WorldWideScience

Sample records for power saving strategies

  1. Strategies for Power/Energy Saving in Distribution Networks

    Directory of Open Access Journals (Sweden)

    GRIGORAS, G.

    2010-05-01

    Full Text Available The power/energy losses reduction in distribution systems is an important issue during planning and operation, with important technical and economical implications. Thus, the energy losses minimization implies not only the technical improvement of the network, through its renewal with the introduction of the technological innovations in the equipment and circuit components as well as the optimal planning of the design and development of the network, but also requires the use of the methods and software tools to facilitate the operation process. The paper presents a strategy for power/energy saving which replacement of the 6 kV voltage level with 20 kV voltage level in correlation with the extent of using efficient transformers. In this line, different urban distribution networks were analyzed using fuzzy techniques.

  2. Mission aware energy saving strategies for Army ground vehicles

    Science.gov (United States)

    Dattathreya, Macam S.

    Fuel energy is a basic necessity for this planet and the modern technology to perform many activities on earth. On the other hand, quadrupled automotive vehicle usage by the commercial industry and military has increased fuel consumption. Military readiness of Army ground vehicles is very important for a country to protect its people and resources. Fuel energy is a major requirement for Army ground vehicles. According to a report, a department of defense has spent nearly $13.6 billion on fuel and electricity to conduct ground missions. On the contrary, energy availability on this plant is slowly decreasing. Therefore, saving energy in Army ground vehicles is very important. Army ground vehicles are embedded with numerous electronic systems to conduct missions such as silent and normal stationary surveillance missions. Increasing electrical energy consumption of these systems is influencing higher fuel consumption of the vehicle. To save energy, the vehicles can use any of the existing techniques, but they require complex, expensive, and time consuming implementations. Therefore, cheaper and simpler approaches are required. In addition, the solutions have to save energy according to mission needs and also overcome size and weight constraints of the vehicle. Existing research in the current literature do not have any mission aware approaches to save energy. This dissertation research proposes mission aware online energy saving strategies for stationary Army ground vehicles to save energy as well as to meet the electrical needs of the vehicle during surveillance missions. The research also proposes theoretical models of surveillance missions, fuzzy logic models of engine and alternator efficiency data, and fuzzy logic algorithms. Based on these models, two energy saving strategies are proposed for silent and normal surveillance type of missions. During silent mission, the engine is on and batteries power the systems. During normal surveillance mission, the engine is

  3. ONU Power Saving Scheme for EPON System

    Science.gov (United States)

    Mukai, Hiroaki; Tano, Fumihiko; Tanaka, Masaki; Kozaki, Seiji; Yamanaka, Hideaki

    PON (Passive Optical Network) achieves FTTH (Fiber To The Home) economically, by sharing an optical fiber among plural subscribers. Recently, global climate change has been recognized as a serious near term problem. Power saving techniques for electronic devices are important. In PON system, the ONU (Optical Network Unit) power saving scheme has been studied and defined in XG-PON. In this paper, we propose an ONU power saving scheme for EPON. Then, we present an analysis of the power reduction effect and the data transmission delay caused by the ONU power saving scheme. According to the analysis, we propose an efficient provisioning method for the ONU power saving scheme which is applicable to both of XG-PON and EPON.

  4. Energy Savings Calculations for Heat Island Reduction Strategies in Baton Rouge, Sacramento and Salt Lake City

    Energy Technology Data Exchange (ETDEWEB)

    Konopacki, S.; Akbari, H.

    2000-03-01

    In 1997, the US Environmental Protection Agency (EPA) established the ''Heat Island Reduction Initiative'', to quantify the potential benefits of Heat Island Reduction (HIR) strategies (i.e., shade trees, reflective roofs, reflective pavements and urban vegetation) to reduce cooling energy use in buildings, lower the ambient air temperature and improve urban air quality in cities, and reduce CO2 emissions from power plants. Under this initiative, the Urban Heat Island Pilot Project (UHIPP) was created with the objective to investigate the potential of HIR strategies in residential and commercial buildings in three initial UHIPP cities: Baton Rouge, Sacramento and Salt Lake City. This paper summarizes our efforts to calculate the annual energy savings, peak power avoidance and annual C02 reduction of HIR strategies in the three initial cities. In this analysis, we focused on three building types that offer most savings potential: single-family residence, office and retail store. Each building type was characterized in detail by old or new construction and with a gas furnace or an electric heat pump. We defined prototypical building characteristics for each building type and simulated the impact of HIR strategies on building cooling and heating energy use and peak power demand using the DOE-2.IE model. Our simulations included the impact of (1) strategically-placed shade trees near buildings [direct effect], (2) use of high-albedo roofing material on building [direct effect], (3) combined strategies I and 2 [direct effect], (4) urban reforestation with high-albedo pavements and building surfaces [indirect effect] and (5) combined strategies 1, 2 and 4 [direct and indirect effects]. We then estimated the total roof area of air-conditioned buildings in each city using readily obtainable data to calculate the metropolitan-wide impact of HIR strategies. The results show, that in Baton Rouge, potential annual energy savings of $15M could be realized by

  5. Long-run savings and investment strategy optimization.

    Science.gov (United States)

    Gerrard, Russell; Guillén, Montserrat; Nielsen, Jens Perch; Pérez-Marín, Ana M

    2014-01-01

    We focus on automatic strategies to optimize life cycle savings and investment. Classical optimal savings theory establishes that, given the level of risk aversion, a saver would keep the same relative amount invested in risky assets at any given time. We show that, when optimizing lifecycle investment, performance and risk assessment have to take into account the investor's risk aversion and the maximum amount the investor could lose, simultaneously. When risk aversion and maximum possible loss are considered jointly, an optimal savings strategy is obtained, which follows from constant rather than relative absolute risk aversion. This result is fundamental to prove that if risk aversion and the maximum possible loss are both high, then holding a constant amount invested in the risky asset is optimal for a standard lifetime saving/pension process and outperforms some other simple strategies. Performance comparisons are based on downside risk-adjusted equivalence that is used in our illustration.

  6. Long-Run Savings and Investment Strategy Optimization

    Directory of Open Access Journals (Sweden)

    Russell Gerrard

    2014-01-01

    Full Text Available We focus on automatic strategies to optimize life cycle savings and investment. Classical optimal savings theory establishes that, given the level of risk aversion, a saver would keep the same relative amount invested in risky assets at any given time. We show that, when optimizing lifecycle investment, performance and risk assessment have to take into account the investor’s risk aversion and the maximum amount the investor could lose, simultaneously. When risk aversion and maximum possible loss are considered jointly, an optimal savings strategy is obtained, which follows from constant rather than relative absolute risk aversion. This result is fundamental to prove that if risk aversion and the maximum possible loss are both high, then holding a constant amount invested in the risky asset is optimal for a standard lifetime saving/pension process and outperforms some other simple strategies. Performance comparisons are based on downside risk-adjusted equivalence that is used in our illustration.

  7. Saving Energy and Money: A Lesson in Computer Power Management

    Science.gov (United States)

    Lazaros, Edward J.; Hua, David

    2012-01-01

    In this activity, students will develop an understanding of the economic impact of technology by estimating the cost savings of power management strategies in the classroom. Students will learn how to adjust computer display settings to influence the impact that the computer has on the financial burden to the school. They will use mathematics to…

  8. Energy saving and consumption reducing evaluation of thermal power plant

    Science.gov (United States)

    Tan, Xiu; Han, Miaomiao

    2018-03-01

    At present, energy saving and consumption reduction require energy saving and consumption reduction measures for thermal power plant, establishing an evaluation system for energy conservation and consumption reduction is instructive for the whole energy saving work of thermal power plant. By analysing the existing evaluation system of energy conservation and consumption reduction, this paper points out that in addition to the technical indicators of power plant, market activities should also be introduced in the evaluation of energy saving and consumption reduction in power plant. Ttherefore, a new evaluation index of energy saving and consumption reduction is set up and the example power plant is calculated in this paper. Rresults show that after introducing the new evaluation index of energy saving and consumption reduction, the energy saving effect of the power plant can be judged more comprehensively, so as to better guide the work of energy saving and consumption reduction in power plant.

  9. Water Saving Strategies & Ecological Modernisation

    DEFF Research Database (Denmark)

    Hoffmann, Birgitte; Jensen, Jesper Ole; Elle, Morten

    2005-01-01

    Drawing on case studies of water saving campaigns and new collaborations, the pa-per will serve, on the one hand, as an interpretation of the water saving strategy in Co-penhagen in the light of Ecological Modernisation, and on the other hand, as a critical discussion of Ecological Modernisation...... as a frame for understanding resource manage-ment. The water management in Copenhagen has in recent years undergone a rather radi-cal transition. Along with strong drivers for resource management in the region the mu-nicipal water supplier has tested and implemented a number of initiatives to promote sus...... to 125 l/capita/day in 2002. A series of different strategies, targets and tools have been implemented: Emphasizing demand side instead of supply side, using and communicating indicators, formulating goals for reducing water consumption and developing learning processes in water management. A main...

  10. Heat Saving Strategies in Sustainable Smart Energy Systems

    DEFF Research Database (Denmark)

    Lund, Henrik; Thellufsen, Jakob Zinck; Aggerholm, Søren

    that a least‐cost strategy will be to provide approximately 2/3 of the heat demand from district heating and the rest from individual heat pumps. Keywords: Energy Efficiency, Renewable energy, Heating strategy, Heat savings, District heating, Smart energy......One of the important issues related to the implementation of future sustainable smart energy systems based on renewable energy sources is the heating of buildings. Especially, when it comes to long‐term investment in savings and heating infrastructures it is essential to identify long‐term least......‐cost strategies. With Denmark as a case, this paper investigates to which extent heat should be saved rather than produced and to which extent district heating infrastructures, rather than individual heating solutions, should be used. Based on a concrete proposal to implement the Danish governmental long...

  11. CROSS LAYER COORDINATED ENERGY SAVING STRATEGY IN MANET

    Institute of Scientific and Technical Information of China (English)

    Xu Li; Zheng Baoyu

    2003-01-01

    Mobile Ad hoc NETwork (MANET) consists of a set of mobile hosts which can operate independently without infrastructure base stations. Energy saving is a critical issue for MANET since most mobile hosts will operate on battery powers. A cross layer coordinated framework for energy saving is proposed in this letter. On-demand power management, physical layer and medium access control layer dialogue based multi-packet reception, mobile agent based topology discovery and topology control based transmit power-aware and battery power-aware dynamic source routing are some of new ideas in this framework.

  12. Enersave API: Android-based power-saving framework for mobile devices

    Directory of Open Access Journals (Sweden)

    A.M. Muharum

    2017-06-01

    Full Text Available Power consumption is a major factor to be taken into consideration when using mobile devices in the IoT field. Good Power management requires proper understanding of the way in which it is being consumed by the end-devices. This paper is a continuation of the work in Ref. [1] and proposes an energy saving API for the Android Operating System in order to help developers turn their applications into energy-aware ones. The main features heavily used for building smart applications, greatly impact battery life of Android devices and which have been taken into consideration are: Screen brightness, Colour scheme, CPU frequency, 2G/3G network, Maps, Low power localisation, Bluetooth and Wi-Fi. The assessment of the power-saving API has been performed on real Android devices and also compared to the most powerful power-saving applications – DU Battery Saver and Battery Saver 2016 – currently available on the Android market. Comparisons demonstrate that the Enersave API has a significant impact on power saving when incorporated in android applications. While DU Battery Saver and Battery Saver 2016 help saving 22.2% and 40.5% of the battery power respectively, the incorporation of the Enersave API in android applications can help save 84.6% of battery power.

  13. Streamlined energy-savings calculations for heat-island reduction strategies

    Energy Technology Data Exchange (ETDEWEB)

    Akbari, Hashem; Konopacki, Steven J.

    2003-03-15

    We have developed summary tables (sorted by heating- and cooling-degree-days) to estimate the potential of Heat-Island Reduction (HIR) strategies (i.e., solar-reflective roofs, shade trees, reflective pavements, and urban vegetation) to reduce cooling-energy use in buildings. The tables provide estimates of savings for both direct effect (reducing heat gain through the building shell) and indirect effect (reducing the ambient air temperature). In this analysis, we considered three building types that offer the most savings potential : residences, offices, and retail stores. Each building type was characterized in detail by Pre-1980 (old) or 1980+ (new) construction vintage and with natural gas or electricity as heating fuel. We defined prototypical-building characteristics for each building type and simulated the effects of HIR strategies on building cooling and heating energy use and peak power demand using the DOE-2.1E model and weather data for about 240 locations in the U.S. A statistical analysis of previously completed simulations for five cities was used to estimate the indirect savings. Our simulations included the effect of (1) solar-reflective roofing material on building [direct effect], (2) placement of deciduous shade trees near south and west walls of building [direct effect], and (3) ambient cooling achieved by urban reforestation and reflective building surfaces and pavements [indirect effect]. Upon completion of estimating the direct and indirect energy savings for all the selected locations, we integrated the results in tables arranged by heating- and cooling-degree-days. We considered 15 bins for heating-degree-days, and 11 bins for cooling-degree-days. Energy use and savings are presented per 1000 ft2 of roof area. In residences heated with gas and in climates with greater than 1000 cooling-degree-days, the annual electricity savings in Pre-1980 stock ranged from 650 to 1300 kWh/1000ft2; for 1980+ stock savings ranged 300 to 600 kWh/1000 ft2

  14. Heat Saving Strategies in Sustainable Smart Energy Systems

    DEFF Research Database (Denmark)

    Lund, Henrik; Thellufsen, Jakob Zinck; Aggerholm, Søren

    2014-01-01

    This paper investigates to which extent heat should be saved rather than produced and to which extent district heating infrastructures, rather than individual heating solutions, should be used in future sustainable smart energy systems. Based on a concrete proposal to implement the Danish...... governmental 2050 fossil-free vision, this paper identifies marginal heat production costs and compares these to marginal heat savings costs for two different levels of district heating. A suitable least-cost heating strategy seems to be to invest in an approximately 50% decrease in net heat demands in new...... buildings and buildings that are being renovated anyway, while the implementation of heat savings in buildings that are not being renovated hardly pays. Moreover, the analysis points in the direction that a least-cost strategy will be to provide approximately 2/3 of the heat demand from district heating...

  15. Effects of a power shortage in the Tokyo metropolitan area on awareness of nuclear power generation and power savings behavior

    International Nuclear Information System (INIS)

    Kitada, Atsuko

    2004-01-01

    The shutdown of a number of nuclear power stations of the Tokyo Electric Power Company in the summer of 2003 caused a power shortage problem in the Tokyo Metropolitan area. To examine the effects of the power shortage, in September 2003 a survey was conducted in the service areas of the Kansai Electric Power Company (Kansai region) and the Tokyo Electric Power Company (Kanto region). This survey was part of a wider opinion survey begun in 1993 concerning nuclear power generation. The results of the September 2003 survey are as follows: The degree of recognition of the power shortage problem in the Metropolitan area was high, with 40% of respondents in the Kansai region and nearly 70% in the Kanto region understanding that the shortage was caused by the shutdown of several nuclear power station. The overall awareness of nuclear power generation was little affected in both the Kansai and Kanto regions, though the sense of a shortage of the generating capacity had been raised slightly. Once respondents knew about the power shortage problem, they estimated the likelihood of an occurrence of large-scale service interruption to be low, nearly at an even chance, and they had been only slightly worried about it, essentially viewing the problem optimistically. In the Kanto region, where public relations activities for power savings had been actively pursued, the frequency of experiencing exposure to such public relations activities was remarkably higher than in the Kansai region. The relation between exposure to public relations activities for power savings and power savings behavior was analyzed using quantification method II. Analysis results suggest that public relations activities for power savings in the Kanto region had the effect of urging power savings behavior. However, the difference in the rate of putting power savings behavior into practice was small between the Kanto and Kansai regions, indicating that public relation activities for power savings in the Kanto

  16. Heat Saving Strategies in Sustainable Smart Energy Systems

    Directory of Open Access Journals (Sweden)

    Henrik Lund

    2014-06-01

    Full Text Available This paper investigates to which extent heat should be saved rather than produced and to which extent district heating infrastructures, rather than individual heating solutions, should be used in future sustainable smart energy systems. Based on a concrete proposal to implement the Danish governmental 2050 fossil-free vision, this paper identifies marginal heat production costs and compares these to marginal heat savings costs for two different levels of district heating. A suitable least-cost heating strategy seems to be to invest in an approximately 50% decrease in net heat demands in new buildings and buildings that are being renovated anyway, while the implementation of heat savings in buildings that are not being renovated hardly pays. Moreover, the analysis points in the direction that a least-cost strategy will be to provide approximately 2/3 of the heat demand from district heating and the rest from individual heat pumps.

  17. Saving doses by outage planning strategy and architectural arrangements

    International Nuclear Information System (INIS)

    Wahlstroem, B.

    1993-01-01

    All radiation doses come out as a result of dose rate and exposure time, and the main part of the occupational exposure is caused during outages. While every reasonable attempt should be made to lower the dose rates, the other factor, the exposure time, may not be forgotten. The paper presents possible ways of saving man-hours in the controlled zone by outage planning strategy. And every saved man-hour means a saved radiation dose. At Loviisa NPS also some special architectural arrangements contribute to shortening the outage time, thus saving doses

  18. Evolution of China's power dispatch principle and the new energy saving power dispatch policy

    International Nuclear Information System (INIS)

    Ciwei, Gao; Yang, Li

    2010-01-01

    With social economic reform in the past decades, the power industry of China is gradually evolving from a highly integrated one toward an electricity market, which can be characterized based on the transition of the power dispatch principle. To attract investment in the power generating industry, China introduced non-state-owned power plants to the original system of a highly vertically integrated power industry with annual power generation quota guarantees, which makes the traditional economic dispatch principle not applicable. The newly debuted energy saving power dispatch (ESPD) is an attempt to fully exploit the maximum energy savings and was implemented by an administrative code. Starting in August 2007, the pilot operation of the ESPD was implemented in five provinces, but after two years, it is still not widely applied all over the country. This paper details the transition of China's power dispatch principle with particular attention to its origin and content. Moreover, the factors that influence the ESPD's actual energy saving effect are discussed, as well as the sustainability of the policy. (author)

  19. Development of Android based Smart Power Saving System

    Science.gov (United States)

    Gupta, Ashutosh; Kumar, Pradeep; Ghosh, Tathagata; Bhawna, Shruthi. S.

    2017-08-01

    An android based smart power saving system has been presented in this paper. For this purpose, an application is developed for controlling the intensity of an AC supply using a dimmer circuit in android platform and to monitor the current flow on different intensity level a current sensor is used in the circuit. Dimmer circuit provides a 16-different intensity level to control the flow of current and help in power saving. The system is very simple and robust as it is based on android platform.

  20. Money in the bank : Feeling powerful increases saving

    NARCIS (Netherlands)

    Garbinsky, E.; Klesse, A.K.; Aaker, J.

    2014-01-01

    Across five studies, this research reveals that feeling powerful increases saving. This effect is driven by the desire to maintain one’s current state. When the purpose of saving is no longer to accumulate money but to spend it on a status-related product, the basic effect is reversed, and those who

  1. Integrated Power Saving for Multiple Relays and UEs in LTE-TDD

    OpenAIRE

    Chun-Chuan Yang; Jeng-Yueng Chen; Yi-Ting Mai; Chen-Ming Yang

    2017-01-01

    In this paper, the design of integrated sleep scheduling for relay nodes and user equipments under a Donor eNB (DeNB) in the mode of Time Division Duplex (TDD) in LTE-A is presented. The idea of virtual time is proposed to deal with the discontinuous pattern of the available radio resource in TDD, and based on the estimation of the traffic load, three power saving schemes in the top-down strategy are presented. Associated mechanisms in each scheme including calculation of the virtual subframe...

  2. A review of different strategies for HVAC energy saving

    International Nuclear Information System (INIS)

    Vakiloroaya, Vahid; Samali, Bijan; Fakhar, Ahmad; Pishghadam, Kambiz

    2014-01-01

    Highlights: • Various strategies for HVAC energy saving are described and reviewed. • The influence of each strategy on the HVAC energy saving is investigated. • Combination of existing air conditioning technologies appears to be effective for the energy conservation and comfort. • A comparison study between these approaches is carried out. • Changing the HVAC configuration has the potential to increase or reduce energy savings, depending on several factors. - Abstract: Decreasing the energy consumption of heating, ventilation and air conditioning (HVAC) systems is becoming increasingly important due to rising cost of fossil fuels and environmental concerns. Therefore, finding novel ways to reduce energy consumption in buildings without compromising comfort and indoor air quality is an ongoing research challenge. One proven way of achieving energy efficiency in HVAC systems is to design systems that use novel configurations of existing system components. Each HVAC discipline has specific design requirements and each presents opportunities for energy savings. Energy efficient HVAC systems can be created by re-configuring traditional systems to make more strategic use of existing system parts. Recent research has demonstrated that a combination of existing air conditioning technologies can offer effective solutions for energy conservation and thermal comfort. This paper investigates and reviews the different technologies and approaches, and demonstrates their ability to improve the performance of HVAC systems in order to reduce energy consumption. For each strategy, a brief description is first presented and then by reviewing the previous studies, the influence of that method on the HVAC energy saving is investigated. Finally, a comparison study between these approaches is carried out

  3. Electric power production contra electricity savings

    International Nuclear Information System (INIS)

    Schleisner, L.; Grohnheit, P.E.; Soerensen, H.

    1991-01-01

    The expansion of electricity-producing plants has, in Denmark until now, taken place in accordance with the demand for electricity. Recently, it has been suggested that the cost of the further development of such systems is greater than the cost of instigating and carrying out energy conservation efforts. The aim of the project was to evaluate the consequences for power producing plants of a reduction of the electricity consumption of end-users. A method for the analysis of the costs involved in the system and operation of power plants contra the costs that are involved in saving electricity is presented. In developing a model of this kind, consideration is given to the interplay of the individual saving project and the existing or future electricity supply. Thus it can be evaluated to what extent it would be advisable to substitute investments in the development of the capacity of the power plants with investments in the reduction of electricity consumption by the end users. This model is described in considerable detail. It will be tested in representative situations and locations throughout the Nordic countries. (AB) 17 refs

  4. Prospects for future uranium savings through LWRs with high performance cores

    International Nuclear Information System (INIS)

    Mochida, T.; Yamamoto, T.; Sasaki, M.; Matsuura, H.; Ueji, M.; Murata, T.; Kanda, K.; Oka, Y.; Kondo, S.

    1995-01-01

    Since 1986, Nuclear Power Engineering Cooperation (NUPEC) has been studying four types of LWR high performance core concepts (i.e., the uranium saving core I (USC-I), the uranium saving core II (USC-II), the high moderation core (HMC) and the low moderation core (LMC)), which aim at improvement of uranium and plutonium utilization. After the evaluation of fundamental core performance and uranium and plutonium material balance for each reactor, potential uranium savings with different reactor strategies are evaluated for the Japanese scenario with assumption of the growth of future nuclear power plant generation, annual reprocessing capacity and schedules for the introduction of high performance core. At 2030, about 3-6% savings in uranium demand are expected by USC-I or USC-II strategy, while about 14% savings by HMC strategy and about 8% by LMC strategy. (author)

  5. Intervention strategy to stimulate energy-saving behavior of local residents

    International Nuclear Information System (INIS)

    Han, Q.; Nieuwenhijsen, I.; Vries, B. de; Blokhuis, E.; Schaefer, W.

    2013-01-01

    This study investigates intervention strategy in stimulating energy-saving behavior to achieve energy neutral urban development. A tree structure overview of potential interventions classified into three categories is revealed. An integrated behaviour model is developed reflecting the relations between behaviour and influence factors. A latent class model is used to identify segments of local residents who differ regarding their preferences for interventions. Data are collected from a sample of residents in the Eindhoven region of the Netherlands in 2010. The results indicate that social-demographic characteristics, knowledge, motivation and context factors play important roles in energy-saving behaviour. Specifically, four segments of residents in the study area were identified that clearly differed in their preferences of interventions: cost driven residents, conscious residents, ease driven residents and environment minded residents. These findings emphasize that the intervention strategy should be focused on specific target groups to have the right mixture of interventions to achieve effective results on stimulating them to save energy. - Highlights: ► A latent class model to identify segments with preferred energy-saving interventions. ► An integrated energy-saving behavior model of casual relations. ► A tree structure overview of potential interventions

  6. Energy savings for heat-island reduction strategies in Chicago and Houston (including updates for Baton Rouge, Sacramento, and Salt Lake City); FINAL

    International Nuclear Information System (INIS)

    Konopacki, S.; Akbari, H.

    2002-01-01

    In 1997, the U.S. Environmental Protection Agency (EPA) established the ''Heat Island Reduction Initiative'' to quantify the potential benefits of Heat-Island Reduction (HIR) strategies (i.e., shade trees, reflective roofs, reflective pavements and urban vegetation) to reduce cooling-energy use in buildings, lower the ambient air temperature and improve urban air quality in cities, and reduce CO2 emissions from power plants. Under this initiative, the Urban Heat Island Pilot Project (UHIPP) was created with the objective of investigating the potential of HIR strategies in residential and commercial buildings in three initial UHIPP cities: Baton Rouge, LA; Sacramento, CA; and Salt Lake City, UT. Later two other cities, Chicago, IL and Houston, TX were added to the UHIPP. In an earlier report we summarized our efforts to calculate the annual energy savings, peak power avoidance, and annual CO2 reduction obtainable from the introduction of HIR strategies in the initial three cities. This report summarizes the results of our study for Chicago and Houston. In this analysis, we focused on three building types that offer the highest potential savings: single-family residence, office and retail store. Each building type was characterized in detail by vintage and system type (i.e., old and new building constructions, and gas and electric heat). We used the prototypical building characteristics developed earlier for each building type and simulated the impact of HIR strategies on building cooling- and heating-energy use and peak power demand using the DOE-2.1E model. Our simulations included the impact of (1) strategically-placed shade trees near buildings[direct effect], (2) use of high-albedo roofing material on the building[direct effect], (3) urban reforestation with high-albedo pavements and building surfaces[indirect effect] and (4) combined strategies 1, 2, and 3[direct and indirect effects]. We then estimated the total roof area of air-conditioned buildings in each

  7. Financial Impact of Cancer Drug Wastage and Potential Cost Savings From Mitigation Strategies.

    Science.gov (United States)

    Leung, Caitlyn Y W; Cheung, Matthew C; Charbonneau, Lauren F; Prica, Anca; Ng, Pamela; Chan, Kelvin K W

    2017-07-01

    Cancer drug wastage occurs when a parenteral drug within a fixed vial is not administered fully to a patient. This study investigated the extent of drug wastage, the financial impact on the hospital budget, and the cost savings associated with current mitigation strategies. We conducted a cross-sectional study in three University of Toronto-affiliated hospitals of various sizes. We recorded the actual amount of drug wasted over a 2-week period while using current mitigation strategies. Single-dose vial cancer drugs with the highest wastage potentials were identified (14 drugs). To calculate the hypothetical drug wastage with no mitigation strategies, we determined how many vials of drugs would be needed to fill a single prescription. The total drug costs over the 2 weeks ranged from $50,257 to $716,983 in the three institutions. With existing mitigation strategies, the actual drug wastage over the 2 weeks ranged from $928 to $5,472, which was approximately 1% to 2% of the total drug costs. In the hypothetical model with no mitigation strategies implemented, the projected drug cost wastage would have been $11,232 to $149,131, which accounted for 16% to 18% of the total drug costs. As a result, the potential annual savings while using current mitigation strategies range from 15% to 17%. The financial impact of drug wastage is substantial. Mitigation strategies lead to substantial cost savings, with the opportunity to reinvest those savings. More research is needed to determine the appropriate methods to minimize risk to patients while using the cost-saving mitigation strategies.

  8. Energy savings for heat-island reduction strategies in Chicago and Houston (including updates for Baton Rouge, Sacramento, and Salt Lake City)

    Energy Technology Data Exchange (ETDEWEB)

    Konopacki, S.; Akbari, H.

    2002-02-28

    In 1997, the U.S. Environmental Protection Agency (EPA) established the ''Heat Island Reduction Initiative'' to quantify the potential benefits of Heat-Island Reduction (HIR) strategies (i.e., shade trees, reflective roofs, reflective pavements and urban vegetation) to reduce cooling-energy use in buildings, lower the ambient air temperature and improve urban air quality in cities, and reduce CO2 emissions from power plants. Under this initiative, the Urban Heat Island Pilot Project (UHIPP) was created with the objective of investigating the potential of HIR strategies in residential and commercial buildings in three initial UHIPP cities: Baton Rouge, LA; Sacramento, CA; and Salt Lake City, UT. Later two other cities, Chicago, IL and Houston, TX were added to the UHIPP. In an earlier report we summarized our efforts to calculate the annual energy savings, peak power avoidance, and annual CO2 reduction obtainable from the introduction of HIR strategies in the initial three cities. This report summarizes the results of our study for Chicago and Houston. In this analysis, we focused on three building types that offer the highest potential savings: single-family residence, office and retail store. Each building type was characterized in detail by vintage and system type (i.e., old and new building constructions, and gas and electric heat). We used the prototypical building characteristics developed earlier for each building type and simulated the impact of HIR strategies on building cooling- and heating-energy use and peak power demand using the DOE-2.1E model. Our simulations included the impact of (1) strategically-placed shade trees near buildings [direct effect], (2) use of high-albedo roofing material on the building [direct effect], (3) urban reforestation with high-albedo pavements and building surfaces [indirect effect] and (4) combined strategies 1, 2, and 3 [direct and indirect effects]. We then estimated the total roof area of air

  9. A low-power multi port register file design using a low-swing strategy

    International Nuclear Information System (INIS)

    Yan Hao; Liu Yan; Hua Siliang; Wang Donghui; Hou Chaohuan

    2012-01-01

    A low-power register file is designed by using a low-swing strategy and modified NAND address decoders. The proposed low-swing strategy is based on the feedback scheme and uses dynamic logic to reduce the active feedback power. This method contains two parts: WRITE and READ strategy. In the WRITE low-swing scheme, the modified memory cell is used to support low-swing WRITE. The modified NAND decoder not only dissipates less power, but also enables a great deal of area reduction. Compared with the conventional single-ended register file, the low-swing strategy saves 34.5% and 51.15% bit-line power in WRITE and READ separately. The post simulation results indicate a 39.4% power improvement when the twelve ports are all busy. (semiconductor integrated circuits)

  10. Evaluation of Different Power Saving Techniques for MBMS Services

    Directory of Open Access Journals (Sweden)

    Antonios Alexiou

    2009-01-01

    Full Text Available Over the last years we have witnessed an explosive growth of multimedia computing, wireless communication and applications. Following the rapid increase in penetration rate of broadband services, the Third Generation Partnership Project (3GPP is currently standardizing the Evolved-Multimedia Broadcast/Multicast Service (E-MBMS framework of Long Term Evolution (LTE, the successor of Universal Mobile Telecommunications System (UMTS. MBMS constitutes a point-to-multipoint downlink bearer service that was designed to significantly decrease the required radio and wired link resources. However, several obstacles regarding the high-power requirements should be overcome for the realization of MBMS. Techniques, such as Macrodiversity Combining and Rate Splitting, could be utilized to reduce the power requirement of delivering multicast traffic to MBMS users. In this paper, we analytically present several power saving techniques and analyze their performance in terms of power consumption. We provide simulation results that reveal the amount of power that is saved and reinforce the need for the usage of such techniques.

  11. Variable flow controls of closed system pumps for energy savings in maritime power systems

    OpenAIRE

    Su, Chun-Lien; Liao, Chi-Hsiang; Chou, Tso-Chu; Chou, Ming-Hung; Guerrero, Josep M.

    2016-01-01

    Pumps are extensively used in maritime industries as marine vessels utilize a wide range of pumps and pumping techniques to transfer and distribute all types of air and fluids. The electrical energy consumed by the various motors accounts for about 70% of a vessel’s total power consumption, and this presents a problem in unique marine environments. Such situations are especially conducive to energy-saving strategies using variable frequency drives (VFDs) in centrifugal load service. This pape...

  12. AutoPowerOff plug banks - a story with energy saving perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Hjort Jensen, Anders (The Danish Electricity Saving Trust (Denmark)); Fjordbak, Troels (IT Energy ApS (Denmark))

    2009-07-01

    Denmark uses around 35 TWh of electricity per year, with residential dwellings accounting for around 10 TWh of this figure. Standby consumption comprises around 12% of power used in homes. If every Danish home installed AutoPowerOff plug banks, savings exceeding 500 GWh per year would be possible, equivalent to 5% of household electricity consumption, or 1.5% of the total in Denmark. This paper describes the estimated standby consumption in Danish homes in 2006, and possible energy savings through the use of AutoPowerOff plug banks. The estimates were subsequently used as background information for a 2007-2008 campaign to promote the wider use of these devices in Denmark. In order to increase the sale of AutoPowerOff plug banks by 1 million units, it was agreed that retail chains selling consumer electronics would include an AutoPowerOff when selling a TV or PC. A nationwide TV advertising campaign was launched featuring the names of participating retailers. Sales of AutoPowerOff plug banks in the first 7 months of 2008 passed the 515,000 mark, with over 1 million units now installed in 2.5 million Danish households. Annual savings are estimated to be over 80 GWh, equivalent to 40,000 tons of CO{sub 2}. This equates to potential savings on an EU-wide basis of more than 7 TWh, or 3.6 million tons of CO{sub 2} in Denmark.

  13. Relationship between people's awareness of environmental capabilities of saving energy, photovoltaic power generation and nuclear power generation

    International Nuclear Information System (INIS)

    Hashiba, Takashi

    2001-01-01

    In this research, relationship between people's awareness of environmental capabilities of saving energy, photovoltaic power generation (PV) and nuclear power generation was investigated using questionnaire method. The results showed that saving energy is conducted without reference to its environment preservation effect. However the older people tend to regard saving energy as contribution to environment preservation. The attitude toward usage of PV has a close relationship to awareness of energy environmental concerns. Acceptance of cost sharing for the introducing of wide-scale PV systems to society is related to environment protection image of PV and the attitude toward loss of social convenience lost as a result of saving energy activities. The older people become, the more priority people put on environment protection before the social convenience. There is little relationship between environmental capabilities of nuclear power generation, that never discharge CO 2 on generation, and awareness of energy environmental concerns. (author)

  14. Environmental benefit analysis of strategies for potable water savings in residential buildings.

    Science.gov (United States)

    Marinoski, Ana Kelly; Rupp, Ricardo Forgiarini; Ghisi, Enedir

    2018-01-15

    The objective of this study is to assess the environmental benefit of using rainwater, greywater, water-efficient appliances and their combinations in low-income houses. The study was conducted surveying twenty households located in southern Brazil, which resulted in water end-uses estimation. Then, embodied energy, potential for potable water savings and sewage reduction when using the different strategies were estimated. The environmental benefit analysis of these strategies was performed using an indicator that includes embodied energy, potable water savings, reduction of sewage and energy consumption in the water utility, and sewage production during the life cycle of the system. The results indicated that the strategy with the greatest environmental benefit is the use of water-efficient appliances, which resulted in substantial water savings and reduction of sewage, causing low environmental impact due to lower embodied energy over the life cycle. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Energy savings in dynamic and resilient optical networks based on traffic-aware strategies

    DEFF Research Database (Denmark)

    Turus, Ioan; Fagertun, Anna Manolova; Dittmann, Lars

    2014-01-01

    andconnections. Results show that symbol-rateadaptation provides high savings for unprotected scenarios (37% energy savings w.r.t. unprotected Baseline), while for theprotected scenarios better results are obtained for modulationformat adaptation which includes sleep-mode (57.1% energysavings w.r.t. protected...... Baseline). Moreover, compared to theBaseline scenarios the Mixed adaptation, combining bothsymbol-rate and modulation format, is the most power-efficientstrategy providing 39% energy savings for unprotected scenarioand 70% energy savings for dedicated protection scenario.......An analysis of the energy savingsis presentedwhen taking into account a complete traffic model for a one-yeartime period. Daily and weekly traffic fluctuations as well asyearly traffic growth are considered whenanalyzing the powerconsumption.Low power mode in optoelectronic devices (sleep...

  16. Save energy - for industry

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    The article is an interview with Glenn Bjorklund, Vice President of SCalEd (Southern California Edison). The variations in Californian power demand and public electricity consumption habits are explained, together with types of power source used in electricity production. Questions are posed concerning SCalEd's energy saving strategy. The political implications of electricity charge changes are discussed. The planned energy resources for 1982-1992 are given with nuclear power being the largest contributor. (H.J.P./G.T.H.)

  17. Variable flow controls of closed system pumps for energy savings in maritime power systems

    DEFF Research Database (Denmark)

    Su, Chun-Lien; Liao, Chi-Hsiang; Chou, Tso-Chu

    2016-01-01

    and field tests of a practical auxiliary boiler feed water management system on a commercial vessel. It is proved that the proposed method can maintain constant water pressure for closed system pumps and provide an efficient way to measure energy savings and maintenance benefits. The results serve......Pumps are extensively used in maritime industries as marine vessels utilize a wide range of pumps and pumping techniques to transfer and distribute all types of air and fluids. The electrical energy consumed by the various motors accounts for about 70% of a vessel’s total power consumption......, and this presents a problem in unique marine environments. Such situations are especially conducive to energy-saving strategies using variable frequency drives (VFDs) in centrifugal load service. This paper presents the design and results of applying variable frequency constant pressure technology in closed system...

  18. Traffic-aware Elastic Optical Networks to leverage Energy Savings

    DEFF Research Database (Denmark)

    Turus, Ioan; Fagertun, Anna Manolova; Dittmann, Lars

    2014-01-01

    Because of the static nature of the deployed optical networks, large energy wastage is experienced today in production networks such as Telecom networks . With power-adaptive optical interfaces and suitable grooming procedures, we propose the design of more energy efficient transport networks....... Optical network reconfigurations are performed by GMPLS node controllers according to monitored traffic information. The investigated energy reduction strategies are simulated on two large scale transport networks (DT17 and COST37). The results show that the energy savings obtained by these strategies......-Europea n COST37 network, for both symbol-rate and modulation format adaptations significant savings are obtained . Mixed adaptation (jointly performing symbol-rate and modulation format adaptations) used together with optical grooming allows up to 4 4 % and 4 7 % power savings in DT17 and COST37 networks...

  19. Energy-saving decomposition and power consumption forecast: The case of liaoning province in China

    Energy Technology Data Exchange (ETDEWEB)

    He, Y.X.; Zhao, Y.S.; Wang, Y.J. [School of Business Administration, North China Electric Power University, Zhu Xin Zhuang, Bei Nong Lu No. 2, Changping District, Beijing (China); Zhang, S.L. [Finance Department, Nanning Power Supply Bureau, Xingguang Street No. 43, Nanning, Guangxi Autonomous Region (China); Li, F.R. [University of Bath, Bath, BA2 7AY (United Kingdom)

    2011-01-15

    To achieve sustainable development of the society, the People's Republic of China (PRC) proposed in its 11th Five-Year Plan for National Economic and Social Development Program a shift in energy-saving target of decreasing energy intensity by 20% in 2010 compared with that of 2005. Liaoning province is one of the oldest industrial bases in China. Policymakers are often confronted with problems relating to adjustment in the development pattern as a means to secure steady economic growth. The power industry is a fundamental energy industry; it plays an important role in realizing of energy-saving targets. Based on the input-output model, this paper sets extensive, planning and 20% energy-saving scenarios in order to analyze energy-saving and power consumption situations for Liaoning by 2010. Through extensive simulations, the levels of energy-saving and power demand under different scenarios are obtained. Results from the analysis show that under the premises of adjusting the ratio of investment and consumption, optimizing products structure, and improving energy use efficiency, it is possible to achieve the proposed energy-saving target. Liaoning's power consumption can maintain a stable growth trend in the future. The percentage of electricity to the total energy use can also increase to 16% in 2010. (author)

  20. Energy-saving strategies with personalized ventilation in cold climates

    DEFF Research Database (Denmark)

    Shiavon, Stefano; Melikov, Arsen Krikor

    2009-01-01

    In this study the influence of the personalized supply air temperature control strategy on energy consumption and the energy-saving potentials of a personalized ventilation system have been investigated by means of simulations with IDA-ICE software. GenOpt software was used to determine the optimal...

  1. Relationship between people's awareness of environmental capabilities of saving energy, photovoltaic power generation and nuclear power generation

    Energy Technology Data Exchange (ETDEWEB)

    Hashiba, Takashi [Institute of Nuclear Safety System Inc., Mihama, Fukui (Japan)

    2001-09-01

    In this research, relationship between people's awareness of environmental capabilities of saving energy, photovoltaic power generation (PV) and nuclear power generation was investigated using questionnaire method. The results showed that saving energy is conducted without reference to its environment preservation effect. However the older people tend to regard saving energy as contribution to environment preservation. The attitude toward usage of PV has a close relationship to awareness of energy environmental concerns. Acceptance of cost sharing for the introducing of wide-scale PV systems to society is related to environment protection image of PV and the attitude toward loss of social convenience lost as a result of saving energy activities. The older people become, the more priority people put on environment protection before the social convenience. There is little relationship between environmental capabilities of nuclear power generation, that never discharge CO{sub 2} on generation, and awareness of energy environmental concerns. (author)

  2. The impact of translucent fabric shades and control strategies on energy savings and visual quality

    Science.gov (United States)

    Wankanapon, Pimonmart

    Translucent fabric shades provide opportunities for building occupants to control sunlight penetration for heat reduction, thermal comfort, and visual quality. Regulating shades affects building energy and can potentially reduce the size of mechanical cooling systems. Shades are not normally included in energy model studies during the design process, even though shades potential impact energy use. This is because the occupants normally leave shades closed a large fraction of the time, but models are generally performed with no shades. Automatic shade control is now available, so it is necessary to understand the impact of shades on visual quality and their energy saving potential in order to optimize their overall performance. There are very limited studies that have address shades and their integrated performance on energy consumption and visual quality. Most of these do not reflected modern shade types and their application. The goals of this study are: First, to determine the impact of shades on total, heating, cooling and lighting energy savings with different design and operation parameters. Second, to study and develop different automatic shade control strategies to promote and optimize energy savings and visual quality. A simulation-based approach using EnergyPlus in a parametric study provide better understanding energy savings under different shade conditions. The parametric runs addressed various building parameters such as geometry, orientation, site climate, glazing/shade properties, and shade control strategies with integrated lighting control. The impact of shades was determined for total building and space heating, cooling and lighting energy savings. The effect of shades on visual quality was studied using EnergyPlus, AGI32 and DAYSIM for several indices such as daylight glare index (DGI), work plane illuminance, luminance ratios and view. Different shade control strategies and integrated lighting control were considered with two translucent fabric

  3. A review on the long-range strategy of nuclear power development

    International Nuclear Information System (INIS)

    An, Shigehiro; Kondo, Shunsuke; Ishida, Hiroshi.

    1979-01-01

    Nuclear power generation in Japan is proceeding steadily, such as the world's second in power generating capacity and the nation's own development of power reactors. Meanwhile, however, there are number of problems for future solution, like the establishment of nuclear fuel cycle, before nuclear energy is fully harnessed. Looking as far ahead as the 21st century, the long-range strategy of nuclear power development is reviewed: politics on uranium supply outlook, a compromise between uranium enrichment and nuclear nonproliferation, LWR technology with safety, FBR development scheme, uranium resources saving and heavy water reactor, HTGR development, a 2nd fuel reprocessing plant, high level wastes management, reactors decommissioning, research in nuclear energy development, and fostering of a nuclear power industry. (J.P.N.)

  4. Research on Energy-Saving Operation Strategy for Multiple Trains on the Urban Subway Line

    Directory of Open Access Journals (Sweden)

    Jianqiang Liu

    2017-12-01

    Full Text Available Energy consumption for multiple trains on the urban subway line is predominantly affected by the operation strategy. This paper proposed an energy-saving operation strategy for multiple trains, which is suitable for various line conditions and complex train schedules. The model and operation modes of the strategy are illustrated in detail, aiming to take full use of regenerative braking energy in complex multi-train systems with different departure intervals and dwell times. The computing method is proposed by means of the heuristic algorithm to obtain the optimum operation curve for each train. The simulation result based on a real urban subway line is provided to verify the correctness and effectiveness of the proposed energy-saving operation strategy.

  5. Saving more to consume more. EDF's communication ambiguities during the energy saving era

    International Nuclear Information System (INIS)

    Bouvier, Yves

    2012-01-01

    Since 1974, EDF is placed between a communication scheme imposed for energy savings and an industrial strategy of massive investment in nuclear power. In ten years, the company managed to increase households electricity consumption without advertising, due in particular to electric heating. But strong tensions were generated by this situation and led the company to develop an institutional communication to the employees and to the general public

  6. Novel power saving architecture for FBG based OCDMA code generation

    Science.gov (United States)

    Osadola, Tolulope B.; Idris, Siti K.; Glesk, Ivan

    2013-10-01

    A novel architecture for generating incoherent, 2-dimensional wavelength hopping-time spreading optical CDMA codes is presented. The architecture is designed to facilitate the reuse of optical source signal that is unused after an OCDMA code has been generated using fiber Bragg grating based encoders. Effective utilization of available optical power is therefore achieved by cascading several OCDMA encoders thereby enabling 3dB savings in optical power.

  7. The Energy Saving Potential of Occupancy-Based Lighting Control Strategies in Open-Plan Offices: The Influence of Occupancy Patterns

    Directory of Open Access Journals (Sweden)

    Christel de Bakker

    2017-12-01

    Full Text Available Occupancy-based lighting control strategies have been proven to be effective in diminishing offices’ energy consumption. These strategies have typically worked by controlling lighting at the room level but, recently, lighting systems have begun to be equipped with sensors on a more fine-grained level, enabling lighting control at the desk level. For some office cases, however, the savings gained using this strategy may not outweigh the costs and design efforts compared to room control. This is because, in some offices, individual occupancy patterns are similar, hence the difference in savings between desk and room control would be minimal. This study examined the influence of occupancy pattern variance within an office space on the relative energy savings of control strategies with different control zone sizes. We applied stochastic modeling to estimate the occupancy patterns, as this method can account for uncertainty. To validate our model, simulation results were compared to earlier studies and real measurements, which demonstrated that our simulations provided realistic occupancy patterns. Next, office cases varying in both job-function type distribution and office policy were investigated on energy savings potential to determine the influence of occupancy pattern variance. The relative energy savings potential of the different control strategies differed minimally for the test cases, suggesting that variations in individual occupancy patterns negligibly influence energy savings. In all cases, lighting control at the desk level showed a significantly higher energy savings potential than strategies with lower control zone granularity, suggesting that it is useful to implement occupancy-based lighting at the desk level in all office cases. This strategy should, thus, receive more attention from both researchers and lighting designers.

  8. Vattenfall want to save money: will run Ringhals 3 and 4 with reduced power

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    Ringhals 3 and 4 are nuclear power stations which require re-design before full power can be generated. To save money both stations will be running at reduced power during 1982 to generate power and gain running experience. (J.H.)

  9. Saving assessment using the PERS in solar power towers

    International Nuclear Information System (INIS)

    Rodriguez-Sanchez, M.R.; Sanchez-Gonzalez, A.; Marugan-Cruz, C.; Santana, D.

    2014-01-01

    Highlights: • The lamination of the solar salt is avoided using the PERS and the main energy sink. • The PERS using salt pump as turbine saves 30–50% of the parasitic power. • The most appropriate configuration is a similar turbine three times one salt pump. • The payback period is around two years, and the economical savings from 1 to 4 M$. - Abstract: The improvement of the solar power tower using solar salt is one of the main goals of researchers. Any method or invention to improve the efficiency of this technology contributes to promote the renewable energies. The use of a Potential Energy Recovery System (PERS) in two different solar power tower plants of 20 and 100 MW has been analysed. The PERS is formed, at least, by one turbine, located at the hot salt pipe coming from the receiver. The turbine is engaged to the shaft of the feed pump, which raises the heat transfer fluid from the cold tank to the receiver. It reduces the parasitic power consumption of the plant, and increases its global efficiency. Different PERS configurations have been modelled. Based on an energetic and economic analysis, the optimal configuration is a geometrical similar turbine of three times the volume flow rate of one feed pump. The PERS has been proven to be a cost reductive and clean tool. For a 100 MW power plant of 30-year lifetime the investment cost is 1.26 M$ and the annual cash flow is 0.89 M$, while for a plant of 20 MW these values are 0.26 M$ and 0.19 M$, respectively

  10. Power Subscription Strategy

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    1998-12-21

    This document lays out the Bonneville Power Administration`s Power Subscription Strategy, a process that will enable the people of the Pacific Northwest to share the benefits of the Federal Columbia river Power System after 2001 while retaining those benefits within the region for future generations. The strategy also addresses how those who receive the benefits of the region`s low-cost federal power should share a corresponding measure of the risks. This strategy seeks to implement the subscription concept created by the Comprehensive Review in 1996 through contracts for the sale of power and the distribution of federal power benefits in the deregulated wholesale electricity market. The success of the subscription process is fundamental to BPA`s overall business purpose to provide public benefits to the Northwest through commercially successful businesses.

  11. Offshore wind energy storage concept for cost-of-rated-power savings

    International Nuclear Information System (INIS)

    Qin, Chao; Saunders, Gordon; Loth, Eric

    2017-01-01

    Highlights: •Investigated CAES + HPT system concept for offshore wind energy; •Validated cost model for offshore wind farm including CAPEX and OPEX items; •Quantified cost-of-rated-power savings associated with CAES + HPT concept; •Estimated savings of 21.6% with CAES + HPT for a sample $2.92 billion project. -- Abstract: The size and number of off-shore wind turbines over the next decade is expected to rapidly increase due to the high wind energy potential and the ability of such farms to provide utility-scale energy. In this future, inexpensive and efficient on-site wind energy storage can be critical to address short-time (hourly) mismatches between wind supply and energy demand. This study investigates a compressed air energy storage (CAES) and hydraulic power transmission (HPT) system concept. To assess cost impact, the NREL Cost and Scaling Model was modified to improve accuracy and robustness for offshore wind farms with large turbines. Special attention was paid to the support structure, installation, electrical interface and connections, land leasing, and operations and maintenance cost items as well as specific increased/reduced costs reductions associated with CAES + HPT systems. This cost model was validated and applied to a sample $2.92 billion project Virginia Offshore case It was found that adaption of CAES + HPT can lead to a substantial savings of 21.6% of this 20-year lifetime cost by dramatically reducing capital and operating cost of the generator and power transmission components. However, there are several additional variables that can impact the off-shore energy policy and planning for this new CAES + HPT concept. Furthermore, these cost-savings are only first-order estimates based on linear mass-cost relationships, and thus detailed engineering and economic analysis are recommended.

  12. Electricity consumption and electricity saving in the Swedish households

    Energy Technology Data Exchange (ETDEWEB)

    Bernstroem, B M; Eklund, Y; Sjoeberg, L

    1997-03-01

    The objective of the present study is to determine which factors influence electricity consumption behavior of Swedish households, the level of knowledge about electricity use and the willingness to pay for the use of electricity. In Sweden, as in many other developed countries, the need for electric power is constantly increasing. The major reason for this increase in electricity consumption is the lifestyle of a modern society. A feature in the nuclear power discussion is that the government in Sweden is having a hard time to establish how to phase-out all nuclear power plants by 2010. An additional major change in Swedish energy policy is the deregulation of the electricity market, which started in the beginning of 1996. There is an increased demand for strategies to save electricity among households. The results of this study stress the difficulties in reducing electricity consumption and to develop new electricity saving strategies in Sweden 125 refs, 6 figs, 21 tabs

  13. Maximum power point tracking: a cost saving necessity in solar energy systems

    Energy Technology Data Exchange (ETDEWEB)

    Enslin, J H.R. [Stellenbosch Univ. (South Africa). Dept. of Electrical and Electronic Engineering

    1992-12-01

    A well engineered renewable remote energy system, utilizing the principal of Maximum Power Point Tracking (MPPT) can improve cost effectiveness, has a higher reliability and can improve the quality of life in remote areas. A high-efficient power electronic converter, for converting the output voltage of a solar panel, or wind generator, to the required DC battery bus voltage has been realized. The converter is controlled to track the maximum power point of the input source under varying input and output parameters. Maximum power point tracking for relative small systems is achieved by maximization of the output current in a battery charging regulator, using an optimized hill-climbing, inexpensive microprocessor based algorithm. Through practical field measurements it is shown that a minimum input source saving of between 15 and 25% on 3-5 kWh/day systems can easily be achieved. A total cost saving of at least 10-15% on the capital cost of these systems are achievable for relative small rating Remote Area Power Supply (RAPS) systems. The advantages at large temperature variations and high power rated systems are much higher. Other advantages include optimal sizing and system monitor and control. (author).

  14. Intelligent control of energy-saving power generation system

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Zhiyuan; Zhang, Guoqing; Guo, Zhizhong [Harbin Institute of Technology, Harbin (China). Dept. of Electrical Engineering

    2013-07-01

    Highway power generation system which is environmentally friendly and sustainable provides an innovative method of energy conversion. It is also as a kind of city science and technology innovation, which has the characteristics of environmental protection and sustainable utilization. Making full use of vehicle impact speed control humps, we design a new kind of highway speed control humps combined with solar electric generation system integration. Developing green energy, energy saving and environment protection can be achieved.

  15. Energy-saving control strategy for lighting system based on multivariate extremum seeking with Newton algorithm

    International Nuclear Information System (INIS)

    Yin, Chun; Dadras, Sara; Huang, Xuegang; Mei, Jun; Malek, Hadi; Cheng, Yuhua

    2017-01-01

    Highlights: • An energy-saving control strategy is proposed for multi-group lighting sources. • The proposed controller is designed to minimize the light-energy consumption. • It is designed to speed up the convergence rate without increasing the oscillation. • The minimal energy usage is guaranteed, while keeping the desired lighting level. • Experimental results shows the superiorities of the energy-saving control strategy. - Abstract: In recent years, the energy problem has been a universal concern. In order to improve the lighting energy efficiency and reduce the electric energy consumption, this paper develops an energy-saving control strategy for the lighting system with multiple lighting sources. The control strategy presented in this paper includes two parts: a new multivariate extremum seeking control method with Newton algorithm is developed to minimize the light-energy consumption by separately manipulating the brightness of multiple lighting sources, and a proportion-integration-differentiation control approach is adopted to realize the desired lighting level. The proposed scheme can increase the convergence speed of the closed loop system toward the minimum light-energy consumption, meanwhile, the accuracy of the control strategy will be improved. Experimental results illustrate that the light-energy consumption via the proposed method can reach more rapidly to a smaller vicinity of the minimum energy point, so, the lighting energy efficiency is greatly increased accordingly.

  16. ONU power saving modes in next generation optical access networks: progress, efficiency and challenges.

    Science.gov (United States)

    Dixit, Abhishek; Lannoo, Bart; Colle, Didier; Pickavet, Mario; Demeester, Piet

    2012-12-10

    The optical network unit (ONU), installed at a customer's premises, accounts for about 60% of power in current fiber-to-the-home (FTTH) networks. We propose a power consumption model for the ONU and evaluate the ONU power consumption in various next generation optical access (NGOA) architectures. Further, we study the impact of the power savings of the ONU in various low power modes such as power shedding, doze and sleep.

  17. Strategy on energy saving reconstruction of distribution networks based on life cycle cost

    Science.gov (United States)

    Chen, Xiaofei; Qiu, Zejing; Xu, Zhaoyang; Xiao, Chupeng

    2017-08-01

    Because the actual distribution network reconstruction project funds are often limited, the cost-benefit model and the decision-making method are crucial for distribution network energy saving reconstruction project. From the perspective of life cycle cost (LCC), firstly the research life cycle is determined for the energy saving reconstruction of distribution networks with multi-devices. Then, a new life cycle cost-benefit model for energy-saving reconstruction of distribution network is developed, in which the modification schemes include distribution transformers replacement, lines replacement and reactive power compensation. In the operation loss cost and maintenance cost area, the operation cost model considering the influence of load season characteristics and the maintenance cost segmental model of transformers are proposed. Finally, aiming at the highest energy saving profit per LCC, a decision-making method is developed while considering financial and technical constraints as well. The model and method are applied to a real distribution network reconstruction, and the results prove that the model and method are effective.

  18. Use a renewable energy sources and latest power-saving technologies in the the Republic Kazakstan

    International Nuclear Information System (INIS)

    Gulevich, N.V.

    1996-01-01

    The subject of alternative power in Kazakstan is brought up. Wind-, hydro-, solar power, biogas installation can improve the Republic power base. The main directions of activity of A. Einstein International Power engineering Academy on involving renewable energy sources and latest power-saving technologies to Republic of Kazakstan's fuel-power balance is given. It should be noted that renewable power engineering usually handles reversible energy sources and reserved power cycles. (author)

  19. Energy saved neon sign lighting power supply for photovoltaic systems

    Energy Technology Data Exchange (ETDEWEB)

    Tanitteerapan, T.; Dokpikul, S.; Arunrungrasmi, S. [King Mongkut Univ. of Technology Thonburi, Bangmod, Tungkru, Bangkok (Thailand). Dept. of Electrical Technology Education, Faculty of Industrial Education

    2007-07-01

    Petroleum oil, natural gas and fossil fuels are commonly used in power plants for electrical power generation. However, because of their negative environmental impacts, energy and environmental savings from renewable energy resources are necessary choices. Solar energy can be converted to the electrical voltage by using solar arrays. This process can be used in many electrical applications. This paper introduced a neon sign lighting power supply for a small photovoltaic powered stand-alone commercial advertising board for a remote area in Thailand. The circuit implementation was very simple, consisting of an active switch device, a resonant capacitor and high frequency transformer. The control also operated as a fixed frequency and fixed duty ratio controller. The paper discussed the principle of neon sign lighting, power circuit operation, and control circuit operation. To verify the proposed power supply, the circuit experiment of the proposed power supply for the neon sign lighting was applied to a 10 foot long, 10 millimeter diameter bulb. The neon sign was ignited smoothly with little power consumption. 2 refs., 1 tab., 10 figs.

  20. Low power offloading strategy for femto-cloud mobile network

    Directory of Open Access Journals (Sweden)

    Anwesha Mukherjee

    2016-03-01

    Full Text Available Nowadays offloading is a popular method of mobile cloud computing where the required computation takes place remotely inside the cloud. But whether to process an application inside the mobile device or to the cloud is a challenging issue because communication with the cloud involves latency and power consumption. This paper has proposed a method of decision making regarding whether to offload or not-to-offload an application to the cloud. According to the proposed strategy, application is offloaded only if it results in lower power consumption than local execution within the mobile device itself. If this condition is satisfied, computation time and deadline of the job are considered as the basic parameters to decide whether to offload or not. Experimental results demonstrate that the proposed offloading algorithm reduces the power consumption to approximately 3–32%. To achieve power-efficiency and security both, femto-cloud architecture is used in the proposed work. In this case offloading from the mobile device to the cloud takes place through the low power and secure femtocell base station. Simulation results present that using femto-cloud architecture 70–83% and 52–66% power savings are achieved than using macrocell and microcell base stations respectively while offloading an application to the cloud.

  1. Power Flow Distribution Strategy for Improved Power Electronics Energy Efficiency in Battery Storage Systems: Development and Implementation in a Utility-Scale System

    Directory of Open Access Journals (Sweden)

    Michael Schimpe

    2018-03-01

    Full Text Available Utility-scale battery storage systems typically consist of multiple smaller units contributing to the overall power dispatch of the system. Herein, the power distribution among these units is analyzed and optimized to operate the system with increased energy efficiency. To improve the real-life storage operation, a holistic system model for battery storage systems has been developed that enables a calculation of the energy efficiency. A utility-scale Second-Life battery storage system with a capacity of 3.3 MWh/3 MW is operated and evaluated in this work. The system is in operation for the provision of primary control reserve in combination with intraday trading for controlling the battery state of charge. The simulation model is parameterized with the system data. Results show that losses in power electronics dominate. An operational strategy improving the energy efficiency through an optimized power flow distribution within the storage system is developed. The power flow distribution strategy is based on the reduction of the power electronics losses at no-load/partial-load by minimizing their in-operation time. The simulation derived power flow distribution strategy is implemented in the real-life storage system. Field-test measurements and analysis prove the functionality of the power flow distribution strategy and reveal the reduction of the energy throughput of the units by 7%, as well as a significant reduction of energy losses in the units by 24%. The cost savings for electricity over the system’s lifetime are approximated to 4.4% of its investment cost.

  2. Marginal costs of water savings from cooling system retrofits: a case study for Texas power plants

    Science.gov (United States)

    Loew, Aviva; Jaramillo, Paulina; Zhai, Haibo

    2016-10-01

    The water demands of power plant cooling systems may strain water supply and make power generation vulnerable to water scarcity. Cooling systems range in their rates of water use, capital investment, and annual costs. Using Texas as a case study, we examined the cost of retrofitting existing coal and natural gas combined-cycle (NGCC) power plants with alternative cooling systems, either wet recirculating towers or air-cooled condensers for dry cooling. We applied a power plant assessment tool to model existing power plants in terms of their key plant attributes and site-specific meteorological conditions and then estimated operation characteristics of retrofitted plants and retrofit costs. We determined the anticipated annual reductions in water withdrawals and the cost-per-gallon of water saved by retrofits in both deterministic and probabilistic forms. The results demonstrate that replacing once-through cooling at coal-fired power plants with wet recirculating towers has the lowest cost per reduced water withdrawals, on average. The average marginal cost of water withdrawal savings for dry-cooling retrofits at coal-fired plants is approximately 0.68 cents per gallon, while the marginal recirculating retrofit cost is 0.008 cents per gallon. For NGCC plants, the average marginal costs of water withdrawal savings for dry-cooling and recirculating towers are 1.78 and 0.037 cents per gallon, respectively.

