WorldWideScience

Sample records for preliminary imaging results

  1. Preliminary Results Of PCA On MRO CRISM Multispectral Images

    Science.gov (United States)

    Klassen, David R.; Smith, M. D.

    2008-09-01

    Mars Reconnaissance Orbiter arrived at Mars in March 2006 and by September had achieved its science-phase orbit with the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) beginning its visible to near-infrared (VIS/NIR) spectral imaging shortly thereafter. One of the goals of CRISM is to fill in the spatial gaps between the various targeted observations, eventually mapping the entire surface. Due to the large volume of data this would create, the instrument works in a reduced spectral sampling mode creating "multispectral” images. From this data we can create image cubes using 70 wavelengths from 0.410 to 3.504 µm. We present here a preliminary analysis of these multispectral mode data products using the technique of Principal Components Analysis. Previous work with ground-based images has shown that over an entire visible hemisphere, there are only three to four meaningful components out of 32-105 wavelengths over 1.5-4.1 µm. The first two of these components are fairly consistent over all time intervals from day-to-day and season-to-season. [1-4] The preliminary work on the CRISM images cubes implies similar results_three to four significant principal components that are fairly consistent over time. We will show these components and a rough linear mixture modeling based on in-data spectral endmembers derived from the extrema of the principal components [5]. References: [1] Klassen, D. R. and Bell III, J. F. (2001) BAAS 33, 1069. [2] Klassen, D. R. and Bell III, J. F. (2003) BAAS, 35, 936. [3] Klassen, D. R., Wark, T. J., Cugliotta, C. G. (2005) BAAS, 37, 693. [4] Klassen, D. R. and Bell III, J. F. (2007) in preparation. [5] Klassen, D. R. and Bell III, J. F. (2000) BAAS, 32, 1105.

  2. Preliminary results of MR imaging of lymphoma: Distinguishing active tumor from benign residue

    International Nuclear Information System (INIS)

    Drace, J.; Baker, L.L.; Chang, P.; Castellino, R.A.

    1987-01-01

    Distinguishing tumor from benign posttreatment tissue based on both morphologic and tissue characteristics is critically important. Patients are studied before, during, and after treatment; at the time of recurrence; and on long-term follow-up. Multisection spin-echo sequences in orthogonal planes and a special single-section tissue characterization matrix of 16 different repetition time/echo time combinations are used. These basic images are used for cluster analysis (approximate fuzzy C means), T1-T2 synthetic images, linear combinations, and comparison with internal standards. Preliminary results in 35 patients imaged before treatment and 12 patients with follow-up examinations consistently show lymphoma masses to have complex architecture with high T2-weighted signal and moderate T1-weighted signal, distinct from posttreatment fibrosis. Uncommon components of active tumor with low T2-weighted signal appear distinct from fibrosis on T1-weighted images. Preliminary cluster analysis results show distinct clustering of active lymphoma versus fibrosis and biopsy-proved cystic degeneration

  3. Magnetic resonance imaging of the brain in neonates. Preliminary results

    International Nuclear Information System (INIS)

    Dumoulin, M.; Legrand, M.; Gremillet, C.; Lecouffe, P.; Rousseau, J.; Pruvo, J.P.; Marchandise, X.

    1991-01-01

    The place of neonatal cerebral MRI and its specific contribution compared with conventional imaging techniques were evaluated in 36 patients. The difficulties specific to the patient population studied met during this preliminary period are described, with their local solutions. A preliminary evaluation of the diagnostic and prognostic value of MRI according to the disease state and gestational age is presented. The specific contribution of MRI compared with transfontanellar ultrasonography and CT scan is discussed [fr

  4. Preliminary results on tests of a Cerenkov ring imaging device employing a photoionizing PWC

    Energy Technology Data Exchange (ETDEWEB)

    Durkin, S.; Honma, A.; Leith, D.W.G.S.

    1978-08-01

    A brief description of techniques and problems of ring imaging Cerenkov detectors employing photoionizing PWC's is discussed. Preliminary results on a one dimensional ring imaging device tested at SLAC in May and June of 1978 are then presented. These results include rough measurements of the Cerenkov ring in nitrogen, argon, neon, and helium produced by a collimated positron beam.

  5. Preliminary PCA/TT Results on MRO CRISM Multispectral Images

    Science.gov (United States)

    Klassen, David R.; Smith, M. D.

    2010-10-01

    Mars Reconnaissance Orbiter arrived at Mars in March 2006 and by September had achieved its science-phase orbit with the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) beginning its visible to near-infrared (VIS/NIR) spectral imaging shortly thereafter. One goal of CRISM is to fill in the spatial gaps between the various targeted observations, eventually mapping the entire surface. Due to the large volume of data this would create, the instrument works in a reduced spectral sampling mode creating "multispectral” images. From these data we can create image cubes using 64 wavelengths from 0.410 to 3.923 µm. We present here our analysis of these multispectral mode data products using Principal Components Analysis (PCA) and Target Transformation (TT) [1]. Previous work with ground-based images [2-5] has shown that over an entire visible hemisphere, there are only three to four meaningful components using 32-105 wavelengths over 1.5-4.1 µm the first two are consistent over all temporal scales. The TT retrieved spectral endmembers show nearly the same level of consistency [5]. The preliminary work on the CRISM images cubes implies similar results; three to four significant principal components that are fairly consistent over time. These components are then used in TT to find spectral endmembers which can be used to characterize the surface reflectance for future use in radiative transfer cloud optical depth retrievals. We present here the PCA/TT results comparing the principal components and recovered endmembers from six reconstructed CRISM multi-spectral image cubes. References: [1] Bandfield, J. L., et al. (2000) JGR, 105, 9573. [2] Klassen, D. R. and Bell III, J. F. (2001) BAAS 33, 1069. [3] Klassen, D. R. and Bell III, J. F. (2003) BAAS, 35, 936. [4] Klassen, D. R., Wark, T. J., Cugliotta, C. G. (2005) BAAS, 37, 693. [5] Klassen, D. R. (2009) Icarus, 204, 32.

  6. Preliminary results from a novel CVD diamond detector system for molecular imaging applications

    International Nuclear Information System (INIS)

    Mahon, A.R.

    1996-01-01

    A novel biomolecular imaging system incorporating a Chemical Vapour Deposition diamond detector is in development. The synthetic diamond is used as a UV detector to image nucleic acids in electrophoresis gels. The microstrip diamond detector currently has a spatial resolution of 30 μm. Preliminary results are presented which include: QE measurements of diamond detectors, detector time response, detector UV response and current detection limits of biomolecules in gel. The potential applications of the technology, and its significant advantages in speed and sensitivity over the current systems are discussed

  7. Triangular SPECT system for 3-D total organ volume imaging: Design concept and preliminary imaging results

    International Nuclear Information System (INIS)

    Lim, C.B.; Anderson, J.; Covic, J.

    1985-01-01

    SPECT systems based on 2-D detectors for projection data collection and filtered back-projection image reconstruction have the potential for true 3-D imaging, providing contiguous slice images in any orientation. Anger camera-based SPECT systems have the natural advantage supporting planar imaging clinical procedures. However, current systems suffer from two drawbacks; poor utilization of emitted photons, and inadequate system design for SPECT. A SPECT system consisting of three rectangular cameras with radial translation would offer the variable cylindrical FOV of 25 cm to 40 cm diameter allowing close detector access to the object. This system would provide optimized imaging for both brain and body organs in terms of sensitivity and resolution. For brain imaging a tight detector triangle with fan beam collimation, matching detector UFOV to the head, allows full 2 π utilization of emitted photons, resulting in >4 times sensitivity increase over the single detector system. Minification of intrinsic detector resolution in fan beam collimation further improves system resolution. For body organ imaging the three detectors with parallel hole collimators, rotating in non-circular orbit, provide both improved resolution and three-fold sensitivity increase. Practical challenges lie in ensuring perfect image overlap from three detectors without resolution degradation and artifact generation in order to benefit from the above improvements. An experimental system has been developed to test the above imaging concept and we have successfully demonstrated the superior image quality of the overlapped images. Design concept will be presented with preliminary imaging results

  8. Preliminary Results of Clover and Grass Coverage and Total Dry Matter Estimation in Clover-Grass Crops Using Image Analysis

    Directory of Open Access Journals (Sweden)

    Anders K. Mortensen

    2017-12-01

    Full Text Available The clover-grass ratio is an important factor in composing feed ratios for livestock. Cameras in the field allow the user to estimate the clover-grass ratio using image analysis; however, current methods assume the total dry matter is known. This paper presents the preliminary results of an image analysis method for non-destructively estimating the total dry matter of clover-grass. The presented method includes three steps: (1 classification of image illumination using a histogram of the difference in excess green and excess red; (2 segmentation of clover and grass using edge detection and morphology; and (3 estimation of total dry matter using grass coverage derived from the segmentation and climate parameters. The method was developed and evaluated on images captured in a clover-grass plot experiment during the spring growing season. The preliminary results are promising and show a high correlation between the image-based total dry matter estimate and the harvested dry matter ( R 2 = 0.93 with an RMSE of 210 kg ha − 1 .

  9. Imaging-based surrogate markers of transcriptome subclasses and signatures in hepatocellular carcinoma. Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Taouli, Bachir [Icahn School of Medicine at Mount Sinai, Department of Radiology, New York, NY (United States); Icahn School of Medicine at Mount Sinai, Translational and Molecular Imaging Institute, New York, NY (United States); Icahn School of Medicine at Mount Sinai, Liver Cancer Program, Tisch Cancer Institute, New York, NY (United States); Hoshida, Yujin; Chen, Xintong; Sun, Xiaochen; Kojima, Kensuke; Toffanin, Sara; Hirschfield, Hadassa [Icahn School of Medicine at Mount Sinai, Liver Cancer Program, Tisch Cancer Institute, New York, NY (United States); Icahn School of Medicine at Mount Sinai, Division of Liver Diseases, Department of Medicine, New York, NY (United States); Kakite, Suguru [Icahn School of Medicine at Mount Sinai, Translational and Molecular Imaging Institute, New York, NY (United States); Tottori University, Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Yonago City (Japan); Tan, Poh Seng [Icahn School of Medicine at Mount Sinai, Liver Cancer Program, Tisch Cancer Institute, New York, NY (United States); Icahn School of Medicine at Mount Sinai, Division of Liver Diseases, Department of Medicine, New York, NY (United States); National University Health System, Division of Gastroenterology and Hepatology, University Medicine Cluster, Singapore (Singapore); Kihira, Shingo [Icahn School of Medicine at Mount Sinai, Department of Radiology, New York, NY (United States); Fiel, M.I. [Icahn School of Medicine at Mount Sinai, Department of Pathology, New York, NY (United States); Wagner, Mathilde [Icahn School of Medicine at Mount Sinai, Translational and Molecular Imaging Institute, New York, NY (United States); Sorbonne Universites, UPMC, Department of Radiology, Hopital Pitie-Salpetriere, Paris (France); Llovet, Josep M. [Icahn School of Medicine at Mount Sinai, Liver Cancer Program, Tisch Cancer Institute, New York, NY (United States); Icahn School of Medicine at Mount Sinai, Division of Liver Diseases, Department of Medicine, New York, NY (United States); Universitat de Barcelona, HCC Translational Research Laboratory, Barcelona-Clinic Liver Cancer Group Institut d' Investigacions Biomediques August Pi i Sunyer (IDIBAPS), Hospital Clinic de Barcelona, Barcelona (Spain); Institucio Catalana de Recerca i Estudis Avancats, Barcelona (Spain)

    2017-11-15

    In this preliminary study, we examined whether imaging-based phenotypes are associated with reported predictive gene signatures in hepatocellular carcinoma (HCC). Thirty-eight patients (M/F 30/8, mean age 61 years) who underwent pre-operative CT or MR imaging before surgery as well as transcriptome profiling were included in this IRB-approved single-centre retrospective study. Eleven qualitative and four quantitative imaging traits (size, enhancement ratios, wash-out ratio, tumour-to-liver contrast ratios) were assessed by three observers and were correlated with 13 previously reported HCC gene signatures using logistic regression analysis. Thirty-nine HCC tumours (mean size 5.7 ± 3.2 cm) were assessed. Significant positive associations were observed between certain imaging traits and gene signatures of aggressive HCC phenotype (G3-Boyault, Proliferation-Chiang profiles, CK19-Villanueva, S1/S2-Hoshida) with odds ratios ranging from 4.44-12.73 (P <0.045). Infiltrative pattern at imaging was significantly associated with signatures of microvascular invasion and aggressive phenotype. Significant but weak associations were also observed between each enhancement ratio and tumour-to-liver contrast ratios and certain gene expression profiles. This preliminary study demonstrates a correlation between phenotypic imaging traits with gene signatures of aggressive HCC, which warrants further prospective validation to establish imaging-based surrogate markers of molecular phenotypes in HCC. (orig.)

  10. Imaging-based surrogate markers of transcriptome subclasses and signatures in hepatocellular carcinoma. Preliminary results

    International Nuclear Information System (INIS)

    Taouli, Bachir; Hoshida, Yujin; Chen, Xintong; Sun, Xiaochen; Kojima, Kensuke; Toffanin, Sara; Hirschfield, Hadassa; Kakite, Suguru; Tan, Poh Seng; Kihira, Shingo; Fiel, M.I.; Wagner, Mathilde; Llovet, Josep M.

    2017-01-01

    In this preliminary study, we examined whether imaging-based phenotypes are associated with reported predictive gene signatures in hepatocellular carcinoma (HCC). Thirty-eight patients (M/F 30/8, mean age 61 years) who underwent pre-operative CT or MR imaging before surgery as well as transcriptome profiling were included in this IRB-approved single-centre retrospective study. Eleven qualitative and four quantitative imaging traits (size, enhancement ratios, wash-out ratio, tumour-to-liver contrast ratios) were assessed by three observers and were correlated with 13 previously reported HCC gene signatures using logistic regression analysis. Thirty-nine HCC tumours (mean size 5.7 ± 3.2 cm) were assessed. Significant positive associations were observed between certain imaging traits and gene signatures of aggressive HCC phenotype (G3-Boyault, Proliferation-Chiang profiles, CK19-Villanueva, S1/S2-Hoshida) with odds ratios ranging from 4.44-12.73 (P <0.045). Infiltrative pattern at imaging was significantly associated with signatures of microvascular invasion and aggressive phenotype. Significant but weak associations were also observed between each enhancement ratio and tumour-to-liver contrast ratios and certain gene expression profiles. This preliminary study demonstrates a correlation between phenotypic imaging traits with gene signatures of aggressive HCC, which warrants further prospective validation to establish imaging-based surrogate markers of molecular phenotypes in HCC. (orig.)

  11. Preliminary Results of Nuclear Fluorescence Imaging of Alpha and Beta Emitting Sources

    International Nuclear Information System (INIS)

    Feener, Jessica S.; Charlton, William S.

    2013-06-01

    The preliminary results from a series of nuclear fluorescence imaging experiments using a variety of radioactive sources and shielding are given. These experiments were done as part of a proof of concept to determine if nuclear fluorescence imaging could be used as a safeguards measurements tool or for nuclear warhead verification for nuclear arms control treaties such as the New Strategic Arms Reduction Treaty and the Fissile Material Cut-Off Treaty. An off-the-shelf Princeton Instruments charged coupled device camera system was used to image the emission of fluorescence photons from the de-excitation of nitrogen molecules in air that have been excited by ionizing radiation. The fluorescence emissions are primarily in the near ultraviolet range; between the wavelengths of 300 and 400 nm. Fluorescent imaging techniques are currently being investigated in a number of applications. A French research team has successfully demonstrated this concept for remote imaging of alpha contamination. It has also been shown that the phenomenon can be seen through translucent materials and that alpha radiation can be seen in the presence of large gamma backgrounds. Additionally, fluorescence telescopes and satellites utilize the de-excitation of nitrogen molecules to observe cosmic ray showers in the atmosphere. In cosmic ray shower detection, electrons are the main contributor to the excitation of the of nitrogen molecules in air. The experiments presented in this paper were designed to determine if the imaging system could observe beta emitting sources, differentiate between beta emitters and alpha emitting materials such as uranium oxide and uranium metal, and to further investigate the phenomenon through translucent and non-translucent materials. The initial results show that differentiation can be made between beta and alpha emitting sources and that the device can observe the phenomenon through very thin non-transparent material. Additionally, information is given on the

  12. Fast, free-breathing, in vivo fetal imaging using time-resolved 3D MRI technique: preliminary results.

    Science.gov (United States)

    Liu, Jing; Glenn, Orit A; Xu, Duan

    2014-04-01

    Fetal MR imaging is very challenging due to the movement of fetus and the breathing motion of the mother. Current clinical protocols involve quick 2D scouting scans to determine scan plane and often several attempts to reorient the scan plane when the fetus moves. This makes acquisition of fetal MR images clinically challenging and results in long scan times in order to obtain images that are of diagnostic quality. Compared to 2D imaging, 3D imaging of the fetus has many advantages such as higher SNR and ability to reformat images in multiple planes. However, it is more sensitive to motion and challenging for fetal imaging due to irregular fetal motion in addition to maternal breathing and cardiac motion. This aim of this study is to develop a fast 3D fetal imaging technique to resolve the challenge of imaging the moving fetus. This 3D imaging sequence has multi-echo radial sampling in-plane and conventional Cartesian encoding through plane, which provides motion robustness and high data acquisition efficiency. The utilization of a golden-ratio based projection profile allows flexible time-resolved image reconstruction with arbitrary temporal resolution at arbitrary time points as well as high signal-to-noise and contrast-to-noise ratio. The nice features of the developed image technique allow the 3D visualization of the movements occurring throughout the scan. In this study, we applied this technique to three human subjects for fetal MRI and achieved promising preliminary results of fetal brain, heart and lung imaging.

  13. TREE STEM RECONSTRUCTION USING VERTICAL FISHEYE IMAGES: A PRELIMINARY STUDY

    Directory of Open Access Journals (Sweden)

    A. Berveglieri

    2016-06-01

    Full Text Available A preliminary study was conducted to assess a tree stem reconstruction technique with panoramic images taken with fisheye lenses. The concept is similar to the Structure from Motion (SfM technique, but the acquisition and data preparation rely on fisheye cameras to generate a vertical image sequence with height variations of the camera station. Each vertical image is rectified to four vertical planes, producing horizontal lateral views. The stems in the lateral view are rectified to the same scale in the image sequence to facilitate image matching. Using bundle adjustment, the stems are reconstructed, enabling later measurement and extraction of several attributes. The 3D reconstruction was performed with the proposed technique and compared with SfM. The preliminary results showed that the stems were correctly reconstructed by using the lateral virtual images generated from the vertical fisheye images and with the advantage of using fewer images and taken from one single station.

  14. A comparison of gallium-67 citrate scintigraphy and indium-111 labelled leukocyte imaging for the diagnosis of prosthetic joint infection. Preliminary results

    International Nuclear Information System (INIS)

    McKillop, J.H.; Cuthbert, G.F.; Gray, H.W.; McKay, Iain; Sturrock, R.D.

    1982-01-01

    Preliminary experience in comparing Gallium-67 imaging in patients with a painful prosthetic joint to the findings on Indium-111 labelled leukocyte imaging is reported. In the small series of patients so far studied, no clear advantage has emerged for either Gallium-67 or Indium-111 leukocyte imaging in terms of sensitivity or specificity for joint prosthesis infection. Should a larger group confirm the preliminary findings, Gallium-67 imaging may be preferable to Indium-111 leukocyte imaging in the patient with the painful joint prosthesis, in view of the greater simplicity of the former technique

  15. Preliminary results for X-ray phase contrast micro-tomography on the biomedical imaging beamline at SSRF

    International Nuclear Information System (INIS)

    Chen Rongchang; Du Guohao; Xie Honglan; Deng Biao; Tong Yajun; Hu Wen; Xue Yanling; Chen Can; Ren Yuqi; Zhou Guangzhao; Wang Yudan; Xiao Tiqiao; Xu Hongjie; Zhu Peiping

    2009-01-01

    With X-ray phase contrast micro-tomography(CT), one is able to obtain edge-enhanced image of internal structure of the samples. This allows visualization of the fine internal features for biology tissues, which is not able to resolve by conventional absorption CT. After preliminary modulation, monochromatic X-rays (8-72.5 keV) are available for experiments on the experimental station of the biomedical imaging beamline at Shanghai Synchrotron Radiation Facility(SSRF). In this paper, we report the in line phase contrast micro-tomography(IL-XPCT) of biology sample (locust) on the beamline. The reconstruct slice images and three dimensional rendering images of the locust were obtained, with clearly visible images of locus's wing, surface texture and internal tissue distribution. (authors)

  16. Biological image construction by using Raman radiation and Pca: preliminary results

    International Nuclear Information System (INIS)

    Martinez E, J. C.; Cordova F, T.; Hugo R, V.

    2015-10-01

    Full text: In the last years, the Raman spectroscopy (Rs) technique has had some applications in the study and analysis of biological samples, due to it is able to detect concentrations or presence of certain organic and inorganic compounds of medical interest. In this work, raw data were obtained through measurements in selected points on a square regions in order to detect specific organic / inorganic compounds on biological samples. Gold nano stars samples were prepared and coated with membrane markers (CD 10+ and CD 19+) and diluted in leukemic B lymphocytes. Each data block was evaluated independently by the method of principal component analysis (Pca) in order to find representative dimensionless values (Cp) for each Raman spectrum in a specific coordinate. Each Cp was normalized in a range of 0-255 in order to generate a representative image of 8 bits of the region under study. Data acquisition was performed with Raman microscopy system Renishaw in Via in the range of 550 to 1700 cm-1 with a 785 nm laser source, with a power of 17 m W and 15 s of exposure time were used for each spectrum. In preliminary results could detect the presence of molecular markers CD 10+ and CD 19+ with gold nano stars and discrimination between both markers. The results suggest conducting studies with specific concentrations organic and inorganic materials. (Author)

  17. Biological image construction by using Raman radiation and Pca: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Martinez E, J. C. [IPN, Unidad Profesional Interdisciplinaria de Ingenieria, Campus Guanajuato, Av. Mineral de Valenciana 200, Col. Fracc. Industrial Puerto Interior, 36275 Silao, Guanajuato (Mexico); Cordova F, T. [Universidad de Guanajuato, DIC, Departamento de Ingenieria Fisica, Loma del Bosque No. 103, Col. Lomas del Campestre, 37150 Leon, Guanajuato (Mexico); Hugo R, V., E-mail: jcmartineze@ipn.mx [Universidad de Guadalajara, Centro Universitario de Tonala, Morelos No. 180, 69584 Tonala, Jalisco (Mexico)

    2015-10-15

    Full text: In the last years, the Raman spectroscopy (Rs) technique has had some applications in the study and analysis of biological samples, due to it is able to detect concentrations or presence of certain organic and inorganic compounds of medical interest. In this work, raw data were obtained through measurements in selected points on a square regions in order to detect specific organic / inorganic compounds on biological samples. Gold nano stars samples were prepared and coated with membrane markers (CD 10+ and CD 19+) and diluted in leukemic B lymphocytes. Each data block was evaluated independently by the method of principal component analysis (Pca) in order to find representative dimensionless values (Cp) for each Raman spectrum in a specific coordinate. Each Cp was normalized in a range of 0-255 in order to generate a representative image of 8 bits of the region under study. Data acquisition was performed with Raman microscopy system Renishaw in Via in the range of 550 to 1700 cm-1 with a 785 nm laser source, with a power of 17 m W and 15 s of exposure time were used for each spectrum. In preliminary results could detect the presence of molecular markers CD 10+ and CD 19+ with gold nano stars and discrimination between both markers. The results suggest conducting studies with specific concentrations organic and inorganic materials. (Author)

  18. Predicting visual semantic descriptive terms from radiological image data: preliminary results with liver lesions in CT.

    Science.gov (United States)

    Depeursinge, Adrien; Kurtz, Camille; Beaulieu, Christopher; Napel, Sandy; Rubin, Daniel

    2014-08-01

    We describe a framework to model visual semantics of liver lesions in CT images in order to predict the visual semantic terms (VST) reported by radiologists in describing these lesions. Computational models of VST are learned from image data using linear combinations of high-order steerable Riesz wavelets and support vector machines (SVM). In a first step, these models are used to predict the presence of each semantic term that describes liver lesions. In a second step, the distances between all VST models are calculated to establish a nonhierarchical computationally-derived ontology of VST containing inter-term synonymy and complementarity. A preliminary evaluation of the proposed framework was carried out using 74 liver lesions annotated with a set of 18 VSTs from the RadLex ontology. A leave-one-patient-out cross-validation resulted in an average area under the ROC curve of 0.853 for predicting the presence of each VST. The proposed framework is expected to foster human-computer synergies for the interpretation of radiological images while using rotation-covariant computational models of VSTs to 1) quantify their local likelihood and 2) explicitly link them with pixel-based image content in the context of a given imaging domain.

  19. Preliminary results for positron emission mammography: real-time functional breast imaging in a conventional mammography gantry

    International Nuclear Information System (INIS)

    Weinberg, I.; Majewski, S.; Weisenberger, A.; Markowitz, A.; Aloj, L.; Majewski, L,; Danforth, D.; Mulshine, J.; Cowan, K.; Zujewski, J.; Chow, C.; Jones, E.; Chang, V.; Berg, W.; Frank, J.

    1996-01-01

    In order to optimally integrate radiotracer breast imaging within the breast clinic, anatomy and pathology should be easily correlated with functional nuclear medicine breast images. As a first step in the development of a hybrid functional/anatomic breast imaging platform with biopsy capability, a conventional X-ray mammography gantry was modified to image the compressed brest with positron emitters. Phantom studies with the positron emission mammography (PEM) device showed that a 1-cc hot spot could be detected within 5 min. A preliminary clinical trial demonstrated in vivo visualization of primary breast cancer within 4 min. For sites where positron-emitting radionuclides are available, PEM promises to achieve low-cost directed functional examination of breast abnormalities, with potential for achieving X-ray correlation and image-guided biopsy. (orig.)

  20. Cognitive impairment and computer tomography image in patients with arterial hypertension -preliminary results

    International Nuclear Information System (INIS)

    Yaneva-Sirakova, T.; Tarnovska-Kadreva, R.; Traykov, L.; Zlatareva, D.

    2012-01-01

    Arterial hypertension is the leading risk factor for cognitive impairment, but it is developed only in some of the patients with pour control. On the other hand, not all of the patents with white matter changes have cognitive deficit. There may be a variety of reasons for this: the accuracy of methods for blood pressure measurement, the specific brain localization or some other reason. Here are the preliminary results of a study (or the potential correlation between self-measured, office-, ambulatory monitored blood pressure, central aortic blood pressure, minimal cognitive impairment and the specific brain image on contrast computer tomography. We expect to answer, the question whether central aortic or self-measured blood pressure have the leading role for the development of cognitive impairment in the presence of a specific neuroimaging finding, as well as what is the prerequisite for the clinical manifestation of cognitive dysfunction in patients with computer tomographic pathology. (authors)

  1. Dynamic gadolinium-enhanced subtraction MR imaging - a simple technique for the early diagnosis of Legg-Calve-Perthes disease: preliminary results

    International Nuclear Information System (INIS)

    Sebag, G.; Ducou Le Pointe, H.; Klein, I.; Maiza, D.; Mazda, K.; Bensahel, H.; Hassan, M.

    1997-01-01

    To determine whether the simple technique of dynamic gadolinium-enhanced subtraction MR imaging, which is available on standard MR units, can detect ischemia of the femoral head in children with early Legg-Calve-Perthes disease (LCP). Bone perfusion of eight hips in four patients (mean age 7.5 years) was studied using dynamic gadolinium-enhanced substraction MR imaging at the onset of proven LCP (with initial negative plain films). Enhancement of subtracted images was compared with that on standard MR images and with bone scintigraphy findings. Subtraction MR imaging depicted ischemia as a widespread absence of enhancement and was in good agreement with bone scintigraphy. The subtraction technique improved the sensitivity and the specificity of MR imaging in two children. Furthermore, subtraction MR imaging allowed recognition of the pattern of early reperfusion. Our preliminary results indicate that dynamic gadolinium-enhanced subtraction MRI is a simple and promising means of early recognition of ischemia in LCP. (orig.)

  2. Tc99m-Tetrofosmin and Thallium-201 SPECT imaging of pituitary tumors: Preliminary results

    International Nuclear Information System (INIS)

    Yarman, S.; Mudun, A.

    2002-01-01

    Aim: It has been reported that pituitary adenomas accumulate Thallium -201(Tl-201), Tc99m-sestamibi and In111-Octreotide. These agents maybe useful in the diagnosis and follow-up of pituitary adenomas. Tc99m-tetrofosmin also has been shown as an tumor seeking agent in various tumors. The aim of this study is to evaluate the accumulation of Tc99m-tetrofosmin in pituitary adenomas and compare the results to Tl-201 SPECT. Methods: We performed Tc99m-Tetrofosmin and Tl-201 SPECT imaging on 5 patients (pts) with pituitary tumors, 3 patients with acromegaly, 1 patient with macro prolactinoma, and 1 patient with nonfunctional tumor (1 female, 4 male, age range: 26-50). SPECT imaging of cranium were obtained 20 min after intravenous injection of 111 MBq Tl-201 and 555 MBq Tc99m-Tetrofosmin on different days with a dual head gamma camera. All but one patient had surgical therapy. One patient had medical treatment. One patient had post surgical imaging with both Tetrofosmin and Tl-201 and 2 pts had only with Thallium. Semiquantitative analysis were performed by calculating tumor to background ratio from the mean counts of the created ROI's. Results: All adenomas showed prominent uptake with both Thallium and Tetrofosmin. The mean tumor to background ratios were 2.3 (range: 1.2-4.29) with Thallium and 3.57 (range: 1.6-6.86) with Tetrofosmin. Post therapy images showed no significant uptake in pituitary region with both agents in 2 patients. Post therapy mean Thallium uptake ratio in 3 pts was 1.64. One patient with acromegaly showed no decrease in thallium uptake, but showed some decrease in tetrofosmin uptake. Conclusion: Although our patient number is limited, these preliminary results indicate that Tc99m-tetrofosmin has also strong affinity for pituitary adenomas as does Thallium, either the adenoma is functioning or non-functioning. It may have a potential value to evaluate the response to therapy

  3. Strain measurement of objects subjected to aerodynamic heating using digital image correlation: experimental design and preliminary results.

    Science.gov (United States)

    Pan, Bing; Jiang, Tianyun; Wu, Dafang

    2014-11-01

    In thermomechanical testing of hypersonic materials and structures, direct observation and quantitative strain measurement of the front surface of a test specimen directly exposed to severe aerodynamic heating has been considered as a very challenging task. In this work, a novel quartz infrared heating device with an observation window is designed to reproduce the transient thermal environment experienced by hypersonic vehicles. The specially designed experimental system allows the capture of test article's surface images at various temperatures using an optical system outfitted with a bandpass filter. The captured images are post-processed by digital image correlation to extract full-field thermal deformation. To verify the viability and accuracy of the established system, thermal strains of a chromiumnickel austenite stainless steel sample heated from room temperature up to 600 °C were determined. The preliminary results indicate that the air disturbance between the camera and the specimen due to heat haze induces apparent distortions in the recorded images and large errors in the measured strains, but the average values of the measured strains are accurate enough. Limitations and further improvements of the proposed technique are discussed.

  4. Measurement of pressure ridges in SAR images of sea ice - Preliminary results on scattering theory

    Science.gov (United States)

    Vesecky, J. F.; Smith, M. P.; Daida, J. M.; Samadani, R.; Camiso, J. C.

    1992-01-01

    Sea ice ridges and keels (hummocks and bummocks) are important in sea ice research for both scientific and practical reasons. A long-term objective is to make quantitative measurements of sea ice ridges using synthetic aperture radar (SAR) images. The preliminary results of a scattering model for sea ice ridge are reported. The approach is through the ridge height variance spectrum Psi(K), where K is the spatial wavenumber, and the two-scale scattering model. The height spectrum model is constructed to mimic height statistics observed with an airborne optical laser. The spectrum model is used to drive a two-scale scattering model. Model results for ridges observed at C- and X-band yield normalized radar cross sections that are 10 to 15 dB larger than the observed cross sections of multiyear ice over the range of angles of incidence from 10 to 70 deg.

  5. Preliminary clinical results: an analyzing tool for 2D optical imaging in detection of active inflammation in rheumatoid arthritis

    Science.gov (United States)

    Adi Aizudin Bin Radin Nasirudin, Radin; Meier, Reinhard; Ahari, Carmen; Sievert, Matti; Fiebich, Martin; Rummeny, Ernst J.; No"l, Peter B.

    2011-03-01

    Optical imaging (OI) is a relatively new method in detecting active inflammation of hand joints of patients suffering from rheumatoid arthritis (RA). With the high number of people affected by this disease especially in western countries, the availability of OI as an early diagnostic imaging method is clinically highly relevant. In this paper, we present a newly in-house developed OI analyzing tool and a clinical evaluation study. Our analyzing tool extends the capability of existing OI tools. We include many features in the tool, such as region-based image analysis, hyper perfusion curve analysis, and multi-modality image fusion to aid clinicians in localizing and determining the intensity of inflammation in joints. Additionally, image data management options, such as the full integration of PACS/RIS, are included. In our clinical study we demonstrate how OI facilitates the detection of active inflammation in rheumatoid arthritis. The preliminary clinical results indicate a sensitivity of 43.5%, a specificity of 80.3%, an accuracy of 65.7%, a positive predictive value of 76.6%, and a negative predictive value of 64.9% in relation to clinical results from MRI. The accuracy of inflammation detection serves as evidence to the potential of OI as a useful imaging modality for early detection of active inflammation in patients with rheumatoid arthritis. With our in-house developed tool we extend the usefulness of OI imaging in the clinical arena. Overall, we show that OI is a fast, inexpensive, non-invasive and nonionizing yet highly sensitive and accurate imaging modality.-

  6. Functional magnetic resonance imaging in disorders of consciousness: preliminary results of an innovative analysis of brain connectivity.

    Science.gov (United States)

    De Pasquale, Francesco; Caravasso, Chiara Falletta; Péran, Patrice; Catani, Sheila; Tuovinen, Noora; Sabatini, Umberto; Formisano, Rita

    2015-01-01

    The aim of this preliminary study was to present a new approach for connectivity analysis in patients with severe acquired brain injury (ABI) that overcomes some of the difficulties created by anatomical abnormalities due to the brain injury. Using a data-driven approach, resting-state structural MRI (sMRI) and functional MRI (fMRI) data from three severe ABI patients - two with disorders of consciousness (DOC) and one who had recovered consciousness (non-DOC) - were integrated and analyzed. Parameters extracted from the distribution of the connectivity values, such as mean, standard deviation and skeweness, were considered. The distribution parameters estimated seem to provide an accurate multivariate classification of the considered cases that can be summarized as follows: connectivity in the severe ABI patients with DOC was on average lower than in the severe ABI non-DOC patient and healthy subjects. The dispersion of connectivity values of the severe ABI patients, non-DOC and DOC, was comparable, however the shape of the distribution was different in the non-DOC patient. Eventually, seed-based connectivity maps of the default mode Functional magnetic resonance imaging in disorders of consciousness: preliminary results of an innovative analysis of brain connectivity network show a pattern of increasing disruption of this network from the healthy subjects to non-DOC and DOC patients. Consistent results are obtained using an ICA-based approach..

  7. Imaging-Guided Percutaneous Radiofrequency Ablation of Adrenal Metastases: Preliminary Results at a Single Institution with a Single Device

    International Nuclear Information System (INIS)

    Carrafiello, G.; Lagana, D.; Recaldini, C.; Giorgianni, A.; Ianniello, A.; Lumia, D.; D'Ambrosio, A.; Petulla, M.; Dionigi, G.; Fugazzola, C.

    2008-01-01

    The aim of this study was to show the feasibility, safety, imaging appearance, and short-term efficacy of image-guided percutaneous radiofrequency ablation (RFA) of adrenal metastases (AM). Seven imaging-guided percutaneous RFA treatments were performed in six patients (two men and four women; mean age, 67.2 years; range, 55-74 years) with six AM who were referred to our institution from 2003 to 2006. One patient was treated twice for recurrence after first treatment. The average diameter of the treated AM was 29 mm (range, 15-40 mm). In all patients, the diagnosis was obtained with CT current protocols in use at our institution and confirmed by pathology with an image-guided biopsy. No major complications occurred. In one patient shortly after initiation of the procedure, severe hypertension was noted; another patient developed post-RFA syndrome. In five of six lesions, there was no residual enhancement of the treated tumor. In one patient CT examination showed areas of residual enhancement of the tumor after treatment. Our preliminary results suggest that imaging-guided percutaneous RFA is effective for local control of AM, without major complications and with a low morbidity rate related to the procedure. Long-term follow-up will need to be performed and appropriate patient selection criteria will need to be determined in future randomized trials.

  8. Hybrid Spectral Micro-CT: System Design, Implementation, and Preliminary Results

    CERN Document Server

    Bennett, James R; Xu, Qiong; Yu, Hengyong; Walsh, Michael; Butler, Anthony; Butler, Phillip; Cao, Guohua; Mohs, Aaron; Wang, Ge

    2014-01-01

    Spectral CT has proven an important development in biomedical imaging, and there have been several publications in the past years demonstrating its merits in pre-clinical and clinical applications. In 2012, Xu et al. reported that near-term implementation of spectral micro-CT could be enhanced by a hybrid architecture: a narrow-beam spectral "interior" imaging chain integrated with a traditional wide-beam "global" imaging chain. This hybrid integration coupled with compressive sensing (CS)-based interior tomography demonstrated promising results for improved contrast resolution, and decreased system cost and radiation dose. The motivation for the current study is implementation and evaluation of the hybrid architecture with a first-of-its-kind hybrid spectral micro-CT system. Preliminary results confirm improvements in both contrast and spatial resolution. This technology is shown to merit further investigation and potential application in future spectral CT scanner design.

  9. MR imaging of prostate. Preliminary experience with calculated imaging in 28 cases

    International Nuclear Information System (INIS)

    Gevenois, P.A.; Van Regemorter, G.; Ghysels, M.; Delepaut, A.; Van Gansbeke, D.; Struyven, J.

    1988-01-01

    The majority of studies with MR imaging in prostate disease are based on a semiology obtained using images weighted in T1 and T2. A study was carried out to evaluate effects of images calculated in T1 and T2 obtained at 0.5T. This preliminary study concerns 28 prostate examinations with spin-echo acquisition and inversion-recuperation parameters, and provided images calculated in T1, weighted and calculated in T2. Images allowed detection and characterization of prostate lesions. However, although calculated images accentuate discrimination of the method, the weighted images conserve their place because of their improved spatial resolution [fr

  10. PRELIMINARY RESULTS OF THE COMPARISON OF SATELLITE IMAGERS USING TUZ GÖLÜ AS A REFERENCE STANDARD

    Directory of Open Access Journals (Sweden)

    H. Özen

    2012-07-01

    Full Text Available Earth surfaces, such as deserts, salt lakes, and playas, have been widely used in the vicarious radiometric calibration of optical earth observation satellites. In 2009, the Infrared and Visible Optical Sensors (IVOS sub-group of the Committee of Earth Observation Satellites (CEOS Working Group on Calibration and Validation (WGCV designated eight LANDNET reference sites to focus international efforts, facilitate traceability and enable the establishment of measurement "best practices." With support from the European Space Agency (ESA, one of the LANDNET sites, the Tuz Gölü salt lake located in central Turkey, was selected to host a cross-comparison of measurement instrumentation and methodologies conducted by 11 different ground teams across the globe. This paper provides an overview of the preliminary results of the cross-comparison of the ground-based spectral measurements made during the CEOS Land Comparison 13-27 August, 2010 with the simultaneous satellite image data acquisitions of the same site.

  11. Breast imaging with the SoftVue imaging system: first results

    Science.gov (United States)

    Duric, Neb; Littrup, Peter; Schmidt, Steven; Li, Cuiping; Roy, Olivier; Bey-Knight, Lisa; Janer, Roman; Kunz, Dave; Chen, Xiaoyang; Goll, Jeffrey; Wallen, Andrea; Zafar, Fouzaan; Allada, Veerendra; West, Erik; Jovanovic, Ivana; Li, Kuo; Greenway, William

    2013-03-01

    For women with dense breast tissue, who are at much higher risk for developing breast cancer, the performance of mammography is at its worst. Consequently, many early cancers go undetected when they are the most treatable. Improved cancer detection for women with dense breasts would decrease the proportion of breast cancers diagnosed at later stages, which would significantly lower the mortality rate. The emergence of whole breast ultrasound provides good performance for women with dense breast tissue, and may eliminate the current trade-off between the cost effectiveness of mammography and the imaging performance of more expensive systems such as magnetic resonance imaging. We report on the performance of SoftVue, a whole breast ultrasound imaging system, based on the principles of ultrasound tomography. SoftVue was developed by Delphinus Medical Technologies and builds on an early prototype developed at the Karmanos Cancer Institute. We present results from preliminary testing of the SoftVue system, performed both in the lab and in the clinic. These tests aimed to validate the expected improvements in image performance. Initial qualitative analyses showed major improvements in image quality, thereby validating the new imaging system design. Specifically, SoftVue's imaging performance was consistent across all breast density categories and had much better resolution and contrast. The implications of these results for clinical breast imaging are discussed and future work is described.

  12. Correlation of early-phase 18F-florbetapir (AV-45/Amyvid) PET images to FDG images: preliminary studies

    International Nuclear Information System (INIS)

    Hsiao, Ing-Tsung; Hsieh, Chia-Ju; Wey, Shiaw-Pyng; Lin, Kun-Ju; Huang, Chin-Chang; Hsu, Wen-Chun; Yen, Tzu-Chen; Kung, Mei-Ping

    2012-01-01

    18 F-Florbetapir (AV-45/Amyvid) is a novel positron emission tomography (PET) tracer for imaging plaque pathology in Alzheimer's disease (AD), while PET images of fluorodeoxyglucose (FDG) for cerebral glucose metabolism can provide complementary information to amyloid plaque images for diagnosis of AD. The goal of this preliminary study was to investigate the perfusion-like property of relative cerebral blood flow estimates (R 1 ) and summed early-phase AV-45 images [perfusion AV-45 (pAV-45)] and optimize the early time frame for pAV-45. Dynamic AV-45 PET scans (0-180 min) were performed in seven subjects. pAV-45, late-phase AV-45, and FDG images were spatially normalized to the Montreal Neurological Institute template aided by individual MRI images, and the corresponding standardized uptake value ratio (SUVR) was computed. The R 1 images were derived from a simplified reference tissue model. Correlations between regional and voxelwise R 1 and the corresponding FDG images were calculated. An optimization of time frames of pAV-45 was conducted in terms of correlation to FDG images. The optimal early time frame was validated in a separate cohort. The regional distribution in the R 1 images correlated well (R = 0.91) to that of the FDG within subjects. Consistently high correlation was noted across a long range of time frames. The maximal correlation of pAV-45 to FDG SUVR of R = 0.95 was observed at the time frame of 1-6 min, while the peak correlation of R = 0.99 happened at 0-2 min between pAV-45 and R 1 . A similar result was achieved in the validation cohort. Preliminary results showed that the distribution patterns of R 1 and pAV-45 images are highly correlated with normalized FDG images, and the initial 5-min early time frame of 1-6 min is potentially useful in providing complementary FDG-like information to the amyloid plaque density by late-phase AV-45 images. (orig.)

  13. Preliminary experiment of fast neutron imaging with direct-film method

    International Nuclear Information System (INIS)

    Pei Yuyang; Tang Guoyou; Guo Zhiyu; Zhang Guohui

    2005-01-01

    A preliminary experiment is conducted with direct-film method under the condition that fast neutron is generated by the reaction of 9 Be(d, n) on the Beijing University 4.5 MV Van de Graaff, whose energy is lower than 7 MeV. Basic characteristics of direct-film neutron radiography system are investigated with the help of samples in different materials, different thickness and holes of different diameter. The fast neutron converter, which is vital for fast neutron imaging, is produced with the materials made in China. The result indicates that fast neutron converter can meet the requirement of fast neutron imaging; further research of fast neutron imaging can be conducted on the accelerator and neutron-generator in China. (authors)

  14. Diagnostic value of a new myocardial perfusion agent, teboroxime (SO 30,217), utilizing a rapid planar imaging protocol: Preliminary results

    International Nuclear Information System (INIS)

    Hendel, R.C.; McSherry, B.; Karimeddini, M.; Leppo, J.A.

    1990-01-01

    Technetium-99m-labeled agents have advantages over thallium-201 in terms of photon statistics, cost and clinical availability. They have been suggested as an alternative to thallium for myocardial perfusion imaging. Teboroxime is a new boronic acid adduct of technetium dioxime (BATO) compound that demonstrates favorable characteristics in preliminary studies. With use of a novel (seated) patient positioning technique and a rapid dynamic acquisition protocol, 30 patients underwent planar imaging with teboroxoime while at rest and after maximal treadmill exercise. Postexercise scans were completed in an average time (mean +/- SD) of 4.4 +/- 1.6 min, with 4.8 +/- 1.5 min for the views at rest. These results were compared with coronary arteriography or thallium scintigraphy after treadmill exercise, or both. Diagnostic agreement (abnormal versus normal) was present in 28 of the 30 patients (p less than 0.001). Regarding physiologic assessment as compared with thallium scintigraphy, the finding of infarction and ischemia was concordant in 89% and 86% of patients, respectively. This report describes the initial use of teboroxime with a rapid dynamic planar imaging technique, resulting in a high correlation with exercise thallium scintigraphy. Delayed postexercise images obtained 5 to 10 min after exercise demonstrated rapid disappearance of exercise-induced defects noted on the initial (0 to 5 min) postexercise views. The rapid differential washout with teboroxime has not been previously described and the possible clinical significance is discussed

  15. Combined optical and single photon emission imaging: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Boschi, Federico; Calderan, Laura; Sbarbati, Andrea [Department of Morphological-Biomedical Sciences, Section of Anatomy and Histology, University of Verona, Verona (Italy); Spinelli, Antonello E [Medical Physics Department, San Raffaele Scientific Institute, Milan (Italy); D' Ambrosio, Daniela; Marengo, Mario [Medical Physics Department, S. Orsola Malpighi Hospital, Bologna (Italy)], E-mail: federico.boschi@univr.it

    2009-12-07

    In vivo optical imaging instruments are generally devoted to the acquisition of light coming from fluorescence or bioluminescence processes. Recently, an instrument was conceived with radioisotopic detection capabilities (Kodak in Vivo Multispectral System F) based on the conversion of x-rays from the phosphorus screen. The goal of this work is to demonstrate that an optical imager (IVIS 200, Xenogen Corp., Alameda, USA), designed for in vivo acquisitions of small animals in bioluminescent and fluorescent modalities, can even be employed to detect signals due to radioactive tracers. Our system is based on scintillator crystals for the conversion of high-energy rays and a collimator. No hardware modifications are required. Crystals alone permit the acquisition of photons coming from an in vivo 20 g nude mouse injected with a solution of methyl diphosphonate technetium 99 metastable (Tc99m-MDP). With scintillator crystals and collimators, a set of measurements aimed to fully characterize the system resolution was carried out. More precisely, system point spread function and modulation transfer function were measured at different source depths. Results show that system resolution is always better than 1.3 mm when the source depth is less than 10 mm. The resolution of the images obtained with radioactive tracers is comparable with the resolution achievable with dedicated techniques. Moreover, it is possible to detect both optical and nuclear tracers or bi-modal tracers with only one instrument. (letter to the editor)

  16. Correlation of early-phase {sup 18}F-florbetapir (AV-45/Amyvid) PET images to FDG images: preliminary studies

    Energy Technology Data Exchange (ETDEWEB)

    Hsiao, Ing-Tsung; Hsieh, Chia-Ju; Wey, Shiaw-Pyng; Lin, Kun-Ju [Chang Gung Memorial Hospital, Department of Nuclear Medicine and Molecular Imaging Center, Taipei (China); Chang Gung University, Healthy Aging Research Center and Department of Medical Imaging and Radiological Sciences, Taipei (China); Huang, Chin-Chang; Hsu, Wen-Chun [Chang Gung Memorial Hospital, Department of Neurology, Taipei (China); Yen, Tzu-Chen [Chang Gung Memorial Hospital, Department of Nuclear Medicine and Molecular Imaging Center, Taipei (China); Kung, Mei-Ping [Chang Gung Memorial Hospital, Department of Nuclear Medicine and Molecular Imaging Center, Taipei (China); Chang Gung University, Healthy Aging Research Center and Department of Medical Imaging and Radiological Sciences, Taipei (China); University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States)

    2012-04-15

    {sup 18}F-Florbetapir (AV-45/Amyvid) is a novel positron emission tomography (PET) tracer for imaging plaque pathology in Alzheimer's disease (AD), while PET images of fluorodeoxyglucose (FDG) for cerebral glucose metabolism can provide complementary information to amyloid plaque images for diagnosis of AD. The goal of this preliminary study was to investigate the perfusion-like property of relative cerebral blood flow estimates (R{sub 1}) and summed early-phase AV-45 images [perfusion AV-45 (pAV-45)] and optimize the early time frame for pAV-45. Dynamic AV-45 PET scans (0-180 min) were performed in seven subjects. pAV-45, late-phase AV-45, and FDG images were spatially normalized to the Montreal Neurological Institute template aided by individual MRI images, and the corresponding standardized uptake value ratio (SUVR) was computed. The R{sub 1} images were derived from a simplified reference tissue model. Correlations between regional and voxelwise R{sub 1} and the corresponding FDG images were calculated. An optimization of time frames of pAV-45 was conducted in terms of correlation to FDG images. The optimal early time frame was validated in a separate cohort. The regional distribution in the R{sub 1} images correlated well (R = 0.91) to that of the FDG within subjects. Consistently high correlation was noted across a long range of time frames. The maximal correlation of pAV-45 to FDG SUVR of R = 0.95 was observed at the time frame of 1-6 min, while the peak correlation of R = 0.99 happened at 0-2 min between pAV-45 and R{sub 1}. A similar result was achieved in the validation cohort. Preliminary results showed that the distribution patterns of R{sub 1} and pAV-45 images are highly correlated with normalized FDG images, and the initial 5-min early time frame of 1-6 min is potentially useful in providing complementary FDG-like information to the amyloid plaque density by late-phase AV-45 images. (orig.)

  17. Preliminary results from a crowdsourcing experiment in immunohistochemistry.

    Science.gov (United States)

    Della Mea, Vincenzo; Maddalena, Eddy; Mizzaro, Stefano; Machin, Piernicola; Beltrami, Carlo A

    2014-01-01

    Crowdsourcing, i.e., the outsourcing of tasks typically performed by a few experts to a large crowd as an open call, has been shown to be reasonably effective in many cases, like Wikipedia, the Chess match of Kasparov against the world in 1999, and several others. The aim of the present paper is to describe the setup of an experimentation of crowdsourcing techniques applied to the quantification of immunohistochemistry. Fourteen Images from MIB1-stained breast specimens were first manually counted by a pathologist, then submitted to a crowdsourcing platform through a specifically developed application. 10 positivity evaluations for each image have been collected and summarized using their median. The positivity values have been then compared to the gold standard provided by the pathologist by means of Spearman correlation. Contributors were in total 28, and evaluated 4.64 images each on average. Spearman correlation between gold and crowdsourced positivity percentages is 0.946 (p crowdsourcing for an image analysis task that is currently time-consuming when done by human experts. Crowdsourced work can be used in various ways, in particular statistically agregating data to reduce identification errors. However, in this preliminary experimentation we just considered the most basic indicator, that is the median positivity percentage, which provided overall good results. This method might be more aimed to research than routine: when a large number of images are in need of ad-hoc evaluation, crowdsourcing may represent a quick answer to the need.

  18. Preliminary results of a program of quality assurance applied to the image service of a public hospital

    International Nuclear Information System (INIS)

    Almeida, Claudio Domingues de; Ferreira, Rubemar de Souza; Marechal, Maria Helena H.; Milano, Nelly Ester

    2001-01-01

    Overall quality in radiological protection and medical image depend largely on keeping certain safety standards and technical procedures in good levels. In this way, in June 1998, the Ministry of Health published the document 453 - Guidelines of Radiological Protection to Medical and Dental Practices, defining different levels of actions and responsibility for radiological installation where the critical starting point was the necessity of a previous quality assurance program (QAP) into the radiological service. Preliminary results of a QAP realized in the Department of Radiology of a high complexity Hospital in Rio de Janeiro has showed that, although the importance of 453 Regulation be recognized, there is a few motivation for implementing it. Besides, during 1999 it was possible to identify film losses of 14,9 % related only to the repetition of exposures in the patients, reflecting in terms of cost about U$ 100,000 a year. Results suggest that losses of 64% of total film are due to under or over exposures and 15% are due to inadequate positioning of either film or patient, evidencing the need for training the technical and medical staff . (author)

  19. Cell emulation and preliminary results.

    Science.gov (United States)

    2016-07-01

    This report details preliminary results of the testing plan implemented by the Hawaii Natural Energy Institute to evaluate Electric Vehicle (EV) battery durability and reliability under electric utility grid operations. Commercial EV battery cells ar...

  20. Antares: preliminary demonstrator results

    International Nuclear Information System (INIS)

    Kouchner, A.

    2000-05-01

    The ANTARES collaboration is building an undersea neutrino telescope off Toulon (Mediterranean sea) with effective area ∼ 0.1 km 2 . An extensive study of the site properties has been achieved together with software analysis in order to optimize the performance of the detector. Results are summarized here. An instrumented line, linked to shore for first time via an electro-optical cable, has been immersed late 1999. The preliminary results of this demonstrator line are reported. (author)

  1. A Morphing Technique Applied to Lung Motions in Radiotherapy: Preliminary Results

    Directory of Open Access Journals (Sweden)

    R. Laurent

    2010-01-01

    Full Text Available Organ motion leads to dosimetric uncertainties during a patient’s treatment. Much work has been done to quantify the dosimetric effects of lung movement during radiation treatment. There is a particular need for a good description and prediction of organ motion. To describe lung motion more precisely, we have examined the possibility of using a computer technique: a morphing algorithm. Morphing is an iterative method which consists of blending one image into another image. To evaluate the use of morphing, Four Dimensions Computed Tomography (4DCT acquisition of a patient was performed. The lungs were automatically segmented for different phases, and morphing was performed using the end-inspiration and the end-expiration phase scans only. Intermediate morphing files were compared with 4DCT intermediate images. The results showed good agreement between morphing images and 4DCT images: fewer than 2 % of the 512 by 256 voxels were wrongly classified as belonging/not belonging to a lung section. This paper presents preliminary results, and our morphing algorithm needs improvement. We can infer that morphing offers considerable advantages in terms of radiation protection of the patient during the diagnosis phase, handling of artifacts, definition of organ contours and description of organ motion.

  2. Experimental MR imaging with Gd-DOTA: Preliminary results

    International Nuclear Information System (INIS)

    Schouman-Claeys, E.; Kien, P.; Caille, J.M.; Bonnemain, B.; Frija, G.

    1986-01-01

    To evaluate the paramagnetic properties of a new gadolinium chelate, Gd-DOTA, in vitro and in vivo MR imaging was performed with a 0.5-T supraconductive magnet. The in vitro study consisted in measuring the MR signal obtained with various concentrations of Gd-DOTA and Gd-DTPA in different solutions. Potentialization of the paramagnetic properties of both DOTA and DTPA can be achieved by deuterium, glycerol, and protein solutions. The in vivo study was performed in rabbits with various experimental lesions. Enhancement of anatomic details was obtained with both Gd-DOTA and Gd-DTPA. There was no significant difference between Gd-DOTA and Gd-DTPA, both for in vitro and in vivo experiments. Gd-DOTA appears to be a potential paramagnetic agent for MR imaging

  3. Radiolabeled antifibrin antibody in the detection of venous thrombosis: Preliminary results

    International Nuclear Information System (INIS)

    Alavi, A.; Palevsky, H.I.; Gupta, N.; Meranze, S.; Kelley, M.A.; Jatlow, A.D.; Schaible, T.F.; Brown, J.; Berger, H.J.

    1990-01-01

    The recent development of monoclonal antibodies against components of coagulated blood may provide new approaches to the diagnosis of venous thrombosis. Scanning with an indium-111-labeled Fab fragment of a murine monoclonal antifibrin antibody (59D8) and ascending contrast venography were performed in 33 patients. Images of the calves, popliteal fossae, thighs, and pelvis were obtained immediately, 4-6 hours, and 24 hours after injection of 2 mCi (74 MBq) of the antibody. All images were read in a blinded manner. Findings in both studies were positive in 28 patients and negative in three. In 19 patients not undergoing heparin therapy, 19 specific anatomic sites were positive on venograms and 29 were positive on antibody images (19 sites matched). In 14 patients undergoing heparin therapy, 34 sites were positive on venograms and 27 were positive on antibody images (22 sites matched). In most patients, positive results were noted within 1 hour of antibody injection. No adverse effects were noted with the antibody preparation. Preliminary data suggest that antifibrin antibody imaging is sensitive in detecting clots, is safe to use, and may have a role in diagnosing and managing venous thrombosis

  4. Tissue characterization using magnetic resonance elastography: preliminary results

    International Nuclear Information System (INIS)

    Kruse, S.A.; Smith, J.A.; Lawrence, A.J.; Dresner, M.A.; Manduca, A.; Greenleaf, J.F.; Ehman, R.L.

    2000-01-01

    The well-documented effectiveness of palpation as a diagnostic technique for detecting cancer and other diseases has provided motivation for developing imaging techniques for non-invasively evaluating the mechanical properties of tissue. A recently described approach for elasticity imaging, using propagating acoustic shear waves and phase-contrast MRI, has been called magnetic resonance elastography (MRE). The purpose of this work was to conduct preliminary studies to define methods for using MRE as a tool for addressing the paucity of quantitative tissue mechanical property data in the literature. Fresh animal liver and kidney tissue specimens were evaluated with MRE at multiple shear wave frequencies. The influence of specimen temperature and orientation on measurements of stiffness was studied in skeletal muscle. The results demonstrated that all of the materials tested (liver, kidney, muscle and tissue-simulating gel) exhibit systematic dependence of shear stiffness on shear rate. These data are consistent with a viscoelastic model of tissue mechanical properties, allowing calculation of two independent tissue properties from multiple-frequency MRE data: shear modulus and shear viscosity. The shear stiffness of tissue can be substantially affected by specimen temperature. The results also demonstrated evidence of shear anisotropy in skeletal muscle but not liver tissue. The measured shear stiffness in skeletal muscle was found to depend on both the direction of propagation and polarization of the shear waves. (author)

  5. Preliminary results of steel containment vessel model test

    International Nuclear Information System (INIS)

    Matsumoto, T.; Komine, K.; Arai, S.

    1997-01-01

    A high pressure test of a mixed-scaled model (1:10 in geometry and 1:4 in shell thickness) of a steel containment vessel (SCV), representing an improved boiling water reactor (BWR) Mark II containment, was conducted on December 11-12, 1996 at Sandia National Laboratories. This paper describes the preliminary results of the high pressure test. In addition, the preliminary post-test measurement data and the preliminary comparison of test data with pretest analysis predictions are also presented

  6. Fast Blood Vector Velocity Imaging: Simulations and Preliminary In Vivo Results

    DEFF Research Database (Denmark)

    Udesen, Jesper; Gran, Fredrik; Hansen, Kristoffer Lindskov

    2007-01-01

    for each pulse emission. 2) The transmitted pulse consists of a 13 bit Barker code which is transmitted simultaneously from each transducer element. 3) The 2-D vector velocity of the blood is found using 2-D speckle tracking between segments in consecutive speckle images. III Results: The method was tested...

  7. Preliminary results of a new workflow for MRI/CT-based image-guided brachytherapy in cervical carcinoma.

    Science.gov (United States)

    Nemoto, Miho Watanabe; Iwai, Yuma; Togasaki, Gentaro; Kurokawa, Marie; Harada, Rintarou; Kobayashi, Hiroki; Uno, Takashi

    2017-12-01

    We propose a method of image-guided brachytherapy (IGBT) that combines MRI-based target volume delineation for the first fraction with CT datasets of subsequent fractions, using an automatic, applicator-based co-registration, and report our preliminary experience. The MRI of the first fraction was used for the first brachytherapy planning. For each subsequent brachytherapy fraction, after the same applicator insertion, a new CT scan with the applicator in place was obtained. The MR image set was registered to the subsequent brachytherapy treatment planning CT using the applicator for rigid body registration. To demonstrate the registration quality, we used here the Dice index as a measurement of tandem delineation overlap between CT and MRI. The median Dice index was 0.879 (range 0.610-0.932), which indicated that the contours on CT and MRI fitted well. With this combination method, the median D90 of HR CTV and the calculated D2 cm 3 of the bladder, rectum, and sigmoid in each fraction were 7.2 (4.0-10.4), 5.9 (2.3-7.7), 4.0 (1.9-6.7), and 3.8 (0.6-7.2) Gy, respectively. Our described method of MRI-guided IGBT offers a practical option for the benefits of target delineation.

  8. First high speed imaging of lightning from summer thunderstorms over India: Preliminary results based on amateur recording using a digital camera

    Science.gov (United States)

    Narayanan, V. L.

    2017-12-01

    For the first time, high speed imaging of lightning from few isolated tropical thunderstorms are observed from India. The recordings are made from Tirupati (13.6oN, 79.4oE, 180 m above mean sea level) during summer months with a digital camera capable of recording high speed videos up to 480 fps. At 480 fps, each individual video file is recorded for 30 s resulting in 14400 deinterlaced images per video file. An automatic processing algorithm is developed for quick identification and analysis of the lightning events which will be discussed in detail. Preliminary results indicating different types of phenomena associated with lightning like stepped leader, dart leader, luminous channels corresponding to continuing current and M components are discussed. While most of the examples show cloud to ground discharges, few interesting cases of intra-cloud, inter-cloud and cloud-air discharges will also be displayed. This indicates that though high speed cameras with few 1000 fps are preferred for a detailed study on lightning, moderate range CMOS sensor based digital cameras can provide important information as well. The lightning imaging activity presented herein is initiated as an amateur effort and currently plans are underway to propose a suite of supporting instruments to conduct coordinated campaigns. The images discussed here are acquired from normal residential area and indicate how frequent lightning strikes are in such tropical locations during thunderstorms, though no towering structures are nearby. It is expected that popularizing of such recordings made with affordable digital cameras will trigger more interest in lightning research and provide a possible data source from amateur observers paving the way for citizen science.

  9. Coherent scattering X-ray imaging at the Brazilian National Synchrotron Laboratory: Preliminary breast images

    Energy Technology Data Exchange (ETDEWEB)

    Castro, C.R.F. [Nuclear Instrumentation Laboratory-COPPE/UFRJ, P.O. Box 68509, Rio de Janeiro 21945-970 (Brazil); Barroso, R.C. [Physics Institute-University of Rio de Janeiro State, Rio de Janeiro 20559-900 (Brazil)]. E-mail: cely@uerij.br; Oliveira, L.F. de [Physics Institute-University of Rio de Janeiro State, Rio de Janeiro 20559-900 (Brazil); Lopes, R.T. [Nuclear Instrumentation Laboratory-COPPE/UFRJ, P.O. Box 68509, Rio de Janeiro 21945-970 (Brazil)

    2005-08-11

    The angular distribution of coherent scatter (low-momentum transfer) carries information about atomic structures, resulting in a pattern, which can be used to reconstruct a series of images. Coherent-scatter computed tomography is a novel imaging method developed to produce cross-sectional images based on the X-ray diffraction properties of an object. A different approach to coherent X-ray imaging is possible by fixing the detector at a given scatter angle {theta}, which produces an interference peak and then, carried out a tomography in the standard way. The cross-sectional images obtained allow determining the spatial dependence of coherent scatter cross-section of selected volume elements of inhomogeneous, extend objects for a single predetermined value of {theta} of interest, leading to a simplification of the data processing and the complexity of the apparatus. This work presents preliminary coherent scattering images carried out at the X-ray Diffraction beamline of the National Synchrotron Light Laboratory in Campinas, Brazil. The specimens were excised human breast tissues fixed in formaline. No frozen procedure was used in order to minimize preferred orientation during sample preparation. About 1mm thick slices cut from each of the fresh samples were mounted in frames without windows and placed on a translator to allow acquisition of scattering spectra. Cylinders containing healthy and cancerous (infiltrating ductal carcinoma) breast tissues were imagined at the characteristic angle for adipose tissue. Transmission and coherent scatter images are compared.

  10. Majolica imaging with THz waves: preliminary results

    Science.gov (United States)

    Catapano, Ilaria; Affinito, Antonio; Guerriero, Luigi; Bisceglia, Bruno; Soldovieri, Francesco

    2016-05-01

    Recent advancements performed in the development of stable and flexible devices working at TeraHertz (THz) frequencies have opened the way at considering this technology as a very interesting noninvasive diagnostic tool in cultural heritage. In this frame, the paper aims at assessing the ability of THz imaging to gather information about preservation state and constructive modalities of majolica artworks. In particular, THz surveys have been carried out on two majolica tiles dated back to the nineteenth century and realized as building cladding at Naples (Italy). The analysis has been performed by means of the Zomega fiber-coupled THz time-domain system. This analysis corroborates the ability of THz to reconstruct irregularities of majolica tile topography, to characterize pigment and glaze losses, and to detect and localize glaze and pigment layer as well as the glaze-clay body interface.

  11. [Accelerated partial breast irradiation with image-guided intensity-modulated radiotherapy following breast-conserving surgery - preliminary results of a phase II clinical study].

    Science.gov (United States)

    Mészáros, Norbert; Major, Tibor; Stelczer, Gábor; Zaka, Zoltán; Mózsa, Emõke; Fodor, János; Polgár, Csaba

    2015-06-01

    The purpose of the study was to implement accelerated partial breast irradiation (APBI) by means of image-guided intensity-modulated radiotherapy (IG-IMRT) following breast-conserving surgery (BCS) for low-risk early invasive breast cancer. Between July 2011 and March 2014, 60 patients with low-risk early invasive (St I-II) breast cancer who underwent BCS were enrolled in our phase II prospective study. Postoperative APBI was given by means of step and shoot IG-IMRT using 4 to 5 fields to a total dose of 36.9 Gy (9×4.1 Gy) using a twice-a-day fractionation. Before each fraction, series of CT images were taken from the region of the target volume using a kV CT on-rail mounted in the treatment room. An image fusion software was used for automatic image registration of the planning and verification CT images. Patient set-up errors were detected in three directions (LAT, LONG, VERT), and inaccuracies were adjusted by automatic movements of the treatment table. Breast cancer related events, acute and late toxicities, and cosmetic results were registered and analysed. At a median follow-up of 24 months (range 12-44) neither locoregional nor distant failure was observed. Grade 1 (G1), G2 erythema, G1 oedema, and G1 and G2 pain occurred in 21 (35%), 2 (3.3%), 23 (38.3%), 6 (10%) and 2 (3.3%) patients, respectively. No G3-4 acute side effects were detected. Among late radiation side effects G1 pigmentation, G1 fibrosis, and G1 fat necrosis occurred in 5 (8.3%), 7 (11.7%), and 2 (3.3%) patients, respectively. No ≥G2 late toxicity was detected. Excellent and good cosmetic outcome was detected in 45 (75%) and 15 (25%) patients. IG-IMRT is a reproducible and feasible technique for the delivery of APBI following conservative surgery for the treatment of low-risk, early-stage invasive breast carcinoma. Preliminary results are promising, early radiation side effects are minimal, and cosmetic results are excellent.

  12. Preliminary results from a high-pressure imaging spectroscopic proportional counter

    International Nuclear Information System (INIS)

    Hall, C.J.; Bazzano, A.; Lewis, R.A.; Parker, B.; Ubertini, P.; Worgan, J.S.

    1992-01-01

    A new type of high-pressure proportional counter, with both spatial resolution and spectroscopic capabilities is being jointly developed by the Istituto di Astrofisica Spaziale (CNR), Frascati, Italy and the SERC Daresbury Laboratory, Warrington, UK. The characteristics of the detector can be optimized for the particular requirement of the experiment, either for x-ray astronomy observations from space, or for the high count rate applications associated with a synchrotron light source. In its baseline configuration, the detector is filled to 5 bar with a xenon/quench gas mixture and will be sensitive over the energy range 5 keV to 150 keV (2.5 to 0.08 A). The positional resolution will range from 500 μm at the lower energies to around 1 mm at the higher end of the energy range. The current prototype has a sensitive area of 200x200 mm. The final version is hoped to have an area closer to 425x425 mm. The very small photon absorption length in the higher pressure gas allows the parallax effect, a feature of 1 atmosphere detectors, to be greatly reduced. The timing resolution (150 ns) of the detector enables both a high-rate capability and the possibility of the escape gate technique to achieve higher spectral resolution at energies > the Xe K edge. Preliminary results are presented showing the spectral and positional resolution for the prototype detector

  13. A hand-held imaging probe for radio-guided surgery: physical performance and preliminary clinical experience

    International Nuclear Information System (INIS)

    Pitre, S.; Menard, L.; Charon, Y.; Solal, M.; Garbay, J.R.

