Sample records for preclinical tomograph based

  1. Fully 3D tomographic reconstruction by Monte Carlo simulation of the system matrix in preclinical PET with iodine 124

    International Nuclear Information System (INIS)

    Moreau, Matthieu

    2014-01-01

    Immuno-PET imaging can be used to assess the pharmacokinetic in radioimmunotherapy. When using iodine-124, PET quantitative imaging is limited by physics-based degrading factors within the detection system and the object, such as the long positron range in water and the complex spectrum of gamma photons. The objective of this thesis was to develop a fully 3D tomographic reconstruction method (S(MC)2PET) using Monte Carlo simulations for estimating the system matrix, in the context of preclinical imaging with iodine-124. The Monte Carlo simulation platform GATE was used for that respect. Several complexities of system matrices were calculated, with at least a model of the PET system response function. Physics processes in the object was either neglected or taken into account using a precise or a simplified object description. The impact of modelling refinement and statistical variance related to the system matrix elements was evaluated on final reconstructed images. These studies showed that a high level of complexity did not always improve qualitative and quantitative results, owing to the high-variance of the associated system matrices. (author)

  2. Tomographs based on non-conventional radiation sources and methods

    International Nuclear Information System (INIS)

    Barbuzza, R.; Fresno, M. del; Venere, Marcelo J.; Clausse, Alejandro; Moreno, C.

    2000-01-01

    Computer techniques for tomographic reconstruction of objects X-rayed with a compact plasma focus (PF) are presented. The implemented reconstruction algorithms are based on stochastic searching of solutions of Radon equation, using Genetic Algorithms and Monte Carlo methods. Numerical experiments using actual projections were performed concluding the feasibility of the application of both methods in tomographic reconstruction problem. (author)

  3. Performance evaluation of the CT component of the IRIS PET/CT preclinical tomograph

    Energy Technology Data Exchange (ETDEWEB)

    Panetta, Daniele [CNR Institute of Clinical Physiology (IFC-CNR), v. G. Moruzzi 1, I-56124 Pisa (Italy); Belcari, Nicola [Department of Physics “E. Fermi”, University of Pisa, L.go B. Pontecorvo 3, I-56127 Pisa (Italy); Tripodi, Maria [CNR Institute of Clinical Physiology (IFC-CNR), v. G. Moruzzi 1, I-56124 Pisa (Italy); Burchielli, Silvia [Fondazione CNR/Toscana “G. Monasterio” – FTGM, v. G. Moruzzi 1, I-56124 Pisa (Italy); Salvadori, Piero A. [CNR Institute of Clinical Physiology (IFC-CNR), v. G. Moruzzi 1, I-56124 Pisa (Italy); Del Guerra, Alberto [Department of Physics “E. Fermi”, University of Pisa, L.go B. Pontecorvo 3, I-56127 Pisa (Italy)

    2016-01-01

    In this paper, we evaluate the physical performance of the CT component of the IRIS scanner, a novel combined PET/CT scanner for preclinical imaging. The performance assessment is based on phantom measurement for the determination of image quality parameters (spatial resolution, linearity, geometric accuracy, contrast to noise ratio) and reproducibility in dynamic (4D) imaging. The CTDI{sub 100} has been measured free in air with a pencil ionization chamber, and the animal dose was calculated using Monte Carlo derived conversion factors taken from the literature. The spatial resolution at the highest quality protocol was 6.9 lp/mm at 10% of the MTF, using the smallest reconstruction voxel size of 58.8 μm. The accuracy of the reconstruction voxel size was within 0.1%. The linearity of the CT numbers as a function of the concentration of iodine was very good, with R{sup 2}>0.996 for all the tube voltages. The animal dose depended strongly on the scanning protocol, ranging from 158 mGy for the highest quality protocol (2 min, 80 kV) to about 12 mGy for the fastest protocol (7.3 s, 80 kV). In 4D dynamic modality, the maximum scanning rate reached was 3.1 frames per minute, using a short-scan protocol with 7.3 s of scan time per frame at the isotropic voxel size of 235 μm. The reproducibility of the system was high throughout the 10 frames acquired in dynamic modality, with a standard deviation of the CT values of all frames <8 HU and an average spatial reproducibility within 30% of the voxel size across all the field of view. Example images obtained during animal experiments are also shown.

  4. Performance evaluation of the CT component of the IRIS PET/CT preclinical tomograph

    Science.gov (United States)

    Panetta, Daniele; Belcari, Nicola; Tripodi, Maria; Burchielli, Silvia; Salvadori, Piero A.; Del Guerra, Alberto

    2016-01-01

    In this paper, we evaluate the physical performance of the CT component of the IRIS scanner, a novel combined PET/CT scanner for preclinical imaging. The performance assessment is based on phantom measurement for the determination of image quality parameters (spatial resolution, linearity, geometric accuracy, contrast to noise ratio) and reproducibility in dynamic (4D) imaging. The CTDI100 has been measured free in air with a pencil ionization chamber, and the animal dose was calculated using Monte Carlo derived conversion factors taken from the literature. The spatial resolution at the highest quality protocol was 6.9 lp/mm at 10% of the MTF, using the smallest reconstruction voxel size of 58.8 μm. The accuracy of the reconstruction voxel size was within 0.1%. The linearity of the CT numbers as a function of the concentration of iodine was very good, with R2>0.996 for all the tube voltages. The animal dose depended strongly on the scanning protocol, ranging from 158 mGy for the highest quality protocol (2 min, 80 kV) to about 12 mGy for the fastest protocol (7.3 s, 80 kV). In 4D dynamic modality, the maximum scanning rate reached was 3.1 frames per minute, using a short-scan protocol with 7.3 s of scan time per frame at the isotropic voxel size of 235 μm. The reproducibility of the system was high throughout the 10 frames acquired in dynamic modality, with a standard deviation of the CT values of all frames <8 HU and an average spatial reproducibility within 30% of the voxel size across all the field of view. Example images obtained during animal experiments are also shown.

  5. Performance evaluation of the CT component of the IRIS PET/CT preclinical tomograph

    International Nuclear Information System (INIS)

    Panetta, Daniele; Belcari, Nicola; Tripodi, Maria; Burchielli, Silvia; Salvadori, Piero A.; Del Guerra, Alberto

    2016-01-01

    In this paper, we evaluate the physical performance of the CT component of the IRIS scanner, a novel combined PET/CT scanner for preclinical imaging. The performance assessment is based on phantom measurement for the determination of image quality parameters (spatial resolution, linearity, geometric accuracy, contrast to noise ratio) and reproducibility in dynamic (4D) imaging. The CTDI_1_0_0 has been measured free in air with a pencil ionization chamber, and the animal dose was calculated using Monte Carlo derived conversion factors taken from the literature. The spatial resolution at the highest quality protocol was 6.9 lp/mm at 10% of the MTF, using the smallest reconstruction voxel size of 58.8 μm. The accuracy of the reconstruction voxel size was within 0.1%. The linearity of the CT numbers as a function of the concentration of iodine was very good, with R"2>0.996 for all the tube voltages. The animal dose depended strongly on the scanning protocol, ranging from 158 mGy for the highest quality protocol (2 min, 80 kV) to about 12 mGy for the fastest protocol (7.3 s, 80 kV). In 4D dynamic modality, the maximum scanning rate reached was 3.1 frames per minute, using a short-scan protocol with 7.3 s of scan time per frame at the isotropic voxel size of 235 μm. The reproducibility of the system was high throughout the 10 frames acquired in dynamic modality, with a standard deviation of the CT values of all frames <8 HU and an average spatial reproducibility within 30% of the voxel size across all the field of view. Example images obtained during animal experiments are also shown.

  6. CCD-camera-based diffuse optical tomography to study ischemic stroke in preclinical rat models

    Science.gov (United States)

    Lin, Zi-Jing; Niu, Haijing; Liu, Yueming; Su, Jianzhong; Liu, Hanli

    2011-02-01

    Stroke, due to ischemia or hemorrhage, is the neurological deficit of cerebrovasculature and is the third leading cause of death in the United States. More than 80 percent of stroke patients are ischemic stroke due to blockage of artery in the brain by thrombosis or arterial embolism. Hence, development of an imaging technique to image or monitor the cerebral ischemia and effect of anti-stoke therapy is more than necessary. Near infrared (NIR) optical tomographic technique has a great potential to be utilized as a non-invasive image tool (due to its low cost and portability) to image the embedded abnormal tissue, such as a dysfunctional area caused by ischemia. Moreover, NIR tomographic techniques have been successively demonstrated in the studies of cerebro-vascular hemodynamics and brain injury. As compared to a fiberbased diffuse optical tomographic system, a CCD-camera-based system is more suitable for pre-clinical animal studies due to its simpler setup and lower cost. In this study, we have utilized the CCD-camera-based technique to image the embedded inclusions based on tissue-phantom experimental data. Then, we are able to obtain good reconstructed images by two recently developed algorithms: (1) depth compensation algorithm (DCA) and (2) globally convergent method (GCM). In this study, we will demonstrate the volumetric tomographic reconstructed results taken from tissuephantom; the latter has a great potential to determine and monitor the effect of anti-stroke therapies.

  7. Expediting model-based optoacoustic reconstructions with tomographic symmetries

    International Nuclear Information System (INIS)

    Lutzweiler, Christian; Deán-Ben, Xosé Luís; Razansky, Daniel

    2014-01-01

    Purpose: Image quantification in optoacoustic tomography implies the use of accurate forward models of excitation, propagation, and detection of optoacoustic signals while inversions with high spatial resolution usually involve very large matrices, leading to unreasonably long computation times. The development of fast and memory efficient model-based approaches represents then an important challenge to advance on the quantitative and dynamic imaging capabilities of tomographic optoacoustic imaging. Methods: Herein, a method for simplification and acceleration of model-based inversions, relying on inherent symmetries present in common tomographic acquisition geometries, has been introduced. The method is showcased for the case of cylindrical symmetries by using polar image discretization of the time-domain optoacoustic forward model combined with efficient storage and inversion strategies. Results: The suggested methodology is shown to render fast and accurate model-based inversions in both numerical simulations andpost mortem small animal experiments. In case of a full-view detection scheme, the memory requirements are reduced by one order of magnitude while high-resolution reconstructions are achieved at video rate. Conclusions: By considering the rotational symmetry present in many tomographic optoacoustic imaging systems, the proposed methodology allows exploiting the advantages of model-based algorithms with feasible computational requirements and fast reconstruction times, so that its convenience and general applicability in optoacoustic imaging systems with tomographic symmetries is anticipated

  8. Tensor-based Dictionary Learning for Dynamic Tomographic Reconstruction

    Science.gov (United States)

    Tan, Shengqi; Zhang, Yanbo; Wang, Ge; Mou, Xuanqin; Cao, Guohua; Wu, Zhifang; Yu, Hengyong

    2015-01-01

    In dynamic computed tomography (CT) reconstruction, the data acquisition speed limits the spatio-temporal resolution. Recently, compressed sensing theory has been instrumental in improving CT reconstruction from far few-view projections. In this paper, we present an adaptive method to train a tensor-based spatio-temporal dictionary for sparse representation of an image sequence during the reconstruction process. The correlations among atoms and across phases are considered to capture the characteristics of an object. The reconstruction problem is solved by the alternating direction method of multipliers. To recover fine or sharp structures such as edges, the nonlocal total variation is incorporated into the algorithmic framework. Preclinical examples including a sheep lung perfusion study and a dynamic mouse cardiac imaging demonstrate that the proposed approach outperforms the vectorized dictionary-based CT reconstruction in the case of few-view reconstruction. PMID:25779991

  9. Tensor-based dictionary learning for dynamic tomographic reconstruction

    International Nuclear Information System (INIS)

    Tan, Shengqi; Wu, Zhifang; Zhang, Yanbo; Mou, Xuanqin; Wang, Ge; Cao, Guohua; Yu, Hengyong

    2015-01-01

    In dynamic computed tomography (CT) reconstruction, the data acquisition speed limits the spatio-temporal resolution. Recently, compressed sensing theory has been instrumental in improving CT reconstruction from far few-view projections. In this paper, we present an adaptive method to train a tensor-based spatio-temporal dictionary for sparse representation of an image sequence during the reconstruction process. The correlations among atoms and across phases are considered to capture the characteristics of an object. The reconstruction problem is solved by the alternating direction method of multipliers. To recover fine or sharp structures such as edges, the nonlocal total variation is incorporated into the algorithmic framework. Preclinical examples including a sheep lung perfusion study and a dynamic mouse cardiac imaging demonstrate that the proposed approach outperforms the vectorized dictionary-based CT reconstruction in the case of few-view reconstruction. (paper)

  10. Voxel-based model construction from colored tomographic images

    International Nuclear Information System (INIS)

    Loureiro, Eduardo Cesar de Miranda

    2002-07-01

    This work presents a new approach in the construction of voxel-based phantoms that was implemented to simplify the segmentation process of organs and tissues reducing the time used in this procedure. The segmentation process is performed by painting tomographic images and attributing a different color for each organ or tissue. A voxel-based head and neck phantom was built using this new approach. The way as the data are stored allows an increasing in the performance of the radiation transport code. The program that calculates the radiation transport also works with image files. This capability allows image reconstruction showing isodose areas, under several points of view, increasing the information to the user. Virtual X-ray photographs can also be obtained allowing that studies could be accomplished looking for the radiographic techniques optimization assessing, at the same time, the doses in organs and tissues. The accuracy of the program here presented, called MCvoxEL, that implements this new approach, was tested by comparison to results from two modern and well-supported Monte Carlo codes. Dose conversion factors for parallel X-ray exposure were also calculated. (author)

  11. Development of a computerized tomographic system based on the FAN-BEAM technique

    International Nuclear Information System (INIS)

    Junqueira, M.M.; Santos, C.A.C.; Borges, J.C.

    1986-01-01

    The Nuclear Instrumentation Laboratory, at COPPE/UFRJ, concentrates its researches in the development of computerized tomographic systems, looking for applications in industrial and medical non destructive analysing techniques. In this work we have projected and constructed a tomographic prototype, based on the FAN-BEAM technique for irradiating the object under analysis. An algorithm previously developed to analyse parallel beams, was modified and adapted to the FAN-BEAM geometry. (Author) [pt

  12. A digital-signal-processor-based optical tomographic system for dynamic imaging of joint diseases

    Science.gov (United States)

    Lasker, Joseph M.

    Over the last decade, optical tomography (OT) has emerged as viable biomedical imaging modality. Various imaging systems have been developed that are employed in preclinical as well as clinical studies, mostly targeting breast imaging, brain imaging, and cancer related studies. Of particular interest are so-called dynamic imaging studies where one attempts to image changes in optical properties and/or physiological parameters as they occur during a system perturbation. To successfully perform dynamic imaging studies, great effort is put towards system development that offers increasingly enhanced signal-to-noise performance at ever shorter data acquisition times, thus capturing high fidelity tomographic data within narrower time periods. Towards this goal, I have developed in this thesis a dynamic optical tomography system that is, unlike currently available analog instrumentation, based on digital data acquisition and filtering techniques. At the core of this instrument is a digital signal processor (DSP) that collects, collates, and processes the digitized data set. Complementary protocols between the DSP and a complex programmable logic device synchronizes the sampling process and organizes data flow. Instrument control is implemented through a comprehensive graphical user interface which integrates automated calibration, data acquisition, and signal post-processing. Real-time data is generated at frame rates as high as 140 Hz. An extensive dynamic range (˜190 dB) accommodates a wide scope of measurement geometries and tissue types. Performance analysis demonstrates very low system noise (˜1 pW rms noise equivalent power), excellent signal precision (˜0.04%--0.2%) and long term system stability (˜1% over 40 min). Experiments on tissue phantoms validate spatial and temporal accuracy of the system. As a potential new application of dynamic optical imaging I present the first application of this method to use vascular hemodynamics as a means of characterizing

  13. Lamb-Wave-Based Tomographic Imaging Techniques for Hole-Edge Corrosion Monitoring in Plate Structures

    Directory of Open Access Journals (Sweden)

    Dengjiang Wang

    2016-11-01

    Full Text Available This study presents a novel monitoring method for hole-edge corrosion damage in plate structures based on Lamb wave tomographic imaging techniques. An experimental procedure with a cross-hole layout using 16 piezoelectric transducers (PZTs was designed. The A0 mode of the Lamb wave was selected, which is sensitive to thickness-loss damage. The iterative algebraic reconstruction technique (ART method was used to locate and quantify the corrosion damage at the edge of the hole. Hydrofluoric acid with a concentration of 20% was used to corrode the specimen artificially. To estimate the effectiveness of the proposed method, the real corrosion damage was compared with the predicted corrosion damage based on the tomographic method. The results show that the Lamb-wave-based tomographic method can be used to monitor the hole-edge corrosion damage accurately.

  14. Preclinical tests of an android based dietary logging application.

    Science.gov (United States)

    Kósa, István; Vassányi, István; Pintér, Balázs; Nemes, Márta; Kámánné, Krisztina; Kohut, László

    2014-01-01

    The paper describes the first, preclinical evaluation of a dietary logging application developed at the University of Pannonia, Hungary. The mobile user interface is briefly introduced. The three evaluation phases examined the completeness and contents of the dietary database and the time expenditure of the mobile based diet logging procedure. The results show that although there are substantial individual differences between various dietary databases, the expectable difference with respect to nutrient contents is below 10% on typical institutional menu list. Another important finding is that the time needed to record the meals can be reduced to about 3 minutes daily especially if the user uses set-based search. a well designed user interface on a mobile device is a viable and reliable way for a personalized lifestyle support service.

  15. Robotic Anterior and Midline Skull Base Surgery: Preclinical Investigations

    International Nuclear Information System (INIS)

    O'Malley, Bert W.; Weinstein, Gregory S.

    2007-01-01

    Purpose: To develop a minimally invasive surgical technique to access the midline and anterior skull base using the optical and technical advantages of robotic surgical instrumentation. Methods and Materials: Ten experimental procedures focusing on approaches to the nasopharynx, clivus, sphenoid, pituitary sella, and suprasellar regions were performed on one cadaver and one live mongrel dog. Both the cadaver and canine procedures were performed in an approved training facility using the da Vinci Surgical Robot. For the canine experiments, a transoral robotic surgery (TORS) approach was used, and for the cadaver a newly developed combined cervical-transoral robotic surgery (C-TORS) approach was investigated and compared with standard TORS. The ability to access and dissect tissues within the various areas of the midline and anterior skull base were evaluated, and techniques to enhance visualization and instrumentation were developed. Results: Standard TORS approaches did not provide adequate access to the midline and anterior skull base; however, the newly developed C-TORS approach was successful in providing the surgical access to these regions of the skull base. Conclusion: Robotic surgery is an exciting minimally invasive approach to the skull base that warrants continued preclinical investigation and development

  16. Rapid tomographic reconstruction based on machine learning for time-resolved combustion diagnostics

    Science.gov (United States)

    Yu, Tao; Cai, Weiwei; Liu, Yingzheng

    2018-04-01

    Optical tomography has attracted surged research efforts recently due to the progress in both the imaging concepts and the sensor and laser technologies. The high spatial and temporal resolutions achievable by these methods provide unprecedented opportunity for diagnosis of complicated turbulent combustion. However, due to the high data throughput and the inefficiency of the prevailing iterative methods, the tomographic reconstructions which are typically conducted off-line are computationally formidable. In this work, we propose an efficient inversion method based on a machine learning algorithm, which can extract useful information from the previous reconstructions and build efficient neural networks to serve as a surrogate model to rapidly predict the reconstructions. Extreme learning machine is cited here as an example for demonstrative purpose simply due to its ease of implementation, fast learning speed, and good generalization performance. Extensive numerical studies were performed, and the results show that the new method can dramatically reduce the computational time compared with the classical iterative methods. This technique is expected to be an alternative to existing methods when sufficient training data are available. Although this work is discussed under the context of tomographic absorption spectroscopy, we expect it to be useful also to other high speed tomographic modalities such as volumetric laser-induced fluorescence and tomographic laser-induced incandescence which have been demonstrated for combustion diagnostics.

  17. Improving treatment of neurodevelopmental disorders: recommendations based on preclinical studies.

    Science.gov (United States)

    Homberg, Judith R; Kyzar, Evan J; Stewart, Adam Michael; Nguyen, Michael; Poudel, Manoj K; Echevarria, David J; Collier, Adam D; Gaikwad, Siddharth; Klimenko, Viktor M; Norton, William; Pittman, Julian; Nakamura, Shun; Koshiba, Mamiko; Yamanouchi, Hideo; Apryatin, Sergey A; Scattoni, Maria Luisa; Diamond, David M; Ullmann, Jeremy F P; Parker, Matthew O; Brown, Richard E; Song, Cai; Kalueff, Allan V

    2016-01-01

    Neurodevelopmental disorders (NDDs) are common and severely debilitating. Their chronic nature and reliance on both genetic and environmental factors makes studying NDDs and their treatment a challenging task. Herein, the authors discuss the neurobiological mechanisms of NDDs, and present recommendations on their translational research and therapy, outlined by the International Stress and Behavior Society. Various drugs currently prescribed to treat NDDs also represent a highly diverse group. Acting on various neurotransmitter and physiological systems, these drugs often lack specificity of action, and are commonly used to treat multiple other psychiatric conditions. There has also been relatively little progress in the development of novel medications to treat NDDs. Based on clinical, preclinical and translational models of NDDs, our recommendations cover a wide range of methodological approaches and conceptual strategies. To improve pharmacotherapy and drug discovery for NDDs, we need a stronger emphasis on targeting multiple endophenotypes, a better dissection of genetic/epigenetic factors or "hidden heritability," and a careful consideration of potential developmental/trophic roles of brain neurotransmitters. The validity of animal NDD models can be improved through discovery of novel (behavioral, physiological and neuroimaging) biomarkers, applying proper environmental enrichment, widening the spectrum of model organisms, targeting developmental trajectories of NDD-related behaviors and comorbid conditions beyond traditional NDDs. While these recommendations cannot be addressed all in once, our increased understanding of NDD pathobiology may trigger innovative cross-disciplinary research expanding beyond traditional methods and concepts.

  18. Advances in tomographic PIV

    NARCIS (Netherlands)

    Novara, M.

    2013-01-01

    This research deals with advanced developments in 3D particle image velocimetry based on the tomographic PIV technique (Tomo-PIV). The latter is a relatively recent measurement technique introduced by Elsinga et al. in 2005, which is based on the tomographic reconstruction of particle tracers in

  19. Tomographic capabilities of the new GEM based SXR diagnostic of WEST

    Science.gov (United States)

    Jardin, A.; Mazon, D.; O'Mullane, M.; Mlynar, J.; Loffelmann, V.; Imrisek, M.; Chernyshova, M.; Czarski, T.; Kasprowicz, G.; Wojenski, A.; Bourdelle, C.; Malard, P.

    2016-07-01

    The tokamak WEST (Tungsten Environment in Steady-State Tokamak) will start operating by the end of 2016 as a test bed for the ITER divertor components in long pulse operation. In this context, radiative cooling of heavy impurities like tungsten (W) in the Soft X-ray (SXR) range [0.1 keV; 20 keV] is a critical issue for the plasma core performances. Thus reliable tools are required to monitor the local impurity density and avoid W accumulation. The WEST SXR diagnostic will be equipped with two new GEM (Gas Electron Multiplier) based poloidal cameras allowing to perform 2D tomographic reconstructions in tunable energy bands. In this paper tomographic capabilities of the Minimum Fisher Information (MFI) algorithm developed for Tore Supra and upgraded for WEST are investigated, in particular through a set of emissivity phantoms and the standard WEST scenario including reconstruction errors, influence of noise as well as computational time.

  20. Application of THz probe radiation in low-coherent tomographs based on spatially separated counterpropagating beams

    Energy Technology Data Exchange (ETDEWEB)

    Kuritsyn, I I; Shkurinov, A P; Nazarov, M M [Department of Physics, M.V. Lomonosov Moscow State University (Russian Federation); Mandrosov, V I [Moscow Institute of Physics and Technology (State University), Dolgoprudnyi, Moscow Region (Russian Federation); Cherkasova, O P [Institute of Laser Physics, Siberian Branch, Russian Academy of Sciences, Novosibirsk (Russian Federation)

    2013-10-31

    A principle of designing a high-resolution low-coherent THz tomograph, which makes it possible to investigate media with a high spatial resolution (in the range λ{sub 0} – 2λ{sub 0}, where λ{sub 0} is the average probe wavelength) is considered. The operation principle of this tomograph implies probing a medium by radiation with a coherence length of 8λ{sub 0} and recording a hologram of a focused image of a fixed layer of this medium using spatially separated counterpropagating object and reference beams. Tomograms of the medium studied are calculated using a temporal approach based on application of the time correlation function of probe radiation. (terahertz radiation)

  1. High-throughput full-automatic synchrotron-based tomographic microscopy

    International Nuclear Information System (INIS)

    Mader, Kevin; Marone, Federica; Hintermueller, Christoph; Mikuljan, Gordan; Isenegger, Andreas; Stampanoni, Marco

    2011-01-01

    At the TOMCAT (TOmographic Microscopy and Coherent rAdiology experimenTs) beamline of the Swiss Light Source with an energy range of 8-45 keV and voxel size from 0.37 (micro)m to 7.4 (micro)m, full tomographic datasets are typically acquired in 5 to 10 min. To exploit the speed of the system and enable high-throughput studies to be performed in a fully automatic manner, a package of automation tools has been developed. The samples are automatically exchanged, aligned, moved to the correct region of interest, and scanned. This task is accomplished through the coordination of Python scripts, a robot-based sample-exchange system, sample positioning motors and a CCD camera. The tools are suited for any samples that can be mounted on a standard SEM stub, and require no specific environmental conditions. Up to 60 samples can be analyzed at a time without user intervention. The throughput of the system is dependent on resolution, energy and sample size, but rates of four samples per hour have been achieved with 0.74 (micro)m voxel size at 17.5 keV. The maximum intervention-free scanning time is theoretically unlimited, and in practice experiments have been running unattended as long as 53 h (the average beam time allocation at TOMCAT is 48 h per user). The system is the first fully automated high-throughput tomography station: mounting samples, finding regions of interest, scanning and reconstructing can be performed without user intervention. The system also includes many features which accelerate and simplify the process of tomographic microscopy.

  2. Promoting evidence based medicine in preclinical medical students via a federated literature search tool.

    Science.gov (United States)

    Keim, Samuel Mark; Howse, David; Bracke, Paul; Mendoza, Kathryn

    2008-01-01

    Medical educators are increasingly faced with directives to teach Evidence Based Medicine (EBM) skills. Because of its nature, integrating fundamental EBM educational content is a challenge in the preclinical years. To analyse preclinical medical student user satisfaction and feedback regarding a clinical EBM search strategy. The authors introduced a custom EBM search option with a self-contained education structure to first-year medical students. The implementation took advantage of a major curricular change towards case-based instruction. Medical student views and experiences were studied regarding the tool's convenience, problems and the degree to which they used it to answer questions raised by case-based instruction. Surveys were completed by 70% of the available first-year students. Student satisfaction and experiences were strongly positive towards the EBM strategy, especially of the tool's convenience and utility for answering issues raised during case-based learning sessions. About 90% of the students responded that the tool was easy to use, productive and accessed for half or more of their search needs. This study provides evidence that the integration of an educational EBM search tool can be positively received by preclinical medical students.

  3. Quantification of wall motion and phase of contraction in tomographic gated blood pool studies using length-based Fourier analysis

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Kenichi; Bunko, Hisashi; Taki, Junichi; Nambu, Ichiro; Shiire, Yasushi; Tonami, Norihisa; Hisada, Kinichi; Tada, Akira; Kojima, Kazuhkio

    1985-03-01

    Length-based Fourier analysis, a new method for quantification of wall motion and timing of contraction, was applied to tomographic gated blood pool study. Two parameters, percent-length shortening (%LS) and length-based phase were calculated based on the time-length curves from a center to ventricular edges, and compared with the count-based method. In mathematical models for tomographic gated blood pool images, the severity of asynergy was easily determined by length-based method, and the accuracy of the parameters was good. As to the setting of the center, fixed center provided more reliable parameters than the method using movable center, i.e., when a center of gravity was determined in each frame. By length-based Fourier analysis, quantification of wall motion was easily performed, and the initial inward movement caused by the accessory conduction pathway was assessed in patients with Wolff-Parkinson-White syndrome. Length-based approach was considered to be reasonable and effective because the movements of the ventricular edges are essential in tomographic gated blood pool images.

  4. Quantification of wall motion and phase of contraction in tomographic gated blood pool studies using length-based Fourier analysis

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Bunko, Hisashi; Taki, Junichi; Nambu, Ichiro; Shiire, Yasushi; Tonami, Norihisa; Hisada, Kinichi; Tada, Akira; Kojima, Kazuhiko.

    1985-01-01

    Length-based Fourier analysis, a new method for quantification of wall motion and timing of contraction, was applied to tomographic gated blood pool study. Two parameters, percent-length shortening (%LS) and length-based phase were calculated based on the time-length curves from a center to ventricular edges, and compared with the count-based method. In mathematical models for tomographic gated blood pool images, the severity of asynergy was easily determined by length-based method, and the accuracy of the parameters was good. As to the setting of the center, fixed center provided more reliable parameters than the method using movable center, i.e., when a center of gravity was determined in each frame. By length-based Fourier analysis, quantification of wall motion was easily performed, and the initial inward movement caused by the accessory conduction pathway was assessed in patients with Wolff-Parkinson-White syndrome. Length-based approach was considered to be reasonable and effective because the movements of the ventricular edges are essential in tomographic gated blood pool images. (author)

  5. Detachments of the subducted Indian continental lithosphere based on 3D finite-frequency tomographic images

    Science.gov (United States)

    Liang, X.; Tian, X.; Wang, M.

    2017-12-01

    Indian plate collided with Eurasian plate at 60 Ma and there are about 3000 km crustal shortening since the continental-continental collision. At least one third of the total amount of crustal shortening between Indian and Eurasian plates could not be accounted by thickened Tibetan crust and surface erosion. It will need a combination of possible transfer of lower crust to the mantle by eclogitization and lateral extrusion. Based on the lithosphere-asthenosphere boundary images beneath the Tibetan plateau, there is also at least the same amount deficit for lithospheric mantle subducted into upper/lower mantle or lateral extrusion with the crust. We have to recover a detailed Indian continental lithosphere image beneath the plateau in order to explain this deficit of mass budget. Combining the new teleseismic body waves recorded by SANDWICH passive seismic array with waveforms from several previous temporary seismic arrays, we carried out finite-frequency tomographic inversions to image three-dimensional velocity structures beneath southern and central Tibetan plateau to examine the possible image of subducted Indian lithosphere in the Tibetan upper mantle. We have recovered a continuous high velocity body in upper mantle and piece-wised high velocity anomalies in the mantle transition zone. Based on their geometry and relative locations, we interpreted these high velocity anomalies as the subducted and detached Indian lithosphere at different episodes of the plateau evolution. Detachments of the subducted Indian lithosphere should have a crucial impact on the volcanism activities and uplift history of the plateau.

  6. Joint global optimization of tomographic data based on particle swarm optimization and decision theory

    Science.gov (United States)

    Paasche, H.; Tronicke, J.

    2012-04-01

    In many near surface geophysical applications multiple tomographic data sets are routinely acquired to explore subsurface structures and parameters. Linking the model generation process of multi-method geophysical data sets can significantly reduce ambiguities in geophysical data analysis and model interpretation. Most geophysical inversion approaches rely on local search optimization methods used to find an optimal model in the vicinity of a user-given starting model. The final solution may critically depend on the initial model. Alternatively, global optimization (GO) methods have been used to invert geophysical data. They explore the solution space in more detail and determine the optimal model independently from the starting model. Additionally, they can be used to find sets of optimal models allowing a further analysis of model parameter uncertainties. Here we employ particle swarm optimization (PSO) to realize the global optimization of tomographic data. PSO is an emergent methods based on swarm intelligence characterized by fast and robust convergence towards optimal solutions. The fundamental principle of PSO is inspired by nature, since the algorithm mimics the behavior of a flock of birds searching food in a search space. In PSO, a number of particles cruise a multi-dimensional solution space striving to find optimal model solutions explaining the acquired data. The particles communicate their positions and success and direct their movement according to the position of the currently most successful particle of the swarm. The success of a particle, i.e. the quality of the currently found model by a particle, must be uniquely quantifiable to identify the swarm leader. When jointly inverting disparate data sets, the optimization solution has to satisfy multiple optimization objectives, at least one for each data set. Unique determination of the most successful particle currently leading the swarm is not possible. Instead, only statements about the Pareto

  7. Estimating multi-phase pore-scale characteristics from X-ray tomographic data using cluster analysis-based segmentation

    DEFF Research Database (Denmark)

    Wildenschild, D.; Culligan, K.A.; Christensen, Britt Stenhøj Baun

    2006-01-01

    present in grey-scale X-ray tomographic images. The approach is based on a cluster analysis technique, used in combination with various other filtering and skeletonization schemes. We apply this segmentation algorithm to analyze multiphase pore-scale flow subjects such as hysteresis and interfacial...... characterization. The results clearly illustrate the advantage of using X-ray tomography together with cluster analysis-based image processing techniques. We were able to obtain detailed information on pore scale distribution of air and water phases, as well as quantitative measures of air bubble size and air...... of individual pores and interfaces. However, separation of the various phases (fluids and solids) in the grey-scale tomographic images has posed a major problem to quantitative analysis of the data. We present an image processing technique that facilitates identification and separation of the various phases...

  8. Deciphering complex, functional structures with synchrotron-based absorption and phase contrast tomographic microscopy

    Science.gov (United States)

    Stampanoni, M.; Reichold, J.; Weber, B.; Haberthür, D.; Schittny, J.; Eller, J.; Büchi, F. N.; Marone, F.

    2010-09-01

    Nowadays, thanks to the high brilliance available at modern, third generation synchrotron facilities and recent developments in detector technology, it is possible to record volumetric information at the micrometer scale within few minutes. High signal-to-noise ratio, quantitative information on very complex structures like the brain micro vessel architecture, lung airways or fuel cells can be obtained thanks to the combination of dedicated sample preparation protocols, in-situ acquisition schemes and cutting-edge imaging analysis instruments. In this work we report on recent experiments carried out at the TOMCAT beamline of the Swiss Light Source [1] where synchrotron-based tomographic microscopy has been successfully used to obtain fundamental information on preliminary models for cerebral fluid flow [2], to provide an accurate mesh for 3D finite-element simulation of the alveolar structure of the pulmonary acinus [3] and to investigate the complex functional mechanism of fuel cells [4]. Further, we introduce preliminary results on the combination of absorption and phase contrast microscopy for the visualization of high-Z nanoparticles in soft tissues, a fundamental information when designing modern drug delivery systems [5]. As an outlook we briefly discuss the new possibilities offered by high sensitivity, high resolution grating interferomtery as well as Zernike Phase contrast nanotomography [6].

  9. Mobile 3D tomograph

    International Nuclear Information System (INIS)

    Illerhaus, Bernhard; Goebbels, Juergen; Onel, Yener; Sauerwein, Christoph

    2008-01-01

    Mobile tomographs often have the problem that high spatial resolution is impossible owing to the position or setup of the tomograph. While the tree tomograph developed by Messrs. Isotopenforschung Dr. Sauerwein GmbH worked well in practice, it is no longer used as the spatial resolution and measuring time are insufficient for many modern applications. The paper shows that the mechanical base of the method is sufficient for 3D CT measurements with modern detectors and X-ray tubes. CT measurements with very good statistics take less than 10 min. This means that mobile systems can be used, e.g. in examinations of non-transportable cultural objects or monuments. Enhancement of the spatial resolution of mobile tomographs capable of measuring in any position is made difficult by the fact that the tomograph has moving parts and will therefore have weight shifts. With the aid of tomographies whose spatial resolution is far higher than the mechanical accuracy, a correction method is presented for direct integration of the Feldkamp algorithm [de

  10. A distribution-based parametrization for improved tomographic imaging of solute plumes

    Science.gov (United States)

    Pidlisecky, Adam; Singha, K.; Day-Lewis, F. D.

    2011-01-01

    Difference geophysical tomography (e.g. radar, resistivity and seismic) is used increasingly for imaging fluid flow and mass transport associated with natural and engineered hydrologic phenomena, including tracer experiments, in situ remediation and aquifer storage and recovery. Tomographic data are collected over time, inverted and differenced against a background image to produce 'snapshots' revealing changes to the system; these snapshots readily provide qualitative information on the location and morphology of plumes of injected tracer, remedial amendment or stored water. In principle, geometric moments (i.e. total mass, centres of mass, spread, etc.) calculated from difference tomograms can provide further quantitative insight into the rates of advection, dispersion and mass transfer; however, recent work has shown that moments calculated from tomograms are commonly biased, as they are strongly affected by the subjective choice of regularization criteria. Conventional approaches to regularization (Tikhonov) and parametrization (image pixels) result in tomograms which are subject to artefacts such as smearing or pixel estimates taking on the sign opposite to that expected for the plume under study. Here, we demonstrate a novel parametrization for imaging plumes associated with hydrologic phenomena. Capitalizing on the mathematical analogy between moment-based descriptors of plumes and the moment-based parameters of probability distributions, we design an inverse problem that (1) is overdetermined and computationally efficient because the image is described by only a few parameters, (2) produces tomograms consistent with expected plume behaviour (e.g. changes of one sign relative to the background image), (3) yields parameter estimates that are readily interpreted for plume morphology and offer direct insight into hydrologic processes and (4) requires comparatively few data to achieve reasonable model estimates. We demonstrate the approach in a series of

  11. Clamshell tomograph

    International Nuclear Information System (INIS)

    Derenzo, S. E.; Budinger, Th. F.

    1984-01-01

    In brief, the invention is a tomograph modified to be in a clamshell configuration so that the ring or rings may be moved to multiple sampling positions. The tomograph includes an array of detectors arranged in successive adjacent relative locations along a closed curve in a first position in a selected plane, and means for securing the detectors in the relative locations in a first sampling position. The securing means is movable in the plane in two sections and pivotable at one point and only one point to enable movement of at least one of the sections to a second sampling position out of the closed curve so that the ends of the section which are opposite the point are moved apart a predetermined space

  12. Tomographic array

    International Nuclear Information System (INIS)

    1976-01-01

    The configuration of a tomographic array in which the object can rotate about its axis is described. The X-ray detector is a cylindrical screen perpendicular to the axis of rotation. The X-ray source has a line-shaped focus coinciding with the axis of rotation. The beam is fan-shaped with one side of this fan lying along the axis of rotation. The detector screen is placed inside an X-ray image multiplier tube

  13. Tomographic array

    International Nuclear Information System (INIS)

    1976-01-01

    A tomographic array with the following characteristics is described. An X-ray screen serving as detector is placed before a photomultiplier tube which itself is placed in front of a television camera connected to a set of image processors. The detector is concave towards the source and is replacable. Different images of the object are obtained simultaneously. Optical fibers and lenses are used for transmission within the system

  14. Computer tomographs

    International Nuclear Information System (INIS)

    Niedzwiedzki, M.

    1982-01-01

    Physical foundations and the developments in the transmission and emission computer tomography are presented. On the basis of the available literature and private communications a comparison is made of the various transmission tomographs. A new technique of computer emission tomography ECT, unknown in Poland, is described. The evaluation of two methods of ECT, namely those of positron and single photon emission tomography is made. (author)

  15. Development of a laser-based heating system for in situ synchrotron-based X-ray tomographic microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Fife, Julie L., E-mail: julie.fife@psi.ch [Laboratory for Synchrotron Radiation, Swiss Light Source, Paul Scherrer Institut, Villigen (Switzerland); Computational Materials Laboratory, Ecole Polytechnique Federale de Lausanne, Lausanne (Switzerland); Rappaz, Michel [Computational Materials Laboratory, Ecole Polytechnique Federale de Lausanne, Lausanne (Switzerland); Pistone, Mattia [Institute for Geochemistry and Petrology, Swiss Federal Institute of Technology of Zurich, Zurich (Switzerland); Celcer, Tine [Laboratory for Synchrotron Radiation, Swiss Light Source, Paul Scherrer Institut, Villigen (Switzerland); The Centre of Excellence for Biosensors, Instrumentation and Process Control, Solkan (Slovenia); Mikuljan, Gordan [Laboratory for Synchrotron Radiation, Swiss Light Source, Paul Scherrer Institut, Villigen (Switzerland); Stampanoni, Marco [Laboratory for Synchrotron Radiation, Swiss Light Source, Paul Scherrer Institut, Villigen (Switzerland); Institute for Biomedical Engineering, Swiss Federal Institute of Technology and University of Zurich, Zurich (Switzerland)

    2012-05-01

    A laser-based heating system has been developed at the TOMCAT beamline of the Swiss Light Source for in situ observations of moderate-to-high-temperature applications of materials. Understanding the formation of materials at elevated temperatures is critical for determining their final properties. Synchrotron-based X-ray tomographic microscopy is an ideal technique for studying such processes because high spatial and temporal resolutions are easily achieved and the technique is non-destructive, meaning additional analyses can take place after data collection. To exploit the state-of-the-art capabilities at the tomographic microscopy and coherent radiology experiments (TOMCAT) beamline of the Swiss Light Source, a general-use moderate-to-high-temperature furnace has been developed. Powered by two diode lasers, it provides controlled localized heating, from 673 to 1973 K, to examine many materials systems and their dynamics in real time. The system can also be operated in various thermal modalities. For example, near-isothermal conditions at a given sample location can be achieved with a prescribed time-dependent temperature. This mode is typically used to study isothermal phase transformations; for example, the formation of equiaxed grains in metallic systems or to nucleate and grow bubble foams in silicate melts under conditions that simulate volcanic processes. In another mode, the power of the laser can be fixed and the specimen moved at a constant speed in a user-defined thermal gradient. This is similar to Bridgman solidification, where the thermal gradient and cooling rate control the microstructure formation. This paper details the experimental set-up and provides multiple proofs-of-concept that illustrate the versatility of using this laser-based heating system to explore, in situ, many elevated-temperature phenomena in a variety of materials.

  16. Plant-based medicines for anxiety disorders, Part 1: a review of preclinical studies.

    Science.gov (United States)

    Sarris, Jerome; McIntyre, Erica; Camfield, David A

    2013-03-01

    Research in the area of herbal psychopharmacology has revealed a variety of promising medicines that may provide benefit in the treatment of general anxiety and specific anxiety disorders. However, a comprehensive review of plant-based anxiolytics has been absent to date. This article (part 1) reviews herbal medicines for which only preclinical investigations for anxiolytic activity have been performed. In part 2, we review herbal medicines for which there have been clinical investigations for anxiolytic activity. An open-ended, language-restricted (English) search of MEDLINE (PubMed), CINAHL, Scopus and the Cochrane Library databases was conducted (up to 28 October 2012) using specific search criteria to identify herbal medicines that have been investigated for anxiolytic activity. This search of the literature revealed 1,525 papers, from which 53 herbal medicines were included in the full review (having at least one study using the whole plant extract). Of these plants, 21 had human clinical trial evidence (reviewed in part 2), with another 32 having solely preclinical studies (reviewed here in part 1). Preclinical evidence of anxiolytic activity (without human clinical trials) was found for Albizia julibrissin, Sonchus oleraceus, Uncaria rhynchophylla, Stachys lavandulifolia, Cecropia glazioui, Magnolia spp., Eschscholzia californica, Erythrina spp., Annona spp., Rubus brasiliensis, Apocynum venetum, Nauclea latifolia, Equisetum arvense, Tilia spp., Securidaca longepedunculata, Achillea millefolium, Leea indica, Juncus effusus, Coriandrum sativum, Eurycoma longifolia, Turnera diffusa, Euphorbia hirta, Justicia spp., Crocus sativus, Aloysia polystachya, Albies pindrow, Casimiroa edulis, Davilla rugosa, Gastrodia elata, Sphaerathus indicus, Zizyphus jujuba and Panax ginseng. Common mechanisms of action for the majority of botanicals reviewed primarily involve GABA, either via direct receptor binding or ionic channel or cell membrane modulation; GABA transaminase

  17. Preclinical animal acute toxicity studies of new developed MRI contrast agent based on gadolinium

    Science.gov (United States)

    Nam, I. F.; Zhuk, V. V.

    2015-04-01

    Acute toxicity test of new developed MRI contrast agent based on disodium salt of gadopentetic acid complex were carried out on Mus musculus and Sprague Dawley rats according to guidelines of preclinical studies [1]. Groups of six animals each were selected for experiment. Death and clinical symptoms of animals were recorded during 14 days. As a result the maximum tolerated dose (MTD) for female mice is 2.8 mM/kg of body weight, male mice - 1.4 mM/kg, female rats - 2.8 mM/kg, male rats - 5.6 mM/kg of body weight. No Observed Adverse Effect Dose (NOAEL) for female mice is 1.4 mM/kg, male mice - 0.7 mM/kg, male and female rats - 0.7 mM/kg. According to experimental data new developed MRI contrast agent based on Gd-DTPA complex is low-toxic.

  18. Linear information retrieval method in X-ray grating-based phase contrast imaging and its interchangeability with tomographic reconstruction

    Science.gov (United States)

    Wu, Z.; Gao, K.; Wang, Z. L.; Shao, Q. G.; Hu, R. F.; Wei, C. X.; Zan, G. B.; Wali, F.; Luo, R. H.; Zhu, P. P.; Tian, Y. C.

    2017-06-01

    In X-ray grating-based phase contrast imaging, information retrieval is necessary for quantitative research, especially for phase tomography. However, numerous and repetitive processes have to be performed for tomographic reconstruction. In this paper, we report a novel information retrieval method, which enables retrieving phase and absorption information by means of a linear combination of two mutually conjugate images. Thanks to the distributive law of the multiplication as well as the commutative law and associative law of the addition, the information retrieval can be performed after tomographic reconstruction, thus simplifying the information retrieval procedure dramatically. The theoretical model of this method is established in both parallel beam geometry for Talbot interferometer and fan beam geometry for Talbot-Lau interferometer. Numerical experiments are also performed to confirm the feasibility and validity of the proposed method. In addition, we discuss its possibility in cone beam geometry and its advantages compared with other methods. Moreover, this method can also be employed in other differential phase contrast imaging methods, such as diffraction enhanced imaging, non-interferometric imaging, and edge illumination.

  19. A tensor-based dictionary learning approach to tomographic image reconstruction

    DEFF Research Database (Denmark)

    Soltani, Sara; Kilmer, Misha E.; Hansen, Per Christian

    2016-01-01

    We consider tomographic reconstruction using priors in the form of a dictionary learned from training images. The reconstruction has two stages: first we construct a tensor dictionary prior from our training data, and then we pose the reconstruction problem in terms of recovering the expansion...... coefficients in that dictionary. Our approach differs from past approaches in that (a) we use a third-order tensor representation for our images and (b) we recast the reconstruction problem using the tensor formulation. The dictionary learning problem is presented as a non-negative tensor factorization problem...... with sparsity constraints. The reconstruction problem is formulated in a convex optimization framework by looking for a solution with a sparse representation in the tensor dictionary. Numerical results show that our tensor formulation leads to very sparse representations of both the training images...

  20. Industrial dynamic tomographic reconstruction

    International Nuclear Information System (INIS)

    Oliveira, Eric Ferreira de

    2016-01-01

    The state of the art methods applied to industrial processes is currently based on the principles of classical tomographic reconstructions developed for tomographic patterns of static distributions, or is limited to cases of low variability of the density distribution function of the tomographed object. Noise and motion artifacts are the main problems caused by a mismatch in the data from views acquired in different instants. All of these add to the known fact that using a limited amount of data can result in the presence of noise, artifacts and some inconsistencies with the distribution under study. One of the objectives of the present work is to discuss the difficulties that arise from implementing reconstruction algorithms in dynamic tomography that were originally developed for static distributions. Another objective is to propose solutions that aim at reducing a temporal type of information loss caused by employing regular acquisition systems to dynamic processes. With respect to dynamic image reconstruction it was conducted a comparison between different static reconstruction methods, like MART and FBP, when used for dynamic scenarios. This comparison was based on a MCNPx simulation as well as an analytical setup of an aluminum cylinder that moves along the section of a riser during the process of acquisition, and also based on cross section images from CFD techniques. As for the adaptation of current tomographic acquisition systems for dynamic processes, this work established a sequence of tomographic views in a just-in-time fashion for visualization purposes, a form of visually disposing density information as soon as it becomes amenable to image reconstruction. A third contribution was to take advantage of the triple color channel necessary to display colored images in most displays, so that, by appropriately scaling the acquired values of each view in the linear system of the reconstruction, it was possible to imprint a temporal trace into the regularly

  1. Benefits of Case-Based versus Traditional Lecture-Based Instruction in a Preclinical Removable Prosthodontics Course.

    Science.gov (United States)

    Samuelson, David B; Divaris, Kimon; De Kok, Ingeborg J

    2017-04-01

    This study compared the acceptability and relative effectiveness of case-based learning (CBL) versus traditional lecture-based (LB) instruction in a preclinical removable prosthodontics course in the University of North Carolina at Chapel Hill School of Dentistry DDS curriculum. The entire second-year class (N=82) comprised this crossover study's sample. Assessments of baseline comprehension and confidence in removable partial denture (RPD) treatment planning were conducted at the beginning of the course. Near the end of the course, half of the class received CBL and LB instruction in an RPD module in alternating sequence, with students serving as their own control group. Assessments of perceived RPD treatment planning efficacy, comprehension, and instruction method preference were administered directly after students completed the RPD module and six months later. Analyses of variance accounting for period, carryover, and sequence effects were used to determine the relative effects of each approach using a peffects, CBL was also associated with higher gains in RPD treatment planning comprehension (p=0.04) and perceived efficacy (p=0.01) compared to LB instruction. These gains diminished six months after the course-a finding based on a 49% follow-up response rate. Overall, the students overwhelmingly preferred CBL to LB instruction, and the findings suggest small albeit measurable educational benefits associated with CBL. This study's findings support the introduction and further testing of CBL in the preclinical dental curriculum, in anticipation of possible future benefits evident during clinical training.

  2. Neural network based tomographic approach to detect earthquake-related ionospheric anomalies

    Directory of Open Access Journals (Sweden)

    S. Hirooka

    2011-08-01

    Full Text Available A tomographic approach is used to investigate the fine structure of electron density in the ionosphere. In the present paper, the Residual Minimization Training Neural Network (RMTNN method is selected as the ionospheric tomography with which to investigate the detailed structure that may be associated with earthquakes. The 2007 Southern Sumatra earthquake (M = 8.5 was selected because significant decreases in the Total Electron Content (TEC have been confirmed by GPS and global ionosphere map (GIM analyses. The results of the RMTNN approach are consistent with those of TEC approaches. With respect to the analyzed earthquake, we observed significant decreases at heights of 250–400 km, especially at 330 km. However, the height that yields the maximum electron density does not change. In the obtained structures, the regions of decrease are located on the southwest and southeast sides of the Integrated Electron Content (IEC (altitudes in the range of 400–550 km and on the southern side of the IEC (altitudes in the range of 250–400 km. The global tendency is that the decreased region expands to the east with increasing altitude and concentrates in the Southern hemisphere over the epicenter. These results indicate that the RMTNN method is applicable to the estimation of ionospheric electron density.

  3. First experience with a mobile computed tomograph in the USSR

    International Nuclear Information System (INIS)

    Portnoj, L.M.

    1989-01-01

    Utilization experience of mobile computerized tomograph mounted in the bus is presented. Problems concerning staff, selection of medical base institutes etc are considered. Efficiency of mobile computerized tomographes in revealing different diseases is pointed out

  4. Problem-based learning in pre-clinical medical education: 22 years of outcome research.

    Science.gov (United States)

    Hartling, Lisa; Spooner, Carol; Tjosvold, Lisa; Oswald, Anna

    2010-01-01

    To conduct a systematic review of problem-based learning (PBL) in undergraduate, pre-clinical medical education. A research librarian developed comprehensive search strategies for MEDLINE, PSYCINFO, and ERIC (1985-2007). Two reviewers independently screened search results and applied inclusion criteria. Studies were included if they had a comparison group and reported primary data for evaluative outcomes. One reviewer extracted data and a second reviewer checked data for accuracy. Two reviewers independently assessed methodological quality. Quantitative synthesis was not performed due to heterogeneity. A qualitative review with detailed evidence tables is provided. Thirty unique studies were included. Knowledge acquisition measured by exam scores was the most frequent outcome reported; 12 of 15 studies found no significant differences. Individual studies demonstrated either improved clerkship (N = 3) or residency (N = 1) performance, or benefits on some clinical competencies during internships for PBL (N = 1). Three of four studies found some benefits for PBL when evaluating diagnostic accuracy. Three studies found few differences of clinical (or practical) importance on the impact of PBL on practicing physicians. Twenty-two years of research shows that PBL does not impact knowledge acquisition; evidence for other outcomes does not provide unequivocal support for enhanced learning. Work is needed to determine the most appropriate outcome measures to capture and quantify the effects of PBL. General conclusions are limited by methodological weaknesses and heterogeneity across studies. The critical appraisal of previous studies, conducted as part of this review, provides direction for future research in this area.

  5. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    Abele, M.

    1983-01-01

    A computerized tomographic scanning apparatus suitable for diagnosis and for improving target identification in stereotactic neurosurgery is described. It consists of a base, a source of penetrating energy, a detector which produces scanning signals and detector positioning means. A frame with top and bottom arms secures the detector and source to the top and bottom arms respectively. A drive mechanism rotates the frame about an axis along which the frame may also be moved. Finally, the detector may be moved relative to the bottom arm in a direction contrary to the rotation of the frame. (U.K.)

  6. In question: the scientific value of preclinical safety pharmacology and toxicology studies with cell-based therapies

    Directory of Open Access Journals (Sweden)

    Christiane Broichhausen

    2014-01-01

    Full Text Available A new cell-based medicinal product containing human regulatory macrophages, known as Mreg_UKR, has been developed and conforms to expectations of a therapeutic drug. Here, Mreg_UKR was subjected to pharmacokinetic, safety pharmacology, and toxicological testing, which identified no adverse reactions. These results would normally be interpreted as evidence of the probable clinical safety of Mreg_UKR; however, we contend that, owing to their uncertain biological relevance, our data do not fully support this conclusion. This leads us to question whether there is adequate scientific justification for preclinical safety testing of similar novel cell-based medicinal products using animal models. In earlier work, two patients were treated with regulatory macrophages prior to kidney transplantation. In our opinion, the absence of acute or chronic adverse effects in these cases is the most convincing available evidence of the likely safety of Mreg_UKR in future recipients. On this basis, we consider that safety information from previous clinical investigations of related cell products should carry greater weight than preclinical data when evaluating the safety profile of novel cell-based medicinal products. By extension, we argue that omitting extensive preclinical safety studies before conducting small-scale exploratory clinical investigations of novel cell-based medicinal products data may be justifiable in some instances.

  7. A mega Ultra Low Velocity Zone at the Base of the Iceland Plume: a Target for Tomographic Telescope Implementation

    Science.gov (United States)

    Romanowicz, Barbara; Yuan, Kaiqing; Masson, Yder; Adourian, Sevan

    2017-04-01

    We have recently constructed the first global whole mantle radially anisotropic shear wave velocity model based on time domain full waveform inversion and numerical wavefield computations using the Spectral Element Method (French et al., 2013; French and Romanowicz, 2014). This model's most salient features are broad chimney-like low velocity conduits, rooted within the large-low-shear-velocity provinces (LLSVPs) at the base of the mantle, and extending from the core-mantle boundary up through most of the lower mantle, projecting to the earth's surface in the vicinity of major hotspots. The robustness of these features is confirmed through several non-linear synthetic tests, which we present here, including several iterations of inversion using a different starting model than that which served for the published model. The roots of these not-so-classical "plumes" are regions of more pronounced low shear velocity. While the detailed structure is not yet resolvable tomographically, at least two of them contain large (>800 km diameter) ultra-low-velocity zones (ULVZs), one under Hawaii (Cottaar and Romanowicz, 2012) and the other one under Samoa (Thorne et al., 2013). Through 3D numerical forward modelling of Sdiff phases down to 10s period, using data from broadband arrays illuminating the base of the Iceland plume from different directions, we show that such a large ULVZ also exists at the root of this plume, embedded within a taller region of moderately reduced low shear velocity, such as proposed by He et al. (2015). We also show that such a wide, but localized ULVZ is unique in a broad region around the base of the Iceland Plume. Because of the intense computational effort required for forward modelling of trial structures, to first order this ULVZ is represented by a cylindrical structure of diameter 900 km, height 20 km and velocity reduction 20%. To further refine the model, we have developed a technique which we call "tomographic telescope", in which we are

  8. SU-E-T-606: Performance of MR-Based 3D FXG Dosimetry for Preclinical Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Welch, M [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Jaffray, D [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, ON (Canada); Department of Radiation Oncology, University of Toronto, Toronto, ON (Canada); TECHNA Institute for the Advancement of Technology for Health, Toronto, ON (Canada)

    2015-06-15

    Purpose: Technological advances have revolutionized preclinical radiation research to enable precise radiation delivery in preclinical models. Kilovoltage x-rays and complex geometries in preclinical radiation studies challenge conventional dosimetry methods. Previously developed gel-based dosimetry provides a viable means of accommodating complex geometries and accurately reporting dose at kV energies. This paper will describe the development and evaluation of gel-based ferrous xylenol-orange (FXG) dosimetry using a 7T preclinical imaging system. Methods: To confirm water equivalence, Zeff values were calculated for the FXG material, water and ICRU defined soft tissue. Proton T1 relaxivity response in FXG was measured using a preclinical 7T MR and a small animal irradiator for a dose range of 1–22 Gy. FXG was contained in 50 ml centrifuge tubes and irradiated with a 225 kVp x-ray beam at a nominal dose rate of 2.3 Gy/min. Pre and post irradiation maps of the T1 relaxivity were collected using variable TR spin-echo imaging (TE 6.65 ms; TR 500, 750, 1000, 1500, 2000, 3000 and 5000 ms) with 2 mm thick slices, 0.325 mm/pixel, 3 averages and an acquisition time of 26 minutes. A linear fit to the change in relaxation rate (1/T1) for the delivered doses reported the gel sensitivity in units of ms{sup -1}Gy{sup -1}. Irradiation and imaging studies were repeated using three batches of gel over 72 hrs. Results: FXG has a Zeff of 3.8 for the 225 kVp spectrum used; differing from water and ICRU defined soft tissue by 0.5% and 2.5%, respectively. The average sensitivity for the FXG dosimeter was 31.5 ± 0.7 ms{sup -1}Gy{sup -1} (R{sup 2} = 0.9957) with a y-intercept of −29.4 ± 9.0 ms{sup -1}. Conclusion: Preliminary results for the FXG dosimeter properties, sensitivity, and dose linearity at preclinical energies is promising. Future work will explore anatomically relevant tissue inclusions to test MR performance. Student funding provided by The Terry Fox Foundation

  9. A computerized pre-clinical test for cemented hip prostheses based on finite element techniques

    NARCIS (Netherlands)

    Stolk, Jan

    2003-01-01

    Despite the success of cemented total hip replacement (THR), high failure rates are occasionally reported for cemented hip implants that are introduced on the orthopaedic market. Rigorous pre-clinical testing of hip implants could prevent these disasters, by detecting unsafe implant designs at a

  10. Preclinical detection of porcine circovirus type 2 infection using an ultrasensitive nanoparticle DNA probe-based PCR assay.

    Directory of Open Access Journals (Sweden)

    Yong Huang

    Full Text Available Porcine circovirus type 2 (PCV2 has emerged as one of the most important pathogens affecting swine production globally. Preclinical identification of PCV2 is very important for effective prophylaxis of PCV2-associated diseases. In this study, we developed an ultrasensitive nanoparticle DNA probe-based PCR assay (UNDP-PCR for PCV2 detection. Magnetic microparticles coated with PCV2 specific DNA probes were used to enrich PCV2 DNA from samples, then gold nanoparticles coated with PCV2 specific oligonucleotides were added to form a sandwich nucleic acid-complex. After the complex was formed, the oligonucleotides were released and characterized by PCR. This assay exhibited about 500-fold more sensitive than conventional PCR, with a detection limit of 2 copies of purified PCV2 genomic DNA and 10 viral copies of PCV2 in serum. The assay has a wide detection range for all of PCV2 genotypes with reliable reproducibility. No cross-reactivity was observed from the samples of other related viruses including porcine circovirus type 1, porcine parvovirus, porcine pseudorabies virus, porcine reproductive and respiratory syndrome virus and classical swine fever virus. The positive detection rate of PCV2 specific UNDP-PCR in 40 preclinical field samples was 27.5%, which appeared greater than that by conventional and real-time PCR and appeared application potency in evaluation of the viral loads levels of preclinical infection samples. The UNDP-PCR assay reported here can reliably rule out false negative results from antibody-based assays, provide a nucleic acid extraction free, specific, ultrasensitive, economic and rapid diagnosis method for preclinical PCV2 infection in field, which may help prevent large-scale outbreaks.

  11. Tomographical properties of uniformly redundant arrays

    International Nuclear Information System (INIS)

    Cannon, T.M.; Fenimore, E.E.

    1978-01-01

    Recent work in coded aperture imaging has shown that the uniformly redundant array (URA) can image distant planar radioactive sources with no artifacts. The performance of two URA apertures when used in a close-up tomographic imaging system is investigated. It is shown that a URA based on m sequences is superior to one based on quadratic residues. The m sequence array not only produces less obnoxious artifacts in tomographic imaging, but is also more resilient to some described detrimental effects of close-up imaging. It is shown that in spite of these close-up effects, tomographic depth resolution increases as the source is moved closer to the detector

  12. Genetic modification of risk assessment based on staging of preclinical type 1 diabetes in siblings of affected children.

    Science.gov (United States)

    Mrena, S; Savola, K; Kulmala, P; Reijonen, H; Ilonen, J; Akerblom, H K; Knip, M

    2003-06-01

    We set out to study the association between human leukocyte antigen-defined genetic disease susceptibility and the stage of preclinical type 1 diabetes and whether genetic predisposition affects the natural course of preclinical diabetes in initially nondiabetic siblings of affected children. A total of 701 initially unaffected siblings were graded into four stages of preclinical type 1 diabetes based on the initial number of disease-associated autoantibodies detectable close to the time of diagnosis of the index case: no prediabetes (no antibodies), early (one antibody specificity), advanced (two antibodies), and late prediabetes (three or more antibodies). Another classification system covering 659 siblings was based on a combination of the initial number of antibodies and the first-phase insulin response (FPIR) to iv glucose: no prediabetes (no antibodies), early (one antibody specificity, normal FPIR), advanced (two or more antibodies, normal FPIR), and late prediabetes (at least one antibody, reduced FPIR). Genetic susceptibility to type 1 diabetes was defined by human leukocyte antigen identity and DR and DQ genotypes. There was a higher proportion of siblings with late prediabetes initially among those with strong genetic disease susceptibility than among those with decreased genetic predisposition (16.7% vs. 0.5%; P siblings with no signs of prediabetes among those with genotypes conferring decreased risk (91.2% vs. 70.4% among those with high-risk DQB1 genotypes; P siblings than when combined with genetic susceptibility. Genetic susceptibility played a role in whether the initial prediabetic stage progressed (progression in 29.6% of the high-risk siblings compared with 6.6% of the siblings with DQB1 genotypes conferring decreased risk; P siblings of affected children.

  13. Evaluation of tomographic-image based geometries with PENELOPE Monte Carlo

    International Nuclear Information System (INIS)

    Kakoi, A.A.Y.; Galina, A.C.; Nicolucci, P.

    2009-01-01

    The Monte Carlo method can be used to evaluate treatment planning systems or for the determination of dose distributions in radiotherapy planning due to its accuracy and precision. In Monte Carlo simulation packages typically used in radiotherapy, however, a realistic representation of the geometry of the patient can not be used, which compromises the accuracy of the results. In this work, an algorithm for the description of geometries based on CT images of patients, developed to be used with Monte Carlo simulation package PENELOPE, is tested by simulating the dose distribution produced by a photon beam of 10 MV. The geometry simulated was based on CT images of a planning of prostate cancer. The volumes of interest in the treatment were adequately represented in the simulation geometry, allowing the algorithm to be used in verification of doses in radiotherapy treatments. (author)

  14. Physics-based coastal current tomographic tracking using a Kalman filter.

    Science.gov (United States)

    Wang, Tongchen; Zhang, Ying; Yang, T C; Chen, Huifang; Xu, Wen

    2018-05-01

    Ocean acoustic tomography can be used based on measurements of two-way travel-time differences between the nodes deployed on the perimeter of the surveying area to invert/map the ocean current inside the area. Data at different times can be related using a Kalman filter, and given an ocean circulation model, one can in principle now cast and even forecast current distribution given an initial distribution and/or the travel-time difference data on the boundary. However, an ocean circulation model requires many inputs (many of them often not available) and is unpractical for estimation of the current field. A simplified form of the discretized Navier-Stokes equation is used to show that the future velocity state is just a weighted spatial average of the current state. These weights could be obtained from an ocean circulation model, but here in a data driven approach, auto-regressive methods are used to obtain the time and space dependent weights from the data. It is shown, based on simulated data, that the current field tracked using a Kalman filter (with an arbitrary initial condition) is more accurate than that estimated by the standard methods where data at different times are treated independently. Real data are also examined.

  15. Conceptual design and development of GEM based detecting system for tomographic tungsten focused transport monitoring

    Science.gov (United States)

    Chernyshova, M.; Czarski, T.; Malinowski, K.; Kowalska-Strzęciwilk, E.; Poźniak, K.; Kasprowicz, G.; Zabołotny, W.; Wojeński, A.; Kolasiński, P.; Mazon, D.; Malard, P.

    2015-10-01

    Implementing tungsten as a plasma facing material in ITER and future fusion reactors will require effective monitoring of not just its level in the plasma but also its distribution. That can be successfully achieved using detectors based on Gas Electron Multiplier (GEM) technology. This work presents the conceptual design of the detecting unit for poloidal tomography to be tested at the WEST project tokamak. The current stage of the development is discussed covering aspects which include detector's spatial dimensions, gas mixtures, window materials and arrangements inside and outside the tokamak ports, details of detector's structure itself and details of the detecting module electronics. It is expected that the detecting unit under development, when implemented, will add to the safe operation of tokamak bringing the creation of sustainable nuclear fusion reactors a step closer. A shorter version of this contribution is due to be published in PoS at: 1st EPS conference on Plasma Diagnostics

  16. A study on laser-based ultrasonic technique by the use of guided wave tomographic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Park, Junpil, E-mail: jpp@pusan.ac.kr; Lim, Juyoung, E-mail: jpp@pusan.ac.kr [Graduate school, School of Mechanical Engineering, Pusan National University (Korea, Republic of); Cho, Younho [School of Mechanical Engineering, Pusan National University (Korea, Republic of); Krishnaswamy, Sridhar [Center for Quality Engineering and Failure Prevention, Northwestern University, Evanston, IL (United States)

    2015-03-31

    Guided wave tests are impractical for investigating specimens with limited accessibility and coarse surfaces or geometrically complicated features. A non-contact setup with a laser ultrasonic transmitter and receiver is the classic attractive for guided wave inspection. The present work was done to develop a non-contact guided-wave tomography technique by laser ultrasonic technique in a plate-like structure. A method for Lam wave generation and detection in an aluminum plate with a pulse laser ultrasonic transmitter and a Michelson interferometer receiver has been developed. In the images obtained by laser scanning, the defect shape and area showed good agreement with the actual defect. The proposed approach can be used as a non-contact-based online inspection and monitoring technique.

  17. MicroCT-Based Skeletal Models for Use in Tomographic Voxel Phantoms for Radiological Protection

    International Nuclear Information System (INIS)

    Bolch, Wesley

    2010-01-01

    The University of Florida (UF) proposes to develop two high-resolution image-based skeletal dosimetry models for direct use by ICRP Committee 2's Task Group on Dose Calculation in their forthcoming Reference Voxel Male (RVM) and Reference Voxel Female (RVF) whole-body dosimetry phantoms. These two phantoms are CT-based, and thus do not have the image resolution to delineate and perform radiation transport modeling of the individual marrow cavities and bone trabeculae throughout their skeletal structures. Furthermore, new and innovative 3D microimaging techniques will now be required for the skeletal tissues following Committee 2's revision of the target tissues of relevance for radiogenic bone cancer induction. This target tissue had been defined in ICRP Publication 30 as a 10-(micro)m cell layer on all bone surfaces of trabecular and cortical bone. The revised target tissue is now a 50-(micro)m layer within the marrow cavities of trabecular bone only and is exclusive of the marrow adipocytes. Clearly, this new definition requires the use of 3D microimages of the trabecular architecture not available from past 2D optical studies of the adult skeleton. With our recent acquisition of two relatively young cadavers (males of age 18-years and 40-years), we will develop a series of reference skeletal models that can be directly applied to (1) the new ICRP reference voxel man and female phantoms developed for the ICRP, and (2) pediatric phantoms developed to target the ICRP reference children. Dosimetry data to be developed will include absorbed fractions for internal beta and alpha-particle sources, as well as photon and neutron fluence-to-dose response functions for direct use in external dosimetry studies of the ICRP reference workers and members of the general public

  18. MicroCT-Based Skeletal Models for Use in Tomographic Voxel Phantoms for Radiological Protection

    Energy Technology Data Exchange (ETDEWEB)

    Bolch, Wesley [Univ. of Florida, Gainesville, FL (United States)

    2010-03-30

    The University of Florida (UF) proposes to develop two high-resolution image-based skeletal dosimetry models for direct use by ICRP Committee 2’s Task Group on Dose Calculation in their forthcoming Reference Voxel Male (RVM) and Reference Voxel Female (RVF) whole-body dosimetry phantoms. These two phantoms are CT-based, and thus do not have the image resolution to delineate and perform radiation transport modeling of the individual marrow cavities and bone trabeculae throughout their skeletal structures. Furthermore, new and innovative 3D microimaging techniques will now be required for the skeletal tissues following Committee 2’s revision of the target tissues of relevance for radiogenic bone cancer induction. This target tissue had been defined in ICRP Publication 30 as a 10-μm cell layer on all bone surfaces of trabecular and cortical bone. The revised target tissue is now a 50-μm layer within the marrow cavities of trabecular bone only and is exclusive of the marrow adipocytes. Clearly, this new definition requires the use of 3D microimages of the trabecular architecture not available from past 2D optical studies of the adult skeleton. With our recent acquisition of two relatively young cadavers (males of age 18-years and 40-years), we will develop a series of reference skeletal models that can be directly applied to (1) the new ICRP reference voxel man and female phantoms developed for the ICRP, and (2) pediatric phantoms developed to target the ICRP reference children. Dosimetry data to be developed will include absorbed fractions for internal beta and alpha-particle sources, as well as photon and neutron fluence-to-dose response functions for direct use in external dosimetry studies of the ICRP reference workers and members of the general public

  19. Problem-based learning versus a traditional educational methodology: a comparison of preclinical and clinical periodontics performance.

    Science.gov (United States)

    Rich, Sandra K; Keim, Robert G; Shuler, Charles F

    2005-06-01

    To evaluate efficacy of a problem-based learning (PBL) pedagogy in preclinical and clinical teaching, test scores of 234 undergraduate dental students from the conventionally taught classes of 2003 and 2004 were compared with scores of 274 dental students from the PBL classes of 2005 and 2006. Although the groups' means were close together, t-test analysis of scores revealed that PBL students performed significantly better than traditional (TRAD) students on midterm (p=.0001) and final (p=.015) examinations taken on student partner/mock patients. ANOVA comparing the classes with each other showed significant differences for the midterm and final, but not for the clinical examination. Further multiple comparison tests (Tukey HSD) for the midterm and final revealed that differences specifically reflected superior performance of PBL classes against one of the TRAD classes (2004). There was no difference in performance between PBL (n=134) and TRAD (n=233) students on examinations taken with actual clinical patients who were undergoing nonsurgical periodontal treatment. Over a two-year period, PBL students rated their program instructors at a mean of 4.41 on a Likert-type scale of 1 (not helpful) to 5 (outstanding). The program provides a PBL model for teaching preclinical and clinical skills supported by a four-year evaluation of manual skills outcomes.