  3. Energy Saving Performance Analysis of An Inverter-based Regenerative Power Re-utilization Device for Urban Rail Transit

    Science.gov (United States)

    Li, Jin; Qiu, Zhiling; Hu, Leilei

    2018-04-01

    The inverter-based regenerative braking power utilization devices can re-utilize the regenerative energy, thus reduce the energy consumption of urban rail transit. In this paper the power absorption principle of the inverter-based device is introduced, then the key influencing factors of energy saving performance are analyzed based on the absorption model. The field operation data verified that the control DC voltage plays an important role and lower control DC voltage yields more energy saving. Also, the one year energy saving performance data of an inverter-based re-utilization device located in NanJing S8 line is provided, and more than 1.2 million kWh energy is recovered in the one year operation.

  4. How EPRI [Electric Power Research Institute] helps utilities save money

    International Nuclear Information System (INIS)

    Anon.

    1996-01-01

    A number of case studies are presented which illustrate how the work of the Electric Power Research Institute in the USA has enabled nuclear utilities to save money. The areas covered by the examples are: steam generator tube repair; streamlining of reliability centred maintenance; cost effective instrumentation and control maintenance; reducing the frequency of instrument calibration; optimising the engineering change process; detecting and reducing fuel failure; extending the qualified life of equipment. (U.K.)

  5. Investigation on the Factors Affecting the Temperature in Urban Distribution Substations and an Energy-Saving Cooling Strategy

    Directory of Open Access Journals (Sweden)

    Fan Yang

    2011-02-01

    Full Text Available The different locations of the equipment in urban distribution substations (DSSs and the location of inlet holes and outlet holes usually result in different ventilation effect, which means the power consumed by any ventilating devices present is different. In this paper the temperature field distribution in an urban distribution substation with different locations of the equipment in the substation was calculated first, then factors influencing the temperature field distribution were investigated, and the influence of the different factors was analyzed. When the distance between the apparatus and walls exceeds 3 m, the change of the temperature in the DSS is very small. Therefore considering the floor area of the DSS, 3 m is the best value of the distance between the apparatus. With the change of the environment temperature or the velocity of the ventilation fans, the maximum temperature in the DSS or apparatus will change. Hence an energy saving ventilation strategy is proposed in the paper, and an intelligent cooling control system is developed, which can modify the velocity of the ventilation fans according to the environment temperature, and thus realize energy savings.

  6. PEMFC Optimization Strategy with Auxiliary Power Source in Fuel Cell Hybrid Vehicle

    Directory of Open Access Journals (Sweden)

    Tinton Dwi Atmaja

    2012-02-01

    Full Text Available Page HeaderOpen Journal SystemsJournal HelpUser You are logged in as...aulia My Journals My Profile Log Out Log Out as UserNotifications View (27 new ManageJournal Content SearchBrowse By Issue By Author By Title Other JournalsFont SizeMake font size smaller Make font size default Make font size largerInformation For Readers For Authors For LibrariansKeywords CBPNN Displacement FLC LQG/LTR Mixed PMA Ventilation bottom shear stress direct multiple shooting effective fuzzy logic geoelectrical method hourly irregular wave missile trajectory panoramic image predator-prey systems seawater intrusion segmentation structure development pattern terminal bunt manoeuvre Home About User Home Search Current Archives ##Editorial Board##Home > Vol 23, No 1 (2012 > AtmajaPEMFC Optimization Strategy with Auxiliary Power Source in Fuel Cell Hybrid VehicleTinton Dwi Atmaja, Amin AminAbstractone of the present-day implementation of fuel cell is acting as main power source in Fuel Cell Hybrid Vehicle (FCHV. This paper proposes some strategies to optimize the performance of Polymer Electrolyte Membrane Fuel Cell (PEMFC implanted with auxiliary power source to construct a proper FCHV hybridization. The strategies consist of the most updated optimization method determined from three point of view i.e. Energy Storage System (ESS, hybridization topology and control system analysis. The goal of these strategies is to achieve an optimum hybridization with long lifetime, low cost, high efficiency, and hydrogen consumption rate improvement. The energy storage system strategy considers battery, supercapacitor, and high-speed flywheel as the most promising alternative auxiliary power source. The hybridization topology strategy analyzes the using of multiple storage devices injected with electronic components to bear a higher fuel economy and cost saving. The control system strategy employs nonlinear control system to optimize the ripple factor of the voltage and the current

  7. Social Optimization and Pricing Policy in Cognitive Radio Networks with an Energy Saving Strategy

    Directory of Open Access Journals (Sweden)

    Shunfu Jin

    2016-01-01

    Full Text Available The rapid growth of wireless application results in an increase in demand for spectrum resource and communication energy. In this paper, we firstly introduce a novel energy saving strategy in cognitive radio networks (CRNs and then propose an appropriate pricing policy for secondary user (SU packets. We analyze the behavior of data packets in a discrete-time single-server priority queue under multiple-vacation discipline. With the help of a Quasi-Birth-Death (QBD process model, we obtain the joint distribution for the number of SU packets and the state of base station (BS via the Matrix-Geometric Solution method. We assess the average latency of SU packets and the energy saving ratio of system. According to a natural reward-cost structure, we study the individually optimal behavior and the socially optimal behavior of the energy saving strategy and use an optimization algorithm based on standard particle swarm optimization (SPSO method to search the socially optimal arrival rate of SU packets. By comparing the individually optimal behavior and the socially optimal behavior, we impose an appropriate admission fee to SU packets. Finally, we present numerical results to show the impacts of system parameters on the system performance and the pricing policy.

  8. Saving electricity in a hurry. Dealing with temporary shortfalls in electricity supplies

    Energy Technology Data Exchange (ETDEWEB)

    none

    2005-07-01

    Blackouts are normally the result of imbalances in electricity supply and demand. A brief blackout is mostly an inconvenience. But persistent shortfalls ? those lasting days, weeks, or months ? can cause economic disruption and danger to human life in our technology-rich societies. Saving Electricity in a Hurry describes some of the recent power shortfalls, from Norway to New Zealand, from Tokyo to Arizona and the policies these regions used to quickly reduce their power consumption. How did the whole country of Sweden cut its power consumption by 4% in only three days? How did California save 14% in only a few months? While the temporary shortfalls in electricity supplies described in this book are relatively rare events, they disproportionately shape future energy policies. Saving Electricity in a Hurry shows that countries can quickly reduce electricity consumption without harming the economy as much as blackouts or unplanned curtailments. The strategies are diverse, unique and often surprisingly cheap. They include mass media campaigns ? where a good joke can save a Megawatt ? improvements in equipment efficiency and quickly adjusting electricity prices. This book explains how California replaced a million traffic signals with energy-saving models, how millions of Tokyo residents raised their thermostat settings, and how New Zealanders took shorter showers, all quickly enough to help avoid imminent blackouts. Finally, it connects these policies to the traditional goal of ?saving electricity slowly?.

  9. Heat savings in buildings in a 100% renewable heat and power system in Denmark with different shares of district heating

    DEFF Research Database (Denmark)

    Zvingilaite, Erika; Balyk, Olexandr

    2014-01-01

    levels of heat savings, which can be implemented by reducing heat transmission losses through building elements and by installing ventilation systems with heat recovery, in different future Danish heat and power system scenarios. Today almost 50% of heat demand in Denmark is covered by district heating......The paper examines implementation of heat saving measures in buildings in 2050, under the assumption that heat and power supply comes solely from renewable resources in Denmark.Balmorel – a linear optimisation model of heat and power sectors in Denmark is used for investigating economically viable....... A further expansion of district heating network in Denmark is assessed and penetration of heat savings is analysed in this context.If all heat saving measures, included in the model, are implemented, heat demand in Danish buildings in 2050 could be reduced by around 40%. Results show that it is cost...

  10. Effects of social participation and the emergence of voluntary social interactions on household power-saving practices in post-disaster Kanagawa, Japan

    International Nuclear Information System (INIS)

    Nakamura, Hidenori

    2013-01-01

    An online social survey was conducted to reveal household electricity-saving behaviour and its relationship with participation in social group activities, as well as face-to-face and online social interactions, i.e., information sources used and information dissemination through personal networks, in a disaster-affected region of Kanagawa, Japan, during the summer of 2011. The study confirms the positive contribution of respondents’ participation in social group activities to the number of power-saving practices conducted. It also reveals the emergence of voluntary social face-to-face and/or online interactions for power-saving. The study suggests it would be useful to provide effective information to proactive individuals who are closely engaged in power-saving in households and who are proactively disseminating power-saving information practices to others. Such individuals include (1) women who have school-children and who are proactively engaging in the social interactions of their children’s schools, other parents, neighbours, as well as their own parents and relatives; and (2) men and women who are using various kinds of online interaction tools and are also engaged in face-to-face social interactions

  11. The power of strategy metaphors

    DEFF Research Database (Denmark)

    Lystbæk, Christian Tang; Holmgren, Jens

    2016-01-01

    and post-structuralism. The paper reports on an action research study of a strategy workshop with the strategic team of a Human Resource Management Department in a Danish Municipality. It identifies two structural dimensions and four generic spatial metaphors were identified. Thus, the paper shows......This paper explores the power of spatial metaphors in strategy making. I seek to unfold a conception of the power of spatial metaphors in strategy making that stresses their creative and critical capacity as well as their constraints on strategic thinking. In order to identify the power of spatial...

  12. A strategy for improving the profitability of utility power plants in a deregulated industry

    International Nuclear Information System (INIS)

    Reinhart, E.R.

    1996-01-01

    When deregulation of the utility industry becomes a reality in the near future, power plant managers and engineers will face a completely changed business climate. Surviving in a competitive business world will require a dramatic alteration in the way most utility power plants are maintained and upgraded, and in their budget planning. Strategies will have to be developed and implemented that follow the guidelines of good business practices in competitive industries. Some utilities have already started to reduce overhead maintenance costs. Key aspects of their programs can serve as examples to other utilities who want to develop a strategy to improve their operating cost effectiveness. Cost-cutting measures have included development of procedures and data bases that allowed utilities to become independent of original equipment manufacturer (OEM) support and to keep their costs for maintenance, repairs, and replacement of power plant components to a minimum. Also, scheduled power plant outages based on the concepts of reliability-centered maintenance (Smith, 1993), remaining life assessment, and advanced integrity monitors instead of a fixed calendar (Swanekamp, 1996), have allowed utilities to extend the time between some outages by several years. These and other innovative approaches will become critical to power plants operating in the new, deregulated business climate. Examples of actual cost savings are presented here

  13. An Indispensable Truth How Fusion Power Can Save the Planet

    CERN Document Server

    Chen, Francis F

    2011-01-01

    Both global warming and oil shortage can be solved by controlled fusion, a clean power source that will serve mankind for millennia.� The idea of hydrogen fusion as well as its difficulties are presented in non-technical language to dispel the notion that fusion is always 50 years away.� This book also summarizes the evidence for climate change and explains the principles of both fossil and "green" energy sources to show that fusion is the best alternative for central-station power in the near term as well as the far future. Praise for An Indispensable Truth: How Fusion Power Can Save the Planet: "In this study Professor Chen outlines the underlying physics, recent progress in achieving advanced plasmas and magnetic confinement, and hopes for the future. He recognizes the difficulties that remain in engineering a fusion reactor, but he remains optimistic regarding ultimate success, yet fearful of the consequences were we to fail."- James R. Schlesinger, former Chairman, Atomic Energy Commission; Director,...

  14. Power Saving Scheduling Scheme for Internet of Things over LTE/LTE-Advanced Networks

    Directory of Open Access Journals (Sweden)

    Yen-Wei Kuo

    2015-01-01

    Full Text Available The devices of Internet of Things (IoT will grow rapidly in the near future, and the power consumption and radio spectrum management will become the most critical issues in the IoT networks. Long Term Evolution (LTE technology will become a promising technology used in IoT networks due to its flat architecture, all-IP network, and greater spectrum efficiency. The 3rd Generation Partnership Project (3GPP specified the Discontinuous Reception (DRX to reduce device’s power consumption. However, the DRX may pose unexpected communication delay due to missing Physical Downlink Control Channel (PDCCH information in sleep mode. Recent studies mainly focus on optimizing DRX parameters to manage the tradeoff between the energy consumption and communication latency. In this paper, we proposed a fuzzy-based power saving scheduling scheme for IoT over the LTE/LTE-Advanced networks to deal with the issues of the radio resource management and power consumption from the scheduling and resource allocation perspective. The proposed scheme considers not only individual IoT device’s real-time requirement but also the overall network performance. The simulation results show that our proposed scheme can meet the requirements of the DRX cycle and scheduling latency and can save about half of energy consumption for IoT devices compared to conventional approaches.

  15. An ecological solution in power development strategy: hydroelectric Power

    International Nuclear Information System (INIS)

    Ionescu, S.; Teodorescu, D.

    1994-01-01

    One of the fundamental criteria in establishing the power development strategy is represented by the environmental protection. Besides increasing the power efficiency for users, the hydro power stands for a handy alternative to generate thermal power. Comparatively, if hydro power is properly planed and developed, it could allow conservation of fossil fuel resources (as it makes use of a renewable resources) and avoids air and water pollution and in addition would lead to certain positive effects upon the natural and anthropic environment (flood routing, optimizes the power supply-demand relationship, and so on). By making use of the data available in the international specific literature and the information on the power development strategy in Romania the effects incurred by hydro power are both qualitatively and quantitatively emphasized as compared to alternative power generation by fossil fuel combustion. The proposal is made to adopt certain law regulations as well as a methodology to evaluate the general efficiency of various types of power generating devices suiting the particular conditions of Romania and taking into account the social cost as well as environmental effects. Hence a power development strategy could be undertaking at the national level provided it meets the requirements of both power system and environment protection. (Author)

  16. A Downlink and Uplink Alignment Scheme for Power Saving in IEEE 802.16 Protocol

    Directory of Open Access Journals (Sweden)

    Jenhui Chen

    2014-01-01

    Full Text Available This study shows the problem of power saving mechanism (PSM that sleep intervals of uplink (UL connections do not synchronize with sleep intervals of downlink (DL connections. That is, the energy of a mobile station (MS is not really saved if the DL connections are in the sleep mode while the UL connections are in normal mode, and vice versa. To avoid the asynchronism of power saving (PS between UL and DL connections, we invent a mechanism of DL connections regulating UL connections, called DL and UL Alignment (DUAL scheme, to improve the energy efficiency for PS. Considering that the buffer size of MS is limited, DUAL uses the mean packet arrival rate of UL λu and a relatively safe threshold of buffer size QT as the parameters to estimate the maximum allowable waiting time to align the UL with the DL connections. To analyze the performance of DUAL, a system model of PS is proposed to evaluate the performance of DUAL under different conditions. The correctness of performance analysis of DUAL is validated by using simulation with realistic parameters. Numerical experiments show that DUAL improves the energy conservation significantly when UL traffic is greater than DL traffic.

  17. Flapping wing flight can save aerodynamic power compared to steady flight.

    Science.gov (United States)

    Pesavento, Umberto; Wang, Z Jane

    2009-09-11

    Flapping flight is more maneuverable than steady flight. It is debated whether this advantage is necessarily accompanied by a trade-off in the flight efficiency. Here we ask if any flapping motion exists that is aerodynamically more efficient than the optimal steady motion. We solve the Navier-Stokes equation governing the fluid dynamics around a 2D flapping wing, and determine the minimal aerodynamic power needed to support a specified weight. While most flapping wing motions are more costly than the optimal steady wing motion, we find that optimized flapping wing motions can save up to 27% of the aerodynamic power required by the optimal steady flight. We explain the cause of this energetic advantage.

  18. How much electricity can we save by using direct current circuits in homes? Understanding the potential for electricity savings and assessing feasibility of a transition towards DC powered buildings

    International Nuclear Information System (INIS)

    Glasgo, Brock; Azevedo, Inês Lima; Hendrickson, Chris

    2016-01-01

    Highlights: • DC distribution systems are analyzed using monitored appliance and solar PV data. • DC-distributed PV energy generates savings under real-world load and solar profiles. • Savings from direct-DC are generally not cost-effective in current markets. • Non-technical hurdles remain before DC can be widely adopted in US homes. - Abstract: Advances in semiconductor-based power electronics and growing direct current loads in buildings have led researchers to reconsider whether buildings should be wired with DC circuits to reduce power conversions and facilitate a transition to efficient DC appliances. The feasibility, energy savings, and economics of such systems have been assessed and proven in data centers and commercial buildings, but the outcomes are still uncertain for the residential sector. In this work, we assess the technical and economic feasibility of DC circuits using data for 120 traditionally-wired AC homes in Austin, Texas to understand the effect of highly variable demand profiles on DC-powered residences, using appliance-level use and solar generation data, and performing a Monte Carlo simulation to quantify costs and benefits. Results show site energy savings between 9% and 20% when solar PV is distributed to all home appliances. When battery storage for excess solar energy is considered, these savings increase to 14–25%. At present DC equipment prices, converting all equipment to DC causes levelized annual costs of electricity to homeowners to roughly double. However, by converting only homes’ air conditioning condensing units to DC, the costs of direct-DC are greatly reduced and home site energy savings of 7–16% are generated. In addition to quantifying savings, we find major nontechnical barriers to implementing direct-DC in homes. These include a lack of standards for such systems, a relatively small market for DC appliances and components, utility programs designed for AC power, and a workforce unfamiliar with DC

  19. An entry and exit model on the energy-saving investment strategy with real options

    International Nuclear Information System (INIS)

    Lin, Tyrone T.; Huang, S.-L.

    2010-01-01

    This paper presents an improved decision model based on the real options approach presented by for the firms that have not yet established energy-saving equipment under the entry and exit strategies. Furthermore, the proposed model takes account of the inevitable equipment renewal and the occurrence of unexpected events under the Poisson jump process. The timing for terminating an investment when continuous operations of that business are unprofitable is also explored to realize the optimal timing of implementing the energy-saving strategy. The future discounted benefit B follows the geometric Brownian motion with the Poisson jump process and the replacement of investment equipment. A numerical analysis is followed by a sensitivity study of various parameters to better realize their impacts on the entry and exit thresholds. The results show that for the jump case, the higher probability of occurrence of unfavorable events will result in a higher entry threshold and lower exit threshold. Investors are forced to request higher benefit thresholds to cover the higher probability of losses brought by unfavorable events.

  20. Mozambican Aggregate Consumption and Domestic Saving ...

    African Journals Online (AJOL)

    It was an unprecedented decade for its break with the previous trend; but so far, the new trend does not correspond to a substantial change in growth strategy to ensure that foreign savings become complementary rather than a substitute for domestic savings. Keywords: consumption, economic growth strategy, domestic ...

  1. Efficient use of power. Directory for private households to save power without renunciation of comfort; Strom effizient nutzen. Wegweiser fuer Privathaushalte zur wirtschaftlichen Stromeinsparung ohne Komfortverzicht

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-07-01

    The contribution under consideration is a guide for private households for an economically efficient conservation of electricity without renunciation of comfort. At first, reasons for saving electricity are presented. The approach to reduce power consumption consists of an inventory of electricity consumers, establishment of measures to save electricity as well as a selection of suitable measures. Tables are presented for the determination of the power consumption and costs for electricity in the actual and target state as well as for the determination of the economic efficiency.

  2. Energy-saving and emission-abatement potential of Chinese coal-fired power enterprise: A non-parametric analysis

    International Nuclear Information System (INIS)

    Wei, Chu; Löschel, Andreas; Liu, Bing

    2015-01-01

    In the context of soaring demand for electricity, mitigating and controlling greenhouse gas emissions is a great challenge for China's power sector. Increasing attention has been placed on the evaluation of energy efficiency and CO 2 abatement potential in the power sector. However, studies at the micro-level are relatively rare due to serious data limitations. This study uses the 2004 and 2008 Census data of Zhejiang province to construct a non-parametric frontier in order to assess the abatement space of energy and associated CO 2 emission from China's coal-fired power enterprises. A Weighted Russell Directional Distance Function (WRDDF) is applied to construct an energy-saving potential index and a CO 2 emission-abatement potential index. Both indicators depict the inefficiency level in terms of energy utilization and CO 2 emissions of electric power plants. Our results show a substantial variation of energy-saving potential and CO 2 abatement potential among enterprises. We find that large power enterprises are less efficient in 2004, but become more efficient than smaller enterprises in 2008. State-owned enterprises (SOE) are not significantly different in 2008 from 2004, but perform better than their non-SOE counterparts in 2008. This change in performance for large enterprises and SOE might be driven by the “top-1000 Enterprise Energy Conservation Action” that was implemented in 2006. - Highlights: • Energy-saving potential and CO 2 abatement-potential for Chinese power enterprise are evaluated. • The potential to curb energy and emission shows great variation and dynamic changes. • Large enterprise is less efficient than small enterprise in 2004, but more efficient in 2008. • The state-owned enterprise performs better than non-state-owned enterprise in 2008

  3. Electric Power Saving Awareness System at School Using ICT

    Directory of Open Access Journals (Sweden)

    Kuzume Koichi

    2016-01-01

    Full Text Available Nowadays, education on energy saving at schools attracts attention to reduce energy consumption. In this paper we proposed a novel system to promote energy conservation activity at schools using a sensor network. The system consisted of a wall-type clock embedded with several kinds of sensors for temperature and light in the classroom, and wireless devices to connect to a cloud computer network. The system had the following superiorities: offered various services for energy conservation activity, needless of CT (Current Transformer sensor, low price, ease of installation and extension, and visualization of power consumption in conjunction with school timetable in real time. We presented the system and a user study conducted to evaluate its usefulness.

  4. Investigations of heat-hydraulic noises in the equipment for creation of power-saving technologies

    International Nuclear Information System (INIS)

    Proskuryakov, K.N.

    2000-01-01

    The results of experimental and theoretical studies on the parameters of vibroacoustic signals, originating in the TPP and NPP thermal energy equipment, are presented. The methods for calculation and identification of the heat-hydraulic perturbation sources, intended for improving the means of early diagnostics of anomalies in the technological process, forecasting their development, increasing the maintenance work efficiency and operational safety, as well as for creating power-saving technologies in the power engineering, are developed [ru

  5. Public-opinion poll on energy saving

    International Nuclear Information System (INIS)

    1982-01-01

    A public-opinion poll was carried out on energy saving from November 26 to December 2, 1981, across the country. The number of persons participated in the survey was 5,000, whose age was 20 and above. The recovery ratio was 4,007 persons (80.1 %). The results of the survey and also the question-answer form are given with respective percentages. The questions were in the following three categories: (1) cognizance of energy saving - space-heating temperature, energy saving conscience use of private cars, purchase of highenergy consumption appliances; (2) energy for future - energy consumption, energy consumption trend, new types of energy, main sources of power generation, nuclear power in the overall electric power, apprehension toward nuclear power plants, safety measures in nuclear power plants; (3) governmental energy policy measures. (J.P.N.)

  6. Nash Equilibrium of an Energy Saving Strategy with Dual Rate Transmission in Wireless Regional Area Network

    Directory of Open Access Journals (Sweden)

    Zhanqiang Huo

    2017-01-01

    Full Text Available Wireless regional area network (WRAN adopts centralized network architecture and is currently one of the most typical cognitive radio networks. In order to reduce the energy consumption of the communication networks with the constraint of spectrum resource utilization, a working sleep mechanism is introduced into the base station (BS, and a novel energy saving strategy with dual rate transmission is proposed. Combining the multiple-vacation queue and priority queue, using the quasi-birth-death process and the matrix-geometric solution method, we assess the average latency and the forced termination probability of secondary user packets, as well as the energy saving ratio and the channel utilization of system. Based on the revenue-expenditure structure, a profit function is built, and then the Nash equilibrium behavior and the socially optimal behavior are investigated. With the help of the particle swarm optimization, an intelligent optimization algorithm to search the socially optimal arrival rate of secondary user packets is presented. In order to unify the arrival rates of secondary user packets with Nash equilibrium and social optimization, a reasonable pricing policy is formulated. In addition, system experiments are carried out to verify the effectiveness of the energy saving strategy and the rationality of the pricing policy.

  7. Dynamic Power-Saving Method for Wi-Fi Direct Based IoT Networks Considering Variable-Bit-Rate Video Traffic.

    Science.gov (United States)

    Jin, Meihua; Jung, Ji-Young; Lee, Jung-Ryun

    2016-10-12

    With the arrival of the era of Internet of Things (IoT), Wi-Fi Direct is becoming an emerging wireless technology that allows one to communicate through a direct connection between the mobile devices anytime, anywhere. In Wi-Fi Direct-based IoT networks, all devices are categorized by group of owner (GO) and client. Since portability is emphasized in Wi-Fi Direct devices, it is essential to control the energy consumption of a device very efficiently. In order to avoid unnecessary power consumed by GO, Wi-Fi Direct standard defines two power-saving methods: Opportunistic and Notice of Absence (NoA) power-saving methods. In this paper, we suggest an algorithm to enhance the energy efficiency of Wi-Fi Direct power-saving, considering the characteristics of multimedia video traffic. Proposed algorithm utilizes the statistical distribution for the size of video frames and adjusts the lengths of awake intervals in a beacon interval dynamically. In addition, considering the inter-dependency among video frames, the proposed algorithm ensures that a video frame having high priority is transmitted with higher probability than other frames having low priority. Simulation results show that the proposed method outperforms the traditional NoA method in terms of average delay and energy efficiency.

  8. Power Subscription Strategy: Administrator`s Record of Decision.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration

    1998-12-01

    The Bonneville Power Administration (BPA) has decided to adopt a Power Subscription Strategy for entering into new power sales contracts with its Pacific Northwest customers. The Strategy equitably distributes the electric power generated by the Federal Columbia River Power System (FCRPS) within the framework of existing law. The Power Subscription Strategy addresses the availability of power; describes power products; lays out strategies for pricing, including risk management; and discusses contract elements. In proceeding with this Subscription Strategy, BPA is guided by and committed to the Fish and Wildlife funding Principles for the BPA announced by the Vice President of the US in September 1998. This Record of Decision (ROD) addresses the issues raised by commenters who responded to BPA`s Power Subscription Strategy Proposal during and after the comment period that began with the release of the Proposal on September 18, 1998. The ROD is organized in approximately the same way as the Proposal and the Power Subscription Strategy that BPA developed based on the comments received. Abbreviations of party names used in citations appear in the section just preceding this introduction; a list of all the commenters follows the text of the ROD.

  9. Energy savings through self-backhauling for future heterogeneous networks

    International Nuclear Information System (INIS)

    Faruk, Nasir; Ruttik, Kalle; Mutafungwa, Edward; Jäntti, Riku

    2016-01-01

    Mobile operators face continuous challenge of enhancing network capacity and coverage so as to meet demand for ubiquitous high-speed mobile data connectivity. Unfortunately, these enhancements are typically accompanied by increased burden of network energy consumption. Heterogeneous network (HetNet) deployments of a large number of low power small base stations (SBS) to complement existing macro base stations is an approach that increases network capacity but potentially reduces overall network energy consumption. The SBS backhaul links in HetNets present a significant powering burden. In this paper, we show how self backhauling of SBS can reduce overall network power demand. A backhaul-energy consumption model is developed and used to investigate the energy efficiency of different backhauling options. We note that significant energy savings could be achieved through the use of self-backhauling when compared with the conventional microwave backhauling. The results presented would provide guidelines for energy- and cost-efficient backhaul implementation for future HetNets. - Highlights: • A backhaul-energy consumption model is developed. • Self backhauling of small base stations can reduce overall network power demand. • Energy saving strategy presented would relieved the burden on the power networks. • Results provide guidelines for energy and cost effective backhaul implementation.

  10. Force analysis of magnetic bearings with power-saving controls

    International Nuclear Information System (INIS)

    Johnson, D.; Brown, G.V.; Inman, D.J.

    1992-01-01

    Most magnetic bearing control schemes use a bias current with a superimposed control current to linearize the relationship between the control current and the force it delivers. For most operating conditions, the existence of the bias current requires more power than alternative methods that do not use conventional bias. Two such methods are examined which diminish or eliminate bias current. In the typical bias control scheme it is found that for a harmonic control force command into a voltage limited transconductance amplifier, the desired force output is obtained only up to certain combinations of force amplitude and frequency. Above these values, the force amplitude is reduced and a phase lag occurs. The power saving alternative control schemes typically exhibit such deficiencies at even lower command frequencies and amplitudes. To assess the severity of these effects, a time history analysis of the force output is performed for the bias method and the alternative methods. Results of the analysis show that the alternative approaches may be viable. The various control methods examined were mathematically modeled using nondimensionalized variables to facilitate comparison of the various methods

  11. Research on the energy-saving and revenue sharing strategy of ESCOs under the uncertainty of the value of Energy Performance Contracting Projects

    International Nuclear Information System (INIS)

    Qian, Dong; Guo, Ju’e

    2014-01-01

    Under the uncertainty of the value of Energy Performance Contracting Projects (EPCPs), this paper develops a revenue-sharing bargaining model between an Energy Service Company (ESCO) and an Energy-Using Organization (EU). Based on the model the paper analyzes the impacts of energy prices, risk-adjusted discount rates and accidents on the ESCO’s bargaining strategies. The research shows that the greater the probability of adverse circumstances is, the higher is the revenue share (of the EU), and the more disadvantageous is the ESCO’s position in the game. Furthermore, we design a forecast–commitment contract between an ESCO and an EU and analyze the optimal product’s energy savings commitment strategy of the ESCO to cope with uncertain energy savings and contract risk. The research illustrates that by introducing penalties and commitments, the contract can eliminate the impact of the uncertain energy savings on the contract execution to a certain extent; when the EU takes a greater commitment risk, the ESCO is willing to provide a higher commitment, thus enhancing the strategy value of the bilateral relationship and reducing the contract risk. Finally, the policy recommendations about improving shared savings contract standard, third-party energy savings measurement and verification mechanism and arbitration mechanism of EPCs are provided. - Highlights: • We provide a method for determining the revenue-sharing bargaining strategy space in a finite bargaining game of the ESCO. • The increase of the probability of adverse circumstances will increase the revenue share (of the EU). • We design a forecast–commitment contract between an ESCO and an EU. • The forecast–commitment contract can eliminate the impact of the uncertain energy savings on the contract execution to a certain extent. • When the EU takes a greater commitment risk, the ESCO is willing to provide a higher commitment

  12. Decommissioning of nuclear power plants: policies, strategies and costs

    International Nuclear Information System (INIS)

    Lund, I.

    2004-01-01

    As many nuclear power plants will reach the end of their lifetime during the next 20 years or so, decommissioning is an increasingly important topic for governments, regulators and industries. From a governmental viewpoint, particularly in a deregulated market, one essential aspect is to ensure that money for the decommissioning of nuclear installations will be available at the time it is needed, and that no 'stranded' liabilities will be left to be financed by the taxpayers rather than by the electricity consumers. For this reason, there is governmental interest in understanding decommissioning costs, and in periodically reviewing decommissioning cost estimates from nuclear installation owners. Robust cost estimates are key elements in designing and implementing a coherent and comprehensive national decommissioning policy including the legal and regulatory bases for the collection, saving and use of decommissioning funds. From the industry viewpoint, it is essential to assess and monitor decommissioning costs in order to develop a coherent decommissioning strategy that reflects national policy and assures worker and public safety, whilst also being cost effective. For these reasons, nuclear power plant owners are interested in understanding decommissioning costs as best as possible and in identifying major cost drivers, whether they be policy, strategy or 'physical' in nature. National policy considerations will guide the development of national regulations that are relevant for decommissioning activities. Following these policies and regulations, industrial managers responsible for decommissioning activities will develop strategies which best suit their needs, while appropriately meeting all government requirements. Decommissioning costs will be determined by technical and economic conditions, as well as by the strategy adopted. Against this backdrop, the study analyses the relationships among decommissioning policy as developed by governments, decommissioning

  13. Comprehensive evaluation and study on energy saving and emission reduction of nuclear power based on the osculation value method

    International Nuclear Information System (INIS)

    Liu Zhihui; Wei Fangxin; Liu Xiaomin

    2014-01-01

    By means of osculation value method, several provinces are selected to study the energy saving and emission reduction effect of nuclear power from provincial range according to the statistic data in 2010. Theoretically, nuclear power effect is reducing the consumption of non-renewable energy such as coal and reducing the release of pollutants such as CO 2 . The result shows that the comprehensive evaluation of energy saving and emission reduction effect in Zhejiang and Jiangsu provinces are the best. In comparison, Guangdong province falls behind Hubei and Fujian provinces. Total consumption of coal per unit of GDP in Guangdong, Zhejiang, and Jiangsu provinces is apparently lower than that of Hebei, Shanxi, Liaoning, and Hubei provinces. However, total release of SO 2 and NOx, etc. is apparently reduced in provinces with nuclear power, compared with provinces without nuclear power. But total release of CO 2 from thermal power generation (coal) per unit of GDP is not apparently reduced in provinces with nuclear power than those without. (authors)

  14. Feeding your piggy bank with intentions : A study on saving behaviour, saving strategies, and happiness

    NARCIS (Netherlands)

    De Francisco Vela, S.; Desmet, P.M.A.; Casais, M.

    2014-01-01

    The act of saving money can connect one’s present state to a meaningful future state, especially if we consider money not as a direct source of happiness, but as a resource for engaging in meaningful activities. To explore how design can contribute to making the act of saving more meaningful, we

  15. Nuclear power development strategy through 2020 in China

    International Nuclear Information System (INIS)

    Wang Yongping; Zhao Shoufeng; Yuan Yujun; Rao Shuang; Liu Qun; Ding Ruijie

    2005-10-01

    Through the analysis of the nuclear power situation of China, it is emphasized that the nuclear power development strategy is an important part of electric power development strategy and national energy security strategy in China, but nuclear power development in accelerant way will face greater challenge. The uranium demand and supply, the treatment and disposal of radioactive wastes, and other primary problems through 2020 in China are discussed. The nuclear power development strategy till 2020 are described. The relevant measures and recommendations are proposed. (authors)

  16. Energy security strategy and nuclear power

    International Nuclear Information System (INIS)

    Toichi, Tsutomu; Shibata, Masaharu; Uchiyama, Yoji; Suzuki, Tatsujiro; Yamazaki, Kazuo

    2006-01-01

    This special edition of 'Energy security strategy and nuclear power' is abstracts of the 27 th Policy Recommendations 'The Establishment of an International Energy Security System' by the Japan Forum on International Relations, Inc on May 18 th , 2006. It consists of five papers: Energy security trend in the world and Japan strategy by Tsutomu Toichi, Establishment of energy strategy supporting Japan as the focus on energy security by Masaharu Shibata, World pays attention to Japan nuclear power policy and nuclear fuel cycle by Yoji Uchiyama, Part of nuclear power in the energy security - the basic approach and future problems by Tatsujiro Suzuki, and Drawing up the energy strategy focused on the national interests - a demand for the next government by Kazuo Yamazaki. (S.Y.)

  17. Energy Saving Alignment Strategy: Achieving energy efficiency in urban buildings by matching occupant temperature preferences with a building’s indoor thermal environment

    International Nuclear Information System (INIS)

    Xu, Xiaoqi; Culligan, Patricia J.; Taylor, John E.

    2014-01-01

    Highlights: • A novel strategy for energy savings in multi-family buildings is presented. • A household’s thermal preferences are matched with a unit’s thermal environment. • Potential energy savings are examined using public housing as a test case. • 2.1–42.0% primary energy savings are shown, depending on climate location. - Abstract: Existing strategies for residential energy savings through physical renovation or motivating occupant energy conservation behavior can be costly and/or have transitory effects. Focusing on multi-family dwellings, an important subset of the urban residential sector, we propose an Energy Saving Alignment Strategy (ESAS) that has advantageous cost-effectiveness and a long-lasting influence. By aligning the distribution of residents’ thermostat preferences with the indoor temperature, ESAS aims to maximize thermal comfort and, accordingly, energy savings in multi-family buildings where indoor temperatures vary between apartments as a function of apartment orientation and floor level. Using a case study of a 1084-apartment public housing complex in New York, we classify both occupants’ thermostat preferences and apartments’ operative temperatures into five groups, and optimize energy efficiency by assigning each group of occupants to the group of apartments that best aligns with their thermostat preference. We test ESAS in eight cities representing all four U.S. census regions and six climate zones. Simulation results reveal 2.1–42.0% in energy savings compared to random apartment assignments depending on geographic location, with the highest energy reductions occurring in cities with mild climates, where the range of occupant thermostat preferences coincides with the natural indoor temperature range. We conclude by providing suggested guidelines on how ESAS might work in practice, and recommendations for extending ESAS research

  18. An objective decision model of power grid environmental protection based on environmental influence index and energy-saving and emission-reducing index

    Science.gov (United States)

    Feng, Jun-shu; Jin, Yan-ming; Hao, Wei-hua

    2017-01-01

    Based on modelling the environmental influence index of power transmission and transformation project and energy-saving and emission-reducing index of source-grid-load of power system, this paper establishes an objective decision model of power grid environmental protection, with constraints of power grid environmental protection objectives being legal and economical, and considering both positive and negative influences of grid on the environmental in all-life grid cycle. This model can be used to guide the programming work of power grid environmental protection. A numerical simulation of Jiangsu province’s power grid environmental protection objective decision model has been operated, and the results shows that the maximum goal of energy-saving and emission-reducing benefits would be reached firstly as investment increasing, and then the minimum goal of environmental influence.

  19. Modeling nexus of urban heat island mitigation strategies with electricity/power usage and consumer costs: a case study for Phoenix, Arizona, USA

    Science.gov (United States)

    Silva, Humberto; Fillpot, Baron S.

    2018-01-01

    A reduction in both power and electricity usage was determined using a previously validated zero-dimensional energy balance model that implements mitigation strategies used to reduce the urban heat island (UHI) effect. The established model has been applied to show the change in urban characteristic temperature when executing four common mitigation strategies: increasing the overall (1) emissivity, (2) vegetated area, (3) thermal conductivity, and (4) albedo of the urban environment in a series of increases by 5, 10, 15, and 20% from baseline values. Separately, a correlation analysis was performed involving meteorological data and total daily energy (TDE) consumption where the 24-h average temperature was shown to have the greatest correlation to electricity service data in the Phoenix, Arizona, USA, metropolitan region. A methodology was then developed for using the model to predict TDE consumption reduction and corresponding cost-saving analysis when implementing the four mitigation strategies. The four modeled UHI mitigation strategies, taken in combination, would lead to the largest percent reduction in annual energy usage, where increasing the thermal conductivity is the single most effective mitigation strategy. The single least effective mitigation strategy, increasing the emissivity by 5% from the baseline value, resulted in an average calculated reduction of about 1570 GWh in yearly energy usage with a corresponding 157 million dollar cost savings. When the four parameters were increased in unison by 20% from baseline values, an average calculated reduction of about 2050 GWh in yearly energy usage was predicted with a corresponding 205 million dollar cost savings.

  20. Energy-saving modification on outdoor lighting in the nuclear power plant

    International Nuclear Information System (INIS)

    Yao Bo

    2010-01-01

    The outdoor lighting in the nuclear power plant don't automatically shut down,and cause lights to be long-light. It is proposed to install light-control switches in the electric circuit in order to achieve automatic control. The original outdoor lighting circuit uses the circuit breaker for over-current protection and short circuit fault protection, and use remote circuit breaker to manually operate the lamp on and off.Each circuit branch installs a light-control switch, and set the threshold of 100 lux for the light-control switch. When the natural illumination meet the minimum illumination requirement (> 100lux), the lights shut down the power.When natural illumination doesn't meet the lighting requirement (<100lux), the lighting automatically close.After the modification, it is resolved the outdoor lighting easily becoming a long light,and save energy. (authors)

  1. Energy savings and economics of advanced control strategies for packaged air conditioners with gas heat

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Weimin; Katipamula, Srinivas; Huang, Yunzhi; Brambley, Michael R.

    2013-10-01

    This paper presents an evaluation of the potential energy savings from adding advanced control to existing packaged air conditioners. Advanced control options include air-side economizer, multi-speed fan control, demand control ventilation and staged cooling. The energy and cost savings from the different control strategies individually and in combination are estimated using the EnergyPlus detailed energy simulation program for four building types, namely, a small office building, a stand-alone retail building, a strip mall building and a supermarket building. For each of the four building types, the simulation was run for 16 locations covering all 15 climate zones in the U.S. The maximum installed cost of a replacement controller that provides acceptable payback periods to owners is estimated.

  2. Fast Control Channel Decoding for LTE UE Power Saving

    DEFF Research Database (Denmark)

    Lauridsen, Mads; Jensen, Anders Riis; Mogensen, Preben

    2012-01-01

    in the current TTI. The cost is that some reference signals are not received leading to a degraded channel estimate. Calculations show that this causes an SINR degradation of approximately 0.5 dB, which will result in maximum 4 % throughput loss. Comparing this with energy saving potentials of 5 %-25...... % it is concluded that the FCCD method is a valuable aid to prolong LTE phones' battery lifetime. The results are generated using a two state Markov chain model to simulate traffic and scheduling, and verified mathematically. The work also includes an examination of various data traffic types' on/off relation...... and an evaluation of how the relation affects power consumption. The FCCD method can complement DRX sleep mode since it is applicable when the signal is too aperiodic or fast switching for DRX....

  3. Modelling energy savings in the Danish building sector combined with internalisation of health related externalities in a heat and power system optimisation model

    International Nuclear Information System (INIS)

    Zvingilaite, Erika

    2013-01-01

    A substantial untapped energy saving potential rests in the building sector and is expected to play an important role in achieving reduction of environmental impacts of energy. In order to utilise this potential, effective policy measures need to be adopted to remove the existing barriers and create incentives. For that purpose, the cost effective energy saving options together with an optimal level of savings and expected environmental benefits have to be identified. The paper reports on a study that analyses these questions by including heat-saving measures in buildings into an energy system optimisation model of the Danish heat and power sector. The achieved optimal level of heat savings reaches 11% of projected heat demand in 2025 under the model assumptions. Moreover, the analysis reveals the importance of considering energy conservation options in a system wide perspective. Furthermore, the results suggest that changes in the energy generation sector are the prime driver behind the reduction of environmental externalities of energy. Heat savings in buildings play only a small role under model assumptions. - Highlights: ► Heat savings in buildings are analysed together with a heat and power system. ► Heat savings compete with electricity to heat technologies, mainly heat pumps. ► Cost effective heat-savings bring small decrease in health impacts and CO 2 emissions. ► Cost-effectiveness of heat savings depends on the marginal heat generation technology

  4. Energy savings: persuasion and persistence

    Energy Technology Data Exchange (ETDEWEB)

    Eijadi, David; McDougall, Tom; Leaf, Kris; Douglas, Jim; Steinbock, Jason; Reimer, Paul [The Weidt Group, Minnetonka, MN (United States); Gauthier, Julia [Xcel Energy, Minneapolis, MN (United States); Wild, Doug; Richards McDaniel, Stephanie [BWBR Architects, Inc., Saint Paul, MN (United States)

    2005-07-01

    In this study, the architects, sponsoring utility and energy simulation specialist joined together to investigate the persistence of energy savings in three completed projects: a college library; a municipal transportation facility; and a hospital. The primary question being 'How well did the design decisions made with the help of simulation analysis translate into building operations over several years?' Design simulation and metered performance data are compared for specific energy-saving strategies. The paper provides a brief overview of the basis of selection of the three projects, the energy design assistance methods employed and the decisions made, along with their savings expectations. For each case, design characteristics, modelling assumptions, selected strategies and actual metered performance are outlined. We find evidence of appropriate levels of energy conservation, but they are not the absolute values predicted. In each case, the discrepancies between modelling assumptions and final construction or operating procedures are identified, examined and rectified. The paper illustrates that while owners are saving energy, they are not always getting the full savings potential for what they install. The paper concludes with a re-examination of the overall process. It evaluates the potential for additional savings of individual technologies and related larger utility incentives to design teams and building owners.

  5. Optimized Power Dispatch Strategy for Offshore Wind Farms

    DEFF Research Database (Denmark)

    Hou, Peng; Hu, Weihao; Zhang, Baohua

    2016-01-01

    which are related to electrical system topology. This paper proposed an optimized power dispatch strategy (OPD) for minimizing the levelized production cost (LPC) of a wind farm. Particle swarm optimization (PSO) is employed to obtain final solution for the optimization problem. Both regular shape......Maximizing the power production of offshore wind farms using proper control strategy has become an important issue for wind farm operators. However, the power transmitted to the onshore substation (OS) is not only related to the power production of each wind turbine (WT) but also the power losses...... and irregular shape wind farm are chosen for the case study. The proposed dispatch strategy is compared with two other control strategies. The simulation results show the effectiveness of the proposed strategy....

  6. Strategies for growth of thermal power

    International Nuclear Information System (INIS)

    Shah, R.K.D.

    1998-01-01

    The power generating industry in India is at the cross roads. Massive investments are required to achieve GDP growth of 7-8% per annum over the next 10 years. For this, appropriate strategies have to be evolved which will give the country best returns. With coal being the major fuel resource in India, thermal power generation will continue to be the mainstay in the next decade. This paper covers various key issues to be addressed covering the plan and perspectives of thermal power, environmental issues, technology strategies for growth, power policy and R and D. (author)

  7. Disagreement at the Academy: discursive strategies to protect and save speakers' face

    Directory of Open Access Journals (Sweden)

    Verbena Lúcia Medeiros Costa

    2012-10-01

    Full Text Available Our aim in this study is to investigate the linguistic strategies professors use at the University to mitigate their disagreements, reach their academic and scientific interests and save each others’ face. Disagreement is a threatening speech act which threatens the individual’s positive face. It implies criticism, disapproval and contradicts our desire to be socially approved and appreciated. At the Academy it seems to be much more complex, hence the necessity to be studied. Our study is based on Brown and Levinson’s Politeness Theory (1978, 1987; on Goffman’s idea of face (1967 and on some assumptions of Conversation Analysis. The result suggests that professors care about each other’s face and also about their social relationships and, to preserve them, use different mitigating strategies, but they will not hesitate to prove that their ideas are the most reasonable and must be adopted.

  8. Acquiring energy savings in manufactured housing

    International Nuclear Information System (INIS)

    Davey, D.

    1993-01-01

    In 1991, the Northwest utilities faced a complex situation. They needed new sources of electrical power to avoid future deficits. A significant block of energy savings was available in the manufactured housing sector in the form of energy savings from increased insulation to new manufactured homes. The manufacturers were interested in saving the electricity in the homes, but would only deal with the utility sector as a whole. Half of the homes targeted were sited in investor-owned utility (IOU) service territories, and half in the public sector made up of utilities that purchased some or all of their electricity from the Bonneville Power Administration. Utilities agreed to acquire energy from manufacturers In the form of thermal efficiency measures specified by the Bonneville Power Administration. The program that resulted from over one year of negotiations was called the Manufactured Housing Acquisition Program, or MAP. Manufacturers, the utilities, State Energy Offices, the Northwest Power Planning Council and Bonneville all worked closely and with tenacity to build the program that went into effect on April 1, 1992, and should save the region between 7 and 9 megawatts, enough energy to supply 11,000 homes in the Northwest

  9. Power load leveling and energy saving measures for office buildings. Power load leveling and energy saving technology for the new building of the Kobe branch of the Kansai Electric Power Co., and its effect; Office biru no denryoku fuka heijunka sho energy hosaku. Kobe shiten shinshaoku ni okeru denryoku fuka heijunka sho energy gijutsu to sono koka

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiyama, M. [Kansai Electric Power Co. Inc., Osaka (Japan)

    1999-06-10

    This paper presents power load leveling and energy saving measures for heat source, air conditioning and lighting of the new Kobe branch building. The low-temperature hot-air system adopts an ice storage system, and reduces blowing power by 12 degreesC blowing in place of normal 16 degreesC blowing, and an initial cost by duct size reduction. The continuous air conditioning system levels an initial peak load of air conditioning as compared with normal air conditioning only for working hours for buildings with large heat capacity. In addition, as power load leveling measures for the whole building, the complete heat storage system using an underground internal melting type ice storage tank is adopted. Energy saving for lighting is achieved with a dimming lighting controlling its lighting output by inverter. The following effects are expected by these new technologies: Load leveling effect of 30%, energy saving effect of 20.2% and CO{sub 2} reduction effect of 24.1%. (NEDO)

  10. What Strategies Do Physicians and Patients Discuss to Reduce Out-of-Pocket Costs? Analysis of Cost-Saving Strategies in 1,755 Outpatient Clinic Visits.

    Science.gov (United States)

    Hunter, Wynn G; Zhang, Cecilia Z; Hesson, Ashley; Davis, J Kelly; Kirby, Christine; Williamson, Lillie D; Barnett, Jamison A; Ubel, Peter A

    2016-10-01

    More than 1 in 4 Americans report difficulty paying medical bills. Cost-reducing strategies discussed during outpatient physician visits remain poorly characterized. We sought to determine how often patients and physicians discuss health care costs during outpatient visits and what strategies, if any, they discussed to lower patient out-of-pocket costs. Retrospective analysis of dialogue from 1,755 outpatient visits in community-based practices nationwide from 2010 to 2014. The study population included 677 patients with breast cancer, 422 with depression, and 656 with rheumatoid arthritis visiting 56 oncologists, 36 psychiatrists, and 26 rheumatologists, respectively. Thirty percent of visits contained cost conversations (95% confidence interval [CI], 28 to 32). Forty-four percent of cost conversations involved discussion of cost-saving strategies (95% CI, 40 to 48; median duration, 68 s). We identified 4 strategies to lower costs without changing the care plan. They were, in order of overall frequency: 1) changing logistics of care, 2) facilitating co-pay assistance, 3) providing free samples, and 4) changing/adding insurance plans. We also identified 4 strategies to reduce costs by changing the care plan: 1) switching to lower-cost alternative therapy/diagnostic, 2) switching from brand name to generic, 3) changing dosage/frequency, and 4) stopping/withholding interventions. Strategies were relatively consistent across health conditions, except for switching to a lower-cost alternative (more common in breast oncology) and providing free samples (more common in depression). Focus on 3 conditions with potentially high out-of-pocket costs. Despite price opacity, physicians and patients discuss a variety of out-of-pocket cost reduction strategies during clinic visits. Almost half of cost discussions mention 1 or more cost-saving strategies, with more frequent mention of those not requiring care-plan changes. © The Author(s) 2016.

  11. A Location Selection Policy of Live Virtual Machine Migration for Power Saving and Load Balancing

    Directory of Open Access Journals (Sweden)

    Jia Zhao

    2013-01-01

    Full Text Available Green cloud data center has become a research hotspot of virtualized cloud computing architecture. And load balancing has also been one of the most important goals in cloud data centers. Since live virtual machine (VM migration technology is widely used and studied in cloud computing, we have focused on location selection (migration policy of live VM migration for power saving and load balancing. We propose a novel approach MOGA-LS, which is a heuristic and self-adaptive multiobjective optimization algorithm based on the improved genetic algorithm (GA. This paper has presented the specific design and implementation of MOGA-LS such as the design of the genetic operators, fitness values, and elitism. We have introduced the Pareto dominance theory and the simulated annealing (SA idea into MOGA-LS and have presented the specific process to get the final solution, and thus, the whole approach achieves a long-term efficient optimization for power saving and load balancing. The experimental results demonstrate that MOGA-LS evidently reduces the total incremental power consumption and better protects the performance of VM migration and achieves the balancing of system load compared with the existing research. It makes the result of live VM migration more high-effective and meaningful.

  12. A location selection policy of live virtual machine migration for power saving and load balancing.

    Science.gov (United States)

    Zhao, Jia; Ding, Yan; Xu, Gaochao; Hu, Liang; Dong, Yushuang; Fu, Xiaodong

    2013-01-01

    Green cloud data center has become a research hotspot of virtualized cloud computing architecture. And load balancing has also been one of the most important goals in cloud data centers. Since live virtual machine (VM) migration technology is widely used and studied in cloud computing, we have focused on location selection (migration policy) of live VM migration for power saving and load balancing. We propose a novel approach MOGA-LS, which is a heuristic and self-adaptive multiobjective optimization algorithm based on the improved genetic algorithm (GA). This paper has presented the specific design and implementation of MOGA-LS such as the design of the genetic operators, fitness values, and elitism. We have introduced the Pareto dominance theory and the simulated annealing (SA) idea into MOGA-LS and have presented the specific process to get the final solution, and thus, the whole approach achieves a long-term efficient optimization for power saving and load balancing. The experimental results demonstrate that MOGA-LS evidently reduces the total incremental power consumption and better protects the performance of VM migration and achieves the balancing of system load compared with the existing research. It makes the result of live VM migration more high-effective and meaningful.

  13. National strategy of nuclear power intellectual property

    International Nuclear Information System (INIS)

    Bo Huaitao

    2008-01-01

    The IP strategy includes four strategic levels: international level, national level, industry level and enterprise level. The national nuclear power IP strategy is an industry level strategy, which is also one part of national IP strategy, permeating with the IP strategy of the international level and enterprise level mutually. Commencing from the angles of the national level and the industry level, the author tries to provide a reference for IP strategy by an initial study about IP strategy in nuclear power industry.. The author holds that independent innovation is at the root of strategic establishment; enterprise is the main body for strategic implementation; and evaluating index must be consummated in the strategic evaluation. (authors)

  14. Axial power deviation control strategy and computer simulation for Daya Bay Nuclear Power Station

    International Nuclear Information System (INIS)

    Liao Yehong; Zhou Xiaoling, Xiao Min

    2004-01-01

    Daya Bay Nuclear Power Station has very tight operation diagram especially at its right side. Therefore the successful control of axial power deviation for PWR is crucial to nuclear safety. After analyzing various core characters' effect on axial power distribution, several axial power deviation control strategies has been proposed to comply with different power varying operation scenario. Application and computer simulation of the strategies has shown that our prediction of axial power deviation evolution are comparable to the measurement values, and that our control strategies are effective. Engineering experience shows that the application of our methodology can predict accurately the transient of axial power deviation, and therefore has become a useful tool for reactor operation and safety control. This paper presents the axial power control characteristics, reactor operation strategy research, computer simulation, and comparison to measurement results in Daya Bay Nuclear Power Station. (author)

  15. Russian Energy Strategy and development of renewable power industry

    OpenAIRE

    Bazhanov, Andrei; Tyukhov, Igor

    2008-01-01

    We consider two scenarios of the development of renewable power industry in Russia on an example of the Dasgupta-Heal-Solow-Stiglitz model. We assume that the resource rent is being invested into capital in the form of renewable power technologies according to the standard Hartwick saving rule. We use the modified Hotelling rule that reflects externalities implying, in particular, growing rates of oil extraction. We have shown that the growing extraction, prescribed by the Russian Energy Stra...

  16. Geology of Woman Saving Concept

    Directory of Open Access Journals (Sweden)

    Shayesteh Madani

    2014-09-01

    Full Text Available Money is lubricant and an instrument for economic transaction. Money social dimension has increased over time, transforming it from a sole economic instrument to a device for various transactions. Money economic value in society is indicated through different forms, one of which is saving, in the sense of money accumulation and its use under specific future circumstances. Women, who form half of the society, take specific approaches to money and savings. The current research aims to investigate the perspectives and changing attitude strategy to money and saving among married women. The participants of this study include 20 to 70 year-old employed household married women who were observed phenomenologically and interviewed qualitatively on saving through.   The findings of this study demonstrated women perspectives on various types of saving, ways of saving, transfer methods, saving consumption forms and their mechanism. It also revealed that while money is an economic instrument and possess the economic material; attitudes and acts related to money are influenced by social conditions that has consequently turned saving into a social phenomenon.

  17. Linking fuel design features ampersand plant management to uranium, SWU savings

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This article, contributed by Scott Garrett, Manager of Planning and Uranium Operations for Siemens Power Corporation in Bellevue, Washington, explores the impact of advances in fuel design and fuel management strategies on uranium utilization in the United States. Nuclear plant operators are deriving substantial benefits from these changes, including longer fuel cycle lengths, increased burnup, and added capacity - and experiencing cost savings in both uranium and enrichment services at the same time

  18. Power saving regulated light emitting diode circuit

    International Nuclear Information System (INIS)

    Haville, G. D.

    1985-01-01

    A power saving regulated light source circuit, comprising a light emitting diode (LED), a direct current source and a switching transistor connected in series with the LED, a control voltage producing resistor connected in series with the LED to produce a control voltage corresponding to the current through the LED, a storage capacitor connected in parallel with the series combination of the LED and the resistor, a comparator having its output connected to the input of the transistor, the comparator having a reference input and a control input, a stabilized biasing source for supplying a stabilized reference voltage to the reference input, the control input of the comparator being connected to the control voltage producing resistor, the comparator having a high output state when the reference voltage exceeds the control voltage while having a low output state when the control voltage exceeds the reference voltage, the transistor being conductive in response to the high state while being nonconductive in response to the low state, the transistor when conductive being effective to charge the capacitor and to increase the control voltage, whereby the comparator is cycled between the high and low output states while the transistor is cycled between conductive and nonconductive states

  19. Evaluation of Advanced Data Centre Power Management Strategies

    NARCIS (Netherlands)

    Postema, Björn F.; Haverkort, Boudewijn R.

    2018-01-01

    In recent work, we proposed a new specification language for power management strategies as an extension to our AnyLogic-based simulation framework for the trade-off analysis of power and performance in data centres. In this paper, we study the quality of such advanced power management strategies

  20. Optimized efficiency of all-electric ships by dc hybrid power systems

    Science.gov (United States)

    Zahedi, Bijan; Norum, Lars E.; Ludvigsen, Kristine B.

    2014-06-01

    Hybrid power systems with dc distribution are being considered for commercial marine vessels to comply with new stringent environmental regulations, and to achieve higher fuel economy. In this paper, detailed efficiency analysis of a shipboard dc hybrid power system is carried out. An optimization algorithm is proposed to minimize fuel consumption under various loading conditions. The studied system includes diesel engines, synchronous generator-rectifier units, a full-bridge bidirectional converter, and a Li-Ion battery bank as energy storage. In order to evaluate potential fuel saving provided by such a system, an online optimization strategy for fuel consumption is implemented. An Offshore Support Vessel (OSV) is simulated over different operating modes using the online control strategy. The resulted consumed fuel in the simulation is compared to that of a conventional ac power system, and also a dc power system without energy storage. The results show that while the dc system without energy storage provides noticeable fuel saving compared to the conventional ac system, optimal utilization of the energy storage in the dc system results in twice as much fuel saving.

  1. Study on emergency power control strategy for AC/DC hybrid power system containing VSC-HVDC

    Science.gov (United States)

    Liu, Lin; Hu, Zhenda; Ye, Rong; Lin, Zhangsui; Yang, Xiaodong; Yi, Yang

    2018-04-01

    This paper presents a comprehensive emergency power control strategy for AC/DC hybrid power systems containing VSC-HVDC. Firstly, the paper analyzes the power support of the VSC-HVDC to the AC lines using the Power Transferring Relativity Factor (PTRF). Then the power adjustment of the VSC-HVDC in several different circumstances are calculated. Finally, the online power control strategies of VSC-HVDC are designed, which could rapidly control the power of the VSC-HVDC, keeping the power flow of AC lines below the upper limit. Furthermore, the strategy is proven to be effective by the simulations with EMTDC/PSCAD.

  2. Is It Worth Saving?: The Condition of Archaeological Documentary Record and Strategies for Preservation

    Directory of Open Access Journals (Sweden)

    Douglas R. Givens

    1992-11-01

    Full Text Available "[Historical] objects are events which have finished happening, and conditions [are] no longer in existence. Only when they are no longer perceptible do they become objects of historical thought" (Collingwood 1946:233. Scholars engaged in research in the history of anthropology and archaeology have long been aware of the deplorable conditions in which records as to anthropology's development in time are found and stored. All too often the researcher finds records in individual and institutional hands that are physically degrading because of the lack of proper storage facilities, the fiscal inability to hire professional archivists, the usage of improper methods of acquisition and curation, and dwindling financial resources to properly care for materials. It is now the time to ask if anthropological records are worth saving, and if they are, what are the best strategies to be employed to ensure their survival and protection now and into the future. The purpose of this paper is to suggest that the records of the subdiscipline of archaeology are worth saving and that there is a great sense of urgency to get about the business of identification and preservation before archaeological documentary records are further destroyed due to neglect and the lack of means to ensure their future existence.  This paper will define the problems of identification and preservation of archaeological records as they exist now and suggest strategies to rectify those problems.

