WorldWideScience

Sample records for power plants impacts

  1. Environmental impact due to nuclear power plants

    International Nuclear Information System (INIS)

    Kellermann, O.; Balfanz, H.P.

    1975-01-01

    The environmental impact due to nuclear power plants is smaller than that due to fossil-fired power plants. The risks of the nuclear power plant operation are determined by the quantity and the probability of the release of radioactive materials. According to the value, the risks of normal operation can be compared to the accident risks. An attempt should be made to effectively reduce the remaining risk at unfavourable sites with the emphasis on accidents with larger effects than design basis accidents. (orig./LH) [de

  2. Regional economic impacts of nuclear power plants

    International Nuclear Information System (INIS)

    Isard, W.; Reiner, T.; Van Zele, R.; Stratham, J.

    1976-08-01

    This study of economic and social impacts of nuclear power facilities compares a nuclear energy center (NEC) consisting of three surrogate sites in Ocean County, New Jersey with nuclear facilities dispersed in the Pennsylvania - New Jersey - Maryland area. The NEC studied in this report is assumed to contain 20 reactors of 1200 MW(e) each, for a total NEC capacity of 24,000 MW(e). Following the Introductory chapter, Chapter II discusses briefly the methodological basis for estimating impacts. This part of the analysis only considers impacts of wages and salaries and not purchase of construction materials within the region. Chapters III and IV, respectively, set forth the scenarios of an NEC at each of three sites in Ocean County, N.J. and of a pattern of dispersed nuclear power plants of total equivalent generating capacity. In each case, the economic impacts (employment and income) are calculated, emphasizing the regional effects. In Chapter V these impacts are compared and some more general conclusions are reported. A more detailed analysis of the consequences of the construction of a nuclear power plant is given in Chapter VI. An interindustry (input-output) study, which uses rather finely disaggregated data to estimate the impacts of a prototype plant that might be constructed either as a component of the dispersed scenario or as part of an NEC, is given. Some concluding remarks are given in Chapter VII, and policy questions are emphasized

  3. Southpoint power plant final environmental impact statement

    International Nuclear Information System (INIS)

    1999-01-01

    This document is the Final Environmental Impact Statement (FEIS) for a proposed lease of acreage on the Fort Mojave Indian Reservation in Mohave County, Arizona for development of a natural gas fired 500 megawatt combined cycle power plant. The Bureau of Indian Affairs (BIA) serves as the federal lead agency and the Fort Mojave Indian Tribe (FMIT) and the Western Area Power Administration (WAPA) are cooperating agencies for the EIS process. The purpose of this document is to provide information to the public and to interested public agencies regarding the environmental consequences of the approval of a long-term lease for the construction and operation of the proposed Southpoint power plant. The FEIS, prepared by Hallock/Gross, Inc. under the direction of the BIA and in cooperation with the FMIT and WAPA, addresses the comparative analysis of alternatives and evaluates the environmental consequences of such alternatives on various resources and addresses public comments. A number of technical reports were used in the preparation of the Draft EIS and FEIS and are available for review as Appendices to this document under separate cover that can be reviewed at the BIA offices which are listed

  4. Evaluation of Visual and Landscape Impacts of Nuclear Power Plants

    International Nuclear Information System (INIS)

    Algohary, S.A.

    2007-01-01

    The nuclear power plant is a huge structure, and in terms of both size and function may result in an unacceptable visual conflict in both local and wider environment. Also, it has major implications in terms of physical, social, economic, environmental and impact on people. The environmental impacts include the visual and landscape aspects of these plants. This paper outlines the main general ideas of the architecture aspects of nuclear power plants, nuclear reactors. Also, it discusses the site selection considerations: Finally, it introduces an approach for the evaluation of visual and landscape impacts of nuclear power plants

  5. Airplane impact on nuclear power plants

    International Nuclear Information System (INIS)

    Eibl, J.

    2003-01-01

    A short report on investigations of nuclear power plants under airplane attack is given. It concerns the modeling of planes with regard to mass and stiffness, the relevant plane velocity and finally the determination of load-time functions. The necessary analysis of the concrete containment structure is shortly addressed. Finally a proposal for a structure to keep planes from such building structures is discussed. (author)

  6. Environmental impact assessment of coal power plants in operation

    OpenAIRE

    Bartan Ayfer; Kucukali Serhat; Ar Irfan

    2017-01-01

    Coal power plants constitute an important component of the energy mix in many countries. However, coal power plants can cause several environmental risks such as: climate change and biodiversity loss. In this study, a tool has been proposed to calculate the environmental impact of a coal-fired thermal power plant in operation by using multi-criteria scoring and fuzzy logic method. We take into account the following environmental parameters in our tool: CO, SO2, NOx, particulate matter, fly as...

  7. Environmental impacts of coal and nuclear power plants

    International Nuclear Information System (INIS)

    Carvalho, W.B.D. de; Souza, J.A.M. de

    1981-01-01

    The present work analyses the environmental impacts of coal and nuclear power plants. A comparison is made on a common basis considering the various activities involving the complete fuel cycle for both cases. (Author) [pt

  8. Unique ecological impacts associated with offshore floating nuclear power plants

    International Nuclear Information System (INIS)

    Adams, S.M.; McLean, R.B.

    1979-01-01

    The ecological impacts that could occur as a result of site construction and operation of an offshore floating nuclear power plant are identified by comparing the principal ecological features associated with offshore siting with those associated with the siting of onshore estuarine plants. In general, the ecological impacts of offshore nuclear plants should be relatively smaller than those of estuarine plants. Possible factors that could increase the relative impacts of offshore plants are high frequency of contact with schools of fish, siting near inlets to estuaries or other ecologically important areas, and the persistence of halogen residuals. Identifying the potential ecological impacts associated with the siting of offshore plants permits the development of various monitoring programs and measures to minimize these impacts

  9. Environmental impacts of nuclear and coal-fired power plants

    International Nuclear Information System (INIS)

    Horyna, J.; Horynova, H.

    1984-01-01

    The current situation in the development of nuclear power in the world and in Czechoslovakia is briefly outlined and the possibilities are discussed of alternative energy resources. The environmental impact is described of conventional power plants firing coal; sulphur and nitrogen oxides are mentioned and their environmental impacts shown. Their quantities and the quantities of other gaseous, liquid and soid wastes produced by coal power plants are given. Annual estimates are presented of radioactive material emissions; trace amount emissions of toxic metals and their ecological risks are shown. Concern over the increasing concentration of CO 2 in the atmosphere is voiced. For nuclear power plants, the amount of radionuclides in stack emission and of those released into water flows is tabulated. Their effect on the aqueous ecosystem is characterized as is thermal pollution of water flows and the environmental impact of cooling towers. Other factors are also mentioned, such as the increased industrial land use, the effect of high voltage transmission lines and aesthetic effects. The conclusion is arrived at that the construction of nuclear power plants will eliminate the adverse environmental impact of emissions while the other impacts of the two types of power plants are comparable. (A.K.)

  10. Environmental impact assessment of coal power plants in operation

    Directory of Open Access Journals (Sweden)

    Bartan Ayfer

    2017-01-01

    Full Text Available Coal power plants constitute an important component of the energy mix in many countries. However, coal power plants can cause several environmental risks such as: climate change and biodiversity loss. In this study, a tool has been proposed to calculate the environmental impact of a coal-fired thermal power plant in operation by using multi-criteria scoring and fuzzy logic method. We take into account the following environmental parameters in our tool: CO, SO2, NOx, particulate matter, fly ash, bottom ash, the cooling water intake impact on aquatic biota, and the thermal pollution. In the proposed tool, the boundaries of the fuzzy logic membership functions were established taking into account the threshold values of the environmental parameters which were defined in the environmental legislation. Scoring of these environmental parameters were done with the statistical analysis of the environmental monitoring data of the power plant and by using the documented evidences that were obtained during the site visits. The proposed method estimates each environmental impact factor level separately and then aggregates them by calculating the Environmental Impact Score (EIS. The proposed method uses environmental monitoring data and documented evidence instead of using simulation models. The proposed method has been applied to the 4 coal-fired power plants that have been operation in Turkey. The Environmental Impact Score was obtained for each power plant and their environmental performances were compared. It is expected that those environmental impact assessments will contribute to the decision-making process for environmental investments to those plants. The main advantage of the proposed method is its flexibility and ease of use.

  11. Environmental impact assessment of coal power plants in operation

    Science.gov (United States)

    Bartan, Ayfer; Kucukali, Serhat; Ar, Irfan

    2017-11-01

    Coal power plants constitute an important component of the energy mix in many countries. However, coal power plants can cause several environmental risks such as: climate change and biodiversity loss. In this study, a tool has been proposed to calculate the environmental impact of a coal-fired thermal power plant in operation by using multi-criteria scoring and fuzzy logic method. We take into account the following environmental parameters in our tool: CO, SO2, NOx, particulate matter, fly ash, bottom ash, the cooling water intake impact on aquatic biota, and the thermal pollution. In the proposed tool, the boundaries of the fuzzy logic membership functions were established taking into account the threshold values of the environmental parameters which were defined in the environmental legislation. Scoring of these environmental parameters were done with the statistical analysis of the environmental monitoring data of the power plant and by using the documented evidences that were obtained during the site visits. The proposed method estimates each environmental impact factor level separately and then aggregates them by calculating the Environmental Impact Score (EIS). The proposed method uses environmental monitoring data and documented evidence instead of using simulation models. The proposed method has been applied to the 4 coal-fired power plants that have been operation in Turkey. The Environmental Impact Score was obtained for each power plant and their environmental performances were compared. It is expected that those environmental impact assessments will contribute to the decision-making process for environmental investments to those plants. The main advantage of the proposed method is its flexibility and ease of use.

  12. Impact loads on nuclear power plant structures

    International Nuclear Information System (INIS)

    Riera, J.D.

    1993-01-01

    The first step in evaluation of a NPP design for protection against impact loading, is to identify those events that may be credible for a particular site. In connection with external, man-made events IAEA Safety Series No.50-SG-S5 provides a methodology for selecting the events that need to be considered. This presentation deals with modelling of interface forces in projectile impact against unyielding structures, vibrations induced by impact, penetration, scabbing and perforation effects

  13. Quantitative assessment of aquatic impacts of power plants

    Energy Technology Data Exchange (ETDEWEB)

    McKenzie, D.H.; Arnold, E.M.; Skalski, J.R.; Fickeisen, D.H.; Baker, K.S.

    1979-08-01

    Progress is reported in a continuing study of the design and analysis of aquatic environmental monitoring programs for assessing the impacts of nuclear power plants. Analysis of data from Calvert Cliffs, Pilgrim, and San Onofre nuclear power plants confirmed the generic applicability of the control-treatment pairing design suggested by McKenzie et al. (1977). Substantial progress was made on the simulation model evaluation task. A process notebook was compiled in which each model equation was translated into a standardized notation. Individual model testing and evaluating was started. The Aquatic Generalized Environmental Impact Simulator (AGEIS) was developed and will be tested using data from Lake Keowee, South Carolina. Further work is required to test the various models and perfect AGEIS for impact analyses at actual power plant sites. Efforts on the hydrologic modeling task resulted in a compendium of models commonly applied to nuclear power plants and the application of two well-received hydrodynamic models to data from the Surry Nuclear Power Plant in Virginia. Conclusions from the study of these models indicate that slight inaccuracies of boundary data have little influence on mass conservation and accurate bathymetry data are necessary for conservation of mass through the model calculations. The hydrologic modeling task provides valuable reference information for model users and monitoring program designers.

  14. Quantitative assessment of aquatic impacts of power plants

    International Nuclear Information System (INIS)

    McKenzie, D.H.; Arnold, E.M.; Skalski, J.R.; Fickeisen, D.H.; Baker, K.S.

    1979-08-01

    Progress is reported in a continuing study of the design and analysis of aquatic environmental monitoring programs for assessing the impacts of nuclear power plants. Analysis of data from Calvert Cliffs, Pilgrim, and San Onofre nuclear power plants confirmed the generic applicability of the control-treatment pairing design suggested by McKenzie et al. (1977). Substantial progress was made on the simulation model evaluation task. A process notebook was compiled in which each model equation was translated into a standardized notation. Individual model testing and evaluating was started. The Aquatic Generalized Environmental Impact Simulator (AGEIS) was developed and will be tested using data from Lake Keowee, South Carolina. Further work is required to test the various models and perfect AGEIS for impact analyses at actual power plant sites. Efforts on the hydrologic modeling task resulted in a compendium of models commonly applied to nuclear power plants and the application of two well-received hydrodynamic models to data from the Surry Nuclear Power Plant in Virginia. Conclusions from the study of these models indicate that slight inaccuracies of boundary data have little influence on mass conservation and accurate bathymetry data are necessary for conservation of mass through the model calculations. The hydrologic modeling task provides valuable reference information for model users and monitoring program designers

  15. Impact of power plant KRSKO on the environment

    International Nuclear Information System (INIS)

    Hak, Nena; Lulic, Stipe

    1993-01-01

    The Sava river is among the largest rivers in the Republic of Croatia. It drains 95.000 square kilometers before meeting the Danube River. The Sava river and its surroundings we being exploited in agriculture, forestry, power generation (one nuclear power plant and several thermal power plants), oil transportation, gravel extraction and recreation. At last, the Sava River is the major source of fresh water for industry and population. Different authorized institutions from the Republic of Slovenia and the Republic of Croatia are included in programs of nonradiological and radiological monitoring of Nuclear Power Plant Krsko (NPPK). Quarterly, the institutions from the Republic of Croatia, NPP Krsko and the Ministry of Energy of the Republic of Croatia, submit public information in the Republic of Croatia about NPP Krsko operation and its environmental impact

  16. Health impacts of power-exporting plants in northern Mexico

    International Nuclear Information System (INIS)

    Blackman, Allen; Chandru, Santosh; Mendoza-Domínguez, Alberto; Russell, A.G.

    2012-01-01

    In the past two decades, rapid population and economic growth on the U.S.–Mexico border has spurred a dramatic increase in electricity demand. In response, American energy multinationals have built power plants just south of the border that export most of their electricity to the U.S. This development has stirred considerable controversy because these plants effectively skirt U.S. air pollution regulations in a severely degraded international airshed. Yet to our knowledge, this concern has not been subjected to rigorous scrutiny. This paper uses a suite of air dispersion, health impacts, and valuation models to assess the human health damages in the U.S. and Mexico caused by air emissions from two power-exporting plants in Mexicali, Baja California. We find that these emissions have limited but nontrivial health impacts, mostly by exacerbating particulate pollution in the U.S., and we value these damages at more than half a million dollars per year. These findings demonstrate that power-exporting plants can have cross-border health effects and bolster the case for systematically evaluating their environmental impacts. - Highlights: ► We estimate the health effects of emissions from Mexican electric power plants exporting to the U.S. ► The plants have limited but nontrivial effects, mostly from particulate pollution in the U.S. ► We value these damages at more than half a million dollars per year. ► Hence, power-exporting plants can have significant cross-border health effects.

  17. Environmental impacts of power plants and transmission lines in power system planning

    International Nuclear Information System (INIS)

    Miracapillo, C.; Moreschini, G.; Rome Univ. 'La Sapienza'

    1992-01-01

    This paper deals with a criterion to assess the environmental impacts of power plants and transmission lines in power system planning. First, the effects of hydro-plants, thermal plants and transmission lines are reviewed. Then, a number of methods for the evaluation of the environmental impacts of civil and industrial plants are described. A new criterion is proposed to introduce the evaluation of the environmental impact and related costs into methods for power system planning. Finally, the criterion is applied to a simple case

  18. Aircraft impact on nuclear power plants concrete structures

    International Nuclear Information System (INIS)

    Coombs, R.F.; Barbosa, L.C.B.; Santos, S.H.C.

    1980-01-01

    A summary about the procedures for the analysis of aircraft on concrete structures, aiming to emphasize the aspects related to the nuclear power plants safety, is presented. The impact force is determined by the Riera model. The effect of this impact force on the concrete structures is presented, showing the advantages to use nonlinear behaviour in the concrete submitted to short loads. The simplifications used are shown through a verification example of the nuclear reactor concrete shielding. (E.G.) [pt

  19. Evaluating the impacts of power plant emissions in Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Villegas, M.T.; Tzintzun Cervantes, M.G.; Iniestra Gomez, R.; Garibay Bravo, V.; Zuk, M.; Rojas Bracho, L.; Fernandez Bremautz, A. [Direccion de Investigacion sobre Calidad del Aire, Inst. Nacional de Ecologia (Mexico)

    2004-07-01

    Mexican electricity generation has proven to be a large source of air pollution nationwide. According to the Energy Secretariat, electricity generation in Mexico accounts for 68% of SO{sub 2} emissions, 24% of PM{sub 10} emissions and 20% of NO{sub x} emissions nationwide. The country's total effective installed capacity is 42,067 MW, of which 67% corresponds to thermoelectric power plants. Heavy fuel oil, known as 'combustoleo', is used in many thermoelectric plants primarily for regular operation. The typical sulphur content of 'combustoleo' is approximately 2.5 to 4%. As a first step to determine the potential impacts of Mexican power plants on regional air pollution and health, we conducted a case study on the Adolfo Lopez Mateos power plant, located in the town of Tuxpan in the eastern state of Veracruz. The plant is located on the northern coast of the Gulf of Mexico; therefore greatly influenced by the weather of the region. We used the CALPUFF Lagrangian puff model (Earth Tech, Concord, MA) to simulate the dispersion of SO{sub 2}, NO{sub x} and primary PM{sub 10} emissions from the power plant stacks and the formation of secondary particulate matter. We considered a 120km x 120km grid, with a resolution of 2km x 2km and height of 2500 km. This area comprises approximately 791,000 inhabitants, including rural and urban populations. (orig.)

  20. Thermal impact assessment of multi power plant operations on estuaries

    International Nuclear Information System (INIS)

    Eraslan, A.H.; Kim, K.H.; Harris, J.L.

    1977-01-01

    The assessment of the thermal impact of multi power plant operations on large estuaries requires careful consideration of the problems associated with: re-entrainment, re-circulation, thermal interaction, delay in the attainment of thermal equilibrium state, and uncertainty in specifying open boundaries and open boundary conditions of the regions, which are critically important in the analysis of the thermal conditions in receiving water bodies with tidal dominated, periodically reversing flow conditions. The results of an extensive study in the Hudson River at Indian Point, 42 miles upstream of the ocean end at the Battery, concluded that the tidal-transient, multi-dimensional discrete-element (UTA) thermal transport models (ESTONE, FLOTWO, TMPTWO computer codes) and the near-field far-field zone-matching methodology can be employed with a high degree of reliability in the assessment of the thermal impact of multi power plant operations on tidal dominated estuaries

  1. Year 2000 problem impact on nuclear power plants

    International Nuclear Information System (INIS)

    Mauck, J.L.

    1998-01-01

    US Nuclear Regulatory commission began consideration of Year 2000 problem in nuclear power plants in 1996. It was found that no Year 2000 problem exists in safety related (reactor protection) instrumentation and control systems. Other important but not safety related systems needed for safe operation are impacted, namely security, emergency response data collection, radiation monitoring and control, surveillance tracking, control of feedwater, control rods, turbine as well as externals (communication, parts supply)

  2. Impact of Negative Sequence Current Injection by Wind Power Plants

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay; Göksu, Ömer; Teodorescu, Remus

    2013-01-01

    This paper presents an analysis of the impact from negative sequence current injection by wind power plants in power systems under steady-state and short-term unbalanced conditions, including faults. The separate positive and negative sequence current control capability of the grid-side converters...... of full scale converter type wind turbines may be utilized to alter voltage imbalance at the point of connection and further into the grid, in turn changing the resultant negative sequence current flow in the grid. The effects of such control actions have been analyzed and discussed through theoretical...

  3. Sensitivity of nuclear power plant structural response to aircraft impact

    International Nuclear Information System (INIS)

    Buchhardt, F.; Magiera, G.; Matthees, W.; Weber, M.

    1984-01-01

    In this paper a sensitivity study for aircraft impact is performed concerning the excitation of internal components, with particular regard to nonlinear structural material behaviour in the impact area. The nonlinear material values are varied within the bandwidth of suitable material strength, depending on local stiffness pre-calculations. The analyses are then performed on a globally discretized three-dimensional finite element model of a nuclear power plant, using a relatively fine mesh. For specified nodal points results are evaluated by comparing their response spectra. (Author) [pt

  4. Evaluation of the feasibility, economic impact, and effectiveness of underground nuclear power plants. Final technical report

    International Nuclear Information System (INIS)

    1978-05-01

    Information on underground nuclear power plants is presented concerning underground nuclear power plant concepts; public health impacts; technical feasibility of underground concepts; economic impacts of underground construction; and evaluation of related issues

  5. The environmental impact of the Ignalina nuclear power plant

    International Nuclear Information System (INIS)

    Drizius, R.; Jasiulionis, R.; Marciulioniene, D.

    1991-01-01

    In the course of design and initial operation of the nuclear power plant in Ignalina several research institutes of the Lithuanian Academy of Sciences performed monitoring measurements in the surroundings and accumulated data on the natural situation with a special interest in the environmental impact of the plant. The ecosystem of lake Druksiai as the cooling pond of the plant was expected to be influenced most. At present sufficient results have been accumulated to conclude a shift from natural equilibrium of the lake ecosystem in spite of the absence of any specific cases of severing the present nature-protecting legislation. At present the lake is an example of a transient environmental system because of the high inertia in most of the natural processes and because certain natural components are known to accumlate the products of release and to transform them. (author)

  6. Impacts of TMDLs on coal-fired power plants.

    Energy Technology Data Exchange (ETDEWEB)

    Veil, J. A.; Environmental Science Division

    2010-04-30

    The Clean Water Act (CWA) includes as one of its goals restoration and maintenance of the chemical, physical, and biological integrity of the Nation's waters. The CWA established various programs to accomplish that goal. Among the programs is a requirement for states to establish water quality standards that will allow protection of the designated uses assigned to each water body. Once those standards are set, state agencies must sample the water bodies to determine if water quality requirements are being met. For those water bodies that are not achieving the desired water quality, the state agencies are expected to develop total maximum daily loads (TMDLs) that outline the maximum amount of each pollutant that can be discharged to the water body and still maintain acceptable water quality. The total load is then allocated to the existing point and nonpoint sources, with some allocation held in reserve as a margin of safety. Many states have already developed and implemented TMDLs for individual water bodies or regional areas. New and revised TMDLs are anticipated, however, as federal and state regulators continue their examination of water quality across the United States and the need for new or revised standards. This report was funded by the U.S. Department of Energy's (DOE's) National Energy Technology Laboratory (NETL) Existing Plants Research Program, which has an energy-water research effort that focuses on water use at power plants. This study complements its overall research effort by evaluating water issues that could impact power plants. One of the program missions of the DOE's NETL is to develop innovative environmental control technologies that will enable full use of the Nation's vast coal reserves, while at the same time allowing the current fleet of coal-fired power plants to comply with existing and emerging environmental regulations. Some of the parameters for which TMDLs are being developed are components in discharges

  7. Plant control impact on IFR power plant passive safety response

    International Nuclear Information System (INIS)

    Vilim, R.B.

    1993-01-01

    A method is described for optimizing the closed-loop plant control strategy with respect to safety margins sustained in the unprotected upset response of a liquid metal reactor. The optimization is performed subject to the normal requirements for reactor startup, load change and compensation for reactivity changes over the cycle. The method provides a formal approach to the process of exploiting the innate self-regulating property of a metal fueled reactor to make it less dependent on operator action and less vulnerable to automatic control system fault and/or operator error

  8. Economic Impact of Nuclear Power Plant in The Operational

    International Nuclear Information System (INIS)

    Sriyana

    2004-01-01

    Study on economic impact of nuclear power plant in the operational stage, in Madura has been conducted. The object of the study is SMART technology which is coupled with desalination installation. The power capacity is 2 x 100 M We and the water production capacity is 4 x 10,000 m 3 /day. This technology has been developed by Korea, but until recently there is no units in construction or operation. Input-Output analysis model is applied as the methodology of this study. Economic sector is aggregated from 56 x 56 to 10 x 10. This aggregation is meant to reduce the uncertainty in long term projection. This study conclude that : (1) In the operational stage SMART Nuclear Power Desalination will give an output to local economic about Rp 908.12 billion per year. (2) Electricity and water production will provide output direct impact to Madura about Rp. 1,234 trillion and will give direct impact to Regional Product Domestic Bruto (PDRB) about Rp. 138.7 billion. (3) Output impact to the electricity sector and fresh water sector is about 5.37% and 1.57% compared to PDRB 2018. (author)

  9. Socio/economic/ecological impacts of nuclear power plants

    International Nuclear Information System (INIS)

    Golden, J.; Watson, J.

    1975-01-01

    A nuclear facility has both radiological and non-radiological effects on the environment. To minimize radiological effects, limits are set on releases of radioactive materials that will cause either direct or indirect exposure (such as the food chain). Exposure pathways for man and other organisms are described with comparisons of typical calculated doses and design objective doses. Non-radiological impacts of nuclear plants are classified as ecological-physical and socio/economic considerations, which include eighteen areas affected during each phase of the nuclear facility cycle. The ecological-physical environment is impacted in the areas of hydrology, terrestrial and aquatic ecology, and air and water quality. The socio-economic environment is impacted in areas of land use, tax base, employment, economic stimulus, relocation, lifestyle, demand for service, aesthetics, and power needs. Case studies of large construction projects are described in the appendix

  10. LOCAL IMPACTS OF MERCURY EMISSIONS FROM COAL FIRED POWER PLANTS.

    Energy Technology Data Exchange (ETDEWEB)

    SULLIVAN, T.M.; BOWERMAN, B.; ADAMS, J.; LIPFERT, D.D.; MORRIS, S.M.; BANDO, A.; ET AL.

    2004-03-30

    A thorough quantitative understanding of the processes of mercury emissions, deposition, and translocation through the food chain is currently not available. Complex atmospheric chemistry and dispersion models are required to predict concentration and deposition contributions, and aquatic process models are required to predict effects on fish. There are uncertainties in all of these predictions. Therefore, the most reliable method of understanding impacts of coal-fired power plants on Hg deposition is from empirical data. A review of the literature on mercury deposition around sources including coal-fired power plants found studies covering local mercury concentrations in soil, vegetation, and animals (fish and cows (Lopez et al. 2003)). There is strong evidence of enhanced local deposition within 3 km of the chlor-alkali plants, with elevated soil concentrations and estimated deposition rates of 10 times background. For coal-fired power plants, the data show that atmospheric deposition of Hg may be slightly enhanced. On the scale of a few km, modeling suggests that wet deposition may be increased by a factor of two or three over background. The measured data suggest lower increases of 15% or less. The effects of coal-fired plants seem to be less than 10% of total deposition on a national scale, based on emissions and global modeling. The following summarizes our findings from published reports on the impacts of local deposition. In terms of excesses over background the following increments have been observed within a few km of the plant: (1) local soil concentration Hg increments of 30%-60%, (2) sediment increments of 18-30%, (3) wet deposition increments of 11-12%, and (4) fish Hg increments of about 5-6%, based on an empirical finding that fish concentrations are proportional to the square root of deposition. Important uncertainties include possible reductions of RGM to Hg(0) in power plant plumes and the role of water chemistry in the relationship between Hg

  11. Impact assessment of tornado against nuclear power plant

    International Nuclear Information System (INIS)

    Sato, Daisuke

    2015-01-01

    The impact assessment of tornado against nuclear power plants conforms to the 'Assessment guide for tornado effect on nuclear power plants' stipulated by the Nuclear Regulation Authority. In face of the assessment, important items are the setting of the maximum wind speed considered in design, and the setting of a flying object evaluation model, on the basis of observation results. The Japan Society of Maintenology summarized the verification results of the concept on the setting of tornado design and flying object valuation model, the contents of which are explained here. The following are explained: (1) validity of the setting of tornado design in the Assessment Guide, (2) analysis of synoptic field, (3) study on the regional characteristics of tornado occurrence environmental field by means of the analysis of synoptic field and gust associated index, and (4) setting of tornado design based on the above (1)-(3). Next, on the flying object evaluation model, the authors picked up the Rankine vortex model and Fujita model, and verified the reproducibility of the models using the features of each and the actual state of tornado damage. (A.O.)

  12. Impacts of nuclear power plant developments on community service capacity

    International Nuclear Information System (INIS)

    Krannich, R.S.

    1978-03-01

    With the passage of the National Environmental Policy Act in 1969 a legislative mandate was established to assess ''socioeconomic'' as well as environmental consequences of large-scale development projects. However, the developing literature base in the area of socioeconomics has exhibited a pronounced tendency to stress social and economic pathologies associated with the so-called ''boom town'' syndrome. While boom growth and associated problems do appear to provide relevant conceptualizations of the socioeconomic impacts of energy resource development projects in geographically isolated sectors of the western United States, the argument is presented that such a perspective is generally inappropriate when assessing the consequences of nuclear power plant developments. Survey data on 21 nuclear generating facilities are analyzed in order to provide a comparative perspective on socioeconomic consequences and factors which may influence their relative importance

  13. Assessment of environmental impacts of nuclear power plants

    International Nuclear Information System (INIS)

    Horacek, P.

    1990-01-01

    The effects of normal operation and of accidents are analyzed. It is pointed out that the public is insufficiently informed, which bears anxiety and prejudice. The effective dose equivalents for the population and for the individual, measured during operation of the Bohunice nuclear power plants are listed and compared with those from natural background and from medical applications. The possible radioactive contamination of a large area of agricultural soil is the highest specific risk of nuclear power plant operation. Problems are growing related to spent fuel disposal and eventually to the decommissioning of the power plant itself. (M.D.). 1 tab., 8 refs

  14. Exergy and Environmental Impact Assessment between Solar Powered Gas Turbine and Conventional Gas Turbine Power Plant

    OpenAIRE

    Rajaei, Ali; Barzegar Avval, Hasan; Eslami, Elmira

    2016-01-01

    Recuperator is a heat exchanger that is used in gas turbine power plants to recover energy from outlet hot gases to heat up the air entering the combustion chamber. Similarly, the combustion chamber inlet air can be heated up to temperatures up to 1000 (°C) by solar power tower (SPT) as a renewable and environmentally benign energy source. In this study, comprehensive comparison between these two systems in terms of energy, exergy, and environmental impacts is carried out. Thermodynamic simul...

  15. 78 FR 37325 - License Renewal of Nuclear Power Plants; Generic Environmental Impact Statement and Standard...

    Science.gov (United States)

    2013-06-20

    ... Nuclear Power Plants; Generic Environmental Impact Statement and Standard Review Plans for Environmental... for Nuclear Power Plants, Supplement 1: Operating License Renewal'' (ESRP). The ESRP serves as a guide... published a final rule, ``Revisions to Environmental Review for Renewal of Nuclear Power Plant Operating...

  16. Environmental impacts of nuclear power plants and the tasks of meteorology

    International Nuclear Information System (INIS)

    Rak, J.; Skulec, S.; Tomlain, J.

    1984-01-01

    The system of meteorological service is presented which is part of the nuclear power plant monitoring system. Tasks are described which the meteorological service fulfils in routine nuclear power plant operation and in case of accident. The meteorological service also studies the potential impacts of heat emissions and water effluents on the environment of nuclear power plants. (E.S.)

  17. Financial and ratepayer impacts of nuclear power plant regulatory reform

    International Nuclear Information System (INIS)

    Turpin, A.G.

    1985-01-01

    Three reports - ''The Future Market for Electric Generating Capacity,'' ''Quantitative Analysis of Nuclear Power Plant Licensing Reform,'' and ''Nuclear Rate Increase Study'' are recent studies performed by the Los Alamos National Laboratory that deal with nuclear power. This presents a short summary of these three studies. More detail is given in the reports

  18. Impact of power plants on aquatic systems: a social perspective

    International Nuclear Information System (INIS)

    Coutant, C.C.

    1975-01-01

    Topics discussed are: aquatic effects of thermal electric power stations; legal aspects of water pollution; EPA provisions for levels of thermal discharges to assure protection and propagation of a balanced, indigenous population of shellfish, fish, and wildlife in a body of water; cost benefit analysis of steam electric power effluents; cooling systems and siting of power plants; simulation modeling of population dynamics; and sociological aspects of water pollution

  19. National conference on radiation safety of nuclear power plants and their environmental impacts

    International Nuclear Information System (INIS)

    Moravek, J.

    1989-01-01

    The first national conference on radiation safety of nuclear power plants and their environmental impacts was held in Tale (CS), 12 to 15 October, 1987 with the participation of 201 Czechoslovak specialists representing central authorities, research institutes, institutions of higher education, power plants in operation and under construction, water management and hygiene inspection and some production sectors, specialists from Hungary, Poland and the GDR. The participants heard 110 papers. The conference agenda comprised keynote papers presented in plenary session and five specialist sessions: 1. Radiation control of discharges and their surroundings. 2. Monitoring and evaluation of the radiation situation in nuclear power plants. 3. Equipment for monitoring the nuclear power plant and its environs. 4. Mathematical modelling and assessment of the nuclear power plant radiation environmental impact. 5. Evaluation of sources and of the transport of radioactive materials inside the power plant and the minimization of the nuclear power plant's environmental impact. (Z.M.)

  20. Geothermal power plants principles, applications, case studies and environmental impact

    CERN Document Server

    DiPippo, Ronald

    2008-01-01

    Ron DiPippo, Professor Emeritus at the University of Massachusetts Dartmouth, is a world-regarded geothermal expert. This single resource covers all aspects of the utilization of geothermal energy for power generation from fundamental scientific and engineering principles. The thermodynamic basis for the design of geothermal power plants is at the heart of the book and readers are clearly guided on the process of designing and analysing the key types of geothermal energy conversion systems. Its practical emphasis is enhanced by the use of case studies from real plants that increase the reader'

  1. Intervention analysis of power plant impact on fish populations

    International Nuclear Information System (INIS)

    Madenjian, C.P.

    1984-01-01

    Intervention analysis was applied to 10 yr (years 1973-1982) of field fish abundance data at the D. C. Cook Nuclear Power Plant, southeastern Lake Michigan. Three log-transformed catch series, comprising monthly observations, were examined for each combination of two species (alewife, Alosa pseudoharenga, or yellow perch, Perca flavescens) and gear (trawl or gill net): catch at the plant discharged transect, catch at the reference transect, and the ratio of plant catch to reference catch. Time series separated by age groups were examined. Based on intervention analysis, no change in the abundance of fish populations could be attributed to plant operation. Additionally, a modification of the intervention analysis technique was applied to investigate trends in abundance at both the plant discharge and reference transects. Significant declines were detected for abundance of alewife adults at both of the transects. Results of the trend analysis support the contention that the alewives have undergone a lakewide decrease in abundance during the 1970s

  2. Environmental Impact Assessment for Olkiluoto 4 Nuclear Power Plant Unit in Finland

    International Nuclear Information System (INIS)

    Dersten, Riitta; Gahmberg, Sini; Takala, Jenni

    2008-01-01

    In order to improve its readiness for constructing additional production capacity, Teollisuuden Voima Oyj (TVO) initiated in spring 2007 the environmental impact assessment procedure (EIA procedure) concerning a new nuclear power plant unit that would possibly be located at Olkiluoto. When assessing the environmental impacts of the Olkiluoto nuclear power plant extension project, the present state of the environment was first examined, and after that, the changes caused by the projects as well as their significance were assessed, taking into account the combined impacts of the operations at Olkiluoto. The environmental impact assessment for the planned nuclear power plant unit covers the entire life cycle of the plant unit. (authors)

  3. Environmental Impact Assessment for Olkiluoto 4 Nuclear Power Plant Unit in Finland

    Energy Technology Data Exchange (ETDEWEB)

    Dersten, Riitta; Gahmberg, Sini; Takala, Jenni [Teollisuuden Voima Oyj, Olkiluoto, FI-27160 Eurajoki (Finland)

    2008-07-01

    In order to improve its readiness for constructing additional production capacity, Teollisuuden Voima Oyj (TVO) initiated in spring 2007 the environmental impact assessment procedure (EIA procedure) concerning a new nuclear power plant unit that would possibly be located at Olkiluoto. When assessing the environmental impacts of the Olkiluoto nuclear power plant extension project, the present state of the environment was first examined, and after that, the changes caused by the projects as well as their significance were assessed, taking into account the combined impacts of the operations at Olkiluoto. The environmental impact assessment for the planned nuclear power plant unit covers the entire life cycle of the plant unit. (authors)

  4. Maryland power plants and the environment: A review of the impacts of power plants and transmission lines on Maryland's natural resources. Biannually report

    International Nuclear Information System (INIS)

    1993-03-01

    The report, published biannually by Maryland's Power Plant Research Program, is a summary of current information related to environmental impacts associated with electric power generation in Maryland. Topics discussed in detail include: Power Supply and Demand; Air Quality; Surface and Groundwater Impacts; Terrestrial Impacts; Radiological Impacts; and Acid Deposition

  5. Impact of wind power plant reactive current injection during asymmetrical grid faults

    DEFF Research Database (Denmark)

    Göksu, Ömer; Teodorescu, Remus; Bak, Claus Leth

    2013-01-01

    As more renewable energy sources, especially more wind turbines (WTs) are installed in the power system; grid codes for wind power integration are being generated to sustain stable power system operation with non-synchronous generation. Common to most of the grid codes, wind power plants (WPPs...... faults, is investigated, which was not considered in the wind power impact studies before....

  6. Impact of external grid disturbances on nuclear power plants; Rueckwirkungen von Netzstoerungen auf Kernkraftwerke

    Energy Technology Data Exchange (ETDEWEB)

    Arains, Robert; Arnold, Simone; Brueck, Benjamin; Mueller, Christian; Quester, Claudia; Sommer, Dagmar

    2017-06-15

    The electrical design of nuclear power plants and the reliability of their electrical power supply including the offsite power supply are of high importance for the safe operation of the plants. The operating experience of recent years has shown that disturbances in the external grid can have impact on the electrical equipment of nuclear power plants. In the course of this project, possible causes and types of grid disturbances were identified. Based on these, scenarios of grid disturbances were developed. In order to investigate the impact of the developed scenarios of grid disturbances on the electrical equipment of nuclear power plants, the auxiliary power supply of a German pressurized water reactor of type Konvoi was simulated using the simulation tool NEPLAN. On the basis of the results of the analyses, it was identified whether there are possible measures to prevent the spread of grid disturbances in the plants which have not been implemented in the nuclear power plants today.

  7. Community leaders' perspectives on socio-economic impacts of power-plant development

    International Nuclear Information System (INIS)

    Hastings, M.; Cawley, M.E.

    1981-01-01

    The primary focus of this research effort was to identify and measure the socioeconomic impacts of power plant development on non-metropolitan host communities. A mail survey, distributed to community leaders in 100 power plant communities east of the Mississippi River, was utilized to gather information from 713 respondents. Community leaders were questioned as to the plant's impact on (a) community groups, (b) aspects of community life, (c) overall community acceptance and (d) attitudes toward power plant development. Overall, the trends and patterns of plant impact on the host communities were found to be largely positive. Specifically, local employment opportunities were generally enhanced with the advent of the power plant. Directly related to power plant development was the overall improvement of the local economic situation. Off-shoots from such in the economic area included related general improvements in the community quality of life. While the vast majority of community leaders responded with positive comments on power plant presence, adverse impacts were also mentioned. Negative comments focused on environmental problems, deterioration of roads and traffic conditions, and the possibility of nuclear accidents. Despite these negative impacts, almost two-thirds of the community leaders would definitely support the reconstruction of the same energy facility. Power plant development, therefore, is generally perceived as both a positive and beneficial asset for the host area. (author)

  8. Geothermal power plants principles, applications, case studies and environmental impact

    CERN Document Server

    DiPippo, Ronald

    2012-01-01

    Now in its 3e, this single resource covers all aspects of the utilization of geothermal energy for power generation using fundamental scientific and engineering principles. Its practical emphasis is enhanced by the use of case studies from real plants that increase the reader's understanding of geothermal energy conversion and provide a unique compilation of hard-to-obtain data and experience. Important new chapters cover Hot Dry Rock, Enhanced Geothermal Systems, and Deep Hydrothermal Systems. New, international case studies provide practical, hands-on knowledge.

  9. Socio-environmental impacts of Angra dos Reis nuclear power plant

    International Nuclear Information System (INIS)

    Rosa, L.P.; Hesles, J.B.S.

    1984-01-01

    Technological aspects and the social problematic inherent to implementation of nuclear power plants in Brazil are studied. it is showed the study in two levels: one of them, attacks aspects linked to nuclear energy and their risks in Brazil; the other one, treats of impacts of the Angra dos Reis nuclear power plants on the local comunity. (M.C.K.) [pt

  10. The subject deserving wide attention for nuclear power plant siting and environmental impact assessment

    International Nuclear Information System (INIS)

    Li Yong; Li Wenhui; Zhang Lingyan

    2009-01-01

    Based on siting work of nuclear power plant, the characteristics of nuclear power plant site selection and environmental impact assessment are analysed in accordance with laws and regulations of nuclear safety and environmental protection. Some subjects deserving attentions are put forward. (authors)

  11. Distributional effects of the fiscal impact of power plant siting

    International Nuclear Information System (INIS)

    Vogt, D.P.; Bjornstad, D.J.

    1976-01-01

    Classical economic base analysis is grounded in the concept that export activity drives the local economy and that economic impacts due to development can be traced to changes in the export base. Local government activities are frequently treated as a consequence of economic change, but no significant economic impact has been associated with imported tax dollars. In this paper the siting of a power reactor is examined, and it is concluded that the major economic impact related to the siting may result from increases in the tax base, which permit either increased public expenditure or increased disposable income through tax rate decreases. It is argued that as the fraction of the tax base that is owned nonlocally increases, the community perceives a price change, since smaller amounts of local income must be foregone to purchase a constant level of public services. This relationship is estimated using a sample of rural counties drawn from the State of Tennessee. The empirical results generally support the importance of the price variable in determining discretionary expenditures out of local disposable incomes. This finding conforms to other results obtained through an examination of actual reactor sitings, and points to the importance of understanding community responses to increased tax base for understanding local economic impacts from reactor siting

  12. Introduction of nuclear power plant for mitigating the impact of global warming

    International Nuclear Information System (INIS)

    Ida Nuryatin Finahari

    2008-01-01

    Energy utilization for power plants in Indonesia is still highly depending on the burning of fossil fuel like coal, oil, and gas. From the combustion of fossil fuel, greenhouse gases such as CO 2 and N 2 O are produced. An increase of CO 2 gas emission to the atmosphere can block the heat loss from the earth surface and will increase the greenhouse effect that results in the temperature increase of the earth surface (global warming). Global warming can cause a very extreme climate change on earth. One of the solutions to reduce CO 2 gas emission produced by fossil fuel power plants is to utilize the plants with flue gas treatment facility. At such facility, CO 2 gas is reacted with certain mineral based substances thus can be used as base material in food-, pharmaceutical-, construction-, and cosmetic industry. Another alternative to reduce CO 2 gas emission is by replacing fossil fuel power plants with nuclear power plants. Considering the environmental and economic aspects, the nuclear power plant does not emit CO 2 gas, so that the use of nuclear power plant can mitigate the impact of global warming. Based on the operational experience of nuclear power plants in advanced countries, the cost of generating electricity from nuclear power plants is more competitive than that of fossil fuel power plant. (author)

  13. Assessing the impact of power plant mortality on the compensatory reserve of fish populations

    International Nuclear Information System (INIS)

    Goodyear, C.P.

    1977-01-01

    A technique is presented to quantify the concepts of compensation and compensatory reserve in exploited fish populations. The technique was used to examine the impact of power plant mortality on a hypothetical striped bass population. Power plant mortality had a more severe impact on the compensation ratio and compensatory reserve for an exploited stock. The technique can be applied to determine a critical compensation ratio which could serve as a standard against which additional sources of mortality, such as those caused by power plants, could be measured

  14. Impact of power uprate on environmental qualification of equipment in nuclear power plants

    International Nuclear Information System (INIS)

    Raheja, R.D.; Mohiuddin, A.; Alsammarae, A.

    1996-01-01

    Many nuclear power facilities are finding it economically beneficial to increase reactor output, from operating plants, by resorting to power uprates. A power uprate implies that a utility can increase the reactor output, or the megawatts generated, by increasing steam pressure without adding or changing any plant systems. This is perhaps one of the least expensive options for increasing the generating capacity of a power plant. However, a nuclear plant requires a comprehensive review of the plant systems, structures and components to assure their capability to withstand the resulting increased normal and accident plant conditions. A power uprate will typically result in a plant operating at higher than the originally designed environmental conditions. Safety related equipment in nuclear plants is presently qualified to the UFSAR Chapter 15 accident events and the resulting temperatures, pressures, radiation levels etc. These values will increase when the reactor is producing a higher MWe output. Components that are sensitive to the environment must be re-evaluated and assessed to determine their acceptability and operability under the revised environmental conditions. Most safety-related mechanical and electrical equipment will require an assessment from an environmental qualification standpoint. Utilities must perform this task in a systematic, auditable and cost effective manner to optimize their resources and minimize plant costs associated with modifications, replacements or equipment testing. This paper discusses various approaches and provides recommendations to achieve equipment qualification while satisfying the plant's objective of a power uprate

  15. Ecological impacts and damage - comparison of selected components for nuclear and conventional power plants (example of Mochovce nuclear power plant)

    International Nuclear Information System (INIS)

    Bucek, M.

    1984-01-01

    A comparison is given of ecological damage for the nuclear power plant in Mochovce and a conventional power plant with the same power. Ecological effects and damage are divided into three groups: comparable damage, ecological damage caused only by conventional power plants and ecological damage caused only by nuclear power plants. In the first group the factors compared are land requisition, consumption of utility water and air consumption. In the second group are enumerated losses of crops (cereals, sugar beet, potatoes, oleaginous plants) and losses caused by increased disease rate owing to polluted environment by conventional power plants. In the third group health hazards are assessed linked with ionizing radiation. Also considered are vent stack escapes. (E.S.)

  16. State and local planning procedures dealing with social and economic impacts from nuclear power plants

    International Nuclear Information System (INIS)

    Curry, M.; Goodrieght, J.; Green, M.; Merwin, D.; Smith, R.

    1977-01-01

    The roles of state and local agencies in planning for and managing social and economic impacts of nuclear power plants are studied. In order to be effective in these roles state and local agencies must work with each other as well as the NRC. A comparative case study approach is used which analyzes six sites in three West Coast states. The case studies included plants in operation, plants under construction, and plants still in the planning stages. In contrast to some states, all three of these states have moderately centralized procedures for siting power plants, and all have strong environmental laws

  17. CO2 Price Impacts on Nuclear Power Plant Competitiveness in Croatia

    International Nuclear Information System (INIS)

    Tomsic, Z.; Pasicko, R.

    2010-01-01

    Long term power system planning faces growing number of concerns and uncertainties, which is especially true for nuclear power plants due to their high investment costs and financial risk. In order to analyze competitiveness of nuclear power plants and optimize energy mix, existing models are not sufficient anymore and planners need to think differently in order to face these challenges. Croatia will join EU ETS (European Emission Trading Scheme) with accession to EU (probably in 2012). Thus, for Croatian electrical system it is very important to analyze possible impacts of CO 2 emissions. Analysis presented in this paper is done by electricity market simulation model PLEXOS which was used for modelling Croatian electrical system during development of the Croatian Energy Strategy in 2008. Paper analyzes impacts of CO 2 price on competitiveness of nuclear power plant within Croatian power system between 2020 and 2025. Analyzes are focused on how nuclear power plant influences total emission from the power system regarding coal and gas prices, average electricity price regarding CO 2 , coal and gas prices price. Results of this paper are showing that with emissions from Energy strategy development scenario with two new coal power plants (600 MW each) and two new gas power plants (400 MW each) until 2020, Croatia does not meet Kyoto target due to this emissions from power system. On the other side, introduction of nuclear power plants presented in this paper (1000 MW instead of one coal and one gas power plant) means nearly 6.5 Mt CO 2 emissions less annually and gives possibility to achieve Kyoto target (as this reduced amount represents nearly 22 % of Croatian Kyoto target). Results are also showing how increase in CO 2 price is enhancing competitiveness of a nuclear power plant.(author).

  18. Evaluation of the impact on the environment of thermal power plant releases

    International Nuclear Information System (INIS)

    Roussel, C.; Bertrand, R.; Garnier, G.; Berard, P.; Archimbaud, M.

    1983-01-01

    The aim of this study is to compare the impact on the environment of oil and coal fired power plants, and of nuclear plants. The impact is evaluated by the level of the air pollution around the plant. But the selected pollutants (Sulfur oxides, Nitrogen oxides, Trace elements, organic compounds) are not specific of the pollution produced by the power plant. Therefore, we measured the specific emission of the plant by a continuous sampling in the stack gases. To evaluate the contribution of the plant to the global pollution, a series of diffusion tests was run to measure the atmospheric transfer between the stack and the monitoring system. Sulfur hexafluoride (SF6) was added to the stack plume and its concentration was measured in the environment continuously at the monitoring stations, and by a mobile network for tracing the movement of the plume due to a shift in wind direction. Thereby the impact of other sources could be estimated [fr

  19. Study on the radiological Impact of Coal Fired Power Plants

    International Nuclear Information System (INIS)

    Cancio, D.; Robles, B.; Mora, J. C.; Baeza, A.; Corbacho, J. A.; Vasco, J.; Guillen, J.

    2008-01-01

    The study is part of the goal set forth in Title VII of the European Basic Safety Standards and the Spanish regulations on radiation protection related to work activities that may involve a significant increase in exposure of workers and the public to natural radiation. Coal contains small quantities of radionuclides in the series of uranium, thorium and potassium which in the industrial process can lead to radiological exposure. This work presents the measurements and evaluations conducted in one of the power plants object of study: The Unidad Termica de Produccion de Litoral in the Almeria Province. The maximum dose assessed for workers are in the order of 0.14 mSv per year and in the order of 0.05 mSv per year for the public in the realistic scenarios considered. These values are well below the 1mSv per year reference levels, recommended in Europe to have some interest from the radiation protection point of view. (Author) 52 refs

  20. Socioeconomic impacts of nuclear power plant siting: a case study of two New England communities

    International Nuclear Information System (INIS)

    Purdy, B.J.

    1976-01-01

    An examination is presented of the social, economic and political/institutional impacts of two operating nuclear power complexes on two New England communities. The work is one of a series planned to broaden knowledge of the effects of large energy-generating facilities upon the social structure of local communities. Its primary objectives are to investigate and assess social and economic impacts resulting from construction and operation of nuclear power plants and to generate hypotheses about such impacts for future testing

  1. Decision support systems for power plants impact on the living standard

    International Nuclear Information System (INIS)

    Chatzimouratidis, Athanasios I.; Pilavachi, Petros A.

    2012-01-01

    Highlights: ► Ten major types of power plant are evaluated as to their impact on living standard. ► Uncertainty in both criteria performance and criteria weighting is considered. ► PROMETHEE II method, 12 criteria and 13 scenarios are used. ► Results are presented per scenario and per type of power plant. ► Optimal solution depends on scenario assumptions of the decision maker. - Abstract: In developed countries, the quality of life is of first priority and an overall assessment of power plant impact on the living standard requires a multicriteria analysis of both positive and negative factors incorporating uncertainty in criteria performance and probability assessment of weighting factors. This study incorporates PROMETHEE II to assess 10 major types of power plant under 12 criteria, 13 fixed and infinite customized probability assessed weight set scenarios. The power plants considered are coal/lignite, oil, natural gas turbine, natural gas combined cycle, nuclear, hydro, wind, photovoltaic, biomass and geothermal. Geothermal, wind and photovoltaic power plants are excellent choices in most of the cases and biomass and hydro should also be preferred to nuclear and fossil fuel. Among nuclear and fossil fuel the choice is based on the specific parameters of each case examined while natural gas technologies have specific advantages. The motivation of this study was to provide a tool for the decision-maker to evaluate all major types of power plant incorporating multicriteria and customized probability assessment of weighting factors.

  2. Preparation of environmental reports and impact statements for nuclear power plants

    International Nuclear Information System (INIS)

    Tsai, Y.H.

    1986-01-01

    Considerable first-hand experience has accumulated during the past decade in the United States regarding the preparation of environmental reports (ER) and environmental impact statements (EIS) for nuclear power plants. The US Nuclear Regulatory Commission (USNRC), which is responsible for regulating the construction and operation of nuclear power plants, is required under the National Environmental Policy Act to prepare an EIS for each plant. To obtain information essential to the EIS, the USNRC requires that each power company submit an ER. This paper focuses on the interrelationships of the two environmental documents and discusses the environmental review process and the environmental laws and regulations related to the licensing of nuclear power plants. It also describes the format and content, environmental issues, data requirements, and impact assessment methodologies for preparation of the ER and EIS. Problems associated with preparing the EIS are presented, with particular emphasis on the problems and methodologies associated with evaluating environmental costs and benefits

  3. Impact of major design parameters on the economics of Tokamak power plants

    International Nuclear Information System (INIS)

    Abdou, M.A.; Ehst, D.; Maroni, V.; Stacey, W.M. Jr.

    1977-11-01

    A parametric systems studies program is now in an active stage at Argonne National Laboratory. This paper presents a summary of results from this systems analysis effort. The impact of major design parameters on the economics of tokamak power plants is examined. The major parameters considered are: (1) the plant power rating; (2) toroidal-field strength; (3) plasma β/sub t/; (4) aspect ratio; (5) plasma elongation; (6) inner blanket/shield thickness; and (7) neutron wall load. The performance characteristics and economics of tokamak power plants are also compared for two structural materials

  4. Radiological impact from airborne routine discharges of Coal-Fired power plant

    International Nuclear Information System (INIS)

    Norasalwa Zakaria; Rohyiza Baan; Kathiravale, Sivapalan

    2010-01-01

    Radioactivity exists everywhere in nature. We are exposed to intense and continuous natural radiation coming from the sun, cosmic radiation, telluric radiation and even to the internal radiation of our own body. The fly ash emitted from burning coal for electricity by a power plant carries into the surrounding environment 100 times more radiation than a nuclear power plant producing the same amount of energy. This paper presents the information of studies on the radiological impact from airborne routine discharge of coal-fired power plants. (author)

  5. Socioeconomic impacts of nuclear power plants: a paired comparison of operating facilities

    International Nuclear Information System (INIS)

    Shields, M.A.; Cowan, J.T.; Bjornstad, D.J.

    1979-07-01

    This study compares the social, economic, and political effects of constructing and operating two nuclear power plants in the rural Southeast: Brunswick 1 and 2 in Brunswick County, North Carolina, and Hatch 1 and 2 in Appling County, Georgia. It is a comparative, post-licensing case study designed to analyze variations in the range and magnitude of impacts experienced by the areas in which the plants were constructed. The study is intended to assist the Nuclear Regulatory Commission in the preparation of socioeconomic impact sections of environmental impact statements for proposed nuclear power stations

  6. Exergy and Environmental Impact Assessment between Solar Powered Gas Turbine and Conventional Gas Turbine Power Plant

    Directory of Open Access Journals (Sweden)

    Ali Rajaei

    2016-01-01

    Full Text Available Recuperator is a heat exchanger that is used in gas turbine power plants to recover energy from outlet hot gases to heat up the air entering the combustion chamber. Similarly, the combustion chamber inlet air can be heated up to temperatures up to 1000 (°C by solar power tower (SPT as a renewable and environmentally benign energy source. In this study, comprehensive comparison between these two systems in terms of energy, exergy, and environmental impacts is carried out. Thermodynamic simulation of both cycles is conducted using a developed program in MATLAB environment. Exergetic performances of both cycles and their emissions are compared and parametric study is carried out. A new parameter (renewable factor is proposed to evaluate resources quality and measure how green an exergy loss or destruction or a system as a whole is. Nonrenewable exergy destruction and loss are reduced compared to GT with recuperator cycle by 34.89% and 47.41%, respectively. Reductions in CO2, NOx, and CO compared to GT with recuperator cycle by 49.92%, 66.14%, and 39.77%, respectively, are in line with renewable factor value of around 55.7 which proves the ability of the proposed green measure to evaluate and compare the cycles performances.