  20. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to a multiplexer slip ring means for receiving output from the detectors and enabling interfeed to the image reconstruction station. (U.K.)

  1. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are presented of a tomographic scanning apparatus, its rotational assembly, and the control and circuit elements, with particular reference to the amplifier and multiplexing circuits enabling detector signal calibration. (U.K.)

  2. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification relates to a tomographic scanning apparatus using a fan beam and digital output signal, and particularly to the design of the gas-pressurized ionization detection system. (U.K.)

  3. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification describes a tomographic scanning apparatus, with particular reference to the adjustable fan beam and its collimator system, together with the facility for taking a conventional x-radiograph without moving the patient. (U.K.)

  4. Video-based Learning Versus Traditional Method for Preclinical Course of Complete Denture Fabrication.

    Science.gov (United States)

    Fayaz, Amir; Mazahery, Azita; Hosseinzadeh, Mohammad; Yazdanpanah, Samane

    2015-03-01

    Advances in computer science and technology allow the instructors to use instructional multimedia programs to enhance the process of learning for dental students. The purpose of this study was to determine the effect of a new educational modality by using videotapes on the performance of dental students in preclinical course of complete denture fabrication. This quasi-experimental study was performed on 54 junior dental students in Shahid Beheshti University of Medical Sciences (SBMU). Twenty-five and 29 students were evaluated in two consecutive semesters as controls and cases, respectively for the same course. The two groups were matched in terms of "knowledge about complete denture fabrication" and "basic dental skills" using a written test and a practical exam, respectively. After the intervention, performance and clinical skills of students were assessed in 8 steps. Eventually, a post-test was carried out to find changes in knowledge and skills of students in this regard. In the two groups with the same baseline level of knowledge and skills, independent T-test showed that students in the test group had a significantly superior performance in primary impression taking (p= 0.001) and primary cast fabrication (p= 0.001). In terms of anterior teeth set up, students in the control group had a significantly better performance (p= 0.001). Instructional videotapes can aid in teaching fabrication of complete denture and are as effective as the traditional teaching system.

  5. Two-Dimensional High Definition Versus Three-Dimensional Endoscopy in Endonasal Skull Base Surgery: A Comparative Preclinical Study.

    Science.gov (United States)

    Rampinelli, Vittorio; Doglietto, Francesco; Mattavelli, Davide; Qiu, Jimmy; Raffetti, Elena; Schreiber, Alberto; Villaret, Andrea Bolzoni; Kucharczyk, Walter; Donato, Francesco; Fontanella, Marco Maria; Nicolai, Piero

    2017-09-01

    Three-dimensional (3D) endoscopy has been recently introduced in endonasal skull base surgery. Only a relatively limited number of studies have compared it to 2-dimensional, high definition technology. The objective was to compare, in a preclinical setting for endonasal endoscopic surgery, the surgical maneuverability of 2-dimensional, high definition and 3D endoscopy. A group of 68 volunteers, novice and experienced surgeons, were asked to perform 2 tasks, namely simulating grasping and dissection surgical maneuvers, in a model of the nasal cavities. Time to complete the tasks was recorded. A questionnaire to investigate subjective feelings during tasks was filled by each participant. In 25 subjects, the surgeons' movements were continuously tracked by a magnetic-based neuronavigator coupled with dedicated software (ApproachViewer, part of GTx-UHN) and the recorded trajectories were analyzed by comparing jitter, sum of square differences, and funnel index. Total execution time was significantly lower with 3D technology (P < 0.05) in beginners and experts. Questionnaires showed that beginners preferred 3D endoscopy more frequently than experts. A minority (14%) of beginners experienced discomfort with 3D endoscopy. Analysis of jitter showed a trend toward increased effectiveness of surgical maneuvers with 3D endoscopy. Sum of square differences and funnel index analyses documented better values with 3D endoscopy in experts. In a preclinical setting for endonasal skull base surgery, 3D technology appears to confer an advantage in terms of time of execution and precision of surgical maneuvers. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. [Classification of results of studying blood plasma with laser correlation spectroscopy based on semiotics of preclinical and clinical states].

    Science.gov (United States)

    Ternovoĭ, K S; Kryzhanovskiĭ, G N; Musiĭchuk, Iu I; Noskin, L A; Klopov, N V; Noskin, V A; Starodub, N F

    1998-01-01

    The usage of laser correlation spectroscopy for verification of preclinical and clinical states is substantiated. Developed "semiotic" classifier for solving the problems of preclinical and clinical states is presented. The substantiation of biological algorithms as well as the mathematical support and software for the proposed classifier for the data of laser correlation spectroscopy of blood plasma are presented.

  7. Pre-clinical evaluation of an inverse planning module for segmental MLC based IMRT delivery

    International Nuclear Information System (INIS)

    Georg, Dietmar; Kroupa, Bernhard

    2002-01-01

    Phantom tests are performed for pre-clinical evaluation of a commercial inverse planning system (HELAX TMS, V 6.0) for segmented multileaf collimator (MLC) intensity modulated radiotherapy (IMRT) delivery. The optimization module has available two optimization algorithms: the target primary feasibility and the weighted feasibility algorithm, only the latter allows the user to specify weights for structures. In the first series, single beam tests are performed to evaluate the outcome of inverse planning in terms of plausibility for the following situations: oblique incidence, presence of inhomogeneities, multiple targets at different depths and multiple targets with different desired doses. Additionally, for these tests a manual plan is made for comparison. In the absence of organs at risk, both the optimization algorithms are found to assign the highest priority to low dose constraints for targets. In the second series, tests resembling clinical relevant configurations (simultaneous boost and concave target with critical organ) are performed with multiple beam arrangements in order to determine the impact of the system's configuration on inverse planning. It is found that the definition of certain segment number and segment size limitations does not largely compromise treatment plans when using multiple beams. On the other hand, these limitations are important for delivery efficiency and dosimetry. For the number of iterations and voxels per volume of interest, standard values in the system's configuration are considered to be sufficient. Additionally, it is demonstrated that precautions must be taken to precisely define treatment goals when using computerized treatment optimization. Similar phantom tests could be used for a direct dosimetric verification of all steps from inverse treatment planning to IMRT delivery. (note)

  8. Pre-clinical evaluation of a novel nanoemulsion-based hepatitis B mucosal vaccine.

    Directory of Open Access Journals (Sweden)

    Paul E Makidon

    2008-08-01

    Full Text Available Hepatitis B virus infection remains an important global health concern despite the availability of safe and effective prophylactic vaccines. Limitations to these vaccines include requirement for refrigeration and three immunizations thereby restricting use in the developing world. A new nasal hepatitis B vaccine composed of recombinant hepatitis B surface antigen (HBsAg in a novel nanoemulsion (NE adjuvant (HBsAg-NE could be effective with fewer administrations.Physical characterization indicated that HBsAg-NE consists of uniform lipid droplets (349+/-17 nm associated with HBsAg through electrostatic and hydrophobic interactions. Immunogenicity of HBsAg-NE vaccine was evaluated in mice, rats and guinea pigs. Animals immunized intranasally developed robust and sustained systemic IgG, mucosal IgA and strong antigen-specific cellular immune responses. Serum IgG reached > or = 10(6 titers and was comparable to intramuscular vaccination with alum-adjuvanted vaccine (HBsAg-Alu. Normalization showed that HBsAg-NE vaccination correlates with a protective immunity equivalent or greater than 1000 IU/ml. Th1 polarized immune response was indicated by IFN-gamma and TNF-alpha cytokine production and elevated levels of IgG(2 subclass of HBsAg-specific antibodies. The vaccine retains full immunogenicity for a year at 4 degrees C, 6 months at 25 degrees C and 6 weeks at 40 degrees C. Comprehensive pre-clinical toxicology evaluation demonstrated that HBsAg-NE vaccine is safe and well tolerated in multiple animal models.Our results suggest that needle-free nasal immunization with HBsAg-NE could be a safe and effective hepatitis B vaccine, or provide an alternative booster administration for the parenteral hepatitis B vaccines. This vaccine induces a Th1 associated cellular immunity and also may provide therapeutic benefit to patients with chronic hepatitis B infection who lack cellular immune responses to adequately control viral replication. Long-term stability

  9. ICT-Supported, Scenario-Based Learning in Preclinical Veterinary Science Education: Quantifying Learning Outcomes and Facilitating the Novice-Expert Transition

    Science.gov (United States)

    Seddon, Jennifer M.; McDonald, Brenda; Schmidt, Adele L.

    2012-01-01

    Problem and/or scenario-based learning is often deployed in preclinical education and training as a means of: (a) developing students' capacity to respond to authentic, real-world problems; (b) facilitating integration of knowledge across subject areas, and; (c) increasing motivation for learning. Six information and communication technology (ICT)…

  10. Emerging tomographic methods within the petroleum industry

    International Nuclear Information System (INIS)

    Johansen, Geir Anton

    2013-01-01

    Since industrial process tomography was introduced as a concept almost two decades ago, the considerable progress within a large variety of sensing modalities has to a large extent been technology driven. Industrial tomography applications may be divided into three categories: 1) Laboratory systems, 2) Field equipment for diagnostics and mapping purposes, and 3) Permanently installed systems. Examples on emerging methods on all categories will be presented, either from R and D at the University of Bergen and/or our industrial partners. Most developments are within the first category, where tomographs are used to provide better understanding of various processes such as pipe flow, separators, mixers and reactors. Here tomographic data is most often used to provide better process knowledge, for reference measurements and validation and development of process models, and finally for development for instruments and process equipment. The requirement here may be either high spatial resolution or high temporal resolution, or combinations of these. Tomographic field measurements are applied to either to inspect processes or equipment on a regular base or at faulty or irregular operation, or to map multicomponent systems such petroleum reservoirs, their structure and the distribution gas, oil and water within them. The latter will only be briefly touched upon here. Tomographic methods are increasingly being used for process and equipment diagnostics. The requirements vary and solutions based on repetition of single measurements, such as in column scanning, to full tomographic systems where there is sufficiently space or access. The third category is tomographic instruments that are permanently installed in situ in a process. These need not provide full tomographic images and instruments with fewer views are often preferred to reduce complexity and increase the instrument reliability. (author)

  11. Class-Wide Access to a Commercial Step 1 Question Bank During Preclinical Organ-Based Modules: A Pilot Project.

    Science.gov (United States)

    Baños, James H; Pepin, Mark E; Van Wagoner, Nicholas

    2018-03-01

    The authors examined the usefulness of a commercially available Step 1 question bank as a formative academic support tool throughout organ-based modules in an integrated preclinical medical curriculum. The authors also determined the extent to which correlation between question bank utilization and academic metrics varied with Medical College Admission Test (MCAT) scores. In 2015, a cohort of 185 first-year medical students at University of Alabama School of Medicine were provided with 18-month full access to a commercially available Step 1 question bank of over 2,100 items throughout organ-based modules, although there were no requirements for use. Data on student use of the question bank were collected via an online administrative portal. Relationships between question bank utilization and academic outcomes including exams, module grades, and United States Medical Licensing Examination (USMLE) Step 1 were determined using multiple linear regression. MCAT scores and number of items attempted in the question bank significantly predicted all academic measures, with question bank utilization as the stronger predictor. The association between question bank utilization and academic outcome was stronger for individuals with lower MCAT scores. The findings elucidate a novel academic support mechanism that, for some programs, may help bridge the gap between holistic and mission-based admissions practices and a residency match process that places a premium on USMLE exam scores. Distributed formative use of USMLE Step 1 practice questions may be of value as an academic support tool that benefits all students, but particularly those entering with lower MCAT scores.

  12. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to the means of adjusting the apparent gain of the signal processing means for receiving output signals from the detectors, to compensate for drift in the gain characteristics, including means for passing a reference signal. (U.K.)

  13. Preclinical validation of automated dual-energy X-ray absorptiometry and computed tomography-based body composition measurements

    International Nuclear Information System (INIS)

    DEVRIESE, Joke; Pottel, Hans; BEELS, Laurence; VAN DE WIELE, Christophe; MAES, Alex; GHEYSENS, Olivier

    2016-01-01

    The aim of this study was to determine and validate a set of Hounsfield unit (HU) ranges to segment computed tomography (CT) images into tissue types and to test the validity of dual-energy X-ray absorptiometry (DXA) tissue segmentation on pure, unmixed porcine tissues. This preclinical prospective study was approved by the local ethical committee. Different quantities of porcine bone tissue (BT), lean tissue (LT) and adipose tissue (AT) were scanned using DXA and CT. Tissue type segmentation in DXA was performed via the standard clinical protocol and in CT through different sets of HU ranges. Percent coefficients of variation (%CV) were used to assess precision while % differences of observed masses were tested against zero using the Wilcoxon signed-rank Test. Total mass DXA measurements differ little but significantly (P=0.016) from true mass, while total mass CT measurements based on literature values show non-significant (P=0.69) differences of 1.7% and 2.0%. BT mass estimates with DXA differed more from true mass (median -78.2 to -75.8%) than other tissue types (median -11.3 to -8.1%). Tissue mass estimates with CT and literature HU ranges showed small differences from true mass for every tissue type (median -10.4 to 8.8%). The most suited method for automated tissue segmentation is CT and can become a valuable tool in quantitative nuclear medicine.

  14. A Novel Approach to Simulation-Based Education for Veterinary Medical Communication Training Over Eight Consecutive Pre-Clinical Quarters.

    Science.gov (United States)

    Englar, Ryane E

    Experiential learning through the use of standardized patients (SPs) is the primary way by which human medical schools teach clinical communication. The profession of veterinary medicine has followed suit in response to new graduates' and their employers' concerns that veterinary interpersonal skills are weak and unsatisfactory. As a result, standardized clients (SCs) are increasingly relied upon as invaluable teaching tools within veterinary curricula to advance relationship-centered care in the context of a clinical scenario. However, there is little to no uniformity in the approach that various colleges of veterinary medicine take when designing simulation-based education (SBE). A further complication is that programs with pre-conceived curricula must now make room for training in clinical communication. Curricular time constraints challenge veterinary colleges to individually decide how best to utilize SCs in what time is available. Because it is a new program, Midwestern University College of Veterinary Medicine (MWU CVM) has had the flexibility and the freedom to prioritize an innovative approach to SBE. The author discusses the SBE that is currently underway at MWU CVM, which incorporates 27 standardized client encounters over eight consecutive pre-clinical quarters. Prior to entering clinical rotations, MWU CVM students are exposed to a variety of simulation formats, species, clients, settings, presenting complaints, and communication tasks. These represent key learning opportunities for students to practice clinical communication, develop self-awareness, and strategize their approach to future clinical experiences.

  15. Introduction to curved rotary tomographic apparatus 'TOMOREX'

    International Nuclear Information System (INIS)

    Kubota, Kazuo; Shinojima, Masayasu; Kohirasawa, Hideo; Tokui, Mitsuru

    1980-01-01

    In recent years, panorama X-ray photographic method is widely used for the X-ray diagnosis of teeth, jawbones and faces. One type based on the principle of tomography is curved surface rotary tomographic method utilizing fine-gap X-ray beam. With the synchronous rotation of an X-ray tube and a photographic film around a face, describing a U-shaped tomographic plane along a dental arch, an upper or lower jawbone is photographed. In the ''TOMOREX'' belonging to this type, is different tomographic planes are available, so that by selecting any position in advance, the part can be photographed. Furthermore, patients can be subjected to examination as laid on a stretcher. The mechanism and equipment, and the photographic method for eye sockets, cheekbones, upper jaw cavities and stereoscopic images are described. (J.P.N.)

  16. [Applicability of the da Vinci robotic system in the skull base surgical approach. Preclinical investigation].

    Science.gov (United States)

    Fernandez-Nogueras Jimenez, Francisco J; Segura Fernandez-Nogueras, Miguel; Jouma Katati, Majed; Arraez Sanchez, Miguel Ángel; Roda Murillo, Olga; Sánchez Montesinos, Indalecio

    2015-01-01

    The role of robotic surgery is well established in various specialties such as urology and general surgery, but not in others such as neurosurgery and otolaryngology. In the case of surgery of the skull base, it has just emerged from an experimental phase. To investigate possible applications of the da Vinci surgical robot in transoral skull base surgery, comparing it with the authors' experience using conventional endoscopic transnasal surgery in the same region. A transoral transpalatal approach to the nasopharynx and medial skull base was performed on 4 cryopreserved cadaver heads. We used the da Vinci robot, a 30° standard endoscope 12mm thick, dual camera and dual illumination, Maryland forceps on the left terminal and curved scissors on the right, both 8mm thick. Bone drilling was performed manually. For the anatomical study of this region, we used 0.5cm axial slices from a plastinated cadaver head. Various skull base structures at different depths were reached with relative ease with the robot terminals Transoral robotic surgery with the da Vinci system provides potential advantages over conventional endoscopic transnasal surgery in the surgical approach to this region. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  17. A Method of Developing and Introducing Case-Based Learning to a Preclinical Veterinary Curriculum

    Science.gov (United States)

    Crowther, Emma; Baillie, Sarah

    2016-01-01

    Case-based learning (CBL) has been introduced as part of a major review of the veterinary curriculum at the University of Bristol. The initial aim was to improve integration between all first year subjects, i.e., basic science disciplines (anatomy, physiology, and biochemistry), animal management, and professional studies, while highlighting the…

  18. Development of full-field x-ray phase-tomographic microscope based on laboratory x-ray source

    Science.gov (United States)

    Takano, H.; Wu, Y.; Momose, A.

    2017-09-01

    An X-ray phase tomographic microscope that can quantitatively measure the refractive index of a sample in three dimensions with a high spatial resolution was developed by installing a Lau interferometer consisting of an absorption grating and a π/2 phase grating into the optics of an X-ray microscope. The optics comprises a Cu rotating anode X-ray source, capillary condenser optics, and a Fresnel zone plate for the objective. The microscope has two optical modes: a large-field-of-view mode (field of view: 65 μm x 65 μm) and a high-resolution mode (spatial resolution: 50 nm). Optimizing the parameters of the interferometer yields a self-image of the phase grating with 60% visibility. Through the normal fringe-scanning measurement, a twin phase image, which has an overlap of two phase image of opposite contrast with a shear distance much larger than system resolution, is generated. Although artifacts remain to some extent currently when a phase image is calculated from the twin phase image, this system can obtain high-spatial-resolution images resolving 50-nm structures. Phase tomography with this system has also been demonstrated using a phase object.

  19. Axial tomographic scanner

    International Nuclear Information System (INIS)

    1976-01-01

    An axial tomographic system is described comprising axial tomographic means for collecting sets of data corresponding to the transmission or absorption of a number of beams of penetrating radiation through a planar slice of an object. It includes means to locate an object to be analyzed, a source and detector for directing one or more beams of penetrating radiation through the object from the source to the detector, and means to rotate (and optionally translate) the source as well as means to process the collected sets of data. Data collection, data processing, and data display can each be conducted independently of each other. An additional advantage of the system described is that the raw data (i.e., the originally collected data) are not destroyed by the data processing but instead are retained intact for further reference or use, if needed

  20. Tomographic method and apparatus

    International Nuclear Information System (INIS)

    Moore, R.M.

    1981-01-01

    A tomographic x-ray machine has a camera and film-plane section which move about a primary axis for imaging a selected cross-section of an anatomical member onto the film. A ''scout image'' of the member is taken at right angles to the plane of the desired cross-section to indicate the cross-section's angle with respect to the primary axis. The film plane is then located at the same angle with respect to a film cassette axis as the selected cross-section makes with the primary axis. The film plane and the cross-section are then maintained in parallel planes throughout motion of the camera and film plane during tomographic radiography. (author)

  1. ERP-based detection of brain pathology in rat models for preclinical Alzheimer's disease

    Science.gov (United States)

    Nouriziabari, Seyed Berdia

    Early pathological features of Alzheimer's disease (AD) include the accumulation of hyperphosphorylated tau protein (HP-tau) in the entorhinal cortex and progressive loss of basal forebrain (BF) cholinergic neurons. These pathologies are known to remain asymptomatic for many years before AD is clinically diagnosed; however, they may induce aberrant brain processing which can be captured as an abnormality in event-related potentials (ERPs). Here, we examined cortical ERPs while a differential associative learning paradigm was applied to adult male rats with entorhinal HP-tau, pharmacological blockade of muscarinic acetylcholine receptors, or both conditions. Despite no impairment in differential associative and reversal learning, each pathological feature induced distinct abnormality in cortical ERPs to an extent that was sufficient for machine classifiers to accurately detect a specific type of pathology based on these ERP features. These results highlight a potential use of ERPs during differential associative learning as a biomarker for asymptomatic AD pathology.

  2. Novel self-expandable, stent-based transcatheter pulmonic valve: a preclinical animal study.

    Science.gov (United States)

    Kim, Gi Beom; Lim, Hong-Gook; Kim, Yong Jin; Choi, Eun Young; Kwon, Bo Sang; Jeong, Saeromi

    2014-04-15

    Because transcatheter implantation of pulmonary valve is indicated for limited-size dysfunctional right ventricular outflow tract only as a balloon-expandable stent, we investigated the feasibility of a large-diameter self-expandable valved stent and the durability of the valve after >6 months. We made a nitinol-wire-based, self-expandable valved stent with leaflets made from porcine pericardium. The porcine pericardium was treated with α-galactosidase, glutaraldehyde, and glycine after decellularization. After cutting the inguinal or cervical area, we implanted a valved stent in 12 sheep through the femoral or jugular vein by using an 18-Fr delivery catheter, controlling the catheter handles and hook block under fluoroscopic and echocardiographic guidance. The mean body weight of sheep was 43.9 kg. We successfully implanted valved stents (diameter: 24 mm in 7 sheep, 26 mm in 5 sheep) in good position in 8 sheep, in the main pulmonary artery (PA) in 2 sheep, and in the right ventricular outlet tract (RVOT) in 2 sheep. We sacrificed 8 sheep (6 sheep in good position, 1 sheep in the main PA, and 1 sheep in the RVOT) after >6 months. Five of the 6 sheep implanted in good position showed well-preserved valve morphology at the time of sacrifice. Histologic findings after routine sacrifice showed well-maintained collagen wave structure and no visible calcification in all explanted valve leaflets. Transcatheter implantation of a nitinol-wire-based, self-expandable valved stent in the pulmonic valve was feasible, and stents implanted in good position showed well-preserved valve leaflets with functional competence in the mid-term results. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. Pre-Clinical Cell-Based Therapy for Limbal Stem Cell Deficiency.

    Science.gov (United States)

    Sehic, Amer; Utheim, Øygunn Aass; Ommundsen, Kristoffer; Utheim, Tor Paaske

    2015-08-28

    The cornea is essential for normal vision by maintaining transparency for light transmission. Limbal stem cells, which reside in the corneal periphery, contribute to the homeostasis of the corneal epithelium. Any damage or disease affecting the function of these cells may result in limbal stem cell deficiency (LSCD). The condition may result in both severe pain and blindness. Transplantation of ex vivo cultured cells onto the cornea is most often an effective therapeutic strategy for LSCD. The use of ex vivo cultured limbal epithelial cells (LEC), oral mucosal epithelial cells, and conjunctival epithelial cells to treat LSCD has been explored in humans. The present review focuses on the current state of knowledge of the many other cell-based therapies of LSCD that have so far exclusively been explored in animal models as there is currently no consensus on the best cell type for treating LSCD. Major findings of all these studies with special emphasis on substrates for culture and transplantation are systematically presented and discussed. Among the many potential cell types that still have not been used clinically, we conclude that two easily accessible autologous sources, epidermal stem cells and hair follicle-derived stem cells, are particularly strong candidates for future clinical trials.

  4. Tomographic image reconstruction using training images

    DEFF Research Database (Denmark)

    Soltani, Sara; Andersen, Martin Skovgaard; Hansen, Per Christian

    2017-01-01

    We describe and examine an algorithm for tomographic image reconstruction where prior knowledge about the solution is available in the form of training images. We first construct a non-negative dictionary based on prototype elements from the training images; this problem is formulated within...

  5. Evaluation of interpolation methods for surface-based motion compensated tomographic reconstruction for cardiac angiographic C-arm data

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Kerstin; Schwemmer, Chris; Hornegger, Joachim [Pattern Recognition Lab, Department of Computer Science, Erlangen Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Erlangen 91058 (Germany); Zheng Yefeng; Wang Yang [Imaging and Computer Vision, Siemens Corporate Research, Princeton, New Jersey 08540 (United States); Lauritsch, Guenter; Rohkohl, Christopher; Maier, Andreas K. [Siemens AG, Healthcare Sector, Forchheim 91301 (Germany); Schultz, Carl [Thoraxcenter, Erasmus MC, Rotterdam 3000 (Netherlands); Fahrig, Rebecca [Department of Radiology, Stanford University, Stanford, California 94305 (United States)

    2013-03-15

    all experiments showed that TPS interpolation provided the best results. The quantitative results in the phantom experiments showed comparable nRMSE of Almost-Equal-To 0.047 {+-} 0.004 for the TPS and Shepard's method. Only slightly inferior results for the smoothed weighting function and the linear approach were achieved. The UQI resulted in a value of Almost-Equal-To 99% for all four interpolation methods. On clinical human data sets, the best results were clearly obtained with the TPS interpolation. The mean contour deviation between the TPS reconstruction and the standard FDK reconstruction improved in the three human cases by 1.52, 1.34, and 1.55 mm. The Dice coefficient showed less sensitivity with respect to variations in the ventricle boundary. Conclusions: In this work, the influence of different motion interpolation methods on left ventricle motion compensated tomographic reconstructions was investigated. The best quantitative reconstruction results of a phantom, a porcine, and human clinical data sets were achieved with the TPS approach. In general, the framework of motion estimation using a surface model and motion interpolation to a dense MVF provides the ability for tomographic reconstruction using a motion compensation technique.

  6. Evaluation of interpolation methods for surface-based motion compensated tomographic reconstruction for cardiac angiographic C-arm data

    International Nuclear Information System (INIS)

    Müller, Kerstin; Schwemmer, Chris; Hornegger, Joachim; Zheng Yefeng; Wang Yang; Lauritsch, Günter; Rohkohl, Christopher; Maier, Andreas K.; Schultz, Carl; Fahrig, Rebecca

    2013-01-01

    experiments showed that TPS interpolation provided the best results. The quantitative results in the phantom experiments showed comparable nRMSE of ≈0.047 ± 0.004 for the TPS and Shepard's method. Only slightly inferior results for the smoothed weighting function and the linear approach were achieved. The UQI resulted in a value of ≈ 99% for all four interpolation methods. On clinical human data sets, the best results were clearly obtained with the TPS interpolation. The mean contour deviation between the TPS reconstruction and the standard FDK reconstruction improved in the three human cases by 1.52, 1.34, and 1.55 mm. The Dice coefficient showed less sensitivity with respect to variations in the ventricle boundary. Conclusions: In this work, the influence of different motion interpolation methods on left ventricle motion compensated tomographic reconstructions was investigated. The best quantitative reconstruction results of a phantom, a porcine, and human clinical data sets were achieved with the TPS approach. In general, the framework of motion estimation using a surface model and motion interpolation to a dense MVF provides the ability for tomographic reconstruction using a motion compensation technique.

  7. Perceived Benefits of Pre-Clinical Simulation-based Training on Clinical Learning Outcomes among Omani Undergraduate Nursing Students

    Directory of Open Access Journals (Sweden)

    Girija Madhavanprabhakaran

    2015-01-01

    Full Text Available Objectives: This study aimed to explore the benefits perceived by Omani undergraduate maternity nursing students regarding the effect of pre-clinical simulation-based training (PSBT on clinical learning outcomes. Methods: This non-experimental quantitative survey was conducted between August and December 2012 among third-year baccalaureate nursing students at Sultan Qaboos University in Muscat, Oman. Voluntary participants were exposed to faculty-guided PSBT sessions using low- and medium-fidelity manikins, standardised scenarios and skill checklists on antenatal, intranatal, postnatal and newborn care and assessment. Participants answered a purposely designed self-administered questionnaire on the benefits of PSBT in enhancing learning outcomes. Items were categorised into six subscales: knowledge, skills, patient safety, academic safety, confidence and satisfaction. Scores were rated on a four-point Likert scale. Results: Of the 57 participants, the majority (95.2% agreed that PSBT enhanced their knowledge. Most students (94.3% felt that their patient safety practices improved and 86.5% rated PSBT as beneficial for enhancing skill competencies. All male students and 97% of the female students agreed that PSBT enhanced their confidence in the safe holding of newborns. Moreover, 93% of participants were satisfied with PSBT. Conclusion: Omani undergraduate nursing students perceived that PSBT enhanced their knowledge, skills, patient safety practices and confidence levels in providing maternity care. These findings support the use of simulation training as a strategy to facilitate clinical learning outcomes in future nursing courses in Oman, although further research is needed to explore the objective impact of PSBT on learning outcomes.

  8. The Japan Lung Cancer Society–Japanese Society for Radiation Oncology consensus-based computed tomographic atlas for defining regional lymph node stations in radiotherapy for lung cancer

    International Nuclear Information System (INIS)

    Itazawa, Tomoko; Tamaki, Yukihisa; Komiyama, Takafumi; Nishimura, Yasumasa; Nakayama, Yuko; Ito, Hiroyuki; Ohde, Yasuhisa; Kusumoto, Masahiko; Sakai, Shuji; Suzuki, Kenji; Watanabe, Hirokazu; Asamura, Hisao

    2017-01-01

    The purpose of this study was to develop a consensus-based computed tomographic (CT) atlas that defines lymph node stations in radiotherapy for lung cancer based on the lymph node map of the International Association for the Study of Lung Cancer (IASLC). A project group in the Japanese Radiation Oncology Study Group (JROSG) initially prepared a draft of the atlas in which lymph node Stations 1–11 were illustrated on axial CT images. Subsequently, a joint committee of the Japan Lung Cancer Society (JLCS) and the Japanese Society for Radiation Oncology (JASTRO) was formulated to revise this draft. The committee consisted of four radiation oncologists, four thoracic surgeons and three thoracic radiologists. The draft prepared by the JROSG project group was intensively reviewed and discussed at four meetings of the committee over several months. Finally, we proposed definitions for the regional lymph node stations and the consensus-based CT atlas. This atlas was approved by the Board of Directors of JLCS and JASTRO. This resulted in the first official CT atlas for defining regional lymph node stations in radiotherapy for lung cancer authorized by the JLCS and JASTRO. In conclusion, the JLCS–JASTRO consensus-based CT atlas, which conforms to the IASLC lymph node map, was established.

  9. Pulmonary lymphatic drainage to the mediastinum based on computed tomographic observations of the primary complex of pulmonary histoplasmosis

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Koji; Sasaki, Tomoaki; Nabaa, Basim; Aburano, Tamio (Department of Radiology, Asahikawa Medical University and Hospital, Asahikawa (Japan)), Email: taka1019@asahikawa-med.ac.jp; Beek, Edwin Jr. von (Clinical Research Imaging Centre, Queen' s Medical Research Institute, University of Edinburgh, Edinburgh (United Kingdom)); Stanford, William (Department of Radiology, University of Iowa College of Medicine, Iowa City (United States))

    2012-03-15

    Background. In the primary infection of pulmonary histoplasmosis, pulmonary lesions are commonly solitary and associated with hilar and/or mediastinal nodal diseases, which spontaneously resolve, resulting in calcifications in individuals with normal cellular immunity. Purpose. To assess the lymphatic drainage to the mediastinum from each pulmonary segment and lobe using computed tomographic (CT) observations of a calcified primary complex pulmonary histoplasmosis and predict which patients with N2 disease that would benefit from surgery. Material and Methods. We collected 585 CT studies of patients with primary complex histoplasmosis consisting of solitary calcified pulmonary lesions and calcified hilar and/or mediastinal nodal disease. Using the N stage criteria of non-small cell lung cancer, we assessed the distribution of the involved hilar and mediastinal nodes depending on the pulmonary segment of the lesion, with a focus on skip involvement. We also assessed the correlation between the incidence of N1and skip N2 involvement and the mean number of involved mediastinal nodal stations in the non-skip N2 and skip N2 groups. Results. Skip involvement was common in the apical segment (9/45, 20.0%), posterior segment (7/31, 22.6%), and mediolbasal segment (13/20, 65.0%) in the right lung, and in the apicoposterior segment (7/55, 12.7%), lateral basal segment (6/26, 23.1%), and posterobasal segment (16/47, 34.0%) in the left lung. The incidence of skip involvement in each segment showed a significant inverse correlation with that of N1 involvement (r = -0.51, P <0.05) in both lungs. The mean number of involved mediastinal nodal stations in the non-skip N2 and skip N2 groups in all segments of both lungs were 1.4 (434/301) and 1.2 (93/77), and the former was significantly greater than the latter (P <0.01). Conclusion. Our data showed a predictable pattern of segmental and lobar lymphatic drainage to the mediastinum and suggested that skip involvement could represent

  10. Pulmonary lymphatic drainage to the mediastinum based on computed tomographic observations of the primary complex of pulmonary histoplasmosis

    International Nuclear Information System (INIS)

    Takahashi, Koji; Sasaki, Tomoaki; Nabaa, Basim; Aburano, Tamio; Beek, Edwin Jr. von; Stanford, William

    2012-01-01

    Background. In the primary infection of pulmonary histoplasmosis, pulmonary lesions are commonly solitary and associated with hilar and/or mediastinal nodal diseases, which spontaneously resolve, resulting in calcifications in individuals with normal cellular immunity. Purpose. To assess the lymphatic drainage to the mediastinum from each pulmonary segment and lobe using computed tomographic (CT) observations of a calcified primary complex pulmonary histoplasmosis and predict which patients with N2 disease that would benefit from surgery. Material and Methods. We collected 585 CT studies of patients with primary complex histoplasmosis consisting of solitary calcified pulmonary lesions and calcified hilar and/or mediastinal nodal disease. Using the N stage criteria of non-small cell lung cancer, we assessed the distribution of the involved hilar and mediastinal nodes depending on the pulmonary segment of the lesion, with a focus on skip involvement. We also assessed the correlation between the incidence of N1and skip N2 involvement and the mean number of involved mediastinal nodal stations in the non-skip N2 and skip N2 groups. Results. Skip involvement was common in the apical segment (9/45, 20.0%), posterior segment (7/31, 22.6%), and mediolbasal segment (13/20, 65.0%) in the right lung, and in the apicoposterior segment (7/55, 12.7%), lateral basal segment (6/26, 23.1%), and posterobasal segment (16/47, 34.0%) in the left lung. The incidence of skip involvement in each segment showed a significant inverse correlation with that of N1 involvement (r = -0.51, P <0.05) in both lungs. The mean number of involved mediastinal nodal stations in the non-skip N2 and skip N2 groups in all segments of both lungs were 1.4 (434/301) and 1.2 (93/77), and the former was significantly greater than the latter (P <0.01). Conclusion. Our data showed a predictable pattern of segmental and lobar lymphatic drainage to the mediastinum and suggested that skip involvement could represent

  11. Voxel-based model construction from colored tomographic images; Construcao de simuladores baseados em elementos de volume a partir de imagens tomograficas coloridas

    Energy Technology Data Exchange (ETDEWEB)

    Loureiro, Eduardo Cesar de Miranda

    2002-07-01

    This work presents a new approach in the construction of voxel-based phantoms that was implemented to simplify the segmentation process of organs and tissues reducing the time used in this procedure. The segmentation process is performed by painting tomographic images and attributing a different color for each organ or tissue. A voxel-based head and neck phantom was built using this new approach. The way as the data are stored allows an increasing in the performance of the radiation transport code. The program that calculates the radiation transport also works with image files. This capability allows image reconstruction showing isodose areas, under several points of view, increasing the information to the user. Virtual X-ray photographs can also be obtained allowing that studies could be accomplished looking for the radiographic techniques optimization assessing, at the same time, the doses in organs and tissues. The accuracy of the program here presented, called MCvoxEL, that implements this new approach, was tested by comparison to results from two modern and well-supported Monte Carlo codes. Dose conversion factors for parallel X-ray exposure were also calculated. (author)

  12. "Glowing head" mice: a genetic tool enabling reliable preclinical image-based evaluation of cancers in immunocompetent allografts.

    Directory of Open Access Journals (Sweden)

    Chi-Ping Day

    Full Text Available Preclinical therapeutic assessment currently relies on the growth response of established human cell lines xenografted into immunocompromised mice, a strategy that is generally not predictive of clinical outcomes. Immunocompetent genetically engineered mouse (GEM-derived tumor allograft models offer highly tractable preclinical alternatives and facilitate analysis of clinically promising immunomodulatory agents. Imageable reporters are essential for accurately tracking tumor growth and response, particularly for metastases. Unfortunately, reporters such as luciferase and GFP are foreign antigens in immunocompetent mice, potentially hindering tumor growth and confounding therapeutic responses. Here we assessed the value of reporter-tolerized GEMs as allograft recipients by targeting minimal expression of a luciferase-GFP fusion reporter to the anterior pituitary gland (dubbed the "Glowing Head" or GH mouse. The luciferase-GFP reporter expressed in tumor cells induced adverse immune responses in wildtype mouse, but not in GH mouse, as transplantation hosts. The antigenicity of optical reporters resulted in a decrease in both the growth and metastatic potential of the labeled tumor in wildtype mice as compared to the GH mice. Moreover, reporter expression can also alter the tumor response to chemotherapy or targeted therapy in a context-dependent manner. Thus the GH mice and experimental approaches vetted herein provide concept validation and a strategy for effective, reproducible preclinical evaluation of growth and response kinetics for traceable tumors.

  13. “Glowing Head” Mice: A Genetic Tool Enabling Reliable Preclinical Image-Based Evaluation of Cancers in Immunocompetent Allografts

    Science.gov (United States)

    Day, Chi-Ping; Carter, John; Ohler, Zoe Weaver; Bonomi, Carrie; El Meskini, Rajaa; Martin, Philip; Graff-Cherry, Cari; Feigenbaum, Lionel; Tüting, Thomas; Van Dyke, Terry; Hollingshead, Melinda; Merlino, Glenn

    2014-01-01

    Preclinical therapeutic assessment currently relies on the growth response of established human cell lines xenografted into immunocompromised mice, a strategy that is generally not predictive of clinical outcomes. Immunocompetent genetically engineered mouse (GEM)-derived tumor allograft models offer highly tractable preclinical alternatives and facilitate analysis of clinically promising immunomodulatory agents. Imageable reporters are essential for accurately tracking tumor growth and response, particularly for metastases. Unfortunately, reporters such as luciferase and GFP are foreign antigens in immunocompetent mice, potentially hindering tumor growth and confounding therapeutic responses. Here we assessed the value of reporter-tolerized GEMs as allograft recipients by targeting minimal expression of a luciferase-GFP fusion reporter to the anterior pituitary gland (dubbed the “Glowing Head” or GH mouse). The luciferase-GFP reporter expressed in tumor cells induced adverse immune responses in wildtype mouse, but not in GH mouse, as transplantation hosts. The antigenicity of optical reporters resulted in a decrease in both the growth and metastatic potential of the labeled tumor in wildtype mice as compared to the GH mice. Moreover, reporter expression can also alter the tumor response to chemotherapy or targeted therapy in a context-dependent manner. Thus the GH mice and experimental approaches vetted herein provide concept validation and a strategy for effective, reproducible preclinical evaluation of growth and response kinetics for traceable tumors. PMID:25369133

  14. High resolution tomographic instrument development

    International Nuclear Information System (INIS)

    1992-01-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational

  15. High resolution tomographic instrument development

    Energy Technology Data Exchange (ETDEWEB)

    1992-08-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  16. High resolution tomographic instrument development

    Energy Technology Data Exchange (ETDEWEB)

    1992-01-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  17. Computerized tomographic system

    International Nuclear Information System (INIS)

    Godbarsen, R.; Barrett, D.M.; Garrott, P.M.; Foley, L.E.; Redington, R.W.; Lambert, T.W.; Edelheit, L.S.

    1981-01-01

    A computerized tomographic system for examining human breasts is described in detail. Conventional X-ray scanning apparatus has difficulty in achieving the levels of image definition and examination speeds required for mass screening. A novel method of scanning successive layers of the breast with a rotating X-ray beam is discussed and details of the control circuitry and sequence steps are given. The method involves immersing the breast in an inner fluid (e.g. water) filled container which is stationary during an examination and is surrounded by a large outer container which is also filled with the fluid; the inner and outer containers are always maintained at a constant height and the X-ray absorption across the fan-shaped beam is as close as possible to constant. (U.K.)

  18. Emission computed tomograph

    International Nuclear Information System (INIS)

    Hirose, Y.; Kanno, I.; Koga, K.; Miura, S.; Uemura, K.

    1981-01-01

    Emission computed tomograph wherein a pluralty of detectors surround an object to be examined so as to detect x- or gamma radiation emitted by said object. In front of each of said detectors there is provided a collimator which comprises a pair of main plates and a subsidiary plate interposed therebetween. The plates are made of a material capable of blocking penetration of the radiation therethrough and so supported as to be swingable over an angle sufficient to cover the whole of said object. The plates of all the collimators are simultaneously swung to the same side and at the same angular speed thereby to change the direction of incidence of said radiation on each of said detectors

  19. Tomographic examination table

    International Nuclear Information System (INIS)

    Redington, R.W.; Henkes, J.L.

    1979-01-01

    Equipment is described for positioning and supporting patients during tomographic mammography using X-rays. The equipment consists of a table and fabric slings which permit the examination of a downward, pendant breast of a prone patient by allowing the breast to pass through a aperture in the table into a fluid filled container. The fluid has an X-ray absorption coefficient similar to that of soft human tissue allowing high density resolution radiography and permitting accurate detection of breast tumours. The shape of the equipment and the positioning of the patient allow the detector and X-ray source to rotate 360 0 about a vertical axis through the breast. This permits the use of relatively simple image reconstruction algorithms and a divergent X-ray geometry. (UK)

  20. Tomographic Approach in Three-Orthogonal-Basis Quantum Key Distribution

    International Nuclear Information System (INIS)

    Liang Wen-Ye; Yin Zhen-Qiang; Chen Hua; Li Hong-Wei; Chen Wei; Han Zheng-Fu; Wen Hao

    2015-01-01

    At present, there is an increasing awareness of some three-orthogonal-basis quantum key distribution protocols, such as, the reference-frame-independent (RFI) protocol and the six-state protocol. For secure key rate estimations of these protocols, there are two methods: one is the conventional approach, and another is the tomographic approach. However, a comparison between these two methods has not been given yet. In this work, with the general model of rotation channel, we estimate the key rate using conventional and tomographic methods respectively. Results show that conventional estimation approach in RFI protocol is equivalent to tomographic approach only in the case of that one of three orthogonal bases is always aligned. In other cases, tomographic approach performs much better than the respective conventional approaches of the RFI protocol and the six-state protocol. Furthermore, based on the experimental data, we illustrate the deep connections between tomography and conventional RFI approach representations. (paper)

  1. Imaging performance of LabPET APD-based digital PET scanners for pre-clinical research

    International Nuclear Information System (INIS)

    Bergeron, Mélanie; Cadorette, Jules; Beaudoin, Jean-François; Lecomte, Roger; Tétrault, Marc-André; Leroux, Jean-Daniel; Fontaine, Réjean

    2014-01-01

    The LabPET is an avalanche photodiode (APD) based digital PET scanner with quasi-individual detector read-out and highly parallel electronic architecture for high-performance in vivo molecular imaging of small animals. The scanner is based on LYSO and LGSO scintillation crystals (2×2×12/14 mm 3 ), assembled side-by-side in phoswich pairs read out by an APD. High spatial resolution is achieved through the individual and independent read-out of an individual APD detector for recording impinging annihilation photons. The LabPET exists in three versions, LabPET4 (3.75 cm axial length), LabPET8 (7.5 cm axial length) and LabPET12 (11.4 cm axial length). This paper focuses on the systematic characterization of the three LabPET versions using two different energy window settings to implement a high-efficiency mode (250–650 keV) and a high-resolution mode (350–650 keV) in the most suitable operating conditions. Prior to measurements, a global timing alignment of the scanners and optimization of the APD operating bias have been carried out. Characteristics such as spatial resolution, absolute sensitivity, count rate performance and image quality have been thoroughly investigated following the NEMA NU 4-2008 protocol. Phantom and small animal images were acquired to assess the scanners' suitability for the most demanding imaging tasks in preclinical biomedical research. The three systems achieve the same radial FBP spatial resolution at 5 mm from the field-of-view center: 1.65/3.40 mm (FWHM/FWTM) for an energy threshold of 250 keV and 1.51/2.97 mm for an energy threshold of 350 keV. The absolute sensitivity for an energy window of 250–650 keV is 1.4%/2.6%/4.3% for LabPET4/8/12, respectively. The best count rate performance peaking at 362 kcps is achieved by the LabPET12 with an energy window of 250–650 keV and a mouse phantom (2.5 cm diameter) at an activity of 2.4 MBq ml −1 . With the same phantom, the scatter fraction for all scanners is about

  2. Image interface in Java for tomographic reconstruction in nuclear medicine

    International Nuclear Information System (INIS)

    Andrade, M.A.; Silva, A.M. Marques da

    2004-01-01

    The aim of this study is to implement a software for tomographic reconstruction of SPECT data from Nuclear Medicine with a flexible interface design, cross-platform, written in Java. Validation tests were performed based on SPECT simulated data. The results showed that the implemented algorithms and filters agree with the theoretical context. We intend to extend the system by implementing additional tomographic reconstruction techniques and Java threads, in order to provide simultaneously image processing. (author)

  3. Preclinical and Clinical Development of a YFV 17 D-Based Chimeric Vaccine against West Nile Virus

    Directory of Open Access Journals (Sweden)

    Gustavo H. Dayan

    2013-12-01

    Full Text Available Substantial success has been achieved in the development and implementation of West Nile (WN vaccines for horses; however, no human WN vaccines are approved. This review focuses on the construction, pre-clinical and clinical characterization of ChimeriVax-WN02 for humans, a live chimeric vaccine composed of a yellow fever (YF 17D virus in which the prM-E envelope protein genes are replaced with the corresponding genes of the WN NY99 virus. Pre-clinical studies demonstrated that ChimeriVax-WN02 was significantly less neurovirulent than YF 17D in mice and rhesus and cynomolgus monkeys. The vaccine elicited neutralizing antibody titers after inoculation in hamsters and monkeys and protected immunized animals from lethal challenge including intracerebral inoculation of high dose of WN NY99 virus. Safety, viremia and immunogenicity of ChimeriVax-WN02 were assessed in one phase I study and in two phase II clinical trials. No safety signals were detected in the three clinical trials with no remarkable differences in incidence of adverse events (AEs between vaccine and placebo recipients. Viremia was transient and the mean viremia levels were low. The vaccine elicited strong and durable neutralizing antibody and cytotoxic T cell responses. WN epidemiology impedes a classical licensure pathway; therefore, innovative licensure strategies should be explored.

  4. Simultaneous determination of sample thickness, tilt, and electron mean free path using tomographic tilt images based on Beer-Lambert law.

    Science.gov (United States)

    Yan, Rui; Edwards, Thomas J; Pankratz, Logan M; Kuhn, Richard J; Lanman, Jason K; Liu, Jun; Jiang, Wen

    2015-11-01

    Cryo-electron tomography (cryo-ET) is an emerging technique that can elucidate the architecture of macromolecular complexes and cellular ultrastructure in a near-native state. Some important sample parameters, such as thickness and tilt, are needed for 3-D reconstruction. However, these parameters can currently only be determined using trial 3-D reconstructions. Accurate electron mean free path plays a significant role in modeling image formation process essential for simulation of electron microscopy images and model-based iterative 3-D reconstruction methods; however, their values are voltage and sample dependent and have only been experimentally measured for a limited number of sample conditions. Here, we report a computational method, tomoThickness, based on the Beer-Lambert law, to simultaneously determine the sample thickness, tilt and electron inelastic mean free path by solving an overdetermined nonlinear least square optimization problem utilizing the strong constraints of tilt relationships. The method has been extensively tested with both stained and cryo datasets. The fitted electron mean free paths are consistent with reported experimental measurements. The accurate thickness estimation eliminates the need for a generous assignment of Z-dimension size of the tomogram. Interestingly, we have also found that nearly all samples are a few degrees tilted relative to the electron beam. Compensation of the intrinsic sample tilt can result in horizontal structure and reduced Z-dimension of tomograms. Our fast, pre-reconstruction method can thus provide important sample parameters that can help improve performance of tomographic reconstruction of a wide range of samples. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Preclinical evaluation of IL2-based immunocytokines supports their use in combination with dacarbazine, paclitaxel and TNF-based immunotherapy.

    Science.gov (United States)

    Pretto, Francesca; Elia, Giuliano; Castioni, Nadia; Neri, Dario

    2014-09-01

    Antibody-cytokine fusion proteins ("immunocytokines") represent a promising class of armed antibody products, which allow the selective delivery of potent pro-inflammatory payloads at the tumor site. The antibody-based selective delivery of interleukin-2 (IL2) is particularly attractive for the treatment of metastatic melanoma, an indication for which this cytokine received marketing approval from the US Food and drug administration. We used the K1735M2 immunocompetent syngeneic model of murine melanoma to study the therapeutic activity of F8-IL2, an immunocytokine based on the F8 antibody in diabody format, fused to human IL2. F8-IL2 was shown to selectively localize at the tumor site in vivo, following intravenous administration, and to mediate tumor growth retardation, which was potentiated by the combination with paclitaxel or dacarbazine. Combination treatment led to a substantially more effective tumor growth inhibition, compared to the cytotoxic drugs used as single agents, without additional toxicity. Analysis of the immune infiltrate revealed a significant accumulation of CD4(+) T cells 24 h after the administration of the combination. The fusion proteins F8-IL2 and L19-IL2, specific to the alternatively spliced extra domain A and extra domain B of fibronectin respectively, were also studied in combination with tumor necrosis factor (TNF)-based immunocytokines. The combination treatment was superior to the action of the individual immunocytokines and was able to eradicate neoplastic lesions after a single intratumoral injection, a procedure that is being clinically used for the treatment of Stage IIIC melanoma. Collectively, these data reinforce the rationale for the use of IL2-based immunocytokines in combination with cytotoxic agents or TNF-based immunotherapy for the treatment of melanoma patients.

  6. Application of Powell's analogy for the prediction of vortex-pairing sound in a low-Mach number jet based on time-resolved planar and tomographic PIV

    NARCIS (Netherlands)

    Violato, D.; Bryon, K.; Moore, P.; Scarano, F.

    2010-01-01

    This paper describes an experimental investigation by time-resolved planar and tomographic PIV on the sound production mechanism of vortex pairing of a transitional water-jet flow at Re=5000. The shear layer is characterized by axisymmetric vortex rings which undergo pairing with a varicose mode.

  7. Tomographic multiphase flow measurement

    International Nuclear Information System (INIS)

    Sætre, C.; Johansen, G.A.; Tjugum, S.A.

    2012-01-01

    Measurement of multiphase flow of gas, oil and water is not at all trivial and in spite of considerable achievements over the past two decades, important challenges remain (). These are related to reducing measurement uncertainties arising from variations in the flow regime, improving long term stability and developing new means for calibration, adjustment and verification of the multiphase flow meters. This work focuses on the first two issues using multi gamma beam (MGB) measurements for identification of the type of flow regime. Further gamma ray tomographic measurements are used for reference of the gas/liquid distribution. For the MGB method one Am-241 source with principal emission at 59.5 keV is used because this relatively low energy enables efficient collimation and thereby shaping of the beams, as well as compact detectors. One detector is placed diametrically opposite the source whereas the second is positioned to the side so that this beam is close to the pipe wall. The principle is then straight forward to compare the measured intensities of these detectors and through that identify the flow pattern, i.e. the instantaneous cross-sectional gas-liquid distribution. The measurement setup also includes Compton scattering measurements, which can provide information about the changes in the water salinity for flow segments with high water liquid ratio and low gas fractions. By measuring the transmitted intensity in short time slots (<100ms), rapid regime variations are revealed. From this we can select the time sections suitable for salinity measurements. Since the salinity variations change at the time scale of hours, a running average can be performed to increase the accuracy of the measurements. Recent results of this work will be presented here. - Highlights: ► Multiphase flow gas-fraction and flow regime measurements by multi gamma ray beams. ► High-speed gamma ray tomograph as reference for the flow pattern and gas fraction. ► Dual modality

  8. Tomographic multiphase flow measurement

    Energy Technology Data Exchange (ETDEWEB)

    Saetre, C., E-mail: camilla@ift.uib.no [Department of Physics and Technology, University of Bergen (Norway); Michelsen Centre for Industrial Measurement Science and Technology (Norway); Johansen, G.A. [Department of Physics and Technology, University of Bergen (Norway); Michelsen Centre for Industrial Measurement Science and Technology (Norway); Tjugum, S.A. [Michelsen Centre for Industrial Measurement Science and Technology (Norway); Roxar Flow Measurement, Bergen (Norway)

    2012-07-15

    Measurement of multiphase flow of gas, oil and water is not at all trivial and in spite of considerable achievements over the past two decades, important challenges remain (). These are related to reducing measurement uncertainties arising from variations in the flow regime, improving long term stability and developing new means for calibration, adjustment and verification of the multiphase flow meters. This work focuses on the first two issues using multi gamma beam (MGB) measurements for identification of the type of flow regime. Further gamma ray tomographic measurements are used for reference of the gas/liquid distribution. For the MGB method one Am-241 source with principal emission at 59.5 keV is used because this relatively low energy enables efficient collimation and thereby shaping of the beams, as well as compact detectors. One detector is placed diametrically opposite the source whereas the second is positioned to the side so that this beam is close to the pipe wall. The principle is then straight forward to compare the measured intensities of these detectors and through that identify the flow pattern, i.e. the instantaneous cross-sectional gas-liquid distribution. The measurement setup also includes Compton scattering measurements, which can provide information about the changes in the water salinity for flow segments with high water liquid ratio and low gas fractions. By measuring the transmitted intensity in short time slots (<100ms), rapid regime variations are revealed. From this we can select the time sections suitable for salinity measurements. Since the salinity variations change at the time scale of hours, a running average can be performed to increase the accuracy of the measurements. Recent results of this work will be presented here. - Highlights: Black-Right-Pointing-Pointer Multiphase flow gas-fraction and flow regime measurements by multi gamma ray beams. Black-Right-Pointing-Pointer High-speed gamma ray tomograph as reference for the flow

  9. A Study on GPU-based Iterative ML-EM Reconstruction Algorithm for Emission Computed Tomographic Imaging Systems

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Woo Seok; Kim, Soo Mee; Park, Min Jae; Lee, Dong Soo; Lee, Jae Sung [Seoul National University, Seoul (Korea, Republic of)

    2009-10-15

    The maximum likelihood-expectation maximization (ML-EM) is the statistical reconstruction algorithm derived from probabilistic model of the emission and detection processes. Although the ML-EM has many advantages in accuracy and utility, the use of the ML-EM is limited due to the computational burden of iterating processing on a CPU (central processing unit). In this study, we developed a parallel computing technique on GPU (graphic processing unit) for ML-EM algorithm. Using Geforce 9800 GTX+ graphic card and CUDA (compute unified device architecture) the projection and backprojection in ML-EM algorithm were parallelized by NVIDIA's technology. The time delay on computations for projection, errors between measured and estimated data and backprojection in an iteration were measured. Total time included the latency in data transmission between RAM and GPU memory. The total computation time of the CPU- and GPU-based ML-EM with 32 iterations were 3.83 and 0.26 sec, respectively. In this case, the computing speed was improved about 15 times on GPU. When the number of iterations increased into 1024, the CPU- and GPU-based computing took totally 18 min and 8 sec, respectively. The improvement was about 135 times and was caused by delay on CPU-based computing after certain iterations. On the other hand, the GPU-based computation provided very small variation on time delay per iteration due to use of shared memory. The GPU-based parallel computation for ML-EM improved significantly the computing speed and stability. The developed GPU-based ML-EM algorithm could be easily modified for some other imaging geometries

  10. A Study on GPU-based Iterative ML-EM Reconstruction Algorithm for Emission Computed Tomographic Imaging Systems

    International Nuclear Information System (INIS)

    Ha, Woo Seok; Kim, Soo Mee; Park, Min Jae; Lee, Dong Soo; Lee, Jae Sung

    2009-01-01

    The maximum likelihood-expectation maximization (ML-EM) is the statistical reconstruction algorithm derived from probabilistic model of the emission and detection processes. Although the ML-EM has many advantages in accuracy and utility, the use of the ML-EM is limited due to the computational burden of iterating processing on a CPU (central processing unit). In this study, we developed a parallel computing technique on GPU (graphic processing unit) for ML-EM algorithm. Using Geforce 9800 GTX+ graphic card and CUDA (compute unified device architecture) the projection and backprojection in ML-EM algorithm were parallelized by NVIDIA's technology. The time delay on computations for projection, errors between measured and estimated data and backprojection in an iteration were measured. Total time included the latency in data transmission between RAM and GPU memory. The total computation time of the CPU- and GPU-based ML-EM with 32 iterations were 3.83 and 0.26 sec, respectively. In this case, the computing speed was improved about 15 times on GPU. When the number of iterations increased into 1024, the CPU- and GPU-based computing took totally 18 min and 8 sec, respectively. The improvement was about 135 times and was caused by delay on CPU-based computing after certain iterations. On the other hand, the GPU-based computation provided very small variation on time delay per iteration due to use of shared memory. The GPU-based parallel computation for ML-EM improved significantly the computing speed and stability. The developed GPU-based ML-EM algorithm could be easily modified for some other imaging geometries

  11. SU-E-I-83: Error Analysis of Multi-Modality Image-Based Volumes of Rodent Solid Tumors Using a Preclinical Multi-Modality QA Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Y [University of Kansas Hospital, Kansas City, KS (United States); Fullerton, G; Goins, B [University of Texas Health Science Center at San Antonio, San Antonio, TX (United States)

    2015-06-15

    Purpose: In our previous study a preclinical multi-modality quality assurance (QA) phantom that contains five tumor-simulating test objects with 2, 4, 7, 10 and 14 mm diameters was developed for accurate tumor size measurement by researchers during cancer drug development and testing. This study analyzed the errors during tumor volume measurement from preclinical magnetic resonance (MR), micro-computed tomography (micro- CT) and ultrasound (US) images acquired in a rodent tumor model using the preclinical multi-modality QA phantom. Methods: Using preclinical 7-Tesla MR, US and micro-CT scanners, images were acquired of subcutaneous SCC4 tumor xenografts in nude rats (3–4 rats per group; 5 groups) along with the QA phantom using the same imaging protocols. After tumors were excised, in-air micro-CT imaging was performed to determine reference tumor volume. Volumes measured for the rat tumors and phantom test objects were calculated using formula V = (π/6)*a*b*c where a, b and c are the maximum diameters in three perpendicular dimensions determined by the three imaging modalities. Then linear regression analysis was performed to compare image-based tumor volumes with the reference tumor volume and known test object volume for the rats and the phantom respectively. Results: The slopes of regression lines for in-vivo tumor volumes measured by three imaging modalities were 1.021, 1.101 and 0.862 for MRI, micro-CT and US respectively. For phantom, the slopes were 0.9485, 0.9971 and 0.9734 for MRI, micro-CT and US respectively. Conclusion: For both animal and phantom studies, random and systematic errors were observed. Random errors were observer-dependent and systematic errors were mainly due to selected imaging protocols and/or measurement method. In the animal study, there were additional systematic errors attributed to ellipsoidal assumption for tumor shape. The systematic errors measured using the QA phantom need to be taken into account to reduce measurement

  12. Development of a tomographic system adapted to 3D measurement of contaminated wounds based on the Cacao concept (Computer aided collimation Gamma Camera)

    International Nuclear Information System (INIS)

    Douiri, A.

    2002-03-01

    The computer aided collimation gamma camera (CACAO in French) is a gamma camera using a collimator with large holes, a supplementary linear scanning motion during the acquisition and a dedicated reconstruction program taking full account of the source depth. The CACAO system was introduced to improve both the sensitivity and the resolution in nuclear medicine. This thesis focuses on the design of a fast and robust reconstruction algorithm in the CACAO project. We start by an overview of tomographic imaging techniques in nuclear medicine. After modelling the physical CACAO system, we present the complete reconstruction program which involves three steps: 1) shift and sum 2) deconvolution and filtering 3) rotation and sum. The deconvolution is the critical step that decreases the signal to noise ratio of the reconstructed images. We propose a regularized multi-channel algorithm to solve the deconvolution problem. We also present a fast algorithm based on Splines functions and preserving the high quality of the reconstructed images for the shift and the rotation steps. Comparisons of simulated reconstructed images in 2D and 3D for the conventional system (CPHC) and CACAO demonstrate the ability of CACAO system to increase the quality of the SPECT images. Finally, this study concludes with an experimental approach with a pixellated detector conceived for a 3D measurement of contaminated wounds. This experimentation proves the possible advantages of coupling the CACAO project with pixellated detectors. Moreover, a variety of applications could fully benefit from the CACAO system, such as low activity imaging, the use of high-energy gamma isotopes and the visualization of deep organs. Moreover the combination of the CACAO system with a pixels detector may open up further possibilities for the future of nuclear medicine. (author)

  13. A single photon emission computed tomograph based on a limited dumber of detectors for fluid flow visualization

    International Nuclear Information System (INIS)

    Legoupil, S.

    1999-01-01

    We present in this work a method for fluid flow visualization in a system using radioactive tracers. The method is based on single photon emission computed tomography techniques, applied to a limited number of discrete detectors. We propose in this work a method for the estimation of the transport matrix of photons, associated to the acquisition system. This method is based on the modelization of profiles acquired for a set of point sources located in the imaged volume. Monte Carlo simulations allow to separate scattered photons from those directly collected by the system. The influence of the energy tracer is exposed. The reconstruction method is based on the maximum likelihood - expectation maximization algorithm. An experimental device, based on 36 detectors was realised for the visualization of water circulation in a vessel. A video monitoring allows to visualize the dye water tracer. Dye and radioactive tracers are injected simultaneously in a water flow circulating in the vessel. Reconstructed and video images are compared. Quantitative and qualitative analysis show that fluid flow visualization is feasible with a limited number of detectors. This method can be applied for system involving circulations of fluids. (author)

  14. Tomographic extreme-ultraviolet spectrographs: TESS.

    Science.gov (United States)

    Cotton, D M; Stephan, A; Cook, T; Vickers, J; Taylor, V; Chakrabarti, S

    2000-08-01

    We describe the system of Tomographic Extreme Ultraviolet (EUV) SpectrographS (TESS) that are the primary instruments for the Tomographic Experiment using Radiative Recombinative Ionospheric EUV and Radio Sources (TERRIERS) satellite. The spectrographs were designed to make high-sensitivity {80 counts/s)/Rayleigh [one Rayleigh is equivalent to 10(6) photons/(4pi str cm(2)s)}, line-of-sight measurements of the oi 135.6- and 91.1-nm emissions suitable for tomographic inversion. The system consists of five spectrographs, four identical nightglow instruments (for redundancy and added sensitivity), and one instrument with a smaller aperture to reduce sensitivity and increase spectral resolution for daytime operation. Each instrument has a bandpass of 80-140 nm with approximately 2- and 1-nm resolution for the night and day instruments, respectively. They utilize microchannel-plate-based two-dimensional imaging detectors with wedge-and-strip anode readouts. The instruments were designed, fabricated, and calibrated at Boston University, and the TERRIERS satellite was launched on 18 May 1999 from Vandenberg Air Force Base, California.

  15. In Vivo Murine-Matured Human CD3+ Cells as a Preclinical Model for T Cell-Based Immunotherapies

    Directory of Open Access Journals (Sweden)

    Kevin G. Haworth

    2017-09-01

    Full Text Available Adoptive cellular immunotherapy is a promising and powerful method for the treatment of a broad range of malignant and infectious diseases. Although the concept of cellular immunotherapy was originally proposed in the 1990s, it has not seen successful clinical application until recent years. Despite significant progress in creating engineered receptors against both malignant and viral epitopes, no efficient preclinical animal models exist for rapidly testing and directly comparing these engineered receptors. The use of matured human T cells in mice usually leads to graft-versus-host disease (GvHD, which severely limits the effectiveness of such studies. Alternatively, adult apheresis CD34+ cells engraft in neonatal non-obese diabetic (NOD-severe combined immunodeficiency (SCID-common γ chain–/– (NSG mice and lead to the development of CD3+ T cells in peripheral circulation. We demonstrate that these in vivo murine-matured autologous CD3+ T cells from humans (MATCH can be collected from the mice, engineered with lentiviral vectors, reinfused into the mice, and detected in multiple lymphoid compartments at stable levels over 50 days after injection. Unlike autologous CD3+ cells collected from human donors, these MATCH mice did not exhibit GvHD after T cell administration. This novel mouse model offers the opportunity to screen different immunotherapy-based treatments in a preclinical setting.

  16. Algorithm for three dimension reconstruction of magnetic resonance tomographs and X-ray images based on Fast Fourier Transform

    International Nuclear Information System (INIS)

    Bueno, Josiane M.; Traina, Agma Juci M.; Cruvinel, Paulo E.

    1995-01-01

    This work presents an algorithm for three-dimensional digital image reconstruction. Such algorithms based on the combination of both a Fast Fourier Transform method with Hamming Window and the use of a tri-linear interpolation function. The algorithm allows not only the generation of three-dimensional spatial spin distribution maps for Magnetic Resonance Tomography data but also X and Y-rays linear attenuation coefficient maps for CT scanners. Results demonstrates the usefulness of the algorithm in three-dimensional image reconstruction by doing first two-dimensional reconstruction and rather after interpolation. The algorithm was developed in C++ language, and there are two available versions: one under the DOS environment, and the other under the UNIX/Sun environment. (author)

  17. Computed tomographic findings in dogs with head trauma and development of a novel prognostic computed tomography-based scoring system.

    Science.gov (United States)

    Chai, Orit; Peery, Dana; Bdolah-Abram, Tali; Moscovich, Efrat; Kelmer, Efrat; Klainbart, Sigal; Milgram, Joshua; Shamir, Merav H

    2017-09-01

    OBJECTIVE To characterize CT findings and outcomes in dogs with head trauma and design a prognostic scale. ANIMALS 27 dogs admitted to the Koret School Veterinary Teaching Hospital within 72 hours after traumatic head injury that underwent CT imaging of the head. PROCEDURES Data were extracted from medical records regarding dog signalment, history, physical and neurologic examination findings, and modified Glasgow coma scale scores. All CT images were retrospectively evaluated by a radiologist unaware of dog status. Short-term (10 days after trauma) and long-term (≥ 6 months after trauma) outcomes were determined, and CT findings and other variables were analyzed for associations with outcome. A prognostic CT-based scale was developed on the basis of the results. RESULTS Cranial vault fractures, parenchymal abnormalities, or both were identified via CT in 24 of 27 (89%) dogs. Three (11%) dogs had only facial bone fractures. Intracranial hemorrhage was identified in 16 (59%) dogs, cranial vault fractures in 15 (56%), midline shift in 14 (52%), lateral ventricle asymmetry in 12 (44%), and hydrocephalus in 7 (26%). Hemorrhage and ventricular asymmetry were significantly and negatively associated with short- and long-term survival, respectively. The developed 7-point prognostic scale included points for hemorrhage, midline shift or lateral ventricle asymmetry, cranial vault fracture, and depressed fracture (1 point each) and infratentorial lesion (3 points). CONCLUSIONS AND CLINICAL RELEVANCE The findings reported here may assist in determining prognoses for other dogs with head trauma. The developed scale may be useful for outcome assessment of dogs with head trauma; however, it must be validated before clinical application.

  18. Tomographic imaging system

    International Nuclear Information System (INIS)

    Hayakawa, T.; Horiba, I.; Kohno, H.; Nakaya, C.; Sekihara, K.; Shiono, H.; Tomura, T.; Yamamoto, S.; Yanaka, S.

    1980-01-01

    A tomographic imaging system comprising: irradiating means for irradating a cross-section of an object under consideration with radiation rays from plural directions; detector means for detecting the radiation rays transmitted through the cross-section of said object to produce an output signal; first memory means for storing the output signal of said detector means; and an image jreconstructing section for performing a convolution integral operation on the contents of said first memory means by means of a first weighting function to reconstruct a three-dimensional image of the cross-section of said object, said image reconstructing section including (I) second memory means for storing a second weighting function, said second weighting function being provided with a predetermined positive and negative (N-1)th order when the output signal of said detector means produced by the irradiation of the cross-section of said object from one of said plural directions is sampled by N points, the value of the (N-1)th order of said second weighting function being an integration of said first weighting function from the (N-1)th order to positive infinity and the value of -(N-1)th order of said second weighting function being an integration of said first weighting function from the -(N-1)th order to negative infinity, (II) control means for successively reading out the contents of said first and second memory means, and (III) operational means for performing multiplying and summing operations on the read-out contents of said first and second memory means, said operational means producing the product of the values fo the (N-1)th and -(N-1)th orders of said second weighting function and a component of the output signal of said detector means relating to the radiation rays free from the absorption thereof by said object

  19. Tomographic PIV: particles versus blobs

    International Nuclear Information System (INIS)

    Champagnat, Frédéric; Cornic, Philippe; Besnerais, Guy Le; Plyer, Aurélien; Cheminet, Adam; Leclaire, Benjamin

    2014-01-01

    We present an alternative approach to tomographic particle image velocimetry (tomo-PIV) that seeks to recover nearly single voxel particles rather than blobs of extended size. The baseline of our approach is a particle-based representation of image data. An appropriate discretization of this representation yields an original linear forward model with a weight matrix built with specific samples of the system’s point spread function (PSF). Such an approach requires only a few voxels to explain the image appearance, therefore it favors much more sparsely reconstructed volumes than classic tomo-PIV. The proposed forward model is general and flexible and can be embedded in a classical multiplicative algebraic reconstruction technique (MART) or a simultaneous multiplicative algebraic reconstruction technique (SMART) inversion procedure. We show, using synthetic PIV images and by way of a large exploration of the generating conditions and a variety of performance metrics, that the model leads to better results than the classical tomo-PIV approach, in particular in the case of seeding densities greater than 0.06 particles per pixel and of PSFs characterized by a standard deviation larger than 0.8 pixels. (paper)

  20. Magnetic particle imaging: from proof of principle to preclinical applications

    Science.gov (United States)

    Knopp, T.; Gdaniec, N.; Möddel, M.

    2017-07-01

    Tomographic imaging has become a mandatory tool for the diagnosis of a majority of diseases in clinical routine. Since each method has its pros and cons, a variety of them is regularly used in clinics to satisfy all application needs. Magnetic particle imaging (MPI) is a relatively new tomographic imaging technique that images magnetic nanoparticles with a high spatiotemporal resolution in a quantitative way, and in turn is highly suited for vascular and targeted imaging. MPI was introduced in 2005 and now enters the preclinical research phase, where medical researchers get access to this new technology and exploit its potential under physiological conditions. Within this paper, we review the development of MPI since its introduction in 2005. Besides an in-depth description of the basic principles, we provide detailed discussions on imaging sequences, reconstruction algorithms, scanner instrumentation and potential medical applications.