  3. Should the next standby power target be 0-watt?

    Energy Technology Data Exchange (ETDEWEB)

    Meier, Alan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Technologies Area; Siderius, Hans-Paul [Rijksdienst voor Ondernemend (Netherlands)

    2017-06-29

    The standby power use of appliances continues to consume large amounts of electricity. Considerable success has been made in reducing each device’s use, but these savings have been offset by a huge increase in the number of products using standby power and new power requirements for maintaining network connections. Current strategies to reduce standby have limitations and may not be most appropriate for emerging energy consumption trends. A new strategy for further reductions in standby, the “Standzero” option, encourages electrical products to be designed to operate for short periods without relying on mains-supplied electricity. Energy savings are achieved through enhanced efficiency and by harvesting ambient energy. A sensitivity analysis suggests many appliances could be designed to operate for at least an hour without relying on mains power and, in some cases, may be able to operate indefinitely at zero watts until activated.

  4. Implementation of an optical diagnosis strategy saves costs and does not impair clinical outcomes of a fecal immunochemical test-based colorectal cancer screening program.

    Science.gov (United States)

    Vleugels, Jasper L A; Greuter, Marjolein J E; Hazewinkel, Yark; Coupé, Veerle M H; Dekker, Evelien

    2017-12-01

     In an optical diagnosis strategy, diminutive polyps that are endoscopically characterized with high confidence are removed without histopathological analysis and distal hyperplastic polyps are left in situ. We evaluated the effectiveness and costs of optical diagnosis.  Using the Adenoma and Serrated pathway to Colorectal CAncer (ASCCA) model, we simulated biennial fecal immunochemical test (FIT) screening in individuals aged 55 - 75 years. In this program, we compared an optical diagnosis strategy with current histopathology assessment of all diminutive polyps. Base-case assumptions included 76 % high-confidence predictions and sensitivities of 88 %, 91 %, and 88 % for endoscopically characterizing adenomas, sessile serrated polyps, and hyperplastic polyps, respectively. Outcomes were colorectal cancer burden, number of colonoscopies, life-years, and costs.  Both the histopathology strategy and the optical diagnosis strategy resulted in 21 life-days gained per simulated individual compared with no screening. For optical diagnosis, €6 per individual was saved compared with the current histopathology strategy. These cost savings were related to a 31 % reduction in colonoscopies in which histopathology was needed for diminutive polyps. Projecting these results onto the Netherlands (17 million inhabitants), assuming a fully implemented FIT-based screening program, resulted in an annual undiscounted cost saving of € 1.7 - 2.2 million for optical diagnosis.  Implementation of optical diagnosis in a FIT-based screening program saves costs without decreasing program effectiveness when compared with current histopathology analysis of all diminutive polyps. Further work is required to evaluate how endoscopists participating in a screening program should be trained, audited, and monitored to achieve adequate competence in optical diagnosis.

  5. Energy Savings and Economics of Advanced Control Strategies for Packaged Air-Conditioning Units with Gas Heat

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Weimin; Katipamula, Srinivas; Huang, Yunzhi; Brambley, Michael R.

    2011-12-31

    Pacific Northwest National Laboratory (PNNL) with funding from the U.S. Department of Energy's Building Technologies Program (BTP) evaluated a number of control strategies that can be implemented in a controller, to improve the operational efficiency of the packaged air conditioning units. The two primary objectives of this research project are: (1) determine the magnitude of energy savings achievable by retrofitting existing packaged air conditioning units with advanced control strategies not ordinarily used for packaged units and (2) estimating what the installed cost of a replacement control with the desired features should be in various regions of the U.S. This document reports results of the study.

  6. Health care costs: saving in the private sector.

    Science.gov (United States)

    Robeson, F E

    1979-01-01

    Robeson offers a number of options to employers to help reduce the impact of increasing health care costs. He points out that large organizations which employ hundreds of people have considerable market power which can be exerted to contain costs. It is suggested that the risk management departments assume the responsibility for managing the effort to reduce the costs of medical care and of the health insurance programs of these organizations since that staff is experienced at evaluating premiums and negotiating with third-party payors. The article examines a number of short-run strategies for firms to pursue to contain health care costs: (1) use alternative delivery systems such as health maintenance organizations (HMOs) which have cost-cutting potential but require marketing efforts to persuade employees of their desirability; (2) contracts with third-party payors which require a second opinion (peer review), a practice which saved one labor union over $2 million from 1972 to 1976; (3) implementation of insurance coverage for less expensive outpatient care; and (4) the use of claims review. These strategies are compared in terms of four criteria: supply of demand for health services; management effort; cost; and time necessary for realized savings. Robeson concludes that development of a management plan for containing health care costs requires an extensive analysis of alternatives, organizational objectives, existing policies, and resources, and offers a table summarizing the cost-containment strategies that a firm should consider.

  7. Axial power difference control strategy and computer simulation for GNPS during stretch-out and power decrease

    International Nuclear Information System (INIS)

    Liao Yehong; Xiao Min; Li Xianfeng; Zhu Minhong

    2004-01-01

    Successful control of the axial power difference for PWR is crucial to nuclear safety. After analyzing various elements' effect on the axial power distribution, different axial power deviation control strategies have been proposed to comply with different power decrease scenarios. Application of the strategy to computer simulation shows that our prediction of axial power deviation evolution is comparable to the measurement value, and that our control strategy is effective

  8. Energy consumption and energy-saving potential analysis of pollutant abatement systems in a 1000MW coal-fired power plant.

    Science.gov (United States)

    Yang, Hang; Zhang, Yongxin; Zheng, Chenghang; Wu, Xuecheng; Chen, Linghong; Gao, Xiang; Fu, Joshua S

    2018-05-10

    The pollutant abatement systems are widely applied in the coal-fired power sector and the energy consumption was considered an important part of the auxiliary power. An energy consumption analysis and assessment model of pollutant abatement systems in a power unit was developed based on the dynamic parameters and technology. The energy consumption of pollutant abatement systems in a 1000 MW coal-fired power unit which meet the ultra-low emission limits and the factors of operating parameters including unit load and inlet concentration of pollutants on the operating power were analyzed. The results show that the total power consumption of the pollutant abatement systems accounted for 1.27% of the gross power generation during the monitoring period. The WFGD system consumed 67% of the rate while the SCR and ESP systems consumed 8.9% and 24.1%. The power consumption rate of pollutant abatement systems decreased with the increase of unit load and increased with the increase of the inlet concentration of pollutants. The operation adjustment was also an effective method to increase the energy efficiency. For example, the operation adjustment of slurry circulation pumps could promote the energy-saving operation of WFGD system. Implication Statement The application of pollutant abatement technologies increases the internal energy consumption of the power plant, which will lead to an increase of power generation costs. The real-time energy consumption of the different pollutant abatement systems in a typical power unit is analyzed based on the dynamic operating data. Further, the influence of different operating parameters on the operating power of the system and the possible energy-saving potential are analyzed.

  9. An improved AVC strategy applied in distributed wind power system

    Science.gov (United States)

    Zhao, Y. N.; Liu, Q. H.; Song, S. Y.; Mao, W.

    2016-08-01

    Traditional AVC strategy is mainly used in wind farm and only concerns about grid connection point, which is not suitable for distributed wind power system. Therefore, this paper comes up with an improved AVC strategy applied in distributed wind power system. The strategy takes all nodes of distribution network into consideration and chooses the node having the most serious voltage deviation as control point to calculate the reactive power reference. In addition, distribution principles can be divided into two conditions: when wind generators access to network on single node, the reactive power reference is distributed according to reactive power capacity; when wind generators access to network on multi-node, the reference is distributed according to sensitivity. Simulation results show the correctness and reliability of the strategy. Compared with traditional control strategy, the strategy described in this paper can make full use of generators reactive power output ability according to the distribution network voltage condition and improve the distribution network voltage level effectively.

  10. Alternative evacuation strategies for nuclear power accidents

    International Nuclear Information System (INIS)

    Hammond, Gregory D.; Bier, Vicki M.

    2015-01-01

    In the U.S., current protective-action strategies to safeguard the public following a nuclear power accident have remained largely unchanged since their implementation in the early 1980s. In the past thirty years, new technologies have been introduced, allowing faster computations, better modeling of predicted radiological consequences, and improved accident mapping using geographic information systems (GIS). Utilizing these new technologies, we evaluate the efficacy of alternative strategies, called adaptive protective action zones (APAZs), that use site-specific and event-specific data to dynamically determine evacuation boundaries with simple heuristics in order to better inform protective action decisions (rather than relying on pre-event regulatory bright lines). Several candidate APAZs were developed and then compared to the Nuclear Regulatory Commission’s keyhole evacuation strategy (and full evacuation of the emergency planning zone). Two of the APAZs were better on average than existing NRC strategies at reducing either the radiological exposure, the population evacuated, or both. These APAZs are especially effective for larger radioactive plumes and at high population sites; one of them is better at reducing radiation exposure, while the other is better at reducing the size of the population evacuated. - Highlights: • Developed framework to compare nuclear power accident evacuation strategies. • Evacuation strategies were compared on basis of radiological and evacuation risk. • Current strategies are adequate for smaller scale nuclear power accidents. • New strategies reduced radiation exposure and evacuation size for larger accidents

  11. Energy Saving Scheme Based On Traffic Forwarding For Optical Fiber Access Networks

    DEFF Research Database (Denmark)

    Lopez, G. Arturo Rodes; Estaran Tolosa, Jose Manuel; Vegas Olmos, Juan José

    2013-01-01

    We report on an energy saving block that regroups and powers off OLTs during low traffic periods, resulting in energy savings up to 87,5% in the central office of optical access networks.......We report on an energy saving block that regroups and powers off OLTs during low traffic periods, resulting in energy savings up to 87,5% in the central office of optical access networks....

  12. Heavy Traffic Feasible Hybrid Intracycle and Cyclic Sleep for Power Saving in 10G-EPON

    Directory of Open Access Journals (Sweden)

    Xintian Hu

    2014-01-01

    Full Text Available Energy consumption in optical access networks costs carriers substantial operational expense (OPEX every year and is one of contributing factors for the global warming. To reduce energy consumption in the 10-gigabit Ethernet passive optical network (10G-EPON, a hybrid intracycle and cyclic sleep mechanism is proposed in this paper. Under heavy traffic load, optical network units (ONUs can utilize short idle slots within each scheduling cycle to enter intracycle sleep without postponing data transmission. In this way, energy conservation is achieved even under heavy traffic load with quality of service (QoS guarantee. Under light traffic load, ONUs perform long cyclic sleep for several scheduling cycles. The adoption of cyclic sleep instead of intracycle sleep under light traffic load can reduce unnecessary frequent transitions between sleep and full active work caused by using intracycle sleep. Further, the Markov chain of the proposed mechanism is established. The performances of the proposed mechanism and existing approaches are analyzed quantitatively based on the chain. For the proposed mechanism, power saving ability with QoS guarantee even under heavy traffic and better power saving performance than existing approaches are verified by the quantitative analysis. Moreover, simulations validate the above conclusions based on the chain.

  13. SAVING BEHAVIOUR AND DETERMINANTS OF SAVING MOBILIZATION BY RURAL FINANCIAL CO-OPERATORS IN TIGRAI REGION, ETHIOPIA

    Directory of Open Access Journals (Sweden)

    Sebhatu Kifle Tesfamariam

    2012-01-01

    Full Text Available This paper identified and examined saving behaviour and determinants of saving mobiliza-tion by the rural co-operators in Southern Tigrai Ethiopia. The input for the study was ob-tained from randomly selected 120 rural household savers from six purposively selected ru-ral savings and credit cooperatives. The result of the study using least squares method showed that savings mobilized is determined by household annual income, amount of loan borrowed and year of member stay in the cooperative. These factors therefore have to be considered in designing strategies aimed at improving the saving mobilization of coopera-tive members in the study area. Besides, economically feasible cooperative societies in the region should be encouraged among the rural households by supporting them with revolv-ing funds as they are more effective and efficient in mobilizing rural savings and provide collateral plus guarantor-based loans with low default rate. This will enable them to boost up their production output and increase their savings thereby stimulating the rural economy.

  14. Effect of Marketing Strategy on Customer Loyalty Bajapuik Savings at PT. BPR Berok Gunung Pangilun Padangn

    Directory of Open Access Journals (Sweden)

    H. Heryanto

    2011-06-01

    Full Text Available This study attempts to look and see if the marketing strategy of product, price, and location and upon promotion will affect customer loyalty bajapuik savings on PT.BPR Berok Gunung Pangilun Padang. This study uses primary data, where the object under study here is PT. BPR Berok Gunung Pangilun Padang. Total sample was 100 people taken from the 5750 population of people who gathered from 3 cash offices and 1 center office at PT. BPR Berok Gunung Pangilun Padang. The approach used to test the hypothesis of this study is multiple regression analysis, t-test f-test and anova. From the results showed that a significant difference between variables Marketing Strategies with Customer Loyalty.

  15. MARKETING STRATEGY OF STUDENTS PERCEPTION TO SAVE IN SYARIAH BANKING AT SRIWIJAYA UNIVERSITY PALEMBANG (Strategi Pemasaran Terhadap Persepsi Mahasiswa Untuk Menabung Di Bank Syariah Pada Universitas Sriwijaya Palembang

    Directory of Open Access Journals (Sweden)

    Delta Khairunnisa

    2014-08-01

    Full Text Available This research entitled Marketing Strategy of Students Perception to save in Syariah Banking at Sriwijaya University Palembang was aimed at investigating and analyzing whether mixed marketing variables altogether affected students decision on whether or not to save at Syariah Banking, and to investigate which factors that were the most dominant. This research was a causal research which used two groups of variables. They were independent variables consisting of product (X1, price (X2, place (X3, promotion (X4, people (X5, process (X6, and customer service (X7. The dependent variables was students perception (Y toward to service of syariah banking which consisted of expectation, motivation, and learning. To measure relationship among variables, multiple regression statistical analysis was used. Based on the results of regression analysis, all mixed marketing variables altogether affected students’ decision making in whether or not saving at syariah banking. Partially, variables of product, promotion and customer service had dominant affects toward students’ decision on saving at syariah banking.

  16. A hybrid method of incorporating extended priority list into equal incremental principle for energy-saving generation dispatch of thermal power systems

    International Nuclear Information System (INIS)

    Cheng, Chuntian; Li, Shushan; Li, Gang

    2014-01-01

    The energy-saving generation dispatch (ESGD) policy released by Chinese Government in 2007 is a new code for optimally dispatching electric power generation portfolio in the country with the dual objectives of improving energy efficiency and reducing environmental pollution. The ESGD is substantially different from the competitive market in the developed economies, the traditional economic dispatching or the rational dispatching principle implemented in China prior to the new policy. This paper develops a hybrid method that integrates the extended priority list (EPL), the equal incremental principle (EIP) and a heuristic method to optimize daily generation schedules under ESGD. The EPL is presented to search desirable units set that satisfies the complicated duration period requirements based on thermal unit generation priority list. The EIP is developed to allocate load among the committed units within the combined set. A heuristic method is proposed to deal with inequality constraints, which usually result in difficulty for power allocation, and used to improve these results. The algorithm has been embedded into a newly developed decision support system that is currently being used by operators of the Guizhou Province Power Grid to make day-ahead quarter-hourly generation schedules. - Highlights: • Electric power industry is one of key and important fields for energy conservation and emission reduction in China. • The energy-saving generation dispatch policy was released by Chinese government in 2007. • A Hybrid algorithm for energy-saving generation dispatch scheduling of thermal power system is presented. • The algorithm has been embedded into a newly developed decision support system

  17. Simplified reactive power management strategy for complex power grids under stochastic operation and incomplete information

    International Nuclear Information System (INIS)

    Vlachogiannis, John G.

    2009-01-01

    In the current released energy market, the large-scale complex transmission networks and the distribution ones with dispersed energy sources and 'intelligent' components operate under uncertainties, stochastic and prior incomplete information. A safe and reliable operation of such complex power grids is a major issue for system operators. Under these circumstances an online reactive power management strategy with minimum risk concerning all uncertain and stochastic parameters is proposed. Therefore, new concepts such as reactive power-weighted node-to-node linking and reactive power control capability are introduced. A distributed and interconnected stochastic learning automata system is implemented to manage, in a unified and unique way, the reactive power in complex power grids with stochastic reactive power demand and detect the vulnerable part. The proposed simplified strategy can also consider more stochastic aspects such as variable grid's topology. Results of the proposed strategy obtained on the networks of IEEE 30-bus and IEEE 118-bus systems demonstrate the effectiveness of the proposed strategy.

  18. 76 FR 20459 - Savings and Loan Holding Company Application

    Science.gov (United States)

    2011-04-12

    ... DEPARTMENT OF THE TREASURY Office of Thrift Supervision Savings and Loan Holding Company... concerning the following information collection. Title of Proposal: Savings and Loan Holding Company... officer of a savings and loan holding company, or any individual who owns, controls, or holds with power...

  19. Cogeneration an opportunity for industrial energy saving

    International Nuclear Information System (INIS)

    Pasha, R.A.; Butt, Z.S.

    2011-01-01

    This paper is about the cogeneration from industrial energy savings opportunities perspective. The energy crisis in these days forces industry to find ways to cope with critical situation. There are several energy savings options which if properly planned and implemented would be beneficial both for industry and community. One way of energy saving is Cogeneration i.e. Combined Heat and Power. The paper will review the basic methods, types and then discuss the suitability of these options for specific industry. It has been identified that generally process industry can get benefits of energy savings. (author)

  20. Iran's Sea Power Strategy: Goals and Evolution

    National Research Council Canada - National Science Library

    Walker, John

    1997-01-01

    This thesis examines the intent of Iran's sea power strategy using a multipart analysis including a historical review of the transition of Iran's naval power through the Iranian Revolution, Iran-Iraq...

  1. Energy saving and emission reduction of China's urban district heating

    International Nuclear Information System (INIS)

    Chen, Xia; Wang, Li; Tong, Lige; Sun, Shufeng; Yue, Xianfang; Yin, Shaowu; Zheng, Lifang

    2013-01-01

    China's carbon dioxide (CO 2 ) emission ranks highest in the world. China is committed to reduce its CO 2 emission by 40% to 45% from the 2005 levels by 2020. To fulfill the target, China's CO 2 emission reduction must exceed 6995 million tons. Energy consumption and CO 2 emission of China's urban district heating (UDH) are increasing. The current policy implemented to improve UDH focuses on replacing coal with natural gas to reduce energy consumption and CO 2 emission to some extent. This paper proposes that heat pump heating (HPH) could serve as a replacement for UDH to help realize energy-saving and emission-reduction goals to a greater extent. The paper also analyzes the impact of this replacement on the heating and power generation sectors. The results show that replacing coal-based UDH with HPH decreases energy consumption and CO 2 emission by 43% in the heating sector. In the power generation sector, the efficiency of power generation at the valley electricity time increases by 0.512%, and the ratio of peak–valley difference decreases by 16.5%. The decreases in CO 2 emission from the heating and power generation sectors cumulatively account for 5.55% of China's total CO 2 emission reduction target in 2020. - Highlights: ► Replacing urban district heating with heat pump heating. ► Impact of heat pump heating on heating and power generation sectors. ► Potential of energy saving and emission reduction for heat pump heating. ► China should adjust current urban heating strategy

  2. Energy Saving and Efficient Energy Use By Power Electronic Systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Wang, Huai; Davari, Pooya

    2017-01-01

    In the development of the modern society, one of the key factors is to save energy in order to become more independent of other energy resources. Two important approaches can be taken—one is to change behavior and thereby save energy—the second one is to develop new technology which is able to sa...

  3. Power supply strategy in Lithuania

    International Nuclear Information System (INIS)

    Galinis, A.

    2000-01-01

    Nuclear power plant produces about 80% of electricity in Lithuania. However, national energy strategy as a result of comprehensive assessment of technical, economic and political factors foresees closure of its first unit by 2005. Future fate of the second unit will be defined later in 2004 . Electricity demand requirements will be covered by other modernised power plants burning fossil fuel. This may create some environmental problems, especially if unit 2 would be closed. Earlier closure of the nuclear power plant is a great economical burden not only for the power sector but also to the whole national economy. This requires substantial technical and financial support from EU and other developed countries. (author)

  4. Specification of data centre power management strategies

    NARCIS (Netherlands)

    Postema, Björn F.; Haverkort, Boudewijn R.

    2017-01-01

    In recent work, we proposed a flexible simulation framework (using AnyLogic) for the trade-off. analysis of power and performance in data centres. We now extend this framework with a versatile module to study the effect of advanced power management strategies based on both power and performance

  5. Integrated power-saving motor for power-demands of less than one kilowatt; Integral-Sparmotor im Leistungsbereich < 1 kW

    Energy Technology Data Exchange (ETDEWEB)

    Lindegger, M.; Kreuzer, H.H.; Lischer, G.

    2005-10-15

    This annual report for the Swiss Federal Office of Energy (SFOE) takes a look at the results of the second phase of a project concerning the development of integrated energy-saving electrical motors in the power range less than one kilowatt. The search for industrial partners is commented on and the publishing of an initial functional prototype on the Internet is mentioned. Participation at various fairs and the publication of articles in the technical press are mentioned. Further work on the motor is described, as is development work done on the drive electronics and the associated software. Further work planned is described.

  6. A Novel Power-Saving Transmission Scheme for Multiple-Component-Carrier Cellular Systems

    Directory of Open Access Journals (Sweden)

    Yao-Liang Chung

    2016-04-01

    Full Text Available As mobile data traffic levels have increased exponentially, resulting in rising energy costs in recent years, the demand for and development of green communication technologies has resulted in various energy-saving designs for cellular systems. At the same time, recent technological advances have allowed multiple component carriers (CCs to be simultaneously utilized in a base station (BS, a development that has made the energy consumption of BSs a matter of increasing concern. To help address this concern, herein we propose a novel scheme aimed at efficiently minimizing the power consumption of BS transceivers during transmission, while still ensuring good service quality and fairness for users. Specifically, the scheme utilizes the dynamic activation/deactivation of CCs during data transmission to increase power usage efficiency. To test its effectiveness, the proposed scheme was applied to a model consisting of a BS with orthogonal frequency division multiple access-based CCs in a downlink transmission environment. The results indicated that, given periods of relatively light traffic loads, the total power consumption of the proposed scheme is significantly lower than that of schemes in which all the CCs of a BS are constantly activated, suggesting the scheme’s potential for reducing both energy costs and carbon dioxide emissions.

  7. Replacement or additional purchase: The impact of energy-efficient appliances on household electricity saving under public pressures

    International Nuclear Information System (INIS)

    Mizobuchi, Kenichi; Takeuchi, Kenji

    2016-01-01

    This study examined the influence of additional and replacement purchases of energy-efficient air-conditioners on power savings. We used a questionnaire survey and measured electricity use data from 339 Japanese households, collected from two city areas with different level of government-requested electricity-saving rates, namely, Osaka (10%) and Matsuyama (5%). The main findings of our study are as follows: (1) Households that purchased energy-efficient air-conditioners saved more electricity than those that did not. (2) “Additional-purchase households” showed significant energy savings, whereas “replacement households” did not. The rebound effect may negate the energy-saving effects of a new air-conditioner. (3) Altruistic attitude is associated with more active participation in power saving. (4) Households in Osaka saved more electricity than those in Matsuyama, probably because the government call to save electricity was more forceful. - Highlights: •Energy efficient air conditioner purchases affect household power savings. •Additional air conditioner purchase led to significant energy savings. •Replacement units did not produce more savings than non-purchase. • “Electricity conservation directives” amount had a significant power-saving effect. •Altruistic households were more likely to cooperate with power-saving requests.

  8. Bidding Strategy of Virtual Power Plant with Energy Storage Power Station and Photovoltaic and Wind Power

    Directory of Open Access Journals (Sweden)

    Zhongfu Tan

    2018-01-01

    Full Text Available For the virtual power plants containing energy storage power stations and photovoltaic and wind power, the output of PV and wind power is uncertain and virtual power plants must consider this uncertainty when they participate in the auction in the electricity market. In this context, this paper studies the bidding strategy of the virtual power plant with photovoltaic and wind power. Assuming that the upper and lower limits of the combined output of photovoltaic and wind power are stochastically variable, the fluctuation range of the day-ahead energy market and capacity price is stochastically variable. If the capacity of the storage station is large enough to stabilize the fluctuation of the output of the wind and photovoltaic power, virtual power plants can participate in the electricity market bidding. This paper constructs a robust optimization model of virtual power plant bidding strategy in the electricity market, which considers the cost of charge and discharge of energy storage power station and transmission congestion. The model proposed in this paper is solved by CPLEX; the example results show that the model is reasonable and the method is valid.

  9. Generating optimized stochastic power management strategies for electric car components

    Energy Technology Data Exchange (ETDEWEB)

    Fruth, Matthias [TraceTronic GmbH, Dresden (Germany); Bastian, Steve [Technische Univ. Dresden (Germany)

    2012-11-01

    With the increasing prevalence of electric vehicles, reducing the power consumption of car components becomes a necessity. For the example of a novel traffic-light assistance system, which makes speed recommendations based on the expected length of red-light phases, power-management strategies are used to control under which conditions radio communication, positioning systems and other components are switched to low-power (e.g. sleep) or high-power (e.g. idle/busy) states. We apply dynamic power management, an optimization technique well-known from other domains, in order to compute energy-optimal power-management strategies, sometimes resulting in these strategies being stochastic. On the example of the traffic-light assistant, we present a MATLAB/Simulink-implemented framework for the generation, simulation and formal analysis of optimized power-management strategies, which is based on this technique. We study capabilities and limitations of this approach and sketch further applications in the automotive domain. (orig.)

  10. Optimal generator bidding strategies for power and ancillary services

    Science.gov (United States)

    Morinec, Allen G.

    As the electric power industry transitions to a deregulated market, power transactions are made upon price rather than cost. Generator companies are interested in maximizing their profits rather than overall system efficiency. A method to equitably compensate generation providers for real power, and ancillary services such as reactive power and spinning reserve, will ensure a competitive market with an adequate number of suppliers. Optimizing the generation product mix during bidding is necessary to maximize a generator company's profits. The objective of this research work is to determine and formulate appropriate optimal bidding strategies for a generation company in both the energy and ancillary services markets. These strategies should incorporate the capability curves of their generators as constraints to define the optimal product mix and price offered in the day-ahead and real time spot markets. In order to achieve such a goal, a two-player model was composed to simulate market auctions for power generation. A dynamic game methodology was developed to identify Nash Equilibria and Mixed-Strategy Nash Equilibria solutions as optimal generation bidding strategies for two-player non-cooperative variable-sum matrix games with incomplete information. These games integrated the generation product mix of real power, reactive power, and spinning reserve with the generators's capability curves as constraints. The research includes simulations of market auctions, where strategies were tested for generators with different unit constraints, costs, types of competitors, strategies, and demand levels. Studies on the capability of large hydrogen cooled synchronous generators were utilized to derive useful equations that define the exact shape of the capability curve from the intersections of the arcs defined by the centers and radial vectors of the rotor, stator, and steady-state stability limits. The available reactive reserve and spinning reserve were calculated given a

  11. Brand Strategy and Japan’s Soft Power

    Institute of Scientific and Technical Information of China (English)

    Xing; YAN

    2015-01-01

    The 21st century is the time of brand strategy showing its position and importance in operation of enterprises.Rapid rise of the brand strategy in operation and management of enterprises has profound social and operation background.The development process of brand strategy also reflects evolution of market economy.A country’s cultural influence power depends on its brand equity.An essential task of brand promotion for a county is to narrow the gap between original image and target image,change the past or one-sided image of the public to products of the country,and implement effective communication and propaganda with the aid of related resource system in the country’s soft power,and accept new excellent image.Fundamentally,lifting national soft power is to set up distinct and charming national brand or national image.The influence power with culture and communication as core is the direct manifestation of a country’s core competitiveness.Brand is an outstanding feature of a country’s strength.Brand stretching can promote liftoff of national economy.In expanding international market,famous brands will play a more and more important role.

  12. Optimal energy management strategy for battery powered electric vehicles

    International Nuclear Information System (INIS)

    Xi, Jiaqi; Li, Mian; Xu, Min

    2014-01-01

    Highlights: • The power usage for battery-powered electrical vehicles with in-wheel motors is maximized. • The battery and motor dynamics are examined emphasized on the power conversion and utilization. • The optimal control strategy is derived and verified by simulations. • An analytic expression of the optimal operating point is obtained. - Abstract: Due to limited energy density of batteries, energy management has always played a critical role in improving the overall energy efficiency of electric vehicles. In this paper, a key issue within the energy management problem will be carefully tackled, i.e., maximizing the power usage of batteries for battery-powered electrical vehicles with in-wheel motors. To this end, the battery and motor dynamics will be thoroughly examined with particular emphasis on the power conversion and power utilization. The optimal control strategy will then be derived based on the analysis. One significant contribution of this work is that an analytic expression for the optimal operating point in terms of the component and environment parameters can be obtained. Owing to this finding, the derived control strategy is also rendered a simple structure for real-time implementation. Simulation results demonstrate that the proposed strategy works both adaptively and robustly under different driving scenarios

  13. Heat savings in energy systems with substantial distributed generation

    DEFF Research Database (Denmark)

    Østergaard, PA

    2003-01-01

    In Denmark, the integration of wind power is affected by a large amount of cogeneration of heat and power. With ancillary services supplied by large-scale condensation and combined heat and power (CHP) plants, a certain degree of large-scale generation is required regardless of momentary wind input......, if a certain production is required regardless of whether over-all electricity generation is sufficient. This article analyses this and although heat savings do have a negative impact on the amount of wind power the system may integrate a given moment in certain cases, associated fuel savings are notable...

  14. Saving electricity in a hurry - update 2011

    Energy Technology Data Exchange (ETDEWEB)

    Pasquier, Sara Bryan

    2011-06-15

    As demonstrated by the March 2011 earthquake and tsunami-triggered blackouts in Japan, electricity shortfalls can happen anytime and anywhere. Countries can minimise the negative economic, social and environmental impacts of such electricity shortfalls by developing emergency energy-saving strategies before a crisis occurs. This new IEA report highlights preliminary findings and conclusions from electricity shortfalls in Japan, the United States, New Zealand, South Africa and Chile. It draws on recent analysis to: reinforce well-established guidelines on diagnosing electricity shortfalls, identifying energy-saving opportunities and selecting a package of energy-saving measures; and highlight proven practice for implementing emergency energy-saving programmes. This paper will be valuable to government, academic, private-sector and civil-society stakeholders who inform, develop and implement electricity policy in general, and emergency energy-saving programmes in particular.

  15. Modeling and simulation to determine the potential energy savings by implementing cold thermal energy storage system in office buildings

    International Nuclear Information System (INIS)

    Rismanchi, B.; Saidur, R.; Masjuki, H.H.; Mahlia, T.M.I.

    2013-01-01

    Highlights: • Simulating the CTES system behavior based on Malaysian climate. • Almost 65% of power is used for cooling for cooling the office buildings, every day. • The baseline shows an acceptable match with real data from the fieldwork. • Overall, the energy used for full load storage is much than the conventional system. • The load levelling storage strategy has 3.7% lower energy demand. - Abstract: In Malaysia, air conditioning (AC) systems are considered as the major energy consumers in office buildings with almost 57% share. During the past decade, cold thermal energy storage (CTES) systems have been widely used for their significant economic benefits. However, there were always doubts about their energy saving possibilities. The main objective of the present work is to develop a computer model to determine the potential energy savings of implementing CTES systems in Malaysia. A case study building has been selected to determine the energy consumption pattern of an office building. In the first step the building baseline model was developed and validated with the recorded data from the fieldwork. Once the simulation results reach an acceptable accuracy, different CTES system configuration was added to the model to predict their energy consumption pattern. It was found that the overall energy used by the full load storage strategy is considerably more than the conventional system. However, by applying the load leveling storage strategy, and considering its benefits to reduce the air handling unit size and reducing the pumping power, the overall energy usage was almost 4% lower than the non-storage system. Although utilizing CTES systems cannot reduce the total energy consumption considerably, but it has several outstanding benefits such as cost saving, bringing balance in the grid system, reducing the overall fuel consumption in the power plants and consequently reducing to total carbon footprint

  16. Dyadic Power Profiles: Power-Contingent Strategies for Value Creation in Negotiation

    Science.gov (United States)

    Olekalns, Mara; Smith, Philip Leigh

    2013-01-01

    Using a simulated employment negotiation, we tested the conditional relationships among dyadic power profiles (symmetric high, symmetric low, and asymmetric), the choice and sequencing of strategies, and value creation. We showed that negotiators in symmetric high, symmetric low, and asymmetric power dyads took distinctly different paths to value…

  17. Power Generation Strategy Development in Croatia

    International Nuclear Information System (INIS)

    Curkovic, A.; Androcec, I.; Tarnik, T.

    2010-01-01

    Electricity generation as an economic sector contributes to the national GDP through increasing investments and exports. In the period from 2000 to 2008 the annual growth rate of final electricity demand was 3,8% which was higher than for any other energy form. Almost 1200 MW of thermal power plants will go out of system due to lifetime (more than 30 years). Energy Strategy is a basic document of the Energy Act with the purpose to define energy policy and future plans for energy development of the Republic of Croatia till 2020. Based on the adopted strategy the Government will create the Energy Strategy Implementation Programme for the four-year period. Croatian's energy development should be based on best available technologies as well as on energy-related, economic and environmental assessment of all available energy options. Energy strategy of Croatia (NN 130/09) puts up next goals: 300 MW hydro power plants (bigger than 10 MW), 1200 MW gas-fired thermal power plants (including 300 MW of cogeneration), 1200 MW of coal-fired thermal power plants, and 35% of renewable (including hydro). The market, i.e. a competitive generation, is the driving force in the construction of new power plants. The main stimulus for the construction is the possibility of definite return of invested capital as well as earning of reasonable profit for investors. Choose of location, environmental impact and competitiveness are main criteria for decision making. Technological and financial terms of new power plant is under influence of the law of supply and demand, so short marginal costs are in the first view - power plant life is at least 30 years - how to deal with this conditions, who will invest in long-term projects with condition of short pay-back period. Climate change and greenhouse gas emissions have become a priority development issue. The main challenge is a long-term development of economy with decreased emission of carbon dioxide. Kyoto protocol obligations, Copenhagen Accord

  18. Predictive Maintenance (PdM) Centralization for Significant Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Dale

    2010-09-15

    Cost effective predictive maintenance (PdM) technologies and basic energy calculations can mine energy savings form processes or maintenance activities. Centralizing and packaging this information correctly empowers facility maintenance and reliability professionals to build financial justification and support for strategies and personnel to weather global economic downturns and competition. Attendees will learn how to: Systematically build a 'pilot project' for applying PdM and tracking systems; Break down a typical electrical bill to calculate energy savings; Use return on investment (ROI) calculations to identify the best and highest value options, strategies and tips for substantiating your energy reduction maintenance strategies.

  19. Strategies for energy saving in warm climate dwellings; Estrategias de ahorro de energia para viviendas en clima calido

    Energy Technology Data Exchange (ETDEWEB)

    Pilatowsky, I [Centro de Investigacion en Energia, Universidad Nacional Autonoma de Mexico (Mexico); Ramos Niembro, Gaudencio [Comision Nacional para el Ahorro de Energia -CONAE (Mexico); Morillon, David [Instituto de Ingenieria, Universidad Nacional Autonoma de Mexico (Mexico); Oskam, A. [Centro de Fisica Aplicada y Tecnologia Avanzada, Universidad Nacional Autonoma de Mexico (Mexico)

    2008-04-15

    The domestic sector consumes almost one quarter of the national electrical energy. In order to reduce in an important manner the power consumption in dwellings there is an integral alternative based on three elements: the bio-climatic design, the saving and efficient use of the energy in equipment and apparatuses, and the use of centralized air conditioning systems. Besides saving the electrical and thermal power consumption, with this scheme, comfort conditions are pretended to be reached in dwellings and, contributing at the same time, to the diminution of polluting emissions. [Spanish] El sector domestico consume casi una cuarta parte de la energia electrica nacional. Con objeto de reducir de manera importante el consumo de energia en las viviendas, se presenta una alternativa integral, basada en tres elementos: el diseno bioclimatico, el ahorro y uso eficiente de la energia en equipos y aparatos, y la utilizacion de sistemas de climatizacion centralizados. Ademas del ahorro en el consumo de energia electrica y termica, con este esquema se pretende alcanzar condiciones de confort en las viviendas y, al mismo tiempo, contribuir a la disminucion de emisiones contaminantes.

  20. Strategies for growth of hydro electric power

    International Nuclear Information System (INIS)

    Khera, D.V.

    1998-01-01

    Hydro power on account of its several inherent advantages has a key role to play in the development of long term energy strategies based on diversified and balance use of natural national resources. Our country is fortunate to be endowed with large hydro-electric potential. It is estimated that the hydro potential while fully developed may yield to an installed capacity of 1,50,000 MW. An attempt has been made in this paper to examine and analyse the status and trend of hydro power development, need for accelerated development of hydro power, myths about hydro electric projects, principal causes responsible for scaling down of hydro share in the total installed capacity and strategies which could restore optimum hydro thermal mix. (author)

  1. Fuel Savings Potential from Future In-motion Wireless Power Transfer (WPT); NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    Burton, E.; Wang, L.; Gonder, J.; Brooker, A.; Konan, A.

    2015-02-10

    This presentation discusses the fuel savings potential from future in-motion wireless power transfer. There is an extensive overlap in road usage apparent across regional vehicle population, which occurs primarily on high-capacity roads--1% of roads are used for 25% of the vehicle miles traveled. Interstates and highways make up between 2.5% and 4% of the total roads within the Consolidated Statistical Areas (CSAs), which represent groupings of metropolitan and/or micropolitan statistical areas. Mileage traveled on the interstates and highways ranges from 54% in California to 24% in Chicago. Road electrification could remove range restrictions of electric vehicles and increase the fuel savings of PHEVs or HEVs if implemented on a large scale. If 1% of the road miles within a geographic area are electrified, 25% of the fuel used by a 'fleet' of vehicles enabled with the technology could be displaced.

  2. Information is Power, Using Information is Powerful: Components of a National Information Strategy

    National Research Council Canada - National Science Library

    Parks, Wayne

    2004-01-01

    .... The current National Security Strategy addresses diplomatic, economic, and military power, but does not provide any substantial effort to instill an information campaign into the overall national strategy...

  3. Delta Power Control Strategy for Multistring Grid-Connected PV Inverters

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Blaabjerg, Frede

    2017-01-01

    , is required for grid support (e.g., during frequency deviation). In this paper, a cost-effective solution to realize delta power control (DPC) for grid-connected PV systems is presented, where the multistring PV inverter configuration is adopted. This control strategy is a combination of maximum power point...... tracking (MPPT) and constant power generation (CPG) modes. In this control scheme, one PV string operating in the MPPT mode estimates the available power, whereas the other PV strings regulate the total PV power by the CPG control strategy in such a way that the delta power constraint for the entire PV...... system is achieved. Simulations and experiments have been performed on a 3-kW single-phase grid-connected PV system. The results have confirmed the effectiveness of the proposed DPC strategy, where the power reserve according to the delta power constraint is achieved under several operating conditions....

  4. Taxation and the household saving rate: evidence from OECD countries

    Directory of Open Access Journals (Sweden)

    Vito Tanzi

    2000-03-01

    Full Text Available This paper analyzes anew the relationship between taxation and the household saving rate. On the basis of standard savings and tax revenue data from a sample of OECD countries, it provides compelling empirical evidence of a powerful impact of taxes on household savings. In particular, income taxes are shown to affect negatively the household saving rate much more than consumption taxes.

  5. Energy management strategies for vehicle power nets

    NARCIS (Netherlands)

    Koot, M.W.T.; Jager, de A.G.; Kessels, J.T.B.A.; Heemels, W.P.M.H.; Bosch, van den P.P.J.

    2004-01-01

    In the near future a significant increase in electric power consumption in vehicles is to be expected. To limit the associated increase in fuel consumption and exhaust emissions, smart strategies for the generation, storage/retrieval, distribution, and consumption of the electric power can be used.

  6. Energy Saving in Data Processing and Communication Systems

    Directory of Open Access Journals (Sweden)

    Giuseppe Iazeolla

    2014-01-01

    Full Text Available The power management of ICT systems, that is, data processing (Dp and telecommunication (Tlc systems, is becoming a relevant problem in economical terms. Dp systems totalize millions of servers and associated subsystems (processors, monitors, storage devices, etc. all over the world that need to be electrically powered. Dp systems are also used in the government of Tlc systems, which, besides requiring Dp electrical power, also require Tlc-specific power, both for mobile networks (with their cell-phone towers and associated subsystems: base stations, subscriber stations, switching nodes, etc. and for wired networks (with their routers, gateways, switches, etc.. ICT research is thus expected to investigate into methods to reduce Dp- and Tlc-specific power consumption. However, saving power may turn into waste of performance, in other words, into waste of ICT quality of service (QoS. This paper investigates the Dp and Tlc power management policies that look at compromises between power saving and QoS.

  7. An extra power saving scheme for prolonging lifetime of mobile handset in the 4G mobile networks.

    Science.gov (United States)

    Chen, Jenhui; Tarn, Woei-Hwa; Lee, Jiann-Der

    2014-01-01

    In the fourth generation or next generation networks, services of non-real-time variable bit rate (NRT-VBR) and best effort (BE) will dominate over 85% of the total traffic in the networks. In this paper, we study the power saving mechanism of NRT-VBR and BE services for mobile handsets (MHs) to prolong their battery lifetime (i.e., the sustained operation duration) in the fourth generation networks. Because the priority of NRT-VBR and BE is lower than that of real-time VBR (RT-VBR) or guaranteed bit rate (GBR) services, we investigate an extended sleep mode for lower priority services (e.g., NRT-VBR and BE) in an MH to conserve the energy. The extended sleep mode is used when the MH wakes up from the sleep mode but it cannot obtain the bandwidth from base station (BS). The proposed mechanism, named extra power saving scheme (EPSS), uses the M/M/k/k Markovian queuing model to estimate the extended sleep duration to let MHs conserve their battery energy when the networks traffic is congested. To study the performance of EPSS, an accurate analysis model of energy is presented and validated by taking a series of simulations. Numerical experiments show that EPSS can achieve 43% extra energy conservation at most when downlink resource is saturated. We conclude that the energy of MHs can be conserved further by applying EPSS when the traffic load is saturated. The effect of energy saving becomes more obvious when the portion of NRT-VBR and BE services is greater than that of RT-VBR and GBR services.

  8. Riding the Electricity Market as an Energy Management Strategy: Savings from Real-Time Pricing

    Energy Technology Data Exchange (ETDEWEB)

    Chiles, Thomas [U.S. General Services Administration, Washington, D.C. (United States); Shutika, Kenneth [U.S. General Services Administration, Washington, D.C. (United States); Coleman, Philip [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2018-03-13

    Dynamic pricing of electricity, in which retail prices facing customers are responsive to changes in the underlying wholesale markets, represents a step towards economic efficiency in that customers get exposed to some or all of the costs facing wholesale market players. But what do customers who opt for this greater exposure – available in the roughly 15 “de-regulated” states, as well as, to some extent, from some regulated utilities – get in return for their risks? The U.S. General Services Administration (GSA) took a retrospective eight-year look at what the savings would have been had they let the loads for which they purchase electricity in the Washington, DC area buy electricity on the real-time pricing (RTP) market – the dynamic pricing option with the highest risk – as opposed to the strategy they chose in actuality, which was fixing flat prices with 3rd-party providers. We found that opting for RTP for the eight years of the study (2005 through 2012) would have resulted in 17% savings, or almost a quarter of a billion dollars, relative to GSA’s actual prices from the 3rd-party suppliers. This is particularly astonishing given that GSA appeared to have timed the market well during the study period, consistently beating the standard offer products provided by the distribution utilities. The issue of budgetary predictability poses an obstacle for customers (especially government ones) considering RTP and, to a lesser extent, other dynamic pricing options. Indeed, GSA would have lost money with RTP in two of the eight years, one of them substantially. But the magnitude of the savings is indisputably compelling and, even if it may be somewhat aberrational due to high congestion in the DC market, begs consideration by large electricity users currently paying to “lock in” fixed flat prices.

  9. Global power: Markets and strategies

    International Nuclear Information System (INIS)

    Poirer, J.L.

    1998-01-01

    The author will first present an updated view of the global power market activity, including opportunities in power generation, transmission and distribution. This will include a review of the trends in closings and transaction flowed by type of activity and geographic area. Estimates will be based on Hagler Bailly's comprehensive database on global power transactions and project announcements. The firm has also worked with dozens of global power companies since 1990. Second, the author will review trends in terms of regulatory changes, project cost trends, developers' project experiences, and financing issues. This systematic review will be the foundation for projection of future market activity (e.g., number of closing by type of project through 2000). A forecast of future greenfield and privatization activity will be provided and the key markets will be highlighted. Third, the author will present an updated view of the competition in the global power market (including the various types of competitors and changes in their respective market posture). Finally, the author will discuss the various types of strategies and business models that are followed by key global power players

  10. Active power control strategies for inverter-based distributed power generation adapted to grid-fault ride-through requirements

    NARCIS (Netherlands)

    Wang, F.; Duarte, J.L.; Hendrix, M.A.M.

    2009-01-01

    Distributed power generation is expected to deliver power into the grid without interruption during voltage dips. To improve system ride-through capabilities, a generalized active power control strategy is proposed for grid-interfacing inverters. Specifically, a current reference generation strategy

  11. Strategies for competitive nuclear power plants

    International Nuclear Information System (INIS)

    1999-11-01

    This technical publication on competitive strategies for nuclear power plants (NPPs) is part of an ongoing project on management of NPP operations in a competitive environment. The overall objective of this project is to assist the management of operating organizations and NPPs in identifying and implementing appropriate measures to remain competitive in a rapidly changing business environment. Other documents that have been written on this topic have focused on how the environment in which NPPs operate is changing. This report instead focuses on strategies and techniques that operating organization and NPP managers can use to succeed in this environment. Of particular note is ongoing OECD/NEA work to describe the environment for nuclear power in competitive electricity markets. The main objective of the OECD/NEA study is to review the impacts of increasing market competition on the nuclear power sectors in OECD Member countries. The OECD/NEA study is identifying various nuclear aspects which have to be considered in relation to the regulatory reform of the electricity sector in OECD Member States. The OECD/NEA work was co-ordinated with the development of this IAEA report; staff members from the two organizations participated in the development and review of the associated documents. Thus, the strategies and techniques identified in this report are consistent with the impacts of increasing market competition identified in the OECD/NEA study

  12. Priority Control Strategy of VSC-MTDC System for Integrating Wind Power

    Directory of Open Access Journals (Sweden)

    Wen-ning Yan

    2015-01-01

    Full Text Available For the obvious advantages in integrating wind power, multiterminal HVDC transmission system (VSC-MTDC is widely used. The priority control strategy is proposed in this paper considering the penetration rate of wind power for the AC grid. The strategy aims to solve the problems of power allocation and DC voltage control of the DC system. The main advantage of this strategy is that the demands for wind power of different areas can be satisfied and a power reference for the wind power trade can also be provided when wind farms transmit active power to several AC grids through the DC network. The objective is that power is well distributed according to the output power of wind farm with the demand of AC system and satisfactory control performance of DC voltage is obtained.

  13. Energy Saving by Chopping off Peak Demand Using Day Light

    Directory of Open Access Journals (Sweden)

    Ashok Kumar Maitra

    2011-08-01

    Full Text Available An artificial intelligent technique has been implemented in this research using real time datas to calculate how much energy can be chopped from peak load demand. The results are based on real time data that are taken from power delivering centers. These datas do reflect the present condition of power and a solution to those critical conditions during the peak period. These are done in such a way such that helps in judicious scheduling of load. The time based load scheduling has been done so as to understand the basic criteria for solving power crisis during morning peak and early evening peak. The sunray availability and percentage of load that will use day light saving (DLS technique has been taken into account in this work. The results shows that about 0.5% to 1% of load can be shedded off from the peak load period which otherwise is reduction of power. Thus it otherwise also means that an equivalent amount of energy is saved which amounts to a large saving of national money. This result is obtained on monthly and even daily basis. Thus this paper justifies DLS gives a new renewable technique to save energy.

  14. A novel evolutionary algorithm for dynamic economic dispatch with energy saving and emission reduction in power system integrated wind power

    International Nuclear Information System (INIS)

    Liao, Gwo-Ching

    2011-01-01

    An optimization algorithm is proposed in this paper to solve the economic dispatch problem that includes wind farm using the Chaotic Quantum Genetic Algorithm (CQGA). In addition to the detailed models of economic dispatch introduction and their associated constraints, the wind power effect is also included in this paper. The chaotic quantum genetic algorithm used to solve the economic dispatch process and discussed with real scenarios used for the simulation tests. After comparing the proposed algorithm with several other algorithms commonly used to solve optimization problems, the results show that the proposed algorithm is able to find the optimal solution quickly and accurately (i.e. to obtain the minimum cost for power generation in the shortest time). At the end, the impact to the total cost savings for power generation after adding (or not adding) wind power generation is also discussed. The actual implementation results prove that the proposed algorithm is economical, fast and practical. They are quite valuable for further research. -- Research highlights: → Quantum Genetic Algorithm can effectively improve the global search ability. → It can achieve the real objective of the global optimal solutions. → The CPU computation time is less than that other algorithms adopted in this paper.

  15. Flexible fault ride through strategy for wind farm clusters in power systems with high wind power penetration

    International Nuclear Information System (INIS)

    Wang, Songyan; Chen, Ning; Yu, Daren; Foley, Aoife; Zhu, Lingzhi; Li, Kang; Yu, Jilai

    2015-01-01

    Highlights: • A flexible fault ride through strategy is proposed. • The strategy comprises of grid code requirements and power restrictions. • Slight faults and moderate faults are the main defending objectives. • Temporary overloading capability of the doubly fed induction generator is considered. - Abstract: This paper investigates a flexible fault ride through strategy for power systems in China with high wind power penetration. The strategy comprises of adaptive fault ride through requirements and maximum power restrictions of the wind farms with weak fault ride through capabilities. The slight faults and moderate faults with high probability are the main defending objective of the strategy. The adaptive fault ride through requirement in the strategy consists of two sub fault ride through requirements, a temporary slight voltage ride through requirement corresponding to a slight fault incident, with a moderate voltage ride through requirement corresponding to a moderate fault. The temporary overloading capability of the wind farm is reflected in both requirements to enhance the capability to defend slight faults and to avoid tripping when the crowbar is disconnected after moderate faults are cleared. For those wind farms that cannot meet the adaptive fault ride through requirement, restrictions are put on the maximum power output. Simulation results show that the flexible fault ride through strategy increases the fault ride through capability of the wind farm clusters and reduces the wind power curtailment during faults

  16. An inversion strategy for energy saving in smart building through wireless monitoring

    Science.gov (United States)

    Anselmi, N.; Moriyama, T.

    2017-10-01

    The building plants represent one of the main sources of power consumption and of greenhouse gases emission in urban scenarios. The efficiency of energy management is also related to the indoor environmental conditions that reflect on the user comfort. The constant monitoring of comfort indicators enables the accurate management of building plants with the final objective of reducing energy waste and satisfying the user needs. This paper presents an inversion methodology based on support vector regression for the reconstruction and forecasting of the thermal comfort of users starting from the indoor environmental features of the building. The environmental monitoring is performed by means of a wireless sensor network, which pervasively measures the spatial variability of indoor conditions. The proposed system has been experimentally validated in a real test-site to assess the advantages and the limitations in supporting the management of the building plants towards energy saving.

  17. Nuclear power plant outage optimisation strategy

    International Nuclear Information System (INIS)

    2002-10-01

    Competitive environment for electricity generation has significant implications for nuclear power plant operations, including among others the need of efficient use of resources, effective management of plant activities such as on-line maintenance and outages. Nuclear power plant outage management is a key factor for good, safe and economic nuclear power plant performance which involves many aspects: plant policy, co-ordination of available resources, nuclear safety, regulatory and technical requirements and, all activities and work hazards, before and during the outage. This technical publication aims to communicate these practices in a way they can be used by operators and utilities in the Member States of the IAEA. It intends to give guidance to outage managers, operating staff and to the local industry on planning aspects, as well as examples and strategies experienced from current plants in operation on the optimization of outage period. This report discusses the plant outage strategy and how this strategy is actually implemented. The main areas identified as most important for outage optimization by the utilities and government organizations participating in this report are: organization and management; outage planning and preparation, outage execution, safety outage review, and counter measures to avoid extension of outages and to easier the work in forced outages. This report was based on discussions and findings by the authors of the annexes and the participants of an Advisory Group Meeting on Determinant Causes for Reducing Outage Duration held in June 1999 in Vienna. The report presents the consensus of these experts regarding best common or individual good practices that can be used at nuclear power plants with the aim to optimize

  18. Evaluation on Innovation approaches on Performance from Malaysian perspective: A study on Malaysian Building energy saving

    Directory of Open Access Journals (Sweden)

    Amlus M. H.

    2018-01-01

    Full Text Available Lately Malaysia energy consumption versus generation rapidly shows increasing due to increasing of load. This phenomenon happened following to advanced country development. Lacking on design and without energy management approach the energy consumption and monthly electrical bill will steadily increased and support the increasing of world carbon emission. Therefore the aim of this work is to approach the simplest innovation task-energy audit , which is load-apportioning strategy. This approach using matching the usage of equipment with fully utilized space and reschedules the time of usage. A one week data was collected by logged power meter at main switchboard at selected building using Fluke Power Recorder. From the data collected, current usage of every load can be determine, then load will be arrange into a group with same portion and same time of usage. The result shows clearly the energy consumption for every single day and indicates the highest and lowest peak. From this work the apportioning strategy implemented by rearrange the load following type of room application. After the arrangement, new measurement was taken and a very good result was established. This work also can be further apply for a huge load that can be save a lot of money for owner especially government by energy saving.

  19. Novel deadbeat power control strategy for grid connected systems

    Directory of Open Access Journals (Sweden)

    Yousry Atia

    2015-09-01

    Full Text Available This paper introduces a novel approach for power control of three phase voltage source inverter (VSI in grid connected distribution generation system. In this approach, the control of active and reactive power is based on deadbeat control strategy. First, the difference between the reference and actual currents are introduced in different approach. Then current to power substitutions are carried out to obtain direct relationship between the required inverter voltage and instantaneous power errors. There is no need for coordinate transformation or PLL, where the required inverter voltage vector calculations carried out in α–β stationary reference frame. The proposed technique introduces two cross coupling components in the control function. Including these two components, the controller can achieve nearly zero steady-state tracking error of the controlled variables. To obtain fixed switching frequency operations, space vector modulation (SVM is used to synthesize the required inverter voltage vector and to generate the switching pulses for the VSI. The proposed strategy has the simplicity of the direct power control (DPC technique and doesn’t require any current control loops. The proposed strategy is experimentally implemented using fixed-point microcontroller. Simulation and experimental results are presented to confirm the superiority of the proposed strategy.

  20. Energy-saving operation of a converter-fed synchronous machine

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, I.; Veszpremi, K. [Technical University of Budapest, Department of Electrical Machines and Drives, Budapest (Hungary)

    1997-12-31

    In the Converter-Fed Synchronous Machine (CFSM) there is no need for forced commutation the CL and CF converters operate with line commutation, the CM is commutated by the machine voltages. This drive is applied mainly for large power and high speed controlled drives. Considering the large power, the investigation of energy-saving operation is important. As in the DC and the induction motor drives the energy-saving operation is implemented by flux control. (orig.) 6 refs.

  1. Energy saving work of frequency controlled induction cage machine

    Energy Technology Data Exchange (ETDEWEB)

    Gnacinski, P. [Gdynia Maritime University, Department of Ship Electrical Power Engineering, Morska Str. 8, 81-225 Gdynia (Poland)]. E-mail: piotrg@am.gdynia.pl

    2007-03-15

    Energy saving work, understood as lowering the supply voltage when load torque is much less than rated, is one way of reducing power losses in an induction cage machine working with a variable load. Reduction in power losses also affects the thermal properties of an induction machine because the energy saving work allows the temperature rise of the windings to decrease. Thanks to a lower temperature of the windings, the same load torque can be carried by a machine of less rated power. The ability of energy saving work to reduce the temperature of windings depends on the thermal properties of an induction machine, which are different in the case of a machine with foreign ventilation and its own ventilation. This paper deals with the thermal effect of energy saving work on a frequency controlled induction cage machine. A comparison of the properties of a machine with its own and outside ventilation is presented. The results of the investigations are shown for a 3 kW induction cage machine with the two previously mentioned ways of ventilation: one provided with a fan placed on a shaft and the other provided with a fan driven by an auxiliary motor.

  2. Energy saving work of frequency controlled induction cage machine

    International Nuclear Information System (INIS)

    Gnacinski, P.

    2007-01-01

    Energy saving work, understood as lowering the supply voltage when load torque is much less than rated, is one way of reducing power losses in an induction cage machine working with a variable load. Reduction in power losses also affects the thermal properties of an induction machine because the energy saving work allows the temperature rise of the windings to decrease. Thanks to a lower temperature of the windings, the same load torque can be carried by a machine of less rated power. The ability of energy saving work to reduce the temperature of windings depends on the thermal properties of an induction machine, which are different in the case of a machine with foreign ventilation and its own ventilation. This paper deals with the thermal effect of energy saving work on a frequency controlled induction cage machine. A comparison of the properties of a machine with its own and outside ventilation is presented. The results of the investigations are shown for a 3 kW induction cage machine with the two previously mentioned ways of ventilation: one provided with a fan placed on a shaft and the other provided with a fan driven by an auxiliary motor

  3. Power and energy saving in buildings by distributed generation based on gas-engine systems

    Energy Technology Data Exchange (ETDEWEB)

    Arghandeh, R.; Amidpour, M.; Ghaffari, A. [Khaje Nasir Toosi Univ. of Technology, Tehran (Iran, Islamic Republic of). Joint Program of Energy Systems Engineering; Manchester Univ., Manchester (United Kingdom)

    2008-07-01

    Buildings consume high amounts of energy and produce high amounts of greenhouse gas (GHG) emissions. This paper discussed the use of gas cogeneration distributed generation (DG) technologies as a means of reducing energy consumption from buildings as well as energy losses from transmission lines in Iran. Energy sources and power generation systems were reviewed, and the economical benefits and energy savings resulting from the use of cogeneration systems were outlined. Actual rates of electricity consumption for Iran were estimated. Building power consumption was divided into the following 6 major sections: (1) lighting, (2) home appliances, (3) restaurant and cooking devices, (4) sports facilities, (5) utilities, and (6) electronics. Energy consumption criteria (ECC) and daily consumption charts (DCC) were used to plan and design the cogeneration systems. Energy balances, capital costs, and investment rates of return (IRR) were then calculated for 2 scenarios for a sample building. Results of the study showed that gas engine combined heat and power (CHP) DG systems are a reliable and economic technology for reducing energy consumption in buildings. The IRR of the CHP DG system for the sample building was achieved in 1 year. 13 refs., 10 tabs., 11 figs.

  4. Photon harvesting, coloring and polarizing in photovoltaic cell integrated color filters: efficient energy routing strategies for power-saving displays.

    Science.gov (United States)

    Wen, Long; Chen, Qin; Song, Shichao; Yu, Yan; Jin, Lin; Hu, Xin

    2015-07-03

    We describe the integral electro-optical strategies that combine the functionalities of photovoltaic (PV) electricity generation and color filtering as well as polarizing to realize more efficient energy routing in display technology. Unlike the conventional pigment-based filters and polarizers, which absorb substantial amounts of unwanted spectral components and dissipate them in the form of heat, we propose converting the energy of those photons into electricity by constructing PV cell-integrated color filters based on a selectively transmitting aluminum (Al) rear electrode perforated with nanoholes (NHs). Combining with a dielectric-metal-dielectric (DMD) front electrode, the devices were optimized to enable efficient cavity-enhanced photon recycling in the PV functional layers. We perform a comprehensive theoretical and numerical analysis to explore the extraordinary optical transmission (EOT) through the Al NHs and identify basic design rules for achieving structural coloring or polarizing in our PV color filters. We show that the addition of thin photoactive polymer layers on the symmetrically configured Al NH electrode narrows the bandwidth of the EOT-assisted high-pass light filtering due to the strongly damped anti-symmetric coupling of the surface modes excited on the front and rear surface of the Al NHs, which facilitates the whole visible coloring with relatively high purity for the devices. By engineering the cut-off characteristics of the plasmonic waveguide mode supported by the circular or ellipsoidal Al NHs, beyond the photon recycling capacity, PV color filters and PV polarizing color filters that allow polarization-insensitive and strong polarization-anisotropic color filtering were demonstrated. The findings presented here may shed some light on expanding the utilization of PV electricity generation across new-generation energy-saving electrical display devices.