  7. Assessing aesthetic impacts in siting a nuclear power plant: the case of Greene County, New York

    International Nuclear Information System (INIS)

    Petrich, C.H.

    1982-01-01

    In the aesthetic impact analysis of the Greene County Nuclear Power Plant, vivid symbols of modern technology - a domed reactor containment structure and a monolithic natural-draft cooling tower - played the dominant roles in the conflict with a remnant landscape of America's romantic past. The analysis revealed, and the NRC affirmed, that the proposed plant would entail an unacceptable aesthetic impact, beyond mitigation, on certain important local, regional, and national historic, scenic, and cultural resources

  8. Impact of Wind Power Plants on Voltage Control of Power System

    DEFF Research Database (Denmark)

    Sarkar, Moumita; Altin, Müfit; Hansen, Anca Daniela

    High penetration of renewable energy sources poses numerous challenges on stability and security of power systems. Wind power plants (WPPs) of considerable size when connected to a weak grid by long transmission line results in low short circuit ratio at the point of connection. This may result...... control, during transient voltage dips. Steady-state analysis is performed for stressed system conditions. Results are validated through simulation in a detailed power system model....

  9. Aesthetic impact assessment of solar power plants. An objective and a subjective approach

    Energy Technology Data Exchange (ETDEWEB)

    Torres-Sibille, Ana del Carmen; Cloquell-Ballester, Vicente-Agustin; Cloquell-Ballester, Victor-Andres; Artacho Ramirez, Miguel Angel [Dpto. Proyectos de Ingenieria, Valencia University of Technology, Camino de Vera s/n, 46022 Valencia (Spain)

    2009-06-15

    Solar energy for the production of electric energy is one source of renewable energy which is experiencing most development in recent years. In countries with high solar radiation indices, as is the case of Spain, expectations of installation of large solar power plants are increasing. Most solar power plants are located in rural environments, where the landscape has remained practically unaltered ever since extensive agriculture was introduced. Because of this, one of the most significant environmental impacts of this type of installation is the visual impact derived from the alteration of the landscape. In this work, an indicator is proposed for the quantification of the objective aesthetic impact, based on four criteria: visibility, colour, fractality and concurrence between fixed and mobile panels. The relative importance of each variable and the corresponding value functions are calculated using expert contribution. A study of the subjective aesthetic impact is then carried out using the semantic differential method, to obtain the perception of a sample of individuals of the initial landscapes and of the landscapes altered through the installation of a solar power plant. The indicator and the study of public perception are applied to five real solar power plants, to test their reliability. Subsequently, a different group of individuals is used to determine preferences between the five solar power plants. The study proves that the combined use of objective indicator and subjective study, faithfully explains user preferences corresponding to the combined comparisons of the five cases. It is concluded that the tools proposed for the evaluation of the aesthetic impact of solar power plants are useful for the selection of optimal plant location and most adequate use of panel technology, to minimise aesthetic impact. (author)

  10. Study of the Radiological Impact of the Coal Fired Power Plants on the Environment. The As Pontes coal-fired Power Plant

    International Nuclear Information System (INIS)

    Cancio, D.; Robles, B.; Mora, J. C.

    2009-01-01

    As part of the Study carried out to determine the radiological impact of the four main Spanish coal-fired power plants, the Study on the As Pontes Coal-Fired Coal Power Plant was finalized. In the Report containing the study are included every measurement performed, as well as the modelling and evaluations carried out in order to assess the radiological impact. The general conclusion obtained is that under a radiological point of view, the impact of this installation on the public and the environment is very small. Also the radiological impact on the workers of the installation was assessed, obtaining too very small increases over the natural background. (Author) 61 refs.

  11. Potential impact of thermal effluents from Chongqing Fuling nuclear power plant to the Three Gorges Reservoir

    International Nuclear Information System (INIS)

    Han Baohua; Li Jianguo; Ma Binghui; Zhang Yue; Sun Qunli; Hu Yuping

    2012-01-01

    This study is based on the hydrological data near Chongqing Fuling Nuclear Power Plant along the Yangtze River, the present situation of the ecological environment of the Three Gorges Reservoir and the predicted results of thermal effluents from Chongqing Fuling Nuclear Power Plant. The standards of cooling water and the thermal tolerances indexes of aquatic organisms were investigated. The effects of thermal effluents on aquatic organisms were analyzed. The potential impact of Chongqing Fuling nuclear power plant to the Three Gorges Reservoir was explained. The results show that in the most adverse working conditions, the surface temperature near the outfall area is not more than 1℃, the temperature of thermal effluents do not exceed the suitable thermal range of fish breeding, growth and other thermal tolerances indexes. Thermal effluents from nuclear power plant have no influence about fish, plankton and benthic organisms in the Three Gorges Reservoir. (authors)

  12. Innovative approach to ash radioactivitiy and health impacts of lignite power plants

    Energy Technology Data Exchange (ETDEWEB)

    Bosevski, T.; Pop-Jordanova, N. [Macedonian Academy of Sciences and Arts, Skopje (Macedonia)

    1998-12-31

    In Macedonia nearly 90% of the present electricity production utilizes domestic low-calorie lignite, and this is likely to continue for the next few decades. Local and global environmental impacts of fossil fuel utilization are considered. Some innovative extensions to standard methodologies of environmental risk assessment and management are considered. They involve ash radioactivity and psychosomatic health impacts from lignite power plants. Two extensions are proposed: one comprising complete radioactive chains when determining committed effective dose from lignite ash; the other by including the psychosomatic diseases, such as peptic ulcer and arterial hypertension, due to chronic stress induced by power plants during normal operation. 7 refs., 2 figs., 3 tabs.

  13. Preliminary Study on Impact Resistances of Fiber Reinforced Concrete Applied Nuclear Power Plants

    International Nuclear Information System (INIS)

    Jin, Byeong Moo; Kim, Young Jin; Jeon, Se Jin

    2013-01-01

    Studies to improve the impact resistance depending upon design parameters for fiber reinforced concrete, such as type of fibers and application ratio, are in progress. Authors assessed first the impact resistance of concrete walls depending upon fiber types and missile impact velocities. The safety assessment of nuclear power plants against large civil aircraft crashes have been accomplished for normal concrete and fiber reinforced concretes in this study. Studies on the safety assessments on the nuclear power plants against large civil aircraft crashes are ongoing actively. As a step of evaluating the applicability of fiber reinforced concrete in means of ensuring more structural safety of the nuclear power plants against impact, the impact resistance for the 1% steel and 2% polyamide fiber reinforced concretes have been evaluated. For reactor containment building structures, it seem there is no impact resistance enhancement of fiber reinforced concrete applied to reactor containment building in the cases of impact velocity 150 m/sec considered in this study. However this results from the pre-stressing forces which introduce compressive stresses in concrete wall and dome section of reactor containment building. Nonetheless there may be benefits to apply fiber reinforced concrete to nuclear power plants. For double containment type reactor containment building, the outer structure is a reinforced concrete structure. The impact resistances for non pre-stressed cylindrical reactor containment buildings are enhanced by 23 to 47 % for 2 % polyamide fiber reinforced concretes and 1 % steel fiber reinforced concretes respectively. For other buildings such as auxiliary building, compound building and fuel storage building surrounding the reactor containment building, there are so many reinforced concrete walls which are anticipated some enhancements of impact resistance by using fiber reinforced concretes. And heavier or faster large civil aircraft impacts produce higher

  14. Preliminary Study on Impact Resistances of Fiber Reinforced Concrete Applied Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Byeong Moo; Kim, Young Jin; Jeon, Se Jin [Daewoo E and C Co. Ltd., Suwon (Korea, Republic of)

    2013-10-15

    Studies to improve the impact resistance depending upon design parameters for fiber reinforced concrete, such as type of fibers and application ratio, are in progress. Authors assessed first the impact resistance of concrete walls depending upon fiber types and missile impact velocities. The safety assessment of nuclear power plants against large civil aircraft crashes have been accomplished for normal concrete and fiber reinforced concretes in this study. Studies on the safety assessments on the nuclear power plants against large civil aircraft crashes are ongoing actively. As a step of evaluating the applicability of fiber reinforced concrete in means of ensuring more structural safety of the nuclear power plants against impact, the impact resistance for the 1% steel and 2% polyamide fiber reinforced concretes have been evaluated. For reactor containment building structures, it seem there is no impact resistance enhancement of fiber reinforced concrete applied to reactor containment building in the cases of impact velocity 150 m/sec considered in this study. However this results from the pre-stressing forces which introduce compressive stresses in concrete wall and dome section of reactor containment building. Nonetheless there may be benefits to apply fiber reinforced concrete to nuclear power plants. For double containment type reactor containment building, the outer structure is a reinforced concrete structure. The impact resistances for non pre-stressed cylindrical reactor containment buildings are enhanced by 23 to 47 % for 2 % polyamide fiber reinforced concretes and 1 % steel fiber reinforced concretes respectively. For other buildings such as auxiliary building, compound building and fuel storage building surrounding the reactor containment building, there are so many reinforced concrete walls which are anticipated some enhancements of impact resistance by using fiber reinforced concretes. And heavier or faster large civil aircraft impacts produce higher

  15. Impact of Wind Power Plants with Full Converter Wind Turbines on Power System Small-Signal Stability

    DEFF Research Database (Denmark)

    Knüppel, Thyge; Nygaard Nielsen, Jørgen; Dixon, Andrew

    Wind power is being developed in power systems all around the world, and already today wind power covers more than 20 % of the electricity consumption in some countries. As the size of each wind power plant (WPP) increases and as the levels of penetration reaches certain magnitudes, the inclusion...... of the dynamic properties of the WPPs in the power system stability studies become important. The work presented in this report deal with the impact of WPPs based on full converter wind turbines (WTs) on the power system small-signal rotor angle stability. During small disturbances in the power system, the rotor...... speed of the synchronous machines will eventually return to its steady state if the power system is small-signal stable. The dynamic properties of a WPP are fundamentally dierent from those of a synchronous machine, and the interaction of WPPs with the synchronous machines in power system oscillations...

  16. Multicriteria evaluation of power plants impact on the living standard using the analytic hierarchy process

    International Nuclear Information System (INIS)

    Chatzimouratidis, Athanasios I.; Pilavachi, Petros A.

    2008-01-01

    The purpose of this study is to evaluate 10 types of power plants available at present including fossil fuel, nuclear as well as renewable-energy-based power plants, with regard to their overall impact on the living standard of local communities. Both positive and negative impacts of power plant operation are considered using the analytic hierarchy process (AHP). The current study covers the set of criteria weights considered typical for many local communities in many developed countries. The results presented here are illustrative only and user-defined weighting is required to make this study valuable for a specific group of users. A sensitivity analysis examines the most important weight variations, thus giving an overall view of the problem evaluation to every decision maker. Regardless of criteria weight variations, the five types of renewable energy power plant rank in the first five positions. Nuclear plants are in the sixth position when priority is given to quality of life and last when socioeconomic aspects are valued more important. Natural gas, oil and coal/lignite power plants rank between sixth and tenth position having slightly better ranking under priority to socioeconomic aspects

  17. Problems of economic assessment of social impacts of construction anO operation of nuctear power plant in the area

    International Nuclear Information System (INIS)

    Koudelka, F.

    1984-01-01

    The impacts of nuclear power plant construction and operation are divided into economic, demographic, on town planning, historic, etc. Further subdivision is performed according to the intensity of construction impacts, to the sequence and quality of impact and to the effects in space and time. The area of environmental impacts is classified into the protective area and the areas of immediate, limited and broad impact. The methods of the evaluation of nuclear power plant construction and operation impacts are discussed. (E.S.)

  18. Environmental Impacts From the Installation and Operation of Large-scale Solar Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Fthenakis, V.; Turney, Damon

    2011-04-23

    Large-scale solar power plants are being developed at a rapid rate, and are setting up to use thousands or millions of acres of land globally. The environmental issues related to the installation and operation phases of such facilities have not, so far, been addressed comprehensively in the literature. Here we identify and appraise 32 impacts from these phases, under the themes of land use intensity, human health and well-being, plant and animal life, geohydrological resources, and climate change. Our appraisals assume that electricity generated by new solar power facilities will displace electricity from traditional U.S. generation technologies. Altogether we find 22 of the considered 32 impacts to be beneficial. Of the remaining 10 impacts, 4 are neutral, and 6 require further research before they can be appraised. None of the impacts are negative relative to traditional power generation. We rank the impacts in terms of priority, and find all the high-priority impacts to be beneficial. In quantitative terms, large-scale solar power plants occupy the same or less land per kW h than coal power plant life cycles. Removal of forests to make space for solar power causes CO{sub 2} emissions as high as 36 g CO{sub 2} kW h{sup -1}, which is a significant contribution to the life cycle CO{sub 2} emissions of solar power, but is still low compared to CO{sub 2} emissions from coal-based electricity that are about 1100 g CO{sub 2} kW h{sup -1}.

  19. Geographical evaluation of the impact of nuclear power plants on settlement structures

    International Nuclear Information System (INIS)

    Divinsky, B.

    1992-01-01

    The effects of nuclear power plants are classed with respect to their character (one-sided or many-sided), order (primary or secondary), quality (positive or adverse), duration (temporary or permanent), and space (microregional or macroregional). The following topics must be included in the methodology of evaluation of the impacts of a nuclear power plant on the region: characteristics of the present settlement network, relationships within the settlement system, spatial transformation of settlements, development of urbanization, population density, town and village sizes, functional types of settlements, migration, age and social structure of the population, economic activity, town and village facilities, technical infrastructure, transport and traffic, psycho-social impacts of the occurrence of the nuclear power plant, microecology (microenvironment). (M.D.). 5 refs

  20. Maryland power plants and the environment. A review of the impacts of power plants and transmission lines on Maryland's natural resources

    International Nuclear Information System (INIS)

    1999-01-01

    The Maryland Department of Natural Resources (DNR) Power Plant Research Program (PPRP) is required by Maryland law to review and evaluate the potential impacts to Maryland's environment from the construction and operation of electric power generating and transmission systems. PPRP summarizes these evaluations every other year in a document known as the Cumulative Environmental Impact Report (CEIR). This volume represents the tenth edition (CEIR-10), and it summarizes the current state of knowledge which PPRP has gained from more than 25 years of continuous monitoring of power plant impacts in Maryland. PPRP conducts a range of research and monitoring projects on the topics addressed in this CEIR and many other issues as well. In fact, PPRP publishes a Bibliography every year that lists the general and site-specific power plant related reports that PPRP has produced since the early 1970s

  1. Estimation of the economic impacts of Three Mile Island nuclear power plant accident

    International Nuclear Information System (INIS)

    Sagara, Aya; Fujimoto, Noboru; Fukuda, Kenji

    1998-01-01

    The Three Mile Island nuclear power plant accident had an immediate negative impact on the economy of the seven-country area which surrounds the plant site. In order to estimate the social effect of the nuclear power plant accident economically, immediate and short term economical impacts on some industrial classification have been evaluated. The economical effect to Metropolitan Edison Co., the circumstantial payment of the insurance and the lawsuit for the compensation for damages, etc. have been estimated at dollar 90 million for the manufacturing and nonmanufacturing industry, dollar 5 million for the tourist industry and dollar 50,000 for agriculture. The total loss for the state and country governments is about dollar 90,000. Metropolitan Edison Co. expended also dollar 111 million for the substitute energy and dollar 760 million for the decontamination cost. Since the lawsuit for the compensation for damages is still continuing, the total impacts cost is calculated more than a billion dollar. (author)

  2. Impacts of carbon capture on power plant emissions

    Energy Technology Data Exchange (ETDEWEB)

    Narula, R.; Wen, H. [Bechtel Power, San Francisco, CA (United States)

    2009-07-01

    Post-combustion carbon dioxide capture processes currently include amine-based solvent scrubbing and ammonia solution scrubbing technologies. Both result in high emissions of volatile organic compounds (VOC) and ammonia, as well as liquid discharge that contain chemical solvent. Additional solid wastes include sludge and spent solvent filtration medias. Process simulation software can be used to predict the amount of solvent vapor in the stack gas for both amine and ammonia solvent based capture processes. However, amine could decompose in most amine-based processes and release ammonia gas due to degradation by exposure to oxygen, sulfur impurities, and thermal conditions. As a regulated pollutant for emission control for some plants, ammonia emissions are a major concern for ammonia scrubbing processes. The energy requirement for carbon capture can be reduced by cooling the flue gas before entering the carbon dioxide absorber column. The resulting low flue gas temperature could create difficulties in dispersing the flue gas plume in the atmosphere. This paper presented a computer simulation of stack emission reduction.

  3. Potential impacts of nuclear power plant operation on the public

    International Nuclear Information System (INIS)

    Kotulan, J.

    1999-01-01

    Findings from the examination of the health status of population living in the vicinity of nuclear facilities abroad (England, France, Germany ...) are summarized. Where a significant increase in the incidence of leukemia in children and non-Hodgkin's lymphomas were observed, these are not attributed to radioactivity; rather, the virus theory seems to account best for this phenomenon. Author's findings in the area of the Dukovany NPP in the Czech Republic (which have been published) are summarized as follows: (i) Total mortality 1986-1994 in the vicinity of the plant is the same as or lower than in reference regions; (ii) This also applies to premature deaths and to the 'lost years' indicator; (iii) Death rate due to tumors is significantly lower than in reference regions; (iv) This also applies to the majority of the individual types of tumors; (v) Leukemia seems to be an exception, its incidence being higher than in reference regions. The absolute figures, however, are low (11 + 17 in the exposed region) and the differences are not statistically significant. This also applies to lymphatic tissue tumors. (7) Mental well-being was no different from the reference region; in some respects, surprisingly enough, it even appeared to be more favourable. (P.A.)

  4. Changing information needs of social impact of nuclear power plant siting. Through a comparison before and after the Fukushima Daiichi nuclear power plant accident

    International Nuclear Information System (INIS)

    Kashiwa, Takako; Kawamoto, Yoshimi

    2013-01-01

    In the light of the Fukushima Daiichi nuclear power plant accident, we need to consider a symbiosis method based on the diminution of the nuclear power industry. To find a region that does not excessively depend on the nuclear power industry, it is necessary to examine and discuss the social impact of nuclear-related industries. In this study, we compared people's changing information needs of social impact before and after the Fukushima Daiichi nuclear power plant accident. It was found that the need for information increased after the accident. In particular, there were three research areas where the need for information increased: the consideration of building nuclear power plants, the influence of harmful rumors on the region, and influence on the nuclear power industry. Next, attempts were made to understand whether there is a difference between information needs of social impact by attributes, such as age, sex and knowledge of nuclear power. The information needs of the following categories of people increased after the accident: people aged between 10 and 50 years, women, people who do not have a clear opinion about the use of a nuclear power plant, and people who do not have any knowledge of nuclear power. (author)

  5. The potential environmental impacts and the siting of proposed nuclear power plants in China

    International Nuclear Information System (INIS)

    Shi Zhongqi

    1986-01-01

    This paper reviews briefly the methodology of assessing environmental impacts from the nuclear power plants and analyses the potential radiological impacts on the environment from proposed nuclear power plants in China. Preliminary studies show that the environmental impacts of the effluents of routine release from PWRs to the proposed sites are extremely small, even if nuclear power plants are constructed either on the Bohai Sea shore with a narrow mouth or in the densely populated regions of Sunan. Thus, the suitability of sites depends mainly on the acceptability of possible exposure to the residents following postulated accidental release of radioactive materials. The paper also discusses relations between the nuclear plant siting and population distribution around the site and compares the distribution of the proposed sites in China with that of other countries sites in according to China actual situation, it is reasonable to adopt a prudent policy that the first series of nuclear power plants in China should be built in relatively low population areas

  6. Ecological impact from large constructions of hydroelectric power plants in Parana River, Brazil

    International Nuclear Information System (INIS)

    Bonetto, Argentino A.

    1992-01-01

    An analysis over environmental impacts on Parana River as a result of the hydroelectric power plants construction is presented. Hydroelectric dams, also including the planned ones, are showing during the explanation, and biologic aspects are discussed. 30 refs., 4 figs., 2 tabs

  7. Study on the distribution coefficient during environmental impact evaluation in Chinese inland nuclear power plants

    International Nuclear Information System (INIS)

    Xu Haifeng; Shang Zhaorong; Chen Fangqiang

    2012-01-01

    Description the radionuclide distribution coefficient of the important factors in the river sediment systems, at home and abroad the main method of measuring the K d value and progress in China's inland nuclear power plant environmental impact assessment of workers to carry out the distribution coefficient K d value measurement ideas put forward recommendations. (authors)

  8. Environmental impact of natural radionuclides from the fossil fuel power plants

    International Nuclear Information System (INIS)

    Antic, D.

    1989-01-01

    A set of experimental data for selected coals in Yugoslavia is used for this study. The impact of natural radionuclides emitted from the coal fired power plants with these coals is analysed. Simple models are used to asses annual doses at the maximum concentration points. The calculated values are compared with the values from the literature for similar calculations (author)

  9. Discussion on the impact of large commercial airplane to nuclear power plant

    International Nuclear Information System (INIS)

    Tang Bo

    2010-01-01

    Briefly introducing the 10CFR50.150, draft guide and technical document of United States which is issued recently by NRC and NEI on impact of large commercial airplane to nuclear power plant, introducing comments from society and public and responses from NRC, and briefly discussing relevant issues. (author)

  10. Assessing power plant impacts on fish populations at Northeast Utilities sites: winter flounder studies at Millstone Nuclear Power Station

    International Nuclear Information System (INIS)

    Lorda, E.; Danila, D.J.; Miller, J.D.; Bireley, L.E.; Jacobsen, P.M.

    1987-01-01

    An historical view is presented of the various impact assessment approaches used to study the winter flounder, including efforts to identify and quantify compensation and to model its population dynamics. This review illustrates the need for unbiased estimates of basic life history parameters and power plant related mortalities if compensatory mechanisms are to be understood and if impact assessments are to be meaningful. 67 references, 19 figures, 10 tables

  11. The Kuroshio power plant

    CERN Document Server

    Chen, Falin

    2013-01-01

    By outlining a new design or the Kuroshio power plant, new approaches to turbine design, anchorage system planning, deep sea marine engineering and power plant operations and maintenance are explored and suggested. The impact on the local environment, particularly in the face of natural disasters, is also considered to provide a well rounded introduction to plan and build a 30MW pilot power plant. Following a literature review, the six chapters of this book propose a conceptual design by focusing on the plant's core technologies and establish the separate analysis logics for turbine design and

  12. Occidental Geothermal, Inc. , Oxy Geothermal Power Plant No. 1: draft environmental impact report

    Energy Technology Data Exchange (ETDEWEB)

    1981-08-01

    The following aspects of the proposed geothermal power plant are discussed: the project description; the environment in the vicinity of project as it exists before the project begins, from both a local and regional perspective; the adverse consequences of the project, any significant environmental effects which cannot be avoided, and any mitigation measures to minimize significant effects; the potential feasible alternatives to the proposed project; the significant unavoidable, irreversible, and long-term environmental impacts; and the growth inducing impacts. (MHR)

  13. Have U.S. power plants become less technically efficient? The impact of carbon emission regulation

    International Nuclear Information System (INIS)

    Zhou, Yishu; Huang, Ling

    2016-01-01

    We estimate directional distance functions to measure the impact of carbon emission regulation, the Regional Greenhouse Gas Initiative (RGGI) in particular, on U.S. power plants' technical efficiency. The model shows that the average technical efficiency scores for coal and natural gas plants are 88.70% and 83.14% respectively, indicating a very technically efficient industry. We find no evidence of technical efficiency changes due to the RGGI regime in the RGGI area. In the same area, relatively less efficient coal plants exited the market and slightly more efficient natural gas plants entered, compared to the incumbent plants. In addition, some evidence of a spillover effect is found. Using a counterfactual analysis, the RGGI regulation leads to a 1.48% decline in the average technical efficiency for coal plants within neighboring states of RGGI during 2009–2013. - Highlights: • RGGI does not lead to a change in the technical efficiency of RGGI power plants. • Less efficient coal plants exit. • Entering natural gas plants are more efficient. • RGGI has a spillover effect on neighboring coal plants.

  14. Legal advocacy and nuclear power: the impact of litigation on the Midland nuclear plant

    International Nuclear Information System (INIS)

    Cook, C.E.

    1979-01-01

    The use of litigation as an interest-group strategy is analyzed in relation to the controversy over the development of nuclear power. An assessment is made of the impact of the judicial process, with the litigation involving the Midland, Michigan, nuclear plant serving as a representative case study. In the construction permit hearings for the Midland nuclear plant, which began in 1970, the interest groups were Consumers Power Company, a Michigan utility, and the Saginaw and Mapleton Intervernors, environmentalists dwelling near the proposed plant site. The Nuclear Regulatory Commission issued a construction permit for the plant after a two-year licensing process, but the environmental groups appealed the permit to the United States Court of Appeals for the District of Columbia Circuit. In 1976, the permit was remanded by the court to the Commission for reconsideration, and Consumers Power Company appealed that decision. In 1978, the Supreme Court handed down a unanimous and definitive opinion, Consumers Power Company vs Aeschliman, that upheld the Commission's original issuance of the construction plant. The Midland case well illustrates the detrimental impact that legal advocacy has had on atomic energy by prolonging the regulatory process. The positive consequences of the Court ruling favoring the utility's position were outweighed by the expense involved in the initial ten years of thelicensing and subsequent lawsuits concerning the Midland plant. Consequently, Consumers Power Company is representative of most other American electric companies in its determination that it cannot build additional nuclear plants without mitigation of the uncertainty and duration of the regulatory process. Thus, it may be concluded that the environmental groups' use of legal advocacy at Midland and elsewhere has proven to be an effective strategy for undermining the nuclear industry and for deterring the future development of nuclear power

  15. Technology overview: assessment of social values in thermal power plant siting, social impact methodology evaluation

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    A methodology was developed to facilitate the selection of favorable thermal power plant site and design alternatives from the community perspective. A two-stage, multicriteria decision technique was employed to combine technical assessments of effects of the proposed site/design alternatives with corresponding community values. In the first stage, submodels are used to develop indices of plant impact on each of ten decision criteria. These criteria include effects on aesthetics, water quality, cost of power, air quality, ecology, social quality, local economy, recreational opportunities, cultural resources, and human health and safety. In the second stage, each of the impact indices is weighted by corresponding community values and then summed to provide an overall index of plant acceptability

  16. Development of the simulation system IMPACT for analysis of nuclear power plant severe accidents

    International Nuclear Information System (INIS)

    Naitoh, Masanori; Ujita, Hiroshi; Nagumo, Hiroichi

    1997-01-01

    The Nuclear Power Engineering Corporation (NUPEC) has initiated a long-term program to develop the simulation system IMPACT for analysis of hypothetical severe accidents in nuclear power plants. IMPACT employs advanced methods of physical modeling and numerical computation, and can simulate a wide spectrum of senarios ranging from normal operation to hypothetical, beyond-design-basis-accident events. Designed as a large-scale system of interconnected, hierarchical modules, IMPACT's distinguishing features include mechanistic models based on first principles and high speed simulation on parallel processing computers. The present plan is a ten-year program starting from 1993, consisting of the initial one-year of preparatory work followed by three technical phases: Phase-1 for development of a prototype system; Phase-2 for completion of the simulation system, incorporating new achievements from basic studies; and Phase-3 for refinement through extensive verification and validation against test results and available real plant data

  17. Evaluation of Haddam Neck (Connecticut Yankee) Nuclear Power Plant, environmental impact prediction, based on monitoring programs

    International Nuclear Information System (INIS)

    Gore, K.L.; Thomas, J.M.; Kannberg, L.D.; Mahaffey, J.A.; Waton, D.G.

    1976-12-01

    A study was undertaken by the U.S. Nuclear Regulatory Commission (NRC) to evaluate the nonradiological environmental data obtained from three nuclear power plants operating for a period of one year or longer. The document presented reports the second of three nuclear power plants to be evaluated in detail by Battelle, Pacific Northwest Laboratories. Haddam Neck (Connecticut Yankee) Nuclear Power Plant nonradiological monitoring data were assessed to determine their effectiveness in the measurement of environmental impacts. Efforts were made to determine if: (1) monitoring programs, as designed, can detect environmental impacts, (2) appropriate statistical analyses were performed and if they were sensitive enough to detect impacts, (3) predicted impacts could be verified by monitoring programs, and (4) monitoring programs satisfied the requirements of the Environmental Technical Specifications. Both preoperational and operational monitoring data were examined to test the usefulness of baseline information in evaluating impacts. This included an examination of the methods used to measure ecological, chemical, and physical parameters, and an assessment of sampling periodicity and sensitivity where appropriate data sets were available. From this type of analysis, deficiencies in both preoperational and operational monitoring programs may be identified and provide a basis for suggested improvement

  18. Impacts from new 50 MW wind power plant - Bogdnaci on the price of electrical energy in Macedonia

    International Nuclear Information System (INIS)

    Minovski, D.; Sarac, V.; Causevski, A.

    2012-01-01

    The paper presents the impact from the new planned wind power plant Bogdnaci on the price for the end users of electrical energy in Republic of Macedonia. In the next years, 50 MW wind power will be installed in the Macedonian electric power system. Production of electricity from wind power plants is unpredictable and of stochastic nature i.e. depends on the weather or the wind speed at the appropriate locations. Output of wind power plants is changing every minute, thus changing in the hourly level can be from 0 - 100%, even several times depending on the occurrence of winds. Changes in output of wind power plants, leads to increased demand for operational reserve in a power system. Preferential price of electrical energy from the wind power plants and increased operational reserve in the electric power system will have big impact on the final price of electrical energy in Republic of Macedonia. (Authors)

  19. Energy analysis and environmental impacts of a MSW oxy-fuel incineration power plant in China

    International Nuclear Information System (INIS)

    Tang, YuTing; Ma, XiaoQian; Lai, ZhiYi; Chen, Yong

    2013-01-01

    The entire life cycle of a municipal solid waste (MSW) oxy-fuel incineration power plant was evaluated using the method of life cycle assessment (LCA) to identify and quantify the fossil energy requirements and environmental impacts. The functional unit was 1000 kg (1 t) MSW. During the life cycle, the saving standard coal by electricity generation was more than diesel consumption, and the effect of soot and ashes was the greatest among all calculated categorization impacts. The total weighted resource consumption and total weighted environment potential of MSW oxy-fuel incineration were −0.37 mPR 90 (milli person equivalent) and −0.27 PET 2010 (person equivalent), better than MSW incineration with CO 2 capture via monoethanolamine (MEA) absorption. The sensitivity analysis showed that the electric power consumption of air separation unit (ASU) was the primary influencing parameter, and the influence of electric power consumption of CO 2 compressor was secondary, while transport distance had small influence. Overall, MSW oxy-fuel incineration technology has certain development potential with the increment of MSW power supply efficiency and development of ASU in the future. - Highlights: • Life cycle assessment of a MSW oxy-fuel incineration power plant is novel. • The MSW oxy-fuel incineration was better than the MSW incineration with MEA. • Among calculated impacts, the effect of soot and ashes was the greatest. • The electric power consumption of ASU was the primary influencing parameter

  20. How much is too little to detect impacts? A case study of a nuclear power plant.

    Science.gov (United States)

    Mayer-Pinto, Mariana; Ignacio, Barbara L; Széchy, Maria T M; Viana, Mariana S; Curbelo-Fernandez, Maria P; Lavrado, Helena P; Junqueira, Andrea O R; Vilanova, Eduardo; Silva, Sérgio H G

    2012-01-01

    Several approaches have been proposed to assess impacts on natural assemblages. Ideally, the potentially impacted site and multiple reference sites are sampled through time, before and after the impact. Often, however, the lack of information regarding the potential overall impact, the lack of knowledge about the environment in many regions worldwide, budgets constraints and the increasing dimensions of human activities compromise the reliability of the impact assessment. We evaluated the impact, if any, and its extent of a nuclear power plant effluent on sessile epibiota assemblages using a suitable and feasible sampling design with no 'before' data and budget and logistic constraints. Assemblages were sampled at multiple times and at increasing distances from the point of the discharge of the effluent. There was a clear and localized effect of the power plant effluent (up to 100 m from the point of the discharge). However, depending on the time of the year, the impact reaches up to 600 m. We found a significantly lower richness of taxa in the Effluent site when compared to other sites. Furthermore, at all times, the variability of assemblages near the discharge was also smaller than in other sites. Although the sampling design used here (in particular the number of replicates) did not allow an unambiguously evaluation of the full extent of the impact in relation to its intensity and temporal variability, the multiple temporal and spatial scales used allowed the detection of some differences in the intensity of the impact, depending on the time of sampling. Our findings greatly contribute to increase the knowledge on the effects of multiple stressors caused by the effluent of a power plant and also have important implications for management strategies and conservation ecology, in general.

  1. A quantitative impact analysis of sensor failures on human operator's decision making in nuclear power plants

    International Nuclear Information System (INIS)

    Seong, Poong Hyun

    2004-01-01

    In emergency or accident situations in nuclear power plants, human operators take important roles in generating appropriate control signals to mitigate accident situation. In human reliability analysis (HRA) in the framework of probabilistic safety assessment (PSA), the failure probabilities of such appropriate actions are estimated and used for the safety analysis of nuclear power plants. Even though understanding the status of the plant is basically the process of information seeking and processing by human operators, it seems that conventional HRA methods such as THERP, HCR, and ASEP does not pay a lot of attention to the possibilities of providing wrong information to human operators. In this paper, a quantitative impact analysis of providing wrong information to human operators due to instrument faults or sensor failures is performed. The quantitative impact analysis is performed based on a quantitative situation assessment model. By comparing the situation in which there are sensor failures and the situation in which there are not sensor failures, the impact of sensor failures can be evaluated quantitatively. It is concluded that the impact of sensor failures are quite significant at the initial stages, but the impact is gradually reduced as human operators make more and more observations. Even though the impact analysis is highly dependent on the situation assessment model, it is expected that the conclusions made based on other situation assessment models with be consistent with the conclusion made in this paper. (author)

  2. Nuclear power plant siting

    International Nuclear Information System (INIS)

    Sulkiewicz, M.; Navratil, J.

    The construction of a nuclear power plant is conditioned on territorial requirements and is accompanied by the disturbance of the environment, land occupation, population migration, the emission of radioactive wastes, thermal pollution, etc. On the other hand, a nuclear power plant makes possible the introduction of district heating and increases the economic and civilization activity of the population. Due to the construction of a nuclear power plant the set limits of negative impacts must not be exceeded. The locality should be selected such as to reduce the unfavourable effects of the plant and to fully use its benefits. The decision on the siting of the nuclear power plant is preceded by the processing of a number of surveys and a wide range of documentation to which the given criteria are strictly applied. (B.H.)

  3. Comparative study of radiological impact of nuclear power plant and coal-fired power plant: estimation of radiation dose to public from nuclear power plant and coal-fired power plant generation

    International Nuclear Information System (INIS)

    Umbara, Heru; Yatim, Sofyan

    1998-01-01

    Radiation impact assessment of Nuclear Power Plant and Coal-Fired Power Plant in Muria Penninsula was carried out. The computation of radionuclide releases to the atmosphere subjects to gaussian plume model, on the other hand, the radionuclide transfer model between environmental compartment (pathway) follow concentration factor methods. Both models are compiled in GENII-The Hanford Environmental Radiation Dosimetry Software System, which is used in the assessment. Most of all input data for GENII package are site specific, such as meteorological data, stack flow, stack height, population, local consumption except the transfer factor data are taken from the GENII package. The results show that during operation of NPP the maximal exposed individual received annual effective dose 150 nSv at 300 -700 m from the site toward east otherwise in operation of CPP the maximal exposed individual received annual effective dose 410 nSv in the same distance and direction. Both results of the maximal exposed individual received annual effective dose about 0,003 % and 0,008 % of whole body annual dose limit for members of public for NPP and CPP. (author)

  4. Technical solutions for mitigating adverse impacts on the environment implemented at Deva Thermal Power Plant

    International Nuclear Information System (INIS)

    Vaida, Victor; Egyed, Francisc; Manea, Laurean

    2004-01-01

    harmony with current and prospective environmental protection demands, especially for air protection. The facts herein presented clearly show the financial efforts so far made in operation as well as for prospective investments in further modernisation of the electrostatic precipitators and implementation of desulfurization plants, as top priorities. Another concern is the landscape and agricultural reinstatement of the ash disposal dumps that have been filled thus mitigating to the greatest extent possible the adverse effects that the existence of Deva Power Plant creates in its environment. A parallel ash recycling process has been initiated by marketing the dry ash to be used in the cement industry; the Power Plant collaborate with an important neighbouring cement producer for this purpose. The impact that the ash disposal dump has on the environment will be thus alleviated. The ash disposal area will also be reduced with the increase in the need of ash to be utilised on other commercial activities. The action plan for desulfurization, and gas emission mitigation in general, elaborated by Deva Power Plant has been integrated in a national average term programme involving all power industry polluting bodies. The flue gas desulfurization programme requires further modernisation of main power generation systems, primarily of burners to reduce NOx emission level below 500 mg/Nm 3 , and of electrostatic precipitators to reduce the powder emissions below 50 mg/Nm 3 . By adopting the wet limestone desulfurization method, SO 2 emissions into the air will be decreased from 50,000 tons annually to 4,500 tons and the desulfurization by-products will be marketed for the cement industry or infrastructure works

  5. Fuzzy logic utilization for the diagnosis of metallic loose part impact in nuclear power plant

    International Nuclear Information System (INIS)

    Oh, Y.-G.; Hong, H.-P.; Han, S.-J.; Chun, C.S.; Kim, B.-K.

    1996-01-01

    In consideration of the fuzzy nature of impact signals detected from the complex mechanical structures in a nuclear power plant under operation. Loose Part Monitoring System with a signal processing technique utilizing fuzzy logic is proposed. In the proposed Fuzzy Loose Part Monitoring System design, comprehensive relations among the impact signal features are taken into account in the fuzzy rule bases for the alarm discrimination and impact event diagnosis. Through the performance test with a mock-up facility, the proposed approach for the loose parts monitoring and diagnosis has been revealed to be effective not only in suppressing the false alarm generation but also in characterizing the metallic loose-part impact event, from the points of Possible Impacted-Area and Degree of Impact Magnitude

  6. The estimation economic impacts from severe accidents of a nuclear power plant

    International Nuclear Information System (INIS)

    Jeong, J. T.; Jeong, W. D.

    2001-01-01

    The severe accidents of a nuclear power plant may cause health effects in the exposed population and societal economic impacts or costs. Techniques to assess the consequences of an accident in terms of cost may be applied in studies on the design of plant safety features and in examining countermeasure options as part of emergency planning or in decision making after an accident. In this study, the costs resulting from the severe accidents of a nuclear power plant were estimated for the different combinations of source term release parameters and meteorological data. Also, the costs were estimated for the different scenarios considering seasonal characteristics of Korea. The results can be used as essential inputs in costs/benefit analysis and in developing optimum risk reduction strategies

  7. Environmental impact statement on the siting of nuclear power plants: scoping summary report

    International Nuclear Information System (INIS)

    1981-12-01

    The NRC staff has completed its scoping process for the Environmental Impact Statement for the revision of its regulations on the siting of nuclear power plants. The rulemaking and environmental review have been focused to concentrate on significant issues and alternatives and to delete items from the rulemaking on which it is not appropriate to proceed at this time. A brief discussion of the major comments is included

  8. Will nuclear power plant standardization reduce the licensing impact on construction

    International Nuclear Information System (INIS)

    Allen, J.M.; Bingham, W.G.; Keith, D.G.

    1976-01-01

    The NRC and the nuclear industry have been pursuing standardization quite vigorously in an effort to reduce the cost and schedule for the design and construction of nuclear power plants. The NRC is currently reviewing standard plant applications submitted under each of four standardization options. In addition, the NRC has published Standard Review Plans and Standard Technical Specifications. Although problems exist in the implementation of standardization and in areas unaffected by standardization, each of these standardization methods has the potential to reduce the licensing impact on construction

  9. Analysis of environmental impact phase in the life cycle of a nuclear power plant

    International Nuclear Information System (INIS)

    Hernandez del M, C.

    2015-01-01

    The life-cycle analysis covers the environmental aspects of a product throughout its life cycle. The focus of this study was to apply a methodology of life-cycle analysis for the environmental impact assessment of a nuclear power plant by analyzing international standards ISO 14040 and 14044. The methodology of life-cycle analysis established by the ISO 14044 standard was analyzed, as well as the different impact assessment methodologies of life cycle in order to choose the most appropriate for a nuclear power plant; various tools for the life-cycle analysis were also evaluated, as is the use of software and the use of databases to feed the life cycle inventory. The functional unit chosen was 1 KWh of electricity, the scope of analysis ranging from the construction and maintenance, disposal of spent fuel to the decommissioning of the plant, the manufacturing steps of the fuel were excluded because in Mexico is not done this stage. For environmental impact assessment was chosen the Recipe methodology which evaluates up to 18 impact categories depending on the project. In the case of a nuclear power plant were considered only categories of depletion of the ozone layer, climate change, ionizing radiation and formation of particulate matter. The different tools for life-cycle analysis as the methodologies of impact assessment of life cycle, different databases or use of software have been taken according to the modeling of environmental sensitivities of different regions, because in Mexico the methodology for life-cycle analysis has not been studied and still do not have all the tools necessary for the evaluation, so the uncertainty of the data supplied and results could be higher. (Author)

  10. Nuclear power plants

    International Nuclear Information System (INIS)

    1985-01-01

    Data concerning the existing nuclear power plants in the world are presented. The data was retrieved from the SIEN (Nuclear and Energetic Information System) data bank. The information are organized in table forms as follows: nuclear plants, its status and type; installed nuclear power plants by country; nuclear power plants under construction by country; planned nuclear power plants by country; cancelled nuclear power plants by country; shut-down nuclear power plants by country. (E.G.) [pt

  11. Calculation of coal power plant cost on agricultural and material building impact of emission

    International Nuclear Information System (INIS)

    Mochamad Nasrullah; Wiku Lulus Widodo

    2016-01-01

    Calculation for externally cost of Coal Power Plant (CPP) is very important. This paper is focus on CPP appear SO 2 impact on agricultural plant and material building. AGRIMAT'S model from International Atomic Energy Agency is model one be used to account environmental damage for air impact because SO 2 emission. Analysis method use Impact Pathways Assessment: Determining characteristic source, Exposure Response Functions (ERF), Impacts and Damage Costs, and Monetary Unit Cost. Result for calculate shows that SO 2 that issued CPP, if value of SO 2 is 19,3 μg/m3, damage cost begins valuably positive. It shows that the land around CPP has decrease prosperity, and it will disadvantage for agricultural plant. On material building, SO 2 resulting damage cost. The increase humidity price therefore damage cost on material building will increase cost. But if concentration SO 2 increase therefore damage cost that is appear on material building decrease. Expected this result can added with external cost on health impact of CPP. External cost was done at developed countries. If it is done at Indonesia, therefore generation cost with fossil as more expensive and will get implication on issue cut back gases greenhouse. On the other side, renewable energy and also alternative energy as nuclear have opportunity at national energy mix system. (author)

  12. Environmental Impact Report from Santa Rita Hydroelectric Power Plant (Minas Gerais State - Brazil): technical strategic for its elaboration

    International Nuclear Information System (INIS)

    Souza, J.A. de; Marques Neto, F.P.

    1989-01-01

    The steps for developing the technical strategies used on the elaboration of Environmental Impact Report from Santa Rita Hydroelectric Power Plant, Minas Gerais State, are described, including the influence area, technical requirements, impact identification, technical selection of mitigative measures, impact meaning and strategy for evaluating the identified impacts. (C.G.C.)

  13. Impact of extreme load requirements and quality assurance on nuclear power plant costs

    International Nuclear Information System (INIS)

    Stevenson, J.D.

    1993-01-01

    Definitive costs, applicable to nuclear power plant concrete structures, as a function of National Regulatory Requirements, standardization, the effect of extreme load design associated with both design basis accidents and extreme external events and quality assurance are difficult to develop since such effects are interrelated and not only differ widely from country to country, project to project but also vary in time. Table 1 shows an estimate of the of the overall plant cost effects of external event extreme load design on nuclear power plant design for the U.S -and selected foreign countries for which experience with LWRs exist- Germany is the most expensive primarily due to a military aircraft crash resistance. However, the German requirement for 4 safeguards trains rather than 2 and the containment design requirement to consider one Steam Generator blowdown concurrent with a RCS blowdown. This presentation will concentrate on the direct current impact extreme load design and quality assurance have on concrete structures, systems and components for nuclear plants. This presentation is considered timely due to the increased interest in the c potential backfit of Eastern European nuclear power stations of the WWER 440 and WWER 1000 types which typically did not consider the extreme loads identified in Table 1 and accident loads in Table 3 and quality assurance in Table 5 in their original design. Concrete structures in particular are highlighted because they typically form the last barrier to radioactive release from the containment and other Safety Related Structures

  14. Reviewing the impact of organisational factors on nuclear power plants safety. A Spanish research initiative

    International Nuclear Information System (INIS)

    Sola, R.; Garces, M.I.; Vaquero, C.; Sendio, F.; De la Cal, C.; Villadoniga, J.I.

    2000-01-01

    This paper describes the Spanish R and D project 'Development of methods to evaluate and model the impact of organisation on nuclear power plants safety' framed in an specific agreement among UNESA (Association of Spanish Utilities), CSN (Spanish Nuclear Safety Council) and CIEMAT (Research Centre for Energy, Environment and Technology), being this last one the institution in charge of the development of the research activities. The main goal of the proposed project is to increase the knowledge related the way nuclear power plants organise and manage their activities to enhance safety. This goal will be achieved through three perspectives: the development of preventive and corrective methodologies and the development of models to incorporate the organisation and management in the probabilistic safety assessment, PSA. (author)

  15. Simulation analysis of emissions trading impact on a non-utility power plant

    International Nuclear Information System (INIS)

    Imran, Kashif; Ahmad, Intesar; Hassan, Tehzeebul; Aslam, Muhammad Farooq; Ngan, Hon-Wing

    2009-01-01

    Non-utility power plants can competitively participate in open electricity market to reduce operational costs but in the absence of pollution charges or emissions trading such generators are tempted to cause greater pollution for profit maximization. This paper presents a solution that incorporates pollution charges for nitrogen oxides and sulphur dioxide emissions in line with existing national environmental quality standards and a new carbon dioxide emissions trading mechanism. A novel approach has been used for allocation of allowable emissions that favors efficiently fuelled and environmentally friendly operation for maximizing profit. Impact of proposed carbon trading on economical utilization of enormous indigenous coal reserves has been analyzed and determined to be acceptable. Software developed in this paper, harnessing Sequential Quadratic Programming capabilities of Matlab, is shown to be adequate simulation tool for various emissions trading schemes and an useful operational decision making tool for constrained non-linear optimization problem of a non-utility power plant. (author)

  16. Simulation analysis of emissions trading impact on a non-utility power plant

    Energy Technology Data Exchange (ETDEWEB)

    Imran, Kashif; Ahmad, Intesar [Department of Electrical Engineering, COMSATS Institute of IT, Lahore (Pakistan); Hassan, Tehzeebul [Department of Electrical Engineering, University of Engineering and Technology (UET), Lahore (Pakistan); Aslam, Muhammad Farooq [Department of Electrical Engineering, University of Management and Technology (UMT), Lahore (Pakistan); Ngan, Hon-Wing [Department of Electrical Engineering, Hong Kong Polytechnic University (China)

    2009-12-15

    Non-utility power plants can competitively participate in open electricity market to reduce operational costs but in the absence of pollution charges or emissions trading such generators are tempted to cause greater pollution for profit maximization. This paper presents a solution that incorporates pollution charges for nitrogen oxides and sulphur dioxide emissions in line with existing national environmental quality standards and a new carbon dioxide emissions trading mechanism. A novel approach has been used for allocation of allowable emissions that favors efficiently fuelled and environmentally friendly operation for maximizing profit. Impact of proposed carbon trading on economical utilization of enormous indigenous coal reserves has been analyzed and determined to be acceptable. Software developed in this paper, harnessing Sequential Quadratic Programming capabilities of Matlab, is shown to be adequate simulation tool for various emissions trading schemes and an useful operational decision making tool for constrained non-linear optimization problem of a non-utility power plant. (author)

  17. Comparison of environmental impact of waste disposal from fusion, fission and coal-fired power plants

    Energy Technology Data Exchange (ETDEWEB)

    Frey, Bruno [Fichtner GmbH und Co. KG, Stuttgart (Germany)

    2011-08-15

    The radiotoxic hazard of waste from fusion power plants has been compared with that of fission power and radioactive trace elements in coal ash within some research programs such as SEAFP and SEIF. Within another program, in 2005 a Power Plant Conceptual Study (PPCS) has been finalized investigating 4 fusion power plant models A to D. In this paper, the radiotoxicity of model B is compared with a fission power plant, concentrating on the production of wastes. The hazard of the respective masses of enriched uranium before use in a fission power plant and coal ash of a power plant generating the same amount of electricity are used as benchmarks. It is evident that the development of ingestion and inhalation hazard of the PPCS model B is different from the results of earlier studies because of different assumptions on material impurities and other constraints. An important aspect is the presence of actinides in fusion power plant waste. (orig.)

  18. Environmental impacts of coal mine and thermal power plant to the surroundings of Barapukuria, Dinajpur, Bangladesh.

    Science.gov (United States)

    Hossain, Md Nazir; Paul, Shitangsu Kumar; Hasan, Md Muyeed

    2015-04-01

    The study was carried out to analyse the environmental impacts of coal mine and coal-based thermal power plant to the surrounding environment of Barapukuria, Dinajpur. The analyses of coal, water, soil and fly ash were carried out using standard sample testing methods. This study found that coal mining industry and coal-based thermal power plant have brought some environmental and socio-economic challenges to the adjacent areas such as soil, water and air pollution, subsidence of agricultural land and livelihood insecurity of inhabitants. The pH values, heavy metal, organic carbon and exchangeable cations of coal water treated in the farmland soil suggest that coal mining deteriorated the surrounding water and soil quality. The SO4(2-) concentration in water samples was beyond the range of World Health Organisation standard. Some physico-chemical properties such as pH, conductivity, moisture content, bulk density, unburned carbon content, specific gravity, water holding capacity, liquid and plastic limit were investigated on coal fly ash of Barapukuria thermal power plant. Air quality data provided by the Barapukuria Coal Mining Company Limited were contradictory with the result of interview with the miners and local inhabitants. However, coal potentially contributes to the development of economy of Bangladesh but coal mining deteriorates the environment by polluting air, water and soil. In general, this study includes comprehensive baseline data for decision makers to evaluate the feasibility of coal power industry at Barapukuria and the coalmine itself.

  19. Efficiency and environmental impacts of electricity restructuring on coal-fired power plants

    Energy Technology Data Exchange (ETDEWEB)

    Chan, H. Ron [Maryland Univ., College Park, MD (United States). Dept. of Economics; Fell, Harrison [Colorado School of Mines, Golden, CO (United States). Division of Economics and Business; Lange, Ian [Stirling Univ. (United Kingdom). Division of Economics; Li, Shanjun [Cornell Univ., Ithaca, NY (United States). Dyson School of Applied Economics and Management

    2013-03-15

    We investigate the impacts of electricity market restructuring on fuel efficiency, utilization and, new to this area, cost of coal purchases among coal-fired power plants using a panel data set from 1991 to 2005. Our study focuses exclusively on coal-fired power plants and uses panel data covering several years after implementation of restructuring. The estimation compares how investor-owned (IOs) plants in states with restructuring changed their behavior relative to IOs in states without. Our analysis finds that restructuring led to: (1) a two percent improvement in fuel efficiency for IOs, (2) a ten percent decrease in unit cost of heat input, and (3) a lower capacity factor even after adjusting for cross-plant generation re-allocation due to cost reductions. Based on these estimates, back-of-the-envelope calculations find that restructuring has led to about 6.5 million dollars in annual cost savings or nearly 12 percent of operating expenses and up to a 7.6 percent emissions reduction per plant.

  20. Impact of coal-fired thermal power plant emissions on surrounding vegetative environment: a case study

    International Nuclear Information System (INIS)

    Soni, D.K.; Senger, C.B.S.

    1993-01-01

    Vegetative system around the thermal power plants are exposed to perpetual emissions of particulates as well as gaseous pollutants in various forms and nature. These emissions evidently are reflected in plant responses. In order to assess the response of natural flora of this region, 2 plant species, that is Mangifera indica and Holarrhina artidysentrica and certain pollution sensitive parameter, such as leaf area, pH of wash water of foliage and sugar content of the leaves were identified for this study. It was observed that the pH of wash solution of leaves was close to neutral in upstream locations and in polluted zone pH was acidic. Leaf area was higher in least polluted zone and lower in more polluted locations. Dust deposition on leaves was observed be lower in upstream locations and higher in influenced areas. Sugar variations in leaves showed negative impact in affected areas. (author). 9 refs., 5 tabs

  1. Impact of Nuclear Power and Desalination Plant Construction Toward National and East Java Economic

    International Nuclear Information System (INIS)

    Ratya-Anindita; Sriyana; M-Nasrullah

    2006-01-01

    The objective of this study is to determine the economic impacts of the construction of the nuclear power plant 2 x 100 MW(e) SMART type with desalination 4 x 10,000 m 3 which would conduct in years 2008 to 2017 in Madura Island, East Java. The predicted IO tables of 2008-2017 have been created by the application of dynamic IO projection. The economic impact was estimated through multiplier effect which covers direct impact and indirect impact as well as the induced effect. The expenditures of SMART nuclear power and desalination plant to the domestic contractors is estimated to amount to 88.2 million US dollar or 25.6 % of the whole expenditures. The total impact of the project to the national economy would be Rp. 6,329,347 million, Rp. 8,439,130 million, and Rp. 12,658,695 million for each scenario of the exchange rate as high as Rp. 7,500/US dollar, Rp. 10,000/US dollar, Rp. 15,000/US dollar, respectively for the scenario of dynamic growth. The total impact of the project to the provincial economy of East Java would be as much as Rp. 3,253,498 million, Rp. 4,337,997 million, and Rp. 6,506,995 million for each scenario of the exchange rate as high as Rp. 7,500/US dollar, Rp. 10,000/US dollar, Rp. 15,000/US dollar, respectively under the former scenario. Cumulative direct impact since pre-construction to construction period had been calculated as much as US dollar 101.8 million for sectors number 48.52 and 62. This have brought much impact on other sectors in national or provincial levels of economy. (author)

  2. Kansas Power Plants

    Data.gov (United States)

    Kansas Data Access and Support Center — The Kansas Power Plants database depicts, as point features, the locations of the various types of power plant locations in Kansas. The locations of the power plants...

  3. Distance matters. Assessing socioeconomic impacts of the Dukovany nuclear power plant in the Czech Republic: Local perceptions and statistical evidence

    Directory of Open Access Journals (Sweden)

    Frantál Bohumil

    2016-03-01

    Full Text Available The effect of geographical distance on the extent of socioeconomic impacts of the Dukovany nuclear power plant in the Czech Republic is assessed by combining two different research approaches. First, we survey how people living in municipalities in the vicinity of the power plant perceive impacts on their personal quality of life. Second, we explore the effects of the power plant on regional development by analysing long-term statistical data about the unemployment rate, the share of workers in the energy sector and overall job opportunities in the respective municipalities. The results indicate that the power plant has had significant positive impacts on surrounding communities both as perceived by residents and as evidenced by the statistical data. The level of impacts is, however, significantly influenced by the spatial and social distances of communities and individuals from the power plant. The perception of positive impacts correlates with geographical proximity to the power plant, while the hypothetical distance where positive effects on the quality of life are no longer perceived was estimated at about 15 km. Positive effects are also more likely to be reported by highly educated, young and middle-aged and economically active persons, whose work is connected to the power plant.

