WorldWideScience

Sample records for preliminary operational guidelines

  1. Preliminary report on operational guidelines developed for use in emergency preparedness and response to a radiological dispersal device incident.

    Energy Technology Data Exchange (ETDEWEB)

    Yu, C.; Cheng, J.-J.; Kamboj, S.; Domotor, S.; Wallo, A.; Environmental Science Division; DOE

    2006-12-15

    This report presents preliminary operational guidelines and supporting work products developed through the interagency Operational Guidelines Task Group (OGT). The report consolidates preliminary operational guidelines, all ancillary work products, and a companion software tool that facilitates their implementation into one reference source document. The report is intended for interim use and comment and provides the foundation for fostering future reviews of the operational guidelines and their implementation within emergency preparedness and response initiatives in the event of a radiological dispersal device (RDD) incident. The report principally focuses on the technical derivation and presentation of the operational guidelines. End-user guidance providing more details on how to apply these operational guidelines within planning and response settings is being considered and developed elsewhere. The preliminary operational guidelines are categorized into seven groups on the basis of their intended application within early, intermediate, and long-term recovery phases of emergency response. We anticipate that these operational guidelines will be updated and refined by interested government agencies in response to comments and lessons learned from their review, consideration, and trial application. This review, comment, and trial application process will facilitate the selection of a final set of operational guidelines that may be more or less inclusive of the preliminary operational guidelines presented in this report. These and updated versions of the operational guidelines will be made available through the OGT public Web site (http://ogcms.energy.gov) as they become finalized for public distribution and comment.

  2. 50 CFR 253.18 - Program operating guidelines.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Program operating guidelines. 253.18 Section 253.18 Wildlife and Fisheries NATIONAL MARINE FISHERIES SERVICE, NATIONAL OCEANIC AND ATMOSPHERIC... Guarantee Program § 253.18 Program operating guidelines. The Division may issue Program operating guidelines...

  3. Main-coolant-pump shaft-seal guidelines. Volume 2. Operational guidelines. Final report

    International Nuclear Information System (INIS)

    Fair, C.E.; Greer, A.O.

    1983-03-01

    This report presents a set of guidelines and criteria for improving main coolant pump shaft seal operational reliability. The noted guidelines are developed from EPRI sponsored nuclear power plant seal operating experience studies. Usage procedures/practices and operational environment influence on seal life and reliability from the most recent such survey are summarized. The shaft seal and its auxiliary supporting systems are discussed both from technical and operational related viewpoints

  4. Criteria for safety-related nuclear plant operator actions: a preliminary assessment of available data

    International Nuclear Information System (INIS)

    Haas, P.M.; Bott, T.F.

    1980-01-01

    In the US, an effort has been underway for a number of years to develop a design standard to define when required manual operator action can be accepted as part of a nuclear plant design basis. Insufficient data are available to provide quantitative guidelines for the standard. To provide the necessary data base to support such standards and the necessary quantitative assessment of operator reliability, the US Nuclear Regulatory Commission is sponsoring a study at Oak National Laboratory to develop the data base. A preliminary assessment completed in April, 1979 concluded that sufficient data from US operating experience did not exist to provide an adequate data base. A program of research using full-scope nuclear plant simulators and results that are correlated to field data was suggested. That program was recently initiated. The approach, results and conclusions of the preliminary assessment are reviewed and the planned research program of simulator studies is summarised. (author)

  5. Main-coolant-pump shaft-seal guidelines. Volume 3. Specification guidelines. Final report

    International Nuclear Information System (INIS)

    Fair, C.E.; Greer, A.O.

    1983-03-01

    This report presents a set of guidelines and criteria to aid in the generation of procurement specifications for Main Coolant Pump Shaft Seals. The noted guidelines are developed from EPRI sponsored nuclear power plant seal operating experience studies, a review of pump and shaft seal literature and discussions with pump and seal designers. This report is preliminary in nature and could be expanded and finalized subsequent to completion of further design, test and evaluation efforts

  6. Influence of Planetary Protection Guidelines on Waste Management Operations

    Science.gov (United States)

    Hogan, John A.; Fisher, John W.; Levri, Julie A.; Wignarajah, Kanapathipi; Race, Margaret S.; Stabekis, Perry D.; Rummel, John D.

    2005-01-01

    Newly outlined missions in the Space Exploration Initiative include extended human habitation on Mars. During these missions, large amounts of waste materials will be generated in solid, liquid and gaseous form. Returning these wastes to Earth will be extremely costly, and will therefore likely remain on Mars. Untreated, these wastes are a reservoir of live/dead organisms and molecules considered to be "biomarkers" i.e., indicators of life). If released to the planetary surface, these materials can potentially confound exobiology experiments and disrupt Martian ecology indefinitely (if existent). Waste management systems must therefore be specifically designed to control release of problematic materials both during the active phase of the mission, and for any specified post-mission duration. To effectively develop waste management requirements for Mars missions, planetary protection guidelines must first be established. While previous policies for Apollo lunar missions exist, it is anticipated that the increased probability of finding evidence of life on Mars, as well as the lengthy mission durations will initially lead to more conservative planetary protection measures. To facilitate the development of overall requirements for both waste management and planetary protection for future missions, a workshop was conducted to identify how these two areas interface, and to establish a preliminary set of planetary protection guidelines that address waste management operations. This paper provides background regarding past and current planetary protection and waste management issues, and their interactions. A summary of the recommended planetary protection guidelines, anticipated ramifications and research needs for waste management system design for both forward (Mars) and backward (Earth) contamination is also provided.

  7. General Guidelines for Remote Operation and Maintenance of Pyroprocess Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S. H.; Park, B. S.; Park, H. S.; Lee, H. J.; Choi, C. W.; Lee, J. K

    2007-12-15

    As the pyroprocess handle the high radioactive materials, a high radioactive material handling facility required high safety, radioactive shielding, strict quality control, and the remote handling equipment of high technology. This report describes the guidelines of for pyroprocess based the design guides for radioactive material handling facility and equipment from American Nuclear Society(ANS), design guidelines for remotely maintained equipment from Oak Ridge National Laboratory(ORNL), and the experience of design for ACP equipment installed at the ACPF(Advanced Conditioning Process Facility). The General guidelines in this report are as follows. The General guidelines for remote operation and maintenance of pyroprocess equipment: Pyroprocess, Remote handling equipment for pyroprocess, General guide for remote operation and maintenance, general guidelines for the design of remotely operated and maintained equipment, Estimation and analysis for remote maintenance.

  8. No. 148-Guidelines for Operative Vaginal Birth.

    Science.gov (United States)

    Cargill, Yvonne M; MacKinnon, Catherine Jane

    2018-02-01

    To provide guidelines for operative vaginal birth in the management of the second stage of labour. Non-operative techniques, episiotomy, and Caesarean section are compared to operative vaginal birth. Reduced fetal and maternal morbidity and mortality. MEDLINE and Cochrane databases were searched using the key words ''vacuum" and "birth" as well as "forceps" and "birth" for literature published in English from january 1970 to June 2004. The level of evidence and quality of rec-ommendations made are described using the Evaluation of Evidence from the Canadian Task Force on the Periodic Health Examination. VALIDATION: The Clinical Practice Obstetrics Committee and Executive and Council of the Society of Obstetricians and Gynaecologists of Canada approved these guidelines. Copyright © 2018. Published by Elsevier Inc.

  9. The European Stroke Organisation Guidelines: a standard operating procedure.

    Science.gov (United States)

    Ntaios, George; Bornstein, Natan M; Caso, Valeria; Christensen, Hanne; De Keyser, Jacques; Diener, Hans-Christoph; Diez-Tejedor, Exuperio; Ferro, Jose M; Ford, Gary A; Grau, Armin; Keller, Emanuella; Leys, Didier; Russell, David; Toni, Danilo; Turc, Guillaume; Van der Worp, Bart; Wahlgren, Nils; Steiner, Thorsten

    2015-10-01

    In 2008, the recently founded European Stroke Organisation published its guidelines for the management of ischemic stroke and transient ischemic attack. This highly cited document was translated in several languages and was updated in 2009. Since then, the European Stroke Organisation has published guidelines for the management of intracranial aneurysms and subarachnoidal hemorrhage, for the establishment of stroke units and stroke centers, and recently for the management of intracerebral hemorrhage. In recent years, the methodology for the development of guidelines has evolved significantly. To keep pace with this progress and driven by the strong determination of the European Stroke Organisation to further promote stroke management, education, and research, the European Stroke Organisation decided to delineate a detailed standard operating procedure for its guidelines. There are two important cornerstones in this standard operating procedure: The first is the implementation of the Grading of Recommendations Assessment, Development, and Evaluation methodology for the development of its Guideline Documents. The second one is the decision of the European Stroke Organisation to move from the classical model of a single Guideline Document about a major topic (e.g. management of ischemic stroke) to focused modules (i.e. subdivisions of a major topic). This will enable the European Stroke Organisation to react faster when new developments in a specific stroke field occur and update its recommendations on the related module rather swiftly; with the previous approach of a single large Guideline Document, its entire revision had to be completed before an updated publication, delaying the production of up-to-date guidelines. After discussion within the European Stroke Organisation Guidelines Committee and significant input from European Stroke Organisation members as well as methodologists and analysts, this document presents the official standard operating procedure for

  10. The European Stroke Organisation Guidelines: a standard operating procedure

    DEFF Research Database (Denmark)

    Ntaios, George; Bornstein, Natan M; Caso, Valeria

    2015-01-01

    pace with this progress and driven by the strong determination of the European Stroke Organisation to further promote stroke management, education, and research, the European Stroke Organisation decided to delineate a detailed standard operating procedure for its guidelines. There are two important...... cornerstones in this standard operating procedure: The first is the implementation of the Grading of Recommendations Assessment, Development, and Evaluation methodology for the development of its Guideline Documents. The second one is the decision of the European Stroke Organisation to move from the classical...... and significant input from European Stroke Organisation members as well as methodologists and analysts, this document presents the official standard operating procedure for the development of the Guideline Documents of the European Stroke Organisation....

  11. Emergency operating procedures guidelines for pressurized water reactors - a progress report

    International Nuclear Information System (INIS)

    Lyon, W.C.

    1984-01-01

    Emergency Operating Procedures (EOPs) contain the instructions the operator will follow to control a nuclear plant whenever a condition exists that potentially jeopardizes the fuel cladding, the reactor coolant system (RCS) pressure boundary, or the containment. The EOPs are prepared from guidelines which contain the major operator instructions that will be in the EOPs. Guidelines have been prepared by owners' groups having Babcock and Wilcox (BandW), Combustion Engineering (CE), General Electric (GE), and Westinghouse (W) plants. These guidelines cover many aspects of full power operation. Future effort is anticipated to complete coverage of transient events, including severe accidents, all power conditions, and shutdown. This paper describes the philosophy which has guided NRC technical review of guidelines, progress achieved in providing comprehensive coverage of emergency conditions for PWRs, and anticipated future technical activities

  12. Guideline for the preparation of safe operating procedures

    International Nuclear Information System (INIS)

    Stinnett, L.; Carroll, M.M.; Crooks, D.L.; Doyle, J.R.; Jeblick, H.G.; Kessel, D.S.; Tippy, M.W.; Stuckey, J.M.

    1981-03-01

    These procedures are written for activities that involve the use of explosives, dangerous chemicals, radioactive materials, hazardous sytems, and for certain types of operational facilities which present hazards. This guideline presents a suggested Safe Operating Procedures format

  13. Guideline for the preparation of safe operating procedures

    International Nuclear Information System (INIS)

    Stinnett, L.; Armbrust, E.F.; Christy, V.W.; Doyle, J.R.; Kesinger, J.H.

    1977-03-01

    Sandia Laboratories Safe Operating Procedures (SOP) are written for activities which involve the use of explosives, dangerous chemicals, radioactive materials, hazardous systems, and certain types of operational facilities which present hazards. This guideline presents a suggested SOP format

  14. Guidelines for the design and operation of makeup water treatment systems

    International Nuclear Information System (INIS)

    Lee, Y.H.; Planek, M.A.; Sopocy, D.M.; Tomaga, C.M.; Abrams, I.M.; Anderson, C.C.; Balazs, M.K.; Houskava, J.; Williams, R.

    1989-06-01

    These guidelines present the industry with a standardized program to ensure the optimum design and operation of their individual makeup water treatment systems. These guidelines present, in a non-technical and non-proprietary format, the makeup water treatment system design and operating topics that are discussed in detail in Volumes 1 and 2 of NP-6377-SL. The individual guidelines contained in Volumes 1 and 2 are presented as separate imperative statements, followed by a technical justification discussion, which provides further explanations. In addition and when applicable, the guidelines relate pertinent operational in regard to monitoring parameters for operation, alternative actions, troubleshooting, management responsibilities and shutdown practices. Design considerations are also addressed, when applicable, in regard to equipment cost and advantages and disadvantages for the design recommendations. Appendices provide background information for performance criteria, component description, economic evaluation procedures and definitions. 4 refs

  15. Preliminary Guideline for the High Temperature Structure Integrity Assessment Procedure Part II. High Temperature Structural Integrity Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Han; Kim, J. B.; Lee, H. Y.; Park, C. G.; Joo, Y. S.; Koo, G. H.; Kim, S. H

    2007-02-15

    A high temperature structural integrity assessment belongs to the Part II of a whole preliminary guideline for the high temperature structure. The main contents of this guideline are the evaluation procedures of the creep-fatigue crack initiation and growth in high temperature condition, the high temperature LBB evaluation procedure, and the inelastic evaluations of the welded joints in SFR structures. The methodologies for the proper inelastic analysis of an SFR structures in high temperatures are explained and the guidelines of inelastic analysis options using ANSYS and ABAQUS are suggested. In addition, user guidelines for the developed NONSTA code are included. This guidelines need to be continuously revised to improve the applicability to the design and analysis of the SFR structures.

  16. BWR water chemistry guidelines and PWR primary water chemistry guidelines in Japan – Purpose and technical background

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, Hirotaka, E-mail: kawamuh@criepi.denken.or.jp [Central Research Institute of Electric Power Industry (Japan); Hirano, Hideo [Central Research Institute of Electric Power Industry (Japan); Katsumura, Yousuke [University of Tokyo (Japan); Uchida, Shunsuke [Tohoku University (Japan); Mizuno, Takayuki [Mie University (Japan); Kitajima, Hideaki; Tsuzuki, Yasuo [Japan Nuclear Safety Institute (Japan); Terachi, Takumi [Institute of Nuclear Safety System, Inc. (Japan); Nagase, Makoto; Usui, Naoshi [Hitachi-GE Nuclear Energy, Ltd. (Japan); Takagi, Junichi; Urata, Hidehiro [Toshiba Corporation (Japan); Shoda, Yasuhiko; Nishimura, Takao [Mitsubishi Heavy Industry, Ltd. (Japan)

    2016-12-01

    Highlights: • Framework of BWR/PWR water chemistry Guidelines in Japan are presented. • Guideline necessity, definitions, philosophy and technical background are mentioned. • Some guideline settings for control parameters and recommendations are explaines. • Chemistry strategy is also mentioned. - Abstract: After 40 years of light water reactor (LWR) operations in Japan, the sustainable development of water chemistry technologies has aimed to ensure the highest coolant system component integrity and fuel reliability performance for maintaining LWRs in the world; additionally, it aimed to achieve an excellent dose rate reduction. Although reasonable control and diagnostic parameters are utilized by each boiling water reactor (BWR) and pressurized water reactor (PWR) owner, it is recognized that specific values are not shared among everyone involved. To ensure the reliability of BWR and PWR operation and maintenance, relevant members of the Atomic Energy Society of Japan (AESJ) decided to establish guidelines for water chemistry. The Japanese BWR and PWR water chemistry guidelines provide strategies to improve material and fuel reliability performance as well as to reduce dosing rates. The guidelines also provide reasonable “control values”, “diagnostic values” and “action levels” for multiple parameters, and they stipulate responses when these levels are exceeded. Specifically, “conditioning parameters” are adopted in the Japanese PWR primary water chemistry guidelines. Good practices for operational conditions are also discussed with reference to long-term experience. This paper presents the purpose, technical background and framework of the preliminary water chemistry guidelines for Japanese BWRs and PWRs. It is expected that the guidelines will be helpful as an introduction to achieve safety and reliability during operations.

  17. Operating cost guidelines for benchmarking DOE thermal treatment systems for low-level mixed waste

    International Nuclear Information System (INIS)

    Salmon, R.; Loghry, S.L.; Hermes, W.H.

    1994-11-01

    This report presents guidelines for estimating operating costs for use in benchmarking US Department of Energy (DOE) low-level mixed waste thermal treatment systems. The guidelines are based on operating cost experience at the DOE Toxic Substances Control Act (TSCA) mixed waste incinerator at the K-25 Site at Oak Ridge. In presenting these guidelines, it should be made clear at the outset that it is not the intention of this report to present operating cost estimates for new technologies, but only guidelines for estimating such costs

  18. Simplified methods and application to preliminary design of piping for elevated temperature service

    International Nuclear Information System (INIS)

    Severud, L.K.

    1975-01-01

    A number of simplified stress analysis methods and procedures that have been used on the FFTF project for preliminary design of piping operating at elevated temperatures are described. The rationale and considerations involved in developing the procedures and preliminary design guidelines are given. Applications of the simplified methods to a few FFTF pipelines are described and the success of these guidelines are measured by means of comparisons to pipeline designs that have had detailed Code type stress analyses. (U.S.)

  19. Standing operating procedures for developing acute exposure guideline levels for hazardous chemicals

    National Research Council Canada - National Science Library

    National Research Council (U.S.). Subcommittee on Acute Exposure Guideline Levels

    2001-01-01

    Standing Operating Procedures for Developing Acute Exposure Guideline Levels for Hazardous Chemicals contains a detailed and comprehensive methodology for developing acute exposure guideline levels (AEGLs...

  20. Improving operation notes to meet British Orthopaedic Association guidelines.

    Science.gov (United States)

    Morgan, David; Fisher, Noel; Ahmad, Aman; Alam, Fazle

    2009-04-01

    Operation notes are an important part of medical records for clinical, academic and medicolegal reasons. This study audited the quality of operative note keeping for total knee replacements against the standards set by the British Orthopaedic Association (BOA). A prospective review of all patients undergoing total knee replacement at a district general hospital over 8 months. Data recorded were compared with those required by the BOA good-practice guidelines. Change in practice was implemented and the audit cycle completed. Data were statistically analysed. A total of 129 operation notes were reviewed. There was a significant improvement in the mean number of data points recorded from 9.6 to 13.1. The least well recorded data were diagnosis, description of findings, alignment and postoperative flexion range. All had a significant improvement except description of findings. The operating surgeon writing the note improved from 56% to 67%. Detailed postoperative instructions also improved in quality. Surgeon education and the use of a checklist produce better quality total knee replacement operation notes in line with BOA guidelines. Further improvements may be made by making the data points part of the operation note itself.

  1. National synchrotron light source guidelines for the conduct of operations

    International Nuclear Information System (INIS)

    Buckley, M.

    1998-01-01

    To improve the quality and uniformity of operations at the Department of Energy's facilities, the DOE issued Order 5480.19 ''Conduct of Operations Requirements at DOE facilities.'' This order recognizes that the success of a facility's mission critically depends upon a high level of performance by its personnel and equipment. This performance can be severely impaired if the facility's Conduct of Operations pays inadequate attention to issues of organization, safety, health, and the environment. These guidelines are Brookhaven National Laboratory's and the National Synchrotron Light Source's acknowledgement of the principles of Conduct of Operations and the response to DOE Order 5480.19. These guidelines cover the following areas: (1) operations organization and administration; (2) shift routines and operating practices; (3) control area activities; (4) communications; (5) control of on-shift training; (6) investigation of abnormal events; (7) notifications; (8) control of equipment and system studies; (9) lockouts and tagouts; (10) independent verification; (11) log-keeping; (12) operations turnover; (13) operations aspects of facility process control (14) required reading; (15) timely orders to operators; (16) operations procedures; (17) operator aid posting; and (18) equipment sizing and labeling

  2. Dam safety operating guidelines

    International Nuclear Information System (INIS)

    Elsayed, E.; Leung, T.; Kirkham, A.; Lum, D.

    1990-01-01

    As part of Ontario Hydro's dam structure assessment program, the hydraulic design review of several river systems has revealed that many existing dam sites, under current operating procedures, would not have sufficient discharge capacity to pass the Inflow Design Flood (IDF) without compromising the integrity of the associated structures. Typical mitigative measures usually considered in dealing with these dam sites include structural alterations, emergency action plans and/or special operating procedures designed for extreme floods. A pilot study was carried out for the Madawaska River system in eastern Ontario, which has seven Ontario Hydro dam sites in series, to develop and evaluate the effectiveness of the Dam Safety Operating Guidelines (DSOG). The DSOG consist of two components: the flood routing schedules and the minimum discharge schedules, the former of which would apply in the case of severe spring flood conditions when the maximum observed snowpack water content and the forecast rainfall depth exceed threshold values. The flood routing schedules would identify to the operator the optimal timing and/or extent of utilizing the discharge facilities at each dam site to minimize the potential for dam failures cased by overtopping anywhere in the system. It was found that the DSOG reduced the number of structures overtopped during probable maximum flood from thirteen to four, while the number of structures that could fail would be reduced from seven to two. 8 refs., 4 figs., 3 tabs

  3. Managing materiality: a preliminary examination of the adoption of the new GRI G4 guidelines on materiality within the business community

    OpenAIRE

    Jones, Peter; Comfort, Daphne; Hillier, David

    2016-01-01

    The concept of materiality emerged as the most important element in the new G4 guideline on corporate sustainability reporting launched by the Global Reporting Initiative (GRI) in 2013. This commentary paper offers a preliminary examination of the way in which these new guidelines are being adopted within the business community. The paper begins with a short discussion of the GRI guidelines and the enhanced emphasis on materiality, and the paper draws its empirical material from the first 10 ...

  4. Standard operating procedures for ESPEN guidelines and consensus papers.

    Science.gov (United States)

    Bischoff, Stephan C; Singer, Pierre; Koller, Michael; Barazzoni, Rocco; Cederholm, Tommy; van Gossum, André

    2015-12-01

    The ESPEN Guideline standard operating procedures (SOP) is based on the methodology provided by the Association of Scientific Medical Societies of Germany (AWMF), the Scottish Intercollegiate Guidelines Network (SIGN), and the Centre for Evidence-based Medicine at the University of Oxford. The SOP is valid and obligatory for all future ESPEN-sponsored guideline projects aiming to generate high-quality guidelines on a regular basis. The SOP aims to facilitate the preparation of guideline projects, to streamline the consensus process, to ensure quality and transparency, and to facilitate the dissemination and publication of ESPEN guidelines. To achieve this goal, the ESPEN Guidelines Editorial board (GEB) has been established headed by two chairmen. The GEB will support and supervise the guideline processes and is responsible for the strategic planning of ESPEN guideline activities. Key elements of the SOP are the generation of well-built clinical questions according to the PICO system, a systemic literature search, a classification of the selected literature according to the SIGN evidence levels providing an evidence table, and a clear and straight-forward consensus procedure consisting of online voting's and a consensus conference. Only experts who meet the obligation to disclosure any potential conflict of interests and who are not employed by the Industry can participate in the guideline process. All recommendations will be graded according to the SIGN grading and novel outcome models besides biomedical endpoints. This approach will further extent the leadership of ESPEN in creating up-to-date and suitable for implementation guidelines and in sharing knowledge on malnutrition and clinical nutrition. Copyright © 2015 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  5. 76 FR 63628 - Preliminary Damage Assessment for Individual Assistance Operations Manual (9327.2-PR)

    Science.gov (United States)

    2011-10-13

    ...] Preliminary Damage Assessment for Individual Assistance Operations Manual (9327.2-PR) AGENCY: Federal... Individual Assistance Operations Manual (9327.2-PR). DATES: Comments must be received by November 14, 2011... of the draft Preliminary Damage Assessment for Individual Assistance Operations Manual (9327.2-PR) on...

  6. Operability Guidelines For Product Tanker In Heavy Weather In The Adriatic Sea

    Directory of Open Access Journals (Sweden)

    Mudronja Luka

    2014-06-01

    Full Text Available This paper presents operability guidelines for seafarers on a product tanker which navigates in the Adriatic Sea during heavy weather. Tanker route starts from the Otranto strait in the south to the island Krk in the north of Adriatic Sea. Heavy weather is caused by south wind called jugo (blowing from E-SE to SS-E, sirocco family. Operability guidelines are given based on an operability criteria platform for presenting ship seakeeping characteristics. Operability criteria considered in this paper are propeller emergence, deck wetness and bow acceleration of a product tanker. Limiting values of mentioned criteria determine sustainable speed. Heavy weather is described by extreme sea state of 7.5 m wave height. Wave spectrum used in this paper is Tabain spectrum which is developed specifically for Adriatic Sea. Seafarer's approach of decisions making in extreme weather is also shown and servers as a guideline for further research of the authors.

  7. SALTO Peer Review Guidelines. Guidelines for Peer Review of Safety Aspects of Long Term Operation of Nuclear Power Plants

    International Nuclear Information System (INIS)

    2014-01-01

    International peer review is a useful tool for Member States to exchange experiences, learn from each other and apply good practices in the long term operation (LTO) of nuclear power plants (NPPs). The peer review is also an important mechanism through which the IAEA supports Member States in enhancing the safety of NPPs. The IAEA has conducted various types of safety review that indirectly address aspects of LTO, including safety reviews for design, engineering, operation and external hazards. Operational Safety Review Team (OSART) services include review of ageing management programmes. In addition, several Member States have requested Ageing Management Assessment Team (AMAT) missions. Through these experiences, it was recognized that a comprehensive peer review on LTO would be very useful to Member States. The Safety Aspects of Long Term Operation (SALTO) peer review addresses strategy and key elements for the safe LTO of NPPs, which includes AMAT objectives and complements OSART reviews. The SALTO peer review is designed to assist operating organizations in adopting a proper approach to LTP including implementing appropriate activities to ensure that plant safety will be maintained during the LTO period. The SALTO peer review can be tailored to focus on ageing management programmes (AMPs) or on other activities related to LTO to support the Member State in enhancing the safety of its NPPs. The SALTO peer review can also support regulators in establishing or improving regulatory and licensing strategies for the LTO of NPPs. The guidelines in this publication are primarily intended for members of a SALTO review team and provide a basic structure and common reference for peer reviews of LTO. Additionally, the guidelines also provide useful information to the operating organizations of NPPs (or technical support organizations) for carrying out their own self-assessments or comprehensive programme reviews. The guidelines are intended to be generic, as there are

  8. A Value Function Approach to Information Operations MOE's: A Preliminary Study

    National Research Council Canada - National Science Library

    Doyle, Michael

    1997-01-01

    A value focused thinking approach is applied to information operations. A preliminary value hierarchy for information operations is constructed by extracting the values of senior military leadership from existing doctrine...

  9. IRS Guidelines: Joint IAEA/NEA International Reporting System for Operating Experience

    International Nuclear Information System (INIS)

    2010-01-01

    The International Reporting System for Operating Experience (IRS) is an international system jointly operated by the International Atomic Energy Agency (IAEA) and the OECD Nuclear Energy Agency (OECD/NEA). The fundamental objective of the IRS is to contribute to improving the safety of commercial nuclear power plants which are operated worldwide. This objective can be achieved by providing timely and detailed information on lessons learned from operating and construction experience at the international level. This information could be related to issues and events that are related to safety. The purpose of these guidelines is to describe the system and to give users the necessary background and guidance to enable them to produce IRS reports meeting a high standard of quality while retaining the effectiveness of the system expected by all Member States operating nuclear power plants. As this system is owned by the Member States, the IRS Guidelines have been developed and approved by the IRS National Co-ordinators with the assistance of both Secretariats (IAEA/NEA).

  10. 10 CFR 960.3 - Implementation guidelines.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Implementation guidelines. 960.3 Section 960.3 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Implementation Guidelines § 960.3 Implementation guidelines. The guidelines of this subpart...

  11. 10 CFR 960.5 - Preclosure guidelines.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Preclosure guidelines. 960.5 Section 960.5 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Preclosure Guidelines § 960.5 Preclosure guidelines. The guidelines in this subpart specify the...

  12. 10 CFR 960.4 - Postclosure guidelines.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Postclosure guidelines. 960.4 Section 960.4 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Postclosure Guidelines § 960.4 Postclosure guidelines. The guidelines in this subpart specify the...

  13. Guideline for regulatory agencies in evaluating contents of root cause analysis by operators

    International Nuclear Information System (INIS)

    Hata, Takaya; Makino, Maomi; Kosaka, Atsuhiko

    2008-01-01

    'Guideline for Regulatory Agencies in Evaluating Contents of Root cause Analysis by Operators' was enacted as the policy for new inspection system in Japan. The objective is to indicate the view point to verify the appropriateness of the corrective actions and preventive actions implemented by operators based on root cause analysis and its analysis results. This guideline is leading to take four points into special consideration for adequate application. They are encouragement of further activities of the operators, flexible interpretation of the intention, versatility of the analysis methods and concepts and consideration of no blame culture. Moreover, as view point for regulatory agencies, it indicates with special emphasis that neutrality of the analyzing party, objectivity of analysis result, and logicality of the analysis method are ensured. This guideline shall be continuously reviewed through integration of lessons learned from active use in future. (author)

  14. PROSPER guidelines: Guidelines for peer review and for plant self-assessment of operational experience feedback process

    International Nuclear Information System (INIS)

    2003-01-01

    Effective use of operational performance information is an important element in any plant operator's arrangements for enhancing the operational safety of a nuclear power plant (NPP). This has been recognized in the IAEA Safety Fundamental, The Safety of Nuclear Installations (Safety Series No. 110). Under the technical aspects of safety, one of the principles of operation and maintenance is that the operating organization and the regulatory body shall establish complementary programmes to analyse operating experience to ensure that lessons are learned and acted upon. Such experience shall be shared with relevant national and international bodies. The Convention on Nuclear Safety, which entered into force in July 1996, also recognized the importance of operational experience feedback as a tool of high importance for the safety of nuclear plant operation and its further enhancement. It follows that the arrangements and results achieved under the operation experience feedback process in Member States will be covered by the national report under the Convention and will be subject to periodical review. These principles are further expanded in the IAEA Safety Standards Safety of Nuclear Power Plants: Operation (Safety Standard Series No. NS-R-2, year 2000) under the Feedback of The IAEA-led Peer Review of the effectiveness of the Operational Safety Performance Experience Review process (PROSPER) and associated guidelines have been developed to provide advice and assistance to utilities or individual power plants to strengthen and enhance the effectiveness of operational experience programmes in achieving these fundamental objectives. The objectives of the former IAEA Assessment of Significant Safety Events Team (ASSET) service have been expanded to include an evaluation of the effective use of all operating performance information available to the plant (e.g. external operating experience, internal low-level and near miss event reports and other relevant operating

  15. 10 CFR 960.4-2 - Technical guidelines.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Technical guidelines. 960.4-2 Section 960.4-2 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Postclosure Guidelines § 960.4-2 Technical guidelines. The technical guidelines in this subpart...

  16. 10 CFR 960.5-2 - Technical guidelines.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Technical guidelines. 960.5-2 Section 960.5-2 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Preclosure Guidelines § 960.5-2 Technical guidelines. The technical guidelines in this subpart set...

  17. Advanced control room design review guidelines: Integration of the NUREG-0700 guidelines and development of new human-system interface guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Carter, R.J.

    1997-07-01

    This report documents the work conducted in four tasks of the Nuclear Regulatory Commission (NRC) project entitled Review Criteria for Human Factors Aspects of Advanced Controls and Instrumentation. The purpose of the first task was to integrate the applicable sections of NUREG-0700 into the advanced control room design review (ACRDR) guidelines to ensure that all applicable guidelines are together in one document and conveniently accessible to users. The primary objective of the second task was to formulate a strategy for the development of new ACRDR guidelines that have not otherwise been identified. The main focus of the third task was to modify the individual ACRDR guidelines generated to date to ensure that they are suitable for the intended nuclear power plant (NPP) control station system application. The goal of the fourth task was to develop human factors guidelines for two human-system interface categories that are missing from the current ACRDR guidelines document. During the first task those areas in NUREG-0700 that are not addressed by the ACRDR guidelines document were identified, the areas were subsequently reviewed against six recent industry human factors engineering review guidelines, and the NUREG-0700 guidelines were updated as necessary. In the second task 13 general categories of human-system interface guidelines that are either missing from or not adequately addressed by the ACRDR document were discovered. An approach was derived for the development of new ACRDR guidelines, a preliminary assessment of the available sources that may be useful in the creation of new guidelines and their applicability to the identified human-system interface categories was performed, and an estimate was made of the amount of time and level of effort required to complete the development of needed new ACRDR guidelines. During the third task those NPP control station systems to which the NUREG-0700 and ACRDR guidelines apply were identified, matrices of such

  18. Advanced control room design review guidelines: Integration of the NUREG-0700 guidelines and development of new human-system interface guidelines

    International Nuclear Information System (INIS)

    Carter, R.J.

    1997-07-01

    This report documents the work conducted in four tasks of the Nuclear Regulatory Commission (NRC) project entitled Review Criteria for Human Factors Aspects of Advanced Controls and Instrumentation. The purpose of the first task was to integrate the applicable sections of NUREG-0700 into the advanced control room design review (ACRDR) guidelines to ensure that all applicable guidelines are together in one document and conveniently accessible to users. The primary objective of the second task was to formulate a strategy for the development of new ACRDR guidelines that have not otherwise been identified. The main focus of the third task was to modify the individual ACRDR guidelines generated to date to ensure that they are suitable for the intended nuclear power plant (NPP) control station system application. The goal of the fourth task was to develop human factors guidelines for two human-system interface categories that are missing from the current ACRDR guidelines document. During the first task those areas in NUREG-0700 that are not addressed by the ACRDR guidelines document were identified, the areas were subsequently reviewed against six recent industry human factors engineering review guidelines, and the NUREG-0700 guidelines were updated as necessary. In the second task 13 general categories of human-system interface guidelines that are either missing from or not adequately addressed by the ACRDR document were discovered. An approach was derived for the development of new ACRDR guidelines, a preliminary assessment of the available sources that may be useful in the creation of new guidelines and their applicability to the identified human-system interface categories was performed, and an estimate was made of the amount of time and level of effort required to complete the development of needed new ACRDR guidelines. During the third task those NPP control station systems to which the NUREG-0700 and ACRDR guidelines apply were identified, matrices of such

  19. Preliminary remediation goals for use at the U.S. Department of Energy Oak Ridge Operations Office

    International Nuclear Information System (INIS)

    1995-06-01

    This report presents Preliminary Remediation Goals (PRGs) for use in human health risk assessment efforts under the United States Department of Energy, Oak Ridge Operations Office Environmental Restoration (ER) Division. Chemical-specific PRGs are concentration goals for individual chemicals for specific medium and land use combinations. The PRGs are referred to as risk-based because they have been calculated using risk assessment procedures. Risk-based calculations set concentration limits using both carcinogenic or noncarcinogenic toxicity values under specific exposure pathways. The PRG is a concentration that is derived from a specified excess cancer risk level or hazard quotient. This report provides the ER Division with standardized PRGs which are integral to the Remedial Investigation/Feasibility Study process. By managing the assumptions and systems used in PRG derivation, the Environmental Restoration Risk Assessment Program will be able to control the level of quality assurance associated with these risk-based guideline values

  20. Preliminary remediation goals for use at the U.S. Department of Energy Oak Ridge Operations Office

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-06-01

    This report presents Preliminary Remediation Goals (PRGs) for use in human health risk assessment efforts under the United States Department of Energy, Oak Ridge Operations Office Environmental Restoration (ER) Division. Chemical-specific PRGs are concentration goals for individual chemicals for specific medium and land use combinations. The PRGs are referred to as risk-based because they have been calculated using risk assessment procedures. Risk-based calculations set concentration limits using both carcinogenic or noncarcinogenic toxicity values under specific exposure pathways. The PRG is a concentration that is derived from a specified excess cancer risk level or hazard quotient. This report provides the ER Division with standardized PRGs which are integral to the Remedial Investigation/Feasibility Study process. By managing the assumptions and systems used in PRG derivation, the Environmental Restoration Risk Assessment Program will be able to control the level of quality assurance associated with these risk-based guideline values.

  1. 10 CFR 960.5-1 - System guidelines.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false System guidelines. 960.5-1 Section 960.5-1 Energy DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE REPOSITORY Preclosure Guidelines § 960.5-1 System guidelines. (a) Qualifying conditions—(1) Preclosure...

  2. Operational safety review programmes for nuclear power plants. Guidelines for assessment

    International Nuclear Information System (INIS)

    2002-01-01

    The IAEA has been offering the Operational Safety Review Team (OSART) programme to provide advice and assistance to Member States in enhancing the operational safety of nuclear power plants (NPPs). Simultaneously, the IAEA has encouraged self-assessment and review by Member States of their own nuclear power plants to continuously improve nuclear safety. Currently, some utilities have been implementing safety review programmes to independently review their own plants. Corporate or national operational safety review programmes may be compliance or performance based. Successful utilities have found that both techniques are necessary to provide assurance that (i) as a minimum the NPP meets specific corporate and legal requirements and (ii) management at the NPP is encouraged to pursue continuous improvement principles. These programmes can bring nuclear safety benefits to the plants and utilities. The IAEA has conducted two pilot missions to assess the effectiveness of the operational review programme. Based on these missions and on the experience gained during OSART missions, this document has been developed to provide guidance on and broaden national/corporate safety review programmes in Member States, and to assist in maximizing their benefits. These guidelines are intended primarily for the IAEA team to conduct assessment of a national/corporate safety review programme. However, this report may also be used by a country or utility to establish its own national/corporate safety review programme. The guidelines may likewise be used for self-assessment or for establishing a baseline when benchmarking other safety review programmes. This report consists of four parts. Section 2 addresses the planning and preparation of an IAEA assessment mission and Sections 3 and 4 deal with specific guidelines for conducting the assessment mission itself

  3. Treatment Guidelines for Preoperative Radiation Therapy for Retroperitoneal Sarcoma: Preliminary Consensus of an International Expert Panel

    Energy Technology Data Exchange (ETDEWEB)

    Baldini, Elizabeth H., E-mail: ebaldini@partners.org [Department of Radiation Oncology, Dana-Farber Cancer Institute and Brigham and Women' s Hospital, Boston, Massachusetts (United States); Wang, Dian [Department of Radiation Oncology, Rush University Medical Center, Chicago, Illinois (United States); Haas, Rick L.M. [Department of Radiotherapy, The Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Catton, Charles N. [Department of Radiation Oncology, Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Indelicato, Daniel J. [Department of Radiation Oncology, University of Florida Medical Center, Jacksonville, Florida (United States); Kirsch, David G. [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Roberge, David [Department of Radiation Oncology, Centre Hospitalier de l' Université de Montreal, Montreal, Quebec (Canada); Salerno, Kilian [Department of Radiation Oncology, Roswell Park Cancer Institute, Buffalo, New York (United States); Deville, Curtiland [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Sidney Kimmel Cancer Center, Washington, DC (United States); Guadagnolo, B. Ashleigh [Department of Radiation Oncology, MD Anderson Cancer Center, Houston, Texas (United States); O' Sullivan, Brian [Department of Radiation Oncology, Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Petersen, Ivy A. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States); Le Pechoux, Cecile [Department of Radiotherapy, Institut Gustave-Roussy, Villejuif (France); Abrams, Ross A. [Department of Radiation Oncology, Rush University Medical Center, Chicago, Illinois (United States); DeLaney, Thomas F. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States)

    2015-07-01

    Purpose: Evidence for external beam radiation therapy (RT) as part of treatment for retroperitoneal sarcoma (RPS) is limited. Preoperative RT is the subject of a current randomized trial, but the results will not be available for many years. In the meantime, many practitioners use preoperative RT for RPS, and although this approach is used in practice, there are no radiation treatment guidelines. An international expert panel was convened to develop consensus treatment guidelines for preoperative RT for RPS. Methods and Materials: An expert panel of 15 academic radiation oncologists who specialize in the treatment of sarcoma was assembled. A systematic review of reports related to RT for RPS, RT for extremity sarcoma, and RT-related toxicities for organs at risk was performed. Due to the paucity of high-quality published data on the subject of RT for RPS, consensus recommendations were based largely on expert opinion derived from clinical experience and extrapolation of relevant published reports. It is intended that these clinical practice guidelines be updated as pertinent data become available. Results: Treatment guidelines for preoperative RT for RPS are presented. Conclusions: An international panel of radiation oncologists who specialize in sarcoma reached consensus guidelines for preoperative RT for RPS. Many of the recommendations are based on expert opinion because of the absence of higher level evidence and, thus, are best regarded as preliminary. We emphasize that the role of preoperative RT for RPS has not been proven, and we await data from the European Organization for Research and Treatment of Cancer (EORTC) study of preoperative radiotherapy plus surgery versus surgery alone for patients with RPS. Further data are also anticipated pertaining to normal tissue dose constraints, particularly for bowel tolerance. Nonetheless, as we await these data, the guidelines herein can be used to establish treatment uniformity to aid future assessments of efficacy

  4. Residual energy applications program test and operations report

    International Nuclear Information System (INIS)

    Zander, F.H.

    1980-10-01

    Objective of REAP in the recovery of waste heat at US gaseous diffusion plants by 1984. This report contains policy, objective, and guideline suggestions for utilizing the proposed Energy applied Systems Test (EAST) Facility and for managing EAST operations; preliminary design information on facility support equipment and physical plant; and estimates of initial construction costs and staffing requirements for a two-bay, three-shift operation

  5. Utilizing the ECHO Model in the Veterans Health Affairs System: Guidelines for Setup, Operations and Preliminary Findings

    Directory of Open Access Journals (Sweden)

    Herschel Knapp

    2015-06-01

    Full Text Available Background: In 2011, the Veterans Health Administration (VHA consulted with the Project ECHO (Extension for Community Healthcare Outcomes team at the University of New Mexico, Albuquerque, to reproduce their successful model within the VHA. Methods: The VHA launched SCAN-ECHO (Specialty Care Access Network-Extension for Community Healthcare Outcomes, a multisite videoconferencing system to conduct live clinical consultations between specialists at a VHA Medical Center (hospital and primary care providers stationed at satellite VHA CBOCs (Community-Based Outpatient Clinic. Results: Analysis of the first three years rendered a mean attendee satisfaction of 89.53% and a consultation satisfaction score of 88.10%. About half of the SCAN-ECHO consultations resulted in patients receiving their treatment from their local primary care providers; the remaining half were referred to the VHA Medical Center when the treatment involved equipment or services not available at the CBOCs (e.g., MRI, surgery. Conclusion: This paper details the setup, operation logistics and preliminary findings, suggesting that SCAN-ECHO is a viable model for providing quality specialty clinical consultation service, prompter access to care, reduced commutes and continuing education. Additionally, the use of a secured Internet-based videoconferencing system that supports connectivity to multiple (mobile devices could expand the utilization of this service.

  6. SALTO guidelines. Guidelines for peer review of long term operation and ageing management of nuclear power plants

    International Nuclear Information System (INIS)

    2008-01-01

    other and apply good practices in dealing with LTO of NPPs. The peer review service is also an important mechanism through which the IAEA supports Member States in enhancing the safety of NPPs. The IAEA has conducted various types of safety review services that indirectly address some aspects of LTO, including safety review services for design, engineering, operation and external hazards. OSART (Operational Safety Review Team) services include some review of ageing management programmes. In addition, several Member States have requested AMAT (Ageing Management Assessment Team) missions. Through these activities and considering the increasing average age of NPPs connected to the grid worldwide, it was recognized that a comprehensive engineering safety review service on LTO would be very useful to Member States. The Safe Long Term Operation (SALTO) peer review is a new comprehensive engineering safety review service directly addressing strategy and the key elements for safe LTO of NPPs, which includes AMAT objectives and complements OSART reviews. The SALTO peer review service is designed to assist NPP operators in adopting a proper approach to long term operation of their plants and in implementing complete and appropriate activities to ensure that plant safety will be maintained during the LTO period. The SALTO peer review service can be tailored to focus on AMPs and/or on other programmes related to LTO to support the Member State in enhancing the safety of its NPPs. The SALTO peer review service can also support regulators in establishing or improving regulatory and licensing strategies for LTO of NPPs. These guidelines are primarily intended for members of the SALTO review team and they provide a basic structure and common reference for peer reviews of LTO. However, the guidelines could provide useful information to operating organizations of NPPs (or technical support organizations) for carrying out their own self-assessments or comprehensive programme reviews. The

  7. Space Elevators Preliminary Architectural View

    Science.gov (United States)

    Pullum, L.; Swan, P. A.

    Space Systems Architecture has been expanded into a process by the US Department of Defense for their large scale systems of systems development programs. This paper uses the steps in the process to establishes a framework for Space Elevator systems to be developed and provides a methodology to manage complexity. This new approach to developing a family of systems is based upon three architectural views: Operational View OV), Systems View (SV), and Technical Standards View (TV). The top level view of the process establishes the stages for the development of the first Space Elevator and is called Architectural View - 1, Overview and Summary. This paper will show the guidelines and steps of the process while focusing upon components of the Space Elevator Preliminary Architecture View. This Preliminary Architecture View is presented as a draft starting point for the Space Elevator Project.

  8. Preliminary guidelines for the evaluation and management of dyslipidemia in adults infected with human immunodeficiency virus and receiving antiretroviral therapy: Recommendations of the Adult AIDS Clinical Trial Group Cardiovascular Disease Focus Group

    NARCIS (Netherlands)

    Dubé, M. P.; Sprecher, D.; Henry, W. K.; Aberg, J. A.; Torriani, F. J.; Hodis, H. N.; Schouten, J. [=Judith; Levin, J.; Myers, G.; Zackin, R.; Nevin, T.; Currier, J. S.

    2000-01-01

    Dyslipidemia is a prevalent condition that affects patients infected with human immunodeficiency virus (HIV) who are receiving antiretroviral therapy, These preliminary recommendations summarize the current understanding in this area and propose guidelines for management. Existing guidelines for the

  9. Guidelines for the content of records to support nuclear power plant operation, maintenance, and modification (NCIG-08): Volume 1, Guidelines: Final report

    International Nuclear Information System (INIS)

    Reedy, R.F.; Hegglin, D.P.

    1988-11-01

    The record systems at many nuclear power plant sites are becoming overloaded with unnecessary and superfluous records. The reason for this overload is that although the Codes and Standards list the record types to be retained, there is no definition for the contents of the records. This encourages varied interpretations which often lead to the approach of ''save everything''. This document provides guidelines for the content of records to support nuclear power plant operation, maintenance and modification. These Guidelines are based on an engineering approach to identify which data in the records are of ''significant value'' in (1) demonstrating capability for safe operation; (2) maintaining, reworking, repairing, replacing, or modifying an item; (3) determining the cause of an accident or malfunction of an item; and (4) providing required baseline data for in-service inspection. Particular topical issues affecting record retention needs, such as plant life extension activities, may require additional evaluation of data or records. By identifying the data to be retained in the records, it is possible to modify the record management system to substantially reduce the amount of unnecessary information being retained in the records. These Guidelines will provide for more uniform interpretation of requirements. The Guidelines are meant as an interpretation of current Codes, Standards and Regulatory Guides, and not as new requirements. Should any conflict exist between these Guidelines and the specified requirements of the NRC Regulations, the regulations govern. 4 tabs

  10. Operating Plan and Guidelines (2011 - 2016)

    International Nuclear Information System (INIS)

    2011-01-01

    The Committee on Nuclear Regulatory Activities (CNRA) of the OECD Nuclear Energy Agency (NEA) is an international committee made up primarily of senior nuclear regulators. It was established in 1989 as a forum for the exchange of information and experience among regulatory organisations and for the review of developments which could affect regulatory requirements. The Committee is responsible for the programme of the NEA, concerning the regulation, licensing and inspection of nuclear installations. In particular, the Committee reviews current practices and operating experience. The Joint CSNI/CNRA Strategic Plan states that: The Operating Plan for each committee aligns with the Joint CNRA/ CSNI Strategic Plan. The Committee's Operating Plans describes each Committee's organisation, priorities, and operating procedures to be used in fulfilling their mandates in accordance with this strategic plan. Specific attention will be given to ensure that cross-cutting issues are satisfactorily dealt with. This report represents such an operating plan. The intention is that it should fit onto a new third rung on the ladder representing the hierarchy of documents that govern the work of CNRA. At the top of this hierarchy is the Strategic Plan of the NEA; immediately below that is the Joint CSNI/CNRA Strategic Plan; followed by the new operating plan and the guidelines for methods of work. This plan sets the basis for establishing the current CNRA Programme of Work. Since the issuance of the last plan in 2007 there has been a significant shift and many member countries are now constructing new facilities or in the process of legislative or technical processing for new licenses. This comes along in an atmosphere in which current operating plants requesting power up-rates, extended licenses, and substantial activity in new licensing and new construction. It is clear that all these activities require similar attention from the regulators and operators, and the responsibilities

  11. Preliminary remediation goals for use at the US Department of Energy Oak Ridge Operations Office. Revision 1

    International Nuclear Information System (INIS)

    1996-05-01

    This technical memorandum presents Preliminary Remediation Goals (PRGs) for use in human health risk assessment efforts under the United States Department of Energy, Oak Ridge Operations Office Environmental Restoration (ER) Division. This document provides the ER Division with standardized PRGs which are integral to the Remedial Investigation/Feasibility Study process. They are used during project scooping (Data Quality Objectives development), in screening level risk assessments to support early action or No Further Investigation decisions, and in the baselines risk assessment where they are employed in the selection of chemicals of potential concern. The primary objective of this document is to standardize these values and eliminate any duplication of effort by providing PRGs to all contractors involved in risk activities. In addition, by managing the assumptions and systems used in PRG derivation, the ER Risk Assessment Program will be able to control the level of quality assurance associated with these risk-based guideline values

  12. Preliminary remediation goals for use at the US Department of Energy Oak Ridge Operations Office. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-05-01

    This technical memorandum presents Preliminary Remediation Goals (PRGs) for use in human health risk assessment efforts under the United States Department of Energy, Oak Ridge Operations Office Environmental Restoration (ER) Division. This document provides the ER Division with standardized PRGs which are integral to the Remedial Investigation/Feasibility Study process. They are used during project scooping (Data Quality Objectives development), in screening level risk assessments to support early action or No Further Investigation decisions, and in the baselines risk assessment where they are employed in the selection of chemicals of potential concern. The primary objective of this document is to standardize these values and eliminate any duplication of effort by providing PRGs to all contractors involved in risk activities. In addition, by managing the assumptions and systems used in PRG derivation, the ER Risk Assessment Program will be able to control the level of quality assurance associated with these risk-based guideline values.

  13. Preliminary Analysis of Helicopter Options to Support Tunisian Counterterrorism Operations

    Science.gov (United States)

    2016-04-27

    helicopters from Sikorsky to fulfill a number of roles in counterterrorism operations. Rising costs and delays in delivery raised the question of...whether other cost-effective options exist to meet Tunisia’s helicopter requirement. Approach Our team conducted a preliminary assessment of...alternative helicopters for counterterrorism air assault missions. Any decision to acquire an aircraft must consider many factors, including technical

  14. Commissioning and preliminary operation of HL-2A tokamak

    International Nuclear Information System (INIS)

    Liu Dequan; Liu Yong; Yan Jianchen; Cao Zeng; Yang Qingwei; Zhou Caipin; Li Xiaodong

    2005-01-01

    HL-2A is a divertor tokamak located at new site of Southwestern Institute of Physics (SWIP), Chengdu, China. It can be operated in double-null and single-null divertor with closed configurations. The effects of the divertor on impurity behaviors, MHD instabilities, transport, wall conditioning and divertor physics are key issues to be studied during the first step operation on HL-2A. Preliminary experiments with limiter and single null divertor configurations were carried out in 2003. Main parameters achieved are the plasma current 168 KA, duration time of 920 ms and plasma linear-averaged density of 1.7 x 10 19 m -3 . The impurities, especially of low Z, are clearly decreased during the divertor experiments

  15. OSART guidelines

    International Nuclear Information System (INIS)

    1988-02-01

    The IAEA Operational Safety Review Team (OSART) programme provides advice and assistance to Member States to enhance the operational safety of nuclear power plants. These OSART Guidelines provide overall guidance for the experts to ensure the consistency and comprehensiveness of the operational safety review. Specific guidelines are provided as guide for the systematic review in the following areas important to operational safety: management, organization and administration, training and qualification, operations, maintenance, technical support, radiation protection, chemistry, emergency planning and preparedness

  16. Human factors guidelines and methodology in the design of a user computer interface: a case study

    International Nuclear Information System (INIS)

    Richards, R.E.; Gilmore, W.E.; Haney, L.N.

    1986-01-01

    In this case study, human factors personnel were requested to participate in a project team of programmers and operations specialists to design a cathode ray tube (CRT) display system for a complex process control application. This presentation describes the process and benefits obtained by incorporating human factors guidelines and methods in system design. Standard human engineering guidelines and techniques were utilized by the project team. In addition, previously published documents and research findings sponsored by the US Nuclear Regulatory Commission (USNRC) were used. Preliminary tasks involved a review of the draft plant procedures. Then, interviews with operators were conducted to establish the initial information for the displays. These initial requirements were evaluated against existing guidelines and criteria to determine the optimal presentation formats. Detailed steps of the approaches used, design decisions made, and tradeoffs that resulted in the final user acceptable design are discussed. 7 refs., 2 figs

  17. Preliminary definition of the DOE/OCRWM transportation operating system: Final report

    International Nuclear Information System (INIS)

    Rawl, R.R.; Kline, S.C.

    1988-01-01

    This paper is based on the report ''Preliminary Definition of the Transportation Operations System'' and presents a summary of the preliminary definition of transportation operations activities for the cask shipment cycle, commencing with the dispatch of an empty cask, to loading and unloading of cask contents, and preparation of the empty cask for redispatch. It first presents a high-level description of the transportation cycle and then further describes each of the major activities in greater detail. For simplicity of presentation, the highway mode of transport is most often used to describe activities. The reader should keep in mind that the use of other modes will slightly alter the activities and possibly the sequences. Major activities and functions of the system are organized into a first cut of how they could be allocated to specific facilities. The reader should keep in mind that the assignment of functions and the aggregation of these into specific facilities are tasks which have yet to be performed. This paper simply presents a first look at possible groupings of the functions on a facility basis. 12 figs

  18. Guidelines for the presentation of emergency operating procedures using advanced information technology

    International Nuclear Information System (INIS)

    Green, M.; Hollnagel, E.; Niwa, Yuji

    1994-01-01

    New methods of information presentation and interface design are changing the conditions for work in the modern NPP control room. One area receiving considerable attention is that of Emergency Operating Procedures (EOP). Conventionally such procedures are presented using hard copy manuals; however, development in IT means that there are new opportunities for the computerization of such procedures. This paper reports on the development of human factors guidelines for the computerized presentation of EOPs. After identifying the principle stages in the transition from procedures as documents to fully automated procedures, computerised procedure presentation is briefly discussed. Guidelines for the presentation of such procedures are outlined starting with the high level goals for guidelines themselves. Such goals also constitute the criteria against which the computerized procedures are measured during implementation. Six dimensions describing computerized procedure presentation are presented and two are explore in more detail by identifying points along each dimension that characterize different levels of IT sophistication. (author). 8 refs, 1 tab

  19. Criteria for safety related nuclear plant operator actions: a preliminary assessment of available data

    International Nuclear Information System (INIS)

    Haas, P.M.; Bott, T.F.

    1982-01-01

    The need for a quantitative data base on the reliability of nuclear power plant operators has long been recognised by human factors and reliability analysts, and the great need for further assessment of operator performance under accident conditions has been dramatically emphasised by the incident at Three Mile Island-2. In the US, an effort has been under way for a number of years to develop a design standard to define when required manual operator action can be accepted as part of a nuclear plant design basis. To provide the necessary data base to support such standards and the necessary quantitative assessment of operator reliability, the US Nuclear Regulatory Commission is sponsoring a study at Oak Ridge National Laboratory to develop the data base. A preliminary assessment, completed in April 1979, concluded that sufficient data from US operating experience did not exist to provide an adequate data base. A programme of research using full-scope nuclear plant simulators and results that are correlated to field data was suggested. That programme was recently initiated. This paper reviews the approach, results and conclusions of the preliminary assessment and summarises the planned research programme of simulator studies. (author)

  20. Guidelines for operator competence - Optimising facility management processes; Leitfaden Betreiberkompetenz. Schritt fuer Schritt Facility Management Prozesse optimieren

    Energy Technology Data Exchange (ETDEWEB)

    Moser, R

    2005-06-15

    This brochure issued by IFMA (International Facility Management Association) Switzerland and the Swiss Federal Office of Energy (SFOE) presents interactive guidelines for energy management in the area of facility management. These guidelines are based on the results of a project carried out by the International Energy Agency's Annex 40 'Operator competence'. The guidelines provide a step-by-step guide from initial analysis through to successful project completion and answer many questions that may crop up during the process. The focus is placed on energy aspects. Tools and 14 sample process descriptions are provided along with practical examples. Theoretical aspects are also presented and discussed, including models for operator roles and the processes involved. Also, change, risk and knowledge management are examined. Notes and information on possibilities for further education are presented.

  1. Guidelines for operator competence - Optimising facility management processes; Leitfaden Betreiberkompetenz. Schritt fuer Schritt Facility Management Prozesse optimieren

    Energy Technology Data Exchange (ETDEWEB)

    Moser, R.

    2005-06-15

    This brochure issued by IFMA (International Facility Management Association) Switzerland and the Swiss Federal Office of Energy (SFOE) presents interactive guidelines for energy management in the area of facility management. These guidelines are based on the results of a project carried out by the International Energy Agency's Annex 40 'Operator competence'. The guidelines provide a step-by-step guide from initial analysis through to successful project completion and answer many questions that may crop up during the process. The focus is placed on energy aspects. Tools and 14 sample process descriptions are provided along with practical examples. Theoretical aspects are also presented and discussed, including models for operator roles and the processes involved. Also, change, risk and knowledge management are examined. Notes and information on possibilities for further education are presented.

  2. Photovoltaic system criteria documents. Volume 1: Guidelines for evaluating the management and operations planning of photovoltaic applications

    Science.gov (United States)

    Koenig, John C.; Billitti, Joseph W.; Tallon, John M.

    1979-01-01

    Guidelines are provided to the Field Centers for organization, scheduling, project and cost control, and performance in the areas of project management and operations planning for Photovoltaics Test and Applications. These guidelines may be used in organizing a T and A Project Team for system design/test, site construction and operation, and as the basis for evaluating T and A proposals. The attributes are described for project management and operations planning to be used by the Field Centers. Specifically, all project management and operational issues affecting costs, schedules and performance of photovoltaic systems are addressed. Photovoltaic tests and applications include residential, intermediate load center, central station, and stand-alone systems. The sub-categories of system maturity considered are: Initial System Evaluation Experiments (ISEE); System Readiness Experiments (SRE); and Commercial Readiness Demonstration Projects (CRDP).

  3. Evaluation of a Pain Management Education Program and Operational Guideline on Nursing Practice, Attitudes, and Pain Management.

    Science.gov (United States)

    Bonkowski, Sara L; De Gagne, Jennie C; Cade, Makia B; Bulla, Sally A

    2018-04-01

    Nurses lack adequate pain management knowledge, which can result in poorly managed postsurgical pain. This study aimed to develop, implement, and evaluate pain management education and operational guidelines to improve nursing knowledge and pain management. This quality improvement project employed convenience samples of surgical oncology nurses and postoperative patients. The intervention involved an online module, live education, and operational guideline for pain management. Nurses completed pre- and postintervention practice and attitudes surveys. Random chart reviews of intravenous narcotic administrations the day before discharge were completed to evaluate whether narcotic administration changed after intervention. Readmissions and Hospital Consumer Assessment of Healthcare Providers and Systems data were collected to determine whether the intervention influenced patient satisfaction. A statistically significant improvement in nursing practice and intravenous narcotic administrations demonstrated changes to pain management practices employed by the nursing staff. Although not statistically significant, fewer pain-related readmissions occurred postintervention. Findings demonstrate that targeted pain management continuing education, paired with operational guidelines, improves nursing practice and decreases intravenous narcotic administrations prior to discharge. J Contin Educ Nurs. 2018;49(4):178-185. Copyright 2018, SLACK Incorporated.

  4. IAEA/NEA incident reporting system (IRS). Reporting guidelines. Feedback from safety related operating experience for nuclear power plants

    International Nuclear Information System (INIS)

    1998-01-01

    The Incident Reporting System (IRS) is an international system jointly operated by the International Atomic Energy Agency (IAEA) and the Nuclear Energy Agency of the Organisation for Economic Cooperation and Development (OECD/NEA). The fundamental objective of the IRS is to contribute to improving the safety of commercial nuclear power plants (NPPs) which are operated worldwide. This objective can be achieved by providing timely and detailed information on both technical and human factors related to events of safety significance which occur at these plants. The purpose of these guidelines, which supersede the previous IAEA Safety Series No. 93 (Part II) and the NEA IRS guidelines, is to describe the system and to give users the necessary background and guidance to enable them to produce IRS reports meeting a high standard of quality while retaining the high efficiency of the system expected by all Member States operating nuclear power plants. These guidelines have been jointly developed and approved by the NEA/IAEA

  5. Hygiene guideline for the planning, installation, and operation of ventilation and air-conditioning systems in health-care settings - Guideline of the German Society for Hospital Hygiene (DGKH).

    Science.gov (United States)

    Külpmann, Rüdiger; Christiansen, Bärbel; Kramer, Axel; Lüderitz, Peter; Pitten, Frank-Albert; Wille, Frank; Zastrow, Klaus-Dieter; Lemm, Friederike; Sommer, Regina; Halabi, Milo

    2016-01-01

    Since the publication of the first "Hospital Hygiene Guideline for the implementation and operation of air conditioning systems (HVAC systems) in hospitals" (http://www.krankenhaushygiene.de/informationen/fachinformationen/leitlinien/12) in 2002, it was necessary due to the increase in knowledge, new regulations, improved air-conditioning systems and advanced test methods to revise the guideline. Based on the description of the basic features of ventilation concepts, its hygienic test and the usage-based requirements for ventilation, the DGKH section "Ventilation and air conditioning technology" attempts to provide answers for the major air quality issues in the planning, design and the hygienically safe operation of HVAC systems in rooms of health care.