  5. Nuclear Power Plant Outage Optimization Strategy. 2016 Edition

    International Nuclear Information System (INIS)

    2016-10-01

    This publication is an update of IAEA-TECDOC-1315, Nuclear Power Plant Outage Optimisation Strategy, which was published in 2002, and aims to communicate good outage management practices in a manner that can be used by operators and utilities in Member States. Nuclear power plant outage management is a key factor for safe and economic nuclear power plant performance. This publication discusses plant outage strategy and how this strategy is actually implemented. The main areas that are important for outage optimization that were identified by the utilities and government organizations participating in this report are: 1) organization and management; 2) outage planning and preparation; 3) outage execution; 4) safety outage review; and 5) counter measures to avoid the extension of outages and to facilitate the work in forced outages. Good outage management practices cover many different areas of work and this publication aims to communicate these good practices in a way that they can be used effectively by operators and utilities

  6. Simplified reactive power management strategy for complex power grids under stochastic operation and incomplete information

    DEFF Research Database (Denmark)

    Vlachogiannis, Ioannis (John)

    2009-01-01

    grids is a major issue for system operators. Under these circumstances an online reactive power management strategy with minimum risk concerning all uncertain and stochastic parameters is proposed. Therefore, new concepts such as reactive power-weighted node-to-node linking and reactive power control......In the current released energy market, the large-scale complex transmission networks and the distribution ones with dispersed energy sources and "intelligent" components operate under uncertainties, stochastic and prior incomplete information. A safe and reliable operation of such complex power...... capability are introduced. A distributed and interconnected stochastic learning automata system is implemented to manage, in a unified and unique way, the reactive power in complex power grids with stochastic reactive power demand and detect the vulnerable part. The proposed simplified strategy can also...

  7. Who's in the business of saving lives?

    Science.gov (United States)

    Lee Chang, Pepe

    2006-10-01

    There are individuals, including children, dying needlessly in poverty-stricken third world countries. Many of these deaths could be prevented if pharmaceutical companies provided the drugs needed to save their lives. Some believe that because pharmaceutical companies have the power to save lives, and because they can do so with little effort, they have a special obligation. I argue that there is no distinction, with respect to obligations and responsibilities, between pharmaceutical companies and other types of companies. As a result, to hold pharmaceutical companies especially responsible for saving lives in third world countries is unjustified.

  8. Technical Support Document: Strategies for 50% Energy Savings in Large Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Leach, M.; Lobato, C.; Hirsch, A.; Pless, S.; Torcellini, P.

    2010-09-01

    This Technical Support Document (TSD) documents technical analysis that informs design guidance for designing and constructing large office buildings that achieve 50% net site energy savings over baseline buildings defined by minimal compliance with respect to ANSI/ASHRAE/IESNA Standard 90.1-2004. This report also represents a step toward developing a methodology for using energy modeling in the design process to achieve aggressive energy savings targets. This report documents the modeling and analysis methods used to identify design recommendations for six climate zones that capture the range of U.S. climate variability; demonstrates how energy savings change between ASHRAE Standard 90.1-2007 and Standard 90.1-2004 to determine baseline energy use; uses a four-story 'low-rise' prototype to analyze the effect of building aspect ratio on energy use intensity; explores comparisons between baseline and low-energy building energy use for alternate energy metrics (net source energy, energy emissions, and energy cost); and examines the extent to which glass curtain construction limits achieve energy savings by using a 12-story 'high-rise' prototype.

  9. A Novel Sensor Platform Matching the Improved Version of IPMVP Option C for Measuring Energy Savings

    OpenAIRE

    Tseng, Yen-Chieh; Lee, Da-Sheng; Lin, Cheng-Fang; Chang, Ching-Yuan

    2013-01-01

    It is easy to measure energy consumption with a power meter. However, energy savings cannot be directly computed by the powers measured using existing power meter technologies, since the power consumption only reflects parts of the real energy flows. The International Performance Measurement and Verification Protocol (IPMVP) was proposed by the Efficiency Valuation Organization (EVO) to quantify energy savings using four different methodologies of A, B, C and D. Although energy savings can be...

  10. Energy-Saving RAM-Power Tap

    Science.gov (United States)

    Bruner, Alan Roy

    1987-01-01

    Reverse-flow HEXFET(R) minimizes voltage drop and power dissipation. HEXFET(R) scheme reduces voltage drop by approximately 80 percent. Design for power tap for random-access memory (RAM) has potential application in digital systems.

  11. Strategy of nuclear power in Korea, non-nuclear-weapon state and peaceful use of nuclear power

    International Nuclear Information System (INIS)

    Nagasaki, Takao

    2005-01-01

    The nuclear power plant started at Kori in Korea in April, 1978. Korea has carried out development of nuclear power as a national policy. The present capacity of nuclear power plants takes the sixes place in the world. It supplies 42% total power generation. The present state of nuclear power plant, nuclear fuel cycle facility, strategy of domestic production of nuclear power generation, development of next generation reactor and SMART, strategy of export in corporation with industry, government and research organization, export of nuclear power generation in Japan, nuclear power improvement project with Japan, Korea and Asia, development of nuclear power system with nuclear diffusion resistance, Hybrid Power Extraction Reactor System, radioactive waste management and construction of joint management and treatment system of spent fuel in Asia are stated. (S.Y.)

  12. District energy-saving visions for Town of Towa; Towa machi chiiki sho energy vision

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-02-01

    The energy-saving visions are drawn for Town of Towa, Iwate Pref., to promote energy saving and abatement of gas emissions which cause global warming. The priority projects in the energy-saving visions include introduction of energy-saving type vehicles, houses/buildings, illuminators; introduction of solar energy utilization systems and alternative energy (e.g., wood, wastes from domestic animals and microhydroelectric power generation); and monitoring/observation of energy consumption situations and energy-saving education. The energy-saving target is set at 3,120kL as crude oil. The energy-saving activities studied for the administrative and public sectors include introduction of energy-saving type vehicles and buildings; introduction of solar energy utilization systems (for roads and public facilities when they are replaced) and microhydroelectric power generation; and monitoring/observation of energy consumption situations and energy-saving education. The energy-saving target is set at 80kL as crude oil. (NEDO)

  13. Fuel and power resources based on energy-saving technologies and technical means in agriculture

    Directory of Open Access Journals (Sweden)

    A. V. Tikhomirov

    2015-01-01

    Full Text Available The state and efficiency of the use of the energy supply systems in agriculture were analyzed. It is demonstrated that grids and power equipment deterioration exceeds 30 percent, and fuel volume-efficiency ratio is not more than 35 percent in this sector. A considerable part of the country territory (mainly the northern one does not have centralized power supply. Decentralized cogeneration systems with extensive use of renewable energy sources and local energy recourses are highly efficient for this part. A necessity of development of methodology and recommendations for the selection of efficient systems and technical means of power supply to agricultural enterprises was substantiated with due consideration of their location, load intensity and distance from centralized grids. The most important indication of energy efficiency is energy intensity of products and energy inputs share in the production cost. Reserves for energy saving including the development of energy-efficient technologies and technical means, some of which have already been developed (equipment for lighting, microclimate, primary treatment and storage of products, disinfection or are at the completion stage were presented. Their implementation in agricultural production will make it possible to raise considerably the efficiency of the use of fuel and power resources and to reduce energy consumption. The conditions in which the use of decentralized power supply systems is most efficient were educed. The characteristics of related equipment and the specifics of its use at agricultural enterprises are described. The proposal and priority actions for the development and upgrading of power supply systems for agriculture have been elaborated.

  14. Savings through the use of adaptive predictive control of thermo-active building systems (TABS): A case study

    International Nuclear Information System (INIS)

    Schmelas, Martin; Feldmann, Thomas; Bollin, Elmar

    2017-01-01

    Highlights: •An adaptive and predictive algorithm for the control of TABS (AMLR) is evaluated. •Comparison of standard TABS control and AMLR over a period of nine month each. •Thermal comfort, energy and investment savings in a passive seminar building. •Reduction of peak power of chilled beams (auxiliary system) with AMLR algorithm. •Simplification of the TABS hydraulics with AMLR algorithm. -- Abstract: The building sector is one of the main consumers of energy. Therefore, heating and cooling concepts for renewable energy sources become increasingly important. For this purpose, low-temperature systems such as thermo-active building systems (TABS) are particularly suitable. This paper presents results of the use of a novel adaptive and predictive computation method, based on multiple linear regression (AMLR) for the control of TABS in a passive seminar building. Detailed comparisons are shown between the standard TABS and AMLR strategies over a period of nine months each. In addition to the reduction of thermal energy use by approx. 26% and a significant reduction of the TABS pump operation time, this paper focuses on investment savings in a passive seminar building through the use of the AMLR strategy. This includes the reduction of peak power of the chilled beams (auxiliary system) as well as a simplification of the TABS hydronic circuit and the saving of an external temperature sensor. The AMLR proves its practicality by learning from the historical building operation, by dealing with forecasting errors and it is easy to integrate into a building automation system.

  15. PAQ Types and Power Strategies Used in Intimate Relationships.

    Science.gov (United States)

    Falbo, Toni

    1982-01-01

    Examined kinds of power strategies used by masculine, feminine, androgynous, and undifferentiated people in their intimate relationships. Androgynous people reported using primarily bilateral strategies, such as persuasion. Undifferentiated people reported using primarily unilateral strategies, such as doing what they wanted, regardless of their…

  16. Wind Farm Active Power Dispatch for Output Power Maximizing Based on a Wind Turbine Control Strategy for Load Minimizing

    DEFF Research Database (Denmark)

    Zhang, Baohua; Hu, Weihao; Hou, Peng

    2015-01-01

    Inclusion of the wake effect in the wind farm control design (WF) can increase the total captured power by wind turbines (WTs), which is usually implemented by derating upwind WTs. However, derating the WT without a proper control strategy will increase the structural loads, caused by operation...... in stall mode. Therefore, the WT control strategy for derating operation should be considered in the attempt at maximizing the total captured power while reducing structural loads. Moreover, electrical power loss on the transmission system inside a WF is also not negligible for maximizing the total output...... power of the WF. In this paper, an optimal active power dispatch strategy based on a WT derating strategy and considering the transmission loss is proposed for maximizing the total output power. The active power reference of each WT is chosen as the optimization variable. A partial swarm optimizing...

  17. Energy managment strategies for vehicular electric power systems

    NARCIS (Netherlands)

    Koot, M.W.T.; Kessels, J.T.B.A.; Jager, de A.G.; Heemels, W.P.M.H.; Bosch, van den P.P.J.; Steinbuch, M.

    2005-01-01

    In the near future, a significant increase in electric power consumption in vehicles is expected. To limit the associated increase in fuel consumption and exhaust emissions, smart strategies for the generation, storage/retrieval, distribution, and consumption of electric power will be used. Inspired

  18. The role of global public health strategy in non-profit organisational change at country level: lessons from the joining of Save the Children and Merlin in Myanmar.

    Science.gov (United States)

    Campbell, Fiona M; Balabanova, Dina; Howard, Natasha

    2018-01-01

    The paper presents a case study that critically assesses the role of global strategy 'Public Health on the Frontline 2014-2015' ('the Strategy') in supporting Merlin and Save the Children's organisational change and future programme of the combined organisation in Myanmar. Research was undertaken in 2014 in Myanmar. Twenty-six individual and three group interviews were conducted with stakeholders, and 10 meetings relevant to the country organisational transition process were observed. A conceptual framework was developed to assess the role of the global strategy in supporting the country change process. Several positive aspects of the global strategy were found, as well as critical shortcomings in its support to the organisational change process at country level. The strategy was useful in signalling Save the Children's intention to scale up humanitarian health provision. However, it had only limited influence on the early change process and outcomes in Myanmar. Results highlight several aspects that would enhance the role of a global strategy at country level. Lessons can be applied by organisations undertaking a similar process. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  19. Locomotive energy savings possibilities

    Directory of Open Access Journals (Sweden)

    Leonas Povilas LINGAITIS

    2009-01-01

    Full Text Available Economic indicators of electrodynamic braking have not been properly estimated. Vehicles with alternative power trains are transitional stage between development of pollution- free vehicles. According to these aspects the investigation on conventional hybrids drives and their control system is carried out in the article. The equation that allows evaluating effectiveness of regenerative braking for different variants of hybrid drive are given. Presenting different types of locomotive energy savings power systems, which are using regenerative braking energy any form of hybrid traction vehicles systems, circuit diagrams, electrical parameters curves.

  20. Feedback power control strategies in wireless sensor networks with joint channel decoding.

    Science.gov (United States)

    Abrardo, Andrea; Ferrari, Gianluigi; Martalò, Marco; Perna, Fabio

    2009-01-01

    In this paper, we derive feedback power control strategies for block-faded multiple access schemes with correlated sources and joint channel decoding (JCD). In particular, upon the derivation of the feasible signal-to-noise ratio (SNR) region for the considered multiple access schemes, i.e., the multidimensional SNR region where error-free communications are, in principle, possible, two feedback power control strategies are proposed: (i) a classical feedback power control strategy, which aims at equalizing all link SNRs at the access point (AP), and (ii) an innovative optimized feedback power control strategy, which tries to make the network operational point fall in the feasible SNR region at the lowest overall transmit energy consumption. These strategies will be referred to as "balanced SNR" and "unbalanced SNR," respectively. While they require, in principle, an unlimited power control range at the sources, we also propose practical versions with a limited power control range. We preliminary consider a scenario with orthogonal links and ideal feedback. Then, we analyze the robustness of the proposed power control strategies to possible non-idealities, in terms of residual multiple access interference and noisy feedback channels. Finally, we successfully apply the proposed feedback power control strategies to a limiting case of the class of considered multiple access schemes, namely a central estimating officer (CEO) scenario, where the sensors observe noisy versions of a common binary information sequence and the AP's goal is to estimate this sequence by properly fusing the soft-output information output by the JCD algorithm.

  1. Feedback Power Control Strategies inWireless Sensor Networks with Joint Channel Decoding

    Directory of Open Access Journals (Sweden)

    Fabio Perna

    2009-11-01

    Full Text Available In this paper, we derive feedback power control strategies for block-faded multiple access schemes with correlated sources and joint channel decoding (JCD. In particular, upon the derivation of the feasible signal-to-noise ratio (SNR region for the considered multiple access schemes, i.e., the multidimensional SNR region where error-free communications are, in principle, possible, two feedback power control strategies are proposed: (i a classical feedback power control strategy, which aims at equalizing all link SNRs at the access point (AP, and (ii an innovative optimized feedback power control strategy, which tries to make the network operational point fall in the feasible SNR region at the lowest overall transmit energy consumption. These strategies will be referred to as “balanced SNR” and “unbalanced SNR,” respectively. While they require, in principle, an unlimited power control range at the sources, we also propose practical versions with a limited power control range. We preliminary consider a scenario with orthogonal links and ideal feedback. Then, we analyze the robustness of the proposed power control strategies to possible non-idealities, in terms of residual multiple access interference and noisy feedback channels. Finally, we successfully apply the proposed feedback power control strategies to a limiting case of the class of considered multiple access schemes, namely a central estimating officer (CEO scenario, where the sensors observe noisy versions of a common binary information sequence and the AP’s goal is to estimate this sequence by properly fusing the soft-output information output by the JCD algorithm.

  2. Advances in Biological Water-saving Research: Challenge and Perspectives

    Institute of Scientific and Technical Information of China (English)

    Lun Shan; Xiping Deng; Suiqi Zhang

    2006-01-01

    Increasing the efficiency of water use by crops continues to escalate as a topic of concern because drought is a restrictive environmental factor for crop productivity worldwide. Greater yield per unit rainfall is one of the most important challenges in water-saving agriculture. Besides water-saving by irrigation engineering and conservation tillage, a good understanding of factors limiting and/or regulating yield now provides us with an opportunity to identify and then precisely select for physiological and breeding traits that increase the efficiency of water use and drought tolerance under water-limited conditions, biological water-saving is one means of achieving this goat. A definition of biological water-saving measures is proposed which embraces improvements in water-use efficiency (WUE) and drought tolerance, by genetic improvement and physiological regulation. The preponderance of biological water-saving measures is discussed and strategies identified for working within natural resource constraints. The technology and future perspectives of biological water saving could provide not only new water-saving techniques but also a scientific base for application of water-saving irrigation and conservation tillage.

  3. Battery Peak Power Shaving Strategy to Prolong Battery Life for Electric Buses

    NARCIS (Netherlands)

    Pham, T.H.; Rosea, B.; Wilkins, S.

    2016-01-01

    This paper presents a battery peak power shaving strategy for battery electric buses. The developed strategy restricts the battery charge/discharge power when the propulsion power demand is high to avoid high deterioration of the battery capacity during operation. Without reducing the propulsion

  4. Control Strategy of Active Power Filter Based on Modular Multilevel Converter

    Science.gov (United States)

    Xie, Xifeng

    2018-03-01

    To improve the capacity, pressure resistance and the equivalent switching frequency of active power filter (APF), a control strategy of APF based on Modular Multilevel Converter (MMC) is presented. In this Control Strategy, the indirect current control method is used to achieve active current and reactive current decoupling control; Voltage Balance Control Strategy is to stabilize sub-module capacitor voltage, the predictive current control method is used to Track and control of harmonic currents. As a result, the harmonic current is restrained, and power quality is improved. Finally, the simulation model of active power filter controller based on MMC is established in Matlab/Simulink, the simulation proves that the proposed strategy is feasible and correct.

  5. Minimum energy consumption process synthesis for energy saving

    Energy Technology Data Exchange (ETDEWEB)

    Xiao-Ping, Jia [Institute for Petroleum and Chemical Industry, Qingdao University of Science and Technology, Qingdao 266042, Shandong (China); Department of Environmental Science and Engineering, Tsinghua University, Beijing 100084 (China); Fang, Wang; Shu-Guang, Xiang; Xin-Sun, Tan; Fang-Yu, Han [Institute for Petroleum and Chemical Industry, Qingdao University of Science and Technology, Qingdao 266042, Shandong (China)

    2008-05-15

    The paper presents a synthesis strategy for the chemical processes with energy saving. The concept of minimum energy consumption process (MECP) is proposed. Three characteristics of MECP are introduced, including thermodynamic minimum energy demand, energy consumption efficiency and integration degree. These characteristics are evaluated according to quantitative thermodynamic analysis and qualitative knowledge rules. The procedure of synthesis strategy is proposed to support the generation of MECP alternatives, which combine flowsheet integration and heat integration. The cases studies will focus on how integration degrees of a process affect the energy-saving results. The separation sequences of the hydrodealkylation of toluene (HDA) process and ethanol distillation process as case studies are used to illustrate. (author)

  6. INDIRECT COMMUNICATION AND FACE-SAVING FACTOR: FROM THEORY TO PRACTICE

    Directory of Open Access Journals (Sweden)

    ROZINA GUNTA

    2015-01-01

    Full Text Available The paper analyses silence as a non-linguistic resource for conveying indirect communicative acts. Applied linguists assert that the use of silence for communicative purposes might be determined by several categories of factors, the face-saving factor being one of them. So far, much research has been done to determine how the speakers of different languages use silence; however, only limited research on silence as a strategy for face saving can be identified. Thus, the current investigation was undertaken to explore the relationship between the face-saving factor and non-verbal communication where silence as a strategy for indirect interaction was applied. Within this framework, the study dealt with the analysis of silence as a workable strategy that is often adopted in non-native speakers’ communication in English. With this purpose, four focus groups of non-native speakers (NNSs of English in Latvia were selected. The investigation was approached from the perspective of qualitative research, and it applied a case study as the research method. The study has acquired two types of findings. First, when the target language is applied for interactional purposes, NNSs of the English language are influenced by cognitive and pragma-social factors. Second, when NNSs adopt both aspects of language, i.e., verbal and non-verbal, for interaction, the strategy depends on numerous factors, silence being one of them. The study has demonstrated that silence is often applied to communicate information indirectly, and it is frequently used as a face-saving strategy in interaction in the target language. The use of silence as a communicative strategy depends on numerous factors in different non-native language users’ settings and varies according to the focus of interactional purposes.

  7. Design a Smart Control Strategy to Implement an Intelligent Energy Safety and Management System

    OpenAIRE

    Jing-Min Wang; Ming-Ta Yang

    2014-01-01

    The energy saving and electricity safety are today a cause for increasing concern for homes and buildings. Integrating the radio frequency identification (RFID) and ZigBee wireless sensor network (WSN) mature technologies, the paper designs a smart control strategy to implement an intelligent energy safety and management system (IESMS) which performs energy measuring, controlling, monitoring, and saving of the power outlet system. The presented RFID and billing module is used to identify user...

  8. New York Power Authority`s energy-efficient refigerator program for the New York City Housing Authority - savings evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Pratt, R.G.; Miller, J.D.

    1997-09-01

    The New York Power Authority (NYPA) and the New York City Housing Authority (NYCHA) are replacing refrigerators in New York City public housing with new, highly energy-efficient models over a five-year period. This report describes the analysis of the energy cost savings achieved through the replacement of 20,000 refrigerators in 1996, the first year of the NYPA/NYCHA program. The NYPA/NYCHA project serves as the lynchpin of a larger program designed to offer energy-efficient appliances to housing authorities across the country. The national program is a partnership between the U.S. Department of Energy (DOE) and the Consortium for Energy Efficiency (CEE). Starting with the 1997 refrigerator contract, this program invites other housing authorities to join NYPA in its volume purchase of energy-efficient refrigerators, at the same price and terms available to NYPA. Through these volume purchases, DOE`s ENERGY STAR{reg_sign} Partnerships program hopes to encourage appliance manufacturers to bring more efficient appliances to the market and to provide volume purchasers with the per-unit price savings of a bulk purchaser. DOE asked the Pacific Northwest National Laboratory (PNNL) to establish a protocol for evaluating the savings achieved with the NYPA refrigerators. That protocol is summarized in this report.

  9. Implementation of energy-saving policies in China: How local governments assisted industrial enterprises in achieving energy-saving targets

    International Nuclear Information System (INIS)

    Zhao, Xiaofan; Li, Huimin; Wu, Liang; Qi, Ye

    2014-01-01

    Local governments have replaced the national ministries that are in charge of various industries to become the primary implementer of energy-saving policies in China since 2000. This paper employs a case study-based approach to demonstrate the significance of local governments’ policy measures in assisting industrial enterprises with energy-saving activities in China. Based on the longitudinal case of the Jasmine Thermal Electric Power Company, this paper hypothesizes that sub-national governments have played a major role in implementing energy-saving policies in China since the 11th Five-year-plan period. A wide range of provincial and municipal agencies collaborated in implementing five types of policy measures – informational policy, skill building, improved enforcement of central directives, price adjustment, and funding – that reduced barriers to energy saving and motivated active pursuit of energy-saving activities at industrial enterprises. The case study demonstrates how an enterprise and local governments work together to achieve the enterprise's energy-saving target. The authors will investigate the hypothesis of this paper in the context of multiple case studies that they plan to undertake in the future. - Highlights: • We employ a case study-based approach to study policy implementation in China. • Local governments have played a major role in implementing energy-saving policies. • Local public agencies collaborated in implementing five types of policy measures. • Local policy measures reduced barriers to energy saving at industrial enterprises. • Enterprises and local governments work together to achieve energy-saving targets

  10. A control strategy for multi-functional converter to improve grid power quality

    DEFF Research Database (Denmark)

    Li, Fei; Wang, Xiongfei; Chen, Zhe

    2011-01-01

    The extensive use of converter-interfacing distributed energy resources (DER), combined with a large amount of nonlinear and unbalanced loads connected to the distribution power system, has led to power quality problem. This paper proposes a control strategy for a three-phase four-leg multi-funct......) for multi-functional converter is described. Simulation and hardware in the loop real time test results carried on a three-phase four-wire distributed generation system illustrate the effectiveness of the proposed control strategy.......The extensive use of converter-interfacing distributed energy resources (DER), combined with a large amount of nonlinear and unbalanced loads connected to the distribution power system, has led to power quality problem. This paper proposes a control strategy for a three-phase four-leg multi......-functional converter which can compensate reactive power, harmonic currents, unbalance, and neutral current simultaneously under distorted voltage conditions, besides the active power exchange. The capacity of the converter is taken into account. The proposed control strategy based on synchronous reference frame (SRF...

  11. Evaluation of Electric Power Procurement Strategies by Stochastic Dynamic Programming

    Science.gov (United States)

    Saisho, Yuichi; Hayashi, Taketo; Fujii, Yasumasa; Yamaji, Kenji

    In deregulated electricity markets, the role of a distribution company is to purchase electricity from the wholesale electricity market at randomly fluctuating prices and to provide it to its customers at a given fixed price. Therefore the company has to take risk stemming from the uncertainties of electricity prices and/or demand fluctuation instead of the customers. The way to avoid the risk is to make a bilateral contact with generating companies or install its own power generation facility. This entails the necessity to develop a certain method to make an optimal strategy for electric power procurement. In such a circumstance, this research has the purpose for proposing a mathematical method based on stochastic dynamic programming and additionally considering the characteristics of the start-up cost of electric power generation facility to evaluate strategies of combination of the bilateral contract and power auto-generation with its own facility for procuring electric power in deregulated electricity market. In the beginning we proposed two approaches to solve the stochastic dynamic programming, and they are a Monte Carlo simulation method and a finite difference method to derive the solution of a partial differential equation of the total procurement cost of electric power. Finally we discussed the influences of the price uncertainty on optimal strategies of power procurement.

  12. Design of sensor energy-saving controller for photovoltaic power generation%光伏发电中的传感器节能控制器设计

    Institute of Scientific and Technical Information of China (English)

    云彩霞; 李丽芬; 蔡小庆; 刘晨

    2017-01-01

    传感器储能性能较弱,导致设计出的光伏发电中的传感器节能控制器网络延迟较长、节能效果不理想。因而,设计一种新型光伏发电中的传感器节能控制器,其对供电电路、无线通信芯片和太阳光传感器芯片进行重点设计。nRF905无线通信芯片对控制器中各设备、电路、元件之间的数据通信进行监控,保障节能效果、缩短网络延迟。供电电路为控制器的节能工作供应电能、优化太阳光光强的能量转化。优化后的太阳光能量,将通过太阳光传感器中的TSL2678芯片太阳光进行参数提取和分析,输出太阳能最佳采集方位和该方位的太阳光光强,实现光伏发电的最优节能。控制器软件设计部分给出了控制器的节能控制流程。分析实验结果可知,所设计的控制器具有网络延迟短、节能效果好的特点。%Since the sensor energy⁃saving controller for the photovoltaic power generation has long network latency and un⁃satisfied energy⁃saving effect due to the poor energy storage performance of the sensor,a new sensor energy⁃saving controller for the photovoltaic power generation was designed,and its power supply circuit,wireless communication chip and solar sensor chip were designed emphatically. The wireless communication chip NRF905 is used to monitor the data communication among each device,circuit and component in the controller to ensure the energy⁃saving effect and shorten the network latency. The power supply circuit supplies the electric energy for the energy⁃saving work of the controller,and optimizes the energy conversion of so⁃lar light. The parameters of the optimized solar light energy are extracted and analyzed through the chip TSL2678 in the solar light sensor,which outputs the optimal acquisition orientation of the solar energy and its intensity to realize the optimal energy saving of the photovoltaic power generation. The energy⁃saving

  13. Performance evaluation of control strategies for power maneuvering event of the KALIMER-600

    International Nuclear Information System (INIS)

    Seong, Seong-Hwan; Kim, Seong-O

    2012-01-01

    Highlights: ► The performance of three power control strategies of the KALIMER-600 was evaluated. ► There are turbine-, reactor- and feedwater-leading strategies in this study. ► For this, a performance analysis code was developed in this study. ► Simulation results show the turbine-leading is the best alternative. ► The feedwater-leading seems to be the second option. - Abstract: A sodium-cooled fast reactor named KALIMER-600 has been under development at KAERI. It is a pool-type reactor with the intermediate loops filled with sodium and has a superheated steam cycle with the once-through steam generators. Since the characteristic of the power control of the KALIMER-600 is expected to be different with that of a conventional power plant, the performance of the turbine-leading, reactor-leading and feedwater-leading control strategies for a power maneuvering event of the KALIMER-600 was evaluated in this study. The turbine-leading and reactor-leading strategies are very similar to those of a conventional water reactor but the feedwater-leading strategy is very similar to that of a fossil plant. Also, a performance analysis code which can analyze the plant dynamics of the KALIMER-600 and simulate the control actions during a power maneuvering event was developed. To evaluate the performance of control strategies, a simple power maneuvering event including a 10% step change and a ramp change with a rate of 5%/min was assumed and simulated. Through the simulation results, the turbine-leading strategy is proven to be very suitable for the KALIMER-600 and the feedwater-leading strategy for power maneuvering seems to be a good alternative for the power control. In further studies, various performance-related events such as the reactor power cutback, turbine runback and some transients will be evaluated and the best control strategy will be suggested.

  14. Minimal average consumption downlink base station power control strategy

    OpenAIRE

    Holtkamp H.; Auer G.; Haas H.

    2011-01-01

    We consider single cell multi-user OFDMA downlink resource allocation on a flat-fading channel such that average supply power is minimized while fulfilling a set of target rates. Available degrees of freedom are transmission power and duration. This paper extends our previous work on power optimal resource allocation in the mobile downlink by detailing the optimal power control strategy investigation and extracting fundamental characteristics of power optimal operation in cellular downlink. W...

  15. Mass savings domain of plasma propulsion for LEO to GEO transfer

    International Nuclear Information System (INIS)

    Choueiri, E.Y.; Kelly, A.J.; Jahn, R.G.

    1993-01-01

    A parametric model is used to study the mass savings of plasma propulsion over advanced chemical propulsion for lower earth orbit (LEO) to geosynchronous orbit (GEO) transfer. Such savings are characterized by stringent requirements of massive payloads (O(10) metric tons) and high power levels (O(100) kW). Mass savings on the order of the payload mass are possible but at the expense of longer transfer times (8--20 months). Typical of the savings domain is the case of a self-field magnetoplasmadynamic (MPD) thruster running quasi-steadily, at an I s of 2000 s, with 600 kW of input power, raising a 50 metric ton satellite in 270 days. The initial mass at LEO will be 65 tons less than a 155 ton LO 2 /LH 2 advanced chemical high thrust spacecraft. An optimum I s can only be found if the cost savings associated with mass savings are counterbalanced by the cost losses incurred by longer transfer times. A simplistic cost model that illustrates the overall trends in the optimization yielded an optimum I s of about 2200 s for a cost effective baseline MPD system

  16. Bidding strategy in pay-as-bid power markets

    International Nuclear Information System (INIS)

    Oloomi-Buygi, M.; Nazarian, H.

    2007-01-01

    Electricity markets around the world can be classified as pool-based electricity markets; pure bilateral contract markets; and hybrid markets. The bidding strategy has emerged as an important issue for producers in pool-based electricity markets. Power producers can use several approaches to develop bidding strategies that determine the optimal bid to maximize profit. The various approaches fall into 2 categories, notably forecasting market clearing prices, and estimating the behaviour of other competitors. This paper presented a simple and efficient approach for developing a bidding strategy in pay-as-bid electricity markets. It used the multiple step bid to estimate the optimal bid. One step was allocated to revenue earning while the other steps were allocated to information acquiring. Information acquiring steps obtain information from the market for estimating the optimal bid of the next day. The proposed method was used at a specified power generating unit operating in the Iranian electricity market. The study showed that the proposed bidding strategy can increase the total revenue of the unit by thirty nine per cent. 22 refs., 8 figs

  17. Space nuclear power: a strategy for tomorrow

    International Nuclear Information System (INIS)

    Buden, D.; Angelo, J. Jr.

    1981-01-01

    Energy: reliable, portable, abundant and low cost will be a most critical factor, perhaps the sine qua non, for the unfolding of man's permanent presence in space. Space-based nuclear power, in turn, is a key technology for developing such space platforms and the transportation systems necessary to service them. A strategy for meeting space power requirements is the development of a 100-kW(e) nuclear reactor system for high earth orbit missions, transportation from Shuttle orbits to geosynchronous orbit, and for outer planet exploration. The component technology for this nuclear power plant is now underway at the Los Alamos National Laboratory. As permanent settlements are established on the Moon and in space, multimegawatt power plants will be needed. This would involve different technology similar to terrestrial nuclear power plants

  18. Measured energy savings and cost-effectiveness of conservation retrofits in commercial buildings

    International Nuclear Information System (INIS)

    Greely, K.M.; Harris, J.P.; Hatcher, A.M.

    1990-01-01

    In this study, the authors examine the measured savings and cost-effectiveness of 447 commercial retrofit projects in the US, Canada, and Europe, representing over 1,700 buildings. For these projects, they examine savings and cost-effectiveness by building type and retrofit strategy, savings from individual measures, peak electric demand savings, comparisons of measured vs. predicted savings, and the persistence of savings in the years following a retrofit. Median annual site energy savings amounted to 20 kBtu/ft 2 , or 18% of whole-building usage; median retrofit cost was $0.56/ft 2 (1988 $), the median payback time was 3.1 years, and the median cost of conserved energy was $3.10/site MBtu. When examined by retrofit strategy, they found that projects with only HVAC and/or lighting retrofits had median payback times of one to three years, while those affecting the building shell, either alone or in combination with other types of measures, had payback times of five or more years. Projects in which only maintenance practices were changed typically saved 12% of their pre-retrofit consumption, often using in-house labor. Their research suggests that, despite significant savings and short payback times for the majority of projects, optimum savings are often not being achieved, due to limited owner willingness to invest in all cost-effective measures, as well as to improper retrofit installation and/or maintenance. A comprehensive understanding of energy management as a process is needed, including both inspection and commissioning of installed retrofits and ongoing tracking of energy consumption as an indicator of operating problems

  19. Optimal Offering Strategies for Wind Power in Energy and Primary Reserve Markets

    DEFF Research Database (Denmark)

    Soares, Tiago; Pinson, Pierre; Jensen, Tue Vissing

    2016-01-01

    generation from the turbines. These offering strategies aim at maximizing expected revenues from both market floors using probabilistic forecasts for wind power generation, complemented with estimated regulation costs and penalties for failing to provide primary reserve. A set of numerical examples, as well......Wind power generation is to play an important role in supplying electric power demand, and will certainly impact the design of future energy and reserve markets. Operators of wind power plants will consequently develop adequate offering strategies, accounting for the market rules...... and the operational capabilities of the turbines, e.g., to participate in primary reserve markets. We consider two different offering strategies for joint participation of wind power in energy and primary reserve markets, based on the idea of proportional and constant splitting of potentially available power...

  20. Evalutation of retrofitting strategies for energy savings in Brazilian hotels

    NARCIS (Netherlands)

    Cademartori, E.; Mutani, G.; Costola, D.; Hensen, J.L.M.

    2012-01-01

    ABSTRACT. A strong increase of hospitality infrastructure is taking place in Brazil due to imminent international events. In order to understand energy saving potential of this sector, an existing business hotel in Goiania, a mid-western Brazilian metropolis, was analyzed as case study taking into

  1. A Game Theoretical Approach Based Bidding Strategy Optimization for Power Producers in Power Markets with Renewable Electricity

    Directory of Open Access Journals (Sweden)

    Yi Tang

    2017-05-01

    Full Text Available In a competitive electricity market with substantial involvement of renewable electricity, maximizing profits by optimizing bidding strategies is crucial to different power producers including conventional power plants and renewable ones. This paper proposes a game-theoretic bidding optimization method based on bi-level programming, where power producers are at the upper level and utility companies are at the lower level. The competition among the multiple power producers is formulated as a non-cooperative game in which bidding curves are their strategies, while uniform clearing pricing is considered for utility companies represented by an independent system operator. Consequently, based on the formulated game model, the bidding strategies for power producers are optimized for the day-ahead market and the intraday market with considering the properties of renewable energy; and the clearing pricing for the utility companies, with respect to the power quantity from different power producers, is optimized simultaneously. Furthermore, a distributed algorithm is provided to search the solution of the generalized Nash equilibrium. Finally, simulation results were performed and discussed to verify the feasibility and effectiveness of the proposed non-cooperative game-based bi-level optimization approach.

  2. Trigeneration primary energy saving evaluation for energy planning and policy development

    International Nuclear Information System (INIS)

    Chicco, Gianfranco; Mancarella, Pierluigi

    2007-01-01

    Trigeneration or combined heat, cooling and power (CHCP) is becoming an increasingly important energy option, particularly on a small-scale basis (below 1 MW e ), with several alternatives nowadays available for the cooling power production and the coupling to cogeneration systems. This paper deals with the introduction of a suitable framework for assessing the energy saving performance of trigeneration alternatives, orientated towards energy planning studies and the development of regulatory policies. In particular, a new generalized performance indicator-the trigeneration primary energy saving (TPES)-is introduced and discussed, with the aim of effectively evaluating the primary energy savings from different CHCP alternatives. The potential of the TPES indicator is illustrated through specific analyses run over different combinations of trigeneration equipment, providing numerical examples based on time-domain simulations to illustrate the dependence of the energy saving characteristics on the CHCP system configurations and equipment, as well as on the loading levels. In addition, the key aspect of adequately establishing the reference efficiencies for the conventional separate production of electrical, thermal and cooling power is addressed in detail. This aspect affects both equipment selection and potential profitability of the considered solutions under the outlook of receiving financial incentives

  3. Evolution strategy based optimal chiller loading for saving energy

    International Nuclear Information System (INIS)

    Chang, Y.-C.; Lee, C.-Y.; Chen, C.-R.; Chou, C.-J.; Chen, W.-H.; Chen, W.-H.

    2009-01-01

    This study employs evolution strategy (ES) to solve optimal chiller loading (OCL) problem. ES overcomes the flaw that Lagrangian method is not adaptable for solving OCL as the power consumption models or the kW-PLR (partial load ratio) curves include convex functions and concave functions simultaneously. The complicated process of evolution by the genetic algorithm (GA) method for solving OCL can also be simplified by the ES method. This study uses the PLR of chiller as the variable to be solved for the decoupled air conditioning system. After analysis and comparison of the case study, it has been concluded that this method not only solves the problems of Lagrangian method and GA method, but also produces results with high accuracy within a rapid timeframe. It can be perfectly applied to the operation of air conditioning systems

  4. Cognitive strategies in the mental rotation task revealed by EEG spectral power.

    Science.gov (United States)

    Gardony, Aaron L; Eddy, Marianna D; Brunyé, Tad T; Taylor, Holly A

    2017-11-01

    The classic mental rotation task (MRT; Shepard & Metzler, 1971) is commonly thought to measure mental rotation, a cognitive process involving covert simulation of motor rotation. Yet much research suggests that the MRT recruits both motor simulation and other analytic cognitive strategies that depend on visuospatial representation and visual working memory (WM). In the present study, we investigated cognitive strategies in the MRT using time-frequency analysis of EEG and independent component analysis. We scrutinized sensorimotor mu (µ) power reduction, associated with motor simulation, parietal alpha (pα) power reduction, associated with visuospatial representation, and frontal midline theta (fmθ) power enhancement, associated with WM maintenance and manipulation. µ power increased concomitant with increasing task difficulty, suggesting reduced use of motor simulation, while pα decreased and fmθ power increased, suggesting heightened use of visuospatial representation processing and WM, respectively. These findings suggest that MRT performance involves flexibly trading off between cognitive strategies, namely a motor simulation-based mental rotation strategy and WM-intensive analytic strategies based on task difficulty. Flexible cognitive strategy use may be a domain-general cognitive principle that underlies aptitude and spatial intelligence in a variety of cognitive domains. We close with discussion of the present study's implications as well as future directions. Published by Elsevier Inc.

  5. Energy Smart Guide to Campus Cost Savings: Today's Trends in Project Finance, Clean Fuel Fleets, Combined Heat& Power, Emissions Markets

    Energy Technology Data Exchange (ETDEWEB)

    2003-07-01

    The Energy Smart Guide to Campus Cost Savings covers today's trends in project finance, combined heat& power, clean fuel fleets and emissions trading. The guide is directed at campus facilities and business managers and contains general guidance, contact information and case studies from colleges and universities across the country.

  6. Saving, efficiency and management of electric sector demand

    International Nuclear Information System (INIS)

    Sanchez de Tembleque, L. J.

    2007-01-01

    Spanish economic model of development is based on energy consumption, and its main source is imported fossil fuels, which have some environmental and scarcity consequences in the mid term, among others. These problems could be reduced in two ways: economic activity reduction or energy efficiency improvement. In the presence of these possibilities, It may be desirable to bet for saving and energy efficiency, to maintain the economic development. This assignment analyzes the main available regulatory and social mechanisms to promote saving and energy efficiency in the power sector, like systems to internalize social costs in the electricity price, efficiency standards, and encourage the new saving culture. (Author) 15 refs

  7. Purchasing Power and Purchasing Strategies - Insights From the Humanitarian Sector

    OpenAIRE

    Pazirandeh, Ala

    2014-01-01

    In this dissertation, we discuss how buyers practice purchasing strategies in an asymmetric power situation favoring suppliers, and how their purchasing strategies practiced impact their purchasing power and buyer-supplier relationships. Organizations enter exchange relationships to access required resources not produced internally, and are exposed to uncertainty from not being able to fully control or predict flow of resources. Consequently they become dependent on their partners. Their leve...

  8. Comparison of Power Control Strategies for DFIG Wind Turbines

    DEFF Research Database (Denmark)

    Teodorescu, Remus; Luna, A.; Rodríguez, P.

    2008-01-01

    The classical control techniques for regulating the active and reactive power delivery in doubly fed induction generators (DFIG), for wind power applications, are normally based on voltage oriented control (VOC) strategies. Among these algorithms, those that work in a synchronous reference frame...... VOC strategy able to control the operation of a DFIG in the αβ reference frame, with no need of flux position estimation, something that conducts to a more simple and robust algorithm. In order to evaluate the advantages of this new control proposal, namely VOC-RRF, their performance will be compared...

  9. Consumers’ perceptions of energy use and energy savings: A literature review

    Science.gov (United States)

    Lesic, Vedran; Bruine de Bruin, Wändi; Davis, Matthew C.; Krishnamurti, Tamar; Azevedo, Inês M. L.

    2018-03-01

    Background. Policy makers and program managers need to better understand consumers’ perceptions of their energy use and savings to design effective strategies for promoting energy savings. Methods. We reviewed 14 studies from the emerging interdisciplinary literature examining consumers’ perceptions electricity use by specific appliances, and potential savings. Results. We find that: (1) electricity use is often overestimated for low-energy consuming appliances, and underestimated for high-energy consuming appliances; (2) curtailment strategies are typically preferred over energy efficiency strategies; (3) consumers lack information about how much electricity can be saved through specific strategies; (4) consumers use heuristics for assessing the electricity use of specific appliances, with some indication that more accurate judgments are made among consumers with higher numeracy and stronger pro-environmental attitudes. However, design differences between studies, such as variations in reference points, reporting units and assessed time periods, may affect consumers’ reported perceptions. Moreover, studies differ with regard to whether accuracy of perceptions was evaluated through comparisons with general estimates of actual use, self-reported use, household-level meter readings, or real-time smart meter readings. Conclusion. Although emerging findings are promising, systematic variations in the measurement of perceived and actual electricity use are potential cause for concern. We propose avenues for future research, so as to better understand, and possibly inform, consumers’ perceptions of their electricity use. Ultimately, this literature will have implications for the design of effective electricity feedback for consumers, and related policies.

  10. Technical strategy map to employing nuclear power plant aging management

    International Nuclear Information System (INIS)

    Sekimura, Naoto; Kanno, Masanori

    2008-01-01

    Stated in this report are back ground of technical strategy map for nuclear power plant aging management, result of the first road map, significance of technical strategy map, introduction scenario, technology map, road map, upgrade in every year, three groups of academia, industry and government, plan of technical strategy map, upgrade system, comprehensive introduction scenario, measures of nuclear power plant aging management in Japan and the world, new inspection system, outline of 'technical strategy map 2008', preparation of technical information bases in industry, academia and government, collaboration of them, safety researches of neutron radiation damage, stress corrosion crack, fatigue, piping thinning, insulation degradation, concrete degradation, thermal aging, evaluation technologies of earthquake resistance, preparation of rules and standards, ideal maintenance, and training talent. (S.Y.)

  11. The carbon buster's home energy handbook : slowing climate change and saving money

    International Nuclear Information System (INIS)

    Stoyke, G.

    2007-01-01

    This book presented solutions for reducing household energy use and environmental impacts. It is intended for those who are concerned about global warming, rising fuel costs and environmental stewardship. It included practical suggestions and clearly explained measures that can help an individual reduce their greenhouse gas emissions and save money on energy bills. It listed best choices that individuals can make to contribute to a more sustainable world by reducing their carbon footprint. In addition to providing tips for saving energy and money, the book provided tools to weigh various energy efficiency options. It focused on products and technologies that can solve the problem of household contributions to the greenhouse gas problem by making good buying choices. It was shown that the intelligent use of appropriate technology can help avoid environmental problems. A detailed carbon accounting for a typical North American family's carbon emissions was presented along with strategies to reduce emissions by up to 73 per cent. The measures that yield the highest return for the environment and the wallet were evaluated. For example, the effectiveness of solar panels versus buying a hybrid car was measured, along with the cost in buying a $500 fridge that uses 800 kWh of power per year. The Carbon Buster strategies described in this book have an average annual return of 32 per cent. refs., tabs., figs

  12. Sierra Leone : Power Sector Recovery Strategy, Phase I

    OpenAIRE

    World Bank

    2007-01-01

    Power Planning Associates has been appointed by the World Bank to prepare a strategy for the recovery of the National Power Authority (NPA). This Preliminary Report presents the findings of the audit and proposes potential counter measures to improve NPA s technical and financial performance. These counter measures are presented at the end of each section of the report and are summarised...

  13. Next-generation reactors in the national energy strategy

    International Nuclear Information System (INIS)

    McGoff, D.J.

    1991-01-01

    In February 1991, the Bush Administration released the National Energy Strategy designed to provide an adequate and balanced energy supply. The strategy provides for major increases in energy efficiency and conservation. Even with these savings, however, there will be a need for substantial increases in base-load electrical generating capacity to sustain economic growth. The strategy identifies the actions required to allow nuclear power to cleanly and safely meet a substantial portion of this needed additional base-load capacity after the turn of the century. On June 27, 1991, the US Department of Energy (DOE) transmitted to Congress the Strategic Plan for Civilian Reactor Development, which reflects the initiative identified in the National Energy Strategy. The strategic plan identifies the advanced light water reactor (ALWR) as the basis for expanded use of nuclear power. The second advanced reactor concept that is being pursued is the modular high-temperature gas-cooled reactor (MHTGR)

  14. Strategies of development of European power producers

    International Nuclear Information System (INIS)

    Heddebaut, D.

    2007-12-01

    This economical study answers the following questions: what is the dynamics of European power markets? What is the relative competitiveness of the different power production means? What are the determining factors of electricity wholesale prices? Who are the operators the most threatened by the rise of wholesale prices? To what extend power producers are impacted by the CO 2 constrain? Who are the most efficient producers? The analysis is based on 18 of the most representative groups of the European electric utilities. The first volume of the study presents the strategic perspectives of European power producers: dynamics and basic characteristics of European power markets, strategic options of European operators, typology and financial results of European power producers, scenarios of market reorganization according to Eurostaf (possible mega-mergers in the future, competition). Volume 2 makes a detailed analysis of the positioning and perspectives of the 18 selected groups: key figures, sourcing strategies, production means management, Eurostaf's diagnosis. (J.S.)

  15. Stochastic Optimal Wind Power Bidding Strategy in Short-Term Electricity Market

    DEFF Research Database (Denmark)

    Hu, Weihao; Chen, Zhe; Bak-Jensen, Birgitte

    2012-01-01

    Due to the fluctuating nature and non-perfect forecast of the wind power, the wind power owners are penalized for the imbalance costs of the regulation, when they trade wind power in the short-term liberalized electricity market. Therefore, in this paper a formulation of an imbalance cost...... minimization problem for trading wind power in the short-term electricity market is described, to help the wind power owners optimize their bidding strategy. Stochastic optimization and a Monte Carlo method are adopted to find the optimal bidding strategy for trading wind power in the short-term electricity...... market in order to deal with the uncertainty of the regulation price, the activated regulation of the power system and the forecasted wind power generation. The Danish short-term electricity market and a wind farm in western Denmark are chosen as study cases due to the high wind power penetration here...

  16. FORMULATION STRATEGY UNDER THE INFLUENCE OF POWER COMPETITION

    Directory of Open Access Journals (Sweden)

    Ljiljana Stošić Mihajlović

    2014-10-01

    Full Text Available In this work, the subject of the research is defined starting hypothesis that formulation in the form of answers to the question: What factors - competitive forces shape strategy? Strategy formulation essentially boils down to competition. Competitors are all - customers, suppliers, potential new entrants to the market and producers of substitutes - and depending on the industry, may be more or less important or active. The first primary determinant of a firm's profitability is the attractiveness of the system to which it belongs. Competitive strategy must be developed from the basic knowledge of the rules of competition that determine the attractiveness of an economic system. The ultimate aim of competitive strategy is to apply, or - ideally - a change these rules in favor of the company. In any economic system, regardless of Whether it is domestic or international, and Whether products or services, the rules of competition are embodied in five competitive factors, the five basic forces: the entry of new competitors into the market, the threat of substitution, bargaining power of the buyer, bargaining power of suppliers and rivalry among existing competitors. Joint strength of these forces determines the ultimate potential of an activity to make a profit.

  17. Knowledge preservation strategies for nuclear power plants

    International Nuclear Information System (INIS)

    Koruna, S.; Bachmann, H.

    2004-01-01

    The nuclear industry is currently facing several challenges. An internal threat to the safety and operations of nuclear power plants is the loss of those employees who hold knowledge that is either critical to operations or safety. This report discusses the possibilities to preserve knowledge in nuclear power plants. Dependent on the degree of tacitness two different knowledge preservation strategies can be discerned: personalization and codification. The knowledge preservation activities discussed are valued according to the criteria: cost, immediacy of availability and completeness

  18. Private savings and financial modernization in Mexico, 1988-95

    Directory of Open Access Journals (Sweden)

    Julio Lopez G.

    2000-09-01

    Full Text Available The evolution of private savings has attracted a lot of attention in the controversy about the origins of Mexico's 1995 crisis. In this paper the authors analyze the evolution of private savings in Mexico using the theory of effective demand as a framework and making use of econometric estimates. In this context, they analyze the impact of the financial reforms, and in particular the effect of liberalization and deregulation of the financial system on private savings in Mexico from 1980 to 1995. The authors formulate an explanation of the determinants of private savingsand the impact of the strategy of "financial modernization" on private savings, by specifying a model that allows to identify the influence of monetary and credit policies on savings. Then they carry out econometric estimates that lend empirical support to the main conclusions of the theoretical analysis. Their econometric work confirm notably that private savings has been low due to a series of changes in monetary policy that favored the contraction of private demand and led to greater foreign indebtedness.

  19. Optimizing Energy Savings from Direct-DC in U.S. Residential Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Garbesi, Karina; Vossos, Vagelis; Sanstad, Alan; Burch, Gabriel

    2011-10-13

    An increasing number of energy efficient appliances operate on direct current (DC) internally, offering the potential to use DC from renewable energy systems directly and avoiding the losses inherent in converting power to alternating current (AC) and back. This paper investigates that potential for net-metered residences with on-site photovoltaics (PV) by modeling the net power draw of the ‘direct-DC house’ with respect to today’s typical configuration, assuming identical DC-internal loads. Power draws were modeled for houses in 14 U.S. cities, using hourly, simulated PV-system output and residential loads. The latter were adjusted to reflect a 33% load reduction, representative of the most efficient DC-internal technology, based on an analysis of 32 electricity end-uses. The model tested the effect of climate, electric vehicle (EV) loads, electricity storage, and load shifting on electricity savings; a sensitivity analysis was conducted to determine how future changes in the efficiencies of power system components might affect savings potential. Based on this work, we estimate that net-metered PV residences could save 5% of their total electricity load for houses without storage and 14% for houses with storage. Based on residential PV penetration projections for year 2035 obtained from the National Energy Modeling System (2.7% for the reference case and 11.2% for the extended policy case), direct-DC could save the nation 10 trillion Btu (without storage) or 40 trillion Btu (with storage). Shifting the cooling load by two hours earlier in the day (pre-cooling) has negligible benefits for energy savings. Direct-DC provides no energy savings benefits for EV charging, to the extent that charging occurs at night. However, if charging occurred during the day, for example with employees charging while at work, the benefits would be large. Direct-DC energy savings are sensitive to power system and appliance conversion efficiencies but are not significantly

  20. Way to save nuclear power

    International Nuclear Information System (INIS)

    Brightsen, R.A.

    1979-01-01

    In the opinion of many citizens, including the majority of those who oppose it, nuclear power will never recover from the 1979 accident at Three Mile Island. But some of nuclear power's supporters hope that the accident will shatter past smugness and spur constructive self-criticism on the part of the companies that build reactors, the utilities that buy them, and the Federal regulators who oversee their operation--and that it will usher in an era of truly safe atomic electricity. The article reviews deficiencies of the existing nuclear regulation - industry framework, and what must be done

  1. EFFECTIVE MANAGEMENT CONCEPT OF POWER CONSUMPTION OF INDUSTRIAL ENTERPRISE

    Directory of Open Access Journals (Sweden)

    Vladimir A. Koksharov

    2014-01-01

    Full Text Available The article distinguishes the methodological and systematic fundamentals for the formation of energy policy of the industrial enterprise. The article performes the analysis of Russian state policy in the field of energy efficiency and conservation , which allows to identify the organizational-economic and regulatory drawbacks proving the existing contradiction between the economic interests of the state and private business in the field of energy efficiency and power supply. Author proposes and formulates the management concept of power consumption of industrial enterprise. The concept includes a number of propositions, the dynamic normal of energy efficiency and energy saving playing the key role. It is regarded as a business model of energy efficiency and energy saving that provides the implementation of both economic and energetic strategies of enterprise.

  2. Natural gas decompression energy recovery: Energy savings potential in Italy

    International Nuclear Information System (INIS)

    Piatti, A.; Piemonte, C.; Rampini, E.; Vatrano, F.; Techint SpA, Milan; ENEA, Rome

    1992-01-01

    This paper surveyed the natural gas distribution systems employed in the Italian civil, industrial and thermoelectric sectors to identify those installations which can make use of gas decompression energy recovery systems (consisting of turbo-expanders or alternative expanders) to economically generate electric power. Estimates were then made of the total amount of potential energy savings. The study considered as eligible for energy savings interventions only those plants with a greater than 5,000 standard cubic meter per hour plant capacity. It was evaluated that, with suitable decompression equipment installed at 50 key installations (33 civil, 15 industrial), about 200 GWh of power could be produced annually, representing potential savings of about 22,000 petroleum equivalent tonnes of energy. A comparative analysis was done on three investment alternatives involving inputs of varying amounts of Government financial assistance

  3. Possibilities of using thermal mass in buildings to save energy, cut power consumption peaks and increase the thermal comfort

    OpenAIRE

    Karlsson, Jonathan

    2012-01-01

    The aim of this project was to generate knowledge to enable us to take advantage of heat storage in heavy building structures with regard to as energy savings, better thermal indoor climate, and reduced peak powers. This could include buildings that can function without energy input during cold periods, buildings that give a robust indoor climate without installed cooling, and buildings with good thermal comfort also in case of higher outdoor temperatures resulting from global warming. To rea...

  4. Retirement savings and decision errors: lessons from behavioral economics

    OpenAIRE

    Philip Armour; Mary C. Daly

    2008-01-01

    Long gone are the days when most American workers could rely on their employers to manage their retirement savings. Today, most people handle their retirement portfolios themselves, gaining the right and responsibility to determine their own best strategies. Research on retirement planning suggests, however, that many fall short of consensus targets for optimal savings and investment. While part of the shortfall is explained by information gaps and income constraints, research in behavioral e...

  5. Delta Power Control Strategy for Multi-String Grid-Connected PV Inverters

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Blaabjerg, Frede

    2016-01-01

    With a still increasing penetration level of grid-connected PV systems, more advanced active power control functionalities have been introduced in certain grid regulations. A delta power constraint, where a portion of the active power from the PV panels is reserved during operation, is required...... for grid support (e.g., during frequency deviation). In this paper, a cost-effective solution to realize delta power control for grid-connected PV systems is presented, where the residential/commercial multi-string PV inverter configuration is adopted. This control strategy is a combination of Maximum...... for the entire PV system is achieved. Simulations and experiments have been performed on a 3-kW single-phase grid-connected PV system. The results have confirmed the effectiveness of the delta power control strategy, where the power reserve according to the delta power constraint is achieved under several...

  6. Is Exercise Stress Testing a Cost-Saving Strategy For Risk Assessment of Pediatric Wolff-Parkinson-White Syndrome Patients?

    Science.gov (United States)

    Moltedo, Jose M.; Iyer, Ramesh V.; Forman, Howard; Fahey, John; Rosenthal, Geoffrey; Snyder, Christopher S.

    2006-01-01

    Background: In Wolff-Parkinson-White syndrome (WPW) patients the loss of pre-excitation in a single heartbeat during exercise stress testing (EST) is a predictor of low risk of sudden death. The purpose of this study was to: 1) assess the frequency of loss of pre-excitation in a single heartbeat during exercise testing, and 2) compare the cost of EST versus trans-catheter electrophysiology study (EPS) in the risk assessment of WPW patients. Methods: A retrospective review of 50 cases of patients with WPW who underwent EST was conducted including demographics, history of supraventricular tachycardia, associated congenital heart disease, maximum heart rate achieved, and loss of pre-excitation in a single heartbeat. Hospital costs of EST and EPS were compared. Results: Of the 50 patients who underwent EST, 4 (8%), lost pre-excitation in a single heartbeat during EST. No differences were found regarding gender, age at diagnosis or EST, history of supraventricular tachycardia, presence of congenital heart disease or maximal heart rate. A cost comparison, utilizing the cost data: EST ($62.75) and EPS ($5,597) found EST to be a cost-saving approach in WPW patients. With 4 patients losing pre-excitation during EST, the cost saving of EST was $22,388 for this population of WPW patients. Conclusions: A frequency of 8% loss of pre-excitation was found in a pediatric sample that underwent EST. Additionally, EST was shown to be a cost-saving strategy in risk assessment of pediatric WPW patients. PMID:21845141

  7. Reactive Power Injection Strategies for Single-Phase Photovoltaic Systems Considering Grid Requirements

    DEFF Research Database (Denmark)

    Yang, Yongheng; Wang, Huai; Blaabjerg, Frede

    2014-01-01

    .g. Germany and Italy. Those advanced features can be provided by next generation PV systems, and will be enhanced in the future to ensure an even efficient and reliable utilization of PV systems. In light of this, Reactive Power Injection (RPI) strategies for single-phase PV systems are explored...... in this paper. The RPI possibilities are: a) constant average active power control, b) constant active current control, c) constant peak current control and d) thermal optimized control strategy. All those strategies comply with the currently active grid codes, but are with different objectives. The proposed...... RPI strategies are demonstrated firstly by simulations and also tested experimentally on a 1 kW singe-phase grid-connected system in LVRT operation mode. Those results show the effectiveness and feasibilities of the proposed strategies with reactive power control during LVRT operation. The design...

  8. Dynamic multi-stage dispatch of isolated wind–diesel power systems

    International Nuclear Information System (INIS)

    Hu, Yu; Morales, Juan M.; Pineda, Salvador; Sánchez, María Jesús; Solana, Pablo

    2015-01-01

    Highlights: • Optimal decision-making model for isolated hybrid wind–diesel power system is proposed. • Wind power uncertainty and conditional operating cost are considered. • Battery wear cost of the energy storage system is included in the model. • The results are compared with deterministic dispatch strategies. - Abstract: An optimal dispatch strategy is crucial for an isolated wind–diesel power system to save diesel fuel and maintain the system stability. The uncertainty associated with the stochastic character of the wind is, though, a challenging problem for this optimization. In this paper, a dynamic multi-stage decision-making model is proposed to determine the diesel power output that minimizes the cost of running and maintaining the wind–diesel power system. Optimized operational decisions for each time period are generated dynamically considering the path-dependent nature of the optimal dispatch policy, given the plausible future realizations of the wind power production. A numerical case study is analyzed and it is demonstrated that the proposed stochastic dynamic optimization model significantly outperforms the traditional deterministic dispatch strategies

  9. Can global warming save nuclear power?

    International Nuclear Information System (INIS)

    Pearce, D.

    1994-01-01

    Nuclear powered electricity generation in the United Kingdom has an uncertain future. The relative costs of generating electricity by nuclear fission compared to other means and the need for a desirable mixture or ''portfolio'' of energy sources in the electricity industry are identified as the key to this uncertainty. The author argues that Government commitments to reducing Carbon Monoxide (CO) emissions, and hence global warming, may strengthen arguments in favour of a firm commitment to nuclear power, as even modern fossil-fuelled power plants emit nearly 90 times as much CO as nuclear plants. (UK)

  10. A Free-Piston Linear Generator Control Strategy for Improving Output Power

    Directory of Open Access Journals (Sweden)

    Chi Zhang

    2018-01-01

    Full Text Available This paper presents a control strategy to improve the output power for a single-cylinder two-stroke free-piston linear generator (FPLG. The comprehensive simulation model of this FPLG is established and the operation principle is introduced. The factors that affect the output power are analyzed theoretically. The characteristics of the piston motion are studied. Considering the different features of the piston motion respectively in acceleration and deceleration phases, a ladder-like electromagnetic force control strategy is proposed. According to the status of the linear electric machine, the reference profile of the electromagnetic force is divided into four ladder-like stages during one motion cycle. The piston motions, especially the dead center errors, are controlled by regulating the profile of the electromagnetic force. The feasibility and advantage of the proposed control strategy are verified through comparison analyses with two conventional control strategies via MatLab/Simulink. The results state that the proposed control strategy can improve the output power by around 7–10% with the same fuel cycle mass.