  4. Ageing of power plants socio-economical, sanitary and environmental impact

    International Nuclear Information System (INIS)

    Bataille, Ch.; Denner, M.; Vouilloux, F.; Foucher, L.; Serviere, M.; Vila d'Abadal Serra, M.

    2005-01-01

    The National Association of the local Commissions of Information (A.N.C.L.I.) presents a colloquium about the ageing of nuclear power plants. The different following points are presented. The life cycle of nuclear power plants and the new types of reactors. The ageing of power plants: stakes and perspectives for the French and world nuclear park. A power plant of 30 years is it sure? The role of the studies of ageing and the follow-up according to the age. Stop or continue to exploit a nuclear power plant: who decides, when and how. The socio-economic consequences of a stop of power plant: the Spanish experience. Ten-year visits of a power plant: the associative experience. 58 reactors today: how to assume their end of life and welcome equipments to come. (N.C.)

  5. Assessment of the impact of nuclear power plant construction and operation on small regions

    International Nuclear Information System (INIS)

    Johnson, M.H. Jr.

    1977-01-01

    This study addresses the problem of the comprehensive, quantitative evaluation of the environmental, economic, and social impacts of the construction and operation of nuclear power plant on a given region. A theoretical model of the regional impacts is constructed employing input-output methods that are extended to include ecologic as well as economic effects. Thus, the regional model explicitly incorporates environmental feedback as a consequence of economic activity. The model is then employed to estimate the impact of the construction and operation of a nuclear power facility on a small region in South Carolina. Measures of economic and environmental effects include estimates of changes in output, income, employment, local government revenue and expenditure, external costs of environmental decay, pollution loads, and common-property resource usage. Results indicate that, in the South Carolina case study, significant gains in social welfare accrued to the region due to the construction and operation of the nuclear power facility. Further, the theoretical method developed herein provides a comprehensive method of objectively assessing various types of impacts on a region as small as several contiguous counties or even a single county

  6. Environmental impact of coal industry and thermal power plants in India.

    Science.gov (United States)

    Mishra, U C

    2004-01-01

    Coal is the only natural resource and fossil fuel available in abundance in India. Consequently, it is used widely as a thermal energy source and also as fuel for thermal power plants producing electricity. India has about 90,000 MW installed capacity for electricity generation, of which more than 70% is produced by coal-based thermal power plants. Hydro-electricity contributes about 25%, and the remaining is mostly from nuclear power plants (NPPs). The problems associated with the use of coal are low calorific value and very high ash content. The ash content is as high as 55-60%, with an average value of about 35-40%. Further, most of the coal is located in the eastern parts of the country and requires transportation over long distances, mostly by trains, which run on diesel. About 70% oil is imported and is a big drain on India's hard currency. In the foreseeable future, there is no other option likely to be available, as the nuclear power programme envisages installing 20,000 MWe by the year 2020, when it will still be around 5% of the installed capacity. Hence, attempts are being made to reduce the adverse environmental and ecological impact of coal-fired power plants. The installed electricity generating capacity has to increase very rapidly (at present around 8-10% per annum), as India has one of the lowest per capita electricity consumptions. Therefore, the problems for the future are formidable from ecological, radio-ecological and pollution viewpoints. A similar situation exists in many developing countries of the region, including the People's Republic of China, where coal is used extensively. The paper highlights some of these problems with the data generated in the author's laboratory and gives a brief description of the solutions being attempted. The extent of global warming in this century will be determined by how developing countries like India manage their energy generation plans. Some of the recommendations have been implemented for new plants

  7. Flood/Typhoon vulnerability indicators of nuclear power plant in South Korea considering climate change impacts

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Gyu Min; Jun, Kyung Soo [Sungkyunkwan Univ., Suwon (Korea, Republic of); Chung, Eun Sung [Seoul National Univ of Science and technology, Seoul (Korea, Republic of); Min, Byung Il; Suh, Kyung Suk [KAERI, Daejeon (Korea, Republic of)

    2012-10-15

    The Republic of Korea lies in the principal course of the typhoon that is occurred to the Pacific Northwest. It has distinct monsoon wind, a rainy period from the East Asian Monsoon locally called 'Changma', typhoon, and while often heavy snowfalls in winter. It belongs to a relatively wet region due to much more precipitation than that of the world average. In the last 10 years, there frequently was a lot of damage due to flooding with typhoon. In particular, the damage was estimated at up to 5,000 billion KRW by the USA in 2002. Lately, after the 9.0 magnitude earthquake and resultant tsunami hit Japan on March 11, 2011, consecutively approached Typhoon Ro ke made a larger threat. Although it fortunately passed without significant impact. That is, not only typhoon and flood are one of a threat to nuclear power plant but also it could lead to overwhelming damage when it overlapped the other accident. Therefore, flood/typhoon vulnerability assessment could provide important information for the safety management of nuclear power plants. This study derived all the feasible indicators and their corresponding weights for a Flood/Typhoon Vulnerability Index (FTVI) to nuclear power plant considering climate change. In addition selection of the candidates and determination of their weights were estimated using a Delphi process, which is an advanced method for opinion measurement.

  8. Input-output model of regional environmental and economic impacts of nuclear power plants

    International Nuclear Information System (INIS)

    Johnson, M.H.; Bennett, J.T.

    1979-01-01

    The costs of delayed licensing of nuclear power plants calls for a more-comprehensive method of quantifying the economic and environmental impacts on a region. A traditional input-output (I-O) analysis approach is extended to assess the effects of changes in output, income, employment, pollution, water consumption, and the costs and revenues of local government disaggregated among 23 industry sectors during the construction and operating phases. Unlike earlier studies, this model uses nonlinear environmental interactions and specifies environmental feedbacks to the economic sector. 20 references

  9. Radioecological impact around the nuclear power plant - general public perception and facts

    International Nuclear Information System (INIS)

    Karunakara, N.

    2014-01-01

    Nuclear science and technology have contributed immensely to the overall societal developmental. Today, nuclear applications can be found in almost every social and economical sector, and in virtually every corner of the globe. Radiation and radioisotopes find wide applications in the fields of agriculture, food preservation, health care, industry, water management, etc. During the last five decades, India has established a strong technological base for producing safe and economic electricity through nuclear power, and in the use of radiation and radioisotopes for the benefit of society. Although people in general have been appreciating many of the above achievements, some of them are skeptical about the safety of nuclear reactors and impact on the environment. Large sections of society are also not aware of or are indifferent to many positive contributions that nuclear science and technology have made to everyday life. The Radioecology Research Laboratory of the University Science Instrumentation Centre, Mangalore University is engaged in frontline research studies on radioecology and radiation protection around the Kaiga Nuclear Power Plant in the west coast of India for the past 23 years. The general public perception on nuclear power and the results of the detailed scientific study on radioecology in the environment of a nuclear power plant are discussed

  10. Impact of Auxiliary Equipments Consumption on Electricity Generation Cost in Selected Power Plants of Pakistan

    Directory of Open Access Journals (Sweden)

    DILEEP KUMAR

    2017-04-01

    Full Text Available This study focuses on higher generation cost of electricity in selected TPPs (Thermal Power Plants in Sindh, Pakistan. It also investigates the energy consumed by the auxiliary equipment of the selected TPPs in Sindh, Pakistan. The AC (Auxiliary Consumption of selected TPPs is compared with that in UK and other developed countries. Results show that the AC in selected TPPs in Sindh, Pakistan exceeds the average AC of the TPPs situated in developed countries. Many energy conservation measures such as impeller trimming and de-staging, boiler feed pump, high voltage inverter, variable frequency drive, and upgrading the existing cooling tower fan blades with fiber reinforced plastic are discussed to overcome higher AC. This study shows that harnessing various available energy conservative measures the AC and unit cost can be reduced by 4.13 and 8.8%; also adverse environmental impacts can be mitigated. Results show that the unit cost of electricity can be reduced from Rs.20 to19/kWh in JTPP (Jamshoro Thermal Power Plant, Rs.9 to 8.8/kWh in GTPS (Gas Turbine Power Station Kotri and Rs. 11 to 10.27/ kWh in LPS (Lakhara Power Station. Thus, electricity production can be improved with the existing capacity, which will eventually assist to manage the current energy crisis and ensure its conservation

  11. Analysis and assessment of environmental impacts of small hydro power plant in Slovakia

    Science.gov (United States)

    Zeleňáková, M.; Fijko, R.; Remeňáková, I.

    2017-10-01

    Environmental impact assessment (EIA) is an important process that, prior to approval of the investment plan, can provide a detailed examination of the likely and foreseeable impacts of proposed construction activity on the environment. The objective of this paper is to apply a specific methodology for the analysis and evaluation of the environmental impacts of selected constructions, namely, small hydro power plant, using matrix of impacts. This analysis method is intended not only to increase the clarity and precision of the evaluation process, but also to align it with the requirements of the environmental impact assessment system. This modification should improve the reliability of the environmental impact assessment, and could moreover also be applied to other infrastructure projects. Comparison of alternatives and designation of the optimal variant are implemented based on selected criteria that objectively describe the characteristic lines of the planned alternatives of activity and their impact on the environment. The use of proper EIA procedures can help the decision-makers to formulate proper activities based on qualified decisions. The designed project in Spišské Bystré, Slovakia is used as a case study to clarify and exemplify the methodology and techniques.

  12. Impact Assessment of Atmospheric Dust on Foliage Pigments and Pollution Resistances of Plants Grown Nearby Coal Based Thermal Power Plants.

    Science.gov (United States)

    Hariram, Manisha; Sahu, Ravi; Elumalai, Suresh Pandian

    2018-01-01

    Plant species grown in the vicinity of thermal power plants (TPP) are one of the immobile substrates to sink most of the pollutants emitted from their stacks. The continuous exposure of toxic pollutants to these plants may affect their resistances and essential biochemical's concentrations. In the present study, we estimated the impact of dust load generated by a TPPs to plant's dust retention capacity and pollution resistances (APTI and API). The observed ambient air quality index (AQI) showed that the surroundings of TPPs are in the severe air pollution category. Observed AQI was greater than 100 in the surrounding area of TPP. The mean dust load on plant foliage was significantly greater in the polluted site compared with the control site: 4.45 ± 1.96 versus 1.38 ± 0.41 mg cm -2 . Nearby, TPP highest and lowest dust load were founded in F. benghalensis (7.58 ± 0.74) and F. religiosa (2.25 ± 0.12 mg cm -2 ) respectively. Analysis revealed the strong negative correlation between dust load and essential pigments of foliage, such as chlorophyll content, carotenoids, pH of foliage extract, and relative water content. Conversely, strong positive correlation was observed with the ascorbic acid content of plant species. Correlation and percentage change analysis in ascorbic acid content for the polluted site against the control site showed the adverse impact on plants due to dust load. Based on their responses to dust pollution, A. scholaris, P. longifolia, and M. indica were observed as most suitable plant species. Estimation of DRC, chlorophyll a/b ratio, APTI and API revealed the A. scholaris, F. benghalensis, P. longifolia, and M. indica as the most suitable plant species for green belt formation. The high gradation was obtained in A. scholaris, F. benghalensis, P. longifolia, and M. indica for opted parameters and showed their most suitability for green belt formation. Salient features of the present study provide useful evidences to estimate the

  13. Impact of power plant reliability on the choice of operating parameter values

    International Nuclear Information System (INIS)

    Kramer, R.A.

    1985-01-01

    In this thesis, the basic structure for the development of a methodology to evaluate the effect of operating parameters on plant availability and generating system economic dispatch optimization is described. Plant availability is determined by a fault free model. In this model historic, time dependent, component induced forced outage data is utilized as the basis for the calculation of projected plant forced outage rates. The influence of a particular fuel-cycle length at a specific generating station on the operational planning of a multi unit generating system is considered. The basis of the dispatch of units in this analysis is optimal economic operation, i.e., the minimization of the cost of reliability supplying electricity to the system's customers. As a result of the utilization of this technique, a simplified example that considers the choice between a 12- and 18-month fuel cycle length is evaluated in terms of its impact on plant availability, fuel cycle economics and overall optimal generating system economic dispatch. The reliability portion of this methodology is applied to a simplified representation of the recirculation system of a pressurized water reactor nuclear power plant to illustrate the analytic techniques

  14. Environmental impact of nuclear power plants. Proceedings of a conference held November 26-30, 1974, in Atlanta, Georgia

    International Nuclear Information System (INIS)

    Karam, R.A.; Morgan, K.Z.

    1976-01-01

    This conference served as a forum for experts, power industry executives and engineers, and Federal and state agencies' representatives to discuss and exchange information on the environmental effects of nuclear power plants. An objective of this meeting was to identify the necessary elements and legal requirements for environmental impact statements. Twenty-three papers were presented in six sessions: Plant Site Selection; Ecology; Radioactive Waste and Thermal Pollution; Standards and Guidelines in the Preparation of Environmental Impact Statements; Cost-Benefit Analysis; and Environmental Impact Studies of Various Power Reactors

  15. Environmental impact assessments of a fifth nuclear power plant unit in Finland

    International Nuclear Information System (INIS)

    Aurela, Jorma; Koivisto, Katarina

    2000-01-01

    This paper presents the results of president questionnaires and media monitoring of press cuttings concerned with siting of the new fifth in a row Finnish NPP. Two years ago both Fortum Power and Heat Oy and Teollisuuden Voima Oy (TVO) launched their Environmental impact assessment (EIA) procedures of a new nuclear power unit in Finland. The EIA procedures were launched to investigate the environmental impacts of a fifth nuclear power plant which possibly will be built in Loviisa or at Olkiluoto. In Finland there are four operating NPP units, two in Loviisa (Fortum) and two in Eurajoki, Olkiluoto (TVO). In the EIA procedure citizens and various associations and authorities have an opportunity to express their views on the matters related to the project. The Ministry of Trade and Industry (MTI) as the coordination authority arranges the organisation of the EIA hearings and the collection of statements and opinions. The EIA procedure in Finland takes place in two stages. The first stage i.e. the EIA programme describes the project and presents the plan on how the environmental effects are investigated and assessed. In the second stage the actual assessment of the environmental effects of the project will be submitted. Both Fortum and Teollisuuden Voima Oy (TVO) launched in spring 1998 their EIA procedures. The main alternatives are the Loviisa 3 project includes two plant type alternatives. The size of the plant is between 1000 and 1700 MWe, and the extension project of the Olkiluoto NPP to build a NPP unit of about 1000-1500 MWe at Olkiluoto. The EIA reports were submitted to the MTI in August 1999 and after that they were on display for two months for opinions and statements

  16. Fuel switching in power-plants: Modelling and impact on the analysis of energy projects

    International Nuclear Information System (INIS)

    Varympopiotis, G.; Tolis, A.; Rentizelas, A.

    2014-01-01

    Highlights: • The impact of fuel-switching in electricity generation is researched. • 15 Scenarios of fuel-technology combinations are compared using a computational model. • Fuel-switching results to higher yields compared to single-fuelled plants. • Plants with natural gas combined cycle and solid fuel supercritical boilers are optimal. • Fuel-switching, offers higher flexibility and security of fuel supply. - Abstract: In electricity markets, where conditions are uncertain, the choice of the best technology and the optimisation of production processes may not anymore be enough to ensure optimal investment yield of energy business plans. Providing some aspects of flexibility might enhance their financial performance; fuel switching may prove to be an alternative option, offering operational flexibility over time, as well as significant financial benefits. Traditional investment analysis methods are considered marginally useful to analyse this case. Instead, the recent tools of time-dependent investment analysis are more appropriate, since they are not inherently restricted to immediate, irreversible decisions. In the present work, a time-dependent computational model is presented and applied in the case study of the Greek Power Sector, in order to estimate the potential advantages of the fuel switching concept. Moreover, the optimal timing of switching is derived, to ensure increasing yields of an average-capacity power-plant. The results of the research indicate significant financial benefits anticipated in most scenarios from applying fuel switching, compared to single-fuelled electricity generation units. Security of fuel supply and enhanced flexibility may also be offered to the power plant since more than one technology and fuels may be engaged

  17. Radiological Impact Study of the Coal-Fired Power Plant of Narcea

    Energy Technology Data Exchange (ETDEWEB)

    Robles, B.; Baeza, A.; Mora, J. a.; Corbacho, J. a.; Trueba, C.; Guillen, J.; Rodriguez, Miralles, Y.

    2014-04-01

    Coal, fuel used in thermal power plants for electricity production, contains variable concentrations of naturally occurring radionuclides from natural disintegration series of {sup 2}38U, {sup 2}35U, {sup 2}32Th and also the 40K, which are enhanced in the wastes and coproducts due to the industrial process. For this reason, natural radionuclides which are part of the noncombustible fraction of coal, except those volatiles which incorporate directly to the flue gases, concentrates and are partitioned between fly ashes and bottom ashes. This enhancement could cause, to the workers of the installation and to members of the public around the plant, an increase in the exposure which should be assessed under the radiation protection point of view. Present report collect the results obtained from a screening assessment of the radiological impact derived from the normal operation of the Narcea coal-fired power plant. The project where this assessment was performed is part of a bigger project which is jointly developed by the Unit of Radiation Protection of the Public and the Environment (UPRPYMA) of CIEMAT and the Environmental Radioactivity Laboratory of the Extremadura University (LARUEX) in agreement with the Spanish Association of the Electrical Industry (ENUSA). (Author)

  18. Quantitative evaluation of the impact of human reliability in risk assessment for nuclear power plants

    International Nuclear Information System (INIS)

    Samanta, P.K.

    1981-01-01

    The role of human beings in the safe operation of a nuclear power plant has been a matter of concern. This study describes methods for the quantitative description of that role and its impact on the risk from nuclear power plants. The impact of human errors was calculated by observing the changes in risk parameters, such as core melt probability, release category probabilities, accident sequence probabilities and system unavailabilities due to changes in the contribution to unavailablity of human errors, within the framework of risk assessment methodology. It was found that for operational pressurized water reactors the opportunity for reduction in core melt probability by reducing the human error rates without simultaneous reduction of hardware failures is limited, but that core melt probability would significantly increase as human error rates increased. More importantly, most of the dominant accident sequences showed a significant increase in their probabilities with an increase in human error rates. Release categories resulting in high consequences showed a much larger sensitivity to human errors than categories resulting in low consequences. A combination of structural importance and reliability importance measure was used to describe the importance of individual errors

  19. Radiological impact assessment of coal and nuclear base power plants in India

    International Nuclear Information System (INIS)

    Ramachandran, T.V.

    2007-01-01

    Environmental problems concerned with the use of coal as a fuel in thermal power plants (TPS) is due to the production of fly ash. Coal contains tracers of primordial radionuclide and its burning is one of the sources of technologically enhanced exposure from natural radionuclides. When it is burnt in TPSs, the fly ash, emitted through the stack is enriched in radionuclide and so combustion of coal on a large scale for thermal power generation assumes importance. Many of these TPSs are located in thickly populated areas. Radioactivity content of the coal from the coalfields of eastern parts of the country is found to be higher than that of other coalfields. In India coal combustion accounts nearly 73% of the total installed capacity for power generation. A sample study was carried out by this center on coal and fly ash samples collected from more than 35 TPS spread all over the country with a total installed capacity of 10000 MW(e), for their-radioactivity content. Radiation doses to the population residing within 90 km radius of each TPS have been computed. Besides another set of 15 TPSs were studied for thermal pollution emission and trace element concentration. Operation of these TPSs has resulted in effective dose commitments from doses to bones, lungs and thyroid of 200 man-Sv.y -1 and from doses to the whole body, of 70 man-Sv.y -1 . Dose commitments to the population living within 90 km radius of the TPSs and NPPs in India have been computed and have been compared. Attempt is made to assess the inhalation dose from the radioactivity released from a typical 500 MW(e) TPS and its impact related to chemical pollutants. Impact in terms of Environmental Quality Index (EQI) due to conventional pollutions have been computed and compared with those due to the nuclear power plants (NPPs). Paper gives the summary of the study. (author)

  20. Evaluation of water quality parameters and associated environmental impact at nuclear power plant sites

    International Nuclear Information System (INIS)

    Joshi, M.L.; Hegde, A.G.

    2005-01-01

    The Nuclear Power Plants use a large quantity of water for the purpose of cooling the turbine condenser. The heated effluents are discharged to aquatic environment by means of once through cooling wherever large water bodies like seacoast or fresh water reservoir are available. The quality of water bodies are important for the growth and biodiversity of aquatic organisms. Several environmental factors like Temperature pH, Dissolved Oxygen have a bearing on the life cycle of aquatic organisms. The paper describes the evaluation of water quality parameters at the two typical sites one on the sea coast (Tarapur) and other at inland site Kaiga and discusses the environmental impact due to discharge to aquatic environment. It is found that the environmental impacts due to both heated effluents and radioactivity are insignificant. The water quality parameters are found to be well within the prescribed standards. (author)

  1. Impact of environmental cost on economics of thermal power plant. Paper no. IGEC-1-007

    International Nuclear Information System (INIS)

    Chandra, H.; Kaushik, S.C.; Chandra, A.

    2005-01-01

    Cost analysis per unit of power generation have been performed for coal based thermal power plant situated in Dadri (UP) for Indian and imported coal from Australia and America. In our study it has been found that it is better to use imported coal in Indian thermal power plants with advantages like low environmental, investment and total cost per unit of power generation. The effect of percent excess air and plant load factor on total cost per unit of power generation is also analyzed. (author)

  2. MERCURY EMISSIONS FROM COAL FIRED POWER PLANTS LOCAL IMPACTS ON HUMAN HEALTH RISK.

    Energy Technology Data Exchange (ETDEWEB)

    SULLIVAN, T.M.; BOWERMAN, B.; ADAMS, J.; LIPFERT, F.; MORRIS, S.M.; BANDO, A.; PENA, R.; BLAKE, R.

    2005-12-01

    A thorough quantitative understanding of the processes of mercury emissions, deposition, and translocation through the food chain is currently not available. Complex atmospheric chemistry and dispersion models are required to predict concentration and deposition contributions, and aquatic process models are required to predict effects on fish. However, there are uncertainties in all of these predictions. Therefore, the most reliable method of understanding impacts of coal-fired power plants on Hg deposition is from empirical data. A review of the literature on mercury deposition around sources including coal-fired power plants found studies covering local mercury concentrations in soil, vegetation, and animals (fish and cows). There is strong evidence of enhanced local deposition within 3 km of the chlor-alkali plants, with elevated soil concentrations and estimated deposition rates of 10 times background. For coal-fired power plants, the data show that atmospheric deposition of Hg may be slightly enhanced. On the scale of a few km, modeling suggests that wet deposition may be increased by a factor of two or three over background. The measured data suggest lower increases of 15% or less. The effects of coal-fired plants seem to be less than 10% of total deposition on a national scale, based on emissions and global modeling. The following summarizes our findings from published reports on the impacts of local deposition. In terms of excesses over background the following increments have been observed within a few km of the plant: (1) local soil concentration Hg increments of 30%-60%, (2) sediment increments of 18-30%, (3) wet deposition increments of 11-12%, and (4) fish Hg increments of about 5-6%, based on an empirical finding that fish concentrations are proportional to the square root of deposition. Important uncertainties include possible reductions of RGM to Hg{sub 0} in power plant plumes and the role of water chemistry in the relationship between Hg

  3. Mathematical Modeling – The Impact of Cooling Water Temperature Upsurge on Combined Cycle Power Plant Performance and Operation

    Science.gov (United States)

    Indra Siswantara, Ahmad; Pujowidodo, Hariyotejo; Darius, Asyari; Ramdlan Gunadi, Gun Gun

    2018-03-01

    This paper presents the mathematical modeling analysis on cooling system in a combined cycle power plant. The objective of this study is to get the impact of cooling water upsurge on plant performance and operation, using Engineering Equation Solver (EES™) tools. Power plant installed with total power capacity of block#1 is 505.95 MWe and block#2 is 720.8 MWe, where sea water consumed as cooling media at two unit condensers. Basic principle of analysis is heat balance calculation from steam turbine and condenser, concern to vacuum condition and heat rate values. Based on the result shown graphically, there were impact the upsurge of cooling water to increase plant heat rate and vacuum pressure in condenser so ensued decreasing plant efficiency and causing possibility steam turbine trip as back pressure raised from condenser.

  4. IMPACT OF THE COLD END OPERATING CONDITIONS ON ENERGY EFFICIENCY OF THE STEAM POWER PLANTS

    Directory of Open Access Journals (Sweden)

    Slobodan Laković

    2010-01-01

    Full Text Available The conventional steam power plant working under the Rankine Cycle and the steam condenser as a heat sink and the steam boiler as a heat source have the same importance for the power plant operating process. Energy efficiency of the coal fired power plant strongly depends on its turbine-condenser system operation mode. For the given thermal power plant configuration, cooling water temperature or/and flow rate change generate alterations in the condenser pressure. Those changes have great influence on the energy efficiency of the plant. This paper focuses on the influence of the cooling water temperature and flow rate on the condenser performance, and thus on the specific heat rate of the coal fired plant and its energy efficiency. Reference plant is working under turbine-follow mode with an open cycle cooling system. Analysis is done using thermodynamic theory, in order to define heat load dependence on the cooling water temperature and flow rate. Having these correlations, for given cooling water temperature it is possible to determine optimal flow rate of the cooling water in order to achieve an optimal condensing pressure, and thus, optimal energy efficiency of the plant. Obtained results could be used as useful guidelines in improving existing power plants performances and also in design of the new power plants.

  5. Power Watch - A global, open database of power plants that supports research on climate, water and air pollution impact of the global power sector.

    Science.gov (United States)

    Friedrich, J.; Kressig, A.; Van Groenou, S.; McCormick, C.

    2017-12-01

    Challenge The lack of transparent, accessible, and centralized power sector data inhibits the ability to research the impact of the global power sector. information gaps for citizens, analysts, and decision makers worldwide create barriers to sustainable development efforts. The need for transparent, accessible, and centralized information is especially important to enhance the commitments outlined in the recently adopted Paris Agreement and Sustainable Development Goals. Offer Power Watch will address this challenge by creating a comprehensive, open-source platform on the world's power systems. The platform hosts data on 85% of global installed electrical capacity and for each power plant will include data points on installed capacity, fuel type, annual generation, commissioning year, with more characteristics like emissions, particulate matter, annual water demand and more added over time. Most of the data is reported from national level sources, but annual generation and other operational characteristiscs are estimated via Machine Learning modeling and remotely sensed data when not officially reported. In addition, Power Watch plans to provide a suite of tools that address specific decision maker needs, such as water risk assessments and air pollution modeling. Impact Through open data, the platform and its tools will allow reserachers to do more analysis of power sector impacts and perform energy modeling. It will help catalyze accountability for policy makers, businesses, and investors and will inform and drive the transition to a clean energy future while reaching development targets.

  6. Information technology impact on nuclear power plant documentation. Report prepared within the framework of the International Working Group on Nuclear Power Plant Control and Instrumentation

    International Nuclear Information System (INIS)

    2002-04-01

    As the majority of the nuclear power plants (NPPs) in the world were designed and constructed about twenty to forty years ago, these older power plants may have shortcomings in documentation on construction, commissioning, operations, maintenance, or decommissioning. Therefore, facility documentation does not always reflect actual plant status after years of plant operation, modification, and maintenance. To deal with these shortcomings, computer and information technologies that provide sophisticated and modern design tools as well as information processing and storage facilities can offer dramatic innovation from paper-centric documentation towards data-centric documentation. This report addresses all aspects of documentation associated with various life-cycle phases of NPPs and the information technology (IT) that are relevant to the documentation process. It also provides a guide for planning, designing, and executing an IT documentation project. Examples are given to demonstrate successful implementations at plants. Finally, it discusses the issues related to the application of the IT in NPPs and the trends for applications of the IT at NPPs as well as the technology itself. It is recognized that this can also improve configuration management. reliability of data, quality of personnel work, and ultimately plant performance reliability and safety. The aspects of using the IT for NPP documentation are closely related to configuration management at NPPs. The report consists of nine sections, a reference section, and five additional appendices. The development of this report which was initiated by the IAEA International Working Group on Nuclear Power Plant Control and Instrumentation (IWG-NPPCI). It is the result of a series of consultants meetings held by the IAEA in Vienna (October 1999, November 2000). It was prepared with the participation and contributions of experts from Canada, Germany, Norway, Sweden, and the United States of America. In addition, a

  7. Information technology impact on nuclear power plant documentation. Report prepared within the framework of the International Working Group on Nuclear Power Plant Control and Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-04-01

    As the majority of the nuclear power plants (NPPs) in the world were designed and constructed about twenty to forty years ago, these older power plants may have shortcomings in documentation on construction, commissioning, operations, maintenance, or decommissioning. Therefore, facility documentation does not always reflect actual plant status after years of plant operation, modification, and maintenance. To deal with these shortcomings, computer and information technologies that provide sophisticated and modern design tools as well as information processing and storage facilities can offer dramatic innovation from paper-centric documentation towards data-centric documentation. This report addresses all aspects of documentation associated with various life-cycle phases of NPPs and the information technology (IT) that are relevant to the documentation process. It also provides a guide for planning, designing, and executing an IT documentation project. Examples are given to demonstrate successful implementations at plants. Finally, it discusses the issues related to the application of the IT in NPPs and the trends for applications of the IT at NPPs as well as the technology itself. It is recognized that this can also improve configuration management. reliability of data, quality of personnel work, and ultimately plant performance reliability and safety. The aspects of using the IT for NPP documentation are closely related to configuration management at NPPs. The report consists of nine sections, a reference section, and five additional appendices. The development of this report which was initiated by the IAEA International Working Group on Nuclear Power Plant Control and Instrumentation (IWG-NPPCI). It is the result of a series of consultants meetings held by the IAEA in Vienna (October 1999, November 2000). It was prepared with the participation and contributions of experts from Canada, Germany, Norway, Sweden, and the United States of America. In addition, a

  8. Impact of drought on U.S. steam electric power plant cooling water intakes and related water resource management issues.

    Energy Technology Data Exchange (ETDEWEB)

    Kimmell, T. A.; Veil, J. A.; Environmental Science Division

    2009-04-03

    This report was funded by the U.S. Department of Energy's (DOE's) National Energy Technology Laboratory (NETL) Existing Plants Research Program, which has an energy-water research effort that focuses on water use at power plants. This study complements their overall research effort by evaluating water availability at power plants under drought conditions. While there are a number of competing demands on water uses, particularly during drought conditions, this report focuses solely on impacts to the U.S. steam electric power plant fleet. Included are both fossil-fuel and nuclear power plants. One plant examined also uses biomass as a fuel. The purpose of this project is to estimate the impact on generation capacity of a drop in water level at U.S. steam electric power plants due to climatic or other conditions. While, as indicated above, the temperature of the water can impact decisions to halt or curtail power plant operations, this report specifically examines impacts as a result of a drop in water levels below power plant submerged cooling water intakes. Impacts due to the combined effects of excessive temperatures of the returned cooling water and elevated temperatures of receiving waters (due to high ambient temperatures associated with drought) may be examined in a subsequent study. For this study, the sources of cooling water used by the U.S. steam electric power plant fleet were examined. This effort entailed development of a database of power plants and cooling water intake locations and depths for those plants that use surface water as a source of cooling water. Development of the database and its general characteristics are described in Chapter 2 of this report. Examination of the database gives an indication of how low water levels can drop before cooling water intakes cease to function. Water level drops are evaluated against a number of different power plant characteristics, such as the nature of the water source (river vs. lake or reservoir

  9. Pilot plant assessment of blend properties and their impact on critical power plant components

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-10-01

    A series of tests were performed to determine the effects of blending eastern bituminous coals with western subbituminous coals on utility boiler operation. Relative to the baseline bituminous coal, the testing reported here indicated that there were significant impacts to boiler performance due to the blending of the eastern and western coals. Results indicated that fuel blending can be used to adequately control flue gas emissions of both SO{sub 2} and NO{sub x} at the expense of reduced milling efficiency, increased sootblowing in the high-temperature and low-temperature regions of the boiler and, to a lesser extent, decreased collection efficiency for an electrostatic precipitator. The higher reactivity of the subbituminous coal increased the overall combustion efficiency, which may tend to decrease the impact of milling efficiency losses. The extent of these impacts was directly related to the percentage of subbituminous coal in the blends. At the lowest blend ratios of subbituminous coal, the impacts were greatly reduced.

  10. Measures against the adverse impact of natural wind on air-cooled condensers in power plant

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    The natural wind plays disadvantageous roles in the operation of air-cooled steam condensers in power plant.It is of use to take various measures against the adverse effect of wind for the performance improvement of air-cooled condensers.Based on representative 2×600 MW direct air-cooled power plant,three ways that can arrange and optimize the flow field of cooling air thus enhance the heat transfer of air-cooled condensers were proposed.The physical and mathematical models of air-cooled condensers with various flow leading measures were presented and the flow and temperature fields of cooling air were obtained by CFD simulation.The back pressures of turbine were calculated for different measures on the basis of the heat transfer model of air-cooled condensers.The results show that the performance of air-cooled condensers is improved thus the back pressure of turbine is lowered to some extent by taking measures against the adverse impact of natural wind.

  11. Evaluation of gas emissions and environmental impact of a Cuban thermal power plant

    International Nuclear Information System (INIS)

    Colas Aroche, Juan Alberto; Alvarez Hernandez, Orlando H; Fuentes Quevedo, Eduardo; Teutelo Nunnez, Raisa

    2006-01-01

    The present work shows the results obtained in the characterization of gas emissions and the impact of two fire-tube boilers in a Cuban thermal power plant. The results of the SO 2 and NO X sampling were collected in specific solutions for each pollutant. The sampling of suspended particulates in chimneys/pipes/stacks was made by collecting them in a filterholder for their analysis by means of the gravimetric method. Flow measurements were also made by using pressure sensors of Pilot tube-type speedometers. The dispersion modelling of pollutants poured out of the chimneys was developed running the program for the concentration calculation from continuous industrial sources and following the methodology approved by the Cuban standard according to Berliand model. The authors conclude that when burning national crude oil in the studied boilers, sulphur dioxide concentrations and suspended particulates are higher than the internationally standardized level

  12. The estimation of economic impacts resulting from the severe accidents of a nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Jong Tae; Jung, Won dea

    2001-03-01

    The economic impacts resulting from the severe accidents of a nuclear power plant were estimated for the different combinations of a release parameters and metrorological data. According to the cost estimation for the basic scenarios, the population dependent cost is dominant. The cost for the protective actions such as evacuation and relocation have a small portion in the total cost and show little variation from scenario to scenario. The economic cost estimation for the seasonal scenarios show very similar trend as that for the basic scenarios. There are little or small variation in the economic cost for the different scenarios for each season except for the season-5 scenario. The health effect value shows maximum in Summer and minimum in Fall. On the contrast, the economic cost shows maximum in Fall and minimum in Summer. The result will be used as basic data in the establishment of effective emergency response and in the cost/benefit analysis in developing optimum risk reduction strategies.

  13. The estimation of economic impacts resulting from the severe accidents of a nuclear power plant

    International Nuclear Information System (INIS)

    Jeong, Jong Tae; Jung, Won dea

    2001-03-01

    The economic impacts resulting from the severe accidents of a nuclear power plant were estimated for the different combinations of a release parameters and metrorological data. According to the cost estimation for the basic scenarios, the population dependent cost is dominant. The cost for the protective actions such as evacuation and relocation have a small portion in the total cost and show little variation from scenario to scenario. The economic cost estimation for the seasonal scenarios show very similar trend as that for the basic scenarios. There are little or small variation in the economic cost for the different scenarios for each season except for the season-5 scenario. The health effect value shows maximum in Summer and minimum in Fall. On the contrast, the economic cost shows maximum in Fall and minimum in Summer. The result will be used as basic data in the establishment of effective emergency response and in the cost/benefit analysis in developing optimum risk reduction strategies

  14. Analysis of mercury in rock varnish samples in areas impacted by coal-fired power plants

    International Nuclear Information System (INIS)

    Nowinski, Piotr; Hodge, Vernon F.; Gerstenberger, Shawn; Cizdziel, James V.

    2013-01-01

    Rock varnish is a manganese–iron rich coating that forms on rocks, most often in arid climates. To assess its utility as an environmental monitor of mercury contamination, cold vapor atomic absorption spectrometry (CVAAS) was used for analysis. Samples were collected in the fallout patterns of two coal-fired power plants in southern Nevada: the defunct Mohave Power Plant (MPP) and the operating Reid Gardner Power Plant (RGPP). The resultant Hg concentrations in rock varnishes were plotted as a function of the distance from each power plant. The highest concentrations of Hg occurred at locations that suggest the power plants are the main source of pollutants. In addition, past tracer plume studies carried out at MPP show that the highest tracer concentrations coincide with the highest rock varnish Hg concentrations. However, additional samples are required to further demonstrate that power plants are indeed the sources of mercury in varnishes. -- Highlights: •We analyze desert varnish samples collected in the fallout patterns of two coal-fired and analyzed for Hg by CVAA. •The resultant Hg concentrations in the desert varnish samples were plotted as a function of the distance from each power plant. •The highest concentrations of Hg occurred at locations that suggest the power plants are the main source of pollutants. •Data indicate the utility of desert varnish as a passive environmental monitor for Hg atmospheric pollution. -- Cold vapor atomic absorption spectrometry (CVAAS) was used for analysis of mercury in varnished rocks collected in the fallout zones of two coal-fired power plants

  15. The Net Climate Impact of Coal-Fired Power Plant Emissions

    Science.gov (United States)

    Shindell, D.; Faluvegi, G.

    2010-01-01

    Coal-fired power plants influence climate via both the emission of long-lived carbon dioxide (CO2) and short-lived ozone and aerosol precursors. Using a climate model, we perform the first study of the spatial and temporal pattern of radiative forcing specifically for coal plant emissions. Without substantial pollution controls, we find that near-term net global mean climate forcing is negative due to the well-known aerosol masking of the effects of CO2. Imposition of pollution controls on sulfur dioxide and nitrogen oxides leads to a rapid realization of the full positive forcing from CO2, however. Long-term global mean forcing from stable (constant) emissions is positive regardless of pollution controls. Emissions from coal-fired power plants until 1970, including roughly 1/3 of total anthropogenic CO2 emissions, likely contributed little net global mean climate forcing during that period though they may have induce weak Northern Hemisphere mid-latitude (NHml) cooling. After that time many areas imposed pollution controls or switched to low sulfur coal. Hence forcing due to emissions from 1970 to 2000 and CO2 emitted previously was strongly positive and contributed to rapid global and especially NHml warming. Most recently, new construction in China and India has increased rapidly with minimal application of pollution controls. Continuation of this trend would add negative near-term global mean climate forcing but severely degrade air quality. Conversely, following the Western and Japanese pattern of imposing air quality pollution controls at a later time could accelerate future warming rates, especially at NHmls. More broadly, our results indicate that due to spatial and temporal inhomogeneities in forcing, climate impacts of multi-pollutant emissions can vary strongly from region to region and can include substantial effects on maximum rate-of-change, neither of which are captured by commonly used global metrics. The method we introduce here to estimate

  16. Seismic response prediction for cabinets of nuclear power plants by using impact hammer test

    Energy Technology Data Exchange (ETDEWEB)

    Koo, Ki Young [Department of Civil and Structural Engineering, University of Sheffield, Sheffield (United Kingdom); Gook Cho, Sung [JACE KOREA, Gyeonggi-do (Korea, Republic of); Cui, Jintao [Department of Civil Engineering, Kunsan National University, Jeonbuk (Korea, Republic of); Kim, Dookie, E-mail: kim2kie@kunsan.ac.k [Department of Civil Engineering, Kunsan National University, Jeonbuk (Korea, Republic of)

    2010-10-15

    An effective method to predict the seismic response of electrical cabinets of nuclear power plants is developed. This method consists of three steps: (1) identification of the earthquake-equivalent force based on the idealized lumped-mass system of the cabinet, (2) identification of the state-space equation (SSE) model of the system using input-output measurements from impact hammer tests, and (3) seismic response prediction by calculating the output of the identified SSE model under the identified earthquake-equivalent force. A three-dimensional plate model of cabinet structures is presented for the numerical verification of the proposed method. Experimental validation of the proposed method is carried out on a three-story frame which represents the structure of a cabinet. The SSE model of the frame is accurately identified by impact hammer tests with high fitness values over 85% of the actual frame characteristics. Shaking table tests are performed using El Centro, Kobe, and Northridge earthquakes as input motions and the acceleration responses are measured. The responses of the model under the three earthquakes are predicted and then compared with the measured responses. The predicted and measured responses agree well with each other with fitness values of 65-75%. The proposed method is more advantageous over other methods that are based on finite element (FE) model updating since it is free from FE modeling errors. It will be especially effective for cabinet structures in nuclear power plants where conducting shaking table tests may not be feasible. Limitations of the proposed method are also discussed.

  17. Preliminary evaluation of aircraft impact on a near term nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Frano, R. Lo, E-mail: rosa.lofrano@ing.unipi.it [Department of Mechanical, Nuclear and Production Engineering, University of PISA, L.go L. Lazzarino 2, via Diotisalvi, no. 2-56126 Pisa (Italy); Forasassi, G. [Department of Mechanical, Nuclear and Production Engineering, University of PISA, L.go L. Lazzarino 2, via Diotisalvi, no. 2-56126 Pisa (Italy)

    2011-12-15

    Highlights: Black-Right-Pointing-Pointer The effects of military/civilian airplanes crash in a NPP were evaluated. Black-Right-Pointing-Pointer We adequately simulated the global response and safety margin of an SMR reactor. Black-Right-Pointing-Pointer The analyses allowed to represent the progressive failure/damaging processes. Black-Right-Pointing-Pointer The outer containment seemed to suffer some localized penetration and spalling. Black-Right-Pointing-Pointer The results highlighted the plant integrity is ensured despite the impact damages. - Abstract: For the assessment of the safety and durability of a nuclear power plant (NPP), the containment building behaviour shall be evaluated, under various service and extreme conditions, both natural or produced by natural accident or vicious man activities, like September 2001 jet aircraft crashes. The aim of this paper is to preliminary evaluate the effects and consequences of the energy transmitted to the outer containment walls (according to the international safety and design code guidelines, as NRC or IAEA ones) due to a military or civil aircraft impact into a nuclear plant, considered as a 'beyond design basis' event. To perform reliable analysis of such a large-scale structure and determine the structural effects of the propagation of this types of impulsive loads (response of containment structure), a realistic but still feasible numerical model with suitable materials characteristics were used by means of which relevant physical phenomena are reflected. Moreover a sensitivity analysis has also been carried out considering the effects of different containment wall thickness and reinforced/prestressed concrete features. The obtained results were analysed to check the NPP containment strength margins.

  18. Root causes and impacts of severe accidents at large nuclear power plants.

    Science.gov (United States)

    Högberg, Lars

    2013-04-01

    The root causes and impacts of three severe accidents at large civilian nuclear power plants are reviewed: the Three Mile Island accident in 1979, the Chernobyl accident in 1986, and the Fukushima Daiichi accident in 2011. Impacts include health effects, evacuation of contaminated areas as well as cost estimates and impacts on energy policies and nuclear safety work in various countries. It is concluded that essential objectives for reactor safety work must be: (1) to prevent accidents from developing into severe core damage, even if they are initiated by very unlikely natural or man-made events, and, recognizing that accidents with severe core damage may nevertheless occur; (2) to prevent large-scale and long-lived ground contamination by limiting releases of radioactive nuclides such as cesium to less than about 100 TBq. To achieve these objectives the importance of maintaining high global standards of safety management and safety culture cannot be emphasized enough. All three severe accidents discussed in this paper had their root causes in system deficiencies indicative of poor safety management and poor safety culture in both the nuclear industry and government authorities.

  19. Root Causes and Impacts of Severe Accidents at Large Nuclear Power Plants

    International Nuclear Information System (INIS)

    Hoegberg, Lars

    2013-01-01

    The root causes and impacts of three severe accidents at large civilian nuclear power plants are reviewed: the Three Mile Island accident in 1979, the Chernobyl accident in 1986, and the Fukushima Daiichi accident in 2011. Impacts include health effects, evacuation of contaminated areas as well as cost estimates and impacts on energy policies and nuclear safety work in various countries. It is concluded that essential objectives for reactor safety work must be: (1) to prevent accidents from developing into severe core damage, even if they are initiated by very unlikely natural or man-made events, and, recognizing that accidents with severe core damage may nevertheless occur; (2) to prevent large-scale and long lived ground contamination by limiting releases of radioactive nuclides such as cesium to less than about 100 TBq. To achieve these objectives the importance of maintaining high global standards of safety management and safety culture cannot be emphasized enough. All three severe accidents discussed in this paper had their root causes in system deficiencies indicative of poor safety management and poor safety culture in both the nuclear industry and government authorities

  20. Root Causes and Impacts of Severe Accidents at Large Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Hoegberg, Lars

    2013-04-15

    The root causes and impacts of three severe accidents at large civilian nuclear power plants are reviewed: the Three Mile Island accident in 1979, the Chernobyl accident in 1986, and the Fukushima Daiichi accident in 2011. Impacts include health effects, evacuation of contaminated areas as well as cost estimates and impacts on energy policies and nuclear safety work in various countries. It is concluded that essential objectives for reactor safety work must be: (1) to prevent accidents from developing into severe core damage, even if they are initiated by very unlikely natural or man-made events, and, recognizing that accidents with severe core damage may nevertheless occur; (2) to prevent large-scale and long lived ground contamination by limiting releases of radioactive nuclides such as cesium to less than about 100 TBq. To achieve these objectives the importance of maintaining high global standards of safety management and safety culture cannot be emphasized enough. All three severe accidents discussed in this paper had their root causes in system deficiencies indicative of poor safety management and poor safety culture in both the nuclear industry and government authorities.

  1. Impact of coal combustion from thermal power plant: estimates on ambient SO2 levels

    International Nuclear Information System (INIS)

    Joshi, P.V.

    1991-01-01

    Using a Gaussian dispersion model, ambient Ground Levels Concentrations (GLC) of SO 2 due to Nashik Thermal Power Plant have been computed. Annual GLC in 16 cardinal sectors and concentration levels in 6 atmospheric stability classes have been estimated as a function of down wind distance. The values are compared with national ambient air quality standard and risk involved due to the release of SO 2 from power plant has been assessed. (author). 8 refs., 2 appendixes

  2. Development of a unified transport approach for the assessment of power-plant impact

    International Nuclear Information System (INIS)

    Akin, E.J.; Barton, J.M.; Bledsoe, J.L.

    1977-01-01

    Progress during the first 18 months in implementation of the Unified Transport Approach (UTA) is summarized in this report, which covers the period through December 1976. The goal of this project is to develop mathematical models for fast-transient, one-and two-dimensional transport of thermal, radiological, chemical, and biological properties in rivers, estuaries, lakes, and coastal regions for assessing the impact of power-plant operations. Development and validation of these models are illustrated in applications at several sites where data is available. The models include submodels for sediment transport, exchange of a soluble isotope with sediment, and zone-matching models to connect near-field problems of reentrainment and recirculation with far-field convective transport. Several types of automated data preparation have been introduced, and the codes have been designed to allow input of specified plant operating conditions for given durations. The UTA provides a common basis for calculating the transport of intensive quantities that depend on basic flow properties, which can be obtained from a common set of data for geometry, bathymetry, and meteorology that must be prepared only once. The formulation and calculation are based on a stable set of algorithms that have been tested and proven valid. The user can then focus on understanding and interpreting thermal, chemical, or radiological transport results with confidence that the basic calculations are direct, efficient, and meaningful. Recent work in each of the three areas is described

  3. Summary of the financial and ratepayer impacts of nuclear power plant regulatory reform

    International Nuclear Information System (INIS)

    Turpin, A.Y.

    1985-05-01

    This report estimates the financial impact on utilities and ratepayers of nuclear power plant regulatory reforms. Three situations are investigated: (1) no reform, (2) combined early-site-permit and preapproval-of-design reforms, and (3) total reform. Also, two types of capacity additions are evaluated using two utility companies as case studies: (1) nuclear plus generic capacity, and (2) all-nuclear capacity. Results indicate that both the shorter construction lead-time afforded by nuclear regulatory reform and the timing of new capacity additions are extremely important in enabling a utility to remain in a healthy financial position while adding capacity to meet future demand and at the same time reducing the price of electricity to the ratepayers. The lower added capital costs and fuel cost savings obtained from reformed nuclear units allow a utility dependent on oil and gas steam generation to experience price decreases as these new units begin commercial operation. The study also points out that in simulations excluding the shorter lead-time generic capacity, price increases were greater and financial performance was worse for both utilities. These facts indicate the importance of shortening the construction lead-time through nuclear regulatory reform so that nuclear power will be more competitive with coal. 19 refs., 4 figs., 3 tabs

  4. Environment Quality: Impact From Traffic, Power Plant and Land Morphology, a Case Study of Prishtina

    Science.gov (United States)

    Bajcinovci, Bujar

    2017-05-01

    Environmental air pollution is a global health concern, a complex phenomenon which is directly reflected on public health, economic and human development. Environmental air pollution has been drastically multiplied, followed by the beginning of the new Millennia in Prishtina, the capital city of the Kosovo. The new millennium began as a crucial activity for the city of Prishtina in terms of demographic, human geography, social and economic phenomena. The presented study aims to determine prevalent traffic and land morphology composition attributes, which have influenced and continue to have environmental impact in the city of Prishtina. According to the conceptual findings from the empirical observations, the heavy city traffic and the land morphology structure, determine the urban air pollution level. Prishtina is generally polluted due to its geomorphic position in relation to the power plants Kosovo A, and Kosova B. The impact of the above cited factors, is even bigger when the dominant winds prevail through valley, which encompasses the city. The findings from this paper propose the necessity of careful driven urban solutions.

  5. Environment Quality: Impact From Traffic, Power Plant and Land Morphology, a Case Study of Prishtina

    Directory of Open Access Journals (Sweden)

    Bajcinovci Bujar

    2017-05-01

    Full Text Available Environmental air pollution is a global health concern, a complex phenomenon which is directly reflected on public health, economic and human development. Environmental air pollution has been drastically multiplied, followed by the beginning of the new Millennia in Prishtina, the capital city of the Kosovo. The new millennium began as a crucial activity for the city of Prishtina in terms of demographic, human geography, social and economic phenomena. The presented study aims to determine prevalent traffic and land morphology composition attributes, which have influenced and continue to have environmental impact in the city of Prishtina. According to the conceptual findings from the empirical observations, the heavy city traffic and the land morphology structure, determine the urban air pollution level. Prishtina is generally polluted due to its geomorphic position in relation to the power plants Kosovo A, and Kosova B. The impact of the above cited factors, is even bigger when the dominant winds prevail through valley, which encompasses the city. The findings from this paper propose the necessity of careful driven urban solutions.

  6. Impact of New Radiation Safety Standards on Licensing Requirements of Nuclear Power Plant

    International Nuclear Information System (INIS)

    Strohal, P.; Subasic, D.; Valcic, I.

    1996-01-01

    As the outcomes of the newly introduced safety philosophies, new and more strict safety design requirements for nuclear installation are expected to be introduced. New in-depth defence measures should be incorporated into the design and operation procedure for a nuclear installation, to compensate for potential failures in protection or safety measures. The new requirements will also apply to licensing of NPP's operation as well as to licensing of nuclear sites, especially for radioactive waste disposal sites. This paper intends to give an overview of possible impacts of new internationally agreed basic safety standards with respect to NPP and related technologies. Recently issued new basic safety standards for radiation protection are introducing some new safety principles which may have essential impact on future licensing requirements regarding nuclear power plants and radioactive waste installations. These new standards recognize exposures under normal conditions ('practices') and intervention conditions. The term interventions describes the human activities that seek to reduce the existing radiation exposure or existing likelihood of incurring exposure which is not part of a controlled practice. The other new development in safety standards is the introduction of so called potential exposure based on the experience gained from a number of radiation accidents. This exposure is not expected to be delivered with certainty but it may result from an accident at a source or owing to an event or sequence of events of a probabilistic nature, including equipment failures and operating errors. (author)

  7. Hydroelectric Power Plants Dobsina

    International Nuclear Information System (INIS)

    Majercak, V.; Srenkelova, Z.; Kristak, J.G.

    1997-01-01

    In this brochure the Hydroelectric Power Plants Dobsina, (VED), subsidiary of the utility Slovenske Elektrarne, a.s. (Slovak Electric, plc. Bratislava) are presented. VED is mainly aimed at generating peak-load electrical energy and maintenance of operational equipment. Reaching its goals, company is first of all focused on reliability of production, economy and effectiveness, keeping principles of work safety and industry safety standards and also ecology. VED operates eight hydroelectric power plants, from which PVE Ruzin I and PVE Dobsina I are pump storage ones and they are controlled directly by the Slovak Energy Dispatch Centre located in Zilina thought the system LS 3200. Those power plants participate in secondary regulation of electrical network of Slovakia. They are used to compensate balance in reference to foreign electrical networks and they are put into operation independently from VED. Activity of the branch is focused mainly on support of fulfilment of such an important aim as electric network regulation. Beginnings of the subsidiary Hydroelectric Power Plants Dobsina are related to the year of 1948. After commissioning of the pump storage Hydroelectric Power Plants Dobsina in 1953, the plant started to carry out its mission. Since that time the subsidiary has been enlarged by other seven power plants, through which it is fulfilling its missions nowadays. The characteristics of these hydroelectric power plants (The pump-storage power plant Dobsina, Small hydroelectric power plant Dobsina II, Small hydroelectric power plant Rakovec, Small hydroelectric power plant Svedlar, Hydroelectric power plant Domasa, The pump-storage power plant Ruzin, and Small hydroelectric power plant Krompachy) are described in detail. Employees welfare and public relations are presented

  8. Construction of Temelin nuclear power plant and its impact on possible recreational uses of the area

    Energy Technology Data Exchange (ETDEWEB)

    Uvirova, E

    1985-01-01

    The possible recreational use is assessed of the territory within 25 kms from the Temelin nuclear power plant site. The territory includes 3 tourist areas (South Bohemian lakes, Middle Vltava, Tabor area). From the point of view of time usability, all three areas are of the single-season type, i.e., they are used in the summer season, as they are oriented to water sports and tourism. Neither the Temelin nuclear power plant nor its 3 km protective zone overlap with the reacreational areas, and thus the areas can also in future be used for tourism. The use of the Temelin plant in district heating will contribute to reducing fallout from the existing thermal power plants. (J.C.).

  9. Construction of Temelin nuclear power plant and its impact on possible recreational uses of the area

    International Nuclear Information System (INIS)

    Uvirova, E.

    1985-01-01

    The possible recreational use is assessed of the territory within 25 kms from the Temelin nuclear power plant site. The territory includes 3 tourist areas (South Bohemian lakes, Middle Vltava, Tabor area). From the point of view of time usability, all three areas are of the single-season type, i.e., they are used in the summer season, as they are oriented to water sports and tourism. Neither the Temelin nuclear power plant nor its 3 km protective zone overlap with the reacreational areas, and thus the areas can also in future be used for tourism. The use of the Temelin plant in district heating will contribute to reducing fallout from the existing thermal power plants. (J.C.)

  10. Impact of digital information and control system platform selection on nuclear power generating plant operating costs

    International Nuclear Information System (INIS)

    Bogard, T.; Radomski, S.; Sterdis, B.; Marta, H.; Bond, V.; Richardson, J.; Ramon, G.; Edvinsson, H.