    2003-01-01

    Improvements in the specificity of radiopharmaceutical compounds have been paralleled by an upsurge of interest in developing small detectors to assist surgeons in localizing tumour tissue during surgery. This study reports the main technical features and physical characteristics of a new hand-held gamma camera dedicated to accurate and real-time intra-operative imaging. First clinical experience is also reported. The POCI (Per-operative Compact Imager) camera consists of a head module composed of a high-resolution interchangeable lead collimator and a CsI(Na) crystal plate optically coupled to an intensified position-sensitive diode. The current prototype has a 40-mm diameter field of view, an outer diameter of 9.5 cm, a length of 9 cm and a weight of 1.2 kg. Overall detector imaging characteristics were evaluated by technetium-99m phantom measurements. Three patients with breast cancer previously scheduled to undergo sentinel lymph node detection were selected for the preliminary clinical experience. Preoperative images of the lymphatic basin obtained using the POCI camera were compared with conventional transcutaneous explorations using a non-imaging gamma probe. The full-width at half-maximum (FWHM) spatial resolution was investigated in both air and scattering medium; when the phantom was placed in contact with the collimator, the POCI camera exhibited a 3.2 mm FWHM. The corresponding sensitivity was 290 cps/MBq. The preliminary clinical results showed that POCI was able to predict the number and location of all SLNs. In one case, two deep radioactive nodes missed by the gamma probe were detected on the intra-operative images. This very initial experience demonstrates that the physical performance of the POCI camera is adequate for radio-guided surgery. These results are sufficiently encouraging to prompt further evaluation studies designed to determine the specific and optimal clinical role of intra-operative imaging devices

  14. Dynamic pelvic floor MR imaging at 3 T in patients with clinical signs of urinary incontinence-preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Morakkabati-Spitz, Nuschin; Willinek, Winfried A.; Traeber, Frank; Jaeger, Ursula; Schild, Hans H. [University of Bonn, Department of Radiology, Bonn (Germany); Gieseke, Juergen [University of Bonn, Department of Radiology, Bonn (Germany); Philips Medical Systems, Best (Netherlands); Bastian, Patrick J. [University of Munich, Department of Urology, Munich (Germany); Schmitz, Bettina; Mueller, Stefan C. [University of Bonn, Department of Urology, Bonn (Germany)

    2008-11-15

    To prospectively evaluate feasibility, image quality and diagnostic accuracy of dynamic MR imaging the pelvic floor at 3.0 T in patients with urinary incontinence and to compare these results with those of MRI performed at 1.5 T. Ten patients with the diagnosis of urinary incontinence (clinical symptoms, clinical examination, pelvic ultrasound) were examined with a dynamic balanced FFE (B-FFE) sequence at 1.5 T and 3.0 T on the same day in a randomized order. Spatial (1.5 x 1.5 x 8 mm) and temporal (0.44 s) resolution at 3.0 T were comparable to the 1.5-T B-FFE sequence. Two radiologists assessed visual signal to noise (three-point scale), artefact level (five-point scale) and final MR diagnoses with regard to pelvic floor weakness (independent analysis). The diagnoses obtained at 1.5-T field strength and the results of the clinical tests served as standard of reference. In addition, ROI-based quantitative measurements were performed to assess different tissue contrasts at both field strengths. Data were analyzed for statistical differences by using the Wilcoxon's matched pairs test and the marginal homogeneity test. Visual signal to noise was rated higher at 3.0 T for all ten studies by both radiologists. With regard to artefact level, there was no statistically significant difference between the studies obtained at 3.0 T as compared to the corresponding 1.5-T studies (marginal homogeneity test: p = 0.18 for reviewer 1 and 0.41 for reviewer 2). Mean artefact level was rated minor to moderate by both reviewers for both field strengths (excellent interobserver agreement with Kendall-W value of 0.973). Except for a higher tissue contrast between fat and urethra at 1.5 T, there were no statistically significant differences between tissue contrast at 1.5 T as compared to 3.0 T (Wilcoxon's test). Final MR diagnoses regarding pelvic floor weakness did not differ between 3.0-T and 1.5-T field strength and correlated well with the results of the clinical tests

  15. Dynamic pelvic floor MR imaging at 3 T in patients with clinical signs of urinary incontinence-preliminary results

    International Nuclear Information System (INIS)

    Morakkabati-Spitz, Nuschin; Willinek, Winfried A.; Traeber, Frank; Jaeger, Ursula; Schild, Hans H.; Gieseke, Juergen; Bastian, Patrick J.; Schmitz, Bettina; Mueller, Stefan C.

    2008-01-01

    To prospectively evaluate feasibility, image quality and diagnostic accuracy of dynamic MR imaging the pelvic floor at 3.0 T in patients with urinary incontinence and to compare these results with those of MRI performed at 1.5 T. Ten patients with the diagnosis of urinary incontinence (clinical symptoms, clinical examination, pelvic ultrasound) were examined with a dynamic balanced FFE (B-FFE) sequence at 1.5 T and 3.0 T on the same day in a randomized order. Spatial (1.5 x 1.5 x 8 mm) and temporal (0.44 s) resolution at 3.0 T were comparable to the 1.5-T B-FFE sequence. Two radiologists assessed visual signal to noise (three-point scale), artefact level (five-point scale) and final MR diagnoses with regard to pelvic floor weakness (independent analysis). The diagnoses obtained at 1.5-T field strength and the results of the clinical tests served as standard of reference. In addition, ROI-based quantitative measurements were performed to assess different tissue contrasts at both field strengths. Data were analyzed for statistical differences by using the Wilcoxon's matched pairs test and the marginal homogeneity test. Visual signal to noise was rated higher at 3.0 T for all ten studies by both radiologists. With regard to artefact level, there was no statistically significant difference between the studies obtained at 3.0 T as compared to the corresponding 1.5-T studies (marginal homogeneity test: p = 0.18 for reviewer 1 and 0.41 for reviewer 2). Mean artefact level was rated minor to moderate by both reviewers for both field strengths (excellent interobserver agreement with Kendall-W value of 0.973). Except for a higher tissue contrast between fat and urethra at 1.5 T, there were no statistically significant differences between tissue contrast at 1.5 T as compared to 3.0 T (Wilcoxon's test). Final MR diagnoses regarding pelvic floor weakness did not differ between 3.0-T and 1.5-T field strength and correlated well with the results of the clinical tests. Dynamic

  16. Diffusion-weighted MR imaging of cystic lesions of neurocysticercosis: a preliminary study

    International Nuclear Information System (INIS)

    Raffin, Luciana S.; Bacheschi, Luiz A.; Machado, Luis R.; Nobrega, Jose P.S.; Coelho, Christina; Leite, Claudia C.

    2001-01-01

    Neurocysticercosis is an endemic disease in some developing countries. It has pleomorfic clinical and imaging findings, which are variable from patient to patient. In this preliminary note, we studied the magnetic resonance diffusion-weighted images of sixteen patients presenting with cystic lesions of this disease diagnosed by clinical and laboratorial findings. All the lesions had hypointense signal and the similar apparent diffusion coefficient values as the cerebrospinal fluid. (author)

  17. Preliminary results from NOAMP deep drifting floats

    International Nuclear Information System (INIS)

    Ollitrault, M.

    1989-01-01

    This paper is a very brief and preliminary outline of first results obtained with deep SOFAR floats in the NOAMP area. The work is now going toward more precise statistical estimations of mean and variable currents, together with better tracking to resolve submesoscales and estimate diffusivities due to mesoscale and smaller scale motions. However the preliminary results confirm that the NOAMP region (and surroundings) has a deep mesoscale eddy field that is considerably more energetic that the mean field (r.m.s. velocities are of order 5 cm s -1 ), although both values are diminished compared to the western basin. A data report containing trajectories and statistics is scheduled to be published by IFREMER in the near future. The project main task is to especially study the dispersion of radioactive substances

  18. Characterization of Fine Metal Particles Derived from Shredded WEEE Using a Hyperspectral Image System: Preliminary Results

    Science.gov (United States)

    Candiani, Gabriele; Picone, Nicoletta; Pompilio, Loredana; Pepe, Monica; Colledani, Marcello

    2017-01-01

    Waste of electric and electronic equipment (WEEE) is the fastest-growing waste stream in Europe. The large amount of electric and electronic products introduced every year in the market makes WEEE disposal a relevant problem. On the other hand, the high abundance of key metals included in WEEE has increased the industrial interest in WEEE recycling. However, the high variability of materials used to produce electric and electronic equipment makes key metals’ recovery a complex task: the separation process requires flexible systems, which are not currently implemented in recycling plants. In this context, hyperspectral sensors and imaging systems represent a suitable technology to improve WEEE recycling rates and the quality of the output products. This work introduces the preliminary tests using a hyperspectral system, integrated in an automatic WEEE recycling pilot plant, for the characterization of mixtures of fine particles derived from WEEE shredding. Several combinations of classification algorithms and techniques for signal enhancement of reflectance spectra were implemented and compared. The methodology introduced in this study has shown characterization accuracies greater than 95%. PMID:28505070

  19. Jovian seismology: preliminary results of the SYMPA instrument

    Science.gov (United States)

    Gaulme, P.; Schmider, F. X.; Gay, J.; Jacob, C.; Jeanneaux, F.; Alvarez, M.; Reyes, M.; Valtier, J. C.; Fossat, E.; Palle, P. L.; Belmonte, J. C.; Gelly, B.

    2006-06-01

    Jupiter's internal structure is poorly known (Guillot et al. 2004). Seismology is a powerful tool to investigate the internal structure of planets and stars, by analyzing how acoustic waves propagate. Mosser (1997) and Gudkova & Zarkhov (1999) showed that the detection and the identification of non-radial modes up to degree ℓ=25 can constrain strongly the internal structure. SYMPA is a ground-based network project dedicated to the Jovian oscillations (Schmider et al. 2002). The instrument is composed of a Mach-Zehnder interferometer producing four interferograms of the planetary spectrum. The combination of the four images in phase quadrature allows the reconstruction of the incident light phase, which is related to the Doppler shift generated by the oscillations. Two SYMPA instruments were built at the Nice university and were used simultaneously during two observation campaigns, in 2004 and 2005, at the San Pedro Martir observatory (Mexico) and the Teide observatory (Las Canarias). We will present for the first time the data processing and the preliminary results of the experiment.

  20. Prospective economical evaluation of the image guided radiotherapy (I.G.R.T.) applied to prostate cancers. Preliminary results of the study 'program to support innovative and costly techniques (S.t.i.c.)-I.G.R.T

    International Nuclear Information System (INIS)

    Pommier, P.; Morelle, M.; Remonnay, R.; Crevoisier, R. de

    2009-01-01

    The preliminary results of the economical analysis of CT-guided radiotherapy use shows on one hand, a significant increase in the length of irradiation sessions related to the image guidance, but also on the other hand a substantial inter centrum variability yet to explore. (N.C.)

  1. Optical fiber sensors for image formation in radiodiagnostic - preliminary essays

    International Nuclear Information System (INIS)

    Carvalho, Cesar C. de; Werneck, Marcelo M.

    1998-01-01

    This work describes preliminary experiments that will bring subsidies to analyze the capability to implement a system able to capture radiological images with new sensor system, comprised by FOs scanning process and I-CCD camera. These experiments have the main objective to analyze the optical response from FOs bundle, with several typos of scintillators associated with them, when it is submitted to medical x-rays exposition. (author)

  2. Comparison of Ga-68 DOTA-TATE and Ga-68 DOTA-LAN PET/CT imaging in the same patient group with neuroendocrine tumours: preliminary results.

    Science.gov (United States)

    Demirci, Emre; Ocak, Meltem; Kabasakal, Levent; Araman, Ahmet; Ozsoy, Yildiz; Kanmaz, Bedii

    2013-08-01

    Recent studies have suggested that PET imaging with Ga-68-labelled DOTA-somatostatin analogues such as octreotide and octreotate is useful in diagnosing neuroendocrine tumours (NETs) and has superior value over both computed tomography and planar and SPECT somatostatin receptor scintigraphy. The aim of the present study was to evaluate the role of Ga-68 DOTA-lanreotide (Ga-68-DOTA-LAN) in patients with somatostatin receptor (sst)-expressing tumours and to compare the results of Ga-68 DOTA-D-Phe1-Tyr3-octreotate (Ga-68-DOTA-TATE) in the same patient population. Twelve patients with NETs who were referred to our department for somatostatin receptor scintigraphy were included in the study. There were four patients with well-differentiated neuroendocrine tumour (WDNET) grade 1, two patients with WDNET grade 2, and three patients with poorly differentiated neuroendocrine carcinoma (PDNEC) grade 3. There was also one patient with medullary thyroid cancer, one patient with meningioma and one patient with MEN-1. All patients underwent two consecutive PET imaging studies with Ga-68-DOTA-TATE and Ga-68 DOTA-LAN. All images were evaluated visually, and maximum standardized uptake value was calculated for quantitative evaluation. On visual examination of maximum intensity projection images, GA-68 DOTA-LAN was seen to have high background activity and high bone marrow uptake. Both tracers defined 67 lesions. Ga-68 DOTA-TATE images revealed 63 (94%) clearly defined lesions, missing four lesions. In contrast, Ga-68 DOTA-LAN images defined only 23 (44%) lesions, missing 44 (56%) lesions. Thirty-two bone lesions were detected on Ga-68-DOTA-TATE images. Among them, only 11 (34%) were positive on Ga-68 DOTA-LAN images, whereas 21 (66%) were negative. When we evaluated liver, mediastinum and gastrointestinal tract lesions, Ga-68 DOTA-LAN was seen to be positive for 12 (34%) lesions and negative for 23 (66%) lesions. Although the results are preliminary, the image quality obtained by

  3. The friction of polymers around Tg,Tm : Preliminary results

    DEFF Research Database (Denmark)

    Sivebæk, Ion Marius; Samoilov, V N; Persson, B N J

    We present Molecular Dynamics calculations involving polymers of different lengths. Polymers with lengths from 20 to 1400 carbon atoms are considered. The systems are able to simulate friction between polymer surfaces and polymer against metal. The results we present are very preliminary and they......We present Molecular Dynamics calculations involving polymers of different lengths. Polymers with lengths from 20 to 1400 carbon atoms are considered. The systems are able to simulate friction between polymer surfaces and polymer against metal. The results we present are very preliminary...

  4. Fast, free-breathing, in vivo fetal imaging using time-resolved 3D MRI technique: preliminary results

    OpenAIRE

    Liu, Jing; Glenn, Orit A.; Xu, Duan

    2014-01-01

    Fetal MR imaging is very challenging due to the movement of fetus and the breathing motion of the mother. Current clinical protocols involve quick 2D scouting scans to determine scan plane and often several attempts to reorient the scan plane when the fetus moves. This makes acquisition of fetal MR images clinically challenging and results in long scan times in order to obtain images that are of diagnostic quality. Compared to 2D imaging, 3D imaging of the fetus has many advantages such as hi...

  5. Archaeogeophysical investigations in Tiwanaku: preliminary results

    Science.gov (United States)

    Masini, Nicola; Sileo, Maria; Lasaponara, Rosa; Leucci, Giovanni; Orefici, Giuseppe; Rizzo, Enzo

    2017-04-01

    -1450) Tiwanaku was characterized by the resurgence of regional identities and polities In spite of the rich archaeological record numerous issues, related to the function and the extension of Tiwanaku, need to be investigated especially in the monumental core which includes the pyramid of Akapana, and other ceremonial places such Kalasasaya, Putuni and Kantatallita. To this aims some geophysical investigations were performed in 2009 and 2014 in the context of multidisciplinary research including the use of satellite remote sensing [8]. This paper deals with the discussion of preliminary results of geomagnetic and GPR investigations, some of which have been verified by trial archaeological excavations which have unearthed some buried structures, improving the knowledge of the ceremonial areas of Tiwanaku. References [1] Lasaponara R., Leucci G., Masini N., Persico R., Scardozzi G., Towards an operative use of remote sensing for exploring the past using satellite data: The case study of Hierapolis (Turkey), Remote sensing of Environment, 174 (2016) : 148-164, doi:10.1016/j.rse.2015.12.016 [2] Masini N., Lasaponara R., Rizzo E., Orefici G. 2012. Integrated Remote Sensing Approach in Cahuachi (Peru): Studies and Results of the ITACA Mission (2007-2010), In: Lasaponara R., Masini N. (Eds) 2012, Satellite Remote Sensing: a new tool for Archaeology, Springer, Verlag Berlin Heidelberg, ISBN 978-90-481-8800-0, doi: 10.1007/978-90-481-8801-7_14; pp. 307-344 [3] Rizzo E., Masini N., Lasaponara R., Orefici G. 2010, ArchaeoGeophysical methods in the Templo del Escalonado (Cahuachi, Nasca, Perù), Near Surface Geophysics 8 (5), 433-439, doi:10.3997/1873-0604.2010030 [4] Masini N., Rizzo E., Lasaponara R., and Orefici G. 2008, Integrated remote sensing techniques for the detection of buried archaeological adobe structures: preliminary results in Cahuachi (Peru), Advances in Geosciences, 19, 75-82 [5] Lasaponara R., Leucci G., Masini N., Persico R. 2014. Investigating archaeological looting

  6. French 900 MWe PWR PSA preliminary results

    International Nuclear Information System (INIS)

    Lanore, J.M.; Brisbois, J.

    1988-10-01

    A PSA is performed by the Safety Assessment Department of CEA for a 900 MWe standardized plant. The paper presents the objectives, the scope of the study and the relative preliminary results. Some general insights are drawn, especially the benefit related to the implementation of emergency procedures

  7. Digital subtraction angiography of lower limb arteries using and automatic table translation. Feasibility. Preliminary results

    International Nuclear Information System (INIS)

    Seka, R.; Amiel, M.; Boller, A.; Chapelon, C.; Clermont, A.; Revel, D.; Pinet, F.

    1988-01-01

    Digital subtraction angiography (DSA) as a method of evaluating lower limb arteries required examination of one limb at a time up to now. Moreover repeated injections of contrast material were necessary. This problem was mainly due to the relative small image intensifier field available and to the difficulty of repositionning the patient between mask and image acquisition. The preliminary results obtained with 24 patients studied on angiographic unit equipped with: a DSA system (DG 300-CGR) using 512x512 matrix size, an angiographic table (Angix M 200) allowing an automatic sequantial translation, a removable image intensifier using a 16 inch field below the table, are reported. Thus, all those characteristics allow DSA of lower limb arteries. Only one injection of contrast material (Ioxaglate: 80 ml at 8-10 ml/second) was used per procedure. This, usually, allows good quality examination of lower limb arteries [fr

  8. Danish Anaesthesia Allergy Centre - preliminary results

    DEFF Research Database (Denmark)

    Garvey, L H; Roed-Petersen, J; Menné, T

    2001-01-01

    BACKGROUND: Anaphylactoid reactions in anaesthesia are rare and should ideally be investigated in specialist centres. At Gentofte University Hospital, we established such a centre in 1998 as a joint venture between the Departments of Anaesthesiology and Dermatology. We present the methodology...... for chlorhexidine. Only one patient has tested positive to a neuromuscular blocking drug (NMBD) so far. DISCUSSION: Our preliminary results appear to differ in two ways from results usually found in this field. Firstly, only one patient has tested positive for a NMBD and secondly, we have had four patients...

  9. Preliminary Results of a New Auxiliary Mechatronic Near-Field Radar System to 3D Mammography for Early Detection of Breast Cancer

    Directory of Open Access Journals (Sweden)

    Ashkan Ghanbarzadeh Dagheyan

    2018-01-01

    Full Text Available Accurate and early detection of breast cancer is of high importance, as it is directly associated with the patients’ overall well-being during treatment and their chances of survival. Uncertainties in current breast imaging methods can potentially cause two main problems: (1 missing newly formed or small tumors; and (2 false alarms, which could be a source of stress for patients. A recent study at the Massachusetts General Hospital (MGH indicates that using Digital Breast Tomosynthesis (DBT can reduce the number of false alarms, when compared to conventional mammography. Despite the image quality enhancement DBT provides, the accurate detection of cancerous masses is still limited by low radiological contrast (about 1% between the fibro-glandular tissue and affected tissue at X-ray frequencies. In a lower frequency region, at microwave frequencies, the contrast is comparatively higher (about 10% between the aforementioned tissues; yet, microwave imaging suffers from low spatial resolution. This work reviews conventional X-ray breast imaging and describes the preliminary results of a novel near-field radar imaging mechatronic system (NRIMS that can be fused with the DBT, in a co-registered fashion, to combine the advantages of both modalities. The NRIMS consists of two antipodal Vivaldi antennas, an XY positioner, and an ethanol container, all of which are particularly designed based on the DBT physical specifications. In this paper, the independent performance of the NRIMS is assessed by (1 imaging a bearing ball immersed in sunflower oil and (2 computing the heat Specific Absorption Rate (SAR due to the electromagnetic power transmitted into the breast. The preliminary results demonstrate that the system is capable of generating images of the ball. Furthermore, the SAR results show that the system complies with the standards set for human trials. As a result, a configuration based on this design might be suitable for use in realistic clinical

  10. The preliminary results: Internal seismic velocity structure imaging beneath Mount Lokon

    Energy Technology Data Exchange (ETDEWEB)

    Firmansyah, Rizky, E-mail: rizkyfirmansyah@hotmail.com [Geophysical Engineering, Faculty of Mining and Petroleum Engineering, Institut Teknologi Bandung, Bandung, 40132 (Indonesia); Nugraha, Andri Dian, E-mail: nugraha@gf.itb.ac.id [Global Geophysical Group, Faculty of Mining and Petroleum Engineering, Institut Teknologi Bandung, Bandung, 40132 (Indonesia); Kristianto, E-mail: kris@vsi.esdm.go.id [Center for Volcanology and Geological Hazard Mitigation (CVGHM), Geological Agency, Bandung, 40122 (Indonesia)

    2015-04-24

    Historical records that before the 17{sup th} century, Mount Lokon had been dormant for approximately 400 years. In the years between 1350 and 1400, eruption ever recorded in Empung, came from Mount Lokon’s central crater. Subsequently, in 1750 to 1800, Mount Lokon continued to erupt again and caused soil damage and fall victim. After 1949, Mount Lokon dramatically increased in its frequency: the eruption interval varies between 1 – 5 years, with an average interval of 3 years and a rest interval ranged from 8 – 64 years. Then, on June 26{sup th}, 2011, standby alert set by the Center for Volcanology and Geological Hazard Mitigation. Peak activity happened on July 4{sup th}, 2011 that Mount Lokon erupted continuously until August 28{sup th}, 2011. In this study, we carefully analyzed micro-earthquakes waveform and determined hypocenter location of those events. We then conducted travel time seismic tomographic inversion using SIMULPS12 method to detemine Vp, Vs and Vp/Vs ratio structures beneath Lokon volcano in order to enhance our subsurface geological structure. During the tomographic inversion, we started from 1-D seismic velocities model obtained from VELEST33 method. Our preliminary results show low Vp, low Vs, and high Vp/Vs are observed beneath Mount Lokon-Empung which are may be associated with weak zone or hot material zones. However, in this study we used few station for recording of micro-earthquake events. So, we suggest in the future tomography study, the adding of some seismometers in order to improve ray coverage in the region is profoundly justified.

  11. Preliminary Experience with Small Animal SPECT Imaging on Clinical Gamma Cameras

    Directory of Open Access Journals (Sweden)

    P. Aguiar

    2014-01-01

    Full Text Available The traditional lack of techniques suitable for in vivo imaging has induced a great interest in molecular imaging for preclinical research. Nevertheless, its use spreads slowly due to the difficulties in justifying the high cost of the current dedicated preclinical scanners. An alternative for lowering the costs is to repurpose old clinical gamma cameras to be used for preclinical imaging. In this paper we assess the performance of a portable device, that is, working coupled to a single-head clinical gamma camera, and we present our preliminary experience in several small animal applications. Our findings, based on phantom experiments and animal studies, provided an image quality, in terms of contrast-noise trade-off, comparable to dedicated preclinical pinhole-based scanners. We feel that our portable device offers an opportunity for recycling the widespread availability of clinical gamma cameras in nuclear medicine departments to be used in small animal SPECT imaging and we hope that it can contribute to spreading the use of preclinical imaging within institutions on tight budgets.

  12. Preliminary results from the hierarchical glitch pipeline

    International Nuclear Information System (INIS)

    Mukherjee, Soma

    2007-01-01

    This paper reports on the preliminary results obtained from the hierarchical glitch classification pipeline on LIGO data. The pipeline that has been under construction for the past year is now complete and end-to-end tested. It is ready to generate analysis results on a daily basis. The details of the pipeline, the classification algorithms employed and the results obtained with one days analysis on the gravitational wave and several auxiliary and environmental channels from all three LIGO detectors are discussed

  13. Cognitive Task Analysis of Business Jet Pilots' Weather Flying Behaviors: Preliminary Results

    Science.gov (United States)

    Latorella, Kara; Pliske, Rebecca; Hutton, Robert; Chrenka, Jason

    2001-01-01

    This report presents preliminary findings from a cognitive task analysis (CTA) of business aviation piloting. Results describe challenging weather-related aviation decisions and the information and cues used to support these decisions. Further, these results demonstrate the role of expertise in business aviation decision-making in weather flying, and how weather information is acquired and assessed for reliability. The challenging weather scenarios and novice errors identified in the results provide the basis for experimental scenarios and dependent measures to be used in future flight simulation evaluations of candidate aviation weather information systems. Finally, we analyzed these preliminary results to recommend design and training interventions to improve business aviation decision-making with weather information. The primary objective of this report is to present these preliminary findings and to document the extended CTA methodology used to elicit and represent expert business aviator decision-making with weather information. These preliminary findings will be augmented with results from additional subjects using this methodology. A summary of the complete results, absent the detailed treatment of methodology provided in this report, will be documented in a separate publication.

  14. Imaging Arterial Fibres Using Diffusion Tensor Imaging—Feasibility Study and Preliminary Results

    Directory of Open Access Journals (Sweden)

    Kerskens Christian

    2010-01-01

    Full Text Available Abstract MR diffusion tensor imaging (DTI was used to analyze the fibrous structure of aortic tissue. A fresh porcine aorta was imaged at 7T using a spin echo sequence with the following parameters: matrix 128 128 pixel; slice thickness 0.5 mm; interslice spacing 0.1 mm; number of slices 16; echo time 20.3 s; field of view 28 mm 28 mm. Eigenvectors from the diffusion tensor images were calculated for the central image slice and the averaged tensors and the eigenvector corresponding to the largest eigenvalue showed two distinct angles corresponding to near and to the transverse plane of the aorta. Fibre tractography within the aortic volume imaged confirmed that fibre angles were oriented helically with lead angles of and . The findings correspond to current histological and microscopy data on the fibrous structure of aortic tissue, and therefore the eigenvector maps and fibre tractography appear to reflect the alignment of the fibers in the aorta. In view of current efforts to develop noninvasive diagnostic tools for cardiovascular diseases, DTI may offer a technique to assess the structural properties of arterial tissue and hence any changes or degradation in arterial tissue.

  15. Preliminary Cluster Size and Efficiencies results of CMS RPC at GIF++

    CERN Document Server

    Gonzalez Blanco Gonzalez, Genoveva

    2016-01-01

    A brief description and first preliminary results of the Efficiencies and Cluster Size measurements of the CMS Resistive Plate Chambers, will be presented inside the Gamma Irradiation Facility GIF++ at CERN. Preliminary studies that sets the base performance measurements of CMS RPC for starting aging studies.

  16. Aid in the detection of myocardial perfusion abnormality utilizing SPECT atlas and images registration: preliminary results

    International Nuclear Information System (INIS)

    Padua, Rodrigo Donizete Santana de; Oliveira, Lucas Ferrari de; Marques, Paulo Mazzoncini de Azevedo; Groote, Jean-Jacques Georges Soares de; Castro, Adelson Antonio de; Ana, Lauro Wichert; Simoes, Marcus Vinicius

    2008-01-01

    To develop an atlas of myocardial perfusion scintigraphy and evaluating its applicability in computer-aided detection of myocardial perfusion defects in patients with ischemic heart disease. The atlas was created with rest-stress myocardial perfusion scintigraphic images of 20 patients of both genders with low probability of coronary artery disease and considered as normal by two experienced observers. Techniques of image registration and mathematical operations on images were utilized for obtaining template images depicting mean myocardial uptake and standard deviation for each gender and physiological condition. Myocardial perfusion scintigraphy images of one male and one female patient were aligned with the corresponding atlas template image, and voxels with myocardial uptake rates two standard deviations below the mean voxel value of the respective region in the atlas template image were highlighted on the tomographic sections and confirmed as perfusion defects by both observe. The present study demonstrated the creation of an atlas of myocardial perfusion scintigraphy with promising results of this tool as an aid in the detection of myocardial perfusion defects. However, further prospective validation with a more representative sample is recommended. (author)

  17. Aid in the detection of myocardial perfusion abnormality utilizing SPECT atlas and images registration: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Padua, Rodrigo Donizete Santana de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Div. de Cardiologia]. E-mail: rodrigo_dsp@hcrp.fmrp.usp.br; Oliveira, Lucas Ferrari de [Universidade Federal de Pelotas (UFPel), RS (Brazil). Inst. de Fisica e Matematica. Dept. de Tecnologia da Informacao; Marques, Paulo Mazzoncini de Azevedo [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Groote, Jean-Jacques Georges Soares de [Instituto de Ensino Superior COC, Ribeirao Preto, SP (Brazil). Lab. of Artifical Intelligence and Applications; Castro, Adelson Antonio de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP, (Brazil). Faculdade de Medicina; Ana, Lauro Wichert [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Simoes, Marcus Vinicius [Universidade de Sao Paulo (USP), Ribeirao Preto, SP, (Brazil). Faculdade de Medicina. Divisao de Cardiologia

    2008-11-15

    To develop an atlas of myocardial perfusion scintigraphy and evaluating its applicability in computer-aided detection of myocardial perfusion defects in patients with ischemic heart disease. The atlas was created with rest-stress myocardial perfusion scintigraphic images of 20 patients of both genders with low probability of coronary artery disease and considered as normal by two experienced observers. Techniques of image registration and mathematical operations on images were utilized for obtaining template images depicting mean myocardial uptake and standard deviation for each gender and physiological condition. Myocardial perfusion scintigraphy images of one male and one female patient were aligned with the corresponding atlas template image, and voxels with myocardial uptake rates two standard deviations below the mean voxel value of the respective region in the atlas template image were highlighted on the tomographic sections and confirmed as perfusion defects by both observe. The present study demonstrated the creation of an atlas of myocardial perfusion scintigraphy with promising results of this tool as an aid in the detection of myocardial perfusion defects. However, further prospective validation with a more representative sample is recommended. (author)

  18. Preliminary study of copper oxide nanoparticles acoustic and magnetic properties for medical imaging

    Science.gov (United States)

    Perlman, Or; Weitz, Iris S.; Azhari, Haim

    2015-03-01

    The implementation of multimodal imaging in medicine is highly beneficial as different physical properties may provide complementary information, augmented detection ability, and diagnosis verification. Nanoparticles have been recently used as contrast agents for various imaging modalities. Their significant advantage over conventional large-scale contrast agents is the ability of detection at early stages of the disease, being less prone to obstacles on their path to the target region, and possible conjunction to therapeutics. Copper ions play essential role in human health. They are used as a cofactor for multiple key enzymes involved in various fundamental biochemistry processes. Extremely small size copper oxide nanoparticles (CuO-NPs) are readily soluble in water with high colloidal stability yielding high bioavailability. The goal of this study was to examine the magnetic and acoustic characteristics of CuO-NPs in order to evaluate their potential to serve as contrast imaging agent for both MRI and ultrasound. CuO-NPs 7nm in diameter were synthesized by hot solution method. The particles were scanned using a 9.4T MRI and demonstrated a concentration dependent T1 relaxation time shortening phenomenon. In addition, it was revealed that CuO-NPs can be detected using the ultrasonic B-scan imaging. Finally, speed of sound based ultrasonic computed tomography was applied and showed that CuO-NPs can be clearly imaged. In conclusion, the preliminary results obtained, positively indicate that CuO-NPs may be imaged by both MRI and ultrasound. The results motivate additional in-vivo studies, in which the clinical utility of fused images derived from both modalities for diagnosis improvement will be studied.

  19. Imaging Arterial Fibres Using Diffusion Tensor Imaging—Feasibility Study and Preliminary Results

    Directory of Open Access Journals (Sweden)

    Ciaran K. Simms

    2010-01-01

    Full Text Available MR diffusion tensor imaging (DTI was used to analyze the fibrous structure of aortic tissue. A fresh porcine aorta was imaged at 7T using a spin echo sequence with the following parameters: matrix 128 × 128 pixel; slice thickness 0.5 mm; interslice spacing 0.1 mm; number of slices 16; echo time 20.3 s; field of view 28 mm × 28 mm. Eigenvectors from the diffusion tensor images were calculated for the central image slice and the averaged tensors and the eigenvector corresponding to the largest eigenvalue showed two distinct angles corresponding to near 0∘ and 180∘ to the transverse plane of the aorta. Fibre tractography within the aortic volume imaged confirmed that fibre angles were oriented helically with lead angles of 15±2.5∘ and 175±2.5∘. The findings correspond to current histological and microscopy data on the fibrous structure of aortic tissue, and therefore the eigenvector maps and fibre tractography appear to reflect the alignment of the fibers in the aorta. In view of current efforts to develop noninvasive diagnostic tools for cardiovascular diseases, DTI may offer a technique to assess the structural properties of arterial tissue and hence any changes or degradation in arterial tissue.

  20. Preliminary study of single contrast enhanced dual energy heart imaging using dual-source CT

    International Nuclear Information System (INIS)

    Peng Jin; Zhang Longjiang; Zhou Changsheng; Lu Guangming; Ma Yan; Gu Haifeng

    2009-01-01

    Objective: To evaluate the feasibility and preliminary applications of single contrast enhanced dual energy heart imaging using dual-source CT (DSCT). Methods: Thirty patients underwent dual energy heart imaging with DSCT, of which 6 cases underwent SPECT or DSA within one week. Two experienced radiologists assessed image quality of coronary arteries and iodine map of myocardium. and correlated the coronary artery stenosis with the perfusion distribution of iodine map. Results: l00% (300/300) segments reached diagnostic standards. The mean score of image for all patients was 4.68±0.57. Mural coronary artery was present in 10 segments in S cases, atherosclerotic plaques in 32 segments in 12 cases, of which 20 segments having ≥50% stenosis, 12 segments ≤50% stenosis; dual energy CT coronary angiography was consistent with the DSA in 3 patients. 37 segmental perfusion abnormalities on iodine map were found in 15 cases, including 28 coronary blood supply segment narrow segment and 9 no coronary stenosis (including three negative segments in SPECD. Conclusion: Single contrast enhanced dual energy heart imaging can provide good coronary artery and myocardium perfusion images in the patients with appropriate heart rate, which has a potential to be used in the clinic and further studies are needed. (authors)

  1. Using VIIRS Day/Night Band to Measure Electricity Supply Reliability: Preliminary Results from Maharashtra, India

    Directory of Open Access Journals (Sweden)

    Michael L. Mann

    2016-08-01

    Full Text Available Unreliable electricity supplies are common in developing countries and impose large socio-economic costs, yet precise information on electricity reliability is typically unavailable. This paper presents preliminary results from a machine-learning approach for using satellite imagery of nighttime lights to develop estimates of electricity reliability for western India at a finer spatial scale. We use data from the Visible Infrared Imaging Radiometer Suite (VIIRS onboard the Suomi National Polar Partnership (SNPP satellite together with newly-available data from networked household voltage meters. Our results point to the possibilities of this approach as well as areas for refinement. With currently available training data, we find a limited ability to detect individual outages identified by household-level measurements of electricity voltage. This is likely due to the relatively small number of individual outages observed in our preliminary data. However, we find that the approach can estimate electricity reliability rates for individual locations fairly well, with the predicted versus actual regression yielding an R2 > 0.5. We also find that, despite the after midnight overpass time of the SNPP satellite, the reliability estimates derived are representative of daytime reliability.

  2. Preliminary Image Map of the 2007 Witch Fire Perimeter, Santa Ysabel Quadrangle, San Diego County, California

    Science.gov (United States)

    Clark, Perry S.; Scratch, Wendy S.; Bias, Gaylord W.; Stander, Gregory B.; Sexton, Jenne L.; Krawczak, Bridgette J.

    2008-01-01

    In the fall of 2007, wildfires burned out of control in southern California. The extent of these fires encompassed large geographic areas that included a variety of landscapes from urban to wilderness. The U.S. Geological Survey National Geospatial Technical Operations Center (NGTOC) is currently (2008) developing a quadrangle-based 1:24,000-scale image map product. One of the concepts behind the image map product is to provide an updated map in electronic format to assist with emergency response. This image map is one of 55 preliminary image map quadrangles covering the areas burned by the southern California wildfires. Each map is a layered, geo-registered Portable Document Format (.pdf) file. For more information about the layered geo-registered .pdf, see the readme file (http://pubs.usgs.gov/of/2008/1029/downloads/CA_Agua_Dulce_of2008-1029_README.txt). To view the areas affected and the quadrangles mapped in this preliminary project, see the map index (http://pubs.usgs.gov/of/2008/1029/downloads/CA_of2008_1029-1083_index.pdf) provided with this report.

  3. Preliminary Image Map of the 2007 Buckweed Fire Perimeter, Agua Dulce Quadrangle, Los Angeles County, California

    Science.gov (United States)

    Clark, Perry S.; Scratch, Wendy S.; Bias, Gaylord W.; Stander, Gregory B.; Sexton, Jenne L.; Krawczak, Bridgette J.

    2008-01-01

    In the fall of 2007, wildfires burned out of control in southern California. The extent of these fires encompassed large geographic areas that included a variety of landscapes from urban to wilderness. The U.S. Geological Survey National Geospatial Technical Operations Center (NGTOC) is currently (2008) developing a quadrangle-based 1:24,000-scale image map product. One of the concepts behind the image map product is to provide an updated map in electronic format to assist with emergency response. This image map is one of 55 preliminary image map quadrangles covering the areas burned by the southern California wildfires. Each map is a layered, geo-registered Portable Document Format (.pdf) file. For more information about the layered geo-registered .pdf, see the readme file (http://pubs.usgs.gov/of/2008/1029/downloads/CA_Agua_Dulce_of2008-1029_README.txt). To view the areas affected and the quadrangles mapped in this preliminary project, see the map index (http://pubs.usgs.gov/of/2008/1029/downloads/CA_of2008_1029-1083_index.pdf) provided with this report.

  4. Preliminary results on heavy flavor physics at SLD

    Energy Technology Data Exchange (ETDEWEB)

    Usher, T. [Stanford Univ., CA (United States)

    1994-12-01

    The author reports on preliminary heavy flavor physics results from the SLD detector at the SLAC Linear Collider. Efficient tagging of b{bar b} events is achieved with an impact parameter technique that takes advantage of the small and stable interaction point of the SLC and all charged tracks in Z{sup 0} decays. This technique is applied to samples of Z{sup 0} events collected during the 1992 and 1993 physics runs. Preliminary measurements of the ratio R{sub b} = {Gamma}(Z{sup 0} {yields} b{bar b})/{Gamma}(Z{sup 0} {yields} hadrons) and the average B hadron lifetime <{tau}{sub B}> are reported. In a sample of 27K Z{sup 0} events, values of R{sub b} = 0.235 {+-} 0.006(stat.) {+-} 0.018(syst.) and <{tau}{sub B}> = 1.53 {+-} 0.006(stat.) {+-} 0.018(syst.) are obtained. In addition, the first measurement of the left-right asymmetry A{sub b} is reported. Using a sample of 38K Z{sup 0} events with a luminosity weighted electron polarization of 62%, the author obtains a preliminary value of A{sub b} = 0.94 {+-} 0.006(stat.) {+-} 0.018(syst.).

  5. Upper crustal structure beneath East Java from ambient noise tomography: A preliminary result

    International Nuclear Information System (INIS)

    Martha, Agustya Adi; Widiyantoro, Sri; Cummins, Phil; Saygin, Erdinc; Masturyono

    2015-01-01

    East Java has a fairly complex geological structure. Physiographically East Java can be divided into three zones, i.e. the Southern Mountains zone in the southern part, the Kendeng zone in the middle part, and the Rembang zone in the northern part. Most of the seismic hazards in this region are due to processes in the upper crust. In this study, the Ambient Noise Tomography (ANT) method is used to image the upper crustal structure beneath East Java. We have used seismic waveform data recorded by 8Meteorological, Climatological and Geophysical Agency (BMKG) stationary seismographic stations and 16 portable seismographs installed for 2 to 8 weeks. The data were processed to obtain waveforms fromnoise cross-correlation between pairs of seismographic stations. Our preliminary results indicate that the Kendeng zone, an area of low gravity anomaly, is associated with a low velocity zone. On the other hand, the southern mountain range, which has a high gravity anomaly, is related to a high velocity anomaly as shown by our tomographic images

  6. Upper crustal structure beneath East Java from ambient noise tomography: A preliminary result

    Energy Technology Data Exchange (ETDEWEB)

    Martha, Agustya Adi [Meteorological, Climatological and Geophysical Agency, Jakarta (Indonesia); Graduate Research on Earthquakes and Active Tectonics, Institut Teknologi Bandung, Bandung (Indonesia); Widiyantoro, Sri [Global Geophysics Group, Institut Teknologi Bandung, Bandung (Indonesia); Center for Disaster Mitigation, Institut Teknologi Bandung, Bandung (Indonesia); Cummins, Phil; Saygin, Erdinc [Research School of Earth Sciences, Australian National University, Canberra (Australia); Masturyono [Meteorological, Climatological and Geophysical Agency, Jakarta (Indonesia)

    2015-04-24

    East Java has a fairly complex geological structure. Physiographically East Java can be divided into three zones, i.e. the Southern Mountains zone in the southern part, the Kendeng zone in the middle part, and the Rembang zone in the northern part. Most of the seismic hazards in this region are due to processes in the upper crust. In this study, the Ambient Noise Tomography (ANT) method is used to image the upper crustal structure beneath East Java. We have used seismic waveform data recorded by 8Meteorological, Climatological and Geophysical Agency (BMKG) stationary seismographic stations and 16 portable seismographs installed for 2 to 8 weeks. The data were processed to obtain waveforms fromnoise cross-correlation between pairs of seismographic stations. Our preliminary results indicate that the Kendeng zone, an area of low gravity anomaly, is associated with a low velocity zone. On the other hand, the southern mountain range, which has a high gravity anomaly, is related to a high velocity anomaly as shown by our tomographic images.

  7. Therapy of neuroendocrine carcinoma with Y-90 DOTA- preliminary results

    International Nuclear Information System (INIS)

    Artiko, V.; Obradovic, V.; Nadezda, N.; Djokic, D.; Jankovic, D.; Popovic, B.; Damjanovic, S.; Mikolajczak, R.; Pawlak, D.

    2007-01-01

    Full text: Aim: Cell membrane-specific somatostatin receptors are usually expressed by neuroendocrine tumors. Radiolabelled receptor-binding somatostatin analogues target tissues expressing these receptors and can be used for visualization and treatment. After the localization of tumors bearing somatostatin receptors with 111In or 99mTc labeled somatostatin analogues, in the case of high tumor uptake related to non target tissues, different radioisotopes have been used for their treatment. Thus, application of high doses of 111In- DTPA-octreotide had an impact on improvement of the clinical symptoms, without significant reduction of the tumor mass. However, 90Y somatostatin analogues (DOTA TOC, lanreotide) may be more effective for reduction of the tissue of the larger tumors while 177Lu labeled ones may be applied in smaller tumors. Combination of both of them seems to be the most effective therapy, particularly in tumors bearing both small and large lesions. The aim of this work is presentation of the preliminary results of the therapy of NETs with another octreotide analogue, 90Y DOTA TATE, which so far has been proved to have high therapeutic potential when labeled with 177Lu. Patients and methods: We investigated 7 patients with neuroendocrine tumors (two patients had neuroendocrine pancreatic carcinomas with liver metastases (one of them had metastases in peritoneal lymph nodes), one patient with operated (resected) bronchial carcinoid and liver metastases, three patients with neuroendocrine carcinomas of unknown origin and hepatic metastases (one with skeletal metastases) and one with pancreatic gastrinoma without metastases (surgery was impossible to perform). In all of them, together with other laboratory analyses and imaging methods, scintigraphy with somatostatin analogues was performed (in 3 with 111In Octreoscan and in the other 4 with 99mTc HYNIC TOC) and high tumor uptake was observed. The therapy was performed with 2- 4,5 GBq 90Y DOTA TATE per

  8. A preliminary investigation of the imaging performance of photostimulable phosphor computed radiography using a new design of mammographic quality control test object

    International Nuclear Information System (INIS)

    Cowen, A.R.; Brettle, D.S.; Coleman, N.J.; Parkin, G.J.S.

    1992-01-01

    Leeds Test Object TOR[MAM] has been designed to supplement the current FAXIL mammography test object TOR[MAX]. It contains a range of details that have a more natural radiographic appearance and has been designed as a test that more closely approximates the image quality achieved in clinical mammography. Physical aspects of the design and implementation of TOR[MAM] are presented. The TOR[MAM] has been used in a preliminary physical evaluation of the comparative image qualities produced by conventional (screen-film) and phostostimulable phosphor computed mammography and the results are discussed. TOR[MAX] results are also presented. The influence of digital image processing (enhancement) on the image quality of computed mammograms is also considered. The results presented indicate the sensitivity of TOR[MAM]. (author)

  9. Preliminary results from film boiling destabilisation experiments

    International Nuclear Information System (INIS)

    Naylor, P.

    1984-05-01

    A series of experiments to investigate the triggered destabilisation of film boiling has been undertaken. Film boiling was established on a polished brass rod immersed in water and the effects of various triggers were investigated. Preliminary results are presented and two thresholds have been observed: an impulse threshold below which triggered destabilisation will not occur and a thermal threshold above which film boiling will re-establish following triggered destabilisation. (author)

  10. Iron in hereditary retinal degeneration: PIXE microanalysis Preliminary results

    International Nuclear Information System (INIS)

    Sergeant, C.; Gouget, B.; Llabador, Y.; Simonoff, M.; Yefimova, M.; Courtois, Y.; Jeanny, J.C.

    1999-01-01

    Several types of hereditary retinal degeneration with progressive alteration of photoreceptors exist in men and animals. Recent immunohistochemical results have shown strong degradation of transferrin, the protein responsible for iron transport, in retinas of rats with hereditary retinal degeneration. Freeze-dried thin sections of rat retinas from different stages of the disease, and respective coeval control sections, have been analyzed using nuclear microprobe. In this first part of the study, the rat retinas at post-natal stages of 35 and 45 days have been analyzed. The sample preparation and the post-irradiation staining to determine precisely the retinal layers involved are described. Preliminary results of element distributions (K, Ca, Fe) in the rat retina layers are discussed. A very high content of calcium in the choriocapillaris of dystrophic rat retinas was observed. Preliminary results on iron distribution in the rat retina layers are presented

  11. Preliminary results of the Adone storage ring FEL experiment, LELA

    International Nuclear Information System (INIS)

    Barbini, R.; Vignola, G.; Trillo, S.

    1983-01-01

    A short description of the LELA (Free Electron Laser on Adone) experiment is given. Results on the spontaneous radiation angle and energy spectra and preliminary results on optical gain measurements are also discussed

  12. Preliminary results of testing bioassay analytical performance standards

    International Nuclear Information System (INIS)

    Fisher, D.R.; Robinson, A.V.; Hadley, R.T.

    1983-08-01

    The analytical performance of both in vivo and in vitro bioassay laboratories is being studied to determine the capability of these laboratories to meet the minimum criteria for accuracy and precision specified in the draft ANSI Standard N13.30, Performance Criteria for Radiobioassay. This paper presents preliminary results of the first round of testing

  13. Preliminary test results from a telescope of Hughes pixel arrays at FNAL

    International Nuclear Information System (INIS)

    Jernigan, J.G.; Arens, J.; Vezie, D.; Collins, T.; Krider, J.; Skubic, P.

    1992-09-01

    In December of 1991 three silicon hybrid pixel detectors each having 2.56 x 2.56 pixels 30 μm square, made by the Hughes Aircraft Company, were placed in a high energy muon beam at the Fermi National Accelerator Laboratory. Straight tracks were recorded in these detectors at angles to the normal to the plane of the silicon ranging from 0 to 45 degrees. In this note, preliminary results are presented on the straight through tracks, i.e., those passing through the telescope at normal incidence. Pulse height data, signal-to-noise data, and preliminary straight line fits to the data resulting in residual distributions are presented. Preliminary calculations show spatial resolution of less than 5 μm in two dimensions

  14. MR imaging and MR spectroscopy for characterization of cardiomyopathies in adolescents - preliminary results

    International Nuclear Information System (INIS)

    Beer, M.; Buchner, S.; Fuchs, J.; Machann, W.; Ritter, C.O.; Beissert, M.; Darge, K.; Hahn, D.; Koestler, H.; Wirbelauer, J.

    2007-01-01

    Purpose: Cardiomyopathy is a rare but life-threatening disease in children and adolescents. Recent studies reported morphological, functional or metabolic alterations of the heart. We discuss a combined MR imaging and 31 P MR spectroscopy (MRS) protocol allowing the analysis of interdependencies between these parameters. Since normal values of cardiac MR parameters in this age group are not available, we included studies of age-matched healthy adolescents. Materials and Methods: 2D-CINE was used to assess left ventricular (LV) parameters. Additional 3D-Chemical Shift Imaging (3D-CSI) and Spectral Localization with Optimal Pointspread Function (SLOOP) reconstruction allowed quantification of the cardiac energy metabolism. Patients (n = 4; all male; age 16.8 ± 2.9 years) were included on the basis of an echocardiographic diagnosis of possible cardiomyopathy. The same protocol was applied to healthy young volunteers (n = 4; 1 female, 3 male; age 15.5 ± 0.6 years). Results: The patients had a significantly higher LV mass index compared to the control group (147 ± 41 g/m2 versus 97 ± 16 g/m2; p = 0.04). The other LV parameters (including LV EF with 59 ± 22 % versus 67 ± 10 %) showed no significant differences. The phosphocreatine to adenosine triphosphate ratio (PCr/ATP-ratio) of the patients was reduced to 1.71 ± 0.40 versus 2.44 ± 0.30 (p = 0.01), combined with a tendency towards decreased PCr concentrations of 9.1 ± 2.5 versus 7.9 ± 1.0 mmol/kg. Conclusion: The combination of 31 P MR spectroscopy and MR imaging allows quantitative determination of morphologic, functional and metabolic alterations in adolescents with suspected cardiomyopathy in one examination procedure. The reduction of energy metabolism combined with unaltered global function may indicate a primary role of metabolism in the pathogenesis of cardiomyopathies in adolescents. (orig.)

  15. Connecticut Transit (CTTRANSIT) Fuel Cell Transit Bus: Preliminary Evaluation Results

    Energy Technology Data Exchange (ETDEWEB)

    Chandler, K.; Eudy, L.

    2008-10-01

    This report provides preliminary results from a National Renewable Energy Laboratory evaluation of a protoptye fuel cell transit bus operating at Connecticut Transit in Hartford. Included are descriptions of the planned fuel cell bus demonstration and equipment; early results and agency experience are also provided.

  16. Preliminary results of a PWA of the centrally produced {phi}{phi} system

    Energy Technology Data Exchange (ETDEWEB)

    Marco A. Reyes et al.

    2001-11-02

    The authors present preliminary results of a Partial Wave Analysis of the centrally produced {phi}{phi} system at 800 GeV/c in the reaction pp {yields} p{sub slow} ({phi}{phi})p{sub fast}. The preliminary results with one and two M = 0 waves, indicate that most of the cross section can be described by two waves, with J{sup PC} LS{sup {eta}} = 2{sup 2}02{sup -1}, 0{sup 2}00{sup -1}.

  17. Danish Anaesthesia Allergy Centre - preliminary results

    DEFF Research Database (Denmark)

    Garvey, L H; Roed-Petersen, J; Menné, T

    2001-01-01

    BACKGROUND: Anaphylactoid reactions in anaesthesia are rare and should ideally be investigated in specialist centres. At Gentofte University Hospital, we established such a centre in 1998 as a joint venture between the Departments of Anaesthesiology and Dermatology. We present the methodology...... of in vitro testing and skin testing. Blood samples for tryptase analysis are taken at the time of reaction and a control sample is taken together with samples for specific IgE analysis 2-4 weeks after the reaction. Subsequent skin testing comprises both prick tests and intradermal tests in most cases...... for chlorhexidine. Only one patient has tested positive to a neuromuscular blocking drug (NMBD) so far. DISCUSSION: Our preliminary results appear to differ in two ways from results usually found in this field. Firstly, only one patient has tested positive for a NMBD and secondly, we have had four patients...

  18. Annotating images by mining image search results.

    Science.gov (United States)

    Wang, Xin-Jing; Zhang, Lei; Li, Xirong; Ma, Wei-Ying

    2008-11-01

    Although it has been studied for years by the computer vision and machine learning communities, image annotation is still far from practical. In this paper, we propose a novel attempt at model-free image annotation, which is a data-driven approach that annotates images by mining their search results. Some 2.4 million images with their surrounding text are collected from a few photo forums to support this approach. The entire process is formulated in a divide-and-conquer framework where a query keyword is provided along with the uncaptioned image to improve both the effectiveness and efficiency. This is helpful when the collected data set is not dense everywhere. In this sense, our approach contains three steps: 1) the search process to discover visually and semantically similar search results, 2) the mining process to identify salient terms from textual descriptions of the search results, and 3) the annotation rejection process to filter out noisy terms yielded by Step 2. To ensure real-time annotation, two key techniques are leveraged-one is to map the high-dimensional image visual features into hash codes, the other is to implement it as a distributed system, of which the search and mining processes are provided as Web services. As a typical result, the entire process finishes in less than 1 second. Since no training data set is required, our approach enables annotating with unlimited vocabulary and is highly scalable and robust to outliers. Experimental results on both real Web images and a benchmark image data set show the effectiveness and efficiency of the proposed algorithm. It is also worth noting that, although the entire approach is illustrated within the divide-and conquer framework, a query keyword is not crucial to our current implementation. We provide experimental results to prove this.

  19. King County Metro Battery Electric Bus Demonstration: Preliminary Project Results

    Energy Technology Data Exchange (ETDEWEB)

    2017-05-22

    The U.S. Federal Transit Administration (FTA) funds a variety of research projects that support the commercialization of zero-emission bus technology. To evaluate projects funded through these programs, FTA has enlisted the help of the National Renewable Energy Laboratory (NREL) to conduct third-party evaluations of the technologies deployed under the FTA programs. NREL works with the selected agencies to evaluate the performance of the zero-emission buses compared to baseline conventional buses in similar service. The evaluation effort will advance the knowledge base of zero-emission technologies in transit bus applications and provide 'lessons learned' to aid other fleets in incrementally introducing next generation zero-emission buses into their operations. This report provides preliminary performance evaluation results from a demonstration of three zero-emission battery electric buses at King County Metro in King County, Washington. NREL developed this preliminary results report to quickly disseminate evaluation results to stakeholders. Detailed evaluation results will be published in future reports.

  20. SU-E-I-74: Image-Matching Technique of Computed Tomography Images for Personal Identification: A Preliminary Study Using Anthropomorphic Chest Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Matsunobu, Y; Shiotsuki, K [Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Fukuoka (Japan); Morishita, J [Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, Fukuoka, JP (Japan)

    2015-06-15

    Purpose: Fingerprints, dental impressions, and DNA are used to identify unidentified bodies in forensic medicine. Cranial Computed tomography (CT) images and/or dental radiographs are also used for identification. Radiological identification is important, particularly in the absence of comparative fingerprints, dental impressions, and DNA samples. The development of an automated radiological identification system for unidentified bodies is desirable. We investigated the potential usefulness of bone structure for matching chest CT images. Methods: CT images of three anthropomorphic chest phantoms were obtained on different days in various settings. One of the phantoms was assumed to be an unidentified body. The bone image and the bone image with soft tissue (BST image) were extracted from the CT images. To examine the usefulness of the bone image and/or the BST image, the similarities between the two-dimensional (2D) or threedimensional (3D) images of the same and different phantoms were evaluated in terms of the normalized cross-correlation value (NCC). Results: For the 2D and 3D BST images, the NCCs obtained from the same phantom assumed to be an unidentified body (2D, 0.99; 3D, 0.93) were higher than those for the different phantoms (2D, 0.95 and 0.91; 3D, 0.89 and 0.80). The NCCs for the same phantom (2D, 0.95; 3D, 0.88) were greater compared to those of the different phantoms (2D, 0.61 and 0.25; 3D, 0.23 and 0.10) for the bone image. The difference in the NCCs between the same and different phantoms tended to be larger for the bone images than for the BST images. These findings suggest that the image-matching technique is more useful when utilizing the bone image than when utilizing the BST image to identify different people. Conclusion: This preliminary study indicated that evaluating the similarity of bone structure in 2D and 3D images is potentially useful for identifying of an unidentified body.

  1. SU-E-I-74: Image-Matching Technique of Computed Tomography Images for Personal Identification: A Preliminary Study Using Anthropomorphic Chest Phantoms

    International Nuclear Information System (INIS)

    Matsunobu, Y; Shiotsuki, K; Morishita, J

    2015-01-01

    Purpose: Fingerprints, dental impressions, and DNA are used to identify unidentified bodies in forensic medicine. Cranial Computed tomography (CT) images and/or dental radiographs are also used for identification. Radiological identification is important, particularly in the absence of comparative fingerprints, dental impressions, and DNA samples. The development of an automated radiological identification system for unidentified bodies is desirable. We investigated the potential usefulness of bone structure for matching chest CT images. Methods: CT images of three anthropomorphic chest phantoms were obtained on different days in various settings. One of the phantoms was assumed to be an unidentified body. The bone image and the bone image with soft tissue (BST image) were extracted from the CT images. To examine the usefulness of the bone image and/or the BST image, the similarities between the two-dimensional (2D) or threedimensional (3D) images of the same and different phantoms were evaluated in terms of the normalized cross-correlation value (NCC). Results: For the 2D and 3D BST images, the NCCs obtained from the same phantom assumed to be an unidentified body (2D, 0.99; 3D, 0.93) were higher than those for the different phantoms (2D, 0.95 and 0.91; 3D, 0.89 and 0.80). The NCCs for the same phantom (2D, 0.95; 3D, 0.88) were greater compared to those of the different phantoms (2D, 0.61 and 0.25; 3D, 0.23 and 0.10) for the bone image. The difference in the NCCs between the same and different phantoms tended to be larger for the bone images than for the BST images. These findings suggest that the image-matching technique is more useful when utilizing the bone image than when utilizing the BST image to identify different people. Conclusion: This preliminary study indicated that evaluating the similarity of bone structure in 2D and 3D images is potentially useful for identifying of an unidentified body

  2. Structural investigations of biogenic iron oxide samples. Preliminary results

    International Nuclear Information System (INIS)

    Balasoiu, M.; Kuklin, A.I.; Orelovich, O.L.; Kovalev, Yu.S.; Arzumanyan, G.M.; Kurkin, T.S.; Stolyar, S.V.; Iskhakov, R.S.; Rajkher, Yu.L.

    2008-01-01

    Some preliminary results on morphology and structure of iron oxide particles formed inside Klebsiella oxytoca bacteria are presented. In particular, by means of optical microscopy, scanning electron microscopy and small-angle X-ray scattering the effect of the bacteria age (the duration of growth) on the nanoparticles properties is studied

  3. MR diffusion weighted imaging of the prostate adenocarcinoma after endocrinotherapy: preliminary results

    International Nuclear Information System (INIS)

    Chen Zhiqiang; Wang Xiaoying; Li Feiyu; Guo Xuemei; Jiang Xuexiang; Guo Yulin

    2007-01-01

    Objective: To assess the changes of the apparent diffusion coefficient (ADC) values of cancerous and noncancerous regions of prostate peripheral zone in prostate cancer patients with and without endocrinotherapy. Methods: Diffusion-weighted echo-planar imaging (EPI) were performed in 32 patients with diagnosed prostate cancer, including 18 patients who were treated with endocrinotherapy over 6 months and 14 untreated matched control patients. According to the pathological results obtained by ultrasound guided biopsy, the locations of the prostate cancerous regions were marked at one or more of the sextants. The ADC values of the bladder and the obturator internus were also measured. Results: The mean ADC values of cancerous and noncancerous regions in 14 untreated controls were (1.22±0.25) x 10 -3 , (1.59 ± 0.19) x 10 -3 mm 2 /s, respectively (t=7.03, P -3 mm 2 /s in noncancerous regions, but increased to (1.46 ± 0.30) x 10 -3 mm 2 /s in cancerous regions. There still had significant difference between the cancerous and the noncancerous regions (t=2.46, P 0.05), in bladder and the obturator internus (t=0.48, 1.64; P>0.05). Conclusion: Measurement of ADCs might be useful to evaluate the efficacy of endocrinotherapy for patients with prostate cancer. (authors)

  4. The preliminary results of the diagnosis of pituitary diseases using 13N-NH3 PET dynamic imaging

    International Nuclear Information System (INIS)

    Zhang Xiangsong; Chen Hongmei; Yang Huazhang; Tang Anwu; Qiao Suixian

    2002-01-01

    Objective: To preliminarily evaluate the value of 13 N-NH 3 PET dynamic imaging for the diagnosis of pituitary diseases. Methods: The 13 N-NH 3 PET dynamic imaging was performed on 2 patients with pituitary microadenoma and one patient with hypopituitarism, the diagnoses were confirmed by MRI, levels of relative endocrine hormones in blood and clinical presentations. Results: In 2 patients with pituitary microadenoma, the pituitaries were seen in 20 and 30 s after the internal carotid was seen in the dynamic PET images, the upper margins of pituitaries were convex, the heights were 1.75 cm and 1.62 cm, the standard uptake values (SUVs) of pituitaries were 3.96 and 3.28, and the radioactivity ratio of pituitary to thalamus were 1.58 and 1.27. In the patient with hypopituitarism, the pituitary was seen at 3 min after the image of the internal carotid, the image of pituitary was smaller than the normal ones (0.82 cm x 0.83 cm x 1.03 cm), the SUV of pituitary was 1.48, and the radioactivity ratio of pituitary to thalamus was 0.64. Conclusion: The 13 N-NH 3 PET dynamic imaging is useful in diagnosing pituitary microadenoma and hypopituitarism

  5. A pancreas imaging agent-131I-HIPDM: the animal experiment and preliminary clinical application

    International Nuclear Information System (INIS)

    Shao Hesheng

    1988-01-01

    131 I-HIPDM has been used clinically for studying regional cerebral perfusion. The [ 131 I] HIPDM was prepared in a kit. The labelling yields were consistently more than 95%, as analyzed by the TLC-Silica gel. The labelled compound is stable in vitro and in vivo. S D Strain rats (170-220 g) and mice (18-22 g) were used. The pancreatic uptake of [ 131 I] HIPDM is rather slow in mice and rats. At 8 hr after iv, the pancreas activity and the pancreas to liver (P/L) ratio are highest in mice and rats. The effect of carrier loading dose from 0.010 to 6.0 mg/kg on blodistribution in mice has been studied. The liver uptake was increased by adding carrier HIPDM. The result indicates that administration between 0.010 and 0.05 mg/kg carrier dose is most suitable for the pancreas imaging. Gamma camera imaging of dog at 6 hr after iv with 300 μCi [ 131 I] HIPMD, 0.05 mg/kg body weight showed clear pancreas image. The P/L ratio of the dog is 0.40. Preliminary clinical tests were satisfactory. Using 1 to 1.5 mCi of [ 131 I] HIPDM, 0.05 mg/kg, the pancreas imaging was operated in 4 cases of volunteers and pancreas cyst respectively with the good diagnostic quality. The authors are of the opinion that this pancreas imaging agent may have potential value for routine use

  6. Remote sensing using hydroacoustics preliminary results

    International Nuclear Information System (INIS)

    Hunt, G.; Patrick, P.H.; Sim, B.

    1989-01-01

    A laboratory investigation was conducted to determine the capability and accuracy of a dual beam sonar system in classifying various targets. The ability to classify fish and/or distinguish fish from debris is essential if hydroacoustics are ever to be used truly remotely for hydroelectric power plant fish passage facilities. Preliminary results indicated that considerable filtering was occurring in the sonar sounder which limited its use in target classification. A wideband sonar detection module was developed which allowed for a more detailed reflected signal which probably will be necessary for fish identification. Another advantage that this modification appears to have over the existing system is an improved spatial resolution of targets, which can be significant if biomass estimates are based on echo counting techniques rather than echo integration ones. Based on the results, it may be possible to filter out or remove the influence of air bubbles in echo returns. As a result echo counts could more accurately be defined as fish counts. Target strengths of sturgeon were estimated using both the modified and original sounder. 12 refs., 11 figs., 2 tabs

  7. Preliminary results of statistical dynamic experiments on a heat exchanger

    International Nuclear Information System (INIS)

    Corran, E.R.; Cummins, J.D.

    1962-10-01

    The inherent noise signals present in a heat exchanger have been recorded and analysed in order to determine some of the statistical dynamic characteristics of the heat exchanger. These preliminary results show that the primary side temperature frequency response may be determined by analysing the inherent noise. The secondary side temperature frequency response and cross coupled temperature frequency responses between primary and secondary are poorly determined because of the presence of a non-stationary noise source in the secondary circuit of this heat exchanger. This may be overcome by correlating the dependent variables with an externally applied noise signal. Some preliminary experiments with an externally applied random telegraph type of signal are reported. (author)

  8. Sub-millimeter planar imaging with positron emitters: EGS4 code simulation and experimental results

    International Nuclear Information System (INIS)

    Bollini, D.; Del Guerra, A.; Di Domenico, G.

    1996-01-01

    Experimental data for Planar Imaging with positron emitters (pulse height, efficiency and spatial resolution) obtained with two matrices of 25 crystals (2 x 2 x 30 mm 3 each) of YAP:Ce coupled with a Position Sensitive PhotoMultiplier (Hamamatsu R2486-06) have been reproduced with high accuracy using the EGS4 code. Extensive simulation provides a detailed description of the performance of this type of detector as a function of the matrix granularity, the geometry of the detector and detection threshold. We present the Monte Carlo simulation and the preliminary experimental results of a prototype planar imaging system made of two matrices, each one consisting of 400 (2 x 2 x 30 mm 3 ) crystals of YAP-Ce

  9. Preliminary result and upgrade from WISPDMX Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Le Hoang; Horns, Dieter [Institut fur Experimentalphysik, Universitat Hamburg (Germany); Lobanov, Andrei [Institut fur Experimentalphysik, Universitat Hamburg (Germany); Max-Planck-Institut fur Radioastronomie, Bonn (Germany)

    2016-07-01

    The microwave cavity experiment WISPDMX is the first direct WISP (Weakly interactive slim particles) dark matter search experiment probing the particle masses in the 0.8-2.0 eV range. The first stage of WISPDMX measurements has been completed at nominal resonant frequencies of the cavity. The upgrading of the data acquisition and analysing has been done to increase the sensitivity of the experiment. We report preliminary result from the cavity tuning at second stage of WISPDMX.

  10. Percutaneous Irreversible Electroporation Lung Ablation: Preliminary Results in a Porcine Model

    International Nuclear Information System (INIS)

    Deodhar, Ajita; Monette, Sébastien; Single, Gordon W.; Hamilton, William C.; Thornton, Raymond H.; Sofocleous, Constantinos T.; Maybody, Majid; Solomon, Stephen B.

    2011-01-01

    Objective: Irreversible electroporation (IRE) uses direct electrical pulses to create permanent “pores” in cell membranes to cause cell death. In contrast to conventional modalities, IRE has a nonthermal mechanism of action. Our objective was to study the histopathological and imaging features of IRE in normal swine lung. Materials and Methods: Eleven female swine were studied for hyperacute (8 h), acute (24 h), subacute (96 h), and chronic (3 week) effects of IRE ablation in lung. Paired unipolar IRE applicators were placed under computed tomography (CT) guidance. Some applicators were deliberately positioned near bronchovascular structures. IRE pulse delivery was synchronized with the cardiac rhythm only when ablation was performed within 2 cm of the heart. Contrast-enhanced CT scan was performed immediately before and after IRE and at 1 and 3 weeks after IRE ablation. Representative tissue was stained with hematoxylin and eosin for histopathology. Results: Twenty-five ablations were created: ten hyperacute, four acute, and three subacute ablations showed alveolar edema and necrosis with necrosis of bronchial, bronchiolar, and vascular epithelium. Bronchovascular architecture was maintained. Chronic ablations showed bronchiolitis obliterans and alveolar interstitial fibrosis. Immediate post-procedure CT images showed linear or patchy density along the applicator tract. At 1 week, there was consolidation that resolved partially or completely by 3 weeks. Pneumothorax requiring chest tube developed in two animals; no significant cardiac arrhythmias were noted. Conclusion: Our preliminary porcine study demonstrates the nonthermal and extracellular matrix sparing mechanism of action of IRE. IRE is a potential alternative to thermal ablative modalities.