  1. TU-H-CAMPUS-TeP2-03: High Sensitivity and High Resolution Fiber Based Micro-Detector for Sub-Millimeter Preclinical Dosimetry

    International Nuclear Information System (INIS)

    Izaguirre, E; Pokhrel, S; Knewtson, T; Hedrick, S

    2016-01-01

    Purpose: Current precision of small animal and cell micro-irradiators has continuously increased during the past years. Currently, preclinical irradiators can deliver sub-millimeter fields with micrometric precision but there are no water equivalent dosimeters to determine small field profiles and dose in the orthovoltage range of energies with micrometric resolution and precision. We have developed a fiber based micro-dosimeter with the resolution and dosimetric accuracy required for radiobiological research. Methods: We constructed two prototypes of micro-dosimeters based on different compositions of fiber scintillators to study the spatial resolution and dosimetric precision of small animal and cell micro-irradiators. The first has green output and the second has blue output. The blue output dosimeter has the highest sensitivity because it matches the spectral sensitivity of silicon photomultipliers. A blue detector with 500um cross section was built and tested respect to a CC01 ion chamber, film, and the 1500um green output detector. Orthovoltage fields from 1×1mm2 to 5×5mm2 were used for detector characteristics comparison. Results: The blue fiber dosimeter shows great agreement with films and matches dose measurements with the gold-standard ion chamber for 5×5mm2 fields. The detector has the appropriate sensitivity to measure fields from 1×1mm2 to larger sizes with a 1% dosimetric accuracy. The spatial resolution is in the sub-millimeter range and the spectral matching with the photomultiplier allows reducing the sensor cross section even further than the presented prototype. These results suggest that scintillating fibers combined with silicon photomultipliers is the appropriate technology to pursue micro-dosimetry for small animals and disperse cell samples. Conclusion: The constructed detectors establish a new landmark for the resolution and sensitivity of fiber based microdetectors. The validation of the detector in our small animal and cell

  2. Computer tomographic diagnosis of echinococcosis

    Energy Technology Data Exchange (ETDEWEB)

    Haertel, M.; Fretz, C.; Fuchs, W.A.

    1980-08-01

    The computer tomographic appearances and differential diagnosis in 22 patients with echinococcosis are described; of these, twelve were of the cystic and ten of the alveolar type. The computer tomographic appearances are characterised by the presence of daughter cysts (66%) within the sharply demarkated parasitic cyst of water density. In the absence of daughter cysts, a definite aetiological diagnosis cannot be made, although there is a tendency to clasification of the occassionally multiple echinococcus cysts. The computer tomographic appearances of advanced alveolar echinococcosis are characterised by partial collequative necrosis, with clacification around the necrotic areas (90%). The absence of CT evidence of partial necrosis and calsification of the pseudotumour makes it difficult to establish a specific diagnosis. The conclusive and non-invasive character of the procedure and its reproducibility makes computer tomography the method of choice for the diagnosis and follow-up of echinococcosis.

  3. Classification of brain tumors using texture based analysis of T1-post contrast MR scans in a preclinical model

    Science.gov (United States)

    Tang, Tien T.; Zawaski, Janice A.; Francis, Kathleen N.; Qutub, Amina A.; Gaber, M. Waleed

    2018-02-01

    Accurate diagnosis of tumor type is vital for effective treatment planning. Diagnosis relies heavily on tumor biopsies and other clinical factors. However, biopsies do not fully capture the tumor's heterogeneity due to sampling bias and are only performed if the tumor is accessible. An alternative approach is to use features derived from routine diagnostic imaging such as magnetic resonance (MR) imaging. In this study we aim to establish the use of quantitative image features to classify brain tumors and extend the use of MR images beyond tumor detection and localization. To control for interscanner, acquisition and reconstruction protocol variations, the established workflow was performed in a preclinical model. Using glioma (U87 and GL261) and medulloblastoma (Daoy) models, T1-weighted post contrast scans were acquired at different time points post-implant. The tumor regions at the center, middle, and peripheral were analyzed using in-house software to extract 32 different image features consisting of first and second order features. The extracted features were used to construct a decision tree, which could predict tumor type with 10-fold cross-validation. Results from the final classification model demonstrated that middle tumor region had the highest overall accuracy at 79%, while the AUC accuracy was over 90% for GL261 and U87 tumors. Our analysis further identified image features that were unique to certain tumor region, although GL261 tumors were more homogenous with no significant differences between the central and peripheral tumor regions. In conclusion our study shows that texture features derived from MR scans can be used to classify tumor type with high success rates. Furthermore, the algorithm we have developed can be implemented with any imaging datasets and may be applicable to multiple tumor types to determine diagnosis.

  4. Design and Effectiveness of a Required Pre-Clinical Simulation-based Curriculum for Fundamental Clinical Skills and Procedures

    Directory of Open Access Journals (Sweden)

    Daryl P. Lofaso

    2011-12-01

    Full Text Available For more than 20 years, medical literature has increasingly documented the need for students to learn, practice and demonstrate competence in basic clinical knowledge and skills. In 2001, the Louisiana State University Health Science Centers (LSUHSC School of Medicine – New Orleans replaced its traditional Introduction in to Clinical Medicine (ICM course with the Science and Practice of Medicine (SPM course. The main component within the SPM course is the Clinical Skills Lab (CSL. The CSL teaches 30 plus skills to all pre-clinical medical students (Years 1 and 2. Since 2002, an annual longitudinal evaluation questionnaire was distributed to all medical students targeting the skills taught in the CSL. Students were asked to rate their self- confidence (Dreyfus and Likert-type and estimate the number of times each clinical skill was performed (clinically/non-clinically. Of the 30 plus skills taught, 8 were selected for further evaluation. An analysis was performed on the eight skills selected to determine the effectiveness of the CSL. All students that participated in the CSL reported a significant improvement in self-confidence and in number performed in the clinically/non-clinically setting when compared to students that did not experience the CSL. For example, without CSL training, the percentage of students reported at the end of their second year self-perceived expertise as “novice” ranged from 21.4% (CPR to 84.7% (GU catheterization. Students who completed the two-years CSL, only 7.8% rated their self-perceived expertise at the end of the second year as “novice” and 18.8% for GU catheterization. The CSL design is not to replace real clinical patient experiences. It's to provide early exposure, medial knowledge, professionalism and opportunity to practice skills in a patient free environment.

  5. Tomographic methods in nuclear medicine

    International Nuclear Information System (INIS)

    Ahluwalia, B.D.

    1989-01-01

    This book is a review of the various approaches to tomographic imaging that have been pursued in nuclear medicine. The evolution of single photon emission computed tomography (SPECT) is discussed in detail, and the major classes of instrumentation are represented. A section on positron emission tomography is also included, but is rather brief and may serve only as a general introduction

  6. Original circuitry for TOHR tomograph

    International Nuclear Information System (INIS)

    Cuzon, J.C.; Pinot, L.

    1999-01-01

    Having industrialization in mind, a specific electronics for a high resolution tomograph is designed out of the usual standards of nuclear physics. All the information are converted in the time domain and a fast processor, in front of the data acquisition, carries out the time and energy coincidences. (authors)

  7. A tomograph VMEbus parallel processing data acquisition system

    International Nuclear Information System (INIS)

    Wilkinson, N.A.; Rogers, J.G.; Atkins, M.S.

    1989-01-01

    This paper describes a VME based data acquisition system suitable for the development of Positron Volume Imaging tomographs which use 3-D data for improved image resolution over slice-oriented tomographs. the data acquisition must be flexible enough to accommodate several 3-D reconstruction algorithms; hence, a software-based system is most suitable. Furthermore, because of the increased dimensions and resolution of volume imaging tomographs, the raw data event rate is greater than that of slice-oriented machines. These dual requirements are met by our data acquisition system. Flexibility is achieved through an array of processors connected over a VMEbus, operating asynchronously and in parallel. High raw data throughput is achieved using a dedicated high speed data transfer device available for the VMEbus. The device can attain a raw data rate of 2.5 million coincidence events per second for raw events which are 64 bits wide

  8. A case-based, small-group cooperative learning course in preclinical veterinary science aimed at bridging basic science and clinical literacy

    Directory of Open Access Journals (Sweden)

    J.P. Schoeman

    2009-05-01

    Full Text Available In 1999 a dedicated problem-based learning course was introduced into the lecture-based preclinical veterinary curriculum of the University of Pretoria. The Introduction to Clinical Studies Course combines traditional lectures, practical sessions, student self-learning and guided tutorials. The self-directed component of the course utilises case-based, small group cooperative learning as an educational vehicle to link basic science with clinical medicine. The aim of this article is to describe the objectives and structure of the course and to report the results of the assessment of the students' perceptions on some aspects of the course. Students reacted very positively to the ability of the course to equip them with problem-solving skills. Students indicated positive perceptions about the workload of the course. There were, however, significantly lower scores for the clarity of the course objectives. Although the study guide for the course is very comprehensive, the practice regarding the objectives is still uncertain. It is imperative to set clear objectives in non-traditional, student-centred courses. The objectives have to be explained at the outset and reiterated throughout the course. Tutors should also communicate the rationale behind problem based learning as a pedagogical method to the students. Further research is needed to verify the effectiveness of this course in bridging the gap between basic science and clinical literacy in veterinary science. Ongoing feedback and assessment of the management and content are important to refine this model for integrating basic science with clinical literacy.

  9. A case-based, small-group cooperative learning course in preclinical veterinary science aimed at bridging basic science and clinical literacy.

    Science.gov (United States)

    Schoeman, J P; van Schoor, M; van der Merwe, L L; Meintjes, R A

    2009-03-01

    In 1999 a dedicated problem-based learning course was introduced into the lecture-based preclinical veterinary curriculum of the University of Pretoria. The Introduction to Clinical Studies Course combines traditional lectures, practical sessions, student self-learning and guided tutorials. The self-directed component of the course utilises case-based, small-group cooperative learning as an educational vehicle to link basic science with clinical medicine. The aim of this article is to describe the objectives and structure of the course and to report the results of the assessment of the students' perceptions on some aspects of the course. Students reacted very positively to the ability of the course to equip them with problem-solving skills. Students indicated positive perceptions about the workload of the course. There were, however, significantly lower scores for the clarity of the course objectives. Although the study guide for the course is very comprehensive, the practice regarding the objectives is still uncertain. It is imperative to set clear objectives in non-traditional, student-centred courses. The objectives have to be explained at the outset and reiterated throughout the course. Tutors should also communicate the rationale behind problem-based learning as a pedagogical method to the students. Further research is needed to verify the effectiveness of this course in bridging the gap between basic science and clinical literacy in veterinary science. Ongoing feedback and assessment of the management and content are important to refine this model for integrating basic science with clinical literacy.

  10. Computerized tomographic diagnosis of basal skull fracture

    International Nuclear Information System (INIS)

    Tanaka, Tokutaro; Shimoyama, Ichiro; Endoh, Mitsutoshi; Ninchoji, Toshiaki; Uemura, Kenichi.

    1984-01-01

    The diagnosis of basal skull fractures used to be difficult, particularly on the basis of routine skull roentgenography alone. We have now examined the diagnostic value of conventional computerized tomography in basal skull fractures. We studied 82 cases clinically diagnosed as basal skull fractures. We examined them based on at least one of the following computerized tomographic criteria for basal skull fractures: 1) fracture line(s), 2) intracranial air, 3) fluid in the paranasal sinuses, and 4) fluid in the middle ear, including the mastoid air cells. The signs of the fracture line and of the intracranial air are definite indications of basal skull fracture, but the signs of fluid in the paranasal sinuses and/or in the middle ear are not definite. When combined, however, with such other clinical signs as black eye, Battle's sign, CSF leakage, CSF findings, and profuse nasal or ear bleeding, the diagnosis is more reliable. Seventy cases (85.4%) in this series had basal skull fractures according to our computerized tomographic criteria. Among them , 26 cases (31.7%) were diagnosed with fracture lines, 17 cases (20.7%) with intracranial air, 16 cases (19.5%) with fluid in the paranasal sinuses, 10 cases (12.2%) with fluid in the middle ear, and one case (1.2%) with fluid in both. Twelve cases (14.6%) of the 82 cases clinically diagnosed as basal skull fractures could not have been diagnosed on our computerized tomographic criteria alone. We diagnosed them because of CSF leakage, CSF findings, surgical findings, etc. (author)

  11. Concept and benefits of the Inverted Classroom method for a competency-based biochemistry course in the pre-clinical stage of a human medicine course of studies.

    Science.gov (United States)

    Kühl, Susanne J; Toberer, Matthias; Keis, Oliver; Tolks, Daniel; Fischer, Martin R; Kühl, Michael

    2017-01-01

    Background: Medical students often have a problem recognising the relevance of basic science subjects for their later professional work in the pre-clinical stage of their studies. This can lead to a lower motivation to learn biochemical content and dissatisfaction in the courses amongst the students. Alternative teaching methods such as the Inverted Classroom (IC) method can address this deficiency. The goal of this study was: to analyse the motivation and satisfaction of the students in a biochemistry seminar through the use of the e-learning-based IC method, to investigate the acceptance against the IC teaching method in biochemistry, and to compare the learning success achieved using the IC approach with that of a traditional course. We also investigated how a biochemistry course in the pre-clinical stage of a human medicine course of studies can be successfully organised according to the IC method. Furthermore, we examined the benefits of the IC method over conventional teaching formats. Method: The IC method was implemented in accordance with the guidelines of the GMA committee "New Media" [30] in a biochemistry seminar for two student IC intervention groups with 42 students. A part of the factual knowledge from the on-site phase in the form of teaching videos together with self-learning control tasks were provided online before the seminar for both IC intervention groups. Exporting content to the self-learning phase creates new free time in the on-site phase, during which the content can be critically considered and processed and additional competency-based learning objectives can be taught. Identical biochemistry teaching content was taught in parallel control groups (14 student groups with n=299 students), but no material was handed out beforehand for a self-learning phase. These students only received the materials after the on-site phase. Motivation and satisfaction as well as the acceptance for the teaching methods were recorded by questionnaires, the

  12. Initial preclinical safety of non-replicating human endogenous retrovirus envelope protein-coated baculovirus vector-based vaccines against human papillomavirus.

    Science.gov (United States)

    Han, Su-Eun; Kim, Mi-Gyeong; Lee, Soondong; Cho, Hee-Jeong; Byun, Youngro; Kim, Sujeong; Kim, Young Bong; Choi, Yongseok; Oh, Yu-Kyoung

    2013-12-01

    Human endogenous retrovirus (HERV) envelope protein-coated, baculovirus vector-based HPV 16 L1 (AcHERV-HPV16L1) is a non-replicating recombinant baculoviral vaccine. Here, we report an initial evaluation of the preclinical safety of AcHERV-HPV16L1 vaccine. In an acute toxicity study, a single administration of AcHERV-HPV16L1 DNA vaccine given intramuscularly (i.m.) to mice at a dose of 1 × 10(8) plaque-forming units (PFU) did not cause significant changes in body weight compared with vehicle-treated controls. It did cause a brief increase in the weights of some organs on day 15 post-treatment, but by day 30, all organ weights were not significantly different from those in the vehicle-treated control group. No hematological changes were observed on day 30 post-treatment. In a range-finding toxicity study with three doses of 1 × 10(7) , 2 × 10(7) and 5 × 10(7) PFU once daily for 5 days, the group treated with 5 × 10(7) PFU showed a transient decrease in the body weights from day 5 to day 15 post-treatment, but recovery to the levels similar to those in the vehicle-treated control group by post-treatment day 20. Organ weights were slightly higher for lymph nodes, spleen, thymus and liver after repeated dosing with 5 × 10(7) PFU on day 15, but had normalized by day 30. Moreover, repeated administration of AcHERV-HPV16L1 did not induce myosin-specific autoantibody in serum, and did not cause immune complex deposition or tissue damage at injection sites. Taken together, these results provide preliminary evidence of the preclinical safety of AcHERV-based HPV16L1 DNA vaccines in mice. Copyright © 2012 John Wiley & Sons, Ltd.

  13. Concept and benefits of the Inverted Classroom method for a competency-based biochemistry course in the pre-clinical stage of a human medicine course of studies

    Directory of Open Access Journals (Sweden)

    Kühl, Susanne J.

    2017-08-01

    Full Text Available Background: Medical students often have a problem recognising the relevance of basic science subjects for their later professional work in the pre-clinical stage of their studies. This can lead to a lower motivation to learn biochemical content and dissatisfaction in the courses amongst the students. Alternative teaching methods such as the Inverted Classroom (IC method can address this deficiency. The goal of this study was: We also investigated how a biochemistry course in the pre-clinical stage of a human medicine course of studies can be successfully organised according to the IC method. Furthermore, we examined the benefits of the IC method over conventional teaching formats. Method: The IC method was implemented in accordance with the guidelines of the GMA committee “New Media” in a biochemistry seminar for two student IC intervention groups with 42 students. A part of the factual knowledge from the on-site phase in the form of teaching videos together with self-learning control tasks were provided online before the seminar for both IC intervention groups. Exporting content to the self-learning phase creates new free time in the on-site phase, during which the content can be critically considered and processed and additional competency-based learning objectives can be taught. Identical biochemistry teaching content was taught in parallel control groups (14 student groups with n=299 students, but no material was handed out beforehand for a self-learning phase. These students only received the materials after the on-site phase. Motivation and satisfaction as well as the acceptance for the teaching methods were recorded by questionnaires, the acquisition of knowledge by MC exams.Results: On a Likert scale from 1 (strongly disagree to 6 (strongly agree, the students in the IC intervention groups could be seen to be much more motivated (5.53 than students in the control group (4.01. Students in the IC intervention groups also recognised the

  14. Preclinical and clinical safety studies on DNA vaccines.

    NARCIS (Netherlands)

    Schalk, Johanna A C; Mooi, Frits R; Berbers, Guy A M; Aerts, Leon A G J M van; Ovelgönne, Hans; Kimman, Tjeerd G

    2007-01-01

    DNA vaccines are based on the transfer of genetic material, encoding an antigen, to the cells of the vaccine recipient. Despite high expectations of DNA vaccines as a result of promising preclinical data their clinical utility remains unproven. However, much data is gathered in preclinical and

  15. Computed tomographic appearances of cherubism

    Energy Technology Data Exchange (ETDEWEB)

    Bianchi, S D; Boccardi, A; Mela, F; Romagnoli, R

    1987-01-01

    The computed tomographic (CT) aspects of six cases of cherubism are described. Through its optimal representation of the lesions, CT enabled certain characteristics of this disease to be substantiated, namely, limitation of the process to the bones of the jaw and primarily superficial development of the mandibular lesions, coupled with an unusual mandibular condylar impairment. Moreover, the composition of this series permitted investigation of the condition in its several stages of progression.

  16. Pressure spectra from single-snapshot tomographic PIV

    NARCIS (Netherlands)

    Schneiders, J.F.G.; Avallone, F.; Pröbsting, S.; Ragni, D.; Scarano, F.

    2018-01-01

    The power spectral density and coherence of temporal pressure fluctuations are obtained from low-repetition-rate tomographic PIV measurements. This is achieved by extension of recent single-snapshot pressure evaluation techniques based upon the Taylor’s hypothesis (TH) of frozen turbulence and

  17. X-ray Tomographic Microscopy at TOMCAT

    Energy Technology Data Exchange (ETDEWEB)

    Marone, F; Hintermueller, C; McDonald, S; Abela, R; Mikuljan, G; Isenegger, A; Stampanoni, M, E-mail: federica.marone@psi.c [Swiss Light Source, Paul Scherrer Institut, 5232 Villigen (Switzerland)

    2009-09-01

    Synchrotron-based X-ray Tomographic Microscopy is a powerful technique for fast non-destructive, high resolution quantitative volumetric investigations on diverse samples. At the TOMCAT (TOmographic Microscopy and Coherent rAdiology experimenTs) beamline at the Swiss Light Source, synchrotron light is delivered by a 2.9 T superbend. The main optical component, a Double Crystal Multilayer Monochromator, covers an energy range between 8 and 45 keV. The standard TOMCAT detector offers field of views ranging from 0.75x0.75 mm{sup 2} up to 12.1x12.1 mm{sup 2} with a pixel size of 0.37 {mu}m and 5.92 {mu}m, respectively. In addition to routine measurements, which exploit the absorption contrast, the high coherence of the source also enables phase contrast tomography, implemented with two complementary techniques (Modified Transport of Intensity approach and Grating Interferometry). Typical acquisition times for a tomogram are in the order of few minutes, ensuring high throughput and allowing for semi-dynamical investigations. Raw data are automatically post-processed online and full reconstructed volumes are available shortly after a scan with minimal user intervention.

  18. Pre-Clinical Efficacy and Safety of Experimental Vaccines Based on Non-Replicating Vaccinia Vectors against Yellow Fever

    Science.gov (United States)

    Schäfer, Birgit; Holzer, Georg W.; Joachimsthaler, Alexandra; Coulibaly, Sogue; Schwendinger, Michael; Crowe, Brian A.; Kreil, Thomas R.; Barrett, P. Noel; Falkner, Falko G.

    2011-01-01

    Background Currently existing yellow fever (YF) vaccines are based on the live attenuated yellow fever virus 17D strain (YFV-17D). Although, a good safety profile was historically attributed to the 17D vaccine, serious adverse events have been reported, making the development of a safer, more modern vaccine desirable. Methodology/Principal Findings A gene encoding the precursor of the membrane and envelope (prME) protein of the YFV-17D strain was inserted into the non-replicating modified vaccinia virus Ankara and into the D4R-defective vaccinia virus. Candidate vaccines based on the recombinant vaccinia viruses were assessed for immunogenicity and protection in a mouse model and compared to the commercial YFV-17D vaccine. The recombinant live vaccines induced γ-interferon-secreting CD4- and functionally active CD8-T cells, and conferred full protection against lethal challenge already after a single low immunization dose of 105 TCID50. Surprisingly, pre-existing immunity against wild-type vaccinia virus did not negatively influence protection. Unlike the classical 17D vaccine, the vaccinia virus-based vaccines did not cause mortality following intracerebral administration in mice, demonstrating better safety profiles. Conclusions/Significance The non-replicating recombinant YF candidate live vaccines induced a broad immune response after single dose administration, were effective even in the presence of a pre-existing immunity against vaccinia virus and demonstrated an excellent safety profile in mice. PMID:21931732

  19. Pre-clinical efficacy and safety of experimental vaccines based on non-replicating vaccinia vectors against yellow fever.

    Directory of Open Access Journals (Sweden)

    Birgit Schäfer

    Full Text Available BACKGROUND: Currently existing yellow fever (YF vaccines are based on the live attenuated yellow fever virus 17D strain (YFV-17D. Although, a good safety profile was historically attributed to the 17D vaccine, serious adverse events have been reported, making the development of a safer, more modern vaccine desirable. METHODOLOGY/PRINCIPAL FINDINGS: A gene encoding the precursor of the membrane and envelope (prME protein of the YFV-17D strain was inserted into the non-replicating modified vaccinia virus Ankara and into the D4R-defective vaccinia virus. Candidate vaccines based on the recombinant vaccinia viruses were assessed for immunogenicity and protection in a mouse model and compared to the commercial YFV-17D vaccine. The recombinant live vaccines induced γ-interferon-secreting CD4- and functionally active CD8-T cells, and conferred full protection against lethal challenge already after a single low immunization dose of 10(5 TCID(50. Surprisingly, pre-existing immunity against wild-type vaccinia virus did not negatively influence protection. Unlike the classical 17D vaccine, the vaccinia virus-based vaccines did not cause mortality following intracerebral administration in mice, demonstrating better safety profiles. CONCLUSIONS/SIGNIFICANCE: The non-replicating recombinant YF candidate live vaccines induced a broad immune response after single dose administration, were effective even in the presence of a pre-existing immunity against vaccinia virus and demonstrated an excellent safety profile in mice.

  20. The development of self-regulated learning during the pre-clinical stage of medical school: a comparison between a lecture-based and a problem-based curriculum.

    Science.gov (United States)

    Lucieer, Susanna M; van der Geest, Jos N; Elói-Santos, Silvana M; de Faria, Rosa M Delbone; Jonker, Laura; Visscher, Chris; Rikers, Remy M J P; Themmen, Axel P N

    2016-03-01

    Society expects physicians to always improve their competencies and to be up to date with developments in their field. Therefore, an important aim of medical schools is to educate future medical doctors to become self-regulated, lifelong learners. However, it is unclear if medical students become better self-regulated learners during the pre-clinical stage of medical school, and whether students develop self-regulated learning skills differently, dependent on the educational approach of their medical school. In a cross-sectional design, we investigated the development of 384 medical students' self-regulated learning skills with the use of the Self-Regulation of Learning Self-Report Scale. Next, we compared this development in students who enrolled in two distinct medical curricula: a problem-based curriculum and a lectured-based curriculum. Analysis showed that more skills decreased than increased during the pre-clinical stage of medical school, and that the difference between the curricula was mainly caused by a decrease in the skill evaluation in the lecture-based curriculum. These findings seem to suggest that, irrespective of the curriculum, self-regulated learning skills do not develop during medical school.

  1. Instrumentation for tomograph positioning

    International Nuclear Information System (INIS)

    Frenkel, A.D.B.; Castello Branco, L.M.; Reznik, D.S.; Santos, C.A.C.; Borges, J.C.

    1986-01-01

    The COPPE's Nuclear Instrumentation Lab. has been developing researches directed towards the implementation of a Computer-Based Tomography System. Basically, the system reported in this paper can be divided into three major parts: the mechanical part, responsible for the physical movement (Stepper-Motors, table, etc.); the electronic part, which controls the mechanical part and handles the data-acquisition process (microcomputer, interfaces, etc.); and finally, the support of a software-oriented system, including control programs and information processing routines. (Author) [pt

  2. Team-based learning in a preclinical removable denture prosthesis module in a United Arab Emirates dental school.

    Science.gov (United States)

    Haj-Ali, Reem; Al Quran, Firas

    2013-03-01

    The purpose of this article is to describe the implementation of a team-based learning (TBL) approach in a removable denture prosthesis (RDP) module and present the results of students' performance in individual and group TBL activities and exam scores, students' experience with TBL and end of course evaluations, and faculty feedback. Course material at the College of Dentistry, University of Sharjah, United Arab Emirates, was transformed into seven conventional lectures and seven TBL sessions. Each TBL session consisted of pre-assigned reading (self-directed learning), in-class individual and group readiness tests (accountability), team problem-solving of patient RDP cases, and faculty-led class discussion (knowledge application). The course was assessed through scores from TBL session activities and course examinations, student satisfaction survey, and faculty feedback. Course grades were found to be higher using the TBL method then the traditional lecture-based method. Student evaluation data and faculty response indicated strong support for TBL as it was implemented in the course. The faculty noted a higher level of student engagement with team learning than in conventional class lecturing. TBL is an active-learning instructional strategy for courses with high student-to-faculty ratios. This approach provides regular feedback and the opportunity for students to develop higher reasoning skills.

  3. Recommendations for Benchmarking Preclinical Studies of Nanomedicines.

    Science.gov (United States)

    Dawidczyk, Charlene M; Russell, Luisa M; Searson, Peter C

    2015-10-01

    Nanoparticle-based delivery systems provide new opportunities to overcome the limitations associated with traditional small-molecule drug therapy for cancer and to achieve both therapeutic and diagnostic functions in the same platform. Preclinical trials are generally designed to assess therapeutic potential and not to optimize the design of the delivery platform. Consequently, progress in developing design rules for cancer nanomedicines has been slow, hindering progress in the field. Despite the large number of preclinical trials, several factors restrict comparison and benchmarking of different platforms, including variability in experimental design, reporting of results, and the lack of quantitative data. To solve this problem, we review the variables involved in the design of preclinical trials and propose a protocol for benchmarking that we recommend be included in in vivo preclinical studies of drug-delivery platforms for cancer therapy. This strategy will contribute to building the scientific knowledge base that enables development of design rules and accelerates the translation of new technologies. ©2015 American Association for Cancer Research.

  4. Development of new folate-based PET radiotracers: preclinical evaluation of 68Ga-DOTA-folate conjugates

    International Nuclear Information System (INIS)

    Fani, Melpomeni; Maecke, Helmut R.; Wang, Xuejuan; Nicolas, Guillaume; Medina, Christelle; Raynal, Isabelle; Port, Marc

    2011-01-01

    A number of 111 In- and 99m Tc-folate-based tracers have been evaluated as diagnostic agents for imaging folate receptor (FR)-positive tumours. A 68 Ga-folate-based radiopharmaceutical would be of great interest, combining the advantages of PET technology and the availability of 68 Ga from a generator. The aim of the study was to develop a new 68 Ga-folate-based PET radiotracer. Two new DOTA-folate conjugates, named P3026 and P1254, were synthesized using the 1,2-diaminoethane and 3-{2-[2-(3-amino-propoxy)-ethoxy]-ethoxy}-propylamine as a spacer, respectively. Both conjugates were labelled with 67/68 Ga. Binding affinity, internalization and externalization studies were performed using the FR-positive KB cell line. Biodistribution and PET/CT imaging studies were performed in nude mice, on a folate-deficient diet, bearing KB and HT1080 (FR-negative) tumours, concurrently. The new radiotracers were evaluated comparatively to the reference molecule 111 In-DTPA-folate ( 111 In-P3139). The K d values of 67/68 Ga-P3026 (4.65 ± 0.82 nM) and 67/68 Ga-P1254 (4.27 ± 0.42 nM) showed high affinity for the FR. The internalization rate followed the order 67/68 Ga-P3026 > 67/68 Ga-P1254 > 111 In-P3139, while almost double cellular retention was found for 67/68 Ga-P3026 and 67/68 Ga-P1254, compared to 111 In-P3139. The biodistribution data of 67/68 Ga-DOTA-folates showed high and receptor-mediated uptake on the FR-positive tumours and kidneys, with no significant differences compared to 111 In-P3139. PET/CT images, performed with 68 Ga-P3026, showed high uptake in the kidneys and clear visualization of the FR-positive tumours. The DOTA-folate conjugates can be efficiently labelled with 68 Ga in labelling yields and specific activities which allow clinical application. The characteristics of the 67/68 Ga-DOTA-folates are comparable to 111 In-DTPA-folate, which has already been used in clinical trials, showing that the new conjugates are promising candidates as PET radiotracers

  5. E-learn Computed Tomographic Angiography

    DEFF Research Database (Denmark)

    Havsteen, Inger; Christensen, Anders; Nielsen, Jens K

    2012-01-01

    BACKGROUND: Computed tomographic angiography (CTA) is widely available in emergency rooms to assess acute stroke patients. To standardize readings and educate new readers, we developed a 3-step e-learning tool based on the test-teach-retest methodology in 2 acute stroke scenarios: vascular...... occlusion and "spot sign" in acute intracerebral hemorrhage. We hypothesized that an e-learning program enhances reading skills in physicians of varying experience. METHODS: We developed an HTML-based program with a teaching segment and 2 matching test segments. Tests were taken before and after...... sign correctly 69% before versus 92% after teaching (P = .009) and reported a median self-perceived diagnostic certainty of 50% versus 75% (P = .030). Self-perceived diagnostic certainty revealed no significant increase for vascular occlusion. CONCLUSIONS: The e-learning program is a useful educational...

  6. Advanced Ultrasonic Tomograph of Children's Bones

    Science.gov (United States)

    Lasaygues, Philippe; Lefebvre, Jean-Pierre; Guillermin, Régine; Kaftandjian, Valérie; Berteau, Jean-Philippe; Pithioux, Martine; Petit, Philippe

    This study deals with the development of an experimental device for performing ultrasonic computed tomography (UCT) on bone in pediatric degrees. The children's bone tomographs obtained in this study, were based on the use of a multiplexed 2-D ring antenna (1 MHz and 3 MHz) designed for performing electronic and mechanical scanning. Although this approach is known to be a potentially valuable means of imaging objects with similar acoustical impedances, problems arise when quantitative images of more highly contrasted media such as bones are required. Various strategies and various mathematical procedures for modeling the wave propagation based on Born approximations have been developed at our laboratory, which are suitable for use with pediatric cases. Inversions of the experimental data obtained are presented.

  7. Tomographic PIV: principles and practice

    International Nuclear Information System (INIS)

    Scarano, F

    2013-01-01

    A survey is given of the major developments in three-dimensional velocity field measurements using the tomographic particle image velocimetry (PIV) technique. The appearance of tomo-PIV dates back seven years from the present review (Elsinga et al 2005a 6th Int. Symp. PIV (Pasadena, CA)) and this approach has rapidly spread as a versatile, robust and accurate technique to investigate three-dimensional flows (Arroyo and Hinsch 2008 Topics in Applied Physics vol 112 ed A Schröder and C E Willert (Berlin: Springer) pp 127–54) and turbulence physics in particular. A considerable number of applications have been achieved over a wide range of flow problems, which requires the current status and capabilities of tomographic PIV to be reviewed. The fundamental aspects of the technique are discussed beginning from hardware considerations for volume illumination, imaging systems, their configurations and system calibration. The data processing aspects are of uppermost importance: image pre-processing, 3D object reconstruction and particle motion analysis are presented with their fundamental aspects along with the most advanced approaches. Reconstruction and cross-correlation algorithms, attaining higher measurement precision, spatial resolution or higher computational efficiency, are also discussed. The exploitation of 3D and time-resolved (4D) tomographic PIV data includes the evaluation of flow field pressure on the basis of the flow governing equation. The discussion also covers a-posteriori error analysis techniques. The most relevant applications of tomo-PIV in fluid mechanics are surveyed, covering experiments in air and water flows. In measurements in flow regimes from low-speed to supersonic, most emphasis is given to the complex 3D organization of turbulent coherent structures. (topical review)

  8. Segmentation-DrivenTomographic Reconstruction

    DEFF Research Database (Denmark)

    Kongskov, Rasmus Dalgas

    such that the segmentation subsequently can be carried out by use of a simple segmentation method, for instance just a thresholding method. We tested the advantages of going from a two-stage reconstruction method to a one stage segmentation-driven reconstruction method for the phase contrast tomography reconstruction......The tomographic reconstruction problem is concerned with creating a model of the interior of an object from some measured data, typically projections of the object. After reconstructing an object it is often desired to segment it, either automatically or manually. For computed tomography (CT...

  9. Computer tomographic examinations in epilepsy

    International Nuclear Information System (INIS)

    De Villiers, J.F.K.

    1984-01-01

    Epileptic patients that was examined at the Universitas Hospital (Bloemfontein) by means of computerized tomography for the period July 1978 - December 1980, are divided into two groups: a) Patients with general epilepsy of convulsions - 507; b) Patients with vocal or partial epilepsy - 111. The method of examination and the results for both general and vocal epilepsy are discussed. A degenerative state was found in 35% of the positive computer tomographic examinations in general epilepsy and 22% of the positive examinations for vocal epilepsy. The purpose of the article was to explain the circumstances that can be expected when a epileptic patient is examined by means of computerized tomography

  10. Ovarian metastases: Computed tomographic appearances

    International Nuclear Information System (INIS)

    Megibow, A.J.; Hulnick, D.H.; Bosniak, M.A.; Balthazar, E.J.

    1985-01-01

    Computed tomographic scans of 34 patients with ovarian metastases were reviewed to assess the radiographic appearances and to correlate these with the primary neoplasms. Primary neoplasms were located in the colon (20 patients), breast (six), stomach (five), small bowel (one), bladder (one), and Wilms tumor of the kidney (one). The radiographic appearance of the metastatic lesions could be described as predominantly cystic (14 lesions), mixed (12 lesions), or solid (seven lesions). The cystic and mixed lesions tended to be larger in overall diameter than the solid. The metastases from gastric carcinoma appeared solid in four of five cases. The metastases from the other neoplasms had variable appearances simulating primary ovarian carcinoma

  11. Preclinical Evaluation of a Novel 177Lu- Radiopharmaceutical Based on Bombesin Structure for Prostate Tumor Diagnosis and Radionuclide Therapy

    International Nuclear Information System (INIS)

    Pujatti, P.B.; Santos, J.S.; Mengatti, J.; Araujo, E.B. de; Suzuki, M.F.; Soares, C.R.J.

    2009-01-01

    Prostate cancer is the most frequently diagnosed cancer in men in Brazil. Treatment options have varied, but once the tumor has metastasized, treatment become less effective and the cancer can progresses to a hormone refractory state characterized by high morbidity and mortality. Bombesin (BBN) receptors - in particular, the gastrin-releasing peptide (GRP) receptor - have been shown to be massively overexpressed in several human tumors types, including prostate cancer, and could be an alternative as target for its treatment by radionuclide therapy (RNT). A large number of BBN analogs had already been synthesized for this purpose and have shown to reduce tumor growth in mice. Nevertheless, most of the studied analogs exhibit high abdominal accumulation, especially in pancreas. This abdominal accumulation may represent a problem in clinical use of radiolabeled bombesin analogs probably due to serious side effects to patients. The goal of the present work was to radiolabel a novel peptide based on bombesin structure - DOTA-X-BBN(6-14), where X is a spacer of six aminoacids. - with lutetium-177, a β- emitter with optimal physical characteristics for RNT of small tumors and metastases, and to evaluate its in vitro and in vivo properties in Balb-c and Nude mice bearing prostate tumor (PC-3) xenografts. Preliminary studies were done to determine the best labeling conditions of BBNp6 and both ITLC and HPLC were applied to evaluate the radiochemical purity of the preparations. The stability of the radiolabeled peptide was assayed either after storing at 4 o C or incubation in human plasma at 37 deg. C. Biodistribution, pharmacokinetics, whole body and scintigraphic studies were performed in both healthy Balb-c and xenografted Nude mice, in order to characterize the biological properties of labeled peptide. In addition, the specificity of labeled bombesin derivative targeting to PC-3 tumor cells was analysed by in vivo competition assays. In vitro studies involved the

  12. Poster - 01: LabPET II Pixelated APD-Based PET Scanner for High-Resolution Preclinical Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lecomte, Roger; Arpin, Louis; Beaudoin, Jean-François; Bergeron, Mélanie; Bouchard, Jonathan; Bouziri, Haithem; Cadorette, Jules; Gaudin, Émilie; Jürgensen, Nadia; Koua, Konin Calliste; Trépanier, Pierre-Yves Lauzier; Leroux, Jean-Daniel; Loignon-Houle, Francis; Njejimana, Larissa; Paillé, Maxime; Paulin, Caroline; Pepin, Catherine; Pratte, Jean-François; Samson, Arnaud; Thibaudeau, Christian [Université de Sherbrooke, Université de Sherbrooke, CIMS/CRCHUS, Université de Sherbrooke, Université de Sherbrooke, Université de Sherbrooke, CIMS/CRCHUS, Université de Sherbrooke, Université de Sherbrooke, 3IT, Université de Sherbrooke, Novalgo Inc., Université de Sherbrooke, Université de Sherbrooke, CIMS/CRCHUS, 3IT, Université de Sherbrooke, Université de Sherbrooke, Université de Sherbrooke, Université de Sherbrooke, 3IT, Université de Sherbrooke (Canada); and others

    2016-08-15

    Purpose: LabPET II is a new generation APD-based PET scanner designed to achieve sub-mm spatial resolution using truly pixelated detectors and highly integrated parallel front-end processing electronics. Methods: The basic element uses a 4×8 array of 1.12×1.12 mm{sup 2} Lu{sub 1.9}Y{sub 0.1}SiO{sub 5}:Ce (LYSO) scintillator pixels with one-to-one coupling to a 4×8 pixelated monolithic APD array mounted on a ceramic carrier. Four detector arrays are mounted on a daughter board carrying two flip-chip, 64-channel, mixed-signal, application-specific integrated circuits (ASIC) on the backside interfacing to two detector arrays each. Fully parallel signal processing was implemented in silico by encoding time and energy information using a dual-threshold Time-over-Threshold (ToT) scheme. The self-contained 128-channel detector module was designed as a generic component for ultra-high resolution PET imaging of small to medium-size animals. Results: Energy and timing performance were optimized by carefully setting ToT thresholds to minimize the noise/slope ratio. ToT spectra clearly show resolved 511 keV photopeak and Compton edge with ToT resolution well below 10%. After correction for nonlinear ToT response, energy resolution is typically 24±2% FWHM. Coincidence time resolution between opposing 128-channel modules is below 4 ns FWHM. Initial imaging results demonstrate that 0.8 mm hot spots of a Derenzo phantom can be resolved. Conclusion: A new generation PET scanner featuring truly pixelated detectors was developed and shown to achieve a spatial resolution approaching the physical limit of PET. Future plans are to integrate a small-bore dedicated mouse version of the scanner within a PET/CT platform.

  13. Precision of quantum tomographic detection of radiation

    Energy Technology Data Exchange (ETDEWEB)

    D' Ariano, G.M. (Dipartimento di Fisica ' ' Alessandro Volta' ' , Via A. Bassi 6, I-27100, Pavia (Italy) Istituto Nazionale di Fisica Nucleare, Sezione di Pavia, Via A. Bassi 6, I-27100, Pavia (Italy)); Macchiavello, Chiara (Dipartimento di Fisica ' ' Alessandro Volta' ' , Via A. Bassi 6, I-27100, Pavia (Italy)); Paris, M.G.A. (Dipartimento di Fisica ' ' Alessandro Volta' ' , Via A. Bassi 6, I-27100, Pavia (Italy))

    1994-11-21

    Homodyne tomography provides an experimental technique for reconstructing the density matrix of the radiation field. Here we analyze the tomographic precision in recovering observables like the photon number, the quadrature, and the phase. We show that tomographic reconstruction, despite providing a complete characterization of the state of the field, is generally much less efficient than conventional detection techniques. ((orig.))

  14. Precision of quantum tomographic detection of radiation

    International Nuclear Information System (INIS)

    D'Ariano, G.M.; Macchiavello, Chiara; Paris, M.G.A.

    1994-01-01

    Homodyne tomography provides an experimental technique for reconstructing the density matrix of the radiation field. Here we analyze the tomographic precision in recovering observables like the photon number, the quadrature, and the phase. We show that tomographic reconstruction, despite providing a complete characterization of the state of the field, is generally much less efficient than conventional detection techniques. ((orig.))

  15. Estimation of spatial uncertainties of tomographic velocity models

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, M.; Du, Z.; Querendez, E. [SINTEF Petroleum Research, Trondheim (Norway)

    2012-12-15

    This research project aims to evaluate the possibility of assessing the spatial uncertainties in tomographic velocity model building in a quantitative way. The project is intended to serve as a test of whether accurate and specific uncertainty estimates (e.g., in meters) can be obtained. The project is based on Monte Carlo-type perturbations of the velocity model as obtained from the tomographic inversion guided by diagonal and off-diagonal elements of the resolution and the covariance matrices. The implementation and testing of this method was based on the SINTEF in-house stereotomography code, using small synthetic 2D data sets. To test the method the calculation and output of the covariance and resolution matrices was implemented, and software to perform the error estimation was created. The work included the creation of 2D synthetic data sets, the implementation and testing of the software to conduct the tests (output of the covariance and resolution matrices which are not implicitly provided by stereotomography), application to synthetic data sets, analysis of the test results, and creating the final report. The results show that this method can be used to estimate the spatial errors in tomographic images quantitatively. The results agree with' the known errors for our synthetic models. However, the method can only be applied to structures in the model, where the change of seismic velocity is larger than the predicted error of the velocity parameter amplitudes. In addition, the analysis is dependent on the tomographic method, e.g., regularization and parameterization. The conducted tests were very successful and we believe that this method could be developed further to be applied to third party tomographic images.

  16. Copper-64 Dichloride as Theranostic Agent for Glioblastoma Multiforme: A Preclinical Study

    Directory of Open Access Journals (Sweden)

    Cristina Ferrari

    2015-01-01

    Full Text Available Glioblastoma multiforme (GBM is the most common primary malignant brain tumor in adults with a median survival time less than one year. To date, there are only a limited number of effective agents available for GBM therapy and this does not seem to add much survival advantage over the conventional approach based on surgery and radiotherapy. Therefore, the development of novel therapeutic approaches to GBM is essential and those based on radionuclide therapy could be of significant clinical impact. Experimental evidence has clearly demonstrated that cancer cells have a particularly high fractional content of copper inside the nucleus compared to normal cells. This behavior can be conveniently exploited both for diagnosis and for delivering therapeutic payloads (theranostic of the radionuclide copper-64 into the nucleus of cancerous cells by intravenous administration of its simplest chemical form as dichloride salt [64Cu]CuCl2. To evaluate the potential theranostic role of [64Cu]CuCl2 in GBM, the present work reports results from a preclinical study carried out in a xenografted GBM tumor mouse model. Biodistribution data of this new agent were collected using a small-animal PET tomograph. Subsequently, groups of tumor implanted nude mice were treated with [64Cu]CuCl2 to simulate single- and multiple-dose therapy protocols, and results were analyzed to estimate therapeutic efficacy.

  17. NCI Pediatric Preclinical Testing Consortium

    Science.gov (United States)

    NCI has awarded grants to five research teams to participate in its Pediatric Preclinical Testing Consortium, which is intended to help to prioritize which agents to pursue in pediatric clinical trials.

  18. X-ray tomographic apparatus

    International Nuclear Information System (INIS)

    Walters, R.G.

    1982-01-01

    An x-ray tomographic system consists of a radiation source such as gamma or x radiation which produces a fan-shaped beam. The fan is wide enough to encompass the patient circle. The system further includes means for rotating the radiation source about the patient for less than a full rotation, and detectors for detecting the radiation at positions that surround the patient by 180 0 plus the angle of the fan beam plus the angle between adjacent fan detectors. Attenuation data from the detectors is sorted into detector fans of attenuation data, then processed. The convolved data is back-projected into an image memory and displayed on a video monitor

  19. Preparation and tomographic reconstruction of an arbitrary single-photon path qubit

    International Nuclear Information System (INIS)

    Baek, So-Young; Kim, Yoon-Ho

    2011-01-01

    We report methods for preparation and tomographic reconstruction of an arbitrary single-photon path qubit. The arbitrary single-photon path qubit is prepared losslessly by passing the heralded single-photon state from spontaneous parametric down-conversion through variable beam splitter. Quantum state tomography of the single-photon path qubit is implemented by introducing path-projection measurements based on the first-order single-photon quantum interference. Using the state preparation and path-projection measurements methods for the single-photon path qubit, we demonstrate preparation and complete tomographic reconstruction of the single-photon path qubit with arbitrary purity. -- Highlights: → We report methods for preparation and tomographic reconstruction of an arbitrary single-photon path qubit. → We implement path-projection measurements based on the first-order single-photon quantum interference. → We demonstrate preparation and complete tomographic reconstruction of the single-photon path qubit with arbitrary purity.

  20. Visual servoing in medical robotics: a survey. Part II: tomographic imaging modalities--techniques and applications.

    Science.gov (United States)

    Azizian, Mahdi; Najmaei, Nima; Khoshnam, Mahta; Patel, Rajni

    2015-03-01

    Intraoperative application of tomographic imaging techniques provides a means of visual servoing for objects beneath the surface of organs. The focus of this survey is on therapeutic and diagnostic medical applications where tomographic imaging is used in visual servoing. To this end, a comprehensive search of the electronic databases was completed for the period 2000-2013. Existing techniques and products are categorized and studied, based on the imaging modality and their medical applications. This part complements Part I of the survey, which covers visual servoing techniques using endoscopic imaging and direct vision. The main challenges in using visual servoing based on tomographic images have been identified. 'Supervised automation of medical robotics' is found to be a major trend in this field and ultrasound is the most commonly used tomographic modality for visual servoing. Copyright © 2014 John Wiley & Sons, Ltd.

  1. Tomographic anthropomorphic models. Pt. 1

    International Nuclear Information System (INIS)

    Veit, R.; Zankl, M.; Petoussi, N.; Mannweiler, E.; Drexler, G.; Williams, G.

    1989-01-01

    The first generation of heterogenoeous anthropomorphic mathematical models to be used in dose calculations was the MIRD-5 adult phantom, followed by the pediatric MIRD-type phantoms and by the GSF sex-specific phantoms ADAM and EVA. A new generation of realistic anthropomorphic models is now introduced. The organs and tissues of these models consist of a well defined number of volume elements (voxels), derived from computer tomographic (CT) data; consequently, these models were named voxel or tomographic models. So far two voxel models of real patients are available: one of an 8 week old baby and of a 7 year old child. For simplicity, the model of the baby will be referred to as BABY and that of the child as CHILD. In chapter 1 a brief literature review is given on the existing mathematical models and their applications. The reasons that lead to the construction of the new CT models is discussed. In chapter 2 the technique is described which allows to convert any physical object into computer files to be used for dose calculations. The technique which produces three dimensional reconstructions of high resolution is discussed. In chapter 3 the main characteristics of the models of the baby and child are given. Tables of organ masses and volumes are presented together with three dimensional images of some organs and tissues. A special mention is given to the assessment of bone marrow distribution. Chapter 4 gives a short description of the Monte Carlo code used in conjunction with the models to calculate organ and tissue doses resulting from photon exposures. Some technical details concerning the computer files which describe the models are also given. (orig./HP)

  2. Compact Positron Tomograph for Prostate Imaging

    National Research Council Canada - National Science Library

    Huber, Jennifer

    2004-01-01

    The goal of this project is to construct a functioning compact positron tomograph, whose geometry is optimized for detecting prostate tumors with molecular tracers such as 11Ccholine (carbon-11 choline...

  3. Compact Positron Tomograph for Prostate Imaging

    National Research Council Canada - National Science Library

    Huber, Jennifer S

    2005-01-01

    The goal of this project is to construct a functioning compact positron tomograph, whose geometry is optimized for detecting prostate tumors with molecular tracers such as 11Ccholine (carbon-11 choline...

  4. Computed tomographic findings of intracranial gliosis

    International Nuclear Information System (INIS)

    Weisberg, L.

    1981-01-01

    The clinical and computed tomographic (CT) findings in eight patients with pathological evidence of cerebral gliosis are analyzed. CT findings do not permit differentiation of gliosis from other neoplastic and non-neoplastic conditions. (orig.)

  5. Precision tomographic analysis of reactor fuels

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Deok; Lee, Chang Hee; Kim, Jong Soo; Jeong, Jwong Hwan; Nam, Ki Yong

    2001-03-01

    For the tomographical assay, search of current status, analysis of neutron beam characteristics, MCNP code simulation, sim-fuel fabrication, neutron experiment for sim-fuel, multiaxes operation system design were done. In sensitivity simulation, the reconstruction results showed the good agreement. Also, the scoping test at ANL was very helpful for actual assay. Therefore, the results are applied for HANARO tomographical system setup and consecutive next research.

  6. Precision tomographic analysis of reactor fuels

    International Nuclear Information System (INIS)

    Lee, Yong Deok; Lee, Chang Hee; Kim, Jong Soo; Jeong, Jwong Hwan; Nam, Ki Yong

    2001-03-01

    For the tomographical assay, search of current status, analysis of neutron beam characteristics, MCNP code simulation, sim-fuel fabrication, neutron experiment for sim-fuel, multiaxes operation system design were done. In sensitivity simulation, the reconstruction results showed the good agreement. Also, the scoping test at ANL was very helpful for actual assay. Therefore, the results are applied for HANARO tomographical system setup and consecutive next research

  7. Computed-tomographic determination of mineral content of bones

    International Nuclear Information System (INIS)

    Delov, I.; Tabakov, S.

    1988-01-01

    The problem of precise computed-tomographic densitometry of the mineral content of bones is pointed out. A method is proposed including the use of standard density and observance of definite radiation, scanning and image estimation parameters. A good correlation of the results obtained for the mineral content of the lumbar vertebrae with literature data are reported. A method is also described for determining the mineral content of tubular bones based on densiprofile check-up of the computed-tomographic density. The procedure takes 10-15 minutes and includes 1 or 2 scans. It might therefore gain wide acceptance for the diagnosis and tracing of osteoporosis and other osteopathies associated with distrorted calcium metabolism

  8. A tomograph VMEbus parallel processing data acquisition system

    International Nuclear Information System (INIS)

    Atkins, M.S.; Wilkinson, N.A.; Rogers, J.G.

    1988-11-01

    This paper describes a VME based data acquisition system suitable for the development of Positron Volume Imaging tomographs which use 3-D data for improved image resolution over slice-oriented tomographs. The data acquisition must be flexible enough to accommodate several 3-D reconstruction algorithms; hence, a software-based system is most suitable. Furthermore, because of the increased dimensions and resolution of volume imaging tomographs, the raw data event rate is greater than that of slice-oriented machines. These dual requirements are met by our data acquisition systems. Flexibility is achieved through an array of processors connected over a VMEbus, operating asynchronously and in parallel. High raw data throughput is achieved using a dedicated high speed data transfer device available for the VMEbus. The device can attain a raw data rate of 2.5 million coincidence events per second for raw events per second for raw events which are 64 bits wide. Real-time data acquisition and pre-processing requirements can be met by about forty 20 MHz Motorola 68020/68881 processors

  9. Preclinical models in radiation oncology

    Directory of Open Access Journals (Sweden)

    Kahn Jenna

    2012-12-01

    Full Text Available Abstract As the incidence of cancer continues to rise, the use of radiotherapy has emerged as a leading treatment modality. Preclinical models in radiation oncology are essential tools for cancer research and therapeutics. Various model systems have been used to test radiation therapy, including in vitro cell culture assays as well as in vivo ectopic and orthotopic xenograft models. This review aims to describe such models, their advantages and disadvantages, particularly as they have been employed in the discovery of molecular targets for tumor radiosensitization. Ultimately, any model system must be judged by its utility in developing more effective cancer therapies, which is in turn dependent on its ability to simulate the biology of tumors as they exist in situ. Although every model has its limitations, each has played a significant role in preclinical testing. Continued advances in preclinical models will allow for the identification and application of targets for radiation in the clinic.

  10. Metabolomics of Therapy Response in Preclinical Glioblastoma: A Multi-Slice MRSI-Based Volumetric Analysis for Noninvasive Assessment of Temozolomide Treatment

    Science.gov (United States)

    Arias-Ramos, Nuria; Ferrer-Font, Laura; Lope-Piedrafita, Silvia; Mocioiu, Victor; Julià-Sapé, Margarida; Pumarola, Martí; Arús, Carles; Candiota, Ana Paula

    2017-01-01

    Glioblastoma (GBM) is the most common aggressive primary brain tumor in adults, with a short survival time even after aggressive therapy. Non-invasive surrogate biomarkers of therapy response may be relevant for improving patient survival. Previous work produced such biomarkers in preclinical GBM using semi-supervised source extraction and single-slice Magnetic Resonance Spectroscopic Imaging (MRSI). Nevertheless, GBMs are heterogeneous and single-slice studies could prevent obtaining relevant information. The purpose of this work was to evaluate whether a multi-slice MRSI approach, acquiring consecutive grids across the tumor, is feasible for preclinical models and may produce additional insight into therapy response. Nosological images were analyzed pixel-by-pixel and a relative responding volume, the Tumor Responding Index (TRI), was defined to quantify response. Heterogeneous response levels were observed and treated animals were ascribed to three arbitrary predefined groups: high response (HR, n = 2), TRI = 68.2 ± 2.8%, intermediate response (IR, n = 6), TRI = 41.1 ± 4.2% and low response (LR, n = 2), TRI = 13.4 ± 14.3%, producing therapy response categorization which had not been fully registered in single-slice studies. Results agreed with the multi-slice approach being feasible and producing an inverse correlation between TRI and Ki67 immunostaining. Additionally, ca. 7-day oscillations of TRI were observed, suggesting that host immune system activation in response to treatment could contribute to the responding patterns detected. PMID:28524099

  11. Metabolomics of Therapy Response in Preclinical Glioblastoma: A Multi-Slice MRSI-Based Volumetric Analysis for Noninvasive Assessment of Temozolomide Treatment

    Directory of Open Access Journals (Sweden)

    Nuria Arias-Ramos

    2017-05-01

    Full Text Available Glioblastoma (GBM is the most common aggressive primary brain tumor in adults, with a short survival time even after aggressive therapy. Non-invasive surrogate biomarkers of therapy response may be relevant for improving patient survival. Previous work produced such biomarkers in preclinical GBM using semi-supervised source extraction and single-slice Magnetic Resonance Spectroscopic Imaging (MRSI. Nevertheless, GBMs are heterogeneous and single-slice studies could prevent obtaining relevant information. The purpose of this work was to evaluate whether a multi-slice MRSI approach, acquiring consecutive grids across the tumor, is feasible for preclinical models and may produce additional insight into therapy response. Nosological images were analyzed pixel-by-pixel and a relative responding volume, the Tumor Responding Index (TRI, was defined to quantify response. Heterogeneous response levels were observed and treated animals were ascribed to three arbitrary predefined groups: high response (HR, n = 2, TRI = 68.2 ± 2.8%, intermediate response (IR, n = 6, TRI = 41.1 ± 4.2% and low response (LR, n = 2, TRI = 13.4 ± 14.3%, producing therapy response categorization which had not been fully registered in single-slice studies. Results agreed with the multi-slice approach being feasible and producing an inverse correlation between TRI and Ki67 immunostaining. Additionally, ca. 7-day oscillations of TRI were observed, suggesting that host immune system activation in response to treatment could contribute to the responding patterns detected.

  12. Cone Beam Computed Tomographic imaging in orthodontics.

    Science.gov (United States)

    Scarfe, W C; Azevedo, B; Toghyani, S; Farman, A G

    2017-03-01

    Over the last 15 years, cone beam computed tomographic (CBCT) imaging has emerged as an important supplemental radiographic technique for orthodontic diagnosis and treatment planning, especially in situations which require an understanding of the complex anatomic relationships and surrounding structures of the maxillofacial skeleton. CBCT imaging provides unique features and advantages to enhance orthodontic practice over conventional extraoral radiographic imaging. While it is the responsibility of each practitioner to make a decision, in tandem with the patient/family, consensus-derived, evidence-based clinical guidelines are available to assist the clinician in the decision-making process. Specific recommendations provide selection guidance based on variables such as phase of treatment, clinically-assessed treatment difficulty, the presence of dental and/or skeletal modifying conditions, and pathology. CBCT imaging in orthodontics should always be considered wisely as children have conservatively, on average, a three to five times greater radiation risk compared with adults for the same exposure. The purpose of this paper is to provide an understanding of the operation of CBCT equipment as it relates to image quality and dose, highlight the benefits of the technique in orthodontic practice, and provide guidance on appropriate clinical use with respect to radiation dose and relative risk, particularly for the paediatric patient. © 2017 Australian Dental Association.

  13. Preclinical electrogastrography in experimental pigs

    Science.gov (United States)

    Květina, Jaroslav; Varayil, Jithinraj Edakkanambeth; Ali, Shahzad Marghoob; Kuneš, Martin; Bureš, Jan; Tachecí, Ilja; Rejchrt, Stanislav; Kopáčová, Marcela

    2010-01-01

    Surface electrogastrography (EGG) is a non-invasive means of recording gastric myoelectric activity or slow waves from cutaneous leads placed over the stomach. This paper provides a comprehensive review of preclinical EGG. Our group recently set up and worked out the methods for EGG in experimental pigs. We gained our initial experience in the use of EGG in assessment of porcine gastric myoelectric activity after volume challenge and after intragastric administration of itopride and erythromycin. The mean dominant frequency in pigs is comparable with that found in humans. EGG in experimental pigs is feasible. Experimental EGG is an important basis for further preclinical projects in pharmacology and toxicology. PMID:21217873

  14. Computed Tomographic Perfusion Improves Diagnostic Power of Coronary Computed Tomographic Angiography in Women

    DEFF Research Database (Denmark)

    Penagaluri, Ashritha; Higgins, Angela Y.; Vavere, Andrea L

    2016-01-01

    laboratories. Prevalence of flow-limiting CAD defined by invasive coronary angiography equal to 50% or greater with an associated single-photon emission computed tomography myocardial perfusion imaging defect was 45% (114/252) and 23% (30/129) in males and females, respectively. Patient-based diagnostic......Background-Coronary computed tomographic angiography (CTA) and myocardial perfusion imaging (CTP) is a validated approach for detection and exclusion of flow-limiting coronary artery disease (CAD), but little data are available on gender-specific performance of these modalities. In this study, we...... aimed to evaluate the diagnostic accuracy of combined coronary CTA and CTP in detecting flow-limiting CAD in women compared with men.  Methods and Results-Three hundred and eighty-one patients who underwent both CTA-CTP and single-photon emission computed tomography myocardial perfusion imaging...

  15. Three dimensional reconstruction of tomographic images of the retina

    International Nuclear Information System (INIS)

    Glittenberg, C.; Zeiler, F.; Falkner, C.; Binder, S.; Povazay, B.; Hermann, B.; Drexler, W.

    2007-01-01

    The development of a new display system for the three-dimensional visualization of tomographic images in ophthalmology. Specifically, a system that can use stacks of B-mode scans from an ultrahigh resolution optical tomography examination to vividly display retinal specimens as three-dimensional objects. Several subroutines were programmed in the rendering and raytracing program Cinema 4D XL 9.102 Studio Bundle (Maxon Computer Inc., Friedrichsburg, Germany), which could process stacks of tomographic scans into three-dimensional objects. Ultrahigh resolution optical coherence tomography examinations were performed on patients with various retinal pathologies and post processed with the subroutines that had been designed. All ultrahigh resolution optical coherence tomographies were performed with a titanium: sapphire based ultra broad bandwidth (160 nm) femtosecond laser system (INTEGRAL, Femtolasers Productions GmbH. Vienna Austria) with an axial resolution of 3 μm. A new three dimensional display system for tomographic images in ophthalmology was developed, which allows a highly vivid display of physiological and pathological structures of the retina. The system also distinguishes itself through its high interactivity and adaptability. This new display system allows the visualization of physiological and pathological structures of the retina in a new way, which will give us new insight into their morphology and development. (author) [de

  16. Industrial dynamic tomographic reconstruction; Reconstrucao tomografica dinamica industrial

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Eric Ferreira de

    2016-07-01

    The state of the art methods applied to industrial processes is currently based on the principles of classical tomographic reconstructions developed for tomographic patterns of static distributions, or is limited to cases of low variability of the density distribution function of the tomographed object. Noise and motion artifacts are the main problems caused by a mismatch in the data from views acquired in different instants. All of these add to the known fact that using a limited amount of data can result in the presence of noise, artifacts and some inconsistencies with the distribution under study. One of the objectives of the present work is to discuss the difficulties that arise from implementing reconstruction algorithms in dynamic tomography that were originally developed for static distributions. Another objective is to propose solutions that aim at reducing a temporal type of information loss caused by employing regular acquisition systems to dynamic processes. With respect to dynamic image reconstruction it was conducted a comparison between different static reconstruction methods, like MART and FBP, when used for dynamic scenarios. This comparison was based on a MCNPx simulation as well as an analytical setup of an aluminum cylinder that moves along the section of a riser during the process of acquisition, and also based on cross section images from CFD techniques. As for the adaptation of current tomographic acquisition systems for dynamic processes, this work established a sequence of tomographic views in a just-in-time fashion for visualization purposes, a form of visually disposing density information as soon as it becomes amenable to image reconstruction. A third contribution was to take advantage of the triple color channel necessary to display colored images in most displays, so that, by appropriately scaling the acquired values of each view in the linear system of the reconstruction, it was possible to imprint a temporal trace into the regularly

  17. Plasminogen-based capture combined with amplification technology for the detection of PrP(TSE in the pre-clinical phase of infection.

    Directory of Open Access Journals (Sweden)

    Christiane Segarra

    Full Text Available BACKGROUND: Variant Creutzfeldt-Jakob disease (vCJD is a neurodegenerative infectious disorder, characterized by a prominent accumulation of pathological isoforms of the prion protein (PrP(TSE in the brain and lymphoid tissues. Since the publication in the United Kingdom of four apparent vCJD cases following transfusion of red blood cells and one apparent case following treatment with factor VIII, the presence of vCJD infectivity in the blood seems highly probable. For effective blood testing of vCJD individuals in the preclinical or clinical phase of infection, it is considered necessary that assays detect PrP(TSE concentrations in the femtomolar range. METHODOLOGY/PRINCIPAL FINDINGS: We have developed a three-step assay that firstly captures PrP(TSE from infected blood using a plasminogen-coated magnetic-nanobead method prior to its serial amplification via protein misfolding cyclic amplification (PMCA and specific PrP(TSE detection by western blot. We achieved a PrP(TSE capture yield of 95% from scrapie-infected material. We demonstrated the possibility of detecting PrP(TSE in white blood cells, in buffy coat and in plasma isolated from the blood of scrapie-infected sheep collected at the pre-clinical stage of the disease. The test also allowed the detection of PrP(TSE in human plasma spiked with a 10(-8 dilution of vCJD-infected brain homogenate corresponding to the level of sensitivity (femtogram required for the detection of the PrP(TSE in asymptomatic carriers. The 100% specificity of the test was revealed using a blinded panel comprising 96 human plasma samples. CONCLUSION/SIGNIFICANCE: We have developed a sensitive and specific amplification assay allowing the detection of PrP(TSE in the plasma and buffy coat fractions of blood collected at the pre-clinical phase of the disease. This assay represents a good candidate as a confirmatory assay for the presence of PrP(TSE in blood of patients displaying positivity in large scale screening

  18. Implementation of 3D tomographic visualisation through planar ICT data from experimental gamma-ray tomographic system

    International Nuclear Information System (INIS)

    Umesh Kumar; Singh, Gursharan; Ravindran, V.R.

    2001-01-01

    Industrial Computed Tomography (ICT) is one of the latest methods of non-destructive testing and examination. Different prototypes of Computed Industrial Tomographic Imaging System (CITIS) have been developed and experimental data have been generated in Isotope Applications Division. The experimental gamma-rays based tomographic imaging system comprises of beam generator containing approx. 220 GBq (6 Curies) of 137 Cs, a single NaI(Tl) -PMT integral assembly in a thick shielding and associated electronics, stepper motor controlled mechanical manipulator, collimators and required software. CITIS data is normally acquired in one orientation of the sample. It may be sometimes required to view a tomographic plane in a different orientation. Also, 3D visualization may be required with the available 2D data set. All these can be achieved by processing the available data. We have customized some of the routines for this purpose provided IDL (Integrated Data Language) package to suit our requirements. The present paper discusses methodology adopted for this purpose with an illustrative example. (author)

  19. Computed tomographic findings of intracranial pyogenic abscess

    International Nuclear Information System (INIS)

    Kim, S. J.; Suh, J. H.; Park, C. Y.; Lee, K. C.; Chung, S. S.

    1982-01-01

    The early diagnosis and effective treatment of brain abscess pose a difficult clinical problem. With the advent of computed tomography, however, it appears that mortality due to intracranial abscess has significantly diminished. 54 cases of intracranial pyogenic abscess are presented. Etiologic factors and computed tomographic findings are analyzed and following result are obtained. 1. The common etiologic factors are otitis media, post operation, and head trauma, in order of frequency. 2. The most common initial computed tomographic findings of brain abscess is ring contrast enhancement with surrounding brain edema. 3. The most characteristic computed tomographic finding of ring contrast enhancement is smooth thin walled ring contrast enhancement. 4. Most of thick irregular ring contrast enhancement are abscess associated with cyanotic heart disease or poor operation. 5. The most common findings of epidural and subdural empyema is crescentic radiolucent area with thin wall contrast enhancement without surrounding brain edema in convexity of brain

  20. Arbitrary layer tomographic method and apparatus

    International Nuclear Information System (INIS)

    Kato, H.; Ishida, M.

    1984-01-01

    Many two-dimensional X-ray projection distribution images obtained by exposing an object to X-rays in various directions are once stored in positions different from one another in a stimulable phosphor sheet or respectively in many stimulable phosphor sheets. The stimulable phosphor sheet or sheets are then scanned with stimulating rays, and the light emitted thereby from the stimulable phosphor sheet or sheets is photoelectrically read out to obtain electric signals representing the X-ray projection distribution images. The electric signals are processed to obtain a tomographic image of an arbitrary tomographic layer of the object

  1. Three-dimensional bone-free computed tomographic angiography of aneurysms near the skull base using a new bone-removal application

    International Nuclear Information System (INIS)

    Tomura, Noriaki; Otani, Takahiro; Sakuma, Ikuo; Takahashi, Satoshi; Nishii, Toshiaki; Watarai, Jiro

    2009-01-01

    Bone elimination is needed for computed tomography angiography (CTA) because bone structures obscure aneurysms located at the skull base. The purpose of our study was to evaluate the efficacy of three-dimensional (3D)-CTA using an application for bone elimination. A total of 27 patients with 32 angiographically confirmed aneurysms near the skull base were investigated. The 3D maximum intensity projection (MIP) images were initially obtained using the application. Further postprocessing was performed to obtain the MIP and volume-rendered (VR) images. The quality of the initial MIP images by the application was analyzed. Visualization of aneurysms after further processing was also reviewed. The initial MIP images by the application showed almost bone-free images in 23 of the 27 patients. In 8 patients, the image of the internal carotid artery (ICA) was segmentally removed in the initial MIP images by the application. Further postprocessing was able to recover all loss of the ICA image in these eight patients. For visualizing aneurysms and their necks, VR images with the application were significantly superior to VR images without the application. The application for bone elimination allows fast, selective elimination of bony structures and can improve the interpretation of aneurysms near the skull base. (author)

  2. An analysis of peripheral small lung carcinomas less than 20 mm in diameter in non-adenocarcinomas and carcinoids. Computed tomographic findings based on radiologic-pathologic correlation

    International Nuclear Information System (INIS)

    Tanaka, Gaku; Yamada, Kouzo; Oshita, Fumihiro; Nomura, Ikuo; Noda, Kazumasa; Nakayama, Haruhiko; Mitsuda, Aki; Kameda, Youichi; Yamakido, Michio

    2000-01-01

    With the introduction of computed tomography (CT) for chest screening in recent years, more cases of resected peripheral small lung carcinomas have been reported. Many of these were adenocarcinomas. To focus on CT findings of peripheral non-adenocarcinoma nodules, we performed a retrospective analysis based on radiographic-pathologic correlations. We analyzed CT findings based on the pathology of peripheral small lung carcinomas, excluding the histological type of adenocarcinomas. We compared our findings with those observed in adenocarcinomas. We reviewed 28 peripheral small lung carcinoma nodules less than 20 mm in diameter, including 13 squamous cell carcinomas, 4 small cell carcinomas, 2 adeno- squamous cell carcinomas, 1 large cell carcinoma, and 8 carcinoids. The carcinomas were classified into two different patterns; non-adenocarcinomas excluding carcinoids, and carcinoids. Both were solid-density types on high-resolution CT (HR-CT) images. The HR-CT findings regarding the shape and number of notching, and the presence or absence of ground glass opacity (GGO) were different between non-adenocarcinomas excluding carcinoids and adenocarcinomas. On the other hand, the HR-CT findings regarding spiculations, GGO and pleural indentations, and the absence of bronchial compression were different between carcinoids and adenocarcinomas. The shape characteristics and internal and marginal analysis on HR-CT images can contribute to the differential diagnosis of the histological type of peripheral small lung carcinomas. (author)

  3. High affinity radiopharmaceuticals based upon lansoprazole for PET imaging of aggregated tau in Alzheimer's disease and progressive supranuclear palsy: synthesis, preclinical evaluation, and lead selection.

    Science.gov (United States)

    Fawaz, Maria V; Brooks, Allen F; Rodnick, Melissa E; Carpenter, Garrett M; Shao, Xia; Desmond, Timothy J; Sherman, Phillip; Quesada, Carole A; Hockley, Brian G; Kilbourn, Michael R; Albin, Roger L; Frey, Kirk A; Scott, Peter J H

    2014-08-20

    Abnormally aggregated tau is the hallmark pathology of tauopathy neurodegenerative disorders and is a target for development of both diagnostic tools and therapeutic strategies across the tauopathy disease spectrum. Development of carbon-11- or fluorine-18-labeled radiotracers with appropriate affinity and specificity for tau would allow noninvasive quantification of tau burden using positron emission tomography (PET) imaging. We have synthesized [(18)F]lansoprazole, [(11)C]N-methyl lansoprazole, and [(18)F]N-methyl lansoprazole and identified them as high affinity radiotracers for tau with low to subnanomolar binding affinities. Herein, we report radiosyntheses and extensive preclinical evaluation with the aim of selecting a lead radiotracer for translation into human PET imaging trials. We demonstrate that [(18)F]N-methyl lansoprazole, on account of the favorable half-life of fluorine-18 and its rapid brain entry in nonhuman primates, favorable kinetics, low white matter binding, and selectivity for binding to tau over amyloid, is the lead compound for progression into clinical trials.