    1998-01-01

    Information is presented on the benefits of a well-planned information and control systems (I and CS) replacement approach for aging nuclear power generating plants' I and CS. Replacement of an aging I and CS is accompanied by increases in plant profitability. Implementing a structured I and CS replacement with current technology allows improved plant electrical production in parallel with reduced I and CS operations and maintenance cost. Qualitative, quantitative, and enterprise management methods for cost benefit justification are shown to justify a comprehensive approach to I and CS replacement. In addition to the advantages of standard I and CS technologies, examples of new I and CS technologies are shown to add substantial cost benefit justification for I and CS replacements. Focus is upon I and CS replacements at nuclear power plants, however the information is applicable to other types of power generating facilities. (author)

  11. Survey of radionuclide emissions from coal-fired power plants and examination of impacts from a proposed circulating fluidized bed boiler power plant

    International Nuclear Information System (INIS)

    Steiner, C.P.; Militana, L.M.; Harvey, K.A.; Kinsey, G.D.

    1995-01-01

    This paper presents the results of a literature survey that examined radionuclide emissions from coal-fired power plants. Literature references from both the US and foreign countries are presented. Emphasis is placed on references from the US because the radionuclide emissions from coal-fired power plants are related to radionuclide concentrations in the coal, which vary widely throughout the world. The radionuclides were identified and quantified for various existing power plants reported in the literature. Applicable radionuclide emissions criteria discovered in the literature search were then applied to a proposed circulating fluidized bed boiler power plant. Based upon the derived radionuclide emission rates applied to the proposed power plant, an air quality modeling analysis was performed. The estimated ambient concentrations were compared to the most relevant existing regulatory ambient levels for radionuclides

  12. Local Impacts of Mercury Emissions from the Three Pennsylvania Coal Fired Power Plants.

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan,T.; Adams,J.; Bender, M.; Bu, C.; Piccolo, N.; Campbell, C.

    2008-02-01

    The Clean Air Interstate Rule (CAIR) and the Clean Air Mercury Rule (CAMR) as proposed by the U.S. Environmental Protection Agency (EPA) when fully implemented will lead to reduction in mercury emissions from coal-fired power plants by 70 percent to fifteen tons per year by 2018. The EPA estimates that mercury deposition would be reduced 8 percent on average in the Eastern United States. The CAMR permits cap-and-trade approach that requires the nationwide emissions to meet the prescribed level, but do not require controls on each individual power plant. This has led to concerns that there may be hot-spots of mercury contamination near power plants. Partially because of this concern, many states including Pennsylvania have implemented, or are considering, state regulations that are stricter on mercury emissions than those in the CAMR. This study examined the possibility that coal-fired power plants act as local sources leading to mercury 'hot spots'. Soil and oak leaf samples from around three large U.S. coal-fired power plants in Western Pennsylvania were collected and analyzed for evidence of 'hot spots'. These three plants (Conemaugh, Homer City, and Keystone) are separated by a total distance of approximately 30 miles. Each emits over 500 pounds of mercury per year which is well above average for mercury emissions from coal plants in the U.S. Soil and oak leaf sampling programs were performed around each power plant. Sampling rings one-mile apart were used with eight or nine locations on each ring. The prevailing winds in the region are from the west. For this reason, sampling was conducted out to 10 miles from the Conemaugh plant which is southeast of the others. The other plants were sampled to a distance of five miles. The objectives were to determine if local mercury hot spots exist, to determine if they could be attributed to deposition of coal-fired power plant emissions, and to determine if they correlated with wind patterns. The study

  13. An analysis of the impacts of economic incentive programs on commercial nuclear power plant operations and maintenance costs

    International Nuclear Information System (INIS)

    Kavanaugh, D.C.; Monroe, W.H.; Wood, R.S.

    1996-02-01

    Operations and Maintenance (O and M) expenditures by nuclear power plant owner/operators possess a very logical and vital link in considerations relating to plant safety and reliability. Since the determinants of O and M outlays are considerable and varied, the potential linkages to plant safety, both directly and indirectly, can likewise be substantial. One significant issue before the US Nuclear Regulatory Commission is the impact, if any, on O and M spending from state programs that attempt to improve plant operating performance, and how and to what extent these programs may affect plant safety and pose public health risks. The purpose of this study is to examine the role and degree of impacts from state promulgated economic incentive programs (EIPs) on plant O and M spending. A multivariate regression framework is specified, and the model is estimated on industry data over a five-year period, 1986--1990. Explanatory variables for the O and M spending model include plant characteristics, regulatory effects, financial strength factors, replacement power costs, and the performance incentive programs. EIPs are found to have statistically significant effects on plant O and M outlays, albeit small in relation to other factors. Moreover, the results indicate that the relatively financially weaker firms are more sensitive in their O and M spending to the presence of such programs. Formulations for linking spending behavior and EIPs with plant safety performance remains for future analysis

  14. Exergic, economic and environmental impacts of natural gas and diesel in operation of combined cycle power plants

    International Nuclear Information System (INIS)

    Mohammadi Khoshkar Vandani, Amin; Joda, Fatemeh; Bozorgmehry Boozarjomehry, Ramin

    2016-01-01

    Highlights: • Investigating the effect of natural gas and diesel on the power plant performance. • Exergy, economic and environmental evaluation of a combined cycle power plant. • Using life cycle assessment (LCA) to perform the environmental evaluation. • Optimizing the power plant in terms of exergy and economic. • Better performance of natural gas with respect to diesel. - Abstract: Combined cycle power plants (CCPPs) play an important role in electricity production throughout the world. Their energy efficiency is relatively high and their production rates of greenhouse gases are considerably low. In a country like Iran with huge oil and gas resources, most CCPP’s use natural gas as primary fuel and diesel as secondary fuel. In this study, effect of using diesel instead of natural gas for a selected power plant will be investigated in terms of exergy, economic and environmental impacts. The environmental evaluation is performed using life cycle assessment (LCA). In the second step, the operation of the plant will be optimized using exergy and economic objective functions. The results show that the exergy efficiency of the plant with natural gas as fuel is equal to 43.11%, while this efficiency with diesel will be 42.03%. Furthermore, the annual cost of plant using diesel is twice as that of plant using natural gas. Finally, diesel utilization leads to more contaminants production. Thus, environmental effects of diesel are much higher than that of natural gas. The optimization results demonstrate that in case of natural gas, exergy efficiency and annual cost of the power plant improve 2.34% and 4.99%, respectively. While these improvements for diesel are 2.36% and 1.97%.

  15. Air quality impact of two power plants using a sub-grid

    International Nuclear Information System (INIS)

    Drevet, Jerome; Musson-Genon, Luc

    2012-01-01

    Modeling point source emissions of air pollutants with regional Eulerian models is likely to lead to errors because a 3D Eulerian model is not able to correctly reproduce the evolution of a plume near its source. To overcome these difficulties, we applied a Gaussian puff model - imbedded within a 3D Eulerian model - for an impact assessment of EDF fossil fuel-fired power plants of Porcheville and Vitry, Ile-de-France. We simulated an entire year of atmospheric processes for an area covering the Paris region with the Polyphemus platform with which we conducted various scenarios with or without a Gaussian puff model, referred as Plume-in-grid, to independently handle 'with major point source emissions in Ile-de-France. Our study focuses on four chemical compounds (NO, NO 2 , SO 2 and O 3 ). The use of a Gaussian model is important, particularly for primary compounds with low reactivity such as SO, especially as industrial stacks are the major source of its emissions. SO 2 concentrations simulated using Plume-in-grid tare closer to the concentrations measured by the stations of the air quality agencies (Associations Agreees de Surveillance de la Qualite de l'Air, AASQA), although they remain largely overestimated. The use of a Gaussian model increases the concentrations near the source and lowers background levels of various chemical species (except O 3 ). The simulated concentrations may vary by over 30 % depending on whether we consider the Gaussian model for primary compounds such as SO 2 and NO, and around 2 % for secondary compounds such as NO 2 and O 3 . Regarding the impact of fossil fuel-fired power plants, simulated concentrations are increased by about 1 μg/m 3 approximately for SO 2 annual averages close to the Porcheville stack and are lowered by about 0.5 μg/m 3 far from the sources, highlighting the less diffusive character of the Gaussian model by comparison with the Eulerian model. The integration of a sub-grid Gaussian model offers the advantage of

  16. Evaluation of ecosystem simulation models as tools for assessment of power plant impacts on fish populations. Final report

    International Nuclear Information System (INIS)

    Swartzman, G.L.

    1984-07-01

    This report summarizes work on evaluating the usefulness of models in assessing power plant impacts. Models were found to be most useful in suggesting frequency and replication for monitoring programs. Models also were useful in indicating where further data are needed. The modeling work on Lake Ontario and Lake Keowee indicated difficulties in using monitoring data for model construction and validation

  17. Impacts from a fossil fuel power plant on ozone levels in Memphis, Tennessee

    International Nuclear Information System (INIS)

    Mueller, S.F.; Bailey, E.M.

    1998-01-01

    The Tennessee Valley Authority (TVA) Allen power plant is located on the Mississippi River in the southwest corner of Memphis, Tennessee. Allen has three coal-fired cyclone boilers with a rated capacity of 272 MW each. It is a Phase 2 plant under Title IV of the Clean Air Act and is the largest single source of NO x in the Memphis area. TVA plans to reduce Allen NOx emissions through a combination of burning low-sulfur coal (which has the benefit of reducing NO x emissions while also reducing SO 2 emissions) and installing gas re-burn technology. A modeling study using the SAI, Inc., UAM-V photochemical model was conducted to examine the potential impacts of NO x reductions on ozone levels in the Memphis area. A series of four model simulations were made in which different Allen emissions scenarios were examined. The focus period of the photochemical modeling was 11--14 July 1995 when measurements in and near Memphis indicated peak hourly ozone levels of 135--140 ppb. This analysis primarily examined computed impacts within 50 km of Memphis. Allen was computed to contribute as much as 20--30 ppb to ground ozone levels 20-50 km downwind using its NO x emission rate before Title IV compliance. After compliance it was computed to contribute only about 10--20 ppb. At the same time, maximum daily ozone reductions due to Allen NO x titration of ozone were between 30 and 60 ppb. These benefits will be reduced by 30--50% after Title IV compliance, and are expected to occur within 30 km of the plant. More model grid cells indicated dis-benefits (net ground-level ozone increases) than benefits on three of the four episode days using the Title IV compliance emission rate. Significant ozone dis-benefits were expected because of the well-documented NO titration of ozone within plumes having a high ratio of NO to volatile organic compounds

  18. Small hydroelectric power plants

    International Nuclear Information System (INIS)

    Helgesen, Boerre

    2002-01-01

    Small hydroelectric power plants are power plants of 1 - 10 MW. For a supplier, this is an unnatural limit. A more natural limit involves compact engine design and simplified control system. The article discusses most of the engine and electrotechnical aspects in the development, construction and operation of such a plant

  19. Development of the simulation system {open_quotes}IMPACT{close_quotes} for analysis of nuclear power plant severe accidents

    Energy Technology Data Exchange (ETDEWEB)

    Naitoh, Masanori; Ujita, Hiroshi; Nagumo, Hiroichi [Nuclear Power Corp. (Japan)] [and others

    1997-07-01

    The Nuclear Power Engineering Corporation (NUPEC) has initiated a long-term program to develop the simulation system {open_quotes}IMPACT{close_quotes} for analysis of hypothetical severe accidents in nuclear power plants. IMPACT employs advanced methods of physical modeling and numerical computation, and can simulate a wide spectrum of senarios ranging from normal operation to hypothetical, beyond-design-basis-accident events. Designed as a large-scale system of interconnected, hierarchical modules, IMPACT`s distinguishing features include mechanistic models based on first principles and high speed simulation on parallel processing computers. The present plan is a ten-year program starting from 1993, consisting of the initial one-year of preparatory work followed by three technical phases: Phase-1 for development of a prototype system; Phase-2 for completion of the simulation system, incorporating new achievements from basic studies; and Phase-3 for refinement through extensive verification and validation against test results and available real plant data.

  20. Environmental impact of fossil fuel utilization in the thermal power plant

    International Nuclear Information System (INIS)

    Ghasem D Najafpour; Seyed Jafar Mehdizadeh; Abdul Rahman Mohamed

    2000-01-01

    Carbon dioxide causes green house effect, has been considered as a pollutant source of our safe environment. Since combustion of fossil fuel may create tremendous amount of carbon dioxide, detecting any pollutant sources would be important to eliminate the pollution sources. Evaluation of smoke dispersion that has been generated by a power plant utilizing fossil fuel is the objective of this paper. The concentration of NO, and SO, in the soil, have been analyzed from a distance of 3 to 4 km far from power plant. The experimental results shown. that the concentration of toxic gases was a little above the international standards. Replacement of fossil fuel by natural gas caused NO, concentration to be developed in the atmosphere, therefore usage of natural gas is limited by environmental protection agencies. Beside the nuclear power plant, the power generated by other sources. are limited. Electric power generated by water dam is not a major contribution of electric power demand. Therefore generation of electricity by any other energy sources, which are friendly to the environment, is recommended. Other sources of energy, such as wind power, solar energy, geothermal, ocean thennal and renewable source of energy can be considered safe for the environment. The goal of environmental management system would be to meet the minimum requirements were established and demanded by the local environmental protection agency or international standard organization (ISO-14000). (Author)

  1. Effects of Moat Wall Impact on the Seismic Response of Base Isolated Nuclear Power Plants

    International Nuclear Information System (INIS)

    Kim, Min Kyu; Kim, Jung Han; Mosqueda, Gilberto; Sarebanhab, Alireza

    2015-01-01

    The objectives of this study are to examine the effects of impact on the response of seismically isolated NPPs and identify characteristics of the isolation hardware and hard stop that minimize these effects. Considering variable distances to the hard stop and properties of the moat wall, the amplification in response is reported for acceleration and floor spectral accelerations at different points along the height of a NPP containment structure. Base isolation can be an effective strategy to protect critical facilities such as Nuclear Power Plants (NPPs) from the damaging effects of horizontal earthquake ground shaking. To be effective in reducing accelerations and deformations of the structure above, the seismic isolation bearings can be subjected to large displacements. In the case of an extreme earthquake, bearing displacements need to be limited by a hard stop in order to prevent failure of the bearings. Impact to the hard stop, which is often the moat wall at the basement level, is also of significant concern due to the potential for increased transfer of forces and amplification in response of the structural system, piping and other contents. However, the consequences of impact or factors important to mitigate its effects are not very well understood. The main findings of this study are related to modeling of NPP with moat wall in OpenSees and LSDyna as well as observations resulting from the parametric study of the performance of the NPP under different intensity levels of seismic excitations for different properties of the moat wall and bearings. • Variation in the isolator properties should be considered when examining seismic pounding. For BDBE even, 58.5 % cases result to the impact for lower bound properties while this value was 5.5 % for upper bound properties. Since the impact results are dependent to the assumed bearing properties, a better range of properties can be obtained from experimental testing of the bearing under large shear strains.

  2. Optimized reinforcement of nuclear power plant structures for aircraft impact forces

    International Nuclear Information System (INIS)

    Zerna, W.; Schnellenbach, G.; Stangenberg, F.

    1976-01-01

    Reactor buildings of nuclear power plants and, to some extent also other buildings of the plant, according to the present safety requirements, have to be able to withstand aircraft impact forces. The building has to withstand this loading only once since afterwards it will be out of use. Accordingly, other criteria for design and the necessary safety measures are valid than in the case of service loads. Large deformations and the development of large cracks due to such loadings are insignificant from a construction point of view for reinforced concrete structures i.e. the stresses can build up to the ultimate load carrying capacity. From the nuclear safety point of view, however, some restrictions are possible in this regard e.g. to obstruct the penetration of fuel through the cracks. Basically all mild steels, with large ducility and without brittle fracture under sudden load increase, are suitable for this purpose. High stresses in the structure would, however, require uneconomical concentrations of mild steel. It is for this reason that the use of high strength steels e.g. St 110/135, has been introduced in Germany for this kind of loading. Through the use of wire strands or cables of high strength steel it is possible to reach a condition of cracks and large deformations due to ultimate loads in zone of point loading. The reinforcement takes on a distinctly curved shape and is able to carry the normal loads and shears through a suspension-structure action. The deformability of the structure for the analysed limit load state can be further increased through a bond-free net. This measure allows a more uniform sketching of the cables or strands over a larger zone. (Auth.)

  3. Distance matters. Assessing socioeconomic impacts of the Dukovany nuclear power plant in the Czech Republic: Local perceptions and statistical evidence

    Czech Academy of Sciences Publication Activity Database

    Frantál, Bohumil; Malý, Jiří; Ouředníček, M.; Nemeškal, J.

    2016-01-01

    Roč. 24, č. 1 (2016), s. 2-13 ISSN 1210-8812 R&D Projects: GA MŠk(CZ) EE2.3.20.0025 Institutional support: RVO:68145535 Keywords : nuclear power plant impacts * spatial analysis * risk perceptions Subject RIV: DE - Earth Magnetism, Geodesy, Geography Impact factor: 2.149, year: 2016 http://www.degruyter.com/view/j/mgr.2016.24.issue-1/mgr-2016-0001/mgr-2016-0001.xml?format=INT

  4. Radiological impact of airborne effluents of coal-fired and nuclear power plants

    International Nuclear Information System (INIS)

    McBride, J.P.; Moore, R.E.; Witherspoon, J.P.; Blanco, R.E.

    1977-06-01

    Radiological impact of naturally occurring radionuclides in airborne effluents of a model coal-fired steam plant is evaluated assuming a release to the atmosphere of 1 percent of the ash in the coal burned and compared with the impact of radioactive materials in the airborne effluents of model light-water reactors. The principal exposure pathway for radioactive materials released from both types of plants is ingestion of contaminated foodstuffs. For nuclear plants immersion in the airborne effluents is also a significant factor in the dose commitment. Assuming that the coal burned contains 1 ppM uranium and 2 ppM thorium together with their decay products and using the same impact analysis methods used in evaluating nuclear facilities, the maximum individual dose commitments from the coal plant for the whole body and most organs (except the thyroid) are shown to be greater than those from a pressurized-water reactor (PWR) and, with the exception of the bone and kidney doses, less than those from a boiling-water reactor (BWR). With the exception of the bone dose, the maximum individual dose commitments from the coal plant are less than the numerical design guideline limits listed for light-water reactors (LWRs). Population dose commitments from the coal plant are higher than those from either nuclear plant

  5. Impact of power plant discharge on the physico-chemical characteristics of Kalpakkam coastal waters

    International Nuclear Information System (INIS)

    Satpathy, K.K.; Nair, K.V.K.

    1990-01-01

    Measurements of air and sea surface temperature, dissolved oxygen, salinity, Secchidisc depth and seston content of the coastal water at Kalpakkam have been carried out since 1982. The paper discusses the seasonal variations in the above parameters and the impact of power plant operation on these. The annual sea surface temperature during the post-operational period of the reactor largely followed a trend similar to that of the pre-operational period. However, there was a marginal reduction in the difference between annual maxima and minima and a general flattening of the moving average during the post-operational period as compared to the pre-operational period. During the period of study lowest salinity values of 21.94x10 -3 (NE monsoon, November 1985) and 27.81x10 -3 (SW monsoon, July 1985) were observed. A marginal reduction in water transparency and an increase in the seston content (highest 53.1 mg/l) were the other major changes observed during the post-operational period. (author). 7 refs., 2 tabs., 6 figs

  6. Safe Operation of Nuclear Power Plants: Impacts of Human and Organisational Factors and Emerging Technologies

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    In co-operation with the OECD Nuclear Energy Agency (NEA), the Halden Reactor Project organised a Summer School on ''Safe Operation of Nuclear Power Plants: Impacts of Human and Organisational Factors and Emerging Technologies'' in the period August 27-August 31, 2001. The Summer School was intended for scientists, engineers and technicians working for nuclear installations, engineering companies, industry and members of universities and research institutes, who wanted to broaden their nuclear background by getting acquainted with Man-Technology-Organisation-related subjects and issues. The Summer School should also serve to transfer knowledge to the ''young generation'' in the nuclear field. The following presentations were given: (1) Overview of the Nuclear Community and Current issues, (2) The Elements of Safety Culture; Evaluation of Events, (3) Quality Management (QM), (4) Probabilistic Risk Assessment (PSA), (5) Human Behaviour from the Viewpoint of Industrial Psychology, (6) Technical tour of the Halden Project Experimental Facilities, (7) Human Factors in Control Room Design, (8) Computerised Operator Support Systems (COSSs) and (9) Artificial Intelligence; a new Approach. Most of the contributions are overhead figures from spoken lectures.

  7. Safe Operation of Nuclear Power Plants: Impacts of Human and Organisational Factors and Emerging Technologies

    International Nuclear Information System (INIS)

    2001-01-01

    In co-operation with the OECD Nuclear Energy Agency (NEA), the Halden Reactor Project organised a Summer School on ''Safe Operation of Nuclear Power Plants: Impacts of Human and Organisational Factors and Emerging Technologies'' in the period August 27-August 31, 2001. The Summer School was intended for scientists, engineers and technicians working for nuclear installations, engineering companies, industry and members of universities and research institutes, who wanted to broaden their nuclear background by getting acquainted with Man-Technology-Organisation-related subjects and issues. The Summer School should also serve to transfer knowledge to the ''young generation'' in the nuclear field. The following presentations were given: (1) Overview of the Nuclear Community and Current issues, (2) The Elements of Safety Culture; Evaluation of Events, (3) Quality Management (QM), (4) Probabilistic Risk Assessment (PSA), (5) Human Behaviour from the Viewpoint of Industrial Psychology, (6) Technical tour of the Halden Project Experimental Facilities, (7) Human Factors in Control Room Design, (8) Computerised Operator Support Systems (COSSs) and (9) Artificial Intelligence; a new Approach. Most of the contributions are overhead figures from spoken lectures

  8. Environmental impact of geothermal power plants in Aydın, Turkey

    Science.gov (United States)

    Yilmaz, Ersel; Ali Kaptan, Mustafa

    2017-10-01

    Geothermal energy is classified as a clean and sustainable energy source, like all industrial activities, geothermal energy power plants (GEPP) technology has also some positive and negative effects on the environment. In this paper are presented by attent not only on environmental impacts of GEPP onto Büyük Menderes River and fresh water sources, which ere used for irrigation of agricultural fields from tousands of years in basin, but also on water quality contents like heavy metals and gases emition due to drilling and electricity producing technology of GEPP's. Aydın province is located in the southwestern part of the region and its city center has around 300000 population. The high geothermal potential of this region became from geographical location, which is held on active tectonic Alpine-Himalaya Orogen belt with active volcanoes and young faults. Since 1980's to 2016 there is about 70.97% (662.75 MW) of installed capacity by according to the Mineral Research and Exploration General Directorate, there are totally 290 well licensed (540 explore licenses and 76 business licenses), and 31 geothermal powerplants purposely installed. Topic is important because of number of GEPP increased rapidly after 2012 to now a days to 36 in whole basin.

  9. Safe Operation of Nuclear Power Plants: Impacts of Human and Organisational Factors and Emerging Technologies

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    In co-operation with the OECD Nuclear Energy Agency (NEA), the Halden Reactor Project organised a Summer School on ''Safe Operation of Nuclear Power Plants: Impacts of Human and Organisational Factors and Emerging Technologies'' in the period August 27-August 31, 2001. The Summer School was intended for scientists, engineers and technicians working for nuclear installations, engineering companies, industry and members of universities and research institutes, who wanted to broaden their nuclear background by getting acquainted with Man-Technology-Organisation-related subjects and issues. The Summer School should also serve to transfer knowledge to the ''young generation'' in the nuclear field. The following presentations were given: (1) Overview of the Nuclear Community and Current issues, (2) The Elements of Safety Culture; Evaluation of Events, (3) Quality Management (QM), (4) Probabilistic Risk Assessment (PSA), (5) Human Behaviour from the Viewpoint of Industrial Psychology, (6) Technical tour of the Halden Project Experimental Facilities, (7) Human Factors in Control Room Design, (8) Computerised Operator Support Systems (COSSs) and (9) Artificial Intelligence; a new Approach. Most of the contributions are overhead figures from spoken lectures.

  10. Social and economic impacts of the Trojan Nuclear Power Plant: a confirmatory technology assessment. Technical report

    International Nuclear Information System (INIS)

    Wenk, E. Jr.; Bereano, P.L.; Douglass, J.; Watson, R.H.; Zemansky, G.M.

    1979-10-01

    The Trojan nuclear plant located 32 miles northwest of Portland, Oregon was chosen for a case study. A background of the physical, demographic, economic, and political context of the communities is provided. This is followed by an evaluation of the impacts of plant construction and operation including local taxation, employment, business activity and income, demography, public utilities and transportation, land use, housing, recreation, culture and lifestyle, public safety, education, health care, and politics and institutions

  11. Less power plants

    International Nuclear Information System (INIS)

    TASR

    2003-01-01

    In the Slovak Republic the number of company power plants decreased as against 2001 by two sources. In present time only 35 companies have their own power plants. The companies Slovnaft, Kappa Sturovo, Slovensky hodvab Senica, Matador Puchov, Maytex Liptovsky MikuIas, Kovohuty Krompachy, Chemko Strazske and some Slovak sugar factories belong to the largest company power plants in force of distributing companies. Installed output of present 35 company sources is 531 MW. The largest of separate power plants as Paroplynovy cyklus Bratislava (218 MW) and VD Zilina (72 MW) belong to independent sources. Total installed output of Slovak sources was 8306 MW in the end of last year

  12. Evaluation of nuclear power plant siting by probabilistic assessment of environmental impacts

    International Nuclear Information System (INIS)

    Vuori, S.

    1978-01-01

    The work consists of the description of a probabilistic consequence assessment model ARANO, and the individual calculation schemes therein included. This assessment model has been applied to the risk/benefit and cost/benefit analyses of the siting of nuclear power plants. In addition, there have been made some comparisons with the alternative fossil fuelled energy production scenarios. (author)

  13. Impact of Advanced Alarm Systems and Information Displays on Human Reliability in the Digital Control Room of Nuclear Power Plants

    International Nuclear Information System (INIS)

    Kim, Jong Hyun; Dang, Vinh N

    2011-01-01

    This paper discusses the potential impacts of two advanced features of digital control rooms, alarm systems and information display systems, on the Human Reliability Analysis (HRA) in nuclear power plants. Although the features of digital control rooms have already been implemented in new or upgraded nuclear power plants, HRAs have so far not taken much credit for these features. In this circumstance, this paper aims at examining the potential effects of these features on human performance and discussing how these effects can be addressed with existing HRA methods. A conclusion derivable from past experimental studies is that those features are supportive in the severe conditions such as complex scenarios and knowledge-based works. However, in the less complex scenarios and rule-based work, they may have no difference with or sometimes negative impacts on operator performance. The discussion about the impact on the HRA is provided on the basis on the THERP method

  14. Sensitivity analysis of the evaluation of power plants impact on the living standard using the analytic hierarchy process

    International Nuclear Information System (INIS)

    Chatzimouratidis, Athanasios I.; Pilavachi, Petros A.

    2008-01-01

    Ten types of power plant were evaluated as to their impact on the living standard. Power plant evaluation incorporates a number of criteria that can be assessed either objectively or subjectively. Objective assessments are usually quantitative and are based on real data, while subjective assessments are rather qualitative and derive from decision makers' intuition, culture and experience. Because of diversity of decision makers' opinions, subjective assessments are due to vary. Several scenarios should therefore be examined in order to evaluate what happens under different assessments. Even objective assessments can vary because of data changes due to technology and socioeconomic evolution. This is why the application of a sensitivity analysis is required in order to examine result changes under different input data. This analysis should cover all criteria and subcriteria as well as their possible combinations in the different levels of the hierarchy tree. The results show that the five types of renewable energy based power plant rank in the first five positions regardless of criteria weight variations, due to their balanced high scores against them. Only biomass drops to the eighth position when quality of life has 100% weight. Nuclear power plants show impressive score and ranking variations between the first position for 100% quality of life weight and the tenth for 100% socioeconomic aspects weight. Natural gas based power plants rank slightly higher when quality of life importance increases while coal/lignite and oil have slightly better rankings when priority is given to socioeconomic aspects

  15. Impact of inlet fogging and fuels on power and efficiency of gas turbine plants

    Directory of Open Access Journals (Sweden)

    Basha Mehaboob

    2013-01-01

    Full Text Available A computational study to assess the performance of different gas turbine power plant configurations is presented in this paper. The work includes the effect of humidity, ambient inlet air temperature and types of fuels on gas turbine plant configurations with and without fogger unit. Investigation also covers economic analysis and effect of fuels on emissions. GT frames of various sizes/ratings are being used in gas turbine power plants in Saudi Arabia. 20 MWe GE 5271RA, 40 MWe GE-6561B and 70 MWe GE-6101FA frames are selected for the present study. Fogger units with maximum mass flow rate of 2 kg/s are considered for the present analysis. Reverse Osmosis unit of capacity 4 kg/s supplies required water to the fogger units. GT PRO software has been used for carrying out the analysis including; net plant output and net efficiency, break even electricity price and break even fuel LHV price etc., for a given location of Saudi Arabia. The relative humidity and temperature have been varied from 30 to 45 % and from 80 to 100° F, respectively. Fuels considered in the study are natural gas, diesel and heavy bunker oil. Simulated gas turbine plant output from GT PRO has been validated against an existing gas turbine plant output. It has been observed that the simulated plant output is less than the existing gas turbine plant output by 5%. Results show that variation of humidity does not affect the gas turbine performance appreciably for all types of fuels. For a decrease of inlet air temperature by 10 °F, net plant output and efficiency have been found to increase by 5 and 2 %, respectively for all fuels, for GT only situation. However, for GT with Fogger scenario, for a decrease of inlet air temperature by 10 °F, net plant output and efficiency have been found to further increase by 3.2 and 1.2 %, respectively for all fuels. For all GT frames with fogger, the net plant output and efficiency are relatively higher as compared to GT only case for all

  16. Solar thermal power plants

    International Nuclear Information System (INIS)

    Schnatbaum, L.

    2009-01-01

    The solar thermal power plant technology, the opportunities it presents and the developments in the market are outlined. The focus is on the technology of parabolic trough power plants, a proven technology for solar power generation on a large scale. In a parabolic trough power plant, trough-shaped mirrors concentrate the solar irradiation onto a pipe in the focal line of the collector. The thermal energy thus generated is used for electricity generation in a steam turbine. Parabolic trough plants can be combined with thermal storage and fossil or biomass fired heat exchangers to generate electricity even when the sun is not shining. Solar Millennium AG in Erlangen has developed the first power plant of this kind in Europe. After two years of construction the plant started operation in Southern Spain in 2008. This one and its sister projects are important steps leading the way for the whole market. The paper also covers the technological challenges, the key components used and the research and development activities concerning this technology. Solar thermal power plants are ideal for covering peak and medium loads in power grids. In hybrid operation they can also cover base-load. The Solar Chimney power plant, another striking technology for the conversion of solar into electric energy, is described briefly. The paper concludes with a look at the future - the import of solar energy from the deserts of North Africa to central Europe. (author)

  17. Power plant chemical technology

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-01

    17 contributions covering topies of fossil fuel combustion, flue gas cleaning, power plant materials, corrosion, water/steam cycle chemistry, monitoring and control were presented at the annual meeting devoted to Power Plant Chemical Technology 1996 at Kolding (Denmark) 4-6 September 1996. (EG)

  18. Nuclear Power Plants. Revised.

    Science.gov (United States)

    Lyerly, Ray L.; Mitchell, Walter, III

    This publication is one of a series of information booklets for the general public published by the United States Atomic Energy Commission. Among the topics discussed are: Why Use Nuclear Power?; From Atoms to Electricity; Reactor Types; Typical Plant Design Features; The Cost of Nuclear Power; Plants in the United States; Developments in Foreign…

  19. NUCLEAR POWER PLANT

    Science.gov (United States)

    Carter, J.C.; Armstrong, R.H.; Janicke, M.J.

    1963-05-14

    A nuclear power plant for use in an airless environment or other environment in which cooling is difficult is described. The power plant includes a boiling mercury reactor, a mercury--vapor turbine in direct cycle therewith, and a radiator for condensing mercury vapor. (AEC)

  20. Impact of structural aging on seismic risk assessment of reinforced concrete structures in nuclear power plants

    International Nuclear Information System (INIS)

    Ellingwood, B.; Song, J.

    1996-03-01

    The Structural Aging Program is addressing the potential for degradation of concrete structural components and systems in nuclear power plants over time due to aging and aggressive environmental stressors. Structures are passive under normal operating conditions but play a key role in mitigating design-basis events, particularly those arising from external challenges such as earthquakes, extreme winds, fires and floods. Structures are plant-specific and unique, often are difficult to inspect, and are virtually impossible to replace. The importance of structural failures in accident mitigation is amplified because such failures may lead to common-cause failures of other components. Structural condition assessment and service life prediction must focus on a few critical components and systems within the plant. Components and systems that are dominant contributors to risk and that require particular attention can be identified through the mathematical formalism of a probabilistic risk assessment, or PRA. To illustrate, the role of structural degradation due to aging on plant risk is examined through the framework of a Level 1 seismic PRA of a nuclear power plant. Plausible mechanisms of structural degradation are found to increase the core damage probability by approximately a factor of two

  1. Impact of the legislative environment on an individual operating a photovoltaic power plant

    Directory of Open Access Journals (Sweden)

    Michaela Baranyková

    2010-01-01

    Full Text Available Operation of a photovoltaic power plant by an individual is a business activity according to a special regulation. For this activity it is necessary to have a “Licence for doing business in energy sectors”, which provides authorisation to do business in this sector and replaces the traditional Trade Licence. The Licence is issued by the Energy Regulatory Office, through which the Organisation Identification Number (Administrative Id. No. is issued.All these issues are however closely associated with the legislative environment, which is very unclear in the Czech Republic, and it is very difficult to estimate in what direction it will develop. In this connection it is appropriate to present a work definition of the term “legislatively uncertain environment”. The issues connected with these topics can be divided into three areas, namely law, accounting and taxes. This environment is highly unstable for the decision making process of an individual, and it is not easy to determine whether the terms and conditions will remain as they are or if they are changed within several months, not speaking about the fact that the recent periods are characterised by the fact that the law regulations use more and more often the principle of retroactivity, and therefore it is not even clear whether the individual makes a decision in the conditions which are set at present or if he or she is retroactively hit by the changes which may be made during a few months and can have a fundamental impact on the individual concerned.

  2. Nuclear power plants

    International Nuclear Information System (INIS)

    Margulova, T.Ch.

    1976-01-01

    The textbook focuses on the technology and the operating characteristics of nuclear power plants equiped with pressurized water or boiling water reactors, which are in operation all over the world at present. The following topics are dealt with in relation to the complete plant and to economics: distribution and consumption of electric and thermal energy, types and equipment of nuclear power plants, chemical processes and material balance, economical characteristics concerning heat and energy, regenerative preheating of feed water, degassing and condenser systems, water supply, evaporators, district heating systems, steam generating systems and turbines, coolant loops and pipes, plant siting, ventilation and decontamination systems, reactor operation and management, heat transfer including its calculation, design of reactor buildings, and nuclear power plants with gas or sodium cooled reactors. Numerous technical data of modern Soviet nuclear power plants are included. The book is of interest to graduate and post-graduate students in the field of nuclear engineering as well as to nuclear engineers

  3. MINIMIZATION OF IMPACTS PERTAINING TO EXTERNAL AND INTERNAL ENERGY SECURITY THREATS OF THERMAL POWER PLANTS

    Directory of Open Access Journals (Sweden)

    V. N. Nagornov

    2012-01-01

    Full Text Available The paper contains a classification of internal and external threats for thermal power plants and recommendations on minimization of these risks. A set of concrete measures aimed at ensuring TPP energy security has been presented in the paper. The system comprises preventive measures aimed at reducing the possibilities of emergence and implementation of internal and external threats. The system also presupposes to decrease susceptibility of fuel- and energy supply systems to the threats, and application of liquidation measures that ensure elimination of emergency situation consequences and restoration of the conditions concerning fuel- and power supply to consumers.

  4. Evaluation of Millstone Nuclear Power Plant, Environmental Impact prediction, based on monitoring programs

    International Nuclear Information System (INIS)

    Gore, K.L.; Thomas, J.M.; Kannberg, L.D.; Watson, D.G.

    1977-02-01

    This report evaluates the nonradiological monitoring program at Millstone Nuclear Power Plant. Both operational as well as preoperational monitoring programs were analyzed to produce long-term (5 yr or longer) data sets, where possible. In order to determine the effectiveness of these monitoring programs, the appropriate data sets have to be analyzed by the appropriate statistical analysis. Thus, both open literature and current statistical analysis being developed at Pacific Northwest Laboratories (PNL) were employed in data analysis

  5. A study on methodologies for assessing safety critical network's risk impact on Nuclear Power Plant

    International Nuclear Information System (INIS)

    Lim, T. J.; Lee, H. J.; Park, S. K.; Seo, S. J.

    2006-08-01

    The objectives of this project is to investigate and study existing reliability analysis techniques for communication networks in order to develop reliability analysis models for Nuclear Power Plant's safety-critical networks. It is necessary to make a comprehensive survey of current methodologies for communication network reliability. Major outputs of the first year study are design characteristics of safety-critical communication networks, efficient algorithms for quantifying reliability of communication networks, and preliminary models for assessing reliability of safety-critical communication networks

  6. Citizens' views about the proposed Hartsville Nuclear Power Plant: a preliminary report of potential social impacts

    International Nuclear Information System (INIS)

    Schuller, C.R.; Fowler, J.R.; Mattingly, T.J. Jr.; Sundstrom, E.; Lounsbury, J.; Passino, E.M.; Dowell, D.A.; Hutton, B.J.

    1975-05-01

    Preliminary results of a survey of public attitudes toward a proposed nuclear power plant facility at Hartsville, Tennessee are summarized. The purpose of the study was to aid in developing better methods for understanding the social consequences of energy facility development. The report is based on data obtained in interviews with 350 randomly selected respondents administered in Trousdale County, Tennessee during February 1975. (U.S.)

  7. Evaluation of Millstone Nuclear Power Plant, Environmental Impact prediction, based on monitoring programs

    Energy Technology Data Exchange (ETDEWEB)

    Gore, K.L.; Thomas, J.M.; Kannberg, L.D.; Watson, D.G.

    1977-02-01

    This report evaluates the nonradiological monitoring program at Millstone Nuclear Power Plant. Both operational as well as preoperational monitoring programs were analyzed to produce long-term (5 yr or longer) data sets, where possible. In order to determine the effectiveness of these monitoring programs, the appropriate data sets have to be analyzed by the appropriate statistical analysis. Thus, both open literature and current statistical analysis being developed at Pacific Northwest Laboratories (PNL) were employed in data analysis.

  8. Impact of a coal fired power plant on 226Ra activity level in sea water

    International Nuclear Information System (INIS)

    Marovic, G.; Sencar, J.

    1999-01-01

    The paper deals with radioactivity contamination originating from a coal fired power plant which, due to its location, may present a remarkable environmental problem. The plant is situated in a bay of the Adriatic close to the densely populated area with highly developed touristic activity. Its operation may cause significant damage to rich marine ecosystem characteristic for this part of the Croatian Adriatic as well as endanger urban and touristic developmental prospects of the area. Investigations of coal used in regular plant operation and of solid incombustible ash and slag showed increased natural radioactivity levels which may cause general environmental contamination of the bay as well as contamination of the marine environment of this part of the Croatian Adriatic

  9. Investigation of the impact of main control room digitalization on operators cognitive reliability in nuclear power plants.

    Science.gov (United States)

    Zhou, Yong; Mu, Haiying; Jiang, Jianjun; Zhang, Li

    2012-01-01

    Currently, there is a trend in nuclear power plants (NPPs) toward introducing digital and computer technologies into main control rooms (MCRs). Safe generation of electric power in NPPs requires reliable performance of cognitive tasks such as fault detection, diagnosis, and response planning. The digitalization of MCRs has dramatically changed the whole operating environment, and the ways operators interact with the plant systems. If the design and implementation of the digital technology is incompatible with operators' cognitive characteristics, it may have negative effects on operators' cognitive reliability. Firstly, on the basis of three essential prerequisites for successful cognitive tasks, a causal model is constructed to reveal the typical human performance issues arising from digitalization. The cognitive mechanisms which they impact cognitive reliability are analyzed in detail. Then, Bayesian inference is used to quantify and prioritize the influences of these factors. It suggests that interface management and unbalanced workload distribution have more significant impacts on operators' cognitive reliability.

  10. Italian steam power plants

    Energy Technology Data Exchange (ETDEWEB)

    von Rautenkranz, J

    1939-01-01

    A brief history of geothermal power production in Italy is presented. Boric acid has been produced on an industrial scale since 1818. The first electrical power was generated in 1904, and by 1939 the output of geothermal power plants had reached 500 GWh, with major expansion of facilities planned.

  11. The importance of meteorology in the environmental impacts assessment of nuclear power plants: scenarios studies using geographic information system

    International Nuclear Information System (INIS)

    Leao, I.L.B.; Biagio, R.M.S.; Costa, E.M.; Alves, R.N.

    1999-01-01

    The Brazilian Nuclear Power Plant (CNAAA) is located in a very complex region of the state of Rio de Janeiro. The environmental impact caused by the normal operation of such installation can be better evaluated by using an integrated approach, in which a geographical information system plays a very important role. In this study, environmental scenarios are integrated with some extreme and representative meteorological situations. (author)

  12. Study on the impact of the engineering energy gain and the FPC mass power density on the generation cost of fusion power plant

    International Nuclear Information System (INIS)

    Huang Desuo; Wu Yican

    2004-01-01

    The impact of the engineering energy gain and the fusion-power-core (FPC) mass power density (MPD) on the generation cost of fusion power plant are analyzed based on the economic elasticity approach in this paper. From the functions describing the relationship of the generation cost with the engineering energy gain and the MPD, the elasticity coefficients of the generation cost with the engineering energy gain and the MPD have been derived respectively to analyze their sensitivity to the generation cost and the MPD to the generation cost decreases with increasing the engineering energy gain or the MPD. (authors)

  13. Concentrated solar power plants impact on PV penetration level and grid flexibility under Egyptian climate

    Science.gov (United States)

    Moukhtar, Ibrahim; Elbaset, Adel A.; El Dein, Adel Z.; Qudaih, Yaser; Mitani, Yasunori

    2018-05-01

    Photovoltaic (PV) system integration in the electric grid has been increasing over the past decades. However, the impact of PV penetration on the electric grid, especially during the periods of higher and lower generation for the solar system at the middle of the day and during cloudy weather or at night respectively, limit the high penetration of solar PV system. In this research, a Concentrated Solar Power (CSP) with Thermal Energy Storage (TES) has been aggregated with PV system in order to accommodate the required electrical power during the higher and lower solar energy at all timescales. This paper analyzes the impacts of CSP on the grid-connected PV considering high penetration of PV system, particularly when no energy storages in the form of batteries are used. Two cases have been studied, the first when only PV system is integrated into the electric grid and the second when two types of solar energy (PV and CSP) are integrated. The System Advisor Model (SAM) software is used to simulate the output power of renewable energy. Simulation results show that the performance of CSP has a great impact on the penetration level of PV system and on the flexibility of the electric grid. The overall grid flexibility increases due to the ability of CSP to store and dispatch the generated power. In addition, CSP/TES itself has inherent flexibility. Therefore, CSP reduces the minimum generation constraint of the conventional generators that allows more penetration of the PV system.

  14. Draft environmental impact report. California Department of Water Resources, Bottle Rock geothermal power plant, Lake County, CA

    Energy Technology Data Exchange (ETDEWEB)

    1979-12-01

    The California Department of Water Resources (DWR) proposes to construct the Bottle Rock power plant, a 55 MW geothermal power plant, at The Geysers Known Geothermal Resource Area (KGRA). The plant is projected to begin operation in April of 1983, and will be located in Lake County near the Sonoma County line on approximately 7.2 acres of the Francisco leasehold. The steam to operate the power plant, approximately 1,000,000 pounds/h, will be provided by McCulloch Geothermal Corporation. The power plant's appearance and operation will be basically the same as the units in operation or under construction in the KGRA. The power plant and related facilities will consist of a 55 MW turbine generator, a 1.1 mile (1.81 km) long transmission line, a condensing system, cooling tower, electrical switchyard, gas storage facility, cistern, and an atmospheric emission control system. DWR plans to abate hydrogen sulfide (H/sub 2/S) emissions through the use of the Stretford Process which scrubs the H/sub 2/S from the condenser vent gas stream and catalytically oxides the gas to elemental sulfur. If the Stretford Process does not meet emission limitations, a secondary H/sub 2/S abatement system using hydrogen peroxide/iron catalyst is proposed. The Bottle Rock project and other existing and future geothermal projects in the KGRA may result in cumulative impacts to soils, biological resources, water quality, geothermal steam resources, air quality, public health, land use, recreation, cultural resources, and aesthetics.

  15. Evaluation of Monticello Nuclear Power Plant, Environmental Impact Prediction, based on monitoring programs

    International Nuclear Information System (INIS)

    Gore, K.L.; Thomas, J.M.; Kannberg, L.D.; Watson, D.G.

    1976-11-01

    This report evaluates quantitatively the nonradiological environmental monitoring programs at Monticello Nuclear Generating Plant. The general objective of the study is to assess the effectiveness of monitoring programs in the measurement of environmental impacts. Specific objectives include the following: (1) Assess the validity of environmental impact predictions made in the Environmental Statement by analysis of nonradiological monitoring data; (2) evaluate the general adequacy of environmental monitoring programs for detecting impacts and their responsiveness to Technical Specifications objectives; (3) assess the adequacy of preoperational monitoring programs in providing a sufficient data base for evaluating operational impacts; (4) identify possible impacts that were not predicted in the environmental statement and identify monitoring activities that need to be added, modified or deleted; and (5) assist in identifying environmental impacts, monitoring methods, and measurement problems that need additional research before quantitative predictions can be attempted. Preoperational as well as operational monitoring data were examined to test the usefulness of baseline information in evaluating impacts. This included an examination of the analytical methods used to measure ecological and physical parameters, and an assessment of sampling periodicity and sensitivity where appropriate data were available

  16. The impact of twenty years of noise research on nuclear power plant design, instrumentation and control

    International Nuclear Information System (INIS)

    Kemeny, L.G.

    1975-01-01

    Early investigations demonstrated that time constants and the dynamic characteristics of low energy nuclear systems could be elegantly determined by correlation of spectral analysis of fluctuating signals from ion chambers and proportional counters. Analyses of the time series information and the multi-filtering operations in the frequency domain were time consuming and tedious projects due to the lack of suitable data processing equipment. During the last decade, the significant advances were the recognition of the advantages of the two-channel cross-correlation technique and the realisation that the dynamic behaviour of nuclear power plant at power could be monitored and studied in depth by the cross-correlation of mechanical, thermal and hydrodynamic signals with neutronic information. The former concept led to the development of theoretical models for spatial and energy-dependent noise fields within a nuclear system. The latter opened a floodgate of potential advances in nuclear power plant design optimization, control and safety instrumentation, and control and safety diagnostic systems. (U.K.)

  17. 4. Nuclear power plant component failures

    International Nuclear Information System (INIS)

    1990-01-01

    Nuclear power plant component failures are dealt with in relation to reliability in nuclear power engineering. The topics treated include classification of failures, analysis of their causes and impacts, nuclear power plant failure data acquisition and processing, interdependent failures, and human factor reliability in nuclear power engineering. (P.A.). 8 figs., 7 tabs., 23 refs

  18. Cost-benefit analysis for environmental impacts and radwaste system for nuclear power plant

    International Nuclear Information System (INIS)

    Mun, K.N.; Yook, C.C.

    1982-01-01

    During operation of nuclear power plant, radioactive material is inevitably formed. This radioactive material must be safely processed by radwaste system so that essentially zero activity is released to the environment. However zero released activity is not really practicable and population doses resulted from released activity are proportional to total annual cost for the radwaste system. In this study, cost-benefit analysis for the radwaste system of the Korean Nuclear Units 5 and 6 is performed to evaluate the optimization between the total annual cost for the radwaste system and population doses within 80 km from the plants. From the analysis, the following results are obtained; 1. the total population dose is estimated 4.04 x 10 3 man-rem/year, 2. total annual cost for the radwaste system is required $ 1.74 x 10 6 , 3. cost-benefit ratio is estimated $ 429/man-rem. (Author)

  19. Nuclear power plant construction

    International Nuclear Information System (INIS)

    Lima Moreira, Y.M. de.

    1979-01-01

    The legal aspects of nuclear power plant construction in Brazil, derived from governamental political guidelines, are presented. Their evolution, as a consequence of tecnology development is related. (A.L.S.L.) [pt

  20. Nuclear power plant decommissioning

    International Nuclear Information System (INIS)

    Yaziz Yunus

    1986-01-01

    A number of issues have to be taken into account before the introduction of any nuclear power plant in any country. These issues include reactor safety (site and operational), waste disposal and, lastly, the decommissioning of the reactor inself. Because of the radioactive nature of the components, nuclear power plants require a different approach to decommission compared to other plants. Until recently, issues on reactor safety and waste disposal were the main topics discussed. As for reactor decommissioning, the debates have been academic until now. Although reactors have operated for 25 years, decommissioning of retired reactors has simply not been fully planned. But the Shippingport Atomic Power Plant in Pennysylvania, the first large scale power reactor to be retired, is now being decommissioned. The work has rekindled the debate in the light of reality. Outside the United States, decommissioning is also being confronted on a new plane. (author)

  1. Advanced stellarator power plants

    International Nuclear Information System (INIS)

    Miller, R.L.

    1994-01-01

    The stellarator is a class of helical/toroidal magnetic fusion devices. Recent international progress in stellarator power plant conceptual design is reviewed and comparisons in the areas of physics, engineering, and economics are made with recent tokamak design studies

  2. International power plant business

    Energy Technology Data Exchange (ETDEWEB)

    Grohe, R.

    1986-03-03

    At the Brown Boveri press seminar 'Energy' in Baden-Baden Rainer Grohe, member of the Brown Boveri board, Mannheim, gave a survey of the activities on the international power plant market in recent years. He showed the vacuities which must be taken into account in this sector today. The drastic escalation of demands on power plant suppliers has lead not to a reduction of protagonists but to an increase. (orig.).

  3. Radiological impact from spanish coal power plants.2.- Dispersion model for deconcentration calculations

    International Nuclear Information System (INIS)

    Alvarez, M.C.; Garzon, L.

    1990-01-01

    In this paper a practical dispersion model is presented, which permits to calculate, in Spain, the concentration of natural radionuclides released to the atmosphere from coal power plants. To apply the model it is necessary to know the following data: emission rates, dry deposition velocity, scavenging coefficient, mixing layer height, together with climatological frequency data relating to wind speed and wind direction (to determinate trajectories from a given source) in the areas examined. Meteorological data can be obtained from meteorological stations across Spain. (Author)

  4. Offshore atomic power plants

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Various merits of offshore atomic power plants are illustrated, and their systems are assessed. The planning of the offshore atomic power plants in USA is reviewed, and the construction costs of the offshore plant in Japan were estimated. Air pollution problem may be solved by the offshore atomic power plants remarkably. Deep water at low temperature may be advantageously used as cooling water for condensers. Marine resources may be bred by building artificial habitats and by providing spring-up equipments. In the case of floating plants, the plant design can be standardized so that the construction costs may be reduced. The offshore plants can be classified into three systems, namely artificial island system, floating system and sea bottom-based system. The island system may be realized with the present level of civil engineering, but requires the development of technology for the resistance of base against earthquake and its calculation means. The floating system may be constructed with conventional power plant engineering and shipbuilding engineering, but the aseismatic stability of breakwater may be a problem to be solved. Deep water floating system and deep water submerging system are conceivable, but its realization may be difficult. The sea bottom-based system with large caissons can be realized by the present civil engineering, but the construction of the caissons, stability against earthquake and resistance to waves may be problems to be solved. The technical prediction and assessment of new plant sites for nuclear power plants have been reported by Science and Technology Agency in 1974. The construction costs of an offshore plant has been estimated by the Ministry of International Trade and Industry to be yen71,026/kW as of 1985. (Iwakiri, K.)

  5. Power plants 2010. Lectures

    International Nuclear Information System (INIS)

    2010-01-01

    The proceedings include the following lectures: Facing the challenges - new structures for electricity production. Renewable energies in Europe - chances and challenges. Nuclear outlook in the UK. Sustainable energy for Europe. Requirements of the market and the grid operator at the electricity production companies. Perspectives for the future energy production. Pumped storage plants - status and perspectives. Nuclear power/renewable energies -partners or opponents? New fossil fired power stations in Europe - status and perspectives. Nuclear energy: outlook for new build and lifetime extension in Europe. Biomass in the future European energy market - experiences for dong energy. Meeting the EU 20:20 renewable energy targets: the offshore challenges. DESERTEC: sustainable electricity for Europe, Middle East and North Africa. New power plants in Europe - a challenge for project and quality management. Consideration of safely in new build activities of power plants. Challenges to an integrated development in Maasvlakte, Netherlands. Power enhancement in EnBW power plants. Operational experiences of CCS pilot plants worldwide. Two years of operational experiences with Vattenfall's oxyfuel pilot plant. Pre-conditions for CCS. Storage technologies for a volatile generation. Overview: new generation of gas turbines.

  6. Collateral effects of renewable energies deployment in Spain: Impact on thermal power plants performance and management

    International Nuclear Information System (INIS)

    Moreno, Fermin; Martinez-Val, Jose M.

    2011-01-01

    The quest for renewable energy sources has been strong in Spain for a couple of decades, and has produced outstanding results, notably in windpower. Solar technologies also had a prompt response to the promoting legislation of 2007. This evolution has generated side effects in the electricity generation system as a whole, and all this phenomenology is analysed in this paper under the consideration of the three objectives theoretically guiding electricity policy nowadays: security of supply (at macro and micro level), environmental quality, and economic competitiveness. The analysis points out some unbalance among the objectives, which can evolve to a scenario where back-up power is going to be a critical point for the stability of the system. Such a back-up service will surely be provided by gas-fired combined cycles (GFCC). The estimated projections of the generation system show that the required back-up power will grow about 8-9 GW by year 2020, for complying with the objective of attaining a share of 40% renewable electricity. However, collateral effects as the decline in the load factor of GFCC, as well as a reduction in spot price of electricity, can cast many doubts about the feasibility to reach that back-up power level. - Highlights: → Renewable energy will not match power peaks with high level of confidence. → Fossil thermal plants have become back-up systems to substitute for renewable energy. → Estimations show that 8-9 GW of additional combined cycles will be needed by 2020. → Electricity from renewable energy will provoke long periods of low spot prices. → Lack of economic feasibility of thermal plants threatens long term security of supply.

  7. Power Plant Replacement Study

    Energy Technology Data Exchange (ETDEWEB)

    Reed, Gary

    2010-09-30

    This report represents the final report for the Eastern Illinois University power plant replacement study. It contains all related documentation from consideration of possible solutions to the final recommended option. Included are the economic justifications associated with the chosen solution along with application for environmental permitting for the selected project for construction. This final report will summarize the results of execution of an EPC (energy performance contract) investment grade audit (IGA) which lead to an energy services agreement (ESA). The project includes scope of work to design and install energy conservation measures which are guaranteed by the contractor to be self-funding over its twenty year contract duration. The cost recovery is derived from systems performance improvements leading to energy savings. The prime focus of this EPC effort is to provide a replacement solution for Eastern Illinois University's aging and failing circa 1925 central steam production plant. Twenty-three ECMs were considered viable whose net impact will provide sufficient savings to successfully support the overall project objectives.