  11. Use of Diffusion Spectrum imaging in preliminary longitudinal evaluation of Amyotrophic Lateral Sclerosis: development of an imaging biomarker

    Directory of Open Access Journals (Sweden)

    Kumar eAbhinav

    2014-04-01

    Full Text Available Previous diffusion tensor imaging (DTI studies have shown white matter pathology in ALS, predominantly in the motor pathways. Further these studies have shown that DTI can be used longitudinally to track pathology over time, making white matter pathology a candidate as an outcome measure in future trials. DTI has demonstrated application in group studies, however its derived indices, for example fractional anisotropy, are susceptible to partial volume effects, making its role questionable in examining individual progression. We hypothesize that changes in the white matter are present in ALS beyond the motor tracts, and that the affected pathways and associated pattern of disease progression can be tracked longitudinally using automated diffusion connectometry analysis. Connectometry analysis is based on diffusion spectrum imaging (DSI and overcomes the limitations of a conventional tractography approach and DTI. The identified affected white matter tracts can then be assessed in a targeted fashion using High definition fiber tractography (a novel white matter MR imaging technique. Changes in quantitative and qualitative markers over time could then be correlated with clinical progression.We illustrate these principles towards developing an imaging biomarker for demonstrating individual progression, by presenting results for five ALS patients, including with longitudinal data in two. Preliminary analysis demonstrated a number of changes bilaterally and asymmetrically in motoric and extramotoric white matter pathways. Further the limbic system was also affected possibly explaining the cognitive symptoms in ALS. In the two longitudinal subjects, the white matter changes were less extensive at baseline, although there was evidence of disease progression in a frontal pattern with a relatively spared postcentral gyrus, consistent with the known pathology in ALS.

  12. 1ST-TRIMESTER SCREENING FOR FETAL CHROMOSOMAL-ABNORMALITIES - PRELIMINARY-RESULTS

    NARCIS (Netherlands)

    VANLITH, JMM

    We have started a multicentre trial to study the possibilities of first-trimester maternal serum screening for fetal chromosomal abnormalities. Maternal blood samples were obtained before 13 weeks of gestation. We present the preliminary results of the first 950 patients on alpha-fetoprotein (AFP).

  13. Preliminary results of neutron production in Sahand plasma focus device

    International Nuclear Information System (INIS)

    Siahpoush, V.; Mohammadi, M.A.; Khorram, S.; Shabani, I.; Borhanian, J.; Ashrafi, S.; Naghshara, H.; Moslehi-Fard, M.; Sobhanian, S.

    2004-01-01

    We report in this paper the preliminary results of neutron generation during fusion reaction in deuterium in the Sahand Filipov type plasma focus, recently installed and put in operation at Tabriz University. The special calibration procedure for neutron detection system, using activation method is described

  14. Value of magnetic resonance imaging in the radiotherapy planning of tumours of the uterine cervix: preliminary results

    International Nuclear Information System (INIS)

    Justino, Pitagoras Baskara; Carvalho, Heloisa de Andrade; Baroni, Ronaldo Hueb; Blasbalg, Roberto; Leite, Claudia da Costa

    2005-01-01

    Objective: To assess the rate of geographic miss on conventional radiotherapy planning of patients with cervical cancer, using magnetic resonance imaging. Materials and methods: Thirty-two patients with squamous cell carcinoma of the uterine cervix were studied. Magnetic resonance imaging of the pelvis was performed after clinical staging. Magnetic resonance imaging findings were compared with the classic fields described for the 'box' technique. Target volume within less than 1 cm margins of the fields' limits was considered as geographic miss. Results: Classical radiation field limits were inadequate in 24 cases (75%), all in the anterior (46%) or posterior (40%) border of the lateral fields. Conclusion: Magnetic resonance detected a high probability of geographic miss on conventional radiotherapy planning in this population, both in initial and advanced stages of the disease. (author)

  15. Preliminary Results of the Louisiana Sex Offender Treatment Program

    Directory of Open Access Journals (Sweden)

    Lee A. Underwood

    2015-12-01

    Full Text Available The purpose of this study was to offer preliminary support for the Louisiana Sex Offender Treatment Program (LSOTP in addressing the needs of juvenile sex offenders. Research objectives were (1 to offer statistical evidence for reductions in anxiety, depression, cognitive distortion and negative attitudes towards women comparing a group of 21 adolescents, 12 of whom received services as usual and nine of whom participated in the LSOTP. A controlled experimental evaluation design was utilized. The juvenile sex offenders were randomly assigned to the experimental group for 12 weeks receiving treatment services and a control group receiving care “as usual” in a residential group care program. Participants in the experimental group experienced statistically significant decreases in cognitive distortions related specifically to rape and molestation.The results of this study offer preliminary support of the LSOTP as a best practices alternative to other treatment modalities.

  16. Preliminary results of the aerosol optical depth retrieval in Johor, Malaysia

    International Nuclear Information System (INIS)

    Lim, H Q; Lau, A M S; Kanniah, K D

    2014-01-01

    Monitoring of atmospheric aerosols over the urban area is important as tremendous amounts of pollutants are released by industrial activities and heavy traffic flow. Air quality monitoring by satellite observation provides better spatial coverage, however, detailed aerosol properties retrieval remains a challenge. This is due to the limitation of aerosol retrieval algorithm on high reflectance (bright surface) areas. The aim of this study is to retrieve aerosol optical depth over urban areas of Iskandar Malaysia; the main southern development zone in Johor state, using Moderate Resolution Imaging Spectroradiometer (MODIS) 500 m resolution data. One of the important steps is the aerosol optical depth retrieval is to characterise different types of aerosols in the study area. This information will be used to construct a Look Up Table containing the simulated aerosol reflectance and corresponding aerosol optical depth. Thus, in this study we have characterised different aerosol types in the study area using Aerosol Robotic Network (AERONET) data. These data were processed using cluster analysis and the preliminary results show that the area is consisting of coastal urban (65%), polluted urban (27.5%), dust particles (6%) and heavy pollution (1.5%) aerosols

  17. Gold nanoparticles : A novel application of spectral imaging in proteomics - preliminary results

    NARCIS (Netherlands)

    Dietrich, H.R.C.; Young, I.T.; Garini, Y.

    2005-01-01

    The intense research in proteomics is demanding for fast, reliable and easy-to-use methods in order to study the proteome. In this proceeding we report the development of such a novel research tool based on spectral imaging and Resonance Light Scattering gold particles. This method will allow the

  18. Preliminary Results from Initial Investigations of Ceres' Cratering Record from Dawn Imaging Data

    Science.gov (United States)

    Schmedemann, Nico; Michael, Gregory; Ivanov, Boris A.; Kneissl, Thomas; Neesemann, Adrian; Hiesinger, Harald; Jaumann, Ralf; Raymond, Carol A.; Russell, Christopher T.

    2015-04-01

    The highly successful Dawn mission [1] finished data collection at Vesta in 2012 and is now on its way to the dwarf planet Ceres. According to the current Ceres approach timeline of the Dawn mission, the ground resolution of the Dawn FC camera [2] will be about 10 times better than Hubble data [3] at the time of the presentation of this work. This may allow for identification of craters about 15 km in diameter. Initial mapping of sample areas may provide enough information of the cratering record in order to compare it with the theoretical Ceres crater production function we present at the 46th LPSC conference (March 16-20, 2015, The Woodlands, Texas) [4]. Our preliminary crater production function for Ceres is derived from the assumption of an icy crust just below a thin surface layer of dust [5], and a projectile population that is very similar to the one that impacted the Moon [6]. In order to scale the lunar cratering record to Ceres we use the Ivanov scaling laws [7], which allow for crater scaling based on parameters that can be derived from observations. The lunar-like approach gave reasonable good results for the crater production function on the asteroids Vesta, Ida, Lutetia and Gaspra [8]. Since the lunar surface is of basaltic composition, the correct scaling between the different materials is challenging. One crucial parameter is the transition diameter from simple to complex craters. Based on the simple to complex transition diameter on Iapetus, an icy satellite of Saturn, we expect this transition at about 12 km crater size at Ceres. This value may be slightly different due to the different temperatures at Ceres and Iapetus. If the simple to complex transition is observed at much larger diameters, the reason could be a substantial fraction of rock in the shallow subsurface of Ceres. In an ice-rich surface material high relaxation rates may also be expected that could change the shape of the crater production function. A thorough geological mapping

  19. Trade-off results and preliminary designs of Near-Term Hybrid Vehicles

    Science.gov (United States)

    Sandberg, J. J.

    1980-01-01

    Phase I of the Near-Term Hybrid Vehicle Program involved the development of preliminary designs of electric/heat engine hybrid passenger vehicles. The preliminary designs were developed on the basis of mission analysis, performance specification, and design trade-off studies conducted independently by four contractors. THe resulting designs involve parallel hybrid (heat engine/electric) propulsion systems with significant variation in component selection, power train layout, and control strategy. Each of the four designs is projected by its developer as having the potential to substitute electrical energy for 40% to 70% of the petroleum fuel consumed annually by its conventional counterpart.

  20. New method of scoliosis assessment: preliminary results using computerized photogrammetry.

    Science.gov (United States)

    Aroeira, Rozilene Maria Cota; Leal, Jefferson Soares; de Melo Pertence, Antônio Eustáquio

    2011-09-01

    A new method for nonradiographic evaluation of scoliosis was independently compared with the Cobb radiographic method, for the quantification of scoliotic curvature. To develop a protocol for computerized photogrammetry, as a nonradiographic method, for the quantification of scoliosis, and to mathematically relate this proposed method with the Cobb radiographic method. Repeated exposure to radiation of children can be harmful to their health. Nevertheless, no nonradiographic method until now proposed has gained popularity as a routine method for evaluation, mainly due to a low correspondence to the Cobb radiographic method. Patients undergoing standing posteroanterior full-length spine radiographs, who were willing to participate in this study, were submitted to dorsal digital photography in the orthostatic position with special surface markers over the spinous process, specifically the vertebrae C7 to L5. The radiographic and photographic images were sent separately for independent analysis to two examiners, trained in quantification of scoliosis for the types of images received. The scoliosis curvature angles obtained through computerized photogrammetry (the new method) were compared to those obtained through the Cobb radiographic method. Sixteen individuals were evaluated (14 female and 2 male). All presented idiopathic scoliosis, and were between 21.4 ± 6.1 years of age; 52.9 ± 5.8 kg in weight; 1.63 ± 0.05 m in height, with a body mass index of 19.8 ± 0.2. There was no statistically significant difference between the scoliosis angle measurements obtained in the comparative analysis of both methods, and a mathematical relationship was formulated between both methods. The preliminary results presented demonstrate equivalence between the two methods. More studies are needed to firmly assess the potential of this new method as a coadjuvant tool in the routine following of scoliosis treatment.

  1. Preliminary test results for post irradiation examination on the HTTR fuel

    International Nuclear Information System (INIS)

    Ueta, Shohei; Umeda, Masayuki; Sawa, Kazuhiro; Sozawa, Shizuo; Shimizu, Michio; Ishigaki, Yoshinobu; Obata, Hiroyuki

    2007-01-01

    The future post-irradiation program for the first-loading fuel of the HTTR is scheduled using the HTTR fuel handling facilities and the Hot Laboratory in the Japan Materials Testing Reactor (JMTR) to confirm its irradiation resistance and to obtain data on its irradiation characteristics in the core. This report describes the preliminary test results and the future plan for a post-irradiation examination for the HTTR fuel. In the preliminary test, fuel compacts made with the same SiC-coated fuel particle as the first loading fuel were used. In the preliminary test, dimension, weight, fuel failure fraction, and burnup were measured, and X-ray radiograph, SEM, and EPMA observations were carried out. Finally, it was confirmed that the first-loading fuel of the HTTR showed good quality under an irradiation condition. The future plan for the post-irradiation tests was described to confirm its irradiation performance and to obtain data on its irradiation characteristics in the HTTR core. (author)

  2. Preliminary results of an oilspill risk analysis for the Bombay High Region

    Digital Repository Service at National Institute of Oceanography (India)

    Mascarenhas, A.A.M.Q.; Gouveia, A.D.; Sitaraman, R.

    oil were analysed, covering estimates of the time between spill occurrence and contact with resources. The combined results yielded estimates of the overall risks associated with production within the developmental area. Preliminary results...

  3. Some Preliminary Scientific Results of Chang'E-3 Mission

    Science.gov (United States)

    Zou, Y.; Li, W.; Zheng, Y.; Li, H.

    2015-12-01

    Chang'E-3 mission is the main task of Phase two of China Lunar Exploration Program (CLEP), and also is Chinese first probe of landing, working and roving on the moon. Chang'E-3 craft composed of a lander and a rover, and each of them carry four scientific payloads respectively. The landing site of Chang'E-3 was located at 44.12 degrees north latitude and 19.51 degrees west longitude, where is in the northern part of Imbrium Which the distance in its west direction from the landing site of former Soviet probe Luna-17 is about 400 km, and about 780km far from the landing site of Appolo-17 in its southeast direction. Unfortunately, after a series of scientific tests and exploration on the surface of the moon, the motor controller communication of the rover emerged a breakdown on January 16, 2014, which leaded the four payloads onboard the rover can't obtain data anymore. However, we have received some interesting scientific data which have been studied by Chinese scientists. During the landing process of Chang'E-3, the Landing camera got total 4673 images with the Resolution in millimeters to meters, and the lander and rover took pictures for each other at different point with Topography camera and Panoramic camera. We can find characteristic changes in celestial brightness with time by analyzing image data from Lunar-based Ultraviolet Telescope (LUT) and an unprecedented constraint on water content in the sunlit lunar exosphere seen by LUT). The figure observed by EUV camera (EUVC) shows that there is a transient weak area of the Earth's plasma sphere; This event took place about three hours. The scientists think that it might be related to the change of the particle density of mid-latitude ionosphere. The preliminary spectral and mineralogical results from the landing site are derived according to the data of Visible and Near-infrared Imaging Spectrometer (VNIS). Seven major elements including Mg, Al, Si, K, Ca, Ti and Fe have been identified by the Active Particle

  4. Preliminary Results on Uncertainty Quantification for Pattern Analytics

    Energy Technology Data Exchange (ETDEWEB)

    Stracuzzi, David John [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Brost, Randolph [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Chen, Maximillian Gene [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Malinas, Rebecca [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Peterson, Matthew Gregor [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Phillips, Cynthia A. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Robinson, David G. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Woodbridge, Diane [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    This report summarizes preliminary research into uncertainty quantification for pattern ana- lytics within the context of the Pattern Analytics to Support High-Performance Exploitation and Reasoning (PANTHER) project. The primary focus of PANTHER was to make large quantities of remote sensing data searchable by analysts. The work described in this re- port adds nuance to both the initial data preparation steps and the search process. Search queries are transformed from does the specified pattern exist in the data? to how certain is the system that the returned results match the query? We show example results for both data processing and search, and discuss a number of possible improvements for each.

  5. A preliminary investigation: the impact of microscopic condenser on depth of field in cytogenetic imaging

    Science.gov (United States)

    Ren, Liqiang; Qiu, Yuchen; Li, Zheng; Li, Yuhua; Zheng, Bin; Li, Shibo; Chen, Wei R.; Liu, Hong

    2013-02-01

    As one of the important components of optical microscopes, the condenser has a considerable impact on system performance, especially on the depth of field (DOF). DOF is a critical technical feature in cytogenetic imaging that may affect the efficiency and accuracy of clinical diagnosis. The purpose of this study is to investigate the influence of microscopic condenser on DOF using a prototype of transmitted optical microscope, based on objective and subjective evaluations. After the description of the relationship between condenser and objective lens and the theoretical analysis of the condenser impact on system numerical aperture and DOF, a standard resolution pattern and several cytogenetic samples are adopted to assess the condenser impact on DOF, respectively. The experimental results of these objective and subjective evaluations are in agreement with the theoretical analysis and show that, under the specific intermediate range of condenser numerical aperture ( NAcond ), the DOF value decreases with the increase of NAcond . Although the above qualitative results are obtained under the experimental conditions with a specific prototype system, the methods presented in this preliminary investigation could offer useful guidelines for optimizing operational parameters in cytogenetic imaging.

  6. Diffusion-Weighted Magnetic Resonance Imaging of Urinary Epithelial Cancer with Upper Urinary Tract Obstruction: Preliminary Results

    International Nuclear Information System (INIS)

    Takeuchi, M.; Matsuzaki, K.; Kubo, H.; Nishitani, H.

    2008-01-01

    Background: Various malignant tumors of the body show high signal intensity on diffusion-weighted magnetic resonance imaging (DWI). In the genitourinary region, DWI is expected to have a role in detecting urinary epithelial cancer noninvasively. Purpose: To demonstrate the feasibility of DWI for the diagnosis of urinary epithelial cancer with upper urinary tract obstruction. Material and Methods: Twenty upper urinary tract cancers in 16 patients were evaluated by high-b-value DWI (b=800s/mm2). The signal intensity was visually evaluated, and the apparent diffusion coefficients (ADCs) were measured. Results: All urinary epithelial cancers showed high signal intensity on DWI. The ADC in cancerous lesions was 1.31±0.27 x 10 -3 mm 2 /s, which was significantly lower than that of the lumens of the ureter or renal pelvis (3.32±0.44 x 10 -3 mm 2 /s; P<0.001). Maximum intensity projection images of DWI in combination with static-fluid MR urography provided three-dimensional entire urinary tract imaging with the extension of tumors. Conclusion: DWI is useful in the tumor detection and in evaluating the tumor extension of urinary epithelial cancer in patients with upper urinary tract obstruction

  7. Authentication by Keystroke Timing: Some Preliminary Results

    National Research Council Canada - National Science Library

    Gaines, R. S; Lisowski, William; Press, S. J; Shapiro, Norman

    1980-01-01

    ... of an individual seeking access to the computer. This report summarizes preliminary efforts to establish whether an individual can be identified by the statistical characteristics of his or her typing...

  8. Preliminary results of endorectal surface coil magnetic resonance imaging for local staging of prostate cancer

    International Nuclear Information System (INIS)

    Jager, G.H.; Barentsz, J.O.; Rosette, J.J.M.C.H. de la; Rosenbusch, G.

    1994-01-01

    Objective: To evaluate the effectiveness of endorectal surface coil (ERC) magnetic resonance imaging (MRI) in the local staging of adenocarcinoma of the prostate (ACP). Materials and methods: A total of 23 patients who were considered candidates for radical prostatectomy because of clinically localized ACP were examined by ERC-MRI. All patients underwent laparoscopic or open lymph-node dissection prior to surgery. Four patients had positive lymph nodes at operation. A total of 19 underwant radical prostatectomy, allowing comparison of the MRI data with the surgical pathologic findings. Results: Twelve patients had extraglandular spread of ACP (T3) and 7 had locally confined ACP (T2). ERC-MRI predicted correctly a T3 tumor in 10 of 12 cases and a T2 tumor in 4 of 7 cases. ERC-MRI was 74% accurate in differentiating T2 from T3 tumor. Three cases of overestimation were in studies with poor image quality because of bowel movement motion artifacts. Conclusion: ERC-MRI was found to be a sensitive modality in staging clinically localized ACP. (orig.) [de

  9. Preliminary Langmuir probe results on the CTX gun experiment

    International Nuclear Information System (INIS)

    Tuszewski, M.

    1981-12-01

    Preliminary results obtained with a double Langmuir probe in the Compact Toroid experiment facility confirm the existence of a gun plasma of n approx. 5 x 10 14 cm -3 and T approx. 10 eV lasting for approx. 250 to 400 μs, which is consistent with interferometry and Thomson scattering data. The probe current characteristics as a function of voltage suggest non-Maxwellian features of the particles distribution functions

  10. Preliminary results of Digital Pulse Shape Acquisition from Chimera

    International Nuclear Information System (INIS)

    Alderighi, D.M.; Sechi, G.; Anzalone, A.; Cavallaro, S.; Giustolisi, F.; Laguidara, E.; Lanzalone, G.; Porto, F.; Bassini, R.; Boiano, C.; Guazzoni, P.; Russo, S.; Sassi, M.; Zetta, L.; Cardella, G.; Defilippo, S.E.; Lanzano, G.; Paganod, A.; Papa, M.; Pirrone, S.; Politi, G.; Geraci, E.

    2003-01-01

    A 100 MS/s 14-bit Sampling Analog-to-Digital converter has been used to perform digital pulse-shape acquisition of signals collected from CHIMERA telescopes. The signals from a typical CHIMERA detection cell have been collected using both a standard CHIMERA electronic chain up to the amplifier, and a very simple analog front end, basically reduced to the preamplifier. The preliminary on-beam results are presented. (authors)

  11. Preliminary results of Digital Pulse Shape Acquisition from Chimera

    Energy Technology Data Exchange (ETDEWEB)

    Alderighi, D.M.; Sechi, G. [INFN Milano and IASF, CNR, Milano (France); Anzalone, A.; Cavallaro, S.; Giustolisi, F.; Laguidara, E.; Lanzalone, G.; Porto, F. [Catania Univ., LNS and Dipartimento di Fisica (France); Bassini, R.; Boiano, C.; Guazzoni, P.; Russo, S.; Sassi, M.; Zetta, L. [Milano Univ., INFN and Dipartimento di Fisica (Italy); Cardella, G.; Defilippo, S.E.; Lanzano, G.; Paganod, A.; Papa, M.; Pirrone, S.; Politi, G. [Catania Univ., INFN and Dipartimento di Fisica (Italy); Geraci, E. [Bologna Univ., INFN and Dipartimento di Fisica (Italy)

    2003-07-01

    A 100 MS/s 14-bit Sampling Analog-to-Digital converter has been used to perform digital pulse-shape acquisition of signals collected from CHIMERA telescopes. The signals from a typical CHIMERA detection cell have been collected using both a standard CHIMERA electronic chain up to the amplifier, and a very simple analog front end, basically reduced to the preamplifier. The preliminary on-beam results are presented. (authors)

  12. Hellenic Amateur Astronomy Association's activities: Preliminary results on Perseids 2010

    Science.gov (United States)

    Maravelias, G.

    2011-01-01

    Preliminary results on the Perseids 2010 are presented. Visual and video observations were obtained by the author and a first reduction of the visual data shows that a maximum of ZHR ~120 was reached during the night 12-13 of August 2010. Moreover, a video setup was tested (DMK camera and UFO Capture v2) and the results show that, under some limitations, valuable data can be obtained.

  13. Functional requirements regarding medical registries--preliminary results.

    Science.gov (United States)

    Oberbichler, Stefan; Hörbst, Alexander

    2013-01-01

    The term medical registry is used to reference tools and processes to support clinical or epidemiologic research or provide a data basis for decisions regarding health care policies. In spite of this wide range of applications the term registry and the functional requirements which a registry should support are not clearly defined. This work presents preliminary results of a literature review to discover functional requirements which form a registry. To extract these requirements a set of peer reviewed articles was collected. These set of articles was screened by using methods from qualitative research. Up to now most discovered functional requirements focus on data quality (e. g. prevent transcription error by conducting automatic domain checks).

  14. 13N-NH3 PET dynamic imaging in the diagnosis of hypopituitarism: preliminary result

    International Nuclear Information System (INIS)

    Zhang Xiangsong; He Zuoxiang; Tang Anwu; Qiao Suixian

    2004-01-01

    Objective: To evaluate the feasibility of diagnosing hypopituitarism with 13N-NH3 PET dynamic imaging. Methods: Eight volunteers (2 male, 6 female, age from 23 to 53 years old) for control and 7 patients (6 female, 20-42 years old, 1 male, 21 year old) were enrolled in this study. 13N-NH3 PET dynamic imaging was performed under 3-D acquisition on the ECAT HR+ PET scanner (Siemens/CTI) with 5-minute transmission scan. The emission protocol was a 20-minute dynamic scan (10s x 12, 30s x 6, 900s x 1) triggered simultaneously with a bolus injection of 444 to 592 MBq of 13N-NH3. The radioactivity - time curves of pituitary and internal carotid artery were generated by setting regions of interest (ROIs) on the transaxial planes of the frames of 13N-NH3 PET sequences. The first-pass uptake rate of 13N-NH3 (R) and standard uptake, rate (SUV) in pituitary on the last frame were calculated. Results: In control studies, the radioactivity in pituitary demonstrated within 10 seconds after the internal carotid artery showed up, and the pituitary highly uptake 13N-NH3, the size of pituitary was (1.07±0.17) cm x (1.09±0.15) cm x (1.14 ± 0.17) cm, SUV was 3.84 ± 1.75, R was 0.75 ± 0.13. In hypopituitarism studies, the radioactivity in pituitary showed up slowly, the pituitary did not show up in two cases with serious hypopituitarism, the size of pituitary was (0.82±0.07) cm x (0.81±0.05) cm x(0.91±0.07) cm, SUV was 1.25±0.08, R was 0.35±0.09. Conclusion: 13N-NH3 PET dynamic imaging is valuable in the diagnosis of hypopituitarism. (authors)

  15. Preliminary results of local earthquake tomography around Bali, Lombok, and Sumbawa regions

    Energy Technology Data Exchange (ETDEWEB)

    Nugraha, Andri Dian, E-mail: nugraha@gf.itb.ac.id; Puspito, Nanang T; Yudistira, Tedi [Global Geophysical Reserach Group, Faculty of Mining and Petroleum Engineering, Institute of Technology Bandung, JlGanesa 10, Bandung, 40132 (Indonesia); Kusnandar, Ridwan; Sakti, Artadi Pria [Meteorological, Climatological, and Geophysical Agency (MCGA) of Indonesian, Jakarta (Indonesia)

    2015-04-24

    Bali, Sumbawa, and Lombok regions are located in active tectonic influence by Indo-Australia plate subducts beneath Sunda plate in southern part and local back-arc thrust in northern part the region. Some active volcanoes also lie from eastern part of Java, Bali, Lombok and Sumbawa regions. Previous studies have conducted subsurface seismic velocity imaging using regional and global earthquake data around the region. In this study, we used P-arrival time from local earthquake networks compiled by MCGA, Indonesia within time periods of 2009 up to 2013 to determine seismic velocity structure and simultaneously hypocenter adjustment by applying seismic tomography inversion method. For the tomographic inversion procedure, we started from 1-D initial velocity structure. We evaluated the resolution of tomography inversion results through checkerboard test and calculating derivative weigh sum. The preliminary results of tomography inversion show fairly clearly high seismic velocity subducting Indo-Australian and low velocity anomaly around volcano regions. The relocated hypocenters seem to cluster around the local fault system such as back-arc thrust fault in northern part of the region and around local fault in Sumbawa regions. Our local earthquake tomography results demonstrated consistent with previous studies and improved the resolution. For future works, we will determine S-wave velocity structure using S-wave arrival time to enhance our understanding of geological processes and for much better interpretation.

  16. Preliminary results of a test of a longitudinal phase-space monitor

    International Nuclear Information System (INIS)

    Kikutani, Eiji; Funakoshi, Yoshihiro; Kawamoto, Takashi; Mimashi, Toshihiro

    1994-01-01

    A prototype of a longitudinal phase-space monitor has been developed in TRISTAN Main Ring at KEK. The principle of the monitor and its basic components are explained. Also a result of a preliminary beam test is given. (author)

  17. Preliminary Results on Asymptotic Stabilization of Hamiltonian Systems with Nonholonomic Constraints

    NARCIS (Netherlands)

    Khennouf, H.; Canudas de Wit, C.; Schaft, A.J. van der

    1995-01-01

    This paper presents some preliminary results on asymptotic stabilization of nonholonomic mechanical systems using the Hamiltonian formulation proposed previously. Our work seeks to establish a general formulation for designing time-varying controllers for some mechanical system described in the

  18. A preliminary diffusional kurtosis imaging study of Parkinson disease: comparison with conventional diffusion tensor imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kamagata, Koji; Kamiya, Kouhei; Suzuki, Michimasa; Hori, Masaaki; Yoshida, Mariko; Aoki, Shigeki [Juntendo University School of Medicine, Department of Radiology, Bunkyo-ku, Tokyo (Japan); Tomiyama, Hiroyuki; Hatano, Taku; Motoi, Yumiko; Hattori, Nobutaka [Juntendo University School of Medicine, Department of Neurology, Tokyo (Japan); Abe, Osamu [Nihon University School of Medicine, Department of Radiology, Tokyo (Japan); Shimoji, Keigo [National Center of Neurology and Psychiatry Hospital, Department of Radiology, Tokyo (Japan)

    2014-03-15

    Diffusional kurtosis imaging (DKI) is a more sensitive technique than conventional diffusion tensor imaging (DTI) for assessing tissue microstructure. In particular, it quantifies the microstructural integrity of white matter, even in the presence of crossing fibers. The aim of this preliminary study was to compare how DKI and DTI show white matter alterations in Parkinson disease (PD). DKI scans were obtained with a 3-T magnetic resonance imager from 12 patients with PD and 10 healthy controls matched by age and sex. Tract-based spatial statistics were used to compare the mean kurtosis (MK), mean diffusivity (MD), and fractional anisotropy (FA) maps of the PD patient group and the control group. In addition, a region-of-interest analysis was performed for the area of the posterior corona radiata and superior longitudinal fasciculus (SLF) fiber crossing. FA values in the frontal white matter were significantly lower in PD patients than in healthy controls. Reductions in MK occurred more extensively throughout the brain: in addition to frontal white matter, MK was lower in the parietal, occipital, and right temporal white matter. The MK value of the area of the posterior corona radiata and SLF fiber crossing was also lower in the PD group. DKI detects changes in the cerebral white matter of PD patients more sensitively than conventional DTI. In addition, DKI is useful for evaluating crossing fibers. By providing a sensitive index of brain pathology in PD, DKI may enable improved monitoring of disease progression. (orig.)

  19. Preliminary Results Of A 600 Joules Small Plasma Focus Device

    International Nuclear Information System (INIS)

    Lee, S. H.; Yap, S. L.; Wong, C. S.

    2009-01-01

    Preliminary results of a 600 J (3.7 μF, 18 kV) Mather type plasma focus device operated at low pressure will be presented. The discharge is formed between a solid anode with length of 6 cm and six symmetrically and coaxially arranged cathode rods of same lengths. The cathode base is profiled in a knife-edge design and a set of coaxial plasma gun are attached to it in order to initiate the breakdown and enhance the current sheath formation. The experiments have been performed in argon gas under a low pressure condition of several microbars. The discharge current and the voltage across the electrodes during the discharge are measured with high voltage probe and current coil. The current and voltage characteristics are used to determine the possible range of operating pressure that gives good focusing action. At a narrow pressure regime of 9.0±0.5 μbar, focusing action is observed with good reproducibility. Preliminary result of ion beam energy is presented. More work will be carried out to investigate the radiation output.

  20. Breast tomography with synchrotron radiation: preliminary results

    International Nuclear Information System (INIS)

    Pani, Silvia; Longo, Renata; Dreossi, Diego; Montanari, Francesco; Olivo, Alessandro; Arfelli, Fulvia; Bergamaschi, Anna; Poropat, Paolo; Rigon, Luigi; Zanconati, Fabrizio; Palma, Ludovico Dalla; Castelli, Edoardo

    2004-01-01

    A system for in vivo breast imaging with monochromatic x-rays has been designed and built at the synchrotron radiation facility Elettra in Trieste (Italy) and will be operational in 2004. The system design involves the possibility of performing both planar mammography and breast tomography. In the present work, the first results obtained with a test set-up for breast tomography are shown and discussed. Tomographic images of in vitro breasts were acquired using monochromatic x-ray beams in the energy range 20-28 keV and a linear array silicon pixel detector. Tomograms were reconstructed using standard filtered backprojection algorithms; the effect of different filters was evaluated. The attenuation coefficients of fibroglandular and adipose tissue were measured, and a quantitative comparison of images acquired at different energies was performed by calculating the differential signal-to-noise ratio of fibroglandular details in adipose tissue. All images required a dose comparable to the dose delivered in clinical, conventional mammography and showed a high resolution of the breast structures without the overlapping effects that limit the visibility of the structures in 2D mammography. A quantitative evaluation of the images proves that the image quality at a given dose increases in the considered energy range and for the considered breast sizes

  1. 77 FR 72817 - Glycine From the People's Republic of China: Preliminary Results of Antidumping Duty...

    Science.gov (United States)

    2012-12-06

    ... Republic of China: Preliminary Results of Antidumping Duty Administrative Review and Preliminary Partial... conducting an administrative review of the antidumping duty order on glycine from the People's Republic of... covers one exporter of subject merchandise, Baoding Mantong Fine Chemistry Co. Ltd. (Baoding Mantong). We...

  2. Flat-panel detector volumetric CT for visualization of subarachnoid hemorrhage and ventricles: preliminary results compared to conventional CT

    International Nuclear Information System (INIS)

    Doelken, M.; Struffert, T.; Richter, G.; Engelhorn, T.; Doerfler, A.; Nimsky, C.; Ganslandt, O.; Hammen, T.

    2008-01-01

    The aim of this study was to compare flat-panel volumetric CT (VCT) to conventional CT (cCT) in the visualization of the extent of subarachnoid hemorrhage (SAH) and the width of the ventricles in patients with acute SAH. Included in the study were 22 patients with an acutely ruptured cerebral aneurysm who received VCT during coil embolization. VCT image quality, the extent of SAH (using a modified Fisher score and total slice number with SAH visible) and the width of the ventricles (Evans index) were evaluated by two experienced neuroradiologists (RAD1 and RAD2) and compared to the findings on cCT. Ten patients undergoing VCT for reasons other than SAH served as negative controls. Interobserver agreement in rating image quality was excellent for cCT (Kendall W value 0.94) and good for VCT (0.74). SAH was identified by RAD1 and RAD2 on VCT images in all patients. The modified Fisher scores underestimated the extent of SAH on VCT images in comparison with cCT images. Pearson's correlation coefficient (r) regarding the number of image slices with SAH visible on cCT images compared with the number on VCT images was 0.85 for RAD1 and 0.84 for RAD2. The r value for the degree of interobserver agreement for the number of slices with SAH visible was 0.99 for cCT, and 0.95 for VCT images (n 19), respectively. The width of the ventricles measured in terms of the Evans Index showed excellent concordance between the modalities (r = 0.81 vs. 0.82). Our preliminary results indicate that VCT is helpful in evaluating SAH in the angiography suite. Additionally, reliable evaluation of ventricle width is feasible. However, there are limitations with regard to the visibility of SAH on VCT images in comparison to cCT images. (orig.)

  3. Preliminary results of the round-robin testing of F82H

    Energy Technology Data Exchange (ETDEWEB)

    Shiba, K.; Yamanouchi, N.; Tohyama, A.

    1996-10-01

    Preliminary results of metallurgical, physical and mechanical properties of low activation ferritic steel F82H (IEA heat) were obtained in the round-robin test in Japan. The properties of IEA heat F82H were almost the same as the original F82H.

  4. Radon concentrations in Norwegian kindergartens: survey planning and preliminary results

    International Nuclear Information System (INIS)

    Birovljev, A.; Strand, T.; Heiberg, A.

    1998-01-01

    An extensive radon survey in Norwegian kindergartens and schools was started in early 1997; so far 2481 kindergartens were examined. Preliminary results of the first phase of the survey are presented in tabular and graphic form including, among others, the dependence of average radon concentration on the construction year of the kindergartens and on the age of the buildings. (A.K.)

  5. PRELIMINARY RESULTS OF ESTIMATING SOIL MOISTURE OVER BARE SOIL USING FULL-POLARIMETRIC ALOS-2 DATA

    Directory of Open Access Journals (Sweden)

    A. Sekertekin

    2016-10-01

    Full Text Available Synthetic Aperture Radar (SAR imaging system is one of the most effective way for Earth observation. The aim of this study is to present the preliminary results about estimating soil moisture using L-band Synthetic Aperture Radar (SAR data. Full-polarimetric (HH, HV, VV, VH ALOS-2 data, acquired on 22.04.2016 with the incidence angle of 30.4o, were used in the study. Simultaneously with the SAR acquisition, in-situ soil moisture samples over bare agricultural lands were collected and evaluated using gravimetric method. Backscattering coefficients for all polarizations were obtained and linear regression analysis was carried out with in situ moisture measurements. The best correlation coefficient was observed with VV polarization. Cross-polarized backscattering coefficients were not so sensitive to soil moisture content. In the study, it was observed that soil moisture maps can be retrieved with the accuracy about 14% (RMSE.

  6. Intraarterial Ultrasound in Pancreatic Cancer: Feasibility Study and Preliminary Results

    International Nuclear Information System (INIS)

    Larena-Avellaneda, Axel; Timm, Stephan; Kickuth, Ralph; Kenn, Werner; Steger, Ulrich; Jurowich, Christian; Germer, Christoph-Thomas

    2010-01-01

    Despite technological advances in computed tomography (CT) and magnetic resonance imaging, the involvement of the celiac or mesenteric artery in pancreatic cancer remains uncertain in many cases. Infiltration of these vessels is important in making decisions about therapy choices but often can only be definitively determined through laparotomy. Local (intraarterial) ultrasound may increase diagnostic accuracy. Using the Volcano intravascular ultrasound (IVUS) system, we applied a transfemoral method to scan the celiac and mesenteric arteries directly intraarterial. This technique was used in five patients with suspected pancreatic cancer. Technical success was achieved in all cases. In one case, a short dissection of the mesenteric artery occurred but could be managed interventionally. In tumors that did not contact with the vessels, IVUS was unable to display the tissue pathology. Our main interest was the infiltration of the arteries. In one case, infiltration was certain in the CT scan but uncertain in two patients. In the latter two cases, IVUS correctly predicted infiltration in one and freedom from tumor in the other case. In our preliminary study, IVUS correctly predicted arterial infiltration in all cases. IVUS did not provide new information when the tumor was far away from the vessel. Compared with IVUS in the portal vein, the information about the artery is more detailed, and the vessel approach is easier. These results encouraged us to design a prospective study to evaluate the sensitivity and specificity of this method.

  7. The Southern HII Region Discovery Survey: Preliminary Results

    Science.gov (United States)

    Shea, Jeanine; Wenger, Trey; Balser, Dana S.; Anderson, Loren D.; Armentrout, William P.; Bania, Thomas M.; Dawson, Joanne; Miller Dickey, John; Jordan, Christopher; McClure-Griffiths, Naomi M.

    2017-01-01

    HII regions are some of the brightest sources at radio frequencies in the Milky Way and are the sites of massive O and B-type star formation. They have relatively short (Bank Telescope. Candidate HII regions were selected from mid-infrared emission coincident with radio continuum emission, and confirmed as HII regions by the detection of radio recombination lines. Here we discuss the Southern HII Region Discovery Survey (SHRDS), a continuation of the HRDS using the Australia Telescope Compact Array over the Galactic longitude range 230 to 360 degrees. We have reduced and analyzed a small sub-set of the SHRDS sources and discuss preliminary results, including kinematic distances and metallicities.

  8. Development and Reliability of a Preliminary Foot Osteoarthritis Magnetic Resonance Imaging Score.

    Science.gov (United States)

    Halstead, Jill; Martín-Hervás, Carmen; Hensor, Elizabeth M A; McGonagle, Dennis; Keenan, Anne-Maree; Redmond, Anthony C; Conaghan, Philip G

    2017-08-01

    Foot osteoarthritis (OA) is very common but underinvestigated musculoskeletal condition and there is little consensus as to common magnetic resonance imaging (MRI) features. The aim of this study was to develop a preliminary foot OA MRI score (FOAMRIS) and evaluate its reliability. This preliminary semiquantitative score included the hindfoot, midfoot, and metatarsophalangeal joints. Joints were scored for joint space narrowing (JSN; 0-3), osteophytes (0-3), joint effusion/synovitis, and bone cysts (present/absent). Erosions and bone marrow lesions (BML) were scored (0-3) and BML were evaluated adjacent to entheses and at sub-tendon sites (present/absent). Additionally, tenosynovitis (0-3) and midfoot ligament pathology (present/absent) were scored. Reliability was evaluated in 15 people with foot pain and MRI-detected OA using 3.0T MRI multi-sequence protocols, and assessed using ICC as an overall score and per anatomical site. Intrareader agreement (ICC) was generally good to excellent across the foot in joint features (JSN 0.90, osteophytes 0.90, effusion/synovitis 0.46, cysts 0.87), bone features (BML 0.83, erosion 0.66, BML entheses 0.66, BML sub-tendon 0.60) and soft tissue features (tenosynovitis 0.83, ligaments 0.77). Interreader agreement was lower for joint features (JSN 0.43, osteophytes 0.27, effusion/synovitis 0.02, cysts 0.48), bone features (BML 0.68, erosion 0.00, BML entheses 0.34, BML sub-tendon 0.13), and soft tissue features (tenosynovitis 0.35, ligaments 0.33). This preliminary FOAMRIS demonstrated good intrareader reliability and fair interreader reliability when assessing the total feature scores. Further development is required in cohorts with a range of pathologies and to assess the psychometric measurement properties.

  9. Musculoskeletal infection imaging using 99Tcm-ciprofloxacin: preliminary observations

    International Nuclear Information System (INIS)

    Choong, K.K.L.; Kumar, V.; Gruenewald, S.M.; Larcos, G.; Farlow, D.C.

    1999-01-01

    Full text: Clinically available infection imaging techniques employing labelled leukocytes (WBC) and gallium citrate are sensitive for inflammation but often lack specificity for infection. 99 Tc m -ciprofloxacin (CIPRO), a labelled broad-spectrum antibiotic, is potentially more specific for infection. We present the CIPRO findings from 13 pts (8 M; 5 F; mean age 58 years) referred with possible current musculoskeletal sepsis. WBC were performed in 10 pts and temporally preceded CIPRO in 7. The average time between scans was 3 days. Eleven of the 13 pts had a prior history of documented infection secondary to trauma or joint surgery. All received antibiotics at some stage prior to CIPRO with 10 on antibiotics at the time of the scan. Final diagnosis of infection (diagnosed in 7 pts) was based on microbiological results from swabs and surgical specimens (7 pts) or the clinical course over the subsequent months (6 pts). CIPRO correctly identified 10/13 pts (77%) as having infection or no infection compared to 6/10 (60%) using WBC (P = N.S.). CIPRO and WBC were concordant in 7/10 pts. Discordant results were due to 1 false-positive CIPRO, 2 false-positive WBC. Scan accuracy in both groups may be affected by the inclusion of a patient with an equivocal diagnosis of infection; and the timing of the scans. Our preliminary observations are: (1) CIPRO is a promising diagnostic agent for musculoskeletal sepsis deserving further evaluation. (2) CIPRO appears at least as accurate as WBC but with significant preparation advantages. (3) Optimal CIPRO scanning time yet to be determined but should be at least 3-4 h post-injection to lessen blood pool effect

  10. The microcirculation image quality score: development and preliminary evaluation of a proposed approach to grading quality of image acquisition for bedside videomicroscopy.

    Science.gov (United States)

    Massey, Michael J; Larochelle, Ethan; Najarro, Gabriel; Karmacharla, Adarsh; Arnold, Ryan; Trzeciak, Stephen; Angus, Derek C; Shapiro, Nathan I

    2013-12-01

    Side-stream dark-field microscopy is currently used to directly visualize sublingual microcirculation at the bedside. Our experience has found inherent technical challenges in the image acquisition process. This article presents and assesses a quality assurance method to rate image acquisition quality before analysis. We identified 6 common image capture and analysis problem areas in sublingual side-stream dark-field videos: illumination, duration, focus, content, stability, and pressure. We created the "Microcirculation Image Quality Score" by assigning a score of optimal (0 points), suboptimal but acceptable (1 point), or unacceptable (10 points) to each category (for further details, go to http://www.MicroscanAnalysis.blogspot.com). We evaluated 59 videos from a convenience sample of 34 unselected, noncritically ill emergency department patients to create a test set. Two raters, blinded to each other, implemented the score. Any video with a cumulative score of 10 or higher (range, 0-60) was considered unacceptable for further analysis. We created the Microcirculation Image Quality Score and applied it to 59 videos. For this particular set of 59 videos, the mean (SD) passing quality score was 1.68 (0.90), and the mean (SD) failing quality score was 15.74 (6.19), with 27 of 59 passing the quality score less than 10. Highest failure occurred from pressure artifact. The interrater agreement for acceptability was assessed using Cohen κ for each category: illumination (κ = 1.0), duration (κ = 1.0), focus (κ = 0.91), content (κ = 0.76), stability (κ = 0.71), and pressure (κ = 0.82) and overall pass-fail rates (score >10) (κ = 0.66). Our Microcirculation Image Quality Score addresses many of the common areas where video quality can degrade. The criteria introduced are an objective way to assess the quality of image acquisition, with the goal of selecting videos of adequate quality for analysis. The interrater reliability results in our preliminary study suggest

  11. Diffusion tensor imaging and fiber tractography in cervical compressive myelopathy: preliminary results

    International Nuclear Information System (INIS)

    Lee, Joon Woo; Kim, Jae Hyoung; Park, Jong Bin; Lee, Guen Young; Kang, Heung Sik; Park, Kun Woo; Yeom, Jin S.

    2011-01-01

    To assess diffusion tensor imaging (DTI) parameters in cervical compressive myelopathy (CCM) patients compared to normal volunteers, to relate them with myelopathy severity, and to relate tractography patterns with postoperative neurologic improvement. Twenty patients suffering from CCM were prospectively enrolled (M:F = 13:7, mean age, 49.6 years; range 22-67 years) from September 2009 to March 2010. Sensitivity encoding (SENSE) single-shot echo-planar imaging (EPI) was used for the sagittal DTI. Twenty sex- and age-matched normal volunteers underwent the same scanning procedure. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values in the spinal cord were compared between the patients and normal volunteers and were related to myelopathy severity based on Japanese Orthopedic Association (JOA) scores. Tractography patterns were related to myelopathy severity and postoperative improvement. There were significant differences between patients and normal volunteers in terms of FA (0.498 ± 0.114 vs. 0.604 ± 0.057; p = 0.001) and ADC (1.442 ± 0.389 vs. 1.169 ± 0.098; p = 0.001). DTI parameters and tractography patterns were not related to myelopathy severity. In ten patients in the neurologically worse group, postoperative neurologic improvement was seen in four of five patients with intact fiber tracts, but only one of five patients with interrupted fiber tracts exhibited neurologic improvement. DTI parameters in CCM patients were significantly different from those in normal volunteers but were not significantly related to myelopathy severity. The patterns of tractography appear to correlate with postoperative neurologic improvement. (orig.)

  12. Nb/NiCu bilayers in single and stacked superconductive tunnel junctions: preliminary results

    International Nuclear Information System (INIS)

    Pepe, G.P.; Ruotolo, A.; Parlato, L.; Peluso, G.; Ausanio, G.; Carapella, G.; Latempa, R.

    2004-01-01

    We present preliminary experimental results concerning both single and stacked tunnel junctions in which one of the electrodes was formed by a superconductor/ferromagnet (S/F) bi-layer. In particular, in the stacked configuration a Nb/NiCu bi-layer was used as the intermediate electrode, and it was probed by tunneling on both sides. Tunnel junctions have been characterized in terms of current-voltage characteristics (IVC), and differential conductance. Preliminary steady-state injection-detection measurements performed in the stacked devices at T=4.2 K are also presented and discussed

  13. Ultrasonic propulsion of kidney stones: preliminary results of human feasibility study.

    Science.gov (United States)

    Bailey, Michael; Cunitz, Bryan; Dunmire, Barbrina; Paun, Marla; Lee, Franklin; Ross, Susan; Lingeman, James; Coburn, Michael; Wessells, Hunter; Sorensen, Mathew; Harper, Jonathan

    2014-09-03

    One in 11 Americans has experienced kidney stones, with a 50% average recurrence rate within 5-10 years. Ultrasonic propulsion (UP) offers a potential method to expel small stones or residual fragments before they become a recurrent problem. Reported here are preliminary findings from the first investigational use of UP in humans. The device uses a Verasonics ultrasound engine and Philips HDI C5-2 probe to generate real-time B-mode imaging and targeted "push" pulses on demand. There are three arms of the study: de novo stones, post-lithotripsy fragments, and the preoperative setting. A pain questionnaire is completed prior to and following the study. Movement is classified based on extent. Patients are followed for 90 days. Ten subjects have been treated to date: three de novo , five post-lithotripsy, and two preoperative. None of the subjects reported pain associated with the treatment or a treatment related adverse event, beyond the normal discomfort of passing a stone. At least one stone was moved in all subjects. Three of five post-lithotripsy subjects passed a single or multiple stones within 1-2 weeks following treatment; one subject passed two (1-2 mm) fragments before leaving clinic. In the pre-operative studies we successfully moved 7 - 8 mm stones. In four subjects, UP revealed multiple stone fragments where the clinical image and initial ultrasound examination indicated a single large stone.

  14. Long range radio tracking of sea turtles and polar bear: Instrumentation and preliminary results

    Science.gov (United States)

    Baldwin, H. A.

    1972-01-01

    Instrumentation developed for studies of path behavior of the green sea turtle and migration movement of polar bear is described. Preliminary results bearing on navigation ability in these species are presented. Both species operate in difficult environments, and the problems faced in the design of electronic instrumentation for these studies are not completely specified at this time. However, the critical factors yet to be understood are primarily related to the behavior of instrumented animals. The data obtained with these experimental techniques are included, first to illustrate the technique and, second to provide initial preliminary results bearing on animal navigation.

  15. Integrated remote sensing techniques for the detection of buried archaeological adobe structures: preliminary results in Cahuachi (Peru)

    Science.gov (United States)

    Masini, N.; Rizzo, E.; Lasaponara, R.; Orefici, G.

    2008-11-01

    This paper is focused on the jointly use of satellite Quickbird (QB) images and Ground Probing Radar (GPR) for assessing their capability in the detection of archaeological adobe structures (sun-dried earth material). Such detection is particularly complex. due to the low contrast generally existing between the archaeological features and the background. Two significant test areas were investigated in the Ceremonial Centre of Cahuachi (in the Nasca territory, Southern Peru) dating back to 6th century BC to 4th century AD. Our results showed that both satellite and GPR data provided valuable indications for unearthing precious ancient remains. Our preliminary analyses pointed out that the integrated use of non destructive remote sensing techniques has high potentiality for its important scientific implications and for its significant contributions to cultural resource management.

  16. Validation of model-based brain shift correction in neurosurgery via intraoperative magnetic resonance imaging: preliminary results

    Science.gov (United States)

    Luo, Ma; Frisken, Sarah F.; Weis, Jared A.; Clements, Logan W.; Unadkat, Prashin; Thompson, Reid C.; Golby, Alexandra J.; Miga, Michael I.

    2017-03-01

    The quality of brain tumor resection surgery is dependent on the spatial agreement between preoperative image and intraoperative anatomy. However, brain shift compromises the aforementioned alignment. Currently, the clinical standard to monitor brain shift is intraoperative magnetic resonance (iMR). While iMR provides better understanding of brain shift, its cost and encumbrance is a consideration for medical centers. Hence, we are developing a model-based method that can be a complementary technology to address brain shift in standard resections, with resource-intensive cases as referrals for iMR facilities. Our strategy constructs a deformation `atlas' containing potential deformation solutions derived from a biomechanical model that account for variables such as cerebrospinal fluid drainage and mannitol effects. Volumetric deformation is estimated with an inverse approach that determines the optimal combinatory `atlas' solution fit to best match measured surface deformation. Accordingly, preoperative image is updated based on the computed deformation field. This study is the latest development to validate our methodology with iMR. Briefly, preoperative and intraoperative MR images of 2 patients were acquired. Homologous surface points were selected on preoperative and intraoperative scans as measurement of surface deformation and used to drive the inverse problem. To assess the model accuracy, subsurface shift of targets between preoperative and intraoperative states was measured and compared to model prediction. Considering subsurface shift above 3 mm, the proposed strategy provides an average shift correction of 59% across 2 cases. While further improvements in both the model and ability to validate with iMR are desired, the results reported are encouraging.

  17. Sedimentation on the Valencia Continental Shelf: Preliminary results

    Science.gov (United States)

    Maldonado, Andres; Swift, Donald J. P.; Young, Robert A.; Han, Gregory; Nittrouer, Charles A.; DeMaster, David J.; Rey, Jorge; Palomo, Carlos; Acosta, Juan; Ballester, A.; Castellvi, J.

    1983-10-01

    Preliminary analysis of data collected during the course of a cooperative Spanish-United States investigation of the Valencia Shelf (western Mediterranean) reveals a storm-dominated, mud-accumulating sedimentary regime. Calcareous mud is accumulating seaward of a narrow band of shoreface sand and gravel. On the outer shelf the mud is enriched by a pelagic calcareous component. Preliminary 210Pb data from vertical profiles of box cores yield nominal accumulation rates from 2.6 mm y -1 near the Ebro Delta to 1.3 mm y -1 on the southern portion of the Valencia Shelf. Storm-current winnowing has resulted in the development of a biogenic lag sand over the mid-shelf mud in the northern part of the study area. Piston cores reveal a basal Holocene sand and gravel facies similar to that presently seen on the inner shelf. Upward-fining sequences on the central and outer shelf are inferred to result from the landward shift of lithotopes during the course of the Holocene transgression. These sequences are locally repeated, perhaps as the consequence of brief, local interludes of coastal progradation. Application of a diagnostic circulation model suggests that intense, downwelling coastal flows occur during winter northeastern storms. Storm activity has induced erosional shoreface retreat during the course of the Holocene transgression and has generated by this means the basal coarse facies observed in the piston cores. In the central part of the study area seaward of the Albufera Lagoon, the mud blanket thins to a layer several centimeters thick which is draped over a thickened (10 m) basal sand. The basal sand is molded into northwest trending ridges. The data are not sufficient to determine whether these are overstepped barriers, or submarine sand ridges formed by storm flows during the shoreface retreat process.

  18. Selective CT mesentericography in the diagnostics of obscure overt intestinal bleeding: preliminary results

    International Nuclear Information System (INIS)

    Schuermann, K.; Buecker, A.; Tacke, J.; Schmitz-Rode, T.; Guenther, R.W.; Jansen, M.

    2002-01-01

    Aim: To evaluate intra-arterial CT mesentericography (CTM) in the diagnostics of severe obscure overt intestinal bleeding in comparison with conventional mesentericography (MG) and surgery. Methods: In 8 patients (23 - 82 years, mean 59 years), CTM was performed via the catheter left in the superior mesenteric artery after MG to detect the source of bleeding. Early and late-phase spiral CT scans were acquired after administration of contrast medium. Active bleeding was considered to be present if extravasation of contrast medium into the bowel was found. The results of MG and CTM were compared with the results of surgery. Results: With MG active bleeding was found in one patient, with CTM in five patients. In three patients, both MG and CTM were negative. Six patients underwent surgery. Five cases of bleeding detected with CTM were confirmed by surgery. In one case, bleeding found with CTM was not confirmed by surgery. One patient underwent surgery although all imaging procedures were negative. The source of bleeding remained unknown. Surgically, the site of bleeding was located in the jejunum in 3 patients (jejunitis, jejunal ulcers, carcinoid), one patient had a diverticulum in the ascending colon. The colonic bleeding site was correctly localized with CTM, whereas the small bowel bleeding could only roughly be assigned to the proximal or distal jejunum or jejunoileal transition area. Conclusion: Preliminary results indicate that selective CTM is superior to MG in the evaluation of severe obscure overt intestinal bleeding. (orig.) [de

  19. Fractal Analysis of Elastographic Images for Automatic Detection of Diffuse Diseases of Salivary Glands: Preliminary Results

    Directory of Open Access Journals (Sweden)

    Alexandru Florin Badea

    2013-01-01

    Full Text Available The geometry of some medical images of tissues, obtained by elastography and ultrasonography, is characterized in terms of complexity parameters such as the fractal dimension (FD. It is well known that in any image there are very subtle details that are not easily detectable by the human eye. However, in many cases like medical imaging diagnosis, these details are very important since they might contain some hidden information about the possible existence of certain pathological lesions like tissue degeneration, inflammation, or tumors. Therefore, an automatic method of analysis could be an expedient tool for physicians to give a faultless diagnosis. The fractal analysis is of great importance in relation to a quantitative evaluation of “real-time” elastography, a procedure considered to be operator dependent in the current clinical practice. Mathematical analysis reveals significant discrepancies among normal and pathological image patterns. The main objective of our work is to demonstrate the clinical utility of this procedure on an ultrasound image corresponding to a submandibular diffuse pathology.

  20. Doses in pediatric patients undergoing chest and abdomen CT examinations. Preliminary results

    International Nuclear Information System (INIS)

    Jornada, Tiago S.; Silva, Teogenes A. da

    2011-01-01

    Computed tomography (CT) is a non-invasive method of image production that imparts significant doses to a patient, it is expected that pediatric CT examinations will increase the risk of induced cancer in children. In this study the effective doses in a five year-old child submitted to chest or abdomen CT scans were assessed for comparison purposes. The CTEXPO computed program was used with data from routine protocols of a 0 to 13 year-old children in two public hospitals in Belo Horizonte. Hospital A used a Siemens Dual-Slice unit with 80 kV, 41 mA and pitch 2 for chest or abdomen; hospital B used a Multislice GE unit with 120 kV, 45 mA and pitch 1 for chest and 120 kV, 55 mA. and pitch 1 for abdomen. Results of effective doses in a five year-old child were 1.7 and 1.0 mSv in hospital A and 9.1 and 7.2 mSv in hospital B, for chest and abdomen, respectively. Results were compared to the reference effective doses of 7.2 and 5.0 mSv for chest and abdomen respectively that were derived from the air kerma length product values given in ICRP publication 87. Results of hospital A showed that low dose exposures also can be achieved in CT scans of children. Results showed that even a hospital with a modern facility (hospital B) can provided doses higher than reference values if protocols are not adjusted for children. Preliminary results suggested that there is a room for optimizing children exposure submitted to CT scans. (author)

  1. Image compression of bone images

    International Nuclear Information System (INIS)

    Hayrapetian, A.; Kangarloo, H.; Chan, K.K.; Ho, B.; Huang, H.K.

    1989-01-01

    This paper reports a receiver operating characteristic (ROC) experiment conducted to compare the diagnostic performance of a compressed bone image with the original. The compression was done on custom hardware that implements an algorithm based on full-frame cosine transform. The compression ratio in this study is approximately 10:1, which was decided after a pilot experiment. The image set consisted of 45 hand images, including normal images and images containing osteomalacia and osteitis fibrosa. Each image was digitized with a laser film scanner to 2,048 x 2,048 x 8 bits. Six observers, all board-certified radiologists, participated in the experiment. For each ROC session, an independent ROC curve was constructed and the area under that curve calculated. The image set was randomized for each session, as was the order for viewing the original and reconstructed images. Analysis of variance was used to analyze the data and derive statistically significant results. The preliminary results indicate that the diagnostic quality of the reconstructed image is comparable to that of the original image

  2. Oil Spill Detection and Modelling: Preliminary Results for the Cercal Accident

    Science.gov (United States)

    da Costa, R. T.; Azevedo, A.; da Silva, J. C. B.; Oliveira, A.

    2013-03-01

    two-dimensional surface plume transport model VOILS [1] with the oil spreading formulation enabled. The remaining oil weathering processes (evaporation, emulsification, dispersion and dissolution in the water column) and shoreline retention were disregarded. The computational structure of the model is based on Eulerian-Lagrangian formulations, horizontal unstructured mesh discretization and it is soft-coupled with the tri-dimensional hydrodynamic model SELFE - Semi-Implicit Eulerian Lagrangian Finite Element [15] that uses hybrid sigma-Z coordinates in the vertical. The preliminary results of this hindcast simulation for the Cercal oil spill are presented and compared with available satellite SAR images. The forcings used play an important role in the final results. During the late stage spreading phases of the oil, about one month after the spill, the Douro River outflow is best seen in the SAR images. The morphology of the river outflow is discussed according to traditional coastal dynamics, and compared with model results. In addition to several interesting physical features that were identified, we report on the generation of Internal Solitary Waves (ISW) in the vicinity of the Douro River Plume (DRP). It is well known that trains of short-period internal waves can be generated by river plumes (such as the Columbia River). The internal structure of the observed internal waves (elevation waves or mode-2 versus mode-1 internal waves) is discussed based on the SAR signatures and available stratification. The present work has been conducted under an FCT - Fundaç ão para a Ciência e a Tecnologia / MCTES - Ministério da Ciência, Tecnologia e Ensino Superior (PIDDAC - Programa de Investimentos e Despesas de Desenvolvimento da Administraç ão Central) Portuguese funded project entitled PAC:MAN Pollution accidents in coastal areas: a Risk management system (PTDC/AACAMB/113469/2008).

  3. National Data Center Preparedness Exercise 2015 (NPE 2015): MY-NDC Preliminary Analysis Result

    International Nuclear Information System (INIS)

    Faisal Izwan Abdul Rashid; Muhammed Zulfakar Zolkaffly

    2016-01-01

    Malaysia has established the CTBT National Data Centre (MY-NDC) in December 2005. MY-NDC is tasked to perform Comprehensive Nuclear-Test-Ban-Treaty (CTBT) data management as well as provide information for Treaty related events to Nuclear Malaysia as CTBT National Authority. In 2015, MY-NDC has participated in the National Data Centre Preparedness Exercise 2015 (NPE 2015). This paper aims at presenting MY-NDC preliminary analysis result of NPE 2015. In NPE 2015, MY-NDC has performed five different analyses, namely, radionuclide, atmospheric transport modelling (ATM), data fusion, seismic analysis and site forensics. The preliminary findings show the hypothetical scenario in NPE 2015 most probably is an uncontained event resulted high release of radionuclide to the air. (author)

  4. The value of 3D T1-weighted gradient-echo MR imaging for evaluation of the appendix during pregnancy: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Kyung Mi; Kim, Seong Hyun; Choi, Dongil; Lee, Soon Jin; Rhim, Hyunchul; Park, Min Jung (Depts. of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of)), email: kshyun@skku.edu

    2011-10-15

    Background The use of oral contrast has been essential for the identification of a normal appendix on MR imaging during pregnancy. However, stool could be used as a positive oral contrast as it is characterized by a relatively high signal on T1-weighted imaging, and 3D T1-weighted gradient-echo (T1W-GRE) MR imaging has been used to evaluate 3 mm diameter intestines in fetuses. Purpose To evaluate the added value of 3D T1W-GRE MR imaging in combination with T2-weighted imaging (T2WI) compared to T2WI alone for evaluating the appendix during pregnancy. Material and Methods Eighteen consecutive pregnant patients who were clinically suspected of having acute appendicitis underwent appendix MR imaging which included T2WI with or without spectral presaturation attenuated inversion-recovery (SPAIR) fat suppression, and 3D T1W-GRE with SPAIR fat suppression. Two radiologists reviewed the two image sets (the T2WI set and the combined set of T2WI and 3D T1W-GRE images). Pathologic and clinical results served as the reference standard. The differences in the degree of visibility of the appendix and confidence scale for diagnosing acute appendicitis between two image sets were compared by using the paired Wilcoxon signed rank test. Results For both reviewers, the degree of visibility of the appendix using the combined T2WI and 3D T1W-GRE images was significantly higher than using T2WI alone (P < 0.01), and the confidence levels for acute appendicitis using combined T2WI and 3D T1W-GRE images were significantly different from those using T2WI alone (P < 0.01). In the 13 patients with a normal appendix, both reviewers showed improved confidence levels for appendicitis using combined T2WI and 3D T1W-GRE images than T2WI alone. Conclusion Adding 3D T1W-GRE images to T2WI is helpful for identification of the appendix, as compared to T2WI alone in pregnant women without ingestion of oral contrast material. This may improve diagnostic confidence for acute appendicitis in pregnant

  5. Preliminary performance of image quality for a low-dose C-arm CT system with a flat-panel detector

    Energy Technology Data Exchange (ETDEWEB)

    Kyung Cha, Bo [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Seo, Chang-Woo [Department of Radiation Convergence Engineering, College of Health Science, Yonsei University, Wonju (Korea, Republic of); Yang, Keedong [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Jeon, Seongchae, E-mail: sarim@keri.re.kr [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Huh, Young [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of)

    2015-06-01

    Digital flat panel imager (FPI)-based cone-beam computed tomography (CBCT) has been widely used in C-arm imaging for spine surgery and interventional procedures. The system provides real-time fluoroscopy with high spatial resolution and three-dimensional (3D) visualization of anatomical structure without the need for patient transportation in interventional suite. In this work, a prototype CBCT imaging platform with continuous single rotation about the gantry was developed by using a large-area flat-panel detector with amorphous Si-based thin film transistor matrix. The different 2D projection images were acquired during constant gantry velocity for reconstructed images at a tube voltage of 80–120 kVp, and different current (10–50 mA) conditions. Various scan protocols were applied to a chest phantom human by changing the number of projection images and scanning angles. The projections were then reconstructed into a volumetric data of sections by using a 3D reconstruction algorithm (e.g., filtered back projection). The preliminary quantitative X-ray performance of our CBCT system was investigated by using the American Association of Physicists in Medicine CT phantom in terms of spatial resolution, contrast resolution, and CT number linearity for mobile or fixed C-arm based CBCT application with limited rotational geometry. The novel results of the projection data with different scanning angles and angular increments in the orbital gantry platform were acquired and evaluated experimentally.

  6. Preliminary performance of image quality for a low-dose C-arm CT system with a flat-panel detector

    International Nuclear Information System (INIS)

    Kyung Cha, Bo; Seo, Chang-Woo; Yang, Keedong; Jeon, Seongchae; Huh, Young

    2015-01-01

    Digital flat panel imager (FPI)-based cone-beam computed tomography (CBCT) has been widely used in C-arm imaging for spine surgery and interventional procedures. The system provides real-time fluoroscopy with high spatial resolution and three-dimensional (3D) visualization of anatomical structure without the need for patient transportation in interventional suite. In this work, a prototype CBCT imaging platform with continuous single rotation about the gantry was developed by using a large-area flat-panel detector with amorphous Si-based thin film transistor matrix. The different 2D projection images were acquired during constant gantry velocity for reconstructed images at a tube voltage of 80–120 kVp, and different current (10–50 mA) conditions. Various scan protocols were applied to a chest phantom human by changing the number of projection images and scanning angles. The projections were then reconstructed into a volumetric data of sections by using a 3D reconstruction algorithm (e.g., filtered back projection). The preliminary quantitative X-ray performance of our CBCT system was investigated by using the American Association of Physicists in Medicine CT phantom in terms of spatial resolution, contrast resolution, and CT number linearity for mobile or fixed C-arm based CBCT application with limited rotational geometry. The novel results of the projection data with different scanning angles and angular increments in the orbital gantry platform were acquired and evaluated experimentally

  7. A Simplified Approach to Measure the Effect of the Microvasculature in Diffusion-weighted MR Imaging Applied to Breast Tumors: Preliminary Results.

    Science.gov (United States)

    Teruel, Jose R; Goa, Pål E; Sjøbakk, Torill E; Østlie, Agnes; Fjøsne, Hans E; Bathen, Tone F

    2016-11-01

    Purpose To evaluate the relative change of the apparent diffusion coefficient (ADC) at low- and medium-b-value regimens as a surrogate marker of microcirculation, to study its correlation with dynamic contrast agent-enhanced (DCE) magnetic resonance (MR) imaging-derived parameters, and to assess its potential for differentiation between malignant and benign breast tumors. Materials and Methods Ethics approval and informed consent were obtained. From May 2013 to June 2015, 61 patients diagnosed with either malignant or benign breast tumors were prospectively recruited. All patients were scanned with a 3-T MR imager, including diffusion-weighted imaging (DWI) and DCE MR imaging. Parametric analysis of DWI and DCE MR imaging was performed, including a proposed marker, relative enhanced diffusivity (RED). Spearman correlation was calculated between DCE MR imaging and DWI parameters, and the potential of the different DWI-derived parameters for differentiation between malignant and benign breast tumors was analyzed by dividing the sample into equally sized training and test sets. Optimal cut-off values were determined with receiver operating characteristic curve analysis in the training set, which were then used to evaluate the independent test set. Results RED had a Spearman rank correlation of 0.61 with the initial area under the curve calculated from DCE MR imaging. Furthermore, RED differentiated cancers from benign tumors with an overall accuracy of 90% (27 of 30) on the test set with 88.2% (15 of 17) sensitivity and 92.3% (12 of 13) specificity. Conclusion This study presents promising results introducing a simplified approach to assess results from a DWI protocol sensitive to the intravoxel incoherent motion effect by using only three b values. This approach could potentially aid in the differentiation, characterization, and monitoring of breast pathologies. © RSNA, 2016 Online supplemental material is available for this article.

  8. TU-F-18A-01: Preliminary Results of a Prototype Quality Control Process for Spectral CT

    International Nuclear Information System (INIS)

    Nute, J; Jacobsen, M; Pennington, J; Cody, D; Chandler, A; Imai, Y; Baiu, C

    2014-01-01

    Purpose: A prototype quality control (QC) phantom and analysis process has been designed specifically to monitor dual-energy CT and address the current lack of quantitative oversight of the spectral capabilities of these scanners. Methods: A prototype solid water phantom was designed with multiple material inserts, and to support both head and body protocols. Inserts included tissue equivalent and material rods (iodine, iron, calcium) at various concentrations. The oval body phantom, measuring 30cm×40cm×15cm, was scanned using four dual-energy protocols with CTDIvol ranges of 19.6–62mGy (0.516 pitch) and 10.3–32.5mGy (0.984 pitch), and rotation times ranging from 0.5-1sec. The circular head phantom, measuring 22cm in diameter by 15cm, was scanned using three dual-energy protocols with CTDIvol ranges of 67–132.6mGy (0.531 pitch) and 36.7–72.7mGy (0.969 pitch), and rotation times ranging from 0.5–0.9sec. All images were reconstructed at 50, 70, 110 and 140 keV, and using a water-iodine material basis pair. The images were evaluated for iodine quantification accuracy and stability of monoenergetic reconstructions. The phantom was scanned twice on ten GE 750HD CT scanners to evaluate inter-scanner agreement, as well as ten times on a single scanner over a oneweek period to evaluate intra-scanner repeatability. Results: Preliminary analysis revealed consistent (inter- and intra-scanner) iodine quantification accuracy within 10% was only achieved for protocols in the upper half of dose levels assessed when grouped by pitch. Although all scanners undergo rigorous daily single-energy QC, iodine quantification accuracy from one scanner unexpectedly deviated from the other nine substantially. In general, inter-scanner agreement and intra-scanner repeatability varied with dose, rotation time and reconstructed keV. Conclusion: Preliminary results indicate the need for a dual-energy QC process to ensure inter-scanner agreement and intra-scanner repeatability. In

  9. Preliminary Results Of LOCA Problem For APR1400 Reactor

    International Nuclear Information System (INIS)

    Le Dai Dien; Hoang Minh Giang; Le Thi Thu; Vo Thi Huong; Le Van Hong

    2011-01-01

    Several features of NPP with APR1400 nuclear reactor during a loss of coolant accident (LOCA) are investigated in this study. The report describes some main design characteristics of an engineering safety systems of APR1400 and the thermal hydraulic calculation results for steady-state using MARS and RELAP/SCDAPSIM codes. Large Break LOCA accident has been analyzed and evaluated based on acceptable criteria for ECCS given by US NRC. The results from cold leg break LOCA with broken area of 0.0465 m 2 in case of high pressure safety injection system (HPSI) failed to operate or 2 and 4 HPSI pumps are activated. The preliminary results of this work is a part of collaboration between INST researchers and KAERI experts in using RELAP tool for safety analysis of NPPs. (author)

  10. Radiolabelling of RC-160: preliminary results

    International Nuclear Information System (INIS)

    Verdera, E.S.; Balter Binsky, H.S.; Robles, A.M.; Rodriguez, G.; Souto, B.; Laiz, J.; Oliver, P.; Leon, E.