  11. A new self-scheduling strategy for integrated operation of wind and pumped-storage power plants in power markets

    International Nuclear Information System (INIS)

    Varkani, Ali Karimi; Daraeepour, Ali; Monsef, Hassan

    2011-01-01

    Highlights: → A strategy for integrated operation of wind and pumped-storage plants is proposed. → Participation of both plants in energy and ancillary service markets is modeled. → The uncertainty of wind production is modeled by a novel probabilistic function. → The proposed strategy is tested on a real case in the Spanish electricity market. -- Abstract: Competitive structure of power markets causes various challenges for wind resources to participate in these markets. Indeed, production uncertainty is the main cause of their low income. Thus, they are usually supported by system operators, which is in contrast with the competitive paradigm of power markets. In this paper, a new strategy for increasing the profits of wind resources is proposed. In the suggested strategy, a Generation Company (GenCo), who owns both wind and pumped-storage plants, self-schedules the integrated operation of them regarding the uncertainty of wind power generation. For presenting an integrated self-schedule and obtaining a real added value of the strategy, participation of the GenCo in energy and ancillary service markets is modeled. The self-scheduling strategy is based on stochastic programming techniques. Outputs of the problem include generation offers in day-ahead energy market and ancillary service markets, including spinning and regulation reserve markets. A Neural Network (NN) based technique is used for modeling the uncertainty of wind power production. The proposed strategy is tested on a real wind farm in mainland, Spain. Moreover, added value of the strategy is presented in different conditions of the market.

  12. Forward Link Power Control Strategy and its Optimum Issue in CDMA Cellular Networks

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    In this paper, we propose a theoretical method in order to estimate the forward link outage probability and user capacity of a cellular system which are based on IS-95 CDMA standard, especialy impact of power control strategy and voice activity monitoring in the system under long-term fading effects, in which the light and heavy fadings are considered. According to the numerical results obtained in this paper, the power control strategy leads to approximately the threefold user capacity in contrast to the situation without power control strategy. The reults are compared with Interference-to-Signal Ratio (ISR) driven power control scheme[6][9] which can be used only for simulation of the system. The power control strategy not only improves the desired signal to the interference ratio in the reference user's receiver, but also offers uniform service to the user wherever it is located in the cell.

  13. Net fossil energy savings for alternative mixes in various electric supply systems

    International Nuclear Information System (INIS)

    Essam, P.; Stocks, K.J.

    1978-11-01

    The actual and projected electric power station building programs of several countries and regions have been examined to determine what effect the introduction of nuclear power has on fossil fuel usage by the electricity system. It was found that (1) nuclear power leads directly to savings in fossil fuel usage, a larger nuclear component leading to larger savings; (2) individual nuclear stations rapidly wipe out the energy 'debt' incurred during building; and (3) the relatively short periods of consolidation in the early stages of a nation's building program usually prevent the nuclear component from going into energy 'debt'. Assessments of the energy requirements to build and run various types of power station have been made from the available literature

  14. Saving energy resources during heat treatment - the most important problem of the branch

    Energy Technology Data Exchange (ETDEWEB)

    Zadernovskiy, V V; Firger, I V

    1980-01-01

    Natural gas fired thermal furnaces expend significantly less fuel than electric furnaces with an equal quality of metal heating. An important reserve in power reserve economy is the use of the forging heat in an article for heat treatment (TOB), where besides the power resources, metal is also saved as a result of the reduction in the volume of heating means and production spaces. From the experience in the progressive enterprises of the branch, in a number of cases it is possible to combine heating for plastic deformation with heating for primary or secondary heat treatment. Other measures are examined which save power resources in heat treatment: the use of thermal furnaces for aerodynamic heating, the use of local heat treatment, the reduction in the duration of the heat treatment processes, savings in the power carriers during heat treatment in furnaces with a roll out hearth. Fibrous refractory materials are being used more and more as fettling materials in the construction of thermal furnaces.

  15. An energy-saving nonlinear position control strategy for electro-hydraulic servo systems.

    Science.gov (United States)

    Baghestan, Keivan; Rezaei, Seyed Mehdi; Talebi, Heidar Ali; Zareinejad, Mohammad

    2015-11-01

    The electro-hydraulic servo system (EHSS) demonstrates numerous advantages in size and performance compared to other actuation methods. Oftentimes, its utilization in industrial and machinery settings is limited by its inferior efficiency. In this paper, a nonlinear backstepping control algorithm with an energy-saving approach is proposed for position control in the EHSS. To achieve improved efficiency, two control valves including a proportional directional valve (PDV) and a proportional relief valve (PRV) are used to achieve the control objectives. To design the control algorithm, the state space model equations of the system are transformed to their normal form and the control law through the PDV is designed using a backstepping approach for position tracking. Then, another nonlinear set of laws is derived to achieve energy-saving through the PRV input. This control design method, based on the normal form representation, imposes internal dynamics on the closed-loop system. The stability of the internal dynamics is analyzed in special cases of operation. Experimental results verify that both tracking and energy-saving objectives are satisfied for the closed-loop system. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  16. Dynamic multi-stage dispatch of isolated wind–diesel power systems

    DEFF Research Database (Denmark)

    Hu, Yu; Morales González, Juan Miguel; Pineda, Salvador

    2015-01-01

    -stage decision-making model is proposed to determine the diesel power output that minimizes the cost of running and maintaining the wind–diesel power system. Optimized operational decisions for each time period are generated dynamically considering the path-dependent nature of the optimal dispatch policy, given......An optimal dispatch strategy is crucial for an isolated wind–diesel power system to save diesel fuel and maintain the system stability. The uncertainty associated with the stochastic character of the wind is, though, a challenging problem for this optimization. In this paper, a dynamic multi...

  17. Stand-alone excitation synchronous wind power generators with power flow management strategy

    Directory of Open Access Journals (Sweden)

    Tzuen-Lih Chern

    2014-09-01

    Full Text Available This study presents a stand-alone excitation synchronous wind power generator (SESWPG with power flow management strategy (PFMS. The rotor speed of the excitation synchronous generator tracks the utility grid frequency by using servo motor tracking technologies. The automatic voltage regulator governs the exciting current of generator to achieve the control goals of stable voltage. When wind power is less than the needs of the consumptive loading, the proposed PFMS increases motor torque to provide a positive power output for the loads, while keeping the generator speed constant. Conversely, during the periods of wind power greater than output loads, the redundant power of generator production is charged to the battery pack and the motor speed remains constant with very low power consumption. The advantage of the proposed SESWPG is that the generator can directly output stable alternating current (AC electricity without using additional DC–AC converters. The operation principles with software simulation for the system are described in detail. Experimental results of a laboratory prototype are shown to verify the feasibility of the system.

  18. Energy Management Strategies based on efficiency map for Fuel Cell Hybrid Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Feroldi, Diego; Serra, Maria; Riera, Jordi [Institut de Robotica i Informatica Industrial (CSIC-UPC), C. Llorens i Artigas 4, 08028 Barcelona (Spain)

    2009-05-15

    The addition of a fast auxiliary power source like a supercapacitor bank in fuel cell-based vehicles has a great potential because permits a significant reduction of the hydrogen consumption and an improvement of the vehicle efficiency. The Energy Management Strategies, commanding the power split between the power sources in the hybrid arrangement to fulfil the power requirement, perform a fundamental role to achieve this objective. In this work, three strategies based on the knowledge of the fuel cell efficiency map are proposed. These strategies are attractive due to the relative simplicity of the real time implementation and the good performance. The strategies are tested both in a simulation environment and in an experimental setup using a 1.2-kW PEM fuel cell. The results, in terms of hydrogen consumption, are compared with an optimal case, which is assessed trough an advantageous technique also introduced in this work and with a pure fuel cell vehicle as well. This comparative reveals high efficiency and good performance, allowing to save up to 26% of hydrogen in urban scenarios. (author)

  19. C. h. p. saves fuel in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Daugas, C F

    1979-04-01

    A combined heat and power plant based on a diesel generator to produce 12MW of electricity and 12MW of heat has successfully supplied the town of Skultuna in Sweden during the winter and has saved 3,700t of oil annually.

  20. Household Savings

    DEFF Research Database (Denmark)

    Browning, Martin; Lusardi, Annamaria

    suggested in the informal saving literature can be captured in the standard optimizing model. Particular attention is given to recent work on the precautionary motive and its implications for saving and consumption behavior. We also discuss the "behavioral" or "psychological" approach that eschews the use......In this survey, we review the recent theoretical and empirical literature on household saving and consumption. The discussion is structured around a list of motives for saving and how well the standard theory captures these motives. We show that almost all of the motives for saving that have been...

  1. Advanced power cycler with intelligent monitoring strategy of IGBT module under test

    DEFF Research Database (Denmark)

    Choi, U. M.; Blaabjerg, F.; Iannuzzo, F.

    2017-01-01

    and diode, which for the wear-out condition monitoring are presented. This advanced power cycler allows to perform power cycling test cost-effectively under conditions close to real power converter applications. In addition, an intelligent monitoring strategy for the separation of package-related wear......-out failure mechanisms has been proposed. By means of the proposed method, the wear-out failure mechanisms of an IGBT module can be separated without any additional efforts during the power cycling tests. The validity and effectiveness of the proposed monitoring strategy are also verified by experiments....

  2. Analysis of Application Power and Schedule Composition in a High Performance Computing Environment

    Energy Technology Data Exchange (ETDEWEB)

    Elmore, Ryan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Gruchalla, Kenny [National Renewable Energy Lab. (NREL), Golden, CO (United States); Phillips, Caleb [National Renewable Energy Lab. (NREL), Golden, CO (United States); Purkayastha, Avi [National Renewable Energy Lab. (NREL), Golden, CO (United States); Wunder, Nick [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-01-05

    As the capacity of high performance computing (HPC) systems continues to grow, small changes in energy management have the potential to produce significant energy savings. In this paper, we employ an extensive informatics system for aggregating and analyzing real-time performance and power use data to evaluate energy footprints of jobs running in an HPC data center. We look at the effects of algorithmic choices for a given job on the resulting energy footprints, and analyze application-specific power consumption, and summarize average power use in the aggregate. All of these views reveal meaningful power variance between classes of applications as well as chosen methods for a given job. Using these data, we discuss energy-aware cost-saving strategies based on reordering the HPC job schedule. Using historical job and power data, we present a hypothetical job schedule reordering that: (1) reduces the facility's peak power draw and (2) manages power in conjunction with a large-scale photovoltaic array. Lastly, we leverage this data to understand the practical limits on predicting key power use metrics at the time of submission.

  3. Defining a standard metric for electricity savings

    International Nuclear Information System (INIS)

    Koomey, Jonathan; Akbari, Hashem; Blumstein, Carl; Brown, Marilyn; Brown, Richard; Calwell, Chris; Carter, Sheryl; Cavanagh, Ralph; Chang, Audrey; Claridge, David; Craig, Paul; Diamond, Rick; Eto, Joseph H; Fulkerson, William; Gadgil, Ashok; Geller, Howard; Goldemberg, Jose; Goldman, Chuck; Goldstein, David B; Greenberg, Steve

    2010-01-01

    The growing investment by governments and electric utilities in energy efficiency programs highlights the need for simple tools to help assess and explain the size of the potential resource. One technique that is commonly used in this effort is to characterize electricity savings in terms of avoided power plants, because it is easier for people to visualize a power plant than it is to understand an abstraction such as billions of kilowatt-hours. Unfortunately, there is no standardization around the characteristics of such power plants. In this letter we define parameters for a standard avoided power plant that have physical meaning and intuitive plausibility, for use in back-of-the-envelope calculations. For the prototypical plant this article settles on a 500 MW existing coal plant operating at a 70% capacity factor with 7% T and D losses. Displacing such a plant for one year would save 3 billion kWh/year at the meter and reduce emissions by 3 million metric tons of CO 2 per year. The proposed name for this metric is the Rosenfeld, in keeping with the tradition among scientists of naming units in honor of the person most responsible for the discovery and widespread adoption of the underlying scientific principle in question-Dr Arthur H Rosenfeld.

  4. Defining a standard metric for electricity savings

    Energy Technology Data Exchange (ETDEWEB)

    Koomey, Jonathan [Lawrence Berkeley National Laboratory and Stanford University, PO Box 20313, Oakland, CA 94620-0313 (United States); Akbari, Hashem; Blumstein, Carl; Brown, Marilyn; Brown, Richard; Calwell, Chris; Carter, Sheryl; Cavanagh, Ralph; Chang, Audrey; Claridge, David; Craig, Paul; Diamond, Rick; Eto, Joseph H; Fulkerson, William; Gadgil, Ashok; Geller, Howard; Goldemberg, Jose; Goldman, Chuck; Goldstein, David B; Greenberg, Steve, E-mail: JGKoomey@stanford.ed

    2010-01-15

    The growing investment by governments and electric utilities in energy efficiency programs highlights the need for simple tools to help assess and explain the size of the potential resource. One technique that is commonly used in this effort is to characterize electricity savings in terms of avoided power plants, because it is easier for people to visualize a power plant than it is to understand an abstraction such as billions of kilowatt-hours. Unfortunately, there is no standardization around the characteristics of such power plants. In this letter we define parameters for a standard avoided power plant that have physical meaning and intuitive plausibility, for use in back-of-the-envelope calculations. For the prototypical plant this article settles on a 500 MW existing coal plant operating at a 70% capacity factor with 7% T and D losses. Displacing such a plant for one year would save 3 billion kWh/year at the meter and reduce emissions by 3 million metric tons of CO{sub 2} per year. The proposed name for this metric is the Rosenfeld, in keeping with the tradition among scientists of naming units in honor of the person most responsible for the discovery and widespread adoption of the underlying scientific principle in question-Dr Arthur H Rosenfeld.

  5. Defining a Standard Metric for Electricity Savings

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Marilyn; Akbari, Hashem; Blumstein, Carl; Koomey, Jonathan; Brown, Richard; Calwell, Chris; Carter, Sheryl; Cavanagh, Ralph; Chang, Audrey; Claridge, David; Craig, Paul; Diamond, Rick; Eto, Joseph H.; Fulkerson, William; Gadgil, Ashok; Geller, Howard; Goldemberg, Jose; Goldman, Chuck; Goldstein, David B.; Greenberg, Steve; Hafemeister, David; Harris, Jeff; Harvey, Hal; Heitz, Eric; Hirst, Eric; Hummel, Holmes; Kammen, Dan; Kelly, Henry; Laitner, Skip; Levine, Mark; Lovins, Amory; Masters, Gil; McMahon, James E.; Meier, Alan; Messenger, Michael; Millhone, John; Mills, Evan; Nadel, Steve; Nordman, Bruce; Price, Lynn; Romm, Joe; Ross, Marc; Rufo, Michael; Sathaye, Jayant; Schipper, Lee; Schneider, Stephen H; Sweeney, James L; Verdict, Malcolm; Vorsatz, Diana; Wang, Devra; Weinberg, Carl; Wilk, Richard; Wilson, John; Worrell, Ernst

    2009-03-01

    The growing investment by governments and electric utilities in energy efficiency programs highlights the need for simple tools to help assess and explain the size of the potential resource. One technique that is commonly used in this effort is to characterize electricity savings in terms of avoided power plants, because it is easier for people to visualize a power plant than it is to understand an abstraction such as billions of kilowatt-hours. Unfortunately, there is no standardization around the characteristics of such power plants. In this letter we define parameters for a standard avoided power plant that have physical meaning and intuitive plausibility, for use in back-of-the-envelope calculations. For the prototypical plant this article settles on a 500 MW existing coal plant operating at a 70percent capacity factor with 7percent T&D losses. Displacing such a plant for one year would save 3 billion kW h per year at the meter and reduce emissions by 3 million metric tons of CO2 per year. The proposed name for this metric is the Rosenfeld, in keeping with the tradition among scientists of naming units in honor of the person most responsible for the discovery and widespread adoption of the underlying scientific principle in question--Dr. Arthur H. Rosenfeld.

  6. REVIEW OF ENERGY-SAVING TECHNOLOGIES IN MODERN HYDRAULIC DRIVES

    Directory of Open Access Journals (Sweden)

    Mykola Karpenko

    2017-12-01

    Full Text Available This paper focuses on review of modern energy­saving technologies in hydraulic drives. Described main areas of energy conservation in hydraulic drive (which in turn are divided into many under the directions and was established the popularity of them. Reviewed the comparative analysis of efficiency application of various strategies for energy saving in a hydraulic drive. Based on the review for further research a combined method of real­time control systems with energy­saving algorithms and regeneration unit – selected for maxing efficiency in hydraulic drive. Scientific papers (40 papers, what introduced in review, is not older than 15 years in the databases “Sciencedirect” and “Scopus”.

  7. Cost savings through innovative technologies

    International Nuclear Information System (INIS)

    Lankford, J.M.; Jackson, J.P.

    1995-01-01

    Newly developed technologies can and already are saving money. Other technologies under development will provide solutions to problems which are currently impossible or too expensive to address, and still others will offer alternative strategies where baseline approaches are not acceptable to the public. All of these options will be considered as the nation decides what it wishes to accomplish, and fund, to clean up the nuclear weapons complex

  8. Operation of Modern Distribution Power Systems in Competitive Electricity Markets

    DEFF Research Database (Denmark)

    Hu, Weihao

    , DG units, loads and electricity price are studied. Further, the effect of energy storage systems will be considered, and an optimal operation strategy for energy storage devices in a large scale wind power system in the electricity market is proposed. The western Danish power system, which has large...... strategy for trading wind power in the Danish short-term electricity market in order to minimize the imbalance costs for regulation. A load optimization method based on spot price for demand side management in Denmark is proposed in order to save the energy costs for 3 types of typical Danish consumers...... maximum profit of the BESS is proposed. Two kinds of BESS, based on polysulfide-bromine (PSB) and vanadium redox (VRB) battery technologies, are studied. Optimal operation strategies of PEV in the spot market are then proposed in order to decrease the energy cost for PEV owners. Furthermore...

  9. A Single-Stage LED Tube Lamp Driver with Power-Factor Corrections and Soft Switching for Energy-Saving Indoor Lighting Applications

    Directory of Open Access Journals (Sweden)

    Chun-An Cheng

    2017-01-01

    Full Text Available This paper presents a single-stage alternating current (AC/direct current (DC light-emitting diode (LED tube lamp driver for energy-saving indoor lighting applications; this driver features power-factor corrections and soft switching, and also integrates a dual buck-boost converter with coupled inductors and a half-bridge series resonant converter cascaded with a bridge rectifier into a single-stage power-conversion topology. The features of the presented driver are high efficiency (>91%, satisfying power factor (PF > 0.96, low input-current total-harmonic distortion (THD < 10%, low output voltage ripple factor (<7.5%, low output current ripple factor (<8%, and zero-voltage switching (ZVS obtained on both power switches. Operational principles are described in detail, and experimental results obtained from an 18 W-rated LED tube lamp for T8/T10 fluorescent lamp replacements with input utility-line voltages ranging from 100 V to 120 V have demonstrated the functionality of the presented driver suitable for indoor lighting applications.

  10. Do You Automate? Saving Time and Dollars

    Science.gov (United States)

    Carmichael, Christine H.

    2010-01-01

    An automated workforce management strategy can help schools save jobs, improve the job satisfaction of teachers and staff, and free up precious budget dollars for investments in critical learning resources. Automated workforce management systems can help schools control labor costs, minimize compliance risk, and improve employee satisfaction.…

  11. Regulation strategies for wind power fluctuations depending on demand in Spain

    Energy Technology Data Exchange (ETDEWEB)

    Martin-Martinez, Sergio; Vigueras-Rodriguez, Antonio; Gomez-Lazaro, Emilio [Universidad de Castilla-La Mancha, Albacete (Spain). Energy Research Inst.; Fuentes, Juan Alvaro; Molina-Garcia, Angel [Cartagena Univ. (Spain). Dept. of Electrical Engineering

    2010-07-01

    Power systems need more flexibility as far as significant amounts of load are being covered by wind power. The variations of large wind power production impose some adverse effects on the power system. Some of these effects are the cycling losses on centralized units, discarded wind energy and increase of reserve requirements. Cycling losses derived from a non-optimal operation on great thermal and hydro power plants is an important issue produced by the stochastic wind power nature. Discarded wind energy is produced when the system can not assimilate all the wind power production. Reserve requirements are increased to keep the system balance with the secondary control. Different control functions have been developed for active power production. Some of them are balance control, delta control and power gradient limitation. Balance control consists in adjusting the production in steps to a set point constant production. The delta production constraint consists on limiting the current production to a fix delta power value below the possible production. This constraint is usually used for increasing the regulation capabilities in the wind farm. The Delta constraint can also be used jointly with the negative ramp limiting strategy, allowing then also to fix a maximum negative gradient for the cases in which the wind speed is decreasing and it is possible to limit that descend by reducing the delta value. The power gradient limiting strategy consists in a limitation of the maximum increasing gradient of the current production, i.e. it prevents the farm production from increasing too fast when the wind speed is rising or when the farm is to be started in high wind. It the wind speed is decreasing, then the constraint does not have any function. On the other hand, the negative ramp limiting strategy consists in a limitation of the maximum decreasing gradient of the current production. If the wind speed is increasing, then the constraint does not have any function. This

  12. Research on Control Strategy of Free-Piston Stirling Power Generating System

    Directory of Open Access Journals (Sweden)

    Jigui Zheng

    2017-10-01

    Full Text Available As a clean and fuel adaptive alternative power plant, the Stirling power generating system has drawn attention of experts and scholars in the energy field. In practical application, the instability of free-piston Stirling power generating system caused by abrupt load change is an inevitable problem. Thus, methods to improve the output frequency response and stability of the free-piston Stirling power generating system are necessary. The model of free-piston Stirling power generating system is built by isothermal analysis firstly, and the initial control strategy based on given voltage system is put forward. To further improve the performance of power system, a current feedback decoupling control strategy is proposed, and the mathematical model is established. The influence of full decoupled quadrature-direct (d-q axis currents is analyzed with respect to the output voltage adjusting time and fluctuation amplitude under the variations of piston displacement and output load. The simulation results show that the system performance is significantly improved, but the dynamic regulation lags caused by the decoupled current control still exist. To solve this problem and improve the performance of decoupled-state feedback current control that relies on parameter accuracy, internal model control based on sliding mode (IMC-SM current decoupling control strategy is proposed, the system model is established, and then the performance of voltage ripple in generating mode is improved. Finally, the test bench is built, and the steady state and transient voltage control performances are tested. The feasibility and priority of the control strategy is verified by experiment and simulation results.

  13. Saving in cycles: how to get people to save more money.

    Science.gov (United States)

    Tam, Leona; Dholakia, Utpal

    2014-02-01

    Low personal savings rates are an important social issue in the United States. We propose and test one particular method to get people to save more money that is based on the cyclical time orientation. In contrast to conventional, popular methods that encourage individuals to ignore past mistakes, focus on the future, and set goals to save money, our proposed method frames the savings task in cyclical terms, emphasizing the present. Across the studies, individuals who used our proposed cyclical savings method, compared with individuals who used a linear savings method, provided an average of 74% higher savings estimates and saved an average of 78% more money. We also found that the cyclical savings method was more efficacious because it increased implementation planning and lowered future optimism regarding saving money.

  14. Power plant instrumentation and control handbook a guide to thermal power plants

    CERN Document Server

    Basu, Swapan

    2014-01-01

    The book discusses instrumentation and control in modern fossil fuel power plants, with an emphasis on selecting the most appropriate systems subject to constraints engineers have for their projects. It provides all the plant process and design details, including specification sheets and standards currently followed in the plant. Among the unique features of the book are the inclusion of control loop strategies and BMS/FSSS step by step logic, coverage of analytical instruments and technologies for pollution and energy savings, and coverage of the trends toward filed bus systems and integratio

  15. Strategy Guideline: Mitigation of Retrofit Risk Factors

    Energy Technology Data Exchange (ETDEWEB)

    Berman, M.; Smith, P.; Porse, E.

    2012-12-01

    The Alliance for Residential Building Innovation (ARBI) is currently developing strategies designed to promote and achieve increased energy savings and promote upgrades in the residential retrofit sector. These strategies are targeted to retrofit program managers, retrofit contractors, policy makers, academic researchers, and non-governmental organizations. This report focuses on four key areas to promote home energy upgrades: fostering accurate energy savings projections; understanding consumer perceptions for energy savings; measuring energy savings, and ensuring quality control for retrofit installations.

  16. A New Generalized Discontinuous-PWM Strategy for Active Power Filters

    DEFF Research Database (Denmark)

    Asiminoaei, Lucian; Rodriguez, Pedro; Blaabjerg, Frede

    2007-01-01

    losses in any operating point. This paper proposes a new discontinuous pulse width modulation strategy applied to shunt active power filters. The proposed modulation strategy detects the current vector position relative to the inverter voltage reference and determines instantaneously the optimum clamped...

  17. A CLS-based survivable and energy-saving WDM-PON architecture

    Science.gov (United States)

    Zhu, Min; Zhong, Wen-De; Zhang, Zhenrong; Luan, Feng

    2013-11-01

    We propose and demonstrate an improved survivable and energy-saving WDM-PON with colorless ONUs. It incorporates both energy-saving and self-healing operations. A simple effective energy-saving scheme is proposed by including an energy-saving control unit in the OLT and a control unit at each ONU. The energy-saving scheme realizes both dozing and sleep (offline) modes, which greatly improves the energy-saving efficiency for WDM-PONs. An intelligent protection switching scheme is designed in the OLT, which can distinguish if an ONU is in dozing/sleep (offline) state or a fiber is faulty. Moreover, by monitoring the optical power of each channel on both working and protection paths, the OLT can know the connection status of every fiber path, thus facilitating an effective protection switching and a faster failure recovery. The improved WDM-PON architecture not only significantly reduces energy consumption, but also performs self-healing operation in practical operation scenarios. The scheme feasibility is experimentally verified with 10 Gbit/s downstream and 1.25 Gbit/s upstream transmissions. We also examine the energy-saving efficiency of our proposed energy-saving scheme by simulation, which reveals that energy saving mainly arises from the dozing mode, not from the sleep mode when the ONU is in the online state.

  18. Nuclear power development: global challenges and strategies

    International Nuclear Information System (INIS)

    Mourogov, Victor M.; )

    1997-01-01

    This article highlights key factors that will determine today and tomorrow's optimal energy strategies. It addresses methods to utilize the high potential energy content of uranium. Plutonium used as fuel in a nuclear reactors is discussed as is the future potential of a thorium fuel cycle. Various strategies to increase the economic viability of nuclear power are brought out. Technological means to further minimize environmental impacts and to enhance safety are covered as they are a major factor in public acceptance. Also covered are advances anticipated by mid-century in nuclear reactor and fuel cycle technologies

  19. Assessment of retinal sensitivity using a time-saving strategy in normal individuals

    Directory of Open Access Journals (Sweden)

    Suzumura H

    2012-11-01

    .Keywords: time-saving strategy, frequency-of-seeing curve, dynamic, Swedish Interactive Threshold Algorithm Standard, Octopus perimeter, Humphrey field analyzer

  20. Stakeholders’ influence on the adoption of energy-saving technologies in Italian homes

    International Nuclear Information System (INIS)

    Berardi, Umberto

    2013-01-01

    The instability and fragmentation of the temporary aggregations of many stakeholders in construction processes are barriers to adopting new technologies. This paper investigates the influence of different stakeholders on the adoption of mature energy-saving technologies in new residential buildings. Recent literature about the influence of different stakeholders on construction processes is reviewed focusing in their interest for energy saving technologies. To gain an insight into the specific roles played by stakeholders (general contractors, construction firms, architects, users and public governments) in different projects, a case study methodology was used. The influence on the adoption of energy-saving technologies of stakeholders was assessed through semi-structured interviews. These interviews focused on the interest and power for the adoption of several energy-saving technologies. Having recognized that the interest in adoption is often expressed late in the construction processes, the time of introduction of this interest was assessed. This paper provides an empirical insight into significant barriers for the adoption of energy saving technologies which are the low influence of highly motivated stakeholders on the decision of adoption, and the delay at which the interest in energy-saving technologies emerges. Finally, policies to overcome these barriers are suggested. - Highlights: • Why energy saving technologies are rarely adopted in buildings? • Diffusion is slowed by the late participation of stakeholders with great interest for energy technologies. • The influence of construction stakeholders for the adoption of energy saving technologies is measured in Italian case studies. • More integrated relationships among stakeholders are required to help the adoption of energy saving technologies. • Process re-organizations and policies which increase final users’ power are needed

  1. How to tackle energy saving and load leveling. Energy saving towards 2000 and measures for the coming winter (energy-saving activities by California`s SCE, demand side management activities); Sho energy fuka heijunka ni do torikumuka. Seireki 2000 nen ni muketa sho energy to konto no shoene taisaku, Kashu SCE no sho energy (DSM katsudo wo saguru)

    Energy Technology Data Exchange (ETDEWEB)

    Nasu, S. [The Energy Conservation Center Japan, Tokyo (Japan)

    1997-02-01

    Tokyo Electric Power has realized a peak shift of 5% for the maximum power demand by various measures to cope with increasing power demand and differential rate by time zone, including expansion of the differential rate system and heat-storage systems. Some of more notable recent techniques are eco-ice and eco-vendor systems, the former storing ice in the heat-storage tanks and the latter strongly cooling vending machines during nighttime. The NAS battery system is being developed as the new technique for load leveling. The energy-related advisory organ for Minister of International Trade and Industry asks each industrial unit to save at least 1% of power on the annual average as the energy-saving measure towards 2000. The energy-saving measures promoted by the government for the coming winter are controlled release of wastes, efficient use of power, setting room temperature at 19{degree}C or lower and voluntarily refrain from commuting by cars. The US power industry is abandoning the concept of DSM in the midst of deregulation and increased competition, and cutting budgets for new energy development. California`s SCE is promoting energy-saving through expanded use of high-efficiency motors, accurate grasp of customers` needs and publicity activities through internet systems. 4 figs., 1 tab.

  2. Comparison among nonlinear excitation control strategies used for damping power system oscillations

    International Nuclear Information System (INIS)

    Leon, A.E.; Solsona, J.A.; Valla, M.I.

    2012-01-01

    Highlights: ► A description and comparison of nonlinear control strategies for synchronous generators are presented. ► Advantages of using nonlinear controllers are emphasized against the use of classical PSSs. ► We find that a particular selection of IDA gains achieve the same performance that FL controllers. - Abstract: This work is focused on the problem of power system stability. A thorough description of nonlinear control strategies for synchronous generator excitation, which are designed for damping oscillations and improving transient stability on power systems, is presented along with a detailed comparison among these modern strategies and current solutions based on power system stabilizers. The performance related to damping injection in each controller, critical time enhancement, robustness against parametric uncertainties, and control signal energy consumption is analyzed. Several tests are presented to validate discussions on various advantages and disadvantages of each control strategy.

  3. Turbine Control Strategies for Wind Farm Power Optimization

    DEFF Research Database (Denmark)

    Mirzaei, Mahmood; Göçmen Bozkurt, Tuhfe; Giebel, Gregor

    2015-01-01

    In recent decades there has been increasing interest in green energies, of which wind energy is the most important one. In order to improve the competitiveness of the wind power plants, there are ongoing researches to decrease cost per energy unit and increase the efficiency of wind turbines...... and wind farms. One way of achieving these goals is to optimize the power generated by a wind farm. One optimization method is to choose appropriate operating points for the individual wind turbines in the farm. We have made three models of a wind farm based on three difference control strategies...... the generated power by changing the power reference of the individual wind turbines. We use the optimization setup to compare power production of the wind farm models. This paper shows that for the most frequent wind velocities (below and around the rated values), the generated powers of the wind farms...

  4. Energy/bandwidth-Saving Cooperative Spectrum Sensing for Two-hopWRAN

    Directory of Open Access Journals (Sweden)

    Ming-Tuo Zhou

    2014-07-01

    Full Text Available A two-hop wireless regional area network (WRAN providing monitoring services operating in Television White Space (TVWS, i.e., IEEE P802.22b, may employ a great number of subscriber customer-premises equipments (S-CPEs possibly without mains power supply, leading to requirement of cost-effective and power-saving design. This paper proposes a framework of cooperative spectrum sensing (CSS and an energy/bandwidth saving CSS scheme to P802.22b. In each round of sensing, S-CPEs with SNRs lower than a predefined threshold are excluded from reporting sensing results. Numerical results show that the fused missed-detection probability and false alarmprobability could remainmeeting sensing requirements, and the overall fused error probability changes very little. With 10 S-CPEs, it is possible to save more than 40% of the energy/bandwidth on a Rayleigh channel. The principle proposed can apply to other advanced sensing technologies capable of detecting primary signals with low average SNR.

  5. Strategy Design of Hybrid Energy Storage System for Smoothing Wind Power Fluctuations

    Directory of Open Access Journals (Sweden)

    Jingyu Liu

    2016-11-01

    Full Text Available With the increasing contribution of wind power plants, the reliability and security of modern power systems have become a huge challenge due to the uncertainty and intermittency of wind energy sources. In this paper, a hybrid energy storage system (HESS consisting of battery and supercapacitor is built to smooth the power fluctuations of wind power. A power allocation strategy is proposed to give full play to the respective advantages of the two energy storage components. In the proposed strategy, the low-frequency and high-frequency components of wind power fluctuations are absorbed by battery groups and supercapacitor groups, respectively. By inhibiting the low-frequency components of supercapacitor current, the times of charging-discharging of battery groups can be significantly reduced. A DC/AC converter is applied to achieve the power exchange between the HESS and the grid. Adjustment rules for regulating state-of-charge (SOC of energy storage elements are designed to avoid overcharge and deep discharge considering the safety and the high efficiency of the energy storage elements. Experimental results on the test platform verify the effectiveness of the proposed power allocation strategy in DC/AC converter and battery SOC adjustment rules for regulating SOC levels.

  6. Psychological interventions for energy saving. Development and evaluation of an electricity consumption reduction campaign in an urban development of energy-saving buildings; Energiesparen foerdern durch psychologische Intervention. Entwicklung und Evaluation einer Stromsparkampagne in einer Energiesparhaussiedlung

    Energy Technology Data Exchange (ETDEWEB)

    Mack, B.

    2007-07-01

    The study analyzes models of action of social psychology - in particular also an approach to institutionalize routine behaviour patterns - in order to identify the influencing factors that are described and the strategies for energy saving which are promoted. It also presents a comprehensive outline of current intervention studies and identifies effective strategy combinations which may serve as a basis for effective energy conservation campaigns. Against this background, an intervention measure for a neighbourhood context is developed and evaluated which is to promote energy-saving patterns of energy use in private households. The long-term effects suggest that it is a promising strategy to use a combination of information, commitment, goal identification, and individual and comparative feedback and to make use of group processes in a social context for developing energy-saving (routine) behaviour patterns. (orig.)

  7. Strategy Guideline. Mitigation of Retrofit Risk Factors

    Energy Technology Data Exchange (ETDEWEB)

    Berman, M. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Smith, P. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Porse, E. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2012-12-01

    The Alliance for Residential Building Innovation (ARBI) Building America team is currently developing strategies designed to promote and achieve increased energy savings and promote upgrades in the residential retrofit sector. These strategies are targeted to retrofit program managers, retrofit contractors, policy makers, academic researchers, and non-governmental organizations. This report focuses on four key areas to promote home energy upgrades: fostering accurate energy savings projections; understanding consumer perceptions for energy savings; measuring energy savings, and ensuring quality control for retrofit installations.

  8. A real time fuzzy logic power management strategy for a fuel cell vehicle

    International Nuclear Information System (INIS)

    Hemi, Hanane; Ghouili, Jamel; Cheriti, Ahmed

    2014-01-01

    Highlights: • We present a real time fuzzy logic power management strategy. • This strategy is applied to hybrid electric vehicle dynamic model. • Three configurations evaluated during a drive cycle. • The hydrogen consumption is analysed for the three configurations. - Abstract: This paper presents real time fuzzy logic controller (FLC) approach used to design a power management strategy for a hybrid electric vehicle and to protect the battery from overcharging during the repetitive braking energy accumulation. The fuel cell (FC) and battery (B)/supercapacitor (SC) are the primary and secondary power sources, respectively. This paper analyzes and evaluates the performance of the three configurations, FC/B, FC/SC and FC/B/SC during real time driving conditions and unknown driving cycle. The MATLAB/Simulink and SimPowerSystems software packages are used to model the electrical and mechanical elements of hybrid vehicles and implement a fuzzy logic strategy

  9. Power Management Strategy of Hybrid Electric Vehicles Based on Quadratic Performance Index

    Directory of Open Access Journals (Sweden)

    Chaoying Xia

    2015-11-01

    Full Text Available An energy management strategy (EMS considering both optimality and real-time performance has become a challenge for the development of hybrid electric vehicles (HEVs in recent years. Previous EMSes based on the optimal control theory minimize the fuel consumption, but cannot be directly implemented in real-time because of the requirement for a prior knowledge of the entire driving cycle. This paper presents an innovative design concept and method to obtain a power management strategy for HEVs, which is independent of future driving conditions. A quadratic performance index is designed to ensure the vehicle drivability, maintain the battery energy sustainability and average and smooth the engine power and motor power to indirectly reduce fuel consumption. To further improve the fuel economy, two rules are adopted to avoid the inefficient engine operation by switching control modes between the electric and hybrid modes according to the required driving power. The derived power of the engine and motor are related to current vehicle velocity and battery residual energy, as well as their desired values. The simulation results over different driving cycles in Advanced Vehicle Simulator (ADVISOR show that the proposed strategy can significantly improve the fuel economy, which is very close to the optimal strategy based on Pontryagin’s minimum principle.

  10. DCS upgrades for nuclear power plants: Saving money and reducing risk through virtual-stimulation control system checkout

    International Nuclear Information System (INIS)

    McKim, G.; Yeager, M.; Weirich, C.

    2006-01-01

    Nuclear power plant control systems of 1970's vintage have reached the end of their life: reliability is poor and spare parts are hard to come by. At First Energy Perry station, two costly feedwater system trips caused by an ailing analog control system led to the decision to replace it with a modern Foxboro I/A-series Distributed Control System. The simulator was also upgraded using the Virtual-Stim simulation of I/A, called FSIM. Virtual-Stim simulation allows the configuration and graphics from the plant to be downloaded onto the simulator as-is, using the same tools and operator interface as the plant, without imprecise translations, conversions, or other emulation. Advances in simulation technology and market forces have led to an open architecture design, allowing FSIM to be 'bridged' to Perry's existing Opensim simulator process model. This appears to be an industry-wide trend as more control system vendors offer Virtual Stimulation solutions for connection to third-party simulation products. Taking a cue from First Energy's Sammis Station FSIM simulator projects, the Perry simulator was used for dedicated control verification and tuning. Preventing forced outages caused by control configuration errors can result in enormous savings, and the simulator is now required to precede any plant modifications rather than just a training tool that lags the plant. This testing revealed several surprising results for a relatively straightforward control strategy, showing that simulator-based testing will be even more crucial in the future as the remain-der of the balance of plant is migrated to digital control. (author)

  11. Optimal Self-Tuning PID Controller Based on Low Power Consumption for a Server Fan Cooling System.

    Science.gov (United States)

    Lee, Chengming; Chen, Rongshun

    2015-05-20

    Recently, saving the cooling power in servers by controlling the fan speed has attracted considerable attention because of the increasing demand for high-density servers. This paper presents an optimal self-tuning proportional-integral-derivative (PID) controller, combining a PID neural network (PIDNN) with fan-power-based optimization in the transient-state temperature response in the time domain, for a server fan cooling system. Because the thermal model of the cooling system is nonlinear and complex, a server mockup system simulating a 1U rack server was constructed and a fan power model was created using a third-order nonlinear curve fit to determine the cooling power consumption by the fan speed control. PIDNN with a time domain criterion is used to tune all online and optimized PID gains. The proposed controller was validated through experiments of step response when the server operated from the low to high power state. The results show that up to 14% of a server's fan cooling power can be saved if the fan control permits a slight temperature response overshoot in the electronic components, which may provide a time-saving strategy for tuning the PID controller to control the server fan speed during low fan power consumption.

  12. Optimal Self-Tuning PID Controller Based on Low Power Consumption for a Server Fan Cooling System

    Directory of Open Access Journals (Sweden)

    Chengming Lee

    2015-05-01

    Full Text Available Recently, saving the cooling power in servers by controlling the fan speed has attracted considerable attention because of the increasing demand for high-density servers. This paper presents an optimal self-tuning proportional-integral-derivative (PID controller, combining a PID neural network (PIDNN with fan-power-based optimization in the transient-state temperature response in the time domain, for a server fan cooling system. Because the thermal model of the cooling system is nonlinear and complex, a server mockup system simulating a 1U rack server was constructed and a fan power model was created using a third-order nonlinear curve fit to determine the cooling power consumption by the fan speed control. PIDNN with a time domain criterion is used to tune all online and optimized PID gains. The proposed controller was validated through experiments of step response when the server operated from the low to high power state. The results show that up to 14% of a server’s fan cooling power can be saved if the fan control permits a slight temperature response overshoot in the electronic components, which may provide a time-saving strategy for tuning the PID controller to control the server fan speed during low fan power consumption.

  13. Rio Branco, grand strategy and naval power

    Directory of Open Access Journals (Sweden)

    João Paulo Alsina Jr.

    2014-12-01

    Full Text Available This article addresses Baron of Rio Branco's grand strategy and the role played by the naval reorganization program (1904-1910 in this context. The ensuing case study determined the domestic and international constraints that affected the program, as well as the worldview of the patron of Brazilian diplomacy regarding military power's instrumentality to foreign policy.

  14. Promoting energy-saving and environmentally friendly generation dispatching model in China: Phase development and case studies

    International Nuclear Information System (INIS)

    Ding, Yi; Yang, Hongliang

    2013-01-01

    Energy saving and environmental protection are important conditions for the sustainable development of Chinese economy. However current widely used generation scheduling model based on predefined production quota and tariff results in heavy energy consumption and severe environment pollution. From 2007, as concerns over energy shortage and environmental pollution, the Chinese authorities introduced the implementation of energy-saving generation dispatching model, which is an important approach to facilitating energy-saving and reduction of pollutant emission. The objective of implementing energy-saving generation dispatching model is to prioritize the use of renewable energy resources and new power plants with high efficiency without compromising power system security and reliability. This paper analyzes the necessity and feasibility of implementing energy-efficient and environmentally friendly generation scheduling models in China. The institutional and technical barriers impeding the implementation of energy-saving generation dispatching model are identified. The development of advanced energy-saving generation scheduling models towards competitive market models and phased planning programs are emphasized in this paper. The effectiveness and experience of provinces piloted energy-saving generation dispatching projects are also discussed. - Highlights: ► Introducing problems of current power generation scheduling model in China. ► Discussing necessity of implementing ESGD model and corresponding barriers. ► Proposing phased planning programs for developing ESGD models. ► Discussing the effectiveness and experience of provinces piloted ESGD projects

  15. Defining The Energy Saving Potential of Architectural Design

    DEFF Research Database (Denmark)

    Naboni, Emanuele; Malcangi, Antonio; Zhang, Yi

    2015-01-01

    Designers, in response to codes or voluntary " green building " programs, are increasingly concerned with building energy demand reduction, but they are not fully aware of the energy saving potential of architectural design. According to literature, building form, construction and material choices...... on sustainable design: " Design With Climate " by Olgyay (1963), which discussed strategies for climate-adapted architecture, and Lechner´s " Heating, Cooling and Lighting " (1991), on how to reduce building energy needs by as much as 60 – 80 percent with proper architectural design decisions. Both books used...... behaviour. The research shows the best solution for each of the climates and compares them with Olgyay´s findings. Finally, for each climate the energy saving potential is defined and then compared to Lechner's conclusions. Defining The Energy Saving Potential of Architectural Design (PDF Download Available...

  16. Statistical power of model selection strategies for genome-wide association studies.

    Directory of Open Access Journals (Sweden)

    Zheyang Wu

    2009-07-01

    Full Text Available Genome-wide association studies (GWAS aim to identify genetic variants related to diseases by examining the associations between phenotypes and hundreds of thousands of genotyped markers. Because many genes are potentially involved in common diseases and a large number of markers are analyzed, it is crucial to devise an effective strategy to identify truly associated variants that have individual and/or interactive effects, while controlling false positives at the desired level. Although a number of model selection methods have been proposed in the literature, including marginal search, exhaustive search, and forward search, their relative performance has only been evaluated through limited simulations due to the lack of an analytical approach to calculating the power of these methods. This article develops a novel statistical approach for power calculation, derives accurate formulas for the power of different model selection strategies, and then uses the formulas to evaluate and compare these strategies in genetic model spaces. In contrast to previous studies, our theoretical framework allows for random genotypes, correlations among test statistics, and a false-positive control based on GWAS practice. After the accuracy of our analytical results is validated through simulations, they are utilized to systematically evaluate and compare the performance of these strategies in a wide class of genetic models. For a specific genetic model, our results clearly reveal how different factors, such as effect size, allele frequency, and interaction, jointly affect the statistical power of each strategy. An example is provided for the application of our approach to empirical research. The statistical approach used in our derivations is general and can be employed to address the model selection problems in other random predictor settings. We have developed an R package markerSearchPower to implement our formulas, which can be downloaded from the

  17. Research on wind power grid-connected operation and dispatching strategies of Liaoning power grid

    Science.gov (United States)

    Han, Qiu; Qu, Zhi; Zhou, Zhi; He, Xiaoyang; Li, Tie; Jin, Xiaoming; Li, Jinze; Ling, Zhaowei

    2018-02-01

    As a kind of clean energy, wind power has gained rapid development in recent years. Liaoning Province has abundant wind resources and the total installed capacity of wind power is in the forefront. With the large-scale wind power grid-connected operation, the contradiction between wind power utilization and peak load regulation of power grid has been more prominent. To this point, starting with the power structure and power grid installation situation of Liaoning power grid, the distribution and the space-time output characteristics of wind farm, the prediction accuracy, the curtailment and the off-grid situation of wind power are analyzed. Based on the deep analysis of the seasonal characteristics of power network load, the composition and distribution of main load are presented. Aiming at the problem between the acceptance of wind power and power grid adjustment, the scheduling strategies are given, including unit maintenance scheduling, spinning reserve, energy storage equipment settings by the analysis of the operation characteristics and the response time of thermal power units and hydroelectric units, which can meet the demand of wind power acceptance and provide a solution to improve the level of power grid dispatching.

  18. Energy Saving Potential of PCMs in Buildings under Future Climate Conditions

    Directory of Open Access Journals (Sweden)

    Abdo Abdullah Ahmed Gassar

    2017-11-01

    Full Text Available Energy consumption reduction under changing climate conditions is a major challenge in buildings design, where excessive energy consumption creates an economic and environmental burden. Improving thermal performance of the buildings through support applying phase change material (PCM is a promising strategy for reducing building energy consumption under future climate change. Therefore, this study aims to investigate the energy saving potentials in buildings under future climate conditions in the humid and snowy regions in the hot continental and humid subtropical climates of the east Asia (Seoul, Tokyo and Hong Kong when various PCMs with different phase change temperatures are applied to a lightweight building envelope. Methodology in this work is implemented in two phases: firstly, investigation of energy saving potentials in buildings through inclusion of three types of PCMs with different phase temperatures into the building envelop separately and use weather file in the present (2017; and, secondly, evaluation of the effect of future climate change on the performance of PCMs by analyzing energy saving potentials of PCMs with 2020, 2050 and 2080 weather data. The results show that the inclusion of PCM into the building envelope is a promising strategy to increase the energy performance in buildings during both heating and cooling seasons in Seoul, Tokyo and Hong Kong under future climate conditions. The energy savings achieved by using PCMs in those regions are electricity savings of 4.48–8.21%, 3.81–9.69%, and 1.94–5.15%, and gas savings of 1.65–16.59%, 7.60–61.76%, and 62.07–93.33% in Seoul, Tokyo and Hong Kong, respectively, for the years 2017, 2020, 2050 and 2080. In addition, BioPCM and RUBITHERMPCM are the most efficient for improving thermal performance and saving energy in buildings in the tested regions and years.

  19. Power Stabilization Strategy of Random Access Loads in Electric Vehicles Wireless Charging System at Traffic Lights

    Directory of Open Access Journals (Sweden)

    Linlin Tan

    2016-10-01

    Full Text Available An opportunity wireless charging system for electric vehicles when they stop and wait at traffic lights is proposed in this paper. In order to solve the serious power fluctuation caused by random access loads, this study presents a power stabilization strategy based on counting the number of electric vehicles in a designated area, including counting method, power source voltage adjustment strategy and choice of counting points. Firstly, the circuit model of a wireless power system with multi-loads is built and the equation of each load is obtained. Secondly, after the counting method of electric vehicles is stated, the voltage adjustment strategy, based on the number of electric vehicles when the system is at a steady state, is set out. Then, the counting points are chosen according to power curves when the voltage adjustment strategy is adopted. Finally, an experimental prototype is implemented to verify the power stabilization strategy. The experimental results show that, with the application of this strategy, the charging power is stabilized with the fluctuation of no more than 5% when loads access randomly.

  20. Switching from originator brand medicines to generic equivalents in selected developing countries: how much could be saved?

    Science.gov (United States)

    Cameron, Alexandra; Mantel-Teeuwisse, Aukje K; Leufkens, Hubert G M; Laing, Richard Ogilvie

    2012-01-01

    In low- and middle-income countries, patients and reimbursement agencies that purchase medicines in the private sector pay more for originator brands when generic equivalents exist. We estimated the savings that could be obtained from a hypothetical switch in medicine consumption from originator brands to lowest-priced generic equivalents for a selection of medicines in 17 countries. In this cost minimization analysis, the prices of originator brands and their lowest-priced generic equivalents were obtained from facility-based surveys conducted by using a standard methodology. Fourteen medicines most commonly included in the surveys, plus three statins, were included in the analysis. For each medicine, the volume of private sector consumption of the originator brand product was obtained from IMS Health, Inc. Volumes were applied to the median unit prices for both originator brands and their lowest-priced generics to estimate cost savings. Prices were adjusted to 2008 by using consumer price index data and were adjusted for purchasing power parity. For the medicines studied, an average of 9% to 89% could be saved by an individual country from a switch in private sector purchases from originator brands to lowest-priced generics. In public hospitals in China, US $ 370 million could be saved from switching only four medicines, saving an average of 65%. Across individual medicines, average potential savings ranged from 11% for beclometasone inhaler to 73% for ceftriaxone injection. Substantial savings could be achieved by switching private sector purchases from originator brand medicines to lowest-priced generic equivalents. Strategies to promote generic uptake, such as generic substitution by pharmacists and increasing confidence in generics by professionals and the public, should be included in national medicines policies. Copyright © 2012 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  1. Example for electrical energy savings with the pump adjustable electric drive

    International Nuclear Information System (INIS)

    Mirchevski, Slobodan; Andonov, Zdravko; Saracevic, Fahrudin; Micevski, Darko; Buchkoski, Aleksandar

    2004-01-01

    Most used method of flow regulation is by throttling the pipeline. Development of power electronic gives opportunity for induction motor pump drives speed control. The common ways of pump flow control are throttling, reducing the working circle, usage of fore circle shovels rotating, by pass and pump speed control Only pump speed control is the most suitable for the energy possibilities. Intensive development of power electronic gives. opportunity to create devices - power converters, which can change the speed of induction motor. For that improvement the energy savings the measurements of power consumption with throttling and speed control have been made. Also, the MATLAB-SIMULINK model of the measured system has been made. The economic effects of saving energy using adjustable speed drives are analyzed for the measured values. The analysis shows that the money payback period of speed controller investment is short compared with the drive lifetime (20 years). (Author)

  2. Application of a High-Power Reversible Converter in a Hybrid Traction Power Supply System

    Directory of Open Access Journals (Sweden)

    Gang Zhang

    2017-03-01

    Full Text Available A high-power reversible converter can achieve a variety of functions, such as recovering regenerative braking energy, expanding traction power capacity, and improving an alternating current (AC grid power factor. A new hybrid traction power supply scheme, which consists of a high-power reversible converter and two 12-pulse diode rectifiers, is proposed. A droop control method based on load current feed-forward is adopted to realize the load distribution between the reversible converter and the existing 12-pulse diode rectifiers. The direct current (DC short-circuit characteristics of the reversible converter is studied, then the relationship between the peak fault current and the circuit parameters is obtained from theoretical calculations and validated by computer simulation. The first two sets of 2 MW reversible converters have been successfully applied in Beijing Metro Line 10, the proposed hybrid application scheme and coordinated control strategy are verified, and 11.15% of average energy-savings is reached.

  3. Assessment of women savings and credit cooperative services in ...

    African Journals Online (AJOL)

    Assessment of women savings and credit cooperative services in Zuway Dugda District, south east Ethiopia. ... Journal of Business and Administrative Studies ... and to the improvement of decision making power of members at family level.

  4. New control strategy of stand-alone brushless doubly-fed induction generator for supplying unbalanced loads in ship shaft power generation system

    DEFF Research Database (Denmark)

    Liu, Yi; Xu, Wei; Xiong, Fei

    2017-01-01

    The ship shaft power generation system based on a stand-alone brushless doubly-fed induction generator (BDFIG) have demonstrated excellent saving-energy performance. This paper presents a new control scheme of the stand-alone BDFIG for supplying unbalanced loads in the ship shaft power generation...

  5. Energy-saving approaches to solid state street lighting

    Science.gov (United States)

    Vitta, Pranciškus; Stanikūnas, Rytis; Tuzikas, Arūnas; Reklaitis, Ignas; Stonkus, Andrius; Petrulis, Andrius; Vaitkevičius, Henrikas; Žukauskas, Artūras

    2011-10-01

    We consider the energy-saving potential of solid-state street lighting due to improved visual performance, weather sensitive luminance control and tracking of pedestrians and vehicles. A psychophysical experiment on the measurement of reaction time with a decision making task was performed under mesopic levels of illumination provided by a highpressure sodium (HPS) lamp and different solid-state light sources, such as daylight and warm-white phosphor converted light-emitting diodes (LEDs) and red-green-blue LED clusters. The results of the experiment imply that photopic luminances of road surface provided by solid-state light sources with an optimized spectral power distribution might be up to twice as low as those provided by the HPS lamp. Dynamical correction of road luminance against road surface conditions typical of Lithuanian climate was estimated to save about 20% of energy in comparison with constant-level illumination. The estimated energy savings due to the tracking of pedestrians and vehicles amount at least 25% with the cumulative effect of intelligent control of at least 40%. A solid-state street lighting system with intelligent control was demonstrated using a 300 m long test ground consisting of 10 solid-state street luminaires, a meteorological station and microwave motion sensor network operated via power line communication.

  6. A DFuzzy-DAHP Decision-Making Model for Evaluating Energy-Saving Design Strategies for Residential Buildings

    Directory of Open Access Journals (Sweden)

    Yu-Lung Chen

    2012-11-01

    Full Text Available The construction industry is a high-pollution and high-energy-consumption industry. Energy-saving designs for residential buildings not only reduce the energy consumed during construction, but also reduce long-term energy consumption in completed residential buildings. Because building design affects investment costs, designs are often influenced by investors’ decisions. A set of appropriate decision-support tools for residential buildings are required to examine how building design influences corporations externally and internally. From the perspective of energy savings and environmental protection, we combined three methods to develop a unique model for evaluating the energy-saving design of residential buildings. Among these methods, the Delphi group decision-making method provides a co-design feature, the analytical hierarchy process (AHP includes multi-criteria decision-making techniques, and fuzzy logic theory can simplify complex internal and external factors into easy-to-understand numbers or ratios that facilitate decisions. The results of this study show that incorporating solar building materials, double-skin facades, and green roof designs can effectively provide high energy-saving building designs.

  7. Save production: a bottom-up energy model for Dutch industry and agriculture

    International Nuclear Information System (INIS)

    Daniels, B.W.; Dril, A.W.N. van

    2007-01-01

    A new version of the model Save production simulates the development of energy use in the Dutch industry and agriculture, including combined heat and power generation. The model disaggregates national energy consumption into fuel types, industrial sectors, energy functions and energy technologies. Simulation is based on microeconomic investment behavior. Examples of model application show results on the penetration of combined heat and power in relation to policy instruments such as CO 2 prices, electricity price support and investment subsidies. Policies that discriminate on CO 2 emissions result in a slightly more efficient heat and power generation. Tailored to the Dutch situation, Save production is well equipped to generate outlooks for the Dutch industrial and agricultural energy use, and for analyzing the role of policies in detail. Its main strength lies in the middle term simulation of decision-making on energy saving technologies and analysis of policy effects. Specific precautions are required when the model is used for analysis on the longer-term, for simulating extreme policies or for the analysis of extremely fluctuating energy prices. (author)

  8. Security strategy of powered-off SRAM for resisting physical attack to data remanence

    International Nuclear Information System (INIS)

    Yu Kai; Zou Xuecheng; Yu Guoyi; Wang Weixu

    2009-01-01

    This paper presents a security strategy for resisting a physical attack utilizing data remanence in powered-off static random access memory (SRAM). Based on the mechanism of physical attack to data remanence, the strategy intends to erase data remanence in memory cells once the power supply is removed, which disturbs attackers trying to steal the right information. Novel on-chip secure circuits including secure power supply and erase transistor are integrated into conventional SRAM to realize erase operation. Implemented in 0.25 μm Huahong-NEC CMOS technology, an SRAM exploiting the proposed security strategy shows the erase operation is accomplished within 0.2 μs and data remanence is successfully eliminated. Compared with conventional SRAM, the retentive time of data remanence is reduced by 82% while the operation power consumption only increases by 7%.

  9. Frequency Control Strategy for Black Starts via PMSG-Based Wind Power Generation

    Directory of Open Access Journals (Sweden)

    Yi Tang

    2017-03-01

    Full Text Available The use of wind power generation (WPG as a source for black starts will significantly enhance the resiliency of power systems and shorten their recovery time from blackouts. Given that frequency stability is the most serious issue during the initial recovery period, virtual inertia control can enable wind turbines to provide frequency support to an external system. In this study, a general procedure of WPG participating in black starts is presented, and the key issues are discussed. The adaptability of existing virtual inertia control strategies is analyzed, and improvement work is performed. A new coordinated frequency control strategy is proposed based on the presented improvement work. A local power network with a permanent-magnet synchronous generator (PMSG-based wind farm is modeled and used to verify the effectiveness of the strategy.

  10. THE PUZZLE OF SIMULTANEOUS SAVINGS AND DEBTS

    Directory of Open Access Journals (Sweden)

    RODICA IANOLE

    2012-05-01

    Full Text Available „Neither a borrower nor a lender be” recommends Shakespeare in Hamlet. The advice seems particularly interesting in nowadays society where a person can be easily found in both approximate situations, in the same time. It goes without saying that saving and borrowing do not describe mutually exclusive strategies of financial management and thus many people retain savings or carry on saving at the same time as having debts. We add to this fact a more pragmatically wisdom, the one of the economist Robert Solow -“We (economists think of wealth as fungible; we think a dollar is a dollar. Why don't they (the others do so?” (Solow, 1987 – and we naturally ask ourselves if the mechanism of having simultaneous savings and debts is a rational one, according to traditional economics.Making appeal to the emerging body of behavioral economics literature we reach to the mental accounting theory to see if it can explain savings inclination versus debt inclination. The main research question we want to explore is the following: if mental accounting prevents people from spending money from one „mental account” on goods belonging to another one, will people – after using all their money from a given account – be willing to go into debt to buy goods belonging to this account in a situation when they still have money in other accounts?

  11. The sales strategies of electric power and natural gas in France

    International Nuclear Information System (INIS)

    Heddebaut, D.

    2005-01-01

    This study presents a whole panorama of the commercial strategies developed by the electric power and natural gas suppliers. Based on interviews, this study provides data keys and development strategies of 13 operators of the energy french market. (A.L.B.)

  12. Best control strategy for unified power quality conditioner (UPQC) based on simulation

    Energy Technology Data Exchange (ETDEWEB)

    Shayanfar, H.A. [Iran Univ. of Science and Technology, Tehran (Iran, Islamic Republic of). Dept. of Electrical Engineering; Tabatabaei, N.M. [Azarbaijan Univ. of Tarbiat Moallem, Tabriz (Iran, Islamic Republic of). Dept. of Electrical Engineering; Mokhtarpour, A. [Islamic Azad Univ., Tabriz (Iran, Islamic Republic of). Dept. of Electrical Engineering

    2007-07-01

    Electronic devices used in both industry and residences need high-quality energy to work properly. Unified Power Quality Conditioners (UPQC) solve any power quality problems faced by these devices. Three new control strategies for UPQCs were presented and their operation was investigated and compared using the MATLAB Simulink simulation software package. A UPQC consists of a Shunt-Active Filter and a Series Active Filter with a common direct current link to compensate for any source currents and delivered voltage to the load. As such, it isolates the utility from current quality problems associated with load. It also isolates the load from the voltage quality problems of the utility. In the first control strategy, the Parallel Active Filter (PAF) and Series Active Filter (SAF) are based on the Fourier transform theory. In the second control strategy, the Parallel Active Filter is based on the power quality theory and the Series Active Filter is based on the Fourier transform theory. In the third control strategy, the Parallel Active Filter is based on Fourier transform theory and the Series Active Filter is based on positive sequence detection. Operating the PAF using these methods compensates for reactive power and current harmonics, while operating the SAF compensates for imbalances, voltage harmonics and positive and zero sequences of utility voltages. MATLAB simulation software was used to explain the compensation resolution and speed of the 3 new control strategies. According to simulation test results, it was concluded that the best compensation speed and resolution can be obtained using the third control strategy. 7 refs., 2 tabs., 24 figs.