  8. Power Plant Replacement Study

    Energy Technology Data Exchange (ETDEWEB)

    Reed, Gary

    2010-09-30

    This report represents the final report for the Eastern Illinois University power plant replacement study. It contains all related documentation from consideration of possible solutions to the final recommended option. Included are the economic justifications associated with the chosen solution along with application for environmental permitting for the selected project for construction. This final report will summarize the results of execution of an EPC (energy performance contract) investment grade audit (IGA) which lead to an energy services agreement (ESA). The project includes scope of work to design and install energy conservation measures which are guaranteed by the contractor to be self-funding over its twenty year contract duration. The cost recovery is derived from systems performance improvements leading to energy savings. The prime focus of this EPC effort is to provide a replacement solution for Eastern Illinois University’s aging and failing circa 1925 central steam production plant. Twenty-three ECMs were considered viable whose net impact will provide sufficient savings to successfully support the overall project objectives.

  9. Exploring the potential impact of implementing carbon capture technologies in fossil fuel power plants on regional European water stress index levels

    NARCIS (Netherlands)

    Schakel, W.B.; Pfister, Stephan; Ramirez, C.A.

    Equipping power plants with carbon capture technology can affect cooling demand and water use. This study has explored the potential impact of large scale deployment of power plants with carbon capture technologies on future regional water stress in Europe. A database including 458 of European

  10. 77 FR 29701 - Impact of Construction (Under a Combined License) of New Nuclear Power Plant Units on Operating...

    Science.gov (United States)

    2012-05-18

    ... New Nuclear Power Plant Units on Operating Units at Multi-Unit Sites AGENCY: Nuclear Regulatory... construct and operate new nuclear power plants (NPPs) on multi-unit sites to provide an evaluation of the... License) of New Nuclear Power Plants on Operating Units at Multi-Unit Sites (Package). ML112630039 Federal...

  11. Impact of the Fukushima Daiichi nuclear power plant accident on local community and healthcare services

    International Nuclear Information System (INIS)

    Oikawa, Tomoyoshi

    2013-01-01

    The Soso region of Japan, located in the northern part of the Pacific side of Fukushima Prefecture, has suffered tremendously from widespread damage caused by the earthquake, tsunami and the Fukushima Dai-ichi nuclear power plant accident. Immediately after the disaster it even seemed that the restoration of this region itself would not be possible. However after six months, the Indoor Restriction Order and evacuation orders within a 20 to 30 km zone from the plant, such as the Evacuation-Prepared Area in Case of Emergency, were lifted and all of those restrictions for the planned evaluation zone has been eased in line with the actual conditions of each region. A year and a month after the earthquake, the Caution Zone, which was declared to prohibit the entry to the zone within the 20 km radius from the plant, was lifted. Thus people can now enter as close as 10 km from the plant. Minami-Soma city is an administrative district which had the largest population (approximately 71,500 residents) within the 20 to 30 km zone prior to the earthquake. It was, also, the only district where the evacuation was not conducted by the municipality. The city is now called the Genpatsu frontline district as it is the closest city to the plant where people have continued to live. Due to the damage caused by the earthquake and Tsunami, the city has suffered both from destruction by the tsunami and radiation, and people are still facing numerous problems despite the fact that the city appears to have been restored on its surface. It is very unfortunate that much of the medical data from the region was lost in the confusion after the Great East Japan Earthquake. In this paper various facts after the disaster based on the data left in the So-so region, Minamisoma city, and Minamisoma municipal general hospital are reported. (author)

  12. Impact of the operation of non-displaced feedwater heaters on the performance of Solar Aided Power Generation plants

    International Nuclear Information System (INIS)

    Qin, Jiyun; Hu, Eric; Nathan, Graham J.

    2017-01-01

    Highlights: • Impact of non-displaced feedwater heater on plant’s performance has been evaluated. • Two operation strategies for non-displaced feedwater heater has been proposed. • Constant temperature strategy is generally better. • Constant mass flow rate strategy is suit for rich solar thermal input. - Abstract: Solar Aided Power Generation is a technology in which low grade solar thermal energy is used to displace the high grade heat of the extraction steam in a regenerative Rankine cycle power plant for feedwater preheating purpose. The displaced extraction steam can then expand further in the steam turbine to generate power. In such a power plant, using the (concentrated) solar thermal energy to displace the extraction steam to high pressure/temperature feedwater heaters (i.e. displaced feedwater heaters) is the most popular arrangement. Namely the extraction steam to low pressure/temperature feedwater heaters (i.e. non-displaced feedwater heaters) is not displaced by the solar thermal energy. In a Solar Aided Power Generation plants, when solar radiation/input changes, the extraction steam to the displaced feedwater heaters requires to be adjusted according to the solar radiation. However, for the extraction steams to the non-displaced feedwater heaters, it can be either adjusted accordingly following so-called constant temperature strategy or unadjusted i.e. following so-called constant mass flow rate strategy, when solar radiation/input changes. The previous studies overlooked the operation of non-displaced feedwater heaters, which has also impact on the whole plant’s performance. This paper aims to understand/reveal the impact of the two different operation strategies for non-displaced feedwater heaters on the plant’s performance. In this paper, a 300 MW Rankine cycle power plant, in which the extraction steam to high pressure/temperature feedwater heaters is displaced by the solar thermal energy, is used as study case for this purpose. It

  13. Economic impact of latent heat thermal energy storage systems within direct steam generating solar thermal power plants with parabolic troughs

    International Nuclear Information System (INIS)

    Seitz, M.; Johnson, M.; Hübner, S.

    2017-01-01

    Highlights: • Integration of a latent heat thermal energy storage system into a solar direct steam generation power cycle. • Parametric study of solar field and storage size for determination of the optimal layout. • Evaluation of storage impact on the economic performance of the solar thermal power plant. • Economic comparison of new direct steam generation plant layout with state-of-the-art oil plant layout. - Abstract: One possible way to further reduce levelized costs of electricity of concentrated solar thermal energy is to directly use water/steam as the primary heat transfer fluid within a concentrated collector field. This so-called direct steam generation offers the opportunity of higher operating temperatures and better exergy efficiency. A technical challenge of the direct steam generation technology compared to oil-driven power cycles is a competitive storage technology for heat transfer fluids with a phase change. Latent heat thermal energy storages are suitable for storing heat at a constant temperature and can be used for direct steam generation power plants. The calculation of the economic impact of an economically optimized thermal energy storage system, based on a latent heat thermal energy storage system with phase change material, is the main focus of the presented work. To reach that goal, a thermal energy storage system for a direct steam generation power plant with parabolic troughs in the solar field was thermally designed to determine the boundary conditions. This paper discusses the economic impact of the designed thermal energy storage system based on the levelized costs of electricity results, provided via a wide parametric study. A state-of-the-art power cycle with a primary and a secondary heat transfer fluid and a two-tank thermal energy storage is used as a benchmark technology for electricity generation with solar thermal energy. The benchmark and direct steam generation systems are compared to each other, based respectively

  14. Impact of plant transient response on fuel management strategy at Virginia Power

    International Nuclear Information System (INIS)

    Bucheit, D.M.; Smith, N.A.

    1987-01-01

    Virginia Power has been performing in-house reload core design and safety analysis for several years. These analyses have been in support of North Anna units 1 and 2 and Surry units 1 and 2, all of which are three-loop pressurized water reactor plants designed and built by Westinghouse. Historically, Virginia Power first developed the capability to design and optimize its own core loading patterns in the early 1970's. This development effort was driven by the need to establish in-house control of the fuel management process, thereby ensuring that energy generation requirements are met in an economically optimum fashion. It soon became obvious that reload design and safety analysis processes are so integrally coupled that in order to perform the fuel management function in an effective manner, in-house capability in both areas needed to be developed. After reviewing the spectrum of economic, safety and operational constraints which affect the reload design and analysis process, an integrated model of the process is presented in flow chart format. This is followed by several specific examples which illustrate the interplay between sound fuel management practice and the assurance of plant safety using in-house analysis techniques

  15. Power plant at sea

    International Nuclear Information System (INIS)

    Roggen, M.

    2000-01-01

    Drilling platforms are rather inefficient when it comes to their own power supply. In view of ecotax and their environmental image, the offshore industry particularly the Norwegians is highly committed to changing this situation. An efficient power plant, specially designed for the offshore industry, might just prove to be the answer to their prayers

  16. The future of integrated coal gasification combined cycle power plants

    International Nuclear Information System (INIS)

    Mueller, R.; Termuehlen, H.

    1991-01-01

    This paper examines the future of integrated coal gasification combined cycle (IGCC) power plants as affected by various technical, economical and environmental trends in power generation. The topics of the paper include a description of natural gas-fired combined cycle power plants, IGCC plants, coal gasifier concepts, integration of gasifiers into combined cycle power plants, efficiency, environmental impacts, co-products of IGCC power plants, economics of IGCC power plants, and a review of IGCC power plant projects

  17. Nuclear power plants maintenance

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    Nuclear power plants maintenance now appears as an important factor contributing to the competitivity of nuclea energy. The articles published in this issue describe the way maintenance has been organized in France and how it led to an actual industrial activity developing and providing products and services. An information note about Georges Besse uranium enrichment plant (Eurodif) recalls that maintenance has become a main data not only for power plants but for all nuclear industry installations. (The second part of this dossier will be published in the next issue: vol. 1 January-February 1989) [fr

  18. Nuclear power plant outages

    International Nuclear Information System (INIS)

    1998-01-01

    The Finnish Radiation and Nuclear Safety Authority (STUK) controls nuclear power plant safety in Finland. In addition to controlling the design, construction and operation of nuclear power plants, STUK also controls refuelling and repair outages at the plants. According to section 9 of the Nuclear Energy Act (990/87), it shall be the licence-holder's obligation to ensure the safety of the use of nuclear energy. Requirements applicable to the licence-holder as regards the assurance of outage safety are presented in this guide. STUK's regulatory control activities pertaining to outages are also described

  19. Nuclear Power Plants (Rev.)

    Energy Technology Data Exchange (ETDEWEB)

    Lyerly, Ray L.; Mitchell III, Walter [Southern Nuclear Engineering, Inc.

    1973-01-01

    Projected energy requirements for the future suggest that we must employ atomic energy to generate electric power or face depletion of our fossil-fuel resources—coal, oil, and gas. In short, both conservation and economic considerations will require us to use nuclear energy to generate the electricity that supports our civilization. Until we reach the time when nuclear power plants are as common as fossil-fueled or hydroelectric plants, many people will wonder how the nuclear plants work, how much they cost, where they are located, and what kinds of reactors they use. The purpose of this booklet is to answer these questions. In doing so, it will consider only central station plants, which are those that provide electric power for established utility systems.

  20. LNG plant combined with power plant

    Energy Technology Data Exchange (ETDEWEB)

    Aoki, I; Kikkawa, Y [Chiyoda Chemical Engineering and Construction Co. Ltd., Tokyo (Japan)

    1997-06-01

    The LNG plant consumers a lot of power of natural gas cooling and liquefaction. In some LNG plant location, a rapid growth of electric power demand is expected due to the modernization of area and/or the country. The electric power demand will have a peak in day time and low consumption in night time, while the power demand of the LNG plant is almost constant due to its nature. Combining the LNG plant with power plant will contribute an improvement the thermal efficiency of the power plant by keeping higher average load of the power plant, which will lead to a reduction of electrical power generation cost. The sweet fuel gas to the power plant can be extracted from the LNG plant, which will be favorable from view point of clean air of the area. (Author). 5 figs.

  1. LNG plant combined with power plant

    International Nuclear Information System (INIS)

    Aoki, I.; Kikkawa, Y.

    1997-01-01

    The LNG plant consumers a lot of power of natural gas cooling and liquefaction. In some LNG plant location, a rapid growth of electric power demand is expected due to the modernization of area and/or the country. The electric power demand will have a peak in day time and low consumption in night time, while the power demand of the LNG plant is almost constant due to its nature. Combining the LNG plant with power plant will contribute an improvement the thermal efficiency of the power plant by keeping higher average load of the power plant, which will lead to a reduction of electrical power generation cost. The sweet fuel gas to the power plant can be extracted from the LNG plant, which will be favorable from view point of clean air of the area. (Author). 5 figs

  2. Nuclear power plants and the environment

    Energy Technology Data Exchange (ETDEWEB)

    Barabas, K [Ceskoslovenska Komise pro Atomovou Energii, Prague

    1978-05-01

    The environmental impacts are compared of conventional coal-fired and oil-fired power plants and of nuclear power plants. The values are compared of SO/sub 2/, NO/sub 2/, ash and soot emissions with /sup 133/Xe and /sup 85/Kr fission products release and the requirement for air for diluting these emissions in the atmosphere is assessed. Also compared are thermal pollution from an oil-fired power plant and from PWR and fast reactor power plants. The conclusion is arrived at that nuclear energy can solve the problem of increasing demand for electric and heat power while reducing negative environmental impacts.

  3. Nuclear power plants and the environment

    International Nuclear Information System (INIS)

    Barabas, K.

    1978-01-01

    The environmental impacts are compared of conventional coal-fired and oil-fired power plants and of nuclear power plants. The values are compared of SO 2 , NO 2 , ash and soot emmisions with 133 Xe and 85 Kr fission products release and the requirement for air for diluting these emissions in the atmosphere is assessed. Also compared are thermal pollution from an oil-fired power plant and from PWR and fast reactor power plants. The conclusion is arrived at that nuclear energy can solve the problem of increasing demand for electric and heat power while reducing negative environmental impacts. (O.K.)

  4. Evaluation of the usefulness of ecological simulation models in power plant impact assessment

    International Nuclear Information System (INIS)

    Swartzman, G.L.; Haar, R.T.; McKenzie, D.H.

    1981-05-01

    Comparisons were made of the equations, rationale, data sources and parameter values of 26 simulation models of fish and zooplankton population dynamics and energetics and results were compared in standard notation and units, process by process. The major process categories considered were consumption, predation, metabolic processes, assimilation, growth, fecundity, recruitment and mortality. A model simulation language, AEGIS (Aquatic Ecosystem General Impact Simulator) was built to compare model equations process by process allowing convenient interchange of model equations for any process module. This simulator was parameterized to a test site, Lake Keowee, South Carolina, on which resides the Oconee Nuclear Power Station. Model parameter estimation and comparison of these models with biological monitoring data allows eveluation of ecosystem models from the standpoint of prediction of behavior under normal and perturbed conditions, organization of data into an ecosystem framework, and evaluation of data to address impact questions

  5. Dispatchable Solar Power Plant Project

    Energy Technology Data Exchange (ETDEWEB)

    Price, Henry [Solar Dynamics LLC, Broomfield, CO (United States)

    2018-01-31

    As penetration of intermittent renewable power increases, grid operators must manage greater variability in the supply and demand on the grid. One result is that utilities are planning to build many new natural gas peaking power plants that provide added flexibility needed for grid management. This report discusses the development of a dispatchable solar power (DSP) plant that can be used in place of natural gas peakers. Specifically, a new molten-salt tower (MST) plant has been developed that is designed to allow much more flexible operation than typically considered in concentrating solar power plants. As a result, this plant can provide most of the capacity and ancillary benefits of a conventional natural gas peaker plant but without the carbon emissions. The DSP system presented was designed to meet the specific needs of the Arizona Public Service (APS) utility 2017 peaking capacity request for proposals (RFP). The goal of the effort was to design a MST peaker plant that had the operational capabilities required to meet the peaking requirements of the utility and be cost competitive with the natural gas alternative. The effort also addresses many perceived barriers facing the commercial deployment of MST technology in the US today. These include MST project development issues such as permitting, avian impacts, visual impacts of tower CSP projects, project schedule, and water consumption. The DSP plant design is based on considerable analyses using sophisticated solar system design tools and in-depth preliminary engineering design. The resulting DSP plant design uses a 250 MW steam power cycle, with solar field designed to fit on a square mile plot of land that has a design point thermal rating of 400 MWt. The DSP plant has an annual capacity factor of about 16% tailored to deliver greater than 90% capacity during the critical Arizona summer afternoon peak. The table below compares the All-In energy cost and capacity payment of conventional combustion turbines

  6. Radiological impact of the storage of solid wastes from coal-fored power plants

    International Nuclear Information System (INIS)

    Hugon, J.; Caries, J.C.; Patellis, A.; Roussel, S.

    1983-01-01

    Solid wastes from the coal-fired power plant of GARDANNE are stared in piles, outside near the unit. The coal contains a high proportion of sulfur, so the storage pile is a very reducing middle. The radium coming from the ore, which is mostly retained in the bottom ashes, could then be solubilized again, by physicochemical processes, leached by the rain and reach the nearest population through the food-chain pathways. Leaching-tests where made with three sampling series. The measurement datas show that only 15% of the 226 Ra can be solved and that the Ra 226 observed concentrations in vegetal samples come mostly from transportation of dust by the wind [fr

  7. 76 FR 1469 - Calvert Cliffs Nuclear Power Plant, LLC; Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2...

    Science.gov (United States)

    2011-01-10

    ... Nuclear Power Plant, LLC; Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2 Environmental Assessment... Plant, LLC, the licensee, for operation of the Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2... Impact Statement for License Renewal of Nuclear Plants, Calvert Cliffs Nuclear Power Plant (NUREG-1437...

  8. Assessing the impact of primary measures for NOx reduction on the thermal power plant steam boiler

    International Nuclear Information System (INIS)

    Stupar, Goran; Tucaković, Dragan; Živanović, Titoslav; Belošević, Srdjan

    2015-01-01

    The European normatives prescribe content of 200 mg/Nm 3 NO x for pulverized coal combusting power plants. In order to reduce content of NO x in Serbian thermal power plant (TPP) 'Kostolac B' it's necessary to implement particular measures until 2016. The mathematical model of lignite combustion in the steam boiler furnace is defined and applied to analyze the possibility of implementing certain primary measures for reducing nitrogen oxides and their effects on the steam boiler operation. This model includes processes in the coal-fired furnace and defines radiating reactive two-phase turbulent flow. The model of turbulent flow also contains sub-model of fuel and thermal NO x formation and destruction. This complex mathematical model is related to thermal and aerodynamic calculations of the steam boiler within a unified calculation system in order to analyze the steam boiler overall work. This system provides calculations with a number of influential parameters. The steam boiler calculations for unit 1 (350 MWe) of TPP 'Kostolac B' are implemented for existing and modified combustion system in order to achieve effective, reliable and ecological facility work. The paper presents the influence analysis of large number of parameters on the steam boiler operation with an accepted concept of primary measures. Presented system of calculations is verified against measurements in TPP 'Kostolac B'. - Highlights: • Modern steam boilers need to operate according to ecological standards. • Possibility of applying some of the primary measures of NO x reduction. • Conventional calculations have no possibility to estimate sub-stoichiometric combustion. • Develop a new method of connecting the calculations. • Analysis shows the most favorable operation boiler regime (efficiency and ecology)

  9. The impact of a hydroelectric power plant on the sediment load in downstream water bodies, Svartisen, northern Norway.

    Science.gov (United States)

    Bogen, J; Bønsnes, T E

    2001-02-05

    When the Svartisen hydroelectric power plant was put into operation, extensive sediment pollution was observed in the downstream fjord area. This paper discusses the impact of the power plant and the contribution from various sources of sediment. Computation of the sediment load was based on samples collected one to four times per day. Grain size distribution analyses of suspended sediments were carried out and used as input in a routing model to study the movement of sediments through the system. Suspended sediment delivered to the fjord before the power station was constructed was measured as 8360 metric tons as an annual mean for a 12-year period. During the years 1995-1996 when the power plant was operating, the total suspended load through the power station was measured as 32609 and 30254 metric tons, respectively. Grain size distribution analyses indicate a major change in the composition of the sediments from 9% clay before the power plant was operative to 50-60% clay afterwards. This change, together with the increase in sediment load, is believed to be one of the main causes of the drastic reduction in secchi depths in the fjord. The effect of the suspended sediment load on the fjord water turbidity was evaluated by co-plotting secchi depth and power station water discharge. Measurements during 1995 and 1996 showed that at the innermost of these locations the water failed to attain the minimum requirement of 2 m secchi depth. In later years secchi depths were above the specified level. In 1997 and 1998 the conditions improved. At the more distal locality, the conditions were acceptable with only a few exceptions. A routing model was applied to data acquired at a location 2 km from the power station in order to calculate the contributions from various sediment sources. This model indicated that the contribution from reservoir bed erosion dominated in 1994 but decreased significantly in 1995. Future operation of the power station will mostly take place with

  10. Impact of operational frequency overvoltage transients on nuclear power plant supply systems

    International Nuclear Information System (INIS)

    Aziz, Michael; Klipfel, Volkher; Behrens, Joerg; Trumm, Karl-Heinz; Bresler, Markus

    2008-01-01

    During the Forsmark-1 event from 25 th July 2006 a regular transient after load shedding caused serious impact to the power supply system due to an improper setting of the UPS protection devices. The applicability of the main security issue to German NPPs could be excluded. Nevertheless the event motivated the launch of a detailed analysis program on overvoltage transients. One main issue within this program was the study of overvoltage transients in the operational frequency range. The program was organized as a common project of the German operators with input from the authorities and the consultants, managed within the VGB (''Vereinigung der Grosskraftwerksbetreiber''). More general information to the ''VGB program'' can be found in [1, 2]. A generic model of the power supply and its protection system, the generator and the turbine turned out to be an efficient analysis approach. In a first step, the possible sources (initiating events) for overvoltage transients are identified. The scenarios resulting from the considered initiating events are evaluated with respect to their potential for causing damage in the station power supply system. In a second step those scenarios are excluded from further consideration, which can be categorized as fully covered by the design basis even under assumption with most conservative boundary conditions. In a third step the remaining scenarios for the covering transient are identified. The boundary conditions and failure postulates are assumed conservatively, but with respect to reasonable probabilistic limits. Finally the dynamics of the covering transient is simulated. (orig.)

  11. Identification of the impacts of maintenance and testing upon the safety of LWR power plants. Final report

    International Nuclear Information System (INIS)

    Husseiny, A.A.; Sabri, Z.A.; Turnage, J.J.

    1980-04-01

    The present study was designed to identify the impact of maintenance and testing (M and T) upon the safety of LWR power plants. The study involved data extraction from various sources reporting safety-related and operation-related nuclear power plant experience. Primary sources reviewed, including Licensee Event Reports (LER's) submitted to the NRC, revealed that only ten percent of events reported could be identified as M and T problems. The collected data were collated in a manner that would allow identification of principal types of problems which are associated with the performance of M and T tasks in LWR power plants. Frequencies of occurrence of events and their general endemic nature were analyzed using data clustering and pattern recognition techniques, as well as chi-square analyses for sparse contingency tables. The results of these analyses identified seven major categories of M and T error modes which were related to individual facilities and reactor type. Data review indicated that few M and T problems were directly related to procedural inadequacies, with the majority of events being attributable to human error

  12. The dynamic response of the containment of the Qinshan nuclear power plant to the aircraft impact loading

    International Nuclear Information System (INIS)

    Zuo Jiahong; Han Liangbi; Xia Zufeng

    1991-08-01

    The structural response of the containment of the Qinshan Nuclear Power Plant under the standard-load-function to aircraft impact has been analyzed by using the ADINA code considering an axisymmetric continuum model, which is assumed a mixed-model for the steel-concrete mixture. It consists of 179 four-node isoparametric concrete elements and 118 steel elements. In order to obtain optimum results, the nonlinear behavior of materials and structures, dynamic modes of failure and damage have been considered in the numerical solution. The coordinate system is based on the total Lagrangian formulation. The F.E. system has been solved using an incremental interactions (BFGS method) with 600 steps totally. A discussion of the overall behavior of the containment for the aircraft impact loading, especially the nonlinear behavior of the local impacted area is presented

  13. Evaluation of environmental impacts caused by hydroelectric power plants in native forest areas and mitigation measures

    International Nuclear Information System (INIS)

    Ramalho, Cyro Pinheiro

    1992-01-01

    The following work has the intention of demonstrating the importance of native forest to the human life, not only through its inherent qualities as something to preserve, but also as a source of great resources, and in particular hydroelectric resource that, by today's necessities are bounded to be explored. The negative effects caused by the implementation of a hydroelectric plant are shown together with the necessity of adoption of measures that would soften the environment impact of it. For the adoption of those measures, many forest studies were proposed in the search for its complete characterization. Each of these studies are duly defined and presented in their general and specific goals. The most adequate methodology is finally recommended. (author). 14 refs

  14. Impacts of accidental radioactive releases to the hydrosphere from floating and land-based nuclear power plants

    International Nuclear Information System (INIS)

    Vollmer, R.H.

    1978-01-01

    To assess the impacts of accidental radioactive releases to the hydrosphere from floating and land-based nuclear power plants, the Liquid Pathway Generic Study was initiated. The objective of this study was to compare the risks associated with releases through the liquid pathway from accidents that may reasonably be expected and those that are very improbable. Consequences were estimated in terms of radiation dose to man from drinking water ingestion, shell-fish and fish flesh consumption, and direct exposure (swimming, beach) as well as long-term effects, such as genetic effects or aquatic species degradation. (author)

  15. Wind power plant

    Energy Technology Data Exchange (ETDEWEB)

    Caneghem, A.E. von

    1975-07-24

    The invention applies to a wind power plant in which the wind is used to drive windmills. The plant consists basically of a vertical tube with a lateral wind entrance opening with windmill on its lower end. On its upper end, the tube carries a nozzle-like top which increases the wind entering the tube by pressure decrease. The wind is thus made suitable for higher outputs. The invention is illustrated by constructional examples.

  16. Radiological Impact Associated to Technologically Enhanced Naturally Occurring Radioactive Materials (TENORM) from Coal-Fired Power Plants Emissions - 13436

    International Nuclear Information System (INIS)

    Dinis, Maria de Lurdes; Fiuza, Antonio; Soeiro de Carvalho, Jose; Gois, Joaquim; Meira Castro, Ana Cristina

    2013-01-01

    Certain materials used and produced in a wide range of non-nuclear industries contain enhanced activity concentrations of natural radionuclides. In particular, electricity production from coal is one of the major sources of increased human exposure to naturally occurring radioactive materials. A methodology was developed to assess the radiological impact due to natural radiation background. The developed research was applied to a specific case study, the Sines coal-fired power plant, located in the southwest coastline of Portugal. Gamma radiation measurements were carried out with two different instruments: a sodium iodide scintillation detector counter (SPP2 NF, Saphymo) and a gamma ray spectrometer with energy discrimination (Falcon 5000, Canberra). Two circular survey areas were defined within 20 km of the power plant. Forty relevant measurements points were established within the sampling area: 15 urban and 25 suburban locations. Additionally, ten more measurements points were defined, mostly at the 20-km area. The registered gamma radiation varies from 20 to 98.33 counts per seconds (c.p.s.) corresponding to an external gamma exposure rate variable between 87.70 and 431.19 nGy/h. The highest values were measured at locations near the power plant and those located in an area within the 6 and 20 km from the stacks. In situ gamma radiation measurements with energy discrimination identified natural emitting nuclides as well as their decay products (Pb-212, Pb-2142, Ra-226, Th-232, Ac-228, Th-234, Pa-234, U- 235, etc.). According to the results, an influence from the stacks emissions has been identified both qualitatively and quantitatively. The developed methodology accomplished the lack of data in what concerns to radiation rate in the vicinity of Sines coal-fired power plant and consequently the resulting exposure to the nearby population. (authors)

  17. Reliability Characteristics of Power Plants

    Directory of Open Access Journals (Sweden)

    Zbynek Martinek

    2017-01-01

    Full Text Available This paper describes the phenomenon of reliability of power plants. It gives an explanation of the terms connected with this topic as their proper understanding is important for understanding the relations and equations which model the possible real situations. The reliability phenomenon is analysed using both the exponential distribution and the Weibull distribution. The results of our analysis are specific equations giving information about the characteristics of the power plants, the mean time of operations and the probability of failure-free operation. Equations solved for the Weibull distribution respect the failures as well as the actual operating hours. Thanks to our results, we are able to create a model of dynamic reliability for prediction of future states. It can be useful for improving the current situation of the unit as well as for creating the optimal plan of maintenance and thus have an impact on the overall economics of the operation of these power plants.

  18. Benchmarking Nuclear Power Plants

    International Nuclear Information System (INIS)

    Jakic, I.

    2016-01-01

    One of the main tasks an owner have is to keep its business competitive on the market while delivering its product. Being owner of nuclear power plant bear the same (or even more complex and stern) responsibility due to safety risks and costs. In the past, nuclear power plant managements could (partly) ignore profit or it was simply expected and to some degree assured through the various regulatory processes governing electricity rate design. It is obvious now that, with the deregulation, utility privatization and competitive electricity market, key measure of success used at nuclear power plants must include traditional metrics of successful business (return on investment, earnings and revenue generation) as well as those of plant performance, safety and reliability. In order to analyze business performance of (specific) nuclear power plant, benchmarking, as one of the well-established concept and usual method was used. Domain was conservatively designed, with well-adjusted framework, but results have still limited application due to many differences, gaps and uncertainties. (author).

  19. Wind power plant

    Energy Technology Data Exchange (ETDEWEB)

    Kling, A

    1977-01-13

    The wind power plant described has at least one rotor which is coupled to an electricity generator. The systems are fixed to a suspended body so that it is possible to set up the wind power plant at greater height where one can expect stronger and more uniform winds. The anchoring on the ground or on a floating body is done by mooring cables which can simultaneously have the function of an electric cable. The whole system can be steered by fins. The rotor system itself consists of at least one pair of contrarotating, momentum balanced rotors.

  20. Ardennes nuclear power plant

    International Nuclear Information System (INIS)

    1974-12-01

    The SENA nuclear power plant continued to operate, as before, at authorized rated power, namely 905MWth during the first half year and 950MWth during the second half year. Net energy production:2028GWh; hours phased to the line: 7534H; availability factor: 84%; utilization factor: 84%; total shutdowns:19; number of scrams:10; cost per KWh: 4,35 French centimes. Overall, the plant is performing very satisfactory. Over the last three years net production has been 5900GWh, corresponding to in average utilization factor of 83%

  1. Nuclear power plant

    International Nuclear Information System (INIS)

    Orlov, V.V.; Rineisky, A.A.

    1975-01-01

    The invention is aimed at designing a nuclear power plant with a heat transfer system which permits an accelerated fuel regeneration maintaining relatively high initial steam values and efficiency of the steam power circuit. In case of a plant with three circuits the secondary cooling circuit includes a steam generator with preheater, evaporator, steam superheater and intermediate steam superheater. At the heat supply side the latter is connected with its inlet to the outlet of the evaporator and with its outlet to the low-temperature side of the secondary circuit

  2. TAPCHAN Wave Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    1983-10-01

    The Tapered Channel Wave Power Plant (TAPCHAN) is based on a new method for wave energy conversion. The principle of operation can be explained by dividing the system into the following four sub-systems: Firstly, a collector which is designed to concentrate the water energy and optimize collection efficiency for a range of frequencies and directions. Secondly, the energy converter, in which the energy of the collected waves is transformed into potential energy in an on-shore water reservoir. This is the unique part of the power plant. It consists of a gradually narrowing channel with wall heights equal to the filling level of the reservoir (typical heights 3-7 m). The waves enter the wide end of the channel and as they propagate down the narrowing channel, the wave height is amplified until the wavecrests spill over the walls. Thirdly, a reservoir which provides a stable water supply for the turbines. Finally, the hydroelectric power plant, where well established techniques are used for the generation of electric power. The water turbine driving the electric generator is of a low head type, such as a Kaplan or a tubular turbine. It must be designed for salt water operation and should have good regulation capabilities. Power plants based on the principle described, are now offered on a commercial basis.

  3. Impacts on power generation

    International Nuclear Information System (INIS)

    Myers, J.; Sidebotton, P.

    1998-01-01

    The future impact of the arrival of natural gas in the Maritime provinces on electricity generation in the region was discussed. Currently, electrical generation sources in Nova Scotia include hydro generation (9 per cent), coal generation (80 per cent), heavy fuel oil generation (8 per cent), and light oil, wood chips and purchased power (3 per cent). It is expected that with the introduction of natural gas electric utilities will take advantage of new gas combustion turbines which have high efficiency rates. An overview of Westcoast Power's operations across Canada was also presented. The Company has three projects in the Maritimes - the Courtney Bay project in New Brunswick, the Bayside Power project, the Irving Paper project - in addition to the McMahon cogeneration plant in Taylor, B.C. figs

  4. Impact of the great east Japan earthquake, tsunami, nuclear power plant accident

    International Nuclear Information System (INIS)

    Hosoya, Mitsuaki

    2013-01-01

    The title subject is described mainly from the pediatric aspect. Shortly after the Quake (Mar. 11, 2011), Disaster Medical Assistance Team (DMAT) and Japan Medical Association Team (JMAT) started on their disaster emergent activity with various personnel and students of Fukushima Medical University (FMU). The Power Plant Accident broke out on the next day, and FMU was the base in charge of multiple managements of radiological medicare as well as the ordinary emergent one. Number of children emergently admitted in or requiring the general pediatric consultation was rather small, and problems of insufficient pediatric articles were virtually solved within 2 weeks. Pediatric support by FMU was done from April to May end for children in evacuation places. At 3 months after the disaster, the birth number markedly decreased near the Plant, and pediatric in- and out-patient number also diminished in the whole Fukushima prefecture, suggesting that many at pregnancy or having infants had evacuated out of the prefecture probably because of their concern of possible radiation health hazard. In consideration of epidemiology of A-bomb survivors and of victims in Chernobyl Accident, so much increased prevalence of pediatric thyroid cancer is conceived to be hardly observed after Fukushima Accident. The project of Fukushima Health Management Survey involves fundamental and detailed examinations. The former subject is to all of prefectural residents who lived at the time of the Quake and the latter, to all children's thyroid with the age <18 y by ultrasonographic follow-up, to all residents dwelled in the evacuation areas by the detailed physical and mental/life-style examinations and to pregnant women by questionnaire and follow-up. Residents' concern is mostly toward the health of infants who are sensitive to radiation. (T.T.)

  5. Geothermal Power Generation Plant

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya [Oregon Inst. of Technology, Klamath Falls, OR (United States). Geo-Heat Center

    2013-12-01

    Oregon Institute of Technology (OIT) drilled a deep geothermal well on campus (to 5,300 feet deep) which produced 196°F resource as part of the 2008 OIT Congressionally Directed Project. OIT will construct a geothermal power plant (estimated at 1.75 MWe gross output). The plant would provide 50 to 75 percent of the electricity demand on campus. Technical support for construction and operations will be provided by OIT’s Geo-Heat Center. The power plant will be housed adjacent to the existing heat exchange building on the south east corner of campus near the existing geothermal production wells used for heating campus. Cooling water will be supplied from the nearby cold water wells to a cooling tower or air cooling may be used, depending upon the type of plant selected. Using the flow obtained from the deep well, not only can energy be generated from the power plant, but the “waste” water will also be used to supplement space heating on campus. A pipeline will be construction from the well to the heat exchanger building, and then a discharge line will be construction around the east and north side of campus for anticipated use of the “waste” water by facilities in an adjacent sustainable energy park. An injection well will need to be drilled to handle the flow, as the campus existing injection wells are limited in capacity.

  6. Comparative study of radiological assessment impact of nuclear power plant and coal-fired power plant: the atmospheric dispersion factor (χ/Q) in Muria Peninsula, Jepara

    International Nuclear Information System (INIS)

    Umbara, H.; Syahrir; Yatim, S.

    1997-01-01

    The atmospheric dispersion factor (χ/Q) in Muria Peninsula, Jepara was carried out to calculate the exposure dose to public from nuclear power plant and coal-fired plant. The dispersion factor (χ/Q) value was calculated with mathematical model and diffusion equation. Parameter used as the input data was taken from meteorological data of Ujung Watu site within one year (August 1994 - July 1995) to obtain joint frequency distribution data which were the percentage of wind speed and stability class for 16 sector within one year. The results indicated that the highest dispersion factor (χ/Q) within 300 - 700 m radius from point of release is 4.750E-07 - 8.238E-07 second/m 3 for north west direction (author)

  7. Nuclear power plant analyzer

    International Nuclear Information System (INIS)

    Stritar, A.

    1986-01-01

    The development of Nuclear Power Plant Analyzers in USA is described. There are two different types of Analyzers under development in USA, the forst in Idaho and Los Alamos national Lab, the second in brookhaven National lab. That one is described in detail. The computer hardware and the mathematical models of the reactor vessel thermalhydraulics are described. (author)

  8. Nuclear power plant

    International Nuclear Information System (INIS)

    Wieser, R.

    1979-01-01

    The reactor pressure vessel consists of two parts. A cylindrical lower part with a hemispherical steel roof is placed at some distance within an equally shaped pressure vessel of concrete. Both vessels are standing on a common bottom plate. The interspace is kept at subpressure. It serves to contain ring galleries, elevator shafts, and power plant components. (GL) [de

  9. Nuclear Power Plant Technician

    Science.gov (United States)

    Randall, George A.

    1975-01-01

    The author recognizes a body of basic knowledge in nuclear power plant technoogy that can be taught in school programs, and lists the various courses, aiming to fill the anticipated need for nuclear-trained manpower--persons holding an associate degree in engineering technology. (Author/BP)

  10. Steam power plant

    International Nuclear Information System (INIS)

    Campbell, J.W.E.

    1981-01-01

    This invention relates to power plant forced flow boilers operating with water letdown. The letdown water is arranged to deliver heat to partly expanded steam passing through a steam reheater connected between two stages of the prime mover. (U.K.)

  11. Power plants 2009. Lectures

    International Nuclear Information System (INIS)

    2009-01-01

    Within the Annual Conference 2009 of the VGB PowerTech e.V. (Essen, Federal Republic of Germany) from 23rd to 25th May, 2009, in Lyon (France) the following lectures were held: (1) Electricity demand, consequences of the financial and economic crisis - Current overview 2020 for the EU-27 (Hans ten Berge); (2) Status and perspectives of the electricity generation mix in France (Bernard Dupraz); (3) European electricity grid - status and perspective (Dominique Maillard); (4) Technologies and acceptance in the European energy market (Gordon MacKerran); (5) EPR construction in Finland, China, France, (Claude Jaouen); (6) EPR Flamanville 3: A project on the path towards nuclear revival (Jacques Alary); (7) Worldwide nuclear Revival and acceptance (Luc Geraets); (8) An overview on the status of final disposal of radioactive wastes worldwide (Piet Zuidema); (9) Who needs pumped storage plants? PSP are partner to grid stability and renewable energies (Hans-Christoph Funke); (10) Sustainable use of water resources to generate electricity safely and efficiently (Patrick Tourasse); (11) The growth strategy of RWE Innogy - Role of RES in RWE strategy (Fritz Vahrenholt); (12) Solar technologies towards grid parity - key factors and timeframe (G. Gigliucci); (13) Overview on CCS technologies and results of Vattenfalls oxyfuel pilot plant (Philippe Paelinck); (14) Development perspectives of lignite-based IGCC-plants with CCS (Dietmar Keller); (15) Post combustion capture plants - concept and plant integration (Wolfgang Schreier); (16) CCS fossil power generation in a carbon constraint world (Daniel Hofmann); (17) CEZ group strategy in Central and South Eastern Europe (Jan Zizka); (18) Strategy and projects of DONG Energy (Jens Erik Pedersen); (19) E.ON coal-based power generation of the future - The highly efficient power plant and downstream separation of carbon dioxide (Gerhard Seibel); (20) Final sage of first supercritical 460 MW e l. CFB Boiler construction - firs

  12. Impact of steam generator start-up limitations on the performance of a parabolic trough solar power plant

    DEFF Research Database (Denmark)

    Ferruzza, Davide; Topel, Monika; Laumert, Björn

    2018-01-01

    typically start-up and shut down every day, so in order to maximize their profitability, it is necessary to increase their flexibility in transient operation and to initiate power generation as rapidly as possible. Two of the key components are the steam generator and steam turbine and the rates at which...... they can reach operational speed are limited by thermo-mechanical constraints. This paper presents an analysis of the effects of the thermal stress limitations of the steam generator and steam turbine on the power plant start-up, and quantifies their impact on the economy of the system. A dynamic model......-driven and peak-load. The results indicate that for steam generator hot start-ups, a 1.5% increase in peak-load electricity production would be achieved by doubling the maximum allowable heating rate of the evaporator. No useful increase would be achieved by increasing the rates beyond a limit of 7–8 K...

  13. Inductive analysis of failure patterns and of their impact on thermohydraulic circuits of nuclear power plants

    International Nuclear Information System (INIS)

    Limnios, N.

    1983-01-01

    The APACHE code (Automatic Analysis of Failures of Hydraulic and Thermohydraulic Circuits more particularly of Water) situates in an important program of computer codes development in the field of studies on reliability and safety of systems in nuclear power plants. APACHE is an automatic generation code of failure pattern and of their effects. After a presentation of the theoretical basis, the methodological principles of the theory of networks are developed. Then, the model of the code is developed: model of individual behavior of each classical model component of normal behavior and model of failure pattern with specifications. The global model of hydraulic systems and the resolution systems are then developed. More particularly, some aspects of the theory of graphs, and the algorithms developed for the automatic construction of the equation systems and especially the algorithm of the research of meshes are presented. The computer aspect of the code and the programming of the code with its limits and some specifications are described. The practical aspect of utilization is finally presented [fr

  14. Radioactive contamination of fishes in lake and streams impacted by the Fukushima nuclear power plant accident

    International Nuclear Information System (INIS)

    Yoshimura, Mayumi; Yokoduka, Tetsuya

    2014-01-01

    The Fukushima Daiichi Nuclear Power Plant (FDNPP) accident in March 2011 emitted radioactive substances into the environment, contaminating a wide array of organisms including fishes. We found higher concentrations of radioactive cesium ( 137 Cs) in brown trout (Salmo trutta) than in rainbow trout (Oncorhynchus nerka), and 137 Cs concentrations in brown trout were higher in a lake than in a stream. Our analyses indicated that these differences were primarily due to differences in diet, but that habitat also had an effect. Radiocesium concentrations ( 137 Cs) in stream charr (Salvelinus leucomaenis) were higher in regions with more concentrated aerial activity and in older fish. These results were also attributed to dietary and habitat differences. Preserving uncontaminated areas by remediating soils and releasing uncontaminated fish would help restore this popular fishing area but would require a significant effort, followed by a waiting period to allow activity concentrations to fall below the threshold limits for consumption. - Highlight: • Concentration of 137 Cs in brown trout was higher than in rainbow trout. • 137 Cs concentration of brown trout in a lake was higher than in a stream. • 137 Cs concentration of stream charr was higher in region with higher aerial activity. • Concentration of 137 Cs in stream charr was higher in older fish. • Difference of contamination among fishes was due to difference in diet and habitat

  15. Radioactive contamination of fishes in lake and streams impacted by the Fukushima nuclear power plant accident

    Energy Technology Data Exchange (ETDEWEB)

    Yoshimura, Mayumi, E-mail: yoshi887@ffpri.affrc.go.jp [Kansai Research Center, Forestry and Forest Products Research Institute, Nagaikyuutaro 68, Momoyama, Fushimi, Kyoto 612-0855 (Japan); Yokoduka, Tetsuya [Tochigi Prefectural Fisheries Experimental Station, Sarado 2599, Ohtawara, Tochigi 324-0404 (Japan)

    2014-06-01

    The Fukushima Daiichi Nuclear Power Plant (FDNPP) accident in March 2011 emitted radioactive substances into the environment, contaminating a wide array of organisms including fishes. We found higher concentrations of radioactive cesium ({sup 137}Cs) in brown trout (Salmo trutta) than in rainbow trout (Oncorhynchus nerka), and {sup 137}Cs concentrations in brown trout were higher in a lake than in a stream. Our analyses indicated that these differences were primarily due to differences in diet, but that habitat also had an effect. Radiocesium concentrations ({sup 137}Cs) in stream charr (Salvelinus leucomaenis) were higher in regions with more concentrated aerial activity and in older fish. These results were also attributed to dietary and habitat differences. Preserving uncontaminated areas by remediating soils and releasing uncontaminated fish would help restore this popular fishing area but would require a significant effort, followed by a waiting period to allow activity concentrations to fall below the threshold limits for consumption. - Highlight: • Concentration of {sup 137}Cs in brown trout was higher than in rainbow trout. • {sup 137}Cs concentration of brown trout in a lake was higher than in a stream. • {sup 137}Cs concentration of stream charr was higher in region with higher aerial activity. • Concentration of {sup 137}Cs in stream charr was higher in older fish. • Difference of contamination among fishes was due to difference in diet and habitat.

  16. Environmental impact from wet plumes in combined-cycle power plants

    International Nuclear Information System (INIS)

    Corti, A.; Carnevale, E.

    1998-01-01

    In the present study, we have carried out an investigation into some of the environmental effects of high energy efficiency power generation plants that produce electrical and thermal energy. The use of natural gas fuels may represent a success for the replacement of liquid or solid fuels, because of drastic reductions of sulphur oxides, carbon dioxide and particulates. An additional problem involves the study of the effects of vapour emissions from the combustion of fuels and from the cooling towers of the condenser device. Particularly, the problem of the analysis of vapour and drift diffusion, because of emissions from the wet cooling devices, is faced in terms of modelling the plume rise and mass loss of drift in the atmosphere, because of evaporation, in order to predict the increment of rain and the humidity effect. The results obtained show that the amount of water emitted in the forms of vapour and drift, in terms of local scale diffusion, do not create problems of high increments of relative humidity or dangerous rainfall phenomena; while the effects of vapour emission are shown as insignificant problems because of the deposition of a sensible amount of drift, correlated with the type of of separator devices chosen can appear, but only on very limited areas. (author)

  17. The impact of safety standards updating for design purposes in nuclear power plants licensing

    International Nuclear Information System (INIS)

    Alvarenga, Marco Antonio Bayout; Rabello, Sidney Luiz

    2009-01-01

    The Brazilian experience of nuclear power plants licensing was consolidated by the use of the Brazilian, American, German and IAEA standards. Independently of the set of norms, standards or guides to be used, this set should be in consonance with the state-of-art or the current state of knowledge in science and technology. In the general design criteria of US NRC or German BMI, or in the Brazilian norms (CNEN) or even, in the IAEA standards, this aspect is always emphasized. On the other hand, the international operational experience of nuclear reactors (for example, TMI accident) also contributes to the updating of norms and standards. The use of new technologies (for example, digital technology) impels the norms and standards to adopt new design criteria related to the new technological context. Moreover, we must add the particular vision that each country can have concerning to specific topics in nuclear safety. This work discusses how the norms, standards and guides used in the nuclear licensing are being reviewed to cope with the requirement of the state-of-art. In order to accomplish this aim we took some general design criteria to exemplify how they are fulfilled, mainly those related directly with the protection of the defense-in-depth barriers: primary coolant system, containment vessel and containment systems, including external events and severe accidents. In complement to the deterministic analysis, it is also discussed the design criteria related to the human factors engineering and probabilistic safety analysis, including severe accidents aspects. (author)

  18. Beloyarsk Nuclear Power Plant

    International Nuclear Information System (INIS)

    1997-01-01

    The Beloyarsk Nuclear Power Plant (BNPP) is located in Zarechny, approximately 60 km east of Ekaterinberg along the Trans-Siberian Highway. Zarechny, a small city of approximately 30,000 residents, was built to support BNPP operations. It is a closed city to unescorted visitors. Residents must show identification for entry. BNPP is one of the first and oldest commercial nuclear power plants in Russia and began operations in 1964. As for most nuclear power plants in the Russian Federation, BNPP is operated by Rosenergoatom, which is subordinated to the Ministry of Atomic Energy of the Russian Federation (Minatom). BNPP is the site of three nuclear reactors, Units 1, 2, and 3. Units 1 and 2, which have been shut-down and defueled, were graphite moderated reactors. The units were shut-down in 1981 and 1989. Unit 3, a BN-600 reactor, is a 600 MW(electric) sodium-cooled fast breeder reactor. Unit 3 went on-line in April 1980 and produces electric power which is fed into a distribution grid and thermal power which provides heat to Zarechny. The paper also discusses the SF NIKIET, the Sverdiovsk Branch of NIKIET, Moscow, which is the research and development branch of the parent NIKEIT and is primarily a design institute responsible for reactor design. Central to its operations is a 15 megawatt IVV research reactor. The paper discusses general security and fissile material control and accountability at these two facilities

  19. Nuclear power plant safety

    International Nuclear Information System (INIS)

    Otway, H.J.

    1974-01-01

    Action at the international level will assume greater importance as the number of nuclear power plants increases, especially in the more densely populated parts of the world. Predictions of growth made prior to October 1973 [9] indicated that, by 1980, 14% of the electricity would be supplied by nuclear plants and by the year 2000 this figure would be about 50%. This will make the topic of international co-operation and standards of even greater importance. The IAEA has long been active in providing assistance to Member States in the siting design and operation of nuclear reactors. These activities have been pursued through advisory missions, the publication of codes of practice, guide books, technical reports and in arranging meetings to promote information exchange. During the early development of nuclear power, there was no well-established body of experience which would allow formulation of internationally acceptable safety criteria, except in a few special cases. Hence, nuclear power plant safety and reliability matters often received an ad hoc approach which necessarily entailed a lack of consistency in the criteria used and in the levels of safety required. It is clear that the continuation of an ad hoc approach to safety will prove inadequate in the context of a world-wide nuclear power industry, and the international trade which this implies. As in several other fields, the establishment of internationally acceptable safety standards and appropriate guides for use by regulatory bodies, utilities, designers and constructors, is becoming a necessity. The IAEA is presently planning the development of a comprehensive set of basic requirements for nuclear power plant safety, and the associated reliability requirements, which would be internationally acceptable, and could serve as a standard frame of reference for nuclear plant safety and reliability analyses

  20. Latina nuclear power plant

    International Nuclear Information System (INIS)

    1976-03-01

    In the period under review, the Latina power plant produced 1009,07 million kWh with a utilization factor of 72% and an availability factor of 80,51%. The disparity between the utilization and availability factors was mainly due to the shutdown of the plant owing to trade union strife. The reasons for non-availability (19,49%) were almost all related to the functioning of the conventional part and the general servicing of the plant (18 September-28 October). During the shutdown for maintenance, an inspection of the steel members and parts of the core stabilizing structure was made in order to check for the familiar oxidation phenomena caused by CO 2 ; the results of the inspection were all satisfactory. Operation of the plant during 1974 was marked by numerous power cutbacks as a result of outages of the steam-raising units (leaks from the manifolds) and main turbines (inspection and repairs to the LP rotors). Since it was first brought into commercial operation, the plant has produced 13,4 thousand million kWh

  1. Impact of proximity of thermoelectric power plants on bronchial obstructive crisis rates

    Directory of Open Access Journals (Sweden)

    Tamara Ugarte-Avilés

    2017-01-01

    Full Text Available Abstract Background Environmental pollution is a risk factor for cardiorespiratory diseases. Energy generated by thermoelectric power plants (TEPP represents a relevant source of pollution. The aim of this study was to evaluate the relationship between living near a coal-fired TEPP and the consultation rates for bronchial obstructive crises (BOC in the province of Concepción, Chile. Methods Population-based study. The epidemiological weeks from 2012 to 2014 were analyzed. The dependent variable was the emergency consultation rate for BOC in two health centers within 5 km of a TEPP (Coronel and two that were more than 40 Km away from a TEPP (Talcahuano. The independent variables were the commune, climatological variables (air temperature and relative atmospheric humidity, environmental pollutants (PM10, PM2.5 and nitrogen oxide, weeks with the highest consultation rate and the years. Rates, Pearson’s correlation and gross risk measures were calculated and adjusted for environmental and climatological variables. Results BOC rates were significantly higher in Coronel (RR = 4.9 95% CI 4.0–5.8; p < 0.05. The PM2.5 it showed the strongest correlation with BOC rates (r = 0.3; p < 0.01 in Coronel, but not Talcahuano. Linear regression modelling indicated that proximity to a TEPP (health center location and temperature explained 26 and 18% of the variance in BOC rates, respectively. Conclusions Rates of emergency consultation for BOC were significantly higher among a population living within 5 km of a coal-fired TEPP than those living 40 km away.

  2. Impact of fuel cell power plants on multi-objective optimal operation management of distribution network

    Energy Technology Data Exchange (ETDEWEB)

    Niknam, T. [Electrical and Electronic Engineering Department, Shiraz University of Technology, Shiraz (Iran, Islamic Republic of); Zeinoddini-Meymand, H. [Islamic Azad University, Kerman Branch, Kerman (Iran, Islamic Republic of)

    2012-06-15

    This paper presents an interactive fuzzy satisfying method based on hybrid modified honey bee mating optimization and differential evolution (MHBMO-DE) to solve the multi-objective optimal operation management (MOOM) problem, which can be affected by fuel cell power plants (FCPPs). The objective functions are to minimize total electrical energy losses, total electrical energy cost, total pollutant emission produced by sources, and deviation of bus voltages. A new interactive fuzzy satisfying method is presented to solve the multi-objective problem by assuming that the decision-maker (DM) has fuzzy goals for each of the objective functions. Through the interaction with the DM, the fuzzy goals of the DM are quantified by eliciting the corresponding membership functions. Then, by considering the current solution, the DM acts on this solution by updating the reference membership values until the satisfying solution for the DM can be obtained. The MOOM problem is modeled as a mixed integer nonlinear programming problem. Evolutionary methods are used to solve this problem because of their independence from type of the objective function and constraints. Recently researchers have presented a new evolutionary method called honey bee mating optimization (HBMO) algorithm. Original HBMO often converges to local optima, in order to overcome this shortcoming, we propose a new method that improves the mating process and also, combines the modified HBMO with DE algorithm. Numerical results for a distribution test system have been presented to illustrate the performance and applicability of the proposed method. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  3. AND THERMAL POWER PLANTS

    Directory of Open Access Journals (Sweden)

    Alduhov Oleg Aleksandrovich

    2012-10-01

    Full Text Available Investigation of the atmospheric dispersion as part of the process of selection of sites to accommodate nuclear and thermal power plants is performed to identify concentration fields of emissions and to assess the anthropogenic impact produced on the landscape components and human beings. Scattering properties of the atmospheric boundary layer are mainly determined by the turbulence intensity and the wind field. In its turn, the turbulence intensity is associated with the thermal stratification of the boundary layer. Therefore, research of the atmospheric dispersion is reduced to the study of temperature and wind patterns of the boundary layer. Statistical processing and analysis of the upper-air data involves the input of the data collected by upper-air stations. Until recently, the upper-air data covering the standard period between 1961 and 1970 were applied for these purposes, although these data cannot assure sufficient reliability of assessments in terms of the properties of the atmospheric dispersion. However, recent scientific and technological developments make it possible to substantially increase the data coverage by adding the upper-air data collected within the period between 1964 and 2010. The article has a brief overview of BL_PROGS, a specialized software package designated for the processing of the above data. The software package analyzes the principal properties of the atmospheric dispersion. The use of the proposed software package requires preliminary development of a database that has the information collected by an upper-air station. The software package is noteworthy for the absence of any substantial limitations imposed onto the amount of the input data that may go up in proportion to the amount of the upper-air data collected by upper-air stations.

  4. Science, law, and Hudson River power plants: A case study in environmental impact assessment

    International Nuclear Information System (INIS)

    Barnthouse, L.W.; Klauda, R.J.; Vaughan, D.S.; Kendall, R.L.