  6. The quality of operative note taking: an audit using the Royal College of Surgeons Guidelines as the gold standard.

    Science.gov (United States)

    Shayah, A; Agada, F O; Gunasekaran, S; Jassar, P; England, R J A

    2007-04-01

    To assess the quality of operative note keeping and compare the results with the Royal College of Surgeons (RCS) of England guidelines 'Good Surgical Practice' as the gold standard. ENT Department at Hull Royal Infirmary, University Hospital. A hundred consecutive operative notes were selected between November 2005 and January 2006. The documentation of the operative notes in each case was compared with the RCS of England guidelines. All surgeons were made aware of the results of the first cycle and the guidelines were made available in all ENT theatres in the form of a printed aide-memoir. A second audit cycle was then carried out prospectively between April and June 2006. The results demonstrated a change in practice in key areas. The 1st cycle results showed the documentation of patient identification (94%), name of surgeon (98%) and clearly written postoperative instructions (94%). However, surgeons performed suboptimally at recording the name of assistant (82%), operative diagnosis (46%), the incision type (87%) and the type of wound closure (83%). After introducing the aide-memoir, the second cycle demonstrated a change in practice with 100% documentation in most of the assessed parameters except that the time of surgery and the type of surgery (emergency or elective) were not adequately recorded. We recommend that all surgical departments should have the RCS guidelines as an aide-memoir in theatres to enhance the quality and standardise operative note recording.

  7. Idiopathic granulomatous lobular mastitis - report of 43 cases from iran; introducing a preliminary clinical practice guideline.

    Science.gov (United States)

    Omranipour, Ramesh; Mohammadi, S-Farzad; Samimi, Parisa

    2013-12-01

    We aimed to report a large series of idiopathic granulomatous lobular mastitis (IGLM) from Iran and sketch preliminary clinical practice guidelines (CPG) for approaching an inflammatory breast mass. In a retrospective records review, 43 consecutive IGLM cases were studied. Data on baseline, clinical, imaging, and pathologic characteristics were collected. The mean age of the women was 33.5 years. All but 1 were married and had given birth. 16% had a cancer-like presentation. Inflammatory signs, architectural distortion, and a nodular pattern were the most common findings clinically, mammographically and ultrasonographically, respectively. 29.5% of the pathological reports indicated necrosis which was more common in younger subjects (p = 0.016); microabscesses were associated with a shorter lactation course (p = 0.006). Corticosteroids had been used as the initial treatment modality in 51%, immunosuppressive agents had not been administered, and a 16% relapse rate was recorded. We recognized the need for a multidisciplinary approach covering radiology, oncology, and surgery to best handle diagnostic and therapeutic issues and manage relevant infections as well as the major differential diagnosis, i.e. malignancy. We hypothesized that a shorter lactation period may cause more milk stasis and extravasation and be contributory to IGLM. CPGs are needed to incorporate the needed multidisciplinary approach and to standardize IGLM care. We present one such guideline.

  8. Hygiene guideline for the planning, installation, and operation of ventilation and air-conditioning systems in health-care settings – Guideline of the German Society for Hospital Hygiene (DGKH

    Directory of Open Access Journals (Sweden)

    Külpmann, Rüdiger

    2016-02-01

    Full Text Available Since the publication of the first “Hospital Hygiene Guideline for the implementation and operation of air conditioning systems (HVAC systems in hospitals” ( in 2002, it was necessary due to the increase in knowledge, new regulations, improved air-conditioning systems and advanced test methods to revise the guideline. Based on the description of the basic features of ventilation concepts, its hygienic test and the usage-based requirements for ventilation, the DGKH section “Ventilation and air conditioning technology” attempts to provide answers for the major air quality issues in the planning, design and the hygienically safe operation of HVAC systems in rooms of health care.

  9. RSK-guidelines for PWR reactors

    International Nuclear Information System (INIS)

    1979-01-01

    The RSK guidelines for PWA reactors of April 24, 1974, have been revised and amended in this edition. The RSK presents a summary of safety requirements to be observed in the design, construction, and operation of PWR reactors in the form of guidelines. From January 1979 onwards these guidelines will be the basis of siting and safety considerations for new PWR reactors, and newly built nuclear power plants will have to form these guidelines. They are not binding for existing nuclear power plants under construction or in operation. It will be a matter of individual discussion whether or not the guidelines will be applied in these plants. The main purpose of the guidelines is to facilitate discussion among RSK members and to give early information on necessary safety requirements. If the guidelines are observed by producers and operators, the RSK will make statements on individual projects at short notice. (orig./HP) [de

  10. EuroFIR Guideline on calculation of nutrient content of foods for food business operators.

    Science.gov (United States)

    Machackova, Marie; Giertlova, Anna; Porubska, Janka; Roe, Mark; Ramos, Carlos; Finglas, Paul

    2018-01-01

    This paper presents a Guideline for calculating nutrient content of foods by calculation methods for food business operators and presents data on compliance between calculated values and analytically determined values. In the EU, calculation methods are legally valid to determine the nutrient values of foods for nutrition labelling (Regulation (EU) No 1169/2011). However, neither a specific calculation method nor rules for use of retention factors are defined. EuroFIR AISBL (European Food Information Resource) has introduced a Recipe Calculation Guideline based on the EuroFIR harmonized procedure for recipe calculation. The aim is to provide food businesses with a step-by-step tool for calculating nutrient content of foods for the purpose of nutrition declaration. The development of this Guideline and use in the Czech Republic is described and future application to other Member States is discussed. Limitations of calculation methods and the importance of high quality food composition data are discussed. Copyright © 2017. Published by Elsevier Ltd.

  11. Guidelines for prediction of irradiation embrittlement of operating WWER-440 reactor pressure vessels

    International Nuclear Information System (INIS)

    2005-06-01

    This TECDOC has been developed under an International Atomic Energy Agency Coordinated Research Project (CRP) entitled Evaluation of Radiation Damage of WWER Reactor Pressure Vessels (RPV) using Database on RPV Materials to develop the guidelines for prediction of radiation damage to WWER-440 PRVs. The WWER-440 RPV was designed by OKB Gidropress, Russian Federation, the general designer. Prediction of irradiation embrittlement of RPV materials is usually done in accordance with relevant codes and standards that are based on the large amounts of information from surveillance and research programmes. The existing Russian code (standard for strength calculations of components and piping in NPPs - PNAE G 7-002-86) for the WWER RPV irradiation embrittlement assessment was approved more than twenty years ago and based mostly on the experimental data obtained in research reactors with accelerated irradiation. Nevertheless, it is still in use and generally consistent with new data. The present publication presents the analyses using all available data required for more precise prediction of radiation embrittlement of WWER-440 RPV materials. Based on the fact that it contains a large amount of data from surveillance programmes as well as research programmes, the IAEA International Database on RPV Materials (IDRPVM) is used for the detailed analysis of irradiation embrittlement of WWER RPV materials. Using IDRPVM, the guideline is developed for assessment of irradiation embrittlement of RPV ferritic materials as a result of degradation during operation. Two approaches, i.e. transition temperatures based on Charpy impact notch toughness, as well as based on static fracture toughness tests, are used in RPV integrity evaluation. The objectives of the TECDOC are the analysis of irradiation embrittlement data for WWER- 440 RPV materials using IDRPVM database, evaluation of predictive formulae depending on chemical composition of the material, neutron fluence, flux, and

  12. Idiopathic Granulomatous Lobular Mastitis – Report of 43 Cases from Iran; Introducing a Preliminary Clinical Practice Guideline

    Science.gov (United States)

    Omranipour, Ramesh; Mohammadi, S-Farzad; Samimi, Parisa

    2013-01-01

    Summary Background We aimed to report a large series of idiopathic granulomatous lobular mastitis (IGLM) from Iran and sketch preliminary clinical practice guidelines (CPG) for approaching an inflammatory breast mass. Patients and Methods In a retrospective records review, 43 consecutive IGLM cases were studied. Data on baseline, clinical, imaging, and pathologic characteristics were collected. Results The mean age of the women was 33.5 years. All but 1 were married and had given birth. 16% had a cancer-like presentation. Inflammatory signs, architectural distortion, and a nodular pattern were the most common findings clinically, mammographically and ultrasonographically, respectively. 29.5% of the pathological reports indicated necrosis which was more common in younger subjects (p = 0.016); microabscesses were associated with a shorter lactation course (p = 0.006). Corticosteroids had been used as the initial treatment modality in 51%, immunosuppressive agents had not been administered, and a 16% relapse rate was recorded. We recognized the need for a multidisciplinary approach covering radiology, oncology, and surgery to best handle diagnostic and therapeutic issues and manage relevant infections as well as the major differential diagnosis, i.e. malignancy. Conclusion We hypothesized that a shorter lactation period may cause more milk stasis and extravasation and be contributory to IGLM. CPGs are needed to incorporate the needed multidisciplinary approach and to standardize IGLM care. We present one such guideline. PMID:24550752

  13. OSART guidelines. 1992 edition

    International Nuclear Information System (INIS)

    1992-01-01

    The IAEA Operational Safety Review Team (OSART) Guidelines provide overall guidance for the experts to ensure the consistency and comprehensiveness of the operational safety review. Specific guidelines are provided as a guide for the systematic review in the following areas important to operational safety: management, organization and administration, training and qualification, operations, maintenance, technical support, radiation protection, chemistry, emergency planning and preparedness. Additional guidance and reference material has been prepared by the IAEA to complement the expertise of the OSART members

  14. Guidelines for the regulatory review of the human reliability analysis in PSAs

    International Nuclear Information System (INIS)

    Reer, Bernhard; Dang, V.N.; Hirschberg, Stefan; Meyer, Patrick

    2000-01-01

    In the review guidelines recently developed for the Swiss Federal Nuclear Inspectorate, the Human Reliability Analysis (HRA) is reviewed in two stages. The preliminary review is aimed at identifying major shortcomings and potential issues to be examined in the detailed review. The detailed review comprehensively addresses the overall adequacy and transparency of the HRA. For the two review stages, 97 indicators are defined in terms of questions focusing on verifiable features of the methodology, implementation and results. The guidelines provide steps for information gathering and present examples of acceptable practices as well as of potential deficiencies. Both review stages may result in requests for clarification, additional documentation or analyses. The first applications of the guidelines consist of the preliminary reviews of two HRAs. (author)

  15. Safety Standard for Oxygen and Oxygen Systems: Guidelines for Oxygen System Design, Materials Selection, Operations, Storage, and Transportation

    Science.gov (United States)

    1996-01-01

    NASA's standard for oxygen system design, materials selection, operation, and transportation is presented. Minimum guidelines applicable to NASA Headquarters and all NASA Field Installations are contained.

  16. Preliminary evaluation of rotational Vol-oxidizer for hot cell operation - 5320

    International Nuclear Information System (INIS)

    Kim, Y.H.; Lee, J.W.; Cho, Y.Z.; Ahn, D.H.; Song, K.C.

    2015-01-01

    KAERI is developing a mechanical head-end process for pyro-processing. As a piece of the processing equipment, a vol-oxidizer that can handle several tens of kg of HM/batch is under development to supply U 3 O 8 powders to an electrolytic reduction (ER) reactor. To operate a vol-oxidizer in a hot cell, the reactor should be optimized by the mechanical design, and the vol-oxidizer should have a high hull recovery rate. In addition, a vol-oxidizer for hot cell demonstrations that handles the spent fuel of high radiation virulence in a limited space should have a small size and not scatter in its outlet. In this paper, we aim at a preliminary evaluation of a rotational vol-oxidizer for hot cell operation. To evaluate the preliminary situation, we produced a theoretical equation of an optimum reactor size, and verification tests were conducted using an acryl vessel and zircaloy-4 tube according to various weights and lengths. In addition, we predicted the terminal velocity of U 3 O 8 using the terminal velocity of SiO 2 , which will determine the optimum air flux, and through an oxidation experiment, we verified the theory form to detect the existence of U 3 O 8 powder in a discharge filter. In addition, hull separation tests were conducted using a reactor and hulls with a 50 kg HM/batch for the recovery rate of the hulls. The results indicate that we obtained an appropriate air flux so as to not cause U 3 O 8 powder dispersion from using a Stokes equation and density ratio equation prior to the demonstration. The optimum flow and experimental results of the hull separation test have been applied for the design of the demonstration oxidizer, and the operation conditions of the oxidizer were produced. (authors)

  17. Digital Skill Training Research: Preliminary Guidelines for Distributed Learning

    National Research Council Canada - National Science Library

    Childs, Jerry

    2001-01-01

    This task was aimed at the development of guidelines for distributed learning (DL). A matrix was generated to evaluate the effectiveness of various DL media for training representative knowledge/skill types...

  18. Los Alamos National Laboratory corregated metal pipe saw facility preliminary safety analysis report. Volume I

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1990-09-19

    This Preliminary Safety Analysis Report addresses site assessment, facility design and construction, and design operation of the processing systems in the Corrugated Metal Pipe Saw Facility with respect to normal and abnormal conditions. Potential hazards are identified, credible accidents relative to the operation of the facility and the process systems are analyzed, and the consequences of postulated accidents are presented. The risk associated with normal operations, abnormal operations, and natural phenomena are analyzed. The accident analysis presented shows that the impact of the facility will be acceptable for all foreseeable normal and abnormal conditions of operation. Specifically, under normal conditions the facility will have impacts within the limits posted by applicable DOE guidelines, and in accident conditions the facility will similarly meet or exceed the requirements of all applicable standards. 16 figs., 6 tabs.

  19. Preliminary Concept of Operations for a Global Cylinder Identification and Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Whitaker, J. M. [ORNL; White-Horton, J. L. [ORNL; Morgan, J. B. [InSolves Associates

    2013-08-01

    This report describes a preliminary concept of operations for a Global Cylinder Identification and Monitoring System that could improve the efficiency of the International Atomic Energy Agency (IAEA) in conducting its current inspection activities and could provide a capability to substantially increase its ability to detect credible diversion scenarios and undeclared production pathways involving UF6 cylinders. There exist concerns that a proliferant State with access to enrichment technology could obtain a cylinder containing natural or low-enriched uranium hexafluoride (UF6) and produce a significant quantity (SQ)1 of highly enriched uranium in as little as 30 days. The National Nuclear Security Administration (NNSA) through the Next Generation Safeguards Initiative sponsored a multi-laboratory team to develop an integrated system that provides for detecting scenarios involving 1) diverting an entire declared cylinder for enrichment at a clandestine facility, 2) misusing a declared cylinder at a safeguarded facility, and 3) using an undeclared cylinder at a safeguarded facility. An important objective in developing this integrated system was to improve the timeliness for detecting the cylinder diversion and undeclared production scenarios. Developing this preliminary concept required in-depth analyses of current operational and safeguards practices at conversion, enrichment, and fuel fabrication facilities. The analyses evaluated the processing, movement, and storage of cylinders at the facilities; the movement of cylinders between facilities (including cylinder fabrication); and the misuse of safeguarded facilities.

  20. Operational research on implementation of tuberculosis guidelines in Mozambique

    NARCIS (Netherlands)

    Brouwer, M.A.

    2015-01-01

    The overall objective of this thesis is to assess how guideline implementation and evaluation contribute to health care decision-making and to assess what critical factors contribute to successful or unsuccessful implementation of TB control guidelines through case studies mainly conducted in

  1. Guidelines for the abandonment operations in the petroleum and gas industry

    International Nuclear Information System (INIS)

    Bedoya V, Julio Cesar; Zapata S, Carmen Elena

    2003-01-01

    Decommission operations, in the hydrocarbons sector, are essential to maintain a clean environment. We propose a guidelines to provide a methodology to standardize the decommission procedures establishing a logical structure in the operations. It shows the generations of possible decommission alternatives. They are picked up in three types, abandonment that is to leave the infrastructure in the place, dismantlement that is the total dismounts of the pieces that compose it, reutilization that will be the new use that will be given to the things. Finally, through an appropriate environmental management, to select the best decommission alternatives that mitigate the impacts and the generation of environmental passives. A project can be presented the abandonment, the reutilization and the dismantlement simultaneously. Also, there are forms to organize and to evaluate the process of decommission. The interdisciplinary work has great importance in this process, as well as an appropriate social management with the affected communities

  2. Guidelines and workbook for assessment of organization and administration of utilities seeking operating license for a nuclear power plant. Guidelines for utility organization and administration plan. Volume 1

    International Nuclear Information System (INIS)

    Thurber, J.A.; Olson, J.; Osborn, R.N.; Sommers, P.; Widrig, R.D.

    1985-08-01

    The Guidelines are intended to provide guidance to the user in preparing a written plan for a proposed nuclear organization and administration. The Guidelines allow for individual approaches to organizational structures to account for differences in plant size, number of operating units, number of plant sites, and the individual utility approach to providing technical support. These unique approaches, however, should meet the criteria of a reasoned, fully developed, and logically consistent focus on the user's organization in terms of organization of work, policies and procedures, staffing, and external relationships

  3. Autonomous Aircraft Operations using RTCA Guidelines for Airborne Conflict Management

    Science.gov (United States)

    Krishnamurthy, Karthik; Wing, David J.; Barmore, Bryan E.; Barhydt, Richard; Palmer, Michael T.; Johnson, Edward J.; Ballin, Mark G.; Eischeid, Todd M.

    2003-01-01

    A human-in-the-loop experiment was performed at the NASA Langley Research Center to study the feasibility of DAG-TM autonomous aircraft operations in highly constrained airspace. The airspace was constrained by a pair of special-use airspace (SUA) regions on either side of the pilot's planned route. Traffic flow management (TFM) constraints were imposed as a required time of arrival and crossing altitude at an en route fix. Key guidelines from the RTCA Airborne Conflict Management (ACM) concept were applied to autonomous aircraft operations for this experiment. These concepts included the RTCA ACM definitions of distinct conflict detection and collision avoidance zones, and the use of a graded system of conflict alerts for the flight crew. Three studies were conducted in the course of the experiment. The first study investigated the effect of hazard proximity upon pilot ability to meet constraints and solve conflict situations. The second study investigated pilot use of the airborne tools when faced with an unexpected loss of separation (LOS). The third study explored pilot interactions in an over-constrained conflict situation, with and without priority rules dictating who should move first. Detailed results from these studies were presented at the 5th USA/Europe Air Traffic Management R&D Seminar (ATM2003). This overview paper focuses on the integration of the RTCA ACM concept into autonomous aircraft operations in highly constrained situations, and provides an overview of the results presented at the ATM2003 seminar. These results, together with previously reported studies, continue to support the feasibility of autonomous aircraft operations.

  4. Role of operator response guidelines in CANDU 9 design program

    International Nuclear Information System (INIS)

    Jaitly, R.K.

    2000-01-01

    The CANDU 9 is a large version of the CANDU Pressurized Heavy Water Reactor (PHWR) system developed in Canada. With an electrical output of approximately 935 MWe, the CANDU 9 complements the established mid-size CANDU 6 (700 MWe) and makes use of proven technology updated with state of the art features resulting from ongoing development. The CANDU 9 builds on the reactor and process system designs of the operating Darlington and Bruce B plants, and incorporates a modified CANDU 6 station layout, as well as improved construction methods and operational features. A high level of standardization has always been a feature of CANDU reactors. This theme is emphasized in the CANDU 9; all key components (reactor core, steam generators, coolant pumps, pressure tubes, etc.) are of the same design as those proven in service in the operating CANDU power stations. Including Probabilistic Safety Assessment (PSA) as part of the CANDU 9 design process from the outset of the program was seen as key to ensuring completeness of safety related requirements. The PSA work provided an in-depth understanding of the plant response to various postulated accidents. As well, the time frame for recovery and the related operator actions were identified. This information together with AECL's experience in supporting the development of Emergency Operating Procedures (EOPs) for the operating CANDU reactors are the basis for preparation of CANDU 9 Operator Response Guidelines (ORGs). Technical content, format and human factors considerations adopted for the ORGs are such that these can be readily converted to EOPs. The scope of ORGs includes generic as well as event specific ORGs. This dual approach is required to provide defense-in-depth. This paper describes the process used to prepare ORGs for the CANDU 9 reactor and discusses important benefits gained from the application of ORGs as input to the control center design and future preparation of the EOPs. (author)

  5. OSART Guidelines. 2015 Edition. Reference Report for IAEA Operational Safety Review Teams (OSARTs)

    International Nuclear Information System (INIS)

    2016-01-01

    The IAEA works to provide a global nuclear safety and security framework for the protection of people and the environment from the effects of ionizing radiation, the minimization of the likelihood of accidents that could endanger life and property, and effective mitigation of the effects of any such events, should they occur. The strategic approach to achieving such a framework involves continual improvement in four areas: national and international safety infrastructures; the establishment and global acceptance of IAEA safety standards; an integrated approach to the provision for the application of the safety standards; and a global network of knowledge and experience. The IAEA Operational Safety Review Team (OSART) programme provides advice and assistance to Member States to enhance the safety of nuclear power plants during commissioning and operation. The OSART programme, initiated in 1982, is available to all Member States with nuclear power plants under commissioning or in operation. Conservative design, careful manufacture and sound construction are all prerequisites for the safe operation of nuclear power plants. However, the safety of the plant also depends ultimately on: sound management, policies, procedures, processes and practices; the capability and reliability of commissioning and operating personnel; comprehensive instructions; sound accident management and emergency preparedness; and adequate resources. Finally, a positive attitude and conscientiousness on the part of all staff in discharging their responsibilities is important to safety. The OSART programme is based on the safety standards applicable to nuclear power plants. IAEA safety standards reflect the consensus of Member States on nuclear safety matters. The reports of the International Nuclear Safety Group identify important current nuclear safety issues and also serve as references during an OSART review. The publication OSART Guidelines provides overall guidance on the conduct of OSART

  6. Guidelines for Distribution System Operators on Reactive Power Provision by Electric Vehicles in Low Voltage Grids

    DEFF Research Database (Denmark)

    Zecchino, Antonio; Marinelli, Mattia; Træholt, Chresten

    2017-01-01

    The increasing success of electric vehicles is bringing new technical challenges to power system operators. This work intends to provide guidelines for distribution system operators in terms of reactive power requirements when evaluating and authorizing electric vehicles supply equipment with fast...... the amount of reactive power that an individual electric vehicle is expected to provide when connected to a low voltage feeder, in order to benefit of the desired voltage rise effect in comparison to the case of unitary power factor....

  7. Regulatory principles, criteria and guidelines for site selection, design, construction and operation of uranium tailings retention systems

    International Nuclear Information System (INIS)

    Coady, J.R.; Henry, L.C.

    1978-01-01

    Principles, criteria and guidelines developed by the Atomic Energy Control Board for the management of uranium mill tailings are discussed. The application of these concepts is considered in relation to site selection, design and construction, operation and decommissioning of tailings retention facilities

  8. 32 CFR 231.11 - Guidelines.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 2 2010-07-01 2010-07-01 false Guidelines. 231.11 Section 231.11 National... PROCEDURES GOVERNING BANKS, CREDIT UNIONS AND OTHER FINANCIAL INSTITUTIONS ON DOD INSTALLATIONS Guidelines for Application of the Privacy Act to Financial Institution Operations § 231.11 Guidelines. (a) The...

  9. 10 CFR 960.4-1 - System guideline.

    Science.gov (United States)

    2010-01-01

    ... DEPARTMENT OF ENERGY GENERAL GUIDELINES FOR THE PRELIMINARY SCREENING OF POTENTIAL SITES FOR A NUCLEAR WASTE... at the site shall allow for the physical separation of radioactive waste from the accessible environment after closure in accordance with the requirements of 40 CFR part 191, subpart B, as implemented by...

  10. Closed cooling water chemistry guidelines revision

    International Nuclear Information System (INIS)

    McElrath, Joel; Breckenridge, Richard

    2014-01-01

    This second revision of the Closed Cooling Water Chemistry Guideline addresses the use of chemicals and monitoring methods to mitigate corrosion, fouling, and microbiological growth in the closed cooling-water (CCW) systems of nuclear and fossil-fueled power plants. This revision has been endorsed by the utility chemistry community and represents another step in developing a more proactive chemistry program to limit or control closed cooling system degradation with increased consideration of corporate resources and plant-specific design and operating concerns. These guidelines were developed using laboratory data, operating experience, and input from organizations and utilities within and outside of the United States of America. It is the intent of the Revision Committee that these guidelines are applicable to all nuclear and fossil-fueled generating stations around the world. A committee of industry experts—including utility specialists, Institute of Nuclear Power Operations representatives, water-treatment service-company representatives, consultants, a primary contractor, and EPRI staff—collaborated in reviewing available data on closed cooling-water system corrosion and microbiological issues. Recognizing that each plant owner has a unique set of design, operating, and corporate concerns, the Guidelines Committee developed a methodology for plant-specific optimization. The guideline provides the technical basis for a reasonable but conservative set of chemical treatment and monitoring programs. The use of operating ranges for the various treatment chemicals discussed in this guideline will allow a power plant to limit corrosion, fouling, and microbiological growth in CCW systems to acceptable levels. The guideline now includes closed cooling chemistry regimes proven successful in use in the international community. The guideline provides chemistry constraints for the use of phosphates control, as well as pure water with pH control. (author)

  11. Solid Waste Operations Complex W-113: Project cost estimate. Preliminary design report. Volume IV

    International Nuclear Information System (INIS)

    1995-01-01

    This document contains Volume IV of the Preliminary Design Report for the Solid Waste Operations Complex W-113 which is the Project Cost Estimate and construction schedule. The estimate was developed based upon Title 1 material take-offs, budgetary equipment quotes and Raytheon historical in-house data. The W-113 project cost estimate and project construction schedule were integrated together to provide a resource loaded project network

  12. General guidelines for recommendation of sites for nuclear waste repositories

    International Nuclear Information System (INIS)

    1983-01-01

    These guidelines were developed in accordance with the requirements of Section 112(a) of the Nuclear Waste Policy Act of 1982 for use by the Secretary of Energy in evaluating the suitability of sites for the development of repositories. The guidelines will be used for suitability evaluations and determinations made pursuant to Section 112(b) and any preliminary suitability determinations required by Section 114(f). The guidelines set forth in this Part are intended to complement the requirements set forth in the Act, 10 CFR Part 60, and 40 CFR Part 191. In applying these guidelines, the DOE will resolve any inconsistencies between these guidelines and the above documents in a manner determined by the DOE to most closely agree with the intent of the Act

  13. 2017 publication guidelines for structural modelling of small-angle scattering data from biomolecules in solution: an update.

    Science.gov (United States)

    Trewhella, Jill; Duff, Anthony P; Durand, Dominique; Gabel, Frank; Guss, J Mitchell; Hendrickson, Wayne A; Hura, Greg L; Jacques, David A; Kirby, Nigel M; Kwan, Ann H; Pérez, Javier; Pollack, Lois; Ryan, Timothy M; Sali, Andrej; Schneidman-Duhovny, Dina; Schwede, Torsten; Svergun, Dmitri I; Sugiyama, Masaaki; Tainer, John A; Vachette, Patrice; Westbrook, John; Whitten, Andrew E

    2017-09-01

    In 2012, preliminary guidelines were published addressing sample quality, data acquisition and reduction, presentation of scattering data and validation, and modelling for biomolecular small-angle scattering (SAS) experiments. Biomolecular SAS has since continued to grow and authors have increasingly adopted the preliminary guidelines. In parallel, integrative/hybrid determination of biomolecular structures is a rapidly growing field that is expanding the scope of structural biology. For SAS to contribute maximally to this field, it is essential to ensure open access to the information required for evaluation of the quality of SAS samples and data, as well as the validity of SAS-based structural models. To this end, the preliminary guidelines for data presentation in a publication are reviewed and updated, and the deposition of data and associated models in a public archive is recommended. These guidelines and recommendations have been prepared in consultation with the members of the International Union of Crystallography (IUCr) Small-Angle Scattering and Journals Commissions, the Worldwide Protein Data Bank (wwPDB) Small-Angle Scattering Validation Task Force and additional experts in the field.

  14. BWR emergency procedure guidelines

    International Nuclear Information System (INIS)

    Post, J.S.; Karner, E.F.; Stratman, R.A.

    1984-01-01

    This chapter describes plans for dealing with reactor accidents developed by the Boiling Water Reactor (BWR) Owners' Group in response to post-Three Mile Island US NRC requirements. The devised Emergency Procedure Guidelines (EPGs), applicable to all BWRs, are symptom-based rather than event-based. According to the EPGs, the operator does not need to identify what event is occurring in the plant in order to decide what action to take, but need only observe the symptoms (values and trends of key control parameters) which exist and take appropriate action to control these symptoms. The original objective was to provide reactor operator guidance in responding to a small break loss-of-coolant accident (LOCA), but subsequent revisions have included other types of reactor accidents. Topics considered include the reactor pressure vessel (RPV) control guideline, the primary containment control guideline, the secondary containment control guideline, the radioactivity release control guideline, multiple failures vs. the design basis, safe limits vs. technical specifications, the technical status, licensing, and implementation. The EPGs are based upon maintaining both adequate core cooling and primary containment integrity

  15. 28 CFR 23.30 - Funding guidelines.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Funding guidelines. 23.30 Section 23.30 Judicial Administration DEPARTMENT OF JUSTICE CRIMINAL INTELLIGENCE SYSTEMS OPERATING POLICIES § 23.30 Funding guidelines. The following funding guidelines shall apply to all Crime Control Act funded...

  16. Preliminary safety analysis report for the TFTR

    International Nuclear Information System (INIS)

    Lind, K.E.; Levine, J.D.; Howe, H.J.

    A Preliminary Safety Analysis Report has been prepared for the Tokamak Fusion Test Reactor. No accident scenarios have been identified which would result in exposures to on-site personnel or the general public in excess of the guidelines defined for the project by DOE

  17. 78 FR 48159 - Preliminary 2012 Effluent Guidelines Program Plan and 2011 Annual Effluent Guidelines Review Report

    Science.gov (United States)

    2013-08-07

    ... publish a preliminary plan in the odd numbered years and a final plan in the even numbered years. The... necessary before concluding the review of the three remaining point source categories: Pulp, Paper and... standards for the 2012 reviews. These methodologies included: Identifying pass-through pollutants in sewage...

  18. Draft Function Allocation Framework and Preliminary Technical Basis for Advanced SMR Concepts of Operations

    Energy Technology Data Exchange (ETDEWEB)

    Hugo, Jacques [Idaho National Lab. (INL), Idaho Falls, ID (United States); Forester, John [Idaho National Lab. (INL), Idaho Falls, ID (United States); Gertman, David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Joe, Jeffrey [Idaho National Lab. (INL), Idaho Falls, ID (United States); Medema, Heather [Idaho National Lab. (INL), Idaho Falls, ID (United States); Persensky, Julius [Idaho National Lab. (INL), Idaho Falls, ID (United States); Whaley, April [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2013-08-01

    This report presents preliminary research results from the investigation into the development of new models and guidance for Concepts of Operations in advanced small modular reactor (AdvSMR) designs. AdvSMRs are nuclear power plants (NPPs), but unlike conventional large NPPs that are constructed on site, AdvSMRs systems and components will be fabricated in a factory and then assembled on site. AdvSMRs will also use advanced digital instrumentation and control systems, and make greater use of automation. Some AdvSMR designs also propose to be operated in a multi-unit configuration with a single central control room as a way to be more cost-competitive with existing NPPs. These differences from conventional NPPs not only pose technical and operational challenges, but they will undoubtedly also have regulatory compliance implications, especially with respect to staffing requirements and safety standards.

  19. Crew aiding and automation: A system concept for terminal area operations, and guidelines for automation design

    Science.gov (United States)

    Dwyer, John P.

    1994-01-01

    This research and development program comprised two efforts: the development of guidelines for the design of automated systems, with particular emphasis on automation design that takes advantage of contextual information, and the concept-level design of a crew aiding system, the Terminal Area Navigation Decision Aiding Mediator (TANDAM). This concept outlines a system capable of organizing navigation and communication information and assisting the crew in executing the operations required in descent and approach. In service of this endeavor, problem definition activities were conducted that identified terminal area navigation and operational familiarization exercises addressing the terminal area navigation problem. Both airborne and ground-based (ATC) elements of aircraft control were extensively researched. The TANDAM system concept was then specified, and the crew interface and associated systems described. Additionally, three descent and approach scenarios were devised in order to illustrate the principal functions of the TANDAM system concept in relation to the crew, the aircraft, and ATC. A plan for the evaluation of the TANDAM system was established. The guidelines were developed based on reviews of relevant literature, and on experience gained in the design effort.

  20. Operational Earthquake Forecasting: Proposed Guidelines for Implementation (Invited)

    Science.gov (United States)

    Jordan, T. H.

    2010-12-01

    The goal of operational earthquake forecasting (OEF) is to provide the public with authoritative information about how seismic hazards are changing with time. During periods of high seismic activity, short-term earthquake forecasts based on empirical statistical models can attain nominal probability gains in excess of 100 relative to the long-term forecasts used in probabilistic seismic hazard analysis (PSHA). Prospective experiments are underway by the Collaboratory for the Study of Earthquake Predictability (CSEP) to evaluate the reliability and skill of these seismicity-based forecasts in a variety of tectonic environments. How such information should be used for civil protection is by no means clear, because even with hundredfold increases, the probabilities of large earthquakes typically remain small, rarely exceeding a few percent over forecasting intervals of days or weeks. Civil protection agencies have been understandably cautious in implementing formal procedures for OEF in this sort of “low-probability environment.” Nevertheless, the need to move more quickly towards OEF has been underscored by recent experiences, such as the 2009 L’Aquila earthquake sequence and other seismic crises in which an anxious public has been confused by informal, inconsistent earthquake forecasts. Whether scientists like it or not, rising public expectations for real-time information, accelerated by the use of social media, will require civil protection agencies to develop sources of authoritative information about the short-term earthquake probabilities. In this presentation, I will discuss guidelines for the implementation of OEF informed by my experience on the California Earthquake Prediction Evaluation Council, convened by CalEMA, and the International Commission on Earthquake Forecasting, convened by the Italian government following the L’Aquila disaster. (a) Public sources of information on short-term probabilities should be authoritative, scientific, open, and

  1. OSART guidelines - 2005 edition. Reference report for IAEA Operational Safety Review Teams (OSARTs)

    International Nuclear Information System (INIS)

    2005-01-01

    when exchanging ideas, at the working level, for enhancing safety. The OSART programme is based on the IAEA's Nuclear Safety Standard Series (Fundamentals, Requirements and Safety Guides) for nuclear power plants and the Basic Safety Standards for Radiation Protection. The Nuclear Safety Standards reflect the consensus of Member States on nuclear safety matters. The reports of the International Nuclear Safety Advisory Group, identifying important current nuclear safety issues also serve as references during an OSART review. The OSART Guidelines provide overall guidance for the experts to ensure the consistency and comprehensiveness of the operational safety review. Additional guidance and reference material prepared by the IAEA and the expertise of the OSART members contribute to the bases of the review. OSART reviews are performance oriented in that they accept different approaches to commissioning and operational safety that represent good practices and may contribute to ensuring a good safety record on the part of the operating organization. Recommendations are made on items of direct relevance to safety, whereas suggestions made might enhance plant safety indirectly but would certainly improve performance. Commendable good practices identified at plants are communicated to other plants where relevant in order to effect improvements. This revision of the OSART guidelines supersedes the 1994 Edition (IAEA-TECDOC-744)

  2. OSART guidelines - 2005 edition. Reference report for IAEA Operational Safety Review Teams (OSARTs)

    International Nuclear Information System (INIS)

    2007-01-01

    when exchanging ideas, at the working level, for enhancing safety. The OSART programme is based on the IAEA's Nuclear Safety Standard Series (Fundamentals, Requirements and Safety Guides) for nuclear power plants and the Basic Safety Standards for Radiation Protection. The Nuclear Safety Standards reflect the consensus of Member States on nuclear safety matters. The reports of the International Nuclear Safety Advisory Group, identifying important current nuclear safety issues also serve as references during an OSART review. The OSART Guidelines provide overall guidance for the experts to ensure the consistency and comprehensiveness of the operational safety review. Additional guidance and reference material prepared by the IAEA and the expertise of the OSART members contribute to the bases of the review. OSART reviews are performance oriented in that they accept different approaches to commissioning and operational safety that represent good practices and may contribute to ensuring a good safety record on the part of the operating organization. Recommendations are made on items of direct relevance to safety, whereas suggestions made might enhance plant safety indirectly but would certainly improve performance. Commendable good practices identified at plants are communicated to other plants where relevant in order to effect improvements. This revision of the OSART guidelines supersedes the 1994 Edition (IAEA-TECDOC-744)

  3. OSART guidelines - 2005 edition. Reference report for IAEA Operational Safety Review Teams (OSARTs)

    International Nuclear Information System (INIS)

    2008-01-01

    when exchanging ideas, at the working level, for enhancing safety. The OSART programme is based on the IAEA's Nuclear Safety Standard Series (Fundamentals, Requirements and Safety Guides) for nuclear power plants and the Basic Safety Standards for Radiation Protection. The Nuclear Safety Standards reflect the consensus of Member States on nuclear safety matters. The reports of the International Nuclear Safety Advisory Group, identifying important current nuclear safety issues also serve as references during an OSART review. The OSART Guidelines provide overall guidance for the experts to ensure the consistency and comprehensiveness of the operational safety review. Additional guidance and reference material prepared by the IAEA and the expertise of the OSART members contribute to the bases of the review. OSART reviews are performance oriented in that they accept different approaches to commissioning and operational safety that represent good practices and may contribute to ensuring a good safety record on the part of the operating organization. Recommendations are made on items of direct relevance to safety, whereas suggestions made might enhance plant safety indirectly but would certainly improve performance. Commendable good practices identified at plants are communicated to other plants where relevant in order to effect improvements. This revision of the OSART guidelines supersedes the 1994 Edition (IAEA-TECDOC-744)

  4. A novel attention training paradigm based on operant conditioning of eye gaze: Preliminary findings.

    Science.gov (United States)

    Price, Rebecca B; Greven, Inez M; Siegle, Greg J; Koster, Ernst H W; De Raedt, Rudi

    2016-02-01

    Inability to engage with positive stimuli is a widespread problem associated with negative mood states across many conditions, from low self-esteem to anhedonic depression. Though attention retraining procedures have shown promise as interventions in some clinical populations, novel procedures may be necessary to reliably attenuate chronic negative mood in refractory clinical populations (e.g., clinical depression) through, for example, more active, adaptive learning processes. In addition, a focus on individual difference variables predicting intervention outcome may improve the ability to provide such targeted interventions efficiently. To provide preliminary proof-of-principle, we tested a novel paradigm using operant conditioning to train eye gaze patterns toward happy faces. Thirty-two healthy undergraduates were randomized to receive operant conditioning of eye gaze toward happy faces (train-happy) or neutral faces (train-neutral). At the group level, the train-happy condition attenuated sad mood increases following a stressful task, in comparison to train-neutral. In individual differences analysis, greater physiological reactivity (pupil dilation) in response to happy faces (during an emotional face-search task at baseline) predicted decreased mood reactivity after stress. These Preliminary results suggest that operant conditioning of eye gaze toward happy faces buffers against stress-induced effects on mood, particularly in individuals who show sufficient baseline neural engagement with happy faces. Eye gaze patterns to emotional face arrays may have a causal relationship with mood reactivity. Personalized medicine research in depression may benefit from novel cognitive training paradigms that shape eye gaze patterns through feedback. Baseline neural function (pupil dilation) may be a key mechanism, aiding in iterative refinement of this approach. (c) 2016 APA, all rights reserved).

  5. Comparative Analyses on OPR1000 Steam Generator Tube Rupture Event Emergency Operational Guideline

    International Nuclear Information System (INIS)

    Lee, Sang Won; Bae, Yeon Kyoung; Kim, Hyeong Teak

    2006-01-01

    The Steam Generator Tube Rupture (SGTR) event is one of the important scenarios in respect to the radiation release to the environment. When the SGTR occurs, containment integrity is not effective because of the direct bypass of containment via the ruptured steam generator to the MSSV and MSADV. To prevent this path, the Emergency Operational Guideline of OPR1000 indicates the use of Turbine Bypass Valves (TBVs) as an effective means to depressurize the main steam line and prevent the lifting of MSSV. However, the TBVs are not operable when the offsite power is not available (LOOP). In this situation, the RCS cool-down is achieved by opening the both intact and ruptured SG MSADV. But this action causes the large amount of radiation release to the environment. To minimize the radiation release to the environment, KSNP EOG adopts the improved strategy when the SGTR concurrently with LOOP is occurred. However, these procedures show some duplicated procedure and branch line that might confusing the operator for optimal recovery action. So, in this paper, the comparative analysis on SGTR and SGTR with LOOP is performed and optimized procedure is proposed

  6. Guidelines for selecting codes for ground-water transport modeling of low-level waste burial sites. Volume 1. Guideline approach

    Energy Technology Data Exchange (ETDEWEB)

    Simmons, C.S.; Cole, C.R.

    1985-05-01

    This document was written for the National Low-Level Waste Management Program to provide guidance for managers and site operators who need to select ground-water transport codes for assessing shallow-land burial site performance. The guidance given in this report also serves the needs of applications-oriented users who work under the direction of a manager or site operator. The guidelines are published in two volumes designed to support the needs of users having different technical backgrounds. An executive summary, published separately, gives managers and site operators an overview of the main guideline report. This volume includes specific recommendations for decision-making managers and site operators on how to use these guidelines. The more detailed discussions about the code selection approach are provided. 242 refs., 6 figs.

  7. Guidelines for selecting codes for ground-water transport modeling of low-level waste burial sites. Volume 1. Guideline approach

    International Nuclear Information System (INIS)

    Simmons, C.S.; Cole, C.R.

    1985-05-01

    This document was written for the National Low-Level Waste Management Program to provide guidance for managers and site operators who need to select ground-water transport codes for assessing shallow-land burial site performance. The guidance given in this report also serves the needs of applications-oriented users who work under the direction of a manager or site operator. The guidelines are published in two volumes designed to support the needs of users having different technical backgrounds. An executive summary, published separately, gives managers and site operators an overview of the main guideline report. This volume includes specific recommendations for decision-making managers and site operators on how to use these guidelines. The more detailed discussions about the code selection approach are provided. 242 refs., 6 figs

  8. Draft Function Allocation Framework and Preliminary Technical Basis for Advanced SMR Concepts of Operations

    Energy Technology Data Exchange (ETDEWEB)

    Jacques Hugo; John Forester; David Gertman; Jeffrey Joe; Heather Medema; Julius Persensky; April Whaley

    2013-04-01

    This report presents preliminary research results from the investigation in to the development of new models and guidance for concepts of operations (ConOps) in advanced small modular reactor (aSMR) designs. In support of this objective, three important research areas were included: operating principles of multi-modular plants, functional allocation models and strategies that would affect the development of new, non-traditional concept of operations, and the requiremetns for human performance, based upon work domain analysis and current regulatory requirements. As part of the approach for this report, we outline potential functions, including the theoretical and operational foundations for the development of a new functional allocation model and the identification of specific regulatory requirements that will influence the development of future concept of operations. The report also highlights changes in research strategy prompted by confirmationof the importance of applying the work domain analysis methodology to a reference aSMR design. It is described how this methodology will enrich the findings from this phase of the project in the subsequent phases and help in identification of metrics and focused studies for the determination of human performance criteria that can be used to support the design process.

  9. Failure of Magnetic Fluid Seals Operating in Water: Preliminary Conclusions

    Directory of Open Access Journals (Sweden)

    Matuszewski Leszek

    2017-06-01

    Full Text Available The article analyses properties of magnetic fluid seals installed in rotary sealing nodes which operate in the utility water environment. Seals of this type have been examined as a possible solution to the problem with ship manoeuvring propulsion sealing. The present analysis bases on laboratory durability tests of magnetic fluid seals exposed to longterm utility water loads, at different water pressures and shaft revolutions. The basic seal durability criterion was the number of revolutions made by the sealing node shaft until the appearance of water tightness loss (leakage. It was found that the main factor leading to the wear of the seal is the relative speed of the magnetic fluid with respect to that of the utility water, and this process is heavily affected by the pressure acting on the seal. The reported test results are presented in the form of diagrams showing the seal durability (time until water tightness loss as a function of rotational speed. The curves shown in the diagrams are regular, with two different rotational speed ranges: the highspeed range, when the tightness loss is relatively fast, and the low-speed range, with a clear tendency to prolong the seal lifetime. These diagrams were given the name of durability curves of the MF seal operating in water. The results of the performed tests suggest formal similarity between the experimental data distribution concerning tightness loss processes occurring in magnetic fluid seals operating in water environment and metal fatigue processes. The article proposes a preliminary simplified durability model to describe the examined phenomenon.

  10. Introducing guidelines into clinical practice.

    Science.gov (United States)

    Fowkes, F G; Roberts, C J

    1984-04-01

    The impetus for guidelines of practice has been accelerated by a worldwide trend towards insurance based systems of health care. In the past it has been the tradition for the clinician to order all the diagnostic procedures that conceivably might help to clarify what is wrong with a patient, or what course of treatment should be followed. This traditional view ignores the stubborn economic reality that resources are finite and that it is no longer possible to be both endlessly generous and continually fair. Making judgements about the need for, and value of, services now forms an important part of coping with this problem. Clinical practice has to strive to be as safe as possible and to produce a given benefit at a socially acceptable cost. Guidelines are recommendations, preferably developed by clinicians themselves, which describe how and when individual clinical activities should be offered in order to achieve these objectives. Utilisation review of current practice is a valuable source of information for the development of guidelines. In the United Kingdom the Royal College of Radiologists attempted to do this in connection with the use of pre-operative chest X-rays. In 1979 they published the findings of a multicentre review of 10,619 consecutive cases of elective non-cardiopulmonary surgery undertaken in 8 centres throughout the United Kingdom. Substantial variations were found in national practice. Use of pre-operative chest X-rays varied from 11.5% of patients in one centre to 54.2% of patients in another centre. The study also found that the chest X-ray report did not seem to have much influence on the decision to operate nor on the decision to use inhalation anaesthesia. The College study failed to find "any evidence at all for the effectiveness of pre-operative chest X-ray when used routinely" and it was estimated that even if the procedure was 10% effective the costs of avoiding one death would be approximately 1 million pounds. These findings provided

  11. ITER operating limit definition criteria

    International Nuclear Information System (INIS)

    Ciattaglia, S.; Barabaschi, P.; Carretero, J.A.; Chiocchio, S.; Hureau, D.; Girard, J.Ph.; Gordon, C.; Portone, A.; Rodrigo, L. Rodriguez; Roldan, C.; Saibene, G.; Uzan-Elbez, J.

    2009-01-01

    The operating limits and conditions (OLCs) are operating parameters and conditions, chosen among all system/components, which, together, define the domain of the safe operation of ITER in all foreseen ITER states (operation, maintenance, commissioning). At the same time they are selected to guarantee the required operation flexibility which is a critical factor for the success of an experimental machine such as ITER. System and components that are important for personnel or public safety (safety important class, SIC) are identified considering their functional importance in the overall plant safety analysis. SIC classification has to be presented already in the preliminary safety analysis report and approved by the licensing authority before manufacturing and construction. OLCs comprise the safety limits that, if exceeded, could result in a potential safety hazard, the relevant settings that determine the intervention of SIC systems, and the operational limits on equipment which warn against or stop a functional deviation from a planned operational status that could challenge equipment and functions. Some operational conditions, e.g. in-Vacuum Vessel (VV) radioactive inventories, will be controlled through procedures. Operating experience from present tokamaks, in particular JET, and from nuclear plants, is considered to the maximum possible extent. This paper presents the guidelines for the development of the ITER OLCs with particular reference to safety limits.

  12. Design Guidelines and Criteria for User/Operator Transactions with Battlefield Automated Systems. Volume III-A. Human Factors Analyses of User/ Operator Transactions with TACFIRE - The Tactical Fire Direction System

    Science.gov (United States)

    1981-02-01

    7. Reseaarch Product 81-26 - DESIGN GUIDELINES AND CRITERIA FOR USER/ I;. I’OPERATOR TRANSACTIONS WITH BATTLEFIELD AUTOMIATED SYSTEMS I’ /HVtAN...FACTORS XWLYSES :’F K~R/ OPERATOR TRANSACTIONS WTHT TACFIRE - THE TACTICAL FIRE DiRECTION SY2T3EM A HUMAN FACTORS TECHNICAL AREA L~h~h K L-J 1’ U~~i~ ll...Battlefield Auto- Inter : Oct 1979-Feb 1981 mated Systems Volume III-A: Human Factors 4t C/ Analyses of User/Operator Transactions with 6. PERFORMING

  13. [Quality indicators for National Disease Management Guidelines using the example of the National Disease Management Guideline for "Chronic Heart Failure"].

    Science.gov (United States)

    Nothacker, Monika Judith; Langer, Thomas; Weinbrenner, Susanne

    2011-01-01

    Together with an expert committee a structured approach to determining quality indicators for National Disease Management Guidelines has been developed. The key steps of this approach include: introducing guideline authors to the methodology at an early stage of the process of guideline development, pre-selecting recommendations of the guideline which are potentially measurable by means of quality indicators, assessing the potentially measurable quality indicators in written form using five criteria (including their importance for the health care system and clarity of definitions) and approving them in a formal consensus process. For lack of a database these quality indicators must be regarded as preliminary. For the National Disease Management Guideline "Chronic Heart Failure" nine rate-based indicators have been chosen. The indicators correspond to important strong recommendations (grade of recommendation: A) from the fields of diagnosis (two), general therapeutic strategy (two), specific treatment (three), clinical monitoring (one) and co-ordination of care (one). In a second step, the quality indicators have to be validated within a pilot project. The determination and assessment of the potential quality indicators have revealed room for improvement of guideline development. In particular, there is a need for more health care data and for specification of recommendations.

  14. Preliminary estimation of the dose rates of the operation room of the RPR radioisotope cell

    International Nuclear Information System (INIS)

    Rocha, A.C.S.; Silva, J.J.G.; Pina, J.L.S. de; Fajardo, P.W.

    1986-07-01

    During the preliminary studies, about the installations layout of a radioisotope production reactor, the possibility of construction of a radioisotope cell at the reactor building has been investigated. The decisions about that construction has considered mainly the level of the radiation dose over the cell operator. The dose rate has been calculated based on: neutron flux and gamma radiation from fission products and activation materials inside the reactor; volatile fission products such as noble gases and iodides; tritium form ternary fission. The objective was calculate the radiation dose over the cell operator during a journey of 8 hours of work per day. For those calculations some data have been obtained from the Angra-3 reactor. (author)

  15. Proposal of a post-prostatectomy clinical target volume based on pre-operative MRI: volumetric and dosimetric comparison to the RTOG guidelines

    International Nuclear Information System (INIS)

    Croke, Jennifer; Maclean, Jillian; Nyiri, Balazs; Li, Yan; Malone, Kyle; Avruch, Leonard; Kayser, Cathleen; Malone, Shawn

    2014-01-01

    Recurrence rates following radiotherapy for prostate cancer in the post-operative adjuvant or salvage setting remain substantial. Previous work from our institution demonstrated that published prostate bed CTV guidelines frequently do not cover the pre-operative MRI defined prostate. Inadequate target delineation may contribute to the high recurrence rates, but increasing target volumes may increase dose to organs at risk. We propose guidelines for delineating post-prostatectomy target volumes based upon an individual’s co-registered pre-operative MRI. MRI-based CTVs and PTVs were compared to those created using the RTOG guidelines in 30 patients. Contours were analysed in terms of absolute volume, intersection volume (Jaccard Index) and the ability to meet the RADICALS and QUANTEC rectal and bladder constraints (tomotherapy IMRT plans with PTV coverage of V98% ≥98%). CTV MRI was a mean of 18.6% larger than CTV RTOG: CTV MRI mean 138 cc (range 72.3 - 222.2 cc), CTV RTOG mean 116.3 cc (range 62.1 - 176.6 cc), (p < 0.0001). The difference in mean PTV was only 4.6%: PTV MRI mean 386.9 cc (range 254.4 – 551.2), PTV RTOG mean 370 cc (range 232.3 - 501.6) (p = 0.05). The mean Jaccard Index representing intersection volume between CTVs was 0.72 and 0.84 for PTVs. Both criteria had a similar ability to meet rectal and bladder constraints. Rectal DVH: 77% of CTV RTOG cases passed all RADICALS criteria and 37% all QUANTEC criteria; versus 73% and 40% for CTV MRI (p = 1.0 for both). Bladder DVH; 47% of CTV RTOG cases passed all RADICALS criteria and 67% all QUANTEC criteria, versus 57% and 60% for CTV MRI (p = 0.61for RADICALS, p = 0.79 for QUANTEC). CTV MRI spares more of the lower anterior bladder wall than CTV RTOG but increases coverage of the superior lateral bladder walls. CTV contours based upon the patient’s co-registered pre-operative MRI in the post-prostatectomy setting may improve coverage of the individual’s prostate bed without substantially increasing

  16. Water chemistry guidelines for BWRs

    International Nuclear Information System (INIS)

    Bilanin, W.J.; Jones, R.L.; Welty, C.S.

    1984-01-01

    Guidelines for BWR water chemistry control have been prepared by a committee of experienced utility industry personnel sponsored by the BWR Owners Group on IGSCC Research and coordinated by the Electric Power Research Institute. The guidelines are based on extensive plant operational experience and laboratory research data. The purpose of the guidelines is to provide guidance to the electric utility industry on water chemistry control to help reduce corrosion, especially stress corrosion cracking, in boiling water reactors

  17. Advanced human-system interface design review guidelines

    International Nuclear Information System (INIS)

    O'Hara, J.M.

    1990-01-01

    Advanced, computer-based, human-system interface designs are emerging in nuclear power plant (NPP) control rooms. These developments may have significant implications for plant safety in that they will greatly affect the ways in which operators interact with systems. At present, however, the only guidance available to the US Nuclear Regulatory Commission (NRC) for the review of control room-operator interfaces, NUREG-0700, was written prior to these technological changes and is thus not designed to address them. The objective of the project reported in this paper is to develop an Advanced Control Room Design Review Guideline for use in performing human factors reviews of advanced operator interfaces. This guideline will be implemented, in part, as a portable, computer-based, interactive document for field use. The paper describes the overall guideline development methodology, the present status of the document, and the plans for further guideline testing and development. 21 refs., 3 figs

  18. Condensate polishing guidelines for PWR and BWR plants

    International Nuclear Information System (INIS)

    Robbins, P.; Crinigan, P.; Graham, B.; Kohlmann, R.; Crosby, C.; Seager, J.; Bosold, R.; Gillen, J.; Kristensen, J.; McKeen, A.; Jones, V.; Sawochka, S.; Siegwarth, D.; Keeling, D.; Polidoroff, T.; Morgan, D.; Rickertsen, D.; Dyson, A.; Mills, W.; Coleman, L.

    1993-03-01

    Under EPRI sponsorship, an industry committee, similar in form and operation to other guideline committees, was created to develop Condensate Polishing Guidelines for both PWR and BWR systems. The committee reviewed the available utility and water treatment industry experience on system design and performance and incorporated operational and state-of-the-art information into document. These guidelines help utilities to optimize present condensate polisher designs as well as be a resource for retrofits or new construction. These guidelines present information that has not previously been presented in any consensus industry document. The committee generated guidelines that cover both deep bed and powdered resin systems as an integral part of the chemistry of PWR and BWR plants. The guidelines are separated into sections that deal with the basis for condensate polishing, system design, resin design and application, data management and performance and management responsibilities

  19. 75 FR 75486 - Maritime Security Directive 104-6 (Rev. 4); Guidelines for U.S. Vessels Operating in High Risk...

    Science.gov (United States)

    2010-12-03

    ... Directive 104-6 (Rev. 4); Guidelines for U.S. Vessels Operating in High Risk Waters AGENCY: Coast Guard, DHS... Maritime Transportation Security Act (MTSA) on international voyages through or in designated high risk... MARSEC Directives are available at your local Captain of the Port (COTP) office. Phone numbers and...

  20. Assessing the effectiveness of a guideline recommendation for pre-operative radiochemotherapy in rectal cancer

    International Nuclear Information System (INIS)

    Manchon-Walsh, Paula; Borras, Josep Maria; Espinas, Josep Alfons; Aliste, Luisa

    2011-01-01

    Aim: To ascertain the degree of adherence to the guideline recommendation on pre-operative RT/ChT for stage-II and -III patients in Catalonian public hospitals, and its impact on local recurrence among rectal cancer patients. Methods: Data were derived from a multicentre retrospective cohort study of patients who underwent curative-intent surgery for primary rectal cancer at Catalonian public hospitals in 2005 and 2007. Results: The study covered 1229 patients with TNM stage-II or -III primary rectal cancer. Of these patients, 54.5% underwent pre-operative RT/ChT; 14.9% underwent post-operative RT (± chemotherapy); and 30.6% did not undergo any RT. The crude local recurrence rate at 2 years was 4.1% and the crude distant recurrence rate at 2 years was 6.5%. The results of the univariate analyses showed a local-recurrence hazard ratio of 1.84 for the group of patients that received no RT versus the group that received pre-operative RT/ChT (p < 0.01). Conclusions: This is the first population-based study in Catalonia to support the use of pre-operative RT/ChT in rectal cancer patients because, in line with the results of population-based studies reported from other countries, its application, compared to non-application of RT, was found to lead to a clear reduction in the probability of local recurrence.

  1. Guidelines for authorities and operators from the EURATOM regulation according to nuclear safety

    International Nuclear Information System (INIS)

    Karpenstein, Ulrich

    2010-01-01

    At 22nd July, 2009 the guideline 2009/71/EURATOM on a community framework for the nuclear security of nuclear installations comes into effect. A lot of regulations of this guideline intervene very deeply in the competencies of the member states. In acknowledgment of the national responsibility for nuclear security, the guideline grants large free space to the member states. Thereby, the guideline aims at a general legal framework and a mutual learning process off.

  2. Preliminary guidelines for electricity distributor conservation and demand management activities : a guide for conservation and demand management investment

    International Nuclear Information System (INIS)

    2004-01-01

    In May 2004, electricity distributors in Ontario were asked to submit deferral accounts to the Ontario Energy Board to track expenditures on conservation and demand management initiatives. The deferral accounts must be established before the distributor could recover the costs through the next installment of the allowable return on equity in March 2004. The Board will determine the appropriateness of the actual expenditures. These guidelines offer short-term assistance to distributors in establishing conservation and demand management plans and initiatives. The following specific measures may be supported by the Board: energy efficiency; operational changes to smart control systems; load management measures which facilitate interruptible and dispatchable loads, dual fuel applications, thermal storage and demand response; fuel switching measures; programs targeted to low income and hard to reach consumers; and, distributed energy options such as tri-generation, cogeneration, ground source heat pumps, wind and biomass systems. These guidelines described the regulatory treatment of conservation and demand management investments along with cost effectiveness, allocation of costs, monitoring, evaluation, and implementation. 1 appendix

  3. Guidelines and Ethical Considerations for Assessment Center Operations: International Task Force on Assessment Center Guidelines.

    Science.gov (United States)

    Public Personnel Management, 2000

    2000-01-01

    This update of the International Personnel Management Association's guidelines for organizational psychologists, human resource management specialists, and others addresses elements of assessment centers, policy statements, assessor training, informed participation, and participants' rights. (SK)

  4. Guideline for Bayesian Net based Software Fault Estimation Method for Reactor Protection System

    International Nuclear Information System (INIS)

    Eom, Heung Seop; Park, Gee Yong; Jang, Seung Cheol

    2011-01-01

    The purpose of this paper is to provide a preliminary guideline for the estimation of software faults in a safety-critical software, for example, reactor protection system's software. As the fault estimation method is based on Bayesian Net which intensively uses subjective probability and informal data, it is necessary to define formal procedure of the method to minimize the variability of the results. The guideline describes assumptions, limitations and uncertainties, and the product of the fault estimation method. The procedure for conducting a software fault-estimation method is then outlined, highlighting the major tasks involved. The contents of the guideline are based on our own experience and a review of research guidelines developed for a PSA

  5. Continuity of operations planning in college athletic programs: The case for incorporating Federal Emergency Management Guidelines.

    Science.gov (United States)

    Hall, Stacey A; Allen, Brandon L; Phillips, Dennis

    2016-01-01

    College athletic departments have a responsibility to provide a safe environment for student-athletes; however, most colleges do not have a crisis management plan that includes procedures for displaced student-athletes or alternate facilities to perform athletic events. Continuity of operations planning ensures athletic programs are equipped to maintain essential functions during, or shortly after, a disruption of operations due to possible hazards. Previous studies have identified a lack of emergency preparedness and continuity planning in college athletic departments. The purpose of this article is to illustrate in detail one approach to disaster planning for college athletic departments, namely the Federal Emergency Management Agency (FEMA) continuity of operations framework. By adhering to FEMA guidelines and promoting a best practices model, athletic programs can effectively plan to address potential hazards, as well as protect the organization's brand, image, and financial sustainability after a crisis event.

  6. Optimisation of small-scale hydropower using quality assurance methods - Preliminary project; Vorprojekt: Optimierung von Kleinwasserkraftwerken durch Qualitaetssicherung. Programm Kleinwasserkraftwerke

    Energy Technology Data Exchange (ETDEWEB)

    Hofer, S.; Staubli, T.

    2006-11-15

    This comprehensive final report for the Swiss Federal Office of Energy (SFOE) presents the results of a preliminary project that examined how quality assurance methods can be used in the optimisation of small-scale hydropower projects. The aim of the project, to use existing know-how, experience and synergies, is examined. Discrepancies in quality and their effects on production prices were determined in interviews. The paper describes best-practice guidelines for the quality assurance of small-scale hydro schemes. A flow chart describes the various steps that have to be taken in the project and realisation work. Information collected from planners and from interviews made with them are presented along with further information obtained from literature. The results of interviews concerning planning work, putting to tender and the construction stages of these hydro schemes are presented and commented on. Similarly, the operational phase of such power plant is also examined, including questions on operation and guarantees. The aims of the follow-up main project - the definition of a tool and guidelines for ensuring quality - are briefly reviewed.

  7. VGB primary and secondary side water chemistry guidelines for PWR plants

    International Nuclear Information System (INIS)

    Neder, H.; Wolter, D.; Staudt, U.

