WorldWideScience

Sample records for preliminary dose-finding studies

  1. Analysis and planning of dose-finding studies with active control

    International Nuclear Information System (INIS)

    Helms, Hans-Joachim

    2014-01-01

    In the clinical development of radiopharmaceuticals the dose finding plays an important role. The contribution is focused on the evaluation and planning of dose finding studies with active control. It is of primary interest to find the lowest dose that yields the same efficacy as the active control. Besides the target dose confidence intervals are of importance to describe the quality of the target dose estimation. The calculation of case numbers and the determination of the dose steps to be studied are challenging under practical conditions. The contribution covers the demonstration of the statistical model the parameter estimation and the asymptotic properties based on maximum likelihood theory, the spline-based evaluation of nonlinear dose finding studies with active control and the planning of design and number of cases.

  2. Identifying the most successful dose (MSD) in dose-finding studies in cancer.

    Science.gov (United States)

    Zohar, Sarah; O'Quigley, John

    2006-01-01

    For a dose finding study in cancer, the most successful dose (MSD), among a group of available doses, is that dose at which the overall success rate is the highest. This rate is the product of the rate of seeing non-toxicities together with the rate of tumor response. A successful dose finding trial in this context is one where we manage to identify the MSD in an efficient manner. In practice we may also need to consider algorithms for identifying the MSD which can incorporate certain restrictions, the most common restriction maintaining the estimated toxicity rate alone below some maximum rate. In this case the MSD may correspond to a different level than that for the unconstrained MSD and, in providing a final recommendation, it is important to underline that it is subject to the given constraint. We work with the approach described in O'Quigley et al. [Biometrics 2001; 57(4):1018-1029]. The focus of that work was dose finding in HIV where both information on toxicity and efficacy were almost immediately available. Recent cancer studies are beginning to fall under this same heading where, as before, toxicity can be quickly evaluated and, in addition, we can rely on biological markers or other measures of tumor response. Mindful of the particular context of cancer, our purpose here is to consider the methodology developed by O'Quigley et al. and its practical implementation. We also carry out a study on the doubly under-parameterized model, developed by O'Quigley et al. but not

  3. Preliminary results for avelumab plus axitinib as first-line therapy in patients with advanced clear-cell renal-cell carcinoma (JAVELIN Renal 100): an open-label, dose-finding and dose-expansion, phase 1b trial.

    Science.gov (United States)

    Choueiri, Toni K; Larkin, James; Oya, Mototsugu; Thistlethwaite, Fiona; Martignoni, Marcella; Nathan, Paul; Powles, Thomas; McDermott, David; Robbins, Paul B; Chism, David D; Cho, Daniel; Atkins, Michael B; Gordon, Michael S; Gupta, Sumati; Uemura, Hirotsugu; Tomita, Yoshihiko; Compagnoni, Anna; Fowst, Camilla; di Pietro, Alessandra; Rini, Brian I

    2018-04-01

    The combination of an immune checkpoint inhibitor and a VEGF pathway inhibitor to treat patients with advanced renal-cell carcinoma might increase the clinical benefit of these drugs compared with their use alone. Here, we report preliminary results for the combination of avelumab, an IgG1 monoclonal antibody against the programmed cell death protein ligand PD-L1, and axitinib, a VEGF receptor inhibitor approved for second-line treatment of advanced renal-cell carcinoma, in treatment-naive patients with advanced renal-cell carcinoma. The JAVELIN Renal 100 study is an ongoing open-label, multicentre, dose-finding, and dose-expansion, phase 1b study, done in 14 centres in the USA, UK, and Japan. Eligible patients were aged 18 years or older (≥20 years in Japan) and had histologically or cytologically confirmed advanced renal-cell carcinoma with clear-cell component, life expectancy of at least 3 months, an Eastern Cooperative Oncology Group performance status of 1 or less, received no previous systemic treatment for advanced renal cell carcinoma, and had a resected primary tumour. Patients enrolled into the dose-finding phase received 5 mg axitinib orally twice daily for 7 days, followed by combination therapy with 10 mg/kg avelumab intravenously every 2 weeks and 5 mg axitinib orally twice daily. Based on the pharmacokinetic data from the dose-finding phase, ten additional patients were enrolled into the dose-expansion phase and assigned to this regimen. The other patients in the dose-expansion phase started taking combination therapy directly. The primary endpoint was dose-limiting toxicities in the first 4 weeks (two cycles) of treatment with avelumab plus axitinib. Safety and antitumour activity analyses were done in all patients who received at least one dose of avelumab or axitinib. This trial is registered with ClinicalTrials.gov, number NCT02493751. Between Oct 30, 2015, and Sept 30, 2016, we enrolled six patients into the dose-finding phase and 49 into the

  4. Sensitivity of dose-finding studies to observation errors.

    Science.gov (United States)

    Zohar, Sarah; O'Quigley, John

    2009-11-01

    The purpose of Phase I designs is to estimate the MTD (maximum tolerated dose, in practice a dose with some given acceptable rate of toxicity) while, at the same time, minimizing the number of patients treated at doses too far removed from the MTD. Our purpose here is to investigate the sensitivity of conclusions from dose-finding designs to recording or observation errors. Certain toxicities may go undetected and, conversely, certain non-toxicities may be incorrectly recorded as dose-limiting toxicities. Recording inaccuracies would be expected to have an influence on final and within trial recommendations and, in this paper, we study in greater depth this question. We focus, in particular on three designs used currently; the standard '3+3' design, the grouped up-and-down design [M. Gezmu, N. Flournoy, Group up-and-down designs for dose finding. Journal of Statistical Planning and Inference 2006; 136 (6): 1749-1764.] and the continual reassessment method (CRM, [J. O'Quigley, M. Pepe, L. Fisher, Continual reassessment method: a practical design for phase 1 clinical trials in cancer. Biometrics 1990; 46 (1): 33-48.]). A non-toxicity incorrectly recorded as a toxicity (error of first kind) has a greater influence in general than the converse (error of second kind). These results are illustrated via figures which suggest that the standard '3+3' design in particular is sensitive to errors of the second kind. Such errors can have a very important impact on drug development in that, if carried through to the Phase 2 and Phase 3 studies, we can significantly increase the probability of failure to detect efficacy as a result of having delivered an inadequate dose.

  5. Sodium phenylbutyrate in Huntington's disease: a dose-finding study.

    Science.gov (United States)

    Hogarth, Penelope; Lovrecic, Luca; Krainc, Dimitri

    2007-10-15

    Transcriptional dysregulation in Huntington's disease (HD) is mediated in part by aberrant patterns of histone acetylation. We performed a dose-finding study in human HD of sodium phenylbutyrate (SPB), a histone deacetylase inhibitor that ameliorates the HD phenotype in animal models. We used a dose-escalation/de-escalation design, using prespecified toxicity criteria and standard clinical and laboratory safety measures. The maximum tolerated dose was 15 g/day. At higher doses, toxicity included vomiting, lightheadedness, confusion, and gait instability. We saw no significant laboratory or electrocardiographic abnormalities. Gene expression changes in blood suggested an inverse dose-response. In conclusion, SPB at 12 to 15 g/day appears to be safe and well-tolerated in human HD. 2007 Movement Disorder Society

  6. High-dose vitamin B6 decreases homocysteine serum levels in patients with schizophrenia and schizoaffective disorders: a preliminary study.

    Science.gov (United States)

    Miodownik, Chanoch; Lerner, Vladimir; Vishne, Tali; Sela, Ben-Ami; Levine, Joseph

    2007-01-01

    Vitamin B6 plays an essential role in the normal functioning of the central nervous system. Normal homocysteine (Hcy) serum level is maintained by remethylation of Hcy to methionine by enzymes that require folic acid and vitamin B12 and by catabolism to cysteine by a vitamin B6-dependent enzyme. These findings may be consistent with the hypothesis that the vitamin B6 status may influence plasma Hcy levels. The aims of this preliminary study were (1) to determine whether a correlation exists between Hcy and vitamin B6 levels in patients with schizophrenia and schizoaffective disorders and (2) to investigate whether treatment with high-dose vitamin B6 may reduce Hcy levels in these patients. In this preliminary study, we enrolled 11 patients with schizophrenia or schizoaffective disorders (7 men and 4 women; mean age +/- SD, 50 +/- 12 years) receiving high doses of vitamin B6 treatment (1200 mg/d) for 12 weeks. Blood samples for the assessment of pyridoxal-5-phosphate and Hcy serum levels were obtained at baseline and after 12 weeks of treatment. Age was significantly positively correlated with Hcy levels at baseline (r = 0.392, P = 0.004). All other parameters, including diagnosis, disease duration, and pyridoxal-5-phosphate serum level, were not correlated with Hcy serum levels at baseline. After vitamin B6 treatment, Hcy serum levels significantly decreased (14.2 +/- 3.4 vs. 11.8 +/- 2.0 micromol/L, respectively, t = 2.679, P = 0.023); this decrease being statistically significant in men but not in women. High doses of vitamin B6 lead to a decrease in Hcy serum level in male patients with schizophrenia or schizoaffective disorder.

  7. Case Example of Dose Optimization Using Data From Bortezomib Dose-Finding Clinical Trials.

    Science.gov (United States)

    Lee, Shing M; Backenroth, Daniel; Cheung, Ying Kuen Ken; Hershman, Dawn L; Vulih, Diana; Anderson, Barry; Ivy, Percy; Minasian, Lori

    2016-04-20

    The current dose-finding methodology for estimating the maximum tolerated dose of investigational anticancer agents is based on the cytotoxic chemotherapy paradigm. Molecularly targeted agents (MTAs) have different toxicity profiles, which may lead to more long-lasting mild or moderate toxicities as well as to late-onset and cumulative toxicities. Several approved MTAs have been poorly tolerated during long-term administration, leading to postmarketing dose optimization studies to re-evaluate the optimal treatment dose. Using data from completed bortezomib dose-finding trials, we explore its toxicity profile, optimize its dose, and examine the appropriateness of current designs for identifying an optimal dose. We classified the toxicities captured from 481 patients in 14 bortezomib dose-finding studies conducted through the National Cancer Institute Cancer Therapy Evaluation Program, computed the incidence of late-onset toxicities, and compared the incidence of dose-limiting toxicities (DLTs) among groups of patients receiving different doses of bortezomib. A total of 13,008 toxicities were captured: 46% of patients' first DLTs and 88% of dose reductions or discontinuations of treatment because of toxicity were observed after the first cycle. Moreover, for the approved dose of 1.3 mg/m(2), the estimated cumulative incidence of DLT was > 50%, and the estimated cumulative incidence of dose reduction or treatment discontinuation because of toxicity was nearly 40%. When considering the entire course of treatment, the approved bortezomib dose exceeds the conventional ceiling DLT rate of 20% to 33%. Retrospective analysis of trial data provides an opportunity for dose optimization of MTAs. Future dose-finding studies of MTAs should take into account late-onset toxicities to ensure that a tolerable dose is identified for future efficacy and comparative trials. © 2016 by American Society of Clinical Oncology.

  8. Preliminary Findings on Rural Homelessness in Ohio.

    Science.gov (United States)

    First, Richard J.; And Others

    This report is designed to present preliminary findings from the first comprehensive study of rural homelessness in the United States. The study was conducted during the first 6 months of 1990, and data were collected from interviews with 921 homeless adults in 21 randomly selected rural counties in Ohio. The sample counties represent 26% of the…

  9. Validation of radiosterilization dose of human skin dressings for burnt treatment: preliminary study

    International Nuclear Information System (INIS)

    Castro, E.

    2008-01-01

    Full text: Due to the need for better materials to treat burnt patients, the Peruvian Institute of Nuclear Energy (IPEN) and the Rosa Guerzoni Chambergo Tissue Bank are collaborating for developing human skin dressings. Skin was procured from living donors, who surgically were performed a dermolipectomy. Exclusion criteria, stated by the Peruvian Organization for Transplant and Donation were observed. Glycerolized human skin dressings were processed at the tissue bank and sent to IPEN, where the gamma irradiation sterilizing dose was determined. The purpose of this work is to validate the radiation sterilization dose delivered to human skin dressings using the IAEA Code of Practice for the Radiation Sterilization of Tissue Allografts: Requirements for Validation and Routine Control. A batch of human skin dressings was tested. Average values of bioburden present in ten samples was 30 UFC/item, obtaining a sub-sterilization dose of 4 kGy. Irradiations were performed in the GammacellExcel 220. Sterility tests performed fulfilled the requirements established by the Code, achieving a validated dose value of 19.7 kGy. This preliminary study, that should be repeated in two other batches of processed human skin, allows to diminish 25 kGy the sterilizing dose to the stated above dose value, in a frame of a quality assurance system that also comprises the processes held at tissue banks previous irradiation. It also permit the availability of these materials in Peruvian hospitals. (Author)

  10. Preliminary data on the effects of low radiation doses on plant life

    International Nuclear Information System (INIS)

    Fabries, M.; Grauby, A.

    1975-01-01

    The initial findings from the experimental low level irradiation of an ecosystem, with references to prior in this field, are studied. Previous research on low radiation doses of the University of Toulouse suggests that living organisms are in equilibrium with the radioactivity levels in their environment. Any decrease or increase in the natural radioactivity level seems to induce modifications in the microbe or plant population studies. The radioactivity level thus appears to be an ecological factor just as temperature, humidity, sunlight, etc... The preliminary experiments were conducted using an artificial radioactive source (Cesium-137) similar to sources likely in the future to cause increased environmental radioactivity from radioactive wastes and nuclear power plants. These experiments reveal an apparent reaction threshold of approximately 50μrad/hour among spontaneous plant populations. Above this dose the individuals show the effects of increased size, reduced size or both effects in turn (wave phenomenon) as the radiation level increases. It is difficult to come to any firm conclusions at the present time. Nevertheless, there seem to be a number of phenomena related to the increase in low level radiation doses. Some reflections on the behavior observed are offered [fr

  11. Doses in mammography. Preliminary study

    International Nuclear Information System (INIS)

    Marquez P, F.; Acosta R, N.; Universidad Nacional Mayor de San Marcos, Lima; Benavente, T.; Universidad Nacional Mayor de San Marcos, Lima; Poma, M.

    2002-01-01

    Mammography is the most important method to detect lesions in the breast with this technique one can detect small tumours before clear clinical symptoms appear. Mammographic image of require high quality standards due that the extremely low contrast between the normal and pathological areas in the breast, eg.g., they have similar attenuation and absorption coefficient. The x-ray mammographic systems, used in this study are Senographe 500t and Senographe DMR, a detector with a RadCal ionization chambers calibrated to the qualities of mammographic x-ray beams, and a breast simulator that is a phantoms of polymethylmethacrylate (PMMA) of several thicknesses with the equivalence of 50% of the glandular tissue. The results obtained indicate that the values of doses at the entrance surface of a breast (DES) are greater the reference value 20 mGy to 5,0 cm of PMMA and the values of the mean glandular dose (MGD) exceed the reference value of 2,1 mGy for 5,1 cm of compressed thick breast. We consider that the values high of the EDS and MGD are due that the x-ray systems no meeting in good condition or for used of x-ray spectra no suitable, so is recommendable be carried out test of quality control to the x-ray systems and also realize studies, or characterize the of x-ray mammographic spectra

  12. Embracing model-based designs for dose-finding trials.

    Science.gov (United States)

    Love, Sharon B; Brown, Sarah; Weir, Christopher J; Harbron, Chris; Yap, Christina; Gaschler-Markefski, Birgit; Matcham, James; Caffrey, Louise; McKevitt, Christopher; Clive, Sally; Craddock, Charlie; Spicer, James; Cornelius, Victoria

    2017-07-25

    Dose-finding trials are essential to drug development as they establish recommended doses for later-phase testing. We aim to motivate wider use of model-based designs for dose finding, such as the continual reassessment method (CRM). We carried out a literature review of dose-finding designs and conducted a survey to identify perceived barriers to their implementation. We describe the benefits of model-based designs (flexibility, superior operating characteristics, extended scope), their current uptake, and existing resources. The most prominent barriers to implementation of a model-based design were lack of suitable training, chief investigators' preference for algorithm-based designs (e.g., 3+3), and limited resources for study design before funding. We use a real-world example to illustrate how these barriers can be overcome. There is overwhelming evidence for the benefits of CRM. Many leading pharmaceutical companies routinely implement model-based designs. Our analysis identified barriers for academic statisticians and clinical academics in mirroring the progress industry has made in trial design. Unified support from funders, regulators, and journal editors could result in more accurate doses for later-phase testing, and increase the efficiency and success of clinical drug development. We give recommendations for increasing the uptake of model-based designs for dose-finding trials in academia.

  13. Preliminary characterization of dose in personnel of interventional radiology

    International Nuclear Information System (INIS)

    Godolfim, Laura Larre; Anes, Mauricio; Bacelar, Alexandre; Lykawka, Rochelle

    2016-01-01

    Exposure to X-rays of Interventional Radiology professionals (IR) impacts in the high dose rate received by these individuals, and there are reports of biological effects of this professional activity. Therefore, it is fomented greater control over the doses received by these workers. This research intends to characterize the doses received by the professionals during IR procedures. We evaluated the doses of radiologists, anesthesiologists and nursing staff of the Hospital de Clinicas de Porto Alegre, through measures with dosimeters of the OSL type, distributed in up to six regions of the body of these professionals. Until now were accompanied 33 cholangiography procedures and 29 embolization procedures. As a preliminary result, it was possible to identify a wide variation between doses of the professionals of the same function in each procedure. In overview, the dose of the professionals presented in descending order as a radiologist 1> radiologist 2 > anesthetist > nursing. (author)

  14. Influence of age and gender in response to {gamma}-radiation in Portuguese individuals using chromosomal aberration assay - Preliminary findings

    Energy Technology Data Exchange (ETDEWEB)

    Martins, V.; Antunes, A.C. [Instituto Tecnologico e Nuclear, Unidade de Proteccao e Seguranca Radiologica, Dosimetry and Radiobiology Group, E.N. 10, Apartado 21, 2686-953 Sacavem (Portugal); Cardoso, J.; Santos, L. [Instituto Tecnologico e Nuclear, Unidade de Proteccao e Seguranca Radiologica, Metrology Laboratory of Ionizing Radiation, E.N. 10, Apartado 21, 2686-953 Sacavem (Portugal); Gil, O. Monteiro, E-mail: octavia.gil@itn.pt [Instituto Tecnologico e Nuclear, Unidade de Proteccao e Seguranca Radiologica, Dosimetry and Radiobiology Group, E.N. 10, Apartado 21, 2686-953 Sacavem (Portugal)

    2011-09-15

    Cytogenetic indicators are widely used in radiobiology to evaluate effects of ionizing radiation since dicentric chromosomes (Dic) are almost exclusively induced by ionizing radiation, and spontaneous frequency of Dic is very low in the healthy general population (about one Dic per 1000 cells). A particular interest of biodosimetry has been not only to obtain absorbed dose estimates using adequate calibration curves, under the assumption that all individuals respond equally to radiation-induced chromosome aberrations, but also to find a way to demonstrate inter-individual radiosensitivity and a possible correlation with age and gender. Thus, the objective of this preliminary work was the evaluation of the influence of age and gender on the outcome of cytogenetic biomarkers after {gamma}-irradiation. Samples of peripheral blood lymphocytes from six healthy, non-smoker, donors from both genders (three men and three women), in the range of 20 to 49 years, were irradiated with doses from 0 Gy to 3 Gy air kerma, using a {sup 60}Co gamma rays source with a dose rate from 170-180 mGy/min. A clear dose-dependent increase in terms of aberrant cells excluding gaps (ACEG) and Dic was observed for all donors. Our preliminary results suggest, in the higher dose level evaluated (3 Gy), a larger intervariability among individuals for Dic, with females apparently more sensitive than males (P<0.05). Considering the different age groups, male donors showed a decrease, with age, for Dic and ACEG at the higher dose and also, for the background level, in case of ACEG. Future work will consider the study of more individuals, from both genders and different ages, in order to verify if this tendency persists and to enable the implementation of a dose-response calibration curve at Instituto Tecnologico e Nuclear for the Portuguese population, to quantify the biological dose in case of a radiological accident or emergency.

  15. Influence of age and gender in response to γ-radiation in Portuguese individuals using chromosomal aberration assay - Preliminary findings

    International Nuclear Information System (INIS)

    Martins, V.; Antunes, A.C.; Cardoso, J.; Santos, L.; Gil, O. Monteiro

    2011-01-01

    Cytogenetic indicators are widely used in radiobiology to evaluate effects of ionizing radiation since dicentric chromosomes (Dic) are almost exclusively induced by ionizing radiation, and spontaneous frequency of Dic is very low in the healthy general population (about one Dic per 1000 cells). A particular interest of biodosimetry has been not only to obtain absorbed dose estimates using adequate calibration curves, under the assumption that all individuals respond equally to radiation-induced chromosome aberrations, but also to find a way to demonstrate inter-individual radiosensitivity and a possible correlation with age and gender. Thus, the objective of this preliminary work was the evaluation of the influence of age and gender on the outcome of cytogenetic biomarkers after γ-irradiation. Samples of peripheral blood lymphocytes from six healthy, non-smoker, donors from both genders (three men and three women), in the range of 20 to 49 years, were irradiated with doses from 0 Gy to 3 Gy air kerma, using a 60 Co gamma rays source with a dose rate from 170-180 mGy/min. A clear dose-dependent increase in terms of aberrant cells excluding gaps (ACEG) and Dic was observed for all donors. Our preliminary results suggest, in the higher dose level evaluated (3 Gy), a larger intervariability among individuals for Dic, with females apparently more sensitive than males (P<0.05). Considering the different age groups, male donors showed a decrease, with age, for Dic and ACEG at the higher dose and also, for the background level, in case of ACEG. Future work will consider the study of more individuals, from both genders and different ages, in order to verify if this tendency persists and to enable the implementation of a dose-response calibration curve at Instituto Tecnologico e Nuclear for the Portuguese population, to quantify the biological dose in case of a radiological accident or emergency.

  16. 2,3,7,8-Tetrachlorodibenzo-P-Dioxin (TCDD) Dose-Response Studies: Preliminary Literature Search Results and Request for Additional Studies

    Science.gov (United States)

    EPA invited the public to comment on the preliminary list of in vivo mammalian dose-response citations for 2,3,7,8 tetrachlorodibenzo-p-dioxin (TCDD). This list was compiled as a first step in the development of EPA’s response to the National Academy of Sciences comments (NAS, 2...

  17. Preliminary assessment of the dose to the interventional radiologist in fluoro-CT-guided procedures

    International Nuclear Information System (INIS)

    Pereira, M. F.; Alves, J. G.; Sarmento, S.; Santos, J. A. M.; Sousa, M. J.; Gouvea, M.; Oliveira, A. D.; Cardoso, J. V.; Santos, L. M.

    2011-01-01

    A preliminary assessment of the occupational dose to the intervention radiologist received in fluoroscopy computerised tomography (CT) used to guide the collection of lung and bone biopsies is presented. The main aim of this work was to evaluate the capability of the reading system as well as of the available whole-body (WB) and extremity dosemeters used in routine monthly monitoring periods to measure per procedure dose values. The intervention radiologist was allocated 10 WB detectors (LiF: Mg, Ti, TLD-100) placed at chest and abdomen levels above and below the lead apron, and at both right and left arms, knees and feet. A special glove was developed with casings for the insertion of 11 extremity detectors (LiF:Mg, Cu, P, TLD-100H) for the identification of the most highly exposed fingers. The H p (10) dose values received above the lead apron (ranged 0.20-0.02 mSv) depend mainly on the duration of the examination and on the placement of physician relative to the beam, while values below the apron are relatively low. The left arm seems to receive a higher dose value. H p (0.07) values to the hand (ranged 36.30-0.06 mSv) show that the index, middle and ring fingers are the most highly exposed. In this study, the wrist dose was negligible compared with the finger dose. These results are preliminary and further studies are needed to better characterise the dose assessment in CT fluoroscopy. (authors)

  18. Preliminary dose assessment of the Chernobyl accident

    International Nuclear Information System (INIS)

    Hull, A.P.

    1987-01-01

    From the major accident at Unit 4 of the Chernobyl nuclear power station, a plume of airborne radioactive fission products was initially carried northwesterly toward Poland, thence toward Scandinavia and into Central Europe. Reports of the levels of radioactivity in a variety of media and of external radiation levels were collected in the Department of Energy's Emergency Operations Center and compiled into a data bank. Portions of these and other data which were obtained directly from published and official reports were utilized to make a preliminary assessment of the extent and magnitude of the external dose to individuals downwind from Chernobyl. Radioactive 131 I was the predominant fission product. The time of arrival of the plume and the maximum concentrations of 131 I in air, vegetation and milk and the maximum reported depositions and external radiation levels have been tabulated country by country. A large amount of the total activity in the release was apparently carried to a significant elevation. The data suggest that in areas where rainfall occurred, deposition levels were from ten to one-hundred times those observed in nearby ''dry'' locations. Sufficient spectral data were obtained to establish average release fractions and to establish a reference spectra of the other nuclides in the release. Preliminary calculations indicated that the collective dose equivalent to the population in Scandinavia and Central Europe during the first year after the Chernobyl accident would be about 8 x 10 6 person-rem. From the Soviet report, it appears that a first year population dose of about 2 x 10 7 person-rem (2 x 10 5 Sv) will be received by the population who were downwind of Chernobyl within the U.S.S.R. during the accident and its subsequent releases over the following week. 32 refs., 14 figs., 20 tabs

  19. Intradermal inactivated poliovirus vaccine: a preclinical dose-finding study.

    Science.gov (United States)

    Kouiavskaia, Diana; Mirochnitchenko, Olga; Dragunsky, Eugenia; Kochba, Efrat; Levin, Yotam; Troy, Stephanie; Chumakov, Konstantin

    2015-05-01

    Intradermal delivery of vaccines has been shown to result in dose sparing. We tested the ability of fractional doses of inactivated poliovirus vaccine (IPV) delivered intradermally to induce levels of serum poliovirus-neutralizing antibodies similar to immunization through the intramuscular route. Immunogenicity of fractional doses of IPV was studied by comparing intramuscular and intradermal immunization of Wistar rats using NanoPass MicronJet600 microneedles. Intradermal delivery of partial vaccine doses induced antibodies at titers comparable to those after immunization with full human dose delivered intramuscularly. The results suggest that intradermal delivery of IPV may lead to dose-sparing effect and reduction of the vaccination cost. Published by Oxford University Press on behalf of the Infectious Diseases Society of America 2014. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  20. Dose finding study of granisetron in patients receiving high-dose cisplatin chemotherapy. The Granisetron Study Group.

    Science.gov (United States)

    Riviere, A.

    1994-01-01

    The efficacy and safety of three different doses of granisetron (2 micrograms kg-1, group A; 10 micrograms kg-1, group B; 40 micrograms kg-1, group C) were compared in a randomised, double-blind study of 157 patients due to receive high-dose cisplatin therapy (mean dose > 97 mg m-2). In each group, up to two 3 mg rescue doses of granisetron were allowed if more than mild nausea or vomiting occurred. In group A 30.8%, in group B 61.5% and in group C 67.9% of patients were complete responders (i.e. no vomiting or nothing worse than mild nausea) during the first 24 h. These differences are significant between groups A and B, and A and C. There were no statistically significant differences in any efficacy variable between the 10 micrograms kg-1 and 40 micrograms kg-1 groups, although in each case the trend favoured the higher dose. Additional rescue doses resulted in resolved or improved symptoms in 95.3% for the first rescue dose and 93.3% for the second. Over the 7 days of the study, 82.7%, 82.7% and 86.8% of patients in groups A, B and C respectively were treated with granisetron alone. Headache was the most common side-effect, reported by 9.6% of patients; the majority of headaches were mild. There was no difference between the treatment groups regarding the adverse event rate. We concluded that prophylactic doses of 10 or 40 micrograms kg-1 lead to a safe and satisfactory degree of control of nausea and vomiting induced by high-dose cisplatin. PMID:8180032

  1. Intradermal Inactivated Poliovirus Vaccine: A Preclinical Dose-Finding Study

    OpenAIRE

    Kouiavskaia, Diana; Mirochnitchenko, Olga; Dragunsky, Eugenia; Kochba, Efrat; Levin, Yotam; Troy, Stephanie; Chumakov, Konstantin

    2014-01-01

    Intradermal delivery of vaccines has been shown to result in dose sparing. We tested the ability of fractional doses of inactivated poliovirus vaccine (IPV) delivered intradermally to induce levels of serum poliovirus-neutralizing antibodies similar to immunization through the intramuscular route. Immunogenicity of fractional doses of IPV was studied by comparing intramuscular and intradermal immunization of Wistar rats using NanoPass MicronJet600 microneedles. Intradermal delivery of partial...

  2. Estimation of tumour dose enhancement due to gold nanoparticles during typical radiation treatments: a preliminary Monte Carlo study

    International Nuclear Information System (INIS)

    Cho, S H

    2005-01-01

    A recent mice study demonstrated that gold nanoparticles could be safely administered and used to enhance the tumour dose during radiation therapy. The use of gold nanoparticles seems more promising than earlier methods because of the high atomic number of gold and because nanoparticles can more easily penetrate the tumour vasculature. However, to date, possible dose enhancement due to the use of gold nanoparticles has not been well quantified, especially for common radiation treatment situations. Therefore, the current preliminary study estimated this dose enhancement by Monte Carlo calculations for several phantom test cases representing radiation treatments with the following modalities: 140 kVp x-rays, 4 and 6 MV photon beams, and 192 Ir gamma rays. The current study considered three levels of gold concentration within the tumour, two of which are based on the aforementioned mice study, and assumed either no gold or a single gold concentration level outside the tumour. The dose enhancement over the tumour volume considered for the 140 kVp x-ray case can be at least a factor of 2 at an achievable gold concentration of 7 mg Au/g tumour assuming no gold outside the tumour. The tumour dose enhancement for the cases involving the 4 and 6 MV photon beams based on the same assumption ranged from about 1% to 7%, depending on the amount of gold within the tumour and photon beam qualities. For the 192 Ir cases, the dose enhancement within the tumour region ranged from 5% to 31%, depending on radial distance and gold concentration level within the tumour. For the 7 mg Au/g tumour cases, the loading of gold into surrounding normal tissue at 2 mg Au/g resulted in an increase in the normal tissue dose, up to 30%, negligible, and about 2% for the 140 kVp x-rays, 6 MV photon beam, and 192 Ir gamma rays, respectively, while the magnitude of dose enhancement within the tumour was essentially unchanged. (note)

  3. Preliminary analysis of public dose from CFETR gaseous tritium release

    Energy Technology Data Exchange (ETDEWEB)

    Nie, Baojie [Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); University of Science and Technology of China, Hefei, Anhui 230027 (China); Ni, Muyi, E-mail: muyi.ni@fds.org.cn [Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Lian, Chao; Jiang, Jieqiong [Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui 230031 (China)

    2015-02-15

    Highlights: • Present the amounts and limit dose of tritium release to the environment for CFETR. • Perform a preliminary simulation of radiation dose for gaseous tritium release. • Key parameters about soil types, wind speed, stability class, effective release height and age were sensitivity analyzed. • Tritium release amount is recalculated consistently with dose limit in Chinese regulation for CFETR. - Abstract: To demonstrate tritium self-sufficiency and other engineering issues, the scientific conception of Chinese Fusion Engineering Test Reactor (CFETR) has been proposed in China parallel with ITER and before DEMO reactor. Tritium environmental safety for CFETR is an important issue and must be evaluated because of the huge amounts of tritium cycling in reactor. In this work, different tritium release scenarios of CFETR and dose limit regulations in China are introduced. And the public dose is preliminarily analyzed under normal and accidental events. Furthermore, after finishing the sensitivity analysis of key input parameters, the public dose is reevaluated based on extreme parameters. Finally, tritium release amount is recalculated consistently with the dose limit in Chinese regulation for CFETR, which would provide a reference for tritium system design of CFETR.

  4. Phase I study of intraoperative radiotherapy with photon radiosurgery system in children with recurrent brain tumors: Preliminary report of first dose level (10 Gy)

    International Nuclear Information System (INIS)

    Kalapurakal, John A.; Goldman, Stewart; Stellpflug, Wendy; Curran, John; Sathiaseelan, Vythialingam; Marymont, Maryanne H.; Tomita, Tadanori

    2006-01-01

    Purpose: To describe the preliminary results after intraoperative radiotherapy (IORT) with the photon radiosurgery system in children with recurrent brain tumors treated at the first dose level (10 Gy) of a Phase I protocol. Methods and Materials: A Phase I IORT dose escalation protocol was initiated at Children's Memorial Hospital to determine the maximal tolerated IORT dose in children with recurrent brain tumors. Results: Fourteen children have received IORT thus far. Eight had been previously irradiated. Thirteen children had ependymoma. The median follow-up was 16 months. Three patients (21%) developed radiation necrosis on follow-up MRI scans 6 to 12 months after IORT. They had not been previously irradiated and had received 10 Gy to a depth of 5 mm. One required surgery and the other two had resolution of their lesions without treatment. All 3 patients were asymptomatic at the last follow-up. No other late toxicity was observed at the last follow-up visit. Eight patients (57%) had tumor control within the surgical bed after IORT. Conclusion: Our findings have demonstrated the safety and feasibility of IORT to a dose of 10 Gy to 2 mm in children with previously irradiated brain tumors. IORT to a dose of 10 Gy at 5 mm was associated with a greater complication rate

  5. Preliminary characterization of dose in personnel of interventional radiology; Caracterizacao preliminar da dose em profissionais de radiologia intervencionista

    Energy Technology Data Exchange (ETDEWEB)

    Godolfim, Laura Larre; Anes, Mauricio; Bacelar, Alexandre; Lykawka, Rochelle [Hospital de Clinicas de Porto Alegre (HCPA), Porto Alegre, RS (Brazil)

    2016-07-01

    Exposure to X-rays of Interventional Radiology professionals (IR) impacts in the high dose rate received by these individuals, and there are reports of biological effects of this professional activity. Therefore, it is fomented greater control over the doses received by these workers. This research intends to characterize the doses received by the professionals during IR procedures. We evaluated the doses of radiologists, anesthesiologists and nursing staff of the Hospital de Clinicas de Porto Alegre, through measures with dosimeters of the OSL type, distributed in up to six regions of the body of these professionals. Until now were accompanied 33 cholangiography procedures and 29 embolization procedures. As a preliminary result, it was possible to identify a wide variation between doses of the professionals of the same function in each procedure. In overview, the dose of the professionals presented in descending order as a radiologist 1> radiologist 2 > anesthetist > nursing. (author)

  6. A step-up test procedure to find the minimum effective dose.

    Science.gov (United States)

    Wang, Weizhen; Peng, Jianan

    2015-01-01

    It is of great interest to find the minimum effective dose (MED) in dose-response studies. A sequence of decreasing null hypotheses to find the MED is formulated under the assumption of nondecreasing dose response means. A step-up multiple test procedure that controls the familywise error rate (FWER) is constructed based on the maximum likelihood estimators for the monotone normal means. When the MED is equal to one, the proposed test is uniformly more powerful than Hsu and Berger's test (1999). Also, a simulation study shows a substantial power improvement for the proposed test over four competitors. Three R-codes are provided in Supplemental Materials for this article. Go to the publishers online edition of Journal of Biopharmaceutical Statistics to view the files.

  7. Towards understanding household-level forest reliance in Cambodia - study sites, methods, and preliminary findings

    DEFF Research Database (Denmark)

    Ra, Koy; Pichdara, Lonn; Dararath, Yem

    There is growing international interest in the role of forests in poverty prevention and reduction. In consequence, this broad area of investigation has been subject to increased research; one major international research project is that facilitated by the Poverty Environment Network (PEN). This ......). This project covers a large number of sites in 26 countries throughout the tropics. The present report contains contextual details, methodological information and preliminary findings for the PEN sites in Cambodia....

  8. Preliminary estimation of the dose rates of the operation room of the RPR radioisotope cell

    International Nuclear Information System (INIS)

    Rocha, A.C.S.; Silva, J.J.G.; Pina, J.L.S. de; Fajardo, P.W.

    1986-07-01

    During the preliminary studies, about the installations layout of a radioisotope production reactor, the possibility of construction of a radioisotope cell at the reactor building has been investigated. The decisions about that construction has considered mainly the level of the radiation dose over the cell operator. The dose rate has been calculated based on: neutron flux and gamma radiation from fission products and activation materials inside the reactor; volatile fission products such as noble gases and iodides; tritium form ternary fission. The objective was calculate the radiation dose over the cell operator during a journey of 8 hours of work per day. For those calculations some data have been obtained from the Angra-3 reactor. (author)

  9. Automated lung module detection at low-dose CT: preliminary experience

    International Nuclear Information System (INIS)

    Goo, Jin-Mo; Lee, Jeong-Won; Lee, Hyun-Ju; Kim, Seung-Wan; Kim, Jong-Hyo; Im, Jung-Gi

    2003-01-01

    To determine the usefulness of a computer-aided diagnosis (CAD) system for the automated detection of lung nodules at low-dose CT. A CAD system developed for detecting lung nodules was used to process the data provided by 50 consecutive low-dose CT scans. The results of an initial report, a second look review by two chest radiologists, and those obtained by the CAD system were compared, and by reviewing all of these, a gold standard was established. By applying the gold standard, a total of 52 nodules were identified (26 with a diameter ≤ 5 mm; 26 with a diameter > 5 mm). Compared to an initial report, four additional nodules were detected by the CAD system. Three of these, identified only at CAD, formed part of the data used to derive the gold standard. For the detection of nodules > 5 mm in diameter, sensitivity was 77% for the initial report, for the second look review, and 88% for the second look review,and 65% for the CAD system. There were 8.0 ± 5.2 false-positive CAD results per CT study. These preliminary results indicate that a CAD system may improve the detection of pulmonary nodules at low-dose CT

  10. Study of teflon pads as high doses dosemeters

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines; Caldas, Linda V.E.

    2013-01-01

    The aim of this work is to study the Teflon, which is used as a binder in the manufacture of dosimetric tablets, for the feasibility of this material as high dose dosemeter. In this paper we used the technique of thermally stimulated luminescence (OSL) to characterize the dosimetric properties of Teflon. Teflon samples were exposed to different doses of radiation, using a source of gamma radiation ( 60 Co). It was obtained dose-response curve between 100 Gy to 50 kGy and reproducibility of OSL response. The preliminary results show that Teflon is a useful material to high dose dosimetry

  11. Preliminary study of dose equivalent evaluation for residents in radioactivity contaminated rebar buildings

    International Nuclear Information System (INIS)

    Chen, W.L.; Liao, C.C.; Wang, M.T.; Chen, F. D.

    1998-01-01

    It has recently been found that several resident and office buildings in Taiwan were constructed with 60 Co-contaminated reinforcing steel bar (rebar). Both governmental officials and the residents of such buildings have been concerned about this finding. In order to respond to the situation, the government has adopted a number of remedial measures, including full-scale radiation survey, dose evaluation and physical examinations of residents. This article presents three methods for evaluating the dose equivalents of the residents living in the contaminated rebar buildings by means of γ-ray survey, necklace-type thermoluminescence dosimeters (TLDs) and the human lymphocyte chromosome aberration analyses. The results reveal that the dose evaluation by γ-ray survey is rather conservative. Generally for the residents whose annual dose equivalents are greater than 5 mSv (0.5 rem) by γ-ray survey, the dose equivalents from necklace-type TLDs are only within the range of 20 to 50% of the evaluated values mentioned above. For chromosome analyses, at least 500 lymphocyte cells were scored and analyzed for each resident. Most of the chromosome analysis data show that the dose equivalents received by residents are lower than the detection limit of the method (100 mSv) and quite different from the estimated dose obtained from either γ-ray survey or necklace-type TLD measurements

  12. Radical university-industry innovation – research design and preliminary findings from an on-going qualitative case study

    DEFF Research Database (Denmark)

    Gertsen, Frank; Nielsen, René Nesgaard

    and it is arguing that there is a lack of in-depth understanding of such collaborative radical innovation processes. The paper then suggests an abductive research design for an explorative in-depth case study of collaborative radical innovation involving a university and an established Danish manufacturing firm....... Some preliminary findings are presented and briefly discussed, including the role of the university’s formal set-up to deal with IPR/commercialisation and the researchers’ personal networking with industry as well as challenges concerning the sharing of IPR/commercialisation outcomes....

  13. Anticoagulation and high dose liver radiation. A preliminary report

    International Nuclear Information System (INIS)

    Lightdale, C.J.; Wasser, J.; Coleman, M.; Brower, M.; Tefft, M.; Pasmantier, M.

    1979-01-01

    Two groups of patients were observed for evidence of acute radiation hepatitis during high dose radiation to the liver. The first group of 18 patients with metastatic liver disease received an average of 4,050 rad to the whole liver. Half received anticoagulation with warfarin. One patient on anticoagulation developed evidence of acute radiation hepatitis while 2 patients did so without anticoagulation. Eleven patients with Hodgkin's disease received 4,000 rad to the left lobe of the liver during extended field radiation. Four of these 11 patients were anticoagulated to therapeutic range. Only one of the fully anticoagulated patients showed changes on liver scan consistent with radiation hepatitis whereas three did so without anticoagulation. No serious sequelae from anticoagulation occurred in either group. These preliminary data suggest that anticoagulation may be safely administered with high dose hepatic radiation and that further trials with anticoagulation are warranted

  14. Preliminary evaluation of lung doses for dogs exposed to 239PuO2

    International Nuclear Information System (INIS)

    Fisher, D.R.; Cannon, W.C.; Hadley, R.T.; Park, J.F.

    1986-01-01

    A group of beagle dogs exposed to inhaled 239 PuO 2 is being followed for life-span effects. This paper reports preliminary lung dose estimates and dose-response relationships for incidence of lung tumors and radiation pneumonitis which have been observed to date. Doses were estimated by using both conventional dose-averaging and microdosimetric techniques. Cascade impactor sampling data were used to reconstruct the original plutonium aerosol size distributions unique to each of about 120 individual dogs exposed to 239 PuO 2 . Data providing the initial plutonium lung burden and lifetime lung retention-clearance functions of plutonium for each dog were used for calculating average dose rates, cumulative absorbed doses, and specific energy distributions. A linear dose-response relationship for lung tumor induction was estimated on the basis of cumulative lung dose. Average time to death was estimated as a function of average dose rate. Conclusions regarding the potential value of microdosimetry in the interpretation of such dose-response relationships are discussed. 8 refs., 5 figs., 1 tab

  15. 29 CFR 1979.106 - Objections to the findings and the preliminary order and request for a hearing.

    Science.gov (United States)

    2010-07-01

    ... same time to the other parties of record, the OSHA official who issued the findings and order, and the... either the findings or the preliminary order, the findings or preliminary order, as the case may be...

  16. Axitinib in combination with pembrolizumab in patients with advanced renal cell cancer: a non-randomised, open-label, dose-finding, and dose-expansion phase 1b trial.

    Science.gov (United States)

    Atkins, Michael B; Plimack, Elizabeth R; Puzanov, Igor; Fishman, Mayer N; McDermott, David F; Cho, Daniel C; Vaishampayan, Ulka; George, Saby; Olencki, Thomas E; Tarazi, Jamal C; Rosbrook, Brad; Fernandez, Kathrine C; Lechuga, Mariajose; Choueiri, Toni K

    2018-03-01

    Previous studies combining PD-1 checkpoint inhibitors with tyrosine kinase inhibitors of the VEGF pathway have been characterised by excess toxicity, precluding further development. We hypothesised that axitinib, a more selective VEGF inhibitor than others previously tested, could be combined safely with pembrolizumab (anti-PD-1) and yield antitumour activity in patients with treatment-naive advanced renal cell carcinoma. In this ongoing, open-label, phase 1b study, which was done at ten centres in the USA, we enrolled patients aged 18 years or older who had advanced renal cell carcinoma (predominantly clear cell subtype) with their primary tumour resected, and at least one measureable lesion, Eastern Cooperative Oncology Group performance status 0-1, controlled hypertension, and no previous systemic therapy for renal cell carcinoma. Eligible patients received axitinib plus pembrolizumab in a dose-finding phase to estimate the maximum tolerated dose, and additional patients were enrolled into a dose-expansion phase to further establish safety and determine preliminary efficacy. Axitinib 5 mg was administered orally twice per day with pembrolizumab 2 mg/kg given intravenously every 3 weeks. We assessed safety in all patients who received at least one dose of axitinib or pembrolizumab; antitumour activity was assessed in all patients who received study treatment and had an adequate baseline tumour assessment. The primary endpoint was investigator-assessed dose-limiting toxicity during the first two cycles (6 weeks) to estimate the maximum tolerated dose and recommended phase 2 dose. This study is registered with ClinicalTrials.gov, number NCT02133742. Between Sept 23, 2014, and March 25, 2015, we enrolled 11 patients with previously untreated advanced renal cell carcinoma to the dose-finding phase and between June 3, 2015, and Oct 13, 2015, we enrolled 41 patients to the dose-expansion phase. All 52 patients were analysed together. No unexpected toxicities were

  17. A preliminary study on doses of 60Co-γ ray for mutation breeding of Roegneria

    International Nuclear Information System (INIS)

    Jiang Yun; Lin Yang; Xuan Pu; Luo Xiaomei; Zhang Haiqin

    2011-01-01

    Six groups from three species of Roegneria were radiated with eight ladders of 60 Co-γ ray for finding the most suitable absorbed dose. The dose ladders were CK (0 Gy), 50 Gy, 100 Gy, 150 Gy, 200 Gy, 250 Gy, 300 Gy and 400 Gy. The half-lethal dose of six gourps, generated by multi-Target Single Hit Model Equation, were from 59.6 Gy to 172.8 Gy. Germination percentage of seeds, height of seeding, plant survival percentage and setting percentage were investigated. The most suitable absorbed doses of each species primerly were deduced from these data. The research provide a valuable reference for Roegneria mutation breeding on chousing the absorbed does. (authors)

  18. Reaction of the hematopoietic system under long-term emotional stress developed after preliminary gamma-irradiation with low doses

    International Nuclear Information System (INIS)

    Moroz, B.B.; Deshevoj, Yu.B.; Lebedev, V.G.; Lyrshchikova, A.V.; Vorotnikova, T.V.

    1997-01-01

    In experiments on rats and mice it was shown that the preliminary protected gamma-irradiation with cumulative dose of 0.9 Gy (dose rate - 0.03 Gy/day) or single short-term gamma-irradiation with dose of 0.9 Gy (dose rate - 1.61 Gy/min) inhibited development of adaptive reactions and compensatory abilities of the hematopoietic system under long-term emotional stress

  19. Salvage high-dose-rate brachytherapy for local prostate cancer recurrence after radical radiotherapy

    Directory of Open Access Journals (Sweden)

    V. A. Solodkiy

    2016-01-01

    Full Text Available Studies salvage interstitial radiation therapy for recurrent prostate cancer, launched at the end of the XX century. In recent years, more and more attention is paid to high-dose-rate brachytherapy (HDR-BT as a method of treating local recurrence.The purpose of research – preliminary clinical results of salvage high-dose-rate brachytherapy applied in cases of suspected local recurrence or of residual tumour after radiotherapy.Preliminary findings indicate the possibility of using HDR-BT, achieving local tumor control with low genitourinary toxicity.

  20. Preliminary design review report for K Basin Dose Reduction Project

    International Nuclear Information System (INIS)

    Blackburn, L.D.

    1996-01-01

    The strategy for reducing radiation dose, originating from radionuclides absorbed in the K East Basin concrete, is to raise the pool water level to provide additional shielding. This report documents a preliminary design review conducted to ensure that design approaches for cleaning/coating basin walls and modifying other basin components were appropriate. The conclusion of this review was that design documents presently conclusion of this review was that design documents presently completed or in process of modification are and acceptable basis for proceeding to complete the design

  1. A preliminary examination of audience-related communications issues for the Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    Holmes, C.W.

    1991-04-01

    The Hanford Environmental Dose Reconstruction (HEDR) Project will estimate radiation doses people may have received from exposure to radioactive materials released during past operations at the US Department of Energy's (DOE) Hanford Site near Richland, Washington. The HEDR Project was initiated in response to public concerns about possible health impacts from past releases of radioactive materials from Hanford. The TSP recognized early in the project that special mechanisms would be required to effectively communicate to the many different concerned audiences. Accordingly, the TSP directed PNL to examine methods for communicating causes and effects of uncertainties in the dose estimates. After considering the directive and discussing it with the Communications Subcommittee of the TSP, PNL undertook a broad investigation of communications methods to consider for inclusion in the TSP's current communications program. As part of this investigation, a literature review was conducted regarding risk communications. A key finding was that, in order to successfully communicate risk-related information, a thorough understanding of the knowledge level, concerns and information needs of the intended recipients (i.e., the audience) is necessary. Hence, a preliminary audience analysis was conducted as part of the present research. This report summarizes the results of this analysis. 1 ref., 9 tabs.

  2. Preliminary evaluation of second harmonic direct detection scheme for low-dose range in alanine/EPR dosimetry

    International Nuclear Information System (INIS)

    Chen, Felipe; Graeff, Carlos F.O.; Baffa, Oswaldo

    2002-01-01

    The usefulness of a direct detection scheme of the second harmonic (2h) overmodulated signal from irradiated alanine in EPR dosimetry was studied. For this purpose, a group of DL-alanine/paraffin cylindrical pellets was produced. The dosimeters were irradiated with a 60 Co radiotherapy gamma source with doses of 0.05, 0.1, 0.5, 1 and 5 Gy. The EPR measurements were carried out in a VARIAN-E4 spectrometer operating in X-band with optimized parameters to obtain highest amplitude signals of both harmonics. The 2h signal was detected directly at twice the modulation frequency. In preliminary results, the 2h showed some advantages over the 1h such as better resolution for doses below 1 Gy, better repeatability results and better linear behaviour in the dose range indicated. (author)

  3. Cost Finding Principles and Procedures. Preliminary Field Review Edition. Technical Report 26.

    Science.gov (United States)

    Ziemer, Gordon; And Others

    This report is part of the Larger Cost Finding Principles Project designed to develop a uniform set of standards, definitions, and alternative procedures that will use accounting and statistical data to find the full cost of resources utilized in the process of producing institutional outputs. This technical report describes preliminary procedures…

  4. Radiation dose to the patient in radionuclide studies

    International Nuclear Information System (INIS)

    Roedler, H.D.

    1981-01-01

    In medical radionuclide studies, the radiation risk has to be considered in addition to the general risk of administering a pharmaceutical. As radiation exposure is an essential factor in radiation risk estimation, some aspects of internal dose calculation, including radiation risk assessments, are treated. The formalism of current internal dose calculation is presented. The input data, especially the residence time and the absorbed dose per transformation, their origin and accuracy are discussed. Results of internal dose calculations for the ten most frequently used radionuclide studies are presented as somatically effective dose equivalents. The accuracy of internal dose calculation is treated in detail by considering the biokinetics of the radiopharmaceutical, the phantoms used for dose calculations, the absorbed dose per transformation, the administered activity, and the transfer of the dose, calculated for a phantom, to the patient. The internal dose calculated for a reference phantom may be assumed to be in accordance with the actual patient dose within a range described by a factor of about two to three. Finally, risk estimates for nuclear medicine procedures are quantified, being generally of sixth order. The radiation risk from the radioiodine test is comparably higher, but probably lower than calculated according to the UNSCEAR risk coefficients. However, further studies are needed to confirm these preliminary results and to improve the quantification of the radiation risk from the medical use of radionuclides. (author)

  5. Entrances skin dose distribution maps for interventional neuroradiological procedures: A preliminary study

    International Nuclear Information System (INIS)

    Rampado, O.; Ropolo, R.

    2005-01-01

    Does estimation in interventional neuroradiology can be useful to limit skin radiation injuries. The purpose of this study was to evaluate the role of entrance skin dose (ESD) maps in planning exposure condition optimisation. Thirteen cerebral angiography and five embolisation procedures were monitored, measuring ESD, dose-area product (DAP) and other operational parameters. A transmission ionisation chamber, simultaneously measuring air kerma and DAP, measured dose-related quantities. Data acquisition software collected dosimetric and geometrical data during the interventional procedure and provided a distribution map of ESD on a standard phantom digital image, with maximum value estimation. Values of 88-1710 mGy for maximum skin dose and 16.7-343 Gy cm 2 for DAP were found. These data confirm the possibility of deterministic effects during therapeutic interventional neuroradiological procedures like cerebral embolisation. ESD maps are useful to retrospectively study the exposure characteristics of a procedure and plan patient exposure optimisation. (authors)

  6. A preliminary study to find out maximum occlusal bite force in Indian individuals

    DEFF Research Database (Denmark)

    Jain, Veena; Mathur, Vijay Prakash; Pillai, Rajath

    2014-01-01

    PURPOSE: This preliminary hospital based study was designed to measure the mean maximum bite force (MMBF) in healthy Indian individuals. An attempt was made to correlate MMBF with body mass index (BMI) and some of the anthropometric features. METHODOLOGY: A total of 358 healthy subjects in the ag...

  7. Doses in pediatric patients undergoing chest and abdomen CT examinations. Preliminary results

    International Nuclear Information System (INIS)

    Jornada, Tiago S.; Silva, Teogenes A. da

    2011-01-01

    Computed tomography (CT) is a non-invasive method of image production that imparts significant doses to a patient, it is expected that pediatric CT examinations will increase the risk of induced cancer in children. In this study the effective doses in a five year-old child submitted to chest or abdomen CT scans were assessed for comparison purposes. The CTEXPO computed program was used with data from routine protocols of a 0 to 13 year-old children in two public hospitals in Belo Horizonte. Hospital A used a Siemens Dual-Slice unit with 80 kV, 41 mA and pitch 2 for chest or abdomen; hospital B used a Multislice GE unit with 120 kV, 45 mA and pitch 1 for chest and 120 kV, 55 mA. and pitch 1 for abdomen. Results of effective doses in a five year-old child were 1.7 and 1.0 mSv in hospital A and 9.1 and 7.2 mSv in hospital B, for chest and abdomen, respectively. Results were compared to the reference effective doses of 7.2 and 5.0 mSv for chest and abdomen respectively that were derived from the air kerma length product values given in ICRP publication 87. Results of hospital A showed that low dose exposures also can be achieved in CT scans of children. Results showed that even a hospital with a modern facility (hospital B) can provided doses higher than reference values if protocols are not adjusted for children. Preliminary results suggested that there is a room for optimizing children exposure submitted to CT scans. (author)

  8. Growth and profitability in small privately held biotech firms: preliminary findings.

    Science.gov (United States)

    Brännback, Malin; Carsrud, Alan; Renko, Maija; Ostermark, Ralf; Aaltonen, Jaana; Kiviluoto, Niklas

    2009-06-01

    This paper reports on preliminary findings on a study of the relationship of growth and profitability among small privately held Finnish Life Science firms. Previous research results concerning growth and profitability are mixed, ranging from strongly positive to a negative relationship. The conventional wisdom states that growth is a prerequisite for profitability. Our results suggest that the reverse is the case. A high profitability-low growth biotech firm is more probably to make the transition to high profitability-high growth than a firm that starts off with low profitability and high growth.

  9. An open-label, sequential, dose-finding study of peginesatide for the maintenance treatment of anemia in chronic hemodialysis patients

    Directory of Open Access Journals (Sweden)

    Besarab Anatole

    2012-08-01

    Full Text Available Abstract Background Peginesatide is a peptide-based erythropoiesis-stimulating agent that was designed and engineered to stimulate specifically the erythropoietin receptor dimer that governs erythropoiesis. The primary objective of this phase 2 dose-finding study was to determine the once-monthly peginesatide dosing strategy that would maintain hemoglobin within ±1.0 g/dL of baseline values after conversion from epoetin alfa; the safety of peginesatide was evaluated concurrently. Methods Chronic hemodialysis patients on stable regimens of epoetin alfa were sequentially assigned to cohorts that differed on (1 how the peginesatide starting dose was determined (using a single epoetin alfa–to-peginesatide dose conversion ratio or a tiered, weight-based or absolute-dose conversion table and on (2 whether or not a 1-week erythropoiesis-stimulating agent-free interval was used. Peginesatide doses were titrated to maintain hemoglobin levels within ±1.0 g/dL from baseline. Results A total of 164 patients were enrolled and received intravenous peginesatide every 4 weeks for up to 6 doses; the duration of the study including follow-up was ≤29 weeks. Overall, the proportion of patients with hemoglobin levels within ±1.0 g/dL of baseline increased over the course of the study from 39% (Weeks 2–13 to 54% (Weeks 18–25. Cohorts that used tiered dose conversion tables trended towards having more stable peginesatide doses than did those cohorts that used a single dose conversion ratio. Moreover, cohorts that used an erythropoiesis-stimulating agent-free interval did not have the substantial initial increase in hemoglobin levels that was seen in those cohorts that did not use such an interval. In this study, the safety profile of peginesatide was consistent with those of marketed erythropoiesis-stimulating agents. Conclusions The results of this study were used to guide the dosing regimens used subsequently in phase 3 studies. Once

  10. Robust EM Continual Reassessment Method in Oncology Dose Finding

    Science.gov (United States)

    Yuan, Ying; Yin, Guosheng

    2012-01-01

    The continual reassessment method (CRM) is a commonly used dose-finding design for phase I clinical trials. Practical applications of this method have been restricted by two limitations: (1) the requirement that the toxicity outcome needs to be observed shortly after the initiation of the treatment; and (2) the potential sensitivity to the prespecified toxicity probability at each dose. To overcome these limitations, we naturally treat the unobserved toxicity outcomes as missing data, and use the expectation-maximization (EM) algorithm to estimate the dose toxicity probabilities based on the incomplete data to direct dose assignment. To enhance the robustness of the design, we propose prespecifying multiple sets of toxicity probabilities, each set corresponding to an individual CRM model. We carry out these multiple CRMs in parallel, across which model selection and model averaging procedures are used to make more robust inference. We evaluate the operating characteristics of the proposed robust EM-CRM designs through simulation studies and show that the proposed methods satisfactorily resolve both limitations of the CRM. Besides improving the MTD selection percentage, the new designs dramatically shorten the duration of the trial, and are robust to the prespecification of the toxicity probabilities. PMID:22375092

  11. Coordination in contractual relations: Some preliminary findings from the Malaysian housing industry

    Directory of Open Access Journals (Sweden)

    Suraya Ismail

    2008-12-01

    Full Text Available The traditional general procurement route found in many housing projects in Malaysia is conceptualized as a governance structure following the transaction cost economics (TCE approach. This approach has been used to examine governance structures in different economic sectors in several countries but evidence of its use in the context of developing countries is limited. This lack of evidence has prompted the authors to conduct a preliminary study to ascertain whether a TCE approach can explain construction governance structures in developing countries. This research does not discuss the trade-off that governs the choice of hybrids, market or hierarchies for organizing transactions. Rather, it takes advantage of existing research to substantiate the specific properties of hybrid organizations as governance structures. The main focus is coordination. Coordination is specified at two levels. At Level 1 is the coordination of specialization (i.e. the formation of the project team members and at Level 2 is the coordination mode of the contracting parties (client and contractor and the agents involved (the lead designer and project manage r. A case survey method was adopted. Preliminary findings seem to suggest that clients have used hierarchical themes in the contracts and high powered incentives to coordinate with in the contracting parties. The research findings suggest that all participants involved in the sample studied used governance structures symptomatic of a hybrid organization.

  12. Canine-assisted therapy for children with ADHD: preliminary findings from the positive assertive cooperative kids study.

    Science.gov (United States)

    Schuck, Sabrina E B; Emmerson, Natasha A; Fine, Aubrey H; Lakes, Kimberley D

    2015-02-01

    The objective of this study was to provide preliminary findings from an ongoing randomized clinical trial using a canine-assisted intervention (CAI) for 24 children with ADHD. Project Positive Assertive Cooperative Kids (P.A.C.K.) was designed to study a 12-week cognitive-behavioral intervention delivered with or without CAI. Children were randomly assigned to group therapy with or without CAI. Parents of children in both groups simultaneously participated in weekly parent group therapy sessions. Across both treatment groups, parents reported improvements in children's social skills, prosocial behaviors, and problematic behaviors. In both groups, the severity of ADHD symptoms declined during the course of treatment; however, children who received the CAI model exhibited greater reductions in the severity of ADHD symptoms than did children who received cognitive-behavioral therapy without CAI. Results suggest that CAI offers a novel therapeutic strategy that may enhance cognitive-behavioral interventions for children with ADHD. © 2013 SAGE Publications.

  13. Preliminary Calculations of Shutdown Dose Rate for the CTS Diagnostics System

    DEFF Research Database (Denmark)

    Klinkby, Esben Bryndt; Nonbøl, Erik; Lauritzen, Bent

    2015-01-01

    DTU and IST 2 are partners in the design of a collective Thomson Scattering (CTS) diagnostics for ITER through a contract with F4E. The CTS diagnostic utilizes probing radiation of ~60 GHz emitted into the plasma and, using a mirror, collects the scattered radiation by an array of receivers. Having...... on supplying input which affect the system design. Examples include: - Heatloads on plasma facing mirrors and preliminary stress and thermal analysis - Port plug cooling requirements and it's dependence on system design (in particular blanket cut-out) - Shutdown dose-rate calculations (relative analysis...

  14. Preliminary safety assessment study for the conceptual design of a repository in tuff at Yucca Mountain

    International Nuclear Information System (INIS)

    Jackson, J.L.; Gram, H.F.; Hong, K.J.; Ng, H.S.; Pendergrass, A.M.

    1984-12-01

    Preliminary estimates of the upper bounds on postulated worst-case radiological releases resulting from possible accidents during the operating period of a prospective repository in tuff at Yucca Mountain are presented. Possible disrupting events are screened to identify the accidents of greatest potential consequence. The radiological dose commitments for the general public and repository personnel are estimated for postulated releases caused by natural phenomena, man-made events, and operational accidents. All postulated worst-case releases result in doses to the public that are lower than the 0.5-rem, whole-body dose-per-accident limit set by the Nuclear Regulatory Commission (NRC) in 10 CFR 60. Doses to repository personnel are within the NRC's 5.0-rem/yr occupational exposure limit set in 10 CFR 20 for normal operations. Doses are within this limit for all accidents except the transportation accident and fire in a drift. A preliminary risk assessment has also been performed. Based on this preliminary safety study, the proposed site boundaries and design criteria routinely used in constructing nuclear facilities appear to be adequate to protect the safety of the general public during the operating phase of the repository

  15. Durability of treatment response to zolpidem with three different maintenance regimens: a preliminary study.

    Science.gov (United States)

    Perlis, Michael; Grandner, Michael; Zee, Jarcy; Bremer, Erin; Whinnery, Julia; Barilla, Holly; Andalia, Priscilla; Gehrman, Phil; Morales, Knashawn; Thase, Michael; Bootzin, Richard; Ader, Robert

    2015-09-01

    At present, there is no consensus regarding how to medically manage chronic insomnia in the long term. The unstated standard of practice is for patients to use hypnotics intermittently. The present study aimed to compare a partial reinforcement strategy with nightly and intermittent dosing strategies for its potential as a maintenance therapy. A mixed model was used in the study. One between-subjects factor: group (n = 4). One repeated-measures factor: time (12 weekly assessments). A total of 74 subjects with chronic Insomnia were treated with 10 mg zolpidem for 4 weeks. Treatment respondents were randomized to nightly dosing with 10 mg or 5 mg (QHS-10 and QHS-5), intermittent dosing with 10 mg (IDS-10 [3-5 days weekly]), or partial reinforcement dosing with 10 mg (PRS-10 [nightly pill use with 50% active medication and 50% placebos]) for 12 weeks. It was found, in compliant subjects (n = 55), that all four strategies evaluated maintained treatment response over time (ie, prevented or delayed relapse). For the subjects that remained in remission, the subjects in the intermittent dosing group (IDS-10) group exhibited poorer sleep continuity. While best considered a preliminary study, the present findings suggest that the partial reinforcement strategy may be a viable means toward maintaining treatment gains over time with less active medication. Copyright © 2015. Published by Elsevier B.V.

  16. Case study: Findings and lessons learned from investigating a uranium intake and the corresponding dose calculations

    International Nuclear Information System (INIS)

    Beeslaar, Frik; Niekerk, Santie van; Steenkamp, Harry; Visagie, Abrie

    2008-01-01

    Full text: Purpose: To discuss the findings of an investigation into uranium intake and to discuss the lessons learned from the subsequent bioassay monitoring and dose calculations. Method: An investigation was held to determine direct and root causes after elevated air concentration levels were reported during the execution of an ad-hoc task. A programme of bioassay monitoring (urine sampling and lung counts) was implemented for the involved staff and committed effective doses were calculated. Major findings of the investigation: a) Inadequate pre-task assessment led to hazards not being identified and subsequently proper control measures were not implemented; b) Inadequate localised control of contamination led to contamination of worker's clothes and faces and contamination of rest of area; c) Workers were complacent which led to a lapse in safety awareness and subsequently they removed their face masks during the task. Problems experienced with bioassay monitoring and dose calculations: a) Some bioassay samples were not taken or were given incorrectly; b) Calculating doses were difficult due to lack of information regarding date of intake; whether there were other possible intakes; and the physiochemical nature of the uranium; c) Weak correlation between predicted and actual bioassay data; d) Period between starting bioassay monitoring and the actual event was too long. Conclusions: a) Shortcomings in the control of contamination with protective clothing and during the execution of ad-hoc tasks; b) Identifying hazards and assessing it is extremely dependant on the skill and capabilities if the Radiation Protection Officers; c) Instructions to workers regarding sampling of urine and arrangements around the sampling should be very specific with only one person responsible for managing the process; d) Be aware of the psychological impact on the affected workers; e) 2 nd Independent dose calculation important for verifying doses; f) Detection capabilities and

  17. Study on the evaluation of radiation doses in dental radiography. Doses and risks due to dental full mouth examination

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, K [Kanagawa Dental Coll., Yokosuka (Japan)

    1980-09-01

    Radiation doses and possible biological risks due to dental full mouth examination (adult: 10-film technique, child: 6-film technique) were evaluated based on preliminary experiments and statistical surveillance of patients' records. Dosimetrical studies were performed by using head and neck phantoms and a dental x-ray tube. Radiation doses were measured by x-ray films and thermoluminescence dosimeters. For the obtained doses of skin, eyes, thyroid gland and bone marrow, the biological risk of leukemia and thyroid cancer was discussed on the statistical basis of patients at Kanagawa Dental College Hospital. The major findings were as follows: The total number of patients who recieved full mouth x-ray examination at Kanagawa Dental College Hospital in 1978 was 1,099. The number of male patients was 382 (3,804 films) and that of female patients was 717 (7,138 films). In both sexes, the number of patients was the greatest in the group of 8 - 14 years of age. The collective doses of bone marrow due to full mouth 10-film examination performed at Kanagawa Dental College Hospital in 1978 were approximately 6.0 rad, which could induce leukemia with a probability of 1/8,000. The collective doses of thyroid gland were approximately 13 rad, which could induce lethal thyroid cancer with a probability of 1/15,000. The radiation dose due to the dental radiography for examination at Kanagawa Dental College Hospital was proved to be apparently below the level that could actually induce radiation injuries. But the collective radiation doses due to dental examination in Japan as a whole were approximately 8,000 times greater than that in Kanagawa Dental College Hospital.

  18. Preliminary design studies for the DESCARTES and CIDER codes

    International Nuclear Information System (INIS)

    Eslinger, P.W.; Miley, T.B.; Ouderkirk, S.J.; Nichols, W.E.

    1992-12-01

    The Hanford Environmental Dose Reconstruction (HEDR) project is developing several computer codes to model the release and transport of radionuclides into the environment. This preliminary design addresses two of these codes: Dynamic Estimates of Concentrations and Radionuclides in Terrestrial Environments (DESCARTES) and Calculation of Individual Doses from Environmental Radionuclides (CIDER). The DESCARTES code will be used to estimate the concentration of radionuclides in environmental pathways, given the output of the air transport code HATCHET. The CIDER code will use information provided by DESCARTES to estimate the dose received by an individual. This document reports on preliminary design work performed by the code development team to determine if the requirements could be met for Descartes and CIDER. The document contains three major sections: (i) a data flow diagram and discussion for DESCARTES, (ii) a data flow diagram and discussion for CIDER, and (iii) a series of brief statements regarding the design approach required to address each code requirement

  19. Growth hormone response to guanfacine in boys with attention deficit hyperactivity disorder: a preliminary study.

    Science.gov (United States)

    Halperin, Jeffrey M; Newcorn, Jeffrey H; McKay, Kathleen E; Siever, Larry J; Sharma, Vanshdeep

    2003-01-01

    This preliminary study evaluated a method for assessing central noradrenergic function in children via the growth hormone response to a single dose of the alpha-2 adrenergic receptor agonist guanfacine and examined whether this measure distinguishes between attention deficit hyperactivity disorder (ADHD) boys with and without reading disabilities (RD). Plasma growth hormone was assessed before and after the oral administration of guanfacine and placebo in boys with ADHD who were divided into subgroups based on the presence (n = 3) or absence (n = 5) of RD. Guanfacine and placebo conditions did not differ at baseline, but peak growth hormone was significantly higher following guanfacine. The increase in growth hormone following guanfacine was significantly greater in boys without RD as compared to those with RD, with no overlap between the groups. Consistent with findings using peripheral measures of noradrenergic function, these preliminary data suggest that ADHD boys with and without RD may differ in central noradrenergic function.

  20. Dose intercomparison studies for standardization of high-dose dosimetry in Viet Nam

    International Nuclear Information System (INIS)

    Mai Hoang Hoa; Duong Nguyen Dinh; Kojima, T.

    1999-01-01

    The Irradiation Center of the Vietnam Atomic Energy Commission (IC-VAEC) is planning to establish a traceability system for high-dose dosimetry and to provide high-dose standards as a secondary standard dosimetry laboratory (SSDL) level in Vietnam. For countries which do not have a standard dosimetry laboratory, the participation in the International Dose Assurance Service (IDAS) operated by the International Atomic Energy Agency (IAEA) is the most common means to verify own dosimetry performance with a certain uncertainty. This is, however, only one-direction dose intercomparison with evaluation by IAEA including unknown parameter at participant laboratories. The SSDL level laboratory should have traceability as well as compatibility, ability to evaluate uncertainties of its own dosimetry performance by itself In the present paper, we reviewed our dosimetry performance through two-way dose intercomparison studies and self-evaluation of uncertainty in our dosimetry procedure. The performance of silver dichromate dosimeter as reference transfer dosimeter in IC-VAEC was studied through two-way blind dose intercomparison experiments between the IC-VAEC and JAERI. As another channel of dose intercomparison with IAEA, alanine dosimeters issued by IDAS were simultaneously irradiated with the IC-VAEC dichromate dosimeters at IC-VAEC and analyzed by IAEA. Dose intercomparison between IC-VAEC and JAERI results into a good agreement (better than ±2.5%), and IDAS results also show similar agreement within ±3.0%. The uncertainty was self-estimated on the basis of the JAERI alanine dosimetry, and a preliminary value of about 1.86% at a 68% confidence level is established. The results from these intercomparisons and our estimation of the uncertainty are consistent. We hope that our experience is valuable to other countries which do not have dosimetry standard laboratories and/or are planning to establish them. (author)

  1. Retrospective study of sonographic findings in bone involvement associated with rotator cuff calcific tendinopathy: preliminary results of a case series

    Directory of Open Access Journals (Sweden)

    Marcello H. Nogueira-Barbosa

    2015-12-01

    Full Text Available Abstract Objective: The present study was aimed at investigating bone involvement secondary to rotator cuff calcific tendonitis at ultrasonography. Materials and Methods: Retrospective study of a case series. The authors reviewed shoulder ultrasonography reports of 141 patients diagnosed with rotator cuff calcific tendonitis, collected from the computer-based data records of their institution over a four-year period. Imaging findings were retrospectively and consensually analyzed by two experienced musculoskeletal radiologists looking for bone involvement associated with calcific tendonitis. Only the cases confirmed by computed tomography were considered for descriptive analysis. Results: Sonographic findings of calcific tendinopathy with bone involvement were observed in 7/141 (~ 5% patients (mean age, 50.9 years; age range, 42-58 years; 42% female. Cortical bone erosion adjacent to tendon calcification was the most common finding, observed in 7/7 cases. Signs of intraosseous migration were found in 3/7 cases, and subcortical cysts in 2/7 cases. The findings were confirmed by computed tomography. Calcifications associated with bone abnormalities showed no acoustic shadowing at ultrasonography, favoring the hypothesis of resorption phase of the disease. Conclusion: Preliminary results of the present study suggest that ultrasonography can identify bone abnormalities secondary to rotator cuff calcific tendinopathy, particularly the presence of cortical bone erosion.

  2. Development of polygonal surface version of ICRP reference phantoms: Preliminary study for posture change

    International Nuclear Information System (INIS)

    Nguyen, Tat Thang; Yeom, Yeon Soo; Han, Min Cheol; Kim, Chan Hyeong

    2013-01-01

    Even though International Commission on Radiological Protection (ICRP) officially adopted a set of adult male and female voxel phantoms as the ICRP reference phantoms, there are several critical limitations due to the nature of voxel geometry and their low voxel resolutions. In order to overcome these limitations of the ICRP phantoms, we are currently developing polygonal surface version of ICRP reference phantoms by directly converting the ICRP voxel phantoms to polygonal surface geometries. Among the many advantages of the ICRP polygonal surface phantom, especially, it is flexible and deformable. In principle, it is, therefore, possible to make the posture-changed ICRP phantoms which can provide more accurate dose values for exposure situations strongly relevant to worker's postures. As a preliminary study for developing the posture-changed ICRP phantoms, in this work we changed the posture of the preliminary version of ICRP male polygon-surface phantom constructed in the previous study. Organ doses were then compared between original and posture-changed phantoms. In the present study, we successfully changed a posture of the preliminary version of ICRP male polygon-surface phantom to the walking posture. From this results, it was explicitly shown that the polygon-surface version of the ICRP phantoms can be sufficiently modified to be various postures with the posture-changing method used in this study. In addition, it was demonstrated that phantom's posture must be considered in certain exposure situations, which can differ dose values from the conventional standing-posture phantom

  3. Survey of pediatric MDCT radiation dose from university hospitals in Thailand. A preliminary for national dose survey

    Energy Technology Data Exchange (ETDEWEB)

    Kritsaneepaiboon, Supika [Dept. of Radiology, Faculty of Medicine, Prince of Songkla Univ., Hat Yai (Thailand)], e-mail: supikak@yahoo.com; Trinavarat, Panruethai [Dept. of Radiology, Faculty of Medicine, Chulalongkorn Univ., Bangkok (Thailand); Visrutaratna, Pannee [Dept. of Radiology, Faculty of Medicine, Chiang Mai Univ., Chiang Mai (Thailand)

    2012-09-15

    Background: Increasing pediatric CT usage worldwide needs the optimization of CT protocol examination. Although there are previous published dose reference level (DRL) values, the local DRLs should be established to guide for clinical practice and monitor the CT radiation. Purpose: To determine the multidetector CT (MDCT) radiation dose in children in three university hospitals in Thailand in four age groups using the CT dose index (CTDI) and dose length product (DLP). Material and Methods: A retrospective review of CT dosimetry in pediatric patients (<15 years of age) who had undergone head, chest, and abdominal MDCT in three major university hospitals in Thailand was performed. Volume CTDI (CTDIvol) and DLP were recorded, categorized into four age groups: <1 year, 1- < 5 years, 5- <10 years, and 10- <15 years in each scanner. Range, mean, and third quartile values were compared with the national reference dose levels for CT in pediatric patients from the UK and Switzerland according to International Commission on Radiological Protection (ICRP) recommendation. Results: Per age group, the third quartile values for brain, chest, and abdominal CTs were, respectively, in terms of CTDIvol: 25, 30, 40, and 45 mGy; 4.5, 5.7, 10, and 15.6 mGy; 8.5, 9, 14, and 17 mGy; and in terms of DLP: 400, 570, 610, and 800 mGy cm; 80, 140, 305, and 470 mGy cm; and 190, 275, 560,765 mGy cm. Conclusion: This preliminary national dose survey for pediatric CT in Thailand found that the majority of CTDIvol and DLP values in brain, chest, and abdominal CTs were still below the diagnostic reference levels (DRLs) from the UK and Switzerland regarding to ICRP recommendation.

  4. A study on the evaluation of radiation doses in dental radiography

    International Nuclear Information System (INIS)

    Sugimoto, Koju

    1980-01-01

    Radiation doses and possible biological risks due to dental full mouth examination (adult: 10-film technique, child: 6-film technique) were evaluated based on preliminary experiments and statistical surveillance of patients' records. Dosimetrical studies were performed by using head and neck phantoms and a dental x-ray tube. Radiation doses were measured by x-ray films and thermoluminescence dosimeters. For the obtained doses of skin, eyes, thyroid gland and bone marrow, the biological risk of leukemia and thyroid cancer was discussed on the statistical basis of patients at Kanagawa Dental College Hospital. The major findings were as follows: The total number of patients who recieved full mouth x-ray examination at Kanagawa Dental College Hospital in 1978 was 1,099. The number of male patients was 382 (3,804 films) and that of female patients was 717 (7,138 films). In both sexes, the number of patients was the greatest in the group of 8 - 14 years of age. The collective doses of bone marrow due to full mouth 10-film examination performed at Kanagawa Dental College Hospital in 1978 were approximately 6.0 rad, which could induce leukemia with a probability of 1/8,000. The collective doses of thyroid gland were approximately 13 rad, which could induce lethal thyroid cancer with a probability of 1/15,000. The radiation dose due to the dental radiography for examination at Kanagawa Dental College Hospital was proved to be apparently below the level that could actually induce radiation injuries. But the collective radiation doses due to dental examination in Japan as a whole were approximately 8,000 times greater than that in Kanagawa Dental College Hospital. (J.P.N.)

  5. Utility of Social Modeling for Proliferation Assessment - Preliminary Findings

    International Nuclear Information System (INIS)

    Coles, Garill A.; Gastelum, Zoe N.; Brothers, Alan J.; Thompson, Sandra E.

    2009-01-01

    Often the methodologies for assessing proliferation risk are focused around the inherent vulnerability of nuclear energy systems and associated safeguards. For example an accepted approach involves ways to measure the intrinsic and extrinsic barriers to potential proliferation. This paper describes preliminary investigation into non-traditional use of social and cultural information to improve proliferation assessment and advance the approach to assessing nuclear material diversion. Proliferation resistance assessment, safeguard assessments and related studies typically create technical information about the vulnerability of a nuclear energy system to diversion of nuclear material. The purpose of this research project is to find ways to integrate social information with technical information by explicitly considering the role of culture, groups and/or individuals to factors that impact the possibility of proliferation. When final, this work is expected to describe and demonstrate the utility of social science modeling in proliferation and proliferation risk assessments.

  6. Evaluation of Mangosteen juice blend on biomarkers of inflammation in obese subjects: a pilot, dose finding study

    Directory of Open Access Journals (Sweden)

    Singh Betsy B

    2009-10-01

    Full Text Available Abstract Background The ability to reduce inflammation in overweight and obese individuals may be valuable in preventing the progression to metabolic syndrome with associated risks for heart disease and diabetes. The purpose of this study was to evaluate the effect of multiple dosages of a proprietary Mangosteen Juice blend on indicators of inflammation and antioxidant levels in obese patients with elevated C-reactive protein (CRP levels. Methods The study was an 8 week randomized, double-blind, placebo-controlled study with a pre-study 2 week washout period. The study included four groups including placebo and three difference doses of the test product, XanGo Juice™: 3, 6 or 9 oz twice daily. The primary outcome measure of this study was high-sensitivity (HS-CRP. Secondary outcome measures included other biochemical indicators of inflammation, anthropomorphic measures and a safety evaluation. Results One hundred twenty two (122 persons were screened for the study, 44 were randomized and 40 completed the study. HS-CRP measurements dropped after 8 weeks treatment compared to baseline in all 3 dose groups and increased in the placebo group. The changes from baseline were not significant but the comparison of change from baseline was significant for the 18 oz group when compared to placebo (p = 0.02. Other markers of inflammation (inflammatory cytokines and a marker for lipid peroxidation (F2 isoprostane did not show any significant differences when compared with placebo. There was a trend towards a decrease in BMI in the juice groups. There were no side effects reported in any of the groups and none of the laboratory or EKG safety assessments indicated clinically significant changes for any subject. Conclusion In this pilot, dose-finding study, a proprietary mangosteen juice blend (XanGo Juice™ reduced CRP levels (increased change from baseline compared to placebo for those taking the highest dose of 18 oz per day. Further studies with a

  7. Evaluation of Mangosteen juice blend on biomarkers of inflammation in obese subjects: a pilot, dose finding study.

    Science.gov (United States)

    Udani, Jay K; Singh, Betsy B; Barrett, Marilyn L; Singh, Vijay J

    2009-10-20

    The ability to reduce inflammation in overweight and obese individuals may be valuable in preventing the progression to metabolic syndrome with associated risks for heart disease and diabetes. The purpose of this study was to evaluate the effect of multiple dosages of a proprietary Mangosteen Juice blend on indicators of inflammation and antioxidant levels in obese patients with elevated C-reactive protein (CRP) levels. The study was an 8 week randomized, double-blind, placebo-controlled study with a pre-study 2 week washout period. The study included four groups including placebo and three difference doses of the test product, XanGo Juice: 3, 6 or 9 oz twice daily. The primary outcome measure of this study was high-sensitivity (HS)-CRP. Secondary outcome measures included other biochemical indicators of inflammation, anthropomorphic measures and a safety evaluation. One hundred twenty two (122) persons were screened for the study, 44 were randomized and 40 completed the study. HS-CRP measurements dropped after 8 weeks treatment compared to baseline in all 3 dose groups and increased in the placebo group. The changes from baseline were not significant but the comparison of change from baseline was significant for the 18 oz group when compared to placebo (p = 0.02). Other markers of inflammation (inflammatory cytokines) and a marker for lipid peroxidation (F2 isoprostane) did not show any significant differences when compared with placebo. There was a trend towards a decrease in BMI in the juice groups. There were no side effects reported in any of the groups and none of the laboratory or EKG safety assessments indicated clinically significant changes for any subject. In this pilot, dose-finding study, a proprietary mangosteen juice blend (XanGo Juice) reduced CRP levels (increased change from baseline) compared to placebo for those taking the highest dose of 18 oz per day. Further studies with a larger population are required to confirm and further define the

  8. BAYESIAN DATA AUGMENTATION DOSE FINDING WITH CONTINUAL REASSESSMENT METHOD AND DELAYED TOXICITY

    Science.gov (United States)

    Liu, Suyu; Yin, Guosheng; Yuan, Ying

    2014-01-01

    A major practical impediment when implementing adaptive dose-finding designs is that the toxicity outcome used by the decision rules may not be observed shortly after the initiation of the treatment. To address this issue, we propose the data augmentation continual re-assessment method (DA-CRM) for dose finding. By naturally treating the unobserved toxicities as missing data, we show that such missing data are nonignorable in the sense that the missingness depends on the unobserved outcomes. The Bayesian data augmentation approach is used to sample both the missing data and model parameters from their posterior full conditional distributions. We evaluate the performance of the DA-CRM through extensive simulation studies, and also compare it with other existing methods. The results show that the proposed design satisfactorily resolves the issues related to late-onset toxicities and possesses desirable operating characteristics: treating patients more safely, and also selecting the maximum tolerated dose with a higher probability. The new DA-CRM is illustrated with two phase I cancer clinical trials. PMID:24707327

  9. Poster - 56: Preliminary comparison of FF- and FFF-VMAT for prostate plans with higher rectal dose

    International Nuclear Information System (INIS)

    Liu, Baochang; Darko, Johnson; Osei, Ernest

    2016-01-01

    Purpose: A recent retrospective study found 53 patients previously treated to 78Gy/39 using flattened filtered (FF) 6X-VMAT at GRRCC had rectal DVH more than one standard deviation higher than the average. This study was to investigate if using 6FFFor10FFF beams could reduce these DVHs without compromising target coverage. Methods: Twenty patients’ plans were re-planed with 2-arc 6X-VMAT, 6FFF-VMAT and 10FFF-VMAT using the Eclipse TPS following departmental protocol. All plans had the same optimization and normalization, and were evaluated against the acceptance criteria from the QUANTEC and Emami. Statistical differences in the mean dose to OARs (D m ) and PTV homogeneity index (HI) between energies were tested using the paired sample Wilcoxon signed rank statistical method (p<0.05). Beam delivery accuracy was checked on five patients using portal dosimetry (PD). Results: The PTV HI for the 10FFF shows no statistical difference from the 6X. All the OARs, except left femoral head with 6FFF, have significantly lower Dm using 6FFF and 10FFF .There is no difference in the maximum doses to rectum and bladder and are limited by the prescribed doses. Measurements show good agreements in the gamma evaluation (3%/3mm) for all energies. Conclusion: This preliminary study shows that doses to the OARs are reduced using 10FFF for the same target coverage. The plans using 6FFF result in lower doses to some OARs, and statistically different PTV HI. All plans showed very good agreement with measurements.

