WorldWideScience

Sample records for preliminary operational guidelines

  1. Preliminary report on operational guidelines developed for use in emergency preparedness and response to a radiological dispersal device incident.

    Energy Technology Data Exchange (ETDEWEB)

    Yu, C.; Cheng, J.-J.; Kamboj, S.; Domotor, S.; Wallo, A.; Environmental Science Division; DOE

    2006-12-15

    This report presents preliminary operational guidelines and supporting work products developed through the interagency Operational Guidelines Task Group (OGT). The report consolidates preliminary operational guidelines, all ancillary work products, and a companion software tool that facilitates their implementation into one reference source document. The report is intended for interim use and comment and provides the foundation for fostering future reviews of the operational guidelines and their implementation within emergency preparedness and response initiatives in the event of a radiological dispersal device (RDD) incident. The report principally focuses on the technical derivation and presentation of the operational guidelines. End-user guidance providing more details on how to apply these operational guidelines within planning and response settings is being considered and developed elsewhere. The preliminary operational guidelines are categorized into seven groups on the basis of their intended application within early, intermediate, and long-term recovery phases of emergency response. We anticipate that these operational guidelines will be updated and refined by interested government agencies in response to comments and lessons learned from their review, consideration, and trial application. This review, comment, and trial application process will facilitate the selection of a final set of operational guidelines that may be more or less inclusive of the preliminary operational guidelines presented in this report. These and updated versions of the operational guidelines will be made available through the OGT public Web site (http://ogcms.energy.gov) as they become finalized for public distribution and comment.

  2. Dam safety operating guidelines

    International Nuclear Information System (INIS)

    Elsayed, E.; Leung, T.; Kirkham, A.; Lum, D.

    1990-01-01

    As part of Ontario Hydro's dam structure assessment program, the hydraulic design review of several river systems has revealed that many existing dam sites, under current operating procedures, would not have sufficient discharge capacity to pass the Inflow Design Flood (IDF) without compromising the integrity of the associated structures. Typical mitigative measures usually considered in dealing with these dam sites include structural alterations, emergency action plans and/or special operating procedures designed for extreme floods. A pilot study was carried out for the Madawaska River system in eastern Ontario, which has seven Ontario Hydro dam sites in series, to develop and evaluate the effectiveness of the Dam Safety Operating Guidelines (DSOG). The DSOG consist of two components: the flood routing schedules and the minimum discharge schedules, the former of which would apply in the case of severe spring flood conditions when the maximum observed snowpack water content and the forecast rainfall depth exceed threshold values. The flood routing schedules would identify to the operator the optimal timing and/or extent of utilizing the discharge facilities at each dam site to minimize the potential for dam failures cased by overtopping anywhere in the system. It was found that the DSOG reduced the number of structures overtopped during probable maximum flood from thirteen to four, while the number of structures that could fail would be reduced from seven to two. 8 refs., 4 figs., 3 tabs

  3. Utilizing the ECHO Model in the Veterans Health Affairs System: Guidelines for Setup, Operations and Preliminary Findings

    Directory of Open Access Journals (Sweden)

    Herschel Knapp

    2015-06-01

    Full Text Available Background: In 2011, the Veterans Health Administration (VHA consulted with the Project ECHO (Extension for Community Healthcare Outcomes team at the University of New Mexico, Albuquerque, to reproduce their successful model within the VHA. Methods: The VHA launched SCAN-ECHO (Specialty Care Access Network-Extension for Community Healthcare Outcomes, a multisite videoconferencing system to conduct live clinical consultations between specialists at a VHA Medical Center (hospital and primary care providers stationed at satellite VHA CBOCs (Community-Based Outpatient Clinic. Results: Analysis of the first three years rendered a mean attendee satisfaction of 89.53% and a consultation satisfaction score of 88.10%. About half of the SCAN-ECHO consultations resulted in patients receiving their treatment from their local primary care providers; the remaining half were referred to the VHA Medical Center when the treatment involved equipment or services not available at the CBOCs (e.g., MRI, surgery. Conclusion: This paper details the setup, operation logistics and preliminary findings, suggesting that SCAN-ECHO is a viable model for providing quality specialty clinical consultation service, prompter access to care, reduced commutes and continuing education. Additionally, the use of a secured Internet-based videoconferencing system that supports connectivity to multiple (mobile devices could expand the utilization of this service.

  4. No. 148-Guidelines for Operative Vaginal Birth.

    Science.gov (United States)

    Cargill, Yvonne M; MacKinnon, Catherine Jane

    2018-02-01

    To provide guidelines for operative vaginal birth in the management of the second stage of labour. Non-operative techniques, episiotomy, and Caesarean section are compared to operative vaginal birth. Reduced fetal and maternal morbidity and mortality. MEDLINE and Cochrane databases were searched using the key words ''vacuum" and "birth" as well as "forceps" and "birth" for literature published in English from january 1970 to June 2004. The level of evidence and quality of rec-ommendations made are described using the Evaluation of Evidence from the Canadian Task Force on the Periodic Health Examination. VALIDATION: The Clinical Practice Obstetrics Committee and Executive and Council of the Society of Obstetricians and Gynaecologists of Canada approved these guidelines. Copyright © 2018. Published by Elsevier Inc.

  5. 50 CFR 253.18 - Program operating guidelines.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Program operating guidelines. 253.18 Section 253.18 Wildlife and Fisheries NATIONAL MARINE FISHERIES SERVICE, NATIONAL OCEANIC AND ATMOSPHERIC... Guarantee Program § 253.18 Program operating guidelines. The Division may issue Program operating guidelines...

  6. Operating Plan and Guidelines (2011 - 2016)

    International Nuclear Information System (INIS)

    2011-01-01

    The Committee on Nuclear Regulatory Activities (CNRA) of the OECD Nuclear Energy Agency (NEA) is an international committee made up primarily of senior nuclear regulators. It was established in 1989 as a forum for the exchange of information and experience among regulatory organisations and for the review of developments which could affect regulatory requirements. The Committee is responsible for the programme of the NEA, concerning the regulation, licensing and inspection of nuclear installations. In particular, the Committee reviews current practices and operating experience. The Joint CSNI/CNRA Strategic Plan states that: The Operating Plan for each committee aligns with the Joint CNRA/ CSNI Strategic Plan. The Committee's Operating Plans describes each Committee's organisation, priorities, and operating procedures to be used in fulfilling their mandates in accordance with this strategic plan. Specific attention will be given to ensure that cross-cutting issues are satisfactorily dealt with. This report represents such an operating plan. The intention is that it should fit onto a new third rung on the ladder representing the hierarchy of documents that govern the work of CNRA. At the top of this hierarchy is the Strategic Plan of the NEA; immediately below that is the Joint CSNI/CNRA Strategic Plan; followed by the new operating plan and the guidelines for methods of work. This plan sets the basis for establishing the current CNRA Programme of Work. Since the issuance of the last plan in 2007 there has been a significant shift and many member countries are now constructing new facilities or in the process of legislative or technical processing for new licenses. This comes along in an atmosphere in which current operating plants requesting power up-rates, extended licenses, and substantial activity in new licensing and new construction. It is clear that all these activities require similar attention from the regulators and operators, and the responsibilities

  7. Influence of Planetary Protection Guidelines on Waste Management Operations

    Science.gov (United States)

    Hogan, John A.; Fisher, John W.; Levri, Julie A.; Wignarajah, Kanapathipi; Race, Margaret S.; Stabekis, Perry D.; Rummel, John D.

    2005-01-01

    Newly outlined missions in the Space Exploration Initiative include extended human habitation on Mars. During these missions, large amounts of waste materials will be generated in solid, liquid and gaseous form. Returning these wastes to Earth will be extremely costly, and will therefore likely remain on Mars. Untreated, these wastes are a reservoir of live/dead organisms and molecules considered to be "biomarkers" i.e., indicators of life). If released to the planetary surface, these materials can potentially confound exobiology experiments and disrupt Martian ecology indefinitely (if existent). Waste management systems must therefore be specifically designed to control release of problematic materials both during the active phase of the mission, and for any specified post-mission duration. To effectively develop waste management requirements for Mars missions, planetary protection guidelines must first be established. While previous policies for Apollo lunar missions exist, it is anticipated that the increased probability of finding evidence of life on Mars, as well as the lengthy mission durations will initially lead to more conservative planetary protection measures. To facilitate the development of overall requirements for both waste management and planetary protection for future missions, a workshop was conducted to identify how these two areas interface, and to establish a preliminary set of planetary protection guidelines that address waste management operations. This paper provides background regarding past and current planetary protection and waste management issues, and their interactions. A summary of the recommended planetary protection guidelines, anticipated ramifications and research needs for waste management system design for both forward (Mars) and backward (Earth) contamination is also provided.

  8. Guideline for the preparation of safe operating procedures

    International Nuclear Information System (INIS)

    Stinnett, L.; Armbrust, E.F.; Christy, V.W.; Doyle, J.R.; Kesinger, J.H.

    1977-03-01

    Sandia Laboratories Safe Operating Procedures (SOP) are written for activities which involve the use of explosives, dangerous chemicals, radioactive materials, hazardous systems, and certain types of operational facilities which present hazards. This guideline presents a suggested SOP format

  9. Guideline for the preparation of safe operating procedures

    International Nuclear Information System (INIS)

    Stinnett, L.; Carroll, M.M.; Crooks, D.L.; Doyle, J.R.; Jeblick, H.G.; Kessel, D.S.; Tippy, M.W.; Stuckey, J.M.

    1981-03-01

    These procedures are written for activities that involve the use of explosives, dangerous chemicals, radioactive materials, hazardous sytems, and for certain types of operational facilities which present hazards. This guideline presents a suggested Safe Operating Procedures format

  10. Main-coolant-pump shaft-seal guidelines. Volume 2. Operational guidelines. Final report

    International Nuclear Information System (INIS)

    Fair, C.E.; Greer, A.O.

    1983-03-01

    This report presents a set of guidelines and criteria for improving main coolant pump shaft seal operational reliability. The noted guidelines are developed from EPRI sponsored nuclear power plant seal operating experience studies. Usage procedures/practices and operational environment influence on seal life and reliability from the most recent such survey are summarized. The shaft seal and its auxiliary supporting systems are discussed both from technical and operational related viewpoints

  11. General Guidelines for Remote Operation and Maintenance of Pyroprocess Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S. H.; Park, B. S.; Park, H. S.; Lee, H. J.; Choi, C. W.; Lee, J. K

    2007-12-15

    As the pyroprocess handle the high radioactive materials, a high radioactive material handling facility required high safety, radioactive shielding, strict quality control, and the remote handling equipment of high technology. This report describes the guidelines of for pyroprocess based the design guides for radioactive material handling facility and equipment from American Nuclear Society(ANS), design guidelines for remotely maintained equipment from Oak Ridge National Laboratory(ORNL), and the experience of design for ACP equipment installed at the ACPF(Advanced Conditioning Process Facility). The General guidelines in this report are as follows. The General guidelines for remote operation and maintenance of pyroprocess equipment: Pyroprocess, Remote handling equipment for pyroprocess, General guide for remote operation and maintenance, general guidelines for the design of remotely operated and maintained equipment, Estimation and analysis for remote maintenance.

  12. Autonomous Operations Design Guidelines for Flight Hardware

    Data.gov (United States)

    National Aeronautics and Space Administration — SSC experimentally modified an autonomous operations flexible system suite developed for a ground application for a flight system under development by JSC. The...

  13. The European Stroke Organisation Guidelines: a standard operating procedure.

    Science.gov (United States)

    Ntaios, George; Bornstein, Natan M; Caso, Valeria; Christensen, Hanne; De Keyser, Jacques; Diener, Hans-Christoph; Diez-Tejedor, Exuperio; Ferro, Jose M; Ford, Gary A; Grau, Armin; Keller, Emanuella; Leys, Didier; Russell, David; Toni, Danilo; Turc, Guillaume; Van der Worp, Bart; Wahlgren, Nils; Steiner, Thorsten

    2015-10-01

    In 2008, the recently founded European Stroke Organisation published its guidelines for the management of ischemic stroke and transient ischemic attack. This highly cited document was translated in several languages and was updated in 2009. Since then, the European Stroke Organisation has published guidelines for the management of intracranial aneurysms and subarachnoidal hemorrhage, for the establishment of stroke units and stroke centers, and recently for the management of intracerebral hemorrhage. In recent years, the methodology for the development of guidelines has evolved significantly. To keep pace with this progress and driven by the strong determination of the European Stroke Organisation to further promote stroke management, education, and research, the European Stroke Organisation decided to delineate a detailed standard operating procedure for its guidelines. There are two important cornerstones in this standard operating procedure: The first is the implementation of the Grading of Recommendations Assessment, Development, and Evaluation methodology for the development of its Guideline Documents. The second one is the decision of the European Stroke Organisation to move from the classical model of a single Guideline Document about a major topic (e.g. management of ischemic stroke) to focused modules (i.e. subdivisions of a major topic). This will enable the European Stroke Organisation to react faster when new developments in a specific stroke field occur and update its recommendations on the related module rather swiftly; with the previous approach of a single large Guideline Document, its entire revision had to be completed before an updated publication, delaying the production of up-to-date guidelines. After discussion within the European Stroke Organisation Guidelines Committee and significant input from European Stroke Organisation members as well as methodologists and analysts, this document presents the official standard operating procedure for

  14. Pre-operative fasting guidelines: an update

    DEFF Research Database (Denmark)

    Søreide, E; Eriksson, L I; Hirlekar, G

    2005-01-01

    Liberal pre-operative fasting routines have been implemented in most countries. In general, clear fluids are allowed up to 2 h before anaesthesia, and light meals up to 6 h. The same recommendations apply for children and pregnant women not in labour. In children......Liberal pre-operative fasting routines have been implemented in most countries. In general, clear fluids are allowed up to 2 h before anaesthesia, and light meals up to 6 h. The same recommendations apply for children and pregnant women not in labour. In children...

  15. Guidelines for safe process operations and maintenance

    CERN Document Server

    2010-01-01

    First-line managers have to maintain the integrity of facilities, control manufacturing processes, and handle unusual or emergency situations, as well as respond to the pressures of production demand. On a daily basis, they are closest to the operating personnel who may be injured by a process accident, and they are in the best position to spot problem conditions and to act to contain them. This book offers these managers ""how-to"" information on process safety management program execution in the operations and maintenance departments, recommending technical and administrative process safety

  16. Digital Skill Training Research: Preliminary Guidelines for Distributed Learning

    National Research Council Canada - National Science Library

    Childs, Jerry

    2001-01-01

    This task was aimed at the development of guidelines for distributed learning (DL). A matrix was generated to evaluate the effectiveness of various DL media for training representative knowledge/skill types...

  17. Standard operating procedures for ESPEN guidelines and consensus papers.

    Science.gov (United States)

    Bischoff, Stephan C; Singer, Pierre; Koller, Michael; Barazzoni, Rocco; Cederholm, Tommy; van Gossum, André

    2015-12-01

    The ESPEN Guideline standard operating procedures (SOP) is based on the methodology provided by the Association of Scientific Medical Societies of Germany (AWMF), the Scottish Intercollegiate Guidelines Network (SIGN), and the Centre for Evidence-based Medicine at the University of Oxford. The SOP is valid and obligatory for all future ESPEN-sponsored guideline projects aiming to generate high-quality guidelines on a regular basis. The SOP aims to facilitate the preparation of guideline projects, to streamline the consensus process, to ensure quality and transparency, and to facilitate the dissemination and publication of ESPEN guidelines. To achieve this goal, the ESPEN Guidelines Editorial board (GEB) has been established headed by two chairmen. The GEB will support and supervise the guideline processes and is responsible for the strategic planning of ESPEN guideline activities. Key elements of the SOP are the generation of well-built clinical questions according to the PICO system, a systemic literature search, a classification of the selected literature according to the SIGN evidence levels providing an evidence table, and a clear and straight-forward consensus procedure consisting of online voting's and a consensus conference. Only experts who meet the obligation to disclosure any potential conflict of interests and who are not employed by the Industry can participate in the guideline process. All recommendations will be graded according to the SIGN grading and novel outcome models besides biomedical endpoints. This approach will further extent the leadership of ESPEN in creating up-to-date and suitable for implementation guidelines and in sharing knowledge on malnutrition and clinical nutrition. Copyright © 2015 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  18. The European Stroke Organisation Guidelines: a standard operating procedure

    DEFF Research Database (Denmark)

    Ntaios, George; Bornstein, Natan M; Caso, Valeria

    2015-01-01

    pace with this progress and driven by the strong determination of the European Stroke Organisation to further promote stroke management, education, and research, the European Stroke Organisation decided to delineate a detailed standard operating procedure for its guidelines. There are two important...... cornerstones in this standard operating procedure: The first is the implementation of the Grading of Recommendations Assessment, Development, and Evaluation methodology for the development of its Guideline Documents. The second one is the decision of the European Stroke Organisation to move from the classical...... and significant input from European Stroke Organisation members as well as methodologists and analysts, this document presents the official standard operating procedure for the development of the Guideline Documents of the European Stroke Organisation....

  19. National synchrotron light source guidelines for the conduct of operations

    International Nuclear Information System (INIS)

    Buckley, M.

    1998-01-01

    To improve the quality and uniformity of operations at the Department of Energy's facilities, the DOE issued Order 5480.19 ''Conduct of Operations Requirements at DOE facilities.'' This order recognizes that the success of a facility's mission critically depends upon a high level of performance by its personnel and equipment. This performance can be severely impaired if the facility's Conduct of Operations pays inadequate attention to issues of organization, safety, health, and the environment. These guidelines are Brookhaven National Laboratory's and the National Synchrotron Light Source's acknowledgement of the principles of Conduct of Operations and the response to DOE Order 5480.19. These guidelines cover the following areas: (1) operations organization and administration; (2) shift routines and operating practices; (3) control area activities; (4) communications; (5) control of on-shift training; (6) investigation of abnormal events; (7) notifications; (8) control of equipment and system studies; (9) lockouts and tagouts; (10) independent verification; (11) log-keeping; (12) operations turnover; (13) operations aspects of facility process control (14) required reading; (15) timely orders to operators; (16) operations procedures; (17) operator aid posting; and (18) equipment sizing and labeling

  20. 78 FR 48159 - Preliminary 2012 Effluent Guidelines Program Plan and 2011 Annual Effluent Guidelines Review Report

    Science.gov (United States)

    2013-08-07

    ... publish a preliminary plan in the odd numbered years and a final plan in the even numbered years. The... necessary before concluding the review of the three remaining point source categories: Pulp, Paper and... standards for the 2012 reviews. These methodologies included: Identifying pass-through pollutants in sewage...

  1. Standing operating procedures for developing acute exposure guideline levels for hazardous chemicals

    National Research Council Canada - National Science Library

    National Research Council (U.S.). Subcommittee on Acute Exposure Guideline Levels

    2001-01-01

    Standing Operating Procedures for Developing Acute Exposure Guideline Levels for Hazardous Chemicals contains a detailed and comprehensive methodology for developing acute exposure guideline levels (AEGLs...

  2. Improving operation notes to meet British Orthopaedic Association guidelines.

    Science.gov (United States)

    Morgan, David; Fisher, Noel; Ahmad, Aman; Alam, Fazle

    2009-04-01

    Operation notes are an important part of medical records for clinical, academic and medicolegal reasons. This study audited the quality of operative note keeping for total knee replacements against the standards set by the British Orthopaedic Association (BOA). A prospective review of all patients undergoing total knee replacement at a district general hospital over 8 months. Data recorded were compared with those required by the BOA good-practice guidelines. Change in practice was implemented and the audit cycle completed. Data were statistically analysed. A total of 129 operation notes were reviewed. There was a significant improvement in the mean number of data points recorded from 9.6 to 13.1. The least well recorded data were diagnosis, description of findings, alignment and postoperative flexion range. All had a significant improvement except description of findings. The operating surgeon writing the note improved from 56% to 67%. Detailed postoperative instructions also improved in quality. Surgeon education and the use of a checklist produce better quality total knee replacement operation notes in line with BOA guidelines. Further improvements may be made by making the data points part of the operation note itself.

  3. Criteria for safety-related nuclear plant operator actions: a preliminary assessment of available data

    International Nuclear Information System (INIS)

    Haas, P.M.; Bott, T.F.

    1980-01-01

    In the US, an effort has been underway for a number of years to develop a design standard to define when required manual operator action can be accepted as part of a nuclear plant design basis. Insufficient data are available to provide quantitative guidelines for the standard. To provide the necessary data base to support such standards and the necessary quantitative assessment of operator reliability, the US Nuclear Regulatory Commission is sponsoring a study at Oak National Laboratory to develop the data base. A preliminary assessment completed in April, 1979 concluded that sufficient data from US operating experience did not exist to provide an adequate data base. A program of research using full-scope nuclear plant simulators and results that are correlated to field data was suggested. That program was recently initiated. The approach, results and conclusions of the preliminary assessment are reviewed and the planned research program of simulator studies is summarised. (author)

  4. Role of operator response guidelines in CANDU 9 design program

    International Nuclear Information System (INIS)

    Jaitly, R.K.

    2000-01-01

    The CANDU 9 is a large version of the CANDU Pressurized Heavy Water Reactor (PHWR) system developed in Canada. With an electrical output of approximately 935 MWe, the CANDU 9 complements the established mid-size CANDU 6 (700 MWe) and makes use of proven technology updated with state of the art features resulting from ongoing development. The CANDU 9 builds on the reactor and process system designs of the operating Darlington and Bruce B plants, and incorporates a modified CANDU 6 station layout, as well as improved construction methods and operational features. A high level of standardization has always been a feature of CANDU reactors. This theme is emphasized in the CANDU 9; all key components (reactor core, steam generators, coolant pumps, pressure tubes, etc.) are of the same design as those proven in service in the operating CANDU power stations. Including Probabilistic Safety Assessment (PSA) as part of the CANDU 9 design process from the outset of the program was seen as key to ensuring completeness of safety related requirements. The PSA work provided an in-depth understanding of the plant response to various postulated accidents. As well, the time frame for recovery and the related operator actions were identified. This information together with AECL's experience in supporting the development of Emergency Operating Procedures (EOPs) for the operating CANDU reactors are the basis for preparation of CANDU 9 Operator Response Guidelines (ORGs). Technical content, format and human factors considerations adopted for the ORGs are such that these can be readily converted to EOPs. The scope of ORGs includes generic as well as event specific ORGs. This dual approach is required to provide defense-in-depth. This paper describes the process used to prepare ORGs for the CANDU 9 reactor and discusses important benefits gained from the application of ORGs as input to the control center design and future preparation of the EOPs. (author)

  5. Treatment Guidelines for Preoperative Radiation Therapy for Retroperitoneal Sarcoma: Preliminary Consensus of an International Expert Panel

    Energy Technology Data Exchange (ETDEWEB)

    Baldini, Elizabeth H., E-mail: ebaldini@partners.org [Department of Radiation Oncology, Dana-Farber Cancer Institute and Brigham and Women' s Hospital, Boston, Massachusetts (United States); Wang, Dian [Department of Radiation Oncology, Rush University Medical Center, Chicago, Illinois (United States); Haas, Rick L.M. [Department of Radiotherapy, The Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Catton, Charles N. [Department of Radiation Oncology, Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Indelicato, Daniel J. [Department of Radiation Oncology, University of Florida Medical Center, Jacksonville, Florida (United States); Kirsch, David G. [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Roberge, David [Department of Radiation Oncology, Centre Hospitalier de l' Université de Montreal, Montreal, Quebec (Canada); Salerno, Kilian [Department of Radiation Oncology, Roswell Park Cancer Institute, Buffalo, New York (United States); Deville, Curtiland [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Sidney Kimmel Cancer Center, Washington, DC (United States); Guadagnolo, B. Ashleigh [Department of Radiation Oncology, MD Anderson Cancer Center, Houston, Texas (United States); O' Sullivan, Brian [Department of Radiation Oncology, Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Petersen, Ivy A. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States); Le Pechoux, Cecile [Department of Radiotherapy, Institut Gustave-Roussy, Villejuif (France); Abrams, Ross A. [Department of Radiation Oncology, Rush University Medical Center, Chicago, Illinois (United States); DeLaney, Thomas F. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States)

    2015-07-01

    Purpose: Evidence for external beam radiation therapy (RT) as part of treatment for retroperitoneal sarcoma (RPS) is limited. Preoperative RT is the subject of a current randomized trial, but the results will not be available for many years. In the meantime, many practitioners use preoperative RT for RPS, and although this approach is used in practice, there are no radiation treatment guidelines. An international expert panel was convened to develop consensus treatment guidelines for preoperative RT for RPS. Methods and Materials: An expert panel of 15 academic radiation oncologists who specialize in the treatment of sarcoma was assembled. A systematic review of reports related to RT for RPS, RT for extremity sarcoma, and RT-related toxicities for organs at risk was performed. Due to the paucity of high-quality published data on the subject of RT for RPS, consensus recommendations were based largely on expert opinion derived from clinical experience and extrapolation of relevant published reports. It is intended that these clinical practice guidelines be updated as pertinent data become available. Results: Treatment guidelines for preoperative RT for RPS are presented. Conclusions: An international panel of radiation oncologists who specialize in sarcoma reached consensus guidelines for preoperative RT for RPS. Many of the recommendations are based on expert opinion because of the absence of higher level evidence and, thus, are best regarded as preliminary. We emphasize that the role of preoperative RT for RPS has not been proven, and we await data from the European Organization for Research and Treatment of Cancer (EORTC) study of preoperative radiotherapy plus surgery versus surgery alone for patients with RPS. Further data are also anticipated pertaining to normal tissue dose constraints, particularly for bowel tolerance. Nonetheless, as we await these data, the guidelines herein can be used to establish treatment uniformity to aid future assessments of efficacy

  6. Preliminary Analysis of Helicopter Options to Support Tunisian Counterterrorism Operations

    Science.gov (United States)

    2016-04-27

    helicopters from Sikorsky to fulfill a number of roles in counterterrorism operations. Rising costs and delays in delivery raised the question of...whether other cost-effective options exist to meet Tunisia’s helicopter requirement. Approach Our team conducted a preliminary assessment of...alternative helicopters for counterterrorism air assault missions. Any decision to acquire an aircraft must consider many factors, including technical

  7. Autonomous Aircraft Operations using RTCA Guidelines for Airborne Conflict Management

    Science.gov (United States)

    Krishnamurthy, Karthik; Wing, David J.; Barmore, Bryan E.; Barhydt, Richard; Palmer, Michael T.; Johnson, Edward J.; Ballin, Mark G.; Eischeid, Todd M.

    2003-01-01

    A human-in-the-loop experiment was performed at the NASA Langley Research Center to study the feasibility of DAG-TM autonomous aircraft operations in highly constrained airspace. The airspace was constrained by a pair of special-use airspace (SUA) regions on either side of the pilot's planned route. Traffic flow management (TFM) constraints were imposed as a required time of arrival and crossing altitude at an en route fix. Key guidelines from the RTCA Airborne Conflict Management (ACM) concept were applied to autonomous aircraft operations for this experiment. These concepts included the RTCA ACM definitions of distinct conflict detection and collision avoidance zones, and the use of a graded system of conflict alerts for the flight crew. Three studies were conducted in the course of the experiment. The first study investigated the effect of hazard proximity upon pilot ability to meet constraints and solve conflict situations. The second study investigated pilot use of the airborne tools when faced with an unexpected loss of separation (LOS). The third study explored pilot interactions in an over-constrained conflict situation, with and without priority rules dictating who should move first. Detailed results from these studies were presented at the 5th USA/Europe Air Traffic Management R&D Seminar (ATM2003). This overview paper focuses on the integration of the RTCA ACM concept into autonomous aircraft operations in highly constrained situations, and provides an overview of the results presented at the ATM2003 seminar. These results, together with previously reported studies, continue to support the feasibility of autonomous aircraft operations.

  8. Operational research on implementation of tuberculosis guidelines in Mozambique

    NARCIS (Netherlands)

    Brouwer, M.A.

    2015-01-01

    The overall objective of this thesis is to assess how guideline implementation and evaluation contribute to health care decision-making and to assess what critical factors contribute to successful or unsuccessful implementation of TB control guidelines through case studies mainly conducted in

  9. Operational Earthquake Forecasting: Proposed Guidelines for Implementation (Invited)

    Science.gov (United States)

    Jordan, T. H.

    2010-12-01

    The goal of operational earthquake forecasting (OEF) is to provide the public with authoritative information about how seismic hazards are changing with time. During periods of high seismic activity, short-term earthquake forecasts based on empirical statistical models can attain nominal probability gains in excess of 100 relative to the long-term forecasts used in probabilistic seismic hazard analysis (PSHA). Prospective experiments are underway by the Collaboratory for the Study of Earthquake Predictability (CSEP) to evaluate the reliability and skill of these seismicity-based forecasts in a variety of tectonic environments. How such information should be used for civil protection is by no means clear, because even with hundredfold increases, the probabilities of large earthquakes typically remain small, rarely exceeding a few percent over forecasting intervals of days or weeks. Civil protection agencies have been understandably cautious in implementing formal procedures for OEF in this sort of “low-probability environment.” Nevertheless, the need to move more quickly towards OEF has been underscored by recent experiences, such as the 2009 L’Aquila earthquake sequence and other seismic crises in which an anxious public has been confused by informal, inconsistent earthquake forecasts. Whether scientists like it or not, rising public expectations for real-time information, accelerated by the use of social media, will require civil protection agencies to develop sources of authoritative information about the short-term earthquake probabilities. In this presentation, I will discuss guidelines for the implementation of OEF informed by my experience on the California Earthquake Prediction Evaluation Council, convened by CalEMA, and the International Commission on Earthquake Forecasting, convened by the Italian government following the L’Aquila disaster. (a) Public sources of information on short-term probabilities should be authoritative, scientific, open, and

  10. Operating cost guidelines for benchmarking DOE thermal treatment systems for low-level mixed waste

    International Nuclear Information System (INIS)

    Salmon, R.; Loghry, S.L.; Hermes, W.H.

    1994-11-01

    This report presents guidelines for estimating operating costs for use in benchmarking US Department of Energy (DOE) low-level mixed waste thermal treatment systems. The guidelines are based on operating cost experience at the DOE Toxic Substances Control Act (TSCA) mixed waste incinerator at the K-25 Site at Oak Ridge. In presenting these guidelines, it should be made clear at the outset that it is not the intention of this report to present operating cost estimates for new technologies, but only guidelines for estimating such costs

  11. Commissioning and preliminary operation of HL-2A tokamak

    International Nuclear Information System (INIS)

    Liu Dequan; Liu Yong; Yan Jianchen; Cao Zeng; Yang Qingwei; Zhou Caipin; Li Xiaodong

    2005-01-01

    HL-2A is a divertor tokamak located at new site of Southwestern Institute of Physics (SWIP), Chengdu, China. It can be operated in double-null and single-null divertor with closed configurations. The effects of the divertor on impurity behaviors, MHD instabilities, transport, wall conditioning and divertor physics are key issues to be studied during the first step operation on HL-2A. Preliminary experiments with limiter and single null divertor configurations were carried out in 2003. Main parameters achieved are the plasma current 168 KA, duration time of 920 ms and plasma linear-averaged density of 1.7 x 10 19 m -3 . The impurities, especially of low Z, are clearly decreased during the divertor experiments

  12. Guidelines and Ethical Considerations for Assessment Center Operations: International Task Force on Assessment Center Guidelines.

    Science.gov (United States)

    Public Personnel Management, 2000

    2000-01-01

    This update of the International Personnel Management Association's guidelines for organizational psychologists, human resource management specialists, and others addresses elements of assessment centers, policy statements, assessor training, informed participation, and participants' rights. (SK)

  13. Idiopathic granulomatous lobular mastitis - report of 43 cases from iran; introducing a preliminary clinical practice guideline.

    Science.gov (United States)

    Omranipour, Ramesh; Mohammadi, S-Farzad; Samimi, Parisa

    2013-12-01

    We aimed to report a large series of idiopathic granulomatous lobular mastitis (IGLM) from Iran and sketch preliminary clinical practice guidelines (CPG) for approaching an inflammatory breast mass. In a retrospective records review, 43 consecutive IGLM cases were studied. Data on baseline, clinical, imaging, and pathologic characteristics were collected. The mean age of the women was 33.5 years. All but 1 were married and had given birth. 16% had a cancer-like presentation. Inflammatory signs, architectural distortion, and a nodular pattern were the most common findings clinically, mammographically and ultrasonographically, respectively. 29.5% of the pathological reports indicated necrosis which was more common in younger subjects (p = 0.016); microabscesses were associated with a shorter lactation course (p = 0.006). Corticosteroids had been used as the initial treatment modality in 51%, immunosuppressive agents had not been administered, and a 16% relapse rate was recorded. We recognized the need for a multidisciplinary approach covering radiology, oncology, and surgery to best handle diagnostic and therapeutic issues and manage relevant infections as well as the major differential diagnosis, i.e. malignancy. We hypothesized that a shorter lactation period may cause more milk stasis and extravasation and be contributory to IGLM. CPGs are needed to incorporate the needed multidisciplinary approach and to standardize IGLM care. We present one such guideline.

  14. Preliminary Guideline for the High Temperature Structure Integrity Assessment Procedure Part II. High Temperature Structural Integrity Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Han; Kim, J. B.; Lee, H. Y.; Park, C. G.; Joo, Y. S.; Koo, G. H.; Kim, S. H

    2007-02-15

    A high temperature structural integrity assessment belongs to the Part II of a whole preliminary guideline for the high temperature structure. The main contents of this guideline are the evaluation procedures of the creep-fatigue crack initiation and growth in high temperature condition, the high temperature LBB evaluation procedure, and the inelastic evaluations of the welded joints in SFR structures. The methodologies for the proper inelastic analysis of an SFR structures in high temperatures are explained and the guidelines of inelastic analysis options using ANSYS and ABAQUS are suggested. In addition, user guidelines for the developed NONSTA code are included. This guidelines need to be continuously revised to improve the applicability to the design and analysis of the SFR structures.

  15. SALTO Peer Review Guidelines. Guidelines for Peer Review of Safety Aspects of Long Term Operation of Nuclear Power Plants

    International Nuclear Information System (INIS)

    2014-01-01

    International peer review is a useful tool for Member States to exchange experiences, learn from each other and apply good practices in the long term operation (LTO) of nuclear power plants (NPPs). The peer review is also an important mechanism through which the IAEA supports Member States in enhancing the safety of NPPs. The IAEA has conducted various types of safety review that indirectly address aspects of LTO, including safety reviews for design, engineering, operation and external hazards. Operational Safety Review Team (OSART) services include review of ageing management programmes. In addition, several Member States have requested Ageing Management Assessment Team (AMAT) missions. Through these experiences, it was recognized that a comprehensive peer review on LTO would be very useful to Member States. The Safety Aspects of Long Term Operation (SALTO) peer review addresses strategy and key elements for the safe LTO of NPPs, which includes AMAT objectives and complements OSART reviews. The SALTO peer review is designed to assist operating organizations in adopting a proper approach to LTP including implementing appropriate activities to ensure that plant safety will be maintained during the LTO period. The SALTO peer review can be tailored to focus on ageing management programmes (AMPs) or on other activities related to LTO to support the Member State in enhancing the safety of its NPPs. The SALTO peer review can also support regulators in establishing or improving regulatory and licensing strategies for the LTO of NPPs. The guidelines in this publication are primarily intended for members of a SALTO review team and provide a basic structure and common reference for peer reviews of LTO. Additionally, the guidelines also provide useful information to the operating organizations of NPPs (or technical support organizations) for carrying out their own self-assessments or comprehensive programme reviews. The guidelines are intended to be generic, as there are

  16. The European Stroke Organisation Guidelines : a standard operating procedure

    NARCIS (Netherlands)

    Ntaios, George; Bornstein, Natan M.; Caso, Valeria; Christensen, Hanne; De Keyser, Jacques; Diener, Hans-Christoph; Diez-Tejedor, Exuperio; Ferro, Jose M.; Ford, Gary A.; Grau, Armin; Keller, Emanuella; Leys, Didier; Russell, David; Toni, Danilo; Turc, Guillaume; Van der Worp, Bart; Wahlgren, Nils; Steiner, Thorsten

    2015-01-01

    In 2008, the recently founded European Stroke Organisation published its guidelines for the management of ischemic stroke and transient ischemic attack. This highly cited document was translated in several languages and was updated in 2009. Since then, the European Stroke Organisation has published

  17. National Synchrotron Light Source guidelines for the conduct of operations

    International Nuclear Information System (INIS)

    Fewell, N.

    1990-03-01

    This report briefly discusses the following topics: NSLS operations organization and administration; shift routines and operating practices; NSLS control room activities; communications; control of on-shift training; investigation of abnormal events; notifications; control of equipment and system status; lock-out tagout; independent verification; logkeeping; shift turnover; required reading; shift orders; equipment operations guides; operator aid postings; and equipment labeling

  18. 76 FR 63628 - Preliminary Damage Assessment for Individual Assistance Operations Manual (9327.2-PR)

    Science.gov (United States)

    2011-10-13

    ...] Preliminary Damage Assessment for Individual Assistance Operations Manual (9327.2-PR) AGENCY: Federal... Individual Assistance Operations Manual (9327.2-PR). DATES: Comments must be received by November 14, 2011... of the draft Preliminary Damage Assessment for Individual Assistance Operations Manual (9327.2-PR) on...

  19. Failure of Magnetic Fluid Seals Operating in Water: Preliminary Conclusions

    Directory of Open Access Journals (Sweden)

    Matuszewski Leszek

    2017-06-01

    Full Text Available The article analyses properties of magnetic fluid seals installed in rotary sealing nodes which operate in the utility water environment. Seals of this type have been examined as a possible solution to the problem with ship manoeuvring propulsion sealing. The present analysis bases on laboratory durability tests of magnetic fluid seals exposed to longterm utility water loads, at different water pressures and shaft revolutions. The basic seal durability criterion was the number of revolutions made by the sealing node shaft until the appearance of water tightness loss (leakage. It was found that the main factor leading to the wear of the seal is the relative speed of the magnetic fluid with respect to that of the utility water, and this process is heavily affected by the pressure acting on the seal. The reported test results are presented in the form of diagrams showing the seal durability (time until water tightness loss as a function of rotational speed. The curves shown in the diagrams are regular, with two different rotational speed ranges: the highspeed range, when the tightness loss is relatively fast, and the low-speed range, with a clear tendency to prolong the seal lifetime. These diagrams were given the name of durability curves of the MF seal operating in water. The results of the performed tests suggest formal similarity between the experimental data distribution concerning tightness loss processes occurring in magnetic fluid seals operating in water environment and metal fatigue processes. The article proposes a preliminary simplified durability model to describe the examined phenomenon.

  20. Emergency operating procedures guidelines for pressurized water reactors - a progress report

    International Nuclear Information System (INIS)

    Lyon, W.C.

    1984-01-01

    Emergency Operating Procedures (EOPs) contain the instructions the operator will follow to control a nuclear plant whenever a condition exists that potentially jeopardizes the fuel cladding, the reactor coolant system (RCS) pressure boundary, or the containment. The EOPs are prepared from guidelines which contain the major operator instructions that will be in the EOPs. Guidelines have been prepared by owners' groups having Babcock and Wilcox (BandW), Combustion Engineering (CE), General Electric (GE), and Westinghouse (W) plants. These guidelines cover many aspects of full power operation. Future effort is anticipated to complete coverage of transient events, including severe accidents, all power conditions, and shutdown. This paper describes the philosophy which has guided NRC technical review of guidelines, progress achieved in providing comprehensive coverage of emergency conditions for PWRs, and anticipated future technical activities

  1. Guidelines for the design and operation of makeup water treatment systems

    International Nuclear Information System (INIS)

    Lee, Y.H.; Planek, M.A.; Sopocy, D.M.; Tomaga, C.M.; Abrams, I.M.; Anderson, C.C.; Balazs, M.K.; Houskava, J.; Williams, R.

    1989-06-01

    These guidelines present the industry with a standardized program to ensure the optimum design and operation of their individual makeup water treatment systems. These guidelines present, in a non-technical and non-proprietary format, the makeup water treatment system design and operating topics that are discussed in detail in Volumes 1 and 2 of NP-6377-SL. The individual guidelines contained in Volumes 1 and 2 are presented as separate imperative statements, followed by a technical justification discussion, which provides further explanations. In addition and when applicable, the guidelines relate pertinent operational in regard to monitoring parameters for operation, alternative actions, troubleshooting, management responsibilities and shutdown practices. Design considerations are also addressed, when applicable, in regard to equipment cost and advantages and disadvantages for the design recommendations. Appendices provide background information for performance criteria, component description, economic evaluation procedures and definitions. 4 refs

  2. A Value Function Approach to Information Operations MOE's: A Preliminary Study

    National Research Council Canada - National Science Library

    Doyle, Michael

    1997-01-01

    A value focused thinking approach is applied to information operations. A preliminary value hierarchy for information operations is constructed by extracting the values of senior military leadership from existing doctrine...

  3. PROSPER guidelines: Guidelines for peer review and for plant self-assessment of operational experience feedback process

    International Nuclear Information System (INIS)

    2003-01-01

    Effective use of operational performance information is an important element in any plant operator's arrangements for enhancing the operational safety of a nuclear power plant (NPP). This has been recognized in the IAEA Safety Fundamental, The Safety of Nuclear Installations (Safety Series No. 110). Under the technical aspects of safety, one of the principles of operation and maintenance is that the operating organization and the regulatory body shall establish complementary programmes to analyse operating experience to ensure that lessons are learned and acted upon. Such experience shall be shared with relevant national and international bodies. The Convention on Nuclear Safety, which entered into force in July 1996, also recognized the importance of operational experience feedback as a tool of high importance for the safety of nuclear plant operation and its further enhancement. It follows that the arrangements and results achieved under the operation experience feedback process in Member States will be covered by the national report under the Convention and will be subject to periodical review. These principles are further expanded in the IAEA Safety Standards Safety of Nuclear Power Plants: Operation (Safety Standard Series No. NS-R-2, year 2000) under the Feedback of The IAEA-led Peer Review of the effectiveness of the Operational Safety Performance Experience Review process (PROSPER) and associated guidelines have been developed to provide advice and assistance to utilities or individual power plants to strengthen and enhance the effectiveness of operational experience programmes in achieving these fundamental objectives. The objectives of the former IAEA Assessment of Significant Safety Events Team (ASSET) service have been expanded to include an evaluation of the effective use of all operating performance information available to the plant (e.g. external operating experience, internal low-level and near miss event reports and other relevant operating

  4. Program management aid for redundancy selection and operational guidelines

    Science.gov (United States)

    Hodge, P. W.; Davis, W. L.; Frumkin, B.

    1972-01-01

    Although this criterion was developed specifically for use on the shuttle program, it has application to many other multi-missions programs (i.e. aircraft or mechanisms). The methodology employed is directly applicable even if the tools (nomographs and equations) are for mission peculiar cases. The redundancy selection criterion was developed to insure that both the design and operational cost impacts (life cycle costs) were considered in the selection of the quantity of operational redundancy. These tools were developed as aids in expediting the decision process and not intended as the automatic decision maker. This approach to redundancy selection is unique in that it enables a pseudo systems analysis to be performed on an equipment basis without waiting for all designs to be hardened.

  5. Operability Guidelines For Product Tanker In Heavy Weather In The Adriatic Sea

    Directory of Open Access Journals (Sweden)

    Mudronja Luka

    2014-06-01

    Full Text Available This paper presents operability guidelines for seafarers on a product tanker which navigates in the Adriatic Sea during heavy weather. Tanker route starts from the Otranto strait in the south to the island Krk in the north of Adriatic Sea. Heavy weather is caused by south wind called jugo (blowing from E-SE to SS-E, sirocco family. Operability guidelines are given based on an operability criteria platform for presenting ship seakeeping characteristics. Operability criteria considered in this paper are propeller emergence, deck wetness and bow acceleration of a product tanker. Limiting values of mentioned criteria determine sustainable speed. Heavy weather is described by extreme sea state of 7.5 m wave height. Wave spectrum used in this paper is Tabain spectrum which is developed specifically for Adriatic Sea. Seafarer's approach of decisions making in extreme weather is also shown and servers as a guideline for further research of the authors.

  6. Managing materiality: a preliminary examination of the adoption of the new GRI G4 guidelines on materiality within the business community

    OpenAIRE

    Jones, Peter; Comfort, Daphne; Hillier, David

    2016-01-01

    The concept of materiality emerged as the most important element in the new G4 guideline on corporate sustainability reporting launched by the Global Reporting Initiative (GRI) in 2013. This commentary paper offers a preliminary examination of the way in which these new guidelines are being adopted within the business community. The paper begins with a short discussion of the GRI guidelines and the enhanced emphasis on materiality, and the paper draws its empirical material from the first 10 ...

  7. Guideline for regulatory agencies in evaluating contents of root cause analysis by operators

    International Nuclear Information System (INIS)

    Hata, Takaya; Makino, Maomi; Kosaka, Atsuhiko

    2008-01-01

    'Guideline for Regulatory Agencies in Evaluating Contents of Root cause Analysis by Operators' was enacted as the policy for new inspection system in Japan. The objective is to indicate the view point to verify the appropriateness of the corrective actions and preventive actions implemented by operators based on root cause analysis and its analysis results. This guideline is leading to take four points into special consideration for adequate application. They are encouragement of further activities of the operators, flexible interpretation of the intention, versatility of the analysis methods and concepts and consideration of no blame culture. Moreover, as view point for regulatory agencies, it indicates with special emphasis that neutrality of the analyzing party, objectivity of analysis result, and logicality of the analysis method are ensured. This guideline shall be continuously reviewed through integration of lessons learned from active use in future. (author)

  8. SALTO guidelines. Guidelines for peer review of long term operation and ageing management of nuclear power plants

    International Nuclear Information System (INIS)

    2008-01-01

    other and apply good practices in dealing with LTO of NPPs. The peer review service is also an important mechanism through which the IAEA supports Member States in enhancing the safety of NPPs. The IAEA has conducted various types of safety review services that indirectly address some aspects of LTO, including safety review services for design, engineering, operation and external hazards. OSART (Operational Safety Review Team) services include some review of ageing management programmes. In addition, several Member States have requested AMAT (Ageing Management Assessment Team) missions. Through these activities and considering the increasing average age of NPPs connected to the grid worldwide, it was recognized that a comprehensive engineering safety review service on LTO would be very useful to Member States. The Safe Long Term Operation (SALTO) peer review is a new comprehensive engineering safety review service directly addressing strategy and the key elements for safe LTO of NPPs, which includes AMAT objectives and complements OSART reviews. The SALTO peer review service is designed to assist NPP operators in adopting a proper approach to long term operation of their plants and in implementing complete and appropriate activities to ensure that plant safety will be maintained during the LTO period. The SALTO peer review service can be tailored to focus on AMPs and/or on other programmes related to LTO to support the Member State in enhancing the safety of its NPPs. The SALTO peer review service can also support regulators in establishing or improving regulatory and licensing strategies for LTO of NPPs. These guidelines are primarily intended for members of the SALTO review team and they provide a basic structure and common reference for peer reviews of LTO. However, the guidelines could provide useful information to operating organizations of NPPs (or technical support organizations) for carrying out their own self-assessments or comprehensive programme reviews. The

  9. Safety Standard for Oxygen and Oxygen Systems: Guidelines for Oxygen System Design, Materials Selection, Operations, Storage, and Transportation

    Science.gov (United States)

    1996-01-01

    NASA's standard for oxygen system design, materials selection, operation, and transportation is presented. Minimum guidelines applicable to NASA Headquarters and all NASA Field Installations are contained.

  10. Guidelines for Distribution System Operators on Reactive Power Provision by Electric Vehicles in Low Voltage Grids

    DEFF Research Database (Denmark)

    Zecchino, Antonio; Marinelli, Mattia; Træholt, Chresten

    2017-01-01

    The increasing success of electric vehicles is bringing new technical challenges to power system operators. This work intends to provide guidelines for distribution system operators in terms of reactive power requirements when evaluating and authorizing electric vehicles supply equipment with fast...... the amount of reactive power that an individual electric vehicle is expected to provide when connected to a low voltage feeder, in order to benefit of the desired voltage rise effect in comparison to the case of unitary power factor....

  11. Preliminary guidelines for the evaluation and management of dyslipidemia in adults infected with human immunodeficiency virus and receiving antiretroviral therapy: Recommendations of the Adult AIDS Clinical Trial Group Cardiovascular Disease Focus Group

    NARCIS (Netherlands)

    Dubé, M. P.; Sprecher, D.; Henry, W. K.; Aberg, J. A.; Torriani, F. J.; Hodis, H. N.; Schouten, J. [=Judith; Levin, J.; Myers, G.; Zackin, R.; Nevin, T.; Currier, J. S.

    2000-01-01

    Dyslipidemia is a prevalent condition that affects patients infected with human immunodeficiency virus (HIV) who are receiving antiretroviral therapy, These preliminary recommendations summarize the current understanding in this area and propose guidelines for management. Existing guidelines for the

  12. Guidelines for the presentation of emergency operating procedures using advanced information technology

    International Nuclear Information System (INIS)

    Green, M.; Hollnagel, E.; Niwa, Yuji

    1994-01-01

    New methods of information presentation and interface design are changing the conditions for work in the modern NPP control room. One area receiving considerable attention is that of Emergency Operating Procedures (EOP). Conventionally such procedures are presented using hard copy manuals; however, development in IT means that there are new opportunities for the computerization of such procedures. This paper reports on the development of human factors guidelines for the computerized presentation of EOPs. After identifying the principle stages in the transition from procedures as documents to fully automated procedures, computerised procedure presentation is briefly discussed. Guidelines for the presentation of such procedures are outlined starting with the high level goals for guidelines themselves. Such goals also constitute the criteria against which the computerized procedures are measured during implementation. Six dimensions describing computerized procedure presentation are presented and two are explore in more detail by identifying points along each dimension that characterize different levels of IT sophistication. (author). 8 refs, 1 tab

  13. Preliminary remediation goals for use at the US Department of Energy Oak Ridge Operations Office. Revision 1

    International Nuclear Information System (INIS)

    1996-05-01

    This technical memorandum presents Preliminary Remediation Goals (PRGs) for use in human health risk assessment efforts under the United States Department of Energy, Oak Ridge Operations Office Environmental Restoration (ER) Division. This document provides the ER Division with standardized PRGs which are integral to the Remedial Investigation/Feasibility Study process. They are used during project scooping (Data Quality Objectives development), in screening level risk assessments to support early action or No Further Investigation decisions, and in the baselines risk assessment where they are employed in the selection of chemicals of potential concern. The primary objective of this document is to standardize these values and eliminate any duplication of effort by providing PRGs to all contractors involved in risk activities. In addition, by managing the assumptions and systems used in PRG derivation, the ER Risk Assessment Program will be able to control the level of quality assurance associated with these risk-based guideline values

  14. Preliminary remediation goals for use at the U.S. Department of Energy Oak Ridge Operations Office

    International Nuclear Information System (INIS)

    1995-06-01

    This report presents Preliminary Remediation Goals (PRGs) for use in human health risk assessment efforts under the United States Department of Energy, Oak Ridge Operations Office Environmental Restoration (ER) Division. Chemical-specific PRGs are concentration goals for individual chemicals for specific medium and land use combinations. The PRGs are referred to as risk-based because they have been calculated using risk assessment procedures. Risk-based calculations set concentration limits using both carcinogenic or noncarcinogenic toxicity values under specific exposure pathways. The PRG is a concentration that is derived from a specified excess cancer risk level or hazard quotient. This report provides the ER Division with standardized PRGs which are integral to the Remedial Investigation/Feasibility Study process. By managing the assumptions and systems used in PRG derivation, the Environmental Restoration Risk Assessment Program will be able to control the level of quality assurance associated with these risk-based guideline values

  15. Preliminary remediation goals for use at the U.S. Department of Energy Oak Ridge Operations Office

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-06-01

    This report presents Preliminary Remediation Goals (PRGs) for use in human health risk assessment efforts under the United States Department of Energy, Oak Ridge Operations Office Environmental Restoration (ER) Division. Chemical-specific PRGs are concentration goals for individual chemicals for specific medium and land use combinations. The PRGs are referred to as risk-based because they have been calculated using risk assessment procedures. Risk-based calculations set concentration limits using both carcinogenic or noncarcinogenic toxicity values under specific exposure pathways. The PRG is a concentration that is derived from a specified excess cancer risk level or hazard quotient. This report provides the ER Division with standardized PRGs which are integral to the Remedial Investigation/Feasibility Study process. By managing the assumptions and systems used in PRG derivation, the Environmental Restoration Risk Assessment Program will be able to control the level of quality assurance associated with these risk-based guideline values.

  16. Preliminary remediation goals for use at the US Department of Energy Oak Ridge Operations Office. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-05-01

    This technical memorandum presents Preliminary Remediation Goals (PRGs) for use in human health risk assessment efforts under the United States Department of Energy, Oak Ridge Operations Office Environmental Restoration (ER) Division. This document provides the ER Division with standardized PRGs which are integral to the Remedial Investigation/Feasibility Study process. They are used during project scooping (Data Quality Objectives development), in screening level risk assessments to support early action or No Further Investigation decisions, and in the baselines risk assessment where they are employed in the selection of chemicals of potential concern. The primary objective of this document is to standardize these values and eliminate any duplication of effort by providing PRGs to all contractors involved in risk activities. In addition, by managing the assumptions and systems used in PRG derivation, the ER Risk Assessment Program will be able to control the level of quality assurance associated with these risk-based guideline values.

  17. Preliminary study on psychosomatic status of nuclear power plant operators

    International Nuclear Information System (INIS)

    Bi Jinling; Liu Yulong; Li Yuan; Bian Huahui; Sun Yiling; Qiu Mengyue; Liu Chunfeng

    2011-01-01

    Objective: To understand the operators' psychosomatic health status in nuclear power plant; and provide the scientific basis of measures for preventing and reducing mental disorders in operators. Methods: The Psychosomatic Health Battery (PSHB) was used to assess the psychosomatic health status in 109 operators who were random selected from Qinshan nuclear power plant, etc. They were tested from lie, emotional stability, liveliness, tension, apprehension, mental health, such as psychopathic deviatesuch 7 personality traits. Results: Lie < 8, all inspected groups were normal. Psychopathic deviate: 98.2% for normal group 0.9% for both of groups occurred possible mental health problems and confirmed mental health problems; Mental health: 80.7% (88/109) for fine mental health ones, 29.4% (32/109) for those with excellent mental health, 51.4% (56/109) for good mental health ones, 13.8% (15/109) for general mental health ones, 5.5% (6/109) for poor mental health ones. Age factor could influence the mean values of the factors of apprehension, tension, mental health and psychopathic deviate. Correlation analysis showed that there was a correlation between tension and psychopathic deviate (r=0.664, P<0.01), and the other correlation coefficient was between apprehension and mental health (r=-0.789, P<0.01). Conclusions: There is an excellent condition of psychosomatic health in most of the operators, however, there are still a very small percentage of psychosomatic disorders among these operators, to improve the quality of their psychosomatic health, psychological counseling should be particularly strengthened to those with problems of psychosomatic health. (authors)

  18. MAR flow mapping of Analytical Chemistry Operations (Preliminary Report)

    International Nuclear Information System (INIS)

    Barr, Mary E.; Farish, Thomas J.

    2012-01-01

    The recently released Supplemental Directive, NA-1 SD 1027, updates the radionuclide threshold values in DOE-STD-1027-92 CN1 to reflect the use of modern parameters for dose conversion factors and breathing rates. The directive also corrects several arithmetic errors within the original standard. The result is a roughly four-fold increase in the amount of weapons-grade nuclear material allowed within a designated radiological facility. Radiological laboratory space within the recently constructed Radiological Laboratory Office and Utility Building (RLUOB) is slated to house selected analytical chemistry support activities in addition to small-scale actinide R and D activities. RLUOB is within the same facility operations envelope as TA-55. Consolidation of analytical chemistry activities to RLUOB and PF-4 offers operational efficiency improvements relative to the current pre-CMRR plans of dividing these activities between RLUOB, PF-4, and CMR. RLUOB is considered a Radiological Facility under STD-1027 - 'Facilities that do not meet or exceed Category 3 threshold criteria but still possess some amount of radioactive material may be considered Radiological Facilities.' The supplemental directive essentially increases the allowable material-at-risk (MAR) within radiological facilities from 8.4 g to 38.6 g for 239 Pu. This increase in allowable MAR provides a unique opportunity to establish additional analytical chemistry support functions in RLUOB without negatively impacting either R and D activities or facility operations. Individual radiological facilities are tasked to determine MAR limits (up to the Category 3 thresholds) appropriate to their operational conditions. This study presents parameters that impact establishing MAR limits for RLUOB and an assessment of how various analytical chemistry support functions could operate within the established MAR limits.

  19. Idiopathic Granulomatous Lobular Mastitis – Report of 43 Cases from Iran; Introducing a Preliminary Clinical Practice Guideline

    Science.gov (United States)

    Omranipour, Ramesh; Mohammadi, S-Farzad; Samimi, Parisa

    2013-01-01

    Summary Background We aimed to report a large series of idiopathic granulomatous lobular mastitis (IGLM) from Iran and sketch preliminary clinical practice guidelines (CPG) for approaching an inflammatory breast mass. Patients and Methods In a retrospective records review, 43 consecutive IGLM cases were studied. Data on baseline, clinical, imaging, and pathologic characteristics were collected. Results The mean age of the women was 33.5 years. All but 1 were married and had given birth. 16% had a cancer-like presentation. Inflammatory signs, architectural distortion, and a nodular pattern were the most common findings clinically, mammographically and ultrasonographically, respectively. 29.5% of the pathological reports indicated necrosis which was more common in younger subjects (p = 0.016); microabscesses were associated with a shorter lactation course (p = 0.006). Corticosteroids had been used as the initial treatment modality in 51%, immunosuppressive agents had not been administered, and a 16% relapse rate was recorded. We recognized the need for a multidisciplinary approach covering radiology, oncology, and surgery to best handle diagnostic and therapeutic issues and manage relevant infections as well as the major differential diagnosis, i.e. malignancy. Conclusion We hypothesized that a shorter lactation period may cause more milk stasis and extravasation and be contributory to IGLM. CPGs are needed to incorporate the needed multidisciplinary approach and to standardize IGLM care. We present one such guideline. PMID:24550752

  20. IRS Guidelines: Joint IAEA/NEA International Reporting System for Operating Experience

    International Nuclear Information System (INIS)

    2010-01-01

    The International Reporting System for Operating Experience (IRS) is an international system jointly operated by the International Atomic Energy Agency (IAEA) and the OECD Nuclear Energy Agency (OECD/NEA). The fundamental objective of the IRS is to contribute to improving the safety of commercial nuclear power plants which are operated worldwide. This objective can be achieved by providing timely and detailed information on lessons learned from operating and construction experience at the international level. This information could be related to issues and events that are related to safety. The purpose of these guidelines is to describe the system and to give users the necessary background and guidance to enable them to produce IRS reports meeting a high standard of quality while retaining the effectiveness of the system expected by all Member States operating nuclear power plants. As this system is owned by the Member States, the IRS Guidelines have been developed and approved by the IRS National Co-ordinators with the assistance of both Secretariats (IAEA/NEA).