    2007-01-01

    The recent revision of the VGB Water Chemistry Guidelines was issued in 2005 and published in the second half of 2006. These guidelines are based on the primary and secondary side operating chemistry experience with all Siemens designed pressurized water reactors gained since the beginning of the 1980s. These guidelines cover For the primary side chemistry Modified lithium boron chemistry, Zinc chemistry for dose rate reduction, Enriched boric acid (EBA) chemistry for high duty core design For the secondary side chemistry High all-volatile treatment (AVT) chemistry (high pH operation) Oxygen injection in the secondary side Especially for the secondary side chemistry, compared with the water chemistry guidelines of other organizations worldwide, these Guidelines are less stringent, providing more operational flexibility to the plant operation, and can be applied for all new designs of steam generators with egg-crates or broached hole tube supports and with I 690TT or I 800 tubing materials. This paper gives an overview of the 2006 revision of the VGB Water Chemistry Guidelines for PWR plants and describes the fundamental goals of water chemistry operation strategies. In addition, the reasons for the selected control parameters and action levels, to achieve an adequate plant performance, are presented based on the operating experience. (orig.)

  8. Advanced human-system interface design review guideline. General evaluation model, technical development, and guideline description

    Energy Technology Data Exchange (ETDEWEB)

    O`Hara, J.M.

    1994-07-01

    Advanced control rooms will use advanced human-system interface (HSI) technologies that may have significant implications for plant safety in that they will affect the operator`s overall role in the system, the method of information presentation, and the ways in which operators interact with the system. The U.S. Nuclear Regulatory Commission (NRC) reviews the HSI aspects of control rooms to ensure that they are designed to good human factors engineering principles and that operator performance and reliability are appropriately supported to protect public health and safety. The principal guidance available to the NRC, however, was developed more than ten years ago, well before these technological changes. Accordingly, the human factors guidance needs to be updated to serve as the basis for NRC review of these advanced designs. The purpose of this project was to develop a general approach to advanced HSI review and the human factors guidelines to support NRC safety reviews of advanced systems. This two-volume report provides the results of the project. Volume I describes the development of the Advanced HSI Design Review Guideline (DRG) including (1) its theoretical and technical foundation, (2) a general model for the review of advanced HSIs, (3) guideline development in both hard-copy and computer-based versions, and (4) the tests and evaluations performed to develop and validate the DRG. Volume I also includes a discussion of the gaps in available guidance and a methodology for addressing them. Volume 2 provides the guidelines to be used for advanced HSI review and the procedures for their use.

  9. Preliminary Validation of the Small Aircraft Transportation System Higher Volume Operations (SATS HVO) Concept

    Science.gov (United States)

    Williams, Daniel; Consiglio, Maria; Murdoch, Jennifer; Adams, Catherine

    2004-01-01

    This document provides a preliminary validation of the Small Aircraft Transportation System (SATS) Higher Volume Operations (HVO) concept for normal conditions. Initial results reveal that the concept provides reduced air traffic delays when compared to current operations without increasing pilot workload. Characteristic to the SATS HVO concept is the establishment of a newly defined area of flight operations called a Self-Controlled Area (SCA) which would be activated by air traffic control (ATC) around designated non-towered, non-radar airports. During periods of poor visibility, SATS pilots would take responsibility for separation assurance between their aircraft and other similarly equipped aircraft in the SCA. Using onboard equipment and simple instrument flight procedures, they would then be better able to approach and land at the airport or depart from it. This concept would also require a new, ground-based automation system, typically located at the airport that would provide appropriate sequencing information to the arriving aircraft. Further validation of the SATS HVO concept is required and is the subject of ongoing research and subsequent publications.

  10. Main-coolant-pump shaft-seal guidelines. Volume 1. Maintenance-manual guidelines. Final report

    International Nuclear Information System (INIS)

    Fair, C.E.; Greer, A.O.

    1983-03-01

    This report presents a set of guidelines and a listing of information and data which should be included in maintenance manuals and procedures for Main Coolant Pump Shaft Seals. The noted guidelines and data listing are developed from EPRI sponsored nuclear plant seal operating experience studies. The maintenance oriented results of the most recent such study is summarized. The shaft seal and its auxiliary supporting systems are discussed from both technical and maintenance related viewpoints

  11. Medical guidelines for the patient: introducing the life assistance protocols.

    Science.gov (United States)

    Domínguez, David; Fernández, Carlos; Meneu, Teresa; Mocholí, Juan Bautista; Serafin, Riccardo

    2008-01-01

    This paper introduces our preliminary results in the modeling of Life Assistance Protocols, a new vision of medical guidelines and protocols through the lenses of p-Health. In this context the patient's role in the process is emphasized, the actions to be performed less defined and not only clinical situations considered, but also healthier lifestyle promotion processes accounted for, where the person's preferences and motivations play a key role. We propose a complete framework, balancing on classical clinical guideline models and covering both the theoretical and the practical aspects of the problem, describing it from conceptualization to the execution environment.

  12. 76 FR 2402 - Maritime Security Directive 104-6 (Rev 5); Guidelines for U.S. Vessels Operating in High Risk Waters

    Science.gov (United States)

    2011-01-13

    ... Directive 104-6 (Rev 5); Guidelines for U.S. Vessels Operating in High Risk Waters AGENCY: Coast Guard, DHS... designated high risk waters, and provides additional counter-piracy guidance and mandatory measures for these... MARSEC Directives are available at your local Captain of the Port (COTP) office. Phone numbers and...

  13. Index-TB Guidelines: Guidelines on extrapulmonary tuberculosis for India

    Science.gov (United States)

    Sharma, Surendra K.; Ryan, H.; Khaparde, Sunil; Sachdeva, K. S.; Singh, Achintya D.; Mohan, Alladi; Sarin, Rohit; Paramasivan, C N; Kumar, Prahlad; Nischal, Neeraj; Khatiwada, Saurav; Garner, Paul; Tharyan, Prathap

    2017-01-01

    Extrapulmonary tuberculosis (EPTB) is frequently a diagnostic and therapeutic challenge. It is a common opportunistic infection in people living with HIV/AIDS and other immunocompromised states such as diabetes mellitus and malnutrition. There is a paucity of data from clinical trials in EPTB and most of the information regarding diagnosis and management is extrapolated from pulmonary TB. Further, there are no formal national or international guidelines on EPTB. To address these concerns, Indian EPTB guidelines were developed under the auspices of Central TB Division and Directorate of Health Services, Ministry of Health and Family Welfare, Government of India. The objective was to provide guidance on uniform, evidence-informed practices for suspecting, diagnosing and managing EPTB at all levels of healthcare delivery. The guidelines describe agreed principles relevant to 10 key areas of EPTB which are complementary to the existing country standards of TB care and technical operational guidelines for pulmonary TB. These guidelines provide recommendations on three priority areas for EPTB: (i) use of Xpert MTB/RIF in diagnosis, (ii) use of adjunct corticosteroids in treatment, and (iii) duration of treatment. The guidelines were developed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) criteria, which were evidence based, and due consideration was given to various healthcare settings across India. Further, for those forms of EPTB in which evidence regarding best practice was lacking, clinical practice points were developed by consensus on accumulated knowledge and experience of specialists who participated in the working groups. This would also reflect the needs of healthcare providers and develop a platform for future research. PMID:28862176

  14. Evaluation of TCOM/HBOT practice guideline for the treatment of foot burns occurring in diabetic patients.

    Science.gov (United States)

    Jones, Larry M; Rubadue, Christopher; Brown, Nicole V; Khandelwal, Sorabh; Coffey, Rebecca A

    2015-05-01

    A multidisciplinary team developed an evidence-based guideline for the management of foot burns occurring in diabetic patients that included transcutaneous oxygen measurements (TCOM) and application of hyperbaric oxygen therapy (HBOT) to selected patients. This report represents an evaluation of preliminary TCOM/HBOT data. This is a retrospective review of patients with diabetes mellitus (DM) who were admitted to a single American Burn Association (ABA) verified burn center for the treatment of foot burns. Patients were treated via the guideline if they were over the age of 16, admitted for the initial care of burns involving the feet between 4/01/2012 and 7/22/2013, and had a known or new diagnosis of DM. Eighteen patients were treated according to the guideline, 14 men and 4 women. Average age was 54 years+14.78. Average BMI was 30.63+6.34. Median burn size was 0.88% TBSA (median partial thickness of 1% and median full thickness of 0.5%). The average HbA1c was 9.08+2.42. Seven patients received pre-operative HBOT, two received post-operative HBOT and three patients healed their wounds with HBOT alone. Average hospital length of stay was 13.39 days+9.94 and was significantly longer for the group receiving HBOT. Admission HbA1c was not a predictor of the need for HBOT. While TCOM/HBOT therapy has not been widely applied to the management of diabetic foot burns, the use of an evidence-based guideline incorporating TCOM/HBOT can provide a systematic way to evaluate the patients' microcirculation and ability to heal burns of the foot. The incorporation of TCOM determination and application of HBOT in selected patients with DM and burns of the feet warrant continued study. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.

  15. 23 CFR 645.109 - Preliminary engineering.

    Science.gov (United States)

    2010-04-01

    ... 23 Highways 1 2010-04-01 2010-04-01 false Preliminary engineering. 645.109 Section 645.109 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION ENGINEERING AND TRAFFIC OPERATIONS UTILITIES Utility Relocations, Adjustments, and Reimbursement § 645.109 Preliminary engineering. (a) As...

  16. Advanced human-system interface design review guideline. Evaluation procedures and guidelines for human factors engineering reviews

    Energy Technology Data Exchange (ETDEWEB)

    O`Hara, J.M.; Brown, W.S. [Brookhaven National Lab., Upton, NY (United States); Baker, C.C.; Welch, D.L.; Granda, T.M.; Vingelis, P.J. [Carlow International Inc., Falls Church, VA (United States)

    1994-07-01

    Advanced control rooms will use advanced human-system interface (HSI) technologies that may have significant implications for plant safety in that they will affect the operator`s overall role in the system, the method of information presentation, and the ways in which operators interact with the system. The U.S. Nuclear Regulatory Commission (NRC) reviews the HSI aspects of control rooms to ensure that they are designed to good human factors engineering principles and that operator performance and reliability are appropriately supported to protect public health and safety. The principal guidance available to the NRC, however, was developed more than ten years ago, well before these technological changes. Accordingly, the human factors guidance needs to be updated to serve as the basis for NRC review of these advanced designs. The purpose of this project was to develop a general approach to advanced HSI review and the human factors guidelines to support. NRC safety reviews of advanced systems. This two-volume report provides the results of the project. Volume I describes the development of the Advanced HSI Design Review Guideline (DRG) including (1) its theoretical and technical foundation, (2) a general model for the review of advanced HSIs, (3) guideline development in both hard-copy and computer-based versions, and (4) the tests and evaluations performed to develop and validate the DRG. Volume I also includes a discussion of the gaps in available guidance and a methodology for addressing them. Volume 2 provides the guidelines to be used for advanced HSI review and the procedures for their use.

  17. Standing operating procedures for developing acute exposure guideline levels for hazardous chemicals

    National Research Council Canada - National Science Library

    National Research Council (U.S.). Subcommittee on Acute Exposure Guideline Levels

    2001-01-01

    ... Exposure Guideline Levels for Hazardous Chemicals Subcommittee on Acute Exposure Guideline Levels Committee on Toxicology Board on Environmental Studies and Toxicology Commission on Life Sciences National Research Council NATIONAL ACADEMY PRESS Washington, D.C. i Copyrightthe cannot be not from book, paper however, version for formatting, origina...

  18. Treatise on water hammer in hydropower standards and guidelines

    International Nuclear Information System (INIS)

    Bergant, A; Mazij, J; Karney, B; Pejović, S

    2014-01-01

    This paper reviews critical water hammer parameters as they are presented in official hydropower standards and guidelines. A particular emphasize is given to a number of IEC standards and guidelines that are used worldwide. The paper critically assesses water hammer control strategies including operational scenarios (closing and opening laws), surge control devices (surge tank, pressure regulating valve, flywheel, etc.), redesign of the water conveyance system components (tunnel, penstock), or limitation of operating conditions (limited operating range) that are variably covered in standards and guidelines. Little information is given on industrial water hammer models and solutions elsewhere. These are briefly introduced and discussed in the light of capability (simple versus complex systems), availability of expertise (in house and/or commercial) and uncertainty. The paper concludes with an interesting water hammer case study referencing the rules and recommendations from existing hydropower standards and guidelines in a view of effective water hammer control. Recommendations are given for further work on development of a special guideline on water hammer (hydraulic transients) in hydropower plants

  19. Treatise on water hammer in hydropower standards and guidelines

    Science.gov (United States)

    Bergant, A.; Karney, B.; Pejović, S.; Mazij, J.

    2014-03-01

    This paper reviews critical water hammer parameters as they are presented in official hydropower standards and guidelines. A particular emphasize is given to a number of IEC standards and guidelines that are used worldwide. The paper critically assesses water hammer control strategies including operational scenarios (closing and opening laws), surge control devices (surge tank, pressure regulating valve, flywheel, etc.), redesign of the water conveyance system components (tunnel, penstock), or limitation of operating conditions (limited operating range) that are variably covered in standards and guidelines. Little information is given on industrial water hammer models and solutions elsewhere. These are briefly introduced and discussed in the light of capability (simple versus complex systems), availability of expertise (in house and/or commercial) and uncertainty. The paper concludes with an interesting water hammer case study referencing the rules and recommendations from existing hydropower standards and guidelines in a view of effective water hammer control. Recommendations are given for further work on development of a special guideline on water hammer (hydraulic transients) in hydropower plants.

  20. Design principle of TVO's final repository and preliminary adaptation to site specific conditions

    International Nuclear Information System (INIS)

    Salo, J-P.; Reikkola, R.

    1995-01-01

    Teollisuuden Voima Oy (TVO) is responsible for the management of spent fuel produced by the Olkiluoto power plant. TVO's current programme of spent fuel management is based on the guidelines and time schedule set by the Finnish Government. TVO has studied a final disposal concept in which the spent fuel bundles are encapsulated in copper canisters and emplaced in Finnish bedrock. According to the plan the final repository for spent fuel will be in operation by 2020. TVO's updated technical plans for the disposal of spent fuel together with a performance analysis (TVO-92) were submitted to the authorities in 1992. The paper describes the design principle of TVO's final repository and preliminary adaptation of the repository to site specific conditions. (author). 10 refs., 5 figs

  1. Adaptive strategies of remote systems operators exposed to perturbed camera-viewing conditions

    Science.gov (United States)

    Stuart, Mark A.; Manahan, Meera K.; Bierschwale, John M.; Sampaio, Carlos E.; Legendre, A. J.

    1991-01-01

    This report describes a preliminary investigation of the use of perturbed visual feedback during the performance of simulated space-based remote manipulation tasks. The primary objective of this NASA evaluation was to determine to what extent operators exhibit adaptive strategies which allow them to perform these specific types of remote manipulation tasks more efficiently while exposed to perturbed visual feedback. A secondary objective of this evaluation was to establish a set of preliminary guidelines for enhancing remote manipulation performance and reducing the adverse effects. These objectives were accomplished by studying the remote manipulator performance of test subjects exposed to various perturbed camera-viewing conditions while performing a simulated space-based remote manipulation task. Statistical analysis of performance and subjective data revealed that remote manipulation performance was adversely affected by the use of perturbed visual feedback and performance tended to improve with successive trials in most perturbed viewing conditions.

  2. The European Stroke Organisation Guidelines : a standard operating procedure

    NARCIS (Netherlands)

    Ntaios, George; Bornstein, Natan M.; Caso, Valeria; Christensen, Hanne; De Keyser, Jacques; Diener, Hans-Christoph; Diez-Tejedor, Exuperio; Ferro, Jose M.; Ford, Gary A.; Grau, Armin; Keller, Emanuella; Leys, Didier; Russell, David; Toni, Danilo; Turc, Guillaume; Van der Worp, Bart; Wahlgren, Nils; Steiner, Thorsten

    2015-01-01

    In 2008, the recently founded European Stroke Organisation published its guidelines for the management of ischemic stroke and transient ischemic attack. This highly cited document was translated in several languages and was updated in 2009. Since then, the European Stroke Organisation has published

  3. Index-TB guidelines: Guidelines on extrapulmonary tuberculosis for India

    Directory of Open Access Journals (Sweden)

    Surendra K Sharma

    2017-01-01

    Full Text Available Extrapulmonary tuberculosis (EPTB is frequently a diagnostic and therapeutic challenge. It is a common opportunistic infection in people living with HIV/AIDS and other immunocompromised states such as diabetes mellitus and malnutrition. There is a paucity of data from clinical trials in EPTB and most of the information regarding diagnosis and management is extrapolated from pulmonary TB. Further, there are no formal national or international guidelines on EPTB. To address these concerns, Indian EPTB guidelines were developed under the auspices of Central TB Division and Directorate of Health Services, Ministry of Health and Family Welfare, Government of India. The objective was to provide guidance on uniform, evidence-informed practices for suspecting, diagnosing and managing EPTB at all levels of healthcare delivery. The guidelines describe agreed principles relevant to 10 key areas of EPTB which are complementary to the existing country standards of TB care and technical operational guidelines for pulmonary TB. These guidelines provide recommendations on three priority areas for EPTB: (i use of Xpert MTB/RIF in diagnosis, (ii use of adjunct corticosteroids in treatment, and (iii duration of treatment. The guidelines were developed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE criteria, which were evidence based, and due consideration was given to various healthcare settings across India. Further, for those forms of EPTB in which evidence regarding best practice was lacking, clinical practice points were developed by consensus on accumulated knowledge and experience of specialists who participated in the working groups. This would also reflect the needs of healthcare providers and develop a platform for future research.

  4. Preliminary hazards analysis -- vitrification process

    International Nuclear Information System (INIS)

    Coordes, D.; Ruggieri, M.; Russell, J.; TenBrook, W.; Yimbo, P.

    1994-06-01

    This paper presents a Preliminary Hazards Analysis (PHA) for mixed waste vitrification by joule heating. The purpose of performing a PHA is to establish an initial hazard categorization for a DOE nuclear facility and to identify those processes and structures which may have an impact on or be important to safety. The PHA is typically performed during and provides input to project conceptual design. The PHA is then followed by a Preliminary Safety Analysis Report (PSAR) performed during Title 1 and 2 design. The PSAR then leads to performance of the Final Safety Analysis Report performed during the facility's construction and testing. It should be completed before routine operation of the facility commences. This PHA addresses the first four chapters of the safety analysis process, in accordance with the requirements of DOE Safety Guidelines in SG 830.110. The hazards associated with vitrification processes are evaluated using standard safety analysis methods which include: identification of credible potential hazardous energy sources; identification of preventative features of the facility or system; identification of mitigative features; and analyses of credible hazards. Maximal facility inventories of radioactive and hazardous materials are postulated to evaluate worst case accident consequences. These inventories were based on DOE-STD-1027-92 guidance and the surrogate waste streams defined by Mayberry, et al. Radiological assessments indicate that a facility, depending on the radioactive material inventory, may be an exempt, Category 3, or Category 2 facility. The calculated impacts would result in no significant impact to offsite personnel or the environment. Hazardous materials assessment indicates that a Mixed Waste Vitrification facility will be a Low Hazard facility having minimal impacts to offsite personnel and the environment

  5. Preliminary hazards analysis -- vitrification process

    Energy Technology Data Exchange (ETDEWEB)

    Coordes, D.; Ruggieri, M.; Russell, J.; TenBrook, W.; Yimbo, P. [Science Applications International Corp., Pleasanton, CA (United States)

    1994-06-01

    This paper presents a Preliminary Hazards Analysis (PHA) for mixed waste vitrification by joule heating. The purpose of performing a PHA is to establish an initial hazard categorization for a DOE nuclear facility and to identify those processes and structures which may have an impact on or be important to safety. The PHA is typically performed during and provides input to project conceptual design. The PHA is then followed by a Preliminary Safety Analysis Report (PSAR) performed during Title 1 and 2 design. The PSAR then leads to performance of the Final Safety Analysis Report performed during the facility`s construction and testing. It should be completed before routine operation of the facility commences. This PHA addresses the first four chapters of the safety analysis process, in accordance with the requirements of DOE Safety Guidelines in SG 830.110. The hazards associated with vitrification processes are evaluated using standard safety analysis methods which include: identification of credible potential hazardous energy sources; identification of preventative features of the facility or system; identification of mitigative features; and analyses of credible hazards. Maximal facility inventories of radioactive and hazardous materials are postulated to evaluate worst case accident consequences. These inventories were based on DOE-STD-1027-92 guidance and the surrogate waste streams defined by Mayberry, et al. Radiological assessments indicate that a facility, depending on the radioactive material inventory, may be an exempt, Category 3, or Category 2 facility. The calculated impacts would result in no significant impact to offsite personnel or the environment. Hazardous materials assessment indicates that a Mixed Waste Vitrification facility will be a Low Hazard facility having minimal impacts to offsite personnel and the environment.

  6. Advanced human-system interface design review guideline. General evaluation model, technical development, and guideline description

    International Nuclear Information System (INIS)

    O'Hara, J.M.

    1994-07-01

    Advanced control rooms will use advanced human-system interface (HSI) technologies that may have significant implications for plant safety in that they will affect the operator's overall role in the system, the method of information presentation, and the ways in which operators interact with the system. The U.S. Nuclear Regulatory Commission (NRC) reviews the HSI aspects of control rooms to ensure that they are designed to good human factors engineering principles and that operator performance and reliability are appropriately supported to protect public health and safety. The principal guidance available to the NRC, however, was developed more than ten years ago, well before these technological changes. Accordingly, the human factors guidance needs to be updated to serve as the basis for NRC review of these advanced designs. The purpose of this project was to develop a general approach to advanced HSI review and the human factors guidelines to support NRC safety reviews of advanced systems. This two-volume report provides the results of the project. Volume I describes the development of the Advanced HSI Design Review Guideline (DRG) including (1) its theoretical and technical foundation, (2) a general model for the review of advanced HSIs, (3) guideline development in both hard-copy and computer-based versions, and (4) the tests and evaluations performed to develop and validate the DRG. Volume I also includes a discussion of the gaps in available guidance and a methodology for addressing them. Volume 2 provides the guidelines to be used for advanced HSI review and the procedures for their use

  7. Joint IAEA/NEA IRS guidelines

    International Nuclear Information System (INIS)

    1997-01-01

    The Incident Reporting System (IRS) is an international system jointly operated by the International Atomic Energy Agency (IAEA) and the Nuclear Energy Agency of the Organization for Economic Cooperation and Development (OECD/NEA). The fundamental objective of the IRS is to contribute to improving the safety of commercial nuclear power plants (NPPs) which are operated worldwide. This objective can be achieved by providing timely and detailed information on both technical and human factors related to events of safety significance which occur at these plants. The purpose of these guidelines, which supersede the previous IAEA Safety Series No. 93 (Part II) and the NEA IRS guidelines, is to describe the system and to give users the necessary background and guidance to enable them to produce IRS reports meeting a high standard of quality while retaining the high efficiency of the system expected by all Member States operating nuclear power plants

  8. The European Standards and Guidelines and the Evaluation of Agencies in Germany

    Science.gov (United States)

    Hopbach, Achim

    2006-01-01

    This paper presents preliminary findings from the application of the European Standards and Guidelines (ESG) to the Accreditation Council's accreditation criteria and the review of three German accreditation agencies done by the German Accreditation Council. It focuses on the main characteristics of the ESG and their implementation into the German…

  9. Guidelines for Self-assessment of Research Reactor Safety

    International Nuclear Information System (INIS)

    2018-01-01

    Self-assessment is an organization’s internal process to review its current status, processes and performance against predefined criteria and thereby to provide key elements for the organization’s continual development and improvement. Self-assessment helps the organization to think through what it is expected to do, how it is performing in relation to these expectations, and what it needs to do to improve performance, fulfil the expectations and achieve better compliance with the predefined criteria. This publication provides guidelines for a research reactor operating organization to perform a self-assessment of the safety management and the safety of the facility and to identify gaps between the current situation and the IAEA safety requirements for research reactors. These guidelines also provide a methodology for Member States, regulatory bodies and operating organizations to perform a self-assessment of their application of the provisions of the Code of Conduct on the Safety of Research Reactors. This publication also addresses planning, implementation and follow-up of actions to enhance safety and strengthen application of the Code. The guidelines are applicable to all types of research reactor and critical and subcritical assemblies, at all stages in their lifetimes, and to States, regulatory bodies and operating organizations throughout all phases of research reactor programmes. Research reactor operating organizations can use these guidelines at any time to support self-assessments conducted in accordance with the organization’s integrated management system. These guidelines also serve as a tool for an organization to prepare to receive an IAEA Integrated Safety Assessment of Research Reactors (INSARR) mission. An important result of this is the opportunity for an operating organization to identify focus areas and make safety improvements in advance of an INSARR mission, thereby increasing the effectiveness of the mission and efficiency of the

  10. Feature-Fusion Guidelines for Image-Based Multi-Modal Biometric Fusion

    Directory of Open Access Journals (Sweden)

    Dane Brown

    2017-07-01

    Full Text Available The feature level, unlike the match score level, lacks multi-modal fusion guidelines. This work demonstrates a new approach for improved image-based biometric feature-fusion. The approach extracts and combines the face, fingerprint and palmprint at the feature level for improved human identification accuracy. Feature-fusion guidelines, proposed in our recent work, are extended by adding a new face segmentation method and the support vector machine classifier. The new face segmentation method improves the face identification equal error rate (EER by 10%. The support vector machine classifier combined with the new feature selection approach, proposed in our recent work, outperforms other classifiers when using a single training sample. Feature-fusion guidelines take the form of strengths and weaknesses as observed in the applied feature processing modules during preliminary experiments. The guidelines are used to implement an effective biometric fusion system at the feature level, using a novel feature-fusion methodology, reducing the EER of two groups of three datasets namely: SDUMLA face, SDUMLA fingerprint and IITD palmprint; MUCT Face, MCYT Fingerprint and CASIA Palmprint.

  11. Guidelines for evaluation of the environmental expense

    International Nuclear Information System (INIS)

    Komatsu, Cintia Nagako; Aquino, Afonso Rodrigues de

    2009-01-01

    The main objective of this research is to establish guidelines to fit the Environment Account in the Nuclear Fuel Cycle, using as study of case the Uranium Hexafluoride Production Unit of Centro Tecnologico da Marinha in Sao Paulo. The environment accounting, branch of the accounting science, supply a source of tools capable to measure the protection efforts, the nature preservation, the environment monitoring and the recovering during all the Conversion phase (since the Uranium concentrated, the yellow cake, up to the Uranium hexafluoride production). It was performed several researches, visits to the Centre, databank creation, interviews and extensive consulting to the preliminary safety report, in order to obtain the percentage of the total expenses related to environment protection in regarding to the total amount invested in the unit. It was also evaluated the total preserved green area making possible a preliminary environment accounting balance. (author)

  12. Guidelines for preparing IAEA design information questionnaires

    International Nuclear Information System (INIS)

    Swartz, J.M.; Bieber, A.M.

    1980-01-01

    The format of the IAEA Design Information Questionnaires and the SAI prepared guidelines for completing them, is described. The guidelines should assist facility operators in meeting the time constraints set forth in the Subsidiary Arrangements by effectively supplying the information needed by the IAEA and in minimizing resource allocations to the preparation effort. 8 refs

  13. Advanced human-system interface design review guideline. Evaluation procedures and guidelines for human factors engineering reviews

    International Nuclear Information System (INIS)

    O'Hara, J.M.; Brown, W.S.; Baker, C.C.; Welch, D.L.; Granda, T.M.; Vingelis, P.J.

    1994-07-01

    Advanced control rooms will use advanced human-system interface (HSI) technologies that may have significant implications for plant safety in that they will affect the operator's overall role in the system, the method of information presentation, and the ways in which operators interact with the system. The U.S. Nuclear Regulatory Commission (NRC) reviews the HSI aspects of control rooms to ensure that they are designed to good human factors engineering principles and that operator performance and reliability are appropriately supported to protect public health and safety. The principal guidance available to the NRC, however, was developed more than ten years ago, well before these technological changes. Accordingly, the human factors guidance needs to be updated to serve as the basis for NRC review of these advanced designs. The purpose of this project was to develop a general approach to advanced HSI review and the human factors guidelines to support. NRC safety reviews of advanced systems. This two-volume report provides the results of the project. Volume I describes the development of the Advanced HSI Design Review Guideline (DRG) including (1) its theoretical and technical foundation, (2) a general model for the review of advanced HSIs, (3) guideline development in both hard-copy and computer-based versions, and (4) the tests and evaluations performed to develop and validate the DRG. Volume I also includes a discussion of the gaps in available guidance and a methodology for addressing them. Volume 2 provides the guidelines to be used for advanced HSI review and the procedures for their use

  14. An International Approach to Enhancing a National Guideline on Driving and Dementia.

    Science.gov (United States)

    Rapoport, Mark J; Chee, Justin N; Carr, David B; Molnar, Frank; Naglie, Gary; Dow, Jamie; Marottoli, Richard; Mitchell, Sara; Tant, Mark; Herrmann, Nathan; Lanctôt, Krista L; Taylor, John-Paul; Donaghy, Paul C; Classen, Sherrilene; O'Neill, Desmond

    2018-03-12

    The purpose of this study was to update a national guideline on assessing drivers with dementia, addressing limitations of previous versions which included a lack of developmental rigor and stakeholder involvement. An international multidisciplinary team reviewed 104 different recommendations from 12 previous guidelines on assessing drivers with dementia in light of a recent review of the literature. Revised guideline recommendations were drafted by consensus. A preliminary draft was sent to specialist physician and occupational therapy groups for feedback, using an a priori definition of 90% agreement as consensus. The research team drafted 23 guideline recommendations, and responses were received from 145 stakeholders. No recommendation was endorsed by less than 80% of respondents, and 14 (61%) of the recommendations were endorsed by more than 90%.The recommendations are presented in the manuscript. The revised guideline incorporates the perspectives of consensus of an expert group as well as front-line clinicians who regularly assess drivers with dementia. The majority of the recommendations were based on evidence at the level of expert opinion, revealing gaps in the evidence and future directions for research.

  15. Efforts to update firefighter safety zone guidelines

    Science.gov (United States)

    Bret Butler

    2009-01-01

    One of the most critical decisions made on wildland fires is the identification of suitable safety zones for firefighters during daily fire management operations. To be effective (timely, repeatable, and accurate), these decisions rely on good training and judgment, but also on clear, concise guidelines. This article is a summary of safety zone guidelines and the...

  16. Air quality guidelines for arenas in Nova Scotia

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-05-01

    A series of guidelines have been prepared to address the quality of air in skating arena facilities in Nova Scotia. They are limited to carbon monoxide and nitrogen dioxide emissions. Average nitrogen dioxide levels should not exceed 1 part per million (ppm). Average carbon monoxide levels should not exceed 25 ppm. These guidelines do not address other contaminants such as ammonia or chlorofluorocarbons (CFCs). The guidelines are considered to be the minimum standards required for safe arena operations. These standards can be met by reducing emissions of the ice resurfacer and edger which is one of the major sources of poor air quality in arenas. Other ways to meet the standards are to ensure proper equipment operation, ventilation and monitoring of indoor air quality levels. Symptoms of exposure and potential consequences were also described. It was noted that owners and operators may be found libel for injury if a proper environment is not maintained. 6 appendices.

  17. Operating performance and environmental and safety risks: A preliminary comparison of majors and independents

    International Nuclear Information System (INIS)

    Pulsipher, A.G.; Iledare, W.O.; Baumann, R.H.; Mesyanzhinov, D.

    1995-01-01

    The objective is to compare the safety and environmental records of oil and gas companies operating on the OCS in the Gulf of Mexico over the past decade. The reason for doing so is to help inform public sector policy-makers and private sector decision-makers about the potential safety and environmental risks associated with the expected increased presence of smaller independents in the domestic oil and gas industry in general and on the federal OCS in particular. The preliminary conclusion is that although independents have had a modestly high incidence of fires and explosions than the majors, the difference is not significant statistically and is largely attributable to a few ''bad actors'' rather than demonstrably poorer practice by the group as a whole

  18. Preliminary design report for the prototypical fuel rod consolidation system

    International Nuclear Information System (INIS)

    Rosa, J.M.

    1986-01-01

    This report documents NUTECH's preliminary design of a dry, spent fuel rod consolidation system. This preliminary design is the result of Phase I of a planned four phase project. The present report on this project provides a considerable amount of detail for a preliminary design effort. The design and all of its details are described in this Preliminary Design Report (PDR). The NUTECH dry rod consolidation system described herein is remotely operated. It provides for automatic operation, but with operator hold points between key steps in the process. The operator has the ability to switch to a manual operation mode at any point in the process. The system is directed by the operator using an executive computer which controls and coordinates the operation of the in-cell equipment. The operator monitors the process using an in-cell closed circuit television (CCTV) system with audio output and equipment status displays on the computer monitor. The in-cell mechanical equipment consists of the following: (1) two overhead cranes with manipulators; (2) a multi-degree of freedom fuel handling table and its clamping equipment; (3) a fuel assembly end fitting removal station and its tools; (4) a consolidator (which pulls rods, assembles the consolidated bundle and loads the canister); (5) a canister end cap welder and weld inspection system; (6) decontamination systems; and (7) the CCTV and microphone systems

  19. Environmental Design Guidelines for Low Crested Coastal Structures

    DEFF Research Database (Denmark)

    Burcharth, Hans F.; Hawkins, Stephen J.; Zanuttigh, Barbara

    selected to represent a variety of environmental conditions (Chapter 11); the application of the proposed methodology to a real prototype case, in order to give a practical example to designers (Chapter 12). The third part contains all the formulae and tools to help engineers (Chapter 13), ecologists....... The guidelines have been drafted in a generic way to be appropriate throughout the European Union taking into regard current European Commission policy and directives to promote sustainable development and integrated coastal zone management. The guidelines are composed of three main parts. The first part...... (Chapters 1-10) contains the description of the design methodology, from the preliminary identification of design alternatives till the selection of the sustainable scheme and its construction. The second part presents: the analysis of the performance of beach defences in DELOS study sites, which were...

  20. Preliminary assessment of risk of ozone impacts to maize (Zea mays) in Southern Africa

    CSIR Research Space (South Africa)

    Van Tienhoven, AM

    2006-03-01

    Full Text Available Surface ozone concentrations in southern Africa exceed air quality guidelines set to protect agricultural crops. This paper addresses a knowledge gap by performing a preliminary assessment of potential ozone impacts on vegetation in southern African...

  1. EPRI PWR primary water chemistry guidelines revision

    International Nuclear Information System (INIS)

    McElrath, Joel; Fruzzetti, Keith

    2014-01-01

    EPRI periodically updates the PWR Primary Water Chemistry Guidelines as new information becomes available and as required by NEI 97-06 (Steam Generator Program Guidelines) and NEI 03-08 (Guideline for the Management of Materials Issues). The last revision of the PWR water chemistry guidelines identified an optimum primary water chemistry program based on then-current understanding of research and field information. This new revision provides further details with regard to primary water stress corrosion cracking (PWSCC), fuel integrity, and shutdown dose rates. A committee of industry experts, including utility specialists, nuclear steam supply system (NSSS) and fuel vendor representatives, Institute of Nuclear Power Operations (INPO) representatives, consultants, and EPRI staff collaborated in reviewing the available data on primary water chemistry, reactor water coolant system materials issues, fuel integrity and performance issues, and radiation dose rate issues. From the data, the committee updated the water chemistry guidelines that all PWR nuclear plants should adopt. The committee revised guidance with regard to optimization to reflect industry experience gained since the publication of Revision 6. Among the changes, the technical information regarding the impact of zinc injection on PWSCC initiation and dose rate reduction has been updated to reflect the current level of knowledge within the industry. Similarly, industry experience with elevated lithium concentrations with regard to fuel performance and radiation dose rates has been updated to reflect data collected to date. Recognizing that each nuclear plant owner has a unique set of design, operating, and corporate concerns, the guidelines committee has retained a method for plant-specific optimization. Revision 7 of the Pressurized Water Reactor Primary Water Chemistry Guidelines provides guidance for PWR primary systems of all manufacture and design. The guidelines continue to emphasize plant

  2. European guidelines for workplace drug testing in urine.

    Science.gov (United States)

    Taskinen, Sanna; Beck, Olof; Bosch, Tessa; Brcak, Michaela; Carmichael, Duncan; Fucci, Nadia; George, Claire; Piper, Mark; Salomone, Alberto; Schielen, Wim; Steinmeyer, Stefan; Weinmann, Wolfgang

    2017-06-01

    These European Guidelines for Workplace Drug Testing in Urine have been prepared and updated by the European Workplace Drug Testing Society (EWDTS). The first version of these urine guidelines was published in 2002. Since then, the guidelines have been followed by many laboratories in different European countries and their role has been essential particularly in countries lacking legislation for workplace drug testing. In 2014, the EWDTS started a guidelines updating project and published a new version of the urine guidelines in 2015. Here we represent this updated version of the urine guidelines. The European Guidelines are designed to establish best practice procedures whilst allowing individual countries to operate within the requirements of national customs and legislation. The EWDTS recommends that all European laboratories that undertake legally defensible workplace drug testing should use these guidelines as a template for accreditation. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  3. Results of the preliminary radiological survey at the former Diamond Magnesium Company site, Luckey, Ohio (DML001)

    International Nuclear Information System (INIS)

    Foley, R.D.; Crutcher, J.W.

    1990-02-01

    As part of the Formerly Utilized Sites Remedial Action Program, the US Department of Energy (DOE) is implementing a radiological survey program to determine the radiological conditions at sites that were used by the department's predecessor agencies. One such site is the former Diamond Magnesium Company facility in Luckey, Ohio. The preliminary radiological survey discussed in this report was conducted at the request of DOE by members of the Measurement Applications and Development group of Oak Ridge National Laboratory in December 1988. The former Diamond Magnesium Company site in Luckey, Ohio, was used as a magnesium reduction plant during World War 2. It was closed in 1945 and reopened in 1949 as a beryllium production facility, operated by Brush Wellman for the US Atomic Energy Commission. The preliminary radiological survey included: a surface gamma scan of part of the property outdoors, collection of surface and subsurface soil samples, and collection of water samples. Laboratory analysis of soil samples showed concentrations of 226 Ra in excess of applicable DOE guidelines. A follow-up, detailed survey is recommended. 9 refs., 10 figs., 4 tabs

  4. Effects prediction guidelines for structures subjected to ground motion

    International Nuclear Information System (INIS)

    1975-07-01

    Part of the planning for an underground nuclear explosion (UNE) is determining the effects of expected ground motion on exposed structures. Because of the many types of structures and the wide variation in ground motion intensity typically encountered, no single prediction method is both adequate and feasible for a complete evaluation. Furthermore, the nature and variability of ground motion and structure damage prescribe effects predictions that are made probabilistically. Initially, prediction for a UNE involves a preliminary assessment of damage to establish overall project feasibility. Subsequent efforts require more detailed damage evaluations, based on structure inventories and analyses of specific structures, so that safety problems can be identified and safety and remedial measures can be recommended. To cover this broad range of effects prediction needs for a typical UNE project, three distinct but interrelated methods have been developed and are described. First, the fundamental practical and theoretical aspects of predicting the effects of dynamic ground motion on structures are summarized. Next, experimentally derived and theoretically determined observations of the behavior of typical structures subjected to ground motion are presented. Then, based on these fundamental considerations and on the observed behavior of structures, the formulation of the three effects prediction procedures is described, along with guidelines regarding their applicability. Example damage predictions for hypothetical UNEs demonstrate these procedures. To aid in identifying the vibration properties of complex structures, one chapter discusses alternatives in vibration testing, instrumentation, and data analysis. Finally, operational guidelines regarding data acquisition procedures, safety criteria, and remedial measures involved in conducting structure effects evaluations are discussed. (U.S.)

  5. Additional guideline for the design of BWR reload patterns

    International Nuclear Information System (INIS)

    Burte, D.P.

    1990-01-01

    The problems of the high magnitude of the reactivity worths of control rods/notches and the thermal shocks to fuel due to control rod withdrawals are considered in this paper. These problems are shown to be mitigated if in addition to complying with the traditional guidelines for designing fuel bundles and reload patterns the proposed additional guideline (in the form of the condition that the shape of the K∞ distribution remains constant throughout the cycle) is also complied with. It is argued that application of the additional guideline for operating conditions ensures that the core can operate with a constant power profile throughout the cycle without control rod movement. Fixed (integral or stand-alone) burnable poisons are thought to be useful in this regard. Some comments on how this may be attempted are included. Additional advantages resulting from the additional guideline are discussed. (author)

  6. Derivation of residual radioactive material guidelines for 13 radionuclides present in Operable Unit IV at Brookhaven National Laboratory, Upton, New York

    International Nuclear Information System (INIS)

    Faillace, E.; Nimmagadda, M.; Yu, C.

    1994-12-01

    Residual radioactive material guidelines for 13 radionuclides (americium-241; cobalt-60; cesium-137; europium-152, -154, and -155; plutonium-238, -239, and -240; strontium-90; and uranium-234, -235, and -238) were derived for Operable Unit (OU) IV at Brookhaven National Laboratory. This site has been identified for remedial action under the Comprehensive Environmental Response, Compensation, and Liability Act of 1980, as amended by the Superfund Amendments and Reauthorization Act of 1986. Single-nuclide guidelines were derived on the basis of the requirement that the 50-year committed effective dose equivalent to a hypothetical individual who lives or works in the immediate vicinity of OU IV should not exceed a dose constraint of 30 mrem/yr following remedial action for the current use and plausible future use scenarios or a dose limit of 100 mrem/yr for plausible but less likely future use scenarios. The US Department of Energy (DOE) residual radioactive material guideline computer code, RESRAD, was used in this evaluation; RESRAD implements the methodology described in the DOE manual for determining residual radioactive material guidelines. Four potential scenarios were considered; each assumed that, for a period of 1,000 years following remedial action, the site would be used without radiological restrictions. The four scenarios varied with regard to the type of site use, time spent at the site, and sources of food consumed

  7. Guidelines for nuclear reactor equipments safety-analysis

    International Nuclear Information System (INIS)

    1978-01-01

    The safety analysis in approving the applications for nuclear reactor constructions (or alterations) is performed by the Committee on Examination of Reactor Safety in accordance with various guidelines prescribed by the Atomic Energy Commission. In addition, the above Committee set forth its own regulations for the safety analysis on common problems among various types of nuclear reactors. This book has collected and edited those guidelines and regulations. It has two parts: Part I includes the guidelines issued to date by the Atomic Energy Commission: and Part II - regulations of the Committee. Part I has collected 8 categories of guidelines which relate to following matters: nuclear reactor sites analysis guidelines and standards for their applications; standard exposure dose of plutonium; nuclear ship operation guidelines; safety design analysis guidelines for light-water type, electricity generating nuclear reactor equipments; safety evaluation guidelines for emergency reactor core cooling system of light-water type power reactors; guidelines for exposure dose target values around light-water type electricity generating nuclear reactor equipments, and guidelines for evaluation of above target values; and meteorological guidelines for the safety analysis of electricity generating nuclear reactor equipments. Part II includes regulations of the Committee concerning - the fuel assembly used in boiling-water type and in pressurized-water type reactors; techniques of reactor core heat designs, etc. in boiling-water reactors; and others

  8. Preliminary results of Resistive Plate Chambers operated with eco-friendly gas mixtures for application in the CMS experiment

    CERN Document Server

    Abbrescia, Marcello; Benussi, Luigi; Bianco, Stefano; Cauwenbergh, Simon Marc D; Ferrini, Mauro; Muhammad, Saleh; Passamontic, L; Pierluigi, Daniele; Piccolo, Davide; Primavera, Federica; Russo, Alessandro; Savianoc, G; Tytgat, Michael

    2016-01-01

    The operations of Resistive Plate Chambers in LHC experiments require F-based gases for optimal performance. Recent regulations demand the use of environmentally unfriendly F-based gases to be limited or banned. In view of the CMS experiment upgrade several tests are ongoing to measure the performance of the detector in terms of efficiency, streamer probability, induced charge and time resolution. Prototype chambers with readout pads and with the standard cms electronic setup are under test. In this talk preliminary results on performance of RPCs operated with a potential eco-friendly gas candidate 1,3,3,3-Tetrafluoropropene, commercially known as HFO-1234ze and with CO2 based gas mixtures are presented and discussed for the possible application in the CMS experiment.

  9. Functional Hypothalamic Amenorrhea: An Endocrine Society Clinical Practice Guideline.

    Science.gov (United States)

    Gordon, Catherine M; Ackerman, Kathryn E; Berga, Sarah L; Kaplan, Jay R; Mastorakos, George; Misra, Madhusmita; Murad, M Hassan; Santoro, Nanette F; Warren, Michelle P

    2017-05-01

    The American Society for Reproductive Medicine, the European Society of Endocrinology, and the Pediatric Endocrine Society. This guideline was funded by the Endocrine Society. To formulate clinical practice guidelines for the diagnosis and treatment of functional hypothalamic amenorrhea (FHA). The participants include an Endocrine Society-appointed task force of eight experts, a methodologist, and a medical writer. This evidence-based guideline was developed using the Grading of Recommendations, Assessment, Development, and Evaluation approach to describe the strength of recommendations and the quality of evidence. The task force commissioned two systematic reviews and used the best available evidence from other published systematic reviews and individual studies. One group meeting, several conference calls, and e-mail communications enabled consensus. Endocrine Society committees and members and cosponsoring organizations reviewed and commented on preliminary drafts of this guideline. FHA is a form of chronic anovulation, not due to identifiable organic causes, but often associated with stress, weight loss, excessive exercise, or a combination thereof. Investigations should include assessment of systemic and endocrinologic etiologies, as FHA is a diagnosis of exclusion. A multidisciplinary treatment approach is necessary, including medical, dietary, and mental health support. Medical complications include, among others, bone loss and infertility, and appropriate therapies are under debate and investigation. Copyright © 2017 Endocrine Society

  10. Space station pressurized laboratory safety guidelines

    Science.gov (United States)

    Mcgonigal, Les

    1990-01-01

    Before technical safety guidelines and requirements are established, a common understanding of their origin and importance must be shared between Space Station Program Management, the User Community, and the Safety organizations involved. Safety guidelines and requirements are driven by the nature of the experiments, and the degree of crew interaction. Hazard identification; development of technical safety requirements; operating procedures and constraints; provision of training and education; conduct of reviews and evaluations; and emergency preplanning are briefly discussed.

  11. Hormonal Replacement in Hypopituitarism in Adults: An Endocrine Society Clinical Practice Guideline.

    Science.gov (United States)

    Fleseriu, Maria; Hashim, Ibrahim A; Karavitaki, Niki; Melmed, Shlomo; Murad, M Hassan; Salvatori, Roberto; Samuels, Mary H

    2016-11-01

    To formulate clinical practice guidelines for hormonal replacement in hypopituitarism in adults. The participants include an Endocrine Society-appointed Task Force of six experts, a methodologist, and a medical writer. The American Association for Clinical Chemistry, the Pituitary Society, and the European Society of Endocrinology co-sponsored this guideline. The Task Force developed this evidence-based guideline using the Grading of Recommendations, Assessment, Development, and Evaluation system to describe the strength of recommendations and the quality of evidence. The Task Force commissioned two systematic reviews and used the best available evidence from other published systematic reviews and individual studies. One group meeting, several conference calls, and e-mail communications enabled consensus. Committees and members of the Endocrine Society, the American Association for Clinical Chemistry, the Pituitary Society, and the European Society of Endocrinology reviewed and commented on preliminary drafts of these guidelines. Using an evidence-based approach, this guideline addresses important clinical issues regarding the evaluation and management of hypopituitarism in adults, including appropriate biochemical assessments, specific therapeutic decisions to decrease the risk of co-morbidities due to hormonal over-replacement or under-replacement, and managing hypopituitarism during pregnancy, pituitary surgery, and other types of surgeries.

  12. Procurement guideline for oil recovery boats; Oeljyntorjuntaveneen hankintaohje

    Energy Technology Data Exchange (ETDEWEB)

    Pajala, J.

    2011-12-15

    These guidelines have been compiled to assist in the procurement of oil recovery boats, with the intention of ensuring that new boats meet the future needs of oil spill response operations and that procurement will be carried out in a manner that is economically sound and technologically well-founded. Furthermore, the guidelines are intended to encourage the development and adoption of new solutions for oil recovery boats. The issues covered by these guidelines include: Multiple uses of boats, classification of boats and class-specific requirements, the principle of sustainable development and the boats' lifecycle, qualification to be set for the crews, procurement timeline, regulations and guidelines, inspections and approvals. (orig.)

  13. A study on design guidelines for the icons used in nuclear power plants

    International Nuclear Information System (INIS)

    Lee, Jung Woon; Lee, Yong Hee; Oh, In Seok; Lee, Hyun Chul; Lee, Dhong Ha

    2004-05-01

    In this project, advantages and disadvantages of icons on electronic displays were analyzed, and design procedures, design evaluation principles, and design guidelines for icons on electronic displays were developed. In addition, as design guidelines for special effects applicable to icons on electronic displays, guidelines for color coding, flashing, and 3-dimensional effects were developed. A questionnaire survey was performed to investigate how NPP operators consider methods representing icons on electronic displays (such as colors, dynamic effects, and 3-dimensional effects) compared to methods representing icons by using outlines in the P and ID drawings. NPP operators' preference of the icons designed in accordance with icon design guidelines to the icons without considering the guidelines was also investigated

  14. Guidelines for multipurpose data systems for nuclear power plants

    International Nuclear Information System (INIS)

    1994-07-01

    This TECDOC is intended to provide guidance on implementing a system to provide the staff and management of a nuclear power plant with data and information specific to the plant, to assist in making decisions concerning plant operation and maintenance. The guidelines do not deal with issues relating to software and hardware for database management owing to the rapid evolution in these technologies. It will be up to individual utilities to select a suitable technology to meet their data system needs. The guidelines are intended to help a utility with operating plants and/or plants under construction to implement a system which best suits its needs for the compilation of plant specific data. The plant specific data will in turn help in generating quantitative and qualitative results and insights to support decision making for optimized plant operation and maintenance. The guidelines are supplemented by examples of the data systems in use at the utilities that contributed to the preparation of the document Figs and tabs

  15. ITER Operating Limits and Conditions

    International Nuclear Information System (INIS)

    Ciattaglia, S.; Barabaschi, P.; Carretero, J.A.

    2006-01-01

    The Operating Limits and Conditions (OLCs) are operating parameters and conditions, chosen among all system/components, which together define the domain of the safe operation of ITER in all foreseen ITER status (operation, maintenance, commissioning). At the same time they are selected to guarantee the required operation flexibility which is a critical factor for the success of an experimental machine such as ITER. System and components important for personnel or public safety (Safety Important Class, SIC) are identified from the overall plant safety analysis on functional importance to safety of the components. SIC classification has to be presented already inside the preliminary safety analysis report and approved by the licensing safety authority before the relevant construction. OLCs comprise the safety limits, i.e. that if exceeded could result in a potential safety hazard, the relevant settings that determine the intervention of SIC systems and the operational limits on equipment which warn from or stop a functional departure from a planned operational status that could challenge equipment and functions. The safety limits have to indicate clearly states that leave the nominal safety state of ITER; they are derived from the safety analysis of ITER. OLCs can represent in some cases few parameters grouping together. Some operational conditions, e.g. inventories, will be controlled through no real time measurements and procedures. Operating experience from present tokamaks, in particular JET, and from nuclear plants is considered at the maximum possible extent. This paper presents the guidelines to develop the ITER OLCs with particular reference to safety limits. A few examples are reported as well as open issues on some OLCs control and measurement and the relevant R-and-D planned to solve the issues. (author)

  16. Pre-operative fasting guidelines: an update

    DEFF Research Database (Denmark)

    Søreide, E; Eriksson, L I; Hirlekar, G

    2005-01-01

    Liberal pre-operative fasting routines have been implemented in most countries. In general, clear fluids are allowed up to 2 h before anaesthesia, and light meals up to 6 h. The same recommendations apply for children and pregnant women not in labour. In children......Liberal pre-operative fasting routines have been implemented in most countries. In general, clear fluids are allowed up to 2 h before anaesthesia, and light meals up to 6 h. The same recommendations apply for children and pregnant women not in labour. In children...

  17. Guidelines for target volume definition in post-operative radiotherapy for prostate cancer, on behalf of the EORTC Radiation Oncology Group

    International Nuclear Information System (INIS)

    Poortmans, Philip; Bossi, Alberto; Vandeputte, Katia; Bosset, Mathieu; Miralbell, Raymond; Maingon, Philippe; Boehmer, Dirk; Budiharto, Tom; Symon, Zvi; Bergh, Alfons C.M. van den; Scrase, Christopher; Poppel, Hendrik van; Bolla, Michel

    2007-01-01

    The appropriate application of 3-D conformal radiotherapy, intensity modulated radiotherapy or image guided radiotherapy for patients undergoing post-operative radiotherapy for prostate cancer requires a standardisation of the target volume definition and delineation as well as standardisation of the clinical quality assurance procedures. Recommendations for this are presented on behalf of the European Organisation for Research and Treatment of Cancer (EORTC) Radiation Oncology Group and in addition to the already published guidelines for radiotherapy as the primary treatment

  18. Preliminary results of Resistive Plate Chambers operated with eco-friendly gas mixtures for application in the CMS experiment

    International Nuclear Information System (INIS)

    Abbrescia, M.; Muhammad, S.; Saviano, G.; Auwegem, P. Van; Cauwenbergh, S.; Tytgat, M.; Benussi, L.; Bianco, S.; Passamonti, L.; Pierluigi, D.; Piccolo, D.; Primavera, F.; Russo, A.; Ferrini, M.

    2016-01-01

    The operations of Resistive Plate Chambers in LHC experiments require Fluorine based (F-based) gases for optimal performance. Recent European regulations demand the use of environmentally unfriendly F-based gases to be limited or banned. In view of the CMS experiment upgrade, several tests are ongoing to measure the performance of the detector with these new ecological gas mixtures, in terms of efficiency, streamer probability, induced charge and time resolution. Prototype chambers with readout pads and with the standard CMS electronic setup are under test. In this paper preliminary results on performance of RPCs operated with a potential eco-friendly gas candidate 1,3,3,3-Tetrafluoropropene, commercially known as HFO-1234ze, with CO 2 and CF 3 I based gas mixtures are presented and discussed for the possible application in the CMS experiment.

  19. Preliminary results of Resistive Plate Chambers operated with eco-friendly gas mixtures for application in the CMS experiment

    CERN Document Server

    Abbrescia, M.

    2016-01-01

    The operations of Resistive Plate Chambers in LHC experiments require Fluorine based (F-based) gases for optimal performance. Recent European regulations demand the use of environmentally unfriendly F-based gases to be limited or banned. In view of the CMS experiment upgrade, several tests are ongoing to measure the performance of the detector with these new ecological gas mixtures, in terms of efficiency, streamer probability, induced charge and time resolution. Prototype chambers with readout pads and with the standard CMS electronic setup are under test. In this paper preliminary results on performance of RPCs operated with a potential eco-friendly gas candidate 1,3,3,3-Tetrafluoropropene, commercially known as HFO-1234ze, with CO2 and CF3I based gas mixtures are presented and discussed for the possible application in the CMS experiment.

  20. Vehicle recovery and towing guideline

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-01-15

    This guideline was developed to provide light and medium duty vehicles operators in the oil and gas industry with a set of best practices for avoiding injury and damage during the recovery of stuck vehicles. The aim of the guideline was to increase awareness of safety issues and promote the safe usage of the vehicles by personnel throughout the petroleum industry and to establish minimum standards of practice for vehicle recovery. The guideline included a step-by-step guide for pulling out a vehicle with a recovery strap as well as vehicle-mounted winch procedures. Pre-job checklists for both procedures were provided. Issues related to the strength rating of vehicle tow hooks and hitch receivers were discussed, as well as some of the hazards associated with steep terrains and heavy mud. The guideline also included recommendations for a vehicle recovery kit with instructions on vehicle recovery, a recovery strap, a recovery hitch and shackle, a collapsible shovel, traffic cones and reflector flares, and a heavy blanket and gloves. 7 refs., 2 tabs., 13 figs.

  1. A Preliminary Evaluation of Supersonic Transport Category Vehicle Operations in the National Airspace System

    Science.gov (United States)

    Underwood, Matthew C.; Guminsky, Michael D.

    2015-01-01

    Several public sector businesses and government agencies, including the National Aeronautics and Space Administration are currently working on solving key technological barriers that must be overcome in order to realize the vision of low-boom supersonic flights conducted over land. However, once these challenges are met, the manner in which this class of aircraft is integrated in the National Airspace System may become a potential constraint due to the significant environmental, efficiency, and economic repercussions that their integration may cause. Background research was performed on historic supersonic operations in the National Airspace System, including both flight deck procedures and air traffic controller procedures. Using this information, an experiment was created to test some of these historic procedures in a current-day, emerging Next Generation Air Transportation System (NextGen) environment and observe the interactions between commercial supersonic transport aircraft and modern-day air traffic. Data was gathered through batch simulations of supersonic commercial transport category aircraft operating in present-day traffic scenarios as a base-lining study to identify the magnitude of the integration problems and begin the exploration of new air traffic management technologies and architectures which will be needed to seamlessly integrate subsonic and supersonic transport aircraft operations. The data gathered include information about encounters between subsonic and supersonic aircraft that may occur when supersonic commercial transport aircraft are integrated into the National Airspace System, as well as flight time data. This initial investigation is being used to inform the creation and refinement of a preliminary Concept of Operations and for the subsequent development of technologies that will enable overland supersonic flight.

  2. Modifications of Probabilistic Safety Assessment-1 Nuclear Power Plant Dukovany based upon new version of Emergency Operating Procedures

    International Nuclear Information System (INIS)

    Aldorf, R.

    1997-01-01

    In the frame of 'living Probabilistic Safety Assessment-1 Nuclear Power Plant Dukovany Project' being performed by Nuclear Research Institute Rez during 1997 is planned to reflect on Probabilistic Safety Assessment-1 basis on impact of Emergency Response Guidelines (as one particular event from the list of other modifications) on Plant Safety. Following highlights help to orient the reader in main general aspects, findings and issues of the work that currently continues on. Older results of Probabilistic Safety Assessment-1 Nuclear Power Plant Dukovany have revealed that human behaviour during accident progression scenarios represent one of the most important aspects in plant safety. Current effort of Nuclear Power Plants Dukovany (Czech Republic) and Bohunice (Slovak Republic) is focussed on development of qualitatively new symptom-based Emergency Operating Procedures called Emergency Response Guidelines Supplier - Westinghouse Energy Systems Europe, Brussels works in cooperation with teams of specialist from both Nuclear Power Plants. In the frame of 'living Probabilistic Safety Assessment-1 Nuclear Power Plant Dukovany Project' being performed by Nuclear Research Institute Rez during 1997 is planned to prove on Probabilistic Safety Assessment -1 basis an expected - positive impact of Emergency Response Guidelines on Plant Safety, Since this contract is currently still in progress, it is possible to release only preliminary conclusions and observations. Emergency Response Guidelines compare to original Emergency Operating Procedures substantially reduce uncertainty of general human behaviour during plant response to an accident process. It is possible to conclude that from the current scope Probabilistic Safety Assessment Dukovany point of view (until core damage), Emergency Response Guidelines represent adequately wide basis for mitigating any initiating event

  3. Developing and implementing health and sustainability guidelines for institutional food service.

    Science.gov (United States)

    Kimmons, Joel; Jones, Sonya; McPeak, Holly H; Bowden, Brian

    2012-05-01

    Health and sustainability guidelines for institutional food service are directed at improving dietary intake and increasing the ecological benefits of the food system. The development and implementation of institutional food service guidelines, such as the Health and Human Services (HHS) and General Services Administration (GSA) Health and Sustainability Guidelines for Federal Concessions and Vending Operations (HHS/GSA Guidelines), have the potential to improve the health and sustainability of the food system. Institutional guidelines assist staff, managers, and vendors in aligning the food environment at food service venues with healthier and more sustainable choices and practices. Guideline specifics and their effective implementation depend on the size, culture, nature, and management structure of an institution and the individuals affected. They may be applied anywhere food is sold, served, or consumed. Changing institutional food service practice requires comprehensive analysis, engagement, and education of all relevant stakeholders including institutional management, members of the food supply chain, and customers. Current examples of food service guidelines presented here are the HHS and GSA Health and Sustainability Guidelines for Federal Concessions and Vending Operations, which translate evidence-based recommendations on health and sustainability into institutional food service practices and are currently being implemented at the federal level. Developing and implementing guidelines has the potential to improve long-term population health outcomes while simultaneously benefitting the food system. Nutritionists, public health practitioners, and researchers should consider working with institutions to develop, implement, and evaluate food service guidelines for health and sustainability.

  4. Classification and Clinical Diagnosis of Fibromyalgia Syndrome: Recommendations of Recent Evidence-Based Interdisciplinary Guidelines

    Directory of Open Access Journals (Sweden)

    Mary-Ann Fitzcharles

    2013-01-01

    Full Text Available Objectives. Fibromyalgia syndrome (FMS, characterized by subjective complaints without physical or biomarker abnormality, courts controversy. Recommendations in recent guidelines addressing classification and diagnosis were examined for consistencies or differences. Methods. Systematic searches from January 2008 to February 2013 of the US-American National Guideline Clearing House, the Scottish Intercollegiate Guidelines Network, Guidelines International Network, and Medline for evidence-based guidelines for the management of FMS were conducted. Results. Three evidence-based interdisciplinary guidelines, independently developed in Canada, Germany, and Israel, recommended that FMS can be clinically diagnosed by a typical cluster of symptoms following a defined evaluation including history, physical examination, and selected laboratory tests, to exclude another somatic disease. Specialist referral is only recommended when some other physical or mental illness is reasonably suspected. The diagnosis can be based on the (modified preliminary American College of Rheumatology (ACR 2010 diagnostic criteria. Discussion. Guidelines from three continents showed remarkable consistency regarding the clinical concept of FMS, acknowledging that FMS is neither a distinct rheumatic nor mental disorder, but rather a cluster of symptoms, not explained by another somatic disease. While FMS remains an integral part of rheumatology, it is not an exclusive rheumatic condition and spans a broad range of medical disciplines.