  4. High Affinity Radiopharmaceuticals Based Upon Lansoprazole for PET Imaging of Aggregated Tau in Alzheimer’s Disease and Progressive Supranuclear Palsy: Synthesis, Preclinical Evaluation, and Lead Selection

    Science.gov (United States)

    2014-01-01

    Abnormally aggregated tau is the hallmark pathology of tauopathy neurodegenerative disorders and is a target for development of both diagnostic tools and therapeutic strategies across the tauopathy disease spectrum. Development of carbon-11- or fluorine-18-labeled radiotracers with appropriate affinity and specificity for tau would allow noninvasive quantification of tau burden using positron emission tomography (PET) imaging. We have synthesized [18F]lansoprazole, [11C]N-methyl lansoprazole, and [18F]N-methyl lansoprazole and identified them as high affinity radiotracers for tau with low to subnanomolar binding affinities. Herein, we report radiosyntheses and extensive preclinical evaluation with the aim of selecting a lead radiotracer for translation into human PET imaging trials. We demonstrate that [18F]N-methyl lansoprazole, on account of the favorable half-life of fluorine-18 and its rapid brain entry in nonhuman primates, favorable kinetics, low white matter binding, and selectivity for binding to tau over amyloid, is the lead compound for progression into clinical trials. PMID:24896980

  5. Computed tomographic appearances of sternocostoclavicular hyperostosis

    Energy Technology Data Exchange (ETDEWEB)

    Chigira, Masaki; Shimizu, Toru (Gunma Univ. (Japan). Dept. of Orthopaedic Surgery)

    1989-08-01

    Computed tomographical analysis of sternocostoclavicular hyperostosis was performed in 27 patients. In the earliest stage hyperostosis occurred around the cartilaginous portion of the first ribs. The sternoclavicular joint space was preserved even in the late stage III of the disorder. It is also suggested that perichondritis and periostitis play important roles in the etiology of this disorder. (orig./GDG).

  6. Computed tomographic appearances of sternocostoclavicular hyperostosis

    International Nuclear Information System (INIS)

    Chigira, Masaki; Shimizu, Toru

    1989-01-01

    Computed tomographical analysis of sternocostoclavicular hyperostosis was performed in 27 patients. In the earliest stage hyperostosis occurred around the cartilaginous portion of the first ribs. The sternoclavicular joint space was preserved even in the late stage III of the disorder. It is also suggested that perichondritis and periostitis play important roles in the etiology of this disorder. (orig./GDG)

  7. Photon emission tomographic apparatus and method

    International Nuclear Information System (INIS)

    Blum, A.S.

    1983-01-01

    Tomographic imaging system employs large area, collimated scintillation detector rotated around radiation emitting subject. Detector support rotates with an inner ring inside a stationary outer ring. Counterbalanced detector support arm is forced by spring action to cause collimator face to follow body contour as detector rotates around the body, thereby reducing collimator to subject distance to improve system resolution. Includes adjustable subject support system

  8. Case Report: Unusual computed tomographic features of ...

    African Journals Online (AJOL)

    A case report of a 57-year old woman who presented with signs and symptoms of intracranial mass. Computed tomographic (CT) and clinical features were unusual and suggestive of a parasaggital Meningioma. However an accurate diagnosis of a tuberculoma was made at surgery and histopathological examination.

  9. Quantum probability measures and tomographic probability densities

    NARCIS (Netherlands)

    Amosov, GG; Man'ko, [No Value

    2004-01-01

    Using a simple relation of the Dirac delta-function to generalized the theta-function, the relationship between the tomographic probability approach and the quantum probability measure approach with the description of quantum states is discussed. The quantum state tomogram expressed in terms of the

  10. The bar coil for NMR tomograph

    International Nuclear Information System (INIS)

    Bogorodzki, P.; Piatkowski, A.; Wasielewski, J.

    1995-01-01

    The bar coil (bi-planar) for the NMR tomograph, designed for medical diagnostics, has been described. The tests of coil shown that it generates good homogenous magnetic field in a big volume what results in improving of the signal-to-noise ratio

  11. Decomposition of time-resolved tomographic PIV

    NARCIS (Netherlands)

    Schmid, P.J.; Violato, D.; Scarano, F.

    2012-01-01

    An experimental study has been conducted on a transitional water jet at a Reynolds number of Re = 5,000. Flow fields have been obtained by means of time-resolved tomographic particle image velocimetry capturing all relevant spatial and temporal scales. The measured threedimensional flow fields have

  12. Connections model for tomographic images reconstruction

    International Nuclear Information System (INIS)

    Rodrigues, R.G.S.; Pela, C.A.; Roque, S.F. A.C.

    1998-01-01

    This paper shows an artificial neural network with an adequately topology for tomographic image reconstruction. The associated error function is derived and the learning algorithm is make. The simulated results are presented and demonstrate the existence of a generalized solution for nets with linear activation function. (Author)

  13. Design and construction of the gamma ray transmission tomographer g-TAC-02

    International Nuclear Information System (INIS)

    Pavon Hernandez, Noriel; Ravelo Sanchez, Alberto; Idel, Pedro; Macias Perez, Rafael; Garcia Trapaga, Cesar; Campos Montenegro, Augusto

    2000-01-01

    An equipment for gamma ray transmission tomographer was designed and constructed in the Higher Institute of Nuclear Sciences and Technology. It was the g-TAC-01, based on a nuclear instrumentation, a mechanic instrumentation, and the control of the system from a personal computer. This first version permitted to obtain the know how of the technology of construction of equipment for tomography. The present work describes the second version of the gamma ray transmission tomographer: the g-TAC-02, with very important upgrading in the control session. Now the control system is a microcontroller based, electronic control system, designed to work in multiples forms: manual, automatic and with the computer

  14. Tomographic analysis of CBF in cerebral infarction

    International Nuclear Information System (INIS)

    Segawa, Hiromu; Kimura, Kazumoto; Ueda, Yuichi; Nagai, Masakatsu; Yoshimasu, Norio.

    1983-01-01

    Cerebral perfusion was examined in various types of occlusive disease by computed tomographic CBF method. The method utilized has several advantages over conventional studies using isotope, providing high resolution images in a direct relation to CT anatomy. Ten representative cases were presented from 25 consective cases of occlusive disease studied by this method. The method included inhalation of 40 to 60% xenon with serial CT scanning for 25 min. K (build-up rate), lambda (partition coefficient) and CBF values were calculated from ΔHU for each pixel and ΔXe in expired air, based on Fick's principle, and displayed on CRT as K-, lambda- and CBF-map separately. CBF for gray matter of normal control was 82 +- 11 ml/100 gm/min and that for white matter was 24 +- 5 ml/100 gm/min. The ischemic threshold for gray matter appeared to be approximately 20 ml/100 gm/min, as blood flow in focus of complete infarction was below this level. Blood flow between 20 - 30 ml/ 100 gm/min caused some change on CT, such as localized atrophy, cortical thinning, loss of distinction between gray and white matter and decreased or increased density, which were considered to be compatible with pathological changes of laminar necrosis or gliosis with neuronal loss. In a case with occlusion of middle cerebral artery with subsequent recanalization, causing hemorrhagic infarct, hyperemia was observed in the infarcted cortex that was enhanced by iodine. Periventricular lucency observed in two cases, where blood flow was decreased below threshold, could be classified as ''watershed infarction'' mainly involving white matter. In moyamoya disease, blood flow in the anterior circulation was decreased near ischemic level, whereas that in basal ganglia and territory of posterior cerebral artery was fairly preserved, which was compatible with general angiographic finding of this disease. (author)

  15. Neuropsychiatric symptoms predict hypometabolism in preclinical Alzheimer disease.

    Science.gov (United States)

    Ng, Kok Pin; Pascoal, Tharick A; Mathotaarachchi, Sulantha; Chung, Chang-Oh; Benedet, Andréa L; Shin, Monica; Kang, Min Su; Li, Xiaofeng; Ba, Maowen; Kandiah, Nagaendran; Rosa-Neto, Pedro; Gauthier, Serge

    2017-05-09

    To identify regional brain metabolic dysfunctions associated with neuropsychiatric symptoms (NPS) in preclinical Alzheimer disease (AD). We stratified 115 cognitively normal individuals into preclinical AD (both amyloid and tau pathologies present), asymptomatic at risk for AD (either amyloid or tau pathology present), or healthy controls (no amyloid or tau pathology present) using [ 18 F]florbetapir PET and CSF phosphorylated tau biomarkers. Regression and voxel-based regression models evaluated the relationships between baseline NPS measured by the Neuropsychiatric Inventory (NPI) and baseline and 2-year change in metabolism measured by [ 18 F]fluorodeoxyglucose (FDG) PET. Individuals with preclinical AD with higher NPI scores had higher [ 18 F]FDG uptake in the posterior cingulate cortex (PCC), ventromedial prefrontal cortex, and right anterior insula at baseline. High NPI scores predicted subsequent hypometabolism in the PCC over 2 years only in individuals with preclinical AD. Sleep/nighttime behavior disorders and irritability and lability were the components of the NPI that drove this metabolic dysfunction. The magnitude of NPS in preclinical cases, driven by sleep behavior and irritability domains, is linked to transitory metabolic dysfunctions within limbic networks vulnerable to the AD process and predicts subsequent PCC hypometabolism. These findings support an emerging conceptual framework in which NPS constitute an early clinical manifestation of AD pathophysiology. Copyright © 2017 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Neurology.

  16. Imaging MOSS tomographic system for H-1NF

    International Nuclear Information System (INIS)

    Glass, F.; Howard, J.

    1999-01-01

    A tomographic diagnostic utilising the Modulated Optical Solid-State spectrometer (MOSS) is planned for the H-1NF stellarator at the ANU. It is designed to create two-dimensional temperature or velocity maps of a poloidal cross-section of the high temperature plasma of H-1NF. The introduction of the MOSS spectrometers has enabled the development of several diagnostics to be used on the H-1NF stellerator. The MOSS spectrometer allows calculations of the plasma temperature and bulk velocity based on a line-integrated measurement of light emitted from electronic transitions within the plasma. A tomographic system utilising a rotatable multi-view ring apparatus and spatial multiplexing through a MOSS spectrometer is currently being developed. The ring apparatus is placed inside the H-1NF vessel and encircles the plasma. Multiple line-of-sight views collect light through a poloidal cross-section of the plasma and the emitted light is coupled into large core optical fibres. The transmitted light, via the optical fibre bundle, is then imaged through a large aperture MOSS spectrometer and onto another optical fibre array. Each fibre is then fed into a photomultiplier tube for signal detection. Characterisation of the properties of the lithium niobate (LiNbO 3 ) crystal used for modulation in the MOSS spectrometer is being undertaken to account for ray divergence in the imaging system. Tomographic techniques enable the construction of a temperature or velocity map of the poloidal cross-section. Rotating the ring apparatus to a new viewing position for the next pulse of plasma should allow an accurate picture to be built up based on the reproducibility of the plasma pulses. It is expected that initial testing of the system will begin in May when H-1NF begins operations at 0.5 Telsa field strength

  17. Preclinical animal research on therapy dosimetry with dual isotopes

    International Nuclear Information System (INIS)

    Konijnenberg, Mark W.; Jong, Marion de

    2011-01-01

    Preclinical research into radionuclide therapies based on radiation dosimetry will enable the use of any LET-equivalent radionuclide. Radiation dose and dose rate have significant influence on dose effects in the tumour depending on its radiation sensitivity, possibilities for repair of sublethal damage, and repopulation during or after the therapy. Models for radiation response of preclinical tumour models after peptide receptor radionuclide therapy based on the linear quadratic model are presented. The accuracy of the radiation dose is very important for observation of dose-effects. Uncertainties in the radiation dose estimation arise from incomplete assay of the kinetics, low accuracy in volume measurements and absorbed dose S-values for stylized models instead of the actual animal geometry. Normal dose uncertainties in the order of 20% might easily make the difference between seeing a dose-effect or missing it altogether. This is true for the theoretical case of a homogeneous tumour type behaving in vivo in the same way as its cells do in vitro. Heterogeneity of tumours induces variations in clonogenic cell density, radiation sensitivity, repopulation capacity and repair kinetics. The influence of these aspects are analysed within the linear quadratic model for tumour response to radionuclide therapy. Preclinical tumour models tend to be less heterogenic than the clinical conditions they should represent. The results of various preclinical radionuclide therapy experiments for peptide receptor radionuclide therapy are compared to the outcome of theoretical models and the influence of increased heterogeneity is analysed when the results of preclinical research is transferred to the clinic. When the radiation dose and radiobiology of the tumour response is known well enough it may be possible to leave the current phenomenological approach in preclinical radionuclide therapy and start basing these experiments on radiation dose. Then the use of a gamma ray

  18. Preclinical animal research on therapy dosimetry with dual isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Konijnenberg, Mark W.; Jong, Marion de [Nuclear Medicine Department, Erasmus MC, Rotterdam (Netherlands)

    2011-06-15

    Preclinical research into radionuclide therapies based on radiation dosimetry will enable the use of any LET-equivalent radionuclide. Radiation dose and dose rate have significant influence on dose effects in the tumour depending on its radiation sensitivity, possibilities for repair of sublethal damage, and repopulation during or after the therapy. Models for radiation response of preclinical tumour models after peptide receptor radionuclide therapy based on the linear quadratic model are presented. The accuracy of the radiation dose is very important for observation of dose-effects. Uncertainties in the radiation dose estimation arise from incomplete assay of the kinetics, low accuracy in volume measurements and absorbed dose S-values for stylized models instead of the actual animal geometry. Normal dose uncertainties in the order of 20% might easily make the difference between seeing a dose-effect or missing it altogether. This is true for the theoretical case of a homogeneous tumour type behaving in vivo in the same way as its cells do in vitro. Heterogeneity of tumours induces variations in clonogenic cell density, radiation sensitivity, repopulation capacity and repair kinetics. The influence of these aspects are analysed within the linear quadratic model for tumour response to radionuclide therapy. Preclinical tumour models tend to be less heterogenic than the clinical conditions they should represent. The results of various preclinical radionuclide therapy experiments for peptide receptor radionuclide therapy are compared to the outcome of theoretical models and the influence of increased heterogeneity is analysed when the results of preclinical research is transferred to the clinic. When the radiation dose and radiobiology of the tumour response is known well enough it may be possible to leave the current phenomenological approach in preclinical radionuclide therapy and start basing these experiments on radiation dose. Then the use of a gamma ray

  19. Pressure spectra from single-snapshot tomographic PIV

    Science.gov (United States)

    Schneiders, Jan F. G.; Avallone, Francesco; Pröbsting, Stefan; Ragni, Daniele; Scarano, Fulvio

    2018-03-01

    The power spectral density and coherence of temporal pressure fluctuations are obtained from low-repetition-rate tomographic PIV measurements. This is achieved by extension of recent single-snapshot pressure evaluation techniques based upon the Taylor's hypothesis (TH) of frozen turbulence and vortex-in-cell (VIC) simulation. Finite time marching of the measured instantaneous velocity fields is performed using TH and VIC. Pressure is calculated from the resulting velocity time series. Because of the theoretical limitations, the finite time marching can be performed until the measured flow structures are convected out of the measurement volume. This provides a lower limit of resolvable frequency range. An upper limit is given by the spatial resolution of the measurements. Finite time-marching approaches are applied to low-repetition-rate tomographic PIV data of the flow past a straight trailing edge at 10 m/s. Reference results of the power spectral density and coherence are obtained from surface pressure transducers. In addition, the results are compared to state-of-the-art experimental data obtained from time-resolved tomographic PIV performed at 10 kHz. The time-resolved approach suffers from low spatial resolution and limited maximum acquisition frequency because of hardware limitations. Additionally, these approaches strongly depend upon the time kernel length chosen for pressure evaluation. On the other hand, the finite time-marching approaches make use of low-repetition-rate tomographic PIV measurements that offer higher spatial resolution. Consequently, increased accuracy of the power spectral density and coherence of pressure fluctuations are obtained in the high-frequency range, in comparison to the time-resolved measurements. The approaches based on TH and VIC are found to perform similarly in the high-frequency range. At lower frequencies, TH is found to underestimate coherence and intensity of the pressure fluctuations in comparison to time-resolved PIV

  20. Good Laboratory Practice Preclinical Safety Studies for GSK2696273 (MLV Vector-Based Ex Vivo Gene Therapy for Adenosine Deaminase Deficiency Severe Combined Immunodeficiency) in NSG Mice.

    Science.gov (United States)

    Carriglio, Nicola; Klapwijk, Jan; Hernandez, Raisa Jofra; Vezzoli, Michela; Chanut, Franck; Lowe, Rhiannon; Draghici, Elena; Nord, Melanie; Albertini, Paola; Cristofori, Patrizia; Richards, Jane; Staton, Hazel; Appleby, Jonathan; Aiuti, Alessandro; Sauer, Aisha V

    2017-03-01

    GSK2696273 (autologous CD34+ cells transduced with retroviral vector that encodes for the human adenosine deaminase [ADA] enzyme) is a gamma-retroviral ex vivo gene therapy of bone marrow-derived CD34+ cells for the treatment of adenosine deaminase deficiency severe combined immunodeficiency (ADA-SCID). ADA-SCID is a severe monogenic disease characterized by immunologic and nonimmunologic symptoms. Bone-marrow transplant from a matched related donor is the treatment of choice, but it is available for only a small proportion of patients. Ex vivo gene therapy of patient bone-marrow CD34+ cells is an alternative treatment. In order to prepare for a marketing authorization application in the European Union, preclinical safety studies in mice were requested by the European Medicines Agency (EMA). A pilot study and a main biodistribution study were performed according to Good Laboratory Practice (GLP) at the San Raffaele Telethon Institute for Gene Therapy test facility. In the main study, human umbilical cord blood (UCB)-derived CD34+ cells were transduced with gamma-retroviral vector used in the production of GSK2696273. Groups of 10 male and 10 female NOD-SCID gamma (NSG) mice were injected intravenously with a single dose of transduced- or mock-transduced UCB CD34+ cells, and they were observed for 4 months. Engraftment and multilineage differentiation of blood cells was observed in the majority of animals in both groups. There was no significant difference in the level of chimerism between the two groups. In the gene therapy group, vector was detectable in lymphohemopoietic and nonlymphohemopoietic tissues, consistent with the presence of gene-modified human hematopoietic donor cells. Given the absence of relevant safety concerns in the data, the nonclinical studies and the clinical experience with GSK2696273 supported a successful application for market authorization in the European Union for the treatment of ADA-SCID patients, for whom no suitable human leukocyte

  1. A Tomographic method based on genetic algorithms

    International Nuclear Information System (INIS)

    Turcanu, C.; Alecu, L.; Craciunescu, T.; Niculae, C.

    1997-01-01

    Computerized tomography being a non-destructive and non-evasive technique is frequently used in medical application to generate three dimensional images of objects. Genetic algorithms are efficient, domain independent for a large variety of problems. The proposed method produces good quality reconstructions even in case of very small number of projection angles. It requests no a priori knowledge about the solution and takes into account the statistical uncertainties. The main drawback of the method is the amount of computer memory and time needed. (author)

  2. DG TOMO: A new method for tomographic reconstruction

    International Nuclear Information System (INIS)

    Freitas, D. de; Feschet, F.; Cachin, F.; Geissler, B.; Bapt, A.; Karidioula, I.; Martin, C.; Kelly, A.; Mestas, D.; Gerard, Y.; Reveilles, J.P.; Maublant, J.

    2006-01-01

    Aim: FBP and OSEM are the most popular tomographic reconstruction methods in scintigraphy. FBP is a simple method but artifacts of reconstruction are generated which corrections induce degradation of the spatial resolution. OSEM takes account of statistical fluctuations but noise strongly increases after a certain number of iterations. We compare a new method of tomographic reconstruction based on discrete geometry (DG TOMO) to FBP and OSEM. Materials and methods: Acquisitions were performed on a three-head gamma-camera (Philips) with a NEMA Phantom containing six spheres of sizes from 10 to 37 mm inner diameter, filled with around 325 MBq/l of technetium-99 m. The spheres were positioned in water containing 3 MBq/l of technetium-99 m. Acquisitions were realized during a 180 o -rotation around the phantom by 25-s steps. DG TOMO has been developed in our laboratory in order to minimize the number of projections at acquisition. Two tomographic reconstructions utilizing 32 and 16 projections with FBP, OSEM and DG TOMO were performed and transverse slices were compared. Results: FBP with 32 projections detects only the activity in the three largest spheres (diameter ≥22 mm). With 16 projections, the star effect is predominant and the contrast of the third sphere is very low. OSEM with 32 projections provides a better image but the three smallest spheres (diameter ≤17 mm) are difficult to distinguish. With 16 projections, the three smaller spheres are not detectable. The results of DG TOMO are similar to OSEM. Conclusion: Since the parameters of DG TOMO can be further optimized, this method appears as a promising alternative for tomoscintigraphy reconstruction

  3. Do medical students generate sound arguments during small group discussions in problem-based learning?: an analysis of preclinical medical students' argumentation according to a framework of hypothetico-deductive reasoning.

    Science.gov (United States)

    Ju, Hyunjung; Choi, Ikseon; Yoon, Bo Young

    2017-06-01

    Hypothetico-deductive reasoning (HDR) is an essential learning activity and a learning outcome in problem-based learning (PBL). It is important for medical students to engage in the HDR process through argumentation during their small group discussions in PBL. This study aimed to analyze the quality of preclinical medical students' argumentation according to each phase of HDR in PBL. Participants were 15 first-year preclinical students divided into two small groups. A set of three 2-hour discussion sessions from each of the two groups during a 1-week-long PBL unit on the cardiovascular system was audio-recorded. The arguments constructed by the students were analyzed using a coding scheme, which included four types of argumentation (Type 0: incomplete, Type 1: claim only, Type 2: claim with data, and Type 3: claim with data and warrant). The mean frequency of each type of argumentation according to each HDR phase across the two small groups was calculated. During small group discussions, Type 1 arguments were generated most often (frequency=120.5, 43%), whereas the least common were Type 3 arguments (frequency=24.5, 8.7%) among the four types of arguments. The results of this study revealed that the students predominantly made claims without proper justifications; they often omitted data for supporting their claims or did not provide warrants to connect the claims and data. The findings suggest instructional interventions to enhance the quality of medical students' arguments in PBL, including promoting students' comprehension of the structure of argumentation for HDR processes and questioning.

  4. Self-masking noise subtraction (SMNS) in digital X-ray tomosynthesis for the improvement of tomographic image quality

    International Nuclear Information System (INIS)

    Oh, J.E.; Cho, H.S.; Choi, S.I.; Park, Y.O.; Lee, M.S.; Cho, H.M.; Yang, Y.J.; Je, U.K.; Woo, T.H.; Lee, H.K.

    2011-01-01

    In this paper, we proposed a simple and effective reconstruction algorithm, the so-called self-masking noise subtraction (SMNS), in digital X-ray tomosynthesis to reduce the tomographic blur that is inherent in the conventional tomosynthesis based upon the shift-and-add (SAA) method. Using the SAA and the SMNS algorithms, we investigated the influence of tomographic parameters such as tomographic angle (θ) and angle step (Δθ) on the image quality, measuring the signal-difference-to-noise ratio (SDNR). Our simulation results show that the proposed algorithm seems to be efficient in reducing the tomographic blur and, thus, improving image sharpness. We expect the simulation results to be useful for the optimal design of a digital X-ray tomosynthesis system for our ongoing application of nondestructive testing (NDT).

  5. NOD/scid IL-2Rgnull mice: a preclinical model system to evaluate human dendritic cell-based vaccine strategies in vivo

    Directory of Open Access Journals (Sweden)

    Spranger Stefani

    2012-02-01

    Full Text Available Abstract Background To date very few systems have been described for preclinical investigations of human cellular therapeutics in vivo. However, the ability to carry out comparisons of new cellular vaccines in vivo would be of substantial interest for design of clinical studies. Here we describe a humanized mouse model to assess the efficacy of various human dendritic cell (DC preparations. Two reconstitution regimes of NOD/scid IL2Rgnull (NSG mice with adult human peripheral blood mononuclear cells (PBMC were evaluated for engraftment using 4-week and 9-week schedules. This led to selection of a simple and rapid protocol for engraftment and vaccine evaluation that encompassed 4 weeks. Methods NSG recipients of human PBMC were engrafted over 14 days and then vaccinated twice with autologous DC via intravenous injection. Three DC vaccine formulations were compared that varied generation time in vitro (3 days versus 7 days and signals for maturation (with or without Toll-like receptor (TLR3 and TLR7/8 agonists using MART-1 as a surrogate antigen, by electroporating mature DC with in vitro transcribed RNA encoding full length protein. After two weekly vaccinations, the splenocyte populations containing human lymphocytes were recovered 7 days later and assessed for MART-1-specific immune responses using MHC-multimer-binding assays and functional assessment of specific killing of melanoma tumor cell lines. Results Human monocyte-derived DC generated in vitro in 3 days induced better MART-1-specific immune responses in the autologous donor T cells present in the humanized NSG mice. Moreover, consistent with our in vitro observations, vaccination using mature DC activated with TLR3 and TLR7/8 agonists resulted in enhanced immune responses in vivo. These findings led to a ranking of the DC vaccine effects in vivo that reflected the hierarchy previously found for these mature DC variations in vitro. Conclusions This humanized mouse model system enables

  6. Preclinical animal research on therapy dosimetry with dual isotopes

    NARCIS (Netherlands)

    M.W. Konijnenberg (Mark); M. de Jong (Marion)

    2011-01-01

    textabstractPreclinical research into radionuclide therapies based on radiation dosimetry will enable the use of any LET-equivalent radionuclide. Radiation dose and dose rate have significant influence on dose effects in the tumour depending on its radiation sensitivity, possibilities for repair of

  7. Subjective and Objective Evaluation of PBL Outcomes in Preclinical ...

    African Journals Online (AJOL)

    Subjective and Objective Evaluation of PBL Outcomes in Preclinical Medical Students. ... ABSTRACT: Problem based learning curriculum is widely recognized as a progressive, learner-centered, active learning approach and is currently used in the entire medical curriculum in over 10% of medical schools worldwide.

  8. Developing Potential Candidates of Preclinical Preeclampsia

    Directory of Open Access Journals (Sweden)

    Sandra Founds

    2015-11-01

    Full Text Available The potential for developing molecules of interest in preclinical preeclampsia from candidate genes that were discovered on gene expression microarray analysis has been challenged by limited access to additional first trimester trophoblast and decidual tissues. The question of whether these candidates encode secreted proteins that may be detected in maternal circulation early in pregnancy has been investigated using various proteomic methods. Pilot studies utilizing mass spectrometry based proteomic assays, along with enzyme linked immunosorbent assays (ELISAs, and Western immunoblotting in first trimester samples are reported. The novel targeted mass spectrometry methods led to robust multiple reaction monitoring assays. Despite detection of several candidates in early gestation, challenges persist. Future antibody-based studies may lead to a novel multiplex protein panel for screening or detection to prevent or mitigate preeclampsia.

  9. A fast multi-resolution approach to tomographic PIV

    Science.gov (United States)

    Discetti, Stefano; Astarita, Tommaso

    2012-03-01

    Tomographic particle image velocimetry (Tomo-PIV) is a recently developed three-component, three-dimensional anemometric non-intrusive measurement technique, based on an optical tomographic reconstruction applied to simultaneously recorded images of the distribution of light intensity scattered by seeding particles immersed into the flow. Nowadays, the reconstruction process is carried out mainly by iterative algebraic reconstruction techniques, well suited to handle the problem of limited number of views, but computationally intensive and memory demanding. The adoption of the multiplicative algebraic reconstruction technique (MART) has become more and more accepted. In the present work, a novel multi-resolution approach is proposed, relying on the adoption of a coarser grid in the first step of the reconstruction to obtain a fast estimation of a reliable and accurate first guess. A performance assessment, carried out on three-dimensional computer-generated distributions of particles, shows a substantial acceleration of the reconstruction process for all the tested seeding densities with respect to the standard method based on 5 MART iterations; a relevant reduction in the memory storage is also achieved. Furthermore, a slight accuracy improvement is noticed. A modified version, improved by a multiplicative line of sight estimation of the first guess on the compressed configuration, is also tested, exhibiting a further remarkable decrease in both memory storage and computational effort, mostly at the lowest tested seeding densities, while retaining the same performances in terms of accuracy.

  10. Present state and development of positron tomographs

    International Nuclear Information System (INIS)

    Allemand, R.; Gariod, R.; Laval, M.; Tournier, F.

    1979-01-01

    This document presents the main characteristics of positron tomographs and analyses the relative importance of the parameters to be taken into consideration in the design of a tomograph: on the one hand, the physical parameters linked to the measurement of the annihilation photons by time coincidence and, on the other, the geometrical and technological parameters of prime importance in minimizing the many spurious effects. The last part endeavours to show this sort of instrumentation has evolved. Using the results obtained in our laboratory by mathematical simulation, the expected advantages are presented on the picture quality of the time of flight measurement of annihilation photons. Where the physical aspects of this method are concerned, the advantage of using cesium fluoride as scintillator is demonstrated [fr

  11. The computed tomographic appearances of cherubism

    International Nuclear Information System (INIS)

    Bianchi, S.D.; Boccardi, A.; Mela, F.; Romagnoli, R.

    1987-01-01

    The computed tomographic (CT) aspects of six cases of cherubism are described. Through its optimal representation of the lesions, CT enabled certain characteristics of this disease to be substantiated, namely, limitation of the process to the bones of the jaw and primarily superficial development of the mandibular lesions, coupled with an unusual mandibular condylar impairment. Moreover, the composition of this series permitted investigation of the condition in its several stages of progression. (orig.)

  12. Tomographic scanning apparatus with ionization detector means

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification describes a tomographic scanning apparatus using a fan beam and digital output signal. Particular reference is made to the gas-pressurized ionization detector chamber, consisting of an array of side-by-side elongate ionization detection cells, the principal axis of each of the said cells being oriented along a radius extending towards the radiation source, and connection means for applying potentials across the cells for taking their output signals. (U.K.)

  13. A Penalization Approach for Tomographic Reconstruction of Binary Axially Symmetric Objects

    International Nuclear Information System (INIS)

    Abraham, R.; Bergounioux, M.; Trelat, E.

    2008-01-01

    We propose a variational method for tomographic reconstruction of blurred and noised binary images based on a penalization process of a minimization problem settled in the space of bounded variation functions. We prove existence and/or uniqueness results and derive a penalized optimality system. Numerical simulations are provided to demonstrate the relevance of the approach

  14. An original acquisition chain for the TOHR High Resolution Tomograph

    International Nuclear Information System (INIS)

    Pinot, Laurent

    1999-01-01

    The framework of this work is part of a new approach of emission tomography adapted to small animals. The principle of our tomographic system TOHR (French acronym for High Resolution Tomograph) is based on the use of large solid angle and high resolution focusing collimators each mounted in front of a detection module of high efficiency. With a first-generation acquisition chain we were able to characterize TOHR, however, to take fully advantage of the TOHR possibilities, a completely new acquisition scheme had to be designed. This system, being the main topic of this work, makes use of temporal information. The detection of a particle that entered the detector is translated into temporal logical signals. These signals pass into a time coding circuitry and the coded results are transferred in a digital processor. According to the initial terms of delivery, the developed acquisition chain steers the detection of events dependent on the deposited energy and time of arrival. The latter is done by coincidence measurements. All elements are mounted on a special board included into a PC unit and a dedicated program controls the whole system. First experiments showed up the interest of the new acquisition unit for other application in physics or medical imaging

  15. Perspective: Recommendations for benchmarking pre-clinical studies of nanomedicines

    Science.gov (United States)

    Dawidczyk, Charlene M.; Russell, Luisa M.; Searson, Peter C.

    2015-01-01

    Nanoparticle-based delivery systems provide new opportunities to overcome the limitations associated with traditional small molecule drug therapy for cancer, and to achieve both therapeutic and diagnostic functions in the same platform. Pre-clinical trials are generally designed to assess therapeutic potential and not to optimize the design of the delivery platform. Consequently, progress in developing design rules for cancer nanomedicines has been slow, hindering progress in the field. Despite the large number of pre-clinical trials, several factors restrict comparison and benchmarking of different platforms, including variability in experimental design, reporting of results, and the lack of quantitative data. To solve this problem, we review the variables involved in the design of pre-clinical trials and propose a protocol for benchmarking that we recommend be included in in vivo pre-clinical studies of drug delivery platforms for cancer therapy. This strategy will contribute to building the scientific knowledge base that enables development of design rules and accelerates the translation of new technologies. PMID:26249177

  16. Tomographic visualization of stress corrosion cracks in tubing

    International Nuclear Information System (INIS)

    Morris, R.A.; Kruger, R.P.; Wecksung, G.W.

    1979-06-01

    A feasibility study was conducted to determine the possibility of detecting and sizing cracks in reactor cooling water tubes using tomographic techniques. Due to time and financial constraints, only one tomographic reconstruction using the best technique available was made. The results indicate that tomographic reconstructions can, in fact, detect cracks in the tubing and might possibly be capable of measuring the depth of the cracks. Limits of detectability and sensitivity have not been determined but should be investigated in any future work

  17. Tomographic reconstruction of binary fields

    International Nuclear Information System (INIS)

    Roux, Stéphane; Leclerc, Hugo; Hild, François

    2012-01-01

    A novel algorithm is proposed for reconstructing binary images from their projection along a set of different orientations. Based on a nonlinear transformation of the projection data, classical back-projection procedures can be used iteratively to converge to the sought image. A multiscale implementation allows for a faster convergence. The algorithm is tested on images up to 1 Mb definition, and an error free reconstruction is achieved with a very limited number of projection data, saving a factor of about 100 on the number of projections required for classical reconstruction algorithms.

  18. A miniature electrical capacitance tomograph

    Science.gov (United States)

    York, T. A.; Phua, T. N.; Reichelt, L.; Pawlowski, A.; Kneer, R.

    2006-08-01

    The paper describes a miniature electrical capacitance tomography system. This is based on a custom CMOS silicon integrated circuit comprising eight channels of signal conditioning electronics to source drive signals and measure voltages. Electrodes are deposited around a hole that is fabricated, using ultrasonic drilling, through a ceramic substrate and has an average diameter of 0.75 mm. The custom chip is interfaced to a host computer via a bespoke data acquisition system based on a microcontroller, field programmable logic device and wide shift register. This provides fast capture of up to 750 frames of data prior to uploading to the host computer. Data capture rates of about 6000 frames per second have been achieved for the eight-electrode sensor. This rate could be increased but at the expense of signal to noise. Captured data are uploaded to a PC, via a RS232 interface, for off-line imaging. Initial tests are reported for the static case involving 200 µm diameter rods that are placed in the sensor and for the dynamic case using the dose from an inhaler.

  19. Ratios between effective doses for tomographic and mathematician models due to internal exposure of photons

    International Nuclear Information System (INIS)

    Lima, F.R.A.; Kramer, R.; Khoury, H.J.; Santos, A.M.; Loureiro, E.C.M.

    2005-01-01

    The development of new and sophisticated Monte Carlo codes and tomographic human phantoms or voxels motivated the International Commission on Radiological Protection (ICRP) to revise the traditional models of exposure, which have been used to calculate effective dose coefficients for organs and tissues based on mathematician phantoms known as MIRD5. This paper shows the results of calculations using tomographic phantoms MAX (Male Adult voXel) and FAX (Female Adult voXel), recently developed by the authors as well as with the phantoms ADAM and EVA, of specific genres, type MIRD5, coupled to the EGS4 Monte Carlo and MCNP4C codes, for internal exposure with photons of energies between 10 keV and 4 MeV to several organs sources. Effective Doses for both models, tomographic and mathematician, will be compared separately as a function of the Monte Carlo code replacement, of compositions of human tissues and the anatomy reproduced through tomographs. The results indicate that for photon internal exposure, the use of models of exposure based in voxel, increases the values of effective doses up to 70% for some organs sources considered in this study, when compared with the corresponding results obtained with phantoms of MIRD-5 type

  20. Preclinical Pharmacokinetic/Pharmacodynamic Modeling and Simulation in the Pharmaceutical Industry: An IQ Consortium Survey Examining the Current Landscape

    OpenAIRE

    Schuck, Edgar; Bohnert, Tonika; Chakravarty, Arijit; Damian-Iordache, Valeriu; Gibson, Christopher; Hsu, Cheng-Pang; Heimbach, Tycho; Krishnatry, Anu Shilpa; Liederer, Bianca M; Lin, Jing; Maurer, Tristan; Mettetal, Jerome T; Mudra, Daniel R; Nijsen, Marjoleen JMA; Raybon, Joseph

    2015-01-01

    The application of modeling and simulation techniques is increasingly common in preclinical stages of the drug discovery and development process. A survey focusing on preclinical pharmacokinetic/pharmacodynamics (PK/PD) analysis was conducted across pharmaceutical companies that are members of the International Consortium for Quality and Innovation in Pharmaceutical Development. Based on survey responses, ~68% of companies use preclinical PK/PD analysis in all therapeutic areas indicating its...

  1. Computed tomographic findings of traumatic intracranial lesions

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Seong Wook; Kim, Il Young; Lee, Byung Ho; Kim, Ki Jeoung; Yoon, Il Gyu [Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    1985-10-15

    Traumatic intracranial lesion has been one of the most frequent and serious problem in neurosurgical pathology. Computed tomography made it possible to get prompt diagnosis and surgical intervention of intracranial lesions by its safety, fastness and accuracy. Computed tomographic scan was carried out on 1309 cases at Soonchunhyang Chunan Hospital for 15 months from October 1983 to December 1984. We have reviewed the computed tomographic scans of 264 patients which showed traumatic intracranial lesion. The result were as follows: 1. Head trauma was the most frequent diagnosed disease using computed tomographic scans (57.8%) and among 264 cases the most frequent mode of injury was traffic accident (73.9%). 2. Skull fracture was accompanied in frequency of 69.7% and it was detected in CT in 38.6%: depression fracture was more easily detected in 81%. 3. Conutercoup lesion (9.5%) was usually accompanied with temporal and occipital fracture, and it appeared in lower incidence among pediatric group. 4. Intracranial lesions of all 264 cases were generalized cerebral swelling (24.6%), subdural hematoma (22.3%), epidural hematoma (20.8%), intracerebral hematoma (6.1%), and subarachnoid hemorrhage (3.0%). 5. The shape of hematoma was usually biconvex (92.7%) in acute epidural hematoma and cresentic (100%) in acute subdural hematoma, but the most chronic the case became, they showed planoconvex and bicconvex shapes. 6. Extra-axial hematoma was getting decreased in density as time gone by. 7. Hematoma density was not in direct proportion to serum hemoglobin level as single factor.

  2. Computed tomographic findings of traumatic intracranial lesions

    International Nuclear Information System (INIS)

    Jeong, Seong Wook; Kim, Il Young; Lee, Byung Ho; Kim, Ki Jeoung; Yoon, Il Gyu

    1985-01-01

    Traumatic intracranial lesion has been one of the most frequent and serious problem in neurosurgical pathology. Computed tomography made it possible to get prompt diagnosis and surgical intervention of intracranial lesions by its safety, fastness and accuracy. Computed tomographic scan was carried out on 1309 cases at Soonchunhyang Chunan Hospital for 15 months from October 1983 to December 1984. We have reviewed the computed tomographic scans of 264 patients which showed traumatic intracranial lesion. The result were as follows: 1. Head trauma was the most frequent diagnosed disease using computed tomographic scans (57.8%) and among 264 cases the most frequent mode of injury was traffic accident (73.9%). 2. Skull fracture was accompanied in frequency of 69.7% and it was detected in CT in 38.6%: depression fracture was more easily detected in 81%. 3. Conutercoup lesion (9.5%) was usually accompanied with temporal and occipital fracture, and it appeared in lower incidence among pediatric group. 4. Intracranial lesions of all 264 cases were generalized cerebral swelling (24.6%), subdural hematoma (22.3%), epidural hematoma (20.8%), intracerebral hematoma (6.1%), and subarachnoid hemorrhage (3.0%). 5. The shape of hematoma was usually biconvex (92.7%) in acute epidural hematoma and cresentic (100%) in acute subdural hematoma, but the most chronic the case became, they showed planoconvex and bicconvex shapes. 6. Extra-axial hematoma was getting decreased in density as time gone by. 7. Hematoma density was not in direct proportion to serum hemoglobin level as single factor

  3. Computer tomographic investigation of ancient Egyptian mummies

    International Nuclear Information System (INIS)

    Huebner, K.H.; Pahl, W.M.; Tuebingen Univ.

    1981-01-01

    Radiological and computer tomographic examinations of Egyptian mummies have been carried out at the Institute of Anthropology and Human Genetics from 1975 to 1978. These have demonstrated the value of CT in medical archaeology. It enables one to study the soft tissues, the skin (if bandaged), the muscles and any organs retained in situ for magical or religious reason. Measurements of attenuation values indicate the materials which were used for mummifying the skin and organs. Characteristic examples are described and the early results of these examinations are discussed. (orig.) [de

  4. Computer tomographic investigation of ancient Egyptian mummies

    Energy Technology Data Exchange (ETDEWEB)

    Huebner, K H; Pahl, W M

    1981-08-01

    Radiological and computer tomographic examinations of Egyptian mummies have been carried out at the Institute of Anthropology and Human Genetics from 1975 to 1978. These have demonstrated the value of CT in medical archaeology. It enables one to study the soft tissues, the skin (if bandaged), the muscles and any organs retained in situ for magical or religious reason. Measurements of attenuation values indicate the materials which were used for mummifying the skin and organs. Characteristic examples are described and the early results of these examinations are discussed.

  5. An intragastric trichobezoar: computerised tomographic appearance.

    Directory of Open Access Journals (Sweden)

    Morris B

    2000-04-01

    Full Text Available A 26-year-old lady presented with a history of abdominal pain and distension since two months. The ultrasound examination showed an epigastric mass, which was delineated as a filling defect in the stomach on barium studies. The computerised tomographic scan showed a gastric mass with pockets of air in it, without post-contrast enhancement. This case highlights the characteristic appearance on computerised tomography of a bezoar within the stomach, a feature that is not commonly described in medical literature.

  6. Computed tomographic study in children with microcephaly

    International Nuclear Information System (INIS)

    Ito, Masatoshi; Okuno, Takehiko; Mikawa, Haruki

    1989-01-01

    Computed tomographic (CT) brain scanning was performed on fifty-eight infants and children with microcephaly. CT scans were useful for detecting unsuspected brain lesions and for diagnosing underlying diseases. The head size did not correlate with the CT findings, the degree of mental retardation, or the existence of motor disturbance or epilepsy. On the other hand, the CT findings were correlated with the degree of mental retardation, and the existence of motor disturbance or epilepsy. CT scans were useful for determining the prognosis of the microcephaly. (author)

  7. 3D velocity measurements in a premixed flame by tomographic PIV

    International Nuclear Information System (INIS)

    Tokarev, M P; Sharaborin, D K; Lobasov, A S; Chikishev, L M; Dulin, V M; Markovich, D M

    2015-01-01

    Tomographic particle image velocimetry (PIV) has become a standard tool for 3D velocity measurements in non-reacting flows. However, the majority of the measurements in flows with combustion are limited to small resolved depth compared to the size of the field of view (typically 1 : 10). The limitations are associated with inhomogeneity of the volume illumination and the non-uniform flow seeding, the optical distortions and errors in the 3D calibration, and the unwanted flame luminosity. In the present work, the above constraints were overcome for the tomographic PIV experiment in a laminar axisymmetric premixed flame. The measurements were conducted for a 1 : 1 depth-to-size ratio using a system of eight CCD cameras and a 200 mJ pulsed laser. The results show that camera calibration based on the triangulation of the tracer particles in the non-reacting conditions provided reliable accuracy for the 3D image reconstruction in the flame. The modification of the tomographic reconstruction allowed a posteriori removal of unwanted bright objects, which were located outside of the region of interest but affected the reconstruction quality. This study reports on a novel experience for the instantaneous 3D velocimetry in laboratory-scale flames by using tomographic PIV. (paper)

  8. Experience of computed tomographic myelography and discography in cervical problem

    Energy Technology Data Exchange (ETDEWEB)

    Nakatani, Shigeru; Yamamoto, Masayuki; Uratsuji, Masaaki; Suzuki, Kunio; Matsui, Eigo [Hyogo Prefectural Awaji Hospital, Sumoto, Hyogo (Japan); Kurihara, Akira

    1983-06-01

    CTM (computed tomographic myelography) was performed on 15 cases of cervical lesions, and on 5 of them, CTD (computed tomographic discography) was also made. CTM revealed the intervertebral state, and in combination with CTD, providing more accurate information. The combined method of CTM and CTD was useful for soft disc herniation.

  9. Terahertz wave tomographic imaging with a Fresnel lens

    Institute of Scientific and Technical Information of China (English)

    S. Wang; X.-C. Zhang

    2003-01-01

    We demonstrate three-dimensional tomographic imaging using a Fresnel lens with broadband terahertz pulses. Objects at various locations along the beam propagation path are uniquely imaged on the same imaging plane using a Fresnel lens with different frequencies of the imaging beam. This procedure allows the reconstruction of an object's tomographic contrast image by assembling the frequency-dependent images.

  10. Integrated and Contextual Basic Science Instruction in Preclinical Education: Problem-Based Learning Experience Enriched with Brain/Mind Learning Principles

    Science.gov (United States)

    Gülpinar, Mehmet Ali; Isoglu-Alkaç, Ümmühan; Yegen, Berrak Çaglayan

    2015-01-01

    Recently, integrated and contextual learning models such as problem-based learning (PBL) and brain/mind learning (BML) have become prominent. The present study aimed to develop and evaluate a PBL program enriched with BML principles. In this study, participants were 295 first-year medical students. The study used both quantitative and qualitative…

  11. Preclinical models for obesity research

    Directory of Open Access Journals (Sweden)

    Perry Barrett

    2016-11-01

    Full Text Available A multi-dimensional strategy to tackle the global obesity epidemic requires an in-depth understanding of the mechanisms that underlie this complex condition. Much of the current mechanistic knowledge has arisen from preclinical research performed mostly, but not exclusively, in laboratory mouse and rat strains. These experimental models mimic certain aspects of the human condition and its root causes, particularly the over-consumption of calories and unbalanced diets. As with human obesity, obesity in rodents is the result of complex gene–environment interactions. Here, we review the traditional monogenic models of obesity, their contemporary optogenetic and chemogenetic successors, and the use of dietary manipulations and meal-feeding regimes to recapitulate the complexity of human obesity. We critically appraise the strengths and weaknesses of these different models to explore the underlying mechanisms, including the neural circuits that drive behaviours such as appetite control. We also discuss the use of these models for testing and screening anti-obesity drugs, beneficial bio-actives, and nutritional strategies, with the goal of ultimately translating these findings for the treatment of human obesity.

  12. Ethical Considerations of Preclinical Testing

    Directory of Open Access Journals (Sweden)

    Allen Goldenthal

    2015-12-01

    Full Text Available The numbers of animal tests being conducted are on a sharp incline.  Much of this increase is directly due to our ability to generate transgenic models and knock-outs, thereby increasing the validity of the animal model but not necessarily correlating directly with any translational medical benefits to the human counterpart.  In spite of our best efforts, there still exist species differences that prevent the application directly from animal to human, and in some examples having a completely different and adverse effect from that seen in the animal model. There are several ways in which we can improve the opportunity for a positive test outcome and at the same time reduce the animal usage which is associated with our current animal testing practices. The benefit of the 3R’s is that they encourage us not only to avoid wastage of life but that they require us to provide considerable foresight and extrapolated thought before directly engaging in the preclinical testing phase.

  13. Preclinical studies of dendrimer prodrugs.

    Science.gov (United States)

    Kojima, Chie

    2015-01-01

    Dendrimers are synthetic macromolecules with well-defined structures bearing a wide variety of functional groups on their periphery. These groups can be used to conjugate bioactive molecules such as drugs, ligands and imaging agents. Dendrimer prodrugs can be used to improve the water solubility and pharmacokinetic properties of the corresponding free drugs. This article summarizes preclinical studies pertaining to the use of drug-dendrimer conjugates as dendrimer prodrugs for the treatments of various diseases, including cancer and inflammatory diseases. A wide range of anticancer drugs have been conjugated to dendrimers via biodegradable linkers. The side effects of the parent drugs can be markedly reduced using dendrimer prodrugs, with some drugs showing improved efficacy. Anti-inflammatory agents have also been conjugated to dendrimers and used to treat a number of inflammatory diseases. Drug-dendrimer conjugates are preferable to drug-dendrimer complexes, where the use of degradable linkers is critical to the release of the drug. Polyethylene glycol and/or ligands can be added to a dendrimer prodrug, which is useful for the targeting of affected tissues. Imaging probes can also be incorporated into dendrimer prodrugs for the simultaneous delivery of therapeutic and diagnostic agents as 'theranostics.'

  14. Computerized tomographic in non-destructive testing

    International Nuclear Information System (INIS)

    Lopes, R.T.

    1988-01-01

    The process of computerized tomography has been developed for medical imaging purposes using tomographs with X-ray, and little attention has been given to others possibles applications of technique, because of its cost. As an alternative for the problem, we constructed a Tomographic System (STAC-1), using gamma-rays, for nonmedical applications. In this work we summarize the basic theory of reconstructing images using computerized tomography and we describe the considerations leading to the development of the experimental system. The method of reconstruction image implanted in the system is the filtered backprojection or convolution, with a digital filters system to carried on a pre-filtering in the projections. The experimental system is described, with details of control and the data processing. An alternative and a complementary system, using film as a detector is shown in preliminary form . This thesis discuss and shows the theorical and practical aspects, considered in the construction of the STAC-1, and also its limitations and apllications [pt

  15. Mesooptical microscope as a tomographical device

    International Nuclear Information System (INIS)

    Soroko, L.M.

    1989-01-01

    It is shown that there are at least four regions which are common for the mesooptical microscopes, on the one hand, and for the reconstructed tomography, on the other hand. The following characteristics of the mesooptical microscope show the tomographical properties: the structure of the output data concerning the orientation and the position in space of the straight-line objects going at small angles with the perpendicular to the given tomographic plane, the behaviour of the two-dimensional fourier-transform of the straight-line object in the course of the rotation of this object with respect to the specified axis in space, the scanning algorithm of the nuclear emulsion volume by the fence-like illuminated region in the mesooptical microscope for searching for particle tracks going parallel to the optical axis of the microscope, and, finally, the fact that the mesooptical images of the straight-line particle tracks with a common vertex in the nuclear emulsion lie on the sinogram. 12 refs.; 16 figs

  16. Bone densitometry with the computer tomograph

    International Nuclear Information System (INIS)

    Weiss, T.

    1978-01-01

    This work tests the usefulness of the EMI head scanner MARK I for a quantitative detection of ossary mineral content. Twenty-three concentration levels of a aqueous K 2 HPO 4 -solution were positioned by means of a special clamping device at the EMI-scanner and examined at tubevoltages of 100, 120 and 140 kV. This produces an almost linear dependence between CT-unit and sample concentration, whereby it shows that the measured special element densities of samples with the same densities vary in dependence with the voltage. The examination of an anotomical fore-arm preperate served as a statement for the reproductability of computer tomographic densitometry at non-moving biological objects. The test of reproductability of bone densitometry measurements under clinical conditions was made on the occation of the six time examinations of the right hand fore-arm bone of a young dummy. Furthermore densitometric examination were made at the fore-arm shelton of 40 long-time dialysis patients in the age levels between 17 and 67 years. The reproductability of the technique presented here is at least not better with the EMI-head-scanner MARK I used here. A change is possible by using the new whole body tomographs. (orig./MG) [de

  17. Comparative study of the macroscopic finding, conventional tomographic imaging, and computed tomographic imaging in locating the mandibular canal

    International Nuclear Information System (INIS)

    Choi, Hang Moon; You, Dong Soo

    1995-01-01

    The purpose of this study was comparison of conventional tomography with reformatted computed tomography for dental implant in locating the mandibular canal. Five dogs were used and after conventional tomographs and fitted computed tomographs were taken, four dentist traced all films. Mandibles were sectioned with 2 mm slice thickness and the sections were then radiographed (contact radiography). Each radiograpic image was traced and linear measurements were made from mandibular canal to alveolar crest, buccal cortex, lingual cortex, and inferior border. The following results were obtained; 1. Reformatted computed tomographs were exacter than conventional tomography by alveolar crest to canal length of -0.6 mm difference between real values and radiographs 2. The average measurements of buccal cortex to mandibular canal width and lingual cortex to mandibular canal width of conventional tomographs were exacter than reformatted computed tomographs, but standard deviations were higher than reformatted computed tomographs. 3. Standard deviations of reformatted computed tomographs were lower than conventional tomographs at all comparing sites 4. At reformatted computed tomography 62.5% of the measurements performed were within ±1 mm of the true value, and at conventional tomography 24.1% were. 5. Mandibular canal invisibility was 0.8% at reformatted computed tomography and 9.2% at conventional tomography. Reformatted computed tomography has been shown to be more useful radiographic technique for assessment of the mandibular canal than conventional tomography.

  18. An oral Salmonella-based vaccine inhibits liver metastases by promoting tumor-specific T cell-mediated immunity in celiac & portal lymph nodes. A preclinical study.

    Directory of Open Access Journals (Sweden)

    Alejandrina eVendrell

    2016-03-01

    Full Text Available Primary tumor excision is one of the therapies of cancer most widely used. However, the risk of metastases development still exists following tumor resection. The liver is a common site of metastatic disease for numerous cancers. Breast cancer is one of the most frequent source of metastases to the liver. The aim of this work was to evaluate the efficacy of the orally-administered Salmonella Typhi vaccine strain CVD 915 on the development of liver metastases in a mouse model of breast cancer. To this end, one group of BALB/c mice was immunized with CVD 915 via o.g. while another received PBS as a control. After 24 h, mice were injected with LM3 mammary adenocarcinoma cells into the spleen and subjected to splenectomy. This oral Salmonella-based vaccine produced an antitumor effect, leading to a decrease in the number and volume of liver metastases. Immunization with Salmonella induced an early cellular immune response in mice. This innate stimulation rendered a large production of IFN-γ by intrahepatic immune cells (IHIC detected within 24 h. An antitumor adaptive immunity was found in the liver and celiac & portal lymph nodes (LDLN 21 days after oral bacterial inoculation. The antitumor immune response inside the liver was associated with increased CD4+ and DC cell populations as well as with an inflammatory infiltrate located around liver metastatic nodules. Enlarged levels of inflammatory cytokines (IFN-γ and TNF were also detected in IHIC. Furthermore, a tumor-specific production of IFN-γ and TNF as well as tumor-specific IFN-γ-producing CD8 T cells (CD8+IFN-γ+ were found in the celiac & portal lymph nodes of Salmonella-treated mice. This study provides first evidence for the involvement of LDLN in the development of an efficient cellular immune response against hepatic tumors, which resulted in the elimination of liver metastases after oral Salmonella-based vaccination.

  19. Preclinical investigation to compare different gadolinium-based contrast agents regarding their propensity to release gadolinium in vivo and to trigger nephrogenic systemic fibrosis-like lesions

    International Nuclear Information System (INIS)

    Sieber, Martin A.; Frenzel, Thomas; Golfier, Sven; Weinmann, Hanns-Joachim; Pietsch, Hubertus; Lengsfeld, Philipp; Schmitt-Willich, Heribert; Siegmund, Fred; Walter, Jakob

    2008-01-01

    Recent reports suggest that nephrogenic systemic fibrosis (NSF) is associated with the administration of gadolinium (Gd)-based contrast agents (GBCAs) and in particular with the stability of the Gd-complex. The aim of this investigation was to compare GBCAs and their potential to trigger NSF. Forty-two healthy male rats received repeated intravenous injections of six different GBCAs at high doses to simulate the exposure seen in patients with severe renal dysfunction. Histopathological and immunohistochemical analysis of the skin was performed, and the concentrations of Gd, zinc and copper were measured in several tissues by inductive coupled plasma atomic emission spectroscopy. Macroscopic and histological skin changes similar to those seen in NSF patients were only observed in rats receiving Omniscan. In addition, very high concentrations of Gd were observed in the animals treated with Omniscan, and, to a lesser extent, in animals treated with OptiMARK. Significantly lower levels of Gd were found after the treatment with ionic linear agents and even less after the treatment with macrocyclic agents. The data in this investigation strongly suggest that the stability of the Gd-complex is a key factor for the development of NSF-like symptoms in this experimental setting. (orig.)

  20. Pre-clinical evaluation of soybean-based wound dressings and dermal substitute formulations in pig healing and non-healing in vivo models

    Directory of Open Access Journals (Sweden)

    Rostislav V Shevchenko

    2014-10-01

    Full Text Available In the last decade, a new class of natural biomaterials derived from de-fatted soybean flour processed by either thermoset or extraction procedures has been developed. These biomaterials uniquely combine adaptability to various clinical applications to proven tissue regeneration properties. In the present work, the biomaterials were formulated either as hydrogel or as paste formulation and their potential as wound dressing material or as dermal substitute was assessed by two in vivo models in pig skin: The healing full-thickness punch biopsy model and the non-healing full-thickness polytetrafluoroethylene (PTFE chamber model. The results clearly show that collagen deposition is induced by the presence of these biomaterials. A unique pattern of early inflammatory response, eliciting neutrophils and controlling macrophage infiltration, is followed by tissue cell colonization of the wound bed with a significant deposition of collagen fibers. The study also highlighted the importance in the use of optimal formulations and appropriate handling upon implantation. In large size, non-healing wounds, wound dermis was best obtained with the paste formulation as hydrogels appeared to be too loose to ensure lasting scaffolding properties. On the contrary, packing of the granules during the application of paste reduced biomaterial degradation rate and prevent the penetration of newly vascularized tissue, thus impeding grafting of split-thickness autologous skin grafts on the dermal substitute base.

  1. Preclinical investigation to compare different gadolinium-based contrast agents regarding their propensity to release gadolinium in vivo and to trigger nephrogenic systemic fibrosis-like lesions

    Energy Technology Data Exchange (ETDEWEB)

    Sieber, Martin A.; Frenzel, Thomas; Golfier, Sven; Weinmann, Hanns-Joachim; Pietsch, Hubertus [Bayer Schering Pharma AG, TRG Diagnostic Imaging, Berlin (Germany); Lengsfeld, Philipp [Bayer Schering Pharma AG, GMA DG Diagnostic Imaging, Berlin (Germany); Schmitt-Willich, Heribert [Bayer Schering Pharma AG, GDD Diagnostic Imaging, Berlin (Germany); Siegmund, Fred; Walter, Jakob [Bayer Schering Pharma AG, Nonclinical Drug Safety, Berlin (Germany)

    2008-10-15

    Recent reports suggest that nephrogenic systemic fibrosis (NSF) is associated with the administration of gadolinium (Gd)-based contrast agents (GBCAs) and in particular with the stability of the Gd-complex. The aim of this investigation was to compare GBCAs and their potential to trigger NSF. Forty-two healthy male rats received repeated intravenous injections of six different GBCAs at high doses to simulate the exposure seen in patients with severe renal dysfunction. Histopathological and immunohistochemical analysis of the skin was performed, and the concentrations of Gd, zinc and copper were measured in several tissues by inductive coupled plasma atomic emission spectroscopy. Macroscopic and histological skin changes similar to those seen in NSF patients were only observed in rats receiving Omniscan. In addition, very high concentrations of Gd were observed in the animals treated with Omniscan, and, to a lesser extent, in animals treated with OptiMARK. Significantly lower levels of Gd were found after the treatment with ionic linear agents and even less after the treatment with macrocyclic agents. The data in this investigation strongly suggest that the stability of the Gd-complex is a key factor for the development of NSF-like symptoms in this experimental setting. (orig.)

  2. Preclinical acute toxicity studies and rodent-based dosimetry estimates of the novel sigma-1 receptor radiotracer [18F]FPS

    International Nuclear Information System (INIS)

    Waterhouse, Rikki N.; Stabin, Michael G.; Page, John G.

    2003-01-01

    [ 18 F]1-(Fluoropropyl)-4-[(4-cyanophenoxy)methyl]piperidine ([ 18 F]FPS) is a novel high affinity (KD = 0.5 nM) sigma receptor radioligand that exhibits saturable and selective in vivo binding to sigma receptors in rats, mice and non-human primates. In order to support an IND application for the characterization of [ 18 F]FPS through PET imaging studies in humans, single organ and whole body radiation adsorbed doses associated with [ 18 F]FPS injection were estimated from distribution data obtained in rats. In addition, acute toxicity studies were conducted in rats and rabbits and limited toxicity analyses were performed in dogs. Radiation dosimetry estimates obtained using rat biodistribution analysis of [ 18 F]FPS suggest that most organs would receive around 0.012-0.015 mGy/MBq. The adrenal glands, brain, kidneys, lungs, and spleen would receive slightly higher doses (0.02-0.03 mGy/MBq). The adrenal glands were identified as the organs receiving the greatest adsorbed radiation dose. The total exposure resulting from a 5 mCi administration of [ 18 F]FPS is well below the FDA defined limits for yearly cumulative and per study exposures to research participants. Extended acute toxicity studies in rats and rabbits, and limited acute toxicity studies in beagle dogs suggest at least a 175-fold safety margin in humans at a mass dose limit of 2.8 μg per intravenous injection. This estimate is based on the measured no observable effect doses (in mg/m 2 ) in these species. These data support the expectation that [ 18 F]FPS will be safe for use in human PET imaging studies at a maximum administration of 5 mCi and a mass dose equal to or less than 2.8 μg FPS per injection

  3. Preclinical acute toxicity studies and rodent-based dosimetry estimates of the novel sigma-1 receptor radiotracer [(18)F]FPS.

    Science.gov (United States)

    Waterhouse, Rikki N; Stabin, Michael G; Page, John G

    2003-07-01

    [(18)F]1-(Fluoropropyl)-4-[(4-cyanophenoxy)methyl]piperidine ([(18)F]FPS) is a novel high affinity (KD = 0.5 nM) sigma receptor radioligand that exhibits saturable and selective in vivo binding to sigma receptors in rats, mice and non-human primates. In order to support an IND application for the characterization of [(18)F]FPS through PET imaging studies in humans, single organ and whole body radiation adsorbed doses associated with [(18)F]FPS injection were estimated from distribution data obtained in rats. In addition, acute toxicity studies were conducted in rats and rabbits and limited toxicity analyses were performed in dogs. Radiation dosimetry estimates obtained using rat biodistribution analysis of [(18)F]FPS suggest that most organs would receive around 0.012-0.015 mGy/MBq. The adrenal glands, brain, kidneys, lungs, and spleen would receive slightly higher doses (0.02-0.03 mGy/MBq). The adrenal glands were identified as the organs receiving the greatest adsorbed radiation dose. The total exposure resulting from a 5 mCi administration of [(18)F]FPS is well below the FDA defined limits for yearly cumulative and per study exposures to research participants. Extended acute toxicity studies in rats and rabbits, and limited acute toxicity studies in beagle dogs suggest at least a 175-fold safety margin in humans at a mass dose limit of 2.8 microg per intravenous injection. This estimate is based on the measured no observable effect doses (in mg/m(2)) in these species. These data support the expectation that [(18)F]FPS will be safe for use in human PET imaging studies at a maximum administration of 5 mCi and a mass dose equal to or less than 2.8 microg FPS per injection.

  4. Predator-based psychosocial stress animal model of PTSD: Preclinical assessment of traumatic stress at cognitive, hormonal, pharmacological, cardiovascular and epigenetic levels of analysis.

    Science.gov (United States)

    Zoladz, Phillip R; Diamond, David M

    2016-10-01

    Research on post-traumatic stress disorder (PTSD) is faced with the challenge of understanding how a traumatic experience produces long-lasting detrimental effects on behavior and brain functioning, and more globally, how stress exacerbates somatic disorders, including cardiovascular disease. Moreover, the design of translational research needs to link animal models of PTSD to clinically relevant risk factors which address why only a subset of traumatized individuals develop persistent psychopathology. In this review, we have summarized our psychosocial stress rodent model of PTSD which is based on well-described PTSD-inducing risk factors, including a life-threatening experience, a sense of horror and uncontrollability, and insufficient social support. Specifically, our animal model of PTSD integrates acute episodes of inescapable exposure of immobilized rats to a predator with chronic daily social instability. This stress regimen produces PTSD-like effects in rats at behavioral, cognitive, physiological, pharmacological and epigenetic levels of analysis. We have discussed a recent extension of our animal model of PTSD in which stress exacerbated coronary pathology following an ischemic event, assessed in vitro. In addition, we have reviewed our research investigating pharmacological and non-pharmacological therapeutic strategies which may have value in clinical approaches toward the treatment of traumatized people. Overall, our translational approach bridges the gap between human and animal PTSD research to create a framework with which to enhance our understanding of the biological basis of trauma-induced pathology and to assess therapeutic approaches in the treatment of psychopathology. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Preclinical acute toxicity studies and rodent-based dosimetry estimates of the novel sigma-1 receptor radiotracer [{sup 18}F]FPS

    Energy Technology Data Exchange (ETDEWEB)

    Waterhouse, Rikki N. E-mail: rn27@columbia.edu; Stabin, Michael G.; Page, John G

    2003-05-01

    [{sup 18}F]1-(Fluoropropyl)-4-[(4-cyanophenoxy)methyl]piperidine ([{sup 18}F]FPS) is a novel high affinity (KD = 0.5 nM) sigma receptor radioligand that exhibits saturable and selective in vivo binding to sigma receptors in rats, mice and non-human primates. In order to support an IND application for the characterization of [{sup 18}F]FPS through PET imaging studies in humans, single organ and whole body radiation adsorbed doses associated with [{sup 18}F]FPS injection were estimated from distribution data obtained in rats. In addition, acute toxicity studies were conducted in rats and rabbits and limited toxicity analyses were performed in dogs. Radiation dosimetry estimates obtained using rat biodistribution analysis of [{sup 18}F]FPS suggest that most organs would receive around 0.012-0.015 mGy/MBq. The adrenal glands, brain, kidneys, lungs, and spleen would receive slightly higher doses (0.02-0.03 mGy/MBq). The adrenal glands were identified as the organs receiving the greatest adsorbed radiation dose. The total exposure resulting from a 5 mCi administration of [{sup 18}F]FPS is well below the FDA defined limits for yearly cumulative and per study exposures to research participants. Extended acute toxicity studies in rats and rabbits, and limited acute toxicity studies in beagle dogs suggest at least a 175-fold safety margin in humans at a mass dose limit of 2.8 {mu}g per intravenous injection. This estimate is based on the measured no observable effect doses (in mg/m{sup 2}) in these species. These data support the expectation that [{sup 18}F]FPS will be safe for use in human PET imaging studies at a maximum administration of 5 mCi and a mass dose equal to or less than 2.8 {mu}g FPS per injection.

  6. Tomographic anthropomorphic models. Pt. 2. Organ doses from computed tomographic examinations in paediatric radiology

    International Nuclear Information System (INIS)

    Zankl, M.; Panzer, W.; Drexler, G.

    1993-11-01

    This report provides a catalogue of organ dose conversion factors resulting from computed tomographic (CT) examinations of children. Two radiation qualities and two exposure geometries were simulated as well as the use of asymmetrical beams. The use of further beam shaping devices was not considered. The organ dose conversion factors are applicable to babies at the age of ca. 2 months and to children between 5 and 7 years but can be used for other ages as well with the appropriate adjustments. For the calculations, the patients were represented by the GSF tomographic anthropomorphic models BABY and CHILD. The radiation transport in the body was simulated using a Monte Carlo method. The doses are presented as conversion factors of mean organ doses per air kerma free in air on the axis of rotation. Mean organ dose conversion factors are given per organ and per scanned body section of 1 cm height. The mean dose to an organ resulting from a particular CT examination can be estimated by summing up the contributions to the organ dose from all relevant sections. To facilitate the selection of the appropriate sections, a table is given which relates the tomographic models' coordinates to certain anatomical landmarks in the human body. (orig.)

  7. Collimated trans-axial tomographic scintillation camera

    International Nuclear Information System (INIS)

    1980-01-01

    The objects of this invention are first to reduce the time required to obtain statistically significant data in trans-axial tomographic radioisotope scanning using a scintillation camera. Secondly, to provide a scintillation camera system to increase the rate of acceptance of radioactive events to contribute to the positional information obtainable from a known radiation source without sacrificing spatial resolution. Thirdly to reduce the scanning time without loss of image clarity. The system described comprises a scintillation camera detector, means for moving this in orbit about a cranial-caudal axis relative to a patient and a collimator having septa defining apertures such that gamma rays perpendicular to the axis are admitted with high spatial resolution, parallel to the axis with low resolution. The septa may be made of strips of lead. Detailed descriptions are given. (U.K.)

  8. Collimated trans-axial tomographic scintillation camera

    International Nuclear Information System (INIS)

    1980-01-01

    The principal problem in trans-axial tomographic radioisotope scanning is the length of time required to obtain meaningful data. Patient movement and radioisotope migration during the scanning period can cause distortion of the image. The object of this invention is to reduce the scanning time without degrading the images obtained. A system is described in which a scintillation camera detector is moved to an orbit about the cranial-caudal axis relative to the patient. A collimator is used in which lead septa are arranged so as to admit gamma rays travelling perpendicular to this axis with high spatial resolution and those travelling in the direction of the axis with low spatial resolution, thus increasing the rate of acceptance of radioactive events to contribute to the positional information obtainable without sacrificing spatial resolution. (author)

  9. Computer tomographic and sonographic diagnosis of echinococcus

    Energy Technology Data Exchange (ETDEWEB)

    Schulze, K.; Huebener, K.H.; Klott, K.; Jenss, H.; Baehr, R. (Tuebingen Univ. (Germany, F.R.). Medizinisches Strahleninstitut und Roentgenabteilung; Tuebingen Univ. (Germany, F.R.). Medizinische Klinik; Tuebingen Univ. (Germany, F.R.). Chirurgische Klinik und Poliklinik)

    1980-05-01

    In 33 patients (18 cystic echinococci, 15 alveolar) both methods produced the following findings which could be correlated with the pathological results: single or multi-centric lesions, sharp or indefinite demarkation and abnormalities in the shape and size of the liver. The sonographic findings were analysed with respect to the echo characteristics, whereas the computer tomographically demonstrated lesions were examined densitometrically in order to show calcification. Both methods demonstrate the pathological changes satisfactorily. Computer tomography is more effective in alveolar echinococcus lesions by showing the different types of calcification, whereas sonography provides a more accurate picture of the internal structure of the cysts in cystic echinococcus. Comparison of the methods in 19 patients examined by both showed a high accuracy in each method, but sonography was relatively poor in demonstrating lesions in the spleen.

  10. Computerized tomographic scanner with shaped radiation filter

    International Nuclear Information System (INIS)

    Carlson, R.W.; Walters, R.G.

    1981-01-01

    The invention comprises a shaped filter and a filter correction circuitry for computerized tomographic scanners. The shaped filter is a generally u-shaped block of filter material which is adapted to be mounted between the source of radiation and the scan circle. The u-shaped block has a parabolic recess. The filter material may be beryllium, aluminum, sulphur, calcium, titanium, erbium, copper, and compounds including oxides and alloys thereof. The filter correction circuit comprises a first filter correction profile adding circuit for adding a first scaler valve to each intensity valve in a data line. The data line is operated on by a beam hardness correction polynomial. After the beam hardness polynomial correction operation, a second filter correction circuit adds a second filter correction profile consisting of a table of scalor values, one corresponding to each intensity reading in the data line

  11. Occult fractures of the knee: tomographic evaluation

    International Nuclear Information System (INIS)

    Apple, J.S.; Martinez, S.; Allen, N.B.; Caldwell, D.S.; Rice, J.R.