  1. Preliminary assessment of the Louisiana Home Energy Rebate Offer program using IPMVP guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Kaiser, Mark J.; Pulsipher, Allan G. [Center for Energy Studies, Louisiana State University, Energy Coast and Environment Building, Nicholson Extension Drive, Baton Rouge, LA 70803 (United States)

    2010-02-15

    The Louisiana Home Energy Rebate Offer (HERO) is a residential energy conservation program established in 1999 to provide rebates for qualified applicants to build new homes that are more energy efficient or improve the energy efficiency of existing homes. Energy conservation programs require careful evaluation because of the high cost to implement the measures and the expectation that they will reduce energy use. The purpose of this paper is to demonstrate that residential energy conservation measures in a hot and humid climate can be evaluated using the International Performance Measurement and Verification Protocol (IPMVP), a best practice methodology commonly used in industrial and commercial performance-based contracts, but rarely, if ever, applied to residential programs. Using a random sample of 60 HERO participants, we were able to construct statistically significant electricity consumption baseline models for 90% of households. We determined that more than half of the sample participants consumed more electricity after their efficiency improvement, with an average net household savings of 172 kWh/yr, about 1% pre-retrofit consumption. A description of the baseline model construction, preliminary program evaluation, and recommendations are provided. All program conclusions are considered preliminary until a larger and more comprehensive study is conducted. (author)

  2. Preliminary assessment of the Louisiana Home Energy Rebate Offer program using IPMVP guidelines

    International Nuclear Information System (INIS)

    Kaiser, Mark J.; Pulsipher, Allan G.

    2010-01-01

    The Louisiana Home Energy Rebate Offer (HERO) is a residential energy conservation program established in 1999 to provide rebates for qualified applicants to build new homes that are more energy efficient or improve the energy efficiency of existing homes. Energy conservation programs require careful evaluation because of the high cost to implement the measures and the expectation that they will reduce energy use. The purpose of this paper is to demonstrate that residential energy conservation measures in a hot and humid climate can be evaluated using the International Performance Measurement and Verification Protocol (IPMVP), a best practice methodology commonly used in industrial and commercial performance-based contracts, but rarely, if ever, applied to residential programs. Using a random sample of 60 HERO participants, we were able to construct statistically significant electricity consumption baseline models for 90% of households. We determined that more than half of the sample participants consumed more electricity after their efficiency improvement, with an average net household savings of 172 kWh/yr, about 1% pre-retrofit consumption. A description of the baseline model construction, preliminary program evaluation, and recommendations are provided. All program conclusions are considered preliminary until a larger and more comprehensive study is conducted.

  3. Preliminary design implications of SSC fixed-target operation

    International Nuclear Information System (INIS)

    Zisman, M.S.

    1984-06-01

    This paper covers some of the accelerator physics issues relevant to a possible fixed-target operating mode for the Superconducting Super Collider (SSC). In the brief time available, no attempt has been made to design this capability into the SSC. Rather, I have tried to evaluate what the performance of such a machine might be, and to indicate the hardware implications and extraction considerations that would be part of an actual design study. Where appropriate, parameters and properties of the present LBL design for the SSC have been used; these should be taken as being representative of the general class of small-aperture, high-field colliders being considered by the accelerator physics community. Thus, the numerical examples given here must ultimately be reexamined in light of the actual parameters of the particular accelerator being considered

  4. Operational safety review programmes for nuclear power plants. Guidelines for assessment

    International Nuclear Information System (INIS)

    2002-01-01

    The IAEA has been offering the Operational Safety Review Team (OSART) programme to provide advice and assistance to Member States in enhancing the operational safety of nuclear power plants (NPPs). Simultaneously, the IAEA has encouraged self-assessment and review by Member States of their own nuclear power plants to continuously improve nuclear safety. Currently, some utilities have been implementing safety review programmes to independently review their own plants. Corporate or national operational safety review programmes may be compliance or performance based. Successful utilities have found that both techniques are necessary to provide assurance that (i) as a minimum the NPP meets specific corporate and legal requirements and (ii) management at the NPP is encouraged to pursue continuous improvement principles. These programmes can bring nuclear safety benefits to the plants and utilities. The IAEA has conducted two pilot missions to assess the effectiveness of the operational review programme. Based on these missions and on the experience gained during OSART missions, this document has been developed to provide guidance on and broaden national/corporate safety review programmes in Member States, and to assist in maximizing their benefits. These guidelines are intended primarily for the IAEA team to conduct assessment of a national/corporate safety review programme. However, this report may also be used by a country or utility to establish its own national/corporate safety review programme. The guidelines may likewise be used for self-assessment or for establishing a baseline when benchmarking other safety review programmes. This report consists of four parts. Section 2 addresses the planning and preparation of an IAEA assessment mission and Sections 3 and 4 deal with specific guidelines for conducting the assessment mission itself

  5. Continuity of operations planning in college athletic programs: The case for incorporating Federal Emergency Management Guidelines.

    Science.gov (United States)

    Hall, Stacey A; Allen, Brandon L; Phillips, Dennis

    2016-01-01

    College athletic departments have a responsibility to provide a safe environment for student-athletes; however, most colleges do not have a crisis management plan that includes procedures for displaced student-athletes or alternate facilities to perform athletic events. Continuity of operations planning ensures athletic programs are equipped to maintain essential functions during, or shortly after, a disruption of operations due to possible hazards. Previous studies have identified a lack of emergency preparedness and continuity planning in college athletic departments. The purpose of this article is to illustrate in detail one approach to disaster planning for college athletic departments, namely the Federal Emergency Management Agency (FEMA) continuity of operations framework. By adhering to FEMA guidelines and promoting a best practices model, athletic programs can effectively plan to address potential hazards, as well as protect the organization's brand, image, and financial sustainability after a crisis event.

  6. Guidelines for prediction of irradiation embrittlement of operating WWER-440 reactor pressure vessels

    International Nuclear Information System (INIS)

    2005-06-01

    This TECDOC has been developed under an International Atomic Energy Agency Coordinated Research Project (CRP) entitled Evaluation of Radiation Damage of WWER Reactor Pressure Vessels (RPV) using Database on RPV Materials to develop the guidelines for prediction of radiation damage to WWER-440 PRVs. The WWER-440 RPV was designed by OKB Gidropress, Russian Federation, the general designer. Prediction of irradiation embrittlement of RPV materials is usually done in accordance with relevant codes and standards that are based on the large amounts of information from surveillance and research programmes. The existing Russian code (standard for strength calculations of components and piping in NPPs - PNAE G 7-002-86) for the WWER RPV irradiation embrittlement assessment was approved more than twenty years ago and based mostly on the experimental data obtained in research reactors with accelerated irradiation. Nevertheless, it is still in use and generally consistent with new data. The present publication presents the analyses using all available data required for more precise prediction of radiation embrittlement of WWER-440 RPV materials. Based on the fact that it contains a large amount of data from surveillance programmes as well as research programmes, the IAEA International Database on RPV Materials (IDRPVM) is used for the detailed analysis of irradiation embrittlement of WWER RPV materials. Using IDRPVM, the guideline is developed for assessment of irradiation embrittlement of RPV ferritic materials as a result of degradation during operation. Two approaches, i.e. transition temperatures based on Charpy impact notch toughness, as well as based on static fracture toughness tests, are used in RPV integrity evaluation. The objectives of the TECDOC are the analysis of irradiation embrittlement data for WWER- 440 RPV materials using IDRPVM database, evaluation of predictive formulae depending on chemical composition of the material, neutron fluence, flux, and

  7. EuroFIR Guideline on calculation of nutrient content of foods for food business operators.

    Science.gov (United States)

    Machackova, Marie; Giertlova, Anna; Porubska, Janka; Roe, Mark; Ramos, Carlos; Finglas, Paul

    2018-01-01

    This paper presents a Guideline for calculating nutrient content of foods by calculation methods for food business operators and presents data on compliance between calculated values and analytically determined values. In the EU, calculation methods are legally valid to determine the nutrient values of foods for nutrition labelling (Regulation (EU) No 1169/2011). However, neither a specific calculation method nor rules for use of retention factors are defined. EuroFIR AISBL (European Food Information Resource) has introduced a Recipe Calculation Guideline based on the EuroFIR harmonized procedure for recipe calculation. The aim is to provide food businesses with a step-by-step tool for calculating nutrient content of foods for the purpose of nutrition declaration. The development of this Guideline and use in the Czech Republic is described and future application to other Member States is discussed. Limitations of calculation methods and the importance of high quality food composition data are discussed. Copyright © 2017. Published by Elsevier Ltd.

  8. Guidelines for the content of records to support nuclear power plant operation, maintenance, and modification (NCIG-08): Volume 1, Guidelines: Final report

    International Nuclear Information System (INIS)

    Reedy, R.F.; Hegglin, D.P.

    1988-11-01

    The record systems at many nuclear power plant sites are becoming overloaded with unnecessary and superfluous records. The reason for this overload is that although the Codes and Standards list the record types to be retained, there is no definition for the contents of the records. This encourages varied interpretations which often lead to the approach of ''save everything''. This document provides guidelines for the content of records to support nuclear power plant operation, maintenance and modification. These Guidelines are based on an engineering approach to identify which data in the records are of ''significant value'' in (1) demonstrating capability for safe operation; (2) maintaining, reworking, repairing, replacing, or modifying an item; (3) determining the cause of an accident or malfunction of an item; and (4) providing required baseline data for in-service inspection. Particular topical issues affecting record retention needs, such as plant life extension activities, may require additional evaluation of data or records. By identifying the data to be retained in the records, it is possible to modify the record management system to substantially reduce the amount of unnecessary information being retained in the records. These Guidelines will provide for more uniform interpretation of requirements. The Guidelines are meant as an interpretation of current Codes, Standards and Regulatory Guides, and not as new requirements. Should any conflict exist between these Guidelines and the specified requirements of the NRC Regulations, the regulations govern. 4 tabs

  9. OSART Guidelines. 2015 Edition. Reference Report for IAEA Operational Safety Review Teams (OSARTs)

    International Nuclear Information System (INIS)

    2016-01-01

    The IAEA works to provide a global nuclear safety and security framework for the protection of people and the environment from the effects of ionizing radiation, the minimization of the likelihood of accidents that could endanger life and property, and effective mitigation of the effects of any such events, should they occur. The strategic approach to achieving such a framework involves continual improvement in four areas: national and international safety infrastructures; the establishment and global acceptance of IAEA safety standards; an integrated approach to the provision for the application of the safety standards; and a global network of knowledge and experience. The IAEA Operational Safety Review Team (OSART) programme provides advice and assistance to Member States to enhance the safety of nuclear power plants during commissioning and operation. The OSART programme, initiated in 1982, is available to all Member States with nuclear power plants under commissioning or in operation. Conservative design, careful manufacture and sound construction are all prerequisites for the safe operation of nuclear power plants. However, the safety of the plant also depends ultimately on: sound management, policies, procedures, processes and practices; the capability and reliability of commissioning and operating personnel; comprehensive instructions; sound accident management and emergency preparedness; and adequate resources. Finally, a positive attitude and conscientiousness on the part of all staff in discharging their responsibilities is important to safety. The OSART programme is based on the safety standards applicable to nuclear power plants. IAEA safety standards reflect the consensus of Member States on nuclear safety matters. The reports of the International Nuclear Safety Group identify important current nuclear safety issues and also serve as references during an OSART review. The publication OSART Guidelines provides overall guidance on the conduct of OSART

  10. Guidelines and workbook for assessment of organization and administration of utilities seeking operating license for a nuclear power plant. Guidelines for utility organization and administration plan. Volume 1

    International Nuclear Information System (INIS)

    Thurber, J.A.; Olson, J.; Osborn, R.N.; Sommers, P.; Widrig, R.D.

    1985-08-01

    The Guidelines are intended to provide guidance to the user in preparing a written plan for a proposed nuclear organization and administration. The Guidelines allow for individual approaches to organizational structures to account for differences in plant size, number of operating units, number of plant sites, and the individual utility approach to providing technical support. These unique approaches, however, should meet the criteria of a reasoned, fully developed, and logically consistent focus on the user's organization in terms of organization of work, policies and procedures, staffing, and external relationships

  11. Guidelines for the abandonment operations in the petroleum and gas industry

    International Nuclear Information System (INIS)

    Bedoya V, Julio Cesar; Zapata S, Carmen Elena

    2003-01-01

    Decommission operations, in the hydrocarbons sector, are essential to maintain a clean environment. We propose a guidelines to provide a methodology to standardize the decommission procedures establishing a logical structure in the operations. It shows the generations of possible decommission alternatives. They are picked up in three types, abandonment that is to leave the infrastructure in the place, dismantlement that is the total dismounts of the pieces that compose it, reutilization that will be the new use that will be given to the things. Finally, through an appropriate environmental management, to select the best decommission alternatives that mitigate the impacts and the generation of environmental passives. A project can be presented the abandonment, the reutilization and the dismantlement simultaneously. Also, there are forms to organize and to evaluate the process of decommission. The interdisciplinary work has great importance in this process, as well as an appropriate social management with the affected communities

  12. Crew aiding and automation: A system concept for terminal area operations, and guidelines for automation design

    Science.gov (United States)

    Dwyer, John P.

    1994-01-01

    This research and development program comprised two efforts: the development of guidelines for the design of automated systems, with particular emphasis on automation design that takes advantage of contextual information, and the concept-level design of a crew aiding system, the Terminal Area Navigation Decision Aiding Mediator (TANDAM). This concept outlines a system capable of organizing navigation and communication information and assisting the crew in executing the operations required in descent and approach. In service of this endeavor, problem definition activities were conducted that identified terminal area navigation and operational familiarization exercises addressing the terminal area navigation problem. Both airborne and ground-based (ATC) elements of aircraft control were extensively researched. The TANDAM system concept was then specified, and the crew interface and associated systems described. Additionally, three descent and approach scenarios were devised in order to illustrate the principal functions of the TANDAM system concept in relation to the crew, the aircraft, and ATC. A plan for the evaluation of the TANDAM system was established. The guidelines were developed based on reviews of relevant literature, and on experience gained in the design effort.

  13. Assessing the effectiveness of a guideline recommendation for pre-operative radiochemotherapy in rectal cancer

    International Nuclear Information System (INIS)

    Manchon-Walsh, Paula; Borras, Josep Maria; Espinas, Josep Alfons; Aliste, Luisa

    2011-01-01

    Aim: To ascertain the degree of adherence to the guideline recommendation on pre-operative RT/ChT for stage-II and -III patients in Catalonian public hospitals, and its impact on local recurrence among rectal cancer patients. Methods: Data were derived from a multicentre retrospective cohort study of patients who underwent curative-intent surgery for primary rectal cancer at Catalonian public hospitals in 2005 and 2007. Results: The study covered 1229 patients with TNM stage-II or -III primary rectal cancer. Of these patients, 54.5% underwent pre-operative RT/ChT; 14.9% underwent post-operative RT (± chemotherapy); and 30.6% did not undergo any RT. The crude local recurrence rate at 2 years was 4.1% and the crude distant recurrence rate at 2 years was 6.5%. The results of the univariate analyses showed a local-recurrence hazard ratio of 1.84 for the group of patients that received no RT versus the group that received pre-operative RT/ChT (p < 0.01). Conclusions: This is the first population-based study in Catalonia to support the use of pre-operative RT/ChT in rectal cancer patients because, in line with the results of population-based studies reported from other countries, its application, compared to non-application of RT, was found to lead to a clear reduction in the probability of local recurrence.

  14. Solid Waste Operations Complex W-113: Project cost estimate. Preliminary design report. Volume IV

    International Nuclear Information System (INIS)

    1995-01-01

    This document contains Volume IV of the Preliminary Design Report for the Solid Waste Operations Complex W-113 which is the Project Cost Estimate and construction schedule. The estimate was developed based upon Title 1 material take-offs, budgetary equipment quotes and Raytheon historical in-house data. The W-113 project cost estimate and project construction schedule were integrated together to provide a resource loaded project network

  15. Preliminary guidelines for electricity distributor conservation and demand management activities : a guide for conservation and demand management investment

    International Nuclear Information System (INIS)

    2004-01-01

    In May 2004, electricity distributors in Ontario were asked to submit deferral accounts to the Ontario Energy Board to track expenditures on conservation and demand management initiatives. The deferral accounts must be established before the distributor could recover the costs through the next installment of the allowable return on equity in March 2004. The Board will determine the appropriateness of the actual expenditures. These guidelines offer short-term assistance to distributors in establishing conservation and demand management plans and initiatives. The following specific measures may be supported by the Board: energy efficiency; operational changes to smart control systems; load management measures which facilitate interruptible and dispatchable loads, dual fuel applications, thermal storage and demand response; fuel switching measures; programs targeted to low income and hard to reach consumers; and, distributed energy options such as tri-generation, cogeneration, ground source heat pumps, wind and biomass systems. These guidelines described the regulatory treatment of conservation and demand management investments along with cost effectiveness, allocation of costs, monitoring, evaluation, and implementation. 1 appendix

  16. Criteria for safety related nuclear plant operator actions: a preliminary assessment of available data

    International Nuclear Information System (INIS)

    Haas, P.M.; Bott, T.F.

    1982-01-01

    The need for a quantitative data base on the reliability of nuclear power plant operators has long been recognised by human factors and reliability analysts, and the great need for further assessment of operator performance under accident conditions has been dramatically emphasised by the incident at Three Mile Island-2. In the US, an effort has been under way for a number of years to develop a design standard to define when required manual operator action can be accepted as part of a nuclear plant design basis. To provide the necessary data base to support such standards and the necessary quantitative assessment of operator reliability, the US Nuclear Regulatory Commission is sponsoring a study at Oak Ridge National Laboratory to develop the data base. A preliminary assessment, completed in April 1979, concluded that sufficient data from US operating experience did not exist to provide an adequate data base. A programme of research using full-scope nuclear plant simulators and results that are correlated to field data was suggested. That programme was recently initiated. This paper reviews the approach, results and conclusions of the preliminary assessment and summarises the planned research programme of simulator studies. (author)

  17. Comparative Analyses on OPR1000 Steam Generator Tube Rupture Event Emergency Operational Guideline

    International Nuclear Information System (INIS)

    Lee, Sang Won; Bae, Yeon Kyoung; Kim, Hyeong Teak

    2006-01-01

    The Steam Generator Tube Rupture (SGTR) event is one of the important scenarios in respect to the radiation release to the environment. When the SGTR occurs, containment integrity is not effective because of the direct bypass of containment via the ruptured steam generator to the MSSV and MSADV. To prevent this path, the Emergency Operational Guideline of OPR1000 indicates the use of Turbine Bypass Valves (TBVs) as an effective means to depressurize the main steam line and prevent the lifting of MSSV. However, the TBVs are not operable when the offsite power is not available (LOOP). In this situation, the RCS cool-down is achieved by opening the both intact and ruptured SG MSADV. But this action causes the large amount of radiation release to the environment. To minimize the radiation release to the environment, KSNP EOG adopts the improved strategy when the SGTR concurrently with LOOP is occurred. However, these procedures show some duplicated procedure and branch line that might confusing the operator for optimal recovery action. So, in this paper, the comparative analysis on SGTR and SGTR with LOOP is performed and optimized procedure is proposed

  18. OSART guidelines - 2005 edition. Reference report for IAEA Operational Safety Review Teams (OSARTs)

    International Nuclear Information System (INIS)

    2005-01-01

    when exchanging ideas, at the working level, for enhancing safety. The OSART programme is based on the IAEA's Nuclear Safety Standard Series (Fundamentals, Requirements and Safety Guides) for nuclear power plants and the Basic Safety Standards for Radiation Protection. The Nuclear Safety Standards reflect the consensus of Member States on nuclear safety matters. The reports of the International Nuclear Safety Advisory Group, identifying important current nuclear safety issues also serve as references during an OSART review. The OSART Guidelines provide overall guidance for the experts to ensure the consistency and comprehensiveness of the operational safety review. Additional guidance and reference material prepared by the IAEA and the expertise of the OSART members contribute to the bases of the review. OSART reviews are performance oriented in that they accept different approaches to commissioning and operational safety that represent good practices and may contribute to ensuring a good safety record on the part of the operating organization. Recommendations are made on items of direct relevance to safety, whereas suggestions made might enhance plant safety indirectly but would certainly improve performance. Commendable good practices identified at plants are communicated to other plants where relevant in order to effect improvements. This revision of the OSART guidelines supersedes the 1994 Edition (IAEA-TECDOC-744)

  19. OSART guidelines - 2005 edition. Reference report for IAEA Operational Safety Review Teams (OSARTs)

    International Nuclear Information System (INIS)

    2008-01-01

    when exchanging ideas, at the working level, for enhancing safety. The OSART programme is based on the IAEA's Nuclear Safety Standard Series (Fundamentals, Requirements and Safety Guides) for nuclear power plants and the Basic Safety Standards for Radiation Protection. The Nuclear Safety Standards reflect the consensus of Member States on nuclear safety matters. The reports of the International Nuclear Safety Advisory Group, identifying important current nuclear safety issues also serve as references during an OSART review. The OSART Guidelines provide overall guidance for the experts to ensure the consistency and comprehensiveness of the operational safety review. Additional guidance and reference material prepared by the IAEA and the expertise of the OSART members contribute to the bases of the review. OSART reviews are performance oriented in that they accept different approaches to commissioning and operational safety that represent good practices and may contribute to ensuring a good safety record on the part of the operating organization. Recommendations are made on items of direct relevance to safety, whereas suggestions made might enhance plant safety indirectly but would certainly improve performance. Commendable good practices identified at plants are communicated to other plants where relevant in order to effect improvements. This revision of the OSART guidelines supersedes the 1994 Edition (IAEA-TECDOC-744)

  20. OSART guidelines - 2005 edition. Reference report for IAEA Operational Safety Review Teams (OSARTs)

    International Nuclear Information System (INIS)

    2007-01-01

    when exchanging ideas, at the working level, for enhancing safety. The OSART programme is based on the IAEA's Nuclear Safety Standard Series (Fundamentals, Requirements and Safety Guides) for nuclear power plants and the Basic Safety Standards for Radiation Protection. The Nuclear Safety Standards reflect the consensus of Member States on nuclear safety matters. The reports of the International Nuclear Safety Advisory Group, identifying important current nuclear safety issues also serve as references during an OSART review. The OSART Guidelines provide overall guidance for the experts to ensure the consistency and comprehensiveness of the operational safety review. Additional guidance and reference material prepared by the IAEA and the expertise of the OSART members contribute to the bases of the review. OSART reviews are performance oriented in that they accept different approaches to commissioning and operational safety that represent good practices and may contribute to ensuring a good safety record on the part of the operating organization. Recommendations are made on items of direct relevance to safety, whereas suggestions made might enhance plant safety indirectly but would certainly improve performance. Commendable good practices identified at plants are communicated to other plants where relevant in order to effect improvements. This revision of the OSART guidelines supersedes the 1994 Edition (IAEA-TECDOC-744)

  1. Guidelines for authorities and operators from the EURATOM regulation according to nuclear safety

    International Nuclear Information System (INIS)

    Karpenstein, Ulrich

    2010-01-01

    At 22nd July, 2009 the guideline 2009/71/EURATOM on a community framework for the nuclear security of nuclear installations comes into effect. A lot of regulations of this guideline intervene very deeply in the competencies of the member states. In acknowledgment of the national responsibility for nuclear security, the guideline grants large free space to the member states. Thereby, the guideline aims at a general legal framework and a mutual learning process off.

  2. IAEA/NEA incident reporting system (IRS). Reporting guidelines. Feedback from safety related operating experience for nuclear power plants

    International Nuclear Information System (INIS)

    1998-01-01

    The Incident Reporting System (IRS) is an international system jointly operated by the International Atomic Energy Agency (IAEA) and the Nuclear Energy Agency of the Organisation for Economic Cooperation and Development (OECD/NEA). The fundamental objective of the IRS is to contribute to improving the safety of commercial nuclear power plants (NPPs) which are operated worldwide. This objective can be achieved by providing timely and detailed information on both technical and human factors related to events of safety significance which occur at these plants. The purpose of these guidelines, which supersede the previous IAEA Safety Series No. 93 (Part II) and the NEA IRS guidelines, is to describe the system and to give users the necessary background and guidance to enable them to produce IRS reports meeting a high standard of quality while retaining the high efficiency of the system expected by all Member States operating nuclear power plants. These guidelines have been jointly developed and approved by the NEA/IAEA

  3. Preliminary format design guidelines

    DEFF Research Database (Denmark)

    Tosello, Guido; Calaon, Matteo; Nørregaard, J.

    2013-01-01

    The strategic research centre PolyNano aims at becoming the Danish competence centre for production-ready fabrication of polymer, nano-scale lab-on-a-chip (LoC) devices. In order to provide a competitive edge for Danish biotech companies launching LoC products by removal of the technology barrier...

  4. Microbiological evaluation of various parameters in ophthalmic operating rooms. The need to establish guidelines.

    Directory of Open Access Journals (Sweden)

    Kelkar Uday

    2003-01-01

    Full Text Available Purpose: Postoperative infections can be caused by a contaminated environment, unsterile equipment, contaminated surfaces, and infected personnel as well as contaminated disinfectants. In order to establish guidelines for microbiological monitoring, a detailed microbiological surveillance was carried out in an ophthalmic hospital. Method: Over a period of 21 months, we assessed environmental Bacteria Carrying Particle (BCP load and surface samples weekly (n=276; the autoclaving system once a month and repeated whenever the process failed (n= 24; the air conditioning filters for fungal growth once in four months (n = 15, and the disinfectant solution for contamination once in two months (n = 10. Additionally, the personnel involved directly in surgery were screened for potential pathogens such as Staphylococcus aureus and β haemolytic streptococci. Result: On 14 (5.07% occasions the environment in the operating rooms had a significant risk of airborne infections. Sterilisation of instruments in the autoclaves was unsatisfactory on 4 (16.66 % occasions. Samples from the filters of the air-conditioning units yielded potentially pathogenic fungi on 3 (20% occasions. Personnel sampling revealed that 5 (8.77% individuals harboured β haemolytic Streptococci in the throat and 4 (7.01 % harboured S. aureus in the nasal cavity. The samples of disinfectant in use were not contaminated. Conclusion: There is a need to standardise microbiological evaluation protocols for operating rooms.

  5. Draft Function Allocation Framework and Preliminary Technical Basis for Advanced SMR Concepts of Operations

    Energy Technology Data Exchange (ETDEWEB)

    Hugo, Jacques [Idaho National Lab. (INL), Idaho Falls, ID (United States); Forester, John [Idaho National Lab. (INL), Idaho Falls, ID (United States); Gertman, David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Joe, Jeffrey [Idaho National Lab. (INL), Idaho Falls, ID (United States); Medema, Heather [Idaho National Lab. (INL), Idaho Falls, ID (United States); Persensky, Julius [Idaho National Lab. (INL), Idaho Falls, ID (United States); Whaley, April [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2013-08-01

    This report presents preliminary research results from the investigation into the development of new models and guidance for Concepts of Operations in advanced small modular reactor (AdvSMR) designs. AdvSMRs are nuclear power plants (NPPs), but unlike conventional large NPPs that are constructed on site, AdvSMRs systems and components will be fabricated in a factory and then assembled on site. AdvSMRs will also use advanced digital instrumentation and control systems, and make greater use of automation. Some AdvSMR designs also propose to be operated in a multi-unit configuration with a single central control room as a way to be more cost-competitive with existing NPPs. These differences from conventional NPPs not only pose technical and operational challenges, but they will undoubtedly also have regulatory compliance implications, especially with respect to staffing requirements and safety standards.

  6. The quality of operative note taking: an audit using the Royal College of Surgeons Guidelines as the gold standard.

    Science.gov (United States)

    Shayah, A; Agada, F O; Gunasekaran, S; Jassar, P; England, R J A

    2007-04-01

    To assess the quality of operative note keeping and compare the results with the Royal College of Surgeons (RCS) of England guidelines 'Good Surgical Practice' as the gold standard. ENT Department at Hull Royal Infirmary, University Hospital. A hundred consecutive operative notes were selected between November 2005 and January 2006. The documentation of the operative notes in each case was compared with the RCS of England guidelines. All surgeons were made aware of the results of the first cycle and the guidelines were made available in all ENT theatres in the form of a printed aide-memoir. A second audit cycle was then carried out prospectively between April and June 2006. The results demonstrated a change in practice in key areas. The 1st cycle results showed the documentation of patient identification (94%), name of surgeon (98%) and clearly written postoperative instructions (94%). However, surgeons performed suboptimally at recording the name of assistant (82%), operative diagnosis (46%), the incision type (87%) and the type of wound closure (83%). After introducing the aide-memoir, the second cycle demonstrated a change in practice with 100% documentation in most of the assessed parameters except that the time of surgery and the type of surgery (emergency or elective) were not adequately recorded. We recommend that all surgical departments should have the RCS guidelines as an aide-memoir in theatres to enhance the quality and standardise operative note recording.

  7. Guidelines for operator competence - Optimising facility management processes; Leitfaden Betreiberkompetenz. Schritt fuer Schritt Facility Management Prozesse optimieren

    Energy Technology Data Exchange (ETDEWEB)

    Moser, R

    2005-06-15

    This brochure issued by IFMA (International Facility Management Association) Switzerland and the Swiss Federal Office of Energy (SFOE) presents interactive guidelines for energy management in the area of facility management. These guidelines are based on the results of a project carried out by the International Energy Agency's Annex 40 'Operator competence'. The guidelines provide a step-by-step guide from initial analysis through to successful project completion and answer many questions that may crop up during the process. The focus is placed on energy aspects. Tools and 14 sample process descriptions are provided along with practical examples. Theoretical aspects are also presented and discussed, including models for operator roles and the processes involved. Also, change, risk and knowledge management are examined. Notes and information on possibilities for further education are presented.

  8. Guidelines for operator competence - Optimising facility management processes; Leitfaden Betreiberkompetenz. Schritt fuer Schritt Facility Management Prozesse optimieren

    Energy Technology Data Exchange (ETDEWEB)

    Moser, R.

    2005-06-15

    This brochure issued by IFMA (International Facility Management Association) Switzerland and the Swiss Federal Office of Energy (SFOE) presents interactive guidelines for energy management in the area of facility management. These guidelines are based on the results of a project carried out by the International Energy Agency's Annex 40 'Operator competence'. The guidelines provide a step-by-step guide from initial analysis through to successful project completion and answer many questions that may crop up during the process. The focus is placed on energy aspects. Tools and 14 sample process descriptions are provided along with practical examples. Theoretical aspects are also presented and discussed, including models for operator roles and the processes involved. Also, change, risk and knowledge management are examined. Notes and information on possibilities for further education are presented.

  9. Photovoltaic system criteria documents. Volume 1: Guidelines for evaluating the management and operations planning of photovoltaic applications

    Science.gov (United States)

    Koenig, John C.; Billitti, Joseph W.; Tallon, John M.

    1979-01-01

    Guidelines are provided to the Field Centers for organization, scheduling, project and cost control, and performance in the areas of project management and operations planning for Photovoltaics Test and Applications. These guidelines may be used in organizing a T and A Project Team for system design/test, site construction and operation, and as the basis for evaluating T and A proposals. The attributes are described for project management and operations planning to be used by the Field Centers. Specifically, all project management and operational issues affecting costs, schedules and performance of photovoltaic systems are addressed. Photovoltaic tests and applications include residential, intermediate load center, central station, and stand-alone systems. The sub-categories of system maturity considered are: Initial System Evaluation Experiments (ISEE); System Readiness Experiments (SRE); and Commercial Readiness Demonstration Projects (CRDP).

  10. Regulatory principles, criteria and guidelines for site selection, design, construction and operation of uranium tailings retention systems

    International Nuclear Information System (INIS)

    Coady, J.R.; Henry, L.C.

    1978-01-01

    Principles, criteria and guidelines developed by the Atomic Energy Control Board for the management of uranium mill tailings are discussed. The application of these concepts is considered in relation to site selection, design and construction, operation and decommissioning of tailings retention facilities

  11. Preliminary Concept of Operations for a Global Cylinder Identification and Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Whitaker, J. M. [ORNL; White-Horton, J. L. [ORNL; Morgan, J. B. [InSolves Associates

    2013-08-01

    This report describes a preliminary concept of operations for a Global Cylinder Identification and Monitoring System that could improve the efficiency of the International Atomic Energy Agency (IAEA) in conducting its current inspection activities and could provide a capability to substantially increase its ability to detect credible diversion scenarios and undeclared production pathways involving UF6 cylinders. There exist concerns that a proliferant State with access to enrichment technology could obtain a cylinder containing natural or low-enriched uranium hexafluoride (UF6) and produce a significant quantity (SQ)1 of highly enriched uranium in as little as 30 days. The National Nuclear Security Administration (NNSA) through the Next Generation Safeguards Initiative sponsored a multi-laboratory team to develop an integrated system that provides for detecting scenarios involving 1) diverting an entire declared cylinder for enrichment at a clandestine facility, 2) misusing a declared cylinder at a safeguarded facility, and 3) using an undeclared cylinder at a safeguarded facility. An important objective in developing this integrated system was to improve the timeliness for detecting the cylinder diversion and undeclared production scenarios. Developing this preliminary concept required in-depth analyses of current operational and safeguards practices at conversion, enrichment, and fuel fabrication facilities. The analyses evaluated the processing, movement, and storage of cylinders at the facilities; the movement of cylinders between facilities (including cylinder fabrication); and the misuse of safeguarded facilities.

  12. Preliminary definition of the DOE/OCRWM transportation operating system: Final report

    International Nuclear Information System (INIS)

    Rawl, R.R.; Kline, S.C.

    1988-01-01

    This paper is based on the report ''Preliminary Definition of the Transportation Operations System'' and presents a summary of the preliminary definition of transportation operations activities for the cask shipment cycle, commencing with the dispatch of an empty cask, to loading and unloading of cask contents, and preparation of the empty cask for redispatch. It first presents a high-level description of the transportation cycle and then further describes each of the major activities in greater detail. For simplicity of presentation, the highway mode of transport is most often used to describe activities. The reader should keep in mind that the use of other modes will slightly alter the activities and possibly the sequences. Major activities and functions of the system are organized into a first cut of how they could be allocated to specific facilities. The reader should keep in mind that the assignment of functions and the aggregation of these into specific facilities are tasks which have yet to be performed. This paper simply presents a first look at possible groupings of the functions on a facility basis. 12 figs

  13. Preliminary estimation of the dose rates of the operation room of the RPR radioisotope cell

    International Nuclear Information System (INIS)

    Rocha, A.C.S.; Silva, J.J.G.; Pina, J.L.S. de; Fajardo, P.W.

    1986-07-01

    During the preliminary studies, about the installations layout of a radioisotope production reactor, the possibility of construction of a radioisotope cell at the reactor building has been investigated. The decisions about that construction has considered mainly the level of the radiation dose over the cell operator. The dose rate has been calculated based on: neutron flux and gamma radiation from fission products and activation materials inside the reactor; volatile fission products such as noble gases and iodides; tritium form ternary fission. The objective was calculate the radiation dose over the cell operator during a journey of 8 hours of work per day. For those calculations some data have been obtained from the Angra-3 reactor. (author)

  14. Standing operating procedures for developing acute exposure guideline levels for hazardous chemicals

    National Research Council Canada - National Science Library

    National Research Council (U.S.). Subcommittee on Acute Exposure Guideline Levels

    2001-01-01

    ... Exposure Guideline Levels for Hazardous Chemicals Subcommittee on Acute Exposure Guideline Levels Committee on Toxicology Board on Environmental Studies and Toxicology Commission on Life Sciences National Research Council NATIONAL ACADEMY PRESS Washington, D.C. i Copyrightthe cannot be not from book, paper however, version for formatting, origina...

  15. Draft Function Allocation Framework and Preliminary Technical Basis for Advanced SMR Concepts of Operations

    Energy Technology Data Exchange (ETDEWEB)

    Jacques Hugo; John Forester; David Gertman; Jeffrey Joe; Heather Medema; Julius Persensky; April Whaley

    2013-04-01

    This report presents preliminary research results from the investigation in to the development of new models and guidance for concepts of operations (ConOps) in advanced small modular reactor (aSMR) designs. In support of this objective, three important research areas were included: operating principles of multi-modular plants, functional allocation models and strategies that would affect the development of new, non-traditional concept of operations, and the requiremetns for human performance, based upon work domain analysis and current regulatory requirements. As part of the approach for this report, we outline potential functions, including the theoretical and operational foundations for the development of a new functional allocation model and the identification of specific regulatory requirements that will influence the development of future concept of operations. The report also highlights changes in research strategy prompted by confirmationof the importance of applying the work domain analysis methodology to a reference aSMR design. It is described how this methodology will enrich the findings from this phase of the project in the subsequent phases and help in identification of metrics and focused studies for the determination of human performance criteria that can be used to support the design process.

  16. OSART guidelines

    International Nuclear Information System (INIS)

    1988-02-01

    The IAEA Operational Safety Review Team (OSART) programme provides advice and assistance to Member States to enhance the operational safety of nuclear power plants. These OSART Guidelines provide overall guidance for the experts to ensure the consistency and comprehensiveness of the operational safety review. Specific guidelines are provided as guide for the systematic review in the following areas important to operational safety: management, organization and administration, training and qualification, operations, maintenance, technical support, radiation protection, chemistry, emergency planning and preparedness

  17. Preliminary evaluation of rotational Vol-oxidizer for hot cell operation - 5320

    International Nuclear Information System (INIS)

    Kim, Y.H.; Lee, J.W.; Cho, Y.Z.; Ahn, D.H.; Song, K.C.

    2015-01-01

    KAERI is developing a mechanical head-end process for pyro-processing. As a piece of the processing equipment, a vol-oxidizer that can handle several tens of kg of HM/batch is under development to supply U 3 O 8 powders to an electrolytic reduction (ER) reactor. To operate a vol-oxidizer in a hot cell, the reactor should be optimized by the mechanical design, and the vol-oxidizer should have a high hull recovery rate. In addition, a vol-oxidizer for hot cell demonstrations that handles the spent fuel of high radiation virulence in a limited space should have a small size and not scatter in its outlet. In this paper, we aim at a preliminary evaluation of a rotational vol-oxidizer for hot cell operation. To evaluate the preliminary situation, we produced a theoretical equation of an optimum reactor size, and verification tests were conducted using an acryl vessel and zircaloy-4 tube according to various weights and lengths. In addition, we predicted the terminal velocity of U 3 O 8 using the terminal velocity of SiO 2 , which will determine the optimum air flux, and through an oxidation experiment, we verified the theory form to detect the existence of U 3 O 8 powder in a discharge filter. In addition, hull separation tests were conducted using a reactor and hulls with a 50 kg HM/batch for the recovery rate of the hulls. The results indicate that we obtained an appropriate air flux so as to not cause U 3 O 8 powder dispersion from using a Stokes equation and density ratio equation prior to the demonstration. The optimum flow and experimental results of the hull separation test have been applied for the design of the demonstration oxidizer, and the operation conditions of the oxidizer were produced. (authors)

  18. A novel attention training paradigm based on operant conditioning of eye gaze: Preliminary findings.

    Science.gov (United States)

    Price, Rebecca B; Greven, Inez M; Siegle, Greg J; Koster, Ernst H W; De Raedt, Rudi

    2016-02-01

    Inability to engage with positive stimuli is a widespread problem associated with negative mood states across many conditions, from low self-esteem to anhedonic depression. Though attention retraining procedures have shown promise as interventions in some clinical populations, novel procedures may be necessary to reliably attenuate chronic negative mood in refractory clinical populations (e.g., clinical depression) through, for example, more active, adaptive learning processes. In addition, a focus on individual difference variables predicting intervention outcome may improve the ability to provide such targeted interventions efficiently. To provide preliminary proof-of-principle, we tested a novel paradigm using operant conditioning to train eye gaze patterns toward happy faces. Thirty-two healthy undergraduates were randomized to receive operant conditioning of eye gaze toward happy faces (train-happy) or neutral faces (train-neutral). At the group level, the train-happy condition attenuated sad mood increases following a stressful task, in comparison to train-neutral. In individual differences analysis, greater physiological reactivity (pupil dilation) in response to happy faces (during an emotional face-search task at baseline) predicted decreased mood reactivity after stress. These Preliminary results suggest that operant conditioning of eye gaze toward happy faces buffers against stress-induced effects on mood, particularly in individuals who show sufficient baseline neural engagement with happy faces. Eye gaze patterns to emotional face arrays may have a causal relationship with mood reactivity. Personalized medicine research in depression may benefit from novel cognitive training paradigms that shape eye gaze patterns through feedback. Baseline neural function (pupil dilation) may be a key mechanism, aiding in iterative refinement of this approach. (c) 2016 APA, all rights reserved).

  19. Guidelines to Facilitate the Evaluation of Brines for Winter Roadway Maintenance Operations.

    Science.gov (United States)

    2017-09-19

    This document presents guidelines to facilitate the evaluation of brines for winter weather roadway maintenance applications in Texas. Brines are used in anti-icing applications which typically consist of placing liquid snow and ice control chemicals...

  20. International guidelines for prevention and management of post-operative chronic pain following inguinal hernia surgery

    DEFF Research Database (Denmark)

    Alfieri, S; Amid, P K; Campanelli, G

    2011-01-01

    To provide uniform terminology and definition of post-herniorrhaphy groin chronic pain. To give guidelines to the scientific community concerning the prevention and the treatment of chronic groin and testicular pain....

  1. International guidelines for prevention and management of post-operative chronic pain following inguinal hernia surgery

    DEFF Research Database (Denmark)

    Alfieri, S; Amid, P K; Campanelli, G

    2011-01-01

    To provide uniform terminology and definition of post-herniorrhaphy groin chronic pain. To give guidelines to the scientific community concerning the prevention and the treatment of chronic groin and testicular pain.......To provide uniform terminology and definition of post-herniorrhaphy groin chronic pain. To give guidelines to the scientific community concerning the prevention and the treatment of chronic groin and testicular pain....

  2. Operating performance and environmental and safety risks: A preliminary comparison of majors and independents

    International Nuclear Information System (INIS)

    Pulsipher, A.G.; Iledare, W.O.; Baumann, R.H.; Mesyanzhinov, D.

    1995-01-01

    The objective is to compare the safety and environmental records of oil and gas companies operating on the OCS in the Gulf of Mexico over the past decade. The reason for doing so is to help inform public sector policy-makers and private sector decision-makers about the potential safety and environmental risks associated with the expected increased presence of smaller independents in the domestic oil and gas industry in general and on the federal OCS in particular. The preliminary conclusion is that although independents have had a modestly high incidence of fires and explosions than the majors, the difference is not significant statistically and is largely attributable to a few ''bad actors'' rather than demonstrably poorer practice by the group as a whole

  3. Preliminary Validation of the Small Aircraft Transportation System Higher Volume Operations (SATS HVO) Concept

    Science.gov (United States)

    Williams, Daniel; Consiglio, Maria; Murdoch, Jennifer; Adams, Catherine

    2004-01-01

    This document provides a preliminary validation of the Small Aircraft Transportation System (SATS) Higher Volume Operations (HVO) concept for normal conditions. Initial results reveal that the concept provides reduced air traffic delays when compared to current operations without increasing pilot workload. Characteristic to the SATS HVO concept is the establishment of a newly defined area of flight operations called a Self-Controlled Area (SCA) which would be activated by air traffic control (ATC) around designated non-towered, non-radar airports. During periods of poor visibility, SATS pilots would take responsibility for separation assurance between their aircraft and other similarly equipped aircraft in the SCA. Using onboard equipment and simple instrument flight procedures, they would then be better able to approach and land at the airport or depart from it. This concept would also require a new, ground-based automation system, typically located at the airport that would provide appropriate sequencing information to the arriving aircraft. Further validation of the SATS HVO concept is required and is the subject of ongoing research and subsequent publications.

  4. Evaluation of a Pain Management Education Program and Operational Guideline on Nursing Practice, Attitudes, and Pain Management.

    Science.gov (United States)

    Bonkowski, Sara L; De Gagne, Jennie C; Cade, Makia B; Bulla, Sally A

    2018-04-01

    Nurses lack adequate pain management knowledge, which can result in poorly managed postsurgical pain. This study aimed to develop, implement, and evaluate pain management education and operational guidelines to improve nursing knowledge and pain management. This quality improvement project employed convenience samples of surgical oncology nurses and postoperative patients. The intervention involved an online module, live education, and operational guideline for pain management. Nurses completed pre- and postintervention practice and attitudes surveys. Random chart reviews of intravenous narcotic administrations the day before discharge were completed to evaluate whether narcotic administration changed after intervention. Readmissions and Hospital Consumer Assessment of Healthcare Providers and Systems data were collected to determine whether the intervention influenced patient satisfaction. A statistically significant improvement in nursing practice and intravenous narcotic administrations demonstrated changes to pain management practices employed by the nursing staff. Although not statistically significant, fewer pain-related readmissions occurred postintervention. Findings demonstrate that targeted pain management continuing education, paired with operational guidelines, improves nursing practice and decreases intravenous narcotic administrations prior to discharge. J Contin Educ Nurs. 2018;49(4):178-185. Copyright 2018, SLACK Incorporated.

  5. A Preliminary Evaluation of Supersonic Transport Category Vehicle Operations in the National Airspace System

    Science.gov (United States)

    Underwood, Matthew C.; Guminsky, Michael D.

    2015-01-01

    Several public sector businesses and government agencies, including the National Aeronautics and Space Administration are currently working on solving key technological barriers that must be overcome in order to realize the vision of low-boom supersonic flights conducted over land. However, once these challenges are met, the manner in which this class of aircraft is integrated in the National Airspace System may become a potential constraint due to the significant environmental, efficiency, and economic repercussions that their integration may cause. Background research was performed on historic supersonic operations in the National Airspace System, including both flight deck procedures and air traffic controller procedures. Using this information, an experiment was created to test some of these historic procedures in a current-day, emerging Next Generation Air Transportation System (NextGen) environment and observe the interactions between commercial supersonic transport aircraft and modern-day air traffic. Data was gathered through batch simulations of supersonic commercial transport category aircraft operating in present-day traffic scenarios as a base-lining study to identify the magnitude of the integration problems and begin the exploration of new air traffic management technologies and architectures which will be needed to seamlessly integrate subsonic and supersonic transport aircraft operations. The data gathered include information about encounters between subsonic and supersonic aircraft that may occur when supersonic commercial transport aircraft are integrated into the National Airspace System, as well as flight time data. This initial investigation is being used to inform the creation and refinement of a preliminary Concept of Operations and for the subsequent development of technologies that will enable overland supersonic flight.

  6. Exploring Bim for Operational Integrated Asset Management - a Preliminary Study Utilising Real-World Infrastructure Data

    Science.gov (United States)

    Boyes, G. A.; Ellul, C.; Irwin, D.

    2017-10-01

    The use of 3D information models within collaborative working environments and the practice of Building Information Modelling (BIM) are becoming more commonplace within infrastructure projects. Currently used predominantly during the design and construction phase, the use of BIM is capable in theory of providing the information at handover that will satisfy the Asset Information Requirements (AIRs) of the future Infrastructure Manager (IM). One particular challenge is establishing a link between existing construction-centric information and the asset-centric information needed for future operations. Crossrail, a project to build a new high-frequency railway underneath London, is handling many such challenges as they prepare to handover their digital information to the future operator, in particular the need to provide a two-way link between a federated 3D CAD model and an object-relational Asset Information Management System (AIMS). This paper focusses on the potential for improved Asset Management (AM) by integrating BIM and GIS systems and practices, and makes a preliminary report on how 3D spatial queries can be used to establish a two-way relational link between two information systems (3D geometry and asset lists), as well as the challenges being overcome to transform the data to be suitable for AM.

  7. Main-coolant-pump shaft-seal guidelines. Volume 3. Specification guidelines. Final report

    International Nuclear Information System (INIS)

    Fair, C.E.; Greer, A.O.

    1983-03-01

    This report presents a set of guidelines and criteria to aid in the generation of procurement specifications for Main Coolant Pump Shaft Seals. The noted guidelines are developed from EPRI sponsored nuclear power plant seal operating experience studies, a review of pump and shaft seal literature and discussions with pump and seal designers. This report is preliminary in nature and could be expanded and finalized subsequent to completion of further design, test and evaluation efforts

  8. Characterization of the Darwin direct implicit particle-in-cell method and resulting guidelines for operation

    International Nuclear Information System (INIS)

    Gibbons, M.R.; Hewett, D.W.

    1997-01-01

    We investigate the linear dispersion and other properties of the Darwin Direct Implicit Particle-in-cell (DADIPIC) method in order to deduce guidelines for its use in the simulation of long time-scale, kinetic phenomena in plasmas. The Darwin part of this algorithm eliminates the Courant constraint for light propagation across a grid cell in a time step and divides the field solution into several elliptic equations. The direct implicit method is only applied to the electrostatic field relieving the need to resolve plasma oscillations. Linear theory and simulations verifying the theory are used to generate the desired guidelines as well as show the utility of DADIPIC for a wide range of low frequency, electromagnetic phenomena. We find that separation of the fields has made the task of predicting algorithm behavior easier and produced a robust method without restrictive constraints. 20 refs., 11 figs., 3 tabs

  9. The neutral beam test facility cryopumping operation: preliminary analysis and design of the cryogenic system

    International Nuclear Information System (INIS)

    Gravil, B.; Henry, D.; Cordier, J.J.; Hemsworth, R.; Van Houtte, D.

    2004-01-01

    The ITER neutral beam heating and current drive system is to be equipped with a cryosorption cryopump made up of 12 panels connected in parallel, refrigerated by 4.5 K 0.4 MPa supercritical helium. The pump is submitted to a non homogeneous flux of H 2 or D 2 molecules, and the absorbed flux varies from 3 Pa.m -3 .s -1 to 35 Pa.m -3 .s -1 . In the frame of the 'ITER first injector and test facility CSU-EFDA task' (TW3-THHN-IITF1), the ITER reference cryo-system and cryo-plant designs have been assessed and compared to optimised designs devoted to the Neutral Beam Test Facility (NBTF). The 4.5 K cryo-panel, which has a mass of about 1000 kg, must be periodically regenerated up to 90 K and occasionally to 470 K. The cool-down time after regeneration depends strongly on the refrigeration capacity. Fast regeneration and cool-down of the cryo-panels are not considered a priority for the test facility operation, and an analysis of the consequences of a limited cold power refrigerator on the cooling down time has been carried out and will be discussed. This paper presents a preliminary evaluation of the NBTF cryo-plant and the associated process flow diagram. (authors)

  10. Preliminary performance and operating results from the integrated dry NOx/SO2 emissions control system

    International Nuclear Information System (INIS)

    Hunt, T.; Schott, G.; Smith, R.; Muzio, L.; Jones, D.; Mali E.; Arrigoni, T.

    1993-01-01

    The Integrated Dry NO x /SO 2 Emissions Control System was installed at Public Service Company of Colorado's Arapaho 4 generating station in 1992 in cooperation with the U.S. Department of Energy (DOE) and and the Electric Power Research Institute (EPRI). This full scale 100 MWe demonstration combines low-NO x burners, overfire air, and selective noncatalytic reduction (SNCR) for NO x control and dry sorbent injection with humidification for SO 2 control. Operation and testing of the Integrated Dry NO x /SO 2 Emissions Control System began in August 1992 and will continue through mid 1994. Preliminary results of the NO x control technologies show that the original system goal of 70% NO x removal has been easily met and that NO x removals of up to 80% are possible at full load with the combustion and SNCR systems. Testing of the dry sorbent injection system with low sulfur coal began in April 1993 using a calcium-based reagent. A maximum SO 2 removal of 40% has been achieved with duct injection of commercial calcium hydroxide and humidification to a 25 degrees F approach to saturation. Sodium-based dry sorbent injection is expected to achieved up to a 70% SO 2 reduction

  11. Preliminary Study on Non-Fatal Occupational Injury among Operational Workers in Malaysia Palm Oil Mill

    Directory of Open Access Journals (Sweden)

    Ruslan Rumaizah

    2017-01-01

    Full Text Available Non-fatal occupational injury had becoming major global concern and its consequences to safety and health would be heavily burdening. The aim of this preliminary study was to investigate the distribution of non-fatal occupational injury among specific group of workers in palm oil mill and to acknowledge potential factors of injury causation. A questionnaire survey was designed to assess injury involvement during the employment period among operational workers of palm oil mill located in Southern Peninsular Malaysia. Thirty three (n= 33 workers volunteered and completed the questionnaire. Prevalence of injury among palm oil mill workers was 39.4% with sprain and burn were the common types of injury reported. Press Plant workers reported to have high cases of injuries. Majority of workers (78.8% stated noise was the main hazard in the palm oil mill, followed by heat hazard. Press Plant was identified as one of the specific risk group in palm oil mill based on the rate of injury occurrences reported by the workers. Exposure to noise hazard was estimated to be one of the potential factors of injury causation and further study should be made to measure the risk of hazard.

  12. Manual for the GAW Precipitation Chemistry Programme: Guidelines, Data Quality Objectives and Standard Operating Procedures

    National Research Council Canada - National Science Library

    Allan, Mary A

    2004-01-01

    This is a manual for the Global Atmosphere Watch Precipitation Chemistry (GAW-PC) Programme. Where possible, it describes standard operating procedures and otherwise provides guidance on methods and procedures...

  13. Plant life management for long term operation of light water reactors. Principles and guidelines

    International Nuclear Information System (INIS)

    2006-01-01

    The subject of this report was originally suggested by the IAEA Technical Working Group on Life Management of Nuclear Power Plants. It was then approved by the IAEA for work to begin in 2004. The participants in the group felt that it was time to address plant life management and ageing issues from the point of view of long term operation and licence renewal. It is believed that the nuclear power industry will only be able to survive if plant economics are favourable and safety is maintained. Therefore, the issue of ageing and obsolescence has to be addressed from an operational and safety standpoint, but also in the context of plant economics in terms of the cost of electricity production, including initial and recurring capital costs. Use of new technologies, such as advanced in-service inspection and condition based maintenance, should be considered, not only to predict the consequences of ageing and guard against them, but also to monitor equipment performance throughout the lifetime of the plant and to help establish replacement schedules for critical systems, structures and components, and to better estimate the optimum end of the operating licence, which means the end of the nuclear power plant's lifetime. The importance of nuclear power plant life management in facilitating the technical and economic goals of long term operation is presented in this report in terms of the requirement to ensure safe long term supplies of electricity in the most economically competitive way. Safe and reliable operation is discussed in terms of the overall economic benefits when plant life management is implemented. Preconditions for plant life management for long term operation are identified and approaches are reviewed. Plant life management should not be associated only with the extension of the operational lifetime of the nuclear power plant, but with an owner's attitude and a rational approach of the operating company towards running the business economically and safely

  14. Guidelines for the preparation of emergency operating procedures. Resolution of comments on NUREG-0799

    International Nuclear Information System (INIS)

    1982-08-01

    The purpose of this document is to identify the elements necessary for utilities to prepare and implement a program of Emergency Operating Procedures (EOPs) for use by control room personnel to assist in mitigating the consequences of a broad range of accidents and multiple equipment failures. This document applies only to the EOPs so designated; it does not address emergency preparedness or emergency planning. It also represents the resolution of comments on NUREG-0799, Draft Criteria for Preparation of Emergency Operating Procedures

  15. Hygiene guideline for the planning, installation, and operation of ventilation and air-conditioning systems in health-care settings – Guideline of the German Society for Hospital Hygiene (DGKH

    Directory of Open Access Journals (Sweden)

    Külpmann, Rüdiger

    2016-02-01

    Full Text Available Since the publication of the first “Hospital Hygiene Guideline for the implementation and operation of air conditioning systems (HVAC systems in hospitals” ( in 2002, it was necessary due to the increase in knowledge, new regulations, improved air-conditioning systems and advanced test methods to revise the guideline. Based on the description of the basic features of ventilation concepts, its hygienic test and the usage-based requirements for ventilation, the DGKH section “Ventilation and air conditioning technology” attempts to provide answers for the major air quality issues in the planning, design and the hygienically safe operation of HVAC systems in rooms of health care.

  16. A survey of Korean medicine doctors' clinical practice patterns for autism spectrum disorder: preliminary research for clinical practice guidelines.

    Science.gov (United States)

    Lee, Jihong; Lee, Sun Haeng; Lee, Boram; Yang, In Jun; Chang, Gyu Tae

    2018-03-13

    The aim of this study was to investigate autism spectrum disorder (ASD) clinical practice patterns of Korean medicine doctors (KMDs) through questionnaire survey. Questionnaires on Korean medicine (KM) treatment for ASD were distributed to 255 KMDs on December 5, 2016. The KMDs were psychiatrists, pediatricians, or general practitioners, who treated patients with ASD. The questionnaire covered items on treatment methods, aims of treatment, KM syndrome differentiation, diagnostic tools, and sociodemographic characteristics. Frequency analysis was conducted to describe the participants and their practices. A total 22.4% KMDs (n = 57/255) completed the questionnaires and 54 KMDs (21.2%) matched the inclusion criteria. The KMDs utilized herbal medicine (27.3%), body acupuncture (17.6%), scalp acupuncture (10.7%), moxibustion (6.4%), and Korean medical psychotherapy (5.9%) to treat ASD. The most commonly prescribed herbal medicine was Yukmijihwang-tang. Forty-eight (88.9%) KMDs responded that they used KM syndrome differentiation. 'Organ system, Qi, Blood, Yin, Yang, Fluid and Humor diagnosis' was most frequently used for syndrome differentiation. ASD was mainly diagnosed based on the fourth edition of the Diagnostic and Statistical Manual for Mental Disorders (DSM-IV) and DSM-5. The present study demonstrated the current status of KMDs' diagnosis and treatment of ASD. In future clinical trials and clinical practice guidelines, these findings will provide meaningful information on the actual practice patterns of KMDs.

  17. Best practice guidelines for the operation of a donor human milk bank in an Australian NICU.

    Science.gov (United States)

    Hartmann, B T; Pang, W W; Keil, A D; Hartmann, P E; Simmer, K

    2007-10-01

    Until the establishment of the PREM Bank (Perron Rotary Express Milk Bank) donor human milk banking had not occurred in Australia for the past 20 years. In re-establishing donor human milk banking in Australia, the focus of the PREM Bank has been to develop a formal and consistent approach to safety and quality in processing during the operation of the human milk bank. There is currently no existing legislation in Australia that specifically regulates the operation of donor human milk banks. For this reason the PREM Bank has utilised existing and internationally recognised management practices for managing hazards during food production. These tools (specifically HACCP) have been used to guide the development of Standard Operating Procedures and Good Manufacturing Practice for the screening of donors and processing of donor human milk. Donor screening procedures are consistent with those recommended by other human milk banks operating internationally, and also consistent with the requirements for blood and tissue donation in Australia. Controlled documentation and record keep requirements have also been developed that allow complete traceability from individual donation to individual feed dispensed to recipient and maintain a record of all processing and storage conditions. These operational requirements have been developed to reduce any risk associated with feeding pasteurised donor human milk to hospitalised preterm or ill infants to acceptable levels.

  18. Overview of IAEA guidelines for fire safety inspection and operation in nuclear power plants

    International Nuclear Information System (INIS)

    Mowrer, D.S.

    1998-01-01

    In 1992, the International Atomic Energy Agency began an ambitious project on fire safety in nuclear power plants. The purpose of this ongoing project is to provide specific guidance on compliance with the requirements set forth through the IAEA Nuclear Safety Standards program established in 1974. The scope of the Fire Safety project encompasses several tasks, including the development of new standards and guidelines to assist Member States in assessing the level of fire safety in existing plants. Five new Safety Practices, one new Safety Guide and a Technical Document have been developed for use by the fire safety community. The primary intent of these new documents is to provide detailed guidance and a consistent format for the assessment of the overall level of fire safety being provided in existing nuclear power plants around the world and especially in developing countries. Sufficient detail is provided in the Safety Guide and Safety Practices to allow technically knowledgeable plant personnel, outside consultants or other technical experts to assess the adequacy of fire safety within the plant facilities. This paper describes topics addressed by each of the IAEA Fire Safety documents and discussed the relationship of each document to others in the series. (author)

  19. The need for operating guidelines and a decision making framework applicable to the discovery of non-intelligent extraterrestrial life

    Science.gov (United States)

    Race, Margaret S.; Randolph, Richard O.