    1988-01-01

    Between 1963 and 1980, the Hudson River estuary was the focus of one of the most ambitious environmental research and assessment programs ever performed. The studies supported a series of US federal proceedings involving licenses and discharge permits for two controversial electric power generating facilities: the Cornwall pumped storage facility, and units 2 and 3 of the Indian Point nuclear generating station. Both facilities were to draw large volumes of water from a region of the Hudson used as spawning and nursery habitat by several fish species, including the striped bass. Fishermen and conservationists feared that a major fraction of the striped bass eggs and larvae in the Hudson would be entrained with the pumped water and killed. Additional fish would be killed on trash screens at the intakes. Scientists were asked to aid the utility companies and regulatory agencies in determining the biological importance of entrainment and impingement. This monograph contains both technical papers that present research results and synthesis papers that summarize and interpret the results. The intent was to: (1) summarize the scientific issues and approaches; (2) present the significant results of the Hudson River biological studies; (3) describe the role of the studies in the decision-making process; (4) evaluate the successes and failures of the studies; and (5) present recommendations for future estuarine impact assessments. Separate abstracts are processed for 22 papers for inclusion in the appropriate data bases

  5. Integrated safety assessment of Indian nuclear power plants for extreme events: reducing impact on public mind

    International Nuclear Information System (INIS)

    Kakodkar, Anil; Singh, Ram Kumar

    2013-01-01

    Nuclear energy professionals need to understand and address the catastrophe syndrome that of late seems to be increasingly at work in public mind in the context of nuclear energy. Classically the nuclear power reactor design and system evolution has been based on the logic of minimization of risk to an acceptable level and its quantification based on a deterministic approach and backed up by a further assessment based on the probabilistic methodology. However, in spite of minimization of risk, the reasons for anxiety and trauma in public mind that still prevails in the context of severe accidents needs to be understood and addressed. Margins between maximum credible accidents factored in the design and the ultimate load withstanding capacities of relevant systems need to be enhanced and guaranteed with a view to minimize release of radioactivity and avoid serious impact in public domain. A more realistic basis for management of an accident in public domain also needs to be quantified for this purpose. Assurance to public on limiting the consequences to a level that does not lead to a trauma is something that we need to be able to credibly demonstrate and confirm. The findings from Chernobyl reports point to significant psychological effects and related health disorders due to large scale emergency relocation of people that could have been possibly reduced by an order of magnitude without significant additional safety detriment

  6. Wind power plant

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, G

    1975-11-20

    A wind power plant is proposed suitable for electicity generation or water pumping. This plant is to be self-adjusting to various wind velocities and to be kept in operation even during violent storms. For this purpose the mast, carrying the wind rotor and pivotable around a horizontal axis is tiltable and equipped with a wind blind. Further claims contain various configurations of the tilting base resp. the cut in of an elastic link, the attachment and design of the wind blind as well as the constructive arrangement of one or more dynamos.

  7. Power plant process computer

    International Nuclear Information System (INIS)

    Koch, R.

    1982-01-01

    The concept of instrumentation and control in nuclear power plants incorporates the use of process computers for tasks which are on-line in respect to real-time requirements but not closed-loop in respect to closed-loop control. The general scope of tasks is: - alarm annunciation on CRT's - data logging - data recording for post trip reviews and plant behaviour analysis - nuclear data computation - graphic displays. Process computers are used additionally for dedicated tasks such as the aeroball measuring system, the turbine stress evaluator. Further applications are personal dose supervision and access monitoring. (orig.)

  8. Fossil power plant automation

    International Nuclear Information System (INIS)

    Divakaruni, S.M.; Touchton, G.

    1991-01-01

    This paper elaborates on issues facing the utilities industry and seeks to address how new computer-based control and automation technologies resulting from recent microprocessor evolution, can improve fossil plant operations and maintenance. This in turn can assist utilities to emerge stronger from the challenges ahead. Many presentations at the first ISA/EPRI co-sponsored conference are targeted towards improving the use of computer and control systems in the fossil and nuclear power plants and we believe this to be the right forum to share our ideas

  9. Impact of advanced wind power ancillary services on power system

    DEFF Research Database (Denmark)

    Hansen, Anca Daniela; Altin, Müfit

    The objective of this report is to illustrate and analyse, by means of simulation test cases, the impact of wind power advanced ancillary services, like inertial response (IR), power oscillation damping (POD) and synchronising power (SP) on the power system. Generic models for wind turbine, wind...... power plant and power system are used in the investigation....

  10. Virtual power plant auctions

    International Nuclear Information System (INIS)

    Ausubel, Lawrence M.; Cramton, Peter

    2010-01-01

    Since their advent in 2001, virtual power plant (VPP) auctions have been implemented widely. In this paper, we describe the simultaneous ascending-clock auction format that has been used for virtually all VPP auctions to date, elaborating on other design choices that most VPP auctions have had in common as well as discussing a few aspects that have varied significantly among VPP auctions. We then evaluate the various objectives of regulators in requiring VPP auctions, concluding that the auctions have been effective devices for facilitating new entry into electricity markets and for developing wholesale power markets. (author)

  11. Virtual power plant auctions

    Energy Technology Data Exchange (ETDEWEB)

    Ausubel, Lawrence M.; Cramton, Peter [Department of Economics, University of Maryland, College Park, MD 20742 (United States)

    2010-12-15

    Since their advent in 2001, virtual power plant (VPP) auctions have been implemented widely. In this paper, we describe the simultaneous ascending-clock auction format that has been used for virtually all VPP auctions to date, elaborating on other design choices that most VPP auctions have had in common as well as discussing a few aspects that have varied significantly among VPP auctions. We then evaluate the various objectives of regulators in requiring VPP auctions, concluding that the auctions have been effective devices for facilitating new entry into electricity markets and for developing wholesale power markets. (author)

  12. Application of fisheries management techniques to assessing impacts: task I report. [Assessment of chemical, radiological, and thermal impacts of nuclear power plants on fish populations

    Energy Technology Data Exchange (ETDEWEB)

    McKenzie, D.H.; Baker, K.S.; Fickeisen, D.H.; Metzger, R.M.; Skalski, J.R.

    1979-03-01

    Task I efforts examined the available fisheries management techniques and assessed their potential application in a confirmatory monitoring program. The objective of such monitoring programs is to confirm that the prediction of an insignificant impact (usually made in the FES) was correct. Fisheries resource managers have developed several tools for assessing the fish population response to stress (exploitation) and they were thought potentially useful for detecting nuclear power plant impacts. Techniques in three categories were examined; catch removal, population dynamics, and nondestructive censuses, and the report contains their description, examples of application, advantages, and disadvantages. The techniques applied at nuclear power plant sites were examined in detail to provide information on implementation and variability of specific approaches. The most suitable techniques to incorporate into a monitoring program confirming no impact appear to be those based on Catch Per Unity Effort (CPUE) and hydroacoustic data. In some specific cases, age and growth studies and indirect census techniques may be beneficial. Recommendations for task II efforts to incorporate these techniques into monitoring program designs are presented. These include development of guidelines for; (1) designing and implementing a data collection program; (2) interpreting these data and assessing the occurrence of impact, and (3) establishment of the monitoring program's ability to detect changes in the affected populations.

  13. Carbon Emission Impact for Energy Strategy in which All Non-CSS Coal Power Plants Are Replaced by Nuclear Power Plants

    International Nuclear Information System (INIS)

    Knapp, V.; Matijevic, M.; Pevec, D.; Lale, D.

    2016-01-01

    The Paris climate conference recognized the urgency of measures to mitigate climate changes and achieved an agreement on the targets for future decades. We wish to show that advanced LWR initiated nuclear strategy can offer us long term carbon free energy future. Human action is putting carbon dioxide into atmosphere where it resides effectively for hundreds of years. We are forced to look ahead on the same time scale but we have much shorter time to act as we almost used up the quota of emission of carbon before disaster would be unavoidable, as shown in paper by Meinshausen et al. and IPCC report. We have to change our ways of relying on fossil fuel dramatically in the next few decades. It would be a change in use of fossil fuel which cannot be achieved with usual business practices. Arising awareness of reality and threat of global warming in parallel with fading promise of nuclear fusion and Carbon Capture and Storage (CCS) technology, should convince the public to accept nuclear fission contribution to climate change mitigation, at least for the climate critical years up to 2065. Nuclear fission has the additional value of supporting intermittent sources by covering the base load consumption. It can be available now, with proven reactors, such as advanced LWR reactors. Nuclear strategy in this paper outlines a proposal to replace all non-CCS coal power plants with nuclear power plants in the period 2025-2065. Assuming once through advanced LWR technology, one would need nuclear capacity of 1600 GW to replace coal power plants in the period 2025-2065. Corresponding reduction of emission would amount to 11.8 Gt of CO2. This energy strategy would reduce carbon emission by approximately 22 percent in the year 2065. The annual uranium requirements and the cumulative uranium requirements, as well as the annual plutonium production and cumulative plutonium production for the proposed nuclear strategy are determined. A possibility of larger reduction of carbon

  14. Nuclear power plant

    International Nuclear Information System (INIS)

    Aisaka, Tatsuyoshi; Kamahara, Hisato; Yanagisawa, Ko.

    1982-01-01

    Purpose: To prevent corrosion stress cracks in structural materials in a BWR type nuclear power plant by decreasing the oxygen concentration in the reactor coolants. Constitution: A hydrogen injector is connected between the condensator and a condensate clean up system of a nuclear power plant. The injector is incorporated with hydrogenated compounds formed from metal hydrides, for example, of alloys such as lanthanum-nickel alloy, iron titanium alloy, vanadium, palladium, magnesium-copper alloy, magnesium-nickel alloy and the like. Even if the pressure of hydrogen obtained from a hydrogen bomb or by way of water electrolysis is changed, the hydrogen can always be injected into a reactor coolant at a pressure equal to the equilibrium dissociation pressure for metal hydride by introducing the hydrogen into the hydrogen injector. (Seki, T.)

  15. Ageing of power plants socio-economical, sanitary and environmental impact; Veillissement des centrales Impacts socio-economiques, sanitaires et environnementaux

    Energy Technology Data Exchange (ETDEWEB)

    Bataille, Ch. [Depute du nord (France); Denner, M. [EDF pour la Region Bourgogne (France); Vouilloux, F. [Institut de Radioprotection et de Surete Nucleaire, 92 - Fontenay-aux-Roses (France); Foucher, L. [Direction Generale de la Surete Nucleaire et de la Radioprotection, 75 - Paris (France); Serviere, M. [Electricite de France (EDF), 75 - Paris (France); Vila d' Abadal Serra, M

    2005-07-01

    The National Association of the local Commissions of Information (A.N.C.L.I.) presents a colloquium about the ageing of nuclear power plants. The different following points are presented. The life cycle of nuclear power plants and the new types of reactors. The ageing of power plants: stakes and perspectives for the French and world nuclear park. A power plant of 30 years is it sure? The role of the studies of ageing and the follow-up according to the age. Stop or continue to exploit a nuclear power plant: who decides, when and how. The socio-economic consequences of a stop of power plant: the Spanish experience. Ten-year visits of a power plant: the associative experience. 58 reactors today: how to assume their end of life and welcome equipments to come. (N.C.)

  16. Nuclear power plant

    International Nuclear Information System (INIS)

    Schabert, H.P.; Laurer, E.

    1976-01-01

    The invention concerns a quick-acting valve on the main-steam pipe of a nuclear power plant. The engineering design of the valve is to be improved. To the main valve disc, a piston-operated auxiliary valve disc is to be assigned closing a section of the area of the main valve disc. This way it is avoided that the drive of the main valve disc has to carry out different movements. 15 sub-claims. (UWI) [de

  17. Fusion power plant economics

    International Nuclear Information System (INIS)

    Miller, R.L.

    1996-01-01

    The rationale, methodology, and updated comparative results of cost projections for magnetic-fusion-energy central-station electric power plants are considered. Changing market and regulatory conditions, particularly in the U.S., prompt fundamental reconsideration of what constitutes a competitive future energy-source technology and has implications for the direction and emphasis of appropriate near-term research and development programs, for fusion and other advanced generation systems. 36 refs., 2 figs., 2 tabs

  18. Power plant emissions reduction

    Science.gov (United States)

    Anand, Ashok Kumar; Nagarjuna Reddy, Thirumala Reddy

    2015-10-20

    A system for improved emissions performance of a power plant generally includes an exhaust gas recirculation system having an exhaust gas compressor disposed downstream from the combustor, a condensation collection system at least partially disposed upstream from the exhaust gas compressor, and a mixing chamber in fluid communication with the exhaust gas compressor and the condensation collection system, where the mixing chamber is in fluid communication with the combustor.

  19. Estimation of environmental external costs between coal fired power plant and nuclear power plant

    International Nuclear Information System (INIS)

    Moon, G. H.; Kim, S. S.

    2000-01-01

    First of all, this study evaluated the impacts on the health and the environment of air pollutants emitted from coal power plant and nuclear power pant, two major electric power generating options in Korea. Then, the environmental external costs of those two options were estimated by transforming the health and environment impact into monetary values. To do this, AIRPACTS and Impacts of Atmospheric Release model developed by IAEA were used. The environmental external cost of Samcheonpo coal power plant was estimated about 25 times as much as that of Younggwang nuclear power plant. This result implies that nuclear power plant is a clean technology compared with coal power plant. This study suggests that the external cost should be reflected in the electric system expansion plan in order to allocate energy resources efficiently and to reduce economic impact stemming from the environmental regulation emerged recently on a global level

  20. Atomic power plant

    International Nuclear Information System (INIS)

    Kawakami, Hiroto.

    1975-01-01

    Object: To permit decay heat to be reliably removed after reactor shut-down at such instance as occurrence of loss of power by means of an emergency water supply pump. Structure: An atomic power plant having a closed cycle constructed by connecting a vapor generator, a vapor valve, a turbine having a generator, a condenser, and a water supply pump in the mentioned order, and provided with an emergency water supply pump operated when there is a loss of power to the water supply pump, a degasifier pressure holding means for holding the pressure of the degasifier by introducing part of the vapor produced from said vapor generator, and a valve for discharge to atmosphere provided on the downstream side of said vapor generator. (Kamimura, M.)

  1. Evaluation of nuclear power plant environmental impact prediction, based on monitoring programs. Summary and recommendations

    International Nuclear Information System (INIS)

    Gore, K.L.; Thomas, J.M.; Kannberg, L.D.; Watson, D.G.

    1977-02-01

    An evaluation of the effectivenss of non-radiological environmental monitoring programs is presented. The monitoring programs for Monticello, Haddam Neck, and Millstone Nuclear Generating Plants are discussed. Recommendations for improvements in monitoring programs are presented

  2. Radioactive airborne effluents and the environmental impact assessment of CAP1400 nuclear power plant under normal operation

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Qiong; Guo, RuiPing; Zhang, ChunMing; Chen, XiaoQiu; Wang, Bo, E-mail: wangbo@chinansc.cn

    2014-12-15

    Highlights: • Typical radionuclides dispersion from CAP1400 under normal operation was simulated. • Modified Gaussian model considered radioactive decay, dry and wet deposition and so on. • The radioactive impact pathways on the public through atmosphere were compared. • The maximum individual effective dose was lower than the public irradiation limit. - Abstract: China Advanced Passive nuclear power plant with installed capacity reaching to 1400 MW (CAP1400) is independently designed as the China's state-of-the-art third generation nuclear power brand based on AP1000 technology digestion and absorption. The concentration of typical radionuclides dispersed from CAP1400 under normal operation was calculated with modified Gaussian model, considering mixed layer height, dry deposition, wet deposition, radioactive decay and so on. The atmospheric dispersion factors, ground deposition rate, individual dose and public dose were also investigated to estimate the radioactive effects of CAP1400 under normal operation on surrounding environment and human beings. The radioactive impact pathways on the public through atmosphere, such as immersion irradiation in the smoke plume, internal irradiation from ingestion and inhalation and external irradiation from surface deposition were briefly introduced with focus on the comparison of the maximum individual effective dose to different group from atmospheric dispersion. All computation results show that the maximum individual irradiation dose happened to children with total effective irradiation dose of 4.52E−03 mSv/y, which was lower than the public irradiation limit of 0.25 mSv/y.

  3. Radioactive airborne effluents and the environmental impact assessment of CAP1400 nuclear power plant under normal operation

    International Nuclear Information System (INIS)

    Zhang, Qiong; Guo, RuiPing; Zhang, ChunMing; Chen, XiaoQiu; Wang, Bo

    2014-01-01

    Highlights: • Typical radionuclides dispersion from CAP1400 under normal operation was simulated. • Modified Gaussian model considered radioactive decay, dry and wet deposition and so on. • The radioactive impact pathways on the public through atmosphere were compared. • The maximum individual effective dose was lower than the public irradiation limit. - Abstract: China Advanced Passive nuclear power plant with installed capacity reaching to 1400 MW (CAP1400) is independently designed as the China's state-of-the-art third generation nuclear power brand based on AP1000 technology digestion and absorption. The concentration of typical radionuclides dispersed from CAP1400 under normal operation was calculated with modified Gaussian model, considering mixed layer height, dry deposition, wet deposition, radioactive decay and so on. The atmospheric dispersion factors, ground deposition rate, individual dose and public dose were also investigated to estimate the radioactive effects of CAP1400 under normal operation on surrounding environment and human beings. The radioactive impact pathways on the public through atmosphere, such as immersion irradiation in the smoke plume, internal irradiation from ingestion and inhalation and external irradiation from surface deposition were briefly introduced with focus on the comparison of the maximum individual effective dose to different group from atmospheric dispersion. All computation results show that the maximum individual irradiation dose happened to children with total effective irradiation dose of 4.52E−03 mSv/y, which was lower than the public irradiation limit of 0.25 mSv/y

  4. On nuclear power plant uprating

    International Nuclear Information System (INIS)

    Ho, S. Allen; Bailey, James V.; Maginnis, Stephen T.

    2004-01-01

    Power uprating for commercial nuclear power plants has become increasingly attractive because of pragmatic reasons. It provides quick return on investment and competitive financial benefits, while involving low risks regarding plant safety and public objection. This paper briefly discussed nuclear plant uprating guidelines, scope for design basis analysis and engineering evaluation, and presented the Salem nuclear power plant uprating study for illustration purposes. A cost and benefit evaluation of the Salem power uprating was also included. (author)

  5. Impacting effects of seismic loading in feeder pipes of PHWR power plants

    International Nuclear Information System (INIS)

    Kumar, R.

    1996-01-01

    The core of a pressurized heavy water reactor (PHWR) consists of a large number of fuel channels. These fuel channels are connected to the feeder pipes through which the heavy water flows and transports heat from the reactor core to the steam generators. The feeder pipes are several hundreds in number. They run close to each other with small gaps and have several bends. Thus they represent a complex piping system. Under seismic loading, the adjacent feeder pipes may impact each other. In this paper a simplified procedure has been established to assess such impacting effects. The results of the proposed analysis include bending moment and impact force, which provide the stresses due to impacting effects. These results are plotted in nondimensional form so that they could be utilized for any set of feeder pipes. The procedure used for studying the impacting effects includes seismic analysis of individual feeder pipes without impacting effects, selection of pipes for impact analysis, and estimating their maximum impact velocity. Based on the static and dynamic characteristics of the selected feeder pipes, the maximum bending moment, impact force, and stresses are obtained. The results of this study are useful for quick evaluation of the impacting effects in feeder pipes

  6. Assessment of Nuclear Power Plant Impact to the Environment: Effect of Sea Water Temperature Increase on Plankton Population

    International Nuclear Information System (INIS)

    Tjahaja, I P; Pujadi; Supriharyono; Aviati, N; Ruswahyun; Busono, H

    1996-01-01

    Research to study the effect of sea water temperature increase on plankton population had been carried out to predict nuclear power plant impact to the environment. Plankton collected from Jepara waters, Muria Peninsula, was grown on growth medium i.e. sea water enriched with silicate fertilizer. Plankton growth was maintained at temperature varied from 34oC to 46oC and the amount of plankton individu was counted twice a day until it was reduced about 95%. The results showed that the reduction of amount of plankton individu occurred on the medium with temperature above the ambient temperature (34oC). The rate of reduction is linear to the temperature increase. There is no plankton survived at temperature above 40oC for more than 24 hours

  7. Heat supply from nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Stach, V [Ustav Jaderneho Vyzkumu CSKAE, Rez (Czechoslovakia)

    1978-05-01

    The current state of world power production and consumption is assessed. Prognoses made for the years 1980 to 2000 show that nuclear energy should replace the major part of fossil fuels not only in the production of power but also in the production of heat. In this respect high-temperature reactors are highly prospective. The question is discussed of the technical and economic parameters of dual-purpose heat and power plants. It is, however, necessary to solve problems arising from the safe siting of nuclear heat and power plants and their environmental impacts. The economic benefits of combined power and heat production by such nuclear plants is evident.

  8. Nuclear power plant life management

    International Nuclear Information System (INIS)

    Rorive, P.; Berthe, J.; Lafaille, J.P.; Eussen, G.

    1998-01-01

    Several definitions can be given to the design life of a nuclear power plant just as they can be attributed to the design life of an industrial installation: the book-keeping life which is the duration of the provision for depreciation of the plant, the licensed life which corresponds to the duration for which the plant license has been granted and beyond which a new license should be granted by the safety authorities, the design life which corresponds to the duration specified for ageing and fatigue calculations in the design of some selected components during the plant design phase, the technical life which is the duration of effective technical operation and finally the economic life corresponding to the duration of profitable operation of the plant compared with other means of electricity production. Plant life management refers to the measures taken to cope with the combination of licensed, design, technical and economical life. They can include repairs and replacements of components which have arrived to the end of their life due to known degradation processes such as fatigue, embrittlement, corrosion, wear, erosion, thermal ageing. In all cases however, it is of great importance to plan the intervention so as to minimise the economic impact. Predictive maintenance is used together with in-service inspection programs to fulfil this goal. The paper will go over the methodologies adopted in Belgium in all aspects of electrical, mechanical and civil equipment for managing plant life. (author)

  9. Advanced power plant materials, design and technology

    Energy Technology Data Exchange (ETDEWEB)

    Roddy, D. (ed.) [Newcastle University (United Kingdom). Sir Joseph Swan Institute

    2010-07-01

    The book is a comprehensive reference on the state of the art of gas-fired and coal-fired power plants, their major components and performance improvement options. Selected chapters are: Integrated gasification combined cycle (IGCC) power plant design and technology by Y. Zhu, and H. C. Frey; Improving thermal cycle efficiency in advanced power plants: water and steam chemistry and materials performance by B. Dooley; Advanced carbon dioxide (CO{sub 2}) gas separation membrane development for power plants by A. Basile, F. Gallucci, and P. Morrone; Advanced flue gas cleaning systems for sulphur oxides (SOx), nitrogen oxides (NOx) and mercury emissions control in power plants by S. Miller and B.G. Miller; Advanced flue gas dedusting systems and filters for ash and particulate emissions control in power plants by B.G. Miller; Advanced sensors for combustion monitoring in power plants: towards smart high-density sensor networks by M. Yu and A.K. Gupta; Advanced monitoring and process control technology for coal-fired power plants by Y. Yan; Low-rank coal properties, upgrading and utilisation for improving the fuel flexibility of advanced power plants by T. Dlouhy; Development and integration of underground coal gasification (UCG) for improving the environmental impact of advanced power plants by M. Green; Development and application of carbon dioxide (CO{sub 2}) storage for improving the environmental impact of advanced power plants by B. McPherson; and Advanced technologies for syngas and hydrogen (H{sub 2}) production from fossil-fuel feedstocks in power plants by P. Chiesa.

  10. Garigliano nuclear power plant

    International Nuclear Information System (INIS)

    1976-03-01

    During the period under review, the Garigliano power station produced 1,028,77 million kWh with a utilization factor of 73,41% and an availability factor of 85,64%. The disparity between the utilization and availability factors was mainly due to a shutdown of about one and half months owing to lack of staff at the plant. The reasons for nonavailability (14.36%) break down as follows: nuclear reasons 11,49%; conventional reasons 2,81%; other reasons 0,06%. During the period under review, no fuel replacements took place. The plant functioned throughout with a single reactor reticulation pump and resulting maximum available capacity of 150 MWe gross. After the month of August, the plant was operated at levels slightly below the maximum available capacity in order to lengthen the fuel cycle. The total number of outages during the period under review was 11. Since the plant was brought into commercial operation, it has produced 9.226 million kWh

  11. The economic, environmental and public health impacts of new power plants: a sequential inter industry model integrated with GIS data

    Energy Technology Data Exchange (ETDEWEB)

    Avelino, Andre F.T.; Hewings, Geoffrey J.D.; Guilhoto, Joaquim J.M. [Universidade de Sao Paulo (FEA/USP), SE (Brazil). Fac. de Administracao e Contabilidade

    2010-07-01

    The electrical sector is responsible for a considerable amount of greenhouse gases emissions worldwide, but also the one in which modern society depends the most for maintenance of quality of life as well as the functioning of economic and social activities. Invariably, even CO2 emission-free power plants have some indirect environmental impacts due to the economic effects they produce during their life cycle (construction, O and M and decommissioning). Thus, sustainability issues should be always considered in energy planning, by evaluating the balance of positive/negative externalities on different areas of the country. This study aims to introduce a social-environmental economic model, based on a Regional Sequential Inter industry Model (SIM) integrated with geoprocessing data, in order to identify economic, pollution and public health impacts in state level for energy planning analysis. The model is based on the Impact Pathway Approach Methodology, using geoprocessing to locate social-environmental variables for dispersion and health evaluations. The final goal is to provide an auxiliary tool for policy makers to assess energy planning scenarios in Brazil. (author)

  12. Mobile power plant units

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, R

    1979-10-05

    Diesel engines of the MaK line 282 AK/332 with a cylinder power up to 160 kW are used, either as 6-cylinder or 8-cylinder in-line engine or as 12-cylinder V engine. Fuel consumption is between 207 and 212 g/kW. The engine is mounted on a frame, together with a generator. The fuel reserve in the tank will last for 8 hours. The lubricating system, the cooling water and starting air system, the switchboard system, and the frame are described. The switchboard plant is mounted either on a skid undercarriage or on the undercarriage. The plant can be operated independently or parallel to the network. The unit can be remote-controlled via push buttons or control knobs. A picture is presented of a mobile diesel aggregate which is in service in Libya.

  13. Risk analysis for nuclear power plants

    International Nuclear Information System (INIS)

    Koelzer, W.

    1983-01-01

    The German risk analysis program for nuclear power plants aiming at the man and the environment is presented. An accident consequence model to calculate the radiological impact and the potential health effects is described. (E.G.) [pt

  14. Comparative studies between nuclear power plants and hydroelectric power plants

    International Nuclear Information System (INIS)

    Menegassi, J.

    1984-01-01

    This paper shows the quantitative evolution of the power plants in the main countries of the world. The Brazilian situation is analysed, with emphasys in the technical and economical aspects related to power production by hidroelectric or nuclear power plants. The conclusion is that the electricity produced by hidro power plants becomes not economics when is intended to be produced at large distances from the demand centers. (Author) [pt

  15. Socioeconomic impact assessment and nuclear power plant licensing, Greene County, New York

    International Nuclear Information System (INIS)

    Peelle, E.

    1980-01-01

    The paper reviews the setting, participants and status of the joint federal-state hearings, findings of the FES, problems of conducting social impact assessment (SIA) for the GCNPP, and the nature and effect of public participation in the formal, legalistic hearings process. The GCNPP is evaluated in terms of trends in Atomic Energy Commission-Nuclear Regulatory Commission social impact assessments from 1972 to 1979. Progress in the adequacy and relevance of social impact assessment is defined according to steps in a lengthy, evolutionary legitimation process

  16. Socioeconomic impact assessment and nuclear power plant licensing, Greene County, New York

    Energy Technology Data Exchange (ETDEWEB)

    Peelle, E

    1980-01-01

    The paper reviews the setting, participants and status of the joint federal-state hearings, findings of the FES, problems of conducting social impact assessment (SIA) for the GCNPP, and the nature and effect of public participation in the formal, legalistic hearings process. The GCNPP is evaluated in terms of trends in Atomic Energy Commission-Nuclear Regulatory Commission social impact assessments from 1972 to 1979. Progress in the adequacy and relevance of social impact assessment is defined according to steps in a lengthy, evolutionary legitimation process.

  17. Nuclear power plant disasters

    International Nuclear Information System (INIS)

    Trott, K.R.

    1979-01-01

    The possibility of a nuclear power plant disaster is small but not excluded: in its event, assistance to the affected population mainly depends on local practitioners. Already existing diseases have to be diagnosed and treated; moreover, these physicians are responsible for the early detection of those individuals exposed to radiation doses high enough to induce acute illness. Here we present the pathogenesis, clinical development and possible diagnostic and therapeutical problems related to acute radiation-induced diseases. The differentiation of persons according to therapy need and prognosis is done on the sole base of the clinical evidence and the peripheral blood count. (orig.) [de

  18. Demonstration tokamak power plant

    International Nuclear Information System (INIS)

    Abdou, M.; Baker, C.; Brooks, J.; Ehst, D.; Mattas, R.; Smith, D.L.; DeFreece, D.; Morgan, G.D.; Trachsel, C.

    1983-01-01

    A conceptual design for a tokamak demonstration power plant (DEMO) was developed. A large part of the study focused on examining the key issues and identifying the R and D needs for: (1) current drive for steady-state operation, (2) impurity control and exhaust, (3) tritium breeding blanket, and (4) reactor configuration and maintenance. Impurity control and exhaust will not be covered in this paper but is discussed in another paper in these proceedings, entitled Key Issues of FED/INTOR Impurity Control System

  19. Siting nuclear power plants

    International Nuclear Information System (INIS)

    Yellin, J.; Joskow, P.L.

    1980-01-01

    The first edition of this journal is devoted to the policies and problems of siting nuclear power plants and the question of how far commercial reactors should be placed from urban areas. The article is divided into four major siting issues: policies, risk evaluation, accident consequences, and economic and physical constraints. One concern is how to treat currently operating reactors and those under construction that were established under less-stringent criteria if siting is to be used as a way to limit the consequences of accidents. Mehanical cost-benefit analyses are not as appropriate as the systematic use of empirical observations in assessing the values involved. Stricter siting rules are justified because (1) opposition because of safety is growing: (2) remote siting will make the industry more stable; (3) the conflict is eliminated between regulatory policies and the probability basis for nuclear insurance; and (4) joint ownership of utilities and power-pooling are increasing. 227 references, 7 tables

  20. Economic evaluation of tokamak power plants

    International Nuclear Information System (INIS)

    Reid, R.L.; Steiner, D.

    1977-01-01

    This study reports the impact of plasma operating characteristics, engineering options, and technology on the capital cost trends of tokamak power plants. Tokamak power systems are compared to other advanced energy systems and found to be economically competitive. A three-phase strategy for demonstrating commercial feasibility of fusion power, based on a common-site multiple-unit concept, is presented

  1. Pulsed nuclear power plant

    International Nuclear Information System (INIS)

    David, C.V.

    1986-01-01

    This patent describes a nuclear power plant. This power plant consists of: 1.) a cavity; 2.) a detonatable nuclear device in a central region of the cavity; 3.) a working fluid inside of the cavity; 4.) a method to denote a nuclear device inside of the cavity; 5.) a mechanical projection from an interior wall of the cavity for recoiling to absorb a shock wave produced by the detonation of the nuclear device and thereby protecting the cavity from damage. A plurality of segments defines a shell within the cavity and a plurality of shock absorbers, each connecting a corresponding segment to a corresponding location on the wall of the cavity. Each of these shock absorbers regulate the recoil action of the segments; and 6.) means for permitting controlled extraction of a quantity of hot gases from the cavity produced by the vaporization of the working fluid upon detonation of the nuclear device. A method of generating power is also described. This method consists of: 1.) introducing a quantity of water in an underground cavity; 2.) heating the water in the cavity to form saturated steam; 3.) detonating a nuclear device at a central location inside the cavity; 4.) recoiling plate-like elements inside the cavity away from the central location in a mechanically regulated and controlled manner to absorb a shock wave produced by the nuclear device detonation and thereby protect the underground cavity against damage; 5.) extracting a quantity of superheated steam produced by the detonation of the nuclear device; and 6.) Converting the energy in the extracted superheated steam into electrical power

  2. Wind power plant system services

    DEFF Research Database (Denmark)

    Basit, Abdul; Altin, Müfit

    Traditionally, conventional power plants have the task to support the power system, by supplying power balancing services. These services are required by the power system operators in order to secure a safe and reliable operation of the power system. However, as in the future the wind power...... is going more and more to replace conventional power plants, the sources of conventional reserve available to the system will be reduced and fewer conventional plants will be available on-line to share the regulation burden. The reliable operation of highly wind power integrated power system might...... then beat risk unless the wind power plants (WPPs) are able to support and participate in power balancing services. The objective of this PhD project is to develop and analyse control strategies which can increase the WPPs capability to provide system services, such as active power balancing control...

  3. The level of air pollution in the impact zone of coal-fired power plant (Karaganda City) using the data of geochemical snow survey (Republic of Kazakhstan)

    OpenAIRE

    Adil'bayeva, Т. E.; Talovskaya, Anna Valerievna; Yazikov, Yegor (Egor) Grigoryevich; Matveenko, Irina Alekseevna

    2016-01-01

    Coal-fired power plants emissions impact the air quality and human health. Of great significance is assessment of solid airborne particles emissions from those plants and distance of their transportation. The article presents the results of air pollution assessment in the zone of coal-fired power plant (Karaganda City) using snow survey. Based on the mass of solid airborne particles deposited in snow, time of their deposition on snow at the distance from 0.5 to 4.5 km a value of dust load has...

  4. Evaluating the impact of the carbon dioxide capturing process on the indices of economic efficiency in thermal power plants

    International Nuclear Information System (INIS)

    Marukhyan, V.Z.; Elbakyan, S.H.

    2017-01-01

    Taking into account the input of carbon dioxide as a greenhouse gas in the global warming process, the technological solutions of its capturing, and the implementation possibilities in environmentally safe thermal power plants are considered. In power plants equipped with effective systems for cleaning the fuel gas and the coal gasification, the influence of the CO 2 reduction and realization of quotes on the indices of economic efficiency is estimated

  5. Industrial safety in power plants

    International Nuclear Information System (INIS)

    1987-01-01

    The proceedings of the VGB conference 'Industrial safety in power plants' held in the Gruga-Halle, Essen on January 21 and 22, 1987, contain the papers reporting on: Management responsibility for and legal consequences of industrial safety; VBG 2.0 Industrial Accident Prevention Regulation and the power plant operator; Operational experience gained with wet-type flue gas desulphurization systems; Flue gas desulphurization systems: Industrial-safety-related requirements to be met in planning and operation; the effects of the Hazardous Substances Ordinance on power plant operation; Occupational health aspects of heat-exposed jobs in power plants; Regulations of the Industrial Accident Insurance Associations concerning heat-exposed jobs and industrial medical practice; The new VBG 30 Accident Prevention Regulation 'Nuclear power plants'; Industrial safety in nuclear power plants; safe working on and within containers and confined spaces; Application of respiratory protection equipment in power plants. (HAG) [de

  6. Extended value-impact decision making methodology for nuclear power plant modifications

    International Nuclear Information System (INIS)

    Nelson, P.F.; Kastenberg, W.E.

    1985-01-01

    Value-impact is the term used by the Nuclear Regulatory Commission (NRC) to define what is traditionally known as cost-benefit analysis; values measure the beneficial consequences of a proposed action, impacts measure the adverse consequences, i.e. costs of the proposed action. In the regulatory framework, value-impact or cost-benefit is but one input to decision making. The present study was performed in order to illustrate how decision makers can utilize a more structured method for determining nuclear regulatory policy. In order to be useful, the method must treat all dominant factors that influence a decision; including economic, as well as societal factors such as environmental, health and safety. The method must also allow decisions to be consistent with the preferences of the decision maker as well as other interested groups. Major problems in decision making are how to incorporate non-quantifiable attributes in the method and how to reach consensus between opposing viewpoints. The Analytic Hierarchy Process (AHP) can attack these issues by making it possible to structure the decision in a way that subjective input can be included. In this paper, the AHP is developed and used to rank the value/impact ratios of alternative decay heat removal systems. It is believed that use of the AHP can decrease limitations present in a current value-impact analysis

  7. The impact of pulsed irradiation upon neutron activation calculations for inertial and magnetic fusion energy power plants

    International Nuclear Information System (INIS)

    Latkowski, J.F.; Sanz, J.; Vujic, J.L.

    1996-01-01

    Inertial fusion energy (IFE) and magnetic fusion energy (MFE) power plants will probably operate in a pulsed mode. The two different schemes, however, will have quite different time periods. Typical repetition rates for IFE power plants will be 1-5 Hz. MFE power plants will ramp up in current for about 1 hour, shut down for several minutes, and repeat the process. Traditionally, activation calculations for IFE and MFE power plants have assumed continuous operation and used either the ''steady state'' (SS) or ''equivalent steady state'' (ESS) approximations. It has been suggested recently that the SS and ESS methods may not yield accurate results for all radionuclides of interest. The present work expands that of Sisolak, et al. by applying their formulae to conditions which might be experienced in typical IFE and MFE power plants. In addition, complicated, multi-step reaction/decay chains are analyzed using an upgraded version of the ACAB radionuclide generation/depletion code. Our results indicate that the SS method is suitable for application to MFE power plant conditions. We also find that the ESS method generates acceptable results for radionuclides with half-lives more than a factor of three greater than the time between pulses. For components that are subject to 0.05 Hz (or more frequent) irradiation (such as coolant), use of the ESS method is recommended. For components or materials that are subject to less frequent irradiation (such as high-Z target materials), pulsed irradiation calculations should be used

  8. How organisational behaviours and human factors can positively impact contractors to nuclear power plants

    International Nuclear Information System (INIS)

    Arnaldos Gonzalez, A.; Walker-Sutton, J.; Shannon, M.; Mendoza Garcia, J.

    2012-01-01

    Organisational behaviours have a significant impact on individual and group behaviours but are frequently ignored during the design, planning and scheduling of work or when conducting an investigation of events. Why should it matter? It is important to calculate the personal and organisational impact and cost of those elements which contribute to organisational safety. We look at two nuclear contractor organisations (one in Spain and one in the UK) that are actively making a positive difference to their behaviours in a commercial nuclear environment. They are creating a better business environment for their staff, and a robust business differentiator for future work with their clients. We consider what the cost and impact is of the changes they have made to their organisational behaviours.

  9. The assessment of impact on nuclear power plant structures in the United Kingdom

    International Nuclear Information System (INIS)

    Fullard, K.; Baum, M.R.

    1991-01-01

    Impact research in the United Kingdom has embraced a wide range of topics during the last fifteen years and advice has been provided in the form of guidelines for use in safety assessments and design studies. It is now the intention to produce a comprehensive Impact Assessment Procedure encompassing the definition of loading, whipping pipe effects and the response of steel and concrete targets. This paper is restricted to introducing the methods used for characterising missiles from pressurised vessels and for determining the impact damage produced in concrete targets. Considerable reliance has been placed on the interpretation of experimental data and guidance is therefore limited by the availability of such data. This paper indicates the extent to which advice can be given and the issues which still need further attention. An example is given of the use of the methods for characterising missiles from a cylindrical pressure vessel. (orig.)

  10. Nuclear Power Plant 1996

    International Nuclear Information System (INIS)

    1997-01-01

    Again this year, our magazine presents the details of the conference on Spanish nuclear power plant operation held in February and that was devoted to 1996 operating results. The Protocol for Establishment of a New Electrical Sector Regulation that was signed last December will undoubtedly represent a new challenge for the nuclear industry. By clearing stating that current standards of quality and safety should be maintained or even increased if possible, the Protocol will force the Sector to improve its productivity, which is already high as demonstrated by the results of the last few years described during this conference and by recent sectorial economic studies. Generation of a nuclear kWh that can compete with other types of power plants is the new challenge for the Sector's professionals, who do not fear the new liberalization policies and approaching competition. Lower inflation and the resulting lower interest rates, apart from being representative indices of our economy's marked improvement, will be very helpful in facing this challenge. (Author)

  11. Environmental impact efficiency of natural gas combined cycle power plants: A combined life cycle assessment and dynamic data envelopment analysis approach.

    Science.gov (United States)

    Martín-Gamboa, Mario; Iribarren, Diego; Dufour, Javier

    2018-02-15

    The energy sector is still dominated by the use of fossil resources. In particular, natural gas represents the third most consumed resource, being a significant source of electricity in many countries. Since electricity production in natural gas combined cycle (NGCC) plants provides some benefits with respect to other non-renewable technologies, it is often seen as a transitional solution towards a future low‑carbon power generation system. However, given the environmental profile and operational variability of NGCC power plants, their eco-efficiency assessment is required. In this respect, this article uses a novel combined Life Cycle Assessment (LCA) and dynamic Data Envelopment Analysis (DEA) approach in order to estimate -over the period 2010-2015- the environmental impact efficiencies of 20 NGCC power plants located in Spain. A three-step LCA+DEA method is applied, which involves data acquisition, calculation of environmental impacts through LCA, and the novel estimation of environmental impact efficiency (overall- and term-efficiency scores) through dynamic DEA. Although only 1 out of 20 NGCC power plants is found to be environmentally efficient, all plants show a relatively good environmental performance with overall eco-efficiency scores above 60%. Regarding individual periods, 2011 was -on average- the year with the highest environmental impact efficiency (95%), accounting for 5 efficient NGCC plants. In this respect, a link between high number of operating hours and high environmental impact efficiency is observed. Finally, preliminary environmental benchmarks are presented as an additional outcome in order to further support decision-makers in the path towards eco-efficiency in NGCC power plants. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. A Process for Evaluating Adverse Environmental Impacts by Cooling-Water System Entrainment at a California Power Plant

    Directory of Open Access Journals (Sweden)

    C.P. Ehrler

    2002-01-01

    Full Text Available A study to determine the effects of entrainment by the Diablo Canyon Power Plant (DCPP was conducted between 1996 and 1999 as required under Section 316(b of the Clean Water Act. The goal of this study was to present the U.S. Environmental Protection Agency (EPA and Central Coast Regional Water Quality Control Board (CCRWQCB with results that could be used to determine if any adverse environmental impacts (AEIs were caused by the operation of the plant’s cooling-water intake structure (CWIS. To this end we chose, under guidance of the CCRWQCB and their entrainment technical working group, a unique approach combining three different models for estimating power plant effects: fecundity hindcasting (FH, adult equivalent loss (AEL, and the empirical transport model (ETM. Comparisons of the results from these three approaches provided us a relative measure of confidence in our estimates of effects. A total of 14 target larval fish taxa were assessed as part of the DCPP 316(b. Example results are presented here for the kelp, gopher, and black-and-yellow (KGB rockfish complex and clinid kelpfish. Estimates of larval entrainment losses for KGB rockfish were in close agreement (FH is approximately equals to 550 adult females per year, AEL is approximately equals to 1,000 adults [male and female] per year, and ETM = larval mortality as high as 5% which could be interpreted as ca. 2,600 1 kg adult fish. The similar results from the three models provided confidence in the estimated effects for this group. Due to lack of life history information needed to parameterize the FH and AEL models, effects on clinid kelpfish could only be assessed using the ETM model. Results from this model plus ancillary information about local populations of adult kelpfish suggest that the CWIS might be causing an AEI in the vicinity of DCPP.

  13. The impact of Ignalina Nuclear Power Plant (INPP) effluents on fish

    International Nuclear Information System (INIS)

    Astrauskas, A.; Bernotas, E.; Didrikas, T.

    1997-01-01

    Successive changes of the ecosystems, censor structure and functioning in the cooling reservoir of the Ignalina NPP - lake Drukshiai are continuing so far. The plant working at full capacity, the territory of the lake due to thermogradient conditions is expanding considerably, not seldom exceeding the hygienic norms. Under such conditions the volume of cold water masses is notably decreasing, and the limit of temperature jump becomes lower. Changes and elimination of species in the ichtyocenosis of the lake are taking place, exceeding the rates typical to the development of natural water reservoirs. The pelagic fish populations were observed from 1979 till 1995. During fish population investigation hydroacoustic technique was applied. Research into the fish population structure and functioning discovered the existence of some adaptation processes.That is confirmed by the decrease of fish in the lake and natural habitat during the construction of the plant and first years of its exploitation. Besides, a partial restoration of the species is observed in the recent years. In some species, adaptive possibilities to not quite typical life conditions have been revealed (vendace), others practically became extinct (smelt), while still other species have properly adapted themselves to the changed life conditions and remained abundant (roach, silver bream, perch). (author). 17 refs., 9 figs

  14. Nuclear power plants

    International Nuclear Information System (INIS)

    Ushijima, Susumu.

    1984-01-01

    Purpose: To enable to prevent the degradation in the quality of condensated water in a case where sea water leakage should occur in a steam condenser of a BWR type nuclear power plant. Constitution: Increase in the ion concentration in condensated water is detected by an ion concentration detector and the leaking factor of sea water is calculated in a leaking factor calculator. If the sea water leaking factor exceeds a predetermined value, a leak generation signal is sent from a judging device to a reactor power control device to reduce the reactor power. At ehe same tiem, the leak generation signal is also sent to a steam condenser selection and isolation device to interrupt the sea water pump of a specified steam condenser based on the signal from the ion concentration detector, as well as close the inlet and outlet valves while open vent and drain valves to thereby forcively discharge the sea water in the cooling water pipes. This can keep the condensate desalting device from ion breaking and prevent the degradation in the quality of the reactor water. (Horiuchi, T.)

  15. Management of waste heat at nuclear power plants: Its potential impact on the environment and its possible economic use

    International Nuclear Information System (INIS)

    Tsai, Y.H.

    1987-01-01

    The efficacy of the disposal of waste heat from nuclear power plants by means of once-through and closed-cycle cooling systems is examined in the context of the physical aspects of water quality standards and guidelines for thermal discharges. Typical thermal standards for each of the four classes of water bodies (rivers, lakes, estuaries, and coastal waters) are identified. Examples of thermal standards established for once-through cooling on open coastal waters are presented. The design and general layout of various types of cooling systems are reviewed. The advantages and disadvantages of each of the cooling systems are presented, with particular emphasis on the discussion of potential environmental impacts. Modeling techniques available for impact assessment are presented. Proper selection and application of the models depend on the availability of site characteristics and understanding of the modeling techniques. Guidelines for choosing an appropriate model are presented. Various methods have been developed for the beneficial use of waste heat largely dissipated to the environment. Examples and associated problems of waste-heat utilization are discussed for agricultural, industrial, aquacultural, and residential uses

  16. Industry perceptions of the impact of the U.S. Nuclear Regulatory Commission on nuclear power plant activities. Draft report

    Energy Technology Data Exchange (ETDEWEB)

    Davis, A Bert; Pederson, Cynthia D

    1990-03-01

    Teams of senior managers from the U.S. Nuclear Regulatory Commission (NRC) surveyed licensee staff members representing 13 nuclear power utilities from across the country to obtain their candid views of the effectiveness and impact of NRC regulatory activities. Licensee comments addressed the full scope of NRC activities and the impact of agency actions on licensee resources, staff performance, planning and scheduling, and organizational effectiveness. The principal themes of the survey respondents' comments are that (1) licensees acquiesce to NRC requests to avoid poor ratings on NRC Systematic Assessment of Licensee Performance (SALP) reports and the consequent financial and public perception problems that result, even if the requests require the expenditure of significant resources on matters of marginal safety significance, and (2) NRC so dominates licensee resources through its existing and changing formal and informal requirements that licensees believe that their plants, though not unsafe, would have better reliability, and may even achieve a higher degree of safety, if licensees were freer to manage their own resources. This draft report does not attempt to defend any NRC position; endorse or refute licensee perceptions; or explain any action taken by NRC in fulfilling its responsibilities to protect the health and safety of the public. Senior RC managers have made a preliminary evaluation of the information in this report and have made recommendations to address licensee concerns in some areas. The final evaluation and recommendations will be published at a later date as the final NUREG. (author)

  17. Hybrid combined cycle power plant

    International Nuclear Information System (INIS)

    Veszely, K.

    2002-01-01

    In case of re-powering the existing pressurised water nuclear power plants by the proposed HCCPP solution, we can increase the electricity output and efficiency significantly. If we convert a traditional nuclear power plant unit to a HCCPP solution, we can achieve a 3.2-5.5 times increase in electricity output and the achievable gross efficiency falls between 46.8-52% and above, depending on the applied solution. These figures emphasise that we should rethink our power plant technologies and we have to explore a great variety of HCCPP solutions. This may give a new direction in the development of nuclear reactors and power plants as well.(author)

  18. Accident prevention in power plants

    International Nuclear Information System (INIS)

    Steyrer, H.

    Large thermal power plants are insured to a great extent at the Industrial Injuries Insurance Institute of Instrument and Electric Engineering. Approximately 4800 employees are registered. The accident frequency according to an evaluation over 12 months lies around 79.8 per year and 1000 employees in fossil-fired power plants, around 34.1 per year and 1000 employees in nuclear power plants, as in nuclear power plants coal handling and ash removal are excluded. Injuries due to radiation were not registered. The crucial points of accidents are mechanical injuries received on solid, sharp-edged and pointed objects (fossil-fired power plants 28.6%, nuclear power plants 41.5%), stumbling, twisting or slipping (fossil-fired power plants 21.8%, nuclear power plants 19.5%) and injuries due to moving machine parts (only nuclear power plants 12.2%). However, accidents due to burns or scalds obtain with 4.2% and less a lower portion than expected. The accident statistics can explain this fact in a way that the typical power plant accident does not exist. (orig./GL) [de

  19. Occidental Geothermal, Inc. , Oxy geothermal power plant No. 1. Final environmental impact report

    Energy Technology Data Exchange (ETDEWEB)

    1981-12-01

    The project-specific environmental analysis covers the following: geology, soils, water resources, biology, air quality, noise, waste management, health, safety, transportation, energy and material resources, cultural resources, socioeconomics, public services, land use, and aesthetics. Other topics covered are: the cumulative envionmental analysis; unavoidable significant adverse environmental effects; irreversible environmental changes and irretrievable commitments of energy and materials; the relationship between local short-term uses of man's environment and the maintenance and enhancement of long-term productivity; growth-inducing impacts; and alternatives to the proposed action. (MHR)

  20. Impact of thermal power plant discharges on the coastal environment of Tuticorin

    International Nuclear Information System (INIS)

    Palanichamy, S.; Ragumaran, S.; Rajendran, A.

    2002-01-01

    In the present study an attempt is made to delineate the changes in the environmental quality caused due to effluent discharges from Tuticorin thermal power station. Water samples were collected from 19 stations covering three different zones. Plankton and benthic fauna were collected from 5 stations. The data indicated that environmental parameters like DO, pH and nutrients were slightly altered at zone II, while, water temperature was rather higher by about 8 degC above the ambient temperature. Further suspended solids, turbidity values were also found to be higher. The stations located near the hot effluent discharge (zone II) recorded poor plankton diversity and density. Benthic fauna was also found to be affected in the vicinity of the hot effluent discharges. The changes encountered during the study period are discussed in this paper. (author)

  1. Wuergassen nuclear power plant

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    The decision of the Federal Court of Administration concerns an application for immediate decommissioning of a nuclear power plant (Wuergassen reactor): The repeal of the permit granted. The decision dismisses the appeal for non-admission lodged by the plaintiffs against the ruling of the Higher Court of Administration (OVG) of North-Rhine Westphalia of December 19th 1988 (File no. 21 AK 8/88). As to the matter in dispute, the Federal Court of Administration confirms the opinion of the Higher Court of Administration. As to the headnotes, reference can be made to that decision. Federal Court of Administration, decision of April 5th 1989 - 7 B 47.89. Lower instance: OVG NW, Az.: 21 AK 8/88. (orig./RST) [de

  2. Nuclear power plant

    International Nuclear Information System (INIS)

    Uruma, Hiroshi

    1998-01-01

    In the first embodiment of the present invention, elements less activated by neutrons are used as reactor core structural materials placed under high neutron irradiation. In the second embodiment of the present invention, materials less activated by neutrons when corrosive materials intrude to a reactor core are used as structural materials constituting portions where corrosion products are generated. In the third embodiment, chemical species comprising elements less activated by neutrons are used as chemical species to be added to reactor water with an aim of controlling water quality. A nuclear power plant causing less radioactivity can be provided by using structural materials comprising a group of specific elements hardly forming radioactivity by activation of neutrons or by controlling isotope ratios. (N.H.)

  3. Nuclear power plant

    International Nuclear Information System (INIS)

    Schabert, H.P.

    1976-01-01

    A nuclear power plant is described which includes a steam generator supplied via an input inlet with feedwater heated by reactor coolant to generate steam, the steam being conducted to a steam engine having a high pressure stage to which the steam is supplied, and which exhausts the steam through a reheater to a low pressure stage. The reheater is a heat exchanger requiring a supply of hot fluid. To avoid the extra load that would be placed on the steam generator by using a portion of its steam output as such heating fluid, a portion of the water in the steam generator is removed and passed through the reheater, this water having received at least adequate heating in the steam generator to make the reheater effective, but not at the time of its removal being in a boiling condition

  4. Shiftwork, work scheduling and their impact upon operators in nuclear power plants

    International Nuclear Information System (INIS)

    Dahlgren, K.

    1988-01-01

    The risk for operator errors may increase during the night shift due to the influence from circadian rhythms, with variations in alertness and performance efficiency. Many of the more severe accidents and incidents have also occurred during night shifts. Although the problems of a decrease in performance capacity in connection with shiftwork cannot be eliminated several important measures can be taken to decrease the probability of it's occurrance. This paper deals with some of factors that have been shown to have a major impact upon the adjustment to shiftwork - the design of the shift schedule playing an important role. It is suggested that improvements are made in terms of incident reporting systems and in incident analyses to insure that proper remedies are applied regarding the problems associated with 24-hour operations

  5. Power plant removal costs

    International Nuclear Information System (INIS)

    Ferguson, J.S.

    1998-01-01

    The financial, regulatory and political significance of the estimated high removal costs of nuclear power plants has generated considerable interest in recent years, and the political significance has resulted in the Nuclear Regulatory Commission (NRC) eliminating the use of conventional depreciation accounting for the decontamination portion of the removal (decommissioning). While nuclear plant licensees are not precluded from utilizing conventional depreciation accounting for the demolition of non-radioactive structures and site restoration, state and federal utility regulators have not been favorably inclined to requests for this distinction. The realization that steam-generating units will be more expensive to remove, relative to their original cost, predates the realization that nuclear units will be expensive. However, the nuclear issues have overshadowed this realization, but are unlikely to continue to do so. Numerous utilities have prepared cost estimates for steam generating units, and this presentation discusses the implications of a number of such estimates that are a matter of public record. The estimates cover nearly 400 gas, oil, coal and lignite generating units. The earliest estimate was made in 1978, and for analysis purposes the author has segregated them between gas and oil units, and coal and lignite units

  6. Perspectives of nuclear power plants

    International Nuclear Information System (INIS)

    Vajda, Gy.

    2001-01-01

    In several countries the construction of nuclear power plants has been stopped, and in some counties several plants have been decommissioned or are planned to. Therefore, the question arises: have nuclear power plants any future? According to the author, the question should be reformulated: can mankind survive without nuclear power? To examine this challenge, the global power demand and its trends are analyzed. According to the results, traditional energy sources cannot be adequate to supply power. Therefore, a reconsideration of nuclear power should be imminent. The economic, environmental attractions are discussed as opposite to the lack of social support. (R.P.)

  7. Harmonics in a Wind Power Plant: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Preciado, V.; Madrigal, M.; Muljadi, E.; Gevorgian, V.

    2015-04-02

    Wind power generation has been growing at a very fast pace for the past decade, and its influence and impact on the electric power grid is significant. As in a conventional power plant, a wind power plant (WPP) must ensure that the quality of the power being delivered to the grid is excellent. At the same time, the wind turbine should be able to operate immune to small disturbances coming from the grid. Harmonics are one of the more common power quality issues presented by large WPPs because of the high switching frequency of the power converters and the possible nonlinear behavior from electric machines (generator, transformer, reactors) within a power plant. This paper presents a summary of the most important issues related to harmonics in WPPs and discusses practical experiences with actual Type 1 and Type 3 wind turbines in two WPPs.