    1983-01-01

    Seven adults with painful effusions of the knee were examined for occult fractures using pluridirectional tomograph in the coronal and lateral planes. Six patients (ages 50 to 82 years) were osteopenic and gave histories ranging from none to mild trauma; one 26-year-old man was not osteopenic and had severe trauma. In all cases, routine radiographs were interpreted as negative, but tomography demonstrated a fracture. Five fractures were subchondral. Bone scans in 2 patients were positive. The authors conclude that osteopenic patients with a painful effusion of the knee should be considered to have an occult fracture. While bone scans may be helpful, tomography is recommended as the procedure of choice to define the location and extent of the fracture

  12. Axial tomographic system for radiation diagnoses

    International Nuclear Information System (INIS)

    Crowther, T.J.

    1977-01-01

    The axial tomographic scanner consists of a source of hard radiation passing a fan shaped beam through a plane layer of the body under examination, a detector, and driving systems for the sequential displacement and rotation of the radiation source and the detector. The diagnosis is made by means of a data processing system offering extensive time overlap capability of the individual system functions. The data sets from transmission or absorption are processed in three independent subsystems, i.e., the scanning system, the processing system and the display system. The systems are made up of well-known modules, e.g., Nova 1200 or Eclipse 5200. Hence, as a result of the independent design of the data system, raw data will not be lost in case of faults in some subsystem. (DG) [de

  13. Tomographic PIV behind a prosthetic heart valve

    Science.gov (United States)

    Hasler, D.; Landolt, A.; Obrist, D.

    2016-05-01

    The instantaneous three-dimensional velocity field past a bioprosthetic heart valve was measured using tomographic particle image velocimetry. Two digital cameras were used together with a mirror setup to record PIV images from four different angles. Measurements were conducted in a transparent silicone phantom with a simplified geometry of the aortic root. The refraction indices of the silicone phantom and the working fluid were matched to minimize optical distortion from the flow field to the cameras. The silicone phantom of the aorta was integrated in a flow loop driven by a piston pump. Measurements were conducted for steady and pulsatile flow conditions. Results of the instantaneous, ensemble and phase-averaged flow field are presented. The three-dimensional velocity field reveals a flow topology, which can be related to features of the aortic valve prosthesis.

  14. Computed tomographic findings of cerebral arterial ectasia

    International Nuclear Information System (INIS)

    Choi, Woo Suk; Ko, Young Ho; Lim, Jae Hoon

    1987-01-01

    The computed tomographic findings of cerebral arterial ectasia in 8 patients, of which 5 cases were angiographically documented, are reported. The ecstatic arteries, located predominantly in the suprasellar and interpeduncular cisterns, appeared as serpignous, tubular structures on the unenhanced scan. The enhanced CT scan demonstrated dense, sharply defined, homogeneous intraluminal enhancement. Until recently, the diagnosis of cerebral arterial ectasia was usually established by angiography. With introduction of CT it has become possible to noninvasively identify and characterize this vascular disorder and its associated intracranial complications. The vertebrobasilar dolichoectasia may be diagnosed by CT as an extra-axial lesion in the cerebellopontine angle. It enhances in a tubular fashion after intravenous injection of contrast.

  15. Computed tomographic investigations on intraventricular hematomas

    International Nuclear Information System (INIS)

    Laber-Szillat, S.

    1982-01-01

    This work investigated in 106 patients with intraventricular hematomas all the known factors which can have an influence on prognosis: age, sex, anamnesis of the patients, size, extent and localization of the intracranial bleeding, underlying angiopathy and differences between arterial and venous and spontaneous and traumatic bleedings. It was shown that the state of mind was the deciding prognostic factor, whereby viligance was the cumulative expression of all other investigated influences. A computed tomography (CT) examination is deciding in the question of operative hydrocephalus care. In 13 patients it was further shown, how clearly CT results and brain dissection allowed themselves to be compared. The computed tomographic examination method is best suited to achieve even physiological and more extensive prognostic possibilities. (orig.) [de

  16. Theoretical Exploration of the Neural Bases of Behavioural Disinhibition, Apathy and Executive Dysfunction in Preclinical Alzheimer's Disease in People with Down's Syndrome: Potential Involvement of Multiple Frontal-Subcortical Neuronal Circuits

    Science.gov (United States)

    Ball, S. L.; Holland, A. J.; Watson, P. C.; Huppert, F. A.

    2010-01-01

    Background: Recent research has suggested a specific impairment in frontal-lobe functioning in the preclinical stages of Alzheimer's disease (AD) in people with Down's syndrome (DS), characterised by prominent changes in personality or behaviour. The aim of the current paper is to explore whether particular kinds of change (namely executive…

  17. Recovering the triple coincidence of non-pure positron emitters in preclinical PET

    Science.gov (United States)

    Lin, Hsin-Hon; Chuang, Keh-Shih; Chen, Szu-Yu; Jan, Meei-Ling

    2016-03-01

    Non-pure positron emitters, with their long half-lives, allow for the tracing of slow biochemical processes which cannot be adequately examined by the commonly used short-lived positron emitters. Most of these isotopes emit high-energy cascade gamma rays in addition to positron decay that can be detected and create a triple coincidence with annihilation photons. Triple coincidence is discarded in most scanners, however, the majority of the triple coincidence contains true photon pairs that can be recovered. In this study, we propose a strategy for recovering triple coincidence events to raise the sensitivity of PET imaging for non-pure positron emitters. To identify the true line of response (LOR) from a triple coincidence, a framework utilizing geometrical, energy and temporal information is proposed. The geometrical criterion is based on the assumption that the LOR with the largest radial offset among the three sub pairs of triple coincidences is least likely to be a true LOR. Then, a confidence time window is used to test the valid LOR among those within triple coincidence. Finally, a likelihood ratio discriminant rule based on the energy probability density distribution of cascade and annihilation gammas is established to identify the true LOR. An Inveon preclinical PET scanner was modeled with GATE (GEANT4 application for tomographic emission) Monte Carlo software. We evaluated the performance of the proposed method in terms of identification fraction, noise equivalent count rates (NECR), and image quality on various phantoms. With the inclusion of triple coincidence events using the proposed method, the NECR was found to increase from 11% to 26% and 19% to 29% for I-124 and Br-76, respectively, when 7.4-185 MBq of activity was used. Compared to the reconstructed images using double coincidence, this technique increased the SNR by 5.1-7.3% for I-124 and 9.3-10.3% for Br-76 within the activity range of 9.25-74 MBq, without compromising the spatial resolution or

  18. [Impact of microdose clinical trials in the preclinical stage].

    Science.gov (United States)

    Kim, Soonih

    2014-01-01

    A microdose clinical trial may be useful as a safe early-phase exploratory study using doses as low as 100 μg or less for determination of the disposition of a candidate compound in humans in a short period of time. This may increase confidence in candidate compounds, especially those for which it is difficult to predict disposition based on the results of in vitro or preclinical studies. In this study, we examined microdose trials performed in the preclinical stage for two first-in-class compounds with a new mechanism of action. These compounds showed species difference in first pass metabolism in the digestive tract and liver, causing uncertainty in prediction of disposition in humans. For this reason, first-in-human microdose clinical trials were performed. The results showed that the two compounds had effective blood concentrations after oral administration at a dose of 100 mg qd. Administration of an extremely small dose of one (14)C-labeled compound permitted identification of major metabolites. No toxic metabolites were detected. The preclinical toxic dose was determined based on prediction of blood exposure at the estimated maximum clinical dose. For the other candidate compound, the findings of the microdose trial indicated a high bioavailability after oral administration and low hepatic clearance after intravenous administration. These results suggested only a small risk of a change in disposition in patients with hepatic disorder. The data obtained for the two compounds suggest that microdose clinical trials can be useful for improving the process of candidate selection in the preclinical stage.

  19. A 3D tomographic EBSD analysis of a CVD diamond thin film

    International Nuclear Information System (INIS)

    Liu Tao; Raabe, Dierk; Zaefferer, Stefan

    2008-01-01

    We have studied the nucleation and growth processes in a chemical vapor deposition (CVD) diamond film using a tomographic electron backscattering diffraction method (3D EBSD). The approach is based on the combination of a focused ion beam (FIB) unit for serial sectioning in conjunction with high-resolution EBSD. Individual diamond grains were investigated in 3-dimensions particularly with regard to the role of twinning.

  20. A 3D tomographic EBSD analysis of a CVD diamond thin film

    Directory of Open Access Journals (Sweden)

    Tao Liu, Dierk Raabe and Stefan Zaefferer

    2008-01-01

    Full Text Available We have studied the nucleation and growth processes in a chemical vapor deposition (CVD diamond film using a tomographic electron backscattering diffraction method (3D EBSD. The approach is based on the combination of a focused ion beam (FIB unit for serial sectioning in conjunction with high-resolution EBSD. Individual diamond grains were investigated in 3-dimensions particularly with regard to the role of twinning.

  1. A cost-effective simulation curriculum for preclinical endodontics.

    Science.gov (United States)

    Pileggi, Roberta; Glickman, Gerald N

    2004-02-01

    A challenge in contemporary dental education is to achieve a smooth transition from preclinical teaching environments to patient-care clinics in a cost-effective manner. The preclinical endodontic courses at The University of Texas, Dental Branch at Houston provide a unique learning environment that enables the student to perform endodontic treatment on extracted teeth in a typodont, and be involved in diagnosis and treatment-planning discussions. The specially designed stone typodont used has built-in radiographic capability, and is mounted at each chair in the clinic. During each preclinical session, students are assigned clinical cubicles and proper aseptic protocol is followed. Students are required to wear gloves, masks and eyewear, and place a rubber dam during treatment. Written self-assessment evaluations based upon prescribed criteria are utilised; feedback is given by faculty composed of both full-time endodontists and graduate students who periodically rotate and are calibrated on a regular basis. In the lecture phase, clinical case scenarios are presented to reinforce concepts of diagnosis and emergency care and to help integrate endodontics with other disciplines; a Socratic-like teaching style is established by the faculty facilitator to create an environment for developing critical-thinking and problem-solving skills. The overall feedback from graduating students has been very positive. Advantages of this format are an easier transition to patient management, a more keen interest in specialsation and a perceived increase in levels of confidence.

  2. Radiographic test phantom for computed tomographic lung nodule analysis

    International Nuclear Information System (INIS)

    Zerhouni, E.A.

    1987-01-01

    This patent describes a method for evaluating a computed tomograph scan of a nodule in a lung of a human or non-human animal. The method comprises generating a computer tomograph of a transverse section of the animal containing lung and nodule tissue, and generating a second computer tomograph of a test phantom comprising a device which simulates the transverse section of the animal. The tissue simulating portions of the device are constructed of materials having radiographic densities substantially identical to those of the corresponding tissue in the simulated transverse section of the animal and have voids therein which simulate, in size and shape, the lung cavities in the transverse section and which contain a test reference nodule constructed of a material of predetermined radiographic density which simulates in size, shape and position within a lung cavity void of the test phantom the nodule in the transverse section of the animal and comparing the respective tomographs

  3. Computed tomographic determination of tracheal dimensions in children and adolescents

    International Nuclear Information System (INIS)

    Griscom, N.T.

    1982-01-01

    A computed tomographic system for determining the internal diameters, cross-sectional area, and length of the trachea in children and adolescents was developed. Intraluminal volumes were calculated from these measurements.The results of 18 analyses are reported

  4. Tomographic imaging of subducted lithosphere below northwest Pacific island arcs

    Science.gov (United States)

    Van Der Hilst, R.; Engdahl, R.; Spakman, W.; Nolet, G.

    1991-01-01

    The seismic tomography problem does not have a unique solution, and published tomographic images have been equivocal with regard to the deep structure of subducting slabs. An improved tomographic method, using a more realistic background Earth model and surf ace-reflected as well as direct seismic phases, shows that slabs beneath the Japan and Izu Bonin island arcs are deflected at the boundary between upper and lower mantle, whereas those beneath the northern Kuril and Mariana arcs sink into the lower mantle.

  5. From tomographic images to fault heterogeneities

    Directory of Open Access Journals (Sweden)

    A. Amato

    1994-06-01

    Full Text Available Local Earthquake Tomography (LET is a useful tool for imaging lateral heterogeneities in the upper crust. The pattern of P- and S-wave velocity anomalies, in relation to the seismicity distribution along active fault zones. can shed light on the existence of discrete seismogenic patches. Recent tomographic studies in well monitored seismic areas have shown that the regions with large seismic moment release generally correspond to high velocity zones (HVZ's. In this paper, we discuss the relationship between the seismogenic behavior of faults and the velocity structure of fault zones as inferred from seismic tomography. First, we review some recent tomographic studies in active strike-slip faults. We show examples from different segments of the San Andreas fault system (Parkfield, Loma Prieta, where detailed studies have been carried out in recent years. We also show two applications of LET to thrust faults (Coalinga, Friuli. Then, we focus on the Irpinia normal fault zone (South-Central Italy, where a Ms = 6.9 earthquake occurred in 1980 and many thousands of attershock travel time data are available. We find that earthquake hypocenters concentrate in HVZ's, whereas low velocity zones (LVZ’ s appear to be relatively aseismic. The main HVZ's along which the mainshock rupture bas propagated may correspond to velocity weakening fault regions, whereas the LVZ's are probably related to weak materials undergoing stable slip (velocity strengthening. A correlation exists between this HVZ and the area with larger coseismic slip along the fault, according to both surface evidence (a fault scarp as high as 1 m and strong ground motion waveform modeling. Smaller wave-length, low-velocity anomalies detected along the fault may be the expression of velocity strengthening sections, where aseismic slip occurs. According to our results, the rupture at the nucleation depth (~ 10-12 km is continuous for the whole fault lenoth (~ 30 km, whereas at shallow depth

  6. The Economics of Reproducibility in Preclinical Research.

    Directory of Open Access Journals (Sweden)

    Leonard P Freedman

    2015-06-01

    Full Text Available Low reproducibility rates within life science research undermine cumulative knowledge production and contribute to both delays and costs of therapeutic drug development. An analysis of past studies indicates that the cumulative (total prevalence of irreproducible preclinical research exceeds 50%, resulting in approximately US$28,000,000,000 (US$28B/year spent on preclinical research that is not reproducible-in the United States alone. We outline a framework for solutions and a plan for long-term improvements in reproducibility rates that will help to accelerate the discovery of life-saving therapies and cures.

  7. Radiographic and tomographic study of the elbow joint in dogs

    International Nuclear Information System (INIS)

    Sendyk-Grunkraut, Alessandra; Martin, Claudia M.; Souza, Alexandre N.A.; Patricio, Geni Cristina F.; Lorigados, Carla A.B.; Matera, Julia M.; Fonseca-Pinto, Ana C.B.C.

    2017-01-01

    Elbow dysplasia disease includes an united anconeal process, fragmented medial coronoid process, osteochondrosis of humeral trochlea, articular incongruity and degenerative joint disease. The aim of this study was to present detailed morphologic and morphometric aspects of the elbow joint in dog in clinical and correlate with radiographic and tomographic (CT) exam. Inter-observer variation for articular incongruity measurements by CT, comparative analysis in the radiographic exam, angle in ulnar notch and its comparative analysis between radiographic and tomographic agreement examination in 44 elbow of dogs with different ages were evaluated. The statistics analyses included the kappa coefficient and interclass correlation and Fischer's test and McNemar's test. It was evidenced that individual performance of each radiographic incidence had poor agreement with the tomographic exam, suggesting that the accomplishment of more than two radiograph views are needed. There was no agreement between the three evaluators in the ulnar notch angle at radiographic and tomographic exams. However, there was good/moderate agreement for articular incongruity measurement in the sagittal plane between evaluators. It was possible to conclude that none of the five radiographic incidences was better than the others for radiographic analysis because each incidence had a better identification of a particular elbow compartment; measurements at the tomographic exam to evaluate radioulnar incongruity had no reproductiveness in the frontal plane, but in sagittal plan had a good/moderate agreement between observers and the angle in ulnar notch presented no repeatability at radiographic exam and no reproductiveness at tomographic exam. (author)

  8. Gamma Ray Tomographic Scan Method for Large Scale Industrial Plants

    International Nuclear Information System (INIS)

    Moon, Jin Ho; Jung, Sung Hee; Kim, Jong Bum; Park, Jang Geun

    2011-01-01

    The gamma ray tomography systems have been used to investigate a chemical process for last decade. There have been many cases of gamma ray tomography for laboratory scale work but not many cases for industrial scale work. Non-tomographic equipment with gamma-ray sources is often used in process diagnosis. Gamma radiography, gamma column scanning and the radioisotope tracer technique are examples of gamma ray application in industries. In spite of many outdoor non-gamma ray tomographic equipment, the most of gamma ray tomographic systems still remained as indoor equipment. But, as the gamma tomography has developed, the demand on gamma tomography for real scale plants also increased. To develop the industrial scale system, we introduced the gamma-ray tomographic system with fixed detectors and rotating source. The general system configuration is similar to 4 th generation geometry. But the main effort has been made to actualize the instant installation of the system for real scale industrial plant. This work would be a first attempt to apply the 4th generation industrial gamma tomographic scanning by experimental method. The individual 0.5-inch NaI detector was used for gamma ray detection by configuring circular shape around industrial plant. This tomographic scan method can reduce mechanical complexity and require a much smaller space than a conventional CT. Those properties make it easy to get measurement data for a real scale plant

  9. Investigation of the noise effect on tomographic reconstructions for a tangentially viewing vacuum ultraviolet imaging diagnostic

    International Nuclear Information System (INIS)

    Ming, Tingfeng; Ohdachi, Satoshi; Suzuki, Yasuhiro

    2011-01-01

    Tomographic reconstruction for a tangentially viewing two-dimensional (2D) imaging system is studied. A method to calculate the geometry matrix in 2D tomography is introduced. An algorithm based on a Phillips-Tikhonov (P-T) type regularization method is investigated, and numerical tests using the P-T method are conducted with both tokamak and Heliotron configurations. The numerical tests show that the P-T method is not sensitive to the added noise levels and the emission profiles with higher mode numbers can be reconstructed with adequate resolution. The results indicate that this method is suitable for 2D tomographic reconstruction for a tangentially viewing vacuum ultraviolet telescope system. (author)

  10. Suprathermal electron studies in the TCV tokamak: Design of a tomographic hard-x-ray spectrometer

    International Nuclear Information System (INIS)

    Gnesin, S.; Coda, S.; Decker, J.; Peysson, Y.

    2008-01-01

    Electron cyclotron resonance heating and electron cyclotron current drive, disruptive events, and sawtooth activity are all known to produce suprathermal electrons in fusion devices, motivating increasingly detailed studies of the generation and dynamics of this suprathermal population. Measurements have been performed in the past years in the tokamak a configuration variable (TCV) tokamak using a single pinhole hard-x-ray (HXR) camera and electron-cyclotron-emission radiometers, leading, in particular, to the identification of the crucial role of spatial transport in the physics of ECCD. The observation of a poloidal asymmetry in the emitted suprathermal bremsstrahlung radiation motivates the design of a proposed new tomographic HXR spectrometer reported in this paper. The design, which is based on a compact modified Soller collimator concept, is being aided by simulations of tomographic reconstruction. Quantitative criteria have been developed to optimize the design for the greatly variable shapes and positions of TCV plasmas.

  11. Motion tracking-enhanced MART for tomographic PIV

    International Nuclear Information System (INIS)

    Novara, Matteo; Scarano, Fulvio; Batenburg, Kees Joost

    2010-01-01

    A novel technique to increase the accuracy of multiplicative algebraic reconstruction technique (MART) reconstruction from tomographic particle image velocimetry (PIV) recordings at higher seeding density than currently possible is presented. The motion tracking enhancement (MTE) method is based on the combined utilization of images from two or more exposures to enhance the reconstruction of individual intensity fields. The working principle is first introduced qualitatively, and the mathematical background is given that explains how the MART reconstruction can be improved on the basis of an improved first guess object obtained from the combination of non-simultaneous views reduced to the same time instant deforming the 3D objects by an estimate of the particle motion field. The performances of MTE are quantitatively evaluated by numerical simulation of the imaging, reconstruction and image correlation processes. The cases of two or more exposures obtained from time-resolved experiments are considered. The iterative application of MTE appears to significantly improve the reconstruction quality, first by decreasing the intensity of the ghost images and second, by increasing the intensity and the reconstruction precision for the actual particles. Based on computer simulations, the maximum imaged seeding density that can be dealt with is tripled with respect to the MART analysis applied to a single exposure. The analysis also illustrates that the maximum effect of the MTE method is comparable to that of doubling the number of cameras in the tomographic system. Experiments performed on a transitional jet at Re = 5000 apply the MTE method to double-frame recordings. The velocity measurement precision is increased for a system with fewer views (two or three cameras compared with four cameras). The ghost particles' intensity is also visibly reduced although to a lesser extent with respect to the computer simulations. The velocity and vorticity field obtained from a three

  12. Preclinical Magnetic Resonance Fingerprinting (MRF) at 7 T: Effective Quantitative Imaging for Rodent Disease Models

    Science.gov (United States)

    Gao, Ying; Chen, Yong; Ma, Dan; Jiang, Yun; Herrmann, Kelsey A.; Vincent, Jason A.; Dell, Katherine M.; Drumm, Mitchell L.; Brady-Kalnay, Susann M.; Griswold, Mark A.; Flask, Chris A.; Lu, Lan

    2015-01-01

    High field, preclinical magnetic resonance imaging (MRI) scanners are now commonly used to quantitatively assess disease status and efficacy of novel therapies in a wide variety of rodent models. Unfortunately, conventional MRI methods are highly susceptible to respiratory and cardiac motion artifacts resulting in potentially inaccurate and misleading data. We have developed an initial preclinical, 7.0 T MRI implementation of the highly novel Magnetic Resonance Fingerprinting (MRF) methodology that has been previously described for clinical imaging applications. The MRF technology combines a priori variation in the MRI acquisition parameters with dictionary-based matching of acquired signal evolution profiles to simultaneously generate quantitative maps of T1 and T2 relaxation times and proton density. This preclinical MRF acquisition was constructed from a Fast Imaging with Steady-state Free Precession (FISP) MRI pulse sequence to acquire 600 MRF images with both evolving T1 and T2 weighting in approximately 30 minutes. This initial high field preclinical MRF investigation demonstrated reproducible and differentiated estimates of in vitro phantoms with different relaxation times. In vivo preclinical MRF results in mouse kidneys and brain tumor models demonstrated an inherent resistance to respiratory motion artifacts as well as sensitivity to known pathology. These results suggest that MRF methodology may offer the opportunity for quantification of numerous MRI parameters for a wide variety of preclinical imaging applications. PMID:25639694

  13. Reasons between effective doses for tomographic and mathematical models due to external exposition by photons

    International Nuclear Information System (INIS)

    Kramer, R.; Khoury, H.J.; Yoriyaz, H.; Lima, F.R.A.; Loureiro, E.C.M.

    2005-01-01

    The development of Monte Carlo codes and new and sophisticated tomographic human models, or based on voxel, motivated the ICRP to propose a revision of the traditional exposition models, which have been used to calculate doses on organs and tissues using mathematical phantoms MIRD-type 5. This article presents calculations made with tomographic phantoms MAX (Male Adult voXel) and FAX (Female Adult voXel), recently developed and also, for comparison, with ADAM and Eve mathematician phantoms. All models were coupled to the EGS4 and MCNP4 codes for full body external irradiation by photons. It were simulated expositions AP, PA and rotational for energies varying between 10 keV and 10 MeV. The effective calculated doses were compared separately to evaluate: the replacement of the Monte Carlo code; the composition of the tissues and the replacement of tomographic phantoms by mathematical ones. Effective doses calculated results indicate that for external exposures by photons to introduce models based on voxels can cause a reduction of about 10% to the energies considered in this study

  14. A tomographic approach to intravenous coronary arteriography

    International Nuclear Information System (INIS)

    Ritman, E.L.; Bove, A.A.

    1986-01-01

    Coronary artery anatomy can be visualized using high speed, volume scanning X-ray CT. A single scan during a bolus injection of contrast medium provides image data for display of all angles of view of the opacified coronary arterial tree. Due to the tomographic nature of volume image data the superposition of contrast filled cardiac chambers, such as would occur in the levophase of an intravenous injection of contrast agent, can be eliminated. Data are presented which support these statements. The Dynamic Spatial Reconstructor (DSR) was used to scan a life-like radiologic phantom of an adult human thorax in which the left atrial and ventricular chambers and the major epicardial coronary arteries were opacified so as to simulate the levophase of an intravenous injection of contrast agent. A catheter filled with diluted contrast agent and with regions of luminal narrowing (i.e. 'stenoses') was advanced along a tract equivalent to a right ventricular catheterization. Ease of visualization of the catheter 'stenoses' and the accuracy with which they can be measured are presented. (Auth.)

  15. Comparison among tomographic reconstruction with limited data

    International Nuclear Information System (INIS)

    Oliveira, Eric F.; Dantas, Carlos C.; Vasconcelos, Daniel A.A.; Cadiz, Luis F.; Melo, Silvio B.

    2011-01-01

    Nowadays there is a continuing interest in applying computed tomography (CT) techniques in non-destructive testing and inspection of many industrial products. These applications of CT usually require a differentiated analysis when there are strong limitations in acquiring a sufficiently large amount of projection data. The use of a low number of tomographic data normally degrades the quality of the reconstructed image, highlighting the formation of artifacts and noise. This work investigates the reconstruction methods most commonly used (FBP, ART, SIRT, MART, SMART) and shows the performance of each one in this limited scenario. For this purpose, all methods were implemented and tested with a phantom of uniform density with well-known distribution, with measures of transmission of gamma radiation in a first generation CT scanner. The phantom is a concentric stainless steel tube coupled with a half - cylinder of aluminum. The measurements were made with an highest root mean square error, with the formation of visible artifacts. The artifacts are diminished but still visible in the ART and SIRT techniques, and the best performance was observed with the techniques MART and SMART. The technical superiority of these multiplicative methods is clearly seen in the reconstructed image quality, endorsing their application to situations of limited input data. (author)

  16. Computed tomographic findings of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Jo, In Su; Jong, Woo Yung; Lee, Jong Yul; Choi, Han Yong; Kim, Bong Ki

    1987-01-01

    With Development of Computed Tomography, detection of the Hepatocellular Carcinoma are easily performed and frequently used in the world. During 15 months, from December 1985 to February 1987, 59 patients with hepatocellular carcinoma were evaluated with computed tomography in department of radiology at Wallace Memorial Baptist Hospital. The results were as follow: 1. The most prevalent age group was 5th to 7th decades, male to female ratio was 4.9:1. 2. Classification with incidence of computed tomographic appearance of the hepatocellular carcinoma were solitary type 28 cases (48%), multinodular type 24 cases (40%), and diffuse type 7 cases (12%), Association with liver cirrhosis was noted in 22 cases (38%). 3. Inhomogenous internal consistency of hepatocellular carcinoma due to central necrosis were 35 cases (60%). Portal vein invasion by hepatocellular carcinoma was noted in 15 cases (25%), and particularly most common in diffuse type 4 cases (55%). 4. On precontrast scan, all hepatocellular carcinoma were seen as area of low density except for 3 cases(0.5%) of near isodensity which turned out to be remarkable low density on postcontrast scan. 5. In solitary type, posterior segment of right lobe was most common site of involvement 12 cases (43%). In diffuse type, bilobar involvement was most common, 6 cases (85%)

  17. Computerized tomographic studies in cerebral palsy

    International Nuclear Information System (INIS)

    Sugie, Yoko

    1981-01-01

    Computed tomographic (CT) findings in 200 children with cerebral palsy (CP) were analysed from the viewpoint of clinical manifestations, disease complications and etiological factors. CT scans of 135 cases (67.5%) were found to be abnormal and there were 14 (7%) borderline cases. The major abnormality found on CT scans was cerebral atrophy. Other important changes included focal or diffuse low density area in the brain tissue, congenital malformation, and cerebellar atrophy. From the clinical point of view, a large number of patients with spastic tetraplegia and spastic diplegia showed highly abnormal CT scans. On the other hand, in patients with spastic monoplegia, spastic paraplegia, and athetotic type, CT findings were normal or revealed only minor cerebral atrophy. Most children showing asymmetric clinical symptoms had corresponding asymmetric CT abnormalities which included ventricular enlargement, low density area in the brain tissue, and hemispherical volume. There was a significant correlation between the severity of physical impairment and the extent of CT abnormalities. Severely affected children had grossly abnormal CT scans such as hydranencephaly, polycystic change, and extensive cerebral atrophy. In the patients complicated with epilepsy, the incidence and severity of abnormal CT were higher than those of non-epileptic patients. Mentally retarded patients had variable enlargement of the subarachnoidal space depending on the severity of their mental retardation. Patients with suspected postnatal etiology also had high incidence of severe CT abnormality. CT scan is a valuable tool for evaluating patients with CP and in some cases, possible etiology of the disease may be discovered. (author)

  18. Computed tomographic findings of intracerebral cysticercosis

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Jin Kyo; Lee, Sun Wha; Kim, Ho Kyun; Ahn, Chi Yul [School of Medicine, Kyung-Hee University, Seoul (Korea, Republic of)

    1980-12-15

    Cysticercosis is a parasitic disease in which man serves as the intermediate host of Taenia Solium, the pork tapeworm. The computed tomographic findings of 25 cases of intracerebral cysticercosis proven by pathologic and/or clinical findings during past 2 years were analysed. The results were as follows; 1. The sex was 19 males and 6 females, and 56 percent of the patients were seen in fourth and fifth decades. The most common symptom was epilepsy (72%). 2. The C. T. findings in precontrast study were varied; such as ill defined low density (48%), cystic low density (20%), dilated ventricles (20%), ill defined low density with isodense nodule (18%), cystic low density with isodense mural nodule (12%) and calcification (8%). 3. The areas of involvement were 20 cases (80%) of parenchymal form, 3 cases (12%) of ventricular form and 2 cases (8%) of mixed form. 4. The contrast-enhanced 13 cases were 5 nodular, 5 ring or rim-like and 3 mixed type enhancements, while 12 cases were not enhanced. 5. C.T. scan demonstrated more precise location and extents of cerebral cysticercosis, especially in parenchymal form. It was considered to be important in determination of surgical feasibility and its approach.

  19. Distance weighting for improved tomographic reconstructions

    International Nuclear Information System (INIS)

    Koeppe, R.A.; Holden, J.E.

    1984-01-01

    An improved method for the reconstruction of emission computed axial tomography images has been developed. The method is a modification of filtered back-projection, where the back projected values are weighted to reflect the loss of formation, with distance from the camera, which is inherent in gamma camera imaging. This information loss is a result of: loss of spatial resolution with distance, attenuation, and scatter. The weighting scheme can best be described by considering the contributions of any two opposing views to the reconstruction image pixels. The weight applied to the projections of one view is set to equal the relative amount of the original activity that was initially received in that projection, assuming a uniform attenuating medium. This yields a weighting value which is a function of distance into the image with a value of one for pixels ''near the camera'', a value of .5 at the image center, and a value of zero on the opposite side. Tomographic reconstructions produced with this method show improved spatial resolution when compared to conventional 360 0 reconstructions. The improvement is in the tangential direction, where simulations have indicated a FWHM improvement of 1 to 1.5 millimeters. The resolution in the radial direction is essentially the same for both methods. Visual inspection of the reconstructed images show improved resolution and contrast

  20. Formation of tomographic images with neutrons

    International Nuclear Information System (INIS)

    Duarte, A.; Tenreiro, C; Valencia, J; Steinman, G.; Henriquez, C

    2000-01-01

    The possibility of having a non-destructive method of analysis for archaeological and paleontological samples is of interest. A special group of fossil samples has come to our attention, which because of their value should be preserved and, therefore, the availability of an indirect, non-destructive, non contaminating analytical technique is important. The strong absorption of usual kinds of radiation by a fossilized sample restricts the application of conventional methods of analysis. A type of radiation that is not completely attenuated by thick samples, in sizes that are typical in paleontology, is necessary. Neutrons may be considered as an ideal non-invasive probe with the possibility of developing a technique for the formation and analysis of images. A technique has been developed for the spatial reconstruction of the contents of a fossilized sample (tomography) with neutrons, without touching or altering the sample in any way. The neutron beam was extracted from the RECH-1 reactor belonging to the CCHEN, La Reina. The tomographic images of the contents of a fossilized egg are presented for the first time and represent views or cuts of the content as well as a set that permits the three dimensional reconstruction of the inside of the object and its subsequent animation in graphic format. This project developed a technique for taking neutron radiographs of this kind of sample including the numerical algorithms and the treatment and formation of the images (CW)

  1. Method and apparatus for producing tomographic images

    International Nuclear Information System (INIS)

    Annis, M.

    1989-01-01

    A device useful in producing a tomographic image of a selected slice of an object to be examined is described comprising: a source of penetrating radiation, sweep means for forming energy from the source into a pencil beam and repeatedly sweeping the pencil beam over a line in space to define a sweep plane, first means for supporting an object to be examined so that the pencil beam intersections the object along a path passing through the object and the selected slice, line collimating means for filtering radiation scattered by the object, the line collimating means having a field of view which intersects and sweep plane in a bounded line so that the line collimating means passes only radiation scattered by elementary volumes of the object lying along the bounded line, and line collimating means including a plurality of channels such substantially planar in form to collectively define the field of view, the channels oriented so that pencil beam sweeps along the bounded line as a function of time, and radiation detector means responsive to radiation passed by the line collimating means

  2. Computed tomographic findings of cerebral paragonimiasis

    International Nuclear Information System (INIS)

    Sung, Nak Kwan; Nam, Kyung Jin; Park, Churl Min; Eun, Chung Kie; Lee, Sun Wha

    1983-01-01

    Paragonimiasis is widely distributed in Far East and Southeast Asia, particularly in Korea. The central nervous system is the most frequent location for paragonimiasis outside the lungs. We analyzed the computed tomographic findings of 17 cases which were diagnosed pathologically and clinically as cerebral paragonimiasis. The results were as follows: 1. The ratio of male to female was 10 : 7 and about 88% of cases were under the age of 40 years. 2. The common locations of cerebral paragonimiasis were the occipital (12 cases) and temporal (11 cases) lobes. 3. Precontrast CT findings of cerebral paragonimiasis were low density with calcifications in 6 cases, low and isodensities in 4 cases, mixed densities in 3 cases, only low density in 2 cases and only calcification in 2 cases. Hydrocephalus (7 cases), mass effect (6 cases), atrophic change (6 cases) and cyst formation (3 cases) were associated. 4. The shape of calcifications in CT scan were soap-bubble or ring in 6 cases, nodular or oval in 6 cases, stipple in 4 cases and amorphous conglomerated in 2 cases. 5. The contrast -enhanced 8 cases were 5 ring or rim like, 2 nodular and 1 irregular enhancements, while 9 cases were not enhanced

  3. Collimator trans-axial tomographic scintillation camera

    International Nuclear Information System (INIS)

    Jaszczak, Ronald J.

    1979-01-01

    An improved collimator is provided for a scintillation camera system that employs a detector head for transaxial tomographic scanning. One object of this invention is to significantly reduce the time required to obtain statistically significant data in radioisotope scanning using a scintillation camera. Another is to increase the rate of acceptance of radioactive events to contribute to the positional information obtainable from a radiation source of known strength without sacrificing spatial resolution. A further object is to reduce the necessary scanning time without degrading the images obtained. The collimator described has apertures defined by septa of different radiation transparency. The septa are aligned to provide greater radiation shielding from gamma radiation travelling within planes perpendicular to the cranial-caudal axis and less radiation shielding from gamma radiation travelling within other planes. Septa may also define apertures such that the collimator provides high spatial resolution of gamma rays traveling within planes perpendicular to the cranial-caudal axis and directed at the detector and high radiation sensitivity to gamma radiation travelling other planes and indicated at the detector. (LL)

  4. Tomographic inversion of P and pP data for aspherical mantle structure below the northwest Pacific region

    NARCIS (Netherlands)

    Hilst, R.D. van der; Engdahl, E.R.; Spakman, W.

    1993-01-01

    To investigate the morphology of subducted slab in the mantle below northwest Pacific island arcs we inverted traveltime residuals for aspherical variations in P-wave propagation velocity relative to the radially symmetric iasp91 reference model. The tomographic method used is based on a step-wise

  5. Radiographic and tomographic aspects of meningeal hemangiosarcoma in a German Shepherd dog with clinical signs of cauda equina sindrome

    International Nuclear Information System (INIS)

    Pinto, A.C.B. de C.F.; Ferrigno, C.R.A.; Matera, J.M.; Torres, L.N.; Sinhorini, I.L.; Cortopassi, S.R.G.; Hage, M.C.F.N.S.

    2007-01-01

    Hemangiosarcoma is a highly malignant neoplasia derived from the endothelial cell line and, therefore, can arise in any tissue with blood vessels. A case of a rare meningeal site of hemangiosarcoma in an eight-year old German Shepherd dog with clinical signs of cauda equina sindrome is described. The diagnosis was made based on clinical, radiographic, tomographic and histopathological findings [pt

  6. Evaluation and optimization of the High Resolution Research Tomograph (HRRT)

    International Nuclear Information System (INIS)

    Knoess, C.

    2004-01-01

    Positron Emission Tomography (PET) is an imaging technique used in medicine to determine qualitative and quantitative metabolic parameters in vivo. The High Resolution Research Tomograph (HRRT) is a new high resolution tomograph that was designed for brain studies (312 mm transaxial field-of-view (FOV), 252 mm axial FOV). The detector blocks are arranged in a quadrant sharing design and consist of two crystal layers with dimensions of 2.1 mm x 2.1 mm x 7.5 mm. The main detector material is the newly developed scintillator lutetium oxyorthosilicate (LSO). Events from the different crystal layers are distinguished by Pulse Shape Discrimination (PSD) to gain Depth of Interaction (DOI) information. This will improve the spatial resolution, especially at the edges of the FOV. A prototype of the tomograph was installed at the Max-Planck Institute for Neurological Research in Cologne, Germany in 1999 and was evaluated with respect to spatial resolution, sensitivity, scatter fraction, and count rate behavior. These performance measurements showed that this prototype provided a spatial resolution of around 2.5 mm in a volume big enough to contain the human brain. A comparison with a single layer HRRT prototype showed a 10% worsening of the resolution, despite the fact that DOI was used. Without DOI, the resolution decreased considerably. The sensitivity, as measured with a 22 Na point source, was 46.5 cps/kBq for an energy window of 350-650 keV and 37.9 cps/kBq for an energy window of 400-650 keV, while the scatter fractions were 56% for 350-650 keV and 51% for 400-650 keV, respectively. A daily quality check was developed and implemented that uses the uniform, natural radioactive background of the scintillator material LSO. In 2001, the manufacturer decided to build a series of additional HRRT scanners to try to improve the design (detector electronics, transmission source design, and shielding against out-of-FOV activity) and to eliminate problems (difficult detector

  7. Tomographic evaluation of a dual-head positron emission tomography system

    International Nuclear Information System (INIS)

    Efthimiou, N; Maistros, S; Tripolitis, X; Panayiotakis, G; Samartzis, A; Loudos, G

    2011-01-01

    In this paper we present the performance evaluation results, in the planar and tomographic modes, of a low-cost positron emission tomography camera dedicated to small-animal imaging. The system consists of two pixelated Lu 2 SiO 5 crystals, two Hamamatsu H8500 position sensitive photomultiplier tubes, fast amplification electronics and an FPGA-USB-based read-out system. The parameters that have been studied are (i) saturation as a function of the head distance and photon acceptance angle, (ii) effect of the number of projections and half or complete head's rotation, (iii) spatial resolution as a function of the head distance, (iv) spatial resolution as a function of acceptance angle, (v) system's sensitivity as a function of these parameters and (vi) performance in small mice imaging. Image reconstruction has been carried out using open source software developed by our group (QSPECT), which is designed mainly for SPECT imaging. The results indicate that the system has a linear response for activities up to at least 2 MBq, which are typical in small-animal imaging. Best tomographic spatial resolution was measured to be ∼2 mm. The system has been found suitable for imaging of small mice both in the planar and tomographic modes

  8. Theoretical exploration of the neural bases of behavioural disinhibition, apathy and executive dysfunction in preclinical Alzheimer's disease in people with Down's syndrome: potential involvement of multiple frontal-subcortical neuronal circuits.

    Science.gov (United States)

    Ball, S L; Holland, A J; Watson, P C; Huppert, F A

    2010-04-01

    Recent research has suggested a specific impairment in frontal-lobe functioning in the preclinical stages of Alzheimer's disease (AD) in people with Down's syndrome (DS), characterised by prominent changes in personality or behaviour. The aim of the current paper is to explore whether particular kinds of change (namely executive dysfunction (EDF), disinhibition and apathy), associated in the literature with disruption of different underlying frontal-subcortical circuits, are a) more or less frequently reported than others and b) related to poor performance on tasks involving different cognitive processes. Seventy-eight participants (mean age 47 years, range 36-72) with DS and mild to moderate intellectual disability (based on ICD-10 criteria), without a diagnosis of dementia of Alzheimer's type (DAT) or other psychiatric disorders, were selected from a larger sample of older adults with DS (n = 122). Dementia diagnosis was based on the CAMDEX informant interview, conducted with each participant's main carer. Informant-reported changes in personality/behaviour and memory were recorded. Participants were scored based on symptoms falling into three behavioural domains and completed five executive function (EF) tasks, six memory tasks (two of which also had a strong executive component) and the BPVS (as a measure of general intellectual ability). Multiple regression analyses were conducted to determine the degree to which the behavioural variables of 'EDF', 'disinhibition' and 'apathy', along with informant-reported memory decline and antidepressant medication use, predicted performance on the cognitive tasks (whilst controlling for the effects of age and general intellectual ability). Strikingly, disinhibited behaviour was reported for 95.7% of participants with one or more behavioural change (n = 47) compared to 57.4% with reported apathy and 36.2% with reported EDF. 'Disinhibition' score significantly predicted performance on three EF tasks (designed to measure

  9. Computed tomographic findings of hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Eun, Chung Kie [Kyung Hee University College of Medicine, Seoul (Korea, Republic of)

    1982-09-15

    It is well known that CT is very useful in the evaluation of hepatocellular carcinoma. The computed tomographic findings of 56 patients diagnosed as hepatocellular carcinoma were reviewed and analyzed. The results were as follows: 1. The male to female ratio was 3 : 1 and the age ranged from 31 to 73 years with average age of 54 years. 2. Alpha-fetoprotein was positive in 19 out of 38 cases (50%). HBsAg was positive in 8 out of 33 cases (24%). 3. All lesions were seen as areas of low density except 1 case (0%) of isodensity, and 40 cases (72%) appeared to be solitary while 15 (26%) were multifocal. The low density was homogenous in 13 cases (24%) and inhomogenous in 42 cases (76%), and 18 cases out of 42 cases inhomogenous low density showed peripheal and/or central nodular enhancement. The additional findings were contour changes in 37 cases (66%), metastasis in 35 cases (63%), splenomegaly in 23 cases (42%) and ascities in 22 cases (39%). 4. In postcontrast scans, 41 cases (80%) out of 51 cases showed the change of density after contrast infusion. The presence and extent of tumors were better seen after contrast infusion in 30 cases (59%), better seen before contrast infusion in 11 cases (21%) and no significant difference before and after contrast infusion in 10 cases (20%). 5. The sites of involved lobe were right lobe in 38 cases (68%), left lobe in 5 cases (9%) and both lobes in 13 cases (23%). 6. 35 cases (63%) showed evidence of metastasis to regional lymph nodes, organ or tissues.

  10. Computed tomographic findings of cerebral paragonimiasis

    International Nuclear Information System (INIS)

    Bae, Weon Tae; Jung, Min Ki; Kang, Heoung Keun; Chung, Hyon De

    1988-01-01

    Authors analyzed the computed tomographic (CT) findings of 19 cases pathologically and clinically proven cerebral paragonimiasis that were performed at Chonnam University Hospital from April 1983 through March 1987. The results were as follows: 1. Male to female ratio was 15:4 and the most prevalent age group was 3rd decade (7 cases). The common symptoms were epileptic seizure (16 cases) and headache (12 cases). 2. The multiplicity of cerebral paragonimiasis was 7 of 19 cases and the distributions of lesion were occipital (11 cases), temporal (6 cases), frontal (5 cases) and parietal (5 cases) lobe. 3. The calcification on CT scan were single (7 cases) or multiple (7 cases) and the shape of calcification were nodular (10 cases), soap babble of ring (8 cases), and stippled (6 cases). The pattern of contrast enhancement were ring (5 cases) or nodular (1 case), and along the basal cistern (1 case with arachnoiditis). 4. 12 out of 13 cases, had long clinical symptoms over 3 years with calcifications, could be analyzed according to Valentine's vascular territory; 6 cases in PCA territory, 3 in MCA and 3 in ACA. 5. CT findings were noted according to the duration of symptoms; 5 cases, had symptoms less than 1 year, showed abscess (5 cases) and arachnoiditis (1 case) with brain edema, mass effect, hydrocephalus and contrast enhancement but no calcification in all. One case, had symptom of 1 year and 2 months, showed partially calcified granulomatous lesion with perifocal edema and contrast enhancement, 13 cases, had symptoms over 3 years, showed multiple calcification with brain atrophy (10 cases), but no contrast enhancement in all cases.

  11. In vivo tomographic imaging with fluorescence and MRI using tumor-targeted dual-labeled nanoparticles

    Directory of Open Access Journals (Sweden)

    Zhang Y

    2013-12-01

    Full Text Available Yue Zhang,1 Bin Zhang,1 Fei Liu,1,2 Jianwen Luo,1,3 Jing Bai1 1Department of Biomedical Engineering, School of Medicine, 2Tsinghua-Peking Center for Life Sciences, 3Center for Biomedical Imaging Research, Tsinghua University, Beijing, People's Republic of China Abstract: Dual-modality imaging combines the complementary advantages of different modalities, and offers the prospect of improved preclinical research. The combination of fluorescence imaging and magnetic resonance imaging (MRI provides cross-validated information and direct comparison between these modalities. Here, we report on the application of a novel tumor-targeted, dual-labeled nanoparticle (NP, utilizing iron oxide as the MRI contrast agent and near infrared (NIR dye Cy5.5 as the fluorescent agent. Results of in vitro experiments verified the specificity of the NP to tumor cells. In vivo tumor targeting and uptake of the NPs in a mouse model were visualized by fluorescence and MR imaging collected at different time points. Quantitative analysis was carried out to evaluate the efficacy of MRI contrast enhancement. Furthermore, tomographic images were also acquired using both imaging modalities and cross-validated information of tumor location and size between these two modalities was revealed. The results demonstrate that the use of dual-labeled NPs can facilitate the dual-modal detection of tumors, information cross-validation, and direct comparison by combing fluorescence molecular tomography (FMT and MRI. Keywords: dual-modality, fluorescence molecular tomography (FMT, magnetic resonance imaging (MRI, nanoparticle

  12. Non-rigid registration of tomographic images with Fourier transforms

    International Nuclear Information System (INIS)

    Osorio, Ar; Isoardi, Ra; Mato, G

    2007-01-01

    Spatial image registration of deformable body parts such as thorax and abdomen has important medical applications, but at the same time, it represents an important computational challenge. In this work we propose an automatic algorithm to perform non-rigid registration of tomographic images using a non-rigid model based on Fourier transforms. As a measure of similarity, we use the correlation coefficient, finding that the optimal order of the transformation is n = 3 (36 parameters). We apply this method to a digital phantom and to 7 pairs of patient images corresponding to clinical CT scans. The preliminary results indicate a fairly good agreement according to medical experts, with an average registration error of 2 mm for the case of clinical images. For 2D images (dimensions 512x512), the average running time for the algorithm is 15 seconds using a standard personal computer. Summarizing, we find that intra-modality registration of the abdomen can be achieved with acceptable accuracy for slight deformations and can be extended to 3D with a reasonable execution time

  13. Cardiac imaging systems and methods employing computerized tomographic scanning

    International Nuclear Information System (INIS)

    Richey, J.B.; Wake, R.H.; Walters, R.G.; Hunt, W.F.; Cool, S.L.

    1980-01-01

    The invention relates to cardiac imaging systems and methods employing computerised tomographic scanning. Apparatus is described which allows an image of the radiation attenuation of the heart at a desired phase of the cardiac cycle. The patients ECG signal can be used in a transverse-and-rotate type CT scanner as a time base, so that the beam reaches the heart at a desired phase of the cardiac cycle, or, in a purely rotational-type CT scanner continuously generated scan data is only stored for corresponding phases of successive cardiac cycles. Alternatively, gating of the beams themselves by shuttering or switching the power supply can be controlled by the ECG signal. A pacemaker is used to stabilize the cardiac period. Also used is a system for recognising unacceptable variations in the cardiac period and discarding corresponding scan data. In a transverse-and-rotate type fan-beam CT scanner, the effective beam width is narrowed to reduce the duration of the traverse of the heart. (U.K.)

  14. Random signal tomographical analysis of two-phase flow

    International Nuclear Information System (INIS)

    Han, P.; Wesser, U.

    1990-01-01

    This paper reports on radiation tomography which is a useful tool for studying the internal structures of two-phase flow. However, general tomography analysis gives only time-averaged results, hence much information is lost. As a result, it is sometimes difficult to identify the flow regime; for example, the time-averaged picture does not significantly change as an annual flow develops from a slug flow. A two-phase flow diagnostic technique based on random signal tomographical analysis is developed. It extracts more information by studying the statistical variation of the measured signal with time. Local statistical parameters, including mean value, variance, skewness and flatness etc., are reconstructed from the information obtained by a general tomography technique. More important information are provided by the results. Not only the void fraction can be easily calculated, but also the flow pattern can be identified more objectively and more accurately. The experimental setup is introduced. It consisted of a two-phase flow loop, an X-ray system, a fan-like five-beam detector system and a signal acquisition and processing system. In the experiment, for both horizontal and vertical test sections (aluminum and steel tube with Di/Do = 40/45 mm), different flow situations are realized by independently adjusting air and water mass flow. Through a glass tube connected with the test section, some typical flow patterns are visualized and used for comparing with the reconstruction results

  15. Quantitative analysis of normal thallium-201 tomographic studies

    International Nuclear Information System (INIS)

    Eisner, R.L.; Gober, A.; Cerqueira, M.

    1985-01-01

    To determine the normal (nl) distribution of Tl-201 uptake post exercise (EX) and at redistribution (RD) and nl washout, Tl-201 rotational tomographic (tomo) studies were performed in 40 subjects: 16 angiographic (angio) nls and 24 nl volunteers (12 from Emory and 12 from Yale). Oblique angle short axis slices were subjected to maximal count circumferential profile analysis. Data were displayed as a ''bullseye'' functional map with the apex at the center and base at the periphery. The bullseye was not uniform in all regions because of the variable effects of attenuation and resolution at different view angles. In all studies, the septum: lateral wall ratio was 1.0 in males and approximately equal to 1.0 in females. This occurred predominantly because of anterior defects due to breast soft tissue attenuation. EX and RD bullseyes were similar. Using a bi-exponential model for Tl kinetics, 4 hour normalized washout ranged 49-54% in each group and showed minimal variation between walls throughout the bullseye. Thus, there are well defined variations in Tl-201 uptake in the nl myocardium which must be taken into consideration when analyzing pt data. Because of these defects and the lack of adequate methods for attenuation correction, quantitative analysis of Tl-201 studies must include direct comparison with gender-matched nl data sets

  16. Line-scanning tomographic optical microscope with isotropic transfer function

    International Nuclear Information System (INIS)

    Gajdátsy, Gábor; Dudás, László; Erdélyi, Miklós; Szabó, Gábor

    2010-01-01

    An imaging method and optical system, referred to as a line-scanning tomographic optical microscope (LSTOM) using a combination of line-scanning technique and CT reconstruction principle, is proposed and studied theoretically and experimentally. In our implementation a narrow focus line is scanned over the sample and the reflected light is measured in a confocal arrangement. One such scan is equivalent to a transverse projection in tomography. Repeating the scanning procedure in several directions, a number of transverse projections are recorded from which the image can be obtained using conventional CT reconstruction algorithms. The resolution of the image is independent of the spatial dimensions and structure of the applied detector; furthermore, the transfer function of the system is isotropic. The imaging performance of the implemented confocal LSTOM was compared with a point-scanning confocal microscope, based on recorded images. These images demonstrate that the resolution of the confocal LSTOM exceeds (by 15%) the resolution limit of a point-scanning confocal microscope

  17. Synchronized multiartifact reduction with tomographic reconstruction (SMART-RECON): A statistical model based iterative image reconstruction method to eliminate limited-view artifacts and to mitigate the temporal-average artifacts in time-resolved CT.

    Science.gov (United States)

    Chen, Guang-Hong; Li, Yinsheng

    2015-08-01

    In x-ray computed tomography (CT), a violation of the Tuy data sufficiency condition leads to limited-view artifacts. In some applications, it is desirable to use data corresponding to a narrow temporal window to reconstruct images with reduced temporal-average artifacts. However, the need to reduce temporal-average artifacts in practice may result in a violation of the Tuy condition and thus undesirable limited-view artifacts. In this paper, the authors present a new iterative reconstruction method, synchronized multiartifact reduction with tomographic reconstruction (SMART-RECON), to eliminate limited-view artifacts using data acquired within an ultranarrow temporal window that severely violates the Tuy condition. In time-resolved contrast enhanced CT acquisitions, image contrast dynamically changes during data acquisition. Each image reconstructed from data acquired in a given temporal window represents one time frame and can be denoted as an image vector. Conventionally, each individual time frame is reconstructed independently. In this paper, all image frames are grouped into a spatial-temporal image matrix and are reconstructed together. Rather than the spatial and/or temporal smoothing regularizers commonly used in iterative image reconstruction, the nuclear norm of the spatial-temporal image matrix is used in SMART-RECON to regularize the reconstruction of all image time frames. This regularizer exploits the low-dimensional structure of the spatial-temporal image matrix to mitigate limited-view artifacts when an ultranarrow temporal window is desired in some applications to reduce temporal-average artifacts. Both numerical simulations in two dimensional image slices with known ground truth and in vivo human subject data acquired in a contrast enhanced cone beam CT exam have been used to validate the proposed SMART-RECON algorithm and to demonstrate the initial performance of the algorithm. Reconstruction errors and temporal fidelity of the reconstructed

  18. Correction of ring artifacts in X-ray tomographic images

    DEFF Research Database (Denmark)

    Lyckegaard, Allan; Johnson, G.; Tafforeau, P.

    2011-01-01

    Ring artifacts are systematic intensity distortions located on concentric circles in reconstructed tomographic X-ray images. When using X-ray tomography to study for instance low-contrast grain boundaries in metals it is crucial to correct for the ring artifacts in the images as they may have...... the same intensity level as the grain boundaries and thus make it impossible to perform grain segmentation. This paper describes an implementation of a method for correcting the ring artifacts in tomographic X-ray images of simple objects such as metal samples where the object and the background...... are separable. The method is implemented in Matlab, it works with very little user interaction and may run in parallel on a cluster if applied to a whole stack of images. The strength and robustness of the method implemented will be demonstrated on three tomographic X-ray data sets: a mono-phase β...

  19. Radiosynoviorthesis. Clinical and preclinical dosimetry

    International Nuclear Information System (INIS)

    Torres Berdeguez, Mirta B; Ayra Pardo, Fernando E

    2006-01-01

    Accurate calculation of internal dose estimates in the Radiosynoviorthesis treatment requires several steps of analysis. The use of animal models (rabbits) to predict human kinetics and dosimetry is an essential first step in the evaluation of new radiocolloids, but involves many uncertainties. There is no gold standard method for extrapolating animal data to humans. Nonetheless, human dose estimates based on animal data are considered to be reasonable approximations to be used for proceeding with dose estimates based on human data, which are ultimately used to assess the safety and efficacy evaluations of radiopharmaceuticals, and continues to be an important element in the radiopharmaceutical approval process. The obtained absorbed dose profiles versus synovial tissue, bone and articular cartilage depth will permit the specialist to prescribe the adequate dose of radionuclide to treat rheumatoid arthritis in medium and large joints without expose the healthy structures of the synovial joint to an excessive and unnecessary irradiation risk, eliminating the fixed dose and fixed radionuclides for each joints (Author)

  20. A prototype high-resolution animal positron tomograph with avalanche photodiode arrays and LSO crystals

    International Nuclear Information System (INIS)

    Ziegler, S.I.; Pichler, B.J.; Rafecas, M.; Schwaiger, M.

    2001-01-01

    To fully utilize positron emission tomography (PET) as a non-invasive tool for tissue characterization, dedicated instrumentation is being developed which is specially suited for imaging mice and rats. Semiconductor detectors, such as avalanche photodiodes (APDs), may offer an alternative to photomultiplier tubes for the readout of scintillation crystals. Since the scintillation characteristics of lutetium oxyorthosilicate (LSO) are well matched to APDs, the combination of LSO and APDs seems favourable, and the goal of this study was to build a positron tomograph with LSO-APD modules to prove the feasibility of such an approach. A prototype PET scanner based on APD readout of small, individual LSO crystals was developed for tracer studies in mice and rats. The tomograph consists of two sectors (86 mm distance), each comprising three LSO-APD modules, which can be rotated for the acquisition of complete projections. In each module, small LSO crystals (3.7 x 3.7 x 12 mm 3 ) are individually coupled to one channel within matrices containing 2 x 8 square APDs (2.6 x 2.6 mm 2 sensitive area per channel). The list-mode data are reconstructed with a penalized weighted least squares algorithm which includes the spatially dependent line spread function of the tomograph. Basic performance parameters were measured with phantoms and first experiments with rats and mice were conducted to introduce this methodology for biomedical imaging. The reconstructed field of view covers 68 mm, which is 80% of the total detector diameter. Image resolution was shown to be 2.4 mm within the whole reconstructed field of view. Using a lower energy threshold of 450 keV, the system sensitivity was 350 Hz/MBq for a line source in air in the centre of the field of view. In a water-filled cylinder of 4.6 cm diameter, the scatter fraction at the centre of the field of view was 16% (450 keV threshold). The count rate was linear up to 700 coincidence counts per second. In vivo studies of anaesthetized

  1. Modeling the Western Diet for Preclinical Investigations.

    Science.gov (United States)

    Hintze, Korry J; Benninghoff, Abby D; Cho, Clara E; Ward, Robert E

    2018-05-01

    Rodent models have been invaluable for biomedical research. Preclinical investigations with rodents allow researchers to investigate diseases by using study designs that are not suitable for human subjects. The primary criticism of preclinical animal models is that results are not always translatable to humans. Some of this lack of translation is due to inherent differences between species. However, rodent models have been refined over time, and translatability to humans has improved. Transgenic animals have greatly aided our understanding of interactions between genes and disease and have narrowed the translation gap between humans and model animals. Despite the technological innovations of animal models through advances in genetics, relatively little attention has been given to animal diets. Namely, developing diets that replicate what humans eat will help make animal models more relevant to human populations. This review focuses on commonly used rodent diets that are used to emulate the Western dietary pattern in preclinical studies of obesity and type 2 diabetes, nonalcoholic liver disease, maternal nutrition, and colorectal cancer.

  2. Collaborative learning in pre-clinical dental hygiene education.

    Science.gov (United States)

    Mueller-Joseph, Laura J; Nappo-Dattoma, Luisa

    2013-04-01

    Dental hygiene education continues to move beyond mastery of content material and skill development to learning concepts that promote critical-thinking and problem-solving skills. The purpose of this research was to evaluate the effectiveness of collaborative learning and determine the growth in intellectual development of 54 first-year dental hygiene students. The control group used traditional pre-clinical teaching and the experimental group used collaborative pedagogy for instrument introduction. All students were subjected to a post-test evaluating their ability to apply the principles of instrumentation. Intellectual development was determined using pre- and post-tests based on the Perry Scheme of Intellectual Development. Student attitudes were assessed using daily Classroom Assessment Activities and an end-of-semester departmental course evaluation. Findings indicated no significant difference between collaborative learning and traditional learning in achieving pre-clinical competence as evidenced by the students' ability to apply the principles of instrumentation. Advancement in intellectual development did not differ significantly between groups. Value added benefits of a collaborative learning environment as identified by the evaluation of student attitudes included decreased student reliance on authority, recognition of peers as legitimate sources of learning and increased self-confidence. A significant difference in student responses to daily classroom assessments was evident on the 5 days a collaborative learning environment was employed. Dental hygiene students involved in a pre-clinical collaborative learning environment are more responsible for their own learning and tend to have a more positive attitude toward the subject matter. Future studies evaluating collaborative learning in clinical dental hygiene education need to investigate the cost/benefit ratio of the value added outcomes of collaborative learning.

  3. Generalized Row-Action Methods for Tomographic Imaging

    DEFF Research Database (Denmark)

    Andersen, Martin Skovgaard; Hansen, Per Christian

    2014-01-01

    Row-action methods play an important role in tomographic image reconstruction. Many such methods can be viewed as incremental gradient methods for minimizing a sum of a large number of convex functions, and despite their relatively poor global rate of convergence, these methods often exhibit fast...... initial convergence which is desirable in applications where a low-accuracy solution is acceptable. In this paper, we propose relaxed variants of a class of incremental proximal gradient methods, and these variants generalize many existing row-action methods for tomographic imaging. Moreover, they allow...

  4. Subjective memory complaints in preclinical autosomal dominant Alzheimer disease.

    Science.gov (United States)

    Norton, Daniel J; Amariglio, Rebecca; Protas, Hillary; Chen, Kewei; Aguirre-Acevedo, Daniel C; Pulsifer, Brendan; Castrillon, Gabriel; Tirado, Victoria; Munoz, Claudia; Tariot, Pierre; Langbaum, Jessica B; Reiman, Eric M; Lopera, Francisco; Sperling, Reisa A; Quiroz, Yakeel T

    2017-10-03

    To cross-sectionally study subjective memory complaints (SMC) in autosomal dominant Alzheimer disease (ADAD). We examined self-reported and study partner-based SMC in 52 young, cognitively unimpaired individuals from a Colombian kindred with early-onset ADAD. Twenty-six carried the PSEN-1 E280A mutation, averaging 7 years of age younger than the kindred's expected clinical onset. Twenty-six were age-matched noncarriers. Participants also underwent structural MRI and cognitive testing. Self-reported SMC were greater in carriers than noncarriers ( p = 0.02). Study partner-based SMC did not differ between groups ( p = 0.21), but in carriers increased with age ( r = 0.66, p < 0.001) and decreased with hippocampal volume ( r = -0.35, p = 0.08). Cognitively unimpaired PSEN-1 carriers have elevated SMC. Self-reported SMC may be a relatively early indicator of preclinical AD, while partner- reported SMC increases later in preclinical AD, closer to clinical onset. © 2017 American Academy of Neurology.

  5. Development of computational small animal models and their applications in preclinical imaging and therapy research

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Tianwu [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva 4 CH-1211 (Switzerland); Zaidi, Habib, E-mail: habib.zaidi@hcuge.ch [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva 4 CH-1211 (Switzerland); Geneva Neuroscience Center, Geneva University, Geneva CH-1205 (Switzerland); Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen 9700 RB (Netherlands)

    2016-01-15

    The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future.

  6. Development of computational small animal models and their applications in preclinical imaging and therapy research.

    Science.gov (United States)

    Xie, Tianwu; Zaidi, Habib

    2016-01-01

    The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future.

  7. Development of computational small animal models and their applications in preclinical imaging and therapy research

    International Nuclear Information System (INIS)

    Xie, Tianwu; Zaidi, Habib

    2016-01-01

    The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future

  8. Tomographic reconstruction of atmospheric volumes from infrared limb-imager measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ungermann, Joern

    2011-08-12

    State-of-the art nadir and limb-sounders, but also in situ measurements, do not offer the capability to highly resolve the atmosphere in all three dimensions. This leaves an observational gap with respect to small-scale structures that arise frequently in the atmosphere and that still lack a quantitative understanding. For instance, filaments and tropopause folds in the upper troposphere and lower stratosphere (UTLS) are crucial for its composition and variability. One way to achieve a highly resolved three-dimensional (3-D) picture of the atmosphere is the tomographic evaluation of limb-imager measurements. This thesis presents a methodology for the tomographic reconstruction of atmospheric constituents. To be able to deal with the large increase of observations and unknowns compared to conventional retrievals, great care is taken to reduce memory consumption and processing time. This method is used to evaluate the performance of two upcoming infrared limb-imager instruments and to prepare their missions. The first examined instrument is the infrared limb-imager on board of PREMIER (Process Exploration through Measurements of Infrared and millimetrewave Emitted Radiation), one of three remaining candidates for ESA's 7th Earth Explorer mission. Scientific goals of PREMIER are, among others, the examination of gravity waves and the quantification of processes controlling atmospheric composition in the UTLS, a region of particular importance for climate change. Simulations based on the performance requirements of this instrument deliver a vertical resolution that is slightly better than its vertical field-of-view (about 0.75 km) and a horizontal resolution of {approx}25km x 70 km. Non-linear end-to-end simulations for various gravity wave patterns demonstrate that the high 3-D resolution of PREMIER considerably extends the range of detectable gravity waves in terms of horizontal and vertical wavelength compared to previous observations. The second examined

  9. Tomographic reconstruction of atmospheric volumes from infrared limb-imager measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ungermann, Joern

    2011-08-12

    State-of-the art nadir and limb-sounders, but also in situ measurements, do not offer the capability to highly resolve the atmosphere in all three dimensions. This leaves an observational gap with respect to small-scale structures that arise frequently in the atmosphere and that still lack a quantitative understanding. For instance, filaments and tropopause folds in the upper troposphere and lower stratosphere (UTLS) are crucial for its composition and variability. One way to achieve a highly resolved three-dimensional (3-D) picture of the atmosphere is the tomographic evaluation of limb-imager measurements. This thesis presents a methodology for the tomographic reconstruction of atmospheric constituents. To be able to deal with the large increase of observations and unknowns compared to conventional retrievals, great care is taken to reduce memory consumption and processing time. This method is used to evaluate the performance of two upcoming infrared limb-imager instruments and to prepare their missions. The first examined instrument is the infrared limb-imager on board of PREMIER (Process Exploration through Measurements of Infrared and millimetrewave Emitted Radiation), one of three remaining candidates for ESA's 7th Earth Explorer mission. Scientific goals of PREMIER are, among others, the examination of gravity waves and the quantification of processes controlling atmospheric composition in the UTLS, a region of particular importance for climate change. Simulations based on the performance requirements of this instrument deliver a vertical resolution that is slightly better than its vertical field-of-view (about 0.75 km) and a horizontal resolution of {approx}25km x 70 km. Non-linear end-to-end simulations for various gravity wave patterns demonstrate that the high 3-D resolution of PREMIER considerably extends the range of detectable gravity waves in terms of horizontal and vertical wavelength compared to previous observations. The second examined instrument

  10. An evolutionary algorithm for tomographic reconstructions in limited data sets problems

    International Nuclear Information System (INIS)

    Turcanu, Catrinel; Craciunescu, Teddy

    2000-01-01

    The paper proposes a new method for tomographic reconstructions. Unlike nuclear medicine applications, in physical science problems we are often confronted with limited data sets: constraints in the number of projections or limited angle views. The problem of image reconstruction from projections may be considered as a problem of finding an image (solution) having projections that match the experimental ones. In our approach, we choose a statistical correlation coefficient to evaluate the fitness of any potential solution. The optimization process is carried out by an evolutionary algorithm. Our algorithm has some problem-oriented characteristics. One of them is that a chromosome, representing a potential solution, is not linear but coded as a matrix of pixels corresponding to a two-dimensional image. This kind of internal representation reflects the genuine manifestation and slight differences between two points situated in the original problem space give rise to similar differences once they become coded. Another particular feature is a newly built crossover operator: the grid-based crossover, suitable for high dimension two-dimensional chromosomes. Except for the population size and the dimension of the cutting grid for the grid-based crossover, all the other parameters of the algorithm are independent of the geometry of the tomographic reconstruction. The performances of the method are evaluated in comparison with a traditional tomographic method, based on the maximization of the entropy of the image, that proved to work well with limited data sets. The test phantom is typical for an application with limited data sets: the determination of the neutron energy spectra with time resolution in case of short-pulsed neutron emission. The qualitative judgement and also the quantitative one, based on some figures of merit, point out that the proposed method ensures an improved reconstruction of shapes, sizes and resolution in the image, even in the presence of noise

  11. New method to analyze internal disruptions with tomographic reconstructions

    Energy Technology Data Exchange (ETDEWEB)

    Tanzi, C.P. [EURATOM-FOM Association, FOM-Instituut voor Plasmafysica Rijnhuizen, P.O. BOX 1207, 3430 BE Nieuwegein (The Netherlands); de Blank, H.J. [Max-Planck-Institut fuer Plasmaphysik, EURATOM-IPP Association, 85740 Garching (Germany)

    1997-03-01

    Sawtooth crashes have been investigated on the Rijnhuizen Tokamak Project (RTP) [N. J. Lopes Cardozo {ital et al.}, {ital Proceedings of the 14th International Conference on Plasma Physics and Controlled Nuclear Fusion Research}, W{umlt u}rzburg, 1992 (International Atomic Energy Agency, Vienna, 1993), Vol. 1, p. 271]. Internal disruptions in tokamak plasmas often exhibit an m=1 poloidal mode structure prior to the collapse which can be clearly identified by means of multicamera soft x-ray diagnostics. In this paper tomographic reconstructions of such m=1 modes are analyzed with a new method, based on magnetohydrodynamic (MHD) invariants computed from the two-dimensional emissivity profiles, which quantifies the amount of profile flattening not only after the crash but also during the precursor oscillations. The results are interpreted by comparing them with two models which simulate the measurements of the m=1 redistribution of soft x-ray emissivity prior to the sawtooth crash. One model is based on the magnetic reconnection model of Kadomtsev. The other involves ideal MHD motion only. In cases where differences in magnetic topology between the two models cannot be seen in the tomograms, the analysis of profile flattening has an advantage. The analysis shows that in RTP the clearly observed m=1 displacement of some sawteeth requires the presence of convective ideal MHD motion, whereas other precursors are consistent with magnetic reconnection of up to 75{percent} of the magnetic flux within the q=1 surface. The possibility of ideal interchange combined with enhanced cross-field transport is not excluded. {copyright} {ital 1997 American Institute of Physics.}

  12. New method to analyze internal disruptions with tomographic reconstructions

    International Nuclear Information System (INIS)

    Tanzi, C.P.; de Blank, H.J.

    1997-01-01

    Sawtooth crashes have been investigated on the Rijnhuizen Tokamak Project (RTP) [N. J. Lopes Cardozo et al., Proceedings of the 14th International Conference on Plasma Physics and Controlled Nuclear Fusion Research, Wuerzburg, 1992 (International Atomic Energy Agency, Vienna, 1993), Vol. 1, p. 271]. Internal disruptions in tokamak plasmas often exhibit an m=1 poloidal mode structure prior to the collapse which can be clearly identified by means of multicamera soft x-ray diagnostics. In this paper tomographic reconstructions of such m=1 modes are analyzed with a new method, based on magnetohydrodynamic (MHD) invariants computed from the two-dimensional emissivity profiles, which quantifies the amount of profile flattening not only after the crash but also during the precursor oscillations. The results are interpreted by comparing them with two models which simulate the measurements of the m=1 redistribution of soft x-ray emissivity prior to the sawtooth crash. One model is based on the magnetic reconnection model of Kadomtsev. The other involves ideal MHD motion only. In cases where differences in magnetic topology between the two models cannot be seen in the tomograms, the analysis of profile flattening has an advantage. The analysis shows that in RTP the clearly observed m=1 displacement of some sawteeth requires the presence of convective ideal MHD motion, whereas other precursors are consistent with magnetic reconnection of up to 75% of the magnetic flux within the q=1 surface. The possibility of ideal interchange combined with enhanced cross-field transport is not excluded. copyright 1997 American Institute of Physics

  13. Tomographic spectral imaging: microanalysis in 3D

    International Nuclear Information System (INIS)

    Kotula, P.G.; Keenan, M.R.; Michael, J.R.

