpful source of reference and information required for every-day work, or in special cases. With patients who are babies or children, the challenges are different. The book offers all the information needed, including important experience from pediatric hospital units that may be helpful in diagnostic evaluation, information about specific dissimilarities in anatomy and physiology which affect the imaging results, hints for radiology planning and performance, as well as information about the various techniques and their indication and achievements. The book presents a wide spectrum of informative and annotated images. (orig./CB) [de

  13. Radiologic considerations

    International Nuclear Information System (INIS)

    Judge, L.O.

    1987-01-01

    An increasing variety of imaging modalities as well as refinements of interventional techniques have led to a resurgence of radiologic interest and participation in urolithiasis management. Judicious selection of the diagnostic examination, close monitoring during the procedure, consultation with urologic colleagues, and a careful regard for radiation safety guidelines define the role of the radiologist in renal stone disease

  14. Clinical and radiological analysis on the double contrast arthrography of the knee

    International Nuclear Information System (INIS)

    Sol, Chang Hyo; Lee, Suck Hong; Moon, Tae Yong; Kim, Byung Soo

    1980-01-01

    The author has performed double contrast arthrography of knee in 96 cases at Busan National University Hospital for about 4 years from May 1976 to April 1980. The 31 cases of them were analyzed both clinically and radiographycally with the background of definite diagnosis confirmed by operation. The results are as follows. 1. Of the 31 cases, 25 cases were male (80.6%), and 6 cases were female (19.4%). Male exceeded female in ratio of 5 : 1. 2. 22 cases (70.1%) were distributed from 15 to 26 years of age. 3. The left knee joint was a more prevalent site. The ratio of left to right was 16 : 14. One case was bilateral. 4. In 17 cases (45.2%) of the 31 cases, there was a positive history of trauma. 14 cases had no specific history (54.8%). 5. The operative findings showed lateral meniscus lesion in 25 cases (80.6%): medical meniscus lesion in 2 cases (6.5%); discoid meniscus in 2 cases (6.5%); lateral menisectomy in 1 cases (3.2%); and lateral meniscus lesion with medial collateral ligament tearing in 1 case (3.2%). 6. In 25 cases of the 31 cases, the radiologic abnormal findings corresponded to the operative findings. 5 cases revealed somewhat different features with the operative findings. One case which showed no abnormal roentgenographic findings was found to have abnormality at operation. As a result, the diagnostic accuracy of arthrography was 96.8%

  15. A radiologic analysis and comparative evaluation of hysterosalpingographic and laparoscopic findings in infertile patients

    International Nuclear Information System (INIS)

    Lee, Hang Young; Kim, Soo Won; Chung, Hye Kyung; Yu, Yun Jeong

    1984-01-01

    Hystreosalpingogram of 375 patients with infertility were reviewed with reference to radiological feature of each pathology and a comparative study of hysterosalpingography and laparoscopy in 36 patients was presented. This results were as follows;1. In 375 cases of infertility, 191 cases (50.9%) were primary infertility and 181 cases (49.1%) were secondary infertility. 2. The peak age distribution was 26 to 30 year old group in 211 cases (56.3%), and the peak duration of infertility was less than 3 years in 256 cases (68.3%). 3. Abnormal uterine findings were 115 cases (30.7%) and there were 73 cases of filling defects, 13 cases of irregularity, 12 cases of uterine flexion, 11 cases of congenital anomaly, and 9 cases of hypoplasia among them. 4. Abnormal tubal findings were 196 cases (52.3%) and there were 103 cases of simple obstruction, 69 cases of hydrosalpinx, and 50 cases of peritubal adhesion among them. 5. Intravasation of contrast media was noted in 42 cases (11.2%). 6. In 36 cases of laparoscopy, 23 cases (63.7%) was agreed to hysterosalpingography. 7. Although laparoscopy was better than hysterosalpingography in external anatomy of salpinx and relationship to ovary, hysterosalpingography should be important for fundamental study of infertile women because of lower failure rate, lower risk of complications, therapeutic effect, and lower cost.

  16. Analysis and assessment of the detriment in interventional radiology using biological dosimetry methods

    International Nuclear Information System (INIS)

    Montoro, A.; Almonacid, M.; Villaescusa, J.I.; Barquinero, J.F.; Rodriguez, P.; Barrios, L.; Verdu, G.; Ramos, M.

    2006-01-01

    Interventional radiologist and staff members usually are exposed to high levels of scattered radiation. As a result, the exposition to radiation procedures can produce detrimental effects that we would have to know. Effective dose is the quantity that better estimates the radiation risk. For this study we have realized an estimation of the radiological detriment to exposed workers of the Hospital la Fe de Valencia. For it, have been used physical doses registered in detectors T.L.D., and doses estimated by biological dosimetry in lymphocytes of peripheral blood. There has been estimated for every case the probability of effect of skin cancer and of non-solid cancers (leukaemia, lymphoma and myeloma), being compared with the baseline probability of natural effect. Biological doses were obtained by extrapolating the yield of dicentrics and translocations to their respective dose -effect curves. The discrepancies observed between physically recorded doses and biological estimated doses indicate that workers did not always wear their dosimeters or the dosimeters were not always in the radiation field. Cytogenetic studies should be extended to more workers to assess the risk derived from their occupational exposure. (authors)

  17. Mechanical analysis of flying robot for nuclear safety and security control by radiological monitoring

    International Nuclear Information System (INIS)