    1998-01-01

    Vapreotide (RC-160) was labelled with 125 I using Chloramine-T and Iodogen methods and with 99m Tc by a direct method with sodium ditionite as reducing agent in the presence of ascorbic acid. Several methods of purification and quality control were evaluated. Yields of the reactions and of purification steps were calculated. The results obtained for the radioiodination reactions showed higher yields when limiting Chloramine-T method was used. Labelling of RC-160 with 99m Tc indicated better yields when high radioactivity concentration of the radionuclide was used. Stability of the products obtained was assessed at different post-labelling times by selected quality control methods: Sep-Pak cartridge as purification method and chromatography by RP-HPLC and ITLC-SG using saline solution as solvent. It was demonstrated that I-125-RC-160 and Tc-99m-RC-160 were stable during five weeks (at -20 deg. C) and 6 hours (at room temperature) respectively. Preliminary biodistribution of Tc-99m-RC-160 in normal rats and mice were done showing different biological behaviour compared with control animals injected with pertechnetate. In conclusion, RC-160 was successfully labelled with both radionuclides, with radiochemical purity higher than 95%. These results encourage further research work in animal models as well as to investigate the biochemical behaviour of radiolabelled peptide. (author)

  11. The roles of MR imaging in monitoring therapeutic effectiveness in rheumatoid arthritis: preliminary result

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Mi Jin; Suh, Jin Suck; Lee, Soo Kon; Lee, Ji Soo [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of); Cho, Jae Hyun [Ajou Univ. College of Medicine, Asan (Korea, Republic of)

    1996-07-01

    It is difficult to determine objectively therapeutic response in rheumatoid arthritis. This study was carried out in order to assess the feasibility of MR imaging to determine disease status following antirheumatoid medication. Eight patients with rheumatoid arthritis underwent MR studies before treatment and approximately one year after the beginning of antirheumatoid medication. Coronal images were obtained, using a T1- and T2-weighted spin echo(n=8), contrast-enhanced T1-weighted image(n=8) and dynamic contrast-enhanced image(n=4). Bone erosions, synovial hypertrophy and bone marrow enhancement in pre-and post-medication studies were compared. On dynamic study, enhancement ratio(E) of pannus was measured(E=SNR at 30sec/ SNR at precontrast). Changes of MRI findings and enhancement ratio between pre- and post-medication were compared with disease status as assessed by clinical index. In three patients, improvement of bone marrow edema and synovial hypertrophy was noted, and in addition, there was no evidence of newly developed bone erosion. In two of these patients, complete remission was noted on the basis of the ARA criteria. In another three patients, despite improvement of bone marrow edema and synovial hypertrophy and improved clinical parameters including morning stiffness and ESR, discrete and newly developed bone erosions were noted. In one patient with a poor response to antirheumatoid medication, aggravation of bone marrow edema and synovial hypertrophy was seen, but no definite change in bone erosions was noted. In the remaining one patient, no remarkable changes were seen in bone marrow edema, synovial hypertrophy or bone erosion. Clinically this patient showed no morning stiffness or elevated ESR. The enhancement ratio of pannus decreased in all 4 cases, especially where there were complete remission. Synovial extent, bone marrow enhancement, bone erosions and enhancement ratio of pannus may be good parameters for monitoring disease activity in the

  12. The roles of MR imaging in monitoring therapeutic effectiveness in rheumatoid arthritis: preliminary result

    International Nuclear Information System (INIS)

    Yun, Mi Jin; Suh, Jin Suck; Lee, Soo Kon; Lee, Ji Soo; Cho, Jae Hyun

    1996-01-01

    It is difficult to determine objectively therapeutic response in rheumatoid arthritis. This study was carried out in order to assess the feasibility of MR imaging to determine disease status following antirheumatoid medication. Eight patients with rheumatoid arthritis underwent MR studies before treatment and approximately one year after the beginning of antirheumatoid medication. Coronal images were obtained, using a T1- and T2-weighted spin echo(n=8), contrast-enhanced T1-weighted image(n=8) and dynamic contrast-enhanced image(n=4). Bone erosions, synovial hypertrophy and bone marrow enhancement in pre-and post-medication studies were compared. On dynamic study, enhancement ratio(E) of pannus was measured(E=SNR at 30sec/ SNR at precontrast). Changes of MRI findings and enhancement ratio between pre- and post-medication were compared with disease status as assessed by clinical index. In three patients, improvement of bone marrow edema and synovial hypertrophy was noted, and in addition, there was no evidence of newly developed bone erosion. In two of these patients, complete remission was noted on the basis of the ARA criteria. In another three patients, despite improvement of bone marrow edema and synovial hypertrophy and improved clinical parameters including morning stiffness and ESR, discrete and newly developed bone erosions were noted. In one patient with a poor response to antirheumatoid medication, aggravation of bone marrow edema and synovial hypertrophy was seen, but no definite change in bone erosions was noted. In the remaining one patient, no remarkable changes were seen in bone marrow edema, synovial hypertrophy or bone erosion. Clinically this patient showed no morning stiffness or elevated ESR. The enhancement ratio of pannus decreased in all 4 cases, especially where there were complete remission. Synovial extent, bone marrow enhancement, bone erosions and enhancement ratio of pannus may be good parameters for monitoring disease activity in the

  13. The 3D Reference Earth Model: Status and Preliminary Results

    Science.gov (United States)

    Moulik, P.; Lekic, V.; Romanowicz, B. A.

    2017-12-01

    In the 20th century, seismologists constructed models of how average physical properties (e.g. density, rigidity, compressibility, anisotropy) vary with depth in the Earth's interior. These one-dimensional (1D) reference Earth models (e.g. PREM) have proven indispensable in earthquake location, imaging of interior structure, understanding material properties under extreme conditions, and as a reference in other fields, such as particle physics and astronomy. Over the past three decades, new datasets motivated more sophisticated efforts that yielded models of how properties vary both laterally and with depth in the Earth's interior. Though these three-dimensional (3D) models exhibit compelling similarities at large scales, differences in the methodology, representation of structure, and dataset upon which they are based, have prevented the creation of 3D community reference models. As part of the REM-3D project, we are compiling and reconciling reference seismic datasets of body wave travel-time measurements, fundamental mode and overtone surface wave dispersion measurements, and normal mode frequencies and splitting functions. These reference datasets are being inverted for a long-wavelength, 3D reference Earth model that describes the robust long-wavelength features of mantle heterogeneity. As a community reference model with fully quantified uncertainties and tradeoffs and an associated publically available dataset, REM-3D will facilitate Earth imaging studies, earthquake characterization, inferences on temperature and composition in the deep interior, and be of improved utility to emerging scientific endeavors, such as neutrino geoscience. Here, we summarize progress made in the construction of the reference long period dataset and present a preliminary version of REM-3D in the upper-mantle. In order to determine the level of detail warranted for inclusion in REM-3D, we analyze the spectrum of discrepancies between models inverted with different subsets of the

  14. The Majorana Demonstrator Status and Preliminary Results

    Science.gov (United States)

    Yu, C.-H.; Alvis, S. I.; Arnquist, I. J.; Avignone, F. T.; Barabash, A. S.; Barton, C. J.; Bertrand, F. E.; Bode, T.; Brudanin, V.; Busch, M.; Buuck, M.; Caldwell, T. S.; Chan, Y.-D.; Christofferson, C. D.; Chu, P.-H.; Cuesta, C.; Detwiler, J. A.; Dunagan, C.; Efremenko, Yu; Ejiri, H.; Elliott, S. R.; Gilliss, T.; Giovanetti, G. K.; Green, M.; Gruszko, J.; Guinn, I. S.; Guiseppe, V. E.; Haufe, C. R.; Hehn, L.; Henning, R.; Hoppe, E. W.; Howe, M. A.; Keeter, K. J.; Kidd, M. F.; Konovalov, S. I.; Kouzes, R. T.; Lopez, A. M.; Martin, R. D.; Massarczyk, R.; Meijer, S. J.; Mertens, S.; Myslik, J.; Othman, G.; Pettus, W.; Poon, A. W. P.; Radford, D. C.; Rager, J.; Reine, A. L.; Rielage, K.; Ruof, N. W.; Shanks, B.; Shirchenko, M.; Suriano, A. M.; Tedeschi, D.; Varner, R. L.; Vasilyev, S.; Vetter, K.; Vorren, K.; White, B. R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Yumatov, V.; Zhitnikov, I.; Zhu, B. Z.

    2018-05-01

    The MAJORANA Collaboration is using an array of high-purity Ge detectors to search for neutrinoless double-beta decay in 76Ge. Searches for neutrinoless double-beta decay are understood to be the only viable experimental method for testing the Majorana nature of the neutrino. Observation of this decay would imply violation of lepton number, that neutrinos are Majorana in nature, and provide information on the neutrino mass. The MAJORANA DEMONSTRATOR comprises 44.1 kg of p-type point-contact Ge detectors (29.7 kg enriched in 76Ge) surrounded by a low-background shield system. The experiment achieved a high efficiency of converting raw Ge material to detectors and an unprecedented detector energy resolution of 2.5 keV FWHM at Qββ. The MAJORANA collaboration began taking physics data in 2016. This paper summarizes key construction aspects of the Demonstrator and shows preliminary results from initial data.

  15. Barkhausen Effect and Acoustic Emission in a Metallic Glass - Preliminary Results

    International Nuclear Information System (INIS)

    Lopez Sanchez, R.; Lopez Pumarega, M.I.; Armeite, M.; Piotrkowski, R.; Ruzzante, J.E.

    2004-01-01

    Magneto Acoustic Emission, which is Barkhausen Noise (BN) and Acoustic Emission (AE), depends on microstructure and existing residual stresses in magnetic materials. Preliminary results obtained by magnetization along two perpendicular directions on a metal glass foil are presented. Signals were analyzed with Statistic, Fast Fourier and Wavelet methods. Results are part of a Joint Research Project of the Faculty of Science, Cantabria University, Spain, and the Elastic Waves Group of the National Atomic Energy Commission, Argentina

  16. Modelled and Observed Diurnal SST Signals: "SSTDV:R.EX.-IM.A.M." Project Preliminary Results

    DEFF Research Database (Denmark)

    Karagali, Ioanna; Høyer, Jacob; LeBorgne, Pierre

    2013-01-01

    This study presents some of the preliminary results from the ESA Support To Science Element (STSE) funded project on the Diurnal Variability of the Sea Surface Temperature, regarding its Regional Extend and Implications in Atmospheric Modelling (SSTDV:R.EX.–IM.A.M.). During this phase of the proj......This study presents some of the preliminary results from the ESA Support To Science Element (STSE) funded project on the Diurnal Variability of the Sea Surface Temperature, regarding its Regional Extend and Implications in Atmospheric Modelling (SSTDV:R.EX.–IM.A.M.). During this phase...

  17. Preliminary results of the Spacelab 2 superfluid helium experiment

    International Nuclear Information System (INIS)

    Mason, P.V.; Collins, D.J.; Elleman, D.D.; Jackson, H.W.; Wang, T.

    1986-01-01

    An experiment to investigate the properties of superfluid helium in a microgravity environment flew on the Shuttle on the Spacelab 2 mission in July and August of 1985. This paper summarizes the flight experiment and describes some preliminary results. The experiment comprised an investigation of long-wavelength third-sound waves in micron-thick films, a study of the motions of superfluid helium under milli-g and micro-g accelerations, and measurements of the fluctuations in temperature associated with the small motions of the bulk helium. An additional objective was to qualify and characterize a reflyable, space-compatible cryostat

  18. Multifractionated image-guided and stereotactic intensity-modulated radiotherapy of paraspinal tumors: A preliminary report

    International Nuclear Information System (INIS)

    Yamada, Yoshiya; Lovelock, D. Michael; Yenice, Kamil M.; Bilsky, Mark H.; Hunt, Margaret A.; Zatcky, Joan; Leibel, Steven A.

    2005-01-01

    irradiated patients, respectively. More than 90% of patients experienced palliation from pain, weakness, or paresthesia; 75% and 81% of secondary and primary lesions, respectively, exhibited local control at the time of last follow-up. No cases of radiation-induced myelopathy or radiculopathy have thus far been encountered. Conclusions: Precision stereotactic and image-guided paraspinal IMRT allows the delivery of high doses of radiation in multiple fractions to tumors within close proximity to the spinal cord while respecting cord tolerance. Although preliminary, the clinical results are encouraging

  19. Preliminary experimental results of tungsten wire-array Z-pinches on primary test stand

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Xian-Bin; Zhou, Shao-Tong; Dan, Jia-Kun; Ren, Xiao-Dong, E-mail: amosrxd@163.com; Wang, Kun-Lun; Zhang, Si-Qun; Li, Jing; Xu, Qiang; Cai, Hong-Chun; Duan, Shu-Chao; Ouyang, Kai; Chen, Guang-Hua; Ji, Ce; Wei, Bing; Feng, Shu-Ping; Wang, Meng; Xie, Wei-Ping; Deng, Jian-Jun [Key Laboratory of Pulsed Power, Institute of Fluid Physics, China Academy of Engineering Physics, P.O. Box 919-108, Mianyang, Sichuan 621999 (China); Zhou, Xiu-Wen; Yang, Yi [Research Center of Laser Fusion, China Academy of Engineering Physics, P.O. Box 919-987, Mianyang, Sichuan 621999 (China)

    2015-07-15

    The Primary Test Stand (PTS) developed at the China Academy of Engineering Physics is a 20 TW pulsed power driver, which can deliver a ∼10 MA, 70 ns rise-time (10%–90%) current to a short-circuit load and has important applications in Z-pinch driven inertial confinement fusion and high energy density physics. Preliminary results of tungsten wire-array Z-pinch experiments on PTS are presented. The load geometries investigated include 15-mm-tall cylindrical single and nested arrays with diameter ranging from 13 mm to 30 mm, consisting of 132–300 tungsten wires with 5–10 μm in diameter. Multiple diagnostics were fielded to characterize the x-ray radiation from wire-array Z pinches. The x-ray peak power (∼50 TW) and total radiated energy (∼500 kJ) were obtained from a single 20-mm-diam array with 80-ns stagnation time. The highest x-ray peak power up to 80 TW with 2.4 ns FWHM was achieved by using a nested array with 20-mm outer diameter, and the total x-ray energy from the nested array is comparable to that of single array. Implosion velocity estimated from the time-resolved image measurement exceeds 30 cm/μs. The detailed experimental results and other findings are presented and discussed.

  20. Preliminary results of natural radioactivity measurements in the southern part of Ethiopia

    International Nuclear Information System (INIS)

    Wollel Tiruneh, Getachew; Wodaje Kebede, Worku

    2008-01-01

    The paper presents the first results of natural radioactivity measurements in the Southern part of Ethiopia (Bale Zone-Oromiya Regional State). The preliminary results indicate that radiation levels in the mining areas of Kallido Mountain are elevated compared with those in the town of Negele Borena (background area). Both external gamma radiation and alpha surface contamination levels are significantly elevated above local background levels

  1. Preliminary results of natural radioactivity measurements in the southern part of Ethiopia

    Energy Technology Data Exchange (ETDEWEB)

    Wollel Tiruneh, Getachew [Ethiopian Radiation Protection Authority, PO Box 20486 code 1000, Addis-Ababa (Ethiopia)], E-mail: gwollel@yahoo.com; Wodaje Kebede, Worku [Ethiopian Radiation Protection Authority, PO Box 20486 code 1000, Addis-Ababa (Ethiopia)

    2008-11-15

    The paper presents the first results of natural radioactivity measurements in the Southern part of Ethiopia (Bale Zone-Oromiya Regional State). The preliminary results indicate that radiation levels in the mining areas of Kallido Mountain are elevated compared with those in the town of Negele Borena (background area). Both external gamma radiation and alpha surface contamination levels are significantly elevated above local background levels.

  2. Hyperspectral imaging in medicine: image pre-processing problems and solutions in Matlab.

    Science.gov (United States)

    Koprowski, Robert

    2015-11-01

    The paper presents problems and solutions related to hyperspectral image pre-processing. New methods of preliminary image analysis are proposed. The paper shows problems occurring in Matlab when trying to analyse this type of images. Moreover, new methods are discussed which provide the source code in Matlab that can be used in practice without any licensing restrictions. The proposed application and sample result of hyperspectral image analysis. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Investigation of polarized-proton target materials by differential calorimetry: preliminary results

    International Nuclear Information System (INIS)

    Hill, D.A.; Hill, J.J.

    1980-01-01

    A simple differential calorimeter was designed and operated for an investigation of the thermodynamic properties of polarized target materials. The calibration and use of the calorimeter are discussed, after a brief exposition of our motivation for this work. The results of a preliminary study of target materials is presented with emphasis on the relevance of the glass state to dynamic polarization in chemically-doped targets

  4. Facial emotional recognition in schizophrenia: preliminary results of the virtual reality program for facial emotional recognition

    Directory of Open Access Journals (Sweden)

    Teresa Souto

    2013-01-01

    Full Text Available BACKGROUND: Significant deficits in emotional recognition and social perception characterize patients with schizophrenia and have direct negative impact both in inter-personal relationships and in social functioning. Virtual reality, as a methodological resource, might have a high potential for assessment and training skills in people suffering from mental illness. OBJECTIVES: To present preliminary results of a facial emotional recognition assessment designed for patients with schizophrenia, using 3D avatars and virtual reality. METHODS: Presentation of 3D avatars which reproduce images developed with the FaceGen® software and integrated in a three-dimensional virtual environment. Each avatar was presented to a group of 12 patients with schizophrenia and a reference group of 12 subjects without psychiatric pathology. RESULTS: The results show that the facial emotions of happiness and anger are better recognized by both groups and that the major difficulties arise in fear and disgust recognition. Frontal alpha electroencephalography variations were found during the presentation of anger and disgust stimuli among patients with schizophrenia. DISCUSSION: The developed program evaluation module can be of surplus value both for patient and therapist, providing the task execution in a non anxiogenic environment, however similar to the actual experience.

  5. Response of lead-acid batteries to chopper-controlled discharge: Preliminary results

    Science.gov (United States)

    Cataldo, R. L.

    1978-01-01

    The preliminary results of simulated electric vehicle, chopper, speed controller discharge of a battery show energy output losses up to 25 percent compared to constant current discharges at the same average discharge current of 100 amperes. These energy losses are manifested as temperature rises during discharge, amounting to a two-fold increase for a 400-ampere pulse compared to the constant current case. Because of the potentially large energy inefficiency, the results suggest that electric vehicle battery/speed controller interaction must be carefully considered in vehicle design.

  6. Preliminary results of spatially resolved ECR ion beam profile investigations

    International Nuclear Information System (INIS)

    Panitzsch, L.; Stalder, M.; Wimmer-Schweingruber, R.F.

    2012-01-01

    The profile of an ion beam produced in an Electron Cyclotron Resonance Ion Source (ECRIS) can vary greatly depending on the source settings and the ion-optical tuning. Strongly focussed ion beams form circular structures (hollow beams) as predicted by simulations and observed in experiments. Each of the rings is predicted to be dominated by ions with same or at least similar m/q-ratios due to ion-optical effects. To check this we performed a series of preliminary investigations to test the required tuning capabilities of our ion source. This includes beam focussing (A) and beam steering (B) using a 3D-movable extraction. Having tuned the source to deliver a beam of strongly focussed ions of different ion species and having steered this beam to match the transmittance area of the sector magnet we also recorded the ion charge state distribution of the strongly focussed beam profile at different, spatially limited positions (C). The preliminary results will be introduced within this paper: it appears that our 3D-movable extraction is very efficient to steer and to focus the beam strongly. The paper is followed by the slides of the presentation. (authors)

  7. Comparison of image quality between mammography dedicated monitor and UHD 4K monitor, using standard mammographic phantom: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Young; Cha, Soon Joo; Hong, Sung Hwan; Kim, Su Young; Kim, Yong Hoon; Kim, You Sung; Kim, Jeong A [Dept. of Radiology, Inje Unveristy Ilsan Paik Hospital, Goyang (Korea, Republic of)

    2017-03-15

    Using standard mammographic phantom images, we compared the image quality obtained between a mammography dedicated 5 megapixel monitor (5M) and a UHD 4K (4K) monitor with digital imaging and communications in medicine display, to investigate the possibility of clinical application of 4K monitors. Three different exposures (autoexposure, overexposure and underexposure) images of mammographic phantom were obtained, and six radiologists independently evaluated the images in 5M and 4K without image modulation, by scoring of fibers, groups of specks and masses within the phantom image. The mean score of each object on both monitors was independently analyzed, using t-test and interobserver reliability by intraclass correlation coefficient (ICC) of SPSS. The overall mean scores of fiber, group of specks, and mass in 5M were 4.25, 3.92, and 3.28 respectively, and scores obtained in 4K monitor were 3.81, 3.58, and 3.14, respectively. No statistical difference was seen in scores of fiber and mass between the two monitors at all exposure conditions, but the score of group of specks in 4K was statistically lower in the overall (p = 0.0492) and in underexposure conditions (p = 0.012). The ICC for interobserver reliability was excellent (0.874). Our study suggests that since the mammographic phantom images are appropriate with no significant difference in image quality observed between the two monitors, the 4K monitor could be used for clinical studies. Since this is a small preliminary study using phantom images, the result may differ in actual mammographic images, and subsequent investigation with clinical mammographic images is required.

  8. Evaluation of image quality and dose in thoracic spiral CT examination in patients with pulmonary carcinoma. Preliminary results

    International Nuclear Information System (INIS)

    Moran-Blanco, L. M.; Rodriguez-Gonzalez, R.; Calzado-Cantera, A.; Arenas de Pablo, A.; Baeza-Trujillo, M.; Cuevas-Ibanez, A.; Garcia-Castano, B.; Gomez-Leon, N.; Turrero-Nogues, A.; Moran-Penco, P.

    2002-01-01

    We have applied criteria for CT quality defined in the European Guidelines to a samples of thoracic CT examinations for the indication of pulmonary carcinoma of 5 institutions of the Community of Madrid that have spiral CT equipment. The selected examinations have been evaluated independently by five radiologists to determine the degree of adherence to the quality criteria for image defined in the Guidelines s for examinations of general thorax. Dosimetric measurements carried out in parallel have served to estimate the values of CT (CTDI w ) dose indices, dose-length product (DLP) and effective dose for every patient. The result show a high global adherence to the quality criteria (96%), with averages per institution being between 94% (in two institutions) and 98% (in three institutions). There are 10 of 16 criteria that are adhered to in all examinations of the sample: those which are not adhered to systematically are: two of visualization (1.1 and 1.4), with 92-96% fulfillment, and four of critical reproduction (2.6; 2.8; 2.9 and 2.10), with percentages of adherence between 91% and 96%. The average CTDI w values per institution are in the interval 12.9-19.1 mGy; those of DLP between 263 and 577 mGy cm and those of effective dose between 4.2 and 9.2 mSv. The DLP-image quality correlation in institutions with the best image quality was null in two of them and direct and moderate in the third. In both institutions with the poorest image: (Author) 20 refs

  9. Preliminary Results of the CASCADE Hidden Sector Photon Search

    CERN Document Server

    Woollett, Nathan; Burt, Graeme; Chattopadhyay, Swapan; Dainton, John; Dexter, Amos; Goudket, Phillipe; Jenkins, Michael; Kalliokoski, Matti; Moss, Andrew; Pattalwar, Shrikant; Thakker, Trina; Williams, Peter

    2015-01-01

    Light shining through a wall experiments can be used to make measurements of photon-WISP couplings. The first stage of the CASCADE experiment at the Cockcroft Institute of Accelerator Science and Technology is intended to be a proof-of-principle experiment utilising standard microwave technologies to make a modular, cryogenic HSP detector to take advantage of future high-power superconducting cavity tests. In these proceedings we will be presenting the preliminary results of the CASCADE LSW experiment showing a peak expected exclusion of $1.10 \\times 10^{-8}$ in the mass range from 1.96$\\mu$eV to 5.38$\\mu$eV, exceeding current limits.

  10. V and V Efforts of Auroral Precipitation Models: Preliminary Results

    Science.gov (United States)

    Zheng, Yihua; Kuznetsova, Masha; Rastaetter, Lutz; Hesse, Michael

    2011-01-01

    Auroral precipitation models have been valuable both in terms of space weather applications and space science research. Yet very limited testing has been performed regarding model performance. A variety of auroral models are available, including empirical models that are parameterized by geomagnetic indices or upstream solar wind conditions, now casting models that are based on satellite observations, or those derived from physics-based, coupled global models. In this presentation, we will show our preliminary results regarding V&V efforts of some of the models.

  11. Ambient Assisted Living and ageing: preliminary results of RITA project.

    Science.gov (United States)

    Aquilano, Michela; Cavallo, Filippo; Bonaccorsi, Manuele; Esposito, Raffaele; Rovini, Erika; Filippi, Massimo; Esposito, Dario; Dario, Paolo; Carrozza, Maria Chiara

    2012-01-01

    The ageing of population is a social phenomenon that most of worldwide countries are facing. They are, and will be even more in the future, indeed trying to find solutions for improving quality of life of their elderly citizens. The project RITA wants to demonstrate that an update of the current socio-medical services with an Ambient Assisted Living (AAL) approach could improve the service efficiency and the quality of life of both elderly and caregiver. This paper presents the preliminary results obtained in RITA.

  12. Preliminary Results of BTDF Calibration of Transmissive Solar Diffusers for Remote Sensing

    Science.gov (United States)

    Georgiev, Georgi T.; Butler, James J.; Thome, Kurt; Cooksey, Catherine; Ding, Leibo

    2016-01-01

    Satellite instruments operating in the reflected solar wavelength region require accurate and precise determination of the optical properties of their diffusers used in pre-flight and post-flight calibrations. The majority of recent and current space instruments use reflective diffusers. As a result, numerous Bidirectional Reflectance Distribution Function (BRDF) calibration comparisons have been conducted between the National Institute of Standards and Technology (NIST) and other industry and university-based metrology laboratories. However, based on literature searches and communications with NIST and other laboratories, no Bidirectional Transmittance Distribution Function (BTDF) measurement comparisons have been conducted between National Measurement Laboratories (NMLs) and other metrology laboratories. On the other hand, there is a growing interest in the use of transmissive diffusers in the calibration of satellite, air-borne, and ground-based remote sensing instruments. Current remote sensing instruments employing transmissive diffusers include the Ozone Mapping and Profiler Suite instrument (OMPS) Limb instrument on the Suomi-National Polar-orbiting Partnership (S-NPP) platform,, the Geostationary Ocean Color Imager (GOCI) on the Korea Aerospace Research Institute's (KARI) Communication, Ocean, and Meteorological Satellite (COMS), the Ozone Monitoring Instrument (OMI) on NASA's Earth Observing System (EOS) Aura platform, the Tropospheric Emissions: Monitoring of Pollution (TEMPO) instrument and the Geostationary Environmental Monitoring Spectrometer (GEMS).. This ensemble of instruments requires validated BTDF measurements of their on-board transmissive diffusers from the ultraviolet through the near infrared. This paper presents the preliminary results of a BTDF comparison between the NASA Diffuser Calibration Laboratory (DCL) and NIST on quartz and thin Spectralon samples.

  13. Preliminary results of BTDF calibration of transmissive solar diffusers for remote sensing

    Science.gov (United States)

    Georgiev, Georgi T.; Butler, James J.; Thome, Kurt; Cooksey, Catherine; Ding, Leibo

    2016-09-01

    Satellite instruments operating in the reflected solar wavelength region require accurate and precise determination of the optical properties of their diffusers used in pre-flight and post-flight calibrations. The majority of recent and current space instruments use reflective diffusers. As a result, numerous Bidirectional Reflectance Distribution Function (BRDF) calibration comparisons have been conducted between the National Institute of Standards and Technology (NIST) and other industry and university-based metrology laboratories. However, based on literature searches and communications with NIST and other laboratories, no Bidirectional Transmittance Distribution Function (BTDF) measurement comparisons have been conducted between National Measurement Laboratories (NMLs) and other metrology laboratories. On the other hand, there is a growing interest in the use of transmissive diffusers in the calibration of satellite, air-borne, and ground-based remote sensing instruments. Current remote sensing instruments employing transmissive diffusers include the Ozone Mapping and Profiler Suite instrument (OMPS) Limb instrument on the Suomi-National Polar-orbiting Partnership (S-NPP) platform,, the Geostationary Ocean Color Imager (GOCI) on the Korea Aerospace Research Institute's (KARI) Communication, Ocean, and Meteorological Satellite (COMS), the Ozone Monitoring Instrument (OMI) on NASA's Earth Observing System (EOS) Aura platform, the Tropospheric Emissions: Monitoring of Pollution (TEMPO) instrument and the Geostationary Environmental Monitoring Spectrometer (GEMS).. This ensemble of instruments requires validated BTDF measurements of their onboard transmissive diffusers from the ultraviolet through the near infrared. This paper presents the preliminary results of a BTDF comparison between the NASA Diffuser Calibration Laboratory (DCL) and NIST on quartz and thin Spectralon samples.

  14. Pilot Program for the implementation of the Regulation Doc. nr. 453 of the Ministry of Health in the Image Service of the Hospital Municipal Cardoso Fontes, Rio de Janeiro, Brazil - preliminary results

    International Nuclear Information System (INIS)

    Almeida, Claudio Domingues; Ferreira, Rubemar de Souza; Marechal, Maria Helena H.; Milano, Nelly Ester

    2000-01-01

    Overall quality in radiological protection and medical image depend largely on keeping certain safety standard and technical procedures in good levels. This way, In June 1998, the Ministry of Health published the document 453 - Guidelines of Radiological Protection to Medical and Dental practices defining different levels of actions and responsibility to radiological installation where the critical starting point was the necessity of a previous quality assurance program (QAP) into the radiological service. Preliminary results of a QAP realized in the Department of Radiology of a high complexity Hospital in Rio de Janeiro has showed that, although the importance of 453 regulation be recognizing, there is a few motivation for implementing it. Besides, during 1999 was possible identify losses of 14,9 % related only to the repetition of exposures in the patients, reflecting in terms of cost about of U$ 70,000 a year. Results suggest that loss of 54% of total film are due to under or over exposures and 20% are due to inadequate positioning either film or patient, evidencing the need of training the technical and medical staff. (author)

  15. Preliminary test results and CFD analysis for moderator circulation test at Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, H.T. [Korea Atomic Energy Research Inst., Daejeon (Korea, Republic of); Im, S.H.; Sung, H.J. [Korea Advanced Inst. of Science and Tech., Daejeon (Korea, Republic of); Seo, H.; Bang, I.C. [Ulsan National Inst. of Science and Tech., Ulsan (Korea, Republic of)

    2014-07-01

    Korea Atomic Energy Research Institute (KAERI) is carrying out a scaled-down moderator test program to simulate the CANDU6 moderator circulation phenomena during steady state operation and accident conditions. This research program includes the construction of the Moderator Circulation Test (MCT) facility, production of the validation data for self-reliant CFD tools, and development of optical measurement system using the Particle Image Velocimetry (PIV). The MCT facility includes a primary circulation loop (pipe lines, a primary side pump, a heat exchanger, valves, flow meters) and a secondary side loop (pipe lines, a secondary side pump, and an external cooling tower). The loop leakage test and non-heating test are performed in the present work. In the present work the PIV technique is used to measure the velocity distributions in the scaled moderator tank of MCT under iso-thermal test conditions. The preliminary PIV measurement data are obtained and compared with CFX code predictions. (author)

  16. Preliminary test results and CFD analysis for moderator circulation test at Korea

    International Nuclear Information System (INIS)

    Kim, H.T.; Im, S.H.; Sung, H.J.; Seo, H.; Bang, I.C.

    2014-01-01

    Korea Atomic Energy Research Institute (KAERI) is carrying out a scaled-down moderator test program to simulate the CANDU6 moderator circulation phenomena during steady state operation and accident conditions. This research program includes the construction of the Moderator Circulation Test (MCT) facility, production of the validation data for self-reliant CFD tools, and development of optical measurement system using the Particle Image Velocimetry (PIV). The MCT facility includes a primary circulation loop (pipe lines, a primary side pump, a heat exchanger, valves, flow meters) and a secondary side loop (pipe lines, a secondary side pump, and an external cooling tower). The loop leakage test and non-heating test are performed in the present work. In the present work the PIV technique is used to measure the velocity distributions in the scaled moderator tank of MCT under iso-thermal test conditions. The preliminary PIV measurement data are obtained and compared with CFX code predictions. (author)

  17. Method of preliminary localization of the iris in biometric access control systems

    Science.gov (United States)

    Minacova, N.; Petrov, I.

    2015-10-01

    This paper presents a method of preliminary localization of the iris, based on the stable brightness features of the iris in images of the eye. In tests on images of eyes from publicly available databases method showed good accuracy and speed compared to existing methods preliminary localization.

  18. Primary progressive aphasia patients evaluated using diffusion tensor imaging and voxel based volumetry-preliminary results

    Directory of Open Access Journals (Sweden)

    Fábio Pascotto de Oliveira

    2011-06-01

    Full Text Available There are individuals who have a progressive language deficit without presenting cognitive deficits in other areas. One of the diseases related to this presentation is primary progressive aphasia (PPA. OBJECTIVE: Identify by means of diffusion tensor imaging (DTI and measurements of cortical volume, brain areas that lead to dysphasia when presenting signs of impaired connectivity or reduced volume. METHOD: Four patients with PPA were evaluated using DTI, and measurements of cortical volumes in temporal areas. These patients were compared with two normal volunteers. RESULTS: There is a trend to a difference in the number and volume of related fibers between control group and patients with PPA. Comparing cortical volumes in temporal areas between groups yielded a trend to a smaller volume in PPA patients. CONCLUSION: Patients with PPA have a trend to impairment in cortical and subcortical levels regarding relevant areas.

  19. Brain connectivity study of brain tumor patients using MR-PET data: preliminary results

    International Nuclear Information System (INIS)

    Mendes, Ana Carina; Ribeiro, Andre Santos; Oros-Peusquens, Ana Maria; Langen, Karl Josef; Shah, Jon; Ferreira, Hugo Alexandre

    2015-01-01

    Brain activity results from anatomical and functional connections that can be disrupted or altered due to trauma or lesion. This work presents a first approach on the study of whole-brain connectivity of brain tumor patients using the Multimodal Imaging Brain Connectivity (MIBCA) toolbox. Two patients with glioblastoma lesions located in the left hemisphere (one in the motor cortex and the other in the temporal lobe) underwent simultaneous MRI and dynamic PET scans using a 3T MRI scanner with a BrainPET insert. The following data was acquired: T1-w MPRAGE (1x1x1mm 3 ), DTI (dir=30, b=0,800s/mm2, 2x2x2mm 3 ), and dynamic 18F-FET PET. The MIBCA toolbox was used to automatically pre-process MRI-PET data and to derive imaging and connectivity metrics from the multimodal data. Computed metrics included: cortical thickness from T1-w data; mean diffusivity (MD), fractional anisotropy (FA), node degree, clustering coefficient and pairwise ROI fibre tracking (structural connectivity) from DTI data; and standardized uptake value (SUV) from PET data. For all the metrics, the differences between left and right hemispherical structures were obtained, followed by a 25% threshold (except for SUV thresholded at 15%). Data was visualized in a connectogram, and both structural connectivity and metrics were studied in regions surrounding lesions. Preliminary results showed increased SUV values in regions surrounding the tumor for both patients. Patients also showed changes in structural connectivity involving these regions and also other more spatially distant regions such as the putamen and the pallidum, including decreased number of fibers between the subcortical structures themselves and with frontal regions. These findings suggest that the presence of a tumor may alter both local and more distant structural connections. Presently, a larger patient sample is being studied along with the inclusion of a control group to test the consistency of the findings.

  20. Brain connectivity study of brain tumor patients using MR-PET data: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Mendes, Ana Carina [Institute of Biophysics and Biomedical Engineering, Faculty of Sciences of the University of Lisbon (Portugal); Ribeiro, Andre Santos [Institute of Biophysics and Biomedical Engineering, Faculty of Sciences of the University of Lisbon (Portugal); Centre for Neuropsychopharmacology, Division of Brain Sciences, Department of Medicine, Imperial College London, London (United Kingdom); Oros-Peusquens, Ana Maria; Langen, Karl Josef; Shah, Jon [Institute of Neuroscience and Medicine - 4, Forschungszentrum Juelich (Germany); Ferreira, Hugo Alexandre [Institute of Biophysics and Biomedical Engineering, Faculty of Sciences of the University of Lisbon (Portugal)

    2015-05-18

    Brain activity results from anatomical and functional connections that can be disrupted or altered due to trauma or lesion. This work presents a first approach on the study of whole-brain connectivity of brain tumor patients using the Multimodal Imaging Brain Connectivity (MIBCA) toolbox. Two patients with glioblastoma lesions located in the left hemisphere (one in the motor cortex and the other in the temporal lobe) underwent simultaneous MRI and dynamic PET scans using a 3T MRI scanner with a BrainPET insert. The following data was acquired: T1-w MPRAGE (1x1x1mm{sup 3}), DTI (dir=30, b=0,800s/mm2, 2x2x2mm{sup 3}), and dynamic 18F-FET PET. The MIBCA toolbox was used to automatically pre-process MRI-PET data and to derive imaging and connectivity metrics from the multimodal data. Computed metrics included: cortical thickness from T1-w data; mean diffusivity (MD), fractional anisotropy (FA), node degree, clustering coefficient and pairwise ROI fibre tracking (structural connectivity) from DTI data; and standardized uptake value (SUV) from PET data. For all the metrics, the differences between left and right hemispherical structures were obtained, followed by a 25% threshold (except for SUV thresholded at 15%). Data was visualized in a connectogram, and both structural connectivity and metrics were studied in regions surrounding lesions. Preliminary results showed increased SUV values in regions surrounding the tumor for both patients. Patients also showed changes in structural connectivity involving these regions and also other more spatially distant regions such as the putamen and the pallidum, including decreased number of fibers between the subcortical structures themselves and with frontal regions. These findings suggest that the presence of a tumor may alter both local and more distant structural connections. Presently, a larger patient sample is being studied along with the inclusion of a control group to test the consistency of the findings.

  1. DECOMPOSITION OF TARS IN MICROWAVE PLASMA – PRELIMINARY RESULTS

    Directory of Open Access Journals (Sweden)

    Mateusz Wnukowski

    2014-07-01

    Full Text Available The paper refers to the main problem connected with biomass gasification - a presence of tar in a product gas. This paper presents preliminary results of tar decomposition in a microwave plasma reactor. It gives a basic insight into the construction and work of the plasma reactor. During the experiment, researches were carried out on toluene as a tar surrogate. As a carrier gas for toluene and as a plasma agent, nitrogen was used. Flow rates of the gases and the microwave generator’s power were constant during the whole experiment. Results of the experiment showed that the decomposition process of toluene was effective because the decomposition efficiency attained above 95%. The main products of tar decomposition were light hydrocarbons and soot. The article also gives plans for further research in a matter of tar removal from the product gas.

  2. Preliminary results of the alpha particle registration intercomparison ALRIT

    International Nuclear Information System (INIS)

    Paretzke, H.G.

    1976-01-01

    In view of the widespread interest in alpha particle registration with solid state nuclear track detectors, an international intercomparison of such measurements has been arranged. Sixteen sets of fourteen detectors each were sent to GSF-Neuherberg, there irradiated carefully with different alpha particle fields, and then returned for evaluation. Fourteen irradiation runs were made for each set simulating seven different irradiation situations commonly encountered in practical applications. The preliminary results of this intercomparison reported in this paper are based on the results of eight sets. They show good agreement with respect to the determination of track densities in the case of vertical incident alpha particles. Also the results obtained for determination of particle energies and angle of incidence in most cases were rather accurate. However, apparently it is still rather difficult to determine accurately and precisely the specific activity of alpha emitters on a thick filter positioned at some distance, i.e. for the case of 2π-incidence and a broad energy spectrum. (orig.) [de

  3. The demand factors for cesareans in Portugal – some preliminary results

    OpenAIRE

    Tavares, Aida Isabel; Rocha, Tania

    2012-01-01

    The aim of this work is to determine the demand factors for cesareans in Portugal. This work is exploratory and preliminary. Data is aggregated in NUTSII , for the period 2002-10. The number of cesareans performed is count data which requires the estimation of this panel data by a negative binomial with fixed effects. The main result is the evidence that there may be induced demand for cesareans in Portugal. Further research is needed.

  4. Preliminary test of an imaging probe for nuclear medicine using hybrid pixel detectors

    International Nuclear Information System (INIS)

    Bertolucci, E.; Maiorino, M.; Mettivier, G.; Montesi, M.C.; Russo, P.

    2002-01-01

    We are investigating the feasibility of an intraoperative imaging probe for lymphoscintigraphy with Tc-99m tracer, for sentinel node radioguided surgery, using the Medipix series of hybrid detectors coupled to a collimator. These detectors are pixelated semiconductor detectors bump-bonded to the Medipix1 photon counting read-out chip (64x64 pixel, 170 μm pitch) or to the Medipix2 chip (256x256 pixel, 55 μm pitch), developed by the European Medipix collaboration. The pixel detector we plan to use in the final version of the probe is a semi-insulating GaAs detector or a 1-2 mm thick CdZnTe detector. For the preliminary tests presented here, we used 300-μm thick silicon detectors, hybridized via bump-bonding to the Medipix1 chip. We used a tungsten parallel-hole collimator (7 mm thick, matrix array of 64x64 100 μm circular holes with 170 μm pitch), and a 22, 60 and 122 keV point-like (1 mm diameter) radioactive sources, placed at various distances from the detector. These tests were conducted in order to investigate the general feasibility of this imaging probe and its resolving power. Measurements show the high resolution but low efficiency performance of the detector-collimator set, which is able to image the 122 keV source with <1 mm FWHM resolution

  5. Preliminary results on the Arecibo Pisces-Perseus Supercluster Survey

    Science.gov (United States)

    Cortes, Rosemary; Lebron, Mayra; Jones, Michael G.; Koopmann, Rebecca A.; Haynes, Martha P.; APPSS Team, Undergraduate ALFALFA Team, and the ALFALFA Team

    2018-01-01

    The Arecibo Pisces-Perseus Supercluster Survey (APPSS) aims to exploit the Baryonic Tully-Fisher Relation to derive distances and peculiar velocities of galaxies in and near the main ridge of the Pisces-Perseus Supercluster (PPS), one of the most prominent features of the Cosmic Web in the nearby Universe. The sample of galaxies contains ~ 600 sources in the low-mass range (8 Team institutions in which each group contributes to the analysis of a subset of the HI PPS data. In this poster, we will present the contributions of the U.P.R. team to the APPSS project. We will show the procedure used for the Arecibo HI data analysis, including some examples, and will show our preliminary results.

  6. Preliminary investigations into macroscopic attenuated total reflection-fourier transform infrared imaging of intact spherical domains: spatial resolution and image distortion.

    Science.gov (United States)

    Everall, Neil J; Priestnall, Ian M; Clarke, Fiona; Jayes, Linda; Poulter, Graham; Coombs, David; George, Michael W

    2009-03-01

    This paper describes preliminary investigations into the spatial resolution of macro attenuated total reflection (ATR) Fourier transform infrared (FT-IR) imaging and the distortions that arise when imaging intact, convex domains, using spheres as an extreme example. The competing effects of shallow evanescent wave penetration and blurring due to finite spatial resolution meant that spheres within the range 20-140 microm all appeared to be approximately the same size ( approximately 30-35 microm) when imaged with a numerical aperture (NA) of approximately 0.2. A very simple model was developed that predicted this extreme insensitivity to particle size. On the basis of these studies, it is anticipated that ATR imaging at this NA will be insensitive to the size of intact highly convex objects. A higher numerical aperture device should give a better estimate of the size of small spheres, owing to superior spatial resolution, but large spheres should still appear undersized due to the shallow sampling depth. An estimate of the point spread function (PSF) was required in order to develop and apply the model. The PSF was measured by imaging a sharp interface; assuming an Airy profile, the PSF width (distance from central maximum to first minimum) was estimated to be approximately 20 and 30 microm for IR bands at 1600 and 1000 cm(-1), respectively. This work has two significant limitations. First, underestimation of domain size only arises when imaging intact convex objects; if surfaces are prepared that randomly and representatively section through domains, the images can be analyzed to calculate parameters such as domain size, area, and volume. Second, the model ignores reflection and refraction and assumes weak absorption; hence, the predicted intensity profiles are not expected to be accurate; they merely give a rough estimate of the apparent sphere size. Much further work is required to place the field of quantitative ATR-FT-IR imaging on a sound basis.

  7. Synthesis and preliminary evaluation of carbon-11-meta-hydroxyephedrine: A false transmitter agent for heart neuronal imaging

    International Nuclear Information System (INIS)

    Rosenspire, K.C.; Haka, M.S.; Van Dort, M.E.; Jewett, D.M.; Gildersleeve, D.L.; Schwaiger, M.; Wieland, D.M.

    1990-01-01

    Carbon-11-meta-hydroxyephedrine is a new radiotracer developed for mapping the sympathetic nerves of the heart. Carbon-11-meta-hydroxyephedrine is synthesized by direct N-methylation of metaraminol with [ 11 C]methyl iodide in dimethyl formamide/dimethyl sulfoxide and purified by semi-preparative reversed-phase HPLC. Total synthesis time is 45 min from end-of-bombardment. Carbon-11-meta-hydroxyephedrine is produced in 40%-50% corrected radiochemical yield with a specific activity of 900 Ci/mmol. Routine radiochemical and chemical purity are 95% and 98%, respectively. Biodistribution studies in rats show high myocardial uptake. Pretreatment with desipramine, a drug known to selectively block neuronal uptake, results in a 92% decrease in tracer accumulation in the myocardium. Metabolic studies in guinea pigs show less than 5% metabolites in heart tissue 30 min after intravenous injection suggesting that [ 11 C]meta-hydroxyephedrine is suitable for kinetic modeling. These preliminary results support this new tracer as a clinical agent for neuronal imaging of the heart

  8. Radiology workstation for mammography: preliminary observations, eyetracker studies, and design

    Science.gov (United States)

    Beard, David V.; Johnston, Richard E.; Pisano, Etta D.; Hemminger, Bradley M.; Pizer, Stephen M.

    1991-07-01

    For the last four years, the UNC FilmPlane project has focused on constructing a radiology workstation facilitating CT interpretations equivalent to those with film and viewbox. Interpretation of multiple CT studies was originally chosen because handling such large numbers of images was considered to be one of the most difficult tasks that could be performed with a workstation. The authors extend the FilmPlane design to address mammography. The high resolution and contrast demands coupled with the number of images often cross- compared make mammography a difficult challenge for the workstation designer. This paper presents the results of preliminary work with workstation interpretation of mammography. Background material is presented to justify why the authors believe electronic mammographic workstations could improve health care delivery. The results of several observation sessions and a preliminary eyetracker study of multiple-study mammography interpretations are described. Finally, tentative conclusions of what a mammographic workstation might look like and how it would meet clinical demand to be effective are presented.

  9. Dissolved air flotation for treating wastewater of the nuclear industry. Preliminary results

    International Nuclear Information System (INIS)

    Ortiz-Oliveros, H.B.; Jimenez-Moleon, M.C.; Cruz-Gonzalez, D.

    2012-01-01

    Preliminary testing of dissolved air flotation (DAF) for wastewater treatment is presented. A combined coagulation-flocculation/DAF column system is used to remove oil and 60 Co from nuclear industry wastewater. In this work, operational conditions and coagulant/flocculant concentrations are optimized by varying pH. Determinations of air-solids ratio (G/S), retention time (θ), pressure (P), volume of depressurized air-water mixture (V), turbidity and 60 Co concentrations are reported. The effect of the treatment on the efficiency of separation of oily residues is also discussed. The results establish that the coagulant/flocculant system, formed by a modified polyamine (25 mgL -1 ) and a slightly cationic polyacrylamide (1.5 mgL -1 ), under specific operational conditions (pH = 7, mixing intensity Im 1 = 300 s -1 and Im 2 = 30 s -1 ), allowed the destabilization of colloidal matter, resulting in resistant flocs. It was concluded that by using G/S = 0.3, θ = 15 min, P = 620 kPa and V = 0.0012 m 3 , the greatest percentage removals of oil, turbidity, total cobalt and 60 Co were obtained. These preliminary results then show that dissolved air flotation represents a good alternative for treatment of nuclear industry wastewater contaminated with radionuclides. (author)

  10. The RPC-based IFR system at BaBar experiment: preliminary results

    International Nuclear Information System (INIS)

    Piccolo, Davide; Palano, A.; Bagnasco, S.; Buzzo, A.; Contri, R.; Crosetti, G.; Lo Vetere, M.; Macri, M.; Monge, R.; Passaggio, S.; Patrignani, C.; Robutti, E.; Santroni, A.; Anulli, F.; Baldini, R.; Calcaterra, A.; De Sangro, R.; Falciai, D.; Finocchiaro, G.; Patteri, P.; Peruzzi, I.; Piccolo, M.; Yu, Z.; Zallo, A.; Cavallo, N.; De Nardo, G.; Fabozzi, F.; Gatto, C.; Lista, L.; Paolucci, P.; Sciacca, C.; Bionta, R.; Wright, D.; Band, H.; Johnson, J.

    2002-01-01

    The IFR system is a RPC-based detector used to identify muons and neutral hadrons in the BaBar experiment at PEP II machine in SLAC. The RPC system can be used to reconstruct the trajectory of muons, pions and neutral hadrons interacting in the iron of the IFR. The different range and hit pattern allow to discriminate different particles crossing the IFR. An overview of the system design and the preliminary results on the IFR performances are reported

  11. The RPC-based IFR system at BaBar experiment preliminary results

    CERN Document Server

    Piccolo, D; Bagnasco, S; Baldini, R; Band, H R; Bionta, R; Buzzo, A; Calcaterra, A; Cavallo, N; Contri, R; Crosetti, G; De Nardo, Gallieno; De Sangro, R; Fabozzi, F; Falciai, D; Finocchiaro, G; Gatto, C; Johnson, J; Lista, L; Lo Vetere, M; Macri, M; Monge, R; Palano, A; Paolucci, P; Passaggio, S; Patrignani, C; Patteri, P; Peruzzi, I; Piccolo, M; Robutti, E; Santroni, A; Sciacca, C; Wright, D; Yu, Z; Zallo, A

    2002-01-01

    The IFR system is a RPC-based detector used to identify muons and neutral hadrons in the BaBar experiment at PEP II machine in SLAC. The RPC system can be used to reconstruct the trajectory of muons, pions and neutral hadrons interacting in the iron of the IFR. The different range and hit pattern allow to discriminate different particles crossing the IFR. An overview of the system design and the preliminary results on the IFR performances are reported.

  12. KEEP Reading Research 1974: Overall Strategy and Preliminary Results. Technical Report No. 23.

    Science.gov (United States)

    Tharp, Roland G.; And Others

    Reading research is an important aspect of the Kamehameha Early Education Program. This report describes the overall strategy of the reading research program, which is based on a conceptual framework that divides lines of inquiry into motivation, linguistics, instructional procedures, and correlational analysis. Preliminary results for each of…

  13. The administration of psilocybin to healthy, hallucinogen-experienced volunteers in a mock-functional magnetic resonance imaging environment: a preliminary investigation of tolerability.

    Science.gov (United States)

    Carhart-Harris, Robin L; Williams, Tim M; Sessa, Ben; Tyacke, Robin J; Rich, Ann S; Feilding, Amanda; Nutt, David J

    2011-11-01

    This study sought to assess the tolerability of intravenously administered psilocybin in healthy, hallucinogen-experienced volunteers in a mock-magnetic resonance imaging environment as a preliminary stage to a controlled investigation using functional magnetic resonance imaging to explore the effects of psilocybin on cerebral blood flow and activity. The present pilot study demonstrated that up to 2 mg of psilocybin delivered as a slow intravenous injection produces short-lived but typical drug effects that are psychologically and physiologically well tolerated. With appropriate care, this study supports the viability of functional magnetic resonance imaging work with psilocybin.

  14. Preliminary investigation into aerosol mobilization resulting from fusion reactor disruptions

    International Nuclear Information System (INIS)

    Sharpe, J.P.; Bourham, M.A.; Gilligan, J.G.

    1996-01-01

    An experimental system has been developed to study disruption-induced aerosol mobilization for fusion accident analysis. The SIRENS high heat flux facility at North Carolina State University has been modified to closely simulate disruption conditions expected in tokamak reactors. A hot vapor is formed by an ablation-controlled arc and expansion cooled into a glass chamber, where particle condensation and growth occur. The particles are collected and analyzed for relevant transport properties (e.g. size distribution and shape). Particle characterization methods are discussed, and preliminary results based on simple analysis techniques are given. 2 refs., 6 figs

  15. Escherichia coli O26 IN RAW BUFFALO MILK: PRELIMINARY RESULTS

    Directory of Open Access Journals (Sweden)

    A. Rella

    2013-02-01

    Full Text Available Escherichia coli O26 is considered to be one of the most important food-borne pathogen. In this study, 120 buffalo milk samples collected in Lazio and in Apulia regions were tested for the presence of E. coli O26. One buffalo milk sample (0,8% tested positive for E. coli O26; the isolate was positive at the verocytotoxicity test and it showed resistance properties to different antimicrobial classes. These preliminary results highlight the need to monitor the foods of animal origin used for production and eaten by a wide range of persons, respect VTEC organism.

  16. SmallWorld Behavior of the Worldwide Active Volcanoes Network: Preliminary Results

    Science.gov (United States)

    Spata, A.; Bonforte, A.; Nunnari, G.; Puglisi, G.

    2009-12-01

    We propose a preliminary complex networks based approach in order to model and characterize volcanoes activity correlation observed on a planetary scale over the last two thousand years. Worldwide volcanic activity is in fact related to the general plate tectonics that locally drives the faults activity, that in turn controls the magma upraise beneath the volcanoes. To find correlations among different volcanoes could indicate a common underlying mechanism driving their activity and could help us interpreting the deeper common dynamics controlling their unrest. All the first evidences found testing the procedure, suggest the suitability of this analysis to investigate global volcanism related to plate tectonics. The first correlations found, in fact, indicate that an underlying common large-scale dynamics seems to drive volcanic activity at least around the Pacific plate, where it collides and subduces beneath American, Eurasian and Australian plates. From this still preliminary analysis, also more complex relationships among volcanoes lying on different tectonic margins have been found, suggesting some more complex interrelationships between different plates. The understanding of eventually detected correlations could be also used to further implement warning systems, relating the unrest probabilities of a specific volcano also to the ongoing activity to the correlated ones. Our preliminary results suggest that, as for other many physical and biological systems, an underlying organizing principle of planetary volcanoes activity might exist and it could be a small-world principle. In fact we found that, from a topological perspective, volcanoes correlations are characterized by the typical features of small-world network: a high clustering coefficient and a low characteristic path length. These features confirm that global volcanoes activity is characterized by both short and long-range correlations. We stress here the fact that numerical simulation carried out in

  17. Preliminary examples of 3D vector flow imaging

    DEFF Research Database (Denmark)

    Pihl, Michael Johannes; Stuart, Matthias Bo; Tomov, Borislav Gueorguiev

    2013-01-01

    This paper presents 3D vector flow images obtained using the 3D Transverse Oscillation (TO) method. The method employs a 2D transducer and estimates the three velocity components simultaneously, which is important for visualizing complex flow patterns. Data are acquired using the experimental ult...... as opposed to magnetic resonance imaging (MRI). The results demonstrate that the 3D TO method is capable of performing 3D vector flow imaging.......This paper presents 3D vector flow images obtained using the 3D Transverse Oscillation (TO) method. The method employs a 2D transducer and estimates the three velocity components simultaneously, which is important for visualizing complex flow patterns. Data are acquired using the experimental...... ultrasound scanner SARUS on a flow rig system with steady flow. The vessel of the flow-rig is centered at a depth of 30 mm, and the flow has an expected 2D circular-symmetric parabolic prole with a peak velocity of 1 m/s. Ten frames of 3D vector flow images are acquired in a cross-sectional plane orthogonal...

  18. Preliminary results from the MINERvA experiment

    International Nuclear Information System (INIS)

    Harris, Deborah A.

    2011-01-01

    The MINERvA experiment, operating since 2009 in the NuMI neutrino beam line at Fermilab, has collected neutrino and antineutrino scattering data on a variety of nuclear targets. The detector is designed to identify events originating in plastic scintillator, lead, carbon, iron, water, and liquid helium. The goal of the experiment is to measure inclusive and exclusive cross sections for neutrino and antineutrino with much greater precision than previous experiments. We present preliminary kinematic distributions for charged current quasi-elastic scattering and other processes.

  19. Using R2* values to evaluate brain tumours on magnetic resonance imaging: Preliminary results

    International Nuclear Information System (INIS)

    Liu, Zhenghua; Liao, Haibo; Yin, Jianhua; Li, Yanfang

    2014-01-01

    To determine the usefulness of the R2* value in assessing the histopathological grade of glioma at magnetic resonance imaging and differentiating various brain tumours. Sixty-four patients with brain tumours underwent R2* mapping and diffusion-weighted imaging examinations. ANOVA was performed to analyse R2* values among four groups of glioma and among high-grade gliomas (grades III and IV), low-grade gliomas (grades I and II), meningiomas, and brain metastasis. Spearman's correlation coefficients were used to determine the relationships between the R2* values or apparent diffusion coefficient (ADC) and the histopathological grade of gliomas. R2* values of low- and high-grade gliomas were analysed with the receiver-operator characteristic curve. R2* values were significantly different among high-grade gliomas, low-grade gliomas, meningiomas, and brain metastasis, but not between grade I and grade II or between grade III and grade IV. The R2* value (18.73) of high-grade gliomas provided a very high sensitivity and specificity for differentiating low-grade gliomas. A strong correlation existed between the R2* value and the pathological grade of gliomas. R2* mapping is a useful sequence for determining grade of gliomas and in distinguishing benign from malignant tumours. R2* values are better than ADC for characterising gliomas. (orig.)

  20. FAIR imaging of the liver. A preliminary study

    International Nuclear Information System (INIS)

    Kiryu, Shigeru; Machida, Toru; Noda, Masanobu

    1998-01-01

    Flow-sensitive alternating inversion recovery (FAIR) technique has recently been introduced for perfusion or functional MR studies of the brain. In the imaging of liver neoplasms, the evaluation of tumor vascularity is important for diagnosis, and therefore the FAIR technique may potentially complement liver MR imaging. The purpose of this study was to evaluate the usefulness of a FAIR sequence in MR imaging of the liver and to compare it with arterial-phase images of dynamic MR imaging. One volunteer and six patients with focal hepatic lesions (one with hepatocellular carcinoma (HCC), three with metastasis, and two with cavernous hemangioma) underwent FAIR. Short TI (600 ms) and long TI (1200 ms) images were obtained during breath-hold. In normal volunteers, the vessels generated remarkably bright signal in both short and long TI. Signal intensity of liver parenchyma was low in short TI, and became stronger in long TI. Two HCC (in one patient) (100%), one hemangioma (50%), and three metastases (100%) were well delineated as bright lesions. One HCC produced peripheral high intensity in short-TI FAIR image, and this finding was consistent with the result of dynamic MR study. Another HCC, which showed no clear enhancement in the arterial-phase dynamic MRI, was visualized only in long-TI FAIR. One hemangioma, which was clearly seen in FAIR image, showed rapid and strong enhancement on dynamic MRI. It is concluded that FAIR is a promising technique for evaluation of vascularity of hepatic tumors without using contrast materials. (author)

  1. Vivo dosimetry using TLD detectors in prostate seed implants of I-125: preliminary results

    International Nuclear Information System (INIS)

    Sanchez-Reyes, A.; Pedro, A.; Bassas, P.; Duch, M. A.; Cros, M.; Mane, S.

    2011-01-01

    We present preliminary results of a new in vivo dosimetry technique that could allow to know immediately after implantation of the prostate if the dose distribution determined by the scheduler is similar to the actual dose measured with TLD detectors.

  2. 77 FR 66580 - Certain Preserved Mushrooms From India: Preliminary Results of Antidumping Duty Administrative...

    Science.gov (United States)

    2012-11-06

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-533-813] Certain Preserved Mushrooms... preserved mushrooms (mushrooms) from India. The period of review (POR) is February 1, 2011, through January... Preliminary Results of Antidumping Duty Administrative Review: Certain Preserved Mushrooms from India...

  3. Dynamic motion analysis of fetuses with central nervous system disorders by cine magnetic resonance imaging using fast imaging employing steady-state acquisition and parallel imaging: a preliminary result.

    Science.gov (United States)

    Guo, Wan-Yuo; Ono, Shigeki; Oi, Shizuo; Shen, Shu-Huei; Wong, Tai-Tong; Chung, Hsiao-Wen; Hung, Jeng-Hsiu

    2006-08-01

    The authors present a novel cine magnetic resonance (MR) imaging, two-dimensional (2D) fast imaging employing steady-state acquisition (FIESTA) technique with parallel imaging. It achieves temporal resolution at less than half a second as well as high spatial resolution cine imaging free of motion artifacts for evaluating the dynamic motion of fetuses in utero. The information obtained is used to predict postnatal outcome. Twenty-five fetuses with anomalies were studied. Ultrasonography demonstrated severe abnormalities in five of the fetuses; the other 20 fetuses constituted a control group. The cine fetal MR imaging demonstrated fetal head, neck, trunk, extremity, and finger as well as swallowing motions. Imaging findings were evaluated and compared in fetuses with major central nervous system (CNS) anomalies in five cases and minor CNS, non-CNS, or no anomalies in 20 cases. Normal motility was observed in the latter group. For fetuses in the former group, those with abnormal motility failed to survive after delivery, whereas those with normal motility survived with functioning preserved. The power deposition of radiofrequency, presented as specific absorption rate (SAR), was calculated. The SAR of FIESTA was approximately 13 times lower than that of conventional MR imaging of fetuses obtained using single-shot fast spin echo sequences. The following conclusions are drawn: 1) Fetal motion is no longer a limitation for prenatal imaging after the implementation of parallel imaging with 2D FIESTA, 2) Cine MR imaging illustrates fetal motion in utero with high clinical reliability, 3) For cases involving major CNS anomalies, cine MR imaging provides information on extremity motility in fetuses and serves as a prognostic indicator of postnatal outcome, and 4) The cine MR used to observe fetal activity is technically 2D and conceptually three-dimensional. It provides four-dimensional information for making proper and timely obstetrical and/or postnatal management

  4. Lumbar muscle activity during common lifts: a preliminary study using magnetic resonance imaging.

    Science.gov (United States)

    Mayer, John M; Graves, James E; Manini, Todd M; Nuzzo, James L; Ploutz-Snyder, Lori L

    2013-04-01

    The purpose of this preliminary study was to assess lumbar multifidus, erector spinae, and quadratus lumborum muscle activity during lifts as measured by changes in transverse relaxation time (T2) from magnetic resonance imaging (MRI). Thirteen healthy adults performed dynamic squat, stoop, and asymmetric stoop lifts at a standard load, with each lift followed by MRI. Increase in T2 for the multifidus and erector spinae was greater for the stoop than squat. No difference in T2 increase was noted between the multifidus and erector spinae for the squat or stoop. Increase in T2 for the contralateral multifidus was less for the asymmetric stoop than stoop. Future research using MRI and other biomechanical techniques is needed to fully characterize lumbar muscle activity during lifts for various populations, settings, postures, and loads.

  5. Chemical Analysis of the Moon at the Surveyor VII Landing Site: Preliminary Results.

    Science.gov (United States)

    Turkevich, A L; Franzgrote, E J; Patterson, J H

    1968-10-04

    The alpha-scattering experiment aboard Surveyor VII has provided a chemical analysis of the moon in the area of the crater Tycho. The preliminary results indicate a chemical composition similar to that already found at two mare sites, but with a lower concentration of elements of the iron group (titanium through copper).

  6. Aerosol composition in a stagnant air mass impacted by dense fogs: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Jacob, D.J.; Munger, J.W.; Waldman, J.M.; Hoffman, M.R.

    1984-01-01

    Over the last two winters, our research group has been investigating the chemical composition of fogwater and haze aerosol during wintertime stagnation episodes in the San Joaquin Valley of California. The valley is encompassed by mountain ranges. During the winter a strong subsidence inversion based below the natural boundaries of the valley restricts the ventilation of the air masses below the inversion. The residence time of an air parcel in the valley under these stagnation conditions is on the order of 8 days. Because the trapped air is very humid, stagnation episodes are associated with a persistent thick haze and frequent widespread nighttime fogs. During the winter 1982-1983 the authors sampled fog and haze at one site (Bakersfield); results from this preliminary study have been discussed in detail in a previous report. In the winter 1983-1984 the scale of the program was expanded in order to test hypotheses formulated as a result of first year data. The present paper first reports briefly on the 1982-1983 results and outlines the essential conclusions. They then describe the large-scale experiment conducted during the winter of 1983-1984, and discuss some preliminary fogwater data.

  7. Preliminary results of endorectal surface coil magnetic resonance imaging for local staging of prostate cancer

    NARCIS (Netherlands)

    Jager, G. J.; Barentsz, J. O.; de la Rosette, J. J.; Rosenbusch, G.

    1994-01-01

    To evaluate the effectiveness of endorectal surface coil (ERC) magnetic resonance imaging (MRI) in the local staging of adenocarcinoma of the prostate (ACP). A total of 23 patients who were considered candidates for radical prostatectomy because of clinically localized ACP were examined by ERC-MRI.

  8. Imaging cerebral activity in recovery from chronic traumatic brain injury: a preliminary report.

    Science.gov (United States)

    Lewis, David H; Bluestone, Judith P; Savina, Maryann; Zoller, William H; Meshberg, Emily B; Minoshima, Satoshi

    2006-07-01

    People in chronic phase of traumatic brain injury (TBI) are often told that there will be no further recovery in brain function, that they are in a "static phase." Holistic Approach to NeuroDevelopment and Learning Efficiency (HANDLE), an alternative therapy, aims to improve function by teaching a series of physical and mental activities that clients perform and encouraging changes in lifestyle. Five subjects (3 males) with chronic TBI (at least 3 years since ictus) completed the HANDLE Institute's program and were prospectively evaluated. Each had six regional cerebral blood flow (rCBF) single-photon emission computed tomography (SPECT) scans over 7 months (scans n= 30). Paired scans were performed with injection of Tc-99m ECD to image rCBF at rest and during the HANDLE "Crossed Arm Bounce" (CAB) exercise before the program, at 3-4 months into the program, and at 6-7 months, after the program had ended. SPECT images were analyzed statistically using Neurostat in which image sets were coregistered and warped into Talaraich atlas for pairwise subtraction between conditions. Group analysis of SPECT showed that CAB activated (increased rCBF) vermis and cerebellar hemispheres in first two paired scans and anterior cingulate and vermis on the final pair. Increased rCBF at rest occurred in cerebellar hemispheres, vermis, and right dorsomedial frontal cortex. These preliminary observations suggest that there may be a role of the hindbrain (vermis and cerebellum) with HANDLE treatment of chronic TBI.

  9. Vapour explosions (fuel-coolant interactions) resulting from the sub-surface injection of water into molten metals: preliminary results

    International Nuclear Information System (INIS)

    Asher, R.C.; Bullen, D.; Davies, D.

    1976-03-01

    Preliminary experiments are reported on the relationship between the injection mode of contact and the occurrence and magnitude of vapour explosions. Water was injected beneath the surface of molten metals, chiefly tin at 250 to 900 0 C. Vapour explosions occurred in many, but not all, cases. The results are compared with Dullforce's observations (Culham Report (CLM-P424) on the dropping mode of contact and it appears that rather different behaviour is found; in particular, the present results suggest that the Temperature Interaction Zone is different for the two modes of contact. (author)

  10. A Qualitative Study of Factors Influencing Racial Diversity in Environmental Education: Preliminary Results

    Science.gov (United States)

    Kathy James; Leo H. McAvoy

    1992-01-01

    This study presents preliminary result interviews with people of color working in environmental education and interpretation throughout the United States. The three primary questions asked were these? (1) What path led each individual to a career in environmental education; (2) How does each individual define environmentalism? and (3) What are the primary issues this...