    While formal principles have been adopted for the eventuality of detecting intelligent life in our galaxy (SETI Principles), no such guidelines exist for the discovery of non-intelligent extraterrestrial life within the solar system. Current scientifically based planetary protection policies for solar system exploration address how to undertake exploration, but do not provide clear guidance on what to do if and when life is detected. Considering that martian life could be detected under several different robotic and human exploration scenarios in the coming decades, it is appropriate to anticipate how detection of non-intelligent, microbial life could impact future exploration missions and activities, especially on Mars. This paper discusses a proposed set of interim guidelines based loosely on the SETI Principles and addresses issues extending from the time of discovery through future handling and treatment of extraterrestrial life on Mars or elsewhere. Based on an analysis of both scientific and ethical considerations, there is a clear need for developing operating protocols applicable at the time of discovery and a decision making framework that anticipates future missions and activities, both robotic and human. There is growing scientific confidence that the discovery of extraterrestrial life in some form is nearly inevitable. If and when life is discovered beyond Earth, non-scientific dimensions may strongly influence decisions about the nature and scope of future missions and activities. It is appropriate to encourage international discussion and consideration of the issues prior to an event of such historical significance.

  20. [Proposing a physiological model for Emergency Department. Operating principles, classification of overcrowding and guidelines for redesign].

    Science.gov (United States)

    Herrera Carranza, M; Aguado Correa, F; Padilla Garrido, N; López Camacho, F

    2017-04-30

    The operation of Emergency Departments (ED) is determined by demand, their own organizational structures and the connection to other medical care levels. When these elements are not simultaneous, it hinders patient flow and decreases capacity, making it necessary to employ a systemic approach to the chain of emergency care as a single operational entity. With this theoretical orientation, we suggest a conceptual model similar to the physiological cardiac output, in which the preload is the demand, the contractile or flow pump is the organizational structure, the afterload is the hospital, the pre-ED valve is primary care and outpatient emergencies, and the post-ED valve is the diagnostic support services and the specialist consultants. Based on this theoretical approach we classify the different types of ED overcrowding and systematise its causes and the different waiting lists that it generates, which can help to redesign the service and avoid its saturation.

  1. Safety Standard for Hydrogen and Hydrogen Systems: Guidelines for Hydrogen System Design, Materials Selection, Operations, Storage and Transportation. Revision

    Science.gov (United States)

    1997-01-01

    The NASA Safety Standard, which establishes a uniform process for hydrogen system design, materials selection, operation, storage, and transportation, is presented. The guidelines include suggestions for safely storing, handling, and using hydrogen in gaseous (GH2), liquid (LH2), or slush (SLH2) form whether used as a propellant or non-propellant. The handbook contains 9 chapters detailing properties and hazards, facility design, design of components, materials compatibility, detection, and transportation. Chapter 10 serves as a reference and the appendices contained therein include: assessment examples; scaling laws, explosions, blast effects, and fragmentation; codes, standards, and NASA directives; and relief devices along with a list of tables and figures, abbreviations, a glossary and an index for ease of use. The intent of the handbook is to provide enough information that it can be used alone, but at the same time, reference data sources that can provide much more detail if required.

  2. Hip arthroscopy protocol: expert opinions on post-operative weight bearing and return to sports guidelines.

    Science.gov (United States)

    Rath, Ehud; Sharfman, Zachary T; Paret, Matan; Amar, Eyal; Drexler, Michael; Bonin, Nicolas

    2017-01-01

    The objectives of this study are to survey the weight-bearing limitation practices and delay for returning to running and impact sports of high volume hip arthroscopy orthopedic surgeons. The study was designed in the form of expert survey questionnaire. Evidence-based data are scares regarding hip arthroscopy post-operative weight-bearing protocols. An international cross-sectional anonymous Internet survey of 26 high-volume hip arthroscopy specialized surgeons was conducted to report their weight-bearing limitations and rehabilitation protocols after various arthroscopic hip procedures. The International Society of Hip Arthroscopy invited this study. The results were examined in the context of supporting literature to inform the studies suggestions. Four surgeons always allow immediate weight bearing and five never offer immediate weight bearing. Seventeen surgeons provide weight bearing depending on the procedures performed: 17 surgeons allowed immediate weight bearing after labral resection, 10 after labral repair and 8 after labral reconstruction. Sixteen surgeons allow immediate weight bearing after psoas tenotomy. Twenty-one respondents restrict weight bearing after microfracture procedures for 3-8 weeks post-operatively. Return to running and impact sports were shorter for labral procedures and bony procedures and longer for cartilaginous and capsular procedures. Marked variability exists in the post-operative weight-bearing practices of hip arthroscopy surgeons. This study suggests that most surgeons allow immediate weight bearing as tolerated after labral resection, acetabular osteoplasty, chondroplasty and psoas tenotomy. For cartilage defect procedures, 6 weeks or more non-weight bearing is suggested depending on the area of the defect and lateral central edge angle. Delayed return to sports activities is suggested after microfracture procedures. The level of evidence was Level V expert opinions.

  3. Recommendations to ASME for code guidelines and criteria for continued operation of equipment

    International Nuclear Information System (INIS)

    Harvey, J.F.

    1993-01-01

    In May 1988, the American Society of Mechanical Engineers, ASME, asked the Pressure Vessel Research Council, PVRC, to review the part it should play in the continued operation of equipment originally designed and fabricated to the ASME codes and rules. This was prompted solely by an economic opportunity in which the capital expenditures to replace plants was far more costly than evaluating, repairing, and extending the nominal design life of the individual component. For instance, nuclear plants are normally designed for a life of 40 years, while fossil fired facilities may have been designed for other time lives, yet at the end of their original design life may actually have many useful years remaining. While this action was economically prompted, it inherently involved a two-fold one; namely, (1) safety, (2) legal. There is no question of safety to operating personnel. While codes for fossil components do not specify design lives, their adoption by many states provides a legal means of procedure in event of a mishap. This recognizes a cradle-to-grave safety responsibility. It is toward maintaining ASMEs leadership as a code authority that this report has been prepared

  4. Measure Guideline: Condensing Boilers-Optimizing Efficiency and Response Time During Setback Operation

    Energy Technology Data Exchange (ETDEWEB)

    Arena, L. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2014-02-01

    Conventional wisdom surrounding space heating has consistently stated two things: size the mechanical systems to the heating loads, and setting the thermostat back at night will result in energy savings. The problem is these two recommendations oppose each other. A system that is properly sized to the heating load will not have the extra capacity necessary to recover from a thermostat setback, especially at design conditions. The implication of this is that, for setback to be successfully implemented, the heating system must be oversized. This issue is exacerbated further when an outdoor reset control is used with a condensing boiler, because not only is the system matched to the load at design, the outdoor reset control matches the output to the load under varying outdoor temperatures. Under these circumstances, the home may never recover from setback. Special controls to bypass the outdoor reset sensor are then needed. Properly designing a hydronic system for setback operation can be accomplished but depends on several factors. The first step is to determine the appropriateness of setback for a particular project. This is followed by proper sizing of the boiler and baseboard to ensure the needed capacity can be met. Finally, control settings must be chosen that result in the most efficient and responsive performance. This guide provides step-by-step instructions for heating contractors and hydronic designers for selecting the proper control settings to maximize system performance and improve response time when using a thermostat setback.

  5. Measure Guideline: Condensing Boilers - Optimizing Efficiency and Response Time During Setback Operation

    Energy Technology Data Exchange (ETDEWEB)

    Arena, L. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-02-01

    Conventional wisdom surrounding space heating has told us a couple of things consistently for several years now: size the mechanical systems to the heating loads and setting the thermostat back at night will result in energy savings. The problem is these two recommendations oppose each other. A system that is properly sized to the heating load will not have the extra capacity necessary to recover from a thermostat setback, especially at design conditions. The implication of this is that, for setback to be successfully implemented, the heating system must be oversized. This issue is exacerbated further when an outdoor reset control is used with a condensing boiler, because not only is the system matched to the load at design, the outdoor reset control matches the output to the load under varying outdoor temperatures. Under these circumstances, the home may never recover from setback. Special controls to bypass the outdoor reset sensor are then needed. Properly designing a hydronic system for setback operation can be accomplished but depends on several factors. Determining the appropriateness of setback for a particular project is the first step. This is followed by proper sizing of the boiler and baseboard to ensure the needed capacity can be met. Finally, control settings must be chosen that result in the most efficient and responsive performance. This guide provides step by step instructions for heating contractors and hydronic designers for selecting the proper control settings to maximize system performance and improve response time when using a thermostat setback.

  6. Simplified methods and application to preliminary design of piping for elevated temperature service

    International Nuclear Information System (INIS)

    Severud, L.K.

    1975-01-01

    A number of simplified stress analysis methods and procedures that have been used on the FFTF project for preliminary design of piping operating at elevated temperatures are described. The rationale and considerations involved in developing the procedures and preliminary design guidelines are given. Applications of the simplified methods to a few FFTF pipelines are described and the success of these guidelines are measured by means of comparisons to pipeline designs that have had detailed Code type stress analyses. (U.S.)

  7. Comparison of pre-operative dGEMRIC imaging with intra-operative findings in femoroacetabular impingement: preliminary findings

    International Nuclear Information System (INIS)

    Bittersohl, Bernd; Apprich, Sebastian; Siebenrock, Klaus A.; Mamisch, Tallal Charles; Hosalkar, Harish S.; Werlen, Stefan A.

    2011-01-01

    To study standard MRI and dGEMRIC in patients with symptomatic FAI undergoing surgical intervention and compare them with intra-operative findings to see if they were corroborative. Sixteen patients with symptomatic FAI that warranted surgical intervention were prospectively studied. All patients underwent plain radiographic series for FAI assessment followed by standard MRI and dGEMRIC. Subsequently, patients were surgically treated with safe dislocation and the joint was evaluated for any macroscopic signs of damaged cartilage. Data were statistically analyzed. A total of 224 zones in 16 patients were evaluated. One hundred and sixteen zones were intra-operatively rated as normal with mean T1 values of 510.1 ms ± 141.2 ms. Eighty zones had evidence of damage with mean T1 values of 453.1 ms ± 113.6 ms. The difference in these T1 values was significant (p = 0.003). Correlation between standard MRI and intra-operative findings was moderate (r = 0.535, p < 0.001). Intra-operative findings revealed more damage than standard MRI. On standard MRI, 68.6% zones were graded normal while 31.4% had evidence of damage. On intra-operative visualization, 56.4% zones were graded normal and 43.6% had evidence of damage. Correlation between dGEMRIC and intra-operative findings turned out to be weak (r = 0.114, p < 0.126). On T1 assessment 31.4% of zones were graded as normal and 68.6% as damaged. dGEMRIC was significantly different between normal and affected cartilage based on intra-operative assessment. The correlation for morphological findings was limited, underestimating defects. By combining morphological with biochemical assessment dGEMRIC may play some role in the future to prognosticate outcomes and facilitate surgical planning and intervention. (orig.)

  8. 10 CFR 960.5 - Preclosure guidelines.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Preclosure guidelines. 960.5 Section 960.5 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Preclosure Guidelines § 960.5 Preclosure guidelines. The guidelines in this subpart specify the...

  9. 10 CFR 960.3 - Implementation guidelines.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Implementation guidelines. 960.3 Section 960.3 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Implementation Guidelines § 960.3 Implementation guidelines. The guidelines of this subpart...

  10. 10 CFR 960.4 - Postclosure guidelines.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Postclosure guidelines. 960.4 Section 960.4 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Postclosure Guidelines § 960.4 Postclosure guidelines. The guidelines in this subpart specify the...

  11. Preliminary results of Resistive Plate Chambers operated with eco-friendly gas mixtures for application in the CMS experiment

    International Nuclear Information System (INIS)

    Abbrescia, M.; Muhammad, S.; Saviano, G.; Auwegem, P. Van; Cauwenbergh, S.; Tytgat, M.; Benussi, L.; Bianco, S.; Passamonti, L.; Pierluigi, D.; Piccolo, D.; Primavera, F.; Russo, A.; Ferrini, M.

    2016-01-01

    The operations of Resistive Plate Chambers in LHC experiments require Fluorine based (F-based) gases for optimal performance. Recent European regulations demand the use of environmentally unfriendly F-based gases to be limited or banned. In view of the CMS experiment upgrade, several tests are ongoing to measure the performance of the detector with these new ecological gas mixtures, in terms of efficiency, streamer probability, induced charge and time resolution. Prototype chambers with readout pads and with the standard CMS electronic setup are under test. In this paper preliminary results on performance of RPCs operated with a potential eco-friendly gas candidate 1,3,3,3-Tetrafluoropropene, commercially known as HFO-1234ze, with CO 2 and CF 3 I based gas mixtures are presented and discussed for the possible application in the CMS experiment.

  12. Preliminary results of Resistive Plate Chambers operated with eco-friendly gas mixtures for application in the CMS experiment

    CERN Document Server

    Abbrescia, Marcello; Benussi, Luigi; Bianco, Stefano; Cauwenbergh, Simon Marc D; Ferrini, Mauro; Muhammad, Saleh; Passamontic, L; Pierluigi, Daniele; Piccolo, Davide; Primavera, Federica; Russo, Alessandro; Savianoc, G; Tytgat, Michael

    2016-01-01

    The operations of Resistive Plate Chambers in LHC experiments require F-based gases for optimal performance. Recent regulations demand the use of environmentally unfriendly F-based gases to be limited or banned. In view of the CMS experiment upgrade several tests are ongoing to measure the performance of the detector in terms of efficiency, streamer probability, induced charge and time resolution. Prototype chambers with readout pads and with the standard cms electronic setup are under test. In this talk preliminary results on performance of RPCs operated with a potential eco-friendly gas candidate 1,3,3,3-Tetrafluoropropene, commercially known as HFO-1234ze and with CO2 based gas mixtures are presented and discussed for the possible application in the CMS experiment.

  13. Preliminary results of Resistive Plate Chambers operated with eco-friendly gas mixtures for application in the CMS experiment

    CERN Document Server

    Abbrescia, M.

    2016-01-01

    The operations of Resistive Plate Chambers in LHC experiments require Fluorine based (F-based) gases for optimal performance. Recent European regulations demand the use of environmentally unfriendly F-based gases to be limited or banned. In view of the CMS experiment upgrade, several tests are ongoing to measure the performance of the detector with these new ecological gas mixtures, in terms of efficiency, streamer probability, induced charge and time resolution. Prototype chambers with readout pads and with the standard CMS electronic setup are under test. In this paper preliminary results on performance of RPCs operated with a potential eco-friendly gas candidate 1,3,3,3-Tetrafluoropropene, commercially known as HFO-1234ze, with CO2 and CF3I based gas mixtures are presented and discussed for the possible application in the CMS experiment.

  14. Preliminary Performance Data on Westinghouse Electronic Power Regulator Operating on J34-WE-32 Turbojet Engine in Altitude Wind Tunnel

    Science.gov (United States)

    Ketchum, James R.; Blivas, Darnold; Pack, George J.

    1950-01-01

    The behavior of the Westinghouse electronic power regulator operating on a J34-WE-32 turbojet engine was investigated in the NACA Lewis altitude wind tunnel at the request of the Bureau of Aeronautics, Department of the Navy. The object of the program was to determine the, steady-state stability and transient characteristics of the engine under control at various altitudes and ram pressure ratios, without afterburning. Recordings of the response of the following parameters to step changes in power lever position throughout the available operating range of the engine were obtained; ram pressure ratio, compressor-discharge pressure, exhaust-nozzle area, engine speed, turbine-outlet temperature, fuel-valve position, jet thrust, air flow, turbine-discharge pressure, fuel flow, throttle position, and boost-pump pressure. Representative preliminary data showing the actual time response of these variables are presented. These data are presented in the form of reproductions of oscillographic traces.

  15. Preliminary Hybrid Modeling of the Panama Canal: Operations and Salinity Diffusion

    Directory of Open Access Journals (Sweden)

    Luis Rabelo

    2012-01-01

    Full Text Available This paper deals with the initial modeling of water salinity and its diffusion into the lakes during lock operation on the Panama Canal. A hybrid operational model was implemented using the AnyLogic software simulation environment. This was accomplished by generating an operational discrete-event simulation model and a continuous simulation model based on differential equations, which modeled the salinity diffusion in the lakes. This paper presents that unique application and includes the effective integration of lock operations and its impact on the environment.

  16. Hygiene guideline for the planning, installation, and operation of ventilation and air-conditioning systems in health-care settings - Guideline of the German Society for Hospital Hygiene (DGKH).

    Science.gov (United States)

    Külpmann, Rüdiger; Christiansen, Bärbel; Kramer, Axel; Lüderitz, Peter; Pitten, Frank-Albert; Wille, Frank; Zastrow, Klaus-Dieter; Lemm, Friederike; Sommer, Regina; Halabi, Milo

    2016-01-01

    Since the publication of the first "Hospital Hygiene Guideline for the implementation and operation of air conditioning systems (HVAC systems) in hospitals" (http://www.krankenhaushygiene.de/informationen/fachinformationen/leitlinien/12) in 2002, it was necessary due to the increase in knowledge, new regulations, improved air-conditioning systems and advanced test methods to revise the guideline. Based on the description of the basic features of ventilation concepts, its hygienic test and the usage-based requirements for ventilation, the DGKH section "Ventilation and air conditioning technology" attempts to provide answers for the major air quality issues in the planning, design and the hygienically safe operation of HVAC systems in rooms of health care.

  17. 75 FR 75486 - Maritime Security Directive 104-6 (Rev. 4); Guidelines for U.S. Vessels Operating in High Risk...

    Science.gov (United States)

    2010-12-03

    ... Directive 104-6 (Rev. 4); Guidelines for U.S. Vessels Operating in High Risk Waters AGENCY: Coast Guard, DHS... Maritime Transportation Security Act (MTSA) on international voyages through or in designated high risk... MARSEC Directives are available at your local Captain of the Port (COTP) office. Phone numbers and...

  18. 76 FR 2402 - Maritime Security Directive 104-6 (Rev 5); Guidelines for U.S. Vessels Operating in High Risk Waters

    Science.gov (United States)

    2011-01-13

    ... Directive 104-6 (Rev 5); Guidelines for U.S. Vessels Operating in High Risk Waters AGENCY: Coast Guard, DHS... designated high risk waters, and provides additional counter-piracy guidance and mandatory measures for these... MARSEC Directives are available at your local Captain of the Port (COTP) office. Phone numbers and...

  19. Validation of Generic Models for Variable Speed Operation Wind Turbines Following the Recent Guidelines Issued by IEC 61400-27

    Directory of Open Access Journals (Sweden)

    Andrés Honrubia-Escribano

    2016-12-01

    Full Text Available Considerable efforts are currently being made by several international working groups focused on the development of generic, also known as simplified or standard, wind turbine models for power system stability studies. In this sense, the first edition of International Electrotechnical Commission (IEC 61400-27-1, which defines generic dynamic simulation models for wind turbines, was published in February 2015. Nevertheless, the correlations of the IEC generic models with respect to specific wind turbine manufacturer models are required by the wind power industry to validate the accuracy and corresponding usability of these standard models. The present work conducts the validation of the two topologies of variable speed wind turbines that present not only the largest market share, but also the most technological advances. Specifically, the doubly-fed induction machine and the full-scale converter (FSC topology are modeled based on the IEC 61400-27-1 guidelines. The models are simulated for a wide range of voltage dips with different characteristics and wind turbine operating conditions. The simulated response of the IEC generic model is compared to the corresponding simplified model of a wind turbine manufacturer, showing a good correlation in most cases. Validation error sources are analyzed in detail, as well. In addition, this paper reviews in detail the previous work done in this field. Results suggest that wind turbine manufacturers are able to adjust the IEC generic models to represent the behavior of their specific wind turbines for power system stability analysis.

  20. Steps forward in plant operation. From guidelines to a well-structured, usable and maintainable procedure system

    International Nuclear Information System (INIS)

    Forzano, P.; Castagna, P.

    1998-01-01

    The know-how of plant operation, in normal or emergency situations, and maintenance, is typically written in the form of guidelines. Although technical literature is structured in chapters and paragraphs, this type of formalization is still to the level of a 'good practice'. It is informal and subject to individual ability and competence. For many human activities that have intrinsically an high level of formalization, like procedures, it is advisable to analyze the formalism, to extract a set of rules from it, and to collect all the rules in a standard, that should be applicable to a range of specific situations. This papers presents DIAM, a methodology and a tool for procedure management, inspired by practical day-by-day issues: it embeds drawing and documentation standards and offers some new features like automatic flow diagramming and the structuring of large diagrams into pages, the congruence of step names and line paths, and the automatic printout of the procedure book. The automation of many activities offered by DIAM leads to a dramatic reduction in time for drawing productions and think document management in a completely new mode, allowing to abandon the old era of document patching and opening the new era of top quality drawings. (author)

  1. Preliminary evaluation of the Accident Response Mobile Manipulation System for accident site salvage operations

    International Nuclear Information System (INIS)

    Trujillo, J.M.; Morse, W.D.; Jones, D.P.

    1994-01-01

    This paper describes and evaluates operational experiences with the Accident Response Mobile Manipulation System (ARMMS) during simulated accident site salvage operations which might involve nuclear weapons. The ARMMS is based upon a teleoperated mobility platform with two Schilling Titan 7F Manipulators

  2. Preliminary Astrometric Results from the PS1 Demo Month and Routine Survey Operations

    Science.gov (United States)

    2010-09-01

    with the  2MASS  catalog 3 to  produce preliminary astrometric solutions.  Using these  coordinates, the NOFS astrometric pipeline correlates PS1...objects with other catalogs (USNO‐B1.0, SDSS, Tycho‐2,  2MASS , etc.) so that unique star identification numbers can  be assigned across all catalogs. This...correlated  pair, and the standard deviation for these pairings is about  0.3 arcsec.  Whereas the  2MASS  catalog error for a brighter  star is believed to be

  3. Preliminary analysis of the operating characteristics of a generic repository receiving facility: Status report

    International Nuclear Information System (INIS)

    1985-10-01

    The operating characteristics of a repository receiving facility structured around current technology and practices have been reviewed. Cask turnaround times and operator doses were estimated. Large throughout and long-term receiving operations at a nuclear waste repository result in an unprecedented number of casks being handled. While the current generation of material-handling equipment is adequate to process the casks, personnel radiation exposures for the generic facility analyzed are unacceptably high. This emphasizes the need for development of occupational radiation exposure control concepts for application in repository receiving facilities. 3 refs., 22 figs., 6 tabs

  4. Preliminary Investigation of Time Remaining Display on the Computer-based Emergency Operating Procedure

    Science.gov (United States)

    Suryono, T. J.; Gofuku, A.

    2018-02-01

    One of the important thing in the mitigation of accidents in nuclear power plant accidents is time management. The accidents should be resolved as soon as possible in order to prevent the core melting and the release of radioactive material to the environment. In this case, operators should follow the emergency operating procedure related with the accident, in step by step order and in allowable time. Nowadays, the advanced main control rooms are equipped with computer-based procedures (CBPs) which is make it easier for operators to do their tasks of monitoring and controlling the reactor. However, most of the CBPs do not include the time remaining display feature which informs operators of time available for them to execute procedure steps and warns them if the they reach the time limit. Furthermore, the feature will increase the awareness of operators about their current situation in the procedure. This paper investigates this issue. The simplified of emergency operating procedure (EOP) of steam generator tube rupture (SGTR) accident of PWR plant is applied. In addition, the sequence of actions on each step of the procedure is modelled using multilevel flow modelling (MFM) and influenced propagation rule. The prediction of action time on each step is acquired based on similar case accidents and the Support Vector Regression. The derived time will be processed and then displayed on a CBP user interface.

  5. Blistering effects in neutral injection systems operated with helium and hydrogen gases: a preliminary assessment

    International Nuclear Information System (INIS)

    Hamilton, G.W.

    1977-01-01

    The practical effects of blistering and flaking in neutral injection systems are studied. These effects will soon be more important because of energy increases in systems now under development and because of their operation with fast helium ions as well as hydrogen and deuterium ions. Two main effects were studied: enhanced erosion rate and possible voltage breakdown from sharp flakes and gas emission

  6. Preliminary Findings of the South Africa Power System Capacity Expansion and Operational Modelling Study: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Reber, Timothy J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Chartan, Erol Kevin [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Brinkman, Gregory L [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-01-01

    Wind and solar power contract prices have recently become cheaper than many conventional new-build alternatives in South Africa and trends suggest a continued increase in the share of variable renewable energy (vRE) on South Africa's power system with coal technology seeing the greatest reduction in capacity, see 'Figure 6: Percentage share by Installed Capacity (MW)' in [1]. Hence it is essential to perform a state-of-the-art grid integration study examining the effects of these high penetrations of vRE on South Africa's power system. Under the 21st Century Power Partnership (21CPP), funded by the U.S. Department of Energy, the National Renewable Energy Laboratory (NREL) has significantly augmented existing models of the South African power system to investigate future vRE scenarios. NREL, in collaboration with Eskom's Planning Department, further developed, tested and ran a combined capacity expansion and operational model of the South African power system including spatially disaggregated detail and geographical representation of system resources. New software to visualize and interpret modelling outputs has been developed, and scenario analysis of stepwise vRE build targets reveals new insight into associated planning and operational impacts and costs. The model, built using PLEXOS, is split into two components, firstly a capacity expansion model and secondly a unit commitment and economic dispatch model. The capacity expansion model optimizes new generation decisions to achieve the lowest cost, with a full understanding of capital cost and an approximated understanding of operational costs. The operational model has a greater set of detailed operational constraints and is run at daily resolutions. Both are run from 2017 through 2050. This investigation suggests that running both models in tandem may be the most effective means to plan the least cost South African power system as build plans seen to be more expensive than optimal by the

  7. Per-operative vibration analysis: a valuable tool for defining correct stem insertion: preliminary report.

    Science.gov (United States)

    Mulier, Michiel; Pastrav, Cesar; Van der Perre, Georges

    2008-01-01

    Defining the stem insertion end point during total hip replacement still relies on the surgeon's feeling. When a custom-made stem prosthesis with an optimal fit into the femoral canal is used, the risk of per-operative fractures is even greater than with standard prostheses. Vibration analysis is used in other clinical settings and has been tested as a means to detect optimal stem insertion in the laboratory. The first per-operative use of vibration analysis during non-cemented custom-made stem insertion in 30 patients is reported here. Thirty patients eligible for total hip replacement with uncemented stem prosthesis were included. The neck of the stem was connected with a shaker that emitted white noise as excitation signal and an impedance head that measured the frequency response. The response signal was sent to a computer that analyzed the frequency response function after each insertion phase. A technician present in the operating theatre but outside the laminated airflow provided feed-back to the surgeon. The correlation index between the frequency response function measured during the last two insertion hammering sessions was >0.99 in 86.7% of the cases. In four cases the surgeon stopped the insertion procedure because of a perceived risk of fracture. Two special cases illustrating the potential benefit of per-operative vibration analysis are described. The results of intra-operative vibration analysis indicate that this technique may be a useful tool assisting the orthopaedic surgeon in defining the insertion endpoint of the stem. The development of a more user-friendly device is therefore warranted.

  8. A preliminary study on related factors of mental health in nuclear power plant operators

    International Nuclear Information System (INIS)

    Dai Tingting; Liu Yulong; Li Yuan; Liao Haihong; Qiu Mengyue; Bian Huahui; Chen Weibo; Liu Chunfeng

    2012-01-01

    Objective: To explore the status of nuclear power plant operators in mental health and its correlation with emotional stability, liveliness, anxiety and urgency. Methods: 255 male operators were randomly selected from three nuclear power bases, meanwhile 61 undergraduates were used as control group. The mental health and neurobehavioral evaluation system of Chinese nuclear power plant operators was developed by Second Affiliated Hospital of Soochow University, which was used to assess mental health of the subjects. The scores of mental health personality factors were recorded, together with four main personality factors including emotional stability, liveliness, anxiety and urgency. Results: The score of lie was lower than 8 which showed all inspected groups were normal. 1.57% (4/255) operators had psychological disorders, 3.92% (10/255) had poor mental health, 27.84% (71/255) had general mental health, 66.7% (170/255) had excellent mental health, whereas 9.84% (6/61) for control group had psychological disorders. Obvious difference was observed in the final scores between the nuclear power plant operators and control group. The former gained higher scores on mental health,emotional stability,and lower scores on anxiety and urgency (t=3.437, 4.423, -2.493, -2.093, P<0.05). Both groups aged over 27 years and with length of service over 5 years were awarded higher scores on mental health, emotional stability (t=2.585, 2.349; t=2.606, 2.947, P<0.05), lower scores on anxiety and urgency (t=-3.407, -2.138; t=- 2.941, -2.256, P<0.05). The mental health was positively correlated with emotional stability and liveliness (r=0.721, 0.650, P<0.05), but negatively correlated with anxiety and urgency (r=-0.809, -0.693, P<0.05). Conclusions: The majority of nuclear power plant operators had excellent psychological quality, but some factors should be paid more attention, such as different ages and length of service time. (authors)

  9. Pre-Study Walkthrough with a Commercial Pilot for a Preliminary Single Pilot Operations Experiment

    Science.gov (United States)

    O'Connor-Dreher, Ryan; Roberts, Z.; Ziccardi, J.; Vu, K-P. L.; Strybel, T.; Koteskey, Robert William; Lachter, Joel B.; Vi Dao, Quang; Johnson, Walter W.; Battiste, V.

    2013-01-01

    The number of crew members in commercial flights has decreased to two members, down from the five-member crew required 50 years ago. One question of interest is whether the crew should be reduced to one pilot. In order to determine the critical factors involved in safely transitioning to a single pilot, research must examine whether any performance deficits arise with the loss of a crew member. With a concrete understanding of the cognitive and behavioral role of a co-pilot, aeronautical technologies and procedures can be developed that make up for the removal of the second aircrew member. The current project describes a pre-study walkthrough process that can be used to help in the development of scenarios for testing future concepts and technologies for single pilot operations. Qualitative information regarding the tasks performed by the pilots can be extracted with this technique and adapted for future investigations of single pilot operations.

  10. Preliminary study of S-CO{sub 2} cycle control logic for part load operation

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Yoonhan; Lee, Jeong Ik [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2016-05-15

    The benefits of S-CO{sub 2} cycle are relatively high efficiency under the mild turbine inlet temperature region, simple layout configuration and small foot-print. In addition, the safety of the SFR system can be inherently enhanced as the violent sodium-water reaction can be substituted with the mild sodium-CO{sub 2} reaction. 75MWe S-CO{sub 2} recompression cycle with radial type turbomachineries and PCHE was designed. Under various part load conditions (30-100% thermal load), off-design performance of the designed system was assessed, and different control logics were first tested. It was identified that the inventory control strategy is the most efficient logic for the part load operation. In the system operation, the compressor surge condition is seriously considered and controlled to avoid the system damage.

  11. Preliminary Assessment of Operational Hazards and Safety Requirements for Airborne Trajectory Management (ABTM) Roadmap Applications

    Science.gov (United States)

    Cotton, William B.; Hilb, Robert; Koczo, Stefan, Jr.; Wing, David J.

    2016-01-01

    A set of five developmental steps building from the NASA TASAR (Traffic Aware Strategic Aircrew Requests) concept are described, each providing incrementally more efficiency and capacity benefits to airspace system users and service providers, culminating in a Full Airborne Trajectory Management capability. For each of these steps, the incremental Operational Hazards and Safety Requirements are identified for later use in future formal safety assessments intended to lead to certification and operational approval of the equipment and the associated procedures. Two established safety assessment methodologies that are compliant with the FAA's Safety Management System were used leading to Failure Effects Classifications (FEC) for each of the steps. The most likely FEC for the first three steps, Basic TASAR, Digital TASAR, and 4D TASAR, is "No effect". For step four, Strategic Airborne Trajectory Management, the likely FEC is "Minor". For Full Airborne Trajectory Management (Step 5), the most likely FEC is "Major".

  12. Preliminary Concept of Operations for the Spent Fuel Management System--WM2017

    Energy Technology Data Exchange (ETDEWEB)

    Cumberland, Riley M [ORNL; Adeniyi, Abiodun Idowu [ORNL; Howard, Rob L [ORNL; Joseph III, Robert Anthony [ORNL; Jarrell, Joshua J [ORNL; Nutt, Mark [Argonne National Laboratory (ANL)

    2017-01-01

    The Nuclear Fuels Storage and Transportation Planning Project (NFST) within the U.S. Department of Energy s Office of Nuclear Energy is tasked with identifying, planning, and conducting activities to lay the groundwork for developing interim storage and transportation capabilities in support of an integrated waste management system. The system will provide interim storage for commercial spent nuclear fuel (SNF) from reactor sites and deliver it to a repository. The system will also include multiple subsystems, potentially including; one or more interim storage facilities (ISF); one or more repositories; facilities to package and/or repackage SNF; and transportation systems. The project team is analyzing options for an integrated waste management system. To support analysis, the project team has developed a Concept of Operations document that describes both the potential integrated system and inter-dependencies between system components. The goal of this work is to aid systems analysts in the development of consistent models across the project, which involves multiple investigators. The Concept of Operations document will be updated periodically as new developments emerge. At a high level, SNF is expected to travel from reactors to a repository. SNF is first unloaded from reactors and placed in spent fuel pools for wet storage at utility sites. After the SNF has cooled enough to satisfy loading limits, it is placed in a container at reactor sites for storage and/or transportation. After transportation requirements are met, the SNF is transported to an ISF to store the SNF until a repository is developed or directly to a repository if available. While the high level operation of the system is straightforward, analysts must evaluate numerous alternative options. Alternative options include the number of ISFs (if any), ISF design, the stage at which SNF repackaging occurs (if any), repackaging technology, the types of containers used, repository design, component

  13. Preliminary investigation Area 12 fleet operations steam cleaning discharge area Nevada Test Site

    International Nuclear Information System (INIS)

    1996-07-01

    This report documents the characterization activities and findings of a former steam cleaning discharge area at the Nevada Test Site. The former steam cleaning site is located in Area 12 east of Fleet Operations Building 12-16. The characterization project was completed as a required condition of the ''Temporary Water Pollution Control Permit for the Discharge From Fleet Operations Steam Cleaning Facility'' issued by the Nevada Division of Environmental Protection. The project objective was to collect shallow soil samples in eight locations in the former surface discharge area. Based upon field observations, twelve locations were sampled on September 6, 1995 to better define the area of potential impact. Samples were collected from the surface to a depth of approximately 0.3 meters (one foot) below land surface. Discoloration of the surface soil was observed in the area of the discharge pipe and in localized areas in the natural drainage channel. The discoloration appeared to be consistent with the topographically low areas of the site. Hydrocarbon odors were noted in the areas of discoloration only. Samples collected were analyzed for bulk asbestos, Toxicity Characteristic Leaching Procedure (TCLP) metals, total petroleum hydrocarbons (TPHs), volatile organic compounds (VOCs), semi-volatile organic compounds (Semi-VOCs), and gamma scan

  14. Preliminary design and integration of EPICS operation interface for the Taiwan photon source

    International Nuclear Information System (INIS)

    Cheng, Y.S.; Jenny Chen; Chiu, P.C.; Kuo, C.H.; Liao, C.Y.; Hsu, K.T.; Wu, C.Y.

    2012-01-01

    The TPS (Taiwan Photon Source) is the latest generation 3 GeV synchrotron light source which has been in construction since 2010. The EPICS (Experimental Physics and Industrial Control System) framework is adopted as control system infrastructure for the TPS. The EPICS IOCs (Input Output Controller) and various database records have been gradually implemented to control and monitor available subsystems of the TPS at this moment. The subsystem includes timing, power supply, motion controller, miscellaneous Ethernet compliant devices etc. Through EPICS PVs (Process Variables) channel access, remote access I/O data via Ethernet interface can be observed by the usable graphical tool-kits, such as the EDM (Extensible Display Manager) and MATLAB. The operation interface mainly includes the function of setting, reading, save, restore and etc. Integration of operation interfaces will depend upon properties of each subsystem. In addition, the centralized management method is utilized to serve every client from file servers in order to maintain consistent versions of related EPICS files. (authors)

  15. Guidelines for target volume definition in post-operative radiotherapy for prostate cancer, on behalf of the EORTC Radiation Oncology Group

    International Nuclear Information System (INIS)

    Poortmans, Philip; Bossi, Alberto; Vandeputte, Katia; Bosset, Mathieu; Miralbell, Raymond; Maingon, Philippe; Boehmer, Dirk; Budiharto, Tom; Symon, Zvi; Bergh, Alfons C.M. van den; Scrase, Christopher; Poppel, Hendrik van; Bolla, Michel

    2007-01-01

    The appropriate application of 3-D conformal radiotherapy, intensity modulated radiotherapy or image guided radiotherapy for patients undergoing post-operative radiotherapy for prostate cancer requires a standardisation of the target volume definition and delineation as well as standardisation of the clinical quality assurance procedures. Recommendations for this are presented on behalf of the European Organisation for Research and Treatment of Cancer (EORTC) Radiation Oncology Group and in addition to the already published guidelines for radiotherapy as the primary treatment

  16. EXPLORING BIM FOR OPERATIONAL INTEGRATED ASSET MANAGEMENT – A PRELIMINARY STUDY UTILISING REAL-WORLD INFRASTRUCTURE DATA

    Directory of Open Access Journals (Sweden)

    G. A. Boyes

    2017-10-01

    Full Text Available The use of 3D information models within collaborative working environments and the practice of Building Information Modelling (BIM are becoming more commonplace within infrastructure projects. Currently used predominantly during the design and construction phase, the use of BIM is capable in theory of providing the information at handover that will satisfy the Asset Information Requirements (AIRs of the future Infrastructure Manager (IM. One particular challenge is establishing a link between existing construction-centric information and the asset-centric information needed for future operations. Crossrail, a project to build a new high-frequency railway underneath London, is handling many such challenges as they prepare to handover their digital information to the future operator, in particular the need to provide a two-way link between a federated 3D CAD model and an object-relational Asset Information Management System (AIMS. This paper focusses on the potential for improved Asset Management (AM by integrating BIM and GIS systems and practices, and makes a preliminary report on how 3D spatial queries can be used to establish a two-way relational link between two information systems (3D geometry and asset lists, as well as the challenges being overcome to transform the data to be suitable for AM.

  17. Preliminary evaluation of operational parameters in fixed x-ray diagnostics equipment

    International Nuclear Information System (INIS)

    Bacelar, Alexandre; Oliveira, Sandro Soletti de; Streck, Elaine E.; Furtado, Alvaro Porto Alegre; Pinto, Ana Lucia Acosta

    1998-01-01

    In this work they were appraised 22 fixed X-ray diagnostic equipment belonging to three great medical institutions in Porto Alegre - RS, Brazil, with the purpose of demonstrating the importance of the implementation of a Quality Warranty program, advised by a health physicist, in the performance of these equipment. For so some data of alignment and collimation of the beam, peak tube voltage, tube current, transportable charge and exposition time were collected. The results of the tests showed that in only one of the institutions all the equipment remained in operationally acceptable conditions, with relative percent errors below 10%, concerning to the analyzed parameters. This study also showed that the performance of the equipment of the three analyzed institutions is a direct reflex of the maintenance of a Quality Warranty Program, advised by a qualified professional. (author)

  18. Preliminary evaluation of PSCM and BIPP melter design and operating conditions using physical modeling

    International Nuclear Information System (INIS)

    Skarda, R.J.; Hauser, S.G.; Fort, J.A.

    1985-05-01

    The Glass Melter Physical Modeling investigation was initiated to support Pacific Northwest Laboratory (PNL) Hanford Waste Vitrification Program. Specifically, results discussed herein are those of the modeled B-Plant Immobilization Pilot Plant (BIPP) and Pilot Scale Ceramic Melter (PSCM) designs. The purpose of this study was to evaluate various melter design features using laboratory scale models. Hydrodynamic, thermal, and electrical similarity between the modeling fluid and the molten glass were primary objectives. Stroboscopic velocity measurements (flow visualization), temperature measurements, and electrical potential measurements were used to investigate the molten glass behavior. Results from this effort are to provide input to melter design and proposed operation in addition to providing a data base for verifying numerical models. 13 refs., 48 figs., 24 tabs

  19. Preliminary Study of Ideal Operational MHD Beta Limit in HL-2A Tokamak Plasmas

    International Nuclear Information System (INIS)

    Shen Yong; Dong Jiaqi; He Hongda; Turnbull, A. D.

    2009-01-01

    Magnetohydrodynamic (MHD) n = 1 kink mode with n the toroidal mode number is studied and the operational beta limit, constrained by the mode, is calculated for the equilibrium of HL-2A by using the GATO code. Approximately the same beta limit is obtained for configurations with a value of the axial safety factor q 0 both larger and less than 1. Without the stabilization of the conducting wall, the beta limit is found to be 0.821% corresponding to a normalized beta value of β c N = 2.56 for a typical HL-2A discharge with a plasma current I p = 0.245 MA, and the scaling of β c N ∼constant is confirmed. (magnetically confined plasma)

  20. Relevance of intra operative radiotherapy in the treatment of uterine carcinoma - Lyon preliminary experience

    International Nuclear Information System (INIS)

    Gerard, J.P.; Braillon, G.; Gilly, F.N.; Romestaing, P.; Sentenac, I.; Rocher, F.P.; Berger, C.; Chipier, V.; Dargent, D.; Chabert, P.; Raudrant, D.; Adeleine, P.

    1994-01-01

    Aim: Retrospective analysis of Intra operative Radiotherapy (IORT) in recurrent uterine carcinoma (RUC) and prospective pilot study of IORT in advanced cervix cancer (ACC) with high risk of local failure. Patients-Treatments: (1) RUC: from 1988 to 1991, 34 patients with RUC have been treated. Primary cancer was: cervix uterus: 28, endometrium: six. Site of recurrence: centro pelvis: four, latero pelvis: 25, lombo aortic: five. Total gross resection was only possible in 12 patients. A dose of 15 to 22 Gy was given by IORT according to the residual tumour size. External beam irradiation was added in 16 patients; (2) ACC: January 1991 to November 1992, 20 patients were included in this pilot study, stage IIB: seven, stage III: 12, stage IV: 1. Preoperative retroperitoneal pelviscopy showed 13 pN1 patients and NMR imaging ten tumours of 6 cm or larger in diameter. Treatment started with concomitant pelvic irradiation (44 Gy) and one concomitant cycle of 5 Fu-CDDP, followed by a short course of high dose rate upper vagina brachytherapy (4Gy). Four weeks later a radical Wertheim operation was performed together with IORT on the lateral pelvis. Results: (1) RUC: overall survival (Kaplan Meier) at 4 years is 32% (±8). Local relapse in the field of IORT was observed in six patients. Grade 2-3 complications: six patients (radiation proctitis, neuritis, vertebral collapse, ureteral stenosis); (2) ACC: the median follow up is short (18 months). Four cases of pelvic relapse, no postoperative death. The first line radio chemotherapy was associated with two G3 early complications. Postoperative radiation complication was less than 10% G3. Discussion: promising results of IORT in RUC have been observed especially if no irradiation is given during the primary treatment. Good feasibility of the pilot study of IORT in ACC was also observed. It could be followed by a multicentric feasibility trial. (authors). 38 refs., 4 tabs., 1 fig

  1. Operational report, basics of the preliminary project for reconstruction of the RA reactor ventilation system

    International Nuclear Information System (INIS)

    Martinc, R.

    1982-01-01

    This report presents the summary of results needed for designing the reconstruction of the RA reactor ventilation system. The final complete report will published later, including results of possible additional analyses according to the needs of main detailed project. Due to the size of the facility the need of filters for particulates is expected in systems V-1 and V-2, as well as revision of the system V-4. Adsorption filters are not needed in case of operation under regular working conditions. It would be favorable, but not indispensable to construct an adsorption filter that could be used occasionally at the input of V-2 system under the upper water shielding. This filter would be switched on when dehermetization of the reactor is planned and increased radioactivity is indicated in the gas system or experimental space of the RA reactor as well as in case of fuel elements failure. The aim of applying filters is shortening the time these elements would spend in the hermetized reactor i.e. their fast removal from the reactor. It is indispensable to build-in 'emergency' highly efficient adsorption filters in the V-2 system which would be switched on in case of accidents that would cause fuel elements meltdown (with simultaneous accident dehermetization of the heavy water system) [sr

  2. CT-discography in the evaluation of the post-operative lumbar spine. Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Crenier, N; Greselle, J F; Richard, O; Houang, B; Pinol-Daubisse, H; Caille, J M; Vital, J M; Senegas, J

    1988-06-01

    Thirty-three patients with recurrent sciatica after lumbar-disk surgery were studied for recurrent herniated nucleus pulposus (HNP) by CT alone and CT-discography (CTD). Twenty-six patients underwent surgical reexploration allowing correlation with CTD. CTD made a correct diagnosis of recurrent HNP in twenty-one patients showing an extravasation of the contrast medium from the disk space into the medullary canal. In two cases CTD was positive for recurrent HNP but surgery showed only fibrosis. The amount of contrast leak was very small in these two cases along the posterior common longitudinal ligament, and the junction with the disk was very narrow. Because of their clinical presentation three patients with negative studies were operated upon. One showed only fibrosis and the two others showed an associated disk fragment. Among the twenty-one true-positive cases, seven showed a combination of recurrent HNP and scarring. Contamination of CSF by the contrast medium through the dura was observed in two patients. Although a prospective comparative study between CTD and IV-contrast-enhanced CT is necessary, CTD appears to be a useful diagnostic procedure for recurrent HNP after surgery of the lumbar spine.

  3. Preliminary Results and Learning Curve of the Minimally Invasive Chevron Akin Operation for Hallux Valgus.

    Science.gov (United States)

    Jowett, Charlie R J; Bedi, Harvinder S

    Minimally invasive surgery is increasing in popularity. It is relevant in hallux valgus surgery owing to the potential for reduced disruption of the soft tissues and improved wound healing. We present our results and assess the learning curve of the minimally invasive Chevron Akin operation for hallux valgus. A total of 120 consecutive feet underwent minimally invasive Chevron Akin for symptomatic hallux valgus, of which 14 were excluded. They were followed up for a mean of 25 (range 18 to 38) months. The patients were clinically assessed using the American Orthopaedic Foot and Ankle Society score. Complications and patient satisfaction were recorded. The radiographs were analyzed and measurements recorded for hallux valgus and intermetatarsal angle correction. The mean age of the patients undergoing surgery was 55 (range 25 to 81) years. Of the 78 patients, 76 (97.4%) were female and 2 (2.6%) were male; 28 (35.9%) cases were bilateral. The mean American Orthopaedic Foot and Ankle Society score improved from 56 (range 23 to 76) preoperatively to 87 (range 50 to 100) postoperatively (p technique. They display a steep associated learning curve. However, the results are promising, and the learning curve is comparable to that for open hallux valgus surgery. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Preliminary report of a gas conditioner to improve operational reliability of cryotherapy in developing countries

    Directory of Open Access Journals (Sweden)

    Broekhuizen Fredrik

    2006-02-01

    Full Text Available Abstract Background Cryotherapy is a safe, affordable, and effective method of treatment for cervical intraepithelial neoplasia. In some low-resource settings, environmental conditions or qualities of the refrigerant gas can lead to blockage of cryotherapy equipment, terminating treatment. A prototype of a gas conditioner to prevent operational failure was designed, built, and field tested. Methods The prototype conditioner device consists of an expansion chamber that filters and dries the refrigerant gas. Users in Peru and Kenya reported on their experience with the prototype conditioner. In Ghana, simulated cryotherapy procedures were used to test the effects of the prototype conditioner, as well as the commonly used "cough technique." Results Anecdotal reports from field use of the device were favorable. During simulated cryotherapy, the prevalence of blockage during freezing were 0% (0/25 with the device alone, 23.3% (7/30 with the cough technique alone, 5.9% (1/17 with both, and 55.2% (16/29 with neither (Pearson's Chi square = 26.6, df = 3, p Conclusion This prototype design of a cryotherapy gas conditioner is a potential solution for low-resource settings that are experiencing cryotherapy device malfunction.

  5. Sanctions as a tactic used in partner conflicts: theoretical, operational, and preliminary findings.

    Science.gov (United States)

    Winstok, Zeev; Smadar-Dror, Ronit

    2015-07-01

    Partner sanction in this study is a form/tactic of violence, much like verbal and physical violence, which partners use toward each other during their conflicts. The partner sanction embodies a temporary deprivation of a mutually agreed-on right. The purpose of this study is to develop a theoretical and operational framework of sanctions partners use. The study sampled 74 heterosexual couples from the general population (148 male and female participants). The findings support the validity and reliability of the sanction measurement. Furthermore, findings indicate that the use of sanctions between partners is highly prevalent among men and women in the general population; that the more one partner uses sanctions, the more the other partner uses it; and that sanctions are strongly associated with other violent tactics partners use in their conflict (i.e., verbal and physical). Theoretical and empirical implications of the theoretical framework and the findings are discussed, including the role of sanctions in partner conflicts that escalate to severe forms of violence. © The Author(s) 2014.

  6. Derivation of residual radioactive material guidelines for 13 radionuclides present in Operable Unit IV at Brookhaven National Laboratory, Upton, New York

    International Nuclear Information System (INIS)

    Faillace, E.; Nimmagadda, M.; Yu, C.

    1994-12-01

    Residual radioactive material guidelines for 13 radionuclides (americium-241; cobalt-60; cesium-137; europium-152, -154, and -155; plutonium-238, -239, and -240; strontium-90; and uranium-234, -235, and -238) were derived for Operable Unit (OU) IV at Brookhaven National Laboratory. This site has been identified for remedial action under the Comprehensive Environmental Response, Compensation, and Liability Act of 1980, as amended by the Superfund Amendments and Reauthorization Act of 1986. Single-nuclide guidelines were derived on the basis of the requirement that the 50-year committed effective dose equivalent to a hypothetical individual who lives or works in the immediate vicinity of OU IV should not exceed a dose constraint of 30 mrem/yr following remedial action for the current use and plausible future use scenarios or a dose limit of 100 mrem/yr for plausible but less likely future use scenarios. The US Department of Energy (DOE) residual radioactive material guideline computer code, RESRAD, was used in this evaluation; RESRAD implements the methodology described in the DOE manual for determining residual radioactive material guidelines. Four potential scenarios were considered; each assumed that, for a period of 1,000 years following remedial action, the site would be used without radiological restrictions. The four scenarios varied with regard to the type of site use, time spent at the site, and sources of food consumed

  7. A preliminary cyber-physical security assessment of the Robot Operating System (ROS)

    Science.gov (United States)

    McClean, Jarrod; Stull, Christopher; Farrar, Charles; Mascareñas, David

    2013-05-01

    Over the course of the last few years, the Robot Operating System (ROS) has become a highly popular software framework for robotics research. ROS has a very active developer community and is widely used for robotics research in both academia and government labs. The prevalence and modularity of ROS cause many people to ask the question: "What prevents ROS from being used in commercial or government applications?" One of the main problems that is preventing this increased use of ROS in these applications is the question of characterizing its security (or lack thereof). In the summer of 2012, a crowd sourced cyber-physical security contest was launched at the cyber security conference DEF CON 20 to begin the process of characterizing the security of ROS. A small-scale, car-like robot was configured as a cyber-physical security "honeypot" running ROS. DEFFCON-20 attendees were invited to find exploits and vulnerabilities in the robot while network traffic was collected. The results of this experiment provided some interesting insights and opened up many security questions pertaining to deployed robotic systems. The Federal Aviation Administration is tasked with opening up the civil airspace to commercial drones by September 2015 and driverless cars are already legal for research purposes in a number of states. Given the integration of these robotic devices into our daily lives, the authors pose the following question: "What security exploits can a motivated person with little-to-no experience in cyber security execute, given the wide availability of free cyber security penetration testing tools such as Metasploit?" This research focuses on applying common, low-cost, low-overhead, cyber-attacks on a robot featuring ROS. This work documents the effectiveness of those attacks.

  8. Design Guidelines and Criteria for User/Operator Transactions with Battlefield Automated Systems. Volume III-A. Human Factors Analyses of User/ Operator Transactions with TACFIRE - The Tactical Fire Direction System

    Science.gov (United States)

    1981-02-01

    7. Reseaarch Product 81-26 - DESIGN GUIDELINES AND CRITERIA FOR USER/ I;. I’OPERATOR TRANSACTIONS WITH BATTLEFIELD AUTOMIATED SYSTEMS I’ /HVtAN...FACTORS XWLYSES :’F K~R/ OPERATOR TRANSACTIONS WTHT TACFIRE - THE TACTICAL FIRE DiRECTION SY2T3EM A HUMAN FACTORS TECHNICAL AREA L~h~h K L-J 1’ U~~i~ ll...Battlefield Auto- Inter : Oct 1979-Feb 1981 mated Systems Volume III-A: Human Factors 4t C/ Analyses of User/Operator Transactions with 6. PERFORMING

  9. Preliminary Two-Phase Terry Turbine Nozzle Models for RCIC Off-Design Operation Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Haihua [Idaho National Lab. (INL), Idaho Falls, ID (United States); O' Brien, James [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-06-12

    This report presents the effort to extend the single-phase analytical Terry turbine model to cover two-phase off-design conditions. The work includes: (1) adding well-established two-phase choking models – the Isentropic Homogenous Equilibrium Model (IHEM) and Moody’s model, and (2) theoretical development and implementation of a two-phase nozzle expansion model. The two choking models provide bounding cases for the two-phase choking mass flow rate. The new two-phase Terry turbine model uses the choking models to calculate the mass flow rate, the critical pressure at the nozzle throat, and steam quality. In the divergent stage, we only consider the vapor phase with a similar model for the single-phase case by assuming that the liquid phase would slip along the wall with a much slower speed and will not contribute the impulse on the rotor. We also modify the stagnation conditions according to two-phase choking conditions at the throat and the cross-section areas for steam flow at the nozzle throat and at the nozzle exit. The new two-phase Terry turbine model was benchmarked with the same steam nozzle test as for the single-phase model. Better agreement with the experimental data is observed than from the single-phase model. We also repeated the Terry turbine nozzle benchmark work against the Sandia CFD simulation results with the two-phase model for the pure steam inlet nozzle case. The RCIC start-up tests were simulated and compared with the single-phase model. Similar results are obtained. Finally, we designed a new RCIC system test case to simulate the self-regulated Terry turbine behavior observed in Fukushima accidents. In this test, a period inlet condition for the steam quality varying from 1 to 0 is applied. For the high quality inlet period, the RCIC system behaves just like the normal operation condition with a high pump injection flow rate and a nominal steam release rate through the turbine, with the net addition of water to the primary system; for

  10. Preliminary Criticality Calculation on Conceptual Deep Borehole Disposal System for Trans-metal Waste during Operational Phase

    International Nuclear Information System (INIS)

    Kim, In Young; Choi, Heui Joo; Cho, Dong Geun

    2013-01-01

    The primary function of any repository is to prevent spreading of dangerous materials into surrounding environment. In the case of high-level radioactive waste repository, radioactive material must be isolated and retarded during sufficient decay time to minimize radiation hazard to human and surrounding environment. Sub-criticality of disposal canister and whole disposal system is minimum requisite to prevent multiplication of radiation hazard. In this study, criticality of disposal canister and DBD system for trans-metal waste is calculated to check compliance of sub-criticality. Preliminary calculation on criticality of conceptual deep borehole disposal system and its canister for trans-metal waste during operational phase is conducted in this study. Calculated criticalities at every temperature are under sub-criticalities and criticalities of canister and DBD system considering temperature are expected to become 0.34932 and 0.37618 approximately. There are obvious limitations in this study. To obtain reliable data, exact elementary composition of each component, system component temperature must be specified and applied, and then proper cross section according to each component temperature must be adopted. However, many assumptions, for example simplified elementary concentration and isothermal component temperature, are adopted in this study. Improvement of these data must be conducted in the future work to progress reliability. And, post closure criticality analyses including geo, thermal, hydro, mechanical, chemical mechanism, especially fissile material re-deposition by precipitation and sorption, must be considered to ascertain criticality safety of DBD system as a future work

  11. OSART guidelines. 1992 edition

    International Nuclear Information System (INIS)

    1992-01-01

    The IAEA Operational Safety Review Team (OSART) Guidelines provide overall guidance for the experts to ensure the consistency and comprehensiveness of the operational safety review. Specific guidelines are provided as a guide for the systematic review in the following areas important to operational safety: management, organization and administration, training and qualification, operations, maintenance, technical support, radiation protection, chemistry, emergency planning and preparedness. Additional guidance and reference material has been prepared by the IAEA to complement the expertise of the OSART members

  12. Low COST surgery setting for one-operational port laparoscopic hysterectomy surgery with ordinary laparoscopic instruments: preliminary results.

    Science.gov (United States)

    Limberger, Leo Francisco; Campos, Luciana Silveira; da Alves, Nilton Jacinto Rosa; Pedrini, Daniel Siqueira; de Limberger, Andiara Souza

    2013-10-02

    Hysterectomy dates back to 120BC and is the second most commonly performed gynecological surgery in the world. Cosmetic demands and the necessity of rapid return to work have contributed to the minimally invasive laparoscopic approach for hysterectomy. The majority of reports describe the use of three or four incisions to perform the surgery (two or three for manipulation and one for optics). This work describes our experience with using only two ports for 11 patients who underwent video-laparoscopic hysterectomy surgery. One port was used for the optical system, and the second was used for manipulation. Early and late surgery complications, as well as the time to return to work and daily activities, were assessed. The mean age of the patients was 41.4 years old (range 16 to 52 years) and the mean uterine weight was 133.54 g, ranging from 35 g and 291 g. The operative time ranged from 30 to 60 minutes (average 46.4 minutes) and the hospital stay ranged between 24 and 48 hrs. No intraoperative complications occurred, and no early or late postoperative complications were recorded. Patients reported minimal pain during the first 24-48 hrs in the hospital. Patients returned to their daily activities within seven days after surgery. Clinical care follow-up continued until the 40th postoperative day. The laparoscopic hysterectomy technique with a single port for manipulation is a feasible procedure when the uterine weight is not greater than 400 mg with little postoperative pain. The patients had an early return-to-work and daily activities and a better cosmetic outcome. These preliminary data led us to make the one-operative port laparoscopic hysterectomy the procedure of choice for patients with a low uterine weight.

  13. Proposal of a post-prostatectomy clinical target volume based on pre-operative MRI: volumetric and dosimetric comparison to the RTOG guidelines

    International Nuclear Information System (INIS)

    Croke, Jennifer; Maclean, Jillian; Nyiri, Balazs; Li, Yan; Malone, Kyle; Avruch, Leonard; Kayser, Cathleen; Malone, Shawn

    2014-01-01

    Recurrence rates following radiotherapy for prostate cancer in the post-operative adjuvant or salvage setting remain substantial. Previous work from our institution demonstrated that published prostate bed CTV guidelines frequently do not cover the pre-operative MRI defined prostate. Inadequate target delineation may contribute to the high recurrence rates, but increasing target volumes may increase dose to organs at risk. We propose guidelines for delineating post-prostatectomy target volumes based upon an individual’s co-registered pre-operative MRI. MRI-based CTVs and PTVs were compared to those created using the RTOG guidelines in 30 patients. Contours were analysed in terms of absolute volume, intersection volume (Jaccard Index) and the ability to meet the RADICALS and QUANTEC rectal and bladder constraints (tomotherapy IMRT plans with PTV coverage of V98% ≥98%). CTV MRI was a mean of 18.6% larger than CTV RTOG: CTV MRI mean 138 cc (range 72.3 - 222.2 cc), CTV RTOG mean 116.3 cc (range 62.1 - 176.6 cc), (p < 0.0001). The difference in mean PTV was only 4.6%: PTV MRI mean 386.9 cc (range 254.4 – 551.2), PTV RTOG mean 370 cc (range 232.3 - 501.6) (p = 0.05). The mean Jaccard Index representing intersection volume between CTVs was 0.72 and 0.84 for PTVs. Both criteria had a similar ability to meet rectal and bladder constraints. Rectal DVH: 77% of CTV RTOG cases passed all RADICALS criteria and 37% all QUANTEC criteria; versus 73% and 40% for CTV MRI (p = 1.0 for both). Bladder DVH; 47% of CTV RTOG cases passed all RADICALS criteria and 67% all QUANTEC criteria, versus 57% and 60% for CTV MRI (p = 0.61for RADICALS, p = 0.79 for QUANTEC). CTV MRI spares more of the lower anterior bladder wall than CTV RTOG but increases coverage of the superior lateral bladder walls. CTV contours based upon the patient’s co-registered pre-operative MRI in the post-prostatectomy setting may improve coverage of the individual’s prostate bed without substantially increasing

  14. Space Elevators Preliminary Architectural View

    Science.gov (United States)

    Pullum, L.; Swan, P. A.