    2003-01-01

    Full text: Spectral imaging, where a series of complete x-ray spectra are typically collected from a 2D area, holds great promise for comprehensive near-surface microanalysis. There are however numerous microanalysis problems where 3D chemical information is needed as well. In the SEM, some sort of sectioning (either mechanical or with a focused ion beam (FIB) tool) followed by x-ray mapping has, in the past, been utilized in an attempt to perform 3D microanalysis. Reliance on simple mapping has the potential to miss important chemical features as well as misidentify others. In this paper we will describe the acquisition of serial-section tomographic spectral images (TSI) with a dual-beam FIB/SEM equipped with an EDS system. We will also describe the application of a modified version of our multivariate statistical analysis algorithms to TSIs. Serial sectioning was performed with a FEI DB-235 FIB/SEM. Firstly, the specimen normal was tilted to the optic axis of the FIB column and a trench was milled into the surface of the specimen. A second trench was then milled perpendicular to the first to provide visibility of the entire analysis surface to the x-ray detector. In addition, several fiducial markers were milled into the surface to allow for alignment from slice to slice. The electron column is at an angle of 52 deg to the ion column so the electron beam can 'see' the analysis surface milled by the FIB with no additional specimen tilting or rotation. Likewise the x-ray detector is at a radial angle of 45 deg to the plane of the electron and ion columns (about the electron column) and a take-off-angle of 35 deg with respect to an untilted specimen so it can 'see' the analysis surface as well with no additional sample tilting or rotation. Spectral images were acquired from regions 40 μm wide and 20μm deep for each slice. Approximately 1μm/slice was milled and 10-12 total slices were cut. Spectral images were acquired with a Thermo NORAN Vantage (Digital imaging

  14. A review of US anthropometric reference data (1971-2000) with comparisons to both stylized and tomographic anatomic models

    International Nuclear Information System (INIS)

    Huh, C; Bolch, W E

    2003-01-01

    Two classes of anatomic models currently exist for use in both radiation protection and radiation dose reconstruction: stylized mathematical models and tomographic voxel models. The former utilize 3D surface equations to represent internal organ structure and external body shape, while the latter are based on segmented CT or MR images of a single individual. While tomographic models are clearly more anthropomorphic than stylized models, a given model's characterization as being anthropometric is dependent upon the reference human to which the model is compared. In the present study, data on total body mass, standing/sitting heights and body mass index are collected and reviewed for the US population covering the time interval from 1971 to 2000. These same anthropometric parameters are then assembled for the ORNL series of stylized models, the GSF series of tomographic models (Golem, Helga, Donna, etc), the adult male Zubal tomographic model and the UF newborn tomographic model. The stylized ORNL models of the adult male and female are found to be fairly representative of present-day average US males and females, respectively, in terms of both standing and sitting heights for ages between 20 and 60-80 years. While the ORNL adult male model provides a reasonably close match to the total body mass of the average US 21-year-old male (within ∼5%), present-day 40-year-old males have an average total body mass that is ∼16% higher. For radiation protection purposes, the use of the larger 73.7 kg adult ORNL stylized hermaphrodite model provides a much closer representation of average present-day US females at ages ranging from 20 to 70 years. In terms of the adult tomographic models from the GSF series, only Donna (40-year-old F) closely matches her age-matched US counterpart in terms of average body mass. Regarding standing heights, the better matches to US age-correlated averages belong to Irene (32-year-old F) for the females and Golem (38-year-old M) for the males

  15. Reproducibility of preclinical animal research improves with heterogeneity of study samples

    Science.gov (United States)

    Vogt, Lucile; Sena, Emily S.; Würbel, Hanno

    2018-01-01

    Single-laboratory studies conducted under highly standardized conditions are the gold standard in preclinical animal research. Using simulations based on 440 preclinical studies across 13 different interventions in animal models of stroke, myocardial infarction, and breast cancer, we compared the accuracy of effect size estimates between single-laboratory and multi-laboratory study designs. Single-laboratory studies generally failed to predict effect size accurately, and larger sample sizes rendered effect size estimates even less accurate. By contrast, multi-laboratory designs including as few as 2 to 4 laboratories increased coverage probability by up to 42 percentage points without a need for larger sample sizes. These findings demonstrate that within-study standardization is a major cause of poor reproducibility. More representative study samples are required to improve the external validity and reproducibility of preclinical animal research and to prevent wasting animals and resources for inconclusive research. PMID:29470495

  16. Design and applications of Computed Industrial Tomographic Imaging System (CITIS)

    Energy Technology Data Exchange (ETDEWEB)

    Ramakrishna, G S; Kumar, Umesh; Datta, S S [Bhabha Atomic Research Centre, Bombay (India). Isotope Div.

    1994-12-31

    This paper highlights the design and development of a prototype Computed Tomographic (CT) imaging system and its software for image reconstruction, simulation and display. It also describes results obtained with several test specimens including Dhruva reactor uranium fuel assembly and possibility of using neutrons as well as high energy x-rays in computed tomography. 5 refs., 4 figs.

  17. Computer tomographic detection of an intraspinal arachnoidal cyst

    Energy Technology Data Exchange (ETDEWEB)

    Kuckein, D; Walter, K; Paal, G

    1981-03-01

    A 46 year old female patient who after 3-4 weeks of influenza suffered from strong headaches, vomiting and rotatory vertigo was subjected to a myelograph and then to a computerized tomographic investigation due to suspect cerebrospinal fluid. The computerized tomography is better than the myelography in diagnosing intraspinal arachnoidal cysts, however this should be preceded by most accurate possible segment location.

  18. Comparison of the practical diagnostic value of different tomographic movements

    International Nuclear Information System (INIS)

    Laehde, S.; Vuoria, P.

    1977-01-01

    The practical results of linear and circular tomography with angles of 6, 20, 30 and 45 degrees and spiral tomography were compared. The spiral proved to be suitable as a tomographic movement for different purposes. In zonography, circular movement with 6 degrees of deviation proved suitable. The linear movement presented no advantages when compared with the multidirectional movements. ( orig.) [de

  19. Computed tomographic findings in manifesting carriers of Duchenne muscular dystrophy

    NARCIS (Netherlands)

    de Visser, M.; Verbeeten, B.

    1985-01-01

    Clinical and computed tomographic (CT) findings in 3 manifesting carriers of Duchenne muscular dystrophy are reported. CT proved to be an important adjunct to the clinical examination: in all our 3 cases a decrease in density was found in various non-paretic muscles

  20. Tomographic Particle Image Velocimetry using Smartphones and Colored Shadows

    KAUST Repository

    Aguirre-Pablo, Andres A.; Alarfaj, Meshal K.; Li, Erqiang; Hernandez Sanchez, Jose Federico; Thoroddsen, Sigurdur T

    2017-01-01

    We demonstrate the viability of using four low-cost smartphone cameras to perform Tomographic PIV. We use colored shadows to imprint two or three different time-steps on the same image. The back-lighting is accomplished with three sets

  1. Computerized tomographic findings in children with head trauma in ...

    African Journals Online (AJOL)

    Objective: To describe the computerized tomographic findings in children with head trauma who presented at the University of Benin Teaching Hospital, Benin City, Nigeria. Methods: It is a retrospective review of patients aged 0 – 15 years with suspected intracranial injury (ICI) following head trauma, who presented for CT ...

  2. Left ventricular remodeling in preclinical experimental mitral regurgitation of dogs.

    Science.gov (United States)

    Dillon, A Ray; Dell'Italia, Louis J; Tillson, Michael; Killingsworth, Cheryl; Denney, Thomas; Hathcock, John; Botzman, Logan

    2012-03-01

    Dogs with experimental mitral regurgitation (MR) provide insights into the left ventricular remodeling in preclinical MR. The early preclinical left ventricular (LV) changes after mitral regurgitation represent progressive dysfunctional remodeling, in that no compensatory response returns the functional stroke volume (SV) to normal even as total SV increases. The gradual disease progression leads to mitral annulus stretch and enlargement of the regurgitant orifice, further increasing the regurgitant volume. Remodeling with loss of collagen weave and extracellular matrix (ECM) is accompanied by stretching and hypertrophy of the cross-sectional area and length of the cardiomyocyte. Isolated ventricular cardiomyocytes demonstrate dysfunction based on decreased cell shortening and reduced intracellular calcium transients before chamber enlargement or decreases in contractility in the whole heart can be clinically appreciated. The genetic response to increased end-diastolic pressure is down-regulation of genes associated with support of the collagen and ECM and up-regulation of genes associated with matrix remodeling. Experiments have not demonstrated any beneficial effects on remodeling from treatments that decrease afterload via blocking the renin-angiotensin system (RAS). Beta-1 receptor blockade and chymase inhibition have altered the progression of the LV remodeling and have supported cardiomyocyte function. The geometry of the LV during the remodeling provides insight into the importance of regional differences in responses to wall stress. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. A tomographic test of cosmological principle using the JLA compilation of type Ia supernovae

    Science.gov (United States)

    Chang, Zhe; Lin, Hai-Nan; Sang, Yu; Wang, Sai

    2018-05-01

    We test the cosmological principle by fitting a dipolar modulation of distance modulus and searching for an evolution of this modulation with respect to cosmological redshift. Based on a redshift tomographic method, we divide the Joint Light-curve Analysis compilation of supernovae of type Ia into different redshift bins, and employ a Markov-Chain Monte-Carlo method to infer the anisotropic amplitude and direction in each redshift bin. However, we do not find any significant deviations from the cosmological principle, and the anisotropic amplitude is stringently constrained to be less than a few thousandths at 95% confidence level.

  4. Tomographic anthropomorphic models. Pt. 4. Organ doses for adults due to idealized external photon exposures

    CERN Document Server

    Zankl, M; Petoussi-Henss, N; Regulla, D

    2002-01-01

    The present report contains extensive tables and figures of conversion coefficients of organ and tissue equivalent dose, normalised to air kerma free in air for voxel anthropomorphic phantoms and for standard geometries of external photon radiation, estimated with Monte Carlo techniques. Four realistic adult voxel phantoms were used for the calculations, based on computed tomographic data of real people: three male phantoms, two of them being of average size, one representing a big man, and one female phantom of a tall and somewhat over weighted woman.

  5. Tomographic anthropomorphic models. Pt. 4. Organ doses for adults due to idealized external photon exposures

    International Nuclear Information System (INIS)

    Zankl, M.; Petoussi-Henss, N.; Fill, U.; Regulla, D.

    2002-01-01

    The present report contains extensive tables and figures of conversion coefficients of organ and tissue equivalent dose, normalised to air kerma free in air for voxel anthropomorphic phantoms and for standard geometries of external photon radiation, estimated with Monte Carlo techniques. Four realistic adult voxel phantoms were used for the calculations, based on computed tomographic data of real people: three male phantoms, two of them being of average size, one representing a big man, and one female phantom of a tall and somewhat over weighted woman. (orig.)

  6. The computed tomographic appearance of cerebral cysticercosis in adults and children

    International Nuclear Information System (INIS)

    Byrd, S.E.; Locke, G.E.; Biggers, S.; Percy, A.K.

    1982-01-01

    The computed tomographic (CT) scans of 45 patients (30 adults, 15 children) with cerebral cysticercosis were reviewed. These patients had undergone complete diagnostic evaluations including skin tests, laboratory tests, plain skull radiography, radionuclide brain scanning, CT, and cerebral angiography. All of these tests were unrewarding except CT and the indirect hemagglutination tests on the serum. A classification of cerebral cysticercosis based on the location of the lesions in the brain and the CT appearance was developed. Cerebral cysticercosis can be diagnosed by CT findings when there is also a history of seizures and of the patient having lived in an area where the disease is endemic

  7. A system dedicated to the viewing and handling of tomographic images obtained by magnetic resonance

    International Nuclear Information System (INIS)

    Slaets, Joan F.W.; Almeida, Lirio O.B.; Traina, Agma J.M.

    1992-01-01

    The present work describes the development of a dedicated system to be used in visualization and manipulation of a MR images. The graphics environment as well as the tool kit were developed for the dedicated TMS34010 based hardware. The developed software offers a compact kernel with primitives to support the creation and manipulation windows and menus directly in 'C' language. This work is fundamental for the implementation of a user friendly interface build to operate and visualize tomographic images. This tools are essential for the selection an archiving of images planes as used in clinical applications. (author)

  8. Automating the segmentation of medical images for the production of voxel tomographic computational models

    International Nuclear Information System (INIS)

    Caon, M.

    2001-01-01

    Radiation dosimetry for the diagnostic medical imaging procedures performed on humans requires anatomically accurate, computational models. These may be constructed from medical images as voxel-based tomographic models. However, they are time consuming to produce and as a consequence, there are few available. This paper discusses the emergence of semi-automatic segmentation techniques and describes an application (iRAD) written in Microsoft Visual Basic that allows the bitmap of a medical image to be segmented interactively and semi-automatically while displayed in Microsoft Excel. iRAD will decrease the time required to construct voxel models. Copyright (2001) Australasian College of Physical Scientists and Engineers in Medicine

  9. Software development for modeling positrons emission tomograph scanners

    International Nuclear Information System (INIS)

    Vieira, Igor Fagner

    2013-01-01

    The Geant4 Application for Tomographic Emission (GATE) is an international platform recognized and used to develop Computational Model Exposure (CME) in the context of Nuclear Medicine, although currently there are dedicated modules for applications in Radiotherapy and Computed Tomography (CT). GATE uses Monte Carlo (MC) methods, and has a scripting language of its own. The writing of scripts for simulation of a PET scanner in GATE involves a number of interrelated steps, and the accuracy of the simulation is dependent on the correct setup of the geometries involved, since the physical processes depend on them, as well as the modeling of electronic detectors in module Digitizer, for example. The manual implementation of this setup can be a source of errors, especially for users without experience in the field of simulations or without any previous knowledge of a programming language, and also due to the the fact that the modeling process in GATE still remains bounded to LINUX / UNIX based systems, an environment only familiar to a few. This becomes an obstacle for beginners and prevents the use of GATE by a larger number of users interested in optimizing their experiments and/or clinical protocols through a more accessible, fast and friendly application. The objective of this work is therefore to develop a user-friendly software for the modeling of Positron Emission Tomography called GUIGATE (Graphical User Interface for GATE), with specific modules dedicated to quality control in PET scanners. The results exhibit the features available in this first version of GUIGATE, present in a set of windows that allow users to create their input files, perform and display in real time the model and analyze its output file in a single environment, allowing so intuitively access the entire architecture of the GATE simulation and to CERN's data analyzer, the ROOT. (author)

  10. TomoPy: a framework for the analysis of synchrotron tomographic data

    International Nuclear Information System (INIS)

    Gürsoy, Doǧa; De Carlo, Francesco; Xiao, Xianghui; Jacobsen, Chris

    2014-01-01

    A collaborative framework for the analysis of synchrotron tomographic data which has the potential to unify the effort of different facilities and beamlines performing similar tasks is described. The proposed Python-based framework is open-source, platform- and data-format-independent, has multiprocessing capability and supports functional programming that many researchers prefer. Analysis of tomographic datasets at synchrotron light sources (including X-ray transmission tomography, X-ray fluorescence microscopy and X-ray diffraction tomography) is becoming progressively more challenging due to the increasing data acquisition rates that new technologies in X-ray sources and detectors enable. The next generation of synchrotron facilities that are currently under design or construction throughout the world will provide diffraction-limited X-ray sources and are expected to boost the current data rates by several orders of magnitude, stressing the need for the development and integration of efficient analysis tools. Here an attempt to provide a collaborative framework for the analysis of synchrotron tomographic data that has the potential to unify the effort of different facilities and beamlines performing similar tasks is described in detail. The proposed Python-based framework is open-source, platform- and data-format-independent, has multiprocessing capability and supports procedural programming that many researchers prefer. This collaborative platform could affect all major synchrotron facilities where new effort is now dedicated to developing new tools that can be deployed at the facility for real-time processing, as well as distributed to users for off-site data processing

  11. TomoPy: a framework for the analysis of synchrotron tomographic data

    Energy Technology Data Exchange (ETDEWEB)

    Gürsoy, Doǧa, E-mail: dgursoy@aps.anl.gov; De Carlo, Francesco; Xiao, Xianghui; Jacobsen, Chris [Advanced Photon Source, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439-4837 (United States)

    2014-08-01

    A collaborative framework for the analysis of synchrotron tomographic data which has the potential to unify the effort of different facilities and beamlines performing similar tasks is described. The proposed Python-based framework is open-source, platform- and data-format-independent, has multiprocessing capability and supports functional programming that many researchers prefer. Analysis of tomographic datasets at synchrotron light sources (including X-ray transmission tomography, X-ray fluorescence microscopy and X-ray diffraction tomography) is becoming progressively more challenging due to the increasing data acquisition rates that new technologies in X-ray sources and detectors enable. The next generation of synchrotron facilities that are currently under design or construction throughout the world will provide diffraction-limited X-ray sources and are expected to boost the current data rates by several orders of magnitude, stressing the need for the development and integration of efficient analysis tools. Here an attempt to provide a collaborative framework for the analysis of synchrotron tomographic data that has the potential to unify the effort of different facilities and beamlines performing similar tasks is described in detail. The proposed Python-based framework is open-source, platform- and data-format-independent, has multiprocessing capability and supports procedural programming that many researchers prefer. This collaborative platform could affect all major synchrotron facilities where new effort is now dedicated to developing new tools that can be deployed at the facility for real-time processing, as well as distributed to users for off-site data processing.

  12. Designing Preclinical Instruction of Psychomotor Skills (IV)--Instructional Engineering: Evaluation Phase.

    Science.gov (United States)

    Guenzel, Pamela J.; And Others

    1995-01-01

    The fourth article in a four-part series on instructional design discusses evaluation of a psychomotor skills unit taught in preclinical dental education. Issues examined include piloting of instructional materials, analysis and revision of materials based on student performance, syllabus design and content, influence of faculty characteristics,…

  13. Evolution of strategies to improve preclinical cardiac safety testing.

    Science.gov (United States)

    Gintant, Gary; Sager, Philip T; Stockbridge, Norman

    2016-07-01

    The early and efficient assessment of cardiac safety liabilities is essential to confidently advance novel drug candidates. This article discusses evolving mechanistically based preclinical strategies for detecting drug-induced electrophysiological and structural cardiotoxicity using in vitro human ion channel assays, human-based in silico reconstructions and human stem cell-derived cardiomyocytes. These strategies represent a paradigm shift from current approaches, which rely on simplistic in vitro assays that measure blockade of the Kv11.1 current (also known as the hERG current or IKr) and on the use of non-human cells or tissues. These new strategies have the potential to improve sensitivity and specificity in the early detection of genuine cardiotoxicity risks, thereby reducing the likelihood of mistakenly discarding viable drug candidates and speeding the progression of worthy drugs into clinical trials.

  14. Stem Cells for Cartilage Repair: Preclinical Studies and Insights in Translational Animal Models and Outcome Measures

    Directory of Open Access Journals (Sweden)

    Melissa Lo Monaco

    2018-01-01

    Full Text Available Due to the restricted intrinsic capacity of resident chondrocytes to regenerate the lost cartilage postinjury, stem cell-based therapies have been proposed as a novel therapeutic approach for cartilage repair. Moreover, stem cell-based therapies using mesenchymal stem cells (MSCs or induced pluripotent stem cells (iPSCs have been used successfully in preclinical and clinical settings. Despite these promising reports, the exact mechanisms underlying stem cell-mediated cartilage repair remain uncertain. Stem cells can contribute to cartilage repair via chondrogenic differentiation, via immunomodulation, or by the production of paracrine factors and extracellular vesicles. But before novel cell-based therapies for cartilage repair can be introduced into the clinic, rigorous testing in preclinical animal models is required. Preclinical models used in regenerative cartilage studies include murine, lapine, caprine, ovine, porcine, canine, and equine models, each associated with its specific advantages and limitations. This review presents a summary of recent in vitro data and from in vivo preclinical studies justifying the use of MSCs and iPSCs in cartilage tissue engineering. Moreover, the advantages and disadvantages of utilizing small and large animals will be discussed, while also describing suitable outcome measures for evaluating cartilage repair.

  15. Stem Cells for Cartilage Repair: Preclinical Studies and Insights in Translational Animal Models and Outcome Measures.

    Science.gov (United States)

    Lo Monaco, Melissa; Merckx, Greet; Ratajczak, Jessica; Gervois, Pascal; Hilkens, Petra; Clegg, Peter; Bronckaers, Annelies; Vandeweerd, Jean-Michel; Lambrichts, Ivo

    2018-01-01

    Due to the restricted intrinsic capacity of resident chondrocytes to regenerate the lost cartilage postinjury, stem cell-based therapies have been proposed as a novel therapeutic approach for cartilage repair. Moreover, stem cell-based therapies using mesenchymal stem cells (MSCs) or induced pluripotent stem cells (iPSCs) have been used successfully in preclinical and clinical settings. Despite these promising reports, the exact mechanisms underlying stem cell-mediated cartilage repair remain uncertain. Stem cells can contribute to cartilage repair via chondrogenic differentiation, via immunomodulation, or by the production of paracrine factors and extracellular vesicles. But before novel cell-based therapies for cartilage repair can be introduced into the clinic, rigorous testing in preclinical animal models is required. Preclinical models used in regenerative cartilage studies include murine, lapine, caprine, ovine, porcine, canine, and equine models, each associated with its specific advantages and limitations. This review presents a summary of recent in vitro data and from in vivo preclinical studies justifying the use of MSCs and iPSCs in cartilage tissue engineering. Moreover, the advantages and disadvantages of utilizing small and large animals will be discussed, while also describing suitable outcome measures for evaluating cartilage repair.

  16. Tomographic findings of acute pulmonary toxoplasmosis in immunocompetent patients.

    Science.gov (United States)

    de Souza Giassi, Karina; Costa, Andre Nathan; Apanavicius, Andre; Teixeira, Fernando Bin; Fernandes, Caio Julio Cesar; Helito, Alfredo Salim; Kairalla, Ronaldo Adib

    2014-11-25

    Toxoplasmosis is one of the most common human zoonosis, and is generally benign in most of the individuals. Pulmonary involvement is common in immunocompromised subjects, but very rare in immunocompetents and there are scarce reports of tomographic findings in the literature. The aim of the study is to describe three immunocompetent patients diagnosed with acute pulmonary toxoplasmosis and their respective thoracic tomographic findings. Acute toxoplasmosis was diagnosed according to the results of serological tests suggestive of recent primary infection and the absence of an alternative etiology. From 2009 to 2013, three patients were diagnosed with acute respiratory failure secondary to acute toxoplasmosis. The patients were two female and one male, and were 38, 56 and 36 years old. Similarly they presented a two-week febrile illness and progressive dyspnea before admission. Laboratory tests demonstrated lymphocytosis, slight changes in liver enzymes and high inflammatory markers. Tomographic findings were bilateral smooth septal and peribronchovascular thickening (100%), ground-glass opacities (100%), atelectasis (33%), random nodules (33%), lymph node enlargement (33%) and pleural effusion (66%). All the patients improved their symptoms after treatment, and complete resolution of tomographic findings were found in the followup. These cases provide a unique description of the presentation and evolution of pulmonary tomographic manifestations of toxoplasmosis in immunocompetent patients. Toxoplasma pneumonia manifests with fever, dyspnea and a non-productive cough that may result in respiratory failure. In animal models, changes were described as interstitial pneumonitis with focal infiltrates of neutrophils that can finally evolve into a pattern of diffuse alveolar damage with focal necrosis. The tomographic findings are characterized as ground glass opacities, smooth septal and marked peribronchovascular thickening; and may mimic pulmonary congestion

  17. Development of a tomographic system adapted to 3D measurement of contaminated wounds based on the Cacao concept (Computer aided collimation Gamma Camera); Developpement a partir du concept CACAO (Camera A Collimation Assistee par Ordinateur) d'un systeme tomographique adapte a la mesure 3D de plaies contaminees

    Energy Technology Data Exchange (ETDEWEB)

    Douiri, A

    2002-03-01

    The computer aided collimation gamma camera (CACAO in French) is a gamma camera using a collimator with large holes, a supplementary linear scanning motion during the acquisition and a dedicated reconstruction program taking full account of the source depth. The CACAO system was introduced to improve both the sensitivity and the resolution in nuclear medicine. This thesis focuses on the design of a fast and robust reconstruction algorithm in the CACAO project. We start by an overview of tomographic imaging techniques in nuclear medicine. After modelling the physical CACAO system, we present the complete reconstruction program which involves three steps: 1) shift and sum 2) deconvolution and filtering 3) rotation and sum. The deconvolution is the critical step that decreases the signal to noise ratio of the reconstructed images. We propose a regularized multi-channel algorithm to solve the deconvolution problem. We also present a fast algorithm based on Splines functions and preserving the high quality of the reconstructed images for the shift and the rotation steps. Comparisons of simulated reconstructed images in 2D and 3D for the conventional system (CPHC) and CACAO demonstrate the ability of CACAO system to increase the quality of the SPECT images. Finally, this study concludes with an experimental approach with a pixellated detector conceived for a 3D measurement of contaminated wounds. This experimentation proves the possible advantages of coupling the CACAO project with pixellated detectors. Moreover, a variety of applications could fully benefit from the CACAO system, such as low activity imaging, the use of high-energy gamma isotopes and the visualization of deep organs. Moreover the combination of the CACAO system with a pixels detector may open up further possibilities for the future of nuclear medicine. (author)

  18. easyPET: a novel concept for an affordable tomographic system

    International Nuclear Information System (INIS)

    Arosio, V.; Caccia, M.; Castro, I.F.; Correia, P.M.M.; Mattone, C.; Moutinho, L.M.; Santoro, R.; Silva, A.L.M.; Veloso, J.F.C.A.

    2017-01-01

    The easyPET concept described here aims to reduce complexity and cost of preclinical Positron Emission Tomography (PET) scanners. The system, original in its principle and realisation, is based on a single pair of detectors and a rotating mechanism with two degrees of freedom reproducing the functionalities of an entire PET ring. The characterisation of a 2D imaging prototype, realised to assess the easyPET concept, is presented in this paper. In particular, a spatial resolution of 1±0.1 mm and a sensitivity of 0.1% with an energy threshold of 80 keV have been measured. These encouraging results, compared to the performances of commercial preclinical PET, motivate the feasibility study of a 3D system.

  19. easyPET: a novel concept for an affordable tomographic system

    Energy Technology Data Exchange (ETDEWEB)

    Arosio, V., E-mail: varosio@studenti.uninsubria.it [Dipartimento di Scienza e Alta Tecnologia, Università degli Studi dell' Insubria, Via Valleggio 11, 22100 Como (Italy); Caccia, M. [Dipartimento di Scienza e Alta Tecnologia, Università degli Studi dell' Insubria, Via Valleggio 11, 22100 Como (Italy); Castro, I.F.; Correia, P.M.M. [i3n, Departamento de Fisica, Univerdisade de Aveiro, Campus Universitario de Santiago, 3810-193 Aveiro (Portugal); Mattone, C. [Dipartimento di Scienza e Alta Tecnologia, Università degli Studi dell' Insubria, Via Valleggio 11, 22100 Como (Italy); Moutinho, L.M. [i3n, Departamento de Fisica, Univerdisade de Aveiro, Campus Universitario de Santiago, 3810-193 Aveiro (Portugal); Santoro, R. [Dipartimento di Scienza e Alta Tecnologia, Università degli Studi dell' Insubria, Via Valleggio 11, 22100 Como (Italy); Silva, A.L.M.; Veloso, J.F.C.A. [i3n, Departamento de Fisica, Univerdisade de Aveiro, Campus Universitario de Santiago, 3810-193 Aveiro (Portugal)

    2017-02-11

    The easyPET concept described here aims to reduce complexity and cost of preclinical Positron Emission Tomography (PET) scanners. The system, original in its principle and realisation, is based on a single pair of detectors and a rotating mechanism with two degrees of freedom reproducing the functionalities of an entire PET ring. The characterisation of a 2D imaging prototype, realised to assess the easyPET concept, is presented in this paper. In particular, a spatial resolution of 1±0.1 mm and a sensitivity of 0.1% with an energy threshold of 80 keV have been measured. These encouraging results, compared to the performances of commercial preclinical PET, motivate the feasibility study of a 3D system.

  20. Bone Microarchitecture and Estimated Strength in 499 Adult Danish Women and Men: A Cross-Sectional, Population-Based High-Resolution Peripheral Quantitative Computed Tomographic Study on Peak Bone Structure

    DEFF Research Database (Denmark)

    Hansen, Stinus; Shanbhogue, V.; Folkestad, L.

    2014-01-01

    High-resolution peripheral quantitative computed tomography (HR-pQCT) allows in vivo assessment of cortical and trabecular bone mineral density (BMD), geometry, and microarchitecture at the distal radius and tibia in unprecedented detail. In this cross-sectional study, we provide normative and de...... and descriptive HR-pQCT data from a large population-based sample of Danish Caucasian women and men (n = 499) aged 20-80 years. In young adults (...

  1. Design and applications of Computed Industrial Tomographic Imaging System (CITIS)

    International Nuclear Information System (INIS)

    Ramakrishna, G.S.; Umesh Kumar; Datta, S.S.; Rao, S.M.

    1996-01-01

    Computed tomographic imaging is an advanced technique for nondestructive testing (NDT) and examination. For the first time in India a computed aided tomography system has been indigenously developed in BARC for testing industrial components and was successfully demonstrated. The system in addition to Computed Tomography (CT) can also perform Digital Radiography (DR) to serve as a powerful tool for NDT applications. It has wider applications in the fields of nuclear, space and allied fields. The authors have developed a computed industrial tomographic imaging system with Cesium 137 gamma radiation source for nondestructive examination of engineering and industrial specimens. This presentation highlights the design and development of a prototype system and its software for image reconstruction, simulation and display. The paper also describes results obtained with several tests specimens, current development and possibility of using neutrons as well as high energy x-rays in computed tomography. (author)

  2. Time-resolved tomographic images of a relativistic electron beam

    International Nuclear Information System (INIS)

    Koehler, H.A.; Jacoby, B.A.; Nelson, M.

    1984-07-01

    We obtained a sequential series of time-resolved tomographic two-dimensional images of a 4.5-MeV, 6-kA, 30-ns electron beam. Three linear fiber-optic arrays of 30 or 60 fibers each were positioned around the beam axis at 0 0 , 61 0 , and 117 0 . The beam interacting with nitrogen at 20 Torr emitted light that was focused onto the fiber arrays and transmitted to a streak camera where the data were recorded on film. The film was digitized, and two-dimensional images were reconstructed using the maximum-entropy tomographic technique. These images were then combined to produce an ultra-high-speed movie of the electron-beam pulse

  3. The CDD system in computed tomographic diagnosis of diverticular disease

    International Nuclear Information System (INIS)

    Pustelnik, Daniel; Elsholtz, Fabian Henry Juergen; Hamm, Bernd; Niehues, Stefan Markus; Bojarski, Christian

    2017-01-01

    Purpose cation in computed tomographic diagnosis and briefly recapitulates its targeted advantages over preliminary systems. Primarily, application of the CDD in computed tomography diagnostics is described. Differences with respect to the categories of the older systems are pointed out on the level of each CDD type using imaging examples. The presented images are derived from our institute according to the S2k criteria. Literature was researched on PubMed. Results The CDD constitutes an improvement compared to older systems for categorizing the stages of diverticular disease. It provides more discriminatory power on the descriptive-morphological level and defines as well as differentiates more courses of the disease. Furthermore, the categories translate more directly into state-of-the-art decision-making concerning hospitalization and therapy. The CDD should be applied routinely in the computed tomographic diagnosis of diverticular disease. Typical imaging patterns are presented.

  4. Terahertz Imaging for Biomedical Applications Pattern Recognition and Tomographic Reconstruction

    CERN Document Server

    Yin, Xiaoxia; Abbott, Derek

    2012-01-01

    Terahertz Imaging for Biomedical Applications: Pattern Recognition and Tomographic Reconstruction presents the necessary algorithms needed to assist screening, diagnosis, and treatment, and these algorithms will play a critical role in the accurate detection of abnormalities present in biomedical imaging. Terahertz biomedical imaging has become an area of interest due to its ability to simultaneously acquire both image and spectral information. Terahertz imaging systems are being commercialized with an increasing number of trials performed in a biomedical setting. Terahertz tomographic imaging and detection technology contributes to the ability to identify opaque objects with clear boundaries,and would be useful to both in vivo and ex vivo environments. This book also: Introduces terahertz radiation techniques and provides a number of topical examples of signal and image processing, as well as machine learning Presents the most recent developments in an emerging field, terahertz radiation Utilizes new methods...

  5. Minimum Detectable Activity for Tomographic Gamma Scanning System

    Energy Technology Data Exchange (ETDEWEB)

    Venkataraman, Ram [Canberra Industries (AREVA BDNM), Meriden, CT (United States); Smith, Susan [Canberra Industries (AREVA BDNM), Meriden, CT (United States); Kirkpatrick, J. M. [Canberra Industries (AREVA BDNM), Meriden, CT (United States); Croft, Stephen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-01-01

    For any radiation measurement system, it is useful to explore and establish the detection limits and a minimum detectable activity (MDA) for the radionuclides of interest, even if the system is to be used at far higher values. The MDA serves as an important figure of merit, and often a system is optimized and configured so that it can meet the MDA requirements of a measurement campaign. The non-destructive assay (NDA) systems based on gamma ray analysis are no exception and well established conventions, such the Currie method, exist for estimating the detection limits and the MDA. However, the Tomographic Gamma Scanning (TGS) technique poses some challenges for the estimation of detection limits and MDAs. The TGS combines high resolution gamma ray spectrometry (HRGS) with low spatial resolution image reconstruction techniques. In non-imaging gamma ray based NDA techniques measured counts in a full energy peak can be used to estimate the activity of a radionuclide, independently of other counting trials. However, in the case of the TGS each “view” is a full spectral grab (each a counting trial), and each scan consists of 150 spectral grabs in the transmission and emission scans per vertical layer of the item. The set of views in a complete scan are then used to solve for the radionuclide activities on a voxel by voxel basis, over 16 layers of a 10x10 voxel grid. Thus, the raw count data are not independent trials any more, but rather constitute input to a matrix solution for the emission image values at the various locations inside the item volume used in the reconstruction. So, the validity of the methods used to estimate MDA for an imaging technique such as TGS warrant a close scrutiny, because the pair-counting concept of Currie is not directly applicable. One can also raise questions as to whether the TGS, along with other image reconstruction techniques which heavily intertwine data, is a suitable method if one expects to measure samples whose activities

  6. Heidelberg Retina Tomograph for the Detection of Glaucoma

    Directory of Open Access Journals (Sweden)

    Barbara Cvenkel

    2012-06-01

    Full Text Available Heidelberg Retina Tomograph (HRT is a confocal scanning laser ophthalmoscope which acquires and analyzes 3-dimensional images of the optic nerve head. The latest instrument HRT3 includes software with larger ethinic-specific normative database. This review summarizes relevant published literature on HRT in diagnosing glaucoma, detecting glaucoma progression, the diagnostic accuracy of HRT among other imaging devices and its role in clinical practice.

  7. Computed tomographic diagnosis of abdominal abscess in childhood

    International Nuclear Information System (INIS)

    Kuhn, J.P.; Berger, P.E.

    1980-01-01

    Twenty-eight children suspected clinically of having an abdominal abscess were examined by CT. Eighteen had gallium 67 citrate scans and 22 had ultrasound studies. Computed tomography was found to be the most accurate test for diagnosis and evaluation of an abscess and the computed tomographic appearance of abscess is illustrated. However, because of cost factors, radiation dose, and clinical considerations, computed tomography is not always the first modality of choice in evaluating a suspected abdominal abscess [fr

  8. A general purpose tomographic program with combined inversions

    International Nuclear Information System (INIS)

    Xu Wenbin; Dong Jiafu; Li Fanzhu

    1996-01-01

    A general tomographic program has been developed by combining the Bessel expansion with the Zernicke expansion. It is useful for studying of the magnetic island structure of the tearing mode and in reconstructing the density profiles of impurities in tokamak plasmas. This combined method have the advantages of both expansions, i.e. there will be no spurious images in the edge and it will be of high inverse precision in the center of plasma

  9. Computer tomographic detection of an intraspinal arachnoidal cyst

    International Nuclear Information System (INIS)

    Kuckein, D.; Walter, K.; Paal, G.; Staedtisches Krankenhaus Harlaching, Muenchen

    1981-01-01

    A 46 year old female patient who after 3-4 weeks of influenza suffered from strong headaches, vomiting and rotatory vertigo was subjected to a myelograph and then to a computerized tomographic investigation due to suspect cerebrospinal fluid. The computerized tomography is better than the myelography in diagnosing intraspinal arachnoidal cysts, however this should be preceded by most accurate possible segment location. (MG) [de

  10. Initial results from the Donner 600-crystal positron tomograph

    International Nuclear Information System (INIS)

    Derenzo, S.E.; Huesman, R.H.; Cahoon, J.L.; Geyer, A.B.; Uber, D.C.; Vuletich, T.; Budinger, T.F.

    1987-01-01

    These results show the 3-mm BGO crystals can improve the resolution in positron tomography by a substantial factor. This measured crystal-pair resolution of 2.4 mm FWHM and the reconstructed image resolution of 2.9 mm FWHM at the center of the tomograph are in good agreement with expected values. The most serious limitation of the detector design is that only a single section can be imaged. 4 refs., 4 figs

  11. Computer tomographic evaluation of digestive tract non-Hodgkin lymphomas.

    Science.gov (United States)

    Lupescu, Ioana G; Grasu, Mugur; Goldis, Gheorghe; Popa, Gelu; Gheorghe, Cristian; Vasilescu, Catalin; Moicean, Andreea; Herlea, Vlad; Georgescu, Serban A

    2007-09-01

    Computer Tomographic (CT) study is crucial for defining distribution, characteristics and staging of primary gastrointestinal lymphomas. The presence of multifocal sites, the wall thickening with diffuse infiltration of the affected gastrointestinal (GI) segment in association with regional adenopathies, permit the orientation of the CT diagnosis for primary GI lymphomas. The gold standard for diagnosis remains, in all cases of digestive tract non-Hodgkin lymphomas (NHL), the histological examination, which allows a tissue diagnosis, performed preferably by transmural biopsy.

  12. Supramolecular nano-engineered lipidic carriers based on diflunisal-phospholipid complex for transdermal delivery: QbD based optimization, characterization and preclinical investigations for management of rheumatoid arthritis.

    Science.gov (United States)

    Kaur, Amanpreet; Bhoop, Bhupinder Singh; Chhibber, Sanjay; Sharma, Gajanand; Gondil, Vijay Singh; Katare, Om Prakash

    2017-11-25

    Diflunisal (DIF) is used for treatment of rheumatoid arthritis, osteoarthritis etc. DIF-phospholipid complex (DIF-PL complex) was prepared by solvent-evaporation method and characterized by molecular docking studies, SEM, FTIR, DSC, PXRD studies. Further, the DIF-PL complex was incorporated into supramolecular nano-engineered lipidic carriers (SNLCs) for transdermal delivery. The optimization exercise was done using Face centered cubic design (FCCD) after screening of variables by L8 Taguchi orthogonal array design. The optimized SNLC formulation depicted average particle size (188.1nm), degree of entrapment (86.77±3.33%), permeation flux (5.47±0.48μg/cm 2 /h) and skin retention (17.72±0.68μg/cm 2 ). The dermatokinetic studies revealed the higher concentration of DIF in dermis. The Confocal laser scanning microscopy (CSLM) studies revealed penetration of SNLCs into the deeper layers of skin. The results of mice ear edema depicted significant inhibition of ear edema (76.37±12.52%; prheumatoid arthritis model, the inhibition of paw edema was significantly higher (73.85±14.5%). The levels of TNF-α were reduced in synovial fluid (146.74±1.69pg/mL) and serum (132.43±2.70pg/mL). Furthermore, the licking and biting time was reduced in formalin induced hyperalgesia model. Hence, it can be concluded that dual formulation strategy based SNLCs were promising in treatment of pain and inflammation associated with rheumatoid arthritis. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Common pitfalls in preclinical cancer target validation.

    Science.gov (United States)

    Kaelin, William G

    2017-07-01

    An alarming number of papers from laboratories nominating new cancer drug targets contain findings that cannot be reproduced by others or are simply not robust enough to justify drug discovery efforts. This problem probably has many causes, including an underappreciation of the danger of being misled by off-target effects when using pharmacological or genetic perturbants in complex biological assays. This danger is particularly acute when, as is often the case in cancer pharmacology, the biological phenotype being measured is a 'down' readout (such as decreased proliferation, decreased viability or decreased tumour growth) that could simply reflect a nonspecific loss of cellular fitness. These problems are compounded by multiple hypothesis testing, such as when candidate targets emerge from high-throughput screens that interrogate multiple targets in parallel, and by a publication and promotion system that preferentially rewards positive findings. In this Perspective, I outline some of the common pitfalls in preclinical cancer target identification and some potential approaches to mitigate them.

  14. An introduction to the tomographic picture of quantum mechanics

    International Nuclear Information System (INIS)

    Ibort, A; Man'ko, V I; Marmo, G; Simoni, A; Ventriglia, F

    2009-01-01

    Starting from the famous Pauli problem on the possibility of associating quantum states with probabilities, the formulation of quantum mechanics in which quantum states are described by fair probability distributions (tomograms, i.e. tomographic probabilities) is reviewed in a pedagogical style. The relation between the quantum state description and the classical state description is elucidated. The difference between those sets of tomograms is described by inequalities equivalent to a complete set of uncertainty relations for the quantum domain and to non-negativity of probability density on phase space in the classical domain. The intersection of such sets is studied. The mathematical mechanism that allows us to construct different kinds of tomographic probabilities like symplectic tomograms, spin tomograms, photon number tomograms, etc is clarified and a connection with abstract Hilbert space properties is established. The superposition rule and uncertainty relations in terms of probabilities as well as quantum basic equations like quantum evolution and energy spectra equations are given in an explicit form. A method to check experimentally the uncertainty relations is suggested using optical tomograms. Entanglement phenomena and the connection with semigroups acting on simplexes are studied in detail for spin states in the case of two-qubits. The star-product formalism is associated with the tomographic probability formulation of quantum mechanics.

  15. Tomographic Particle Image Velocimetry Using Colored Shadow Imaging

    KAUST Repository

    Alarfaj, Meshal K.

    2016-02-01

    Tomographic Particle Image Velocimetry Using Colored Shadow Imaging by Meshal K Alarfaj, Master of Science King Abdullah University of Science & Technology, 2015 Tomographic Particle image velocimetry (PIV) is a recent PIV method capable of reconstructing the full 3D velocity field of complex flows, within a 3-D volume. For nearly the last decade, it has become the most powerful tool for study of turbulent velocity fields and promises great advancements in the study of fluid mechanics. Among the early published studies, a good number of researches have suggested enhancements and optimizations of different aspects of this technique to improve the effectiveness. One major aspect, which is the core of the present work, is related to reducing the cost of the Tomographic PIV setup. In this thesis, we attempt to reduce this cost by using an experimental setup exploiting 4 commercial digital still cameras in combination with low-cost Light emitting diodes (LEDs). We use two different colors to distinguish the two light pulses. By using colored shadows with red and green LEDs, we can identify the particle locations within the measurement volume, at the two different times, thereby allowing calculation of the velocities. The present work tests this technique on the flows patterns of a jet ejected from a tube in a water tank. Results from the images processing are presented and challenges discussed.

  16. Field experience with a mobile tomographic nondestructive assay system

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Betts, S.E.; Taggart, D.P.; Estep, R.J.; Nicholas, N.J.; Lucas, M.C.; Harlan, R.A.

    1995-01-01

    A mobile tomographic gamma-ray scanner (TGS) developed by Los Alamos National Laboratory was recently demonstrated at the Rocky Flats Environmental Technology Site and is currently in use at Los Alamos waste storage areas. The scanner was developed to assay radionuclides in low-level, transuranic, and mixed waste in containers ranging in size from 2 ft 3 boxes to 83-gallon overpacks. The tomographic imaging capability provides a complete correction for source distribution and matrix attenuation effects, enabling accurate assays of Pu-239 and other gamma-ray emitting isotopes. In addition, the system can reliably detect self-absorbing material such as plutonium metal shot, and can correct for bias caused by self-absorption. The system can be quickly configured to execute far-field scans, segmented gamma-ray scans, and a host of intermediate scanning protocols, enabling higher throughput (up to 20 drums per 8-hour shift). In this paper, we will report on the results of field trials of the mobile system at Rocky Flats and Los Alamos. Assay accuracy is confirmed for cases in which TGS assays can be compared with assays (e.g. with calorimetry) of individual packages within the drums. The mobile tomographic technology is expected to considerably reduce characterization costs at DOE production and environmental technology sites

  17. Tomographic findings of lobar consolidation in primary pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Pereira, Bruno Alberto Falcao; Macedo, Solange Goncalves David de; Penna, Claudia Renata Rezende

    2009-01-01

    Objective: To describe tomographic findings of lobar consolidation as early manifestation of primary pulmonary tuberculosis. Materials and methods: The present study was developed at Hospital Municipal Jesus, Rio de Janeiro, RJ, Brazil, in the period between 2002 and 2006, retrospectively evaluating tomographic findings in four children aged from 3 to 14 months with lobar consolidation as an early manifestation of primary pulmonary tuberculosis. Results: The most frequently found radiological pattern was lobar consolidation with calcifications, cavitation and intermingle necrotic areas, associated with bulging fissure. Signs of bronchogenic dissemination and lymph node enlargement were observed in all of the four children. Consolidation with a pseudotumor aspect and masslike effect was observed in one case. Conclusion: The cases included in the present study have demonstrated that primary pulmonary tuberculosis manifested as lobar consolidation presents typical tomographic images such as cavitation, hypodense areas and calcifications intermingled with consolidation. The association with lymph node enlargement with central necrosis and signs of bronchogenic dissemination reinforce the diagnosis of tuberculosis. (author)

  18. Characterization of Pharmacologic and Pharmacokinetic Properties of CCX168, a Potent and Selective Orally Administered Complement 5a Receptor Inhibitor, Based on Preclinical Evaluation and Randomized Phase 1 Clinical Study.

    Science.gov (United States)

    Bekker, Pirow; Dairaghi, Daniel; Seitz, Lisa; Leleti, Manmohan; Wang, Yu; Ertl, Linda; Baumgart, Trageen; Shugarts, Sarah; Lohr, Lisa; Dang, Ton; Miao, Shichang; Zeng, Yibin; Fan, Pingchen; Zhang, Penglie; Johnson, Daniel; Powers, Jay; Jaen, Juan; Charo, Israel; Schall, Thomas J

    2016-01-01

    The complement 5a receptor has been an attractive therapeutic target for many autoimmune and inflammatory disorders. However, development of a selective and potent C5aR antagonist has been challenging. Here we describe the characterization of CCX168 (avacopan), an orally administered selective and potent C5aR inhibitor. CCX168 blocked the C5a binding, C5a-mediated migration, calcium mobilization, and CD11b upregulation in U937 cells as well as in freshly isolated human neutrophils. CCX168 retains high potency when present in human blood. A transgenic human C5aR knock-in mouse model allowed comparison of the in vitro and in vivo efficacy of the molecule. CCX168 effectively blocked migration in in vitro and ex vivo chemotaxis assays, and it blocked the C5a-mediated neutrophil vascular endothelial margination. CCX168 was effective in migration and neutrophil margination assays in cynomolgus monkeys. This thorough in vitro and preclinical characterization enabled progression of CCX168 into the clinic and testing of its safety, tolerability, pharmacokinetic, and pharmacodynamic profiles in a Phase 1 clinical trial in 48 healthy volunteers. CCX168 was shown to be well tolerated across a broad dose range (1 to 100 mg) and it showed dose-dependent pharmacokinetics. An oral dose of 30 mg CCX168 given twice daily blocked the C5a-induced upregulation of CD11b in circulating neutrophils by 94% or greater throughout the entire day, demonstrating essentially complete target coverage. This dose regimen is being tested in clinical trials in patients with anti-neutrophil cytoplasmic antibody-associated vasculitis. Trial Registration ISRCTN registry with trial ID ISRCTN13564773.

  19. Characterization of Pharmacologic and Pharmacokinetic Properties of CCX168, a Potent and Selective Orally Administered Complement 5a Receptor Inhibitor, Based on Preclinical Evaluation and Randomized Phase 1 Clinical Study.

    Directory of Open Access Journals (Sweden)

    Pirow Bekker

    Full Text Available The complement 5a receptor has been an attractive therapeutic target for many autoimmune and inflammatory disorders. However, development of a selective and potent C5aR antagonist has been challenging. Here we describe the characterization of CCX168 (avacopan, an orally administered selective and potent C5aR inhibitor. CCX168 blocked the C5a binding, C5a-mediated migration, calcium mobilization, and CD11b upregulation in U937 cells as well as in freshly isolated human neutrophils. CCX168 retains high potency when present in human blood. A transgenic human C5aR knock-in mouse model allowed comparison of the in vitro and in vivo efficacy of the molecule. CCX168 effectively blocked migration in in vitro and ex vivo chemotaxis assays, and it blocked the C5a-mediated neutrophil vascular endothelial margination. CCX168 was effective in migration and neutrophil margination assays in cynomolgus monkeys. This thorough in vitro and preclinical characterization enabled progression of CCX168 into the clinic and testing of its safety, tolerability, pharmacokinetic, and pharmacodynamic profiles in a Phase 1 clinical trial in 48 healthy volunteers. CCX168 was shown to be well tolerated across a broad dose range (1 to 100 mg and it showed dose-dependent pharmacokinetics. An oral dose of 30 mg CCX168 given twice daily blocked the C5a-induced upregulation of CD11b in circulating neutrophils by 94% or greater throughout the entire day, demonstrating essentially complete target coverage. This dose regimen is being tested in clinical trials in patients with anti-neutrophil cytoplasmic antibody-associated vasculitis. Trial Registration ISRCTN registry with trial ID ISRCTN13564773.

  20. Longitudinal trends and subgroup analysis in publication patterns for preclinical data of newly approved drugs.

    Science.gov (United States)

    Köster, Ursula; Nolte, Ingo; Michel, Martin C

    2016-02-01

    Having observed a large variation in the number and type of original preclinical publications for newly registered drugs, we have explored whether longitudinal trends and/or factors specific for certain drugs or their manufacturers may explain such variation. Our analysis is based on 1954 articles related to 170 newly approved drugs. The number of preclinical publications per compound declined from a median of 10.5 in 1991 to 3 in 2011. A similar trend was observed for the number of in vivo studies in general, but not in the subset of in vivo studies in animal models of disease. The percentage of compounds with studies using isolated human cells or cell lines almost doubled over time from 37 to 72%. Number of publications did not exhibit major differences between compounds intended for human versus veterinary use, therapeutic areas, small molecules versus biologicals, or innovator versus follow-up compounds; however, some companies may publish fewer studies per compound than others. However, there were qualitative differences in the types of models being used depending on the therapeutic area; specifically, compounds for use in oncology very often used isolated cells and cell lines, often from human origin. We conclude that the large variation in number and type of reported preclinical data is not easily explained. We propose that pharmaceutical companies should consistently provide a comprehensive documentation of the preclinical data they generate as part of their development programs in the public domain to enable a better understanding of the drugs they intend to market.

  1. Computed Tomographic Analysis of Ventral Atlantoaxial Optimal Safe Implantation Corridors in 27 Dogs.

    Science.gov (United States)

    Leblond, Guillaume; Gaitero, Luis; Moens, Noel M M; Zur Linden, Alex; James, Fiona M K; Monteith, Gabrielle J; Runciman, John

    2017-11-01

    Objectives  Ventral atlantoaxial stabilization techniques are challenging surgical procedures in dogs. Available surgical guidelines are based upon subjective anatomical landmarks, and limited radiographic and computed tomographic data. The aims of this study were (1) to provide detailed anatomical descriptions of atlantoaxial optimal safe implantation corridors to generate objective recommendations for optimal implant placements and (2) to compare anatomical data obtained in non-affected Toy breed dogs, affected Toy breed dogs suffering from atlantoaxial instability and non-affected Beagle dogs. Methods  Anatomical data were collected from a prospectively recruited population of 27 dogs using a previously validated method of optimal safe implantation corridor analysis using computed tomographic images. Results  Optimal implant positions and three-dimensional numerical data were generated successfully in all cases. Anatomical landmarks could be used to generate objective definitions of optimal insertion points which were applicable across all three groups. Overall the geometrical distribution of all implant sites was similar in all three groups with a few exceptions. Clinical Significance  This study provides extensive anatomical data available to facilitate surgical planning of implant placement for atlantoaxial stabilization. Our data suggest that non-affected Toy breed dogs and non-affected Beagle dogs constitute reasonable research models to study atlantoaxial stabilization constructs. Schattauer GmbH Stuttgart.

  2. 3D Printing of Plant Golgi Stacks from Their Electron Tomographic Models.

    Science.gov (United States)

    Mai, Keith Ka Ki; Kang, Madison J; Kang, Byung-Ho

    2017-01-01

    Three-dimensional (3D) printing is an effective tool for preparing tangible 3D models from computer visualizations to assist in scientific research and education. With the recent popularization of 3D printing processes, it is now possible for individual laboratories to convert their scientific data into a physical form suitable for presentation or teaching purposes. Electron tomography is an electron microscopy method by which 3D structures of subcellular organelles or macromolecular complexes are determined at nanometer-level resolutions. Electron tomography analyses have revealed the convoluted membrane architectures of Golgi stacks, chloroplasts, and mitochondria. But the intricacy of their 3D organizations is difficult to grasp from tomographic models illustrated on computer screens. Despite the rapid development of 3D printing technologies, production of organelle models based on experimental data with 3D printing has rarely been documented. In this chapter, we present a simple guide to creating 3D prints of electron tomographic models of plant Golgi stacks using the two most accessible 3D printing technologies.

  3. Tomographic imaging of matter using primary and secondary X-and gamma-radiation

    International Nuclear Information System (INIS)

    Holloway, I.E.

    1991-04-01

    Gamma rays may interact with matter by a variety of processes, many of which give rise to secondary radiations. This thesis examines the possibility of performing tomographic imaging by means of these secondary photons using low-cost apparatus. The techniques are compared with each other and with transmission tomography, which plays such an important role in modern diagnostic imaging. The progress of industrial tomography is reviewed as are techniques of investigation using gamma ray scattering in both industry and medicine. Some new applications of a simple gamma ray computerized tomography (CT) scanner have been performed. A method of determining the spatial distribution of pure beta emitters in matter by performing tomographic imaging using the bremsstrahlung radiation produced by the beta particles has been demonstrated. This technique has been shown to permit imaging at depths in material greatly exceeding the range of beta particles in matter. All the imaging techniques using secondary radiation have displayed two principal limitations: long scanning times and poor quantitative accuracy. The low scanning rate results from the small number of secondary photons that are detected. The major contributing factors to poor accuracy are attenuation and the noise produced by unwanted in-scattering. The possible applications for secondary photon imaging have been briefly outlined and some suggestions for future work are included. Although techniques based upon imaging using secondary radiation will not be able to compete with transmission CT in the vast majority of applications, they may prove valuable in a range of specialised fields. (author)

  4. Development of a X-ray micro-tomograph and its application to reservoir rocks characterization

    International Nuclear Information System (INIS)

    Ferreira de Paiva, R.

    1995-10-01

    We describe the construction and application to studies in three dimensions of a laboratory micro-tomograph for the characterisation of heterogeneous solids at the scale of a few microns. The system is based on an electron microprobe and a two dimensional X-ray detector. The use of a low beam divergence for image acquisition allows use of simple and rapid reconstruction software whilst retaining reasonable acquisition times. Spatial resolutions of better than 3 microns in radiography and 10 microns in tomography are obtained. The applications of microtomography in the petroleum industry are illustrated by the study of fibre orientation in polymer composites, of the distribution of minerals and pore space in reservoir rocks, and of the interaction of salt water with a model porous medium. A correction for X-ray beam hardening is described and used to obtain improved discrimination of the phases present in the sample. In the case of a North Sea reservoir rock we show the possibility to distinguish quartz, feldspar and in certain zone kaolinite. The representativeness of the tomographic reconstruction is demonstrated by comparing the surface of the reconstructed specimen with corresponding images obtained in scanning electron microscopy. (author). 58 refs., 10 tabs., 71 photos

  5. Tomographic sensing and localization of fluorescently labeled circulating cells in mice in vivo

    International Nuclear Information System (INIS)

    Zettergren, Eric; Swamy, Tushar; Niedre, Mark; Runnels, Judith; Lin, Charles P

    2012-01-01

    Sensing and enumeration of specific types of circulating cells in small animals is an important problem in many areas of biomedical research. Microscopy-based fluorescence in vivo flow cytometry methods have been developed previously, but these are typically limited to sampling of very small blood volumes, so that very rare circulating cells may escape detection. Recently, we described the development of a ‘diffuse fluorescence flow cytometer’ (DFFC) that allows sampling of much larger blood vessels and therefore circulating blood volumes in the hindlimb, forelimb or tail of a mouse. In this work, we extend this concept by developing and validating a method to tomographically localize circulating fluorescently labeled cells in the cross section of a tissue simulating optical flow phantom and mouse limb. This was achieved using two modulated light sources and an array of six fiber-coupled detectors that allowed rapid, high-sensitivity acquisition of full tomographic data sets at 10 Hz. These were reconstructed into two-dimensional cross-sectional images using Monte Carlo models of light propagation and the randomized algebraic reconstruction technique. We were able to obtain continuous images of moving cells in the sample cross section with 0.5 mm accuracy or better. We first demonstrated this concept in limb-mimicking optical flow photons with up to four flow channels, and then in the tails of mice with fluorescently labeled multiple myeloma cells. This approach increases the overall diagnostic utility of our DFFC instrument. (paper)

  6. KiDS-450: tomographic cross-correlation of galaxy shear with Planck lensing

    Science.gov (United States)

    Harnois-Déraps, Joachim; Tröster, Tilman; Chisari, Nora Elisa; Heymans, Catherine; van Waerbeke, Ludovic; Asgari, Marika; Bilicki, Maciej; Choi, Ami; Erben, Thomas; Hildebrandt, Hendrik; Hoekstra, Henk; Joudaki, Shahab; Kuijken, Konrad; Merten, Julian; Miller, Lance; Robertson, Naomi; Schneider, Peter; Viola, Massimo

    2017-10-01

    We present the tomographic cross-correlation between galaxy lensing measured in the Kilo Degree Survey (KiDS-450) with overlapping lensing measurements of the cosmic microwave background (CMB), as detected by Planck 2015. We compare our joint probe measurement to the theoretical expectation for a flat Λ cold dark matter cosmology, assuming the best-fitting cosmological parameters from the KiDS-450 cosmic shear and Planck CMB analyses. We find that our results are consistent within 1σ with the KiDS-450 cosmology, with an amplitude re-scaling parameter AKiDS = 0.86 ± 0.19. Adopting a Planck cosmology, we find our results are consistent within 2σ, with APlanck = 0.68 ± 0.15. We show that the agreement is improved in both cases when the contamination to the signal by intrinsic galaxy alignments is accounted for, increasing A by ∼0.1. This is the first tomographic analysis of the galaxy lensing - CMB lensing cross-correlation signal, and is based on five photometric redshift bins. We use this measurement as an independent validation of the multiplicative shear calibration and of the calibrated source redshift distribution at high redshifts. We find that constraints on these two quantities are strongly correlated when obtained from this technique, which should therefore not be considered as a stand-alone competitive calibration tool.

  7. A study of the decoding of multiple pinhole coded aperture RI tomographic images

    International Nuclear Information System (INIS)

    Hasegawa, Takeo; Kobayashi, Akitoshi; Nishiyama, Yutaka

    1980-01-01

    The authors constructed a Multiple Pinhole Coded Aperture (MPCA) and developed related decoding software. When simple coordinate transformation was performed, omission of points and shifting of counts occurred. By selecting various tomographic planes and collecting count for each tomographic depth from the shadowgram, a solution to these problems was found. The counts from the central portion of the tomographic image from the MPCA were incorrectly high, this was rectified by a correction function to improve the uniformity correction program of the γ-camera. Depth resolution of the tomographic image improved in proportion to the area encompassed by the pinhole configuration. An MPCA with a uniform arrangement of pinholes (e, g, pinholes in an arrangement parallel to the X-axis or the Y-axis) yielded decoded tomographic images of inferior quality. Optimum results were obtained with a ring-shaped arrangement yielding clinically applicable tomographic images even for large objects. (author)

  8. Elective courses for medical students during the preclinical curriculum: a systematic review and evaluation

    Directory of Open Access Journals (Sweden)

    Ankit Agarwal

    2015-05-01

    Full Text Available Objective: Preclinical medical student electives are prevalent at medical schools across the United States, but the range of electives available and their impact on medical student education are not well described in the literature. The objective of this article is to review the literature relating to preclinical medical student electives and their impact on medical student educational outcomes. Methods: We reviewed studies that met the following criteria: English-language articles describing preclinical US-based medical electives. We used PubMed journal databases and limited our search for the time period 1999–2014. We excluded electives based in other countries or electives designed for third or fourth year students. Data abstracted included the topic of the elective, qualitative descriptions of the electives, and any associated surveys or exam data associated with the electives. Data were synthesized using descriptive tables sorting electives by broad topic. Reported outcomes and statistical methods were analyzed to assess study quality. Results: We found a wide range of subjects taught in the form of preclinical medical school electives. We identified electives in clinical skills, the humanities, student lifestyle, specialty-specific electives, and an assortment of other miscellaneous electives. Surveys and exams administered to students showed that the electives were universally well received by students. Of the 37 electives identified, 15 electives used quantitative objective assessments, such as knowledge exams, while the remaining tended to use student self-reported results. Conclusions: Preclinical medical student electives are prevalent at medical schools across the United States and have a significant impact on medical student education.

  9. Stem Cells for Cartilage Repair: Preclinical Studies and Insights in Translational Animal Models and Outcome Measures

    OpenAIRE

    Lo Monaco, Melissa; Merckx, Greet; Ratajczak, Jessica; Gervois, Pascal; Hilkens, Petra; Clegg, Peter; Bronckaers, Annelies; Vandeweerd, Jean-Michel; Lambrichts, Ivo

    2018-01-01

    Due to the restricted intrinsic capacity of resident chondrocytes to regenerate the lost cartilage postinjury, stem cell-based therapies have been proposed as a novel therapeutic approach for cartilage repair. Moreover, stem cell-based therapies using mesenchymal stem cells (MSCs) or induced pluripotent stem cells (iPSCs) have been used successfully in preclinical and clinical settings. Despite these promising reports, the exact mechanisms underlying stem cell-mediated cartilage repair remain...

  10. Anti-Correlated Cerebrospinal Fluid Biomarker Trajectories in Preclinical Alzheimer's Disease.

    Science.gov (United States)

    Gomar, Jesus J; Conejero-Goldberg, Concepcion; Davies, Peter; Goldberg, Terry E

    2016-01-01

    The earliest stage of preclinical Alzheimer's disease (AD) is defined by low levels of cerebrospinal fluid (CSF) amyloid-β (Aβ42). However, covariance in longitudinal dynamic change of Aβ42 and tau in incipient preclinical AD is poorly understood. To examine dynamic interrelationships between Aβ42 and tau in preclinical AD. We followed 47 cognitively intact participants (CI) with available CSF data over four years in ADNI. Based on longitudinal Aβ42 levels in CSF, CI were classified into three groups: 1) Aβ42 stable with normal levels of Aβ42 over time (n = 15); 2) Aβ42 declining with normal Aβ42 levels at baseline but showing decline over time (n = 14); and 3) Aβ42 levels consistently abnormal (n = 18). In the Aβ42 declining group, suggestive of incipient preclinical AD, CSF phosphorylated tau (p-tau) showed a similar longitudinal pattern of increasing abnormality over time (p = 0.0001). Correlation between longitudinal slopes of Aβ42 and p-tau confirmed that both trajectories were anti-correlated (rho = -0.60; p = 0.02). Regression analysis showed that Aβ42 slope (decreasing Aβ42) predicted p-tau slope (increasing p-tau) (R2 = 0.47, p = 0.03). Atrophy in the hippocampus was predicted by the interaction of Aβ42 and p-tau slopes (p anti-correlated trajectory, i.e., as Aβ42 declined, p-tau increased, and thus was suggestive of strong temporal coincidence. Rapid pathogenic cross-talk between Aβ42 and p-tau thus may be evident in very early stages of preclinical AD.

  11. Tomographic image reconstruction using Artificial Neural Networks

    International Nuclear Information System (INIS)

    Paschalis, P.; Giokaris, N.D.; Karabarbounis, A.; Loudos, G.K.; Maintas, D.; Papanicolas, C.N.; Spanoudaki, V.; Tsoumpas, Ch.; Stiliaris, E.

    2004-01-01

    A new image reconstruction technique based on the usage of an Artificial Neural Network (ANN) is presented. The most crucial factor in designing such a reconstruction system is the network architecture and the number of the input projections needed to reconstruct the image. Although the training phase requires a large amount of input samples and a considerable CPU time, the trained network is characterized by simplicity and quick response. The performance of this ANN is tested using several image patterns. It is intended to be used together with a phantom rotating table and the γ-camera of IASA for SPECT image reconstruction

  12. Posterior variability of inclusion shape based on tomographic measurement data

    International Nuclear Information System (INIS)

    Watzenig, Daniel; Fox, Colin

    2008-01-01

    We treat the problem of recovering the unknown shape of a single inclusion with unknown constant permittivity in an otherwise uniform background material, from uncertain measurements of trans-capacitance at electrodes outside the material. The ubiquitous presence of measurement noise implies that the practical measurement process is probabilistic, and the inverse problem is naturally stated as statistical inference. Formulating the inverse problem in a Bayesian inferential framework requires accurately modelling the forward map, measurement noise, and specifying a prior distribution for the cross-sectional material distribution. Numerical implementation of the forward map is via the boundary element method (BEM) taking advantage of a piecewise constant representation. Summary statistics are calculated using MCMC sampling to characterize posterior variability for synthetic and measured data sets.

  13. Computed tomographic appearance of resectable pancreatic carcinoma

    International Nuclear Information System (INIS)

    Itai, Y.; Araki, T.; Tasaka, A.; Maruyama, M.

    1982-01-01

    Thirteen patients with resectable pancreatic carcinoma were examined by computed tomography (CT). Nine had a mass, 2 had dilatation of the main pancreatic duct, 1 appeared to have ductal dilatation, and 1 had no sign of abnormality. Resectable carcinoma was diagnosed retrospectively in 8 cases, based on the following criteria: a mass with a distinct contour, frequently containing a tiny or irregular low-density area and accompanied by dilatation of the caudal portion of the main pancreatic duct without involvement of the large vessels, liver, or lymph nodes. Including unresectable cancer, chronic pancreatitis, and obstructive jaundice from causes other than cancer, the false-positive rate was less than 6%. However, a small cancer without change in pancreatic contour is difficult to detect with CT

  14. Segmentation Toolbox for Tomographic Image Data

    DEFF Research Database (Denmark)

    Einarsdottir, Hildur

    , techniques to automatically analyze such data becomes ever more important. Most segmentation methods for large datasets, such as CT images, deal with simple thresholding techniques, where intensity values cut offs are predetermined and hard coded. For data where the intensity difference is not sufficient......Motivation: Image acquisition has vastly improved over the past years, introducing techniques such as X-ray computed tomography (CT). CT images provide the means to probe a sample non-invasively to investigate its inner structure. Given the wide usage of this technique and massive data amounts......, and partial volume voxels occur frequently, thresholding methods do not suffice and more advanced methods are required. Contribution: To meet these requirements a toolbox has been developed, combining well known methods within the image analysis field. The toolbox includes cluster-based methods...

  15. Preclinical Alzheimer disease and risk of falls.

    Science.gov (United States)

    Stark, Susan L; Roe, Catherine M; Grant, Elizabeth A; Hollingsworth, Holly; Benzinger, Tammie L; Fagan, Anne M; Buckles, Virginia D; Morris, John C

    2013-07-30

    We determined the rate of falls among cognitively normal, community-dwelling older adults, some of whom had presumptive preclinical Alzheimer disease (AD) as detected by in vivo imaging of fibrillar amyloid plaques using Pittsburgh compound B (PiB) and PET and/or by assays of CSF to identify Aβ₄₂, tau, and phosphorylated tau. We conducted a 12-month prospective cohort study to examine the cumulative incidence of falls. Participants were evaluated clinically and underwent PiB PET imaging and lumbar puncture. Falls were reported monthly using an individualized calendar journal returned by mail. A Cox proportional hazards model was used to test whether time to first fall was associated with each biomarker and the ratio of CSF tau/Aβ₄₂ and CSF phosphorylated tau/Aβ₄₂, after adjustment for common fall risk factors. The sample (n = 125) was predominately female (62.4%) and white (96%) with a mean age of 74.4 years. When controlled for ability to perform activities of daily living, higher levels of PiB retention (hazard ratio = 2.95 [95% confidence interval 1.01-6.45], p = 0.05) and of CSF biomarker ratios (p risk factor for falls in older adults. This study suggests that subtle noncognitive changes that predispose older adults to falls are associated with AD and may precede detectable cognitive changes.

  16. [Preclinical horizon of depression in adults].

    Science.gov (United States)

    Jiménez-Báez, María Valeria; Márquez-González, Horacio; Monsreal-Góngora, Juan Leonardo; Góngora-González, Gonzalo; Sandoval-Jurado, Luis; Boquer-Hernández, Rubén

    2016-01-01

    Identify factors related to preclinical depression in healthy adults, their risk factors and concordance with family doctor diagnostic. Case-control study in adult from family medicine consulting room. Beck inventory for depression was applied. The correlation between depression and the diagnosis by the family physician was evaluated. Odds ratio (OR) was determined. Involved 138 patients randomly from four family medicine units (FMU) in the Northern Region of Quintana Roo, Mexico. The mean age 34.9 ± 11.4 years, 55.8% women, prevalence for depression was 26.1%. Being male OR: 3.76; 95% CI: 1.69-8.36, under 30 years OR: 2.76; 95% CI: 1.27-5.99, low socioeconomic status (SES) OR: 2.11; 95% CI: 0.97-4.59 and be married OR: 3.22; 95% CI: 1.41.-7.36 had depression risk. Diagnosis by the family physician and inventory Beck. Kappa Index 0.2, 95% CI: -0057-0176; p = 0.05. Almost a third of young adults have some depression degree in family medicine consulting room, it is necessary a depression screening for male patients, low SES, married, and under 30 years old, attending medical consultation familiar, for a early diagnosis and improve prognosis.