  10. Poster - 56: Preliminary comparison of FF- and FFF-VMAT for prostate plans with higher rectal dose

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Baochang; Darko, Johnson; Osei, Ernest [Grand River Regional Cancer Centre, Kitchener, Ontario (Canada)

    2016-08-15

    Purpose: A recent retrospective study found 53 patients previously treated to 78Gy/39 using flattened filtered (FF) 6X-VMAT at GRRCC had rectal DVH more than one standard deviation higher than the average. This study was to investigate if using 6FFFor10FFF beams could reduce these DVHs without compromising target coverage. Methods: Twenty patients’ plans were re-planed with 2-arc 6X-VMAT, 6FFF-VMAT and 10FFF-VMAT using the Eclipse TPS following departmental protocol. All plans had the same optimization and normalization, and were evaluated against the acceptance criteria from the QUANTEC and Emami. Statistical differences in the mean dose to OARs (D{sub m}) and PTV homogeneity index (HI) between energies were tested using the paired sample Wilcoxon signed rank statistical method (p<0.05). Beam delivery accuracy was checked on five patients using portal dosimetry (PD). Results: The PTV HI for the 10FFF shows no statistical difference from the 6X. All the OARs, except left femoral head with 6FFF, have significantly lower Dm using 6FFF and 10FFF .There is no difference in the maximum doses to rectum and bladder and are limited by the prescribed doses. Measurements show good agreements in the gamma evaluation (3%/3mm) for all energies. Conclusion: This preliminary study shows that doses to the OARs are reduced using 10FFF for the same target coverage. The plans using 6FFF result in lower doses to some OARs, and statistically different PTV HI. All plans showed very good agreement with measurements.

  11. Preliminary results of measurement of natural environmental radiation levels and doses to population in China

    International Nuclear Information System (INIS)

    Wang Qiliang; He Miaoting; Shu Qi

    1985-01-01

    In this paper the preliminary results of measurement of natural environmental radiation levels in China with RSS-111 high pressure ionization chamber and estimated doses to population are reported. A total of 2,723 indoor locales throughout China were measured. The results showed that the average absorbed dose rates in air due to gamma radiation for indoors and outdoors were 11.0 x 10 -8 Gy.h -1 and 7.4 x 10 -8 Gy.h -1 , respectively, and those due to cosmic rays were 3.2 x 10 -8 Gy.h -1 and 3.7 x 10 -8 Gy.h -1 , respectively. The annual average effective dose equivalent to population was 919 μSv, including 630 μSv from natural gamma radiation and 289 μSv from cosmic rays

  12. Preliminary report. Preliminary findings and views concerning the exemption of kerojet fuels from the Mandatory Petroleum Allocation and Price Regulations

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-01-01

    Preliminary findings indicate the following: kerojet fuel is not in short supply; it will not adversely impact on the supply of other petroleum products subject to the Emergency Petroleum Allocation Act; competition and market forces are adequate; and it will not result in inequitable prices for kerojet or other products. Chapter II provides background information on the use, production, and distribution of kerojet. Chapter III analyzes the historical interaction of supply, demand, and price, and explores the market structure for kerojet during 1968 to 1976, prior to and during imposition of allocation and price controls. Chapter IV examines the effect upon kerojet supply, demand, price, and market structure of exempting kerojet from controls and indicates the benefits to be derived from such exemption. In Chapter V, the potential economic impacts of exemption are evaluated. Chapter VI provides a final summary of the DOE's findings and views in support of its preliminary judgment that kerojet should be exempted from allocation and price regulations. (MCW)

  13. Landscape ecological impact of climatic change some preliminary findings of the LICC Project

    International Nuclear Information System (INIS)

    Boer, M.M.

    1991-01-01

    The main objectives of the LICC project are to address the potential effects of a future climatic change on (semi-) natural terrestrial ecosystems and landscapes in Europe; six case studies are covered: alpine regions, boreal and subartic regions, Mediterranean region, fluvial systems, wetlands and coastal dunes. Preliminary findings showed a serious lack in fundamental ecological knowledge. Assessment of potential effects involved changes in water and sediment fluxes, changes in the vegetation cover, species response, dispersal and migration in a fragmented landscape and modification of climate impacts by man

  14. Prevalence of incidental or unexpected findings on low-dose CT performed during routine SPECT/CT nuclear medicine studies

    International Nuclear Information System (INIS)

    Yap, Kelvin Kwok-Ho; Sutherland, Tom; Shafik-Eid, Raymond; Taubman, Kim; Schlicht, Stephen; Ramaseshan, Ganeshan

    2015-01-01

    In nuclear medicine, single-photon-emission computed tomography (SPECT) is often combined with ‘simultaneous’ low-dose CT (LDCT) to provide complementary anatomical and functional correlation. As a consequence, numerous incidental and unexpected findings may be detected on LDCT. Recognition of these findings and appropriate determination of their relevance can add to the utility of SPECT/CT. We aimed to evaluate the prevalence and categorise the relevance of incidental and unexpected findings on LDCT scans performed as part of routine SPECT/CT studies. All available LDCT scans performed as part of SPECT/CT studies at St. Vincent's Hospital Melbourne in the year 2013 were retrospectively reviewed. Two qualified radiologists independently reviewed the studies and any previous available imaging and categorised any detected incidental findings. A total of 2447 LDCT studies were reviewed. The relevance of the findings was classified according to a modified version of a scale used in the Colonography Reporting and Data System: E1 = normal or normal variant (28.0%); E2 = clinically unimportant (63.5%); E3 = likely unimportant or incompletely characterised (6.2%); E4 = potentially important (2.5%). Imaging specialists need to be cognisant of incidental and unexpected findings present on LDCT studies performed as part of SPECT/CT. Appropriate categorisation of findings and communication of potentially important findings to referring clinicians should form part of routine practice. The overall prevalence of potentially significant incidental and unexpected findings in our series was 8.7% (E3, 6.2%; E4, 2.5%) and was comparable to rates in other published imaging series.

  15. Dose-finding study of carbamylated monomeric allergoid tablets in grass-allergic rhinoconjunctivitis patients.

    Science.gov (United States)

    Mösges, Ralph; Rohdenburg, Christina; Eichel, Andrea; Zadoyan, Gregor; Kasche, Elena-Manja; Shah-Hosseini, Kija; Lehmacher, Walter; Schmalz, Petra; Compalati, Enrico

    2017-11-01

    To determine the optimal effective and safe dose of sublingual immunotherapy tablets containing carbamylated monomeric allergoids in patients with grass pollen-induced allergic rhinoconjunctivitis. In this prospective, randomized, double-blind, active-controlled, multicenter, Phase II study, four different daily doses were applied preseasonally for 12 weeks. Of 158 randomized adults, 155 subjects (safety population) received 300 units of allergy (UA)/day (n = 36), 600 UA/day (n = 43), 1000 UA/day (n = 39), or 2000 UA/day (n = 37). After treatment, 54.3, 47.6, 59.0 and 51.4% of patients, respectively, ceased to react to the highest allergen concentration in a conjunctival provocation test. Furthermore, the response threshold improved in 70.4, 62.9, 76.7 and 66.7% of patients, respectively. No serious adverse events occurred. This study found 1000 UA/day to be the optimal effective and safe dose.

  16. SU-E-T-632: Preliminary Study On Treating Nose Skin Using Energy and Intensity Modulated Electron Beams with Monte Carlo Based Dose Calculations

    International Nuclear Information System (INIS)

    Jin, L; Eldib, A; Li, J; Price, R; Ma, C

    2015-01-01

    Purpose: Uneven nose surfaces and air cavities underneath and the use of bolus present complexity and dose uncertainty when using a single electron energy beam to plan treatments of nose skin with a pencil beam-based planning system. This work demonstrates more accurate dose calculation and more optimal planning using energy and intensity modulated electron radiotherapy (MERT) delivered with a pMLC. Methods: An in-house developed Monte Carlo (MC)-based dose calculation/optimization planning system was employed for treatment planning. Phase space data (6, 9, 12 and 15 MeV) were used as an input source for MC dose calculations for the linac. To reduce the scatter-caused penumbra, a short SSD (61 cm) was used. Our previous work demonstrates good agreement in percentage depth dose and off-axis dose between calculations and film measurement for various field sizes. A MERT plan was generated for treating the nose skin using a patient geometry and a dose volume histogram (DVH) was obtained. The work also shows the comparison of 2D dose distributions between a clinically used conventional single electron energy plan and the MERT plan. Results: The MERT plan resulted in improved target dose coverage as compared to the conventional plan, which demonstrated a target dose deficit at the field edge. The conventional plan showed higher dose normal tissue irradiation underneath the nose skin while the MERT plan resulted in improved conformity and thus reduces normal tissue dose. Conclusion: This preliminary work illustrates that MC-based MERT planning is a promising technique in treating nose skin, not only providing more accurate dose calculation, but also offering an improved target dose coverage and conformity. In addition, this technique may eliminate the necessity of bolus, which often produces dose delivery uncertainty due to the air gaps that may exist between the bolus and skin

  17. Treating Substance-Using Women and Their Children in Public Housing: Preliminary Evaluation Findings.

    Science.gov (United States)

    Metsch, Lisa R.; Wolfe, Harlan P.; Fewell, Rebecca; McCoy, Clyde B.; Elwood, William N.; Wohler-Torres, Brad; Petersen-Baston, Pamela; Haskins, Henry V.

    2001-01-01

    SafePort is a residential substance abuse treatment program within public housing to provide drug treatment to parenting women in Key West, Florida. All family members--women, children, and significant others--receive comprehensive assessments to determine appropriate therapeutic interventions. Preliminary evaluation findings suggest that women…

  18. Cytogenetics dosimetry: dose-response curve for low doses of X-ray

    International Nuclear Information System (INIS)

    Lara, Virginia E. Noval; Pineda Bolivar, William R.; Riano, Victor M. Pabon; Ureana, Cecilia Crane

    2013-01-01

    The purpose of this study was to conduct a preliminary study for the standardization in the future, the dose-response curve for low doses of X-rays, through the analysis of in vitro cultures of peripheral blood samples of 3 men and 3 women occupationally not exposed to artificial sources of ionizing radiation, age 18-40 years, where possible nonsmokers

  19. Relationship Dissolution and Psychologically Aggressive Dating Relationships: Preliminary Findings From a College-Based Relationship Education Course.

    Science.gov (United States)

    Negash, Sesen; Cravens, Jaclyn D; Brown, Preston C; Fincham, Frank D

    This study evaluated the impact of a relationship education program, delivered as part of a college course, among students (N = 152) who reported experiencing psychological aggression in their exclusive dating relationship. Preliminary results showed that compared to those in the control group, participants receiving relationship education were significantly more likely to end their romantic relationship, even after controlling for relationship satisfaction. Furthermore, when relationship termination occurred, those in the intervention group were significantly more likely to attribute the breakup to their participation in the class as compared to those in the control group. The tentative findings are an important preliminary step in assessing the benefits of relationship education in reducing the risk of psychological aggression among college students.

  20. Parents and Teachers‘ Voices of Quality Preschool: Preliminary findings from Indonesia

    Directory of Open Access Journals (Sweden)

    Edi Waluyo

    2015-11-01

    Full Text Available This paper describes preliminary findings of a study on Indonesian teachers and parents’ perspectives of quality preschool program. It departs in one hand from the context of the Indonesian government massive promotion of early childhood programs and on the other hand of the country top-down, government-dominated quality system. Moreover, it is contextualized within the growing body of literatures, which emphasizes the centrality of quality issues to early childhood service and the notion that quality is a complex, contextual, multifaceted construction and idea. This study found that even though parents and teachers’ constructions of quality share some commonalities with those of the government-constructed ones, they significantly differ. The government-constructed quality framework for example emphasizes on teacher formal qualification, but teachers and parents have moved beyond such formality and urged the importance of teacher personal character

  1. A 12-week DBPC dose-finding study with sublingual monomeric allergoid tablets in house dust mite-allergic patients.

    Science.gov (United States)

    Hüser, C; Dieterich, P; Singh, J; Shah-Hosseini, K; Allekotte, S; Lehmacher, W; Compalati, E; Mösges, R

    2017-01-01

    In sublingual immunotherapy, optimal doses are a key factor for therapeutic outcomes. The aim of this study with tablets containing carbamylated monomeric house dust mite allergoids was to determine the most effective and safe dose. In this double-blind, placebo-controlled dose-finding study, 131 patients with house dust mite-induced allergic rhinoconjunctivitis were randomized to 12-week treatments with 300 UA/day, 1000 UA/day, 2000 UA/day, 3000 UA/day or placebo. Conjunctival provocation tests (CPT) were performed before, during and after treatment. The change in mean allergic severity (primary endpoint), calculated from the severity of the CPT reaction, and the proportion of patients with an improved CPT threshold (secondary endpoint) determined the treatment effect. The mean allergic severity decreased in all groups, including the placebo group. It was lower in all active treatment groups (300 UA/day: 0.14, 1000 UA/day: 0.15, 2000 UA/day: 0.10, 3000 UA/day: 0.15) than in the placebo group (0.30). However, this difference was not statistically significant (P allergoid sublingual tablets is well tolerated and reduces the CPT reaction in house dust mite-allergic patients. © 2016 The Authors. Allergy Published by John Wiley & Sons Ltd.

  2. Modern dose-finding designs for cancer phase I trials drug combinations and molecularly targeted agents

    CERN Document Server

    Hirakawa, Akihiro; Daimon, Takashi; Matsui, Shigeyuki

    2018-01-01

    This book deals with advanced methods for adaptive phase I dose-finding clinical trials for combination of two agents and molecularly targeted agents (MTAs) in oncology. It provides not only methodological aspects of the dose-finding methods, but also software implementations and practical considerations in applying these complex methods to real cancer clinical trials. Thus, the book aims to furnish researchers in biostatistics and statistical science with a good summary of recent developments of adaptive dose-finding methods as well as providing practitioners in biostatistics and clinical investigators with advanced materials for designing, conducting, monitoring, and analyzing adaptive dose-finding trials. The topics in the book are mainly related to cancer clinical trials, but many of those topics are potentially applicable or can be extended to trials for other diseases. The focus is mainly on model-based dose-finding methods for two kinds of phase I trials. One is clinical trials with combinations of tw...

  3. Phase I dose-finding study of cabazitaxel administered weekly in patients with advanced solid tumours

    International Nuclear Information System (INIS)

    Fumoleau, Pierre; Trigo, Jose Manuel; Isambert, Nicolas; Sémiond, Dorothée; Gupta, Sunil; Campone, Mario

    2013-01-01

    Cabazitaxel is approved in patients with metastatic hormone-refractory prostate cancer previously treated with a docetaxel-containing regimen. This study evaluated a weekly cabazitaxel dosing regimen. Primary objectives were to report dose-limiting toxicities (DLTs) and to determine the maximum tolerated dose (MTD). Efficacy, safety and pharmacokinetics were secondary objectives. Cabazitaxel was administered weekly (1-hour intravenous infusion at 1.5–12 mg/m2 doses) for the first 4 weeks of a 5-week cycle in patients with solid tumours. Monitoring of DLTs was used to determine the MTD and the recommended weekly dose. Thirty-one patients were enrolled. Two of six patients experienced DLTs at 12 mg/m 2 , which was declared the MTD. Gastrointestinal disorders were the most common adverse event. Eight patients developed neutropenia (three ≥ Grade 3); one occurrence of febrile neutropenia was reported. There were two partial responses (in breast cancer) and 13 patients had stable disease (median duration of 3.3 months). Increases in C max and AUC 0–t were dose proportional for the 6–12 mg/m 2 doses. The MTD of weekly cabazitaxel was 12 mg/m 2 and the recommended weekly dose was 10 mg/m 2 . The observed safety profile and antitumour activity of cabazitaxel were consistent with those observed with other taxanes in similar dosing regimens. The study was registered with ClinicalTrials.gov as http://www.clinicaltrials.gov/ct2/show/NCT01755390

  4. A Cs-137 afterloading device. Preliminary results of cell kinetic effects of low dose-rate irradiation in an experimental tumour

    International Nuclear Information System (INIS)

    Rutgers, D.H.

    1988-01-01

    A Cs-137 afterloading technique is described which can be used in experimental tumours. Preliminary results, obtained with the human cervical carcinoma ME-180 xenografted to nude athymic mice, demonstrated that 20 Gy of low dose-rate irradiation induced an important redistribution of cells over cell cycle. The proportion of cells in G2-phase increased from 14.4% to 44.2% at 140 hours after irradiation. This method allows an accurate calculation of the dose-rate distribution in the tumour. Investigations of the cell kinetic effects of low dose-rate irradiation, at different dose-rates and different total doses, are therefore facilitated by the technique. (orig.) [de

  5. Preliminary study of image findings of femoroacetabular impingement

    International Nuclear Information System (INIS)

    Guo Zhe; Zhang Jing; Hong Nan; Cheng Xiaoguang

    2010-01-01

    Objective: To assess the image findings of femoroacetabular impingement (FAI). Methods: Image findings of 9 patients with surgically proved femoroacetabular impingement were retrospectively reviewed for characteristic image findings of FAI. All 9 patients underwent X-ray examinations and MRI of affected hip, and 1 patient underwent MR arthrography (MRA) additionally. Results: X-ray examinations of all 9 patients showed bump at femoral head-neck junction or overcoverage of the acetabular. MRI showed various degrees of injury of anterosuperior labrum in all 9 patients. The injuries were stage Ⅰ A in 2 cases, stage Ⅰ B in 3, stage Ⅱ A in 2, and stage Ⅱ B in 2. MRA of the case showed tears of anterosuperior labrum, with contrast media entering into the teared labrum. There were sclerosis and cystic degeneration of subchondral bone of femoral head in 2 cases, and these findings were confirmed as cartilage delamination by surgery. Conclusions: MRI can display the injures of labrum and articular cartilage, which is helpful to the early diagnosis of' FAI. (authors)

  6. Preliminary estimation of minimum target dose in intracavitary radiotherapy for cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ohara, Kiyoshi; Oishi-Tanaka, Yumiko; Sugahara, Shinji; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    2001-08-01

    In intracavitary radiotherapy (ICRT) for cervical cancer, minimum target dose (D{sub min}) will pertain to local disease control more directly than will reference point A dose (D{sub A}). However, ICRT has been performed traditionally without specifying D{sub min} since the target volume was not identified. We have estimated D{sub min} retrospectively by identifying tumors using magnetic resonance (MR) images. Pre- and posttreatment MR images of 31 patients treated with high-dose-rate ICRT were used. ICRT was performed once weekly at 6.0 Gy D{sub A}, and involved 2-5 insertions for each patient, 119 insertions in total. D{sub min} was calculated arbitrarily simply at the point A level using the tumor width (W{sub A}) to compare with D{sub A}. W{sub A} at each insertion was estimated by regression analysis with pre- and posttreatment W{sub A}. D{sub min} for each insertion varied from 3.0 to 46.0 Gy, a 16-fold difference. The ratio of total D{sub min} to total D{sub A} for each patient varied from 0.5 to 6.5. Intrapatient D{sub min} difference between the initial insertion and final insertion varied from 1.1 to 3.4. Preliminary estimation revealed that D{sub min} varies widely under generic dose prescription. Thorough D{sub min} specification will be realized when ICRT-applicator insertion is performed under MR imaging. (author)

  7. Preliminary report. Preliminary findings and views concerning the exemption of aviation gasoline from the Mandatory Petroleum Allocation and Price Regulations

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-01-01

    Preliminary findings indicate that: the fuel is not in short supply; exemption will not have an adverse impact on supply of any other petroleum product subject to the Emergency Petroleum allocation Act of 1973; competition and market force are adequate; exemption will not result in inequitable prices; and exemption will not have adverse state or regional impacts or any other adverse impacts. Chapter II provides background information on the use, production, and distribution of aviation gasoline. Chapter III analyzes the historical interaction of supply, demand, and price, and explores the market structure for aviation gasoline during 1968 to 1976, prior to and during imposition of allocation and price controls. Chapter IV examines aviation gasoline supply, demand, price, and market structure impacts of exempting aviation gasoline from controls. In Chapter V, the potential economic impacts of exemption are evaluated. Chapter VI provides a final summary of the DOE's findings and views in support of its preliminary judgment that aviation gasoline should be exempted from allocation and price regulations. (MCW)

  8. Extremity exposure in nuclear medicine: Preliminary results of a European study

    International Nuclear Information System (INIS)

    Merce, M. S.; Ruiz, N.; Barth, I.; Carnicer, A.; Donadille, L.; Ferrari, P.; Fulop, M.; Ginjaume, M.; Gualdrini, G.; Krim, S.; Mariotti, F.; Ortega, X.; Rimpler, A.; Vanhavere, F.; Baechler, S.

    2011-01-01

    The Work Package 4 of the ORAMED project, a collaborative project (2008-11) supported by the European Commission within its seventh Framework Programme, is concerned with the optimisation of the extremity dosimetry of medical staff in nuclear medicine. To evaluate the extremity doses and dose distributions across the hands of medical staff working in nuclear medicine departments, an extensive measurement programme has been started in 32 nuclear medicine departments in Europe. This was done using a standard protocol recording all relevant information for radiation exposure, i.e. radiation protection devices and tools. This study shows the preliminary results obtained for this measurement campaign. For diagnostic purposes, the two most-used radionuclides were considered: 99m Tc) and 18 F. For therapeutic treatments, Zevalin R and DOTATOC (both labelled with 90 Y) were chosen. Large variations of doses were observed across the hands depending on different parameters. Furthermore, this study highlights the importance of the positioning of the extremity dosemeter for a correct estimate of the maximum skin doses. (authors)

  9. Cognitive remediation therapy for patients with anorexia nervosa: preliminary findings

    Directory of Open Access Journals (Sweden)

    Campbell Iain C

    2007-06-01

    Full Text Available Abstract Background Anorexia nervosa (AN is a severe mental illness. Drug treatments are not effective and there is no established first choice psychological treatment for adults with AN. Neuropsychological studies have shown that patients with AN have difficulties in cognitive flexibility: these laboratory based findings have been used to develop a clinical intervention based on Cognitive Remediation Therapy (CRT which aims to use cognitive exercises to strengthen thinking skills. Aims 1 To conduct a preliminary investigation of CRT in patients with AN 2 to explore whether cognitive training improves performance in set shifting tasks 3 to explore whether CRT exercises are appropriate and acceptable to AN patients 4 to use the data to improve a CRT module for AN patients. Methods Intervention was comprised of ten 45 minute sessions of CRT. Four patients with AN were assessed before and after the ten sessions using five set shifting tests and clinical assessments. At the end, each patient wrote a letter providing feedback on the intervention. Results Post intervention, three of the five set shifting assessments showed a moderate to large effect size in performance and two showed a large effect size in performance, both indicative of improved flexibility. Patients were aware of an improvement in their cognitive flexibility qualitative feedback was generally positive towards CRT. Discussion This preliminary study suggests that CRT changed performance on flexibility tasks and may be beneficial for acute, treatment resistant patients with AN. Feedback gathered from this small case series has enabled modification of the intervention for a future larger study, for example, by linking exercises with real life behavioural tasks and including exercises that encourage global thinking. Conclusion This exploratory study has produced encouraging data supporting the use of CRT in patients with AN: it has also provided insight into how the module should be

  10. Reducing dose in paediatric CT: a preliminary study of radiographers' knowledge

    International Nuclear Information System (INIS)

    Heagney, J.; Lewis, S.; Chaffey, C.; Howlett, G.; Moran, A.; McLean, D.

    2003-01-01

    The objective of this study is to evaluate the responses of Australian radiographers in comparison with current literature on paediatric protocols and scanning recommendations in order to determine how and if paediatric Computed Tomography (CT) exposure reductions are taking place within Medical Imaging Departments. Subjects and Methods: The method involved a dual format; consisting of surveying 30 CT radiographers, and additionally, interviewing 5 senior CT radiographers. Of the 30 surveys completed, one was completed by a PDY radiographer, 7 by CT Senior radiographers and 22 by CT radiographers. The survey contained a range of questions about appropriate paediatric CT scanning parameters and protocols. Five CT Seniors were interviewed to ascertain the current level and opinion of training in paediatric protocols, in-house educational programs and the implementation of radiation dose saving parameters. Radiographers demonstrated reasonable ability to identify suitable paediatric protocols and believed the in-house CT protocols resident to their medical imaging department to be adequate, despite many utilising exposures higher than those from recommended literature. The interviews revealed that no further training in CT paediatric dose reduction was currently available, however survey responses indicated that further training would be beneficial. This study demonstrates that radiographers are aware of the need to reduce exposure parameters for paediatric CT and tend to follow protocols in place within their workplace, regardless of suitability and patient needs. Copyright (2003) Australian Institute of Radiography

  11. Reducing dose in paediatric CT: a preliminary study of radiographers' Knowledge

    International Nuclear Information System (INIS)

    Heagney, Jillian; Lewis, Sarah; Chaffey, Clare; Howlett, Genevieve; Moran, Alexander; McLean, Donald

    2003-01-01

    The objective of this study is to evaluate the responses of Australian radiographers in comparison with current literature on paediatric protocols and scanning recommendations in order to determine how and if paediatric Computed Tomography (CT) exposure reductions are taking place within Medical Imaging Departments. Subjects and Methods: The method involved a dual format; consisting of surveying 30 CT radiographers, and additionally, interviewing 5 senior CT radiographers. Of the 30 surveys completed, one was completed by a PDY radiographer, 7 by CT Senior radiographers and 22 by CT radiographers. The survey contained a range of questions about appropriate paediatric CT scanning parameters and protocols. Five CT Seniors were interviewed to ascertain the current level and opinion of training in paediatric protocols, in-house educational programs and the implementation of radiation dose saving parameters. Radiographers demonstrated reasonable ability to identify suitable paediatric protocols and believed the in-house CT protocols resident to their medical imaging department to be adequate, despite many utilising exposures higher than those from recommended literature. The interviews revealed that no further training in CT paediatric dose reduction was currently available, however survey responses indicated that further training would be beneficial. This study demonstrates that radiographers are aware of the need to reduce exposure parameters for paediatric CT and tend to follow protocols in place within their workplace, regardless of suitability and patient needs Copyright (2003) Australian Institute of Radiography

  12. Glandular dose in breast tomosynthesis examinations: Preliminary study with a sample of patients

    International Nuclear Information System (INIS)

    Castillo, M.; Chevalier, M.; Calzado, A.; Valverde, J.

    2013-01-01

    The aim of this study is to analyze the mean glandular dose administered to a group of patients with a tomography system (Selenia Dimensions) service installed on a large hospital in which routine tests are done and screening. (Author)

  13. Evaluation of general-purpose collimators against high-resolution collimators with resolution recovery with a view to reducing radiation dose in myocardial perfusion SPECT: A preliminary phantom study.

    Science.gov (United States)

    Armstrong, Ian S; Saint, Kimberley J; Tonge, Christine M; Arumugam, Parthiban

    2017-04-01

    There is a growing focus on reducing radiation dose to patients undergoing myocardial perfusion imaging. This preliminary phantom study aims to evaluate the use of general-purpose collimators with resolution recovery (RR) to allow a reduction in patient radiation dose. Images of a cardiac torso phantom with inferior and anterior wall defects were acquired on a GE Infinia and Siemens Symbia T6 using both high-resolution and general-purpose collimators. Imaging time, a surrogate for administered activity, was reduced between 35% and 40% with general-purpose collimators to match the counts acquired with high-resolution collimators. Images were reconstructed with RR with and without attenuation correction. Two pixel sizes were also investigated. Defect contrast was measured. Defect contrast on general-purpose images was superior or comparable to the high-resolution collimators on both systems despite the reduced imaging time. Infinia general-purpose images required a smaller pixel size to be used to maintain defect contrast, while Symbia T6 general-purpose images did not require a change in pixel size to that used for standard myocardial perfusion SPECT. This study suggests that general-purpose collimators with RR offer a potential for substantial dose reductions while providing similar or better image quality to images acquired using high-resolution collimators.

  14. Data Center Energy Efficiency Standards in India: Preliminary Findings from Global Practices

    Energy Technology Data Exchange (ETDEWEB)

    Raje, Sanyukta; Maan, Hermant; Ganguly, Suprotim; Singh, Tanvin; Jayaram, Nisha; Ghatikar, Girish; Greenberg, Steve; Kumar, Satish; Sartor, Dale

    2015-06-01

    Global data center energy consumption is growing rapidly. In India, information technology industry growth, fossil-fuel generation, and rising energy prices add significant operational costs and carbon emissions from energy-intensive data centers. Adoption of energy-efficient practices can improve the global competitiveness and sustainability of data centers in India. Previous studies have concluded that advancement of energy efficiency standards through policy and regulatory mechanisms is the fastest path to accelerate the adoption of energy-efficient practices in the Indian data centers. In this study, we reviewed data center energy efficiency practices in the United States, Europe, and Asia. Using evaluation metrics, we identified an initial set of energy efficiency standards applicable to the Indian context using the existing policy mechanisms. These preliminary findings support next steps to recommend energy efficiency standards and inform policy makers on strategies to adopt energy-efficient technologies and practices in Indian data centers.

  15. CT findings of pancreatic carcinoma. Evaluation with the combined method of early enhancement CT and high dose enhancement CT

    International Nuclear Information System (INIS)

    Itoh, Shigeki; Endo, Tokiko; Isomura, Takayuki; Ishigaki, Takeo; Ikeda, Mitsuru; Senda, Kouhei.

    1995-01-01

    Computed tomographic (CT) findings of pancreatic ductal adenocarcinoma were studied with the combined method of early enhancement CT and high dose enhancement CT in 72 carcinomas. Common Findings were change in pancreatic contour, abnormal attenuation in a tumor and dilatation of the main pancreatic duct. The incidence of abnormal attenuation and dilatation of the main pancreatic duct and bile duct was constant regardless of tumor size. The finding of hypoattenuation at early enhancement CT was most useful for demonstrating a carcinoma. However, this finding was negative in ten cases, five of which showed inhomogenous hyperattenuation at high dose enhancement CT. The detection of change in pancreatic contour and dilatation of the main pancreatic duct was most frequent at high dose enhancement CT. The finding of change in pancreatic contour and/or abnormal attenuation in a tumor could be detected in 47 cases at plain CT, 66 at early enhancement CT and 65 at high dose enhancement CT. Since the four cases in which neither finding was detected by any CT method showed dilatated main pancreatic duct, there was no case without abnormal CT findings. This combined CT method will be a reliable diagnostic technique in the imaging of pancreatic carcinoma. (author)

  16. A study on gamma dose rate in Seoul (I)

    International Nuclear Information System (INIS)

    Kim, You Hyun; Kim, Chang Kyun; Choi, Jong Hak; Kim, Jeong Min

    2001-01-01

    This study was conducted to find out gamma dose rate in Seoul, from January to December in 2000, and the following results were achieved : The annual gamma dose rate in Seoul was 17.24 μR/hr as average. The annual gamma dose rate in subway of Seoul was 14.96 μR/hr as average. The highest annual gamma dose rate was Dong-daemon ku. Annual gamma dose rate in Seoul was higher autumn than winter

  17. Do preliminary chest X-ray findings define the optimum role of pulmonary scintigraphy in suspected pulmonary embolism?

    International Nuclear Information System (INIS)

    Forbes, Kirsten P.N.; Reid, John H.; Murchison, John T.

    2001-01-01

    AIM: To investigate if preliminary chest radiograph (CXR) findings can define the optimum role of lung scintigraphy in subjects investigated for pulmonary embolism (PE). MATERIALS AND METHODS: The CXR and scintigraphy findings from 613 consecutive subjects investigated for suspected PE were retrieved from a radiological database. Of 393 patients with abnormal CXRs, a subgroup of 238 was examined and individual radiographic abnormalities were characterized. CXR findings were related to the scintigraphy result. RESULTS: Scintigraphy was normal in 286 subjects (47%), non-diagnostic in 207 (34%) and high probability for PE in 120 (20%). In 393 subjects (64%) the preliminary CXR was abnormal and 188 (48%) of scintigrams in this group were non-diagnostic. Individual radiographic abnormalities were not associated with significantly different scintigraphic outcomes. If the preliminary CXR was normal (36%), the proportion of non-diagnostic scintigrams decreased to 9% (19 of 220 subjects) (P < 0.05). CONCLUSION: In subjects investigated for PE, an abnormal CXR increases the prevalence of non-diagnostic scintigrams. A normal pre-test CXR is more often associated with a definitive (normal or high probability) scintigram result. The chest radiograph may be useful in deciding the optimum sequence of investigations. Forbes, K.P.N., Reid, J.H., Murchison, J.T. (2001)

  18. A preliminary assessment of potential doses to man from radioactive waste dumped in the Arctic Sea

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, S P [Forskningscente Risoe, Roskilde (Denmark); Iosjpe, M; Strand, P [Norwegian Radiation Protection Authority, Oesteraas (Norway)

    1995-09-01

    This report describes a preliminary radiological assessment of collective doses to the world population from radioactive material dumped in the Barents and Kara Seas in the period 1961-1991. Information on the dumped waste and the rates of release of radionuclides have been available from Russian sources and from the International Atomic Energy Agency. A box model has been used to simulate the dispersion of radionuclides in the marine environment and to calculate the contamination of seafood and the subsequent radiation doses to man. Two release scenarios have been adopted. The worst-case release scenario which ignores the presence of barriers between spent nuclear fuel and seawater is estimated to give rise to about 10 mansieverts calculated to 1000 years from the time of release. A more realistic release scenario is estimated to cause about 3 mansieverts. In both cases exposure from the radionuclide {sup 137}Cs is found to dominate the doses. (au) 8 tabs., 56 ills., 19 refs.

  19. A preliminary assessment of potential doses to man from radioactive waste dumped in the Arctic sea

    International Nuclear Information System (INIS)

    Nielsen, S.P.; Iosjpe, M.; Strand, P.

    1995-11-01

    This report describes a preliminary radiological assessment of collective doses to the world population from radioactive material dumped in the Kara and Barents Seas in the period 1961-1991. Information on the dumped waste and the rates of release of radionuclides have been available from Russian sources and from the International Atomic Energy Agency. A box model has been used to simulate the dispersion of radionuclides in the marine environment and to calculate the contamination of seafood and the subsequent radiation doses to man. Two release scenarios have been adopted. The worst-case release scenario, which ignores the presence of barriers between spent nuclear fuel and seawater, is estimated to give rise to about 10 mansievert calculated to 1000 years from the time of release. A more realistic release scenario is estimated to cause about 3 mansieverts. In both cases exposure from the radionuclide 137 Cs is found to dominate the doses. 19 refs., 56 figs., 8 tabs

  20. A preliminary assessment of potential doses to man from radioactive waste dumped in the Arctic Sea

    International Nuclear Information System (INIS)

    Nielsen, S.P.; Iosjpe, M.; Strand, P.

    1995-09-01

    This report describes a preliminary radiological assessment of collective doses to the world population from radioactive material dumped in the Barents and Kara Seas in the period 1961-1991. Information on the dumped waste and the rates of release of radionuclides have been available from Russian sources and from the International Atomic Energy Agency. A box model has been used to simulate the dispersion of radionuclides in the marine environment and to calculate the contamination of seafood and the subsequent radiation doses to man. Two release scenarios have been adopted. The worst-case release scenario which ignores the presence of barriers between spent nuclear fuel and seawater is estimated to give rise to about 10 mansieverts calculated to 1000 years from the time of release. A more realistic release scenario is estimated to cause about 3 mansieverts. In both cases exposure from the radionuclide 137 Cs is found to dominate the doses. (au) 8 tabs., 56 ills., 19 refs

  1. Preliminary Radiation Analysis of the Total Ionizing Dose for the Resource Prospector Mission

    Science.gov (United States)

    Rojdev, Kristina; Tylka, Allan J.; Atwell, William

    2015-01-01

    NASA's Resource Prospector (RP) is a collaborative project between multiple centers and institutions to search for volatiles at the polar regions of the Moon as a potential resource for oxygen and propellant production. The mission is rated Class D and will be the first In-Situ Resource Utilization (ISRU) demonstration on the lunar surface and at the lunar poles. Given that this mission is rated Class D, the project is considering using commercial off the shelf (COTS) electronics parts to reduce cost. However, COTS parts can be more susceptible to space radiation than typical aerospace electronic parts and carry some additional risk. Thus, prior to parts selection, having a better understanding of the radiation environment can assist designers in the parts selection process. The focus of this paper is to provide a preliminary analysis of the radiation environment from launch, through landing on the surface, and some surface stay as an initial step in determining worst case mission doses to assist designers in screening out electronic parts that would not meet the potential dose levels experienced on this mission.

  2. Preliminary studies on the optimization of countermeasures for agricultural areas

    Energy Technology Data Exchange (ETDEWEB)

    Rochedo, Elaine R.R.; Igreja, Eduardo; Barboza, Adriana E., E-mail: elainerochedo@gmail.com, E-mail: eduigreja@gmail.com, E-mail: adrianaebarboza@gmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil); Silva, Diogo N.G. da; Guimaraes, Jean R.D., E-mail: diogons@gmail.com, E-mail: jeanrdg@biof.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Instituto de Biofisica Carlos Chagas Filho; Wasserman, Maria Angelica V., E-mail: mwasserman@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Perez, Daniel V. [Centro Nacional de Pesquisa de Solos (EMBRAPA), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    The assessment of remediation measures for rural areas is more complex than that for urban ones, due to the influence of large number of variables associated with climate, diet, farming practices and the type of soil. Thus, it is not possible to perform generic studies applicable to all types of area. Specific studies and surveys should be made in the areas most likely to contamination from a nuclear accident. Preliminary studies demonstrated that the different soil types in Brazil is more relevant to the ingestion dose than the regional differences in diets. Other studies have described the prioritization of areas and products for detailed survey on soil types and remediation procedures, for an accident at the NPP in Angra dos Reis, based on radiological and economic aspects. The most relevant product was milk, due to both its relevance to the intake and the loss of income for the counties. The contribution of milk to dose depends on the season of the year when the accident occurs, mainly due to the relative contribution of other items of the diet. The timing of the application of the countermeasure has an important effect on the dose reduction that can be achieved. For I-131, protective measures must be considered within the emergency phase in order to be effective. The main action on reducing ingestion doses is the removal of food items from diet, while providing clean food to the population. (author)

  3. Preliminary studies on the optimization of countermeasures for agricultural areas

    International Nuclear Information System (INIS)

    Rochedo, Elaine R.R.; Igreja, Eduardo; Barboza, Adriana E.; Silva, Diogo N.G. da; Guimaraes, Jean R.D.; Perez, Daniel V.

    2015-01-01

    The assessment of remediation measures for rural areas is more complex than that for urban ones, due to the influence of large number of variables associated with climate, diet, farming practices and the type of soil. Thus, it is not possible to perform generic studies applicable to all types of area. Specific studies and surveys should be made in the areas most likely to contamination from a nuclear accident. Preliminary studies demonstrated that the different soil types in Brazil is more relevant to the ingestion dose than the regional differences in diets. Other studies have described the prioritization of areas and products for detailed survey on soil types and remediation procedures, for an accident at the NPP in Angra dos Reis, based on radiological and economic aspects. The most relevant product was milk, due to both its relevance to the intake and the loss of income for the counties. The contribution of milk to dose depends on the season of the year when the accident occurs, mainly due to the relative contribution of other items of the diet. The timing of the application of the countermeasure has an important effect on the dose reduction that can be achieved. For I-131, protective measures must be considered within the emergency phase in order to be effective. The main action on reducing ingestion doses is the removal of food items from diet, while providing clean food to the population. (author)

  4. A double-blind, randomized, pilot dose-finding study of maca root (L. meyenii) for the management of SSRI-induced sexual dysfunction.

    Science.gov (United States)

    Dording, Christina M; Fisher, Lauren; Papakostas, George; Farabaugh, Amy; Sonawalla, Shamsah; Fava, Maurizio; Mischoulon, David

    2008-01-01

    We sought to determine whether maca, a Peruvian plant, is effective for selective-serotonin reuptake inhibitor (SSRI)-induced sexual dysfunction. We conducted a double-blind, randomized, parallel group dose-finding pilot study comparing a low-dose (1.5 g/day) to a high-dose (3.0 g/day) maca regimen in 20 remitted depressed outpatients (mean age 36+/-13 years; 17 women) with SSRI-induced sexual dysfunction. The Arizona Sexual Experience Scale (ASEX) and the Massachusetts General Hospital Sexual Function Questionnaire (MGH-SFQ) were used to measure sexual dysfunction. Ten subjects completed the study, and 16 subjects (9 on 3.0 g/day; 7 on 1.5 g/day) were eligible for intent-to-treat (ITT) analyses on the basis of having had at least one postbaseline visit. ITT subjects on 3.0 g/day maca had a significant improvement in ASEX (from 22.8+/-3.8 to 16.9+/-6.2; z=-2.20, P=0.028) and in MGH-SFQ scores (from 24.1+/-1.9 to 17.0+/-5.7; z=-2.39, P=0.017), but subjects on 1.5 g/day maca did not. Libido improved significantly (PMaca was well tolerated. Maca root may alleviate SSRI-induced sexual dysfunction, and there may be a dose-related effect. Maca may also have a beneficial effect on libido.

  5. Analgesic and sedative effects of perioperative gabapentin in total knee arthroplasty A randomized, double-blind, placebo-controlled, dose-finding study

    DEFF Research Database (Denmark)

    Lunn, Troels Haxholdt; Husted, Henrik; Laursen, Mogens Berg

    2015-01-01

    (1:1:1) to either gabapentin 1300 mg/d (group A), gabapentin 900 mg/d (group B), or placebo (group C) daily from 2 hours preoperatively to postoperative day 6 in addition to a standardized multimodal analgesic regime. The primary outcome was pain upon ambulation 24 hours after surgery......Gabapentin has shown acute postoperative analgesic effects, but the optimal dose and procedure-specific benefits vs harm have not been clarified. In this randomized, double-blind, placebo-controlled dose-finding study, 300 opioid-naive patients scheduled for total knee arthroplasty were randomized......, and the secondary outcome was sedation 6 hours after surgery. Other outcomes were overall pain during well-defined mobilizations and at rest and sedation during the first 48 hours and from days 2-6, morphine use, anxiety, depression, sleep quality, and nausea, vomiting, dizziness, concentration difficulty, headache...

  6. Preliminary 2D design study for A ampersand PCT

    International Nuclear Information System (INIS)

    Keto, E.; Azevedo, S.; Roberson, P.

    1995-03-01

    Lawrence Livermore National Laboratory is currently designing and constructing a tomographic scanner to obtain the most accurate possible assays of radioactivity in barrels of nuclear waste in a limited amount of time. This study demonstrates a method to explore different designs using laboratory experiments and numerical simulations. In particular, we examine the trade-off between spatial resolution and signal-to-noise. The simulations are conducted in two dimensions as a preliminary study for three dimensional imaging. We find that the optimal design is entirely dependent on the expected source sizes and activities. For nuclear waste barrels, preliminary results indicate that collimators with widths of 1 to 3 inch and aspect ratios of 5:1 to 10:1 should perform well. This type of study will be repeated in 3D in more detail to optimize the final design

  7. Preliminary phytochemical, acute oral toxicity and antihepatotoxic study of roots of Paeonia officinalis Linn.

    Science.gov (United States)

    Ahmad, Feroz; Tabassum, Nahida

    2013-01-01

    To carry out a preliminary phytochemical, acute oral toxicity and antihepatotoxic study of the roots of Paeonia officinalis (P. officinalis) L. Preliminary phytochemical investigation was done as per standard procedures. Acute oral toxicity study was conducted as per OECD 425 guidelines. The antihepatotoxic activity of aqueous extract of root of P. officinalis was evaluated against carbon tetrachloride (CCl4) induced hepatic damage in rats. Aqueous extract of P. officinalis at the dose levels of 100 and 200 mg/kg body weight was administered daily for 14 d in experimental animals. Liver injury was induced chemically, by CCl4 administration (1 mL/kg i.p.). The hepatoprotective activity was assessed using various biochemical parameters like aspartate aminotransferase (AST), alanine aminotransferase (ALT), serum alkaline phosphatase (SALP), total bilirubin and total protein (TP) along with histopathological studies. Phytochemical screening revealed that the roots of P. officinalis contain alkaloids, tannins, saponins, glycosides, carbohydrates, flavonoids, terpenes, steroids and proteins. The aqueous extract did not cause any mortality up to 2 000 mg/kg. In rats that had received the root extract at the dose of 100 and 200 mg/kg, the substantially elevated AST, ALT, SALP, total bilirubin levels were significantly lowered, respectively, in a dose dependent manner, along with CCl4 while TP levels were elevated in these groups. Histopathology revealed regeneration of the livers in extract treated groups while Silymarin treated rats were almost normal. The aqueous extract of P. officinalis is safe and possesses antihepatotoxic potential.

  8. Phase 1 dose-escalation study of the antiplacental growth factor monoclonal antibody RO5323441 combined with bevacizumab in patients with recurrent glioblastoma

    DEFF Research Database (Denmark)

    Lassen, Ulrik; Chinot, Olivier L; McBain, Catherine

    2015-01-01

    BACKGROUND: We conducted a phase 1 dose-escalation study of RO5323441, a novel antiplacental growth factor (PlGF) monoclonal antibody, to establish the recommended dose for use with bevacizumab and to investigate the pharmacokinetics, pharmacodynamics, safety/tolerability, and preliminary clinica...

  9. Laboratory Bioaccumulation, Depuration And Total Dose Rate Of Waterborne Th-232 In Freshwater Fish Of Anabas Testudineus

    International Nuclear Information System (INIS)

    Zal U'yun Wan Mahmood; Norfaizal Mohamed; Nita Salina Abu Bakar

    2014-01-01

    Preliminary results on the study of bioaccumulation, depuration and total dose rate of Th-232 in the whole body of Anabas testudineus are presented. The objective of this study was to evaluate the effect of Th-232 concentration activity on the laboratory bioaccumulation, depuration and total dose rate in Anabas testudineus. Anabas testudineus adults were exposed to different waterborne Th-232 levels: 0 BqL -1 (control), 50 BqL -1 and 100 BqL -1 for 30 day (uptake phase), followed by exposure to radionuclide-free water for 30 days (loss phase). Radionuclide concentration ratios between the whole body levels and water levels, percentage of Th-232 remaining in fish were calculated and total dose rates using ERICA Assessment Tool were also estimated. The results showed the increase of waterborne Th-232 concentration corresponded to a progressive increase of Th accumulation and total dose rate (internal and external) in the whole body of Anabas testudineus. Considering the ERICA dose rate screening value of 10 μGyh -1 , the findings can be concluded the estimated of total dose rate (< 5 μGyh -1 ) in Anabas testudineus is in order of small magnitude. Nevertheless, these preliminary results showed that the Anabas testudineus has a potential to accumulate thorium. (author)

  10. Adaptive designs for dose-finding in non-cancer phase II trials: influence of early unexpected outcomes.

    Science.gov (United States)

    Resche-Rigon, Matthieu; Zohar, Sarah; Chevret, Sylvie

    2008-01-01

    In non-cancer phase II trials, dose-finding trials are usually carried out using fixed designs, in which several doses including a placebo are randomly distributed to patients. However, in certain vulnerable populations, such as neonates or infants, there is an heightened requirement for safety, precluding randomization. To estimate the minimum effective dose of a new drug from a non-cancer phase II trial, we propose the use of adaptive designs like the Continual Reassessment Method (CRM). This approach estimates the dose closest to some target response, and has been shown to be unbiased and efficient in cancer phase I trials. Based on a motivating example, we point out the individual influence of first outliers in this setting. A weighted version of the CRM is proposed as a theoretical benchmark to control for these outliers. Using simulations, we illustrate how this approach provides further insight into the behavior of the CRM. When dealing with low targets like a 10% failure rate, the CRM appears unable to rapidly overcome an early unexpected outcome. This behavior persisted despite changing the inference (Bayesian or likelihood), underlying dose-response model (though slightly improved using the power model), and the number of patients enrolled at each dose level. The choices for initial guesses of failure rates, the vague prior for the model parameter, and the log-log shape of weights can appear somewhat arbitrary. In phase II dose-finding studies in which failure targets are below 20%, the CRM appears quite sensitive to first unexpected outcomes. Using a power model for dose-response improves some behavior if the trial is started at the first dose level and includes at least three to five patients at the starting dose before applying the CRM allocation rule.

  11. Online gaming dependency: a preliminary study in China.

    Science.gov (United States)

    Peng, Wei; Liu, Ming

    2010-06-01

    Based on theories and previous studies on problematic Internet use, we propose a model to better understand the contributors to and consequences of online gaming dependency. A preliminary study was conducted through a survey of online gamers in China. The results of path analysis found that maladaptive cognitions, shyness, and depression are positively related to online gaming dependency. Online gaming dependency was also positively related to different types of negative life outcomes. The findings of this study have implications for the prevention and treatment of addictive online gaming.

  12. Preliminary study of using imaging plates to map skin dose of patients in interventional radiology procedures

    International Nuclear Information System (INIS)

    Ohuchi, H.; Satoh, T.; Eguchi, Y.; Mori, K.

    2005-01-01

    A method using europium-doped BaFBr imaging plates (IPs) has been studied for mapping entrance skin doses during interventional radiology (IR); the mapping is useful for detecting overlap between irradiation fields and determining the most exposed skin areas. IPs, which are two-dimensional radiation sensors made of photostimulated luminescence materials, have a linear dose response up to ∼100 Gy, can accurately measure doses from 1 μGy to 10 Gy and can be used repeatedly. Because the energy dependence of IPs is rather high, the IPs were characterised in this study and a sensitivity variation of ∼13% was observed for effective energies of 32.7 to 44.7 keV, which are used in IR procedures. Simulation of actual interventional cardiology procedures showed that the variation of sensitivity was within 5%, meaning that IPs are practical for measuring skin doses during IR. Moreover, the patient data can be stored online and easily called up when IR procedures must be repeated, helping to prevent radiation injuries. (authors)

  13. Preliminary clinical findings on NEUMUNE as a potential treatment for acute radiation syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Stickney, Dwight R; Groothuis, Jessie R; Ahlem, Clarence; Kennedy, Mike; Miller, Barry S; Onizuka-Handa, Nanette; Schlangen, Karen M; Destiche, Daniel; Reading, Chris; Garsd, Armando; Frincke, James M [Harbor Biosciences, 9171 Towne Centre Drive, Suite 180, San Diego, CA 92122 (United States)

    2010-12-01

    5-androstenediol (5-AED) has been advanced as a possible countermeasure for treating the haematological component of acute radiation syndrome (ARS). It has been used in animal models to stimulate both innate and adaptive immunity and treat infection and radiation-induced immune suppression. We here report on the safety, tolerability and haematologic activity of 5-AED in four double-blinded, randomized, placebo-controlled studies on healthy adults including elderly subjects. A 5-AED injectable suspension formulation (NEUMUNE) or placebo was administered intramuscularly as either a single injection, or once daily for five consecutive days at doses of 50, 100, 200 or 400 mg. Subjects (n = 129) were randomized to receive NEUMUNE (n = 95) or the placebo (n = 34). NEUMUNE was generally well-tolerated; the most frequent adverse events were local injection site reactions (n = 104, 81%) that were transient, dose-volume dependent, mild to moderate in severity, and that resolved over the course of the study. Blood chemistries revealed a transient increase (up to 28%) in creatine phosphokinase and C-reactive protein levels consistent with intramuscular injection and injection site irritation. The blood concentration profile of 5-AED is consistent with a depot formulation that increases in disproportionate increments following each dose. NEUMUNE significantly increased circulating neutrophils (p < 0.001) and platelets (p < 0.001) in the peripheral blood of adult and elderly subjects. A dose-response relationship was identified. Findings suggest that parenteral administration of 5-AED in aqueous suspension may be a safe and effective means to stimulate innate immunity and alleviate neutropenia and thrombocytopenia associated with ARS.

  14. Preliminary clinical findings on NEUMUNE as a potential treatment for acute radiation syndrome

    International Nuclear Information System (INIS)

    Stickney, Dwight R; Groothuis, Jessie R; Ahlem, Clarence; Kennedy, Mike; Miller, Barry S; Onizuka-Handa, Nanette; Schlangen, Karen M; Destiche, Daniel; Reading, Chris; Garsd, Armando; Frincke, James M

    2010-01-01

    5-androstenediol (5-AED) has been advanced as a possible countermeasure for treating the haematological component of acute radiation syndrome (ARS). It has been used in animal models to stimulate both innate and adaptive immunity and treat infection and radiation-induced immune suppression. We here report on the safety, tolerability and haematologic activity of 5-AED in four double-blinded, randomized, placebo-controlled studies on healthy adults including elderly subjects. A 5-AED injectable suspension formulation (NEUMUNE) or placebo was administered intramuscularly as either a single injection, or once daily for five consecutive days at doses of 50, 100, 200 or 400 mg. Subjects (n = 129) were randomized to receive NEUMUNE (n = 95) or the placebo (n = 34). NEUMUNE was generally well-tolerated; the most frequent adverse events were local injection site reactions (n = 104, 81%) that were transient, dose-volume dependent, mild to moderate in severity, and that resolved over the course of the study. Blood chemistries revealed a transient increase (up to 28%) in creatine phosphokinase and C-reactive protein levels consistent with intramuscular injection and injection site irritation. The blood concentration profile of 5-AED is consistent with a depot formulation that increases in disproportionate increments following each dose. NEUMUNE significantly increased circulating neutrophils (p < 0.001) and platelets (p < 0.001) in the peripheral blood of adult and elderly subjects. A dose-response relationship was identified. Findings suggest that parenteral administration of 5-AED in aqueous suspension may be a safe and effective means to stimulate innate immunity and alleviate neutropenia and thrombocytopenia associated with ARS.

  15. Can a single dose of human papillomavirus (HPV) vaccine prevent cervical cancer? Early findings from an Indian study.

    Science.gov (United States)

    Sankaranarayanan, Rengaswamy; Joshi, Smita; Muwonge, Richard; Esmy, Pulikottil Okkuru; Basu, Partha; Prabhu, Priya; Bhatla, Neerja; Nene, Bhagwan M; Shaw, Janmesh; Poli, Usha Rani Reddy; Verma, Yogesh; Zomawia, Eric; Pimple, Sharmila; Tommasino, Massimo; Pawlita, Michael; Gheit, Tarik; Waterboer, Tim; Sehr, Peter; Pillai, Madhavan Radhakrishna

    2018-03-15

    Human papillomavirus (HPV) vaccination is a major strategy for preventing cervical and other ano-genital cancers. Worldwide HPV vaccination introduction and coverage will be facilitated if a single dose of vaccine is as effective as two or three doses or demonstrates significant protective effect compared to 'no vaccination'. In a multi-centre cluster randomized trial of two vs three doses of quadrivalent HPV vaccination (Gardasil™) in India, suspension of the vaccination due to events unrelated to the study led to per protocol and partial vaccination of unmarried 10-18 year old girls leading to four study groups, two by design and two by default. They were followed up for the primary outcomes of immunogenicity in terms of L1 genotype-specific binding antibody titres, neutralising antibody titres, and antibody avidity for the vaccine-targeted HPV types and HPV infections. Analysis was per actual number of vaccine doses received. This study is registered with ISRCTN, number ISRCTN98283094; and with ClinicalTrials.gov, number NCT00923702. Of the 17,729 vaccinated girls, 4348 (25%) received three doses on days 1, 60, 180 or later, 4979 (28%) received two doses on days 1 and 180 or later, 3452 (19%) received two doses on days 1 and 60, and 4950 (28%) received one dose. One dose recipients demonstrated a robust and sustained immune response against HPV 16 and 18, albeit inferior to that of 3- or 2-doses and the antibody levels were stable over a 4 year period. The frequencies of cumulative incident and persistent HPV 16 and 18 infections up to 7 years of follow-up were similar and uniformly low in all the vaccinated study groups; the frequency of HPV 16 and 18 infections were significantly higher in unvaccinated age-matched control women than among vaccine recipients. The frequency of vaccine non-targeted HPV types was similar in the vaccinated groups but higher in the unvaccinated control women. Our results indicate that a single dose of quadrivalent HPV

  16. Measurement of spatial dose distribution for evaluation operator dose during nero-interventional procedures

    International Nuclear Information System (INIS)

    Han, Su Chul; Hong, Dong Hee

    2016-01-01

    The spatial dose distribution was measured with ionization chamber as preliminary study to evaluate operator dose and to study dose reduction during neuro-interventional procedures. The zone of operators was divided into four area (45, 135, 225, and 315 degree).We supposed that operator exist on the four area and indicated location of critical organs(eyes, breast, gonad). The spatial doses were measured depending on distance( 80, 100, 120, and 140 cm) and location of critical organs. The spatial doses of area of 225 degree were 114.5 mR/h (eyes location), 143.1 mR/h (breast location) and 147 mR/h (gonad location) in 80 cm. When changed location of x-ray generator, spatial dose increased in 18.1±10.5%, averagely. We certified spatial dose in the operator locations, Using the results of this study, It is feasible to protect operator from radiation in neuro-interventional procedures

  17. Measurement of spatial dose distribution for evaluation operator dose during nero-interventional procedures

    Energy Technology Data Exchange (ETDEWEB)

    Han, Su Chul [Division of Medical Radiation Equipment, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Hong, Dong Hee [Dept. of Radiology Science, Far East University, Eumseong (Korea, Republic of)

    2016-09-15

    The spatial dose distribution was measured with ionization chamber as preliminary study to evaluate operator dose and to study dose reduction during neuro-interventional procedures. The zone of operators was divided into four area (45, 135, 225, and 315 degree).We supposed that operator exist on the four area and indicated location of critical organs(eyes, breast, gonad). The spatial doses were measured depending on distance( 80, 100, 120, and 140 cm) and location of critical organs. The spatial doses of area of 225 degree were 114.5 mR/h (eyes location), 143.1 mR/h (breast location) and 147 mR/h (gonad location) in 80 cm. When changed location of x-ray generator, spatial dose increased in 18.1±10.5%, averagely. We certified spatial dose in the operator locations, Using the results of this study, It is feasible to protect operator from radiation in neuro-interventional procedures.

  18. Radiation dose in vertebroplasty

    International Nuclear Information System (INIS)

    Mehdizade, A.; Lovblad, K.O.; Wilhelm, K.E.; Somon, T.; Wetzel, S.G.; Kelekis, A.D.; Yilmaz, H.; Abdo, G.; Martin, J.B.; Viera, J.M.; Ruefenacht, D.A.

    2004-01-01

    We wished to measure the absorbed radiation dose during fluoroscopically controlled vertebroplasty and to assess the possibility of deterministic radiation effects to the operator. The dose was measured in 11 consecutive procedures using thermoluminescent ring dosimeters on the hand of the operator and electronic dosimeters inside and outside of the operator's lead apron. We found doses of 0.022-3.256 mGy outside and 0.01-0.47 mGy inside the lead apron. Doses on the hand were higher, 0.5-8.5 mGy. This preliminary study indicates greater exposure to the operator's hands than expected from traditional apron measurements. (orig.)

  19. In vivo radioprotection by alpha-TMG: preliminary studies.

    Science.gov (United States)

    Satyamitra, M; Devi, P U; Murase, H; Kagiya, V T

    2001-08-08

    alpha-TMG is a novel water-soluble derivative of Vitamin E that has shown excellent antioxidant activity. The parent compound has demonstrated protection against radiation induced chromosomal damage in vivo. Hence, the preliminary experiments to determine the radioprotective activity of alpha-TMG were carried out in adult Swiss albino mice. Acute toxicity of the drug was studied taking 24h, 72 h and 30 day mortality after a single intraperitoneal injection of 500-2000 mg/kg body weight of the drug. The drug LD(50) for 24h and 72 h/30 day survival were found to be 1120 and 1000 mg/kg body weight, respectively. The optimum time of drug administration and drug dose-dependent effect on in vivo radiation protection of bone marrow chromosomes was studied in mice. Injection of 600 mg/kg of the drug 15 min before or within 5, 15 or 30min after 3Gy whole body gamma radiation resulted in a significant decrease in the aberrant metaphases percent at 24h post-irradiation; the maximum effect was seen when the drug was given immediately after irradiation. Injection of 200-800 mg/kg TMG within 5 min of irradiation with 3 Gy produced a significant dose-dependent reduction in the radiation induced percent aberrant metaphases and in the frequency of micronucleated erythrocytes at 24h after exposure, with a corresponding decrease in the different types of aberrations. The optimum dose for protection without drug toxicity was 600 mg/kg body weight. At this dose, TMG produced 70 and >60% reduction in the radiation induced percent aberrant metaphases and micronucleated erythrocytes, respectively. The high water solubility and effectiveness when administered post-irradiation favor TMG as a likely candidate for protection in case of accidental exposures.

  20. A phenomenographic investigation into Information Literacy in nursing practice - preliminary findings and methodological issues.

    Science.gov (United States)

    Forster, Marc

    2013-10-01

    Information Literacy is essential to 'evidence-based practice'; without the ability to locate evidence, evidence-based practice is rendered extremely difficult if not impossible. There is currently little evidence to show how Information Literacy is experienced by nurses or what its parameters are within evidence-based practice and therefore whether Information Literacy educational interventions are actually promoting the correct knowledge and skills. Using phenomenographic interviews the author will attempt to discover how nurses experience Information Literacy. Insights from the findings will be used to map out its parameters and to put forward a theoretical model for a course or module to develop it effectively. This article presents preliminary findings, including 7 draft categories of description of how Information Literacy is experienced in nursing. This pilot study indicates that the complete findings may be of significant potential value in the promotion and development of Information Literacy education in nursing. It is argued that such insights into how nurses actually experience the phenomenon of Information Literacy can be used to develop potentially more effective, research-based, educational interventions. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Single-dose fosaprepitant for the prevention of chemotherapy-induced nausea and vomiting associated with cisplatin therapy: randomized, double-blind study protocol--EASE

    DEFF Research Database (Denmark)

    Grunberg, Steven; Chua, Daniel; Maru, Anish

    2011-01-01

    multiple-day NK1RA administration. Preliminary data suggested that single-dose aprepitant before chemotherapy could provide CINV protection throughout the overall risk phase (OP; 0 to 120 hours). This study compared a 3-day oral aprepitant schedule to a regimen containing a single dose of the intravenous...

  2. Preliminary nuclear decommissioning cost study

    International Nuclear Information System (INIS)

    Sissingh, R.A.P.

    1981-04-01

    The decommissioning of a nuclear power plant may involve one or more of three possible options: storage with surveillance (SWS), restricted site release (RSR), and unrestricted site use(USU). This preliminary study concentrates on the logistical, technical and cost aspects of decommissioning a multi-unit CANDU generating station using Pickering GS as the reference design. The procedure chosen for evaluation is: i) removal of the fuel and heavy water followed by decontamination prior to placing the station in SWS for thiry years; ii) complete dismantlement to achieve a USU state. The combination of SWS and USU with an interim period of surveillance allows for radioactive decay and hence less occupational exposure in achieving USU. The study excludes the conventional side of the station, assumes waste disposal repositories are available 1600 km away from the station, and uses only presently available technologies. The dismantlement of all systems except the reactor core can be accomplished using Ontario Hydro's current operating, maintenance and construction procedures. The total decommissioning period is spread out over approximately 40 years, with major activities concentrated in the first and last five years. The estimated dose would be approximately 1800 rem. Overall Pickering GS A costs would be $162,000,000 (1980 Canadian dollars)

  3. Validation of dose-response curve of CRCN-NE - Regional Center for Nuclear Sciences from Northeast Brazil for 60Co: preliminary results

    International Nuclear Information System (INIS)

    Mendonca, Julyanne C.G.; Mendes, Mariana E.; Hwang, Suy F.; Lima, Fabiana F.; Santos, Neide

    2014-01-01

    The cytogenetic study has the chromosomal alterations as biomarkers in absorbed dose estimation by the body of individuals involved in exposure to ionizing radiation by interpreting a dose response calibration curve. Since the development of the technique to the analysis of data, you can see protocol characteristics, leading the International Atomic Energy Agency indicate that any laboratory with intention to carry out biological dosimetry establish their own calibration curves. The Biological Dosimetry Laboratory of the Centro Regional de Ciencias Nucleares (CRCN-NE/CNEN), Brazil, recently established the calibration curve related to gamma radiation ( 60 Co). Thus, this work aimed to start the validation of this calibration curve from samples of three different blood donors which were irradiated with an absorbed known single dose of 1 Gy. Samples were exposed to 60 Co source (Glaucoma 220) located in the Department of Nuclear Energy (DEN/UFPE). After fixation with methanol and acetic acid and 5% Giemsa staining, the frequency of chromosomal alterations (dicentric chromosomes, acentric rings and fragments) were established from reading of 500 metaphases per sample and doses were estimated using Dose Estimate program. The results showed that, using the dose-response curve calibration for dicentrics, the dose absorbed estimated for the three individuals ranged from 0.891 - 1,089Gy, taking into account the range of confidence of 95%. By using the dose-response curve for dicentrics added to rings and for the same interval of confidence the doses ranged from 0,849 - 1,081Gy. Thus, the estimative encompassed known absorbed dose the three individuals in confidence interval of 95%. These preliminary results seems to demonstrate that dicentric dose-response curves and dicentrics plus rings established by CRCN-NE / CNEN are valid for dose estimation in exposed individuals. This validation will continue with samples from different individuals at different doses

  4. Radiocesium and polonium in seals from the Baltic Sea. A preliminary study

    International Nuclear Information System (INIS)

    Holm, E.; Leisvik, M.

    2002-01-01

    137 Cs and 210 Po in muscle, liver and kidney from 5 seals from the Baltic Sea have been studied. Assuming that the seals consume 5% of their own body weight each day and by using previously obtained data for the doses in fish, the biological half time has been estimated to 20 days for Cesium and 35 days for Polonium. The maximum yearly doses are calculated to 76 μGy from 137 CS to muscle and 3 500 μGy to kidneys from 210 Po. These data are very preliminary, the number of individuals being so small, and it is difficult to estimate how much food other than fish the seals consume. Furthermore only few data for radioactive concentrations in whole fish exist, which especially impacts the results for Polonium. (LN)

  5. Regulatory Forum Opinion Piece*: Retrospective Evaluation of Doses in the 26-week Tg.rasH2 Mice Carcinogenicity Studies: Recommendation to Eliminate High Doses at Maximum Tolerated Dose (MTD) in Future Studies.

    Science.gov (United States)

    Paranjpe, Madhav G; Denton, Melissa D; Vidmar, Tom J; Elbekai, Reem H

    2015-07-01

    High doses in Tg.rasH2 carcinogenicity studies are usually set at the maximum tolerated dose (MTD), although this dose selection strategy has not been critically evaluated. We analyzed the body weight gains (BWGs), mortality, and tumor response in control and treated groups of 29 Tg.rasH2 studies conducted at BioReliance. Based on our analysis, it is evident that the MTD was exceeded at the high and/or mid-doses in several studies. The incidence of tumors in high doses was lower when compared to the low and mid-doses of both sexes. Thus, we recommend that the high dose in male mice should not exceed one-half of the estimated MTD (EMTD), as it is currently chosen, and the next dose should be one-fourth of the EMTD. Because females were less sensitive to decrements in BWG, the high dose in female mice should not exceed two-third of EMTD and the next dose group should be one-third of EMTD. If needed, a third dose group should be set at one-eighth EMTD in males and one-sixth EMTD in females. In addition, for compounds that do not show toxicity in the range finding studies, a limit dose should be applied for the 26-week carcinogenicity studies. © 2014 by The Author(s).

  6. Phase I dose-finding study of sorafenib with FOLFOX4 as first-line treatment in patients with unresectable locally advanced or metastatic gastric cancer.

    Science.gov (United States)

    Chi, Yihebali; Yang, Jianliang; Yang, Sheng; Sun, Yongkun; Jia, Bo; Shi, Yuankai

    2015-06-01

    To determine the maximum tolerated dose (MTD), dose-limiting toxicity (DLT) and efficacy of sorafenib in combination with FOLFOX4 (oxaliplatin/leucovorin (LV)/5-fluorouracil) as first-line treatment for advanced gastric cancer, we performed a phase I dose-finding study in nine evaluable patients with unresectable locally advanced or metastatic gastric cancer or gastroesophageal junction adenocarcinoma. According to modified Fibonacci method, the design of this study was to guide elevation of the sorafenib dosage to the next level (from 200 mg twice daily to 400 mg twice daily and then, if tolerated, 600 mg twice daily). If the patient achieved complete response (CR), partial response (PR) or stable disease (SD) after eight cycles of treatment, combination chemotherapy was scheduled to be discontinued and sorafenib monotherapy continued at the original dose until either disease progression or unacceptable toxicity. In sorafenib 200 mg twice daily group, DLT was observed in 1 of 6 patients, and in 400 mg twice daily group, it was observed in 2 of 3 patients. Seven of 9 (77.8%) evaluable patients achieved PR, with a median overall survival (OS) of 11.8 [95% confidence interval (CI): 8.9-14.7] months. Common adverse effects include hand-foot syndrome, leukopenia, neutropenia, anorexia, and nausea. Twice-daily dosing of sorafenib 200 mg in combination with FOLFOX4 was proven effective and safe for the treatment of advanced gastric cancer, and could be an appropriate dosage for subsequent phase II clinical studies.

  7. Regulatory T Cell Responses in Participants with Type 1 Diabetes after a Single Dose of Interleukin-2: A Non-Randomised, Open Label, Adaptive Dose-Finding Trial

    Science.gov (United States)

    Todd, John A.; Porter, Linsey; Smyth, Deborah J.; Rainbow, Daniel B.; Ferreira, Ricardo C.; Yang, Jennie H.; Bell, Charles J. M.; Schuilenburg, Helen; Challis, Ben; Clarke, Pamela; Coleman, Gillian; Dawson, Sarah; Goymer, Donna; Kennet, Jane; Brown, Judy; Greatorex, Jane; Goodfellow, Ian; Evans, Mark; Mander, Adrian P.; Bond, Simon; Wicker, Linda S.

    2016-01-01

    Background Interleukin-2 (IL-2) has an essential role in the expansion and function of CD4+ regulatory T cells (Tregs). Tregs reduce tissue damage by limiting the immune response following infection and regulate autoreactive CD4+ effector T cells (Teffs) to prevent autoimmune diseases, such as type 1 diabetes (T1D). Genetic susceptibility to T1D causes alterations in the IL-2 pathway, a finding that supports Tregs as a cellular therapeutic target. Aldesleukin (Proleukin; recombinant human IL-2), which is administered at high doses to activate the immune system in cancer immunotherapy, is now being repositioned to treat inflammatory and autoimmune disorders at lower doses by targeting Tregs. Methods and Findings To define the aldesleukin dose response for Tregs and to find doses that increase Tregs physiologically for treatment of T1D, a statistical and systematic approach was taken by analysing the pharmacokinetics and pharmacodynamics of single doses of subcutaneous aldesleukin in the Adaptive Study of IL-2 Dose on Regulatory T Cells in Type 1 Diabetes (DILT1D), a single centre, non-randomised, open label, adaptive dose-finding trial with 40 adult participants with recently diagnosed T1D. The primary endpoint was the maximum percentage increase in Tregs (defined as CD3+CD4+CD25highCD127low) from the baseline frequency in each participant measured over the 7 d following treatment. There was an initial learning phase with five pairs of participants, each pair receiving one of five pre-assigned single doses from 0.04 × 106 to 1.5 × 106 IU/m2, in order to model the dose-response curve. Results from each participant were then incorporated into interim statistical modelling to target the two doses most likely to induce 10% and 20% increases in Treg frequencies. Primary analysis of the evaluable population (n = 39) found that the optimal doses of aldesleukin to induce 10% and 20% increases in Tregs were 0.101 × 106 IU/m2 (standard error [SE] = 0.078, 95% CI = −0

  8. Corporate Social Disclosures in Southeast Asia: A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Juniati Gunawan

    2012-12-01

    Full Text Available The issue of Corporate Social Disclosure (CSD has been growing remarkably both in business and academic world.  Inevitably, this topic is also exposed in Southeast Asia, a big region that plays important role in global economic issue. Applying a content analysis method, this paper aims to provide preliminary findings in CSD practices throughout the companies‟ annual reports in 2007 and 2008 for countries located in Southeast Asia.  Samples were selected for listed and unlisted various type of industries, based on the information availability internet searching. The sample collection and the subjectivity during the content analysis process are the limitations in conducting this study. In general, the results show that „human resources‟ are the main information disclosed, while in contrast, „energy‟ is the main least issue disclosed in the annual reports.  However, the findings need to be interpreted with considerations since there are limited in samples. Basically, the outcomes support the major prior studies and enhancing the discussion of CSD conducting in developing countries, while at the same time describing some countries which obtained very limited in exposures. To respond the vast increasing issues of CSD practice, this preliminary study has provided a basis to see the role of every country in CSR reporting and how they could support the sustainability development globally.

  9. Optimum dose of 2-hydroxyethyl methacrylate based bonding material on pulp cells toxicity

    OpenAIRE

    Saraswati, Widya

    2010-01-01

    Background: 2-hydroxyethyl methacrylate (HEMA), one type of resins commonly used as bonding base material, is commonly used due to its advantageous chemical characteristics. Several preliminary studies indicated that resin is a material capable to induce damage in dentin-pulp complex. It is necessary to perform further investigation related with its biological safety for hard and soft tissues in oral cavity. Purpose: The author performed an in vitro test to find optimum dose of HEMA resin mon...

  10. Radiation doses in interventional neuroradiology

    International Nuclear Information System (INIS)

    Theodorakou, C.; Butler, P.; Horrocks, J.A.

    2001-01-01

    Patient radiation doses during interventional radiology (IR) procedures may reach the thresholds for radiation-induced skin and eye lens injuries. This study investigates the radiation doses received by patients undergoing cerebral embolization. Measurements were conducted using thermoluminescent dosimeters. Radiotherapy verification films were used in order to visualise the radiation field. For each procedure the fluoroscopic and digital dose-area product, the fluoroscopic time, the total number of acquired images and entrance-skin dose calculated by the angiographic unit were recorded. In this paper, the skin, eye and thyroid glands doses on a sample of patients are presented. From a preliminary study of 13 patients having undergone cerebral embolization, it was deduced that six of them have received a dose above 1 Gy. Detailed dose data from patients undergoing IR procedures will be collected in the future with the aim of developing a model to allow estimation of the dose prior to the procedure as well as to look at techniques of dose reduction. (author)

  11. Robotic path-finding in inverse treatment planning for stereotactic radiosurgery with continuous dose delivery

    Energy Technology Data Exchange (ETDEWEB)

    Vandewouw, Marlee M., E-mail: marleev@mie.utoronto.ca; Aleman, Dionne M. [Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Ontario M5S 3G8 (Canada); Jaffray, David A. [Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario M5G 2M9 (Canada)

    2016-08-15

    Purpose: Continuous dose delivery in radiation therapy treatments has been shown to decrease total treatment time while improving the dose conformity and distribution homogeneity over the conventional step-and-shoot approach. The authors develop an inverse treatment planning method for Gamma Knife® Perfexion™ that continuously delivers dose along a path in the target. Methods: The authors’ method is comprised of two steps: find a path within the target, then solve a mixed integer optimization model to find the optimal collimator configurations and durations along the selected path. Robotic path-finding techniques, specifically, simultaneous localization and mapping (SLAM) using an extended Kalman filter, are used to obtain a path that travels sufficiently close to selected isocentre locations. SLAM is novelly extended to explore a 3D, discrete environment, which is the target discretized into voxels. Further novel extensions are incorporated into the steering mechanism to account for target geometry. Results: The SLAM method was tested on seven clinical cases and compared to clinical, Hamiltonian path continuous delivery, and inverse step-and-shoot treatment plans. The SLAM approach improved dose metrics compared to the clinical plans and Hamiltonian path continuous delivery plans. Beam-on times improved over clinical plans, and had mixed performance compared to Hamiltonian path continuous plans. The SLAM method is also shown to be robust to path selection inaccuracies, isocentre selection, and dose distribution. Conclusions: The SLAM method for continuous delivery provides decreased total treatment time and increased treatment quality compared to both clinical and inverse step-and-shoot plans, and outperforms existing path methods in treatment quality. It also accounts for uncertainty in treatment planning by accommodating inaccuracies.

  12. Robotic path-finding in inverse treatment planning for stereotactic radiosurgery with continuous dose delivery

    International Nuclear Information System (INIS)

    Vandewouw, Marlee M.; Aleman, Dionne M.; Jaffray, David A.

    2016-01-01

    Purpose: Continuous dose delivery in radiation therapy treatments has been shown to decrease total treatment time while improving the dose conformity and distribution homogeneity over the conventional step-and-shoot approach. The authors develop an inverse treatment planning method for Gamma Knife® Perfexion™ that continuously delivers dose along a path in the target. Methods: The authors’ method is comprised of two steps: find a path within the target, then solve a mixed integer optimization model to find the optimal collimator configurations and durations along the selected path. Robotic path-finding techniques, specifically, simultaneous localization and mapping (SLAM) using an extended Kalman filter, are used to obtain a path that travels sufficiently close to selected isocentre locations. SLAM is novelly extended to explore a 3D, discrete environment, which is the target discretized into voxels. Further novel extensions are incorporated into the steering mechanism to account for target geometry. Results: The SLAM method was tested on seven clinical cases and compared to clinical, Hamiltonian path continuous delivery, and inverse step-and-shoot treatment plans. The SLAM approach improved dose metrics compared to the clinical plans and Hamiltonian path continuous delivery plans. Beam-on times improved over clinical plans, and had mixed performance compared to Hamiltonian path continuous plans. The SLAM method is also shown to be robust to path selection inaccuracies, isocentre selection, and dose distribution. Conclusions: The SLAM method for continuous delivery provides decreased total treatment time and increased treatment quality compared to both clinical and inverse step-and-shoot plans, and outperforms existing path methods in treatment quality. It also accounts for uncertainty in treatment planning by accommodating inaccuracies.

  13. A preliminary assessment of individual doses in the environs of Berkeley, Gloucestershire, following the Chernobyl nuclear reactor accident

    International Nuclear Information System (INIS)

    Nair, S.; Darley, P.J.

    1986-06-01

    A preliminary assessment has been made of the individual doses to critical group members of the public in the environs of Berkeley arising from fallout resulting from the Chernobyl accident. The assessment was based on measurements of airborne radionuclide concentrations, ground deposition and nuclide concentrations in rainwater, tapwater, grass, milk and green vegetables. The committed effective dose-equivalent was found to be as follows:- Adult - 200 μSv, 1 year old child - 500 μSv, the 10 year old child receiving a dose intermediate between these two values. The estimate accounts only for the nuclides measured and the specific exposure routes considered namely ingestion of milk and vegetables, inhalation and external exposure. However, it is believed that the inclusion of a range of other nuclides of potential significance, which may have been present but not measured, and potential intakes from additional routes is unlikely to increase the above estimates by more than a factor of 2. (author)

  14. Diffusion-weighted MR imaging of cystic lesions of neurocysticercosis: a preliminary study

    International Nuclear Information System (INIS)

    Raffin, Luciana S.; Bacheschi, Luiz A.; Machado, Luis R.; Nobrega, Jose P.S.; Coelho, Christina; Leite, Claudia C.

    2001-01-01

    Neurocysticercosis is an endemic disease in some developing countries. It has pleomorfic clinical and imaging findings, which are variable from patient to patient. In this preliminary note, we studied the magnetic resonance diffusion-weighted images of sixteen patients presenting with cystic lesions of this disease diagnosed by clinical and laboratorial findings. All the lesions had hypointense signal and the similar apparent diffusion coefficient values as the cerebrospinal fluid. (author)

  15. Narcissism and consumer behaviour: a review and preliminary findings

    Science.gov (United States)

    Cisek, Sylwia Z.; Sedikides, Constantine; Hart, Claire M.; Godwin, Hayward J.; Benson, Valerie; Liversedge, Simon P.