  8. Wind-power plant

    Energy Technology Data Exchange (ETDEWEB)

    Kling, A

    1976-08-26

    The invention is concerned with a wind-power plant whose rotor axis is pivoted in the supporting structure and swingable around an axis of tilt, forming an angle with the rotor axis and the vertical axis, and allowing precession of the rotor. On changes of wind direction an electric positioning device is moving the rotor axis into the new direction in such a way that no precession forces are exerted on the supporting structure and this one may very easily be held. Instead of one rotor, also a type with two coaxial, co-planar countercurrent rotors may be used. Each of the two countercurrent rotors is carrying a number of magnetic poles, distributed all over the circumference, acting together with the magnetic poles of the other rotor. At least the poles of one rotor have electric line windings being connected by leads with a collector so that the two rotors form the two parts of a power generator being each rotatable with respect to the other ('stator' and 'rotor').

  9. Power generation by nuclear power plants

    International Nuclear Information System (INIS)

    Bacher, P.

    2004-01-01

    Nuclear power plays an important role in the world, European (33%) and French (75%) power generation. This article aims at presenting in a synthetic way the main reactor types with their respective advantages with respect to the objectives foreseen (power generation, resources valorization, waste management). It makes a fast review of 50 years of nuclear development, thanks to which the nuclear industry has become one of the safest and less environmentally harmful industry which allows to produce low cost electricity: 1 - simplified description of a nuclear power generation plant: nuclear reactor, heat transfer system, power generation system, interface with the power distribution grid; 2 - first historical developments of nuclear power; 3 - industrial development and experience feedback (1965-1995): water reactors (PWR, BWR, Candu), RBMK, fast neutron reactors, high temperature demonstration reactors, costs of industrial reactors; 4 - service life of nuclear power plants and replacement: technical, regulatory and economical lifetime, problems linked with the replacement; 5 - conclusion. (J.S.)

  10. Spatial distribution of mercury and other trace elements in recent lake sediments from central Alberta, Canada: An assessment of the regional impact of coal-fired power plants

    International Nuclear Information System (INIS)

    Sanei, H.; Goodarzi, F.; Outridge, P.M.

    2010-01-01

    These have been growing concerns over the environmental impacts of the coal-fired power plants in the western Canadian province of Alberta, which collectively comprise one of the largest point sources of Hg and other trace elements nationally. The overall cumulative impact of the power plants since the beginning of their activities several decades ago has been a critical question for industry, government agencies, and the research community. This paper aims to delineate the cumulative geographic extent of impact by investigating the spatial distribution of mercury and other trace elements of environmental concern in nine freshwater lakes, which cover the large area surrounding the coal-fired power plants in central Alberta, Canada. 210-Lead dating was used in conjunction with physical evidence of deposited fly ash to determine the sediments' age and hence the depths corresponding to the onset of coal-fired power generation in 1956. Total mean concentrations and fluxes of elements of environmental concern with integrated values since 1956 were then determined. The concentration values do not reflect the catastrophic oil spill at Lake Wabamun in 2005. The post-1956 flux rates of As, Cd, Co, Cr, Cu, Hg, Mo, Ni, Pb, Sb, V, W, and Zn were generally highest in sediment cores obtained from two lakes adjacent to power plants. However, the variable prevailing wind directions played an important role in determining the aerial distribution of Hg and other trace elements to the southeast and to the west of the power plants. Post-1956 fluxes of most elements declined downwind (westward), consistent with strong easterly winds transporting metal pollution further to the west of the power plants. However, spatial interpolation of the data suggested a major southern extension to the area of maximum metal deposition, which has not been sampled by this or previous studies in the region. An atmospheric model estimate of total Hg flux in 2007 near the Genesee power plant was

  11. Some power uprate issues in nuclear power plants

    International Nuclear Information System (INIS)

    Tipping, Philip

    2008-01-01

    Issues and themes concerned with nuclear power plant uprating are examined. Attention is brought to the fact that many candidate nuclear power plants for uprating have anyway been operated below their rated power for a significant part of their operating life. The key issues remain safety and reliability in operation at all times, irrespective of the nuclear power plant's chronological or design age or power rating. The effects of power uprates are discussed in terms of material aspects and expected demands on the systems, structures and components. The impact on operation and maintenance methods is indicated in terms of changes to the ageing surveillance programmes. Attention is brought to the necessity checking or revising operator actions after power up-rating has been implemented

  12. The level of air pollution in the impact zone of coal-fired power plant (Karaganda City) using the data of geochemical snow survey (Republic of Kazakhstan)

    Science.gov (United States)

    Adil'bayeva, T. E.; Talovskaya, A. V.; Yazikov, Ye G.; Matveenko, I. A.

    2016-09-01

    Coal-fired power plants emissions impact the air quality and human health. Of great significance is assessment of solid airborne particles emissions from those plants and distance of their transportation. The article presents the results of air pollution assessment in the zone of coal-fired power plant (Karaganda City) using snow survey. Based on the mass of solid airborne particles deposited in snow, time of their deposition on snow at the distance from 0.5 to 4.5 km a value of dust load has been determined. It is stated that very high level of pollution is observed at the distance from 0.5 to 1 km. there is a trend in decrease of dust burden value with the distance from the stacks of coal-fired power plant that may be conditioned by the particle size and washing out smaller ash particles by ice pellets forming at freezing water vapour in stacks of the coal-fired power plant. Study in composition of solid airborne particles deposited in snow has shown that they mainly contain particulates of underburnt coal, Al-Si- rich spheres, Fe-rich spheres, and coal dust. The content of the particles in samples decreases with the distance from the stacks of the coal-fired power plant.

  13. Brighter for small power plants

    International Nuclear Information System (INIS)

    Haaland, Leif

    2003-01-01

    The article presents a small tunnel drilling machine aimed at using for the construction of small hydroelectric power plants and mentions briefly some advantages economically and environmentally of both the machine and the power production solution

  14. Integral modeling and financial impact of the geothermal situation and power plant at Soultz-sous-Forets

    International Nuclear Information System (INIS)

    Heidinger, Ph.

    2010-01-01

    The science about deep Enhanced Geothermal Systems (EGS) is still an emerging process and for further spreading economics is the key of the technology. To understand the financial situation, a program for economic evaluation was developed. This software (Euronaut) is completely modularized and considers all cash flows. Projects like an EGS are wrapped into tree-like structures. Based on the results which were gained at Soultz-sous-Forets, two configurations were designed. The first EGS configuration consists of a simplified two well (doublet) system where the dependencies of all components (mainly the reservoir, wells, pumps and the heat-to-power conversion unit) are physically and economically linked together. The realization of these dependencies and their complex interactions enable a sensitivity analysis of the borehole depth and reservoir depth, respectively. As a result, depth dependent effective costs and revenues of an EGS plant with the geohydrological characteristics of Soultz-sous-Forets are determined. As a future development, the second configuration will adapt the actual situation at Soultz-sous-Forets with the individual features of all four wells (GPK1 - GPK4). Then, this model can be used for all kinds of sensitivity analyses to clarify the impact of certain components or to optimize the operation scheme; e.g. the flow rates. (author)

  15. The impact of the new investments in combined cycle gas turbine power plants on the Italian electricity price

    International Nuclear Information System (INIS)

    Fontini, Fulvio; Paloscia, Lorenzo

    2007-01-01

    The paper measures the variation of the electricity price in Italy within the next 10 years due to the recent investment flow in combined cycle gas turbine (CCGT) power plants. It starts by investigating the possibility of decoupling gas and oil prices on the basis of hypotheses about the amount of existing resources and plausible technical substitutability assumptions of the latter with the former. In particular, it is supposed that, in the Italian market, natural gas will play a crucial role which oil has had in power generation. The price of electricity stemming from natural gas is then calculated taking into account the role of the power mix restructuring that derives from the CCGT power plants investments. Under reasonable assumptions, it is shown that a net reduction of at least 17% on the electric price is likely to be expected. (author)

  16. Are atomic power plants saver than nuclear power plants

    International Nuclear Information System (INIS)

    Roeglin, H.C.

    1977-01-01

    It is rather impossible to establish nuclear power plants against the resistance of the population. To prevail over this resistance, a clarification of the citizens-initiatives motives which led to it will be necessary. This is to say: It is quite impossible for our population to understand what really heappens in nuclear power plants. They cannot identify themselves with nuclear power plants and thus feel very uncomfortable. As the total population feels the same way it is prepared for solidarity with the citizens-initiatives even if they believe in the necessity of nuclear power plants. Only an information-policy making transparent the social-psychological reasons of the population for being against nuclear power plants could be able to prevail over the resistance. More information about the technical procedures is not sufficient at all. (orig.) [de

  17. Employing modern power plant simulators in nuclear power plants

    International Nuclear Information System (INIS)

    Niedorf, V.; Storm, J.

    2005-01-01

    At the present state of the art, modern power plant simulators are characterized by new qualitative features, thus enabling operators to use them far beyond the traditional field of training. In its first part, this contribution presents an overview of the requirements to be met by simulators for multivalent uses. In part two, a survey of the uses and perspectives of simulation technology in power plants is presented on the basis of experience accumulated by Rheinmetall Defence Electronics (RDE).Modern simulators are shown to have applications by far exceeding traditional training areas. Modular client - sever systems on standard computers allow inexpensive uses to be designed at several levels, thus minimizing maintenance cost. Complex development and running time environments, like the SEMS developed by RDE, have made power plant simulators the workhorses of power plant engineers in all power plant areas. (orig.)

  18. The year 2000 power plant

    International Nuclear Information System (INIS)

    Roman, H.T.

    1989-01-01

    Every utility seeks extended service life from its existing power plants before building new ones. It is not easy to justify a new power plant. The licensing and cost of new plants have become uncertain. In response to these conditions, electric utilities are undertaking plant life-extension studies and, in some cases, reconditioning/upgrading old power plants to significantly increase useful service life. Other technologies like robotics and artificial intelligence/expert systems are also being developed to reduce operating and maintenance (O and M) expenses, to remove workers from potentially hazardous environments, and to reduce plant downtime. Together, these steps represent an interim solution, perhaps providing some relief for the next few decades. However, there are serious physical and economic limits to retrofitting new technology into existing power plants. Some old plants will simply be beyond their useful life and require retirement. In nuclear plants, for instance, retrofit may raise important and time-consuming licensing/safety issues. Based on their robotics and artificial intelligence experience, the authors of this article speculate bout the design of the year 2000 power plant - a power plant they feel will naturally incorporate liberal amounts of robotic and artificial intelligence technologies

  19. A preliminary investigation of the environmental impact of a thermal power plant in relation to PCB contamination.

    Science.gov (United States)

    Gedik, Kadir; Imamoglu, Ipek

    2011-07-01

    The most significant application of polychlorinated biphenyls (PCBs) is in transformers and capacitors. Therefore, power plants are important suspected sources for entry of PCBs into the environment. In this context, the levels and distribution of PCBs in sediment, soil, ash, and sludge samples were investigated around Seyitömer thermal power plant, Kütahya, Turkey. Moreover, identity and contribution of PCB mixtures were predicted using the chemical mass balance (CMB) receptor model. United States Environmental Protection Agency methods were applied during sample preparation, extraction (3540C), cleanup (3660B, 3665A, 3630C), and analysis (8082A). ΣPCB concentrations in the region ranged from not detected to 385 ng/g dry weight, with relatively higher contamination in sediments in comparison to soil, sludge, and ash samples collected from around the power plant. Congener profiles of the sediment and soil samples show penta-, hexa-, and hepta-chlorobiphenyls as the major homolog groups. The results from the CMB model indicate that PCB contamination is largely due to Clophen A60/A40 and Aroclor 1254/1254(late)/1260 release into the sediment and sludge samples around the thermal power plant. Since there are no other sources of PCBs in the region and the identity of PCB sources estimated by the CMB model mirrors PCB mixtures contained in transformers formerly used in the plant, the environmental contamination observed especially in sediments is attributed to the power plant. Release of PCBs over time, as indicated by the significant concentrations observed even in surface samples, emphasizes the importance of the need for better environmental management.

  20. A model for the release, dispersion and environmental impact of a postulated reactor accident from a submerged commercial nuclear power plant

    Science.gov (United States)

    Bertch, Timothy Creston

    1998-12-01

    Nuclear power plants are inherently suitable for submerged applications and could provide power to the shore power grid or support future underwater applications. The technology exists today and the construction of a submerged commercial nuclear power plant may become desirable. A submerged reactor is safer to humans because the infinite supply of water for heat removal, particulate retention in the water column, sedimentation to the ocean floor and inherent shielding of the aquatic environment would significantly mitigate the effects of a reactor accident. A better understanding of reactor operation in this new environment is required to quantify the radioecological impact and to determine the suitability of this concept. The impact of release to the environment from a severe reactor accident is a new aspect of the field of marine radioecology. Current efforts have been centered on radioecological impacts of nuclear waste disposal, nuclear weapons testing fallout and shore nuclear plant discharges. This dissertation examines the environmental impact of a severe reactor accident in a submerged commercial nuclear power plant, modeling a postulated site on the Atlantic continental shelf adjacent to the United States. This effort models the effects of geography, decay, particle transport/dispersion, bioaccumulation and elimination with associated dose commitment. The use of a source term equivalent to the release from Chernobyl allows comparison between the impacts of that accident and the postulated submerged commercial reactor plant accident. All input parameters are evaluated using sensitivity analysis. The effect of the release on marine biota is determined. Study of the pathways to humans from gaseous radionuclides, consumption of contaminated marine biota and direct exposure as contaminated water reaches the shoreline is conducted. The model developed by this effort predicts a significant mitigation of the radioecological impact of the reactor accident release

  1. Images of nuclear power plants

    International Nuclear Information System (INIS)

    Hashiguchi, Katsuhisa; Misumi, Jyuji; Yamada, Akira; Sakurai, Yukihiro; Seki, Fumiyasu; Shinohara, Hirofumi; Misumi, Emiko; Kinjou, Akira; Kubo, Tomonori.

    1995-01-01

    This study was conducted to check and see, using Hayashi's quantification method III, whether or not the respondents differed in their images of a nuclear power plant, depending on their demographic variables particularly occupations. In our simple tabulation, we compared subject groups of nuclear power plant employees with general citizens, nurses and students in terms of their images of a nuclear power plant. The results were that while the nuclear power plant employees were high in their evaluations of facts about a nuclear power plant and in their positive images of a nuclear power plant, general citizens, nurses and students were overwhelmingly high in their negative images of a nuclear power plant. In our analysis on category score by means of the quantification method III, the first correlation axis was the dimension of 'safety'-'danger' and the second correlation axis was the dimension of 'subjectivity'-'objectivity', and that the first quadrant was the area of 'safety-subjectivity', the second quadrant was the area of 'danger-subjectivity', the third quadrant as the area of 'danger-objectivity', and the forth quadrant was the area of 'safety-objectivity'. In our analysis of sample score, 16 occupation groups was compared. As a result, it was found that the 16 occupation groups' images of a nuclear power plant were, in the order of favorableness, (1) section chiefs in charge, maintenance subsection chiefs, maintenance foremen, (2) field leaders from subcontractors, (3) maintenance section members, operation section members, (4) employees of those subcontractors, (5) general citizens, nurses and students. On the 'safety-danger' dimension, nuclear power plant workers on the one hand and general citizens, nurses and students on the other were clearly divided in terms of their images of a nuclear power plant. Nuclear power plant workers were concentrated in the area of 'safety' and general citizens, nurses and students in the area of 'danger'. (J.P.N.)

  2. Nuclear energy and fuel mix. Impacts of new nuclear power plants after 2020 in the nuclear energy scenarios of the Energy Report 2008

    International Nuclear Information System (INIS)

    Seebregts, A.J.; Snoep, H.J.M.; Van Deurzen, J.; Lako, P.; Poley, A.D.

    2010-03-01

    This report presents facts and figures on new nuclear energy in the Netherlands, in the period after 2020. The information is meant to support a stakeholder discussion process on the role of new nuclear power in the transition to a sustainable energy supply for the Netherlands. The report covers a number of issues relevant to the subject. Facts and figures on the following issues are presented: Nuclear power and the power market (including impact of nuclear power on electricity market prices); Economic aspects (including costs of nuclear power and external costs and benefits, impact on end user electricity prices); The role of nuclear power with respect to security of supply; Sustainability aspects, including environmental aspects; The impact of nuclear power in three 'nuclear energy scenarios' for the Netherlands, within the context of a Northwest European energy market. The scenarios are: (1a) No new nuclear power in the Netherlands ('Base case'); (1b) After closure of the existing Borssele nuclear power plant by the end of 2033, the construction of new nuclear power plant that will operate in 2040. That plant is assumed to be designed not to have a serious core melt down accident (e.g. PBMR) (200 to 500 MWe); (2) New nuclear power shortly after closure the Borssele nuclear power plant in 2033 (1000 to 1600 MWe, 3rd Generation); (3) New nuclear power plants shortly after 2020 (2000 to 5000 MWe, 3rd Generation). Two electricity demand scenario background scenario variants have been constructed based on an average GDP growth of about 2% per year up to 2040. The first variant is based on a steadily growing electricity demand and on currently established NL and EU policies and instruments. It is expected to be largely consistent with a new and forthcoming reference projection 'Energy and Emissions 2010-2020' for the Netherlands (published by ECN and PBL in 2010). A lower demand variant is based on additional energy savings and on higher shares of renewable

  3. Nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Urata, Hidehiro; Oya, Takashi

    1996-11-05

    The present invention provides a highly safe light water-cooled type nuclear power plant capable of reducing radiation dose by suppressing deposition of activated corrosion products by a simple constitution. Namely, equipments and pipelines for fluid such as pumps at least in one of fluid systems such as a condensate cleanup system are constituted by a material containing metal species such as Zn having an effect of suppressing deposition of radioactivity. Alternatively, the surface of these equipments and pipelines for fluids on which water passes is formed by a coating layer comprising a material containing a metal having a radiation deposition suppressing effect. As a result, radioactivity deposited on the equipments and pipelines for fluids is reduced. In addition, since the method described above may be applied only at least to a portion of the members constituting at least one of the systems for fluids, it is economical. Accordingly, radiation dose upon inspection of equipments and pipelines for fluids can be reduced simply and reliably. (I.S.)

  4. Nuclear power plant

    International Nuclear Information System (INIS)

    Urata, Hidehiro; Oya, Takashi.

    1996-01-01

    The present invention provides a highly safe light water-cooled type nuclear power plant capable of reducing radiation dose by suppressing deposition of activated corrosion products by a simple constitution. Namely, equipments and pipelines for fluid such as pumps at least in one of fluid systems such as a condensate cleanup system are constituted by a material containing metal species such as Zn having an effect of suppressing deposition of radioactivity. Alternatively, the surface of these equipments and pipelines for fluids on which water passes is formed by a coating layer comprising a material containing a metal having a radiation deposition suppressing effect. As a result, radioactivity deposited on the equipments and pipelines for fluids is reduced. In addition, since the method described above may be applied only at least to a portion of the members constituting at least one of the systems for fluids, it is economical. Accordingly, radiation dose upon inspection of equipments and pipelines for fluids can be reduced simply and reliably. (I.S.)

  5. Pipelines in power plants

    International Nuclear Information System (INIS)

    Oude-Hengel, H.H.

    1978-01-01

    Since the end of the Sixties, steam-transporting pipelines are given great attention, as pipeline components often fail, partially even long before their designed operation time is over. Thus, experts must increasingly deal with questions of pipelines and their components. Design and calculation, production and operation of pipelines are included in the discussion. Within the frame of this discussion, planners, producers, operators, and technical surveillance personnel must be able to offer a homogenous 'plan for assuring the quality of pipelines' in fossil and nuclear power plants. This book tries to make a contribution to this topic. 'Quality assuring' means efforts made for meeting the demands of quality (reliability). The book does not intend to complete with well-known manuals, as for as a complete covering of the topic is concerned. A substantial part of its sections serves to show how quality assurance of pipelines can be at least partially obtained by surveillance measures beginning with the planning, covering the production, and finally accompanying the operation. There is hardly need to mention that the sort of planning, production, and operation has an important influence on the quality. This is why another part of the sections contain process aspects from the view of the planners, producers, and operators. (orig.) [de

  6. Nuclear power plants

    International Nuclear Information System (INIS)

    Kiyokawa, Teruyuki; Soman, Yoshindo.

    1985-01-01

    Purpose: To constitute a heat exchanger as one unit by integrating primary and secondary coolant circuits with secondary coolant circuit and steam circuit into a single primary circuit and steam circuit. Constitution: A nuclear power plant comprises a nuclear reactor vessel, primary coolant pipeways and a leakage detection system, in which a dual-pipe type heat exchanger is connected to the primary circuit pipeway. The heat conduction tube of the heat exchanger has a dual pipe structure, in which the inside of the inner tube is connected to the primary circuit pipeway, the outside of the outer tube is connected to steam circuit pipeway and a fluid channel is disposed between the inner and outer tubes and the fluid channel is connected to the inside of an expansion tank for intermediate heat medium. The leak detection system is disposed to the intermediate heat medium expansion tank. Sodium as the intermediate heat medium is introduced from the intermediate portion (between the inner and outer tubes) by way of inermediate heat medium pipeways to the intermediate heat medium expansion tank and, further, to the intermediate portion for recycling. (Kawakami, Y.)

  7. Underground nuclear power plant

    International Nuclear Information System (INIS)

    Takahashi, Hideo.

    1997-01-01

    In an underground-type nuclear power plant, groups of containing cavities comprising a plurality of containing cavities connected in series laterally by way of partition walls are disposed in parallel underground. Controlled communication tunnels for communicating the containing cavities belonging to a control region to each other, and non-controlled communication tunnels for communicating containing cavities belonging to a non-controlled area to each other are disposed underground. A controlled corridor tunnel and a non-controlled corridor tunnel extended so as to surround the containing cavity groups are disposed underground, and the containing cavities belonging to the controlled area are connected to the controlled corridor tunnel respectively, and the containing cavities belonging to the non-controlled area are connected to the non-controlled corridor tunnel respectively. The excavating amount of earth and sand upon construction can be reduced by disposing the containing cavity groups comprising a plurality of containing cavities connected in series laterally. The time and the cost for the construction can be reduced, and various excellent effects can be provided. (N.H.)

  8. Impact of financial environmental incentives in the potential of electric power generation on the sugar cane plants

    International Nuclear Information System (INIS)

    Pinto, Claudio Plaza; Walter, Arnaldo

    1999-01-01

    The aim of the work is to present the electric power generation from biomass and the economic potential from sugar cane plants in Brazil. Computerized electricity costs simulation are presented and several financial incentives and external market effects are considered. The results are also presented and criticized

  9. Fire protection requirements of the insurance industry and their impact on nuclear power plant design and construction

    International Nuclear Information System (INIS)

    Deitchman, J.V.; King, W.T. Jr.; Nashman, T.A.

    1976-01-01

    The insurance industry, with its wealth of knowledge and experience in the fire protection area and with preservation of its funds at stake, has always been heavily involved in the fire protection programs of nuclear power plants. Since it was concerned with property preservation in addition to nuclear safety, the insurance industry placed more detailed emphasis on fire protection requirements than did the nuclear regulatory bodies. Since the Browns Ferry fire, however, the insurance industry, the Nuclear Regulatory Commission, the Advisory Committee on Reactor Safeguards and the utilities themselves have re-examined their approaches to fire protection. A more coordinated approach seems to have emerged, which is based largely upon insurance industry specifications and guidelines. The paper briefly summarizes the fire protection requirements of the insurance industry as they apply to nuclear power plants. Some of the ways these requirements affect project planning, plant design, and construction timing are reviewed, as well as some of the more controversial fire protection areas

  10. Power plants and safety 1982

    International Nuclear Information System (INIS)

    1982-01-01

    The papers of this volume deal with the whole range of safety issues from planning and construction to the operation of power plants, and discuss also issues like availability and safety of power plants, protective clothes and their incommodating effect, alternatives for rendering hot-water generators safe and the safety philosophy in steam turbine engineering. (HAG) [de

  11. Thermodynamic optimization of power plants

    NARCIS (Netherlands)

    Haseli, Y.

    2011-01-01

    Thermodynamic Optimization of Power Plants aims to establish and illustrate comparative multi-criteria optimization of various models and configurations of power plants. It intends to show what optimization objectives one may define on the basis of the thermodynamic laws, and how they can be applied

  12. Owners of nuclear power plants

    International Nuclear Information System (INIS)

    Wood, R.S.

    1991-07-01

    This report indicates percentage ownership of commercial nuclear power plants by utility companies. The report includes all plants operating, under construction, docketed for NRC safety and environmental reviews, or under NRC antitrust review, but does not include those plants announced but not yet under review or those plants formally cancelled. Part 1 of the report lists plants alphabetically with their associated applicants or licensees and percentage ownership. Part 2 lists applicants or licensees alphabetically with their associated plants and percentage ownership. Part 1 also indicates which plants have received operating licenses (OLS)

  13. Nuclear power plant diagnostic system

    International Nuclear Information System (INIS)

    Prokop, K.; Volavy, J.

    1982-01-01

    Basic information is presented on diagnostic systems used at nuclear power plants with PWR reactors. They include systems used at the Novovoronezh nuclear power plant in the USSR, at the Nord power plant in the GDR, the system developed at the Hungarian VEIKI institute, the system used at the V-1 nuclear power plant at Jaslovske Bohunice in Czechoslovakia and systems of the Rockwell International company used in US nuclear power plants. These diagnostic systems are basically founded on monitoring vibrations and noise, loose parts, pressure pulsations, neutron noise, coolant leaks and acoustic emissions. The Rockwell International system represents a complex unit whose advantage is the on-line evaluation of signals which gives certain instructions for the given situation directly to the operator. The other described systems process signals using similar methods. Digitized signals only serve off-line computer analyses. (Z.M.)

  14. VGB Congress 'Power Plants 2006'

    International Nuclear Information System (INIS)

    Anon.

    2006-01-01

    The VGB Congress 'Power Plants' took place in Dresden, 27 th to 29 th September 2006 under the auspices of the Federal Minister for Economics and Technology, Michael Glos. The motto of this year's Congress was 'Future becomes Reality - Investments in New Power Plants'. More than 1,200 participants from Germany and abroad attended the plenary and technical lectures on the topics 'Market and Competition' as well as 'Technology, Operation and Environment' for information and discussion. Special papers were dealing with further issues like 'Generation Market in Europe', 'Clean Power Technology Platform', French policy for new power plants as well as potentials and technology of renewables. (orig.)

  15. Nuclear power plant V-1

    International Nuclear Information System (INIS)

    1998-01-01

    The nuclear power plant Bohunice V -1 is briefly described. This NPP consists from two reactor units. Their main time characteristics are (Reactor Unit 1, Reactor Unit 2): beginning of construction - 24 April 1972; first controlled reactor power - 27 November 1978, 15 March 1980; connection to the grid - 17 December 1978, 26 March 1980; commercial operation - 1 April 1980, 7 January 1981. This leaflet contains: NPP V-1 construction; Major technological equipment (Primary circuit: Nuclear reactor [WWER 440 V230 type reactor];Steam generator; Reactor Coolant Pumps; Primary Circuit Auxiliary Systems. Secondary circuit: Turbine generators, Nuclear power plant electrical equipment; power plant control) and technical data

  16. Emergency power systems at nuclear power plants

    International Nuclear Information System (INIS)

    1982-01-01

    This Guide applies to nuclear power plants for which the total power supply comprises normal power supply (which is electric) and emergency power supply (which may be electric or a combination of electric and non-electric). In its present form the Guide provides general guidance for all types of emergency power systems (EPS) - electric and non-electric, and specific guidance (see Appendix A) on the design principles and the features of the emergency electric power system (EEPS). Future editions will include a second appendix giving specific guidance on non-electric power systems. Section 3 of this Safety Guide covers information on considerations that should be taken into account relative to the electric grid, the transmission lines, the on-site electrical supply system, and other alternative power sources, in order to provide high overall reliability of the power supply to the EPS. Since the nuclear power plant operator does not usually control off-site facilities, the discussion of methods of improving off-site reliability does not include requirements for facilities not under the operator's control. Sections 4 to 11 of this Guide provide information, recommendations and requirements that would apply to any emergency power system, be it electric or non-electric

  17. Radiochemistry in nuclear power plants

    International Nuclear Information System (INIS)

    Schwarz, W.

    2007-01-01

    Radiochemistry is employed in nuclear power plants not as an end in itself but, among other things, as a main prerequisite of optimum radiation protection. Radiochemical monitoring of various loops provides important information about sources of radioactivity, activity distribution in the plant and its changes. In the light of these analytical findings, plant crews are able to take measures having a positive effect on radiation levels in the plant. The example of a BWR plant is used to show, among other things, how radiochemical analyses helped to reduce radiation levels in a plant and, as a consequence, to decrease clearly radiation exposure of the personnel despite higher workloads. (orig.)

  18. Power plants operating in normal conditions, space management, and environment

    International Nuclear Information System (INIS)

    Bertron, L.

    1986-01-01

    This paper presents the local populations considerations related to the establishment of a nuclear power plant comprising 4 units of 900 MW: reception of a population in the existing environment, acceptance of the power plant by the local population, effluent releases and environmental impacts, and the power plant future [fr

  19. Nuclear power plant annunciator systems

    International Nuclear Information System (INIS)

    Rankin, W.L.

    1983-08-01

    Analyses of nuclear power plant annunciator systems have uncovered a variety of problems. Many of these problems stem from the fact that the underlying philosophy of annunciator systems have never been elucidated so as to impact the initial annunciator system design. This research determined that the basic philosophy of an annunciator system should be to minimize the potential for system and process deviations to develop into significant hazards. In order to do this the annunciator system should alert the operators to the fact that a system or process deviation exists, inform the operators as to the priority and nature of the deviation, guide the operators' initial responses to the deviation, and confirm whether operators responses corrected the deviation. Annunciator design features were analyzed to determine to what degree they helped the system meet the functional criteria, the priority for implementing specific design features, and the cost and ease of implementing specific design features

  20. Problems of nuclear power plant safety evaluation

    International Nuclear Information System (INIS)

    Suchomel, J.

    1977-01-01

    Nuclear power plant safety is discussed with regard to external effects on the containment and to the human factor. As for external effects, attention is focused on shock waves which may be due to explosions or accidents in flammable material transport and storage, to missiles, and to earthquake effects. The criteria for evaluating nuclear power plant safety in different countries are shown. Factors are discussed affecting the reliability of man with regard to his behaviour in a loss-of-coolant accident in the power plant. Different types of PWR containments and their functions are analyzed, mainly in case of accident. Views are discussed on the role of destructive accidents in the overall evaluation of fast reactor safety. Experiences are summed up gained with the operation of WWER reactors with respect to the environmental impact of the nuclear power plants. (Z.M.)

  1. Millstone nuclear power plant emergency system assessment

    International Nuclear Information System (INIS)

    Akhmad Khusyairi

    2011-01-01

    U.S.NRC determined an obligation to build a nuclear power plant emergency response organization for both on-site and off-site. Millstone Nuclear Power Plants have 3 nuclear reactors and 2 of 3 still in commercial operation. Reactor unit 1, BWR type has been permanently shut down in 1998, while the two others, units 2 and 3 obtain the extended operating license respectively until 2035 and 2045. As a nuclear installation has the high potential radiological impact, Millstone nuclear power plant emergency response organization must establish both on-site or off-site. Emergency response organization that is formed must involve several state agencies, both state agencies and municipality. They have specific duties and functions in a state of emergency, so that protective measures can be undertaken in accordance with the community that has been planned. Meanwhile, NRC conduct their own independent assessment of nuclear power plant emergencies. (author)

  2. The Impact of the Bituminous Coal Combustion from the Thermoelectric Power Plant from Paroseni on the Environment of Jiu Valley

    Directory of Open Access Journals (Sweden)

    Mircea Rebrisoreanu

    2002-04-01

    Full Text Available The Jiu Valley Basin is one of the most important coal mining areas in Romania. Other industries, including a power plant, are also well developed in this area. Therefore, pollution is very high. One of the most polluted environmental compounds is the air. High mountains surround the Jiu Valley, which makes difficult the air refreshing. For this reason, it is very important to discuss the air pollution and especially that produced by dust. Since the industrial companies are concentrated in a small area, it is very difficult to identify and prosecute the polluting one. The present paper aims to identify the sources of air pollution, especially among the mining companies, because the power plant is considered the most important polluting agent in this area.

  3. Next Generation Geothermal Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Brugman, John; Hattar, Mai; Nichols, Kenneth; Esaki, Yuri

    1995-09-01

    A number of current and prospective power plant concepts were investigated to evaluate their potential to serve as the basis of the next generation geothermal power plant (NGGPP). The NGGPP has been envisaged as a power plant that would be more cost competitive (than current geothermal power plants) with fossil fuel power plants, would efficiently use resources and mitigate the risk of reservoir under-performance, and minimize or eliminate emission of pollutants and consumption of surface and ground water. Power plant concepts were analyzed using resource characteristics at ten different geothermal sites located in the western United States. Concepts were developed into viable power plant processes, capital costs were estimated and levelized busbar costs determined. Thus, the study results should be considered as useful indicators of the commercial viability of the various power plants concepts that were investigated. Broadly, the different power plant concepts that were analyzed in this study fall into the following categories: commercial binary and flash plants, advanced binary plants, advanced flash plants, flash/binary hybrid plants, and fossil/geothed hybrid plants. Commercial binary plants were evaluated using commercial isobutane as a working fluid; both air-cooling and water-cooling were considered. Advanced binary concepts included cycles using synchronous turbine-generators, cycles with metastable expansion, and cycles utilizing mixtures as working fluids. Dual flash steam plants were used as the model for the commercial flash cycle. The following advanced flash concepts were examined: dual flash with rotary separator turbine, dual flash with steam reheater, dual flash with hot water turbine, and subatmospheric flash. Both dual flash and binary cycles were combined with other cycles to develop a number of hybrid cycles: dual flash binary bottoming cycle, dual flash backpressure turbine binary cycle, dual flash gas turbine cycle, and binary gas turbine

  4. Fish impingement at Lake Michigan power plants

    International Nuclear Information System (INIS)

    Sharma, R.K.; Freeman, R.F.; Spigarelli, S.A.

    1976-01-01

    A study was initiated in 1974 to survey the magnitude and to evaluate the impact of fish impingement at 20 power plants on the Great Lakes. Data on impingement rates, site characteristics, intake designs and operational features have been collected and analyzed. Interpretive analyses of these data are in progress. The objectives of this study were: to summarize fish impingement data for Lake Michigan (16/20 plants surveyed are on Lake Michigan); to assess the significance of total and source-related mortalities on populations of forage and predator species; and to expand the assessment of power plant impingement to include all water intakes on Lake Michigan. Data are tabulated

  5. Electricity generation of Maritsa-Iztok coal-fired power plant in Bulgaria and its complex impact on the environment

    International Nuclear Information System (INIS)

    Mitrikov, M.; Antonov, A.; Hristov, Hr.

    2001-01-01

    Soil, water and vegetable samples from the region of Maritsa-Iztok Coal-Fired Power Plants (CFPP) in Bulgaria have been studied using a large variety of methods for analysis: γ- and neutron activation analysis, γ-spectrometry, radiometry, mass- spectrometry, physicochemical analysis, soil sciences study. Detailed information about the concentration of ecologically important elements in the chain coal bottom ash, fly ashes environment (soil, water, air, vegetation) has been obtained, allowing to estimate the present ecological state of the region. (author)

  6. The Impact of the Bituminous Coal Combustion from the Thermoelectric Power Plant from Paroseni on the Environment of Jiu Valley

    OpenAIRE

    Mircea Rebrisoreanu; Eugen Traistă; Aronel Matei; Ovidiu Barbu; Vlad A. Codrea

    2002-01-01

    The Jiu Valley Basin is one of the most important coal mining areas in Romania. Other industries, including a power plant, are also well developed in this area. Therefore, pollution is very high. One of the most polluted environmental compounds is the air. High mountains surround the Jiu Valley, which makes difficult the air refreshing. For this reason, it is very important to discuss the air pollution and especially that produced by dust. Since the industrial companies are concentrated in a ...

  7. Materials availability for fusion power plant construction

    International Nuclear Information System (INIS)

    Hartley, J.N.; Erickson, L.E.; Engel, R.L.; Foley, T.J.

    1976-09-01

    A preliminary assessment was made of the estimated total U.S. material usage with and without fusion power plants as well as the U.S. and foreign reserves and resources, and U.S. production capacity. The potential environmental impacts of fusion power plant material procurement were also reviewed including land alteration and resultant chemical releases. To provide a general measure for the impact of material procurement for fusion reactors, land requirements were estimated for mining and disposing of waste from mining

  8. Automation technology in power plants

    International Nuclear Information System (INIS)

    Essen, E.R.

    1995-01-01

    In this article a summery of the current architecture of modern process control systems in power plants and future trends have been explained. The further development of process control systems for power plants is influenced both by the developments in component and software technologies as well as the increased requirements of the power plants. The convenient and low cost configuration facilities of new process control systems have now reached a significance which makes it easy for customers to decide to purchase. (A.B.)

  9. Man and nuclear power plants

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    According to the Inst. fuer Unfallforschung/TUeV Rheinland, Koeln, the interpretation of empirical data gained from the operation of nuclear power plants at home and abroad during the period 1967-1975 has shown that about 38% of all reactor accidents were caused by human failures. These occured either during the design and construction, the commissioning, the reconditioning or the operation of the plants. This very fact stresses human responsibility for the safety of nuclear power plants, in spite of those plants being automated to a high degree and devices. (orig.) [de

  10. Owners of nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Hudson, C.R.; White, V.S.

    1996-11-01

    Commercial nuclear power plants in this country can be owned by a number of separate entities, each with varying ownership proportions. Each of these owners may, in turn, have a parent/subsidiary relationship to other companies. In addition, the operator of the plant may be a different entity as well. This report provides a compilation on the owners/operators for all commercial power reactors in the United States. While the utility industry is currently experiencing changes in organizational structure which may affect nuclear plant ownership, the data in this report is current as of July 1996. The report is divided into sections representing different aspects of nuclear plant ownership.

  11. Owners of nuclear power plants

    International Nuclear Information System (INIS)

    Wood, R.S.

    1979-12-01

    The following list indicates percentage ownership of commercial nuclear power plants by utility companies as of December 1, 1979. The list includes all plants licensed to operate, under construction, docketed for NRC safety and envionmental reviews, or under NRC antitrust review. It does not include those plants announced but not yet under review or those plants formally cancelled. In many cases, ownership may be in the process of changing as a result of antitrust license conditions and hearings, altered financial conditions, changed power needs, and other reasons. However, this list reflects only those ownership percentages of which the NRC has been formally notified

  12. Mitigation of socio-economic impacts due to the construction of energy projects in rural communities: an evaluation of the Hartsville nuclear power plant transportation-mitigation program

    International Nuclear Information System (INIS)

    Whitney, T.C.

    1982-01-01

    This study analyzes the effects of a commuter ride-sharing program in mitigating the harmful socio-economic impacts of a short-term, labor-intensive nuclear-power-plant construction project. The major hypothesis is that transportation-mitigation programs are more cost-effective in reducing the undesirable socio-economic impacts of large-scale construction projects than programs designed to mitigate impacts through the provision of public services for migrating workers. The dissertation begins by delineating the socio-economic effects of large-scale construction projects in rural areas. It proceeds to show how some of the deleterious impacts were mitigated using a commuter ride-sharing program. After the range of potential socio-economic impacts was established, a framework was developed to evaluate the effects of the transportation-mitigation program in mediating the harmful impacts. The framework involved the integration of the cost-benefit technique with social-impact assessment. The evaluation was grounded in a comparative framework whereby the Hartsville project community was compared with a similar community undergoing the construction of a nuclear power plant but without a commuter ride-sharing program, and a community not experiencing a major construction project. The research findings indicated that the transportation-mitigation program substantially reduced the in-migration of construction workers into the Hartsville-Trousdale County area. Further, the program was cost effective, with a benefit-cost ratio of 2.5 and net benefits totalling 28 million dollars

  13. Competitive breeder power plants

    International Nuclear Information System (INIS)

    Winkleblack, R.K.

    1984-01-01

    To utilize the fissile material that is accumulating in the utilities' spent fuel pools, breeder plants must be less expensive than current LWR costs (or utilities will not buy nuclear plants in the near future) and also be highly reliable. The fundamental differences between LWRs and LMFBRs are discussed and recommendations are made for making the most of these differences to design a superior breeder plant that can sell in the future, opening the way to U.S. utilities becoming self-sufficient for fuel supply for centuries

  14. Maintenance of nuclear power plants

    International Nuclear Information System (INIS)

    Migaud, D.; Hutin, J.P.; Jouette, I.; Eymond, P.; Devie, P.; Cudelou, C.; Magnier, S.; Frydman, M.

    2016-01-01

    This document gathers different articles concerning the maintenance of the French nuclear power plants. The first article analyses the impact of the recent law on the energetic transition that sets the share of nuclear power at 50% of the electricity produced by 2025. A consequence may be the decommissioning of 17 to 20 reactors by 2025 and the huge maintenance program called 'Grand Carenage' whose aim is to extend operating life over 40 years will have to be re-considered in order to avoid useless expenses. The second article shows that in 2015 the French nuclear reactor fleet got very good results in terms of availability and safety. There were 49 scheduled outages and among them some ended ahead of time. The third article describes the specificities of the maintenance of a nuclear power plant, for instance the redundancy of some systems implies that maintenance has to deal with systems that have never functioned but must be ready to operate at any moment. Another specificity is the complexity of a nuclear power plant that implies an essential phase of preparation for maintenance operations. Because of safety requirements any maintenance operation has to be controlled, checked and may provide feedback. The fourth article presents the 'Grand Carenage' maintenance program that involves the following operations: the replacement of steam generators, the re-tubing of condensers, the replacement of the filtering drums used for cooling water, the testing of the reactor building, the hydraulic test of the primary circuit and the inspection of the reactor vessel. The fifth article focuses on the organization of the work-site for maintenance operations and the example of the Belleville-sur-Loire is described in the sixth article. Important maintenance operations like 'Grand Carenage' requires a strong collaboration with a network of specialized enterprises and as no reactor (except Flamanville EPR) is being built in France, maintenance

  15. Space nuclear reactor power plants

    International Nuclear Information System (INIS)

    Buden, D.; Ranken, W.A.; Koenig, D.R.

    1980-01-01

    Requirements for electrical and propulsion power for space are expected to increase dramatically in the 1980s. Nuclear power is probably the only source for some deep space missions and a major competitor for many orbital missions, especially those at geosynchronous orbit. Because of the potential requirements, a technology program on space nuclear power plant components has been initiated by the Department of Energy. The missions that are foreseen, the current power plant concept, the technology program plan, and early key results are described

  16. Nuclear power plant operator licensing

    International Nuclear Information System (INIS)

    1997-01-01

    The guide applies to the nuclear power plant operator licensing procedure referred to the section 128 of the Finnish Nuclear Energy Degree. The licensing procedure applies to shift supervisors and those operators of the shift teams of nuclear power plant units who manipulate the controls of nuclear power plants systems in the main control room. The qualification requirements presented in the guide also apply to nuclear safety engineers who work in the main control room and provide support to the shift supervisors, operation engineers who are the immediate superiors of shift supervisors, heads of the operational planning units and simulator instructors. The operator licensing procedure for other nuclear facilities are decided case by case. The requirements for the basic education, work experience and the initial, refresher and complementary training of nuclear power plant operating personnel are presented in the YVL guide 1.7. (2 refs.)

  17. Nuclear Power Plant Simulation Game.

    Science.gov (United States)

    Weiss, Fran

    1979-01-01

    Presents a nuclear power plant simulation game which is designed to involve a class of 30 junior or senior high school students. Scientific, ecological, and social issues covered in the game are also presented. (HM)

  18. Elecnuc. Nuclear power plants worldwide

    International Nuclear Information System (INIS)

    1998-01-01

    This small folder presents a digest of some useful information concerning the nuclear power plants worldwide and the situation of nuclear industry at the end of 1997: power production of nuclear origin, distribution of reactor types, number of installed units, evolution and prediction of reactor orders, connections to the grid and decommissioning, worldwide development of nuclear power, evolution of power production of nuclear origin, the installed power per reactor type, market shares and exports of the main nuclear engineering companies, power plants constructions and orders situation, evolution of reactors performances during the last 10 years, know-how and development of nuclear safety, the remarkable facts of 1997, the future of nuclear power and the energy policy trends. (J.S.)

  19. Robotics for nuclear power plants

    International Nuclear Information System (INIS)

    Shiraiwa, Takanori; Watanabe, Atsuo; Miyasawa, Tatsuo

    1984-01-01

    Demand for robots in nuclear power plants is increasing of late in order to reduce workers' exposure to radiations. Especially, owing to the progress of microelectronics and robotics, earnest desire is growing for the advent of intellecturized robots that perform indeterminate and complicated security work. Herein represented are the robots recently developed for nuclear power plants and the review of the present status of robotics. (author)

  20. Robotics for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Shiraiwa, Takanori; Watanabe, Atsuo; Miyasawa, Tatsuo

    1984-10-01

    Demand for robots in nuclear power plants is increasing of late in order to reduce workers' exposure to radiations. Especially, owing to the progress of microelectronics and robotics, earnest desire is growing for the advent of intellecturized robots that perform indeterminate and complicated security work. Herein represented are the robots recently developed for nuclear power plants and the review of the present status of robotics.

  1. Decommissioning of nuclear power plants

    International Nuclear Information System (INIS)

    Vollradt, J.

    1977-01-01

    A survey of the main questions of decommissioning of nuclear power plants will be given in the sight of German utilities (VDEW-Working group 'Stillegung'). The main topics are: 1) Definitions of decommissioning, entombment, removal and combinations of such alternatives; 2) Radioactive inventory (build up and decay); 3) Experience up to now; 4) Possibilities to dismantle are given by possibility to repair nuclear power plants; 5) Estimated costs, waste, occupational radiation dose; 6) German concept of decommissioning. (orig./HK) [de

  2. PV power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-01

    Within the international seminar of the Ostbayerisches Technologie-Transfer-Institut e.V. (OTTI) at 11th June, 2012 in Munich (Federal Republic of Germany), the following lectures were held: (1) Technical due diligence (Dietmar Obst); (2) Certification / rating system for large PV plants (Robert Pfatischer); (3) O and M requirements (Lars Rulf); (4) IR photography for large scale systems (Bernhard Weinreich); (5) New market models for PV systems - direct marketing and sales of PV electricity (Martin Schneider); (6) Needs and benefits for plant certification for grid connection and operation (Christoph Luetke-Lengerich); (7) Lare volume module testing / Screening in the field and workshop (Semir Merzoug); (8) Dismantling costs of large scale PV plants (Siegfried Schimpf).

  3. Inertial fusion commercial power plants

    International Nuclear Information System (INIS)

    Logan, B.G.

    1994-01-01

    This presentation discusses the motivation for inertial fusion energy, a brief synopsis of five recently-completed inertial fusion power plant designs, some general conclusions drawn from these studies, and an example of an IFE hydrogen synfuel plant to suggest that future fusion studies consider broadening fusion use to low-emission fuels production as well as electricity

  4. Using the Community Multiscale Air Quality (CMAQ) model to estimate public health impacts of PM2.5 from individual power plants.

    Science.gov (United States)

    Buonocore, Jonathan J; Dong, Xinyi; Spengler, John D; Fu, Joshua S; Levy, Jonathan I

    2014-07-01

    We estimated PM2.5-related public health impacts/ton emitted of primary PM2.5, SO2, and NOx for a set of power plants in the Mid-Atlantic and Lower Great Lakes regions of the United States, selected to include varying emission profiles and broad geographic representation. We then developed a regression model explaining variability in impacts per ton emitted using the population distributions around each plant. We linked outputs from the Community Multiscale Air Quality (CMAQ) model v 4.7.1 with census data and concentration-response functions for PM2.5-related mortality, and monetized health estimates using the value-of-statistical-life. The median impacts for the final set of plants were $130,000/ton for primary PM2.5 (range: $22,000-230,000), $28,000/ton for SO2 (range: $19,000-33,000), and $16,000/ton for NOx (range: $7100-26,000). Impacts of NOx were a median of 34% (range: 20%-75%) from ammonium nitrate and 66% (range: 25%-79%) from ammonium sulfate. The latter pathway is likely from NOx enhancing atmospheric oxidative capacity and amplifying sulfate formation, and is often excluded. Our regression models explained most of the variation in impact/ton estimates using basic population covariates, and can aid in estimating impacts averted from interventions such as pollution controls, alternative energy installations, or demand-side management. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Emergency power systems at nuclear power plants

    International Nuclear Information System (INIS)

    1991-01-01

    This Safety Guide was prepared as part of the Nuclear Safety Standards programme for establishing Codes and Safety Guides relating to nuclear power plants (NPPs). The first edition of the present Safety Guide was developed in the early 1980s. The text has now been brought up-to-date, refined in several details and amended to include non-electrical diverse and independent power sources. This Guide applies to NPP for which the total power supply comprises a normal power supply and an emergency power supply (EPS), which may be electrical or a combination of electrical and non-electrical. The Guide provides general guidance for all types of EPS and specific guidance on the design safety requirements and the features of the electrical and non-electrical portions of the EPS. 9 figs, 2 tabs

  6. The issue of the fourth nuclear power plant and its impact on 3-E problems in Taiwan - empirical evidence from the energy forecasting (EnFore) system

    International Nuclear Information System (INIS)

    Bor, Y.J.; Chou, F.-Y.

    2003-01-01

    Taiwan has placed considerable emphasis on economic, energy and environmental (3-E) problems in recent decades. Following President Chen's inauguration, one particular issue of concern has been the current dispute over the fourth nuclear power plant (FNPP) in northern Taiwan. This dispute has had a serious impact on Taiwan's economy, including its energy structure and general policy towards CO 2 emission controls. It is estimated, for example, that the loss to Taiwan's capital market as a result of the FNPP dispute, reached NT$7 trillion (about US$219 billion) by the end of 2000. If Taiwan Power Company (Taipower) were to replace the nuclear power plant capacity with liquified natural gas generators, average utility prices would go up by around 4.6% over the next 10 years. The alternative would be for low-cost coal-fired power plants to assume the major position in future power generation; however, this could cause significant damage to Taiwan's CO 2 emission control policy. This paper uses an integrated computerized system model of energy forecasting to simulate the complex interrelationship between the various issues. Empirical results reveal that there are no perfect solutions available; thus, this is an important learning process for the government in terms of administration, as well as for other academic studies

  7. Organization patterns of PWR power plants

    International Nuclear Information System (INIS)

    Leicman, J.

    1980-01-01

    Organization patterns are shown for the St. Lucia 1, North Anna, Sequoyah, and Beaver Valley nuclear power plants, for a typical PWR power plant in the USA, for the Biblis/RWE-KWU nuclear power plants and for a four-unit nuclear power plant operated by Electricite de France as well as for the Loviisa power plant. Organization patterns are also shown for relatively independent and non-independent nuclear power plants according to IAEA recommendations. (J.P.)

  8. Low-power wind plants

    International Nuclear Information System (INIS)

    Kovalenko, V.I.; Shevchenko, Yu.V.; Shikhajlov, N.A.; Kokhanevich, V.P.; Tanan, G.L.

    1993-01-01

    Design peculiarities, as well as the prospects of development and introduction of the low-power (from 0.5 up to 4 kW) wind power plants (WPP) are considered. The variants of WPP with vertical and horizontal rotation axis are described. The data characterizing cost and structure of expenditures on WPP manufacture and operation are given

  9. Energy sources and power plants

    International Nuclear Information System (INIS)

    Schulz, Detlef; Schulz, Karen

    2013-01-01

    Energy is obtained from various energy sources (coal, petroleum, natural gas, nuclear fuels, wind energy, solar energy, hydro power, biomass, geothermal energy). These differ in each case with respect to their availability, methods of their production and the required power plant technologies. As technologies of the future fuel cells and nuclear fusion are traded. [de

  10. Pilot program to identify valve failures which impact the safety and operation of light water nuclear power plants

    International Nuclear Information System (INIS)

    Tsacoyeanes, J.C.; Raju, P.P.

    1980-04-01

    The pilot program described has been initiated under the Department of Energy Light Water Reactor Safety Research and Development Program and has the following specific objectives: to identify the principal types and causes of failures in valves, valve operators and their controls and associated hardware, which lead to, or could lead to plant trip; and to suggest possible remedies for the prevention of these failures and recommend future research and development programs which could lead to minimizing these valve failures or mitigating their effect on plant operation. The data surveyed cover incidents reported over the six-year period, beginning 1973 through the end of 1978. Three sources of information on valve failures have been consulted: failure data centers, participating organizations in the nuclear power industry, and technical documents

  11. Space power plants

    Science.gov (United States)

    Khudyakov, S. A.

    1985-05-01

    Power generators in space are examined. A semiconducting photoelectric converter (FEP) which converts the energy of solar radiation directly into electrical energy is discussed. The operating principle of an FEP is based on the interaction of solar light with a crystal semiconductor, in the process of which the photons produce free electrons, carriers of an electrical charge, in the crystal. Areas with a strong electrical field created specially under the effect of the p-n junction trap the freed electrons and divide them in such a fashion that a current and corresponding electrical power appear in the load circuit. The absorption of light in metals and pure semiconductors is outlined.

  12. A study on the assessment of safety culture impacts on risk of nuclear power plants using common uncertainty source model

    International Nuclear Information System (INIS)

    Lee, Yong Suk; Bang, Young Suk; Chung, Chang Hyun; Jeong, Ji Hwan

    2004-01-01

    Since International Safety Advisory Group (INSAG) introduced term 'safety culture', it has been widely recognized that safety culture has an important role in safety of nuclear power plants. Research on the safety culture can be divided in the following two parts. 1) Assessment of safety culture (by interview, questionnaire, etc.) 2) Assessment of link between safety culture and safety of nuclear power plants. There is a substantial body of literature that addresses the first part, but there is much less work that addresses the second part. To address the second part, most work focused on the development of model incorporating safety culture into Probabilistic Safety Assessment (PSA). One of the most advanced methodology in the area of incorporating safety culture quantitatively into PSA is System Dynamics (SD) model developed by Kwak et al. It can show interactions among various factors which affect employees' productivity and job quality. Also various situations in nuclear power plant can be simulated and time-dependent risk can be recalculated with this model. But this model does not consider minimal cut set (MCS) dependency and uncertainty of risk. Another well-known methodology is Work Process Analysis Model (WPAM) developed by Davoudian. It considers MCS dependency by modifying conditional probability values using SLI methodology. But we found that the modified conditional probability values in WPAM are somewhat artificial and have no sound basis. WPAM tend to overestimate conditional probability of hardware failure, because it uses SLI methodology which is normally used in Human Reliability Analysis (HRA). WPAM also does not consider uncertainty of risk. In this study, we proposed methodology to incorporate safety culture into PSA quantitatively that can deal with MCS dependency and uncertainty of risk by applying the Common Uncertainty Source (CUS) model developed by Zhang. CUS is uncertainty source that is common to basic events, and this can be physical

  13. Fatigue assessments in operating nuclear power plants

    International Nuclear Information System (INIS)

    Gosselin, S.R.; Deardorff, A.F.; Peltola, D.W.