  17. Time management for preclinical safety professionals.

    Science.gov (United States)

    Wells, Monique Y

    2010-08-01

    A survey about time management in the workplace was distributed to obtain a sense of the level of job satisfaction among preclinical safety professionals in the current economic climate, and to encourage reflection upon how we manage time in our work environment. Roughly equal numbers of respondents (approximately 32%) identified themselves as management or staff, and approximately 27% indicated that they are consultants. Though 45.2% of respondents indicated that time management is very challenging for the profession in general, only 36.7% find it very challenging for themselves. Ten percent of respondents view time management to be exceedingly challenging for themselves. Approximately 34% of respondents indicated that prioritization of tasks was the most challenging aspect of time management for them. Focusing on an individual task was the second most challenging aspect (26%), followed equally by procrastination and delegation of tasks (12.4%). Almost equal numbers of respondents said that they would (35.2%) or might (33.3%) undertake training to improve their time management skills. Almost equal numbers of participants responded "perhaps" (44.6%) or "yes" (44.2%) to the question of whether management personnel should be trained in time management.

  18. Detection of preclinical Parkinson's disease with PET

    International Nuclear Information System (INIS)

    Brooks, D.J.

    1991-01-01

    Putamen 18F-dopa uptake of patients with Parkinson's disease (PD) is reduced by at least 35% at onset of symptoms; therefore, positron-emission tomography (PET) can be used to detect preclinical disease in clinically unaffected twins and relatives of patients with PD. Three out of 6 monozygotic and 2 out of 3 dizygotic unaffected PD co-twins have shown reduced putamen 18F-dopa uptake to date. In addition, an intact sibling and a daughter of 1 of 4 siblings with PD both had low putamen 18F-dopa uptake. These preliminary findings suggest there may be a familial component to the etiology of PD. PET can also be used to detect underlying nigral pathology in patients with isolated tremor and patients who become rigid taking dopamine-receptor blocking agents (DRBAs). Patients with familial essential tremor have normal, and those with isolated rest tremor have consistently low, putamen 18F-dopa uptake. Drug-induced parkinsonism is infrequently associated with underlying nigral pathology

  19. Quetiapine: recent developments in preclinical research

    Directory of Open Access Journals (Sweden)

    Marco Orsetti

    2010-03-01

    Full Text Available Quetiapine (QTP is an atypical antipsychotic labelled for the treatment of patients with schizophrenia, bipolar mania and bipolar depression. Nevertheless, QTP has been tried across multiple diagnosis categories and seems to be used, among other atypical antipsychotics, in clinical practice for an expanding range of disorders such as major depression, substance abuse disorders, anxiety disorders, and borderline personality disorders. The present review focuses on papers which investigated the molecular mechanism(s of QTP antidepressant effect. In particular, preclinical studies performed by coupling the chronic mild stress, an animal model of human depression with Affymetrix microarray technology, revealed that chronic QTP administration prevented the stress-induced up- or down-regulation of 42 genes involved in the central nervous system development or having a crucial role for viability of neural cells, like regulation of signal transduction, inorganic ion transport, membrane organisation, and neurite morphogenesis. Among these, Ptgs2, Hes5, Plcb1, Senp2, Gad1, and Marcks are presumably the effectors of the QTP clinical efficacy.

  20. Preclinical animal anxiety research - flaws and prejudices.

    Science.gov (United States)

    Ennaceur, Abdelkader; Chazot, Paul L

    2016-04-01

    The current tests of anxiety in mice and rats used in preclinical research include the elevated plus-maze (EPM) or zero-maze (EZM), the light/dark box (LDB), and the open-field (OF). They are currently very popular, and despite their poor achievements, they continue to exert considerable constraints on the development of novel approaches. Hence, a novel anxiety test needs to be compared with these traditional tests, and assessed against various factors that were identified as a source of their inconsistent and contradictory results. These constraints are very costly, and they are in most cases useless as they originate from flawed methodologies. In the present report, we argue that the EPM or EZM, LDB, and OF do not provide unequivocal measures of anxiety; that there is no evidence of motivation conflict involved in these tests. They can be considered at best, tests of natural preference for unlit and/or enclosed spaces. We also argued that pharmacological validation of a behavioral test is an inappropriate approach; it stems from the confusion of animal models of human behavior with animal models of pathophysiology. A behavioral test is developed to detect not to produce symptoms, and a drug is used to validate an identified physiological target. In order to overcome the major methodological flaws in animal anxiety studies, we proposed an open space anxiety test, a 3D maze, which is described here with highlights of its various advantages over to the traditional tests.

  1. Dense velocity reconstruction from tomographic PTV with material derivatives

    Science.gov (United States)

    Schneiders, Jan F. G.; Scarano, Fulvio

    2016-09-01

    A method is proposed to reconstruct the instantaneous velocity field from time-resolved volumetric particle tracking velocimetry (PTV, e.g., 3D-PTV, tomographic PTV and Shake-the-Box), employing both the instantaneous velocity and the velocity material derivative of the sparse tracer particles. The constraint to the measured temporal derivative of the PTV particle tracks improves the consistency of the reconstructed velocity field. The method is christened as pouring time into space, as it leverages temporal information to increase the spatial resolution of volumetric PTV measurements. This approach becomes relevant in cases where the spatial resolution is limited by the seeding concentration. The method solves an optimization problem to find the vorticity and velocity fields that minimize a cost function, which includes next to instantaneous velocity, also the velocity material derivative. The velocity and its material derivative are related through the vorticity transport equation, and the cost function is minimized using the limited-memory Broyden-Fletcher-Goldfarb-Shanno (L-BFGS) algorithm. The procedure is assessed numerically with a simulated PTV experiment in a turbulent boundary layer from a direct numerical simulation (DNS). The experimental validation considers a tomographic particle image velocimetry (PIV) experiment in a similar turbulent boundary layer and the additional case of a jet flow. The proposed technique (`vortex-in-cell plus', VIC+) is compared to tomographic PIV analysis (3D iterative cross-correlation), PTV interpolation methods (linear and adaptive Gaussian windowing) and to vortex-in-cell (VIC) interpolation without the material derivative. A visible increase in resolved details in the turbulent structures is obtained with the VIC+ approach, both in numerical simulations and experiments. This results in a more accurate determination of the turbulent stresses distribution in turbulent boundary layer investigations. Data from a jet

  2. Tomographic reconstruction with B-splines surfaces

    International Nuclear Information System (INIS)

    Oliveira, Eric F.; Dantas, Carlos C.; Melo, Silvio B.; Mota, Icaro V.; Lira, Mailson

    2011-01-01

    Algebraic reconstruction techniques when applied to a limited number of data usually suffer from noise caused by the process of correction or by inconsistencies in the data coming from the stochastic process of radioactive emission and oscillation equipment. The post - processing of the reconstructed image with the application of filters can be done to mitigate the presence of noise. In general these processes also attenuate the discontinuities present in edges that distinguish objects or artifacts, causing excessive blurring in the reconstructed image. This paper proposes a built-in noise reduction at the same time that it ensures adequate smoothness level in the reconstructed surface, representing the unknowns as linear combinations of elements of a piecewise polynomial basis, i.e. a B-splines basis. For that, the algebraic technique ART is modified to accommodate the first, second and third degree bases, ensuring C 0 , C 1 and C 2 smoothness levels, respectively. For comparisons, three methodologies are applied: ART, ART post-processed with regular B-splines filters (ART*) and the proposed method with the built-in B-splines filter (BsART). Simulations with input data produced from common mathematical phantoms were conducted. For the phantoms used the BsART method consistently presented the smallest errors, among the three methods. This study has shown the superiority of the change made to embed the filter in the ART when compared to the post-filtered ART. (author)

  3. Computed tomographic study of aged schizophrenic patients

    International Nuclear Information System (INIS)

    Seno, Haruo; Fujimoto, Akihiko; Ishino, Hiroshi; Shibata, Masahiro; Kuroda, Hiroyuki; Kanno, Hiroshi.

    1997-01-01

    The width of interhemispheric fissure, lateral ventricles and third ventricle were measured using cranial computed tomography (CT; linear method) in 45 elderly inpatients with chronic schizophrenia and in 28 age-matched control subjects. Twenty-three patients were men and 22 were women. In addition, Mini-Mental State Examination, Brief Psychiatric Rating Scale (BPRS) and a subclass of BPRS were undertaken in all patients. There is a significant enlargement of the maximum width of the interhemispheric fissure (in both male and female) and a significant enlargement of ventricular system (more severe in men than in women) in aged schizophrenics, as seen with CT, compared with normal controls. These findings are consistent with previous studies of non-aged schizophrenic patients. Based upon the relation between psychiatric symptoms and CT findings, the most striking is a significant negative correlation between the third ventricle enlargement and the positive and depressive symptoms in all patients. This result suggests that the advanced third ventricle enlargement may decrease these symptoms in aged schizophrenics. (author)

  4. Optical tomographic imaging for breast cancer detection

    Science.gov (United States)

    Cong, Wenxiang; Intes, Xavier; Wang, Ge

    2017-09-01

    Diffuse optical breast imaging utilizes near-infrared (NIR) light propagation through tissues to assess the optical properties of tissues for the identification of abnormal tissue. This optical imaging approach is sensitive, cost-effective, and does not involve any ionizing radiation. However, the image reconstruction of diffuse optical tomography (DOT) is a nonlinear inverse problem and suffers from severe illposedness due to data noise, NIR light scattering, and measurement incompleteness. An image reconstruction method is proposed for the detection of breast cancer. This method splits the image reconstruction problem into the localization of abnormal tissues and quantification of absorption variations. The localization of abnormal tissues is performed based on a well-posed optimization model, which can be solved via a differential evolution optimization method to achieve a stable reconstruction. The quantification of abnormal absorption is then determined in localized regions of relatively small extents, in which a potential tumor might be. Consequently, the number of unknown absorption variables can be greatly reduced to overcome the underdetermined nature of DOT. Numerical simulation experiments are performed to verify merits of the proposed method, and the results show that the image reconstruction method is stable and accurate for the identification of abnormal tissues, and robust against the measurement noise of data.

  5. ULTRASOUND AND COMPUTED TOMOGRAPHIC DIAGNOSIS OF OPTIC NERVE TUMORS

    Directory of Open Access Journals (Sweden)

    S. V. Saakyan

    2012-01-01

    Full Text Available A comprehensive examination was made in 93 patients, including 18 children, with tumors of the optic nerve (ON. Duplex ultrasound scanning was performed in 39 patients, of them there were 11 patients with ON gliomas and 28 with ON meningiomas. The specific computed tomographic and echographic signs of ON glioma and meningiomas were detected. The studies have shown that duplex ultrasound scanning and structural computed tomography of orbital sockets are highly informative complementary imaging procedures for ON tumors, which permits one to make their correct diagnosis, to specify surgical volume, and to plan adequate treatment.

  6. Tomographic elastography of contracting skeletal muscles from their natural vibrations

    Science.gov (United States)

    Sabra, Karim G.; Archer, Akibi

    2009-11-01

    Conventional elastography techniques require an external mechanical or radiation excitation to measure noninvasively the viscoelastic properties of skeletal muscles and thus monitor human motor functions. We developed instead a passive elastography technique using only an array of skin-mounted accelerometers to record the low-frequency vibrations of the biceps brachii muscle naturally generated during voluntary contractions and to determine their two-dimensional directionality. Cross-correlating these recordings provided travel-times measurements of these muscle vibrations between multiple sensor pairs. Travel-time tomographic inversions yielded spatial variations of their propagation velocity during isometric elbow flexions which indicated a nonuniform longitudinal stiffening of the biceps.

  7. Gas microstrip detectors for X-ray tomographic flow imaging

    CERN Document Server

    Key, M J; Luggar, R D; Kundu, A

    2003-01-01

    A investigation into the suitability of gas microstrip detector technology for a high-speed industrial X-ray tomography system is reported. X-ray energies in the region 20-30 keV are well suited to the application, which involves imaging two-dimensional slices through gas/liquid multiphase pipeline flows for quantitative component fraction measurement. Stable operation over a period representing several hundred individual tomographic scans at gas gains of 500 is demonstrated using a Penning gas mixture of krypton/propylene.

  8. Development of the Shimadzu computed tomographic scanner SCT-200N

    International Nuclear Information System (INIS)

    Ishihara, Hiroshi; Yamaoka, Nobuyuki; Saito, Masahiro

    1982-01-01

    The Shimadzu Computed Tomographic Scanner SCT-200N has been developed as an ideal CT scanner for diagnosing the head and spine. Due to the large aperture, moderate scan time and the Zoom Scan Mode, any part of the body can be scanned. High quality image can be obtained by adopting the precisely stabilized X-ray unit and densely packed array of 64-detectors. As for its operation, capability of computed radiography (CR) prior to patient positioning and real time reconstruction ensure efficient patient through-put. Details of the SCT-200N are described in this paper. (author)

  9. Design of a volume-imaging positron emission tomograph

    International Nuclear Information System (INIS)

    Harrop, R.; Rogers, J.G.; Coombes, G.H.; Wilkinson, N.A.; Pate, B.D.; Morrison, K.S.; Stazyk, M.; Dykstra, C.J.; Barney, J.S.; Atkins, M.S.; Doherty, P.W.; Saylor, D.P.

    1988-11-01

    Progress is reported in several areas of design of a positron volume imaging tomograph. As a means of increasing the volume imaged and the detector packing fraction, a lens system of detector light coupling is considered. A prototype layered scintillator detector demonstrates improved spatial resolution due to a unique Compton rejection capability. The conceptual design of a new mechanism for measuring scattered radiation during emission scans has been tested by Monte Carlo simulation. The problem of how to use effectively the resulting sampled scattered radiation projections is presented and discussed

  10. Computed tomographic spectrum of intracranial mycosis: correlation with histopathology

    International Nuclear Information System (INIS)

    Whelan, M.A.; Stern, J.; deNapoli, R.A.

    1981-01-01

    Four cases of intracerebral fungal infection are reviewed. The clinical course is outlined, and the computed tomographic (CT) characteristics are analyzed in light of known pathological data. The CT appearance of intracranial mycosis is dependent on the type of fungus as well as the dominant infecting form, i.e., yeast or hyphae. The hyphal form leads predominantly to a CT pattern consistent with vascular occlusion and secondary abscess formation; the yeast form generally results in noncaseating granulomas, which appear on CT scan as nodular enhancing lesions. If the patient survives the acute infective process, these fungal lesions undergo a prolonged subacute phase, and may eventually calcify

  11. Direct computation of harmonic moments for tomographic reconstruction

    International Nuclear Information System (INIS)

    Nara, Takaaki; Ito, Nobutaka; Takamatsu, Tomonori; Sakurai, Tetsuya

    2007-01-01

    A novel algorithm to compute harmonic moments of a density function from its projections is presented for tomographic reconstruction. For projection p(r, θ), we define harmonic moments of projection by ∫ π 0 ∫ ∞ -∞ p(r,θ)(re iθ ) n drd θ and show that it coincides with the harmonic moments of the density function except a constant. Furthermore, we show that the harmonic moment of projection of order n can be exactly computed by using n+ 1 projection directions, which leads to an efficient algorithm to reconstruct the vertices of a polygon from projections.

  12. 4-D tomographic monitoring of enhanced oil recovery

    International Nuclear Information System (INIS)

    Brzostowski, M.A.; McMechan, G.A.

    1991-01-01

    One application of tomography that has recently received considerable attention is reservoir monitoring for Enhanced Oil Recovery (EOR). Tomographic monitoring of a moving steam front uses the significant decrease in compressional wave velocity that occurs as hydrocarbon temperature increases. The purposes of this paper are to present a working algorithm for 3-D tomography, to demonstrate the feasibility of 3-D imaging of a simulated reservoir in which the position of a steam front changes with time, and to illustrate the relations between survey geometry and the resolution of the target

  13. Non tumoral intracranial expansive processes: clinical tomographic correlation

    International Nuclear Information System (INIS)

    Campos, P.; Herrera, G.; Valneica, F.

    1991-01-01

    Presentation of clinical-tomographic correlation in 111 cases of non tumoral intracranial expansive processes seen between 1984-1988 in the Hospital Cayetano Heredia (Lima, Peru). Emphasis is given fundamentally to: the importance of establishing the organicity of partial and late epilepsy; the high incidence rate of inflammatory infectious processes with CNS compromise in under developing countries; the necessity of making public the importance of two parasitic diseases in the differential diagnosis of non tumoral intracranial expansive processes: free living amebiasis, and toxoplasmosis (especially in association with AIDS). (author)

  14. 3D Tomographic Image Reconstruction using CUDA C

    International Nuclear Information System (INIS)

    Dominguez, J. S.; Assis, J. T.; Oliveira, L. F. de

    2011-01-01

    This paper presents the study and implementation of a software for three dimensional reconstruction of images obtained with a tomographic system using the capabilities of Graphic Processing Units(GPU). The reconstruction by filtered back-projection method was developed using the CUDA C, for maximum utilization of the processing capabilities of GPUs to solve computational problems with large computational cost and highly parallelizable. It was discussed the potential of GPUs and shown its advantages to solving this kind of problems. The results in terms of runtime will be compared with non-parallelized implementations and must show a great reduction of processing time. (Author)

  15. Wireless Handheld Computers in the Preclinical Undergraduate Curriculum

    Directory of Open Access Journals (Sweden)

    Matt Jackson

    2003-02-01

    Full Text Available This report presents the results of a pilot project using wireless PDAs as teaching tools in an undergraduate medical curriculum. This technology was used to foster a transition from a passive to an interactive learning environment in the classroom and provided a solution for the implementation of computer-based exams for a large class. Wayne State Medical School recently provided model e570 Toshiba PocketPCs® (personal digital assistants or PDAs, network interface cards, and application software developed by CampusMobility® to 20 sophomore medical students. The pilot group of preclinical students used the PDAs to access web-based course content, for communication, scheduling, to participate in interactive teaching sessions, and to complete course evaluations. Another part of this pilot has been to utilize the PDAs for computer-based exams in a wireless environment. Server authentication that restricted access during the exams and a proctoring console to monitor and record the PDA screens will be described in this report. Results of a student satisfaction survey will be presented.

  16. Preclinical efficacy and safety of herbal formulation for management ...

    African Journals Online (AJOL)

    Preclinical efficacy and safety of herbal formulation for management of wounds. ... The effects of the treatments on rate of wound closure, epithelialisation time ... inflammation and better tissue remodeling for rats treated with herbal product.

  17. The role of radiolabelled compounds in preclinical drug development

    International Nuclear Information System (INIS)

    Hawkins, D.R.

    1988-01-01

    The role of radiolabelled compounds in the development of new drugs is discussed, with particular reference to their use in toxicological, metabolic and pharmacokinetic studies for the pre-clinical safety evaluation of new drugs. (U.K.)

  18. A computed tomographic study on epilepsy

    International Nuclear Information System (INIS)

    Bae, Hoon Sik

    1980-01-01

    history revealed more abnormal findings than the patients with over 6 months of history. And most of the abnormal findings in the latter were atrophic lesion. 50% of patients with primary generalized seizure and 54.5% of patients with partial seizure revealed abnormal findings on CT. 9. EEG was done in 41 cases. 23 out of 41 patients revealed normal CT and 18 patients revealed abnormal CT. In patients with normal EEG, 9 patients revealed abnormal findings on CT. 8 out of those 9 patients showed focal low density. So there was no significant correlation between EEG and CT. 10. Most of the lesions on CT were located in the supratentorial region, particularly in the frontal and parietal lobe. There were patients who had lesions in the posterior fossa, one in the brain stem and the other in the vermis. 11. The diagnosis based on the CT finidnigs included brain tumor (9.3%), cerebral infarct (7.9%), granuloma (5.7%), cortical atrophy (5%), and calcification (5%) respectively.

  19. A computed tomographic study on epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Hoon Sik [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    1980-06-15

    history revealed more abnormal findings than the patients with over 6 months of history. And most of the abnormal findings in the latter were atrophic lesion. 50% of patients with primary generalized seizure and 54.5% of patients with partial seizure revealed abnormal findings on CT. 9. EEG was done in 41 cases. 23 out of 41 patients revealed normal CT and 18 patients revealed abnormal CT. In patients with normal EEG, 9 patients revealed abnormal findings on CT. 8 out of those 9 patients showed focal low density. So there was no significant correlation between EEG and CT. 10. Most of the lesions on CT were located in the supratentorial region, particularly in the frontal and parietal lobe. There were patients who had lesions in the posterior fossa, one in the brain stem and the other in the vermis. 11. The diagnosis based on the CT finidnigs included brain tumor (9.3%), cerebral infarct (7.9%), granuloma (5.7%), cortical atrophy (5%), and calcification (5%) respectively.

  20. Rigor or mortis: best practices for preclinical research in neuroscience.

    Science.gov (United States)

    Steward, Oswald; Balice-Gordon, Rita

    2014-11-05

    Numerous recent reports document a lack of reproducibility of preclinical studies, raising concerns about potential lack of rigor. Examples of lack of rigor have been extensively documented and proposals for practices to improve rigor are appearing. Here, we discuss some of the details and implications of previously proposed best practices and consider some new ones, focusing on preclinical studies relevant to human neurological and psychiatric disorders. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Deformable 3D–2D registration for CT and its application to low dose tomographic fluoroscopy

    International Nuclear Information System (INIS)

    Flach, Barbara; Brehm, Marcus; Sawall, Stefan; Kachelrieß, Marc

    2014-01-01

    Many applications in medical imaging include image registration for matching of images from the same or different modalities. In the case of full data sampling, the respective reconstructed images are usually of such a good image quality that standard deformable volume-to-volume (3D–3D) registration approaches can be applied. But research in temporal-correlated image reconstruction and dose reductions increases the number of cases where rawdata are available from only few projection angles. Here, deteriorated image quality leads to non-acceptable deformable volume-to-volume registration results. Therefore a registration approach is required that is robust against a decreasing number of projections defining the target position. We propose a deformable volume-to-rawdata (3D–2D) registration method that aims at finding a displacement vector field maximizing the alignment of a CT volume and the acquired rawdata based on the sum of squared differences in rawdata domain. The registration is constrained by a regularization term in accordance with a fluid-based diffusion. Both cost function components, the rawdata fidelity and the regularization term, are optimized in an alternating manner. The matching criterion is optimized by a conjugate gradient descent for nonlinear functions, while the regularization is realized by convolution of the vector fields with Gaussian kernels. We validate the proposed method and compare it to the demons algorithm, a well-known 3D–3D registration method. The comparison is done for a range of 4–60 target projections using datasets from low dose tomographic fluoroscopy as an application example. The results show a high correlation to the ground truth target position without introducing artifacts even in the case of very few projections. In particular the matching in the rawdata domain is improved compared to the 3D–3D registration for the investigated range. The proposed volume-to-rawdata registration increases the robustness

  2. Development of the two Korean adult tomographic computational phantoms for organ dosimetry

    International Nuclear Information System (INIS)

    Lee, Choonsik; Lee, Choonik; Park, Sang-Hyun; Lee, Jai-Ki

    2006-01-01

    Following the previously developed Korean tomographic phantom, KORMAN, two additional whole-body tomographic phantoms of Korean adult males were developed from magnetic resonance (MR) and computed tomography (CT) images, respectively. Two healthy male volunteers, whose body dimensions were fairly representative of the average Korean adult male, were recruited and scanned for phantom development. Contiguous whole body MR images were obtained from one subject exclusive of the arms, while whole-body CT images were acquired from the second individual. A total of 29 organs and tissues and 19 skeletal sites were segmented via image manipulation techniques such as gray-level thresholding, region growing, and manual drawing, in which each of segmented image slice was subsequently reviewed by an experienced radiologist for anatomical accuracy. The resulting phantoms, the MR-based KTMAN-1 (Korean Typical MAN-1) and the CT-based KTMAN-2 (Korean Typical MAN-2), consist of 300x150x344 voxels with a voxel resolution of 2x2x5 mm 3 for both phantoms. Masses of segmented organs and tissues were calculated as the product of a nominal reference density, the prevoxel volume, and the cumulative number of voxels defining each organs or tissue. These organs masses were then compared with those of both the Asian and the ICRP reference adult male. Organ masses within both KTMAN-1 and KTMAN-2 showed differences within 40% of Asian and ICRP reference values, with the exception of the skin, gall bladder, and pancreas which displayed larger differences. The resulting three-dimensional binary file was ported to the Monte Carlo code MCNPX2.4 to calculate organ doses following external irradiation for illustrative purposes. Colon, lung, liver, and stomach absorbed doses, as well as the effective dose, for idealized photon irradiation geometries (anterior-posterior and right lateral) were determined, and then compared with data from two other tomographic phantoms (Asian and Caucasian), and

  3. Pre-clinical evaluation of extracts and essential oils from betel-like ...

    African Journals Online (AJOL)

    The extracts and oils were preclinically studied based on cyto - and genotoxicity using microculture tetrazolium (MTT) and comet assays. Results: The crude extracts showed an IC50 in leukocytes and HeLa cells of 58.59 -97.31 mg/ml and 34.91-101.79 mg/ml, the LD50 is higher than 5000 mg/kg. With lower values than the ...

  4. Implementation of Japanese male and female tomographic phantoms to multi-particle Monte Carlo code for ionizing radiation dosimetry

    International Nuclear Information System (INIS)

    Lee, Choonsik; Nagaoka, Tomoaki; Lee, Jai-Ki

    2006-01-01

    phantoms for other irradiation geometries should be carried by employing additional tomographic phantoms to find out the dosimetric difference of Asian human phantoms from Caucasian-based phantoms. (author)

  5. Study partners should be required in preclinical Alzheimer's disease trials.

    Science.gov (United States)

    Grill, Joshua D; Karlawish, Jason

    2017-12-06

    In an effort to intervene earlier in Alzheimer's disease (AD), clinical trials are testing promising candidate therapies in preclinical disease. Preclinical AD trial participants are cognitively normal, functionally independent, and autonomous decision-makers. Yet, like AD dementia trials, preclinical trials require dual enrollment of a participant and a knowledgeable informant, or study partner. The requirement of dyadic enrollment is a barrier to recruitment and may present unique ethical challenges. Despite these limitations, the requirement should continue. Study partners may be essential to ensure participant safety and wellbeing, including overcoming distress related to biomarker disclosure and minimizing risk for catastrophic reactions and suicide. The requirement may maximize participant retention and ensure data integrity, including that study partners are the source of data that will ultimately instruct whether a new treatment has a clinical benefit and meaningful impact on the population health burden associated with AD. Finally, study partners are needed to ensure the scientific and clinical value of trials. Preclinical AD will represent a new model of care, in which persons with no symptoms are informed of probable cognitive decline and eventual dementia. The rationale for early diagnosis in symptomatic AD is equally applicable in preclinical AD-to minimize risk, maximize quality of life, and ensure optimal planning and communication. Family members and other sources of support will likely be essential to the goals of this new model of care for preclinical AD patients and trials must instruct this clinical practice.

  6. Tomographic Reconstruction from a Few Views: A Multi-Marginal Optimal Transport Approach

    Energy Technology Data Exchange (ETDEWEB)

    Abraham, I., E-mail: isabelle.abraham@cea.fr [CEA Ile de France (France); Abraham, R., E-mail: romain.abraham@univ-orleans.fr; Bergounioux, M., E-mail: maitine.bergounioux@univ-orleans.fr [Université d’Orléans, UFR Sciences, MAPMO, UMR 7349 (France); Carlier, G., E-mail: carlier@ceremade.dauphine.fr [CEREMADE, UMR CNRS 7534, Université Paris IX Dauphine, Pl. de Lattre de Tassigny (France)

    2017-02-15

    In this article, we focus on tomographic reconstruction. The problem is to determine the shape of the interior interface using a tomographic approach while very few X-ray radiographs are performed. We use a multi-marginal optimal transport approach. Preliminary numerical results are presented.

  7. Does student performance on preclinical OSCEs relate to clerkship grades?

    Directory of Open Access Journals (Sweden)

    Margot Chima

    2016-06-01

    Full Text Available Background: Objective structured clinical examinations (OSCEs have been used to assess the clinical competence and interpersonal skills of healthcare professional students for decades. However, the relationship between preclinical (second year or M2 OSCE grades and clerkship performance had never been evaluated, until it was explored to provide information to educators at the University of Nebraska Medical Center (UNMC. In addition, the relationship between M2 OSCE communication scores (which is a portion of the total score and third-year (M3 Internal Medicine (IM clerkship OSCE scores was also explored. Lastly, conflicting evidence exists about the relationship between the amount of previous clinical experience and OSCE performance. Therefore, the relationship between M3 IM clerkship OSCE scores and the timing of the clerkship in the academic year was explored. Methods: Data from UNMC M2 OSCEs and M3 IM clerkship OSCEs were obtained for graduates of the 2013 and 2014 classes. Specifically, the following data points were collected: M2 fall OSCE total, M2 fall OSCE communication; M2 spring OSCE total, M2 spring OSCE communication; and M3 IM clerkship OSCE total percentages. Data were organized by class, M3 IM clerkship OSCE performance, and timing of the clerkship. Microsoft Excel and SPSS were used for data organization and analysis. Results: Of the 245 records, 229 (93.5% had data points for all metrics of interest. Significant differences between the classes of 2013 and 2014 existed for average M2 spring total, M2 spring communication, and M3 IM clerkship OSCEs. Retrospectively, there were no differences in M2 OSCE performances based on how students scored on the M3 IM clerkship OSCE. M3 IM clerkship OSCE performance improved for those students who completed the clerkship last in the academic year. Conclusions: There were inconsistencies in OSCE performances between the classes of 2013 and 2014, but more information is needed to determine if

  8. Does student performance on preclinical OSCEs relate to clerkship grades?

    Science.gov (United States)

    Chima, Margot; Dallaghan, Gary Beck

    2016-01-01

    Objective structured clinical examinations (OSCEs) have been used to assess the clinical competence and interpersonal skills of healthcare professional students for decades. However, the relationship between preclinical (second year or M2) OSCE grades and clerkship performance had never been evaluated, until it was explored to provide information to educators at the University of Nebraska Medical Center (UNMC). In addition, the relationship between M2 OSCE communication scores (which is a portion of the total score) and third-year (M3) Internal Medicine (IM) clerkship OSCE scores was also explored. Lastly, conflicting evidence exists about the relationship between the amount of previous clinical experience and OSCE performance. Therefore, the relationship between M3 IM clerkship OSCE scores and the timing of the clerkship in the academic year was explored. Data from UNMC M2 OSCEs and M3 IM clerkship OSCEs were obtained for graduates of the 2013 and 2014 classes. Specifically, the following data points were collected: M2 fall OSCE total, M2 fall OSCE communication; M2 spring OSCE total, M2 spring OSCE communication; and M3 IM clerkship OSCE total percentages. Data were organized by class, M3 IM clerkship OSCE performance, and timing of the clerkship. Microsoft Excel and SPSS were used for data organization and analysis. Of the 245 records, 229 (93.5%) had data points for all metrics of interest. Significant differences between the classes of 2013 and 2014 existed for average M2 spring total, M2 spring communication, and M3 IM clerkship OSCEs. Retrospectively, there were no differences in M2 OSCE performances based on how students scored on the M3 IM clerkship OSCE. M3 IM clerkship OSCE performance improved for those students who completed the clerkship last in the academic year. There were inconsistencies in OSCE performances between the classes of 2013 and 2014, but more information is needed to determine if this is because of testing variability or heterogeneity

  9. Spinal Cord Stimulation for Treating Chronic Pain: Reviewing Preclinical and Clinical Data on Paresthesia-Free High-Frequency Therapy.

    Science.gov (United States)

    Chakravarthy, Krishnan; Richter, Hira; Christo, Paul J; Williams, Kayode; Guan, Yun

    2018-01-01

    Traditional spinal cord stimulation (SCS) requires that paresthesia overlaps chronic painful areas. However, the new paradigm high-frequency SCS (HF-SCS) does not rely on paresthesia. A review of preclinical and clinical studies regarding the use of paresthesia-free HF-SCS for various chronic pain states. We reviewed available literatures on HF-SCS, including Nevro's paresthesia-free ultra high-frequency 10 kHz therapy (HF10-SCS). Data sources included relevant literature identified through searches of PubMed, MEDLINE/OVID, and SCOPUS, and manual searches of the bibliographies of known primary and review articles. The primary goal is to describe the present developing conceptions of preclinical mechanisms of HF-SCS and to review clinical efficacy on paresthesia-free HF10-SCS for various chronic pain states. HF10-SCS offers a novel pain reduction tool without paresthesia for failed back surgery syndrome and chronic axial back pain. Preclinical findings indicate that potential mechanisms of action for paresthesia-free HF-SCS differ from those of traditional SCS. To fully understand and utilize paresthesia-free HF-SCS, mechanistic study and translational research will be very important, with increasing collaboration between basic science and clinical communities to design better trials and optimize the therapy based on mechanistic findings from effective preclinical models and approaches. Future research in these vital areas may include preclinical and clinical components conducted in parallel to optimize the potential of this technology. © 2017 International Neuromodulation Society.

  10. Spontaneous Intracerebral Hemorrhage: Computed Tomographic Characteristics and Outcome

    Directory of Open Access Journals (Sweden)

    Aimara de la Caridad Vergara Santos

    2015-12-01

    Full Text Available Background: strokes are the third leading cause of death among adults and 10-15 % of them are due to spontaneous intracerebral hemorrhage. Objective: to characterize spontaneous intracerebral hemorrhage through computed tomography scan and its outcome. Methods: a case series study was conducted comprising patients diagnosed with spontaneous intracerebral hemorrhage admitted to the Arnaldo Milián Castro Provincial University Hospital in Villa Clara from January 2009 to January 2010. Tomographic variables of interest were derived from evaluation of spontaneous intracerebral hematomas. Results: fifty-nine cases of spontaneous intracerebral hemorrhage were studied, 23 were located in lobar regions, 4 had severe midline shift, and 2 showed volume greater than 80 ml. Eight out of eleven with extension into the ventricular system had an unfavorable outcome. Among those with thalamic hemorrhage, patients with diameter larger than 4cm and extension into the ventricular system died. Patients with putaminal hemorrhage larger than 4 cm and posterior fossa hematoma with hydrocephalus had a poor outcome, as well as most individuals (55 with other mass effects. Most lobar hematomas (14 out of 23 had a satisfactory outcome, unlike cerebellar and brainstem hematomas. Conclusions: tomographic variables that had a negative impact on the outcome were: volume greater than 80 ml, severe midline shift, diameter larger than 4 cm, extension into the ventricular system, hydrocephalus, other signs of mass effect and brainstem location.

  11. Clinical findings in 16 patients with tomographic diagnosis of schizencephaly

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Maria do Carmo de Souza [Universidade Federal do Espirito Santo, Vitoria, ES (Brazil). Hospital Universitario Cassiano Antonio Moraes]. E-mail: rodriguesmcs@yahoo.com.br; Monteiro, Alexandra Maria Vieira [Universidade do Estado do Rio de Janeiro, RJ (Brazil). Faculdade de Ciencias Medicas; Llerena Junior, Juan Clinton [Fundacao Oswaldo Cruz, Rio de Janeiro, RJ (Brazil). Instituto Fernandes Figueira. Centro de Genetica Medica; Fernandes, Alexandre Ribeiro [Universidade Gama Filho, Rio de Janeiro, RJ (Brazil). Dept. de Pediatria

    2006-09-15

    Objective: to establish a correlation between clinical features in a group of children with tomographic diagnosis of schizencephaly and clefts extent and localization. Materials and methods: retrospective study of dossiers from the archives of Neurology and Medical Genetics Services at Instituto Fernandes Figueira/FIOCRUZ and Hospital Municipal Jesus, Rio de Janeiro, RJ, Brazil, in the period between 2000 and 2003. The study included 16 patients, nine female and seven male, with tomographic diagnosis of schizencephaly investigated for clinical findings, psychomotor development, motor/cognitive deficits and epilepsy. Results: predominance of bilateral clefts in 10:16 patients, open-lip schizencephaly type in 23:27 patients, and small lips in 11:27 patients. As regards anomalies associated with schizencephaly, pellucid septum absence was the most frequent one (10:16 patients). As regards clinical findings, 15 patients presented with developmental delay and motor deficit, six patients with cognitive deficit and ten with epilepsy. In three patients, we observed discordant clinical findings and cleft sizes, although the clefts were small, the clinical features severity was high because of other cerebral anomalies. Conclusion: the clinical features of schizencephaly are related to the size of the clefts, regardless laterality, presenting higher severity when associated with other cerebral anomalies. (author)

  12. Tomographic reconstruction of OH* chemiluminescence in two interacting turbulent flames

    International Nuclear Information System (INIS)

    Worth, Nicholas A; Dawson, James R

    2013-01-01

    The tomographic reconstruction of OH* chemiluminescence was performed on two interacting turbulent premixed bluff-body stabilized flames under steady flow conditions and acoustic excitation. These measurements elucidate the complex three-dimensional (3D) vortex–flame interactions which have previously not been accessible. The experiment was performed using a single camera and intensifier, with multiple views acquired by repositioning the camera, permitting calculation of the mean and phase-averaged volumetric OH* distributions. The reconstructed flame structure and phase-averaged dynamics are compared with OH planar laser-induced fluorescence and flame surface density measurements for the first time. The volumetric data revealed that the large-scale vortex–flame structures formed along the shear layers of each flame collide when the two flames meet, resulting in complex 3D flame structures in between the two flames. With a fairly simple experimental setup, it is shown that the tomographic reconstruction of OH* chemiluminescence in forced flames is a powerful tool that can yield important physical insights into large-scale 3D flame dynamics that are important in combustion instability. (paper)

  13. Usefulness of tomographic phase image in ventricular conduction abnormalities

    International Nuclear Information System (INIS)

    Sakurai, Mitsuru; Watanabe, Yoshihiko; Kondo, Takeshi

    1985-01-01

    In order to evaluate three-dimensional phase changes in ventricular conduction abnormalities, tomographic phase images were constructed in 7 normal subjects, 12 patients with ventricular pacing, 21 patients with bundle branch block and 12 patients with Wolff-Parkinson-White syndrome. Eight to 12 slices of the short-axis ventricular tomographic phase image (TPI) were derived using a 7-pinhole collimator, and compared with planar phase images (PPIs) in left anterior oblique (LAO) and right anterior oblique (RAO) projections. TPIs were excellent for observing biventricular phase changes in the long-axis direction. In 6 cases of complete right bundle branch block with left axis deviation (beyond -30 0 ), the phase delay in the left ventricular anterior wall was recognized in 5 cases by TPI, although it was difficult to be detected by PPIs. The site of the pacing electrode was identified by TPI in 11 out of 12 cases, compared to 8 cases by PPIs in LAO and RAO projections. The site of the accessory pathway in Wolff-Parkinson-White syndrome was detected in the basal slice of TPIs in 10 out of 12 cases, compared to 8 cases by PPI in the LAO projection. Therefore, it is obvious that TPIs offer more valid information than PPIs. In conclusion, TPI is useful for investigation of ventricular conduction abnormalities. (author)

  14. Clinical findings in 16 patients with tomographic diagnosis of schizencephaly

    International Nuclear Information System (INIS)

    Rodrigues, Maria do Carmo de Souza; Monteiro, Alexandra Maria Vieira; Llerena Junior, Juan Clinton; Fernandes, Alexandre Ribeiro

    2006-01-01

    Objective: to establish a correlation between clinical features in a group of children with tomographic diagnosis of schizencephaly and clefts extent and localization. Materials and methods: retrospective study of dossiers from the archives of Neurology and Medical Genetics Services at Instituto Fernandes Figueira/FIOCRUZ and Hospital Municipal Jesus, Rio de Janeiro, RJ, Brazil, in the period between 2000 and 2003. The study included 16 patients, nine female and seven male, with tomographic diagnosis of schizencephaly investigated for clinical findings, psychomotor development, motor/cognitive deficits and epilepsy. Results: predominance of bilateral clefts in 10:16 patients, open-lip schizencephaly type in 23:27 patients, and small lips in 11:27 patients. As regards anomalies associated with schizencephaly, pellucid septum absence was the most frequent one (10:16 patients). As regards clinical findings, 15 patients presented with developmental delay and motor deficit, six patients with cognitive deficit and ten with epilepsy. In three patients, we observed discordant clinical findings and cleft sizes, although the clefts were small, the clinical features severity was high because of other cerebral anomalies. Conclusion: the clinical features of schizencephaly are related to the size of the clefts, regardless laterality, presenting higher severity when associated with other cerebral anomalies. (author)

  15. Initial results from the Donner 600 crystal positron tomograph

    International Nuclear Information System (INIS)

    Derenzo, S.E.; Huesman, R.H.; Cahoon, J.L.; Geyer, A.; Uber, D.; Vuletich, T.; Budinger, T.F.

    1986-10-01

    We describe a positron tomograph using a single ring of 600 close-packed 3 mm wide bismuth germanate (BGO) crystals coupled to 14 mm phototubes. The phototube preamplifier circuit derives a timing pulse from the first photoelectron, and sends it to address and coincidence circuits only if the integrated pulse height is within a pre-set window. The timing delays and pulse height windows for all 600 detectors and the coincidence timing windows are computer adjustable. An orbiting positron source is used for transmission measurements and a look-up table is used to reject scattered and random coincidences that do not pass through the source. Data can be acquired using a stationary mode for 1.57 mm lateral sampling or the two-position clam sampling mode for 0.79 mm lateral sampling. High maximum data rates are provided by 45 parallel coincidence circuits and 4 parallel histogram memory units. With two-position sampling and 1.57 mm bins, the reconstructed point spread function (PSF) of a 0.35 mm diam 22 Na wire source at the center of the tomograph is circular with 2.9 mm full-width at half-maximum (fwhm) and the PSF at a distance of 8 cm from the center is elliptical with a radial fwhm of 4.0 mm and tangential fwhm of 3.0 mm. 12 refs., 6 figs., 3 tabs

  16. Performance of analytical methods for tomographic gamma scanning

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Mercer, D.J.

    1997-01-01

    The use of gamma-ray computerized tomography for nondestructive assay of radioactive materials has led to the development of specialized analytical methods. Over the past few years, Los Alamos has developed and implemented a computer code, called ARC-TGS, for the analysis of data obtained by tomographic gamma scanning (TGS). ARC-TGS reduces TGS transmission and emission tomographic data, providing the user with images of the sample contents, the activity or mass of selected radionuclides, and an estimate of the uncertainty in the measured quantities. The results provided by ARC-TGS can be corrected for self-attenuation when the isotope of interest emits more than one gamma-ray. In addition, ARC-TGS provides information needed to estimate TGS quantification limits and to estimate the scan time needed to screen for small amounts of radioactivity. In this report, an overview of the analytical methods used by ARC-TGS is presented along with an assessment of the performance of these methods for TGS

  17. Tomographic Constraints on High-Energy Neutrinos of Hadronuclear Origin.

    Science.gov (United States)

    Ando, Shin'ichiro; Tamborra, Irene; Zandanel, Fabio

    2015-11-27

    Mounting evidence suggests that the TeV-PeV neutrino flux detected by the IceCube telescope has mainly an extragalactic origin. If such neutrinos are primarily produced by a single class of astrophysical sources via hadronuclear (pp) interactions, a similar flux of gamma-ray photons is expected. For the first time, we employ tomographic constraints to pinpoint the origin of the IceCube neutrino events by analyzing recent measurements of the cross correlation between the distribution of GeV gamma rays, detected by the Fermi satellite, and several galaxy catalogs in different redshift ranges. We find that the corresponding bounds on the neutrino luminosity density are up to 1 order of magnitude tighter than those obtained by using only the spectrum of the gamma-ray background, especially for sources with mild redshift evolution. In particular, our method excludes any hadronuclear source with a spectrum softer than E^{-2.1} as a main component of the neutrino background, if its evolution is slower than (1+z)^{3}. Starburst galaxies, if able to accelerate and confine cosmic rays efficiently, satisfy both spectral and tomographic constraints.

  18. Tomographic Environmental Sections for Environmental Mitigation Devices in Historical Centers

    Directory of Open Access Journals (Sweden)

    Roberta Cocci Grifoni

    2017-03-01

    Full Text Available Urban heat waves and the overall growing trend in the annual global temperature underline the importance of urban/architectural resilience and the need to reduce energy consumption. By designing urban voids, it is possible to create thermodynamic buffers, i.e., bubbles of controlled atmosphere that act as mediators between the natural and built environments, between the human body and the surrounding air, between meteorology and physiology (meteorological architecture. Multiple small actions in the urban fabric’s open spaces, such as replacing dark pavements or inserting vegetation and green spaces, are intended to improve outdoor comfort conditions and therefore the resilience of the city itself. This not only benefits the place’s quality, which is intrinsic to the new project, but also the insulating capacity of buildings, which are relieved of an external heat load. The design emphasis therefore changes from solid structures to the climate and weather conditions, which are invisible but perceivable. To design and control these constructed atmopheres, tomographic sections processed with computational fluid dynamics software (tomographic environmental section, TENS becomes necessary. It allows the effects of an extreme event on an outdoor environment to be evaluated in order to establish the appropriate (adaptive climate mitigation devices, especially in historical centers where energy retrofits are often discouraged. By fixing boundary conditions after a local intervention, the virtual environment can be simulated and then "sliced" to analyze initial values and verify the design improvements.

  19. DNA nanomaterials for preclinical imaging and drug delivery.

    Science.gov (United States)

    Jiang, Dawei; England, Christopher G; Cai, Weibo

    2016-10-10

    Besides being the carrier of genetic information, DNA is also an excellent biological organizer to establish well-designed nanostructures in the fields of material engineering, nanotechnology, and biomedicine. DNA-based materials represent a diverse nanoscale system primarily due to their predictable base pairing and highly regulated conformations, which greatly facilitate the construction of DNA nanostructures with distinct shapes and sizes. Integrating the emerging advancements in bioconjugation techniques, DNA nanostructures can be readily functionalized with high precision for many purposes ranging from biosensors to imaging to drug delivery. Recent progress in the field of DNA nanotechnology has exhibited collective efforts to employ DNA nanostructures as smart imaging agents or delivery platforms within living organisms. Despite significant improvements in the development of DNA nanostructures, there is limited knowledge regarding the in vivo biological fate of these intriguing nanomaterials. In this review, we summarize the current strategies for designing and purifying highly-versatile DNA nanostructures for biological applications, including molecular imaging and drug delivery. Since DNA nanostructures may elicit an immune response in vivo, we also present a short discussion of their potential toxicities in biomedical applications. Lastly, we discuss future perspectives and potential challenges that may limit the effective preclinical and clinical employment of DNA nanostructures. Due to their unique properties, we predict that DNA nanomaterials will make excellent agents for effective diagnostic imaging and drug delivery, improving patient outcome in cancer and other related diseases in the near future. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. The Study on Radioactive Nuclide Distributions within a Fuel Rod by Tomographic Gamma Scanning Method

    International Nuclear Information System (INIS)

    Quanhu, Zhang; Lee, H. K.; Hong, K. P.; Choo, Y. S.; Kim, D. S.

    2005-06-01

    Based on the specified need of the IMEF, the feasibility of Tomographic Gamma Scanning (TGS) technique has been investigated for its potential for non-destructive gamma scanning measurements of irradiated fuel rods. TGS technique has been developed for determining some radioactive isotopes' distributions of a fuel rod in hot cell. The results obtained from the simulation model extracting from real gamma scanning experimental condition in this work by new developed computer simulation codes confirmed that the gamma emission TGS technique has potential for determination of radioactive isotopes' distributions of a fuel rod. In order to verify the simulation codes, we have designed several computation schemes for both 3 by 3 and 10 by 10 fuel rod model under present situation at M1 hot cell in IMEF. The results which relative errors are less than 10% show that we have simulated and implemented determination of radioactive isotopes' distributions on simulated fuel rod by TGS technique successfully

  1. A fast tomographic method for searching the minimum free energy path

    International Nuclear Information System (INIS)

    Chen, Changjun; Huang, Yanzhao; Xiao, Yi; Jiang, Xuewei

    2014-01-01

    Minimum Free Energy Path (MFEP) provides a lot of important information about the chemical reactions, like the free energy barrier, the location of the transition state, and the relative stability between reactant and product. With MFEP, one can study the mechanisms of the reaction in an efficient way. Due to a large number of degrees of freedom, searching the MFEP is a very time-consuming process. Here, we present a fast tomographic method to perform the search. Our approach first calculates the free energy surfaces in a sequence of hyperplanes perpendicular to a transition path. Based on an objective function and the free energy gradient, the transition path is optimized in the collective variable space iteratively. Applications of the present method to model systems show that our method is practical. It can be an alternative approach for finding the state-to-state MFEP

  2. TomoEED: Fast Edge-Enhancing Denoising of Tomographic Volumes.

    Science.gov (United States)

    Moreno, J J; Martínez-Sánchez, A; Martínez, J A; Garzón, E M; Fernández, J J

    2018-05-29

    TomoEED is an optimized software tool for fast feature-preserving noise filtering of large 3D tomographic volumes on CPUs and GPUs. The tool is based on the anisotropic nonlinear diffusion method. It has been developed with special emphasis in the reduction of the computational demands by using different strategies, from the algorithmic to the high performance computing perspectives. TomoEED manages to filter large volumes in a matter of minutes in standard computers. TomoEED has been developed in C. It is available for Linux platforms at http://www.cnb.csic.es/%7ejjfernandez/tomoeed. gmartin@ual.es, JJ.Fernandez@csic.es. Supplementary data are available at Bioinformatics online.

  3. SXR measurement and W transport survey using GEM tomographic system on WEST

    Science.gov (United States)

    Mazon, D.; Jardin, A.; Malard, P.; Chernyshova, M.; Coston, C.; Malard, P.; O'Mullane, M.; Czarski, T.; Malinowski, K.; Faisse, F.; Ferlay, F.; Verger, J. M.; Bec, A.; Larroque, S.; Kasprowicz, G.; Wojenski, A.; Pozniak, K.

    2017-11-01

    Measuring Soft X-Ray (SXR) radiation (0.1-20 keV) of fusion plasmas is a standard way of accessing valuable information on particle transport. Since heavy impurities like tungsten (W) could degrade plasma core performances and cause radiative collapses, it is necessary to develop new diagnostics to be able to monitor the impurity distribution in harsh fusion environments like ITER. A gaseous detector with energy discrimination would be a very good candidate for this purpose. The design and implementation of a new SXR diagnostic developed for the WEST project, based on a triple Gas Electron Multiplier (GEM) detector is presented. This detector works in photon counting mode and presents energy discrimination capabilities. The SXR system is composed of two 1D cameras (vertical and horizontal views respectively), located in the same poloidal cross-section to allow for tomographic reconstruction. An array (20 cm × 2 cm) consists of up to 128 detectors in front of a beryllium pinhole (equipped with a 1 mm diameter diaphragm) inserted at about 50 cm depth inside a cooled thimble in order to retrieve a wide plasma view. Acquisition of low energy spectrum is insured by a helium buffer installed between the pinhole and the detector. Complementary cooling systems (water) are used to maintain a constant temperature (25oC) inside the thimble. Finally a real-time automatic extraction system has been developed to protect the diagnostic during baking phases or any overheating unwanted events. Preliminary simulations of plasma emissivity and W distribution have been performed for WEST using a recently developed synthetic diagnostic coupled to a tomographic algorithm based on the minimum Fisher information (MFI) inversion method. First GEM acquisitions are presented as well as estimation of transport effect in presence of ICRH on W density reconstruction capabilities of the GEM.

  4. Application of tomographic inversion in studying airglow in the mesopause region

    Directory of Open Access Journals (Sweden)

    T. Nygrén

    Full Text Available It is pointed out that observations of periodic nightglow structures give excellent information on atmospheric gravity waves in the mesosphere and lower thermosphere. The periods, the horizontal wavelengths and the phase speeds of the waves can be determined from airglow images and, using several cameras, the approximate altitude of the luminous layer can also be determined by triangulation. In this paper the possibility of applying tomographic methods for reconstructing the airglow structures is investigated using numerical simulations. A ground-based chain of cameras is assumed, two-dimensional airglow models in the vertical plane above the chain are constructed, and simulated data are calculated by integrating the models along a great number of rays with different elevation angles for each camera. After addition of random noise, these data are then inverted to obtain reconstructions of the models. A tomographic analysis package originally designed for satellite radiotomography is used in the inversion. The package is based on a formulation of stochastic inversion which allows the input of a priori information to the solver in terms of regularization variances. The reconstruction is carried out in two stages. In the first inversion, constant regularization variances are used within a wide altitude range. The results are used in determining the approximate altitude range of the airglow structures. Then, in the second inversion, constant non-zero regularization variances are used inside this region and zero variances outside it. With this method reliable reconstructions of the models are obtained. The number of cameras as well as their separations are varied in order to find out the limitations of the method.

    Key words. Tomography · Airglow · Mesopause · Gravity waves

  5. Pre-clinical research in small animals using radiotherapy technology. A bidirectional translational approach

    International Nuclear Information System (INIS)

    Tillner, Falk; Buetof, Rebecca; Krause, Mechthild; Enghardt, Wolfgang; Helmholtz-Zentrum Dresden-Rossendorf, Dresden; Technische Univ. Dresden; Helmholtz-Zentrum Dresden-Rossendorf, Dresden

    2014-01-01

    For translational cancer research, pre-clinical in-vivo studies using small animals have become indispensable in bridging the gap between in-vitro cell experiments and clinical implementation. When setting up such small animal experiments, various biological, technical and methodical aspects have to be considered. In this work we present a comprehensive topical review based on relevant publications on irradiation techniques used for pre-clinical cancer research in mice and rats. Clinical radiotherapy treatment devices for the application of external beam radiotherapy and brachytherapy as well as dedicated research irradiation devices are feasible for small animal irradiation depending on the animal model and the experimental goals. In this work, appropriate solutions for the technological transfer of human radiation oncology to small animal radiation research are summarised. Additionally, important information concerning the experimental design is provided such that reliable and clinically relevant results can be attained.

  6. Tendinopathies and platelet-rich plasma (PRP: from pre-clinical experiments to therapeutic use

    Directory of Open Access Journals (Sweden)

    Kaux JF

    2015-05-01

    Full Text Available Objectives: The restorative properties of platelets, through the local release of growth factors, are used in various medical areas. This article reviews fundamental and clinical research relating to platelet-rich plasma applied to tendinous lesions. Materials and method: Articles in French and English, published between 1 January 2012 and 31 December 2014. dealing with PRP and tendons were searched for using the Medline and Scopus data bases. Results: Forty-seven articles were identified which addressed pre-clinical and clinical studies: 27 relating to in vitro and in vivo animal studies and 20 relating to human studies. Of these, five addressed lateral epicondylitis, two addressed rotator cuff tendinopathies, ten dealt with patellar tendinopathies and three looked at Achilles tendinopathies. Conclusions: The majority of pre-clinical studies show that PRP stimulates the tendon's healing process. However, clinical series remain more controversial and level 1, controlled, randomised studies are still needed.

  7. Pre-clinical research in small animals using radiotherapy technology--a bidirectional translational approach.

    Science.gov (United States)

    Tillner, Falk; Thute, Prasad; Bütof, Rebecca; Krause, Mechthild; Enghardt, Wolfgang

    2014-12-01

    For translational cancer research, pre-clinical in-vivo studies using small animals have become indispensable in bridging the gap between in-vitro cell experiments and clinical implementation. When setting up such small animal experiments, various biological, technical and methodical aspects have to be considered. In this work we present a comprehensive topical review based on relevant publications on irradiation techniques used for pre-clinical cancer research in mice and rats. Clinical radiotherapy treatment devices for the application of external beam radiotherapy and brachytherapy as well as dedicated research irradiation devices are feasible for small animal irradiation depending on the animal model and the experimental goals. In this work, appropriate solutions for the technological transfer of human radiation oncology to small animal radiation research are summarised. Additionally, important information concerning the experimental design is provided such that reliable and clinically relevant results can be attained. Copyright © 2014. Published by Elsevier GmbH.

  8. Pre-clinical research in small animals using radiotherapy technology. A bidirectional translational approach

    Energy Technology Data Exchange (ETDEWEB)

    Tillner, Falk; Buetof, Rebecca [Technische Univ. Dresden (Germany). OncoRay - National Center for Radiation Research in Oncology; Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Technische Univ. Dresden (Germany). Dept. of Radiation Oncology; Thute, Prasad [Technische Univ. Dresden (Germany). OncoRay - National Center for Radiation Research in Oncology; Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Krause, Mechthild [Technische Univ. Dresden (Germany). OncoRay - National Center for Radiation Research in Oncology; Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Technische Univ. Dresden (Germany). Dept. of Radiation Oncology; German Cancer Consortium (DKTK), Dresden (Germany); German Cancer Research Center (DKFZ), Heidelberg (Germany); Enghardt, Wolfgang [Technische Univ. Dresden (Germany). OncoRay - National Center for Radiation Research in Oncology; Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Technische Univ. Dresden (Germany). Dept. of Radiation Oncology; Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany). Inst. of Radiooncology

    2014-07-01

    For translational cancer research, pre-clinical in-vivo studies using small animals have become indispensable in bridging the gap between in-vitro cell experiments and clinical implementation. When setting up such small animal experiments, various biological, technical and methodical aspects have to be considered. In this work we present a comprehensive topical review based on relevant publications on irradiation techniques used for pre-clinical cancer research in mice and rats. Clinical radiotherapy treatment devices for the application of external beam radiotherapy and brachytherapy as well as dedicated research irradiation devices are feasible for small animal irradiation depending on the animal model and the experimental goals. In this work, appropriate solutions for the technological transfer of human radiation oncology to small animal radiation research are summarised. Additionally, important information concerning the experimental design is provided such that reliable and clinically relevant results can be attained.

  9. Preclinical imaging characteristics and quantification of Platinum-195m SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Aalbersberg, E.A.; Wit-van der Veen, B.J. de; Vegt, E.; Vogel, Wouter V. [The Netherlands Cancer Institute (NKI-AVL), Department of Nuclear Medicine, Amsterdam (Netherlands); Zwaagstra, O.; Codee-van der Schilden, K. [Nuclear Research and Consultancy Group (NRG), Petten (Netherlands)

    2017-08-15

    In vivo biodistribution imaging of platinum-based compounds may allow better patient selection for treatment with chemo(radio)therapy. Radiolabeling with Platinum-195m ({sup 195m}Pt) allows SPECT imaging, without altering the chemical structure or biological activity of the compound. We have assessed the feasibility of {sup 195m}Pt SPECT imaging in mice, with the aim to determine the image quality and accuracy of quantification for current preclinical imaging equipment. Enriched (>96%) {sup 194}Pt was irradiated in the High Flux Reactor (HFR) in Petten, The Netherlands (NRG). A 0.05 M HCl {sup 195m}Pt-solution with a specific activity of 33 MBq/mg was obtained. Image quality was assessed for the NanoSPECT/CT (Bioscan Inc., Washington DC, USA) and U-SPECT{sup +}/CT (MILabs BV, Utrecht, the Netherlands) scanners. A radioactivity-filled rod phantom (rod diameter 0.85-1.7 mm) filled with 1 MBq {sup 195m}Pt was scanned with different acquisition durations (10-120 min). Four healthy mice were injected intravenously with 3-4 MBq {sup 195m}Pt. Mouse images were acquired with the NanoSPECT for 120 min at 0, 2, 4, or 24 h after injection. Organs were delineated to quantify {sup 195m}Pt concentrations. Immediately after scanning, the mice were sacrificed, and the platinum concentration was determined in organs using a gamma counter and graphite furnace - atomic absorption spectroscopy (GF-AAS) as reference standards. A 30-min acquisition of the phantom provided visually adequate image quality for both scanners. The smallest visible rods were 0.95 mm in diameter on the NanoSPECT and 0.85 mm in diameter on the U-SPECT{sup +}. The image quality in mice was visually adequate. Uptake was seen in the kidneys with excretion to the bladder, and in the liver, blood, and intestine. No uptake was seen in the brain. The Spearman correlation between SPECT and gamma counter was 0.92, between SPECT and GF-AAS it was 0.84, and between GF-AAS and gamma counter it was0.97 (all p < 0

  10. Impact of attenuation correction strategies on the quantification of High Resolution Research Tomograph PET studies

    International Nuclear Information System (INIS)

    Velden, Floris H P van; Kloet, Reina W; Berckel, Bart N M van; Molthoff, Carla F M; Jong, Hugo W A M de; Lammertsma, Adriaan A; Boellaard, Ronald

    2008-01-01

    In this study, the quantitative accuracy of different attenuation correction strategies presently available for the High Resolution Research Tomograph (HRRT) was investigated. These attenuation correction methods differ in reconstruction and processing (segmentation) algorithms used for generating a μ-image from measured 2D transmission scans, an intermediate step in the generation of 3D attenuation correction factors. Available methods are maximum-a-posteriori reconstruction (MAP-TR), unweighted OSEM (UW-OSEM) and NEC-TR, which transforms sinogram values back to their noise equivalent counts (NEC) to restore Poisson distribution. All methods can be applied with or without μ-image segmentation. However, for MAP-TR a μ-histogram is a prior during reconstruction. All possible strategies were evaluated using phantoms of various sizes, simulating preclinical and clinical situations. Furthermore, effects of emission contamination of the transmission scan on the accuracy of various attenuation correction strategies were studied. Finally, the accuracy of various attenuation corrections strategies and its relative impact on the reconstructed activity concentration (AC) were evaluated using small animal and human brain studies. For small structures, MAP-TR with human brain priors showed smaller differences in μ-values for transmission scans with and without emission contamination (<8%) than the other methods (<26%). In addition, it showed best agreement with true AC (deviation <4.5%). A specific prior designed to take into account the presence of small animal fixation devices only very slightly improved AC precision to 4.3%. All methods scaled μ-values of a large homogeneous phantom to within 4% of the water peak, but MAP-TR provided most accurate AC after reconstruction. However, for clinical data MAP-TR using the default prior settings overestimated the thickness of the skull, resulting in overestimations of μ-values in regions near the skull and thus in incorrect

  11. Preclinical Medical Student Hematology/Oncology Education Environment.

    Science.gov (United States)

    Zumberg, Marc S; Broudy, Virginia C; Bengtson, Elizabeth M; Gitlin, Scott D

    2015-12-01

    To better prepare medical students to care for patients in today's changing health-care environment as they transition to continuing their education as residents, many US medical schools have been reviewing and modifying their curricula and are considering integration of newer adult learning techniques, including team-based learning, flipped classrooms, and other active learning approaches (Assoc Am Med Coll. 2014). Directors of hematology/oncology (H/O) courses requested an assessment of today's H/O education environment to help them respond to the ongoing changes in the education content and environment that will be necessary to meet this goal. Several recommendations for the improvement of cancer education resulted from American Association for Cancer Education's (ACCE's) "Cancer Education Survey II" including a call for medical schools to evaluate the effectiveness of current teaching methods in achieving cancer education objectives (Chamberlain et al. J Cancer Educ 7(2):105-114.2014). To understand the current environment and resources used in medical student preclinical H/O courses, an Internet-based, Survey Monkey®-formatted, questionnaire focusing on nine topic areas was distributed to 130 United States Hematology/Oncology Course Directors (HOCDs). HOCDs represent a diverse group of individuals who work in variably supportive environments and who are variably satisfied with their position. Several aspects of these courses remain relatively unchanged from previous assessments, including a predominance of traditional lectures, small group sessions, and examinations that are either written or computer-based. Newer technology, including web-based reproduction of lectures, virtual microscopes, and availability of additional web-based content has been introduced into these courses. A variety of learner evaluation and course assessment approaches are used. The ultimate effectiveness and impact of these changes needs to be determined.

  12. Early bedside care during preclinical medical education: can technology-enhanced patient simulation advance the Flexnerian ideal?

    Science.gov (United States)

    Gordon, James A; Hayden, Emily M; Ahmed, Rami A; Pawlowski, John B; Khoury, Kimberly N; Oriol, Nancy E

    2010-02-01

    Flexner wanted medical students to study at the patient bedside-a remarkable innovation in his time-so that they could apply science to clinical care under the watchful eye of senior physicians. Ever since his report, medical schools have reserved the latter years of their curricula for such an "advanced" apprenticeship, providing clinical clerkship experiences only after an initial period of instruction in basic medical sciences. Although Flexner codified the segregation of preclinical and clinical instruction, he was committed to ensuring that both domains were integrated into a modern medical education. The aspiration to fully integrate preclinical and clinical instruction continues to drive medical education reform even to this day. In this article, the authors revisit the original justification for sequential preclinical-clinical instruction and argue that modern, technology-enhanced patient simulation platforms are uniquely powerful for fostering simultaneous integration of preclinical-clinical content in a way that Flexner would have applauded. To date, medical educators tend to focus on using technology-enhanced medical simulation in clinical and postgraduate medical education; few have devoted significant attention to using immersive clinical simulation among preclinical students. The authors present an argument for the use of dynamic robot-mannequins in teaching basic medical science, and describe their experience with simulator-based preclinical instruction at Harvard Medical School. They discuss common misconceptions and barriers to the approach, describe their curricular responses to the technique, and articulate a unifying theory of cognitive and emotional learning that broadens the view of what is possible, feasible, and desirable with simulator-based medical education.

  13. Guidance for Methods Descriptions Used in Preclinical Imaging Papers

    Directory of Open Access Journals (Sweden)

    David Stout

    2013-10-01

    Full Text Available Preclinical molecular imaging is a rapidly growing field, where new imaging systems, methods, and biological findings are constantly being developed or discovered. Imaging systems and the associated software usually have multiple options for generating data, which is often overlooked but is essential when reporting the methods used to create and analyze data. Similarly, the ways in which animals are housed, handled, and treated to create physiologically based data must be well described in order that the findings be relevant, useful, and reproducible. There are frequently new developments for metabolic imaging methods. Thus, specific reporting requirements are difficult to establish; however, it remains essential to adequately report how the data have been collected, processed, and analyzed. To assist with future manuscript submissions, this article aims to provide guidelines of what details to report for several of the most common imaging modalities. Examples are provided in an attempt to give comprehensive, succinct descriptions of the essential items to report about the experimental process.

  14. Preclinical and Clinical Effects of Mistletoe against Breast Cancer

    Directory of Open Access Journals (Sweden)

    Mohsen Marvibaigi

    2014-01-01

    Full Text Available Breast cancer is among the most frequent types of cancer in women worldwide. Current conventional treatment options are accompanied by side effects. Mistletoe is amongst the important herbal medicines traditionally used as complementary remedies. An increasing number of studies have reported anticancer activity of mistletoe extracts on breast cancer cells and animal models. Some recent evidence suggests that cytotoxic activity of mistletoe may be mediated through different mechanisms. These findings provide a good base for clinical trials. Various studies on mistletoe therapy for breast cancer patients revealed similar findings concerning possible benefits on survival time, health-related quality of life (HRQoL, remission rate, and alleviating adverse reactions to conventional therapy. This review provides an overview of the recent findings on preclinical experiments and clinical trials of mistletoe for its cytotoxic and antitumor activity and its effect on HRQoL in breast cancer patients. Moreover, studies investigating molecular and cellular mechanisms underlying antitumor activity of mistletoe are discussed in this paper. The analyzed trials provided evidence that there might be a combination of pharmacological and motivational aspects mediated by the mistletoe extract application which may contribute to the clinical benefit and positive outcome such as improved HRQoL and self-regulation in breast cancer patients.

  15. Preclinical evaluation of molecular-targeted anticancer agents for radiotherapy

    International Nuclear Information System (INIS)

    Krause, Mechthild; Zips, Daniel; Thames, Howard D.; Kummermehr, Johann; Baumann, Michael

    2006-01-01

    The combination of molecular-targeted agents with irradiation is a highly promising avenue for cancer research and patient care. Molecular-targeted agents are in themselves not curative in solid tumours, whereas radiotherapy is highly efficient in eradicating tumour stem cells. Recurrences after high-dose radiotherapy are caused by only one or few surviving tumour stem cells. Thus, even if a novel agent has the potential to kill only few tumour stem cells, or if it interferes in mechanisms of radioresistance of tumours, combination with radiotherapy may lead to an important improvement in local tumour control and survival. To evaluate the effects of novel agents combined with radiotherapy, it is therefore necessary to use experimental endpoints which reflect the killing of tumour stem cells, in particular tumour control assays. Such endpoints often do not correlate with volume-based parameters of tumour response such as tumour regression and growth delay. This calls for radiotherapy specific research strategies in the preclinical testing of novel anti-cancer drugs, which in many aspects are different from research approaches for medical oncology

  16. Hybrid Photoacoustic/Ultrasound Tomograph for Real-Time Finger Imaging.

    Science.gov (United States)

    Oeri, Milan; Bost, Wolfgang; Sénégond, Nicolas; Tretbar, Steffen; Fournelle, Marc

    2017-10-01

    We report a target-enclosing, hybrid tomograph with a total of 768 elements based on capacitive micromachined ultrasound transducer technology and providing fast, high-resolution 2-D/3-D photoacoustic and ultrasound tomography tailored to finger imaging. A freely programmable ultrasound beamforming platform sampling data at 80 MHz was developed to realize plane wave transmission under multiple angles. A multiplexing unit enables the connection and control of a large number of elements. Fast image reconstruction is provided by GPU processing. The tomograph is composed of four independent and fully automated movable arc-shaped transducers, allowing imaging of all three finger joints. The system benefits from photoacoustics, yielding high optical contrast and enabling visualization of finger vascularization, and ultrasound provides morphologic information on joints and surrounding tissue. A diode-pumped, Q-switched Nd:YAG laser and an optical parametric oscillator are used to broaden the spectrum of emitted wavelengths to provide multispectral imaging. Custom-made optical fiber bundles enable illumination of the region of interest in the plane of acoustic detection. Precision in positioning of the probe in motion is ensured by use of a motor-driven guide slide. The current position of the probe is encoded by the stage and used to relate ultrasound and photoacoustic signals to the corresponding region of interest of the suspicious finger joint. The system is characterized in phantoms and a healthy human finger in vivo. The results obtained promise to provide new opportunities in finger diagnostics and establish photoacoustic/ultrasound-tomography in medical routine. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  17. On the estimation of wall pressure coherence using time-resolved tomographic PIV

    Science.gov (United States)

    Pröbsting, Stefan; Scarano, Fulvio; Bernardini, Matteo; Pirozzoli, Sergio

    2013-07-01

    Three-dimensional time-resolved velocity field measurements are obtained using a high-speed tomographic Particle Image Velocimetry (PIV) system on a fully developed flat plate turbulent boundary layer for the estimation of wall pressure fluctuations. The work focuses on the applicability of tomographic PIV to compute the coherence of pressure fluctuations, with attention to the estimation of the stream and spanwise coherence length. The latter is required for estimations of aeroacoustic noise radiation by boundary layers and trailing edge flows, but is also of interest for vibro-structural problems. The pressure field is obtained by solving the Poisson equation for incompressible flows, where the source terms are provided by time-resolved velocity field measurements. Measured 3D velocity data is compared to results obtained from planar PIV, and a Direct Numerical Simulation (DNS) at similar Reynolds number. An improved method for the estimation of the material based on a least squares estimator of the velocity derivative along a particle trajectory is proposed and applied. Computed surface pressure fluctuations are further verified by means of simultaneous measurements by a pinhole microphone and compared to the DNS results and a semi-empirical model available from literature. The correlation coefficient for the reconstructed pressure time series with respect to pinhole microphone measurements attains approximately 0.5 for the band-pass filtered signal over the range of frequencies resolved by the velocity field measurements. Scaled power spectra of the pressure at a single point compare favorably to the DNS results and those available from literature. Finally, the coherence of surface pressure fluctuations and the resulting span- and streamwise coherence lengths are estimated and compared to semi-empirical models and DNS results.