    2014-01-01

    We review the literature on the relation between narcissism and consumer behavior. Consumer behavior is sometimes guided by self-related motives (e.g., self-enhancement) rather than by rational economic considerations. Narcissism is a case in point. This personality trait reflects a self-centered, self-aggrandizing, dominant, and manipulative orientation. Narcissists are characterized by exhibitionism and vanity, and they see themselves as superior and entitled. To validate their grandiose self-image, narcissists purchase high-prestige products (i.e., luxurious, exclusive, flashy), show greater interest in the symbolic than utilitarian value of products, and distinguish themselves positively from others via their materialistic possessions. Our review lays the foundation for a novel methodological approach in which we explore how narcissism influences eye movement behavior during consumer decision-making. We conclude with a description of our experimental paradigm and report preliminary results. Our findings will provide insight into the mechanisms underlying narcissists’ conspicuous purchases. They will also likely have implications for theories of personality, consumer behavior, marketing, advertising, and visual cognition. PMID:24711797

  16. Narcissism and consumer behaviour: a review and preliminary findings.

    Science.gov (United States)

    Cisek, Sylwia Z; Sedikides, Constantine; Hart, Claire M; Godwin, Hayward J; Benson, Valerie; Liversedge, Simon P

    2014-01-01

    We review the literature on the relation between narcissism and consumer behavior. Consumer behavior is sometimes guided by self-related motives (e.g., self-enhancement) rather than by rational economic considerations. Narcissism is a case in point. This personality trait reflects a self-centered, self-aggrandizing, dominant, and manipulative orientation. Narcissists are characterized by exhibitionism and vanity, and they see themselves as superior and entitled. To validate their grandiose self-image, narcissists purchase high-prestige products (i.e., luxurious, exclusive, flashy), show greater interest in the symbolic than utilitarian value of products, and distinguish themselves positively from others via their materialistic possessions. Our review lays the foundation for a novel methodological approach in which we explore how narcissism influences eye movement behavior during consumer decision-making. We conclude with a description of our experimental paradigm and report preliminary results. Our findings will provide insight into the mechanisms underlying narcissists' conspicuous purchases. They will also likely have implications for theories of personality, consumer behavior, marketing, advertising, and visual cognition.

  17. Narcissism and Consumer Behaviour: A Review and Preliminary Findings

    Directory of Open Access Journals (Sweden)

    Sylwia Z Cisek

    2014-03-01

    Full Text Available We review the literature on the relation between narcissism and consumer behaviour. Consumer behaviour is sometimes guided by self-related motives (e.g., self-enhancement rather than by rational economic considerations. Narcissism is a case in point. This personality trait reflects a self-centred, self-aggrandizing, dominant, and manipulative orientation. Narcissists are characterised by exhibitionism and vanity, and they see themselves as superior and entitled. To validate their grandiose self-image, narcissists purchase high-prestige products (i.e., luxurious, exclusive, flashy, show greater interest in the symbolic than utilitarian value of products, and distinguish themselves positively from others via their materialistic possessions. Our review lays the foundation for a novel methodological approach in which we explore how narcissism influences eye movement behaviour during consumer decision-making. We conclude with a description of our experimental paradigm and report preliminary results. Our findings will provide insight into the mechanisms underlying narcissists’ conspicuous purchases. They will also likely have implications for theories of personality, consumer behaviour, marketing, advertising, and visual cognition.

  18. Teflon pastille use in high dose dosimetry; Utilizacao de pastilhas de teflon em dosimetria de doses altas

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Maria Ines [Associacao Educacional Nove de Julho (UNINOVE), Sao Paulo, SP (Brazil); Caldas, Linda V.E., E-mail: miteixeira@ipen.b, E-mail: lcaldas@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-10-26

    This paper study the Teflon, which is used as aglomerant in the confection of dosimetric pastilles, for the viabilization of this material as high dose dosimeter. This paper used the OSL technique for the characterization of dosimetric properties of Teflon. The doses-response curve has been obtained for {sup 60}Co radiation between 100 Gy and 50 kGy, and the OSL answer reproducibility. The preliminary results shown that the Teflon is a material which can be used for high dose dosimetry

  19. Tg.rasH2 Mice and not CByB6F1 Mice Should Be Used for 28-Day Dose Range Finding Studies Prior to 26-Week Tg.rasH2 Carcinogenicity Studies.

    Science.gov (United States)

    Paranjpe, Madhav G; Belich, Jessica; Vidmar, Tom J; Elbekai, Reem H; McKeon, Marie; Brown, Caren

    Our recent retrospective analysis of data, collected from 29 Tg.rasH2 mouse carcinogenicity studies, determined how successful the strategy of choosing the high dose for the 26-week studies was based on the estimated maximum tolerated dose (EMTD) derived from earlier 28-day dose range finding (DRF) studies conducted in CByB6F1 mice. Our analysis demonstrated that the high doses applied at EMTD in the 26-week Tg.rasH2 studies failed to detect carcinogenic effects. To investigate why the dose selection process failed in the 26-week carcinogenicity studies, the initial body weights, terminal body weights, body weight gains, food consumption, and mortality from the first 4 weeks of 26-week studies with Tg.rasH2 mice were compared with 28-day DRF studies conducted with CByB6F1 mice. Both the 26-week and the earlier respective 28-day studies were conducted with the exact same vehicle, test article, and similar dose levels. The analysis of our results further emphasizes that the EMTD and subsequent lower doses, determined on the basis of the 28-day studies in CByB6F1 mice, may not be an accurate strategy for selecting appropriate dose levels for the 26-week carcinogenicity studies in Tg.rasH2 mice. Based on the analysis presented in this article, we propose that the Tg.rasH2 mice and not the CByB6F1 mice should be used in future DRF studies. The Tg.rasH2 mice demonstrate more toxicity than the CByB6F1 mice, possibly because of their smaller size compared to CByB6F1 mice. Also, the Tg.rasH2 males appear to be more sensitive than the female Tg.rasH2 mice.

  20. Preliminary liver dose estimation in the new facility for biomedical applications at the RA-3 reactor

    International Nuclear Information System (INIS)

    Gadan, M.; Crawley, V.; Thorp, S.; Miller, M.

    2009-01-01

    As a part of the project concerning the irradiation of a section of the human liver left lobe, a preliminary estimation of the expected dose was performed. To obtain proper input values for the calculation, neutron flux and gamma dose rate characterization were carried out using adequate portions of cow or pig liver covered with demineralized water simulating the preservation solution. Irradiations were done inside a container specially designed to fulfill temperature preservation of the organ and a reproducible irradiation position (which will be of importance for future planification purposes). Implantable rhodium based self-powered neutron detectors were developed to obtain neutron flux profiles both external and internal. Implantation of SPND was done along the central longitudinal axis of the samples, where lowest flux is expected. Gamma dose rate was obtained using a neutron shielded graphite ionization chamber moved along external surfaces of the samples. The internal neutron profile resulted uniform enough to allow for a single and static irradiation of the liver. For dose estimation, irradiation condition was set in order to obtain a maximum of 15 Gy-eq in healthy tissue. Additionally, literature reported boron concentrations of 47 ppm in tumor and 8 ppm in healthy tissue and a more conservative relationship (30/10 ppm) were used. To make a conservative estimation of the dose the following considerations were done: (i).Minimum measured neutron flux inside the sample (∼5x10 9 n cm -2 s -1 ) was considered to calculate dose in tumor. (ii).Maximum measured neutron flux (considering both internal as external profiles) was used to calculate dose in healthy tissue (∼8.7x10 9 n cm -2 s -1 ). (iii).Maximum measured gamma dose rate (∼13.5 Gy h -1 ) was considered for both tumor and healthy tissue. Tumor tissue dose was ∼69 Gy-eq for 47 ppm of 10 B and ∼42 Gy-eq for 30 ppm, for a maximum dose of 15 Gy-eq in healthy tissue. As can be seen from these results

  1. Preliminary study of soil permeability properties using principal component analysis

    Science.gov (United States)

    Yulianti, M.; Sudriani, Y.; Rustini, H. A.

    2018-02-01

    Soil permeability measurement is undoubtedly important in carrying out soil-water research such as rainfall-runoff modelling, irrigation water distribution systems, etc. It is also known that acquiring reliable soil permeability data is rather laborious, time-consuming, and costly. Therefore, it is desirable to develop the prediction model. Several studies of empirical equations for predicting permeability have been undertaken by many researchers. These studies derived the models from areas which soil characteristics are different from Indonesian soil, which suggest a possibility that these permeability models are site-specific. The purpose of this study is to identify which soil parameters correspond strongly to soil permeability and propose a preliminary model for permeability prediction. Principal component analysis (PCA) was applied to 16 parameters analysed from 37 sites consist of 91 samples obtained from Batanghari Watershed. Findings indicated five variables that have strong correlation with soil permeability, and we recommend a preliminary permeability model, which is potential for further development.

  2. Preliminary effects of pagoclone, a partial GABAA agonist, on neuropsychological performance

    Directory of Open Access Journals (Sweden)

    Angela F Caveney

    2008-03-01

    Full Text Available Angela F Caveney1, Bruno Giordani1, George M Haig21Department of Psychiatry, University of Michigan, Ann Arbor, MI, USA; 2Neurosciences Development, Abbott Laboratories, Abbott Park, IL, USAAbstract: Pagoclone is a novel cyclopyrrolone that acts as a partial GABAA receptor agonist. Preclinical studies suggest that pagoclone may have clinical utility as an anxiolytic agent, as well as a reduced incidence of side-effects. The present study was conducted to determine whether pagoclone would affect healthy individuals’ performances on neuropsychological measures as a function of dose within the projected therapeutic range. Twelve healthy adult subjects were randomly assigned to dosage groups in a 3-way crossover study. Participants were administered neuropsychological measures six hours following dosing on Day 1 and Day 6 of administration of the drug. Dose effects were noted on measures of alertness, learning, and memory and movement time. Significant effects were also noted on measures of alertness, learning and memory, information processing and psychomotor speed. Overall, the results of this small, preliminary study do not support a finding of behavioral toxicity for these doses of pagoclone. Rather, a pattern was found of transient and mild negative effects on learning and memory scores at the highest dose administered, though these changes were small and no longer evident by the sixth day of use.Keywords: pagoclone, cyclopyrrolone, neuropsychological, memory, generalized anxiety disorder

  3. Preliminary study on the measurement of background radiation dose at Antarctica during 32nd expedition

    International Nuclear Information System (INIS)

    Bakshi, A.K.; Pal, Rupali; Chougaonkar, M.P.; Dhar, Ajay

    2013-01-01

    A significant proportion (10%) of the natural background radiation is of cosmic origin. Cosmic ray consists of gamma, protons, electrons, pions, muons, neutrons and low Z nuclei. Due to the geomagnetic effect, cosmic radiation levels at poles are higher. As a consequence, personnel working in Antarctica (or Arctic) are subjected to high level of cosmic radiation. The present study gives the details of the estimation of background radiation (neutrons, gamma and electrons) dose rate around the Indian station at Antarctica named 'Bharati' measured during 32 nd Indian scientific expedition to Antarctica (32 nd INSEA). The measurement was carried out by passive dosimeters such as TLDs and CR-39 and active dosimeter such as RadEye G portable gamma survey meter. Gamma and electron components were measured using TLDs and survey meter, whereas CR-39 SSNTDs and neutron sensitive TLDs were used for neutron measurements. These detectors were deployed at few selected locations around Bharati station for about 2½ months during summer expedition. The neutron detectors used in the study were pre-calibrated with 241 Am-Be fast/thermal neutron source. The fast neutron dose rate measured based on CR-39 detector was found to about 140-420 nSv/h. The gamma dose rate evaluated by TLDs/survey meter are in the range of 290-400 nSv/h. (author)

  4. Peritoneal Nebulization of Ropivacaine during Laparoscopic Cholecystectomy: Dose Finding and Pharmacokinetic Study

    Directory of Open Access Journals (Sweden)

    Massimo Allegri

    2017-01-01

    Full Text Available Background. Intraperitoneal nebulization of ropivacaine reduces postoperative pain and morphine consumption after laparoscopic surgery. The aim of this multicenter double-blind randomized controlled trial was to assess the efficacy of different doses and dose-related absorption of ropivacaine when nebulized in the peritoneal cavity during laparoscopic cholecystectomy. Methods. Patients were randomized to receive 50, 100, or 150 mg of ropivacaine 1% by peritoneal nebulization through a nebulizer. Morphine consumption, pain intensity in the abdomen, wound and shoulder, time to unassisted ambulation, discharge time, and adverse effects were collected during the first 48 hours after surgery. The pharmacokinetics of ropivacaine was evaluated using high performance liquid chromatography. Results. Nebulization of 50 mg of ropivacaine had the same effect of 100 or 150 mg in terms of postoperative morphine consumption, shoulder pain, postoperative nausea and vomiting, activity resumption, and hospital discharge timing (>0.05. Plasma concentrations did not reach toxic levels in any patient, and no significant differences were observed between groups (P>0.05. Conclusions. There is no enhancement in analgesic efficacy with higher doses of nebulized ropivacaine during laparoscopic cholecystectomy. When administered with a microvibration-based aerosol humidification system, the pharmacokinetics of ropivacaine is constant and maintains an adequate safety profile for each dosage tested.

  5. Optimizing adaptive design for Phase 2 dose-finding trials incorporating long-term success and financial considerations: A case study for neuropathic pain.

    Science.gov (United States)

    Gao, Jingjing; Nangia, Narinder; Jia, Jia; Bolognese, James; Bhattacharyya, Jaydeep; Patel, Nitin

    2017-06-01

    In this paper, we propose an adaptive randomization design for Phase 2 dose-finding trials to optimize Net Present Value (NPV) for an experimental drug. We replace the traditional fixed sample size design (Patel, et al., 2012) by this new design to see if NPV from the original paper can be improved. Comparison of the proposed design to the previous design is made via simulations using a hypothetical example based on a Diabetic Neuropathic Pain Study. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Sugammadex and neostigmine dose-finding study for reversal of residual neuromuscular block at a train-of-four ratio of 0.2 (SUNDRO20)†,.

    Science.gov (United States)

    Kaufhold, N; Schaller, S J; Stäuble, C G; Baumüller, E; Ulm, K; Blobner, M; Fink, H

    2016-02-01

    The aim of this dose-finding study was to evaluate the dose-response relationship of sugammadex and neostigmine to reverse a commonly observed level of incomplete recovery from rocuronium-induced neuromuscular block, that is, a train-of-four ratio (TOFR) ≥0.2. Ninety-nine anaesthetized patients received rocuronium 0.6 mg kg(-1) i.v. for tracheal intubation and, if necessary, incremental doses of 0.1-0.2 mg kg(-1). Neuromuscular monitoring was performed by calibrated electromyography. Once the TOFR recovered to 0.2, patients were randomized to receive sugammadex (0.25, 0.5, 0.75, 1.0, or 1.25 mg kg(-1) i.v.), neostigmine (10, 25, 40, 55, or 70 µg kg(-1) i.v.), or saline (n=9 per group). Primary and secondary end points were the doses necessary to restore neuromuscular function to a TOFR≥0.9 with an upper limit of 5 and 10 min for 95% of patients, respectively. Neostigmine was not able to fulfil the end points. Based on the best-fitting model, the sugammadex dose estimation for recovery to a TOFR≥0.9 for 95% of patients within 5 and 10 min was 0.49 and 0.26 mg kg(-1), respectively. A residual neuromuscular block of a TOFR of 0.2 cannot be reversed reliably with neostigmine within 10 min. In the conditions studied, substantially lower doses of sugammadex than the approved dose of 2.0 mg kg(-1) may be sufficient to reverse residual rocuronium-induced neuromuscular block at a recovery of TOFR≥0.2. NCT01006720. © The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Life span studies on mice exposed to heavy charged particles or photons: preliminary results

    International Nuclear Information System (INIS)

    Ainsworth, E.J.

    1980-01-01

    This chapter summarizes the results currently available where dose-dependent mortality is compared among the single cohort that received fractionated doses of carbon ions and the first replicate that received single doses. At this time, 17% mortality has occurred in both groups and had enhanced life shortening been produced by fractionation of the carbon ion dose, somewhat higher mortality might be expected. Cautious interpretation of these preliminary results is necessary, but the mortality data available at this time provides no evidence for enhancement by dose fractionation with carbon ions. In sum, at this time, it appears the Q factor used for fission spectrum neutrons could be conservative if it were used for assessment of risk following exposure to 400 MeV carbon ions

  8. Preliminary study of the specific endothelin a receptor antagonist zibotentan in combination with docetaxel in patients with metastatic castration-resistant prostate cancer.

    Science.gov (United States)

    Trump, Donald L; Payne, Heather; Miller, Kurt; de Bono, Johann S; Stephenson, Joe; Burris, Howard A; Nathan, Faith; Taboada, Maria; Morris, Thomas; Hubner, Andreas

    2011-09-01

    This two-part study assessed the safety and tolerability of combined treatment with zibotentan (ZD4054), a specific endothelin A receptor antagonist, plus docetaxel in patients with metastatic castration-resistant prostate cancer. Part A was an open-label, dose-finding phase to determine the safety and toxicity profile of zibotentan in combination with docetaxel. Patients received once-daily oral zibotentan 10 mg (initial cohort) or 15 mg in combination with docetaxel 75 mg/m(2) (administered on day 1 of each 21-day cycle) for up to 10 cycles. Part B was a double-blind phase which evaluated the safety and preliminary activity of zibotentan plus docetaxel. Patients were randomized 2:1 to receive zibotentan (at the highest tolerated dose identified in part A) plus docetaxel or placebo plus docetaxel. Six patients were enrolled in part A (n  = 3, zibotentan 10 mg; n = 3, zibotentan 15 mg). No dose-limiting toxicity was observed, thus zibotentan 15 mg in combination with docetaxel was evaluated in part B (n = 20, zibotentan plus docetaxel; n = 11, placebo plus docetaxel). CTCAE grade ≥3, most commonly neutropenia or leucopenia, were reported in 10 (50%) and nine (82%) patients in the zibotentan and placebo groups, respectively. One (17%) patient receiving placebo achieved complete response, two (22%) patients receiving zibotentan achieved partial response and stable disease occurred in six (67%) and three (50%) patients receiving zibotentan and placebo, respectively. The tolerability of zibotentan plus docetaxel was consistent with the known profiles of each drug. Sufficient preliminary activity was seen with this combination to merit continued development. Copyright © 2011 Wiley-Liss, Inc.

  9. Cytogenetics dosimetry: dose-response curve for low doses of X-ray; Dosimetria citogenetica: curva dosis-respuesta para bajas dosis de rayos-X

    Energy Technology Data Exchange (ETDEWEB)

    Lara, Virginia E. Noval; Pineda Bolivar, William R.; Riano, Victor M. Pabon, E-mail: venovall.15@hotmail.com, E-mail: wrpineda@misena.edu.co, E-mail: vmpabonr@udistrital.edu.co [Universidad Distrital Francisco Jose de Caldas (UD), Bogota (Colombia). Grupo de Investigacion en Ciencia y Tecnologia Nuclear; Ureana, Cecilia Crane, E-mail: cecicrane@yahoo.com [Instituto Nacional de Salud (INS), Bogota (Colombia). Laboratorio de Genetica

    2013-07-01

    The purpose of this study was to conduct a preliminary study for the standardization in the future, the dose-response curve for low doses of X-rays, through the analysis of in vitro cultures of peripheral blood samples of 3 men and 3 women occupationally not exposed to artificial sources of ionizing radiation, age 18-40 years, where possible nonsmokers.

  10. Phase 1 of the Hanford Environmental Dose Reconstruction Project

    International Nuclear Information System (INIS)

    1991-08-01

    The work described in this report was prompted by the public's concern about potential effect from the radioactive materials released from the Hanford Site. The Hanford Environmental Dose Reconstruction (HEDR) Project was established to estimate radiation dose the public might have received from the Hanford Site since 1944, when facilities began operating. Phase 1 of the HEDR Project is a ''pilot'' or ''demonstration'' phase. The objectives of this initial phase were to determine whether enough historical information could be found or reconstructed to be used for dose estimation and develop and test conceptual and computational models for calculating credible dose estimates. Preliminary estimates of radiation doses were produced in Phase 1 because they are needed to achieve these objectives. The reader is cautioned that the dose estimates provided in this and other Phase 1 HEDR reports are preliminary. As the HEDR Project continues, the dose estimates will change for at least three reasons: more complete input information for models will be developed; the models themselves will be refined; and the size and shape of the geographic study area will change. This is one of three draft reports that summarize the first phase of the four-phased HEDR Project. This, the Summary Report, is directed to readers who want a general understanding of the Phase 1 work and preliminary dose estimates. The two other reports -- the Air Pathway Report and the Columbia River Pathway Report -- are for readers who understand the radiation dose assessment process and want to see more technical detail. Detailed descriptions of the dose reconstruction process are available in more than 20 supporting reports listed in Appendix A. 32 refs., 46 figs

  11. Prevention of laryngospasm with rocuronium in cats: a dose-finding study.

    Science.gov (United States)

    Martin-Flores, Manuel; Sakai, Daniel M; Portela, Diego A; Borlle, Lucia; Campoy, Luis; Gleed, Robin D

    2016-09-01

    To identify the dose of rocuronium that will prevent a laryngeal response to water spraying of the glottis in anesthetized cats. Randomized crossover study. Eight healthy, adult, short-haired cats, aged 1-4 years, weighing 3.2-6.0 kg. Each cat was anesthetized four times and administered one of four doses of rocuronium (0.1, 0.2, 0.3 and 0.6 mg kg(-1) ) in random order. The larynx was observed with a video-endoscope inserted through a laryngeal mask airway. Video-clips of the laryngeal response to a sterile water spray (0.2 mL) were obtained at baseline (without rocuronium) and at maximal effect of each treatment. Glottal closure score (0-2), duration of glottal closure, and number of adductive arytenoid movements were obtained from video-clips of laryngeal responses (reproduced in slow motion) at baseline and after treatment. Two observers blinded to treatment allocation scored the vigor of the laryngeal response on a visual analog scale (VAS). The duration of apnea (up to 5 minutes) was recorded for each treatment. Compared with baseline, rocuronium 0.3 mg kg(-1) and 0.6 mg kg(-1) significantly decreased all glottal scores obtained from the videos (all p rocuronium 0.1, 0.2, 0.3 and 0.6 mg kg(-1) , respectively. Rocuronium 0.3 mg kg(-1) and 0.6 mg kg(-1) consistently decreased the completeness and duration of the laryngeal response to water spray, and reduced the number of arytenoid adductive movements in response to that stimulus. However, a laryngeal response was never completely prevented. Rocuronium 0.3 mg kg(-1) may be useful for facilitating tracheal intubation. Positive pressure ventilation must be available for cats administered rocuronium. © 2016 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  12. No-threshold dose-response curves for nongenotoxic chemicals: Findings and applications for risk assessment

    International Nuclear Information System (INIS)

    Sheehan, Daniel M.

    2006-01-01

    We tested the hypothesis that no threshold exists when estradiol acts through the same mechanism as an active endogenous estrogen. A Michaelis-Menten (MM) equation accounting for response saturation, background effects, and endogenous estrogen level fit a turtle sex-reversal data set with no threshold and estimated the endogenous dose. Additionally, 31 diverse literature dose-response data sets were analyzed by adding a term for nonhormonal background; good fits were obtained but endogenous dose estimations were not significant due to low resolving power. No thresholds were observed. Data sets were plotted using a normalized MM equation; all 178 data points were accommodated on a single graph. Response rates from ∼1% to >95% were well fit. The findings contradict the threshold assumption and low-dose safety. Calculating risk and assuming additivity of effects from multiple chemicals acting through the same mechanism rather than assuming a safe dose for nonthresholded curves is appropriate

  13. Establishment of 60Co dose calibration curve using fluorescent in situ hybridization assay technique: Result of preliminary study

    International Nuclear Information System (INIS)

    Rahimah Abdul Rahim; Noriah Jamal; Noraisyah Mohd Yusof; Juliana Mahamad Napiah; Nelly Bo Nai Lee

    2010-01-01

    This study aims at establishing an in-vitro 60 Co dose calibration curve using Fluorescent In-Situ Hybridization assay technique for the Malaysian National Bio dosimetry Laboratory. Blood samples collected from a female healthy donor were irradiated with several doses of 60 Co radiation. Following culturing of lymphocytes, microscopic slides are prepared, denatured and hybridized. The frequencies of translocation are estimated in the metaphases. A calibration curve was then generated using a regression technique. It shows a good fit to a linear-quadratic model. The results of this study might be useful in estimating absorbed dose for the individual exposed to ionizing radiation retrospectively. This information may be useful as a guide for medical treatment for the assessment of possible health consequences. (author)

  14. Findings of an international study on burnup credit

    International Nuclear Information System (INIS)

    Brady, M.C.; Takano, M.; Okuno, H.; DeHart, M.D.; Nouri, A.

    1996-01-01

    Findings from a four year study by an international benchmarking group in the comparison of computational methods for evaluating burnup credit in criticality safety analyses are presented in this paper. Approximately 20 participants from 11 countries have provided results for most problems. Four detailed benchmark problems for Pressurized Water Reactor (PWR) fuel have been completed and are summarized in this paper. Preliminary results from current work addressing burnup credit for Boiling Water Reactor (BWR) fuel will also be discussed as well as planned activities for additional benchmarks including Mixed-Oxide (MOX) fuels, subcritical benchmarks, international databases, and other activities

  15. Combination chemotherapy with intermittent erlotinib and pemetrexed for pretreated patients with advanced non-small cell lung cancer: a phase I dose-finding study

    International Nuclear Information System (INIS)

    Minami, Seigo; Tachibana, Isao; Komuta, Kiyoshi; Kawase, Ichiro; Kijima, Takashi; Takahashi, Ryo; Kida, Hiroshi; Nakatani, Takeshi; Hamaguchi, Masanari; Takeuchi, Yoshiko; Nagatomo, Izumi; Yamamoto, Suguru

    2012-01-01

    Erlotinib and pemetrexed have been approved for the second-line treatment of non-small cell lung cancer (NSCLC). These two agents have different mechanisms of action. Combined treatment with erlotinib and pemetrexed could potentially augment the antitumor activity of either agent alone. In the present study, we investigated the safety profile of combined administration of the two agents in pretreated NSCLC patients. A phase I dose-finding study (Trial registration: UMIN000002900) was performed in patients with stage III/IV nonsquamous NSCLC whose disease had progressed on or after receiving first-line chemotherapy. Patients received 500 mg/m 2 of pemetrexed intravenously every 21 days and erlotinib (100 mg at Level 1 and 150 mg at Level 2) orally on days 2–16. Twelve patients, nine males and three females, were recruited. Patient characteristics included a median age of 66 years (range, 48–78 years), stage IV disease (nine cases), adenocarcinoma (seven cases) and activating mutation-positives in the epidermal growth factor receptor gene (two cases). Treatment was well-tolerated, and the recommended dose of erlotinib was fixed at 150 mg. Dose-limiting toxicities were experienced in three patients and included: grade 3 elevation of serum alanine aminotransferase, repetitive grade 4 neutropenia that required reduction of the second dose of pemetrexed and grade 3 diarrhea. No patient experienced drug-induced interstitial lung disease. Three patients achieved a partial response and stable disease was maintained in five patients. Combination chemotherapy of intermittent erlotinib with pemetrexed was well-tolerated, with promising efficacy against pretreated advanced nonsquamous NSCLC

  16. 75 FR 17161 - Job Corps: Preliminary Finding of No Significant Impact (FONSI) for the Installation of a Small...

    Science.gov (United States)

    2010-04-05

    ... DEPARTMENT OF LABOR Office of the Secretary Job Corps: Preliminary Finding of No Significant Impact (FONSI) for the Installation of a Small Wind Turbine at the Pine Ridge Job Corps Center Located at... the Pine Ridge Job Corps Center, 15710 Highway 385, Chadron, NE 69337. SUMMARY: Pursuant to the...

  17. A preliminary, controlled investigation of magnesium L-aspartate hydrochloride for illicit cocaine and opiate use in methadone-maintained patients.

    Science.gov (United States)

    Margolin, Arthur; Kantak, Kathleen; Copenhaver, Michael; Avants, S Kelly

    2003-01-01

    Based on pre-clinical studies suggesting that magnesium (Mg) reduces cocaine self-administration and potentiates the antinociceptive effects of morphine, we conducted a preliminary randomized clinical trial investigating Mg for the treatment of illicit cocaine and opiate use. Eighteen methadone-maintained patients who used illicit opiates and cocaine received either Mg (732 mg/day) or placebo for 12 weeks. Overall, findings showed that the percentage of urine screens testing positive for opiates in the Mg group (22.6%) was half that of the placebo group (46.4%), p = .04; the difference was even greater in the "medication compliant" sample (Mg: 16.3%, placebo: 47.9%), p = .02. Cocaine craving was lower in the Mg compared to the placebo group, but there was no difference between groups in cocaine use. These preliminary findings suggest that Mg may have a beneficial effect for reducing illicit opiate use. It is possible that a higher dose of Mg than was used in this study may be needed to decrease cocaine use.

  18. Automated detection of lung nodules in low-dose computed tomography

    International Nuclear Information System (INIS)

    Cascio, D.; Cheran, S.C.; Chincarini, A.; De Nunzio, G.; Delogu, P.; Fantacci, M.E.; Gargano, G.; Gori, I.; Retico, A.; Masala, G.L.; Preite Martinez, A.; Santoro, M.; Spinelli, C.; Tarantino, T.

    2007-01-01

    A computer-aided detection (CAD) system for the identification of pulmonary nodules in low-dose multi-detector computed-tomography (CT) images has been developed in the framework of the MAGIC-5 Italian project. One of the main goals of this project is to build a distributed database of lung CT scans in order to enable automated image analysis through a data and cpu GRID infrastructure. The basic modules of our lung-CAD system, consisting in a 3D dot-enhancement filter for nodule detection and a neural classifier for false-positive finding reduction, are described. The system was designed and tested for both internal and sub-pleural nodules. The database used in this study consists of 17 low-dose CT scans reconstructed with thin slice thickness (∝300 slices/scan). The preliminary results are shown in terms of the FROC analysis reporting a good sensitivity (85% range) for both internal and sub-pleural nodules at an acceptable level of false positive findings (1-9 FP/scan); the sensitivity value remains very high (75% range) even at 1-6 FP/scan. (orig.)

  19. Radiation doses from computed tomography in Australia

    International Nuclear Information System (INIS)

    Thomson, J.E.M.; Tingey, D.R.C.

    1996-01-01

    Recent surveys in the UK and New Zealand have shown that although the number of CT examinations small compared to conventional Radiology, CT contributes about 20% to the overall dose from diagnostic radiology. In view of these findings and the rapid increase in the number of CT facilities in recent years, a survey of the number of facilities, frequency of examination, techniques and patient doses has been performed. Australia, with 329 units is well endowed with CT equipment compared to European Countries and New Zealand. For many examinations a wide range was found in the number of slices and slice widths used and this led to a large spread in the corresponding doses. Assuming the practices of the non-responders are statistically similar to those who responded, some preliminary estimates of population doses can be made. There could be as many as 1.1 million CT examinations each year in Australia resulting in a per capur effectie dose of 0.36 mSv. Although the results of this survey are still subject to some refinement, they indicate that CT is a major, and possibly the dominant, contributor to doses from diagnostic radiology in Australia. (author)

  20. Dose conversion of radon exposure according to new epidemiological findings

    International Nuclear Information System (INIS)

    Tomasek, L.; Rogel, A.; Laurier, D.; Tirmarche, M.

    2008-01-01

    In 1993, ICRP-65 recommended that dose conversion of radon exposure should be based on the comparison of detriments between radon exposure and effective dose. The lifetime detriment from the radon exposure was projected according to the epidemiological studies of uranium miners then available. The projection model (GSF) was multiplicative with temporal and age-at-exposure modification. Since 1993, new studies of uranium miners have appeared and many original studies were updated. In addition, projections of the risk have been improved by including further modifying factors as for instance in BEIR VI. New analyses were completed in the Czech and French studies of uranium miners with accurate estimates of exposures based on extensive radon measurements. The resulting estimates of excess absolute lifetime risk per unit exposure in working level months (WLM) from these models lead to dose conversion of 10 mSv WLM -1 for the BEIR VI model and 8 mSv WLM -1 for the joint Czech-French model in contrast to the conversion of 5 mSv WLM -1 for the GSF model. (authors)

  1. High dose rate brachytherapy (HDRB) in prostate cancer - technique description and preliminary results

    International Nuclear Information System (INIS)

    Cordova Junior, Ardo Lotar; Salvajoli, Joao Victor; Pelizzon, Antonio CAssio Assis; Cecilio, Paulo Jose

    1998-01-01

    Describe the technique and preliminary results of high dose rate brachytherapy (HDRB) in localized prostate cancer. Subjects methods: Between March, 1997 and April, 1998, 26 patients were treated with external beam radiotherapy (45 to 50.4 Gy - 1.8 Gy per day) and implants (16 Gy in 2 days - twice a day). Median age was 68 years. The distribution by clinical stage was: 5 T1c, 9 T2a, 10 T2b and 2 T3a. Median initial PSA was 16 ng/ml. Results: With a median follow-up of 4 months, 85% of patients showed normal levels of PSA, with a median of 0.6 ng/ml, 60 to 90 days after treatment. Dysuria grades 1 and 2 and proctitis grade 1 were found in 11,3 and 5 patients, respectively. Conclusion: The method is safe, with acceptable early side effects. Longer follow-up is necessary before drawing any conclusions. (author)

  2. Validation of dose-response curve of CRCN-NE - Regional Center for Nuclear Sciences from Northeast Brazil for {sup 60}Co: preliminary results; Validacao da curva dose-resposta do CRCN-NE para {sup 60}Co: resultados preliminares

    Energy Technology Data Exchange (ETDEWEB)

    Mendonca, Julyanne C.G.; Mendes, Mariana E.; Hwang, Suy F.; Lima, Fabiana F. [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Santos, Neide, E-mail: july_cgm@yahoo.com.br [Universidade Federal de Pernambuco (CCB/UFPE), Recife, PE (Brazil). Departamento de Genetica

    2014-07-01

    The cytogenetic study has the chromosomal alterations as biomarkers in absorbed dose estimation by the body of individuals involved in exposure to ionizing radiation by interpreting a dose response calibration curve. Since the development of the technique to the analysis of data, you can see protocol characteristics, leading the International Atomic Energy Agency indicate that any laboratory with intention to carry out biological dosimetry establish their own calibration curves. The Biological Dosimetry Laboratory of the Centro Regional de Ciencias Nucleares (CRCN-NE/CNEN), Brazil, recently established the calibration curve related to gamma radiation ({sup 60}Co). Thus, this work aimed to start the validation of this calibration curve from samples of three different blood donors which were irradiated with an absorbed known single dose of 1 Gy. Samples were exposed to {sup 60}Co source (Glaucoma 220) located in the Department of Nuclear Energy (DEN/UFPE). After fixation with methanol and acetic acid and 5% Giemsa staining, the frequency of chromosomal alterations (dicentric chromosomes, acentric rings and fragments) were established from reading of 500 metaphases per sample and doses were estimated using Dose Estimate program. The results showed that, using the dose-response curve calibration for dicentrics, the dose absorbed estimated for the three individuals ranged from 0.891 - 1,089Gy, taking into account the range of confidence of 95%. By using the dose-response curve for dicentrics added to rings and for the same interval of confidence the doses ranged from 0,849 - 1,081Gy. Thus, the estimative encompassed known absorbed dose the three individuals in confidence interval of 95%. These preliminary results seems to demonstrate that dicentric dose-response curves and dicentrics plus rings established by CRCN-NE / CNEN are valid for dose estimation in exposed individuals. This validation will continue with samples from different individuals at different doses.

  3. Perioperative single high dose ATG-Fresenius S administration as induction immunosuppressive therapy in cadaveric renal transplantation--preliminary results.

    Science.gov (United States)

    Samsel, R; Chmura, A; Włodarczyk, Z; Wyzgał, J; Cieciura, T; Lagiewska, B; Pliszczyński, J; Korczak, G; Lazowski, T; Paczek, L; Wałaszewski, J; Lao, M; Rowiński, W

    1999-01-01

    Monoclonal and polyclonal antilymphocyte antibodies have been used successfully in organ transplantation as induction therapy and in the treatment of acute graft rejection. Used for induction the medication is generally given for the first 7-10 days. The aim of this study was to assess the safety and efficacy of single high dose (9 mg/kg) ATG Fresenius S given perioperatively, before revascularization, to kidney allograft recipients. During last twelve months seventy six, first cadaveric kidney adult recipients were included into the study in two centers (center A-64, center B-12). All patients received triple drug immunosuppression (Neoral, steroids and Cellcept which was replaced by azathioprine after 4 months), and were randomized to receive ATG or not. The follow-up period ranged from 1 month up to 1 year. The preliminary results are very promising, the rejection rate in bolus group was significantly lower than in control. No significant side effects or serious adverse events in both groups were observed.

  4. The thermoluminescence response of Ge-doped flat fibre for proton beam measurements: A preliminary study

    International Nuclear Information System (INIS)

    Hassan, M F; Fadzil, M S Ahmad; Noor, N Mohd; Abdul Rahman, W N Wan; Tominaga, T; Geso, M; Akasaka, H; Bradley, D A

    2017-01-01

    The aim of this study was to investigate the thermoluminescence (TL) response of fabricated 2.3 mol% and 6.0 mol% germanium (Ge) doped flat optical fibres to proton irradiation. The fundamental dosimetric characteristics of the fibres have been investigated including dose linearity, reproducibility and fading. The thermoluminescent dosimeters (TLDs) were used as a reference dosimeter to allow the relative response of the fibres. The results show that Ge-doped flat fibres offer excellent dose linearity over the dose range from 1 Gy up to 10 Gy with correlation of determination (R 2 ) of 0.99. The fibres also demonstrated good reproducibility within the standard deviation (SD) of 0.86% to 6.41%. After 96 days post-irradiation, TLD-100 chips gave rise to the least loss in TL signal at around 18% followed by fabricated 2.3 mol% Ge-doped flat fibres about 24%. This preliminary study has demonstrated that the proposed fabricated Ge-doped flat fibre offers a promising potential for use in proton beam measurements. (paper)

  5. A dose error evaluation study for 4D dose calculations

    Science.gov (United States)

    Milz, Stefan; Wilkens, Jan J.; Ullrich, Wolfgang

    2014-10-01

    Previous studies have shown that respiration induced motion is not negligible for Stereotactic Body Radiation Therapy. The intrafractional breathing induced motion influences the delivered dose distribution on the underlying patient geometry such as the lung or the abdomen. If a static geometry is used, a planning process for these indications does not represent the entire dynamic process. The quality of a full 4D dose calculation approach depends on the dose coordinate transformation process between deformable geometries. This article provides an evaluation study that introduces an advanced method to verify the quality of numerical dose transformation generated by four different algorithms. The used transformation metric value is based on the deviation of the dose mass histogram (DMH) and the mean dose throughout dose transformation. The study compares the results of four algorithms. In general, two elementary approaches are used: dose mapping and energy transformation. Dose interpolation (DIM) and an advanced concept, so called divergent dose mapping model (dDMM), are used for dose mapping. The algorithms are compared to the basic energy transformation model (bETM) and the energy mass congruent mapping (EMCM). For evaluation 900 small sample regions of interest (ROI) are generated inside an exemplary lung geometry (4DCT). A homogeneous fluence distribution is assumed for dose calculation inside the ROIs. The dose transformations are performed with the four different algorithms. The study investigates the DMH-metric and the mean dose metric for different scenarios (voxel sizes: 8 mm, 4 mm, 2 mm, 1 mm 9 different breathing phases). dDMM achieves the best transformation accuracy in all measured test cases with 3-5% lower errors than the other models. The results of dDMM are reasonable and most efficient in this study, although the model is simple and easy to implement. The EMCM model also achieved suitable results, but the approach requires a more complex

  6. Reversal of rocuronium-induced neuromuscular block by the selective relaxant binding agent sugammadex: a dose-finding and safety study

    DEFF Research Database (Denmark)

    Sorgenfrei, Iben F; Norrild, Kathrine; Larsen, Per Bo

    2006-01-01

    Sugammadex (Org 25969) forms a complex with steroidal neuromuscular blocking agents, thereby reversing neuromuscular block. This study investigated the dose-response relation, safety, and pharmacokinetics of sugammadex to reverse rocuronium-induced block.......Sugammadex (Org 25969) forms a complex with steroidal neuromuscular blocking agents, thereby reversing neuromuscular block. This study investigated the dose-response relation, safety, and pharmacokinetics of sugammadex to reverse rocuronium-induced block....

  7. Effects of methylphenidate during emotional processing in amphetamine users: preliminary findings.

    Science.gov (United States)

    Bottelier, M A; Schouw, M L J; de Ruiter, M B; Ruhe, H G; Lindauer, R J L; Reneman, L

    2015-12-01

    D-amphetamine (dAMPH) and methylphenidate (MPH) are stimulants used in the treatment of Attention Deficit Hyperactivity Disorder (ADHD). Preclinical studies have shown that in healthy animals, dAMPH induces dopamine (DA) dysfunction, as evidenced for instance by loss of DA levels and its transporters. It has also been suggested that DA plays an important role in emotional processing, and that altered DA-ergic intervention may modulate amygdala function. To explore the role of the DA system in emotional processing we examined emotional processing using functional magnetic resonance imaging (fMRI) in eight male recreational users of dAMPH and eight male healthy controls. We compared brain activation between both groups during an emotional face-processing task with and without an oral MPH challenge. All subjects were abstinent for at least 2 weeks during the baseline scan. The second scan was performed on the same day 1½ hours after receiving an oral dose of 35 mg MPH. A significant Valence*Group interaction (p = .037) indicated amygdala hyperreactivity to fearful facial expressions in dAMPH users that was robust against adjustment for age (p = .015). Furthermore, duration of amphetamine use in years was positively correlated with amygdala reactivity in dAMPH users (r = .76; p = .029). These exploratory findings are in line with previous findings suggesting that DA plays a role in emotional processing.

  8. MEASURING PLACE ATTACHMENT TO CĂLIMANI NATIONAL PARK (ROMANIA AMONG LOCAL RESIDENTS AND TOURISTS. PRELIMINARY FINDINGS

    Directory of Open Access Journals (Sweden)

    IZABELA AMALIA MIHALCA

    2014-06-01

    Full Text Available Measuring Place Attachment to Călimani National Park (Romania among Local Residents and Tourists. Preliminary Findings. Understanding the attachments that people develop for certain places is an interesting area of study, but with little attention in Romanian empirical research. This study introduces the concepts of place identity and place dependence in relation to a specific area within the local culture of the Land of Dorna. Starting from previous studies carried on western samples, a research instrument measuring the degree and content of place attachment was translated and adapted. 86 respondents (52 residents and 34 tourists filled in the questionnaire. Comparing the degree of attachment, there was no significant difference among the two samples. However, local residents tended to display higher levels of place identity, while tourists displayed more emotional functionality to the study area. Place attachment is deeply embodied in the local culture. Due to the research design the generalization of the results is limited. However, this study may act as a starting point in researching other geographical mental spaces. The lands of Romania are unique social and cultural spaces with specific attachment patterns. Future studies should consider larger and representative samples in order to find additional patterns of attachment among residents and other individuals (e.g. tourists, visitors, new residents, other communities etc..

  9. Lingual-Alveolar Contact Pressure during Speech in Amyotrophic Lateral Sclerosis: Preliminary Findings

    Science.gov (United States)

    Searl, Jeff; Knollhoff, Stephanie; Barohn, Richard J.

    2017-01-01

    Purpose: This preliminary study on lingual-alveolar contact pressures (LACP) in people with amyotrophic lateral sclerosis (ALS) had several aims: (a) to evaluate whether the protocol induced fatigue, (b) to compare LACP during speech (LACP-Sp) and during maximum isometric pressing (LACP-Max) in people with ALS (PALS) versus healthy controls, (c)…

  10. Single high dose intraoperative electrons for advanced stage pancreatic cancer: Phase I pilot study

    International Nuclear Information System (INIS)

    Goldson, A.L.; Ashaveri, E.; Espinoza, M.C.

    1981-01-01

    Phase I toxicity studies with intraoperative radiotherapy proved to be a feasible adjunct to surgery for unresectable malignancies of the pancreas at Howard University Hospital. There have been minimal side effects or complications related to the combination of limited surgical decompression and intraoperative radiotherapy alone. The toxic effects of intraoperative radiotherapy on normal tissues is being assessed on a dose volume basis. Doses of 2000 to 2500 rad in a single exposure to include the pancreas, regional nodes and duodenum are acceptable if the total treatment volume is less than or equal to 100 cm. The tumoricidal effects on the cancer are demonstratable when one reviews the pathological specimens that illustrate massive tumor necrosis and fibros replacement, but in all cases reviewed, viable cancer was noted. Intraoperative radiotherapy, therefore, represents a significant boost dose for resectable, partially resectable or non-resectable tumors when added to conventional external beam irradiation and/or chemotherapy. Preliminary clinical data and minimal toxicity justifies further investigation

  11. Preliminary Findings on Men's Sexual Self-Schema and Sexual Offending: Differences Between Subtypes of Offenders.

    Science.gov (United States)

    Sigre-Leirós, Vera; Carvalho, Joana; Nobre, Pedro

    2016-01-01

    Available literature suggests that sexual self-schemas (i.e., cognitive generalizations about sexual aspects of oneself) influence sexual behavior. Nonetheless, there is a lack of research regarding their role in sexual offending. The aim of the present study was to investigate the relationship between the men's sexual self-schema dimensions (passionate-loving, powerful-aggressive, and open-minded-liberal) and different types of sexual-offending behavior. A total of 50 rapists, 65 child molesters (21 pedophilic, 44 nonpedophilic), and 51 nonsexual offenders answered the Men's Sexual Self-Schema Scale, the Brief Symptom Inventory (BSI), and the Socially Desirable Response Set Measure (SDRS-5). Data were analyzed using multinomial logistic regression, controlling for age, school education, psychological distress, and social desirability. Results showed that rapists as well as nonsexual offenders were more likely to hold the powerful-aggressive sexual self-view compared to pedophilic and nonpedophilic child molesters. Overall, findings seem to be consistent with both a sociocultural component of aggression and the general cognitive profile of offenders. If further research corroborates these preliminary findings, sexual self-concept may be integrated into a comprehensive multifactorial approach of offending behavior.

  12. Dose-Finding Study of Omeprazole on Gastric pH in Neonates with Gastro-Esophageal Acid Reflux Using a Bayesian Sequential Approach.

    Science.gov (United States)

    Kaguelidou, Florentia; Alberti, Corinne; Biran, Valerie; Bourdon, Olivier; Farnoux, Caroline; Zohar, Sarah; Jacqz-Aigrain, Evelyne

    2016-01-01

    Proton pump inhibitors are frequently administered on clinical symptoms in neonates but benefit remains controversial. Clinical trials validating omeprazole dosage in neonates are limited. The objective of this trial was to determine the minimum effective dose (MED) of omeprazole to treat pathological acid reflux in neonates using reflux index as surrogate marker. Double blind dose-finding trial with continual reassessment method of individual dose administration using a Bayesian approach, aiming to select drug dose as close as possible to the predefined target level of efficacy (with a credibility interval of 95%). Neonatal Intensive Care unit of the Robert Debré University Hospital in Paris, France. Neonates with a postmenstrual age ≥ 35 weeks and a pathologic 24-hour intra-esophageal pH monitoring defined by a reflux index ≥ 5% over 24 hours were considered for participation. Recruitment was stratified to 3 groups according to gestational age at birth. Five preselected doses of oral omeprazole from 1 to 3 mg/kg/day. Primary outcome, measured at 35 weeks postmenstrual age or more, was a reflux index reflux index ranging from 5.06 to 27.7% were included. Median age was 37.5 days and median postmenstrual age was 36 weeks. In neonates born at less than 32 weeks of GA (n = 30), the MED was 2.5mg/kg/day with an estimated mean posterior probability of success of 97.7% (95% credibility interval: 90.3-99.7%). The MED was 1mg/kg/day for neonates born at more than 32 GA (n = 24). Omeprazole is extensively prescribed on clinical symptoms but efficacy is not demonstrated while safety concerns do exist. When treatment is required, the daily dose needs to be validated in preterm and term neonates. Optimal doses of omeprazole to increase gastric pH and decrease reflux index below 5% over 24 hours, determined using an adaptive Bayesian design differ among neonates. Both gestational and postnatal ages account for these differences but their differential impact on omeprazole

  13. Standardization of high-dose measurement of electron and gamma ray absorbed doses and dose rates

    International Nuclear Information System (INIS)

    McLaughlin, W.L.

    1985-01-01

    Intense electron beams and gamma radiation fields are used for sterilizing medical devices, treating municipal wastes, processing industrial goods, controlling parasites and pathogens, and extending the shelf-life of foods. Quality control of such radiation processes depends largely on maintaining measurement quality assurance through sound dosimetry procedures in the research leading to each process, in the commissioning of that process, and in the routine dose monitoring practices. This affords documentation as to whether satisfactory dose uniformity is maintained throughout the product and throughout the process. Therefore, dosimetry at high doses and dose rates must in many radiation processes be standardized carefully, so that 'dosimetry release' of a product is verified. This standardization is initiated through preliminary dosimetry intercomparison studies such as those sponsored recently by the IAEA. This is followed by establishing periodic exercises in traceability to national or international standards of absorbed dose and dose rate. Traceability is achieved by careful selection of dosimetry methods and proven reference dosimeters capable of giving sufficiently accurate and precise 'transfer' dose assessments: (1) they must be calibrated or have well-established radiation-yield indices; (2) their radiation response characteristics must be reproducible and cover the dose range of interest; (3) they must withstand the rigours of back-and-forth mailing between a central standardizing laboratory and radiation processing facilities, without excessive errors arising due to instabilities, dosimeter batch non-uniformities, and environmental and handling stresses. (author)

  14. Delineating the relationship between stress mindset and primary appraisals: preliminary findings.

    Science.gov (United States)

    Kilby, Christopher J; Sherman, Kerry A

    2016-01-01

    Stress mindset theory suggests that positive stress beliefs lead to positive, rather than negative, outcomes when engaging with stressors. Similarly, the Transactional Model of Stress predicts that perceiving a stressor as challenging leads to positive outcomes whereas negative perceptions of the stressor as threatening invoke negative outcomes. The aim of this study was to provide preliminary data examining the nature of the relationship between stress mindset and primary appraisals. It was predicted that positive beliefs about stress would be associated with perceiving a stressful situation as more challenging, and inversely related to perceptions of threat. Participants (N = 124) initially completed measures assessing stress mindset, lifetime and current perceived stress, trait anxiety, and self-efficacy. Then participants received a set of instructions regarding a stressful mathematics task, followed by completion of post-manipulation stress mindset and primary appraisals measures, prior to completing the mathematics task. Multiple linear regression analyses revealed that participants who held a greater number of positive beliefs (as opposed to negative beliefs) about stress also perceived the stressor as being more challenging. However, there was no significant relationship between valence of beliefs and threat appraisals. These findings provide initial evidence for the nature of the relationship between valence of stress beliefs and challenge appraisals. Further research is needed to understand how stress beliefs impact on the way in which an individual copes with stressful situations.

  15. Study of the SEY dependence on the electron beams dose and energy

    International Nuclear Information System (INIS)

    Commisso, M.

    2011-01-01

    During operation, the internal walls of modern particle accelerators are subjected to synchrotron radiation irradiation and/or electron bombardment. Such phenomena do affect surface properties such as the secondary electron yield, (SEY). A low SEY is a key parameter to control and overcome any detrimental effect on the accelerator performance eventually induced by the build-up of an Electron Cloud (E C). In laboratory experiments SEY reduction (called scrubbing) has been studied as a function of dose but the actual kinetic energy dependence has never been considered as an important parameter. For this reason and given the peculiar behavior observed for low-energy electrons, we decided to study this dependence accurately. Here we report results of SEY measurements performed bombarding Cu samples obtained from the Large Hadron Collider (Lhc) with different doses of electron beam with energy in the range 10-500 eV. Our results demonstrate that the potentiality of an electron beam to reduce the SEY does not only depend on its dose, but also on its energy. Furthermore, since E C build-up was predicted and observed also the DAΦNE ring, we report some preliminary measurements on the conditioning of Al samples. An overview of future experiments which we will perform in LNF is then given.

  16. Effects of propranolol on conversational reciprocity in autism spectrum disorder: a pilot, double-blind, single-dose psychopharmacological challenge study.

    Science.gov (United States)

    Zamzow, Rachel M; Ferguson, Bradley J; Stichter, Janine P; Porges, Eric C; Ragsdale, Alexandra S; Lewis, Morgan L; Beversdorf, David Q

    2016-04-01

    Pharmacological intervention for autism spectrum disorder (ASD) is an important addition to treatment, yet currently available agents target co-morbid psychiatric concerns, such as aggression and irritability. Propranolol, a beta-adrenergic antagonist with anxiolytic effects, has been shown to improve verbal fluency and working memory in adults and adolescents with ASD in single-dose challenges. The present pilot study explores the acute effects of propranolol on a measure of conversational reciprocity in this population. We also examined whether autonomic activity and anxiety moderate or mediate response to the drug, given relationships between these variables and ASD, as well as the drug's effects. In a within-subject crossover design, 20 individuals with ASD received a single dose of propranolol or placebo during two sessions in a double-blinded, counterbalanced manner. After drug administration, participants performed a conversational reciprocity task by engaging in a short conversation with the researcher. Measurements of autonomic activity and anxiety were obtained before and after drug administration. Propranolol significantly improved performance on the conversational reciprocity task total [d = 0.40] and nonverbal communication domain scores when compared to the placebo condition. However, neither autonomic activity nor anxiety was significantly associated with drug response. Acute propranolol administration improved conversational reciprocity in ASD. Further exploration of these preliminary findings, as well as other potential treatment response predictors, with serial doses is warranted.

  17. Field study to evaluate radiation doses in dental practices

    International Nuclear Information System (INIS)

    Panzer, W.; Scheurer, C.

    1984-05-01

    An inexpensive and simple test device was developed and used in a field study to evaluate entrance dose, dose to an intra-oral film, filtration and field size under routine conditions in more than 150 dental practices. The test device consists of two films of different speed and a set of 5 thin copper filters for a filter analytical determination of the radiation quality. Dentists voluntarily participating in the study were asked to expose the test device like they usually do when examining a molar tooth. The main result was the evidence of a significant dose reduction compared to the findings of similar studies performed in 1970 and 1976. This reduction is due to a general shift to lower values and a complete disappearance of values above 45 mGy (5 R) which in 1970 were still more than 15%. In the same way the number of facilities showing insufficient filtration or collimation had decreased. Nevertheless, a large spread of dose values could still be observed, ranging from less than 0.45 mGy (50 mR) to more than 26 mGy (3 R), for the entrance dose. The most striking result, however, was that such an important parameter like the speed of the films used at the respective unit turned out to have no impact on the entrance dose. (orig./HP)

  18. PRELIMINARY STUDIES ON THE BEHAVIOURAL EFFECTS OF THE METHANOL EXTRACT OF LEONOTIS NEPETIFOLIA LINN STEM IN MICE

    Science.gov (United States)

    Ayanwuyi, Lydia O.; Kwanashie, Helen O.; Hussaini, Isa M.; Yaro, Abdullahi H.

    2016-01-01

    Background: Leonotis nepetifolia Linn (Lamiaceae) is used in traditional medicine for its calming (tranquilizing) effects. The aim of this study was to determine whether there is any scientific justification for this use. To achieve this purpose, we investigated the behavioural effects of the methanol extract of Leonotis nepetifolia stem (37.5, 75 and 150 mg/kg) in mice. Methods: Acute toxicity studies were carried out on the methanol stem extract of Leonotis nepetifolia to determine the LD50. The behavioural tests employed were diazepam-induced sleep onset and duration, hole board assay for exploratory activity, mouse beam walk assay for motor coordination, and the staircase test for the detection of anxiolytic compounds. Preliminary phytochemical screening was also carried out on the extract. Results: The intraperitoneal LD50 value was found to be 3.8 g/kg. The results showed that the extract significantly prolonged the duration of diazepam-induced sleep at the highest dose (150 mg/kg). There was no observable effect on exploratory activity and motor coordination at the doses tested (37.5, 75 and 150 mg/kg). The extract, however, at 150 mg/kg elicited a significant decrease in the number of rearings in the staircase test, an effect also observed in the group of mice injected with an anxiolytic dose of diazepam. The preliminary phytochemical screening revealed the presence of alkaloids, saponins, glycosides and triterpenoids. Conclusion: The results obtained suggest that the crude methanol extract of Leonotis nepetifolia stem possesses some biologically active constituents with potential anxiolytic activity and thus may justify its traditional use as a tranquilizer. PMID:28852715

  19. Efficacy of modest dose irradiation in combination with long-term endocrinal treatment for high-risk prostate cancer. A preliminary report

    International Nuclear Information System (INIS)

    Sasaki, Tomonari; Nakamura, Katsumasa; Shioyama, Yoshiyuki

    2004-01-01

    Although radiotherapy in combination with endocrinal manipulation has been identified as an effective treatment for patients with high-risk prostate cancer, the optimal dose for locoregional control of prostate cancer in combination with hormonal therapy has not yet been determined. The efficacy of modest doses of irradiation (60-62 Gy) combined with long-term endocrinal treatment for patients with high-risk prostate cancer (defined as a pretreatment prostate-specific antigen (PSA) level greater than 20 ng/ml or a Gleason's score of 8-10 or T3-T4 disease) was analyzed in 60 Japanese patients. The patients included in this study had received radical radiotherapy with long-term endocrinal manipulation in the period between 1993 and 2000. The median age of the patients was 70 years (range, 56-83). Neoadjuvant hormonal therapy with a median duration of 3.9 months was performed prior to radiotherapy, and hormonal therapy was continued until recurrence. A median dose of 61.4 Gy (range, 44-71.4) was delivered to the prostate. Pelvic node irradiation was performed in 49 patients (81.6%). After a median follow-up period of 28.5 months, the overall survival, cause-specific survival and biochemical relapse-free survival at 3 years were 94.4%, 96% and 89.8%, respectively. Local failure was observed in one patient, distant metastases were observed in three patients and a late toxic effect greater than Grade 2 was not observed in any patients. This study, though preliminary due to a short-term follow-up period, reveals the possibility that modest doses of irradiation combined with long-term endocrinal treatment could be an effective means of achieving excellent local control of high-risk prostate cancer. (author)

  20. Correlation of patient maximum skin doses in cardiac procedures with various dose indicators

    International Nuclear Information System (INIS)

    Domienik, J.; Papierz, S.; Jankowski, J.; Peruga, J.Z.; Werduch, A.; Religa, W.

    2008-01-01

    In most countries of European Union, legislation requires the determination of the total skin dose received by patients during interventional procedures in order to prevent deterministic damages. Various dose indicators like dose-area product (DAP), cumulative dose (CD) and entrance dose at the patient plane (EFD) are used for patient dosimetry purposes in clinical practice. This study aimed at relating those dose indicators with doses ascribed to the most irradiated areas of the patient skin usually expressed in terms of local maximal skin dose (MSD). The study was performed in two different facilities for two most common cardiac procedures coronary angiography (CA) and percutaneous coronary interventions (PCI). For CA procedures, the registered values of fluoroscopy time, total DAP and MSD were in the range (0.7-27.3) min, (16-317) Gy cm 2 and (43-1507) mGy, respectively, and for interventions, accordingly (2.1-43.6) min, (17-425) Gy cm 2 , (71-1555) mGy. Moreover, for CA procedures, CD and EFD were in the ranges (295-4689) mGy and (121-1768) mGy and for PCI (267-6524) mGy and (68-2279) mGy, respectively. No general and satisfactory correlation was found for safe estimation of MSD. However, results show that the best dose indicator which might serve for rough, preliminary estimation is DAP value. In the study, the appropriate trigger levels were proposed for both facilities. (authors)

  1. Anatomy and histology as socially networked learning environments: some preliminary findings.

    Science.gov (United States)

    Hafferty, Frederic W; Castellani, Brian; Hafferty, Philip K; Pawlina, Wojciech

    2013-09-01

    An exploratory study to better understand the "networked" life of the medical school as a learning environment. In a recent academic year, the authors gathered data during two six-week blocks of a sequential histology and anatomy course at a U.S. medical college. An eight-item questionnaire captured different dimensions of student interactions. The student cohort/network was 48 first-year medical students. Using social network analysis (SNA), the authors focused on (1) the initial structure and the evolution of informal class networks over time, (2) how informal class networks compare to formal in-class small-group assignments in influencing student information gathering, and (3) how peer assignment of professionalism role model status is shaped more by informal than formal ties. In examining these latter two issues, the authors explored not only how formal group assignment persisted over time but also how it functioned to prevent the tendency for groupings based on gender or ethnicity. The study revealed an evolving dynamic between the formal small-group learning structure of the course blocks and the emergence of informal student networks. For example, whereas formal group membership did influence in-class questions and did prevent formation of groups of like gender and ethnicity, outside-class questions and professionalism were influenced more by informal group ties where gender and, to a much lesser extent, ethnicity influence student information gathering. The richness of these preliminary findings suggests that SNA may be a useful tool in examining an array of medical student learning encounters.

  2. Oral sodium phenylbutyrate in patients with recurrent malignant gliomas: a dose escalation and pharmacologic study.

    Science.gov (United States)

    Phuphanich, Surasak; Baker, Sharyn D; Grossman, Stuart A; Carson, Kathryn A; Gilbert, Mark R; Fisher, Joy D; Carducci, Michael A

    2005-04-01

    We determined the maximum tolerated dose (MTD), toxicity profile, pharmacokinetic parameters, and preliminary efficacy data of oral sodium phenylbutyrate (PB) in patients with recurrent malignant gliomas. Twenty-three patients with supratentorial recurrent malignant gliomas were enrolled on this dose escalation trial. Four dose levels of PB were studied: 9, 18, 27, and 36 g/day. Data were collected to assess toxicity, response, survival, and pharmacokinetics. All PB doses of 9, 18, and 27 g/day were well tolerated. At 36 g/day, two of four patients developed dose-limiting grade 3 fatigue and somnolence. At the MTD of 27 g/day, one of seven patients developed reversible grade 3 somnolence. Median survival from time of study entry was 5.4 months. One patient had a complete response for five years, and no partial responses were noted, which yielded an overall response rate of 5%. Plasma concentrations of 706, 818, 1225, and 1605 muM were achieved with doses of 9, 18, 27, and 36 g/day, respectively. The mean value for PB clearance in this patient population was 22 liters/h, which is significantly higher than the 16 liters/h reported in patients with other malignancies who were not receiving P450 enzyme-inducing anticonvulsant drugs (P = 0.038). This study defines the MTD and recommended phase 2 dose of PB at 27 g/day for heavily pretreated patients with recurrent gliomas. The pharmacology of PB appears to be affected by concomitant administration of P450-inducing anticonvulsants.

  3. Comparison of image quality in head CT studies with different dose-reduction strategies

    DEFF Research Database (Denmark)

    Johansen, Jeppe; Nielsen, Rikke; Fink-Jensen, Vibeke

    The number of multi-detector CT examinations is increasing rapidly. They allow high quality reformatted images providing accurate and precise diagnosis at maximum speed. Brain examinations are the most commonly requested studies, and although they come at a lower effective dose than body CT, can...... account to a considerable radiation dose as many patients undergo repeated studies. Therefore, various dose-reduction strategies are applied such as automated tube current and voltage modulation and recently different iterative reconstruction algorithms. However, the trade-off of all dose......-reduction maneuvers is reduction of image quality due to image noise or artifacts. The aim of our study was therefore to find the best diagnostic images with lowest possible dose. We present results of dose- and image quality optimizing strategies of brain CT examinations at our institution. We compare sequential...

  4. Preliminary characterization of the passive neutron dose equivalent monitor with TLDs

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, Norio; Kanai, Katsuta; Momose, Takumaro; Hayashi, Naomi [Japan Nuclear Cycle Development Inst., Tokai Works, Tokai, Ibaraki (Japan); Chen Erhu [Beijing Institute of Nuclear Engineering, Beijing (China)

    2001-02-01

    The passive neutron dose equivalent monitor with TLDs is composed of a cubic polyethylene moderator and TLDs at the center of moderator. This monitor was originally designed for measurements of neutron doses over long-term period of time around the nuclear facilities. In this study, the energy response of this monitor was calculated by Monte Carlo methods and experimentally obtained under {sup 241}Am-Be, {sup 252}Cf and moderated {sup 252}Cf neutron irradiation. Additionally, the responses of two types of conventional neutron dose equivalent meters (rem counters) were also investigated as comparison. The authors concluded that this passive neutron monitor with TLDs had a good energy response similar to conventional rem counters and could evaluate neutron doses within 10% of accuracy to the moderated fission spectra. (author)

  5. Phase I/II dose-finding study of nanoparticle albumin-bound paclitaxel (nab®-Paclitaxel) plus Cisplatin as Treatment for Metastatic Nasopharyngeal Carcinoma.

    Science.gov (United States)

    Huang, Yan; Liang, Wenhua; Yang, Yunpeng; Zhao, Liping; Zhao, Hongyun; Wu, Xuan; Zhao, Yuanyuan; Zhang, Yang; Zhang, Li

    2016-07-13

    This phase I/II study aimed to determine the maximum tolerated dose (MTD) of nanoparticle albumin-bound paclitaxel (nab (®)-paclitaxel) plus cisplatin as treatment for metastatic nasopharyngeal carcinoma (NPC). Patients were enrolled into 1 of 3 dose cohorts, each with 21-day treatment cycles: 1) intravenous (IV) nab-paclitaxel 260 mg/m(2) on day 1; 2) IV nab-paclitaxel 140 mg/m(2) on days 1 and 8; 3) IV nab-paclitaxel 100 mg/m(2) on days 1, 8, and 15. All patients received IV cisplatin 75 mg/m(2) on day 1. Treatment continued for 4-6 cycles, or until progression or unacceptable toxicity. If more than one-third of the patients in a cohort experienced a dose-limiting toxicity (DLT), the dose used in the previous cohort would be designated the MTD. Secreted protein acidic and rich in cysteine (SPARC) expression was detected by immunohistochemistry staining. Sixty-nine patients were enrolled, of whom 64 and 67 were eligible for efficacy and safety analysis, respectively. Two DLTs occurred in cohort 1 (grade 4 febrile neutropenia, grade 3 myalgia), none occurred in cohort 2, and 2 occurred in cohort 3 (both grade 3 fatigue). The MTD was not reached. Partial responses were achieved by 42 patients, 15 had stable disease, and 7 had progressive disease, giving an overall response rate of 66 %. Median progression-free survival was 9 months (95 % CI, 6-12 months). Grade ≥ 3 adverse events were mainly hematologic. There was no significant difference between the 3 cohorts with respect to efficacy or safety. Biomarker analyses indicated that stromal, rather than tumoral, SPARC may predict the response to nab-paclitaxel in NPC. Our findings suggest that nab-paclitaxel plus cisplatin is a highly active regimen with moderate toxicity for the treatment of metastatic NPC, which warrants further investigation in a phase III study. ClinicalTrials.gov ID: NCT01735409 . The trial was registered on November 20th, 2012.

  6. Trends in doses to radiation workers recorded on the Central Index of Dose Information

    International Nuclear Information System (INIS)

    Greenslade, E.; Kendall, G.M.; Fillary, K.; Bines, W.P.

    1991-01-01

    This paper presents a preliminary analysis of the doses stored on the Central Index of Dose Information for the calendar years 1986, 1987 and 1988. Mean doses are low, and both mean doses and the proportion of workers exceeding 15 mSv in a year are decreasing with time. Underground miners are the occupational group receiving the highest doses, though in this and other relatively high dose groups the exposures are falling with time. Only 6% of workers are female and their average individual dose is about half that of men. Patterns of employment are different for women and men but there is a tendency for women to receive lower doses than men even within the same occupation. (author)

  7. Adult health study. Hiroshima preliminary report, 1958-1959

    Energy Technology Data Exchange (ETDEWEB)

    Hollingsworth, J W; Anderson, Jr, P S

    1961-06-28

    The first 4151 clinical examinations of radiation exposed and nonexposed persons in the Hiroshima Adult Health Study have been tabulated and reviewed. No evident differences in past history, medical symptoms, physical examination, laboratory findings, nor disease incidence could be related to the atomic radiation in 1945. The sample is small and represents only a portion of the first cycle of an examination procedure that is planned to continue indefinitely at approximately two year intervals. This report, consisting of a review of the program and the findings in this preliminary sample, includes extensive tabular data (Tables 28-65) from the coded medical information. It was not expected that radiation induced changes would be evident from this sample unless they were of unexpected prominence. The report was prepared primarily to describe the problems inherent in an epidemiologic medical study of this sort, and to review the type of data that can be obtained for future analyses. This analysis was conducted to pinpoint some of the problems; to assist others contemplating this type of medical study; to illuminate for ABCC the data that are being collected; and to suggest ways to use these data most effectively. 16 references, 1 figure, 65 tables.

  8. A preliminary study to detect CT radiation doses by using the γH2AX focus formation assay

    International Nuclear Information System (INIS)

    Zhang Bo; Gong Jianping; Zhang Wei; Yu Zeyang; Zhou Liying; Zhang Hong; Fu Jinxiang

    2010-01-01

    To prospectively determine if γH2AX (phosphorylated form of H2AX histone variant)-based visualization and quantification of DNA damage induced in peripheral blood mononuclear cells (PBMCs) can be used to estimate the radiation dose received after multi-detector computed tomography (CT) by the in vitro study, comprehend the correlation between the dose and the induced γH2AX foci, and explore its prospect. The result showed that, DNA damage first presented as γH2AX foci after CT, which can be detected by fluorescence microscope. The γH2AX focus yields linearly depend on the radiation dose after CT. γH2AX focus yield in blood cells may be a useful quantitative biomarker of human radiation exposure by CT scans. (authors)

  9. A dose-finding, placebo-controlled study on extended-release felodipine once daily in treatment of hypertension.

    Science.gov (United States)

    Cambell, L M; Ross, J R; Goves, J R; Lees, C T; McCullagh, A; Barnes, P; Timerick, S J; Richardson, P D

    1989-12-01

    Hypertensive patients received a beta-blocker plus placebo once daily for 4 weeks. If their diastolic blood pressure (DBP) was then 95-115 mm Hg, they were randomized to receive, in addition to the beta-blocker, placebo (n = 36), felodipine-extended release (ER) 10 mg (n = 36), or felodipine-ER 20 mg (n = 37) in a 4-week double-blind parallel-group trial. All medication was administered once daily and, when BP was measured 24 h after the last dose, felodipine-ER 10 mg reduced DBP by 14 +/- 9 mm Hg (mean +/- SD) from a mean of 103 mm Hg and felodipine-ER 20 mg reduced DBP by 18 +/- 9 mm Gg from 101 mm Hg. The reductions in DBP with both doses of felodipine were greater than reductions with placebo (5 +/- 8 mm Hg, from 102 mm Hg--both p less than 0.001). At the end of the study, 21% of patients receiving placebo had a DBP less than or equal to 90 mm Hg. In contrast, 69% of patients receiving felodipine-ER 10 mg and 82% receiving 20 mg attained this level. More than 90% of patients receiving 10 mg felodipine-ER once daily had a reduction in DBP greater than 5 mm Hg 24 h postdose. Felodipine-ER was well tolerated. Felodipine-ER once daily is an effective antihypertensive drug for patients who require therapy in addition to a beta-blocker; the tolerability in this study was good, and a starting dose greater than 10 mg once daily is not indicated.

  10. A study on mice exposure dose for low-dose gamma-irradiation using glass dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Sung Jin; Kim, Hyo Jin; Kim, Hyun; Jeong, Dong Hyeok; Son, Tae Gen; Kim, Jung Ki; Yang, Kwang Mo; Kang, Yeong Rok [Research Center, Dongnam Institute of Radiological and Medical Sciences, Busan (Korea, Republic of); Nam, Sang Hee [Dept. of Biomedical Engineering, Inje University, Gimhae (Korea, Republic of)

    2015-12-15

    The low dose radiation is done for a long period, thus researchers have to know the exact dose distribution for the irradiated mouse. This research has been conducted in order to find out methods in transmitting an exact dose to mouse in a mouse irradiation experiment carried out using {sup 137}C{sub s} irradiation equipment installed in the DIRAMS (Dongnam Institution of Radiological and Medical Sciences) research center. We developed a single mouse housing cage and shelf with adjustable geometric factors such as distance and angle from collimator. The measurement of irradiated dose showed a maximal 42% difference of absorbed dose from the desired dose in the conventional irradiation system, whereas only 6% difference of the absorbed dose was measured in the self-developed mouse apartment system. In addition, multi mice housing showed much difference of the absorbed dose in between head and body, compared to single mouse housing in the conventional irradiation system. This research may allow further research about biological effect assessment for the low dose irradiation using the self-developed mouse apartment to provide more exact doses which it tries to transmit, and to have more reliability for the biological analysis results.

  11. Dose-Finding Study of Omeprazole on Gastric pH in Neonates with Gastro-Esophageal Acid Reflux Using a Bayesian Sequential Approach.

    Directory of Open Access Journals (Sweden)

    Florentia Kaguelidou

    Full Text Available Proton pump inhibitors are frequently administered on clinical symptoms in neonates but benefit remains controversial. Clinical trials validating omeprazole dosage in neonates are limited. The objective of this trial was to determine the minimum effective dose (MED of omeprazole to treat pathological acid reflux in neonates using reflux index as surrogate marker.Double blind dose-finding trial with continual reassessment method of individual dose administration using a Bayesian approach, aiming to select drug dose as close as possible to the predefined target level of efficacy (with a credibility interval of 95%.Neonatal Intensive Care unit of the Robert Debré University Hospital in Paris, France.Neonates with a postmenstrual age ≥ 35 weeks and a pathologic 24-hour intra-esophageal pH monitoring defined by a reflux index ≥ 5% over 24 hours were considered for participation. Recruitment was stratified to 3 groups according to gestational age at birth.Five preselected doses of oral omeprazole from 1 to 3 mg/kg/day.Primary outcome, measured at 35 weeks postmenstrual age or more, was a reflux index <5% during the 24-h pH monitoring registered 72±24 hours after omeprazole initiation.Fifty-four neonates with a reflux index ranging from 5.06 to 27.7% were included. Median age was 37.5 days and median postmenstrual age was 36 weeks. In neonates born at less than 32 weeks of GA (n = 30, the MED was 2.5mg/kg/day with an estimated mean posterior probability of success of 97.7% (95% credibility interval: 90.3-99.7%. The MED was 1mg/kg/day for neonates born at more than 32 GA (n = 24.Omeprazole is extensively prescribed on clinical symptoms but efficacy is not demonstrated while safety concerns do exist. When treatment is required, the daily dose needs to be validated in preterm and term neonates. Optimal doses of omeprazole to increase gastric pH and decrease reflux index below 5% over 24 hours, determined using an adaptive Bayesian design differ

  12. Dose-Volume Analysis of Radiation Nephropathy in Children: Preliminary Report of the Risk Consortium

    International Nuclear Information System (INIS)

    Boelling, Tobias; Ernst, Iris; Pape, Hildegard; Martini, Carmen; Ruebe, Christian; Timmermann, Beate; Fischedick, Karin; Kortmann, Rolf-Dieter; Willich, Normann

    2011-01-01

    Purpose: To characterize kidney function in children and adolescents who had undergone radiation treatment that included parts of the kidney. Methods and Materials: Patients receiving radiotherapy during childhood or adolescence were prospectively registered in Germany's Registry for the Evaluation of Side Effects after Radiation in Childhood and Adolescence (RiSK). Detailed information was recorded regarding radiation doses at the organs at risk since 2001 all over Germany. Toxicity evaluation was performed according to standardized Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer criteria. Results: Up to May 2009, 1086 patients from 62 centers were recruited, including 126 patients (median age, 10.2 years) who underwent radiotherapy to parts of the kidneys. Maximal late toxicity (median follow-up 28.5 months in 74 patients) was characterized as Grade 0 (n = 65), 1 (n = 7) or 2 (n = 2). All patients with late effects had received potentially nephrotoxic chemotherapy. A statistically significant difference between patients with and without Grade 1 toxicity, revealing higher exposed kidney volumes in patients with toxicity, was seen for the kidney volume exposed to 20 Gy (V20; p = 0.031) and 30 Gy (V30; p = 0.003). Conclusions: Preliminary data indicate that radiation-induced kidney function impairment is rare in current pediatric multimodal treatment approaches. In the future, RiSK will be able to provide further detailed data regarding dose-volume effect relationships of radiation-associated side effects in pediatric oncology patients.

  13. Keeping rail on track: preliminary findings on safety culture in Australian rail.

    Science.gov (United States)

    Blewett, Verna; Rainbird, Sophia; Dorrian, Jill; Paterson, Jessica; Cattani, Marcus

    2012-01-01

    'Safety culture' is identified in the literature as a critical element of healthy and safe workplaces. How can rail organizations ensure that consistently effective work health and safety cultures are maintained across the diversity of their operations? This paper reports on research that is currently underway in the Australian rail industry aimed at producing a Model of Best Practice in Safety Culture for the industry. Located in rail organizations dedicated to the mining industry as well as urban rail and national freight operations, the research examines the constructs of organizational culture that impact on the development and maintenance of healthy and safe workplaces. The research uses a multi-method approach incorporating quantitative (survey) and qualitative (focus groups, interviews and document analysis) methods along with a participative process to identify interventions to improve the organization and develop plans for their implementation. The research uses as its analytical framework the 10 Platinum Rules, from the findings of earlier research in the New South Wales (Australia) mining industry, Digging Deeper. Data collection is underway at the time of writing and preliminary findings are presented at this stage. The research method may be adapted for use as a form of organizational review of safety and health in organizational culture.

  14. Dataset for Phase I randomized clinical trial for safety and tolerability of GET 73 in single and repeated ascending doses including preliminary pharmacokinetic parameters.

    Science.gov (United States)

    Haass-Koffler, Carolina L; Goodyear, Kimberly; Long, Victoria M; Tran, Harrison H; Loche, Antonella; Cacciaglia, Roberto; Swift, Robert M; Leggio, Lorenzo

    2017-12-01

    The data in this article outline the methods used for the administration of GET 73 in the first time-in-human manuscript entitled "Phase I randomized clinical trial for the safety, tolerability and preliminary pharmacokinetics of the mGluR5 negative allosteric modulator GET 73 following single and repeated doses in healthy male volunteers" (Haass-Koffler et al., 2017) [1]. Data sets are provided in two different manners. The first series of tables provided includes procedural information about the experiments conducted. The next series of tables provided includes Pharmacokinetic (PK) parameters for GET 73 and its main metabolite MET 2. This set of data is comprised by two experiments: Experiment 1 references a single ascending dose administration of GET 73 and Experiment 2 references a repeated ascending dose administration of GET 73.

  15. R and D Requirements, RF Gun Mode Studies, FEL-2 Steady-State Studies, Preliminary FEL-1 Time-Dependent Studies, and Preliminary Layout Option Investigation

    International Nuclear Information System (INIS)

    Byrd, John; Corlett, John; Doolittle, Larry; Fawley, William; Lidia, Steven; Penn, Gregory; Ratti, Alex; Staples, John; Wilcox Russell; Wurtele, Jonathan; Zholents, Alexander

    2005-01-01

    This report constitutes the third deliverable of LBNLs contracted role in the FERMI (at) Elettra Technical Optimization study. It describes proposed RandD activities for the baseline design of the Technical Optimization Study, initial studies of the RF gun mode-coupling and potential effects on beam dynamics, steady-state studies of FEL-2 performance to 10 nm, preliminary studies of time-dependent FEL-1 performance using electron bunch distribution from the start-to-end studies, and a preliminary investigation of a configuration with FEL sinclined at a small angle from the line of the linac

  16. Development of CER-001: Preclinical Dose Selection Through to Phase I Clinical Findings.

    Science.gov (United States)

    Keyserling, Constance H; Barbaras, Ronald; Benghozi, Renee; Dasseux, Jean-Louis

    2017-05-01

    CER-001 comprises recombinant human apolipoprotein A-I complexed with phospholipids that mimics natural, nascent, pre-β high-density lipoprotein (HDL). We present animal model data showing dose-dependent increases in cholesterol efflux with CER-001 and its subsequent elimination by reverse lipid transport, together with inhibition of atherosclerotic plaque progression. We report the first phase I study results with CER-001 in humans, starting at 0.25 mg/kg, which is 1/80th of the safe dose (20 mg/kg) established in 4-week multiple-dose animal studies dosed every second day. Healthy volunteers, 18-55 years old with a low-density lipoprotein-cholesterol:HDL-cholesterol ratio greater than 3.0, received single intravenous escalating doses of CER-001 (0.25-45.0 mg/kg) and placebo in a double-blind randomised cross-over fashion. Subjects were followed up for 3 weeks post-dose. Assessments included adverse event monitoring, blood sampling, and clinical laboratory measurements. Thirty-two subjects were enrolled. All CER-001 doses (0.25-45 mg/kg) were safe and well tolerated, with an adverse event profile similar to placebo. Effects on clinical chemistry, haematology and coagulation parameters were comparable to placebo. No adverse effects of CER-001 on electrocardiograms were observed. No antibodies to apolipoprotein A-I were detected following single-dose administration of CER-001. Plasma apolipoprotein A-I levels increased in a dose-related manner and returned to baseline by 24 h post-dose for doses up to 10 mg/kg but remained in circulation for >72 h post-dose for doses >10 mg/kg. CER-001 caused elevations in plasma cholesterol and total and unesterified cholesterol in the HDL fraction. Mobilisation of unesterified cholesterol in the HDL fraction was seen with CER-001 at doses as low as 2 mg/kg. CER-001 is well tolerated when administered to humans as single doses up to 45 mg/kg and mobilises and eliminates cholesterol via reverse lipid transport.

  17. A preliminary assessment of selected atmospheric dispersion, food-chain transport, and dose-to-man computer codes for use by the DOE Office of Civilian Radioactive Waste Management

    International Nuclear Information System (INIS)

    Riggle, K.J.; Roddy, J.W.

    1989-02-01

    This work is part of the ongoing Systems Modeling Program at Oak Ridge National Laboratory, which is assisting the DOE Office of Civilian Radioactive Waste Management in selecting appropriate computer codes for the process of licensing a high-level radioactive waste repository or a monitored retrievable storage facility. A preliminary study of codes for predicting dose to man following airborne releases of radionuclides is described. These codes use models for estimating atmospheric dispersion of activity and deposition onto the ground surface, exposures via external irradiation, inhalation of airborne activity, and ingestion following transport through terrestrial food chains, and the dose per unit exposure for each exposure mode. A set of criteria is given for use in choosing codes for further examination. From a list of over 150 computer codes, five were selected for review

  18. Prophylactic Oral Dextrose Gel for Newborn Babies at Risk of Neonatal Hypoglycaemia: A Randomised Controlled Dose-Finding Trial (the Pre-hPOD Study).