    Space Systems Architecture has been expanded into a process by the US Department of Defense for their large scale systems of systems development programs. This paper uses the steps in the process to establishes a framework for Space Elevator systems to be developed and provides a methodology to manage complexity. This new approach to developing a family of systems is based upon three architectural views: Operational View OV), Systems View (SV), and Technical Standards View (TV). The top level view of the process establishes the stages for the development of the first Space Elevator and is called Architectural View - 1, Overview and Summary. This paper will show the guidelines and steps of the process while focusing upon components of the Space Elevator Preliminary Architecture View. This Preliminary Architecture View is presented as a draft starting point for the Space Elevator Project.

  15. Advanced control room design review guidelines: Integration of the NUREG-0700 guidelines and development of new human-system interface guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Carter, R.J.

    1997-07-01

    This report documents the work conducted in four tasks of the Nuclear Regulatory Commission (NRC) project entitled Review Criteria for Human Factors Aspects of Advanced Controls and Instrumentation. The purpose of the first task was to integrate the applicable sections of NUREG-0700 into the advanced control room design review (ACRDR) guidelines to ensure that all applicable guidelines are together in one document and conveniently accessible to users. The primary objective of the second task was to formulate a strategy for the development of new ACRDR guidelines that have not otherwise been identified. The main focus of the third task was to modify the individual ACRDR guidelines generated to date to ensure that they are suitable for the intended nuclear power plant (NPP) control station system application. The goal of the fourth task was to develop human factors guidelines for two human-system interface categories that are missing from the current ACRDR guidelines document. During the first task those areas in NUREG-0700 that are not addressed by the ACRDR guidelines document were identified, the areas were subsequently reviewed against six recent industry human factors engineering review guidelines, and the NUREG-0700 guidelines were updated as necessary. In the second task 13 general categories of human-system interface guidelines that are either missing from or not adequately addressed by the ACRDR document were discovered. An approach was derived for the development of new ACRDR guidelines, a preliminary assessment of the available sources that may be useful in the creation of new guidelines and their applicability to the identified human-system interface categories was performed, and an estimate was made of the amount of time and level of effort required to complete the development of needed new ACRDR guidelines. During the third task those NPP control station systems to which the NUREG-0700 and ACRDR guidelines apply were identified, matrices of such

  16. Advanced control room design review guidelines: Integration of the NUREG-0700 guidelines and development of new human-system interface guidelines

    International Nuclear Information System (INIS)

    Carter, R.J.

    1997-07-01

    This report documents the work conducted in four tasks of the Nuclear Regulatory Commission (NRC) project entitled Review Criteria for Human Factors Aspects of Advanced Controls and Instrumentation. The purpose of the first task was to integrate the applicable sections of NUREG-0700 into the advanced control room design review (ACRDR) guidelines to ensure that all applicable guidelines are together in one document and conveniently accessible to users. The primary objective of the second task was to formulate a strategy for the development of new ACRDR guidelines that have not otherwise been identified. The main focus of the third task was to modify the individual ACRDR guidelines generated to date to ensure that they are suitable for the intended nuclear power plant (NPP) control station system application. The goal of the fourth task was to develop human factors guidelines for two human-system interface categories that are missing from the current ACRDR guidelines document. During the first task those areas in NUREG-0700 that are not addressed by the ACRDR guidelines document were identified, the areas were subsequently reviewed against six recent industry human factors engineering review guidelines, and the NUREG-0700 guidelines were updated as necessary. In the second task 13 general categories of human-system interface guidelines that are either missing from or not adequately addressed by the ACRDR document were discovered. An approach was derived for the development of new ACRDR guidelines, a preliminary assessment of the available sources that may be useful in the creation of new guidelines and their applicability to the identified human-system interface categories was performed, and an estimate was made of the amount of time and level of effort required to complete the development of needed new ACRDR guidelines. During the third task those NPP control station systems to which the NUREG-0700 and ACRDR guidelines apply were identified, matrices of such

  17. 10 CFR 960.4-2 - Technical guidelines.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Technical guidelines. 960.4-2 Section 960.4-2 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Postclosure Guidelines § 960.4-2 Technical guidelines. The technical guidelines in this subpart...

  18. 10 CFR 960.5-2 - Technical guidelines.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Technical guidelines. 960.5-2 Section 960.5-2 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Preclosure Guidelines § 960.5-2 Technical guidelines. The technical guidelines in this subpart set...

  19. European Society of Endocrinology Clinical Practice Guideline for long-term follow-up of patients operated on for a phaeochromocytoma or a paraganglioma.

    Science.gov (United States)

    Plouin, P F; Amar, L; Dekkers, O M; Fassnacht, M; Gimenez-Roqueplo, A P; Lenders, J W M; Lussey-Lepoutre, C; Steichen, O

    2016-05-01

    Phaeochromocytomas and paragangliomas (PPGLs) are rare neuroendocrine tumours. Standard treatment is surgical resection. Following complete resection of the primary tumour, patients with PPGL are at risk of developing new tumoural events. The present guideline aims to propose standardised clinical care of long-term follow-up in patients operated on for a PPGL. The guideline has been developed by The European Society of Endocrinology and based on the Grading of Recommendations Assessment, Development and Evaluation (GRADE) principles. We performed a systematic review of the literature and analysed the European Network for the Study of Adrenal Tumours (ENS@T) database. The risk of new events persisted in the long term and was higher for patients with genetic or syndromic diseases. Follow-up in the published cohorts and in the ENS@T database was neither standardised nor exhaustive, resulting in a risk of follow-up bias and in low statistical power beyond 10 years after complete surgery. To inform patients and care providers in this context of low-quality evidence, the Guideline Working Group therefore prepared recommendations on the basis of expert consensus. Key recommendations are the following: we recommend that all patients with PPGL be considered for genetic testing; we recommend assaying plasma or urinary metanephrines every year to screen for local or metastatic recurrences or new tumours; and we suggest follow-up for at least 10 years in all patients operated on for a PPGL. High-risk patients (young patients and those with a genetic disease, a large tumour and/or a paraganglioma) should be offered lifelong annual follow-up. © 2016 European Society of Endocrinology.

  20. BWR water chemistry guidelines and PWR primary water chemistry guidelines in Japan – Purpose and technical background

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, Hirotaka, E-mail: kawamuh@criepi.denken.or.jp [Central Research Institute of Electric Power Industry (Japan); Hirano, Hideo [Central Research Institute of Electric Power Industry (Japan); Katsumura, Yousuke [University of Tokyo (Japan); Uchida, Shunsuke [Tohoku University (Japan); Mizuno, Takayuki [Mie University (Japan); Kitajima, Hideaki; Tsuzuki, Yasuo [Japan Nuclear Safety Institute (Japan); Terachi, Takumi [Institute of Nuclear Safety System, Inc. (Japan); Nagase, Makoto; Usui, Naoshi [Hitachi-GE Nuclear Energy, Ltd. (Japan); Takagi, Junichi; Urata, Hidehiro [Toshiba Corporation (Japan); Shoda, Yasuhiko; Nishimura, Takao [Mitsubishi Heavy Industry, Ltd. (Japan)

    2016-12-01

    Highlights: • Framework of BWR/PWR water chemistry Guidelines in Japan are presented. • Guideline necessity, definitions, philosophy and technical background are mentioned. • Some guideline settings for control parameters and recommendations are explaines. • Chemistry strategy is also mentioned. - Abstract: After 40 years of light water reactor (LWR) operations in Japan, the sustainable development of water chemistry technologies has aimed to ensure the highest coolant system component integrity and fuel reliability performance for maintaining LWRs in the world; additionally, it aimed to achieve an excellent dose rate reduction. Although reasonable control and diagnostic parameters are utilized by each boiling water reactor (BWR) and pressurized water reactor (PWR) owner, it is recognized that specific values are not shared among everyone involved. To ensure the reliability of BWR and PWR operation and maintenance, relevant members of the Atomic Energy Society of Japan (AESJ) decided to establish guidelines for water chemistry. The Japanese BWR and PWR water chemistry guidelines provide strategies to improve material and fuel reliability performance as well as to reduce dosing rates. The guidelines also provide reasonable “control values”, “diagnostic values” and “action levels” for multiple parameters, and they stipulate responses when these levels are exceeded. Specifically, “conditioning parameters” are adopted in the Japanese PWR primary water chemistry guidelines. Good practices for operational conditions are also discussed with reference to long-term experience. This paper presents the purpose, technical background and framework of the preliminary water chemistry guidelines for Japanese BWRs and PWRs. It is expected that the guidelines will be helpful as an introduction to achieve safety and reliability during operations.

  1. Guidelines for the operation and closure of deep geological repositories for the disposal of high level and alpha bearing wastes

    International Nuclear Information System (INIS)

    1991-10-01

    The operation and closure of a deep geological repository for the disposal of high level and alpha bearing wastes is a long term project involving many disciplines. This unique combination of nuclear operations in a deep underground location will require careful planning by the operating organization. The basic purpose of the operation stage of the deep repository is to ensure the safe disposal of the radioactive wastes. The purpose of the closure stage is to ensure that the wastes are safely isolated from the biosphere, and that the surface region can be returned to normal use. During these two stages of operation and closure, it is essential that both workers and the public are safely protected from radiation hazards, and that workers are protected from the hazards of working underground. For these periods of the repository, it is essential to carry out monitoring for purposes of radiological protection, and to continue testing and investigations to provide data for repository performance confirmation and for final safety assessment. Over the lengthy stages of operation and closure, there will be substantial feedback of experience and generation of site data. These will lead both to improved quality of operation and a better understanding of the site characteristics, thereby enhancing the confidence in the ability of the repository system to isolate the waste and protect future generations. 15 refs

  2. Final guidelines for an Environmental Impact Statement on the proposed construction and operation of a replacement nuclear research reactor at the Lucas Heights Science and Technology Centre

    International Nuclear Information System (INIS)

    1998-01-01

    These guidelines are based on the requirements of paragraphs 4.1 and 4.3 of the Administrative Procedures under the Commonwealth Environment Protection (Impact of Proposals) Act 1974 (EPIP Act).The Australian Nuclear Science and Technology Organisation (ANSTO) has been designated as proponent under the EPIP Act in relation to the proposed replacement nuclear research reactor at the Lucas Heights Science and Technology Centre (LHSTC). The term 'environment' refers to all aspects of the surroundings of human beings, whether affecting human beings as individuals or in social groupings. It includes the natural environment, the built environment, and social aspects of our surroundings. The definition covers such factors as air, water, soils, flora,fauna, buildings, roads, employment, hazards and risks, and safety. As set out in the guidelines, the scope of this assessment shall encompass those issues and alternatives directly related to the construction and operation of a replacement nuclear research reactor at the LHSTC. The EIS will need to make clear the site selection criteria used, and the basis, in assessing Lucas Heights as being suitable for a new reactor. While the EIS will address all aspects of the construction and operation of a replacement nuclear research reactor, it will not address issues associated with the treatment of spent nuclear fuel rods from the existing High Flux Australian Reactor (HIFAR facility). The EIS will also address issues associated with the eventual decommissioning of the proposed replacement reactor, and eventual decommissioning of the existing HIFAR facility

  3. The Japanese Society of Pathology Guidelines on the handling of pathological tissue samples for genomic research: Standard operating procedures based on empirical analyses.

    Science.gov (United States)

    Kanai, Yae; Nishihara, Hiroshi; Miyagi, Yohei; Tsuruyama, Tatsuhiro; Taguchi, Kenichi; Katoh, Hiroto; Takeuchi, Tomoyo; Gotoh, Masahiro; Kuramoto, Junko; Arai, Eri; Ojima, Hidenori; Shibuya, Ayako; Yoshida, Teruhiko; Akahane, Toshiaki; Kasajima, Rika; Morita, Kei-Ichi; Inazawa, Johji; Sasaki, Takeshi; Fukayama, Masashi; Oda, Yoshinao

    2018-02-01

    Genome research using appropriately collected pathological tissue samples is expected to yield breakthroughs in the development of biomarkers and identification of therapeutic targets for diseases such as cancers. In this connection, the Japanese Society of Pathology (JSP) has developed "The JSP Guidelines on the Handling of Pathological Tissue Samples for Genomic Research" based on an abundance of data from empirical analyses of tissue samples collected and stored under various conditions. Tissue samples should be collected from appropriate sites within surgically resected specimens, without disturbing the features on which pathological diagnosis is based, while avoiding bleeding or necrotic foci. They should be collected as soon as possible after resection: at the latest within about 3 h of storage at 4°C. Preferably, snap-frozen samples should be stored in liquid nitrogen (about -180°C) until use. When intending to use genomic DNA extracted from formalin-fixed paraffin-embedded tissue, 10% neutral buffered formalin should be used. Insufficient fixation and overfixation must both be avoided. We hope that pathologists, clinicians, clinical laboratory technicians and biobank operators will come to master the handling of pathological tissue samples based on the standard operating procedures in these Guidelines to yield results that will assist in the realization of genomic medicine. © 2018 The Authors. Pathology International published by Japanese Society of Pathology and John Wiley & Sons Australia, Ltd.

  4. Energy-optimised planning and operation of UPS installations. Guidelines for planners and operators; Energieoptimierte Planung und Betrieb von USV-Anlagen. Ein Leitfaden fuer Planer und Betreiber

    Energy Technology Data Exchange (ETDEWEB)

    Neyer, A.; Schnyder, G.; Mauchle, P.

    2004-09-15

    This comprehensive brochure elaborated for the Swiss Federal Office of Energy (SFOE) is one of a set of nine reports that provide an overall review of the energy-efficiency of UPS systems. This brochure for planners and operators of UPS installations takes a look at how UPS installations can be optimised in order to reduce losses and to provide optimal operation as far as energy efficiency is concerned. The brochure explains the various types of UPS systems and their use and gives tips on ordering. Operational modes, load considerations, system configuration and specifications for putting to tender are looked at, as are the requirements to be placed on the systems for optimal operation. Basic rules for planning activities are quoted. Finally, rotating UPS installations and dynamic energy storage are briefly looked at. The paper is completed with checklists and a quality/energy-matrix.

  5. The Experimental Regional Ensemble Forecast System (ExREF): Its Use in NWS Forecast Operations and Preliminary Verification

    Science.gov (United States)

    Reynolds, David; Rasch, William; Kozlowski, Daniel; Burks, Jason; Zavodsky, Bradley; Bernardet, Ligia; Jankov, Isidora; Albers, Steve

    2014-01-01

    The Experimental Regional Ensemble Forecast (ExREF) system is a tool for the development and testing of new Numerical Weather Prediction (NWP) methodologies. ExREF is run in near-realtime by the Global Systems Division (GSD) of the NOAA Earth System Research Laboratory (ESRL) and its products are made available through a website, an ftp site, and via the Unidata Local Data Manager (LDM). The ExREF domain covers most of North America and has 9-km horizontal grid spacing. The ensemble has eight members, all employing WRF-ARW. The ensemble uses a variety of initial conditions from LAPS and the Global Forecasting System (GFS) and multiple boundary conditions from the GFS ensemble. Additionally, a diversity of physical parameterizations is used to increase ensemble spread and to account for the uncertainty in forecasting extreme precipitation events. ExREF has been a component of the Hydrometeorology Testbed (HMT) NWP suite in the 2012-2013 and 2013-2014 winters. A smaller domain covering just the West Coast was created to minimize band-width consumption for the NWS. This smaller domain has and is being distributed to the National Weather Service (NWS) Weather Forecast Office and California Nevada River Forecast Center in Sacramento, California, where it is ingested into the Advanced Weather Interactive Processing System (AWIPS I and II) to provide guidance on the forecasting of extreme precipitation events. This paper will review the cooperative effort employed by NOAA ESRL, NASA SPoRT (Short-term Prediction Research and Transition Center), and the NWS to facilitate the ingest and display of ExREF data utilizing the AWIPS I and II D2D and GFE (Graphical Software Editor) software. Within GFE is a very useful verification software package called BoiVer that allows the NWS to utilize the River Forecast Center's 4 km gridded QPE to compare with all operational NWP models 6-hr QPF along with the ExREF mean 6-hr QPF so the forecasters can build confidence in the use of the

  6. The effect of implementing a new guideline and operative pro forma on the detection and management of third- and fourth-degree perineal tears

    Directory of Open Access Journals (Sweden)

    Cornell K

    2016-05-01

    Full Text Available Kristin Cornell,1 Alison De Souza,2 Mark Tacey,3 David M Long,4 Mayooran Veerasingham5 1Department of Obstetrics and Gynaecology, The Northern Hospital, Epping, VIC, 2Department of Urogynecology, Mercy Hospital for Women, Melbourne, VIC, 3Northern Clinical Research Centre, The Northern Hospital and Department of Medicine, University of Melbourne, Melbourne, VIC, 4Department of Emergency Medicine, The Austin Hospital, Melbourne, VIC, 5The Department of Obstetrics and Gynaecology, Ipswich General Hospital, Ipswich, QLD, Australia Background: Obstetric anal sphincter injury (OASI is a serious complication of vaginal births, resulting in possible long-term consequences such as incontinence and pain. Adequate detection and management of these injuries is vital in minimizing the impact they have on women. Aim: To assess the rates of detection, management, and outcomes of OASI before and after the implementation of a new clinical practice guideline and operative pro forma. Materials and methods: A 12-month audit of the incidence, management, and outcomes of OASI was conducted in 2009. An operative pro forma and practice guideline were implemented in 2010 followed by a further audit undertaken between 2010 and 2012. Statistical analysis was performed to determine any significant change in practice. Results: The distribution of risk factors for OASI including primiparity, birthweight, and type of vaginal delivery was similar between the two audited groups. After implementation of the pro forma, the reported incidence of OASI increased from 1.62% to 3.1% (P=0.004. Significant changes in management included an increase in the use of recommended suture material (48% vs 80%, P=0.002, postoperative antibiotics (78% vs 99%, P=0.001, postoperative catheterization (52% vs 90%, P<0.001, and inpatient physiotherapy consultations (44% vs 97%, P=<0.001. An increase was seen in women attending their 6-week follow-up appointment (33% vs 54% P=0.058; however, this was

  7. Guidelines for the Use of Mathematics in Operational Area-Wide Integrated Pest Management Programmes Using the Sterile Insect Technique with a Special Focus on Tephritid Fruit Flies

    International Nuclear Information System (INIS)

    Barclay, H.L.; Enkerlin, W.R.; Manoukis, N.C.; Reyes-Flores, J.

    2016-01-01

    This guideline attempts to assist managers in the use of mathematics in area-wide Integrated Pest Management (AW-IPM) programmes using the Sterile Insect Technique (SIT). It describes mathematical tools that can be used at different stages of suppression/eradication programmes. For instance, it provides simple methods for calculating the various quantities of sterile insects required in the intervention area so that more realistic sterile: fertile rates to suppress pest populations can be achieved. The calculations, for the most part, only involve high school mathematics and can be done easily with small portable computers or calculators. The guideline is intended to be a reference book, to be consulted when necessary. As such, any particular AW-IPM programme using the SIT will probably only need certain sections, and much of the book can be ignored if that is the case. For example, if the intervention area is relatively small and well isolated, then the section on dispersal can safely be ignored, as the boundedness of the area means that dispersal should not be a problem, and so the section on diffusion equations can be ignored. An overview is given in each chapter to try to let the programme manager make a decision about where to put the programme efforts. On the other hand, most SIT programmes have an information system (many of them based on GIS) that produces reliable profiles of historic information. Based on the results of past activities they describe what has happened in the last days or weeks but usually do not explain, or barely explain, what is expected in the following days or weeks. Current AW-IPM progammes using the SIT have produced over many years a vast amount of every-day data from the field operations and from the mass rearing facility and packing and sterile insect releasing centres. With the help of this guideline, that information can be used to develop predictive models for their particular conditions to better plan control measures.

  8. Scoliosis Research Society (SRS) Criteria and Society of Scoliosis Orthopaedic and Rehabilitation Treatment (SOSORT) 2008 Guidelines in Non-Operative Treatment of Idiopathic Scoliosis.

    Science.gov (United States)

    Korbel, Krzysztof; Kozinoga, Mateusz; Stoliński, Łukasz; Kotwicki, Tomasz

    2014-07-28

    According to the Scoliosis Research Society (SRS), idiopathic scoliosis (IS) is a curvature of more than 10° Cobb angle, affecting 2-3% of pediatric population. Idiopathic scoliosis accounts for 80% of all scoliosis cases. Non-operative principles in the therapy of idiopathic scoliosis, including Scoliosis Research Society (SRS) criteria and guidelines proposed by the experts of the Society on Scoliosis Orthopedic and Rehabilitation Treatment (SOSORTS) were presented. The possibility to carry out quality of life assessments in a conservative procedure was also demonstrated. Based on the natural history of idiopathic scoliosis, SRS criteria, SOSORT 2008 experts' opinion and the knowledge of the possibilities of psychological assessment of conservative IS treatment, rules were proposed regarding nonsurgical IS therapy procedures, with special consideration being paid to the proper treatment start time (age, Risser test, biological maturity, Cobb angle), possibility of curvature progression, the importance of physiotherapy and psychological assessment. The knowledge of SRS criteria and SOSORT guidelines regarding the conservative treatment of IS are essential for proper treatment (the right time to start treatment), and supports establishment of interdisciplinary treatment teams, consisting of a physician, a physiotherapist, an orthopedic technician and a psychologist.

  9. Quality Guidelines

    Science.gov (United States)

    ... this page: https://medlineplus.gov/criteria.html MedlinePlus Quality Guidelines To use the sharing features on this ... materials must also meet our existing quality guidelines. Quality, authority and accuracy of health content The organization's ...

  10. Development and Preliminary Validation of a Comprehensive Questionnaire to Assess Women’s Knowledge and Perception of the Current Weight Gain Guidelines during Pregnancy

    Directory of Open Access Journals (Sweden)

    Holly Ockenden

    2016-11-01

    Full Text Available The aim of this study was to develop and validate an electronic questionnaire, the Electronic Maternal Health Survey (EMat Health Survey, related to women’s knowledge and perceptions of the current gestational weight gain guidelines (GWG, as well as pregnancy-related health behaviours. Constructs addressed within the questionnaire include self-efficacy, locus of control, perceived barriers, and facilitators of physical activity and diet, outcome expectations, social environment and health practices. Content validity was examined using an expert panel (n = 7 and pilot testing items in a small sample (n = 5 of pregnant women and recent mothers (target population. Test re-test reliability was assessed among a sample (n = 71 of the target population. Reliability scores were calculated for all constructs (r and intra-class correlation coefficients (ICC, those with a score of >0.5 were considered acceptable. The content validity of the questionnaire reflects the degree to which all relevant components of excessive GWG risk in women are included. Strong test-retest reliability was found in the current study, indicating that responses to the questionnaire were reliable in this population. The EMat Health Survey adds to the growing body of literature on maternal health and gestational weight gain by providing the first comprehensive questionnaire that can be self-administered and remotely accessed. The questionnaire can be completed in 15–25 min and collects useful data on various social determinants of health and GWG as well as associated health behaviours. This online tool may assist researchers by providing them with a platform to collect useful information in developing and tailoring interventions to better support women in achieving recommended weight gain targets in pregnancy.

  11. ASSET guidelines

    International Nuclear Information System (INIS)

    1990-11-01

    The IAEA Assessment of Safety Significant Events Team (ASSET) Service provides advice and assistance to Member States to enhance the overall level of plant safety while dealing with the policy of prevention of incidents at nuclear power plants. The ASSET programme, initiated in 1986, is not restricted to any particular group of Member States, whether developing or industrialized, but is available to all countries with nuclear power plants in operation or approaching commercial operation. The IAEA Safety Series publications form common basis for the ASSET reviews, including the Nuclear Safety Standards (NUSS) and the Basic Safety Principles (Recommendations of Safety Series No. 75-INSAG-3). The ASSET Guidelines provide overall guidance for the experts to ensure the consistency and comprehensiveness of their review of incident investigations. Additional guidance and reference material is provided by the IAEA to complement the expertise of the ASSET members. ASSET reviews accept different approaches that contribute to ensuring an effective prevention of incidents at plants. Suggestions are offered to enhance plant safety performance. Commendable good practices are identified and generic lessons are communicated to other plants, where relevant, for long term improvement

  12. 10 CFR 960.5-1 - System guidelines.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false System guidelines. 960.5-1 Section 960.5-1 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Preclosure Guidelines § 960.5-1 System guidelines. (a) Qualifying conditions—(1) Preclosure...

  13. SU-F-P-54: Guidelines to Check Image Registration QA of a Clinical Deformation Registration Software: A Single Institution Preliminary Study

    Energy Technology Data Exchange (ETDEWEB)

    Gill, G; Souri, S; Rea, A; Chen, Y; Antone, J; Qian, X; Riegel, A; Taylor, P; Marrero, M; Diaz, F; Cao, Y; Jamshidi, A; Klein, E [Northwell Health, Lake Success, NY (United States); Barley, S; Sorell, V; Karangelis, G [Oncology Systems Limited, Longbow Close, Shrewsbury SY1 3GZ (United Kingdom); Button, T [Stony Brook University Hospital, Stony Brook, NY (United States)

    2016-06-15

    Purpose: The objective of this study is to verify and analyze the accuracy of a clinical deformable image registration (DIR) software. Methods: To test clinical DIR software qualitatively and quantitatively, we focused on lung radiotherapy and analyzed a single (Lung) patient CT scan. Artificial anatomical changes were applied to account for daily variations during the course of treatment including the planning target volume (PTV) and organs at risk (OAR). The primary CT (pCT) and the structure set (pST) was deformed with commercial tool (ImSimQA-Oncology Systems Limited) and after artificial deformation (dCT and dST) sent to another commercial tool (VelocityAI-Varian Medical Systems). In Velocity, the deformed CT and structures (dCT and dST) were inversely deformed back to original primary CT (dbpCT and dbpST). We compared the dbpST and pST structure sets using similarity metrics. Furthermore, a binary deformation field vector (BDF) was created and sent to ImSimQA software for comparison with known “ground truth” deformation vector fields (DVF). Results: An image similarity comparison was made by using “ground truth” DVF and “deformed output” BDF with an output of normalized “cross correlation (CC)” and “mutual information (MI)” in ImSimQA software. Results for the lung case were MI=0.66 and CC=0.99. The artificial structure deformation in both pST and dbpST was analyzed using DICE coefficient, mean distance to conformity (MDC) and deformation field error volume histogram (DFEVH) by comparing them before and after inverse deformation. We have noticed inadequate structure match for CTV, ITV and PTV due to close proximity of heart and overall affected by lung expansion. Conclusion: We have seen similarity between pCT and dbpCT but not so well between pST and dbpST, because of inadequate structure deformation in clinical DIR system. This system based quality assurance test will prepare us for adopting the guidelines of upcoming AAPM task group 132

  14. SU-F-P-54: Guidelines to Check Image Registration QA of a Clinical Deformation Registration Software: A Single Institution Preliminary Study

    International Nuclear Information System (INIS)

    Gill, G; Souri, S; Rea, A; Chen, Y; Antone, J; Qian, X; Riegel, A; Taylor, P; Marrero, M; Diaz, F; Cao, Y; Jamshidi, A; Klein, E; Barley, S; Sorell, V; Karangelis, G; Button, T

    2016-01-01

    Purpose: The objective of this study is to verify and analyze the accuracy of a clinical deformable image registration (DIR) software. Methods: To test clinical DIR software qualitatively and quantitatively, we focused on lung radiotherapy and analyzed a single (Lung) patient CT scan. Artificial anatomical changes were applied to account for daily variations during the course of treatment including the planning target volume (PTV) and organs at risk (OAR). The primary CT (pCT) and the structure set (pST) was deformed with commercial tool (ImSimQA-Oncology Systems Limited) and after artificial deformation (dCT and dST) sent to another commercial tool (VelocityAI-Varian Medical Systems). In Velocity, the deformed CT and structures (dCT and dST) were inversely deformed back to original primary CT (dbpCT and dbpST). We compared the dbpST and pST structure sets using similarity metrics. Furthermore, a binary deformation field vector (BDF) was created and sent to ImSimQA software for comparison with known “ground truth” deformation vector fields (DVF). Results: An image similarity comparison was made by using “ground truth” DVF and “deformed output” BDF with an output of normalized “cross correlation (CC)” and “mutual information (MI)” in ImSimQA software. Results for the lung case were MI=0.66 and CC=0.99. The artificial structure deformation in both pST and dbpST was analyzed using DICE coefficient, mean distance to conformity (MDC) and deformation field error volume histogram (DFEVH) by comparing them before and after inverse deformation. We have noticed inadequate structure match for CTV, ITV and PTV due to close proximity of heart and overall affected by lung expansion. Conclusion: We have seen similarity between pCT and dbpCT but not so well between pST and dbpST, because of inadequate structure deformation in clinical DIR system. This system based quality assurance test will prepare us for adopting the guidelines of upcoming AAPM task group 132

  15. Preliminary volcanic hazards evaluation for Los Alamos National Laboratory Facilities and Operations : current state of knowledge and proposed path forward

    Energy Technology Data Exchange (ETDEWEB)

    Keating, Gordon N.; Schultz-Fellenz, Emily S.; Miller, Elizabeth D.

    2010-09-01

    The integration of available information on the volcanic history of the region surrounding Los Alamos National Laboratory indicates that the Laboratory is at risk from volcanic hazards. Volcanism in the vicinity of the Laboratory is unlikely within the lifetime of the facility (ca. 50–100 years) but cannot be ruled out. This evaluation provides a preliminary estimate of recurrence rates for volcanic activity. If further assessment of the hazard is deemed beneficial to reduce risk uncertainty, the next step would be to convene a formal probabilistic volcanic hazards assessment.

  16. Relationships between post operative pain management and short term functional mobility in total knee arthroplasty patients with a femoral nerve catheter: A preliminary study

    Directory of Open Access Journals (Sweden)

    Ward Sarah

    2011-02-01

    Full Text Available Abstract Background Effective pain management following total knee arthroplasty (TKA is fundamental in achieving positive rehabilitation outcomes. The purpose of our study was to investigate post operative pain management in relation to short term functional mobility in an intervention group receiving concomitant use of an IV narcotic PCA and a continuous infusion of local anaesthetic via a femoral nerve catheter (CFNC, compared to a group receiving narcotic PCA alone. This was a preliminary study conducted to establish an appropriate design for a larger investigative study. Methods A prospective design was used to measure the effect of a CFNC on post operative pain management and functional mobility prior to hospital discharge. The amount of fentanyl used, pain and nausea scores, timed up and go (TUG tests and active range of knee movement (AROM were used to compare a CFNC and supplemental narcotic patient controlled analgesia (PCA group (n = 27 with a PCA only group (n = 25. Results The CFNC group used significantly less fentanyl than the PCA only group (p s = .505 p s = .529 p s = .328, p = .034 Conclusions In this small preliminary study improved TUG performance at Day 4 post op was not influenced by the use of a CFNC but was positively correlated with male gender, preoperative performance, time elapsed since last oral analgesia and pain score. However AROM was decreased in the CFNC group suggesting further research on the relationship between CFNCs, local anaesthetic concentration and quadriceps strength should be incorporated in the follow up study's design.

  17. PWR water chemistry controls: a perspective on industry initiatives and trends relative to operating experience and the EPRI PWR water chemistry guidelines

    International Nuclear Information System (INIS)

    Fruzzetti, K.; Choi, S.; Haas, C.; Pender, M.; Perkins, D.

    2010-01-01

    An effective PWR water chemistry control program must address the following goals: Minimize materials degradation (e.g., PWSCC, corrosion of fuel, corrosion damage of steam generator (SG) tubes); Maintain fuel integrity and good performance; Minimize corrosion product transport (e.g., transport and deposition on the fuel, transport into the SGs where it can foul tube surfaces and create crevice environments for the concentration of corrosive impurities); Minimize dose rates. Water chemistry control must be optimized to provide overall improvement considering the sometimes variant constraints of the goals listed above. New technologies are developed for continued mitigation of materials degradation, continued fuel integrity and good performance, continued reduction of corrosion product transport, and continued minimization of plant dose rates. The EPRI chemistry program, in coordination with other EPRI programs, strives to improve these areas through application of chemistry initiatives, focusing on these goals. This paper highlights the major initiatives and issues with respect to PWR primary and secondary system chemistry and outlines the recent, on-going, and proposed work to effectively address them. These initiatives are presented in light of recent operating experience, as derived from EPRI's PWR chemistry monitoring and assessment program, and EPRI's water chemistry guidelines. (author)

  18. Preliminary results of a pilot study on the behaviour of nuclear power station operating staff in simulated faults

    International Nuclear Information System (INIS)

    Reinartz, S.J.

    1984-01-01

    The necessity of distinguishing the effect of a fault and the stabilizing effects of the automatic control devices leads to operating staff being supported by suitable configuration of the control room and work aids. The aim of the study consists of having a better understanding of how control room operating staff control a fault and how they carry out the problem solving tasks of fault recognition, diagnosis and compensation. These tasks differ from the normal daily tasks and operators only have to do them rarely. The study is intended to examine what is necessary so that operators can do their job: what information they have to have about plant conditions and how this should be shown: trend information of digital display, conventional indication or VDU screens. (orig./DG) [de

  19. Preliminary assessment of the operating performance and calibration of rectilinear scanners and dose calibrators in Rio de Janeiro - Brazil

    International Nuclear Information System (INIS)

    Mendes, L.; Wegst, A.

    1983-01-01

    Thirty rectilinear scanners and ten dose calibrators were tested for a variety of operating conditions. The test for rectilinear scanners were based on image quality obtained with phantoms of the brain, liver (Williams phantom) and thyroid. The parameters investigated specifically for rectilinear scanners included those under direct control of the operator, such as proper setting of the focal distance, the velocity, the photopeak calibration, contrast correct collimator, line spacing, and background count. (E.G.) [pt

  20. Stibine/arsine monitoring during EV operation: summary report on preliminary tests at ANL and at LILCO

    Energy Technology Data Exchange (ETDEWEB)

    Loutfy, R.O.; Graczyk, D.G.; Varma, R.; Hayes, E.R.; Williams, F.L.; Yao, N.P.

    1981-02-01

    A series of tests was performed to monitor the evolution and dispersal of stibine and arsine from the lead-acid propulsion batteries in three different Electra-Van Model 600 vehicles operated by Argonne National Laboratory (ANL) and by the Long Island Lighting Company (LILCO). Ambient air was sampled at several locations inside the vehicles and in the garages where testing was done during charge, equalization charge, and on-the-road discharge operations. In addition, direct sampling of cell off-gases was performed with the ANL van. Interpretation of the individual test results was carried out in the context of vehicle characteristics, sampling protocol, and operating conditions. The test results demonstrated that under the test conditions only small concentrations of stibine and arsine accumulated in occupiable work areas. Measured concentrations in the vehicles and in the garages never exceeded 25% of the Threshold Limit Value-Time Weighted Average (TLV-TWA) standards. A threshold voltage for hydride production, at about 2.45 V per cell, was reflected in the results of the experiments performed during charging of the batteries. Hydride evolution rates were lower during equalization charge than during the overcharge portion of a charge cycle when the on-board charger was used in a normal operating mode. A delayed release of the metal hydrides from the battery cells was observed during on-the-road operation of the vehicles. The implications of these observations for electric vehicle (EV) operation are discussed. An engineering analysis of the generation and dispersal of the metal hydrides is presented, and equations are derived for estimating minimum ventilation requirements for the EV battery compartment and for garages housing EV operations. Recommendations are made regarding safe handling procedures for battery off-gases, procedures for conducting stibine/arsine monitoring tests and future work.

  1. Preliminary design and estimate of capital and operating costs for a production scale application of laser decontamination technology

    International Nuclear Information System (INIS)

    Pang, Ho-ming; Edelson, M.C.

    1994-01-01

    The application of laser ablation technology to the decontamination of radioactive metals, particularly the surfaces of equipment, is discussed. Included is information related to the design, capital and operating costs, and effectiveness of laser ablation technology, based on commercial excimer and Nd:YAG lasers, for the decontamination of production scale equipment

  2. Preliminary audiologic and peri-operative outcomes of the Sophono™ transcutaneous bone conduction device: A systematic review.

    Science.gov (United States)

    Bezdjian, Aren; Bruijnzeel, Hanneke; Daniel, Sam J; Grolman, Wilko; Thomeer, Hans G X M

    2017-10-01

    To delineate the auditory functional improvement and peri-operative outcomes of the Sophono™ transcutaneous bone conduction device. Eligible articles presenting patients implanted with the Sophono™ were identified through a comprehensive search of PubMed and Embase electronic databases. All relevant articles were reviewed to justify inclusion independently by 2 authors. Studies that successfully passed critical appraisal for directness of evidence and risk of bias were included. From a total of 125 articles, 8 studies encompassing 86 patients using 99 implants were selected. Most patients (79.1%) were children. Ear atresia (67.5%) was the most frequently reported indication for Sophono™ implantation. Overall pure tone average auditory improvement was 31.10 (±8.29) decibel. During a mean follow-up time of 12.48 months, 25 patients (29%) presented with post-operative complications from which 3 were deemed as serious implant-related adverse events (3.5%). The Sophono™ transcutaneous bone conduction device shows promising functional improvement, no intra-operative complications and minor post-operative skin related complications. If suitable, the device could be a proposed solution for the rehabilitation of hearing in children meeting eligibility criteria. A wearing schedule must be implemented in order to reduce magnet-related skin complications. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Summary guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Halsnaes, K.; Painuly, J.P.; Turkson, J.; Meyer, H.J.; Markandya, A.

    1999-09-01

    This document is a summary version of the methodological guidelines for climate change mitigation assessment developed as part of the Global Environment Facility (GEF) project Economics of Greenhouse Gas Limitations; Methodological Guidelines. The objectives of this project have been to develop a methodology, an implementing framework and a reporting system which countries can use in the construction of national climate change mitigation policies and in meeting their future reporting obligations under the FCCC. The methodological framework developed in the Methodological Guidelines covers key economic concepts, scenario building, modelling tools and common assumptions. It was used by several country studies included in the project. (au) 13 refs.

  4. Operation and monitoring guidelines and the development of a screening tool for irrigating with coal mine water in Mpumalanga Province, South Africa

    Energy Technology Data Exchange (ETDEWEB)

    Vermeulen, D.; Usher, B. [University of Free State, Bloemfontein (South Africa). Institute of Groundwater Studies

    2009-07-15

    It is predicted that vast volumes of impacted mine water will be produced by mining activities in the Mpumalanga coalfields of South Africa. The potential environmental impact of this excess water is of great concern in a water-scarce country like South Africa. Detailed research has been undertaken over the past number of years onl both undisturbed soils and in coal-mining spoils. These sites range from sandy soils to very clayey soils. The results indicate that many of the soils have considerable attenuation capacities and that over the period of irrigation, a large proportion of the salts are contained in the upper portions of the unsaturated zones below each irrigation pivot. The volumes and quality of water leaching through to the aquifers have been quantified at each site. From these data mixing ratios were calculated in order to determine the effect of the irrigation water on the underlying aquifers. One of the outcomes from this study was to define the conditions under which mine-water irrigation can be implemented and the associated operational and monitoring guidelines that should be followed. These have been based on the findings from this study, the fundamental considerations of mine-water irrigation, the regulatory environment and, as far as possible, the practical implementation of mine-water irrigation as part of optimal mine-water management. In an attempt to standardise decision-making regarding mine-water irrigation, the criteria, data, rules and fundamentals discussed have been combined in a user-friendly tool, called GIMI (Groundwater Impacts from Minewater Irrigation). This tool should assist in the practical implementation of mine-water irrigation as part of optimal mine-water management.

  5. Environmental Impact Analysis Process. Volume 3. Preliminary Final Environmental Impact Statement Construction and Operation of Space Launch Complex 7

    Science.gov (United States)

    1989-10-23

    been introduced into Honda Creek, about two miles north of SLC-6 and about three miles north of the Cypress Ridge, Boathouse Flats, and Vina Terrace...Fish and Wildlife Service, Laguna Niguel Deborah Pontifex, Santa Barbara County APCD, Santa Barbara Jeffrey Harris, Santa Barbara County Resource...on the Channel Islands. In addition, an analysis of acidic deposition into Honda Creek from launch operations was performed. This analysis showed that

  6. Preliminary assessment of nuclear waste transportation cost and risk for operation of the first repository at candidate sites

    International Nuclear Information System (INIS)

    Peterson, R.W.; McSweeney, T.I.; Varadarajan, R.V.; Wilmot, E.L.; Cashwell, J.W.; Joy, D.S.

    1983-01-01

    To support the selection of the first commercial nuclear waste repository site in 1987, environmental analyses of five candidate site locations are currently being performed. The five locations are in the Gulf Interior Region, the Permian Basin, the Paradox Basin, Yucca Mountain and the Hanford reservation. Costs and operational risks associated with the transportation of nuclear wastes to a single repository located in these regions have been calculated for a life-cycle of 26 years

  7. A virtual-reality simulator and force sensation combined catheter operation training system and its preliminary evaluation.

    Science.gov (United States)

    Wang, Yu; Guo, Shuxiang; Tamiya, Takashi; Hirata, Hideyuki; Ishihara, Hidenori; Yin, Xuanchun

    2017-09-01

    Endovascular surgery benefits patients because of its superior short convalescence and lack of damage to healthy tissue. However, such advantages require the operator to be equipped with dexterous skills for catheter manipulation without resulting in collateral damage. To achieve this goal, a training system is in high demand. A training system integrating a VR simulator and a haptic device has been developed within this context. The VR simulator is capable of providing visual cues which assist the novice for safe catheterization. In addition, the haptic device cooperates with VR simulator to apply sensations at the same time. The training system was tested by non-medical subjects over a five days training session. The performance was evaluated in terms of safety criteria and task completion time. The results demonstrate that operation safety is improved by 15.94% and task completion time is cut by 18.80 s maximum. Moreover, according to subjects' reflections, they are more confident in operation. The proposed training system constructs a comprehensive training environment that combines visualization and force sensation. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  8. Interconnection Guidelines

    Science.gov (United States)

    The Interconnection Guidelines provide general guidance on the steps involved with connecting biogas recovery systems to the utility electrical power grid. Interconnection best practices including time and cost estimates are discussed.

  9. Effluent Guidelines

    Science.gov (United States)

    Effluent guidelines are national standards for wastewater discharges to surface waters and municipal sewage treatment plants. We issue the regulations for industrial categories based on the performance of treatment and control technologies.

  10. Ergonomic prevention of musculoskeletal disorders of maintenance workers in the steel industry : Guidelines for the optimum working height of selected maintenance operations

    NARCIS (Netherlands)

    Dul, J.; Bolijn, A.J.; Delleman, N.J.; Hildebrandt, V.H.

    1991-01-01

    In the steel industry musculoskeletal disorders are important determinants of sickness and absenteeism. Prevention of biomechanical risk is therefore important, both for industry and the workers themselves. In this research project, ergonomic guidelines have been developed to reduce high

  11. Guidelines and workbook for assessment of organization and administration of utilities seeking operating license for a nuclear power plant. Guidelines for utility organization and administration plan. Volume 1, Revision 1

    International Nuclear Information System (INIS)

    Thurber, J.A.; Olson, J.; Osborn, R.N.; Sommers, P.; Widrig, R.D.

    1986-09-01

    Volumes 1 and 2 of this report are a partial response to the requirements of Item I.B.1.1 of the ''NRC Action Plan Developed as a Result of the TMI-2 Accident,'' NUREG-0660, and are designed to serve as a basis for replacing the earlier NUREG-0731, ''Guidelines for Utility Management Structure and Technical Resources.'' These Guidelines are intended to provide guidance to the user in preparing a written plan for a proposed nuclear organization and administration. The purpose of the Workbook (Vol. 2) is to guide the NRC reviewer through a systematic review and assessment of a proposed organization and administration. It is the NRC's intention to incorporate these Guidelines and Workbook into a future revision of the Standard Review Plan (SRP), NUREG-0800. However, at this time the report is being published so that the material may be used on a voluntary basis by industry to systematically prepare or evaluate their organization or administration plans. Use of the report by the NRC would not occur until after it has been incorpoarted in the SRP

  12. Water chemistry guidelines for BWRs

    International Nuclear Information System (INIS)

    Bilanin, W.J.; Jones, R.L.; Welty, C.S.

    1984-01-01

    Guidelines for BWR water chemistry control have been prepared by a committee of experienced utility industry personnel sponsored by the BWR Owners Group on IGSCC Research and coordinated by the Electric Power Research Institute. The guidelines are based on extensive plant operational experience and laboratory research data. The purpose of the guidelines is to provide guidance to the electric utility industry on water chemistry control to help reduce corrosion, especially stress corrosion cracking, in boiling water reactors

  13. Evaluating the improvements of the BOLAM meteorological model operational at ISPRA: A case study approach - preliminary results

    Science.gov (United States)

    Mariani, S.; Casaioli, M.; Lastoria, B.; Accadia, C.; Flavoni, S.

    2009-04-01

    The Institute for Environmental Protection and Research - ISPRA (former Agency for Environmental Protection and Technical Services - APAT) runs operationally since 2000 an integrated meteo-marine forecasting chain, named the Hydro-Meteo-Marine Forecasting System (Sistema Idro-Meteo-Mare - SIMM), formed by a cascade of four numerical models, telescoping from the Mediterranean basin to the Venice Lagoon, and initialized by means of analyses and forecasts from the European Centre for Medium-Range Weather Forecasts (ECMWF). The operational integrated system consists of a meteorological model, the parallel verision of BOlogna Limited Area Model (BOLAM), coupled over the Mediterranean sea with a WAve Model (WAM), a high-resolution shallow-water model of the Adriatic and Ionian Sea, namely the Princeton Ocean Model (POM), and a finite-element version of the same model (VL-FEM) on the Venice Lagoon, aimed to forecast the acqua alta events. Recently, the physically based, fully distributed, rainfall-runoff TOPographic Kinematic APproximation and Integration (TOPKAPI) model has been integrated into the system, coupled to BOLAM, over two river basins, located in the central and northeastern part of Italy, respectively. However, at the present time, this latter part of the forecasting chain is not operational and it is used in a research configuration. BOLAM was originally implemented in 2000 onto the Quadrics parallel supercomputer (and for this reason referred to as QBOLAM, as well) and only at the end of 2006 it was ported (together with the other operational marine models of the forecasting chain) onto the Silicon Graphics Inc. (SGI) Altix 8-processor machine. In particular, due to the Quadrics implementation, the Kuo scheme was formerly implemented into QBOLAM for the cumulus convection parameterization. On the contrary, when porting SIMM onto the Altix Linux cluster, it was achievable to implement into QBOLAM the more advanced convection parameterization by Kain and

  14. Residual energy applications program test and operations report

    International Nuclear Information System (INIS)

    Zander, F.H.

    1980-10-01

    Objective of REAP in the recovery of waste heat at US gaseous diffusion plants by 1984. This report contains policy, objective, and guideline suggestions for utilizing the proposed Energy applied Systems Test (EAST) Facility and for managing EAST operations; preliminary design information on facility support equipment and physical plant; and estimates of initial construction costs and staffing requirements for a two-bay, three-shift operation

  15. Development, design, and preliminary operation of a resin-feed processing facility for resin-based HTGR fuels

    International Nuclear Information System (INIS)

    Haas, P.A.; Drago, J.P.; Million, D.L.; Spence, R.D.

    1978-01-01

    Fuel kernels for recycle of 233 U to High-Temperature Gas-Cooled Reactors are prepared by loading carboxylic acid cation exchange resins with uranium and carbonizing at controlled conditions. Resin-feed processing was developed and a facility was designed, installed, and operated to control the kernel size, shape, and composition by processing the resin before adding uranium. The starting materials are commercial cation exchange resins in the sodium form. The size separations are made by vibratory screening of resin slurries in water. After drying in a fluidized bed, the nonspherical particles are separated from spherical particles on vibratory plates of special design. The sized, shape-separated spheres are then rewetted and converted to the hydrogen form. The processing capacity of the equipment tested is equivalent to about 1 kg of uranium per hour and could meet commercial recycle plant requirements without scale-up of the principal process components

  16. BWR emergency procedure guidelines

    International Nuclear Information System (INIS)

    Post, J.S.; Karner, E.F.; Stratman, R.A.

    1984-01-01

    This chapter describes plans for dealing with reactor accidents developed by the Boiling Water Reactor (BWR) Owners' Group in response to post-Three Mile Island US NRC requirements. The devised Emergency Procedure Guidelines (EPGs), applicable to all BWRs, are symptom-based rather than event-based. According to the EPGs, the operator does not need to identify what event is occurring in the plant in order to decide what action to take, but need only observe the symptoms (values and trends of key control parameters) which exist and take appropriate action to control these symptoms. The original objective was to provide reactor operator guidance in responding to a small break loss-of-coolant accident (LOCA), but subsequent revisions have included other types of reactor accidents. Topics considered include the reactor pressure vessel (RPV) control guideline, the primary containment control guideline, the secondary containment control guideline, the radioactivity release control guideline, multiple failures vs. the design basis, safe limits vs. technical specifications, the technical status, licensing, and implementation. The EPGs are based upon maintaining both adequate core cooling and primary containment integrity

  17. Human factors guidelines and methodology in the design of a user computer interface: a case study

    International Nuclear Information System (INIS)

    Richards, R.E.; Gilmore, W.E.; Haney, L.N.

    1986-01-01

    In this case study, human factors personnel were requested to participate in a project team of programmers and operations specialists to design a cathode ray tube (CRT) display system for a complex process control application. This presentation describes the process and benefits obtained by incorporating human factors guidelines and methods in system design. Standard human engineering guidelines and techniques were utilized by the project team. In addition, previously published documents and research findings sponsored by the US Nuclear Regulatory Commission (USNRC) were used. Preliminary tasks involved a review of the draft plant procedures. Then, interviews with operators were conducted to establish the initial information for the displays. These initial requirements were evaluated against existing guidelines and criteria to determine the optimal presentation formats. Detailed steps of the approaches used, design decisions made, and tradeoffs that resulted in the final user acceptable design are discussed. 7 refs., 2 figs

  18. Material characterisation and preliminary mechanical design for the HL-LHC shielded beam screens operating at cryogenic temperatures

    International Nuclear Information System (INIS)

    Garion, C; Dufay-Chanat, L; Koettig, T; Machiocha, W; Morrone, M

    2015-01-01

    The High Luminosity LHC project (HL-LHC) aims at increasing the luminosity (rate of collisions) in the Large Hadron Collider (LHC) experiments by a factor of 10 beyond the original design value (from 300 to 3000 fb -1 ). It relies on new superconducting magnets, installed close to the interaction points, equipped with new beam screen. This component has to ensure the vacuum performance together with shielding the cold mass from physics debris and screening the cold bore cryogenic system from beam induced heating. The beam screen operates in the range 40-60 K whereas the magnet cold bore temperature is 1.9 K. A tungsten-based material is used to absorb the energy of particles. In this paper, measurements of the mechanical and physical properties of such tungsten material are shown at room and cryogenic temperature. In addition, the design and the thermal mechanical behaviour of the beam screen assembly are presented also. They include the heat transfer from the tungsten absorbers to the cooling pipes and the supporting system that has to minimise the heat inleak into the cold mass. The behaviour during a magnet quench is also presented. (paper)

  19. Material characterisation and preliminary mechanical design for the HL-LHC shielded beam screens operating at cryogenic temperatures

    CERN Document Server

    Garion, C; Koettig, T; Machiocha, W; Morrone, M

    2015-01-01

    The High Luminosity LHC project (HL-LHC) aims at increasing the luminosity (rate of collisions) in the Large Hadron Collider (LHC) experiments by a factor of 10 beyond the original design value (from 300 to 3000 fb-1). It relies on new superconducting magnets, installed close to the interaction points, equipped with new beam screen. This component has to ensure the vacuum performance together with shielding the cold mass from physics debris and screening the cold bore cryogenic system from beam induced heating. The beam screen operates in the range 40-60 K whereas the magnet cold bore temperature is 1.9 K. A tungsten-based material is used to absorb the energy of particles. In this paper, measurements of the mechanical and physical properties of such tungsten material are shown at room and cryogenic temperature. In addition, the design and the thermal mechanical behaviour of the beam screen assembly are presented also. They include the heat transfer from the tungsten absorbers to the cooling pipes and the sup...

  20. Material characterisation and preliminary mechanical design for the HL-LHC shielded beam screens operating at cryogenic temperatures.

    Science.gov (United States)

    Garion, C.; Dufay-Chanat, L.; Koettig, T.; Machiocha, W.; Morrone, M.

    2015-12-01

    The High Luminosity LHC project (HL-LHC) aims at increasing the luminosity (rate of collisions) in the Large Hadron Collider (LHC) experiments by a factor of 10 beyond the original design value (from 300 to 3000 fb-1). It relies on new superconducting magnets, installed close to the interaction points, equipped with new beam screen. This component has to ensure the vacuum performance together with shielding the cold mass from physics debris and screening the cold bore cryogenic system from beam induced heating. The beam screen operates in the range 40-60 K whereas the magnet cold bore temperature is 1.9 K. A tungsten-based material is used to absorb the energy of particles. In this paper, measurements of the mechanical and physical properties of such tungsten material are shown at room and cryogenic temperature. In addition, the design and the thermal mechanical behaviour of the beam screen assembly are presented also. They include the heat transfer from the tungsten absorbers to the cooling pipes and the supporting system that has to minimise the heat inleak into the cold mass. The behaviour during a magnet quench is also presented.

  1. Preliminary thermodynamic study of regenerative Otto based cycles with zero NOx emissions operating with adiabatic and polytropic expansion

    International Nuclear Information System (INIS)

    Garcia, Ramon Ferreiro; Carril, Jose Carbia; Romero Gomez, Javier; Romero Gomez, Manuel

    2016-01-01

    of efficient reciprocating internal combustion engines operating at relatively low temperatures.

  2. The Operational MODIS Cloud Optical and Microphysical Property Product: Overview of the Collection 6 Algorithm and Preliminary Results

    Science.gov (United States)

    Platnick, Steven; King, Michael D.; Wind, Galina; Amarasinghe, Nandana; Marchant, Benjamin; Arnold, G. Thomas

    2012-01-01

    Operational Moderate Resolution Imaging Spectroradiometer (MODIS) retrievals of cloud optical and microphysical properties (part of the archived products MOD06 and MYD06, for MODIS Terra and Aqua, respectively) are currently being reprocessed along with other MODIS Atmosphere Team products. The latest "Collection 6" processing stream, which is expected to begin production by summer 2012, includes updates to the previous cloud retrieval algorithm along with new capabilities. The 1 km retrievals, based on well-known solar reflectance techniques, include cloud optical thickness, effective particle radius, and water path, as well as thermodynamic phase derived from a combination of solar and infrared tests. Being both global and of high spatial resolution requires an algorithm that is computationally efficient and can perform over all surface types. Collection 6 additions and enhancements include: (i) absolute effective particle radius retrievals derived separately from the 1.6 and 3.7 !-lm bands (instead of differences relative to the standard 2.1 !-lm retrieval), (ii) comprehensive look-up tables for cloud reflectance and emissivity (no asymptotic theory) with a wind-speed interpolated Cox-Munk BRDF for ocean surfaces, (iii) retrievals for both liquid water and ice phases for each pixel, and a subsequent determination of the phase based, in part, on effective radius retrieval outcomes for the two phases, (iv) new ice cloud radiative models using roughened particles with a specified habit, (v) updated spatially-complete global spectral surface albedo maps derived from MODIS Collection 5, (vi) enhanced pixel-level uncertainty calculations incorporating additional radiative error sources including the MODIS L1 B uncertainty index for assessing band and scene-dependent radiometric uncertainties, (v) and use of a new 1 km cloud top pressure/temperature algorithm (also part of MOD06) for atmospheric corrections and low cloud non-unity emissivity temperature adjustments.

  3. Guidelines for Nordic co-operation concerning nuclear installations in the border areas between Denmark, Finland, Norway and Sweden in respect of nuclear safety conditions

    International Nuclear Information System (INIS)

    1976-01-01

    These Guidelines were established by an Agreement between the Nordic countries. Their purpose is to set up a consultation mechanism between those countries regarding the projected setting up of nuclear facilities near borders which would be likely to affect their respective territories [fr

  4. Investigations of migratory birds during operation of Horns Rev offshore wind farm: Preliminary note of analysis of data from spring 2004

    International Nuclear Information System (INIS)

    Kjaer Christensen, T.; Hounisen, J.P.

    2004-01-01

    In February 1998, the Ministry of the Environment gave Elsam A/S and Eltra A.m.b.a. approval to erect a wind farm, capable of producing 160 MW of electric power, at Horns Rev, west of Blaevandshuk off the west coast of Jutland. Construction activities at Horns Rev started in September 2001 and were finished in summer 2002. The entire project has been organised as a demonstration project to assess the technical, economic and environmental constraints on the future development of electric power production in Danish offshore environments. Within the framework of the environmental programme, bird investigations have been carried out in relation to the risk of collision between birds and wind turbines since 2002. To provide the latest update on the results from the bird investigations, this note presents results compiled during spring 2004 and deals with a preliminary analysis of effects on birds present at Horns Rev during commercial operation of the Horns Rev wind farm. Due to the remoteness of the area it has not been possible to obtain base-line investigation of bird occurrence and behaviour at the wind farm site. (au)

  5. Preliminary results of pre-operative 5-FU, low dose leucovorin (LV), and concurrent radiation therapy (RT) for resectable T3 rectal cancer

    International Nuclear Information System (INIS)

    Grann, Alison; Minsky, Bruce D.; Cohen, Alfred M.; Saltz, Leonard; Kelsen, David P.; Kemeny, Nancy; Ilson, David; Guillem, Jose G.; Paty, Philip B.; Bass, Joanne

    1996-01-01

    PURPOSE: We report the downstaging, acute toxicity, and preliminary local control and survival of pre-op 5-FU, low dose LV, and concurrent RT followed by post-op LV/5-FU for pts with clinically resectable, T3 rectal cancer. MATERIALS AND METHODS: A total of 32 pts (M:26, F:6) were prospectively treated from 12/91-8/95. Eligibility criteria included adequate hematologic indicies, primary adenocarcinoma limited to the pelvis, and T3 disease confirmed by transrectal ultrasound. Twenty five pts were considered clinically to require an APR on initial (pre-treatment) assessment by their operating surgeon. The median age was 56 (range: 24-80), and the median distance from the anal verge was 5.0cm (range: 3-9cm). Pts received 2 monthly cycles (bolus daily X 5) of LV (20mg/m2) and 5-FU (325mg/m2), beginning concurrently with day 1 of RT, followed by surgery 4-5 weeks later. RT included 4680 cGy to the pelvis followed by a boost to 5040 cGy. Post-operatively, pts received a median of 2 monthly cycles (range: 0-10 cycles) of LV (20 mg/m2) and 5-FU (425mg/m2). A toxicity assessment was performed at each visit using the NCI toxicity criteria modified for gastrointestinal toxicity. The median follow-up was 12 months (range: 3-48 months). All 32 patients were included in the analysis of toxicity, sphincter preservation, and downstaging. Analysis of patterns of failure and survival was limited to the 15 pts who had a minimum follow-up of 1yr or developed failure prior to 1 yr. For this subset the median follow-up was 24 months (range: 3-48 months). RESULTS: During the pre-op segment, individual grade 3+ acute toxicities were; diarrhea: 16%, bowel movements: 16%, leukopenia: 12%. The incidence of total toxicity was 25% ((8(32))). The median nadir counts were; WBC: 2.9 (range: 1.7-5.6), HGB: 12.4 (range: 7.1-15.0), and PLT (X1000): 161 (range: 113-237). The pathologic complete response rate was 9% ((3(32))). An additional 13% ((4(32))) had negative lymph nodes and 1-2 microscopic

  6. Methodological guidelines

    International Nuclear Information System (INIS)

    Halsnaes, K.; Callaway, J.M.; Meyer, H.J.