  5. IAEA/NEA Fuel Incident Notification and Analysis System (FINAS) guidelines

    International Nuclear Information System (INIS)

    2006-01-01

    The Fuel Incident Notification and Analysis System (FINAS) is an international system jointly operated by the International Atomic Energy Agency (IAEA) and the Nuclear Energy Agency of the Organisation for Economic Cooperation and Development (OECD/NEA). The fundamental objective of FINAS is to contribute to improving the safety of fuel cycle facilities, which are operated worldwide. This objective can be achieved by providing timely and detailed information on both technical and human factors related to events of safety significance, which occur at these facilities. The purpose of these guidelines, which supersede the previous NEA FINAS guidelines is to describe the system and to give users the necessary background and guidance to enable them to produce FINAS reports meeting a high standard of quality while retaining the high efficiency of the system expected by all Member States operating FCFs. These guidelines have been jointly developed and approved by the NEA/IAEA

  6. Microbiological evaluation of various parameters in ophthalmic operating rooms. The need to establish guidelines.

    Directory of Open Access Journals (Sweden)

    Kelkar Uday

    2003-01-01

    Full Text Available Purpose: Postoperative infections can be caused by a contaminated environment, unsterile equipment, contaminated surfaces, and infected personnel as well as contaminated disinfectants. In order to establish guidelines for microbiological monitoring, a detailed microbiological surveillance was carried out in an ophthalmic hospital. Method: Over a period of 21 months, we assessed environmental Bacteria Carrying Particle (BCP load and surface samples weekly (n=276; the autoclaving system once a month and repeated whenever the process failed (n= 24; the air conditioning filters for fungal growth once in four months (n = 15, and the disinfectant solution for contamination once in two months (n = 10. Additionally, the personnel involved directly in surgery were screened for potential pathogens such as Staphylococcus aureus and β haemolytic streptococci. Result: On 14 (5.07% occasions the environment in the operating rooms had a significant risk of airborne infections. Sterilisation of instruments in the autoclaves was unsatisfactory on 4 (16.66 % occasions. Samples from the filters of the air-conditioning units yielded potentially pathogenic fungi on 3 (20% occasions. Personnel sampling revealed that 5 (8.77% individuals harboured β haemolytic Streptococci in the throat and 4 (7.01 % harboured S. aureus in the nasal cavity. The samples of disinfectant in use were not contaminated. Conclusion: There is a need to standardise microbiological evaluation protocols for operating rooms.

  7. Cell emulation and preliminary results.

    Science.gov (United States)

    2016-07-01

    This report details preliminary results of the testing plan implemented by the Hawaii Natural Energy Institute to evaluate Electric Vehicle (EV) battery durability and reliability under electric utility grid operations. Commercial EV battery cells ar...

  8. Guidelines for control room design reviews

    International Nuclear Information System (INIS)

    1981-09-01

    The control room design review is part of a broad program being undertaken by the nuclear industry and the government to ensure consideration of human factors in nuclear power plant design and operation. The purpose of the control room design review described by these guidelines is to (1) review and evaluate the control room workspace, instrumentation, controls, and other equipment from a human factors engineering point of view that takes into account both system demands and operator capabilities; and (2) to identify, assess, and implement control room design modifications that correct inadequate or unsuitable items. The scope of the control room design review described by these guidelines covers the human engineering review of completed control rooms; i.e., operational control rooms or those at that stage of the licensing process where control room design and equipment selection are committed. These guidelines should also be of use during the design process for new control rooms. However, additional analyses to optimize the allocation of functions to man and machine, and further examination of advanced control system technology, are recommended for new control rooms. Guidelines and references for comprehensive system analyses designed to incorporate human factors considerations into the design and development of new control rooms are presented in Appendix B. Where possible, a generic approach to the control room design review process is encouraged; for example, when control room designs are replicated wholly or in part in two or more units. Even when designs are not replicated exactly, generic reviews which can be modified to account for specific differences in particular control rooms should be considered. Industry organizations and owners groups are encouraged to coordinate joint efforts and share data to develop generic approaches to the design review process. The control room design review should accomplish the following specific objectives. To determine

  9. Computerization of guidelines: towards a "guideline markup language".

    Science.gov (United States)

    Dart, T; Xu, Y; Chatellier, G; Degoulet, P

    2001-01-01

    Medical decision making is one of the most difficult daily tasks for physicians. Guidelines have been designed to reduce variance between physicians in daily practice, to improve patient outcomes and to control costs. In fact, few physicians use guidelines in daily practice. A way to ease the use of guidelines is to implement computerised guidelines (computer reminders). We present in this paper a method of computerising guidelines. Our objectives were: 1) to propose a generic model that can be instantiated for any specific guidelines; 2) to use eXtensible Markup Language (XML) as a guideline representation language to instantiate the generic model for a specific guideline. Our model is an object representation of a clinical algorithm, it has been validated by running two different guidelines issued by a French official Agency. In spite of some limitations, we found that this model is expressive enough to represent complex guidelines devoted to diabetes and hypertension management. We conclude that XML can be used as a description format to structure guidelines and as an interface between paper-based guidelines and computer applications.

  10. European Society of Endocrinology Clinical Practice Guideline for long-term follow-up of patients operated on for a phaeochromocytoma or a paraganglioma.

    Science.gov (United States)

    Plouin, P F; Amar, L; Dekkers, O M; Fassnacht, M; Gimenez-Roqueplo, A P; Lenders, J W M; Lussey-Lepoutre, C; Steichen, O

    2016-05-01

    Phaeochromocytomas and paragangliomas (PPGLs) are rare neuroendocrine tumours. Standard treatment is surgical resection. Following complete resection of the primary tumour, patients with PPGL are at risk of developing new tumoural events. The present guideline aims to propose standardised clinical care of long-term follow-up in patients operated on for a PPGL. The guideline has been developed by The European Society of Endocrinology and based on the Grading of Recommendations Assessment, Development and Evaluation (GRADE) principles. We performed a systematic review of the literature and analysed the European Network for the Study of Adrenal Tumours (ENS@T) database. The risk of new events persisted in the long term and was higher for patients with genetic or syndromic diseases. Follow-up in the published cohorts and in the ENS@T database was neither standardised nor exhaustive, resulting in a risk of follow-up bias and in low statistical power beyond 10 years after complete surgery. To inform patients and care providers in this context of low-quality evidence, the Guideline Working Group therefore prepared recommendations on the basis of expert consensus. Key recommendations are the following: we recommend that all patients with PPGL be considered for genetic testing; we recommend assaying plasma or urinary metanephrines every year to screen for local or metastatic recurrences or new tumours; and we suggest follow-up for at least 10 years in all patients operated on for a PPGL. High-risk patients (young patients and those with a genetic disease, a large tumour and/or a paraganglioma) should be offered lifelong annual follow-up. © 2016 European Society of Endocrinology.

  11. Example of severe accident management guidelines validation and verification using full scope simulator

    International Nuclear Information System (INIS)

    Krajnc, B.; Basic, I.; Spiler, J.

    2001-01-01

    The purpose of Severe Accident Management Guidelines (SAMG) is to provide guidelines to mitigate and control beyond design bases accidents. These guidelines are to be used by the technical support center that is established at the plant within one hour after the beginning of the accident as a technical support for the main control room operators. Since some of the accidents can progress very fast there are also two guidelines provided for the main control room operators. The first one is to be used if the core damage occurs and the TSC is not established yet and the second one after technical support center become operational. After SG replacement and power uprate in year 2000, NPP Krsko developed Rev.1 of these procedures, which have been validated and verified during one-week effort. Plant specific simulator capable of simulating severe accidents was extensively used.(author)

  12. K-Basins design guidelines

    International Nuclear Information System (INIS)

    Roe, N.R.; Mills, W.C.

    1995-06-01

    The purpose of the design guidelines is to enable SNF and K Basin personnel to complete fuel and sludge removal, and basin water mitigation by providing engineering guidance for equipment design for the fuel basin, facility modifications (upgrades), remote tools, and new processes. It is not intended to be a purchase order reference for vendors. The document identifies materials, methods, and components that work at K Basins; it also Provides design input and a technical review process to facilitate project interfaces with operations in K Basins. This document is intended to compliment other engineering documentation used at K Basins and throughout the Spent Nuclear Fuel Project. Significant provisions, which are incorporated, include portions of the following: General Design Criteria (DOE 1989), Standard Engineering Practices (WHC-CM-6-1), Engineering Practices Guidelines (WHC 1994b), Hanford Plant Standards (DOE-RL 1989), Safety Analysis Manual (WHC-CM-4-46), and Radiological Design Guide (WHC 1994f). Documents (requirements) essential to the engineering design projects at K Basins are referenced in the guidelines

  13. Biomedical programs operations plans

    Science.gov (United States)

    Walbrecher, H. F.

    1974-01-01

    Operational guidelines for the space shuttle life sciences payloads are presented. An operational assessment of the medical experimental altitude test for Skylab, and Skylab life sciences documentation are discussed along with the operations posture and collection of space shuttle operational planning data.

  14. Health physics appraisal guidelines for fusion/confinement devices

    International Nuclear Information System (INIS)

    Neeson, P.M.

    1987-01-01

    Several types of fusion/confinement devices have been developed for a variety of research applications. The health physics considerations for these devices can vary, depending on a number of parameters. This paper presents guidelines for health physics appraisal of such devices, which can be tailored to apply to specific systems. The guidelines can also be useful for establishing ongoing health physics programs for safe operation of the devices

  15. Developing and Implementing Health and Sustainability Guidelines for Institutional Food Service123

    Science.gov (United States)

    Kimmons, Joel; Jones, Sonya; McPeak, Holly H.; Bowden, Brian

    2012-01-01

    Health and sustainability guidelines for institutional food service are directed at improving dietary intake and increasing the ecological benefits of the food system. The development and implementation of institutional food service guidelines, such as the Health and Human Services (HHS) and General Services Administration (GSA) Health and Sustainability Guidelines for Federal Concessions and Vending Operations (HHS/GSA Guidelines), have the potential to improve the health and sustainability of the food system. Institutional guidelines assist staff, managers, and vendors in aligning the food environment at food service venues with healthier and more sustainable choices and practices. Guideline specifics and their effective implementation depend on the size, culture, nature, and management structure of an institution and the individuals affected. They may be applied anywhere food is sold, served, or consumed. Changing institutional food service practice requires comprehensive analysis, engagement, and education of all relevant stakeholders including institutional management, members of the food supply chain, and customers. Current examples of food service guidelines presented here are the HHS and GSA Health and Sustainability Guidelines for Federal Concessions and Vending Operations, which translate evidence-based recommendations on health and sustainability into institutional food service practices and are currently being implemented at the federal level. Developing and implementing guidelines has the potential to improve long-term population health outcomes while simultaneously benefitting the food system. Nutritionists, public health practitioners, and researchers should consider working with institutions to develop, implement, and evaluate food service guidelines for health and sustainability. PMID:22585909

  16. Guidelines for District Heating Substations

    Energy Technology Data Exchange (ETDEWEB)

    2009-07-15

    The present guidelines contain a set of recommendations focusing on planning, installation, use and maintenance of district heating (DH) substations within district heating systems throughout Europe. The recommendations were developed in order to enable readers to develop well-functioning substations and an effective heat and domestic warm water delivery. These guidelines are intended to give the most effective overall solutions for various parts of the customer installation. The guidelines are not meant to specify the different components of the substation such as meters or heat exchangers. The guidelines deal with a wide variety of issues concerning both present systems of today and district heating systems of the future. Specific handling and maintenance recommendations are mainly focused on present modern systems but are also intended to cover the future situation as much as is feasible. For this reason, certain existing systems are not dealt with in these guidelines. For instance, these guidelines do not cover steam systems, systems with temperatures exceeding 110 deg C and pressure levels above 1.6 MPa. The guidelines include a chapter on the heat meter, as the meter and especially the meter installation is always installed simultaneously with the rest of the substation. These guidelines aim to provide best-practice and easy-to-handle recommendations for: - those who are responsible for relations between district heating utilities and customers; - those who own or maintain a building connected to the district heating network; - those who manufacture, plan, purchase, test and install substations. These guidelines do not deal with investment or cost aspects, but in general, Euroheat and Power recommends looking at the lifetime cost of all components of the substation, instead of investment costs alone. An example of this is provided in Chapter 7.8. The Guidelines were developed based on the most optimal operating principles of substations and meters

  17. Proposed DoD Guidelines for Implementation of a Web-Based Joint IETM Architecture (JIA) to Assure the Interoperability of DoD IETMs

    National Research Council Canada - National Science Library

    Jorgensen, Eric L

    1999-01-01

    This Paper presents preliminary guidelines intended to serve as input to a planned DoD Handbook for the Acquisition and Deployment of DoD IETMs with the specific purpose of assuring interoperability...

  18. Preliminary assessment of the Louisiana Home Energy Rebate Offer program using IPMVP guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Kaiser, Mark J.; Pulsipher, Allan G. [Center for Energy Studies, Louisiana State University, Energy Coast and Environment Building, Nicholson Extension Drive, Baton Rouge, LA 70803 (United States)

    2010-02-15

    The Louisiana Home Energy Rebate Offer (HERO) is a residential energy conservation program established in 1999 to provide rebates for qualified applicants to build new homes that are more energy efficient or improve the energy efficiency of existing homes. Energy conservation programs require careful evaluation because of the high cost to implement the measures and the expectation that they will reduce energy use. The purpose of this paper is to demonstrate that residential energy conservation measures in a hot and humid climate can be evaluated using the International Performance Measurement and Verification Protocol (IPMVP), a best practice methodology commonly used in industrial and commercial performance-based contracts, but rarely, if ever, applied to residential programs. Using a random sample of 60 HERO participants, we were able to construct statistically significant electricity consumption baseline models for 90% of households. We determined that more than half of the sample participants consumed more electricity after their efficiency improvement, with an average net household savings of 172 kWh/yr, about 1% pre-retrofit consumption. A description of the baseline model construction, preliminary program evaluation, and recommendations are provided. All program conclusions are considered preliminary until a larger and more comprehensive study is conducted. (author)

  19. Preliminary assessment of the Louisiana Home Energy Rebate Offer program using IPMVP guidelines

    International Nuclear Information System (INIS)

    Kaiser, Mark J.; Pulsipher, Allan G.

    2010-01-01

    The Louisiana Home Energy Rebate Offer (HERO) is a residential energy conservation program established in 1999 to provide rebates for qualified applicants to build new homes that are more energy efficient or improve the energy efficiency of existing homes. Energy conservation programs require careful evaluation because of the high cost to implement the measures and the expectation that they will reduce energy use. The purpose of this paper is to demonstrate that residential energy conservation measures in a hot and humid climate can be evaluated using the International Performance Measurement and Verification Protocol (IPMVP), a best practice methodology commonly used in industrial and commercial performance-based contracts, but rarely, if ever, applied to residential programs. Using a random sample of 60 HERO participants, we were able to construct statistically significant electricity consumption baseline models for 90% of households. We determined that more than half of the sample participants consumed more electricity after their efficiency improvement, with an average net household savings of 172 kWh/yr, about 1% pre-retrofit consumption. A description of the baseline model construction, preliminary program evaluation, and recommendations are provided. All program conclusions are considered preliminary until a larger and more comprehensive study is conducted.

  20. Preliminary Assessment of Potential Avian Interactions at Four Proposed Wind Energy Facilities on Vandenberg Air Force Base, California

    Energy Technology Data Exchange (ETDEWEB)

    2004-08-01

    The United States Air Force (USAF) is investigating whether to install wind turbines to provide a supplemental source of electricity at Vandenberg Air Force Base (VAFB) near Lompoc, California. As part of that investigation, VAFB sought assistance from the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to provide a preliminary characterization of the potential risk to wildlife resources (mainly birds and bats) from wind turbine installations. With wind power development expanding throughout North America and Europe, concerns have surfaced over the number of bird fatalities associated with wind turbines. Guidelines developed for the wind industry by the National Wind Coordinating Committee (NWCC) recommend assessing potential impacts to birds, bats, and other potentially sensitive resources before construction. The primary purpose of an assessment is to identify potential conflicts with sensitive resources, to assist developers with identifying their permitting needs, and to develop strategies to avoid impacts or to mitigate their effects. This report provides a preliminary (Phase I) biological assessment of potential impacts to birds and bats that might result from construction and operation of the proposed wind energy facilities on VAFB.

  1. Guidelines to Facilitate the Evaluation of Brines for Winter Roadway Maintenance Operations.

    Science.gov (United States)

    2017-09-19

    This document presents guidelines to facilitate the evaluation of brines for winter weather roadway maintenance applications in Texas. Brines are used in anti-icing applications which typically consist of placing liquid snow and ice control chemicals...

  2. 78 FR 57319 - Children's Online Privacy Protection Rule Safe Harbor Proposed Self-Regulatory Guidelines...

    Science.gov (United States)

    2013-09-18

    ...-AB20 Children's Online Privacy Protection Rule Safe Harbor Proposed Self-Regulatory Guidelines; kidSAFE... proposed self-regulatory guidelines submitted by the kidSAFE Seal Program (``kidSAFE''), owned and operated... enabling industry groups or others to submit to the Commission for approval self-regulatory guidelines that...

  3. Guideline for safe and eco-friendly biomass gasification

    Energy Technology Data Exchange (ETDEWEB)

    Vos, J.; Knoef, H. (BTG biomass technology group, Enschede (Netherlands)); Hauth, M. (Graz Univ. of Technology. Institute of Thermal Engineering, Graz (Austria)) (and others)

    2009-11-15

    The objective of the Gasification Guide project is to accelerate the market penetration of small-scale biomass gasification systems (< 5 MW fuel power) by the development of a Guideline and Software Tool to facilitate risk assessment of HSE aspects. The Guideline may also be applied in retrofitting or converting old thermal plants in the Eastern European countries - with rich biomass recourses - to new gasification plants. The objective of this document is to guide key target groups identifying potential hazards and make a proper risk assessment. The software tool is an additional aid in the risk assessment. This guideline is intended to be a training tool and a resource for workers and employers to safely design, fabricate, construct, operate and maintain small-scale biomass gasification facilities. The Guideline is applicable with the following constraints: 1) The maximum scale of the gasification plant was agreed to be about 1 MW{sub e}. The reason is that large companies do have normally their safety rules in place; 2) This means in principle only fixed bed gasifier designs. However, most parts are also valid to other designs and even other thermal conversion processes; 3) The use of contaminated biomass is beyond the scope of this Guideline. The Guideline contains five major chapters; Chapter 2 briefly describes the gasification technology in general. Chapter 3 gives an overview of major legal framework issues on plant permission and operation. The legal frame is changing and the description is based on the situation by the end of 2007. Chapter 4 explains the theory behind the risk assessment method and risk reduction measures. Chapter 5 is the heart of the Guideline and gives practical examples of good design, operation and maintenance principles. The practical examples and feedback have been received throughout the project and the description is based on mid-2009. Chapter 6 describes the best techniques currently available for emission abatement which are

  4. Soil and groundwater remediation guidelines for methanol

    International Nuclear Information System (INIS)

    2010-12-01

    Methanol is used by oil and gas operators to inhibit hydrate formation in the recovery of heavy oils, in natural gas production and transport, as well as in various other production applications. Emissions from methanol primary occur from miscellaneous solvent usage, methanol production, end-product manufacturing, and storage and handling losses. This document provided soil and groundwater remediation guidelines for methanol releases into the environment. The guidelines were consistent with the Alberta Environment tier 1 soil and groundwater framework. The chemical and physical properties of methanol were reviewed. The environmental fate and behavior of methanol releases was discussed, and the behaviour and effects of methanol in terrestrial and aquatic biota were evaluated. The toxicity of methanol and its effects in humans and mammalian species were reviewed. Soil quality and ground water quality guidelines were presented. Surface water and soil guideline calculation methods were provided, and ecological exposure and ground water pathways were discussed. Management limits for methanol concentrations were also provided. 162 refs., 18 tabs., 4 figs.

  5. Exploring Bim for Operational Integrated Asset Management - a Preliminary Study Utilising Real-World Infrastructure Data

    Science.gov (United States)

    Boyes, G. A.; Ellul, C.; Irwin, D.

    2017-10-01

    The use of 3D information models within collaborative working environments and the practice of Building Information Modelling (BIM) are becoming more commonplace within infrastructure projects. Currently used predominantly during the design and construction phase, the use of BIM is capable in theory of providing the information at handover that will satisfy the Asset Information Requirements (AIRs) of the future Infrastructure Manager (IM). One particular challenge is establishing a link between existing construction-centric information and the asset-centric information needed for future operations. Crossrail, a project to build a new high-frequency railway underneath London, is handling many such challenges as they prepare to handover their digital information to the future operator, in particular the need to provide a two-way link between a federated 3D CAD model and an object-relational Asset Information Management System (AIMS). This paper focusses on the potential for improved Asset Management (AM) by integrating BIM and GIS systems and practices, and makes a preliminary report on how 3D spatial queries can be used to establish a two-way relational link between two information systems (3D geometry and asset lists), as well as the challenges being overcome to transform the data to be suitable for AM.

  6. Technical guideline technology according to the X-ray regulations

    International Nuclear Information System (INIS)

    2011-01-01

    The guideline covers the required technical knowledge concerning radiation protection and knowledge concerning for the operation of X-ray devices for technical purposes and stray radiation sources requiring licensing, and requirements for the qualification of officially authorized inspectors. The guidelines includes the following chapters: (1) introductory regulations; (2) Volume of the required technical knowledge; (3) Acquirement and certification of the technical knowledge; (4) Actualization of the technical knowledge; (5)Approval of courses and other training measures; (6) Combination of courses and training measures according to the guideline; (7) Requirements for qualification of officially authorized inspectors; (8) Interim regulations.

  7. 10 CFR 436.102 - General operations plan format and content.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false General operations plan format and content. 436.102... PROGRAMS Guidelines for General Operations Plans § 436.102 General operations plan format and content. (a... effective date of these guidelines, a general operations 10-year plan which shall consist of two parts, an...

  8. Electromagnetic impact by microcellular base stations: analysis and guidelines for a correct setting up

    International Nuclear Information System (INIS)

    Licitra, G.; Reggiani, M.; Silvi, A.M.; Zari, A.; Ricci, A.

    2002-01-01

    During the last few years the development of mobile communications has required ever increasing number of base stations for both existing mobile operators and new ones. More and more users ask for a higher quality services so new technological solutions have been studied and applied to assure effective coverage for given geographical areas, as in squares or narrow streets, characterized by a very high traffic demand or where coverage by usual macro cells is very difficult. On the other side, modern societies of developed countries ask for a better and better quality of life and appropriate government policies. Several studies of national and international scientific organizations have been performed and are still in progress to establish any possible adverse effects on human health of non-ionizing radiation exposure. So, many governments, forced by public opinion pressure, have produced specific standards in agreement with scientific organization guidelines and prudent avoidance politics too. Nowadays, designing their networks, mobile operators have to respect requirements contained in these standards. So a hierarchical cellular system have been recently proposed to comply more easily with both coverage requirements and lower exposure limits. This new coverage strategy of geographical areas requires the presence of microcells beside the usual macro cells. In this paper the study of the distribution of the electromagnetic field levels produced by microcellular base stations characterized by different features and configurations is presented, in order to define a few guidelines for the correct setting up of antennas in compliance with current standard requirements. This is obtained comparing results of theoretical modeling, based on the radio electrical characteristics of each sources, and measurements data. Results achieved by measurements performed on a preliminary sample of microcells have been presented in this work

  9. International guidelines for prevention and management of post-operative chronic pain following inguinal hernia surgery

    DEFF Research Database (Denmark)

    Alfieri, S; Amid, P K; Campanelli, G

    2011-01-01

    To provide uniform terminology and definition of post-herniorrhaphy groin chronic pain. To give guidelines to the scientific community concerning the prevention and the treatment of chronic groin and testicular pain.......To provide uniform terminology and definition of post-herniorrhaphy groin chronic pain. To give guidelines to the scientific community concerning the prevention and the treatment of chronic groin and testicular pain....

  10. Deriving cleanup guidelines for radionuclides at Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Meinhold, A.F.; Morris, S.C.; Dionne, B.; Moskowitz, P.D.

    1997-01-01

    Past activities at Brookhaven National Laboratory (BNL) resulted in soil and groundwater contamination. As a result, BNL was designated a Superfund site under the Comprehensive Environmental Response Compensation and Liability Act (CERCLA). BNL`s Office of Environmental Restoration (OER) is overseeing environmental restoration activities at the Laboratory. With the exception of radium, there are no regulations or guidelines to establish cleanup guidelines for radionuclides in soils at BNL. BNL must derive radionuclide soil cleanup guidelines for a number of Operable Units (OUs) and Areas of Concern (AOCs). These guidelines are required by DOE under a proposed regulation for radiation protection of public health and the environment as well as to satisfy the requirements of CERCLA. The objective of this report is to propose a standard approach to deriving risk-based cleanup guidelines for radionuclides in soil at BNL. Implementation of the approach is briefly discussed.

  11. Deriving cleanup guidelines for radionuclides at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Meinhold, A.F.; Morris, S.C.; Dionne, B.; Moskowitz, P.D.

    1997-01-01

    Past activities at Brookhaven National Laboratory (BNL) resulted in soil and groundwater contamination. As a result, BNL was designated a Superfund site under the Comprehensive Environmental Response Compensation and Liability Act (CERCLA). BNL's Office of Environmental Restoration (OER) is overseeing environmental restoration activities at the Laboratory. With the exception of radium, there are no regulations or guidelines to establish cleanup guidelines for radionuclides in soils at BNL. BNL must derive radionuclide soil cleanup guidelines for a number of Operable Units (OUs) and Areas of Concern (AOCs). These guidelines are required by DOE under a proposed regulation for radiation protection of public health and the environment as well as to satisfy the requirements of CERCLA. The objective of this report is to propose a standard approach to deriving risk-based cleanup guidelines for radionuclides in soil at BNL. Implementation of the approach is briefly discussed

  12. Guidelines for safe process operations and maintenance

    CERN Document Server

    2010-01-01

    First-line managers have to maintain the integrity of facilities, control manufacturing processes, and handle unusual or emergency situations, as well as respond to the pressures of production demand. On a daily basis, they are closest to the operating personnel who may be injured by a process accident, and they are in the best position to spot problem conditions and to act to contain them. This book offers these managers ""how-to"" information on process safety management program execution in the operations and maintenance departments, recommending technical and administrative process safety

  13. Guidelines for water and steam adapted to Swedish energy plants; Riktvaerden foer vatten och aanga anpassade till svenska energianlaeggningar

    Energy Technology Data Exchange (ETDEWEB)

    Hellman, Mats [Hellman Vatten AB, Haegersten (Sweden)

    2006-02-15

    The project summons a revision of the Swedish Cycle Chemistry Guidelines with the purpose to create guidelines that are more explicit and thereby easier to adapt to in daily operations. The objective in general has not been to tighten the limiting values; some are stricter but some others are less strict. The boilers of today are usually fed with demineralised water as make-up water which has been reflected in the guidelines. In this project consideration has been taken upon the fact that many boilers, mostly industrial, have been in operation for many years according to old guidelines, without problems. In these cases the boilers may very well continue to operate without any costly reinvestments due to the new guidelines. The most important revisions in the guidelines are: Action levels have been introduced for the core parameters in the water-steam cycle. With action levels the operators will have some guidance to correct deviations in the cycle chemistry. The action levels are progressive in the sense that the more serious deviation from the guidelines, the shorter time to correct the problem. Guidelines for boilers up to 6.0 MPa operating on softened make-up water have been adjusted slightly and introduced with action levels. New guidelines for boilers with demineralised make-up water have been compiled. Within the project group there is a consensus that demineralised make-up water is preferable even for low pressure boilers. Varying chemistry regimes are used in the industry today. This report gives guidelines for the three dominating in Sweden; All Volatile Treatment (AVT), Caustic Treatment and Phosphate Treatment. Cation conductivity is a core parameter for supervision of steam quality for turbine operation, and in all international guidelines cation conductivity is included. However, the cation conductivity can rise above limits if organic dosing agents are used. This may be accepted as long as the pH-value is within the specifications and it can be shown

  14. Guideline for the erection of wind power plants

    International Nuclear Information System (INIS)

    Behnke, R.; Kampet, T.

    1990-01-01

    This guideline for the erection of a proper wind power plant is to give hints on some important stations on the way from the idea up to perfect operation of the plant. This guideline, however, does not substitute the professional knowledge of a consulting company or firm neutral to manufacturing. Such firms are listed in an attached list of addresses at the end. When establishing this guideline possible problems which occur in the utilization of wind energy have been considered. These items which in some cases seem to be very problematic should not prevent anybody to trust in the application of wind energy wherever it is economically justified or ecologically useful. (orig./BWI) [de

  15. Preliminary waste acceptance requirements for the planned Konrad repository

    International Nuclear Information System (INIS)

    Warnecke, E.; Brennecke, P.

    1987-01-01

    The Physikalisch-Technische Bundesanstalt (PTB) has established Preliminary Waste Acceptance Requirements for the planned Konrad repository. These requirements were developed, in accordance with the Safety Criteria of the Reactor Safety Commission, with the help of a site specific safety assessment; they are under the reservation of the plan approval procedure, which is still in progress. In developing waste acceptance requirements, the PTB fulfills one of its duties as the institute responsible for waste disposal and gives guidelines for waste conditioning to waste producers and conditioners. (orig.) [de

  16. Resuscitation outcomes comparing year 2000 with year 2005 ALS guidelines in a pig model of cardiac arrest.

    Science.gov (United States)

    Xanthos, Theodoros; Tsirikos-Karapanos, Nikolas; Papadimitriou, Dimitrios; Vlachos, Ioannis S; Tsiftsi, Katerina; Ekmektzoglou, Konstantinos A; Papadimitriou, Lila

    2007-06-01

    Ventricular fibrillation remains the leading cause of death in western societies. International organizations publish guidelines to follow in case of cardiac arrest. The aim of the present study is to assess whether the newly published guidelines record similar resuscitation success with the 2000 Advanced Life Support Guidelines on Resuscitation in a swine model of cardiac arrest. Nineteen landrace/large white pigs were used. Ventricular fibrillation was induced with the use of a transvenous pacing wire inserted into the right ventricle. The animals were randomized into two groups. In Group A, 10 animals were resuscitated using the 2000 guidelines, whereas in Group B, 9 animals were resuscitated using the 2005 guidelines. Both algorithms recorded similar successful resuscitation rates, as 60% of the animals in Group A and 44.5% in Group B were successfully resuscitated. However, animals in Group A restored a rhythm, compatible with a pulse, quicker than those in Group B (p=0.002). Coronary perfusion pressure (CPP) was not adversely affected by three defibrillation attempts in Group A. Both algorithms' resulted in comparable resuscitation success, however, guidelines 2000 resulted in faster resuscitation times. These preliminary results merit further investigation.

  17. Advanced control room design review guidelines: Merging old and new

    International Nuclear Information System (INIS)

    Carter, R.J.; Wachtel, J.A.

    1992-01-01

    The nuclear power industry is currently developing operator interface systems based on innovative applications of digital computers. To assure that this advanced technology is incorporated in a way that maximizes the potential safety benefits of the technology and minimizes the potential negative effects on human performance, human factors principles must be considered. NUREG-0700 contains guidelines for the review of operator interfaces. However, in light of the rapid technological advances in digital technology which have taken place in the eleven years since its publication, it is no longer adequate to assess the rapidly changing human-system interfaces. A research program, the purpose of which is to upgrade NUREG-0700, has been initiated. Thus far a set of draft advanced control room design review (ACRDR) guidelines has been complied. Three tasks, which were oriented towards integrating the applicable guidelines in NUREG-0700 into the ACRDR document, are described in the paper

  18. Implementing shared decision making in federally qualified health centers, a quasi-experimental design study: the Office-Guidelines Applied to Practice (Office-GAP) program

    OpenAIRE

    Olomu, Adesuwa; Hart-Davidson, William; Luo, Zhehui; Kelly-Blake, Karen; Holmes-Rovner, Margaret

    2016-01-01

    Background Use of Shared Decision-Making (SDM) and Decision Aids (DAs) has been encouraged but is not regularly implemented in primary care. The Office-Guidelines Applied to Practice (Office-GAP) intervention is an application of a previous model revised to address guidelines based care for low-income populations with diabetes and coronary heart disease (CHD). Objective: To evaluate Office-GAP Program feasibility and preliminary efficacy on medication use, patient satisfaction with physician ...

  19. Guidelines to Career Development for Wastewater Treatment Plant Personnel.

    Science.gov (United States)

    Environmental Protection Agency, Washington, DC. Office of Education and Manpower Planning.

    The guidelines were written to promote job growth and improvement in the personnel who manage, operate, and maintain wastewater treatment plants. Trained operators and technicians are the key components in any water pollution control facility. The approach is to move from employment to training through specific modules for 21 standard job…

  20. Assessment of EPRI water chemistry guidelines for new nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, K.; Fruzzetti, K.; Garcia, S. [Electric Power Research Inst., Palo Alto, California (United States); Eaker, R. [Richard W. Eaker, LLC, Matthews, North Carolina (United States); Giannelli, J.; Tangen, J. [Finetech, Inc., Parsippany, New Jersey (United States); Gorman, J.; Marks, C. [Dominion Engineering, Inc., Reston, Virginia (United States); Sawochka, S. [NWT Corp., San Jose, California (United States)

    2010-07-01

    Water chemistry control technologies for nuclear power plants have been significantly enhanced over the past few decades to improve material and equipment reliability and fuel performance, and to minimize radionuclide production and transport. Chemistry Guidelines have been developed by the Electric Power Research Institute (EPRI) for current operating plants and have been intermittently revised over the past twenty-five years for the protection of systems and components and for radiation management. As new plants are being designed for improved safety and increased power production, it is important to ensure that the designs consider implementation of industry approved water chemistry controls. In parallel, the industry will need to consider and develop updated water chemistry guidelines as well as plant startup and operational strategies based on the advanced plant designs. In 2010, EPRI began to assess chemistry control strategies at advanced plants, based on the Design Control Documents (DCDs), Combined Construction and Operating License Applications (COLA), and operating experiences (where they exist) against current Water Chemistry Guidelines. Based on this assessment, differences between planned chemistry operations at new plants and the current Guidelines will be identified. This assessment will form the basis of future activities to address these differences. The project will also assess and provide, as feasible, water chemistry guidance for startup and hot functional testing of the new plants. EPRI will initially assess the GE-Hitachi/Toshiba ABWR and the Westinghouse AP1000 designs. EPRI subsequently plans to assess other plant designs such as the AREVA U.S. EPR, Mitsubishi Heavy Industries (MHI) U.S. APWR, and GE-Hitachi (GE-H) ESBWR. This paper discusses the 2010 assessments of the ABWR and AP1000. (author)

  1. Assessment of EPRI water chemistry guidelines for new nuclear power plants

    International Nuclear Information System (INIS)

    Kim, K.; Fruzzetti, K.; Garcia, S.; Eaker, R.; Giannelli, J.; Tangen, J.; Gorman, J.; Marks, C.; Sawochka, S.

    2010-01-01

    Water chemistry control technologies for nuclear power plants have been significantly enhanced over the past few decades to improve material and equipment reliability and fuel performance, and to minimize radionuclide production and transport. Chemistry Guidelines have been developed by the Electric Power Research Institute (EPRI) for current operating plants and have been intermittently revised over the past twenty-five years for the protection of systems and components and for radiation management. As new plants are being designed for improved safety and increased power production, it is important to ensure that the designs consider implementation of industry approved water chemistry controls. In parallel, the industry will need to consider and develop updated water chemistry guidelines as well as plant startup and operational strategies based on the advanced plant designs. In 2010, EPRI began to assess chemistry control strategies at advanced plants, based on the Design Control Documents (DCDs), Combined Construction and Operating License Applications (COLA), and operating experiences (where they exist) against current Water Chemistry Guidelines. Based on this assessment, differences between planned chemistry operations at new plants and the current Guidelines will be identified. This assessment will form the basis of future activities to address these differences. The project will also assess and provide, as feasible, water chemistry guidance for startup and hot functional testing of the new plants. EPRI will initially assess the GE-Hitachi/Toshiba ABWR and the Westinghouse AP1000 designs. EPRI subsequently plans to assess other plant designs such as the AREVA U.S. EPR, Mitsubishi Heavy Industries (MHI) U.S. APWR, and GE-Hitachi (GE-H) ESBWR. This paper discusses the 2010 assessments of the ABWR and AP1000. (author)

  2. The effect of implementing a new guideline and operative pro forma on the detection and management of third- and fourth-degree perineal tears

    Directory of Open Access Journals (Sweden)

    Cornell K

    2016-05-01

    Full Text Available Kristin Cornell,1 Alison De Souza,2 Mark Tacey,3 David M Long,4 Mayooran Veerasingham5 1Department of Obstetrics and Gynaecology, The Northern Hospital, Epping, VIC, 2Department of Urogynecology, Mercy Hospital for Women, Melbourne, VIC, 3Northern Clinical Research Centre, The Northern Hospital and Department of Medicine, University of Melbourne, Melbourne, VIC, 4Department of Emergency Medicine, The Austin Hospital, Melbourne, VIC, 5The Department of Obstetrics and Gynaecology, Ipswich General Hospital, Ipswich, QLD, Australia Background: Obstetric anal sphincter injury (OASI is a serious complication of vaginal births, resulting in possible long-term consequences such as incontinence and pain. Adequate detection and management of these injuries is vital in minimizing the impact they have on women. Aim: To assess the rates of detection, management, and outcomes of OASI before and after the implementation of a new clinical practice guideline and operative pro forma. Materials and methods: A 12-month audit of the incidence, management, and outcomes of OASI was conducted in 2009. An operative pro forma and practice guideline were implemented in 2010 followed by a further audit undertaken between 2010 and 2012. Statistical analysis was performed to determine any significant change in practice. Results: The distribution of risk factors for OASI including primiparity, birthweight, and type of vaginal delivery was similar between the two audited groups. After implementation of the pro forma, the reported incidence of OASI increased from 1.62% to 3.1% (P=0.004. Significant changes in management included an increase in the use of recommended suture material (48% vs 80%, P=0.002, postoperative antibiotics (78% vs 99%, P=0.001, postoperative catheterization (52% vs 90%, P<0.001, and inpatient physiotherapy consultations (44% vs 97%, P=<0.001. An increase was seen in women attending their 6-week follow-up appointment (33% vs 54% P=0.058; however, this was

  3. Identifying Problems in Students’ Final Projects Based on Scientific Writing Guidelines

    Directory of Open Access Journals (Sweden)

    Endang Ernawati

    2010-11-01

    Full Text Available Article analyzed student’s difficulties and abilities in writing their final projects, which were undergraduate theses and undergraduate paper conducted by some students at the English Department, Bina Nusantara University. This was a preliminary study to support an appropriate student guideline in writing their final project. The study was conducted by applying qualitative methods that was by analyzing the four theses and one paper in terms of their format: titles, introduction, theoretical background, analysis, conclusion, bibliography, and paper rubric to analyze the contents. It can be concluded that generally, students, guided by their mentor/lecturer, understand the final paper guidelines and they are able to apply it in their thesis and paper. But, there are still lack of clarity and relevancy in expressing their ideas properly, and their ability in writing in both English and Bahasa Indonesia must be improved. These problems can be overcome by socializing the writing guidelines to both students and lecturers, providing them with critical thinking skills, cooperation with library that will guide them in information literacy skills, and language center that will improve their writing skills. 

  4. Human factors guidelines for large-screen displays

    International Nuclear Information System (INIS)

    Collier, Steve

    2005-09-01

    Any control-room project (including upgrades or evolutionary improvements to existing control-rooms) is well advised at the outset first to gather and update related background material for the design. This information-gathering exercise should also take into account experience from similar projects and operating experience. For these reasons, we decided to use our research, and experience in large-screen display design with several clients to update human factors guidance for large-screen displays, to take into account new ergonomics guidelines, operating experience, and work from similar projects. To write the updated guidelines, we drew on much of our experience across several departments at IFE, including research funded by the HRP programme, and experience with individual clients. Guidance here is accordingly focused mainly on recent areas of technical and human innovations in the man-machine interface. One particular area of focus was on the increasing use of large-screen display systems in modern control-rooms, and on how guidelines could be adapted and supplemented for their design. Guidance or reference to recommended sources is also given for control suite arrangement and layout, control-room layout, workstation layout, design of displays and controls, and design of the work environment, especially insofar as these ergonomic issues interact with the effectiveness of modern displays, in particular large screen displays. The work shows that there can be synergy between HRP research and bilateral activities: the one side offers a capability to develop tools and guidelines, while the other side gives an opportunity to test and refine these in practice, to the benefit of both parties. (Author)

  5. Human factors guidelines for large-screen displays

    Energy Technology Data Exchange (ETDEWEB)

    Collier, Steve

    2005-09-15

    Any control-room project (including upgrades or evolutionary improvements to existing control-rooms) is well advised at the outset first to gather and update related background material for the design. This information-gathering exercise should also take into account experience from similar projects and operating experience. For these reasons, we decided to use our research, and experience in large-screen display design with several clients to update human factors guidance for large-screen displays, to take into account new ergonomics guidelines, operating experience, and work from similar projects. To write the updated guidelines, we drew on much of our experience across several departments at IFE, including research funded by the HRP programme, and experience with individual clients. Guidance here is accordingly focused mainly on recent areas of technical and human innovations in the man-machine interface. One particular area of focus was on the increasing use of large-screen display systems in modern control-rooms, and on how guidelines could be adapted and supplemented for their design. Guidance or reference to recommended sources is also given for control suite arrangement and layout, control-room layout, workstation layout, design of displays and controls, and design of the work environment, especially insofar as these ergonomic issues interact with the effectiveness of modern displays, in particular large screen displays. The work shows that there can be synergy between HRP research and bilateral activities: the one side offers a capability to develop tools and guidelines, while the other side gives an opportunity to test and refine these in practice, to the benefit of both parties. (Author)

  6. Guidelines for training and qualification of radiological protection technicians

    International Nuclear Information System (INIS)

    1987-08-01

    These guidelines, used in combination with plant-specific job analysis, provide the framework for a training and qualification program for radiological protection technicians at nuclear power plants. Radiological protection technicians are defined as those individuals, both plant and contractor, who will be engaged in the evaluation of radiological conditions in the nuclear plant and the implementation of the necessary radiological safety measures as they apply to nuclear plant workers and members of the general public. An important aspect of this work is recognizing and handling unusual situations involving radioactivity, including incidents related to degraded core conditions. These guidelines incorporate the results of an industry-wide job analysis and task analysis (JTA) combined with industry operating experience review. However, the industry-wide analyses did not identify all important academic and fundamental knowledge and skills. Further in-depth analysis by subject matter experts produced additional knowledge and skills that were added to these guidelines. All utilities should use these guidelines in conjunction with plant-specific and industry-wide JTA results to develop or validate their radiological protection technician training program. Plant-specific information should be used to establish appropriate training program content. This plant-specific information should reflect unique job duties, equipment, operating experience, and trainee entry-level qualifications. Revisions to these guidelines should be reviewed for applicability and incorporated into the training program using each utility's training system development (TSD) procedures. Plant-specific job analysis and task analysis data is essential to the development of performance-based training programs. These analyses are particularly useful in selecting tasks for training and in developing on-the-job training (OJT), laboratory training, and mock-up training. Qualification programs based on these

  7. Lageos assembly operation plan

    Science.gov (United States)

    Brueger, J.

    1975-01-01

    Guidelines and constraints procedures for LAGEOS assembly, operation, and design performance are given. Special attention was given to thermal, optical, and dynamic analysis and testing. The operation procedures illustrate the interrelation and sequence of tasks in a flow diagram. The diagram also includes quality assurance functions for verification of operation tasks.

  8. Process control guidelines for CY 70 thorium campaign

    International Nuclear Information System (INIS)

    Jackson, R.R.

    1970-01-01

    The report comprises five parts, with part I being an introduction. Part II consists of a general treatment of process control methods. Parts III through V discuss, in the flowsheet sequence, those problems pertinent to each equipment piece or system and provide operating guidelines. Specific operations that are somewhat different from those normally encountered in Purex are discussed at length. Operations routine to Purex can be found in the pertinent standard operating procedures. Part VI describes in general terms the sequence to be followed in initiating and completing a variety of transient conditions

  9. Treatment of Cushing's Syndrome: An Endocrine Society Clinical Practice Guideline

    Science.gov (United States)

    Nieman, Lynnette K.; Biller, Beverly M. K.; Findling, James W.; Murad, M. Hassan; Newell-Price, John; Savage, Martin O.; Tabarin, Antoine

    2015-01-01

    Objective: The objective is to formulate clinical practice guidelines for treating Cushing's syndrome. Participants: Participants include an Endocrine Society-appointed Task Force of experts, a methodologist, and a medical writer. The European Society for Endocrinology co-sponsored the guideline. Evidence: The Task Force used the Grading of Recommendations, Assessment, Development, and Evaluation system to describe the strength of recommendations and the quality of evidence. The Task Force commissioned three systematic reviews and used the best available evidence from other published systematic reviews and individual studies. Consensus Process: The Task Force achieved consensus through one group meeting, several conference calls, and numerous e-mail communications. Committees and members of The Endocrine Society and the European Society of Endocrinology reviewed and commented on preliminary drafts of these guidelines. Conclusions: Treatment of Cushing's syndrome is essential to reduce mortality and associated comorbidities. Effective treatment includes the normalization of cortisol levels or action. It also includes the normalization of comorbidities via directly treating the cause of Cushing's syndrome and by adjunctive treatments (eg, antihypertensives). Surgical resection of the causal lesion(s) is generally the first-line approach. The choice of second-line treatments, including medication, bilateral adrenalectomy, and radiation therapy (for corticotrope tumors), must be individualized to each patient. PMID:26222757

  10. Montana Curriculum Guidelines for Distributive Education. Revised.

    Science.gov (United States)

    Harris, Ron, Ed.

    These distributive education curriculum guidelines are intended to provide Montana teachers with teaching information for 11 units. Units cover introduction to marketing and distributive education, human relations and communications, operations and control, processes involved in buying for resale, merchandise handling, sales promotion, sales and…

  11. Assessment of EPRI water chemistry guidelines for new nuclear power plants

    International Nuclear Information System (INIS)

    Reid Richard; Kim Karen; McCree, Anisa; Eaker, Richard; Sawochka, Steve; Giannelli, Joe

    2012-09-01

    Water chemistry control technologies for nuclear power plants have been significantly enhanced over the past few decades to improve material and equipment reliability and fuel performance, and to minimize radionuclide production and transport. Chemistry Guidelines have been developed by the Electric Power Research Institute (EPRI) for currently operating plants and have been intermittently revised over the past twenty-five years for the protection of systems and components and for radiation management. As new plants are being designed for improved safety and increased power production, it is important to ensure that the designs consider implementation of state-of-the-art, industry developed water chemistry controls. In parallel, the industry will need to consider and update water chemistry guidelines as well as plant startup and operational strategies based on the advanced plant designs. EPRI has performed assessments of water chemistry control guidance or assumptions provided in design and licensing documents for several advanced plant designs. These designs include: Westinghouse AP1000 Pressurized Water Reactor AREVA US-EPR Pressurized Water Reactor Mitsubishi Nuclear Energy Systems/Mitsubishi Heavy Industries Advanced Pressurized Water Reactor Korea Hydro and Nuclear Power APR1400 Pressurized Water Reactor Toshiba Advanced Boiling Water Reactor (ABWR) General Electric-Hitachi Economic Simplified Boiling Water Reactor (ESBWR) The intent of these assessments was to identify key design differences in each of the new plant designs relative to the current operating fleet and to identify differences in water chemistry specifications or design assumptions provided in design and licensing documents for the plants in comparison to current EPRI Water Chemistry Guidelines. This paper provides a summary of the key results of these assessments. The fundamental design and operation of the advanced plants is similar to the currently operating fleet. As such, the new plants are

  12. Developing clinical practice guidelines: target audiences, identifying topics for guidelines, guideline group composition and functioning and conflicts of interest.

    Science.gov (United States)

    Eccles, Martin P; Grimshaw, Jeremy M; Shekelle, Paul; Schünemann, Holger J; Woolf, Steven

    2012-07-04

    Clinical practice guidelines are one of the foundations of efforts to improve health care. In 1999, we authored a paper about methods to develop guidelines. Since it was published, the methods of guideline development have progressed both in terms of methods and necessary procedures and the context for guideline development has changed with the emergence of guideline clearing houses and large scale guideline production organisations (such as the UK National Institute for Health and Clinical Excellence). It therefore seems timely to, in a series of three articles, update and extend our earlier paper. In this first paper we discuss: the target audience(s) for guidelines and their use of guidelines; identifying topics for guidelines; guideline group composition (including consumer involvement) and the processes by which guideline groups function and the important procedural issue of managing conflicts of interest in guideline development.

  13. Guideline of guidelines: asymptomatic microscopic haematuria.

    Science.gov (United States)

    Linder, Brian J; Bass, Edward J; Mostafid, Hugh; Boorjian, Stephen A

    2018-02-01

    The aim of the present study was to review major organizational guidelines on the evaluation and management of asymptomatic microscopic haematuria (AMH). We reviewed the haematuria guidelines from: the American Urological Association; the consensus statement by the Canadian Urological Association, Canadian Urologic Oncology Group and Bladder Cancer Canada; the American College of Physicians; the Joint Consensus Statement of the Renal Association and British Association of Urological Surgeons; and the National Institute for Health and Care Excellence. All guidelines reviewed recommend evaluation for AMH in the absence of potential benign aetiologies, with the evaluation including cystoscopy and upper urinary tract imaging. Existing guidelines vary in their definition of AMH (role of urine dipstick vs urine microscopy), the age threshold for recommending evaluation, and the optimal imaging method (computed tomography vs ultrasonography). Of the reviewed guidelines, none recommended the use of urine cytology or urine markers during the initial AMH evaluation. Patients should have ongoing follow-up after a negative initial AMH evaluation. Significant variation exists among current guidelines for AMH with respect to who should be evaluated and in what manner. Given the patient and health system implications of balancing appropriately focused and effective diagnostic evaluation, AMH represents a valuable future research opportunity. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.

  14. Autonomous Operations Design Guidelines for Flight Hardware

    Data.gov (United States)

    National Aeronautics and Space Administration — SSC experimentally modified an autonomous operations flexible system suite developed for a ground application for a flight system under development by JSC. The...

  15. The Japanese Society of Pathology Guidelines on the handling of pathological tissue samples for genomic research: Standard operating procedures based on empirical analyses.

    Science.gov (United States)

    Kanai, Yae; Nishihara, Hiroshi; Miyagi, Yohei; Tsuruyama, Tatsuhiro; Taguchi, Kenichi; Katoh, Hiroto; Takeuchi, Tomoyo; Gotoh, Masahiro; Kuramoto, Junko; Arai, Eri; Ojima, Hidenori; Shibuya, Ayako; Yoshida, Teruhiko; Akahane, Toshiaki; Kasajima, Rika; Morita, Kei-Ichi; Inazawa, Johji; Sasaki, Takeshi; Fukayama, Masashi; Oda, Yoshinao

    2018-02-01

    Genome research using appropriately collected pathological tissue samples is expected to yield breakthroughs in the development of biomarkers and identification of therapeutic targets for diseases such as cancers. In this connection, the Japanese Society of Pathology (JSP) has developed "The JSP Guidelines on the Handling of Pathological Tissue Samples for Genomic Research" based on an abundance of data from empirical analyses of tissue samples collected and stored under various conditions. Tissue samples should be collected from appropriate sites within surgically resected specimens, without disturbing the features on which pathological diagnosis is based, while avoiding bleeding or necrotic foci. They should be collected as soon as possible after resection: at the latest within about 3 h of storage at 4°C. Preferably, snap-frozen samples should be stored in liquid nitrogen (about -180°C) until use. When intending to use genomic DNA extracted from formalin-fixed paraffin-embedded tissue, 10% neutral buffered formalin should be used. Insufficient fixation and overfixation must both be avoided. We hope that pathologists, clinicians, clinical laboratory technicians and biobank operators will come to master the handling of pathological tissue samples based on the standard operating procedures in these Guidelines to yield results that will assist in the realization of genomic medicine. © 2018 The Authors. Pathology International published by Japanese Society of Pathology and John Wiley & Sons Australia, Ltd.

  16. EXPLORING BIM FOR OPERATIONAL INTEGRATED ASSET MANAGEMENT – A PRELIMINARY STUDY UTILISING REAL-WORLD INFRASTRUCTURE DATA

    Directory of Open Access Journals (Sweden)

    G. A. Boyes

    2017-10-01

    Full Text Available The use of 3D information models within collaborative working environments and the practice of Building Information Modelling (BIM are becoming more commonplace within infrastructure projects. Currently used predominantly during the design and construction phase, the use of BIM is capable in theory of providing the information at handover that will satisfy the Asset Information Requirements (AIRs of the future Infrastructure Manager (IM. One particular challenge is establishing a link between existing construction-centric information and the asset-centric information needed for future operations. Crossrail, a project to build a new high-frequency railway underneath London, is handling many such challenges as they prepare to handover their digital information to the future operator, in particular the need to provide a two-way link between a federated 3D CAD model and an object-relational Asset Information Management System (AIMS. This paper focusses on the potential for improved Asset Management (AM by integrating BIM and GIS systems and practices, and makes a preliminary report on how 3D spatial queries can be used to establish a two-way relational link between two information systems (3D geometry and asset lists, as well as the challenges being overcome to transform the data to be suitable for AM.

  17. Preliminary Hazards Analysis of K-Basin Fuel Encapsulation and Storage

    International Nuclear Information System (INIS)

    Strickland, G.C.

    1994-01-01

    This Preliminary Hazards Analysis (PHA) systematically examines the K-Basin facilities and their supporting systems for hazards created by abnormal operating conditions and external events (e.g., earthquakes) which have the potential for causing undesirable consequences to the facility worker, the onsite individual, or the public. The operational activities examined are fuel encapsulation, fuel storage and cooling. Encapsulation of sludges in the basins is not examined. A team of individuals from Westinghouse produced a set of Hazards and Operability (HAZOP) tables documenting their examination of abnormal process conditions in the systems and activities examined in K-Basins. The purpose of this report is to reevaluate and update the HAZOP in the original Preliminary Hazard Analysis of K-Basin Fuel Encapsulation and Storage originally developed in 1991

  18. Guidelines for nuclear plant response to an earthquake

    International Nuclear Information System (INIS)

    1989-12-01

    Guidelines have been developed to assist nuclear plant personnel in the preparation of earthquake response procedures for nuclear power plants. The objectives of the earthquake response procedures are to determine (1) the immediate effects of an earthquake on the physical condition of the nuclear power plant, (2) if shutdown of the plant is appropriate based on the observed damage to the plant or because the OBE has been exceeded, and (3) the readiness of the plant to resume operation following shutdown due to an earthquake. Readiness of a nuclear power plant to restart is determined on the basis of visual inspections of nuclear plant equipment and structures, and the successful completion of surveillance tests which demonstrate that the limiting conditions for operation as defined in the plant Technical Specifications are met. The guidelines are based on information obtained from a review of earthquake response procedures from numerous US and foreign nuclear power plants, interviews with nuclear plant operations personnel, and a review of reports of damage to industrial equipment and structures in actual earthquakes. 7 refs., 4 figs., 4 tabs

  19. Development of guidelines to review advanced human-system interfaces

    International Nuclear Information System (INIS)

    O'Hara, J.M.

    1993-01-01

    Advanced control rooms (ACRS) will utilize advanced human-system interface (HSI) technologies that may have significant implications for plant safety in that they will affect the operators overall role in the system, the method of information presentation, and the ways in which operators interact with the system. The US Nuclear Regulatory Commission (NRC) reviews the HSI aspects of control rooms to ensure that they are designed to good human factors engineering principles and that operator performance and reliability are appropriately supported in order to protect public health and safety. The principal guidance available to the NRC, however, was developed more than ten years ago, well prior to these technological changes. Accordingly, the human factors guidance needs to be updated to serve as the basis for NRC review of these advanced designs. The purpose of this paper is to discuss the development, evaluation, and current status of the Advanced HSI Design Review Guideline, hereafter referred to as the ''Guideline.''

  20. BWR Water Chemistry Guidelines: 1993 Revision, Normal and hydrogen water chemistry

    International Nuclear Information System (INIS)

    Karlberg, G.; Goddard, C.; Fitzpatrick, S.

    1994-02-01

    The goal of water chemistry control is to extend the operating life of the reactor and rector coolant system, balance-of-plant components, and turbines while simultaneously controlling costs to safeguard the continued economic viability of the nuclear power generation investment. To further this goal an industry committee of chemistry personnel prepared guidelines to identify the benefits, risks, and costs associated with water chemistry in BWRs and to provide a template for an optimized water chemistry program. This document replaces the BWR Normal Water Chemistry Guidelines - 1986 Revision and the BWR Hydrogen Water Chemistry Guidelines -- 1987 Revision. It expands on the previous guidelines documents by covering the economic implications of BWR water chemistry control

  1. Guidelines for Guidelines: Are They Up to the Task? A Comparative Assessment of Clinical Practice Guideline Development Handbooks

    Science.gov (United States)

    Ansari, Shabnam; Rashidian, Arash

    2012-01-01

    Objectives We conducted a comparative review of clinical practice guideline development handbooks. We aimed to identify the main guideline development tasks, assign weights to the importance of each task using expert opinions and identify the handbooks that provided a comprehensive coverage of the tasks. Methods We systematically searched and included handbooks published (in English language) by national, international or professional bodies responsible for evidenced-based guideline development. We reviewed the handbooks to identify the main guideline development tasks and scored each handbook for each task from 0 (the handbook did not mention the task) to 2 (the task suitably addressed and explained), and calculated a weighted score for each handbook. The tasks included in over 75% of the handbooks were considered as ‘necessary’ tasks. Result Nineteen guideline development handbooks and twenty seven main tasks were identified. The guideline handbooks’ weighted scores ranged from 100 to 220. Four handbooks scored over 80% of the maximum possible score, developed by the National Institute for Health and Clinical Excellence, Swiss Centre for International Health, Scottish Intercollegiate Guidelines Network and World Health Organization. Necessary tasks were: selecting the guideline topic, determining the guideline scope, identifying relevant existing guidelines, involving the consumers, forming guideline development group,, developing clinical questions, systematic search for evidence, selecting relevant evidence, appraising identifies research evidence, making group decision, grading available evidence, creating recommendations, final stakeholder consultation, guideline implementation strategies, updating recommendations and correcting potential errors. Discussion Adequate details for evidence based development of guidelines were still lacking from many handbooks. The tasks relevant to ethical issues and piloting were missing in most handbooks. The findings

  2. European Patient Summary Guideline: Focus on Greece.

    Science.gov (United States)

    Berler, Alexander; Tagaris, Anastassios; Chronaki, Catherine

    2016-01-01

    The European Patient Summary (PS) guideline specifies a minimal dataset of essential and important information for unplanned or emergency care initially defined in the epSOS project with aim to improve patients' safety and quality of Care. The eHealth Network of European Union (EU) Member State (MS) representatives established under Article 14 of the EU directive 2011/24 on patient rights to cross-border healthcare adopted PS guideline in November 2013 and since then the guideline has been part of MS strategic eHealth implementation plans, standardization efforts, and concrete regional, national, European and international projects. This paper reviews implementation efforts for the implementation of an operational patient summary service in Greece drawing on challenges and lessons learned for sustainable standards-based large scale eHealth deployment in Europe and abroad, as well as the reuse of best practices from international standards and integration profiles.

  3. Operant Variability: Procedures and Processes

    Science.gov (United States)

    Machado, Armando; Tonneau, Francois

    2012-01-01

    Barba's (2012) article deftly weaves three main themes in one argument about operant variability. From general theoretical considerations on operant behavior (Catania, 1973), Barba derives methodological guidelines about response differentiation and applies them to the study of operant variability. In the process, he uncovers unnoticed features of…

  4. Preliminary Performance Data on Westinghouse Electronic Power Regulator Operating on J34-WE-32 Turbojet Engine in Altitude Wind Tunnel

    Science.gov (United States)

    Ketchum, James R.; Blivas, Darnold; Pack, George J.

    1950-01-01

    The behavior of the Westinghouse electronic power regulator operating on a J34-WE-32 turbojet engine was investigated in the NACA Lewis altitude wind tunnel at the request of the Bureau of Aeronautics, Department of the Navy. The object of the program was to determine the, steady-state stability and transient characteristics of the engine under control at various altitudes and ram pressure ratios, without afterburning. Recordings of the response of the following parameters to step changes in power lever position throughout the available operating range of the engine were obtained; ram pressure ratio, compressor-discharge pressure, exhaust-nozzle area, engine speed, turbine-outlet temperature, fuel-valve position, jet thrust, air flow, turbine-discharge pressure, fuel flow, throttle position, and boost-pump pressure. Representative preliminary data showing the actual time response of these variables are presented. These data are presented in the form of reproductions of oscillographic traces.

  5. Designing nuclear power plants for improved operation and maintenance

    International Nuclear Information System (INIS)

    1996-09-01

    The purpose of this publication is to compile demonstrated, experience based design guidelines for improving the operability and maintainability of nuclear power plants. The guidelines are for use principally in the design of new nuclear power plants, but should also be useful in upgrading existing designs. The guidelines derive from the experience of operating and maintaining existing nuclear power plants as well as from the design of recent plants. In particular these guidelines are based on and consistent with both the EPRI advanced Light Water Reactor Utility Requirements Document, Volume 1, and the European Utility Requirements for LWR Nuclear Power Plants. 6 refs, 1 fig

  6. Designing nuclear power plants for improved operation and maintenance

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-09-01

    The purpose of this publication is to compile demonstrated, experience based design guidelines for improving the operability and maintainability of nuclear power plants. The guidelines are for use principally in the design of new nuclear power plants, but should also be useful in upgrading existing designs. The guidelines derive from the experience of operating and maintaining existing nuclear power plants as well as from the design of recent plants. In particular these guidelines are based on and consistent with both the EPRI advanced Light Water Reactor Utility Requirements Document, Volume 1, and the European Utility Requirements for LWR Nuclear Power Plants. 6 refs, 1 fig.