  11. Radiation Testing on State-of-the-Art CMOS: Challenges, Plans, and Preliminary Results

    Science.gov (United States)

    LaBel, Kenneth A.; Cohn, Lewis M.

    2009-01-01

    At GOMAC 2007 and 2008, we discussed a variety of challenges for radiation testing of modern semiconductor devices and technologies [1, 2]. In this presentation, we provide more specific details in this on-going investigation focusing on out-of-the-box lessons observed for providing radiation effects assurances as well as preliminary test results.

  12. An algorithm for longitudinal registration of PET/CT images acquired during neoadjuvant chemotherapy in breast cancer: preliminary results.

    Science.gov (United States)

    Li, Xia; Abramson, Richard G; Arlinghaus, Lori R; Chakravarthy, Anuradha Bapsi; Abramson, Vandana; Mayer, Ingrid; Farley, Jaime; Delbeke, Dominique; Yankeelov, Thomas E

    2012-11-16

    .044), respectively (p = 0.005). The results indicate that the constrained ABA algorithm can accurately align prone breast FDG-PET images acquired at different time points while keeping the tumor from being substantially compressed or distorted. NCT00474604.

  13. A coupled mechanical-hydrological investigation of crystalline rocks: Annual technical progress report, proposed test matrix, and preliminary results

    International Nuclear Information System (INIS)

    Bastian, R.J.; Voss, C.F.; Apted, M.J.; Shotwell, L.R.

    1988-02-01

    This report reviews the Fracture Flow Behavior in Rock Study being performed at the Pacific Northwest Laboratory. The study's objective is to determine the feasibility of predicting mechanical-hydrological behavior of natural rock fractures by accurately characterizing fracture surface topography and mineralization. A laboratory-scale facility is currently being used to ensure optimum control of variables. Devising a technique to study small-scale samples is the first step to understanding the complex coupled processes encountered in geomechanics and hydrology. The major accomplishments during fiscal year 1987 were initial development of the innovative testing method, identification of appropriate specimens, substantial renovation to the facility, completion of several sets of experiments, and procurement of hardware components for a laser-imaging device used to characterize fracture surfaces. A complete set of preliminary results and findings is presented in this report. These results, gathered from a basalt core with a natural fracture, have demonstrated that the methodology is valid, and definite trends in the data are readily apparent. 10 refs., 14 figs., 1 tab

  14. Correlation of ultrasound imaging of oral swallow with ventilatory alterations in cerebral palsied and normal children: preliminary observations.

    Science.gov (United States)

    Kenny, D J; Casas, M J; McPherson, K A

    1989-01-01

    Preliminary results of an investigation that synchronizes the videotaped output of ultrasound camera and the analog data from physiological measurements of swallowing and ventilation in normal and cerebral palsied (CP) children are presented. Four cerebral palsied children and three control children undertook a single sip-swallow of 5 ml of liquid and a solid mastication-swallow sequence on three occasions according to a defined protocol. The CP children exhibited much more variability and less control of the liquid bolus than did the controls. The ultrasound image clearly demonstrates the lack of control of the posterior of the tongue in many CP children. Some parts of the sequence of oral swallow and the time to achieve maximum anterior displacement of the hyoid bone appear to be slowed. The sequential events of swallowing show less variability as the sip-swallow proceeds from the oral voluntary to pharyngeal and lower involuntary phases. This study also identified a short-latency apnea that appears to accompany a saliva (protective) swallow and a long-latency apnea that accompanies semi-solid or liquid bolus (alimentary) swallows. Further investigations of normal and CP children utilizing a combined diagnostic imaging-physiological measurement approach will follow this initial study.

  15. Chemical Analysis of the Moon at the Surveyor VI Landing Site: Preliminary Results.

    Science.gov (United States)

    Turkevich, A L; Patterson, J H; Franzgrote, E J

    1968-06-07

    The alpha-scattering experiment aboard soft-landing Surveyor VI has provided a chemical analysis of the surface of the moon in Sinus Medii. The preliminary results indicate that, within experimental errors, the composition is the same as that found by Surveyor V in Mare Tranquillitatis. This finding suggests that large portions of the lunar maria resemble basalt in composition.

  16. Small-angle neutron scattering investigations of Co-doped iron oxide nanoparticles. Preliminary results

    Science.gov (United States)

    Creanga, Dorina; Balasoiu, Maria; Soloviov, Dmitro; Balasoiu-Gaina, Alexandra-Maria; Puscasu, Emil; Lupu, Nicoleta; Stan, Cristina

    2018-03-01

    Preliminary small-angle neutron scattering investigations on aqueous suspensions of several cobalt doped ferrites (CoxFe3-xO4, x=0; 0.5; 1) nanoparticles prepared by chemical co-precipitation method, are reported. The measurements were accomplished at the YuMO instrument in function at the IBR-2 reactor. Results of intermediary data treatment are presented and discussed.

  17. Preliminary results of a battery-based, multi megawatt 200 kA pulsed power supply.

    NARCIS (Netherlands)

    Karthaus, W.; Kolkert, W.J.; Nowee, J.

    1989-01-01

    A pulsed power supply consisting of a fast discharge battery, a switch based on silicon-controlled-rectifier SCR technology, and an energy storage/pulse transformer is discussed. Preliminary results indicate that the battery is capable of discharging current pulses with reproducible peak values of

  18. 78 FR 28192 - Polyethylene Retail Carrier Bags From Thailand: Preliminary Results of Antidumping Duty...

    Science.gov (United States)

    2013-05-14

    ... Bags From Thailand: Preliminary Results of Antidumping Duty Administrative Review; 2011-2012 AGENCY... on polyethylene retail carrier bags (PRCBs) from Thailand. The review covers 11 respondents. The... merchandise has been sold at less than normal value by the companies subject to this review. DATES: Effective...

  19. Framework for 3D histologic reconstruction and fusion with in vivo MRI: Preliminary results of characterizing pulmonary inflammation in a mouse model

    Energy Technology Data Exchange (ETDEWEB)

    Rusu, Mirabela, E-mail: mirabela.rusu@gmail.com; Wang, Haibo; Madabhushi, Anant [Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio 44106 (United States); Golden, Thea; Gow, Andrew [Department of Pharmacology and Toxicology, Rutgers University, Piscataway, New Jersey 08854 (United States)

    2015-08-15

    Purpose: Pulmonary inflammation is associated with a variety of diseases. Assessing pulmonary inflammation on in vivo imaging may facilitate the early detection and treatment of lung diseases. Although routinely used in thoracic imaging, computed tomography has thus far not been compellingly shown to characterize inflammation in vivo. Alternatively, magnetic resonance imaging (MRI) is a nonionizing radiation technique to better visualize and characterize pulmonary tissue. Prior to routine adoption of MRI for early characterization of inflammation in humans, a rigorous and quantitative characterization of the utility of MRI to identify inflammation is required. Such characterization may be achieved by considering ex vivo histology as the ground truth, since it enables the definitive spatial assessment of inflammation. In this study, the authors introduce a novel framework to integrate 2D histology, ex vivo and in vivo imaging to enable the mapping of the extent of disease from ex vivo histology onto in vivo imaging, with the goal of facilitating computerized feature analysis and interrogation of disease appearance on in vivo imaging. The authors’ framework was evaluated in a preclinical preliminary study aimed to identify computer extracted features on in vivo MRI associated with chronic pulmonary inflammation. Methods: The authors’ image analytics framework first involves reconstructing the histologic volume in 3D from individual histology slices. Second, the authors map the disease ground truth onto in vivo MRI via coregistration with 3D histology using the ex vivo lung MRI as a conduit. Finally, computerized feature analysis of the disease extent is performed to identify candidate in vivo imaging signatures of disease presence and extent. Results: The authors evaluated the framework by assessing the quality of the 3D histology reconstruction and the histology—MRI fusion, in the context of an initial use case involving characterization of chronic

  20. Framework for 3D histologic reconstruction and fusion with in vivo MRI: Preliminary results of characterizing pulmonary inflammation in a mouse model

    International Nuclear Information System (INIS)

    Rusu, Mirabela; Wang, Haibo; Madabhushi, Anant; Golden, Thea; Gow, Andrew

    2015-01-01

    Purpose: Pulmonary inflammation is associated with a variety of diseases. Assessing pulmonary inflammation on in vivo imaging may facilitate the early detection and treatment of lung diseases. Although routinely used in thoracic imaging, computed tomography has thus far not been compellingly shown to characterize inflammation in vivo. Alternatively, magnetic resonance imaging (MRI) is a nonionizing radiation technique to better visualize and characterize pulmonary tissue. Prior to routine adoption of MRI for early characterization of inflammation in humans, a rigorous and quantitative characterization of the utility of MRI to identify inflammation is required. Such characterization may be achieved by considering ex vivo histology as the ground truth, since it enables the definitive spatial assessment of inflammation. In this study, the authors introduce a novel framework to integrate 2D histology, ex vivo and in vivo imaging to enable the mapping of the extent of disease from ex vivo histology onto in vivo imaging, with the goal of facilitating computerized feature analysis and interrogation of disease appearance on in vivo imaging. The authors’ framework was evaluated in a preclinical preliminary study aimed to identify computer extracted features on in vivo MRI associated with chronic pulmonary inflammation. Methods: The authors’ image analytics framework first involves reconstructing the histologic volume in 3D from individual histology slices. Second, the authors map the disease ground truth onto in vivo MRI via coregistration with 3D histology using the ex vivo lung MRI as a conduit. Finally, computerized feature analysis of the disease extent is performed to identify candidate in vivo imaging signatures of disease presence and extent. Results: The authors evaluated the framework by assessing the quality of the 3D histology reconstruction and the histology—MRI fusion, in the context of an initial use case involving characterization of chronic

  1. Image processing on the image with pixel noise bits removed

    Science.gov (United States)

    Chuang, Keh-Shih; Wu, Christine

    1992-06-01

    Our previous studies used statistical methods to assess the noise level in digital images of various radiological modalities. We separated the pixel data into signal bits and noise bits and demonstrated visually that the removal of the noise bits does not affect the image quality. In this paper we apply image enhancement techniques on noise-bits-removed images and demonstrate that the removal of noise bits has no effect on the image property. The image processing techniques used are gray-level look up table transformation, Sobel edge detector, and 3-D surface display. Preliminary results show no noticeable difference between original image and noise bits removed image using look up table operation and Sobel edge enhancement. There is a slight enhancement of the slicing artifact in the 3-D surface display of the noise bits removed image.

  2. Shigaraki UAV-Radar Experiment (ShUREX): overview of the campaign with some preliminary results

    Science.gov (United States)

    Kantha, Lakshmi; Lawrence, Dale; Luce, Hubert; Hashiguchi, Hiroyuki; Tsuda, Toshitaka; Wilson, Richard; Mixa, Tyler; Yabuki, Masanori

    2017-12-01

    The Shigaraki unmanned aerial vehicle (UAV)-Radar Experiment (ShUREX) is an international (USA-Japan-France) observational campaign, whose overarching goal is to demonstrate the utility of small, lightweight, inexpensive, autonomous UAVs in probing and monitoring the lower troposphere and to promote synergistic use of UAVs and very high frequency (VHF) radars. The 2-week campaign lasting from June 1 to June 14, 2015, was carried out at the Middle and Upper Atmosphere (MU) Observatory in Shigaraki, Japan. During the campaign, the DataHawk UAV, developed at the University of Colorado, Boulder, and equipped with high-frequency response cold wire and pitot tube sensors (as well as an iMET radiosonde), was flown near and over the VHF-band MU radar. Measurements in the atmospheric column in the immediate vicinity of the radar were obtained. Simultaneous and continuous operation of the radar in range imaging mode enabled fine-scale structures in the atmosphere to be visualized by the radar. It also permitted the UAV to be commanded to sample interesting structures, guided in near real time by the radar images. This overview provides a description of the ShUREX campaign and some interesting but preliminary results of the very first simultaneous and intensive probing of turbulent structures by UAVs and the MU radar. The campaign demonstrated the validity and utility of the radar range imaging technique in obtaining very high vertical resolution ( 20 m) images of echo power in the atmospheric column, which display evolving fine-scale atmospheric structures in unprecedented detail. The campaign also permitted for the very first time the evaluation of the consistency of turbulent kinetic energy dissipation rates in turbulent structures inferred from the spectral broadening of the backscattered radar signal and direct, in situ measurements by the high-frequency response velocity sensor on the UAV. The data also enabled other turbulence parameters such as the temperature

  3. Scintigraphic test of gastric emptying and motility: preliminary results in patients with chronic gastritis

    International Nuclear Information System (INIS)

    Hausmann, T.; Mueller-Schauenburg, W.; Goeke, M.; Luebeck, M.; Gratz, K.F.; Meier, P.; Manns, M.; Hundeshagen, H.

    1995-01-01

    To record gastric peristalsis using a conventional scintigraphic gastric emptying test the frame rate was increased to 1 frame per 3 s at 10, 30, and 50 min postprandially. The gastric contraction frequency was obtained from the first harmonic of a Fourier transform of a gastric region of interest (ROI) curve. The propagation of gastric contractions was better revealed from computed functional images of the phase and amplitude distribution as compared with the multiple scintigraphic images. The maximal count-rate changes per pixel were calculated as an estimate of the most prominent regional contractile activity of the gastric wall. Among 12 patients with chronic gastritis the group with more severe dyspeptic complaints (n = 6) had significantly higher count-rate changes per pixel when compared with the group with minor complaints (20.0, 21.1 and 14.2 vs 12.9, 12.0, and 10.4 counts/pixel X s at 10, 30, and 50 min. respectively; p < 0.05). The mean half-times of gastric emptying (61, SD 11 vs 54, SD 13 min) and the mean gastric contraction frequencies (2.99, SD 0.19; 3.09, SD 0.33; 3.07, SD 0.10 vs 3.15, SD 0.15; 3.17, SD 0.13; 3.23, SD 0.20 cycles/min at 10, 30, and 50 min, respectively) did not show significant differences between both groups. Our preliminary results agree with the hypothesis of the occurrence of more powerful, nonexpulsive gastric-wall contractions in patients with more severe dyspeptic complaints. Hence, additional quantification of gastric motility allowed a more detailed evaluation of gastric-motor-activity disorders that were for so long not accessible to conventional gastric-emptying tests. (orig.)

  4. Scintigraphic test of gastric emptying and motility: preliminary results in patients with chronic gastritis

    Energy Technology Data Exchange (ETDEWEB)

    Hausmann, T. [Abt. Nuklearmedizin und Spezielle Biophysik, Medizinische Hochschule Hannover (Germany); Mueller-Schauenburg, W. [Abt. Nuklearmedizin, Univ. Tuebingen (Germany); Goeke, M. [Abt. Gastroenterologie und Hepatologie, Medizinische Hochschule Hannover (Germany); Luebeck, M. [Abt. Nuklearmedizin, Univ.-Krankenhaus Eppendorf, Hamburg (Germany); Gratz, K.F. [Abt. Nuklearmedizin und Spezielle Biophysik, Medizinische Hochschule Hannover (Germany); Meier, P. [Abt. Gastroenterologie und Hepatologie, Medizinische Hochschule Hannover (Germany); Manns, M. [Abt. Gastroenterologie und Hepatologie, Medizinische Hochschule Hannover (Germany); Hundeshagen, H. [Abt. Nuklearmedizin und Spezielle Biophysik, Medizinische Hochschule Hannover (Germany)

    1995-11-01

    To record gastric peristalsis using a conventional scintigraphic gastric emptying test the frame rate was increased to 1 frame per 3 s at 10, 30, and 50 min postprandially. The gastric contraction frequency was obtained from the first harmonic of a Fourier transform of a gastric region of interest (ROI) curve. The propagation of gastric contractions was better revealed from computed functional images of the phase and amplitude distribution as compared with the multiple scintigraphic images. The maximal count-rate changes per pixel were calculated as an estimate of the most prominent regional contractile activity of the gastric wall. Among 12 patients with chronic gastritis the group with more severe dyspeptic complaints (n = 6) had significantly higher count-rate changes per pixel when compared with the group with minor complaints (20.0, 21.1 and 14.2 vs 12.9, 12.0, and 10.4 counts/pixel X s at 10, 30, and 50 min. respectively; p < 0.05). The mean half-times of gastric emptying (61, SD 11 vs 54, SD 13 min) and the mean gastric contraction frequencies (2.99, SD 0.19; 3.09, SD 0.33; 3.07, SD 0.10 vs 3.15, SD 0.15; 3.17, SD 0.13; 3.23, SD 0.20 cycles/min at 10, 30, and 50 min, respectively) did not show significant differences between both groups. Our preliminary results agree with the hypothesis of the occurrence of more powerful, nonexpulsive gastric-wall contractions in patients with more severe dyspeptic complaints. Hence, additional quantification of gastric motility allowed a more detailed evaluation of gastric-motor-activity disorders that were for so long not accessible to conventional gastric-emptying tests. (orig.)

  5. A Preliminary Comparison of Three Dimensional Particle Tracking and Sizing using Plenoptic Imaging and Digital In-line Holography

    Energy Technology Data Exchange (ETDEWEB)

    Guildenbecher, Daniel Robert; Munz, Elise Dahnke; Farias, Paul Abraham; Thurow, Brian S [Auburn U

    2015-12-01

    Digital in-line holography and plenoptic photography are two techniques for single-shot, volumetric measurement of 3D particle fields. Here we present a preliminary comparison of the two methods by applying plenoptic imaging to experimental configurations that have been previously investigated with digital in-line holography. These experiments include the tracking of secondary droplets from the impact of a water drop on a thin film of water and tracking of pellets from a shotgun. Both plenoptic imaging and digital in-line holography successfully quantify the 3D nature of these particle fields. This includes measurement of the 3D particle position, individual particle sizes, and three-component velocity vectors. For the initial processing methods presented here, both techniques give out-of-plane positional accuracy of approximately 1-2 particle diameters. For a fixed image sensor, digital holography achieves higher effective in-plane spatial resolutions. However, collimated and coherent illumination makes holography susceptible to image distortion through index of refraction gradients, as demonstrated in the shotgun experiments. On the other hand, plenotpic imaging allows for a simpler experimental configuration. Furthermore, due to the use of diffuse, white-light illumination, plenoptic imaging is less susceptible to image distortion in the shotgun experiments. Additional work is needed to better quantify sources of uncertainty, particularly in the plenoptic experiments, as well as develop data processing methodologies optimized for the plenoptic measurement.

  6. High Resolution Mineral Mapping of the Oman Drilling Project Cores with Imaging Spectroscopy: Preliminary Results

    Science.gov (United States)

    Greenberger, R. N.; Ehlmann, B. L.; Kelemen, P. B.; Manning, C. E.; Teagle, D. A. H.; Harris, M.; Michibayashi, K.; Takazawa, E.

    2017-12-01

    The Oman Drilling Project provides an unprecedented opportunity to study the formation and alteration of oceanic crust and peridotite. Key to answering the main questions of the project are a characterization of the primary and secondary minerals present within the drill core and their spatial relationships. To that end, we used the Caltech imaging spectrometer system to scan the entire 1.5-km archive half of the core from all four gabbro and listvenite boreholes (GT1A, GT2A, GT3A, and BT1B) at 250 µm/pixel aboard the JAMSTEC Drilling Vessel Chikyu during the ChikyuOman core description campaign. The instrument measures the visible and shortwave infrared reflectance spectra of the rocks as a function of wavelength from 0.4 to 2.6 µm. This wavelength range is sensitive to many mineral groups, including hydrated minerals (phyllosilicates, zeolites, amorphous silica polytypes), carbonates, sulfates, and transition metals, most commonly iron-bearing mineralogies. To complete the measurements, the core was illuminated with a halogen light source and moved below the spectrometer at 1 cm/s by the Chikyu's Geotek track. Data are corrected and processed to reflectance using measurements of dark current and a spectralon calibration panel. The data provide a unique view of the mineralogy at high spatial resolution. Analysis of the images for complete downhole trends is ongoing. Thus far, a variety of minerals have been identified within their petrologic contexts, including but not limited to magnesite, dolomite, calcite, quartz (through an Si-OH absorption due to minor H2O), serpentine, chlorite, epidote, zeolites, mica (fuchsite), kaolinite, prehnite, gypsum, amphibole, and iron oxides. Further analysis will likely identify more minerals. Results include rapidly distinguishing the cations present within carbonate minerals and identifying minerals of volumetrically-low abundance within the matrix and veins of core samples. This technique, for example, accurately identifies

  7. Technical aspects of quality assurance in mammography: Preliminary results from Serbia

    Directory of Open Access Journals (Sweden)

    Živković Monika M.

    2010-01-01

    Full Text Available Mammography is the method of choice for early detection of breast cancer. In Serbia, mammography is performed only clinically, although there is a plan to introduce mammography as a screening method. Currently, there are 60 mammographic units in practice, resulting in 70 000 mammographies annually. The survey was conducted in order to investigate mammographic practice in Serbia, identify weak points and suggest appropriate corrective measures. Basic technical parameters of the X-ray tube and generator, processing, image quality, and patient doses in 20 mammographic units were studied. The survey demonstrated considerable variations in technical parameters that affect image quality, and patients doses. Patient dose levels, in terms of the mean glandular dose, were fairly consistent with current European reference levels: 1.8 (0.40-4.3 mGy. However, due to inappropriate image receptors, image processing and viewing conditions and automatic exposure control adjustment, suboptimal image quality was a common finding. Simple improvements of the radiographic technique and maintenance procedure, along with the rigid implementation of the quality control procedure and training of the operating staff, would improve the performance levels of mammographic practice in Serbia, i. e. result in the production of high quality images with a reasonably low radiation risk to patients.

  8. Approach to the fracture hydrology at Stripa: preliminary results

    International Nuclear Information System (INIS)

    Gale, J.E.; Witherspoon, P.A.

    1979-05-01

    There are two main problems associated with the concept of geologic storage of radioactive waste in fractured crystalline rock: (1) the thermo-mechanical effects of the heat generated by the waste, and (2) the potential for transport of radioactive materials by the groundwater system. In both problems, fractures play a dominant role. An assessment of the hydraulic and mechanical characteristics of fractued rock requires a careful series of laboratory and field investigations. The complexity of the problem is illustrated by the field studies in a fractured granite that are currently underway in an abandoned iron-ore mine at Stripa, Sweden. Much information is being gathered from an extensive series of boreholes and fracture maps. The approach being taken to integrate these data into an analysis of the fracture hydrology is reviewed and preliminary results from the hydrology program are presented. 13 figures

  9. Monte Carlo simulation of a TRIGA source driven core configuration: Preliminary results

    International Nuclear Information System (INIS)

    Burgio, N.; Ciavola, C.; Santagata, A.

    2002-01-01

    The different core configurations with a k eff ranging from 0.93 to 0.98, and their response when driven by a pulsed neutron source were simulated with MCNP4C3 (Los Alamos - Monte Carlo N Particles). Simulation results could be considered both as preliminary check for nuclear data and a conceptual design for 'source jerk' experiments on the frame of TRIGA Accelerator Driven Experiment (TRADE) on the reactor facility of Casaccia research center. (author)

  10. Functional MR imaging at 1.5 T. Initial results using photic and motoric stimulation

    DEFF Research Database (Denmark)

    Henriksen, O; Larsson, H B; Ring, P

    1993-01-01

    A preliminary investigation of the effects of stimulation of the visual and the motor cortex was made on a conventional 1.5 T MR imaging scanner. Both types of activation gave a detectable change in the signal between rest and stimulation using a gradient echo sequence with an echo time of 60 ms....... The observed effects were assumed to be caused by variation in the amount of paramagnetic deoxyhemoglobin between stimulation and rest due to local increase of capillary blood flow in the human brain during stimulation....

  11. Functional MR imaging at 1.5 T. Initial results using photic and motoric stimulation

    DEFF Research Database (Denmark)

    Henriksen, O; Larsson, H B; Ring, P

    1993-01-01

    A preliminary investigation of the effects of stimulation of the visual and the motor cortex was made on a conventional 1.5 T MR imaging scanner. Both types of activation gave a detectable change in the signal between rest and stimulation using a gradient echo sequence with an echo time of 60 ms........ The observed effects were assumed to be caused by variation in the amount of paramagnetic deoxyhemoglobin between stimulation and rest due to local increase of capillary blood flow in the human brain during stimulation....

  12. Ultrasound imaging with a micromotor; Micromotor ni yoru choonpa imaging

    Energy Technology Data Exchange (ETDEWEB)

    Oshiro, O.; Salimuzzaman, M.; Matani, A.; Chihara, K. [Nara Institute of Science and Technology, Nara (Japan); Asao, M. [Osaka National Hospital, Osaka (Japan)

    1998-03-01

    This paper describes a new ultrasound intravascular imaging system. In this system, an ultrasound probe consists of a micromotor, an ultrasound reflecting mirror attached with the micromotor and an ultrasound transducer. Ultrasound is scanned radially by a micromotor instead of a rotation transmitting wire and the rotation of the micromotor is performed and controlled by an external magnetic field. This ultrasound imaging system with a micromotor was applied to observe the inside of blood vessels through in vitro experiments. The preliminary results suggest that this system has the sufficient ability to define the blood vessel morphology and that the simple image processing enhances signal-to-noise ratio of the reconstructed image. 12 refs., 5 figs.

  13. Hyperpolarized 3He magnetic resonance imaging: Preliminary evaluation of phenotyping potential in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Mathew, Lindsay; Kirby, Miranda; Etemad-Rezai, Roya; Wheatley, Andrew; McCormack, David G.; Parraga, Grace

    2011-01-01

    Rationale and objectives: Emphysema and small airway obstruction are the pathological hallmarks of chronic obstructive pulmonary disease (COPD). The aim of this pilot study in a small group of chronic obstructive pulmonary disease (COPD) patients was to quantify hyperpolarized helium-3 ( 3 He) magnetic resonance imaging (MRI) functional and structural measurements and to explore the potential role for 3 He MRI in detecting the lung structural and functional COPD phenotypes. Materials and methods: We evaluated 20 ex-smokers with stage I (n = 1), stage II (n = 9) and stage III COPD (n = 10). All subjects underwent same-day plethysmography, spirometry, 1 H MRI and hyperpolarized 3 He MRI at 3.0 T. 3 He ventilation defect percent (VDP) was generated from 3 He static ventilation images and 1 H thoracic images and the 3 He apparent diffusion coefficient (ADC) was derived from diffusion-weighted MRI. Results: Based on the relative contribution of normalized ADC and VDP, there was evidence of a predominant 3 He MRI measurement in seven patients (n = 3 mainly ventilation defects or VDP dominant (VD), n = 4 mainly increased ADC or ADC dominant (AD)). Analysis of variance (ANOVA) showed significantly lower ADC for subjects with predominantly elevated VDP (p = 0.02 compared to subjects with predominantly elevated ADC; p = 0.008 compared to mixed group) and significantly decreased VDP for subjects with predominantly elevated ADC (p = 0.003, compared to mixed group). Conclusion: In this small pilot study, a preliminary analysis shows the potential for 3 He MRI to categorize or phenotype COPD ex-smokers, providing good evidence of feasibility for larger prospective studies.

  14. Preliminary results of a feasibility study for a hard x-ray Kirkpatrick-Baez telescope

    DEFF Research Database (Denmark)

    Joensen, Karsten D.; Gorenstein, Paul; Wood, James L.

    1994-01-01

    the preliminary results of a feasibility study of a multifocus Kirkpatrick-Baez telescope. We conclude that high quality multilayers can be performed on relevant thin large flat substrate with adequate uniformity, and that existing deposition chambers can produce the multilayers at a rate of 0.42 m2 per day, so...

  15. Nuclear Reactor Component Code CUPID-I: Numerical Scheme and Preliminary Assessment Results

    International Nuclear Information System (INIS)

    Cho, Hyoung Kyu; Jeong, Jae Jun; Park, Ik Kyu; Kim, Jong Tae; Yoon, Han Young

    2007-12-01

    A component scale thermal hydraulic analysis code, CUPID (Component Unstructured Program for Interfacial Dynamics), is being developed for the analysis of components of a nuclear reactor, such as reactor vessel, steam generator, containment, etc. It adopted three-dimensional, transient, two phase and three-field model. In order to develop the numerical schemes for the three-field model, various numerical schemes have been examined including the SMAC, semi-implicit ICE, SIMPLE, Row Scheme and so on. Among them, the ICE scheme for the three-field model was presented in the present report. The CUPID code is utilizing unstructured mesh for the simulation of complicated geometries of the nuclear reactor components. The conventional ICE scheme that was applied to RELAP5 and COBRA-TF, therefore, were modified for the application to the unstructured mesh. Preliminary calculations for the unstructured semi-implicit ICE scheme have been conducted for a verification of the numerical method from a qualitative point of view. The preliminary calculation results showed that the present numerical scheme is robust and efficient for the prediction of phase changes and flow transitions due to a boiling and a flashing. These calculation results also showed the strong coupling between the pressure and void fraction changes. Thus, it is believed that the semi-implicit ICE scheme can be utilized for transient two-phase flows in a component of a nuclear reactor

  16. Nuclear Reactor Component Code CUPID-I: Numerical Scheme and Preliminary Assessment Results

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Hyoung Kyu; Jeong, Jae Jun; Park, Ik Kyu; Kim, Jong Tae; Yoon, Han Young

    2007-12-15

    A component scale thermal hydraulic analysis code, CUPID (Component Unstructured Program for Interfacial Dynamics), is being developed for the analysis of components of a nuclear reactor, such as reactor vessel, steam generator, containment, etc. It adopted three-dimensional, transient, two phase and three-field model. In order to develop the numerical schemes for the three-field model, various numerical schemes have been examined including the SMAC, semi-implicit ICE, SIMPLE, Row Scheme and so on. Among them, the ICE scheme for the three-field model was presented in the present report. The CUPID code is utilizing unstructured mesh for the simulation of complicated geometries of the nuclear reactor components. The conventional ICE scheme that was applied to RELAP5 and COBRA-TF, therefore, were modified for the application to the unstructured mesh. Preliminary calculations for the unstructured semi-implicit ICE scheme have been conducted for a verification of the numerical method from a qualitative point of view. The preliminary calculation results showed that the present numerical scheme is robust and efficient for the prediction of phase changes and flow transitions due to a boiling and a flashing. These calculation results also showed the strong coupling between the pressure and void fraction changes. Thus, it is believed that the semi-implicit ICE scheme can be utilized for transient two-phase flows in a component of a nuclear reactor.

  17. Recent results from the DELPHI barrel ring imaging Cherenkov counter

    International Nuclear Information System (INIS)

    Anassontzis, E.G.; Ioannou, P.; Kalkanis, G.; Katsanevas, S.; Kontaxis, I.; Kourkoumelis, C.; Nounos, S.; Preve, P.; Resvanis, L.K.; Brunet, J.M.; Dolbeau, J.; Guglielmo, L.; Ledroit, F.; Poutot, D.; Tristram, G.

    1991-01-01

    The DELPHI detector, installed at LEP, is equipped with RICH (Ring Imaging Cherenkov) counters. The Barrel part incorporates a liquid (C 6 F 14 ) and a gaseous (C 5 F 12 ) radiator providing particle identification up to 20GeV/c. The Cherenkov protons of both radiators are detected by TPC-like photon detectors. The drift gas (75% CH 4 + 25% C 2 H 6 ) is doped with TMAE, but which the UV Cherenkov photons are converted into single free photo-electrons. These are drifted towards MWPC's at the end of the drift tubes and the space coordinates of the conversion point are determined. One half of the Barrel RICH is now equipped with drift tubes and has provided results from the liquid radiator since spring 1990. The gas radiator has been tested with C 2 F 6 as a preliminary filling since August 1990. The data obtained demonstrate the good particle identification potential. For the liquid radiator the number of detected photons per ring in hadron jets is N=8, whereas for muon pairs (single tracks) N=10 has been obtained. For the gas radiator 2.1 photons per track were observed, which demonstrates the good functioning of the focussing mirrors, as the C 2 F 6 this is close to the expected value

  18. SPANISH MULTICENTRIC STUDY ABOUT NUTRITION-INFLAMATIONhn WITH MID DILUTION (ENIMID STUDY: PRELIMINARY RESULTS

    Directory of Open Access Journals (Sweden)

    Barril G

    2012-06-01

    CONCLUSIONS: 1-The preliminary results show that MidDilution provides a good removal of small and middle molecules, increases appetite by providing a proper balance of cytokines through stimulation of antiinflamatory ones and neuropeptide Y. 2-It provides an improvement of body composition. Finally MidDilution improves nutritional parameters which leads to a better quality of life, as well as physical and mental status.

  19. Preliminary results from the Orbiting Solar Observatory 8 - Observations of optically thin lines

    Science.gov (United States)

    Shine, R. A.; Roussel-Dupre, D.; Bruner, E. C., Jr.; Chipman, E. G.; Lites, B. W.; Rottman, G. J.; Athay, R. G.; White, O. R.

    1976-01-01

    The University of Colorado spectrometer aboard OSO 8 has measured the high temperature C IV resonance lines (at 1548 and 1551 A) and the Si IV resonance lines (at 1393 and 1402 A) formed in the solar chromosphere-corona transition region. Preliminary results include studies of mean profiles, a comparison of cell and network profiles, and the behavior of the lines at the extreme solar limb.

  20. Preliminary results from a study of the double beta decay of 150Nd

    International Nuclear Information System (INIS)

    Perillo, I.M.C.; Chan, Y.D.; Hurley, D.; Lesko, K.T.; McDonald, R.J.; Moorhead, M.E.; Norman, E.B.; Smith, A.R.; Stokstad, R.G.

    1996-01-01

    We report the preliminary results from a study of the double beta decay of 150 Nd to the first 0 + excited state of 150 Sm. Our data consists of 50 days of counting 5 kg of natural Nd 2 O 3 at the LBNL-Oroville low background facility. The deduced lower limit for the half life of this decay mode is 4.9.10 19 years. (orig.)

  1. 76 FR 26247 - Magnesium Metal From the Russian Federation: Preliminary Results of Antidumping Duty...

    Science.gov (United States)

    2011-05-06

    ... to represent the total net realizable value (NRV) of raw magnesium, it used this value as the offset... AVISMA did not make sales to the United States at less than normal value. If these preliminary results... Than Fair Value: Pure Magnesium in Granular Form From the People's Republic of China, 66 FR 49345...

  2. Emergency CT brain: preliminary interpretation with a tablet device: image quality and diagnostic performance of the Apple iPad.

    LENUS (Irish Health Repository)

    Mc Laughlin, Patrick

    2012-04-01

    Tablet devices have recently been used in radiological image interpretation because they have a display resolution comparable to desktop LCD monitors. We identified a need to examine tablet display performance prior to their use in preliminary interpretation of radiological images. We compared the spatial and contrast resolution of a commercially available tablet display with a diagnostic grade 2 megapixel monochrome LCD using a contrast detail phantom. We also recorded reporting discrepancies, using the ACR RADPEER system, between preliminary interpretation of 100 emergency CT brain examinations on the tablet display and formal review on a diagnostic LCD. The iPad display performed inferiorly to the diagnostic monochrome display without the ability to zoom. When the software zoom function was enabled on the tablet device, comparable contrast detail phantom scores of 163 vs 165 points were achieved. No reporting discrepancies were encountered during the interpretation of 43 normal examinations and five cases of acute intracranial hemorrhage. There were seven RADPEER2 (understandable) misses when using the iPad display and 12 with the diagnostic LCD. Use of software zoom in the tablet device improved its contrast detail phantom score. The tablet allowed satisfactory identification of acute CT brain findings, but additional research will be required to examine the cause of "understandable" reporting discrepancies that occur when using tablet devices.

  3. MRI of the wrist at 7 tesla using an eight-channel array coil combined with parallel imaging: preliminary results.

    Science.gov (United States)

    Chang, Gregory; Friedrich, Klaus M; Wang, Ligong; Vieira, Renata L R; Schweitzer, Mark E; Recht, Michael P; Wiggins, Graham C; Regatte, Ravinder R

    2010-03-01

    To determine the feasibility of performing MRI of the wrist at 7 Tesla (T) with parallel imaging and to evaluate how acceleration factors (AF) affect signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and image quality. This study had institutional review board approval. A four-transmit eight-receive channel array coil was constructed in-house. Nine healthy subjects were scanned on a 7T whole-body MR scanner. Coronal and axial images of cartilage and trabecular bone micro-architecture (3D-Fast Low Angle Shot (FLASH) with and without fat suppression, repetition time/echo time = 20 ms/4.5 ms, flip angle = 10 degrees , 0.169-0.195 x 0.169-0.195 mm, 0.5-1 mm slice thickness) were obtained with AF 1, 2, 3, 4. T1-weighted fast spin-echo (FSE), proton density-weighted FSE, and multiple-echo data image combination (MEDIC) sequences were also performed. SNR and CNR were measured. Three musculoskeletal radiologists rated image quality. Linear correlation analysis and paired t-tests were performed. At higher AF, SNR and CNR decreased linearly for cartilage, muscle, and trabecular bone (r < -0.98). At AF 4, reductions in SNR/CNR were:52%/60% (cartilage), 72%/63% (muscle), 45%/50% (trabecular bone). Radiologists scored images with AF 1 and 2 as near-excellent, AF 3 as good-to-excellent (P = 0.075), and AF 4 as average-to-good (P = 0.11). It is feasible to perform high resolution 7T MRI of the wrist with parallel imaging. SNR and CNR decrease with higher AF, but image quality remains above-average.

  4. Knowledge-based low-level image analysis for computer vision systems

    Science.gov (United States)

    Dhawan, Atam P.; Baxi, Himanshu; Ranganath, M. V.

    1988-01-01

    Two algorithms for entry-level image analysis and preliminary segmentation are proposed which are flexible enough to incorporate local properties of the image. The first algorithm involves pyramid-based multiresolution processing and a strategy to define and use interlevel and intralevel link strengths. The second algorithm, which is designed for selected window processing, extracts regions adaptively using local histograms. The preliminary segmentation and a set of features are employed as the input to an efficient rule-based low-level analysis system, resulting in suboptimal meaningful segmentation.

  5. Annotating images by mining image search results

    NARCIS (Netherlands)

    Wang, X.J.; Zhang, L.; Li, X.; Ma, W.Y.

    2008-01-01

    Although it has been studied for years by the computer vision and machine learning communities, image annotation is still far from practical. In this paper, we propose a novel attempt at model-free image annotation, which is a data-driven approach that annotates images by mining their search

  6. Adaptive sound speed correction for abdominal ultrasonography: preliminary results

    Science.gov (United States)

    Jin, Sungmin; Kang, Jeeun; Song, Tai-Kyung; Yoo, Yangmo

    2013-03-01

    Ultrasonography has been conducting a critical role in assessing abdominal disorders due to its noninvasive, real-time, low cost, and deep penetrating capabilities. However, for imaging obese patients with a thick fat layer, it is challenging to achieve appropriate image quality with a conventional beamforming (CON) method due to phase aberration caused by the difference between sound speeds (e.g., 1580 and 1450m/s for liver and fat, respectively). For this, various sound speed correction (SSC) methods that estimate the accumulated sound speed for a region-of interest (ROI) have been previously proposed. However, with the SSC methods, the improvement in image quality was limited only for a specific depth of ROI. In this paper, we present the adaptive sound speed correction (ASSC) method, which can enhance the image quality for whole depths by using estimated sound speeds from two different depths in the lower layer. Since these accumulated sound speeds contain the respective contributions of layers, an optimal sound speed for each depth can be estimated by solving contribution equations. To evaluate the proposed method, the phantom study was conducted with pre-beamformed radio-frequency (RF) data acquired with a SonixTouch research package (Ultrasonix Corp., Canada) with linear and convex probes from the gel pad-stacked tissue mimicking phantom (Parker Lab. Inc., USA and Model539, ATS, USA) whose sound speeds are 1610 and 1450m/s, respectively. From the study, compared to the CON and SSC methods, the ASSC method showed the improved spatial resolution and information entropy contrast (IEC) for convex and linear array transducers, respectively. These results indicate that the ASSC method can be applied for enhancing image quality when imaging obese patients in abdominal ultrasonography.

  7. Finite-element model evaluation of barrier configurations to reduce infiltration into waste-disposal structures: preliminary results and design considerations

    International Nuclear Information System (INIS)

    Lu, A.H.; Phillips, S.J.; Adams, M.R.

    1982-09-01

    Barriers to reduce infiltration into waste burial disposal structures (trenches, pits, etc.) may be required to provide adequate waste confinement. The preliminary engineering design of these barriers should consider interrelated barrier performance factors. This paper summarizes preliminary computer simulation activities to further engineering barrier design efforts. Several barrier configurations were conceived and evaluated. Models were simulated for each barrier configuration using a finite element computer code. Results of this preliminary evaluation indicate that barrier configurations, depending on their morphology and materials, may significantly influence infiltration, flux, drainage, and storage of water through and within waste disposal structures. 9 figures

  8. The evaluation of GL impact in Physical sciences using bibliometric indicators : preliminary results

    OpenAIRE

    Di Cesare, Rosa (CNR); GreyNet, Grey Literature Network Service

    1994-01-01

    A bibliometric study of the Italian grey literature in SIGLE database. Preliminary results. Given the increasing importance of Grey Literature (GL) for the information and documentation field, it is essential to apply a bibliometric analysis similar to the one widely used for the conventional literature. Study objectives: 1) impact evalutation of grey literature in physical sciences; and 2) differentiation between scientific and non scientific grey literature documents in the same discipline,...

  9. 78 FR 7395 - Stainless Steel Bar From India: Preliminary Results of Antidumping Duty Administrative Review...

    Science.gov (United States)

    2013-02-01

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-533-810] Stainless Steel Bar From... steel bar (SSB) from India. The period of review (POR) is February 1, 2011, through January 31, 2012... Preliminary Results of Antidumping Duty Administrative Review: Stainless Steel Bar from India'' dated...

  10. Simulation of an image network in a medical image information system

    International Nuclear Information System (INIS)

    Massar, A.D.A.; De Valk, J.P.J.; Reijns, G.L.; Bakker, A.R.

    1985-01-01

    The desirability of an integrated (digital) communication system for medical images is widely accepted. In the USA and in Europe several experimental projects are in progress to realize (a part of) such a system. Among these is the IMAGIS project in the Netherlands. From the conclusions of the preliminary studies performed, some requirements can be formulated such a system should meet in order to be accepted by its users. For example, the storage resolution of the images should match the maximum resolution of the presently acquired digital images. This determines the amount of data and therefore the storage requirements. Further, the desired images should be there when needed. This time constraint determines the speed requirements to be imposed on the system. As compared to current standards, very large storage capacities and very fast communication media are needed to meet these requirements. By employing cacheing techniques and suitable data compression schemes for the storage and by carefully choosing the network protocols, bare capacity demands can be alleviated. A communication network is needed to make the imaging system available over a larger area. As the network is very likely to become a major bottleneck for system performance, effects of variation of various attributes have to be carefully studied and analysed. After interesting results had been obtained (although preliminary) using a simulation model for a layered storage structure, it was decided to apply simulation also to this problem. Effects of network topology, access protocols and buffering strategies will be tested. Changes in performance resulting from changes in various network parameters will be studied. Results of this study at its present state are presented

  11. Imaging autofluorescence temporal signatures of the human ocular fundus in vivo

    Science.gov (United States)

    Papour, Asael; Taylor, Zachary; Stafsudd, Oscar; Tsui, Irena; Grundfest, Warren

    2015-11-01

    We demonstrate real-time in vivo fundus imaging capabilities of our fluorescence lifetime imaging technology for the first time. This implementation of lifetime imaging uses light emitting diodes to capture full-field images capable of showing direct tissue contrast without executing curve fitting or lifetime calculations. Preliminary results of fundus images are presented, investigating autofluorescence imaging potential of various retina biomarkers for early detection of macular diseases.

  12. Preliminary experimental results from a linear reciprocating magnetic refrigerator prototype

    International Nuclear Information System (INIS)

    Tagliafico, Luca Antonio; Scarpa, Federico; Valsuani, Federico; Tagliafico, Giulio

    2013-01-01

    A linear reciprocating magnetic refrigerator prototype was designed and built with the aid of an industrial partner. The refrigerator is based on the Active Magnetic Regenerative cycle, and exploits two regenerators working in parallel. The active material is Gadolinium in plates, 0.8 mm thick, for a total mass of 0.36 kg. The device is described and results about magnetic field and temperature span measurements are presented. The designed permanent magnet structure, based on an improved cross-type arrangement, generates a maximum magnetic field intensity of 1.55 T in air, over a gap of (13 × 50 × 100) mm 3 . The maximum temperature span achieved is 5.0 K, in a free run condition. -- Highlights: ► We give preliminary results from a linear reciprocating magnetic refrigerator prototype. ► The design is intended to process visualization and investigation. ► The prototype behavior gives us various suggestions to improve its general performance

  13. CATE 2016 Indonesia: normalized radial graded filtering, site-to-site image registration, and preliminary results

    Science.gov (United States)

    Jensen, L.; Kovac, S. A.; Hare, H. S.; Mitchell, A. M.; McKay, M. A.; Bosh, R.; Watson, Z.; Penn, M.

    2016-12-01

    An area of the solar corona from 1 out to approximately 2.5 solar radii is currently poorly sampled in astronomy. This is largely due to difficulties inherent in observing the sun from space and from the ground. Specifically focusing on ground based observations, the main problem is scattered light in the Earth's atmosphere and in the telescopes themselves. A total solar eclipse solves this problem by blocking the light from the photosphere of the sun before it enters the atmosphere, reducing the scattered light in the atmosphere by a factor of 10,000. However, using a total solar eclipse introduces another challenge due to the small window of time it provides. At any given location in 2017, the totality will last for only about 2.5 minutes and such a small data set limits the studies that can be done on the inner corona. The Citizen Continental-America Telescopic Eclipse Experiment plans to overcome this issue by taking advantage of America's infrastructure and using 60 identical telescopes to collect continuous data of the solar eclipse as the shadow travels from Oregon to South Carolina. By splicing these data together 90 minutes of one-of-a-kind data can be collected, revealing the dynamics of the inner corona as never seen before. For the 2016 Indonesian total solar eclipse the CATE project collected data using 5 sites along the eclipse path. These data were then used to develop processing programs to use on future data. These processes included site-to-site image registration as well as normalized radial graded filtering of the images. Programs were also developed to begin performing studies on the data including overlapping CATE and LASCO space telescope data for a total coronal image as well as thread tracing routines to quantify direction in the coronal filaments. This work was made possible through the National Solar Observatory Research Experiences for Undergraduates (REU) Program, which is funded by the National Science Foundation (NSF). The NSO

  14. In vivo 31P MR spectroscopy of breast tumors: preliminary results

    International Nuclear Information System (INIS)

    Choe, Bo Young; Kim, Hak Hee; Suh, Tae Suk; Shinn, Kyung Sub; Jung, Sang Seol

    1995-01-01

    To evaluate the various phosphorus metabolism of breast tumors with use of in vivo phosphorus-31 ( 31 P) MR spectroscopy (MRS). Five patients with breast tumor (benign in two, malignant in three) and three normal healthy volunteers participated in this study. All in vivo 31 P MRS examinations were performed on 1.5T whole-body MRI/MRS system by using a Free Induction Decay (FID) pulse sequence. T1-weighted MR images were used for localization of tumors. Peak areas for each phosphorus metabolite were measured using a Marquart algorithm. Breast carcinoma had a substantially larger phosphomonoester (PME) and a smaller phosphocreatine (PCr) peak intensity than normal breast tissue. This was reflected in the relatively higher PME/PCr ratio of breast carcinomas as well as phosphodiester (PDE)/PCr, inorganic phosphate (Pi)/PCr, and adenosine triphosphate (ATP)/PCr ratios, compared with normal controls. The mean pH value of breast tumor demonstrating the alkaline nature was higher than that of normal controls. Spectral patterns between benign breast disease and normal breast tissue were quite similar, and differentiation was not established. Our preliminary study suggests that in vivo 31 P MRS is a noninvasive examination which may be useful in the early differentiation of malignant breast tumors from normal and benign conditions. However, normal control and benign conditions could not be characterized on the basis of the phosphorus metabolite ratios

  15. Preliminary results on the cryogenic target for FIREX project

    International Nuclear Information System (INIS)

    Iwamoto, A.; Maekawa, R.; Mito, T.; Okamoto, M.; Motojima, O.; Nakai, M.; Norimatsu, T.; Nagai, K.

    2006-01-01

    Preliminary tests on the cryogenic target for the fast ignition realization experiment (FIREX) project has been conducted. A foam shell method is proposed to realize its target design. A foam target consists of three parts: a foam shell, a conical laser guide and a liquid or gas feeder made of glass. The shell is a hollow sphere (500 μm in diameter) with a uniform and thin foam layer (about 20 μm in thickness). Epoxy resin is utilized to assemble the parts into the target. Liquid fuel is fed into the shell by the feeder and is soaked up by the foam material through capillarity. The fuel is then solidified. Regarding target fabrication, one of the concerns is the influence on various thermal contractions from the different materials when it is cooled down to cryogenic environment. This paper describes the result on the validity check at cryogenic environment and the demonstration of H 2 liquefaction using a dummy target instead of the foam target. Judging from these results, the target assembled in the same process as the dummy target is sure to be practicable for the FIREX project. (authors)

  16. Image denoising by exploring external and internal correlations.

    Science.gov (United States)

    Yue, Huanjing; Sun, Xiaoyan; Yang, Jingyu; Wu, Feng

    2015-06-01

    Single image denoising suffers from limited data collection within a noisy image. In this paper, we propose a novel image denoising scheme, which explores both internal and external correlations with the help of web images. For each noisy patch, we build internal and external data cubes by finding similar patches from the noisy and web images, respectively. We then propose reducing noise by a two-stage strategy using different filtering approaches. In the first stage, since the noisy patch may lead to inaccurate patch selection, we propose a graph based optimization method to improve patch matching accuracy in external denoising. The internal denoising is frequency truncation on internal cubes. By combining the internal and external denoising patches, we obtain a preliminary denoising result. In the second stage, we propose reducing noise by filtering of external and internal cubes, respectively, on transform domain. In this stage, the preliminary denoising result not only enhances the patch matching accuracy but also provides reliable estimates of filtering parameters. The final denoising image is obtained by fusing the external and internal filtering results. Experimental results show that our method constantly outperforms state-of-the-art denoising schemes in both subjective and objective quality measurements, e.g., it achieves >2 dB gain compared with BM3D at a wide range of noise levels.

  17. WISE/NEOWISE OBSERVATIONS OF THE JOVIAN TROJANS: PRELIMINARY RESULTS

    International Nuclear Information System (INIS)

    Grav, T.; Mainzer, A. K.; Bauer, J.; Masiero, J.; Eisenhardt, P. R. M.; Blauvelt, E.; DeBaun, E.; Elsbury, D.; Gautier, T. IV; Gomillion, S.; Hand, E.; Wilkins, A.; Spahr, T.; McMillan, R. S.; Walker, R.; Cutri, R.; Wright, E.

    2011-01-01

    We present the preliminary analysis of over 1739 known and 349 candidate Jovian Trojans observed by the NEOWISE component of the Wide-field Infrared Survey Explorer (WISE). With this survey the available diameters, albedos, and beaming parameters for the Jovian Trojans have been increased by more than an order of magnitude compared to previous surveys. We find that the Jovian Trojan population is very homogenous for sizes larger than ∼10 km (close to the detection limit of WISE for these objects). The observed sample consists almost exclusively of low albedo objects, having a mean albedo value of 0.07 ± 0.03. The beaming parameter was also derived for a large fraction of the observed sample, and it is also very homogenous with an observed mean value of 0.88 ± 0.13. Preliminary debiasing of the survey shows that our observed sample is consistent with the leading cloud containing more objects than the trailing cloud. We estimate the fraction to be N(leading)/N(trailing) ∼ 1.4 ± 0.2, lower than the 1.6 ± 0.1 value derived by Szabó et al.

  18. Assessment of liver steatosis in chicken by using acoustic radiation force impulse imaging: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Guzman Aroca, Florentina; Serrano, Laura; Berna-Serna, Juan D.; Reus, Manuel [Virgen de la Arrixaca University Hospital, Department of Radiology, El Palmar, Murcia (Spain); Ayala, Ignacio [University of Murcia, Department of Animal Medicine and Surgery, Murcia (Spain); Castell, Maria T. [University of Murcia, Department of Cell Biology, Murcia (Spain); Garcia-Perez, Bartolome [Virgen de la Arrixaca University Hospital, Internal Medicine Service, El Palmar, Murcia (Spain)

    2010-10-15

    To evaluate acoustic radiation force impulse (ARFI) imaging as a non-invasive tool for quantification of the grades of liver steatosis in chickens. We used two different diets: a standard diet (SD group) and a hyperlipidaemic diet (HD group). The ARFI technique was performed in all the animals in the right hepatic lobe and shear wave velocity (SWV) was measured and expressed in metres per second (m/s). Plasma lipid levels were analysed. Steatosis was quantified by using semiquantitative analysis. Statistical analysis was used and Pearson's correlation coefficient was calculated. Mean SWV was 0.94 {+-} 0.16 m/s (range 0.8-1.3 m/s) in the SD group and 1.91 {+-} 0.25 m/s (range 1.3-2.2 m/s) in the HD group (p < 0.001). The lowest SWVs ({<=}1.3 m/s) corresponded to the chickens in the SD group, with 100% of the animals returning a score of 0, whereas the range of SWV in the HD group chickens was between 1.6 and 2.2 m/s. A substantial correlation was observed between SWVs with histological semiquantitative analysis of steatosis (r = 0.85, p < 0.001). ARFI imaging is a non-invasive diagnostic tool that allows discrimination between the grades of liver steatosis in chickens. (orig.)

  19. Assessment of liver steatosis in chicken by using acoustic radiation force impulse imaging: preliminary results

    International Nuclear Information System (INIS)

    Guzman Aroca, Florentina; Serrano, Laura; Berna-Serna, Juan D.; Reus, Manuel; Ayala, Ignacio; Castell, Maria T.; Garcia-Perez, Bartolome

    2010-01-01

    To evaluate acoustic radiation force impulse (ARFI) imaging as a non-invasive tool for quantification of the grades of liver steatosis in chickens. We used two different diets: a standard diet (SD group) and a hyperlipidaemic diet (HD group). The ARFI technique was performed in all the animals in the right hepatic lobe and shear wave velocity (SWV) was measured and expressed in metres per second (m/s). Plasma lipid levels were analysed. Steatosis was quantified by using semiquantitative analysis. Statistical analysis was used and Pearson's correlation coefficient was calculated. Mean SWV was 0.94 ± 0.16 m/s (range 0.8-1.3 m/s) in the SD group and 1.91 ± 0.25 m/s (range 1.3-2.2 m/s) in the HD group (p < 0.001). The lowest SWVs (≤1.3 m/s) corresponded to the chickens in the SD group, with 100% of the animals returning a score of 0, whereas the range of SWV in the HD group chickens was between 1.6 and 2.2 m/s. A substantial correlation was observed between SWVs with histological semiquantitative analysis of steatosis (r = 0.85, p < 0.001). ARFI imaging is a non-invasive diagnostic tool that allows discrimination between the grades of liver steatosis in chickens. (orig.)

  20. FTY720-loaded poly(DL-lactide-co-glycolide) electrospun scaffold significantly increases microvessel density over 7 days in streptozotocin-induced diabetic C57b16/J mice: preliminary results.

    Science.gov (United States)

    Bowers, D T; Chhabra, P; Langman, L; Botchwey, E A; Brayman, K L

    2011-11-01

    Nanofiber scaffolds could improve islet transplant success by physically mimicking the shape of extracellular matrix and by acting as a drug-delivery vehicle. Scaffolds implanted in alternate transplant sites must be prevascularized or very quickly vascularized following transplantation to prevent hypoxia-induced islet necrosis. The local release of the S1P prodrug FTY720 induces diameter enlargement and increases in length density. The objective of this preliminary study was to evaluate length and diameter differences between diabetic and nondiabetic animals implanted with FTY720-containing electrospun scaffolds using intravital imaging of dorsal skinfold window chambers. Electrospun mats of randomly oriented fibers we created from polymer solutions of PLAGA (50:50 LA:GA) with and without FTY720 loaded at a ratio of 1:200 (FTY720:PLAGA by wt). The implanted fiber mats were 4 mm in diameter and ∼0.2 mm thick. Increases in length density and vessel diameter were assessed by automated analysis of images over 7 days in RAVE, a Matlab program. Image analysis of repeated measures of microvessel metrics demonstrated a significant increase in the length density from day 0 to day 7 in the moderately diabetic animals of this preliminary study (P < .05). Furthermore, significant differences in length density at day 0 and day 3 were found between recently STZ-induced moderately diabetic and nondiabetic animals in response to FTY720 local release (P < .05, Student t test). Driving the islet revascularization process using local release of factors, such as FTY720, from biodegradable polymers makes an attractive system for the improvement of islet transplant success. Preliminary study results suggest that a recently induced moderately diabetic state may potentiate the mechanism by which local release of FTY720 from polymer fibers increases length density of microvessels. Therefore, local release of S1P receptor-targeted drugs is under further investigation for improvement of

  1. Preliminary results of the PREFER FP7 Project

    Science.gov (United States)

    Fusilli, Lorenzo; Laneve, Giovanni; De Bonis, Roberto; Sebastian, Ana; Ferrucci, Fabrizio; Oliveira, Sandra

    2014-05-01

    The need to improve the information and intelligence support for forest fire prevention is widely recognized. Fire prevention is still the most cost-effective strategy when compared to firefighting and extinguishing that are costly, local, and triggered only in response to already ongoing crises. PREFER project, funded under the EU FP7 (G.A. 312931), intends to contribute at responding to such a pragmatic need of southern Europe's forests by: providing timely information products based on the exploitation of all available spacecraft sensors, offering a portfolio of products focused on pre- and post-crisis forest fire emergency, suitable for the users in the different countries of the European Mediterranean area. The PREFER Service portfolio consists of two main services: 1. Information Support to Fire Preparedness/Prevention Phase" (ISP) Service 2. Information Support to Fire Recovery/Reconstruction Phase" (ISR) Service This service is already at an advanced stage having completed the first year of activity. During this time several products have been consolidated: seasonal fuel maps; daily and seasonal fire hazard maps; seasonal risk maps; prescribed fire maps. This paper aims at presenting the preliminary results of the research activity carried out in the framework of the PREFER project, focusing, in particular, on these recalled above. As for Fire Risk and Hazard assessment, many indexes have been developed in the last years. Hardly any of them uses data derived from satellite images. The FPI index is an exception to this rule which, in addition, makes use of meteorological data. In spite of being a very complete index, the FPI still allows room for improvement which justify the interest of PREFER in it. PREFER's innovative approach to FPI will allow taking into account the effect of solar illumination conditions in determining the humidity present in the dead vegetation, and therefore its proneness to burn. PREFER innovation also focus in allowing the index to

  2. Preliminary results on ocean dynamics from Skylab and their implications for future spacecraft

    Science.gov (United States)

    Hayes, J.; Pierson, W. J.; Cardone, V. J.

    1975-01-01

    The instrument aboard Skylab designated S193 - a combined passive and active microwave radar system acting as a radiometer, scatterometer, and altimeter - is used to measure the surface vector wind speeds in the planetary boundary layer over the oceans. Preliminary results corroborate the hypothesis that sea surface winds in the planetary boundary layer can be determined from satellite data. Future spacecraft plans for measuring a geoid with an accuracy up to 10 cm are discussed.

  3. Towards distortion-free robust image authentication

    International Nuclear Information System (INIS)

    Coltuc, D

    2007-01-01

    This paper investigates a general framework for distortion-free robust image authentication by multiple marking. First, by robust watermarking a subsampled version of image edges is embedded. Then, by reversible watermarking the information needed to recover the original image is inserted, too. The hiding capacity of the reversible watermarking is the essential requirement for this approach. Thus in case of no attacks not only image is authenticated but also the original is exactly recovered. In case of attacks, reversibility is lost, but image can still be authenticated. Preliminary results providing very good robustness against JPEG compression are presented

  4. Combining semantic technologies with a content-based image retrieval system - Preliminary considerations

    Science.gov (United States)

    Chmiel, P.; Ganzha, M.; Jaworska, T.; Paprzycki, M.

    2017-10-01

    Nowadays, as a part of systematic growth of volume, and variety, of information that can be found on the Internet, we observe also dramatic increase in sizes of available image collections. There are many ways to help users browsing / selecting images of interest. One of popular approaches are Content-Based Image Retrieval (CBIR) systems, which allow users to search for images that match their interests, expressed in the form of images (query by example). However, we believe that image search and retrieval could take advantage of semantic technologies. We have decided to test this hypothesis. Specifically, on the basis of knowledge captured in the CBIR, we have developed a domain ontology of residential real estate (detached houses, in particular). This allows us to semantically represent each image (and its constitutive architectural elements) represented within the CBIR. The proposed ontology was extended to capture not only the elements resulting from image segmentation, but also "spatial relations" between them. As a result, a new approach to querying the image database (semantic querying) has materialized, thus extending capabilities of the developed system.

  5. 78 FR 32367 - Multilayered Wood Flooring From the People's Republic of China; Preliminary Results of...

    Science.gov (United States)

    2013-05-30

    ... From the People's Republic of China; Preliminary Results of Antidumping Duty New Shipper Review; 2011... duty order on multilayered wood flooring (``MLWF'') from the People's Republic of China (``PRC''). The period of review (``POR'') is May 26, 2011 through May 31, 2012. The review covers one exporter of...

  6. Image Transmission Studies

    Science.gov (United States)

    Blaine, G. James; Hill, Rexford L.; Rueter, Allen P.; Senol, Evren; Studt, James W.

    1988-06-01

    Radiological PACS image sizes and desired retrieval response times demand high-bandwidth communication networks. Local area network technology at speeds higher that 10 Megabits/second (IEEE 802.3) have not achieved standardization nor production volume. Our current PACS experiments are based on a three-level subnet approach using 10 Mb/s Ethernet channels. An Ethernet channel is shown to support image transfers at an average throughput of 3 Mb/s. Preliminary measurements and simulation results suggest that traffic from as many as two-to-three archives can be supported on the same channel.

  7. Hyperpolarized {sup 3}He magnetic resonance imaging: Preliminary evaluation of phenotyping potential in chronic obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Mathew, Lindsay, E-mail: lmathew@imaging.robarts.ca [Imaging Research Laboratories, Robarts Research Institute, London (Canada); Department of Medical Biophysics, University of Western Ontario, London (Canada); Kirby, Miranda, E-mail: mkirby@imaging.robarts.ca [Imaging Research Laboratories, Robarts Research Institute, London (Canada); Department of Medical Biophysics, University of Western Ontario, London (Canada); Etemad-Rezai, Roya, E-mail: Roya.EtemadRezai@lhsc.on.ca [Department of Medical Imaging, University of Western Ontario (Canada); Wheatley, Andrew, E-mail: awheat@imaging.robarts.ca [Imaging Research Laboratories, Robarts Research Institute, London (Canada); McCormack, David G., E-mail: David.McCormack@lhsc.on.ca [Imaging Research Laboratories, Robarts Research Institute, London (Canada); Division of Respirology, Department of Medicine, University of Western Ontario, London (Canada); Lawson Health Research Institute, London (Canada); Parraga, Grace, E-mail: gep@imaging.robarts.ca [Imaging Research Laboratories, Robarts Research Institute, London (Canada); Department of Medical Biophysics, University of Western Ontario, London (Canada); Department of Medical Imaging, University of Western Ontario (Canada); Lawson Health Research Institute, London (Canada)

    2011-07-15

    Rationale and objectives: Emphysema and small airway obstruction are the pathological hallmarks of chronic obstructive pulmonary disease (COPD). The aim of this pilot study in a small group of chronic obstructive pulmonary disease (COPD) patients was to quantify hyperpolarized helium-3 ({sup 3}He) magnetic resonance imaging (MRI) functional and structural measurements and to explore the potential role for {sup 3}He MRI in detecting the lung structural and functional COPD phenotypes. Materials and methods: We evaluated 20 ex-smokers with stage I (n = 1), stage II (n = 9) and stage III COPD (n = 10). All subjects underwent same-day plethysmography, spirometry, {sup 1}H MRI and hyperpolarized {sup 3}He MRI at 3.0 T. {sup 3}He ventilation defect percent (VDP) was generated from {sup 3}He static ventilation images and {sup 1}H thoracic images and the {sup 3}He apparent diffusion coefficient (ADC) was derived from diffusion-weighted MRI. Results: Based on the relative contribution of normalized ADC and VDP, there was evidence of a predominant {sup 3}He MRI measurement in seven patients (n = 3 mainly ventilation defects or VDP dominant (VD), n = 4 mainly increased ADC or ADC dominant (AD)). Analysis of variance (ANOVA) showed significantly lower ADC for subjects with predominantly elevated VDP (p = 0.02 compared to subjects with predominantly elevated ADC; p = 0.008 compared to mixed group) and significantly decreased VDP for subjects with predominantly elevated ADC (p = 0.003, compared to mixed group). Conclusion: In this small pilot study, a preliminary analysis shows the potential for {sup 3}He MRI to categorize or phenotype COPD ex-smokers, providing good evidence of feasibility for larger prospective studies.

  8. Optical fiber sensors for image formation in radiodiagnostic - preliminary essays; Sensores a fibra optica para formacao de imagens em radiodiagnostico - ensaios preliminares

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Cesar C. de; Werneck, Marcelo M. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Biomedica

    1998-07-01

    This work describes preliminary experiments that will bring subsidies to analyze the capability to implement a system able to capture radiological images with new sensor system, comprised by FOs scanning process and I-CCD camera. These experiments have the main objective to analyze the optical response from FOs bundle, with several typos of scintillators associated with them, when it is submitted to medical x-rays exposition. (author)

  9. Preliminary study of image findings of femoroacetabular impingement

    International Nuclear Information System (INIS)

    Guo Zhe; Zhang Jing; Hong Nan; Cheng Xiaoguang

    2010-01-01

    Objective: To assess the image findings of femoroacetabular impingement (FAI). Methods: Image findings of 9 patients with surgically proved femoroacetabular impingement were retrospectively reviewed for characteristic image findings of FAI. All 9 patients underwent X-ray examinations and MRI of affected hip, and 1 patient underwent MR arthrography (MRA) additionally. Results: X-ray examinations of all 9 patients showed bump at femoral head-neck junction or overcoverage of the acetabular. MRI showed various degrees of injury of anterosuperior labrum in all 9 patients. The injuries were stage Ⅰ A in 2 cases, stage Ⅰ B in 3, stage Ⅱ A in 2, and stage Ⅱ B in 2. MRA of the case showed tears of anterosuperior labrum, with contrast media entering into the teared labrum. There were sclerosis and cystic degeneration of subchondral bone of femoral head in 2 cases, and these findings were confirmed as cartilage delamination by surgery. Conclusions: MRI can display the injures of labrum and articular cartilage, which is helpful to the early diagnosis of' FAI. (authors)

  10. Particle image velocimetry - Principles and first results

    International Nuclear Information System (INIS)

    Laporta, A.; Marechal, J.P.

    1997-01-01

    Particle Image Velocimetry (PIV) is a measurement technique elaborated towards the end of the 1970's, but which has developed considerably in recent years. The general principle of PIV is very simple and enables access to instantaneous velocity fields. It consists in recording images of tracer-particles injected into the flow and determining the distance covered by these particles. Since we know the time lapse between successive images of the same particle, we can derive the local fluid velocity. Among the many existing image acquisition and processing methods, the image inter-correlation analysis techniques, used with a pulsed laser source, is the most effective. Since we know the influence of different parameters (number of particles, beam power, time lapse between two successive images, size of query zones, etc.) on the quality of the final result, we can optimize practical adjustment of the PIV measurement scheme. The PIV was tested on the LAVITA hydraulic mockup (simulating the operation of a tangential fan). First results are, all in all, highly satisfactory. These have enabled the rapid drafting of instantaneous mean velocity field maps (20 images acquired in less than 90 seconds, with a post-processing time of about 10 minutes). Observation of the instantaneous fields has evidenced the presence of low frequency non-stationary phenomena which are not revealed by Laser Doppler Velocimetry (LDV). Quantitative comparison between LDV and PIV, concerning average fields, showed close results, with, however, local divergences which could be relatively marked. It must nevertheless be noted that the PIV measurements performed on LAVITA have not been optimized with a view to obtaining a consistently good accuracy level. Priority in the present case was given to the scope of the field explored, with a view to observing the large non-stationary structures within a flow. The PIV measurement technique is thus operational for prompt flow characterization. However

  11. Preliminary Results from Second Phase Sea Testing of the Wave Dragon Prototype Wave Energy Converter

    DEFF Research Database (Denmark)

    Soerensen, Hans Chr.; Tedd, James; Friis-Madsen, Erik

    2006-01-01

    In March 2006 the prototype Wave Dragon has been redeployed to a more energetic site in Nissum Bredning an inland sea in Western Denmark. This has followed a period of renovation of many aspects of the device which have resulted in 20% higher energy output. This paper describes the preliminary...