    1999-01-01

    The guideline document establishes a general overview of the main components of climate change mitigation assessment. This includes an outline of key economic concepts, scenario structure, common assumptions, modelling tools and country study assumptions. The guidelines are supported by Handbook Reports that contain more detailed specifications of calculation standards, input assumptions and available tools. The major objectives of the project have been provided a methodology, an implementing framework and a reporting system which countries can follow in meeting their future reporting obligations under the FCCC and for GEF enabling activities. The project builds upon the methodology development and application in the UNEP National Abatement Coasting Studies (UNEP, 1994a). The various elements provide countries with a road map for conducting climate change mitigation studies and submitting national reports as required by the FCCC. (au) 121 refs

  7. Methodological guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Halsnaes, K.; Callaway, J.M.; Meyer, H.J.

    1999-04-01

    The guideline document establishes a general overview of the main components of climate change mitigation assessment. This includes an outline of key economic concepts, scenario structure, common assumptions, modelling tools and country study assumptions. The guidelines are supported by Handbook Reports that contain more detailed specifications of calculation standards, input assumptions and available tools. The major objectives of the project have been provided a methodology, an implementing framework and a reporting system which countries can follow in meeting their future reporting obligations under the FCCC and for GEF enabling activities. The project builds upon the methodology development and application in the UNEP National Abatement Coasting Studies (UNEP, 1994a). The various elements provide countries with a road map for conducting climate change mitigation studies and submitting national reports as required by the FCCC. (au) 121 refs.

  8. AIDS guidelines.

    Science.gov (United States)

    Berger, R

    1986-04-30

    The Sun article, "Employers finding that AIDS in the workplace is a managerial nightmare" (April 3), did not accurately portray the status of AIDS in the workplace. The AIDS virus, HTLV III, is transmitted by body fluids, primarily semen and blood, and there is no known risk of transmitting the virus by casual contact in the workplace. The Center for Disease Control (CDC) released guidelines for child care workers last August. Guidelines on preventing transmission of AIDS in the workplace were issued by CDC in November 1985. These guidelines specifically discussed health care, personal service, and food service workers. The recommendations were against routine screening. Furthermore, employment should not be restricted on the basis of a positive HTLV III antibody test. A person with HTLV III infection should be exempt from the workplace only if there are circumstances interfering with job performance. In Maryland, the Governor's Task Force on AIDS has gone on record as endorsing CDC guidelines related to employment. Furthermore, the task force condemns discrimination based on the disease AIDS, AIDS Related Complex (ARC), or HTLV III infection. Increasingly AIDS patients are being considered legally disabled and therefore are protected by federal and state laws prohibiting discrimination on the basis of a handicap. Marylanders who are subjected to mandatory HTLV III screening in the workplace, or if discriminated against on the basis of HTLV III inefction, should contact the Maryland Commission on Human Relations, the Maryland Department of Health and Mental Hygiene, or the Health Education Resource Organization (HERO). All 3 of these resources guarantee confidentiality. It is only by employees reporting incidents that a nightmare in the workplace can be avoided in Maryland. full text

  9. GRADE guidelines

    DEFF Research Database (Denmark)

    Guyatt, Gordon H; Thorlund, Kristian; Oxman, Andrew D

    2013-01-01

    Presenting continuous outcomes in Summary of Findings tables presents particular challenges to interpretation. When each study uses the same outcome measure, and the units of that measure are intuitively interpretable (e.g., duration of hospitalization, duration of symptoms), presenting differences...... and absolute effects, presenting the ratio of the means of intervention and control groups, and presenting the results in minimally important difference units. We outline the merits and limitations of each alternative and provide guidance for meta-analysts and guideline developers....

  10. ASCOT guidelines

    International Nuclear Information System (INIS)

    1994-05-01

    These guidelines describe an approach used in conducting an Assessment of Safety Culture in Organizations Team (ASCOT) review. They are intended to assist the team members in conducting their reviews and at the same time provide guidance to hosts preparing to receive an ASCOT review. They may also be used by any organization wishing to conduct their own self-assessment of safety culture, independent of an ASCOT review

  11. 28 CFR 23.30 - Funding guidelines.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Funding guidelines. 23.30 Section 23.30 Judicial Administration DEPARTMENT OF JUSTICE CRIMINAL INTELLIGENCE SYSTEMS OPERATING POLICIES § 23.30 Funding guidelines. The following funding guidelines shall apply to all Crime Control Act funded...

  12. 32 CFR 231.11 - Guidelines.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 2 2010-07-01 2010-07-01 false Guidelines. 231.11 Section 231.11 National... PROCEDURES GOVERNING BANKS, CREDIT UNIONS AND OTHER FINANCIAL INSTITUTIONS ON DOD INSTALLATIONS Guidelines for Application of the Privacy Act to Financial Institution Operations § 231.11 Guidelines. (a) The...

  13. Human Factors Guidance for Control Room and Digital Human-System Interface Design and Modification, Guidelines for Planning, Specification, Design, Licensing, Implementation, Training, Operation and Maintenance

    Energy Technology Data Exchange (ETDEWEB)

    R. Fink, D. Hill, J. O' Hara

    2004-11-30

    Nuclear plant operators face a significant challenge designing and modifying control rooms. This report provides guidance on planning, designing, implementing and operating modernized control rooms and digital human-system interfaces.

  14. Human Factors Guidance for Control Room and Digital Human-System Interface Design and Modification. Guidelines for Planning, Specification, Design, Licensing, Implementation, Training, Operation and Maintenance

    International Nuclear Information System (INIS)

    Fink, R.; Hill, D.; O'Hara, J.

    2004-01-01

    Nuclear plant operators face a significant challenge designing and modifying control rooms. This report provides guidance on planning, designing, implementing and operating modernized control rooms and digital human-system interfaces

  15. RSK-guidelines for PWR reactors

    International Nuclear Information System (INIS)

    1979-01-01

    The RSK guidelines for PWA reactors of April 24, 1974, have been revised and amended in this edition. The RSK presents a summary of safety requirements to be observed in the design, construction, and operation of PWR reactors in the form of guidelines. From January 1979 onwards these guidelines will be the basis of siting and safety considerations for new PWR reactors, and newly built nuclear power plants will have to form these guidelines. They are not binding for existing nuclear power plants under construction or in operation. It will be a matter of individual discussion whether or not the guidelines will be applied in these plants. The main purpose of the guidelines is to facilitate discussion among RSK members and to give early information on necessary safety requirements. If the guidelines are observed by producers and operators, the RSK will make statements on individual projects at short notice. (orig./HP) [de

  16. A preliminary study on the optimal configuration and operating range of a “microgrid scale” air liquefaction plant for Liquid Air Energy Storage

    International Nuclear Information System (INIS)

    Borri, E.; Tafone, A.; Romagnoli, A.; Comodi, G.

    2017-01-01

    Highlights: • A liquefaction cycle for a microgrid scale Liquid Air Energy Storage is proposed. • Different liquefaction cycles are compared by means of parametric analysis. • The optimal configuration proposed is a Kapitza cycle with two stage compression. • The specific consumption of the optimal configuration is around 700 kW h/t. • Specific consumption reduces to 532 kW h/t if a pressurized phase separator is used. - Abstract: Liquid Air Energy Storage systems represent a sustainable solution to store energy. Although a lot of interest is dedicated to large scale systems (up to 300 tons per day), a small-scale Liquid Air Energy Storage can be used as energy storage as part of a microgrid and/or an energy distribution network. However, when scaling down the size of the system, the round trip efficiency decreases due to the low performance of the liquefaction process. In this paper a preliminary study on the optimal configuration for a microgrid scale liquefaction cycle (10 tons per 12 h) for a Liquid Air Energy Storage application is proposed in order to minimize the specific consumption. The Linde, Claude and Kapitza cycles are modelled and compared by means of a parametric analysis carried out with the software Aspen HYSYS. The results show that the two stages compression Kapitza cycle operating at 40 bar represents an optimal solution in terms of performance and cycle configuration resulting in a specific consumption of about 700 kW h/t. The analysis also shows that the implementation of a pressurized phase separator leads to a reduction of the specific consumption as high as 21% (≈550 kW h/t).

  17. A novel hybrid tobacco product that delivers a tobacco flavour note with vapour aerosol (Part 1): Product operation and preliminary aerosol chemistry assessment.

    Science.gov (United States)

    Poynton, Simon; Sutton, Joseph; Goodall, Sharon; Margham, Jennifer; Forster, Mark; Scott, Ken; Liu, Chuan; McAdam, Kevin; Murphy, James; Proctor, Christopher

    2017-08-01

    Vapour products have demonstrated potential to be a lower-risk alternative to cigarettes. The present study describes a novel hybrid tobacco product that combines a warm aerosol stream generated by an electronic vaporisation mechanism with tobacco top flavour from cut tobacco. During operation, the aerosol stream released from the vapour cartomiser is passed through a bed of blended cut tobacco by the puffing flow, elevating the tobacco temperature and eluting volatile tobacco flavour components. A preliminary but comprehensive analysis of the aerosol composition of the hybrid tobacco product found that emissions were dominated by the control vapour formulation. In non-targeted chemical screening, no detectable difference in GC scans was observed between the hybrid tobacco product and the control vapour product. However, a sensorially elevated tobacco flavour was confirmed by a consumer sensory panel (P products, only 26 were quantified. The novel action of tobacco heating and liquid aerosolisation produced classes and levels of toxicants that were similar to those of the control vapour product, but much lower than those of a Kentucky 3R4F reference cigarette. For nine toxicants mandated by the WHO Study Group on Tobacco Product Regulation for reduction in cigarette emissions, the levels were 91%-99% lower per puff in the hybrid tobacco product aerosol than in 3R4F smoke. Overall, the novel hybrid tobacco product provides a sensorially enhanced tobacco flavour, but maintains a toxicant profile similar to its parent vapour product with relatively low levels of known cigarette smoke toxicants. Copyright © 2017 British American Tobacco. Published by Elsevier Ltd.. All rights reserved.

  18. Dietary guidelines

    DEFF Research Database (Denmark)

    Jelsøe, Erling

    2015-01-01

    to food and eating and the emergence of proposals for integrated guidelines. It explores the conflicts and controversies that have arisen in the wake of the various proposals and identifies a number of different types of conflicts. These relate to conflicts of interests between the various actors involved...... and political resistance against initiatives that are perceived as being in conflict with the values of a market economy and free trade. Furthermore, there are controversies that can be broadly characterised as relating to the politics of knowledge and have to do with the differentiation of expertise...

  19. Revised version of quality guidelines for presurgical epilepsy evaluation and surgical epilepsy therapy issued by the Austrian, German, and Swiss working group on presurgical epilepsy diagnosis and operative epilepsy treatment.

    Science.gov (United States)

    Rosenow, Felix; Bast, Thomas; Czech, Thomas; Feucht, Martha; Hans, Volkmar H; Helmstaedter, Christoph; Huppertz, Hans-Jürgen; Noachtar, Soheyl; Oltmanns, Frank; Polster, Tilman; Seeck, Margitta; Trinka, Eugen; Wagner, Kathrin; Strzelczyk, Adam

    2016-08-01

    The definition of minimal standards remains pivotal as a basis for a high standard of care and as a basis for staff allocation or reimbursement. Only limited publications are available regarding the required staffing or methodologic expertise in epilepsy centers. The executive board of the working group (WG) on presurgical epilepsy diagnosis and operative epilepsy treatment published the first guidelines in 2000 for Austria, Germany, and Switzerland. In 2014, revised guidelines were published and the WG decided to publish an unaltered English translation in this report. Because epilepsy surgery is an elective procedure, quality standards are particularly high. As detailed in the first edition of these guidelines, quality control relates to seven different domains: (1) establishing centers with a sufficient number of sufficiently and specifically trained personnel, (2) minimum technical standards and equipment, (3) continuous medical education of employees, (4) surveillance by trained personnel during video electroencephalography (EEG) monitoring (VEM), (5) systematic acquisition of clinical and outcome data, (6) the minimum number of preoperative evaluations and epilepsy surgery procedures, and (7) the cooperation of epilepsy centers. These standards required the certification of the different professions involved and minimum numbers of procedures. In the subsequent decade, quite a number of colleagues were certified by the trinational WG; therefore, the executive board of the WG decided in 2013 to make these standards obligatory. This revised version is particularly relevant given that the German procedure classification explicitly refers to the guidelines of the WG with regard to noninvasive/invasive preoperative video-EEG monitoring and invasive intraoperative diagnostics in epilepsy. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.

  20. Roadside infrastructure for safer European roads: D08 European best practice for roadside design: guidelines for maintenance and operations of roadside infrastructure. Project RISER, European Community

    NARCIS (Netherlands)

    Andersson, J.; Lanner, G.; Wink, W.; Halleman, B.; Naing, C.L.; Thomson, R.; Fagerlind, H.; Dupre, G.; Bisson, O.; Carcia, J.M.; Lopez, F.; Papi, J.; Martinez, A.V.; Amengual, A.; Valtonen, J.; Kelkka, M.; Goose, U.; Klootwijk, C.W.; Hoogvelt, B.; Horst, A.R.A. van der; Ridder, S. de; Hoschopf, H.; Hill, J.

    2006-01-01

    Maintenance and operations of road safety equipment and infrastructure ensure that all safety related elements of the road system are operating as they were designed, tested, and approved. Maintenance of road equipment should not only be considered as the repair of broken or damaged equipment, but

  1. Preliminary hazards analysis -- vitrification process

    International Nuclear Information System (INIS)

    Coordes, D.; Ruggieri, M.; Russell, J.; TenBrook, W.; Yimbo, P.

    1994-06-01

    This paper presents a Preliminary Hazards Analysis (PHA) for mixed waste vitrification by joule heating. The purpose of performing a PHA is to establish an initial hazard categorization for a DOE nuclear facility and to identify those processes and structures which may have an impact on or be important to safety. The PHA is typically performed during and provides input to project conceptual design. The PHA is then followed by a Preliminary Safety Analysis Report (PSAR) performed during Title 1 and 2 design. The PSAR then leads to performance of the Final Safety Analysis Report performed during the facility's construction and testing. It should be completed before routine operation of the facility commences. This PHA addresses the first four chapters of the safety analysis process, in accordance with the requirements of DOE Safety Guidelines in SG 830.110. The hazards associated with vitrification processes are evaluated using standard safety analysis methods which include: identification of credible potential hazardous energy sources; identification of preventative features of the facility or system; identification of mitigative features; and analyses of credible hazards. Maximal facility inventories of radioactive and hazardous materials are postulated to evaluate worst case accident consequences. These inventories were based on DOE-STD-1027-92 guidance and the surrogate waste streams defined by Mayberry, et al. Radiological assessments indicate that a facility, depending on the radioactive material inventory, may be an exempt, Category 3, or Category 2 facility. The calculated impacts would result in no significant impact to offsite personnel or the environment. Hazardous materials assessment indicates that a Mixed Waste Vitrification facility will be a Low Hazard facility having minimal impacts to offsite personnel and the environment

  2. Preliminary hazards analysis -- vitrification process

    Energy Technology Data Exchange (ETDEWEB)

    Coordes, D.; Ruggieri, M.; Russell, J.; TenBrook, W.; Yimbo, P. [Science Applications International Corp., Pleasanton, CA (United States)

    1994-06-01

    This paper presents a Preliminary Hazards Analysis (PHA) for mixed waste vitrification by joule heating. The purpose of performing a PHA is to establish an initial hazard categorization for a DOE nuclear facility and to identify those processes and structures which may have an impact on or be important to safety. The PHA is typically performed during and provides input to project conceptual design. The PHA is then followed by a Preliminary Safety Analysis Report (PSAR) performed during Title 1 and 2 design. The PSAR then leads to performance of the Final Safety Analysis Report performed during the facility`s construction and testing. It should be completed before routine operation of the facility commences. This PHA addresses the first four chapters of the safety analysis process, in accordance with the requirements of DOE Safety Guidelines in SG 830.110. The hazards associated with vitrification processes are evaluated using standard safety analysis methods which include: identification of credible potential hazardous energy sources; identification of preventative features of the facility or system; identification of mitigative features; and analyses of credible hazards. Maximal facility inventories of radioactive and hazardous materials are postulated to evaluate worst case accident consequences. These inventories were based on DOE-STD-1027-92 guidance and the surrogate waste streams defined by Mayberry, et al. Radiological assessments indicate that a facility, depending on the radioactive material inventory, may be an exempt, Category 3, or Category 2 facility. The calculated impacts would result in no significant impact to offsite personnel or the environment. Hazardous materials assessment indicates that a Mixed Waste Vitrification facility will be a Low Hazard facility having minimal impacts to offsite personnel and the environment.

  3. 40 CFR Appendix B to Subpart E of... - Federal Guidelines-User Charges for Operation and Maintenance of Publicly Owned Treatment Works

    Science.gov (United States)

    2010-07-01

    ... charges is to distribute the cost of operation and maintenance of publicly owned treatment works to the... not be acceptable. Savings resulting from economies of scale should be apportioned to all users or...

  4. Cell emulation and preliminary results.

    Science.gov (United States)

    2016-07-01

    This report details preliminary results of the testing plan implemented by the Hawaii Natural Energy Institute to evaluate Electric Vehicle (EV) battery durability and reliability under electric utility grid operations. Commercial EV battery cells ar...

  5. Guidelines for the application of upper-room ultraviolet germicidal irradiation for preventing transmission of airborne contagion -- Part 2: Design and operation guidance

    Energy Technology Data Exchange (ETDEWEB)

    First, M.W.; Nardell, E.A.; Chaisson, W.; Riley, R.

    1999-07-01

    Installations of ultraviolet germicidal irradiation (UVGI) have been stimulated recently by a sudden rise in the incidence of tuberculosis. Hospitals, jails, and homeless shelters have been the most frequently equipped facilities because they are places where many tuberculosis cases are found, the buildings housing them tend to be old and not suited for economical increases in air exchange rates, and the work staffs have been apprehensive about transmission to themselves and their families. The diversity in structures currently being equipped with UVGI installations, plus the introduction of new designs of lamps and fixtures, have made it clear that an updated review of equipment performance factors and practical installation guidelines will be useful to interested parties. Illustrative examples are given of installations that have been made in a diverse set of facilities. In addition, representative figures are given to compare the cost of HVAC installations and UVGI installations that give an equivalent number of air changes based on equal levels of reduction in airborne microorganisms.

  6. 75 FR 29358 - Maritime Security Directive 104-6 (Rev 2 and 3); Guidelines for U.S. Vessels Operating in High...

    Science.gov (United States)

    2010-05-25

    ... designated high risk waters, and provides additional anti-piracy guidance and mandatory measures for these vessels operating in these areas where acts of piracy and armed robbery against ships are prevalent... piratical activities. The combination of piracy and weak rule of law in the region offers a potential...

  7. Author Guidelines

    Directory of Open Access Journals (Sweden)

    Yunisrina Qismullah Yusuf

    2016-03-01

    Full Text Available Guidelines for Article Submission SiELE journal accepts articles on research and development in the field of teaching and learning of English, linguistics, educational development, policy and cultural studies in education. To be considered for publication, the article should be presented in the following system: First page: include a title page with the full title of the paper (must not exceed 16 words, the author(s’ name(s, affiliation(s, phone number(s and e-mail address of the corresponding author. A brief bio-data of the author(s (maximum of 100 words is provided in this page. Second p age and subsequent page: Submissions should be between 4000-6000 (including abstract, table(s, figure(s and references in A4 size paper with margins as the following: top 3 cm, bottom 3 cm, right 2.5 cm and left 4 cm. The font is Times New Roman, size 12 and single spaced. The article should generally consist of the following sections: introduction, review of literature, method, findings, discussion and conclusion. Headings and subheadings should be presented as follows (provide a space between the headings and sub-headings. 1 INTRODUCTION 1.1 Subheading of the Content 1.1.1 Subheading of the Content For Tables, the title size is 12 and the content size is 10. Please number the tables subsequently throughout your article and the title is written above the table. For Figures, the title size is 12 and the content size (if any is 10. Please number the figures subsequently throughout your article and the title is written below the figure. The reference list should be arranged alphabetically following the guidelines of the Publication Manual of the American Psychological Association (5th ed.. See the following examples:   Book: Ellis, R. (2003. Task-based language learning and teaching. Oxford: Oxford University Press. Internet source: Andrewes, S. (2003. Group work v. whole-class activities. Retrieved October 1, 2012 from http://www.teachingenglish.org

  8. Author Guidelines

    Directory of Open Access Journals (Sweden)

    Yunisrina Qismullah Yusuf

    2015-03-01

    Full Text Available Guidelines for Article Submission SiELE journal accepts articles on research and development in the field of teaching and learning of English, linguistics, educational development, policy and cultural studies in education. To be considered for publication, the article should be presented in the following system: First page: include a title page with the full title of the paper (must not exceed 16 words, the author(s’ name(s, affiliation(s, phone number(s and e-mail address of the corresponding author. A brief bio-data of the author(s (maximum of 100 words is provided in this page. Second page and subsequent page: Submissions should be between 4000-6000 (including abstract, table(s, figure(s and references in A4 size paper with margins as the following: top 3 cm, bottom 3 cm, right 2.5 cm and left 4 cm. The font is Times New Roman, size 12 and single spaced. The article should generally consist of the following sections: introduction, review of literature, method, findings, discussion and conclusion. Headings and subheadings should be presented as follows (provide a space between the headings and sub-headings. 1 INTRODUCTION 1.1 Subheading of the content 1.1.1 Subheading of the content For Tables, the title size is 12 and the content size is 10. Please number the tables subsequently throughout your article and the title is written above the table. For Figures, the title size is 12 and the content size (if any is 10. Please number the figures subsequently throughout your article and the title is written below the figure. The reference list should be arranged alphabetically following the guidelines of the Publication Manual of the American Psychological Association (5th ed.. See the following examples: Back Matter| 79 80 | STUDIES IN ENGLISH LANGUAGE AND EDUCATION, Volume 1, Number 1, March 2014 Book: Ellis, R. (2003. Task-based language learning and teaching. Oxford: Oxford University Press. Internet source: Andrewes, S. (2003. Group work v

  9. Author Guidelines

    Directory of Open Access Journals (Sweden)

    Yunisrina Qismullah Yusuf

    2015-10-01

    Full Text Available Guidelines for Article Submission   SiELE journal accepts articles on research and development in the field of teaching and learning of English, linguistics, educational development, policy and cultural studies in education. To be considered for publication, the article should be presented in the following system: First page: include a title page with the full title of the paper (must not exceed 16 words, the author(s’ name(s, affiliation(s, phone number(s and e-mail address of the corresponding author. A brief bio-data of the author(s (maximum of 100 words is provided in this page. Second page and subsequent page: Submissions should be between 4000-6000 (including abstract, table(s, figure(s and references in A4 size paper with margins as the following: top 3 cm, bottom 3 cm, right 2.5 cm and left 4 cm. The font is Times New Roman, size 12 and single spaced. The article should generally consist of the following sections: introduction, review of literature, method, findings, discussion and conclusion. Headings and subheadings should be presented as follows (provide a space between the headings and sub-headings. 1         INTRODUCTION 1.1      Subheading of the Content  1.1.1   Subheading of the Content  For Tables, the title size is 12 and the content size is 10. Please number the tables subsequently throughout your article and the title is written above the table. For Figures, the title size is 12 and the content size (if any is 10. Please number the figures subsequently throughout your article and the title is written below the figure. The reference list should be arranged alphabetically following the guidelines of the Publication Manual of the American Psychological Association (5th ed.. See the following examples:   Book: Ellis, R. (2003. Task-based language learning and teaching. Oxford: Oxford University Press. Internet source: Andrewes, S. (2003. Group work v. whole-class activities. Retrieved October 1, 2012 from

  10. Author Guidelines

    Directory of Open Access Journals (Sweden)

    Yunisrina Qismullah Yusuf

    2014-03-01

    Full Text Available Guidelines for Article Submission   SiELE journal accepts articles on research and development in the field of teaching and learning of English, linguistics, educational development, policy and cultural studies in education. To be considered for publication, the article should be presented in the following system: First page: include a title page with the full title of the paper (must not exceed 16 words, the author(s’ name(s, affiliation(s, phone number(s and e-mail address of the corresponding author. A brief bio-data of the author(s (maximum of 100 words is provided in this page. Second page and subsequent page: Submissions should be between 4000-6000 (including abstract, table(s, figure(s and references in A4 size paper with margins as the following: top 3 cm, bottom 3 cm, right 2.5 cm and left 4 cm. The font is Times New Roman, size 12 and single spaced. The article should generally consist of the following sections: introduction, review of literature, method, findings, discussion and conclusion. Headings and subheadings should be presented as follows (provide a space between the headings and sub-headings. 1         INTRODUCTION 1.1      Subheading of the content  1.1.1   Subheading of the content  For Tables, the title size is 12 and the content size is 10. Please number the tables subsequently throughout your article and the title is written above the table. For Figures, the title size is 12 and the content size (if any is 10. Please number the figures subsequently throughout your article and the title is written below the figure. The reference list should be arranged alphabetically following the guidelines of the Publication Manual of the American Psychological Association (5th ed.. See the following examples:   Book: Ellis, R. (2003. Task-based language learning and teaching. Oxford: Oxford University Press. Internet source: Andrewes, S. (2003. Group work v. whole-class activities. Retrieved October 1, 2012 from

  11. Author Guidelines

    Directory of Open Access Journals (Sweden)

    Yunisrina Qismullah Yusuf

    2014-09-01

    Full Text Available Guidelines for Article Submission   SiELE journal accepts articles on research and development in the field of teaching and learning of English, linguistics, educational development, policy and cultural studies in education. To be considered for publication, the article should be presented in the following system: First page: include a title page with the full title of the paper (must not exceed 16 words, the author(s’ name(s, affiliation(s, phone number(s and e-mail address of the corresponding author. A brief bio-data of the author(s (maximum of 100 words is provided in this page. Second page and subsequent page: Submissions should be between 4000-6000 (including abstract, table(s, figure(s and references in A4 size paper with margins as the following: top 3 cm, bottom 3 cm, right 2.5 cm and left 4 cm. The font is Times New Roman, size 12 and single spaced. The article should generally consist of the following sections: introduction, review of literature, method, findings, discussion and conclusion. Headings and subheadings should be presented as follows (provide a space between the headings and sub-headings. 1         INTRODUCTION 1.1      Subheading of the content  1.1.1   Subheading of the content  For Tables, the title size is 12 and the content size is 10. Please number the tables subsequently throughout your article and the title is written above the table. For Figures, the title size is 12 and the content size (if any is 10. Please number the figures subsequently throughout your article and the title is written below the figure. The reference list should be arranged alphabetically following the guidelines of the Publication Manual of the American Psychological Association (5th ed.. See the following examples:   Book: Ellis, R. (2003. Task-based language learning and teaching. Oxford: Oxford University Press. Internet source: Andrewes, S. (2003. Group work v. whole-class activities. Retrieved October 1, 2012 from

  12. ITER operating limit definition criteria

    International Nuclear Information System (INIS)

    Ciattaglia, S.; Barabaschi, P.; Carretero, J.A.; Chiocchio, S.; Hureau, D.; Girard, J.Ph.; Gordon, C.; Portone, A.; Rodrigo, L. Rodriguez; Roldan, C.; Saibene, G.; Uzan-Elbez, J.

    2009-01-01

    The operating limits and conditions (OLCs) are operating parameters and conditions, chosen among all system/components, which, together, define the domain of the safe operation of ITER in all foreseen ITER states (operation, maintenance, commissioning). At the same time they are selected to guarantee the required operation flexibility which is a critical factor for the success of an experimental machine such as ITER. System and components that are important for personnel or public safety (safety important class, SIC) are identified considering their functional importance in the overall plant safety analysis. SIC classification has to be presented already in the preliminary safety analysis report and approved by the licensing authority before manufacturing and construction. OLCs comprise the safety limits that, if exceeded, could result in a potential safety hazard, the relevant settings that determine the intervention of SIC systems, and the operational limits on equipment which warn against or stop a functional deviation from a planned operational status that could challenge equipment and functions. Some operational conditions, e.g. in-Vacuum Vessel (VV) radioactive inventories, will be controlled through procedures. Operating experience from present tokamaks, in particular JET, and from nuclear plants, is considered to the maximum possible extent. This paper presents the guidelines for the development of the ITER OLCs with particular reference to safety limits.

  13. Guidelines for Description

    NARCIS (Netherlands)

    Links, P.; Horsman, Peter; Kühnel, Karsten; Priddy, M.; Reijnhoudt, Linda; Merenmies, Mark

    2013-01-01

    The Guidelines follow the conceptual metadata model (deliverable 17.2). They include guidelines for description of collection-holding institutions, document collections, organisations, personalities, events, camps and ghettos. As much as possible the guidelines comply with the descriptive standards

  14. Author Guidelines

    Directory of Open Access Journals (Sweden)

    Chief Editor

    2015-12-01

    Full Text Available Author GuidelinesIJCH strictly adheres on the recommendations for the Conduct, Reporting, Editing and Publication of Scholarly Work in Medical Journals as per the standard universal guidelines given by International Committee of Medical Journal Editors (ICMJE - Recommendations for Uniform Requirements for Manuscripts. Authors are requested to visit http://www.icmje.org/index.html before making online submission of their manuscript(s.  http://www.icmje.org/recommendations/browse/manuscript-preparation/preparing-for-submission.html Preparing for SubmissionPAGE CONTENTSGeneral PrinciplesReporting GuidelinesManuscript SectionsTitle PageAbstractIntroductionMethodsResultsDiscussionReferencesTablesIllustrations (FiguresUnits of MeasurementAbbreviations and Symbols1. General PrinciplesThe text of articles reporting original research is usually divided into Introduction, Methods, Results, and Discussion sections. This so-called “IMRAD” structure is not an arbitrary publication format but a reflection of the process of scientific discovery. Articles often need subheadings within these sections to further organize their content. Other types of articles, such as meta-analyses, may require different formats, while case reports, narrative reviews, and editorials may have less structured or unstructured formats.Electronic formats have created opportunities for adding details or sections, layering information, cross-linking, or extracting portions of articles in electronic versions. Supplementary electronic-only material should be submitted and sent for peer review simultaneously with the primary manuscript.2. Reporting GuidelinesReporting guidelines have been developed for different study designs; examples include CONSORT for randomized trials, STROBE for observational studies, PRISMA for systematic reviews and meta-analyses, and STARD for studies of diagnostic accuracy. Journals are encouraged to ask authors to follow these guidelines because

  15. Author Guidelines

    Directory of Open Access Journals (Sweden)

    Chief Editor

    2016-06-01

    Full Text Available AUTHOR GUIDELINES Indian Journal of Community Health (IJCH accepts only online submission of manuscript(s by using Open Journal software (OJS at http://www.iapsmupuk.org/journal/index.php/IJCH/login Online SubmissionsAlready have a Username/Password for Indian Journal of Community Health (IJCH? GO TO LOGINNeed a Username/Password?GO TO REGISTRATIONNote: Registration and login are required to submit items online and to track the status of current submissions.Author GuidelinesIJCH strictly adheres on the recommendations for the Conduct, Reporting, Editing and Publication of Scholarly Work in Medical Journals as per the standard universal guidelines given by International Committee of Medical Journal Editors (ICMJE - Recommendations for Uniform Requirements for Manuscripts. Authors are requested to visit http://www.icmje.org/index.html before making online submission of their manuscript(s. http://www.icmje.org/recommendations/browse/manuscript-preparation/preparing-for-submission.html Preparing for SubmissionGeneral PrinciplesReporting GuidelinesManuscript SectionsTitle PageAbstractIntroductionMethodsResultsDiscussionReferencesTablesIllustrations (FiguresUnits of MeasurementAbbreviations and Symbols 1. General PrinciplesThe text of articles reporting original research is usually divided into Introduction, Methods, Results, and Discussion sections. This so-called “IMRAD” structure is not an arbitrary publication format but a reflection of the process of scientific discovery. Articles often need subheadings within these sections to further organize their content. Other types of articles, such as meta-analyses, may require different formats, while case reports, narrative reviews, and editorials may have less structured or unstructured formats.Electronic formats have created opportunities for adding details or sections, layering information, cross-linking, or extracting portions of articles in electronic versions. Supplementary electronic

  16. AUTHOR GUIDELINES

    Directory of Open Access Journals (Sweden)

    Chief Editor

    2014-12-01

    Full Text Available AUTHOR GUIDELINESIndian Journal of Community Health (IJCH accepts only online submission of manuscript(s by using Open Journal software (OJS at http://www.iapsmupuk.org/journal/index.php/IJCH/loginOnline SubmissionsAlready have a Username/Password for Indian Journal of Community Health (IJCH? GO TO LOGINNeed a Username/Password?GO TO REGISTRATIONNote: Registration and login are required to submit items online and to track the status of current submissions.Author GuidelinesIJCH strictly adheres on the recommendations for the Conduct, Reporting, Editing and Publication of Scholarly Work in Medical Journals as per the standard universal guidelines given by International Committee of Medical Journal Editors (ICMJE - Recommendations for Uniform Requirements for Manuscripts. Authors are requested to visit http://www.icmje.org/index.html before making online submission of their manuscript(s.SectionsEditorial:On issues of current public health needAbout 1000 – 1200 wordsReferences: 5 – 10 (PubMed - Citation preferredInvited Commentary:Brief, provocative, opinionated communicationsOn issues of current public health needMain Text: 750-1000 words excluding referencesReferences: 5 – 10 (PubMed - Citation preferredOriginal Article:Articles from Original ResearchStructured abstract: 250 wordsMain Text: 2500 - 3000 words, IMRD formatKey Words: 5 - 8References: 20 – 25 (PubMed - Citation preferredTables / Figures: 3 – 4*Certificate of clearance from respective Institutional Ethical Committee (IECReview Article:On subject of public health relevanceAbstract: 250 wordsMain Text: 2500 - 3000 wordsKey Words: 3 - 4References: 20 – 25 (PubMed - Citation preferredTables / Figures: 3 – 4Short Communication / Article:Short report of a research project / outbreakMain Text : 1000 – 1200 wordsReferences: 10 – 15 (PubMed - Citation preferredTable / Figure: 01*Certificate of clearance from respective Institutional Ethical Committee (IECReport from the field

  17. On the improvement of the response capability of the control room operator in a pressurized water reactor nuclear power plant in a severe earthquake through the use of emergency response guidelines

    International Nuclear Information System (INIS)

    Lee, S.

    1989-01-01

    Recent probabilistic risk assessment studies indicate that potential accidents initiated by large earthquakes are among the major contributors to public risk from nuclear power plants. During a severe earthquake, the symptoms presented to operators may be unreliable and may endanger the validity of actions in emergency response guidelines (ERGs). The objective of the present study is to improve the operator capability of responding to seismic damage through the use of ERGS. The methods used are to deterministically identify the possible weakness of ERGs, given a severe earthquake, and to probabilistically evaluate those identified weaknesses. Several cases are postulated. Each of them contains system failures with or without indicator failures and leads the core to meltdown conditions if the operator follows the ERGs strictly without any deviation. The likelihood of each case is estimated. A LISP program is developed to estimate the plant seismic risk with which the relative risk contribution of each postulated case is estimated. As a result, ten cases are postulated and possible remedies for each case are discussed. The likelihood of each case is estimated to be not negligible. The identified indicator failures should be considered in future refinement of the ERGS. The development of an expert system to provide remedial procedures should be considered after a more thorough study in which many more cases are postulated

  18. Guidelines for District Heating Substations

    Energy Technology Data Exchange (ETDEWEB)

    2009-07-15

    The present guidelines contain a set of recommendations focusing on planning, installation, use and maintenance of district heating (DH) substations within district heating systems throughout Europe. The recommendations were developed in order to enable readers to develop well-functioning substations and an effective heat and domestic warm water delivery. These guidelines are intended to give the most effective overall solutions for various parts of the customer installation. The guidelines are not meant to specify the different components of the substation such as meters or heat exchangers. The guidelines deal with a wide variety of issues concerning both present systems of today and district heating systems of the future. Specific handling and maintenance recommendations are mainly focused on present modern systems but are also intended to cover the future situation as much as is feasible. For this reason, certain existing systems are not dealt with in these guidelines. For instance, these guidelines do not cover steam systems, systems with temperatures exceeding 110 deg C and pressure levels above 1.6 MPa. The guidelines include a chapter on the heat meter, as the meter and especially the meter installation is always installed simultaneously with the rest of the substation. These guidelines aim to provide best-practice and easy-to-handle recommendations for: - those who are responsible for relations between district heating utilities and customers; - those who own or maintain a building connected to the district heating network; - those who manufacture, plan, purchase, test and install substations. These guidelines do not deal with investment or cost aspects, but in general, Euroheat and Power recommends looking at the lifetime cost of all components of the substation, instead of investment costs alone. An example of this is provided in Chapter 7.8. The Guidelines were developed based on the most optimal operating principles of substations and meters

  19. Efforts to update firefighter safety zone guidelines

    Science.gov (United States)

    Bret Butler

    2009-01-01

    One of the most critical decisions made on wildland fires is the identification of suitable safety zones for firefighters during daily fire management operations. To be effective (timely, repeatable, and accurate), these decisions rely on good training and judgment, but also on clear, concise guidelines. This article is a summary of safety zone guidelines and the...

  20. Guidelines for preparing IAEA design information questionnaires

    International Nuclear Information System (INIS)

    Swartz, J.M.; Bieber, A.M.

    1980-01-01

    The format of the IAEA Design Information Questionnaires and the SAI prepared guidelines for completing them, is described. The guidelines should assist facility operators in meeting the time constraints set forth in the Subsidiary Arrangements by effectively supplying the information needed by the IAEA and in minimizing resource allocations to the preparation effort. 8 refs

  1. Optical techniques for the determination of nitrate in environmental waters: Guidelines for instrument selection, operation, deployment, maintenance, quality assurance, and data reporting

    Science.gov (United States)

    Pellerin, Brian A.; Bergamaschi, Brian A.; Downing, Bryan D.; Saraceno, John Franco; Garrett, Jessica D.; Olsen, Lisa D.

    2013-01-01

    The recent commercial availability of in situ optical sensors, together with new techniques for data collection and analysis, provides the opportunity to monitor a wide range of water-quality constituents on time scales in which environmental conditions actually change. Of particular interest is the application of ultraviolet (UV) photometers for in situ determination of nitrate concentrations in rivers and streams. The variety of UV nitrate sensors currently available differ in several important ways related to instrument design that affect the accuracy of their nitrate concentration measurements in different types of natural waters. This report provides information about selection and use of UV nitrate sensors by the U.S. Geological Survey to facilitate the collection of high-quality data across studies, sites, and instrument types. For those in need of technical background and information about sensor selection, this report addresses the operating principles, key features and sensor design, sensor characterization techniques and typical interferences, and approaches for sensor deployment. For those needing information about maintaining sensor performance in the field, key sections in this report address maintenance and calibration protocols, quality-assurance techniques, and data formats and reporting. Although the focus of this report is UV nitrate sensors, many of the principles can be applied to other in situ optical sensors for water-quality studies.

  2. Operative fixation of rib fractures after blunt trauma: A practice management guideline from the Eastern Association for the Surgery of Trauma.

    Science.gov (United States)

    Kasotakis, George; Hasenboehler, Erik A; Streib, Erik W; Patel, Nimitt; Patel, Mayur B; Alarcon, Louis; Bosarge, Patrick L; Love, Joseph; Haut, Elliott R; Como, John J

    2017-03-01

    Rib fractures are identified in 10% of all injury victims and are associated with significant morbidity (33%) and mortality (12%). Significant progress has been made in the management of rib fractures over the past few decades, including operative reduction and internal fixation (rib ORIF); however, the subset of patients that would benefit most from this procedure remains ill-defined. The aim of this project was to develop evidence-based recommendations. Population, intervention, comparison, and outcome (PICO) questions were formulated for patients with and without flail chest. Outcomes of interest included mortality, duration of mechanical ventilation (DMV), hospital and intensive care unit (ICU) length of stay (LOS), incidence of pneumonia, need for tracheostomy, and pain control. A systematic review and meta-analysis of currently available evidence was performed per the Grading of Recommendations Assessment, Development, and Evaluation methodology. Twenty-two studies were identified and analyzed. These included 986 patients with flail chest, of whom 334 underwent rib ORIF. Rib ORIF afforded lower mortality; shorter DMV, hospital LOS, and ICU LOS; and lower incidence of pneumonia and need for tracheostomy. The data quality was deemed very low, with only three prospective randomized trials available. Analyses for pain in patients with flail chest and all outcomes in patients with nonflail chest were not feasible due to inadequate data. In adult patients with flail chest, we conditionally recommend rib ORIF to decrease mortality; shorten DMV, hospital LOS, and ICU LOS; and decrease incidence of pneumonia and need for tracheostomy. We cannot offer a recommendation for pain control, or any of the outcomes in patients with nonflail chest with currently available data. Systematic review/meta-analysis, level III.

  3. Los Alamos National Laboratory corregated metal pipe saw facility preliminary safety analysis report. Volume I

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1990-09-19

    This Preliminary Safety Analysis Report addresses site assessment, facility design and construction, and design operation of the processing systems in the Corrugated Metal Pipe Saw Facility with respect to normal and abnormal conditions. Potential hazards are identified, credible accidents relative to the operation of the facility and the process systems are analyzed, and the consequences of postulated accidents are presented. The risk associated with normal operations, abnormal operations, and natural phenomena are analyzed. The accident analysis presented shows that the impact of the facility will be acceptable for all foreseeable normal and abnormal conditions of operation. Specifically, under normal conditions the facility will have impacts within the limits posted by applicable DOE guidelines, and in accident conditions the facility will similarly meet or exceed the requirements of all applicable standards. 16 figs., 6 tabs.

  4. Introducing guidelines into clinical practice.

    Science.gov (United States)

    Fowkes, F G; Roberts, C J

    1984-04-01

    The impetus for guidelines of practice has been accelerated by a worldwide trend towards insurance based systems of health care. In the past it has been the tradition for the clinician to order all the diagnostic procedures that conceivably might help to clarify what is wrong with a patient, or what course of treatment should be followed. This traditional view ignores the stubborn economic reality that resources are finite and that it is no longer possible to be both endlessly generous and continually fair. Making judgements about the need for, and value of, services now forms an important part of coping with this problem. Clinical practice has to strive to be as safe as possible and to produce a given benefit at a socially acceptable cost. Guidelines are recommendations, preferably developed by clinicians themselves, which describe how and when individual clinical activities should be offered in order to achieve these objectives. Utilisation review of current practice is a valuable source of information for the development of guidelines. In the United Kingdom the Royal College of Radiologists attempted to do this in connection with the use of pre-operative chest X-rays. In 1979 they published the findings of a multicentre review of 10,619 consecutive cases of elective non-cardiopulmonary surgery undertaken in 8 centres throughout the United Kingdom. Substantial variations were found in national practice. Use of pre-operative chest X-rays varied from 11.5% of patients in one centre to 54.2% of patients in another centre. The study also found that the chest X-ray report did not seem to have much influence on the decision to operate nor on the decision to use inhalation anaesthesia. The College study failed to find "any evidence at all for the effectiveness of pre-operative chest X-ray when used routinely" and it was estimated that even if the procedure was 10% effective the costs of avoiding one death would be approximately 1 million pounds. These findings provided

  5. Cost analysis guidelines

    International Nuclear Information System (INIS)

    Strait, R.S.

    1996-01-01

    The first phase of the Depleted Uranium Hexafluoride Management Program (Program)--management strategy selection--consists of several program elements: Technology Assessment, Engineering Analysis, Cost Analysis, and preparation of an Environmental Impact Statement (EIS). Cost Analysis will estimate the life-cycle costs associated with each of the long-term management strategy alternatives for depleted uranium hexafluoride (UF6). The scope of Cost Analysis will include all major expenditures, from the planning and design stages through decontamination and decommissioning. The costs will be estimated at a scoping or preconceptual design level and are intended to assist decision makers in comparing alternatives for further consideration. They will not be absolute costs or bid-document costs. The purpose of the Cost Analysis Guidelines is to establish a consistent approach to analyzing of cost alternatives for managing Department of Energy's (DOE's) stocks of depleted uranium hexafluoride (DUF6). The component modules that make up the DUF6 management program differ substantially in operational maintenance, process-options, requirements for R and D, equipment, facilities, regulatory compliance, (O and M), and operations risk. To facilitate a consistent and equitable comparison of costs, the guidelines offer common definitions, assumptions or basis, and limitations integrated with a standard approach to the analysis. Further, the goal is to evaluate total net life-cycle costs and display them in a way that gives DOE the capability to evaluate a variety of overall DUF6 management strategies, including commercial potential. The cost estimates reflect the preconceptual level of the designs. They will be appropriate for distinguishing among management strategies

  6. A web-based remote radiation treatment planning system using the remote desktop function of a computer operating system: a preliminary report.

    Science.gov (United States)

    Suzuki, Keishiro; Hirasawa, Yukinori; Yaegashi, Yuji; Miyamoto, Hideki; Shirato, Hiroki

    2009-01-01

    We developed a web-based, remote radiation treatment planning system which allowed staff at an affiliated hospital to obtain support from a fully staffed central institution. Network security was based on a firewall and a virtual private network (VPN). Client computers were installed at a cancer centre, at a university hospital and at a staff home. We remotely operated the treatment planning computer using the Remote Desktop function built in to the Windows operating system. Except for the initial setup of the VPN router, no special knowledge was needed to operate the remote radiation treatment planning system. There was a time lag that seemed to depend on the volume of data traffic on the Internet, but it did not affect smooth operation. The initial cost and running cost of the system were reasonable.

  7. Preliminary Results of the Determination of Inlet-Pressure Distortion Effects on Compressor Stall and Altitude Operating Limits of the J57-P-1 Turbojet Engine

    Science.gov (United States)

    Wallner, L. E.; Lubick, R. J.; Chelko, L. J.

    1955-01-01

    During an investigation of the J57-P-1 turbojet engine in the Lewis altitude wind tunnel, effects of inlet-flow distortion on engine stall characteristics and operating limits were determined. In addition to a uniform inlet-flow profile, the inlet-pressure distortions imposed included two radial, two circumferential, and one combined radial-circumferential profile. Data were obtained over a range of compressor speeds at an altitude of 50,000 and a flight Mach number of 0.8; in addition, the high- and low-speed engine operating limits were investigated up to the maximum operable altitude. The effect of changing the compressor bleed position on the stall and operating limits was determined for one of the inlet distortions. The circumferential distortions lowered the compressor stall pressure ratios; this resulted in less fuel-flow margin between steady-state operation and compressor stall. Consequently, the altitude operating Limits with circumferential distortions were reduced compared with the uniform inlet profile. Radial inlet-pressure distortions increased the pressure ratio required for compressor stall over that obtained with uniform inlet flow; this resulted in higher altitude operating limits. Likewise, the stall-limit fuel flows required with the radial inlet-pressure distortions were considerably higher than those obtained with the uniform inlet-pressure profile. A combined radial-circumferential inlet distortion had effects on the engine similar to the circumferential distortion. Bleeding air between the two compressors eliminated the low-speed stall limit and thus permitted higher altitude operation than was possible without compressor bleed.

  8. Air quality model guideline

    International Nuclear Information System (INIS)

    Idriss, A.; Spurrell, F.

    2009-06-01

    Alberta Environment has developed a guidelines for operations and proposed operations that require approvals under the province's Environmental Protection and Enhancement Act or that operate under a code of practice for emissions to the atmosphere. In an effort to ensure consistency in the use of dispersion models for regulatory applications in Alberta, this document provided detailed guidance on suitable methods and approaches that should be employed to assess air quality from emission sources, specifically, information required to demonstrate that a source meets the Alberta ambient air quality objectives. The document outlined the statutory authority and provided an overview of the approach. It provided detailed advice on the types and uses of dispersion models with particular reference to the modelling protocol, input data, and output interpretation. Guidance on the application of regulatory models were also presented. Various models were described and their intended uses were explained. Internet addresses for different modelling resources were also offered. Last, some information about regional modelling in the province of Alberta was discussed. 40 refs., 4 tabs., 7 figs., 3 appendices.

  9. Emergency Response Guideline Development

    International Nuclear Information System (INIS)

    Gary D Storrick

    2007-01-01

    Task 5 of the collaborative effort between ORNL, Brazil, and Westinghouse for the International Nuclear Energy Research Initiative entitled 'Development of Advanced Instrumentation and Control for an Integrated Primary System Reactor' focuses on operator control and protection system interaction, with particular emphasis on developing emergency response guidelines (ERGs). As in the earlier tasks, we will use the IRIS plant as a specific example of an integrated primary system reactor (IPSR) design. The present state of the IRIS plant design--specifically, the lack of a detailed secondary system design--precludes establishing detailed emergency procedures at this time. However, we can create a structure for their eventual development. This report summarizes our progress to date. Section 1.2 describes the scope of this effort. Section 2 compares IPSR ERG development to the recent AP1000 effort, and identifies three key plant differences that affect the ERGs and control room designs. The next three sections investigate these differences in more detail. Section 3 reviews the IRIS Safety-by-Design philosophy and its impact on the ERGs. Section 4 looks at differences between the IRIS and traditional loop PWR I and C Systems, and considers their implications for both control room design and ERG development. Section 5 examines the implications of having one operating staff control multiple reactor units. Section 6 provides sample IRIS emergency operating procedures (EOPs). Section 7 summarizes our conclusions

  10. Preliminary safety analysis report for the TFTR

    International Nuclear Information System (INIS)

    Lind, K.E.; Levine, J.D.; Howe, H.J.

    A Preliminary Safety Analysis Report has been prepared for the Tokamak Fusion Test Reactor. No accident scenarios have been identified which would result in exposures to on-site personnel or the general public in excess of the guidelines defined for the project by DOE

  11. Physical Activity Guidelines

    Science.gov (United States)

    ... use this site. health.gov Physical Activity Guidelines Physical Activity Physical activity is key to improving the health of the Nation. Based on the latest science, the Physical Activity Guidelines for Americans is an essential resource for ...

  12. Conceptual analysis of a preliminary model for instability study in normal operation of a natural circulation reactor type EBWR, using Relap5/Mod 3.2

    International Nuclear Information System (INIS)

    Ojeda S, J.; Morales S, J.; Chavez M, C.

    2009-10-01

    This work intends a model using the code Relap5/Mod 3.2, for the instability study in normal operation of a natural circulation reactor type ESBWR. A conceptual analysis is considered because all the information was obtained of the open literature, and some of reactor operation or dimension (not available) parameters were approached. As starting point was took the pattern developed for reactor type BWR, denominated Browns Ferry and changes were focused in elimination of bonds of forced recirculation, in modification of operation parameters, dimensions and own control parameters, according to internal code structure. Additionally the nodalization outline is described analyzing for separate the four fundamental areas employees in peculiar geometry of natural circulation reactor. Comparative analysis of results of stability behavior obtained with those reported in the open literature were made, by part of commercial reactor designer ESBWR. (Author)

  13. Visitor's Computer Guidelines | CTIO

    Science.gov (United States)

    Visitor's Computer Guidelines Network Connection Request Instruments Instruments by Telescope IR Instruments Guidelines Library Facilities Outreach NOAO-S EPO Program team Art of Darkness Image Gallery EPO/CADIAS ‹› You are here CTIO Home » Astronomers » Visitor's Computer Guidelines Visitor's Computer

  14. Index-TB Guidelines: Guidelines on extrapulmonary tuberculosis for India

    Science.gov (United States)

    Sharma, Surendra K.; Ryan, H.; Khaparde, Sunil; Sachdeva, K. S.; Singh, Achintya D.; Mohan, Alladi; Sarin, Rohit; Paramasivan, C N; Kumar, Prahlad; Nischal, Neeraj; Khatiwada, Saurav; Garner, Paul; Tharyan, Prathap

    2017-01-01

    Extrapulmonary tuberculosis (EPTB) is frequently a diagnostic and therapeutic challenge. It is a common opportunistic infection in people living with HIV/AIDS and other immunocompromised states such as diabetes mellitus and malnutrition. There is a paucity of data from clinical trials in EPTB and most of the information regarding diagnosis and management is extrapolated from pulmonary TB. Further, there are no formal national or international guidelines on EPTB. To address these concerns, Indian EPTB guidelines were developed under the auspices of Central TB Division and Directorate of Health Services, Ministry of Health and Family Welfare, Government of India. The objective was to provide guidance on uniform, evidence-informed practices for suspecting, diagnosing and managing EPTB at all levels of healthcare delivery. The guidelines describe agreed principles relevant to 10 key areas of EPTB which are complementary to the existing country standards of TB care and technical operational guidelines for pulmonary TB. These guidelines provide recommendations on three priority areas for EPTB: (i) use of Xpert MTB/RIF in diagnosis, (ii) use of adjunct corticosteroids in treatment, and (iii) duration of treatment. The guidelines were developed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) criteria, which were evidence based, and due consideration was given to various healthcare settings across India. Further, for those forms of EPTB in which evidence regarding best practice was lacking, clinical practice points were developed by consensus on accumulated knowledge and experience of specialists who participated in the working groups. This would also reflect the needs of healthcare providers and develop a platform for future research. PMID:28862176

  15. Index-TB guidelines: Guidelines on extrapulmonary tuberculosis for India

    Directory of Open Access Journals (Sweden)

    Surendra K Sharma

    2017-01-01

    Full Text Available Extrapulmonary tuberculosis (EPTB is frequently a diagnostic and therapeutic challenge. It is a common opportunistic infection in people living with HIV/AIDS and other immunocompromised states such as diabetes mellitus and malnutrition. There is a paucity of data from clinical trials in EPTB and most of the information regarding diagnosis and management is extrapolated from pulmonary TB. Further, there are no formal national or international guidelines on EPTB. To address these concerns, Indian EPTB guidelines were developed under the auspices of Central TB Division and Directorate of Health Services, Ministry of Health and Family Welfare, Government of India. The objective was to provide guidance on uniform, evidence-informed practices for suspecting, diagnosing and managing EPTB at all levels of healthcare delivery. The guidelines describe agreed principles relevant to 10 key areas of EPTB which are complementary to the existing country standards of TB care and technical operational guidelines for pulmonary TB. These guidelines provide recommendations on three priority areas for EPTB: (i use of Xpert MTB/RIF in diagnosis, (ii use of adjunct corticosteroids in treatment, and (iii duration of treatment. The guidelines were developed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE criteria, which were evidence based, and due consideration was given to various healthcare settings across India. Further, for those forms of EPTB in which evidence regarding best practice was lacking, clinical practice points were developed by consensus on accumulated knowledge and experience of specialists who participated in the working groups. This would also reflect the needs of healthcare providers and develop a platform for future research.

  16. Preliminary Electrochemical Characterization of Anode Supported Solid Oxide Cell (AS-SOC) Produced in the Institute of Power Engineering Operated in Electrolysis Mode (SOEC)

    Science.gov (United States)

    Kupecki, Jakub; Motyliński, Konrad; Skrzypkiewicz, Marek; Wierzbicki, Michał; Naumovich, Yevgeniy

    2017-12-01

    The article discusses the operation of solid oxide electrochemical cells (SOC) developed in the Institute of Power Engineering as prospective key components of power-to-gas systems. The fundamentals of the solid oxide cells operated as fuel cells (SOFC - solid oxide fuel cells) and electrolysers (SOEC - solid oxide fuel cells) are given. The experimental technique used for electrochemical characterization of cells is presented. The results obtained for planar cell with anodic support are given and discussed. Based on the results, the applicability of the cells in power-to-gas systems (P2G) is evaluated.

  17. Preliminary Calculation of the Energy Budget of the Radio Lines Orbital Method of Monitoring of Incidents caused by the Operator of the GLONASS system

    Directory of Open Access Journals (Sweden)

    Mikhail Yurievich Senatorov

    2013-12-01

    Full Text Available The calculation of the power transmitter onboard GLONASS satellites is submitted for the operation method of orbital monitoring of incidents caused by the system operator. Article is devoted to the description of actual ways of possible distribution of malwares such, as “Easter eggs”, client network applications (torrent-client and service of digital distribution. As the experiment description on distribution of malwares is provided in the simulated virtual network by means of service of digital distribution. Rules on safety of the user computers in a network are developed.

  18. A preliminary clinical trial using flowable glass-ionomer cement as a liner in proximal-ART restorations: the operator effect

    NARCIS (Netherlands)

    Bonifácio, C.C.; Hesse, D.; Bönecker, M.; van Loveren, C.; van Amerongen, W.E.; Raggio, D.P.

    2013-01-01

    .Objectives: This in vivo study was carried out to assess the influence of the operator experience on the survival rate of proximal-ART restorations using a two-layer technique to insert the glass-ionomer cement (GIC). Study Design: Forty five proximal cavities in primary molars were restored in a

  19. [A preliminary evaluation of mental status and an investigation of occupational health knowledge demand in operating and maintenance personnel in wind power plants].

    Science.gov (United States)

    Hu, S Q; Zhang, Q; Zhu, X H; Sun, K; Chen, S Z; Liu, A G; Luo, G L; Huang, W

    2016-10-20

    Objective: To investigate the mental status, level of occupational health knowledge, health behaviors, and occupational health knowledge demand in operating and maintenance personnel in wind power plants, and to provide a basis for formulating protective measures of occupational health for operating and maintenance personnel in wind power plants. Methods: A cluster sampling was performed in regionally representative wind power plants in the wind power industry from May 2014 to June 2015, and the Symptom Checklist-90 (SCL-90) and a self-made evaluation questionnaire were used to investigate the general status, mental health, and occupational health knowledge demand in 160 operating and maintenance workers. Results: Of all respondents, 26.9% had mental health issues. The awareness rate of infectious disease knowledge and preventive measures was 11.9%. Of all workers, 96.5% wanted to know the occupational hazard factors in the workplace, and 96.3% wanted to get the knowledge of the prevention of related diseases. Conclusion: Mental health issues in operating and maintenance personnel in wind power plants cannot be neglected and there is a high demand for occupational health services and related knowledge. Comprehensive intervention measures for health promotion in the workplace should be adopted to improve working environment, enhance individual mental health education, increase the level of occupational health management, and protect the health of workers.

  20. Histo-morphological findings and preliminary clinical findings after pre-operative short-term irradiation of squamous cell carcinomas of the floor of the mouth using telecobalt sources

    International Nuclear Information System (INIS)

    Dieckmann, J.; Morgenroth, K.; Hering, K.; Will, C.