  7. Preliminary decommissioning plan of the reactor IPEN-MB01

    International Nuclear Information System (INIS)

    Vivas, Ary de Souza

    2014-01-01

    Around the world, many nuclear plants were built and need to be turned off at a certain time because they are close to their recommended time of use is approximately 50 years. So the IAEA (International Atomic Energy Agency), seeks to guide and recommend a set of guidelines for the conduct of activities of nuclear facilities, with special attention to countries that do not have a framework regulatory Legal that sustain the activities of decommissioning. Brazil, so far, does not have a specific standard to guide the steps of the guidelines regarding decommissioning research reactors. However, in March 2011 a study committee was formed with the main task facing the issues of decommissioning of nuclear installations in Brazil, culminating in Resolution 133 of November 8, 2012, a standard project that treat about the Decommissioning of nucleoelectric plants. O Instituto de Pesquisas Energeticas e Nucleares (IPEN) has two research reactors one being the reactor IPEN/MB-01. The purpose of this master dissertation is to develop a preliminary plan for decommissioning this research reactor, considering the technical documentation of the facility (RAS-Safety Analysis Report), the existing standards of CNEN (National Nuclear Energy Commission), as well as IAEA recommendations. In terms of procedures for decommissioning research reactors, this work was based on what is most modern in experiences, strategies and lessons learned performed and documented in IAEA publications covering techniques and technologies for decommissioning. Considering these technical knowledge and due to the peculiarities of the facility, was selected to immediate dismantling strategy, which corresponds to the start of decommissioning activities once the installation is switched off, dividing it into work sectors. As a resource for monitoring and project management of reactor decommissioning and maintenance of records, we developed a database using Microsoft Access 2007, which contain all the items and

  8. Network operating system

    Science.gov (United States)

    1985-01-01

    Long-term and short-term objectives for the development of a network operating system for the Space Station are stated. The short-term objective is to develop a prototype network operating system for a 100 megabit/second fiber optic data bus. The long-term objective is to establish guidelines for writing a detailed specification for a Space Station network operating system. Major milestones are noted. Information is given in outline form.

  9. Guidelines for Management Information Systems in Canadian Health Care Facilities

    Science.gov (United States)

    Thompson, Larry E.

    1987-01-01

    The MIS Guidelines are a comprehensive set of standards for health care facilities for the recording of staffing, financial, workload, patient care and other management information. The Guidelines enable health care facilities to develop management information systems which identify resources, costs and products to more effectively forecast and control costs and utilize resources to their maximum potential as well as provide improved comparability of operations. The MIS Guidelines were produced by the Management Information Systems (MIS) Project, a cooperative effort of the federal and provincial governments, provincial hospital/health associations, under the authority of the Canadian Federal/Provincial Advisory Committee on Institutional and Medical Services. The Guidelines are currently being implemented on a “test” basis in ten health care facilities across Canada and portions integrated in government reporting as finalized.

  10. Guidelines for evaluation of the environmental expense in the nuclear fuel cycle

    International Nuclear Information System (INIS)

    Komatsu, Cintia Nagako

    2008-01-01

    The main objective of this research is to establish guidelines to fit the environment account in the nuclear fuel cycle, using as study of case the uranium hexafluoride production unit of Centro Tecnologico da Marinha in Sao Paulo. The environment accounting, branch of the accounting science, supply a source of tools capable to measure the protection efforts, the nature preservation, the environment monitoring and the recovering during all the conversion phase (since the uranium concentrated, the yellow cake, up to the Uranium hexafluoride production). It was performed several researches, visits to the Centre, databank creation, interviews and extensive consulting to the preliminary safety report, in order to obtain the percentage of the total expenses related to environment protection in regarding to the total amount invested in the unit. It was also evaluated the total preserved green area making possible a preliminary environment accounting balance. (author)

  11. Cost analysis guidelines

    International Nuclear Information System (INIS)

    Strait, R.S.

    1996-01-01

    The first phase of the Depleted Uranium Hexafluoride Management Program (Program)--management strategy selection--consists of several program elements: Technology Assessment, Engineering Analysis, Cost Analysis, and preparation of an Environmental Impact Statement (EIS). Cost Analysis will estimate the life-cycle costs associated with each of the long-term management strategy alternatives for depleted uranium hexafluoride (UF6). The scope of Cost Analysis will include all major expenditures, from the planning and design stages through decontamination and decommissioning. The costs will be estimated at a scoping or preconceptual design level and are intended to assist decision makers in comparing alternatives for further consideration. They will not be absolute costs or bid-document costs. The purpose of the Cost Analysis Guidelines is to establish a consistent approach to analyzing of cost alternatives for managing Department of Energy's (DOE's) stocks of depleted uranium hexafluoride (DUF6). The component modules that make up the DUF6 management program differ substantially in operational maintenance, process-options, requirements for R and D, equipment, facilities, regulatory compliance, (O and M), and operations risk. To facilitate a consistent and equitable comparison of costs, the guidelines offer common definitions, assumptions or basis, and limitations integrated with a standard approach to the analysis. Further, the goal is to evaluate total net life-cycle costs and display them in a way that gives DOE the capability to evaluate a variety of overall DUF6 management strategies, including commercial potential. The cost estimates reflect the preconceptual level of the designs. They will be appropriate for distinguishing among management strategies

  12. PWR secondary water chemistry guidelines: Revision 3

    International Nuclear Information System (INIS)

    Lurie, S.; Bucci, G.; Johnson, L.; King, M.; Lamanna, L.; Morgan, E.; Bates, J.; Burns, R.; Eaker, R.; Ward, G.; Linnenbom, V.; Millet, P.; Paine, J.P.; Wood, C.J.; Gatten, T.; Meatheany, D.; Seager, J.; Thompson, R.; Brobst, G.; Connor, W.; Lewis, G.; Shirmer, R.; Gillen, J.; Kerns, M.; Jones, V.; Lappegaard, S.; Sawochka, S.; Smith, F.; Spires, D.; Pagan, S.; Gardner, J.; Polidoroff, T.; Lambert, S.; Dahl, B.; Hundley, F.; Miller, B.; Andersson, P.; Briden, D.; Fellers, B.; Harvey, S.; Polchow, J.; Rootham, M.; Fredrichs, T.; Flint, W.

    1993-05-01

    An effective, state-of-the art secondary water chemistry control program is essential to maximize the availability and operating life of major PWR components. Furthermore, the costs related to maintaining secondary water chemistry will likely be less than the repair or replacement of steam generators or large turbine rotors, with resulting outages taken into account. The revised PWR secondary water chemistry guidelines in this report represent the latest field and laboratory data on steam generator corrosion phenomena. This document supersedes Interim PWR Secondary Water Chemistry Recommendations for IGA/SCC Control (EPRI report TR-101230) as well as PWR Secondary Water Chemistry Guidelines--Revision 2 (NP-6239)

  13. A preliminary framework for corporate real estate sustainable management

    Directory of Open Access Journals (Sweden)

    Fauzi Nurul Sahida

    2016-01-01

    Full Text Available The global warming issue has motivated corporations to go green in their business operations including transforming from conventional real estate to green features real estate. However green CRE is more complex to manage due to a building’s significant impact on environmental, social and economic aspects. Thus the need to have a best practice guide or framework as reference is crucial. Unfortunately, no best practice guidelines on CRE management have been found to be sufficient as much uncertainty still exists on the sustainable performance measurement components. This research aims to explore and then summarize the present sustainable CREM practices and components relating to sustainable performance measurement integrating a sustainable theory that balances environmental, economic and social impacts. These act as indicators to measure the outcomes of the practice in the form of a generic model on sustainability preliminary framework for CRESM. The objectives of this research include identifying corporate real estate sustainable management (CRESM practice and components of sustainable performance measurement. The research uses content analysis method to analyse data gathered from literature and previous studies. The findings will be demonstrated in the form of a framework model on CRESM that will include14 CREM strategies and 15 components derived from analysis.

  14. Prognostic Predictors of Outcome in an Operative Series in Traumatic Brain Injury Patients

    Directory of Open Access Journals (Sweden)

    Jinn-Rung Kuo

    2011-04-01

    Conclusion: In our preliminary findings, five variables to predict poor outcomes 6 months after TBI were useful. These sensitive variables can be used as a referential guideline in our daily practice to decide whether or not to perform advanced management or avoid decompressive craniectomy.

  15. Draft revision of human factors guideline HF-010

    International Nuclear Information System (INIS)

    Lee, Hyun Chul; Lee, Yong Hee; Oh, In Seok; Lee, Jung Woon; Cha, Woo Chang; Lee, Dhong Ha

    2003-05-01

    The Application of Human Factors to the design of Man-Machine Interfaces System(MMIS) in the nuclear power plant is essential to the safety and productivity of the nuclear power plants, human factors standards and guidelines as well as human factors analysis methods and experiments are weightily used to the design application. A Korean engineering company has developed a human factors engineering guideline, so-call HF-010, and has used it for human factors design, however the revision of HF-010 is necessary owing to lack of the contents related to the advanced MMI(Man-Machine Interfaces). As the results of the reviews of HF-010, it is found out that the revision of Section 9. Computer Displays of HF-010 is urgent, thus the revision was drafted on the basis of integrated human factors design guidelines for VDT, human factors design guidelines for PMAS SPADES display, human factors design guidelines for PMAS alarm display, and human factors design guidelines for electronic displays developed by the surveillance and operation support project of KOICS. The draft revision of HF-010 Section 9 proposed in this report can be utilized for the human factors design of the advanced MMI, and the high practical usability of the draft can be kept up through the continuous revision according to the advancement of digital technology

  16. Formalization of treatment guidelines using Fuzzy Cognitive Maps and semantic web tools.

    Science.gov (United States)

    Papageorgiou, Elpiniki I; Roo, Jos De; Huszka, Csaba; Colaert, Dirk

    2012-02-01

    Therapy decision making and support in medicine deals with uncertainty and needs to take into account the patient's clinical parameters, the context of illness and the medical knowledge of the physician and guidelines to recommend a treatment therapy. This research study is focused on the formalization of medical knowledge using a cognitive process, called Fuzzy Cognitive Maps (FCMs) and semantic web approach. The FCM technique is capable of dealing with situations including uncertain descriptions using similar procedure such as human reasoning does. Thus, it was selected for the case of modeling and knowledge integration of clinical practice guidelines. The semantic web tools were established to implement the FCM approach. The knowledge base was constructed from the clinical guidelines as the form of if-then fuzzy rules. These fuzzy rules were transferred to FCM modeling technique and, through the semantic web tools, the whole formalization was accomplished. The problem of urinary tract infection (UTI) in adult community was examined for the proposed approach. Forty-seven clinical concepts and eight therapy concepts were identified for the antibiotic treatment therapy problem of UTIs. A preliminary pilot-evaluation study with 55 patient cases showed interesting findings; 91% of the antibiotic treatments proposed by the implemented approach were in fully agreement with the guidelines and physicians' opinions. The results have shown that the suggested approach formalizes medical knowledge efficiently and gives a front-end decision on antibiotics' suggestion for cystitis. Concluding, modeling medical knowledge/therapeutic guidelines using cognitive methods and web semantic tools is both reliable and useful. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Preliminary I&C Design for LORELEI

    International Nuclear Information System (INIS)

    Korotkin, S.; Kaufman, Y.; Guttmann, E. B.; Levy, S.; Amidan, D.; Gdalyho, B.; Cahana, T.; Ellenbogen, A.; Arad, M.; Weiss, Y.; Sasson, A.; Ferry, L.; Bourrelly, F.; Cohen, Y.

    2014-01-01

    This document summarizes the preliminary I&C design for LORELEI experiment The preliminary design deals with considerations regarding appropriate safety and service instrumentation. The determined closed loop control rules for temperature and position will be implemented in the detailed design. The Computer Aided Operator Decisions System (CAODS) will be used for prediction of hot spot temperature and thickness of oxidation layer using Baker-Just correlation. The proposed hybrid simulation system comprising of both virtual and real hardware will be in-cooperated for LORELEI verification. It will perform both integration cold tests for a partial hardware loop and virtual tests for the final I&C design

  18. [Formulation of guidelines for microscopic endodontics suitable for the situation of China].

    Science.gov (United States)

    Ling, J Q

    2016-08-01

    In order to promote the use of dental operating microscope in endodontics, Society of Cariology and Endodontology of Chinese Stomatological Association formulated these guidelines, after extensive consultation with related authorities and careful reference to the available published materials and literatures. It is hoped that these guidelines will be useful for dental practitioners embarking on microscopic endodontics.

  19. Guidelines for wireless technology in nuclear power plants

    International Nuclear Information System (INIS)

    Shankar, Ramesh

    2003-01-01

    As a result of technological breakthroughs, increased demand for the use of wireless technology is common in all industries today, and the electric power industry is no exception. Already, wireless technology has many applications in our industry, including - but not limited to - cellular phone systems, paging systems, two-way radio communication systems, dose management and tracking systems, and operator logs. EPRI has prepared a comprehensive guidelines document to support evaluation of wireless technologies in power plants for integrated (voice/data/video) communication, remote equipment and system monitoring, and to complement an electronic procedures support system (EPSS). The guidelines effort focuses on the development of a rules structure to support the deployment of wireless devices in a plant without compromising continuous, safe, and reliable operation. The guidelines document consists of two volumes. The first volume is introductory in nature and lays out the business case for applying wireless technologies. The intended audience is senior plant management personnel and utility industry executives. This volume contains background information, templates, worksheets, processes, and presentations that will allow internal sponsors to create business cases for piloting wireless projects. The second volume includes guidance on implementation and regulatory issues relevant to plant implementation. It covers the following application areas: implementation of integrated communication capability, equipment monitoring, work quality control, time and knowledge management, and business process automation. It details regulatory issues relevant to the adoption of wireless technology within nuclear power plants and offers guidance on preparing for and executing pilot and implementations of wireless technologies. The paper will cover important aspects on the guidelines. (author)

  20. Radioactive waste shredding: Preliminary evaluation

    International Nuclear Information System (INIS)

    Soelberg, N.R.; Reimann, G.A.

    1994-07-01

    The critical constraints for sizing solid radioactive and mixed wastes for subsequent thermal treatment were identified via a literature review and a survey of shredding equipment vendors. The types and amounts of DOE radioactive wastes that will require treatment to reduce the waste volume, destroy hazardous organics, or immobilize radionuclides and/or hazardous metals were considered. The preliminary steps of waste receipt, inspection, and separation were included because many potential waste treatment technologies have limits on feedstream chemical content, physical composition, and particle size. Most treatment processes and shredding operations require at least some degree of feed material characterization. Preliminary cost estimates show that pretreatment costs per unit of waste can be high and can vary significantly, depending on the processing rate and desired output particle size

  1. Plans to adapt Point Lepreau ageing management to new industry guidelines

    International Nuclear Information System (INIS)

    Greenlaw, G.; Gendron, T.; Slade, J.; Rankin, B.

    2008-01-01

    In preparation for PLGS life extension, NBPN spent considerable effort to evaluate the impact of ageing and to develop ageing management processes to maintain the required safety functions for extended operation. These were based on INPO AP-913. Recently, the CNSC has been developing Canadian ageing management guidelines in line with the IAEA approach. In response, NBPN plans to document how current PLGS processes meet the new CNSC guidelines and to identify any areas for improvement. Best practices from utilities that have retrofitted IAEA guidelines and PLGS experience in applying risk-based methods for ageing management will be used to implement improvements. (author)

  2. 33 CFR 127.315 - Preliminary transfer inspection.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) WATERFRONT FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS Waterfront Facilities Handling Liquefied Natural Gas Operations § 127.315 Preliminary transfer... parts; (b) For each of the vessel's cargo tanks from which cargo will be transferred, note the pressure...

  3. Guidelines for developing effective health education service in a national health agency.

    Science.gov (United States)

    Ochor, J O

    1983-01-01

    The constraints facing health education include: the fragmentation and dispersal of health-educational services among different agencies and personnel; lack of policy guidelines; ineffectively organized and inefficiently managed health education systems; poor hierarchical status and inadequacy of resources. To resolve these constraints, national health education systems in health agencies should be developed on the basis of stipulated guidelines that could ensure their viability, efficiency and effectiveness. A study at the African Regional Health Education Centre, Ibadan, Nigeria, has yielded thirty synthesized guidelines. The "guidelines" were empirically tested as an evaluation tool by assessing the operational and organizational status of Oyo State Health Education Unit, Ibadan, Nigeria. These guidelines are adaptable to local conditions to enhance the re-organization, re-orientation and consolidation of health education in national health agencies.

  4. NSPWG-recommended safety requirements and guidelines for SEI nuclear propulsion

    International Nuclear Information System (INIS)

    Marshall, A.C.; Lee, J.H.; McCulloch, W.H.; Sawyer, J.C. Jr.; Bari, R.A.; Brown, N.W.; Cullingford, H.S.; Hardy, A.C.; Remp, K.; Sholtis, J.A.

    1992-01-01

    An Interagency Nuclear Safety Policy Working Group (NSPWG) was chartered to recommend nuclear safety policy, requirements, and guidelines for the Space Exploration Initiative (SEI) nuclear propulsion program to facilitate the implementation of mission planning and conceptual design studies. The NSPWG developed a top- level policy to provide the guiding principles for the development and implementation of the nuclear propulsion safety program and the development of Safety Functional Requirements. In addition the NSPWG reviewed safety issues for nuclear propulsion and recommended top-level safety requirements and guidelines to address these issues. Safety requirements were developed for reactor start-up, inadvertent criticality, radiological release and exposure, disposal, entry, and safeguards. Guidelines were recommended for risk/reliability, operational safety, flight trajectory and mission abort, space debris and meteoroids, and ground test safety. In this paper the specific requirements and guidelines will be discussed

  5. Guidelines for Inter-Enterprise Management (IEM), GLOBEMEN Deliverable D23

    DEFF Research Database (Denmark)

    Tølle, Martin; Vesterager, Johan

    2002-01-01

    This document is a deliverable of Work package 2 of the IMS Globemen (GMN) project: D23 Guidelines for Inter-Enterprise Management (IEM). IMS Globemen is an inter-regional project aiming to develop methods, tools and architectures to support inter-enterprise operations in one-of-kind industries......-Project, the developed solution for Inter-Enterprise Management. The structure of the deliverable is as follows: - Chapter 1 introduces the guidelines and outlines the structure of the deliverable - Chapter 2 defines key terms along with a list of acronyms used in the deliverable - Chapter 3 gives a general introduction...... for inter-enterprise management (IEM). - Chapter 5 contains the actual Guidelines The chapter contains guidelines for how to prepare enterprise network in being able to set up and manage virtual enterprises. The section consists of a set of activities an enterprise should/could consider when preparing...

  6. Fatigue assessments in operating nuclear power plants

    International Nuclear Information System (INIS)

    Gosselin, S.R.; Deardorff, A.F.; Peltola, D.W.

    1994-01-01

    In November 1991, the ASME Section XI Task Group on Operating Plant Fatigue Assessment was formed to develop criteria and evaluation methodology for evaluating the effects of cyclic operation in operating nuclear power plants. The objective was to develop guidelines for inclusion in Section XI that could be used by plant operators in evaluating fatigue concerns and their impact on serviceability. This paper discusses the work performed by the Task Group. It explores the concept of ''Fatigue Design Basis'' versus ''Fatigue Operating Basis'' by examining the roles of ASME Section III and ASME Section XI in the design and operation of the nuclear power plants. Guidelines are summarized that may help plant operators perform effective design transient cycle evaluations and optimize cycle counting and fatigue usage tracking. The alternative fatigue evaluation approach using flaw tolerance is also introduced

  7. Health requirements for nuclear reactor operators

    International Nuclear Information System (INIS)

    1980-05-01

    The health prerequisites established for the qualification of nuclear reactor operators according to CNEN-NE-1.01 Guidelines Licensing of nuclear reactor operators, CNEN-12/79 Resolution, are described. (M.A.) [pt

  8. Do guidelines influence results in inguinal hernia treatment? A descriptive study of 2,535 hernia repairs in one teaching hospital from 1994 to 2004

    NARCIS (Netherlands)

    Aufenacker, T. J.; Schmits, S. P.; Gouma, D. J.; Simons, M. P.

    2009-01-01

    BACKGROUND: The Onze Lieve Vrouwe Gasthuis (OLVG) hospital is a large district teaching hospital with a residency programme for general surgery. Since 1998, inguinal hernia (IH) repairs in this hospital were performed according to the preliminary "evidence-based guidelines" concerning IH repair. The

  9. Guideline on in-service testing (IST) of ECCS for nuclear power stations in Japan

    International Nuclear Information System (INIS)

    Yamashita, N.; Honjin, M.; Yamazaki, M.; Iwami, H.

    2001-01-01

    In Japan, METI (Ministry of Economy, Trade and Industry) periodic inspections are conducted every 13 months in accordance with the EUIL (Electric Utility Industry Law) for light water reactors. On the other hand, during operation, many kinds of function tests are conducted in accordance with Technical Specifications or utilities voluntary test procedures. However, these maintenance activities during outages are in other respects considered too costly and more than necessary because of its predetermined maintenance interval and its old-fashioned full scope maintenance menu. In these circumstances, the ASME O and M Codes and Standards, which are applied to nuclear power plants in the United States, came to be one of the issues to be considered among Japanese utilities. This is because the ASME O and M Codes and Standards, which are developed to verify the operational readiness of equipment or systems by condition based maintenance or performance testing without overhauls, will be considered to suggest a rational alternative to our existing maintenance activities. Because there had been no standard for function tests other than the METI inspection procedures in Japan, activities started for the development of Japanese Operation and Maintenance Guideline (hereinafter called the Japanese OM Guideline or the Guideline) for function tests and condition monitoring. The Japanese OM Guideline is not proclaimed for regulatory use, but the long-term objective is to provide a substantial basis to change the current maintenance activities including regulatory inspection. The Guideline is composed of five parts, which are general requirements, pumps, valves, snubbers and ECCS systems. This paper gives a summary of the ECCS part of the Japanese OM Guideline, in particular, focusing on the differences between the Guideline and the ASME O and M Standards, and topics or discussion during their establishment. (author)

  10. Development of a preliminary decommissioning plan of the reactor IPEN/MB-01

    International Nuclear Information System (INIS)

    Vivas, Ary de Souza; Carneiro, Alvaro Luiz Guimaraes

    2013-01-01

    Around the world, many nuclear plants were built and need to be turned off at a certain time because they are close to their recommended time of use is approximately 50 years. So the IAEA (International Atomic Energy Agency), seeks to guide and recommend, through publications, guidelines for the conduct of activities both for decommissioning nuclear power plants and for research reactors, with special attention to countries that do not have a framework regulatory Legal that sustain the activities of decommissioning. Brazil, so far, does not have a specific standard to guide the steps of the guidelines regarding decommissioning research reactors, having only a standard applied to decommissioning power plants which was published in November 2012. The Nuclear and Energy Research Institute (IPEN) has two research reactors one being the reactor IPEN/MB-01. The aim of this work is to develop a preliminary plan for decommissioning of nuclear reactor research, considering the technical documentation of the system (RAS-Safety Analysis Report), the existing rules of CNEN (National Nuclear Energy Commission), as well as regulatory instructions and recommendations of the IAEA. The preliminary decommissioning plan consists of the presentation of actions and steps required as well as the strategies to be adopted for the shutdown of the facility under the technical and administrative, seeking the safety, health workers and the general public, minimizing environmental impacts. (author)

  11. The emergency response guidelines for the Westinghouse pressurized water reactor

    International Nuclear Information System (INIS)

    Dekens, J.P.; Bastien, R.; Prokopovich, S.R.

    1985-01-01

    The Three Mile Island accident has demonstrated that the guidance provided for mitigating the consequences of design basis accidents could be inadequate when multiple incidents, failures or errors occur during or after the accident. Westinghouse and the Westinghouse Owners Group have developed new Emergency Response Guidelines (E.R.G.). The E.R.G. are composed of two independent sets of procedures and of a systematic tool to continuously evaluate the plant safety throughout the response to an accident. a) The Optimal Recovery Guidelines are entered each time the reactor is tripped or the Emergency Core Cooling System is actuated. An immediate verification of the automatic protective actuations is performed and the accident diagnosis process is initiated. When nature of the accident is identified, the operator is transferred to the applicable recovery procedure and subprocedures. A permanent rediagnosis is performed throughout the application of the optimal Recovery Guidelines and cross connections are provided to the adequate procedure if an error in diagnosis is identified. b) Early in the course of the accident, the operating staff initiates monitoring of the Critical Safety Functions. These are defined as the set of functions ensuring the integrity of the physical barriers against radioactivity release. The review of these functions is peformed continuously through a cyclic application of the status trees. c) The Function Restoration Guidelines are entered when the Critical Safety Function monitoring identifies a challenge to one of the functions. Depending on the severity of the challenge, the transfer to a Function Restoration Guideline can be immediate for a severe challenge or delayed for a minor challenge. Those guidelines are independent of the scenario of the accident, but only based on plant parameters and equipment availability

  12. 33 CFR 127.1315 - Preliminary transfer inspection.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) WATERFRONT FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS Waterfront Facilities Handling Liquefied Hazardous Gas Operations § 127.1315 Preliminary... capacity of each storage tank to or from which LHG will be transferred, to ensure that it is safe for...

  13. Siting guidelines and their role in repository site selection

    International Nuclear Information System (INIS)

    Hanlon, C.L.

    1985-01-01

    The first requirement of the Nuclear Waste Policy Act was for the Secretary of Energy to issue general guidelines for siting repositories. The guidelines were to specify detailed geologic considerations that would be the primary criteria for the selection of sites in various host rocks, as well as factors that would qualify or disqualify any site from development as a repository. These guidelines were clearly intended to provide not only the framework for the siting program but also the stimulus for establishing effective communication and consultation among the parties involved in the program. The Act further required that the guidelines be a factor in the development of all future decision documents of the Office of Civilian Radioactive Waste Management, including the environmental assessments that would accompany the nomination of sites for characterization, the site-characterization plans that are to be prepared before the sinking of exploratory shafts at any candidate site, and the environmental impact statement that is to support the recommendation of a site for development as a repository. More than two years after its passage, the intention of the Act for the guidelines has been realized. Concurred in by the Nuclear Regulatory Commission on June 22, 1984, and issued by the Department in November 1984, the guidelines include postclosure technical guidelines that apply to conditions governing the long-term performance of the repository system; preclosure technical guidelines that apply to conditions governing the siting, construction, operation, and closure of the repository; and system guidelines whose objective is to ensure that the regulatory requirements of the Environmental Protection Agency and the Nuclear Regulatory Commission are met

  14. Operation of the OSIRIS reactor from the viewpoint of analysis of operator functions

    International Nuclear Information System (INIS)

    Fichet-Clairfontaine, P.Y.; Saint-Jean, T.

    1985-09-01

    This paper presents the results of analyses carried out on site by the Human Factor Study Laboratory in an experimental nuclear plant operated by the Atomic Energy Commissariat - the OSIRIS pool reactor. The analyses of certain tasks are given: work in the reactor hall and an operation of circuit setting performed by the mechanics. This work has thrown light on certain operational guidelines implemented by the operators when carrying out their work [fr

  15. National Synchrotron Light Source guidelines for the conduct of operations

    International Nuclear Information System (INIS)

    Fewell, N.

    1990-03-01

    This report briefly discusses the following topics: NSLS operations organization and administration; shift routines and operating practices; NSLS control room activities; communications; control of on-shift training; investigation of abnormal events; notifications; control of equipment and system status; lock-out tagout; independent verification; logkeeping; shift turnover; required reading; shift orders; equipment operations guides; operator aid postings; and equipment labeling

  16. Nuclear criticality safety training: guidelines for DOE contractors

    International Nuclear Information System (INIS)

    Crowell, M.R.

    1983-09-01

    The DOE Order 5480.1A, Chapter V, Safety of Nuclear Facilities, establishes safety procedures and requirements for DOE nuclear facilities. This guide has been developed as an aid to implementing the Chapter V requirements pertaining to nuclear criticality safety training. The guide outlines relevant conceptual knowledge and demonstrated good practices in job performance. It addresses training program operations requirements in the areas of employee evaluations, employee training records, training program evaluations, and training program records. It also suggests appropriate feedback mechanisms for criticality safety training program improvement. The emphasis is on academic rather than hands-on training. This allows a decoupling of these guidelines from specific facilities. It would be unrealistic to dictate a universal program of training because of the wide variation of operations, levels of experience, and work environments among DOE contractors and facilities. Hence, these guidelines do not address the actual implementation of a nuclear criticality safety training program, but rather they outline the general characteristics that should be included

  17. Comments from the Behavioral Teratology Committee of the Japanese Teratology Society on OECD guideline for the testing of chemicals, proposal for a new guideline 426, developmental neurotoxicity study, draft document (September 2003).

    Science.gov (United States)

    Fukui, Yoshihiro; Ema, Makoto; Fujiwara, Michio; Higuchi, Hashihiro; Inouye, Minoru; Iwase, Takayuki; Kihara, Takahide; Nishimura, Tatsuya; Oi, Akihide; Ooshima, Yojiro; Otani, Hiroki; Shinomiya, Mitsuhiro; Sugioka, Kozo; Yamano, Tsunekazu; Yamashita, Keisuke H; Tanimura, Takashi

    2004-09-01

    In September 2003, a new revision of the draft guideline (Organization for Economic Co-operation and Development [OECD] Guideline for the Testing of Chemicals, Proposal for a New Guideline 426, Developmental Neurotoxicity Study) was distributed. The draft guideline consists of 51 paragraphs and an appendix. The National Coordinators were requested to arrange national expert reviews of the guideline proposal in their member countries. The member of the Behavioral Teratology (BT) Committee of the Japanese Teratology Society (JTS) reviewed, discussed and commented on the draft Test Guideline proposal. The BT Committee of the JTS also commented that the International Collaborative Study to validate this protocol should be definitely performed. These comments were sent to the OECD Secretariat. The BT Committee of the JTS expects that the comments are useful for further discussion.

  18. Operational limits and disruptions in ITER

    Energy Technology Data Exchange (ETDEWEB)

    Tsunematsu, T; Mizoguchi, T; Yoshino, R [Japan Atomic Energy Research Inst., Tokyo (Japan); Borrass, K; Engelmann, F; Pacher, G; Pacher, H [Max-Planck-Institut fuer Plasmaphysik, Garching (Germany, F.R.). NET Design Team; Cohen, S; Post, D [Princeton Univ., NJ (USA). Plasma Physics Lab.; Hogan, J; Uckan, N A [Oak Ridge National Lab., TN (USA); Krasheninnikov, S; Mukhovatov, V; Parail, V

    1990-12-15

    Detailed knowledge of the operational limits for beta, q and the plasma density will be required for successful and flexible operation of ITER. In this paper, the present data base and guidelines on operational limits and disruptions in the ITER design are presented. 10 refs., 1 fig.

  19. Small Wind Site Assessment Guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, Tim [Advanced Energy Systems LLC, Eugene, OR (United States); Preus, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-09-01

    Site assessment for small wind energy systems is one of the key factors in the successful installation, operation, and performance of a small wind turbine. A proper site assessment is a difficult process that includes wind resource assessment and the evaluation of site characteristics. These guidelines address many of the relevant parts of a site assessment with an emphasis on wind resource assessment, using methods other than on-site data collection and creating a small wind site assessment report.

  20. NOS CO-OPS Water Level Data, Preliminary, 6-Minute

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset has recent, preliminary (not quality-controlled), 6-minute, water level (tide) data from NOAA NOS Center for Operational Oceanographic Products and...

  1. NOS CO-OPS Water Level Data, Preliminary, 1-Minute

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset has recent, preliminary (not quality-controlled), 1-minute, water level (tide) data from NOAA NOS Center for Operational Oceanographic Products and...

  2. An evaluation of safety guidelines to restrict exposure to stray radiofrequency radiation from short-wave diathermy units

    Energy Technology Data Exchange (ETDEWEB)

    Shields, Nora [School of Physiotherapy, La Trobe University, Victoria 3086 (Australia); O' Hare, Neil [Department of Medical Physics and Bioengineering, St James' s Hospital, Dublin 8 (Ireland); Gormley, John [School of Physiotherapy, Trinity College Dublin, Trinity Centre for Health Sciences, St James' s Hospital, Dublin 8 (Ireland)

    2004-07-07

    Short-wave diathermy (SWD), a form of radiofrequency radiation used therapeutically by physiotherapists, may be applied in continuous (CSWD) or pulsed (PSWD) mode using either capacitive or inductive methods. Stray radiation emitted by these units may exceed exposure guidelines close to the equipment. Discrepant guidelines exist on a safe distance from an operating unit for operators and other personnel. Stray electric (E-field) and magnetic (H-field) field strengths from 10 SWD units in six departments were examined using a PMM 8053 meter and two isotropic probes (EP-330, HP-032). A 5 l saline phantom completed the patient circuit. Measurements were recorded in eight directions between 0.5 m and 2 m at hip and eye levels while the units operated at maximum output and data compared to current guidelines. Results found stray fields from capacitive CSWD fell below operator limits at 2 m (E-field 4.8-39.8 V/m; H-field 0.015-0.072 A/m) and at 1 m for inductive CSWD (E-field 0-36 V/m; H-field 0.01-0.065 A/m). Capacitive PSWD fields fell below the limits at 1.5 m (E-field 1.2-19.9 V/m; H-field 0.002-0.045 A/m) and at 1m for inductive PSWD (E-field 0.7-4.0 V/m; H-field 0.009-0.03 A/m). An extra 0.5 m was required before fields fell below the guidelines for other personnel. These results demonstrate, under a worst case scenario, emissions from SWD exceed the guidelines for operators at distances currently recommended as safe. Future guidelines should include recommendations for personnel other than physiotherapists.

  3. An evaluation of safety guidelines to restrict exposure to stray radiofrequency radiation from short-wave diathermy units

    International Nuclear Information System (INIS)

    Shields, Nora; O'Hare, Neil; Gormley, John

    2004-01-01

    Short-wave diathermy (SWD), a form of radiofrequency radiation used therapeutically by physiotherapists, may be applied in continuous (CSWD) or pulsed (PSWD) mode using either capacitive or inductive methods. Stray radiation emitted by these units may exceed exposure guidelines close to the equipment. Discrepant guidelines exist on a safe distance from an operating unit for operators and other personnel. Stray electric (E-field) and magnetic (H-field) field strengths from 10 SWD units in six departments were examined using a PMM 8053 meter and two isotropic probes (EP-330, HP-032). A 5 l saline phantom completed the patient circuit. Measurements were recorded in eight directions between 0.5 m and 2 m at hip and eye levels while the units operated at maximum output and data compared to current guidelines. Results found stray fields from capacitive CSWD fell below operator limits at 2 m (E-field 4.8-39.8 V/m; H-field 0.015-0.072 A/m) and at 1 m for inductive CSWD (E-field 0-36 V/m; H-field 0.01-0.065 A/m). Capacitive PSWD fields fell below the limits at 1.5 m (E-field 1.2-19.9 V/m; H-field 0.002-0.045 A/m) and at 1m for inductive PSWD (E-field 0.7-4.0 V/m; H-field 0.009-0.03 A/m). An extra 0.5 m was required before fields fell below the guidelines for other personnel. These results demonstrate, under a worst case scenario, emissions from SWD exceed the guidelines for operators at distances currently recommended as safe. Future guidelines should include recommendations for personnel other than physiotherapists

  4. The need for operating guidelines and a decision making framework applicable to the discovery of non-intelligent extraterrestrial life

    Science.gov (United States)

    Race, Margaret S.; Randolph, Richard O.

    While formal principles have been adopted for the eventuality of detecting intelligent life in our galaxy (SETI Principles), no such guidelines exist for the discovery of non-intelligent extraterrestrial life within the solar system. Current scientifically based planetary protection policies for solar system exploration address how to undertake exploration, but do not provide clear guidance on what to do if and when life is detected. Considering that martian life could be detected under several different robotic and human exploration scenarios in the coming decades, it is appropriate to anticipate how detection of non-intelligent, microbial life could impact future exploration missions and activities, especially on Mars. This paper discusses a proposed set of interim guidelines based loosely on the SETI Principles and addresses issues extending from the time of discovery through future handling and treatment of extraterrestrial life on Mars or elsewhere. Based on an analysis of both scientific and ethical considerations, there is a clear need for developing operating protocols applicable at the time of discovery and a decision making framework that anticipates future missions and activities, both robotic and human. There is growing scientific confidence that the discovery of extraterrestrial life in some form is nearly inevitable. If and when life is discovered beyond Earth, non-scientific dimensions may strongly influence decisions about the nature and scope of future missions and activities. It is appropriate to encourage international discussion and consideration of the issues prior to an event of such historical significance.

  5. Measure Guideline: Window Repair, Rehabilitation, and Replacement

    Energy Technology Data Exchange (ETDEWEB)

    Baker, P.

    2012-12-01

    This measure guideline provides information and guidance on rehabilitating, retrofitting, and replacing existing window assemblies in residential construction. The intent is to provide information regarding means and methods to improve the energy and comfort performance of existing wood window assemblies in a way that takes into consideration component durability, in-service operation, and long term performance of the strategies.

  6. Development of comprehensive HFE guidelines for the evaluation of NPP human systems interfaces

    International Nuclear Information System (INIS)

    O'Hara, J.M.; Brown, W.S.; Wachtel, J.

    1994-01-01

    Advanced control room (ACR) concepts are being developed in the commercial nuclear power industry as part of future reactor designs. The ACRs will use advanced human-system interface (HSI) technologies that may have significant implications for plant safety in that they will affect the ways in which the operator interacts with and supervises an increasingly complex system. The US Nuclear Regulatory Commission (NRC) reviews the HSI aspects of control rooms to ensure that they are designed to good human factors engineering principles and that operator performance and reliability are appropriately supported to protect public health and safety. The NRC is developing guidelines to support its review of these advanced designs. This paper discusses (1) the development of guidelines for advanced HSI review, (2) the integration of those guidelines with existing guidance, and (3) a methodology for further guidance development

  7. 40 CFR 417.162 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Detergents Subcategory § 417.162 Effluent limitations guidelines... available (BPT): (a) For normal liquid detergent operations the following values pertain: Effluent...

  8. Active subspaces for the optimal meanline design of unconventional turbomachinery

    NARCIS (Netherlands)

    Bahamonde Noriega, Juan S.; Pini, M.; de Servi, C.M.; Colonna di Paliano, Piero

    2017-01-01

    The preliminary fluid dynamic design of turbomachinery operating with non-standard working fluids and unusual operating conditions and specifications can be very challenging because of the lack of know-how and guidelines. Examples are the design of turbomachinery for small-capacity organic

  9. Preliminary design report: Prototypical Spent Fuel Consolidation Equipment Demonstration Project: Phase 1

    International Nuclear Information System (INIS)

    Blissell, W.H.; Ciez, A.P.; Mitchell, J.L.; Winkler, C.J.

    1986-12-01

    This document describes the Westinghouse Preliminary Design for the Prototypical Consolidation Demonstration Project per Department of Energy (DOE) Contract No. DE-AC07-86ID12649 and under direction of the DOE Idaho Operations Office. The preliminary design is the first step to providing the Department of Energy with a fully qualified, licensable, cost-effective spent fuel rod consolidation system. The design was developed using proven technologies and equipment to create an innovative approach to previous rod consolidation concepts. These innovations will better enable the Westinghouse system to: consolidate fuel rods in a precise, fully-controlled, accountable manner; package all rods from two PWR fuel assemblies or from four BWR fuel assemblies in one 8.5 inch square consolidated rods canister; meet all functional requirements; operate with all fuel types common to the US commercial nuclear industry with minimal tooling changeouts; and meet consolidation production process rates, while maintaining operator and public health and safety. This Preliminary Design Report provides both detailed descriptions of the equipment required to perform the rod consolidation process and the supporting analyses to validate the design

  10. NICE guidelines for imaging studies in children with UTI adequate only in boys under the age of 6 months.

    Science.gov (United States)

    Ristola, Marko Tapani; Hurme, Timo

    2013-03-01

    The purpose of this study was to evaluate the applicability of the National Institute for Health and Clinical Excellence (NICE) guidelines for imaging studies in children under the age of three with first urinary tract infection (UTI). In our cohort of 112 patients, we gathered data regarding the occurrence of indications for ultrasonography (US) and voiding cystourethrography (VCUG) according to the NICE guidelines, dimercaptosuccinic acid (DMSA) scintigraphy examinations, UTI recurrence, antimicrobial prophylaxis (AMP), anti-reflux procedures, and other urological procedures. If the NICE guidelines had been applied, 13 of the 25 patients (52 %) with vesicoureteral reflux (VUR), including 6 of the 12 patients (50 %) with dilating VUR and 3 of the 4 patients who underwent endoscopic anti-reflux treatment, would have been missed, and a negative VCUG would have been avoided in 25 of the 42 patients (60 %) with no VUR. None of the missed diagnoses occurred in the younger boys' group. Based on these preliminary analyses, we feel that the NICE guidelines for imaging studies in children under 3 years old with UTI may be applicable to clinical use only in boys under 6 months of age. For other patients the guidelines were unsuccessful.

  11. Flexible guideline-based patient careflow systems.

    Science.gov (United States)

    Quaglini, S; Stefanelli, M; Lanzola, G; Caporusso, V; Panzarasa, S

    2001-04-01

    Workflow Management Systems integrate domain and organisational knowledge to support business processes. When applied to the medical environment, they can be termed "Careflow Management Systems", and may be used to manage care delivery by enhancing co-operation among healthcare professionals. This paper focuses on care delivery based on clinical practice guidelines. Healthcare organisations are very different from industrial or commercial companies: their main goal is not profit, but maintaining and improving the health of the public. Therefore, outcomes are difficult to measure. Firstly, physicians, while playing a variety of roles, are quite independent decision-makers; secondly, the object of the process, i.e. the patient, may be involved in choosing treatment options, and may be treated by different institutions. For these reasons, the standard functionality of typical Workflow Management Systems must be strongly enhanced in order to cope with healthcare delivery needs. A major issue is accounting for exceptions. In most non-clinical settings this is not a problem because processes are very well defined and can often be easily controlled by some higher authority. As explained above, this does not happen in healthcare organisations. Responsibilities are widely shared, and health care professionals may be non-compliant with guidelines for a variety of reasons. The paper presents a classification of possible exceptions, and shows how the sequence of tasks described by a guideline may be altered, at the implementation level, in order to meet actual user needs, while maintaining guideline intentions as much as possible. A terminology server is also exploited towards this end. This work illustrates a prototype of a Careflow Management System based on an international guideline for ischemic stroke treatment, developed by the American Heart Association.

  12. Harvesting forest biomass for energy in Minnesota: An assessment of guidelines, costs and logistics

    Science.gov (United States)

    Saleh, Dalia El Sayed Abbas Mohamed

    The emerging market for renewable energy in Minnesota has generated a growing interest in utilizing more forest biomass for energy. However, this growing interest is paralleled with limited knowledge of the environmental impacts and cost effectiveness of utilizing this resource. To address environmental and economic viability concerns, this dissertation has addressed three areas related to biomass harvest: First, existing biomass harvesting guidelines and sustainability considerations are examined. Second, the potential contribution of biomass energy production to reduce the costs of hazardous fuel reduction treatments in these trials is assessed. Third, the logistics of biomass production trials are analyzed. Findings show that: (1) Existing forest related guidelines are not sufficient to allow large-scale production of biomass energy from forest residue sustainably. Biomass energy guidelines need to be based on scientific assessments of how repeated and large scale biomass production is going to affect soil, water and habitat values, in an integrated and individual manner over time. Furthermore, such guidelines would need to recommend production logistics (planning, implementation, and coordination of operations) necessary for a potential supply with the least site and environmental impacts. (2) The costs of biomass production trials were assessed and compared with conventional treatment costs. In these trials, conventional mechanical treatment costs were lower than biomass energy production costs less income from biomass sale. However, a sensitivity analysis indicated that costs reductions are possible under certain site, prescriptions and distance conditions. (3) Semi-structured interviews with forest machine operators indicate that existing fuel reduction prescriptions need to be more realistic in making recommendations that can overcome operational barriers (technical and physical) and planning and coordination concerns (guidelines and communications

  13. Spanish guideline for the definition and assessment of risk-informed inservice inspection programs for piping

    International Nuclear Information System (INIS)

    Figueras, J.M.; Olivar, F.; Mendoza, C.; Vazquez, T.; Morales, L.; Bros, J.; Mach, I.; Gutierrez, E.

    2001-01-01

    The recent emphasis on risk-informed in-service inspection has been taken on by the Spanish Utilities and the Spanish Regulatory Body in their proposal for a co-operation project for defining a Risk-Informed In-Service Inspection Guideline for Piping. This paper describes first the main features of this Spanish guideline and then the results of the pilot applications developed in order to check the consistency of the guideline. (authors)

  14. Spanish guideline for the definition and assessment of risk-informed inservice inspection programs for piping

    Energy Technology Data Exchange (ETDEWEB)

    Figueras, J.M.; Olivar, F.; Mendoza, C.; Vazquez, T. [CSN, Madrid (Spain); Morales, L. [UNESA, Madrid (Spain); Bros, J.; Mach, I. [Tecnatom, Madrid (Spain); Gutierrez, E. [Iberinco, Madrid (Spain)

    2001-07-01

    The recent emphasis on risk-informed in-service inspection has been taken on by the Spanish Utilities and the Spanish Regulatory Body in their proposal for a co-operation project for defining a Risk-Informed In-Service Inspection Guideline for Piping. This paper describes first the main features of this Spanish guideline and then the results of the pilot applications developed in order to check the consistency of the guideline. (authors)

  15. Preliminary safety analysis methodology for the SMART

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Kyoo Hwan; Chung, Y. J.; Kim, H. C.; Sim, S. K.; Lee, W. J.; Chung, B. D.; Song, J. H. [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2000-03-01

    This technical report was prepared for a preliminary safety analysis methodology of the 330MWt SMART (System-integrated Modular Advanced ReacTor) which has been developed by Korea Atomic Energy Research Institute (KAERI) and funded by the Ministry of Science and Technology (MOST) since July 1996. This preliminary safety analysis methodology has been used to identify an envelope for the safety of the SMART conceptual design. As the SMART design evolves, further validated final safety analysis methodology will be developed. Current licensing safety analysis methodology of the Westinghouse and KSNPP PWRs operating and under development in Korea as well as the Russian licensing safety analysis methodology for the integral reactors have been reviewed and compared to develop the preliminary SMART safety analysis methodology. SMART design characteristics and safety systems have been reviewed against licensing practices of the PWRs operating or KNGR (Korean Next Generation Reactor) under construction in Korea. Detailed safety analysis methodology has been developed for the potential SMART limiting events of main steam line break, main feedwater pipe break, loss of reactor coolant flow, CEA withdrawal, primary to secondary pipe break and the small break loss of coolant accident. SMART preliminary safety analysis methodology will be further developed and validated in parallel with the safety analysis codes as the SMART design further evolves. Validated safety analysis methodology will be submitted to MOST as a Topical Report for a review of the SMART licensing safety analysis methodology. Thus, it is recommended for the nuclear regulatory authority to establish regulatory guides and criteria for the integral reactor. 22 refs., 18 figs., 16 tabs. (Author)

  16. Revised DTI Guidelines for Petroleum Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, D.; Philip, L.N.

    1997-07-01

    The DTI's guidelines on petroleum measurement have been extensively revised and enlarged. The new guidelines cover a much wider scope of measurement situations than before. Included in the new issue is guidance on allocation measurement, well testing, multiphase flow measurement, new technology acceptance procedures and operating procedures for different types of measurement systems. Significant changes have taken place in recent years both in the way the oil and gas industry conducts its business and in the fiscal regime operated by the UK government. New developments in flow measurement have progressed to such an extent that they have now been adopted by the industry or are close to being adopted as beneficial methods of the measurement of hydrocarbons in whatever form they present themselves for measurement. The rapid pace of development has left the standards-making bodies behind and in some cases there is insufficient quality data to enable the standards makers to produce guidance of the generic type appropriate for national or international standards. The case-by-case approach of the DTI in approving methods of measurement lends itself better to consideration of new technology where there may be no existing standards. These, amongst other considerations, make it appropriate for the DTI to extend the scope of its guidance into these new areas. The policy developments behind the changes in the new guidelines are not static and this new document has been produced in response to an evolutionary process which is still continuing but it is right to collate and make defining statements from time to time to put on record the current status of measurement requirements for the purpose of attaining DTI approval. (author)

  17. Development of on-line operator aid system (OASYSTM) for nuclear power plants

    International Nuclear Information System (INIS)

    Kang, Ki Sig; Choi, Seong Soo; Kim, Han Gon; Chang, Soon Heung; Jeong, Hee Kyo; Yi, Chul Un

    1994-01-01

    In this paper, the development of On - line operator Aid SYStem (OASYS TM ) are discussed by focusing attention on the importance of the operator's role for nuclear power plants. The OASYS TM is under development to support the operator's decision making process and to enhance the safety of a nuclear power plant by providing the plant operators with timely and proper guideline during abnormal and emergency conditions. The OASYS TM has capabilities for the signal validation/management, the alarm processing, the failure diagnosis using abnormal operating procedures, and the dynamic tracking of emergency operating procedures using function restoration guidelines and optimal recovery guidelines with a series of complex logic steps covering a broad spectrum of event sequences. The proposed system is being implemented on a SUN-4/75 Workstation using C and Quintus TM prolog language. For verification studies a full-scope real-time simulator is being used. Test results show that the OASYS TM is capable of diagnosing a plant failure quickly and providing an operator guideline with fast response time. After verification the OASYS TM will be installed in the simulator II of Kori nuclear training center

  18. FALCON Code Simulation for Verification of Fuel Preconditioning Guideline

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hee-Hun; Kwon, Oh-Hyun; Kim, Hong-Jin; Kim, Yong-Hwan [KEPCO Nuclear Fuel Co. Ltd., Daejeon (Korea, Republic of)

    2015-10-15

    The magnitude and rate of power increases are key factors in the PCI failure process. KEPCO NF (KNF) provides operational restrictions called fuel preconditioning guideline (FPG) to mitigate PCI failures. The FPG contains recommended power maneuvering restrictions that should be followed when the KNF supplied fuel is being operated in-reactor. This guideline typically includes controlled power ramp rates, threshold power levels to initiate controlled ramp rates, and restrictions on the operating conditions that impact the potential for PCI failure. The purpose of the FPG is to allow time for stress relaxation to reduce cladding stress buildup during power maneuvers. Two general approaches have been adopted in the development of FPG to mitigate PCI failure in operating commercial reactors. The first approach relies primarily on past operational experience and power ramp test. The second one uses an analytical methodology where a figure-of-merit representative of PCI vulnerability, generally cladding hoop stress, is calculated using a fuel performance code. FALCON simulation can be the identification of a PCI limit parameter, typically cladding hoop stress, which can be used to evaluate a power maneuvering restriction on FPG. The PCI analysis is to assess the cladding hoop stress under various power ramp conditions. Startup ramp rate doesn't affect PCI failure until 50% of rated thermal power.

  19. [Guidelines for management of epilepsy--commentary on Scottish ("SIGN") guidelines].

    Science.gov (United States)

    Planjar-Prvan, Miljenka; Granić, Davorka

    2005-01-01

    The choice of AED (antiepileptic drug), worldwide and in Croatia, is been still based on the physician's subjective decision, personal experience, knowledge and marketing pressure made by big pharmaceutical industries. Therefore, according to some opinions, there is a need of treatment guidelines for epilepsy that would provide relevant information based on scientific evidence on the efficacy, tolerability and safety of AEDs. The guidelines, published by a competent source, should be designed as to allow for easy access to the information on the best practice in specific cases. An extensive background literature review was made to identify such a type of guidelines for the management of epilepsy. The literature review revealed a number of references with the recommendations for treating epilepsy in different groups of patients and from various, specific aspects of epilepsy treatment. However, only one comprehensive set of guidelines for the diagnosis and treatment of epilepsy treatment was found, i.e. the evidence-based guidelines published by the Scottish Intercollegiate Guidelines Network (SIGN). The development of this set of guidelines is quite extensively described in order to illustrate how rigorous and long-lasting the process was, including a great number of health professionals at the national level. Such a type of well designed guidelines facilitates access to highest educational standards for all professionals involved in the primary and secondary care of people with epilepsy. However, it is clear that guidelines can fully replace the standards of clinical practice based on critical evaluation and integration of all clinical data of each individual patient. No guidelines can replace the physician's obligation to keep informed of the novel achievements in the epileptology either.

  20. The development of oncology treatment guidelines: an analysis of the National Guidelines Clearinghouse.

    Science.gov (United States)

    Palta, Manisha; Lee, W Robert

    2011-01-01

    In the last 2 decades, guidelines have been developed to improve quality of patient care. A recent editorial of guideline development procedures suggested the process has significant limitations that affect their scientific validity.(1) This prompted us to review oncology treatment guidelines to determine if such limitations are widespread. We performed a review of oncology treatment guidelines registered at the National Guidelines Clearinghouse (www.guideline.gov). Each guideline was independently reviewed by 2 authors and the following criteria were assessed: coordinating organization, guideline panel composition, reporting conflict of interest, peer review, dissent, expiration date, PubMed citation, and evidence-based scoring and grading of recommendations. Disagreements were resolved by consensus in subsequent discussions. Sixty-four guidelines were reviewed (39 [61%] were developed by a medical specialty society and 25 [39%] were developed by government agencies). Fifty (78%) guideline panels were multidisciplinary and 44 (69%) included individuals with epidemiologic and health services research expertise. Potential conflicts of interest were disclosed in 43 (67%) guidelines. Sixty (94%) guidelines underwent peer review, with external review in 31 (48%). Seventeen (27%) guidelines are indexed by PubMed. Fifty-one (80%) guidelines included evidence-based methodologies and 46 (72%) used evidence-based scoring of recommendations. Significant differences were observed according to coordinating organization (eg, disclosure of conflict of interest in 46% of guidelines developed by medical specialty societies versus 100% authored by government agencies [P <.0001]). The majority of oncology-related treatment guidelines registered at the National Guidelines Clearinghouse satisfy most of the criteria for sound guideline development. Significant differences in these criteria were observed according to the coordinating organization that developed the guideline. Copyright

  1. Experimental study on display-control stereotype and development of human factors guidelines

    International Nuclear Information System (INIS)

    Lee, Jung Woon; Lee, Yong Hee; Oh, In Seok; Lee, Hyun Chul; Cha, Woo Chang

    2003-01-01

    It is very important to develop the design guidelines which can be applicable for Korean operators for the purpose of designing the KSNP more safely. The objective of this project is to provide the standards, guidelines and bases applicable for HF-010 through the within-subject experiment for obtaining Korean operators' population stereotype for direction-of-movement of controls associated with displays on the control panels. Through the survey of researches on display compatibility and the classification of types of displays and controls in the main control room of Uljin units 3 and 4, methods for an experiment on the stereotype were established. Experimental interface prototypes for a total of 108 combinations of display and control types were implemented. Experimental data collection and analysis system was built in association with the interface prototypes. The experiment was performed with participation of 250 students as subjects. About 20 guideline items were developed based on the results obtained from our analysis of experimental data

  2. Experimental study on display-control stereotype and development of human factors guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Woon; Lee, Yong Hee; Oh, In Seok; Lee, Hyun Chul [KAERI, Taejon (Korea, Republic of); Cha, Woo Chang [Kumoh National Univ. of Technolgy, Gumi (Korea, Republic of)

    2003-01-01

    It is very important to develop the design guidelines which can be applicable for Korean operators for the purpose of designing the KSNP more safely. The objective of this project is to provide the standards, guidelines and bases applicable for HF-010 through the within-subject experiment for obtaining Korean operators' population stereotype for direction-of-movement of controls associated with displays on the control panels. Through the survey of researches on display compatibility and the classification of types of displays and controls in the main control room of Uljin units 3 and 4, methods for an experiment on the stereotype were established. Experimental interface prototypes for a total of 108 combinations of display and control types were implemented. Experimental data collection and analysis system was built in association with the interface prototypes. The experiment was performed with participation of 250 students as subjects. About 20 guideline items were developed based on the results obtained from our analysis of experimental data.

  3. 78 FR 277 - Section 610 Review of NPDES Permit Regulation and Effluent Limitations Guidelines Standards for...

    Science.gov (United States)

    2013-01-03

    ..., Section 610 Review of NPDES Permit Regulation and Effluent Limitations Guidelines Standards for..., FRL-9764-8] Section 610 Review of NPDES Permit Regulation and Effluent Limitations Guidelines Standards for Concentrated Animal Feeding Operations (CAFOs); Extension of Comment Period AGENCY...

  4. Recommendations to the NRC on human engineering guidelines for nuclear power plant maintainability

    Energy Technology Data Exchange (ETDEWEB)

    Badalamente, R.V.; Fecht, B.A.; Blahnik, D.E.; Eklund, J.D.; Hartley, C.S.

    1986-03-01

    This document contains human engineering guidelines which can enhance the maintainability of nuclear power plants. The guidelines have been derived from general human engineering design principles, criteria, and data. The guidelines may be applied to existing plants as well as to plants under construction. They apply to nuclear power plant systems, equipment and facilities, as well as to maintenance tools and equipment. The guidelines are grouped into seven categories: accessibility and workspace, physical environment, loads and forces, maintenance facilities, maintenance tools and equipment, operating equipment design, and information needs. Each chapter of the document details specific maintainability problems encountered at nuclear power plants, the safety impact of these problems, and the specific maintainability design guidelines whose application can serve to avoid these problems in new or existing plants.

  5. Recommendations to the NRC on human engineering guidelines for nuclear power plant maintainability

    International Nuclear Information System (INIS)

    Badalamente, R.V.; Fecht, B.A.; Blahnik, D.E.; Eklund, J.D.; Hartley, C.S.

    1986-03-01

    This document contains human engineering guidelines which can enhance the maintainability of nuclear power plants. The guidelines have been derived from general human engineering design principles, criteria, and data. The guidelines may be applied to existing plants as well as to plants under construction. They apply to nuclear power plant systems, equipment and facilities, as well as to maintenance tools and equipment. The guidelines are grouped into seven categories: accessibility and workspace, physical environment, loads and forces, maintenance facilities, maintenance tools and equipment, operating equipment design, and information needs. Each chapter of the document details specific maintainability problems encountered at nuclear power plants, the safety impact of these problems, and the specific maintainability design guidelines whose application can serve to avoid these problems in new or existing plants

  6. Guidelines for indoor air hygiene in school buildings

    Energy Technology Data Exchange (ETDEWEB)

    Moriske, Heinz-Joern; Szewzyk, Regine (eds.)

    2008-08-15

    The new guidelines for indoor air hygiene in school buildings are intended as a response to current requirements in school practice. The recommendations aim to help to avoid mistakes in modernising school buildings and to provide hygiene-specific support in planning of new school buildings. The guidelines are laid out as follows: (a) In the general section the targets of the guidelines and the target groups are addressed. The current indoor hygiene situation in German schools is described, followed by the parameters with regard to peripheral issues which will not be dealt with further; (b) Part A deals with the hygiene requirements in the practical running of schools. Besides general requirements for maintenance and operation the important issues of cleaning and ventilation are considered, as well as minor building works; (c) Part B provides an overview of important chemical and biological contaminants in schools; (d) Part C looks at building and air conditioning requirements. The important issues of acoustic requirements is also addressed; (e) Part D shows how to deal practically with problem cases and list case studies with 'typical' procedures; (f) Part E provides a brief overview of existing renovation guidelines.

  7. Guidelines for indoor air hygiene in school buildings

    Energy Technology Data Exchange (ETDEWEB)

    Moriske, Heinz-Joern; Szewzyk, Regine [eds.

    2008-08-15

    The new guidelines for indoor air hygiene in school buildings are intended as a response to current requirements in school practice. The recommendations aim to help to avoid mistakes in modernising school buildings and to provide hygiene-specific support in planning of new school buildings. The guidelines are laid out as follows: (a) In the general section the targets of the guidelines and the target groups are addressed. The current indoor hygiene situation in German schools is described, followed by the parameters with regard to peripheral issues which will not be dealt with further; (b) Part A deals with the hygiene requirements in the practical running of schools. Besides general requirements for maintenance and operation the important issues of cleaning and ventilation are considered, as well as minor building works; (c) Part B provides an overview of important chemical and biological contaminants in schools; (d) Part C looks at building and air conditioning requirements. The important issues of acoustic requirements is also addressed; (e) Part D shows how to deal practically with problem cases and list case studies with 'typical' procedures; (f) Part E provides a brief overview of existing renovation guidelines.

  8. Advanced human-system interface design review guidelines

    International Nuclear Information System (INIS)

    O'Hara, J.M.

    1990-01-01

    Advanced, computer-based, human-system interface designs are emerging in nuclear power plant control rooms as a result of several factors. These include: (1) incorporation of new systems such as safety parameter display systems, (2) backfitting of current control rooms with new technologies when existing hardware is no longer supported by equipment vendors, and (3) development of advanced control room concepts. Control rooms of the future will be developed almost exclusively with advanced instrumentation and controls based upon digital technology. In addition, the control room operator will be interfacing with more intelligent systems which will be capable of providing information processing support to the operator. These developments may have significant implications for plant safety in that they will greatly affect the operator's role in the system as well as the ways in which he interacts with it. At present, however, the only guidance available to the Nuclear Regulatory Commission (NRC) for the review of control room-operator interfaces is NUREG-0700. It is a document which was written prior to these technological changes and is, therefore, tailored to the technologies used in traditional control rooms. Thus, the present guidance needs to be updated since it is inadequate to serve as the basis for NRC staff review of such advanced or hybrid control room designs. The objective of the project reported in this paper is to develop an Advanced Control Room Design Review Guideline suitable for use in performing human factors reviews of advanced operator interfaces. This guideline will take the form of a portable, interactive, computer-based document that may be conveniently used by an inspector in the field, as well as a text-based document

  9. Hydrothermal Liquefaction Treatment Preliminary Hazard Analysis Report

    Energy Technology Data Exchange (ETDEWEB)

    Lowry, Peter P.; Wagner, Katie A.

    2015-08-31

    A preliminary hazard assessment was completed during February 2015 to evaluate the conceptual design of the modular hydrothermal liquefaction treatment system. The hazard assessment was performed in 2 stages. An initial assessment utilizing Hazard Identification and Preliminary Hazards Analysis (PHA) techniques identified areas with significant or unique hazards (process safety-related hazards) that fall outside of the normal operating envelope of PNNL and warranted additional analysis. The subsequent assessment was based on a qualitative What-If analysis. This analysis was augmented, as necessary, by additional quantitative analysis for scenarios involving a release of hazardous material or energy with the potential for affecting the public.