  18. Determination of spatial resolution of positron emission tomograph of clear PET-XPAD3/CT system

    Energy Technology Data Exchange (ETDEWEB)

    Olaya D, H.; Martinez O, S. A. [Universidad Pedagogica y Tecnologica de Colombia, Grupo de Fisica Nuclear Aplicada y Simulacion, 150003 Tunja, Boyaca (Colombia); Morel, C. [Centre de Physique des Particules de Marseille, ImXgam Group, 13009 Marseille (France); Castro, H. F. [Universidad Nacional de Colombia, Physics Department, Carrera 45 No. 26-85, Bogota (Colombia)

    2016-10-15

    Based on the National Electrical Manufacturers Association (Nema), using the Amine software to construction of sinograms and using a radioactive source {sup 22}Na that emitting positrons were made calculations for determine spatial resolution of ring array system of phoswich detectors of positron emission tomograph included in the Clear PET-XPAD3/CT prototype for small animals made in the laboratories of CCPM and whose project is led by the research group ImXgam. The radioactive source {sup 22}Na approximately 9 MBq of activity, with spherical shape and diameter of 0.57 mm immersed in a plexiglas disc was located at the geometric center of tomographic system with a Field of View (Fov) of 35 mm in the axial and transverse directions. Displacements of radioactive source were performed on the three cartesian axes and was rebuilt a sinogram for each axis. The shape of sinogram allow describe the correct position and the maximum efficiency of each detector. Subsequently, was carried out a scanning in each one of three spatial axes taking an enough distance covering the dimensions of radioactive source, were recorded data for each one of phoswich detector crystals which are aligned in the axis of movement. The process was repeated for other axes and then was offsetting the radioactive source with respect to the Fov and were calculated FWHM (Full Width at Half Maximum) and FWTM (Full Width at Tenth Maximum) values and performing statistics of these values with parabolic fitting, the latter setting allows to obtain parameters of spatial resolution of system. (Author)

  19. Determination of spatial resolution of positron emission tomograph of clear PET-XPAD3/CT system

    International Nuclear Information System (INIS)

    Olaya D, H.; Martinez O, S. A.; Morel, C.; Castro, H. F.

    2016-10-01

    Based on the National Electrical Manufacturers Association (Nema), using the Amine software to construction of sinograms and using a radioactive source "2"2Na that emitting positrons were made calculations for determine spatial resolution of ring array system of phoswich detectors of positron emission tomograph included in the Clear PET-XPAD3/CT prototype for small animals made in the laboratories of CCPM and whose project is led by the research group ImXgam. The radioactive source "2"2Na approximately 9 MBq of activity, with spherical shape and diameter of 0.57 mm immersed in a plexiglas disc was located at the geometric center of tomographic system with a Field of View (Fov) of 35 mm in the axial and transverse directions. Displacements of radioactive source were performed on the three cartesian axes and was rebuilt a sinogram for each axis. The shape of sinogram allow describe the correct position and the maximum efficiency of each detector. Subsequently, was carried out a scanning in each one of three spatial axes taking an enough distance covering the dimensions of radioactive source, were recorded data for each one of phoswich detector crystals which are aligned in the axis of movement. The process was repeated for other axes and then was offsetting the radioactive source with respect to the Fov and were calculated FWHM (Full Width at Half Maximum) and FWTM (Full Width at Tenth Maximum) values and performing statistics of these values with parabolic fitting, the latter setting allows to obtain parameters of spatial resolution of system. (Author)

  20. Ghost hunting—an assessment of ghost particle detection and removal methods for tomographic-PIV

    International Nuclear Information System (INIS)

    Elsinga, G E; Tokgoz, S

    2014-01-01

    This paper discusses and compares several methods, which aim to remove spurious peaks, i.e. ghost particles, from the volume intensity reconstruction in tomographic-PIV. The assessment is based on numerical simulations of time-resolved tomographic-PIV experiments in linear shear flows. Within the reconstructed volumes, intensity peaks are detected and tracked over time. These peaks are associated with particles (either ghosts or actual particles) and are characterized by their peak intensity, size and track length. Peak intensity and track length are found to be effective in discriminating between most ghosts and the actual particles, although not all ghosts can be detected using only a single threshold. The size of the reconstructed particles does not reveal an important difference between ghosts and actual particles. The joint distribution of peak intensity and track length however does, under certain conditions, allow a complete separation of ghosts and actual particles. The ghosts can have either a high intensity or a long track length, but not both combined, like all the actual particles. Removing the detected ghosts from the reconstructed volume and performing additional MART iterations can decrease the particle position error at low to moderate seeding densities, but increases the position error, velocity error and tracking errors at higher densities. The observed trends in the joint distribution of peak intensity and track length are confirmed by results from a real experiment in laminar Taylor–Couette flow. This diagnostic plot allows an estimate of the number of ghosts that are indistinguishable from the actual particles. (paper)

  1. Challenges for Preclinical Investigations of Human Biofield Modalities

    Science.gov (United States)

    Gronowicz, Gloria; Bengston, William

    2015-01-01

    Preclinical models for studying the effects of the human biofield have great potential to advance our understanding of human biofield modalities, which include external qigong, Johrei, Reiki, therapeutic touch, healing touch, polarity therapy, pranic healing, and other practices. A short history of Western biofield studies using preclinical models is presented and demonstrates numerous and consistent examples of human biofields significantly affecting biological systems both in vitro and in vivo. Methodological issues arising from these studies and practical solutions in experimental design are presented. Important questions still left unanswered with preclinical models include variable reproducibility, dosing, intentionality of the practitioner, best preclinical systems, and mechanisms. Input from the biofield practitioners in the experimental design is critical to improving experimental outcomes; however, the development of standard criteria for uniformity of practice and for inclusion of multiple practitioners is needed. Research in human biofield studies involving preclinical models promises a better understanding of the mechanisms underlying the efficacy of biofield therapies and will be important in guiding clinical protocols and integrating treatments with conventional medical therapies. PMID:26665042

  2. The development of a compact positron tomograph for prostate imaging

    Energy Technology Data Exchange (ETDEWEB)

    Huber, Jennifer S.; Qi, Jinyi; Derenzo, Stephen E.; Moses, William W.; Huesman, Ronald H.; Budinger, Thomas F.

    2002-12-17

    We give design details and expected image results of a compact positron tomograph designed for prostate imaging that centers a patient between a pair of external curved detector banks (ellipse: 45 cm minor, 70 cm major axis). The bottom bank is fixed below the patient bed, and the top bank moves upward for patient access and downward for maximum sensitivity. Each bank is composed of two rows (axially) of 20 CTI PET Systems HR+ block detectors, forming two arcs that can be tilted to minimize attenuation. Compared to a conventional PET system, our camera uses about one-quarter the number of detectors and has almost two times higher solid angle coverage for a central point source, because the detectors are close to the patient. The detectors are read out by modified CTI HRRT data acquisition electronics. The individual detectors are angled in the plane to point towards the prostate to minimize reso

  3. Clinical significance of computed tomographic arteriography for minute hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, H; Matsui, O; Suzuki, M; Ida, M; Kitagawa, K [Kanazawa Univ. (Japan). School of Medicine

    1982-03-01

    Computed tomographic arteriography (CTA) can clearly demonstrate minute hepatocellular carcinoma (H.C.C.) more than 2 cm in diameter as an enhanced mass lesion. In this case the precise localization of H.C.C. becomes so obvious that CTA plays an important role to evaluate its resectability. However, H.C.C. of the size from 2 cm to 1 cm indiameter, which is visualized with celiac and infusion hepatic angiography, becomes more difficult in detection, and particularly H.C.C. of less than 1 cm in diameter can hardly be recognized, nor be diagnosed as a malignant nodule by CTA, therefore it appears that in these sizes of H.C.C. the detectability of CTA is not superior to the hepatic angiography.

  4. Computer tomographic and angiographic studies of histologically confirmed intrahepatic masses

    International Nuclear Information System (INIS)

    Janson, R.; Lackner, K.; Paquet, K.J.; Thelen, M.; Thurn, P.

    1980-01-01

    The computer tomographic and angiographic findings in 53 patients with intrahepatic masses were compared. The histological findings show that 17 were due to echinococcus, 12 were due to hepatic carcinoma, ten were metastases, five patients had focal nodular hyperplasia, three an alveolar echinococcus and there were three cases with an haemangioma of the liver and a further three liver abscesses. Computer tomography proved superior in peripherally situated lesions, and in those in the left lobe of the liver. Arteriography was better at demonstrating lesions below 2 cm in size, particularly vascular tumours. As a pre-operative measure, angiography is to be preferred since it is able to demonstrate anatomic anomalies and variations in the blood supply, as well as invasion of the portal vein or of the inferior vena cava. (orig.) [de

  5. Computer tomographic and angiographic studies of histologically confirmed intrahepatic masses

    Energy Technology Data Exchange (ETDEWEB)

    Janson, R.; Lackner, K.; Paquet, K.J.; Thelen, M.; Thurn, P.

    1980-06-01

    The computer tomographic and angiographic findings in 53 patients with intrahepatic masses were compared. The histological findings show that 17 were due to echinococcus, 12 were due to hepatic carcinoma, ten were metastases, five patients had focal nodular hyperplasia, three an alveolar echinococcus and there were three cases with an haemangioma of the liver and a further three liver abscesses. Computer tomography proved superior in peripherally situated lesions, and in those in the left lobe of the liver. Arteriography was better at demonstrating lesions below 2 cm in size, particularly vascular tumours. As a pre-operative measure, angiography is to be preferred since it is able to demonstrate anatomic anomalies and variations in the blood supply, as well as invasion of the portal vein or of the inferior vena cava.

  6. Computed tomographic study of hormone-secreting microadenomas

    International Nuclear Information System (INIS)

    Hemminghytt, S.; Kalkhoff, R.K.; Daniels, D.L.; Williams, A.L.; Grogan, J.P.; Haughton, V.M.

    1983-01-01

    A review was made of the computed tomographic (CT) studies of 33 patients with hormone-secreting microadenomas that had been verified by transsphenoidal surgery and endocrinologic evaluation. In previous studies in small series of patients, the CT appearance of pituitary microadenomas has been reported as hypodense, isodense, and hyperdense. In this study, CT showed a region of diminished enhancement and ususally an enlarged pituitary gland in cases of prolactin-secreting adenomas. HGH- or ACTH-secreting adenomas were less consistently hypodense. It is concluded that hypodensity and enlargement in the pituitary gland are the most useful criteria for identification of microadenomas. Some technical factors that may affect the CT appearance of microadenomas and lead to conflicting reports are discussed

  7. Central nervous system leukemia and lymphoma: computed tomographic manifestations

    International Nuclear Information System (INIS)

    Pagani, J.J.; Libshitz, H.I.; Wallace, S.; Hayman, L.A.

    1981-01-01

    Computed tomographic (CT) abnormalities in the brain were identified in 31 of 405 patients with leukemia or lymphoma. Abnormalities included neoplastic masses (15), hemorrhage (nine), abscess (two), other brain tumors (four), and methotrexate leukoencephalopathy (one). CT was normal in 374 patients including 148 with meningeal disease diagnosed by cerebrospinal fluid cytologic examination. Prior to treatment, malignant masses were isodense or of greater density with varying amounts of edema. Increase in size or number of the masses indicated worsening. Response to radiation and chemotherapy was manifested by development of a central low density region with an enhancing rim. CT findings correlated with clinical and cerebrospinal fluid findings. The differential diagnosis of the various abnormalities is considered

  8. Electronics for the Donner 600-Crystal Positron Tomograph

    International Nuclear Information System (INIS)

    Cahoon, J.L.; Huesman, R.H.; Derenzo, S.E.; Geyer, A.B.; Uber, D.C.; Turko, B.T.; Budinger, T.F.

    1985-10-01

    The data acquisition system, designed for the Donner 600-Crystal Positron Tomograph, is described. Coincidence timing resolution of less than five nanoseconds full width at half maximum and data rates in excess of one million events per second are achieved by using high-speed emitter coupled logic circuits, first-in first-out memory to derandomize data flow, and parallel architecture to increase throughput. These data rates allow the acquisition of adequate transmission data in a reasonable amount of time. Good timing resolution minimizes accidental coincidences and permits data rates greater than 100,000 image-forming events per second for high-speed dynamic emission tomography. Additional scatter and accidental rejection are accomplished for transmission data by using an orbiting source and a look-up table for valid events. Calibration of this complex electronic system is performed automatically under computer control. 4 refs., 5 figs

  9. Combination tomographic and cardiographic ultrasonic imaging method and system

    International Nuclear Information System (INIS)

    Yano, T.; Fukukita, H.; Fukumoto, A.; Hayakawa, Y.; Irioka, K.

    1984-01-01

    Ultrasonic echo signals are successively sampled and converted to digital echo data which are written into a first digital memory column by column and then read out row by row into a first buffer memory. The digital echo data which are derived in response to beams successively transmitted in a predetermined direction are written into columns of a second digital memory and read out of the memory in rows into a second buffer memory. The data stored in the first and second buffer memories are read out for digital-to-analog conversion and selectively applied within a television ''frame'' interval to control electron beam intensity of a single cathode ray tube so as to present tomographic and cardiographic images in different display areas of the tube

  10. Scanning tomographic particle image velocimetry applied to a turbulent jet

    KAUST Repository

    Casey, T. A.

    2013-02-21

    We introduce a modified tomographic PIV technique using four high-speed video cameras and a scanning pulsed laser-volume. By rapidly illuminating adjacent subvolumes onto separate video frames, we can resolve a larger total volume of velocity vectors, while retaining good spatial resolution. We demonstrate this technique by performing time-resolved measurements of the turbulent structure of a round jet, using up to 9 adjacent volume slices. In essence this technique resolves more velocity planes in the depth direction by maintaining optimal particle image density and limiting the number of ghost particles. The total measurement volumes contain between 1 ×106 and 3 ×106 velocity vectors calculated from up to 1500 reconstructed depthwise image planes, showing time-resolved evolution of the large-scale vortical structures for a turbulent jet of Re up to 10 000.

  11. Design of a femtosecond laser assisted tomographic atom probe

    International Nuclear Information System (INIS)

    Gault, B.; Vurpillot, F.; Vella, A.; Gilbert, M.; Menand, A.; Blavette, D.; Deconihout, B.

    2006-01-01

    A tomographic atom probe (TAP) in which the atoms are field evaporated by means of femtosecond laser pulses has been designed. It is shown that the field evaporation is assisted by the laser field enhanced by the subwavelength dimensions of the specimen without any significant heating of the specimen. In addition, as compared with the conventional TAP, due to the very short duration of laser pulses, no spread in the energy of emitted ions is observed, leading to a very high mass resolution in a straight TAP in a wide angle configuration. At last, laser pulses can be used to bring the intense electric field required for the field evaporation on poor conductive materials such as intrinsic Si at low temperature. In this article, the performance of the laser TAP is described and illustrated through the investigation of metals, oxides, and silicon materials

  12. The electronics for the Donner 600-Crystal Positron Tomograph

    International Nuclear Information System (INIS)

    Cahoon, J.L.; Huesman, R.H.; Derenzo, S.E.; Geyer, A.B.; Uber, D.C.; Turko, B.T.; Budinger, T.F.

    1986-01-01

    The data acquisition system, designed for the Donner 600-Crystal Positron Tomograph, is described. Coincidence timing resolution of less than five nanoseconds full width at half maximum and data rates in excess of one million events per second are achieved by using high-speed emitter coupled logic circuits, first-in first-out memory to derandomize data flow, and parallel architecture to increase throughput. These data rates allow the acquisition of adequate transmission data in a reasonable amount of time. Good timing resolution minimizes accidental coincidences and permits data rates greater than 100,000 image-forming events per second for high-speed dynamic emission tomography. Additional scatter and accidental rejection are accomplished for transmission data by using an orbiting source and a look-up table for valid events. Calibration of this complex electronic system is performed automatically under computer control

  13. The accuracy of the ATLAS muon X-ray tomograph

    Science.gov (United States)

    Avramidou, R.; Berbiers, J.; Boudineau, C.; Dechelette, C.; Drakoulakos, D.; Fabjan, C.; Grau, S.; Gschwendtner, E.; Maugain, J.-M.; Rieder, H.; Rangod, S.; Rohrbach, F.; Sbrissa, E.; Sedykh, E.; Sedykh, I.; Smirnov, Y.; Vertogradov, L.; Vichou, I.

    2003-01-01

    A gigantic detector, the ATLAS project, is under construction at CERN for particle physics research at the Large Hadron Collider which is to be ready by 2006. An X-ray tomograph has been developed, designed and constructed at CERN in order to control the mechanical quality of the ATLAS muon chambers. We reached a measurement accuracy of 2 μm systematic and 2 μm statistical uncertainties in the horizontal and vertical directions in the working area 220 cm (horizontal)×60 cm (vertical). Here we describe in detail the fundamental approach of the basic principle chosen to achieve such good accuracy. In order to crosscheck our precision, key results of measurements are presented.

  14. The accuracy of the ATLAS muon X-ray tomograph

    International Nuclear Information System (INIS)

    Avramidou, R.; Berbiers, J.; Boudineau, C.; Dechelette, C.; Drakoulakos, D.; Fabjan, C.; Grau, S.; Gschwendtner, E.; Maugain, J.-M.; Rieder, H.; Rangod, S.; Rohrbach, F.; Sbrissa, E.; Sedykh, E.; Sedykh, I.; Smirnov, Y.; Vertogradov, L.; Vichou, I.

    2003-01-01

    A gigantic detector, the ATLAS project, is under construction at CERN for particle physics research at the Large Hadron Collider which is to be ready by 2006. An X-ray tomograph has been developed, designed and constructed at CERN in order to control the mechanical quality of the ATLAS muon chambers. We reached a measurement accuracy of 2 μm systematic and 2 μm statistical uncertainties in the horizontal and vertical directions in the working area 220 cm (horizontal)x60 cm (vertical). Here we describe in detail the fundamental approach of the basic principle chosen to achieve such good accuracy. In order to crosscheck our precision, key results of measurements are presented

  15. Alveolar echinococcosis of the liver - computed tomographic findings

    International Nuclear Information System (INIS)

    Merkle, E.; Usadel, S.; Vogel, J.; Kern, P.; Friedrich, J.M.; Brambs, H.J.

    1995-01-01

    In order to ascertain the typical computed tomographic findings of hepatic alveolar echinococcosis, 24 computed tomograms of 19 patients were evaluated. The liver was involved in all cases whereas the diaphragma was infiltrated in 32%, and the retroperioteneal area in 42%. The right liver lobe was affected in 65%. Both before and after intravenous bolus contrast medium administration, the lesions were mainly inhomogeneous and of low density; a masking of the lesions due to the contrast medium administration was not observed; the enhancement pattern was irregular. Calcifications were detected in 96% of the cases, cystic structures in 50%, and cholestasis in 54%. On the basis of the crucial finding of calcifications in combination with the other typical observations, CT seems to be very suitable for the evaluation of hepatic alveolar echinococcosis. (orig.) [de

  16. Low-dose computed tomographic imaging in orbital trauma

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, A.; Whitehouse, R.W. (Manchester Univ. (United Kingdom). Dept. of Diagnostic Radiology)

    1993-08-01

    The authors review findings in 75 computed tomographic (CT) examinations of 66 patients with orbital trauma who were imaged using a low-radiation-dose CT technique. Imaging was performed using a dynamic scan mode and exposure factors of 120 kVp and 80 mAs resulting in a skin dose of 11 mGy with an effective dose-equivalent of 0.22 mSv. Image quality was diagnostic in all cases and excellent in 73 examinations. Soft-tissue abnormalities within the orbit including muscle adhesions were well demonstrated both on primary axial and reconstructed multiplanar images. The benefits of multiplanar reconstructions are stressed and the contribution of soft-tissue injuries to symptomatic diplopia examined. (author).

  17. Computed tomographic findings in children with spastic diplegia

    International Nuclear Information System (INIS)

    Yokochi, Kenji; Horie, Masayo; Inukai, Kazuhisa; Kito, Hideyuki; Shimabukuro, Satoshi; Kodama, Kazuo.

    1989-01-01

    Computed tomographic findings of 46 children with spastic diplegia examined at nine months to three years of age corrected for preterm births were analyzed. Both the size of the lateral ventricles measured by the width of the anterior horns, and the volume of the extracerebral low-density areas were enlarged in some patiens. Both enlargements did not, however, correlate to the severity of the motor abnormality in the patients. The low-density areas of the periventricular white matter, especially adjacent to the trigone, were reduced in many children, probably due to the atrophy of the cerebral white matter having periventricular leukomalacia. The anterior expansion of the white matter reduction from the trigone corresponded to the severer motor abnormality in the children with spastic diplegia. (author)

  18. Tomographic study of temporomandibular joints before orthodontic treatment

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Ki Jeong [Kyung Hee Univ. College of Dentistry, Seoul (Korea, Republic of)

    2001-12-15

    To determine whether there is a relationship between abnormal temporomandibular joint radiographic findings and age or gender in a sample of preorthodontic patients. Individualized corrected sagittal tomographs of 188 temporomandibular joints in 94 preorthodontic patients, aged 11 to 29 years, were taken and viewed by an observer blinded to clinical records. The study population was divided into 2 aged groups (11-15 years and 16-29 years) for comparative purpose. Temporomandibular joint radiographic findings were classified as normal or abnormal. There was no difference in ratio of abnormal to normal findings between the both aged groups. The frequency of osseous abnormalities was similar with that of abnormalities of condylar position. Abnormalities in CP and JS were most frequent in all aged groups. There is no significant difference between ages or genders for temporomandibular joint radiographic abnormalities.

  19. Detectability in the presence of computed tomographic reconstruction noise

    International Nuclear Information System (INIS)

    Hanson, K.M.

    1977-01-01

    The multitude of commercial computed tomographic (CT) scanners which have recently been introduced for use in diagnostic radiology has given rise to a need to compare these different machines in terms of image quality and dose to the patient. It is therefore desirable to arrive at a figure of merit for a CT image which gives a measure of the diagnostic efficacy of that image. This figure of merit may well be dependent upon the specific visual task being performed. It is clearly important that the capabilities and deficiencies of the human observer as well as the interface between man and machine, namely the viewing system, be taken into account in formulating the figure of merit. Since the CT reconstruction is the result of computer processing, it is possible to use this processing to alter the characteristics of the displayed images. This image processing may improve or degrade the figure of merit

  20. Longitudinal and transverse digital image reconstruction with a tomographic scanner

    International Nuclear Information System (INIS)

    Pickens, D.R.; Price, R.R.; Erickson, J.J.; Patton, J.A.; Partain, C.L.; Rollo, F.D.

    1981-01-01

    A Siemens Gammasonics PHO/CON-192 Multiplane Imager is interfaced to a digital computer for the purpose of performing tomographic reconstructions from the data collected during a single scan. Data from the two moving gamma cameras as well as camera position information are sent to the computer by an interface designed in the authors' laboratory. Backprojection reconstruction is implemented by the computer. Longitudinal images in whole-body format as well as smaller formats are reconstructed for up to six planes simultaneously from the list mode data. Transverse reconstructions are demonstrated for 201 T1 myocardial scans. Post-reconstruction deconvolution processing to remove the blur artifact (characteristic of focal plane tomography) is applied to a multiplane phantom. Digital data acquisition of data and reconstruction of images are practical, and can extend the usefulness of the machine when compared with the film output (author)

  1. A maximum entropy reconstruction technique for tomographic particle image velocimetry

    International Nuclear Information System (INIS)

    Bilsky, A V; Lozhkin, V A; Markovich, D M; Tokarev, M P

    2013-01-01

    This paper studies a novel approach for reducing tomographic PIV computational complexity. The proposed approach is an algebraic reconstruction technique, termed MENT (maximum entropy). This technique computes the three-dimensional light intensity distribution several times faster than SMART, using at least ten times less memory. Additionally, the reconstruction quality remains nearly the same as with SMART. This paper presents the theoretical computation performance comparison for MENT, SMART and MART, followed by validation using synthetic particle images. Both the theoretical assessment and validation of synthetic images demonstrate significant computational time reduction. The data processing accuracy of MENT was compared to that of SMART in a slot jet experiment. A comparison of the average velocity profiles shows a high level of agreement between the results obtained with MENT and those obtained with SMART. (paper)

  2. Matching tomographic IMRT fields with static photon fields

    International Nuclear Information System (INIS)

    Sethi, A.; Leybovich, L.; Dogan, N.; Emami, B.

    2001-01-01

    The matching of abutting radiation fields presents a challenging problem in radiation therapy. Due to sharp penumbra of linear accelerator beams, small (1-2 mm) errors in field positioning can lead to large (>30%) hot or cold spots in the abutment region. With head and neck immobilization devices (thermoplastic mask/aquaplast) an average setup error of 3 mm has been reported. Therefore hot or cold spots approaching 50% of the prescription dose may occur along the matchline. Although abutting radiation fields have been investigated for static fields, there is no reported study regarding matching of tomographic IMRT and static fields. Compared to static fields, the matching of tomographic IMRT fields with static fields is more complicated. Since IMRT and static fields are planned on separate treatment planning computers, the dose in the abutment region is not specified. In addition, commonly used techniques for matching fields, such as feathering of junctions, are not practical. We have developed a method that substantially reduces dose inhomogeneity in the abutment region. In this method, a 'buffer zone' around the matchline was created and was included as part of the target for both IMRT and static field plans. In both fields, a small dose gradient (≤3%/mm) in the buffer zone was created. In the IMRT plan, the buffer zone was divided into three sections with dose varying from 83% to 25% of prescription dose. The static field dose profile was modified using either a specially designed physical (hard) or a dynamic (soft) wedge. When these modified fields were matched, the combined dose in the abutment region varied by ≤10% in the presence of setup errors spanning 4 mm (±2 mm) when the hard wedge was used and 10 mm (±5 mm) with the soft wedge

  3. Pre-Clinical Medical Students' Exposure to and Attitudes Toward Pharmaceutical Industry Marketing.

    Science.gov (United States)

    Fein, Eric H; Vermillion, Michelle L; Uijtdehaage, Sebastian H J

    2007-12-01

    Background - Recent studies have examined the exposures and attitudes of physicians and third- and fourth-year medical students toward pharmaceutical industry marketing, but fewer studies have addressed these topics among pre-clinical medical students. Thus, the purpose of this study was to assess pre-clinical students' level of exposure to the pharmaceutical industry and their attitudes toward marketing. Method - First and second-year medical students at UCLA completed a 40-item survey based on previous studies. Results - Over three quarters of pre-clinical students (78.5% or 226 of 288) responded to the survey. Exposure to pharmaceutical industry marketing started very early in medical school. Most second-year students (77%) had received gifts including drug samples after three semesters. Most felt that this would not affect their future prescribing behavior. Conclusions - These findings and findings from related studies, coupled with the students' desire to learn more about the issue, suggest that an early educational intervention addressing this topic may be warranted in American medical schools.

  4. The preclinical discovery and development of quetiapine for the treatment of mania and depression.

    Science.gov (United States)

    Miranda, Aline Silva de; Moreira, Fabrício A; Teixeira, Antônio Lúcio

    2017-05-01

    Bipolar disorder is a chronic disabling condition characterized by alternating manic and depressive episodes. Bipolar disorder has been associated with functional impairment, poor quality of life, morbidity and mortality. Despite its significant clinical, social and economic burden, treatment options for bipolar disorder are still limited. Several clinical trials have shown efficacy of the atypical antipsychotic quetiapine (QTP) in the treatment of this condition. However, the mechanisms underlying the antidepressant and anti-manic effects of QTP remain poorly understood. Areas covered: The article provides the emerging evidence from pre-clinical studies regarding the antidepressant and anti-manic mechanisms of action of QTP. In combination with its primary active metabolite norquetiapine, QTP modulates several neurotransmitter systems, including serotonin, dopamine, noradrenaline and histamine. QTP also seems to influence mediators of the immune system. Expert opinion: Pre-clinical studies have provided valuable information on the potential antidepressant mechanisms of action of QTP, but pre-clinical studies on QTP's anti-manic effects are still scarce. A major problem refers to the lack of valid experimental models for bipolar disorder. Additionally, immune and genetic based studies are largely descriptive. The role of the QTP metabolite norquetiapine in modulating non-neurotransmitter systems also needs to be further addressed.

  5. Preclinical magnetic resonance imaging and systems biology in cancer research: current applications and challenges.

    Science.gov (United States)

    Albanese, Chris; Rodriguez, Olga C; VanMeter, John; Fricke, Stanley T; Rood, Brian R; Lee, YiChien; Wang, Sean S; Madhavan, Subha; Gusev, Yuriy; Petricoin, Emanuel F; Wang, Yue

    2013-02-01

    Biologically accurate mouse models of human cancer have become important tools for the study of human disease. The anatomical location of various target organs, such as brain, pancreas, and prostate, makes determination of disease status difficult. Imaging modalities, such as magnetic resonance imaging, can greatly enhance diagnosis, and longitudinal imaging of tumor progression is an important source of experimental data. Even in models where the tumors arise in areas that permit visual determination of tumorigenesis, longitudinal anatomical and functional imaging can enhance the scope of studies by facilitating the assessment of biological alterations, (such as changes in angiogenesis, metabolism, cellular invasion) as well as tissue perfusion and diffusion. One of the challenges in preclinical imaging is the development of infrastructural platforms required for integrating in vivo imaging and therapeutic response data with ex vivo pathological and molecular data using a more systems-based multiscale modeling approach. Further challenges exist in integrating these data for computational modeling to better understand the pathobiology of cancer and to better affect its cure. We review the current applications of preclinical imaging and discuss the implications of applying functional imaging to visualize cancer progression and treatment. Finally, we provide new data from an ongoing preclinical drug study demonstrating how multiscale modeling can lead to a more comprehensive understanding of cancer biology and therapy. Copyright © 2013 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  6. Monochromatic minibeam radiotherapy: theoretical and experimental dosimetry for preclinical treatment plans

    Energy Technology Data Exchange (ETDEWEB)

    Deman, P; Vautrin, M; Stupar, V; Barbier, E L; Elleaume, H; Esteve, F; Adam, J F, E-mail: adam@esrf.fr [INSERM, U836, BP 170, Grenoble Cedex 9, F-38042 (France)

    2011-07-21

    Monochromatic x-ray minibeam radiotherapy is a new radiosurgery approach based on arrays of submillimetric interlaced planar x-ray beams. The aim of this study was to characterize the dose distributions obtained with this new modality when being used for preclinical trials. Monte Carlo simulations were performed in water phantoms. Percentage depth-dose curves and dose profiles were computed for single incidences and interleaved incidences of 80 keV planar x-ray minibeam (0.6 x 5 mm) arrays. Peak to valley dose ratios were also computed at various depths for an increasing number of minibeams. 3D experimental polymer gel (nPAG) dosimetry measurements were performed using MRI devices designed for small animal imaging. These very high spatial resolution (50 {mu}m) dose maps were compared to the simulations. Preclinical minibeams dose distributions were fully characterized. Experimental dosimetry correlated well with Monte Carlo calculations (Student t-tests: p > 0.1). F98 tumor-bearing rats were also irradiated with interleaved minibeams (80 keV, prescribed dose: 25 Gy). This associated preclinical trial serves as a proof of principle of the technique. The mean survival time of irradiated glioma-bearing rats increased significantly, when compared to the untreated animals (59.6 {+-} 2.8 days versus 28.25 {+-} 0.75 days, p < 0.001).

  7. Deep Machine Learning Application to the Detection of Preclinical Neurodegenerative Diseases of Aging

    Directory of Open Access Journals (Sweden)

    Mathew J. Summers

    2017-12-01

    Full Text Available Artificial intelligence (AI deep learning protocols offer solutions to complex data processing and analysis. Increasingly these solutions are being applied in the healthcare field, most commonly in processing complex medical imaging data used for diagnosis. Current models apply AI to screening populations of patients for markers of disease and report detection accuracy rates exceeding those of human data screening. In this paper, we explore an alternate model for AI deployment, that of monitoring and analysing an individual’s level of function over time. In adopting this approach, we propose that AI may provide highly accurate and reliable detection of preclinical disease states associated with aging-related neurodegenerative diseases. One of the key challenges facing clinical detection of preclinical phases of diseases such as dementia is the high degree of inter-individual variability in aging-related changes to cognitive function. AI based monitoring of an individual over time offers the potential for the early detection of change in function for the individual, rather than relying on comparing the individual’s performance to population norms. We explore an approach to developing AI platforms for individual monitoring and preclinical disease detection and examine the potential benefits to the stakeholders in this technological development.

  8. Diagnostic accuracy of multi-slice computed tomographic angiography in the detection of cerebral aneurysms

    International Nuclear Information System (INIS)

    Haghighatkhah, H. R.; Sabouri, S.; Borzouyeh, F.; Bagherzadeh, M. H.; Bakhshandeh, H.; Jalali, A. H.

    2008-01-01

    Multislice computed tomographic angiography is a rapid and minimally invasive method for the detection of intracranial aneurysms. The purpose of this study was to compare Multislice computed tomographic angiography with digital subtraction angiography In the diagnosis of cerebral aneurysms. Patients and Methods: In this cross sectional study we evaluated 111 consecutive patients [42(37.8%) male and 69(62.2%) female], who were admitted under clinical symptoms and signs. suggestive of harboring an intracranial aneurysm by using a four detector Multislice computed tomographic angiography. Then we compared results of Multislice computed tomographic angiography with digital subtraction angiography results as a gold standard method. Digital subtraction angiography was performed by bilateral selective common carotid artery injections and either unilateral or bilateral vertebral artery injections, as necessary. Multislice computed tomographic angiography images were interpreted by one radiologist and digital subtraction angiography was performed by another radiologist who was blinded to the interpretation of the Multislice computed tomographic angiograms. Results: The mean ±S D age of the patients was 49.1±13.6 years (range: 12-84 years). We performed Multislice computed tomographic in 111 and digital subtraction angiography in 85 patients. The sensitivity, specificity, positive predictive value, negative predictive value, positive and negative likelihood ratio of Multislice computed tomographic angiography, when compared with digital subtraction angiography as the gold standard, were 100%, 90%, 87.5%, 100%, 10 and 0, respectively. Conclusion: Multislice computed tomographic angiography seems to be an accurate and noninvasive imaging modality in the diagnosis of intracranial aneurysms

  9. Stroke Lesions in a Large Upper Limb Rehabilitation Trial Cohort Rarely Match Lesions in Common Preclinical Models

    Science.gov (United States)

    Edwardson, Matthew A.; Wang, Ximing; Liu, Brent; Ding, Li; Lane, Christianne J.; Park, Caron; Nelsen, Monica A.; Jones, Theresa A; Wolf, Steven L; Winstein, Carolee J; Dromerick, Alexander W.

    2017-01-01

    Background Stroke patients with mild-moderate upper extremity (UE) motor impairments and minimal sensory and cognitive deficits provide a useful model to study recovery and improve rehabilitation. Laboratory-based investigators use lesioning techniques for similar goals. Objective Determine whether stroke lesions in an UE rehabilitation trial cohort match lesions from the preclinical stroke recovery models used to drive translational research. Methods Clinical neuroimages from 297 participants enrolled in the Interdisciplinary Comprehensive Arm Rehabilitation Evaluation (ICARE) study were reviewed. Images were characterized based on lesion type (ischemic or hemorrhagic), volume, vascular territory, depth (cortical gray matter, cortical white matter, subcortical), old strokes, and leukoaraiosis. Lesions were compared with those of preclinical stroke models commonly used to study upper limb recovery. Results Among the ischemic stroke participants, median infarct volume was 1.8 mL, with most lesions confined to subcortical structures (61%) including the anterior choroidal artery territory (30%) and the pons (23%). Of ICARE participants, stroke patients, but they represent a clinically and scientifically important subgroup. Compared to lesions in general stroke populations and widely-studied animal models of recovery, ICARE participants had smaller, more subcortically-based strokes. Improved preclinical-clinical translational efforts may require better alignment of lesions between preclinical and human stroke recovery models. PMID:28337932

  10. Characterization of novel preclinical dose distributions for micro irradiator

    International Nuclear Information System (INIS)

    Kodra, J; Miles, D; Yoon, S W; Kirsch, D G; Oldham, M

    2017-01-01

    This work explores and demonstrates the feasibility of utilizing new 3D printing techniques to implement advanced micro radiation therapy for pre-clinical small animal studies. 3D printed blocks and compensators were designed and printed from a strong x-ray attenuating material at sub-millimeter resolution. These techniques enable a powerful range of new preclinical treatment capabilities including grid therapy, lattice therapy, and IMRT treatment. At small scales, verification of these treatments is exceptionally challenging, and high resolution 3D dosimetry (0.5mm 3 ) is an essential capability to characterize and verify these capabilities, Here, investigate the 2D and 3D dosimetry of several novel pre-clinical treatments using a combination of EBT film and Presage/optical-CT 3D dosimetry in rodent-morphic dosimeters. (paper)

  11. Characterization of novel preclinical dose distributions for micro irradiator

    Science.gov (United States)

    Kodra, J.; Miles, D.; Yoon, S. W.; Kirsch, D. G.; Oldham, M.

    2017-05-01

    This work explores and demonstrates the feasibility of utilizing new 3D printing techniques to implement advanced micro radiation therapy for pre-clinical small animal studies. 3D printed blocks and compensators were designed and printed from a strong x-ray attenuating material at sub-millimeter resolution. These techniques enable a powerful range of new preclinical treatment capabilities including grid therapy, lattice therapy, and IMRT treatment. At small scales, verification of these treatments is exceptionally challenging, and high resolution 3D dosimetry (0.5mm3) is an essential capability to characterize and verify these capabilities, Here, investigate the 2D and 3D dosimetry of several novel pre-clinical treatments using a combination of EBT film and Presage/optical-CT 3D dosimetry in rodent-morphic dosimeters.

  12. Construction of a positron emission tomograph with 2.4 mm detectors

    International Nuclear Information System (INIS)

    McIntyre, J.A.; Sprosst, R.L.; Wang, K.

    1986-01-01

    One-quarter of one ring of a positron tomograph has been constructed. The positron annihilation gamma rays are detected by polished plastic scintillators which direct scintillation light by internal reflection to optical fibers for transmission to the photo-multiplier tubes. By viewing each scintillator with four sets of optical fibers, the number of photomultipliers required for an eight ring tomograph with 1024 detectors per ring (2.4 mm wide detectors) can be reduced from 8192 to 288, and the cost of the tomograph reduced accordingly

  13. Kinetic modeling in pre-clinical positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kuntner, Claudia [AIT Austrian Institute of Technology GmbH, Seibersdorf (Austria). Biomedical Systems, Health and Environment Dept.

    2014-07-01

    Pre-clinical positron emission tomography (PET) has evolved in the last few years from pure visualization of radiotracer uptake and distribution towards quantification of the physiological parameters. For reliable and reproducible quantification the kinetic modeling methods used to obtain relevant parameters of radiotracer tissue interaction are important. Here we present different kinetic modeling techniques with a focus on compartmental models including plasma input models and reference tissue input models. The experimental challenges of deriving the plasma input function in rodents and the effect of anesthesia are discussed. Finally, in vivo application of kinetic modeling in various areas of pre-clinical research is presented and compared to human data.

  14. The basics of preclinical drug development for neurodegenerative disease indications.

    Science.gov (United States)

    Steinmetz, Karen L; Spack, Edward G

    2009-06-12

    Preclinical development encompasses the activities that link drug discovery in the laboratory to initiation of human clinical trials. Preclinical studies can be designed to identify a lead candidate from several hits; develop the best procedure for new drug scale-up; select the best formulation; determine the route, frequency, and duration of exposure; and ultimately support the intended clinical trial design. The details of each preclinical development package can vary, but all have some common features. Rodent and nonrodent mammalian models are used to delineate the pharmacokinetic profile and general safety, as well as to identify toxicity patterns. One or more species may be used to determine the drug's mean residence time in the body, which depends on inherent absorption, distribution, metabolism, and excretion properties. For drugs intended to treat Alzheimer's disease or other brain-targeted diseases, the ability of a drug to cross the blood brain barrier may be a key issue. Toxicology and safety studies identify potential target organs for adverse effects and define the Therapeutic Index to set the initial starting doses in clinical trials. Pivotal preclinical safety studies generally require regulatory oversight as defined by US Food and Drug Administration (FDA) Good Laboratory Practices and international guidelines, including the International Conference on Harmonization. Concurrent preclinical development activities include developing the Clinical Plan and preparing the new drug product, including the associated documentation to meet stringent FDA Good Manufacturing Practices regulatory guidelines. A wide range of commercial and government contract options are available for investigators seeking to advance their candidate(s). Government programs such as the Small Business Innovative Research and Small Business Technology Transfer grants and the National Institutes of Health Rapid Access to Interventional Development Pilot Program provide funding and

  15. The basics of preclinical drug development for neurodegenerative disease indications

    Directory of Open Access Journals (Sweden)

    Spack Edward G

    2009-06-01

    Full Text Available Abstract Preclinical development encompasses the activities that link drug discovery in the laboratory to initiation of human clinical trials. Preclinical studies can be designed to identify a lead candidate from several hits; develop the best procedure for new drug scale-up; select the best formulation; determine the route, frequency, and duration of exposure; and ultimately support the intended clinical trial design. The details of each preclinical development package can vary, but all have some common features. Rodent and nonrodent mammalian models are used to delineate the pharmacokinetic profile and general safety, as well as to identify toxicity patterns. One or more species may be used to determine the drug's mean residence time in the body, which depends on inherent absorption, distribution, metabolism, and excretion properties. For drugs intended to treat Alzheimer's disease or other brain-targeted diseases, the ability of a drug to cross the blood brain barrier may be a key issue. Toxicology and safety studies identify potential target organs for adverse effects and define the Therapeutic Index to set the initial starting doses in clinical trials. Pivotal preclinical safety studies generally require regulatory oversight as defined by US Food and Drug Administration (FDA Good Laboratory Practices and international guidelines, including the International Conference on Harmonisation. Concurrent preclinical development activities include developing the Clinical Plan and preparing the new drug product, including the associated documentation to meet stringent FDA Good Manufacturing Practices regulatory guidelines. A wide range of commercial and government contract options are available for investigators seeking to advance their candidate(s. Government programs such as the Small Business Innovative Research and Small Business Technology Transfer grants and the National Institutes of Health Rapid Access to Interventional Development Pilot

  16. A crowdsourcing model for creating preclinical medical education study tools.

    Science.gov (United States)

    Bow, Hansen C; Dattilo, Jonathan R; Jonas, Andrea M; Lehmann, Christoph U

    2013-06-01

    During their preclinical course work, medical students must memorize and recall substantial amounts of information. Recent trends in medical education emphasize collaboration through team-based learning. In the technology world, the trend toward collaboration has been characterized by the crowdsourcing movement. In 2011, the authors developed an innovative approach to team-based learning that combined students' use of flashcards to master large volumes of content with a crowdsourcing model, using a simple informatics system to enable those students to share in the effort of generating concise, high-yield study materials. The authors used Google Drive and developed a simple Java software program that enabled students to simultaneously access and edit sets of questions and answers in the form of flashcards. Through this crowdsourcing model, medical students in the class of 2014 at the Johns Hopkins University School of Medicine created a database of over 16,000 questions that corresponded to the Genes to Society basic science curriculum. An analysis of exam scores revealed that students in the class of 2014 outperformed those in the class of 2013, who did not have access to the flashcard system, and a survey of students demonstrated that users were generally satisfied with the system and found it a valuable study tool. In this article, the authors describe the development and implementation of their crowdsourcing model for creating study materials, emphasize its simplicity and user-friendliness, describe its impact on students' exam performance, and discuss how students in any educational discipline could implement a similar model of collaborative learning.

  17. Bioluminescence Tomography–Guided Radiation Therapy for Preclinical Research

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Bin [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins School of Medicine, Baltimore, Maryland (United States); Wang, Ken Kang-Hsin, E-mail: kwang27@jhmi.edu [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins School of Medicine, Baltimore, Maryland (United States); Yu, Jingjing [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins School of Medicine, Baltimore, Maryland (United States); School of Physics and Information Technology, Shaanxi Normal University, Shaanxi (China); Eslami, Sohrab; Iordachita, Iulian [Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, Maryland (United States); Reyes, Juvenal; Malek, Reem [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins School of Medicine, Baltimore, Maryland (United States); Tran, Phuoc T. [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins School of Medicine, Baltimore, Maryland (United States); Department of Oncology and Urology, Brady Urological Institute, Johns Hopkins University, Baltimore, Maryland (United States); Patterson, Michael S. [Department of Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, Ontario (Canada); Wong, John W. [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins School of Medicine, Baltimore, Maryland (United States)

    2016-04-01

    Purpose: In preclinical radiation research, it is challenging to localize soft tissue targets based on cone beam computed tomography (CBCT) guidance. As a more effective method to localize soft tissue targets, we developed an online bioluminescence tomography (BLT) system for small-animal radiation research platform (SARRP). We demonstrated BLT-guided radiation therapy and validated targeting accuracy based on a newly developed reconstruction algorithm. Methods and Materials: The BLT system was designed to dock with the SARRP for image acquisition and to be detached before radiation delivery. A 3-mirror system was devised to reflect the bioluminescence emitted from the subject to a stationary charge-coupled device (CCD) camera. Multispectral BLT and the incomplete variables truncated conjugate gradient method with a permissible region shrinking strategy were used as the optimization scheme to reconstruct bioluminescent source distributions. To validate BLT targeting accuracy, a small cylindrical light source with high CBCT contrast was placed in a phantom and also in the abdomen of a mouse carcass. The center of mass (CoM) of the source was recovered from BLT and used to guide radiation delivery. The accuracy of the BLT-guided targeting was validated with films and compared with the CBCT-guided delivery. In vivo experiments were conducted to demonstrate BLT localization capability for various source geometries. Results: Online BLT was able to recover the CoM of the embedded light source with an average accuracy of 1 mm compared to that with CBCT localization. Differences between BLT- and CBCT-guided irradiation shown on the films were consistent with the source localization revealed in the BLT and CBCT images. In vivo results demonstrated that our BLT system could potentially be applied for multiple targets and tumors. Conclusions: The online BLT/CBCT/SARRP system provides an effective solution for soft tissue targeting, particularly for small, nonpalpable, or

  18. Bioluminescence Tomography–Guided Radiation Therapy for Preclinical Research

    International Nuclear Information System (INIS)

    Zhang, Bin; Wang, Ken Kang-Hsin; Yu, Jingjing; Eslami, Sohrab; Iordachita, Iulian; Reyes, Juvenal; Malek, Reem; Tran, Phuoc T.; Patterson, Michael S.; Wong, John W.

    2016-01-01

    Purpose: In preclinical radiation research, it is challenging to localize soft tissue targets based on cone beam computed tomography (CBCT) guidance. As a more effective method to localize soft tissue targets, we developed an online bioluminescence tomography (BLT) system for small-animal radiation research platform (SARRP). We demonstrated BLT-guided radiation therapy and validated targeting accuracy based on a newly developed reconstruction algorithm. Methods and Materials: The BLT system was designed to dock with the SARRP for image acquisition and to be detached before radiation delivery. A 3-mirror system was devised to reflect the bioluminescence emitted from the subject to a stationary charge-coupled device (CCD) camera. Multispectral BLT and the incomplete variables truncated conjugate gradient method with a permissible region shrinking strategy were used as the optimization scheme to reconstruct bioluminescent source distributions. To validate BLT targeting accuracy, a small cylindrical light source with high CBCT contrast was placed in a phantom and also in the abdomen of a mouse carcass. The center of mass (CoM) of the source was recovered from BLT and used to guide radiation delivery. The accuracy of the BLT-guided targeting was validated with films and compared with the CBCT-guided delivery. In vivo experiments were conducted to demonstrate BLT localization capability for various source geometries. Results: Online BLT was able to recover the CoM of the embedded light source with an average accuracy of 1 mm compared to that with CBCT localization. Differences between BLT- and CBCT-guided irradiation shown on the films were consistent with the source localization revealed in the BLT and CBCT images. In vivo results demonstrated that our BLT system could potentially be applied for multiple targets and tumors. Conclusions: The online BLT/CBCT/SARRP system provides an effective solution for soft tissue targeting, particularly for small, nonpalpable, or

  19. Implementierung und Evaluierung eines tutoriell betreuten elektronischen Biochemie-Praktikumsversuchs "Polymerase-Kettenreaktion (PCR" im vorklinischen Studienabschnitt [Implementation and Evaluation of a Tutor-Supported Computer-Based Practical Biochemistry Course "Polymerase Chain Reaction (PCR" in Preclinical Education

    Directory of Open Access Journals (Sweden)

    Kröncke, Klaus-Dietrich

    2008-08-01

    Full Text Available [english] Background: The polymerase chain reaction (PCR is an example of a technology that for many medical students is not easy to understand. We investigated whether a tutor-supported e-learning teaching unit is suitable to teach undergraduate medical students the PCR. Methods: We developed a computer-based practical course (attendance is compulsory that uses an open source-based system as a learning platform. The students learned to search in scientific medical databases to find PCR-relevant data. In addition, they learned the essential features of the PCR with the aid of embedded textual information and audiovisual animations. To check that the learning objectives were fulfilled, the students had to solve medical-related PCR tasks on the computer. Results: In total, 311 students went through the course. They were satisfied with the e-learning teaching unit and evaluated it very positively, independently of their prior knowledge concerning the PCR. Students with low levels of computer skills did not feel over-challenged. Conclusion: Our results show that a computer-based practical training course is an excellent option for teaching undergraduate medical students complex technologies that could otherwise only be taught in a laboratory at great expense of time and effort. [german] Zielsetzung: Es sollte untersucht werden, ob ein E-Learning Praktikumsversuch geeignet ist, Medizin-Studierenden der Vorklinik die Polymerase-Kettenreaktion (PCR begreiflich zu machen. Methodik: Ein Computer-basierter Praktikumsversuch wurde entwickelt, der sowohl das Recherchieren in wissenschaftlich-medizinischen Datenbanken zum Auffinden von PCR-relevanten Informationen beinhaltet als auch Selbstlerneinheiten über die PCR. Als Lernzielkontrollen dienten Aufgaben aus der medizinischen PCR-Diagnostik. Die Akzeptanz der Lehrveranstaltung bei den Studierenden wurde mit einem Fragebogen ermittelt, der 19 Items enthielt. Ergebnisse: 311 Studierende absolvierten den

  20. Preclinical evaluation of severely defective manganese-based nanocrystal as a liver-specific contrast media for MR imaging: comparison with Gd-EOB-DTPA and MnDPDP

    Science.gov (United States)

    Zhang, Yu; Xiao, Xiao-ping; Shu, Ting; Cai, Jing; Xiao, Xin-lan; Li, Yan-shu; Zhang, Zhong-wei; Tang, Qun

    2018-06-01

    Manganese-based (chemically formulated of KMnF3) nanocrystal was evaluated as a liver-specific contrast agent for MR imaging and its imaging performance was also compared with those of two commercial hepatobiliary contrast media (Gd-EOB-DTPA and MnDPDP). KMnF3 nanocrystal was post-treated using a plasma technique to cause severe defects, leading to appropriate water dispersibility and high relaxivity. Severely defective KMnF3 nanocrystal (SD-KMnF3) has characteristic high tolerance, as evidenced by cytotoxicity on the macrophage cell, and acute and subchronic toxicity on the healthy mouse. SD-KMnF3 showed better hepatic MR imaging as the T 1 relaxation time of the liver decreased to only 17% of the control group, compared to 22% of the control group for Gd-EOB-DTPA (P hepatocarcinoma or metastatic lesions.

  1. Circulating mitochondrial DNA as biomarker linking environmental chemical exposure to early preclinical lesions elevation of mtDNA in human serum after exposure to carcinogenic halo-alkane-based pesticides.

    Directory of Open Access Journals (Sweden)

    Lygia T Budnik

    Full Text Available There is a need for a panel of suitable biomarkers for detection of environmental chemical exposure leading to the initiation or progression of degenerative diseases or potentially, to cancer. As the peripheral blood may contain increased levels of circulating cell-free DNA in diseased individuals, we aimed to evaluate this DNA as effect biomarker recognizing vulnerability after exposure to environmental chemicals. We recruited 164 individuals presumably exposed to halo-alkane-based pesticides. Exposure evaluation was based on human biomonitoring analysis; as biomarker of exposure parent halo-methanes, -ethanes and their metabolites, as well as the hemoglobin-adducts methyl valine and hydroxyl ethyl valine in blood were used, complemented by expert evaluation of exposure and clinical intoxication symptoms as well as a questionnaire. Assessment showed exposures to halo alkanes in the concentration range being higher than non-cancer reference doses (RfD but (mostly lower than the occupational exposure limits. We quantified circulating DNA in serum from 86 individuals with confirmed exposure to off-gassing halo-alkane pesticides (in storage facilities or in home environment and 30 non-exposed controls, and found that exposure was significantly associated with elevated serum levels of circulating mitochondrial DNA (in size of 79 bp, mtDNA-79, p = 0.0001. The decreased integrity of mtDNA (mtDNA-230/mtDNA-79 in exposed individuals implicates apoptotic processes (p = 0.015. The relative amounts of mtDNA-79 in serum were positively associated with the lag-time after intoxication to these chemicals (r = 0.99, p<0.0001. Several months of post-exposure the specificity of this biomarker increased from 30% to 97% in patients with intoxication symptoms. Our findings indicate that mitochondrial DNA has a potential to serve as a biomarker recognizing vulnerable risk groups after exposure to toxic/carcinogenic chemicals.

  2. Central tarsal bone fractures in horses not used for racing: Computed tomographic configuration and long-term outcome of lag screw fixation

    OpenAIRE

    Gunst, S; Del Chicca, Francesca; Fürst, Anton; Kuemmerle, Jan M

    2016-01-01

    REASONS FOR PERFORMING STUDY: There are no reports on the configuration of equine central tarsal bone fractures based on cross-sectional imaging and clinical and radiographic long-term outcome after internal fixation. OBJECTIVES: To report clinical, radiographic and computed tomographic findings of equine central tarsal bone fractures and to evaluate the long-term outcome of internal fixation. STUDY DESIGN: Retrospective case series. METHODS: All horses diagnosed with a central tarsa...

  3. Project, building and utilization of a tomograph of micro metric resolution to application in soil science

    International Nuclear Information System (INIS)

    Macedo, Alvaro; Torre Neto, Andre; Cruvinel, Paulo Estevao; Crestana, Silvio

    1996-08-01

    This paper describes the project , building and utilization of a tomograph of micro metric resolution in soil science. It describes the problems involved in soil's science study and it describes the system and methodology

  4. Tomographic apparatus for reconstructing planar slices from non-absorbed and non-scattered radiation

    International Nuclear Information System (INIS)

    1980-01-01

    Apparatus which can be used in computerized tomographic systems for producing a fan shaped beam, detectors to be used in conjunction with the source and equipment for rotating the source supports are described. (U.K.)

  5. IceBridge Radar L3 Tomographic Ice Thickness V001

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set contains Level-3 tomographic ice thickness measurements derived from data captured by the Center for Remote Sensing of Ice Sheets (CReSIS) Multichannel...

  6. Blunt oesophageal perforation: treatment with surgical exclusion and percutaneous drainage under computed tomographic guidance

    International Nuclear Information System (INIS)

    Vauthey, J.N.; Lerut, J.; Laube, M.; Gertsch, P.

    1992-01-01

    We report a patient with a left thoracic contusion and rupture of the distal oesophagus. Persistent sepsis developed after oesophageal exclusion without closure. Two collection were drained percutaneously under computed tomographic guidance and the sepsis resolved. (11 refs., 1 fig.)

  7. Remote diagnosis via a telecommunication satellite--ultrasonic tomographic image transmission experiments.

    Science.gov (United States)

    Nakajima, I; Inokuchi, S; Tajima, T; Takahashi, T

    1985-04-01

    An experiment to transmit ultrasonic tomographic section images required for remote medical diagnosis and care was conducted using the mobile telecommunication satellite OSCAR-10. The images received showed the intestinal condition of a patient incapable of verbal communication, however the image screen had a fairly coarse particle structure. On the basis of these experiments, were considered as the transmission of ultrasonic tomographic images extremely effective in remote diagnosis.

  8. Novel epigenetic target therapy for prostate cancer: a preclinical study.

    Directory of Open Access Journals (Sweden)

    Ilaria Naldi

    Full Text Available Epigenetic events are critical contributors to the pathogenesis of cancer, and targeting epigenetic mechanisms represents a novel strategy in anticancer therapy. Classic demethylating agents, such as 5-Aza-2'-deoxycytidine (Decitabine, hold the potential for reprograming somatic cancer cells demonstrating high therapeutic efficacy in haematological malignancies. On the other hand, epigenetic treatment of solid tumours often gives rise to undesired cytotoxic side effects. Appropriate delivery systems able to enrich Decitabine at the site of action and improve its bioavailability would reduce the incidence of toxicity on healthy tissues. In this work we provide preclinical evidences of a safe, versatile and efficient targeted epigenetic therapy to treat hormone sensitive (LNCap and hormone refractory (DU145 prostate cancers. A novel Decitabine formulation, based on the use of engineered erythrocyte (Erythro-Magneto-Hemagglutinin Virosomes, EMHVs drug delivery system (DDS carrying this drug, has been refined. Inside the EMHVs, the drug was shielded from the environment and phosphorylated in its active form. The novel magnetic EMHV DDS, endowed with fusogenic protein, improved the stability of the carried drug and exhibited a high efficiency in confining its delivery at the site of action in vivo by applying an external static magnetic field. Here we show that Decitabine loaded into EMHVs induces a significant tumour mass reduction in prostate cancer xenograft models at a concentration, which is seven hundred times lower than the therapeutic dose, suggesting an improved pharmacokinetics/pharmacodynamics of drug. These results are relevant for and discussed in light of developing personalised autologous therapies and innovative clinical approach for the treatment of solid tumours.

  9. Novel epigenetic target therapy for prostate cancer: a preclinical study.

    Science.gov (United States)

    Naldi, Ilaria; Taranta, Monia; Gherardini, Lisa; Pelosi, Gualtiero; Viglione, Federica; Grimaldi, Settimio; Pani, Luca; Cinti, Caterina

    2014-01-01

    Epigenetic events are critical contributors to the pathogenesis of cancer, and targeting epigenetic mechanisms represents a novel strategy in anticancer therapy. Classic demethylating agents, such as 5-Aza-2'-deoxycytidine (Decitabine), hold the potential for reprograming somatic cancer cells demonstrating high therapeutic efficacy in haematological malignancies. On the other hand, epigenetic treatment of solid tumours often gives rise to undesired cytotoxic side effects. Appropriate delivery systems able to enrich Decitabine at the site of action and improve its bioavailability would reduce the incidence of toxicity on healthy tissues. In this work we provide preclinical evidences of a safe, versatile and efficient targeted epigenetic therapy to treat hormone sensitive (LNCap) and hormone refractory (DU145) prostate cancers. A novel Decitabine formulation, based on the use of engineered erythrocyte (Erythro-Magneto-Hemagglutinin Virosomes, EMHVs) drug delivery system (DDS) carrying this drug, has been refined. Inside the EMHVs, the drug was shielded from the environment and phosphorylated in its active form. The novel magnetic EMHV DDS, endowed with fusogenic protein, improved the stability of the carried drug and exhibited a high efficiency in confining its delivery at the site of action in vivo by applying an external static magnetic field. Here we show that Decitabine loaded into EMHVs induces a significant tumour mass reduction in prostate cancer xenograft models at a concentration, which is seven hundred times lower than the therapeutic dose, suggesting an improved pharmacokinetics/pharmacodynamics of drug. These results are relevant for and discussed in light of developing personalised autologous therapies and innovative clinical approach for the treatment of solid tumours.

  10. Alzheimer's disease and age-related memory decline (preclinical).

    Science.gov (United States)

    Terry, Alvin V; Callahan, Patrick M; Hall, Brandon; Webster, Scott J

    2011-08-01

    An unfortunate result of the rapid rise in geriatric populations worldwide is the increasing prevalence of age-related cognitive disorders such as Alzheimer's disease (AD). AD is a devastating neurodegenerative illness that is characterized by a profound impairment of cognitive function, marked physical disability, and an enormous economic burden on the afflicted individual, caregivers, and society in general. The rise in elderly populations is also resulting in an increase in individuals with related (potentially treatable) conditions such as "Mild Cognitive Impairment" (MCI) which is characterized by a less severe (but abnormal) level of cognitive impairment and a high-risk for developing dementia. Even in the absence of a diagnosable disorder of cognition (e.g., AD and MCI), the perception of increased forgetfulness and declining mental function is a clear source of apprehension in the elderly. This is a valid concern given that even a modest impairment of cognitive function is likely to be associated with significant disability in a rapidly evolving, technology-based society. Unfortunately, the currently available therapies designed to improve cognition (i.e., for AD and other forms of dementia) are limited by modest efficacy and adverse side effects, and their effects on cognitive function are not sustained over time. Accordingly, it is incumbent on the scientific community to develop safer and more effective therapies that improve and/or sustain cognitive function in the elderly allowing them to remain mentally active and productive for as long as possible. As diagnostic criteria for memory disorders evolve, the demand for pro-cognitive therapeutic agents is likely to surpass AD and dementia to include MCI and potentially even less severe forms of memory decline. The purpose of this review is to provide an overview of the contemporary therapeutic targets and preclinical pharmacologic approaches (with representative drug examples) designed to enhance memory

  11. Pipelining Computational Stages of the Tomographic Reconstructor for Multi-Object Adaptive Optics on a Multi-GPU System

    KAUST Repository

    Charara, Ali

    2014-11-01

    The European Extremely Large Telescope project (E-ELT) is one of Europe\\'s highest priorities in ground-based astronomy. ELTs are built on top of a variety of highly sensitive and critical astronomical instruments. In particular, a new instrument called MOSAIC has been proposed to perform multi-object spectroscopy using the Multi-Object Adaptive Optics (MOAO) technique. The core implementation of the simulation lies in the intensive computation of a tomographic reconstruct or (TR), which is used to drive the deformable mirror in real time from the measurements. A new numerical algorithm is proposed (1) to capture the actual experimental noise and (2) to substantially speed up previous implementations by exposing more concurrency, while reducing the number of floating-point operations. Based on the Matrices Over Runtime System at Exascale numerical library (MORSE), a dynamic scheduler drives all computational stages of the tomographic reconstruct or simulation and allows to pipeline and to run tasks out-of order across different stages on heterogeneous systems, while ensuring data coherency and dependencies. The proposed TR simulation outperforms asymptotically previous state-of-the-art implementations up to 13-fold speedup. At more than 50000 unknowns, this appears to be the largest-scale AO problem submitted to computation, to date, and opens new research directions for extreme scale AO simulations. © 2014 IEEE.

  12. Stress, Burnout and Coping Strategies in Preclinical Medical Students

    Science.gov (United States)

    Fares, Jawad; Al Tabosh, Hayat; Saadeddin, Zein; El Mouhayyar, Christopher; Aridi, Hussam

    2016-01-01

    It is acknowledged that physicians do not seek the same expert aid for themselves as they would offer their patients. In their preclinical years, medical students appear to espouse comparable behavior. To many, medicine is described as a never-ending path that places the student under heavy stress and burnout from the beginning, leaving him/her vulnerable and with insufficient coping methods. Hence, the objective of this study is to 1) explore the prevalence of stress and burnout among preclinical medical students, and 2) propose solutions to decrease stress and burnout and improve medical education in the preclinical years. A detailed scholarly research strategy using Google Scholar, Scopus, Embase, MEDLINE and PubMed was implemented to highlight key themes that are relevant to preclinical medical students’ stress and burnout. Stress varied among different samples of medical students and ranged between 20.9% and 90%. Conversely, burnout ranged between 27% and 75%. Methods that help in reducing the incidence of stress and burnout by promoting strategies that focus on personal engagement, extracurricular activities, positive reinterpretation and expression of emotion, student-led mentorship programs, evaluation systems, career counseling and life coaching should be adopted. PMID:27042604

  13. A preclinical mouse model of invasive lobular breast cancer metastasis

    NARCIS (Netherlands)

    Doornebal, Chris W.; Klarenbeek, Sjoerd; Braumuller, Tanya M.; Klijn, Christiaan N.; Ciampricotti, Metamia; Hau, Cheei-Sing; Hollmann, Markus W.; Jonkers, Jos; de Visser, Karin E.

    2013-01-01

    Metastatic disease accounts for more than 90% of cancer-related deaths, but the development of effective antimetastatic agents has been hampered by the paucity of clinically relevant preclinical models of human metastatic disease. Here, we report the development of a mouse model of spontaneous

  14. Stress, Burnout and Coping Strategies in Preclinical Medical Students.

    Science.gov (United States)

    Fares, Jawad; Al Tabosh, Hayat; Saadeddin, Zein; El Mouhayyar, Christopher; Aridi, Hussam

    2016-02-01

    It is acknowledged that physicians do not seek the same expert aid for themselves as they would offer their patients. In their preclinical years, medical students appear to espouse comparable behavior. To many, medicine is described as a never-ending path that places the student under heavy stress and burnout from the beginning, leaving him/her vulnerable and with insufficient coping methods. Hence, the objective of this study is to 1) explore the prevalence of stress and burnout among preclinical medical students, and 2) propose solutions to decrease stress and burnout and improve medical education in the preclinical years. A detailed scholarly research strategy using Google Scholar, Scopus, Embase, MEDLINE and PubMed was implemented to highlight key themes that are relevant to preclinical medical students' stress and burnout. Stress varied among different samples of medical students and ranged between 20.9% and 90%. Conversely, burnout ranged between 27% and 75%. Methods that help in reducing the incidence of stress and burnout by promoting strategies that focus on personal engagement, extracurricular activities, positive reinterpretation and expression of emotion, student-led mentorship programs, evaluation systems, career counseling and life coaching should be adopted.

  15. Nanotechnology and nuclear medicine; research and preclinical applications.

    Science.gov (United States)

    Assadi, Majid; Afrasiabi, Kolsoom; Nabipour, Iraj; Seyedabadi, Mohammad

    2011-01-01

    The birth of nanotechnology in human society was around 2000 years ago and soon found applications in various fields. In this article, we highlight the current status of research and preclinical applications and also future prospects of nanotechnology in medicine and in nuclear medicine. The most important field is cancer. A regular nanotechnology training program for nuclear medicine physicians may be welcome.

  16. USHERING IN THE STUDY AND TREATMENT OF PRECLINICAL ALZHEIMER DISEASE

    Science.gov (United States)

    Langbaum, Jessica B.S.; Fleisher, Adam S.; Chen, Kewei; Ayutyanont, Napatkamon; Lopera, Francisco; Quiroz, Yakeel T.; Caselli, Richard J.; Tariot, Pierre N.; Reiman, Eric M.

    2014-01-01

    Researchers have begun to characterize the subtle biological and cognitive processes that precede the clinical onset of Alzheimer disease (AD), and to set the stage for accelerated evaluation of experimental treatments to delay the onset, reduce the risk of or completely prevent clinical decline. Here, we provide an overview of the experimental strategies, and brain imaging and cerebrospinal fluid biomarker measures that are used in early detection and tracking of AD, highlighting at-risk individuals who could be suitable for preclinical monitoring. We discuss how these advances have contributed to reconceptualization of AD as a sequence of biological changes that occur during progression from preclinical AD, to mild cognitive impairment and finally dementia, and we review recently proposed research criteria for preclinical AD. Advances in the study of preclinical AD have driven the recognition that efficacy of at least some AD therapies may depend on initiation of treatment before clinical manifestation of disease, leading to a new era of AD prevention research. PMID:23752908

  17. Image-guided drug delivery: preclinical applications and clinical translation

    NARCIS (Netherlands)

    Ojha, Tarun; Rizzo, Larissa; Storm, Gerrit; Kiessling, Fabian; Lammers, Twan Gerardus Gertudis Maria

    2015-01-01

    Image-guided drug delivery refers to the combination of drug targeting and imaging. Preclinically, image-guided drug delivery can be used for several different purposes, including for monitoring biodistribution, target site accumulation, off-target localization, drug release and drug efficacy.

  18. Applicability of a set of tomographic reconstruction algorithms for quantitative SPECT on irradiated nuclear fuel assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Jacobsson Svärd, Staffan, E-mail: staffan.jacobsson_svard@physics.uu.se; Holcombe, Scott; Grape, Sophie

    2015-05-21

    A fuel assembly operated in a nuclear power plant typically contains 100–300 fuel rods, depending on fuel type, which become strongly radioactive during irradiation in the reactor core. For operational and security reasons, it is of interest to experimentally deduce rod-wise information from the fuel, preferably by means of non-destructive measurements. The tomographic SPECT technique offers such possibilities through its two-step application; (1) recording the gamma-ray flux distribution around the fuel assembly, and (2) reconstructing the assembly's internal source distribution, based on the recorded radiation field. In this paper, algorithms for performing the latter step and extracting quantitative relative rod-by-rod data are accounted for. As compared to application of SPECT in nuclear medicine, nuclear fuel assemblies present a much more heterogeneous distribution of internal attenuation to gamma radiation than the human body, typically with rods containing pellets of heavy uranium dioxide surrounded by cladding of a zirconium alloy placed in water or air. This inhomogeneity severely complicates the tomographic quantification of the rod-wise relative source content, and the deduction of conclusive data requires detailed modelling of the attenuation to be introduced in the reconstructions. However, as shown in this paper, simplified models may still produce valuable information about the fuel. Here, a set of reconstruction algorithms for SPECT on nuclear fuel assemblies are described and discussed in terms of their quantitative performance for two applications; verification of fuel assemblies' completeness in nuclear safeguards, and rod-wise fuel characterization. It is argued that a request not to base the former assessment on any a priori information brings constraints to which reconstruction methods that may be used in that case, whereas the use of a priori information on geometry and material content enables highly accurate quantitative

  19. Positioning of Nuclear Fuel Assemblies by Means of Image Analysis on Tomographic Data

    International Nuclear Information System (INIS)

    Troeng, Mats

    2005-06-01

    A tomographic measurement technique for nuclear fuel assemblies has been developed at the Department of Radiation Sciences at Uppsala University. The technique requires highly accurate information about the position of the measured nuclear fuel assembly relative to the measurement equipment. In experimental campaigns performed earlier, separate positioning measurements have therefore been performed in connection to the tomographic measurements. In this work, another positioning approach has been investigated, which requires only the collection of tomographic data. Here, a simplified tomographic reconstruction is performed, whereby an image is obtained. By performing image analysis on this image, the lateral and angular position of the fuel assembly can be determined. The position information can then be used to perform a more accurate tomographic reconstruction involving detailed physical modeling. Two image analysis techniques have been developed in this work. The stability of the two techniques with respect to some central parameters has been studied. The agreement between these image analysis techniques and the previously used positioning technique was found to meet the desired requirements. Furthermore, it has been shown that the image analysis techniques offer more detailed information than the previous technique. In addition, its off-line analysis properties reduce the need for valuable measurement time. When utilizing the positions obtained from the image analysis techniques in tomographic reconstructions of the rod-by-rod power distribution, the repeatability of the reconstructed values was improved. Furthermore, the reconstructions resulted in better agreement to theoretical data

  20. A positron emission tomograph designed for 3/4 mm resolution

    International Nuclear Information System (INIS)

    McInytre, J.A.; Allen, R.D.; Aguiar, J.; Paulson, J.T.

    1995-01-01

    Two factors of the design for a positron tomograph affect the magnitude of the tomograph spatial resolution: the gamma ray detector width and the analogue measurement of the scintillator location. In the tomograph design reported here the analogue measurement is eliminated and the detector transaxial width factor is reduced to 3/4 mm. The analogue measurement is eliminated by transmitting the scintillation light from each individual scintillator through optical fibers to four photo-multipliers (PMT's); the identities of the PMT's then provide a digital address for the scintillation location. Plastic scintillators are used to provide enough scintillation light for transmission through the optical fibers. Bonuses from the use of plastic scintillators are first, the reduction of the scintillator dead time to about 10 nsec, second, a large reduction of cross-talk between neighboring scintillators, third, the reduction of resolution loss from off-axis gamma rays and, fourth, the ability to sample the axial image at one-eighth the axial resolution distance of 2.5 mm. The designed tomograph incorporates 20 rings. Two of the 32 tomograph 20-ring modules have been constructed to measure the resolution and other characteristics of the tomographs