    1981-01-01

    In a clinical investigation, the preoperative short-term telecobalt irradiation of patients with carcinoma of the floor of the mouth was tested. On 50 patients, the preoperative irradiation was applied after identifying the tumour by PE and fast cesion examination. Within 3 days, a focal dose of 15 to 20 Gy was applied. On the 4th day, the radical operation took place. 2-3 weeks after the operation, the saturation irradiation was carried out. For the purpose of testing, 100 patients under our usual combined treatment with radical operation plus postoperative curative telecobalt irradiation were refined to. The tissue sample before irradiation was histologically compared to the preoperatively irradiated tumour. The examinations revealed definitively a letal damage of the tumour cells. Up to the moment, the clinical results could not be received statistically because the investigation had just been finished when the draft of the speech was in preparation. But we can state, as a preliminary result, that there is a trend recognizable in which the mortality in the patients group seems to be appr. 8% lower. It is noteworthy, however, that the relapse and metastase behaviour in the group of preirradiated tumours seems to be significantly better than in the group irradiated only surgically and postoperatively: it is seen that the tumour-caused mortality in the first group is 18% less than in the latter. (orig.) [de

  1. Small Wind Site Assessment Guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, Tim [Advanced Energy Systems LLC, Eugene, OR (United States); Preus, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-09-01

    Site assessment for small wind energy systems is one of the key factors in the successful installation, operation, and performance of a small wind turbine. A proper site assessment is a difficult process that includes wind resource assessment and the evaluation of site characteristics. These guidelines address many of the relevant parts of a site assessment with an emphasis on wind resource assessment, using methods other than on-site data collection and creating a small wind site assessment report.

  2. The new hypertension guidelines.

    Science.gov (United States)

    Stern, Ralph H

    2013-10-01

    The Canadian Hypertension Education Program (CHEP) has published guidelines annually since 2000. The CHEP guidelines are a model of concise, comprehensive, up-to-date, evidence-rated guidelines for physicians who diagnose and treat hypertension. The guidelines address measurement of blood pressure and the definition of hypertension, secondary hypertension evaluation and treatment, and blood pressure targets and medication choices in patients with and without compelling indications. This review describes CHEP's process for developing guidelines and provides an overview of the 2013 recommendations. ©2013 Wiley Periodicals, Inc.

  3. Guideline of guidelines: asymptomatic microscopic haematuria.

    Science.gov (United States)

    Linder, Brian J; Bass, Edward J; Mostafid, Hugh; Boorjian, Stephen A

    2018-02-01

    The aim of the present study was to review major organizational guidelines on the evaluation and management of asymptomatic microscopic haematuria (AMH). We reviewed the haematuria guidelines from: the American Urological Association; the consensus statement by the Canadian Urological Association, Canadian Urologic Oncology Group and Bladder Cancer Canada; the American College of Physicians; the Joint Consensus Statement of the Renal Association and British Association of Urological Surgeons; and the National Institute for Health and Care Excellence. All guidelines reviewed recommend evaluation for AMH in the absence of potential benign aetiologies, with the evaluation including cystoscopy and upper urinary tract imaging. Existing guidelines vary in their definition of AMH (role of urine dipstick vs urine microscopy), the age threshold for recommending evaluation, and the optimal imaging method (computed tomography vs ultrasonography). Of the reviewed guidelines, none recommended the use of urine cytology or urine markers during the initial AMH evaluation. Patients should have ongoing follow-up after a negative initial AMH evaluation. Significant variation exists among current guidelines for AMH with respect to who should be evaluated and in what manner. Given the patient and health system implications of balancing appropriately focused and effective diagnostic evaluation, AMH represents a valuable future research opportunity. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  4. Preliminary Study of the Effect of the Proposed Long Lake Valley Project Operation on the Transport of Larval Suckers in Upper Klamath Lake, Oregon

    Science.gov (United States)

    Wood, Tamara M.

    2009-01-01

    A hydrodynamic model of Upper Klamath and Agency Lakes, Oregon, was used to explore the effects of the operation of proposed offstream storage at Long Lake Valley on transport of larval suckers through the Upper Klamath and Agency Lakes system during May and June, when larval fish leave spawning sites in the Williamson River and springs along the eastern shoreline and become entrained in lake currents. A range in hydrologic conditions was considered, including historically high and low outflows and inflows, lake elevations, and the operation of pumps between Upper Klamath Lake and storage in Long Lake Valley. Two wind-forcing scenarios were considered: one dominated by moderate prevailing winds and another dominated by a strong reversal of winds from the prevailing direction. On the basis of 24 model simulations that used all combinations of hydrology and wind forcing, as well as With Project and No Action scenarios, it was determined that the biggest effect of project operations on larval transport was the result of alterations in project management of the elevation in Upper Klamath Lake and the outflow at the Link River and A Canal, rather than the result of pumping operations. This was because, during the spring time period of interest, the amount of water pumped between Upper Klamath Lake and Long Lake Valley was generally small. The dominant effect was that an increase in lake elevation would result in more larvae in the Williamson River delta and in Agency Lake, an effect that was enhanced under conditions of wind reversal. A decrease in lake elevation accompanied by an increase in the outflow at the Link River had the opposite effect on larval concentration and residence time.

  5. Closed cooling water chemistry guidelines revision

    International Nuclear Information System (INIS)

    McElrath, Joel; Breckenridge, Richard

    2014-01-01

    This second revision of the Closed Cooling Water Chemistry Guideline addresses the use of chemicals and monitoring methods to mitigate corrosion, fouling, and microbiological growth in the closed cooling-water (CCW) systems of nuclear and fossil-fueled power plants. This revision has been endorsed by the utility chemistry community and represents another step in developing a more proactive chemistry program to limit or control closed cooling system degradation with increased consideration of corporate resources and plant-specific design and operating concerns. These guidelines were developed using laboratory data, operating experience, and input from organizations and utilities within and outside of the United States of America. It is the intent of the Revision Committee that these guidelines are applicable to all nuclear and fossil-fueled generating stations around the world. A committee of industry experts—including utility specialists, Institute of Nuclear Power Operations representatives, water-treatment service-company representatives, consultants, a primary contractor, and EPRI staff—collaborated in reviewing available data on closed cooling-water system corrosion and microbiological issues. Recognizing that each plant owner has a unique set of design, operating, and corporate concerns, the Guidelines Committee developed a methodology for plant-specific optimization. The guideline provides the technical basis for a reasonable but conservative set of chemical treatment and monitoring programs. The use of operating ranges for the various treatment chemicals discussed in this guideline will allow a power plant to limit corrosion, fouling, and microbiological growth in CCW systems to acceptable levels. The guideline now includes closed cooling chemistry regimes proven successful in use in the international community. The guideline provides chemistry constraints for the use of phosphates control, as well as pure water with pH control. (author)

  6. Vehicle recovery and towing guideline

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-01-15

    This guideline was developed to provide light and medium duty vehicles operators in the oil and gas industry with a set of best practices for avoiding injury and damage during the recovery of stuck vehicles. The aim of the guideline was to increase awareness of safety issues and promote the safe usage of the vehicles by personnel throughout the petroleum industry and to establish minimum standards of practice for vehicle recovery. The guideline included a step-by-step guide for pulling out a vehicle with a recovery strap as well as vehicle-mounted winch procedures. Pre-job checklists for both procedures were provided. Issues related to the strength rating of vehicle tow hooks and hitch receivers were discussed, as well as some of the hazards associated with steep terrains and heavy mud. The guideline also included recommendations for a vehicle recovery kit with instructions on vehicle recovery, a recovery strap, a recovery hitch and shackle, a collapsible shovel, traffic cones and reflector flares, and a heavy blanket and gloves. 7 refs., 2 tabs., 13 figs.

  7. A Preliminary Shielding Study on the Integrated Operation Verification System in the Head-End Hot-Cell of the Pyro-processing

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jinhwam; Kim, Yewon; Park, Se-Hwan; Ahn, Seong-Kyu; Cho, Gyuseong [KAIST, Daejeon (Korea, Republic of)

    2016-10-15

    Nuclear power accounts for more than 30 percent of power production in Korea. Its significance has annually been increased. Disposal spent fuel containing uranium, transuranic elements, and fission products is unavoidable byproduct of nuclear power production. it is recognized that finding appropriate sites for interim storage of disposal spent fuel is not easy because isolated sites should be required. Pyro-processing technology, Pyro-processing should be operated under high radiation environment in hot-cell structures. Because of this reason, all workers should be unauthorized to access inside the hot-cell areas under any circumstances except for acceptable dose verification and a normal operation should be remotely manipulated. For the reliable normal operation of pyroprocessing, it is noted that an evaluation of the space dose distribution in the hot-cell environments is necessary in advance in order to determine which technologies or instruments can be utilized on or near the process as the Integrated Operation Verification System (IOVS) is measured. Not like the electroreduction and electro-refining hot-cells, the head-end hot-cell equips Camera Radiation Detector (CRD) in which plutonium is securely measured and monitored for the safeguard of the pyro-processing. Results have been obtained using F2 surface tally in order to observe the magnitude of the gamma-ray and neutron flux which pass through the surface of the process cell. Furthermore, T-mesh tally has also been used to obtain the space dose distribution in the headend hot-cell. The hot-cell was divided into 7,668 cells in which each dimension was 1 x 1 x 1m for the T-mesh tally. To determine the position of the CRD and the surveillance camera, divergent approaches were required. Because the purpose of the CRD which contains a gamma-ray detector and a neutron detector is to identify the material composition as the process proceeds, the position in which detectable flux is exposed is required, whereas

  8. Neutron interrogator assay system for the Idaho Chemical Processing Plant waste canisters and spent fuel: preliminary description and operating procedures manual

    International Nuclear Information System (INIS)

    Menlove, H.O.; Eccleston, G.; Close, D.A.; Speir, L.G.

    1978-05-01

    A neutron interrogation assay system is being designed for the measurement of waste canisters and spent fuel packages at the new Idaho Chemical Processing Plant to be operated by Allied Chemical Corp. The assay samples consist of both waste canisters from the fluorinel dissolution process and spent fuel assemblies. The assay system is a 252 Cf ''Shuffler'' that employs a cyclic sequence of fast-neutron interrogation with a 252 Cf source followed by delayed-neutron counting to determine the 235 U content

  9. 23 CFR 645.109 - Preliminary engineering.

    Science.gov (United States)

    2010-04-01

    ... 23 Highways 1 2010-04-01 2010-04-01 false Preliminary engineering. 645.109 Section 645.109 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION ENGINEERING AND TRAFFIC OPERATIONS UTILITIES Utility Relocations, Adjustments, and Reimbursement § 645.109 Preliminary engineering. (a) As...

  10. Radiological risk comparison guidelines

    International Nuclear Information System (INIS)

    Hallinan, E.J.; Muhlestein, L.D.; Brown, L.F.; Yoder, R.E.

    1992-01-01

    An important aspect of DOE safety analyses is estimating potential accident risk. The estimates are used to: determine if additional controls are needed, identify Safety Class Items, and demonstrate adequate risk reduction. Thus, guidelines are needed to measure comparative risks. The Westinghouse M ampersand O Nuclear Facility Safety Committee and the Safety Envelope Working Group have developed radiological risk guidelines for comparing the risks from individual accident analyses. These guidelines were prepared under contract with the US Department of Energy. These guidelines are based on historical DOE guidelines and current requirements, and satisfy DOE and technical community proposals. for goals that demonstrate acceptable risk. The guidelines consist of a frequency versus consequence curve for credible accidents. Offsite and onsite guidelines are presented. The offsite risk acceptance guidelines are presented in Figure 1. The guidelines are nearly isorisk for anticipated events where impacts are chronic, and provide additional reduction for unlikely events where impacts may be acute and risk uncertainties may be significant. The guidelines are applied to individual release accident scenarios where a discrete frequency and consequence has been estimated. The guideline curves are not to be used for total risk assessments. Common cause events are taken into consideration only for an individual facility. Frequencies outside the guideline range are considered to be local site option (analyst judgement) as far as assessments of risk acceptance are concerned. If the curve is exceeded, then options include either a more detailed analysis or imposing additional preventive or mitigative features. Another presentation discusses implementation in detail. Additional work is needed to provide risk comparison guidelines for releases from multiple facilities and for toxic releases

  11. Environmental Survey preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    1988-04-01

    This report presents the preliminary findings from the first phase of the Environmental Survey of the United States Department of Energy (DOE) Sandia National Laboratories conducted August 17 through September 4, 1987. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with Sandia National Laboratories-Albuquerque (SNLA). The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. This phase of the Survey involves the review of existing site environmental data, observations of the operations carried on at SNLA, and interviews with site personnel. 85 refs., 49 figs., 48 tabs.

  12. ITER Operating Limits and Conditions

    International Nuclear Information System (INIS)

    Ciattaglia, S.; Barabaschi, P.; Carretero, J.A.

    2006-01-01

    The Operating Limits and Conditions (OLCs) are operating parameters and conditions, chosen among all system/components, which together define the domain of the safe operation of ITER in all foreseen ITER status (operation, maintenance, commissioning). At the same time they are selected to guarantee the required operation flexibility which is a critical factor for the success of an experimental machine such as ITER. System and components important for personnel or public safety (Safety Important Class, SIC) are identified from the overall plant safety analysis on functional importance to safety of the components. SIC classification has to be presented already inside the preliminary safety analysis report and approved by the licensing safety authority before the relevant construction. OLCs comprise the safety limits, i.e. that if exceeded could result in a potential safety hazard, the relevant settings that determine the intervention of SIC systems and the operational limits on equipment which warn from or stop a functional departure from a planned operational status that could challenge equipment and functions. The safety limits have to indicate clearly states that leave the nominal safety state of ITER; they are derived from the safety analysis of ITER. OLCs can represent in some cases few parameters grouping together. Some operational conditions, e.g. inventories, will be controlled through no real time measurements and procedures. Operating experience from present tokamaks, in particular JET, and from nuclear plants is considered at the maximum possible extent. This paper presents the guidelines to develop the ITER OLCs with particular reference to safety limits. A few examples are reported as well as open issues on some OLCs control and measurement and the relevant R-and-D planned to solve the issues. (author)

  13. Space station pressurized laboratory safety guidelines

    Science.gov (United States)

    Mcgonigal, Les

    1990-01-01

    Before technical safety guidelines and requirements are established, a common understanding of their origin and importance must be shared between Space Station Program Management, the User Community, and the Safety organizations involved. Safety guidelines and requirements are driven by the nature of the experiments, and the degree of crew interaction. Hazard identification; development of technical safety requirements; operating procedures and constraints; provision of training and education; conduct of reviews and evaluations; and emergency preplanning are briefly discussed.

  14. A tool box for operational mosquito larval control: preliminary results and early lessons from the Urban Malaria Control Programme in Dar es Salaam, Tanzania

    Directory of Open Access Journals (Sweden)

    Govella Nico J

    2008-01-01

    Full Text Available Abstract Background As the population of Africa rapidly urbanizes, large populations could be protected from malaria by controlling aquatic stages of mosquitoes if cost-effective and scalable implementation systems can be designed. Methods A recently initiated Urban Malaria Control Programme in Dar es Salaam delegates responsibility for routine mosquito control and surveillance to modestly-paid community members, known as Community-Owned Resource Persons (CORPs. New vector surveillance, larviciding and management systems were designed and evaluated in 15 city wards to allow timely collection, interpretation and reaction to entomologic monitoring data using practical procedures that rely on minimal technology. After one year of baseline data collection, operational larviciding with Bacillus thuringiensis var. israelensis commenced in March 2006 in three selected wards. Results The procedures and staff management systems described greatly improved standards of larval surveillance relative to that reported at the outset of this programme. In the first year of the programme, over 65,000 potential Anopheles habitats were surveyed by 90 CORPs on a weekly basis. Reaction times to vector surveillance at observations were one day, week and month at ward, municipal and city levels, respectively. One year of community-based larviciding reduced transmission by the primary malaria vector, Anopheles gambiae s.l., by 31% (95% C.I. = 21.6–37.6%; p = 0.04. Conclusion This novel management, monitoring and evaluation system for implementing routine larviciding of malaria vectors in African cities has shown considerable potential for sustained, rapidly responsive, data-driven and affordable application. Nevertheless, the true programmatic value of larviciding in urban Africa can only be established through longer-term programmes which are stably financed and allow the operational teams and management infrastructures to mature by learning from experience.

  15. Public informations guidelines

    International Nuclear Information System (INIS)

    1986-06-01

    The purpose of these Public Information Guidelines is to provide principles for the implementation of the NWPA mandate and the Mission Plan requirements for the provision of public information. These Guidelines set forth the public information policy to be followed by all Office of Civilian Radioactive Waste Management (OCRWM) performance components. The OCRWM offices should observe these Guidelines in shaping and conducting public information activities

  16. Public informations guidelines

    Energy Technology Data Exchange (ETDEWEB)

    None

    1986-06-01

    The purpose of these Public Information Guidelines is to provide principles for the implementation of the NWPA mandate and the Mission Plan requirements for the provision of public information. These Guidelines set forth the public information policy to be followed by all Office of Civilian Radioactive Waste Management (OCRWM) performance components. The OCRWM offices should observe these Guidelines in shaping and conducting public information activities.

  17. IMAGE Programming Guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Stehfest, E; De Waal, L.

    2010-09-15

    This document describes the requirements and guidelines for the software of the IMAGE system. The motivation for this report was a substantial restructuring of the source code for IMAGE version 2.5. The requirements and guidelines relate to design considerations as well as to aspects of maintainability and portability. The design considerations determine guidelines about subjects, such as program structure, model hierarchy, the use of data modules, and the error message system. Maintainability and portability aspects determine the guidelines on, for example, the Fortran 90 standard, naming conventions, code lay-out, and internal documentation.

  18. Guidelines for radiological interventions

    International Nuclear Information System (INIS)

    Kauffmann, G.W.

    1998-01-01

    The German Radiological Society, in cooperation with other German professional bodies, set up draft Guidelines for Radiological Interventions and submitted them to the professional community for discussion. The Guidelines are meant to assess the potential of radiological interventions as treatment alternatives to surgery or aggressive therapy such as chemotherapy. In fact, technical practicability on its own is insufficient to warrant intervention. The Guidelines are systematically compiled notions and recommendations whose aim it is to provide support to physicians and patients in choosing suitable medical care provisions (prevention, diagnosis, therapy, aftertreatment) in specific circumstances. A complete Czech translation of the Guidelines is given. (P.A.)

  19. Biomedical programs operations plans

    Science.gov (United States)

    Walbrecher, H. F.

    1974-01-01

    Operational guidelines for the space shuttle life sciences payloads are presented. An operational assessment of the medical experimental altitude test for Skylab, and Skylab life sciences documentation are discussed along with the operations posture and collection of space shuttle operational planning data.

  20. European guidelines for workplace drug testing in urine.

    Science.gov (United States)

    Taskinen, Sanna; Beck, Olof; Bosch, Tessa; Brcak, Michaela; Carmichael, Duncan; Fucci, Nadia; George, Claire; Piper, Mark; Salomone, Alberto; Schielen, Wim; Steinmeyer, Stefan; Weinmann, Wolfgang

    2017-06-01

    These European Guidelines for Workplace Drug Testing in Urine have been prepared and updated by the European Workplace Drug Testing Society (EWDTS). The first version of these urine guidelines was published in 2002. Since then, the guidelines have been followed by many laboratories in different European countries and their role has been essential particularly in countries lacking legislation for workplace drug testing. In 2014, the EWDTS started a guidelines updating project and published a new version of the urine guidelines in 2015. Here we represent this updated version of the urine guidelines. The European Guidelines are designed to establish best practice procedures whilst allowing individual countries to operate within the requirements of national customs and legislation. The EWDTS recommends that all European laboratories that undertake legally defensible workplace drug testing should use these guidelines as a template for accreditation. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  1. Soil moisture mapping using Sentinel 1 images: the proposed approach and its preliminary validation carried out in view of an operational product

    Science.gov (United States)

    Paloscia, S.; Pettinato, S.; Santi, E.; Pierdicca, N.; Pulvirenti, L.; Notarnicola, C.; Pace, G.; Reppucci, A.

    2011-11-01

    The main objective of this research is to develop, test and validate a soil moisture (SMC)) algorithm for the GMES Sentinel-1 characteristics, within the framework of an ESA project. The SMC product, to be generated from Sentinel-1 data, requires an algorithm able to process operationally in near-real-time and deliver the product to the GMES services within 3 hours from observations. Two different complementary approaches have been proposed: an Artificial Neural Network (ANN), which represented the best compromise between retrieval accuracy and processing time, thus allowing compliance with the timeliness requirements and a Bayesian Multi-temporal approach, allowing an increase of the retrieval accuracy, especially in case where little ancillary data are available, at the cost of computational efficiency, taking advantage of the frequent revisit time achieved by Sentinel-1. The algorithm was validated in several test areas in Italy, US and Australia, and finally in Spain with a 'blind' validation. The Multi-temporal Bayesian algorithm was validated in Central Italy. The validation results are in all cases very much in line with the requirements. However, the blind validation results were penalized by the availability of only VV polarization SAR images and MODIS lowresolution NDVI, although the RMS is slightly > 4%.

  2. General guidelines for recommendation of sites for nuclear waste repositories

    International Nuclear Information System (INIS)

    1983-01-01

    These guidelines were developed in accordance with the requirements of Section 112(a) of the Nuclear Waste Policy Act of 1982 for use by the Secretary of Energy in evaluating the suitability of sites for the development of repositories. The guidelines will be used for suitability evaluations and determinations made pursuant to Section 112(b) and any preliminary suitability determinations required by Section 114(f). The guidelines set forth in this Part are intended to complement the requirements set forth in the Act, 10 CFR Part 60, and 40 CFR Part 191. In applying these guidelines, the DOE will resolve any inconsistencies between these guidelines and the above documents in a manner determined by the DOE to most closely agree with the intent of the Act

  3. Preliminary results of capecitabine metronomic chemotherapy in operable triple-negative breast cancer after standard adjuvant therapy - A singlearm phase II study

    International Nuclear Information System (INIS)

    Shawky, H.; Galal, S.

    2014-01-01

    Purpose: The aim of this study is to investigate efficacy and toxicity of 1 year of capecitabine metronomic therapy preceded by standard adjuvant chemotherapy in triple-negative breast cancer (TNBC) patients. Methods: Between June 2010 and February 2012, 19 women with pathologically proven operable TNBC, who had received standard adjuvant chemotherapy before were enrolled. Patients received 1 year of oral capecitabine metronomic therapy (650 mg/m2, twice every day), after standard adjuvant chemotherapy and radiotherapy if indicated. The primary endpoints of this study were disease-free survival rates (DFS) and safety profile. Secondary end point was overall survival (OS). Results: The maximal follow-up was 46.6 months with a median of 30.1 months ±11.525 (95% CI; 28.5-33.5 months). The median DFS was 41.7 months ±2.7 (95% CI; 36.5-46.9). No one developed locoregional recurrence. The actuarial rate of DFS was 88.8% and 82.05% at 2 and 3 years, respectively. At the time of the analyses, no patients had died and the median OS was not reached. Treatment-related adverse events were manageable with only 1 patient (5.3%) suffering from Grade 3/4 hand-foot syndrome and another 1 patient (5.3%) suffering from Grade 3 diarrhea. No Grade 3/4 hematologic toxicity was recorded. All patients received full doses of capecitabine throughout the study and dose reduction was not required in any of our patients. Conclusion: One year of capecitabine metronomic therapy preceded by standard adjuvant chemotherapy, is active and well-tolerated in TNBC patients previously treated with standard adjuvant chemotherapy.

  4. Preliminary results of capecitabine metronomic chemotherapy in operable triple-negative breast cancer after standard adjuvant therapy--a single-arm phase II study.

    Science.gov (United States)

    Shawky, Hanan; Galal, Samar

    2014-12-01

    The aim of this study is to investigate efficacy and toxicity of 1 year of capecitabine metronomic therapy preceded by standard adjuvant chemotherapy in triple-negative breast cancer (TNBC) patients. Between June 2010 and February 2012, 19 women with pathologically proven operable TNBC, who had received standard adjuvant chemotherapy before were enrolled. Patients received 1 year of oral capecitabine metronomic therapy (650 mg/m2, twice every day), after standard adjuvant chemotherapy and radiotherapy if indicated. The primary endpoints of this study were disease-free survival rates (DFS) and safety profile. Secondary end point was overall survival (OS). The maximal follow-up was 46.6 months with a median of 30.1 months±11.525 (95% CI; 28.5-33.5 months). The median DFS was 41.7 months±2.7 (95% CI; 36.5-46.9). No one developed locoregional recurrence. The actuarial rate of DFS was 88.8% and 82.05% at 2 and 3 years, respectively. At the time of the analyses, no patients had died and the median OS was not reached. Treatment-related adverse events were manageable with only 1 patient (5.3%) suffering from Grade 3/4 hand-foot syndrome and another 1 patient (5.3%) suffering from Grade 3 diarrhea. No Grade 3/4 hematologic toxicity was recorded. All patients received full doses of capecitabine throughout the study and dose reduction was not required in any of our patients. One year of capecitabine metronomic therapy preceded by standard adjuvant chemotherapy, is active and well-tolerated in TNBC patients previously treated with standard adjuvant chemotherapy. Copyright © 2014. Production and hosting by Elsevier B.V.

  5. Bioassay guideline 2: guidelines for tritium bioassay

    International Nuclear Information System (INIS)

    1983-01-01

    This guideline is one of a series under preparation by the Federal-Provincial Working Group on Bioassay and In Vivo Monitoring Criteria. In this report tritium compounds have been grouped into four categories for the purpose of calculating Annual Limits on Intake and Investigation Levels: tritium gas, tritiated water, tritium-labelled compounds and nucleic acid precursors

  6. 10 CFR 960.4-1 - System guideline.

    Science.gov (United States)

    2010-01-01

    ... DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE... at the site shall allow for the physical separation of radioactive waste from the accessible environment after closure in accordance with the requirements of 40 CFR part 191, subpart B, as implemented by...

  7. Evidence-based guidelines

    DEFF Research Database (Denmark)

    Rovira, Àlex; Wattjes, Mike P; Tintoré, Mar

    2015-01-01

    diagnosis in patients with MS. The aim of this article is to provide guidelines for the implementation of MRI of the brain and spinal cord in the diagnosis of patients who are suspected of having MS. These guidelines are based on an extensive review of the recent literature, as well as on the personal...

  8. Whitebark pine planting guidelines

    Science.gov (United States)

    Ward McCaughey; Glenda L. Scott; Kay L. Izlar

    2009-01-01

    This article incorporates new information into previous whitebark pine guidelines for planting prescriptions. Earlier 2006 guidelines were developed based on review of general literature, research studies, field observations, and standard US Forest Service survival surveys of high-elevation whitebark pine plantations. A recent study of biotic and abiotic factors...

  9. Guidelines for Learning Stations.

    Science.gov (United States)

    Fehrle, Carl C.; Schulz, Jolene

    Guidelines for designing and planning learning stations for pupils at the elementary grade level include suggestions on how to develop a station that will be successful in meeting the learners' needs. Instructions for the use of tapes at a station and matching pupils with stations are given, as are guidelines on classroom arrangement and record…

  10. D 59 Design Guidelines

    DEFF Research Database (Denmark)

    Burcharth, Hans F.; Lamberti, Alberto

    The present guidelines are specifically dedicated to Low Crested Structures on attempt to provide methodological tools both for the engineering design of structures and for prediction of performance and environmental impacts. It is anticipated that the guidelines will provide valuable inputs to c...

  11. Measure Guideline: Ventilation Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Springer, D. [Alliance for Residential Building Innovation (ARBI), David, CA (United States); Dakin, B. [Alliance for Residential Building Innovation (ARBI), David, CA (United States); German, A. [Alliance for Residential Building Innovation (ARBI), David, CA (United States)

    2012-04-01

    The purpose of this measure guideline is to provide information on a cost-effective solution for reducing cooling system energy and demand in homes located in hot-dry and cold-dry climates. This guideline provides a prescriptive approach that outlines qualification criteria, selection considerations, and design and installation procedures.

  12. Maintenance Trades Guidelines

    Science.gov (United States)

    Weidner, Theodore J.

    2008-01-01

    In 2002, APPA published "Maintenance Staffing Guidelines for Educational Facilities," the first building maintenance trades staffing guideline designed to assist educational facilities professionals with their staffing needs. addresses how facilities professionals can determine the appropriate size and mix of their organization. Contents…

  13. Primary care guidelines

    DEFF Research Database (Denmark)

    Ijäs, Jarja; Alanen, Seija; Kaila, Minna

    2009-01-01

    OBJECTIVE: To describe the adoption of the national Hypertension Guideline in primary care and to evaluate the consistency of the views of the health centre senior executives on the guideline's impact on clinical practices in the treatment of hypertension in their health centres. DESIGN: A cross...... Guideline. RESULTS: Data were available from 143 health centres in Finland (49%). The views of head physicians and senior nursing officers on the adoption of the Hypertension Guideline were not consistent. Head physicians more often than senior nursing officers (44% vs. 29%, p ...: Hypertension Guideline recommendations that require joint agreements between professionals are less often adopted than simple, precise recommendations. More emphasis on effective multidisciplinary collaboration is needed....

  14. Global Imaging referral guidelines

    International Nuclear Information System (INIS)

    Kawooya, M.; Perez, M.; Lau, L.; Reeed, M.

    2010-01-01

    The medical imaging specialists called for global referral guidelines which would be made available to referring doctors. These referral guidelines should be:- Applicable in different health care settings, including resource-poor settings; Inclusive in terms of the range of clinical conditions; User-friendly and accessible (format/media); Acceptable to stakeholders, in particular to the referrers as the main target audience. To conceive evidence-based medicine as an integration of best research evidence with clinical expertise and patient values. The Direct recipients of the Referral Guidelines would be:- Referrers: general practitioners / family doctors; paediatricians; emergency department doctors; other specialists and health workers. Providers (medical imaging practitioners): radiologists; nuclear medicine physicians; radiographers; other appropriately qualified practitioners providing diagnostic imaging services. For the Referral Guidelines to be effective there need to be: Credibility evidence-based Practicality end user involvement Context local resources, disease profiles Endorsement, opinion leaders Implementation- policy, education, CPOE - Monitoring of the use clinical audit, report feedback. The aim of the Referral Guidelines Project was to: Produce global referral guidelines that are evidence-based, cost effective and appropriate for the local setting, and include consideration of available equipment and expertise (RGWG; SIGs); Include supporting information about radiation doses, potential risks, protection of children and pregnant women (introductory chapter); Facilitate the implementation of the guidelines through guidance and tools (e.g. implementation guides, checklists, capacity building tools, guides on stakeholders engagement, audit support criteria); Conduct pilot testing in different clinical settings from each of the six WHO regions; Promote the inclusion of the referral guidelines in the curricula of medical schools; Develop and implement

  15. Preliminary evidences of CCM operation and its down regulation in relation to increasing CO2 levels in natural phytoplankton assemblages from the coastal waters of Bay of Bengal

    Science.gov (United States)

    Biswas, Haimanti; Rahman Shaik, Aziz Ur; Bandyopadhyay, Debasmita

    2014-05-01

    levels, CA activity was enhanced and accelerated DIC transport and photosynthetic rate. Moreover, δ13CPOM values of low CO2 samples (both Zn treated and untreated) were almost identical, though the rate of photosynthesis was higher in response to Zn addition. This could be because of the fact that under low CO2 levels, DIC was possibly transported as HCO3- and an active HCO3- transport can contribute to low discrimination of 13C compared to diffusive CO2uptake leading to unaltered values of δ13CPOM. Furthermore, under low CO2 treatments, the need of nitrogen resource can be higher to maintain an active CCM (to build-up required proteins, Rubisco and CCM components) and our results showed higher values of δ15NPOMunder low CO2 levels relative to the high CO2treatments suggesting higher nitrogen utilization efficiency in the former case. These observations strengthen the possibility of operating an active CCM under low CO2 levels. HPLC pigment analysis revealed the occurrences of diatoxanthin (DT) [indicator of non-photo-chemical quenching (NPQ)] and high values of photoprotective carotenoid to light harvesting carotenoid ratios (PPC/LHC) in the low CO2 treated cells indicating light stress. This is likely that, when CO2, the only substrate for Rubisco, is low, absorbed light energy within the cell can be surplus leading to photo-damage and to protect the cell from potential damage, DT was produced by energy dissipation via NPQ and PPC were synthesized in excess of LHC. Conversely, in Zn and high CO2 treated cells, the absence of DT and reduced values of PPC/LHC indirectly indicates reduced light stress which was possibly because of enhanced supply of Rubisco substrate either via active bicarbonate transport or diffusive CO2 supply. Thus, we infer that the diatom dominated phytoplankton communities from the study area perform CCMs under low CO2 conditions and the same can be down regulated upon the increasing levels of CO2 and the community may benefit from the

  16. Pre-Operative Planning Using Real-Time Virtual Sonography, an MRI/Ultrasound Image Fusion Technique, for Breast-Conserving Surgery in Patients with Non-Mass Enhancement on Breast MRI: A Preliminary Study.

    Science.gov (United States)

    Ando, Takahito; Ito, Yukie; Ido, Mirai; Osawa, Manami; Kousaka, Junko; Mouri, Yukako; Fujii, Kimihito; Nakano, Shogo; Kimura, Junko; Ishiguchi, Tsuneo; Watanebe, Rie; Imai, Tsuneo; Fukutomi, Takashi

    2018-07-01

    The purpose of this retrospective study was to evaluate the effect of pre-operative planning using real-time virtual sonography (RVS), a magnetic resonance imaging (MRI)/ultrasound (US) image fusion technique on breast-conserving surgery (BCS) in patients with non-mass enhancement (NME) on breast MRI. Between 2011 and 2015, we enrolled 12 consecutive patients who had lesions with NME that exceeded the US hypo-echoic area, in which it was particularly difficult to evaluate the tumor margin. During pre-operative planning before breast-conserving surgery, RVS was used to delineate the enhancing area on the breast surface after additional supine breast MRI was performed. We analyzed both the surgical margin positivity rate and the re-operation rate. All NME lesions corresponded to the index cancer. In all patients, the diameter of the NME lesion was greater than that of the hypo-echoic lesion. The median diameters of the NME and hypo-echoic lesions were 24 mm (range: 12-39 mm) and 8.0 mm (range: 4.9-18 mm), respectively (p = 0.0002). After RVS-derived skin marking was performed on the surface of the affected breast, lumpectomy and quadrantectomy were conducted in 7 and 5 patients, respectively. The surgical margins were negative in 10 (83%) patients. Two patients with positive margins were found to have ductal carcinoma in situ in 1 duct each, 2.4 and 3.2 mm from the resection margin, respectively. None of the patients required additional resection. Although further prospective studies are required, the findings of our preliminary study suggest that it is very well possible that the use of RVS-derived skin marking during pre-operative planning for BCS in patients with NME would have resulted in surgical outcomes similar to or better than those obtained without the use of such marking. Copyright © 2018. Published by Elsevier Inc.

  17. K-Basins design guidelines

    International Nuclear Information System (INIS)

    Roe, N.R.; Mills, W.C.

    1995-06-01

    The purpose of the design guidelines is to enable SNF and K Basin personnel to complete fuel and sludge removal, and basin water mitigation by providing engineering guidance for equipment design for the fuel basin, facility modifications (upgrades), remote tools, and new processes. It is not intended to be a purchase order reference for vendors. The document identifies materials, methods, and components that work at K Basins; it also Provides design input and a technical review process to facilitate project interfaces with operations in K Basins. This document is intended to compliment other engineering documentation used at K Basins and throughout the Spent Nuclear Fuel Project. Significant provisions, which are incorporated, include portions of the following: General Design Criteria (DOE 1989), Standard Engineering Practices (WHC-CM-6-1), Engineering Practices Guidelines (WHC 1994b), Hanford Plant Standards (DOE-RL 1989), Safety Analysis Manual (WHC-CM-4-46), and Radiological Design Guide (WHC 1994f). Documents (requirements) essential to the engineering design projects at K Basins are referenced in the guidelines

  18. Guidelines for evaluation of the environmental expense

    International Nuclear Information System (INIS)

    Komatsu, Cintia Nagako; Aquino, Afonso Rodrigues de

    2009-01-01

    The main objective of this research is to establish guidelines to fit the Environment Account in the Nuclear Fuel Cycle, using as study of case the Uranium Hexafluoride Production Unit of Centro Tecnologico da Marinha in Sao Paulo. The environment accounting, branch of the accounting science, supply a source of tools capable to measure the protection efforts, the nature preservation, the environment monitoring and the recovering during all the Conversion phase (since the Uranium concentrated, the yellow cake, up to the Uranium hexafluoride production). It was performed several researches, visits to the Centre, databank creation, interviews and extensive consulting to the preliminary safety report, in order to obtain the percentage of the total expenses related to environment protection in regarding to the total amount invested in the unit. It was also evaluated the total preserved green area making possible a preliminary environment accounting balance. (author)

  19. EPRI PWR primary water chemistry guidelines revision

    International Nuclear Information System (INIS)

    McElrath, Joel; Fruzzetti, Keith

    2014-01-01

    EPRI periodically updates the PWR Primary Water Chemistry Guidelines as new information becomes available and as required by NEI 97-06 (Steam Generator Program Guidelines) and NEI 03-08 (Guideline for the Management of Materials Issues). The last revision of the PWR water chemistry guidelines identified an optimum primary water chemistry program based on then-current understanding of research and field information. This new revision provides further details with regard to primary water stress corrosion cracking (PWSCC), fuel integrity, and shutdown dose rates. A committee of industry experts, including utility specialists, nuclear steam supply system (NSSS) and fuel vendor representatives, Institute of Nuclear Power Operations (INPO) representatives, consultants, and EPRI staff collaborated in reviewing the available data on primary water chemistry, reactor water coolant system materials issues, fuel integrity and performance issues, and radiation dose rate issues. From the data, the committee updated the water chemistry guidelines that all PWR nuclear plants should adopt. The committee revised guidance with regard to optimization to reflect industry experience gained since the publication of Revision 6. Among the changes, the technical information regarding the impact of zinc injection on PWSCC initiation and dose rate reduction has been updated to reflect the current level of knowledge within the industry. Similarly, industry experience with elevated lithium concentrations with regard to fuel performance and radiation dose rates has been updated to reflect data collected to date. Recognizing that each nuclear plant owner has a unique set of design, operating, and corporate concerns, the guidelines committee has retained a method for plant-specific optimization. Revision 7 of the Pressurized Water Reactor Primary Water Chemistry Guidelines provides guidance for PWR primary systems of all manufacture and design. The guidelines continue to emphasize plant

  20. EMI Messaging Guidelines

    CERN Document Server

    Cons, L.

    2011-01-01

    Guidelines for potential users of messaging within EMI. The goal is to provide enough practical information so that EMI product teams can start investigating whether using messaging in their products can be beneficial or not.

  1. London 2012 packaging guidelines

    OpenAIRE

    2013-01-01

    These guidelines are intended to provide supplemental advice to suppliers and licensees regarding the provisions of the LOCOG Sustainable Sourcing Code that relate to packaging design and materials selection.

  2. Curriculum Guidelines for Periodontics.

    Science.gov (United States)

    Journal of Dental Education, 1985

    1985-01-01

    Guidelines describe the interrelationships of this and other dental fields, give an overview of the curriculum and its primary educational objectives, and outline the suggested prerequisites, core content, specific behavioral objectives, sequencing, and faculty requirements. (MSE)

  3. Transparent Guideline Methodology Needed

    DEFF Research Database (Denmark)

    Lidal, Ingeborg; Norén, Camilla; Mäkelä, Marjukka

    2013-01-01

    As part of learning at the Nordic Workshop of Evidence-based Medicine, we have read with interest the practice guidelines for central venous access, published in your Journal in 2012.1 We appraised the quality of this guideline using the checklist developed by The Evidence-Based Medicine Working ...... are based on best currently available evidence. Our concerns are in two main categories: the rigor of development, including methodology of searching, evaluating, and combining the evidence; and editorial independence, including funding and possible conflicts of interest....... Group.2 Similar criteria for guideline quality have been suggested elsewhere.3 Our conclusion was that this much needed guideline is currently unclear about several aspects of the methodology used in developing the recommendations. This means potential users cannot be certain that the recommendations...

  4. Adopting preoperative fasting guidelines.

    Science.gov (United States)

    Anderson, Megan; Comrie, Rhonda

    2009-07-01

    In 1999, the American Society of Anesthesiologists adopted preoperative fasting guidelines to enhance the quality and efficiency of patient care. Guidelines suggest that healthy, non-pregnant patients should fast six hours from solids and two hours from liquids. Although these guidelines are in place, studies suggest that providers are still using the blanket statement "NPO after midnight" without regard to patient characteristics, the procedure, or the time of the procedure. Using theory to help change provider's beliefs may help make change more successful. Rogers' Theory of Diffusion of Innovations can assist in changing long-time practice by laying the groundwork for an analysis of the benefits and disadvantages of proposed changes, such as changes to fasting orders, while helping initiate local protocols instead of additional national guidelines.

  5. Condensate polishing guidelines for PWR and BWR plants

    International Nuclear Information System (INIS)

    Robbins, P.; Crinigan, P.; Graham, B.; Kohlmann, R.; Crosby, C.; Seager, J.; Bosold, R.; Gillen, J.; Kristensen, J.; McKeen, A.; Jones, V.; Sawochka, S.; Siegwarth, D.; Keeling, D.; Polidoroff, T.; Morgan, D.; Rickertsen, D.; Dyson, A.; Mills, W.; Coleman, L.

    1993-03-01

    Under EPRI sponsorship, an industry committee, similar in form and operation to other guideline committees, was created to develop Condensate Polishing Guidelines for both PWR and BWR systems. The committee reviewed the available utility and water treatment industry experience on system design and performance and incorporated operational and state-of-the-art information into document. These guidelines help utilities to optimize present condensate polisher designs as well as be a resource for retrofits or new construction. These guidelines present information that has not previously been presented in any consensus industry document. The committee generated guidelines that cover both deep bed and powdered resin systems as an integral part of the chemistry of PWR and BWR plants. The guidelines are separated into sections that deal with the basis for condensate polishing, system design, resin design and application, data management and performance and management responsibilities

  6. Electrical safety guidelines

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-01

    The Electrical Safety Guidelines prescribes the DOE safety standards for DOE field offices or facilities involved in the use of electrical energy. It has been prepared to provide a uniform set of electrical safety standards and guidance for DOE installations in order to affect a reduction or elimination of risks associated with the use of electrical energy. The objectives of these guidelines are to enhance electrical safety awareness and mitigate electrical hazards to employees, the public, and the environment.

  7. Lageos assembly operation plan

    Science.gov (United States)

    Brueger, J.

    1975-01-01

    Guidelines and constraints procedures for LAGEOS assembly, operation, and design performance are given. Special attention was given to thermal, optical, and dynamic analysis and testing. The operation procedures illustrate the interrelation and sequence of tasks in a flow diagram. The diagram also includes quality assurance functions for verification of operation tasks.

  8. Ecologo guidelines spark disagreement

    International Nuclear Information System (INIS)

    Anon.

    1999-01-01

    Defining what renewable means has been a challenge, but the authors of a new set of guidelines for the Ecologo certification of renewable low-impact electrcity expect after some delay to have the new rules on the street by March 2000.. There was contention in developing the guideline, according to Terra Choice Environmental Services, the company that created and applied criteria for Ecologo certification under the federal government's Environmetal Choice Program. Interim guidleines were developed and have been in place for renewable power since 1996, and have since been used to certify wood-waste biomass, landfill gas, small hydro and wind power plants, in addition to three green power marketing programs. The first draft of the revised guidelines was issued in March. It was one of the harder guidelines to have been worked on because Canadian power producers did not readily agree on what should qualify as renewable, particularly around the whole area of hydro. While small run-of-river hydro plants will continue to fit within the Ecologo guidelines, larger projects will not. Wind power producers are relatively happy with the latest version of TerraChoice's draft guidelines, released at the end of November. A significant revision of the original rules is a limit on the amount of older generation green power marketers who want to promote the green power Ecologo electricity can sell. At least 50% of their capacity must originate from plants installed after January 1, 1991

  9. Web Accessibility and Guidelines

    Science.gov (United States)

    Harper, Simon; Yesilada, Yeliz

    Access to, and movement around, complex online environments, of which the World Wide Web (Web) is the most popular example, has long been considered an important and major issue in the Web design and usability field. The commonly used slang phrase ‘surfing the Web’ implies rapid and free access, pointing to its importance among designers and users alike. It has also been long established that this potentially complex and difficult access is further complicated, and becomes neither rapid nor free, if the user is disabled. There are millions of people who have disabilities that affect their use of the Web. Web accessibility aims to help these people to perceive, understand, navigate, and interact with, as well as contribute to, the Web, and thereby the society in general. This accessibility is, in part, facilitated by the Web Content Accessibility Guidelines (WCAG) currently moving from version one to two. These guidelines are intended to encourage designers to make sure their sites conform to specifications, and in that conformance enable the assistive technologies of disabled users to better interact with the page content. In this way, it was hoped that accessibility could be supported. While this is in part true, guidelines do not solve all problems and the new WCAG version two guidelines are surrounded by controversy and intrigue. This chapter aims to establish the published literature related to Web accessibility and Web accessibility guidelines, and discuss limitations of the current guidelines and future directions.

  10. Main-coolant-pump shaft-seal guidelines. Volume 1. Maintenance-manual guidelines. Final report

    International Nuclear Information System (INIS)

    Fair, C.E.; Greer, A.O.

    1983-03-01

    This report presents a set of guidelines and a listing of information and data which should be included in maintenance manuals and procedures for Main Coolant Pump Shaft Seals. The noted guidelines and data listing are developed from EPRI sponsored nuclear plant seal operating experience studies. The maintenance oriented results of the most recent such study is summarized. The shaft seal and its auxiliary supporting systems are discussed from both technical and maintenance related viewpoints

  11. Preliminary assessment of risk of ozone impacts to maize (Zea mays) in Southern Africa

    CSIR Research Space (South Africa)

    Van Tienhoven, AM

    2006-03-01

    Full Text Available Surface ozone concentrations in southern Africa exceed air quality guidelines set to protect agricultural crops. This paper addresses a knowledge gap by performing a preliminary assessment of potential ozone impacts on vegetation in southern African...

  12. Preliminary rail access study

    International Nuclear Information System (INIS)

    1990-01-01

    The Yucca Mountain site, located on the southwestern edge of the Nevada Test Site, is an undeveloped area under investigation as a potential site for nuclear waste disposal by the US Department of Energy. The site currently lacks rail service and an existing rail right-of-way. If the site is suitable and selected for development as a disposal site, rail service is desirable to the Office of Civilian Radioactive Waste Management Program because of the potential of rail to reduce number of shipments and costs relative to highway transportation. This preliminary report is a summary of progress to date for activities to identify and evaluate potential rail options from major rail carriers in the region to the Yucca Mountain site. It is currently anticipated that the rail spur will be operational after the year 2000. 9 refs., 13 figs., 2 tabs

  13. Effects prediction guidelines for structures subjected to ground motion

    International Nuclear Information System (INIS)

    1975-07-01

    Part of the planning for an underground nuclear explosion (UNE) is determining the effects of expected ground motion on exposed structures. Because of the many types of structures and the wide variation in ground motion intensity typically encountered, no single prediction method is both adequate and feasible for a complete evaluation. Furthermore, the nature and variability of ground motion and structure damage prescribe effects predictions that are made probabilistically. Initially, prediction for a UNE involves a preliminary assessment of damage to establish overall project feasibility. Subsequent efforts require more detailed damage evaluations, based on structure inventories and analyses of specific structures, so that safety problems can be identified and safety and remedial measures can be recommended. To cover this broad range of effects prediction needs for a typical UNE project, three distinct but interrelated methods have been developed and are described. First, the fundamental practical and theoretical aspects of predicting the effects of dynamic ground motion on structures are summarized. Next, experimentally derived and theoretically determined observations of the behavior of typical structures subjected to ground motion are presented. Then, based on these fundamental considerations and on the observed behavior of structures, the formulation of the three effects prediction procedures is described, along with guidelines regarding their applicability. Example damage predictions for hypothetical UNEs demonstrate these procedures. To aid in identifying the vibration properties of complex structures, one chapter discusses alternatives in vibration testing, instrumentation, and data analysis. Finally, operational guidelines regarding data acquisition procedures, safety criteria, and remedial measures involved in conducting structure effects evaluations are discussed. (U.S.)

  14. 78 FR 277 - Section 610 Review of NPDES Permit Regulation and Effluent Limitations Guidelines Standards for...

    Science.gov (United States)

    2013-01-03

    ..., Section 610 Review of NPDES Permit Regulation and Effluent Limitations Guidelines Standards for..., FRL-9764-8] Section 610 Review of NPDES Permit Regulation and Effluent Limitations Guidelines Standards for Concentrated Animal Feeding Operations (CAFOs); Extension of Comment Period AGENCY...

  15. Montana Curriculum Guidelines for Distributive Education. Revised.

    Science.gov (United States)

    Harris, Ron, Ed.

    These distributive education curriculum guidelines are intended to provide Montana teachers with teaching information for 11 units. Units cover introduction to marketing and distributive education, human relations and communications, operations and control, processes involved in buying for resale, merchandise handling, sales promotion, sales and…

  16. Measure Guideline: Window Repair, Rehabilitation, and Replacement

    Energy Technology Data Exchange (ETDEWEB)

    Baker, P.

    2012-12-01

    This measure guideline provides information and guidance on rehabilitating, retrofitting, and replacing existing window assemblies in residential construction. The intent is to provide information regarding means and methods to improve the energy and comfort performance of existing wood window assemblies in a way that takes into consideration component durability, in-service operation, and long term performance of the strategies.

  17. Preliminary Monthly Climatological Summaries

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Preliminary Local Climatological Data, recorded since 1970 on Weather Burean Form 1030 and then National Weather Service Form F-6. The preliminary climate data pages...

  18. Guidelines and workbook for of organization and administration of utilities seeking operating license for a nuclear power plant. Workbook for assessment of organization and management. Volume, 2, Revision 1

    International Nuclear Information System (INIS)

    Thurber, J.A.; Olson, J.; Osborn, R.N.; Sommers, P.; Widrig, R.D.

    1986-09-01

    This report is a partial response to the requirements of Item I.B.1.1 of the ''NRC Action Plan Developed as a Result of the TMI-2 Accident,'' NUREG-0660, and is designed to serve as a basis for replacing the earlier NUREG-0731, ''Guidelines for Utility Management Structure and Technical Resources.'' The Guidelines are intended to provide guidance to the user in preparing a written plan for a proposed nuclear organization and administration. The purpose of the Workbook is to guide the NRC reviewer through a systematic review and assessment of a proposed organization and administration. It is the NRC's intention to incorporate these Guidelines and Workbook into a future revision of the Standard Review Plan (SRP), NUREG-0800. However, at this time the report is being published so that the material may be used on a voluntary basis by industry to systematically prepare or evaluate their organization or administration plans. Use of the report by the NRC would not occur until after it has been incorporated in the SRP

  19. Guidelines for nuclear reactor equipments safety-analysis

    International Nuclear Information System (INIS)

    1978-01-01

    The safety analysis in approving the applications for nuclear reactor constructions (or alterations) is performed by the Committee on Examination of Reactor Safety in accordance with various guidelines prescribed by the Atomic Energy Commission. In addition, the above Committee set forth its own regulations for the safety analysis on common problems among various types of nuclear reactors. This book has collected and edited those guidelines and regulations. It has two parts: Part I includes the guidelines issued to date by the Atomic Energy Commission: and Part II - regulations of the Committee. Part I has collected 8 categories of guidelines which relate to following matters: nuclear reactor sites analysis guidelines and standards for their applications; standard exposure dose of plutonium; nuclear ship operation guidelines; safety design analysis guidelines for light-water type, electricity generating nuclear reactor equipments; safety evaluation guidelines for emergency reactor core cooling system of light-water type power reactors; guidelines for exposure dose target values around light-water type electricity generating nuclear reactor equipments, and guidelines for evaluation of above target values; and meteorological guidelines for the safety analysis of electricity generating nuclear reactor equipments. Part II includes regulations of the Committee concerning - the fuel assembly used in boiling-water type and in pressurized-water type reactors; techniques of reactor core heat designs, etc. in boiling-water reactors; and others

  20. Design patterns for modelling guidelines

    NARCIS (Netherlands)

    Serban, Radu; Ten Teije, Annette; Marcos, Mar; Polo-Conde, Cristina; Rosenbrand, Kitty C J G M; Wittenberg, Jolanda; van Croonenborg, Joyce

    2005-01-01

    It is by now widely accepted that medical guidelines can help to significantly improve the quality of medical care. Unfortunately, constructing the required medical guidelines is a very labour intensive and costly process. The cost of guideline construction would decrease if guidelines could be

  1. Development of cancer treatment guidelines

    African Journals Online (AJOL)

    Krystyna Kiel

    2011-05-26

    May 26, 2011 ... KEYWORDS. Cancer;. Therapy;. Guidelines. Contents. 1. Why develop guidelines? ... Widely available guideline resources in cancer care. ... The use of guidelines in medicine has a long history. Many .... She has a negative family history. ... The patient has 1 cm grade 3 infiltrating ductal carcinoma.

  2. Japanese Guideline for Atopic Dermatitis

    Directory of Open Access Journals (Sweden)

    Ichiro Katayama

    2011-01-01

    The basics of treatment discussed in this guideline are based on the “Guidelines for the Treatment of Atopic Dermatitis 2008” prepared by the Health and Labour Sciences Research and the “Guidelines for the Management of Atopic Dermatitis 2009 (ADGL2009” prepared by the Atopic Dermatitis Guidelines Advisory Committee, Japanese Society of Allergology in principle.

  3. Are BTS guidelines followed?

    Science.gov (United States)

    2002-03-01

    In 1993, the British Thoracic Society (BTS) issued guidelines for the management of spontaneous pneumothorax. The study's aim was to determine the level of adherence to these guidelines at a London teaching hospital. A retrospective case note audit of 59 episodes was performed. In patients undergoing intervention, the initial procedure was simple aspiration in 32 (73 per cent) and chest tube insertion in 12 (27 per cent) cases, contrasting with the BTS recommendation that aspiration should be attempted first in all such patients. Simple aspiration was successful on 34 per cent of occasions. Successful aspiration was associated with a significantly shorter hospital stay (median 3, range 1-11 days) than either failed aspiration (7, 3-66 days) or chest tube insertion without aspiration (9, 3-16 days). Other areas where practice differed from the BTS guidelines were clamping of chest tubes and use of a pursestring suture for wound closure. A follow up questionnaire suggested a lack of familiarity with the guidelines. These findings indicate that current management of spontaneous pneumothorax deviates from the BTS guidelines in potentially important respects.

  4. Versator divertor experiment: preliminary designs

    International Nuclear Information System (INIS)

    Wan, A.S.; Yang, T.F.

    1984-08-01

    The emergence of magnetic divertors as an impurity control and ash removal mechanism for future tokamak reactors bring on the need for further experimental verification of the divertor merits and their ability to operate at reactor relevant conditions, such as with auxiliary heating. This paper presents preliminary designs of a bundle and a poloidal divertor for Versator II, which can operate in conjunction with the existing 150 kW of LHRF heating or LH current drive. The bundle divertor option also features a new divertor configuration which should improve the engineering and physics results of the DITE experiment. Further design optimization in both physics and engineering designs are currently under way

  5. OSART guidelines. 1994 edition

    International Nuclear Information System (INIS)

    1994-05-01

    These guidelines have been prepared to provide a basic structure and common reference both across the various areas covered by an OSART mission and across all the missions in the programme. As such, they are addressed, principally, to the team members of OSART missions but they will also provide guidance to a host nuclear plant preparing to receive a mission. The guidelines are intended to help each expert to formulate his review in the light of this own experience. They are not all inclusive and should not limit the expert's investigations, but are better considered as illustrating the adequate requirements for his review

  6. Data Qualification guidelines

    International Nuclear Information System (INIS)

    Edwards, T.B.; Shine, E.P.

    1992-01-01

    Data Qualification (DQ) is a formal, technical process whose objective is to affirm that experimental data are suitable for their intended use. Although it is not possible to develop a fixed recipe for the DQ process to cover all test situations, these general guidelines have been developed for the Nuclear Engineering Section to establish a framework for qualifying data from steady-state processing. These guidelines outline the role of the DQ team providing insight into the planning and conducting of the DQ process

  7. Strategy Guideline: Demonstration Home

    Energy Technology Data Exchange (ETDEWEB)

    Savage, C.; Hunt, A.

    2012-12-01

    This guideline will provide a general overview of the different kinds of demonstration home projects, a basic understanding of the different roles and responsibilities involved in the successful completion of a demonstration home, and an introduction into some of the lessons learned from actual demonstration home projects. Also, this guideline will specifically look at the communication methods employed during demonstration home projects. And lastly, we will focus on how to best create a communication plan for including an energy efficient message in a demonstration home project and carry that message to successful completion.

  8. Strategy Guideline. Demonstration Home

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, A.; Savage, C.

    2012-12-01

    This guideline will provide a general overview of the different kinds of demonstration home projects, a basic understanding of the different roles and responsibilities involved in the successful completion of a demonstration home, and an introduction into some of the lessons learned from actual demonstration home projects. Also, this guideline will specifically look at the communication methods employed during demonstration home projects. And lastly, we will focus on how to best create a communication plan for including an energy efficient message in a demonstration home project and carry that message to successful completion.

  9. PWR secondary water chemistry guidelines: Revision 3

    International Nuclear Information System (INIS)

    Lurie, S.; Bucci, G.; Johnson, L.; King, M.; Lamanna, L.; Morgan, E.; Bates, J.; Burns, R.; Eaker, R.; Ward, G.; Linnenbom, V.; Millet, P.; Paine, J.P.; Wood, C.J.; Gatten, T.; Meatheany, D.; Seager, J.; Thompson, R.; Brobst, G.; Connor, W.; Lewis, G.; Shirmer, R.; Gillen, J.; Kerns, M.; Jones, V.; Lappegaard, S.; Sawochka, S.; Smith, F.; Spires, D.; Pagan, S.; Gardner, J.; Polidoroff, T.; Lambert, S.; Dahl, B.; Hundley, F.; Miller, B.; Andersson, P.; Briden, D.; Fellers, B.; Harvey, S.; Polchow, J.; Rootham, M.; Fredrichs, T.; Flint, W.

    1993-05-01

    An effective, state-of-the art secondary water chemistry control program is essential to maximize the availability and operating life of major PWR components. Furthermore, the costs related to maintaining secondary water chemistry will likely be less than the repair or replacement of steam generators or large turbine rotors, with resulting outages taken into account. The revised PWR secondary water chemistry guidelines in this report represent the latest field and laboratory data on steam generator corrosion phenomena. This document supersedes Interim PWR Secondary Water Chemistry Recommendations for IGA/SCC Control (EPRI report TR-101230) as well as PWR Secondary Water Chemistry Guidelines--Revision 2 (NP-6239)

  10. Medical guidelines for the patient: introducing the life assistance protocols.

    Science.gov (United States)

    Domínguez, David; Fernández, Carlos; Meneu, Teresa; Mocholí, Juan Bautista; Serafin, Riccardo

    2008-01-01

    This paper introduces our preliminary results in the modeling of Life Assistance Protocols, a new vision of medical guidelines and protocols through the lenses of p-Health. In this context the patient's role in the process is emphasized, the actions to be performed less defined and not only clinical situations considered, but also healthier lifestyle promotion processes accounted for, where the person's preferences and motivations play a key role. We propose a complete framework, balancing on classical clinical guideline models and covering both the theoretical and the practical aspects of the problem, describing it from conceptualization to the execution environment.