  12. Preliminary results of a program of quality assurance applied to the image service of a public hospital; Resultados preliminares de um programa de garantia de qualidade aplicado ao servico de imagem de um hospital publico

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Claudio Domingues de; Ferreira, Rubemar de Souza; Marechal, Maria Helena H. [Instituto de Radioprotecao e Dosimetria (IRD), Rio de Janeiro, RJ (Brazil); Milano, Nelly Ester [Hospital Municipal Cardoso Fontes, Rio de Janeiro, RJ (Brazil). Setor de Imagem

    2001-07-01

    Overall quality in radiological protection and medical image depend largely on keeping certain safety standards and technical procedures in good levels. In this way, in June 1998, the Ministry of Health published the document 453 - Guidelines of Radiological Protection to Medical and Dental Practices, defining different levels of actions and responsibility for radiological installation where the critical starting point was the necessity of a previous quality assurance program (QAP) into the radiological service. Preliminary results of a QAP realized in the Department of Radiology of a high complexity Hospital in Rio de Janeiro has showed that, although the importance of 453 Regulation be recognized, there is a few motivation for implementing it. Besides, during 1999 it was possible to identify film losses of 14,9 % related only to the repetition of exposures in the patients, reflecting in terms of cost about U$ 100,000 a year. Results suggest that losses of 64% of total film are due to under or over exposures and 15% are due to inadequate positioning of either film or patient, evidencing the need for training the technical and medical staff . (author)

  13. 76 FR 26241 - Polyethylene Retail Carrier Bags From Thailand: Extension of Time Limit for Preliminary Results...

    Science.gov (United States)

    2011-05-06

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-549-821] Polyethylene Retail Carrier Bags From Thailand: Extension of Time Limit for Preliminary Results of Antidumping Duty Administrative...) initiated an administrative review of the antidumping duty order on polyethylene retail carrier bags from...

  14. Improved cancer diagnostics by different image processing techniques on OCT images

    Science.gov (United States)

    Kanawade, Rajesh; Lengenfelder, Benjamin; Marini Menezes, Tassiana; Hohmann, Martin; Kopfinger, Stefan; Hohmann, Tim; Grabiec, Urszula; Klämpfl, Florian; Gonzales Menezes, Jean; Waldner, Maximilian; Schmidt, Michael

    2015-07-01

    Optical-coherence tomography (OCT) is a promising non-invasive, high-resolution imaging modality which can be used for cancer diagnosis and its therapeutic assessment. However, speckle noise makes detection of cancer boundaries and image segmentation problematic and unreliable. Therefore, to improve the image analysis for a precise cancer border detection, the performance of different image processing algorithms such as mean, median, hybrid median filter and rotational kernel transformation (RKT) for this task is investigated. This is done on OCT images acquired from an ex-vivo human cancerous mucosa and in vitro by using cultivated tumour applied on organotypical hippocampal slice cultures. The preliminary results confirm that the border between the healthy and the cancer lesions can be identified precisely. The obtained results are verified with fluorescence microscopy. This research can improve cancer diagnosis and the detection of borders between healthy and cancerous tissue. Thus, it could also reduce the number of biopsies required during screening endoscopy by providing better guidance to the physician.

  15. DETECTION OF Helicobacter pylori IN GASTRIC MUCOSA OF SHEEP: PRELIMINARY RESULTS

    Directory of Open Access Journals (Sweden)

    A. Rella

    2013-02-01

    Full Text Available Helicobacter pylori is an organism widespread in humans and sometimes responsible for serious illnesses. It has been hypothesized the existence of animal reservoirs, and that the infection route by H. pylori involves multiple pathways including food-borne transmission as the microorganism has been detected from sheep, goat and cow milk. This work reports the preliminary results of a survey conducted in order to investigate the presence of H. pylori in gastric mucosa of sheep slaughtered in Apulia region (Italy employing a Nested Polymerase Chain Reaction (Nested-PCR assay for the detection of the phosphoglucosamine mutase gene (glmM, as screening method followed by conventional bacteriological isolation. Out of the 50 gastric mucosa samples examined, 3 (6% resulted positive for the presence of glmMgene, but at this time no strains were isolated. The results deserve further investigations to asses the role of ruminants as possible reservoirs of H. pylori.

  16. Preliminary research results for parameter diagnostics of intense pulsed ion beams

    International Nuclear Information System (INIS)

    Yang Hailiang; Qiu Aici; Sun Jianfeng; He Xiaoping; Tang Junping; Wang Haiyang; Li Jingya; Ren Shuqing; Huang Jianjun; Zhang Jiasheng; Peng Jianchang; Ouyang Xiaoping; Zhang Guoguang; Li Hongyu

    2004-01-01

    The preliminary experimental results for parameter diagnostics of intense pulsed ion beams from the FLASH II accelerator were reported. The ion number of an intense pulsed ion beam were experimentally determined by monitoring delayed radioactivity from protons induced nuclear reactions in a 12 C target. The prompt γ-rays and diode Bremsstrahlung X-rays were measured with PIN semi-conductor detector and a ST401 plastic scintillator detector. The Bremsstrahlung distribution outside of the drift tube was detected with a thermoluminescent detector and the shielding design was also determined. The current densities of beam were measured with biased ion collector array. The ion beams were also recorded with a CR-39 detector. (author)

  17. Preliminary results in double cusp tandem mirror MM-4U

    International Nuclear Information System (INIS)

    Ming Linzhou; Tian Zhongyu; Feng Xiaozhen

    1990-10-01

    MM-4U device and preliminary experimental results are presented. Main results are as follows: The plasma has been produced by means of the injection of strong electron current; the axial profile of the plasma potential and the plasma electron density have been obtained respectively, they had a simular form; the plasma potential in the centre of the east cusp, the west cusp and the simple mirror; V e = -180V, V w = -164V, V m -1.8V; the electron density: n e = 1.7 x 10 11 cm -3 , n w = 4.7 x 10 10 cm -3 , n m = 7.5 x 10 7 cm -3 ; the electron temperature: T e = (19.9 ± 1.6) eV, T w = (20.7 ± 1.7) eV; the plasma pressure at 8 cm on the right of the west cusp centre is about 6.76 Pa, β ≅ 1.7 x 10 -3 . The plasma instability has been observed in the simple mirror, its vibration frequency was 7∼9.2 kHz. The results are discussed. The next new task of the physical experiment are proposed

  18. New large solar photocatalytic plant: set-up and preliminary results.

    Science.gov (United States)

    Malato, S; Blanco, J; Vidal, A; Fernández, P; Cáceres, J; Trincado, P; Oliveira, J C; Vincent, M

    2002-04-01

    A European industrial consortium called SOLARDETOX has been created as the result of an EC-DGXII BRITE-EURAM-III-financed project on solar photocatalytic detoxification of water. The project objective was to develop a simple, efficient and commercially competitive water-treatment technology, based on compound parabolic collectors (CPCs) solar collectors and TiO2 photocatalysis, to make possible easy design and installation. The design, set-up and preliminary results of the main project deliverable, the first European industrial solar detoxification treatment plant, is presented. This plant has been designed for the batch treatment of 2 m3 of water with a 100 m2 collector-aperture area and aqueous aerated suspensions of polycrystalline TiO2 irradiated by sunlight. Fully automatic control reduces operation and maintenance manpower. Plant behaviour has been compared (using dichloroacetic acid and cyanide at 50 mg l(-1) initial concentration as model compounds) with the small CPC pilot plants installed at the Plataforma Solar de Almería several years ago. The first results with high-content cyanide (1 g l(-1)) waste water are presented and plant treatment capacity is calculated.

  19. The effect of parental involvement in CBT of anxious children: Preliminary results from a RCT study

    DEFF Research Database (Denmark)

    Esbjørn, Barbara Hoff; Breinholst, Sonja; Reinholdt-Dunne, Marie Louise

    2011-01-01

    Esbjørn, B. H., Breinholst, S., Reinholdt-Dunne, M. L., & Leth, I. (2011). The effect of parental involvement in CBT of anxious children: Preliminary results from a RCT study. Poster accepted for the Association for Behavioral and Cognitive Therapies, Toronto, Canada....

  20. 75 FR 25207 - Polyethylene Retail Carrier Bags From Malaysia: Extension of Time Limit for Preliminary Results...

    Science.gov (United States)

    2010-05-07

    ... polyethylene retail carrier bags from Malaysia for the period August 1, 2008, through July 31, 2009. See... DEPARTMENT OF COMMERCE International Trade Administration A-557-813 Polyethylene Retail Carrier Bags From Malaysia: Extension of Time Limit for Preliminary Results of Antidumping Duty Administrative...

  1. Results of the Preliminary Test in the 1/4-Scale RCCS of the PMR200 VHTR

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong-Hwan; Bae, Yoon-Yeong; Hong, Sung-Deok; Kim, Chan-Soo; Cho, Bong-Hyun; Kim, Min-Hwan [Nuclear Hydrogen Reactor Technology Development Dep., Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    The Reactor Cavity Cooling System (RCCS) is a key ex-vessel passive safety system that will ensure the safety of the PMR200, and its performance needs to be verified. For the difficulty of the full-scale test, a 1/4-scale RCCS facility, NACEF (Natural Cooling Experimental Facility), has been constructed at KAERI, and a shakedown test has been performed. A brief design and the preliminary test results of this facility are described. A 1/4-scale RCCS mockup of PMR200, NACEF, was constructed and tested preliminarily. The functioning of the facility worked quite well. Moreover, the preliminary test results show a fairly good agreement with past work except for the conductive heat transfer region in the riser bottom. After a remedy such as the installation of more precise flow meters and a more improved insulation, the test facility is likely to work well.

  2. Precise Hypocenter Determination around Palu Koro Fault: a Preliminary Results

    Science.gov (United States)

    Fawzy Ismullah, M. Muhammad; Nugraha, Andri Dian; Ramdhan, Mohamad; Wandono

    2017-04-01

    Sulawesi area is located in complex tectonic pattern. High seismicity activity in the middle of Sulawesi is related to Palu Koro fault (PKF). In this study, we determined precise hypocenter around PKF by applying double-difference method. We attempt to investigate of the seismicity rate, geometry of the fault and distribution of focus depth around PKF. We first re-pick P-and S-wave arrival time of the PKF events to determine the initial hypocenter location using Hypoellipse method through updated 1-D seismic velocity. Later on, we relocated the earthquake event using double-difference method. Our preliminary results show the distribution of relocated events are located around PKF and have smaller residual time than the initial location. We will enhance the hypocenter location through updating of arrival time by applying waveform cross correlation method as input for double-difference relocation.

  3. Preliminary Results of the Louisiana Sex Offender Treatment Program

    OpenAIRE

    Lee A. Underwood; Frances L.L. Dailey; Carrie Merino; Yolanda Crump

    2015-01-01

    The purpose of this study was to offer preliminary support for the Louisiana Sex Offender Treatment Program (LSOTP) in addressing the needs of juvenile sex offenders. Research objectives were (1) to offer statistical evidence for reductions in anxiety, depression, cognitive distortion and negative attitudes towards women comparing a group of 21 adolescents, 12 of whom received services as usual and nine of whom participated in the LSOTP. A controlled experimental evaluation design was utilize...

  4. LOFAR: Recent Imaging Results and Future Prospects George ...

    Indian Academy of Sciences (India)

    and imaging software used for LOFAR image processing, we show some. 589 ... currently under heavy development. The software aspect of the LOFAR system ..... Telescope (ILT) foundation under a joint scientific policy. The results presented ...

  5. Experimental-demonstrative system for energy conversion using hydrogen fuel cell - preliminary results

    International Nuclear Information System (INIS)

    Stoenescu, D.; Stefanescu, I.; Patularu, I.; Culcer, M.; Lazar, R.E.; Carcadea, E.; Mirica, D. . E-mail address of corresponding author: daniela@icsi.ro; Stoenescu, D.)

    2005-01-01

    It is well known that hydrogen is the most promising solution of future energy, both for long and medium term strategies. Hydrogen can be produced using many primary sources (natural gas, methane, biomass, etc.), it can be burned or chemically react having a high yield of energy conversion, being a non-polluted fuel. This paper presents the preliminary results obtained by ICSI Rm. Valcea in an experimental-demonstrative conversion energy system made by a sequence of hydrogen purification units and a CO removing reactors until a CO level lower than 10ppm, that finally feeds a hydrogen fuel stack. (author)

  6. Head teacher professional networks in Italy: preliminary results of a national survey

    Directory of Open Access Journals (Sweden)

    Maurissens Isabel de

    2016-06-01

    Full Text Available In this article, we present the preliminary results of a national survey conducted by INDIRE on head teachers communities and professional networks. About one-fourth of the total population of Italian public school leaders participated in the survey. One of the main intents of this research is to contribute to understanding of the phenomenon of professional networks frequented by school leaders and to pave the way for a further reflection on how to use such networks for head teachers’ training so as to support their daily professional practice conducted too often in isolation.

  7. Design and preliminary results of a fuel flexible industrial gas turbine combustor

    Science.gov (United States)

    Novick, A. S.; Troth, D. L.; Yacobucci, H. G.

    1981-01-01

    The design characteristics are presented of a fuel tolerant variable geometry staged air combustor using regenerative/convective cooling. The rich/quench/lean variable geometry combustor is designed to achieve low NO(x) emission from fuels containing fuel bound nitrogen. The physical size of the combustor was calculated for a can-annular combustion system with associated operating conditions for the Allison 570-K engine. Preliminary test results indicate that the concept has the potential to meet emission requirements at maximum continuous power operation. However, airflow sealing and improved fuel/air mixing are necessary to meet Department of Energy program goals.

  8. Incorporating drug delivery into an imaging-driven, mechanics-coupled reaction diffusion model for predicting the response of breast cancer to neoadjuvant chemotherapy: theory and preliminary clinical results

    Science.gov (United States)

    Jarrett, Angela M.; Hormuth, David A.; Barnes, Stephanie L.; Feng, Xinzeng; Huang, Wei; Yankeelov, Thomas E.

    2018-05-01

    Clinical methods for assessing tumor response to therapy are largely rudimentary, monitoring only temporal changes in tumor size. Our goal is to predict the response of breast tumors to therapy using a mathematical model that utilizes magnetic resonance imaging (MRI) data obtained non-invasively from individual patients. We extended a previously established, mechanically coupled, reaction-diffusion model for predicting tumor response initialized with patient-specific diffusion weighted MRI (DW-MRI) data by including the effects of chemotherapy drug delivery, which is estimated using dynamic contrast-enhanced (DCE-) MRI data. The extended, drug incorporated, model is initialized using patient-specific DW-MRI and DCE-MRI data. Data sets from five breast cancer patients were used—obtained before, after one cycle, and at mid-point of neoadjuvant chemotherapy. The DCE-MRI data was used to estimate spatiotemporal variations in tumor perfusion with the extended Kety–Tofts model. The physiological parameters derived from DCE-MRI were used to model changes in delivery of therapy drugs within the tumor for incorporation in the extended model. We simulated the original model and the extended model in both 2D and 3D and compare the results for this five-patient cohort. Preliminary results show reductions in the error of model predicted tumor cellularity and size compared to the experimentally-measured results for the third MRI scan when therapy was incorporated. Comparing the two models for agreement between the predicted total cellularity and the calculated total cellularity (from the DW-MRI data) reveals an increased concordance correlation coefficient from 0.81 to 0.98 for the 2D analysis and 0.85 to 0.99 for the 3D analysis (p  <  0.01 for each) when the extended model was used in place of the original model. This study demonstrates the plausibility of using DCE-MRI data as a means to estimate drug delivery on a patient-specific basis in predictive models and

  9. Analysis of rainfall-induced shallow landslides in Jamne and Jaszcze stream valleys (Polish Carpathians – preliminary results

    Directory of Open Access Journals (Sweden)

    Zydroń Tymoteusz

    2016-03-01

    Full Text Available Analysis of rainfall-induced shallow landslides in Jamne and Jaszcze stream valleys (Polish Carpathians - preliminary results. Preliminary shallow landslide susceptibility mapping of the Jamne and Jaszcze stream valleys, located in the Polish Flysch Carpathians, is presented in the paper. For the purpose of mapping, there were used SINMAP and Iverson’s models integrating infiltration and slope stability calculations. The calibration of the used models parameters, obtained from limited field and laboratory tests, was performed using data from 8-9 July 1997, when as a consequence of a very intense rainfall, 94 shallow landslides were observed on meadows and arable lands. A comparison of the slope stability calculation results and the localisation of the noticed shallow landslides showed satisfactory agreement between localisation of the observed and computed unstable areas. However, it was concluded that better simulation results were obtained using Iverson’s model.

  10. 78 FR 2363 - Certain Cased Pencils From the People's Republic of China: Preliminary Results of Antidumping...

    Science.gov (United States)

    2013-01-11

    ... the People's Republic of China: Preliminary Results of Antidumping Duty Administrative Review and... Republic of China (``PRC''). The period of review (``POR'') is December 1, 2010, through November 30, 2011. The review covers one exporter of subject merchandise, Beijing Fila Dixon Stationery Company, Ltd. a...

  11. 78 FR 1834 - Magnesium Metal From the People's Republic of China: Preliminary Results of Antidumping Duty...

    Science.gov (United States)

    2013-01-09

    ... People's Republic of China: Preliminary Results of Antidumping Duty Administrative Review; 2011-2012... on magnesium metal from the People's Republic of China (``PRC''). The period of review (``POR'') is April 1, 2011, through March 31, 2012. This review covers one PRC company, Tianjin Magnesium...

  12. Fracture toughness of irradiated candidate materials for ITER first wall/blanket structures: Preliminary results

    International Nuclear Information System (INIS)

    Alexander, D.J.; Pawel, J.E.; Grossbeck, M.L.; Rowcliffe, A.F.

    1993-01-01

    Candidate materials for first wall/blanket structures in ITER have been irradiated to damage levels of about 3 dpa at temperatures of either 60 or 250 degrees C. Preliminary results have been obtained for several of these materials irradiated at 60 degrees C. The results show that irradiation at this temperature reduces the fracture toughness of austenitic stainless steels, but the toughness remains quite high. The unloading compliance technique developed for the subsize disk compact specimens works quite well, particularly for materials with lower toughness. Specimens of materials with very high toughness deform excessively, and this results in experimental difficulties

  13. Sealing a nuclear waste repository in Columbia river basalt: preliminary results

    International Nuclear Information System (INIS)

    Hodges, F.N.

    1980-01-01

    The long containment time required of repositories for nuclear waste (10 4 to 10 6 years) requires that materials used for repository seals be stable in the geologic environment of the repository and of proven longevity. A list of candidate materials for sealing a repository in Columbia River Basalts has been prepared and refined through laboratory testing. The most feasible techniques for emplacing preferred plug materials have been identified and the resultant plugs have been evaluated on the basis of design functions. Preconceptual designs for tunnel, shaft, and borehole seals consist of multiple zone plugs with each zone fulfilling one or more design functions. Zones of disturbed rock around tunnels and shafts, resulting from excavation and subsequent stress release, are zones of higher permeability and of possible fluid migration. In preliminary designs the disturbed zones are blocked by cut-off collars filled with low permeability materials

  14. Preliminary results on a 4 kJ, 140 k A plasma focus

    International Nuclear Information System (INIS)

    Silva, Patricio; Favre, Mario; Chuaqui, Hernan; Wyndham, Edmund

    1996-01-01

    Preliminary results on the operation of a 4 kJ, 140 kA Plasma Focus device are presented. The machine operates Hydrogen and Hydrogen-Argon mixtures at pressures between 400 m Torr to 10 Torr. Main diagnostics include electric and current measurements, time and space resolved X-ray observations, with limited spectral resolution, and B-dot sensors to monitor the evolution of de current sheet during the run up phase of the discharge. The results indicate that good focus is obtained in the above pressure range. This is inferred from I-dot traces and Pin diode and pin-hole camera X-ray observations. The B-dot loops suggest that a symmetric current sheet is produced. These results show that the machine exhibits a reliable performance, which allows further studies on dense transient plasmas to be developed. (author)

  15. Introducing handheld computing into a residency program: preliminary results from qualitative and quantitative inquiry.

    OpenAIRE

    Manning, B.; Gadd, C. S.

    2001-01-01

    Although published reports describe specific handheld computer applications in medical training, we know very little yet about how, and how well, handheld computing fits into the spectrum of information resources available for patient care and physician training. This paper reports preliminary quantitative and qualitative results from an evaluation study designed to track changes in computer usage patterns and computer-related attitudes before and after introduction of handheld computing. Pre...

  16. Energy dependent neutron imaging

    International Nuclear Information System (INIS)

    Kupperman, D.S.; Hitterman, R.L.; Rhodes, E.

    1990-01-01

    A waste package consisting of a container and high-level nuclear waste is being developed for the permanent disposal of radioactive waste. Yucca Mountain, Nevada, is being studied as a potential site for the underground high-level nuclear waste repository. A major consideration for choosing Yucca Mountain is the presence of zeolite in tertiary ash-flow tuffs. The presence of zeolites could provide geological barriers to radionuclide migration. The suitability of the tuffaceous rocks at Yucca Mountain for the repository is being investigated since the properties of the environment around a waste site must be well characterized to reliably predict performance. The results of experiments at Lawrence Livermore National Laboratory (LLNL) to assess the possibility of imaging water in Nevada Test Site welded tuff samples showed that nuclear magnetic resonance imaging is not viable. This leaves neutron tomography and high-frequency electromagnetic geotomography as possibilities for the practical imaging of distribution and flow of fluids in rock, including tuff specimens. Water tracers are needed in electromagnetic tomography techniques since the contrast for detecting water in cracks of tuff is lower than in granite because of the higher porosity in tuff. The results of preliminary testing with geotomography by LLNL indicates relatively low spatial resolution. More sensitive techniques for detecting water is needed. This paper describes preliminary experiments to apply pulsed neutrons to image water in a sample of tuff. 3 refs., 3 figs

  17. Design and preliminary assessment of 99mTc-labeled ultrasmall superparamagnetic iron oxide-conjugated bevacizumab for single photon emission computed tomography/magnetic resonance imaging of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Yanzhao Zhao; Hui Tan; Bing Wu; Pengcheng Hu; Pengyue Wu; Yushen Gu; Dengfeng Cheng; Hongcheng Shi; Qi Yao; Chunfu Zhang

    2014-01-01

    Hepatocellular carcinoma (HCC) has a very high incidence and mortality. Early diagnosis and timely treatments are therefore required to improve the quality of life and survival rate of HCC patients. Here, we developed a vascular endothelial growth factor (VEGF)-based multimodality imaging agent for single photon emission computed tomography (SPECT), computed tomography (CT) and magnetic resonance imaging (MRI) and used it to assess HCC mice and explore the combinative value of CT/MRI-based morphological imaging and SPECT functional imaging. HCC targeting with 125 I-labeled bevacizumab monoclonal antibody (mAb) was examined using SPECT/CT in HepG2 tumor-bearing mice after intravenous mAb injection. Based on this, an integrated, bimodal, VEGF-targeted, ultrasmall superparamagnetic iron oxide (USPIO)-conjugated 99m Tc-labeled bevacizumab mAb was synthesized to increase tumor penetration and accumulations. The in vivo pharmacokinetics and HepG2 tumor targeting were explored through in vivo planar imaging and SPECT/CT using a mouse model of HepG2 liver cancer. The specificity of the radiolabeled nanoparticles for HepG2 HCC was verified using in vitro immunohistochemistry and Prussian blue staining. With diethylenetriamine pentaacetic acid as a bifunctional chelating agent, USPIO-bevacizumab achieved a 99m Tc labeling efficiency of >90 %. The in vivo imaging results also exhibited the targeting of USPIO on HepG2 HCC. The specificity of these results was confirmed using in vitro immunohistochemistry and Prussian blue staining. Our preliminary findings showed the potential of USPIO as an imaging agent for the SPECT/MRI of HepG2 HCC. (author)

  18. Cherenkov ring imaging using a television digitizer

    International Nuclear Information System (INIS)

    Charpak, G.; Peisert, A.; Sauli, F.; Cavestro, A.; Vascon, M.; Zanella, G.

    1981-01-01

    A Cherenkov ring imaging device using as photon detector a multistep spark chamber coupled to a television digitizer is described. Results of a test run using triethylamine as photo-ionizing vapour are presented, as well as preliminary results obtained with a new vapour having an extremely low ionization potential. (orig.)

  19. 77 FR 73422 - Seamless Refined Copper Pipe and Tube From Mexico: Preliminary Results of Antidumping Duty...

    Science.gov (United States)

    2012-12-10

    ... Refined Copper Pipe and Tube From Mexico and the People's Republic of China: Antidumping Duty Orders and... and Tube From Mexico: Preliminary Results of Antidumping Duty Administrative Review; 2010-2011 AGENCY... on seamless refined copper pipe and tube from Mexico. The review covers two producers/ exporters of...

  20. 78 FR 6069 - Laminated Woven Sacks From the People's Republic of China: Preliminary Results of Antidumping...

    Science.gov (United States)

    2013-01-29

    ... the People's Republic of China: Preliminary Results of Antidumping Duty Administrative Review; 2011... antidumping duty order on laminated woven sacks (``sacks'') from the People's Republic of China (``PRC''). The period of review (``POR'') is August 1, 2011, through July 31, 2012. The review covers one exporter of...

  1. Extracranial stereotactic radiotherapy: preliminary results with the CyberKnife.

    Science.gov (United States)

    Lartigau, Eric; Mirabel, Xavier; Prevost, Bernard; Lacornerie, Thomas; Dubus, Francois; Sarrazin, Thierry

    2009-04-01

    In the field of radiation oncology, equipment for fractionated radiotherapy and single-dose radiosurgery has become increasingly accurate, together with the introduction of robotized treatments. A robot is a device that can be programmed to carry out accurate, repeated and adjusted tasks in a given environment. Treatment of extracranial lesions involves taking into account organ mobility (tumor and healthy tissue) whilst retaining the ability to stereotactically locate the target. New imaging techniques (single-photon emission computed tomography (SPECT), magnetic resonance imaging (MRI), positron emission tomography (PET)) provide further relevant information to slice images (computed tomography (CT) scans, MRI) for target definition. Hypo-fractionated treatments can only be used for curative treatment if the target is accurately defined and tracked during treatment. The CyberKnife is a non-invasive system of radiosurgery and fractionated stereotactic radiotherapy. For intracranial lesions treated by single-dose radiosurgery, it has been used to treat meningioma, acoustic neuromas, pituitary adenoma, metastases, arteriovenous malformations and refractory pain (trigeminal neuralgia). More than 10,000 patients have been treated worldwide. Currently, the most significant developments are in the field of extracranial stereotactic radiotherapy (lung, liver, reirradiation, prostate, etc.). Clinical results obtained in the CyberKnife Nord-Ouest program after 1 year of experience are presented. Copyright 2009 S. Karger AG, Basel.

  2. Image transmission studies

    International Nuclear Information System (INIS)

    Blaine, G.J.; Hill, R.L.; Rueter, A.P.; Senol, E.; Studt, J.W.

    1988-01-01

    This paper discusses radiological PACS image sizes and desired retrieval response time that demand high-bandwidth communication networks. Local area network technology at speeds higher that 10 Megabits/second (IEEE 802.3) have not achieved standardization nor production volume. The authors describe current PACS experiments based on a three-level subnet approach using 10 Mb/s Ethernet channels. An Ethernet channel is shown to support image transfers at an average throughput of 3 Mb/s. Preliminary measurements and simulation results suggest that traffic from as many as two-to-three archives can be supported on the same channel

  3. Sensitivity Measurement of Transmission Computer Tomography: thePreliminary Experimental Study

    International Nuclear Information System (INIS)

    Widodo, Chomsin-S; Sudjatmoko; Kusminarto; Agung-BS Utomo; Suparta, Gede B

    2000-01-01

    This paper reports result of preliminary experimental study onmeasurement method for sensitivity of a computed tomography (CT) scanner. ACT scanner has been build at the Department of Physics, FMIPA UGM and itsperformance based on its sensitivity was measured. The result showed that themeasurement method for sensitivity confirmed this method may be developedfurther as a measurement standard. Although the CT scanner developed has anumber of shortcoming, the analytical results from the sensitivitymeasurement suggest a number of reparations and improvements for the systemso that improved reconstructed CT images can be obtained. (author)

  4. Facial image identification using Photomodeler

    DEFF Research Database (Denmark)

    Lynnerup, Niels; Andersen, Marie; Lauritsen, Helle Petri

    2003-01-01

    consist of many images of the same person taken from different angles. We wanted to see if it was possible to combine such a suite of images in useful 3-D renderings of facial proportions.Fifteen male adults were photographed from four different angles. Based on these photographs, a 3-D wireframe model......We present the results of a preliminary study on the use of 3-D software (Photomodeler) for identification purposes. Perpetrators may be photographed or filmed by surveillance systems. The police may wish to have these images compared to photographs of suspects. The surveillance imagery will often...

  5. Uranium and thorium recovery in thorianite ore-preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Gaiotte, Joao V.M. [Universidade Federal de Alfenas, Pocos de Caldas, MG (Brazil); Villegas, Raul A.S.; Fukuma, Henrique T., E-mail: rvillegas@cnen.gov.br, E-mail: htfukuma@cnen.gov.br [Comissao Nacional de Energia Nuclear (CNEN), Pocos de Caldas, MG (Brazil). Lab. de Pocos de Caldas

    2011-07-01

    This work presents the preliminary results of the studies aiming to develop a hydrometallurgical process to produce uranium and thorium concentrates from thorianite ore from Amapa State, Brazil. This process comprises two major parts: acid leaching and Th/U recovery using solvent extraction strategies. Thorianite ore has a typical composition of 60 - 70% of thorium, 8 - 10% lead and 7 - 10% uranium. Sulfuric acid leaching operational conditions were defined as follows: acid/ore ratio 7.5 t/t, ore size below 65 mesh (Tyler), 2 hours leaching time and temperature of 100 deg C. Leaching tests results showed that uranium and thorium recovery exceeded 95%, whereas 97% of lead ore content remained in the solid form. Uranium and thorium simultaneous solvent extraction is necessary due to high sulfate concentration in the liquor obtained from leaching, so the Primene JM-T primary anime was used for this extraction step. Aqueous raffinate from extraction containing sulfuric acid was recycled to the leaching step, reducing acid uptake around 60%, to achieve a net sulfuric acid consumption of 3 t/t of ore. Uranium and thorium simultaneous stripping was performed using sodium carbonate solution. In the aqueous stripped it was added sulfuric acid at pH 1.5, followed by a second solvent extraction step using the tertiary amine Alamine 336. The following stripping step was done with a solution of sodium chloride, resulting in a final solution of 23 g L-1 uranium. (author)

  6. First results from the Jordan COLTRIMS imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Afaneh, Feras, E-mail: afaneh@hu.edu.jo [Physics Department, The Hashemite University, Zarqa 13115 (Jordan); Ali, Rami; Qasem, Rajaie; Balasmeh, Naeem [Department of Physics, The University of Jordan, Amman 11942 (Jordan); Hamasha, Safeia [Physics Department, The Hashemite University, Zarqa 13115 (Jordan); Dörner, Reinhard; Schmidt-Böcking, Horst [Institut fuer Kernphysik, University Frankfurt, Max-von-Laue-Str. 1, 60438 Frankfurt (Germany)

    2016-08-01

    A Cold Target Recoil Ion Momentum Spectroscopy (COLTRIMS) apparatus has been constructed and operated cooperatively by the Atomic and Molecular Physics Laboratory in the Physics Department at the Hashemite University, Jordan, and the Atomic and Molecular Physics Group at the 4.75 MeV Van de Graaff Accelerator Facility at the University of Jordan. This COLTRIMS imaging system allows the investigation of the dynamics of various ion impact induced atomic and molecular interactions and fragmentations. The performance of the COLTRIMS system was tested by carrying out preliminary studies of two collision systems. In the first study, electron capture processes in the He{sup 2+}–Ne collision system at 0.25 and 1.0 MeV impact energies were investigated. Significant simultaneous electron capture and target excitation has been observed for the 0.25 MeV as opposed to the 1.0 MeV impact energy. In the other study, projectile single electron loss and simultaneous single target ionization in the O{sup +}–He collision system was studied at three different projectile impact energies: 0.6, 1.45 and 2 MeV. Enhancement of the electron–electron contribution to projectile electron loss with increasing collision energy has been observed.

  7. Preliminary results from the Chicago air shower array and the Michigan muon array

    International Nuclear Information System (INIS)

    Krimm, H.A.; Cronin, J.W.; Fick, B.E.; Gibbs, K.G.; Mascarenhas, N.C.; McKay, T.A.; Mueller, D.; Newport, B.J.; Ong, R.A.; Rosenberg, L.J.; Wiedenbeck, M.E.; Green, K.D.; Matthews, J.; Nitz, D.; Sinclair, D.; van der Velde, J.C.

    1991-01-01

    The Chicago Air Shower Array (CASA) is a large area surface array designed to detect extensive air showers (EAS) produced by primaries with energy ∼100 TeV. It operates in coincidence with the underground Michigan Muon Array (MIA). Preliminary results are presented from a search for steady emission and daily emission from three astrophysical sources: Cygnus X-3, Hercules X-1, and the Crab nebula and pulsar. There is no evidence for a significant signal from any of these sources in the 1989 data

  8. Thermoluminescent dosemeters characterization for patient dosimetry in diagnostic radiology preliminary results

    International Nuclear Information System (INIS)

    Castro, William J.; Squair, Peterson L.; Gonzaga, Natalia B.; Nogueira, Maria S.; Silva, Teogenes A. da

    2009-01-01

    The determination of the metrological characteristics of thermoluminescent (TL) dosimeters plays an important role in dosimetry of patients submitted to x-ray examinations for diagnostic purpose. Entrance surface doses can be measured with TL dosimeters to verify the compliance with the diagnostic reference levels. Organ doses can be estimated through TL measurements in an anthropomorphic phantom which it allows the radiation risk assessment. In this work, LiF:Mg,Ti (TLD-100) rod and chip thermoluminescent dosimeters were characterized considering their use for patient dosimetry in computerized tomography and mammography. Preliminary results showed that TL dosimeters have a response reproducibility of 7.8% and 4.8% and homogeneity of 18.4% and 6.5% for rod and chip shapes, respectively. (author)

  9. Preliminary results on epidemiology of Coconut Lethal Yellowing in Ghana

    Directory of Open Access Journals (Sweden)

    Bonnot François

    2009-03-01

    Full Text Available Epidemiological studies are of major importance in understanding the determinants of plant diseases in order to control the risks of their spreading. A research programme on the epidemiology of coconut lethal yellowing, or Cape Saint Paul Wilt Disease (CSPWD, in Ghana was launched in March 2007. The objective was to characterize the distribution and spread of the disease in space and time at various scales, and their relation with the environment. This article presents the general strategy used to evaluate the incidence of CSPWD along with the environmental, ecological and agronomical variables at regional level. A survey was undertaken on 1,166 plots of Coconut Sector Development Project (CSDP planted with Malayan Yellow Dwarf (MYD × Vanuatu Tall (VTT hybrids in Western Region and Central Region. Preliminary results on the distribution of CSPWD and outside variables at regional scale, along with their relations, are given.

  10. PET/MRI: a novel hybrid imaging technique. Major clinical indications and preliminary experience in Brazil.

    Science.gov (United States)

    Vitor, Taise; Martins, Karine Minaif; Ionescu, Tudor Mihai; Cunha, Marcelo Livorsi da; Baroni, Ronaldo Hueb; Garcia, Marcio Ricardo Taveira; Wagner, Jairo; Campos, Guilherme de Carvalho; Nogueira, Solange Amorim; Guerra, Elaine Gonçalves; Amaro, Edson

    2017-01-01

    In recent years, medical imaging with hybrid techniques has widely accepted and employed in clinical routine. PET/MRI offers significant advantages, including excellent contrast and resolution and reduced ionizing radiation, as compared to well-established PET/CT. Therefore, PET/MRI is a promising modality for oncologic imaging of some regions, such as brain, head and neck, liver and pelvis. This article set out to analyze clinical conditions that could benefit from PET/MRI imaging based on our caseload. The potential of PET/MRI to become the imaging modality of choice for assessment of neurologic and oncologic conditions associated with soft tissues is highlighted. Clinical aspects of PET/MRI and its application to clinical cases are illustrated with examples extracted from the authors' preliminary experience. RESUMO Nos últimos anos, imagens médicas com tecnologias híbridas tornaram-se amplamente aceitas e utilizadas na prática clínica. O PET/RM possui vantagens importantes, incluindo excelentes contrastes e resolução, e menor radiação ionizante, em comparação ao PET/TC. Por isto, é uma modalidade promissora para exames de imagem de pacientes oncológicos, para avaliar o cérebro, cabeça e pescoço, o fígado e a pelve. O objetivo deste artigo foi analisar as situações clínicas que se beneficiariam de exames de PET/RM a partir de uma casuística. Destacamos o potencial desta técnica se tornar o método de imagem de escolha para doenças neurológicas e oncológicas que envolvam partes moles. Os aspectos clínicos de PET/RM e sua aplicação aos casos clínicos são ilustrados com exemplos da experiência inicial dos autores.

  11. Three dimensional CT imaging of ossicular chain: a preliminary study

    International Nuclear Information System (INIS)

    Hu Chunhong; Zhong Shenbin; Fu Yindi; Zhu Wei; Wang Xueyuan; Chen Jianhua; Ding Yi

    2001-01-01

    Objective: To analysis the features of normal and abnormal ossicular chain in three dimensional images and asses the best parameters and its usefulness in diagnosis and treatment of chronic otitis media (COM). Methods: All patients, including 43 patients with normal ears and 24 ears with COM, were examined using spiral CT with inner ear software, 1-mm slice width and 1 pitch. SSD method was used in three dimensional reconstruction and the threshold was 100-300 Hu. Results: In normal cases, Malleus, incus, stapes crura, incudomalleal joints and incudostapedial joints were displayed well, but stapes footplate unsatisfactorily. The disruption of the ossicular chain showed in three-dimensional images in cases of chronic otitis media was in accord with that seen in the operation. Conclusion: It is very important for imaging with high quality through selecting proper parameters, and three-dimensional image can provide valuable information for surgery

  12. 78 FR 13321 - Silicon Metal From the People's Republic of China: Preliminary Results of Antidumping Duty...

    Science.gov (United States)

    2013-02-27

    ... People's Republic of China: Preliminary Results of Antidumping Duty Administrative Review; 2011-2012... administrative review of the antidumping duty order on silicon metal from the People's Republic of China (``PRC'') for the period of review (``POR'') June 1, 2011, through May 31, 2012. This review covers one PRC...

  13. Tellurium in active volcanic environments: Preliminary results

    Science.gov (United States)

    Milazzo, Silvia; Calabrese, Sergio; D'Alessandro, Walter; Brusca, Lorenzo; Bellomo, Sergio; Parello, Francesco

    2014-05-01

    Tellurium is a toxic metalloid and, according to the Goldschmidt classification, a chalcophile element. In the last years its commercial importance has considerably increased because of its wide use in solar cells, thermoelectric and electronic devices of the last generation. Despite such large use, scientific knowledge about volcanogenic tellurium is very poor. Few previous authors report result of tellurium concentrations in volcanic plume, among with other trace metals. They recognize this element as volatile, concluding that volcanic gases and sulfur deposits are usually enriched with tellurium. Here, we present some results on tellurium concentrations in volcanic emissions (plume, fumaroles, ash leachates) and in environmental matrices (soils and plants) affected by volcanic emissions and/or deposition. Samples were collected at Etna and Vulcano (Italy), Turrialba (Costa Rica), Miyakejima, Aso, Asama (Japan), Mutnovsky (Kamchatka) at the crater rims by using common filtration techniques for aerosols (polytetrafluoroethylene filters). Filters were both eluted with Millipore water and acid microwave digested, and analyzed by inductively coupled plasma mass spectrometry (ICP-MS). Volcanic ashes emitted during explosive events on Etna and Copahue (Argentina) were analyzed for tellurium bulk composition and after leaching experiments to evaluate the soluble fraction of tellurium. Soils and leaves of vegetation were also sampled close to active volcanic vents (Etna, Vulcano, Nisyros, Nyiragongo, Turrialba, Gorely and Masaya) and investigated for tellurium contents. Preliminary results showed very high enrichments of tellurium in volcanic emissions comparing with other volatile elements like mercury, arsenic, thallium and bismuth. This suggests a primary transport in the volatile phase, probably in gaseous form (as also suggested by recent studies) and/or as soluble salts (halides and/or sulfates) adsorbed on the surface of particulate particles and ashes. First

  14. Preliminary Results of Autotuning GEMM Kernels for the NVIDIA Kepler Architecture- GeForce GTX 680

    Energy Technology Data Exchange (ETDEWEB)

    Kurzak, Jakub [Univ. of Tennessee, Knoxville, TN (United States); Luszczek, Pitor [Univ. of Tennessee, Knoxville, TN (United States); Tomov, Stanimire [Univ. of Tennessee, Knoxville, TN (United States); Dongarra, Jack [Univ. of Tennessee, Knoxville, TN (United States); Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Univ. of Manchester (United Kingdom)

    2012-04-01

    Kepler is the newest GPU architecture from NVIDIA, and the GTX 680 is the first commercially available graphics card based on that architecture. Matrix multiplication is a canonical computational kernel, and often the main target of initial optimization efforts for a new chip. This article presents preliminary results of automatically tuning matrix multiplication kernels for the Kepler architecture using the GTX 680 card.

  15. Monte Carlo modeling of neutron imaging at the SINQ spallation source

    International Nuclear Information System (INIS)

    Lebenhaft, J.R.; Lehmann, E.H.; Pitcher, E.J.; McKinney, G.W.

    2003-01-01

    Modeling of the Swiss Spallation Neutron Source (SINQ) has been used to demonstrate the neutron radiography capability of the newly released MPI-version of the MCNPX Monte Carlo code. A detailed MCNPX model was developed of SINQ and its associated neutron transmission radiography (NEUTRA) facility. Preliminary validation of the model was performed by comparing the calculated and measured neutron fluxes in the NEUTRA beam line, and a simulated radiography image was generated for a sample consisting of steel tubes containing different materials. This paper describes the SINQ facility, provides details of the MCNPX model, and presents preliminary results of the neutron imaging. (authors)

  16. Holy images on blades: unique swords from the State Hermitage Museum (preliminary publication

    Directory of Open Access Journals (Sweden)

    Vsevolod Obraztsov

    2013-12-01

    Full Text Available The focus of this article are interesting rarities from the collection of the State Hermitage Museum - swords of the 17th-18th centuries with inscriptions in Greek and Slavonic, with images of Christian saints inlaid in gold. The authors offer the general characteristics of 17 exemplars of this kind of arms which are divided into several groups according to the shape of the hilt. A brief overview of the relatively few publications on this subject includes articles by Vasilii Prokhorov (1877; data from the Index of the Medieval Department of the Imperial Hermitage published by Nikodim Kondakov (1891, a catalogue of Count Sergei Sheremetev's collection of arms compiled by Eduard Lenz (1895, and a monograph by E. Astvatsaturian on Turkish arms from the collection of the State Historical Museum (2002. The authors pay special attention to the description and analysis of two swords from the Hermit- age collection. One of them belonged to Count Michail Miloradovich, and was presented to him in 1807 from the city of Bucharest. The second sword came to the Hermitage after the Bolshevik Revolution from the Marble Palace, the residency of the Grand Dukes Konstantinovichi. Besides the traditional inscriptions and images of the Virgin with Child crowned by angels, the blade bears a unique image of Byzantine Emperor Nikephoros Phokas blessed by Jesus Christ with both hands. There are also two cartouches with quotations from Psalms in Greek. The extremely rich décor of this sword and the unique depiction of the Byzantine Emperor leave no doubt that they were made on a special order. The authors connect the sword to the Greek Project initiated by the Russian Empress Catherine the Great. The main idea of the project was a restoration of the Byzantine Empire with Constantinople-Istanbul as its capital, where Grand Duke Konstantin, Catherine the Great's grandchild, would be ascended to the throne. This article is a preliminary publication of a project in process

  17. Functional MR imaging of cerebral auditory cortex with linguistic and non-linguistic stimulation: preliminary study

    International Nuclear Information System (INIS)

    Kang, Su Jin; Kim, Jae Hyoung; Shin, Tae Min

    1999-01-01

    To obtain preliminary data for understanding the central auditory neural pathway by means of functional MR imaging (fMRI) of the cerebral auditory cortex during linguistic and non-linguistic auditory stimulation. In three right-handed volunteers we conducted fMRI of auditory cortex stimulation at 1.5 T using a conventional gradient-echo technique (TR/TE/flip angle: 80/60/40 deg). Using a pulsed tone of 1000 Hz and speech as non-linguistic and linguistic auditory stimuli, respectively, images-including those of the superior temporal gyrus of both hemispheres-were obtained in sagittal plases. Both stimuli were separately delivered binaurally or monoaurally through a plastic earphone. Images were activated by processing with homemade software. In order to analyze patterns of auditory cortex activation according to type of stimulus and which side of the ear was stimulated, the number and extent of activated pixels were compared between both temporal lobes. Biaural stimulation led to bilateral activation of the superior temporal gyrus, while monoaural stimulation led to more activation in the contralateral temporal lobe than in the ipsilateral. A trend toward slight activation of the left (dominant) temporal lobe in ipsilateral stimulation, particularly with a linguistic stimulus, was observed. During both biaural and monoaural stimulation, a linguistic stimulus produced more widespread activation than did a non-linguistic one. The superior temporal gyri of both temporal lobes are associated with acoustic-phonetic analysis, and the left (dominant) superior temporal gyrus is likely to play a dominant role in this processing. For better understanding of physiological and pathological central auditory pathways, further investigation is needed

  18. Development of a distress inventory for cancer: preliminary results.

    Directory of Open Access Journals (Sweden)

    Thomas B

    2002-01-01

    Full Text Available CONTEXT: Advances in cancer treatment have led to cure and prolongation of patients′ lives; however associated psychosocial problems, including distress, can detrimentally affect patients′ compliance with treatment and ultimately, their outcome. Symptom distress has been well addressed in many studies; however, psychological distress has only been quantified by using depression or anxiety scales/checklists or quality of life scales containing a distress sub scale/component or by the use of scales that are not psychological distress-specific. AIMS: The present study is an attempt to construct a psychological distress inventory for specific use with cancer patients. SETTINGS AND DESIGN: The standardisation sample consisted of 63 randomly selected patients with head and neck cancer who had undergone/ were undergoing curative treatment at the Regional Cancer Centre, Trivandrum. PATIENTS AND METHODS: The Distress Inventory for Cancer contained 57 positively and negatively toned items. An item analysis was conducted, followed by a factor analysis, thereby identifying the domains influencing distress. RESULTS: The final questionnaire contained 26 items subdivided into four domains viz. the personal, spiritual, physical, and the family domains, with each domain providing a sub score. The reliability coefficient (Cronbach′s alpha of the scale was found to be 0.85. CONCLUSIONS: These are the preliminary results of an ongoing study on global distress and tool development process. Reported here is the first step towards development of such tool.

  19. Stokes polarimetry probe for skin lesion evaluation: preliminary results

    Science.gov (United States)

    Louie, Daniel C.; Tchvialeva, Lioudmilla; Kalia, Sunil; Lui, Harvey; Lee, Tim K.

    2018-02-01

    This paper reports on the design of a prototype in-vivo Stokes polarimetry probe for skin lesion evaluation, and preliminary results from skin phantom and clinical trials of this device. The probe releases a single millisecond-long pulse from a laser diode with either linear or circular polarization. It then captures the resulting backscattered far-field polarization speckle and calculates the Stokes parameters. This probe was designed with three novel innovations in mind. First, the Stokes vector is captured quickly, using low-cost components without the use of moving parts. Second, a compact collimated laser diode was used as the light source. Third, the device and detector geometry were designed to produce and capture a uniform speckle field. In the first clinical trial of this device, measurements were taken from a variety of skin lesions, both cancerous and benign. The Stokes vector was measured and used to calculate the degree of polarization (DOP), the azimuth angle, and the ellipticity angle of the polarization ellipse for two input light polarizations. Among other findings, the DOP for circular polarized input light was consistently lower than the DOP for linear polarized input light. These findings indicate the potential for a fast and low-cost in-vivo skin cancer screening tool, and encourages the continuing development of this probe's techniques.

  20. Preliminary results from the U.S. participation in the 2000 Beam Park Experiment

    Science.gov (United States)

    Stansbery, Gene

    2001-10-01

    The United States participated in the 2000 Beam Park Experiment (BPE) conducted in late October, 2000 under the auspices of the Inter-Agency Space Debris Coordination Committee (IADC). The U.S. participated using several sensors which have participated in previous campaigns: Haystack, TRADEX, and COBRA DANE radars, and the Liquid Mirror Telescope. New to the BPE experiments this time are the GBR-P radar located at Kwajalein Atoll and the Haystack Auxiliary (HAX) radar located in Massachusetts. This paper will present and discuss preliminary results from each of the participating U.S. sensors.

  1. Preliminary Results on the Experimental Investigation of the Structure Functions of Bound Nucleons

    Energy Technology Data Exchange (ETDEWEB)

    Bodek, Arie [Univ. of Rochester, NY (United States); Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2016-08-01

    We present preliminary results on an experimental study of the nuclear modification of the longitudinal ($\\sigma_L$) and transverse ($\\sigma_T$) structure functions of nucleons bound in nuclear targets. The origin of these modifications (commonly referred as as the EMC effect) is not fully understood. Our measurements of R= $\\sigma_L / \\sigma_T$ for nuclei ($R_A$) and for deuterium ($R_D$) indicate that nuclear modifications of the structure functions of bound nucleons are different for the longitudinal and transverse structure functions, and that contrary to expectation from several theoretical models, $R_A< R_D$.

  2. ROUND-ROBIN ATOM-PROBE EXPERIMENT : PRELIMINARY RESULTS IN JAPAN

    OpenAIRE

    Nakamura , S.

    1986-01-01

    A round-robin experiment were to be carried out by 6 laboratories in Japan (Nishikawa ; Tokyo Inst. Tech., Sakurai and Igata ; Univ. of Tokyo, Ishikawa ; Hitachi, Tanino ; Nippon Steel Corp. and Nakamura ; Osaka Univ.) under the normal operating condition (T < l00 °K,. pulse fraction ~ 15% ~, P < 10-9 torr). Fe-Cr-Al and W-25%Re alloys, which are divided from a single wire were chosen as the specimen materials. A preliminary analysis of the W-Re alloy of the laboratory concerned show the good...

  3. Preliminary 2D design study for A ampersand PCT

    International Nuclear Information System (INIS)

    Keto, E.; Azevedo, S.; Roberson, P.

    1995-03-01

    Lawrence Livermore National Laboratory is currently designing and constructing a tomographic scanner to obtain the most accurate possible assays of radioactivity in barrels of nuclear waste in a limited amount of time. This study demonstrates a method to explore different designs using laboratory experiments and numerical simulations. In particular, we examine the trade-off between spatial resolution and signal-to-noise. The simulations are conducted in two dimensions as a preliminary study for three dimensional imaging. We find that the optimal design is entirely dependent on the expected source sizes and activities. For nuclear waste barrels, preliminary results indicate that collimators with widths of 1 to 3 inch and aspect ratios of 5:1 to 10:1 should perform well. This type of study will be repeated in 3D in more detail to optimize the final design

  4. Design of e-Science platform for biomedical imaging research cross multiple academic institutions and hospitals

    Science.gov (United States)

    Zhang, Jianguo; Zhang, Kai; Yang, Yuanyuan; Ling, Tonghui; Wang, Tusheng; Wang, Mingqing; Hu, Haibo; Xu, Xuemin

    2012-02-01

    More and more image informatics researchers and engineers are considering to re-construct imaging and informatics infrastructure or to build new framework to enable multiple disciplines of medical researchers, clinical physicians and biomedical engineers working together in a secured, efficient, and transparent cooperative environment. In this presentation, we show an outline and our preliminary design work of building an e-Science platform for biomedical imaging and informatics research and application in Shanghai. We will present our consideration and strategy on designing this platform, and preliminary results. We also will discuss some challenges and solutions in building this platform.

  5. Preliminary study of synthetic aperture tissue harmonic imaging on in-vivo data

    DEFF Research Database (Denmark)

    Rasmussen, Joachim Hee; Hemmsen, Martin Christian; Sloth Madsen, Signe

    2013-01-01

    . Results from the image quality study show, that in the current configuration on the UltraView system, where no transmit apodization was applied, SASB-THI and DRF-THI produced equally good images. It is expected that given the use of transmit apodization, SASB-THI could be further improved.......A method for synthetic aperture tissue harmonic imaging is investigated. It combines synthetic aperture sequential beamforming (SASB) with tissue harmonic imaging (THI) to produce an increased and more uniform spatial resolution and improved side lobe reduction compared to conventional B......-mode imaging. Synthetic aperture sequential beamforming tissue harmonic imaging (SASB-THI) was implemented on a commercially available BK 2202 Pro Focus UltraView ultrasound system and compared to dynamic receive focused tissue harmonic imaging (DRF-THI) in clinical scans. The scan sequence...

  6. Use of the KineSpring system in the treatment of medial knee osteoarthritis: preliminary results.

    Science.gov (United States)

    Madonna, Vincenzo; Condello, Vincenzo; Piovan, Gianluca; Screpis, Daniele; Zorzi, Claudio

    2015-01-01

    the purpose of this study was to analyze our preliminary results obtained with the KineSpring system in patients suffering from medial compartment knee osteoarthritis (OA). between September 2012 and May 2014, 53 patients underwent treatment with the KineSpring system. Patient self-assessment was performed pre-operatively and at 3, 6 and 12 months postoperatively, and included the KOOS, Tegner activity score, Lysholm functional knee score, VAS knee pain score, and IKDC score. Device- and procedure-related adverse events were recorded. mean KOOS subscales, except for the Sport/Recreation subscale at six months, improved over time. Mean WOMAC Pain and Function domains, Lysholm score, IKDC score and VAS knee pain score improved over the follow-up period and were significantly improved at 3, 6 and 12 months postoperatively compared to baseline. Mean Tegner score improved slightly over time. In 5 of the 53 (9.4%) patients re-operation was necessary. In 3 patients the device was removed due to infection (one case) or persistent knee pain (two cases). Surgical arthrolysis was performed in two patients. in our preliminary experience, the KineSpring system gave good short-term clinical results. Level IV, therapeutic case series.

  7. Preliminary results of a multidisciplinary geophysical investigation in an archaeological area near Rome, with remains of a vast imperial age Roman villa

    Science.gov (United States)

    Florindo, F.; Sapia, V.; Marchetti, M.

    2017-12-01

    We present preliminary results of a multidisciplinary geophysical investigation applied to the subsoil imaging of the archaeological site of Cocciano, near Rome. The area was place of a series of archaeological findings, which are generally recognized as the remains of a vast Roman villa of the imperial age, notably attributed to Emperor Tiberius. We acquired capacitive coupled resistivity data along two parallel profiles and we performed a magnetic survey over a small subset of the survey area. The recovered resistivity models suggest the presence of a shallow, sub-horizontal, resistive layer (ρ > 350 Ωm), of slightly variable thickness (2 - 3 m), which we interpret as the response of ancient substructions overlying a relatively low-resistive layer, which we ascribe to the geological substratum. Processed magnetic data show a clear magnetic signature aligned to form a curve-shaped anomaly right at the prosecution of a nearby, partially exposed, ancient wall.

  8. Results from neutron imaging of ICF experiments at NIF

    Science.gov (United States)

    Merrill, F. E.; Danly, C. R.; Fittinghoff, D. N.; Grim, G. P.; Guler, N.; Volegov, P. L.; Wilde, C. H.

    2016-03-01

    In 2011 a neutron imaging diagnostic was commissioned at the National Ignition Facility (NIF). This new system has been used to collect neutron images to measure the size and shape of the burning DT plasma and the surrounding fuel assembly. The imaging technique uses a pinhole neutron aperture placed between the neutron source and a neutron detector. The detection system measures the two-dimensional distribution of neutrons passing through the pinhole. This diagnostic collects two images at two times. The long flight path for this diagnostic, 28 m, results in a chromatic separation of the neutrons, allowing the independently timed images to measure the source distribution for two neutron energies. Typically one image measures the distribution of the 14 MeV neutrons, and the other image measures the distribution of the 6-12 MeV neutrons. The combination of these two images has provided data on the size and shape of the burning plasma within the compressed capsule, as well as a measure of the quantity and spatial distribution of the cold fuel surrounding this core. Images have been collected for the majority of the experiments performed as part of the ignition campaign. Results from this data have been used to estimate a burn-averaged fuel assembly as well as providing performance metrics to gauge progress towards ignition. This data set and our interpretation are presented.

  9. A technique to consider mismatches between fMRI and EEG/MEG sources for fMRI-constrained EEG/MEG source imaging: a preliminary simulation study

    International Nuclear Information System (INIS)

    Im, Chang-Hwan; Lee, Soo Yeol

    2006-01-01

    fMRI-constrained EEG/MEG source imaging can be a powerful tool in studying human brain functions with enhanced spatial and temporal resolutions. Recent studies on the combination of fMRI and EEG/MEG have suggested that fMRI prior information could be readily implemented by simply imposing different weighting factors to cortical sources overlapping with the fMRI activations. It has been also reported, however, that such a hard constraint may cause severe distortions or elimination of meaningful EEG/MEG sources when there are distinct mismatches between the fMRI activations and the EEG/MEG sources. If one wants to obtain the actual EEG/MEG source locations and uses the fMRI prior information as just an auxiliary tool to enhance focality of the distributed EEG/MEG sources, it is reasonable to weaken the strength of fMRI constraint when severe mismatches between fMRI and EEG/MEG sources are observed. The present study suggests an efficient technique to automatically adjust the strength of fMRI constraint according to the mismatch level. The use of the proposed technique rarely affects the results of conventional fMRI-constrained EEG/MEG source imaging if no major mismatch between the two modalities is detected; while the new results become similar to those of typical EEG/MEG source imaging without fMRI constraint if the mismatch level is significant. A preliminary simulation study using realistic EEG signals demonstrated that the proposed technique can be a promising tool to selectively apply fMRI prior information to EEG/MEG source imaging

  10. Preliminary Experimental Results for Indirect Vector-Control of Induction Motor Drives with Forced Dynamics

    Directory of Open Access Journals (Sweden)

    Jan Vittek

    2003-01-01

    Full Text Available The contribution presents an extension of indirect vector control of electric drives employing induction motors to 'Forced Dynamic Control'. This method of control offers an accurate realisation of dynamic response profiles, which can be selected by the user. The developed system can be integrated into a drive with a shaft position encoder or a shaft sensoriess drive, in which only the stator currents are measured. The applied stator voltages are determined by a computed inverter switching algorithm. Simulation results and preliminary experimental results for indirect vector control of an idle running induction motor indicate good agreement with the theoretical predictions.

  11. Preliminary results of the first paleontologic investigations in Uruguayan Antarctica

    International Nuclear Information System (INIS)

    Perea, D.; Masquelin, E.; Verde, M.; Querequiz, R.

    1998-01-01

    Preliminary results of the first Uruguayan paleontollogic and biostratigraphical investigations in Antartica are presented. The field work was performed in fildes Peninsula, King George Island, near Uruguayan station Base Cientifica Antarctica Artigas.Some fossiliferous outcrops were geologic and paleontologically analyzed, among them Fossil Hills, situated in the center part of the peninsula, in front of Ardley Island, between the chinese and chilean stations.This hill is composed of fossil bearing piroclastic and epiclastic rocks, assigned to the fossil Hill Fm. Vegetal remains(petrified wood and leaf impronts) were observed and collected in this unit and it is remarkable the presence of Nothofagus sp. and invertebrate trace fossils, Cochlichmus isp and Helminthopsis isp.The depositional environment deduced from the fossil association in lacustrine, under a warm and humid climate.In the same deposits, other investigators have collected aquatic and ratite bird trace fossils. Paleontologic evidence is not contradictory with the Eocene age previously proposed for the studied deposits. (author)

  12. Raman scattering investigation of the water-bridge phenomenon: Some preliminary results

    Directory of Open Access Journals (Sweden)

    Francesco Aliotta

    2010-09-01

    Full Text Available A floating water-bridge is formed if a high-voltage direct current is applied between two beakers filled of chemically pure water. Raman spectra of the OH-stretching region have been obtained at ambient condition of temperature and pressure. These preliminary results seem to indicate that the hydrogen-bond structure is only slightly modified by the presence of the electric field applied to form the floating water-bridge in agreement with recent neutron scattering investigation. In fact, the polarized Raman spectrum of the pure water and of the water-bridge is almost superimposable. We are planning to carry out further spectroscopic analysis, at different thermodynamic conditions, for better understanding the role played by the hydrogen-bond in driving the formation of the floating water-bridge.

  13. 75 FR 78968 - Magnesium Metal From the Russian Federation: Extension of Time Limit for Preliminary Results of...

    Science.gov (United States)

    2010-12-17

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-821-819] Magnesium Metal From the Russian Federation: Extension of Time Limit for Preliminary Results of Antidumping Duty Administrative... administrative review of the antidumping duty order on magnesium metal from the Russian Federation for the period...

  14. 77 FR 11065 - Certain Pasta From Turkey: Extension of Time Limit for the Preliminary Results of the...

    Science.gov (United States)

    2012-02-24

    ... DEPARTMENT OF COMMERCE International Trade Administration [C-489-806] Certain Pasta From Turkey: Extension of Time Limit for the Preliminary Results of the Countervailing Duty Administrative Review AGENCY... initiation of administrative review of the countervailing duty order on certain pasta from Turkey, covering...

  15. 77 FR 15718 - Certain Pasta from Italy: Extension of Time Limit for the Preliminary Results of the...

    Science.gov (United States)

    2012-03-16

    ... DEPARTMENT OF COMMERCE International Trade Administration [C-475-819] Certain Pasta from Italy: Extension of Time Limit for the Preliminary Results of the Countervailing Duty Administrative Review AGENCY... notice of initiation of administrative review of the countervailing duty order on certain pasta from...

  16. 76 FR 6604 - Certain Pasta From Italy: Extension of Time Limit for the Preliminary Results of the...

    Science.gov (United States)

    2011-02-07

    ... DEPARTMENT OF COMMERCE International Trade Administration [C-475-819] Certain Pasta From Italy: Extension of Time Limit for the Preliminary Results of the Countervailing Duty Administrative Review AGENCY... initiation of administrative review of the countervailing duty order on certain pasta from Italy, covering...

  17. 77 FR 17410 - Solid Urea From the Russian Federation: Extension of Time Limit for Preliminary Results of...

    Science.gov (United States)

    2012-03-26

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-821-801] Solid Urea From the Russian Federation: Extension of Time Limit for Preliminary Results of Antidumping Duty Administrative Review AGENCY... Commerce (the Department) initiated an administrative review of the antidumping duty order on solid urea...

  18. 75 FR 19369 - Certain Hot-Rolled Flat-Rolled Carbon Quality Steel Products from Brazil: Preliminary Results of...

    Science.gov (United States)

    2010-04-14

    .... Hot-rolled dual phase steel, phase-hardened, primarily with a ferritic-martensitic microstructure.... See Preliminary Results of Antidumping Duty Administrative Review: Stainless Steel Sheet and Strip in... Antidumping Duty Administrative Review: Stainless Steel Sheet and Strip in Coils From France, 68 FR 69379...

  19. 78 FR 55676 - Certain Frozen Fish Fillets From the Socialist Republic of Vietnam: Preliminary Results of the...

    Science.gov (United States)

    2013-09-11

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-552-801] Certain Frozen Fish Fillets... order on certain frozen fish fillets (``fish fillets'') from the Socialist Republic of Vietnam... preliminary results. \\1\\ See Notice of Antidumping Duty Order: Certain Frozen Fish Fillets From the Socialist...

  20. 78 FR 34340 - Welded Carbon Steel Standard Pipe and Tube Products From Turkey: Preliminary Results of...

    Science.gov (United States)

    2013-06-07

    ... Pipe and Tube Products From Turkey: Preliminary Results of Antidumping Duty Administrative Review; 2011... tube products (welded pipe and tube) from Turkey.\\2\\ The period of review is May 1, 2011, to April 30... A.S. (BMB) had reviewable sales during this period of review. DATES: As of June 7, 2013. FOR FURTHER...

  1. Paediatric x-ray radiation dose reduction and image quality analysis.

    Science.gov (United States)

    Martin, L; Ruddlesden, R; Makepeace, C; Robinson, L; Mistry, T; Starritt, H

    2013-09-01

    Collaboration of multiple staff groups has resulted in significant reduction in the risk of radiation-induced cancer from radiographic x-ray exposure during childhood. In this study at an acute NHS hospital trust, a preliminary audit identified initial exposure factors. These were compared with European and UK guidance, leading to the introduction of new factors that were in compliance with European guidance on x-ray tube potentials. Image quality was assessed using standard anatomical criteria scoring, and visual grading characteristics analysis assessed the impact on image quality of changes in exposure factors. This analysis determined the acceptability of gradual radiation dose reduction below the European and UK guidance levels. Chest and pelvis exposures were optimised, achieving dose reduction for each age group, with 7%-55% decrease in critical organ dose. Clinicians confirmed diagnostic image quality throughout the iterative process. Analysis of images acquired with preliminary and final exposure factors indicated an average visual grading analysis result of 0.5, demonstrating equivalent image quality. The optimisation process and final radiation doses are reported for Carestream computed radiography to aid other hospitals in minimising radiation risks to children.

  2. Paediatric x-ray radiation dose reduction and image quality analysis

    International Nuclear Information System (INIS)

    Martin, L; Ruddlesden, R; Mistry, T; Starritt, H; Makepeace, C; Robinson, L

    2013-01-01

    Collaboration of multiple staff groups has resulted in significant reduction in the risk of radiation-induced cancer from radiographic x-ray exposure during childhood. In this study at an acute NHS hospital trust, a preliminary audit identified initial exposure factors. These were compared with European and UK guidance, leading to the introduction of new factors that were in compliance with European guidance on x-ray tube potentials. Image quality was assessed using standard anatomical criteria scoring, and visual grading characteristics analysis assessed the impact on image quality of changes in exposure factors. This analysis determined the acceptability of gradual radiation dose reduction below the European and UK guidance levels. Chest and pelvis exposures were optimised, achieving dose reduction for each age group, with 7%–55% decrease in critical organ dose. Clinicians confirmed diagnostic image quality throughout the iterative process. Analysis of images acquired with preliminary and final exposure factors indicated an average visual grading analysis result of 0.5, demonstrating equivalent image quality. The optimisation process and final radiation doses are reported for Carestream computed radiography to aid other hospitals in minimising radiation risks to children. (paper)

  3. A kit prepared technetium-99m agent for cardiac imaging: a preliminary evaluation in dogs

    International Nuclear Information System (INIS)

    Thakur, M.L.

    1982-01-01

    A new 99mTc cardiac agent that can be prepared by a kit method has been developed. The preliminary results in animals indicate that the agent is distributed in the myocardium according to the regional myocardial blood flow and has ability to delineate a myocardial region of infarction

  4. Preliminary results from MBE-4: A four beam induction linac for heavy ion fusion research

    International Nuclear Information System (INIS)

    Fessenden, T.J.; Judd, D.L.; Keefe, D.; Kim, C.; Laslett, L.J.; Smith, L.; Warwick, A.I.; Warwick, P.b.A.I.

    1986-01-01

    Preliminary results are presented from a scaled experimental multiple beam induction linac. This experiment is part of a program of accelerator research for heavy ion fusion. It is shown that multiple beams can be accelerated without significant mutual interaction. Measurements of the longitudinal dynamics of a current-amplifying induction linac are presented and compared to calculations. Coupling of transverse and longitudinal dynamics is discussed

  5. Preliminary results from MBE-4: a four beam induction linac for heavy ion fusion research

    International Nuclear Information System (INIS)

    Fessenden, T.J.; Judd, D.L.; Keefe, D.; Kim, C.; Laslett, L.J.; Smith, L.; Warwick, A.I.

    1986-05-01

    Preliminary results are presented from a scaled experimental multiple beam induction linac. This experiment is part of a program of accelerator research for heavy ion fusion. It is shown that multiple beams can be accelerated without significant mutual interaction. Measurements of the longitudinal dynamics of a current-amplifying induction linac are presented and compared to calculations. Coupling of transverse and longitudinal dynamics is discussed

  6. Preliminary results about Electrodeposition of Cobalt at laboratory level

    International Nuclear Information System (INIS)

    Cornejo, N.

    1992-01-01

    As of an organic compound, an extraction and Cobalt electrodeposition method had been developed as a part of fabrication aim of a sealed radioactive source with objective to the construction of density meter prototype. It was performed preliminary test of electrodeposition in the laboratory level in a simple cell. The used electrolyte had been a sulphate solution obtained by extraction of an organic solution. It is obtained a Co film by electrodeposition at 55 o C temperature and with an approximately Co concentration in 70 g/lt. (Author) 3 refs., 1 fig., 1 tab

  7. Photoacoustic imaging for differential diagnosis of benign polyps versus malignant polyps of the gallbladder: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Chae, Hee Dong; Lee, Jae Young; Han, Joon Koo [Dept. of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul National University Hospital, Seoul (Korea, Republic of); Jang, Jin Young; Kang, Mee Joo [Div. of Hepatobiliary-Pancreatic Surgery, Department of Surgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Chang, Jin Ho; Kang, Jeeun [Sogang University, Seoul (Korea, Republic of)

    2017-09-15

    To investigate the feasibility of ex vivo multispectral photoacoustic (PA) imaging in differentiating cholesterol versus neoplastic polyps, and benign versus malignant polyps, of the gallbladder. A total of 38 surgically confirmed gallbladder polyps (24 cholesterol polyps, 4 adenomas, and 10 adenocarcinomas) from 38 patients were prospectively included in this study. The surgical specimens were set on a gel pad immersed in a saline-filled container. The PA intensities of polyps were then measured, using two separate wavelength intervals (421–647 nm and 692–917 nm). Mann-Whitney U test was performed for the comparison of normalized PA intensities between the cholesterol and neoplastic polyps, and between the benign and malignant polyps. Kruskal-Wallis test was conducted for the comparison of normalized PA intensities among the cholesterol polyps, adenomas, and adenocarcinomas. A significant difference was observed in the normalized PA intensities between the cholesterol and neoplastic polyps at 459 nm (median, 1.00 vs. 0.73; p = 0.032). Comparing the benign and malignant polyps, there were significant differences in the normalized PA intensities at 765 nm (median, 0.67 vs. 0.78; p = 0.013), 787 nm (median, 0.65 vs. 0.77; p = 0.034), and 853 nm (median, 0.59 vs. 0.85; p = 0.028). The comparison of the normalized PA intensities among cholesterol polyps, adenomas, and adenocarcinomas demonstrated marginally significant differences at 765 nm (median, 0.67 vs. 0.66 vs. 0.78, respectively; p = 0.049). These preliminary results indicate that benign versus malignant gallbladder polyps might exhibit different spectral patterns on multispectral PA imaging.