    Science.gov (United States)

    Hegarty, Joanne Elizabeth; Harding, Jane Elizabeth; Gamble, Gregory David; Crowther, Caroline Anne; Edlin, Richard; Alsweiler, Jane Marie

    2016-10-01

    Neonatal hypoglycaemia is common, affecting up to 15% of newborns, and can cause brain damage. Currently, there are no strategies, beyond early feeding, to prevent neonatal hypoglycaemia. Our aim was to determine a dose of 40% oral dextrose gel that will prevent neonatal hypoglycaemia in newborn babies at risk. We conducted a randomised, double-blind, placebo-controlled dose-finding trial of buccal dextrose gel to prevent neonatal hypoglycaemia at two hospitals in New Zealand. Babies at risk of hypoglycaemia (infant of a mother with diabetes, late preterm delivery, small or large birthweight, or other risk factors) but without indication for admission to a neonatal intensive care unit (NICU) were randomly allocated either to one of four treatment groups: 40% dextrose at one of two doses (0.5 ml/kg = 200 mg/kg, or 1 ml/kg = 400 mg/kg), either once at 1 h of age or followed by three additional doses of dextrose (0.5 ml/kg before feeds in the first 12 h); or to one of four corresponding placebo groups. Treatments were administered by massaging gel into the buccal mucosa. The primary outcome was hypoglycaemia (dextrose gel (relative risk [RR] 0.68; 95% confidence interval [CI] 0.47-0.99, p = 0.04) but was not significantly different between dose groups (p = 0.21). Compared to multiple doses, single doses of gel were better tolerated, quicker to administer, and less messy, but these limitations were not different between dextrose and placebo gel groups. Babies who received any dose of dextrose gel were less likely to develop hypoglycaemia than those who received placebo (RR 0.79; 95% CI 0.64-0.98, p = 0.03; number needed to treat = 10, 95% CI 5-115). Rates of NICU admission were similar (RR 0.64; 95% CI 0.33-1.25, p = 0.19), but admission for hypoglycaemia was less common in babies randomised to dextrose gel (RR 0.46; 95% CI 0.21-1.01, p = 0.05). Rates of breastfeeding were similar in both groups. Adverse effects were uncommon and not different between groups. A

  19. Preliminary Study of 20 MWth Experiment Power Reactor based on Pebble Bed Reactor

    Science.gov (United States)

    Irwanto, Dwi; Permana, Sidik; Pramuditya, Syeilendra

    2017-07-01

    In this study, preliminary design calculations for experimental small power reactor (20 MWt) based on Pebble Bed Reactor (PBR) are performed. PBR technology chosen due to its advantages in neutronic and safety aspects. Several important parameters, such as fissile enrichment, number of fuel passes, burnup and effective multiplication factor are taken into account in the calculation to find neutronic characteristics of the present reactor design.

  20. Lithium carbonate in amyotrophic lateral sclerosis: lack of efficacy in a dose-finding trial.

    Science.gov (United States)

    Chiò, A; Borghero, G; Calvo, A; Capasso, M; Caponnetto, C; Corbo, M; Giannini, F; Logroscino, G; Mandrioli, J; Marcello, N; Mazzini, L; Moglia, C; Monsurrò, M R; Mora, G; Patti, F; Perini, M; Pietrini, V; Pisano, F; Pupillo, E; Sabatelli, M; Salvi, F; Silani, V; Simone, I L; Sorarù, G; Tola, M R; Volanti, P; Beghi, E

    2010-08-17

    A neuroprotective effect of lithium in amyotrophic lateral sclerosis (ALS) has been recently reported. We performed a multicenter trial with lithium carbonate to assess its tolerability, safety, and efficacy in patients with ALS, comparing 2 different target blood levels (0.4-0.8 mEq/L, therapeutic group [TG], vs 0.2-0.4 mEq/L, subtherapeutic group [STG]). The study was a multicenter, single-blind, randomized, dose-finding trial, conducted from May 2008 to November 2009 in 21 Italian ALS centers. The trial was registered with the public database of the Italian Agency for Drugs (http://oss-sper-clin.agenziafarmaco.it/) (EudraCT number 2008-001094-15). As of October 2009, a total of 171 patients had been enrolled, 87 randomized to the TG and 84 to the STG. The interim data analysis, performed per protocol, showed that 117 patients (68.4%) discontinued the study because of death/tracheotomy/severe disability, adverse events (AEs)/serious AEs (SAEs), or lack of efficacy. The Data Monitoring Committee recommended stopping the trial on November 2, 2009. Lithium was not well-tolerated in this cohort of patients with ALS, even at subtherapeutic doses. The 2 doses were equivalent in terms of survival/severe disability and functional data. The relatively high frequency of AEs/SAEs and the reduced tolerability of lithium raised serious doubts about its safety in ALS. The study provides Class II evidence that therapeutic (0.4-0.8 mEq/L) vs subtherapeutic (0.2-0.4 mEq/L) lithium carbonate did not differ in the primary outcome of efficacy (survival/loss of autonomy) in ALS. Both target levels led to dropouts in more than 30% of participants due to patient-perceived lack of efficacy and AEs.

  1. Oral sodium phenylbutyrate in patients with recurrent malignant gliomas: A dose escalation and pharmacologic study1

    Science.gov (United States)

    Phuphanich, Surasak; Baker, Sharyn D.; Grossman, Stuart A.; Carson, Kathryn A.; Gilbert, Mark R.; Fisher, Joy D.; Carducci, Michael A.

    2005-01-01

    We determined the maximum tolerated dose (MTD), toxicity profile, pharmacokinetic parameters, and preliminary efficacy data of oral sodium phenylbutyrate (PB) in patients with recurrent malignant gliomas. Twenty-three patients with supratentorial recurrent malignant gliomas were enrolled on this dose escalation trial. Four dose levels of PB were studied: 9, 18, 27, and 36 g/day. Data were collected to assess toxicity, response, survival, and pharmacokinetics. All PB doses of 9, 18, and 27 g/day were well tolerated. At 36 g/day, two of four patients developed dose-limiting grade 3 fatigue and somnolence. At the MTD of 27 g/day, one of seven patients developed reversible grade 3 somnolence. Median survival from time of study entry was 5.4 months. One patient had a complete response for five years, and no partial responses were noted, which yielded an overall response rate of 5%. Plasma concentrations of 706, 818, 1225, and 1605 μM were achieved with doses of 9, 18, 27, and 36 g/day, respectively. The mean value for PB clearance in this patient population was 22 liters/h, which is significantly higher than the 16 liters/h reported in patients with other malignancies who were not receiving P450 enzyme–inducing anticonvulsant drugs (P = 0.038). This study defines the MTD and recommended phase 2 dose of PB at 27 g/day for heavily pretreated patients with recurrent gliomas. The pharmacology of PB appears to be affected by concomitant administration of P450-inducing anticonvulsants. PMID:15831235

  2. Dose response of artificial irradiation of fluvial sediment sample for ESR dating

    International Nuclear Information System (INIS)

    Liu Chunru; Yin Gongming; Gao Lu; Li Jianping; Han Fei; Lin Min

    2011-01-01

    ESR dating samples need be irradiated to obtain dose response curve and the equivalent dose. The artificial dose rate is about 1 x 10 -1 -1 x 10 2 Gy/min, whereas the natural dose rate is about 3 Gy/ka. Therefore, one must be sure whether the much higher artificial dose rate is suitable for the ESR dating study. In this paper, we use different artificial dose rate to irradiate the same fluvial sample and measure the quartz Al centre ESR signal under the same conditions. The dose response curves are compared, in an attempt to gain a preliminary knowledge on that problem and build a good foundation for our ESR dating studies on fluvial samples. (authors)

  3. Preliminary Shielding Analysis for HCCB TBM Transport

    Science.gov (United States)

    Miao, Peng; Zhao, Fengchao; Cao, Qixiang; Zhang, Guoshu; Feng, Kaiming

    2015-09-01

    A preliminary shielding analysis on the transport of the Chinese helium cooled ceramic breeder test blanket module (HCCB TBM) from France back to China after being irradiated in ITER is presented in this contribution. Emphasis was placed on irradiation safety during transport. The dose rate calculated by MCNP/4C for the conceptual package design satisfies the relevant dose limits from IAEA that the dose rate 3 m away from the surface of the package containing low specific activity III materials should be less than 10 mSv/h. The change with location and the time evolution of dose rates after shutdown have also been studied. This will be helpful for devising the detailed transport plan of HCCB TBM back to China in the near future. supported by the Major State Basic Research Development Program of China (973 Program) (No. 2013GB108000)

  4. SU-F-T-204: A Preliminary Approach of Reducing Contralateral Breast and Heart Dose in Left Sided Whole Breast Cancer Patients Utilizing Proton Beams

    Energy Technology Data Exchange (ETDEWEB)

    Islam, M; Algan, O; Jin, H; Ahmad, S; Hossain, S [University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States)

    2016-06-15

    Purpose: To investigate the plan quality and feasibility of a hybrid plan utilizing proton and photon fields for superior coverage in the internal mammary (IM) and supraclavicular (S/C) regions while minimizing heart and contralateral breast dose for the left-sided whole breast cancer patient treatment. Methods: This preliminary study carried out on single left-sided intact breast patient involved IM and S/C nodes. The IM and S/C node fields of the 5-Field 3DCRT photon-electron base plan were replaced by two proton fields. These two along with two Field-in-Field tangential photon fields were optimized for comparable dose coverage. The treatment plans were done using Eclipse TPS for the total dose of 46Gy in 23 fractions with 95% of the prescription dose covering 95% of the RTOG PTV. The 3DCRT photon-electron and 4-Field photon-proton hybrid plans were compared for the PTV dose coverage as well as dose to OARs. Results: The overall RTOG PTV coverage for proton-hybrid and 3DCRT plan was comparable (95% of prescription dose covers 95% PTV volume). In proton-hybrid plan, 99% of IM volume received 100% dose whereas in 3DCRT only 77% received 100% dose. For S/C regions, 97% and 77% volume received 100% prescription dose in proton-hybrid and 3DCRT plans, respectively. The heart mean dose, V3Gy(%), and V5Gy(%) was 2.2Gy, 14.4%, 9.8% for proton-hybrid vs. 4.20 Gy, 21.5%, and 39% for 3DCRT plan, respectively. The maximum dose to the contralateral breast was 39.75Gy for proton-hybrid while 56.87Gy for 3DCRT plan. The mean total lung dose, V20Gy(%), and V30Gy(%) was 5.68Gy, 11.3%, 10.5% for proton-hybrid vs. 5.90Gy, 9.8%, 7.2% for 3DCRT, respectively. Conclusion: The protonhybrid plan can offer better dose coverage to the involved lymphatic tissues while lower doses to the heart and contralateral breast. More treatment plans are currently in progress before being implemented clinically.

  5. Dose-to-man studies

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    Dose-to-Man Studies focused on developing computer data handling and computer modules which permit easy, rapid assessment of the dose to southeastern United States populations from routine or accidental releases of radionuclides to atmospheric and stream systems

  6. Two preliminary studies on sleep and psychotherapy.

    Science.gov (United States)

    Karle, W; Hopper, M; Corriere, R; Hart, J; Switzer, A

    1977-09-01

    Two preliminary studies were conducted to assess the effects of an intensive outpatient psychotherapy, Feeling Therapy, on sleep. This therapy was chosen because of its demonstrated ability to affect its patients' dreams. In the first study a newly entering female patient was recorded across the first three weeks of intensive daily therapy. In contrast to two control subjects recorded across a similar time period, she demonstrated low REM times and short REM latencies on the average, and considerably greater variability in nearly every parameter. In the second study, two patients were recorded across three days (the middle of which was the day of a therapy session) first when new in therapy and then again after two and one-half years of therapy. It was found that when new in therapy both subjects spent nights of significantly altered sleep the day of the therapy session. One subject showed no REM sleep whatsoever while the other showed a 10 min REM latency and low REM time. The significance of these findings and the direction of future research is discussed.

  7. An Investigation of the Academic Information Finding and Re-finding Behavior on the Web

    Directory of Open Access Journals (Sweden)

    Hsiao-Tieh Pu

    2014-12-01

    Full Text Available Academic researchers often need and re-use relevant information found after a period of time. This preliminary study used various methods, including experiments, interviews, search log analysis, sequential analysis, and observation to investigate characteristics of academic information finding and re-finding behavior. Overall, the participants in this study entered short queries either in finding or re-finding phases. Comparatively speaking, the participants entered greater number of queries, modified more queries, browsed more web pages, and stayed longer on web pages in the finding phase. On the other hand, in the re-finding phase, they utilized personal information management tools to re-find instead of finding again using search engine, such as checking browsing history; moreover, they tend to input less number of queries and stayed shorter on web pages. In short, the participants interacted more with the retrieval system during the finding phase, while they increased the use of personal information management tools in the re-finding phase. As to the contextual clues used in re-finding phase, the participants used less clues from the target itself, instead, they used indirect clues more often, especially location-related information. Based on the results of sequential analysis, the transition states in the re-finding phase was found to be more complex than those in the finding phase. Web information finding and re-finding behavior is an important and novel area of research. The preliminary results would benefit research on Web information re-finding behavior, and provide useful suggestions for developing personal academic information management systems. [Article content in Chinese

  8. Phase I/II dose-finding study of nanoparticle albumin-bound paclitaxel (nab®-Paclitaxel) plus Cisplatin as Treatment for Metastatic Nasopharyngeal Carcinoma

    International Nuclear Information System (INIS)

    Huang, Yan; Liang, Wenhua; Yang, Yunpeng; Zhao, Liping; Zhao, Hongyun; Wu, Xuan; Zhao, Yuanyuan; Zhang, Yang; Zhang, Li

    2016-01-01

    This phase I/II study aimed to determine the maximum tolerated dose (MTD) of nanoparticle albumin-bound paclitaxel (nab ® -paclitaxel) plus cisplatin as treatment for metastatic nasopharyngeal carcinoma (NPC). Patients were enrolled into 1 of 3 dose cohorts, each with 21-day treatment cycles: 1) intravenous (IV) nab-paclitaxel 260 mg/m 2 on day 1; 2) IV nab-paclitaxel 140 mg/m 2 on days 1 and 8; 3) IV nab-paclitaxel 100 mg/m 2 on days 1, 8, and 15. All patients received IV cisplatin 75 mg/m 2 on day 1. Treatment continued for 4–6 cycles, or until progression or unacceptable toxicity. If more than one-third of the patients in a cohort experienced a dose-limiting toxicity (DLT), the dose used in the previous cohort would be designated the MTD. Secreted protein acidic and rich in cysteine (SPARC) expression was detected by immunohistochemistry staining. Sixty-nine patients were enrolled, of whom 64 and 67 were eligible for efficacy and safety analysis, respectively. Two DLTs occurred in cohort 1 (grade 4 febrile neutropenia, grade 3 myalgia), none occurred in cohort 2, and 2 occurred in cohort 3 (both grade 3 fatigue). The MTD was not reached. Partial responses were achieved by 42 patients, 15 had stable disease, and 7 had progressive disease, giving an overall response rate of 66 %. Median progression-free survival was 9 months (95 % CI, 6–12 months). Grade ≥ 3 adverse events were mainly hematologic. There was no significant difference between the 3 cohorts with respect to efficacy or safety. Biomarker analyses indicated that stromal, rather than tumoral, SPARC may predict the response to nab-paclitaxel in NPC. Our findings suggest that nab-paclitaxel plus cisplatin is a highly active regimen with moderate toxicity for the treatment of metastatic NPC, which warrants further investigation in a phase III study. ClinicalTrials.gov ID: NCT01735409. The trial was registered on November 20th, 2012. The online version of this article (doi:10.1186/s12885

  9. Warfarin Dosing Algorithms Underpredict Dose Requirements in Patients Requiring ≥7 mg Daily: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Saffian, S M; Duffull, S B; Wright, Dfb

    2017-08-01

    There is preliminary evidence to suggest that some published warfarin dosing algorithms produce biased maintenance dose predictions in patients who require higher than average doses. We conducted a meta-analysis of warfarin dosing algorithms to determine if there exists a systematic under- or overprediction of dose requirements for patients requiring ≥7 mg/day across published algorithms. Medline and Embase databases were searched up to September 2015. We quantified the proportion of over- and underpredicted doses in patients whose observed maintenance dose was ≥7 mg/day. The meta-analysis included 47 evaluations of 22 different warfarin dosing algorithms from 16 studies. The meta-analysis included data from 1,492 patients who required warfarin doses of ≥7 mg/day. All 22 algorithms were found to underpredict warfarin dosing requirements in patients who required ≥7 mg/day by an average of 2.3 mg/day with a pooled estimate of underpredicted doses of 92.3% (95% confidence interval 90.3-94.1, I 2 = 24%). © 2017 American Society for Clinical Pharmacology and Therapeutics.

  10. A phase I dose-finding study of 5-azacytidine in combination with sodium phenylbutyrate in patients with refractory solid tumors.

    Science.gov (United States)

    Lin, Jianqing; Gilbert, Jill; Rudek, Michelle A; Zwiebel, James A; Gore, Steve; Jiemjit, Anchalee; Zhao, Ming; Baker, Sharyn D; Ambinder, Richard F; Herman, James G; Donehower, Ross C; Carducci, Michael A

    2009-10-01

    This was a phase I trial to determine the minimal effective dose and optimal dose schedule for 5-azacytidine (5-AC) in combination with sodium phenylbutyrate in patients with refractory solid tumors. The pharmacokinetics, pharmacodynamics, and antineoplastic effects were also studied. Three dosing regimens were studied in 27 patients with advanced solid tumors, and toxicity was recorded. The pharmacokinetics of the combination of drugs was evaluated. Repeat tumor biopsies and peripheral blood mononuclear cells (PBMC) were analyzed to evaluate epigenetic changes in response to therapy. EBV titers were evaluated as a surrogate measure for gene re-expression of epigenetic modulation in PBMC. The three dose regimens of 5-AC and phenylbutyrate were generally well tolerated and safe. A total of 48 cycles was administrated to 27 patients. The most common toxicities were bone marrow suppression-related neutropenia and anemia, which were minor. The clinical response rate was disappointing for the combination of agents. One patient showed stable disease for 5 months whereas 26 patients showed progressive disease as the best tumor response. The administration of phenylbutyrate and 5-AC did not seem to alter the pharmacokinetics of either drug. Although there were individual cases of targeted DNA methyltransferase activity and histone H3/4 acetylation changes from paired biopsy or PBMC, no conclusive statement can be made based on these limited correlative studies. The combination of 5-AC and phenylbutyrate across three dose schedules was generally well tolerated and safe, yet lacked any real evidence for clinical benefit.

  11. Preliminary survey of absorbed dose rates in air at Guarapari and Meaipe in Brazil

    International Nuclear Information System (INIS)

    Fujinami, Naoto; Koga, Taeko; Morishima, Hiroshige

    1999-01-01

    A preliminary survey of the gamma-ray exposure rate was carried out at Guarapari and Meaipe in Brazil in September 1998. In those areas, exposure rates in the streets ranged from 0.1 to 0.4 μGy/h except for a few places such as near the beaches. Exposure rates inside houses were lower than 0.2 μGy/h except for two houses where an exposure rate of 0.4 μGy/h was measured. Our effective dose rate from external terrestrial irradiation was 0.17 μSv/h on the average during the period of our three-day stay in Guarapari (outdoors and indoors). These values are lower than those observed in the 1960s, which were cited in UNSCEAR reports. This fact suggests that the natural radiation environment of Guarapari has varied with urbanization, which brought paved streets, and changes in the structure and building materials of houses. A detailed survey is necessary in order to evaluate the present exposure rates in these areas. (author)

  12. MDMA-assisted psychotherapy using low doses in a small sample of women with chronic posttraumatic stress disorder.

    Science.gov (United States)

    Bouso, José Carlos; Doblin, Rick; Farré, Magí; Alcázar, Miguel Angel; Gómez-Jarabo, Gregorio

    2008-09-01

    The purpose of this study was to investigate the safety of different doses of MDMA-assisted psychotherapy administered in a psychotherapeutic setting to women with chronic PTSD secondary to a sexual assault, and also to obtain preliminary data regarding efficacy. Although this study was originally planned to include 29 subjects, political pressures led to the closing of the study before it could be finished, at which time only six subjects had been treated. Preliminary results from those six subjects are presented here. We found that low doses of MDMA (between 50 and 75 mg) were both psychologically and physiologically safe for all the subjects. Future studies in larger samples and using larger doses are needed in order to further clarify the safety and efficacy of MDMA in the clinical setting in subjects with PTSD.

  13. Penile bulb dose and impotence after three-dimensional conformal radiotherapy for prostate cancer on RTOG 9406: Findings from a prospective, multi-institutional, phase I/II dose-escalation study

    International Nuclear Information System (INIS)

    Roach, Mack; Winter, Kathryn; Michalski, Jeffrey M.; Cox, James D.; Purdy, James A.; Bosch, Walter; Lin Xiao; Shipley, William S.

    2004-01-01

    Purpose: To assess the relationship between the dose to the bulb of the penis and the risk of impotence in men treated on Radiation Therapy Oncology Group (RTOG) 9406. Methods and materials: Men enrolled on a Phase I/II dose-escalation study, RTOG 9406, who were reported to be potent at entry and evaluable (n = 158) were selected for inclusion. Follow-up evaluations were scheduled every 3, 4, and 6 months for the first, second, and the third through fifth years, then annually. At each follow-up visit an assessment of potency status was made. Penile structures were defined by a single observer blinded to the potency status, using Web-based, on-line software. The dosimetry for penile structures was calculated at the Quality Assurance Center at Washington University and provided to RTOG Statistical Headquarters to determine whether there was a relationship between dose and impotence. Results: Patients whose median penile dose was ≥52.5 Gy had a greater risk of impotence compared with those receiving <52.5 Gy (p = 0.039). In a multivariate analysis neither age, the dose to the prostate, nor the use of hormonal therapy correlated with the risk of impotence. Conclusions: Dose to the bulb of the penis seems to be associated with the risk of radiation-induced impotence

  14. Stuttering on function words in bilingual children who stutter: A preliminary study.

    Science.gov (United States)

    Gkalitsiou, Zoi; Byrd, Courtney T; Bedore, Lisa M; Taliancich-Klinger, Casey L

    2017-01-01

    Evidence suggests young monolingual children who stutter (CWS) are more disfluent on function than content words, particularly when produced in the initial utterance position. The purpose of the present preliminary study was to investigate whether young bilingual CWS present with this same pattern. The narrative and conversational samples of four bilingual Spanish- and English-speaking CWS were analysed. All four bilingual participants produced significantly more stuttering on function words compared to content words, irrespective of their position in the utterance, in their Spanish narrative and conversational speech samples. Three of the four participants also demonstrated more stuttering on function compared to content words in their narrative speech samples in English, but only one participant produced more stuttering on function than content words in her English conversational sample. These preliminary findings are discussed relative to linguistic planning and language proficiency and their potential contribution to stuttered speech.

  15. A preliminary study on the CT finding in SARS following hospital discharge

    International Nuclear Information System (INIS)

    Zhang Lieguang; Liu Jinxing; Chen Bihua; Jiang Songfeng

    2004-01-01

    Objective: To study the CT finding of chest in patient with SARS following hospital discharge. Methods: Thirty-six patients (11 men, 25 women; age range, 20-73 years; mean age, 39 years) with confirmed SARS underwent follow-up spiral CT. The scans were obtained on average 187 days (range from 152 days to 225 days) after onset of symptoms. Patients were assigned to group 1 (with heavy SARS, n=19) and group 2 (with common SARS, n=17) for analysis. The chest X-ray films of the 36 patients in fastigium of film were retrospectively reviewed. Results: 58.33% (21 of 36) cases are normal on the CT of thorax. In group 1 42.11% (8 of 19) cases and in group 2 76.47%(13 of 17) cases. In group 1: 31.58%(6 of 19) cases present diffuse ground-glass opacification, 21.05% (4 of 19) cases present multi-patch ground-glass opacification, 5.26% (1 of 19) cases present local ground-glass opacification in single lobar, 31.58% (6 of 19) cases present intralobular interstitial thickening and/or interlobular septal thickening, 5.26% (1 of 19) present subpleural lines, 5.26% (1 of 19) present honeycombing, 5.26% (1 of 19) cases present bullae; In group 2: 11.76% (2 of 17) cases present local ground-glass opacification, 11.76%(2 of 17) cases present intralobular interstitial thickening and/or interlobular septal thickening, 5.88%(1 of 17) cases present organized pneumonia. In group 1, 73.68% (14/19) cases in fastigium of film present large areas of lung consolidation and diffuse ground-glass opacification. Conclusion: Most of the healing SARS cases after certain time are normal on the CT finding of thorax. Part of them remain manifests such as ground-glass opacification, intralobular interstitial thickening and/or interlobular septal thickening, subpleural lines, honeycombing, traction bronchiectasis, organized pneumonia and bullae. They relate to severeness of the lesion of the lung in fastigium of film. Such finding can last for long time and probably fibrosis can be developed. (authors)

  16. An experimental study on total dose effects in SRAM-based FPGAs

    International Nuclear Information System (INIS)

    Yao Zhibin; He Baoping; Zhang Fengqi; Guo Hongxia; Luo Yinhong; Wang Yuanming; Zhang Keying

    2009-01-01

    In order to study testing methods and find sensitive parameters in total dose effects on SRAM-based FPGA, XC2S100 chips were irradiated by 60 Co γ-rays and tested with two test circuit designs. By analyzing the experimental results, the test flow of configuration RAM and bock RAM was given, and the most sensitive parameter was obtained. The results will be a solid foundation for establishing test specification and evaluation methods of total dose effects on SRAM-based FPGAs. (authors)

  17. The Leu72Met Polymorphism of the Prepro-ghrelin Gene is Associated With Alcohol Consumption and Subjective Responses to Alcohol: Preliminary Findings.

    Science.gov (United States)

    Suchankova, Petra; Yan, Jia; Schwandt, Melanie L; Stangl, Bethany L; Jerlhag, Elisabet; Engel, Jörgen A; Hodgkinson, Colin A; Ramchandani, Vijay A; Leggio, Lorenzo

    2017-07-01

    The orexigenic peptide ghrelin may enhance the incentive value of food-, drug- and alcohol-related rewards. Consistent with preclinical findings, human studies indicate a role of ghrelin in alcohol use disorders (AUD). In the present study an a priori hypothesis-driven analysis was conducted to investigate whether a Leu72Met missense polymorphism (rs696217) in the prepro-ghrelin gene (GHRL), is associated with AUD, alcohol consumption and subjective responses to alcohol. Association analysis was performed using the National Institute on Alcohol Abuse and Alcoholism (NIAAA) clinical sample, comprising AUD individuals and controls (N = 1127). Then, a post-hoc analysis using data from a human laboratory study of intravenous alcohol self-administration (IV-ASA, N = 144) was performed to investigate the association of this SNP with subjective responses following a fixed dose of alcohol (priming phase) and alcohol self-administration (ad libitum phase). The case-control study revealed a trend association (N = 1127, OR = 0.665, CI = 0.44-1.01, P = 0.056) between AUD diagnosis and Leu72Met. In AUD subjects, the SNP was associated with significantly lower average drinks per day (n = 567, β = -2.49, 95% CI = -4.34 to -0.64, P = 0.008) and significantly fewer heavy drinking days (n = 567, β = -12.00, 95% CI = -19.10 to -4.89, P polymorphism in the prepro-ghrelin gene, is associated with alcohol use disorder, alcohol consumption and subjective responses to alcohol. Although preliminary, results suggest that the Leu72Leu genotype may lead to increased risk of alcohol use disorder possibly via mechanisms involving a lower response to alcohol. Medical Council on Alcohol and Oxford University Press 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  18. Radiocesium and polonium in seals from the Baltic Sea. A preliminary study; Radiocaesium och polonium i sael fran Oestersjoen, en preliminaer studie

    Energy Technology Data Exchange (ETDEWEB)

    Holm, E. [Risoe National Lab., Roskilde (Denmark); Leisvik, M. [Lunds Univ., Avd. foer Radiofysik, Lund (Sweden)

    2002-04-01

    {sup 137}Cs and {sup 210}Po in muscle, liver and kidney from 5 seals from the Baltic Sea have been studied. Assuming that the seals consume 5% of their own body weight each day and by using previously obtained data for the doses in fish, the biological half time has been estimated to 20 days for Cesium and 35 days for Polonium. The maximum yearly doses are calculated to 76 {mu}Gy from {sup 137}CS to muscle and 3 500 {mu}Gy to kidneys from {sup 210}Po. These data are very preliminary, the number of individuals being so small, and it is difficult to estimate how much food other than fish the seals consume. Furthermore only few data for radioactive concentrations in whole fish exist, which especially impacts the results for Polonium. (LN)

  19. Low-Dose and Standard-Dose Unenhanced Helical Computed Tomography for the Assessment of Acute Renal Colic: Prospective Comparative Study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Soo; Hwang, Im Kyung; Choi, Yo Won; Namkung, Sook; Kim, Heung Cheol; Hwang, Woo Cheol; Choi, Kuk Myung; Park, Ji Kang; Han, Tae Il; Kang, Weechang [Cheju National Univ. College of Medicine, Jeju (Korea, Republic of). Dept. of Diagnostic Radiology

    2005-11-01

    Purpose: To compare the efficacy of low-dose and standard-dose computed tomography (CT) for the diagnosis of ureteral stones. Material and Methods: Unenhanced helical CT was performed with both a standard dose (260 mAs, pitch 1.5) and a low dose (50 mAs, pitch 1.5) in 121 patients suspected of having acute renal colic. The two studies were prospectively and independently interpreted for the presence and location of ureteral stones, abnormalities unrelated to stone disease, identification of secondary signs, i.e. hydronephrosis and perinephric stranding, and tissue rim sign. The standard-dose CT images were interpreted by one reviewer and the low-dose CT images independently by two reviewers unaware of the standard-dose CT findings. The findings of the standard and low-dose CT scans were compared with the exact McNemar test. Interobserver agreements were assessed with kappa analysis. The effective radiation doses resulting from two different protocols were calculated by means of commercially available software to which the Monte-Carlo phantom model was given. Results: The sensitivity, specificity, and accuracy of standard-dose CT for detecting ureteral stones were 99%, 93%, and 98%, respectively, whereas for the two reviewers the sensitivity of low-dose CT was 93% and 95%, specificity 86%, and accuracy 92% and 94%. We found no significant differences between standard-dose and low-dose CT in the sensitivity and specificity for diagnosing ureter stones ( P >0.05 for both). However, the sensitivity of low-dose CT for detection of 19 stones less than or equal to 2 mm in diameter was 79% and 68%, respectively, for the two reviewers. Low-dose CT was comparable to standard-dose CT in visualizing hydronephrosis and the tissue rim sign. Perinephric stranding was far less clear on low-dose CT. Low-dose CT had the same diagnostic performance as standard-dose CT in diagnosing alternative diseases. Interobserver agreement between the two low-dose CT reviewers in the diagnosis of

  20. Radiation dose measurement in gastrointestinal studies

    International Nuclear Information System (INIS)

    Sulieman, A.; Elzaki, M.; Kappas, C.; Theodorou, K.

    2011-01-01

    Barium studies investigations (barium swallow, barium meal and barium enema) are the basic routine radiological examination, where barium sulphate suspension is introduced to enhance image contrast of gastrointestinal tracts. The aim of this study was to quantify the patients' radiation doses during barium studies and to estimate the organ equivalent dose and effective dose with those procedures. A total of 33 investigations of barium studies were measured by using thermoluminescence dosemeters. The result showed that the patient entrance surface doses were 12.6±10, 44.5±49 and 35.7±50 mGy for barium swallow, barium meal, follow through and enema, respectively. Effective doses were 0.2, 0.35 and 1.4 mSv per procedure for barium swallow, meal and enema respectively. Radiation doses were comparable with the previous studies. A written protocol for each procedure will reduce the inter-operator variations and will help to reduce unnecessary exposure. (authors)

  1. Attachment and Aggressive Manifestations in Younger Adulthood - "Preliminary Findings"

    Directory of Open Access Journals (Sweden)

    Tatiana Lorincová

    2014-07-01

    Full Text Available The main topic of the contribution was comparison between retrospective attachment (emocional warmth and rejection and aggressive manifestations (physical aggressivness, verbal aggressivness, anger and hostility among younger adulthood. Bowlby's theory of attachment was that once a core attachment style develops in an infant, it will influence and shape the nature of all intimate relations for the individual moving forward throughout the infant's life cycle. Authors Mikulincer and Shaver (2011 explain how these primary attachment experiences would affect future emotional, cognitive and behavioral processes. Secure adolescents, in comparison to insecure ones are perceived as being less aggressive. Research has pointed out that secure parental attachment promotes adaptive psychological functioning. The direct relationship between attachment security and aggressive/delinquent behaviour is in line with prior evidence that secure adolescents rate higher in terms of emotional and social adjustment, enjoy more positive relationships with their family and peers, and are less likely to engage in externalizing problems, such as antisocial and aggressive behaviours. On the other hand, insecure attachment is connected with aggressive and externalizing behaviour. Hypotheses were formulated on the base of theoretical background and our assumption was, that younger adults with emocional warmth attachment will have lower level of aggressive manifestations (physical aggression, verbal aggression, anger and hostility than younger adults with rejectional attachment. We used two standardized questionnaires for data collection, s.E.M.B.U. Questionnaire, which measured retrospective attachment (emocional warmth and rejection and Questionnaire of Aggressivness, which measured aggressive manifestations. We used statistical analysis and we found statistically significant differencies, which are preliminary findings from broader research, between emocional warmth

  2. Preliminary Study on a Cylindrical Ambient Dose-equivalent Chamber%圆柱形周围剂量当量电离室的初步研究

    Institute of Scientific and Technical Information of China (English)

    李德红; 杨健; 邬蒙蒙; 李兴东; 杨元第

    2013-01-01

    根据国际辐射单位和测量委员会(ICRU)报告中对环境监测中新的实用辐射量定义,对一种圆柱形周围剂量当量电离室进行了初步研究.结果表明在正常工作条件下,收集极的材料和尺寸对于能量响应的影响并不明显;铝质电离室的能量响应特性好于有机玻璃的电离室.可以考虑同时采用有机玻璃和铝作为制作电离室的材料,通过理论计算并优化几何尺寸得到较好的能量响应曲线.%According to definitions of the new operational radiation quantities for area monitoring recommended by the International Commission on Radiation Units and Measurements (ICRU) report,a cylindrical ambient dose equivalent ionization chamber is designed and preliminary studied.The results show that the effect by the material and the size of the collector to the energy response is not obvious,energy response characteristic of the aluminum ionization chamber is better than that of the plexiglass.Through the theoretical calculation and geometry optimization,the cylindrical ambient dose equivalent ionization chamber made from ptexiglass as a shell and lined with an appropriate thickness of the aluminum layer will get a better energy response curve.

  3. Studies of health effects of low dose radiation and its application to medicare

    International Nuclear Information System (INIS)

    Yamaoka, Kiyonori; Ishida, Kenji; Iwasaki, Toshiyasu; Koana, Takao; Magae, Junji; Watanabe, Masami; Sakamoto, Kiyohiko

    2008-01-01

    The articles contain following 7 topics of low dose radiation effects. Studies of Health Effects of Low dose Radiation and Its Application to Medicare'', describes the indication of Rn therapy and investigations of its usefulness mechanism mainly in Misasa Spa, Okayama Pref. ''Challenges for the Paradigm Shift (CRIEPI Studies)'', introduces studies against the paradigm that radiation dose is linearly and proportionally hazardous. ''Studies of High Background Radiation Area (CRIEPI Studies)'', describes global HBRA studies on chromosome affection and effect of smoking in HBRA. ''Is the Radiation Effect on Man Proportional to Dose? (CRIEPI Studies)'', describes studies of immature sperm irradiated at low dose against Linear-Non-threshold Theory (LNT) hypothesis. ''Induction of Radiation Resistance by Low Dose Radiation and Assessment of Its Effect in Models of Human Diseases (CRIEPI Studies)'', explains the adoptive response in radiation effect, suppression of carcinogenesis and immune regulation by previous low dose radiation in the mouse, and improvement of diabetes in the db/db mouse. ''Modulation of Biological Effects of Low Dose Radiation: Adoptive Response, Bystander Effect, Genetic Instability and Radiation Hormesis'', summarizes findings of each item. ''Cancer Treatment with Low dose Radiation to the Whole Body'', describes basic studies in the mouse tumor in relation to suppression of carcinogenesis and metastasis, immune activation and treatment, and successful clinical studies in patients with ovary, colon cancers and malignant lymphoma where survival has been significantly improved: a base of recent European Organization for Research and Treatment of Cancer (EORTC) clinical trials. The mechanism is essentially based on immune activation of patients to cure the disease. (R.T.)

  4. Nevada potential repository preliminary transportation strategy Study 2. Volume 1

    International Nuclear Information System (INIS)

    1996-02-01

    The objectives of this study were to build on the findings of the Nevada Potential Repository Preliminary Transportation Strategy Study 1 (CRWMS M ampersand O 1995b), and to provide additional information for input to the repository environmental impact statement (EIS) process. In addition, this study supported the future selection of a preferred rail corridor and/or heavy haul route based on defensible data, methods, and analyses. Study research did not consider proposed legislation. Planning was conducted according to the Civilian Radioactive Waste Management Program Plan (DOE 1994a). The specific objectives of Study 2 were to: eliminate or reduce data gaps, inconsistencies, and uncertainties, and strengthen the analysis performed in Study 1; develop a preliminary list of rail route evaluation criteria that could be used to solicit input from stakeholders during scoping meetings. The evaluation criteria will be revised based on comments received during scoping; restrict and refine the width of the four rail corridors identified in Study 1 to five miles or less, based on land use constraints and engineering criteria identified and established in Study 2; evaluate national-level effects of routing spent nuclear fuel and high-level waste to the four identified branch lines, including the effects of routing through or avoiding Las Vegas; continue to gather published land use information and environmental data to support the repository EIS; continue to evaluate heavy haul truck transport over three existing routes as an alternative to rail and provide sufficient information to support the repository EIS process; and evaluate secondary uses for rail (passenger use, repository construction, shared use)

  5. MR evaluation of renal function. A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Beomonte Zobel, B; Giammarile, F; Matarese, A; Gallucci, M; Mascicchi, C; Passariello, R; Di Renzi, P; Splendiani, G; Casciani, C U

    1988-01-01

    The amount of functioning renal parenchyma can be estimated by MRI by considering the ratio between the mean intensities of cortical and medullar zones of the kidney. Fifty-six patients and 5 healthy volunteers were studied by MRI in our department. Scanning was performed with a superconductive magnet system operating at 0.5 Tesla. Pulse sequence was Spin-Echo with TR 300/TE 30 ms. The cortimedullary ratio (CMR) and differentiation (CMD) were standardized and related with creatine blood levels. CMR data ranged from 1.05 to 3.00, while CMD data ranged from 0.04 to 0.50. High values (good cortico-medullary contrast) were observed in subjects with normal renal function. Patients with renal diseases had low CMR and CMD, proportionally to the degree of renal failure, as proved by laboratory findings. Our preliminary study seems to demonstrate that MRI is an useful technique in the follow-up of patients with chronic renal disease. 19 refs.

  6. Study of feasibility of detecting effects of low-dose radiation in shipyard workers. Final report, May 15-August 15, 1978

    International Nuclear Information System (INIS)

    Matanoski, G.M.

    1982-12-01

    There is very little information available on the chronic health effects from repeated low-level doses of radiation. This study examines the adequacy of determining radiation exposure doses in shipyard workers, the procedures used in the radiation control programs, and the feasibility of establishing an appropriate population of nuclear and non-nuclear shipyard workers for long-term studies of low-level radiation. The availability of records and the methods of population identification and of measurement of radiation dose were determined during initial visits to the yards. Personnel, industrial hygiene, radiation and medical records were examined for suitability, completeness and accuracy. It was necessary to assure that no possible errors or omissions in personnel and radiation records existed in order that the final data will have validity. Preliminary investigations on the methods of follow-up in the Portsmouth population and the time required for each procedure were also undertaken in order to have a better estimate of the total cost for a long term study

  7. Effects of climate change on Pacific Northwest water-related resources: Summary of preliminary findings

    Energy Technology Data Exchange (ETDEWEB)

    Scott, M.J.; Sands, R.D.; Vail, L.W.; Chatters, J.C.; Neitzel, D.A.; Shankle, S.A.

    1993-12-01

    The Pacific Northwest Case Study is a multi-agency analysis of atmospheric/climatic change impacts on the Pacific Northwest (which includes Washington, Oregon, Idaho, and portions of the Columbia River Basin in Western Montana). The purpose of the case study, which began in fiscal year 1991, was to develop and test analytical tools, as well as to develop an assessment of the effects of climate change on climate-sensitive natural resources of the Pacific Northwest and economic sectors dependent on them. The overall study, jointly funded by the US Department of Energy (DOE) and the US Environmental Protection Agency, was a broad-based, reconnaissance-level study to identify potential climate impacts on agriculture, coastal resources, forest resources, and irrigation in the Pacific Northwest. DOE participated in the reconnaissance study, with responsibility for hydroelectric and water supply issues. While this report briefly discusses a broader array of water issues, attention is mainly focused on three aspects of the water study: (1) the effects of the region`s higher temperatures on the demand for electric power (which in turn puts additional demand on hydroelectric resources of the region); (2) the effects of higher temperatures and changes, both in precipitation amounts and seasonality, on river flows and hydroelectric supply; and (3) the effect of higher temperatures and changed precipitation amounts and seasonality on salmonid resources -- particularly the rearing conditions in tributaries of the Columbia River Basin. Because the meaning of regional climate forecasts is still quite uncertain, most of the preliminary findings are based on sensitivity analyses and historical analog climate scenarios.

  8. Integration of models for the Hanford Environmental Dose Reconstruction Project

    International Nuclear Information System (INIS)

    Napier, B.A.

    1991-01-01

    The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation dose that individuals could have received as a result of emissions from nuclear operations at Hanford since 1944. The objective of phase 1 of the project was to demonstrate through calculations that adequate models and support data exist or could be developed to allow realistic estimations of doses to individuals from releases of radionuclides to the environment that occurred as long as 45 years ago. Much of the data used in phase 1 was preliminary; therefore, the doses calculated must be considered preliminary approximations. This paper describes the integration of various models that was implemented for initial computer calculations. Models were required for estimating the quantity of radioactive material released, for evaluating its transport through the environment, for estimating human exposure, and for evaluating resultant doses

  9. High-dose-rate brachytherapy as monotherapy delivered in two fractions within one day for favorable/intermediate-risk prostate cancer: preliminary toxicity data.

    Science.gov (United States)

    Ghilezan, Michel; Martinez, Alvaro; Gustason, Gary; Krauss, Daniel; Antonucci, J Vito; Chen, Peter; Fontanesi, James; Wallace, Michelle; Ye, Hong; Casey, Alyse; Sebastian, Evelyn; Kim, Leonard; Limbacher, Amy

    2012-07-01

    To report the toxicity profile of high-dose-rate (HDR)-brachytherapy (BT) as monotherapy in a Human Investigation Committee-approved study consisting of a single implant and two fractions (12 Gy × 2) for a total dose of 24 Gy, delivered within 1 day. The dose was subsequently increased to 27 Gy (13.5 Gy × 2) delivered in 1 day. We report the acute and early chronic genitourinary and gastrointestinal toxicity. A total of 173 patients were treated between December 2005 and July 2010. However, only the first 100 were part of the IRB-approved study and out of these, only 94 had a minimal follow-up of 6 months, representing the study population for this preliminary report. All patients had clinical Stage T2b or less (American Joint Committee on Cancer, 5th edition), Gleason score 6-7 (3+4), and prostate-specific antigen level of ≤12 ng/mL. Ultrasound-guided HDR-BT with real-time dosimetry was used. The prescription dose was 24 Gy for the first 50 patients and 27 Gy thereafter. The dosimetric goals and constraints were the same for the two dose groups. Toxicity was scored using the National Cancer Institute Common Terminology Criteria for Adverse Events, version 3. The highest toxicity scores encountered at any point during follow-up are reported. The median follow-up was 17 months (range, 6-40.5). Most patients had Grade 0-1 acute toxicity. The Grade 2 acute genitourinary toxicity was mainly frequency/urgency (13%), dysuria (5%), hematuria, and dribbling/hesitancy (2%). None of the patients required a Foley catheter at any time; however, 8% of the patients experienced transient Grade 1 diarrhea. No other acute gastrointestinal toxicities were found. The most common chronic toxicity was Grade 2 urinary frequency/urgency in 16% of patients followed by dysuria in 4% of patients; 2 patients had Grade 2 rectal bleeding and 1 had Grade 4, requiring laser treatment. Favorable-risk prostate cancer patients treated with a single implant HDR-BT to 24-27 Gy in two fractions

  10. High-Dose-Rate Brachytherapy as Monotherapy Delivered in Two Fractions Within One Day for Favorable/Intermediate-Risk Prostate Cancer: Preliminary Toxicity Data

    Energy Technology Data Exchange (ETDEWEB)

    Ghilezan, Michel, E-mail: mghilezan@beaumont.edu [Department of Radiation Oncology, William Beaumont Hospital and Rose Cancer Institute, Royal Oak, Michigan (United States); Martinez, Alvaro; Gustason, Gary; Krauss, Daniel; Antonucci, J. Vito; Chen, Peter; Fontanesi, James; Wallace, Michelle; Ye Hong; Casey, Alyse; Sebastian, Evelyn; Kim, Leonard; Limbacher, Amy [Department of Radiation Oncology, William Beaumont Hospital and Rose Cancer Institute, Royal Oak, Michigan (United States)

    2012-07-01

    Purpose: To report the toxicity profile of high-dose-rate (HDR)-brachytherapy (BT) as monotherapy in a Human Investigation Committee-approved study consisting of a single implant and two fractions (12 Gy Multiplication-Sign 2) for a total dose of 24 Gy, delivered within 1 day. The dose was subsequently increased to 27 Gy (13.5 Gy Multiplication-Sign 2) delivered in 1 day. We report the acute and early chronic genitourinary and gastrointestinal toxicity. Methods and Materials: A total of 173 patients were treated between December 2005 and July 2010. However, only the first 100 were part of the IRB-approved study and out of these, only 94 had a minimal follow-up of 6 months, representing the study population for this preliminary report. All patients had clinical Stage T2b or less (American Joint Committee on Cancer, 5th edition), Gleason score 6-7 (3+4), and prostate-specific antigen level of {<=}12 ng/mL. Ultrasound-guided HDR-BT with real-time dosimetry was used. The prescription dose was 24 Gy for the first 50 patients and 27 Gy thereafter. The dosimetric goals and constraints were the same for the two dose groups. Toxicity was scored using the National Cancer Institute Common Terminology Criteria for Adverse Events, version 3. The highest toxicity scores encountered at any point during follow-up are reported. Results: The median follow-up was 17 months (range, 6-40.5). Most patients had Grade 0-1 acute toxicity. The Grade 2 acute genitourinary toxicity was mainly frequency/urgency (13%), dysuria (5%), hematuria, and dribbling/hesitancy (2%). None of the patients required a Foley catheter at any time; however, 8% of the patients experienced transient Grade 1 diarrhea. No other acute gastrointestinal toxicities were found. The most common chronic toxicity was Grade 2 urinary frequency/urgency in 16% of patients followed by dysuria in 4% of patients; 2 patients had Grade 2 rectal bleeding and 1 had Grade 4, requiring laser treatment. Conclusions: Favorable

  11. High-Dose-Rate Brachytherapy as Monotherapy Delivered in Two Fractions Within One Day for Favorable/Intermediate-Risk Prostate Cancer: Preliminary Toxicity Data

    International Nuclear Information System (INIS)

    Ghilezan, Michel; Martinez, Alvaro; Gustason, Gary; Krauss, Daniel; Antonucci, J. Vito; Chen, Peter; Fontanesi, James; Wallace, Michelle; Ye Hong; Casey, Alyse; Sebastian, Evelyn; Kim, Leonard; Limbacher, Amy

    2012-01-01

    Purpose: To report the toxicity profile of high-dose-rate (HDR)-brachytherapy (BT) as monotherapy in a Human Investigation Committee-approved study consisting of a single implant and two fractions (12 Gy × 2) for a total dose of 24 Gy, delivered within 1 day. The dose was subsequently increased to 27 Gy (13.5 Gy × 2) delivered in 1 day. We report the acute and early chronic genitourinary and gastrointestinal toxicity. Methods and Materials: A total of 173 patients were treated between December 2005 and July 2010. However, only the first 100 were part of the IRB-approved study and out of these, only 94 had a minimal follow-up of 6 months, representing the study population for this preliminary report. All patients had clinical Stage T2b or less (American Joint Committee on Cancer, 5th edition), Gleason score 6-7 (3+4), and prostate-specific antigen level of ≤12 ng/mL. Ultrasound-guided HDR-BT with real-time dosimetry was used. The prescription dose was 24 Gy for the first 50 patients and 27 Gy thereafter. The dosimetric goals and constraints were the same for the two dose groups. Toxicity was scored using the National Cancer Institute Common Terminology Criteria for Adverse Events, version 3. The highest toxicity scores encountered at any point during follow-up are reported. Results: The median follow-up was 17 months (range, 6–40.5). Most patients had Grade 0-1 acute toxicity. The Grade 2 acute genitourinary toxicity was mainly frequency/urgency (13%), dysuria (5%), hematuria, and dribbling/hesitancy (2%). None of the patients required a Foley catheter at any time; however, 8% of the patients experienced transient Grade 1 diarrhea. No other acute gastrointestinal toxicities were found. The most common chronic toxicity was Grade 2 urinary frequency/urgency in 16% of patients followed by dysuria in 4% of patients; 2 patients had Grade 2 rectal bleeding and 1 had Grade 4, requiring laser treatment. Conclusions: Favorable-risk prostate cancer patients treated with

  12. Alternative Health Care Practitioners in a Chinese American Community: A Preliminary Report of Findings.

    Science.gov (United States)

    Kao, Jessica Ching-Yi

    This paper provides a brief review of the literature on traditional Chinese medicine in both China and the United States and presents observations from a preliminary study of Chinese practitioners in the Chinatown section of Los Angeles, California. The dualistic health care system in Chinese culture is described as comprising both scholarly and…

  13. Report on the preliminary fact finding mission following the accident at the nuclear fuel processing facility in Tokaimura, Japan

    International Nuclear Information System (INIS)

    1999-01-01

    Following the accident on 30 September 1999 at the nuclear fuel processing facility at Tokaimura, Japan, the IAEA Emergency Response Centre received numerous requests for information about the event's causes and consequences from Contact Points under the Conventions on Early Notification of a Nuclear Accident and on Assistance in the Case of a Nuclear Accident or Radiological Emergency. Although the lack of transboundary consequences of the accident meant that action under the Early Notification Convention was not triggered, the Emergency Response Centre issued several advisories to Member States which drew on official reports received from Japan. After discussions with the Government of Japan, the IAEA dispatched a team of three experts from the Secretariat on a fact finding mission to Tokaimura from 13 to 17 October 1999. The present preliminary report by that team documents key technical information obtained during the mission. At this stage, the report can in no way provide conclusive judgements on the causes and consequences of the accident. Investigations are proceeding in Japan and more information is expected to be made available after access has been gained to the building where the accident occurred. Moreover, much of the information already made available will be revised as more accurate assessments are made, for example of the radiation doses to the three individuals who received the highest exposures. Notwithstanding the preliminary nature of this report, it is clear that the accident was not one involving widespread contamination of the environment as in the 1986 Chernobyl accident. Although there was little risk off the site once the accident had been brought under control, the authorities evacuated the population living within a few hundred metres and advised people within about 10 km of the facility to take shelter for a period of about one day. The event at Tokaimura was nevertheless a serious industrial accident. The results of the detailed

  14. Sources of variability in OSL dose measurements using single grains of quartz

    DEFF Research Database (Denmark)

    Thomsen, Kristina Jørkov; Murray, A.S.; Bøtter-Jensen, L.

    2005-01-01

    spread. In this preliminary study, dose distributions have been studied using single grains of heated and laboratory irradiated quartz. By heating the sample, the contribution from incomplete zeroing was excluded and at the same time the sample was sensitised. The laboratory gamma irradiation...

  15. A Brief Report: Lessons Learned and Preliminary Findings of Progreso en Salud, an HIV Risk Reduction Intervention for Latina Seasonal Farmworkers.

    Science.gov (United States)

    Kanamori, Mariano; De La Rosa, Mario; Diez, Stephanie; Weissman, Jessica; Trepka, Mary Jo; Sneij, Alicia; Schmidt, Peter; Rojas, Patria

    2016-12-30

    Throughout the past decade, HIV rates in Florida-particularly South Florida, where many Latina seasonal farmworkers reside and work-have ranked among the highest in the nation. In this brief report, we delineate important lessons learned and preliminary findings from the implementation of the HIV prevention intervention Progreso en Salud (Progress in Health). Among the 114 Latina seasonal farmworker participants, there were significant increases from baseline to 6-month follow-up in the percentages of overall condom use, HIV testing, HIV/AIDS-related communications with friends, HIV knowledge, condom use self-efficacy, and correct use of condoms. Lessons learned from this study can be used to inform future HIV intervention strategies to improve the adoption and maintenance of HIV risk reduction behaviors among high-risk Latina seasonal workers and other high-risk underserved populations. Future research is needed to support our findings.

  16. Favorable Preliminary Outcomes for Men With Low- and Intermediate-risk Prostate Cancer Treated With 19-Gy Single-fraction High-dose-rate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Krauss, Daniel J., E-mail: dkrauss@beaumont.edu [Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States); Ye, Hong [Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States); Martinez, Alvaro A. [21st Century Oncology, Farmington Hills, Michigan (United States); Mitchell, Beth; Sebastian, Evelyn; Limbacher, Amy; Gustafson, Gary S. [Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States)

    2017-01-01

    Purpose: To report the toxicity and preliminary clinical outcomes of a prospective trial evaluating 19-Gy, single-fraction high-dose-rate (HDR) brachytherapy for men with low- and intermediate-risk prostate cancer. Methods and Materials: A total of 63 patients were treated according to an institutional review board-approved prospective study of single-fraction HDR brachytherapy. Eligible patients had tumor stage ≤T2a, prostate-specific antigen level ≤15 ng/mL, and Gleason score ≤7. Patients with a prostate gland volume >50 cm{sup 3} and baseline American Urologic Association symptom score >12 were ineligible. Patients underwent transrectal ultrasound-guided transperineal implantation of the prostate, followed by single-fraction HDR brachytherapy. Treatment was delivered using {sup 192}Ir to a dose of 19 Gy prescribed to the prostate, with no additional margin applied. Results: Of the 63 patients, 58 had data available for analysis. Five patients had withdrawn consent during the follow-up period. The median follow-up period was 2.9 years (range 0.3-5.2). The median age was 61.4 years. The median gland volume at treatment was 34.8 cm{sup 3}. Of the 58 patients, 91% had T1 disease, 71% had Gleason score ≤6 (29% with Gleason score 7), and the median pretreatment prostate-specific antigen level was 5.1 ng/mL. The acute and chronic grade 2 genitourinary toxicity incidence was 12.1% and 10.3%, respectively. No grade 3 urinary toxicity occurred. No patients experienced acute rectal toxicity grade ≥2, and 2 experienced grade ≥2 chronic gastrointestinal toxicity. Three patients experienced biochemical failure, yielding a 3-year cumulative incidence estimate of 6.8%. Conclusions: Single-fraction HDR brachytherapy is well-tolerated, with favorable preliminary biochemical and clinical disease control rates.

  17. Paediatric x-ray radiation dose reduction and image quality analysis.

    Science.gov (United States)

    Martin, L; Ruddlesden, R; Makepeace, C; Robinson, L; Mistry, T; Starritt, H

    2013-09-01

    Collaboration of multiple staff groups has resulted in significant reduction in the risk of radiation-induced cancer from radiographic x-ray exposure during childhood. In this study at an acute NHS hospital trust, a preliminary audit identified initial exposure factors. These were compared with European and UK guidance, leading to the introduction of new factors that were in compliance with European guidance on x-ray tube potentials. Image quality was assessed using standard anatomical criteria scoring, and visual grading characteristics analysis assessed the impact on image quality of changes in exposure factors. This analysis determined the acceptability of gradual radiation dose reduction below the European and UK guidance levels. Chest and pelvis exposures were optimised, achieving dose reduction for each age group, with 7%-55% decrease in critical organ dose. Clinicians confirmed diagnostic image quality throughout the iterative process. Analysis of images acquired with preliminary and final exposure factors indicated an average visual grading analysis result of 0.5, demonstrating equivalent image quality. The optimisation process and final radiation doses are reported for Carestream computed radiography to aid other hospitals in minimising radiation risks to children.

  18. Paediatric x-ray radiation dose reduction and image quality analysis

    International Nuclear Information System (INIS)

    Martin, L; Ruddlesden, R; Mistry, T; Starritt, H; Makepeace, C; Robinson, L

    2013-01-01

    Collaboration of multiple staff groups has resulted in significant reduction in the risk of radiation-induced cancer from radiographic x-ray exposure during childhood. In this study at an acute NHS hospital trust, a preliminary audit identified initial exposure factors. These were compared with European and UK guidance, leading to the introduction of new factors that were in compliance with European guidance on x-ray tube potentials. Image quality was assessed using standard anatomical criteria scoring, and visual grading characteristics analysis assessed the impact on image quality of changes in exposure factors. This analysis determined the acceptability of gradual radiation dose reduction below the European and UK guidance levels. Chest and pelvis exposures were optimised, achieving dose reduction for each age group, with 7%–55% decrease in critical organ dose. Clinicians confirmed diagnostic image quality throughout the iterative process. Analysis of images acquired with preliminary and final exposure factors indicated an average visual grading analysis result of 0.5, demonstrating equivalent image quality. The optimisation process and final radiation doses are reported for Carestream computed radiography to aid other hospitals in minimising radiation risks to children. (paper)

  19. SU-F-R-39: Effects of Radiation Dose Reduction On Renal Cell Carcinoma Discrimination Using Multi-Phasic CT Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wahi-Anwar, M; Young, S; Lo, P; Raman, S; Kim, H; Brown, M; McNitt-Gray, M; Coy, H; Ashen-Garry, D; Pace-Soler, E [UCLA School of Medicine, Los Angeles, CA (United States)

    2016-06-15

    Purpose: A method to discriminate different types of renal cell carcinoma (RCC) was developed using attenuation values observed in multiphasic contrast-enhanced CT. This work evaluates the sensitivity of this RCC discrimination task at different CT radiation dose levels. Methods: We selected 5 cases of kidney lesion patients who had undergone four-phase CT scans covering the abdomen to the lilac crest. Through an IRB-approved study, the scans were conducted on 64-slice CT scanners (Definition AS/Definition Flash, Siemens Healthcare) using automatic tube-current modulation (TCM). The protocol included an initial baseline unenhanced scan, followed by three post-contrast injection phases. CTDIvol (32 cm phantom) measured between 9 to 35 mGy for any given phase. As a preliminary study, we limited the scope to the cortico-medullary phase—shown previously to be the most discriminative phase. A previously validated method was used to simulate a reduced dose acquisition via adding noise to raw CT sinogram data, emulating corresponding images at simulated doses of 50%, 25%, and 10%. To discriminate the lesion subtype, ROIs were placed in the most enhancing region of the lesion. The mean HU value of an ROI was extracted and used to discriminate to the worst-case RCC subtype, ranked in the order of clear cell, papillary, chromophobe and the benign oncocytoma. Results: Two patients exhibited a change of worst case RCC subtype between original and simulated scans, at 25% and 10% doses. In one case, the worst-case RCC subtype changed from oncocytoma to chromophobe at 10% and 25% doses, while the other case changed from oncocytoma to clear cell at 10% dose. Conclusion: Based on preliminary results from an initial cohort of 5 patients, worst-case RCC subtypes remained constant at all simulated dose levels except for 2 patients. Further study conducted on more patients will be needed to confirm our findings. Institutional research agreement, Siemens Healthcare; Past recipient

  20. SU-F-R-39: Effects of Radiation Dose Reduction On Renal Cell Carcinoma Discrimination Using Multi-Phasic CT Imaging

    International Nuclear Information System (INIS)

    Wahi-Anwar, M; Young, S; Lo, P; Raman, S; Kim, H; Brown, M; McNitt-Gray, M; Coy, H; Ashen-Garry, D; Pace-Soler, E

    2016-01-01

    Purpose: A method to discriminate different types of renal cell carcinoma (RCC) was developed using attenuation values observed in multiphasic contrast-enhanced CT. This work evaluates the sensitivity of this RCC discrimination task at different CT radiation dose levels. Methods: We selected 5 cases of kidney lesion patients who had undergone four-phase CT scans covering the abdomen to the lilac crest. Through an IRB-approved study, the scans were conducted on 64-slice CT scanners (Definition AS/Definition Flash, Siemens Healthcare) using automatic tube-current modulation (TCM). The protocol included an initial baseline unenhanced scan, followed by three post-contrast injection phases. CTDIvol (32 cm phantom) measured between 9 to 35 mGy for any given phase. As a preliminary study, we limited the scope to the cortico-medullary phase—shown previously to be the most discriminative phase. A previously validated method was used to simulate a reduced dose acquisition via adding noise to raw CT sinogram data, emulating corresponding images at simulated doses of 50%, 25%, and 10%. To discriminate the lesion subtype, ROIs were placed in the most enhancing region of the lesion. The mean HU value of an ROI was extracted and used to discriminate to the worst-case RCC subtype, ranked in the order of clear cell, papillary, chromophobe and the benign oncocytoma. Results: Two patients exhibited a change of worst case RCC subtype between original and simulated scans, at 25% and 10% doses. In one case, the worst-case RCC subtype changed from oncocytoma to chromophobe at 10% and 25% doses, while the other case changed from oncocytoma to clear cell at 10% dose. Conclusion: Based on preliminary results from an initial cohort of 5 patients, worst-case RCC subtypes remained constant at all simulated dose levels except for 2 patients. Further study conducted on more patients will be needed to confirm our findings. Institutional research agreement, Siemens Healthcare; Past recipient

  1. Dataset for Phase I randomized clinical trial for safety and tolerability of GET 73 in single and repeated ascending doses including preliminary pharmacokinetic parameters

    Directory of Open Access Journals (Sweden)

    Carolina L. Haass-Koffler

    2017-12-01

    Full Text Available The data in this article outline the methods used for the administration of GET 73 in the first time-in-human manuscript entitled “Phase I randomized clinical trial for the safety, tolerability and preliminary pharmacokinetics of the mGluR5 negative allosteric modulator GET 73 following single and repeated doses in healthy male volunteers” (Haass-Koffler et al., 2017 [1]. Data sets are provided in two different manners. The first series of tables provided includes procedural information about the experiments conducted. The next series of tables provided includes Pharmacokinetic (PK parameters for GET 73 and its main metabolite MET 2. This set of data is comprised by two experiments: Experiment 1 references a single ascending dose administration of GET 73 and Experiment 2 references a repeated ascending dose administration of GET 73. Keywords: Glutamate receptor subtype 5 (mGlu5, Allosteric modulator, GET 73, Safety, Tolerability

  2. SU-E-T-86: A Systematic Method for GammaKnife SRS Fetal Dose Estimation

    Energy Technology Data Exchange (ETDEWEB)

    Geneser, S; Paulsson, A; Sneed, P; Braunstein, S; Ma, L [UCSF Comprehensive Cancer Center, San Francisco, CA (United States)

    2015-06-15

    Purpose: Estimating fetal dose is critical to the decision-making process when radiation treatment is indicated during pregnancy. Fetal doses less than 5cGy confer no measurable non-cancer developmental risks but can produce a threefold increase in developing childhood cancer. In this study, we estimate fetal dose for a patient receiving Gamma Knife stereotactic radiosurgery (GKSRS) treatment and develop a method to estimate dose directly from plan details. Methods: A patient underwent GKSRS on a Perfexion unit for eight brain metastases (two infratentorial and one brainstem). Dose measurements were performed using a CC13, head phantom, and solid water. Superficial doses to the thyroid, sternum, and pelvis were measured using MOSFETs during treatment. Because the fetal dose was too low to accurately measure, we obtained measurements proximally to the isocenter, fitted to an exponential function, and extrapolated dose to the fundus of the uterus, uterine midpoint, and pubic synthesis for both the preliminary and delivered plans. Results: The R-squared fit for the delivered doses was 0.995. The estimated fetal doses for the 72 minute preliminary and 138 minute delivered plans range from 0.0014 to 0.028cGy and 0.07 to 0.38cGy, respectively. MOSFET readings during treatment were just above background for the thyroid and negligible for all inferior positions. The method for estimating fetal dose from plan shot information was within 0.2cGy of the measured values at 14cm cranial to the fetal location. Conclusion: Estimated fetal doses for both the preliminary and delivered plan were well below the 5cGy recommended limit. Due to Pefexion shielding, internal dose is primarily governed by attenuation and drops off exponentially. This is the first work that reports fetal dose for a GK Perfexion unit. Although multiple lesions were treated and the duration of treatment was long, the estimated fetal dose remained very low.

  3. SU-E-T-86: A Systematic Method for GammaKnife SRS Fetal Dose Estimation

    International Nuclear Information System (INIS)

    Geneser, S; Paulsson, A; Sneed, P; Braunstein, S; Ma, L

    2015-01-01

    Purpose: Estimating fetal dose is critical to the decision-making process when radiation treatment is indicated during pregnancy. Fetal doses less than 5cGy confer no measurable non-cancer developmental risks but can produce a threefold increase in developing childhood cancer. In this study, we estimate fetal dose for a patient receiving Gamma Knife stereotactic radiosurgery (GKSRS) treatment and develop a method to estimate dose directly from plan details. Methods: A patient underwent GKSRS on a Perfexion unit for eight brain metastases (two infratentorial and one brainstem). Dose measurements were performed using a CC13, head phantom, and solid water. Superficial doses to the thyroid, sternum, and pelvis were measured using MOSFETs during treatment. Because the fetal dose was too low to accurately measure, we obtained measurements proximally to the isocenter, fitted to an exponential function, and extrapolated dose to the fundus of the uterus, uterine midpoint, and pubic synthesis for both the preliminary and delivered plans. Results: The R-squared fit for the delivered doses was 0.995. The estimated fetal doses for the 72 minute preliminary and 138 minute delivered plans range from 0.0014 to 0.028cGy and 0.07 to 0.38cGy, respectively. MOSFET readings during treatment were just above background for the thyroid and negligible for all inferior positions. The method for estimating fetal dose from plan shot information was within 0.2cGy of the measured values at 14cm cranial to the fetal location. Conclusion: Estimated fetal doses for both the preliminary and delivered plan were well below the 5cGy recommended limit. Due to Pefexion shielding, internal dose is primarily governed by attenuation and drops off exponentially. This is the first work that reports fetal dose for a GK Perfexion unit. Although multiple lesions were treated and the duration of treatment was long, the estimated fetal dose remained very low

  4. Psychophysiological deficits in young adolescents with psychosis or ADHD: Preliminary findings

    DEFF Research Database (Denmark)

    Rydkjær, Jacob; Jepsen, Jens Richardt Møllegaard; Fagerlund, Birgitte

    add valuable information on how to differentiate premature stages of early onset psychosis from ADHD. Aim: To characterize psychophysiological deficits in young adolescents with psychosis or ADHD and compare the profiles of impariments between the two groups. Materials and methods: A cohort of young...... and low intensity prepulse trials, Mismatch Negativity (MMN), Selective Attention (SA) and P50. Results: Preliminary analyses of 18 patients with psychosis and 12 patients with ADHD showed significantly less PPI in the higher intensity prepulse trials in the psychosis group than in the ADHD group....... No significant group difference was found in the lower intensity prepulse trials. Conclusion: The preliminary results indicate lower levels of PPI in adolescents with early onset psychosis than in young patients with ADHD. If these results hold in the final analyses then this knowledge may contribute to better...

  5. Preliminary study of the charged particle radiaton for th satellite power system

    International Nuclear Information System (INIS)

    Stassinopoulos, E.G.

    1978-01-01

    A preliminary radiation study was performed for the SPS project in order to determine the energetic charged particle environment for the three major phases of an SPS mission: the low earth orbit (LEO), the transfer ellipse (TE), and the synchronous geostationary trajectory (GEO). For that purpose, extensive calculations were performed and a large data base was generated, processeed, and analyzed. The external (surface incident) charged particle intensities, predicted for the SPS in each mission phase, were determined by orbital flux integration from the latest environment models. Magnetic field definitions for the three trajectories were obtained from a current field model. Spatial and temporal variations or conditions were considered and accounted for, where possible. Limited shielding and dose evaluations were performed for a simple geometry. The results of this analysis are presented in tabular and graphical form

  6. Experimental interstellar organic chemistry - Preliminary findings

    Science.gov (United States)

    Khare, B. N.; Sagan, C.

    1973-01-01

    Review of the results of some explicit experimental simulation of interstellar organic chemistry consisting in low-temperature high-vacuum UV irradiation of condensed simple gases known or suspected to be present in the interstellar medium. The results include the finding that acetonitrile may be present in the interstellar medium. The implication of this and other findings are discussed.

  7. Comparison of high dose rate (HDR) and low dose rate (LDR) brachytherapy in the treatment of stage IIIB cervix cancer with radiation therapy alone. The preliminary results

    International Nuclear Information System (INIS)

    Trippe, Nivaldo; Novaes, P.E.; Ferrigno, R.; Pellizzon, A.C.; Salvajoli, J.V.; Fogaroli, R.C.; Maia, M.A.C.; Baraldi, H.E.

    1996-01-01

    Purpose/Objective: To compare the results between HDR and LDR brachytherapy in the treatment of stage IIIB cervix cancer with radiation therapy alone through a prospective and randomized trial. Materials and Methods: From September 1992 to December 1993, 65 patients with stage IIIB cervical cancer were randomized to one of the following treatment schedule according to the brachytherapy used to complement the dose of external beam radiotherapy (EBRT): 1 - High dose rate (HDR) - 36 patients - 4 weekly insertions of 6,0 Gy at point A 2 - Low dose rate (LDR) - 29 patients - 2 insertions two weeks apart of 17,5 Gy at point A The External Beam radiotherapy was performed through a Linac 4MV, in box arrangement for whole pelvis and in AP-PA fields for parametrial complementation of dose. The dose at the whole pelvis was 45 Gy in 25 fractions of 1,8 Gy and the parametrial dose was 16 Gy. The brachytherapy was realized with Fletcher colpostats and intrauterine tandem, in both arms. The HDR brachytherapy was realized through a Micro-Selectron device, working with Iridium-192 with initial activity of 10 Ci and started ten days after the beginning of EBRT. The total treatment time was shortened in two weeks for this group. The LDR brachytherapy started only after the end of EBRT. Results: With the minimum follow up of 24 months and medium of 31 months, the disease free survival was 50% among the 36 patients in HDR group and 47,8% among the 29 patients in LDR group. Local failures occurred in 50% and 52,8% respectively. Grade I and II complications were restricted to rectites and cistites and the incidence of them was 8,3% for HDR group and 13% for LDR group. Until the time of evaluation there were no grade III complications in any group. Conclusions: Although the number of patients is small and the time of follow up still short, these preliminary results suggest that the HDR brachytherapy has an equivalent efficiency in local control as the LDR in the treatment of stage IIIB

  8. Clinical and neuroimaging correlates of antiphospholipid antibodies in multiple sclerosis: a preliminary study

    Directory of Open Access Journals (Sweden)

    Gonzalez-Toledo Eduardo

    2007-10-01

    Full Text Available Abstract Background The presence of antiphospholipid antibodies (APLA in multiple sclerosis (MS patients has been reported frequently but no clear relationship between APLA and the clinical and neuroimaging features of MS have heretofore been shown. We assessed the clinical and neuroimaging features of MS patients with plasma APLA. Methods A consecutive cohort of 24 subjects with relapsing-remitting (RR MS were studied of whom 7 were in remission (Rem and 17 in exacerbation (Exc. All subjects were examined and underwent MRI of brain. Patients' plasma was tested by standard ELISA for the presence of both IgM and IgG antibodies using a panel of 6 targets: cardiolipin (CL, β2 glycoprotein I (β2GPI, Factor VII/VIIa (FVIIa, phosphatidylcholine (PC, phosphatidylserine (PS and phosphatidylethanolamine (PE. Results In exacerbation up to 80% of MS subjects had elevated titers of IgM antibodies directed against the above antigens. However, in remission, less than half of MS patients had elevated titers of IgM antibodies against one or more of the above antigens. This difference was significant, p Conclusion The findings of this preliminary study show that increased APLA IgM is associated with exacerbations of MS. Currently, the significance of this association in pathogenesis of MS remains unknown. However, systematic longitudinal studies to measure APLA in larger cohorts of patients with relapsing-remitting MS, particularly before and after treatment with immunomodulatory agents, are needed to confirm these preliminary findings.

  9. Multicenter study on evaluation of the entrance skin dose by a direct measurement method in cardiac interventional procedures

    International Nuclear Information System (INIS)

    Kato, Mamoru; Chida, Koichi; Moritake, Takashi

    2016-01-01

    Deterministic effects have been reported in cardiac interventional procedures. To prevent radiation skin injuries in percutaneous coronary intervention (PCI), it is necessary to measure accurate patient entrance skin dose (ESD) and maximum skin absorbed dose (MSD). We measured the MSD on 62 patients in four facilities by using the Chest-RADIREC system. The correlation between MSD and fluoroscopic time, dose area product (DAP), and cumulative air kerma (AK) showed good results, with the correlation between MSD and AK being the strongest. The regression lines using MSD as an outcome value (y) and AK as predictor variables (x) was y=1.18x (R 2 =0.787). From the linear regression equation, MSD is estimated to be about 1.18 times that of AK in real time. The Japan diagnostic reference levels (DRLs) 2015 for IVR was established by the use of dose rates using acrylic plates (20 cm thick) at the interventional reference point. Preliminary reference levels proposed by International Atomic Energy Agency (IAEA) were provided using DAP. In this study, AK showed good correlation most of all. Hence we think that Japanese DRLs for IVR should reconsider by clinical patients' exposure dose such as AK. (author)

  10. Neglectable benefit of searching for incidental findings in the Dutch-Belgian lung cancer screening trial (NELSON) using low-dose multidetector CT

    International Nuclear Information System (INIS)

    Wiel, J.C.M. van de; Wang, Y.; Xu, D.M.; Zaag-Loonen, H.J. van der; Jagt, E.J. van der; Oudkerk, M.; Klaveren, R.J. van

    2007-01-01

    The purpose of this study was to prospectively determine the frequency and spectrum of incidental findings (IFs) and their clinical implications in a high risk population for lung cancer undergoing low-dose multidetector computed tomography (MDCT) screening for lung cancer. Scans of 1,929 participants were evaluated for lung lesions and IFs by two radiologists. IFs were categorised as not clinically relevant or possibly clinically relevant. Findings were considered possibly clinically relevant if they could require further evaluation or could have substantial clinical implications. All possibly clinically relevant IFs were reviewed by a third radiologist, who determined its clinical relevance. Of all 1,929 participants, 1,410 (73%) had not clinically relevant IFs and 163 (8%) had possibly clinically relevant IFs of which 129 (79%) were indeed considered clinically relevant. Additional imaging was performed mainly by ultrasound (112 of 118, 96%). All but one lesion were concluded to be benign, mostly cysts (n = 115, 80%). Only 21 (1%) participants had findings with clinical implications. In one participant a malignancy was found, yet without any clinical benefit since no curative treatment was possible. Based on our results, we advise against systematically searching for and reporting of IFs in lung cancer screening studies using low-dose MDCT. (orig.)

  11. Finding Silver Linings: A Preliminary Examination of Benefit Finding in Youth With Chronic Pain.

    Science.gov (United States)

    Soltani, Sabine; Neville, Alex; Hurtubise, Karen; Hildenbrand, Aimee; Noel, Melanie

    2018-04-01

    Chronic pain is a pervasive condition in adolescence and is associated with significant psychological distress, functional disability, social isolation, and decreased quality of life for a subset of affected youth. There is a paucity of research examining potential resilience factors and adaptive processes in pediatric chronic pain. Benefit finding refers to the process of perceiving positive consequences in the face of adversity. Previous research on benefit finding in pediatric samples (e.g., oncology; acute injury) has yielded inconsistent results. This is the first study to examine this construct in youth with chronic pain. The objective of the current investigation was to extend previous research on benefit finding to adolescents with chronic pain and to assess relationships between benefit finding, internalizing mental health symptoms (i.e., anxiety, depression, and posttraumatic stress disorder [PTSD]), pain outcomes (pain intensity and interference), and quality of life. Psychometrically sound self-report measures of benefit finding, anxiety, depressive, and PTSD symptoms, pain intensity, pain interference, and quality of life were completed by 145 youth (67.4% female, Mage = 13.3 years, SD = 2.6), referred to a tertiary-level chronic pain program. Benefit finding was significantly correlated with internalizing mental health symptoms, pain outcomes, and quality of life. Further, benefit finding significantly predicted children's self-reported pain intensity, pain interference, and quality of life when controlling for age and sex. Findings suggest that benefit finding is associated with internalizing mental health symptoms, pain outcomes, and quality of life in youth with chronic pain. Future research examining this construct is warranted.

  12. Patient doses in interventional cardiology procedures

    International Nuclear Information System (INIS)

    Domienik, J.; Papierz, S.; Jankowski, J.; Peruga, J.Z.

    2008-01-01

    In most countries of European Union legislation requires the determination of the total skin dose to patient resulting from interventional procedures to assess the risk of deterministic effect. To this end, various dose indicators like dose area product (DAP), cumulative dose (CD) and entrance dose at the patient plane (EFD) are used in clinical practice. The study aims at relating those dose indicators with doses ascribe to the most irradiated areas of the patient skin usually expressed in terms of local maximal skin dose (MSD). For the study the local MSD and related to their areas are investigated and compared for coronary angiography CA and intervention (PCI). Two methods implying radiographic films Kodak EDR2 and matrixes of thermoluminescent dosimeters (TLDs) are applied for direct measurements of dose distribution for selected procedures. Both methods are compared. Additionally, for patient dosimetry the following data: MSD, CD, EFD, fluoroscopy time (FT), number of acquired images, total DAP, fluoro-DAP and record-DAP were collected for randomly selected procedure. The statistical quantities like: median, 3 rd quartile, mean and standard deviation for all dosimetric parameters are determined. Preliminary study showed that the values of data collected for coronary procedures are in the ranges 0,7 - 27,3 min for fluoroscopy time, 50 - 350 Gy cm 2 for total DAP, 300 - 2000 mGy for CD, 140 - 2000 mGy for EFD and 100 - 1500 mGy for local maximal skin dose. For interventions the ranges are, accordingly 3,0 - 43,6 min , 25 - 450 Gy cm 2 , 270 - 6600 mGy, 80 - 2600 mGy and 80 - 1500 mGy. As a result of the study the correlations between dose indicators and local MSD are analyzed. The concentration of dose on irradiated films are going to be investigated in some detail as well. (author)

  13. A Preliminary Study for Evaluating the Dose-Dependent Effect of d-Allulose for Fat Mass Reduction in Adult Humans: A Randomized, Double-Blind, Placebo-Controlled Trial

    Directory of Open Access Journals (Sweden)

    Youngji Han

    2018-01-01

    Full Text Available d-allulose is a rare sugar with zero energy that can be consumed by obese/overweight individuals. Many studies have suggested that zero-calorie d-allulose has beneficial effects on obesity-related metabolism in mouse models, but only a few studies have been performed on human subjects. Therefore, we performed a preliminary study with 121 Korean subjects (aged 20–40 years, body mass index ≥ 23 kg/m2. A randomized controlled trial involving placebo control (sucralose, 0.012 g × 2 times/day, low d-allulose (d-allulose, 4 g × 2 times/day, and high d-allulose (d-allulose, 7 g × 2 times/day groups was designed. Parameters for body composition, nutrient intake, computed tomography (CT scan, and plasma lipid profiles were assessed. Body fat percentage and body fat mass were significantly decreased following d-allulose supplementation. The high d-allulose group revealed a significant decrease in not only body mass index (BMI, but also total abdominal and subcutaneous fat areas measured by CT scans compared to the placebo group. There were no significant differences in nutrient intake, plasma lipid profiles, markers of liver and kidney function, and major inflammation markers among groups. These results provide useful information on the dose-dependent effect of d-allulose for overweight/obese adult humans. Based on these results, the efficacy of d-allulose for body fat reduction needs to be validated using dual energy X-ray absorption.

  14. A Preliminary Study for Evaluating the Dose-Dependent Effect of d-Allulose for Fat Mass Reduction in Adult Humans: A Randomized, Double-Blind, Placebo-Controlled Trial.

    Science.gov (United States)

    Han, Youngji; Kwon, Eun-Young; Yu, Mi Kyeong; Lee, Seon Jeong; Kim, Hye-Jin; Kim, Seong-Bo; Kim, Yang Hee; Choi, Myung-Sook

    2018-01-31

    d-allulose is a rare sugar with zero energy that can be consumed by obese/overweight individuals. Many studies have suggested that zero-calorie d-allulose has beneficial effects on obesity-related metabolism in mouse models, but only a few studies have been performed on human subjects. Therefore, we performed a preliminary study with 121 Korean subjects (aged 20-40 years, body mass index ≥ 23 kg/m²). A randomized controlled trial involving placebo control (sucralose, 0.012 g × 2 times/day), low d-allulose (d-allulose, 4 g × 2 times/day), and high d-allulose (d-allulose, 7 g × 2 times/day) groups was designed. Parameters for body composition, nutrient intake, computed tomography (CT) scan, and plasma lipid profiles were assessed. Body fat percentage and body fat mass were significantly decreased following d-allulose supplementation. The high d-allulose group revealed a significant decrease in not only body mass index (BMI), but also total abdominal and subcutaneous fat areas measured by CT scans compared to the placebo group. There were no significant differences in nutrient intake, plasma lipid profiles, markers of liver and kidney function, and major inflammation markers among groups. These results provide useful information on the dose-dependent effect of d-allulose for overweight/obese adult humans. Based on these results, the efficacy of d-allulose for body fat reduction needs to be validated using dual energy X-ray absorption.

  15. Preliminary findings of altered functional connectivity of the default mode network linked to functional outcomes one year after pediatric traumatic brain injury.

    Science.gov (United States)

    Stephens, Jaclyn A; Salorio, Cynthia F; Barber, Anita D; Risen, Sarah R; Mostofsky, Stewart H; Suskauer, Stacy J

    2017-07-10

    This study examined functional connectivity of the default mode network (DMN) and examined brain-behavior relationships in a pilot cohort of children with chronic mild to moderate traumatic brain injury (TBI). Compared to uninjured peers, children with TBI demonstrated less anti-correlated functional connectivity between DMN and right Brodmann Area 40 (BA 40). In children with TBI, more anomalous less anti-correlated) connectivity between DMN and right BA 40 was linked to poorer performance on response inhibition tasks. Collectively, these preliminary findings suggest that functional connectivity between DMN and BA 40 may relate to longterm functional outcomes in chronic pediatric TBI.