  10. A preliminary conceptual design study for Korean fusion DEMO reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Keeman, E-mail: kkeeman@nfri.re.kr [National Fusion Research Institute, 169-148 Gwahak-ro, Daejeon 305-806 (Korea, Republic of); Kim, Hyoung Chan; Oh, Sangjun; Lee, Young Seok; Yeom, Jun Ho; Im, Kihak; Lee, Gyung-Su [National Fusion Research Institute, 169-148 Gwahak-ro, Daejeon 305-806 (Korea, Republic of); Neilson, George; Kessel, Charles; Brown, Thomas; Titus, Peter [Princeton Plasma Physics Laboratory, Princeton University, Princeton, NJ 08543 (United States)

    2013-10-15

    Highlights: ► Perform a preliminary conceptual study for a steady-state Korean DEMO reactor. ► Present design guidelines and requirements of Korean DEMO reactor. ► Present a preliminary design of TF (toroidal field) and CS (central solenoid) magnet. ► Present a preliminary result of the radial build scheme of Korean DEMO reactor. -- Abstract: As the ITER is being constructed, there is a growing anticipation for an earlier realization of fusion energy, so called fast-track approach. Korean strategy for fusion energy can be regarded as a fast-track approach and one special concept discussed in this paper is a two-stage development plan. At first, a steady-state Korean DEMO Reactor (K-DEMO) is designed not only to demonstrate a net electricity generation and a self-sustained tritium cycle, but also to be used as a component test facility. Then, at its second stage, a major upgrade is carried out by replacing in-vessel components in order to show a net electric generation on the order of 300 MWe and the competitiveness in cost of electricity (COE). The major radius is designed to be just below 6.5 m, considering practical engineering feasibilities. By using high performance Nb{sub 3}Sn-based superconducting cable currently available, high magnetic field at the plasma center above 8 T can be achieved. A design concept for TF magnets and radial builds for the K-DEMO considering a vertical maintenance scheme, are presented together with preliminary design parameters.

  11. Air quality model guideline

    International Nuclear Information System (INIS)

    Idriss, A.; Spurrell, F.

    2009-06-01

    Alberta Environment has developed a guidelines for operations and proposed operations that require approvals under the province's Environmental Protection and Enhancement Act or that operate under a code of practice for emissions to the atmosphere. In an effort to ensure consistency in the use of dispersion models for regulatory applications in Alberta, this document provided detailed guidance on suitable methods and approaches that should be employed to assess air quality from emission sources, specifically, information required to demonstrate that a source meets the Alberta ambient air quality objectives. The document outlined the statutory authority and provided an overview of the approach. It provided detailed advice on the types and uses of dispersion models with particular reference to the modelling protocol, input data, and output interpretation. Guidance on the application of regulatory models were also presented. Various models were described and their intended uses were explained. Internet addresses for different modelling resources were also offered. Last, some information about regional modelling in the province of Alberta was discussed. 40 refs., 4 tabs., 7 figs., 3 appendices.

  12. ASSET guidelines

    International Nuclear Information System (INIS)

    1990-11-01

    The IAEA Assessment of Safety Significant Events Team (ASSET) Service provides advice and assistance to Member States to enhance the overall level of plant safety while dealing with the policy of prevention of incidents at nuclear power plants. The ASSET programme, initiated in 1986, is not restricted to any particular group of Member States, whether developing or industrialized, but is available to all countries with nuclear power plants in operation or approaching commercial operation. The IAEA Safety Series publications form common basis for the ASSET reviews, including the Nuclear Safety Standards (NUSS) and the Basic Safety Principles (Recommendations of Safety Series No. 75-INSAG-3). The ASSET Guidelines provide overall guidance for the experts to ensure the consistency and comprehensiveness of their review of incident investigations. Additional guidance and reference material is provided by the IAEA to complement the expertise of the ASSET members. ASSET reviews accept different approaches that contribute to ensuring an effective prevention of incidents at plants. Suggestions are offered to enhance plant safety performance. Commendable good practices are identified and generic lessons are communicated to other plants, where relevant, for long term improvement

  13. Versator divertor experiment: preliminary designs

    International Nuclear Information System (INIS)

    Wan, A.S.; Yang, T.F.

    1984-08-01

    The emergence of magnetic divertors as an impurity control and ash removal mechanism for future tokamak reactors bring on the need for further experimental verification of the divertor merits and their ability to operate at reactor relevant conditions, such as with auxiliary heating. This paper presents preliminary designs of a bundle and a poloidal divertor for Versator II, which can operate in conjunction with the existing 150 kW of LHRF heating or LH current drive. The bundle divertor option also features a new divertor configuration which should improve the engineering and physics results of the DITE experiment. Further design optimization in both physics and engineering designs are currently under way

  14. Preliminary Study on Non-Fatal Occupational Injury among Operational Workers in Malaysia Palm Oil Mill

    Directory of Open Access Journals (Sweden)

    Ruslan Rumaizah

    2017-01-01

    Full Text Available Non-fatal occupational injury had becoming major global concern and its consequences to safety and health would be heavily burdening. The aim of this preliminary study was to investigate the distribution of non-fatal occupational injury among specific group of workers in palm oil mill and to acknowledge potential factors of injury causation. A questionnaire survey was designed to assess injury involvement during the employment period among operational workers of palm oil mill located in Southern Peninsular Malaysia. Thirty three (n= 33 workers volunteered and completed the questionnaire. Prevalence of injury among palm oil mill workers was 39.4% with sprain and burn were the common types of injury reported. Press Plant workers reported to have high cases of injuries. Majority of workers (78.8% stated noise was the main hazard in the palm oil mill, followed by heat hazard. Press Plant was identified as one of the specific risk group in palm oil mill based on the rate of injury occurrences reported by the workers. Exposure to noise hazard was estimated to be one of the potential factors of injury causation and further study should be made to measure the risk of hazard.

  15. REVIEW Of COMPUTERIZED PROCEDURE GUIDELINES FOR NUCLEAR POWER PLANT CONTROL ROOMS

    Energy Technology Data Exchange (ETDEWEB)

    David I Gertman; Katya Le Blanc; Ronald L Boring

    2011-09-01

    Computerized procedures (CPs) are recognized as an emerging alternative to paper-based procedures for supporting control room operators in nuclear power plants undergoing life extension and in the concept of operations for advanced reactor designs. CPs potentially reduce operator workload, yield increases in efficiency, and provide for greater resilience. Yet, CPs may also adversely impact human and plant performance if not designed and implemented properly. Therefore, it is important to ensure that existing guidance is sufficient to provide for proper implementation and monitoring of CPs. In this paper, human performance issues were identified based on a review of the behavioral science literature, research on computerized procedures in nuclear and other industries, and a review of industry experience with CPs. The review of human performance issues led to the identification of a number of technical gaps in available guidance sources. To address some of the gaps, we developed 13 supplemental guidelines to support design and safety. This paper presents these guidelines and the case for further research.

  16. Postoperative Pain Management after Carpal Tunnel Syndrome Surgical Treatment: Comparing Practice with Guidelines.

    Science.gov (United States)

    Utrobičić, Ivan; Utrobičić, Frane; Prološčić, Ivona; Utrobičić, Toni; Jerić, Milka; Jeličić Kadić, Antonia; Puljak, Livia

    2017-09-01

    The management of postoperative pain after carpal tunnel syndrome surgical treatment at a tertiary hospital was analyzed and compared with the guidelines for perioperative pain management. This retrospective study included 579 patients operated on for carpal tunnel syndrome at the Split University Hospital Center in Split, Croatia. The following key data were collected from patient medical records: age, gender, type and dosage of premedication, type and dosage of anesthesia, type and dosage of postoperative analgesia per each postoperative day. The procedures related to perioperative pain were analyzed and compared with the current guidelines for perioperative acute pain management. Study results showed that 99.6% of patients with carpal tunnel syndrome were operated under local anesthesia, of which 2.9% also received sedation. Analgesics were prescribed to 45% of patients after surgery, and according to patient charts, 39% of patients actually received postoperative analgesic(s). Generally, postoperative pain was treated on the fi rst postoperative day, mostly with nonsteroidal anti-inflammatory drugs. Only two patients received weak opioids for postoperative pain. Many recommendations from the guidelines for perioperative acute pain management were not followed. In conclusion, the guidelines should be followed and appropriate interventions used to improve postoperative pain management.

  17. Guidelines for prediction of CO{sub 2} corrosion in oil and gas production systems

    Energy Technology Data Exchange (ETDEWEB)

    Nyborg, Rolf

    2009-09-15

    A group of corrosion experts from different oil companies has prepared guidelines for use of CO{sub 2} corrosion prediction tools. The guidelines are intended for use in design and engineering practice applied by companies operating oil and gas production facilities. This document attempts to set minimum guidelines that should be common to most companies. The document is sufficiently flexible to allow individual companies to adapt the information set forth in this document to their own environment and requirements. A methodology for defining the Iikelihood of corrosion and the impact on CO{sub 2} prediction is developed. The CO{sub 2} prediction is based on existing tools. An overview of available CO{sub 2} corrosion prediction models evaluated by the participants is given. It is the responsibility of the operator to select which model to use. (Author)

  18. ITC Guidelines on Quality Control in Scoring, Test Analysis, and Reporting of Test Scores

    Science.gov (United States)

    Allalouf, Avi

    2014-01-01

    The Quality Control (QC) Guidelines are intended to increase the efficiency, precision, and accuracy of the scoring, analysis, and reporting process of testing. The QC Guidelines focus on large-scale testing operations where multiple forms of tests are created for use on set dates. However, they may also be used for a wide variety of other testing…

  19. Guidelines for preparing criticality safety evaluations at Department of Energy non-reactor nuclear facilities

    International Nuclear Information System (INIS)

    1993-11-01

    This document contains guidelines that should be followed when preparing Criticality Safety Evaluations that will be used to demonstrate the safety of operations performed at DOE non-reactor nuclear facilities. Adherence to these guidelines will provide consistency and uniformity in criticality safety evaluations (CSEs) across the complex and will document compliance with the requirements of DOE Order 5480.24

  20. Guidelines for Description

    NARCIS (Netherlands)

    Links, P.; Horsman, Peter; Kühnel, Karsten; Priddy, M.; Reijnhoudt, Linda; Merenmies, Mark

    2013-01-01

    The Guidelines follow the conceptual metadata model (deliverable 17.2). They include guidelines for description of collection-holding institutions, document collections, organisations, personalities, events, camps and ghettos. As much as possible the guidelines comply with the descriptive standards

  1. Preliminary project of installation for separation tubes tests-ITTS

    International Nuclear Information System (INIS)

    Rocha, Z.

    1984-01-01

    A consolidation of actual ideas about installation, entitled ''Installation to separation tubes tests-ITTS'', expected to CDTN is presented. The project bases, the testing to be realized, the procedures to be obeyed during the operation, the components and the space required by installation and auxiliary equipments, the presumable origin of components (nacional and international), including a preliminary list of building and operation costs are described. (author) [pt

  2. Scoliosis Research Society (SRS) Criteria and Society of Scoliosis Orthopaedic and Rehabilitation Treatment (SOSORT) 2008 Guidelines in Non-Operative Treatment of Idiopathic Scoliosis.

    Science.gov (United States)

    Korbel, Krzysztof; Kozinoga, Mateusz; Stoliński, Łukasz; Kotwicki, Tomasz

    2014-07-28

    According to the Scoliosis Research Society (SRS), idiopathic scoliosis (IS) is a curvature of more than 10° Cobb angle, affecting 2-3% of pediatric population. Idiopathic scoliosis accounts for 80% of all scoliosis cases. Non-operative principles in the therapy of idiopathic scoliosis, including Scoliosis Research Society (SRS) criteria and guidelines proposed by the experts of the Society on Scoliosis Orthopedic and Rehabilitation Treatment (SOSORTS) were presented. The possibility to carry out quality of life assessments in a conservative procedure was also demonstrated. Based on the natural history of idiopathic scoliosis, SRS criteria, SOSORT 2008 experts' opinion and the knowledge of the possibilities of psychological assessment of conservative IS treatment, rules were proposed regarding nonsurgical IS therapy procedures, with special consideration being paid to the proper treatment start time (age, Risser test, biological maturity, Cobb angle), possibility of curvature progression, the importance of physiotherapy and psychological assessment. The knowledge of SRS criteria and SOSORT guidelines regarding the conservative treatment of IS are essential for proper treatment (the right time to start treatment), and supports establishment of interdisciplinary treatment teams, consisting of a physician, a physiotherapist, an orthopedic technician and a psychologist.

  3. International guidelines for prevention and management of post-operative chronic pain following inguinal hernia surgery

    DEFF Research Database (Denmark)

    Alfieri, S; Amid, P K; Campanelli, G

    2011-01-01

    To provide uniform terminology and definition of post-herniorrhaphy groin chronic pain. To give guidelines to the scientific community concerning the prevention and the treatment of chronic groin and testicular pain....

  4. NDMA guidelines on management of nuclear and radiological emergencies

    International Nuclear Information System (INIS)

    Abani, M.C.

    2011-01-01

    The National Disaster Management Authority (NDMA), ever since it's formation as an apex policy making body for the country in the field of disaster management, has formulated a set of guidelines to assist the various ministries, states and stakeholders in preparing their plans to handle different types of disasters. The guidelines on management of nuclear and radiological emergencies assume great importance in the present context, as our country has very ambitious programme to exploit nuclear energy for peaceful uses. Though, we have an enviable and impeccable record of safety and virtually fail-safe operations in all our nuclear establishments, the possibility, however, remote it may be, of human error, systems failure, sabotage, earthquake, floods, terrorist attacks etc leading to the release of radioactive material in the public domain, cannot be entirely ruled out. With this view, it was decided to prepare the national guidelines by NDMA to manage any nuclear/radiological emergency in public domain. Through these guidelines, we aim to further strengthen our existing nuclear/radiological emergency management framework and generate public awareness, which will go a long way in allaying misapprehensions, if any, amongst the public about the country's nuclear programme. Like in all our guidelines for handling of different types of the disasters, in these Guidelines also, maximum emphasis has been laid on the prevention of nuclear and radiological emergencies, along with a detailed consideration of all other elements of the disaster management continuum. The national guidelines have been prepared and a consensus was arrived on various issues, after widespread consultations and elaborates discussions amongst experts as well as stakeholders. It is assumed that once these guidelines are implemented by the stakeholders and converted into action plans followed by SOPs that will further reduce the chances of accidents in the nuclear arena. (author)

  5. Regulations and guidelines from the manufacturers' point of view

    International Nuclear Information System (INIS)

    Orth, K.H.

    1977-01-01

    Work on regulations and guidelines is a prerequisite for a better utilization of capacities, for improvements with regard to the licensing procedure and for a more efficient use of the available potential of engineers at the manufacturers' side who, freed from routine tasks, might be charged with further improving the safety of plants. Regulations and guidelines enable a shortening of the planning and building time, an employment of well-tried techniques and directions, multiple use of manufacturing documents, a reduction of the risks to be met in the planning, construction and start-up phases. They enable mass-production of components to be finished at a fixed date, a standardized operation manual and standardized staff training. Cooperation of nuclear power plant manufacturers in drawing up regulations and guidelines is thus not only an issue for the present, but also an investment for the future. (orig./HP) [de

  6. Primary care guidelines

    DEFF Research Database (Denmark)

    Ijäs, Jarja; Alanen, Seija; Kaila, Minna

    2009-01-01

    OBJECTIVE: To describe the adoption of the national Hypertension Guideline in primary care and to evaluate the consistency of the views of the health centre senior executives on the guideline's impact on clinical practices in the treatment of hypertension in their health centres. DESIGN: A cross...... Guideline. RESULTS: Data were available from 143 health centres in Finland (49%). The views of head physicians and senior nursing officers on the adoption of the Hypertension Guideline were not consistent. Head physicians more often than senior nursing officers (44% vs. 29%, p ...: Hypertension Guideline recommendations that require joint agreements between professionals are less often adopted than simple, precise recommendations. More emphasis on effective multidisciplinary collaboration is needed....

  7. Measure Guideline. Wood Window Repair, Rehabilitation, and Replacement

    Energy Technology Data Exchange (ETDEWEB)

    Baker, P. [Building Science Corporation, Somerville, MA (United States); Eng, P. [Building Science Corporation, Somerville, MA (United States)

    2012-12-01

    This measure guideline provides information and guidance on rehabilitating, retrofitting, and replacing existing window assemblies in residential construction. The intent is to provide information regarding means and methods to improve the energy and comfort performance of existing wood window assemblies in a way that takes into consideration component durability, in-service operation, and long term performance of the strategies.

  8. Safety Standard for Hydrogen and Hydrogen Systems: Guidelines for Hydrogen System Design, Materials Selection, Operations, Storage and Transportation. Revision

    Science.gov (United States)

    1997-01-01

    The NASA Safety Standard, which establishes a uniform process for hydrogen system design, materials selection, operation, storage, and transportation, is presented. The guidelines include suggestions for safely storing, handling, and using hydrogen in gaseous (GH2), liquid (LH2), or slush (SLH2) form whether used as a propellant or non-propellant. The handbook contains 9 chapters detailing properties and hazards, facility design, design of components, materials compatibility, detection, and transportation. Chapter 10 serves as a reference and the appendices contained therein include: assessment examples; scaling laws, explosions, blast effects, and fragmentation; codes, standards, and NASA directives; and relief devices along with a list of tables and figures, abbreviations, a glossary and an index for ease of use. The intent of the handbook is to provide enough information that it can be used alone, but at the same time, reference data sources that can provide much more detail if required.

  9. Guidelines for ground motion definition for the eastern United States

    International Nuclear Information System (INIS)

    Gwaltney, R.C.; Aramayo, G.A.; Williams, R.T.

    1985-06-01

    Guidelines for the determination of earthquake ground motion definition for the eastern United States are established here. Both far-field and near-field guidelines are given. The guidelines were based on an extensive review of the current procedures for specifying ground motion in the United States. Both empirical and theoretical procedures were used in establishing the guidelines because of the low seismicity in the eastern United States. Only a few large- to great-sized earthquakes (M/sub s/ > 7.5) have occurred in this region, no evidence of tectonic surface ruptures related to historic or Holocene earthquakes has been found, and no currently active plate boundaries of any kind are known in this region. Very little instrumented data have been gathered in the East. Theoretical procedures are proposed so that in regions of almost no data, a reasonable level of seismic ground motion activity can be assumed. The guidelines are to be used to develop the safe shutdown earthquake (SSE). A new procedure for establishing the operating basis earthquake (OBE) is proposed, in particular for the eastern United States. The OBE would be developed using a probabilistic assessment of the geological conditions and the recurrence of seismic events at a site. These guidelines should be useful in development of seismic design requirements for future reactors. 17 refs., figs., tabs

  10. Radiological risk comparison guidelines

    International Nuclear Information System (INIS)

    Hallinan, E.J.; Muhlestein, L.D.; Brown, L.F.; Yoder, R.E.

    1992-01-01

    An important aspect of DOE safety analyses is estimating potential accident risk. The estimates are used to: determine if additional controls are needed, identify Safety Class Items, and demonstrate adequate risk reduction. Thus, guidelines are needed to measure comparative risks. The Westinghouse M ampersand O Nuclear Facility Safety Committee and the Safety Envelope Working Group have developed radiological risk guidelines for comparing the risks from individual accident analyses. These guidelines were prepared under contract with the US Department of Energy. These guidelines are based on historical DOE guidelines and current requirements, and satisfy DOE and technical community proposals. for goals that demonstrate acceptable risk. The guidelines consist of a frequency versus consequence curve for credible accidents. Offsite and onsite guidelines are presented. The offsite risk acceptance guidelines are presented in Figure 1. The guidelines are nearly isorisk for anticipated events where impacts are chronic, and provide additional reduction for unlikely events where impacts may be acute and risk uncertainties may be significant. The guidelines are applied to individual release accident scenarios where a discrete frequency and consequence has been estimated. The guideline curves are not to be used for total risk assessments. Common cause events are taken into consideration only for an individual facility. Frequencies outside the guideline range are considered to be local site option (analyst judgement) as far as assessments of risk acceptance are concerned. If the curve is exceeded, then options include either a more detailed analysis or imposing additional preventive or mitigative features. Another presentation discusses implementation in detail. Additional work is needed to provide risk comparison guidelines for releases from multiple facilities and for toxic releases

  11. Quality Guidelines

    Science.gov (United States)

    ... this page: https://medlineplus.gov/criteria.html MedlinePlus Quality Guidelines To use the sharing features on this ... materials must also meet our existing quality guidelines. Quality, authority and accuracy of health content The organization's ...

  12. 49 CFR Appendix D to Part 26 - Mentor-Protégé Program Guidelines

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Mentor-Protégé Program Guidelines D Appendix D... D to Part 26—Mentor-Protégé Program Guidelines (A) The purpose of this program element is to further... and assistance from other firms. To operate a mentor-protégé program, a recipient must obtain the...

  13. Which points deserve special attention in the new guidelines on X-ray use (testing guidelines for experts and quality assurance guidelines)?

    International Nuclear Information System (INIS)

    Ewen, K.; Lauber, I.

    2004-01-01

    Two important guidelines for the application of X-rays in medicine became effective on 1 October 2003 and 1 December 2003. These are testing guidelines for experts and quality assurance guidelines. Both guidelines are very extensive and not always easy to interpret. In the present paper the authors try to explain in detail some chapters important for radiology and to make the necessary technical background transparent. Both authors took an essential part in forming the guidelines. (orig.) [de

  14. Development of guidelines for seismic isolation in Italy

    International Nuclear Information System (INIS)

    Olivieri, M.; Martelli, A.; Bettinali, F.; Bonacina, G.

    1992-01-01

    The first activities on seismic isolation that were performed in Italy concerned the preparation of a proposal for design guidelines for nuclear power plants using the high damping steel-laminated elastomer bearings (HDLRBs). They were jointly initiated by ENEA-RIN and GE Nuclear Energy in 1988, with the co-operation of ISMES and the support of experts of ENEA-DISP and Bechtel National Inc. The features of the guidelines proposal were outlined at the First Post-SMiRT Conference Seminar on Seismic Base Isolation of Nuclear Power Facilities (San Francisco, 1989). The full text of the document was published in the Journal 'Energia Nucleare' in 1990, in a tentative form, to allow for a broad review. A summary of the main items - together with some first results of R and D studies performed in support to guidelines development - was also reported in a paper which was recently published by the Journal 'Nuclear Technology' (February 1992). A first revision of the document is being prepared and will be soon published: it accounts for both comments received - for instance, by the American Society of Civil Engineers (ASCE), ENEA-DISP and the Malaysian Rubber Producers' Association (MRPRA) - and the first results of R and D studies in progress in Italy and the USA. These activities have recently been extended - as part of a cooperation with the Italian Standard Authority (UNI) - to other antiseismic devices, for application to civil buildings and non-nuclear plants. A co-operation of ENEA, ENEL and ISMES has also been started with the National Seismic Service to help it in the assessment of national regulations. Furthermore, extension of the aforesaid guidelines document to nuclear reactors using bearings different from the HDLRB has been planned, under the sponsorship of the Commission of the European communities: this work will be performed by ENEA, with the cooperation of ALGA, ISMES, ANSALDO and the Nuclear Engineering Laboratory (LIN) of the Bologna University, and the

  15. Preliminary System Design of the SWRL Financial System.

    Science.gov (United States)

    Ikeda, Masumi

    The preliminary system design of the computer-based Southwest Regional Laboratory's (SWRL) Financial System is outlined. The system is designed to produce various management and accounting reports needed to maintain control of SWRL operational and financial activities. Included in the document are descriptions of the various types of system…

  16. Guidelines for equipment and staffing of radiotherapy facilities in the European countries: Final results of the ESTRO-HERO survey

    DEFF Research Database (Denmark)

    Dunscombe, Peter; Grau, Cai; Defourny, Noémie

    2014-01-01

    of guidelines for equipment and staffing and selected operational issues. Twenty-nine countries provided full or partial evaluable responses. RESULTS: The availability of guidelines across Europe is far from uniform. The metrics used for capital and human resources are variable. There seem to have been no major...... guidelines suggesting developments in clinical radiotherapy are moving faster than guideline updating. CONCLUSION: The efficient provision of safe, high quality radiotherapy services would benefit from the availability of well-structured guidelines for capital and human resources, based on agreed upon...

  17. Preliminary design package for prototype solar heating system

    Energy Technology Data Exchange (ETDEWEB)

    1978-12-01

    A summary is given of the preliminary analysis and design activity on solar heating systems. The analysis was made without site specific ata other than weather; therefore, the results indicate performance expected under these special conditions. Major items in this report include systeem candidates, design approaches, trade studies and other special data required to evaluate the preliminary analysis and design. The program calls for the development and delivery of eight prototype solar heating and coolin systems for installation and operational test. Two-heating and six heating and cooling units will be delivered for Single Family Residences (SFR), Multi-Family Residences (MFR) and commercial applications.

  18. Guidelines for earthquake ground motion definition for the Eastern United States

    International Nuclear Information System (INIS)

    Gwaltney, R.C.; Aramayo, G.A.; Williams, R.T.

    1985-01-01

    Guidelines for the determination of earthquake ground-motion definition for the eastern United States are established in this paper. Both far-field and near-field guidelines are given. The guidelines were based on an extensive review of the current procedures for specifying ground motion in the United States. Both empirical and theoretical procedures were used in establishing the guidelines because of the low seismicity in the eastern United States. Only a few large to great (M > 7.5) sized earthquakes have occurred in this region, no evidence of tectonic surface ruptures related to historic or Holocene earthquakes have been found, and no currently active plate boundaries of any kind are known in this region. Very little instrumented data has been gathered in the East. Theoretical procedures are proposed so that in regions of almost no data a reasonable level of seismic ground motion activity can be assumed. The guidelines are to be used to develop the Safe Shutdown Earthquake, SSE. A new procedure for establishing the Operating Basis Earthquake, OBE, is proposed, in particular for the eastern United States. The OBE would be developed using a probabilistic assessment of the geological conditions and the recurrence of seismic events at a site. These guidelines should be useful in development of seismic design requirements for future reactors

  19. Preliminary studies for the determination of alpha emitters using the gross alpha coprecipitation methods

    International Nuclear Information System (INIS)

    Suarez-Navarro, J. A.; Pujol, L.; Suarez, J. A.; Pablo, M. A. de

    2003-01-01

    The radiological quality of drinking water in Spain is regulated by Nuclear Security Guideline No, 7.7 (Rev.1) of the Nuclear Security Council (NSC). this guideline establishes the protocol to follow when the radiological level exceeds 0,1 Bq.l''1. When this level is passed, the responsible alpha emitter must be identified; ''210 Po, ''226Ra, ''230Th, ''239Pu, ''224Ra, ''234 U and ''138 U. Activity due to these isotopes is usually determined using alpha spectrometry with semiconductor detectors. This method allows the activity of the alpha emitters to be determined with a good sensitivity. however, it requires long radiochemical isolations and long counting times, so the method is not suitable for rough estimate radiological analysis. In this preliminary work, we present the conditioning of the sample-precipitate that is essential for further radiochemical isolations. (Author) 9 refs

  20. Guidelines 2.0: systematic development of a comprehensive checklist for a successful guideline enterprise

    Science.gov (United States)

    Schünemann, Holger J.; Wiercioch, Wojtek; Etxeandia, Itziar; Falavigna, Maicon; Santesso, Nancy; Mustafa, Reem; Ventresca, Matthew; Brignardello-Petersen, Romina; Laisaar, Kaja-Triin; Kowalski, Sérgio; Baldeh, Tejan; Zhang, Yuan; Raid, Ulla; Neumann, Ignacio; Norris, Susan L.; Thornton, Judith; Harbour, Robin; Treweek, Shaun; Guyatt, Gordon; Alonso-Coello, Pablo; Reinap, Marge; Brožek, Jan; Oxman, Andrew; Akl, Elie A.

    2014-01-01

    Background: Although several tools to evaluate the credibility of health care guidelines exist, guidance on practical steps for developing guidelines is lacking. We systematically compiled a comprehensive checklist of items linked to relevant resources and tools that guideline developers could consider, without the expectation that every guideline would address each item. Methods: We searched data sources, including manuals of international guideline developers, literature on guidelines for guidelines (with a focus on methodology reports from international and national agencies, and professional societies) and recent articles providing systematic guidance. We reviewed these sources in duplicate, extracted items for the checklist using a sensitive approach and developed overarching topics relevant to guidelines. In an iterative process, we reviewed items for duplication and omissions and involved experts in guideline development for revisions and suggestions for items to be added. Results: We developed a checklist with 18 topics and 146 items and a webpage to facilitate its use by guideline developers. The topics and included items cover all stages of the guideline enterprise, from the planning and formulation of guidelines, to their implementation and evaluation. The final checklist includes links to training materials as well as resources with suggested methodology for applying the items. Interpretation: The checklist will serve as a resource for guideline developers. Consideration of items on the checklist will support the development, implementation and evaluation of guidelines. We will use crowdsourcing to revise the checklist and keep it up to date. PMID:24344144

  1. [Implementation of Study Results in Guidelines and Adherence to Guidelines in Clinical Practice].

    Science.gov (United States)

    Waldfahrer, F

    2016-04-01

    Guidelines were introduced in hospital and practice-based otorhinolaryngology in the 1990s, and have been undergoing further development ever since. There are currently 20 guidelines on file at the German Society of Oto-Rhino-Laryngology, Head and Neck Surgery. The Society has cooperated in a further 34 guidelines. The quality of the guidelines has been continually improved by concrete specifications put forward by the Association of the Scientific Medical Societies in Germany [Arbeitsgemeinschaft der Wissenschaftlichen Medizinischen Fachgesellschaften e.V.]. Since increasing digitalisation has made access to scientific publications quicker and more simple, relevant study results can be incorporated in guidelines more easily today than in the analogue world. S2e and S3 guidelines must be based on a formal literature search with subsequent evaluation of the evidence. The consensus procedure for S2k guidelines is also regulated. However, the implementation of guidelines in routine medical practice must still be considered inadequate, and there is still a considerable need for improvement in adherence to these guidelines. © Georg Thieme Verlag KG Stuttgart · New York.

  2. IMAGE Programming Guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Stehfest, E; De Waal, L.

    2010-09-15

    This document describes the requirements and guidelines for the software of the IMAGE system. The motivation for this report was a substantial restructuring of the source code for IMAGE version 2.5. The requirements and guidelines relate to design considerations as well as to aspects of maintainability and portability. The design considerations determine guidelines about subjects, such as program structure, model hierarchy, the use of data modules, and the error message system. Maintainability and portability aspects determine the guidelines on, for example, the Fortran 90 standard, naming conventions, code lay-out, and internal documentation.

  3. Preliminary design package for solar collector and solar pump

    Science.gov (United States)

    1978-01-01

    A solar-operated pump using an existing solar collector, for use on solar heating and cooling and hot water systems is described. Preliminary design criteria of the collector and solar-powered pump is given including: design drawings, verification plans, and hazard analysis.

  4. Preliminary closed Brayton cycle study for a space reactor application

    International Nuclear Information System (INIS)

    Guimaraes, Lamartine Nogueira Frutuoso; Carvalho, Ricardo Pinto de; Camillo, Giannino Ponchio

    2007-01-01

    The Nuclear Energy Division (ENU) of the Institute for Advanced Studies (IEAv) has started a preliminary design study for a Closed Brayton Cycle Loop (CBCL) aimed at a space reactor application. The main objectives of the study are to establish a starting concept for the CBCL components specifications, and to develop a demonstrative simulator of CBCL in nominal operation conditions. The ENU/IEAv preliminary design study is developing the CBCL around the NOELLE 60290 turbo machine. The actual nuclear reactor study is being conducted independently. Because of that, a conventional heat source is being used for the CBCL, in this preliminary design phase. This paper describes the steady state simulator of the CBCL operating with NOELLE 60290 turbo machine. In principle, several gases are being considered as working fluid, as for instance: air, helium, nitrogen, CO2 and gas mixtures such as helium and xenon. At this moment the simulator is running with Helium as the working fluid. Simplified models of heat and mass transfer are being developed to simulate thermal components. Future efforts will focus on keeping track of the modifications being implemented at the NOELLE 60290 turbo machine in order to build the CBCL. (author)

  5. Preliminary closed Brayton cycle study for a space reactor application

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Lamartine Nogueira Frutuoso; Carvalho, Ricardo Pinto de [Institute for Advanced Studies, Sao Jose dos Campos, SP (Brazil)]. E-mail: guimarae@ieav.cta.br; Camillo, Giannino Ponchio [Instituto Tecnologico de Aeronautica (ITA), Sao Jose dos Campos, SP (Brazil)]. E-mail: gianninocamillo@gmail.com

    2007-07-01

    The Nuclear Energy Division (ENU) of the Institute for Advanced Studies (IEAv) has started a preliminary design study for a Closed Brayton Cycle Loop (CBCL) aimed at a space reactor application. The main objectives of the study are to establish a starting concept for the CBCL components specifications, and to develop a demonstrative simulator of CBCL in nominal operation conditions. The ENU/IEAv preliminary design study is developing the CBCL around the NOELLE 60290 turbo machine. The actual nuclear reactor study is being conducted independently. Because of that, a conventional heat source is being used for the CBCL, in this preliminary design phase. This paper describes the steady state simulator of the CBCL operating with NOELLE 60290 turbo machine. In principle, several gases are being considered as working fluid, as for instance: air, helium, nitrogen, CO2 and gas mixtures such as helium and xenon. At this moment the simulator is running with Helium as the working fluid. Simplified models of heat and mass transfer are being developed to simulate thermal components. Future efforts will focus on keeping track of the modifications being implemented at the NOELLE 60290 turbo machine in order to build the CBCL. (author)

  6. Workshop presentation: research guidelines for Construction Management

    OpenAIRE

    Marco Alvise Bragadin

    2013-01-01

    Nowadays the European economic system challenges the construction sector to take part to industrial recovery of western countries. In co-operation with the Construction Production research group of the Tampere University of of research about construction management tools and methods were detected. Research guidelines: 1) Construction management: tools and methods to manage construction projects 2) environmental impact of construction projects 3) construction management and safety 4) project p...

  7. Areva's water chemistry guidebook with chemistry guidelines for next generation plants (AREVA EPRTM reactors)

    International Nuclear Information System (INIS)

    Ryckelynck, N.; Chahma, F.; Caris, N.; Guillermier, P.; Brun, C.; Caron-Charles, M.; Lamanna, L.; Fandrich, J.; Jaeggy, M.; Stellwag, B.

    2012-09-01

    Over the years, AREVA globally has maintained a strong expertise in LWR water chemistry and has been focused on minimizing short-term and long-term detrimental effects of chemistry for startup, operation and shutdown chemistry for all key plant components (material integrity and reliability, promote optimal thermal performances, etc.) and fuel. Also AREVA is focused on minimizing contamination and equipment/plant dose rates. Current Industry Guidelines (EPRI, VGB, etc.) provide utilities with selected chemistry guidance for the current operating fleet. With the next generation of PWR plants (e.g. AREVA's EPR TM reactor), materials of construction and design have been optimized based on industry lessons learned over the last 50+ years. To support the next generation design, AREVA water chemistry experts, have subsequently developed a Chemistry Guidebook with chemistry guidelines based on an analysis of the current international practices, plant operating experience, R and D data and calculation codes now available and/or developed by AREVA. The AREVA LWR chemistry Guidebook can be used to help resolve utility and safety authority questions and addresses regulation requirement questions/issues for next generation plants. The Chemistry Guidebook provides water chemistry guidelines for primary coolant, secondary side circuit and auxiliary systems during startup, normal operation and shutdown conditions. It also includes conditioning and impurity limits, along with monitoring locations and frequency requirements. The Chemistry Guidebook Guidelines will be used as a design reference for AREVA's next generation plants (e.g. EPR TM reactor). (authors)

  8. Waste Feed Delivery System Phase 1 Preliminary RAM Analysis

    International Nuclear Information System (INIS)

    DYKES, A.A.

    2000-01-01

    This report presents the updated results of the preliminary reliability, availability, and maintainability (RAM) analysis of selected waste feed delivery (WFD) operations to be performed by the Tank Farm Contractor (TFC) during Phase I activities in support of the Waste Treatment and Immobilization Plant (WTP). For planning purposes, waste feed tanks are being divided into five classes in accordance with the type of waste in each tank and the activities required to retrieve, qualify, and transfer waste feed. This report reflects the baseline design and operating concept, as of the beginning of Fiscal Year 2000, for the delivery of feed from three of these classes, represented by source tanks 241-AN-102, 241-AZ-101 and 241-AN-105. The preliminary RAM analysis quantifies the potential schedule delay associated with operations and maintenance (OBM) field activities needed to accomplish these operations. The RAM analysis is preliminary because the system design, process definition, and activity planning are in a state of evolution. The results are being used to support the continuing development of an O and M Concept tailored to the unique requirements of the WFD Program, which is being documented in various volumes of the Waste Feed Delivery Technical Basis (Carlson. 1999, Rasmussen 1999, and Orme 2000). The waste feed provided to the WTP must: (1) meet limits for chemical and radioactive constituents based on pre-established compositional envelopes (i.e., feed quality); (2) be in acceptable quantities within a prescribed sequence to meet feed quantities; and (3) meet schedule requirements (i.e., feed timing). In the absence of new criteria related to acceptable schedule performance due to the termination of the TWRS Privatization Contract, the original criteria from the Tank Waste Remediation System (77443s) Privatization Contract (DOE 1998) will continue to be used for this analysis

  9. Enhanced Accident Tolerant Fuels for LWRS - A Preliminary Systems Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Gilles Youinou; R. Sonat Sen

    2013-09-01

    The severe accident at Fukushima Daiichi nuclear plants illustrates the need for continuous improvements through developing and implementing technologies that contribute to safe, reliable and cost-effective operation of the nuclear fleet. Development of enhanced accident tolerant fuel contributes to this effort. These fuels, in comparison with the standard zircaloy – UO2 system currently used by the LWR industry, should be designed such that they tolerate loss of active cooling in the core for a longer time period (depending on the LWR system and accident scenario) while maintaining or improving the fuel performance during normal operations, operational transients, and design-basis events. This report presents a preliminary systems analysis related to most of these concepts. The potential impacts of these innovative LWR fuels on the front-end of the fuel cycle, on the reactor operation and on the back-end of the fuel cycle are succinctly described without having the pretension of being exhaustive. Since the design of these various concepts is still a work in progress, this analysis can only be preliminary and could be updated as the designs converge on their respective final version.

  10. Preliminary performance and operating results from the integrated dry NOx/SO2 emissions control system

    International Nuclear Information System (INIS)

    Hunt, T.; Schott, G.; Smith, R.; Muzio, L.; Jones, D.; Mali E.; Arrigoni, T.

    1993-01-01

    The Integrated Dry NO x /SO 2 Emissions Control System was installed at Public Service Company of Colorado's Arapaho 4 generating station in 1992 in cooperation with the U.S. Department of Energy (DOE) and and the Electric Power Research Institute (EPRI). This full scale 100 MWe demonstration combines low-NO x burners, overfire air, and selective noncatalytic reduction (SNCR) for NO x control and dry sorbent injection with humidification for SO 2 control. Operation and testing of the Integrated Dry NO x /SO 2 Emissions Control System began in August 1992 and will continue through mid 1994. Preliminary results of the NO x control technologies show that the original system goal of 70% NO x removal has been easily met and that NO x removals of up to 80% are possible at full load with the combustion and SNCR systems. Testing of the dry sorbent injection system with low sulfur coal began in April 1993 using a calcium-based reagent. A maximum SO 2 removal of 40% has been achieved with duct injection of commercial calcium hydroxide and humidification to a 25 degrees F approach to saturation. Sodium-based dry sorbent injection is expected to achieved up to a 70% SO 2 reduction

  11. The neutral beam test facility cryopumping operation: preliminary analysis and design of the cryogenic system

    International Nuclear Information System (INIS)

    Gravil, B.; Henry, D.; Cordier, J.J.; Hemsworth, R.; Van Houtte, D.

    2004-01-01

    The ITER neutral beam heating and current drive system is to be equipped with a cryosorption cryopump made up of 12 panels connected in parallel, refrigerated by 4.5 K 0.4 MPa supercritical helium. The pump is submitted to a non homogeneous flux of H 2 or D 2 molecules, and the absorbed flux varies from 3 Pa.m -3 .s -1 to 35 Pa.m -3 .s -1 . In the frame of the 'ITER first injector and test facility CSU-EFDA task' (TW3-THHN-IITF1), the ITER reference cryo-system and cryo-plant designs have been assessed and compared to optimised designs devoted to the Neutral Beam Test Facility (NBTF). The 4.5 K cryo-panel, which has a mass of about 1000 kg, must be periodically regenerated up to 90 K and occasionally to 470 K. The cool-down time after regeneration depends strongly on the refrigeration capacity. Fast regeneration and cool-down of the cryo-panels are not considered a priority for the test facility operation, and an analysis of the consequences of a limited cold power refrigerator on the cooling down time has been carried out and will be discussed. This paper presents a preliminary evaluation of the NBTF cryo-plant and the associated process flow diagram. (authors)

  12. Steps forward in plant operation. From guidelines to a well-structured, usable and maintainable procedure system

    International Nuclear Information System (INIS)

    Forzano, P.; Castagna, P.

    1998-01-01

    The know-how of plant operation, in normal or emergency situations, and maintenance, is typically written in the form of guidelines. Although technical literature is structured in chapters and paragraphs, this type of formalization is still to the level of a 'good practice'. It is informal and subject to individual ability and competence. For many human activities that have intrinsically an high level of formalization, like procedures, it is advisable to analyze the formalism, to extract a set of rules from it, and to collect all the rules in a standard, that should be applicable to a range of specific situations. This papers presents DIAM, a methodology and a tool for procedure management, inspired by practical day-by-day issues: it embeds drawing and documentation standards and offers some new features like automatic flow diagramming and the structuring of large diagrams into pages, the congruence of step names and line paths, and the automatic printout of the procedure book. The automation of many activities offered by DIAM leads to a dramatic reduction in time for drawing productions and think document management in a completely new mode, allowing to abandon the old era of document patching and opening the new era of top quality drawings. (author)

  13. The new hypertension guidelines.

    Science.gov (United States)

    Stern, Ralph H

    2013-10-01

    The Canadian Hypertension Education Program (CHEP) has published guidelines annually since 2000. The CHEP guidelines are a model of concise, comprehensive, up-to-date, evidence-rated guidelines for physicians who diagnose and treat hypertension. The guidelines address measurement of blood pressure and the definition of hypertension, secondary hypertension evaluation and treatment, and blood pressure targets and medication choices in patients with and without compelling indications. This review describes CHEP's process for developing guidelines and provides an overview of the 2013 recommendations. ©2013 Wiley Periodicals, Inc.

  14. Preliminary design for a maglev development facility

    Energy Technology Data Exchange (ETDEWEB)

    Coffey, H.T.; He, J.L.; Chang, S.L.; Bouillard, J.X.; Chen, S.S.; Cai, Y.; Hoppie, L.O.; Lottes, S.A.; Rote, D.M. (Argonne National Lab., IL (United States)); Zhang, Z.Y. (Polytechnic Univ., Brooklyn, NY (United States)); Myers, G.; Cvercko, A. (Sterling Engineering, Westchester, IL (United States)); Williams, J.R. (Alfred Benesch and Co., Chicago, IL (United States))

    1992-04-01

    A preliminary design was made of a national user facility for evaluating magnetic-levitation (maglev) technologies in sizes intermediate between laboratory experiments and full-scale systems. A technical advisory committee was established and a conference was held to obtain advice on the potential requirements of operational systems and how the facility might best be configured to test these requirements. The effort included studies of multiple concepts for levitating, guiding, and propelling maglev vehicles, as well as the controls, communications, and data-acquisition and -reduction equipment that would be required in operating the facility. Preliminary designs for versatile, dual 2-MVA power supplies capable of powering attractive or repulsive systems were developed. Facility site requirements were identified. Test vehicles would be about 7.4 m (25 ft) long, would weigh form 3 to 7 metric tons, and would operate at speeds up to 67 m/s (150 mph) on a 3.3-km (2.05-mi) elevated guideway. The facility would utilize modular vehicles and guideways, permitting the substitution of levitation, propulsion, and guideway components of different designs and materials for evaluation. The vehicle would provide a test cell in which individual suspension or propulsion components or subsystems could be tested under realistic conditions. The system would allow economical evaluation of integrated systems under varying weather conditions and in realistic geometries.

  15. Guidelines for preclinical animal research in ALS/MND: A consensus meeting.

    Science.gov (United States)

    Ludolph, Albert C; Bendotti, Caterina; Blaugrund, Eran; Chio, Adriano; Greensmith, Linda; Loeffler, Jean-Philippe; Mead, Richard; Niessen, Heiko G; Petri, Susanne; Pradat, Pierre-Francois; Robberecht, Wim; Ruegg, Markus; Schwalenstöcker, Birgit; Stiller, Detlev; van den Berg, Leonard; Vieira, Fernando; von Horsten, Stephan

    2010-01-01

    The development of therapeutics for ALS/MND is largely based on work in experimental animals carrying human SOD mutations. However, translation of apparent therapeutic successes from in vivo to the human disease has proven difficult and a considerable amount of financial resources has been apparently wasted. Standard operating procedures (SOPs) for preclinical animal research in ALS/MND are urgently required. Such SOPs will help to establish SOPs for translational research for other neurological diseases within the next few years. To identify the challenges and to improve the research methodology, the European ALS/MND group held a meeting in 2006 and published guidelines in 2007 (1). A second international conference to improve the guidelines was held in 2009. These second and improved guidelines are dedicated to the memory of Sean F. Scott.

  16. Relationships between post operative pain management and short term functional mobility in total knee arthroplasty patients with a femoral nerve catheter: A preliminary study

    Directory of Open Access Journals (Sweden)

    Ward Sarah

    2011-02-01

    Full Text Available Abstract Background Effective pain management following total knee arthroplasty (TKA is fundamental in achieving positive rehabilitation outcomes. The purpose of our study was to investigate post operative pain management in relation to short term functional mobility in an intervention group receiving concomitant use of an IV narcotic PCA and a continuous infusion of local anaesthetic via a femoral nerve catheter (CFNC, compared to a group receiving narcotic PCA alone. This was a preliminary study conducted to establish an appropriate design for a larger investigative study. Methods A prospective design was used to measure the effect of a CFNC on post operative pain management and functional mobility prior to hospital discharge. The amount of fentanyl used, pain and nausea scores, timed up and go (TUG tests and active range of knee movement (AROM were used to compare a CFNC and supplemental narcotic patient controlled analgesia (PCA group (n = 27 with a PCA only group (n = 25. Results The CFNC group used significantly less fentanyl than the PCA only group (p s = .505 p s = .529 p s = .328, p = .034 Conclusions In this small preliminary study improved TUG performance at Day 4 post op was not influenced by the use of a CFNC but was positively correlated with male gender, preoperative performance, time elapsed since last oral analgesia and pain score. However AROM was decreased in the CFNC group suggesting further research on the relationship between CFNCs, local anaesthetic concentration and quadriceps strength should be incorporated in the follow up study's design.

  17. Preliminary tests of the electrostatic plasma accelerator

    Science.gov (United States)

    Aston, G.; Acker, T.

    1990-01-01

    This report describes the results of a program to verify an electrostatic plasma acceleration concept and to identify those parameters most important in optimizing an Electrostatic Plasma Accelerator (EPA) thruster based upon this thrust mechanism. Preliminary performance measurements of thrust, specific impulse and efficiency were obtained using a unique plasma exhaust momentum probe. Reliable EPA thruster operation was achieved using one power supply.

  18. Guidelines for computer security in general practice.

    Science.gov (United States)

    Schattner, Peter; Pleteshner, Catherine; Bhend, Heinz; Brouns, Johan

    2007-01-01

    As general practice becomes increasingly computerised, data security becomes increasingly important for both patient health and the efficient operation of the practice. To develop guidelines for computer security in general practice based on a literature review, an analysis of available information on current practice and a series of key stakeholder interviews. While the guideline was produced in the context of Australian general practice, we have developed a template that is also relevant for other countries. Current data on computer security measures was sought from Australian divisions of general practice. Semi-structured interviews were conducted with general practitioners (GPs), the medical software industry, senior managers within government responsible for health IT (information technology) initiatives, technical IT experts, divisions of general practice and a member of a health information consumer group. The respondents were asked to assess both the likelihood and the consequences of potential risks in computer security being breached. The study suggested that the most important computer security issues in general practice were: the need for a nominated IT security coordinator; having written IT policies, including a practice disaster recovery plan; controlling access to different levels of electronic data; doing and testing backups; protecting against viruses and other malicious codes; installing firewalls; undertaking routine maintenance of hardware and software; and securing electronic communication, for example via encryption. This information led to the production of computer security guidelines, including a one-page summary checklist, which were subsequently distributed to all GPs in Australia. This paper maps out a process for developing computer security guidelines for general practice. The specific content will vary in different countries according to their levels of adoption of IT, and cultural, technical and other health service factors. Making

  19. Cost and Operational Effectiveness Analysis of Aiternative Force Structures for Fulfillment of the United States Marine Corps Operational Support Airlift and Search and Rescue Missions

    National Research Council Canada - National Science Library

    Chase, Eric

    2000-01-01

    This thesis provides a preliminary cost and operational effectiveness analysis of alternative force structures for the United States Marine Corps operational support airlift and search and rescue missions...

  20. Hypertension guidelines and their effects on the health system

    Directory of Open Access Journals (Sweden)

    Konta, Brigitte

    2005-12-01

    Full Text Available Introduction: Hypertension guidelines, which have existed for many years and primarily used in the USA, Canada and Great Britain, are now becoming an issue in Germany. Strong efforts are presently underway for a German version comparable to the guidelines developed for the mentioned countries. The development of guidelines is a part of the implementation system of guidelines in Germany. It covers the mode of operation of the AWMF (work community of the scientific medical subject companies with the clearinghouse for guidelines (CLA and the cooperation with the centre for medical quality (ÄZQ. In the HTA report the real use of the hypertension guidelines shall be investigated for Germany from the development trends and further possibilities of use according to a medical applicability. Economic issues and an optimisation of use are also discussed. Question: The following questions shall be answered in particular: 1. How much are the guidelines used concerning hypertension? 2. Can effects (or their influence be established on the medical procedures? 3. Are there statements available about costs and cost effectiveness? 4. Are there recommendations for further use? Methodology: To answer these questions, a comprehensive literature search was done. No empirical investigation was carried out. From this enquiry 206 articles were checked in detail but not all of them were available in full text. Only those publications which directly dealt with high blood pressure guidelines or articles with a direct reference to the topic have been considered in the HTA report. Publications concerning screening or methods of prevention, medical studies of the hypertension syndrome without a direct reference to guidelines and publications concerned with putting guidelines into action were excluded. Results: After an analysis of the selected literature addressing the topic of hypertension guidelines, it was evident that the use of these guidelines cannot be gathered from

  1. Characterization of the Darwin direct implicit particle-in-cell method and resulting guidelines for operation

    International Nuclear Information System (INIS)

    Gibbons, M.R.; Hewett, D.W.

    1997-01-01

    We investigate the linear dispersion and other properties of the Darwin Direct Implicit Particle-in-cell (DADIPIC) method in order to deduce guidelines for its use in the simulation of long time-scale, kinetic phenomena in plasmas. The Darwin part of this algorithm eliminates the Courant constraint for light propagation across a grid cell in a time step and divides the field solution into several elliptic equations. The direct implicit method is only applied to the electrostatic field relieving the need to resolve plasma oscillations. Linear theory and simulations verifying the theory are used to generate the desired guidelines as well as show the utility of DADIPIC for a wide range of low frequency, electromagnetic phenomena. We find that separation of the fields has made the task of predicting algorithm behavior easier and produced a robust method without restrictive constraints. 20 refs., 11 figs., 3 tabs

  2. Status of NRC approval of EPRI electromagnetic interference susceptibility testing guidelines for digital equipment

    International Nuclear Information System (INIS)

    James, R.W.; Shank, J.W.; Yoder, C.

    1996-01-01

    Historically, nuclear power plants installing digital equipment have been required to conduct expensive, site-specific electromagnetic interference (EMI) surveys to demonstrate that EMI will not affect the operation of sensitive electronic equipment. Consequently, EPRI formed a Utility Working Group which developed a set of generic EMI susceptibility testing guidelines, which were published as an EPRI report in September 1994. These guidelines are based upon EMI survey data obtained from several different plants and include criteria for determining their applicability. The Working Group interacted with NRC staff to obtain NRC approval. In April 1996, the NRC issued a Safety Evaluation Report (SER) endorsing the guidelines as a valid means of demonstrating EMI compatibility. The issuance of this SER was conditional on issuing a revision to the EPRI EMI Guidelines. This paper summarizes the guidelines, the NRC SER, and the current status of Revision 1 to the report

  3. 40 CFR 417.152 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... available (BPT): (a) For normal operation of spray drying towers as defined above, the following values... operation of a spray drying tower, but only when a high rate of wet scrubbing is in operation which produces... CATEGORY Manufacture of Spray Dried Detergents Subcategory § 417.152 Effluent limitations guidelines...

  4. CW operation of the FMIT RFQ accelerator

    International Nuclear Information System (INIS)

    Cornelius, W.D.

    1984-01-01

    Experiences in attaining cw operation of the radio-frequency quadrupole for the Fusion Materials Irradiation Test facility are presented. Modifications of the vacuum system, changes in the rf structure, and operational experiences are discussed, as well as preliminary results of initial beam-characterization measurements. 4 references, 2 figures

  5. IAEA guidance on ageing management for nuclear power plants. Guidance on effective management of the physical ageing of systems, structures and components important to safety for nuclear power plants. Overview. Programmatic guidelines. Component specific guidelines. Review guidelines. Version 1, 2002

    International Nuclear Information System (INIS)

    2002-01-01

    Operational experience shows that excellent plant safety and excellent performance go hand in hand, and that they are achieved by effective leadership and management that includes a unified approach to safety and production. This is also applicable to ageing management. Effective ageing management leads to both enhanced plant safety and enhanced performance and is a prerequisite for long service life. The IAEA project on Safety Aspects of NPP Ageing has produced since 1990 a comprehensive set of programmatic and component specific guidelines on managing ageing, while providing an interactive environment for information exchange and co-operation among practitioners, and has assisted Member States in the application of the guidelines through the provision of training and advice. The objective of the CD-ROM is to preserve the IAEA's guidance on ageing management and to facilitate its retrieval, updating, extension and dissemination in order to help increase the effectiveness of ageing management at nuclear power plants

  6. Guidelines Gas Act. Information and Consultation Document 2001

    International Nuclear Information System (INIS)

    De Groene, P.; Teljeur, E.; Verdonkschot, I.R.

    2001-06-01

    This Information and Consultation Document has been drawn up for the consultation period that will be held prior to the approval of the new Guidelines, in accordance with sections 13 and 18 of the Dutch Gas Act. In determining the topics for discussion in the consultation document, DTe has based its decision on the scope and aim of these Guidelines. In doing so, DTe's objective is to achieve these aims in a responsible manner, with limited interventions in the market. The Guidelines focus firstly on gas transport companies, in so far as they transport gas to supply eligible customers. In the year 2002, customers with an annual off-take of 1 million m 3 or more will be eligible. Secondly, the Guidelines focus on gas storage companies that have a dominant position or are deemed to have a dominant position, in accordance with section 18(2) of the Gas Act. In determining the Guidelines, in accordance with section 13(1) of the Gas Act, the Director of DTe has to take into account the promotion of trade and the promotion of the efficient operation of gas transport companies and users of the gas network. In addition, it appears from the Parliamentary Proceedings that the Guidelines also have the aim of preventing abuse of a dominant position. This document indicates the way DTe intends to achieve the statutory aims referred to above. Partly on the basis of experience in other countries, DTe assumes that realising these aims and creating a 'level playing field' on the Dutch gas market is a gradual process that may take several years. It will not be possible to realise all the conditions for achieving the above-mentioned objectives, as outlined by DTe in the Information and Consultation Document, in 2002. DTe therefore intends to limit the Guidelines for the year 2002 to the conditions that have priority. The aim of the consultation process and the responses of the various markets players is partly to determine the conditions that have priority. For the purposes of

  7. Public informations guidelines

    International Nuclear Information System (INIS)

    1986-06-01

    The purpose of these Public Information Guidelines is to provide principles for the implementation of the NWPA mandate and the Mission Plan requirements for the provision of public information. These Guidelines set forth the public information policy to be followed by all Office of Civilian Radioactive Waste Management (OCRWM) performance components. The OCRWM offices should observe these Guidelines in shaping and conducting public information activities

  8. Public informations guidelines

    Energy Technology Data Exchange (ETDEWEB)

    None

    1986-06-01

    The purpose of these Public Information Guidelines is to provide principles for the implementation of the NWPA mandate and the Mission Plan requirements for the provision of public information. These Guidelines set forth the public information policy to be followed by all Office of Civilian Radioactive Waste Management (OCRWM) performance components. The OCRWM offices should observe these Guidelines in shaping and conducting public information activities.

  9. Guidelines for earthquake ground motion definition for the eastern United States

    International Nuclear Information System (INIS)

    Gwaltney, R.C.; Aramayo, G.A.; Williams, R.T.

    1985-01-01

    Guidelines for the determination of earthquake ground-motion definition for the eastern United States are established in this paper. Both far-field and near-field guidelines are given. The guidelines were based on an extensive review of the current procedures for specifying ground motion in the United States. Both empirical and theoretical procedures were used in establishing the guidelines because of the low seismicity in the eastern United States. Only a few large to great (M > 7.5) sized earthquakes have occurred in this region, no evidence of tectonic surface ruptures related to historic or Holocene earthquakes have been found, and no currently active plate boundaries of any kind are known in this region. Very little instrumented data has been gathered in the East. Theoretical procedures are proposed so that in regions of almost no data a reasonable level of seismic ground motion activity can be assumed. The guidelines are to be used to develop the Safe Shutdown Earthquake, SSE. A new procedure for establishing the Operating Basis Earthquake, OBE, is proposed, in particular for the eastern United States. The OBE would be developed using a probabilistic assessment of the geological conditions and the recurrence of seismic events at a site. These guidelines should be useful in development of seismic design requirements for future reactors. 17 refs., 2 figs., 1 tab

  10. Diabetes Technology-Continuous Subcutaneous Insulin Infusion Therapy and Continuous Glucose Monitoring in Adults: An Endocrine Society Clinical Practice Guideline.

    Science.gov (United States)

    Peters, Anne L; Ahmann, Andrew J; Battelino, Tadej; Evert, Alison; Hirsch, Irl B; Murad, M Hassan; Winter, William E; Wolpert, Howard

    2016-11-01

    To formulate clinical practice guidelines for the use of continuous glucose monitoring and continuous subcutaneous insulin infusion in adults with diabetes. The participants include an Endocrine Society-appointed Task Force of seven experts, a methodologist, and a medical writer. The American Association for Clinical Chemistry, the American Association of Diabetes Educators, and the European Society of Endocrinology co-sponsored this guideline. The Task Force developed this evidence-based guideline using the Grading of Recommendations, Assessment, Development, and Evaluation system to describe the strength of recommendations and the quality of evidence. The Task Force commissioned one systematic review and used the best available evidence from other published systematic reviews and individual studies. One group meeting, several conference calls, and e-mail communications enabled consensus. Committees and members of the Endocrine Society, the American Association for Clinical Chemistry, the American Association of Diabetes Educators, and the European Society of Endocrinology reviewed and commented on preliminary drafts of these guidelines. Continuous subcutaneous insulin infusion and continuous glucose monitoring have an important role in the treatment of diabetes. Data from randomized controlled trials are limited on the use of medical devices, but existing studies support the use of diabetes technology for a wide variety of indications. This guideline presents a review of the literature and practice recommendations for appropriate device use.

  11. The CARE guidelines: consensus-based clinical case report guideline development.

    Science.gov (United States)

    Gagnier, Joel J; Kienle, Gunver; Altman, Douglas G; Moher, David; Sox, Harold; Riley, David

    2014-01-01

    A case report is a narrative that describes, for medical, scientific, or educational purposes, a medical problem experienced by one or more patients. Case reports written without guidance from reporting standards are insufficiently rigorous to guide clinical practice or to inform clinical study design. Develop, disseminate, and implement systematic reporting guidelines for case reports. We used a three-phase consensus process consisting of (1) pre-meeting literature review and interviews to generate items for the reporting guidelines, (2) a face-to-face consensus meeting to draft the reporting guidelines, and (3) post-meeting feedback, review, and pilot testing, followed by finalization of the case report guidelines. This consensus process involved 27 participants and resulted in a 13-item checklist-a reporting guideline for case reports. The primary items of the checklist are title, key words, abstract, introduction, patient information, clinical findings, timeline, diagnostic assessment, therapeutic interventions, follow-up and outcomes, discussion, patient perspective, and informed consent. We believe the implementation of the CARE (CAse REport) guidelines by medical journals will improve the completeness and transparency of published case reports and that the systematic aggregation of information from case reports will inform clinical study design, provide early signals of effectiveness and harms, and improve healthcare delivery. Copyright © 2014 Reproduced with permission of Global Advances in Health and Medicine. Published by Elsevier Inc. All rights reserved.

  12. Summary guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Halsnaes, K.; Painuly, J.P.; Turkson, J.; Meyer, H.J.; Markandya, A.

    1999-09-01

    This document is a summary version of the methodological guidelines for climate change mitigation assessment developed as part of the Global Environment Facility (GEF) project Economics of Greenhouse Gas Limitations; Methodological Guidelines. The objectives of this project have been to develop a methodology, an implementing framework and a reporting system which countries can use in the construction of national climate change mitigation policies and in meeting their future reporting obligations under the FCCC. The methodological framework developed in the Methodological Guidelines covers key economic concepts, scenario building, modelling tools and common assumptions. It was used by several country studies included in the project. (au) 13 refs.

  13. Nonoperative management of blunt hepatic injury: an Eastern Association for the Surgery of Trauma practice management guideline.