  8. Photoacoustic imaging for differential diagnosis of benign polyps versus malignant polyps of the gallbladder: A preliminary study

    International Nuclear Information System (INIS)

    Chae, Hee Dong; Lee, Jae Young; Han, Joon Koo; Jang, Jin Young; Kang, Mee Joo; Chang, Jin Ho; Kang, Jeeun

    2017-01-01

    To investigate the feasibility of ex vivo multispectral photoacoustic (PA) imaging in differentiating cholesterol versus neoplastic polyps, and benign versus malignant polyps, of the gallbladder. A total of 38 surgically confirmed gallbladder polyps (24 cholesterol polyps, 4 adenomas, and 10 adenocarcinomas) from 38 patients were prospectively included in this study. The surgical specimens were set on a gel pad immersed in a saline-filled container. The PA intensities of polyps were then measured, using two separate wavelength intervals (421–647 nm and 692–917 nm). Mann-Whitney U test was performed for the comparison of normalized PA intensities between the cholesterol and neoplastic polyps, and between the benign and malignant polyps. Kruskal-Wallis test was conducted for the comparison of normalized PA intensities among the cholesterol polyps, adenomas, and adenocarcinomas. A significant difference was observed in the normalized PA intensities between the cholesterol and neoplastic polyps at 459 nm (median, 1.00 vs. 0.73; p = 0.032). Comparing the benign and malignant polyps, there were significant differences in the normalized PA intensities at 765 nm (median, 0.67 vs. 0.78; p = 0.013), 787 nm (median, 0.65 vs. 0.77; p = 0.034), and 853 nm (median, 0.59 vs. 0.85; p = 0.028). The comparison of the normalized PA intensities among cholesterol polyps, adenomas, and adenocarcinomas demonstrated marginally significant differences at 765 nm (median, 0.67 vs. 0.66 vs. 0.78, respectively; p = 0.049). These preliminary results indicate that benign versus malignant gallbladder polyps might exhibit different spectral patterns on multispectral PA imaging

  9. Gamma-ray imaging probes

    International Nuclear Information System (INIS)

    Wild, W.J.

    1988-01-01

    External nuclear medicine diagnostic imaging of early primary and metastatic lung cancer tumors is difficult due to the poor sensitivity and resolution of existing gamma cameras. Nonimaging counting detectors used for internal tumor detection give ambiguous results because distant background variations are difficult to discriminate from neighboring tumor sites. This suggests that an internal imaging nuclear medicine probe, particularly an esophageal probe, may be advantageously used to detect small tumors because of the ability to discriminate against background variations and the capability to get close to sites neighboring the esophagus. The design, theory of operation, preliminary bench tests, characterization of noise behavior and optimization of such an imaging probe is the central theme of this work

  10. Most significant preliminary results of the probabilistic safety analysis on the Juragua nuclear power plant

    International Nuclear Information System (INIS)

    Perdomo, Manuel

    1995-01-01

    Since 1990 the Group for PSA Development and Applications (GDA/APS) is working on the Level-1 PSA for the Juragua-1 NPP, as a part of an IAEA Technical Assistance Project. The main objective of this study, which is still under way, is to assess, in a preliminary way, the Reactor design safety to find its potential 'weak points' at the construction stage, using a eneric data base. At the same time, the study allows the PSA team to familiarize with the plant design and analysis techniques for the future operational PSA of the plant. This paper presents the most significant preliminary results of the study, which reveal some advantages of the safety characteristics of the plant design in comparison with the homologous VVER-440 reactors and some areas, where including slight modifications would improve the plant safety, considering the level of detail at which the study is carried out. (author). 13 refs, 1 fig, 2 tabs

  11. Pathological diagnosis of bladder cancer by image analysis of hypericin induced fluorescence cystoscopic images

    Science.gov (United States)

    Kah, James C. Y.; Olivo, Malini C.; Lau, Weber K. O.; Sheppard, Colin J. R.

    2005-08-01

    Photodynamic diagnosis of bladder carcinoma based on hypericin fluorescence cystoscopy has shown to have a higher degree of sensitivity for the detection of flat bladder carcinoma compared to white light cystoscopy. The potential of the photosensitizer hypericin-induced fluorescence in performing non-invasive optical biopsy to grade bladder cancer in vivo using fluorescence cystoscopic image analysis without surgical resection for tissue biopsy is investigated in this study. The correlation between tissue fluorescence and histopathology of diseased tissue was explored and a diagnostic algorithm based on fluorescence image analysis was developed to classify the bladder cancer without surgical resection for tissue biopsy. Preliminary results suggest a correlation between tissue fluorescence and bladder cancer grade. By combining both the red-to-blue and red-to-green intensity ratios into a 2D scatter plot yields an average sensitivity and specificity of around 70% and 85% respectively for pathological cancer grading of the three different grades of bladder cancer. Therefore, the diagnostic algorithm based on colorimetric intensity ratio analysis of hypericin fluorescence cystoscopic images developed in this preliminary study shows promising potential to optically diagnose and grade bladder cancer in vivo.

  12. 75 FR 4779 - Certain Cut-to-Length Carbon-Quality Steel Plate Products From Italy: Preliminary Results of...

    Science.gov (United States)

    2010-01-29

    ...-Quality Steel Plate Products From Italy: Preliminary Results of Antidumping Duty Administrative Review... administrative review of the antidumping duty order on certain cut-to-length carbon- quality steel plate products... that the Department conduct an administrative review of its sales and entries of subject merchandise...

  13. 75 FR 4044 - Stainless Steel Bar From Brazil: Extension of Time Limit for Preliminary Results of Antidumping...

    Science.gov (United States)

    2010-01-26

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-351-825] Stainless Steel Bar From... antidumping duty order on certain stainless steel bar from Brazil for the period February 1, 2008, through... Steel Bar From Brazil: Extension of Time Limit for Preliminary Results of Antidumping Duty...

  14. 77 FR 11485 - Certain Pasta From Turkey: Extension of Time Limit for the Preliminary Results of Antidumping...

    Science.gov (United States)

    2012-02-27

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-489-805] Certain Pasta From Turkey: Extension of Time Limit for the Preliminary Results of Antidumping Duty Administrative Review AGENCY: Import... initiation of the administrative review of the antidumping duty order on certain pasta from Turkey, covering...

  15. 75 FR 81218 - Laminated Woven Sacks From the People's Republic of China: Preliminary Results of the Second...

    Science.gov (United States)

    2010-12-27

    ... the People's Republic of China: Preliminary Results of the Second Administrative Review AGENCY: Import... laminated woven sacks (``LWS'') from the People's Republic of China (``PRC'') covering the period August 1, 2009, through July 31, 2010. This review covers imports of subject merchandise from one manufacturer...

  16. 77 FR 46030 - Pure Magnesium in Granular Form From the People's Republic of China: Preliminary Results of...

    Science.gov (United States)

    2012-08-02

    ... granular magnesium'') from the People's Republic of China (``PRC'') with respect to one producer/ exporter... Form From the People's Republic of China: Preliminary Results of Antidumping Duty Administrative Review...-2012 Administrative Review of Pure Magnesium in Granular Form from the People's Republic of China...

  17. 76 FR 13358 - Persulfates From the People's Republic of China: Preliminary Results of the 2009-2010 Antidumping...

    Science.gov (United States)

    2011-03-11

    ...'s Republic of China: Preliminary Results of the 2009-2010 Antidumping Duty Administrative Review... conducting an administrative review of the antidumping duty order on persulfates from the People's Republic... review covers one producer/exporter of the subject merchandise, i.e., United Initiators (Shanghai) Co...

  18. 76 FR 33194 - Pure Magnesium From the People's Republic of China: Preliminary Results of the 2009-2010...

    Science.gov (United States)

    2011-06-08

    ... assessment rates are above de minimis. We invite interested parties to comment on these preliminary results... Determination of Sales at Less Than Fair Value: Antidumping Duty Investigation of Pure Magnesium From the... the following alloying elements: aluminum, manganese, zinc, silicon, thorium, zirconium and rare...

  19. 78 FR 69820 - Seamless Refined Copper Pipe and Tube From the People's Republic of China: Preliminary Results...

    Science.gov (United States)

    2013-11-21

    ...\\ \\1\\ See Seamless Refined Copper Pipe and Tube From Mexico and the People's Republic of China... and Tube From the People's Republic of China: Preliminary Results and Partial Rescission of... China (``PRC''), covering the period November 1, 2011 through October 31, 2012. The Department has...

  20. Resting-state functional magnetic resonance imaging for surgical planning in pediatric patients: a preliminary experience.

    Science.gov (United States)

    Roland, Jarod L; Griffin, Natalie; Hacker, Carl D; Vellimana, Ananth K; Akbari, S Hassan; Shimony, Joshua S; Smyth, Matthew D; Leuthardt, Eric C; Limbrick, David D

    2017-12-01

    OBJECTIVE Cerebral mapping for surgical planning and operative guidance is a challenging task in neurosurgery. Pediatric patients are often poor candidates for many modern mapping techniques because of inability to cooperate due to their immature age, cognitive deficits, or other factors. Resting-state functional MRI (rs-fMRI) is uniquely suited to benefit pediatric patients because it is inherently noninvasive and does not require task performance or significant cooperation. Recent advances in the field have made mapping cerebral networks possible on an individual basis for use in clinical decision making. The authors present their initial experience translating rs-fMRI into clinical practice for surgical planning in pediatric patients. METHODS The authors retrospectively reviewed cases in which the rs-fMRI analysis technique was used prior to craniotomy in pediatric patients undergoing surgery in their institution. Resting-state analysis was performed using a previously trained machine-learning algorithm for identification of resting-state networks on an individual basis. Network maps were uploaded to the clinical imaging and surgical navigation systems. Patient demographic and clinical characteristics, including need for sedation during imaging and use of task-based fMRI, were also recorded. RESULTS Twenty patients underwent rs-fMRI prior to craniotomy between December 2013 and June 2016. Their ages ranged from 1.9 to 18.4 years, and 12 were male. Five of the 20 patients also underwent task-based fMRI and one underwent awake craniotomy. Six patients required sedation to tolerate MRI acquisition, including resting-state sequences. Exemplar cases are presented including anatomical and resting-state functional imaging. CONCLUSIONS Resting-state fMRI is a rapidly advancing field of study allowing for whole brain analysis by a noninvasive modality. It is applicable to a wide range of patients and effective even under general anesthesia. The nature of resting

  1. The Agricultural Model Intercomparison and Improvement Project (AgMIP): Progress and Preliminary Results

    Science.gov (United States)

    Rosenzweig, C.

    2011-12-01

    The Agricultural Model Intercomparison and Improvement Project (AgMIP) is a distributed climate-scenario simulation exercise for historical model intercomparison and future climate change conditions with participation of multiple crop and agricultural trade modeling groups around the world. The goals of AgMIP are to improve substantially the characterization of risk of hunger and world food security due to climate change and to enhance adaptation capacity in both developing and developed countries. Recent progress and the current status of AgMIP will be presented, highlighting three areas of activity: preliminary results from crop pilot studies, outcomes from regional workshops, and emerging scientific challenges. AgMIP crop modeling efforts are being led by pilot studies, which have been established for wheat, maize, rice, and sugarcane. These crop-specific initiatives have proven instrumental in testing and contributing to AgMIP protocols, as well as creating preliminary results for aggregation and input to agricultural trade models. Regional workshops are being held to encourage collaborations and set research activities in motion for key agricultural areas. The first of these workshops was hosted by Embrapa and UNICAMP and held in Campinas, Brazil. Outcomes from this meeting have informed crop modeling research activities within South America, AgMIP protocols, and future regional workshops. Several scientific challenges have emerged and are currently being addressed by AgMIP researchers. Areas of particular interest include geospatial weather generation, ensemble methods for climate scenarios and crop models, spatial aggregation of field-scale yields to regional and global production, and characterization of future changes in climate variability.

  2. Recent improvements in the calculation of prompt fission neutron spectra: Preliminary results

    International Nuclear Information System (INIS)

    Madland, D.G.; LaBauve, R.J.; Nix, J.R.

    1989-01-01

    We consider three topics in the refinement and improvement of our original calculations of prompt fission neutron spectra. These are an improved calculation of the prompt fission neutron spectrum N(E) from the spontaneous fission of 252 Cf, a complete calculation of the prompt fission neutron spectrum matrix N(E,E n ) from the neutron-induced fission of 235 U, at incident neutron energies ranging from 0 to 15 MeV, and an assessment of the scission neutron component of the prompt fission neutron spectrum. Preliminary results will be presented and compared with experimental measurements and an evaluation. A suggestion is made for new integral cross section measurements. (author). 45 refs, 12 figs, 1 tab

  3. Preliminary study on X-ray phase contrast imaging using synchrotron radiation facility

    International Nuclear Information System (INIS)

    Xiong Zhuang; Wang Jianhua; Yu Yongqiang; Jiang Shiping; Chen Yang; Tian Yulian

    2006-01-01

    Objective: To study the methodology of X-ray phase contrast imaging using synchrotron radiation, and evaluate the quality of phase contrast images. Methods: Several experiments to obtain phase contrast images and absorption contrast images of various biological samples were conducted in Beijing Synchrotron Radiation Facility (BSRF), and then these images were interpreted to find out the difference between the two kinds of imaging methods. Results: Satisfactory phase contrast images of these various samples were obtained, and the quality of these images was superior to that obtained with absorption contrast imaging. The phase contrast formation is based on the phenomenon of fresnel diffraction which transforms phase shifts into intensity variations upon a simple act of free-space propagation, so it requires highly coherent X-rays and appropriate distance between sample and detector. This method of imaging is very useful in imaging of low-absorption objects or objects with little absorption variation, and its resolution is far higher than that of the conventional X-ray imaging. The photographs obtained showed very fine inner microstructure of the biological samples, and the smallest microstructure to be distinguished is within 30-40 μm. There is no doubt that phase contrast imaging has a practical applicability in medicine. Moreover, it improves greatly the efficiency and the resolution of the existing X-ray diagnostic techniques. Conclusions: X-ray phase contrast imaging can be performed with synchrotron radiation source and has some advantages over the conventional absorption contrast imaging. (authors)

  4. Preliminary results for the helicity asymmetry E for eta photoproduction on the proton

    International Nuclear Information System (INIS)

    2012-01-01

    Polarization observables are an important tool for clarifying the nucleon resonance spectrum. No previous measurements for double polarization asymmetries have been published for eta photoproduction. Double polarization measurements have been made at Jefferson Lab using a polarized photon beam and protons in a polarized frozen spin target (FROST). Data were taken during the first running period of FROST using the CLAS detector with photon energies from 0.33 to 2.35 GeV. Preliminary results for the E polarization observable for eta meson photoproduction from the proton at threshold and above, along with comparisons to several theoretical predictions are presented.

  5. Postmortem study of stable carbon isotope ratios in human cerebellar DNA: preliminary results

    International Nuclear Information System (INIS)

    Slatkin, D.N.; Irsa, A.P.; Friedman, L.

    1978-01-01

    It is observed that 13 C/ 12 C ratios in tissue specimens removed postmortem in the United States and Canada are significantly different from corresponding ratios in European specimens. On the basis of this information, measurements of carbon isotope ratios in DNA isolated from cerebella of native-born and European-born North Americans are in progress with the goal of estimating the average lifetime rate of DNA turnover in human neurons. Preliminary results from twenty postmortem examinations are consistent with the hypothesis that a significant proportion of human cerebellar DNA is renewed during the lifetime of an individual

  6. 76 FR 17380 - Solid Urea From the Russian Federation: Extension of Time Limit for Preliminary Results of...

    Science.gov (United States)

    2011-03-29

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-821-801] Solid Urea From the Russian Federation: Extension of Time Limit for Preliminary Results of Antidumping Duty Administrative Review AGENCY... administrative review of the antidumping duty order on solid urea from the Russian Federation for the period July...

  7. 75 FR 13495 - Saccharin from the People's Republic of China: Preliminary Results of the 2008-2009 Antidumping...

    Science.gov (United States)

    2010-03-22

    ... Republic of China: Preliminary Results of the 2008-2009 Antidumping Duty Administrative Review AGENCY... administrative review of the antidumping duty order on saccharin from the People's Republic of China (``PRC'') covering the period July 1, 2008, through June 30, 2009. This administrative review covers one exporter of...

  8. A device for multimodal imaging of skin

    Science.gov (United States)

    Spigulis, Janis; Garancis, Valerijs; Rubins, Uldis; Zaharans, Eriks; Zaharans, Janis; Elste, Liene

    2013-03-01

    A compact prototype device for diagnostic imaging of skin has been developed and tested. Polarized LED light at several spectral regions is used for illumination, and round skin spot of diameter 30mm is imaged by a CMOS sensor via crossoriented polarizing filter. Four consecutive imaging series are performed: (1) RGB image at white LED illumination for revealing subcutaneous structures; (2) four spectral images at narrowband LED illumination (450nm, 540nm, 660nm, 940nm) for mapping of the main skin chromophores; (3) video-imaging under green LED illumination for mapping of skin blood perfusion; (4) autofluorescence video-imaging under UV (365nm) LED irradiation for mapping of the skin fluorophores. Design details of the device as well as preliminary results of clinical tests are presented.

  9. Preliminary results from initial in-pile debris bed experiments

    International Nuclear Information System (INIS)

    Rivard, J.B.

    1977-01-01

    An accident in a liquid metal fast breeder reactor (LMFBR) in which molten core material is suddenly quenched with subcooled liquid sodium could result in extensive fragmentation and dispersal of fuel as subcritical beds of frozen particulate debris within the reactor vessel. Since this debris will continue to generate power due to decay of retained fission products, containment of the debris is threatened if the generated heat is not removed. Therefore, the initial safety question is the capacity which debris beds may have for transfer of the decay heat to overlying liquid sodium by natural processes--i.e., without the aid of forced circulation of the coolant. Up to the present time, all experiments on debris bed behavior either have used substitute materials (e.g., sand and water) or have employed actual materials, but atypical heating methods. Increased confidence in the applicability of debris bed simulations is afforded if the heat is generated within the fuel component of the appropriate fast reactor materials. The initial series of in-pile tests reported on herein constitutes the first experiments in which the internal heating mode has been produced in particulate oxide fuel immersed in liquid sodium. Fission heating of the fully-enriched UO 2 in the experiment while it is contained within Sandia Laboratories Annular Core Pulse Reactor (ACPR), operating in its steady-state mode, approximates the decay heating of debris. Preliminary results are discussed

  10. The Myres Hill remote sensing intercomparison study: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Clive, P J M; Chindurza, I [SgurrEnergy Ltd, 79 Coplaw Street, Glasgow G42 7JG, Scotland (United Kingdom); Ravey, I; Bass, J [RES Group Ltd, James Blyth House, 7000 Academy Park, Glasgow, Scotland (United Kingdom); Boyle, R J; Jones, P [TUV NEL Ltd, East Kilbride, Glasgow G75 0QF, Scotland (United Kingdom); Lang, S J [Sustainable Energy Research Group, University College Cork (Ireland); Bradley, S [Mighty River Power, Level 14, 23-29 Albert Street, Auckland (New Zealand); Hay, L [Garrad Hassan and Partners Ltd, 2064 Maryhill Road, Glasgow G20 0AB, Scotland (United Kingdom); Oldroyd, A [Oldbaum Services Ltd, Schoolhouse, Brig o' Turk, Callander, Scotland (United Kingdom); Stickland, M [University of Strathclyde, 16 Richmond Street, Glasgow G1 1XQ, Scotland (United Kingdom)], E-mail: peter.clive@sgurrenergy.com

    2008-05-01

    Two remote sensing techniques (SODAR and LIDAR) have been developed for measuring wind speed and turbulence from ground level up to altitudes of 300 m or higher. Although originally developed in the defence sector, these techniques are now generating considerable interest in the renewable energy and meteorological sectors. Despite the benefits of these instruments they are not yet generally accepted for due diligence measurements by wind energy developers and financial institutions. There is a requirement for a series of independent assessments of these new metrology techniques, comparing their measurements with the approved cup-type anemometer readings. This is being addressed at TUV NEL's Myres Hill wind turbine test site in a measurement programme supported by the DIUS National Measurement Systems Measurement for Innovators scheme and a consortium of 21 industrial collaborators. Data from SODAR and LIDAR systems are being compared with results from cup-type anemometers mounted at different heights on an 80m meteorological mast. An ultrasonic sensor is also mounted on the mast. The objective of the test programme is to assess the effectiveness of SODAR and LIDAR wind speed measurement techniques under different operating regimes and atmospheric conditions. Results from the measurements will provide definitive data on the performance of the remote wind speed sensing techniques under test on complex terrain typical of many wind farm sites. Preliminary measurements based on data acquired during the initial measurement campaign are presented.

  11. Preliminary study on X-ray fluorescence computed tomography imaging of gold nanoparticles: Acceleration of data acquisition by multiple pinholes scheme

    Science.gov (United States)

    Sasaya, Tenta; Sunaguchi, Naoki; Seo, Seung-Jum; Hyodo, Kazuyuki; Zeniya, Tsutomu; Kim, Jong-Ki; Yuasa, Tetsuya

    2018-04-01

    Gold nanoparticles (GNPs) have recently attracted attention in nanomedicine as novel contrast agents for cancer imaging. A decisive tomographic imaging technique has not yet been established to depict the 3-D distribution of GNPs in an object. An imaging technique known as pinhole-based X-ray fluorescence computed tomography (XFCT) is a promising method that can be used to reconstruct the distribution of GNPs from the X-ray fluorescence emitted by GNPs. We address the acceleration of data acquisition in pinhole-based XFCT for preclinical use using a multiple pinhole scheme. In this scheme, multiple projections are simultaneously acquired through a multi-pinhole collimator with a 2-D detector and full-field volumetric beam to enhance the signal-to-noise ratio of the projections; this enables fast data acquisition. To demonstrate the efficacy of this method, we performed an imaging experiment using a physical phantom with an actual multi-pinhole XFCT system that was constructed using the beamline AR-NE7A at KEK. The preliminary study showed that the multi-pinhole XFCT achieved a data acquisition time of 20 min at a theoretical detection limit of approximately 0.1 Au mg/ml and at a spatial resolution of 0.4 mm.

  12. Results from the coded aperture neutron imaging system

    International Nuclear Information System (INIS)

    Brubaker, Erik; Steele, John T.; Brennan, James S.; Marleau, Peter

    2010-01-01

    Because of their penetrating power, energetic neutrons and gamma rays (∼1 MeV) offer the best possibility of detecting highly shielded or distant special nuclear material (SNM). Of these, fast neutrons offer the greatest advantage due to their very low and well understood natural background. We are investigating a new approach to fast-neutron imaging - a coded aperture neutron imaging system (CANIS). Coded aperture neutron imaging should offer a highly efficient solution for improved detection speed, range, and sensitivity. We have demonstrated fast neutron and gamma ray imaging with several different configurations of coded masks patterns and detectors including an 'active' mask that is composed of neutron detectors. Here we describe our prototype detector and present some initial results from laboratory tests and demonstrations.

  13. Hybridization among wild boars, local breeds and commercial breeds - preliminary results

    DEFF Research Database (Denmark)

    Iacolina, Laura; Bakan, Jana; Cubric-Curik, Vlatka

    . Hybridization with the domestic pig is known to occur in Europe, however the degree and extent of the phenomenon is not fully understood yet. Introgression is considered to be a treat to biodiversity and could lead to loss of local adaptation or introgression in the wild population of human selected genes....... A better understanding of the hybridization levels at European scale would provide an important tool for the development of management plans aimed at reducing human conflict but also at preserving biodiversity and genetic differentiation. Additionally, this information would provide new perspectives...... gradients in variability levels among the analysed wild and domestic populations. This preliminary results will be further investigated to address the possible presence of hybrid zone(s) in Europe and the possible implications for conservation and management of both wild populations and local pig breeds...

  14. High-resolution MR imaging of the elbow using a microscopy surface coil and a clinical 1.5 T MR machine: preliminary results

    International Nuclear Information System (INIS)

    Yoshioka, Hiroshi; Ueno, Teruko; Takahashi, Nobuyuki; Saida, Yukihisa; Tanaka, Toshikazu; Kujiraoka, Yuka; Shindo, Masashi; Nishiura, Yasumasa; Ochiai, Naoyuki

    2004-01-01

    To obtain high-resolution MR images of the elbow using a microscopy surface coil with a 1.5 T clinical machine and to evaluate the feasibility of its use for elbow injuries. Five asymptomatic normal volunteers and 13 patients with elbow pain were prospectively studied with MR imaging using a microscopy surface coil 47 mm in diameter. High-resolution MR images using a microscopy coil were obtained with fast spin echo (FSE) proton density-weighted sequence, gradient recalled echo (GRE) T2*-weighted sequence, and short tau inversion recovery (STIR) sequence, with a 1-2 mm slice thickness, a 50-70 mm field of view, an imaging matrix of 140-224 x 512 using zero fill interpolation, and 2-6 excitations. High-resolution MR images of normal volunteers using a microscopy coil clearly showed each structure of the medial and lateral collateral ligaments on GRE T2*-weighted images and FSE proton-density weighted images. Partial medial collateral ligament injury, a small avulsion of the medial epicondyle, and osteochondritis dissecans were well demonstrated on high-resolution MR images. High-resolution MR imaging of the elbow using a microscopy surface coil with a 1.5 T clinical machine is a promising method for accurately characterizing the normal anatomy of the elbow and depicting its lesions in detail. (orig.)

  15. Preliminary results of the XR2-1 experiment

    International Nuclear Information System (INIS)

    Gauntt, R.O.; Helmick, P.H.; Humphries, L.

    1996-01-01

    The XR2-1 (Ex-Reactor) experiment, investigating metallic core-melt relocation in boiling water reactor geometry, was performed on October 12, 1995, following two previous simpler XR1-series tests in August and November of 1993. The XR2-1 test made use of a highly detailed replication of the lower region of the BWR core, including the control blade and channel box structures, fuel rods, fuel canister nosepieces, control blade velocity limiter, and fuel support pieces, in order to investigate a key core melt progression uncertainty for BWR Station Blackout type accidents. The purpose of this experiment program is to examine the behavior of downward-draining molten metallic core materials in a severe reactor accident in a dry BWR core, and to determine conditions under which the molten materials drain out of the core region, or freeze to form blockages in the lower portion of the core. In the event that the draining metallic materials do not form stable blockages in the lower core region, and instead erode the lower core structures such as the lower core plate, then the subsequent core melt progression processes may proceed quite differently than was observed in the TMI-2 accident, with correspondingly different impact on vessel loading and vessel release behavior. The results of the Ex-Reactor tests are preliminary. All of the tests conducted have shown a significant degree of channel box destruction induced by the draining control blade materials. The XR2-1 test further showed that the draining zircaloy melt causes significant disruption of the fuel rod geometry. All of the tests have shown tendencies to form interim blockages as the melts temporarily freeze, but that these blockages re-melt, assisted by eutectic interactions, resulting in the sudden draining of accumulated metallic melt pools

  16. Preliminary results of hydrologic testing: The composite Umtanum basalt flow top at borehole RRL-2 (3,568 - 3,781 feet)

    International Nuclear Information System (INIS)

    Strait, S.R.; Spane, F.A. Jr.

    1982-11-01

    This report presents preliminary results and description of hydrologic test activities for the composite Umtanum basalt flow top (3,568--3,781 feet) at Borehole RRL-2. Hydrologic tests conducted include two constant discharge air-lift and four slug tests. Preliminary results indicate an observed hydraulic head for the test interval of 405.7 feet above mean sea level. Transmissivity values determined from hydrologic tests performed, range between 244 to 481 ft 2 /day, with an assigned best estimate of 480 ft 2 /day. The best estimate of equivalent hydraulic conductivity, based on an effective test thickness of 157 feet, is 3.1 ft/day. 7 refs., 9 figs., 3 tabs

  17. Preliminary Results from the PrimEx-II experiment at Jefferson Lab

    Energy Technology Data Exchange (ETDEWEB)

    Gasparian, Ashot [NCA& T, Greensboro, NC; Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2016-06-01

    Properties of the neutral pion, as the lightest hadron in Nature, are most sensitive to the basic symmetries and their partial breaking effects in the theory of the strong interaction (QCD). In particular, the po →gg decay width is primarily defined by the spontaneous chiral symmetry breaking effect (chiral anomaly) in QCD. The next order corrections to the anomaly have been shown to be small and are known to a 1% precision level. The PrimEx Collaboration at JLab has developed and performed two Primakoff type experiments to measure the po →gg decay width with a similar precision. The published result from the PrimEx-I experiment, G(p0 →gg ) = 7.82±0.14 (stat.)±0.17 (syst.) eV, was a factor of two more precise than the average value quoted in PDG-2010 [1]. The second experiment was performed in 2010 with a goal of 1.4% total uncertainty to address the next-to-leading-order theory calculations. The preliminary results from the PrimEx-II experiment are presented and discussed in this note.

  18. Research Initiatives and Preliminary Results In Automation Design In Airspace Management in Free Flight

    Science.gov (United States)

    Corker, Kevin; Lebacqz, J. Victor (Technical Monitor)

    1997-01-01

    The NASA and the FAA have entered into a joint venture to explore, define, design and implement a new airspace management operating concept. The fundamental premise of that concept is that technologies and procedures need to be developed for flight deck and ground operations to improve the efficiency, the predictability, the flexibility and the safety of airspace management and operations. To that end NASA Ames has undertaken an initial development and exploration of "key concepts" in the free flight airspace management technology development. Human Factors issues in automation aiding design, coupled aiding systems between air and ground, communication protocols in distributed decision making, and analytic techniques for definition of concepts of airspace density and operator cognitive load have been undertaken. This paper reports the progress of these efforts, which are not intended to definitively solve the many evolving issues of design for future ATM systems, but to provide preliminary results to chart the parameters of performance and the topology of the analytic effort required. The preliminary research in provision of cockpit display of traffic information, dynamic density definition, distributed decision making, situation awareness models and human performance models is discussed as they focus on the theme of "design requirements".

  19. Development of methods to measure hemoglobin adducts by gel electrophoresis - Preliminary results

    International Nuclear Information System (INIS)

    Sun, J.D.; McBride, S.M.

    1988-01-01

    Chemical adducts formed on blood hemoglobin may be a useful biomarker for assessing human exposures to these compounds. This paper reports preliminary results in the development of methods to measure such adducts that may be generally applicable for a wide variety of chemicals. Male F344/N rats were intraperitoneally injected with 14 C-BaP dissolved in corn oil. Twenty-four hours later, the rats were sacrificed. Blood samples were collected and globin was isolated. Globin protein was then cleaved into peptide fragments using cyanogen bromide and the fragments separated using 2-dimensional gel electrophoresis. The results showed that the adducted 14 C-globin fragments migrated to different areas of the gel than did unadducted fragments. Further research is being conducted to develop methods that will allow quantitation of separated adducted globin fragments from human blood samples without the use of a radiolabel. (author)

  20. New cysteamine (2-chloroethyl)nitrosoureas. Synthesis and preliminary antitumor results.

    Science.gov (United States)

    Madelmont, J C; Godeneche, D; Parry, D; Duprat, J; Chabard, J L; Plagne, R; Mathe, G; Meyniel, G

    1985-09-01

    Three chemical pathways were used for the synthesis of four new N'-(2-chloroethyl)-N-[2-(methylsulfinyl)ethyl]- and N'-(2-chloroethyl)-N-[2-(methylsulfonyl)ethyl]-N- or N'-nitrosoureas. These compounds are plasma metabolites of CNCC, a promising antineoplastic (2-chloroethyl)nitrosourea. Preliminary antitumor evaluation was performed against L1210 leukemia implanted intraperitoneally in mice. Among these compounds, two of them exhibited a greater antitumor activity compared to that of the parent mixture.

  1. 77 FR 73417 - Diamond Sawblades and Parts Thereof From the People's Republic of China: Preliminary Results of...

    Science.gov (United States)

    2012-12-10

    ... Thereof From the People's Republic of China: Preliminary Results of Antidumping Duty Administrative Review... Republic of China (``PRC''). The period of review (``POR'') is November 1, 2010 through October 31, 2011... have been calculated in accordance with section 772 of the Act. Because the PRC is a nonmarket economy...

  2. 77 FR 73015 - Circular Welded Non-Alloy Steel Pipe From the Republic of Korea: Preliminary Results of...

    Science.gov (United States)

    2012-12-07

    ... Steel Pipe From the Republic of Korea: Preliminary Results of Antidumping Duty Administrative Review... antidumping duty order on circular welded non-alloy steel pipe (CWP) from the Republic of Korea (Korea). The... preliminarily found that one respondent has made sales of the subject merchandise at prices below normal value...

  3. Results of preliminary experiments on tritium decontamination by UV irradiation

    International Nuclear Information System (INIS)

    Oya, Yasuhisa; Shu, Wataru; O'hira, Shigeru; Hayashi, Takumi; Nishi, Masataka

    2000-03-01

    In the point of view of protection of workers from the radiation exposure and the limitation of the contamination with radioactive materials, it is important to decontaminate mobile tritium from plasma facing components of a nuclear fusion reactor at the beginning of their maintenance work. It is considered that the heating is the most effective method for decontamination. However, it is important to develop new decontamination method of adsorbed hydro-carbon based substances from the materials that cannot be heated or the inner pipe of double pipes. This report presents results of preliminary experiments performed for the development of the effective tritium decontamination technique pursuing under US/Japan collaborative program on technology for fusion-fuel processing (Annex IV). In the experiments, the effects of Ultra Violet (UV) irradiation on tritium removal from some kinds of materials, such as poly vinyl chloride -(CH 2 CHCl) n - film, polyethylene film and graphite samples coated by C 2 H 2 plasma were examined. As the result of UV irradiation, it was confined that hydrogen and carbon based compounds could be released from the specimen during UV irradiation. It is concluded that UV irradiation is one of the hopeful candidates for effective tritium decontamination. (author)

  4. Some results of automatic processing of images

    International Nuclear Information System (INIS)

    Golenishchev, I.A.; Gracheva, T.N.; Khardikov, S.V.

    1975-01-01

    The problems of automatic deciphering of the radiographic picture the purpose of which is making a conclusion concerning the quality of the inspected product on the basis of the product defect images in the picture are considered. The methods of defect image recognition are listed, and the algorithms and the class features of defects are described. The results of deciphering of a small radiographic picture by means of the ''Minsk-22'' computer are presented. It is established that the sensitivity of the method of the automatic deciphering is close to that obtained for visual deciphering

  5. IRIS PRA preliminary results and future direction

    International Nuclear Information System (INIS)

    Finnicum, D.J.; Kling, C.L.; Carelli, M.D.

    2004-01-01

    Westinghouse is currently conducting the pre-application licensing of the International Reactor Innovative and Secure (IRIS) on behalf of the IRIS Consortium. One of the key aspects of the IRIS design is the concept of safety-by-design. The PRA (Probabilistic Risk Analysis) is being used as an integral part of the design process. As part of this effort, a PRA of the initial design was generated to address 2 key areas. First, the IRIS PRA supported the evaluation of IRIS design issues by providing a solid risk basis for design and analyses required for the pre-licensing evaluation of the IRIS design. The PRA provides the tool for quantifying the benefit of the safety-by-design approach. Second, the current PRA task is beginning the preparation of the more complete PRA analyses and documentation eventually required for Design Certification. One of the key risk-related goals for IRIS is to reduce the EPZ (Emergency Protection Zone) to within the exclusion area by demonstrating that the off-site doses are consistent with the US Protective Action Guidelines (PAGs) for initiation of emergency response so that the required protective actions would be limited to the exclusion area. The results of the preliminary PRA indicated a core damage frequency of 1.2 E-08 for internal initiators. This is a very good result but much work is needed to meet the ambitious goal of no emergency response. The next phase of the PRA analyses will involve a two-fold expansion of the PRA. First, as the design and analyses approach a greater level of detail, the assumptions used for the initial PRA will be reviewed and the models will be revised as needed to reflect the improved knowledge of the system design and performance. Furthermore, as the full plant design advances, the PRA will be expanded to incorporate risk associated with external challenges such as seismic and fire, and to address low power and shutdowns modes of operation. As with the initial work, the PRA will serve as a tool to

  6. A combination of preliminary results on gauge boson couplings measured by the LEP Experiments

    CERN Document Server

    CERN. Geneva

    2004-01-01

    This note presents a combination of published and preliminary measurements of triple gauge boson couplings (TGCs) and quartic gauge boson couplings (QGCs) from the four LEP experiments. We give an updated combination of the charged TGCs, g1z, kg and lg in single and multi-parameter fits. Updated results from the QGCs from the ZZgg vertex, ac/Lambda^2 and a0/Lambda^2, are given as well. The combinations of neutral TGCs hiv anf fiv are also presented, including an updated fiv combination.

  7. Modeling of Particle Acceleration at Multiple Shocks Via Diffusive Shock Acceleration: Preliminary Results

    Science.gov (United States)

    Parker, L. N.; Zank, G. P.

    2013-12-01

    Successful forecasting of energetic particle events in space weather models require algorithms for correctly predicting the spectrum of ions accelerated from a background population of charged particles. We present preliminary results from a model that diffusively accelerates particles at multiple shocks. Our basic approach is related to box models (Protheroe and Stanev, 1998; Moraal and Axford, 1983; Ball and Kirk, 1992; Drury et al., 1999) in which a distribution of particles is diffusively accelerated inside the box while simultaneously experiencing decompression through adiabatic expansion and losses from the convection and diffusion of particles outside the box (Melrose and Pope, 1993; Zank et al., 2000). We adiabatically decompress the accelerated particle distribution between each shock by either the method explored in Melrose and Pope (1993) and Pope and Melrose (1994) or by the approach set forth in Zank et al. (2000) where we solve the transport equation by a method analogous to operator splitting. The second method incorporates the additional loss terms of convection and diffusion and allows for the use of a variable time between shocks. We use a maximum injection energy (Emax) appropriate for quasi-parallel and quasi-perpendicular shocks (Zank et al., 2000, 2006; Dosch and Shalchi, 2010) and provide a preliminary application of the diffusive acceleration of particles by multiple shocks with frequencies appropriate for solar maximum (i.e., a non-Markovian process).

  8. Rayleigh to Compton ratio scatter tomography applied to breast cancer diagnosis: A preliminary computational study

    International Nuclear Information System (INIS)

    Antoniassi, M.; Conceição, A.L.C.; Poletti, M.E.

    2014-01-01

    In the present work, a tomographic technique based on Rayleigh to Compton scattering ratio (R/C) was studied using computational simulation in order to assess its application to breast cancer diagnosis. In this preliminary study, some parameters that affect the image quality were evaluated, such as: (i) energy beam, (ii) size and glandularity of the breast, and (iii) statistical count noise. The results showed that the R/C contrast increases with increasing photon energy and decreases with increasing glandularity of the sample. The statistical noise showed to be a significant parameter, although the quality of the obtained images was acceptable for a considerable range of noise level. The preliminary results suggest that the R/C tomographic technique has a potential of being applied as a complementary tool in the breast cancer diagnostic. - Highlights: ► A tomographic technique based on Rayleigh to Compton scattering ratio is proposed in order to study breast tissues. ► The Rayleigh to Compton scattering ratio technique is compared with conventional transmission technique. ► The influence of experimental parameters (energy, sample, detection system) is studied

  9. Artificial Intelligence In Processing A Sequence Of Time-Varying Images

    Science.gov (United States)

    Siler, W.; Tucker, D.; Buckley, J.; Hess, R. G.; Powell, V. G.

    1985-04-01

    A computer system is described for unsupervised analysis of five sets of ultrasound images of the heart. Each set consists of 24 frames taken at 33 millisecond intervals. The images are acquired in real time with computer control of the ultrasound apparatus. After acquisition the images are segmented by a sequence of image-processing programs; features are extracted and stored in a version of the Carnegie- Mellon Blackboard. Region classification is accomplished by a fuzzy logic expert system FLOPS based on OPS5. Preliminary results are given.

  10. Reducing the uncertainty in the fidelity of seismic imaging results

    Science.gov (United States)

    Zhou, H. W.; Zou, Z.

    2017-12-01

    A key aspect in geoscientific inversion is quantifying the quality of the results. In seismic imaging, we must quantify the uncertainty of every imaging result based on field data, because data noise and methodology limitations may produce artifacts. Detection of artifacts is therefore an important aspect in uncertainty quantification in geoscientific inversion. Quantifying the uncertainty of seismic imaging solutions means assessing their fidelity, which defines the truthfulness of the imaged targets in terms of their resolution, position error and artifact. Key challenges to achieving the fidelity of seismic imaging include: (1) Difficulty to tell signal from artifact and noise; (2) Limitations in signal-to-noise ratio and seismic illumination; and (3) The multi-scale nature of the data space and model space. Most seismic imaging studies of the Earth's crust and mantle have employed inversion or modeling approaches. Though they are in opposite directions of mapping between the data space and model space, both inversion and modeling seek the best model to minimize the misfit in the data space, which unfortunately is not the output space. The fact that the selection and uncertainty of the output model are not judged in the output space has exacerbated the nonuniqueness problem for inversion and modeling. In contrast, the practice in exploration seismology has long established a two-fold approach of seismic imaging: Using velocity modeling building to establish the long-wavelength reference velocity models, and using seismic migration to map the short-wavelength reflectivity structures. Most interestingly, seismic migration maps the data into an output space called imaging space, where the output reflection images of the subsurface are formed based on an imaging condition. A good example is the reverse time migration, which seeks the reflectivity image as the best fit in the image space between the extrapolation of time-reversed waveform data and the prediction

  11. Spatial and temporal variation of radiocarbon in tree rings - some preliminary results

    International Nuclear Information System (INIS)

    Higham, T.F.G.; Hogg, A.G.; McCormac, F.G.; Baillie, M.G.L.; Brown, D.; Palmer, J.G.; Xiong, L.

    1997-01-01

    A number of researchers have identified a measurable difference between the 14 C activities of tree rings of identical dendochronological age between the Northern and the Southern Hemispheres. It is also acknowledged that there is an urgent need for new high precision Δ 14 C data from tree rings in both Hemispheres to help resolve the questions relating to the magnitude and cause of the locality and temporal dependence of the Δ 14 C record, to provide a reliable Southern Hemisphere calibration curve and to throw light upon the 1986 and 1993 Calibration data set discrepancies. In this paper, the authors present the research design of a project to investigate these critical issues in radiocarbon age calibration and describe the preliminary results

  12. Contribution of diffusion-weighted MR imaging in follow-up of inflammatory appendiceal mass: Preliminary results and review of the literature

    International Nuclear Information System (INIS)

    Özdemir, Oğuzhan; Metin, Yavuz; Metin, Nurgül Orhan; Küpeli, Ali; Kalcan, Süleyman; Taşçı, Filiz

    2016-01-01

    We aimed to search the contribution of diffusion-weighted imaging (DWI) in follow-up of patients with acute appendicitis associated inflammatory appendiceal mass (IAM). DWI was used as a monitoring imaging method to assess the response of medical treatment. 19 patients (mean age, 37+–13.1; age range, 19–69; M/F: 10/9), presented with clinical, laboratory and computed tomography (CT) findings suggestive of IAM were enrolled prospectively in this study. CT and DWI images were evaluated by two radiologists in consensus. b values 0, 500 and 1000 s/mm 2 were used, and DWI images were analysed both qualitatively and quantitatively. Laboratory parameters were C-reactive protein value and white blood cell count. During follow-up changes in the diameter of IMA and laboratory parameters were correlated with ADC values. Conservative treatment with interval appendectomy and a total conservative approach without surgery were the treatment options during follow-up. We found statistically significant correlation between the ADC values, maximum IAM diameter and laboratory parameters. During follow-up five surgical procedures were performed: one patient underwent surgery for cecal adenocarcinoma and four underwent interval appendectomy. One patient developed acute relapse of IAM at the sixth month of follow-up. DWI may be used with a significant success for follow-up of patients with IAM. As a monitoring imaging method, DWI may also aid in determining of most appropriate timing for interval appendectomy as well as may help in diagnosing alternative diagnoses (e.g. malignancy and inflammatory bowel disease) that can mimic IAM

  13. The OMERACT psoriatic arthritis magnetic resonance imaging scoring system (PsAMRIS): definitions of key pathologies, suggested MRI sequences, and preliminary scoring system for PsA Hands

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; McQueen, Fiona; Wiell, Charlotte

    2009-01-01

    This article describes a preliminary OMERACT psoriatic arthritis magnetic resonance image scoring system (PsAMRIS) for evaluation of inflammatory and destructive changes in PsA hands, which was developed by the international OMERACT MRI in inflammatory arthritis group. MRI definitions of important...... pathologies in peripheral PsA and suggestions concerning appropriate MRI sequences for use in PsA hands are also provided....

  14. Calibration, characterization, and first results with the Ocean PHILLS hyperspectral imager

    Science.gov (United States)

    Davis, Curtiss O.; Kappus, Mary E.; Bowles, Jeffrey H.; Fisher, John; Antoniades, John A.; Carney, Megan

    1999-10-01

    The Ocean Portable Hyperspectral Imager for Low-Light spectroscopy (Ocean PHILLS), is a new hyperspectral imager specifically designed for imaging the coastal ocean. It uses a thinned, backside illuminated CCD for high sensitivity, and an all-reflective spectrograph with a convex grating in an Offner configuration to produce a distortion free image. Here we describe the instrument design and present the results of laboratory calibration and characterization and example results from a two week field experiment imaging the coastal waters off Lee Stocking, Island, Bahamas.

  15. Discrimination of grassland species and their classification in botanical families by laboratory scale hyperspectral imaging NIR: preliminary results

    Science.gov (United States)

    The objective of this study was to discriminate by on-line hyperspectral imaging, taxonomic plant families comprised of different grassland species. Plants were collected from semi-natural meadows of the National Apuseni Park, Apuseni Mountains, Gârda area (Romania) according to botanical families. ...

  16. 13N-NH3 PET in the diagnosis of astrocytomas: preliminary result

    International Nuclear Information System (INIS)

    Zhang Xiangsong; He Zuoxiang; Tang Anwu

    2004-01-01

    Objective: To evaluate the feasibility of diagnosing the astrocytoma with 13N-NH3 PET imaging. Methods 13N-NH3 and 18F-fluorodeoxyglucose (FDG) PET imaging were performed in seven cases of astrocytomas including 3 anteoperative astrocytomas, 2 recurrent astrocytomas, 2 brain injury or necrosis after the operation and radiotherapy. The radioactivity ratios of the tumor and normal white matter (T/WM) were calculated. Results: The tumor lesions in 3 anteoperative astrocytomas and 2 recurrent astrocytomas all uptake 13N-NH3. The average T/WM on 13N-NH3 images was 1.82±0.21, and T/WM on 13N-NH3 and 18F-FDG images were 1.98 and 0.97 for one case with grade 1 astrocytoma. 13N-NH3 and 18F-FDG PET imaging both showed decreased uptake in 2 brain injury or necrosis after the operation and radiotherapy of astrocytomas. Conclusions: 13N-NH3 was uptaken in astrocytomas. 13N-NH3 can be useful in the diagnosis of astrocytoma, and potentially improve diagnostic accuracy of astrocytoma, especially in low-grade astrocytoma. (authors)

  17. 13N-NH3 PET in the diagnosis of astrocytomas: preliminary result

    International Nuclear Information System (INIS)

    Zhang Xiangsong; He Zuoxiang; Tang Anwu

    2004-01-01

    Objective: To evaluate the feasibility of diagnosing the astrocytoma with 13N-NH3 PET imaging. Methods: 13N-NH3 and 18F-fluorodeoxyglucose (FDG) PET imaging were performed in seven cases of astrocytomas including 3 anteoperative astrocytomas, 2 recurrent astrocytomas, 2 brain injury or necrosis after the operation and radiotherapy. The radioactivity ratios of the tumor and normal white matter (T/WM) were calculated. Results: The tumor lesions in 3 anteoperative astrocytomas and 2 recurrent astrocytomas all uptake 13N-NH3 .The average T/WM on 13N-NH3 images was 1.82±0.21, and T/WM on 13N-NH3 and 18F-FDG images were 1.98 and 0.97 for one case with grade 1 astrocytoma. 13N-NH3 and 18F-FDG PET imaging both showed decreased uptake in 2 brain injury or necrosis after the operation and radiotherapy of astrocytomas. Conclusions: 13N-NH3 was uptaken in astrocytomas. 13N-NH3 can be useful in the diagnosis of astrocytoma, and potentially improve diagnostic accuracy of astrocytoma, especially in low-grade astrocytoma. (authors)

  18. Modelling lung cancer due to radon and smoking in WISMUT miners: Preliminary results

    International Nuclear Information System (INIS)

    Bijwaard, H.; Dekkers, F.; Van Dillen, T.

    2011-01-01

    A mechanistic two-stage carcinogenesis model has been applied to model lung-cancer mortality in the largest uranium-miner cohort available. Models with and without smoking action both fit the data well. As smoking information is largely missing from the cohort data, a method has been devised to project this information from a case-control study onto the cohort. Model calculations using 256 projections show that the method works well. Preliminary results show that if an explicit smoking action is absent in the model, this is compensated by the values of the baseline parameters. This indicates that in earlier studies performed without smoking information, the results obtained for the radiation parameters are still valid. More importantly, the inclusion of smoking-related parameters shows that these mainly influence the later stages of lung-cancer development. (authors)

  19. Characterization of unifocal liver lesions with pulse inversion harmonic imaging after Levovist injection: preliminary results

    International Nuclear Information System (INIS)

    Bertolotto, M.; Dalla Palma, L.; Quaia, E.; Locatelli, M.

    2000-01-01

    The aim of this study was to evaluate capabilities of pulse inversion harmonic imaging (PIHI) in characterization of unifocal liver lesions. We evaluated with PIHI (HDI5000, ATL, Bothell, Wash.) and spiral CT 46 consecutive patients with a single liver lesion identified by fundamental US [7 hepatocellular carcinomas (HCC), 2 cholangiocarcinomas, 7 focal nodular hyperplasias (FNH), 17 hemangiomas and 13 metastases]. The PIHI was performed before and 30 s, 2 and 4 min after bolus administration of Levovist (2.5 g, 300 mg/ml). Scans were digitally stored and reviewed using a dedicated software. Hepatocellular carcinoma was hyperechoic on 30-s scan, and hypoechoic (n = 5) or isoechoic (n = 2) on 2-min scan. Cholangiocarcinoma had inhomogeneous persistent enhancement. Focal nodular hyperplasia was hyperechoic (n = 5) or isoechoic (n = 2) on 30-s scan, hyperechoic (n = 4), isoechoic (n = 2) or slightly hypoechoic (n = 1) on 2-min scan. Large hemangioma revealed peripheral enhancement on 30-s scan which extended centripetally on 2-min scan. Small hemangioma appeared isoechoic on 2-min scan in all but two cases in which they were hypoechoic on 2-min scans and hyperechoic on 4-min scan. Metastasis was hypoechoic on all scans, 70 % with rim enhancement. Similar changes in enhancement pattern have been observed at spiral CT. The 30-s and the 2-min scans revealed a conclusive importance in characterization of HCC, cholangiocarcinoma, and large hemangioma. The 2-min scan often furnished enough information for characterization of small hemangioma and metastasis. The 4-min scan allowed characterization of two hemangiomas which appeared hypoechoic on 2-min scans. In the other cases it did not provide further information. Diagnosis of FNH is usually reached with Colour Doppler US; PIHI should be used when colour Doppler is biased by artefacts or when colour Doppler findings are not characteristic. Our results seem to show that PIHI could be a valuable alternative diagnostic

  20. 3D mutifractal analysis of cerebral tomoscintigraphy images

    International Nuclear Information System (INIS)

    Lopes, R.; Dubois, P.; Dewalle, A.S.; Betrouni, N.; Steinling, M.; Maouche, S.

    2007-01-01

    In this study, we describe the preliminary results of a tool to assist the diagnosis for the characterization of pathological cases of epilepsy disease using cerebral tomoscintigraphy images. The tool is based on the use of multifractal modelling to detect the local changes of homogeneity. (orig.)

  1. Retrospective study of sonographic findings in bone involvement associated with rotator cuff calcific tendinopathy: preliminary results of a case series

    Directory of Open Access Journals (Sweden)

    Marcello H. Nogueira-Barbosa

    2015-12-01

    Full Text Available Abstract Objective: The present study was aimed at investigating bone involvement secondary to rotator cuff calcific tendonitis at ultrasonography. Materials and Methods: Retrospective study of a case series. The authors reviewed shoulder ultrasonography reports of 141 patients diagnosed with rotator cuff calcific tendonitis, collected from the computer-based data records of their institution over a four-year period. Imaging findings were retrospectively and consensually analyzed by two experienced musculoskeletal radiologists looking for bone involvement associated with calcific tendonitis. Only the cases confirmed by computed tomography were considered for descriptive analysis. Results: Sonographic findings of calcific tendinopathy with bone involvement were observed in 7/141 (~ 5% patients (mean age, 50.9 years; age range, 42-58 years; 42% female. Cortical bone erosion adjacent to tendon calcification was the most common finding, observed in 7/7 cases. Signs of intraosseous migration were found in 3/7 cases, and subcortical cysts in 2/7 cases. The findings were confirmed by computed tomography. Calcifications associated with bone abnormalities showed no acoustic shadowing at ultrasonography, favoring the hypothesis of resorption phase of the disease. Conclusion: Preliminary results of the present study suggest that ultrasonography can identify bone abnormalities secondary to rotator cuff calcific tendinopathy, particularly the presence of cortical bone erosion.

  2. 76 FR 41759 - Fresh Garlic From the People's Republic of China: Extension of Time Limit for Preliminary Results...

    Science.gov (United States)

    2011-07-15

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-831] Fresh Garlic From the People's Republic of China: Extension of Time Limit for Preliminary Results of Antidumping Duty... (``Department'') published a notice of initiation of an administrative review of fresh garlic from the People's...

  3. 75 FR 32361 - Fresh Garlic From The People's Republic of China: Extension of Time Limit for Preliminary Results...

    Science.gov (United States)

    2010-06-08

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-831] Fresh Garlic From The People's Republic of China: Extension of Time Limit for Preliminary Results of Antidumping Duty... Commerce (``Department'') published a notice of initiation of an administrative review of fresh garlic from...

  4. 76 FR 65496 - Certain Orange Juice From Brazil; Notice of Extension of Time Limits for Preliminary Results of...

    Science.gov (United States)

    2011-10-21

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-351-840] Certain Orange Juice From Brazil; Notice of Extension of Time Limits for Preliminary Results of Antidumping Duty Administrative... antidumping duty order on certain orange juice from Brazil. See Initiation of Antidumping and Countervailing...

  5. 75 FR 69917 - Certain Orange Juice From Brazil; Notice of Extension of Time Limits for Preliminary Results of...

    Science.gov (United States)

    2010-11-16

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-351-840] Certain Orange Juice From Brazil; Notice of Extension of Time Limits for Preliminary Results of Antidumping Duty Administrative... antidumping duty order on certain orange juice from Brazil. See Initiation of Antidumping and Countervailing...

  6. Synthetic Aperture Imaging in Medical Ultrasound

    DEFF Research Database (Denmark)

    Nikolov, Svetoslav; Gammelmark, Kim; Pedersen, Morten

    2004-01-01

    with high precision, and the imaging is easily extended to real-time 3D scanning. This paper presents the work done at the Center for Fast Ultrasound Imaging in the area of SA imaging. Three areas that benefit from SA imaging are described. Firstly a preliminary in-vivo evaluation comparing conventional B...

  7. Krypton for computed tomography lung ventilation imaging: preliminary animal data.

    Science.gov (United States)

    Mahnken, Andreas H; Jost, Gregor; Pietsch, Hubertus

    2015-05-01

    The objective of this study was to assess the feasibility and safety of krypton ventilation imaging with intraindividual comparison to xenon ventilation computed tomography (CT). In a first step, attenuation of different concentrations of xenon and krypton was analyzed in a phantom setting. Thereafter, 7 male New Zealand white rabbits (4.4-6.0 kg) were included in an animal study. After orotracheal intubation, an unenhanced CT scan was obtained in end-inspiratory breath-hold. Thereafter, xenon- (30%) and krypton-enhanced (70%) ventilation CT was performed in random order. After a 2-minute wash-in of gas A, CT imaging was performed. After a 45-minute wash-out period and another 2-minute wash-in of gas B, another CT scan was performed using the same scan protocol. Heart rate and oxygen saturation were measured. Unenhanced and krypton or xenon data were registered and subtracted using a nonrigid image registration tool. Enhancement was quantified and statistically analyzed. One animal had to be excluded from data analysis owing to problems during intubation. The CT scans in the remaining 6 animals were completed without complications. There were no relevant differences in oxygen saturation or heart rate between the scans. Xenon resulted in a mean increase of enhancement of 35.3 ± 5.5 HU, whereas krypton achieved a mean increase of 21.9 ± 1.8 HU in enhancement (P = 0.0055). The use of krypton for lung ventilation imaging appears to be feasible and safe. Despite the use of a markedly higher concentration of krypton, enhancement is significantly worse when compared with xenon CT ventilation imaging, but sufficiently high for CT ventilation imaging studies.

  8. Effects of dialectical behaviour therapy-mindfulness training on emotional reactivity in borderline personality disorder: preliminary results.

    Science.gov (United States)

    Feliu-Soler, Albert; Pascual, Juan C; Borràs, Xavier; Portella, Maria J; Martín-Blanco, Ana; Armario, Antonio; Alvarez, Enric; Pérez, Víctor; Soler, Joaquim

    2014-01-01

    Emotional dysregulation has been proposed as a hallmark of borderline personality disorder (BPD). Mindfulness techniques taught in dialectical behaviour therapy (DBT) appear to be effective in reducing affective symptoms and may enhance emotion regulation in BPD patients. In the present study, we assessed whether 10 weeks of DBT-mindfulness (DBT-M) training added to general psychiatric management (GPM) could improve emotion regulation in BPD patients. A total of 35 patients with BPD were included and sequentially assigned to GPM (n = 17) or GPM plus DBT-M (n = 18). Participants underwent a negative emotion induction procedure (presentation of standardized unpleasant images) both pre-intervention and post-intervention. Clinical evaluation was also performed before and after treatment. No differences were observed in emotional response at the post-treatment session. However, patients in the DBT-M group showed greater improvement in clinical symptoms. Formal mindfulness practice was positively correlated with clinical improvements and lower self-reported emotional reactivity. Our preliminary results suggest that mindfulness training reduces some psychiatric symptoms but may not have a clear effect on how patients respond to emotional stimuli in an experimental setting. No clear effect of mindfulness training was observed on emotional response to a negative emotion induction procedure. Application of the DBT-M module jointly to GPM induced better clinical outcomes than GPM alone. Formal mindfulness practice showed a positive impact on emotion regulation and clinical improvement. Copyright © 2013 John Wiley & Sons, Ltd.

  9. Preliminary Results of 3D-DDTC Pixel Detectors for the ATLAS Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    La Rosa, Alessandro; /CERN; Boscardin, M.; /Fond. Bruno Kessler, Povo; Dalla Betta, G.-F.; /Trento U. /INFN, Trento; Darbo, G.; Gemme, C.; /INFN, Genoa; Pernegger, H.; /CERN; Piemonte, C.; /Fond. Bruno Kessler, Povo; Povoli, M.; /Trento U. /INFN, Trento; Ronchin, S.; /Fond. Bruno Kessler, Povo; Zoboli, A.; /Trento U. /INFN, Trento; Zorzi, N.; /Fond. Bruno Kessler, Povo; Bolle, E.; /Oslo U.; Borri, M.; /INFN, Turin /Turin U.; Da Via, C.; /Manchester U.; Dong, S.; /SLAC; Fazio, S.; /Calabria U.; Grenier, P.; /SLAC; Grinstein, S.; /Barcelona, IFAE; Gjersdal, H.; /Oslo U.; Hansson, P.; /SLAC; Huegging, F.; /Bonn U. /SLAC /INFN, Turin /Turin U. /Oslo U. /Bergen U. /Oslo U. /Prague, Tech. U. /Bonn U. /SUNY, Stony Brook /Bonn U. /SLAC

    2012-04-04

    3D Silicon sensors fabricated at FBK-irst with the Double-side Double Type Column (DDTC) approach and columnar electrodes only partially etched through p-type substrates were tested in laboratory and in a 1.35 Tesla magnetic field with a 180 GeV pion beam at CERN SPS. The substrate thickness of the sensors is about 200 {mu}m, and different column depths are available, with overlaps between junction columns (etched from the front side) and ohmic columns (etched from the back side) in the range from 110 {mu}m to 150 {mu}m. The devices under test were bump bonded to the ATLAS Pixel readout chip (FEI3) at SELEX SI (Rome, Italy). We report leakage current and noise measurements, results of functional tests with Am{sup 241} {gamma}-ray sources, charge collection tests with Sr90 {beta}-source and an overview of preliminary results from the CERN beam test.

  10. Economic evaluation of short-term wind power forecast in ERCOT. Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Orwig, Kirsten D.; Hodge, Bri-Mathias; Brinkman, Greg; Ela, Erik; Milligan, Michael [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Banunarayanan, Venkat; Nasir, Saleh [ICF International, Fairfax, VA (United States); Freedman, Jeff [AWS Truepower, Albany, NY (United States)

    2012-07-01

    A number of wind energy integration studies have investigated the monetary value of using day-ahead wind power forecasts for grid operation decisions. Historically, these studies have shown that large cost savings could be gained by grid operators implementing the forecasts in their system operations. To date, none of these studies have investigated the value of shorter term (0- to 6-h ahead) wind power forecasts. In 2010, the Department of Energy and the National Oceanic and Atmospheric Administration partnered to form the Wind Forecasting Improvement Project (WFIP) to fund improvements in short-term wind forecasts and determine the economic value of these improvements to grid operators. In this work, we discuss the preliminary results of the economic benefit analysis portion of the WFIP for the Electric Reliability Council of Texas. The improvements seen in the wind forecasts are examined and the economic results of a production cost model simulation are analyzed. (orig.)

  11. Preliminary genetic imaging study of the association between estrogen receptor-α gene polymorphisms and harsh human maternal parenting.

    Science.gov (United States)

    Lahey, Benjamin B; Michalska, Kalina J; Liu, Chunyu; Chen, Qi; Hipwell, Alison E; Chronis-Tuscano, Andrea; Waldman, Irwin D; Decety, Jean

    2012-09-06

    A failure of neural changes initiated by the estrogen surge in late pregnancy to reverse the valence of infant stimuli from aversive to rewarding is associated with dysfunctional maternal behavior in nonhuman mammals. Estrogen receptor-α plays the crucial role in mediating these neural effects of estrogen priming. This preliminary study examines associations between estrogen receptor-α gene polymorphisms and human maternal behavior. Two polymorphisms were associated with human negative maternal parenting. Furthermore, hemodynamic responses in functional magnetic resonance imaging to child stimuli in neural regions associated with social cognition fully mediated the association between genetic variation and negative parenting. This suggests testable hypotheses regarding a biological pathway between genetic variants and dysfunctional human maternal parenting. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  12. Diffusion-weighted breast imaging at 3 T: Preliminary experience

    International Nuclear Information System (INIS)

    Nogueira, L.; Brandão, S.; Matos, E.; Nunes, R.G.; Ferreira, H.A.; Loureiro, J.; Ramos, I.

    2014-01-01

    Aim: To evaluate the performance of diffusion-weighted imaging (DWI) at 3 T for the detection and characterization of breast lesions. Materials and methods: Magnetic resonance imaging (MRI) of the breast, including DWI single-shot spin-echo echo planar images (SS-SE-EPI; eight b-values, 50–3000 s/mm 2 ), were acquired in women with a clinical indication for breast MRI. The exclusion criteria were as follows: (1) previous breast surgery, radiotherapy and/or chemotherapy within the prior 48 months (14 women); (2) only cystic lesions (one woman); (3) no detectable enhancing lesion at dynamic contrast-enhanced (DCE)-MRI (15 women); and (4) breast implants (four women). MRI results were corroborated by histopathology or imaging follow-up. Apparent diffusion coefficients (ADCs) were estimated for lesions and normal glandular tissue. Differences in the ADC between tissue types were evaluated and the sensitivity and specificity of the method calculated by receiver operating characteristics (ROC) curves. Results: The final cohort comprised 53 patients with 59 lesions. Histopathology was obtained for 58 lesions. One lesion was validated as benign on imaging follow-up. Mean ADCs of 1.99 ± 0.27 × 10 −3  mm 2 /s, 1.08 ± 0.25 × 10 −3  mm 2 /s, and 1.74 ± 0.35 × 10 −3  mm 2 /s were obtained for normal tissue, malignant, and benign lesions, respectively. Mean ADCs of malignancies were significantly lower than those of benign lesions (p < 0.001) and normal tissue (p < 0.0001). The sensitivity and specificity for stratifying lesions, considering an ADC threshold of 1.41 × 10 −3  mm 2 /s, were 94.3% and 87.5%, respectively; accuracy was 91.5%. Conclusion: DWI proved useful for the detection and characterization of breast lesions in the present sample. ADC values provide a high diagnostic performance for differentiation between benign and malignant lesions

  13. Radon and radon daughters' concentration in spring and wells waters from Presidente Prudente: preliminary results

    International Nuclear Information System (INIS)

    Osorio, Ana Maria Araya; Saenz, Carlos Alberto Tello; Pereira, Luiz Augusto Stuani

    2009-01-01

    This work presents the preliminary results about the concentration of radon and radon daughters in wells and springs water from Presidente Prudente. Six water samples were studied: three from well-water, two from springs water and one from potable water. For the determination of α-activity the samples were placed inside plastic containers where the CR-39 tracks detectors were outside the water. The track density of α-particles were measured by using optical microscopy. The results show that one sample from well-water presented higher concentration of radon and radon daughters than the other samples. (author)

  14. A new gas stripper system for BARC-TIFR Pelletron Accelerator facility: installation and preliminary results

    International Nuclear Information System (INIS)

    Sharma, S.C.; Ninawe, N.G.; Yadav, M.L.; Ekambaram, M.; Ramjilal; Matkar, U.V.; Ansari, Q.N.; Lokare, R.N.; Ramlal; Gupta, A.K.; Bhagwat, P.V.; Pillay, R.G.

    2009-01-01

    The gas-stripper plays a key role in stripping the heavy and molecular ion beams in a tandem accelerator. Efficiency of gas stripper depends on its supporting vacuum pumps. A new recirculating turbo molecular pump-based gas stripper has been installed in the high voltage terminal of Pelletron Accelerator. Re-circulating the stripper gas reduces the flow of gas into the accelerating tubes reducing the transmission losses. Preliminary results obtained using the new gas stripper system are discussed. (author)

  15. Stock Market Reaction to CEO Appointment – Preliminary Results

    Directory of Open Access Journals (Sweden)

    Katarzyna Byrka-Kita

    2017-06-01

    Full Text Available Purpose: The aim of this paper is to examine shareholders’ reaction to the decision of the supervisory board to appoint a CEO in companies listed on the Warsaw Stock Exchange. Methodology: An event study and the mean-adjusted model were applied. The abnormal returns were measured as the CAAR in the entire (-60, + 60 window and selected sub-windows. Findings: The obtained values of abnormal returns indicate the shareholder’s negative reaction. Throughout the observation window, they oscillate slightly below zero, and in the window (0, +20 they are negative at -1.566%. Irrespective of the observation window, negative abnormal returns were obtained for over half of the observation (52–57%. Therefore, preliminary results indicate the predominance of the information effect over the real one. The decrease in market value as a result of the event may result from an increase in investors’ uncertainty as to the effects of changes in strategy and skills of the new CEO. Originality: The research is a unique one. To date, no one has carried out research into shareholders’ reaction to a CEO appointment in either the Polish or Central and Eastern European capital markets. They primarily bring the value of cognition of shareholders’ behaviour in the analysed event, which is reflected in share prices. They extend the literature on the signalization instruments, i.e. the activities that boards can undertake due to the new information transmitted to the capital market participants and stakeholders. The market reaction to a CEO appointment will without a doubt interest investors; the institutions responsible for supervision (which in the case of Poland is the Financial Oversight Commission and the legislator in charge of regulations that prevent insider trading while promoting corporate disclosure transparency.