  16. A Preliminary Study of D-Cycloserine Augmentation of Cognitive-Behavioral Therapy in Pediatric Obsessive-Compulsive Disorder

    Science.gov (United States)

    Storch, Eric A.; Murphy, Tanya K.; Goodman, Wayne K.; Geffken, Gary R.; Lewin, Adam B.; Henin, Aude; Micco, Jamie A.; Sprich, Susan; Wilhelm, Sabine; Bengtson, Michael; Geller, Daniel A.

    2010-01-01

    Background Research on the neural circuitry underlying fear extinction has led to the examination of d-cycloserine (DCS), a partial agonist at the NMDA receptor in the amygdala, as a method of enhancing exposure therapy outcome. Preliminary results have supported the use of DCS to augment exposure therapy in adult anxiety disorders; however, no data have been reported in any childhood anxiety disorder. Thus, we sought to preliminarily examine if weight-adjusted DCS doses (25 or 50mg) enhanced the overall efficacy of cognitive-behavioral therapy (CBT) for pediatric obsessive-compulsive disorder (OCD). Method Participants were 30 youth (ages 8–17) with a primary diagnosis of OCD. The study design was a randomized, double-blinded, placebo-controlled augmentation trial examining CBT+DCS versus CBT+Placebo (15 youth per group). All patients received 7 E/RP sessions paired with DCS or placebo taken 1 hour prior to sessions. Results Although not significantly different, compared to the CBT+Placebo group, youth in the CBT+DCS arm showed small-to-moderate treatment effects (d=.31 to .47 on primary outcomes). No adverse events were recorded. Conclusions The present results complement findings in adult OCD and non-OCD anxiety disorders and provide initial support for a more extensive study of DCS augmentation of CBT among youth with OCD. PMID:20817153

  17. Influence of study satisfaction on academic procrastination in psychology students: a preliminary study

    Directory of Open Access Journals (Sweden)

    Sergio Alexis Dominguez-Lara

    2017-06-01

    Full Text Available The aim of this predictive study was to analyze the degree of influence of study satisfaction (SS on academic procrastination (AP. One hundred forty- eight (148 psychology students (111 women between 18 and 32 years old (M = 22.41 were evaluated using the Brief Scale of Study Satisfaction and the Academic Procrastination Scale. After preliminary analyses focused on the scores reliability (α > 0.70 and correlations between dimensions, a regression analysis was performed to determine how much of the variability in the AP dimensions’ scores is explained by the variations in the SS. For that purpose, a method that uses bivariate correlations corrected for attenuation and provides confidence intervals under a bootstrap approach of the associated statistics was applied. All analyses were assessed from an effect size approach. The results indicate that the influence of SS on AP was not significant. These findings provide new ways to implement studies in order to understand the procrastinating behavior in the university setting.

  18. Dosimetry studies with 32P source and correlation of skin and eye lens doses

    International Nuclear Information System (INIS)

    Kumar, Munish; Gaonkar, U.P.; Koul, D.K.; Datta, D.; Saxena, S.K.; Kumar, Yogendra; Dash, A.

    2018-01-01

    Beta particles are one of the major contributors toward skin and eye lens doses at facilities handling beta sources. These sources find applications in industry, pharmaceuticals as well as in brachytherapy applications. The beta particles having maximum (E max ) energy > 0.07 MeV are capable of delivering skin dose whereas beta particles having maximum (E max ) energy > 0.7 MeV may also contribute towards dose to eye lens. Studies are performed using 32 P beta source as its maximum beta energy (E max ) is such that for sources having (E max ) of 1.71 MeV or beyond, there can be substantial contribution towards dose to eye lens even the dose limit recommended for skin is followed

  19. Estimation of collective effective dose equivalent from environmental radiation and radioactive materials in Japan. A preliminary study

    International Nuclear Information System (INIS)

    Maruyama, Takashi; Noda, Yutaka; Takeshita, Mitsue; Iwai, Kazuo.

    1994-01-01

    The peaceful uses of nuclear power and radiations have been developed into a stage of practical applications for human life. Radiation causes harmful effects to human beings, although human beings receives a number of invaluable benefits from the nuclear energy and the uses of radiation. In order to examine the optimization of radiation protection in these practices, collective effective dose equivalent from environmental exposures due to natural and artificial radiations have been preliminarily evaluated using most recent data. The resultant collective doses were compared with those from medical and occupational exposures. It is noted that, in Japan, the collective effective dose from environmental radiation sources can be approximately same to that from medical exposure. (author)

  20. A Brief Report: Lessons Learned and Preliminary Findings of Progreso en Salud, an HIV Risk Reduction Intervention for Latina Seasonal Farmworkers

    Directory of Open Access Journals (Sweden)

    Mariano Kanamori

    2016-12-01

    Full Text Available Throughout the past decade, HIV rates in Florida—particularly South Florida, where many Latina seasonal farmworkers reside and work—have ranked among the highest in the nation. In this brief report, we delineate important lessons learned and preliminary findings from the implementation of the HIV prevention intervention Progreso en Salud (Progress in Health. Among the 114 Latina seasonal farmworker participants, there were significant increases from baseline to 6-month follow-up in the percentages of overall condom use, HIV testing, HIV/AIDS-related communications with friends, HIV knowledge, condom use self-efficacy, and correct use of condoms. Lessons learned from this study can be used to inform future HIV intervention strategies to improve the adoption and maintenance of HIV risk reduction behaviors among high-risk Latina seasonal workers and other high-risk underserved populations. Future research is needed to support our findings.

  1. Short time effects of lithium low dose associated to 131I in the treatment of Graves' disease: preliminary study

    International Nuclear Information System (INIS)

    Rey, M.; Gauna, A.; Silva Croome, M.; Guillen, C.; Sartorio, G.

    2004-01-01

    The therapeutic dose of 131 I can increase the tirotoxicose. Although, the advice is the administration of the iodine in euthyroidism, this not always is possible. The lithium, in doses between 900 and 1200 mg/day is useful to help to the treatment with 131 I. These doses are proximity of atomic absorption spectrophotometrics, of the toxicity limits. Recently we have brought the utility of low doses of lithium in the treatment of the hyperthyroidism

  2. Towards tracer dose reduction in PET studies: Simulation of dose reduction by retrospective randomized undersampling of list-mode data.

    Science.gov (United States)

    Gatidis, Sergios; Würslin, Christian; Seith, Ferdinand; Schäfer, Jürgen F; la Fougère, Christian; Nikolaou, Konstantin; Schwenzer, Nina F; Schmidt, Holger

    2016-01-01

    Optimization of tracer dose regimes in positron emission tomography (PET) imaging is a trade-off between diagnostic image quality and radiation exposure. The challenge lies in defining minimal tracer doses that still result in sufficient diagnostic image quality. In order to find such minimal doses, it would be useful to simulate tracer dose reduction as this would enable to study the effects of tracer dose reduction on image quality in single patients without repeated injections of different amounts of tracer. The aim of our study was to introduce and validate a method for simulation of low-dose PET images enabling direct comparison of different tracer doses in single patients and under constant influencing factors. (18)F-fluoride PET data were acquired on a combined PET/magnetic resonance imaging (MRI) scanner. PET data were stored together with the temporal information of the occurrence of single events (list-mode format). A predefined proportion of PET events were then randomly deleted resulting in undersampled PET data. These data sets were subsequently reconstructed resulting in simulated low-dose PET images (retrospective undersampling of list-mode data). This approach was validated in phantom experiments by visual inspection and by comparison of PET quality metrics contrast recovery coefficient (CRC), background-variability (BV) and signal-to-noise ratio (SNR) of measured and simulated PET images for different activity concentrations. In addition, reduced-dose PET images of a clinical (18)F-FDG PET dataset were simulated using the proposed approach. (18)F-PET image quality degraded with decreasing activity concentrations with comparable visual image characteristics in measured and in corresponding simulated PET images. This result was confirmed by quantification of image quality metrics. CRC, SNR and BV showed concordant behavior with decreasing activity concentrations for measured and for corresponding simulated PET images. Simulation of dose

  3. Predicting methylphenidate response in attention deficit hyperactivity disorder: a preliminary study.

    Science.gov (United States)

    Johnston, Blair A; Coghill, David; Matthews, Keith; Steele, J Douglas

    2015-01-01

    Methylphenidate (MPH) is established as the main pharmacological treatment for patients with attention deficit hyperactivity disorder (ADHD). Whilst MPH is generally a highly effective treatment, not all patients respond, and some experience adverse reactions. Currently, there is no reliable method to predict how patients will respond, other than by exposure to a trial of medication. In this preliminary study, we sought to investigate whether an accurate predictor of clinical response to methylphenidate could be developed for individual patients, using sociodemographic, clinical and neuropsychological measures. Of the 43 boys with ADHD included in this proof-of-concept study, 30 were classed as responders and 13 as non-responders to MPH, with no significant differences in age nor verbal intelligence quotient (IQ) between the groups. Here we report the application of a multivariate analysis approach to the prediction of clinical response to MPH, which achieved an accuracy of 77% (p = 0.005). The most important variables to the classifier were performance on a 'go/no go' task and comorbid conduct disorder. This preliminary study suggested that further investigation is merited. Achieving a highly significant accuracy of 77% for the prediction of MPH response is an encouraging step towards finding a reliable and clinically useful method that could minimise the number of children needlessly being exposed to MPH. © The Author(s) 2014.

  4. A study on the annual equivalent doses received by cardiologists in a UK hospital

    International Nuclear Information System (INIS)

    Fong, R.Y.L.; Ryan, E.; Alonso-Arrizabalaga, S.

    2001-01-01

    A dose assessment study was carried out to determine the likely annual equivalent doses received by various parts of a cardiologist's body. High sensitivity GR-200 thermoluminescent dosemeters were attached to cardiologists' foreheads, little fingers, wrists, elbows, knees and ankles. Three common cardiology procedures were investigated, namely, percutaneous transluminal coronary angioplasty (PTCA), permanent pacemaker insertion (PPM) and left heart catheterisation (LHC). Dose monitoring was done on a case-by-case basis. Data on ten cases of each procedure were gathered. The projected annual equivalent doses were computed by averaging the ten doses measured at each site for each examination type and finding out from the cardiologists how many cases of PTCA, PPM and LHC they do in a year. Results in this study show that for the lens of the eye, the projected annual equivalent dose is below 10 mSv and for the other body parts, it is below 100 mSv per year. The study demonstrated that the methodology used can help to optimise radiation protection in diagnostic radiology. (author)

  5. A thermoluminescence study of mineral silicates extracted from herbs in the dose range 0.5–5 Gy

    International Nuclear Information System (INIS)

    Della Monaca, Sara; Fattibene, Paola; Bortolin, Emanuela

    2013-01-01

    The presence of silicates in many personal objects suggests their potential use at low dose as fortuitous dosimeter in an accidental radiological exposure, when conventional dosimetry is not available. The goal of the present work is the dosimetric characterization of mineral silicates extracted from the plant Hibiscus Sabdariffa L, known as Jamaica flower, in the dose range 0.5–5 Gy. By studying the radiation-induced signal in time, the temperature integration region between 210 °C and 250 °C was found to be the most stable and also reduced the effects of thermal fading in the dose reconstruction process; the dose response curve was linear between 0.5 Gy and 5 Gy. By checking the change in sensitivity after repeated exposures to ionizing radiations and to high temperature heating, no variation in the glow curve shape or peak intensities were detected. To eliminate a pre-existing background signal, all the characterization measurements were performed with aliquots “annealed” by a preliminary readout of the TL. - Highlights: • Glow curves change in shape and intensity just in the first 3 days after irradiation. • The dose response is linear in the dose range 0.5–5 Gy. • The curve shape or intensity don't change after repeated exposures and heatings. • Encouraging results were obtained in the dose recovery test

  6. Safety, tolerability, and preliminary activity of CUDC-907, a first-in-class, oral, dual inhibitor of HDAC and PI3K, in patients with relapsed or refractory lymphoma or multiple myeloma: an open-label, dose-escalation, phase 1 trial.

    Science.gov (United States)

    Younes, Anas; Berdeja, Jesus G; Patel, Manish R; Flinn, Ian; Gerecitano, John F; Neelapu, Sattva S; Kelly, Kevin R; Copeland, Amanda R; Akins, Amy; Clancy, Myles S; Gong, Lucy; Wang, Jing; Ma, Anna; Viner, Jaye L; Oki, Yasuhiro

    2016-05-01

    (84%) patients had discontinued study drug as a result of progressive disease or clinical signs of progressive disease at the data cutoff. Four DLTs occurred in three of 40 DLT-evaluable patients (diarrhoea and hyperglycaemia in one patient on 60 mg once daily, hyperglycaemia in one patient on 150 mg twice weekly, and diarrhoea in one patient on 150 mg three times weekly); no DLTs were reported in patients on the 5/2 schedule. Grade 3 or worse adverse events occurred in 19 (43%) of 44 patients, the most common of which were thrombocytopenia (in nine [20%] of 44 patients), neutropenia (three [7%]), and hyperglycaemia (three [7%]). 11 (25%) of 44 patients had serious adverse events, three of which were regarded as treatment related (epistaxis and the DLTs of diarrhoea and hyperglycaemia). Adverse events led to dose reductions in six (14%) patients and treatment discontinuation in seven (16%). Five (14%) of 37 response-evaluable patients achieved an objective response (two complete responses and three partial responses). All five responses occurred in the subgroup of patients with diffuse large B-cell lymphoma (DLBCL; n=9), and three occurred in those with transformed follicular lymphoma DLBCL (n=5). 21 (57%) of 37 response-evaluable patients had stable disease, including those with DLBCL, Hodgkin's lymphoma, and multiple myeloma. On the basis of these findings, we selected CUDC-907 60 mg on the 5/2 dosing schedule as the recommended phase 2 dose. The safety and tolerability profile of CUDC-907 and the promising preliminary evidence of response support continued development of CUDC-907 at the 60 mg 5/2 dosing schedule, alone and in combination with other therapies. A dose-expansion trial of this dose in patients with refractory and relapsed DLBCL in particular, is ongoing. Curis, Inc, and the Leukemia and Lymphoma Society. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Bottlenecks in the development of topical analgesics: molecule, formulation, dose-finding, and phase III design

    Directory of Open Access Journals (Sweden)

    Keppel Hesselink JM

    2017-03-01

    Full Text Available Jan M Keppel Hesselink,1 David J Kopsky,2 Stephen M Stahl3 1Institute Neuropathic Pain, Bosch en Duin, the Netherlands; 2Institute Neuropathic Pain, Amsterdam, the Netherlands; 3University of California San Diego, La Jolla, CA, USA Abstract: Topical analgesics can be defined as topical formulations containing analgesics or co-analgesics. Since 2000, interest in such formulations has been on the rise. There are, however, four critical issues in the research and development phases of topical analgesics: 1 The selection of the active pharmaceutical ingredient. Analgesics and co-analgesics differ greatly in their mechanism of action, and it is required to find the most optimal fit between such mechanisms of action and the pathogenesis of the targeted (neuropathic pain. 2 Issues concerning the optimized formulation. For relevant clinical efficacy, specific characteristics for the selected vehicle (eg, cream base or gel base are required, depending on the physicochemical characteristics of the active pharmaceutical ingredient(s to be delivered. 3 Well-designed phase II dose-finding studies are required, and, unfortunately, such trials are missing. In fact, we will demonstrate that underdosing is one of the major hurdles to detect meaningful and statistically relevant clinical effects of topical analgesics. 4 Selection of clinical end points and innovatively designed phase III trials. End point selection can make or break a trial. For instance, to include numbness together with tingling as a composite end point for neuropathic pain seems stretching the therapeutic impact of an analgesic too far. Given the fast onset of action of topical analgesics (usually within 30 minutes, enrichment designs might enhance the chances for success, as the placebo response might decrease. Topical analgesics may become promising inroads for the treatment of neuropathic pain, once sufficient attention is given to these four key aspects. Keywords: topical, analgesics

  8. Traffics and wildlife: A preliminary study on road-kill

    OpenAIRE

    Rustiati, Elly Lestari

    2012-01-01

    This paper presents the preliminary finding on road kill survey by direct observations onthe high ways. The road-kills recorded of small wildlife, including medium size-mammal (2.50%, n =1), birds (5.00%, n = 2) and small mammals (92.50%, n = 37). The small mammals include the mostcommon mammals in the areas, squirrels, raccoons, skunks and woodchuck. Of mammals, squirrels(35.00%) were the highest recorded, followed by woodchucks (25.00%), mice/shrew (17.50%),raccoons (10.00%), skunk (5.00%) ...

  9. Method to stimulate dose gradient in liquid media

    International Nuclear Information System (INIS)

    Scarlat, F.

    1993-01-01

    The depth absorbed dose from electrons with energy higher than 10 MeV shows a distribution with a big-percentage absorbed dose at the entrance surface and a small dose gradient. This is due to the big distance between the virtual focus and irradiated liquid medium. In order to stimulate dose gradient and decrease the surface dose, this paper presents a method for obtaining the second focus by means of a magnetostatic planar wiggler. Preliminary calculations indicated that the absorbed dose rate increases two-three times at the reference plane in the irradiated liquid medium. (Author)

  10. Preliminary assessment of radiological doses in alternative waste management systems without an MRS facility

    International Nuclear Information System (INIS)

    Schneider, K.J.; Pelto, P.J.; Daling, P.M.; Lavender, J.C.; Fecht, B.A.

    1986-06-01

    This report presents generic analyses of radiological dose impacts of nine hypothetical changes in the operation of a waste management system without a monitored retrievable storage (MRS) facility. The waste management activities examined in this study include those for handling commercial spent fuel at nuclear power reactors and at the surface facilities of a deep geologic repository, and the transportation of spent fuel by rail and truck between the reactors and the repository. In the reference study system, the radiological doses to the public and to the occupational workers are low, about 170 person-rem/1000 metric ton of uranium (MTU) handled with 70% of the fuel transported by rail and 30% by truck. The radiological doses to the public are almost entirely from transportation, whereas the doses to the occupational workers are highest at the reactors and the repository. Operating alternatives examined included using larger transportation casks, marshaling rail cars into multicar dedicated trains, consolidating spent fuel at the reactors, and wet or dry transfer options of spent fuel from dry storage casks. The largest contribution to radiological doses per unit of spent fuel for both the public and occupational workers would result from use of truck transportation casks, which are smaller than rail casks. Thus, reducing the number of shipments by increasing cask sizes and capacities (which also would reduce the number of casks to be handled at the terminals) would reduce the radiological doses in all cases. Consolidating spent fuel at the reactors would reduce the radiological doses to the public but would increase the doses to the occupational workers at the reactors

  11. Gender Differences in Radiation Dose from Nuclear Cardiology Studies Across the World: Findings from the International Atomic Energy Agency Nuclear Cardiology Protocols Study (INCAPS) Registry

    Science.gov (United States)

    Shi, Lynn; Dorbala, Sharmila; Paez, Diana; Shaw, Leslee J.; Zukotynski, Katherine A.; Pascual, Thomas N. B.; Karthikeyan, Ganesan; Vitola, João V.; Better, Nathan; Bokhari, Nadia; Rehani, Madan M.; Kashyap, Ravi; Dondi, Maurizio; Mercuri, Mathew; Einstein, Andrew J.

    2016-01-01

    OBJECTIVES The aim of this study was to investigate gender-based differences in nuclear cardiology practice, globally, with particular focus on laboratory volume, radiation dose, protocols, and best practices. BACKGROUND It is unclear if gender-based differences exist in radiation exposure for nuclear cardiology procedures. METHODS In a large multicenter observational cross-sectional study encompassing 7911 patients in 65 countries, radiation effective dose was estimated for each examination. Patient-level best practices relating to radiation exposure were compared between genders. Analysis of covariance was utilized to determine any difference in radiation exposure according to gender, region, and the interaction between gender and region. Linear, logistic, and hierarchical regression models were developed to evaluate gender-based differences in radiation exposure and laboratory adherence to best practices. We also included the United Nations’ gender inequality and human development indices as covariates in multivariable models. RESULTS The proportion of MPI studies performed in women varied between countries, however there was no significant correlation with gender inequality index. Globally, mean effective dose for nuclear cardiology procedures was only slightly lower in women (9.6±4.5 mSv) than in men (10.3±4.5 mSv men, pnuclear cardiology procedures, only small differences were observed between genders worldwide. Regional variations noted in MPI use and radiation dose offer potential opportunities to address gender-related differences in delivery of nuclear cardiology care. PMID:27056156

  12. Bupivacaine in microcapsules prolongs analgesia after subcutaneous infiltration in humans: a dose-finding study

    DEFF Research Database (Denmark)

    Pedersen, Juri L; Lillesø, Jesper; Hammer, Niels A

    2004-01-01

    In this study, we examined the onset and duration of local analgesic effects of bupivacaine incorporated into biodegradable microcapsules (extended-duration local anesthetic; EDLA) administered as subcutaneous infiltrations in different doses in humans. In 18 volunteers, the skin on the medial calf...... was infiltrated with 10 mL of EDLA, and the opposite calf was infiltrated with 10 mL of aqueous bupivacaine (5.0 mg/mL) in a double-blinded, randomized manner. Three different concentrations of EDLA were tested (6.25, 12.5, and 25 mg/mL), with 6 subjects in each group. Pain responses to mechanical and heat......, and 6 mo after the injections. The time to maximum effects was significantly shorter for aqueous bupivacaine (2-6 h) than for EDLA (4-24 h), but there were no significant differences between the maximum effects of EDLA and aqueous bupivacaine. From 24 to 96 h after the injections, EDLA was significantly...

  13. Preliminary safety assessment of the WIPP facility

    International Nuclear Information System (INIS)

    Balestri, R.J.; Torres, B.W.; Pahwa, S.B.; Brannen, J.P.

    1979-01-01

    This paper summarizes the efforts to perform a safety assessment of the Waste Isolation Pilot Plant (WIPP) facility being proposed for southeastern New Mexico. This preliminary safety assessment is limited to a consequence assessment in terms of the dose to a maximally exposed individual as a result of introducing the radionuclides into the biosphere. The extremely low doses to the organs as a result of the liquid breach scenarios are contrasted with the background radiation

  14. Late effects of various dose-fractionation regimens

    International Nuclear Information System (INIS)

    Turesson, I.; Notter, G.

    1983-01-01

    These clinical investigations of various dose-fractionation regimens on human skin show that: The late reactions cannot be predicted from the early reactions; The dose-response curves for late reactions are much steeper than for early reactions; Equivalent doses for various fractionation schedules concerning late effects can be calculated by means of a corrected CRE (NSD) formula; the correction must be considered preliminary because further follow-up is needed. A clinical fractionation study of this type requires: Extremely careful dosimetry; Study of the same anatomical region; Very long follow-up; Studies at different effect levels; Skin reaction is the only end point we have studied systematically for different fractionation regimens. Experience with the CRE formula as a model for calculating isoeffect doses for different fractionation schedules in routine clinical use can be summarized as follows: The CRE formula has been used prospectively since 1972 in all patients; CRE-equivalent weekly doses to 5 x 2.0 Gy per week has been used. (Although the fractionation schedule is changed, the overall treatment time is still the same); The CRE range was 18 to 21 for curative radiotherapy on carcinomas; No irradiation was applied during pronounced acute reactions. No unexpected complications have been observed under these conditions

  15. Analysis of dose record and epidemiology for radiation workers in Korea

    International Nuclear Information System (INIS)

    Choi, S.Y.; Kim, T.H.

    2003-01-01

    This study presents data on the externally received doses and preliminary results of epidemiological survey for radiation workers. The statistical analysis was carried out in order to understand better the occupational radiation doses in Korea. Records containing dose information from 1984 to 1999 for 64,518 persons were extracted from the National Dose Registry of Korea (Korea Radioisotope Association's personal dose record). The total number of workers registered from 1984 to 1999 was 64,518. The number of workers steadily increased and the accumulated dose somewhat increased. The proportion of radiation workers by occupation was 38.4% for nuclear power plant, 20.3% for industrial organization and 12.4% for non-destructive industry, respectively. The collective annual dose of radiation workers was 31.72 man Sv in 1999. The mean annual dose by sex was 1.49 mSv for male and 0.56 mSv for female. The mean annual dose for workers was 1.41 mSv with the highest mean dose being received by non-destructive industry (3.53 mSv). Very few workers(0.8%) received more than 20 mSv and only one more than 50 mSv, the legal limit for an annual dose. There has been a steady decline in the mean dose since 1984, showing a significant decrease in dose with time. The data showed that radiation protection in Korea was improving, though annual doses were still higher than other countries. Nevertheless, this finding brings to light the necessity of the workers to pay more careful attention to radiation protection procedures and practices, and suggest the need for continuous effort to implement procedures. We are carrying out epidemiological survey in order to evaluate radiation effects on Korean workers based on radiation dose data from the year of 2000. Follow-up is carrying out in order to detect and measure directly the risks of cancer using the Korean Mortality Data, Cancer Registry and individual investigation

  16. Preliminary study of mercury target structure

    Energy Technology Data Exchange (ETDEWEB)

    Kaminaga, Masanori; Haga, Katsuhiro; Hino, Ryutaro [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Kumasaka, Katsuyuki; Uchida, Shoji; Nakagawa, Toshi; Mori, Seiji; Nishikawa, Akira

    1997-11-01

    Development of a proton accelerator based neutron source (1.5 GeV, 5.3 mA (for neutron source 3.3 mA), thermal power 8 MW) is currently conducted by the Special Task Force for Neutron Science Initiative, JAERI. Preliminary design studies and related R and D of a solid metal target for the first stage (1.5 GeV, 1 mA) and a liquid metal target for both the first and second stages (1.5 GeV, 3.3 mA) are conducted by the Target Group to develop both solid and liquid metal target systems. A few kinds of target structures have been investigated in FY 1996 and the preliminary results for the target structures are described in this paper. Investigation results of alternative materials for the target container are also described in this paper. (author)

  17. Dose rate and dose fractionation studies in total body irradiation of dogs

    International Nuclear Information System (INIS)

    Kolb, H.J.; Netzel, B.; Schaffer, E.; Kolb, H.

    1979-01-01

    Total body irradiation (TBI) with 800-900 rads and allogeneic bone marrow transplantation according to the regimen designated by the Seattle group has induced remissions in patients with otherwise refractory acute leukemias. Relapse of leukemia after bone marrow transplantation remains the major problem, when the Seattle set up of two opposing 60 Co-sources and a low dose rate is used in TBI. Studies in dogs with TBI at various dose rates confirmed observations in mice that gastrointestinal toxicity is unlike toxicity against hemopoietic stem cells and possibly also leukemic stem cells depending on the dose rate. However, following very high single doses (2400 R) and marrow infusion acute gastrointestinal toxicity was not prevented by the lowest dose rate studied (0.5 R/min). Fractionated TBI with fractions of 600 R in addition to 1200 R (1000 rads) permitted the application of total doses up to 300 R followed by marrow infusion without irreversible toxicity. 26 dogs given 2400-3000 R have been observed for presently up to 2 years with regard to delayed radiation toxicity. This toxicity was mild in dogs given single doses at a low dose rate or fractionated TBI. Fractionated TBI is presently evaluated with allogeneic transplants in the dog before being applied to leukemic patients

  18. Dose Evaluation of Fractionated Schema and Distance From Tumor to Spinal Cord for Spinal SBRT with Simultaneous Integrated Boost: A Preliminary Study.

    Science.gov (United States)

    Yang, Hao; Cai, Bo-ning; Wang, Xiao-shen; Cong, Xiao-hu; Xu, Wei; Wang, Jin-yuan; Yang, Jun; Xu, Shou-ping; Ju, Zhong-jian; Ma, Lin

    2016-02-23

    BACKGROUND This study investigated and quantified the dosimetric impact of the distance from the tumor to the spinal cord and fractionation schemes for patients who received stereotactic body radiation therapy (SBRT) and hypofractionated simultaneous integrated boost (HF-SIB). MATERIAL AND METHODS Six modified planning target volumes (PTVs) for 5 patients with spinal metastases were created by artificial uniform extension in the region of PTV adjacent spinal cord with a specified minimum tumor to cord distance (0-5 mm). The prescription dose (biologic equivalent dose, BED) was 70 Gy in different fractionation schemes (1, 3, 5, and 10 fractions). For PTV V100, Dmin, D98, D95, and D1, spinal cord dose, conformity index (CI), V30 were measured and compared. RESULTS PTV-to-cord distance influenced PTV V100, Dmin, D98, and D95, and fractionation schemes influenced Dmin and D98, with a significant difference. Distances of ≥2 mm, ≥1 mm, ≥1 mm, and ≥0 mm from PTV to spinal cord meet dose requirements in 1, 3, 5, and 10 fractionations, respectively. Spinal cord dose, CI, and V30 were not impacted by PTV-to-cord distance and fractionation schemes. CONCLUSIONS Target volume coverage, Dmin, D98, and D95 were directly correlated with distance from the spinal cord for spine SBRT and HF-SIB. Based on our study, ≥2 mm, ≥1 mm, ≥1 mm, and ≥0 mm distance from PTV to spinal cord meets dose requirements in 1, 3, 5 and 10 fractionations, respectively.

  19. Ten Years toward Equity: Preliminary Results from a Follow-Up Case Study of Academic Computing Culture

    Directory of Open Access Journals (Sweden)

    Tanya L. Crenshaw

    2017-05-01

    Full Text Available Just over 10 years ago, we conducted a culture study of the Computer Science Department at the flagship University of Illinois at Urbana-Champaign, one of the top five computing departments in the country. The study found that while the department placed an emphasis on research, it did so in a way that, in conjunction with a lack of communication and transparency, devalued teaching and mentoring, and negatively impacted the professional development, education, and sense of belonging of the students. As one part of a multi-phase case study spanning over a decade, this manuscript presents preliminary findings from our latest work at the university. We detail early comparisons between data gathered at the Department of Computer Science at the University of Illinois at Urbana-Champaign in 2005 and our most recent pilot case study, a follow-up research project completed in 2016. Though we have not yet completed the full data collection, we find it worthwhile to reflect on the pilot case study data we have collected thus far. Our data reveals improvements in the perceptions of undergraduate teaching quality and undergraduate peer mentoring networks. However, we also found evidence of continuing feelings of isolation, incidents of bias, policy opacity, and uneven policy implementation that are areas of concern, particularly with respect to historically underrepresented groups. We discuss these preliminary follow-up findings, offer research and methodological reflections, and share next steps for applied research that aims to create positive cultural change in computing.

  20. Comparison of image quality and visibility of normal and abnormal findings at submillisievert chest CT using filtered back projection, iterative model reconstruction (IMR) and iDose{sup 4}™

    Energy Technology Data Exchange (ETDEWEB)

    Laqmani, Azien, E-mail: a.laqmani@uke.de [Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg (Germany); Avanesov, Maxim; Butscheidt, Sebastian; Kurfürst, Maximilian [Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg (Germany); Sehner, Susanne [Department of Medical Biometry and Epidemiology, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg (Germany); Schmidt-Holtz, Jakob; Derlin, Thorsten; Behzadi, Cyrus [Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg (Germany); Nagel, Hans D. [Science & Technology for Radiology, Fritz-Reuter-Weg 5f, 21244 Buchholz, Germany, (Germany); Adam, Gerhard; Regier, Marc [Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg (Germany)

    2016-11-15

    Objective: To compare both image quality and visibility of normal and abnormal findings at submillisievert chest CT (smSv-CT) using filtered back projection (FBP) and the two different iterative reconstruction (IR) techniques iterative model reconstruction (IMR) and iDose{sup 4}™. Materials and methods: This institutional review board approved study was based on retrospective interpretation of clinically indicated acquired data. The requirement to obtain informed consent was waived. 81 patients with suspected pneumonia underwent smSv-CT (Brilliance iCT, Philips Healthcare; mean effective dose: 0.86 ± 0.2 mSv). Data were reconstructed using FBP and two different IR techniques iDose{sup 4}™ and IMR (Philips Healthcare) at various iteration levels. Objective image noise (OIN) was measured. Two experienced readers independently assessed all images for image noise, image appearance and visibility of normal anatomic and abnormal findings. A random intercept model was used for statistical analysis. Results: Compared to FBP and iDose{sup 4}™, IMR reduced OIN up to 88% and 72%, respectively (p < 0.001). A mild blotchy image appearance was seen in IMR images, affecting diagnostic confidence. iDose{sup 4}™ images provided satisfactory to good image quality for visibility of normal and abnormal findings and were superior to FBP (p < 0.001). IMR images were significantly inferior for visibility of normal structures compared to iDose{sup 4}™, while being superior for visibility of abnormal findings except for reticular pattern (p < 0.001). Conclusion: IMR results for visibility of normal and abnormal lung findings are heterogeneous, indicating that IMR may not represent a priority technique for clinical routine. iDose{sup 4}™ represents a suitable method for evaluation of lung tissue at submillisievert chest CT.

  1. Effective radiation dose and eye lens dose in dental cone beam CT: effect of field of view and angle of rotation.

    Science.gov (United States)

    Pauwels, R; Zhang, G; Theodorakou, C; Walker, A; Bosmans, H; Jacobs, R; Bogaerts, R; Horner, K

    2014-10-01

    To quantify the effect of field of view (FOV) and angle of rotation on radiation dose in dental cone beam CT (CBCT) and to define a preliminary volume-dose model. Organ and effective doses were estimated using 148 thermoluminescent dosemeters placed in an anthropomorphic phantom. Dose measurements were undertaken on a 3D Accuitomo 170 dental CBCT unit (J. Morita, Kyoto, Japan) using six FOVs as well as full-rotation (360°) and half-rotation (180°) protocols. For the 360° rotation protocols, effective dose ranged between 54 µSv (4 × 4 cm, upper canine) and 303 µSv (17 × 12 cm, maxillofacial). An empirical relationship between FOV dimension and effective dose was derived. The use of a 180° rotation resulted in an average dose reduction of 45% compared with a 360° rotation. Eye lens doses ranged between 95 and 6861 µGy. Significant dose reduction can be achieved by reducing the FOV size, particularly the FOV height, of CBCT examinations to the actual region of interest. In some cases, a 180° rotation can be preferred, as it has the added value of reducing the scan time. Eye lens doses should be reduced by decreasing the height of the FOV rather than using inferior FOV positioning, as the latter would increase the effective dose considerably. The effect of the FOV and rotation angle on the effective dose in dental CBCT was quantified. The dominant effect of FOV height was demonstrated. A preliminary model has been proposed, which could be used to predict effective dose as a function of FOV size and position.

  2. A dose-finding, cross-over study to evaluate the effect of a Nestorone®/Estradiol transdermal gel delivery on ovulation suppression in normal ovulating women.

    Science.gov (United States)

    Brache, Vivian; Merkatz, Ruth; Kumar, Narender; Jesam, Cristian; Sussman, Heather; Hoskin, Elena; Roberts, Kevin; Alami, Mohcine; Taylor, Deshawn; Jorge, Aidelis; Croxatto, Horacio; Lorange, Ellen; Mishell, Daniel R; Sitruk-Ware, Regine

    2015-10-01

    This study aims to determine the lowest effective of three Nestorone (NES)/estradiol (E2) transdermal gel doses to ensure ovulation suppression in 90-95% of cycles. This was a randomized, open-label, three-treatment-period cross-over study to evaluate the effects of NES/E2 transdermal gel on ovulation inhibition, suppression of follicular growth and pharmacokinetic parameters. The doses were low (1.5 mg NES/0.5 mg E2), medium (3.0 mg NES/1.0 mg E2) and high (4.5 mg NES/1.5 mg E2). Participants applied gel daily to a fixed area on the abdomen for 21 consecutive days. They were interviewed regarding their experiences using the gel. Eighteen participants were randomized; 16 completed the study. Median NES C(max) values for low, medium and high dose groups at day 21 were 318.6 pmol/L, 783.0 pmol/L and 1063.8 pmol/L, respectively. Median maximum follicular diameter was higher with the lowest dose with 16.2 mm versus 10.0 and 10.4 mm with the medium and high doses, respectively. Among adherent participants, ovulation was inhibited in all dose groups, except for one participant in the medium dose (6.7%) that had luteal activity and an ultrasound image suggestive of a luteinized unruptured follicle. There were few reports of unscheduled bleeding, with more episodes reported for the lower dose. Adverse events were mild, and no skin irritation was reported from gel application. While all three doses blocked ovulation effectively and were evaluated as safe and acceptable, the medium dose was considered the lowest effective dose based on a more adequate suppression of follicular development. Further development of this novel contraceptive delivering NES and E2 is warranted and has potential for improved safety compared to ethinyl-estradiol-based methods. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Optimization of vitamin K antagonist drug dose finding by replacement of the international normalized ratio by a bidirectional factor : validation of a new algorithm

    NARCIS (Netherlands)

    Beinema, M J; van der Meer, F J M; Brouwers, J R B J; Rosendaal, F R

    2016-01-01

    UNLABELLED: Essentials We developed a new algorithm to optimize vitamin K antagonist dose finding. Validation was by comparing actual dosing to algorithm predictions. Predicted and actual dosing of well performing centers were highly associated. The method is promising and should be tested in a

  4. Preliminary design study of the TMT Telescope structure system: overview

    Science.gov (United States)

    Usuda, Tomonori; Ezaki, Yutaka; Kawaguchi, Noboru; Nagae, Kazuhiro; Kato, Atsushi; Takaki, Junji; Hirano, Masaki; Hattori, Tomoya; Tabata, Masaki; Horiuchi, Yasushi; Saruta, Yusuke; Sofuku, Satoru; Itoh, Noboru; Oshima, Takeharu; Takanezawa, Takashi; Endo, Makoto; Inatani, Junji; Iye, Masanori; Sadjadpour, Amir; Sirota, Mark; Roberts, Scott; Stepp, Larry

    2014-07-01

    We present an overview of the preliminary design of the Telescope Structure System (STR) of Thirty Meter Telescope (TMT). NAOJ was given responsibility for the TMT STR in early 2012 and engaged Mitsubishi Electric Corporation (MELCO) to take over the preliminary design work. MELCO performed a comprehensive preliminary design study in 2012 and 2013 and the design successfully passed its Preliminary Design Review (PDR) in November 2013 and April 2014. Design optimizations were pursued to better meet the design requirements and improvements were made in the designs of many of the telescope subsystems as follows: 1. 6-legged Top End configuration to support secondary mirror (M2) in order to reduce deformation of the Top End and to keep the same 4% blockage of the full aperture as the previous STR design. 2. "Double Lower Tube" of the elevation (EL) structure to reduce the required stroke of the primary mirror (M1) actuators to compensate the primary mirror cell (M1 Cell) deformation caused during the EL angle change in accordance with the requirements. 3. M1 Segment Handling System (SHS) to be able to make removing and installing 10 Mirror Segment Assemblies per day safely and with ease over M1 area where access of personnel is extremely difficult. This requires semi-automatic sequence operation and a robotic Segment Lifting Fixture (SLF) designed based on the Compliance Control System, developed for controlling industrial robots, with a mechanism to enable precise control within the six degrees of freedom of position control. 4. CO2 snow cleaning system to clean M1 every few weeks that is similar to the mechanical system that has been used at Subaru Telescope. 5. Seismic isolation and restraint systems with respect to safety; the maximum acceleration allowed for M1, M2, tertiary mirror (M3), LGSF, and science instruments in 1,000 year return period earthquakes are defined in the requirements. The Seismic requirements apply to any EL angle, regardless of the

  5. Preliminary studies in rice-fish culture in a rainfed lowland ecology ...

    African Journals Online (AJOL)

    Preliminary studies in rice-fish culture in a rainfed lowland ecology in Ghana. PKA Dartey, RK Bam, J Ofori. Abstract. Mixed farms of rice and fish are yet to receive attention in Ghana, despite lowland rice being grown under inundation in most areas nationwide. In a preliminary study, Nile tilapia (Oreochromis niloticus) was ...

  6. Prospective study on the dose distribution to the acoustic structures during postoperative 3D conformal radiotherapy for parotid tumors. Dosimetric and audiometric aspects

    International Nuclear Information System (INIS)

    Jereczek-Fossa, Barbara A.

    2011-01-01

    To analyze dose distribution in the hearing organ and to evaluate the dose effect on the hearing thresholds in patients treated with post-parotidectomy 3-dimensional conformal radiotherapy (3D-CRT). A total of 17 patients received post-parotidectomy 3D-CRT (median dose: 63 Gy). The audiometric evaluation comprised pure tone audiometry and tympanometry performed before radiotherapy (RT) and 3, 6, and 24 months after RT. The ear structures were delineated on planning computer tomography scans. Mean and maximum doses were calculated and dose-volume histograms were plotted. Before RT, the median baseline audiometric thresholds were normal. At 3 months post-RT, 3 patients were diagnosed as having middle ear underpressure and/or effusion that resolved completely by 6 months. During 2-year follow-up, none of the ears showed perceptive hearing loss at speech frequencies. The mean doses at ipsilateral external auditory canal, mastoids cells, tympanic case, Eustachian tube, semicircular canals, and cochlea were 44.8 Gy, 39.0 Gy, 30.9 Gy, 33.0 Gy, 19.6 Gy, and 19.2 Gy, respectively. The doses to the contralateral ear were negligible, except for the Eustachian tube (up to 28.2 Gy). Post-parotidectomy 3D-CRT is associated with relatively low doses to the ear and the surrounding structures. Post-RT audiometry did not show any permanent (neither conductive nor perceptive) hearing impairment. Only in 3 patients were there signs of transient unilateral dysfunction of the Eustachian tube observed during the first few months after RT. Longer follow-up and larger patient series are warranted to confirm these preliminary findings. (orig.)

  7. Studies on the radioactive contamination due to nuclear detonations II. Preliminary findings on the radioactive fallout due to nuclear detonations

    Energy Technology Data Exchange (ETDEWEB)

    Nishiwaki, Yasushi [Nuclear Reactor Laboratory, Tokyo Institute of Technology, Tokyo (Japan); Nuclear Reactor Laboratoroy, Kinki University, Fuse City, Osaka Precture (Japan)

    1961-11-25

    Since we have detected a considerable amount of artificial radioactivity in the rain in spring 1954, it has become one of the most important items, from the health physics point of view, to continue measurements of radioactivity in the rain and in the atmosphere. To watch out the radioactive contamination of our environment due to repeated nuclear weapons testings in other countries was also considered to be important from the nuclear engineering point of view, in the sense that the permissible allowances of the radioactivity for the peaceful uses of atomic energy might be lowered if the degree of radioactive contamination due to nuclear testings should continue to increase gradually and indefinitely. If the permissible level were lowered, the cost for radiation protection may be expected to increase at the peaceful uses of atomic energy and should the radioactive contamination increase seriously in the future, it was anticipated that we may have to face a very difficult situation in designing the atomic energy facilities for peaceful purposes in our country. From these points of views, we have been continuing measurements of the radioactivity in the rain in Osaka, Japan since the spring of 1954. Some of the preliminary findings are introduced in this paper.

  8. Studies on the radioactive contamination due to nuclear detonations II. Preliminary findings on the radioactive fallout due to nuclear detonations

    International Nuclear Information System (INIS)

    Nishiwaki, Yasushi

    1961-01-01

    Since we have detected a considerable amount of artificial radioactivity in the rain in spring 1954, it has become one of the most important items, from the health physics point of view, to continue measurements of radioactivity in the rain and in the atmosphere. To watch out the radioactive contamination of our environment due to repeated nuclear weapons testings in other countries was also considered to be important from the nuclear engineering point of view, in the sense that the permissible allowances of the radioactivity for the peaceful uses of atomic energy might be lowered if the degree of radioactive contamination due to nuclear testings should continue to increase gradually and indefinitely. If the permissible level were lowered, the cost for radiation protection may be expected to increase at the peaceful uses of atomic energy and should the radioactive contamination increase seriously in the future, it was anticipated that we may have to face a very difficult situation in designing the atomic energy facilities for peaceful purposes in our country. From these points of views, we have been continuing measurements of the radioactivity in the rain in Osaka, Japan since the spring of 1954. Some of the preliminary findings are introduced in this paper

  9. Preliminary studies on factors controlling the rate of regrowth of heavily x-irradiated rat rhabdomyosarcoma tumors

    International Nuclear Information System (INIS)

    Tenforde, T.S.; Curtis, S.B.; Woodruff, H.K.; Parks, D.L.; Daniels, S.J.; Crabtree, K.E.; Schilling, W.A.; DeGuzman, R.J.

    1977-12-01

    Following large single doses of x rays, rat rhabdomyosarcoma tumors exhibit a volume response which characteristically has a swelling phase, a regression phase, a rapid ''initial'' regrowth phase and a slow ''late'' regrowth phase. The preliminary experiments reported here were designed to examine three mechanisms that may underlie the reduction in growth rate occurring in the late regrowth phase; heritable non-lethal cellular damage, host immunity, delayed post-irradiation tissue and vascular damage. Based on retransplantation experiments and studies with immunosuppressed rats, neither heritable non-lethal damage nor host immune factors appear to influence the regrowth rate of tumors receiving radiation doses well below the cure level. After an x-ray dose approaching the cure level, regrowing tumors were observed to have a greatly reduced growth rate, possibly reflecting the presence of heritable non-lethal damage and/or an increased antigenicity of the heavily irradiated tumor cells. Morphometric analysis of histological sections did not reveal statistically significant abnormalities at the cellular level during the late regrowth phase, except for an increase in the percentage of necrotic tissue relative to non-irradiated tumors. The morphological resolution of small blood vessels was not adequate to evaluate delayed vascular damage in regrowing irradiated tumors

  10. The human body retention time of environmental organically bound Tritium : preliminary analysis of results from a volunteer study

    International Nuclear Information System (INIS)

    Hunt, John; Bailey, Trevor; Reese, Allan

    2008-01-01

    Tritium in the UK environment causes low radiation doses to the public, but uncertainty exists in the dose coefficient for the organically-bound component of tritium (OBT). This can affect the assessment of effective doses to representative persons. Contributing to that uncertainty is poor knowledge of the body retention time of OBT and how this varies for different OBT compounds in food. This study was undertaken to measure the retention time of tritium by volunteers after eating sole from Cardiff Bay, which may contain OBT from discharges from the GE Healthcare Ltd. plant. Five volunteers provided samples of excreta over periods up to 150 days after intake. Preliminary analysis of the results suggests retention of total tritium with body half-times ranging from 4 to 11 days, with no evidence of a significant contribution due to retention with a longer half-time. This range covers the half-time of 10 days used by the ICRP for tritiated water. The short timescale could be due to rapid hydrolysis in body tissues of the particular form of OBT used in this study. Implications for the dose coefficient for OBT are that the use of the ICRP value of 4.2 10- 11 Sv Bq -1 may be cautious in this specific situation, and the value of 1.6 10 -11 Sv Bq-1 used by the ICRP for tritiated water might even be more appropriate. These observations on dose coefficients are separate from any implications of recent discussion on whether the tritium radiation weighting factor should be increased from 1 to 2. (author)

  11. Noise and dose modeling for pediatric CT optimization: preliminary results

    International Nuclear Information System (INIS)

    Miller Clemente, Rafael A.; Perez Diaz, Marlen; Mora Reyes, Yudel; Rodriguez Garlobo, Maikel; Castillo Salazar, Rafael

    2008-01-01

    Full text: A Multiple Linear Regression Model was developed to predict noise and dose in computed tomography pediatric imaging for head and abdominal examinations. Relative values of Noise and Volumetric Computed Tomography Dose Index was used to estimate de model respectively. 54 images of physical phantoms were performed. Independent variables considered included: phantom diameter, tube current and kilovolts, x ray beam collimation, reconstruction diameter and equipment's post processing filters. Predicted values show good agreement with measurements, which were better in noise model (R 2 adjusted =0.953) than the dose model (R 2 adjusted =0.744). Tube current, object diameter, beam collimation and reconstruction filter were identified as the most influencing factors in models. (author)

  12. The Impact of a One-Dose versus Two-Dose Oral Cholera Vaccine Regimen in Outbreak Settings: A Modeling Study

    Science.gov (United States)

    Azman, Andrew S.; Luquero, Francisco J.; Ciglenecki, Iza; Grais, Rebecca F.; Sack, David A.; Lessler, Justin

    2015-01-01

    Background In 2013, a stockpile of oral cholera vaccine (OCV) was created for use in outbreak response, but vaccine availability remains severely limited. Innovative strategies are needed to maximize the health impact and minimize the logistical barriers to using available vaccine. Here we ask under what conditions the use of one dose rather than the internationally licensed two-dose protocol may do both. Methods and Findings Using mathematical models we determined the minimum relative single-dose efficacy (MRSE) at which single-dose reactive campaigns are expected to be as or more effective than two-dose campaigns with the same amount of vaccine. Average one- and two-dose OCV effectiveness was estimated from published literature and compared to the MRSE. Results were applied to recent outbreaks in Haiti, Zimbabwe, and Guinea using stochastic simulations to illustrate the potential impact of one- and two-dose campaigns. At the start of an epidemic, a single dose must be 35%–56% as efficacious as two doses to avert the same number of cases with a fixed amount of vaccine (i.e., MRSE between 35% and 56%). This threshold decreases as vaccination is delayed. Short-term OCV effectiveness is estimated to be 77% (95% CI 57%–88%) for two doses and 44% (95% CI −27% to 76%) for one dose. This results in a one-dose relative efficacy estimate of 57% (interquartile range 13%–88%), which is above conservative MRSE estimates. Using our best estimates of one- and two-dose efficacy, we projected that a single-dose reactive campaign could have prevented 70,584 (95% prediction interval [PI] 55,943–86,205) cases in Zimbabwe, 78,317 (95% PI 57,435–100,150) in Port-au-Prince, Haiti, and 2,826 (95% PI 2,490–3,170) cases in Conakry, Guinea: 1.1 to 1.2 times as many as a two-dose campaign. While extensive sensitivity analyses were performed, our projections of cases averted in past epidemics are based on severely limited single-dose efficacy data and may not fully capture

  13. Measurement the concentration of polonium 210Po and find annual dose resulting from eating certain foods by the individual Iraqi

    International Nuclear Information System (INIS)

    Al-Emam, A. M.; Mhemeed, A.K.; Hasan, H.I.

    2012-12-01

    The present study aims to determine the concentration of polonium 2 10P o in some of the food consumed by the Iraqi individual collecting (27) sample produced within the country, including imported and available in local markets to some Iraqi provinces, and these foods included potatoes, wheat and fish. To find concentration of polonium 2 10P o method is used chemical separation and deposition on silver disc, and use surface barrier detector to find alpha particle spectrum for polonium and find concentrations ere at 7.15, 2.58, 6.86 Bq / kg, for each of potatoes, wheat and fish, respectively, Daily intake rate for polotuinm 2 10P o which found in the food under study was measured, and show that the annual dose resulting from eating foods that contain this element was at 4.55, 87,69, 0.298 μSv/ y for food stuff mentioned are compatible with universal values and within the permissible limits worldwide. (Author)

  14. Preliminary pharmacological screening of Bixa orellana L. leaves.

    Science.gov (United States)

    Shilpi, Jamil Ahmad; Taufiq-Ur-Rahman, Md; Uddin, Shaikh Jamal; Alam, Md Shahanur; Sadhu, Samir Kumar; Seidel, Véronique

    2006-11-24

    Preliminary pharmacological studies were performed on the methanol extract of Bixa orellana L. (Bixaceae) leaves to investigate neuropharmacological, anticonvulsant, analgesic, antidiarrhoeal activity and effect on gastrointestinal motility. All studies were conducted in mice using doses of 125, 250 and 500 mg/kg of body weight. In the pentobarbitone-induced hypnosis test, the extract statistically reduced the time for the onset of sleep at 500 mg/kg dose and (dose-dependently) increased the total sleeping time at 250 and 500 mg/kg dose. A statistically significant decrease in locomotor activity was observed at all doses in the open-field and hole-cross tests. In the strychnine-induced anticonvulsant test, the extract increased the average survival time of the test animals (statistically significant at 250 and 500 mg/kg). The extract significantly and dose-dependently reduced the writhing reflex in the acetic acid-induced writhing test. Antidiarrhoeal activity was supported by a statistically significant decrease in the total number of stools (including wet stools) in castor oil-induced diarrhoea model. A statistically significant delay in the passage of charcoal meal was observed at 500 mg/kg in the gastrointestinal motility test. The extract was further evaluated in vitro for antioxidant and antibacterial activity. It revealed radical scavenging properties in the DPPH assay (IC(50)=22.36 microg/ml) and antibacterial activity against selected causative agents of diarrhoea and dysentery, including Shigella dysenteriae.

  15. Study of dose distribution in dental radiology using the Monte Carlo Simulation; Estudo da distribuicao de dose em radiologia odontologica usando simulacao Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Bonzoumet, S P.J.; Braz, D; Lopes, R T [Nuclear Instrumentation Laboratory, COPPE/UFRJ, Rio de Janeiro (Brazil); Anjos, M J [Nuclear Instrumentation Laboratory, COPPE/UFRJ, Rio de Janeiro (Brazil); Universidade do Estado do Rio de Janeiro, Rio de Janeiro (Brazil). Instituto de Fisica; Barroso, R C.S. [Universidade do Estado do Rio de Janeiro, Rio de Janeiro (Brazil). Instituto de Fisica

    2003-11-15

    Full text: The purpose of this study was to study the absorbed dose in mouth due to scattering in teeth in dental radiography using the monte carlo simulation. The Electron Gamma Shower (EGS-4) system of computer codes was used, which is a general purpose package for monte carlo simulation of the coupled transport of electrons and photons in an arbitrary geometry for particles with energies above a few keV up to several TeV. In the case of a X ray dental the low energy photons beam, are removed of the spectrum by the filtration. These low energy photons beam do not contribute in the obtaining of the radiographic image, but they will be contribute in the dose to the patient, however when the incident radiation crosses the tooth it generates a scattering radiation that contributes in the dose received by the patient in the oral cavity (cheek, tooth and oral cavity). Dental radiography is one of the largest single groups of radiographic examination accounting for 32% of radiographs taken in the Brazil. A number of relatively recent improvements in technology, equipment and techniques have the potential to reduce patient radiation dose and improve image quality. To optimize radiation protection all reasonable means should be employed to minimize the dose of each exposure. Dentists therefore need to keep up to date with changes in techniques and equipment and modify their own practice. In preliminary analysis could be notice that the energy below the 30 keV (low energy) is deposited in the cheek. To 30 keV photons there is the maximum absorbed energy in the tooth (about 60%). In 40 keV could be notice that deposited energy is same to teeth and cheek, but up to 40 keV just a small part of energy is deposited, e.g., the great part of energy is transmitted to the inner mouth (oral cavity). (orig.)

  16. A preliminary safety evaluation of polyhexamethylene guanidine hydrochloride.

    Science.gov (United States)

    Asiedu-Gyekye, Isaac Julius; Mahmood, Seidu Abdulai; Awortwe, Charles; Nyarko, Alexander Kwadwo

    2014-01-01

    Polyhexamethylene guanidine hydrochloride (PHMGH) is used worldwide as an antimicrobial agent with broad spectra of activity and also for treating pool water. This non-GLP preliminary study aims at investigating in a subchronic toxicity study possible effects at supra-optimal doses of this biocide. Both acute and subchronic toxicity studies were conducted. LD(50) for PHMGH was estimated to be 600 mg/kg (ie LC(50) 2 ml of 7.5% solution) when administered as a single dose by gavage via a stomach tube in accordance with the expected route of administration. The acute studies showed that the median lethal dose (LD(50)) of 600 mg/kg was accompanied by signs of neurotoxicity. Haematological and biochemical parameters of subchronic toxicity studies were non-significant. Subchronic doses of 0.006 mg/kg, 0.012 mg/kg and 0.036 mg/kg were administered. 20% of the animals at a dose of 0.006 mg/kg and 0.036 mg/kg showed mild degrees of hydropic changes in proximal tubules while 10% of animals at all the doses had their liver tissues showing local areas of mild pericentral hepatocytes degeneration. PHMGH did not produce any major organ defect with regard to the kidney, heart, and liver. The LD(50) was much higher than the recommended dosage by a factor of about 50,000. The recommended residual concentration is far less than the median lethal dose using rats as test subjects. These results could serve as a basis for investigating the full toxicological profile if it is to be used for the treatment of raw water to make it potable. © The Author(s) 2014.

  17. Absorbed dose to mice in prolonged irradiation by low-dose rate ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Shiragai, Akihiro [National Inst. of Radiological Sciences, Chiba (Japan); Saitou, Mikio; Kudo, Iwao [and others

    2000-07-01

    In this paper, the dose absorbed by mice was evaluated as a preliminary study of the late effects of prolonged continuous irradiation of mice with low-dose rate ionizing radiation. Eight-week-old male and female SPF C3H/HeN mice in three irradiation rooms were exposed to irradiation at 8000, 400, and 20 mGy, respectively, using a {sup 137}Cs {gamma}-source. Nine racks were arranged in a circle approximately 2.5 m from the source in each room, and 10 cages were arranged on the 4 shelves of each rack. Dose distributions, such as in air at the source level, in the three rooms were estimated by using ionization chambers, and the absorbed dose distributions in the room and relative dose distributions in the cages in relation to the distance of the cage center were examined. The mean abdomen doses of the mice measured by TLD were compared with the absorbed doses in the cages. The absorbed dose distributions showed not only inverse-inverse-square-law behavior with distance from the source, but geometric symmetry in every room. The inherent scattering and absorption in each room are responsible for such behavior and asymmetry. Comparison of relative dose distributions revealed cage positions that are not suitable for experiments with high precision doses, but all positions can be used for prolonged continuous irradiation experiments if the position of the cages is rotated regularly. The mean abdomen doses of the mice were similar in each cage. The mean abdomen doses of the mice and the absorbed doses in a cage were almost the same in all cages. Except for errors concerning the positions of the racks and cages, the uncertainties in the exposure doses were estimated to be about {+-}12% for 8000 mGy group, 17% for 400 mGy group, and 35% for 20 mGy group. (K.H.)

  18. Comparative study of eye dose and chest dose received during radiopharmaceutical production processes

    International Nuclear Information System (INIS)

    Chindarkar, A.S.; Chavan, S.V.; Sawant, D.K.; Sahoo, L.; Gopalakrishnan, R.K.; Sneha, C.; Sachdev, S.S.; Dey, A.C.

    2018-01-01

    Radiopharmaceutical laboratory, BRIT, Vashi produces different radiopharmaceuticals of 131 I, 153 Sm, 99 Mo/ 99m Tc and 177 Lu. Principle gamma energies of these isotopes vary from 103 to 740 KeV and their maximum beta energies vary from 384 to 1214 KeV. In the light of the revised eye lens dose limit recommended in IAEA Basic Safety Standard Interim Edition No. GSR Part 3 (IAEA-2011), the study of radiation dose for eye lens was carried out using CaSO 4 : Dy based Thermo luminescence dosimeter (TLD). This TLD was worn at center of the forehead to measure eye lens dose. This TLD dose was then compared with chest TLD dose to deduce any correlation between these TLD doses. These TLD doses were assessed on quarterly basis. Eight quarter data of these TLD doses were compared

  19. Functional magnetic resonance imaging (fMRI of attention processes in presumed obligate carriers of schizophrenia: preliminary findings

    Directory of Open Access Journals (Sweden)

    Morris Robin G

    2008-10-01

    Full Text Available Abstract Background Presumed obligate carriers (POCs are the first-degree relatives of people with schizophrenia who, although do not exhibit the disorder, are in direct lineage of it. Thus, this subpopulation of first-degree relatives could provide very important information with regard to the investigation of endophenotypes for schizophrenia that could clarify the often contradictory findings in schizophrenia high-risk populations. To date, despite the extant literature on schizophrenia endophenotypes, we are only aware of one other study that examined the neural mechanisms that underlie cognitive abnormalities in this group. The aim of this study was to investigate whether a more homogeneous group of relatives, such as POCs, have neural abnormalities that may be related to schizophrenia. Methods We used functional magnetic resonance imaging (fMRI to collect blood oxygenated level dependent (BOLD response data in six POCs and eight unrelated healthy controls while performing under conditions of sustained, selective and divided attention. Results The POCs indicated alterations in a widely distributed network of regions involved in attention processes, such as the prefrontal and temporal (including the parahippocampal gyrus cortices, in addition to the anterior cingulate gyrus. More specifically, a general reduction in BOLD response was found in these areas compared to the healthy participants during attention processes. Conclusion These preliminary findings of decreased activity in POCs indicate that this more homogeneous population of unaffected relatives share similar neural abnormalities with people with schizophrenia, suggesting that reduced BOLD activity in the attention network may be an intermediate marker for schizophrenia.

  20. Preliminary Study on the High Efficiency Supercritical Pressure Water-Cooled Reactor for Electricity Generation

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Yoon Yeong; Park, Jong Kyun; Cho, Bong Hyun and others

    2006-01-15

    This research has been performed to introduce a concept of supercritical pressure water cooled reactor(SCWR) in Korea The area of research includes core conceptual design, evaluation of candidate fuel, fluid systems conceptual design with mechanical consideration, preparation of safety analysis code, and construction of supercritical pressure heat transfer test facility, SPHINX, and preliminary test. As a result of the research, a set of tools for the reactor core design has been developed and the conceptual core design with solid moderator was proposed. The direct thermodynamic cycle has been studied to find a optimum design. The safety analysis code has also been adapted to supercritical pressure condition. A supercritical pressure CO2 heat transfer test facility has been constructed and preliminary test proved the facility works as expected. The result of this project will be good basis for the participation in the international collaboration under GIF GEN-IV program and next 5-year mid and long term nuclear research program of MOST. The heat transfer test loop, SPHINX, completed as a result of this project may be used for the power cycle study as well as further heat transfer study for the various geometries.

  1. Resilience in post-Katrina New Orleans, Louisiana: a preliminary study.

    Science.gov (United States)

    Glandon, Douglas M; Muller, Jocelyn; Almedom, Astier M

    2008-12-01

    Much scholarly and practitioner attention to the impact of Hurricane Katrina on the city of New Orleans, Louisiana has focused on the failures of government disaster prevention and management at all levels, often overlooking the human strength and resourcefulness observed in individuals and groups among the worst-affected communities. This preliminary study sought to investigate human resilience in the city of New Orleans, State of Louisiana, eighteen months after Hurricane Katrina struck the Mississippi delta region. The Sense of Coherence scale, short form (SOC-13) was administered to a sample of 41 residents of Lower Ninth Ward and adjacent Wards who had been displaced by Hurricane Katrina but were either living in or visiting their home area during March 2007. Study participants were recruited through the local branch of the Association of Community Organizations for Reform Now (ACORN), a nation-wide grassroots organization whose mission is to promote the housing rights of low and moderate-income individuals and families across the USA and in several other countries. Those who had returned to their homes had significantly higher SOC scores compared to those who were still displaced (p<0.001). Among the latter, those who were members of ACORN scored significantly higher than non-members (p<0.005), and their SOC-13 scores were not significantly different from the scores of study participants who had returned home (including both members and non-members of ACORN). The findings of this preliminary study concur with previous reports in the literature on the deleterious impact of displacement on individual and collective resilience to disasters. Relevant insight gleaned from the qualitative data gathered during the course of administering the SOC-13 scale compensate for the limitations of the small sample size as they draw attention to the importance of the study participants' sources of social support. Possible avenues for further research are outlined.

  2. Uncertainties on lung doses from inhaled plutonium.

    Science.gov (United States)

    Puncher, Matthew; Birchall, Alan; Bull, Richard K

    2011-10-01

    In a recent epidemiological study, Bayesian uncertainties on lung doses have been calculated to determine lung cancer risk from occupational exposures to plutonium. These calculations used a revised version of the Human Respiratory Tract Model (HRTM) published by the ICRP. In addition to the Bayesian analyses, which give probability distributions of doses, point estimates of doses (single estimates without uncertainty) were also provided for that study using the existing HRTM as it is described in ICRP Publication 66; these are to be used in a preliminary analysis of risk. To infer the differences between the point estimates and Bayesian uncertainty analyses, this paper applies the methodology to former workers of the United Kingdom Atomic Energy Authority (UKAEA), who constituted a subset of the study cohort. The resulting probability distributions of lung doses are compared with the point estimates obtained for each worker. It is shown that mean posterior lung doses are around two- to fourfold higher than point estimates and that uncertainties on doses vary over a wide range, greater than two orders of magnitude for some lung tissues. In addition, we demonstrate that uncertainties on the parameter values, rather than the model structure, are largely responsible for these effects. Of these it appears to be the parameters describing absorption from the lungs to blood that have the greatest impact on estimates of lung doses from urine bioassay. Therefore, accurate determination of the chemical form of inhaled plutonium and the absorption parameter values for these materials is important for obtaining reliable estimates of lung doses and hence risk from occupational exposures to plutonium.

  3. A Study on the Establishment of Radiation Dose Estimation Procedure for Accumulated Radioactive Ions for RAON ISOL System

    Directory of Open Access Journals (Sweden)

    KIM Do Hyun

    2017-01-01

    Full Text Available For purposes of various experiments, RAON heavy ion accelerator facility has been designed in Korea. ISOL is one system of RAON accelerators to generate and separate rare isotopes. Radioactive ions generated from target-proton reactions are separated and accumulated at separation devices. The accumulated isotopes release the gamma radiations; therefore, the radiation safety must be clearly estimated. In this study, a process to evaluate radiations from the accumulated ions was proposed by modifying FISPACT code. The proposed process was validated by comparing a solution of single element decay problem. Using the process, a preliminary study for radiation doses were performed in a virtual separation devise.

  4. Assessing levels of similarity to a "psychodynamic prototype" in psychodynamic psychotherapy with children: a case study approach (preliminary findings

    Directory of Open Access Journals (Sweden)

    Marina Bento Gastaud

    2015-09-01

    Full Text Available Objective:To analyze the degree of similarity to a "psychodynamic prototype" during the first year of two children's once-weekly psychodynamic psychotherapy.Methods: This study used a longitudinal, descriptive, repeated-measures design based on the systematic case study method. Two male school children (here referred to as Walter and Peter and their therapists took part in the study. All sessions were video and audio recorded. Ten sessions from each case were selected for analysis in this preliminary study. Trained examiners (randomly selected in pairs independently and blindly evaluated each session using the Child Psychotherapy Q-Set (CPQ. Experts in psychodynamic therapy and cognitive behavioral therapy from several countries rated each of the 100 CPQ items with regard to how well it characterized a hypothetical ideal session of either treatment modality. A series of paired t tests comparing analogous adherence scores within each session were conducted.Results:There were no significant correlations between time elapsed and adherence to the prototypes. Walter's treatment adhered to both prototypes and Peter's treatment did not adhere to either prototype.Conclusion:Child psychotherapy theory and practice are not absolutely coincident. Real psychotherapy sessions do not necessarily resemble the ideal prototypes.

  5. Millennials, entrepreneurs and the Hungarian workplace of the future the preliminary findings of a pilot study

    OpenAIRE

    Chandler, Nick

    2015-01-01

    Existing research into generational differences in Hungary was based primarily on adapting findings from studies undertaken in Western Countries. If we consider not only the comparative history and wealth but also the cultural differences between Hungary and the countries in which these studies took place, then the apparent adaptability is brought into question. This study aims to examine the nature of millennial students in Hungary by building up the characteristics from the grou...

  6. Population dose and health impact of the accident at the Three Mile Island Nuclear Station. Preliminary estimates for the period March 28, 1979--April 7, 1979

    International Nuclear Information System (INIS)

    Battist, L.; Congel, F.; Buchanan, J.; Peterson, H.

    1979-05-01

    This report contains a preliminary assessment of the radiation dose and potential health impact of the accident on March 28, 1979 at the Three Mile Island Nuclear Station. This assessment was prepared by a task group composed of technical staff members from The Environmental Protection Agency, The Department of Health, Education and Welfare, and The Nuclear Regulatory Commission. The estimated dose that might have been received by an individual is less than 100 mrem. The collective dose received by the 2,164,000 people estimated to live within 50 miles of the reactor site is calculated to be 3,300 person-rem (with a range of 1600 to 5300 person-rem). This corresponds to an average dose of approximately 1.5 mrem. The potential number of fatal cancers that is projected to occur as a result of the accident is less than 1. This potential impact would be undetectable compared to the 325,000 cancer deaths that would normally be expected to occur in a population of 2,164,000. The estimated total health impact, including fatal and non-fatal cancers and genetic effects to all future generations is approximately 2 health effects

  7. A preliminary study of aquaporin 1 immunolocalization in chronic subdural hematoma membranes.

    Science.gov (United States)

    Basaldella, Luca; Perin, Alessandro; Orvieto, Enrico; Marton, Elisabetta; Itskevich, David; Dei Tos, Angelo Paolo; Longatti, Pierluigi

    2010-07-01

    Aquaporin 1 (AQP1) is a molecular water channel expressed in many anatomical locations, particularly in epithelial barriers specialized in water transport. The aim of this study was to investigate AQP1 expression in chronic subdural hematoma (CSDH) membranes. In this preliminary study, 11 patients with CSDH underwent burr hole craniectomy and drainage. Membrane specimens were stained with a monoclonal antibody targeting AQP1 for immunohistochemical analysis. The endothelial cells of the sinusoid capillaries of the outer membranes exhibited an elevated immunoreactivity to AQP1 antibody compared to the staining intensity of specimens from the inner membrane and normal dura. These findings suggest that the outer membrane might be the source of the increased fluid accumulation responsible for chronic hematoma enlargement.

  8. High-dose-rate stereotactic body radiation therapy for postradiation therapy locally recurrent prostatic carcinoma: Preliminary prostate-specific antigen response, disease-free survival, and toxicity assessment.

    Science.gov (United States)

    Fuller, Donald B; Wurzer, James; Shirazi, Reza; Bridge, Stephen S; Law, Jonathan; Mardirossian, George

    2015-01-01

    Patients with locally recurrent adenocarcinoma of the prostate following radiation therapy (RT) present a challenging problem. We prospectively evaluated the use of "high-dose-rate-like" prostate stereotactic body RT (SBRT) salvage for this circumstance, evaluating prostate-specific antigen response, disease-free survival, and toxicity. Between February 2009 and March 2014, 29 patients with biopsy-proven recurrent locally prostate cancer >2 years post-RT were treated. Median prior RT dose was 73.8 Gy and median interval to SBRT salvage was 88 months. Median recurrence Gleason score was 7 (79% was ≥7). Pre-existing RT toxicity >grade 1 was a reason for exclusion. Magnetic resonance imaging-defined prostate volume including any suspected extraprostatic extension, comprising the planning target volume. A total of 34 Gy/5 fractions was given, delivering a heterogeneous, high-dose-rate-like dose-escalation pattern. Toxicities were assessed using Common Terminology Criteria for Adverse Events, version 3.0, criteria. Twenty-nine treated patients had a median 24-month follow-up (range, 3-60 months). A median pre-SBRT salvage baseline prostate-specific antigen level of 3.1 ng/mL decreased to 0.65 ng/mL and 0.16 ng/mL at 1 and 2 years, respectively. Actuarial 2-year biochemical disease-free survival measured 82%, with no local failures. Toxicity >grade 1 was limited to the genitourinary domain, with 18% grade 2 or higher and 7% grade 3 or higher. No gastrointestinal toxicity >grade 1 occurred. Two-year disease-free survival is encouraging, and the prostate-specific antigen response kinetic appears comparable with that seen in de novo patients treated with SBRT, albeit still a preliminary finding. Grade ≥2 genitourinary toxicity was occasionally seen with no obvious predictive factor. Noting that our only brachytherapy case was 1 of the 2 cases with ≥grade 3 genitourinary toxicity, caution is recommended treating these patients. SBRT salvage of post-RT local recurrence

  9. Single visit rabies pre-exposure priming induces a robust anamnestic antibody response after simulated post-exposure vaccination: results of a dose-finding study.

    Science.gov (United States)

    Jonker, Emile F F; Visser, Leonardus G

    2017-09-01

    The current standard 3-dose intramuscular rabies PrEP schedule suffers from a number of disadvantages that severely limit accessibility and availability. The cost of is often prohibitive, it requires 3 visits to the clinic, and there are regular vaccine shortages. Volunteers ( N  = 30) were randomly assigned to 4 study arms: 1 standard dose intramuscular (IM) dose of PVRV (purified Vero cell rabies vaccine, Verorab), and 1/5th, 2/5th or 3/5th- fractional intradermal (ID) dose of PVRV in a single visit. All subjects received a simulated rabies post-exposure prophylaxis (D0, D3) 1 year later. Rabies virus neutralizing antibodies (RVNA) were determined by virus neutralization microtest (FAVN) on D0, D7, D28, Y1 and Y1 + D7. 28 out of 30 subjects (93%) seroconverted 1 month after primary vaccination; 1 subject in the 1-dose IM arm and 1 in the 1/5th-fractional dose ID arm did not. After 1 year, 22 out of 30 subjects (73%) no longer had RVNA above 0.5 IU/ml, with no discernible difference between study groups. After 1 year, all 30 subjects mounted a booster response within 7 days after simulated PEP, with the highest titers found in the single dose IM group ( P  rabies vaccine was sufficient to induce an adequate anamnestic antibody response to rabies PEP in all subjects 1 year later, even in those in whom the RVNA threshold of 0.5 IU/ml was not reached after priming. © International Society of Travel Medicine, 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  10. Radiological dose assessment related to management of naturally occurring radioactive materials generated by the petroleum industry

    International Nuclear Information System (INIS)

    Smith, K.P.; Blunt, D.L.; Williams, G.P.; Tebes, C.L.

    1995-01-01

    A preliminary radiological dose assessment related to equipment decontamination, subsurface disposal, landspreading, equipment smelting, and equipment burial was conducted to address concerns regarding the presence of naturally occurring radioactive materials in production waste streams. The assessment evaluated the relative dose of these activities and included a sensitivity analysis of certain input parameters. Future studies and potential policy actions are recommended

  11. Preliminary Sensitivity Study on Gas-Cooled Reactor for NHDD System Using MARS-GCR

    International Nuclear Information System (INIS)

    Lee, Seung Wook; Jeong, Jae Jun; Lee, Won Jae

    2005-01-01

    A Gas-Cooled Reactor (GCR) is considered as one of the most outstanding tools for a massive hydrogen production without CO 2 emission. Till now, two types of GCR are regarded as a viable nuclear reactor for a hydrogen production: Prismatic Modular Reactor (PMR), Pebble Bed Reactor (PBR). In this paper, a preliminary sensitivity study on two types of GCR is carried out by using MARS-GCR to find out the effect on the peak fuel and reactor pressure vessel (RPV) temperature, with varying the condition of a reactor inlet, outlet temperature, and system pressure for both PMR and PBR

  12. Articulation Rate and Vowel Space Characteristics of Young Males with Fragile X Syndrome: Preliminary Acoustic Findings

    Science.gov (United States)

    Zajac, David J.; Roberts, Joanne E.; Hennon, Elizabeth A.; Harris, Adrianne A.; Barnes, Elizabeth F.; Misenheimer, Jan

    2006-01-01

    Purpose: Increased speaking rate is a commonly reported perceptual characteristic among males with fragile X syndrome (FXS). The objective of this preliminary study was to determine articulation rate--one component of perceived speaking rate--and vowel space characteristics of young males with FXS. Method: Young males with FXS (n = 38), …

  13. High doses of biotin in chronic progressive multiple sclerosis: a pilot study.

    Science.gov (United States)

    Sedel, Frédéric; Papeix, Caroline; Bellanger, Agnès; Touitou, Valérie; Lebrun-Frenay, Christine; Galanaud, Damien; Gout, Olivier; Lyon-Caen, Olivier; Tourbah, Ayman

    2015-03-01

    No drug has been found to have any impact on progressive multiple sclerosis (MS). Biotin is a vitamin acting as a coenzyme for carboxylases involved in key steps of energy metabolism and fatty acids synthesis. Among others, biotin activates acetylCoA carboxylase, a potentially rate-limiting enzyme in myelin synthesis. The aim of this pilot study is to assess the clinical efficacy and safety of high doses of biotin in patients suffering from progressive MS. Uncontrolled, non-blinded proof of concept study 23 consecutive patients with primary and secondary progressive MS originated from three different French MS reference centers were treated with high doses of biotin (100-300mg/day) from 2 to 36 months (mean=9.2 months). Judgement criteria varied according to clinical presentations and included quantitative and qualitative measures. In four patients with prominent visual impairment related to optic nerve injury, visual acuity improved significantly. Visual evoked potentials in two patients exhibited progressive reappearance of P100 waves, with normalization of latencies in one case. Proton magnetic resonance spectroscopy (H-MRS) in one case showed a progressive normalization of the Choline/Creatine ratio. One patient with left homonymous hemianopia kept on improving from 2 to 16 months following treatment׳s onset. Sixteen patients out of 18 (89%) with prominent spinal cord involvement were considered as improved as confirmed by blinded review of videotaped clinical examination in 9 cases. In all cases improvement was delayed from 2 to 8 months following treatment׳s onset. These preliminary data suggest that high doses of biotin might have an impact on disability and progression in progressive MS. Two double-blind placebo-controlled trials are on going. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  14. A Dose-Finding Study of Dexketoprofen in Patients Undergoing Laparoscopic Cholecystectomy: A Randomized Clinical Trial on Effects on the Analgesic Concentration of Oxycodone.

    Science.gov (United States)

    Piirainen, Annika; Kokki, Hannu; Immonen, Satu; Eskelinen, Matti; Häkkinen, Merja R; Hautajärvi, Heidi; Kokki, Merja

    2015-12-01

    Dexketoprofen has been shown to provide efficient analgesia and an opioid-sparing effect after orthopedic surgery. In this dose-finding study, we evaluated the analgesic efficacy and opioid-sparing effect of dexketoprofen administered intravenously (i.v.) after laparoscopic cholecystectomy (LCC). Twenty-four patients undergoing LCC were randomized to receive dexketoprofen 10 or 50 mg i.v. 15 min before the end of the surgery. Subjects were provided with 0.2 mg/kg of oxycodone at anesthesia induction. In the recovery room, pain was assessed with an 11-point numerical rating scale (NRS; score of 0 = no pain, score of 10 = most severe pain) every 10 min. When the NRS score was ≥3/10 at rest or ≥5/10 at wound compression, a plasma sample was taken for analysis of oxycodone [to determine the minimum effective concentration (MEC)], its metabolites, and dexketoprofen. After that, subjects were titrated with oxycodone 2 or 3 mg i.v. every 10 min until the NRS score was dexketoprofen. At the onset of pain, the plasma oxycodone concentrations (MEC) were similar in the two groups: median 60 ng/mL (range 37-73) in the 10 mg group and median 52 ng/mL (range 24-79) in the 50 mg group. At the time of pain relief, the MEACs were 98 ng/mL (range 59-150) in the 10 mg group and 80 ng/mL (range 45-128) in the 50 mg group. The total doses of oxycodone needed to achieve pain relief were similar: 0.11 mg/kg (range 0-0.33) in the 10 mg group and 0.08 mg/kg (range 0-0.24) in the 50 mg group. Eleven subjects developed mild desaturation or a decreased respiratory rate after oxycodone titration. In the present double-blinded, randomized clinical trial, the need for a rescue opioid analgesic, oxycodone, was similar with the two dose levels of dexketoprofen-10 and 50 mg i.v.-after LCC.

  15. SU-C-204-06: Monte Carlo Dose Calculation for Kilovoltage X-Ray-Psoralen Activated Cancer Therapy (X-PACT): Preliminary Results

    Energy Technology Data Exchange (ETDEWEB)

    Mein, S [Duke University Medical Physics Graduate Program (United States); Gunasingha, R [Department of Radiation Safety, Duke University Medical Center (United States); Nolan, M [Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University (United States); Oldham, M; Adamson, J [Department of Radiation Oncology, Duke University Medical Center (United States)

    2016-06-15

    Purpose: X-PACT is an experimental cancer therapy where kV x-rays are used to photo-activate anti-cancer therapeutics through phosphor intermediaries (phosphors that absorb x-rays and re-radiate as UV light). Clinical trials in pet dogs are currently underway (NC State College of Veterinary Medicine) and an essential component is the ability to model the kV dose in these dogs. Here we report the commissioning and characterization of a Monte Carlo (MC) treatment planning simulation tool to calculate X-PACT radiation doses in canine trials. Methods: FLUKA multi-particle MC simulation package was used to simulate a standard X-PACT radiation treatment beam of 80kVp with the Varian OBI x-ray source geometry. The beam quality was verified by comparing measured and simulated attenuation of the beam by various thicknesses of aluminum (2–4.6 mm) under narrow beam conditions (HVL). The beam parameters at commissioning were then corroborated using MC, characterized and verified with empirically collected commissioning data, including: percent depth dose curves (PDD), back-scatter factors (BSF), collimator scatter factor(s), and heel effect, etc. All simulations were conducted for N=30M histories at M=100 iterations. Results: HVL and PDD simulation data agreed with an average percent error of 2.42%±0.33 and 6.03%±1.58, respectively. The mean square error (MSE) values for HVL and PDD (0.07% and 0.50%) were low, as expected; however, longer simulations are required to validate convergence to the expected values. Qualitatively, pre- and post-filtration source spectra matched well with 80kVp references generated via SPEKTR software. Further validation of commissioning data simulation is underway in preparation for first-time 3D dose calculations with canine CBCT data. Conclusion: We have prepared a Monte Carlo simulation capable of accurate dose calculation for use with ongoing X-PACT canine clinical trials. Preliminary results show good agreement with measured data and hold

  16. Lung cancer screening with low-dose CT

    International Nuclear Information System (INIS)

    Diederich, S.; Wormanns, D.; Heindel, W.