    Science.gov (United States)

    Stassen, Nicole A; Bhullar, Indermeet; Cheng, Julius D; Crandall, Marie; Friese, Randall; Guillamondegui, Oscar; Jawa, Randeep; Maung, Adrian; Rohs, Thomas J; Sangosanya, Ayodele; Schuster, Kevin; Seamon, Mark; Tchorz, Kathryn M; Zarzuar, Ben L; Kerwin, Andrew

    2012-11-01

    During the last century, the management of blunt force trauma to the liver has changed from observation and expectant management in the early part of the 1900s to mainly operative intervention, to the current practice of selective operative and nonoperative management. These issues were first addressed by the Eastern Association for the Surgery of Trauma in the Practice Management Guidelines for Nonoperative Management of Blunt Injury to the Liver and Spleen published online in 2003. Since that time, a large volume of literature on these topics has been published requiring a reevaluation of the previous Eastern Association for the Surgery of Trauma guideline. The National Library of Medicine and the National Institutes of Health MEDLINE database were searched using PubMed (http://www.pubmed.gov). The search was designed to identify English-language citations published after 1996 (the last year included in the previous guideline) using the keywords liver injury and blunt abdominal trauma. One hundred seventy-six articles were reviewed, of which 94 were used to create the current practice management guideline for the selective nonoperative management of blunt hepatic injury. Most original hepatic guidelines remained valid and were incorporated into the greatly expanded current guidelines as appropriate. Nonoperative management of blunt hepatic injuries currently is the treatment modality of choice in hemodynamically stable patients, irrespective of the grade of injury or patient age. Nonoperative management of blunt hepatic injuries should only be considered in an environment that provides capabilities for monitoring, serial clinical evaluations, and an operating room available for urgent laparotomy. Patients presenting with hemodynamic instability and peritonitis still warrant emergent operative intervention. Intravenous contrast enhanced computed tomographic scan is the diagnostic modality of choice for evaluating blunt hepatic injuries. Repeated imaging should be

  14. The development of human factors technologies -The development of human factors experimental evaluation techniques-

    International Nuclear Information System (INIS)

    Shim, Bong Sik; Oh, In Suk; Cha, Kyung Hoh; Lee, Hyun Chul

    1995-07-01

    In this year, we studied the followings: 1) Development of operator mental workload evaluation techniques, 2) Development of a prototype for preliminary human factors experiment, 3) Suitability test of information display on a large scale display panel, 4) Development of guidelines for VDU-based control room design, 5) Development of integrated test facility (ITF). 6) Establishment of an eye tracking system, and we got the following results: 1) Mental workload evaluation techniques for MMI evaluation, 2) PROTOPEX (PROTOtype for preliminary human factors experiment) for preliminary human factors experiments, 3) Usage methods of APTEA (Analysis-Prototyping-Training-Experiment-Analysis) experiment design, 4) Design guidelines for human factors verification, 5) Detail design requirements and development plan of ITF, 6) Eye movement measurement system. 38 figs, 20 tabs, 54 refs. (Author)

  15. A preliminary investigation: the impact of microscopic condenser on depth of field in cytogenetic imaging

    Science.gov (United States)

    Ren, Liqiang; Qiu, Yuchen; Li, Zheng; Li, Yuhua; Zheng, Bin; Li, Shibo; Chen, Wei R.; Liu, Hong

    2013-02-01

    As one of the important components of optical microscopes, the condenser has a considerable impact on system performance, especially on the depth of field (DOF). DOF is a critical technical feature in cytogenetic imaging that may affect the efficiency and accuracy of clinical diagnosis. The purpose of this study is to investigate the influence of microscopic condenser on DOF using a prototype of transmitted optical microscope, based on objective and subjective evaluations. After the description of the relationship between condenser and objective lens and the theoretical analysis of the condenser impact on system numerical aperture and DOF, a standard resolution pattern and several cytogenetic samples are adopted to assess the condenser impact on DOF, respectively. The experimental results of these objective and subjective evaluations are in agreement with the theoretical analysis and show that, under the specific intermediate range of condenser numerical aperture ( NAcond ), the DOF value decreases with the increase of NAcond . Although the above qualitative results are obtained under the experimental conditions with a specific prototype system, the methods presented in this preliminary investigation could offer useful guidelines for optimizing operational parameters in cytogenetic imaging.

  16. Implementation dimension-6 operators into WHIZARD

    Energy Technology Data Exchange (ETDEWEB)

    Shim, So Young; Reuter, Juergen [DESY, Hamburg (Germany)

    2016-07-01

    To test physics beyond the Standard Model (SM) at the LHC in a model-independent way, we studied an Effective Field Theory (EFT) consisting of the SM with additional dimension-6 operators. Using a special basis for the operators, the GIMR basis, we implemented the complete set of dim-6 operators into the Monte Carlo Event Generator WHIZARD. Focusing on electroweak boson observables, we show preliminary results for LHC Run II at 13 TeV.

  17. Guidelines for Using Building Information Modeling for Energy Analysis of Buildings

    Directory of Open Access Journals (Sweden)

    Thomas Reeves

    2015-12-01

    Full Text Available Building energy modeling (BEM, a subset of building information modeling (BIM, integrates energy analysis into the design, construction, and operation and maintenance of buildings. As there are various existing BEM tools available, there is a need to evaluate the utility of these tools in various phases of the building lifecycle. The goal of this research was to develop guidelines for evaluation and selection of BEM tools to be used in particular building lifecycle phases. The objectives of this research were to: (1 Evaluate existing BEM tools; (2 Illustrate the application of the three BEM tools; (3 Re-evaluate the three BEM tools; and (4 Develop guidelines for evaluation, selection and application of BEM tools in the design, construction and operation/maintenance phases of buildings. Twelve BEM tools were initially evaluated using four criteria: interoperability, usability, available inputs, and available outputs. Each of the top three BEM tools selected based on this initial evaluation was used in a case study to simulate and evaluate energy usage, daylighting performance, and natural ventilation for two academic buildings (LEED-certified and non-LEED-certified. The results of the case study were used to re-evaluate the three BEM tools using the initial criteria with addition of the two new criteria (speed and accuracy, and to develop guidelines for evaluating and selecting BEM tools to analyze building energy performance. The major contribution of this research is the development of these guidelines that can help potential BEM users to identify the most appropriate BEM tool for application in particular building lifecycle phases.

  18. Reconciling pairs of concurrently used clinical practice guidelines using Constraint Logic Programming.

    Science.gov (United States)

    Wilk, Szymon; Michalowski, Martin; Michalowski, Wojtek; Hing, Marisela Mainegra; Farion, Ken

    2011-01-01

    This paper describes a new methodological approach to reconciling adverse and contradictory activities (called points of contention) occurring when a patient is managed according to two or more concurrently used clinical practice guidelines (CPGs). The need to address these inconsistencies occurs when a patient with more than one disease, each of which is a comorbid condition, has to be managed according to different treatment regimens. We propose an automatic procedure that constructs a mathematical guideline model using the Constraint Logic Programming (CLP) methodology, uses this model to identify and mitigate encountered points of contention, and revises the considered CPGs accordingly. The proposed procedure is used as an alerting mechanism and coupled with a guideline execution engine warns the physician about potential problems with the concurrent application of two or more guidelines. We illustrate the operation of our procedure in a clinical scenario describing simultaneous use of CPGs for duodenal ulcer and transient ischemic attack.

  19. Monitoring and evaluation of Blyth Offshore wind farm: Health and Safety guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Pepper, L

    2002-07-01

    Experiences during the construction, operation and maintenance of the wind farm off the coast of Blyth in Northumberland are used to assess the practicality of implementing existing draft British Wind Energy Association (BWEA) guidelines. These best practice guidelines, which were drawn up in consultation with the Health and Safety Executive (HSE) offer advice on health and safety issues specific to the wind industry in the UK. The guidelines are intended to cover both onshore and offshore sites; common advice is followed by advice specific to offshore sites. The Blyth Offshore project, the first offshore wind farm in the UK, features two 2 MW turbines installed on a submerged rocky outcrop about 1 km from the coast in a depth of about 6 m at low tide and a tidal range of about 5 m. The report concluded that, from the experience at Blyth, the draft guidelines will provide a useful tool for those involved in all stages of a wind farm project.

  20. Pre-operative fasting: a nationwide survey of German anaesthesia departments.

    Science.gov (United States)

    Breuer, J-P; Bosse, G; Seifert, S; Prochnow, L; Martin, J; Schleppers, A; Geldner, G; Soreide, E; Spies, C

    2010-03-01

    Shorter pre-operative fasting improves clinical outcome without an increased risk. Since October 2004, German Anaesthesiology Societies have officially recommended a fast of 2 h for clear fluids and 6 h for solid food before elective surgery. We conducted a nationwide survey to evaluate the current clinical practice in Germany. Between July 2006 and January 2007, standardized questionnaires were mailed to 3751 Anaesthesiology Society members in leading positions requesting anonymous response. The overall response rate was 66% (n=2418). Of those, 2148 (92%) claimed familiarity with the new guidelines. About a third (n=806, 34%) reported full adherence to the new recommendations, whereas 1043 (45%) reported an eased fasting practice. Traditional Nil per os after midnight was still recommended by 157 (7%). Commonest reasons reported for adopting the new guidelines were: 'improved pre-operative comfort' (84%), and 'increased patient satisfaction' (83%); reasons against were: 'low flexibility in operation room management' (19%), and 'increased risk of aspiration' (13%). Despite the apparent understanding of the benefits from reduced pre-operative fasting, full implementation of the guidelines remains poor in German anaesthesiology departments.

  1. Global Imaging referral guidelines

    International Nuclear Information System (INIS)

    Kawooya, M.; Perez, M.; Lau, L.; Reeed, M.

    2010-01-01

    The medical imaging specialists called for global referral guidelines which would be made available to referring doctors. These referral guidelines should be:- Applicable in different health care settings, including resource-poor settings; Inclusive in terms of the range of clinical conditions; User-friendly and accessible (format/media); Acceptable to stakeholders, in particular to the referrers as the main target audience. To conceive evidence-based medicine as an integration of best research evidence with clinical expertise and patient values. The Direct recipients of the Referral Guidelines would be:- Referrers: general practitioners / family doctors; paediatricians; emergency department doctors; other specialists and health workers. Providers (medical imaging practitioners): radiologists; nuclear medicine physicians; radiographers; other appropriately qualified practitioners providing diagnostic imaging services. For the Referral Guidelines to be effective there need to be: Credibility evidence-based Practicality end user involvement Context local resources, disease profiles Endorsement, opinion leaders Implementation- policy, education, CPOE - Monitoring of the use clinical audit, report feedback. The aim of the Referral Guidelines Project was to: Produce global referral guidelines that are evidence-based, cost effective and appropriate for the local setting, and include consideration of available equipment and expertise (RGWG; SIGs); Include supporting information about radiation doses, potential risks, protection of children and pregnant women (introductory chapter); Facilitate the implementation of the guidelines through guidance and tools (e.g. implementation guides, checklists, capacity building tools, guides on stakeholders engagement, audit support criteria); Conduct pilot testing in different clinical settings from each of the six WHO regions; Promote the inclusion of the referral guidelines in the curricula of medical schools; Develop and implement

  2. Preliminary safety assessment study for the conceptual design of a repository in tuff at Yucca Mountain

    International Nuclear Information System (INIS)

    Jackson, J.L.; Gram, H.F.; Hong, K.J.; Ng, H.S.; Pendergrass, A.M.

    1984-12-01

    Preliminary estimates of the upper bounds on postulated worst-case radiological releases resulting from possible accidents during the operating period of a prospective repository in tuff at Yucca Mountain are presented. Possible disrupting events are screened to identify the accidents of greatest potential consequence. The radiological dose commitments for the general public and repository personnel are estimated for postulated releases caused by natural phenomena, man-made events, and operational accidents. All postulated worst-case releases result in doses to the public that are lower than the 0.5-rem, whole-body dose-per-accident limit set by the Nuclear Regulatory Commission (NRC) in 10 CFR 60. Doses to repository personnel are within the NRC's 5.0-rem/yr occupational exposure limit set in 10 CFR 20 for normal operations. Doses are within this limit for all accidents except the transportation accident and fire in a drift. A preliminary risk assessment has also been performed. Based on this preliminary safety study, the proposed site boundaries and design criteria routinely used in constructing nuclear facilities appear to be adequate to protect the safety of the general public during the operating phase of the repository

  3. Developing clinical practice guidelines for Chinese herbal treatment of polycystic ovary syndrome: A mixed-methods modified Delphi study.

    Science.gov (United States)

    Lai, Lily; Flower, Andrew; Moore, Michael; Lewith, George

    2015-06-01

    Preliminary evidence suggests Chinese herbal medicine (CHM) could be a viable treatment option for polycystic ovary syndrome (PCOS). Prior to conducting a clinical trial it is important to consider the characteristics of good clinical practice. This study aims to use professional consensus to establish good clinical practice guidelines for the CHM treatment of PCOS. CHM practitioners participated in a mixed-methods modified Delphi study involving three rounds of structured group communication. Round 1 involved qualitative interviews with practitioners to generate statements regarding good clinical practice. In round 2, these statements were distributed online to the same practitioners to rate their agreement using a 7-point Likert scale, where group consensus was defined as a median rating of ≥5. Statements reaching consensus were accepted for consideration onto the guideline whilst those not reaching consensus were re-distributed for consideration in round 3. Statements presented in the guidelines were graded from A (strong consensus) to D (no consensus) determined by median score and interquartile range. 11 CHM practitioners in the UK were recruited. After three Delphi rounds, 91 statement items in total had been considered, of which 89 (97.8%) reached consensus and 2 (2.2%) did not. The concluding set of guidelines consists of 85 items representing key features of CHM prescribing for PCOS. These guidelines can be viewed as an initial framework that captures fundamental principles of good clinical practice for CHM. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Guidelines for preparing criticality safety evaluations at Department of Energy non-reactor nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-09-01

    This Department of Energy (DOE) is approved for use by all components of DOE. It contains guidelines that should be followed when preparing Criticality Safety Evaluations that will be used to demonstrate the safety of operations performed at DOE Non-Reactor Nuclear Facilities. Adherence with these guidelines will provide consistency and uniformity in Criticality Safety Evaluations (CSEs) across the complex and will document compliance with DOE Order 5480.24 requirements as they pertain to CSEs.

  5. Guidelines for preparing criticality safety evaluations at Department of Energy non-reactor nuclear facilities

    International Nuclear Information System (INIS)

    1998-09-01

    This Department of Energy (DOE) is approved for use by all components of DOE. It contains guidelines that should be followed when preparing Criticality Safety Evaluations that will be used to demonstrate the safety of operations performed at DOE Non-Reactor Nuclear Facilities. Adherence with these guidelines will provide consistency and uniformity in Criticality Safety Evaluations (CSEs) across the complex and will document compliance with DOE Order 5480.24 requirements as they pertain to CSEs

  6. An interactive simulation-based education system for BWR emergency, procedure guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Tanikawa, Naoshi; Shida, Touichi [Hitachi Ltd (Japan). Hitachi Works; Ujita, Hiroshi; Yokota, Takeshi; Kato, Kanji [Hitachi Ltd, (Japan). Energy Research Lab.

    1994-12-31

    When applying EPGs (Emergency Procedure Guidelines), an operator decides the operational procedure by predicting the change of parameters from the plant status, because EPGs are described in a symptom style for emergency conditions. Technical knowledge of the plant behavior and its operation are necessary for operator to understand the EPGs. An interactive simulation-based education system, EPG-ICAI (Intelligent Computer Assisted Instruction), has been developed for BWR plant operators to acquire the knowledge of EPGs. EPG-ICAI is designed to realize an effective education by the step-by-step study by using an interactive real time simulator and an individual education by applying an intelligent tutoring function. (orig.) (2 refs., 7 figs., 1 tab.).

  7. An interactive simulation-based education system for BWR emergency, procedure guidelines

    International Nuclear Information System (INIS)

    Tanikawa, Naoshi; Shida, Touichi; Ujita, Hiroshi; Yokota, Takeshi; Kato, Kanji

    1994-01-01

    When applying EPGs (Emergency Procedure Guidelines), an operator decides the operational procedure by predicting the change of parameters from the plant status, because EPGs are described in a symptom style for emergency conditions. Technical knowledge of the plant behavior and its operation are necessary for operator to understand the EPGs. An interactive simulation-based education system, EPG-ICAI (Intelligent Computer Assisted Instruction), has been developed for BWR plant operators to acquire the knowledge of EPGs. EPG-ICAI is designed to realize an effective education by the step-by-step study by using an interactive real time simulator and an individual education by applying an intelligent tutoring function. (orig.) (2 refs., 7 figs., 1 tab.)

  8. Final guidelines for an Environmental Impact Statement on the proposed construction and operation of a replacement nuclear research reactor at the Lucas Heights Science and Technology Centre

    International Nuclear Information System (INIS)

    1998-01-01

    These guidelines are based on the requirements of paragraphs 4.1 and 4.3 of the Administrative Procedures under the Commonwealth Environment Protection (Impact of Proposals) Act 1974 (EPIP Act).The Australian Nuclear Science and Technology Organisation (ANSTO) has been designated as proponent under the EPIP Act in relation to the proposed replacement nuclear research reactor at the Lucas Heights Science and Technology Centre (LHSTC). The term 'environment' refers to all aspects of the surroundings of human beings, whether affecting human beings as individuals or in social groupings. It includes the natural environment, the built environment, and social aspects of our surroundings. The definition covers such factors as air, water, soils, flora,fauna, buildings, roads, employment, hazards and risks, and safety. As set out in the guidelines, the scope of this assessment shall encompass those issues and alternatives directly related to the construction and operation of a replacement nuclear research reactor at the LHSTC. The EIS will need to make clear the site selection criteria used, and the basis, in assessing Lucas Heights as being suitable for a new reactor. While the EIS will address all aspects of the construction and operation of a replacement nuclear research reactor, it will not address issues associated with the treatment of spent nuclear fuel rods from the existing High Flux Australian Reactor (HIFAR facility). The EIS will also address issues associated with the eventual decommissioning of the proposed replacement reactor, and eventual decommissioning of the existing HIFAR facility

  9. Program management aid for redundancy selection and operational guidelines

    Science.gov (United States)

    Hodge, P. W.; Davis, W. L.; Frumkin, B.

    1972-01-01

    Although this criterion was developed specifically for use on the shuttle program, it has application to many other multi-missions programs (i.e. aircraft or mechanisms). The methodology employed is directly applicable even if the tools (nomographs and equations) are for mission peculiar cases. The redundancy selection criterion was developed to insure that both the design and operational cost impacts (life cycle costs) were considered in the selection of the quantity of operational redundancy. These tools were developed as aids in expediting the decision process and not intended as the automatic decision maker. This approach to redundancy selection is unique in that it enables a pseudo systems analysis to be performed on an equipment basis without waiting for all designs to be hardened.

  10. Preliminary assessment of valve IST effectiveness

    International Nuclear Information System (INIS)

    Grove, E.; DiBiasio, A.; Carbonaro, J.

    1994-01-01

    A preliminary review of inservice testing effectiveness for Code Class 1,2, and 3 valves at nuclear power plants was performed. These requirements are specified by the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section XI, and the Operations and Maintenance Standard. The Institute of Nuclear Power Operations Nuclear Plant Reliability Data System (NPRDS) database was used to provide failure reports for these components for 1988 to 1992. This time period coincides with the issuance of Generic Letter 89-04, which resulted in a more consistent application of the requirements by the licensees. For this time period, 8,593 valve failures were identified. From the review of the NPRDS database, the primary failure causes and failure modes for motor-operated valves (MOV), air-operated valves (AOV), and check valves (CV) were identified. Solenoid-operated valves were not reviewed in this study. Plant testing programs were effective in identifying approximately 60% of the CV failures, 46% of the AOV failures, and 44% of the MOV failures

  11. Guidelines for the Interpretation of Results of Microbiological Testing of Ready-to-Eat Foods Placed on the Market (Revision 2)

    OpenAIRE

    Food Safety Authority of Ireland

    2016-01-01

    This document provides guideline microbiological limits for ready-to-eat foods placed on the market. These guideline limits can be used if legal microbiological criteria (Appendix 1) do not exist for a particular combination of food and microorganism. This Guidance Note is intended to be used by: • Food business operators • Enforcement officers, and • Laboratories performing microbiological testing on ready-to-eat foods Food business operators may also use the limits prese...

  12. Online advertising and marketing claims by providers of proton beam therapy: are they guideline-based?

    Science.gov (United States)

    Corkum, Mark T; Liu, Wei; Palma, David A; Bauman, Glenn S; Dinniwell, Robert E; Warner, Andrew; Mishra, Mark V; Louie, Alexander V

    2018-03-15

    Cancer patients frequently search the Internet for treatment options, and hospital websites are seen as reliable sources of knowledge. Guidelines support the use of proton radiotherapy in specific disease sites or on clinical trials. This study aims to evaluate direct-to-consumer advertising content and claims made by proton therapy centre (PTC) websites worldwide. Operational PTC websites in English were identified through the Particle Therapy Co-Operative Group website. Data abstraction of website content was performed independently by two investigators. Eight international guidelines were consulted to determine guideline-based indications for proton radiotherapy. Univariate and multivariate logistic regression models were used to determine the characteristics of PTC websites that indicated proton radiotherapy offered greater disease control or cure rates. Forty-eight PTCs with 46 English websites were identified. 60·9% of PTC websites claimed proton therapy provided improved disease control or cure. U.S. websites listed more indications than international websites (15·5 ± 5·4 vs. 10·4 ± 5·8, p = 0·004). The most common disease sites advertised were prostate (87·0%), head and neck (87·0%) and pediatrics (82·6%), all of which were indicated in least one international guideline. Several disease sites advertised were not present in any consensus guidelines, including pancreatobiliary (52·2%), breast (50·0%), and esophageal (43·5%) cancers. Multivariate analysis found increasing number of disease sites and claiming their centre was a local or regional leader in proton radiotherapy was associated with indicating proton radiotherapy offers greater disease control or cure. Information from PTC websites often differs from recommendations found in international consensus guidelines. As online marketing information may have significant influence on patient decision-making, alignment of such information with accepted guidelines and consensus

  13. Preliminary format design guidelines

    DEFF Research Database (Denmark)

    Tosello, Guido; Calaon, Matteo; Nørregaard, J.

    2013-01-01

    The strategic research centre PolyNano aims at becoming the Danish competence centre for production-ready fabrication of polymer, nano-scale lab-on-a-chip (LoC) devices. In order to provide a competitive edge for Danish biotech companies launching LoC products by removal of the technology barrier...

  14. Preliminary Hazard Analysis applied to Uranium Hexafluoride - UF6 production plant

    International Nuclear Information System (INIS)

    Tomzhinsky, David; Bichmacher, Ricardo; Braganca Junior, Alvaro; Peixoto, Orpet Jose

    1996-01-01

    The purpose of this paper is to present the results of the Preliminary hazard Analysis applied to the UF 6 Production Process, which is part of the UF 6 Conversion Plant. The Conversion Plant has designed to produce a high purified UF 6 in accordance with the nuclear grade standards. This Preliminary Hazard Analysis is the first step in the Risk Management Studies, which are under current development. The analysis evaluated the impact originated from the production process in the plant operators, members of public, equipment, systems and installations as well as the environment. (author)

  15. MAR flow mapping of Analytical Chemistry Operations (Preliminary Report)

    International Nuclear Information System (INIS)

    Barr, Mary E.; Farish, Thomas J.

    2012-01-01

    The recently released Supplemental Directive, NA-1 SD 1027, updates the radionuclide threshold values in DOE-STD-1027-92 CN1 to reflect the use of modern parameters for dose conversion factors and breathing rates. The directive also corrects several arithmetic errors within the original standard. The result is a roughly four-fold increase in the amount of weapons-grade nuclear material allowed within a designated radiological facility. Radiological laboratory space within the recently constructed Radiological Laboratory Office and Utility Building (RLUOB) is slated to house selected analytical chemistry support activities in addition to small-scale actinide R and D activities. RLUOB is within the same facility operations envelope as TA-55. Consolidation of analytical chemistry activities to RLUOB and PF-4 offers operational efficiency improvements relative to the current pre-CMRR plans of dividing these activities between RLUOB, PF-4, and CMR. RLUOB is considered a Radiological Facility under STD-1027 - 'Facilities that do not meet or exceed Category 3 threshold criteria but still possess some amount of radioactive material may be considered Radiological Facilities.' The supplemental directive essentially increases the allowable material-at-risk (MAR) within radiological facilities from 8.4 g to 38.6 g for 239 Pu. This increase in allowable MAR provides a unique opportunity to establish additional analytical chemistry support functions in RLUOB without negatively impacting either R and D activities or facility operations. Individual radiological facilities are tasked to determine MAR limits (up to the Category 3 thresholds) appropriate to their operational conditions. This study presents parameters that impact establishing MAR limits for RLUOB and an assessment of how various analytical chemistry support functions could operate within the established MAR limits.

  16. Connecticut Transit (CTTRANSIT) Fuel Cell Transit Bus: Preliminary Evaluation Results

    Energy Technology Data Exchange (ETDEWEB)

    Chandler, K.; Eudy, L.

    2008-10-01

    This report provides preliminary results from a National Renewable Energy Laboratory evaluation of a protoptye fuel cell transit bus operating at Connecticut Transit in Hartford. Included are descriptions of the planned fuel cell bus demonstration and equipment; early results and agency experience are also provided.

  17. Preliminary results of neutron production in Sahand plasma focus device

    International Nuclear Information System (INIS)

    Siahpoush, V.; Mohammadi, M.A.; Khorram, S.; Shabani, I.; Borhanian, J.; Ashrafi, S.; Naghshara, H.; Moslehi-Fard, M.; Sobhanian, S.

    2004-01-01

    We report in this paper the preliminary results of neutron generation during fusion reaction in deuterium in the Sahand Filipov type plasma focus, recently installed and put in operation at Tabriz University. The special calibration procedure for neutron detection system, using activation method is described

  18. Evaluation of a protocol for the non-operative management of perforated peptic ulcer.

    Science.gov (United States)

    Marshall, C; Ramaswamy, P; Bergin, F G; Rosenberg, I L; Leaper, D J

    1999-01-01

    The non-operative management of perforated peptic ulcer has previously been shown to be both safe and effective although it remains controversial. A protocol for non-operative management was set up in this hospital in 1989. Adherence to the guidelines in the protocol has been audited over a 6-year period with a review of outcome. The case-notes of patients with a diagnosis of perforated peptic ulcer were reviewed. Twelve guidelines from the protocol were selected for evaluation of compliance to the protocol. Forty-nine patients underwent non-operative treatment initially. Eight patients failed to respond and underwent operation. Complications included abscess formation (seven patients), renal failure (one), gastric ileus (one), chest infection (two), and cardiac failure and stroke (one). Four deaths occurred in this group. Adherence to certain protocol guidelines was poor, notably those concerning prevention of thromboembolism, use of antibiotics, use of contrast examination to confirm the diagnosis and referral for follow-up endoscopy. Two gastric cancers were detected on subsequent endoscopy. This experience demonstrates that non-operative treatment can be used successfully in a general hospital. Adherence to protocol guidelines was found to be variable and the protocol has therefore been simplified. This study highlights the need for an accurate diagnosis and the importance of follow-up endoscopy.

  19. The healing arts radiation protection guidelines

    International Nuclear Information System (INIS)

    Yaffe, M.

    1987-06-01

    The objective of these guidelines is to help the health professional render the risks associated with diagnostic radiation as low as reasonably achievable. The guidelines contain advice and recommendations, but no mandatory requirements. They assist radiation protection officers in establishing and maintaining a Quality Assurance Program and in carrying out other duties required by the Healing Arts Radiation Protection Act; assist staff to comply with the X-ray Safety Code in a way that will raise the standards of x-ray diagnosis and patient safety; address the relationship between the radiation exposure of the patient and the quality of the image; address the problem of protecting the patient in x-ray examinations; summarize x-ray safety problems from the point of view of the operator and other staff; indicate what remedial measures can be taken; define the quality assurance needs of x-ray users; and encourage the users of x-rays for diagnostic purposes to go beyond the scope of the Act and comply with the ALARA principle

  20. Operational Planning Considerations for the Use of Riot Control Agents in Military Operations Other Than War

    National Research Council Canada - National Science Library

    Hoppe, Jeffrey J

    2005-01-01

    .... While operational planners must stay within the boundaries outlined by international law and current policies, the principles of MOOTW are useful guidelines for exposing political, cultural, and social issues that are vital to mission accomplishment.

  1. Design patterns for modelling guidelines

    NARCIS (Netherlands)

    Serban, Radu; Ten Teije, Annette; Marcos, Mar; Polo-Conde, Cristina; Rosenbrand, Kitty C J G M; Wittenberg, Jolanda; van Croonenborg, Joyce

    2005-01-01

    It is by now widely accepted that medical guidelines can help to significantly improve the quality of medical care. Unfortunately, constructing the required medical guidelines is a very labour intensive and costly process. The cost of guideline construction would decrease if guidelines could be

  2. 7 CFR 622.5 - Guidelines.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Guidelines. 622.5 Section 622.5 Agriculture... AGRICULTURE WATER RESOURCES WATERSHED PROJECTS General § 622.5 Guidelines. Guidelines for carrying out... Environmental Principles and Guidelines for Water and Related Land Resources Implementation Studies issued by...

  3. Cw operation of the FMIT RFQ accelerator

    International Nuclear Information System (INIS)

    Cornelius, W.D.

    1985-01-01

    Recently, we have achieved reliable cw operation of the Fusion Materials Irradiation Test (FMIT) radio-frequency quadrupole (RFQ) accelerator. In addition to the operational experiences in achieving this status, some of the modifications of the vacuum system, cooling system, and rf structure are discussed. Preliminary beam-characterization results are presented. 10 refs., 8 figs

  4. Stress and Psychological Support in Modern Military Operations (Stress et aide psychologique dans les operations militaires modernes)

    National Research Council Canada - National Science Library

    2008-01-01

    NATO Task Group HFM-081/RTG on "Stress and Psychological Support in Modern Military Operations" has produced, in the form of a Military Leaders Guide, a series of guidelines for psychological support...

  5. Implementing national nuclear safety plan at the preliminary stage of nuclear power project development

    International Nuclear Information System (INIS)

    Xue Yabin; Cui Shaozhang; Pan Fengguo; Zhang Lizhen; Shi Yonggang

    2014-01-01

    This study discusses the importance of nuclear power project design and engineering methods at the preliminary stage of its development on nuclear power plant's operational safety from the professional view. Specifically, we share our understanding of national nuclear safety plan's requirement on new reactor accident probability, technology, site selection, as well as building and improving nuclear safety culture and strengthening public participation, with a focus on plan's implications on preliminary stage of nuclear power project development. Last, we introduce China Huaneng Group's work on nuclear power project preliminary development and the experience accumulated during the process. By analyzing the siting philosophy of nuclear power plant and the necessity of building nuclear safety culture at the preliminary stage of nuclear power project development, this study explicates how to fully implement the nuclear safety plan's requirements at the preliminary stage of nuclear power project development. (authors)

  6. Engineering design guidelines for nuclear criticality safety

    International Nuclear Information System (INIS)

    Waltz, W.R.

    1988-08-01

    This document provides general engineering design guidelines specific to nuclear criticality safety for a facility where the potential for a criticality accident exists. The guide is applicable to the design of new SRP/SRL facilities and to major modifications Of existing facilities. The document is intended an: A guide for persons actively engaged in the design process. A resource document for persons charged with design review for adequacy relative to criticality safety. A resource document for facility operating personnel. The guide defines six basic criticality safety design objectives and provides information to assist in accomplishing each objective. The guide in intended to supplement the design requirements relating to criticality safety contained in applicable Department of Energy (DOE) documents. The scope of the guide is limited to engineering design guidelines associated with criticality safety and does not include other areas of the design process, such as: criticality safety analytical methods and modeling, nor requirements for control of the design process

  7. Guideline on radiation protection requirements for ionizing radiation shielding in nuclear power plants

    International Nuclear Information System (INIS)

    1988-01-01

    The guideline which entered into force on 1 May 1988 stipulates the radiation protection requirements for shielding against ionizing radiation to be met in the design, construction, commissioning, operation, and decommissioning of nuclear power plants

  8. Preliminary analyses of AP600 using RELAP5

    International Nuclear Information System (INIS)

    Modro, S.M.; Beelman, R.J.; Fisher, J.E.

    1991-01-01

    This paper presents results of preliminary analyses of the proposed Westinghouse Electric Corporation AP600 design. AP600 is a two loop, 600 MW (e) pressurized water reactor (PWR) arranged in a two hot leg, four cold leg nuclear steam supply system (NSSS) configuration. In contrast to the present generation of PWRs it is equipped with passive emergency core coolant (ECC) systems. Also, the containment and the safety systems of the AP600 interact with the reactor coolant system and each other in a more integral fashion than present day PWRs. The containment in this design is the ultimate heat sink for removal of decay heat to the environment. Idaho National Engineering Laboratory (INEL) has studied applicability of the RELAP5 code to AP600 safety analysis and has developed a model of the AP600 for the Nuclear Regulatory Commission. The model incorporates integral modeling of the containment, NSSS and passive safety systems. Best available preliminary design data were used. Nodalization sensitivity studies were conducted to gain experience in modeling of systems and conditions which are beyond the applicability of previously established RELAP5 modeling guidelines or experience. Exploratory analyses were then undertaken to investigate AP600 system response during postulated accident conditions. Four small break LOCA calculations and two large break LOCA calculations were conducted

  9. Development of cancer treatment guidelines

    African Journals Online (AJOL)

    Krystyna Kiel

    2011-05-26

    May 26, 2011 ... KEYWORDS. Cancer;. Therapy;. Guidelines. Contents. 1. Why develop guidelines? ... Widely available guideline resources in cancer care. ... The use of guidelines in medicine has a long history. Many .... She has a negative family history. ... The patient has 1 cm grade 3 infiltrating ductal carcinoma.

  10. 28 CFR 42.306 - Guidelines.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Guidelines. 42.306 Section 42.306... PROCEDURES Equal Employment Opportunity Program Guidelines § 42.306 Guidelines. (a) Recipient agencies are... guidelines under their equal employment opportunity program which will correct, in a timely manner, any...

  11. 28 CFR 42.404 - Guidelines.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Guidelines. 42.404 Section 42.404... Guidelines. (a) Federal agencies shall publish title VI guidelines for each type of program to which they extend financial assistance, where such guidelines would be appropriate to provide detailed information...

  12. Safe commuting factors from existing guidelines in Malaysia: a review for the construction sector

    Science.gov (United States)

    Sukor, E. S. A.; Suratkon, A.; Mohammad, H.; Yaman, S. K.

    2018-04-01

    The construction industry is a very active and dynamic industry, which proceeding as one of the significant industry that contributing to the country’s economy. Unfortunately, the construction industry has also earned the reputation of being the riskiest industry because of the higher rates of accidents and fatalities. Nevertheless, overwhelming focus by many on the accident in the workplace has shaded the alarming issue of the construction-related commuting accident. As reported by the Malaysia’s Social Security Organisation (SOCSO) in 2016, the number of commuting accidents and the compensations paid is increasing each year, and it is including the construction sector. Aware of the importance of safe commuting, several Malaysian agencies have developed their guidelines specifically for the improvement of such issue. Regrettably, the number of guidelines published does not exemplify the improvement of such issue when the number of commuting accidents is on the rise, especially for the construction sector. Therefore, this preliminary research was conducted to identify the safe commuting factors from the existing guidelines through manual document analysis. The finding shows that there are four (4) major categories namely; (1) driver/human factor, (2) vehicle factor, (3) environment factor, and (4) others. Hence, the research posits for subsequent exploration to ensure strategic implementation of those factors that will benefit the Malaysia’s construction sector.

  13. A systematic literature search on psychological first aid: lack of evidence to develop guidelines.

    Science.gov (United States)

    Dieltjens, Tessa; Moonens, Inge; Van Praet, Koen; De Buck, Emmy; Vandekerckhove, Philippe

    2014-01-01

    Providing psychological first aid (PFA) is generally considered to be an important element in preliminary care of disaster victims. Using the best available scientific basis for courses and educational materials, the Belgian Red Cross-Flanders wants to ensure that its volunteers are trained in the best way possible. To identify effective PFA practices, by systematically reviewing the evidence in existing guidelines, systematic reviews and individual studies. Systematic literature searches in five bibliographic databases (MEDLINE, PsycINFO, The Cochrane Library, PILOTS and G-I-N) were conducted from inception to July 2013. Five practice guidelines were included which were found to vary in the development process (AGREE II score 20-53%) and evidence base used. None of them provides solid evidence concerning the effectiveness of PFA practices. Additionally, two systematic reviews of PFA were found, both noting a lack of studies on PFA. A complementary search for individual studies, using a more sensitive search strategy, identified 11 237 references of which 102 were included for further full-text examination, none of which ultimately provides solid evidence concerning the effectiveness of PFA practices. The scientific literature on psychological first aid available to date, does not provide any evidence about the effectiveness of PFA interventions. Currently it is impossible to make evidence-based guidelines about which practices in psychosocial support are most effective to help disaster and trauma victims.

  14. A systematic literature search on psychological first aid: lack of evidence to develop guidelines.

    Directory of Open Access Journals (Sweden)

    Tessa Dieltjens

    Full Text Available Providing psychological first aid (PFA is generally considered to be an important element in preliminary care of disaster victims. Using the best available scientific basis for courses and educational materials, the Belgian Red Cross-Flanders wants to ensure that its volunteers are trained in the best way possible.To identify effective PFA practices, by systematically reviewing the evidence in existing guidelines, systematic reviews and individual studies.Systematic literature searches in five bibliographic databases (MEDLINE, PsycINFO, The Cochrane Library, PILOTS and G-I-N were conducted from inception to July 2013.Five practice guidelines were included which were found to vary in the development process (AGREE II score 20-53% and evidence base used. None of them provides solid evidence concerning the effectiveness of PFA practices. Additionally, two systematic reviews of PFA were found, both noting a lack of studies on PFA. A complementary search for individual studies, using a more sensitive search strategy, identified 11 237 references of which 102 were included for further full-text examination, none of which ultimately provides solid evidence concerning the effectiveness of PFA practices.The scientific literature on psychological first aid available to date, does not provide any evidence about the effectiveness of PFA interventions. Currently it is impossible to make evidence-based guidelines about which practices in psychosocial support are most effective to help disaster and trauma victims.

  15. Variability in Antibiotic Regimens for Surgical Necrotizing Enterocolitis Highlights the Need for New Guidelines.

    Science.gov (United States)

    Blackwood, Brian P; Hunter, Catherine J; Grabowski, Julia

    Necrotizing enterocolitis or NEC is the most common gastrointestinal emergency in the newborn. The etiology of NEC remains unknown, and treatment consists of antibiotic therapy and supportive care with the addition of surgical intervention as necessary. Unlike most surgical diseases, clear guidelines for the type and duration of peri-operative antibiotic therapy have not been established. Our aim was to review the antibiotic regimen(s) applied to surgical patients with NEC within a single neonatal intensive care unit (NICU) and to evaluate outcomes and help develop guidelines for antibiotic administration in this patient population. A single-center retrospective review was performed of all patients who underwent surgical intervention for NEC from August 1, 2005 through August 1, 2015. Relevant data were extracted including gestational age, age at diagnosis, gender, pre-operative antibiotic treatment, post-operative antibiotic treatment, development of stricture, and mortality. Patients were excluded if there was incomplete data documentation. A total of 90 patients were identified who met inclusion criteria. There were 56 male patients and 34 female patients. The average gestational age was 30 5/7 wks and average age of diagnosis 16.7 d. A total of 22 different pre-operative antibiotic regimens were identified with an average duration of 10.6 d. The most common pre-operative regimen was ampicillin, gentamicin, and metronidazole for 14 d. A total of 15 different post-operative antibiotic regimens were identified with an average duration of 6.6 d. The most common post-operative regimen was ampicillin, gentamicin, and metronidazole for two days. There were 26 strictures and 15 deaths. No regimen or duration proved superior. We found that there is a high degree of variability in the antibiotic regimen for the treatment of NEC, even within a single NICU, with no regimen appearing superior over another. As data emerge that demonstrate the adverse effects of

  16. Visitor's Computer Guidelines | CTIO

    Science.gov (United States)

    Visitor's Computer Guidelines Network Connection Request Instruments Instruments by Telescope IR Instruments Guidelines Library Facilities Outreach NOAO-S EPO Program team Art of Darkness Image Gallery EPO/CADIAS ‹› You are here CTIO Home » Astronomers » Visitor's Computer Guidelines Visitor's Computer

  17. Workshop presentation: research guidelines for Construction Management

    Directory of Open Access Journals (Sweden)

    Marco Alvise Bragadin

    2013-10-01

    Full Text Available Nowadays the European economic system challenges the construction sector to take part to industrial recovery of western countries. In co-operation with the Construction Production research group of the Tampere University of of research about construction management tools and methods were detected. Research guidelines: 1 Construction management: tools and methods to manage construction projects 2 environmental impact of construction projects 3 construction management and safety 4 project procurement 5 construction management for major public works & complex projects

  18. Nurses' experiences of guideline implementation

    DEFF Research Database (Denmark)

    Alanen, Seija; Välimäki, Marita; Kaila, Minna

    2009-01-01

    AIMS: The aim of the study was to address the following questions: What kind of experiences do primary care nurses have of guideline implementation? What do nurses think are the most important factors affecting the adoption of guidelines? BACKGROUND: The implementation of clinical guidelines seems...... to be dependent on multiple context-specific factors. This study sets out to explore the experiences of primary care nurses concerning guideline implementation. DESIGN: Qualitative interview. METHODS: Data were generated by four focus group interviews involving nurses working in out-patient services in primary...... to nurses, (iii) factors related to the anticipated consequences and (iv) factors related to the patient group. Nurses' awareness and acceptance of guidelines and the anticipated positive consequences facilitate the implementation of guidelines. Organisational support, especially the adapting of guidelines...

  19. SU-E-P-43: A Knowledge Based Approach to Guidelines for Software Safety

    International Nuclear Information System (INIS)

    Salomons, G; Kelly, D

    2015-01-01

    Purpose: In the fall of 2012, a survey was distributed to medical physicists across Canada. The survey asked the respondents to comment on various aspects of software development and use in their clinic. The survey revealed that most centers employ locally produced (in-house) software of some kind. The respondents also indicated an interest in having software guidelines, but cautioned that the realities of cancer clinics include variations, that preclude a simple solution. Traditional guidelines typically involve periodically repeating a set of prescribed tests with defined tolerance limits. However, applying a similar formula to software is problematic since it assumes that the users have a perfect knowledge of how and when to apply the software and that if the software operates correctly under one set of conditions it will operate correctly under all conditions Methods: In the approach presented here the personnel involved with the software are included as an integral part of the system. Activities performed to improve the safety of the software are done with both software and people in mind. A learning oriented approach is taken, following the premise that the best approach to safety is increasing the understanding of those associated with the use or development of the software. Results: The software guidance document is organized by areas of knowledge related to use and development of software. The categories include: knowledge of the underlying algorithm and its limitations; knowledge of the operation of the software, such as input values, parameters, error messages, and interpretation of output; and knowledge of the environment for the software including both data and users. Conclusion: We propose a new approach to developing guidelines which is based on acquiring knowledge-rather than performing tests. The ultimate goal is to provide robust software guidelines which will be practical and effective

  20. SU-E-P-43: A Knowledge Based Approach to Guidelines for Software Safety

    Energy Technology Data Exchange (ETDEWEB)

    Salomons, G [Cancer Center of Southeastern Ontario & Queen’s University, Kingston, ON (Canada); Kelly, D [Royal Military College of Canada, Kingston, ON, CA (Canada)

    2015-06-15

    Purpose: In the fall of 2012, a survey was distributed to medical physicists across Canada. The survey asked the respondents to comment on various aspects of software development and use in their clinic. The survey revealed that most centers employ locally produced (in-house) software of some kind. The respondents also indicated an interest in having software guidelines, but cautioned that the realities of cancer clinics include variations, that preclude a simple solution. Traditional guidelines typically involve periodically repeating a set of prescribed tests with defined tolerance limits. However, applying a similar formula to software is problematic since it assumes that the users have a perfect knowledge of how and when to apply the software and that if the software operates correctly under one set of conditions it will operate correctly under all conditions Methods: In the approach presented here the personnel involved with the software are included as an integral part of the system. Activities performed to improve the safety of the software are done with both software and people in mind. A learning oriented approach is taken, following the premise that the best approach to safety is increasing the understanding of those associated with the use or development of the software. Results: The software guidance document is organized by areas of knowledge related to use and development of software. The categories include: knowledge of the underlying algorithm and its limitations; knowledge of the operation of the software, such as input values, parameters, error messages, and interpretation of output; and knowledge of the environment for the software including both data and users. Conclusion: We propose a new approach to developing guidelines which is based on acquiring knowledge-rather than performing tests. The ultimate goal is to provide robust software guidelines which will be practical and effective.

  1. Real-time multi-task operators support system

    International Nuclear Information System (INIS)

    Wang He; Peng Minjun; Wang Hao; Cheng Shouyu

    2005-01-01

    The development in computer software and hardware technology and information processing as well as the accumulation in the design and feedback from Nuclear Power Plant (NPP) operation created a good opportunity to develop an integrated Operator Support System. The Real-time Multi-task Operator Support System (RMOSS) has been built to support the operator's decision making process during normal and abnormal operations. RMOSS consists of five system subtasks such as Data Collection and Validation Task (DCVT), Operation Monitoring Task (OMT), Fault Diagnostic Task (FDT), Operation Guideline Task (OGT) and Human Machine Interface Task (HMIT). RMOSS uses rule-based expert system and Artificial Neural Network (ANN). The rule-based expert system is used to identify the predefined events in static conditions and track the operation guideline through data processing. In dynamic status, Back-Propagation Neural Network is adopted for fault diagnosis, which is trained with the Genetic Algorithm. Embedded real-time operation system VxWorks and its integrated environment Tornado II are used as the RMOSS software cross-development. VxGUI is used to design HMI. All of the task programs are designed in C language. The task tests and function evaluation of RMOSS have been done in one real-time full scope simulator. Evaluation results show that each task of RMOSS is capable of accomplishing its functions. (authors)

  2. Manpower development for safe operation of nuclear power plant. China. Emergency operating procedures. Activity: 5.1.4-Task-11. Technical report

    International Nuclear Information System (INIS)

    Walsh, L.A.

    1994-01-01

    This report covers the period of engagement from July 11, 1994 through July 22, 1994. The events and topics of discussion are as follows: History of Emergency Operating Procedure EOP Development; Emergency Operating Procedures (Event Based, Critical Safe Function Status Trees and Functional Recovery Response Procedures); Transition from Emergency Operating Procedures to Severe Accident Management Guidelines

  3. RTNS-II operations guidebook

    International Nuclear Information System (INIS)

    Heikkinen, D.W.

    1985-01-01

    This guidebook is intended to provide training criteria, procedures and guidelines for operation of the RTNS-II neutron sources and ancilliary equipment. Use of this document requires full knowledge of the RTNS-II Facility Safety Procedure (FSP) and any Operational Safety Procedures (OSP) in effect. The RTNS-II FSP defines the hazards which may be encountered at RTNS-II and defines the procedures which must be followed in performing any task including operations. The purpose of this document is to provide a central source of detailed information concerning systems and equipment used in operating the RTNS-II neutron sources on a day-to-day basis. All members of the Operations Group are expected to be familiar with its contents. It is also intended to be used in training new members of the Operations Group

  4. WSES Jerusalem guidelines for diagnosis and treatment of acute appendicitis.

    Science.gov (United States)

    Di Saverio, Salomone; Birindelli, Arianna; Kelly, Micheal D; Catena, Fausto; Weber, Dieter G; Sartelli, Massimo; Sugrue, Michael; De Moya, Mark; Gomes, Carlos Augusto; Bhangu, Aneel; Agresta, Ferdinando; Moore, Ernest E; Soreide, Kjetil; Griffiths, Ewen; De Castro, Steve; Kashuk, Jeffry; Kluger, Yoram; Leppaniemi, Ari; Ansaloni, Luca; Andersson, Manne; Coccolini, Federico; Coimbra, Raul; Gurusamy, Kurinchi S; Campanile, Fabio Cesare; Biffl, Walter; Chiara, Osvaldo; Moore, Fred; Peitzman, Andrew B; Fraga, Gustavo P; Costa, David; Maier, Ronald V; Rizoli, Sandro; Balogh, Zsolt J; Bendinelli, Cino; Cirocchi, Roberto; Tonini, Valeria; Piccinini, Alice; Tugnoli, Gregorio; Jovine, Elio; Persiani, Roberto; Biondi, Antonio; Scalea, Thomas; Stahel, Philip; Ivatury, Rao; Velmahos, George; Andersson, Roland

    2016-01-01

    Acute appendicitis (AA) is among the most common cause of acute abdominal pain. Diagnosis of AA is challenging; a variable combination of clinical signs and symptoms has been used together with laboratory findings in several scoring systems proposed for suggesting the probability of AA and the possible subsequent management pathway. The role of imaging in the diagnosis of AA is still debated, with variable use of US, CT and MRI in different settings worldwide. Up to date, comprehensive clinical guidelines for diagnosis and management of AA have never been issued. In July 2015, during the 3rd World Congress of the WSES, held in Jerusalem (Israel), a panel of experts including an Organizational Committee and Scientific Committee and Scientific Secretariat, participated to a Consensus Conference where eight panelists presented a number of statements developed for each of the eight main questions about diagnosis and management of AA. The statements were then voted, eventually modified and finally approved by the participants to The Consensus Conference and lately by the board of co-authors. The current paper is reporting the definitive Guidelines Statements on each of the following topics: 1) Diagnostic efficiency of clinical scoring systems, 2) Role of Imaging, 3) Non-operative treatment for uncomplicated appendicitis, 4) Timing of appendectomy and in-hospital delay, 5) Surgical treatment 6) Scoring systems for intra-operative grading of appendicitis and their clinical usefulness 7) Non-surgical treatment for complicated appendicitis: abscess or phlegmon 8) Pre-operative and post-operative antibiotics.

  5. The Operator's Diagnosis Task under Abnormal Operating Conditions in Industrial Process Plant

    DEFF Research Database (Denmark)

    Goodstein, L.P.; Pedersen, O.M.; Rasmussen, Jens

    1974-01-01

    Analysis of serious accidents in connection with the operation of technical installations demonstrate that the diagnosis task which confronts personnel under non-normal plant conditions is a critical one. This report presents a preliminary outline of characteristic traits connected with the task...... of diagnosis for use in discussions of (a) the studies which are necessary in order to formulate the operator's diagnostic procedures and (b) the possibilities which exists for supporting these procedures through appropriate data processing and display in the control system. At the same time, attempts are made...

  6. 76 FR 60017 - Technical Conference on Penalty Guidelines; Notice of Technical Conference on Penalty Guidelines

    Science.gov (United States)

    2011-09-28

    ... Conference on Penalty Guidelines; Notice of Technical Conference on Penalty Guidelines The staff of the... the Penalty Guidelines, which the Commission issued on September 17, 2010.\\1\\ The conference will be... impact of the Penalty Guidelines on compliance and enforcement matters. More information on the topics to...

  7. Physical Activity Guidelines

    Science.gov (United States)

    ... use this site. health.gov Physical Activity Guidelines Physical Activity Physical activity is key to improving the health of the Nation. Based on the latest science, the Physical Activity Guidelines for Americans is an essential resource for ...

  8. Preliminary safety evaluation of an aircraft impact on a near-surface radioactive waste repository

    Energy Technology Data Exchange (ETDEWEB)

    Lo Frano, R.; Forasassi, G.; Pugliese, G. [Department of Industrial and Civil Engineering (DICI), University of Pisa, Pisa (Italy)

    2013-07-01

    The aircraft impact accident has become very significant in the design of a nuclear facilities, particularly, after the tragic September 2001 event, that raised the public concern about the potential damaging effects that the impact of a large civilian airplane could bring in safety relevant structures. The aim of this study is therefore to preliminarily evaluate the global response and the structural effects induced by the impact of a military or commercial airplane (actually considered as a 'beyond design basis' event) into a near surface radioactive waste (RWs) disposal facility. The safety evaluation was carried out according to the International safety and design guidelines and in agreement with the stress tests requirements for the security track. To achieve the purpose, a lay out and a scheme of a possible near surface repository, like for example those of the El Cabril one, were taken into account. In order to preliminarily perform a reliable analysis of such a large-scale structure and to determine the structural effects induced by such a types of impulsive loads, a realistic, but still operable, numerical model with suitable materials characteristics was implemented by means of FEM codes. In the carried out structural analyses, the RWs repository was considered a 'robust' target, due to its thicker walls and main constitutive materials (steel and reinforced concrete). In addition to adequately represent the dynamic response of repository under crashing, relevant physical phenomena (i.e. penetration, spalling, etc.) were simulated and analysed. The preliminary assessment of the effects induced by the dynamic/impulsive loads allowed generally to verify the residual strength capability of the repository considered. The obtained preliminary results highlighted a remarkable potential to withstand the impact of military/large commercial aircraft, even in presence of ongoing concrete progressive failure (some penetration and spalling of the

  9. Guidelines for selecting codes for ground-water transport modeling of low-level waste burial sites. Volume 2. Special test cases

    International Nuclear Information System (INIS)

    Simmons, C.S.; Cole, C.R.

    1985-08-01

    This document was written for the National Low-Level Waste Management Program to provide guidance for managers and site operators who need to select ground-water transport codes for assessing shallow-land burial site performance. The guidance given in this report also serves the needs of applications-oriented users who work under the direction of a manager or site operator. The guidelines are published in two volumes designed to support the needs of users having different technical backgrounds. An executive summary, published separately, gives managers and site operators an overview of the main guideline report. Volume 1, titled ''Guideline Approach,'' consists of Chapters 1 through 5 and a glossary. Chapters 2 through 5 provide the more detailed discussions about the code selection approach. This volume, Volume 2, consists of four appendices reporting on the technical evaluation test cases designed to help verify the accuracy of ground-water transport codes. 20 refs

  10. An exploration of how guideline developer capacity and guideline implementability influence implementation and adoption: study protocol

    Directory of Open Access Journals (Sweden)

    Lemieux-Charles Louise

    2009-07-01

    Full Text Available Abstract Background Practice guidelines can improve health care delivery and outcomes but several issues challenge guideline adoption, including their intrinsic attributes, and whether and how they are implemented. It appears that guideline format may influence accessibility and ease of use, which may overcome attitudinal barriers of guideline adoption, and appear to be important to all stakeholders. Guideline content may facilitate various forms of decision making about guideline adoption relevant to different stakeholders. Knowledge and attitudes about, and incentives and capacity for implementation on the part of guideline sponsors may influence whether and how they develop guidelines containing these features, and undertake implementation. Examination of these issues may yield opportunities to improve guideline adoption. Methods The attributes hypothesized to facilitate adoption will be expanded by thematic analysis, and quantitative and qualitative summary of the content of international guidelines for two primary care (diabetes, hypertension and institutional care (chronic ulcer, chronic heart failure topics. Factors that influence whether and how guidelines are implemented will be explored by qualitative analysis of interviews with individuals affiliated with guideline sponsoring agencies. Discussion Previous research examined guideline implementation by measuring rates of compliance with recommendations or associated outcomes, but this produced little insight on how the products themselves, or their implementation, could be improved. This research will establish a theoretical basis upon which to conduct experimental studies to compare the cost-effectiveness of interventions that enhance guideline development and implementation capacity. Such studies could first examine short-term outcomes predictive of guideline utilization, such as recall, attitude toward, confidence in, and adoption intention. If successful, then long-term objective

  11. Testing post-editing guidelines

    DEFF Research Database (Denmark)

    Flanagan, Marian; Christensen, Tina Paulsen

    2014-01-01

    guidelines to use in translator training programmes. Recently, the first set of publicly available industry-focused PE guidelines (for ‘good enough’ and ‘publishable’ quality) were developed by Translation Automation User Society (TAUS) in partnership with the Centre for Global Intelligent Content (CNGL......), which can be used as a basis on which to instruct post-editors in professional environments. This paper reports on a qualitative study that investigates how trainee translators on an MA course, which is aimed at preparing the trainees for the translation industry, interpret these PE guidelines...... for publishable quality. The findings suggest trainees have difficulties interpreting the guidelines, primarily due to trainee competency gaps, but also due to the wording of the guidelines. Based on our findings we propose training measures to address these competency gaps. Furthermore, we provide post...

  12. Environmental Survey preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    1988-04-01

    This report presents the preliminary findings from the first phase of the Environmental Survey of the United States Department of Energy (DOE) Sandia National Laboratories conducted August 17 through September 4, 1987. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with Sandia National Laboratories-Albuquerque (SNLA). The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. This phase of the Survey involves the review of existing site environmental data, observations of the operations carried on at SNLA, and interviews with site personnel. 85 refs., 49 figs., 48 tabs.

  13. Appraising and comparing pressure ulcer guidelines.

    Science.gov (United States)

    Wimpenny, Peter; van Zelm, Ruben

    2007-01-01

    Whilst considerable activity has been related to guideline development for nurses regarding pressure ulcer prevention and management, no attempt has been made to comparatively evaluate these guidelines against some form of quality indicators. To compare and contrast four national pressure ulcer guidelines, and identify similarities and differences in their quality and content. An international comparative appraisal method, using the AGREE (Appraisal of Guidelines Research and Evaluation) instrument, was undertaken to appraise four published pressure ulcer guidelines. Two further domains were added to the AGREE instrument to assess comparability of the guidelines and their perceived contribution to practice. An international group undertook the comparative appraisal. The domain scores for each guideline show some but not total agreement among reviewers. One particular set of guidelines was identified as scoring highest in a majority of AGREE domains. Overall, evidence of variability exists between pressure ulcer guidelines and common areas of development to consider for all guidelines. The results raise many questions concerning the "best" pressure ulcer guideline to use, particularly related to the AGREE scoring. Some notable shortcomings exist in all the pressure ulcer guidelines reviewed and these shortcomings need to be addressed from a quality perspective. However, other issues such as style of reporting and potential contribution to practice might more fully affect choice by practitioners as opposed to guideline developers. Notable differences exist among the four guidelines that are possibly explained by different approaches to development and also because of different cultural factors and intentions for use. Whilst the AGREE tool identifies the quality of the guideline development process it still requires local engagement with practitioners to determine which guideline should be implemented.

  14. Large Hadron Collider commissioning and first operation.

    Science.gov (United States)

    Myers, S

    2012-02-28

    A history of the commissioning and the very successful early operation of the Large Hadron Collider (LHC) is described. The accident that interrupted the first commissioning, its repair and the enhanced protection system put in place are fully described. The LHC beam commissioning and operational performance are reviewed for the period from 2010 to mid-2011. Preliminary plans for operation and future upgrades for the LHC are given for the short and medium term.

  15. Japanese Guideline for Atopic Dermatitis

    Directory of Open Access Journals (Sweden)

    Ichiro Katayama

    2011-01-01

    The basics of treatment discussed in this guideline are based on the “Guidelines for the Treatment of Atopic Dermatitis 2008” prepared by the Health and Labour Sciences Research and the “Guidelines for the Management of Atopic Dermatitis 2009 (ADGL2009” prepared by the Atopic Dermatitis Guidelines Advisory Committee, Japanese Society of Allergology in principle.

  16. Trial application of guidelines for nuclear plant response to an earthquake

    International Nuclear Information System (INIS)

    Schmidt, W.; Oliver, R.; O'Connor, W.

    1993-09-01

    Guidelines have been developed to assist nuclear plant personnel in the preparation of earthquake response procedures for nuclear power plants. These guidelines are published in EPRI report NP-6695, ''Guidelines for Nuclear Plant Response to an Earthquake,'' dated December 1989. This report includes two sets of nuclear plant procedures which were prepared to implement the guidelines of EPRI report NP-6695. The first set were developed by the Toledo Edison Company Davis-Besse plant. Davis-Besse is a pressurized water reactor (PWR) and contains relatively standard seismic monitoring instrumentation typical of many domestic nuclear plants. The second set of procedures were prepared by Yankee Atomic Electric Company for the Vermont Yankee facility. This plant is a boiling water reactor (BWR) with state-of-the-art seismic monitoring and PC-based data processing equipment, software developed specifically to implement the OBE Exceedance Criterion presented in EPRI report NP-5930, ''A Criterion for Determining Exceedance of the operating Basis Earthquake.'' The two sets of procedures are intended to demonstrate how two different nuclear utilities have interpreted and applied the EPRI guidance given in report NP-6695

  17. The Evolution of Peace Operations Doctrine

    National Research Council Canada - National Science Library

    Lovelock, Richard

    2002-01-01

    .... Capable warfighting forces must operate among the people, using the guidelines provided by maneuverist doctrine and adapted to local conditions to enable the military, in cooperation with the police, to find (locate), fix (control or shape...

  18. Integrating guideline development and implementation: analysis of guideline development manual instructions for generating implementation advice

    Directory of Open Access Journals (Sweden)

    Gagliardi Anna R

    2012-07-01

    Full Text Available Abstract Background Guidelines are important tools that inform healthcare delivery based on best available research evidence. Guideline use is in part based on quality of the guidelines, which includes advice for implementation and has been shown to vary. Others hypothesized this is due to limited instructions in guideline development manuals. The purpose of this study was to examine manual instructions for implementation advice. Methods We used a directed and summative content analysis approach based on an established framework of guideline implementability. Six manuals identified by another research group were examined to enumerate implementability domains and elements. Results Manuals were similar in content but lacked sufficient detail in particular domains. Most frequently this was Accomodation, which includes information that would help guideline users anticipate and/or overcome organizational and system level barriers. In more than one manual, information was also lacking for Communicability, information that would educate patients or facilitate their involvement in shared decision making, and Applicability, or clinical parameters to help clinicians tailor recommendations for individual patients. Discussion Most manuals that direct guideline development lack complete information about incorporating implementation advice. These findings can be used by those who developed the manuals to consider expanding their content in these domains. It can also be used by guideline developers as they plan the content and implementation of their guidelines so that the two are integrated. New approaches for guideline development and implementation may need to be developed. Use of guidelines might be improved if they included implementation advice, but this must be evaluated through ongoing research.

  19. [The German Program for Disease Management Guidelines: COPD Guideline 2006. Short review].

    Science.gov (United States)

    Ollenschläger, Günter; Kopp, Ina; Lelgemann, Monika

    2007-01-15

    In Germany, the first national consensus on evidence-based recommendations for COPD prevention and disease management was reached in spring 2006. After a development period of 9 months, the National Disease Management Guideline COPD was finalized by nominal group process under the authorship of the scientific societies for pneumology (DGP and Atemwegsliga), general internal medicine (DGIM), family medicine (DEGAM), and the Drug Commission of the German Medical Association (AKDAE). The recommendations' main sources are the NICE COPD Guideline 2004, the GOLD Recommendations as well as existing German guidelines and reviews of recent scientific evidence. The article gives an overview on authors, sources, and key recommendations of the German National Disease Management Guideline COPD 2006 (www.copd.versorgungsleitlinien.de).