  16. Correlated diffusion imaging

    International Nuclear Information System (INIS)

    Wong, Alexander; Glaister, Jeffrey; Cameron, Andrew; Haider, Masoom

    2013-01-01

    Prostate cancer is one of the leading causes of cancer death in the male population. Fortunately, the prognosis is excellent if detected at an early stage. Hence, the detection and localization of prostate cancer is crucial for diagnosis, as well as treatment via targeted focal therapy. New imaging techniques can potentially be invaluable tools for improving prostate cancer detection and localization. In this study, we introduce a new form of diffusion magnetic resonance imaging called correlated diffusion imaging, where the tissue being imaged is characterized by the joint correlation of diffusion signal attenuation across multiple gradient pulse strengths and timings. By taking into account signal attenuation at different water diffusion motion sensitivities, correlated diffusion imaging can provide improved delineation between cancerous tissue and healthy tissue when compared to existing diffusion imaging modalities. Quantitative evaluation using receiver operating characteristic (ROC) curve analysis, tissue class separability analysis, and visual assessment by an expert radiologist were performed to study correlated diffusion imaging for the task of prostate cancer diagnosis. These results are compared with that obtained using T2-weighted imaging and standard diffusion imaging (via the apparent diffusion coefficient (ADC)). Experimental results suggest that correlated diffusion imaging provide improved delineation between healthy and cancerous tissue and may have potential as a diagnostic tool for cancer detection and localization in the prostate gland. A new form of diffusion magnetic resonance imaging called correlated diffusion imaging (CDI) was developed for the purpose of aiding radiologists in cancer detection and localization in the prostate gland. Preliminary results show CDI shows considerable promise as a diagnostic aid for radiologists in the detection and localization of prostate cancer

  17. 75 FR 65449 - Stainless Steel Bar From India: Extension of Time Limit for the Preliminary Results of the...

    Science.gov (United States)

    2010-10-25

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-533-810] Stainless Steel Bar From India: Extension of Time Limit for the Preliminary Results of the Antidumping Duty Administrative Review... initiation of an administrative review of the antidumping duty order on stainless steel bar from India...

  18. 77 FR 12008 - Certain Pasta From Italy: Extension of Time Limit for the Preliminary Results of Antidumping Duty...

    Science.gov (United States)

    2012-02-28

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-475-818] Certain Pasta From Italy: Extension of Time Limit for the Preliminary Results of Antidumping Duty Administrative Review AGENCY: Import... notice of initiation of the administrative review of the antidumping duty order on certain pasta from...

  19. Optimization of a Biometric System Based on Acoustic Images

    Directory of Open Access Journals (Sweden)

    Alberto Izquierdo Fuente

    2014-01-01

    Full Text Available On the basis of an acoustic biometric system that captures 16 acoustic images of a person for 4 frequencies and 4 positions, a study was carried out to improve the performance of the system. On a first stage, an analysis to determine which images provide more information to the system was carried out showing that a set of 12 images allows the system to obtain results that are equivalent to using all of the 16 images. Finally, optimization techniques were used to obtain the set of weights associated with each acoustic image that maximizes the performance of the biometric system. These results improve significantly the performance of the preliminary system, while reducing the time of acquisition and computational burden, since the number of acoustic images was reduced.

  20. Optimization of a Biometric System Based on Acoustic Images

    Science.gov (United States)

    Izquierdo Fuente, Alberto; Del Val Puente, Lara; Villacorta Calvo, Juan J.; Raboso Mateos, Mariano

    2014-01-01

    On the basis of an acoustic biometric system that captures 16 acoustic images of a person for 4 frequencies and 4 positions, a study was carried out to improve the performance of the system. On a first stage, an analysis to determine which images provide more information to the system was carried out showing that a set of 12 images allows the system to obtain results that are equivalent to using all of the 16 images. Finally, optimization techniques were used to obtain the set of weights associated with each acoustic image that maximizes the performance of the biometric system. These results improve significantly the performance of the preliminary system, while reducing the time of acquisition and computational burden, since the number of acoustic images was reduced. PMID:24616643

  1. ADREA-I: A transient three dimensional transport code for atmospheric and other applications - some preliminary results

    International Nuclear Information System (INIS)

    Bartzis, G.

    1985-02-01

    In this work a general description of the ADREA-I code is presented and some preliminary results are discussed. The ADREA-I is a transient three dimensional computer code aimed at transport analysis with particular emphasis on atmospheric dispersion under any realistic terrain conditions (complex or not) applicable to the planetary boundary layer in a distance extending up to a hundred kilometers or more. The complex geometry applications and the reasonable results obtained constitute a solid indication of the broad capability of the code. (author)

  2. Detecting early stage pressure ulcer on dark skin using multispectral imager

    Science.gov (United States)

    Yi, Dingrong; Kong, Linghua; Sprigle, Stephen; Wang, Fengtao; Wang, Chao; Liu, Fuhan; Adibi, Ali; Tummala, Rao

    2010-02-01

    We are developing a handheld multispectral imaging device to non-invasively inspect stage I pressure ulcers in dark pigmented skins without the need of touching the patient's skin. This paper reports some preliminary test results of using a proof-of-concept prototype. It also talks about the innovation's impact to traditional multispectral imaging technologies and the fields that will potentially benefit from it.

  3. Image compression software for the SOHO LASCO and EIT experiments

    Science.gov (United States)

    Grunes, Mitchell R.; Howard, Russell A.; Hoppel, Karl; Mango, Stephen A.; Wang, Dennis

    1994-01-01

    This paper describes the lossless and lossy image compression algorithms to be used on board the Solar Heliospheric Observatory (SOHO) in conjunction with the Large Angle Spectrometric Coronograph and Extreme Ultraviolet Imaging Telescope experiments. It also shows preliminary results obtained using similar prior imagery and discusses the lossy compression artifacts which will result. This paper is in part intended for the use of SOHO investigators who need to understand the results of SOHO compression in order to better allocate the transmission bits which they have been allocated.

  4. Spatial and temporal variation of radiocarbon in tree rings - some preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Higham, T.F.G.; Hogg, A.G. [Waikato Univ., Hamilton (New Zealand); McCormac, F.G.; Baillie, M.G.L.; Brown, D. [Queens`s University, Belfast, (Ireland). School of Geosciences; Palmer, J.G.; Xiong, L. [Lincoln University, Canterbury (New Zealand). Department of Plant Science

    1997-12-31

    A number of researchers have identified a measurable difference between the {sup 14}C activities of tree rings of identical dendochronological age between the Northern and the Southern Hemispheres. It is also acknowledged that there is an urgent need for new high precision {Delta}{sup 14}C data from tree rings in both Hemispheres to help resolve the questions relating to the magnitude and cause of the locality and temporal dependence of the {Delta}{sup 14}C record, to provide a reliable Southern Hemisphere calibration curve and to throw light upon the 1986 and 1993 Calibration data set discrepancies. In this paper, the authors present the research design of a project to investigate these critical issues in radiocarbon age calibration and describe the preliminary results. Paper no. 30; Extended abstract; 12 refs.

  5. ACTPol: Status and preliminary CMB polarization results from the Atacama Cosmology Telescope

    Science.gov (United States)

    Koopman, Brian

    2014-03-01

    The Atacama Cosmology Telescope Polarimeter (ACTPol) is a polarization sensitive upgrade for the Atacama Cosmology Telescope, located at an elevation of 5190 m on Cerro Toco in Chile. In summer 2013, ACTPol achieved first light with one third of the final detector configuration. The remaining two thirds of the detector array will be installed during spring 2014, enabling full sensitivity, high resolution, observations at both 90 GHz and 150 GHz. Using approximately 3,000 transition-edge sensor bolometers, ACTPol will enable measurements of small angular scale polarization anisotropies in the Cosmic Microwave Background (CMB). I will present a status update for the ACTPol receiver and some preliminary results. ACTPol measurements will allow us to probe the spectral index of inflation as well as to constrain early dark energy and the sum of neutrino masses.

  6. Preliminary results of hydrologic testing of the Umtanum Basalt Fracture Zone at borehole RRL-2 (3,781 to 3,827 ft)

    International Nuclear Information System (INIS)

    Strait, S.R.; Spane, F.A. Jr.

    1983-02-01

    This report presents preliminary results and description of hydrologic test activities for the Umtanum Basalt Fracture Zone at Borehole RRL-2, within the test interval 3,781 to 3,827 feet. Hydrologic tests conducted include two short-term, constant discharge pumping tests and two slug tests. Preliminary results indicate an observed hydraulic head for the test interval of 406.7 feet above mean sea level. Transmissivity values determined from hydrologic tests performed range between 205 and 881 ft 2 /day. The best estimate of equivalent hydraulic conductivity, based on an effective test thickness of 6 feet, is 147 ft/day. 8 refs., 6 figs., 3 tabs

  7. Plans and Preliminary Results of Fundamental Studies of Ice Crystal Icing Physics in the NASA Propulsion Systems Laboratory

    Science.gov (United States)

    Struk, Peter; Tsao, Jen-Ching; Bartkus, Tadas

    2017-01-01

    This paper describes plans and preliminary results for using the NASA Propulsion Systems Lab (PSL) to experimentally study the fundamental physics of ice-crystal ice accretion. NASA is evaluating whether this facility, in addition to full-engine and motor-driven-rig tests, can be used for more fundamental ice-accretion studies that simulate the different mixed-phase icing conditions along the core flow passage of a turbo-fan engine compressor. The data from such fundamental accretion tests will be used to help develop and validate models of the accretion process. This paper presents data from some preliminary testing performed in May 2015 which examined how a mixed-phase cloud could be generated at PSL using evaporative cooling in a warmer-than-freezing environment.

  8. Biomarkers of Eating Disorders Using Support Vector Machine Analysis of Structural Neuroimaging Data: Preliminary Results

    Directory of Open Access Journals (Sweden)

    Antonio Cerasa

    2015-01-01

    Full Text Available Presently, there are no valid biomarkers to identify individuals with eating disorders (ED. The aim of this work was to assess the feasibility of a machine learning method for extracting reliable neuroimaging features allowing individual categorization of patients with ED. Support Vector Machine (SVM technique, combined with a pattern recognition method, was employed utilizing structural magnetic resonance images. Seventeen females with ED (six with diagnosis of anorexia nervosa and 11 with bulimia nervosa were compared against 17 body mass index-matched healthy controls (HC. Machine learning allowed individual diagnosis of ED versus HC with an Accuracy ≥ 0.80. Voxel-based pattern recognition analysis demonstrated that voxels influencing the classification Accuracy involved the occipital cortex, the posterior cerebellar lobule, precuneus, sensorimotor/premotor cortices, and the medial prefrontal cortex, all critical regions known to be strongly involved in the pathophysiological mechanisms of ED. Although these findings should be considered preliminary given the small size investigated, SVM analysis highlights the role of well-known brain regions as possible biomarkers to distinguish ED from HC at an individual level, thus encouraging the translational implementation of this new multivariate approach in the clinical practice.

  9. Biomarkers of Eating Disorders Using Support Vector Machine Analysis of Structural Neuroimaging Data: Preliminary Results

    Science.gov (United States)

    Cerasa, Antonio; Castiglioni, Isabella; Salvatore, Christian; Funaro, Angela; Martino, Iolanda; Alfano, Stefania; Donzuso, Giulia; Perrotta, Paolo; Gioia, Maria Cecilia; Gilardi, Maria Carla; Quattrone, Aldo

    2015-01-01

    Presently, there are no valid biomarkers to identify individuals with eating disorders (ED). The aim of this work was to assess the feasibility of a machine learning method for extracting reliable neuroimaging features allowing individual categorization of patients with ED. Support Vector Machine (SVM) technique, combined with a pattern recognition method, was employed utilizing structural magnetic resonance images. Seventeen females with ED (six with diagnosis of anorexia nervosa and 11 with bulimia nervosa) were compared against 17 body mass index-matched healthy controls (HC). Machine learning allowed individual diagnosis of ED versus HC with an Accuracy ≥ 0.80. Voxel-based pattern recognition analysis demonstrated that voxels influencing the classification Accuracy involved the occipital cortex, the posterior cerebellar lobule, precuneus, sensorimotor/premotor cortices, and the medial prefrontal cortex, all critical regions known to be strongly involved in the pathophysiological mechanisms of ED. Although these findings should be considered preliminary given the small size investigated, SVM analysis highlights the role of well-known brain regions as possible biomarkers to distinguish ED from HC at an individual level, thus encouraging the translational implementation of this new multivariate approach in the clinical practice. PMID:26648660

  10. Preliminary results from receiver function analysis in a seismological network across the Pamir

    Science.gov (United States)

    Schneider, Felix M.; Yuan, Xiaohui; Sippl, Christan; Schurr, Bernd; Mechie, James; Minaev, Vlad; Oimahmadov, Ilhomjon; Gadoev, Mustafo; Abdybachaev, Ulan A.

    2010-05-01

    The multi-disciplinary TIen Shan-PAmir GEodynamic (TIPAGE) program aims to investigate the dynamics of the orogeny of the Tien Shan and Pamir mountains, which are situated in south Kyrgyzstan and east Tajikistan in Central Asia. Deformation and uplift accompanied by crustal thickening is mainly induced by the collision between the Indian and Eurasian continental plates. As a local feature this collision provides the world's largest active intra-continental subduction zone. Within the framework of the TIPAGE program we operate a temporary seismic array consisting of 32 broadband and 8 short period seismic stations for a period of two years (from 2008 to 2010) covering an area of 300 x 300 km over the main part of the central Pamir plateau and the Alai-range of the southern Tien Shan. In the first year 24 broadband stations were set up in a 350-km long north-south profile geometry from Osh in southern Kyrgyzstan to Zorkul in south-eastern Tajikistan with approximately 15 km station spacing. We perform a receiver function (RF) analysis of converted P and S waves from teleseismic earthquakes at epicentral distances of 35-95 degrees with a minimum magnitude of 5.5. Therefore we decompose their wavefields by rotating the coordinate systems of the recorded seismograms from a N,E,Z into a SH,SV,P system. RFs are isolated by deconvolution of the P-component from the SH- and SV-component. They provide a robust tool to locate discontinuities in wave velocity like the Moho and thus represent the method of choice to determine crustal thickness. First results show a crustal thickness of 70-80km. Xenolith findings from depths of 100km reported by Hacker et al. (2005) give indication for even higher values. The N-S profile geometry will produce a high resolution RF image to map the gross crustal and lithospheric structure. In addition a 2D network with additional 16 stations will enable an investigation of lateral structure variation. We give an introduction to the project and

  11. Terahertz pulse imaging for tree-ring analysis: a preliminary study for dendrochronology applications

    International Nuclear Information System (INIS)

    Jackson, J B; Mourou, M; Whitaker, J F; Labaune, J; Mourou, G A; Duling, I N III; Williamson, S L; Lavier, C; Menu, M

    2009-01-01

    Time-domain terahertz reflection imaging is presented as a novel method of measuring otherwise inaccessible tree rings in wooden cultural heritage for the purpose of tree-ring crossdating. Axial and lateral two-dimensional terahertz images of obscured ring patterns are statistically validated with respect to their corresponding optical photographs via adapted dendrochronological methods. Results are compared to similar analysis of x-ray images of a wood specimen

  12. High bit depth infrared image compression via low bit depth codecs

    DEFF Research Database (Denmark)

    Belyaev, Evgeny; Mantel, Claire; Forchhammer, Søren

    2017-01-01

    images via 8 bit depth codecs in the following way. First, an input 16 bit depth image is mapped into 8 bit depth images, e.g., the first image contains only the most significant bytes (MSB image) and the second one contains only the least significant bytes (LSB image). Then each image is compressed.......264/AVC codecs, which are usually available in efficient implementations, and compare their rate-distortion performance with JPEG2000, JPEG-XT and H.265/HEVC codecs supporting direct compression of infrared images in 16 bit depth format. A preliminary result shows that two 8 bit H.264/AVC codecs can...

  13. Comparison of measurement results between cervical pedicle specimens and CT images

    International Nuclear Information System (INIS)

    Zhang Guangjian; Li Hua; Liu Haiyan; Gao Zhenping

    2011-01-01

    Objective: To compare the difference between the measurement results of the cervical pedicle specimens and CT image, and provide the basis for clinical cervical screw internal fixation operation. Methods: Twenty-seven Chinese adult cadaver cervical specimens including C3 to C7 vertebrae were measured by a digital calipers and CT image, containing pedicle height (PH, PH'), pedicle width(PW, PW'), total pedicle length (TL, TL') and two pedicle lengths(PL1, PL2; PL1', PL2'). The results of specimens and CT image were compared. Results: Different cervical vertebra in the same side of specimens or CT images, PW (PW'): C3, C4< C5, C6 (P<0.05), C5, C6< C7 (P<0.01); PH (PH'): there were no significant differences; TL, PL1, PL2 (TL', PL1', PL2'): there were no marked differences. In the same cervical vertebra of the specimens or CT images, PW (PW')< PH (PH') (P<0.01), PL1 (PL1') < PL2 (PL2') (P<0.01). Conclusion: The results of measurement by CT images are not markedly different from that of specimens. CT image measurement is available before cervical screw internal fixation operation. (authors)

  14. Electromagnetic-Tracked Biopsy under Ultrasound Guidance: Preliminary Results

    International Nuclear Information System (INIS)

    Hakime, Antoine; Deschamps, Frederic; Marques De Carvalho, Enio Garcia; Barah, Ali; Auperin, Anne; Baere, Thierry De

    2012-01-01

    Purpose: This study was designed to evaluate the accuracy and safety of electromagnetic needle tracking for sonographically guided percutaneous liver biopsies. Methods: We performed 23 consecutive ultrasound-guided liver biopsies for liver nodules with an electromagnetic tracking of the needle. A sensor placed at the tip of a sterile stylet (18G) inserted in a coaxial guiding trocar (16G) used for biopsy was localized in real time relative to the ultrasound imaging plane, thanks to an electromagnetic transmitter and two sensors on the ultrasound probe. This allows for electronic display of the needle tip location and the future needle path overlaid on the real-time ultrasound image. Distance between needle tip position and its electronic display, number of needle punctures, number of needle pull backs for redirection, technical success (needle positioned in the target), diagnostic success (correct histopathology result), procedure time, and complication were evaluated according to lesion sizes, depth and location, operator experience, and “in-plane” or “out-of-plane” needle approach. Results: Electronic display was always within 2 mm from the real position of the needle tip. The technical success rate was 100%. A single needle puncture without repuncture was used in all patients. Pull backs were necessary in six patients (26%) to obtain correct needle placement. The overall diagnostic success rate was 91%. The overall true-positive, true-negative, false-negative, and failure rates of the biopsy were 100% (19/19) 100% (2/2), 0% (0/23), and 9% (2/23). The median total procedure time from the skin puncture to the needle in the target was 30 sec (from 5–60 s). Lesion depth and localizations, operator experience, in-plane or out-of-plane approach did not affect significantly the technical, diagnostic success, or procedure time. Even when the tumor size decreased, the procedure time did not increase. Conclusions: Electromagnetic-tracked biopsy is accurate to

  15. Transsphenoidal pituitary resection with intraoperative MR guidance: preliminary results

    Science.gov (United States)

    Pergolizzi, Richard S., Jr.; Schwartz, Richard B.; Hsu, Liangge; Wong, Terence Z.; Black, Peter M.; Martin, Claudia; Jolesz, Ferenc A.

    1999-05-01

    The use of intraoperative MR image guidance has the potential to improve the precision, extent and safety of transsphenoidal pituitary resections. At Brigham and Women's Hospital, an open-bore configuration 0.5T MR system (SIGNA SP, GE Medical Systems, Milwaukee, WI) has been used to provide image guidance for nine transsphenoidal pituitary adenoma resections. The intraoperative MR system allowed the radiologist to direct the surgeon toward the sella turcica successfully while avoiding the cavernous sinus, optic chiasm and other sensitive structures. Imaging performed during the surgery monitored the extent of resection and allowed for removal of tumor beyond the surgeon's view in five cases. Dynamic MR imaging was used to distinguish residual tumor from normal gland and postoperative changes permitting more precise tumor localization. A heme-sensitive long TE gradient echo sequence was used to evaluate for the presence of hemorrhagic debris. All patients tolerated the procedure well without significant complications.

  16. Spectral Monitoring of AGN: Preliminary Results for Ark 564 and Arp 102B

    Directory of Open Access Journals (Sweden)

    Shapovalova A. I.

    2011-09-01

    Full Text Available We present preliminary results of the long-term spectral monitoring of two active galactic nuclei with different broad line shapes: Ark 564 and Arp 102B. Ark 564 is a bright nearby narrow-line Syfert 1 (NLS1 galaxy with relatively narrow permitted optical emission lines and a high Fe II/Hβ ratio, while Arp 102B is a nearby broad-line radio galaxy with broad double-peaked Balmer emission lines. The spectra of Ark 564 were observed during 11-year period (1999-2009 and the spectra of Arp 102B in the 12-year period (1998-2009, with SAO 6 m and 1 m telescopes (Russia and the OAGH 2.1 m telescope (Cananea, Mexico.

  17. Preliminary Results from Integrating Compton Photon Polarimetry in Hall A of Jefferson Lab

    International Nuclear Information System (INIS)

    Parno, D; Friend, M; Benmokhtar, F; Franklin, G; Quinn, B; Michaels, R; Nanda, S; Souder, P

    2011-01-01

    A wide range of nucleon and nuclear structure experiments in Jefferson Lab's Hall A require precise, continuous measurements of the polarization of the electron beam. In our Compton polarimeter, electrons are scattered off photons in a Fabry-Perot cavity; by measuring an asymmetry in the integrated signal of the scattered photons detected in a GSO crystal, we can make non-invasive, continuous measurements of the beam polarization. Our goal is to achieve 1% statistical error within two hours of running. We discuss the design and commissioning of an upgrade to this apparatus, and report preliminary results for experiments conducted at beam energies from 3.5 to 5.9 GeV and photon rates from 5 to 100 kHz.

  18. Digital cardiovascular imaging

    International Nuclear Information System (INIS)

    Myerowitz, P.D.; Mistretta, C.A.; Shaw, C.-G.; Van Lysel, M.S.; Swanson, D.K.; Lasser, T.A.; Dhanani, S.P.; Zarnstorff, W.C.; Vander Ark, C.R.; Dobbins, J.T.; Peppler, W.W.; Crummy, A.B.

    1982-01-01

    The authors have previously reported on real time digital fluoroscopic subtraction techniques developed in the laboratory during the past 10 years. This paper outlines basic apparatus configuration and imaging modes used for preliminary studies involving visualization of the canine and human heart. All of the techniques involve the use of real time digital subtraction processing of data from an image intensified television fluoroscopy system. Based on the configuration of the digital processing equipment a number of different imaging modalities are possible. A brief description of the apparatus and these imaging modes is given. (Auth.)

  19. Life span studies on mice exposed to heavy charged particles or photons: preliminary results

    International Nuclear Information System (INIS)

    Ainsworth, E.J.

    1980-01-01

    This chapter summarizes the results currently available where dose-dependent mortality is compared among the single cohort that received fractionated doses of carbon ions and the first replicate that received single doses. At this time, 17% mortality has occurred in both groups and had enhanced life shortening been produced by fractionation of the carbon ion dose, somewhat higher mortality might be expected. Cautious interpretation of these preliminary results is necessary, but the mortality data available at this time provides no evidence for enhancement by dose fractionation with carbon ions. In sum, at this time, it appears the Q factor used for fission spectrum neutrons could be conservative if it were used for assessment of risk following exposure to 400 MeV carbon ions

  20. Diagnostic difficulties resulting from morphological image variation in spondylodiscitis MR imaging

    International Nuclear Information System (INIS)

    Dziurzyńska-Białek, Ewa; Kruk-Bachonko, Joanna; Guz, Wiesław; Łosicki, Marek; Krupski, Witold

    2012-01-01

    Spinal infection (discitis; spondylodiscitis) presents a wide spectrum of pathologies. The method of choice for spondylodiscitis imaging is magnetic resonance (MR). It provides detailed anatomical information, especially concerning epidural space and spinal cord. The main aim of this article is the description and evaluation of spondylodiscitis morphological variation visible in magnetic resonance imaging. In this article we retrospectively analysed the patients diagnosed at the Department of Radiology of the Provincial Hospital No 2 in Rzeszów between October 2009 and October 2011. The subjects involved a group of five women aged 41–74 (mean 56.3 years) and eight men aged 46–69 (mean 61,3 years). All patients had spondylodiscitis symptoms. All patients underwent MRI examination before and after the contrast enhancement. In three patients additional CT examination was performed. Following the MRI procedure all patients were diagnosed with typical symptoms of spondylodiscitis. It also revealed a number of pathologies resulting from morphological spondylodiscitis variation. Other pathologies found on the MR images of the study group patients involved epidural intra-canal spinal pathological masses causing spinal cord compression, lung abscess, pyothorax, paravertebral abscesses and epidural empyemas, abscess between adjacent vertebral bodies, abscesses beneath anterior longitudinal ligament, and iliopsoas muscle abscesses. In all cases a destruction of vertebral bodies with end plates loss restriction and cortical layer discontinuity was observed. Moreover, one person was diagnosed with pathological vertebral body fractures and liquefactive necrosis of the vertebral body. Spondylodiscitis manifests itself in a great number of morphological variations visible on the radiological images. Apart from ordinary features of vertebral bodies and discs, progressive spinal destruction is observed together with reactive bone changes and soft tissue infiltration. The latter

  1. Preliminary study of synthetic aperture tissue harmonic imaging on in-vivo data

    Science.gov (United States)

    Rasmussen, Joachim H.; Hemmsen, Martin C.; Madsen, Signe S.; Hansen, Peter M.; Nielsen, Michael B.; Jensen, Jørgen A.

    2013-03-01

    A method for synthetic aperture tissue harmonic imaging is investigated. It combines synthetic aperture sequen- tial beamforming (SASB) with tissue harmonic imaging (THI) to produce an increased and more uniform spatial resolution and improved side lobe reduction compared to conventional B-mode imaging. Synthetic aperture sequential beamforming tissue harmonic imaging (SASB-THI) was implemented on a commercially available BK 2202 Pro Focus UltraView ultrasound system and compared to dynamic receive focused tissue harmonic imag- ing (DRF-THI) in clinical scans. The scan sequence that was implemented on the UltraView system acquires both SASB-THI and DRF-THI simultaneously. Twenty-four simultaneously acquired video sequences of in-vivo abdominal SASB-THI and DRF-THI scans on 3 volunteers of 4 different sections of liver and kidney tissues were created. Videos of the in-vivo scans were presented in double blinded studies to two radiologists for image quality performance scoring. Limitations to the systems transmit stage prevented user defined transmit apodization to be applied. Field II simulations showed that side lobes in SASB could be improved by using Hanning transmit apodization. Results from the image quality study show, that in the current configuration on the UltraView system, where no transmit apodization was applied, SASB-THI and DRF-THI produced equally good images. It is expected that given the use of transmit apodization, SASB-THI could be further improved.

  2. Properties of ABNT 41xx and 86xx cast steel modified with niobium; evaluation methodology and experimental preliminary results

    International Nuclear Information System (INIS)

    Suzczynski, E.F.; Chatterjee, S.; Mueller, Arno

    1982-01-01

    The experimental methodology to evaluate the mechanical properties of ABNT 41xx and 86xx steels modified with NB in the as cast and heat treated conditions and the first preliminary results obtained in a laboratory scale, are presented. (Author) [pt

  3. Preliminary Study on Earthquake Surface Rupture Extraction from Uav Images

    Science.gov (United States)

    Yuan, X.; Wang, X.; Ding, X.; Wu, X.; Dou, A.; Wang, S.

    2018-04-01

    Because of the advantages of low-cost, lightweight and photography under the cloud, UAVs have been widely used in the field of seismic geomorphology research in recent years. Earthquake surface rupture is a typical seismic tectonic geomorphology that reflects the dynamic and kinematic characteristics of crustal movement. The quick identification of earthquake surface rupture is of great significance for understanding the mechanism of earthquake occurrence, disasters distribution and scale. Using integrated differential UAV platform, series images were acquired with accuracy POS around the former urban area (Qushan town) of Beichuan County as the area stricken seriously by the 2008 Wenchuan Ms8.0 earthquake. Based on the multi-view 3D reconstruction technique, the high resolution DSM and DOM are obtained from differential UAV images. Through the shade-relief map and aspect map derived from DSM, the earthquake surface rupture is extracted and analyzed. The results show that the surface rupture can still be identified by using the UAV images although the time of earthquake elapse is longer, whose middle segment is characterized by vertical movement caused by compression deformation from fault planes.

  4. MAAP4 CANDU analysis of a generic CANDU-6 plant: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Petoukhov, S.M.; Mathew, P.M

    2001-10-01

    To support the generic probabilistic safety analysis (PSA) program at AECL, in particular to conduct Level 2 PSA analysis of a CANDU 6 plant undergoing a postulated severe accident, the capability to conduct severe accident consequence analysis for a CANDU plant is required. For this purpose, AECL selected MAAP4 CANDU from a number of other severe accident codes. The necessary models for a generic CANDU 6 station have been implemented in the code, and the code version 0.2 beta was tested using station data, which were assembled for a generic CANDU 6 station. This paper describes the preliminary results of the consequence analysis using MAAP4 CANDU for a generic CANDU 6 station, when it undergoes a station blackout and a large loss-of-coolant accident scenario. The analysis results show that the plant response is consistent with the physical phenomena modeled and the failure criteria used. The results also confirm that the CANDU design is robust with respect to severe accidents, which is reflected in the calculated long times that are available for administering accident management measures to arrest the accident progression before the calandria vessel or containment become at risk. (author)

  5. Preliminary evaluation of cryogenic two-phase flow imaging using electrical capacitance tomography

    Science.gov (United States)

    Xie, Huangjun; Yu, Liu; Zhou, Rui; Qiu, Limin; Zhang, Xiaobin

    2017-09-01

    The potential application of the 2-D eight-electrode electrical capacitance tomography (ECT) to the inversion imaging of the liquid nitrogen-vaporous nitrogen (LN2-VN2) flow in the tube is theoretically evaluated. The phase distribution of the computational domain is obtained using the simultaneous iterative reconstruction technique with variable iterative step size. The detailed mathematical derivations for the calculations are presented. The calculated phase distribution for the two detached LN2 column case shows the comparable results with the water-air case, regardless of the much reduced dielectric permittivity of LN2 compared with water. The inversion images of total eight different LN2-VN2 flow patterns are presented and quantitatively evaluated by calculating the relative void fraction error and the correlation coefficient. The results demonstrate that the developed reconstruction technique for ECT has the capacity to reconstruct the phase distribution of the complex LN2-VN2 flow, while the accuracy of the inversion images is significantly influenced by the size of the discrete phase. The influence of the measurement noise on the image quality is also considered in the calculations.

  6. Nasopharyngeal Carcinoma Treated with Precision-Oriented Radiation Therapy Techniques Including Intensity-Modulated Radiotherapy: Preliminary Results

    Directory of Open Access Journals (Sweden)

    Wen-Shan Liu

    2004-02-01

    Full Text Available This paper reports preliminary results with intensity-modulated radiotherapy (IMRT in nasopharyngeal carcinoma (NPC. Between August 2000 and May 2001, we treated 19 patients with NPC using IMRT. Twelve patients had stage I-II disease and seven had stage III-IV disease. Six patients received 9.0-19.8 Gy three-dimensional conformal radiotherapy (3D-CRT before IMRT and 18 patients received a brachytherapy boost after IMRT. The mean follow-up time was 13.0 months. All patients with stage II-IV disease except one received two cycles of chemoradiotherapy with cisplatin and 5-fluorouracil (5-FU during radiotherapy, followed by two to four cycles of chemotherapy after radiotherapy. Tumor response was assessed using clinical examination and computerized tomography or magnetic resonance imaging. The mean doses administered to the gross tumor volume and clinical tumor volume were 70.9 Gy and 63.2 Gy, respectively. The mean doses administered to the right and left parotid glands were 38.1 Gy and 38.6 Gy, respectively. All 19 patients had a complete response of primary and lymph node disease. Grade III mucositis developed during chemoradiotherapy in 15 patients (79%. In addition, clinical grade I xerostomia was recorded in nine patients, grade II in nine, and grade III in one. This study demonstrated that 3D-CRT, IMRT, intracavitary brachytherapy, and chemotherapy are effective and safe methods to treat NPC. Although IMRT treatment spared parotid gland function, its efficacy may be significantly influenced by disease stage and location of the neck lymph nodes. More cases and a longer follow-up to assess survival and complications are planned.

  7. Autofluorescence of pigmented skin lesions using a pulsed UV laser with synchronized detection: clinical results

    DEFF Research Database (Denmark)

    Cheng, Haynes Pak Hay; Svenmarker, Pontus; Tidemand-Lichtenberg, Peter

    2010-01-01

    signal, which may in turn produce high contrast images that improve diagnosis, even in the presence of ambient room light. The synchronized set-up utilizes a compact, diode pumped, pulsed UV laser at 355 nm which is coupled to a CCD camera and a liquid crystal tunable filter. The excitation and image......We report preliminary clinical results of autofluorescence imaging of malignant and benign skin lesions, using pulsed 355 nm laser excitation with synchronized detection. The novel synchronized detection system allows high signal-to-noise ratio to be achieved in the resulting autofluorescence...

  8. Preliminary results with the CLAMSUD pion spectrometer at the Moscow Meson Factory

    International Nuclear Information System (INIS)

    Badala, A.; Barbera, R.; Librizzi, F.; Longhitano, A.; Nicotra, D.; Palmeri, A.; Pappalardo, G.S.; Riggi, F.; Santoro, A.; Turrisi, R.; Aseev, V.; Feschenko, A.; Gavrilov, Yu.; Guber, F.; Golubeva, M.; Karavicheva, T.; Kurepin, A.; Ostroumov, P.; Potapov, V.; Tiflov, V.; Zhuravlev, A.

    1995-01-01

    A magnetic spectrometer has been recently installed at the new proton beam facility of the Moscow Meson Factory, to study charged pion production from proton-nucleus interactions at 200-400 MeV bombarding energy. Preliminary reults obtained during the first runs are reported. The planned physics program is also discussed. (orig.)

  9. Preliminary Results on the Influence of Engineered Artificial Mucus Layer on Phonation

    Science.gov (United States)

    Döllinger, Michael; Gröhn, Franziska; Berry, David A.; Eysholdt, Ulrich; Luegmair, Georg

    2014-01-01

    Purpose: Previous studies have confirmed the influence of dehydration and an altered mucus (e.g., due to pathologies) on phonation. However, the underlying reasons for these influences are not fully understood. This study was a preliminary inquiry into the influences of mucus architecture and concentration on vocal fold oscillation. Method: Two…

  10. Results of Preliminary Tests of PAR Bunch Cleaning

    CERN Document Server

    Yao, Chihyuan; Grelick, Arthur; Lumpkin, Alex H; Sereno, Nicholas S

    2005-01-01

    A particle accumulator ring (PAR) is used at the Advanced Photon Source (APS) to collect multiple linac bunches and compress them into a 0.3-ns (rms) single bunch for booster injection. A 9.77-MHz fundamental rf system and a 117.3-MHz harmonic rf system are employed for initial beam capture and bunch length compression. Satellite bunches with very low charge form due to rf phase drifts or beam loading change. These satellites, when injected into the booster and then into the storage ring (SR), cause bunch impurity at three buckets from the target bucket. Storage ring and booster bunch cleaning was tried but proved to be difficult due to the top-up mode of operation in the storage ring and tune drift in the booster synchrotron. Recently we implemented a PAR bunch-cleaning system with tune-modulated harmonic rf knockout. Preliminary tests gave a measured SR bunch purity of better than 10

  11. 77 FR 33395 - Light-Walled Rectangular Pipe and Tube From Turkey: Notice of Preliminary Results of Antidumping...

    Science.gov (United States)

    2012-06-06

    ... Noksel did not make sales at less than normal value (NV) during the POR. If these preliminary results are... chromium, or 0.30 percent of cobalt, or 0.40 percent of lead, or 1.25 percent of nickel, or 0.30 percent of... questionnaire and 19 CFR 351.414(e)(2), Noksel requested that the reporting period for home market sales be...

  12. The MACHO Project: Preliminary Results from 4 years of SMC observations.

    Science.gov (United States)

    Vandehei, T.; Griest, K.; Lehner, M.; Alcock, C.; Alves, D.; Cook, K.; Marshall, S.; Minniti, D.; Allsman, R.; Axelrod, T.; Freeman, K.; Peterson, B.; Rodgers, A.; Pratt, M.; Becker, A.; Stubbs, C.; Tomaney, A.; Bennett, D.; Quinn, P.; Sutherland, W.; Welch, D.

    1997-12-01

    The MACHO project is a search for dark matter in the form of massive compact halo objects(MACHOs). The project has photometrically monitored tens of millions of stars in the Large Magellanic Cloud (LMC), Small Magellanic Cloud (SMC), and Galactic bulge in search of rare gravitational microlensing events caused by these otherwise invisible objects. Microlensing toward the LMC has allowed powerful statements to be made about the dark population in the halo of our Galaxy, indicating that the MACHO halo fraction could be as high as f=0.5 with a most probable MACHO mass being ~ 0.5Msun. However, to date the LMC has been the only line of sight out of our Galaxy's halo. Clearly, another line of sight would provide a consistency check on these results, as well as another contraint on models of the halo, in particular on halo flattening. The SMC affords us this second line of sight. Here we give a status report on our upcoming 4 year results toward the SMC. We present the results of a preliminary analysis on over 2.2 million stars from 3 square degrees and discuss the implications for the dark matter in the halo of our Galaxy. A detailed analysis of the microlensing candidates toward the SMC, with blending and parallax fits, will be shown. This work is dedicated to the memory of Alex Rodgers.

  13. Persian competing word test: Development and preliminary results in normal children

    Directory of Open Access Journals (Sweden)

    Mohammad Ebrahim Mahdavi

    2008-12-01

    Full Text Available Background and Aim: Assessment of central auditory processing skills needs various behavioral tests in format of a test battery. There is a few Persian speech tests for documenting central auditory processing disorders. The purpose of this study was developing a dichotic test formed of one-syllabic words suitable for evaluation of central auditory processing in Persian language children and reporting its preliminary results in a group of normal children.Materials and Methods: Persian words in competing manner test was developed utilizing most frequent monosyllabic words in children storybooks reported in the previous researches. The test was performed at MCL on forty-five normal children (39 right-handed and 6 left-handed aged 5-11 years. The children did not show any obvious problem in hearing, speech, language and learning. Free (n=28 and directed listening (n=17 tasks were investigated.Results: The results show that in directed listening task, there is significant advantage for performance of pre-cued ear relative to opposite side. Right ear advantage is evident in free recall condition. Average performance of the children in directed recall is significantly better than free recall. Average row score of the test increases with the children age.Conclusion: Persian words in competing manner test as a dichotic test, can show major characteristics of dichotic listening and effect of maturation of central auditory system on it in normal children.

  14. Preliminary application in teaching of medical imaging with picture archiving and communication systems

    International Nuclear Information System (INIS)

    Wei Yuqing; Hu Jian; Wang Xuejian; Cao Jun; Tong Juan; Shen Guiquan; Luo Min; Luo Song

    2003-01-01

    Objective: To evaluate PACS (picture archiving and communication systems) in the teaching of medical imaging. Methods: Large screen multimedia reading room and electronic study room were built with GE PACS and Angel RIS (radiology information system) and end-term picture-word work-station. Pictures and words of PACS were unloaded directly for teaching and teaching image bank and test image bank. Results: Large screen multimedia reading room, classroom, and electronic study room were built successfully. Valuable information of nearly 5000 patients in the teaching imaging bank of PACS was accumulated. Classic medical imaging teaching mode was changed. Real-time and multi-mode teaching were realized, and teaching effect was greatly improved. The PACS-based teaching model was accepted pleasantly by students. Conclusion: PACS is very useful to improve the teaching quality of medical imaging and it is worth to popularize

  15. A language for image processing HILLS and its supporting system SDIP

    International Nuclear Information System (INIS)

    Suzuki, H.; Toriwaki, J.

    1984-01-01

    This paper presents a language HILLS and its supporting system SDIP for image processing. HILLS is a key-word type language for describing image processing procedures by using subroutine packages SLIP and SPIDER. SDIP, written in FORTRAN to keep portability, supports programming by HILLS in interactive mode including functions such as editing, translating HILLS into FORTRAN, error detection, and providing manual information. Results of preliminary experiments suggest that HILLS and SDIP are very useful tools for beginners and researchers in application fields of image processing to develop desired image analysis procedures

  16. Fractal-Based Image Analysis In Radiological Applications

    Science.gov (United States)

    Dellepiane, S.; Serpico, S. B.; Vernazza, G.; Viviani, R.

    1987-10-01

    We present some preliminary results of a study aimed to assess the actual effectiveness of fractal theory and to define its limitations in the area of medical image analysis for texture description, in particular, in radiological applications. A general analysis to select appropriate parameters (mask size, tolerance on fractal dimension estimation, etc.) has been performed on synthetically generated images of known fractal dimensions. Moreover, we analyzed some radiological images of human organs in which pathological areas can be observed. Input images were subdivided into blocks of 6x6 pixels; then, for each block, the fractal dimension was computed in order to create fractal images whose intensity was related to the D value, i.e., texture behaviour. Results revealed that the fractal images could point out the differences between normal and pathological tissues. By applying histogram-splitting segmentation to the fractal images, pathological areas were isolated. Two different techniques (i.e., the method developed by Pentland and the "blanket" method) were employed to obtain fractal dimension values, and the results were compared; in both cases, the appropriateness of the fractal description of the original images was verified.

  17. Automatic three-dimensional model for protontherapy of the eye: Preliminary results

    International Nuclear Information System (INIS)

    Bondiau, Pierre-Yves; Malandain, Gregoire; Chauvel, Pierre; Peyrade, Frederique; Courdi, Adel; Iborra, Nicole; Caujolle, Jean-Pierre; Gastaud, Pierre

    2003-01-01

    Recently, radiotherapy possibilities have been dramatically increased by software and hardware developments. Improvements in medical imaging devices have increased the importance of three-dimensional (3D) images as the complete examination of these data by a physician is not possible. Computer techniques are needed to present only the pertinent information for clinical applications. We describe a technique for an automatic 3D reconstruction of the eye and CT scan merging with fundus photographs (retinography). The final result is a 'virtual eye' to guide ocular tumor protontherapy. First, we make specific software to automatically detect the position of the eyeball, the optical nerve, and the lens in the CT scan. We obtain a 3D eye reconstruction using this automatic method. Second, we describe the retinography and demonstrate the projection of this modality. Then we combine retinography with a reconstructed eye, using a CT scan to get a virtual eye. The result is a computer 3D scene rendering a virtual eye into a skull reconstruction. The virtual eye can be useful for the simulation, the planning, and the control of ocular tumor protontherapy. It can be adapted to treatment planning to automatically detect eye and organs at risk position. It should be highlighted that all the image processing is fully automatic to allow the reproduction of results, this is a useful property to conduct a consistent clinical validation. The automatic localization of the organ at risk in a CT scan or an MRI by automatic software could be of great interest for radiotherapy in the future for comparison of one patient at different times, the comparison of different treatments centers, the possibility of pooling results of different treatments centers, the automatic generation of doses-volumes histograms, the comparison between different treatment planning for the same patient and the comparison between different patients at the same time. It will also be less time consuming

  18. Preliminary clinical results of locoregional hyperthermia for primary and secondary bone tumors

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, J.L.; Nagata, Yasushi; Kanamori, Shuichi; Mitsumori, Michihide; Okuno, Yoshishige; Horii, Naotoshi; Nishimura, Yasumasa; Masunaga, Shinitiro; Hiraoka, Masahiro [Kyoto Univ. (Japan). Graduate School of Medicine

    2000-03-01

    Nineteen primary and secondary bone tumors in 16 patients were treated with hyperthermia plus radiotherapy and/or chemotherapy between 1982 and 1997 at Kyoto University Hospital. The thermometric and clinical results were analyzed retrospectively. In 55 of 86 hyperthermia sessions, the intratumor temperature was measured using a thermometer. Of the 19 tumors, 16 (84%) received heat treatment 4-7 times, and 3 (16%) received 1 or 2 treatments of hyperthermia. The mean maximum, mean minimum and average intratumor temperatures were 42.9, 40.4 and 41.6 deg C, respectively, and 12 (67%) reached a tumor maximum temperature above 42.5 deg C. The durations that intratumor points exceeded 42, 41 and 40 deg C were 27, 34 and 38 min, respectively. The local tumor response to treatment was assessed using X-ray computed tomography. The local response rate was 16% and the local pain relief rate was 63%. The 1-year cumulative survival rate was 60%. Our preliminary results indicated that thermoradiotherapy and thermochemotherapy are clinicaly feasible and potentially beneficial in the management of locally advanced bone tumors. (author)

  19. Results from the Coded Aperture Neutron Imaging System (CANIS)

    International Nuclear Information System (INIS)

    Brubaker, Erik; Steele, John T.; Brennan, James S.; Hilton, Nathan R.; Marleau, Peter

    2010-01-01

    Because of their penetrating power, energetic neutrons and gamma rays (∼1 MeV) offer the best possibility of detecting highly shielded or distant special nuclear material (SNM). Of these, fast neutrons offer the greatest advantage due to their very low and well understood natural background. We are investigating a new approach to fast-neutron imaging- a coded aperture neutron imaging system (CANIS). Coded aperture neutron imaging should offer a highly efficient solution for improved detection speed, range, and sensitivity. We have demonstrated fast neutron and gamma ray imaging with several different configurations of coded masks patterns and detectors including an 'active' mask that is composed of neutron detectors. Here we describe our prototype detector and present some initial results from laboratory tests and demonstrations.

  20. Evaluation of diagnostic radiology services in five Latin American countries: Results for mammography

    International Nuclear Information System (INIS)

    Brandan, M.E.; Caspani, C.E.M.; Mora, R. de la; Miranda, A.A.; Plazas, M.-C.; Borras, C.

    2001-01-01

    Under the auspices of PAHO/WHO, a multicentric investigation is carried out in five Latin American countries. Its aim is to correlate quality indicators of radiology services with the accuracy of the radiological interpretation as determined by a panel of experts. We present preliminary results from mammographic imaging facilities, which indicate that the failure to comply with the international standards of quality control produces images of unacceptable quality, as measured either by using a phantom or by an independent evaluation of the clinical images. (author)

  1. The preliminary study of CT cerebral perfusion imaging in transient ischemic attacks

    International Nuclear Information System (INIS)

    Lu Jie; Li Kuncheng; Du Xiangying

    2002-01-01

    Objective: To probe the application of CT cerebral perfusion imaging on transient ischemic attacks (TIA). Methods: Conventional CT and CT cerebral perfusion imaging were performed on 5 normal adults and 20 patients with clinically diagnosed TIA. After regular CT examination, dynamic scans of 40 seconds were performed on selected slice (usually on the basal ganglia slice), while 40 ml non-ionic contrast material were bolus injected through antecubital vein with. These dynamic images were processed with the 'Perfusion CT' software package on a PC based workstation. Cerebral blood flow (CBF) and time to peak (TP) enhancement were measured within specific regions of the brain on CT perfusion images. Quantitative analysis was performed for these images. Results: A gradient of perfusion between gray matter and white matter was showed on cT perfusion images in normal adults and TIA patients. CBF and TP for normal cortical and white matter were 378.2 ml·min -1 ·L -1 , 7.8 s and 112.5 ml·min -1 ·L -1 , 9.9 s, respectively. In 20 cases with TIA, persisting abnormal perfusion changes corresponding to clinical symptoms were found in 15 cases with prolonged TP. Other 5 cases showed normal results. TP of affected side (11.8 +- 4.4) s compared with that of the contralateral side (9.1 +- 3.1) s was significantly prolonged (t = 5.277, P -1 · -1 ] and contralateral side [(229.1 +- 41.4) ml·min -1 ·L -1 ]. Conclusion: Perfusion CT provides valuable hemodynamic information and shows the extent of perfusion disturbances for patients with TIA

  2. Constraining back-arc basin formation in the eastern Coral Sea: preliminary results from the ECOSAT voyage

    Science.gov (United States)

    Seton, M.; Williams, S.; Mortimer, N. N.; Meffre, S.; Moore, J.; Micklethwaite, S.; Zahirovic, S.

    2013-12-01

    The eastern Coral Sea region is an underexplored area at the northeastern corner of the Australian plate, where long-lived interaction between the Pacific and Australian plate boundaries has resulted in an intricate assemblage of deep oceanic basins and ridges, continental fragments and volcanic products. A paucity of marine geophysical and geological data from this complex region has resulted in the lack of a clear conceptual framework to describe its formation, ultimately affecting our understanding of the connection between the plate boundaries of the SW Pacific and SE Asia. In particular, the tectonic relationship between two back-arc basins, the Santa Cruz and d'Entrecasteaux Basins, and the South Rennell Trough, has yet to be resolved. In October-November, 2012, we collected 6,200 km of marine magnetic, 6,800 km of gravity and over 13,600 km2 of swath bathymetry data from the eastern Coral Sea onboard the RV Southern Surveyor. A complementary dredging program yielded useful samples from 14 seafloor sites. Our preliminary geochemical interpretation of the dredge samples obtained from the South Rennell Trough reveal volcanic rocks resembling MORB or BABB-type basalts, similar in composition to the recently re-analysed and dated ORSTOM dredges from the area that yielded ~28 Ma MORB-like basalts. Swath bathymetry profiles from the Santa Cruz Basin reveal that the South Rennell Trough extends into this basin, with seafloor spreading fabric being parallel to the trough. Preliminary analysis of the three full and four partial new magnetic anomaly profiles across the Santa Cruz Basin, coupled with limited existing profiles, reveals that the basin may have formed between Chrons 13-18 (~32-38 Ma), with an extinct spreading ridge along the inferred continuation of the South Rennell Trough, consistent with ORSTOM age dates. Our results suggest that the South Rennell Trough is an extinct southwestward propagating spreading ridge, which may have initiated along a pre

  3. Preliminary In-Vivo Evaluation of Convex Array Synthetic Aperture Imaging

    DEFF Research Database (Denmark)

    Pedersen, Morten Høgholm; Gammelmark, Kim; Jensen, Jørgen Arendt

    2004-01-01

    of STA imaging in comparison to conventional imaging. The purpose is to evaluate whether STA imaging is feasible in-vivo. and whether the image quality obtained is comparable to traditional scanned imaging in terms of penetration depth, spatial resolution, contrast resolution, and artifacts. Acquisition...... was done using our RASMUS research scanner and a 5.5 MHz convex array transducer. STA imaging applies spherical wave emulation using multi-element subapertures and a 20 mus linear FM signal as excitation pulse. For conventional imaging a 64 element aperture was used in transmit and receive with a 1.5 cycle...

  4. Characteristics of bone marrow with dynamic contrast-enhanced MR imaging in patients with haematological malignancies: preliminary results

    International Nuclear Information System (INIS)

    Zhang Lei; Yang Zhenyan; Pitman, A.G.

    2007-01-01

    Objective: To determine whether dynamic contrast-enhanced MR (DCE-MRI) can successfully predict the status of diffusely abnormal bone marrow, and so obviate some bone marrow biopsies done for this indication. Methods: DCE-MRI was performed in 25 patients with proven or known haematological malignancies. Time-signal intensity curves (TIC) analysis was generated from the region of the iliac crest corresponding to the planned biopsy site. Enhancement characteristics were analyzed, including peak enhance ratio (PER), maximum slope (Slope max ), time to peak (TTP), and mean time (MT). The parameters of the marrow histology included cellularity and tumour fraction (TF). Results: The median of PER, Slope max , TTP, and MT in bone marrow with haematological malignancies were 0.27, 0.21 s -1 , 79.08 s and 84.43 s, respectively. The median of DCE-MR variation in bone marrow for hypo-, normal, and hyper-, cellularity groups were PER (0.29, 0.24, 1.15), Slope max (0.20 s -1 , 0.21 s -1 1.28 s -1 ), TTP (96.67 s, 83.49 s, 25.52 s), MT(77.52 s, 86.25 s, 84.34 s), respectively. The median of PER, Slope max , TTP, and MT in bone marrow for the tumor recurrence group and the remission group were 0.32, 0.28 s -1 , 68.66 s, 84.34 s, and 0.20, 0.20 s -1 , 85.85 s, 84.52 s, respectively. There was significant difference for mean PER value between the tumor recurrence group and the remission group (P = 0.02). But there were no significant difference for mean S1ope max , TFP, and MT values between the tumor recurrence group and the remission group (P>0.05). A positive correlation was found between PER and cellularity (r=0.564, P=0.003), between S1ope max and cellularity (r=0.478, P=0.016), between MT and cellularity (r=0.186). A negative correlation was found between TTP and cellularity (r=-0.222). A positive correlation was found between PER and TF (r=0.561, P=0.004), between S1ope max and TF(r=0.318, P=0.121), between MT and TF (r=0.207, P>0.05). A negative correlation was found

  5. Posterior perineal support as treatment for anal fissures--preliminary results with a new toilet seat device.

    Science.gov (United States)

    Tan, Kok-Yang; Seow-Choen, Francis; Hai, Chew Heng; Thye, Gan Kok

    2009-03-01

    Anal fissures can cause morbidity in an otherwise healthy young patient. The process of evacuation results in stretching and descent of the anoderm and perineum especially posteriorly. Posterior perineal support may provide counter pressure at the posterior aspect of the pelvic floor, balancing the pressure exerted by the faeces on the anal wall, thus improving evacuation and reducing the trauma associated with it, and reducing symptoms of anal fissures. Symptoms of constipation may also be reduced secondarily. We report the preliminary results with a novel, simple and noninvasive method of treatment provided by a toilet seat device. A prospective study was performed in 32 patients. The study was designed mainly to investigate the patients' subjective perceptions of their symptoms related to anal fissures and constipation. Questionnaires were provided to patients before, during and after treatment. The study revealed statistically significant improvement in pain, bleeding, symptoms of constipation and abdominal discomfort after 3 months usage of the device. The odds of patients perceiving an improvement in symptoms were also significantly increased after 3 months of treatment compared to 2 weeks of treatment. This preliminary study revealed that a posterior perineal support device can bring about significant improvement in the symptoms of patients with anal fissures. There may also be secondary benefits of a reduction in the symptoms of constipation. Although not conclusive, these results should serve as a springboard for further research into this area.

  6. 76 FR 62761 - Stainless Steel Bar From India: Extension of Time Limit for the Preliminary Results of the 2010...

    Science.gov (United States)

    2011-10-11

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-533-810] Stainless Steel Bar From India: Extension of Time Limit for the Preliminary Results of the 2010-2011 Antidumping Duty... review of the antidumping duty order on stainless steel bar from India, covering the period February 1...

  7. Subclinical myocardial dysfunction by tissue Doppler echocardiography in primary antiphospholipid syndrome: Preliminary results

    Directory of Open Access Journals (Sweden)

    Tarcila Fontes de Lima Gomes Lucena

    2018-01-01

    Conclusion: The present study demonstrated subclinical myocardial dysfunction using TDI in asymptomatic PAPS patients. TDI is non-invasive and cost effective. Prospective studies including a large number of participants in order to confirm these preliminary data are needed.

  8. Polarimetry at 1.3 mm using MILLIPOL - methods and preliminary results for Orion

    International Nuclear Information System (INIS)

    Barvainis, R.; Clemens, D.P.; Leach, R.

    1988-01-01

    This paper describes a polarimeter for use at wavelengths near 1 mm, designed to be self-contained and portable. Only minor modifications should be required to adapt this instrument for use on any of several millimeter and submillimeter telescopes. The polarimeter system and data-taking techniques are described, and a preliminary measurement is reported of the polarized dust emission from the Orion KL region at 1.3 mm using the NRAO 12 m telescope. The results are similar to previous polarization measurements of Orion at far-infrared and submillimeter wavelengths. The magnetic field direction implied by the polarization position angle is parallel to that found in the surrounding Orion region using optical and near- to midinfrared polarimetric techniques. 17 references

  9. Correlating element atmospheric deposition and cancer mortality in Portugal: Data handling and preliminary results

    International Nuclear Information System (INIS)

    Sarmento, S.; Wolterbeek, H.Th.; Verburg, T.G.; Freitas, M.C.

    2008-01-01

    This study, framed within geographical epidemiology, presents preliminary findings concerning the association between the concentrations of chemical elements obtained through atmospheric biomonitoring with lichens and cancer mortality in the Portuguese population. Exploratory analyses were performed to identify potential confounders for the relationships between chemical elements and neoplasm mortality and to assess the extent of their interference. The results of this study highlight some methodological and conceptual difficulties inherent to observational and geographical studies, in the specific context of the Portuguese population, and the challenge posed by the large numbers of pollutants considered. - Relationship between chemical elements and mortality from neoplasms in the Portuguese population and the effect of confounders

  10. Natural Gamma Emitters after a Selective Chemical Separation of a TENORM residue: Preliminary Results

    International Nuclear Information System (INIS)

    Alves de Freitas, Antonio; Abrao, Alcidio; Godoy dos Santos, Adir Janete; Pecequilo, Brigitte Roxana Soreanu

    2008-01-01

    An analytical procedure was established in order to obtain selective fractions containing radium isotopes ( 228 Ra), thorium ( 232 Th), and rare earths from RETOTER (REsiduo de TOrio e TErras Raras), a solid residue rich in rare earth elements, thorium isotopes and small amount of natural uranium generated from the operation of a thorium pilot plant for purification and production of pure thorium nitrate at IPEN -CNEN/SP. The paper presents preliminary results of 228 Ra, 226 Ra, 238 U, 210 Pb, and 40 K concentrations in the selective fractions and total residue determined by high-resolution gamma spectroscopy, considering radioactive equilibrium of the samples

  11. Matrix-based image reconstruction methods for tomography

    International Nuclear Information System (INIS)

    Llacer, J.; Meng, J.D.

    1984-10-01

    Matrix methods of image reconstruction have not been used, in general, because of the large size of practical matrices, ill condition upon inversion and the success of Fourier-based techniques. An exception is the work that has been done at the Lawrence Berkeley Laboratory for imaging with accelerated radioactive ions. An extension of that work into more general imaging problems shows that, with a correct formulation of the problem, positron tomography with ring geometries results in well behaved matrices which can be used for image reconstruction with no distortion of the point response in the field of view and flexibility in the design of the instrument. Maximum Likelihood Estimator methods of reconstruction, which use the system matrices tailored to specific instruments and do not need matrix inversion, are shown to result in good preliminary images. A parallel processing computer structure based on multiple inexpensive microprocessors is proposed as a system to implement the matrix-MLE methods. 14 references, 7 figures

  12. Artworks characterization at THz frequencies: preliminary results via the Fiber-Coupled Terahertz Time Domain System

    Science.gov (United States)

    Catapano, Ilaria; Soldovieri, Francesco

    2015-04-01

    spectra, while imaging includes THz tomography and it is considered to obtain non-invasive cross-section images of the artwork under test. Preliminary experiments regarding laboratory designed objects and not precious artworks have been carried out at the IREA laboratory mainly to trace measurements protocols and deeply investigate the diagnostic capabilities of the FICO system. The obtained results will be illustrated and discussed at the conference. REFERENCES [1] K. Fukunaga and I. Hosako, Innovative non-invasive analysis techniques for cultural heritage using terahertz technology, C.R. Physique 11, 519-526, 2010. [2] M. Perenzoni and D. J. Paul, Physics and Applications of Terahertz Radiation, Springer Series in Optical Sciences 173, 2014. [3] J.P. Guillet, B. Recur, L. Frederique, B. Bousquet, L. Canioni, I. Manek-Hönninger, P. Desbarats, P.Mounaix, Review of Terahertz Tomography Techniques, J. Infrared MilliTerahz Waves 35, 382-411, 2014.

  13. Porous titanium obtained by a new powder metallurgy technique: Preliminary results of human osteoblast adhesion on surface polished substrates.

    Science.gov (United States)

    Biasotto, M; Ricceri, R; Scuor, N; Schmid, C; Sandrucci, M A; Di Lenarda, R; Matteazzi, P

    2003-01-01

    This study concerns a novel powder metallurgy method for producing porous titanium (pTi) exhibiting high mechanical properties. The preparation procedure consisted of the following stages: first, the preparation of Ti and titanium hydride (TiH2) powder mixtures and their consolidation with a cold isostatic press, followed by a sintering of the green bodies performed with hot isostatic press (HIP) equipment. Thermal decomposition in controlled environment of the TiH2 phase results in the foam structure. The resulting porosity percolates with a volume fraction of approximately 20%. The final material exhibits interesting mechanical properties, comparable to those of full density titanium (between grade 2 and grade 3), with the advantage of a minor density. The samples produced were tested to verify their biological response by studying the effectiveness of osteoblast adhesion and growth. In this preliminary study, osteoblastic cell morphology was investigated and compared to that observed on fully dense commercially pure titanium (Ti-cp) (ASTM, grade 3). The preliminary results were promising regarding cellular adhesion and spreading. (Journal of Applied Biomaterials & Biomechanics 2003; 1: 172-7).

  14. Recent progress on microwave imaging technology and new physics results

    International Nuclear Information System (INIS)

    Tobias, Benjamin; Luhmann, Neville C. Jr.; Domier, Calvin W.

    2011-01-01

    Techniques for visualizing turbulent flow in nature and in the laboratory have evolved over half a millennium from Leonardo da Vinci's sketches of cascading waterfalls to the advanced imaging technologies which are now pervasive in our daily lives. Advancements in millimeter wave imaging have served to usher in a new era in plasma diagnostics, characterized by ever improving 2D, and even 3D, images of complex phenomena in tokamak and stellarator plasmas. Examples at the forefront of this revolution are electron cyclotron emission imaging (ECEI) and microwave imaging reflectometry (MIR). ECEI has proved to be a powerful tool as it has provided immediate physics results following successful diagnostic installations on TEXTOR, ASDEX-U, DIII-D, and KSTAR. Recent results from the MIR system on LHD are demonstrating that this technique has the potential for comparable impact in the diagnosis of electron density fluctuations. This has motivated a recent resurgence in MIR research and development, building on a prototype system demonstrated on TEXTOR, toward the realization of combined ECEI/MIR systems on DIII-D and KSTAR for simultaneous imaging of electron temperature and density fluctuations. The systems discussed raise the standard for fusion plasma diagnostics and present a powerful new capability for the validation of theoretical models and numerical simulations. (author)

  15. Extremity exposure in nuclear medicine: Preliminary results of a European study

    International Nuclear Information System (INIS)

    Merce, M. S.; Ruiz, N.; Barth, I.; Carnicer, A.; Donadille, L.; Ferrari, P.; Fulop, M.; Ginjaume, M.; Gualdrini, G.; Krim, S.; Mariotti, F.; Ortega, X.; Rimpler, A.; Vanhavere, F.; Baechler, S.

    2011-01-01

    The Work Package 4 of the ORAMED project, a collaborative project (2008-11) supported by the European Commission within its seventh Framework Programme, is concerned with the optimisation of the extremity dosimetry of medical staff in nuclear medicine. To evaluate the extremity doses and dose distributions across the hands of medical staff working in nuclear medicine departments, an extensive measurement programme has been started in 32 nuclear medicine departments in Europe. This was done using a standard protocol recording all relevant information for radiation exposure, i.e. radiation protection devices and tools. This study shows the preliminary results obtained for this measurement campaign. For diagnostic purposes, the two most-used radionuclides were considered: 99m Tc) and 18 F. For therapeutic treatments, Zevalin R and DOTATOC (both labelled with 90 Y) were chosen. Large variations of doses were observed across the hands depending on different parameters. Furthermore, this study highlights the importance of the positioning of the extremity dosemeter for a correct estimate of the maximum skin doses. (authors)

  16. Preliminary studies of monoclonal antibody lymphoscintigraphy in malignant melanoma

    International Nuclear Information System (INIS)

    Nelp, W.B.; Eary, J.F.; Jones, R.F.; Hellstrom, K.E.; Hellstrom, I.; Beaumier, P.L.; Krohn, K.A.

    1987-01-01

    Lymphoscintigraphy was performed at 3 and 20 hr following subcutaneous injection of 131 I anti-melanoma antibody (Fab) in 11 patients who had surgical resection of lymph nodes (neck, axilla, groin) at 24 hr for suspected metastatic melanoma. Comparable amounts of 125 I nonspecific control antibody (Fab) were co-administered. Six patients had nodal metastases and three showed positive images at both time periods. Five patients had no metastases though one was image positive. Four other nondiseased inguinal node groups were image negative. A total of 28 tumored nodes and 110 normal nodes were removed, counted and histologically examined. All metastatic tumors expressed antigen against which the specific Fab was directed. The concentrations of both specific and nonspecific Fab were similar in tumored nodes and both were significantly greater than in normal nodes showed essentially identical intranodal spatial distribution of the specific and control Fab in areas containing tumor. These preliminary results suggest the increased concentration of murine immunoglobulin (Fab) retained in diseased nodes was a nonspecific phenomenon

  17. High dose rate brachytherapy (HDRB) in prostate cancer - technique description and preliminary results

    International Nuclear Information System (INIS)

    Cordova Junior, Ardo Lotar; Salvajoli, Joao Victor; Pelizzon, Antonio CAssio Assis; Cecilio, Paulo Jose

    1998-01-01

    Describe the technique and preliminary results of high dose rate brachytherapy (HDRB) in localized prostate cancer. Subjects methods: Between March, 1997 and April, 1998, 26 patients were treated with external beam radiotherapy (45 to 50.4 Gy - 1.8 Gy per day) and implants (16 Gy in 2 days - twice a day). Median age was 68 years. The distribution by clinical stage was: 5 T1c, 9 T2a, 10 T2b and 2 T3a. Median initial PSA was 16 ng/ml. Results: With a median follow-up of 4 months, 85% of patients showed normal levels of PSA, with a median of 0.6 ng/ml, 60 to 90 days after treatment. Dysuria grades 1 and 2 and proctitis grade 1 were found in 11,3 and 5 patients, respectively. Conclusion: The method is safe, with acceptable early side effects. Longer follow-up is necessary before drawing any conclusions. (author)

  18. Diffusion-weighted MR imaging of transplanted kidneys: Preliminary report.

    Science.gov (United States)

    Wypych-Klunder, Katarzyna; Adamowicz, Andrzej; Lemanowicz, Adam; Szczęsny, Wojciech; Włodarczyk, Zbigniew; Serafin, Zbigniew

    2014-01-01

    An aim of this study was to assess the feasibility of DWI in the early period after kidney transplantation. We also aimed to compare ADC and eADC values in the cortex and medulla of the kidney, to estimate image noise and variability of measurements, and to verify possible relation between selected labolatory results and diffusion parameters in the transplanted kidney. Examinations were performed using a 1.5 T MR unit. DWI (SE/EPI) was performed in the axial plane using b-values of 600 and 1000. ADC and eADC measurements were performed in four regions of interest within the renal cortex and in three regions within the medulla. Relative variability of results and signal-to-noise ratio (SNR) were calculated. The analysis included 15 patients (mean age 52 years). The mean variability of ADC was significantly lower than that of eADC (6.8% vs. 10.8%, respectively; p30 ml/min./1.73 m(2) (p<0.05). Diffusion-weighted imaging of transplanted kidneys is technically challenging, especially in patients in the early period after transplantation. From a technical point of view, the best quality parameters offer quality ADC measurement in the renal cortex using b1000. ADC and eADC values in the renal cortex measured at b1000 present a relationship with eGFR.

  19. Preliminary test results from a free-piston Stirling engine technology demonstration program to support advanced radioisotope space power applications

    International Nuclear Information System (INIS)

    White, Maurice A.; Qiu Songgang; Augenblick, Jack E.

    2000-01-01

    Free-piston Stirling engines offer a relatively mature, proven, long-life technology that is well-suited for advanced, high-efficiency radioisotope space power systems. Contracts from DOE and NASA are being conducted by Stirling Technology Company (STC) for the purpose of demonstrating the Stirling technology in a configuration and power level that is representative of an eventual space power system. The long-term objective is to develop a power system with an efficiency exceeding 20% that can function with a high degree of reliability for up to 15 years on deep space missions. The current technology demonstration convertors (TDC's) are completing shakedown testing and have recently demonstrated performance levels that are virtually identical to projections made during the preliminary design phase. This paper describes preliminary test results for power output, efficiency, and vibration levels. These early results demonstrate the ability of the free-piston Stirling technology to exceed objectives by approximately quadrupling the efficiency of conventional radioisotope thermoelectric generators (RTG's)

  20. Preliminary test results from a free-piston Stirling engine technology demonstration program to support advanced radioisotope space power applications

    Science.gov (United States)

    White, Maurice A.; Qiu, Songgang; Augenblick, Jack E.

    2000-01-01

    Free-piston Stirling engines offer a relatively mature, proven, long-life technology that is well-suited for advanced, high-efficiency radioisotope space power systems. Contracts from DOE and NASA are being conducted by Stirling Technology Company (STC) for the purpose of demonstrating the Stirling technology in a configuration and power level that is representative of an eventual space power system. The long-term objective is to develop a power system with an efficiency exceeding 20% that can function with a high degree of reliability for up to 15 years on deep space missions. The current technology demonstration convertors (TDC's) are completing shakedown testing and have recently demonstrated performance levels that are virtually identical to projections made during the preliminary design phase. This paper describes preliminary test results for power output, efficiency, and vibration levels. These early results demonstrate the ability of the free-piston Stirling technology to exceed objectives by approximately quadrupling the efficiency of conventional radioisotope thermoelectric generators (RTG's). .