    2003-01-01

    Screening for lung cancer is hoped to reduce mortality from this common tumour, which is characterised by a dismal overall survival, relatively well defined risk groups (mainly heavy cigarette smokers and workers exposed to asbestos) and a lack of early symptoms. In the past studies using sputum cytology and chest radiography have failed to demonstrate any reduction in lung cancer mortality through screening. One of the reasons is probably the relatively poor sensitivity of both these tests in early tumours. Low radiation dose computed tomography (CT) has been shown to have a much higher sensitivity for small pulmonary nodules, which are believed to be the most common presentation of early lung cancer. As, however, small pulmonary nodules are common and most are not malignant, non-invasive diagnostic algorithms are required to correctly classify the detected lesions and avoid invasive procedures in benign nodules. Nodule density, size and the demonstration of growth at follow-up have been shown to be useful in this respect and may in the future be supplemented by contrast-enhanced CT and positron emission tomography. Based on these diagnostic algorithms preliminary studies of low-dose CT in heavy smokers have demonstrated a high proportion of asymptomatic, early, resectable cancers with good survival. As, however, several biases could explain these findings in the absence of the ultimate goal of cancer screening, i.e. mortality reduction, most researchers believe that randomised controlled trials including several 10000 subjects are required to demonstrate a possible mortality reduction. Only then general recommendations to screen individuals at risk of lung cancer with low-dose CT should be made. It can be hoped that international cooperation will succeed in providing results as early as possible

  17. Pathology of gastric lesions in donkeys: A preliminary study.

    Science.gov (United States)

    Al-Mokaddem, A K; Ahmed, K A; Doghaim, R E

    2015-11-01

    Donkeys (Equus africanus asinus) are important working animals, particularly in countries where the majority of the population lives below the poverty line. Gastric ulceration has been shown to be common in British donkeys but donkeys from other parts of the world have not been as extensively researched. This study was performed as a preliminary overview of the severity and distribution of gastric lesions in mature donkeys and to document which parasites were present. Descriptive study of pathological findings. Stomachs of 35 mature draught donkeys were examined grossly and histopathology samples taken from 5 regions of the gastric mucosa. Gross examination revealed hyperaemia, oedema, erosions and ulcers in addition to parasitic lesions. Histopathological examination revealed hyperkeratosis, acanthosis, vacuolar degeneration of stratified squamous cells, gastritis, erosions, ulcerations, scarring, hyperactivity of mucus glands, periglandular fibroplasia and parasitic granulomes with infestation by Gasterophilus spp. larvae, Habronema spp. and Draschia megastoma. In donkeys, ulceration of the nonglandular regions of the stomach is more prominent than the glandular regions and parasitic infestations were frequent. © 2014 EVJ Ltd.

  18. Developing milk industry estimates for dose reconstruction projects

    International Nuclear Information System (INIS)

    Beck, D.M.; Darwin, R.F.

    1991-01-01

    One of the most important contributors to radiation doses from hanford during the 1944-1947 period was radioactive iodine. Consumption of milk from cows that ate vegetation contaminated with iodine is likely the dominant pathway of human exposure. To estimate the doses people could have received from this pathway, it is necessary to reconstruct the amount of milk consumed by people living near Hanford, the source of the milk, and the type of feed that the milk cows ate. This task is challenging because the dairy industry has undergone radical changes since the end of World War 2, and records that document the impact of these changes on the study area are scarce. Similar problems are faced by researchers on most dose reconstruction efforts. The purpose of this work is to document and evaluate the methods used on the Hanford Environmental Dose Reconstruction (HEDR) Project to reconstruct the milk industry and to present preliminary results

  19. Does low-dose CCK-8 injection produce abdominal pain in 'truly normal' individuals?

    International Nuclear Information System (INIS)

    Ramsay, S.; Webb, B.; Hille, N.

    1999-01-01

    Full text: The development of abdominal pain following cholecystokinin (CCK) injection is not specific for biliary disease. Patients can develop abdominal pain with CCK during hepatobiliary studies and have normal gallbladder function. Does this non-biliary pain indicate pathology? High doses of CCK induce pain in functional bowel syndromes, but may also produce pain in normals. Pain is less common at lower CCK doses, and hence may be more significant. This study aimed to determine the rate at which the low dose of CCK used in hepatobiliary scans causes abdominal pain and other side-effects in 'truly normal' individuals. Some preliminary results of CCK-induced pain in gastro-oesophageal reflux (GOR) patients are also discussed. Six 'truly normal' subjects were studied. 'Truly normal' was defined as: no current history of abdominal pain; no biliary or gallbladder disease; no significant GIT pathology; not currently on medication designed to be pharmacologically active in the GIT. Each patient was given an intravenous dose of 0.01 μg-kg -1 of CCK8 over 3 min, and side-effects were recorded for 30 min. No subject had abdominal pain. Two developed nausea, 1 moderate and 1 mild. An identical dose of CCK was given to 2 patients with endoscopically proven GOR. Anti-reflux medication had been ceased for 12 h. After CCK, 1 patient developed typical 'reflux' pain and 1 was asymptomatic. In conclusion, none of our 'truly normal' patients had abdominal pain with low-dose CCK. This suggests that patients developing pain following injection of this dose of CCK are indeed abnormal. The literature infers these patients may have irritable bowel syndrome; however, this hypothesis is complicated by our preliminary results indicating that CCK can reproduce pain in some patients with GOR

  20. Duration of post-vaccination immunity to yellow fever in volunteers eight years after a dose-response study.

    Science.gov (United States)

    de Menezes Martins, Reinaldo; Maia, Maria de Lourdes S; de Lima, Sheila Maria Barbosa; de Noronha, Tatiana Guimarães; Xavier, Janaina Reis; Camacho, Luiz Antonio Bastos; de Albuquerque, Elizabeth Maciel; Farias, Roberto Henrique Guedes; da Matta de Castro, Thalita; Homma, Akira

    2018-06-27

    In 2009, Bio-Manguinhos conducted a dose-response study with the yellow fever vaccine, administering the vaccine in the usual mean dose of 27,476 IU (full dose, reference) and in tapered doses (10,447 IU, 3013 IU, 587 IU, 158 IU, and 31 IU) by the usual subcutaneous route and usual volume (0.5 mL). Tapered doses were obtained by dilution in the manufacturer's laboratory, and the test batches presented industrial quality. Doses down to 587 IU showed similar immunogenicity to the full dose (27,476, reference), while the 158 IU and 31 IU doses displayed lower immunogenicity. Seropositivity was maintained at 10 months, except in the group that received the 31 IU dose. The current study aims to determine whether yellow fever seropositivity was maintained eight years after YF vaccination in non-revaccinated individuals. According to the current study's results, seropositivity was maintained in 85% of 318 participants and was similar across groups. The findings support the use of the yellow fever vaccine in fractional doses during outbreaks, but each fractional dose should have at least 587 IU. This study also supports the minimum dose required by WHO, 1000 IU. Clinicaltrials.gov NCT 03338231. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Aspects of pre-dose and other luminescence phenomena in quartz absorbed dose estimation

    International Nuclear Information System (INIS)

    Adamiec, G.

    2000-01-01

    The understanding of all luminescence processes occurring in quartz is of paramount importance in the further development of robust absorbed dose estimation techniques (for the purpose of dating and retrospective dosimetry). The findings presented in this thesis, aid future improvements of absorbed dose estimation techniques using quartz by presenting investigations in the following areas: 1) interpretation of measurement results, 2) numerical modelling of luminescence in quartz, 3) phenomena needing inclusion in future physical models of luminescence. In the first part, the variability of properties of single quartz grains is examined. Through empirical and theoretical considerations, investigations are made of various problems of measurements of luminescence using multi-grain aliquots, and specifically areas where the heterogeneity of the sample at the inter-grain level may be misinterpreted at the multi-grain-aliquot level. The results obtained suggest that the heterogeneity of samples is often overlooked, and that such differences can have a profound influence on the interpretation of measurement results. Discussed are the shape of TL glow curves, OSL decay curves, dose response curves (including consequences for using certain signals as proxies for others), normalisation procedures and D E estimation techniques. Further, a numerical model of luminescence is proposed, which includes multiple R-centres and is used to describe the pre-dose sensitisation in quartz. The numerical model exhibits a broad-scale behaviour observed experimentally in a sample of annealed quartz. The shapes of TAC for lower (20 Gy) and higher doses (1 kGy) and the evolution with temperature of the isothermal sensitisation curves are qualitatively matched for the empirical and numerical systems. In the third area, a preliminary investigation of the properties of the '110 deg. C peak' in the 550 nm emission band, in annealed quartz is presented. These properties are in sharp contrast with

  2. A phase 2a randomized, parallel group, dose-ranging study of molindone in children with attention-deficit/hyperactivity disorder and persistent, serious conduct problems.

    Science.gov (United States)

    Stocks, Jennifer Dugan; Taneja, Baldeo K; Baroldi, Paolo; Findling, Robert L

    2012-04-01

    To evaluate safety and tolerability of four doses of immediate-release molindone hydrochloride in children with attention-deficit/hyperactivity disorder (ADHD) and serious conduct problems. This open-label, parallel-group, dose-ranging, multicenter trial randomized children, aged 6-12 years, with ADHD and persistent, serious conduct problems to receive oral molindone thrice daily for 9-12 weeks in four treatment groups: Group 1-10 mg (5 mg if weight conduct problems. Secondary outcome measures included change in Nisonger Child Behavior Rating Form-Typical Intelligence Quotient (NCBRF-TIQ) Conduct Problem subscale scores, change in Clinical Global Impressions-Severity (CGI-S) and -Improvement (CGI-I) subscale scores from baseline to end point, and Swanson, Nolan, and Pelham rating scale-revised (SNAP-IV) ADHD-related subscale scores. The study randomized 78 children; 55 completed the study. Treatment with molindone was generally well tolerated, with no clinically meaningful changes in laboratory or physical examination findings. The most common treatment-related adverse events (AEs) included somnolence (n=9), weight increase (n=8), akathisia (n=4), sedation (n=4), and abdominal pain (n=4). Mean weight increased by 0.54 kg, and mean body mass index by 0.24 kg/m(2). The incidence of AEs and treatment-related AEs increased with increasing dose. NCBRF-TIQ subscale scores improved in all four treatment groups, with 34%, 34%, 32%, and 55% decreases from baseline in groups 1, 2, 3, and 4, respectively. CGI-S and SNAP-IV scores improved over time in all treatment groups, and CGI-I scores improved to the greatest degree in group 4. Molindone at doses of 5-20 mg/day (children weighing <30 kg) and 20-40 mg (≥ 30 kg) was well tolerated, and preliminary efficacy results suggest that molindone produces dose-related behavioral improvements over 9-12 weeks. Additional double-blind, placebo-controlled trials are needed to further investigate molindone in this pediatric population.

  3. Dose-reduction techniques for high-dose worker groups in nuclear power plants

    International Nuclear Information System (INIS)

    Khan, T.A.; Baum, J.W.; Dionne, B.J.

    1991-03-01

    This report summarizes the main findings of a study of the extent of radiation dose received by special work groups in the nuclear power industry. Work groups which chronically get large doses were investigated, using information provided by the industry. The tasks that give high doses to these work groups were examined and techniques described that were found to be particularly successful in reducing dose. Quantitative information on the extent of radiation doses to various work groups shows that significant numbers of workers in several critical groups receive doses greater than 1 and even 2 rem per year, particularly contract personnel and workers at BWR-type plants. The number of radiation workers whose lifetime dose is greater than their age is much less. Although the techniques presented would go some way in reducing dose, it is likely that a sizeable reduction to the high-dose work groups may require development of new dose-reduction techniques as well as major changes in procedures. 10 refs., 26 tabs

  4. Influence of radioprotectors on total body weight evolution and on oxygen consumption in lethal dose irradiated animals. (Preliminary study)

    International Nuclear Information System (INIS)

    Fatome, M.; Martine, G.; Bargy, E.; Andrieu, L.

    Comparison of total body weight evolution and oxygen consumption in lethal dose irradiated animals, protected by various well known radioprotective substances, isolated or in mixture, with evolution and consumption of non protected animals irradiated at the same dose and with these of check animals [fr

  5. Preliminary simulation study of doppler reflectometry

    International Nuclear Information System (INIS)

    Ishii, Yuta; Hojo, Hitoshi; Yoshikawa, Masashi; Ichimura, Makoto; Haraguchi, Yusuke; Imai, Tsuyoshi; Mase, Atsushi

    2010-01-01

    A preliminary simulation study of Doppler reflectometry is performed. The simulations solve Maxwell's equations by a finite difference time domain (FDTD) code method in two dimensions. A moving corrugated metal target is used as a plasma cutoff layer to study the basic features of Doppler reflectometry. We examined the effects of the full width at half maximum (FWHM) of the electromagnetic waves and the corrugation depth of the metal target. Furthermore, the effect of a nonuniform plasma is studied using this FDTD analysis. The Doppler shift and velocity are compared with those obtained from FDTD analysis of a uniform plasma. (author)

  6. Preliminary closed Brayton cycle study for a space reactor application

    International Nuclear Information System (INIS)

    Guimaraes, Lamartine Nogueira Frutuoso; Carvalho, Ricardo Pinto de; Camillo, Giannino Ponchio

    2007-01-01

    The Nuclear Energy Division (ENU) of the Institute for Advanced Studies (IEAv) has started a preliminary design study for a Closed Brayton Cycle Loop (CBCL) aimed at a space reactor application. The main objectives of the study are to establish a starting concept for the CBCL components specifications, and to develop a demonstrative simulator of CBCL in nominal operation conditions. The ENU/IEAv preliminary design study is developing the CBCL around the NOELLE 60290 turbo machine. The actual nuclear reactor study is being conducted independently. Because of that, a conventional heat source is being used for the CBCL, in this preliminary design phase. This paper describes the steady state simulator of the CBCL operating with NOELLE 60290 turbo machine. In principle, several gases are being considered as working fluid, as for instance: air, helium, nitrogen, CO2 and gas mixtures such as helium and xenon. At this moment the simulator is running with Helium as the working fluid. Simplified models of heat and mass transfer are being developed to simulate thermal components. Future efforts will focus on keeping track of the modifications being implemented at the NOELLE 60290 turbo machine in order to build the CBCL. (author)

  7. Preliminary closed Brayton cycle study for a space reactor application

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Lamartine Nogueira Frutuoso; Carvalho, Ricardo Pinto de [Institute for Advanced Studies, Sao Jose dos Campos, SP (Brazil)]. E-mail: guimarae@ieav.cta.br; Camillo, Giannino Ponchio [Instituto Tecnologico de Aeronautica (ITA), Sao Jose dos Campos, SP (Brazil)]. E-mail: gianninocamillo@gmail.com

    2007-07-01

    The Nuclear Energy Division (ENU) of the Institute for Advanced Studies (IEAv) has started a preliminary design study for a Closed Brayton Cycle Loop (CBCL) aimed at a space reactor application. The main objectives of the study are to establish a starting concept for the CBCL components specifications, and to develop a demonstrative simulator of CBCL in nominal operation conditions. The ENU/IEAv preliminary design study is developing the CBCL around the NOELLE 60290 turbo machine. The actual nuclear reactor study is being conducted independently. Because of that, a conventional heat source is being used for the CBCL, in this preliminary design phase. This paper describes the steady state simulator of the CBCL operating with NOELLE 60290 turbo machine. In principle, several gases are being considered as working fluid, as for instance: air, helium, nitrogen, CO2 and gas mixtures such as helium and xenon. At this moment the simulator is running with Helium as the working fluid. Simplified models of heat and mass transfer are being developed to simulate thermal components. Future efforts will focus on keeping track of the modifications being implemented at the NOELLE 60290 turbo machine in order to build the CBCL. (author)

  8. SU-G-TeP3-05: In Vitro Demonstration of Endothelial Dose Enhancement Due to Gold Nanoparticles During Low-Voltage Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yasmin-Karim, S; Makrigiorgos, GM [Brigham and Women’s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, MA (United States); Moreau, M; Ngwa, W [Brigham and Women’s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, MA (United States); University of Massachusetts Lowell, Lowell, MA (United States); Kumar, R [Brigham and Women’s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, MA (United States); Northeastern University, Boston, MA (United States); Hanlon, J; Arnoldussen, M [Oraya Therapeutics Inc., Newark, CA (United States); Hempstead, J; Celli, J [University of Massachusetts Boston, Boston, MA (United States)

    2016-06-15

    Purpose: Oraya Therapy uses low-voltage, stereotactic, highly targeted X-rays for the treatment of wet age-related macular degeneration (AMD) — offering a new option for patients worldwide. Neovascular endothelial cells play a crucial role in the pathogenesis of this disease. This in-vitro study investigates the potential of gold nanoparticles (GNP) to enhance endothelial cell damage during low-voltage radiotherapy towards potential applications in the treatment of wet-AMD. Methods: Primary human umbilical cord vein endothelium cells (HUVEC) were treated with 1.4 nm sized GNPs for 24 hrs and then irradiated with variable X-ray doses using an Oraya therapy system (100 kVp) or a Small Animal Radiation and Research platform (SARRP) at other beam qualities (up to 220 kVp). Radio-sensitization was assessed by clonogenic assays. Variable concentrations of GNPs (0.05 mg/ml, 0.1 mg/ml, 0.25 mg/ml, 0.5 mg/ml, and 1 mg/ml) where employed. The dose enhancement factor (DEF) was calculated as the ratio of radiation doses required to give the same biological effect (survival factor, SF) with and without GNPs. Results: Preliminary results show DEFs of up to 2.62 for the different combinations of x-ray doses and GNP concentrations and beam qualities. In general the DEF increased with increase in GNP concentration. However, for high doses the effect of GNP becomes less apparent likely due to already high cell kill by the radiation alone. Conclusion: The findings suggest that targeted GNPs can play a significant synergistic role in enhancing stereotactic radiosurgery for wet AMD. The results also provide impetus for ongoing studies to find the optimal synergy between the doses or beam energies and GNPs concentration. This will benefit in-vivo studies towards development of nanoparticle-aided radiotherapy for treatment of wet-AMD and potentially ocular cancers.

  9. Efficacy of Low-Dose Protocol in Follow-Up of Lymphoproliferative Disorders - Preliminary Results

    International Nuclear Information System (INIS)

    Popic-Ramac, J.; Brnic, Z.; Klasic, B.; Hebrang, A.; Knezevic, Z.

    2011-01-01

    Most medically-related radiation is caused by diagnostic examinations, in particular by computed tomography (CT). The purpose of this research is to reduce radiation doses faced by the population frequently exposed to such procedures-those with lymphoproliferative disorders. The research was conducted comparing radiation-exposition doses received by the radiosensitive organs (thyroid, lens, breast and gonad) using the standard thoracic CT protocol with the radiation received using the low-dose protocol, while maintaining display quality. The standard-dose thoracic protocol implies 120 kV and 150 mAs. The low-dose protocol was conducted on the same device using 120 kV and 30 mAs. We confirmed the hypothesis that the use of the low-dose thoracic CT protocol leads to a reduction in radiation dose without compromising display quality. It is further expected that a reduction in doses will reduce the risk of radiation-related mutations. (author)

  10. Vivo dosimetry using TLD detectors in prostate seed implants of I-125: preliminary results

    International Nuclear Information System (INIS)

    Sanchez-Reyes, A.; Pedro, A.; Bassas, P.; Duch, M. A.; Cros, M.; Mane, S.

    2011-01-01

    We present preliminary results of a new in vivo dosimetry technique that could allow to know immediately after implantation of the prostate if the dose distribution determined by the scheduler is similar to the actual dose measured with TLD detectors.

  11. Lung function in adults following in utero and childhood exposure to arsenic in drinking water: preliminary findings.

    Science.gov (United States)

    Dauphiné, David C; Ferreccio, Catterina; Guntur, Sandeep; Yuan, Yan; Hammond, S Katharine; Balmes, John; Smith, Allan H; Steinmaus, Craig

    2011-08-01

    Evidence suggests that arsenic in drinking water causes non-malignant lung disease, but nearly all data concern exposed adults. The desert city of Antofagasta (population 257,976) in northern Chile had high concentrations of arsenic in drinking water (>800 μg/l) from 1958 until 1970, when a new treatment plant was installed. This scenario, with its large population, distinct period of high exposure, and accurate data on past exposure, is virtually unprecedented in environmental epidemiology. We conducted a pilot study on early-life arsenic exposure and long-term lung function. We present these preliminary findings because of the magnitude of the effects observed. We recruited a convenience sample consisting primarily of nursing school employees in Antofagasta and Arica, a city with low drinking water arsenic. Lung function and respiratory symptoms in 32 adults exposed to >800 μg/l arsenic before age 10 were compared to 65 adults without high early-life exposure. Early-life arsenic exposure was associated with 11.5% lower forced expiratory volume in 1 s (FEV(1)) (P = 0.04), 12.2% lower forced vital capacity (FVC) (P = 0.04), and increased breathlessness (prevalence odds ratio = 5.94, 95% confidence interval 1.36-26.0). Exposure-response relationships between early-life arsenic concentration and adult FEV(1) and FVC were also identified (P trend = 0.03). Early-life exposure to arsenic in drinking water may have irreversible respiratory effects of a magnitude similar to smoking throughout adulthood. Given the small study size and non-random recruitment methods, further research is needed to confirm these findings.

  12. Entyvio lengthen dose-interval study: lengthening vedolizumab dose interval and the risk of clinical relapse in inflammatory bowel disease.

    Science.gov (United States)

    Chan, Webber; Lynch, Nicole; Bampton, Peter; Chang, Jeff; Chung, Alvin; Florin, Timothy; Hetzel, David J; Jakobovits, Simon; Moore, Gregory; Pavli, Paul; Radford-Smith, Graham; Thin, Lena; Baraty, Brandon; Haifer, Craig; Yau, Yunki; Leong, Rupert W L

    2018-07-01

    Vedolizumab (VDZ), an α4β7 anti-integrin antibody, is efficacious in the induction and maintenance of remission in ulcerative colitis (UC) and Crohn's disease (CD). In the GEMINI long-term safety study, enrolled patients received 4-weekly VDZ. Upon completion, patients were switched to 8-weekly VDZ in Australia. The clinical success rate of treatment de-escalation for patients in remission on VDZ has not been described previously. To determine the proportion of patients who relapsed after switching from 4 to 8-weekly VDZ, the mean time to relapse, and the recapture rate when switching back to 8-weekly dosing. This was a retrospective, observational, multicenter study of patients previously recruited into GEMINI long-term safety in Australia. Data on the demographics and biochemical findings were collected. There were 34 patients [23 men, mean age 49.1 (±13.1) years] and their mean disease duration was 17.6 (±8.5) years. The mean 4-weekly VDZ infusion duration was 286.5 (±48.8) weeks. A total of five (15%) patients relapsed on dose-interval increase (4/17 UC, 1/17 CD) at a median duration from dose interval lengthening to flare of 14 weeks (interquartile range=6-25). Eighty percent (4/5) of patients re-entered remission following dose-interval decrease back to 4-weekly. No clinical predictors of relapse could be determined because of the small cohort size. The risk of patients relapsing when switching from 4 to 8-weekly VDZ ∼15% and is similar between CD and UC. Dose-interval decrease recaptures 80% of patients who relapsed. Therapeutic drug monitoring of VDZ may be of clinical relevance.

  13. Evidence for single-dose protection by the bivalent HPV vaccine-Review of the Costa Rica HPV vaccine trial and future research studies.

    Science.gov (United States)

    Kreimer, Aimée R; Herrero, Rolando; Sampson, Joshua N; Porras, Carolina; Lowy, Douglas R; Schiller, John T; Schiffman, Mark; Rodriguez, Ana Cecilia; Chanock, Stephen; Jimenez, Silvia; Schussler, John; Gail, Mitchell H; Safaeian, Mahboobeh; Kemp, Troy J; Cortes, Bernal; Pinto, Ligia A; Hildesheim, Allan; Gonzalez, Paula

    2018-01-20

    The Costa Rica Vaccine Trial (CVT), a phase III randomized clinical trial, provided the initial data that one dose of the HPV vaccine could provide durable protection against HPV infection. Although the study design was to administer all participants three doses of HPV or control vaccine, 20% of women did not receive the three-dose regimens, mostly due to involuntary reasons unrelated to vaccination. In 2011, we reported that a single dose of the bivalent HPV vaccine could be as efficacious as three doses of the vaccine using the endpoint of persistent HPV infection accumulated over the first four years of the trial; findings independently confirmed in the GSK-sponsored PATRICIA trial. Antibody levels after one dose, although lower than levels elicited by three doses, were 9-times higher than levels elicited by natural infection. Importantly, levels remained essentially constant over at least seven years, suggesting that the observed protection provided by a single dose might be durable. Much work has been done to assure these non-randomized findings are valid. Yet, the group of recipients who received one dose of the bivalent HPV vaccine in the CVT and PATRICIA trials was small and not randomly selected nor blinded to the number of doses received. The next phase of research is to conduct a formal randomized, controlled trial to evaluate the protection afforded by a single dose of HPV vaccine. Complementary studies are in progress to bridge our findings to other populations, and to further document the long-term durability of antibody response following a single dose. Published by Elsevier Ltd.

  14. Preliminary design study of a steady state tokamak device

    International Nuclear Information System (INIS)

    Miya, Naoyuki; Nakajima, Shinji; Ushigusa, Kenkichi; and athors)

    1992-09-01

    Preliminary design study has been made for a steady tokamak with the plasma current of 10MA, as the next to the JT-60U experimental programs. The goal of the research program is the integrated study of steady state, high-power physics and technology. Present candidate design is to use superconducting TF and PF magnet systems and long pulse operation of 100's-1000's of sec with non inductive current drive mainly by 500keV negative ion beam injection of 60MW. Low activation material such as titanium alloy is chosen for the water tank type vacuum vessel, which is also the nuclear shield for the superconducting coils. The present preliminary design study shows that the device can meet the existing JT-60U facility capability. (author)

  15. Preliminary studies to determine the shelf life of HEPA filters

    Energy Technology Data Exchange (ETDEWEB)

    Gilbert, H.; Fretthold, J.K.; Rainer, F. [Lawrence Livermore National Laboratory, CA (United States)] [and others

    1995-02-01

    We have completed a preliminary study using filter media tests and filter qualification tests to investigate the effect of shelf-life on HEPA filter performance. Our media studies showed that the tensile strength decreased with age, but the data were not sufficient to establish a shelf-life. Thermogravimetric analyses demonstrated that one manufacturer had media with low tensile strength due to insufficient binder. The filter qualification tests (heated air and overpressure) conducted on different aged filters showed that filter age is not the primary factor affecting filter performance; materials and the construction design have a greater effect. An unexpected finding of our study was that sub-standard HEPA filters have been installed in DOE facilities despite existing regulations and filter qualification tests. We found that the filter with low tensile strength failed the overpressure test. The same filter had passed the heated air test, but left the filter so structurally weak, it was prone to blow-out. We recommend that DOE initiate a filter qualification program to prevent this occurrence.

  16. Lateral topography for reducing effective dose in low-dose chest CT.

    Science.gov (United States)

    Bang, Dong-Ho; Lim, Daekeon; Hwang, Wi-Sub; Park, Seong-Hoon; Jeong, Ok-man; Kang, Kyung Wook; Kang, Hohyung

    2013-06-01

    The purposes of this study were to assess radiation exposure during low-dose chest CT by using lateral topography and to compare the lateral topographic findings with findings obtained with anteroposterior topography alone and anteroposterior and lateral topography combined. From November 2011 to February 2012, 210 male subjects were enrolled in the study. Age, weight, and height of the men were recorded. All subjects were placed into one of three subgroups based on the type of topographic image obtained: anteroposterior topography, lateral topography, and both anteroposterior and lateral topography. Imaging was performed with a 128-MDCT scanner. CT, except for topography, was the same for all subjects. A radiologist analyzed each image, recorded scan length, checked for any insufficiencies in the FOV, and calculated the effective radiation dose. One-way analysis of variance and multiple comparisons were used to compare the effective radiation exposure and scan length between groups. The mean scan length in the anteroposterior topography group was significantly greater than that of the lateral topography group and the combined anteroposterior and lateral topography group (p topography group (0.735 ± 0.033 mSv) was significantly lower than that for the anteroposterior topography group (0.763 ± 0.038 mSv) and the combined anteroposterior and lateral topography group (0.773 ± 0.038) (p < 0.001). Lateral topographic low-dose CT was associated with a lower effective radiation dose and scan length than either anteroposterior topographic low-dose chest CT or low-dose chest CT with both anteroposterior and lateral topograms.

  17. Smoking topography in Korean American and white men: preliminary findings.

    Science.gov (United States)

    Chung, Sangkeun; Kim, Sun S; Kini, Nisha; Fang, Hua J; Kalman, David; Ziedonis, Douglas M

    2015-06-01

    This is the first study of Korean Americans' smoking behavior using a topography device. Korean American men smoke at higher rates than the general U.S. Korean American and White men were compared based on standard tobacco assessment and smoking topography measures. They smoked their preferred brand of cigarettes ad libitum with a portable smoking topography device for 24 h. Compared to White men (N = 26), Korean American men (N = 27) were more likely to smoke low nicotine-yield cigarettes (p Whites. Controlling for the number of cigarettes smoked, Koreans smoked with higher average puff flows (p = 0.05), greater peak puff flows (p = 0.02), and shorter interpuff intervals (p Whites. Puff counts, puff volumes, and puff durations did not differ between the two groups. This study offers preliminary insight into unique smoking patterns among Korean American men who are likely to smoke low nicotine-yield cigarettes. We found that Korean American men compensated their lower number and low nicotine-yield cigarettes by smoking with greater puff flows and shorter interpuff intervals than White men, which may suggest exposures to similar amounts of nicotine and harmful tobacco toxins by both groups. Clinicians will need to consider in identifying and treating smokers in a mutually aggressive manner, irrespective of cigarette type and number of cigarette smoked per day.

  18. Influence of dose, age at the onset of disease and ultrasonographic findings of the thyroid gland on the early outcome of the radioiodine treatment of hyperthyroidism

    International Nuclear Information System (INIS)

    Ugrinska, A.; Pop Gjorceva, D.; Muratovska, L.; Crcareva, B.; Stojanovski, S.

    2007-01-01

    Full text: Aim of the study: Estimation of the early effects of the treatment of hyperthyroidism with radioactive iodine in correlation with the radioiodine dose, the age at the onset of disease and ultrasonographic (US) findings of the thyroid. Material and methods: Retrospective analysis of the files of 80 patients that underwent a radioactive iodine treatment from the period of 1987 till 2006 because of a diffuse hyperthyroid goiter was performed. The patients were divided in two groups. Group C consisted of patients who were treated with calculated doses from 60-100μC/ml gland volume and group NC who received higher, non-calculated doses. According to age at the onset of disease patients were divided in two groups- group A younger than 40 years and group B older than 40 years. According to the US findings of the thyroid prior to radioiodine therapy patients were divided in two groups group N with predominantly normal US findings and group H with predominantly hypoechoic structure. Results: One year after the application of radioactive iodine 58% of the patients from the group C still remained hyperthyroid, 29% became euthyroid and only 13% developed early hypothyroidism. In the NC group only 7% remained hyperthyroid, 40% were euthyroid, while 54% of the patients developed early hypothyroidism. The occurrence of early hypothyroidism was significantly more frequent in NC than in C group (58% vs. 32%, p<0.05). The age was predictor for the probability of development of early hypothyroidism in C group: only 13% younger in group A, but 46% older patients from group B developed an early hypothyroidism. In the NC group the age was not a predictive factor. In 44 patients there were available records on the US findings prior to radioiodine therapy. In the N group patients that received calculated dose of radioiodine therapy remained euthyroid in 86%, while the patients that received non-calculated dose achieved euthyroidism only in 30%.In the H group there was no

  19. Assessing health-related resiliency in HIV+ Latin women: Preliminary psychometric findings.

    Directory of Open Access Journals (Sweden)

    Gladys J Jimenez-Torres

    Full Text Available HIV-associated vulnerabilities-especially those linked to psychological issues-and limited mental health-treatment resources have the potential to adversely affect the health statuses of individuals. The concept of resilience has been introduced in the literature to shift the emphasis from vulnerability to protective factors. Resilience, however, is an evolving construct and is measured in various ways, though rarely among underserved, minority populations. Herein, we present the preliminary psychometric properties of a sample of HIV-seropositive Puerto Rican women, measured using a newly developed health-related resilience scale.The Resilience Scales for Children and Adolescents, an instrument with solid test construction properties, acted as a model in the development (in both English and Spanish of the HRRS, providing the same dimensions and most of the same subscales. The present sample was nested within the Hispanic-Latino longitudinal cohort of women (HLLC, that is part of the NeuroAIDS Research Program at the University of Puerto Rico (UPR, Medical Sciences Campus (MSC. Forty-five consecutively recruited, HIV+ women from the HLLC completed a demographic survey, the HRRS, and the Beck Depression Inventory-I, Spanish version.The results demonstrate excellent overall internal consistency for the total HRRS score (α = 0.95. Each of the dimensional scores also evidenced acceptable internal consistency (α ≥ 0.88. All the dimensional and subscale content validity indices were above the 0.42 cut-off. Analysis revealed a significant negative correlation between the HRRS total score and BDI-I-S (r(45 = -0.453, p < 0.003.Albeit preliminary in nature, the present study provides support for the HRRS as a measure to assess resilience among individuals living with chronic medical conditions. Minority populations, especially non-English speaking ones, are understudied across the field of medicine, and when efforts are made to include these patient

  20. The continual reassessment method: comparison of Bayesian stopping rules for dose-ranging studies.

    Science.gov (United States)

    Zohar, S; Chevret, S

    2001-10-15

    The continual reassessment method (CRM) provides a Bayesian estimation of the maximum tolerated dose (MTD) in phase I clinical trials and is also used to estimate the minimal efficacy dose (MED) in phase II clinical trials. In this paper we propose Bayesian stopping rules for the CRM, based on either posterior or predictive probability distributions that can be applied sequentially during the trial. These rules aim at early detection of either the mis-choice of dose range or a prefixed gain in the point estimate or accuracy of estimated probability of response associated with the MTD (or MED). They were compared through a simulation study under six situations that could represent the underlying unknown dose-response (either toxicity or failure) relationship, in terms of sample size, probability of correct selection and bias of the response probability associated to the MTD (or MED). Our results show that the stopping rules act correctly, with early stopping by using the two first rules based on the posterior distribution when the actual underlying dose-response relationship is far from that initially supposed, while the rules based on predictive gain functions provide a discontinuation of inclusions whatever the actual dose-response curve after 20 patients on average, that is, depending mostly on the accumulated data. The stopping rules were then applied to a data set from a dose-ranging phase II clinical trial aiming at estimating the MED dose of midazolam in the sedation of infants during cardiac catheterization. All these findings suggest the early use of the two first rules to detect a mis-choice of dose range, while they confirm the requirement of including at least 20 patients at the same dose to reach an accurate estimate of MTD (MED). A two-stage design is under study. Copyright 2001 John Wiley & Sons, Ltd.

  1. Fully automated treatment planning for head and neck radiotherapy using a voxel-based dose prediction and dose mimicking method

    Science.gov (United States)

    McIntosh, Chris; Welch, Mattea; McNiven, Andrea; Jaffray, David A.; Purdie, Thomas G.

    2017-08-01

    Recent works in automated radiotherapy treatment planning have used machine learning based on historical treatment plans to infer the spatial dose distribution for a novel patient directly from the planning image. We present a probabilistic, atlas-based approach which predicts the dose for novel patients using a set of automatically selected most similar patients (atlases). The output is a spatial dose objective, which specifies the desired dose-per-voxel, and therefore replaces the need to specify and tune dose-volume objectives. Voxel-based dose mimicking optimization then converts the predicted dose distribution to a complete treatment plan with dose calculation using a collapsed cone convolution dose engine. In this study, we investigated automated planning for right-sided oropharaynx head and neck patients treated with IMRT and VMAT. We compare four versions of our dose prediction pipeline using a database of 54 training and 12 independent testing patients by evaluating 14 clinical dose evaluation criteria. Our preliminary results are promising and demonstrate that automated methods can generate comparable dose distributions to clinical. Overall, automated plans achieved an average of 0.6% higher dose for target coverage evaluation criteria, and 2.4% lower dose at the organs at risk criteria levels evaluated compared with clinical. There was no statistically significant difference detected in high-dose conformity between automated and clinical plans as measured by the conformation number. Automated plans achieved nine more unique criteria than clinical across the 12 patients tested and automated plans scored a significantly higher dose at the evaluation limit for two high-risk target coverage criteria and a significantly lower dose in one critical organ maximum dose. The novel dose prediction method with dose mimicking can generate complete treatment plans in 12-13 min without user interaction. It is a promising approach for fully automated treatment

  2. Neuromuscular dose-response studies: determining sample size.

    Science.gov (United States)

    Kopman, A F; Lien, C A; Naguib, M

    2011-02-01

    Investigators planning dose-response studies of neuromuscular blockers have rarely used a priori power analysis to determine the minimal sample size their protocols require. Institutional Review Boards and peer-reviewed journals now generally ask for this information. This study outlines a proposed method for meeting these requirements. The slopes of the dose-response relationships of eight neuromuscular blocking agents were determined using regression analysis. These values were substituted for γ in the Hill equation. When this is done, the coefficient of variation (COV) around the mean value of the ED₅₀ for each drug is easily calculated. Using these values, we performed an a priori one-sample two-tailed t-test of the means to determine the required sample size when the allowable error in the ED₅₀ was varied from ±10-20%. The COV averaged 22% (range 15-27%). We used a COV value of 25% in determining the sample size. If the allowable error in finding the mean ED₅₀ is ±15%, a sample size of 24 is needed to achieve a power of 80%. Increasing 'accuracy' beyond this point requires increasing greater sample sizes (e.g. an 'n' of 37 for a ±12% error). On the basis of the results of this retrospective analysis, a total sample size of not less than 24 subjects should be adequate for determining a neuromuscular blocking drug's clinical potency with a reasonable degree of assurance.

  3. An open pilot study of zonisamide augmentation in major depressive patients not responding to a low dose trial with duloxetine: preliminary results on tolerability and clinical effects

    Directory of Open Access Journals (Sweden)

    Benvenuti Marzia

    2011-09-01

    Full Text Available Abstract Background Despite multiple antidepressant options, major depressive disorder (MDD still faces high non-response rates, eventually requiring anticonvulsant augmentation strategies too. The aim of this study was to explore such a potential role for zonisamide. Methods A total of 40 MDD outpatients diagnosed using the Diagnostic and Statistical Manual for Mental Disorders, fourth edition criteria entered a 24 week open trial receiving duloxetine 60 mg/day for the first 12 weeks and subsequently (weeks 12 to 24 augmentation with zonisamide 75 mg/day if they did not respond to the initial monotherapy. Efficacy and tolerability were assessed using the Hamilton Scales for Anxiety and Depression (a 12 week score ≥50% vs baseline defined 'non-response', the Arizona Sexual Experience Scale, the Patient Rated Inventory of Side Effects and the Young Mania Rating Scale. Results At week 12, 15 patients out of 39 (38.5% were responders, and 1 had dropped out; remarkably, 14 patients out of 24 (58.3% had achieved response by week 24. Poor concentration and general malaise were associated with non-response both at week 12 and 24 (P = 0.001, while loss of libido and reduced energy were prominent among final timepoint non-responders. Patients receiving zonisamide also experienced weight reduction (2.09 ± 12.14 kg; P = 0.001 independently of the outcome. Conclusions Although only a preliminary study due to strong methodological limitations, and thus requiring confirmation by further controlled investigations, the current results indicate zonisamide may be a potential augmentation option for some depressed patients receiving low doses of duloxetine.

  4. First Italian intercomparison on methodologies for dose assessment from internal contamination. Results and perspectives

    International Nuclear Information System (INIS)

    Castellani, C.M.; Battisti, P.; Tarroni, G.

    1998-01-01

    In the frame of the MIDIA activities (coordination of whole body counters operating in Italy) an intercomparison on dose evaluation methods was promoted and carried out between October 1995 and March 1996 by 5 WBC centres. The main results related to the estimation of Intake and effective dose equivalent on the four case studies are reported. A comparison with European preliminary results is also presented. Finally perspectives related to the quality assurance of internal dosimetry estimates are indicated [it

  5. Can typical US home visits affect infant attachment? Preliminary findings from a randomized trial of Healthy Families Durham.

    Science.gov (United States)

    Berlin, Lisa J; Martoccio, Tiffany L; Appleyard Carmody, Karen; Goodman, W Benjamin; O'Donnell, Karen; Williams, Janis; Murphy, Robert A; Dodge, Kenneth A

    2017-12-01

    US government-funded early home visiting services are expanding significantly. The most widely implemented home visiting models target at-risk new mothers and their infants. Such home visiting programs typically aim to support infant-parent relationships; yet, such programs' effects on infant attachment quality per se are as yet untested. Given these programs' aims, and the crucial role of early attachments in human development, it is important to understand attachment processes in home visited families. The current, preliminary study examined 94 high-risk mother-infant dyads participating in a randomized evaluation of the Healthy Families Durham (HFD) home visiting program. We tested (a) infant attachment security and disorganization as predictors of toddler behavior problems and (b) program effects on attachment security and disorganization. We found that (a) infant attachment disorganization (but not security) predicted toddler behavior problems and (b) participation in HFD did not significantly affect infant attachment security or disorganization. Findings are discussed in terms of the potential for attachment-specific interventions to enhance the typical array of home visiting services.

  6. Testing a Preliminary Live with Love Conceptual Framework for cancer couple dyads: A mixed-methods study.

    Science.gov (United States)

    Li, Qiuping; Xu, Yinghua; Zhou, Huiya; Loke, Alice Yuen

    2015-12-01

    The purpose of this study was to test the previous proposed Preliminary Live with Love Conceptual Framework (P-LLCF) that focuses on spousal caregiver-patient couples in their journey of coping with cancer as dyads. A mixed-methods study that included qualitative and quantitative approaches was conducted. Methods of concept and theory analysis, and structural equation modeling (SEM) were applied in testing the P-LLCF. In the qualitative approach in testing the concepts included in the P-LLCF, a comparison was made between the P-LLCF with a preliminary conceptual framework derived from focus group interviews among Chinese couples' coping with cancer. The comparison showed that the concepts identified in the P-LLCF are relevant to the phenomenon under scrutiny, and attributes of the concepts are consistent with those identified among Chinese cancer couple dyads. In the quantitative study, 117 cancer couples were recruited. The findings showed that inter-relationships exist among the components included in the P-LLCF: event situation, dyadic mediators, dyadic appraisal, dyadic coping, and dyadic outcomes. In that the event situation will impact the dyadic outcomes directly or indirectly through Dyadic Mediators. The dyadic mediators, dyadic appraisal, and dyadic coping are interrelated and work together to benefit the dyadic outcomes. This study provides evidence that supports the interlinked components and the relationship included in the P-LLCF. The findings of this study are important in that they provide healthcare professionals with guidance and directions according to the P-LLCF on how to plan supportive programs for couples coping with cancer. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Dose-to-medium vs. dose-to-water: Dosimetric evaluation of dose reporting modes in Acuros XB for prostate, lung and breast cancer

    Directory of Open Access Journals (Sweden)

    Suresh Rana

    2014-12-01

    Full Text Available Purpose: Acuros XB (AXB dose calculation algorithm is available for external beam photon dose calculations in Eclipse treatment planning system (TPS. The AXB can report the absorbed dose in two modes: dose-to-water (Dw and dose-to-medium (Dm. The main purpose of this study was to compare the dosimetric results of the AXB_Dm with that of AXB_Dw on real patient treatment plans. Methods: Four groups of patients (prostate cancer, stereotactic body radiation therapy (SBRT lung cancer, left breast cancer, and right breast cancer were selected for this study, and each group consisted of 5 cases. The treatment plans of all cases were generated in the Eclipse TPS. For each case, treatment plans were computed using AXB_Dw and AXB_Dm for identical beam arrangements. Dosimetric evaluation was done by comparing various dosimetric parameters in the AXB_Dw plans with that of AXB_Dm plans for the corresponding patient case. Results: For the prostate cancer, the mean planning target volume (PTV dose in the AXB_Dw plans was higher by up to 1.0%, but the mean PTV dose was within ±0.3% for the SBRT lung cancer. The analysis of organs at risk (OAR results in the prostate cancer showed that AXB_Dw plans consistently produced higher values for the bladder and femoral heads but not for the rectum. In the case of SBRT lung cancer, a clear trend was seen for the heart mean dose and spinal cord maximum dose, with AXB_Dw plans producing higher values than the AXB_Dm plans. However, the difference in the lung doses between the AXB_Dm and AXB_Dw plans did not always produce a clear trend, with difference ranged from -1.4% to 2.9%. For both the left and right breast cancer, the AXB_Dm plans produced higher maximum dose to the PTV for all cases. The evaluation of the maximum dose to the skin showed higher values in the AXB_Dm plans for all 5 left breast cancer cases, whereas only 2 cases had higher maximum dose to the skin in the AXB_Dm plans for the right breast cancer

  8. A Study on the Single-dose Oral Toxicity of Super Key in Sprague-Dawley Rats

    Directory of Open Access Journals (Sweden)

    Jinhee Kim

    2015-09-01

    Full Text Available Objectives: This study was performed to analyze the single-dose oral toxicity of the super key (processed sulfur. Methods: All experiments were conducted at Medvill, an institution authorized to perform non-clinical studies, under the Good Laboratory Practice (GLP regulations. In order to investigate the oral toxicity of super key We administered it orally to Sprague-Dawley (SD rats. The SD rats were divided into four groups of five male and five female animals per group: group 1 being the control group and groups 2, 3, and 4 being the experimental groups. Doses of super key 500 mg/kg, 1,000 mg/kg and 2,000 mg/kg were administered to the experimental groups, and a dose of normal saline solution, 10 mL/kg, was administered to the control group. We examined the survival rates, weights, clinical signs, gross findings and necropsy findings. This study was conducted under the approval of the Institutional Animal Ethics Committee. (Approval number: A01-14018. Results: No deaths or abnormalities occurred in any of the four groups. Although slight decreases in the weights of some female rats were noted, no significant changes in weights or differences in the gross findings between the control group and the experimental groups were observed. To check for abnormalities in organs, we used microscopy to examine representative histological sections of each specified organ; the results showed no significant differences in any of the organs. Conclusion: The results of this research showed that administration of 500 ─ 2,000 mg/kg of super key did not cause any changes in the weights or in the results of necropsy examinations. Neither did it result in any mortalities. The above findings suggest that treatment with super key is relatively safe. Further studies on this subject are needed to yield more concrete evidence.

  9. Preliminary risk assessments of the small HTGR

    International Nuclear Information System (INIS)

    Everline, C.J.; Bellis, E.A.

    1985-05-01

    Preliminary investment and safety risk assessments were performed for a preconceptual design of a four-module 250-MW(t) side-by-side steel-vessel pebble bed HTGR plant. Broad event spectra were analyzed involving component damage resulting in unscheduled plant outages and fission product releases resulting in offsite doses. The preliminary assessment indicates at this stage of the design that two categories of events govern the investment risk envelope: primary coolant leaks which release some circulating and plate-out activity that contaminates the confinement and turbogenerator damage which involves extensive turbine blade failure. Primary coolant leaks are important contributors because associated cleanup and decontamination requirements result in longer outages that arise from other events with comparable frequencies. Turbogenerator damage is the salient low-frequency investment risk accident due to the relatively long outages being experienced in the industry. Thermal transients are unimportant investment risk contributors because pressurized core heatups cause little damage, and depressurized core heatups occur at negligible frequencies relative to the forced outage goal. These preliminary results demonstrate investment and safety risk goal compliance at this stage in the design process. Studies are continuing in order to provide valuable insights into risk-significant events to assure a balanced approach to meeting user and regulatory requirements

  10. Dose-response relationship in the treatment of gastrointestinal disorders.

    Science.gov (United States)

    Weihrauch, T R; Demol, P

    1989-08-01

    Numerous clinical studies have been performed to establish efficacy and safety of drugs in gastroenterological disorders. Only in a few if any of these studies, however, the rationale for the optimal dose and the dose regimens, respectively, have been addressed. Adequate and well-controlled dose finding studies play a key role in the clinical assessment of new drugs and in the evaluation of new indications. Hereby the range from the minimal effective dose to the maximal effective and well tolerated dose can be assessed and thus the optimal dose-range and dosage regimen be determined. Meaningful pharmacodynamic studies can be performed in the gastrointestinal tract also in healthy volunteers provided that a method with a high predictability for the desired therapeutic effect is available such as measurement of gastric acid secretion and its inhibition by a drug. Dose finding studies in gastroenterology can be carried out under two main aspects: First, to assess the pharmacodynamic and therapeutic effect of a compound on the gastrointestinal tract (e.g. anti-ulcer drug). Second, to evaluate the side effects of a drug on the gastrointestinal tract (e.g. gastric mucosal damage by non-steroidal anti-inflammatory drugs). For the evaluation of new drugs in gastrointestinal therapy a number of methods are available which yield accurate and reproducible data. While careful clinical-pharmacological dose-response studies using these methods have been carried out already more than a decade ago, it is surprising that therapeutic dose finding studies have become available only during the past few years. For scientific as well as for ethical reasons more trials which determine the optimal therapeutic dose are warranted.

  11. A phase I open-label dose-escalation study of the anti-HER3 monoclonal antibody LJM716 in patients with advanced squamous cell carcinoma of the esophagus or head and neck and HER2-overexpressing breast or gastric cancer.

    Science.gov (United States)

    Reynolds, Kerry Lynn; Bedard, Philippe L; Lee, Se-Hoon; Lin, Chia-Chi; Tabernero, Josep; Alsina, Maria; Cohen, Ezra; Baselga, José; Blumenschein, George; Graham, Donna M; Garrido-Laguna, Ignacio; Juric, Dejan; Sharma, Sunil; Salgia, Ravi; Seroutou, Abdelkader; Tian, Xianbin; Fernandez, Rose; Morozov, Alex; Sheng, Qing; Ramkumar, Thiruvamoor; Zubel, Angela; Bang, Yung-Jue

    2017-09-12

    Human epidermal growth factor receptor 3 (HER3) is important in maintaining epidermal growth factor receptor-driven cancers and mediating resistance to targeted therapy. A phase I study of anti-HER3 monoclonal antibody LJM716 was conducted with the primary objective to identify the maximum tolerated dose (MTD) and/or recommended dose for expansion (RDE), and dosing schedule. Secondary objectives were to characterize safety/tolerability, pharmacokinetics, pharmacodynamics, and preliminary antitumor activity. This open-label, dose-finding study comprised dose escalation, followed by expansion in patients with squamous cell carcinoma of the head and neck or esophagus, and HER2-overexpressing metastatic breast cancer or gastric cancer. During dose escalation, patients received LJM716 intravenous once weekly (QW) or every two weeks (Q2W), in 28-day cycles. An adaptive Bayesian logistic regression model was used to guide dose escalation and establish the RDE. Exploratory pharmacodynamic tumor studies evaluated modulation of HER3 signaling. Patients received LJM716 3-40 mg/kg QW and 20 mg/kg Q2W (54 patients; 36 patients at 40 mg/kg QW). No dose-limiting toxicities (DLTs) were reported during dose-escalation. One patient experienced two DLTs (diarrhea, hypokalemia [both grade 3]) in the expansion phase. The RDE was 40 mg/kg QW, providing drug levels above the preclinical minimum effective concentration. One patient with gastric cancer had an unconfirmed partial response; 17/54 patients had stable disease, two lasting >30 weeks. Down-modulation of phospho-HER3 was observed in paired tumor samples. LJM716 was well tolerated; the MTD was not reached, and the RDE was 40 mg/kg QW. Further development of LJM716 is ongoing. Clinicaltrials.gov registry number NCT01598077 (registered on 4 May, 2012).

  12. Development of an X-ray installation for the study of secondary electrons: preliminary measurements and calculations

    International Nuclear Information System (INIS)

    Baguena, A.; Shaw, M.; Williart, A.; Baguena, A.; Garcia, G.

    2006-01-01

    We describe the calculations and preliminary measures made for the installation of a X-ray generator tube. This device is going to be used for the secondary electron production from photonic primary radiation of up to 125 keV. With this experimental system, we will study the energetic and space distribution of produced secondary electrons by obtaining its spectrum of energies and its angular distribution. This method of measurement is going to be applied in different targets of radiological, environmental and biological interest. Calculations in the present article include: theoretical yield of X-rays production of the designed equipment, necessary shielding for the radiological safety of the installation staff, and an estimated dose due to their use. Characteristics of the installation and the equipment are described with this purpose. (author)

  13. Development of an X-ray installation for the study of secondary electrons: preliminary measurements and calculations

    Energy Technology Data Exchange (ETDEWEB)

    Baguena, A.; Shaw, M.; Williart, A. [Universidad Nacional de Educacion a Distancia, Dpto. Fisica de los Materiales, Madrid (Spain); Baguena, A. [Consejo de Seguridad Nuclear, Madrid (Spain); Garcia, G. [Instituto de Matematicas y Fisica Fundamental, Consejo Superior de Investigaciones Cientificas, Madrid (Spain)

    2006-07-01

    We describe the calculations and preliminary measures made for the installation of a X-ray generator tube. This device is going to be used for the secondary electron production from photonic primary radiation of up to 125 keV. With this experimental system, we will study the energetic and space distribution of produced secondary electrons by obtaining its spectrum of energies and its angular distribution. This method of measurement is going to be applied in different targets of radiological, environmental and biological interest. Calculations in the present article include: theoretical yield of X-rays production of the designed equipment, necessary shielding for the radiological safety of the installation staff, and an estimated dose due to their use. Characteristics of the installation and the equipment are described with this purpose. (author)

  14. First Italian intercomparison on methodologies for dose assessment from internal contamination. Results and perspectives; Primo interconfronto italiano sulle metodiche di valutazione di dose da contaminazione interna: risultati e prospettive

    Energy Technology Data Exchange (ETDEWEB)

    Castellani, C.M.; Battisti, P.; Tarroni [ENEA, Centro Ricerche Ezio Clementel, Bologna (Italy). Dipt. Ambiente

    1998-07-01

    In the frame of the MIDIA activities (coordination of whole body counters operating in Italy) an intercomparison on dose evaluation methods was promoted and carried out between October 1995 and March 1996 by 5 WBC centres. The main results related to the estimation of Intake and effective dose equivalent on the four case studies are reported. A comparison with European preliminary results is also presented. Finally perspectives related to the quality assurance of internal dosimetry estimates are indicated. [Italian] Vengono riportati i risultati delle valutazioni di Intake e di equivalente di dose nei centri MIDIA (coordinamento dei WBC operanti in Italia) per effettuare un interconfronto sui metodi di valutazione di dose da contaminazione interna utilizzando casi di studio reperiti in ambiente europeo. Vengono indicate le prospettive per la valutazione della qualita' della stima di dose in dosimetria interna.

  15. Licensing support system preliminary needs analysis: Volume 1

    International Nuclear Information System (INIS)

    1989-01-01

    This Preliminary Needs Analysis, together with the Preliminary Data Scope Analysis (next in this series of reports), is a first effort under the LSS Design and Implementation Contract toward developing a sound requirements foundation for subsequent design work. Further refinements must be made before requirements can be specified in sufficient detail to provide a basis for suitably specific system specifications. This preliminary analysis of the LSS requirements has been divided into a ''needs'' and a ''data scope'' portion only for project management and scheduling reasons. The Preliminary Data Scope Analysis will address all issues concerning the content and size of the LSS data base; providing the requirements basis for data acquisition, cataloging and storage sizing specifications. This report addresses all other requirements for the LSS. The LSS consists of both computer subsystems and non-computer archives. This study addresses only the computer subsystems, focusing on the Access Subsystems. After providing background on previous LSS-related work, this report summarizes the findings from previous examinations of needs and describes a number of other requirements that have an impact on the LSS. The results of interviews conducted for this report are then described and analyzed. The final section of the report brings all of the key findings together and describes how these needs analyses will continue to be refined and utilized in on-going design activities. 14 refs., 2 figs., 1 tab

  16. Radiochemical studies, pre-clinical investigation and preliminary clinical evaluation of "1"7"0Tm-EDTMP prepared using in-house freeze-dried EDTMP kit

    International Nuclear Information System (INIS)

    Das, Tapas; Shinto, Ajit; Kamaleshwaran, Koramadai K.; Sarma, Haladhar D.; Mohammed, Sahiralam Khan; Mitra, Arpit; Lad, Sangita; Rajan, M.G.R.; Banerjee, Sharmila

    2017-01-01

    The objective of the present work is to formulate "1"7"0Tm-EDTMP using an in-house freeze-dried EDTMP kit and evaluate its potential as a bone pain palliation agent. Patient dose of "1"7"0Tm-EDTMP was prepared with high radiochemical purity using the lyophilized kit at room temperature within 15 min. Pre-clinical evaluation in normal Wistar rats revealed selective skeletal accumulation with extended retention. Preliminary clinical investigation in 8 patients with disseminated skeletal metastases exhibited selective uptake in the bone and retention therein for a long duration. - Highlights: • Formulation of patient dose of "1"7"0Tm-EDTMP using freeze-dried EDTMP kit. • Radiochemical studies and pre-clinical evaluation of the agent in animal model. • Clinical evaluation in eight cancer patients with disseminated skeletal metastases.

  17. Lymphoid cell kinetics under continuous low dose-rate gamma irradiation: A comparison study

    Science.gov (United States)

    Foster, B. R.

    1975-01-01

    A comparison study was conducted of the effects of continuous low dose-rate gamma irradiation on cell population kinetics of lymphoid tissue (white pulp) of the mouse spleen with findings as they relate to the mouse thymus. Experimental techniques employed included autoradiography and specific labeling with tritiated thymidine (TdR-(h-3)). The problem studied involved the mechanism of cell proliferation of lymphoid tissue of the mouse spleen and thymus under the stress of continuous irradiation at a dose rate of 10 roentgens (R) per day for 105 days (15 weeks). The aim was to determine whether or not a steady state or near-steady state of cell population could be established for this period of time, and what compensatory mechanisms of cell population were involved.

  18. Non-clinical studies in the process of new drug development - Part II: Good laboratory practice, metabolism, pharmacokinetics, safety and dose translation to clinical studies.

    Science.gov (United States)

    Andrade, E L; Bento, A F; Cavalli, J; Oliveira, S K; Schwanke, R C; Siqueira, J M; Freitas, C S; Marcon, R; Calixto, J B

    2016-12-12

    The process of drug development involves non-clinical and clinical studies. Non-clinical studies are conducted using different protocols including animal studies, which mostly follow the Good Laboratory Practice (GLP) regulations. During the early pre-clinical development process, also known as Go/No-Go decision, a drug candidate needs to pass through several steps, such as determination of drug availability (studies on pharmacokinetics), absorption, distribution, metabolism and elimination (ADME) and preliminary studies that aim to investigate the candidate safety including genotoxicity, mutagenicity, safety pharmacology and general toxicology. These preliminary studies generally do not need to comply with GLP regulations. These studies aim at investigating the drug safety to obtain the first information about its tolerability in different systems that are relevant for further decisions. There are, however, other studies that should be performed according to GLP standards and are mandatory for the safe exposure to humans, such as repeated dose toxicity, genotoxicity and safety pharmacology. These studies must be conducted before the Investigational New Drug (IND) application. The package of non-clinical studies should cover all information needed for the safe transposition of drugs from animals to humans, generally based on the non-observed adverse effect level (NOAEL) obtained from general toxicity studies. After IND approval, other GLP experiments for the evaluation of chronic toxicity, reproductive and developmental toxicity, carcinogenicity and genotoxicity, are carried out during the clinical phase of development. However, the necessity of performing such studies depends on the new drug clinical application purpose.

  19. PRELIMINARY EXPOSURE ASSESSMENT FINDINGS FROM THE TAMPA ASTHMATIC CHILDREN'S STUDY

    Science.gov (United States)

    The Tampa Asthmatic Children's Study (TACS) was a pilot study that focused on developing and evaluating air pollution exposure assessment methods and participant recruiting tools. The four-week study was performed in October and November, 2003. The study involved repeated daily...

  20. Estimation of kidneys and urinary bladder doses based on the region of interest in 18fluorine-fluorodeoxyglucose positron emission tomography/computed tomography examination: a preliminary study.

    Science.gov (United States)

    Mustapha, Farida Aimi; Bashah, Farahnaz Ahmad Anwar; Yassin, Ihsan M; Fathinul Fikri, Ahmad Saad; Nordin, Abdul Jalil; Abdul Razak, Hairil Rashmizal

    2017-06-01

    Kidneys and urinary bladder are common physiologic uptake sites of 18fluorine-fluorodeoxyglucose ( 18 F-FDG) causing increased exposure of low energy ionizing radiation to these organs. Accurate measurement of organ dose is vital as 18 F-FDG is directly exposed to the organs. Organ dose from 18 F-FDG PET is calculated according to the injected 18 F-FDG activity with the application of dose coefficients established by International Commission on Radiological Protection (ICRP). But this dose calculation technique is not directly measured from these organs; rather it is calculated based on total injected activity of radiotracer prior to scanning. This study estimated the 18 F-FDG dose to the kidneys and urinary bladder in whole body positron emission tomography/computed tomography (PET/CT) examination by comparing dose from total injected activity of 18 F-FDG (calculated dose) and dose from organs activity based on the region of interest (ROI) (measured dose). Nine subjects were injected intravenously with the mean 18 F-FDG dose of 292.42 MBq prior to whole body PET/CT scanning. Kidneys and urinary bladder doses were estimated by using two approaches which are the total injected activity of 18 F-FDG and organs activity concentration of 18 F-FDG based on drawn ROI with the application of recommended dose coefficients for 18 F-FDG described in the ICRP 80 and ICRP 106. The mean percentage difference between calculated dose and measured dose ranged from 98.95% to 99.29% for the kidneys based on ICRP 80 and 98.96% to 99.32% based on ICRP 106. Whilst, the mean percentage difference between calculated dose and measured dose was 97.08% and 97.27% for urinary bladder based on ICRP 80 while 96.99% and 97.28% based on ICRP 106. Whereas, the range of mean percentage difference between calculated and measured organ doses derived from ICRP 106 and ICRP 80 for kidney doses were from 17.00% to 40.00% and for urinary bladder dose was 18.46% to 18.75%. There is a significant

  1. Studies on image quality and dose exposure in chest radiography in children

    International Nuclear Information System (INIS)

    Schumacher, R.

    1985-01-01

    Chest radiography accounts for almost 50% of all radiographies in radiological departments for children, thus clearly dominating X-ray performances. The indications for examination in children are frequent infections of the upper airways, congenital cardiac defects, and controls in oncological patients. By contrast, indications for radioscopy of the chest organs which figure greatly in adult age and are often required concurrently with every chest radiography, are rather rare in the patient group of a paediatric X-ray department with their rate of c. 0.5% related to chest radiography. Chest radiographs and phantom radiographs were produced using different techniques and were compared by means of subjective and objective image quality parameters. Concurrently, thermoluminescence dosimetry was used to perform dose measurements of the small gonadal dose occurring in patients in chest radiographies. The study aimed at finding a chest radiography technique appropriate for use in paediatric radiology while considering both image quality parameters and the radiation dose required for producing pictures. (orig./DG) [de

  2. Validation of dose-response calibration curve for X-Ray field of CRCN-NE/CNEN: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Laís Melo; Mendonç, Julyanne Conceição de Goes; Andrade, Aida Mayra Guedes de; Hwang, Suy F.; Mendes, Mariana Esposito; Lima, Fabiana F., E-mail: falima@cnen.gov.br, E-mail: mendes_sb@hotmail.com [Centro Regional de Ciências Nucleares, (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Melo, Ana Maria M.A., E-mail: july_cgm@yahoo.com.br [Universidade Federal de Pernambuco (UFPE), Vitória de Santo Antão, PE (Brazil). Centro Acadêmico de Vitória

    2017-07-01

    It is very important in accident investigations that accurate estimating of absorbed dose takes place, so that it contributes to medical decisions and overall assessment of long-term health consequences. Analysis of chromosome aberrations is the most developed method for biological monitoring, and frequencies of dicentric chromosomes are related to absorbed dose of human peripheral blood lymphocytes using calibration curves. International Atomic Energy Agency (IAEA) recommends that each biodosimetry laboratory sets its own calibration curves, given that there are intrinsic differences in protocols and dose interpretations when using calibration curves produced in other laboratories, which could add further uncertainties to dose estimations. The Laboratory for Biological Dosimetry CRCN-NE recently completed dose-response calibration curves for X ray field. Curves of chromosomes dicentrics and dicentrics plus rings were made using Dose Estimate. This study aimed to validate the calibration curves dose-response for X ray with three irradiated samples. Blood was obtained by venipuncture from healthy volunteer and three samples were irradiated by x-rays of 250 kVp with different absorbed doses (0,5Gy, 1Gy and 2Gy). The irradiation was performed at the CRCN-NE/CNEN Metrology Service with PANTAK X-ray equipment, model HF 320. The frequency of dicentric and centric rings chromosomes were determined in 500 metaphases per sample after cultivation of lymphocytes, and staining with Giemsa 5%. Results showed that the estimated absorbed doses are included in the confidence interval of 95% of real absorbed dose. These Dose-response calibration curves (dicentrics and dicentrics plus rings) seems valid, therefore other tests will be done with different volunteers. (author)

  3. Validation of dose-response calibration curve for X-Ray field of CRCN-NE/CNEN: preliminary results

    International Nuclear Information System (INIS)

    Silva, Laís Melo; Mendonç, Julyanne Conceição de Goes; Andrade, Aida Mayra Guedes de; Hwang, Suy F.; Mendes, Mariana Esposito; Lima, Fabiana F.; Melo, Ana Maria M.A.

    2017-01-01

    It is very important in accident investigations that accurate estimating of absorbed dose takes place, so that it contributes to medical decisions and overall assessment of long-term health consequences. Analysis of chromosome aberrations is the most developed method for biological monitoring, and frequencies of dicentric chromosomes are related to absorbed dose of human peripheral blood lymphocytes using calibration curves. International Atomic Energy Agency (IAEA) recommends that each biodosimetry laboratory sets its own calibration curves, given that there are intrinsic differences in protocols and dose interpretations when using calibration curves produced in other laboratories, which could add further uncertainties to dose estimations. The Laboratory for Biological Dosimetry CRCN-NE recently completed dose-response calibration curves for X ray field. Curves of chromosomes dicentrics and dicentrics plus rings were made using Dose Estimate. This study aimed to validate the calibration curves dose-response for X ray with three irradiated samples. Blood was obtained by venipuncture from healthy volunteer and three samples were irradiated by x-rays of 250 kVp with different absorbed doses (0,5Gy, 1Gy and 2Gy). The irradiation was performed at the CRCN-NE/CNEN Metrology Service with PANTAK X-ray equipment, model HF 320. The frequency of dicentric and centric rings chromosomes were determined in 500 metaphases per sample after cultivation of lymphocytes, and staining with Giemsa 5%. Results showed that the estimated absorbed doses are included in the confidence interval of 95% of real absorbed dose. These Dose-response calibration curves (dicentrics and dicentrics plus rings) seems valid, therefore other tests will be done with different volunteers. (author)

  4. Quality Control in Mammography: Image Quality and Patient Doses

    International Nuclear Information System (INIS)

    Ciraj Bjelac, O.; Arandjic, D.; Boris Loncar, B.; Kosutic, D.

    2008-01-01

    Mammography is method of choice for early detection of breast cancer. The purpose of this paper is preliminary evaluation the mammography practice in Serbia, in terms of both quality control indicators, i.e. image quality and patient doses. The survey demonstrated considerable variations in technical parameters that affect image quality and patients doses. Mean glandular doses ranged from 0.12 to 2.8 mGy, while reference optical density ranged from 1.2 to 2.8. Correlation between image contrast and mean glandular doses was demonstrated. Systematic implementation of quality control protocol should provide satisfactory performance of mammography units and maintain satisfactory image quality and keep patient doses as low as reasonably practicable. (author)

  5. El prestigi empresarial: Anàlisi a través de les conselleries creuades The business prestige: A preliminary study based on interlocks within companies The business prestige: A preliminary study based on interlocks within companies

    Directory of Open Access Journals (Sweden)

    David Gonzalez-Prieto

    2011-11-01

    Full Text Available Purpose: The literature on interlocked directorate or interlocks has proposed the presence of cross-directors as an influential factor in the prestige of a firm (Mizruchi, 1996. This theory is based on the fact that, by having multiple companies with interlocks within them, major stakeholders of the company ought to have a higher perception of prestige. The aim of this preliminary study is to present an exploratory study and suggest future research lines on this issue. Design/methodology/approach: In a first preliminary study, we evaluate the interlocks network comprising companies belonging to the ranking established by the MERCO report in Spain for the year 2010. This is a well-known ranking of corporate reputation in Spain used in recent articles (Luna & Fernandez, 2010. For further analysis, other variables are considered as being quoted in the Spanish market benchmark index, IBEX 35, and the location of the headquarters.Findings: Significant positive relationship was obtained between the number of directorships shared with other public companies and the perceived prestige that stakeholders perceive from the firm. Similarly, we obtain significant positive correlation between the prestige and being listed on the IBEX 35. Finally, we identified banking, construction and energy sectors as the ones that use interlocking directorates more intensively.Research limitations: The results of this preliminary study show the viability of future studies about prestige and interlocks (Mizruchi, 1996. For the validation of the theory described in this study, it should be replicated in different regions and, with larger samples, to observe the effect that interlocks have on the perception of prestige of the company.Practical implications / Originality/value: This is among the first studies showing the existence of a relationship between interlocks and business prestige. It highlights the importance of the composition of the boards for the perceived prestige

  6. Trends in doses to some UK radiation workers

    International Nuclear Information System (INIS)

    Best, R.J.; Kendall, G.M.; Pook, E.A.; Saunders, P.J.

    1990-01-01

    The NRPB runs a Personal Monitoring Service which issues dosemeters and keeps radiation dose records for over 10 000 workers. This database is a valuable source of information on occupational exposure to radiation though it is likely that in future the Central Index of Dose Information (CIDI) will provide more comprehensive statistics, albeit restricted to radiation workers in the sense of Ionising Radiation Regulations. This note describes doses incurred to the end of 1987 with some preliminary figures for 1988. It does not cover the same ground as earlier reports but gives more details of the structure of the monitored population by age and sex and examines evidence that mean radiation doses are decreasing with time. (author)

  7. Preliminary clinical results from the EORTC 11961 trial at the petten irradiation facility

    International Nuclear Information System (INIS)

    Sauerwein, W.; Hideghety, K.; Vries, M.J. de

    2000-01-01

    Based on the pre-clinical work of the European Collaboration on Boron Neutron Capture Therapy a study protocol was prepared in 1995 to initiate Boron Neutron Capture Therapy (BNCT) in patients at the High Flux Reactor (HFR) in Petten. Bio-distribution and pharmacokinetics data of the boron drug Na 2 B 12 H 11 SH (BSH) as well as the radiobiological effects of BNCT with BSH in healthy brain tissue of dogs were considered in designing the strategy for this clinical Phase I trial. The primary goal of the radiation dose escalation study is the investigation of possible adverse events due to BNCT; i.e. to establish the dose limiting toxicity and the maximal tolerated radiation dose. The treatment is delivered in 4 fractions at a defined average boron concentration in blood. After an observation period of at least 6 months, the dose is increased by 10% for the next cohort. The preliminary results of the first cohort are presented here. The evaluated dose level can be considered to be safe. (author)

  8. Detection of small-bowel tumours with CT enteroclysis using carbon dioxide and virtual enteroscopy. A preliminary study

    International Nuclear Information System (INIS)

    Dohan, Anthony; Boudiaf, Mourad; Dautry, Raphael; Dray, Xavier; Samaha, Elia; Cellier, Christophe; Camus, Marine; Eveno, Clarisse; Soyer, Philippe

    2018-01-01

    The aim of this prospective study was to evaluate the feasibility, tolerance and performance of virtual enteroscopy (VE) using carbon dioxide for small-bowel distension in patients with suspected small-bowel tumours (SBTs). After IRB approval, 17 patients with suspected SBTs were prospectively included. Radiation dose was compared to 34 matched patients (2 for 1) for age, gender and body weight, who had undergone CT-enteroclysis with neutral contrast (CTE). Performance of VE was evaluated through comparison with the current standard of reference, including surgery and/or enteroscopy and/or follow-up. Tolerance was excellent in 16/17 patients (94%). The radiation dose was lower for VE than for CTE (533 ± 282 vs. 974 ± 505 mGy.cm; p = 0.002). With VE, a total of 25 polyps >5 mm in size were depicted in 12/17 patients. On a per-lesion analysis, sensitivity and positive predictive value of VE were 92.0% and 92.0%, respectively. On a per-segment analysis VE had a sensitivity and specificity of 95.0% and 87.0%, respectively. Our preliminary study suggests that VE is a feasible and well-tolerated technique with high sensitivity and specificity for the diagnosis of SBT. (orig.)

  9. Detection of small-bowel tumours with CT enteroclysis using carbon dioxide and virtual enteroscopy. A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Dohan, Anthony [Hopital Lariboisiere - Assistance Publique-Hopitaux de Paris, Department of Body and Interventional Imaging, Paris (France); Universite Sorbonne Paris Cite, Paris Diderot, INSERM UMR 965, Paris (France); Boudiaf, Mourad; Dautry, Raphael [Hopital Lariboisiere - Assistance Publique-Hopitaux de Paris, Department of Body and Interventional Imaging, Paris (France); Dray, Xavier [Department of Digestive Diseases, Hopital Saint-Antoine, Assistance Publique-Hopitaux de Paris, Paris (France); Sorbonne Universite, Paris (France); Samaha, Elia [European Georges Pompidou Hospital, Assistance Publique-Hopitaux de Paris, Gastroenterology and Endoscopy Unit, Paris (France); Cellier, Christophe [European Georges Pompidou Hospital, Assistance Publique-Hopitaux de Paris, Gastroenterology and Endoscopy Unit, Paris (France); Universite Sorbonne Paris Cite, Paris Descartes, Paris (France); Camus, Marine [Universite Sorbonne Paris Cite, Paris Descartes, Paris (France); Hopital Cochin - Assistance Publique-Hopitaux de Paris, Department of Gastroenterology, Paris (France); Eveno, Clarisse [Universite Sorbonne Paris Cite, Paris Diderot, INSERM UMR 965, Paris (France); Hopital Lariboisiere - Assistance Publique-Hopitaux de Paris, Department of Surgical Oncologic and Digestive Unit, Paris (France); Soyer, Philippe [Universite Sorbonne Paris Cite, Paris Diderot, INSERM UMR 965, Paris (France); Hopital Cochin - Assistance Publique-Hopitaux de Paris, Department of Body and Interventional Imaging, Paris (France)

    2018-01-15

    The aim of this prospective study was to evaluate the feasibility, tolerance and performance of virtual enteroscopy (VE) using carbon dioxide for small-bowel distension in patients with suspected small-bowel tumours (SBTs). After IRB approval, 17 patients with suspected SBTs were prospectively included. Radiation dose was compared to 34 matched patients (2 for 1) for age, gender and body weight, who had undergone CT-enteroclysis with neutral contrast (CTE). Performance of VE was evaluated through comparison with the current standard of reference, including surgery and/or enteroscopy and/or follow-up. Tolerance was excellent in 16/17 patients (94%). The radiation dose was lower for VE than for CTE (533 ± 282 vs. 974 ± 505 mGy.cm; p = 0.002). With VE, a total of 25 polyps >5 mm in size were depicted in 12/17 patients. On a per-lesion analysis, sensitivity and positive predictive value of VE were 92.0% and 92.0%, respectively. On a per-segment analysis VE had a sensitivity and specificity of 95.0% and 87.0%, respectively. Our preliminary study suggests that VE is a feasible and well-tolerated technique with high sensitivity and specificity for the diagnosis of SBT. (orig.)

  10. Comparison of pre-operative dGEMRIC imaging with intra-operative findings in femoroacetabular impingement: preliminary findings

    International Nuclear Information System (INIS)

    Bittersohl, Bernd; Apprich, Sebastian; Siebenrock, Klaus A.; Mamisch, Tallal Charles; Hosalkar, Harish S.; Werlen, Stefan A.

    2011-01-01

    To study standard MRI and dGEMRIC in patients with symptomatic FAI undergoing surgical intervention and compare them with intra-operative findings to see if they were corroborative. Sixteen patients with symptomatic FAI that warranted surgical intervention were prospectively studied. All patients underwent plain radiographic series for FAI assessment followed by standard MRI and dGEMRIC. Subsequently, patients were surgically treated with safe dislocation and the joint was evaluated for any macroscopic signs of damaged cartilage. Data were statistically analyzed. A total of 224 zones in 16 patients were evaluated. One hundred and sixteen zones were intra-operatively rated as normal with mean T1 values of 510.1 ms ± 141.2 ms. Eighty zones had evidence of damage with mean T1 values of 453.1 ms ± 113.6 ms. The difference in these T1 values was significant (p = 0.003). Correlation between standard MRI and intra-operative findings was moderate (r = 0.535, p < 0.001). Intra-operative findings revealed more damage than standard MRI. On standard MRI, 68.6% zones were graded normal while 31.4% had evidence of damage. On intra-operative visualization, 56.4% zones were graded normal and 43.6% had evidence of damage. Correlation between dGEMRIC and intra-operative findings turned out to be weak (r = 0.114, p < 0.126). On T1 assessment 31.4% of zones were graded as normal and 68.6% as damaged. dGEMRIC was significantly different between normal and affected cartilage based on intra-operative assessment. The correlation for morphological findings was limited, underestimating defects. By combining morphological with biochemical assessment dGEMRIC may play some role in the future to prognosticate outcomes and facilitate surgical planning and intervention. (orig.)

  11. In Vitro Exposure of Porcine Ovarian Follicular Cells to PCB 153 Alters Steroid Secretion But Not Their Viability—Preliminary Study

    Directory of Open Access Journals (Sweden)

    Ewa L. Gregoraszczuk

    2002-01-01

    Full Text Available In our previous paper[1], we demonstrated that porcine follicles collected during the early stage of development are the most sensitive to the toxic action of polychlorinated biphenyl 153 (PCB 153. Follicles of this type were collected to test the effect of PCB 153 on cell steroidogenesis and viability. Cocultures of granulosa and theca cells were grown in M199 medium at 37ºC. Control cultures were maintained in that medium alone, while experimental ones were supplemented with PCB 153 at doses of 5, 10, 50, and 100 ng/ml. After 48, 96, and 144 h, media were collected for steroid analysis and cell viability was measured using an LDH (lactate dehydrogenase activity cytotoxicity test. A 2-day exposure of follicular cells to all the investigated doses of PCB 153 caused a statistically significant decrease in progesterone (P4 secretion, while in doses of 50 and 100 ng/ml there was also a decrease in testosterone (T secretion. No effect on estradiol (E2 secretion was observed. The observed decrease in P4 and T secretion, and lack of any statistically significant effect on E2 secretion by cells from small follicles exposed for 48 h to PCB, suggests that PCB 153 acts before P4 formation. Longer exposures caused an increase in P4 secretion, with a concomitant drastic decrease in T secretion and a tendency to decrease the E2 secretion, suggesting inhibition of P450 17α hydroxysteroid dehydrogenase, an enzyme that converts P4 to T. The observed PCB 153–induced increase in P4 secretion by cells collected from small antral follicles, with a concomitant decrease in E2 secretion, accounts for the induction of luteinization and, in this case, inhibition of aromatization process in the follicles. However, in all doses tested and at all times of exposure, PCB 153 had no effect on cell viability. These findings suggest different time of exposure–dependent action of PCB 153 on particular steps of steroidogenesis but not action on cell viability. These results

  12. Effect of preliminary neutron irradiation on helium blistering of 0Kh16N15M3B steel

    International Nuclear Information System (INIS)

    Chernov, I.I.; Kalin, B.A.; Skorov, D.M.; Shishkin, G.N.; Ivanov, M.V.

    1982-01-01

    The method of electron microscopy has been applied to investigate the effect of preliminary neutron irradiation on the OKh16N15M3B steel blistering under irradiation by 20 keV helium ions with (1-10)x10 21 ion/m 2 doses at the temperature below 373 K. It is shown that neutron irradiation shifts critical doses of blister formation and intense scaling towards higher doses. But after the incubation period the erosion of steel preliminary neutron irradiated grows with the increase of helium ion dose above 7x10 21 ion/m 2 . Short-term heating of neutron irradiated samples during 15 min at 1173 K does not practically affect the beginning of intense scaling of the surface

  13. Preliminary study for small animal preclinical hadrontherapy facility

    Energy Technology Data Exchange (ETDEWEB)

    Russo, G. [Institute of Molecular Bioimaging and Physiology, IBFM CNR-LATO, Cefalú (Italy); Pisciotta, P., E-mail: pietro.pisciotta@ibfm.cnr.it [Institute of Molecular Bioimaging and Physiology, IBFM CNR-LATO, Cefalú (Italy); National Institute for Nuclear Physics, Laboratori Nazionali del Sud, INFN-LNS, Catania (Italy); Cirrone, G.A.P.; Romano, F. [National Institute for Nuclear Physics, Laboratori Nazionali del Sud, INFN-LNS, Catania (Italy); Cammarata, F.; Marchese, V.; Forte, G.I.; Lamia, D.; Minafra, L.; Bravatá, V. [Institute of Molecular Bioimaging and Physiology, IBFM CNR-LATO, Cefalú (Italy); Acquaviva, R. [University of Catania, Catania (Italy); Gilardi, M.C. [Institute of Molecular Bioimaging and Physiology, IBFM CNR-LATO, Cefalú (Italy); Cuttone, G. [National Institute for Nuclear Physics, Laboratori Nazionali del Sud, INFN-LNS, Catania (Italy)

    2017-02-21

    Aim of this work is the study of the preliminary steps to perform a particle treatment of cancer cells inoculated in small animals and to realize a preclinical hadrontherapy facility. A well-defined dosimetric protocol was developed to explicate the steps needed in order to perform a precise proton irradiation in small animals and achieve a highly conformal dose into the target. A precise homemade positioning and holding system for small animals was designed and developed at INFN-LNS in Catania (Italy), where an accurate Monte Carlo simulation was developed, using Geant4 code to simulate the treatment in order to choose the best animal position and perform accurately all the necessary dosimetric evaluations. The Geant4 application can also be used to realize dosimetric studies and its peculiarity consists in the possibility to introduce the real target composition in the simulation using the DICOM micro-CT image. This application was fully validated comparing the results with the experimental measurements. The latter ones were performed at the CATANA (Centro di AdroTerapia e Applicazioni Nucleari Avanzate) facility at INFN-LNS by irradiating both PMMA and water solid phantom. Dosimetric measurements were performed using previously calibrated EBT3 Gafchromic films as a detector and the results were compared with the Geant4 simulation ones. In particular, two different types of dosimetric studies were performed: the first one involved irradiation of a phantom made up of water solid slabs where a layer of EBT3 was alternated with two different slabs in a sandwich configuration, in order to validate the dosimetric distribution. The second one involved irradiation of a PMMA phantom made up of a half hemisphere and some PMMA slabs in order to simulate a subcutaneous tumour configuration, normally used in preclinical studies. In order to evaluate the accordance between experimental and simulation results, two different statistical tests were made: Kolmogorov test and

  14. Preliminary study for small animal preclinical hadrontherapy facility

    Science.gov (United States)

    Russo, G.; Pisciotta, P.; Cirrone, G. A. P.; Romano, F.; Cammarata, F.; Marchese, V.; Forte, G. I.; Lamia, D.; Minafra, L.; Bravatá, V.; Acquaviva, R.; Gilardi, M. C.; Cuttone, G.