  13. LHC Inner Triplet Powering Strategy

    CERN Document Server

    Bordry, Frederick

    2001-01-01

    In order to achieve a luminosity in excess of 10**34 cm**-2s**-1 at the Large Hadron Collider (LHC), special high gradient quadrupoles are required for the final focusing triplets. These low-b triplets, located in the four experimental insertions (ATLAS, CMS, ALICE, LHC-B), consist of four wide-aperture superconducting magnets: two outer quadrupoles, Q1 and Q3, with a maximum current of 7 kA and a central one divided into two identical magnets, Q2a and Q2b, with a maximum current of 11.5 kA. To optimise the powering of these mixed quadrupoles, it was decided to use two nested high-current power converters : [8kA, 8V] and [6kA, 8V]. This paper presents the consequence of the interaction between the two galvanically coupled circuits. A control strategy, using two independent, standard, LHC digital controllers, to decouple the two systems is proposed and described. The converter protection during the discharge of the magnet energy due to quenches or interlocks of the magnets are discussed. Simulation and experim...

  14. Short-term strategies for Dutch wind power producers to reduce imbalance costs

    International Nuclear Information System (INIS)

    Chaves-Ávila, José Pablo; Hakvoort, Rudi A.; Ramos, Andrés

    2013-01-01

    The paper assesses bidding strategies for a wind power producer in the Netherlands. To this end, a three-stage stochastic optimization framework is used, maximizing wind power producer's profit using the day-ahead and cross-border intraday market, taking into account available interconnection capacity. Results show that the wind power producer can increase its profits by trading on the intraday market and – under certain imbalance prices – by intentionally creating imbalances. It has been considered uncertainties about prices, power forecast and interconnection capacity at the day-ahead and intraday timeframes. - Highlights: ► A cross-border bidding strategy model for wind power producers has been developed. ► The model was applied to a real case study of a Dutch offshore wind power producer. ► Under certain imbalance prices, it is not profitable to deliver all possible power. ► Intraday markets give the possibility to reduce imbalance costs. ► Integration of intraday markets will increase liquidity.

  15. Management of fluctuations in wind power and CHP comparing two possible Danish strategies

    International Nuclear Information System (INIS)

    Lund, H.; Clark, W.W.

    2002-01-01

    Both CHP (combined heat and power production) and wind power are important elements of Danish energy policy. Today, approximately 50% of both the Danish electricity and heat demand are produced in CHP and more than 15% of the electricity demand is produced by wind turbines. Both technologies are essential for the implementation of Danish climate change response objectives, and both technologies are intended for further expansion in the coming decade. Meanwhile, the integration of CHP and wind power is subject to fluctuations in electricity production. Wind turbines depend on the wind, and CHP depends on the heat demand. This article discusses and analyses two different national strategies for solving this problem. One strategy, which is the current official government policy known as the export strategy, proposes to take advantage of the Nordic and European markets for selling and buying electricity. In this case, surplus electricity from wind power and CHP simply will be sold to neighbouring countries. Another strategy, the self-supply strategy, runs the CHP units to meet both demand and the fluctuations in the wind scheduling. In this case, investments in heat storages are necessary and heat pumps have to be added to the CHP units. Based on official Danish energy policy and energy plans, this article quantifies the problem for the year 2015 in terms of the amount of surplus electricity, and investments in heat pumps, etc. needed to solve the problem are calculated. Based on these results between the two different strategies, the conclusion is that the self-supply strategy is recommended over the official export strategy. (author)

  16. A Fuzzy-Logic Power Management Strategy Based on Markov Random Prediction for Hybrid Energy Storage Systems

    Directory of Open Access Journals (Sweden)

    Yanzi Wang

    2016-01-01

    Full Text Available Over the last few years; issues regarding the use of hybrid energy storage systems (HESSs in hybrid electric vehicles have been highlighted by the industry and in academic fields. This paper proposes a fuzzy-logic power management strategy based on Markov random prediction for an active parallel battery-UC HESS. The proposed power management strategy; the inputs for which are the vehicle speed; the current electric power demand and the predicted electric power demand; is used to distribute the electrical power between the battery bank and the UC bank. In this way; the battery bank power is limited to a certain range; and the peak and average charge/discharge power of the battery bank and overall loss incurred by the whole HESS are also reduced. Simulations and scaled-down experimental platforms are constructed to verify the proposed power management strategy. The simulations and experimental results demonstrate the advantages; feasibility and effectiveness of the fuzzy-logic power management strategy based on Markov random prediction.

  17. The structure and control method of hybrid power source for electric vehicle

    International Nuclear Information System (INIS)

    Li, Maobing; Xu, Hui; Li, Weimin; Liu, Yin; Li, Fade; Hu, Yue; Liu, Li

    2016-01-01

    In this paper, an electric vehicle powertrain configuration is presented, which the lithium-ion battery integrated with ultracapacitors is developed as the hybrid power system to improve the transient performance of an electric vehicle, and to decrease the damage to the battery pack. In the proposed system, a bidirectional direct current/direct current converter is used to couple the ultracapacitors bank to the main battery pack. The energy management strategy based on fuzzy logic for hybrid power system has been proposed to promote the performance of energy flow in the electric vehicle. The experiment results in urban driving cycles show remarkable advantages of the proposed hybrid system configuration and energy management strategy. About 30% of the battery capacity energy is saved while using the hybrid power source. Besides, the voltage and current curves of battery become smoother than that with the single power. - Highlights: • A hybrid power source electric vehicle powertrain configuration is presented. • The energy management strategy based on fuzzy logic is proposed. • The experiment results show remarkable advantages of the configuration and method.

  18. Promoting energy-saving and environmentally friendly generation dispatching model in China: Phase development and case studies

    DEFF Research Database (Denmark)

    Ding, Yi; Yang, Hongliang

    2013-01-01

    Energy saving and environmental protection are important conditions for the sustainable development of Chinese economy. However current widely used generation scheduling model based on predefined production quota and tariff results in heavy energy consumption and severe environment pollution. From...... 2007, as concerns over energy shortage and environmental pollution, the Chinese authorities introduced the implementation of energy-saving generation dispatching model, which is an important approach to facilitating energy-saving and reduction of pollutant emission. The objective of implementing energy......-saving generation dispatching model is to prioritize the use of renewable energy resources and new power plants with high efficiency without compromising power system security and reliability. This paper analyzes the necessity and feasibility of implementing energy-efficient and environmentally friendly generation...

  19. Control strategy research of two stage topology for pulsed power supply

    International Nuclear Information System (INIS)

    Shi Chunfeng; Wang Rongkun; Huang Yuzhen; Chen Youxin; Yan Hongbin; Gao Daqing

    2013-01-01

    A kind of pulsed power supply of HIRFL-CSR was introduced, the ripple and the current error of the topological structure of the power in the operation process were analyzed, and two stage topology of pulsed power supply was given. The control strategy was simulated and the experiment was done in digital power platform. The results show that the main circuit structure and control method are feasible. (authors)

  20. Demand management through centralized control system using power line communication for existing buildings

    International Nuclear Information System (INIS)

    Al-Mulla, A.; ElSherbini, A.

    2014-01-01

    Highlights: • A pilot system was developed for demand management of equipment in buildings. • The networking was based on LonWorks platform and power line communication. • Demand strategies led to load reductions up to 74% and energy savings up to 25%. • The peak load reduction is expected to reach 3.44 GW by the year 2030. - Abstract: Managing peak demand efficiently is vital for maintaining uninterrupted supply of electrical power by utility providers. In this work, a pilot system was developed for managing and controlling the demand of major power consuming equipment in buildings from a central server, while relying mostly on existing infrastructure and maintaining consumer comfort. The system was successfully demonstrated on a selected group of buildings using the LonWorks networking platform. At the building level, the system utilized power line and twisted pair communication to control the thermostats of air-conditioning (A/C) units. The higher level communication was executed through extensible markup language (XML) and simple object access protocol (SOAP). The system provided control capabilities based on A/C unit priority, thermostat temperature, building type and geographic location. The development and execution of demand management strategies for selected buildings led to peak load reductions up to 74%, in addition to energy savings up to 25%. Implementing such a system at a national level in Kuwait is estimated to reduce peak demand by 3.44 GW, amounting to capital savings of $4.13 billion. The use of existing infrastructure reduced the cost and installation time of the system. Based on the successful testing of this pilot system, a larger-scale system is being developed

  1. Maximum wind energy extraction strategies using power electronic converters

    Science.gov (United States)

    Wang, Quincy Qing

    2003-10-01

    This thesis focuses on maximum wind energy extraction strategies for achieving the highest energy output of variable speed wind turbine power generation systems. Power electronic converters and controls provide the basic platform to accomplish the research of this thesis in both hardware and software aspects. In order to send wind energy to a utility grid, a variable speed wind turbine requires a power electronic converter to convert a variable voltage variable frequency source into a fixed voltage fixed frequency supply. Generic single-phase and three-phase converter topologies, converter control methods for wind power generation, as well as the developed direct drive generator, are introduced in the thesis for establishing variable-speed wind energy conversion systems. Variable speed wind power generation system modeling and simulation are essential methods both for understanding the system behavior and for developing advanced system control strategies. Wind generation system components, including wind turbine, 1-phase IGBT inverter, 3-phase IGBT inverter, synchronous generator, and rectifier, are modeled in this thesis using MATLAB/SIMULINK. The simulation results have been verified by a commercial simulation software package, PSIM, and confirmed by field test results. Since the dynamic time constants for these individual models are much different, a creative approach has also been developed in this thesis to combine these models for entire wind power generation system simulation. An advanced maximum wind energy extraction strategy relies not only on proper system hardware design, but also on sophisticated software control algorithms. Based on literature review and computer simulation on wind turbine control algorithms, an intelligent maximum wind energy extraction control algorithm is proposed in this thesis. This algorithm has a unique on-line adaptation and optimization capability, which is able to achieve maximum wind energy conversion efficiency through

  2. Max Tech Appliance Design: Potential for Maximizing U.S. Energy Savings through Standards

    Energy Technology Data Exchange (ETDEWEB)

    Garbesi, Karina; Desroches, Louis-Benoit; Bolduc, Christopher; Burch, Gabriel; Hosseinzadeh, Griffin; Saltiel, Seth

    2011-05-06

    This study surveyed the technical potential for efficiency improvements in 150 categories of appliances and equipment representing 33 quads of primary energy use across the US economy in 2010 and (1) documented efficient product designs, (2) identified the most promising cross-cutting strategies, and (3) ranked national energy savings potential by end use. Savings were estimated using a method modeled after US Department of Energy priority-setting reports - simplified versions of the full technical and economic analyses performed for rulemakings. This study demonstrates that large savings are possible by replacing products at the end-of-life with ultra-efficient models that use existing technology. Replacing the 50 top energy-saving end-uses (constituting 30 quads of primary energy consumption in 2010) with today's best-on-market equivalents would save {approx}200 quads of US primary energy over 30 years (25% of consumption anticipated there from). For the 29 products for maximum feasible savings potential could be estimated, the savings were twice as high. These results demonstrate that pushing ultra-efficient products to market could significantly escalate carbon emission reductions and is a viable strategy for sustaining large emissions reductions through standards. The results of this analysis were used by DOE for new coverage prioritization, to identify key opportunities for product prototyping and market development, and will leverage future standards rulemakings by identifying the full scope of maximum feasible technology options. High leverage products include advances lighting systems, HVAC, and televisions. High leverage technologies include electronic lighting, heat pumps, variable speed motors, and a host of controls-related technologies.

  3. Exploring Northwest China's agricultural water-saving strategy: analysis of water use efficiency based on an SE-DEA model conducted in Xi'an, Shaanxi Province.

    Science.gov (United States)

    Mu, L; Fang, L; Wang, H; Chen, L; Yang, Y; Qu, X J; Wang, C Y; Yuan, Y; Wang, S B; Wang, Y N

    Worldwide, water scarcity threatens delivery of water to urban centers. Increasing water use efficiency (WUE) is often recommended to reduce water demand, especially in water-scarce areas. In this paper, agricultural water use efficiency (AWUE) is examined using the super-efficient data envelopment analysis (DEA) approach in Xi'an in Northwest China at a temporal and spatial level. The grey systems analysis technique was then adopted to identify the factors that influenced the efficiency differentials under the shortage of water resources. From the perspective of temporal scales, the AWUE increased year by year during 2004-2012, and the highest (2.05) was obtained in 2009. Additionally, the AWUE was the best in the urban area at the spatial scale. Moreover, the key influencing factors of the AWUE are the financial situations and agricultural water-saving technology. Finally, we identified several knowledge gaps and proposed water-saving strategies for increasing AWUE and reducing its water demand by: (1) improving irrigation practices (timing and amounts) based on compatible water-saving techniques; (2) maximizing regional WUE by managing water resources and allocation at regional scales as well as enhancing coordination among Chinese water governance institutes.

  4. Strategies for the Funding Crisis: Helping to Save Your School Library

    Science.gov (United States)

    Geier, Denise B.

    2011-01-01

    In January 2007, the author wrote an article titled "Prevent a Disaster in Your Library: Advertise." In 2011, with the ongoing economic crisis that has caused so many school budget cuts, it is clear that advertising is no longer enough to save school librarians' positions. Librarians need to become even more aggressive as they market their…

  5. QoE-based transmission strategies for multi-user wireless information and power transfer

    Directory of Open Access Journals (Sweden)

    Taehun Jung

    2015-12-01

    Full Text Available One solution to the problem of supplying energy to wireless networks is wireless power transfer. One such technology–electromagnetic radiation enabled wireless power transfer–will change traditional wireless networks. In this paper, we investigate a transmission strategy for multi-user wireless information and power transfer. We consider a multi-user multiple-input multiple-output (MIMO channel that includes one base station (BS and two user terminals (UT consisting of one energy harvesting (EH receiver and one information decoding (ID receiver. Our system provides transmission strategies that can be executed and implemented in practical scenarios. The paper then analyzes the rate–energy (R–E pair of our strategies and compares them to those of the theoretical optimal strategy. We furthermore propose a QoE-based mode selection algorithm by mapping the R–E pair to the utility functions.

  6. Bomber Deployments: A New Power Projection Strategy

    Science.gov (United States)

    2016-08-21

    AIR COMMAND AND STAFF COLLEGE DISTANCE LEARNING AIR UNIVERSITY BOMBER DEPLOYMENTS: A NEW POWER PROJECTION STRATEGY by...operating base (FOB), main operating base ( MOB ) and intermediate staging base (ISB).10 Each type of base requires certain actions to make it suitable for...closure of many main operating bases ( MOB ) overseas and the reluctance of many nations to permit permanent military bases on their soil.”15 This

  7. Review of reactive power dispatch strategies for loss minimization in a DFIG-based wind farm

    DEFF Research Database (Denmark)

    Zhang, Baohua; Hu, Weihao; Hou, Peng

    2017-01-01

    power control strategies are investigated. All of the combined strategies are formulated based on the comprehensive loss models of WFs, including the loss models of DFIGs, converters, filters, transformers, and cables of the collection system. Optimization problems are solved by a Modified Particle......This paper reviews and compares the performance of reactive power dispatch strategies for the loss minimization of Doubly Fed Induction Generator (DFIG)-based Wind Farms (WFs). Twelve possible combinations of three WF level reactive power dispatch strategies and fourWind Turbine (WT) level reactive...... Swarm Optimization (MPSO) algorithm. The effectiveness of these strategies is evaluated by simulations on a carefully designed WF under a series of cases with different wind speeds and reactive power requirements of the WF. The wind speed at each WT inside the WF is calculated using the Jensen wake...

  8. Private Sector Savings

    Directory of Open Access Journals (Sweden)

    Pitonáková Renáta

    2018-03-01

    Full Text Available The majority of household savings are in the form of bank deposits. It is therefore of interest for credit institutions to tailor their deposit policy for getting finances from non-banking entities and to provide the private sector with the loans that are necessary for investment activities and consumption. This paper deals with the determinants of the saving rate of the private sector of Slovakia. Economic, financial and demographic variables influence savings. Growth of income per capita, private disposable income, elderly dependency ratio, real interest rate and inflation have a positive impact on savings, while increases in public savings indicate a crowding out effect. The inflation rate implies precautionary savings, and dependency ratio savings for bequest. There are also implications for governing institutions deciding on the implementation of appropriate fiscal and monetary operations.

  9. On the Dual-Decomposition-Based Resource and Power Allocation with Sleeping Strategy for Heterogeneous Networks

    KAUST Repository

    Alsharoa, Ahmad M.

    2015-05-01

    In this paper, the problem of radio and power resource management in long term evolution heterogeneous networks (LTE HetNets) is investigated. The goal is to minimize the total power consumption of the network while satisfying the user quality of service determined by each target data rate. We study the model where one macrocell base station is placed in the cell center, and multiple small cell base stations and femtocell access points are distributed around it. The dual decomposition technique is adopted to jointly optimize the power and carrier allocation in the downlink direction in addition to the selection of turned off small cell base stations. Our numerical results investigate the performance of the proposed scheme versus different system parameters and show an important saving in terms of total power consumption. © 2015 IEEE.

  10. Does Daylight Saving Save Energy? A Meta-Analysis

    OpenAIRE

    Havránek, Tomáš; Herman, Dominik; Irsova, Zuzana

    2016-01-01

    The original rationale for adopting daylight saving time (DST) was energy savings. Modern research studies, however, question the magnitude and even direction of the effect of DST on energy consumption. Representing the first meta-analysis in this literature, we collect 162 estimates from 44 studies and find that the mean reported estimate indicates modest energy savings: 0.34% during the days when DST applies. The literature is not affected by publication bias, but the results vary systemati...

  11. Power flow control strategy in distribution network for dc type distributed energy resource at load bus

    International Nuclear Information System (INIS)

    Hanif, A.; Choudhry, M.A.

    2013-01-01

    This research work presents a feed forward power flow control strategy in the secondary distribution network working in parallel with a DC type distributed energy resource (DER) unit with SPWM-IGBT Voltage Source Converter (VSC). The developed control strategy enables the VSC to be used as power flow controller at the load bus in the presence of utility supply. Due to the investigated control strategy, power flow control from distributed energy resource (DER) to common load bus is such that power flows to the load without facing any power quality problem. The technique has an added advantage of controlling power flow without having a dedicated power flow controller. The SPWM-IGBT VSC is serving the purpose of dc-ac converter as well as power flow controller. Simulations for a test system using proposed power flow control strategy are carried out using SimPower Systems toolbox of MATLAB at the rate and Simulink at the rate. The results show that a reliable, effective and efficient operation of DC type DER unit in coordination with main utility network can be achieved. (author)

  12. An improved power control strategy for hybrid AC-DC microgrids

    DEFF Research Database (Denmark)

    Baharizadeh, Mehdi; Karshenas, Hamid Reza; Guerrero, Josep M.

    2018-01-01

    This paper presents a new droop-based control strategy for hybrid microgrids (HMG) with improved power sharing. When ac microgrids (AC-MG) and dc microgrids (DC-MG) are present in a distribution grid, there is an opportunity to interconnect them via an interlinking converter (IC) and form a HMG......, the possibility of participation of IC in AC-MG reactive power adds some complexity to a HMG control system. In this paper, a new decentralized control strategy is presented for a HMG which relies on regulating the voltage magnitude of a common bus in each microgrid. In this regard, new droop characteristics...... for sources across both microgrids as well as IC are proposed. The proposed droop characteristics result in better active/reactive power sharing across both microgrids and at the same time results in better voltage regulation. The derivation of new droop characteristics is thoroughly discussed in this paper...

  13. Pool Strategy of a Price-Maker Wind Power Producer

    DEFF Research Database (Denmark)

    Zugno, Marco; Morales González, Juan Miguel; Pinson, Pierre

    2013-01-01

    We consider the problem of a wind power producer trading energy in short-term electricity markets. The producer is a price-taker in the day-ahead market, but a price-maker in the balancing market, and aims at optimizing its expected revenues from these market floors. The problem is formulated...... or median forecast of wind power distribution. Finally, sensitivity analyses are carried out to assess the impact on the offering strategy of the producer's penetration in the market, of the correlation between wind power production and residual system deviation, and of the shape of the forecast...

  14. Fault analysis and strategy of high pulsed power supply for high power laser

    International Nuclear Information System (INIS)

    Liu Kefu; Qin Shihong; Li Jin; Pan Yuan; Yao Zonggan; Zheng Wanguo; Guo Liangfu; Zhou Peizhang; Li Yizheng; Chen Dehuai

    2001-01-01

    according to the requirements of driving flash-lamp, a high pulsed power supply (PPS) based on capacitors as energy storage elements is designed. The author analyzes in detail the faults of high pulsed power supply for high power laser. Such as capacitor internal short-circuit, main bus breakdown to ground, flashlamp sudden short or break. The fault current and voltage waveforms were given by circuit simulations. Based on the analysis and computation, the protection strategy with the fast fuse and ZnO was put forward, which can reduce the damage of PPS to the lower extent and provide the personnel safe and collateral property from the all threats. The preliminary experiments demonstrated that the design of the PPS can satisfy the project requirements

  15. Joule-Thief Circuit Performance for Electricity Energy Saving of Emergency Lamps

    Science.gov (United States)

    Nuryanto Budisusila, Eka; Arifin, Bustanul

    2017-04-01

    The alternative energy such as battery as power source is required as energy source failures. The other need is outdoor lighting. The electrical power source is expected to be a power saving, optimum and has long life operating. The Joule-Thief circuit is one of solution method for energy saving by using raised electromagnetic force on cored coil when there is back-current. This circuit has a transistor operated as a switch to cut voltage and current flowing along the coils. The present of current causing magnetic induction and generates energy. Experimental prototype was designed by using battery 1.5V to activate Light Emitting Diode or LED as load. The LED was connected in parallel or serial circuit configuration. The result show that the joule-thief circuit able to supply LED circuits up to 40 LEDs.

  16. Effect of energy saving lights on power supply

    NARCIS (Netherlands)

    Timens, R.B.; Buesink, Frederik Johannes Karel; Leferink, Frank Bernardus Johannes

    2012-01-01

    Weak power supply networks are very sensitive to non-linear low power loads. Electronics in low power loads are non-linear, very basic, and consisting of a rectifier bridge and bulk capacitor, consuming current only in the peak of the supplied voltage. Due to the relative high power supply network

  17. Evaluation of the performance of combined cooling, heating, and power systems with dual power generation units

    International Nuclear Information System (INIS)

    Knizley, Alta A.; Mago, Pedro J.; Smith, Amanda D.

    2014-01-01

    The benefits of using a combined cooling, heating, and power system with dual power generation units (D-CCHP) is examined in nine different U.S. locations. One power generation unit (PGU) is operated at base load while the other is operated following the electric load. The waste heat from both PGUs is used for heating and for cooling via an absorption chiller. The D-CCHP configuration is studied for a restaurant benchmark building, and its performance is quantified in terms of operational cost, primary energy consumption (PEC), and carbon dioxide emissions (CDE). Cost spark spread, PEC spark spread, and CDE spark spread are examined as performance indicators for the D-CCHP system. D-CCHP system performance correlates well with spark spreads, with higher spark spreads signifying greater savings through implementation of a D-CCHP system. A new parameter, thermal difference, is introduced to investigate the relative performance of a D-CCHP system compared to a dual PGU combined heat and power system (D-CHP). Thermal difference, together with spark spread, can explain the variation in savings of a D-CCHP system over a D-CHP system for each location. The effect of carbon credits on operational cost savings with respect to the reference case is shown for selected locations. - Highlights: • We investigate benefits from using combined cooling, heating, and power systems. • A dual power generation unit configuration is considered for CCHP and CHP. • Spark spreads for cost, energy, and emissions correlate with potential savings. • Thermal difference parameter helps to explain variations in potential savings. • Carbon credits may increase cost savings where emissions savings are possible

  18. Chapter 23: Combined Heat and Power Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Simons, George [Itron, Davis, CA (United States); Barsun, Stephan [Itron, Davis, CA (United States)

    2017-11-06

    The main focus of most evaluations is to determine the energy-savings impacts of the installed measure. This protocol defines a combined heat and power (CHP) measure as a system that sequentially generates both electrical energy and useful thermal energy from one fuel source at a host customer's facility or residence. This protocol is aimed primarily at regulators and administrators of ratepayer-funded CHP programs; however, project developers may find the protocol useful to understand how CHP projects are evaluated.

  19. Coordinated Control Strategies of VSC-HVDC-Based Wind Power Systems for Low Voltage Ride Through

    Directory of Open Access Journals (Sweden)

    Xinyin Zhang

    2015-07-01

    Full Text Available The Voltage Source Converter-HVDC (VSC-HVDC system applied to wind power generation can solve large scale wind farm grid-connection and long distance transmission problems. However, the low voltage ride through (LVRT of the VSC-HVDC connected wind farm is a key technology issue that must be solved, and it is currently lacking an economic and effective solution. In this paper, a LVRT coordinated control strategy is proposed for the VSC-HVDC-based wind power system. In this strategy, the operation and control of VSC-HVDC and wind farm during the grid fault period is improved. The VSC-HVDC system not only provides reactive power support to the grid, but also effectively maintains the power balance and DC voltage stability by reducing wind-farm power output, without increasing the equipment investment. Correspondingly, to eliminate the influence on permanent magnet synchronous generator (PMSG-based wind turbine (WT systems, a hierarchical control strategy is designed. The speed and validity of the proposed LVRT coordinated control strategy and hierarchical control strategy were verified by MATLAB/Simulink simulations.

  20. Mobile recommender application for promoting electricity saving among Iraqis

    Science.gov (United States)

    Sabri, Manhal Isam; Hussain, Azham

    2017-10-01

    Mobile utilization has rapidly expanded due to its feasibility in executing different applications that can be used in solving everyday problems. Common issues in daily life include electricity saving. In Iraq, the Ministry of Power seriously faces such issue. This is because most households have lack access to information regarding to sufficient power consumption, as well as applications that educate about such saving. Therefore, this study aims at developing a mobile application for Iraqi to help them understand the basis for reducing electricity consumption based on the meter data supplied by the users for square meter along with the active devices and period of usage. The proposed mobile application was evaluated by 50 households from the perspective of ease of use, usefulness, ease of learning, and satisfaction. The obtained result showed that majority of the participants found the application to be ease to use, useful, easy to learn, and were satisfied with its functionalities. The study findings provide some insights about the importance of using mobile application for promoting households in Iraq to manage their power consumption behavior.

  1. Resistive flux saving and current profile control during lower hybrid waves assisted current rise in TORE SUPRA

    International Nuclear Information System (INIS)

    van Houtte, D.; Hoang, G.T.; Joffrin, E.; Lecoustey, P.; Moreau, D.; Parlange, F.; Tonon, G.; Vallet, J.C.

    1992-01-01

    Resistive flux saving at densities n e = (1 - 2) x 10 19 m -3 has been studied. High flux saving efficiency (0.7 x 10 13 Wb/J/m -1 ) can be achieved for a low rf power (P LH = 0.5 MW) due to the beneficial effect of the electric field on the suprathermal electrons. However for power higher than 1 MW, the efficiency is 0.25 x 10 13 Wb/J/m -1 . This flux saving efficiency is comparable to the one obtained during the flat top phase. The application of the LH power during a low density current ramp-up tends to peak the electron temperature and current density profiles. The rf power level, the parallel wavenumber and the current ramp rate allow to control the trajectories of the plasma discharges during the current rise inside the MHD stable domain

  2. Resins characterization strategy at Kozloduy Nuclear Power Plant

    International Nuclear Information System (INIS)

    Fenoy, A.; González, R.; Molleda, P.; Sánchez, L.; Herrera, J.

    2013-01-01

    The Consortium ENSA- Gas Natural Fenosa Engineering has a contract with Kozloduy Nuclear Power Plant (KNPP) for the retrieval and conditioning of the resins. Before that, the project deals with resins characterization to verify the fulfillment the Bulgarian authorities’ requirements. The project includes all the resins generated during the operation of the BACKGROUND Resins characterization strategy at Kozloduy Nuclear Power Plant units 1, 2, 3 and 4, which were stored into six big dimensions tanks: four low tanks and two intermediate tanks. They only have a manhole above for tanks access. The methodology and the progress of the work are presented

  3. Optimum investment strategy in the power industry mathematical models

    CERN Document Server

    Bartnik, Ryszard; Hnydiuk-Stefan, Anna

    2016-01-01

    This book presents an innovative methodology for identifying optimum investment strategies in the power industry. To do so, it examines results including, among others, the impact of oxy-fuel technology on CO2 emissions prices, and the specific cost of electricity production. The technical and economic analysis presented here extend the available knowledge in the field of investment optimization in energy engineering, while also enabling investors to make decisions involving its application. Individual chapters explore the potential impacts of different factors like environmental charges on costs connected with investments in the power sector, as well as discussing the available technologies for heat and power generation. The book offers a valuable resource for researchers, market analysts, decision makers, power engineers and students alike.

  4. Some characteristics of the Hungarian power systems long term expansion strategy

    International Nuclear Information System (INIS)

    Fazekas, A.

    1995-01-01

    The formulation of the power system expansion strategy meeting the targets of the Hungarian energy policy is justified by the ageing of the existing power plants, the technology change unavoidable because of the more and more rigorous environment protection regulations, the requirement of updating and by the compliance with the expectation of safe electric power supply. These requirements (fuel supply and diversification, economic considerations, operational and environmental considerations) call for the construction of new power plant units even if the demand for electric power would not show any further increase in future. 1 tab

  5. Economical analysis of an alternative strategy for CO2 mitigation based on nuclear power

    International Nuclear Information System (INIS)

    Alonso, Gustavo; Valle, Edmundo del

    2013-01-01

    Many countries are pursuing greenhouse gas (GHG) mitigation policies resulting in the increase of use of renewable sources in the electricity sector to mitigate CO 2 emissions. Nuclear energy is a non-emitting CO 2 source that could be used as part of that policy. However, its main drawback is the high investment required for its deployment. On the other hand, wind power is the clean source preferred option to mitigate CO 2 emissions. However, due to its intermittence backup power is needed, in most of the cases it must be provided with combined cycle thermal plants using natural gas. This study performs an economical comparison of a hypothetical implementation of a nuclear strategy to meet the same CO 2 emissions reduction goal that has been obtained by the actual Spaniard strategy (2005–2010) based on wind power. The investment required in both strategies is assessed under different investment scenarios and electricity production conditions for nuclear power. Also, the cost of electricity generation is compared for both strategies. - Highlights: ► Wind power electricity cost including its backup in Spain is assessed. ► Nuclear power is proposed as an alternative to produce the same CO 2 reduction. ► Nuclear power requires less installed capacity deployment. ► Investment to produce the same CO 2 reduction is smaller using nuclear power. ► Electricity generating cost is less expensive using the nuclear option

  6. Concept for a power system controller for large space electrical power systems

    Science.gov (United States)

    Lollar, L. F.; Lanier, J. R., Jr.; Graves, J. R.

    1981-01-01

    The development of technology for a fail-operatonal power system controller (PSC) utilizing microprocessor technology for managing the distribution and power processor subsystems of a large multi-kW space electrical power system is discussed. The specific functions which must be performed by the PSC, the best microprocessor available to do the job, and the feasibility, cost savings, and applications of a PSC were determined. A limited function breadboard version of a PSC was developed to demonstrate the concept and potential cost savings.

  7. Regional strategy of energy transition. The regional strategy for energy transition in Pays-de-la-Loire for 2014-2020

    International Nuclear Information System (INIS)

    Auxiette, Jacques; Clergeau, Christophe; Bouchaud, Emmanuelle

    2014-04-01

    As the Pays-de-la-Loire region has been committed for three years in the preparation for energy transition, this publication first recalls the main objectives to be reached by 2050 regarding energy consumption, electric power consumption, oil consumption by the transport sector, and greenhouse gas emissions. It outlines the need for a national strategy on the long term for energy transition, and presents the adopted approach for the elaboration of such a regional strategy, based on several experiments. The main axes of this strategy are then presented: to better and less consume energy (through thermal renovation, sustainable mobility, energy efficiency, energy saving behaviours), to make energy transition the engine of territory development (through a support to sectors, the development of regional energy production, and optimisation of consumptions and productions), and to elaborate tools for cooperative action

  8. Power Aware Dynamic Provisioning of HPC Networks

    Energy Technology Data Exchange (ETDEWEB)

    Groves, Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Grant, Ryan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-10-01

    Future exascale systems are under increased pressure to find power savings. The network, while it consumes a considerable amount of power is often left out of the picture when discussing total system power. Even when network power is being considered, the references are frequently a decade or older and rely on models that lack validation on modern inter- connects. In this work we explore how dynamic mechanisms of an Infiniband network save power and at what granularity we can engage these features. We explore this within the context of the host controller adapter (HCA) on the node and for the fabric, i.e. switches, using three different mechanisms of dynamic link width, frequency and disabling of links for QLogic and Mellanox systems. Our results show that while there is some potential for modest power savings, real world systems need to improved responsiveness to adjustments in order to fully leverage these savings. This page intentionally left blank.

  9. Fossil energy savings potential of sugar cane bio-energy systems

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Thu Lan T. [Department of Agroecology, Aarhus University, Tjele (Denmark); The Joint Graduate School of Energy and Environment, King Mongkut' s University of Technology Thonburi, Bangkok (Thailand); Hermansen, John E. [Department of Agroecology, Aarhus University, Tjele (Denmark); Sagisaka, Masayuki [Institute of Science for Safety and Sustainability, National Institute of Advanced Industrial Science and Technology, Tsukuba (Japan)

    2009-11-15

    One important rationale for bio-energy systems is their potential to save fossil energy. Converting a conventional sugar mill into a bio-energy process plant would contribute to fossil energy savings via the extraction of renewable electricity and ethanol substituting for fossil electricity and gasoline, respectively. This paper takes a closer look at the Thai sugar industry and examines two practical approaches that will enhance fossil energy savings. The first one addresses an efficient extraction of energy in the form of electricity from the excess bagasse and cane trash. The second while proposing to convert molasses or sugar cane to ethanol stresses the use of bagasse as well as distillery spent wash to replace coal in meeting ethanol plants' energy needs. The savings potential achieved with extracting ethanol from surplus sugar versus current practice in sugar industry in Thailand amounts to 15 million barrels of oil a year. Whether the saving benefits could be fully realized, however, depends on how well the potential land use change resulting from an expansion of ethanol production is managed. The results presented serve as a useful guidance to formulate strategies that enable optimum utilization of biomass as an energy source. (author)

  10. Implementation strategy for small CHP-plants in a competitive market: the case of Lithuania

    International Nuclear Information System (INIS)

    Lund, H.; Siupsinskas, G.; Martinaitis, V.

    2005-01-01

    Within five years from now, Lithuania is going to close down Ignalina, the only nuclear-power plant in the country. Since Ignalina generates more than 75% of the Lithuanian electricity production, new generation capacities are needed. Traditional steam-turbines, fuelled with fossil fuels, would mean further imports of fuel as well as a rise in CO 2 emissions. At the same time, several small district-heating companies one suffering from high heating-prices. Typically, the price in small towns is 20-50% higher than the price in large urban areas. Consequently, alternative strategies should be considered. This article analyses the conditions for one such strategy, namely the replacement of boilers in the existing district-heating supplies with combined heat-and-power production (CHP). Compared with new power stations, fuel can be saved and CO 2 -emissions reduced. Also this strategy can be used to level the difference between low heating prices in the large urban areas and high prices in small towns and villages. (Author)

  11. BANK MANAGEMENT STRATEGIES REGARDING THE ATTRACTION OF POPULATION SAVINGS BASED ON THE "FINANCIAL SITUATION OF THE ROMANIAN HOUSEHOLDS" POLL

    OpenAIRE

    NICULESCU-ARON Ileana Gabriela; MIHAESCU Constanta; CAPLESCU Raluca

    2012-01-01

    Financing economic recovery is mainly based on the household sector savings, thus anti-crisis governmental programmes should be based on rigorous knowledge regarding saving and consumption behaviours. Selective studies allow for obtaining quick and pertinent results regarding these behaviours. The present study is based on a poll designed for assessing the level of financial education and financial situation of the population, and their impact on savings and preference for various saving inst...

  12. Goal clarity and financial planning activities as determinants of retirement savings contributions.

    Science.gov (United States)

    Stawski, Robert S; Hershey, Douglas A; Jacobs-Lawson, Joy M

    2007-01-01

    Retirement counselors, financial service professionals, and retirement intervention specialists routinely emphasize the importance of developing clear goals for the future; however, few empirical studies have focused on the benefits of retirement goal setting. In the present study, the extent to which goal clarity and financial planning activities predict retirement savings practices was examined among 100 working adults. Path analysis techniques were used to test two competing models, both of which were designed to predict savings contributions. Findings provide support for the model in which retirement goal clarity is a significant predictor of planning practices, and planning, in turn, predicts savings tendencies. Two demographic variables-income and age-were also revealed to be important elements of the model, with income accounting for roughly half of the explained variance in savings contributions. The results of this study have implications for the development of age-based models of planning, as well as implications for retirement counselors and financial planners who advise workers on long-term saving strategies.

  13. Intrinsic Changes: Energy Saving Behaviour among Resident University Students

    Science.gov (United States)

    Black, Rosemary; Davidson, Penny; Retra, Karen

    2010-01-01

    This paper presents the results of a study that explored the effectiveness of three intervention strategies in facilitating energy saving behaviour among resident undergraduate university students. In contrast to a dominant practice of motivating with rewards or competition this study sought to appeal to students' intrinsic motivations. An…

  14. RF Power Transfer, Energy Harvesting, and Power Management Strategies

    Science.gov (United States)

    Abouzied, Mohamed Ali Mohamed

    sources in the far field, dc energy combining, wireless power transfer in the near field, the underlying power management strategies, and the integration on silicon. This integration is the ultimate goal for cheap solutions to enable the technology for broader use. All systems were designed, implemented and tested to demonstrate proof-of concept prototypes.

  15. Optimized control strategy for crowbarless solid state modular power supply

    International Nuclear Information System (INIS)

    Upadhyay, R.; Badapanda, M.K.; Tripathi, A.; Hannurkar, P.R.; Pithawa, C.K.

    2009-01-01

    Solid state modular power supply with series connected IGBT based power modules have been employed as high voltage bias power supply of klystron amplifier. Auxiliary compensation of full wave inverter bridge with ZVS/ZCS operations of all IGBTs over entire operating range is incorporated. An optimized control strategy has been adopted for this power supply needing no output filter, making this scheme crowbarless and is presented in this paper. DSP based fully digital control with same duty cycle for all power modules, have been incorporated for regulating this power supply along with adequate protection features. Input to this power supply is taken directly from 11 kV line and the input system is intentionally made 24 pulsed to reduce the input harmonics, improve the input power factor significantly, there by requiring no line filters. Various steps have been taken to increase the efficiency of major subsystems, so as to improve the overall efficiency of this power supply significantly. (author)

  16. Cofiring versus biomass-fired power plants: GHG (Greenhouse Gases) emissions savings comparison by means of LCA (Life Cycle Assessment) methodology

    International Nuclear Information System (INIS)

    Sebastian, F.; Royo, J.; Gomez, M.

    2011-01-01

    One way of producing nearly CO 2 free electricity is by using biomass as a combustible. In many cases, removal of CO 2 in biomass grown is almost the same as the emissions for the bioelectricity production at the power plant. For this reason, bioelectricity is generally considered CO 2 neutral. For large-scale biomass electricity generation two alternatives can be considered: biomass-only fired power plants, or cofiring in an existing coal power plant. Among other factors, two important aspects should be analyzed in order to choose between the two options. Firstly, which is the most appealing alternative if their Greenhouse Gases (GHG) Emissions savings are taken into account. Secondly, which biomass resource is the best, if the highest impact reduction is sought. In order to quantify all the GHG emissions related to each system, a Life Cycle Assessment (LCA) methodology has been performed and all the processes involved in each alternative have been assessed in a cradle-to-grave manner. Sensitivity analyses of the most dominant parameters affecting GHG emissions, and comparisons between the obtained results, have also been carried out.

  17. Economic assessment of nuclear power plant operation with regard to effective use of nuclear fuel

    International Nuclear Information System (INIS)

    Svec, P.; Raninec, S.; Mizov, J.

    1988-01-01

    The essential preconditions are discussed for the better utilization of fuel in nuclear power plants. The MORNAP program which models the operation of the reactor is used for assessing the consequences of various fuel utilization strategies on technical and economic parameters of WWER-440 nuclear power plant operation. Some results of model calculation are given for the third and fourth units of the Jaslovske Bohunice nuclear power plant. The calculations have served for the economic assessment of the transition of part of the nuclear fuel from a three-campaign to a four-campaign cycle. This transition reduces fuel costs by 1.7%. The implementation of this strategy on a larger scale is expected to save 7 to 9% of fuel costs. (Z.M.). 2 tabs., 7 refs

  18. Power generation assets. Energy constraints, upper bounds and hedging strategies

    Energy Technology Data Exchange (ETDEWEB)

    Enge, Thomas

    2010-09-20

    The overall topic of this thesis is the valuation of power generation assets under energy and risk constraints. Our focus is on the modeling aspect i.e. to find the right balance between accuracy and computational feasibility. We define a new not yet investigated unit commitment problem that introduces an energy constraint to a thermal power plant. We define a continuous stochastic dynamic program with a nested mixed integer program (MIP). We introduce a fast implementation approach by replacing the MIP with an efficient matrix calculation and use principal component analysis to reduce the number of risk factors. We also provide a fast heuristic valuation approach for comparison. As both models can only provide lower bounds of the asset value, we investigate the theory of upper bounds for a proper validation of our power plant results. We review the primal dual algorithm for swing options by Meinshausen and Hambly and in particular clarify their notation and implementation. Then we provide an extension for swing options with multiple exercises at the same stage that we developed together with Prof. Bender, University of Braunschweig. We outline Prof. Bender's proof and describe the implementation in detail. Finally we provide a risk analysis for our thermal power plant. In particular we investigate strategies to reduce spot price risk to which power plants are significantly exposed. First, we focus on the measurement of spot price risk and propose three appropriate risk figures (Forward delta as opposed to Futures delta, synthetic spot delta and Earnings-at-Risk) and illustrate their application using a business case. Second we suggest risk mitigation strategies for both periods, before and in delivery. The latter tries to alter the dispatch policy i.e. pick less risky hours and accept a (desirably only slightly) smaller return. We introduce a benchmark that weighs risk versus return and that we will call EaR-efficient option value. We propose a mitigation

  19. Subjective discount rates in the general population and their predictive power for energy saving behavior

    International Nuclear Information System (INIS)

    Bruderer Enzler, Heidi; Diekmann, Andreas; Meyer, Reto

    2014-01-01

    Why do people sometimes refrain from saving energy even if it would pay off in monetary terms? Subjective discount rates present one possible explanation for this lack of foresight, but little is known about their level and reliability in the general population. With regard to behavior, persons with lower discount rates are expected to accept additional costs upfront more readily than those with higher discount rates. Based on a representative nation-wide study, the Swiss Environmental Survey 2007, and a follow-up survey, our analyses reveal that on average subjective discount rates are well above market interest rates and moderately stable over a time interval of four years. Income and education are negatively correlated with discount rates. Contrary to expectations, we did not find convincing support for an impact of discount rates on energy saving behavior. - Highlights: • Results of a large panel study in Switzerland. • Mean subjective discount rates in population are well above market interest rates. • Subjective discount rates are moderately stable over four years. • Theory suggests impact of subjective discount rates on energy saving behavior. • However, subjective discount rates do not contribute to explanation of energy saving behavior

  20. Saving can save from death anxiety: mortality salience and financial decision-making.

    Science.gov (United States)

    Zaleskiewicz, Tomasz; Gasiorowska, Agata; Kesebir, Pelin

    2013-01-01

    Four studies tested the idea that saving money can buffer death anxiety and constitute a more effective buffer than spending money. Saving can relieve future-related anxiety and provide people with a sense of control over their fate, thereby rendering death thoughts less threatening. Study 1 found that participants primed with both saving and spending reported lower death fear than controls. Saving primes, however, were associated with significantly lower death fear than spending primes. Study 2 demonstrated that mortality primes increase the attractiveness of more frugal behaviors in save-or-spend dilemmas. Studies 3 and 4 found, in two different cultures (Polish and American), that the activation of death thoughts prompts people to allocate money to saving as opposed to spending. Overall, these studies provided evidence that saving protects from existential anxiety, and probably more so than spending.

  1. Saving can save from death anxiety: mortality salience and financial decision-making.

    Directory of Open Access Journals (Sweden)

    Tomasz Zaleskiewicz

    Full Text Available Four studies tested the idea that saving money can buffer death anxiety and constitute a more effective buffer than spending money. Saving can relieve future-related anxiety and provide people with a sense of control over their fate, thereby rendering death thoughts less threatening. Study 1 found that participants primed with both saving and spending reported lower death fear than controls. Saving primes, however, were associated with significantly lower death fear than spending primes. Study 2 demonstrated that mortality primes increase the attractiveness of more frugal behaviors in save-or-spend dilemmas. Studies 3 and 4 found, in two different cultures (Polish and American, that the activation of death thoughts prompts people to allocate money to saving as opposed to spending. Overall, these studies provided evidence that saving protects from existential anxiety, and probably more so than spending.

  2. Uncertainty modeling of CCS investment strategy in China's power sector

    International Nuclear Information System (INIS)

    Zhou, Wenji; Zhu, Bing; Fuss, Sabine; Szolgayova, Jana; Obersteiner, Michael; Fei, Weiyang

    2010-01-01

    The increasing pressure resulting from the need for CO 2 mitigation is in conflict with the predominance of coal in China's energy structure. A possible solution to this tension between climate change and fossil fuel consumption fact could be the introduction of the carbon capture and storage (CCS) technology. However, high cost and other problems give rise to great uncertainty in R and D and popularization of carbon capture technology. This paper presents a real options model incorporating policy uncertainty described by carbon price scenarios (including stochasticity), allowing for possible technological change. This model is further used to determine the best strategy for investing in CCS technology in an uncertain environment in China and the effect of climate policy on the decision-making process of investment into carbon-saving technologies.

  3. Application of Waste Heat Recovery Energy Saving Technology in Reform of UHP-EAF

    Science.gov (United States)

    Zhao, J. H.; Zhang, S. X.; Yang, W.; Yu, T.

    2017-08-01

    The furnace waste heat of a company’s existing 4 × 100t ultra-high-power electric arc furnaces is not used and discharged directly of the situation has been unable to meet the national energy-saving emission reduction requirements, and also affected their own competitiveness and sustainable development. In order to make full use of the waste heat of the electric arc furnace, this paper presents an the energy-saving transformation program of using the new heat pipe boiler on the existing ultra-high-power electric arc furnaces for recovering the waste heat of flue gas. The results show that after the implementation of the project can save energy equivalent to 42,349 tons of standard coal. The flue gas waste heat is fully utilized and dust emission concentration is accorded with the standard of Chinese invironmental protection, which have achieved good results.

  4. Model for Determining Geographical Distribution of Heat Saving Potentials in Danish Building Stock

    DEFF Research Database (Denmark)

    Petrovic, Stefan; Karlsson, Kenneth Bernard

    2014-01-01

    Since the global oil crisis in the 1970s, Denmark has followed a path towards energy independency by continuously improving its energy efficiency and energy conservation. Energy efficiency was mainly tackled by introducing a high number of combined heat and power plants in the system, while energy...... conservation was predominantly approached by implementing heat saving measures. Today, with the goal of 100% renewable energy within the power and heat sector by the year 2035, reductions in energy demand for space heating and the preparation of domestic hot water remain at the top of the agenda in Denmark....... A highly detailed model for determining heat demand, possible heat savings and associated costs in the Danish building stock is presented. Both scheduled and energy-saving renovations until year 2030 have been analyzed. The highly detailed GIS-based heat atlas for Denmark is used as a container for storing...

  5. Electricity-saving measures for electrical drives - Market analysis; Massnahmen zum Stromsparen bei elektrischen Antrieben. Marktanalyse in der Industrie. Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Baumgartner, W.; Ebert Bolla, O.; Puenzieux, P.

    2006-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of work done on an empirical analysis of the results of a small-scale survey of industries as well as on various interviews with experts. Topics covered include the number of electrical motors in use in Switzerland, the number held in reserve, power consumption, part-load and over-dimensioning, operational factors, control strategies and the use of standardised motors. The data collected is presented in tabular and graphical form. Possibilities of making savings are discussed, as are obstacles to such work. Finally, ideas for an efficiency campaign are presented.

  6. An energy saving mechanism of EPON networks for real time video transmission

    Science.gov (United States)

    Liu, Chien-Ping; Wu, Ho-Ting; Chiang, Yun-Ting; Chien, Shieh-Chieh; Ke, Kai-Wei

    2015-07-01

    Modern access networks are constructed widely by passive optical networks (PONs) to meet the growing bandwidth demand. However, higher bandwidth means more energy consumption. To save energy, a few research works propose the dual-mode energy saving mechanism that allows the ONU to operate between active and sleep modes periodically. However, such dual-mode energy saving design may induce unnecessary power consumption or packet delay increase in the case where only downstream data exist for most of the time. In this paper, we propose a new tri-mode energy saving scheme for Ethernet PON (EPON). The new tri-mode energy saving design, combining the dual-mode saving mechanism with the doze mode, allows the ONU to switch among these three modes alternatively. In the doze mode, the ONU may receive downstream data while keeping its transmitter close. Such scenario is often observed for real time video downstream transmission. Furthermore, the low packet delay of high priority upstream data can be attained through the use of early wake-up mechanism employed in both energy saving modes. The energy saving and system efficiency can thus be achieved jointly while maintaining the differentiated QoS for data with various priorities. Performance results via simulation have demonstrated the effectiveness of such mechanism.

  7. Smart — STATCOM control strategy implementation in wind power plants

    DEFF Research Database (Denmark)

    Sintamarean, Nicolae Christian; Cantarellas, Antoni Mir; Miranda, H.

    2012-01-01

    High penetration of wind energy into the grid may introduce stability and power quality problems due to the fluctuating nature of the wind and the increasing complexity of the power system. By implementing advanced functionalities in power converters, it is possible to improve the performance...... of the wind farm and also to provide grid support, as it is required by the grid codes. One of the main compliance difficulties that can be found in such power plants are related to reactive power compensation and to keep the harmonics content between the allowed limits, even if the power of the WPP...... converters is increasing. This paper deals with an advanced control strategy design of a three-level converter performing STATCOM and Active Filter functionalities. The proposed system is called Smart-STATCOM since it has the capability of self-controlling reactive power and harmonic voltages at the same...

  8. Energy Savings Lifetimes and Persistence

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, Ian M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Schiller, Steven R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Todd, Annika [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Billingsley, Megan A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Goldman, Charles A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Schwartz, Lisa C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-02-01

    This technical brief explains the concepts of energy savings lifetimes and savings persistence and discusses how program administrators use these factors to calculate savings for efficiency measures, programs and portfolios. Savings lifetime is the length of time that one or more energy efficiency measures or activities save energy, and savings persistence is the change in savings throughout the functional life of a given efficiency measure or activity. Savings lifetimes are essential for assessing the lifecycle benefits and cost effectiveness of efficiency activities and for forecasting loads in resource planning. The brief also provides estimates of savings lifetimes derived from a national collection of costs and savings for electric efficiency programs and portfolios.

  9. Model for Determining Geographical Distribution of Heat Saving Potentials in Danish Building Stock

    Directory of Open Access Journals (Sweden)

    Stefan Petrovic

    2014-02-01

    Full Text Available Since the global oil crisis in the 1970s, Denmark has followed a path towards energy independency by continuously improving its energy efficiency and energy conservation. Energy efficiency was mainly tackled by introducing a high number of combined heat and power plants in the system, while energy conservation was predominantly approached by implementing heat saving measures. Today, with the goal of 100% renewable energy within the power and heat sector by the year 2035, reductions in energy demand for space heating and the preparation of domestic hot water remain at the top of the agenda in Denmark. A highly detailed model for determining heat demand, possible heat savings and associated costs in the Danish building stock is presented. Both scheduled and energy-saving renovations until year 2030 have been analyzed. The highly detailed GIS-based heat atlas for Denmark is used as a container for storing data about physical properties for 2.5 million buildings in Denmark. Consequently, the results of the analysis can be represented on a single building level. Under the assumption that buildings with the most profitable heat savings are renovated first, the consequences of heat savings for the economy and energy system have been quantified and geographically referenced. The possibilities for further improvements of the model and the application to other geographical regions have been discussed.

  10. Spending to save

    DEFF Research Database (Denmark)

    Larsen, Anders

    2013-01-01

    the energy distribution companies meet their overall saving obligation, the net savings impact are about a third of the savings reported by the obligated parties. Further it was found that while energy savings in the public and business sector have a high net impact, some subsidies given under the EEO...... perspective. The evaluation has resulted in noticeable adjustments of the design of the Danish EEO, e.g. introduction of a 1 year payback-time limit for projects receiving subsidies, a minimum baseline for insulation products, and specification of documentation requirements....

  11. Energy-Saving in Brew-Rectification

    Directory of Open Access Journals (Sweden)

    N. I. Ulyanau

    2008-01-01

    Full Text Available The paper investigates dynamics of rectification process on one plate of a column. The basic channels controlling brew-rectification process are described in the paper.The paper also considers problems pertaining to synthesis of an adaptive system that controls non-stationary objects with delay. Synthesis of adaptive systems that automatically control product quality and saving on power resources and productivity with the help of the second method of Lyapunov has been carried out in the paper.Industrial introduction of the given automatic control system of technological process shall permit to increase productivity of a rectification (10–15 %, to decrease specific power consumption by (5–10 % while preserving the specified quality of rectified ethyl alcohol and decrease alcohol losses with luting water and malt-residue.

  12. Energy impacts of heat island reduction strategies in the Greater Toronto Area, Canada; FINAL

    International Nuclear Information System (INIS)

    Konopacki, Steven; Akbari, Hashem

    2001-01-01

    In 2000, the Toronto Atmospheric Fund (TAF) embarked on an initiative to quantify the potential benefits of Heat Island Reduction (HIR) strategies (shade trees, reflective roofs and pavements) in reducing cooling energy use in buildings, lowering the ambient air temperature and improve air quality. This report summarizes the efforts of Lawrence Berkeley National Laboratory (LBNL) to assess the impacts of HIR measures on building cooling- and heating-energy use. We discuss our efforts to calculate annual energy savings and peak-power avoidance of HIR strategies in the building sector of the Greater Toronto Area. The analysis is focused on three major building types that offer most saving potentials: residence, office and retail store. Using an hourly building energy simulation model, we quantify the energy saving potentials of (1) using cool roofs on individual buildings[direct effect], (2) planting deciduous shade trees near south and west walls of building[direct effect], (3) planting coniferous wind-shielding vegetation near building[direct effect], (4) ambient cooling by a large-scale program of urban reforestation with reflective building roofs and pavements[indirect effect], (5) and the combined direct and indirect effects. Results show potential annual energy savings of over$11M (with uniform residential and commercial electricity and gas prices of$0.084/kWh and$5.54/GJ) could be realized by ratepayers from the combined direct and indirect effects of HIR strategies. Of that total, about 88 percent was from the direct impact roughly divided equally among reflective roofs, shade trees and wind-shielding, and the remainder (12 percent) from the indirect impact of the cooler ambient air temperature. The residential sector accounts for over half (59 percent) of the total, offices 13 percent and retail stores 28 percent. Savings from cool roofs were about 20 percent, shade trees 30 percent, wind shielding of tree 37 percent, and indirect effect 12 percent. These

  13. Benchmarking of Constant Power Generation Strategies for Single-Phase Grid-Connected Photovoltaic Systems

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Blaabjerg, Frede

    2018-01-01

    strategies based on: 1) a power control method (P-CPG), 2) a current limit method (I-CPG) and 3) the Perturb and Observe algorithm (P&O-CPG). However, the operational mode changes (e.g., from the maximum power point tracking to a CPG operation) will affect the entire system performance. Thus, a benchmarking...... of the presented CPG strategies is also conducted on a 3-kW single-phase grid-connected PV system. Comparisons reveal that either the P-CPG or I-CPG strategies can achieve fast dynamics and satisfactory steady-state performance. In contrast, the P&O-CPG algorithm is the most suitable solution in terms of high...

  14. Environment, renewable sources and NPPs: Strategy of Slovak Republic for the back end of nuclear power

    International Nuclear Information System (INIS)

    Timulak, J.

    2009-01-01

    The term 'back end of nuclear power' means set of activities corresponding to the final stage of utilizing the nuclear energy for peaceful purposes, or at the border of nuclear facilities with the environment. Strategy of back end of nuclear power is a basic document that specifies strategy of the Slovak Republic and all relevant subjects for the next five years in detail and for the period up to 2025 in general terms, with the prospect till the end of 21 st century. It provides proposals for implementation of the back end strategy in accordance with requirements for the health and environmental protection so that its consequences are not unacceptably transferred to next generations. The goal of the back end strategy is: - to set acceptable bases back end of nuclear power in Slovakia; - to create framework for decision-making in financial covering of the strategy activities; - to provide information on conceptual solutions of back end of nuclear power to all relevant subjects and to the public. (author)

  15. Financing strategy for Indonesian Nuclear Power Project

    International Nuclear Information System (INIS)

    Subki, I.M.; Arbie, B.; Adiwardojo; Seotrisnanto, A.Y.

    1998-01-01

    In anticipation of the introduction in the early 2000s of a nuclear power plant, the Government of Indonesia (GOI), through the National Atomic Energy Agency (BATAN) , has formulated a Bid Invitation Specification (BIS) in parallel with the completion of the NPP Feasibility Study. This BIS formulation assumed an open international tender for the first unit of the NPP with project financing as a conventional loan. The GOI's recent policy is to minimize government financial support for power development. This paper summarizes a financing strategy for the Indonesian NPP project to make the NPP economically viable, and provides a general discussion on project financing using a conventional approach, Build--Own-Operate (BOO) and a counter-purchase approach. Innovative approaches for financing are still being pursued in order to obtain an optimum solution for investors and owners, to fulfill the Indonesian government's requirements. (author)

  16. Reactive power and voltage control strategy based on dynamic and adaptive segment for DG inverter

    Science.gov (United States)

    Zhai, Jianwei; Lin, Xiaoming; Zhang, Yongjun

    2018-03-01

    The inverter of distributed generation (DG) can support reactive power to help solve the problem of out-of-limit voltage in active distribution network (ADN). Therefore, a reactive voltage control strategy based on dynamic and adaptive segment for DG inverter is put forward to actively control voltage in this paper. The proposed strategy adjusts the segmented voltage threshold of Q(U) droop curve dynamically and adaptively according to the voltage of grid-connected point and the power direction of adjacent downstream line. And then the reactive power reference of DG inverter can be got through modified Q(U) control strategy. The reactive power of inverter is controlled to trace the reference value. The proposed control strategy can not only control the local voltage of grid-connected point but also help to maintain voltage within qualified range considering the terminal voltage of distribution feeder and the reactive support for adjacent downstream DG. The scheme using the proposed strategy is compared with the scheme without the reactive support of DG inverter and the scheme using the Q(U) control strategy with constant segmented voltage threshold. The simulation results suggest that the proposed method has a significant improvement on solving the problem of out-of-limit voltage, restraining voltage variation and improving voltage quality.

  17. Performance analysis of proposed hybrid air conditioning and humidification–dehumidification systems for energy saving and water production in hot and dry climatic regions

    International Nuclear Information System (INIS)

    Nada, S.A.; Elattar, H.F.; Fouda, A.