  20. Effective corrective actions to enhance operational safety of nuclear installations

    International Nuclear Information System (INIS)

    2005-07-01

    The safe operation of nuclear power plants around the world and the prevention of incidents in these installations remain key concerns for the nuclear community. In this connection the feedback of operating experience plays a major role: every nuclear plant operator needs to have a system in place to identify and feed back the lessons learned from operating experience and to implement effective corrective actions to prevent safety events from reoccurring. An effective operating experience programme also includes a proactive approach that is aimed at preventing the first-time occurrence of safety events. In April 2003, the IAEA issued the PROSPER guidelines for nuclear installations to strengthen and enhance their own operating experience process and for self-assessment on the effectiveness of the feedback process. Subsequently, in the course of the Operational Safety Review Teams missions conducted by the IAEA that focused on the operational safety practices of nuclear power plants, the IAEA enhanced the review of the operating experience in nuclear power plants by implementing a new module that is derived from these guidelines. In order to highlight the effective implementation of the operating experience programme and to provide practical assistance in this area, the IAEA organized workshops and conferences to discuss recent trends in operating experience. The IAEA also performed assistance and review missions at plants and corporate organizations. The IAEA is further developing advice and assistance on operating experience feedback programmes and is reporting on good practices. The present publication is the outcome of two years of coordinated effort involving the participation of experts of nuclear organizations in several Member States. It provides information and good practices for successfully establishing an effective corrective actions programme. This publication forms part of a series that develops the principles set forth in these guidelines

  1. Maintenance Trades Guidelines

    Science.gov (United States)

    Weidner, Theodore J.

    2008-01-01

    In 2002, APPA published "Maintenance Staffing Guidelines for Educational Facilities," the first building maintenance trades staffing guideline designed to assist educational facilities professionals with their staffing needs. addresses how facilities professionals can determine the appropriate size and mix of their organization. Contents…

  2. Implementation of an evidence-based guideline on fluid resuscitation: lessons learnt for future guidelines

    NARCIS (Netherlands)

    Tabbers, M.M.; Boluyt, N.; Offringa, M.

    2010-01-01

    There is little experience with the nationwide implementation of an evidence-based pediatric guideline on first-choice fluid for resuscitation in hypovolemia. We investigated fluid prescribing behavior at (1) guideline development, (2) after guideline development, and (3) after active implementation

  3. Emergency Response Guideline Development

    International Nuclear Information System (INIS)

    Gary D Storrick

    2007-01-01

    Task 5 of the collaborative effort between ORNL, Brazil, and Westinghouse for the International Nuclear Energy Research Initiative entitled 'Development of Advanced Instrumentation and Control for an Integrated Primary System Reactor' focuses on operator control and protection system interaction, with particular emphasis on developing emergency response guidelines (ERGs). As in the earlier tasks, we will use the IRIS plant as a specific example of an integrated primary system reactor (IPSR) design. The present state of the IRIS plant design--specifically, the lack of a detailed secondary system design--precludes establishing detailed emergency procedures at this time. However, we can create a structure for their eventual development. This report summarizes our progress to date. Section 1.2 describes the scope of this effort. Section 2 compares IPSR ERG development to the recent AP1000 effort, and identifies three key plant differences that affect the ERGs and control room designs. The next three sections investigate these differences in more detail. Section 3 reviews the IRIS Safety-by-Design philosophy and its impact on the ERGs. Section 4 looks at differences between the IRIS and traditional loop PWR I and C Systems, and considers their implications for both control room design and ERG development. Section 5 examines the implications of having one operating staff control multiple reactor units. Section 6 provides sample IRIS emergency operating procedures (EOPs). Section 7 summarizes our conclusions

  4. Guidelines for the review of advanced controls and displays

    International Nuclear Information System (INIS)

    Wachtel, J.; O'Hara, J.M.

    1991-01-01

    Advanced control room (ACR) concepts are being developed and refined in the commercial nuclear industry as part of future reactor designs. These ACRs will utilize advanced human-system interface (HSI) technologies which may have significant implications for plant safety in that they may affect: (1) the operators' overall role (function) in the system; (2) the methods by which operators receive information about system status; (3) the ways in which the operators interact with the system; and (4) the requirements on operators to understand and supervise an increasingly complex system. The Nuclear Regulatory Commission (NRC) reviews control room designs to ensure that they incorporate good human factors engineering principles so as to support operator performance and reliability necessary to protect public health and safety. The principal guidance available to the NRC (NUREG-0700) was developed more than ten years ago and does not address new technologies. Accordingly, the guidance must be updated. This paper discusses the development of an NRC Advanced Control Room Design Review Guideline

  5. Preliminary Safety Analysis Report for the Tokamak Physics Experiment

    International Nuclear Information System (INIS)

    Motloch, C.G.; Bonney, R.F.; Levine, J.D.; Masson, L.S.; Commander, J.C.

    1995-04-01

    This Preliminary Safety Analysis Report (PSAR), includes an indication of the magnitude of facility hazards, complexity of facility operations, and the stage of the facility life-cycle. It presents the results of safety analyses, safety assurance programs, identified vulnerabilities, compensatory measures, and, in general, the rationale describing why the Tokamak Physics Experiment (TPX) can be safely operated. It discusses application of the graded approach to the TPX safety analysis, including the basis for using Department of Energy (DOE) Order 5480.23 and DOE-STD-3009-94 in the development of the PSAR

  6. Diagnosis and Treatment of Polycystic Ovary Syndrome: An Endocrine Society Clinical Practice Guideline

    Science.gov (United States)

    Legro, Richard S.; Arslanian, Silva A.; Ehrmann, David A.; Hoeger, Kathleen M.; Murad, M. Hassan; Pasquali, Renato; Welt, Corrine K.

    2013-01-01

    Objective: The aim was to formulate practice guidelines for the diagnosis and treatment of polycystic ovary syndrome (PCOS). Participants: An Endocrine Society-appointed Task Force of experts, a methodologist, and a medical writer developed the guideline. Evidence: This evidence-based guideline was developed using the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) system to describe both the strength of recommendations and the quality of evidence. Consensus Process: One group meeting, several conference calls, and e-mail communications enabled consensus. Committees and members of The Endocrine Society and the European Society of Endocrinology reviewed and commented on preliminary drafts of these guidelines. Two systematic reviews were conducted to summarize supporting evidence. Conclusions: We suggest using the Rotterdam criteria for diagnosing PCOS (presence of two of the following criteria: androgen excess, ovulatory dysfunction, or polycystic ovaries). Establishing a diagnosis of PCOS is problematic in adolescents and menopausal women. Hyperandrogenism is central to the presentation in adolescents, whereas there is no consistent phenotype in postmenopausal women. Evaluation of women with PCOS should exclude alternate androgen-excess disorders and risk factors for endometrial cancer, mood disorders, obstructive sleep apnea, diabetes, and cardiovascular disease. Hormonal contraceptives are the first-line management for menstrual abnormalities and hirsutism/acne in PCOS. Clomiphene is currently the first-line therapy for infertility; metformin is beneficial for metabolic/glycemic abnormalities and for improving menstrual irregularities, but it has limited or no benefit in treating hirsutism, acne, or infertility. Hormonal contraceptives and metformin are the treatment options in adolescents with PCOS. The role of weight loss in improving PCOS status per se is uncertain, but lifestyle intervention is beneficial in overweight

  7. A review of clinical guidelines.

    LENUS (Irish Health Repository)

    Andrews, E J

    2012-02-03

    BACKGROUND: Clinical guidelines are increasingly used in patient management but few clinicians are familiar with their origin or appropriate application. METHODS: A Medline search using the terms \\'clinical guidelines\\' and \\'practice guidelines\\' was conducted. Additional references were sourced by manual searching from the bibliographies of articles located. RESULTS AND CONCLUSION: Clinical guidelines originated in the USA in the early 1980s, initially as a cost containment exercise. Significant improvements in the process and outcomes of care have been demonstrated following their introduction, although the extent of improvement varies considerably. The principles for the development of guidelines are well established but many published guidelines fall short of these basic quality criteria. Guidelines are only one aspect of improving quality and should be used within a wider framework of promoting clinical effectiveness. Understanding their limitations as well as their potential benefits should enable clinicians to have a clearer view of their place in everyday practice.

  8. Guidelines and workbook for assessment of organization and administration of utilities seeking operating license for a nuclear power plant. Guidelines for utility organization and administration plan. Volume 1, Revision 1

    International Nuclear Information System (INIS)

    Thurber, J.A.; Olson, J.; Osborn, R.N.; Sommers, P.; Widrig, R.D.

    1986-09-01

    Volumes 1 and 2 of this report are a partial response to the requirements of Item I.B.1.1 of the ''NRC Action Plan Developed as a Result of the TMI-2 Accident,'' NUREG-0660, and are designed to serve as a basis for replacing the earlier NUREG-0731, ''Guidelines for Utility Management Structure and Technical Resources.'' These Guidelines are intended to provide guidance to the user in preparing a written plan for a proposed nuclear organization and administration. The purpose of the Workbook (Vol. 2) is to guide the NRC reviewer through a systematic review and assessment of a proposed organization and administration. It is the NRC's intention to incorporate these Guidelines and Workbook into a future revision of the Standard Review Plan (SRP), NUREG-0800. However, at this time the report is being published so that the material may be used on a voluntary basis by industry to systematically prepare or evaluate their organization or administration plans. Use of the report by the NRC would not occur until after it has been incorpoarted in the SRP

  9. 40 CFR 417.153 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... operation of spray drying towers as defined above, the following values pertain: Effluent characteristic...) 1 Within the range 6.0 to 9.0. (b) For air quality restricted operation of a spray drying tower, but... Manufacture of Spray Dried Detergents Subcategory § 417.153 Effluent limitations guidelines representing the...

  10. Aircraft operations management manual

    Science.gov (United States)

    1992-01-01

    The NASA aircraft operations program is a multifaceted, highly diverse entity that directly supports the agency mission in aeronautical research and development, space science and applications, space flight, astronaut readiness training, and related activities through research and development, program support, and mission management aircraft operations flights. Users of the program are interagency, inter-government, international, and the business community. This manual provides guidelines to establish policy for the management of NASA aircraft resources, aircraft operations, and related matters. This policy is an integral part of and must be followed when establishing field installation policy and procedures covering the management of NASA aircraft operations. Each operating location will develop appropriate local procedures that conform with the requirements of this handbook. This manual should be used in conjunction with other governing instructions, handbooks, and manuals.

  11. Assessment of field training for nuclear operations personnel

    International Nuclear Information System (INIS)

    White, M.

    1995-08-01

    Training of station personnel is an important component of the safe operation of the nuclear generating station. On-the-job training (OJT) is an important component of training. The AECB initiated this project to develop a process to assess the effectiveness of OJT for field operators, and perform an initial trial of the developed process. This report describes the recommended process to assess the effectiveness of OJT for field operators, as well as the results of the initial assessment at Pickering Nuclear Generating Station. The assessment's conclusions included: (1) Ontario Hydro policies and procedures are generally consistent with industry guidelines requiring a systematic approach to training; (2) Pickering NGS field operator performance is not always consistent with documented station requirements and standards, nor industry guidelines and practices; and (3) The Pickering NGS field operator on-the-job training is not consistent with a systematic approach to training, a requirement recognized in Ontario Hydro's Policy NGD 113, and does not contribute to a high level of performance in field operator tasks. Recommendations are made regarding the use of the developed process for future assessments of on-the-job training at nuclear power plants. (author). 36 refs., 4 tabs., 3 figs

  12. From Clinical Practice Guidelines to Computer-interpretable Guidelines. A Literature Overview

    NARCIS (Netherlands)

    Latoszek-Berendsen, A.; Tange, H.; van den Herik, H. J.; Hasman, A.

    2010-01-01

    Background: Guidelines are among us for over 30 years. Initially they were used as algorithmic protocols by nurses and other ancillary personnel. Many physicians regarded the use of guidelines as cookbook medicine. However, quality and patient safety issues have changed the attitude towards

  13. Guidelines for radiological interventions

    International Nuclear Information System (INIS)

    Kauffmann, G.W.

    1998-01-01

    The German Radiological Society, in cooperation with other German professional bodies, set up draft Guidelines for Radiological Interventions and submitted them to the professional community for discussion. The Guidelines are meant to assess the potential of radiological interventions as treatment alternatives to surgery or aggressive therapy such as chemotherapy. In fact, technical practicability on its own is insufficient to warrant intervention. The Guidelines are systematically compiled notions and recommendations whose aim it is to provide support to physicians and patients in choosing suitable medical care provisions (prevention, diagnosis, therapy, aftertreatment) in specific circumstances. A complete Czech translation of the Guidelines is given. (P.A.)

  14. Guidelines for generators of hazardous chemical waste at LBL and guidelines for generators of radioactive and mixed waste at LBL

    International Nuclear Information System (INIS)

    1993-10-01

    The purpose of this document is to provide the acceptance criteria for the transfer of hazardous chemical waste to LBL's Hazardous Waste Handling Facility (HWHF). Hazardous chemical waste is a necessary byproduct of LBL's research and technical support activities. This waste must be handled properly if LBL is to operate safely and provide adequate protection to staff and the environment. These guidelines describe how you, as a generator of hazardous chemical waste, can meet LBL's acceptance criteria for hazardous chemical waste

  15. Measure Guideline: Heat Pump Water Heaters in New and Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, C.; Puttagunta, S.; Owens, D.

    2012-02-01

    This Building America Measure Guideline is intended for builders, contractors, homeowners, and policy-makers. This document is intended to explore the issues surrounding heat pump water heaters (HPWHs) to ensure that homeowners and contractors have the tools needed to appropriately and efficiently install HPWHs. Heat pump water heaters (HPWHs) promise to significantly reduce energy consumption for domestic hot water (DHW) over standard electric resistance water heaters (ERWHs). While ERWHs perform with energy factors (EFs) around 0.9, new HPWHs boast EFs upwards of 2.0. High energy factors in HPWHs are achieved by combining a vapor compression system, which extracts heat from the surrounding air at high efficiencies, with electric resistance element(s), which are better suited to meet large hot water demands. Swapping ERWHs with HPWHs could result in roughly 50% reduction in water heating energy consumption for 35.6% of all U.S. households. This Building America Measure Guideline is intended for builders, contractors, homeowners, and policy-makers. While HPWHs promise to significantly reduce energy use for DHW, proper installation, selection, and maintenance of HPWHs is required to ensure high operating efficiency and reliability. This document is intended to explore the issues surrounding HPWHs to ensure that homeowners and contractors have the tools needed to appropriately and efficiently install HPWHs. Section 1 of this guideline provides a brief description of HPWHs and their operation. Section 2 highlights the cost and energy savings of HPWHs as well as the variables that affect HPWH performance, reliability, and efficiency. Section 3 gives guidelines for proper installation and maintenance of HPWHs, selection criteria for locating HPWHs, and highlights of important differences between ERWH and HPWH installations. Throughout this document, CARB has included results from the evaluation of 14 heat pump water heaters (including three recently released HPWH

  16. Preliminary Hybrid Modeling of the Panama Canal: Operations and Salinity Diffusion

    Directory of Open Access Journals (Sweden)

    Luis Rabelo

    2012-01-01

    Full Text Available This paper deals with the initial modeling of water salinity and its diffusion into the lakes during lock operation on the Panama Canal. A hybrid operational model was implemented using the AnyLogic software simulation environment. This was accomplished by generating an operational discrete-event simulation model and a continuous simulation model based on differential equations, which modeled the salinity diffusion in the lakes. This paper presents that unique application and includes the effective integration of lock operations and its impact on the environment.

  17. Pre-operative skin preparation practices: results of the 2007 French national assessment.

    Science.gov (United States)

    Borgey, F; Thibon, P; Ertzscheid, M-A; Bernet, C; Gautier, C; Mourens, C; Bettinger, A; Aggoune, M; Galy, E; Lejeune, B; Kadi, Z

    2012-05-01

    Pre-operative skin preparation, aimed at reducing the endogenous microbial flora, is one of the main preventive measures employed to decrease the likelihood of surgical site infection. National recommendations on pre-operative management of infection risks were issued in France in 2004. To assess compliance with the French national guidelines for pre-operative skin preparation in 2007. A prospective audit was undertaken in French hospitals through interviews with patients and staff, and observation of professional practice. Compliance with five major criteria selected from the guidelines was studied: patient information, pre-operative showering, pre-operative hair removal, surgical site disinfection and documentation of these procedures. Data for 41,188 patients from all specialties at 609 facilities were analysed. Patients were issued with information about pre-operative showering in 88.2% of cases [95% confidence interval (CI) 87.9-88.5]. The recommended procedure for pre-operative showering, including hairwashing, with an antiseptic skin wash solution was followed by 70.3% of patients (95% CI 69.9-70.8); this percentage was higher when patients had received appropriate information (P pre-operative surgical hygiene, 82.3% of cases; and pre-operative site disinfection, 71.7% of cases. The essential content of the French guidelines seems to be understood, but reminders need to be issued. Some recommendations may need to be adapted for certain specialties. Copyright © 2012 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  18. Japanese Guideline for Atopic Dermatitis 2014

    Directory of Open Access Journals (Sweden)

    Ichiro Katayama

    2014-01-01

    The basics of treatment discussed in this guideline are based on the "Guidelines for the Treatment of Atopic Dermatitis 2008" prepared by the Health and Labour Sciences Research and the "Guidelines for the Management of Atopic Dermatitis 2012 (ADGL2012" prepared by the Atopic Dermatitis Guidelines Advisory Committee, Japanese Society of Allergology in principle. The guidelines for the treatment of atopic dermatitis are summarized in the "Japanese Guideline for the Diagnosis and Treatment of Allergic Disease 2013" together with those for other allergic diseases.

  19. Treatment of pneumothoraces at a tertiary centre: are we following the current guidelines?

    Science.gov (United States)

    Elsayed, Hany; Kent, Will; McShane, James; Page, Richard; Shackcloth, Michael

    2011-03-01

    The American College of Chest Physicians (ACCP) in 2001 and British Thoracic Society (BTS) in 1993 and 2003 published guidelines for the treatment of pneumothorax. Here, we review our experience of managing pneumothorax patients, comparing standards of management before and after the publication of the guidelines in 2003. One hundred and twenty patients were transferred to our care for management of pneumothorax between October 2001 and September 2006. One hundred and one patients underwent pleurectomy [28 by video-assisted thoracic surgery (VATS)]. There were 69 males and 32 females with a median age of 47 years (range 15-86 years). 24% (n=24) of patients had evidence of intrapleural infection at time of operation. This was more likely if the time to pleurectomy was >14 days (P=0.03). The median time of referral for patients in the pre-guideline group was 12 days [interquartile range (IQR) 9-12] while post guidelines it was 10 days (IQR 6-13). There was no statistical significance (P=0.09) between these groups in terms of time taken to refer patients. The ACCP and BTS guidelines are not being followed. Pneumothoraces should be managed by chest physicians who are aware of the current guidelines. Impact of delayed referral in the form of increased incidence of morbidity and financial burdens on hospitals needs to be recognized.

  20. Incorporating a gender perspective into the development of clinical guidelines: a training course for guideline developers

    Directory of Open Access Journals (Sweden)

    Burgers Jako S

    2007-11-01

    Full Text Available Abstract Background Dutch guideline-developing organizations do not focus systematically on differences between men and women when developing guidelines, even though there is increasing evidence that being male or female may have an effect on health and health outcomes. In collaboration with two prominent Dutch guideline-developing organizations, we designed a training course to encourage systematic attention to sex differences in guideline development procedures. Methods The course is targeted towards guideline developers. Its aims are to improve awareness concerning the relevance of considering sex differences in the guideline development process, as well as the competence and skills necessary for putting this into practice. The design and teaching methods of the course are based on adult learning styles and principles of changing provider behaviour. It was adjusted to the working methods of guideline organizations. The course was taught to, and evaluated by, a group of staff members from two guideline organizations in the Netherlands. Results The course consists of five modules, each of which corresponds to a key step in the guideline development process. The participants rated the training course positively on content, programme, and trainers. Their written comments suggest that the course met its objectives. Conclusion The training course is the first to address sex differences in guideline development. Results from the pilot test suggest that the course achieved its objectives. Because its modules and teaching methods of the course are widely transferable, the course could be useful for many organizations that are involved in developing guidelines. Follow-up studies are needed to assess the long-term effect of the course on the actions of guideline developers and its utility in other settings.

  1. Smart home design and operation preferences of Americans and Koreans.

    Science.gov (United States)

    Jeong, Kyeong-Ah; Salvendy, Gavriel; Proctor, Robert W

    2010-05-01

    The purpose of the present study was to generate both culture-specific and universal design and operational guidelines for smart homes. Questionnaire surveys were performed in the USA and South Korea to collect data on preferences for various aspects of the design and operation of smart homes. The factors that the survey participants considered most important were derived through factor analyses of the survey data and the responses of Americans and Koreans were compared to generate culture-specific guidelines. The five factors derived were: 1) environmental connection and control; 2) smart devices (appliances) and their control; 3) physical safety and security concerns; 4) comfort and relaxation issues; 5) control restriction issues. The two cultures showed different preference structures with statistical significance for all five factors. Prediction capability of the derived factors was also examined through multiple regressions for buying intention, interest, self-vision of living, moving intention, living satisfaction and perceived time and effort savings. 'Environmental connection and control' and 'smart devices (appliances) and their control' seemed to be the most influential factors for Americans and Koreans, respectively. STATEMENT OF RELEVANCE: Analysis of a survey of design and operational preferences for smart homes yielded five factors on which US and South Korean respondents differed. These factors form the basis for culture-specific guidelines, which, along with universal guidelines, should be followed in design of user-centred smart homes.

  2. Negative-pressure wound therapy with instillation: international consensus guidelines.

    Science.gov (United States)

    Kim, Paul J; Attinger, Christopher E; Steinberg, John S; Evans, Karen K; Lehner, Burkhard; Willy, Christian; Lavery, Larry; Wolvos, Tom; Orgill, Dennis; Ennis, William; Lantis, John; Gabriel, Allen; Schultz, Gregory

    2013-12-01

    Negative-pressure wound therapy with instillation is increasingly utilized as an adjunct therapy for a wide variety of wounds. Despite its growing popularity, there is a paucity of evidence and lack of guidance to provide effective use of this therapy. A panel of experts was convened to provide guidance regarding the appropriate use of negative-pressure wound therapy with instillation. A face-to-face meeting was held where the available evidence was discussed and individual clinical experience with this therapy was shared. Follow-up communication among the panelists continued until consensus was achieved. The final consensus recommendations were derived through more than 80 percent agreement among the panelists. Nine consensus statements were generated that address the appropriate use of negative-pressure wound therapy with instillation. The question of clinical effectiveness of this therapy was not directly addressed by the consensus panel. This document serves as preliminary guidelines until more robust evidence emerges that will support or modify these consensus recommendations.

  3. Guidelines for the Layout and Contents of Safety Reports for Stationary Nuclear Power Plants

    International Nuclear Information System (INIS)

    1970-01-01

    The purpose of the present document is to suggest guidelines for the organization and contents of the Safety Reports which support the request for authorization to construct and operate a nuclear power plant incorporating one or more reactors. Safety Reports represent the principal communication between the applicant and the Regulatory Body, as outlined in the Code of Practice for the Safe Operation of Nuclear Power Plants. It should be understood that these Safety Reports will be a valuable document for the applicant. They should contain, therefore, precise information on the plant and its operating conditions. The writing of Safety Reports should be considered an opportunity to enhance the safety of the plant and its operating conditions. Their main purpose is to provide information to permit the assessment of the nuclear safety implications which may arise from the establishment of the plant at the chosen site with due consideration to the health and safety of the general public and the operating personnel. Safety Reports should include information such as design bases, site and plant characteristics, limits and conditions, conduct of operation and safety analyses, in such way that the Regulatory Body may be able to evaluate the safety of the plant. The applicant should consider the present guidelines as a series of recommendations to be interpreted according to each specific case.

  4. [The German Program for Disease Management Guidelines: CHD Guideline 2006. Short review].

    Science.gov (United States)

    Ollenschläger, Günter; Lelgemann, Monika; Kopp, Ina

    2006-12-15

    In Germany, the first national consensus on evidence-based recommendations for disease management in patients with chronic coronary heart disease was reached in summer 2006. After a development period of 4 years, the National Disease Management Guideline Chronic Coronary Heart Disease was finalized by nominal group process under the authorship of the scientific associations for cardiac rehabilitation (DGPR), cardiac surgery (DGTHG), cardiology (DGK), general internal medicine (DGIM), family medicine (DEGAM), and the Drug Commission of the German Medical Association (AKDAE). The recommendations' main sources are the ACC/AHA guidelines 2002 updates as well as existing German guidelines and reviews of recent scientific evidence. The article gives an overview on authors, sources, and key recommendations of the German National Disease Management Guideline Chronic Coronary Heart Disease 2006 (www.khk.versorgungsleitlinie.de).

  5. Development of inspection and evaluation guidelines for light water reactor internals

    International Nuclear Information System (INIS)

    Aoki, T.; Yamashita, H.; Sakai, K.

    2002-01-01

    reasonable and clarify the technical reasons or rationale to obtain the public acceptance. This is essential not only to plant operation management but also to fulfilling the accountability for the standard rules. Based on the understanding described above, the Thermal and Nuclear Power Engineering Society (TENPES) has organized a committee named 'The Committee on Inspection and Evaluation Guidelines for Light Water Reactor Internals' to develop the guidelines necessary for the inspection, evaluation and repair of PWR and BWR reactor internals. The outline of the guidelines developed by the TENPES committee is presented herein. (author)

  6. Comparison of pre-operative dGEMRIC imaging with intra-operative findings in femoroacetabular impingement: preliminary findings

    International Nuclear Information System (INIS)

    Bittersohl, Bernd; Apprich, Sebastian; Siebenrock, Klaus A.; Mamisch, Tallal Charles; Hosalkar, Harish S.; Werlen, Stefan A.

    2011-01-01

    To study standard MRI and dGEMRIC in patients with symptomatic FAI undergoing surgical intervention and compare them with intra-operative findings to see if they were corroborative. Sixteen patients with symptomatic FAI that warranted surgical intervention were prospectively studied. All patients underwent plain radiographic series for FAI assessment followed by standard MRI and dGEMRIC. Subsequently, patients were surgically treated with safe dislocation and the joint was evaluated for any macroscopic signs of damaged cartilage. Data were statistically analyzed. A total of 224 zones in 16 patients were evaluated. One hundred and sixteen zones were intra-operatively rated as normal with mean T1 values of 510.1 ms ± 141.2 ms. Eighty zones had evidence of damage with mean T1 values of 453.1 ms ± 113.6 ms. The difference in these T1 values was significant (p = 0.003). Correlation between standard MRI and intra-operative findings was moderate (r = 0.535, p < 0.001). Intra-operative findings revealed more damage than standard MRI. On standard MRI, 68.6% zones were graded normal while 31.4% had evidence of damage. On intra-operative visualization, 56.4% zones were graded normal and 43.6% had evidence of damage. Correlation between dGEMRIC and intra-operative findings turned out to be weak (r = 0.114, p < 0.126). On T1 assessment 31.4% of zones were graded as normal and 68.6% as damaged. dGEMRIC was significantly different between normal and affected cartilage based on intra-operative assessment. The correlation for morphological findings was limited, underestimating defects. By combining morphological with biochemical assessment dGEMRIC may play some role in the future to prognosticate outcomes and facilitate surgical planning and intervention. (orig.)

  7. Japanese guidelines for atopic dermatitis 2017

    Directory of Open Access Journals (Sweden)

    Ichiro Katayama

    2017-04-01

    The basics of treatment discussed in this guideline are based on the “Guidelines for the Treatment of Atopic Dermatitis 2008” prepared by the Health and Labour Sciences Research and the “Guidelines for the Management of Atopic Dermatitis 2015 (ADGL2015” prepared by the Atopic Dermatitis Guidelines Advisory Committee, Japanese Society of Allergology in principle. The guidelines for the treatment of atopic dermatitis are summarized in the “Japanese Guideline for the Diagnosis and Treatment of Allergic Disease 2016” together with those for other allergic diseases.

  8. Preliminary Framework for Human-Automation Collaboration

    International Nuclear Information System (INIS)

    Oxstrand, Johanna Helene; Le Blanc, Katya Lee; Spielman, Zachary Alexander

    2015-01-01

    The Department of Energy's Advanced Reactor Technologies Program sponsors research, development and deployment activities through its Next Generation Nuclear Plant, Advanced Reactor Concepts, and Advanced Small Modular Reactor (aSMR) Programs to promote safety, technical, economical, and environmental advancements of innovative Generation IV nuclear energy technologies. The Human Automation Collaboration (HAC) Research Project is located under the aSMR Program, which identifies developing advanced instrumentation and controls and human-machine interfaces as one of four key research areas. It is expected that the new nuclear power plant designs will employ technology significantly more advanced than the analog systems in the existing reactor fleet as well as utilizing automation to a greater extent. Moving towards more advanced technology and more automation does not necessary imply more efficient and safer operation of the plant. Instead, a number of concerns about how these technologies will affect human performance and the overall safety of the plant need to be addressed. More specifically, it is important to investigate how the operator and the automation work as a team to ensure effective and safe plant operation, also known as the human-automation collaboration (HAC). The focus of the HAC research is to understand how various characteristics of automation (such as its reliability, processes, and modes) effect an operator's use and awareness of plant conditions. In other words, the research team investigates how to best design the collaboration between the operators and the automated systems in a manner that has the greatest positive impact on overall plant performance and reliability. This report addresses the Department of Energy milestone M4AT-15IN2302054, Complete Preliminary Framework for Human-Automation Collaboration, by discussing the two phased development of a preliminary HAC framework. The framework developed in the first phase was used as

  9. Updating Human Factors Engineering Guidelines for Conducting Safety Reviews of Nuclear Power Plants

    International Nuclear Information System (INIS)

    O'Hara, J.M.; Higgins, J.; Fleger, Stephen

    2011-01-01

    The U.S. Nuclear Regulatory Commission (NRC) reviews the human factors engineering (HFE) programs of applicants for nuclear power plant construction permits, operating licenses, standard design certifications, and combined operating licenses. The purpose of these safety reviews is to help ensure that personnel performance and reliability are appropriately supported. Detailed design review procedures and guidance for the evaluations is provided in three key documents: the Standard Review Plan (NUREG-0800), the HFE Program Review Model (NUREG-0711), and the Human-System Interface Design Review Guidelines (NUREG-0700). These documents were last revised in 2007, 2004 and 2002, respectively. The NRC is committed to the periodic update and improvement of the guidance to ensure that it remains a state-of-the-art design evaluation tool. To this end, the NRC is updating its guidance to stay current with recent research on human performance, advances in HFE methods and tools, and new technology being employed in plant and control room design. This paper describes the role of HFE guidelines in the safety review process and the content of the key HFE guidelines used. Then we will present the methodology used to develop HFE guidance and update these documents, and describe the current status of the update program.

  10. Revised version of quality guidelines for presurgical epilepsy evaluation and surgical epilepsy therapy issued by the Austrian, German, and Swiss working group on presurgical epilepsy diagnosis and operative epilepsy treatment.

    Science.gov (United States)

    Rosenow, Felix; Bast, Thomas; Czech, Thomas; Feucht, Martha; Hans, Volkmar H; Helmstaedter, Christoph; Huppertz, Hans-Jürgen; Noachtar, Soheyl; Oltmanns, Frank; Polster, Tilman; Seeck, Margitta; Trinka, Eugen; Wagner, Kathrin; Strzelczyk, Adam

    2016-08-01

    The definition of minimal standards remains pivotal as a basis for a high standard of care and as a basis for staff allocation or reimbursement. Only limited publications are available regarding the required staffing or methodologic expertise in epilepsy centers. The executive board of the working group (WG) on presurgical epilepsy diagnosis and operative epilepsy treatment published the first guidelines in 2000 for Austria, Germany, and Switzerland. In 2014, revised guidelines were published and the WG decided to publish an unaltered English translation in this report. Because epilepsy surgery is an elective procedure, quality standards are particularly high. As detailed in the first edition of these guidelines, quality control relates to seven different domains: (1) establishing centers with a sufficient number of sufficiently and specifically trained personnel, (2) minimum technical standards and equipment, (3) continuous medical education of employees, (4) surveillance by trained personnel during video electroencephalography (EEG) monitoring (VEM), (5) systematic acquisition of clinical and outcome data, (6) the minimum number of preoperative evaluations and epilepsy surgery procedures, and (7) the cooperation of epilepsy centers. These standards required the certification of the different professions involved and minimum numbers of procedures. In the subsequent decade, quite a number of colleagues were certified by the trinational WG; therefore, the executive board of the WG decided in 2013 to make these standards obligatory. This revised version is particularly relevant given that the German procedure classification explicitly refers to the guidelines of the WG with regard to noninvasive/invasive preoperative video-EEG monitoring and invasive intraoperative diagnostics in epilepsy. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.

  11. Guidelines for Remote Handling Maintenance of ITER Neutral Beam Components

    International Nuclear Information System (INIS)

    Cordier, J.-J.; Hemsworth, R.; Bayetti, P.

    2006-01-01

    Remote handling maintenance of ITER components is one of the main challenges of the ITER project. This type of maintenance shall be operational for the nuclear phase of exploitation of ITER, and be considered at a very early stage since it significantly impacts on the components design, interfaces management and integration business. A large part of the R/H equipment will be procured by the EU partner, in particular the whole Neutral Beam Remote Handling (RH) equipment package. A great deal of work has already been done in this field during the EDA phase of ITER project, but improvements and alternative option that are now proposed by ITER lead to added RH and maintenance engineering studies. The Neutral Beam Heating -and- Current Drive system 1 is being revisited by the ITER project. The vertical maintenance scheme that is presently considered by ITER, may significantly impact on the reference design of the Neutral Beam (NB) system and associated components and lead to new design of the NB box itself. In addition, revision of both NB cell radiation level zoning and remote handling classification of the beam line injector will also significantly impact on components design and maintenance. Based on the experience gained on the vertical maintenance scheme, developed in detail for the ITER Neutral Beam Test Facility 2 to be built in Europe in a near future, guidelines for the revision of the design and preliminary feasibility study of the remote handling vertical maintenance scheme of beam line components are described in the paper. A maintenance option for the SINGAP3 accelerator is also presented. (author)

  12. Low COST surgery setting for one-operational port laparoscopic hysterectomy surgery with ordinary laparoscopic instruments: preliminary results.

    Science.gov (United States)

    Limberger, Leo Francisco; Campos, Luciana Silveira; da Alves, Nilton Jacinto Rosa; Pedrini, Daniel Siqueira; de Limberger, Andiara Souza

    2013-10-02

    Hysterectomy dates back to 120BC and is the second most commonly performed gynecological surgery in the world. Cosmetic demands and the necessity of rapid return to work have contributed to the minimally invasive laparoscopic approach for hysterectomy. The majority of reports describe the use of three or four incisions to perform the surgery (two or three for manipulation and one for optics). This work describes our experience with using only two ports for 11 patients who underwent video-laparoscopic hysterectomy surgery. One port was used for the optical system, and the second was used for manipulation. Early and late surgery complications, as well as the time to return to work and daily activities, were assessed. The mean age of the patients was 41.4 years old (range 16 to 52 years) and the mean uterine weight was 133.54 g, ranging from 35 g and 291 g. The operative time ranged from 30 to 60 minutes (average 46.4 minutes) and the hospital stay ranged between 24 and 48 hrs. No intraoperative complications occurred, and no early or late postoperative complications were recorded. Patients reported minimal pain during the first 24-48 hrs in the hospital. Patients returned to their daily activities within seven days after surgery. Clinical care follow-up continued until the 40th postoperative day. The laparoscopic hysterectomy technique with a single port for manipulation is a feasible procedure when the uterine weight is not greater than 400 mg with little postoperative pain. The patients had an early return-to-work and daily activities and a better cosmetic outcome. These preliminary data led us to make the one-operative port laparoscopic hysterectomy the procedure of choice for patients with a low uterine weight.

  13. 36 CFR 1191.1 - Accessibility guidelines.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Accessibility guidelines... COMPLIANCE BOARD AMERICANS WITH DISABILITIES ACT (ADA) ACCESSIBILITY GUIDELINES FOR BUILDINGS AND FACILITIES; ARCHITECTURAL BARRIERS ACT (ABA) ACCESSIBILITY GUIDELINES § 1191.1 Accessibility guidelines. (a) The...

  14. Preliminary conceptual study of engineering-scale pyroprocess demonstration facility

    International Nuclear Information System (INIS)

    Moon, Seong-In; Chong, Won-Myung; You, Gil-Sung; Ku, Jeong-Hoe; Kim, Ho-Dong

    2013-01-01

    Highlights: ► The conceptual design of a pyroprocess demonstration facility was performed. ► The design requirements for the pyroprocess hot cell and equipment were determined. ► The maintenance concept for the pyroprocess hot cell was presented. -- Abstract: The development of an effective management technology of spent fuel is important to enhance environmental friendliness, cost viability and proliferation resistance. In Korea, pyroprocess technology has been considered as a fuel cycle option to solve the spent fuel accumulation problems. PRIDE (PyRoprocess Integrated inactive DEmonstration facility) has been developed from 2007 to 2012 in Korea as a cold test facility to support integrated pyroprocessing and an equipment demonstration, which is essential to verify the pyroprocess technology. As the next stage of PRIDE, the design requirements of an engineering-scale demonstration facility are being developed, and the preliminary conceptual design of the facility is being performed for the future. In this paper, the main design requirements for the engineering-scale pyroprocess demonstration facility were studied in the throughput of 10tHM a year. For the preliminary conceptual design of the facility, the design basis of the pyroprocess hot cell was suggested, and the main equipment, main process area, operation area, maintenance area, and so on were arranged in consideration of the effective operation of the hot cells. Also, the argon system was designed to provide and maintain a proper inert environment for the pyroprocess. The preliminary conceptual design data will be used to review the validity of the engineering-scale pyroprocess demonstration facility that enhances both safety and nonproliferation

  15. A critical appraisal of guidelines for the management of knee osteoarthritis using Appraisal of Guidelines Research and Evaluation criteria

    Science.gov (United States)

    Poitras, Stéphane; Avouac, Jérôme; Rossignol, Michel; Avouac, Bernard; Cedraschi, Christine; Nordin, Margareta; Rousseaux, Chantal; Rozenberg, Sylvie; Savarieau, Bernard; Thoumie, Philippe; Valat, Jean-Pierre; Vignon, Éric; Hilliquin, Pascal

    2007-01-01

    Clinical practice guidelines have been elaborated to summarize evidence related to the management of knee osteoarthritis and to facilitate uptake of evidence-based knowledge by clinicians. The objectives of the present review were summarizing the recommendations of existing guidelines on knee osteoarthritis, and assessing the quality of the guidelines using a standardized and validated instrument – the Appraisal of Guidelines Research and Evaluation (AGREE) tool. Internet medical literature databases from 2001 to 2006 were searched for guidelines, with six guidelines being identified. Thirteen clinician researchers participated in the review. Each reviewer was trained in the AGREE instrument. The guidelines were distributed to four groups of three or four reviewers, each group reviewing one guideline with the exception of one group that reviewed two guidelines. One independent evaluator reviewed all guidelines. All guidelines effectively addressed only a minority of AGREE domains. Clarity/presentation was effectively addressed in three out of six guidelines, scope/purpose and rigour of development in two guidelines, editorial independence in one guideline, and stakeholder involvement and applicability in none. The clinical management recommendation tended to be similar among guidelines, although interventions addressed varied. Acetaminophen was recommended for initial pain treatment, combined with exercise and education. Nonsteroidal anti-inflammatory drugs were recommended if acetaminophen failed to control pain, but cautiously because of gastrointestinal risks. Surgery was recommended in the presence of persistent pain and disability. Education and activity management interventions were superficially addressed in most guidelines. Guideline creators should use the AGREE criteria when developing guidelines. Innovative and effective methods of knowledge translation to health professionals are needed. PMID:18062805

  16. Preliminary report of an intervention to improve mammography skills of radiologists

    International Nuclear Information System (INIS)

    D'Orsi, C.J.; Karellas, A.; Costanza, M.E.; Gaw, V.P.

    1989-01-01

    This paper presents a preliminary report of an intervention to improve mammography skills of radiologists. Although implementation of the screening guidelines has not occurred as readily as had been anticipated, use of mammograms is increasing. As the demand for this relatively new technology increases, both the availability of the test and the quality of the test done are valid concerns. Until recently, few radiology training programs provided trainees with opportunities to develop these skills. As a result, few radiologists who have been in practice more than five years have had formal training in the interpretation of mammograms. Thus providing practicing radiologists with the opportunities to develop skills in mammographic interpretation will serve to increase both availability and quality of mammographic exams

  17. The Preliminary Decommissioning Plan of the Dalat Nuclear Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Lam, Pham Van; Vien, Luong Ba; Vinh, Le Vinh; Nghiem, Huynh Ton; Tuan, Nguyen Minh; Phuong, Pham Hoai [Nuclear Research Institute, Da Lat (Viet Nam)

    2013-08-15

    Recently, after 25 years of operation, a preliminary decommissioning plan for the Dalat Nuclear Research Reactor (DNRR) has been produced but as yet it has not been implemented due to the continued operations of the reactor. However, from the early phases of facility design and construction and during operation, the aspects that facilitate decommissioning process have been considered. This paper outlines the DNRR general description, the organization that manages the facility, the decommissioning strategy and associated project management, and the expected decommissioning activities. The paper also considers associated cost and funding, safety and environmental issues and waste management aspects amongst other considerations associated with decommissioning a nuclear research reactor. (author)

  18. Guidelines on Building Regulations 2008

    DEFF Research Database (Denmark)

    Thse guidelines clarify and intepret the provisions of the Building Regulations of 2008 (BR08). The Guidelines, which match BR08 in terms of organisation into Parts, are accompanied by the full text of the regulations and the explanatory notes issued by the Danish Enterprise and Construction...... Authority. The Guidelines refer the reader to sources such as relevant standards, instructions and other background material which provides more detailed information. The Guidelines cover the same ground as BR08, including building control regulations, layout, fitting out, structures, fire safety, indoor...... climate, energy consumotion and services. The Guidelines are aimed at all professionals involved in building projects, particularly building design consultants, contractors and municipal application officers....

  19. Managing challenging interactions with family caregivers in the cancer setting: Guidelines for clinicians (TRIO Guidelines-2).

    Science.gov (United States)

    Laidsaar-Powell, Rebekah; Butow, Phyllis; Boyle, Frances; Juraskova, Ilona

    2018-06-01

    Family caregivers can, at times, add complexity to clinical encounters. Difficult family caregivers and dynamics may: derail consultation communication, reduce patient autonomy, and compromise effective clinical care. A paucity of practical strategies guiding effective clinician-family communication exists. This study aimed to develop and evaluate the first comprehensive, evidence-based guidelines (the TRIO guidelines) for oncology physicians and nurses to better manage several complex/challenging situations involving family members. TRIO Guidelines were based on a comprehensive review of literature, relevant guidelines, and feedback from an expert advisory group (n = 10). Draft guidelines underwent two rounds of evaluation via an online Delphi consensus process involving international experts (n = 35). Guidelines incorporate topic areas, strategies, and sub-strategies on managing challenging family involvement (7 topics). Example wording, behaviours and level of evidence are provided. Challenging triadic interactions require skillful navigation, and the TRIO Guidelines provide clear, specific, and evidence-based strategies for clinicians to utilise in these potentially stressful encounters. Training based on these guidelines may improve both patient care and clinician confidence. Implementation of these guidelines into medical/nursing curricula and as a component of continuing professional development programs will likely be highly beneficial. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. The development and evaluation of guidelines for the review of advanced human-system interfaces

    International Nuclear Information System (INIS)

    O'Hara, J.M.; Wachtel, J.

    1992-01-01

    Advanced control rooms for future nuclear power plants are being designed utilizing computer-based technologies. The US Nuclear Regulatory Commission reviews the human engineering aspects of such control rooms to ensure that they are designed to good human factors engineering principles and that operator performance and reliability are appropriately supported in order to protect public health and safety. This paper describes a general approach to advanced human-system interface review, development of human factors guidelines to support NRC safety reviews of advanced systems, and the results of a guideline test and evaluation program

  1. Interim guidelines on performance constraints for nuclear waste disposal in crystalline rock

    International Nuclear Information System (INIS)

    1984-01-01

    Performance constraint guidelines have been developed for geologic disposal of nuclear waste in crystalline rock. The approach taken in defining these guidelines was to consider the thermal, thermomechanical, and thermochemical behavior for three regions (very-near field, near field, and far field) of the repository during three time periods (operational, containment, and isolation) associated with the disposal system. Limits are proposed to ensure compliance with the current repository criteria proposed by the United States Nuclear Regulatory Commission (NRC) concerning repository siting and performance assessment. These criteria are: Substantial containment of all radionuclides within the waste package for a period of time between 300 and 1000 years after emplacement. Release rate after loss of containment of one part in 100,000 annually per radionuclide based on the nuclides inventory when the waste package is breached, and in situ ground-water transit time of 1000 years from the repository horizon to the accessible environment, compliance with the performance constraint guidelines presented herein will be required to ensure that the final repository design is in compliance with NRC criteria. The constraint guidelines have also been developed to satisfy the requirement for technical conservatism. 40 refs., 14 figs., 4 tabs

  2. Evidence-based guidelines

    DEFF Research Database (Denmark)

    Rovira, Àlex; Wattjes, Mike P; Tintoré, Mar

    2015-01-01

    diagnosis in patients with MS. The aim of this article is to provide guidelines for the implementation of MRI of the brain and spinal cord in the diagnosis of patients who are suspected of having MS. These guidelines are based on an extensive review of the recent literature, as well as on the personal...

  3. Preliminary Results Of A 600 Joules Small Plasma Focus Device

    International Nuclear Information System (INIS)

    Lee, S. H.; Yap, S. L.; Wong, C. S.

    2009-01-01

    Preliminary results of a 600 J (3.7 μF, 18 kV) Mather type plasma focus device operated at low pressure will be presented. The discharge is formed between a solid anode with length of 6 cm and six symmetrically and coaxially arranged cathode rods of same lengths. The cathode base is profiled in a knife-edge design and a set of coaxial plasma gun are attached to it in order to initiate the breakdown and enhance the current sheath formation. The experiments have been performed in argon gas under a low pressure condition of several microbars. The discharge current and the voltage across the electrodes during the discharge are measured with high voltage probe and current coil. The current and voltage characteristics are used to determine the possible range of operating pressure that gives good focusing action. At a narrow pressure regime of 9.0±0.5 μbar, focusing action is observed with good reproducibility. Preliminary result of ion beam energy is presented. More work will be carried out to investigate the radiation output.

  4. Adopting preoperative fasting guidelines.

    Science.gov (United States)

    Anderson, Megan; Comrie, Rhonda

    2009-07-01

    In 1999, the American Society of Anesthesiologists adopted preoperative fasting guidelines to enhance the quality and efficiency of patient care. Guidelines suggest that healthy, non-pregnant patients should fast six hours from solids and two hours from liquids. Although these guidelines are in place, studies suggest that providers are still using the blanket statement "NPO after midnight" without regard to patient characteristics, the procedure, or the time of the procedure. Using theory to help change provider's beliefs may help make change more successful. Rogers' Theory of Diffusion of Innovations can assist in changing long-time practice by laying the groundwork for an analysis of the benefits and disadvantages of proposed changes, such as changes to fasting orders, while helping initiate local protocols instead of additional national guidelines.

  5. Optimum Operating Room Environment for the Prevention of Surgical Site Infections.

    Science.gov (United States)

    Gaines, Sara; Luo, James N; Gilbert, Jack; Zaborina, Olga; Alverdy, John C

    Surgical site infections (SSI), whether they be incisional or deep, can entail major morbidity and death to patients and additional cost to the healthcare system. A significant amount of effort has gone into optimizing the surgical patient and the operating room environment to reduce SSI. Relevant guidelines and literature were reviewed. The modern practice of surgical antisepsis involves the employment of strict sterile techniques inside the operating room. Extensive guidelines are available regarding the proper operating room antisepsis as well as pre-operative preparation. The use of pre-operative antimicrobial prophylaxis has become increasingly prevalent, which also presents the challenge of opportunistic and nosocomial infections. Ongoing investigative efforts have brought about a greater appreciation of the surgical patient's endogenous microflora, use of non-bactericidal small molecules, and pre-operative microbial screening. Systematic protocols exist for optimizing the surgical sterility of the operating room to prevent SSIs. Ongoing research efforts aim to improve the precision of peri-operative antisepsis measures and personalize these measures to tailor the patient's unique microbial environment.

  6. Selective nonoperative management of blunt splenic injury: an Eastern Association for the Surgery of Trauma practice management guideline.

    Science.gov (United States)

    Stassen, Nicole A; Bhullar, Indermeet; Cheng, Julius D; Crandall, Marie L; Friese, Randall S; Guillamondegui, Oscar D; Jawa, Randeep S; Maung, Adrian A; Rohs, Thomas J; Sangosanya, Ayodele; Schuster, Kevin M; Seamon, Mark J; Tchorz, Kathryn M; Zarzuar, Ben L; Kerwin, Andrew J

    2012-11-01

    During the last century, the management of blunt force trauma to the spleen has changed from observation and expectant management in the early part of the 1900s to mainly operative intervention, to the current practice of selective operative and nonoperative management. These issues were first addressed by the Eastern Association for the Surgery of Trauma (EAST) in the Practice Management Guidelines for Non-operative Management of Blunt Injury to the Liver and Spleen published online in 2003. Since that time, a large volume of literature on these topics has been published requiring a reevaluation of the current EAST guideline. The National Library of Medicine and the National Institute of Health MEDLINE database was searched using Pub Med (www.pubmed.gov). The search was designed to identify English-language citations published after 1996 (the last year included in the previous guideline) using the keywords splenic injury and blunt abdominal trauma. One hundred seventy-six articles were reviewed, of which 125 were used to create the current practice management guideline for the selective nonoperative management of blunt splenic injury. There has been a plethora of literature regarding nonoperative management of blunt splenic injuries published since the original EAST practice management guideline was written. Nonoperative management of blunt splenic injuries is now the treatment modality of choice in hemodynamically stable patients, irrespective of the grade of injury, patient age, or the presence of associated injuries. Its use is associated with a low overall morbidity and mortality when applied to an appropriate patient population. Nonoperative management of blunt splenic injuries should only be considered in an environment that provides capabilities for monitoring, serial clinical evaluations, and has an operating room available for urgent laparotomy. Patients presenting with hemodynamic instability and peritonitis still warrant emergent operative intervention

  7. Preliminary study on psychosomatic status of nuclear power plant operators

    International Nuclear Information System (INIS)

    Bi Jinling; Liu Yulong; Li Yuan; Bian Huahui; Sun Yiling; Qiu Mengyue; Liu Chunfeng

    2011-01-01

    Objective: To understand the operators' psychosomatic health status in nuclear power plant; and provide the scientific basis of measures for preventing and reducing mental disorders in operators. Methods: The Psychosomatic Health Battery (PSHB) was used to assess the psychosomatic health status in 109 operators who were random selected from Qinshan nuclear power plant, etc. They were tested from lie, emotional stability, liveliness, tension, apprehension, mental health, such as psychopathic deviatesuch 7 personality traits. Results: Lie < 8, all inspected groups were normal. Psychopathic deviate: 98.2% for normal group 0.9% for both of groups occurred possible mental health problems and confirmed mental health problems; Mental health: 80.7% (88/109) for fine mental health ones, 29.4% (32/109) for those with excellent mental health, 51.4% (56/109) for good mental health ones, 13.8% (15/109) for general mental health ones, 5.5% (6/109) for poor mental health ones. Age factor could influence the mean values of the factors of apprehension, tension, mental health and psychopathic deviate. Correlation analysis showed that there was a correlation between tension and psychopathic deviate (r=0.664, P<0.01), and the other correlation coefficient was between apprehension and mental health (r=-0.789, P<0.01). Conclusions: There is an excellent condition of psychosomatic health in most of the operators, however, there are still a very small percentage of psychosomatic disorders among these operators, to improve the quality of their psychosomatic health, psychological counseling should be particularly strengthened to those with problems of psychosomatic health. (authors)

  8. Common pitfalls to avoid during workover operations

    International Nuclear Information System (INIS)

    Byars, R.R.

    1994-01-01

    Remedial well work has been, and will continue to be, an integral part of oil company operations. More than 16,000 workover operations were performed during 1993 in the US. The economic impact from workover operations is usually immediate due to flowlines, tank batteries and other equipment being in place and ready for service prior to the workover. Similarly, problems encountered during workover operations contribute an immediate negative impact to project economics. Guidelines for common mistake avoidance are presented. They will be especially helpful for those individuals not well trained in workover preparation and supervision

  9. Virtual Chemical Engineering: Guidelines for E-Learning in Engineering Education

    Directory of Open Access Journals (Sweden)

    Damian Schofield

    2010-11-01

    Full Text Available Advanced three-dimensional virtual environment technology, similar to that used by the film and computer games industry can allow educational developers to rapidly create realistic three-dimensional, virtual environments. This technology has been used to generate a range of interactive learning environments across a broad spectrum of industries.The paper will discuss the implementation of these systems and extrapolate the lessons learnt into general guidelines to be considered for the development of a range of educational learning resources. These guidelines will then be discussed in the context of the development of ViRILE (Virtual Reality Interactive Learning Environment, software which simulates the configuration and operation of a polymerisation plant. This software package has been developed for use by undergraduate chemical engineers at the University of Nottingham.

  10. Methodological quality of guidelines in gastroenterology.

    Science.gov (United States)

    Malheiro, Rui; de Monteiro-Soares, Matilde; Hassan, Cesare; Dinis-Ribeiro, Mário

    2014-06-01

    Clinical guidelines are a common feature in modern endoscopy practice and they are being produced faster than ever. However, their methodological quality is rarely assessed. This study evaluated the methodological quality of current clinical guidelines in the field of gastroenterology, with an emphasis on endoscopy. Practice guidelines published by the American College of Gastroenterology (ACG), American Gastroenterological Association (AGA), American Society for Gastrointestinal Endoscopy (ASGE), European Society of Gastrointestinal Endoscopy (ESGE), British Society of Gastroenterology (BSG), National Institute for Health and Care Excellence (NICE), and the Scottish Intercollegiate Guidelines Network (SIGN) were searched between September and October 2012 and evaluated using the AGREE II (Appraisal of Guidelines for Research and Evaluation) instrument (23 items, scores 1 - 7 for each item; higher scores mean better quality). A total of 100 guidelines were assessed. The mean number of items scoring 6 or 7 per guideline was 9.2 (out of 23 items). Overall, 99 % of guidelines failed to include the target population in the development process, and 96 % did not report facilitators and barriers to guideline application. In addition, 86 % did not include advice or tools, and 94 % did not present monitoring or auditing criteria. The global methodological quality of clinical guidelines in the field of gastroenterology is poor, particularly regarding involvement of the target population in the development of guidelines and in the provision of clear suggestions to practitioners. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Guidelines for Waste Accumulation Areas (WAAs)

    International Nuclear Information System (INIS)

    1991-07-01

    The purpose of this document is to set conditions for establishing and maintaining areas for the accumulation of hazardous waste at LBL. Areas designed for accumulation of these wastes in quantities greater than 100 kg (220 lb) per month of solid waste or 55 gallons per month of liquid waste are called Waste Accumulation Areas (WAAs). Areas designed for accumulation of wastes in smaller amounts are called Satellite Accumulation Areas (SAAs). This document provides guidelines for employee and organizational responsibilities for WAAs; constructing a WAA; storing waste in a WAA; operating and maintaining a WAA, and responding to spills in a WAA. 4 figs

  12. Are BTS guidelines followed?

    Science.gov (United States)

    2002-03-01

    In 1993, the British Thoracic Society (BTS) issued guidelines for the management of spontaneous pneumothorax. The study's aim was to determine the level of adherence to these guidelines at a London teaching hospital. A retrospective case note audit of 59 episodes was performed. In patients undergoing intervention, the initial procedure was simple aspiration in 32 (73 per cent) and chest tube insertion in 12 (27 per cent) cases, contrasting with the BTS recommendation that aspiration should be attempted first in all such patients. Simple aspiration was successful on 34 per cent of occasions. Successful aspiration was associated with a significantly shorter hospital stay (median 3, range 1-11 days) than either failed aspiration (7, 3-66 days) or chest tube insertion without aspiration (9, 3-16 days). Other areas where practice differed from the BTS guidelines were clamping of chest tubes and use of a pursestring suture for wound closure. A follow up questionnaire suggested a lack of familiarity with the guidelines. These findings indicate that current management of spontaneous pneumothorax deviates from the BTS guidelines in potentially important respects.

  13. 36 CFR 910.67 - Square guidelines.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Square guidelines. 910.67... GUIDELINES AND UNIFORM STANDARDS FOR URBAN PLANNING AND DESIGN OF DEVELOPMENT WITHIN THE PENNSYLVANIA AVENUE DEVELOPMENT AREA Glossary of Terms § 910.67 Square guidelines. Square Guidelines establish the Corporation's...

  14. 28 CFR 2.36 - Rescission guidelines.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Rescission guidelines. 2.36 Section 2.36... guidelines. (a) The following guidelines shall apply to the sanctioning of disciplinary infractions or new... such period of confinement has resulted from initial parole to a detainer). These guidelines specify...

  15. Development of the Operational Events Groups Ranking Tool

    International Nuclear Information System (INIS)

    Simic, Zdenko; Banov, Reni

    2014-01-01

    Both because of complexity and ageing, facilities like nuclear power plants require feedback from the operating experience in order to further improve safety and operation performance. That is the reason why significant effort is dedicated to operating experience feedback. This paper contains description of the specification and development of the application for the operating events ranking software tool. Robust and consistent way of selecting most important events for detail investigation is important because it is not feasible or even useful to investigate all of them. Development of the tool is based on the comprehensive events characterisation and methodical prioritization. This includes rich set of events parameters which allow their top level preliminary analysis, different ways of groupings and even to evaluate uncertainty propagation to the ranking results. One distinct feature of the implemented method is that user (i.e., expert) could determine how important is particular ranking parameter based on their pairwise comparison. For tools demonstration and usability it is crucial that sample database is also created. For useful analysis the whole set of events for 5 years is selected and characterised. Based on the preliminary results this tool seems valuable for new preliminary prospective on data as whole, and especially for the identification of events groups which should have priority in the more detailed assessment. The results are consisting of different informative views on the events groups importance and related sensitivity and uncertainty results. This presents valuable tool for improving overall picture about specific operating experience and also for helping identify the most important events groups for further assessment. It is clear that completeness and consistency of the input data characterisation is very important to get full and valuable importance ranking. Method and tool development described in this paper is part of continuous effort of

  16. Preliminary seismicity and focal mechanisms for the southern Great Basin of Nevada and California: January 1992 through September 1992

    International Nuclear Information System (INIS)

    Harmsen, S.C.

    1994-01-01

    The telemetered southern Great Basin seismic network (SGBSN) is operated for the Department of Energy's Yucca Mountain Project (YMP). The US Geological Survey, Branch of Earthquake and Landslide Hazards, maintained this network until September 30, 1992, at which time all operational and analysis responsibilities were transferred to the University of Nevada at Reno Seismological Laboratory (UNRSL). This report contains preliminary earthquake and chemical explosion hypocenter listings and preliminary earthquake focal mechanism solutions for USGS/SGBSN data for the period January 1, 1992 through September 30, 1992, 15:00 UTC

  17. 23 CFR 650.211 - Guidelines.

    Science.gov (United States)

    2010-04-01

    ... 23 Highways 1 2010-04-01 2010-04-01 false Guidelines. 650.211 Section 650.211 Highways FEDERAL..., STRUCTURES, AND HYDRAULICS Erosion and Sediment Control on Highway Construction Projects § 650.211 Guidelines. (a) The FHWA adopts the AASHTO Highway Drainage Guidelines, Volume III, “Erosion and Sediment Control...

  18. 15 CFR 1170.4 - Guidelines.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 3 2010-01-01 2010-01-01 false Guidelines. 1170.4 Section 1170.4... ADMINISTRATION, DEPARTMENT OF COMMERCE METRIC CONVERSION POLICY FOR FEDERAL AGENCIES § 1170.4 Guidelines. Each... agency actions, activities or programs undertaken in compliance with these guidelines or other laws or...

  19. ESUR prostate MR guidelines 2012

    DEFF Research Database (Denmark)

    Barentsz, Jelle O; Richenberg, Jonathan; Clements, Richard

    2012-01-01

    The aim was to develop clinical guidelines for multi-parametric MRI of the prostate by a group of prostate MRI experts from the European Society of Urogenital Radiology (ESUR), based on literature evidence and consensus expert opinion. True evidence-based guidelines could not be formulated......, but a compromise, reflected by "minimal" and "optimal" requirements has been made. The scope of these ESUR guidelines is to promulgate high quality MRI in acquisition and evaluation with the correct indications for prostate cancer across the whole of Europe and eventually outside Europe. The guidelines...... provides guidelines for magnetic resonance imaging (MRI) in prostate cancer. Clinical indications, and minimal and optimal imaging acquisition protocols are provided. A structured reporting system (PI-RADS) is described....

  20. Radiological risk guidelines for nonreactor nuclear facilities at the Pacific Northwest Laboratory

    International Nuclear Information System (INIS)

    Lucas, D.E.; Ikenberry, T.A.

    1993-09-01

    Radiological risk evaluation guidelines for the public and workers have been developed at the Pacific Northwest Laboratory (PNL) based upon the Nuclear Safety Policy of the US Department of Energy (DOE) established in Secretary of Energy Notice SEN-35-91. The DOE nuclear safety policy states that the general public shall be protected such that no individual bears significant additional risk to health and safety from the operation of a DOE nuclear facility above the risks to which members of the general population are normally exposed. The radiological risk evaluation guidelines developed at PNL are unique in that they are (1) based upon quantitative risk goals and (2) provide a consistent level of risk management. These guidelines are used to evaluate the risk from radiological accidents that may occur during research and development activities at PNL, and are not intended for evaluation of routine exposures. A safety analyst uses the,frequency of the potential accident and the radiological dose to a given receptor to determine if the accident consequences meet the objectives of the Nuclear Safety Policy. The radiological risk evaluation guidelines are an effective tool for assisting in the management of risk at DOE nonreactor nuclear facilities. These guidelines (1) meet the nuclear safety policy of DOE, (2) establish a tool for managing risk at a consistent level within the defined constraints, and (3) set risk at an appropriate level, as compared with other risks encountered by the public and worker. Table S.1 summarizes the guidelines developed in this report