    2017-02-01

    Aim of this work is the study of the preliminary steps to perform a particle treatment of cancer cells inoculated in small animals and to realize a preclinical hadrontherapy facility. A well-defined dosimetric protocol was developed to explicate the steps needed in order to perform a precise proton irradiation in small animals and achieve a highly conformal dose into the target. A precise homemade positioning and holding system for small animals was designed and developed at INFN-LNS in Catania (Italy), where an accurate Monte Carlo simulation was developed, using Geant4 code to simulate the treatment in order to choose the best animal position and perform accurately all the necessary dosimetric evaluations. The Geant4 application can also be used to realize dosimetric studies and its peculiarity consists in the possibility to introduce the real target composition in the simulation using the DICOM micro-CT image. This application was fully validated comparing the results with the experimental measurements. The latter ones were performed at the CATANA (Centro di AdroTerapia e Applicazioni Nucleari Avanzate) facility at INFN-LNS by irradiating both PMMA and water solid phantom. Dosimetric measurements were performed using previously calibrated EBT3 Gafchromic films as a detector and the results were compared with the Geant4 simulation ones. In particular, two different types of dosimetric studies were performed: the first one involved irradiation of a phantom made up of water solid slabs where a layer of EBT3 was alternated with two different slabs in a sandwich configuration, in order to validate the dosimetric distribution. The second one involved irradiation of a PMMA phantom made up of a half hemisphere and some PMMA slabs in order to simulate a subcutaneous tumour configuration, normally used in preclinical studies. In order to evaluate the accordance between experimental and simulation results, two different statistical tests were made: Kolmogorov test and

  15. Preliminary study for small animal preclinical hadrontherapy facility

    International Nuclear Information System (INIS)

    Russo, G.; Pisciotta, P.; Cirrone, G.A.P.; Romano, F.; Cammarata, F.; Marchese, V.; Forte, G.I.; Lamia, D.; Minafra, L.; Bravatá, V.; Acquaviva, R.; Gilardi, M.C.; Cuttone, G.

    2017-01-01

    Aim of this work is the study of the preliminary steps to perform a particle treatment of cancer cells inoculated in small animals and to realize a preclinical hadrontherapy facility. A well-defined dosimetric protocol was developed to explicate the steps needed in order to perform a precise proton irradiation in small animals and achieve a highly conformal dose into the target. A precise homemade positioning and holding system for small animals was designed and developed at INFN-LNS in Catania (Italy), where an accurate Monte Carlo simulation was developed, using Geant4 code to simulate the treatment in order to choose the best animal position and perform accurately all the necessary dosimetric evaluations. The Geant4 application can also be used to realize dosimetric studies and its peculiarity consists in the possibility to introduce the real target composition in the simulation using the DICOM micro-CT image. This application was fully validated comparing the results with the experimental measurements. The latter ones were performed at the CATANA (Centro di AdroTerapia e Applicazioni Nucleari Avanzate) facility at INFN-LNS by irradiating both PMMA and water solid phantom. Dosimetric measurements were performed using previously calibrated EBT3 Gafchromic films as a detector and the results were compared with the Geant4 simulation ones. In particular, two different types of dosimetric studies were performed: the first one involved irradiation of a phantom made up of water solid slabs where a layer of EBT3 was alternated with two different slabs in a sandwich configuration, in order to validate the dosimetric distribution. The second one involved irradiation of a PMMA phantom made up of a half hemisphere and some PMMA slabs in order to simulate a subcutaneous tumour configuration, normally used in preclinical studies. In order to evaluate the accordance between experimental and simulation results, two different statistical tests were made: Kolmogorov test and

  16. SU-F-J-38: Dose Rates and Preliminary Evaluation of Contouring Similarity Metrics Using 4D Cone Beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Santoso, A [Wayne State University School of Medicine, Detroit, Michigan (United States); Song, K; Qin, Y; Gardner, S; Liu, C; Cattaneo, R; Chetty, I; Movsas, B; Aljouni, M; Wen, N [Henry Ford Health System, Detroit, MI (United States)

    2016-06-15

    Purpose: 4D imaging modalities require detailed characterization for clinical optimization. The On-Board Imager mounted on the linear accelerator was used to investigate dose rates in a tissue mimicking phantom using 4D-CBCT and assess variability of contouring similarity metrics between 4D-CT and 4D-CBCT retrospective reconstructions. Methods: A 125 kVp thoracic protocol was used. A phantom placed on a motion platform simulated a patient’s breathing cycle. An ion chamber was affixed inside the phantom’s tissue mimicking cavities (i.e. bone, lung, and soft tissue). A sinusoidal motion waveform was executed with a five second period and superior-inferior motion. Dose rates were measured at six ion chamber positions. A preliminary workflow for contouring similarity between 4D-CT and 4D-CBCT was established using a single lung SBRT patient’s historical data. Average intensity projection (Ave-IP) and maximum intensity projection (MIP) reconstructions generated offline were compared between the 4D modalities. Similarity metrics included Dice similarity coefficient (DSC), Hausdorff distance, and center of mass (COM) deviation. Two isolated lesions were evaluated in the patient’s scans: one located in the right lower lobe (ITVRLL) and one located in the left lower lobe (ITVLLL). Results: Dose rates ranged from 2.30 (lung) to 5.18 (bone) E-3 cGy/mAs. For fixed acquisition parameters, cumulative dose is inversely proportional to gantry speed. For ITVRLL, DSC were 0.70 and 0.68, Hausdorff distances were 6.11 and 5.69 mm, and COM deviations were 1.24 and 4.77 mm, for Ave-IP and MIP respectively. For ITVLLL, DSC were 0.64 and 0.75, Hausdorff distances were 10.74 and 8.00 mm, and COM deviations were 7.55 and 4.3 mm, for Ave-IP and MIP respectively. Conclusion: While the dosimetric output of 4D-CBCT is low, characterization is necessary to assure clinical optimization. A basic workflow for comparison of simulation and treatment 4D image-based contours was established

  17. Doses to patients and staff from endovascular treatment of abdominal aortic aneurysms - Preliminary results

    International Nuclear Information System (INIS)

    Bjoerklund, E.G.; Widmark, A.; Gjoelberg, T.; Bay, D.; Joergensen, J.J.; Staxrud, L.E.

    2001-01-01

    Patient radiation doses received during endovascular treatment of abdominal aortic aneurysms (AAA) can be significant and give rise to both deterministic and stochastic effects. Recording of dose-area product (DAP), fluoroscopy time and number of exposures together with calculations of effective dose, were performed for 8 patients. In addition, the entrance surface dose was measured for 3 of the patients. Typically, DAPs of 340 Gycm 2 , fluoroscopy times of 30 minutes and 310 exposures were obtained together with maximum entrance surface doses of 1,8 Gy and effective doses of 50 mSv. Finger doses to the staff performing the procedure were in the order of a few hundred μSv. Conversion factors (effective dose/DAP) and (maximum entrance surface does/DAP) of 0,61·10 -2 Gy/Gycm 2 and 0,15 mSv/Gycm 2 were obtained, respectively. (author)

  18. Development of internal dose assessment procedure for workers in industries using raw materials containing naturally occurring radioactive materials

    International Nuclear Information System (INIS)

    Choi, Cheol Kyu; KIm, Yong Geon; Ji, Seung Woo; Kim, Kwang Pyo; Koo, Bon Cheol; Chang, Byung Uck

    2016-01-01

    It is necessary to assess radiation dose to workers due to inhalation of airborne particulates containing naturally occurring radioactive materials (NORM) to ensure radiological safety required by the Natural Radiation Safety Management Act. The objective of this study is to develop an internal dose assessment procedure for workers at industries using raw materials containing natural radionuclides. The dose assessment procedure was developed based on harmonization, accuracy, and proportionality. The procedure includes determination of dose assessment necessity, preliminary dose estimation, airborne particulate sampling and characterization, and detailed assessment of radiation dose. The developed dose assessment procedure is as follows. Radioactivity concentration criteria to determine dose assessment necessity are 10 Bq·g-1 for 40K and 1 Bq·g-1 for the other natural radionuclides. The preliminary dose estimation is performed using annual limit on intake (ALI). The estimated doses are classified into 3 groups (<0.1 mSv, 0.1-0.3 mSv, and >0.3 mSv). Air sampling methods are determined based on the dose estimates. Detailed dose assessment is performed using air sampling and particulate characterization. The final dose results are classified into 4 different levels (<0.1 mSv, 0.1-0.3 mSv, 0.3-1 mSv, and >1 mSv). Proper radiation protection measures are suggested according to the dose level. The developed dose assessment procedure was applied for NORM industries in Korea, including coal combustion, phosphate processing, and monazite handing facilities. The developed procedure provides consistent dose assessment results and contributes to the establishment of optimization of radiological protection in NORM industries

  19. Development of internal dose assessment procedure for workers in industries using raw materials containing naturally occurring radioactive materials

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Cheol Kyu; KIm, Yong Geon; Ji, Seung Woo; Kim, Kwang Pyo [College of Engineering, Kyung Hee University, Yongin (Korea, Republic of); Koo, Bon Cheol; Chang, Byung Uck [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2016-09-15

    It is necessary to assess radiation dose to workers due to inhalation of airborne particulates containing naturally occurring radioactive materials (NORM) to ensure radiological safety required by the Natural Radiation Safety Management Act. The objective of this study is to develop an internal dose assessment procedure for workers at industries using raw materials containing natural radionuclides. The dose assessment procedure was developed based on harmonization, accuracy, and proportionality. The procedure includes determination of dose assessment necessity, preliminary dose estimation, airborne particulate sampling and characterization, and detailed assessment of radiation dose. The developed dose assessment procedure is as follows. Radioactivity concentration criteria to determine dose assessment necessity are 10 Bq·g-1 for 40K and 1 Bq·g-1 for the other natural radionuclides. The preliminary dose estimation is performed using annual limit on intake (ALI). The estimated doses are classified into 3 groups (<0.1 mSv, 0.1-0.3 mSv, and >0.3 mSv). Air sampling methods are determined based on the dose estimates. Detailed dose assessment is performed using air sampling and particulate characterization. The final dose results are classified into 4 different levels (<0.1 mSv, 0.1-0.3 mSv, 0.3-1 mSv, and >1 mSv). Proper radiation protection measures are suggested according to the dose level. The developed dose assessment procedure was applied for NORM industries in Korea, including coal combustion, phosphate processing, and monazite handing facilities. The developed procedure provides consistent dose assessment results and contributes to the establishment of optimization of radiological protection in NORM industries.

  20. Biological effective dose studies in carcinoma of uterine cervix

    International Nuclear Information System (INIS)

    Yadav, Poonam; Ramasubramanian, V.

    2008-01-01

    Cancer of cervix is the second most common cancer worldwide among women. Several treatments related protocols of radiotherapy have been followed over few decades in its treatment for evaluating the response. These physical doses varying on the basics of fractionation size, dose rate and total dose needed to be indicated as biological effective dose (BED) to rationalize these treatments. The curative potential of radiation therapy in the management of carcinoma of the cervix is greatly enhanced by the use of intracavitary brachytherapy. Successful brachytherapy requires the high radiation dose to be delivered to the tumor where as minimum radiation dose reach to surrounding normal tissue. Present study is aimed to evaluate biologically effective dose in patients receiving high dose-rate brachytherapy plus external beam radiotherapy based on tumor cell proliferation values in cancer of the cervix patients. The study includes 30 patients' data as a retrospective analysis. In addition determine extent of a dose-response relationship existing between the biological effective dose at Point A and the bladder and rectum and the clinical outcomes

  1. High-resolution CT findings in infants with bronchopulmonary dysplasia: preliminary report

    International Nuclear Information System (INIS)

    Chung, Yoon Ho; Lee, Young Seok; Kim, Ji Hye; Han, Heon; Chung, Hyo Sun; Cha, Yoo Mi; Kim, Young Chae; Kim, Sang Hee

    1996-01-01

    To evaluate high resolution CT(HRCT) findings in infants with bronchopulmonary dysplasia(BPD). In 13 infants(age range, 1-12 months;11 premature babies, two full-term babies; birth weight, 0.97-3.88kg;mean 2,03kg) with clinico-radiologically suggested BPD, HRCT findings of the lung were reviewed retrospectively. Spiral CT using ultra high bone algorithm, 1mm collimation with 5-8mm interval, and 0.7sec scan time was performed without regard to breathing-control of infants. Three radiologists each analysed the HRCT findings twice. HRCT findings of BPD were as follows:parenchymal bands(n=13), interlobular septal thickenings (n=12), multifocal hyperaeration involving lobar or segmental distribution(n=7), and involving lobular distribution or small cyst-like lesion(n=4), centrilobular nodules(n=7), consolidation and/or atelectasis(n=7), and bronchovascular bundle thickening(n=6). Parenchymal bands, interlobular septal thickenings, and multifocal hyperaerations were the major findings in cases of bronchopulmonary dysplasia whereas, centrilobular nodules, consolidation and/or atelectasis, and bronchovascular bundle thickenings were the minor findings. These findings may be used as basic data in the evaluation of BPD in future studies

  2. Preliminary Findings from an Analysis of Building Energy Information System Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Granderson, Jessica; Piette, Mary Ann; Ghatikar, Girish; Price, Philip

    2009-06-01

    Energy information systems comprise software, data acquisition hardware, and communication systems that are intended to provide energy information to building energy and facilities managers, financial managers, and utilities. This technology has been commercially available for over a decade, however recent advances in Internet and other information technology, and analytical features have expanded the number of product options that are available. For example, features such as green house gas tracking, configurable energy analyses and enhanced interoperability are becoming increasingly common. Energy information systems are used in a variety of commercial buildings operations and environments, and can be characterized in a number of ways. Basic elements of these systems include web-based energy monitoring, web-based energy management linked to controls, demand response, and enterprise energy management applications. However the sheer number and variety of available systems complicate the selection of products to match the needs of a given user. In response, a framework was developed to define the capabilities of different types of energy information systems, and was applied to characterize approximately 30 technologies. Measurement is a critical component in managing energy consumption and energy information must be shared at all organizational levels to maintain persistent, efficient operations. Energy information systems are important to understand because they offer the analytical support to process measured data into information, and they provide the informational link between the primary actors who impact building energy efficiency - operators, facilities and energy managers, owners and corporate decision makers. In this paper, preliminary findings are presented, with a focus on overall trends and the general state of the technology. Key conclusions include the need to further pursue standardization and usability, x-y plotting as an under-supported feature, and

  3. Comparing shame in clinical and nonclinical populations: Preliminary findings.

    Science.gov (United States)

    Dyer, Kevin F W; Dorahy, Martin J; Corry, Mary; Black, Rebecca; Matheson, Laura; Coles, Holly; Curran, David; Seager, Lenaire; Middleton, Warwick

    2017-03-01

    To conduct a preliminary study comparing different trauma and clinical populations on types of shame coping style and levels of state shame and guilt. A mixed independent groups/correlational design was employed. Participants were recruited by convenience sampling of 3 clinical populations-complex trauma (n = 65), dissociative identity disorder (DID; n = 20), and general mental health (n = 41)-and a control group of healthy volunteers (n = 125). All participants were given (a) the Compass of Shame Scale, which measures the four common shame coping behaviors/styles of "withdrawal," "attack self," "attack other," and "avoidance," and (b) the State Shame and Guilt Scale, which assesses state shame, guilt, and pride. The DID group exhibited significantly higher levels of "attack self," "withdrawal," and "avoidance" relative to the other groups. The complex trauma and general mental health groups did not differ on any shame variable. All three clinical groups had significantly greater levels of the "withdrawal" coping style and significantly impaired shame/guilt/pride relative to the healthy volunteers. "Attack self" emerged as a significant predictor of increased state shame in the complex trauma, general mental health, and healthy volunteer groups, whereas "withdrawal" was the sole predictor of state shame in the DID group. DID emerged as having a different profile of shame processes compared to the other clinical groups, whereas the complex trauma and general mental health groups had comparable shame levels and variable relationships. These differential profiles of shame coping and state shame are discussed with reference to assessment and treatment. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  4. Utilizing placebo mechanisms for dose reduction in pharmacotherapy.

    Science.gov (United States)

    Doering, Bettina K; Rief, Winfried

    2012-03-01

    The knowledge and systematic application of the placebo effect remains limited, although its importance to the treatment of various medical conditions has increasingly been recognized. A possible application of the placebo effect to pharmacotherapy is seen in conditioning processes that aim at a placebo-controlled dose reduction of drugs while maintaining the efficacy of the medical treatment. The pairing of a placebo and a pharmacological agent may achieve satisfactory treatment outcomes in combination with a lower dose of medication. This procedure includes classic and instrumental conditioning processes that involve both conscious and non-conscious information processing. Although recent studies have gathered preliminary evidence for the efficacy of placebo-controlled dose reduction (e.g. in psoriasis and attention deficit hyperactivity disorder [ADHD]), they have also illustrated the difficulties that are inherent to this approach. We critically review previous approaches and discuss designs for clinical trials that seem appropriate to the investigation of conditioned placebo effects in pharmacotherapy. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Switching From Age-Based Stimulus Dosing to Dose Titration Protocols in Electroconvulsive Therapy: Empirical Evidence for Better Patient Outcomes With Lower Peak and Cumulative Energy Doses.

    Science.gov (United States)

    O'Neill-Kerr, Alex; Yassin, Anhar; Rogers, Stephen; Cornish, Janie

    2017-09-01

    The aim of this study was to test the proposition that adoption of a dose titration protocol may be associated with better patient outcomes, at lower treatment dose, and with comparable cumulative dose to that in patients treated using an age-based stimulus dosing protocol. This was an analysis of data assembled from archived records and based on cohorts of patients treated respectively on an age-based stimulus dosing protocol and on a dose titration protocol in the National Health Service in England. We demonstrated a significantly better response in the patient cohort treated with dose titration than with age-based stimulus dosing. Peak doses were less and the total cumulative dose was less in the dose titration group than in the age-based stimulus dosing group. Our findings are consistent with superior outcomes in patients treated using a dose titration protocol when compared with age-based stimulus dosing in a similar cohort of patients.

  6. The TIMSS Videotape Classroom Study: Methods and Findings from an Exploratory Research Project on Eighth-Grade Mathematics Instruction in Germany, Japan, and the United States.

    Science.gov (United States)

    Stigler, James W.; Gonzales, Patrick; Kawanaka, Takako; Knoll, Steffen; Serrano, Ana

    1999-01-01

    Describes the methods and preliminary findings of the Videotape Classroom Study, a video survey of eighth-grade mathematics lessons in Germany, Japan, and the United States. Part of the Third International Mathematics and Science study, this research project is the first study of videotaped records from national probability samples. (SLD)

  7. Preliminary study of long-term wind characteristics of the Mexican Yucatan Peninsula

    International Nuclear Information System (INIS)

    Soler-Bientz, Rolando; Watson, Simon; Infield, David

    2009-01-01

    Mexico's Yucatan Peninsula is one of the most promising areas for wind energy development within the Latin American region but no comprehensive assessment of wind resource has been previously published. This research presents a preliminary analysis of the meteorological parameters relevant to the wind resource in order to find patterns in their long-term behaviour and to establish a foundation for subsequent research into the wind power potential of the Yucatan Peninsula. Three meteorological stations with data measured for a period between 10 and 20 years were used in this study. The monthly trends of ambient temperature, atmospheric pressure and wind speed data were identified and are discussed. The directional behaviour of the winds, their frequency distributions and the related Weibull parameters are presented. Wind power densities for the study sites have been estimated and have been shown to be relatively low (wind power class 1), though a larger number of suitable sites needs to be studied before a definitive resource evaluation can be reported.

  8. Dose finding of melatonin for chronic idiopathic childhood sleep onset insomnia: an RCT.

    NARCIS (Netherlands)

    van Geijlswijk, I.M.; van der Heijden, K.B.; Egberts, A.C.G.; Korzilius, H.P.; Smits, M.G.

    2010-01-01

    RATIONALE: Pharmacokinetics of melatonin in children might differ from that in adults. OBJECTIVES: This study aims to establish a dose-response relationship for melatonin in advancing dim light melatonin onset (DLMO), sleep onset (SO), and reducing sleep onset latency (SOL) in children between 6 and

  9. Doses from portable gauges

    International Nuclear Information System (INIS)

    Linauskas, S.H.

    1988-08-01

    Field studies to measure actual radiation exposures of operators of commercial moisture-density gauges were undertaken in several regions of Canada. Newly developed bubble detector dosimeter technology and conventional dosimetry such as thermoluminescent dosimeters (TLDs), integrating electronic dosimeters (DRDs), and CR-39 neutron track-etch detectors were used to estimate the doses received by 23 moisture-density gauge operators and maintenance staff. These radiation dose estimates were supported by mapping radiation fields and accounting for the time an operator was near a gauge. Major findings indicate that gauge maintenance and servicing workers were more likely than gauge operators to receive exposures above the level of 5 mSv, and that neutron doses were roughly the same as gamma doses. Gauge operators receive approximately 75% of their dose when transporting and carrying the gauge. Dose to their hands is similar to the dose to their trunks, but the dose to their feet area is 6 to 30 times higher. Gamma radiation is the primary source of radiation contributing to operator dose

  10. Preliminary measurements of gamma radiation in Chilean Antarctic Stations

    Energy Technology Data Exchange (ETDEWEB)

    Stuardo B, E. (Comision Chilena de Energia Nuclear, Santiago. Dept. de Aplicaciones Nucleares)

    1983-11-01

    Natural and artificial gamma radiation, 1 m above the soil, is being investigated in 4 Chilean Antartic Stations. The measurements are performed with different types of TLD detectors. Preliminary results in the Tte. Marsh Station are reported and discussed. An average exposition of 3,5 ..mu..R/h was found during a 108 days period. This exposition corresponds to an annual dose of about 40 mrad, 8% of the annual dose limit for individual of the public. The presence of low energy artificial radioisotopes was not found.

  11. Smoking Topography in Korean American and White Men: Preliminary Findings

    Science.gov (United States)

    Chung, Sangkeun; Kim, Sun S; Kini, Nisha; Fang, Hua J; Kalman, David; Ziedonis, Douglas M.

    2013-01-01

    Introduction This is the first study of Korean Americans’ smoking behavior using a topography device. Korean American men smoke at higher rates than the general U.S. population. Methods Korean American and White men were compared based on standard tobacco assessment and smoking topography measures. They smoked their preferred brand of cigarettes ad libitum with a portable smoking topography device for 24 hours. Results Compared to White men (N = 26), Korean American men (N = 27) were more likely to smoke low nicotine-yield cigarettes (p < 0.001) and have lower Fagerstrom nicotine dependence scores (p = 0.04). Koreans smoked fewer cigarettes with the device (p = 0.01) than Whites. Controlling for the number of cigarettes smoked, Koreans smoked with higher average puff flows (p = 0.05), greater peak puff flows (p = 0.02), and shorter interpuff intervals (p < 0.001) than Whites. Puff counts, puff volumes, and puff durations did not differ between the two groups. Conclusions This study offers preliminary insight into unique smoking patterns among Korean American men who are likely to smoke low nicotine-yield cigarettes. We found that Korean American men compensated their lower number and low nicotine-yield cigarettes by smoking more frequently with greater puff flows than White men, which may suggest exposures to similar amounts of nicotine and harmful tobacco toxins by both groups. Clinicians will need to consider in identifying and treating smokers in a mutually aggressive manner, irrespective of cigarette type and number of cigarette smoked per day. PMID:24068611

  12. Benefit finding for Chinese family caregivers of community-dwelling stroke survivors: A cross-sectional study.

    Science.gov (United States)

    Mei, Yongxia; Wilson, Susan; Lin, Beilei; Li, Yingshuang; Zhang, Zhenxiang

    2018-04-01

    To identify whether benefit finding is a mediator or moderator in the relationship between caregiver burden and psychological well-being (anxiety and depression) in Chinese family caregivers of community-dwelling stroke survivors. Family caregivers not only bear a heavy burden, a high level of anxiety and depression, but also experience benefit finding (positive effects result from stressful events). However, the relationships among benefit finding, caregiver burden and psychological well-being in Chinese family caregivers are not well known. This study was a cross-sectional correlational design. Caregivers (n = 145) of stroke survivors were recruited from two communities in Zhengzhou, China. Data were collected by face-to-face interviews with structured questionnaires, examining caregiver burden, benefit finding and psychological well-being of caregivers. A hierarchical regression analysis explored whether caregiver burden and benefit finding were associated with anxiety and depression of caregivers. The moderator role of benefit finding was examined by testing the significance of the interaction between caregiver burden and benefit finding. A mediational model was used to test benefit finding as a mediator between caregiver burden and psychological well-being of caregivers using process in spss 21.0. Caregiver burden and benefit finding were significantly associated with both anxiety and depression of caregivers. Benefit finding did not portray a moderating role, but portrayed the mediator role in the relationship between caregiver burden, anxiety and depression in caregivers. This study provides the preliminary evidence to nurses that intervention focus on benefit finding may help improve the psychological well-being of caregivers. This study offers nurses rational for assessing caregiver's negative emotions and benefit finding. By targeting benefit finding, the nurse may guide caregivers in benefit identification and implement interventions to reduce anxiety

  13. Emergent Literacy in Thai Preschoolers: A Preliminary Study.

    Science.gov (United States)

    Yampratoom, Ramorn; Aroonyadech, Nawarat; Ruangdaraganon, Nichara; Roongpraiwan, Rawiwan; Kositprapa, Jariya

    To investigate emergent literacy skills, including phonological awareness when presented with an initial phoneme-matching task and letter knowledge when presented with a letter-naming task in Thai preschoolers, and to identify key factors associated with those skills. Four hundred twelve typically developing children in their final kindergarten year were enrolled in this study. Their emergent reading skills were measured by initial phoneme-matching and letter-naming tasks. Determinant variables, such as parents' education and teachers' perception, were collected by self-report questionnaires. The mean score of the initial phoneme-matching task was 4.5 (45% of a total of 10 scores). The mean score of the letter-naming task without a picture representing the target letter name was 30.2 (68.6% of a total of 44 scores), which increased to 38.8 (88.2% of a total of 44 scores) in the letter-naming task when a picture representing the target letter name was provided. Both initial phoneme-matching and letter-naming abilities were associated with the mother's education and household income. Letter-naming ability was also influenced by home reading activities and gender. This was a preliminary study into emergent literacy skills of Thai preschoolers. The findings supported the importance of focusing on phonological awareness and phonics, especially in the socioeconomic disadvantaged group.

  14. [Effect of supplementation with a single dose of vitamin D in children with cerebral palsy. Preliminary randomised controlled study].

    Science.gov (United States)

    Le Roy, Catalina; Meier, Martina; Witting, Scarlett; Pérez-Bravo, Francisco; Solano, Carlos; Castillo-Durán, Carlos

    2015-01-01

    Children with cerebral palsy (CP) have an increased risk of vitamin D (VD) deficiency. Although there are many studies on VD and CP, there is limited information about VD supplementation in these patients. To evaluate the effect of supplementation with a single dose of VD on the plasma concentrations of 25-hydroxy-vitamin-D (25OHD) in children with CP. Prospective-randomised-controlled-trial, including 30 Chilean children (19 males) with CP, median age 9.9 years (6.2-13.5). Clinical and biochemical variables including 25OHD, were recorded (time 0 and 8 weeks). Patients were allocated to the supplemented (S) group receiving 100,000 IU oral D3 at baseline, and compared with the placebo (P) group. Among clinical features are highlighted: gastrostomy (60%), underweight (30%), bed-ridden (93.3%), antiepileptic drugs (70%), and 43.3% used VD metabolism inducing antiepileptics. Baseline biochemical measurements were normal. The 25OHD was insufficient in 4/30 and deficient in 6/30. 25OHD levels were not associated with the variables studied. Eight patients completed the study in the S group, and 10 in P group. The placebo and supplementation groups had no significant difference in baseline variables. Serum calcium, phosphate, and alkaline phosphatase levels at 8 weeks were normal in both groups, with no statistically significant differences. 25OHD in the P group was normal in 6/10, and insufficient+deficient in 4/10, and the S group was normal in all (8/8) (exact Fisher test P=.07). A single dose of 100,000 IU VD could normalise the concentrations of 25OHD after 8 weeks of supplementation in Children with CP, but more studies are required to confirm these results. Copyright © 2015 Sociedad Chilena de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. TU-F-CAMPUS-I-03: Preliminary Study of Size-Specific Dose Estimates in Adult Abdomenal CT Examinations in Taiwan

    International Nuclear Information System (INIS)

    Tsai, H; Hu, Y; Hwang, Y

    2015-01-01

    Purpose: This study was to investigate size-specific dose estimates (SSDE) for routine adult abdominal CT examinations in Taiwan. Methods: A national survey was conducted in Taiwan in 2014 to investigate SSDEs for routine adult abdominal CT examinations. The hospitals involved in this study provided CT images of their typical patients. The CT image in the level of the middle liver was selected to record the corresponding tube current, slice mAs or effective mAs. The image was also used to estimate the dimensions of patient as measuring the lengths in the anterior to posterior (AP) and lateral (LAT) directions. The effective diameter was then calculated from AP and LAT, and used to look up conversion factors in the AAPM 204 report. The volume CTDI (CTDIvol) for each CT unit was measured on sites using a 32-cm cylindrical standard dose phantom and a calibrated pencil-type ionization chamber. Individual patient’s SSDEs were then calculated from the corresponding SSDE conversion factor and the CTDIvol. Results: The study cohort included 111 CT units. The ratio of turning on automatic tube current modulation (ATCM) or not is 88:23. Effective diameters are 258.7±25.1 mm (167–366 mm). 99.3% of typical patients selected by each hospital have smaller effective diameter than the 32-cm dosimetry phantom. Adult abdomenal SSDE is 17.5 ± 8.8 mGy (1.9-58 mGy). The SSDE seems to decrease as the effective diameter increases as the ATCM turns off, and independent with the effective diameter as the ATCM turns on. Conclusion: The SSDE for typical patients in Taiwan was investigated. We continue to complete this investigation in 2015 to include more valid data to establish SSDE reference level in Taiwan. This study was financially supported by the Atomic Energy Council in Taiwan

  16. Production, quality control, biodistribution assessment and preliminary dose evaluation of {sup 166}Ho-alendronate as a bone marrow ablative agent

    Energy Technology Data Exchange (ETDEWEB)

    Fakhari, Ashraf [Tehran University of Medical Sciences (Iran, Islamic Republic of). Dept. of Radiopharmacy; Jalilian, Amir Reza; Yousefnia, Hassan; Zolghadri, Samaneh; Samani, Ali Bahrami; Akbari, Mahmoud Reza; Deha, Fariba Johari [Nuclear Science and Technology Research Institute (NSTRI), Tehran (Iran, Islamic Republic of); Shafiee-Ardestani, Mahdi; Khalaj, Ali [Tehran University of Medical Sciences (Iran, Islamic Republic of). Dept. of Medicinal Chemistry

    2015-07-01

    In this study, production, quality control and biodistribution studies of {sup 166}Ho-alendronate have been presented and followed by dosimetric evaluation for human based on biodistribution data in wild-type rats. {sup 166}Ho chloride was obtained by thermal neutron irradiation of natural {sup 165}Ho(NO{sub 3}){sub 3} samples. {sup 166}Ho-alendronate complex was prepared by adding the desired amount of alkaline alendronate solution (0.2 mL, 150 mg/mL) to 3-5 mCi of the {sup 166}HoCl{sub 3} solution. Radiochemical purity of the complex was monitored by instant thin layer chromatography (ITLC). {sup 166}Ho-alendronate complex was prepared in high radiochemical purity (> 99%, ITLC) and specific activity of 4.4 GBq/mmol. Stability studies of the complex in the final preparation and in the presence of human serum were performed up to 48 h. The major accumulation of the radio-complex was in the bone tissues followed by absorbed dose evaluation of each human organ by RADAR software used for modelling the radiation dose delivered. The final preparation was administered to wild-type rats and biodistribution of the complex was performed 2-48 h post injection showing major accumulation of the complex in the bone tissue. The highest absorbed dose for {sup 166}Ho-alendronate is observed in bone surface and red marrow with 2.670 and 1.880 mSv/MBq; respectively. These findings suggest that {sup 166}Ho-alendronate has considerable characteristics compared to {sup 166}Ho-DOTMP and can be a possible candidate for bone marrow ablation in patients with multiple myeloma.

  17. Preliminary summary of the ETF conceptual studies

    Science.gov (United States)

    Seikel, G. R.; Bercaw, R. W.; Pearson, C. V.; Owens, W. R.

    1978-01-01

    Power plant studies have shown the attractiveness of MHD topped steam power plants for baseload utility applications. To realize these advantages, a three-phase development program was initiated. In the first phase, the engineering data and experience were developed for the design and construction of a pilot plant, the Engineering Test Facility (ETF). Results of the ETF studies are reviewed. These three parallel independent studies were conducted by industrial teams led by the AVCO Everett Research Laboratory, the General Electric Corporation, and the Westinghouse Corporation. A preliminary analysis and the status of the critical evaluation of these results are presented.

  18. Ecosystem specific dose conversion factors for Aberg, Beberg and Ceberg

    International Nuclear Information System (INIS)

    Nordlinder, S.; Bergstroem, U.; Mathiasson, Lena

    1999-12-01

    The aim of this study was to calculate ecosystem specific dose conversion factors (EDFs) for three hypothetical sites, Aberg, Beberg and Ceberg, used in the safety analysis SR 97. The EDFs can, in combination with calculated releases of radionuclides from the geosphere, be used to illustrate relative differences in doses to the most exposed individual due to accidental leakage of radionuclides from a deep repository for spent nuclear fuel. Maps of the three sites were studied and subdivided into areas, which were characterised according to an earlier developed module system. For each of the identified modules, ecosystem transport and exposure model calculations were performed for release of 1 Bq per year during 10 000 years. 44 radionuclides contained within a deep repository for spent nuclear fuel were considered. A preliminary comparison of the EDFs for the three sites showed that the highest relative doses can be expected in Ceberg due to the high frequency of peat bog modules

  19. A preliminary neutron crystallographic study of thaumatin

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Susana C. M. [ILL-EMBL Deuteration Laboratory, Partnership for Structural Biology, 6 Rue Jules Horowitz, 38042 Grenoble (France); Institut Laue Langevin, 6 Rue Jules Horowitz, 38042 Grenoble (France); EPSAM and ISTM, Keele University, Staffordshire ST5 5BG (United Kingdom); Blakeley, Matthew P. [Institut Laue Langevin, 6 Rue Jules Horowitz, 38042 Grenoble (France); Leal, Ricardo M. F. [ILL-EMBL Deuteration Laboratory, Partnership for Structural Biology, 6 Rue Jules Horowitz, 38042 Grenoble (France); Institut Laue Langevin, 6 Rue Jules Horowitz, 38042 Grenoble (France); EPSAM and ISTM, Keele University, Staffordshire ST5 5BG (United Kingdom); ESRF, 6 Rue Jules Horowitz, BP-220, 38043 Grenoble (France); Mitchell, Edward P. [EPSAM and ISTM, Keele University, Staffordshire ST5 5BG (United Kingdom); ESRF, 6 Rue Jules Horowitz, BP-220, 38043 Grenoble (France); Forsyth, V. Trevor, E-mail: tforsyth@ill.fr [ILL-EMBL Deuteration Laboratory, Partnership for Structural Biology, 6 Rue Jules Horowitz, 38042 Grenoble (France); Institut Laue Langevin, 6 Rue Jules Horowitz, 38042 Grenoble (France); EPSAM and ISTM, Keele University, Staffordshire ST5 5BG (United Kingdom)

    2008-05-01

    Preliminary neutron crystallographic data from the sweet protein thaumatin have been recorded using the LADI-III diffractometer at the Institut Laue Langevin (ILL). The results illustrate the feasibility of a full neutron structural analysis aimed at further understanding the molecular basis of the perception of sweet taste. Such an analysis will exploit the use of perdeuterated thaumatin. A preliminary neutron crystallographic study of the sweet protein thaumatin is presented. Large hydrogenated crystals were prepared in deuterated crystallization buffer using the gel-acupuncture method. Data were collected to a resolution of 2 Å on the LADI-III diffractometer at the Institut Laue Langevin (ILL). The results demonstrate the feasibility of a full neutron crystallographic analysis of this structure aimed at providing relevant information on the location of H atoms, the distribution of charge on the protein surface and localized water in the structure. This information will be of interest for understanding the specificity of thaumatin–receptor interactions and will contribute to further understanding of the molecular mechanisms underlying the perception of taste.

  20. Low dose epidemiologic studies

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    In this chapter the BEIR committee has reviewed low-dose irradiation studies since the BEIR III report. They have considered the carcinogenic effectiveness of low-LET in populations exposed to radiation from a number of different sources: diagnostic radiography; fallout from nuclear weapons testing; nuclear installations; radiation in the workplace and high levels of natural background radiation

  1. MALLARD REPRODUCTIVE TESTING IN A POND ENVIRONMENT: A PRELIMINARY STUDY

    Science.gov (United States)

    A 2-year preliminary study was conducted on mallard ducks to determine the feasibility of using outdoor pond enclosures for reproductive studies and to evaluate the effects of the insecticide chlorpyrifos on mallard reproduction. No significant reproductive effects were observed ...

  2. Literature and data review for the surface-water pathway: Columbia River and adjacent coastal areas. Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    Walters, W.H.; Dirkes, R.L.; Napier, B.A.

    1992-11-01

    As part of the Hanford Environmental Dose Reconstruction (HEDR) Project, Battelle, Pacific Northwest Laboratories reviewed literature and data on radionuclide concentrations and distribution in the water, sediment, and biota of the Columbia River and adjacent coastal areas. Over 600 documents were reviewed including Hanford reports, reports by offsite agencies, journal articles, and graduate theses. Radionuclide concentration data were used in preliminary estimates of individual dose for the period 1964 through 1966. This report summarizes the literature and database reviews and the results of the preliminary dose estimates.

  3. Fluorouracil and high-dose leucovorin with radiotherapy as adjuvant therapy for rectal cancer. Results of a phase II study

    Energy Technology Data Exchange (ETDEWEB)

    Giralt, J. [Radiation Oncology Service, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Rubio, D. [Medical Oncology Service, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Maldonado, X. [Radiation Oncology Service, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Naval, J. [Dept. of Surgery, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Casado, S. [Medical Oncology Service, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Lara, F. [Dept. of Surgery, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Rosello, J.M. [Dept. of Preventive Medicine, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Armengol, M. [Dept. of Surgery, Hospital General Universitari Vall d`Hebron, Barcelona (Spain)

    1997-07-01

    The purpose of this phase II study was to evaluate the efficacy and toxicity of fluorouracil and high-dose leucovorin (5-FU/LV) with pelvic irradiation as adjuvant therapy for patients with macroscopical resected rectal or recto-sigmoid cancer. Following surgery for stages II-III primary (52) or recurrent rectal cancer (4), 56 patients received 8 cycles of 5-FU/LV and pelvic irradiation. 5-FU doses were 200 mgr/m{sup 2} for cycles 2-3 and 300 mgr/m{sup 2} for cycles 1 and 4-8. LV doses remained fixed at 200 mgr/m{sup 2}. Pelvic radiation was started in the third week, between the first and second cycle. The total dose was 50.4 Gy. No serve complications had been recorded. The incidence of grade 3 diarrhea was 19%. Three patients presented leukopenia grade 3 (5%). In 44 patients (78%) the planned treatment could be administered. The median follow-up was 40 months (range 22-66). Seven patients had a local relapse (13%) and 6 developed distant metastasis (10%). The 3-year disease-free survival was 72% and the overall survival was 76%. These preliminary results show that combined post-operative 5-FU/LV and pelvic radiotherapy are well tolerated and present a reasonable local control and survival rates. This adjuvant treatment should be evaluated in randomized trials. (orig.).

  4. Absorbed dose thresholds and absorbed dose rate limitations for studies of electron radiation effects on polyetherimides

    Science.gov (United States)

    Long, Edward R., Jr.; Long, Sheila Ann T.; Gray, Stephanie L.; Collins, William D.

    1989-01-01

    The threshold values of total absorbed dose for causing changes in tensile properties of a polyetherimide film and the limitations of the absorbed dose rate for accelerated-exposure evaluation of the effects of electron radiation in geosynchronous orbit were studied. Total absorbed doses from 1 kGy to 100 MGy and absorbed dose rates from 0.01 MGy/hr to 100 MGy/hr were investigated, where 1 Gy equals 100 rads. Total doses less than 2.5 MGy did not significantly change the tensile properties of the film whereas doses higher than 2.5 MGy significantly reduced elongation-to-failure. There was no measurable effect of the dose rate on the tensile properties for accelerated electron exposures.

  5. A Pilot Study on Single-dose Toxicity Testing of Scolopendrid Pharmacopuncture in Sprague-Dawley Rats

    Directory of Open Access Journals (Sweden)

    Ilhong Son

    2014-06-01

    Full Text Available Objectives:This study was performed to analyze single dose toxicity and the lethal dose of Scolopendrid Pharmacopuncture in rats. Methods:All experiments were conducted at the Korea Testing & Research Institute (KTR, an institution authorized to perform non-clinical studies, under the regulations of Good Laboratory Practice (GLP. Sprague-Dawley rats were chosen for the pilot study. Doses of Scolopendrid pharmacopuncture, 0.1, 0.5, and 1.0 mL, were administered to the experimental group, and 1.0 mL doses of normal saline solution were administered to the control group. This study was conducted under the approval of the Institutional Animal Ethic Committee. Results:No deaths or abnormalities occurred in any of the groups. No significant changes in the weight, hematological parameters or clinical chemistry were noted between the control group and the experimental group. To check for abnormalities in organs and tissues, we used microscopy to examine representative histological sections of each specified organ; the results showed no significant differences in any of the organs or tissues. Conclusion:The above findings suggest Scolopendrid Pharmacopuncture is a relatively safe to use for treatment. Further studies on the subject should be conducted to yield more concrete evidence.

  6. The preliminary study of setup errors' impact on dose distribution of image guide radiation therapy for head and neck cancer

    International Nuclear Information System (INIS)

    Xu Luying; Pan Jianji; Wang Xiaoliang; Bai Penggang; Li Qixin; Fei Zhaodong; Chen Chuanben; Ma Liqin; Tang Tianlan

    2011-01-01

    Objective: To measure the set-up errors of patients with head and neck (H and N) cancer during the image guided intensity-modulated radiotherapy (IMRT) treatment and analyze the impact of setup errors on dose distribution; then to further investigate the necessity of adjustment online for H and N cancer during IMRT treatment. Methods: Cone-beam CT (CBCT) scanning of thirty patients with H and N cancer were acquired by once weekly with a total of 6 times during IMRT treatment. The CBCT images and the original planning CT images were matched by the bony structure and worked out the translational errors of the x, y, z axis, as well as rotational errors. The dose distributions were recalculated based on the data of each setup error. The dose of planning target volume (PTV) and organs at risk were calculated in the re-planning, and than compared with the original plan by paired t-test. Results: The mean value of x, y, z axis translational set-up errors were (1.06 ± 0.95)mm, (0.95 ± 0.77)mm and (1.31 ± 1.07)mm, respectively. The rotational error of x, y, z axis were (1.04 ±0.791), (1.06 ±0.89) and (0.81 ±0.61 ), respectively. PTV 95% volume dose (D 95 ) and PTV minimal dose of re-planning for 6 times set-up were lower than original plan (6526.6 cGy : 6630.3 cGy, t =3.98, P =0.000 and 5632.6 cGy : 5792.5 cGy, t =- 2.89, P =0.007). Brain stem received 45 Gydose volume (V 45 ) and 1% brain stem volume dose (D 01 )were higher than original plan (3.54% : 2.75%, t =3.84, P =0.001 and 5129.7 cGy : 4919.3 cGy, t =4.36, P =0.000). Conclusions: The set-up errors led to the dose of PTV D 95 obviously insufficient and significantly increased V 45 , D 01 of the brainstem. So, adjustment online is necessary for H and N cancer during IMRT treatment. (authors)

  7. Does Cervical Interlaminar Epidural Steroid Injection with Low-Dose Lidocaine Cause Objective Upper Extremity Weakness? A Preliminary Study.

    Science.gov (United States)

    McCormick, Zachary L; Nelson, Ariana; Kendall, Mark C; McCarthy, Robert J; Nagpal, Geeta; Walega, David R

    2017-12-01

    Low-dose local anesthetic is often used in cervical interlaminar epidural steroid injections (CIESI), yet its effect on upper extremity strength has not been studied. The presence of consequent weakness has potential implications for postprocedure safety. This study aimed to determine whether low-dose lidocaine in a C7-T1 CIESI causes objective weakness. Prospective case series. Academic pain center. Adults, cervical radicular pain. Participants underwent CIESI with 1 mL of 1% lidocaine (3 mL total injectate). Elbow flexion (EF), wrist extension (WE), elbow extension (EE), and handgrip strength were measured by dynamometry at baseline, 15 minutes, and 30 minutes postinjection. Changes in strength from baseline and the proportion of participants with a minimum perceptible change in EF, WE, EE, and handgrip strength (≥20%) and 95% confidence intervals (CIs) were calculated. Twenty-seven participants were included. At 15 and 30 minutes postinjection, there was no within-participant difference in EF, WE, EE, and handgrip strength from baseline overall. Nonetheless, five (19%, 95% CI = 4-33) of the participants demonstrated a 20% or greater strength decrease in at least one myotomal distribution. A 20% or greater decrease in strength was present in left EF 4% (95% CI = 0-11%), right EF 7% (95% CI = 0-17%), left WE 4% (95% CI = 0-11%), and right WE 7% (95% CI = 0-17%). The present data suggest that CIESI with an injectate volume of 3 mL that includes 1 mL of 1% lidocaine may result in objective upper extremity weakness that is above the minimum threshold of perception in a subset of patients. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  8. Topics on study of low dose-effect relationship

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Takeshi [Toho Univ., School of Medicine, Tokyo (Japan); Ohyama, Harumi

    1999-09-01

    It is not exceptional but usually observed that a dose-effect relationship in biosystem is not linear. Sometimes, the low dose-effect relationship appears entirely contrary to the expectation from high dose-effect. This is called a 'hormesis' phenomena. A high dose irradiation inflicts certainly an injury on biosystem. No matter how low the dose may be, an irradiation might inflict some injury on biosystem according to Linear Non-Threshold hypothesis(LNT). On the contrary to the expectation, a low dose irradiation stimulates immune system, and promotes cell proliferation. This is called 'radiation hormesis'. The studies of the radiation hormesis are made on from four points of view as follows: (1) radiation adaptive response, (2) revitalization caused by a low dose stimulation, (3) a low dose response unexpected from the LNT hypothesis, (4) negation of the LNT hypothesis. The various empirical proofs of radiation hormesis are introduced in the report. (M . Suetake)

  9. Topics on study of low dose-effect relationship

    International Nuclear Information System (INIS)

    Yamada, Takeshi; Ohyama, Harumi

    1999-01-01

    It is not exceptional but usually observed that a dose-effect relationship in biosystem is not linear. Sometimes, the low dose-effect relationship appears entirely contrary to the expectation from high dose-effect. This is called a 'hormesis' phenomena. A high dose irradiation inflicts certainly an injury on biosystem. No matter how low the dose may be, an irradiation might inflict some injury on biosystem according to Linear Non-Threshold hypothesis(LNT). On the contrary to the expectation, a low dose irradiation stimulates immune system, and promotes cell proliferation. This is called 'radiation hormesis'. The studies of the radiation hormesis are made on from four points of view as follows: (1) radiation adaptive response, (2) revitalization caused by a low dose stimulation, (3) a low dose response unexpected from the LNT hypothesis, (4) negation of the LNT hypothesis. The various empirical proofs of radiation hormesis are introduced in the report. (M . Suetake)

  10. A New Silver Complex with Ofloxacin – Preliminary Study

    Directory of Open Access Journals (Sweden)

    Rusu Aura

    2016-06-01

    Full Text Available Objective: Silver complexes of antibacterial quinolones have the potential advantage of combining the antibacterial activity of silver and fluoroquinolones. The objective of our study was the preparation and the preliminary physico-chemical characterization of a silver complex with ofloxacin.

  11. Radiation doses to children during modified barium swallow studies

    International Nuclear Information System (INIS)

    Weir, Kelly A.; McMahon, Sandra M.; Long, Gillian; Bunch, Judith A.; Pandeya, Nirmala; Coakley, Kerry S.; Chang, Anne B.

    2007-01-01

    There are minimal data on radiation doses to infants and children undergoing a modified barium swallow (MBS) study. To document screening times, dose area product (DAP) and effective doses to children undergoing MBS and to determine factors associated with increased screening times and effective dose. Fluoroscopic data (screening time, DAP, kVp) for 90 consecutive MBS studies using pulse fluoroscopy were prospectively recorded; effective dose was calculated and data were analyzed for effects of behavior, number of swallow presentations, swallowing dysfunction and medical problems. Mean effective dose for the entire group was 0.0826 ± 0.0544 mSv, screening time 2.48 ± 0.81 min, and DAP 28.79 ± 41.72 cGy cm 2 . Significant differences were found across three age groups (≤1.0, >1.0-3.0 and >3.0 years) for effective dose (mean 0.1188, 0.0651 and 0.0529 mSv, respectively; P < 0.001), but not for screening time or DAP. Effective dose was correlated with screening time (P 0.007), DAP (P < 0.001), number of swallow presentations (P = 0.007), lower age (P = 0.017), female gender (P = 0.004), and height (P < 0.001). Screening time was correlated with total number of swallow presentations (P < 0.001) and DAP (P < 0.001). Screening times, DAP, effective dose, and child and procedural factors associated with higher effective doses are presented for children undergoing MBS studies. (orig.)

  12. Preliminary investigation of the NMR, optical and x-ray CT dose-response of polymer gel dosimeters incorporating cosolvents to improve dose sensitivity

    International Nuclear Information System (INIS)

    Koeva, V I; McAuley, K B; Olding, T; Jirasek, A; Schreiner, L J

    2009-01-01

    This study reports on efforts to increase the dose sensitivity of polymer gel dosimeters used in 3D radiation dosimetry. The potential of several different cosolvents is investigated, with the aim of increasing the solubility of N,N'-methylene-bisacrylamide crosslinker in polymer gel dosimeters. Glycerol and isopropanol increase the limit for the crosslinker solubility from approximately 3% to 5% and 10% by weight, respectively. This enables the manufacture of polymer gel dosimeters with much higher levels of crosslinking than was previously possible. New dosimeter recipes containing up to 5 wt% N,N'-methylene-bisacrylamide were subjected to spatially uniform radiation and were studied using nuclear magnetic resonance (NMR), as well as x-ray and optical CT techniques. The resulting dosimeters exhibit dose sensitivities that are up to 2.7 times higher than measured for a typical dosimeters with 3% N,N'-methylene-bisacrylamide without the addition of cosolvent. Two additional cosolvents (n-propanol and sec-butanol) were deemed unsuitable for practical dosimeters due to incompatibility with gelatin, cloudiness prior to irradiation, and immiscibility with water when large quantities of cosolvent were used. The dosimeters with high N,N'-methylene-bisacrylamide content that used isopropanol or glycerol as cosolvents had high optical clarity prior to irradiation, but did not produce suitable optical CT results for non-uniformly irradiated gels due to polymer development outside of the high dose regions of the pencil beams and significant light scatter. Further experiments are required to determine whether cosolvents can be used to manufacture gels with sufficiently high dose sensitivity for readout using x-ray computed tomography.

  13. Low-Dose Aspirin Reduces Breast Cancer Risk in Women with Diabetes: A Nationwide Retrospective Cohort Study in Taiwan.

    Science.gov (United States)

    Yang, Yi-Sun; Kornelius, Edy; Chiou, Jeng-Yuan; Lai, Yung-Rung; Lo, Shih-Chang; Peng, Chiung-Huei; Huang, Chien-Ning

    2017-12-01

    Low-dose aspirin is commonly used for preventing cardiovascular disease in people with diabetes, but its association with cancer remains controversial. This study used a nationwide population-based reimbursement database to investigate the relationship between low-dose aspirin use and breast cancer incidence in women with diabetes. This retrospective cohort study was conducted using data retrieved from the National Health Insurance Research Database in Taiwan from January 1, 1998 to December 31, 2011. Women diagnosed as having diabetes with low-dose aspirin use (75-165 mg daily) were identified as the study population, whereas those without low-dose aspirin use were selected as the comparison group. We analyzed 148,739 patients with diabetes. Their mean age (standard deviation) was 63.3 (12.8) years. A total of 27,378 patients were taking aspirin. Overall, the use of aspirin in patients with diabetes reduced the risk of breast cancer by 18% (hazard ratio [HR], 0.82; 95% confidence interval [CI], 0.71-0.94) after adjustment for potential confounders, namely age and comorbidities. Specifically, a cumulative dose of aspirin exceeding 88,900 mg was observed to reduce the risk of breast cancer by 47% (HR, 0.53, 95% CI, 0.43-0.67); however, low (aspirin did not reduce the risk of breast cancer. Our findings suggest that a cumulative aspirin dosage of more than 88,900 mg daily was associated with a reduced risk of breast cancer in women with diabetes. However, additional studies are necessary to confirm these findings.

  14. IRISS '98: The Intranet as a Learning Tool: A Preliminary Study

    Directory of Open Access Journals (Sweden)

    K. J. Garland

    1998-01-01

    Full Text Available Using the World Wide Web (WWW as an interactive educative tool is still a relatively new concept, and little is known of its impact on learning when it is used as a dynamic learning tool. Despite this the use of educational internet sites, in the form of virtual classrooms and courses, appears to be increasing rapidly. Thus, it is important that their ability to facilitate learning is evaluated. We present the findings of a preliminary study which examined the amount, type and quality of leaning of an undergraduate indroductory history course when presented to three different groups of participants. All participants received four regularly spaced 30 minute study and repeated test sessions over an eight day period. A final test of new questions was also administered at the end of the study. Results showed that the amount of historical knowledge acquired by the end of the study was greatest for those paticpants who learnt using traditional methods, and that over the four test sessions this group consistently outperformed both computer groups. Moreover, the way in which knowledge was acquired was qualitatively different in the groups with the traditional group exhibiting more 'Know' responses while the Intranet group exhibited more 'Remember' responses. Finally, using useability questionnaires, we found that participants preferred learning via traditional methods to screen and Intranet presentations, and that participants who had learnt using computers felt that their learning experience had suffered. These findings have important implications for educators, and others who wish to use the Internet as a training tool, and we discuss our findings through the evaluation of the different presentational media used, specific Intranet design criteria and general usability factors, which, we suggest, are of paramount importance.

  15. Radiation shielding aspects for long manned mission to space - Criteria, survey study and preliminary model

    International Nuclear Information System (INIS)

    Sztejnberg, M.; Xiao, S.; Satvat, N.; Limon, F.; Hopkins, J.; Jevremovic, T.; T. Jevremovic)

    2006-01-01

    The prospect of manned space missions out side Earth's or bit is limited by the travel time and shielding against cosmic radiation. The chemical rockets currently used in the space program have no hope of propelling a manned vehicle to a far away location such as Mars due to the enormous mass of fuel that would be required. The specific energy available from nuclear fuel is a factor of 106 higher than chemical fuel; it is there fore obvious that nuclear power production in space is a must. On the other hand, recent considerations to send a man to the Moon for a long stay would require a stable, secured, and safe source of energy (there is hardly anything beyond nuclear power that would provide a useful and reliably safe sustainable supply of energy). National Aeronautics and Space Administration (NASA) anticipates that the mass of a shielding material required for long travel to Mars is the next major design driver. In 2006 NASA identified a need to assess and evaluate potential gaps in existing knowledge and understanding of the level and types of radiation critical to astronauts' health during the long travel to Mars and to start a comprehensive study related to the shielding design of a spacecraft finding the conditions for the mitigation of radiation components contributing to the doses beyond accepted limits. In order to reduce the overall space craft mass, NASA is looking for the novel, multi-purpose and multi-functional materials that will provide effective shielding of the crew and electronics on board. The Laboratory for Neutronics and Geometry Computation in the School of Nuclear Engineering at Purdue University led by Prof. Tatjana Jevremovic began in 2004 the analytical evaluations of different lightweight materials. The preliminary results of the design survey study are presented in this paper. (author)

  16. Radiation shielding aspects for long manned mission to space: Criteria, survey study, and preliminary model

    Directory of Open Access Journals (Sweden)

    Sztejnberg Manuel

    2006-01-01

    Full Text Available The prospect of manned space missions outside Earth's orbit is limited by the travel time and shielding against cosmic radiation. The chemical rockets currently used in the space program have no hope of propelling a manned vehicle to a far away location such as Mars due to the enormous mass of fuel that would be required. The specific energy available from nuclear fuel is a factor of 106 higher than chemical fuel; it is therefore obvious that nuclear power production in space is a must. On the other hand, recent considerations to send a man to the Moon for a long stay would require a stable, secured and safe source of energy (there is hardly anything beyond nuclear power that would provide a useful and reliably safe sustainable supply of energy. National Aeronautics and Space Administration (NASA anticipates that the mass of a shielding material required for long travel to Mars is the next major design driver. In 2006 NASA identified a need to assess and evaluate potential gaps in existing knowledge and understanding of the level and types of radiation critical to astronauts' health during the long travel to Mars and to start a comprehensive study related to the shielding design of a spacecraft finding the conditions for the mitigation of radiation components contributing to the doses beyond accepted limits. In order to reduce the overall space craft mass, NASA is looking for the novel, multi-purpose and multi-functional materials that will provide effective shielding of the crew and electronics on board. The Laboratory for Neutronics and Geometry Computation in the School of Nuclear Engineering at Purdue University led by Prof. Tatjana Jevremović began in 2004 the analytical evaluations of different lightweight materials. The preliminary results of the design survey study are presented in this paper.

  17. Simulation studies on a prototype ionization chamber for measurement of personal dose equivalent, Hp(10)

    International Nuclear Information System (INIS)

    Cardoso, J.; Oliveira, C.; Carvalho, A.F.

    2005-01-01

    Full text: The Metrological Laboratory of lonizing Radiation and Radioactivity (LMRIR) of Nuclear and Technological Institute (ITN) has designed and constructed a prototype ionization chamber for direct measurement of the personal dose equivalent, H p (10), similar to the developed by the Physikalisch-Technische Bundesanstalt (PTB) and now commercialized by PTW. Tests already performed had shown that the behaviour of this chamber is very close to the PTB chamber, namely the energy dependence for the x-ray radiation qualities of the ISO 4037-1 narrow series N-30, N-40, N-60, N-80, N-100 and N-120 and also for gamma radiation of 137 Cs and 60 Co. However, the results obtained also show a high dependence on the energy for some incident radiation angles and a low magnitude of the electrical response of the ionization chamber. In order to try to optimize the performance of the chamber, namely to decrease the energy dependence and to improve the magnitude of the electrical response of the ionization chamber, the LMRIR initiated numerical simulation of this ionization chamber using a Monte-Carlo method for simulation of radiation transport using, in a first step, the MCNPX code. So, simulation studies of some physical parameters are been performed in order to optimize the response of the ionization chamber, namely the diameter of the central electrode of the ionization chamber, the thickness of the front wall of the ionization chamber, among others. Preliminary results show that probably the actual geometry of the ionization chamber is not yet the optimized configuration. The simulation study will carry on in order to find the optimum geometry. (author)

  18. Sources of variability in OSL dose measurements using single grains of quartz

    International Nuclear Information System (INIS)

    Thomsen, K.J.; Murray, A.S.; Boetter-Jensen, L.

    2005-01-01

    In luminescence-based measurements of dose distributions in unheated mineral samples, the observed spread in dose values is usually attributed to four main factors: fluctuations in the number of photons counted, incomplete zeroing of any prior trapped charge (including signals arising from thermal transfer), heterogeneity in dosimetry, and instrument reproducibility. For correct interpretation of measured dose distributions in retrospective dosimetry, it is important to understand the relative importance of these components, and to establish whether other factors also contribute to the observed spread. In this preliminary study, dose distributions have been studied using single grains of heated and laboratory irradiated quartz. By heating the sample, the contribution from incomplete zeroing was excluded and at the same time the sample was sensitised. The laboratory gamma irradiation was designed to deliver a uniform dose to the sample. Thus it was anticipated that statistical fluctuations in the number of photons counted and instrument reproducibility, both quantifiable entities, should be able to account for all the observed variance in the measured dose distributions. We examine this assumption in detail, and discuss the origins and importance of the residual variance in our data

  19. Limiting CT radiation dose in children with craniosynostosis: phantom study using model-based iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Kaasalainen, Touko; Lampinen, Anniina [University of Helsinki and Helsinki University Hospital, HUS Medical Imaging Center, Radiology, POB 340, Helsinki (Finland); University of Helsinki, Department of Physics, Helsinki (Finland); Palmu, Kirsi [University of Helsinki and Helsinki University Hospital, HUS Medical Imaging Center, Radiology, POB 340, Helsinki (Finland); School of Science, Aalto University, Department of Biomedical Engineering and Computational Science, Helsinki (Finland); Reijonen, Vappu; Kortesniemi, Mika [University of Helsinki and Helsinki University Hospital, HUS Medical Imaging Center, Radiology, POB 340, Helsinki (Finland); Leikola, Junnu [University of Helsinki and Helsinki University Hospital, Department of Plastic Surgery, Helsinki (Finland); Kivisaari, Riku [University of Helsinki and Helsinki University Hospital, Department of Neurosurgery, Helsinki (Finland)

    2015-09-15

    Medical professionals need to exercise particular caution when developing CT scanning protocols for children who require multiple CT studies, such as those with craniosynostosis. To evaluate the utility of ultra-low-dose CT protocols with model-based iterative reconstruction techniques for craniosynostosis imaging. We scanned two pediatric anthropomorphic phantoms with a 64-slice CT scanner using different low-dose protocols for craniosynostosis. We measured organ doses in the head region with metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters. Numerical simulations served to estimate organ and effective doses. We objectively and subjectively evaluated the quality of images produced by adaptive statistical iterative reconstruction (ASiR) 30%, ASiR 50% and Veo (all by GE Healthcare, Waukesha, WI). Image noise and contrast were determined for different tissues. Mean organ dose with the newborn phantom was decreased up to 83% compared to the routine protocol when using ultra-low-dose scanning settings. Similarly, for the 5-year phantom the greatest radiation dose reduction was 88%. The numerical simulations supported the findings with MOSFET measurements. The image quality remained adequate with Veo reconstruction, even at the lowest dose level. Craniosynostosis CT with model-based iterative reconstruction could be performed with a 20-μSv effective dose, corresponding to the radiation exposure of plain skull radiography, without compromising required image quality. (orig.)

  20. Gratitude, abstinence, and alcohol use disorders: Report of a preliminary finding.

    Science.gov (United States)

    Krentzman, Amy R

    2017-07-01

    Gratitude is a central component of addiction recovery for many, yet it has received scant attention in addiction research. In a sample of 67 individuals entering abstinence-based alcohol-use-disorder treatment, this study employed gratitude and abstinence variables from sequential assessments (baseline, 6months, 12months) to model theorized causal relationships: gratitude would increase pre-post treatment and gratitude after treatment would predict greater percent days abstinent 6months later. Neither hypothesis was supported. This unexpected result led to the theory that gratitude for sobriety was the construct of interest; therefore, the association between gratitude and future abstinence would be positive among those already abstinent. Thus, post-treatment abstinence was tested as a moderator of the effect of gratitude on future abstinence: this effect was statistically significant. For those who were abstinent after treatment, the relationship between gratitude and future abstinence was positive; for those drinking most frequently after treatment, the relationship between gratitude and future abstinence was negative. In this preliminary study, dispositional tendency to affirm that there is much to be thankful for appeared to perpetuate the status quo-frequent drinkers with high gratitude were drinking frequently 6months later; abstinent individuals with high gratitude were abstinent 6months later. Gratitude exercises might be contraindicated for clients who are drinking frequently and have abstinence as their treatment goal. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Development and preliminary experimental study on micro-stacked insulator

    International Nuclear Information System (INIS)

    Ren Chengyan; Yuan Weiqun; Zhang Dongdong; Yan Ping; Wang Jue

    2009-01-01

    High gradient insulating technology is one of the key technologies in new type dielectric wall accelerator(DWA). High gradient insulator, namely micro-stacked insulator, was developed and preliminary experimental study was done. Based on the finite element and particle simulating method, surface electric field distribution and electron movement track of micro-stacked insulator were numerated, and then the optimized design proposal was put forward. Using high temperature laminated method, we developed micro-stacked insulator samples which uses exhaustive fluorinated ethylene propylene(FEP) as dielectric layer and stainless steel as metal layer. Preliminary experiment of vacuum surface flashover in nanosecond pulse voltage was done and micro-stacked insulator exhibited favorable vacuum surface flashover performance with flashover field strength of near 180 kV/cm. (authors)

  2. Preliminary measurements of gamma radiation in Chilean Antarctic Stations

    International Nuclear Information System (INIS)

    Stuardo B, E.

    1983-01-01

    Natural and artificial gamma radiation, 1 m above the soil, is being investigated in 4 Chilean Antartic Stations. The measurements are performed with different types of TLD detectors. Preliminary results in the Tte. Marsh Station are reported and discussed. An average exposition of 3,5 μR/h was found during a 108 days period. This exposition corresponds to an annual dose of about 40 mrad, 8% of the annual dose limit for individual of the public. The presence of low energy artificial radioisotopes was not found. (Author)

  3. Brain responses to biological motion predict treatment outcome in young adults with autism receiving Virtual Reality Social Cognition Training: Preliminary findings.

    Science.gov (United States)

    Yang, Y J Daniel; Allen, Tandra; Abdullahi, Sebiha M; Pelphrey, Kevin A; Volkmar, Fred R; Chapman, Sandra B

    2017-06-01

    Autism Spectrum Disorder (ASD) is characterized by remarkable heterogeneity in social, communication, and behavioral deficits, creating a major barrier in identifying effective treatments for a given individual with ASD. To facilitate precision medicine in ASD, we utilized a well-validated biological motion neuroimaging task to identify pretreatment biomarkers that can accurately forecast the response to an evidence-based behavioral treatment, Virtual Reality-Social Cognition Training (VR-SCT). In a preliminary sample of 17 young adults with high-functioning ASD, we identified neural predictors of change in emotion recognition after VR-SCT. The predictors were characterized by the pretreatment brain activations to biological vs. scrambled motion in the neural circuits that support (a) language comprehension and interpretation of incongruent auditory emotions and prosody, and (b) processing socio-emotional experience and interpersonal affective information, as well as emotional regulation. The predictive value of the findings for individual adults with ASD was supported by regression-based multivariate pattern analyses with cross validation. To our knowledge, this is the first pilot study that shows neuroimaging-based predictive biomarkers for treatment effectiveness in adults with ASD. The findings have potentially far-reaching implications for developing more precise and effective treatments for ASD. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Preliminary study on electron paramagnetic resonance (EPR) signal properties of mobile phone components for dose estimation in radiation accident

    Energy Technology Data Exchange (ETDEWEB)

    Park, Byeong Ryong; Ha, Wi Ho; Park, Sun Hoo; Lee, Jin Kyeong; Lee, Seung Sook [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2015-12-15

    We have investigated the EPR signal properties in 12 components of two mobile phones (LCD, OLED) using electron paramagnetic resonance (EPR) spectrometer in this study.EPR measurements were performed at normal atmospheric conditions using Bruker EXEXSYS-II E500 spectrometer with X-band bridge, and samples were irradiated by {sup 137}C{sub s} gamma-ray source. To identify the presence of radiation-induced signal (RIS), the EPR spectra of each sample were measured unirradiated and irradiated at 50 Gy. Then, dose-response curve and signal intensity variating by time after irradiation were measured. As a result, the signal intensity increased after irradiation in all samples except the USIM plastic and IC chip. Among the samples, cover glass(CG), lens, light guide plate(LGP) and diffusion sheet have shown fine linearity (R{sup 2} > 0.99). Especially, the LGP had ideal characteristics for dosimetry because there were no signal in 0 Gy and high rate of increase in RIS. However, this sample showed weakness in fading. Signal intensity of LGP and Diffusion Sheet decreased by 50% within 72 hours after irradiation, while signals of Cover Glass and Lens were stably preserved during the short period of time. In order to apply rapidly EPR dosimetry using mobile phone components in large-scale radiation accidents, further studies on signal differences for same components of the different mobile phone, fading, pretreatment of samples and processing of background signal are needed. However, it will be possible to do dosimetry by dose-additive method or comparative method using unirradiated same product in small-scale accident.

  5. Histo-morphological findings and preliminary clinical findings after pre-operative short-term irradiation of squamous cell carcinomas of the floor of the mouth using telecobalt sources

    International Nuclear Information System (INIS)

    Dieckmann, J.; Morgenroth, K.; Hering, K.; Will, C.

    1981-01-01

    In a clinical investigation, the preoperative short-term telecobalt irradiation of patients with carcinoma of the floor of the mouth was tested. On 50 patients, the preoperative irradiation was applied after identifying the tumour by PE and fast cesion examination. Within 3 days, a focal dose of 15 to 20 Gy was applied. On the 4th day, the radical operation took place. 2-3 weeks after the operation, the saturation irradiation was carried out. For the purpose of testing, 100 patients under our usual combined treatment with radical operation plus postoperative curative telecobalt irradiation were refined to. The tissue sample before irradiation was histologically compared to the preoperatively irradiated tumour. The examinations revealed definitively a letal damage of the tumour cells. Up to the moment, the clinical results could not be received statistically because the investigation had just been finished when the draft of the speech was in preparation. But we can state, as a preliminary result, that there is a trend recognizable in which the mortality in the patients group seems to be appr. 8% lower. It is noteworthy, however, that the relapse and metastase behaviour in the group of preirradiated tumours seems to be significantly better than in the group irradiated only surgically and postoperatively: it is seen that the tumour-caused mortality in the first group is 18% less than in the latter. (orig.) [de

  6. Preliminary clinical nursing leadership competency model: a qualitative study from Thailand.

    Science.gov (United States)

    Supamanee, Treeyaphan; Krairiksh, Marisa; Singhakhumfu, Laddawan; Turale, Sue

    2011-12-01

    This qualitative study explored the clinical nursing leadership competency perspectives of Thai nurses working in a university hospital. To collect data, in-depth interviews were undertaken with 23 nurse administrators, and focus groups were used with 31 registered nurses. Data were analyzed using content analysis, and theory development was guided by the Iceberg model. Nurses' clinical leadership competencies emerged, comprising hidden characteristics and surface characteristics. The hidden characteristics composed three elements: motive (respect from the nursing and healthcare team and being secure in life), self-concept (representing positive attitudes and values), and traits (personal qualities necessary for leadership). The surface characteristics comprised specific knowledge of nurse leaders about clinical leadership, management and nursing informatics, and clinical skills, such as coordination, effective communication, problem solving, and clinical decision-making. The study findings help nursing to gain greater knowledge of the essence of clinical nursing leadership competencies, a matter critical for theory development in leadership. This study's results later led to the instigation of a training program for registered nurse leaders at the study site, and the formation of a preliminary clinical nursing leadership competency model. © 2011 Blackwell Publishing Asia Pty Ltd.

  7. Oxygenates in automotive fuels. Consequence analysis - preliminary study

    International Nuclear Information System (INIS)

    Brandberg, Aa.; Saevbark, B.

    1994-01-01

    Oxygenates is used in gasoline due to several reasons. They are added as high-octane components in unleaded gasoline and as agents to reduce the emission of harmful substances. Oxygenates produced from biomass might constitute a coming market for alternative fuels. This preliminary study describes the prerequisites and consequences of such an oxygenate utilization. 39 refs, 9 figs, 5 tabs

  8. Genetic Predictors of Fatigue in Prostate Cancer Patients Treated with Androgen Deprivation Therapy: Preliminary Findings

    Science.gov (United States)

    Jim, Heather S.L.; Park, Jong Y.; Permuth-Wey, Jennifer; Rincon, Maria A.; Phillips, Kristin M.; Small, Brent J.; Jacobsen, Paul B.

    2012-01-01

    Background Fatigue is a common and distressing side effect of androgen deprivation therapy (ADT) for prostate cancer. The goal of the current study was to examine the relationship between changes in fatigue following initiation of ADT and single nucleotide polymorphisms (SNPs) in three pro-inflammatory cytokine genes: interleukin-1 beta (IL1B), interleukin-6 (IL6), and tumor necrosis factor alpha (TNFA). Methods As part of a larger study, men with prostate cancer (n=53) were recruited prior to initiation of ADT. Fatigue was assessed at recruitment and six months after initiation of ADT. DNA was extracted from blood drawn at baseline. Results Patients with the IL6-174 (rs1800795) G/C or C/C genotype displayed greater increases in fatigue intrusiveness, frequency, and duration than the G/G genotype (p values≤0.05), although inclusion of age, race, and baseline depressive symptomatology in the model attenuated these relationships (p values≤0.09). Patients with the TNFA-308 (rs1800629) G/A genotype showed greater increases in fatigue severity than the G/G genotype (p=0.02). IL1B-511 (rs16944) genotype did not significantly predict changes in fatigue (p values>0.46). Patients with higher numbers of variants displayed greater increases in fatigue duration and interference (p values≤0.02) than patients with lower numbers of variants. Conclusions Prostate cancer patients treated with ADT who carry variant alleles of the IL6 and TNFA genes are susceptible to heightened fatigue. These preliminary data lend support for the role of genetic variation in the development of cancer-related fatigue secondary to ADT. Findings are relevant to attempts to develop personalized approaches to cancer treatment. PMID:22475653

  9. Estimation of dose and exposure at sentinel node study

    International Nuclear Information System (INIS)

    Skopljak, A.; Kucukalic-Selimovic, E.; Beslic, N.; Begic, A.; Begovic-Hadzimuratovic, S.; Drazeta, Z.; Beganovic, A.

    2005-01-01

    The purpose of this study was to estimate the dose end exposure in staff involved in sentinel node procedure for breast cancer patients. The Institute of Nuclear Medicine in Sarajevo uses a protocol for lymphoscintigraphy of the sentinel node whereby 13 MBq of 9 9mT c nanocoll are used. In this study, we measured radiation doses and exposure of a nuclear medicine physician and a technologist, as well as a surgeon performing sentinel node lymphoscintigraphy and biopsy. Dose and exposure were calculated using the equation in which we have gamma constant for 9 9mT c. Calculations were made for different times of exposure and distance. In Table 1. we estimated the dose and exposure during sentinel node study. Radiation levels were very low and the most exposed hospital staff performing sentinel node study were nuclear medicine physicians. The doses on the hands of surgeons were negligible 8 hours after exposure.(author)

  10. What do recent epidemiological studies tell us about the risk of cancer from radiation doses typical of diagnostic radiography?

    International Nuclear Information System (INIS)

    Harbron, R.W.

    2016-01-01

    The last five years have seen unprecedented efforts to gain further understanding of the cancer risks following exposure to radiation doses below 100 mGy. Research has focused on occupationally exposed groups, populations exposed to elevated background radiation levels and children undergoing computed tomography scans. This review summarises the main findings of these studies and discusses the implications for diagnostic radiography. On balance, recent studies strengthen the association between radiation exposure at diagnostic dose levels and the risk of developing cancer at low doses. Although subject to considerable uncertainties, the risks to patients and staff from exposure to X-rays at diagnostic dose levels appear to be small, but non-zero. Despite the improved statistical power of recent studies, a number of shortcomings are apparent. These include dosimetric uncertainties and the potential confounding effects of cancer pre-disposing conditions and pre-existing tumours. - Highlights: • The risk of cancer from radiation doses below around 100 mGy is uncertain. • A number of new studies have been published with reasonably high statistical power. • These studies strengthen the association between X-rays and cancer at low doses. • Large uncertainties remain, however.

  11. Preliminary investigation of the NMR, optical and x-ray CT dose-response of polymer gel dosimeters incorporating cosolvents to improve dose sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Koeva, V I; McAuley, K B [Department of Chemical Engineering, Queen' s University, Kingston, ON, K7L 3N6 (Canada); Olding, T [Department of Physics, Queen' s University, Kingston, ON, K7L 3N6 (Canada); Jirasek, A [Department of Physics and Astronomy, University of Victoria, Victoria, BC, V8W 3P6 (Canada); Schreiner, L J [Cancer Centre of Southeastern Ontario, Kingston, ON, K7L5P9 (Canada)], E-mail: kim.mcauley@chee.queensu.ca

    2009-05-07

    This study reports on efforts to increase the dose sensitivity of polymer gel dosimeters used in 3D radiation dosimetry. The potential of several different cosolvents is investigated, with the aim of increasing the solubility of N,N'-methylene-bisacrylamide crosslinker in polymer gel dosimeters. Glycerol and isopropanol increase the limit for the crosslinker solubility from approximately 3% to 5% and 10% by weight, respectively. This enables the manufacture of polymer gel dosimeters with much higher levels of crosslinking than was previously possible. New dosimeter recipes containing up to 5 wt% N,N'-methylene-bisacrylamide were subjected to spatially uniform radiation and were studied using nuclear magnetic resonance (NMR), as well as x-ray and optical CT techniques. The resulting dosimeters exhibit dose sensitivities that are up to 2.7 times higher than measured for a typical dosimeters with 3% N,N'-methylene-bisacrylamide without the addition of cosolvent. Two additional cosolvents (n-propanol and sec-butanol) were deemed unsuitable for practical dosimeters due to incompatibility with gelatin, cloudiness prior to irradiation, and immiscibility with water when large quantities of cosolvent were used. The dosimeters with high N,N'-methylene-bisacrylamide content that used isopropanol or glycerol as cosolvents had high optical clarity prior to irradiation, but did not produce suitable optical CT results for non-uniformly irradiated gels due to polymer development outside of the high dose regions of the pencil beams and significant light scatter. Further experiments are required to determine whether cosolvents can be used to manufacture gels with sufficiently high dose sensitivity for readout using x-ray computed tomography.

  12. Radiation doses from radon and progeny in Irish houses

    International Nuclear Information System (INIS)

    McLaughlin, J.P.

    1985-08-01

    In the United Kingdom, the estimated average annual effective dose equivalent to members of the public from all sources is 2.4 mSv (240 mrem). 40% of this dose is contributed by exposure to radon, and it is not unreasonable to assume that the situation in Ireland is very similar. During 1982-84 a preliminary study of radon and penetrating radiation on 300 Irish houses showed seasonally averaged indoor radon concentrations in the range 3 Bq/m 3 of air to 700 bq/m 3 , with a median value of about 40 bq/m 3 . A national survey of indoor radon has now been undertaken; 3000 households, randomly selected from the electoral register are to be monitored and the result correlated with energy conservation practices. The final part of this document deals with the regulatory aspects of radon control and reviews the practices for reduction of indoor radon daughter doses presently in hand in Scandinavia. An appendix of radiation units and terms is also given

  13. Dose reduction and optimization studies (ALARA) at nuclear power facilities

    International Nuclear Information System (INIS)

    Baum, J.W.; Meinhold, C.B.

    1983-01-01

    Brookhaven National Laboratory (BNL) has been commissioned by the Nuclear Regulatory Commission (NRC) to study dose-reduction techniques and effectiveness of as low as reasonably achievable (ALARA) planning at LWR plants. These studies have the following objectives: identify high-dose maintenance tasks; identify dose-reduction techniques; examine incentives for dose reduction; evaluate cost-effectiveness and optimization of dose-reduction techniques; and compile an ALARA handbook on data, engineering modifications, cost-effectiveness calculations, and other information of interest to ALARA practioners

  14. Searching for a strategy to gamma-sterilize Portuguese cork stoppers - preliminary studies on bioburden, radioresistance and sterility assurance level

    International Nuclear Information System (INIS)

    Botelho, M.L.; Almeida-Vara, E.; Andrade, M.E.; Tenreiro, R.

    1988-01-01

    A gamma radiation plant will start running next year in Portugal, to sterilize medical devices and wine cork stoppers. As Portugal is the first world producer, manufacturer and exporter of wine cork stoppers, an efficient sterilizing procedure is required to overcome moulding from long term shipping. Preliminary research on cork stoppers bioburden and microflora radioresistance allowed to establish reliable D 10 and Sterility Assurance Level (SAL) values. Studied samples showed an initial average contamination of about 10 4 c.f.u. per cork stopper. The determined D 10 values for fungi were not higher than 2 kGy. In these conditions, a SAL of 10 -4 can be expected when the product is treated at a minimum absorbed dose of 15 kGy. (author)

  15. Cytogenetic effect of low dose gamma-radiation in Hordeum vulgare seedlings: non-linear dose-effect relationship.

    Science.gov (United States)

    Geras'kin, Stanislav A; Oudalova, Alla A; Kim, Jin Kyu; Dikarev, Vladimir G; Dikareva, Nina S

    2007-03-01

    The induction of chromosome aberrations in Hordeum vulgare germinated seeds was studied after ionizing irradiation with doses in the range of 10-1,000 mGy. The relationship between the frequency of aberrant cells and the absorbed dose was found to be nonlinear. A dose-independent plateau in the dose range from about 50 to 500 mGy was observed, where the level of cytogenetic damage was significantly different from the spontaneous level. The comparison of the goodness of the experimental data fitting with mathematical models of different complexity, using the most common quantitative criteria, demonstrated the advantage of a piecewise linear model over linear and polynomial models in approximating the frequency of cytogenetical disturbances. The results of the study support the hypothesis of indirect mechanisms of mutagenesis induced by low doses. Fundamental and applied implications of these findings are discussed.

  16. Dose-response relationship for breast cancer induction at radiotherapy dose

    Directory of Open Access Journals (Sweden)

    Gruber Günther

    2011-06-01

    Full Text Available Abstract Purpose Cancer induction after radiation therapy is known as a severe side effect. It is therefore of interest to predict the probability of second cancer appearance for the patient to be treated including breast cancer. Materials and methods In this work a dose-response relationship for breast cancer is derived based on (i the analysis of breast cancer induction after Hodgkin's disease, (ii a cancer risk model developed for high doses including fractionation based on the linear quadratic model, and (iii the reconstruction of treatment plans for Hodgkin's patients treated with radiotherapy, (iv the breast cancer induction of the A-bomb survivor data. Results The fitted model parameters for an α/β = 3 Gy were α = 0.067Gy-1 and R = 0.62. The risk for breast cancer is according to this model for small doses consistent with the finding of the A-bomb survivors, has a maximum at doses of around 20 Gy and drops off only slightly at larger doses. The predicted EAR for breast cancer after radiotherapy of Hodgkin's disease is 11.7/10000PY which can be compared to the findings of several epidemiological studies where EAR for breast cancer varies between 10.5 and 29.4/10000PY. The model was used to predict the impact of the reduction of radiation volume on breast cancer risk. It was estimated that mantle field irradiation is associated with a 3.2-fold increased risk compared with mediastinal irradiation alone, which is in agreement with a published value of 2.7. It was also shown that the modelled age dependency of breast cancer risk is in satisfying agreement with published data. Conclusions The dose-response relationship obtained in this report can be used for the prediction of radiation induced secondary breast cancer of radiotherapy patients.