  11. Joint IAEA/NEA IRS guidelines

    International Nuclear Information System (INIS)

    1997-01-01

    The Incident Reporting System (IRS) is an international system jointly operated by the International Atomic Energy Agency (IAEA) and the Nuclear Energy Agency of the Organization for Economic Cooperation and Development (OECD/NEA). The fundamental objective of the IRS is to contribute to improving the safety of commercial nuclear power plants (NPPs) which are operated worldwide. This objective can be achieved by providing timely and detailed information on both technical and human factors related to events of safety significance which occur at these plants. The purpose of these guidelines, which supersede the previous IAEA Safety Series No. 93 (Part II) and the NEA IRS guidelines, is to describe the system and to give users the necessary background and guidance to enable them to produce IRS reports meeting a high standard of quality while retaining the high efficiency of the system expected by all Member States operating nuclear power plants

  12. Instructional Guidelines. Welding.

    Science.gov (United States)

    Fordyce, H. L.; Doshier, Dale

    Using the standards of the American Welding Society and the American Society of Mechanical Engineers, this welding instructional guidelines manual presents a course of study in accordance with the current practices in industry. Intended for use in welding programs now practiced within the Federal Prison System, the phases of the program are…

  13. pre-art guidelines

    African Journals Online (AJOL)

    Enrique

    2004-11-01

    Nov 1, 2004 ... As these guidelines address pre-ART issues, only conditions that occur at ... All HIV-infected adults who are immunosuppressed, i.e. ... therefore recommended that HIV-infected health care ... vaccine in severely immunosuppressed persons, i.e. those ... with residual insecticides, the use of larvicides, and.

  14. Curricular Guidelines for Endodontics.

    Science.gov (United States)

    Journal of Dental Education, 1981

    1981-01-01

    Guidelines developed by the Section on Endodontics of the American Association of Dental Schools for use by educational institutions as curriculum development aids are provided. Endodontics is that branch of dentistry dealing with diagnosis and treatment of oral conditions that arise as a result of pathoses of dental pulp. (MLW)

  15. Evidence-based guidelines

    DEFF Research Database (Denmark)

    Wattjes, Mike P; Rovira, Àlex; Miller, David

    2015-01-01

    . This use of MRI can help predict treatment response and assess the efficacy and safety of new therapies. In the second part of the MAGNIMS (Magnetic Resonance Imaging in MS) network's guidelines on the use of MRI in MS, we focus on the implementation of this technique in prognostic and monitoring tasks. We...

  16. Guidelines for Authors

    Indian Academy of Sciences (India)

    IAS Admin

    Please follow the instructions given below while preparing the manuscript. Articles which do not conform to the guidelines will not be considered. Authors are encouraged to submit their article in ASCII/MS Word/Latex version in a CD or by email to resonanc@ias.ernet.in. Title: Authors are requested to provide a) first title ...

  17. Formalization of Medical Guidelines

    Czech Academy of Sciences Publication Activity Database

    Peleška, Jan; Anger, Z.; Buchtela, David; Šebesta, K.; Tomečková, Marie; Veselý, Arnošt; Zvára, K.; Zvárová, Jana

    2005-01-01

    Roč. 1, - (2005), s. 133-141 ISSN 1801-5603 R&D Projects: GA AV ČR 1ET200300413 Institutional research plan: CEZ:AV0Z10300504 Keywords : GLIF model * formalization of guidelines * prevention of cardiovascular diseases Subject RIV: IN - Informatics, Computer Science

  18. Record Keeping Guidelines

    Science.gov (United States)

    American Psychologist, 2007

    2007-01-01

    These guidelines are designed to educate psychologists and provide a framework for making decisions regarding professional record keeping. State and federal laws, as well as the American Psychological Association's "Ethical Principles of Psychologists and Code of Conduct," generally require maintenance of appropriate records of psychological…

  19. GRADE Equity Guidelines 3

    DEFF Research Database (Denmark)

    Welch, Vivian A; Akl, Elie A; Pottie, Kevin

    2017-01-01

    OBJECTIVE: The aim of this paper is to describe a conceptual framework for how to consider health equity in the GRADE (Grading Recommendations Assessment and Development Evidence) guideline development process. STUDY DESIGN AND SETTING: Consensus-based guidance developed by the GRADE working grou...

  20. Field Campaign Guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Voyles, J. W. [DOE ARM Climate Research Facility, Washington, DC (United States); Chapman, L. A. [DOE ARM Climate Research Facility, Washington, DC (United States)

    2015-12-01

    This document establishes a common set of guidelines for the Atmospheric Radiation Measurement (ARM) Climate Research Facility for planning, executing, and closing out field campaigns. The steps that guide individual field campaigns are described in the Field Campaign Tracking System and are specifically tailored to meet the scope of each field campaign.

  1. Curricular Guidelines for Neuroanatomy.

    Science.gov (United States)

    Journal of Dental Education, 1981

    1981-01-01

    Presented are the curricular guidelines for Neuroanatomy developed by the Section on Anatomical Sciences of the American Association of Dental Schools for use by individual educational institutions as curriculum development aids. Included are recommendations for primary educational goals, prerequisites, scope, content, behavioral objectives,…

  2. Space Guidelines for Libraries.

    Science.gov (United States)

    Wisconsin Coordinating Committee for Higher Education, Madison.

    The following guidelines are recommended: stack space--for each 10 volumes, one square foot of space; reading room--25 square feet per station x 20% of the total undergraduate population; carrel space--25% of the graduate enrollment x 45 square feet; office and auxilliary space--135 square feet x full time equivalent staff. (NI)

  3. Guidelines on testicular cancer

    NARCIS (Netherlands)

    Albers, Peter; Albrecht, Walter; Algaba, Ferran; Bokemeyer, Carsten; Cohn-Cedermark, Gabriella; Horwich, Alan; Klepp, Olbjoern; Laguna, M. Pilar; Pizzocaro, Giorgio

    2005-01-01

    To up-date the 2001 version of the EAU testicular cancer guidelines. A non-structured literature review until January 2005 using the MEDLINE database has been performed. Literature has been classified according to evidence-based medicine levels. Testicular cancer is a highly curable disease.

  4. Guidelines for Urban Labs

    DEFF Research Database (Denmark)

    Scholl, Christian; Agger Eriksen, Mette; Baerten, Nik

    2017-01-01

    urban lab initiatives from five different European cities: Antwerp (B), Graz and Leoben (A), Maastricht (NL) and Malmö (S). We do not pretend that these guidelines touch upon all possible challenges an urban lab may be confronted with, but we have incorporated all those we encountered in our...

  5. European Patient Summary Guideline: Focus on Greece.

    Science.gov (United States)

    Berler, Alexander; Tagaris, Anastassios; Chronaki, Catherine

    2016-01-01

    The European Patient Summary (PS) guideline specifies a minimal dataset of essential and important information for unplanned or emergency care initially defined in the epSOS project with aim to improve patients' safety and quality of Care. The eHealth Network of European Union (EU) Member State (MS) representatives established under Article 14 of the EU directive 2011/24 on patient rights to cross-border healthcare adopted PS guideline in November 2013 and since then the guideline has been part of MS strategic eHealth implementation plans, standardization efforts, and concrete regional, national, European and international projects. This paper reviews implementation efforts for the implementation of an operational patient summary service in Greece drawing on challenges and lessons learned for sustainable standards-based large scale eHealth deployment in Europe and abroad, as well as the reuse of best practices from international standards and integration profiles.

  6. Inspector qualification guidelines

    International Nuclear Information System (INIS)

    Batty, A.C.; Van Binnebeek, J.J.; Ericsson, P.O.; Fisher, J.C.; Geiger, P.; Grandame, M.; Grimes, B.K.; Joode, A. de; Kaufer, B.; Kinoshita, M.; Klonk, H.; Koizumi, H.; Maeda, N.; Maqua, M.; Perez del Moral, C.; Roselli, F.; Warren, T.; Zimmerman, R.

    1994-07-01

    The OECD Nuclear Energy Agency Committee on Nuclear Regulatory Activities (CNRA) has a Working Group on Inspection Practices (WGIP). The WGIP provides a forum for the exchange of Information and experience on the safety Inspection practices of regulatory authorities In the CNRA member countries. A consistent qualification process and well defined level of training for all Inspectors who participate In the safety Inspections are needed to provide consistent Inspections and reliable Inspection results. The WGIP organized in 1992 a workshop on the conduct of inspections, inspector qualification and training, and shutdown inspections at the Technical Training Center of the US NRC in Chattanooga, Tennessee. In the connection of workshop the WGIP identified a need to develop guidance for inspector qualification which could be used as a model by those who are developing their qualification practices. The inspector qualification journals of US NRC provided a good basis for the work. The following inspector qualification guideline has been developed for guidance of qualification of a new inspector recruited to the regulatory body. This guideline has been developed for helping the supervisors and training officers to give the initial training and familiarization to the duties of a new inspector in a controlled manner. US NRC inspector qualification journals have been used to define the areas of attention. This guideline provides large flexibility for application in different type organizations. Large organizations can develop separate qualification journals for each inspector positions. Small regulatory bodies can develop individual training programmes by defining the necessary training topics on case by case basis. E.g. the guideline can be used to define the qualifications of contracted inspectors used in some countries. The appropriate part would apply. Annex 1 gives two examples how this guideline could be applied

  7. Inspector qualification guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Batty, A. C.; Van Binnebeek, J. J.; Ericsson, P. O.; Fisher, J. C.; Geiger, P.; Grandame, M.; Grimes, B. K.; Joode, A. de; Kaufer, B.; Kinoshita, M.; Klonk, H.; Koizumi, H.; Maeda, N.; Maqua, M.; Perez del Moral, C.; Roselli, F.; Warren, T.; Zimmerman, R.

    1994-07-15

    The OECD Nuclear Energy Agency Committee on Nuclear Regulatory Activities (CNRA) has a Working Group on Inspection Practices (WGIP). The WGIP provides a forum for the exchange of Information and experience on the safety Inspection practices of regulatory authorities In the CNRA member countries. A consistent qualification process and well defined level of training for all Inspectors who participate In the safety Inspections are needed to provide consistent Inspections and reliable Inspection results. The WGIP organized in 1992 a workshop on the conduct of inspections, inspector qualification and training, and shutdown inspections at the Technical Training Center of the US NRC in Chattanooga, Tennessee. In the connection of workshop the WGIP identified a need to develop guidance for inspector qualification which could be used as a model by those who are developing their qualification practices. The inspector qualification journals of US NRC provided a good basis for the work. The following inspector qualification guideline has been developed for guidance of qualification of a new inspector recruited to the regulatory body. This guideline has been developed for helping the supervisors and training officers to give the initial training and familiarization to the duties of a new inspector in a controlled manner. US NRC inspector qualification journals have been used to define the areas of attention. This guideline provides large flexibility for application in different type organizations. Large organizations can develop separate qualification journals for each inspector positions. Small regulatory bodies can develop individual training programmes by defining the necessary training topics on case by case basis. E.g. the guideline can be used to define the qualifications of contracted inspectors used in some countries. The appropriate part would apply. Annex 1 gives two examples how this guideline could be applied.

  8. Environmental audit guidelines for pipelines

    International Nuclear Information System (INIS)

    1991-01-01

    Environmental auditing is a form of management control which provides an objective basis by which a company can measure the degree of compliance with environmental regulations. Other benefits of this type of auditing include improved environmental management, furthering communication on environmental issues of concern within the company, and provision of documentation on environmental diligence. A series of environmental audit guidelines for pipelines is presented in the form of lists of questions to be asked during an environmental audit followed by recommended actions in response to those questions. The questions are organized into seven main categories: environmental management and planning; operating procedures; spill prevention; management of wastes and hazardous materials; environmental monitoring; construction of pipelines; and pipeline abandonment, decommissioning and site reclamation

  9. Radioactive waste shredding: Preliminary evaluation

    International Nuclear Information System (INIS)

    Soelberg, N.R.; Reimann, G.A.

    1994-07-01

    The critical constraints for sizing solid radioactive and mixed wastes for subsequent thermal treatment were identified via a literature review and a survey of shredding equipment vendors. The types and amounts of DOE radioactive wastes that will require treatment to reduce the waste volume, destroy hazardous organics, or immobilize radionuclides and/or hazardous metals were considered. The preliminary steps of waste receipt, inspection, and separation were included because many potential waste treatment technologies have limits on feedstream chemical content, physical composition, and particle size. Most treatment processes and shredding operations require at least some degree of feed material characterization. Preliminary cost estimates show that pretreatment costs per unit of waste can be high and can vary significantly, depending on the processing rate and desired output particle size

  10. Computerization of guidelines: towards a "guideline markup language".

    Science.gov (United States)

    Dart, T; Xu, Y; Chatellier, G; Degoulet, P

    2001-01-01

    Medical decision making is one of the most difficult daily tasks for physicians. Guidelines have been designed to reduce variance between physicians in daily practice, to improve patient outcomes and to control costs. In fact, few physicians use guidelines in daily practice. A way to ease the use of guidelines is to implement computerised guidelines (computer reminders). We present in this paper a method of computerising guidelines. Our objectives were: 1) to propose a generic model that can be instantiated for any specific guidelines; 2) to use eXtensible Markup Language (XML) as a guideline representation language to instantiate the generic model for a specific guideline. Our model is an object representation of a clinical algorithm, it has been validated by running two different guidelines issued by a French official Agency. In spite of some limitations, we found that this model is expressive enough to represent complex guidelines devoted to diabetes and hypertension management. We conclude that XML can be used as a description format to structure guidelines and as an interface between paper-based guidelines and computer applications.

  11. Guidelines for Better Heart Health

    Science.gov (United States)

    Skip Navigation Bar Home Current Issue Past Issues Guidelines for Better Heart Health Past Issues / Winter 2007 ... women either had or did not have CVD. Guidelines at a Glance: Prevention should be tailored to ...

  12. 2012 Guidelines for Water Reuse

    Science.gov (United States)

    This manual is a revision of the "2004 Water Reuse Guidelines." This document is a summary of reuse guidelines, with supporting information, for the benefit of utilities of utilities and regulatory agencies, particularly EPA.

  13. Paralympic emblem guidelines: London 2012

    OpenAIRE

    2015-01-01

    The purpose of these guidelines is to preserve and enhance the value of the Emblem for the benefit of all authorised users. These guidelines apply to LOCOG and IPC creative, marketing and communications personnel, agencies and consultants only.

  14. Evaluation of TCOM/HBOT practice guideline for the treatment of foot burns occurring in diabetic patients.

    Science.gov (United States)

    Jones, Larry M; Rubadue, Christopher; Brown, Nicole V; Khandelwal, Sorabh; Coffey, Rebecca A

    2015-05-01

    A multidisciplinary team developed an evidence-based guideline for the management of foot burns occurring in diabetic patients that included transcutaneous oxygen measurements (TCOM) and application of hyperbaric oxygen therapy (HBOT) to selected patients. This report represents an evaluation of preliminary TCOM/HBOT data. This is a retrospective review of patients with diabetes mellitus (DM) who were admitted to a single American Burn Association (ABA) verified burn center for the treatment of foot burns. Patients were treated via the guideline if they were over the age of 16, admitted for the initial care of burns involving the feet between 4/01/2012 and 7/22/2013, and had a known or new diagnosis of DM. Eighteen patients were treated according to the guideline, 14 men and 4 women. Average age was 54 years+14.78. Average BMI was 30.63+6.34. Median burn size was 0.88% TBSA (median partial thickness of 1% and median full thickness of 0.5%). The average HbA1c was 9.08+2.42. Seven patients received pre-operative HBOT, two received post-operative HBOT and three patients healed their wounds with HBOT alone. Average hospital length of stay was 13.39 days+9.94 and was significantly longer for the group receiving HBOT. Admission HbA1c was not a predictor of the need for HBOT. While TCOM/HBOT therapy has not been widely applied to the management of diabetic foot burns, the use of an evidence-based guideline incorporating TCOM/HBOT can provide a systematic way to evaluate the patients' microcirculation and ability to heal burns of the foot. The incorporation of TCOM determination and application of HBOT in selected patients with DM and burns of the feet warrant continued study. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.

  15. Guidelines for emergency laparoscopy

    Directory of Open Access Journals (Sweden)

    Sauerland Stefan

    2006-10-01

    Full Text Available Abstract Acute abdominal pain is a leading symptom in many surgical emergency patients. Laparoscopy allows for accurate diagnosis and immediate therapy of many intraabdominal pathologies. The guidelines of the EAES (European Association for Endoscopic Surgery provides scientifically founded recommendations about the role of laparoscopy in the different situations. Generally, laparoscopy is well suited for the therapy of the majority of diseases that cause acute abdominal pain.

  16. Severe accident management guidelines

    International Nuclear Information System (INIS)

    Uhle, Jennifer

    2014-01-01

    The events at Fukushima Daiichi have highlighted the importance of Severe Accident Management Guidelines (SAMGs). As the world has learned from the catastrophe and countries are considering changes to their nuclear regulatory programs, the content of SAMGs and their regulatory control are being evaluated. This presentation highlights several factors that are being addressed in the United States as rulemaking is underway pertaining to SAMGs. The question of how to be prepared for the unexpected is discussed with specific insights gleaned from Fukushima. (author)

  17. Guidelines on oncologic imaging

    International Nuclear Information System (INIS)

    1989-01-01

    The present issue of European Journal of Radiology is devoted to guidelines on oncologic imaging. 9 experts on imaging in suspected or evident oncologic disease have compiled a broad survey on strategies as well as techniques on oncologic imaging. The group gives advice for detecting tumours at specific tumour sites and use modern literature to emphasize their recommendations. All recommendations are short, comprehensive and authoritative. (orig./MG)

  18. Guidelines for Urban Labs

    DEFF Research Database (Denmark)

    Scholl, Christian; Agger Eriksen, Mette; Baerten, Nik

    2017-01-01

    These guidelines are intended for team members and managers of urban labs and, more generally, for civil servants and facilitators in cities working with experimental processes to tackle complex challenges. They aim to support the everyday practice of collaboratively experimenting and learning ho...... the result is inspiring and instructive for all those who want to wrap their minds around experimental co-creative approaches to urban governance and city development....

  19. 78 FR 57319 - Children's Online Privacy Protection Rule Safe Harbor Proposed Self-Regulatory Guidelines...

    Science.gov (United States)

    2013-09-18

    ...-AB20 Children's Online Privacy Protection Rule Safe Harbor Proposed Self-Regulatory Guidelines; kidSAFE... proposed self-regulatory guidelines submitted by the kidSAFE Seal Program (``kidSAFE''), owned and operated... enabling industry groups or others to submit to the Commission for approval self-regulatory guidelines that...

  20. Guideline Implementation: Hand Hygiene.

    Science.gov (United States)

    Goldberg, Judith L

    2017-02-01

    Performing proper hand hygiene and surgical hand antisepsis is essential to reducing the rates of health care-associated infections, including surgical site infections. The updated AORN "Guideline for hand hygiene" provides guidance on hand hygiene and surgical hand antisepsis, the wearing of fingernail polish and artificial nails, proper skin care to prevent dermatitis, the wearing of jewelry, hand hygiene product selection, and quality assurance and performance improvement considerations. This article focuses on key points of the guideline to help perioperative personnel make informed decisions about hand hygiene and surgical hand antisepsis. The key points address the necessity of keeping fingernails and skin healthy, not wearing jewelry on the hands or wrists in the perioperative area, properly performing hand hygiene and surgical hand antisepsis, and involving patients and visitors in hand hygiene initiatives. Perioperative RNs should review the complete guideline for additional information and for guidance when writing and updating policies and procedures. Copyright © 2017 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  1. Cancer screening guidelines.

    Science.gov (United States)

    Zoorob, R; Anderson, R; Cefalu, C; Sidani, M

    2001-03-15

    Numerous medical organizations have developed cancer screening guidelines. Faced with the broad, and sometimes conflicting, range of recommendations for cancer screening, family physicians must determine the most reasonable and up-to-date method of screening. Major medical organizations have generally achieved consensus on screening guidelines for breast, cervical and colorectal cancer. For breast cancer screening in women ages 50 to 70, clinical breast examination and mammography are generally recommended every one or two years, depending on the medical organization. For cervical cancer screening, most organizations recommend a Papanicolaou test and pelvic examination at least every three years in patients between 20 and 65 years of age. Annual fecal occult blood testing along with flexible sigmoidoscopy at five-year to 10-year intervals is the standard recommendation for colorectal cancer screening in patients older than 50 years. Screening for prostate cancer remains a matter of debate. Some organizations recommend digital rectal examination and a serum prostate-specific antigen test for men older than 50 years, while others do not. In the absence of compelling evidence to indicate a high risk of endometrial cancer, lung cancer, oral cancer and ovarian cancer, almost no medical organizations have developed cancer screening guidelines for these types of cancer.

  2. Advanced human-system interface design review guidelines

    International Nuclear Information System (INIS)

    O'Hara, J.M.

    1990-01-01

    Advanced, computer-based, human-system interface designs are emerging in nuclear power plant (NPP) control rooms. These developments may have significant implications for plant safety in that they will greatly affect the ways in which operators interact with systems. At present, however, the only guidance available to the US Nuclear Regulatory Commission (NRC) for the review of control room-operator interfaces, NUREG-0700, was written prior to these technological changes and is thus not designed to address them. The objective of the project reported in this paper is to develop an Advanced Control Room Design Review Guideline for use in performing human factors reviews of advanced operator interfaces. This guideline will be implemented, in part, as a portable, computer-based, interactive document for field use. The paper describes the overall guideline development methodology, the present status of the document, and the plans for further guideline testing and development. 21 refs., 3 figs

  3. Design principle of TVO's final repository and preliminary adaptation to site specific conditions

    International Nuclear Information System (INIS)

    Salo, J-P.; Reikkola, R.

    1995-01-01

    Teollisuuden Voima Oy (TVO) is responsible for the management of spent fuel produced by the Olkiluoto power plant. TVO's current programme of spent fuel management is based on the guidelines and time schedule set by the Finnish Government. TVO has studied a final disposal concept in which the spent fuel bundles are encapsulated in copper canisters and emplaced in Finnish bedrock. According to the plan the final repository for spent fuel will be in operation by 2020. TVO's updated technical plans for the disposal of spent fuel together with a performance analysis (TVO-92) were submitted to the authorities in 1992. The paper describes the design principle of TVO's final repository and preliminary adaptation of the repository to site specific conditions. (author). 10 refs., 5 figs

  4. Workshop presentation: research guidelines for Construction Management

    OpenAIRE

    Marco Alvise Bragadin

    2013-01-01

    Nowadays the European economic system challenges the construction sector to take part to industrial recovery of western countries. In co-operation with the Construction Production research group of the Tampere University of of research about construction management tools and methods were detected. Research guidelines: 1) Construction management: tools and methods to manage construction projects 2) environmental impact of construction projects 3) construction management and safety 4) project p...

  5. Workshop presentation: research guidelines for Construction Management

    Directory of Open Access Journals (Sweden)

    Marco Alvise Bragadin

    2013-10-01

    Full Text Available Nowadays the European economic system challenges the construction sector to take part to industrial recovery of western countries. In co-operation with the Construction Production research group of the Tampere University of of research about construction management tools and methods were detected. Research guidelines: 1 Construction management: tools and methods to manage construction projects 2 environmental impact of construction projects 3 construction management and safety 4 project procurement 5 construction management for major public works & complex projects

  6. [Quality indicators for National Disease Management Guidelines using the example of the National Disease Management Guideline for "Chronic Heart Failure"].

    Science.gov (United States)

    Nothacker, Monika Judith; Langer, Thomas; Weinbrenner, Susanne

    2011-01-01

    Together with an expert committee a structured approach to determining quality indicators for National Disease Management Guidelines has been developed. The key steps of this approach include: introducing guideline authors to the methodology at an early stage of the process of guideline development, pre-selecting recommendations of the guideline which are potentially measurable by means of quality indicators, assessing the potentially measurable quality indicators in written form using five criteria (including their importance for the health care system and clarity of definitions) and approving them in a formal consensus process. For lack of a database these quality indicators must be regarded as preliminary. For the National Disease Management Guideline "Chronic Heart Failure" nine rate-based indicators have been chosen. The indicators correspond to important strong recommendations (grade of recommendation: A) from the fields of diagnosis (two), general therapeutic strategy (two), specific treatment (three), clinical monitoring (one) and co-ordination of care (one). In a second step, the quality indicators have to be validated within a pilot project. The determination and assessment of the potential quality indicators have revealed room for improvement of guideline development. In particular, there is a need for more health care data and for specification of recommendations.

  7. Network operating system

    Science.gov (United States)

    1985-01-01

    Long-term and short-term objectives for the development of a network operating system for the Space Station are stated. The short-term objective is to develop a prototype network operating system for a 100 megabit/second fiber optic data bus. The long-term objective is to establish guidelines for writing a detailed specification for a Space Station network operating system. Major milestones are noted. Information is given in outline form.

  8. Nurses' experiences of guideline implementation

    DEFF Research Database (Denmark)

    Alanen, Seija; Välimäki, Marita; Kaila, Minna

    2009-01-01

    AIMS: The aim of the study was to address the following questions: What kind of experiences do primary care nurses have of guideline implementation? What do nurses think are the most important factors affecting the adoption of guidelines? BACKGROUND: The implementation of clinical guidelines seems...... to be dependent on multiple context-specific factors. This study sets out to explore the experiences of primary care nurses concerning guideline implementation. DESIGN: Qualitative interview. METHODS: Data were generated by four focus group interviews involving nurses working in out-patient services in primary...... to nurses, (iii) factors related to the anticipated consequences and (iv) factors related to the patient group. Nurses' awareness and acceptance of guidelines and the anticipated positive consequences facilitate the implementation of guidelines. Organisational support, especially the adapting of guidelines...

  9. A review of clinical guidelines.

    LENUS (Irish Health Repository)

    Andrews, E J

    2012-02-03

    BACKGROUND: Clinical guidelines are increasingly used in patient management but few clinicians are familiar with their origin or appropriate application. METHODS: A Medline search using the terms \\'clinical guidelines\\' and \\'practice guidelines\\' was conducted. Additional references were sourced by manual searching from the bibliographies of articles located. RESULTS AND CONCLUSION: Clinical guidelines originated in the USA in the early 1980s, initially as a cost containment exercise. Significant improvements in the process and outcomes of care have been demonstrated following their introduction, although the extent of improvement varies considerably. The principles for the development of guidelines are well established but many published guidelines fall short of these basic quality criteria. Guidelines are only one aspect of improving quality and should be used within a wider framework of promoting clinical effectiveness. Understanding their limitations as well as their potential benefits should enable clinicians to have a clearer view of their place in everyday practice.

  10. Adaptive strategies of remote systems operators exposed to perturbed camera-viewing conditions

    Science.gov (United States)

    Stuart, Mark A.; Manahan, Meera K.; Bierschwale, John M.; Sampaio, Carlos E.; Legendre, A. J.

    1991-01-01

    This report describes a preliminary investigation of the use of perturbed visual feedback during the performance of simulated space-based remote manipulation tasks. The primary objective of this NASA evaluation was to determine to what extent operators exhibit adaptive strategies which allow them to perform these specific types of remote manipulation tasks more efficiently while exposed to perturbed visual feedback. A secondary objective of this evaluation was to establish a set of preliminary guidelines for enhancing remote manipulation performance and reducing the adverse effects. These objectives were accomplished by studying the remote manipulator performance of test subjects exposed to various perturbed camera-viewing conditions while performing a simulated space-based remote manipulation task. Statistical analysis of performance and subjective data revealed that remote manipulation performance was adversely affected by the use of perturbed visual feedback and performance tended to improve with successive trials in most perturbed viewing conditions.

  11. Vitamin D supplementation guidelines.

    Science.gov (United States)

    Pludowski, Pawel; Holick, Michael F; Grant, William B; Konstantynowicz, Jerzy; Mascarenhas, Mario R; Haq, Afrozul; Povoroznyuk, Vladyslav; Balatska, Nataliya; Barbosa, Ana Paula; Karonova, Tatiana; Rudenka, Ema; Misiorowski, Waldemar; Zakharova, Irina; Rudenka, Alena; Łukaszkiewicz, Jacek; Marcinowska-Suchowierska, Ewa; Łaszcz, Natalia; Abramowicz, Pawel; Bhattoa, Harjit P; Wimalawansa, Sunil J

    2018-01-01

    Research carried out during the past two-decades extended the understanding of actions of vitamin D, from regulating calcium and phosphate absorption and bone metabolism to many pleiotropic actions in organs and tissues in the body. Most observational and ecological studies report association of higher serum 25-hydroxyvitamin D [25(OH)D] concentrations with improved outcomes for several chronic, communicable and non-communicable diseases. Consequently, numerous agencies and scientific organizations have developed recommendations for vitamin D supplementation and guidance on optimal serum 25(OH)D concentrations. The bone-centric guidelines recommend a target 25(OH)D concentration of 20ng/mL (50nmol/L), and age-dependent daily vitamin D doses of 400-800IU. The guidelines focused on pleiotropic effects of vitamin D recommend a target 25(OH)D concentration of 30ng/mL (75nmol/L), and age-, body weight-, disease-status, and ethnicity dependent vitamin D doses ranging between 400 and 2000IU/day. The wise and balanced choice of the recommendations to follow depends on one's individual health outcome concerns, age, body weight, latitude of residence, dietary and cultural habits, making the regional or nationwide guidelines more applicable in clinical practice. While natural sources of vitamin D can raise 25(OH)D concentrations, relative to dietary preferences and latitude of residence, in the context of general population, these sources are regarded ineffective to maintain the year-round 25(OH)D concentrations in the range of 30-50ng/mL (75-125nmol/L). Vitamin D self-administration related adverse effects, such as hypercalcemia and hypercalciuria are rare, and usually result from taking extremely high doses of vitamin D for a prolonged time. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Practice guidelines. Cookbook medicine.

    Science.gov (United States)

    Harding, J

    1994-08-01

    A large measure of the confusion and doubt currently being sowed in the ongoing debate over the advisability and effectiveness of practice guidelines is a matter of terminology. In deference to the wishes and fears of physicians, the term "requirements" is not used. But requirements they are. Their quality and the degree to which they are useful will depend on their level of detail and the degree to which they are based on positive outcomes. Regardless, attorneys and others will always view and use them as requirements.

  13. CAD-guidelines

    International Nuclear Information System (INIS)

    Schlechtendahl, E.G.; Lang-Lendorff, G.

    1982-10-01

    The CAD-guidelines (CAD = Computer Aided Design) contain rules for programming, structuring and documentation of programs. The standard deals with the structure of CAD-programs, their components, the programming-methods, the language etc. It describes what documents and references are necessary for a CAD-program. In order to gain a broad application of CAD criteria like portability and completeness of the documentation for an effective maintenance are as important as a transparent way of producing CAD-software. (orig.) [de

  14. 40 CFR 417.162 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Detergents Subcategory § 417.162 Effluent limitations guidelines... available (BPT): (a) For normal liquid detergent operations the following values pertain: Effluent...

  15. Deriving cleanup guidelines for radionuclides at Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Meinhold, A.F.; Morris, S.C.; Dionne, B.; Moskowitz, P.D.

    1997-01-01

    Past activities at Brookhaven National Laboratory (BNL) resulted in soil and groundwater contamination. As a result, BNL was designated a Superfund site under the Comprehensive Environmental Response Compensation and Liability Act (CERCLA). BNL`s Office of Environmental Restoration (OER) is overseeing environmental restoration activities at the Laboratory. With the exception of radium, there are no regulations or guidelines to establish cleanup guidelines for radionuclides in soils at BNL. BNL must derive radionuclide soil cleanup guidelines for a number of Operable Units (OUs) and Areas of Concern (AOCs). These guidelines are required by DOE under a proposed regulation for radiation protection of public health and the environment as well as to satisfy the requirements of CERCLA. The objective of this report is to propose a standard approach to deriving risk-based cleanup guidelines for radionuclides in soil at BNL. Implementation of the approach is briefly discussed.

  16. Deriving cleanup guidelines for radionuclides at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Meinhold, A.F.; Morris, S.C.; Dionne, B.; Moskowitz, P.D.

    1997-01-01

    Past activities at Brookhaven National Laboratory (BNL) resulted in soil and groundwater contamination. As a result, BNL was designated a Superfund site under the Comprehensive Environmental Response Compensation and Liability Act (CERCLA). BNL's Office of Environmental Restoration (OER) is overseeing environmental restoration activities at the Laboratory. With the exception of radium, there are no regulations or guidelines to establish cleanup guidelines for radionuclides in soils at BNL. BNL must derive radionuclide soil cleanup guidelines for a number of Operable Units (OUs) and Areas of Concern (AOCs). These guidelines are required by DOE under a proposed regulation for radiation protection of public health and the environment as well as to satisfy the requirements of CERCLA. The objective of this report is to propose a standard approach to deriving risk-based cleanup guidelines for radionuclides in soil at BNL. Implementation of the approach is briefly discussed

  17. Preliminary tests of the electrostatic plasma accelerator

    Science.gov (United States)

    Aston, G.; Acker, T.

    1990-01-01

    This report describes the results of a program to verify an electrostatic plasma acceleration concept and to identify those parameters most important in optimizing an Electrostatic Plasma Accelerator (EPA) thruster based upon this thrust mechanism. Preliminary performance measurements of thrust, specific impulse and efficiency were obtained using a unique plasma exhaust momentum probe. Reliable EPA thruster operation was achieved using one power supply.

  18. Computerizing clinical practice guidelines

    DEFF Research Database (Denmark)

    Lyng, Karen Marie

    It is well described that hospitals have problems with sustaining high quality of care and expedient introduction of new medical knowledge. Clinical practice guidelines (CPGs) have been promoted as a remedy to deal with these problems. It is, however, also well described that application and comp......It is well described that hospitals have problems with sustaining high quality of care and expedient introduction of new medical knowledge. Clinical practice guidelines (CPGs) have been promoted as a remedy to deal with these problems. It is, however, also well described that application...... is comprised by fieldwork in three oncology departments and a case study of advanced life support. Although close to all patients within oncology are treated according to a CPG, I found limited application of physical CPGs and web-based CPG portals. However, I found comprehensive application of activity...... of the business strategic aims, and 3) analysis and formalization of CPGs. This will imply orchestration of design teams with competencies from a wide array of disciplines such as health practice, business management, knowledge management and information systems....

  19. [Anemia: guidelines comparison].

    Science.gov (United States)

    Del Vecchio, Lucia

    2009-01-01

    The development of recombinant human erythropoietin and its introduction into the market in the late 1980s has significantly improved the quality of life of patients with chronic kidney disease (CKD) and reduced the need for blood transfusions. Starting from a cautious target, a progressive increase in the recommended hemoglobin levels has been observed over the years, in parallel with an increase in the obtained levels. This trend has gone together with the publication of findings of observational studies showing a relationship between the increase in hemoglobin levels and a reduction in the mortality risk, with the conduction of clinical trials testing the effects of complete anemia correction, and with the compilation of guidelines on anemia control in CKD patients by scientific societies and organizations. In the last two years, evidence of a possible increase in the mortality risk in those patients who were randomized to high hemoglobin levels has resulted in a decrease in the upper limit of the recommended Hb target to be obtained with erythropoietin stimulating agents (ESA), and consequently in a narrowing of the target range. Comparison of guidelines on anemia control in CKD patients is an interesting starting point to discuss single recommendations, strengthen their importance, or suggest new topics of research to fill up important gaps in knowledge.

  20. Postdoctoral program guidelines.

    Energy Technology Data Exchange (ETDEWEB)

    Teich-McGoldrick, Stephanie; Miller, Andrew W.; Sava, Dorina Florentina; Liu, Yanli; Ferreira, Summer Rhodes; Biedermann, Laura Butler; Cruz-Campa, Jose Luis; Hall, Lisa Michelle; Liu, Xiaohua H.; Ekoto, Isaac

    2012-04-01

    We, the Postdoc Professional Development Program (PD2P) leadership team, wrote these postdoc guidelines to be a starting point for communication between new postdocs, their staff mentors, and their managers. These guidelines detail expectations and responsibilities of the three parties, as well as list relevant contacts. The purpose of the Postdoc Program is to bring in talented, creative people who enrich Sandia's environment by performing innovative R&D, as well as by stimulating intellectual curiosity and learning. Postdocs are temporary employees who come to Sandia for career development and advancement reasons. In general, the postdoc term is 1 year, renewable up to five times for a total of six years. However, center practices may vary; check with your manager. At term, a postdoc may apply for a staff position at Sandia or choose to move to university, industry or another lab. It is our vision that those who leave become long-term collaborators and advocates whose relationships with Sandia have a positive effect upon our national constituency.

  1. Soil and groundwater remediation guidelines for methanol

    International Nuclear Information System (INIS)

    2010-12-01

    Methanol is used by oil and gas operators to inhibit hydrate formation in the recovery of heavy oils, in natural gas production and transport, as well as in various other production applications. Emissions from methanol primary occur from miscellaneous solvent usage, methanol production, end-product manufacturing, and storage and handling losses. This document provided soil and groundwater remediation guidelines for methanol releases into the environment. The guidelines were consistent with the Alberta Environment tier 1 soil and groundwater framework. The chemical and physical properties of methanol were reviewed. The environmental fate and behavior of methanol releases was discussed, and the behaviour and effects of methanol in terrestrial and aquatic biota were evaluated. The toxicity of methanol and its effects in humans and mammalian species were reviewed. Soil quality and ground water quality guidelines were presented. Surface water and soil guideline calculation methods were provided, and ecological exposure and ground water pathways were discussed. Management limits for methanol concentrations were also provided. 162 refs., 18 tabs., 4 figs.

  2. A preliminary framework for corporate real estate sustainable management

    Directory of Open Access Journals (Sweden)

    Fauzi Nurul Sahida

    2016-01-01

    Full Text Available The global warming issue has motivated corporations to go green in their business operations including transforming from conventional real estate to green features real estate. However green CRE is more complex to manage due to a building’s significant impact on environmental, social and economic aspects. Thus the need to have a best practice guide or framework as reference is crucial. Unfortunately, no best practice guidelines on CRE management have been found to be sufficient as much uncertainty still exists on the sustainable performance measurement components. This research aims to explore and then summarize the present sustainable CREM practices and components relating to sustainable performance measurement integrating a sustainable theory that balances environmental, economic and social impacts. These act as indicators to measure the outcomes of the practice in the form of a generic model on sustainability preliminary framework for CRESM. The objectives of this research include identifying corporate real estate sustainable management (CRESM practice and components of sustainable performance measurement. The research uses content analysis method to analyse data gathered from literature and previous studies. The findings will be demonstrated in the form of a framework model on CRESM that will include14 CREM strategies and 15 components derived from analysis.

  3. Additional guideline for the design of BWR reload patterns

    International Nuclear Information System (INIS)

    Burte, D.P.

    1990-01-01

    The problems of the high magnitude of the reactivity worths of control rods/notches and the thermal shocks to fuel due to control rod withdrawals are considered in this paper. These problems are shown to be mitigated if in addition to complying with the traditional guidelines for designing fuel bundles and reload patterns the proposed additional guideline (in the form of the condition that the shape of the K∞ distribution remains constant throughout the cycle) is also complied with. It is argued that application of the additional guideline for operating conditions ensures that the core can operate with a constant power profile throughout the cycle without control rod movement. Fixed (integral or stand-alone) burnable poisons are thought to be useful in this regard. Some comments on how this may be attempted are included. Additional advantages resulting from the additional guideline are discussed. (author)

  4. NOS CO-OPS Water Level Data, Preliminary, 6-Minute

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset has recent, preliminary (not quality-controlled), 6-minute, water level (tide) data from NOAA NOS Center for Operational Oceanographic Products and...

  5. NOS CO-OPS Water Level Data, Preliminary, 1-Minute

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset has recent, preliminary (not quality-controlled), 1-minute, water level (tide) data from NOAA NOS Center for Operational Oceanographic Products and...

  6. Guidelines to Career Development for Wastewater Treatment Plant Personnel.

    Science.gov (United States)

    Environmental Protection Agency, Washington, DC. Office of Education and Manpower Planning.

    The guidelines were written to promote job growth and improvement in the personnel who manage, operate, and maintain wastewater treatment plants. Trained operators and technicians are the key components in any water pollution control facility. The approach is to move from employment to training through specific modules for 21 standard job…

  7. Proposed DoD Guidelines for Implementation of a Web-Based Joint IETM Architecture (JIA) to Assure the Interoperability of DoD IETMs

    National Research Council Canada - National Science Library

    Jorgensen, Eric L

    1999-01-01

    This Paper presents preliminary guidelines intended to serve as input to a planned DoD Handbook for the Acquisition and Deployment of DoD IETMs with the specific purpose of assuring interoperability...

  8. Guidelines for control room design reviews

    International Nuclear Information System (INIS)

    1981-09-01

    The control room design review is part of a broad program being undertaken by the nuclear industry and the government to ensure consideration of human factors in nuclear power plant design and operation. The purpose of the control room design review described by these guidelines is to (1) review and evaluate the control room workspace, instrumentation, controls, and other equipment from a human factors engineering point of view that takes into account both system demands and operator capabilities; and (2) to identify, assess, and implement control room design modifications that correct inadequate or unsuitable items. The scope of the control room design review described by these guidelines covers the human engineering review of completed control rooms; i.e., operational control rooms or those at that stage of the licensing process where control room design and equipment selection are committed. These guidelines should also be of use during the design process for new control rooms. However, additional analyses to optimize the allocation of functions to man and machine, and further examination of advanced control system technology, are recommended for new control rooms. Guidelines and references for comprehensive system analyses designed to incorporate human factors considerations into the design and development of new control rooms are presented in Appendix B. Where possible, a generic approach to the control room design review process is encouraged; for example, when control room designs are replicated wholly or in part in two or more units. Even when designs are not replicated exactly, generic reviews which can be modified to account for specific differences in particular control rooms should be considered. Industry organizations and owners groups are encouraged to coordinate joint efforts and share data to develop generic approaches to the design review process. The control room design review should accomplish the following specific objectives. To determine

  9. Technical guideline technology according to the X-ray regulations

    International Nuclear Information System (INIS)

    2011-01-01

    The guideline covers the required technical knowledge concerning radiation protection and knowledge concerning for the operation of X-ray devices for technical purposes and stray radiation sources requiring licensing, and requirements for the qualification of officially authorized inspectors. The guidelines includes the following chapters: (1) introductory regulations; (2) Volume of the required technical knowledge; (3) Acquirement and certification of the technical knowledge; (4) Actualization of the technical knowledge; (5)Approval of courses and other training measures; (6) Combination of courses and training measures according to the guideline; (7) Requirements for qualification of officially authorized inspectors; (8) Interim regulations.

  10. Operant Variability: Procedures and Processes

    Science.gov (United States)

    Machado, Armando; Tonneau, Francois

    2012-01-01

    Barba's (2012) article deftly weaves three main themes in one argument about operant variability. From general theoretical considerations on operant behavior (Catania, 1973), Barba derives methodological guidelines about response differentiation and applies them to the study of operant variability. In the process, he uncovers unnoticed features of…

  11. Health physics appraisal guidelines for fusion/confinement devices

    International Nuclear Information System (INIS)

    Neeson, P.M.

    1987-01-01

    Several types of fusion/confinement devices have been developed for a variety of research applications. The health physics considerations for these devices can vary, depending on a number of parameters. This paper presents guidelines for health physics appraisal of such devices, which can be tailored to apply to specific systems. The guidelines can also be useful for establishing ongoing health physics programs for safe operation of the devices

  12. Fatores associados ao uso de diretrizes clínicas em operadoras de planos de saúde e prestadores de serviços hospitalares no campo da Saúde Suplementar no Brasil Factors associated with the use of clinical guidelines by health plan operators and their inpatient care providers

    Directory of Open Access Journals (Sweden)

    Margareth Crisóstomo Portela

    2008-10-01

    Full Text Available Este artigo objetiva identificar fatores associados ao uso de diretrizes clínicas, segundo percepção de dirigentes respondentes, em operadoras de planos de saúde e prestadores de serviços hospitalares no campo da saúde suplementar no Brasil. Utiliza dados de dois inquéritos de abrangência nacional: um envolvendo 90 operadoras selecionadas aleatoriamente de um universo de 1.573, voltado para a caracterização da implementação de diretrizes clínicas e outros instrumentos e práticas de gestão da clínica; e outro envolvendo 74 hospitais, selecionados de um universo de 3.817 prestadores de serviços hospitalares a planos de saúde, destinado a apreender os mecanismos de microrregulação das operadoras e suas possíveis repercussões sobre as práticas dos hospitais. Referiram o uso de diretrizes clínicas 32,3% das operadoras e 51,6% dos hospitais. Entre as primeiras, mostraram-se independentemente associados ao uso de diretrizes, localização geográfica, tipo e porte da operadora, enquanto que, entre os hospitais, porte, complexidade e uso de outras ferramentas da gestão da clínica. Os resultados evidenciam o quanto ainda é incipiente e insatisfatória a gestão, por operadoras e hospitais, sobre a qualidade dos cuidados à saúde providos aos pacientes.This paper is aimed at identifying factors related to the use of clinical guidelines by health plan operators and their inpatient care providers in the supplementary care sector in Brazil from the viewpoint of managers. The study is based on two national surveys: one involving 90 health plan operators randomly selected from a universe of 1573, oriented towards characterizing the implementation of clinical guidelines and other tools of clinical governance; and another involving 74 hospitals, selected from a universe of 3817 inpatient care providers, aimed at capturing micro-regulation mechanisms applied by health plan operators and their repercussions on hospital practices. Use of

  13. Olympic emblem guidelines: London 2012

    OpenAIRE

    2013-01-01

    These guidelines issued by the London Organising Committee of the Olympic Games and Paralympic Games Ltd (“LOCOG”) provide standards, requirements and guidelines for use of the London 2012 Olympic Games Emblem (the “Emblem”) by LOCOG and the International Olympic Committee (IOC) creative, marketing and communications personnel, agencies and consultants only who are authorised to use the London 2012 marks. The purpose of these guidelines is to preserve and enhance the value of the Emblem for t...

  14. Guidelines for Remote Handling Maintenance of ITER Neutral Beam Components

    International Nuclear Information System (INIS)

    Cordier, J.-J.; Hemsworth, R.; Bayetti, P.

    2006-01-01

    Remote handling maintenance of ITER components is one of the main challenges of the ITER project. This type of maintenance shall be operational for the nuclear phase of exploitation of ITER, and be considered at a very early stage since it significantly impacts on the components design, interfaces management and integration business. A large part of the R/H equipment will be procured by the EU partner, in particular the whole Neutral Beam Remote Handling (RH) equipment package. A great deal of work has already been done in this field during the EDA phase of ITER project, but improvements and alternative option that are now proposed by ITER lead to added RH and maintenance engineering studies. The Neutral Beam Heating -and- Current Drive system 1 is being revisited by the ITER project. The vertical maintenance scheme that is presently considered by ITER, may significantly impact on the reference design of the Neutral Beam (NB) system and associated components and lead to new design of the NB box itself. In addition, revision of both NB cell radiation level zoning and remote handling classification of the beam line injector will also significantly impact on components design and maintenance. Based on the experience gained on the vertical maintenance scheme, developed in detail for the ITER Neutral Beam Test Facility 2 to be built in Europe in a near future, guidelines for the revision of the design and preliminary feasibility study of the remote handling vertical maintenance scheme of beam line components are described in the paper. A maintenance option for the SINGAP3 accelerator is also presented. (author)

  15. SARIS Guidelines. 2014 Ed

    International Nuclear Information System (INIS)

    2014-01-01

    The IAEA fundamental safety principles provide the basis for IAEA safety standards and IAEA related programmes. IAEA safety standards reflect an international consensus on what constitutes a high level of safety for protecting people and the environment, and therefore represent what all regulators should achieve. These standards, in particular IAEA Safety Standards Series No. GSR Part 1, Governmental, Legal and Regulatory Framework for Safety, provide the basics for establishing, maintaining and continuously improving the governmental, legal and regulatory framework for safety. Additional IAEA requirements and guidance, such as the IAEA Safety Standards Series No. GSR Part 3 (Interim), Radiation Protection and Safety of Radiation Sources: International Basic Safety Standards, and IAEA Safety Standards Series No. GS-R-3, The Management System for Facilities and Activities, are also used to establish and develop the national infrastructure for safety and for establishing and implementing a management system. Assessment of the regulatory framework for safety with respect to the IAEA safety standards can be made either through an external review or through internal self-assessment. Self-assessment offers a mechanism by which an organization can assess its performance against established standards and models and thereby identify areas for improvement. The IAEA has developed a methodology and tool for Self-assessment of the Regulatory Infrastructure for Safety (SARIS), to assist States in undertaking self-assessment of their national safety framework in accordance with the requirements and recommendations of the IAEA safety standards, and to develop an action plan for improvement. The IAEA self-assessment methodology and the associated tools are fully compatible with the IAEA safety standards and are also used in the preparation for regulatory review missions, such as the Integrated Regulatory Review Service and advisory missions. These guidelines have been developed to

  16. Hydrothermal Liquefaction Treatment Preliminary Hazard Analysis Report

    Energy Technology Data Exchange (ETDEWEB)

    Lowry, Peter P.; Wagner, Katie A.

    2015-08-31

    A preliminary hazard assessment was completed during February 2015 to evaluate the conceptual design of the modular hydrothermal liquefaction treatment system. The hazard assessment was performed in 2 stages. An initial assessment utilizing Hazard Identification and Preliminary Hazards Analysis (PHA) techniques identified areas with significant or unique hazards (process safety-related hazards) that fall outside of the normal operating envelope of PNNL and warranted additional analysis. The subsequent assessment was based on a qualitative What-If analysis. This analysis was augmented, as necessary, by additional quantitative analysis for scenarios involving a release of hazardous material or energy with the potential for affecting the public.

  17. Preliminary I&C Design for LORELEI

    International Nuclear Information System (INIS)

    Korotkin, S.; Kaufman, Y.; Guttmann, E. B.; Levy, S.; Amidan, D.; Gdalyho, B.; Cahana, T.; Ellenbogen, A.; Arad, M.; Weiss, Y.; Sasson, A.; Ferry, L.; Bourrelly, F.; Cohen, Y.

    2014-01-01

    This document summarizes the preliminary I&C design for LORELEI experiment The preliminary design deals with considerations regarding appropriate safety and service instrumentation. The determined closed loop control rules for temperature and position will be implemented in the detailed design. The Computer Aided Operator Decisions System (CAODS) will be used for prediction of hot spot temperature and thickness of oxidation layer using Baker-Just correlation. The proposed hybrid simulation system comprising of both virtual and real hardware will be in-cooperated for LORELEI verification. It will perform both integration cold tests for a partial hardware loop and virtual tests for the final I&C design

  18. Guidelines for computer security in general practice.

    Science.gov (United States)

    Schattner, Peter; Pleteshner, Catherine; Bhend, Heinz; Brouns, Johan

    2007-01-01

    As general practice becomes increasingly computerised, data security becomes increasingly important for both patient health and the efficient operation of the practice. To develop guidelines for computer security in general practice based on a literature review, an analysis of available information on current practice and a series of key stakeholder interviews. While the guideline was produced in the context of Australian general practice, we have developed a template that is also relevant for other countries. Current data on computer security measures was sought from Australian divisions of general practice. Semi-structured interviews were conducted with general practitioners (GPs), the medical software industry, senior managers within government responsible for health IT (information technology) initiatives, technical IT experts, divisions of general practice and a member of a health information consumer group. The respondents were asked to assess both the likelihood and the consequences of potential risks in computer security being breached. The study suggested that the most important computer security issues in general practice were: the need for a nominated IT security coordinator; having written IT policies, including a practice disaster recovery plan; controlling access to different levels of electronic data; doing and testing backups; protecting against viruses and other malicious codes; installing firewalls; undertaking routine maintenance of hardware and software; and securing electronic communication, for example via encryption. This information led to the production of computer security guidelines, including a one-page summary checklist, which were subsequently distributed to all GPs in Australia. This paper maps out a process for developing computer security guidelines for general practice. The specific content will vary in different countries according to their levels of adoption of IT, and cultural, technical and other health service factors. Making

  19. Flexible guideline-based patient careflow systems.

    Science.gov (United States)

    Quaglini, S; Stefanelli, M; Lanzola, G; Caporusso, V; Panzarasa, S

    2001-04-01

    Workflow Management Systems integrate domain and organisational knowledge to support business processes. When applied to the medical environment, they can be termed "Careflow Management Systems", and may be used to manage care delivery by enhancing co-operation among healthcare professionals. This paper focuses on care delivery based on clinical practice guidelines. Healthcare organisations are very different from industrial or commercial companies: their main goal is not profit, but maintaining and improving the health of the public. Therefore, outcomes are difficult to measure. Firstly, physicians, while playing a variety of roles, are quite independent decision-makers; secondly, the object of the process, i.e. the patient, may be involved in choosing treatment options, and may be treated by different institutions. For these reasons, the standard functionality of typical Workflow Management Systems must be strongly enhanced in order to cope with healthcare delivery needs. A major issue is accounting for exceptions. In most non-clinical settings this is not a problem because processes are very well defined and can often be easily controlled by some higher authority. As explained above, this does not happen in healthcare organisations. Responsibilities are widely shared, and health care professionals may be non-compliant with guidelines for a variety of reasons. The paper presents a classification of possible exceptions, and shows how the sequence of tasks described by a guideline may be altered, at the implementation level, in order to meet actual user needs, while maintaining guideline intentions as much as possible. A terminology server is also exploited towards this end. This work illustrates a prototype of a Careflow Management System based on an international guideline for ischemic stroke treatment, developed by the American Heart Association.

  20. Health requirements for nuclear reactor operators

    International Nuclear Information System (INIS)

    1980-05-01

    The health prerequisites established for the qualification of nuclear reactor operators according to CNEN-NE-1.01 Guidelines Licensing of nuclear reactor operators, CNEN-12/79 Resolution, are described. (M.A.) [pt

  1. Engineering design guidelines for nuclear criticality safety

    International Nuclear Information System (INIS)

    Waltz, W.R.

    1988-08-01

    This document provides general engineering design guidelines specific to nuclear criticality safety for a facility where the potential for a criticality accident exists. The guide is applicable to the design of new SRP/SRL facilities and to major modifications Of existing facilities. The document is intended an: A guide for persons actively engaged in the design process. A resource document for persons charged with design review for adequacy relative to criticality safety. A resource document for facility operating personnel. The guide defines six basic criticality safety design objectives and provides information to assist in accomplishing each objective. The guide in intended to supplement the design requirements relating to criticality safety contained in applicable Department of Energy (DOE) documents. The scope of the guide is limited to engineering design guidelines associated with criticality safety and does not include other areas of the design process, such as: criticality safety analytical methods and modeling, nor requirements for control of the design process

  2. ITER physics design guidelines: 1989

    International Nuclear Information System (INIS)

    Uckan, N.A.

    1990-01-01

    The physics basis for ITER has been developed from an assessment of the results of the last twenty-five years of tokamak research and from detailed analysis of important physics issues specifically for the ITER design. This assessment has been carried out with direct participation of members of the experimental teams of each of the major tokamaks in the world fusion program through participation in ITER workshops, contributions to the ITER Physics R and D Program, and by direct contacts between the ITER team and the cognizant experimentalists. Extrapolations to the present data base, where needed, are made in the most cautious way consistent with engineering constraints and performance goals of the ITER. In cases where a working assumptions had to be introduced, which is insufficiently supported by the present data base, is explicitly stated. While a strong emphasis has been placed on the physics credibility of the design, the guidelines also take into account that ITER should be designed to be able to take advantage of potential improvements in tokamak physics that may occur before and during the operation of ITER. (author). 33 refs

  3. Electromagnetic impact by microcellular base stations: analysis and guidelines for a correct setting up

    International Nuclear Information System (INIS)

    Licitra, G.; Reggiani, M.; Silvi, A.M.; Zari, A.; Ricci, A.

    2002-01-01

    During the last few years the development of mobile communications has required ever increasing number of base stations for both existing mobile operators and new ones. More and more users ask for a higher quality services so new technological solutions have been studied and applied to assure effective coverage for given geographical areas, as in squares or narrow streets, characterized by a very high traffic demand or where coverage by usual macro cells is very difficult. On the other side, modern societies of developed countries ask for a better and better quality of life and appropriate government policies. Several studies of national and international scientific organizations have been performed and are still in progress to establish any possible adverse effects on human health of non-ionizing radiation exposure. So, many governments, forced by public opinion pressure, have produced specific standards in agreement with scientific organization guidelines and prudent avoidance politics too. Nowadays, designing their networks, mobile operators have to respect requirements contained in these standards. So a hierarchical cellular system have been recently proposed to comply more easily with both coverage requirements and lower exposure limits. This new coverage strategy of geographical areas requires the presence of microcells beside the usual macro cells. In this paper the study of the distribution of the electromagnetic field levels produced by microcellular base stations characterized by different features and configurations is presented, in order to define a few guidelines for the correct setting up of antennas in compliance with current standard requirements. This is obtained comparing results of theoretical modeling, based on the radio electrical characteristics of each sources, and measurements data. Results achieved by measurements performed on a preliminary sample of microcells have been presented in this work

  4. IRIS PRA preliminary results and future direction

    International Nuclear Information System (INIS)

    Finnicum, D.J.; Kling, C.L.; Carelli, M.D.

    2004-01-01

    Westinghouse is currently conducting the pre-application licensing of the International Reactor Innovative and Secure (IRIS) on behalf of the IRIS Consortium. One of the key aspects of the IRIS design is the concept of safety-by-design. The PRA (Probabilistic Risk Analysis) is being used as an integral part of the design process. As part of this effort, a PRA of the initial design was generated to address 2 key areas. First, the IRIS PRA supported the evaluation of IRIS design issues by providing a solid risk basis for design and analyses required for the pre-licensing evaluation of the IRIS design. The PRA provides the tool for quantifying the benefit of the safety-by-design approach. Second, the current PRA task is beginning the preparation of the more complete PRA analyses and documentation eventually required for Design Certification. One of the key risk-related goals for IRIS is to reduce the EPZ (Emergency Protection Zone) to within the exclusion area by demonstrating that the off-site doses are consistent with the US Protective Action Guidelines (PAGs) for initiation of emergency response so that the required protective actions would be limited to the exclusion area. The results of the preliminary PRA indicated a core damage frequency of 1.2 E-08 for internal initiators. This is a very good result but much work is needed to meet the ambitious goal of no emergency response. The next phase of the PRA analyses will involve a two-fold expansion of the PRA. First, as the design and analyses approach a greater level of detail, the assumptions used for the initial PRA will be reviewed and the models will be revised as needed to reflect the improved knowledge of the system design and performance. Furthermore, as the full plant design advances, the PRA will be expanded to incorporate risk associated with external challenges such as seismic and fire, and to address low power and shutdowns modes of operation. As with the initial work, the PRA will serve as a tool to

  5. The European Standards and Guidelines and the Evaluation of Agencies in Germany

    Science.gov (United States)

    Hopbach, Achim

    2006-01-01

    This paper presents preliminary findings from the application of the European Standards and Guidelines (ESG) to the Accreditation Council's accreditation criteria and the review of three German accreditation agencies done by the German Accreditation Council. It focuses on the main characteristics of the ESG and their implementation into the German…

  6. IT governance guidelines for directors

    CERN Document Server

    Calder, Alan

    2005-01-01

    This important new book – 'IT Governance: Guidelines for Directors' provides directors, executives, managers and professional advisers with clear, pragmatic guidelines for ensuring that IT and the business work together for the same strategic objectives. 

  7. [Guideline 'Organ donation following euthanasia"

    NARCIS (Netherlands)

    Mulder, H.; Olthuis, G.J.; Siebelink, M.; Gerritsen, R; Heurn, E. van

    2017-01-01

    - The multidisciplinary guideline 'Organ donation following euthanasia' was published in March 2017 at request of the Minister of Health, Welfare and Sport.- This guideline provides recommendations for the organisation and implementation of a request to donate organs expressed by a patient who asks

  8. The nuclear codes and guidelines

    International Nuclear Information System (INIS)

    Sonter, M.