    Cho, Hyo Sung; Woo, Tae Ho

    2016-01-01

    Highlights: • Radiological monitoring of the NPPs site is performed by the flying robot. • The mechanics of drone is investigated in the NPPs. • Yaw and Pitch motions are simulated for the robotic behaviors. • The flying robot is analyzed for the nuclear safety and security successfully. - Abstract: The flying robot is investigated for the nuclear accident and security treatment. Several mechanics are introduced for the movement of the drone. The optimized motion of the drone should cover all areas of Nuclear Power Plants (NPPs) over the site where the circular and surmounting motions are needed with traverse of zigzag shapes. There is the Yaw motion in the circular moving and the Pitch motion in the climbing and downing against reactor facility. The fallout is calculated from the radiation concentration in the breaking part of the NPPs where the radioactive material leaks from the containment, coolant loop, plant facility and so on. The dose equivalents are obtained where the values are changeable following the random values of the y value, average wind speed, and dispersed concentration in the detection position. The simulation of new positions of x, y, and z are normalized from 0.0 to 1.0. The mechanics of flying robot produces the multidisciplinary converged technology incorporated with the aerial radiation monitoring information.

  18. Analysis and assessment of the detriment in interventional radiology using biological dosimetry methods

    Energy Technology Data Exchange (ETDEWEB)

    Montoro, A.; Almonacid, M.; Villaescusa, J.I. [Hospital Univ. la Fe de Valen cian, Servicio de Proteccion Radiologica, Valencia (Spain); Barquinero, J.F.; Rodriguez, P. [Universitat Autonom a de Barcelona, Servicio de Dosimetria Biologica, Unidad de Antropologia, Departamento de Biologia Animal, Vegetal y Ecologia., Barcelona (Spain); Barrios, L. [Universidad Autonoma de Barcelona, Dept. de Biologia Celular y Fisiologia. Unidad de Biologia Celular, Barcelona (Spain); Verdu, G.; Ramos, M. [Universidad Politecnica de Valencia, Dept. de Ingenieria Quimica y Nuclear, Valencia, (Spain)

    2006-07-01

    Interventional radiologist and staff members usually are exposed to high levels of scattered radiation. As a result, the exposition to radiation procedures can produce detrimental effects that we would have to know. Effective dose is the quantity that better estimates the radiation risk. For this study we have realized an estimation of the radiological detriment to exposed workers of the Hospital la Fe de Valencia. For it, have been used physical doses registered in detectors T.L.D., and doses estimated by biological dosimetry in lymphocytes of peripheral blood. There has been estimated for every case the probability of effect of skin cancer and of non-solid cancers (leukaemia, lymphoma and myeloma), being compared with the baseline probability of natural effect. Biological doses were obtained by extrapolating the yield of dicentrics and translocations to their respective dose -effect curves. The discrepancies observed between physically recorded doses and biological estimated doses indicate that workers did not always wear their dosimeters or the dosimeters were not always in the radiation field. Cytogenetic studies should be extended to more workers to assess the risk derived from their occupational exposure. (authors)

  19. Radiology of chest diseases

    International Nuclear Information System (INIS)

    Lange, S.; Stark, P.

    1990-01-01

    This book is divided into three parts: The first part - 'Technology and normal findings' - explains current radiological diagnostic methods. The indications for particular examinations are given, with the techniques and possible errors. The second part of the book - 'Diseases of the lung' - gives a systematic description of basic knowledge needed for diagnosis. Each chapter begins with a definition of the disease and a discussion of the diagnostic information that can be expected from the various radiological methods. This is followed by the pathological morphology and pathological physiology and the clinical symptoms. The third part of the book - 'Radiological signs and differential diagnosis' - deals with image patterns, such as segmental opacities, calcification, localized hyperlucency, etc. It begins where the diagnostician must begin - immediate confrontation with the radiograph, analysis of the details, recognition of structures and understanding the image. (orig./DGD) With 381 figs., 42 tabs

  20. Preliminary design and off-design performance analysis of an Organic Rankine Cycle for geothermal sources

    International Nuclear Information System (INIS)

    Hu, Dongshuai; Li, Saili; Zheng, Ya; Wang, Jiangfeng; Dai, Yiping

    2015-01-01

    Highlights: • A method for preliminary design and performance prediction is established. • Preliminary data of radial inflow turbine and plate heat exchanger are obtained. • Off-design performance curves of critical components are researched. • Performance maps in sliding pressure operation are illustrated. - Abstract: Geothermal fluid of 90 °C and 10 kg/s can be exploited together with oil in Huabei Oilfield of China. Organic Rankine Cycle is regarded as a reasonable method to utilize these geothermal sources. This study conducts a detailed design and off-design performance analysis based on the preliminary design of turbines and heat exchangers. The radial inflow turbine and plate heat exchanger are selected in this paper. Sliding pressure operation is applied in the simulation and three parameters are considered: geothermal fluid mass flow rate, geothermal fluid temperature and condensing pressure. The results indicate that in all considered conditions the designed radial inflow turbine has smooth off-design performance and no choke or supersonic flow are found at the nozzle and rotor exit. The lager geothermal fluid mass flow rate, the higher geothermal fluid temperature and the lower condensing pressure contribute to the increase of cycle efficiency and net power. Performance maps are illustrated to make system meet different load requirements especially when the geothermal fluid temperature and condensing pressure deviate from the design condition. This model can be used to provide basic data for future detailed design, and predict off-design performance in the initial design phase