  17. Image quality, radiation dose and diagnostic accuracy of 70 kVp whole brain volumetric CT perfusion imaging: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Fang, Xiao Kun; Ni, Qian Qian; Zhou, Chang Sheng; Chen, Guo Zhong; Luo, Song; Zhang, Long Jiang; Lu, Guang Ming [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Schoepf, U.J. [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Medical University of South Carolina, Ashley River Tower, Division of Cardiovascular Imaging, Charleston, SC (United States); Fuller, Stephen R.; De Cecco, Carlo N. [Medical University of South Carolina, Ashley River Tower, Division of Cardiovascular Imaging, Charleston, SC (United States)

    2016-11-15

    To evaluate image quality and diagnostic accuracy for acute infarct detection and radiation dose of 70 kVp whole brain CT perfusion (CTP) and CT angiography (CTA) reconstructed from CTP source data. Patients were divided into three groups (n = 50 each): group A, 80 kVp, 21 scanning time points; groups B, 70 kVp, 21 scanning time points; group C, 70 kVp, 17 scanning time points. Objective and subjective image quality of CTP and CTA were compared. Diagnostic accuracy for detecting acute infarct and cerebral artery stenosis ≥ 50 % was calculated for CTP and CTA with diffusion weighted imaging and digital subtraction angiography as reference standards. Effective radiation dose was compared. There were no differences in any perfusion parameter value between three groups (P > 0.05). No difference was found in subjective image quality between three groups (P > 0.05). Diagnostic accuracy for detecting acute infarct and vascular stenosis showed no difference between three groups (P > 0.05). Compared with group A, radiation doses of groups B and C were decreased by 28 % and 37 % (both P < 0.001), respectively. Compared with 80 kVp protocol, 70 kVp brain CTP allows comparable vascular and perfusion assessment and lower radiation dose while maintaining high diagnostic accuracy in detecting acute infarct. (orig.)

  18. A graphical review of radiogenic animal cancer data using the 'dose and dose-rate map'

    International Nuclear Information System (INIS)

    Yoshida, Kazuo; Hoshi, Yuko; Sakai, Kazuo

    2008-01-01

    We have been investigating the effects of low dose or low dose rate irradiation on mice, using our low dose-rate irradiation facilities. In these studies, we found that the effects were highly dependent on both total dose and dose rate. To show this visually, we proposed the 'dose/dose rate map', and plotted the results of our laboratory and our co-workers. The map demonstrated that dose/dose rate plane could be divided into three areas; 1) An area where harmful effects are observed, 2) An area where no harmful effects are observed, and 3) Another area, between previous two areas, where certain protective functions are enhanced. As this map would be a powerful tool to find some trend among the vast numbers of data relating the biological effects of ionizing radiation, we have developed a computer program which plots the collected data on the dose/dose rate map sorting by experimental conditions. In this study, we graphically reviewed and analyzed the data relating to the lifespan studies of animals with a view to determining the relationships between doses and dose rates of ionizing radiation and cancer incidence. The data contains about 800 sets of experiments, which concerns 187,000 animals exposed to gamma ray or X-ray and their 112,000 controls, and total of about 30,000 cancers in exposed animals and 14,000 cancers in controls. About 800 points of data were plotted on the dose/dose rate map. The plot showed that 1) The divided three areas in the dose/dose rate map were generally confirmed by these 800 points of data, and 2) In some particular conditions, e.g. sarcoma by X-rays, the biologically effective area is extended to relatively high dose/dose rate area. (author)

  19. Preliminary Study of a Piston Pump for Cryogenic Fluids

    Science.gov (United States)

    Biermann, Arnold E.; Kohl, Robert C.

    1959-01-01

    Preliminary data are presented covering the performance of a low-speed, five-cylinder piston pump designed for handling boiling hydrogen. This pump was designed for a flow of 55 gallons per minute at 240 rpm with a discharge pressure of 135 pounds per square inch. Tests were made using JP-4 fuel, liquid nitrogen, and liquid hydrogen. Pump delivery and endurance characteristics were satisfactory for the range of operation covered. In connection with the foregoing pump development, the cavitation characteristics of a preliminary visual model, glass-cylinder pump and of a simple reciprocating disk were studied. Subcooling of approximately 0.60 F was obtained from the cavitation produced by reciprocating a disk in boiling nitrogen and in boiling water. The subcooling obtained in a similar manner with liquid hydrogen was somewhat less.

  20. A Preliminary Study of Sex Differences in Emotional Experience.

    Science.gov (United States)

    Reyes-Aguilar, Azalea; Barrios, Fernando A

    2016-04-01

    Evolutionary approaches have proposed that women possess an advantage over men in emotional functioning to promote attachment for child-rearing. Likewise, sex differences have been reported in traits such as personality and empathy, traits that likely modulate emotional processing. In this preliminary study, sex differences in emotional processing were analyzed, including empathy as a social emotion and personality traits, as well as whether there exist relationships between those measures. Young volunteers (N = 105) indicated the emotional valence, activation, and dominance that they experience in situations categorized as emotionally positive, negative, or neutral. The results of comparison between sexes supported the approach that women showed more sensitivity to high activation and dominance for positive emotions and empathy, and men were more sensitive to negative situations. Correlation analysis showed only one positive relationship between scores of Self-transcendence, a subscale of Temperament and Character Inventory, with activation scores of neutral situations, but not with emotionally charged situations, perhaps because emotions are context-dependent processes while personality traits are considered context-independent descriptions of habits. These findings should be replicated to enrich knowledge about problems in emotional processing. © The Author(s) 2016.

  1. Atomoxetine treatment for nicotine withdrawal: a pilot double-blind, placebo-controlled, fixed-dose study in adult smokers

    Directory of Open Access Journals (Sweden)

    Silverstone Peter H

    2012-03-01

    Full Text Available Abstract Background Many effective treatments for nicotine addiction inhibit noradrenaline reuptake. Three recent studies have suggested that another noradrenaline reuptake inhibitor, atomoxetine, may reduce smoking behaviors. Methods The present double-blind, placebo-controlled, fixed-dose study was carried out over 21 days during which administration of 40 mg atomoxetine was compared to placebo in 17 individuals. Of these, nine were randomized to atomoxetine and eight to placebo. Baseline and weekly measurements were made using the Cigarette Dependence Scale (CDS, Cigarette Withdrawal Scale (CWS, Questionnaire of Smoking Urges (QSU, reported number of cigarettes smoked, and salivary cotinine levels. Results The study results showed that all those on placebo completed the study. In marked contrast, of the nine individuals who started on atomoxetine, five dropped out due to side effects. In a completer analysis there were statistically significant differences at 14 and 21 days in several measures between the atomoxetine and placebo groups, including CDS, CWS, QSU, number of cigarettes smoked (decreasing to less than two per day in the treatment group who completed the study, and a trend towards lower mean salivary cotinine levels. However, these differences were not seen in a last observation carried forward (LOCF analysis. Conclusions In summary, this is the first study to examine the use of atomoxetine in non-psychiatric adult smokers for a period of more than 7 days, and the findings suggest that atomoxetine might be a useful treatment for nicotine addiction. However, the dose used in the current study was too high to be tolerated by many adults, and a dose-finding study is required to determine the most appropriate dose for future studies of this potential treatment for smoking cessation.

  2. The Impact of a One-Dose versus Two-Dose Oral Cholera Vaccine Regimen in Outbreak Settings: A Modeling Study.

    Directory of Open Access Journals (Sweden)

    Andrew S Azman

    2015-08-01

    surveillance data and uncertainty about the transmission dynamics of cholera in each setting.Reactive vaccination campaigns using a single dose of OCV may avert more cases and deaths than a standard two-dose campaign when vaccine supplies are limited, while at the same time reducing logistical complexity. These findings should motivate consideration of the trade-offs between one- and two-dose campaigns in resource-constrained settings, though further field efficacy data are needed and should be a priority in any one-dose campaign.

  3. TL response of citrine samples for high-dose dosimetry

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines; Caldas, Linda V.E.

    2011-01-01

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the thermoluminescence technique (TL). In this work, the TL properties of citrine samples were studied. They were exposed to different doses of gamma radiation ( 60 Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tectosilicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO 2 ), and it has a lower symmetry and more compact reticulum. The citrine stone samples were powdered, and the selected grains were mixed with Teflon in the proportion 2 (Teflon):1 (Citrine). The mixture was pressed and sintered for production of Citrine -Teflon pellets of 50 mg. The TL emission curve showed two peaks at 160 deg C and 220 deg C. To remove the TL peak (160 deg C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The TL dose-response curve between 50 Gy and 100 kGy, the reproducibility of TL response and the lower detection dose were obtained. The preliminary results show that citrine may be useful for high-dose dosimetry. (author)

  4. Evaluation of the repeated dose liver micronucleus assay using young adult rats with cyclophosphamide monohydrate: a report of a collaborative study by CSGMT/JEMS.MMS.

    Science.gov (United States)

    Matsumoto, Kazumi; Zaizen, Kazuyo; Miyamoto, Atsushi; Wako, Yumi; Kawasako, Kazufumi; Ishida, Hisao

    2015-03-01

    The repeated dose liver micronucleus (RDLMN) assay using young adult rats has the potential to detect liver carcinogens, and this assay could be integrated into general toxicological studies. In this study, in order to assess the performance of the assay, cyclophosphamide monohydrate (CP) was tested in a 14-day RDLMN assay. Based on the results of the 4-day repeated dose-finding study, 10 mg/kg/day of CP was selected as the highest dose and the lower doses were set at 5, 2.5, 1.25, and 0.625 mg/kg/day for the 14-day RDLMN assay. On the day after the completion of the dosing period, specimens of hepatocytes and bone marrow cells were prepared and the induction of micronuclei was assessed. No changes were observed in the incidences of micronucleated hepatocytes. Nevertheless, the incidences of micronucleated immature erythrocytes in the bone marrow were increased significantly at CP doses of 1.25 mg/kg/day or more. These findings are consistent with reports that CP induces tumors in various tissues but it does not induce liver tumors.

  5. Preliminary study on the establishment of the radionuclide declaration methods for radionuclides in LILW radioactive waste

    International Nuclear Information System (INIS)

    Hwang, K. H.; Lee, K. J.; Jung, C. W.

    2003-01-01

    The preliminary study on declaration methods has been done for each radionuclide in LILW radwaste drum in Korean NPPs. View from the preliminary establishment of radio nuclide declaration methods, The selection of assessment target nuclide through the qualitative method and preliminary criteria for routine declaration methods in each radio nuclide was derived. First of all, selection criteria and preliminary assessment method for each target radionuclide was surveyed and investigated. And, the selection criteria and selected the target radio nuclides from the basis on criteria was derived. And the preliminary suggestion about the declaration methods for each target radio nuclide was established

  6. A preliminary assessment of the radiological impact of the Chernobyl reactor accident on the population of the European Community

    International Nuclear Information System (INIS)

    Morrey, M.; Brown, J.; Williams, J.A.; Crick, M.J.; Simmonds, J.R.; Hill, M.D.

    1988-01-01

    Following the Chernobyl accident the Commission of the European Communities asked the National Radiological Protection Board to carry out a preliminary assessment of the radiological consequences of the accident on the population of the European Community (EC). The aim of the study was to review information on the environmental contamination measured in member states of the EC; to make a preliminary assessment of individual and population doses for each country; to make an estimate of the resulting health impact and to indicate the effects of the various countermeasures taken by member states in terms of the reductions in both individual and population exposure which they produced. All of the main pathways by which people have been and will be exposed to radiation as a result of the accident were included in the assessment. The impact estimate is based on environmental measurements made during the month after the accident, and on calculations made using mathematical models of radionuclide transfer through the environment. The calculated effective doses to average individuals in EC countries from exposure over the next 50 years range from 0.3 μSv (in Portugal) to between about 300 and 500 μSv (in the FRG, Italy and Greece). The total collective effective dose to the population of EC countries, integrated over all time, is estimated to be about 80 000 man Sv. This may be compared to the collective effective dose from natural background radiation of about 500 000 man Sv every year. In some countries, the restrictions placed on consumption of some foods are estimated to have been effective in reducing doses to the most exposed individuals; the reduction being up to about a factor of 2. The results presented in this paper should therefore be regarded as preliminary

  7. Monochromatic x-rays for low-dose digital mammography: preliminary results.

    Science.gov (United States)

    Yoon, Kwon-Ha; Kwon, Young Man; Choi, Byoung-Jung; Son, Hyun Hwa; Ryu, Cheol Woo; Chon, Kwon Su; Park, Seong Hoon; Juhng, Sun Kwan

    2012-12-01

    The feasibility of using monochromatic x-ray imaging generated from an x-ray tube and a multilayer reflector for digital mammography with a low radiation dose was examined. A multilayer mirror was designed to select the x-ray peak with an energy of 21.5 keV generated from an x-ray tube with a tungsten target and was fabricated by the ion-beam sputtering deposition system. Monochromatic x-ray images were obtained from an experimental digital mammography setup with a scanning stage. The performance of the system was evaluated using a breast phantom, a spectrometer, and a radiation dosimeter. We measured the contrast-to-noise ratio and performed the 10% modulation function test to determine image quality and resolution. The monochromatic beam from the multilayer reflector had a full-width-at-half-maximum of 0.9 keV at 21.5 keV, and the reflectivity was 0.70, which was 90% of the designed value. The polychromatic and monochromatic x-rays showed radiation doses of 0.497 and 0.0415 mGy, respectively. The monochromatic x-ray image shows fibers, calcifications, and masses more clearly than the polychromatic x-ray images do. The image contrast of the monochromatic x-rays was 1.85 times higher than that of the polychromatic x-rays. The experimental mammography setup had a spatial resolution of 7 lp/mm with both x-rays. Monochromatic x-rays generated using a multilayer mirror may be a useful diagnostic tool for breast examination by providing high contrast imaging with a low radiation dose.

  8. Superselective angiographic findings and the blood supply in the cases of avascular necrosis of the femoral head: a preliminary study

    International Nuclear Information System (INIS)

    Zhou Weisheng; Wang Fangjun; Ling Yisheng; Zhao Tianqing

    2003-01-01

    Objective: To study the superselective angiographic findings and blood supply in the case of avascular necrosis of the femoral head (ANFH). Methods: One hundred and sixty five patients (214 hips) with ANFH proved by clinic and radiology underwent superselective angiography and DSA findings were retrospectively studied. Results: Abnormal angiographic findings of the medial circumflex artery and its branches, with or without other abnormal vascularities, could be obtained in 162 hips out of 211 (98.6%). Angiographic findings of ANFH were the followings: abnormal superior and inferior capsular branch of the medial circumflex artery, especially the former one; abnormalities in the ascending branch of lateral circumflex artery; opacification of the femoral head and neck in the parenchymal phase of DSA; revasculization of the small arterial branches or a hypervascular area surrounding the necrotic lesions; anastomosis between the medial circumflex artery and the inferior and superior gluteal arteries; and the venous stasis. Conclusion: Morphological changes of blood vessels in ANFH are demonstrated by superselective angiography, in which the medial circumflex artery and its branches are mostly involved, or in some cases, accompanied by venous stasis

  9. Dose finding of melatonin for chronic idiopathic childhood sleep onset insomnia: an RCT

    OpenAIRE

    van Geijlswijk, Ingeborg M.; van der Heijden, Kristiaan B.; Egberts, A. C. G.; Korzilius, Hubert P. L. M.; Smits, Marcel G.

    2010-01-01

    RATIONALE: Pharmacokinetics of melatonin in children might differ from that in adults. OBJECTIVES: This study aims to establish a dose-response relationship for melatonin in advancing dim light melatonin onset (DLMO), sleep onset (SO), and reducing sleep onset latency (SOL) in children between 6 and 12 years with chronic sleep onset insomnia (CSOI). METHODS: The method used for this study is the randomized, placebo-controlled double-blind trial. Children with CSOI (n = 72) received either mel...

  10. Intra-voxel heterogeneity influences the dose prescription for dose-painting with radiotherapy: a modelling study

    NARCIS (Netherlands)

    Petit, S.F.; Dekker, A.L.A.J.; Seigneuric, R.; Murrer, L.H.P.; Riel, van N.A.W.; Nordsmark, M.; Overgaard, J.; Lambin, Ph.; Wouters, B.G.

    2009-01-01

    The purpose of this study was to increase the potential of dose redistribution by incorporating estimates of oxygen heterogeneity within imaging voxels for optimal dose determination. Cellular oxygen tension (pO2) distributions were estimated for imaging-size-based voxels by solving oxygen

  11. 4. Preliminary Findings of a Prospective Study of FDG-PET in Patients with Possible Lung Cancer

    DEFF Research Database (Denmark)

    Mortensen; Enevoldsen; Friberg

    2000-01-01

    Purpose: To examine the value of PET in diagnosis and staging of suspected lung cancer.Methods: 20 (13 male; mean age: 56 yr., range: 22-83 yr.) patients with chest X-ray findings suspicious of malignancy were staged a) "clinically" (X-ray, history/physical examination, lung function), b) by chest......%) patients surgery was avoided mainly because of the PET findings. In one SCLC patient and one lymphoma patient, PET showed extensive disease, which changed the chemotherapy regime. Accuracy was 83% for clinical stage, 79% for CT and 77% for PET. Four (20%) false positive PET findings were caused...

  12. Ayahuasca-assisted therapy for addiction: results from a preliminary observational study in Canada.

    Science.gov (United States)

    Thomas, Gerald; Lucas, Philippe; Capler, N Rielle; Tupper, Kenneth W; Martin, Gina

    2013-03-01

    This paper reports results from a preliminary observational study of ayahuasca-assisted treatment for problematic substance use and stress delivered in a rural First Nations community in British Columbia, Canada. The "Working with Addiction and Stress" retreats combined four days of group counselling with two expert-led ayahuasca ceremonies. This study collected pre-treatment and six months follow-up data from 12 participants on several psychological and behavioral factors related to problematic substance use, and qualitative data assessing the personal experiences of the participants six months after the retreat. Statistically significant (p ayahuasca-assisted therapy appears to be associated with statistically significant improvements in several factors related to problematic substance use among a rural aboriginal population. These findings suggest participants may have experienced positive psychological and behavioral changes in response to this therapeutic approach, and that more rigorous research of ayahuasca-assisted therapy for problematic substance use is warranted.

  13. The preliminary research for biosynthetic engineering by radiation fusion technology

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Chang Hyun; Jung, U Hee; Park, Hae Ran [KAERI, Daejeon (Korea, Republic of)

    2012-01-15

    The purpose of this project is to elucidate the solution to the production of bioactive substance using biotransformation process from core technology of biosynthetic engineering by radiation fusion technology. And, this strategy will provide core technology for development of drugs as new concept and category. Research scopes and contents of project include 1) The development of mutant for biosynthetic engineering by radiation fusion technology 2) The development of host for biosynthetic engineering by radiation fusion technology 3) The preliminary study for biosynthetic engineering of isoflavone by radiation fusion technology. The results are as follows. Isoflavone compounds(daidzein, hydroxylated isoflavone) were analyzed by GC-MS. The study of radiation doses and p-NCA high-throughput screening for mutant development were elucidated. And, it was carried out the study of radiation doses for host development. Furthermore, the study of redox partner and construction of recombinant strain for region-specific hydroxylation(P450, redox partner). In addition, the biological effect of 6,7,4'-trihydroxyisoflavone as an anti-obesity agent was elucidated in this study.

  14. Skin dose assessment in routine personnel beta/gamma dosimetry

    International Nuclear Information System (INIS)

    Christensen, P.

    1980-01-01

    Three alternative methods are outlined by which substantial improvements of the capabilities of existing routine monitoring systems for skin dose assessment can be obtained. The introduction of a supplementary skin dosemeter may be an attractive method for systems with badges that have a capability for an additional dosemeter already built-in. The two-side reading method has limited possibilities because of reduced accuracy for mixed radiation and technical difficulties in using it for TLD systems with planchet heating. The use of a boron diffused LiF layer for skin dose assessment seems to be most attractive method since the only modification needed here is replacement of a dosemeter. However the study of this method is so far only in a preliminary stage and further investigations are needed. (U.K.)

  15. Preliminary study on the dye removal efficacy of immobilized marine ...

    African Journals Online (AJOL)

    Preliminary study on the dye removal efficacy of immobilized marine and freshwater microalgal beads from textile wastewater. SD Kumar, P Santhanam, R Nandakumar, S Anath, B Balaji Prasath, A Shenbaga Devi, S Jeyanthi, T Jayalakshima, P Ananthi ...

  16. Evaluation of the Basedow disease treatment by a iodine 131 fixed dose; Evaluation du traitement de la maladie de Basedow par une dose fixe d'iode 131

    Energy Technology Data Exchange (ETDEWEB)

    El Ajmi, W.; Slim, I; Rmadi, S.; Yeddes, I.; Krimi, S.; Ltaief, B.; Mhiri, A.; Ben Slimene, M.F. [Service de medecine nucleaire, institut Salah Azeiz, Tunis, (Tunisia)

    2009-05-15

    The treatment of the basedow disease by iodine 131 is more and more used. however, the doses used stay variable. In order to reduce the treatment failure, we chose a protocol with strong fix doses of iodine 131. We give our preliminary results for 63 patients. The treatment by strong fix dose of iodine 131 is simple, safe and efficient for the control of hyperthyroidism in the Basedow disease. This protocol has for advantage to be simpler comparatively to these ones using adjusted doses according the weight of the thyroid and its fixation rate. (N.C.)

  17. Preliminary studies to determine the shelf life of HEPA filters. Revision 1

    International Nuclear Information System (INIS)

    Gilbert, H.; Fretthold, J.K.; Rainer, F.; Bergman, W.; Beason, D.

    1995-02-01

    We have completed a preliminary study using filter media tests and filter qualification tests to investigate the effect of shelf-life on HEPA filter performance. Our media studies showed that the tensile strength decreased with age, but the data were not sufficient to establish a shelf-life. Thermogravimetric analyses demonstrated that one manufacturer had media with low tensile strength due to insufficient binder. The filter qualification tests (heated air and overpressure) conducted on different aged filters showed that filter age is not the primary factor affecting filter performance; materials and the construction design have a greater effect. An unexpected finding of our study was that sub-standard HEPA filters have been installed in DOE facilities despite existing regulations and filter qualification tests. We found that the filter with low tensile strength failed the overpressure test. The same filter had passed the heated air test, but left the filter so structurally weak, it was prone to blow-out. We recommend that DOE initiate a filter qualification program to prevent this occurrence

  18. Polymer gel dosimetry for synchrotron stereotactic radiotherapy and iodine dose-enhancement measurements

    International Nuclear Information System (INIS)

    Boudou, C; Tropres, I; Rousseau, J; Lamalle, L; Adam, J F; Esteve, F; Elleaume, H

    2007-01-01

    Synchrotron stereotactic radiotherapy (SSR) is a radiotherapy technique that makes use of the interactions of monochromatic low energy x-rays with high atomic number (Z) elements. An important dose-enhancement can be obtained if the target volume has been loaded with a sufficient amount of a high-Z element, such as iodine. In this study, we compare experimental dose measurements, obtained with normoxic polymer gel (nPAG), with Monte Carlo computations. Gels were irradiated within an anthropomorphic head phantom and were read out by magnetic resonance imaging. The dose-enhancement due to the presence of iodine in the gel (iodine concentration: 5 and 10 mg ml -1 ) was measured at two radiation energies (35 and 80 keV) and was compared to the calculated factors. nPAG dosimetry was shown to be efficient for measuring the sharp dose gradients produced by SSR. The agreement between 3D gel dosimetry and calculated dose distributions was found to be within 4% of the dose difference criterion and a distance to agreement of 2.1 mm for 80% of the voxels. Polymer gel doped with iodine exhibited higher sensitivity, in good agreement with the calculated iodine-dose enhancement. We demonstrate in this preliminary study that iodine-doped nPAG could be used for measuring in situ dose distributions for iodine-enhanced SSR treatment

  19. SU-G-IeP3-12: Preliminary Report On the Experience of Patient Radiation Dose Monitoring and Tracking Systems; PEMNET, Radimetrics and DoseWatch

    International Nuclear Information System (INIS)

    Lin, P; Corwin, F; Ghita, M

    2016-01-01

    Purpose: Three patient radiation dose monitoring and tracking (PRDMT) systems have been in operation at this institution for the past 6 months. There are useful information that should be disseminated to those who are considering installation of PRDMT programs. In addition, there are “problems” uncovered in the process of estimating fluoroscopic “peak” skin dose (PSD), especially, for those patients who received interventional angiographic studies and in conjunction with surgical procedures. Methods: Upon exporting the PRDMT data to Microsoft Excel program, the peak skin dose can be estimated by applying various correction factors including; attenuation due to the tabletop and examination mattress, table height, tabletop translation, backscatter, etc. A procedure was established to screen and divide the PRDMT reported radiation dose and estimated PSD to three different levels of threshold to assess the potential skin injuries, to assist patient follow-up, risk management and provide radiation dosimetry information in case of “Sentinel Event”. Results: The Radiation Dose Structured Report (RDSR) was found to be the prerequisite for the PRDMT systems to work seamlessly. And, the geometrical parameters (gantry and table orientation) displayed by the equipment are not necessarily implemented in the “patient centric” manner which could result in a large error in the PSD estimation. Since, the PRDMT systems obtain their pertinent data from the DICOM tags including the polarity (+ and − signs), the geometrical parameters need to be verified. Conclusion: PRDMT systems provide a more accurate PSD estimation than previously possible as the air-kerma-area dose meter become widely implemented. However, care should be exercised to correctly apply the geometrical parameters in estimating the patient dose. In addition, further refinement is necessary for these software programs to account for all geometrical parameters such as the tabletop translation in the z

  20. SU-G-IeP3-12: Preliminary Report On the Experience of Patient Radiation Dose Monitoring and Tracking Systems; PEMNET, Radimetrics and DoseWatch

    Energy Technology Data Exchange (ETDEWEB)

    Lin, P; Corwin, F; Ghita, M [Virginia Commonwealth University Medical Center, Richmond, VA (United States)

    2016-06-15

    Purpose: Three patient radiation dose monitoring and tracking (PRDMT) systems have been in operation at this institution for the past 6 months. There are useful information that should be disseminated to those who are considering installation of PRDMT programs. In addition, there are “problems” uncovered in the process of estimating fluoroscopic “peak” skin dose (PSD), especially, for those patients who received interventional angiographic studies and in conjunction with surgical procedures. Methods: Upon exporting the PRDMT data to Microsoft Excel program, the peak skin dose can be estimated by applying various correction factors including; attenuation due to the tabletop and examination mattress, table height, tabletop translation, backscatter, etc. A procedure was established to screen and divide the PRDMT reported radiation dose and estimated PSD to three different levels of threshold to assess the potential skin injuries, to assist patient follow-up, risk management and provide radiation dosimetry information in case of “Sentinel Event”. Results: The Radiation Dose Structured Report (RDSR) was found to be the prerequisite for the PRDMT systems to work seamlessly. And, the geometrical parameters (gantry and table orientation) displayed by the equipment are not necessarily implemented in the “patient centric” manner which could result in a large error in the PSD estimation. Since, the PRDMT systems obtain their pertinent data from the DICOM tags including the polarity (+ and − signs), the geometrical parameters need to be verified. Conclusion: PRDMT systems provide a more accurate PSD estimation than previously possible as the air-kerma-area dose meter become widely implemented. However, care should be exercised to correctly apply the geometrical parameters in estimating the patient dose. In addition, further refinement is necessary for these software programs to account for all geometrical parameters such as the tabletop translation in the z

  1. Repeated dose titration versus age-based method in electroconvulsive therapy: a pilot study.

    Science.gov (United States)

    Aten, Jan Jaap; Oudega, Mardien; van Exel, Eric; Stek, Max L; van Waarde, Jeroen A

    2015-06-01

    In electroconvulsive therapy (ECT), a dose titration method (DTM) was suggested to be more individualized and therefore more accurate than formula-based dosing methods. A repeated DTM (every sixth session and dose adjustment accordingly) was compared to an age-based method (ABM) regarding treatment characteristics, clinical outcome, and cognitive functioning after ECT. Thirty-nine unipolar depressed patients dosed using repeated DTM and 40 matched patients treated with ABM were compared. Montgomery-Åsberg Depression Rating Scale (MADRS) and Mini-Mental State Examination (MMSE) were assessed at baseline and at the end of the index course, as well as the total number of ECT sessions. Both groups were similar regarding age, sex, psychotic features, mean baseline MADRS, and median baseline MMSE. At the end of the index course, the two methods showed equal outcome (mean end MADRS, 11.6 ± 8.3 in DTM and 9.5 ± 7.6 in ABM (P = 0.26); median end MMSE, 28 (25-29) and 28 (25-29.8), respectively (P = 0.81). However, the median number of all ECT sessions differed 16 (11-22) in DTM versus 12 (10-14.8) in ABM; P = 0.02]. Using regression analysis, dosing method and age were independently associated with the total number of ECT sessions, with less sessions needed in ABM (P = 0.02) and in older patients (P = 0.001). In this comparative cohort study, ABM and DTM showed equal outcome for depression and cognition. However, the median ECT course duration in repeated DTM appeared longer. Additionally, higher age was associated with shorter ECT courses regardless of the dosing method. Further prospective studies are needed to confirm these findings.

  2. Concomitant radiation therapy and doxorubicin by continuous Infusion in advanced malignancies - A phase I-II study - evidence of synergistic effect in Soft tissue sarcomas and hepatomas

    International Nuclear Information System (INIS)

    Rosenthal, C.J.; Bhutiani, I.; Rotman, M.

    1986-01-01

    This paper attempts to establish the dose and the duration of administration of doxorubicin infusion having the best therapeutic index and to determine the dose of radiation which in combination with the optimal dose of doxorubicin administered by continuous infusion would have the best therapeutic index. The authors attempt to find the nature and the incidence of side effects of these combined modalities of therapy. The therapeutic effect of the optimal doxorubicin infusion dose in combination with concomitant radiotherapy is assessed in a preliminary study and it was found to have a significant enhancing effect in a few cases of hepatomas and in most of the cases of recurrent and metastatic soft tissue sarcomas

  3. Hydrogen Gas Retention and Release from WTP Vessels: Summary of Preliminary Studies

    Energy Technology Data Exchange (ETDEWEB)

    Gauglitz, Phillip A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bontha, Jagannadha R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Daniel, Richard C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Mahoney, Lenna A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rassat, Scot D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wells, Beric E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bao, Jie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Boeringa, Gregory K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Buchmiller, William C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Burns, Carolyn A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chun, Jaehun [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Karri, Naveen K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Li, Huidong [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Tran, Diana N. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-07-01

    The Hanford Waste Treatment and Immobilization Plant (WTP) is currently being designed and constructed to pretreat and vitrify a large portion of the waste in the 177 underground waste storage tanks at the Hanford Site. A number of technical issues related to the design of the pretreatment facility (PTF) of the WTP have been identified. These issues must be resolved prior to the U.S. Department of Energy (DOE) Office of River Protection (ORP) reaching a decision to proceed with engineering, procurement, and construction activities for the PTF. One of the issues is Technical Issue T1 - Hydrogen Gas Release from Vessels (hereafter referred to as T1). The focus of T1 is identifying controls for hydrogen release and completing any testing required to close the technical issue. In advance of selecting specific controls for hydrogen gas safety, a number of preliminary technical studies were initiated to support anticipated future testing and to improve the understanding of hydrogen gas generation, retention, and release within PTF vessels. These activities supported the development of a plan defining an overall strategy and approach for addressing T1 and achieving technical endpoints identified for T1. Preliminary studies also supported the development of a test plan for conducting testing and analysis to support closing T1. Both of these plans were developed in advance of selecting specific controls, and in the course of working on T1 it was decided that the testing and analysis identified in the test plan were not immediately needed. However, planning activities and preliminary studies led to significant technical progress in a number of areas. This report summarizes the progress to date from the preliminary technical studies. The technical results in this report should not be used for WTP design or safety and hazards analyses and technical results are marked with the following statement: “Preliminary Technical Results for Planning – Not to be used for WTP Design

  4. Finding the optimal dose of vitamin K1 to treat vitamin K deficiency and to avoid anaphylactoid reactions.

    Science.gov (United States)

    Mi, Yan-Ni; Ping, Na-Na; Li, Bo; Xiao, Xue; Zhu, Yan-Bing; Cao, Lei; Ren, Jian-Kang; Cao, Yong-Xiao

    2017-10-01

    Vitamin K1 injection induces severe dose-related anaphylactoid reactions and overdose for the treatment of vitamin K deficiency. We aimed to find an optimal and small dose of vitamin K1 injection to treat vitamin K deficiency and avoid anaphylactoid reactions in animal. Rats were administered a vitamin K-deficient diet and gentamicin to establish vitamin K deficiency model. Behaviour tests were performed in beagle dogs to observe anaphylactoid reactions. The results showed an increased protein induced by vitamin K absence or antagonist II (PIVKA-II) levels, a prolonging of prothrombin time (PT) and activated partial thromboplastin time (APTT) and a decrease in vitamin K-dependent coagulation factor (F) II, VII, IX and X activities in the model group. In vitamin K1 0.01 mg/kg group, the liver vitamin K1 levels increased fivefold and the liver vitamin K2 levels increased to the normal amount. Coagulation markers PT, APTT, FVII and FIX activities returned to normal. Both in the 0.1 and 1.0 mg/kg vitamin K1 groups, coagulation functions completely returned to normal. Moreover, the amount of liver vitamin K1 was 40 (0.1 mg/kg) or 100 (1.0 mg/kg) times as in normal. Vitamin K2 was about 4 (0.1 mg/kg) or 5 (1.0 mg/kg) times as the normal amount. There was no obvious anaphylactoid symptom in dogs with the dose of 0.03 mg/kg, which is equivalent to the dose of 0.01 mg/kg in rats. These results demonstrated that a small dose of vitamin K1 is effective to improve vitamin K deficiency and to prevent anaphylactoid reactions, simultaneously. © 2017 Société Française de Pharmacologie et de Thérapeutique.

  5. Radiology workstation for mammography: preliminary observations, eyetracker studies, and design

    Science.gov (United States)

    Beard, David V.; Johnston, Richard E.; Pisano, Etta D.; Hemminger, Bradley M.; Pizer, Stephen M.

    1991-07-01

    For the last four years, the UNC FilmPlane project has focused on constructing a radiology workstation facilitating CT interpretations equivalent to those with film and viewbox. Interpretation of multiple CT studies was originally chosen because handling such large numbers of images was considered to be one of the most difficult tasks that could be performed with a workstation. The authors extend the FilmPlane design to address mammography. The high resolution and contrast demands coupled with the number of images often cross- compared make mammography a difficult challenge for the workstation designer. This paper presents the results of preliminary work with workstation interpretation of mammography. Background material is presented to justify why the authors believe electronic mammographic workstations could improve health care delivery. The results of several observation sessions and a preliminary eyetracker study of multiple-study mammography interpretations are described. Finally, tentative conclusions of what a mammographic workstation might look like and how it would meet clinical demand to be effective are presented.

  6. Micro-dosing for early biokinetic studies in humans

    International Nuclear Information System (INIS)

    Stenstroem, K.; Sydoff, M.; Mattsson, S.

    2010-01-01

    Micro-dosing is a new concept in drug development that-if implemented in the pharmaceutical industry-would mean that new drugs can be tested earlier in humans than done today. The human micro-dosing concept-or 'Phase 0'-may offer improved candidate selection, reduced failure rates in the drug development line and a reduction in the use of laboratory animals in early drug development, factors which will help to speed up drug development and also reduce the costs. Micro-dosing utilises sub-pharmacological amounts of the substance to open opportunities for early studies in man. Three technologies are used for micro-dosing: accelerator mass spectrometry (AMS), positron emission tomography and liquid chromatography-tandem mass spectrometry. This paper focuses on the principle of AMS and discusses the current status of micro-dosing with AMS. (authors)

  7. The FIND-CKD study--a randomized controlled trial of intravenous iron versus oral iron in non-dialysis chronic kidney disease patients: background and rationale.

    Science.gov (United States)

    Macdougall, Iain C; Bock, Andreas; Carrera, Fernando; Eckardt, Kai-Uwe; Gaillard, Carlo; Van Wyck, David; Roubert, Bernard; Cushway, Timothy; Roger, Simon D

    2014-04-01

    Rigorous data are sparse concerning the optimal route of administration and dosing strategy for iron therapy with or without concomitant erythropoiesis-stimulating agent (ESA) therapy for the management of iron deficiency anaemia in patients with non-dialysis dependent chronic kidney disease (ND-CKD). FIND-CKD was a 56-week, open-label, multicentre, prospective, randomized three-arm study (NCT00994318) of 626 patients with ND-CKD and iron deficiency anaemia randomized to (i) intravenous (IV) ferric carboxymaltose (FCM) at an initial dose of 1000 mg iron with subsequent dosing as necessary to target a serum ferritin level of 400-600 µg/L (ii) IV FCM at an initial dose of 200 mg with subsequent dosing as necessary to target serum ferritin 100-200 µg/L or (iii) oral ferrous sulphate 200 mg iron/day. The primary end point was time to initiation of other anaemia management (ESA therapy, iron therapy other than study drug or blood transfusion) or a haemoglobin (Hb) trigger (two consecutive Hb values FIND-CKD was the longest randomized trial of IV iron therapy to date. Its findings will address several unanswered questions regarding iron therapy to treat iron deficiency anaemia in patients with ND-CKD. It was also the first randomized trial to utilize both a high and low serum ferritin target range to adjust IV iron dosing, and the first not to employ Hb response as its primary end point.

  8. PTSD and Impaired Eye Expression Recognition: A Preliminary Study

    Science.gov (United States)

    Schmidt, Jakob Zeuthen; Zachariae, Robert

    2009-01-01

    This preliminary study examined whether posttraumatic stress disorder (PTSD) was related to difficulties in identifying the mental states of others in a group of refugees. Sixteen Bosnian refugees, referred to treatment in an outpatient treatment center for survivors of torture and war-related trauma in Denmark (CETT), were compared to 16 non-PTSD…

  9. Defibrotide for the treatment of severe hepatic veno-occlusive disease and multiorgan failure after stem cell transplantation: a multicenter, randomized, dose-finding trial.

    Science.gov (United States)

    Richardson, Paul G; Soiffer, Robert J; Antin, Joseph H; Uno, Hajime; Jin, Zhezhen; Kurtzberg, Joanne; Martin, Paul L; Steinbach, Gideon; Murray, Karen F; Vogelsang, Georgia B; Chen, Allen R; Krishnan, Amrita; Kernan, Nancy A; Avigan, David E; Spitzer, Thomas R; Shulman, Howard M; Di Salvo, Donald N; Revta, Carolyn; Warren, Diane; Momtaz, Parisa; Bradwin, Gary; Wei, L J; Iacobelli, Massimo; McDonald, George B; Guinan, Eva C

    2010-07-01

    Therapeutic options for severe hepatic veno-occlusive disease (VOD) are limited and outcomes are dismal, but early phase I/II studies have suggested promising activity and acceptable toxicity using the novel polydisperse oligonucleotide defibrotide. This randomized phase II dose-finding trial determined the efficacy of defibrotide in patients with severe VOD following hematopoietic stem cell transplantation (HSCT) and identified an appropriate dose for future trials. Adult and pediatric patients received either lower-dose (arm A: 25 mg/kg/day; n = 75) or higher-dose (arm B: 40 mg/kg/day; n = 74) i.v. defibrotide administered in divided doses every 6 hours for > or =14 days or until complete response, VOD progression, or any unacceptable toxicity occurred. Overall complete response and day +100 post-HSCT survival rates were 46% and 42%, respectively, with no significant difference between treatment arms. The incidence of treatment-related adverse events was low (8% overall; 7% in arm A, 10% in arm B); there was no significant difference in the overall rate of adverse events between treatment arms. Early stabilization or decreased bilirubin was associated with better response and day +100 survival, and decreased plasminogen activator inhibitor type 1 (PAI-1) during treatment was associated with better outcome; changes were similar in both treatment arms. Defibrotide 25 or 40 mg/kg/day also appears effective in treating severe VOD following HSCT. In the absence of any differences in activity, toxicity or changes in PAI-1 level, defibrotide 25 mg/kg/day was selected for ongoing phase III trials in VOD.

  10. Spirituality and the Events of September 11: A Preliminary Study

    Science.gov (United States)

    Briggs, Michele Kielty; Apple, Kevin J.; Aydlett, Ann E.

    2004-01-01

    Personal crises have been associated with spiritual growth. Sparked by the global response to the crisis of September 11, 2001, this study examined the relationship of spirituality and the September 11 tragedy using a sample of convenience from a college student population. This preliminary study used an experimental design to examine various…

  11. An epidemiological study for the reduction of population radiation dose

    International Nuclear Information System (INIS)

    Gamo, Makoto

    1989-01-01

    The correlation of tube voltage with patient exposure was studied using effective dose as an indicator of dose reduction in intraoral radiography. The results were as follows: l. The salivary gland tissues contributed the most to the effective dose of intraoral radiography. 2. In the 50 to 90 kV range, there was no appreciable correlation between tube voltage and effective dose. 3. Therefore, it was suggested that adjusting the tube voltage for maximum image quality does not effect radiation protection. 4. This study reconfirmed the fact that increases in voltages up to 90 kV reduce skin doses. (author)

  12. Study of single dose toxic test of Sweet Bee Venom in Beagle Dogs

    Directory of Open Access Journals (Sweden)

    Hye-Chul, Yoon

    2010-12-01

    Full Text Available Objectives : This study was performed to analyse single dose toxicity of Sweet Bee Venom(Sweet BV extracted from the bee venom in Beagle dogs. Methods : All experiments were conducted under the regulations of Good Laboratory Practice (GLP at Biotoxtech Company, a non-clinical study authorized institution. Male and female Beagle dogs of 5-6 months old were chosen for the pilot study of single dose toxicity of Sweet BV which was administered at the level of 9.0 ㎎/㎏ body weight which is 1300 times higher than the clinical application dosage as the high dosage, followed by 3.0 and 1.0 ㎎/㎏ as midium and low dosage, respectively. Equal amount of excipient(normal saline to the Sweet BV experiment groups was administered as the control group. Results : 1. No mortality was witnessed in all of the experiment groups. 2. Hyperemia and movement disorder were observed around the area of administration in all the experiment groups, and higher occurrence in the higher dosage treatment. 3. For weight measurement, Neither male nor female groups showed significant changes. 4. To verify abnormalities of organs and tissues, thigh muscle which treated with Sweet BV, brain, liver, lung, kidney, and spinal cords were removed and histologocal observation using H-E staining was conducted. In the histologocal observation of thigh muscle, cell infiltration, inflammation, degeneration, necrosis of muscle fiber, and fibrosis were found in both thigh tissue. And the changes depend on the dose of Sweet BV. But the other organs did not showed in any abnormality. 5. The maximum dose of Sweet BV in Beagle dogs were over 9 ㎎/㎏ in this study. Conclusions : The above findings of this study suggest that Sweet BV is a relatively safe treatment medium. Further studies on the toxicity of Sweet BV should be conducted to yield more concrete evidences.

  13. Review of low dose-rate epidemiological studies and biological mechanisms of dose-rate effects on radiation induced carcinogenesis

    International Nuclear Information System (INIS)

    Iwasaki, Toshiyasu; Otsuka, Kensuke; Yoshida, Kazuo

    2015-01-01

    Radiation protection system adopts the linear non-threshold model with using dose and dose-rate effectiveness factor (DDREF). The dose-rate range where DDREF is applied is below 100 mGy per hour, and it is regarded that there are no dose-rate effects at very low dose rate, less than of the order of 10 mGy per year, even from the biological risk evaluation model based on cellular and molecular level mechanisms for maintenance of genetic integrity. Among low dose-rate epidemiological studies, studies of residents in high natural background areas showed no increase of cancer risks at less than about 10 mGy per year. On the other hand, some studies include a study of the Techa River cohort suggested the increase of cancer risks to the similar degree of Atomic bomb survivor data. The difference of those results was supposed due to the difference of dose rate. In 2014, International Commission on Radiological Protection opened a draft report on stem cell biology for public consultations. The report proposed a hypothesis based on the new idea of stem cell competition as a tissue level quality control mechanism, and suggested that it could explain the dose-rate effects around a few milligray per year. To verify this hypothesis, it would be needed to clarify the existence and the lowest dose of radiation-induced stem cell competition, and to elucidate the rate of stem cell turnover and radiation effects on it. As for the turnover, replenishment of damaged stem cells would be the important biological process. It would be meaningful to collect the information to show the difference of dose rates where the competition and the replenishment would be the predominant processes. (author)

  14. Risk of solid cancer in low dose-rate radiation epidemiological studies and the dose-rate effectiveness factor.

    Science.gov (United States)

    Shore, Roy; Walsh, Linda; Azizova, Tamara; Rühm, Werner

    2017-10-01

    Estimated radiation risks used for radiation protection purposes have been based primarily on the Life Span Study (LSS) of atomic bomb survivors who received brief exposures at high dose rates, many with high doses. Information is needed regarding radiation risks from low dose-rate (LDR) exposures to low linear-energy-transfer (low-LET) radiation. We conducted a meta-analysis of LDR epidemiologic studies that provide dose-response estimates of total solid cancer risk in adulthood in comparison to corresponding LSS risks, in order to estimate a dose rate effectiveness factor (DREF). We identified 22 LDR studies with dose-response risk estimates for solid cancer after minimizing information overlap. For each study, a parallel risk estimate was derived from the LSS risk model using matching values for sex, mean ages at first exposure and attained age, targeted cancer types, and accounting for type of dosimetric assessment. For each LDR study, a ratio of the excess relative risk per Gy (ERR Gy -1 ) to the matching LSS ERR risk estimate (LDR/LSS) was calculated, and a meta-analysis of the risk ratios was conducted. The reciprocal of the resultant risk ratio provided an estimate of the DREF. The meta-analysis showed a LDR/LSS risk ratio of 0.36 (95% confidence interval [CI] 0.14, 0.57) for the 19 studies of solid cancer mortality and 0.33 (95% CI 0.13, 0.54) when three cohorts with only incidence data also were added, implying a DREF with values around 3, but statistically compatible with 2. However, the analyses were highly dominated by the Mayak worker study. When the Mayak study was excluded the LDR/LSS risk ratios increased: 1.12 (95% CI 0.40, 1.84) for mortality and 0.54 (95% CI 0.09, 0.99) for mortality + incidence, implying a lower DREF in the range of 1-2. Meta-analyses that included only cohorts in which the mean dose was LDR data provide direct evidence regarding risk from exposures at low dose rates as an important complement to the LSS risk estimates used

  15. Dose-stress synergism in cancer risk assessment

    International Nuclear Information System (INIS)

    Pop-Jordanova, N.; Pop-Jordanov, J.

    2001-01-01

    Our hypothesis is that the relatively low risk of cancer or leukaemia from depleted uranium, as predicted by the World Health Organization and the International Atomic Energy Agency, is a result of neglecting the synergism between physico-chemical agents and psychological stress agents (here shortly denoted as dose-stress synergism). We use the modified risk assessment model that comprises a psycho-somatic extension, originally developed by us for assessing the risks of energy sources. Our preliminary meta-analysis of animal and human studies on cancers confirmed the existence of stress effects, including the amplifying synergism. Consequently, the psychological stress can increase the probability of even small toxic chemical or ionizing radiation exposure to produce malignancy. Such dose-stress synergism might influence the health risks among military personnel and the residents in the highly stressful environment in the Balkans. Further investigation is needed to estimate the order of magnitude of these combined effects in particular circumstances. (Original)

  16. Dose assessment at Bikini Atoll

    International Nuclear Information System (INIS)

    Robison, W.L.; Phillips, W.A.; Colsher, C.S.

    1977-01-01

    Bikini Atoll is one of two sites in the northern Marshall Islands that was used by the United States as testing grounds for the nuclear weapons program from 1946 to 1958. In 1969 a general cleanup began at Bikini Atoll. Subsistence crops, coconut and Pandanus fruit, were planted on Bikini and Eneu Islands, and housing was constructed on Bikini Island. A second phase of housing was planned for the interior of Bikini Island. Preliminary data indicated that external gamma doses in the interior of the island might be higher than in other parts of the island. Therefore, to select a second site for housing on the island with minimum external exposure, a survey of Bikini Atoll was conducted in June 1975. External gamma measurements were made on Bikini and Eneu Islands, and soil and vegetations samples collected to evaluate the potential doses via terrestrial food chains and inhalation. Estimates of potential dose via the marine food chain were based upon data collected on previous trips to the atoll. The terrestrial pathway contributes the greater percentage, external gamma exposure contributes the next highest, and inhalation and marine pathways contribute minor fractions of the total whole body and bone marrow doses. The radionuclides contributing the major fraction of the dose are 90 Sr and 137 Cs. All living patterns involving Bikini Island exceed federal guidelines for 30-yr population doses. The Eneu Island living pattern leads to doses that are slightly less than federal guidelines. All patterns evaluated for Bikini Atoll lead to higher doses than those on the southern islands at Enewetak Atoll

  17. A preliminary study on the relevancy of sustainable building design ...

    African Journals Online (AJOL)

    This preliminary study aims to explore the relationship between sustainable building design paradigms and commercial property depreciation, to assist in the understanding of sustainable building design impact towards commercial building value and rental de employs the qualitative method and analyses valuers' current ...

  18. A Preliminary Study toward Consistent Soil Moisture from AMSR2

    NARCIS (Netherlands)

    Parinussa, R.M.; Holmes, T.R.H.; Wanders, N.; Dorigo, W.A.; de Jeu, R.A.M.

    2015-01-01

    A preliminary study toward consistent soil moisture products from the Advanced Microwave Scanning Radiometer 2 (AMSR2) is presented. Its predecessor, the Advanced Microwave Scanning Radiometer for Earth Observing System (AMSR-E), has providedEarth scientists with a consistent and continuous global

  19. Biota Modeling in EPA's Preliminary Remediation Goal and Dose Compliance Concentration Calculators for Use in EPA Superfund Risk Assessment: Explanation of Intake Rate Derivation, Transfer Factor Compilation, and Mass Loading Factor Sources

    International Nuclear Information System (INIS)

    Manning, Karessa L.; Dolislager, Fredrick G.; Bellamy, Michael B.

    2016-01-01

    The Preliminary Remediation Goal (PRG) and Dose Compliance Concentration (DCC) calculators are screening level tools that set forth Environmental Protection Agency's (EPA) recommended approaches, based upon currently available information with respect to risk assessment, for response actions at Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) sites, commonly known as Superfund. The screening levels derived by the PRG and DCC calculators are used to identify isotopes contributing the highest risk and dose as well as establish preliminary remediation goals. Each calculator has a residential gardening scenario and subsistence farmer exposure scenarios that require modeling of the transfer of contaminants from soil and water into various types of biota (crops and animal products). New publications of human intake rates of biota; farm animal intakes of water, soil, and fodder; and soil to plant interactions require updates be implemented into the PRG and DCC exposure scenarios. Recent improvements have been made in the biota modeling for these calculators, including newly derived biota intake rates, more comprehensive soil mass loading factors (MLFs), and more comprehensive soil to tissue transfer factors (TFs) for animals and soil to plant transfer factors (BV's). New biota have been added in both the produce and animal products categories that greatly improve the accuracy and utility of the PRG and DCC calculators and encompass greater geographic diversity on a national and international scale.

  20. Dose response study of PVA-Fx gel for three dimensional dose distribution

    International Nuclear Information System (INIS)

    Brindha, S.; Ayyangar, Komanduri M.; Shen, Bin; Saw, Cheng B.

    2001-01-01

    Modern radiotherapy techniques involve complex field arrangements using conformal and intensity modulated radiation that requires three dimensional treatment planning. The verification of these plans poses even more challenge. In 1984, Gore et al., proposed that ferrous gel dosimeters combined with magnetic resonance imaging (MRI) could be used to measure three dimensional radiation dose distributions. Since then, there has been much interest in the development of gel dosimetry to aid the determination of three dimensional dose distributions during field arrangements. In this work, preparation and study of the MR characteristics of a PVA-Fx gel reported in the literature is presented

  1. Indeterminate findings on oncologic PET/CT: What difference dose PET/MRI make?

    Energy Technology Data Exchange (ETDEWEB)

    Fraum, Tyler J.; Fowler, Kathryn J.; McConathy, Jonathan; Dehdashti, Farokh [Mallinckrodt Institute of Radiology, Washington University School of Medicine, Saint Louis (United States)

    2016-12-15

    Positron emission tomography/computed tomography (PET/CT) with 2-deoxy-2-[{sup 18}F]fluoro-D-glucose (FDG) has become the standard of care for the initial staging and subsequent treatment response assessment of many different malignancies. Despite this success, PET/CT is often supplemented by MRI to improve assessment of local tumor invasion and to facilitate detection of lesions in organs with high background FDG uptake. Consequently, PET/MRI has the potential to expand the clinical value of PET examinations by increasing reader certainty and reducing the need for subsequent imaging. This study evaluates the ability of FDG-PET/MRI to clarify findings initially deemed indeterminate on clinical FDG-PET/CT studies. A total of 190 oncology patients underwent whole-body PET/CT, immediately followed by PET/MRI utilizing the same FDG administration. Each PET/CT was interpreted by our institution's nuclear medicine service as a standard-of-care clinical examination. Review of these PET/CT reports identified 31 patients (16 %) with indeterminate findings. Two readers evaluated all 31 PET/CT studies, followed by the corresponding PET/MRI studies. A consensus was reached for each case, and changes in interpretation directly resulting from PET/MRI review were recorded. Interpretations were then correlated with follow-up imaging, pathology results, and other diagnostic studies. In 18 of 31 cases with indeterminate findings on PET/CT, PET/MRI resulted in a more definitive interpretation by facilitating the differentiation of infection/inflammation from malignancy (15/18), the accurate localization of FDG-avid lesions (2/18), and the characterization of incidental non-FDG-avid solid organ lesions (1/18). Explanations for improved reader certainty with PET/MRI included the superior soft tissue contrast of MRI and the ability to assess cellular density with diffusion-weighted imaging. The majority (12/18) of such cases had an appropriate standard of reference; in all 12 cases

  2. Indeterminate findings on oncologic PET/CT: What difference dose PET/MRI make?

    International Nuclear Information System (INIS)

    Fraum, Tyler J.; Fowler, Kathryn J.; McConathy, Jonathan; Dehdashti, Farokh

    2016-01-01

    Positron emission tomography/computed tomography (PET/CT) with 2-deoxy-2-["1"8F]fluoro-D-glucose (FDG) has become the standard of care for the initial staging and subsequent treatment response assessment of many different malignancies. Despite this success, PET/CT is often supplemented by MRI to improve assessment of local tumor invasion and to facilitate detection of lesions in organs with high background FDG uptake. Consequently, PET/MRI has the potential to expand the clinical value of PET examinations by increasing reader certainty and reducing the need for subsequent imaging. This study evaluates the ability of FDG-PET/MRI to clarify findings initially deemed indeterminate on clinical FDG-PET/CT studies. A total of 190 oncology patients underwent whole-body PET/CT, immediately followed by PET/MRI utilizing the same FDG administration. Each PET/CT was interpreted by our institution's nuclear medicine service as a standard-of-care clinical examination. Review of these PET/CT reports identified 31 patients (16 %) with indeterminate findings. Two readers evaluated all 31 PET/CT studies, followed by the corresponding PET/MRI studies. A consensus was reached for each case, and changes in interpretation directly resulting from PET/MRI review were recorded. Interpretations were then correlated with follow-up imaging, pathology results, and other diagnostic studies. In 18 of 31 cases with indeterminate findings on PET/CT, PET/MRI resulted in a more definitive interpretation by facilitating the differentiation of infection/inflammation from malignancy (15/18), the accurate localization of FDG-avid lesions (2/18), and the characterization of incidental non-FDG-avid solid organ lesions (1/18). Explanations for improved reader certainty with PET/MRI included the superior soft tissue contrast of MRI and the ability to assess cellular density with diffusion-weighted imaging. The majority (12/18) of such cases had an appropriate standard of reference; in all 12 cases, the

  3. Implementation of spot scanning dose optimization and dose calculation for helium ions in Hyperion

    Energy Technology Data Exchange (ETDEWEB)

    Fuchs, Hermann, E-mail: hermann.fuchs@meduniwien.ac.at [Department of Radiation Oncology, Division of Medical Radiation Physics, Medical University of Vienna/AKH Vienna, Vienna 1090, Austria and Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna, Vienna 1090 (Austria); Alber, Markus [Department for Oncology, Aarhus University Hospital, Aarhus 8000 (Denmark); Schreiner, Thomas [PEG MedAustron, Wiener Neustadt 2700 (Austria); Georg, Dietmar [Department of Radiation Oncology, Division of Medical Radiation Physics, Medical University of Vienna/AKH Vienna, Vienna 1090 (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna, Vienna 1090 (Austria); Comprehensive Cancer Center, Medical University of Vienna/AKH Vienna, Vienna 1090 (Austria)

    2015-09-15

    Purpose: Helium ions ({sup 4}He) may supplement current particle beam therapy strategies as they possess advantages in physical dose distribution over protons. To assess potential clinical advantages, a dose calculation module accounting for relative biological effectiveness (RBE) was developed and integrated into the treatment planning system Hyperion. Methods: Current knowledge on RBE of {sup 4}He together with linear energy transfer considerations motivated an empirical depth-dependent “zonal” RBE model. In the plateau region, a RBE of 1.0 was assumed, followed by an increasing RBE up to 2.8 at the Bragg-peak region, which was then kept constant over the fragmentation tail. To account for a variable proton RBE, the same model concept was also applied to protons with a maximum RBE of 1.6. Both RBE models were added to a previously developed pencil beam algorithm for physical dose calculation and included into the treatment planning system Hyperion. The implementation was validated against Monte Carlo simulations within a water phantom using γ-index evaluation. The potential benefits of {sup 4}He based treatment plans were explored in a preliminary treatment planning comparison (against protons) for four treatment sites, i.e., a prostate, a base-of-skull, a pediatric, and a head-and-neck tumor case. Separate treatment plans taking into account physical dose calculation only or using biological modeling were created for protons and {sup 4}He. Results: Comparison of Monte Carlo and Hyperion calculated doses resulted in a γ{sub mean} of 0.3, with 3.4% of the values above 1 and γ{sub 1%} of 1.5 and better. Treatment plan evaluation showed comparable planning target volume coverage for both particles, with slightly increased coverage for {sup 4}He. Organ at risk (OAR) doses were generally reduced using {sup 4}He, some by more than to 30%. Improvements of {sup 4}He over protons were more pronounced for treatment plans taking biological effects into account. All

  4. Dose-dependent transitions in mechanisms of toxicity: case studies

    International Nuclear Information System (INIS)

    Slikker, William; Andersen, Melvin E.; Bogdanffy, Matthew S.; Bus, James S.; Cohen, Steven D.; Conolly, Rory B.; David, Raymond M.; Doerrer, Nancy G.; Dorman, David C.; Gaylor, David W.; Hattis, Dale; Rogers, John M.; Setzer, R. Woodrow; Swenberg, James A.; Wallace, Kendall

    2004-01-01

    Experience with dose response and mechanisms of toxicity has shown that multiple mechanisms may exist for a single agent along the continuum of the full dose-response curve. It is highly likely that critical, limiting steps in any given mechanistic pathway may become overwhelmed with increasing exposures, signaling the emergence of new modalities of toxic tissue injury at these higher doses. Therefore, dose-dependent transitions in principal mechanisms of toxicity may occur, and could have significant impact on the interpretation of reference data sets for risk assessment. To illustrate the existence of dose-dependent transitions in mechanisms of toxicity, a group of academic, government, and industry scientists, formed under the leadership of the ILSI Health and Environmental Sciences Institute (HESI), developed a series of case studies. These case studies included acetaminophen, butadiene, ethylene glycol, formaldehyde, manganese, methylene chloride, peroxisome proliferator-activated receptor (PPAR), progesterone/hydroxyflutamide, propylene oxide, vinyl acetate, vinyl chloride, vinylidene chloride, and zinc. The case studies formed the basis for technical discourse at two scientific workshops in 2003

  5. Pharmacokinetics of a telmisartan/rosuvastatin fixed-dose combination: a single-dose, randomized, open-label, 2-period crossover study in healthy Korean subjects.

    Science.gov (United States)

    Chae, Dong Woo; Son, Mijeong; Kim, Yukyung; Son, Hankil; Jang, Seong Bok; Seo, Jeong Min; Nam, Su Youn; Park, Kyungsoo

    2015-10-01

    As hypertension and dyslipidemia are frequent comorbidities, antihypertensive drugs and lipid-lowering agents are often prescribed together for their treatment. Telmisartan and rosuvastatin are widely used together to treat hypertension and dyslipidemia. A combination formulation of these two drugs would improve patient compliance due to ease of dosing. The purpose of this study was to assess bioequivalence of single-dose administration of a newly-developed fixed-dose combination (FDC) tablet containing telmisartan/rosuvastatin 80/20 mg (test treatment) and coadministration of a telmisartan 80-mg tablet and a rosuvastatin 20-mg tablet (reference treatment) in healthy Korean male volunteers. This was a single-dose, randomized, open-label, 2-period crossover study enrolling healthy males aged 20 - 50 years with BMI between 18.5 and 25 kg/m2. Each subject received a single dose of the reference and test treatments with a 14-day washout period. Blood sampling was performed at prespecified intervals for up to 72 hours after dosing. Primary pharmacokinetic parameters were Cmax, AUClast, and AUC0-∞ of telmisartan, rosuvastatin, and N-desmethyl rosuvastatin. Bioequivalence was assessed by determining whether the 90% confidence intervals (CIs) of the geometric mean ratios (test treatment/reference treatment) of these parameters were within the standard range of 80% to 125%. Adverse events were monitored via regular interviews with the subjects and by physical examinations. 60 subjects were enrolled and 55 completed the study. The 90% CIs of the geometric mean ratios of Cmax, AUClast, and AUC00-∞ were 0.9262-1.1498, 0.9294-1.0313, and 0.9312-1.0320 for telmisartan, 0.9041-1.0428, 0.9262-1.0085, and 0.9307-1.0094 for rosuvastatin, and 0.8718-1.0022, 0.8901-0.9904, and 0.8872-0.9767 for N-desmethyl rosuvastatin, respectively. There was no statistical difference in the incidence of adverse events (AEs) (all of which were mild or moderate) between the reference and test

  6. From Hiroshima to Chernobyl: epidemiological findings, uncertainties and perceptions

    International Nuclear Information System (INIS)

    Burkart, W.; Hendry, J.

    2003-01-01

    The effects on persons of ionizing radiation can be quantified on three major pathways. At the present time, it is not possible to understand fully the basis of mechanistic principles of the interaction of ionizing radiation with the critical macromolecules, i.e. DNA, cell nuclei, cells, and body tissue, also because of the stochastic methods to be employed, the many factors influencing the situation, and the complex radiobiological mechanisms. Studies of the effects of radiation on animals, among other things, allow teratogenic changes and carcinogenicity to be studied as a function of many variables, such as the radiation dose and dose rates. However, these findings can be extrapolated to the situation in humans only to a limited extent. Even tighter constraints apply to the extrapolation of possible effects of low doses. On the whole, these studies generate important findings. The most important findings about the health effects of ionizing radiation to this day have arisen from statistical correlations of radiation exposures and the incidence of diseases in exposed groups of the population. The article presents the main results of studies conducted in the past and of ongoing studies, and cites remaining uncertainties. These uncertainties especially relate to the effects of low radiation levels. In this field, substantial problems exist, among other things, in the interpretation of data on the basis of varying environmental factors and the resultant absence of uniform conditions for evaluation and extrapolation to the low-dose range. (orig.) [de

  7. Poster - 08: Preliminary Investigation into Collapsed-Cone based Dose Calculations for COMS Eye Plaques

    International Nuclear Information System (INIS)

    Morrison, Hali; Menon, Geetha; Sloboda, Ron

    2016-01-01

    Purpose: To investigate the accuracy of model-based dose calculations using a collapsed-cone algorithm for COMS eye plaques loaded with I-125 seeds. Methods: The Nucletron SelectSeed 130.002 I-125 seed and the 12 mm COMS eye plaque were incorporated into a research version of the Oncentra® Brachy v4.5 treatment planning system which uses the Advanced Collapsed-cone Engine (ACE) algorithm. Comparisons of TG-43 and high-accuracy ACE doses were performed for a single seed in a 30×30×30 cm 3 water box, as well as with one seed in the central slot of the 12 mm COMS eye plaque. The doses along the plaque central axis (CAX) were used to calculate the carrier correction factor, T(r), and were compared to tabulated and MCNP6 simulated doses for both the SelectSeed and IsoAid IAI-125A seeds. Results: The ACE calculated dose for the single seed in water was on average within 0.62 ± 2.2% of the TG-43 dose, with the largest differences occurring near the end-welds. The ratio of ACE to TG-43 calculated doses along the CAX (T(r)) of the 12 mm COMS plaque for the SelectSeed was on average within 3.0% of previously tabulated data, and within 2.9% of the MCNP6 simulated values. The IsoAid and SelectSeed T(r) values agreed within 0.3%. Conclusions: Initial comparisons show good agreement between ACE and MC doses for a single seed in a 12 mm COMS eye plaque; more complicated scenarios are being investigated to determine the accuracy of this calculation method.

  8. Poster - 08: Preliminary Investigation into Collapsed-Cone based Dose Calculations for COMS Eye Plaques

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, Hali; Menon, Geetha; Sloboda, Ron [Cross Cancer Institute, Edmonton, AB, and University of Alberta, Edmonton, AB, Cross Cancer Institute, Edmonton, AB, and University of Alberta, Edmonton, AB, Cross Cancer Institute, Edmonton, AB, and University of Alberta, Edmonton, AB (Canada)

    2016-08-15

    Purpose: To investigate the accuracy of model-based dose calculations using a collapsed-cone algorithm for COMS eye plaques loaded with I-125 seeds. Methods: The Nucletron SelectSeed 130.002 I-125 seed and the 12 mm COMS eye plaque were incorporated into a research version of the Oncentra® Brachy v4.5 treatment planning system which uses the Advanced Collapsed-cone Engine (ACE) algorithm. Comparisons of TG-43 and high-accuracy ACE doses were performed for a single seed in a 30×30×30 cm{sup 3} water box, as well as with one seed in the central slot of the 12 mm COMS eye plaque. The doses along the plaque central axis (CAX) were used to calculate the carrier correction factor, T(r), and were compared to tabulated and MCNP6 simulated doses for both the SelectSeed and IsoAid IAI-125A seeds. Results: The ACE calculated dose for the single seed in water was on average within 0.62 ± 2.2% of the TG-43 dose, with the largest differences occurring near the end-welds. The ratio of ACE to TG-43 calculated doses along the CAX (T(r)) of the 12 mm COMS plaque for the SelectSeed was on average within 3.0% of previously tabulated data, and within 2.9% of the MCNP6 simulated values. The IsoAid and SelectSeed T(r) values agreed within 0.3%. Conclusions: Initial comparisons show good agreement between ACE and MC doses for a single seed in a 12 mm COMS eye plaque; more complicated scenarios are being investigated to determine the accuracy of this calculation method.

  9. Paediatric cardiac CT examinations: impact of the iterative reconstruction method ASIR on image quality--preliminary findings.

    Science.gov (United States)

    Miéville, Frédéric A; Gudinchet, François; Rizzo, Elena; Ou, Phalla; Brunelle, Francis; Bochud, François O; Verdun, Francis R

    2011-09-01

    Radiation dose exposure is of particular concern in children due to the possible harmful effects of ionizing radiation. The adaptive statistical iterative reconstruction (ASIR) method is a promising new technique that reduces image noise and produces better overall image quality compared with routine-dose contrast-enhanced methods. To assess the benefits of ASIR on the diagnostic image quality in paediatric cardiac CT examinations. Four paediatric radiologists based at two major hospitals evaluated ten low-dose paediatric cardiac examinations (80 kVp, CTDI(vol) 4.8-7.9 mGy, DLP 37.1-178.9 mGy·cm). The average age of the cohort studied was 2.6 years (range 1 day to 7 years). Acquisitions were performed on a 64-MDCT scanner. All images were reconstructed at various ASIR percentages (0-100%). For each examination, radiologists scored 19 anatomical structures using the relative visual grading analysis method. To estimate the potential for dose reduction, acquisitions were also performed on a Catphan phantom and a paediatric phantom. The best image quality for all clinical images was obtained with 20% and 40% ASIR (p ASIR above 50%, image quality significantly decreased (p ASIR, a strong noise-free appearance of the structures reduced image conspicuity. A potential for dose reduction of about 36% is predicted for a 2- to 3-year-old child when using 40% ASIR rather than the standard filtered back-projection method. Reconstruction including 20% to 40% ASIR slightly improved the conspicuity of various paediatric cardiac structures in newborns and children with respect to conventional reconstruction (filtered back-projection) alone.

  10. An overview of industrial and organisational psychology research in South Africa: A preliminary study

    Directory of Open Access Journals (Sweden)

    Dries Schreuder

    2010-10-01

    Research purpose: The purpose of this study was to explore general research trends in the field of industrial and organisational psychology in South Africa from 1950 to 2008. Motivation for study: Research in the field tends to be influenced by either the changing needs of business or the occupational or personal fields of interest of academics, which often lead to an overemphasis on specific subdisciplines at the expense of others. This research aims to critically review dominant trends in the research focus areas in the field, in the light of present challenges in the changing work context. Recommendations are also made for possible future research. Research design, approach and method: A broad systematic review was carried out to analyse documented published and accredited South African research in the field (n = 2501. Main findings: Although there has been a proportional decline in personnel psychology research since 1990, there has been a proportional increase in both organisational psychology and employee wellness research since 1980 and 1990, respectively. Some areas of the industrial and organisational psychology field appear to be consistently under-researched. Practical implications: The insights derived from the findings can be used by academia and researchers in the field to plan future research initiatives. Contribution/value-add: The findings provide preliminary insights that contribute to the body of knowledge concerned with the industrial and organisational psychology field in the South African context.

  11. Preliminary study and Identification of insects' species of forensic ...

    African Journals Online (AJOL)

    The proper identification of the insect and arthropod species of forensic importance is the most crucial element in the field of forensic entomology. The main objective in this study was the identification of insects' species of forensic importance in Urmia (37°, 33 N. and 45°, 4, 45 E.) and establishment of a preliminary ...

  12. Preliminary study on chicken feather protein-based wood adhesives

    Science.gov (United States)

    Zehui Jiang; Daochun Qin; Chung-Yun Hse; Monlin Kuo; Zhaohui Luo; Ge Wang; Yan Yu

    2008-01-01

    The objective of this preliminary study was to partially replace phenol in the synthesis of phenol-formaldehyde resin with feather protein. Feather protein–based resins, which contained one part feather protein and two parts phenol, were formulated under the conditions of two feather protein hydrolysis methods (with and without presence of phenol during...

  13. Study on dose distribution of therapeutic proton beams with prompt gamma measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. W. [National Cancer Center, Seoul (Korea, Republic of); Min, C. H.; Kim, C. H.; Kim, D. K.; Yoon, M. Y. [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2007-03-15

    The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma distribution was compared to the dose distribution measured by an ionization chamber at three different energies of 100, 150, 200 MeV's. The two distributions were well correlated within 1-2 mm. The effect of high-energy neutron appeared as blurred distribution near the distal dose falloff at the energy of 200 MeV. We then tested the PGS shielding design by adding additional layer of paraffin plates outside of the PGS, and found that fast neutrons significantly affect the background level. But the location of the dose fall-off was nearly coincident. The analysis of gamma energy spectrum showed that cut-off energy in gamma counting can be adjusted to enhance the signal to noise ratio. Further the ATOM phantom, which has similar tissue structure to human, was used to investigate the gamma distribution for the case of inhomogeneous matter. The location of dose falloff region was found to be well defined as for water phantom. Next an actual therapy beam, which was produced by the double scattering method, was used, for which the dose falloff by the gamma distribution was completely wiped out by background neutrons. It is not

  14. Pulse-Dose Radiofrequency in Athletic Pubalgia: Preliminary Results.

    Science.gov (United States)

    Masala, Salvatore; Fiori, Roberto; Raguso, Mario; Ojango, Christine; Morini, Marco; Cuzzolino, Alessandro; Calabria, Eros; Simonetti, Giovanni

    2017-05-01

    Chronic pubalgia affects around 10% of athletes. To determine the role of pulse-dose radiofrequency (PDRF) in athletes with chronic pubalgia and investigate the causes with imaging. Prospective nonrandomized single-group study. PDRF was performed on 32 patients with a chronic pain that had been refractory to conservative therapies during the last 3 mo. The genital branches of the genitofemoral, ilioinguinal, and iliohypogastric nerves and the obturator nerve were the goals of treatment. A 10-cm, 20-gauge cannula was inserted with a percutaneous access on the upper and lower edges of the iliopubic branch. After the spindle was removed, a radiofrequency needle with a 10-mm "active tip" was inserted. The radiofrequency technique was performed with 1200 pulses at 45 V and 20-ms duration, followed by a 480-ms silent phase. The follow-up with a clinical examination was performed at 1, 3, 6, and 9 mo after the procedure. During the follow-up visits, the patients were asked to rate their pain on a 0-10 VAS scale. All of the enrolled patients completed the study. Mean VAS score before the treatment was 8.4 ± 0.6. Twenty-four patients had a reduction of pain VAS scores more than 50% during all follow-up visits and started training and physiotherapy in the days after the radiofrequency procedure. Six patients, each treated 2 times, had a reduction more than 50% of VAS scores and could start training and physiotherapy only after the 2nd procedure. One patient had no pain relief with 2 treatments. Pain intensity decreased up to 9 mo in 31 patients (mean VAS scores 3.4 ± 0.5 at 6 mo and 3.8 ± 0.9 at 9 mo). No complications were observed. PDRF is an effective and safe technique in management of chronic pubalgia in athletes.

  15. Thyroid cancer incidence among Swedish patients exposed to diagnostic doses of iodine-131: A preliminary report

    International Nuclear Information System (INIS)

    Hall, P.E.

    1996-01-01

    The level of risk associated with I-131 is not well defined but appears lower than equivalent doses of x-rays. To provide quantitative data on the risk of thyroid cancer following I-131 exposure, 34,104 patients surviving ≅ 5 years after I-131 administration between 1950-69 for diagnostic purposes were studied. The mean thyroid dose was estimated to be 1.1 Gy (range 0-40.5). A significantly increased risk of a subsequent thyroid cancer was found, however, the excess rates were based entirely on patients referred because of a suspicion of a thyroid tumor. There was no suggestion of an increasing risk with increasing dose or time since exposure. No significant excess risk was found among those less than 20 years of age at exposure. The absence of a risk among those over age 20 is consistent with studies of A-bomb survivors and implies that any type of exposure to ionizing radiation later in life is associated with a minimal cancer risk. (author). 23 refs, 4 tabs

  16. Thyroid cancer incidence among Swedish patients exposed to diagnostic doses of iodine-131: A preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Hall, P E [Karolinska Hospital, Stockhom (Sweden). Dept. of General Oncology; Holm, L E [National Inst. of Public Health, Stockholm (Sweden)

    1996-08-01

    The level of risk associated with I-131 is not well defined but appears lower than equivalent doses of x-rays. To provide quantitative data on the risk of thyroid cancer following I-131 exposure, 34,104 patients surviving {approx_equal} 5 years after I-131 administration between 1950-69 for diagnostic purposes were studied. The mean thyroid dose was estimated to be 1.1 Gy (range 0-40.5). A significantly increased risk of a subsequent thyroid cancer was found, however, the excess rates were based entirely on patients referred because of a suspicion of a thyroid tumor. There was no suggestion of an increasing risk with increasing dose or time since exposure. No significant excess risk was found among those less than 20 years of age at exposure. The absence of a risk among those over age 20 is consistent with studies of A-bomb survivors and implies that any type of exposure to ionizing radiation later in life is associated with a minimal cancer risk. (author). 23 refs, 4 tabs.

  17. A preliminary conceptual design study for Korean fusion DEMO reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Keeman, E-mail: kkeeman@nfri.re.kr [National Fusion Research Institute, 169-148 Gwahak-ro, Daejeon 305-806 (Korea, Republic of); Kim, Hyoung Chan; Oh, Sangjun; Lee, Young Seok; Yeom, Jun Ho; Im, Kihak; Lee, Gyung-Su [National Fusion Research Institute, 169-148 Gwahak-ro, Daejeon 305-806 (Korea, Republic of); Neilson, George; Kessel, Charles; Brown, Thomas; Titus, Peter [Princeton Plasma Physics Laboratory, Princeton University, Princeton, NJ 08543 (United States)

    2013-10-15

    Highlights: ► Perform a preliminary conceptual study for a steady-state Korean DEMO reactor. ► Present design guidelines and requirements of Korean DEMO reactor. ► Present a preliminary design of TF (toroidal field) and CS (central solenoid) magnet. ► Present a preliminary result of the radial build scheme of Korean DEMO reactor. -- Abstract: As the ITER is being constructed, there is a growing anticipation for an earlier realization of fusion energy, so called fast-track approach. Korean strategy for fusion energy can be regarded as a fast-track approach and one special concept discussed in this paper is a two-stage development plan. At first, a steady-state Korean DEMO Reactor (K-DEMO) is designed not only to demonstrate a net electricity generation and a self-sustained tritium cycle, but also to be used as a component test facility. Then, at its second stage, a major upgrade is carried out by replacing in-vessel components in order to show a net electric generation on the order of 300 MWe and the competitiveness in cost of electricity (COE). The major radius is designed to be just below 6.5 m, considering practical engineering feasibilities. By using high performance Nb{sub 3}Sn-based superconducting cable currently available, high magnetic field at the plasma center above 8 T can be achieved. A design concept for TF magnets and radial builds for the K-DEMO considering a vertical maintenance scheme, are presented together with preliminary design parameters.

  18. Work plan for the Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    1989-12-01

    The primary objective of the Hanford Environmental Dose Reconstruction (HEDR) Project is to estimate the radiation doses that populations could have received from nuclear operations at the Hanford Site since 1944, with descriptions of uncertainties inherent in such estimates. The secondary objective is to make project records--information that HEDR staff members used to estimate radiation doses--available to the public. Preliminary dose estimates for a limited geographic area and time period, certain radionuclides, and certain populations are planned to be available in 1990; complete results are planned to be reported in 1993. Project reports and references used in the reports are available to the public in the DOE Public Reading Room in Richland, Washington. Project progress is documented in monthly reports, which are also available to the public in the DOE Public Reading Room.

  19. Towards more reliable automated multi-dose dispensing: retrospective follow-up study on medication dose errors and product defects.

    Science.gov (United States)

    Palttala, Iida; Heinämäki, Jyrki; Honkanen, Outi; Suominen, Risto; Antikainen, Osmo; Hirvonen, Jouni; Yliruusi, Jouko

    2013-03-01

    To date, little is known on applicability of different types of pharmaceutical dosage forms in an automated high-speed multi-dose dispensing process. The purpose of the present study was to identify and further investigate various process-induced and/or product-related limitations associated with multi-dose dispensing process. The rates of product defects and dose dispensing errors in automated multi-dose dispensing were retrospectively investigated during a 6-months follow-up period. The study was based on the analysis of process data of totally nine automated high-speed multi-dose dispensing systems. Special attention was paid to the dependence of multi-dose dispensing errors/product defects and pharmaceutical tablet properties (such as shape, dimensions, weight, scored lines, coatings, etc.) to profile the most suitable forms of tablets for automated dose dispensing systems. The relationship between the risk of errors in dose dispensing and tablet characteristics were visualized by creating a principal component analysis (PCA) model for the outcome of dispensed tablets. The two most common process-induced failures identified in the multi-dose dispensing are predisposal of tablet defects and unexpected product transitions in the medication cassette (dose dispensing error). The tablet defects are product-dependent failures, while the tablet transitions are dependent on automated multi-dose dispensing systems used. The occurrence of tablet defects is approximately twice as common as tablet transitions. Optimal tablet preparation for the high-speed multi-dose dispensing would be a round-shaped, relatively small/middle-sized, film-coated tablet without any scored line. Commercial tablet products can be profiled and classified based on their suitability to a high-speed multi-dose dispensing process.

  20. Topical administration of regorafenib eye drops: phase I dose-escalation study in healthy volunteers.

    Science.gov (United States)

    Zimmermann, Torsten; Höchel, Joachim; Becka, Michael; Boettger, Michael K; Rohde, Beate; Schug, Barbara; Kunert, Kathleen S; Donath, Frank

    2018-05-01

    Regorafenib is a multikinase inhibitor under investigation for use in neovascular age-related macular degeneration. In this phase I study, regorafenib eye drops were administered to healthy volunteers to provide information on safety, tolerability and systemic exposure. This was a single-centre, randomized, double-masked, parallel-group, dose-escalation, placebo-controlled study. Subjects received regorafenib eye drops (30 mg ml -1 , 25 μl) as a 0.75 mg single dose (Cohort 1), 0.75 mg twice daily (bid) or thrice daily (tid) over 14 days (Cohorts 2 and 3, respectively), 1.5 mg tid unilaterally for 3 days, then bilaterally for up to 14 days (Cohort 4), or placebo. Plasma samples were taken to estimate systemic exposure. Safety and functional assessments were performed throughout the study. Thirty-six subjects received regorafenib and 12 received placebo. Regorafenib was safe and well tolerated over the dose range. No pathological changes occurred in the anterior, vitreous or posterior eye compartments. Mild eyelid redness, oedema and conjunctival hyperaemia were observed across all regorafenib cohorts; these were comparable with the effects seen with placebo. Predominant symptoms were blurred vision in the active and placebo groups. Systemic safety evaluations showed no clinically relevant findings. Absolute systemic exposure after multiple administrations of regorafenib eye drops at a dose of 0.75 mg was 600-700-fold lower than after multiple oral administration of 160 mg day -1 , the dose approved in cancer indications. These results indicate a favourable safety and tolerability profile of regorafenib eye drops up to 30 mg ml -1 tid for use in clinical studies. © 2018 The Authors. British Journal of Clinical Pharmacology published by John Wiley & Sons Ltd on behalf of British Pharmacological Society.