    2015-01-01

    Highlights: • Integrative air-conditioning (A/C) and humidification–dehumidification desalination systems are proposed. • Effects of operating parameters on the proposed systems are investigated. • System configurations that have the highest fresh water production rate, power saving and total cost saving are identified. - Abstract: Performance of integrative air-conditioning (A/C) and humidification–dehumidification desalination systems proposed for hot and dry climatic regions is theoretically investigated. The proposed systems aim to energy saving and systems utilization in fresh water production. Four systems with evaporative cooler and heat recovery units located at different locations are proposed, analyzed and evaluated at different operating parameters (fresh air ratio, supply air temperature and outside air wet bulb temperature). Other two basic systems are used as reference systems in proposed systems assessment. Fresh water production rate, A/C cooling capacity, A/C electrical power consumption, saving in power consumptions and total cost saving (TCS) parameters are used for systems evaluations and comparisons. The results show that (i) the fresh water production rates of the proposed systems increase with increasing fresh air ratio, supply air temperature and outdoor wet bulb temperature, (ii) powers saving of the proposed systems increase with increasing fresh air ratio and supply air temperature and decreasing of the outdoor air wet bulb temperature, (iii) locating the evaporative cooling after the fresh air mixing remarkably increases water production rate, and (vi) incorporating heat recovery in the air conditioning systems with evaporative cooling may adversely affect both of the water production rate and the total cost saving of the system. Comparison study has been presented to identify systems configurations that have the highest fresh water production rate, highest power saving and highest total cost saving. Numerical correlations for

  18. Cyber attacks against state estimation in power systems: Vulnerability analysis and protection strategies

    Science.gov (United States)

    Liu, Xuan

    Power grid is one of the most critical infrastructures in a nation and could suffer a variety of cyber attacks. With the development of Smart Grid, false data injection attack has recently attracted wide research interest. This thesis proposes a false data attack model with incomplete network information and develops optimal attack strategies for attacking load measurements and the real-time topology of a power grid. The impacts of false data on the economic and reliable operations of power systems are quantitatively analyzed in this thesis. To mitigate the risk of cyber attacks, a distributed protection strategies are also developed. It has been shown that an attacker can design false data to avoid being detected by the control center if the network information of a power grid is known to the attacker. In practice, however, it is very hard or even impossible for an attacker to obtain all network information of a power grid. In this thesis, we propose a local load redistribution attacking model based on incomplete network information and show that an attacker only needs to obtain the network information of the local attacking region to inject false data into smart meters in the local region without being detected by the state estimator. A heuristic algorithm is developed to determine a feasible attacking region by obtaining reduced network information. This thesis investigates the impacts of false data on the operations of power systems. It has been shown that false data can be designed by an attacker to: 1) mask the real-time topology of a power grid; 2) overload a transmission line; 3) disturb the line outage detection based on PMU data. To mitigate the risk of cyber attacks, this thesis proposes a new protection strategy, which intends to mitigate the damage effects of false data injection attacks by protecting a small set of critical measurements. To further reduce the computation complexity, a mixed integer linear programming approach is also proposed to

  19. Maintenance cost savings - snubber elimination with limit stops

    International Nuclear Information System (INIS)

    Cloud, R.L.; Taylor, W.H.

    1993-01-01

    'Active' snubbers can be replaced with 'passive' Limit Stops using two separate strategies. One is a straightforward piping re-analysis to optimize the number of dynamic supports and replace remaining snubbers with Limit Stops. A second approach is to take implicit advantage of the margins afforded by the ASME Code Case N-411 reduced damping ratios and simply replace snubbers one-for-one with no re-analysis. Both methods result in major maintenance cost savings and both have been discussed with the NRC. Approaches to maintenance cost reduction using these strategies are discussed in this paper

  20. Brazil’s Soft-Power Strategy: The Political Aspirations of South–South Development Cooperation

    DEFF Research Database (Denmark)

    Bry, Sandra

    2017-01-01

    By trading upon the principles of South-South cooperation, Brazil is widely viewed as having gained a positive image worldwide. Brazil’s South-South development cooperation was one of the foreign policy instruments it used to raise this profile. However, studies of the generation of soft power...... are still lacking in the international relations literature,and where empirical research exists it focuses more on the results of soft power strategies than on how soft power is created. Therefore,this article explores how Brazil’s soft power strategy is conceptualized in Brazil’s development cooperation...... of its cooperation agency and guided it towards sectors and targets that contribute to the creation of positive outcomes. This article contributes to the debate on the state’s behavior in soft power, that is, the ‘behavior’ of the Brazilian government in the design of its cooperation agency’s activities...

  1. Exploring the time-saving bias: How drivers misestimate time saved when increasing speed

    Directory of Open Access Journals (Sweden)

    Eyal Peer

    2010-12-01

    Full Text Available According to the time-saving bias, drivers underestimate the time saved when increasing from a low speed and overestimate the time saved when increasing from a relatively high speed. Previous research used a specific type of task --- drivers were asked to estimate time saved when increasing speed and to give a numeric response --- to show this. The present research conducted two studies with multiple questions to show that the time-saving bias occurs in other tasks. Study 1 found that drivers committed the time-saving bias when asked to estimate (a the time saved when increasing speed or (b the distance that can be completed at a given time when increasing speed or (c the speed required to complete a given distance in decreasing times. Study 2 showed no major differences in estimations of time saved compared to estimations of the remaining journey time and also between responses given on a numeric scale versus a visual analog scale. Study 3 tested two possible explanations for the time-saving bias: a Proportion heuristic and a Differences heuristic. Some evidence was found for use of the latter.

  2. Strategy and system of fire protection at Guangdong Daya Bay Nuclear Power Plant

    International Nuclear Information System (INIS)

    Zhou Weihong

    1999-12-01

    The fire protection is an important safety issue of nuclear power utilities. The author depicts the strategy and management system of fire protection implemented successfully at Guangdong Daya Bay Nuclear Power Plant of China

  3. Establishment of windows-based load management system for electricity cost savings in competitive electricity markets

    International Nuclear Information System (INIS)

    Chung, K.H.; Kim, B.H.; Hur, D.

    2007-01-01

    For electricity markets to function in a truly competitive and efficient manner, it is not enough to focus solely on improving the efficiencies of power supply. To recognize price-responsive load as a reliability resource, the customer must be provided with price signals and an instrument to respond to these signals, preferably automatically. This paper attempts to develop the Windows-based load management system in competitive electricity markets, allowing the user to monitor the current energy consumption or billing information, to analyze the historical data, and to implement the consumption strategy for cost savings with nine possible scenarios adopted. Finally, this modeling framework will serve as a template containing the basic concepts that any load management system should address. (author)

  4. Real And Reactive Power Saving In Three Phase Induction Machine Using Star-Delta Switching Schemes

    Directory of Open Access Journals (Sweden)

    Ramesh Daravath

    2017-04-01

    Full Text Available Induction machines are the most commonly used industrial drives for variety of applications. It has been estimated that induction motors consumes approximately 50 of all the electric energy generated. Further in the area of renewable energy sources such as wind or bio-mass energy induction machines have been found suitable for functioning as generators. In this context it may be mentioned that a star-delta switching is common for the starting of three-phase induction motor. Now it is proposed to use this star-delta switching for energy conservation of induction machines i.e. at times of reduced loads the machine switched back to star connection. Using a three-phase 400 V 50 Hz 4-pole induction machine it has been demonstrated that the star-delta switching of stator winding of three-phase induction machine motor generator operations reconnected in star at suitable reduced loads with a switching arrangement can result in improved efficiency and power factor as compared to a fixed delta or star connection. The predetermined values along with the experimental results have also been presented in this report. A simulation program has been developed for the predetermination of performance of the three-phase induction machine using exact equivalent circuit. A case study on a 250 kW 400 V 4-pole three-phase induction machine operated with different load cycles reveals the significant real and reactive power savings that could be obtained in the present proposal.

  5. Model-based power control strategy development of a fuel cell hybrid vehicle

    Energy Technology Data Exchange (ETDEWEB)

    Haitao, Yun [School of Automobile and Traffic, Qingdao Technological University, Qingdao Shandong 266033 (China); School of Automobile, Tongji University, ShangHai 201804 (China); Yulan, Zhao [School of Automobile and Traffic, Qingdao Technological University, Qingdao Shandong 266033 (China); Zechang, Sun; Gang, Wan [School of Automobile, Tongji University, ShangHai 201804 (China)

    2008-06-01

    An integrated procedure for math modeling and power control strategy design for a fuel cell hybrid vehicle (FCHV) is presented in this paper. Dynamic math model of the powertrain is constructed firstly, which includes four modules: fuel cell engine, DC/DC inverter, motor-driver, and power battery. Based on the mathematic model, a power control principle is designed, which uses full-states closed-loop feedback algorithm. To implement full-states feedback, a Luenberger state observer is designed to estimate open circuit voltage (OCV) of the battery, which make the control principle not sensitive to the battery SOC (state of charge) estimated error. Full-states feedback controller is then designed through analyzing step responding of the powertrain and test data. At last of the paper, the results of simulation and field test are illustrated. The results show that the power control strategy designed takes into account the performance and economy characteristics of components of the FCHV powertrain and achieves the control object excellently. (author)

  6. Dispatching strategies for coordinating environmental awareness and risk perception in wind power integrated system

    International Nuclear Information System (INIS)

    Jin, Jingliang; Zhou, Dequn; Zhou, Peng; Qian, Shuqu; Zhang, Mingming

    2016-01-01

    Wind power plays a significant role in economic and environmental operation of electric power system. Meanwhile, the variability and uncertainty characteristics of wind power generation bring technical and economical challenges for power system operation. In order to harmonize the relationship between environmental protection and risk management in power dispatching, this paper presents a stochastic dynamic economic emission dispatch model combining risk perception with environmental awareness of decision-makers by following the principle of chance-constrained programming. In this power dispatching model, the description of wind power uncertainty is derived from the probability statistic character of wind speed. Constraints-handling techniques as a heuristic strategy are embedded into non-dominated sorting genetic algorithm-II. In addition, more information is digested from the Pareto optimum solution set by cluster analysis and fuzzy set theory. The simulation results eventually demonstrate that the increase of the share of wind power output will bring higher risk, though it is beneficial for economic cost and environmental protection. Since different risk perception and environmental awareness can possibly lead to diverse non-dominated solutions, decision-makers may choose an appropriate dispatching strategy according to their specific risk perception and environmental awareness. - Highlights: • A dispatch model combining environmental awareness and risk perception is proposed. • The uncertain characteristic of available wind power is determined. • Constraints-handling techniques are embedded into genetic algorithm. • An appropriate decision-making method is designed. • Dispatching strategies can be coordinated by the proposed model and method.

  7. Energy Efficiency Programs in K-12 Schools: A Guide to Developing and Implementing Greenhouse Gas Reduction Programs. Local Government Climate and Energy Strategy Series

    Science.gov (United States)

    US Environmental Protection Agency, 2011

    2011-01-01

    Saving energy through energy efficiency improvements can cost less than generating, transmitting, and distributing energy from power plants, and provides multiple economic and environmental benefits. Local governments can promote energy efficiency in their jurisdictions by developing and implementing strategies that improve the efficiency of…

  8. Interference Effects Redress over Power-Efficient Wireless-Friendly Mesh Networks for Ubiquitous Sensor Communications across Smart Cities.

    Science.gov (United States)

    Santana, Jose; Marrero, Domingo; Macías, Elsa; Mena, Vicente; Suárez, Álvaro

    2017-07-21

    Ubiquitous sensing allows smart cities to take control of many parameters (e.g., road traffic, air or noise pollution levels, etc.). An inexpensive Wireless Mesh Network can be used as an efficient way to transport sensed data. When that mesh is autonomously powered (e.g., solar powered), it constitutes an ideal portable network system which can be deployed when needed. Nevertheless, its power consumption must be restrained to extend its operational cycle and for preserving the environment. To this end, our strategy fosters wireless interface deactivation among nodes which do not participate in any route. As we show, this contributes to a significant power saving for the mesh. Furthermore, our strategy is wireless-friendly, meaning that it gives priority to deactivation of nodes receiving (and also causing) interferences from (to) the rest of the smart city. We also show that a routing protocol can adapt to this strategy in which certain nodes deactivate their own wireless interfaces.

  9. Power shopping - practical advice and cost-saving alternatives

    International Nuclear Information System (INIS)

    Anthofer, J.

    1999-01-01

    Encore Energy Solutions is a power consulting company which operates in California, Alberta and Ontario. The company manages electricity portfolios, sells risk management instruments and works with end users to lower power costs. It also helps utilities manage the evolution to a competitive energy market. In this presentation, a series of overhead viewgraphs were used to explain the roles of different players in Ontario's electric power industry, including generators, retailers, distributors, wholesale sellers, transmitters, wholesale consumers, independent market operators (IMOs), and consultants. The challenges facing municipal electric utilities regarding the wires business and retail services were also discussed. The trends in today's evolving power market were highlighted. These included price elasticity, load dispatch, granularity, long- and short-term volatility, gas prices, day/night spread, transmission tariffs, congestion and cost of capital. A graph depicting volatility term structures for electricity, natural gas and crude oil suggests that instantaneous volatility of power is almost infinite. Issues regarding risk management in terms of shareholder's portfolio values were also discussed. 17 figs

  10. Strategies for sustainable development of the Polish electric power system

    International Nuclear Information System (INIS)

    Janiczek, R.

    1996-01-01

    The key features of sustainable development of the Polish electric power industry are discussed. Priorities and limitations for changes and power demand forecasts are described. Results of least-cost planning for existing power plants' modernization and generation expansion with environmental impacts are presented. The least-cost strategy is given by the optimal upgrades of older plants until year 2002 and by expansion of gas-fired units. The limited availability of gas after 2010 will lead to the construction of new coal-fired plants. For the next planning process, an integrated resource planning methodology is proposed, which includes dynamic optimization of supply and demand side options. Innovative mechanisms are shown to overcome barriers of development like long-terms contracts and decentralization of the power system planning process. (author)

  11. Prospects of nuclear power in fossil fuel saving

    International Nuclear Information System (INIS)

    Chernavskij, S.Ya.

    1984-01-01

    Economic aspects of the World energy situation are considered. The growth in the world prices for energy and energy resources has demanded to reconstruct the structure of both consumers and primary energy resources. The nuclear power development is one of the most important aspects of this reconstruction. In connection with its development the acceptability of nuclear power technology and possible spheres of its application in different fields of power engineering are considered. When discussing these problems one pays the main attention to the psychological effect and potential measures for its compensation. A forecast estimate is given of specific capital investments in and expenditures on electric energy production for NPPs and conventional power stations for the considered period of 30 years. The estimates are differentiated for the European and Asian parts of the country. The problems of developing nuclear central heating-and-power plants and nuclear thermal stations are discussed. It is pointed out that presently no sufficient experience has been gained in their commerical operation to discuss for sure the prospects of their wide-scale utilization. Results of calculations are presented showing that in the range of high-temperature processes the use of electric energy based on the nuclear power development is more efficient than direct combustion of fossil fuel as estimated with respect to its export at the world market prices

  12. Virginia Power's regulatory reduction program

    International Nuclear Information System (INIS)

    Miller, G.D.

    1996-01-01

    Virginia Power has two nuclear plants, North Anna and Surry Power Stations, which have two units each for a total of four nuclear units. In 1992, the Nuclear Regulatory Commission solicited comments from the nuclear industry to obtain their ideas for reducing the regulatory burden on nuclear facilities. Pursuant to the new regulatory climate, Virginia Power developed an internal program to evaluate and assess the regulatory and self-imposed requirements to which they were committed, and to pursue regulatory relief or internal changes where possible and appropriate. The criteria were that public safety must be maintained, and savings must be significant. Up to the date of the conference, over US$22 million of one-time saving had been effected, and US$2.75 million in annual savings

  13. When financiers are concerned with energy saving

    International Nuclear Information System (INIS)

    Chauveau, J.

    2005-01-01

    Innovative financial systems allow to finance investments for the energy efficiency improvement of public or residential buildings. Such solutions are implemented in Belgium and Germany. They are based on the association between a financial company, an energy supplier who makes an energy audit and the building owner who refunds the investments with the saving made on the space heating and power consumption of the building. Short paper. (J.S.)

  14. Energy saving certificates

    International Nuclear Information System (INIS)

    2005-11-01

    The French ministry of economy, finances and industry and the French agency of environment and energy mastery (Ademe) have organized on November 8, 2005, a colloquium for the presentation of the energy saving certificates, a new tool to oblige the energy suppliers to encourage their clients to make energy savings. This document gathers the transparencies presented at this colloquium about the following topics: state-of-the-art and presentation of the energy saving certificates system: presentation of the EEC system, presentation of the EEC standard operations; the energy saving certificates in Europe today: energy efficiency commitment in UK, Italian white certificate scheme, perspectives of the different European systems. (J.S.)

  15. Energy saving in refineries and petrochemical complexes

    Energy Technology Data Exchange (ETDEWEB)

    Verde, L

    1975-01-01

    Possible measures applicable in the design of refineries and petrochemical complexes, to effect energy savings were investigated. This was not limited to the single process unit problems, on the contrary the attention is mainly addressed to the identification of the interrelations between different units, emphasizing possible integrations. Particularly, the optimization of the pressure levels and number of the utility networks for steam distribution inside plant facilities, is considered, in order to maximize heat recovery in the process units, and electric power production in the central steampower generation plant. A computer program of general application, based on profitability evaluation at various fuel oil prices and different project configurations, has been developed for these purposes. The general measures applicable within certain limits are then briefly examined. The task of the process engineer is discussed in the perspective of the ''energy saving'' goal.

  16. Keys to the House: Unlocking Residential Savings With Program Models for Home Energy Upgrades

    Energy Technology Data Exchange (ETDEWEB)

    Grevatt, Jim [Energy Futures Group (United States); Hoffman, Ian [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hoffmeyer, Dale [US Department of Energy, Washington, DC (United States)

    2017-07-05

    After more than 40 years of effort, energy efficiency program administrators and associated contractors still find it challenging to penetrate the home retrofit market, especially at levels commensurate with state and federal goals for energy savings and emissions reductions. Residential retrofit programs further have not coalesced around a reliably successful model. They still vary in design, implementation and performance, and they remain among the more difficult and costly options for acquiring savings in the residential sector. If programs are to contribute fully to meeting resource and policy objectives, administrators need to understand what program elements are key to acquiring residential savings as cost effectively as possible. To that end, the U.S. Department of Energy (DOE) sponsored a comprehensive review and analysis of home energy upgrade programs with proven track records, focusing on those with robustly verified savings and constituting good examples for replication. The study team reviewed evaluations for the period 2010 to 2014 for 134 programs that are funded by customers of investor-owned utilities. All are programs that promote multi-measure retrofits or major system upgrades. We paid particular attention to useful design and implementation features, costs, and savings for nearly 30 programs with rigorous evaluations of performance. This meta-analysis describes program models and implementation strategies for (1) direct install retrofits; (2) heating, ventilating and air-conditioning (HVAC) replacement and early retirement; and (3) comprehensive, whole-home retrofits. We analyze costs and impacts of these program models, in terms of both energy savings and emissions avoided. These program models can be useful guides as states consider expanding their strategies for acquiring energy savings as a resource and for emissions reductions. We also discuss the challenges of using evaluations to create program models that can be confidently applied in

  17. Optimal sizing and control strategy of isolated grid with wind power and energy storage system

    International Nuclear Information System (INIS)

    Luo, Yi; Shi, Lin; Tu, Guangyu

    2014-01-01

    Highlights: • An energy storage sizing scheme for wind powered isolated grid is developed. • A bi-level control strategy for wind-battery isolated grid is proposed. • The energy storage type selection method for Nan’ao island grid is presented. • The sizing method and the control strategy are verified based on the Nan’ao island. • The wind-battery demonstration system has great benefit for remote areas. - Abstract: Integrating renewable energy and energy storage system provides a prospective way for power supply of remote areas. Focused on the isolated grids comprising renewable energy generation and energy storage, an energy storage sizing method for taking account of the reliability requirement and a bi-level control strategy of the isolated grids are presented in this paper. Based on comparative analysis of current energy storage characteristics and practicability, Sodium–sulfur battery is recommended for power balance control in the isolated grids. The optimal size of the energy storage system is determined by genetic algorithm and sequential simulation. The annualized cost considering the compensation cost of curtailed wind power and load is minimized when the reliability requirement can be satisfied. The sizing method emphasizes the tradeoff between energy storage size and reliability of power supply. The bi-level control strategy is designed as upper level wide area power balance control in dispatch timescale and lower level battery energy storage system V/f control in real-time range for isolated operation. The mixed timescale simulation results of Nan’ao Island grid verify the effectiveness of the proposed sizing method and control strategy

  18. The development strategies of the european electric power companies

    International Nuclear Information System (INIS)

    Heddebaud, D.

    2005-01-01

    This study takes stock on the european market of the electric power and of its development perspectives. It details the strategy and the place of the main operators and shows their forces and weaknesses. It provides a comparison of the financial performances of 28 companies (growth, margins, profitability, debt and war chest). (A.L.B.)

  19. Control Strategy Based on Wavelet Transform and Neural Network for Hybrid Power System

    Directory of Open Access Journals (Sweden)

    Y. D. Song

    2013-01-01

    Full Text Available This paper deals with an energy management of a hybrid power generation system. The proposed control strategy for the energy management is based on the combination of wavelet transform and neural network arithmetic. The hybrid system in this paper consists of an emulated wind turbine generator, PV panels, DC and AC loads, lithium ion battery, and super capacitor, which are all connected on a DC bus with unified DC voltage. The control strategy is responsible for compensating the difference between the generated power from the wind and solar generators and the demanded power by the loads. Wavelet transform decomposes the power difference into smoothed component and fast fluctuated component. In consideration of battery protection, the neural network is introduced to calculate the reference power of battery. Super capacitor (SC is controlled to regulate the DC bus voltage. The model of the hybrid system is developed in detail under Matlab/Simulink software environment.

  20. Development of methods for evaluation of electricity saving and load levelling measures. Part 2: The planning and implementation of a power conservation campaign

    Energy Technology Data Exchange (ETDEWEB)

    Storm Soerensen, M.; Madsen, P.K. [NESA A/S, Research and Development Dept. (Denmark)

    1997-12-01

    In recent years many campaigns and projects have been carried out with the purpose of reducing the energy consumption. Simultaneously a lot of economic and structural changes are taking place in society in general; changes which also affect the size of the electricity consumption. Furthermore, there is a trend towards increased use of wind mills and decentral combined heating and power plants, which affects the electricity load of the local area. It is difficult to identify and separate the effect of each of these attitude-adjusting activities. The project `Development of methods for evaluation of the effect of electricity saving and load levelling measures` focuses on two different methods which, on different levels, can be used to determine the impact of different different activities on the electricity consumption. Both methods are based on mathematical statistics, and they consist of an analysis of historical data and a test campaign which will make it possible to test specific activities in a comparatively small scale. The historical part covers the years 1974 to 1994 and include such variables as: demography, economic factors, climatic conditions, periods of electricity saving campaigns, the start of billing according to time of day tariff etc. The wish to be able to measure the extent of these energy saving and load reducing initiatives resulted in a test campaign which was carried out under very restricted conditions starting in the fall of 1996. If the effect of the test campaign can be measured and as a consequence of this a method can be estimated, it will be possible to place models which can measure the effect of future campaigns. The primary object of the campaign is not the size of the electricity savings of the individual customer, but rather to obtain total savings for the entire group of customers. The test has been structured in a way which makes it possible to perform an analysis of the effect of the campaign by use of analysis of intervention

  1. Cost savings from extended life nuclear plants

    International Nuclear Information System (INIS)

    Forest, L.R. Jr.; Deutsch, T.R.; Schenler, W.W.

    1988-09-01

    This study assesses the costs and benefits of nuclear power plant life extension (NUPLEX) for the overall US under widely varying economic assumptions and compares these with alternative new coal- fired plants (NEWCOAL). It is found that NUPLEX saves future electricity consumers more than 3 cents/-kwh compared with NEWCOAL. The NUPLEX costs and benefits for existing individual US nuclear power plants under base-line, or most likely, assumptions are assessed to determine the effects of the basic plant design and plant age. While benefits vary widely, virtually all units would have a positive benefit from NUPLEX. The study also presents a cost-benefit analysis of the nuclear industry's planned advanced light water reactor (ALWR). It is concluded that ALWR offers electrical power at a substantially lower cost than NEWCOAL. 9 refs., 6 figs

  2. A Low-Power and Low-Voltage Power Management Strategy for On-Chip Micro Solar Cells

    Directory of Open Access Journals (Sweden)

    Ismail Cevik

    2015-01-01

    Full Text Available Fundamental characteristics of on-chip micro solar cell (MSC structures were investigated in this study. Several MSC structures using different layers in three different CMOS processes were designed and fabricated. Effects of PN junction structure and process technology on solar cell performance were measured. Parameters for low-power and low-voltage implementation of power management strategy and boost converter based circuits utilizing fractional voltage maximum power point tracking (FVMPPT algorithm were determined. The FVMPPT algorithm works based on the fraction between the maximum power point operation voltage and the open circuit voltage of the solar cell structure. This ratio is typically between 0.72 and 0.78 for commercially available poly crystalline silicon solar cells that produce several watts of power under typical daylight illumination. Measurements showed that the fractional voltage ratio is much higher and fairly constant between 0.82 and 0.85 for on-chip mono crystalline silicon micro solar cell structures that produce micro watts of power. Mono crystalline silicon solar cell structures were observed to result in better power fill factor (PFF that is higher than 74% indicating a higher energy harvesting efficiency.

  3. Bidding strategies for virtual power plants considering CHPs and intermittent renewables

    International Nuclear Information System (INIS)

    Zapata Riveros, J.; Bruninx, K.; Poncelet, K.; D’haeseleer, W.

    2015-01-01

    Highlights: • A stochastic optimization evaluates the optimal bidding strategy of a VPP. • Three different strategies were assessed: ‘static’, ‘flexible DA’ and ‘flexible RT’. • The ‘flexible RT’ attains the largest profits. It adapts the VPP output in real-time. - Abstract: Energy efficiency and renewable-energy sources (RES) are fundamental parts of the European energy policy. For this reason, efficient distributed generation technologies such as combined heat and power coupled to district heating (CHP–DH) and RES based electricity are largely promoted. Additionally, the flexibility that CHP–DH offers to the power system is seen as an option to balance the intermittent output of RES-based generation. This could be done by aggregating RES based electricity generation and CHP DH in a virtual power plant (VPP). In this framework, the present work presents a methodology to evaluate the optimal bidding strategy of a VPP composed of a CHP–DH and RES based generators. The objective is to investigate the optimal bidding strategy for a VPP that uses CHP DH to compensate for the uncertainties regarding RES-based electricity generation and market prices. The VPP operator nominates its energy to the day ahead market the day before the actual delivery (D-1). In real time, any deviation from the day-ahead schedule is settled in the imbalance market. The uncertainties are modeled using a two stage stochastic programming approach. Three different bidding strategies are studied: ‘static’, ‘flexible DA’ and ‘flexible RT’. The major difference between the studied strategies lies in the dispatch decisions. The ‘static’ strategy does not adjust the scheduled output of the CHP. Whereas, the ‘flexible DA’ and ‘flexible RT’ strategies differ from each other in terms of the information available at the moment of performing the reschedule (second stage decision). The ‘flexible DA’ reschedules the CHP output for the whole day assuming

  4. Advanced maintenance strategies for power plant operators - introducing inter-plant life cycle management. ZES research focus 'condition-based maintenance in power engineering'

    International Nuclear Information System (INIS)

    Graeber, U.

    2003-01-01

    The optimisation of maintenance activities observed in recent years can be attributed above all to the use and continuing development of testing and diagnostic techniques, to the increased level of system and component automation and to more efficient work organisation. Despite the considerable success of these efforts, the potential for further cost reductions is still far from exhausted. The risks connected to reliability, availability and safety need to be analysed in greater detail in order to ensure the sustainability of the savings already achieved as well as those yet to be realised. The systematic application of condition-based maintenance and the introduction of structured life cycle management are essential prerequisites. Within the framework of its ''Condition-Based Maintenance in Power Engineering'' research focus, the Energy Research Centre (ZES) has set up a specialist network in which experts from various institutes belonging to the Faculty of Mechanical Engineering and the Faculty of Informatic, Electrical Engineering and Information Technology can develop interdisciplinary solutions for advanced maintenance strategies. The ZES offers the industry a platform for cooperating on current issues relating to the supply of energy and supports the movement towards sustainable improvements to competitiveness through research and consulting activities. It applies professional project and quality management procedures to ensure that contracts covering interdisciplinary topics and projects are handled in a coherent manner. (orig.)

  5. Autonomous Active and Reactive Power Distribution Strategy in Islanded Microgrids

    DEFF Research Database (Denmark)

    Wu, Dan; Tang, Fen; Guerrero, Josep M.

    2014-01-01

    This paper proposes an autonomous active and reactive power distribution strategy that can be applied directly on current control mode (CCM) inverters, being compatible as well with conventional droop-controlled voltage control mode (VCM) converters. In a microgrid, since renewable energy sources...

  6. Water Savings of Crop Redistribution in the United States

    Directory of Open Access Journals (Sweden)

    Kyle Frankel Davis

    2017-01-01

    Full Text Available Demographic growth, changes in diet, and reliance on first-generation biofuels are increasing the human demand for agricultural products, thereby enhancing the human pressure on global freshwater resources. Recent research on the food-water nexus has highlighted how some major agricultural regions of the world lack the water resources required to sustain current growth trends in crop production. To meet the increasing need for agricultural commodities with limited water resources, the water use efficiency of the agricultural sector must be improved. In this regard, recent work indicates that the often overlooked strategy of changing the crop distribution within presently cultivated areas offers promise. Here we investigate the extent to which water in the United States could be saved while improving yields simply by replacing the existing crops with more suitable ones. We propose crop replacement criteria that achieve this goal while preserving crop diversity, economic value, nitrogen fixation, and food protein production. We find that in the United States, these criteria would greatly improve calorie (+46% and protein (+34% production and economic value (+208%, with 5% water savings with respect to the present crop distribution. Interestingly, greater water savings could be achieved in water-stressed agricultural regions of the US such as California (56% water savings, and other western states.

  7. REMINDER Saved Leave Scheme (SLS) : Transfer of leave to saved leave accounts

    CERN Multimedia

    HR Division

    2002-01-01

    Under the provisions of the voluntary saved leave scheme (SLS), a maximum total of 10 days'*) annual and compensatory leave (excluding saved leave accumulated in accordance with the provisions of Administrative Circular No. 22B) can be transferred to the saved leave account at the end of the leave year (30 September). We remind you that, since last year, unused leave of all those taking part in the saved leave scheme at the closure of the leave-year accounts is transferred automatically to the saved leave account on that date. Therefore, staff members have no administrative steps to take. In addition, the transfer, which eliminates the risk of omitting to request leave transfers and rules out calculation errors in transfer requests, will be clearly shown in the list of leave transactions that can be consulted in EDH from October 2002 onwards. Furthermore, this automatic leave transfer optimizes staff members' chances of benefiting from a saved leave bonus provided that they are still participants in the schem...

  8. A general solution strategy of modified power method for higher mode solutions

    International Nuclear Information System (INIS)

    Zhang, Peng; Lee, Hyunsuk; Lee, Deokjung

    2016-01-01

    A general solution strategy of the modified power iteration method for calculating higher eigenmodes has been developed and applied in continuous energy Monte Carlo simulation. The new approach adopts four features: 1) the eigen decomposition of transfer matrix, 2) weight cancellation for higher modes, 3) population control with higher mode weights, and 4) stabilization technique of statistical fluctuations using multi-cycle accumulations. The numerical tests of neutron transport eigenvalue problems successfully demonstrate that the new strategy can significantly accelerate the fission source convergence with stable convergence behavior while obtaining multiple higher eigenmodes at the same time. The advantages of the new strategy can be summarized as 1) the replacement of the cumbersome solution step of high order polynomial equations required by Booth's original method with the simple matrix eigen decomposition, 2) faster fission source convergence in inactive cycles, 3) more stable behaviors in both inactive and active cycles, and 4) smaller variances in active cycles. Advantages 3 and 4 can be attributed to the lower sensitivity of the new strategy to statistical fluctuations due to the multi-cycle accumulations. The application of the modified power method to continuous energy Monte Carlo simulation and the higher eigenmodes up to 4th order are reported for the first time in this paper. -- Graphical abstract: -- Highlights: •Modified power method is applied to continuous energy Monte Carlo simulation. •Transfer matrix is introduced to generalize the modified power method. •All mode based population control is applied to get the higher eigenmodes. •Statistic fluctuation can be greatly reduced using accumulated tally results. •Fission source convergence is accelerated with higher mode solutions.

  9. Assessment of Soft Power Strategies: Towards an Aggregative Analytical Model for Country-Focused Case Study Research

    Directory of Open Access Journals (Sweden)

    Patalakh Artem

    2016-10-01

    Full Text Available The paper advances a realist analytical model for case studies of national soft power policies. First, it argues that for the purposes of realist analysis, a soft power policy must be considered as a rational strategy pursued under the conditions of competition. Furthermore, it emphasises the importance of taking into account the specificities of the recipient state as well as the fact that a soft power strategy is targeted at both its elite and its public. In addition, the article substantiates the necessity to draw a clear-cut distinction between soft power sources and instruments and shows possible shortcomings that research can have should this distinction fail to be made. Finally, the paper discusses the impact of a competitor’s presence on a soft power strategy and specifies the terms under which disregarding this impact may engender a wrong conclusion.

  10. Chapter 17: Residential Behavior Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Stewart, James [Cadmus, Waltham, MA (United States); Todd, Annika [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-11-01

    Residential behavior-based (BB) programs use strategies grounded in the behavioral and social sciences to influence household energy use. These may include providing households with real-time or delayed feedback about their energy use; supplying energy efficiency education and tips; rewarding households for reducing their energy use; comparing households to their peers; and establishing games, tournaments, and competitions. BB programs often target multiple energy end uses and encourage energy savings, demand savings, or both. Savings from BB programs are usually a small percentage of energy use, typically less than 5 percent. Utilities will continue to implement residential BB programs as large-scale, randomized control trials (RCTs); however, some are now experimenting with alternative program designs that are smaller scale; involve new communication channels such as the web, social media, and text messaging; or that employ novel strategies for encouraging behavior change (for example, Facebook competitions). These programs will create new evaluation challenges and may require different evaluation methods than those currently employed to verify any savings they generate. Quasi-experimental methods, however, require stronger assumptions to yield valid savings estimates and may not measure savings with the same degree of validity and accuracy as randomized experiments.

  11. Community Savings Groups, Financial Security, and HIV Risk Among Female Sex Workers in Iringa, Tanzania.

    Science.gov (United States)

    Mantsios, Andrea; Galai, Noya; Mbwambo, Jessie; Likindikoki, Samuel; Shembilu, Catherine; Mwampashi, Ard; Beckham, S W; Leddy, Anna; Davis, Wendy; Sherman, Susan; Kennedy, Caitlin; Kerrigan, Deanna

    2018-02-24

    This study assessed the association between community savings group participation and consistent condom use (CCU) among female sex workers (FSW) in Iringa, Tanzania. Using cross-sectional data from a survey of venue-based FSW (n = 496), logistic regression was used to examine the associations between financial indicators including community savings group participation and CCU. Over one-third (35%) of the women participated in a savings group. Multivariable regression results indicated that participating in a savings group was significantly associated with nearly two times greater odds of CCU with new clients in the last 30 days (aOR = 1.77, 95% CI 1.10-2.86). Exploratory mediation analysis indicated that the relationship between savings group participation and CCU was partially mediated by financial security, as measured by monthly income. Findings indicate that community savings groups may play an important role in reducing sexual risk behaviors of FSW and hold promise as part of comprehensive, community-led HIV prevention strategies among FSW.

  12. Evaluation of Savings in Energy-Efficient Public Housing in the Pacific Northwest

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-10-01

    This report presents the results of an energy performance and cost-effectiveness analysis. The Salishan phase 7 and demonstration homes were compared to Salishan phase 6 homes built to 2006 Washington State Energy Code specifications 2. Predicted annual energy savings (over Salishan phase 6) was 19% for Salishan phase 7, and between 19-24% for the demonstration homes (depending on ventilation strategy). Approximately two-thirds of the savings are attributable to the DHP. Working with the electric utility provider, Tacoma Public Utilities, researchers conducted a billing analysis for Salishan phase 7. Median energy use for the development is 11,000 kWh; annual energy costs are $780, with a fair amount of variation dependent on size of home. Preliminary analysis of savings between Salishan 7 and previous phases (4 through 6) suggest savings of between 20 and 30 percent. A more comprehensive comparison between Salishan 7 and previous phases will take place in year two of this project.

  13. Swords into ploughshares? China's Soft Power strategy in Southeast Asia and its challenges1

    Directory of Open Access Journals (Sweden)

    Tony Tai-Ting Liu

    2014-01-01

    Full Text Available Since the 1990s, alongside China's economic growth, the international community has fostered a general anxiety towards a "China threat." In order to relieve itself from suspicion, China adopted the dual strategies of "harmonious worldview" and "good neighbor policy." The strategies led to the use of soft power in China's foreign policy. China aimed to reduce security concerns implied by the threat theory by supporting an image that caters to international peace and development. This article seeks to explain how China achieves its interests in Southeast Asia through the use of soft power. The authors address the concepts of "harmonious worldview" and "good neighbor policy" and how the twin strategies and soft power have shaped China's foreign policy in recent years. This article aims to provide insights into China's policy options in Southeast Asia in the near future.

  14. Economic and Environmental Impact of Energy Saving in Healthcare Buildings

    Directory of Open Access Journals (Sweden)

    Justo García-Sanz-Calcedo

    2018-03-01

    Full Text Available The purpose of this article is to estimate the economic and environmental impacts of energy consumption derived from healthcare buildings and proposes several energy-saving options in the sector. An experimental energy consumption study was development between 2005 and 2013 in 12 hospitals and 70 healthcare centres in Spain, built between 1980 and 2005 through audits carried out between 2005 and 2012, performed by the Extremadura Energy Agency. The study focused on electric energy, HVAC, DWH, lighting systems, renewable energies, maintenance strategy, thermal insulation, and optimal building size. Specifically, the following parameters were evaluated: energy savings, investment emission of CO2, NO2, and SO2 gases, and payback. The results revealed that through an appropriate energy management of healthcare buildings it is possible to save up to 8.60 kWh/m2 per year, for buildings of less than 5000 m2 (with no beds, which represents an expense of 1.55 €/m2. In healthcare buildings larger than 5000 m2 (with beds, it was possible to save up to 6.88 kWh/m2 per year, which represents an expense of 1.25 €/m2.

  15. Holiday homes - electric power savings; Sommerhuse - elbesparelser her og nu

    Energy Technology Data Exchange (ETDEWEB)

    Kofoed Esbensen, N -U; Roed Rasmussen, E [Esbensen Raadgivende Ingenioerer A/S, Copenhagen (Denmark); Weldingh, P [Lokalenergi, Viby J. (Denmark); Worm, J; Adams Rasmussen, L [Energitjenesten, Aarhus (Denmark); Reuss, M [Elsparefonden, Copenhagen (Denmark); Ellehauge, K; Kjaergaard, C -J [Ellehauge og Kildemoes, Aarhus (Denmark); Jensen, Ole Michael [Aalborg Univ. SBi, Aalborg (Denmark)

    2010-09-15

    A questionnaire survey among 700 holiday home owners was conducted and followed up by interviews with representatives of typical groups of holiday home owners and a number of key persons representing rental, building, electricity supply, regulatory processing and supply of renewable energy facilities to holiday homes. The results of the questionnaire survey and of former surveys on technical savings potential are included in an easy-to-read catalogue of ideas with directions and recommendations for various groups of holiday home users and players. The recommendations are grouped into eight topics of more or less relevance for the various target groups. (LN)

  16. Measuring industrial energy savings

    International Nuclear Information System (INIS)

    Kelly Kissock, J.; Eger, Carl

    2008-01-01

    Accurate measurement of energy savings from industrial energy efficiency projects can reduce uncertainty about the efficacy of the projects, guide the selection of future projects, improve future estimates of expected savings, promote financing of energy efficiency projects through shared-savings agreements, and improve utilization of capital resources. Many efforts to measure industrial energy savings, or simply track progress toward efficiency goals, have had difficulty incorporating changing weather and production, which are frequently major drivers of plant energy use. This paper presents a general method for measuring plant-wide industrial energy savings that takes into account changing weather and production between the pre and post-retrofit periods. In addition, the method can disaggregate savings into components, which provides additional resolution for understanding the effectiveness of individual projects when several projects are implemented together. The method uses multivariable piece-wise regression models to characterize baseline energy use, and disaggregates savings by taking the total derivative of the energy use equation. Although the method incorporates search techniques, multi-variable least-squares regression and calculus, it is easily implemented using data analysis software, and can use readily available temperature, production and utility billing data. This is important, since more complicated methods may be too complex for widespread use. The method is demonstrated using case studies of actual energy assessments. The case studies demonstrate the importance of adjusting for weather and production between the pre- and post-retrofit periods, how plant-wide savings can be disaggregated to evaluate the effectiveness of individual retrofits, how the method can identify the time-dependence of savings, and limitations of engineering models when used to estimate future savings

  17. Different regulatory strategies in regulation of nuclear power projects: An Indian experience

    International Nuclear Information System (INIS)

    Khan, Sohail Ahmad

    2002-01-01

    Regulatory strategy needed for management of safety and safety culture involves careful planning and use of engineering concepts keeping in mind feasibility to implement certain safety requirements. It also requires adequate attention on working environment and mental conditions of designers, operating and maintenance staff and regulators. Different strategies followed during safety review and regulatory inspection of nuclear power projects for improving status of safety management and safety cultures have given certain results. The present paper brings out certain experience gained during regulation of Indian Nuclear Power Projects by Atomic Energy Regulatory Board of India in the area of management of safety and safety culture. (author)

  18. Electric power saving potential due to domestic refrigerators replacement; Potencial de ahorro de energia electrica por el reemplazo de refrigeradores domesticos

    Energy Technology Data Exchange (ETDEWEB)

    Peralta Solorio, Jose Luis [Fideicomiso para el Ahorro de Energia Electrica (Mexico)]. E-mail: jose.peralta@cfe.gob.mx

    2006-04-15

    In Mexico the second most used electrical appliance is: refrigerator. Owing to its use, it would be a promising option for electric power saving. In Guadalajara, Reynosa and Tampico it was performed a study with the aim of launching a project to replace the old refrigerators with new ones which are more effective and less expensive. Since the refrigerators cost and the electrical invoicing saving, the electric appliance change is profitable. To expect with this replacement more than eight million of refrigerators manufactured before 1997 will be changed. [Spanish] El refrigerador es el segundo electrodomestico mas utilizado a nivel nacional, esto permite que debido a su uso sea una opcion prometedora para el ahorro de energia electrica. Se hizo un estudio en Guadalajara, Reynosa y Tampico con el fin de lanzar un proyecto para sustituir los refrigeradores viejos por unos nuevos que sean mas eficaces y menos costosos. Por el costo de los refrigeradores y el ahorro en la facturacion electrica, el cambio de electrodomestico es rentable, de esta manera se espera que los mas de ocho millones de refrigeradores fabricados antes de 1997 que existen en el pais sean cambiados.

  19. Airline enters 2 shared-savings deals for $1M

    Energy Technology Data Exchange (ETDEWEB)

    Barber, J.

    1984-02-06

    Pan American World Airways has two shared-savings agreements to reduce electricity costs at its maintenance base near Miami International Airport by 20 to 25%. The two Andover 256 energy management systems (EMS) to monitor and control lighting and cooling in four buildings are already in operation. A second phase involving solar-powered water heating systems and retrofit work to air conditioning, ventilating, and lighting systems at six other buildings is nearing completion. Pan Am will divide the projected $700,000 in annual energy savings with two investor groups for seven years, after which Pan Am can buy the equipment at fair market value, renew the contract, or have the equipment removed.

  20. 76 FR 16477 - General Reporting and Recordkeeping by Savings Associations and Savings and Loan Holding Companies

    Science.gov (United States)

    2011-03-23

    ... Savings Associations and Savings and Loan Holding Companies AGENCY: Office of Thrift Supervision (OTS...), 12 CFR 562.4 (audit of savings association, savings and loan holding company, or affiliate), 12 CFR... the savings association), 12 CFR 584.1(f) (books and records of each savings and loan holding company...

  1. Strategies for energy saving in buildings by means of automatic control; Estrategias de ahorro de energia en inmuebles mediante el control automatico

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Trujillo, Oscar [Johnson Controls de Mexico S. A. de C. V., Mexico, D. F. (Mexico)

    1998-12-31

    In this paper some of the measures and strategies for energy saving that can be applied in different types of buildings, mainly in hotels and office buildings, are presented. The proposed actions are accomplished with the aid of the automatic control equipment and the operation and/or maintenance personnel that supervises and establishes the control parameters of each one of the strategies than are focused to the appropriate utilization of the electric energy. [Espanol] En este documento se presentan algunas de las medidas y estrategias de ahorro de energia que pueden ser aplicadas en diferentes tipos de inmuebles, principalmente en hoteles y en edificios de oficinas. Las acciones propuestas son realizadas con la ayuda del equipo de control automatico y del personal de operacion y/o mantenimiento quien supervisa y establece los parametros de control de cada una de las estrategias que son destinadas a la buena utilizacion de la energia electrica.

  2. Strategies for energy saving in buildings by means of automatic control; Estrategias de ahorro de energia en inmuebles mediante el control automatico

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Trujillo, Oscar [Johnson Controls de Mexico S. A. de C. V., Mexico, D. F. (Mexico)

    1999-12-31

    In this paper some of the measures and strategies for energy saving that can be applied in different types of buildings, mainly in hotels and office buildings, are presented. The proposed actions are accomplished with the aid of the automatic control equipment and the operation and/or maintenance personnel that supervises and establishes the control parameters of each one of the strategies than are focused to the appropriate utilization of the electric energy. [Espanol] En este documento se presentan algunas de las medidas y estrategias de ahorro de energia que pueden ser aplicadas en diferentes tipos de inmuebles, principalmente en hoteles y en edificios de oficinas. Las acciones propuestas son realizadas con la ayuda del equipo de control automatico y del personal de operacion y/o mantenimiento quien supervisa y establece los parametros de control de cada una de las estrategias que son destinadas a la buena utilizacion de la energia electrica.

  3. Listening to the vocal citizens: how do politically active individuals choose between life saving programs?

    Energy Technology Data Exchange (ETDEWEB)

    Ramsberg, J. [Stockholm School of Economics, Stockholm (Sweden)

    1998-07-01

    Large disparities in the cost per life saved for different life saving interventions have been reported in many studies. According to some researchers, these differences reflect the public's preoccupation with selected qualitative aspects of risk. However, it is not obvious that these disparities reflect public preferences. In studies of the variation in cost per life saved the public accept, most respondents are willing to trade qualitative characteristics for lives saved, but there is a small but significant group of respondents who will not make the tradeoff, i.e. assign infinite value to one or more of the qualitative factors. It has been suggested that this group could be particularly vocal, which might account for the large variation in cost per life saved. In the first attempt to address this issue, a survey of people living under a power line in Stockholm was undertaken. This population was chosen because the local government had decided to remove the power line after being pressured by the citizens and on interest group. Tests of how more politically active individuals differ from less active were undertaken. Most importantly, it was found that more politically active respondents were less likely to trade qualitative characteristics for lives saved, but only for the risk in which they were active and only up to a point. There still was a group of respondents who were unwilling to make the tradeoff. (author)

  4. A decentralized charging control strategy for plug-in electric vehicles to mitigate wind farm intermittency and enhance frequency regulation

    Science.gov (United States)

    Luo, Xiao; Xia, Shiwei; Chan, Ka Wing

    2014-02-01

    This paper proposes a decentralized charging control strategy for a large population of plug-in electric vehicles (PEVs) to neutralize wind power fluctuations so as to improve the regulation of system frequency. Without relying on a central control entity, each PEV autonomously adjusts its charging or discharging power in response to a communal virtual price signal and based on its own urgency level of charging. Simulation results show that under the proposed charging control, the aggregate PEV power can effectively neutralize wind power fluctuations in real-time while differential allocation of neutralization duties among the PEVs can be realized to meet the PEV users' charging requirements. Also, harmful wind-induced cyclic operations in thermal units can be mitigated. As shown in economic analysis, the proposed strategy can create cost saving opportunities for both PEV users and utility.

  5. Maintenance cost savings - snubber elimination with limit stops

    International Nuclear Information System (INIS)

    Monette, P.; Baltus, R.; Cloud, R.L.

    1995-01-01

    ''Active'' snubbers can be replaced with ''passive'' Limit Stops using two separate strategies. One is a straightforward piping re-analysis to optimize the number of dynamics supports and replace remaining snubbers with Limit Stops. A second approach is to take implicit advantage of the margins afforded by the ASME Code Case N-411 damping ratios and simply replace snubbers one-for-one with no re-analysis. Both methods result in major maintenance cost savings and both have been received favorably by the USNRC (United States Nuclear Regulatory Commission). Approaches to maintenance cost reduction using these strategies are discussed in this paper. (Author). 11 refs., 4 figs

  6. Advertising energy saving programs: The potential environmental cost of emphasizing monetary savings.

    Science.gov (United States)

    Schwartz, Daniel; Bruine de Bruin, Wändi; Fischhoff, Baruch; Lave, Lester

    2015-06-01

    Many consumers have monetary or environmental motivations for saving energy. Indeed, saving energy produces both monetary benefits, by reducing energy bills, and environmental benefits, by reducing carbon footprints. We examined how consumers' willingness and reasons to enroll in energy-savings programs are affected by whether advertisements emphasize monetary benefits, environmental benefits, or both. From a normative perspective, having 2 noteworthy kinds of benefit should not decrease a program's attractiveness. In contrast, psychological research suggests that adding external incentives to an intrinsically motivating task may backfire. To date, however, it remains unclear whether this is the case when both extrinsic and intrinsic motivations are inherent to the task, as with energy savings, and whether removing explicit mention of extrinsic motivation will reduce its importance. We found that emphasizing a program's monetary benefits reduced participants' willingness to enroll. In addition, participants' explanations about enrollment revealed less attention to environmental concerns when programs emphasized monetary savings, even when environmental savings were also emphasized. We found equal attention to monetary motivations in all conditions, revealing an asymmetric attention to monetary and environmental motives. These results also provide practical guidance regarding the positioning of energy-saving programs: emphasize intrinsic benefits; the extrinsic ones may speak for themselves. (c) 2015 APA, all rights reserved).

  7. ONCE AGAIN ABOUT DETERMINATION OF SAVING OF ENERGY FOR TRACTION DUE TO PARTIAL CUT–OFF OF TRACTION ENGINES OF ELECTRIC ROLLING STOCK

    Directory of Open Access Journals (Sweden)

    G. K. Getman

    2013-09-01

    Full Text Available Purpose. In general the well known methods for determination of energy saving due to the partial traction engines cut-off based on their comparison to efficiency coefficient or to the power of energy losses do not allow objective estimation of efficiency of these measures and in a number of cases result in erroneous results and errors. The search for new more advanced methods for determination of energy saving at the partial cut-off of the traction engines is needed. Methodology. The method of calculation determination of energy saving when partial cutting-off of the traction engines is offered. It is based on the use of rationality coefficient as the loading mode of the electric power consumption for the measuring instrument of transportation activity. Findings. Using the given mathematical expressions it is possible to determine the energy saving in both the relative and absolute values and set the terms (motion speed and route gradient, under which the energy saving will take place. Originality. The method of the task solving, which is based on the evaluation of energy consumption differences for the compared variants (not on the comparison of efficiency coefficient or differences of power of energy losses is offered. Practical value. The given methodology allows obtaining more exact conclusions in relation to the electric power consumption, as the comparison of energy losses power or the efficiency coefficient does not determine precisely the electric power consumption for traction. Therefore the conclusions based on the comparison of power of energy losses or efficiency coefficient can appear inexact.

  8. Energy savings assessment for digital-to-analog converter boxes

    International Nuclear Information System (INIS)

    Cheung, Hoi Ying; Meier, Alan; Brown, Richard

    2011-01-01

    The Digital Television (DTV) Converter Box Coupon Program was administered by the U.S. government to subsidize purchases of digital-to-analog converter boxes, with up to two $40 coupons for each eligible household. In order to qualify as Coupon Eligible Converter Boxes (CECBs), these devices had to meet a number of minimum performance specifications, including energy efficiency standards. The Energy Star Program also established voluntary energy efficiency specifications that are more stringent than the CECB requirements. In this study, we measured the power and energy consumptions for a sample of 12 CECBs (including 6 Energy Star labeled models) in-use in homes and estimated aggregate energy savings produced by the energy efficiency policies. Based on the 35 million coupons redeemed through the end of the program, our analysis indicates that between 2500 and 3700 GWh per year are saved as a result of the energy efficiency policies implemented on digital-to-analog converter boxes. The energy savings generated are equivalent to the annual electricity use of 280,000 average US homes. - Research highlights: → We examined energy efficiency policies on digital-to-analog converter boxes in US. → The government assistance program resulted in high participation. → 35 million coupons were redeemed for the purchases of energy efficient DTAs. → Between 2500 and 3700 GWh per year are saved as a result of the policies. → Savings are equivalent to the annual electricity use of 280,000 average US homes.

  9. Evaluation of Savings in Energy-Efficient Public Housing in the Pacific Northwest

    Energy Technology Data Exchange (ETDEWEB)

    Gordon, A. [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States); Lubliner, M. [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States); Howard, L. [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States); Kunkle, R. [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States)

    2013-10-01

    This report presents the results of an energy performance and cost-effectiveness analysis. The Salishan phase 7 and demonstration homes were compared to Salishan phase 6 homes built to 2006 Washington State Energy Code specifications 2. Predicted annual energy savings (over Salishan phase 6) was 19% for Salishan phase 7, and between 19-24% for the demonstration homes (depending on ventilation strategy). Approximately two-thirds of the savings are attributable to the DHP. Working with the electric utility provider, Tacoma Public Utilities, researchers conducted a billing analysis for Salishan phase 7.

  10. Optimal Bidding Strategies for Wind Power Producers in the Day-ahead Electricity Market

    Directory of Open Access Journals (Sweden)

    Xiaolin Liu

    2012-11-01

    Full Text Available Wind Power Producers (WPPs seek to maximize profit and minimize the imbalance costs when bidding into the day-ahead market, but uncertainties in the hourly available wind and forecasting errors make the bidding risky. This paper assumes that hourly wind power output given by the forecast follows a normal distribution, and proposes three different bidding strategies, i.e., the expected profit-maximization strategy (EPS, the chance-constrained programming-based strategy (CPS and the multi-objective bidding strategy (ECPS. Analytical solutions under the three strategies are obtained. Comparisons among the three strategies are conducted on a hypothetical wind farm which follows the Spanish market rules. Results show that bid under the EPS is highly dependent on market clearing price, imbalance prices, and also the mean value and standard deviation of wind forecast, and that bid under the CPS is largely driven by risk parameters and the mean value and standard deviation of the wind forecast. The ECPS combining both EPS and CPS tends to choose a compromise bid. Furthermore, the ECPS can effectively control the tradeoff between expected profit and target profit for WPPs operating in volatile electricity markets.

  11. Voltage Control of Distribution Grids with Multi-Microgrids Using Reactive Power Management

    Directory of Open Access Journals (Sweden)

    WLODARCZYK, P.

    2015-02-01

    Full Text Available Low-voltage Microgrids can be valuable sources of ancillary services for the Distribution System Operators (DSOs. The aim of this paper was to study if and how multi-microgrids can contribute to Voltage Control (VC in medium-voltage distribution grids by means of reactive power generation and/or absorption. The hierarchical control strategy was proposed with the main focus on the tertiary control which was defined as optimal power flow problem. The interior-point algorithm was applied to optimise experimental benchmark grid with the presence of Distributed Energy Resources (DERs. Moreover, two primary objectives were formulated: active power losses and amount of reactive power used to reach the voltage profile. As a result the active power losses were minimised to the high extent achieving the savings around 22% during entire day.

  12. Research on multi-level decision game strategy of electricity sales market considering ETS and block chain

    Science.gov (United States)

    Liu, Jinjie

    2017-08-01

    In order to fully consider the impact of future policies and technologies on the electricity sales market, improve the efficiency of electricity market operation, realize the dual goal of power reform and energy saving and emission reduction, this paper uses multi-level decision theory to put forward the double-layer game model under the consideration of ETS and block chain. We set the maximization of electricity sales profit as upper level objective and establish a game strategy model of electricity purchase; while we set maximization of user satisfaction as lower level objective and build a choice behavior model based on customer satisfaction. This paper applies the strategy to the simulation of a sales company's transaction, and makes a horizontal comparison of the same industry competitors as well as a longitudinal comparison of game strategies considering different factors. The results show that Double-layer game model is reasonable and effective, it can significantly improve the efficiency of the electricity sales companies and user satisfaction, while promoting new energy consumption and achieving energy-saving emission reduction.

  13. Analyzing Vehicle Fuel Saving Opportunities through Intelligent Driver Feedback

    Energy Technology Data Exchange (ETDEWEB)

    Gonder, J.; Earleywine, M.; Sparks, W.

    2012-06-01

    Driving style changes, e.g., improving driver efficiency and motivating driver behavior changes, could deliver significant petroleum savings. This project examines eliminating stop-and-go driving and unnecessary idling, and also adjusting acceleration rates and cruising speeds to ideal levels to quantify fuel savings. Such extreme adjustments can result in dramatic fuel savings of over 30%, but would in reality only be achievable through automated control of vehicles and traffic flow. In real-world driving, efficient driving behaviors could reduce fuel use by 20% on aggressively driven cycles and by 5-10% on more moderately driven trips. A literature survey was conducted of driver behavior influences, and pertinent factors from on-road experiments with different driving styles were observed. This effort highlighted important driver influences such as surrounding vehicle behavior, anxiety over trying to get somewhere quickly, and the power/torque available from the vehicle. Existing feedback approaches often deliver efficiency information and instruction. Three recommendations for maximizing fuel savings from potential drive cycle improvement are: (1) leveraging applications with enhanced incentives, (2) using an approach that is easy and widely deployable to motivate drivers, and (3) utilizing connected vehicle and automation technologies to achieve large and widespread efficiency improvements.

  14. Application of MSHIM core control strategy for westinghouse AP1000 nuclear power plant

    International Nuclear Information System (INIS)

    Onoue, Masaaki; Kawanishi, Tomohiro; Carlson, William R.; Morita, Toshio

    2003-01-01

    Westinghouse has developed a new core control strategy, in which two independently moving Rod Cluster Control Assembly (RCCA) groups are utilized for core control; one group for reactivity/temperature control, the other for axial power distribution (Axial Offset) control. This control procedure eliminates the need for Chemical Shim adjustments during power maneuvers, such as load follow, and is designated MSHIM (Mechanical Shim). This core control strategy is utilized in the AP1000. In the AP1000, it is possible to perform MSHIM load follow maneuvers for up to 95% of cycle life without changing the soluble boron concentration in the moderator. This core control strategy has been evaluated, via computer simulations, to provide appropriate margins to core and fuel design limits during normal operation maneuvers (including load follow operations) and also during anticipated Condition II accident transients. The primary benefits of MSHIM as a control strategy are as follows; Power change operation can be totally automated due to the elimination of boron concentration adjustments. Full load follow capability is achievable for up to more than 95% of cycle life. Load follow operations performed solely by mechanical devices results in a significant reduction in the boron system requirements and a significant reduction in daily effluent to be processed. (author)

  15. Evaluating system reliability and targeted hardening strategies of power distribution systems subjected to hurricanes

    International Nuclear Information System (INIS)

    Salman, Abdullahi M.; Li, Yue; Stewart, Mark G.

    2015-01-01

    Over the years, power distribution systems have been vulnerable to extensive damage from hurricanes which can cause power outage resulting in millions of dollars of economic losses and restoration costs. Most of the outage is as a result of failure of distribution support structures. Over the years, various methods of strengthening distribution systems have been proposed and studied. Some of these methods, such as undergrounding of the system, have been shown to be unjustified from an economic point of view. A potential cost-effective strategy is targeted hardening of the system. This, however, requires a method of determining critical parts of a system that when strengthened, will have greater impact on reliability. This paper presents a framework for studying the effectiveness of targeted hardening strategies on power distribution systems subjected to hurricanes. The framework includes a methodology for evaluating system reliability that relates failure of poles and power delivery, determination of critical parts of a system, hurricane hazard analysis, and consideration of decay of distribution poles. The framework also incorporates cost analysis that considers economic losses due to power outage. A notional power distribution system is used to demonstrate the framework by evaluating and comparing the effectiveness of three hardening measures. - Highlight: • Risk assessment of power distribution systems subjected to hurricanes is carried out. • Framework for studying effectiveness of targeted hardening strategies is presented. • A system reliability method is proposed. • Targeted hardening is cost effective for existing systems. • Economic losses due to power outage should be considered for cost analysis.

  16. Emissions trading and firms' strategies. The case of power producers

    International Nuclear Information System (INIS)

    Rousse, O.