    1984-01-01

    This paper considers problems faced by the mining industry when implementing the nuclear codes of practice. Errors of interpretation are likely. A major criticism is that the guidelines to the codes must be seen as recommendations only. They are not regulations. Specific clauses in the guidelines are criticised

  9. Specialty Guidelines for Forensic Psychology

    Science.gov (United States)

    American Psychologist, 2013

    2013-01-01

    In the past 50 years forensic psychological practice has expanded dramatically. Because the practice of forensic psychology differs in important ways from more traditional practice areas (Monahan, 1980) the "Specialty Guidelines for Forensic Psychologists" were developed and published in 1991 (Committee on Ethical Guidelines for Forensic…

  10. Journal of Wildlife Management guidelines

    Science.gov (United States)

    William M. Block; Frank R. Thompson; Dawn Hanseder; Allison Cox; Anna Knipps

    2011-01-01

    These Guidelines apply to all Journal of Wildlife Management (JWM, The Journal) submissions. Publishing a professional manuscript proceeds most smoothly if authors understand the policy, procedures, format, and style of the outlet to which they are submitting a manuscript. These instructions supersede all previous guidelines. Manuscripts that clearly deviate from this...

  11. PIAAC Technical Standards and Guidelines

    Science.gov (United States)

    OECD Publishing, 2014

    2014-01-01

    The Programme for International Assessment of Adult Competencies (PIAAC) will establish technical standards and guidelines to ensure that the survey design and implementation processes of PIAAC yield high-quality and internationally comparable data. This document provides a revised version of the technical standards and guidelines originally…

  12. Air quality guidelines for arenas in Nova Scotia

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-05-01

    A series of guidelines have been prepared to address the quality of air in skating arena facilities in Nova Scotia. They are limited to carbon monoxide and nitrogen dioxide emissions. Average nitrogen dioxide levels should not exceed 1 part per million (ppm). Average carbon monoxide levels should not exceed 25 ppm. These guidelines do not address other contaminants such as ammonia or chlorofluorocarbons (CFCs). The guidelines are considered to be the minimum standards required for safe arena operations. These standards can be met by reducing emissions of the ice resurfacer and edger which is one of the major sources of poor air quality in arenas. Other ways to meet the standards are to ensure proper equipment operation, ventilation and monitoring of indoor air quality levels. Symptoms of exposure and potential consequences were also described. It was noted that owners and operators may be found libel for injury if a proper environment is not maintained. 6 appendices.

  13. Testing post-editing guidelines

    DEFF Research Database (Denmark)

    Flanagan, Marian; Christensen, Tina Paulsen

    2014-01-01

    guidelines to use in translator training programmes. Recently, the first set of publicly available industry-focused PE guidelines (for ‘good enough’ and ‘publishable’ quality) were developed by Translation Automation User Society (TAUS) in partnership with the Centre for Global Intelligent Content (CNGL......), which can be used as a basis on which to instruct post-editors in professional environments. This paper reports on a qualitative study that investigates how trainee translators on an MA course, which is aimed at preparing the trainees for the translation industry, interpret these PE guidelines...... for publishable quality. The findings suggest trainees have difficulties interpreting the guidelines, primarily due to trainee competency gaps, but also due to the wording of the guidelines. Based on our findings we propose training measures to address these competency gaps. Furthermore, we provide post...

  14. Guidelines on Building Regulations 2008

    DEFF Research Database (Denmark)

    Thse guidelines clarify and intepret the provisions of the Building Regulations of 2008 (BR08). The Guidelines, which match BR08 in terms of organisation into Parts, are accompanied by the full text of the regulations and the explanatory notes issued by the Danish Enterprise and Construction...... Authority. The Guidelines refer the reader to sources such as relevant standards, instructions and other background material which provides more detailed information. The Guidelines cover the same ground as BR08, including building control regulations, layout, fitting out, structures, fire safety, indoor...... climate, energy consumotion and services. The Guidelines are aimed at all professionals involved in building projects, particularly building design consultants, contractors and municipal application officers....

  15. ESUR prostate MR guidelines 2012

    DEFF Research Database (Denmark)

    Barentsz, Jelle O; Richenberg, Jonathan; Clements, Richard

    2012-01-01

    The aim was to develop clinical guidelines for multi-parametric MRI of the prostate by a group of prostate MRI experts from the European Society of Urogenital Radiology (ESUR), based on literature evidence and consensus expert opinion. True evidence-based guidelines could not be formulated......, but a compromise, reflected by "minimal" and "optimal" requirements has been made. The scope of these ESUR guidelines is to promulgate high quality MRI in acquisition and evaluation with the correct indications for prostate cancer across the whole of Europe and eventually outside Europe. The guidelines...... provides guidelines for magnetic resonance imaging (MRI) in prostate cancer. Clinical indications, and minimal and optimal imaging acquisition protocols are provided. A structured reporting system (PI-RADS) is described....

  16. [French guidelines on electroencephalogram].

    Science.gov (United States)

    André-Obadia, N; Sauleau, P; Cheliout-Heraut, F; Convers, P; Debs, R; Eisermann, M; Gavaret, M; Isnard, J; Jung, J; Kaminska, A; Kubis, N; Lemesle, M; Maillard, L; Mazzola, L; Michel, V; Montavont, A; N'Guyen, S; Navarro, V; Parain, D; Perin, B; Rosenberg, S D; Sediri, H; Soufflet, C; Szurhaj, W; Taussig, D; Touzery-de Villepin, A; Vercueil, L; Lamblin, M D

    2014-12-01

    Electroencephalography allows the functional analysis of electrical brain cortical activity and is the gold standard for analyzing electrophysiological processes involved in epilepsy but also in several other dysfunctions of the central nervous system. Morphological imaging yields complementary data, yet it cannot replace the essential functional analysis tool that is EEG. Furthermore, EEG has the great advantage of being non-invasive, easy to perform and allows control tests when follow-up is necessary, even at the patient's bedside. Faced with the advances in knowledge, techniques and indications, the Société de Neurophysiologie Clinique de Langue Française (SNCLF) and the Ligue Française Contre l'Épilepsie (LFCE) found it necessary to provide an update on EEG recommendations. This article will review the methodology applied to this work, refine the various topics detailed in the following chapters. It will go over the summary of recommendations for each of these chapters and underline proposals for writing an EEG report. Some questions could not be answered by the review of the literature; in those cases, an expert advice was given by the working and reading groups in addition to the guidelines. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  17. Wind and tornado guidelines

    International Nuclear Information System (INIS)

    McDonald, J.R.

    1989-01-01

    The objective of the Department of Energy Natural Phenomena Hazards Project is to provide guidance and criteria for design of new facilities and for evaluation of existing ones subjected to extreme winds, earthquakes, and floods. This paper describes the treatment of wind and tornado hazards. Four facility-use categories are defined which represent increasing levels of risk to personnel or the environment in the event of a high wind event. Facilities are assigned to a particular category, depending on their mission, value, or toxic material content. The assigned facility-use category determines the design and evaluation criteria. The criteria are based on probabilistic hazard assessment. Performance goals are also specified for each facility-use category. A uniform approach to design wind loads, based on the ANSI A58.1-1982 standard, allows treatment of high winds and hurricane and tornado winds in a similar manner. Based on the wind hazard models, some sites must account for the possibility of tornadoes while others do not. Atmospheric pressure changes and missiles must be taken into account when considering tornadoes. The design and evaluation guidelines are designed to establish consistent levels of risk for different natural phenomena hazards and for facilities at different geographical locations

  18. Guideline level-3 PSA

    International Nuclear Information System (INIS)

    Roelofsen, P.M.; Van der Steen, J.

    1993-09-01

    For several applications of radioactive materials calculations must be executed to determine the radiation risk for the population. A guideline for the risk calculation method of two main sources: nuclear power plants, and other intended and unintended activities with radioactive materials, is given. The standards, recommendations and regulations in this report concern mainly the analysis of the radiological (external) consequences of nuclear power plant accidents, classified as level-3 PSA (Probabilistic Safety Analysis). Level-3 PSA falls within the scales 5-7 of the International Nuclear Event Scale (INES). The standards, etc., focus on the risks for groups of people and the so-called maximum individual risk. In chapter two the standards and regulations are formulated for each part of level-3 PSA: the source term spectrum, atmospheric distribution and deposition, exposure to radiation doses and calculation of radiation doses, dose-response relationships, measures to reduce the effect of radiation doses, design basis accidents, and finally uncertainty analysis. In chapter four, modelled descriptions are given of the standards and regulations, which could or should be used in a calculation program in case of level-3 PSA. In chapter three the practical execution of a probabilistic consequences analysis, the collection of input data and the presentation of the results are dealt with. 2 figs., 14 tabs., 64 refs

  19. Advanced human-system interface design review guideline. General evaluation model, technical development, and guideline description

    Energy Technology Data Exchange (ETDEWEB)

    O`Hara, J.M.

    1994-07-01

    Advanced control rooms will use advanced human-system interface (HSI) technologies that may have significant implications for plant safety in that they will affect the operator`s overall role in the system, the method of information presentation, and the ways in which operators interact with the system. The U.S. Nuclear Regulatory Commission (NRC) reviews the HSI aspects of control rooms to ensure that they are designed to good human factors engineering principles and that operator performance and reliability are appropriately supported to protect public health and safety. The principal guidance available to the NRC, however, was developed more than ten years ago, well before these technological changes. Accordingly, the human factors guidance needs to be updated to serve as the basis for NRC review of these advanced designs. The purpose of this project was to develop a general approach to advanced HSI review and the human factors guidelines to support NRC safety reviews of advanced systems. This two-volume report provides the results of the project. Volume I describes the development of the Advanced HSI Design Review Guideline (DRG) including (1) its theoretical and technical foundation, (2) a general model for the review of advanced HSIs, (3) guideline development in both hard-copy and computer-based versions, and (4) the tests and evaluations performed to develop and validate the DRG. Volume I also includes a discussion of the gaps in available guidance and a methodology for addressing them. Volume 2 provides the guidelines to be used for advanced HSI review and the procedures for their use.

  20. Cost and Operational Effectiveness Analysis of Aiternative Force Structures for Fulfillment of the United States Marine Corps Operational Support Airlift and Search and Rescue Missions

    National Research Council Canada - National Science Library

    Chase, Eric

    2000-01-01

    This thesis provides a preliminary cost and operational effectiveness analysis of alternative force structures for the United States Marine Corps operational support airlift and search and rescue missions...

  1. Guidelines for the regulatory review of the human reliability analysis in PSAs

    International Nuclear Information System (INIS)

    Reer, Bernhard; Dang, V.N.; Hirschberg, Stefan; Meyer, Patrick

    2000-01-01

    In the review guidelines recently developed for the Swiss Federal Nuclear Inspectorate, the Human Reliability Analysis (HRA) is reviewed in two stages. The preliminary review is aimed at identifying major shortcomings and potential issues to be examined in the detailed review. The detailed review comprehensively addresses the overall adequacy and transparency of the HRA. For the two review stages, 97 indicators are defined in terms of questions focusing on verifiable features of the methodology, implementation and results. The guidelines provide steps for information gathering and present examples of acceptable practices as well as of potential deficiencies. Both review stages may result in requests for clarification, additional documentation or analyses. The first applications of the guidelines consist of the preliminary reviews of two HRAs. (author)

  2. Developing clinical practice guidelines: target audiences, identifying topics for guidelines, guideline group composition and functioning and conflicts of interest.

    Science.gov (United States)

    Eccles, Martin P; Grimshaw, Jeremy M; Shekelle, Paul; Schünemann, Holger J; Woolf, Steven

    2012-07-04

    Clinical practice guidelines are one of the foundations of efforts to improve health care. In 1999, we authored a paper about methods to develop guidelines. Since it was published, the methods of guideline development have progressed both in terms of methods and necessary procedures and the context for guideline development has changed with the emergence of guideline clearing houses and large scale guideline production organisations (such as the UK National Institute for Health and Clinical Excellence). It therefore seems timely to, in a series of three articles, update and extend our earlier paper. In this first paper we discuss: the target audience(s) for guidelines and their use of guidelines; identifying topics for guidelines; guideline group composition (including consumer involvement) and the processes by which guideline groups function and the important procedural issue of managing conflicts of interest in guideline development.

  3. Adolescent Pregnancy Guidelines.

    Science.gov (United States)

    Fleming, Nathalie; O'Driscoll, Teresa; Becker, Gisela; Spitzer, Rachel F

    2015-08-01

    To describe the needs and evidence-based practice specific to care of the pregnant adolescent in Canada, including special populations. Healthy pregnancies for adolescent women in Canada, with culturally sensitive and age-appropriate care to ensure the best possible outcomes for these young women and their infants and young families, and to reduce repeat pregnancy rates. Published literature was retrieved through searches of PubMed and The Cochrane Library on May 23, 2012 using appropriate controlled vocabulary (e.g., Pregnancy in Adolescence) and key words (e.g., pregnancy, teen, youth). Results were restricted to systematic reviews, randomized control trials/controlled clinical trials, and observational studies. Results were limited to English or French language materials published in or after 1990. Searches were updated on a regular basis and incorporated in the guideline to July 6, 2013. Grey (unpublished) literature was identified through searching the websites of health technology assessment and health technology-related agencies, national and international medical specialty societies, and clinical practice guideline collections. The quality of evidence in this document was rated using the criteria described in the Report of the Canadian Task Force on Preventive Health Care (Table 1). BENEFITS/HARMS/COSTS: These guidelines are designed to help practitioners caring for adolescent women during pregnancy in Canada and allow them to take the best care of these young women in a manner appropriate for their age, cultural backgrounds, and risk profiles. 1. Health care providers should adapt their prenatal care for adolescents and offer multidisciplinary care that is easily accessible to the adolescent early in the pregnancy, recognizing that adolescents often present to care later than their adult counterparts. A model that provides an opportunity to address all of these needs at one site may be the preferred model of care for pregnant adolescents. (II-1A) 2. Health

  4. Procurement guideline for oil recovery boats; Oeljyntorjuntaveneen hankintaohje

    Energy Technology Data Exchange (ETDEWEB)

    Pajala, J.

    2011-12-15

    These guidelines have been compiled to assist in the procurement of oil recovery boats, with the intention of ensuring that new boats meet the future needs of oil spill response operations and that procurement will be carried out in a manner that is economically sound and technologically well-founded. Furthermore, the guidelines are intended to encourage the development and adoption of new solutions for oil recovery boats. The issues covered by these guidelines include: Multiple uses of boats, classification of boats and class-specific requirements, the principle of sustainable development and the boats' lifecycle, qualification to be set for the crews, procurement timeline, regulations and guidelines, inspections and approvals. (orig.)

  5. Guidelines for Management Information Systems in Canadian Health Care Facilities

    Science.gov (United States)

    Thompson, Larry E.

    1987-01-01

    The MIS Guidelines are a comprehensive set of standards for health care facilities for the recording of staffing, financial, workload, patient care and other management information. The Guidelines enable health care facilities to develop management information systems which identify resources, costs and products to more effectively forecast and control costs and utilize resources to their maximum potential as well as provide improved comparability of operations. The MIS Guidelines were produced by the Management Information Systems (MIS) Project, a cooperative effort of the federal and provincial governments, provincial hospital/health associations, under the authority of the Canadian Federal/Provincial Advisory Committee on Institutional and Medical Services. The Guidelines are currently being implemented on a “test” basis in ten health care facilities across Canada and portions integrated in government reporting as finalized.

  6. Guidelines for Waste Accumulation Areas (WAAs)

    International Nuclear Information System (INIS)

    1991-07-01

    The purpose of this document is to set conditions for establishing and maintaining areas for the accumulation of hazardous waste at LBL. Areas designed for accumulation of these wastes in quantities greater than 100 kg (220 lb) per month of solid waste or 55 gallons per month of liquid waste are called Waste Accumulation Areas (WAAs). Areas designed for accumulation of wastes in smaller amounts are called Satellite Accumulation Areas (SAAs). This document provides guidelines for employee and organizational responsibilities for WAAs; constructing a WAA; storing waste in a WAA; operating and maintaining a WAA, and responding to spills in a WAA. 4 figs

  7. Guidelines for radiological monitoring of the environment

    International Nuclear Information System (INIS)

    1990-11-01

    This Standard provides criteria to be used in deciding whether an environmental monitoring program is required for a given nuclear facility. It also sets out a systematic approach to monitoring the environment, which is considered to be outside the facility boundary. It provides guidelines for establishing an environmental program covering sampling and analysis protocols, analytical techniques and sensitivity, statistical treatment of monitoring results, quality assurance, methods for expressing results, and record keeping. The standard applies to the environment of a nuclear facility operating mainly under normal conditions; in addition, certain of these requirements may also apply to situations involving abnormal releases

  8. Singapore Paediatric Resuscitation Guidelines 2016.

    Science.gov (United States)

    Ong, Gene Yong Kwang; Chan, Irene Lai Yeen; Ng, Agnes Suah Bwee; Chew, Su Yah; Mok, Yee Hui; Chan, Yoke Hwee; Ong, Jacqueline Soo May; Ganapathy, Sashikumar; Ng, Kee Chong

    2017-07-01

    We present the revised 2016 Singapore paediatric resuscitation guidelines. The International Liaison Committee on Resuscitation's Pediatric Taskforce Consensus Statements on Science and Treatment Recommendations, as well as the updated resuscitation guidelines from the American Heart Association and European Resuscitation Council released in October 2015, were debated and discussed by the workgroup. The final recommendations for the Singapore Paediatric Resuscitation Guidelines 2016 were derived after carefully reviewing the current available evidence in the literature and balancing it with local clinical practice. Copyright: © Singapore Medical Association.

  9. Implementation guidelines for seismic PSA

    International Nuclear Information System (INIS)

    Coman, Ovidiu; Samaddar, Sujit; Hibino, Kenta; )

    2014-01-01

    The presentation was devoted to development of guidelines for implementation of a seismic PSA. If successful, these guidelines can close an important gap. ASME/ANS PRA standards and the related IAEA Safety Guide (IAEA NS-G-2.13) describe capability requirements for seismic PSA in order to support risk-informed applications. However, practical guidance on how to meet these requirements is limited. Such guidelines could significantly contribute to improving risk-informed safety demonstration, safety management and decision making. Extensions of this effort to further PSA areas, particularly to PSA for other external hazards, can enhance risk-informed applications

  10. Guidelines for Reporting Medical Research

    DEFF Research Database (Denmark)

    Johansen, Mathilde; Thomsen, Simon Francis

    2016-01-01

    As a response to a low quality of reporting of medical research, guidelines for several different types of study design have been developed to secure accurate reporting and transparency for reviewers and readers from the scientific community. Herein, we review and discuss the six most widely...... accepted and used guidelines: PRISMA, CONSORT, STROBE, MOOSE, STARD, and SPIRIT. It is concluded that the implementation of these guidelines has led to only a moderate improvement in the quality of the reporting of medical research. There is still much work to be done to achieve accurate and transparent...... reporting of medical research findings....

  11. Environmental Design Guidelines for Low Crested Coastal Structures

    DEFF Research Database (Denmark)

    Burcharth, Hans F.; Hawkins, Stephen J.; Zanuttigh, Barbara

    selected to represent a variety of environmental conditions (Chapter 11); the application of the proposed methodology to a real prototype case, in order to give a practical example to designers (Chapter 12). The third part contains all the formulae and tools to help engineers (Chapter 13), ecologists....... The guidelines have been drafted in a generic way to be appropriate throughout the European Union taking into regard current European Commission policy and directives to promote sustainable development and integrated coastal zone management. The guidelines are composed of three main parts. The first part...... (Chapters 1-10) contains the description of the design methodology, from the preliminary identification of design alternatives till the selection of the sustainable scheme and its construction. The second part presents: the analysis of the performance of beach defences in DELOS study sites, which were...

  12. Metric Guidelines Inservice and/or Preservice

    Science.gov (United States)

    Granito, Dolores

    1978-01-01

    Guidelines are given for designing teacher training for going metric. The guidelines were developed from existing guidelines, journal articles, a survey of colleges, and the detailed reactions of a panel. (MN)

  13. Treatise on water hammer in hydropower standards and guidelines

    International Nuclear Information System (INIS)

    Bergant, A; Mazij, J; Karney, B; Pejović, S

    2014-01-01

    This paper reviews critical water hammer parameters as they are presented in official hydropower standards and guidelines. A particular emphasize is given to a number of IEC standards and guidelines that are used worldwide. The paper critically assesses water hammer control strategies including operational scenarios (closing and opening laws), surge control devices (surge tank, pressure regulating valve, flywheel, etc.), redesign of the water conveyance system components (tunnel, penstock), or limitation of operating conditions (limited operating range) that are variably covered in standards and guidelines. Little information is given on industrial water hammer models and solutions elsewhere. These are briefly introduced and discussed in the light of capability (simple versus complex systems), availability of expertise (in house and/or commercial) and uncertainty. The paper concludes with an interesting water hammer case study referencing the rules and recommendations from existing hydropower standards and guidelines in a view of effective water hammer control. Recommendations are given for further work on development of a special guideline on water hammer (hydraulic transients) in hydropower plants

  14. Treatise on water hammer in hydropower standards and guidelines

    Science.gov (United States)

    Bergant, A.; Karney, B.; Pejović, S.; Mazij, J.

    2014-03-01

    This paper reviews critical water hammer parameters as they are presented in official hydropower standards and guidelines. A particular emphasize is given to a number of IEC standards and guidelines that are used worldwide. The paper critically assesses water hammer control strategies including operational scenarios (closing and opening laws), surge control devices (surge tank, pressure regulating valve, flywheel, etc.), redesign of the water conveyance system components (tunnel, penstock), or limitation of operating conditions (limited operating range) that are variably covered in standards and guidelines. Little information is given on industrial water hammer models and solutions elsewhere. These are briefly introduced and discussed in the light of capability (simple versus complex systems), availability of expertise (in house and/or commercial) and uncertainty. The paper concludes with an interesting water hammer case study referencing the rules and recommendations from existing hydropower standards and guidelines in a view of effective water hammer control. Recommendations are given for further work on development of a special guideline on water hammer (hydraulic transients) in hydropower plants.

  15. Optimisation of small-scale hydropower using quality assurance methods - Preliminary project; Vorprojekt: Optimierung von Kleinwasserkraftwerken durch Qualitaetssicherung. Programm Kleinwasserkraftwerke

    Energy Technology Data Exchange (ETDEWEB)

    Hofer, S.; Staubli, T.

    2006-11-15

    This comprehensive final report for the Swiss Federal Office of Energy (SFOE) presents the results of a preliminary project that examined how quality assurance methods can be used in the optimisation of small-scale hydropower projects. The aim of the project, to use existing know-how, experience and synergies, is examined. Discrepancies in quality and their effects on production prices were determined in interviews. The paper describes best-practice guidelines for the quality assurance of small-scale hydro schemes. A flow chart describes the various steps that have to be taken in the project and realisation work. Information collected from planners and from interviews made with them are presented along with further information obtained from literature. The results of interviews concerning planning work, putting to tender and the construction stages of these hydro schemes are presented and commented on. Similarly, the operational phase of such power plant is also examined, including questions on operation and guarantees. The aims of the follow-up main project - the definition of a tool and guidelines for ensuring quality - are briefly reviewed.

  16. Advanced human-system interface design review guideline. General evaluation model, technical development, and guideline description

    International Nuclear Information System (INIS)

    O'Hara, J.M.

    1994-07-01

    Advanced control rooms will use advanced human-system interface (HSI) technologies that may have significant implications for plant safety in that they will affect the operator's overall role in the system, the method of information presentation, and the ways in which operators interact with the system. The U.S. Nuclear Regulatory Commission (NRC) reviews the HSI aspects of control rooms to ensure that they are designed to good human factors engineering principles and that operator performance and reliability are appropriately supported to protect public health and safety. The principal guidance available to the NRC, however, was developed more than ten years ago, well before these technological changes. Accordingly, the human factors guidance needs to be updated to serve as the basis for NRC review of these advanced designs. The purpose of this project was to develop a general approach to advanced HSI review and the human factors guidelines to support NRC safety reviews of advanced systems. This two-volume report provides the results of the project. Volume I describes the development of the Advanced HSI Design Review Guideline (DRG) including (1) its theoretical and technical foundation, (2) a general model for the review of advanced HSIs, (3) guideline development in both hard-copy and computer-based versions, and (4) the tests and evaluations performed to develop and validate the DRG. Volume I also includes a discussion of the gaps in available guidance and a methodology for addressing them. Volume 2 provides the guidelines to be used for advanced HSI review and the procedures for their use

  17. Siting guidelines and their role in repository site selection

    International Nuclear Information System (INIS)

    Hanlon, C.L.

    1985-01-01

    The first requirement of the Nuclear Waste Policy Act was for the Secretary of Energy to issue general guidelines for siting repositories. The guidelines were to specify detailed geologic considerations that would be the primary criteria for the selection of sites in various host rocks, as well as factors that would qualify or disqualify any site from development as a repository. These guidelines were clearly intended to provide not only the framework for the siting program but also the stimulus for establishing effective communication and consultation among the parties involved in the program. The Act further required that the guidelines be a factor in the development of all future decision documents of the Office of Civilian Radioactive Waste Management, including the environmental assessments that would accompany the nomination of sites for characterization, the site-characterization plans that are to be prepared before the sinking of exploratory shafts at any candidate site, and the environmental impact statement that is to support the recommendation of a site for development as a repository. More than two years after its passage, the intention of the Act for the guidelines has been realized. Concurred in by the Nuclear Regulatory Commission on June 22, 1984, and issued by the Department in November 1984, the guidelines include postclosure technical guidelines that apply to conditions governing the long-term performance of the repository system; preclosure technical guidelines that apply to conditions governing the siting, construction, operation, and closure of the repository; and system guidelines whose objective is to ensure that the regulatory requirements of the Environmental Protection Agency and the Nuclear Regulatory Commission are met

  18. Functional Hypothalamic Amenorrhea: An Endocrine Society Clinical Practice Guideline.

    Science.gov (United States)

    Gordon, Catherine M; Ackerman, Kathryn E; Berga, Sarah L; Kaplan, Jay R; Mastorakos, George; Misra, Madhusmita; Murad, M Hassan; Santoro, Nanette F; Warren, Michelle P

    2017-05-01

    The American Society for Reproductive Medicine, the European Society of Endocrinology, and the Pediatric Endocrine Society. This guideline was funded by the Endocrine Society. To formulate clinical practice guidelines for the diagnosis and treatment of functional hypothalamic amenorrhea (FHA). The participants include an Endocrine Society-appointed task force of eight experts, a methodologist, and a medical writer. This evidence-based guideline was developed using the Grading of Recommendations, Assessment, Development, and Evaluation approach to describe the strength of recommendations and the quality of evidence. The task force commissioned two systematic reviews and used the best available evidence from other published systematic reviews and individual studies. One group meeting, several conference calls, and e-mail communications enabled consensus. Endocrine Society committees and members and cosponsoring organizations reviewed and commented on preliminary drafts of this guideline. FHA is a form of chronic anovulation, not due to identifiable organic causes, but often associated with stress, weight loss, excessive exercise, or a combination thereof. Investigations should include assessment of systemic and endocrinologic etiologies, as FHA is a diagnosis of exclusion. A multidisciplinary treatment approach is necessary, including medical, dietary, and mental health support. Medical complications include, among others, bone loss and infertility, and appropriate therapies are under debate and investigation. Copyright © 2017 Endocrine Society

  19. Guidelines for a radiology department

    International Nuclear Information System (INIS)

    1981-05-01

    This manual presents guidelines for hospitals on a radiology quality assurance and dose measurement audit program and a system of planned actions that monitor and record the performance and effectiveness of the radiological service

  20. ASSET guidelines. Revised 1991 Edition

    International Nuclear Information System (INIS)

    1991-12-01

    The present publication is an updated version of the IAEA Assessment of Safety Significant Events Team (ASSET) Guidelines, IAEA-TECDOC-573, published in 1990. Sections 5 and 6 include revised definitions and investigation guidelines for identification of both direct and root causes. These revisions were recommended by a Consultants Meeting held in Vienna on 3-7 December 1990. This guidance is not intended to infringe an expert's prerogative to investigate additional items. Its main purpose is to provide a basic structure and ensure consistency in the assessments. Use of the ASSET guidelines should also facilitate comparison between the observations made in different nuclear power plants and harmonize the reporting of generic ASSET results. The guidelines should always be used with a critical attitude and a view to possible improvements

  1. Measure Guideline: Basement Insulation Basics

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, R.; Mantha, P.; Puttagunta, S.

    2012-10-01

    This guideline is intended to describe good practices for insulating basements in new and existing homes, and is intended to be a practical resources for building contractors, designers, and also to homeowners.

  2. Guidelines for direct radionuclide cystography

    International Nuclear Information System (INIS)

    Fettich, J.; Colarinha, P.; Fischer, S.; Hahn, K.; Porn, U.; Froekier, J.; Gordon, I.; Kabasakal, L.; Mann, M.; Mitjavila, M.; Olivier, P.; Piepsz, A.; Roca, I.; Sixt, R.; Velzen, J. van

    2002-01-01

    These ''Empfehlungen'' are the german translation of the Guidelines on MIBG-Scintigraphy in Children, which were published by the Paediatric Committee of the European Association of Nuclear Medicine. (orig.) [de

  3. Lupus nephritis management guidelines compared.

    Science.gov (United States)

    Wilhelmus, Suzanne; Bajema, Ingeborg M; Bertsias, George K; Boumpas, Dimitrios T; Gordon, Caroline; Lightstone, Liz; Tesar, Vladimir; Jayne, David R

    2016-06-01

    In the past years, many (randomized) trials have been performed comparing the treatment strategies for lupus nephritis. In 2012, these data were incorporated in six different guidelines for treating lupus nephritis. These guidelines are European, American and internationally based, with one separate guideline for children. They offer information on different aspects of the management of lupus nephritis including induction and maintenance treatment of the different histological classes, adjunctive treatment, monitoring of the patient, definitions of response and relapse, indications for (repeat) renal biopsy, and additional challenges such as the presence of vascular complications, the pregnant SLE patient, treatment in children and adolescents and considerations about end-stage renal disease and transplantation. In this review, we summarize the guidelines, determine the common ground between them, highlight the differences and discuss recent literature. © The Author 2015. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  4. Total quality management implementation guidelines

    Energy Technology Data Exchange (ETDEWEB)

    1993-12-01

    These Guidelines were designed by the Energy Quality Council to help managers and supervisors in the Department of Energy Complex bring Total Quality Management to their organizations. Because the Department is composed of a rich mixture of diverse organizations, each with its own distinctive culture and quality history, these Guidelines are intended to be adapted by users to meet the particular needs of their organizations. For example, for organizations that are well along on their quality journeys and may already have achieved quality results, these Guidelines will provide a consistent methodology and terminology reference to foster their alignment with the overall Energy quality initiative. For organizations that are just beginning their quality journeys, these Guidelines will serve as a startup manual on quality principles applied in the Energy context.

  5. [Preoperative fasting guidelines: an update].

    Science.gov (United States)

    López Muñoz, A C; Busto Aguirreurreta, N; Tomás Braulio, J

    2015-03-01

    Anesthesiology societies have issued various guidelines on preoperative fasting since 1990, not only to decrease the incidence of lung aspiration and anesthetic morbidity, but also to increase patient comfort prior to anesthesia. Some of these societies have been updating their guidelines, as such that, since 2010, we now have 2 evidence-based preoperative fasting guidelines available. In this article, an attempt is made to review these updated guidelines, as well as the current instructions for more controversial patients such as infants, the obese, and a particular type of ophthalmic surgery. Copyright © 2014 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. FDH radiological design review guidelines

    International Nuclear Information System (INIS)

    Millsap, W.J.

    1998-01-01

    These guidelines discuss in more detail the radiological design review process used by the Project Hanford Management Contractors as described in HNF-PRO-1622, Radiological Design Review Process. They are intended to supplement the procedure by providing background information on the design review process and providing a ready source of information to design reviewers. The guidelines are not intended to contain all the information in the procedure, but at points, in order to maintain continuity, they contain some of the same information

  7. FDH radiological design review guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Millsap, W.J.

    1998-09-29

    These guidelines discuss in more detail the radiological design review process used by the Project Hanford Management Contractors as described in HNF-PRO-1622, Radiological Design Review Process. They are intended to supplement the procedure by providing background information on the design review process and providing a ready source of information to design reviewers. The guidelines are not intended to contain all the information in the procedure, but at points, in order to maintain continuity, they contain some of the same information.

  8. Advanced control room design review guidelines: Merging old and new

    International Nuclear Information System (INIS)

    Carter, R.J.; Wachtel, J.A.

    1992-01-01

    The nuclear power industry is currently developing operator interface systems based on innovative applications of digital computers. To assure that this advanced technology is incorporated in a way that maximizes the potential safety benefits of the technology and minimizes the potential negative effects on human performance, human factors principles must be considered. NUREG-0700 contains guidelines for the review of operator interfaces. However, in light of the rapid technological advances in digital technology which have taken place in the eleven years since its publication, it is no longer adequate to assess the rapidly changing human-system interfaces. A research program, the purpose of which is to upgrade NUREG-0700, has been initiated. Thus far a set of draft advanced control room design review (ACRDR) guidelines has been complied. Three tasks, which were oriented towards integrating the applicable guidelines in NUREG-0700 into the ACRDR document, are described in the paper

  9. Public safety around dams guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, T [Canadian Dam Association, Edmonton, AB (Canada)

    2010-07-01

    This presentation discussed Canadian and international initiatives for improving dam safety and described some of the drivers for the development of new Canadian Dam Association (CDA) public safety guidelines for dams. The CDA guidelines were divided into the following 3 principal sections: (1) managed system elements, (2) risk assessment and management, and (3) technical bulletins. Public and media responses to the drownings have called for improved safety guidelines. While the public remains unaware of the hazards of dams, public interaction with dams is increasing as a result of interest in extreme sports and perceived rights of access. Guidelines are needed for dam owners in order to provide due diligence. Various organizations in Canada are preparing technical and public safety dam guidelines. CDA guidelines have also been prepared for signage, booms and buoys, and audible and visual alerts bulletins. Working groups are also discussing recommended practices for spill procedures, spillways and the role of professional engineers in ensuring public safety. Methods of assessing risk were also reviewed. Managed system elements for risk assessment and public interactions were also discussed, and stepped control measures were presented. tabs., figs.

  10. Mexican Asthma Guidelines: GUIMA 2017

    Directory of Open Access Journals (Sweden)

    Désirée Larenas-Linnemann

    2017-04-01

    Full Text Available Background: The need for a national guideline, with a broad basis among specialists and primary care physicians was felt in Mexico, to try unifying asthma management. As several high-quality asthma guidelines exist worldwide, it was decided to select the best three for transculturation. Methods: Following the internationally recommended methodology for guideline transculturation, ADAPTE, a literature search for asthma guidelines, published 1-1-2007 through 31-12-2015 was conducted. AGREE-II evaluations yielded 3/40 most suitable for transculturation. Their compound evidence was fused with local reality, patient preference, cost and safety considerations to draft the guideline document. Subsequently, this was adjusted by physicians from 12 national medical societies in several rounds of a Delphi process and 3 face-to-face meetings to reach the final version. Results: Evidence was fused from British Thoracic Society Asthma Guideline 2014, Global Initiative on Asthma 2015, and Guía Española del Manejo del Asma 2015 (2016 updates included. After 3 Delphi-rounds we developed an evidence-based document taking into account patient characteristics, including age, treatment costs and safety and best locally available medication. Conclusion: In cooperation pulmonologists, allergists, ENT physicians, paediatricians and GPs were able to develop an evidence-based document for the prevention, diagnosis and treatment of asthma and its exacerbations in Mexico.

  11. Misguided guidelines for managing labor.

    Science.gov (United States)

    Cohen, Wayne R; Friedman, Emanuel A

    2015-06-01

    In a recent review we expressed concerns about new guidelines for the assessment and management of labor recommended jointly by the American Congress of Obstetricians and Gynecologists (ACOG) and the Society for Maternal-Fetal Medicine (SMFM). These guidelines are based heavily on a new concept of how cervical dilatation and fetal descent progress, derived from the work of Zhang et al. In their Viewpoint article they have addressed, but not allayed, the concerns we described in our review. We assert that the dilatation curve promulgated by Zhang et al cannot be reconciled with direct clinical observation. Even if they were correct, however, it still does not follow that the ACOG/SMFM guidelines should recommend replacing the coherent system of identifying and managing labor aberrations described by Friedman. That system is grounded in well-established clinical principles based on decades of use and the objectively documented association of some labor abnormalities with poor fetal and maternal outcomes. Recommendations for new clinical management protocols should require the demonstration of superior outcomes through extensive, preferably prospective, assessment. Using untested guidelines for the management of labor may adversely affect women and children. Even if those guidelines were to reduce the currently excessive cesarean delivery rate, the price of that benefit is likely to be a trade-off in harm to parturients and their offspring. The nature and degree of that harm needs to be documented before considering adoption of the guidelines. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Revised DTI Guidelines for Petroleum Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, D.; Philip, L.N.

    1997-07-01

    The DTI's guidelines on petroleum measurement have been extensively revised and enlarged. The new guidelines cover a much wider scope of measurement situations than before. Included in the new issue is guidance on allocation measurement, well testing, multiphase flow measurement, new technology acceptance procedures and operating procedures for different types of measurement systems. Significant changes have taken place in recent years both in the way the oil and gas industry conducts its business and in the fiscal regime operated by the UK government. New developments in flow measurement have progressed to such an extent that they have now been adopted by the industry or are close to being adopted as beneficial methods of the measurement of hydrocarbons in whatever form they present themselves for measurement. The rapid pace of development has left the standards-making bodies behind and in some cases there is insufficient quality data to enable the standards makers to produce guidance of the generic type appropriate for national or international standards. The case-by-case approach of the DTI in approving methods of measurement lends itself better to consideration of new technology where there may be no existing standards. These, amongst other considerations, make it appropriate for the DTI to extend the scope of its guidance into these new areas. The policy developments behind the changes in the new guidelines are not static and this new document has been produced in response to an evolutionary process which is still continuing but it is right to collate and make defining statements from time to time to put on record the current status of measurement requirements for the purpose of attaining DTI approval. (author)

  13. Hypertension guidelines and their effects on the health system

    Directory of Open Access Journals (Sweden)

    Konta, Brigitte

    2005-12-01

    Full Text Available Introduction: Hypertension guidelines, which have existed for many years and primarily used in the USA, Canada and Great Britain, are now becoming an issue in Germany. Strong efforts are presently underway for a German version comparable to the guidelines developed for the mentioned countries. The development of guidelines is a part of the implementation system of guidelines in Germany. It covers the mode of operation of the AWMF (work community of the scientific medical subject companies with the clearinghouse for guidelines (CLA and the cooperation with the centre for medical quality (ÄZQ. In the HTA report the real use of the hypertension guidelines shall be investigated for Germany from the development trends and further possibilities of use according to a medical applicability. Economic issues and an optimisation of use are also discussed. Question: The following questions shall be answered in particular: 1. How much are the guidelines used concerning hypertension? 2. Can effects (or their influence be established on the medical procedures? 3. Are there statements available about costs and cost effectiveness? 4. Are there recommendations for further use? Methodology: To answer these questions, a comprehensive literature search was done. No empirical investigation was carried out. From this enquiry 206 articles were checked in detail but not all of them were available in full text. Only those publications which directly dealt with high blood pressure guidelines or articles with a direct reference to the topic have been considered in the HTA report. Publications concerning screening or methods of prevention, medical studies of the hypertension syndrome without a direct reference to guidelines and publications concerned with putting guidelines into action were excluded. Results: After an analysis of the selected literature addressing the topic of hypertension guidelines, it was evident that the use of these guidelines cannot be gathered from

  14. Spanish guideline for the definition and assessment of risk-informed inservice inspection programs for piping

    Energy Technology Data Exchange (ETDEWEB)

    Figueras, J.M.; Olivar, F.; Mendoza, C.; Vazquez, T. [CSN, Madrid (Spain); Morales, L. [UNESA, Madrid (Spain); Bros, J.; Mach, I. [Tecnatom, Madrid (Spain); Gutierrez, E. [Iberinco, Madrid (Spain)

    2001-07-01

    The recent emphasis on risk-informed in-service inspection has been taken on by the Spanish Utilities and the Spanish Regulatory Body in their proposal for a co-operation project for defining a Risk-Informed In-Service Inspection Guideline for Piping. This paper describes first the main features of this Spanish guideline and then the results of the pilot applications developed in order to check the consistency of the guideline. (authors)

  15. Spanish guideline for the definition and assessment of risk-informed inservice inspection programs for piping

    International Nuclear Information System (INIS)

    Figueras, J.M.; Olivar, F.; Mendoza, C.; Vazquez, T.; Morales, L.; Bros, J.; Mach, I.; Gutierrez, E.

    2001-01-01

    The recent emphasis on risk-informed in-service inspection has been taken on by the Spanish Utilities and the Spanish Regulatory Body in their proposal for a co-operation project for defining a Risk-Informed In-Service Inspection Guideline for Piping. This paper describes first the main features of this Spanish guideline and then the results of the pilot applications developed in order to check the consistency of the guideline. (authors)

  16. Preliminary design report for the prototypical fuel rod consolidation system

    International Nuclear Information System (INIS)

    Rosa, J.M.

    1986-01-01

    This report documents NUTECH's preliminary design of a dry, spent fuel rod consolidation system. This preliminary design is the result of Phase I of a planned four phase project. The present report on this project provides a considerable amount of detail for a preliminary design effort. The design and all of its details are described in this Preliminary Design Report (PDR). The NUTECH dry rod consolidation system described herein is remotely operated. It provides for automatic operation, but with operator hold points between key steps in the process. The operator has the ability to switch to a manual operation mode at any point in the process. The system is directed by the operator using an executive computer which controls and coordinates the operation of the in-cell equipment. The operator monitors the process using an in-cell closed circuit television (CCTV) system with audio output and equipment status displays on the computer monitor. The in-cell mechanical equipment consists of the following: (1) two overhead cranes with manipulators; (2) a multi-degree of freedom fuel handling table and its clamping equipment; (3) a fuel assembly end fitting removal station and its tools; (4) a consolidator (which pulls rods, assembles the consolidated bundle and loads the canister); (5) a canister end cap welder and weld inspection system; (6) decontamination systems; and (7) the CCTV and microphone systems

  17. Developing and implementing health and sustainability guidelines for institutional food service.

    Science.gov (United States)

    Kimmons, Joel; Jones, Sonya; McPeak, Holly H; Bowden, Brian

    2012-05-01

    Health and sustainability guidelines for institutional food service are directed at improving dietary intake and increasing the ecological benefits of the food system. The development and implementation of institutional food service guidelines, such as the Health and Human Services (HHS) and General Services Administration (GSA) Health and Sustainability Guidelines for Federal Concessions and Vending Operations (HHS/GSA Guidelines), have the potential to improve the health and sustainability of the food system. Institutional guidelines assist staff, managers, and vendors in aligning the food environment at food service venues with healthier and more sustainable choices and practices. Guideline specifics and their effective implementation depend on the size, culture, nature, and management structure of an institution and the individuals affected. They may be applied anywhere food is sold, served, or consumed. Changing institutional food service practice requires comprehensive analysis, engagement, and education of all relevant stakeholders including institutional management, members of the food supply chain, and customers. Current examples of food service guidelines presented here are the HHS and GSA Health and Sustainability Guidelines for Federal Concessions and Vending Operations, which translate evidence-based recommendations on health and sustainability into institutional food service practices and are currently being implemented at the federal level. Developing and implementing guidelines has the potential to improve long-term population health outcomes while simultaneously benefitting the food system. Nutritionists, public health practitioners, and researchers should consider working with institutions to develop, implement, and evaluate food service guidelines for health and sustainability.

  18. Developing and Implementing Health and Sustainability Guidelines for Institutional Food Service123

    Science.gov (United States)

    Kimmons, Joel; Jones, Sonya; McPeak, Holly H.; Bowden, Brian

    2012-01-01

    Health and sustainability guidelines for institutional food service are directed at improving dietary intake and increasing the ecological benefits of the food system. The development and implementation of institutional food service guidelines, such as the Health and Human Services (HHS) and General Services Administration (GSA) Health and Sustainability Guidelines for Federal Concessions and Vending Operations (HHS/GSA Guidelines), have the potential to improve the health and sustainability of the food system. Institutional guidelines assist staff, managers, and vendors in aligning the food environment at food service venues with healthier and more sustainable choices and practices. Guideline specifics and their effective implementation depend on the size, culture, nature, and management structure of an institution and the individuals affected. They may be applied anywhere food is sold, served, or consumed. Changing institutional food service practice requires comprehensive analysis, engagement, and education of all relevant stakeholders including institutional management, members of the food supply chain, and customers. Current examples of food service guidelines presented here are the HHS and GSA Health and Sustainability Guidelines for Federal Concessions and Vending Operations, which translate evidence-based recommendations on health and sustainability into institutional food service practices and are currently being implemented at the federal level. Developing and implementing guidelines has the potential to improve long-term population health outcomes while simultaneously benefitting the food system. Nutritionists, public health practitioners, and researchers should consider working with institutions to develop, implement, and evaluate food service guidelines for health and sustainability. PMID:22585909

  19. Measure Guideline. Wood Window Repair, Rehabilitation, and Replacement

    Energy Technology Data Exchange (ETDEWEB)

    Baker, P. [Building Science Corporation, Somerville, MA (United States); Eng, P. [Building Science Corporation, Somerville, MA (United States)

    2012-12-01

    This measure guideline provides information and guidance on rehabilitating, retrofitting, and replacing existing window assemblies in residential construction. The intent is to provide information regarding means and methods to improve the energy and comfort performance of existing wood window assemblies in a way that takes into consideration component durability, in-service operation, and long term performance of the strategies.

  20. Operation and monitoring guidelines and the development of a ...

    African Journals Online (AJOL)

    2009-03-31

    Mar 31, 2009 ... using the concentration and load as determined by the PHREEQC and the water balance equa- tions, and the Domenico (1987) approach (based on the advection-dispersion partial-differential equation for organic contaminant transport proc- esses in groundwater). The time span of irriga- tion, the distance ...

  1. Human Performance in Continuous Operations: Volume 1. Human Performance Guidelines

    Science.gov (United States)

    1979-12-01

    seemingly capable of enduring unusual degrees of stress and fatigue when nec- essary. When a soldier is driven by the motivation to survive, by exemplary...Vulnerabilities to degradation --Artillery 470 PS4 -?--- -. Armor Task Vulnerabilit.y The pattern of vulnurabihlties Ior tank platoon personnel (tl’Fiure 8. 2

  2. Environmental and Water Quality Operational Studies. Reservoir Shoreline Revegetation Guidelines.

    Science.gov (United States)

    1986-11-01

    24. Taller trees such as green ash, cottonwood (Populus spp.), red maple (Acer rubrum), and persimmon (Diospyros virginiana ) should be planted in...be left aboveground to prevent moisture loss due to wicking. Any excess should be pruned off. Gray and Leiser (1982) provide the following... pruning , staking woody stems, and installing fencing around individual plants or the entire site to provide protection from animals or humans. Additional

  3. Guidelines for Establishing and Operating an Adult Learning Laboratory.

    Science.gov (United States)

    Lane, Cleve W.; Lewis, Robert B.

    Presented in this volume are the results of the efforts of the staff of the Adult Learning Center of North Carolina State University to develop and validate a new concept in adult education. Intended to assist planners, teachers, graduate students and others who are faced with the task of applying educational solutions to problems of human…

  4. Operation and monitoring guidelines and the development of a ...

    African Journals Online (AJOL)

    The volumes and quality of water leaching through to the aquifers have been quantified at each site. From these data mixing ratios were calculated in order to determine the effect of the irrigation water on the underlying aquifers. One of the outcomes from this study was to define the conditions under which mine-water ...

  5. Guidelines for ground motion definition for the eastern United States

    International Nuclear Information System (INIS)

    Gwaltney, R.C.; Aramayo, G.A.; Williams, R.T.

    1985-06-01

    Guidelines for the determination of earthquake ground motion definition for the eastern United States are established here. Both far-field and near-field guidelines are given. The guidelines were based on an extensive review of the current procedures for specifying ground motion in the United States. Both empirical and theoretical procedures were used in establishing the guidelines because of the low seismicity in the eastern United States. Only a few large- to great-sized earthquakes (M/sub s/ > 7.5) have occurred in this region, no evidence of tectonic surface ruptures related to historic or Holocene earthquakes has been found, and no currently active plate boundaries of any kind are known in this region. Very little instrumented data have been gathered in the East. Theoretical procedures are proposed so that in regions of almost no data, a reasonable level of seismic ground motion activity can be assumed. The guidelines are to be used to develop the safe shutdown earthquake (SSE). A new procedure for establishing the operating basis earthquake (OBE) is proposed, in particular for the eastern United States. The OBE would be developed using a probabilistic assessment of the geological conditions and the recurrence of seismic events at a site. These guidelines should be useful in development of seismic design requirements for future reactors. 17 refs., figs., tabs

  6. Draft revision of human factors guideline HF-010

    International Nuclear Information System (INIS)

    Lee, Hyun Chul; Lee, Yong Hee; Oh, In Seok; Lee, Jung Woon; Cha, Woo Chang; Lee, Dhong Ha

    2003-05-01

    The Application of Human Factors to the design of Man-Machine Interfaces System(MMIS) in the nuclear power plant is essential to the safety and productivity of the nuclear power plants, human factors standards and guidelines as well as human factors analysis methods and experiments are weightily used to the design application. A Korean engineering company has developed a human factors engineering guideline, so-call HF-010, and has used it for human factors design, however the revision of HF-010 is necessary owing to lack of the contents related to the advanced MMI(Man-Machine Interfaces). As the results of the reviews of HF-010, it is found out that the revision of Section 9. Computer Displays of HF-010 is urgent, thus the revision was drafted on the basis of integrated human factors design guidelines for VDT, human factors design guidelines for PMAS SPADES display, human factors design guidelines for PMAS alarm display, and human factors design guidelines for electronic displays developed by the surveillance and operation support project of KOICS. The draft revision of HF-010 Section 9 proposed in this report can be utilized for the human factors design of the advanced MMI, and the high practical usability of the draft can be kept up through the continuous revision according to the advancement of digital technology

  7. Guideline for Bayesian Net based Software Fault Estimation Method for Reactor Protection System

    International Nuclear Information System (INIS)

    Eom, Heung Seop; Park, Gee Yong; Jang, Seung Cheol

    2011-01-01

    The purpose of this paper is to provide a preliminary guideline for the estimation of software faults in a safety-critical software, for example, reactor protection system's software. As the fault estimation method is based on Bayesian Net which intensively uses subjective probability and informal data, it is necessary to define formal procedure of the method to minimize the variability of the results. The guideline describes assumptions, limitations and uncertainties, and the product of the fault estimation method. The procedure for conducting a software fault-estimation method is then outlined, highlighting the major tasks involved. The contents of the guideline are based on our own experience and a review of research guidelines developed for a PSA

  8. Process control guidelines for CY 70 thorium campaign

    International Nuclear Information System (INIS)

    Jackson, R.R.

    1970-01-01

    The report comprises five parts, with part I being an introduction. Part II consists of a general treatment of process control methods. Parts III through V discuss, in the flowsheet sequence, those problems pertinent to each equipment piece or system and provide operating guidelines. Specific operations that are somewhat different from those normally encountered in Purex are discussed at length. Operations routine to Purex can be found in the pertinent standard operating procedures. Part VI describes in general terms the sequence to be followed in initiating and completing a variety of transient conditions

  9. Guidelines for Authors

    Directory of Open Access Journals (Sweden)

    Abdullah Demir

    2016-06-01

    Full Text Available Guidelines for Authors cumhuriyet theology journal  reguires writers to use the The Chicago Manual of Style “notes and bibliography” system of referencing.First citation: author(s first name and last name, title, (if applicable first and last name of translator or editor, place of publication, publisher, date of publication, page number.Subsequent citations: author’s last name, the short title, and the page number should be indicated in all subsequent citations. Footnote citations should conform to the following examples.References: References should be placed at the end of the text in alphabetical order. If a source has more than one author, the surname and name of the first author should be written, and the other authors should be indicated by et.al. The titles of books and journals should be italicized; article titles and book chapters should be placed in quotation marks. Translator’s and editor’s names (if there are any should follow the title of the work: BOOKa One Author: 
1. Michael Pollan, The Omnivore’s Dilemma: A Natural History of Four Meals (New York: Penguin, 2006, 99–100.2. Pollan, Omnivore’s Dilemma, 3.Bibliography: Pollan, Michael. The Omnivore’s Dilemma: A Natural History of Four Meals. New York: Penguin, 2006.  b Two Authors1. Geoffrey C. Ward and Ken Burns, The War: An Intimate History 1941–1945 (New York: Knopf, 2007, 52.2. Ward and Burns, War, 59–61. Bibliography: Ward, Geoffrey C., and Ken Burns. The War: An Intimate History 1941–1945. New York: Knopf, 2007.c Three or More Authors
For three or more authors, list all of the authors in the bibliography; in the note, list only the first author, followed by et al. (“and others”:1. Mitchell L. Eisen, Jodi A. Quas, and Gail S. Goodman, eds., Memory and Suggestibility in the Forensic Interview (Mahwah, NJ: L. Erlbaum Assoicates, 2002, 65.2. Eisen and et al., Memory and Suggestibility in the Forensic Interview, 67.Bibliography: Eisen, Mitchell

  10. NDMA guidelines on management of nuclear and radiological emergencies

    International Nuclear Information System (INIS)

    Abani, M.C.

    2011-01-01

    The National Disaster Management Authority (NDMA), ever since it's formation as an apex policy making body for the country in the field of disaster management, has formulated a set of guidelines to assist the various ministries, states and stakeholders in preparing their plans to handle different types of disasters. The guidelines on management of nuclear and radiological emergencies assume great importance in the present context, as our country has very ambitious programme to exploit nuclear energy for peaceful uses. Though, we have an enviable and impeccable record of safety and virtually fail-safe operations in all our nuclear establishments, the possibility, however, remote it may be, of human error, systems failure, sabotage, earthquake, floods, terrorist attacks etc leading to the release of radioactive material in the public domain, cannot be entirely ruled out. With this view, it was decided to prepare the national guidelines by NDMA to manage any nuclear/radiological emergency in public domain. Through these guidelines, we aim to further strengthen our existing nuclear/radiological emergency management framework and generate public awareness, which will go a long way in allaying misapprehensions, if any, amongst the public about the country's nuclear programme. Like in all our guidelines for handling of different types of the disasters, in these Guidelines also, maximum emphasis has been laid on the prevention of nuclear and radiological emergencies, along with a detailed consideration of all other elements of the disaster management continuum. The national guidelines have been prepared and a consensus was arrived on various issues, after widespread consultations and elaborates discussions amongst experts as well as stakeholders. It is assumed that once these guidelines are implemented by the stakeholders and converted into action plans followed by SOPs that will further reduce the chances of accidents in the nuclear arena. (author)

  11. 7 CFR 622.5 - Guidelines.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Guidelines. 622.5 Section 622.5 Agriculture... AGRICULTURE WATER RESOURCES WATERSHED PROJECTS General § 622.5 Guidelines. Guidelines for carrying out... Environmental Principles and Guidelines for Water and Related Land Resources Implementation Studies issued by...

  12. 36 CFR 910.67 - Square guidelines.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Square guidelines. 910.67... GUIDELINES AND UNIFORM STANDARDS FOR URBAN PLANNING AND DESIGN OF DEVELOPMENT WITHIN THE PENNSYLVANIA AVENUE DEVELOPMENT AREA Glossary of Terms § 910.67 Square guidelines. Square Guidelines establish the Corporation's...

  13. 28 CFR 42.306 - Guidelines.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Guidelines. 42.306 Section 42.306... PROCEDURES Equal Employment Opportunity Program Guidelines § 42.306 Guidelines. (a) Recipient agencies are... guidelines under their equal employment opportunity program which will correct, in a timely manner, any...

  14. 28 CFR 2.36 - Rescission guidelines.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Rescission guidelines. 2.36 Section 2.36... guidelines. (a) The following guidelines shall apply to the sanctioning of disciplinary infractions or new... such period of confinement has resulted from initial parole to a detainer). These guidelines specify...

  15. 28 CFR 42.404 - Guidelines.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Guidelines. 42.404 Section 42.404... Guidelines. (a) Federal agencies shall publish title VI guidelines for each type of program to which they extend financial assistance, where such guidelines would be appropriate to provide detailed information...

  16. 36 CFR 1191.1 - Accessibility guidelines.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Accessibility guidelines... COMPLIANCE BOARD AMERICANS WITH DISABILITIES ACT (ADA) ACCESSIBILITY GUIDELINES FOR BUILDINGS AND FACILITIES; ARCHITECTURAL BARRIERS ACT (ABA) ACCESSIBILITY GUIDELINES § 1191.1 Accessibility guidelines. (a) The...

  17. Raising the Bar with Trades Staffing Guidelines.

    Science.gov (United States)

    Weidner, Theodore J.

    2000-01-01

    Examines the APPA's Trades Staffing Guidelines Task Force for college campus building maintenance and presents descriptions of the proposed guideline levels and a matrix of indicators for the Trades Staffing Guidelines. The levels and matrix are intended to mimic features of the custodial staffing guidelines. (GR)

  18. 78 FR 38102 - Passenger Vessels Accessibility Guidelines

    Science.gov (United States)

    2013-06-25

    ... Costs and Benefits The primary estimates of the costs and benefits of the proposed guidelines are shown... quantify the benefits of the proposed guidelines due to the nature of the benefits. The proposed guidelines..., transportation, public accommodation, and leisure. The proposed guidelines would enable these individuals to...

  19. Revised dietary guidelines for Koreans.

    Science.gov (United States)

    Jang, Young Ai; Lee, Haeng Shin; Kim, Bok Hee; Lee, Yoonna; Lee, Hae Jeung; Moon, Jae Jin; Kim, Cho-il

    2008-01-01

    With rapidly changing dietary environment, dietary guidelines for Koreans were revised and relevant action guides were developed. First, the Dietary Guidelines Advisory Committee was established with experts and government officials from the fields of nutrition, preventive medicine, health promotion, agriculture, education and environment. The Committee set dietary goals for Koreans aiming for a better nutrition state of all after a thorough review and analysis of recent information related to nutritional status and/or problems of Korean population, changes in food production/supply, disease pattern, health policy and agricultural policy. Then, the revised dietary guidelines were proposed to accomplish these goals in addition to 6 different sets of dietary action guides to accommodate specific nutrition and health problems of respective age groups. Subsequently, these guidelines and guides were subjected to the focus group review, consumer perception surveys, and a public hearing for general and professional comments. Lastly, the language was clarified in terms of public understanding and phraseology. The revised Dietary guidelines for Koreans are as follows: eat a variety of grains, vegetables, fruits, fish, meat, poultry and dairy products; choose salt-preserved foods less, and use less salt when you prepare foods; increase physical activity for a healthy weight, and balance what you eat with your activity; enjoy every meal, and do not skip breakfast; if you drink alcoholic beverages, do so in moderation; prepare foods properly, and order sensible amounts; enjoy our rice-based diet.

  20. UVISS preliminary visibility analysis

    DEFF Research Database (Denmark)

    Betto, Maurizio

    1998-01-01

    The goal of this work is to obtain a preliminary assessment of the sky visibility for anastronomical telescope located on the express pallet of the International SpaceStation (ISS)} taking into account the major constraints imposed on the instrument by the ISSattitude and structure. Part of the w......The goal of this work is to obtain a preliminary assessment of the sky visibility for anastronomical telescope located on the express pallet of the International SpaceStation (ISS)} taking into account the major constraints imposed on the instrument by the ISSattitude and structure. Part...... of the work is also to setup the kernel of a software tool for the visibility analysis thatshould be easily expandable to consider more complex strucures for future activities.This analysis is part of the UVISS assessment study and it is meant to provide elementsfor the definition and the selection...