    2005-11-01

    This thesis deals with the impacts of a domestic emissions trading scheme on firms' strategies. As recent experiences of such programs (Acid Rain Program, RECLAIM Program, NOx Budget Program and the European Union Emissions Trading Scheme) concern mainly heat and power producers, we analyze especially strategies of these companies. In context of electricity market deregulation, our study takes two directions: uncertainty and competitive distortions. Concerning uncertainty, we are interested in portfolio management of emission permits, that is choice under uncertainty between buying, selling and banking permits. Concerning competitive distortions, we consider manipulations on the permits and/or products markets. Among others, we investigate interactions between a pollution market and the wholesale electricity market. From a general point of view, we show that a permits market, even competitive, gives to power producers more opportunities to act strategically on wholesale electricity markets. By this way, our study attempts to indicate when these market distortions are more likely to occur and to give some emissions market design instructions. (author)

  17. Decommissioning nuclear power plants. Policies, strategies and costs

    International Nuclear Information System (INIS)

    2003-01-01

    The decommissioning of nuclear power plants is a topic of increasing interest to governments and the industry as many nuclear units approach retirement. It is important in this context to assess decommissioning costs and to ensure that adequate funds are set aside to meet future financial liabilities arising after nuclear power plants are shut down. Furthermore, understanding how national policies and industrial strategies affect those costs is essential for ensuring the overall economic effectiveness of the nuclear energy sector. This report, based upon data provided by 26 countries and analysed by government and industry experts, covers a variety of reactor types and sizes. The findings on decommissioning cost elements and driving factors in their variance will be of interest to analysts and policy makers in the nuclear energy field. (author)

  18. Autonomous Control Strategy of DC Microgrid for Islanding Mode Using Power Line Communication

    Directory of Open Access Journals (Sweden)

    Dong-Keun Jeong

    2018-04-01

    Full Text Available This paper proposes a DC-bus signaling (DBS method for autonomous power management in a DC microgrid, used to improve its reliability. Centralized power management systems require communication between the power sources and loads. However, the DBS method operates based on the common DC-bus voltage and does not require communication. Based on the DC-bus voltage band, the DC-bus voltage can be used to inform the status of the DC-bus in various scenarios. The DC microgrid operates independently to maintain the system stably in the DC-bus voltage band. The DC microgrid can be divided into a grid-connected mode and an islanding mode. This paper proposes a control strategy based on power management of various independent components in islanding mode. In addition, the autonomous control method for switching the converter’s operation between grid-connected mode and islanding mode is proposed. A DC microgrid test bed consisting of a grid-connected AC/DC converter, a bidirectional DC/DC converter, a renewable energy simulator, DC home appliances and a DC-bus protector is used to test the proposed control strategy. The proposed autonomous control strategy is experimentally verified using the DC microgrid test bed.

  19. Importance of the validation of saving technologies of electric power; Importancia de la validacion de tecnologias ahorradoras de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Valer Negrete, Adrian [Programa de Ahorro de Energia del Sector Electrico (PAESE), Comision Federal de Electricidad (Mexico)

    2003-07-01

    Within the Programs of Energy Saving it is fundamental the search and application of new technologies, with which this saving can be obtained, selected with base in their technical characteristics that allow to reduce to the consumptions and demands of power, without damaging the electric networks nor the transformers of the Comision Federal de Electricidad. It is important that the investments which are made count on attractive periods of capital recovery, in comparison with the useful life of the product, reason why the knowledge and price of the new technologies will be parameters to consider in an important manner, creating the need of conducting tests that verify the veracity of the information of the supplier, resulting in certain cases, the change of design of these technologies, so that thus they fulfill the engaged characteristics. This paper indicates the characteristics that the new saving technologies of electrical energy must fulfill and the tests and parameters to consider their evaluation. [Spanish] Dentro de los Programas de Ahorro de Energia es fundamental la busqueda y aplicacion de nuevas tecnologias, con las que se pueda obtener dicho ahorro, seleccionadas con base en sus caracteristicas tecnicas que permitan reducir los consumos y demandas de potencia, sin danar las redes ni transformadores de la Comision Federal de Electricidad. Es importante que las inversiones que se realicen cuenten con periodos de recuperacion de capital atractivos, comparados con la vida util del producto, por lo que el conocimiento y precio de las nuevas tecnologias seran parametros a considerar de manera importante, creandose la necesidad de realizar pruebas que verifiquen la veracidad de la informacion del proveedor, resultando en determinados casos, el cambio de diseno de dichas tecnologias, para que asi cumplan las caracteristicas prometidas. Este trabajo indica las caracteristicas que deben cumplir las nuevas tecnologias ahorradoras de energia electrica y las

  20. Chapter 12: Survey Design and Implementation for Estimating Gross Savings Cross-Cutting Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Baumgartner, Robert [Tetra Tech, Madison, WI (United States)

    2017-10-05

    This chapter presents an overview of best practices for designing and executing survey research to estimate gross energy savings in energy efficiency evaluations. A detailed description of the specific techniques and strategies for designing questions, implementing a survey, and analyzing and reporting the survey procedures and results is beyond the scope of this chapter. So for each topic covered below, readers are encouraged to consult articles and books cited in References, as well as other sources that cover the specific topics in greater depth. This chapter focuses on the use of survey methods to collect data for estimating gross savings from energy efficiency programs.

  1. Energy-efficient multicast traffic grooming strategy based on light-tree splitting for elastic optical networks

    Science.gov (United States)

    Liu, Huanlin; Yin, Yarui; Chen, Yong

    2017-07-01

    In order to address the problem of optimizing the spectrum resources and power consumption in elastic optical networks (EONs), we investigate the potential gains by jointly employing the light-tree splitting and traffic grooming for multicast requests. An energy-efficient multicast traffic grooming strategy based on light-tree splitting (EED-MTGS-LS) is proposed in this paper. Firstly, we design a traffic pre-processing mechanism to decide the multicast requests' routing order, which considers the request's bandwidth requirement and physical hops synthetically. Then, by dividing a light-tree to some sub-light-trees and grooming the request to these sub-light-trees, the light-tree sharing ratios of multicast requests can be improved. What's more, a priority scheduling vector is constructed, which aims to improve the success rate of spectrum assignment for grooming requests. Finally, a grooming strategy is designed to optimize the total power consumption by reducing the use of transponders and IP routers during routing. Simulation results show that the proposed strategy can significantly improve the spectrum utilization and save the power consumption.

  2. POWER STRATEGY OF THE AGRICULTURE DEVELOPMENT IN THE CONDITIONS OF CRISIS

    Directory of Open Access Journals (Sweden)

    Burdo O.G.

    2009-04-01

    Full Text Available Questions of the development of energetics in the world are examined. Specifics of the energy supply in agriculture are discussed and the basics of energy policy and strategy in crisis conditions are formulated. The methodology of power monitoring and basics of economy of power management are shown. Priorities at forma-tion of stages of projects implementation are proved. Ways of energy efficiency programs creation using partial projects self–financing mechanisms are shown.

  3. Power and Energy Management Strategy for Solid State Transformer Interfaced DC Microgrid

    Science.gov (United States)

    Yu, Xunwei

    As a result of more and more applications of renewable energy into our ordinary life, how to construct a microgrid (MG) based on the distributed renewable energy resources and energy storages, and then to supply a reliable and flexible power to the conventional power system are the hottest topics nowadays. Comparing to the AC microgrid (AC MG), DC microgrid (DC MG) gets more attentions, because it has its own advantages, such as high efficiency, easy to integrate the DC energy sources and energy storages, and so on. Furthermore, the interaction between DC MG system and the distribution system is also an important and practical issue. In Future Renewable Electric Energy Delivery and Management Systems Center (FREEDM), the Solid State Transformer (SST) is built, which can transform the distribution system to the low AC and DC system directly (usually home application level). Thus, the SST gives a new promising solution for low voltage level MG to interface the distribution level system instead of the traditional transformer. So a SST interfaced DC MG is proposed. However, it also brings new challenges in the design and control fields for this system because the system gets more complicated, which includes distributed energy sources and storages, load, and SST. The purpose of this dissertation is to design a reliable and flexible SST interfaced DC MG based on the renewable energy sources and energy storages, which can operate in islanding mode and SST-enabled mode. Dual Half Bridge (DHB) is selected as the topology for DC/DC converter in DC MG. The DHB operation procedure and average model are analyzed, which is the basis for the system modeling, control and operation. Furthermore, two novel power and energy management strategies are proposed. The first one is a distributed energy management strategy for the DC MG operating in the SST-enabled mode. In this method, the system is not only in distributed control to increase the system reliability, but the power sharing

  4. Does nuclear energy save global environment?

    International Nuclear Information System (INIS)

    Matsui, Kazuaki

    2006-01-01

    Since the ecological footprint analysis in 1970s suggested changing consumption patterns and overpopulation concerns, energy policy such as energy conservation and use of renewable energy has become of prime importance. Several results of the long-term energy demand and supply analysis in 2050 or 2100 to reduce drastically carbon dioxide emission as a measure against global warming, showed the necessity of nuclear power deployment as well as maximum efforts to save energy, exploitation of the separation and disposal of carbon dioxide, and shifting energy sources to fuels that emit less greenhouse gases or non-fossil fuels. As a promising means to contribute to long-term energy supply, nuclear power generation is expected with improving safety, economic efficiency, environmental adaptability, and nuclear proliferation resistance of the technologies. (T.Tanaka)

  5. Assessment of Passive vs. Active Strategies for a School Building Design

    Directory of Open Access Journals (Sweden)

    Ji Eun Kang

    2015-11-01

    Full Text Available This paper presents a simulation study to reduce heating and cooling energy demand of a school building in Seoul Metropolitan Area, Korea. The aim of this study was to estimate the impact of passive vs. active approaches on energy savings in buildings using EnergyPlus simulation. By controlling lighting, the energy saving of the original school building design was found most significant, and increased by 32% when the design was improved. It is noteworthy that energy saving potential of each room varies significantly depending on the rooms’ thermal characteristics and orientation. Thus, the analysis of energy saving should be introduced at the individual space level, not at the whole building level. Additionally, the simulation studies should be involved for rational decision-making. Finally, it was concluded that priority should be given to passive building design strategies, such as building orientation, as well as control and utilization of solar radiation. These passive energy saving strategies are related to urban, architectural design, and engineering issues, and are more beneficial in terms of energy savings than active strategies.

  6. Studies on energy system for an energy-saving society; Sho energy gata shakai ni okeru energy system kento

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    The system to which new energy technology and energy saving technology were introduced was constructed for case studies of urban areas including core cities and the peripheral areas, and the quantitative analysis was conducted on environmental effects, etc. In the energy supply system model, the following element technologies were all considered: cogeneration system, sewage water heat, river water heat, the photovoltaic power generation, energy storage/heat storage/cold heat storage, adsorption type refrigerator, etc. Also considered were power interchange between clusters, system power buying/power selling, heat interchange or no heat interchange, etc. As a result, it was found that when constructing the energy system which synthetically takes into account thermoelectric ratios, rates of simultaneous loads, ratios of daytime/nighttime in the energy supply and demand in the urban area, the energy saving effect multiplicatively increases, and the energy system using cogeneration and unused energy such as refuse and sewage in the urban area and river water brings an energy saving effect of 32% especially in the concentrated cluster. 83 figs., 45 tabs.

  7. Cogeneration plant in a pasta factory: Energy saving and environmental benefit

    International Nuclear Information System (INIS)

    Panno, Domenico; Messineo, Antonio; Dispenza, Antonella

    2007-01-01

    Italy produces approximately 4,520,000 tons of pasta annually, which is about 67% of its total productive potential. As factories need electric and thermal energy simultaneously, combined heat and power (CHP) systems are the most suitable. This paper describes a feasibility study of a CHP plant in a pasta factory in Italy while analyzing energy saving and environmental benefits. Commercially available CHP systems suitable for the power range of energy demand in pasta production use reciprocating engines or gas turbines. This study demonstrates how their use can reduce both energy costs and CO 2 equivalent greenhouse gas emission in the environment. An economic analysis was performed following the methodology set out by Italian National Agency for Technology, Energy and Environment (ENEA) based on a discounted cash flow (DCF) method called 'Valore Attuale Netto' (VAN), which uses a cash flow based on the saving of energy when using different energy processes

  8. Numerical simulation of the integrated solar/North Benghazi combined power plant

    International Nuclear Information System (INIS)

    Aldali, Y.; Morad, K.

    2016-01-01

    Highlights: • The thermodynamic and economic evaluation of power plant have been studied. • Saving and boosting modes are considered as the same solar field area. • Two modes of operation have been used and simulated on Libyan climate conditions. • The benefit/cost ratios are 1.74 and 1.30 for fuel saving and power boosting mode. • Fuel saving mode is more economical than power boosting mode. - Abstract: The aim of this paper is to study the thermodynamic performance of a proposed integrated solar/North Benghazi combined power plant under Libyan climatic conditions. The parabolic trough collector field with direct steam generation was considered as solar system. Two modes of operations with the same solar field area are considered: fuel saving mode in which the generated solar steam was used to preheat the combustion air in the gas turbine unit and power boosting mode in which the generated solar steam was added into the steam turbine for boosting the electrical power generated from steam turbine unit. Moreover, the economic impact of solar energy is assessed in the form of benefit/cost ratio to justify the substitution potential of such clean energy. This study shows that, for fuel saving mode: the annual saving of natural gas consumption and CO_2 emission are approximately 3001.56 and 7972.25 tons, respectively, in comparison with the conventional North Benghazi combined cycle power plant. For power boosting mode: the annual solar share of electrical energy is approximately 93.33 GW h. The economic analysis of solar supported plant has indicated that the benefit/cost ratios are 1.74 and 1.30 for fuel saving and power boosting mode, therefore, then fuel saving mode is more economical than power boosting mode for the same solar field area, moreover, it reduces the greenhouse CO_2 emission in order to avoid a collapse of the word climate.

  9. 76 FR 31680 - General Reporting and Recordkeeping by Savings Associations and Savings and Loan Holding Companies

    Science.gov (United States)

    2011-06-01

    ... Savings Associations and Savings and Loan Holding Companies AGENCY: Office of Thrift Supervision (OTS... Savings and Loan Holding Companies. OMB Number: 1550-0011. Form Number: N/A. Description: This information...), 12 CFR 562.4 (audit of savings association, savings and loan holding company, or affiliate), 12 CFR...

  10. Overall strategy of Creys Malville power station dismantling

    International Nuclear Information System (INIS)

    Alphonse, P.

    2002-01-01

    The power station was stopped by a government decision following the elections in 1997. This shutdown was then made official by a letter dated April 1998 and the decree of December 1998. This was a non-technical shutdown and as such had not been envisaged; there has been no early warning. Current dismantling strategy: The studies leading to shutdown and then dismantling were engaged in 1998 based on a scenario with a status corresponding to IAEA level 2 until 2046. In 2001, EDF management made the decision to dismantle all the first generation power stations and Creys Malville between now and 2025. It should be noted that the presence of strongly irradiated stellite in the Creys Malville reactor would still require remote systems for working in the reactor block after 2046. The sequence of operations dictated by the dismantling strategy is as follows: eliminate the risks as soon as possible and in particular the risk related to the sodium, 3300 tonnes of which is kept in liquid form in the reactor vessel; dismantle the most active parts which are too radioactive to be sent to the existing or planned storage centres. This may lead to on-site storage to allow decay to occur before sending to a storage centre; planning of the work interventions in order to limit the costs

  11. 12 CFR 583.21 - Savings association.

    Science.gov (United States)

    2010-01-01

    ... AFFECTING SAVINGS AND LOAN HOLDING COMPANIES § 583.21 Savings association. The term savings association means a Federal savings and loan association or a Federal savings bank chartered under section 5 of the Home Owners' Loan Act, a building and loan, savings and loan or homestead association or a cooperative...

  12. A simple tool for estimating city-wide annual electrical energy savings from cooler surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Pomerantz, Melvin; Rosado, Pablo J.; Levinson, Ronnen

    2015-12-01

    We present a simple method to estimate the maximum possible electrical energy saving that might be achieved by increasing the albedo of surfaces in a large city. We restrict this to the “indirect effect”, the cooling of outside air that lessens the demand for air conditioning (AC). Given the power demand of the electric utilities and data about the city, we can use a single linear equation to estimate the maximum savings. For example, the result for an albedo change of 0.2 of pavements in a typical warm city in California, such as Sacramento, is that the saving is less than about 2 kWh per m2 per year. This may help decision makers choose which heat island mitigation techniques are economical from an energy-saving perspective.

  13. The EKZ goes to its customers: A mobile exhibition on energy saving. Die EKZ gehen zu ihren Kunden: Rollende Austellungen ueber Energiesparen

    Energy Technology Data Exchange (ETDEWEB)

    Kurth, R.; Starkemann, B. (Elektrizitaetswerke Zurich (Switzerland))

    1991-09-18

    The Elektrizitaetswerke des Kantons Zuerich (EKZ) is bringing the subject of power and energy-saving closer to its customers with mobile exhibitions. Starting in the autumn of 1991, three new exhibition vehicles will be touring around the EKZ supply area they will give information on modern forms of lighting with power-saving light bulbs, on the heating of buildings by means of electrical heat pumps, on microwave appliances and power production from solar energy. (orig.).

  14. Evaluation of SO2 compliance strategies at Virginia Power

    International Nuclear Information System (INIS)

    Presley, J.V.; Tomlinson, M.; Ulmer, R.H.

    1992-01-01

    This paper will address the process undertaken by Virginia Power to assess SO 2 control strategies available for complying with the Revised Clean Air Act. In April 1990, in anticipation of the passage of an amended Clean Air Act, Virginia Power assembled a task force of personnel from a wide cross section of the company. This task force was given the responsibility of providing an assessment of the requirements of the new legislation, evaluating compliance alternatives and providing recommendations for implementation of the least cost alternative. Twenty-four potential SO 2 compliance options were identified for evaluation for Phase I. These options included various levels of coal switching, gas co-firing and scrubbing. Each option was evaluated and compared to a base case which assumed no SO 2 control. As a result of our evaluations, the lowest cost and least risk approach to Phase I SO 2 compliance for Virginia Power appears to be to construct a scrubber for one unit (550 MW g ) at our Mt. Storm Power Station

  15. Optimal operation strategy of battery energy storage system to real-time electricity price in Denmark

    DEFF Research Database (Denmark)

    Hu, Weihao; Chen, Zhe; Bak-Jensen, Birgitte

    2010-01-01

    markets in some ways, is chosen as the studied power system in this paper. Two kinds of BESS, based on polysulfide-bromine (PSB) and vanadium redox (VRB) battery technologies, are studies in the paper. Simulation results show, that the proposed optimal operation strategy is an effective measure to achieve......Since the hourly spot market price is available one day ahead, the price could be transferred to the consumers and they may have some motivations to install an energy storage system in order to save their energy costs. This paper presents an optimal operation strategy for a battery energy storage...

  16. Fuel saving and emissions cut through shore-side power concept for high-speed crafts at the red sea in egypt

    Science.gov (United States)

    Seddiek, Ibrahim S.; Mosleh, Mosaad A.; Banawan, Adel A.

    2013-12-01

    The progress of economic globalization, the rapid growth of international trade, and the maritime transportation has played an increasingly significant role in the international supply chain. As a result, worldwide seaports have suffered from a central problem, which appears in the form of massive amounts of fuel consumed and exhaust gas fumes emitted from the ships while berthed. Many ports have taken the necessary precautions to overcome this problem, while others still suffer due to the presence of technical and financial constraints. In this paper, the barriers, interconnection standards, rules, regulations, power sources, and economic and environmental analysis related to ships, shore-side power were studied in efforts to find a solution to overcome his problem. As a case study, this paper investigates the practicability, costs and benefits of switching from onboard ship auxiliary engines to shore-side power connection for high-speed crafts called Alkahera while berthed at the port of Safaga, Egypt. The results provide the national electricity grid concept as the best economical selection with 49.03 percent of annual cost saving. Moreover, environmentally, it could achieve an annual reduction in exhaust gas emissions of CO2, CO, NO x , P.M, and SO2 by 276, 2.32, 18.87, 0.825 and 3.84 tons, respectively.

  17. Soft power as part of China's strategy for national image cultivation

    DEFF Research Database (Denmark)

    Overgaard, Signe

    In recent years soft power has become a key issue at the highest political level in China, focusing especially on cultural soft power. This is reflected in important political documents, such as five year plans, plenum meeting summaries, as well as speeches by Hu Jintao and other politicians...... at the highest level. This interest in soft power is generally seen as part of an important foreign policy shift, and the huge amounts of money spent by the government on cultural diplomacy testify to the importance attached to it. Understanding what might be the goal of China’s soft power strategy is however...... difficult. The question can be analysed from various perspectives focusing on the use of power, the peaceful development discourse, or national image cultivation, and finding a straight forward answer is therefore difficult. If we go deeper and see the soft power discourse in the context of the worries...

  18. Some problems of recent 'All Japan' strategy for nuclear power exports. Identification of its problems and a proposal for improvement based on international development strategies of the major three categories of businesses constituting nuclear power industry

    International Nuclear Information System (INIS)

    Tanabe, Tomoyuki

    2011-01-01

    In Japan, 'All Japan' strategy for nuclear power exports, which arranges engineering companies and electric utilities to sell nuclear power plants providing engineering, procurement, construction and operation abroad, with governmental support of expanded trade insurance, is strongly promoted today as a part of Japan's national growth strategy. However, 'All Japan' strategy generates some problems because the strategy does not consider difference of business strategies concerning international development of each enterprise. This report identifies problems of 'All Japan' strategy based on environmental scanning of major three categories of businesses, which are big nuclear technology companies, vendors and electric utilities constituting nuclear power industry. And this report proposes the way to improve the strategy as follows to resolve those problems. 1) It is necessary to assess the risk of the project that is to be undertaken by 'All Japan' approach carefully. 2) Governmental support for vendors is also needed because the vendors are source of strength of international development of the nuclear industry in Japan. 3) Where the cooperation among the electric utilities is necessary, imposing the risk burden on the utilities should be avoided. 4) It is necessary for government to take measures about 'Weakness' and 'Threat' that each category of business commonly faces. (author)

  19. Microgrid Control Strategy Utlizing Thermal Energy Storage With Renewable Solar And Wind Power Generation

    Science.gov (United States)

    2016-06-01

    iii Approved for public release; distribution is unlimited MICROGRID CONTROL STRATEGY UTLIZING THERMAL ENERGY STORAGE WITH RENEWABLE SOLAR AND WIND... control tracks increasing power generation in the morning. The batteries require a large amount of electrical power to charge every morning, as charge ...is 37 lost throughout the night. This causes the solar panels to output their maximum power generation. The MPPT control records when power

  20. LED Lightbulbs as a Source of Electricity Saving in Buildings

    Directory of Open Access Journals (Sweden)

    Zeb Akhtar

    2016-01-01

    Full Text Available Today a number of renewable energy technologies are available for power generation, but fossil fuels are still providing a dominant share nevertheless. In order to decrease the electric bill and save our environment, energy conservation is always crucial. In this paper a very interesting idea is presented which is economically viable to reduce electricity usage in our buildings. An effort has been made to estimate the amount of energy that could be saved in the dormitory section of the IMOP building in Russia. Although there are many ways to reduce the consumption of electricity in this building but here the emphasis is on changing light bulbs inside the rooms, kitchen, toilet and bathroom of each apartment. The scope of the study is to figure out monthly electricity saving by replacing traditional light bulbs by LED light bulbs in the building under consideration. The total investment required and the payback period is also presented.

  1. Start point to savings - Better load demand analysis in commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Abaravicius, Juozas; Pyrko, Jurek [Lund Univ., Dept of Energy Sciences (Sweden)

    2007-07-01

    Existing installations and energy systems in most commercial buildings could be used in a more efficient way to provide savings - both in terms of energy and load demand. The key for effective operation is a thorough and detailed analysis of energy use patterns that creates essential baseline for energy savings and the development of demand response (DR) strategies. The knowledge of energy demand variations is still very limited and the use of methods to analyse the load demand is rare. Many utilities have recently installed interval (hourly) metering even for smaller commercial users and households. This is a big step forward; however, experience shows that the data is being used only to a limited extent, mostly for billing purposes only. This paper reports about a study conducted with the objective of developing a detailed load demand analysis for commercial buildings. The study results should provide essential information for the formation and evaluation of future DR and energy efficiency strategies. This study was performed in collaboration with IKEA and E.ON and contributes to an ongoing IKEA energy efficiency programme. Two sample department stores in Sweden were selected and analysed within this project. The demand data analysis covers almost 3 years period, 2004-2006.This study contributes to new knowledge of energy use patterns (load demand) in commercial buildings. It proposes solutions of load-related problems, evaluates energy and load savings potential, identifies and analyses the needs, motives and barriers for participation in DR programmes. The study provides recommendations for ongoing and future efficiency and DR strategies and discusses the potential economic benefits from the DR measures.

  2. Review of Active and Reactive Power Sharing Strategies in Hierarchical Controlled Microgrids

    DEFF Research Database (Denmark)

    Han, Yang; Li, Hong; Shen, Pan

    2017-01-01

    Microgrids consist of multiple parallel-connected distributed generation (DG) units with coordinated control strategies, which are able to operate in both grid-connected and islanded mode. Microgrids are attracting more and more attention since they can alleviate the stress of main transmission...... systems, reduce feeder losses, and improve system power quality. When the islanded microgrids are concerned, it is important to maintain system stability and achieve load power sharing among the multiple parallel-connected DG units. However, the poor active and reactive power sharing problems due...... in this paper for active power sharing. Moreover, nonlinear and unbalanced loads could further affect the reactive power sharing when regulating the active power, and it is difficult to share the reactive power accurately only by using the enhanced virtual impedance method. Therefore, the hierarchical control...

  3. Design of Energy Storage Control Strategy to Improve the PV System Power Quality

    DEFF Research Database (Denmark)

    Lei, Mingyu; Yang, Zilong; Wang, Yibo

    2016-01-01

    Random fluctuation of PV power is becoming a more and more serious problem affecting the power quality and stability of grid as the PV penetration keeps increasing recent years. Aiming at this problem, this paper proposed a control strategy of energy storage system based on Model Predictive Contr...

  4. Impact of DC link control strategies on the power-flow convergence of integrated AC–DC systems

    Directory of Open Access Journals (Sweden)

    Shagufta Khan

    2016-03-01

    Full Text Available For the power-flow solution of integrated AC–DC systems, five quantities are required to be solved per converter, against three independent equations available. These three equations consist of two basic converter equations and one DC network equation, corresponding to each converter. Thus, for solution, two additional equations are required. These two equations are derived from the control specifications adopted for the DC link. Depending on the application, several combinations of valid control specifications are possible. A set of valid control specifications constitutes a control strategy. It is observed that the control strategy adopted for the DC link strongly affects the power-flow convergence of integrated AC–DC systems. This paper investigates how different control strategies affect the power flow convergence of integrated AC–DC systems. Sequential method is used to solve the DC variables in the Newton Raphson (NR power flow model. Seven typical control strategies have been taken into consideration. This is validated by numerous case studies carried out with multiple DC links incorporated in the IEEE 118-bus and 300-bus test systems.

  5. Energy management strategies for combined heat and electric power micro-grid

    Directory of Open Access Journals (Sweden)

    Barbarić Marina

    2016-01-01

    Full Text Available The increasing energy production from variable renewable energy sources such as wind and solar has resulted in several challenges related to the system reliability and efficiency. In order to ensure the supply-demand balance under the conditions of higher variability the micro-grid concept of active distribution networks arising as a promising one. However, to achieve all the potential benefits that micro-gird concept offer, it is important to determine optimal operating strategies for micro-grids. The present paper compares three energy management strategies, aimed at ensuring economical micro-grid operation, to find a compromise between the complexity of strategy and its efficiency. The first strategy combines optimization technique and an additional rule while the second strategy is based on the pure optimization approach. The third strategy uses model based predictive control scheme to take into account uncertainties in renewable generation and energy consumption. In order to compare the strategies with respect to cost effectiveness, a residential micro-grid comprising photovoltaic modules, thermal energy storage system, thermal loads, electrical loads as well as combined heat and power plant, is considered.

  6. Pelvic movement strategies and leg extension power in patients with end-stage medial compartment knee osteoarthritis

    DEFF Research Database (Denmark)

    Kierkegaard, Signe; Jørgensen, Peter Bo; Dalgas, Ulrik

    2015-01-01

    advancing functional tasks, and how these strategies are associated with leg extension power. The aim of the study was to investigate pelvic movement strategies and leg extension power in patients with end-stage medial compartment knee osteoarthritis compared with controls. MATERIALS AND METHODS: 57...... patients (mean age 65.6 years) scheduled for medial uni-compartmental knee arthroplasty, and 29 age and gender matched controls were included in this cross-sectional study. Leg extension power was tested with the Nottingham Leg Extension Power-Rig. Pelvic range of motion was derived from an inertia......-based measurement unit placed over the sacrum bone during walking, stair climbing and stepping. RESULTS: Patients had lower leg extension power than controls (20-39 %, P

  7. Development and analysis of an economizer control strategy algorithm to promote an opportunity for energy savings in air conditioning installations

    Energy Technology Data Exchange (ETDEWEB)

    Neto, Jose H.M.; Azevedo, Walter L. [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET), Belo Horizonte, MG (Brazil). Dept. de Engenharia Mecanica]. E-mail: henrique@daem.des.cefetmg.br

    2000-07-01

    This work presents an algorithm control strategy denominated enthalpy economizer. The objective of this algorithm strategy is to determine the adequate fractions of outside and return air flowrates entering a cooling coil based on the analysis of the outside, return and supply air enthalpies, rather than on the analysis of the dry bulb temperatures. The proposed algorithm predicts the actual opening position of the outside and return air dampers in order to provide the lower mixing air enthalpy. First, the psychometrics properties of the outside and return air are calculated from actual measurements of the dry and wet bulb temperatures. Then, three distinct cases are analyzed: the enthalpy of the outside air is lower than the enthalpy of the supply air (free cooling); the enthalpy of the outside air is higher than the enthalpy of the return air; the enthalpy of the outside air is lower than the enthalpy of the return air and higher than the temperature of the supply air. Different outside air conditions were selected in order to represent typical weather data of Brazilians cities, as well as typical return air conditions. It was found that the enthalpy control strategy could promote an opportunity for energy savings mainly during mild nights and wintertime periods as well as during warm afternoons and summertime periods, depending on the outside air relative humidity. The proposed algorithm works well and can be integrated in some commercial automation software to reduce energy consumption and electricity demand. (author)

  8. Design of a nonlinear backstepping control strategy of grid interconnected wind power system based PMSG

    Science.gov (United States)

    Errami, Y.; Obbadi, A.; Sahnoun, S.; Benhmida, M.; Ouassaid, M.; Maaroufi, M.

    2016-07-01

    This paper presents nonlinear backstepping control for Wind Power Generation System (WPGS) based Permanent Magnet Synchronous Generator (PMSG) and connected to utility grid. The block diagram of the WPGS with PMSG and the grid side back-to-back converter is established with the dq frame of axes. This control scheme emphasises the regulation of the dc-link voltage and the control of the power factor at changing wind speed. Besides, in the proposed control strategy of WPGS, Maximum Power Point Tracking (MPPT) technique and pitch control are provided. The stability of the regulators is assured by employing Lyapunov analysis. The proposed control strategy for the system has been validated by MATLAB simulations under varying wind velocity and the grid fault condition. In addition, a comparison of simulation results based on the proposed Backstepping strategy and conventional Vector Control is provided.

  9. Control Strategy for Power Distribution in Dual Motor Propulsion System for Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Pedro Daniel Urbina Coronado

    2015-01-01

    Full Text Available Electric Vehicles with more than one electric motor can offer advantages in saving energy from the batteries. In order to do that, the control strategy plays an important role in distributing the required torque between the electric motors. A dual motor propulsion system with a differential transmission is simulated in this work. A rule based control strategy for this propulsion system is proposed and analyzed. Two parameters related to the output speed of the transmission and the required torque are used to switch the two modes of operation in which the propulsion system can work under acceleration. The effect of these parameters is presented over the driving cycles of NEDC, UDDS, and NYCC, which are followed using a PID controller. The produced energy losses are calculated as well as an indicator of drivability, which is related to the difference between the desired speed and the actual speed obtained. The results show that less energy losses are present when the vehicle is maintained with one electric motor most of the time, switching only when the extended speed granted by the second motor is required. The propulsion system with the proposed control strategy represents a feasible alternative in the spectrum of sustainable transportation architectures with extending range capabilities.

  10. Save Energy: Save Money!

    Science.gov (United States)

    Eccli, Eugene; And Others

    This publication is a collection of inexpensive energy saving tips and home improvements for home owners, particularly in low-income areas or in older homes. Section titles are: (1) Keeping Warm; (2) Getting Heat Where You Need It; (3) Using the Sun; (4) Furnaces, Stoves, and Fireplaces; (5) Insulation and Other Energy Needs; (6) Do-It-Yourself…

  11. Energy Efficiency Strategies for Municipal Wastewater Treatment Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Daw, J.; Hallett, K.; DeWolfe, J.; Venner, I.

    2012-01-01

    Water and wastewater systems are significant energy consumers with an estimated 3%-4% of total U.S. electricity consumption used for the movement and treatment of water and wastewater. Water-energy issues are of growing importance in the context of water shortages, higher energy and material costs, and a changing climate. In this economic environment, it is in the best interest for utilities to find efficiencies, both in water and energy use. Performing energy audits at water and wastewater treatment facilities is one way community energy managers can identify opportunities to save money, energy, and water. In this paper the importance of energy use in wastewater facilities is illustrated by a case study of a process energy audit performed for Crested Butte, Colorado's wastewater treatment plant. The energy audit identified opportunities for significant energy savings by looking at power intensive unit processes such as influent pumping, aeration, ultraviolet disinfection, and solids handling. This case study presents best practices that can be readily adopted by facility managers in their pursuit of energy and financial savings in water and wastewater treatment. This paper is intended to improve community energy managers understanding of the role that the water and wastewater sector plays in a community's total energy consumption. The energy efficiency strategies described provide information on energy savings opportunities, which can be used as a basis for discussing energy management goals with water and wastewater treatment facility managers.

  12. Control strategies to optimise power output in heave buoy energy convertors

    International Nuclear Information System (INIS)

    Abu Zarim, M A U A; Sharip, R M

    2013-01-01

    Wave energy converter (WEC) designs are always discussed in order to obtain an optimum design to generate the power from the wave. Output power from wave energy converter can be improved by controlling the oscillation in order to acquire the interaction between the WEC and the incident wave.The purpose of this research is to study the heave buoys in the interest to generate an optimum power output by optimising the phase control and amplitude in order to maximise the active power. In line with the real aims of this study which investigate the theory and function and hence optimise the power generation of heave buoys as renewable energy sources, the condition that influence the heave buoy must be understand in which to propose the control strategies that can be use to control parameters to obtain optimum power output. However, this research is in an early stage, and further analysis and technical development is require

  13. Implementing the strategy of multileveled PI activities to promote rapid nuclear power development

    International Nuclear Information System (INIS)

    Chen Gang

    2005-01-01

    The first two decades of the 21st century is the golden time for nuclear power development in China. According to the nuclear power development program laid down by the State Development and Reform Commission, nearly 30 units of 1000MW will be built in the next 15 years, so as to meet fastgrowing energy demand, to optimize energy mix and to alleviate environmental pollution. Under such a new situation, based on the public information practice and experience during the construction and operation of Qinshan Nuclear Power Complex where the first commercial NPP originated in the Mainland of China, this paper emphasizes on the necessity of establishment of an active and open strategy of multileveled nuclear energy public information activities and implementation of the strategy with adoption of various forms of nuclear energy popularization means, including seminars, contests, exhibitions, site tour to nuclear power plants, reports by mass media, hosting questions-answering dialogue by experts via Internet, TV and radio programs, newspapers and journals , etc.. Thus through the nuclear energy public information activity the recognition and confidence of the public, especially the local community and the public in vicinity of new nuclear power sites on the nuclear energy can be enhanced, and the nuclear power program can gain their support. Furthermore, the fine social environment for nuclear power development can be fostered. (authors)

  14. Strategies for the co-operation between power generation facilities and power sales organisations in the European electricity market

    International Nuclear Information System (INIS)

    Bammert, U.

    2003-01-01

    This article discusses how the public utilities in Hannover, Germany, have developed a strategy for the operation of their power generation facilities and power distribution network as independent yet co-operating units. Three models that were examined are described: 'free-sailing', where generation and distribution were kept completely independent, the 'wedding' model, where they were closely tied together and 'Enercity', a mixture of both models. The various rules necessary and the degrees of freedom needed to implement the 'Enercity' model are discussed, as are the advantages it offers to both the power generation and the sales units

  15. Students’ goal orientations and learning strategies in a powerful learning environment : a case study

    NARCIS (Netherlands)

    Koopman, M.; Bakx, A.W.E.A.; Beijaard, D.

    2014-01-01

    In Dutch secondary education, experiments with powerful social constructivist learning environments are conducted that aim to appeal to students’ intrinsic goal orientations, use of deep cognitive learning strategies, and self-direction of meta-cognitive learning strategies. The aim of this study is

  16. Contract saving schemes

    NARCIS (Netherlands)

    Ronald, R.; Smith, S.J.; Elsinga, M.; Eng, O.S.; Fox O'Mahony, L.; Wachter, S.

    2012-01-01

    Contractual saving schemes for housing are institutionalised savings programmes normally linked to rights to loans for home purchase. They are diverse types as they have been developed differently in each national context, but normally fall into categories of open, closed, compulsory, and ‘free

  17. A study of implementing In-Cycle-Shuffle strategy to a decommissioning boiling water reactor

    International Nuclear Information System (INIS)

    Chen, Chung-Yuan; Tung, Wu-Hsiung; Yaur, Shyun-Jung

    2017-01-01

    Highlights: • A loading pattern strategy ICS (In-Cycle-Shuffle) was implemented to the last cycle of the boiling water reactor. • The best power sharing distribution and ICS timing was found. • A new parameter “Burnup sharing” is presented to evaluate ICS strategy. - Abstract: In this paper, a loading pattern strategy In-Cycle-Shuffle (ICS) is implemented to the last cycle of the boiling water reactor (BWR) before decommissioning to save the fuel cycle cost. This method needs a core shutdown during the operation of a cycle to change the loading pattern to gain more reactivity. The reactivity model is used to model the ICS strategy in order to find out the best ICS timing and the optimum power sharing distribution before ICS and after ICS. Several parameters of reactivity model are modified and the effect of burnable poison, gadolinium (Gd), is considered in this research. Three cases are presented and it is found that the best ICS timing is at about two-thirds of total cycle length no matter the poisoning effect of Gd is considered or not. According to the optimum power sharing distribution result, it is suggested to decrease the once burnt power and increase the thrice burnt fuel power as much as possible before ICS. After ICS, it is suggested to increase the positive reactivity fuel power and decrease the thrice burnt fuel power as much as possible. A new parameter “Burnup sharing” is presented to evaluate the special case whose EOC power weighting factor and the burnup accumulation factor in the reactivity model are quite different.

  18. A study of implementing In-Cycle-Shuffle strategy to a decommissioning boiling water reactor

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chung-Yuan, E-mail: tuckjason@iner.gov.tw; Tung, Wu-Hsiung; Yaur, Shyun-Jung

    2017-06-15

    Highlights: • A loading pattern strategy ICS (In-Cycle-Shuffle) was implemented to the last cycle of the boiling water reactor. • The best power sharing distribution and ICS timing was found. • A new parameter “Burnup sharing” is presented to evaluate ICS strategy. - Abstract: In this paper, a loading pattern strategy In-Cycle-Shuffle (ICS) is implemented to the last cycle of the boiling water reactor (BWR) before decommissioning to save the fuel cycle cost. This method needs a core shutdown during the operation of a cycle to change the loading pattern to gain more reactivity. The reactivity model is used to model the ICS strategy in order to find out the best ICS timing and the optimum power sharing distribution before ICS and after ICS. Several parameters of reactivity model are modified and the effect of burnable poison, gadolinium (Gd), is considered in this research. Three cases are presented and it is found that the best ICS timing is at about two-thirds of total cycle length no matter the poisoning effect of Gd is considered or not. According to the optimum power sharing distribution result, it is suggested to decrease the once burnt power and increase the thrice burnt fuel power as much as possible before ICS. After ICS, it is suggested to increase the positive reactivity fuel power and decrease the thrice burnt fuel power as much as possible. A new parameter “Burnup sharing” is presented to evaluate the special case whose EOC power weighting factor and the burnup accumulation factor in the reactivity model are quite different.

  19. Estimation on oil demand and oil saving potential of China's road transport sector

    International Nuclear Information System (INIS)

    Lin, Boqiang; Xie, Chunping

    2013-01-01

    China is currently in the stage of industrialization and urbanization, which is characterized by rigid energy demand and rapid growth of energy consumption. Therefore, energy conservation will become a major strategy for China in a transition to low-carbon economy. China's transport industry is of high energy consumption. In 2010, oil consumption in transport industry takes up 38.2% of the country's total oil demand, of which 23.6% is taken up by road transport sector. As a result, oil saving in China's road transport sector is vital to the whole nation. The co-integration method is developed to find a long-run relationship between oil consumption and affecting factors such as GDP, road condition, labor productivity and oil price, to estimate oil demand and to predict future oil saving potential in China's transport sector under different oil-saving scenarios. Monte Carlo simulation is further used for risk analysis. Results show that under BAU condition, oil demand of China's road transport sector will reach 278.5 million ton of oil equivalents (MTOE) in 2020. Oil saving potential will be 86 MTOE and 131 MTOE under moderate oil-saving scenario and advanced oil-saving scenario, respectively. This paper provides a reference to establishing oil saving policy for China's road transport sector. - Highlights: • We adopt the co-integration model to estimate oil demand and oil saving potential of China's road transport sector. • Monte Carlo simulation is further used for risk analysis. • GDP, ratio of classified highway, labor productivity and oil price are main factors affecting oil consumption. • Scenario analysis approach is applied to calculate oil saving potential under different energy saving scenarios. • Future policy for oil conservation in China's road transport sector is suggested

  20. Power plant technology 2014. Strategies, systems engineering and operation; Kraftwerkstechnik 2014. Strategien, Anlagentechnik und Betrieb

    Energy Technology Data Exchange (ETDEWEB)

    Beckmann, Michael; Hurtado, Antonio

    2014-07-01

    The book on power plant technology 2014 (strategies, systems engineering and operation) covers the following issues: Climate, politics and economy; wind power; fossil-fuel power plants, flexible power plants - plant operation, flexible power plants- materials, materials for energy technology, fuel feed and incineration, modeling of the water-vapor-circuit, corrosion, deposits and cleaning, vapor turbines, GUD power plants, fluidized bed combustion, energetic biomass use, combined heat and power generation and decentralized units, storage facilities, emissions - mitigation and measuring techniques.

  1. Regenerative Braking Compensatory Control Strategy Considering CVT Power Loss for Hybrid Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Yang Yang

    2018-02-01

    Full Text Available Hybrid electric vehicles (HEV equipped with continuously variable transmission (CVT adjust the motor operating point continuously to achieve the optimal motor operating efficiency during regenerative braking. Traditional control strategies consider the CVT efficiency as constant, while the CVT efficiency varies in different operating conditions. In order to reflect the transmission efficiency more accurately during regenerative braking, the CVT theoretical torque loss model is firstly established which then leads to the battery–front motor–CVT joint operating efficiency model. The joint operating efficiency model indicates that the system efficiency is influenced by input speed, input torque, CVT speed ratio, and battery SOC (state of charge. The compensatory strategy for the front motor barking force is proposed to make full use of its braking power and the CVT speed ratio control strategy is modified to maintain the optimal operating efficiency of the system. The simulations are performed under three typical braking conditions and UDDS, NYCC, US06 respectively, the results show that the modified control strategy increases the front motor braking power and improves the system operating efficiency.

  2. REMINDER: Saved Leave Scheme (SLS)

    CERN Multimedia

    2003-01-01

    Transfer of leave to saved leave accounts Under the provisions of the voluntary saved leave scheme (SLS), a maximum total of 10 days'* annual and compensatory leave (excluding saved leave accumulated in accordance with the provisions of Administrative Circular No 22B) can be transferred to the saved leave account at the end of the leave year (30 September). We remind you that unused leave of all those taking part in the saved leave scheme at the closure of the leave year accounts is transferred automatically to the saved leave account on that date. Therefore, staff members have no administrative steps to take. In addition, the transfer, which eliminates the risk of omitting to request leave transfers and rules out calculation errors in transfer requests, will be clearly shown in the list of leave transactions that can be consulted in EDH from October 2003 onwards. Furthermore, this automatic leave transfer optimizes staff members' chances of benefiting from a saved leave bonus provided that they ar...

  3. Advanced maintenance strategies for power plant operators - introducing inter-plant life cycle management. ZES research focus 'condition-based maintenance in power engineering'

    Energy Technology Data Exchange (ETDEWEB)

    Graeber, U.

    2003-07-01

    The optimisation of maintenance activities observed in recent years can be attributed above all to the use and continuing development of testing and diagnostic techniques, to the increased level of system and component automation and to more efficient work organisation. Despite the considerable success of these efforts, the potential for further cost reductions is still far from exhausted. The risks connected to reliability, availability and safety need to be analysed in greater detail in order to ensure the sustainability of the savings already achieved as well as those yet to be realised. The systematic application of condition-based maintenance and the introduction of structured life cycle management are essential prerequisites. Within the framework of its ''Condition-Based Maintenance in Power Engineering'' research focus, the Energy Research Centre (ZES) has set up a specialist network in which experts from various institutes belonging to the Faculty of Mechanical Engineering and the Faculty of Informatic, Electrical Engineering and Information Technology can develop interdisciplinary solutions for advanced maintenance strategies. The ZES offers the industry a platform for cooperating on current issues relating to the supply of energy and supports the movement towards sustainable improvements to competitiveness through research and consulting activities. It applies professional project and quality management procedures to ensure that contracts covering interdisciplinary topics and projects are handled in a coherent manner. (orig.)

  4. A new strategy of axial power distribution control based on three axial offsets concept

    International Nuclear Information System (INIS)

    Shimazu, Yoichiro

    2009-01-01

    We have proposed a very simple control procedure for axial xenon oscillation control based on a characteristic trajectory. The trajectory is drawn by three offsets of power distributions, namely, AOp, AOi and AOx. They are defined as the offset of axial power distribution, the offset of the power distribution under which the current iodine distribution is obtained as the equilibrium and that for xenon distribution, respectively. When these offsets are plotted on X-Y plane for (AOp-AOx, AOi-AOx) the trajectory draws a quite characteristic ellipse (or an elliptic spiral). On the other hands, Constant Axial Offset Control (CAOC) procedure is adopted as axial power distribution control strategy during both base load and load following operations in domestic PWRs. In the previous paper, we have presented an innovative procedure of axial power distribution control during load following in PWRs based on this trajectory such that the AOp-AOx is to be controlled to zero when the value deviates the pre-determined limiting values. In this paper we propose a modified control strategy to get more stability of axial power distributions. In this strategy, we control the trajectory to be close to the major axis of the ellipse when the power distribution reaches the limiting values. In other words, the plot is not controlled only to reduce AOp-AOx but also AOi-AOx is taken into account at the same time. It is known that when the plot is controlled to the major axis, it means that the point gives the peak position of axial xenon oscillation. Therefore xenon oscillation will not increase its amplitude any more. Thus more stable axial power distribution control is attained. This kind of design concept is quite important especially for the future PWRs with elongated fuel length and longer core life. Because in a longer effective core and also the longer core life, it has been known that the stability of axial xenon oscillation becomes more unstable. In this paper, some simulation

  5. Utility-Marketer Partnerships. An Effective Strategy for Marketing Green Power?

    Energy Technology Data Exchange (ETDEWEB)

    Bird, L. A. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Brown, E. S. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2006-04-01

    This paper explores whether partnerships between utilities and independent marketers are an effective strategy for marketing green power. We present case studies of voluntary and mandatory partnerships covering green power program design and implementation in both regulated and restructured electricity markets. We also include perspectives (based on interviews) from utilities, marketers, and regulators involved in developing and implementing these partnerships. From these case studies and interviews, we describe lessons learned about developing effective partnerships, including such issues as respective roles in marketing and administration, product branding, and contract and incentive structures. Based on experience to date, strategic partnerships between utilities and marketers can be an effective approach to marketing green power. Partnerships leverage the sales and resource procurement experience of marketers and the utility’s reputation and access to customers. Further, partnerships can create greater incentives for success because marketers have a vested financial interest in maximizing customer participation and green power sales.

  6. Utility-Marketing Partnerships: An Effective Strategy for Marketing Green Power?

    Energy Technology Data Exchange (ETDEWEB)

    Bird, L. A.; Brown, E. S.

    2006-04-01

    This paper explores whether partnerships between utilities and independent marketers are an effective strategy for marketing green power. We present case studies of voluntary and mandatory partnerships covering green power program design and implementation in both regulated and restructured electricity markets. We also include perspectives (based on interviews) from utilities, marketers, and regulators involved in developing and implementing these partnerships. From these case studies and interviews, we describe lessons learned about developing effective partnerships, including such issues as respective roles in marketing and administration, product branding, and contract and incentive structures. Based on experience to date, strategic partnerships between utilities and marketers can be an effective approach to marketing green power. Partnerships leverage the sales and resource procurement experience of marketers and the utility?s reputation and access to customers. Further, partnerships can create greater incentives for success because marketers have a vested financial interest in maximizing customer participation and green power sales.

  7. 31 CFR 351.47 - May I purchase definitive Series EE savings bonds through a payroll savings plan?

    Science.gov (United States)

    2010-07-01

    ... savings bonds through a payroll savings plan? 351.47 Section 351.47 Money and Finance: Treasury....47 May I purchase definitive Series EE savings bonds through a payroll savings plan? You may purchase... maintains a payroll savings plan. An authorized issuing agent must issue the bonds. ...

  8. Primary energy savings in desiccant and evaporative cooling-assisted 100% outdoor air system combined with a fuel cell

    International Nuclear Information System (INIS)

    Kim, Min-Hwi; Dong, Hae-Won; Park, Joon-Young; Jeong, Jae-Weon

    2016-01-01

    Highlights: • A LD-IDECOAS integrated with a PEMFC was proposed. • A pilot system was installed and tested during cooling operation. • The proposed system powered by the PEMFC saved 21% of the primary energy consumption during cooling. - Abstract: The main purpose of this study involved investigating the primary energy saving potential of a liquid desiccant and evaporative cooling-assisted 100% outdoor air system (LD-IDECOAS) integrated with a proton exchange membrane fuel cell (PEMFC). During the cooling season, the heat produced by the PEMFC was used to regenerate a weak desiccant solution, and the electricity generated was used to operate the LD-IDECOAS. A pilot LD-IDECOAS powered by a PEMFC was installed and operated in an office space to experimentally verify the annual operating energy savings of the proposed system. The findings indicated that the heat reclaimed from the PEMFC saved 42% of the desiccant solution regenerating energy when compared to that in the case of a conventional gas-fired water heater. The results also suggested that the LD-IDECOAS combined with a PEMFC consumed 21% less primary energy when compared with that of a system powered by grid electricity and a conventional gas-fired water heater.

  9. Nuclear power enterprise tax planning strategy in the background of reform

    International Nuclear Information System (INIS)

    Wu Yimin

    2012-01-01

    The success of tax planning can be converted into enterprise's productivity, tax planning strategy can maximize the desired effects and bring out its full play to tax planning. Taking new round of tax reform in 12th five-year-plan and the reformation of professional groups as the background, the author detailedly conceived a frame of corporate tax planning strategy for nuclear power enterprises of China National Nuclear Corporation at the forefront of reformation from an all-round comprehensive view and multi-angle stand. (author)

  10. 12 CFR 561.43 - Savings association.

    Science.gov (United States)

    2010-01-01

    ..., chartered under section 5 of the Act, or a building and loan, savings and loan, or homestead association, or... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Savings association. 561.43 Section 561.43... AFFECTING ALL SAVINGS ASSOCIATIONS § 561.43 Savings association. The term savings association means a...

  11. A Single-Degree-of-Freedom Energy Optimization Strategy for Power-Split Hybrid Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Chaoying Xia

    2017-07-01

    Full Text Available This paper presents a single-degree-of-freedom energy optimization strategy to solve the energy management problem existing in power-split hybrid electric vehicles (HEVs. The proposed strategy is based on a quadratic performance index, which is innovatively designed to simultaneously restrict the fluctuation of battery state of charge (SOC and reduce fuel consumption. An extended quadratic optimal control problem is formulated by approximating the fuel consumption rate as a quadratic polynomial of engine power. The approximated optimal control law is obtained by utilizing the solution properties of the Riccati equation and adjoint equation. It is easy to implement in real-time and the engineering significance is explained in details. In order to validate the effectiveness of the proposed strategy, the forward-facing vehicle simulation model is established based on the ADVISOR software (Version 2002, National Renewable Energy Laboratory, Golden, CO, USA. The simulation results show that there is only a little fuel consumption difference between the proposed strategy and the Pontryagin’s minimum principle (PMP-based global optimal strategy, and the proposed strategy also exhibits good adaptability under different initial battery SOC, cargo mass and road slope conditions.

  12. Savings Behavior and Satisfaction with Savings: A Comparison of Low- and High-Income Groups.

    Science.gov (United States)

    Davis, Elizabeth P.; Schumm, Walter R.

    1987-01-01

    Data on 1,739 married couples from 13 states were analyzed. Associations between satisfaction with savings and level of savings with measures of motivation to save, motivations to spend, and family resources were found to differ substantially between low- and high-income couples. (Author/CH)

  13. A Power System Optimal Dispatch Strategy Considering the Flow of Carbon Emissions and Large Consumers

    Directory of Open Access Journals (Sweden)

    Jun Yang

    2015-08-01

    Full Text Available The carbon emissions trading market and direct power purchases by large consumers are two promising directions of power system development. To trace the carbon emission flow in the power grid, the theory of carbon emission flow is improved by allocating power loss to the load side. Based on the improved carbon emission flow theory, an optimal dispatch model is proposed to optimize the cost of both large consumers and the power grid, which will benefit from the carbon emissions trading market. Moreover, to better simulate reality, the direct purchase of power by large consumers is also considered in this paper. The OPF (optimal power flow method is applied to solve the problem. To evaluate our proposed optimal dispatch strategy, an IEEE 30-bus system is used to test the performance. The effects of the price of carbon emissions and the price of electricity from normal generators and low-carbon generators with regards to the optimal dispatch are analyzed. The simulation results indicate that the proposed strategy can significantly reduce both the operation cost of the power grid and the power utilization cost of large consumers.

  14. Piloting a Savings-Led Microfinance Intervention with Women Engaging in Sex Work in Mongolia: Further Innovation for HIV Risk Reduction

    Science.gov (United States)

    Tsai, Laura Cordisco; Witte, Susan S.; Aira, Toivgoo; Altantsetseg, Batsukh; Riedel, Marion

    2014-01-01

    This paper describes a pilot study testing the feasibility of an innovative savings-led microfinance intervention in increasing the economic empowerment and reducing the sexual risk behavior of women engaging in sex work in Mongolia. Women’s economic vulnerability may increase their risk for HIV by compromising their ability to negotiate safer sex with partners and heightening the likelihood they will exchange sex for survival. Microfinance has been considered a potentially powerful structural HIV prevention strategy with women conducting sex work, as diversification of income sources may increase women’s capacity to negotiate safer transactional sex. With 50% of all reported female HIV cases in Mongolia detected among women engaging in sex work, direct prevention intervention with women conducting sex work represents an opportunity to prevent a potentially rapid increase in HIV infection in urban Mongolia. The piloted intervention consisted of a matched savings program in which matched savings could be used for business development or vocational education, combined with financial literacy and business development training for women engaging in sex work. Results of the pilot demonstrate participants’ increased confidence in their ability to manage finances, greater hope for pursuing vocational goals, moderate knowledge gains regarding financial literacy, and an initial transition from sex work to alternative income generation for five out of nine participants. The pilot findings highlight the potential for such an intervention and the need for a clinical trial testing the efficacy of savings-led microfinance programs in reducing HIV risk for women engaging in sex work in Mongolia. PMID:24900163

  15. Piloting a Savings-Led Microfinance Intervention with Women Engaging in Sex Work in Mongolia: Further Innovation for HIV Risk Reduction.

    Science.gov (United States)

    Tsai, Laura Cordisco; Witte, Susan S; Aira, Toivgoo; Altantsetseg, Batsukh; Riedel, Marion

    2011-12-30

    This paper describes a pilot study testing the feasibility of an innovative savings-led microfinance intervention in increasing the economic empowerment and reducing the sexual risk behavior of women engaging in sex work in Mongolia. Women's economic vulnerability may increase their risk for HIV by compromising their ability to negotiate safer sex with partners and heightening the likelihood they will exchange sex for survival. Microfinance has been considered a potentially powerful structural HIV prevention strategy with women conducting sex work, as diversification of income sources may increase women's capacity to negotiate safer transactional sex. With 50% of all reported female HIV cases in Mongolia detected among women engaging in sex work, direct prevention intervention with women conducting sex work represents an opportunity to prevent a potentially rapid increase in HIV infection in urban Mongolia. The piloted intervention consisted of a matched savings program in which matched savings could be used for business development or vocational education, combined with financial literacy and business development training for women engaging in sex work. Results of the pilot demonstrate participants' increased confidence in their ability to manage finances, greater hope for pursuing vocational goals, moderate knowledge gains regarding financial literacy, and an initial transition from sex work to alternative income generation for five out of nine participants. The pilot findings highlight the potential for such an intervention and the need for a clinical trial testing the efficacy of savings-led microfinance programs in reducing HIV risk for women engaging in sex work in Mongolia.

  16. Using the noninformative families in family-based association tests : A powerful new testing strategy

    NARCIS (Netherlands)

    Lange, C; DeMeo, D; Silverman, EK; Weiss, ST; Laird, NM

    2003-01-01

    For genetic association studies with multiple phenotypes, we propose a new strategy for multiple testing with family-based association tests (FBATs). The strategy increases the power by both using all available family data and reducing the number of hypotheses tested while being robust against

  17. 31 CFR 359.35 - May I purchase definitive Series I savings bonds through a payroll savings plan?

    Science.gov (United States)

    2010-07-01

    ... savings bonds through a payroll savings plan? 359.35 Section 359.35 Money and Finance: Treasury... May I purchase definitive Series I savings bonds through a payroll savings plan? You may purchase definitive bonds through deductions from your pay if your employer maintains a payroll savings plan. An...

  18. DSM energy saving pilot project report. Furniture Plant Teika, Riga, Latvia

    International Nuclear Information System (INIS)

    Ananevski, V.; Kalejs, M.; Hercogs, J.; Blumbergs, U.

    1995-07-01

    The purpose of this pilot project was to carry out energy audit into the furniture plant TEIKA and energy saving measures. Another aim was to transfer the Danish know how and experience obtained through the Danish effort in Latvian industries consumers. Therefore great attention is paid to energy mapping in order to show possibilities of the Danish methodisms. This report is a part of the Joint Latvian - Danish Project Demand Side Management and Energy Saving. It is a results of collaborative efforts between a Latvian team, consisting of the specialists from Latvenergo and on the other hand a Danish team, which was represented by the Danish Power Consult company NESA. (EG)

  19. Community based social marketing for implementation of energy saving targets at local level

    Directory of Open Access Journals (Sweden)

    Dalia Streimikiene

    2015-05-01

    Full Text Available Energy saving and greenhouse gas (GHG emission reduction policies at local level need to be investigated and new tools for climate change mitigation are necessary seeking to achieve GHG emission targets in Lithuania. Most Lithuanian municipalities have signed Covenant of Mayors and have prepared local energy action plans. However, all these plans include just energy saving measures on supply side and renovation of buildings. Nevertheless, the significant energy savings and GHG emission reductions can be achieved through behavioural changes. The aim of the paper is to apply community based social marketing approach in assessment of achievable energy saving and GHG emission reduction targets set by local energy action plans. The paper presents the results of case study implemented in Kaunas region municipality. The case study was conducted by creating focus groups and applying two scenarios: baseline or doing nothing and climate change mitigation scenario including intervention measures. The results of case study revealed that the total energy consumption reduction target set in Sustainable energy development strategy of Kaunas region county - 11% - can be achieved by combining results of energy consumption reduction in both focus groups. The survey conducted after study finalization revealed that respondents were provided with a lot of additional knowledge during the study and achieved real money savings. The major barriers of energy savings in households are related with the lack of information on energy savings and GHG emission reduction.

  20. Diversity Strategies for Nuclear Power Plant Instrumentation and Control Systems

    International Nuclear Information System (INIS)

    Wood, Richard Thomas; Belles, Randy; Cetiner, Mustafa Sacit; Holcomb, David Eugene; Korsah, Kofi; Loebl, Andy; Mays, Gary T.; Muhlheim, Michael David; Mullens, James Allen; Poore, Willis P. III; Qualls, A.L.; Wilson, Thomas L.; Waterman, Michael E.

    2010-01-01

    This report presents the technical basis for establishing acceptable mitigating strategies that resolve diversity and defense-in-depth (D3) assessment findings and conform to U.S. Nuclear Regulatory Commission (NRC) requirements. The research approach employed to establish appropriate diversity strategies involves investigation of available documentation on D3 methods and experience from nuclear power and nonnuclear industries, capture of expert knowledge and lessons learned, determination of best practices, and assessment of the nature of common-cause failures (CCFs) and compensating diversity attributes. The research described in this report does not provide guidance on how to determine the need for diversity in a safety system to mitigate the consequences of potential CCFs. Rather, the scope of this report provides guidance to the staff and nuclear industry after a licensee or applicant has performed a D3 assessment per NUREG/CR-6303 and determined that diversity in a safety system is needed for mitigating the consequences of potential CCFs identified in the evaluation of the safety system design features. Succinctly, the purpose of the research described in this report was to answer the question, 'If diversity is required in a safety system to mitigate the consequences of potential CCFs, how much diversity is enough?' The principal results of this research effort have identified and developed diversity strategies, which consist of combinations of diversity attributes and their associated criteria. Technology, which corresponds to design diversity, is chosen as the principal system characteristic by which diversity criteria are grouped to form strategies. The rationale for this classification framework involves consideration of the profound impact that technology-focused design diversity provides. Consequently, the diversity usage classification scheme involves three families of strategies: (1) different technologies, (2) different approaches within the same