    1994-01-01

    In November 1991, the ASME Section XI Task Group on Operating Plant Fatigue Assessment was formed to develop criteria and evaluation methodology for evaluating the effects of cyclic operation in operating nuclear power plants. The objective was to develop guidelines for inclusion in Section XI that could be used by plant operators in evaluating fatigue concerns and their impact on serviceability. This paper discusses the work performed by the Task Group. It explores the concept of ''Fatigue Design Basis'' versus ''Fatigue Operating Basis'' by examining the roles of ASME Section III and ASME Section XI in the design and operation of the nuclear power plants. Guidelines are summarized that may help plant operators perform effective design transient cycle evaluations and optimize cycle counting and fatigue usage tracking. The alternative fatigue evaluation approach using flaw tolerance is also introduced

  14. Monitoring Biological Activity at Geothermal Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Peter Pryfogle

    2005-09-01

    The economic impact of microbial growth in geothermal power plants has been estimated to be as high as $500,000 annually for a 100 MWe plant. Many methods are available to monitor biological activity at these facilities; however, very few plants have any on-line monitoring program in place. Metal coupon, selective culturing (MPN), total organic carbon (TOC), adenosine triphosphate (ATP), respirometry, phospholipid fatty acid (PLFA), and denaturing gradient gel electrophoresis (DGGE) characterizations have been conducted using water samples collected from geothermal plants located in California and Utah. In addition, the on-line performance of a commercial electrochemical monitor, the BIoGEORGE?, has been evaluated during extended deployments at geothermal facilities. This report provides a review of these techniques, presents data on their application from laboratory and field studies, and discusses their value in characterizing and monitoring biological activities at geothermal power plants.

  15. Evaluation of Radiological Impacts on the Operating Kartini Reactor and Natural Radioactivity of the Site Plan of Nuclear Power Plant Area

    International Nuclear Information System (INIS)

    Yazid, M; Sutresna, G; Sulistyono, A; Ngasifudin

    1996-01-01

    This radiological impacts evaluation covered of radioactivity in water, soil, grass, air samples and ambient gamma radiation that have been carried out in the Kartini reactor area and in the site plan of nuclear power plan are at Ujung Lemah Abang, Jepara, Central Java. The aim of this research was to determine that radiological impacts in the environment around the Kartini reactor compared to natural radioactivity for site plan of nuclear power plan area. The radioactivity in the water, soil and grass samples ware measured by low background beta counting system and were identified by low background gamma spectrometer. The radioactivity in the air samples was measured by beta portable counting system and the ambient gamma radiation was measured by portable high pressurized ionization chamber model RSS-112 Reuther-Stokes. The reactor data measurement was compared to the site plan of nuclear power plant area data for evaluation of radiological impacts on the operating reactor. From the evaluation and comparison can be concluded there are no indication of the radionuclide release from the reactor operation. The average radiactivity in the water, soil grass and air sample from the reactor area were between 0.17 - 0.61 Bq/1; 0,47 - 0,74 Bq/g; 4.43 - 4.60 Bq/g.ash and 49.53 - 70.90 x 10 Bq/cc. The average radioactivity of those sample from the nuclear power plant area were between 0.06-0.90 Bq/I; 0.02-0.86 Bq/g; 1.68-8.07 Bq/g.ash and 65.0-152.3 x 10 Bq/cc. The ambient gamma radiation were between 6.9-36.7 urad/h for the reactor area and 6.8-19.2 urad/h for the nuclear power plant area

  16. Evaluation of radiological impact of habitual atmospheric releases in the surroundings of the Juragua nuclear power plant

    International Nuclear Information System (INIS)

    Rodriguez Rodriguez, J.M.; Rosales, I.

    1993-01-01

    The considerations and fundamental data used to evaluate the individual doses to the population living within an area of 40 km in the surroundings of Juragua nuclear power plant are presented. Recognized dispersion models (Pasquill modified) and models of dose calculations due to continuous habitual air releases composed of gases and aerosols (47 radionuclides) are used for the calculations.The following ways are taken into account for evaluation: a)irradiation of the cloud, b)irradiation of contaminated ground, c)inhalation, d) ingestion of agro-products. The iso line maps of concentrations and fundamental doses for the site are shown

  17. Power plant simulation

    Energy Technology Data Exchange (ETDEWEB)

    Hacking, D [Marconi Simulation (United Kingdom)

    1992-09-01

    Over many years in the field of simulation Marconi has developed and adopted a number of procedures and methodologies for the management, design and development of an extensive range of training equipment. This equipment encompasses desktop computer-based training systems, generic training devices. The procurement of a training simulator is clearly dictated by the perceived training requirement or problem. Also, it should preferably involve or follow a detailed training needs analysis. Although the cost benefits of training are often difficult to quantify, a simulator is frequently easier to justify if plant familiarisation and training can be provided in advance of on-the-job experience. This is particularly true if the target operators have little hands-on experience of similar plant either in terms of processes or the operator interface. (author).

  18. Organizing nuclear power plant operation

    International Nuclear Information System (INIS)

    Adams, H.W.; Rekittke, K.

    1987-01-01

    With the preliminary culmination in the convoy plants of the high standard of engineered safeguards in German nuclear power plants developed over the past twenty years, the interest of operators has now increasingly turned to problems which had not been in the focus of attention before. One of these problems is the organization of nuclear power plant operation. In order to enlarge the basis of knowledge, which is documented also in the rules published by the Kerntechnischer Ausschuss (Nuclear Technology Committee), the German Federal Minister of the Interior has commissioned a study of the organizational structures of nuclear power plants. The findings of that study are covered in the article. Two representative nuclear power plants in the Federal Republic of Germany were selected for the study, one of them a single-unit plant run by an independent operating company in the form of a private company under German law (GmbH), the other a dual-unit plant operated as a dependent unit of a utility. The two enterprises have different structures of organization. (orig.) [de

  19. Atucha I nuclear power plant surveillance programme

    Energy Technology Data Exchange (ETDEWEB)

    Jinchuk, D [Comision Nacional de Energia Atomica, Buenos Aires (Argentina)

    1994-12-31

    After a review of the main characteristics of the Atucha I nuclear power plant and its pressure vessel, the embrittlement surveillance capsules and the irradiation conditions are described; Charpy impact tests and tensile tests were performed on the irradiated samples, and results are discussed and compared to theoretical calculations: transition temperature shifts, displacement per atom values. 6 refs., 16 figs., 7 tabs.

  20. MODELLING OF NUCLEAR POWER PLANT DECOMMISSIONING FINANCING

    Czech Academy of Sciences Publication Activity Database

    Bemš, J.; Knápek, J.; Králík, T.; Hejhal, M.; Kubančák, Ján; Vašíček, J.

    2015-01-01

    Roč. 164, č. 4 (2015), s. 519-522 ISSN 0144-8420 Institutional support: RVO:61389005 Keywords : nuclear power plant * methodology * future decommissioning costs Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.894, year: 2015

  1. Atucha I nuclear power plant surveillance programme

    International Nuclear Information System (INIS)

    Jinchuk, D.

    1993-01-01

    After a review of the main characteristics of the Atucha I nuclear power plant and its pressure vessel, the embrittlement surveillance capsules and the irradiation conditions are described; Charpy impact tests and tensile tests were performed on the irradiated samples, and results are discussed and compared to theoretical calculations: transition temperature shifts, displacement per atom values. 6 refs., 16 figs., 7 tabs

  2. TVA's nuclear power plant experience

    International Nuclear Information System (INIS)

    Willis, W.F.

    1979-01-01

    This paper reviews TVA's nuclear power plant design and construction experience in terms of schedule and capital costs. The completed plant in commercial operation at Browns Ferry and six additional plants currently under construction represent the nation's largest single commitment to nuclear power and an ultimate investment of $12 billion by 1986. The presentation is made in three separate phases. Phase one will recapitulate the status of the nuclear power industry in 1966 and set forth the assumptions used for estimating capital costs and projecting project schedules for the first TVA units. Phase two describes what happened to the program in the hectic early 1979's in terms of expansion of scope (particularly for safety features), the dramatic increase in regulatory requirements, vendor problems, stretchout of project schedules, and unprecedented inflation. Phase three addresses the assumptions used today in estimating schedules and plant costs for the next ten-year period

  3. Prospects for power plant technology

    International Nuclear Information System (INIS)

    Schilling, H.D.

    1993-01-01

    Careful conservation of resources in the enlarged context of the rational utilization of energy, the environment and capital will determine future power plant technology. The mainstays will be the further development of power plant concepts based on fossil (predominantly coal) and nuclear fuels; world-wide, also regenerative and CO 2 -free hydro-electric power will play a role. Rapid conversion of the available potential requires clear, long-term stable and reliable political framework conditions for the release of the necessary entrepreneurial forces. (orig.) [de

  4. Partner of nuclear power plants

    International Nuclear Information System (INIS)

    Gribi, M.; Lauer, F.; Pauli, W.; Ruzek, W.

    1992-01-01

    Sulzer, the Swiss technology group, is a supplier of components and systems for nuclear power plants. Important parts of Swiss nuclear power stations, such as containments, reactor pressure vessels, primary pipings, are made in Winterthur. Sulzer Thermtec AG and some divisions of Sulzer Innotec focus their activities on servicing and backfitting nuclear power plants. The European market enjoys priority. New types of valves or systems are developed as economic solutions meeting more stringent criteria imposed by public authorities or arising from operating conditions. (orig.) [de

  5. Nuclear power plant V-2

    International Nuclear Information System (INIS)

    1998-01-01

    The nuclear power plant Bohunice V -2 is briefly described. This NPP consists from two reactor units. Their main time characteristics are (Reactor Unit 1, Reactor Unit 2): beginning of construction - December 1976; first controlled reactor power - 7 August 1984, 2 August 1985; connection to the grid - 20 August 1984, 9 August 1985; commercial operation - 14 February 1985, 18 December 1985. This leaflet contains: NPP V-2 construction; Major technological equipment [WWER 440 V230 type reactor; Nuclear Power plant operation safety (Safety barriers; Safety systems [Active safety systems, Passive safety systems]); Centralized heat supply system; Scheme of Bohunice V-2 NPP and technical data

  6. Simulation technology for power plants

    International Nuclear Information System (INIS)

    Kuwabara, Kazuo; Yanai, Katsuya.

    1988-01-01

    In the simulation of nuclear power stations, there are the simulation for the training of plant operation, the plant simulation for analyzing the operation of an electric power system, the simulation for controlling a core, the simulation for the safety analysis of reactors, the simulation for the design analysis of plants and so on as the typical ones. The outline and the technical features of these simulations are described. With the increase of capacity and complexity of thermal power plants, recently the automation of operation has advanced rapidly. The chance of starting up and stopping plants by operators themselves is few, and the chance of actually experiencing troubles also is few as the reliability of plants improved. In order to maintain the ability of coping with plant abnormality, an operation supporting system is strongly demanded. Operation training simulators and used widely now, and there are the simulators for analysis, those of replica type, those of versatile compact type and so on. The system configuration, modeling techniques, training function and others of the replica type are explained. In hydroelectric plants, the behavior of water in penstocks, the characteristics of water turbines, the speed control system for water turbines and the characteristics of generators become the main subjects of simulation. These are described. (Kako, I.)

  7. ALARA at nuclear power plants

    International Nuclear Information System (INIS)

    Baum, J.W.

    1991-01-01

    Implementation of the ALARA principle at nuclear power plants presents a continuing challenge for health physicists at utility corporate and plant levels, for plant designers, and for regulatory agencies. The relatively large collective doses at some plants are being addressed through a variety of dose reduction techniques. Initiatives by the ICRP, NCRP, NRC, INPO, EPRI, and BNL ALARA Center have all contributed to a heightened interest and emphasis on dose reduction. The NCRP has formed Scientific Committee 46-9 which is developing a report on ALARA at Nuclear Power Plants. It is planned that this report will include material on historical aspects, management, valuation of dose reduction ($/person-Sv), quantitative and qualitative aspects of optimization, design, operational considerations, and training. The status of this work is summarized in this report

  8. Modifications to nuclear power plants. Safety guide

    International Nuclear Information System (INIS)

    2004-01-01

    This Safety Guide was prepared under the IAEA's programme for safety standards for nuclear power plants. It supplements Section 7 of the Safety Requirements publication on Safety of Nuclear Power Plants: Operation, which establishes the safety requirements for the modification of nuclear power plants. Reasons for carrying out modifications to nuclear power plants may include: (1) maintaining or strengthening existing safety provisions and thus maintaining consistency with or improving on the current design. (2) recovering from plant faults. (3) improving the thermal performance or increasing the power rating of the plant. (4) increasing the maintainability of the plant, reducing the radiation exposure of personnel or reducing the costs of plant maintenance. And (5) extending the design life of the plant. Most modifications, made on the basis of operating experience, are intended to improve on the design or to improve operational performance and flexibility. Some are rendered necessary by new regulatory requirements, ageing of the plant or obsolescence of equipment. However, the benefits of regularly updating the plant design can be jeopardized if modifications are not kept under rigorous control throughout the lifetime of the plant. The need to reduce costs and improve efficiency, in combination with changes to the structure of the electricity generation sector of the economy in many countries, has led many companies to make changes in the structure of the operating organization for nuclear power plants. Whatever the reason for such organizational changes, consideration should be given to the effects of those changes with the aim of ensuring that they would have no impacts that would compromise the safety of the plant. The objective of this Safety Guide is to provide guidance and recommendations on controlling activities relating to modifications at nuclear power plants in order to reduce risk and to ensure that the configuration of the plant is at all times under

  9. Modifications to nuclear power plants. Safety guide

    International Nuclear Information System (INIS)

    2007-01-01

    This Safety Guide was prepared under the IAEA's programme for safety standards for nuclear power plants. It supplements Section 7 of the Safety Requirements publication on Safety of Nuclear Power Plants: Operation, which establishes the safety requirements for the modification of nuclear power plants. Reasons for carrying out modifications to nuclear power plants may include: (1) maintaining or strengthening existing safety provisions and thus maintaining consistency with or improving on the current design. (2) recovering from plant faults. (3) improving the thermal performance or increasing the power rating of the plant. (4) increasing the maintainability of the plant, reducing the radiation exposure of personnel or reducing the costs of plant maintenance. And (5) extending the design life of the plant. Most modifications, made on the basis of operating experience, are intended to improve on the design or to improve operational performance and flexibility. Some are rendered necessary by new regulatory requirements, ageing of the plant or obsolescence of equipment. However, the benefits of regularly updating the plant design can be jeopardized if modifications are not kept under rigorous control throughout the lifetime of the plant. The need to reduce costs and improve efficiency, in combination with changes to the structure of the electricity generation sector of the economy in many countries, has led many companies to make changes in the structure of the operating organization for nuclear power plants. Whatever the reason for such organizational changes, consideration should be given to the effects of those changes with the aim of ensuring that they would have no impacts that would compromise the safety of the plant. The objective of this Safety Guide is to provide guidance and recommendations on controlling activities relating to modifications at nuclear power plants in order to reduce risk and to ensure that the configuration of the plant is at all times under

  10. Environmental Impact Report from Santa Rita Hydroelectric Power Plant (Minas Gerais State - Brazil): technical strategic for its elaboration; Relatorio de Impacto Ambiental da Usina Hidreletrica da Santa Rita (MG): estrategica tecnica para sua elaboracao

    Energy Technology Data Exchange (ETDEWEB)

    Souza, J.A. de; Marques Neto, F P [Companhia Energetica de Minas Gerais (CEMIG), Belo Horizonte, MG (Brazil)

    1990-12-31

    The steps for developing the technical strategies used on the elaboration of Environmental Impact Report from Santa Rita Hydroelectric Power Plant, Minas Gerais State, are described, including the influence area, technical requirements, impact identification, technical selection of mitigative measures, impact meaning and strategy for evaluating the identified impacts. (C.G.C.).

  11. Slovak power stations, Nuclear Power Plants Mochovce (Annual report 1997)

    International Nuclear Information System (INIS)

    1998-01-01

    A brief account of activities carried out by the Nuclear power plants Mochovce in 1997 is presented. These activities are reported under the headings: (1) Director's foreword; (2) Power plant management; (3) Highlights of 1997; (4) Capital construction; (5) Nuclear safety; (6) Radiation safety; (7) Work safety and health protection at work; (9) Fire protection; (10) Units upgrading - safety measures; (11) Maintenance; (12) Operation; (13) Environmental impacts of operations; (14) List of balances; (15) Human sources; (16) International co-operation; (17) Public relations

  12. Ocean power plants

    Energy Technology Data Exchange (ETDEWEB)

    Mazurkiedicz, B.; Sliwa, B.

    1982-01-01

    Plans are examined for OTES of close and open cycles. Examples of design of TO are presented. Main design elements of the OTES are indicated and their arrangement. The OTES can be realized even now with comparatively small capital investments. Searches are made for solutions which would make it possible to construct the OTES and not in tropical regions, i.e., with very small temperature differences. The studies indicated that with a difference of temperatures 4.5/sup 0/C and temperature of the thermal water 5.5/sup 0/C, it is possible to build OTES with power 100 MW. With difference in temperature 5/sup 0/C, the power will reach 130 MW.

  13. Submarine nuclear power plant

    International Nuclear Information System (INIS)

    Enohara, Masami; Araragi, Fujio.

    1980-01-01

    Purpose: To provide a ballast tank, and nuclear power facilities within the containment shell of a pressure resistance structure and a maintenance operator's entrance and a transmission cable cut-off device at the outer part of the containment shell, whereby after the construction, the shell is towed, and installed by self-submerging, and it can be refloated for repairs by its own strength. Constitution: Within a containment shell having a ballast tank and a pressure resisting structure, there are provided nuclear power facilities including a nuclear power generating chamber, a maintenance operator's living room and the like. Furthermore, a maintenance operator's entrance and exit device and a transmission cable cut-off device are provided within the shell, whereby when it is towed to a predetermined a area after the construction, it submerges by its own strength and when any repair inspection is necessary, it can float up by its own strength, and can be towed to a repair dock or the like. (Yoshihara, H.)

  14. Nuclear and thermal power plants and the environment

    International Nuclear Information System (INIS)

    Mejstrik, V.

    1978-01-01

    The growth is briefly outlined of world daily power consumption and the possibilities are discussed of meeting this demand. Coal and nuclear power are of primary importance as energy resources for the present and the near future. Production costs per 1 kWh of electric power in nuclear power plants are already lower in fossil fuel power plants and both types of power plants have an environmental impact. Activities are presented of radioisotopes resulting from nuclear reactor operation and their release and environmental impact are discussed. An analysis is made of emissions from combustion processes and of wastes from fossil-fuel power plant operation. The environmental impacts of nuclear and fossil fuel power plants are compared. (Z.M.)

  15. Nuclear and thermal power plants and the environment

    Energy Technology Data Exchange (ETDEWEB)

    Mejstrik, V [Ceskoslovenska Akademie Ved, Pruhonice. Ustav Krajinne Ekologie

    1978-01-01

    The growth is briefly outlined of world daily power consumption and the possibilities are discussed of meeting this demand. Coal and nuclear power are of primary importance as energy resources for the present and the near future. Production costs per 1 kWh of electric power in nuclear power plants are already lower than in fossil fuel power plants and both types of power plants have an environmental impact. Activities are presented of radioisotopes resulting from nuclear reactor operation and their release and environmental impact are discussed. An analysis is made of emissions from combustion processes and of wastes from fossil-fuel power plant operation. The environmental impacts of nuclear and fossil fuel power plants are compared.

  16. Environmental impact of nuclear power stations

    International Nuclear Information System (INIS)

    Kellermann, O.; Balfanz, H.P.

    1975-01-01

    Following a comparative consideration of the present and future environmental impact by coal, oil, and nuclear power plants, the special risks connected with the use of the latter are dealt with. A distinction is made in considering the risk between public exposure, in the environment of a plant due to operational leakage and radiation exposure in the plant under normal operation and in the case of an accident. The accident risk consideration is the basis of the Rasmussen study where the different containment construction of german plants as well as the higher population density for sites in the FRG are considered. Evaluation parameters are given to quantify the risks and using this, the risks of various cases of impact of nuclear power plants are compared. The comparison shows that the risks of nuclear power plant operation according to the value in normal operation are comparable to those in the case of an accident. (ORU/LH) [de

  17. Comparison of health and environmental effects of nuclear power plants and lignite-burning power plants

    International Nuclear Information System (INIS)

    Horacek, P.; Chytil, I.; Razga, J.

    1988-01-01

    The individual factors are discussed which characterize the impact of nuclear power plants and lignite-burning power plants on human health and on the environment. The study proceeds from the IAEA categorization of these impacts. In this light, attention is centred on the impact of the normal operation of power plants and on accidents. The former category is further divided into regional impacts such as the emission of chemical substances, the emission of radioactive substances, heat emissions and the sum of regional factors, and on global impacts such as emissions of carbon dioxide, emissions of long-lived radionuclides and the sum of global impacts. It is stated that research should pay more attention to the dangers of the effects of such a state of affairs when the infrastructure contaminated after a large-scale accident would be put out of operation, and the dangers of such a situation especially in small countries with great population densities. Such accidents represent the biggest danger of the use of nuclear power. The greatest danger of coal-burning power plants is their global impact on the atmosphere caused by the increasing concentration of carbon dioxide from burning fossil fuels. (Z.M.). 4 figs., 13 refs

  18. Chemistry in power plants 2011

    International Nuclear Information System (INIS)

    2011-01-01

    Within the VGB Powertech conference from 25th to 27th October, 2011, in Munich (Federal Republic of Germany), the following lectures and poster contributions were presented: (1) The revised VGB standard for water-steam-cycle Chemistry; (2) Switchover from neutral operation to oxygen treatment at the power station Stuttgart-Muenster of EnBW Kraftwerke AG; (3) Steam contamination with degradation products of organic matters present in the feedwater of the Lanxess-Rubber cogeneration plant; (4) Laboratory scale on-line noble metal deposition experiments simulating BWR plant conditions; (5) Building a new demin installation for the power plant EPZ in Borssele; (6) Replacement of the cooling tower installations in the nuclear power plant Goesgen-Daenien AG; (7) Aging of IEX resins in demin plants - Cost optimisation by adaptation of regenerants; (8) The largest DOW trademark EDI System at a combined cycled plant in Europe; (9) Upgrading river Main water to boiler feed water - Experiences with ultrafiltration; (10) Experiences with treatment of the water-steam-cycle in the RDF power plant Nehlsen Stavenhagen with film-forming amines; (11) Comparative modelling of the bubbles thermal collapse and cavitations for estimation of bubbles collapse influence; (12) Overcoming the steam quality - issues from an HRSG for the production of process steam; (13) Legionella - new requirements for power plant operation; (14) How the right chemistry in the FGD helps to improve the removal in the waste water treatment plant; (15) High efficiency filtration in dry/semi-dry FGD plants; (16) Expanding the variety of renewable fuels in the biomass power plant Timelkam using the chemical input control; (17) Corrosion, operating experiences and process improvements to increase the availability and operating time of the biomass power plant Timelkam; (18) The influence of temperature on the measurement of the conductivity of highly diluted solutions; (19) A multiparameter instrumentation approach

  19. Analysing the economy-wide impact of the supply chains activated by a new biomass power plant. The case of cardoon in Sardinia

    Directory of Open Access Journals (Sweden)

    Andrea Bonfiglio

    2016-05-01

    Full Text Available This study investigates the impact on the economy of Sardinia (Italy generated by a new biomass power plant fed by locally cultivated cardoon. The cardoon also serves the production of biopolymers. The impact is assessed at an economy-wide level using two multiregional closed Input-Output models, which allow us to take into account the entire supply chain activated and the supra-local effects generated by trade across local industries. The effects are computed under alternative scenarios simulating different levels of substitution of existing agricultural activities with the new activity (cardoon. Results show positive and locally significant impacts in terms of value added and employment. However, these impacts are substantially influenced by the degree of substitution. Results also suggest that there are specific territorial areas that are more sensitive to negative effects induced by substitution.

  20. Financing Solar Thermal Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Kistner, Rainer [National Renewable Energy Lab. (NREL), Golden, CO (United States); Price, Henry W. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    1999-04-14

    The commercialization of concentrating solar power technology took a major step forward in the mid 1980s and early 1990s with the development of the SEGS plants in California. Over the years they have proven that parabolic trough power technologies are the most cost-effective approach for commercial scale solar power generation in the sunbelt countries of the world. However, the question must be asked why no additional solar power plants have been build following the bankruptcy of the developer of the SEGS projects, LUZ International Limited. Although many believe the SEGS projects were a success as a result of parabolic trough technology they employ, in truth, the SEGS projects were developed simply because they represented an attractive opportunity for investors. Simply stated, no additional projects have been developed because no one has been able to put together a similarly attractive financial package to potential investors. More than $1.2 billion in private capital was raised in debt and equity financing for the nine SEGS plants. Investors and bankers who make these investments are the real clients for solar power technologies. They are not interested in annual solar to electric efficiencies, but in risk, return on investments, and coverage ratios. This paper will take a look at solar power projects from the financier’s perspective. The challenge in moving forward is to attract private investors, commercial lenders, and international development agencies and to find innovative solutions to the difficult issues that investment in the global power market poses for solar power technologies.

  1. Financing Solar Thermal Power Plants

    International Nuclear Information System (INIS)

    Price, Henry W.; Kistner, Rainer

    1999-01-01

    The commercialization of concentrating solar power technology took a major step forward in the mid 1980s and early 1990s with the development of the SEGS plants in California. Over the years they have proven that parabolic trough power technologies are the most cost-effective approach for commercial scale solar power generation in the sunbelt countries of the world. However, the question must be asked why no additional solar power plants have been build following the bankruptcy of the developer of the SEGS projects, LUZ International Limited. Although many believe the SEGS projects were a success as a result of parabolic trough technology they employ, in truth, the SEGS projects were developed simply because they represented an attractive opportunity for investors. Simply stated, no additional projects have been developed because no one has been able to put together a similarly attractive financial package to potential investors. More than $1.2 billion in private capital was raised in debt and equity financing for the nine SEGS plants. Investors and bankers who make these investments are the real clients for solar power technologies. They are not interested in annual solar to electric efficiencies, but in risk, return on investments, and coverage ratios. This paper will take a look at solar power projects from the financier's perspective. The challenge in moving forward is to attract private investors, commercial lenders, and international development agencies and to find innovative solutions to the difficult issues that investment in the global power market poses for solar power technologies

  2. Financing solar thermal power plants

    International Nuclear Information System (INIS)

    Kistner, R.; Price, H.

    1999-01-01

    The commercialization of concentrating solar power technology took a major step forward in the mid 1980s and early 1990s with the development of the SEGS plants in California. Over the years they have proven that parabolic trough power technologies are the most cost-effective approach for commercial scale solar power generation in the sunbelt countries of the world. However, the question must be asked why no additional solar power plants have been built following the bankruptcy of the developer of the SEGS projects, LUZ International Limited. Although many believe the SEGS projects were a success as a result of parabolic trough technology they employ, in truth, the SEGS projects were developed simply because they represented an attractive opportunity for investors. Simply states, no additional projects have been developed because no one has been able to put together a similarly attractive financial package to potential investors. More than $1.2 billion in private capital was raised in debt and equity financing for the nine SEGS plants. Investors and bankers who make these investments are the real clients for solar power technologies. They are not interested in annual solar to electric efficiencies, but in risk, return on investments, and coverage ratios. This paper will take a look at solar power projects form the financier's perspective. The challenge in moving forward is to attract private investors, commercial lenders, and international development agencies and to find innovative solutions to the difficult issues that investment in the global power market poses for solar power technologies

  3. Thermal Power Plant Performance Analysis

    CERN Document Server

    2012-01-01

    The analysis of the reliability and availability of power plants is frequently based on simple indexes that do not take into account the criticality of some failures used for availability analysis. This criticality should be evaluated based on concepts of reliability which consider the effect of a component failure on the performance of the entire plant. System reliability analysis tools provide a root-cause analysis leading to the improvement of the plant maintenance plan.   Taking in view that the power plant performance can be evaluated not only based on  thermodynamic related indexes, such as heat-rate, Thermal Power Plant Performance Analysis focuses on the presentation of reliability-based tools used to define performance of complex systems and introduces the basic concepts of reliability, maintainability and risk analysis aiming at their application as tools for power plant performance improvement, including: ·         selection of critical equipment and components, ·         defini...

  4. Nuclear power plant diagnostics

    International Nuclear Information System (INIS)

    Hollo, E.; Siklossy, P.

    1982-01-01

    The cooling circuit vibration diagnostic system of the Block 1 of the Paks nuclear power station is described. The automatic online vibration monitoring system consisting presently of 42 acceleration sensors and 9 pressure fluctuation sensors, which could be extended, performs both global and local inspection of the primary cooling circuit and its components. The offline data processing system evaluates the data for failure mode analysis. The software under development will be appropriate for partial preliminary identification of failure reasons during their initial phases. The installation experiences and the preliminary results during the hot operational testing of Block 1 are presented. (Sz.J.)

  5. Operation and maintenance of nuclear power plant

    International Nuclear Information System (INIS)

    1990-04-01

    The proceedings contain 34 papers, almost all discussing specific problems or the Dukovany nuclear power plant. The major part is devoted to the matters of maintenance, regular and unplanned repairs, decontamination of the steam generator for inspection and repair purposes, various methods of in-service diagnostics. Some papers discuss reactor start-up, safety assurance, unit control and economic aspects. Environmental impacts of the power plant are also tackled. Some special contributions concern corrosion, chemical analysis of the coolant and the diagnostics of electrical equipment. The possibility is discussed of switching WWER reactors to improved fuel cycles with increased fuel burnup. (M.D.). 37 figs., 23 tabs., 47 refs

  6. Nuclear power plants

    International Nuclear Information System (INIS)

    Usui, Eizo.

    1981-01-01

    Purpose: To prevent boiling of saturated water in the drain tank of a humidity separator by charging cooling water in the drain tank upon power decrease of a turbine. Constitution: Saturated water is separated from high pressure turbine exhausts in a humidity separator and stored in a drain tank. The saturated water in the drain tank is controlled to a constant level and the excess water is sent to a condensator and a feedwater heater. A cooling water feed pipe is branched as a cooling water feed pipe from the exhaust side of a reactor feedwater pump and connected by way of a closing valve to a spray nozzle provided in the drain tank. While the closing valve is usually closed to keep the water level constant in the drain tank, the closing valve is opened upon sudden decrease in the turbine power to charge the condensates by way of the cooling water feed pipe to the drain tank. Thus, the saturated water is mixed with the dondensates and the temperature is lowered to prevent boiling of the saturated water. (Kawakami, Y.)

  7. Economic impact associated with the decommissioning process of Vandellos I Nuclear Power Plant; Informe final. Impacto economico del desmantelamiento de la central nuclear Vandellos I

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Silva, M.

    2005-07-01

    This economic study examines the economic impact associated with the decommissioning process of the Vandellos I Nuclear Power Plant, measured in terms of the global income that generated the ending of the Nuclear Power Plant activity, on the territory. To this end, we will take into account the total investment that has been necessary to complete the process of decommissioning. The economic impact is calculated using the Input- Output methodology. Briefly, the Input-Output model defines a group of accounting relationships that reflect the links taking place within the production system. The Input-Output model is based on the assumption that given an increase (decrease) in the final demand of one sector, this sector should produce more (less) to satisfy this new demand. At the same time, this will lead to demand more (less) intermediate consumption goods from the remainder sectors of the economy. Then, these sectors should produce more (less) and use more (less) intermediate inputs, and so on. Therefore, an increase (decrease) in the final demand of one sector multiplies the effect throughout the economy, following the interdependency relationships that exist among the productive activities. We will start by collecting an exhaustive economic information. This information covers the whole decommissioning process and the whole economic and productive activity of the province of Tarragona. Next, this information is used with the objective of building an Input-Output table of the province that will serve as a base to establish the global economic impact of Vandellos I. The incomes and employment generation has been evaluated in the province of Tarragona that, following the main assumptions, correspond to the global effects of the decommissioning. In addition, we have evaluated the income and employment generation within the region where the nuclear power plant is located. The total income impacts show a high multiplier effect due to the investment carried out during the

  8. Hydroelectric power and hydroelectric power plants. V. 1

    International Nuclear Information System (INIS)

    1991-06-01

    Following the oil crises of 1973 and 1979, there was renewed and justifiable interest in small hydroelectric plants. The maximum power of these plants rarely exceeds 10 MW, and their development will surely increase in the coming decades. Hydraulic power is a national renewable resource, unaffected by geopolitical problems, and above all, non polluting. Many countries with their own hydraulic resources in both the industrialized and the developing world have expressed needs for the development of small hydroelectric plants. Hidroenergia 91 Conference is the opportunity to take stock of knowledge gained in the vast field of small hydroelectric plants. The meeting is divided into four subjects: 1 methods for decision aid; 2 environmental impact and accompanying answers; 3 national development policy; 4 world market and international cooperation. This meeting contains 75 papers, 8 papers are in the INIS scope and 72 papers are in the ENERGY DATA BASE scope

  9. The impact of water use fees on dispatching and water requirements for water-cooled power plants in Texas.

    Science.gov (United States)

    Sanders, Kelly T; Blackhurst, Michael F; King, Carey W; Webber, Michael E

    2014-06-17

    We utilize a unit commitment and dispatch model to estimate how water use fees on power generators would affect dispatching and water requirements by the power sector in the Electric Reliability Council of Texas' (ERCOT) electric grid. Fees ranging from 10 to 1000 USD per acre-foot were separately applied to water withdrawals and consumption. Fees were chosen to be comparable in cost to a range of water supply projects proposed in the Texas Water Development Board's State Water Plan to meet demand through 2050. We found that these fees can reduce water withdrawals and consumption for cooling thermoelectric power plants in ERCOT by as much as 75% and 23%, respectively. To achieve these water savings, wholesale electricity generation costs might increase as much as 120% based on 2011 fuel costs and generation characteristics. We estimate that water saved through these fees is not as cost-effective as conventional long-term water supply projects. However, the electric grid offers short-term flexibility that conventional water supply projects do not. Furthermore, this manuscript discusses conditions under which the grid could be effective at "supplying" water, particularly during emergency drought conditions, by changing its operational conditions.

  10. The impact of the type of operation on the parameters of a shunting diesel locomotive with hybrid power plant

    Directory of Open Access Journals (Sweden)

    Falendysh Anatoliy

    2017-01-01

    Full Text Available In designing a traction vehicle it is necessary to take into account the type of field operation it is meant for. It was found out that during shunting operation a ChME3 diesel locomotive is in idling mode for almost half of its general running time. That is why, the introduction of a less powerful engine along with an energy storage device for shunting operations at a shunting diesel locomotive is appropriate. The calculations were made using a modernized shunting diesel locomotive ChME3 with hybrid transmission of power as an example. The dependences of the general running time of a diesel locomotive on the position of the engine driver controller under performing shunting, transportation and hump operation were given in percentages. For every operation mode there was calculated the optimum power of a diesel-generator plant and the optimum energy capacity of an energy storage system taking into account the above-mentioned dependences. It was found out that due to the introduction of a hybrid drive for the section discussed above and the corresponding mass of a train the aggregate fuel consumption will be reduced by 25% and the efficiency of travel will increase by one third.

  11. Ocean power plants

    Energy Technology Data Exchange (ETDEWEB)

    Dembicki, E.

    1982-01-01

    In the fall of 1980 on the shores of the Hawaiian Islands, a floating laboratory of the United States was successfully introduced for testing a heat exchanger and pipes for collecting cold water of the OTES with power of 1 MW. The first American OTES N=10-40 MW should start operation in 1985. By the year 2000, ..sigma..N of the U.S. OTES should reach 10 GW. The Japanese OTES N=10-25 MW should start up in 1989. The experimental OTES N=100 KW has been in operation since October 1981 on the Nauru Island. An OTES of 2 MW is under construction. The concern Empain-Schneider is involved in planning the OTES of closed cycle in France, and the concern CGE is planning the OTES of open cycle.

  12. Maintenance of nuclear power plants

    International Nuclear Information System (INIS)

    Lashgari, Farbod.

    1995-01-01

    This paper is about maintenance of nuclear power plants. In part one, the outage management of nuclear power plants has described. Meaning of the outage and objectives of outage management is given in introduction. The necessity of a long-term outage strategy is shown in chapter one. The main parts of an outage are as follows: Planning; Preparation; Execution, Each of them and also post-outage review have been explained in the followed chapters. Part two deals with technical details of main primary components of nuclear power plant type WWER. After an introduction about WWER reactors, in each chapter first the general and detailed description of main primary components has given and then their maintenance schedules and procedures. Chapter about reactor and steam generator is related to both types of WWER-440 and WWER-1000, but chapter about reactor coolant pump has specified to WWER-1000 to be more in details.(author)

  13. Toxic releases from power plants

    International Nuclear Information System (INIS)

    Rubin, E.S.

    1999-01-01

    Beginning in 1998, electric power plants burning coal or oil must estimate and report their annual releases of toxic chemicals listed in the Toxics Release Inventory (TRI) published by the US Environmental Protection Agency (EPA). This paper identifies the toxic chemicals of greatest significance for the electric utility sector and develops quantitative estimates of the toxic releases reportable to the TRI for a representative coal-fired power plant. Key factors affecting the magnitude and types of toxic releases for individual power plants also are discussed. A national projection suggests that the magnitude of electric utility industry releases will surpass those of the manufacturing industries which current report to the TRI. Risk communication activities at the community level will be essential to interpret and provide context for the new TRI results

  14. Thermal power plants and environment

    International Nuclear Information System (INIS)

    1997-01-01

    Recent versions of the air quality models which are reviewed and approved from the Environmental Protection Agency (EPA) are analysed in favour of their application in simple and complex terrain, different meteorological conditions and modifications in the sources of pollutant emissions. Improvement of the standard methods for analysis of the risks affecting the environment from different energy sources has been carried out. The application of the newly introduced model enabled (lead to performing) risk analysis of the coal power plants compared to other types of energy sources. Detailed investigation of the risk assessment and perception from coal power plants, has been performed and applied to the Macedonian coal power plants. Introducing the concept of 'psychological pollution', a modification of the standard models and programs for risk assessment from various energy sources has been suggested (proposed). The model has been applied to REK Bitola, where statistically relevant differences in relation to the control groups have been obtained. (Original)

  15. THE LOCAL IMPACTS OF MERCURY EMISSIONS FROM COAL FIRED POWER PLANTS ON HUMAN HEALTH RISK. PROGRESS REPORT FOR THE PERIOD OF MARCH 2003 - MARCH 2003.

    Energy Technology Data Exchange (ETDEWEB)

    SULLIVAN,T.M.LIPFERT,F.D.MORRIS,S.M.

    2003-05-01

    This report presents a follow-up to previous assessments of the health risks of mercury that BNL performed for the Department of Energy. Methylmercury is an organic form of mercury that has been implicated as the form of mercury that impacts human health. A comprehensive risk assessment report was prepared (Lipfert et al., 1994) that led to several journal articles and conference presentations (Lipfert et al. 1994, 1995, 1996). In 2001, a risk assessment of mercury exposure from fish consumption was performed for 3 regions of the U.S (Northeast, Southeast, and Midwest) identified by the EPA as regions of higher impact from coal emissions (Sullivan, 2001). The risk assessment addressed the effects of in utero exposure to children through consumption of fish by their mothers. Two population groups (general population and subsistence fishers) were considered. Three mercury levels were considered in the analysis, current conditions based on measured data, and hypothetical reductions in Hg levels due to a 50% and 90% reduction in mercury emissions from coal fired power plants. The findings of the analysis suggested that a 90% reduction in coal-fired emissions would lead to a small reduction in risk to the general population (population risk reduction on the order of 10{sup -5}) and that the population risk is born by less than 1% of the population (i.e. high end fish consumers). The study conducted in 2001 focused on the health impacts arising from regional deposition patterns as determined by measured data and modeling. Health impacts were assessed on a regional scale accounting for potential percent reductions in mercury emissions from coal. However, quantitative assessment of local deposition near actual power plants has not been attempted. Generic assessments have been performed, but these are not representative of any single power plant. In this study, general background information on the mercury cycle, mercury emissions from coal plants, and risk assessment are

  16. Robotics for nuclear power plants

    International Nuclear Information System (INIS)

    Nakayama, Ryoichi; Kimura, Motohiko; Abe, Akira

    1993-01-01

    A continuing need exists for automatic or remote-controlled machines or robots which can perform inspection and maintenance tasks in nuclear power plants. Toshiba has developed several types of monofunctional and multi- functional robots for such purposes over the past 20 years, some of which have already been used in actual plants. This paper describes new multifunctional robots for inspection and maintenance. An inspection robot has been applied in an actual plant for two years for performance testing. Maintenance robots for grinding tasks have also been developed, which can be easily teleoperated by the operator using automatic control. These new robots are expected to be applied to actual inspection and maintenance work in nuclear power plants. (author)

  17. Corrosion-related failures in power plant condensers. Final report

    International Nuclear Information System (INIS)

    Beavers, J.A.; Agrawal, A.K.; Berry, W.E.

    1980-08-01

    A survey of the literature has been conducted for the Electric Power Research Institute on corrosion failures in surface condensers. The survey was directed toward condenser failures in pressurized water reactor (PWR) power plants but includes pertinent literature related to fossil and to other nuclear power plants. It includes literature on reported service failures and on experimental studies that impact on these failures

  18. Nuclear power plant

    International Nuclear Information System (INIS)

    Inami, Ichiro; Kobayashi, Minoru.

    1995-01-01

    In a condensate cleanup system and a reactor water cleanup system of a BWR-type reactor, in which primary coolants flow, there is disposed a filtering and desalting device using hollow thread membrane filter and ion exchange resin for a condensate cleanup system, and using a high temperature filter made of a metal, a metal oxide or ceramics as a filtering material and a precoat filter made of a powdery ion exchange resin as a filtering material for a reactor water cleanup system. This can completely remove cruds generated in the condensate system. Since the reactor water cleanup system comprises the powdery resin precoat-type filtering and desalting device and the high temperature filter using ceramics, ionic impurities such as radioactive materials can be removed. Accordingly, cruds are not carried into the inside of the reactor, and since the radioactive concentration in the reactor water is reduced, radiation exposure upon periodical inspection can be minimized almost to zero, to attain a clean plant. (T.M.)

  19. Interactions of Corbicula sp. with power plants

    International Nuclear Information System (INIS)

    Mattice, J.S.

    1977-01-01

    There are three perspectives with which to view the interaction of Corbicula and power plants: as a fouling agent; as an important part of the natural ecosystem; and as a potential species for use in waste heat aquaculture. The first two of these interactions are essentially negative in character, since they involve avoidance of impacts either of Corbicula on power plant operation or of power plant operation on Corbicula. Condenser fouling by these claims has been controlled by mechanical means or by continuous chlorination. Our data support the potential for using heated water to control fouling and a model for determining required thermal dosing is presented. Preliminary data also indicate potential for control by combining simultaneous short-term exposure to hot water and chlorine. The third of the interactions is essentially positive in character. The use of thermal effluents in Corbicula aquaculture systems is proposed

  20. Cooling water requirements and nuclear power plants

    International Nuclear Information System (INIS)

    Rao, T.S.

    2010-01-01

    Indian nuclear power programme is poised to scuttle the energy crisis of our time by proposing joint ventures for large power plants. Large fossil/nuclear power plants (NPPs) rely upon water for cooling and are therefore located near coastal areas. The amount of water a power station uses and consumes depends on the cooling technology used. Depending on the cooling technology utilized, per megawatt existing NPPs use and consume more water (by a factor of 1.25) than power stations using other fuel sources. In this context the distinction between 'use' and 'consume' of water is important. All power stations do consume some of the water they use; this is generally lost as evaporation. Cooling systems are basically of two types; Closed cycle and Once-through, of the two systems, the closed cycle uses about 2-3% of the water volumes used by the once-through system. Generally, water used for power plant cooling is chemically altered for purposes of extending the useful life of equipment and to ensure efficient operation. The used chemicals effluent will be added to the cooling water discharge. Thus water quality impacts on power plants vary significantly, from one electricity generating technology to another. In light of massive expansion of nuclear power programme there is a need to develop new ecofriendly cooling water technologies. Seawater cooling towers (SCT) could be a viable option for power plants. SCTs can be utilized with the proper selection of materials, coatings and can achieve long service life. Among the concerns raised about the development of a nuclear power industry, the amount of water consumed by nuclear power plants compared with other power stations is of relevance in light of the warming surface seawater temperatures. A 1000 MW power plant uses per day ∼800 ML/MW in once through cooling system; while SCT use 27 ML/MW. With the advent of new marine materials and concrete compositions SCT can be constructed for efficient operation. However, the

  1. VGB congress 'Power Plants 2009'

    International Nuclear Information System (INIS)

    Anon.

    2009-01-01

    The VGB Congress 'Power Plants 2009' took place in Lyon/France from 23rd to 25th September 2009 and was themed 'Addressing Climate Change - Winning Public Acceptance through Advanced Technologies'. Nearly 1,300 participants attended the plenary and technical lectures and had the opportunity to discus the current topics of electricity and heat generation. The study carried out by VGB according to which EU-27 requires about 475.000 MW of new power plant capacity was also presented. Specific papers were addressing further topics. The Congress was rounded off by a side-programme and technical visits. (orig.)

  2. Kuroshio power plant development plan

    International Nuclear Information System (INIS)

    Chen, Falin

    2010-01-01

    As a country lacking energy reserves, Taiwan imports 99.2% of its energy, with only a small portion of indigenous energy, such as hydro, wind, and solar. In 2008, each Taiwanese spent 85,000 NTD dollars (1 USD ∝ 32 NTD) to purchase oil, coal, gas, and nuclear fuel from foreign countries, accounting for a total payment of 1.8 trillion NTD, more than the annual budget of the Taiwan government of 1.7 trillion NTD. In the same year, Taiwan emitted about 1% of the world's greenhouse gas (GHG), or 12 tons per person-year, ranking 18th globally. These situations in terms of energy security and carbon emission are very severe. To resolve these severe situations, harnessing the power of the Kuroshio in eastern Taiwan offers a great opportunity. The Kuroshio is a branch of the North Pacific Ocean current. Due to the westward-enhanced effect, this ocean current is strong and stable as it passes through eastern Taiwan. The flow rate is about 30 sverdrup (Sv) or 1000 times that of the Yangtze River, the average speed is 1 m/s, the flow direction is fixed to the north, and the flow path is close to the east coast of Taiwan. By precisely locating high-quality sites and implementing sequential works with careful planning, one can possibly generate exploitable power more than 30 GW. With 30 GW of clean energy, Taiwan could effectively enhance energy security, reduce GHG emission, and lower energy-purchasing cost. This paper proposes a feasibility study to explore the power of the Kuroshio. The content consists of four parts: (1) assessment of Kuroshio power reserves, (2) development of turbine generators, (3) development of turbine-anchor system, and (4) deep-sea marine engineering of turbine clusters. By integrating these technologies above, we propose a project to construct a 30 MW pilot plant. In this project, we also discuss the financial analysis and propose new regulations, environmental impact analysis, risk assessment, and other relevant issues. (author)

  3. A review of public desert land lease policies for concentrated solar power plants and the impact on their economic performance

    Science.gov (United States)

    Smyrnakis, Christos; Phocas-Cosmetatos, Alex; Kynigalakis, Kostantinos

    2016-05-01

    Large scale Concentrated Solar Power (CSP) plants need large plots of land with very high solar resource and thus are often deployed in desert areas which are usually owned by the state or a municipal authority. This study discusses the implication and practices of land lease policies with regards to CSP development. The strategy followed on a land lease is examined by definition on a case-specific basis and this text is by no means exhaustive with regards to its content. The study also discusses the pricing of land in various cases, presents the governing types of land lease and their effect on the economic performance of hypothetical CSP projects under various cases.

  4. Improved HYLIFE-II heat transport system and steam power plant: Impact on performance and cost of electricity

    International Nuclear Information System (INIS)

    Hoffman, M.A.; Lee, Ying T.

    1992-12-01

    The HYLIFE-II conceptual design has evolved and improved continually over the past four years to its present form. This paper describes the latest FY92 versions, Reference Case H1 (nominally 1 GWe net output) and the Enhanced Case HE (nominally 2 GWe net output), which take advantage of improvements in the tritium management system to eliminate the intermediate loop and the intermediate heat exchangers (IHX's). The improvements in the heat transport system and the steam power plant are described and the resulting cost reductions are evaluated. The new estimated cost of electricity (in 1990 dollars) is 6.6 cents/kWh for Reference Case H1 and 4.7 cents/kWh for the Enhanced Case

  5. Loviisa nuclear power plant analyzer

    International Nuclear Information System (INIS)

    Porkholm, K.; Nurmilaukas, P.; Tiihonen, O.; Haenninen, M.; Puska, E.

    1992-12-01

    The APROS Simulation Environment has been developed since 1986 by Imatran Voima Oy (IVO) and the Technical Research Centre of Finland (VTT). It provides tools, solution algorithms and process components for use in different simulation systems for design, analysis and training purposes. One of its main nuclear applications is the Loviisa Nuclear Power Plant Analyzer (LPA). The Loviisa Plant Analyzer includes all the important plant components both in the primary and in the secondary circuits. In addition, all the main control systems, the protection system and the high voltage electrical systems are included. (orig.)

  6. Operation of nuclear power plants

    International Nuclear Information System (INIS)

    Severa, P.

    1988-04-01

    The textbook for training nuclear power plant personnel is centred on the most important aspects of operating modes of WWER-440 reactors. Attention is devoted to the steady state operation of the unit, shutdown, overhaul with refuelling, physical and power start-up. Also given are the regulations of shift operation and the duties of individual categories of personnel during the shift and during the change of shifts. (Z.M.). 3 figs., 1 tab

  7. Nuclear power plant transients: where are we

    International Nuclear Information System (INIS)

    Majumdar, D.

    1984-05-01

    This document is in part a postconference review and summary of the American Nuclear Society sponsored Anticipated and Abnormal Plant Transients in Light Water Reactors Conference held in Jackson, Wyoming, September 26-29, 1983, and in part a reflection upon the issues of plant transients and their impact on the viability of nuclear power. This document discusses state-of-the-art knowledge, deficiencies, and future directions in the plant transients area as seen through this conference. It describes briefly what was reported in this conference, emphasizes areas where it is felt there is confidence in the nuclear industry, and also discusses where the experts did not have a consensus. Areas covered in the document include major issues in operational transients, transient management, transient events experience base, the status of the analytical tools and their capabilities, probabilistic risk assessment applications in operational transients, and human factors impact on plant transients management

  8. Building of nuclear power plant

    International Nuclear Information System (INIS)

    Saito, Takashi.

    1997-01-01

    A first nuclear plant and a second nuclear power plant are disposed in adjacent with each other in a building for a nuclear reactor. A reactor container is disposed in each of the plants, and each reactor container is surrounded by a second containing facility. A repairing chamber capable of communicating with the secondary containing facilities for both of the secondary containing facilities is disposed being in contact with the second containing facility of each plant for repairing control rod driving mechanisms or reactor incorporated-type recycling pumps. Namely, the repairing chamber is in adjacent with the reactor containers of both plants, and situated between both of the plants as a repairing chamber to be used in common for both plants. Air tight inlet/exit doors are formed to the inlets/exits of both plants of the repairing chamber. Space for the repairing chamber can be reduced to about one half compared with a case where the repairing chamber is formed independently on each plant. (I.N.)

  9. Progressive decommissioning of French nuclear power plants: economic and geopolitical impacts; Declassement progressif du parc nucleaire francais: impacts economiques et geopolitiques

    Energy Technology Data Exchange (ETDEWEB)

    Noel, P

    1998-09-01

    The author analyzes the french energy safety in the next twenty years. The first part is devoted to the electric production park structure in 2020, with a presentation of the electric power economy, the carbon cost introduction and the economic choices in the deregulation system. The second part discusses the economical and geopolitical impacts of a gas-nuclear substitution. (A.L.B.)

  10. Off-shore nuclear power plant

    International Nuclear Information System (INIS)

    Nakanishi, T.

    1980-01-01

    In order to avoid losses of energy and seawater pollution an off-shore nuclear power plant is coupled with a power plant which utilizes the temperature difference between seawater and hot reactor cooling water. According to the invention the power plant has a working media loop which is separated from the nuclear power plant. The apparative equipment and the operational characteristics of the power plant are the subject of the patent. (UWI) [de

  11. The role of the visitors' centre during the decommissioning of the Greifswald nuclear power plant and the impact on the public

    International Nuclear Information System (INIS)

    Brauer, D.

    1993-01-01

    In the Energiewerke Nord (EWN) GmbH, the former Nuclear Power Plant (NPP) Greifswald have been the units 1 to 5 shut down finally. The units 6 to 8 are in different stages of construction, but it will not be continued. The current situation, tasks and perspectives at the Greifswald NPP site are briefly described. The main tasks are the post-operation, the decommissioning and the establishment of an industrial area. Considering the situation at the Greifswald site the particularities and necessities and the influence of the Visitors' centre on the neighbouring villages, communities, population and the impact on the public are discussed. (author)

  12. Considerations about the impact of the Convention on Nuclear Safety on the regulatory action of the CNEN in Brazilian nuclear power plants

    International Nuclear Information System (INIS)

    Camargo, Claudio; Pontedeiro, Auro

    1995-01-01

    Preliminary discussion is conducted about the impact of the terms of the Convention on Nuclear safety, adopted by Diplomatic Conference in September 1994 in the International Atomic Energy Agency, on the regulatory action of Brazilian Nuclear Regulatory Body - CNEN. Following the Convention articles structure, the paper emphasizes technical aspects of the nuclear safety standards adopted in the licensing process of Brazilian Nuclear Power Plants. The recent experience in the issuance of Angra-1 NPP Permanent Operation Authorization is used to demonstrate that current safety standards in Brazil are in compliance with the international compromises and in agreement with what is expected by the so called Safety Culture. (author). 9 refs

  13. Docommissioning of nuclear power plants

    International Nuclear Information System (INIS)

    Essmann, J.

    1981-01-01

    The German utilities operating nuclear power plants have long concerned themselves with aspects of decommissioning and for this purpose an engineering company was given a contract to study the entire spectrum of decommissioning. The results of this study have been available in autumn 1980 and it is possible to discuss all the aspects of decommissioning on a new basis. Following these results no change in the design concept of LWR nuclear power plants in operation or under construction is necessary because the techniques, necessary for decommissioning, are fully available today. The technical feasibility of decommissioning for power plants of Biblis A and KRB type has been shown in detail. The calculations of the quantity of waste produced during removal of a nuclear power plant could be confirmed and it could be determined with high procedure. The radiation dose to the decommissioning personnel is in the range of the radiation protection regulations and is in the same range as the radiation dose to the personnel within a yearly inservice inspection. (AF)

  14. Fire protection in power plants

    International Nuclear Information System (INIS)

    Penot, J.

    1986-01-01

    Graphex-CK 23 is a unique sodium fire extinction product. Minimum amounts of powder are required for very fast action. The sodium can be put to use again, when the fire has been extinguished. It can be applied in other industrial branches and with other metals, e.g. sodium/potassium circuits or lithium coolant in power plants. [de

  15. Noise from wind power plants

    International Nuclear Information System (INIS)

    Ljunggren, S.

    2001-12-01

    First, the generation of noise at wind power plants and the character of the sound is described. The propagation of the sound and its dependence on the structure of the ground and on wind and temperature is treated next. Models for calculation of the noise emission are reviewed and examples of applications are given. Different means for reducing the disturbances are described

  16. Underwater nuclear power plant structure

    International Nuclear Information System (INIS)

    Severs, S.; Toll, H.V.

    1982-01-01

    A structure for an underwater nuclear power generating plant comprising a triangular platform formed of tubular leg and truss members upon which are attached one or more large spherical pressure vessels and one or more small cylindrical auxiliary pressure vessels. (author)

  17. World nuclear power plant capacity

    International Nuclear Information System (INIS)

    1991-01-01

    This report provides the background information for statistics and analysis developed by NUKEM in its monthly Market Report on the Nuclear Fuel Cycle. The assessments in this Special Report are based on the continuous review of individual nuclear power plant projects. This Special Report begins with tables summarizing a variety of nuclear power generating capacity statistics for 1990. It continues with a brief review of the year's major events regarding each country's nuclear power program. The standard NUKEM Market Report tables on nuclear plant capacity are given on pages 24 and 25. Owing to space limitations, the first year shown is 1988. Please refer to previous Special Reports for data covering earlier years. Detailed tables for each country list all existing plants as well as those expected by NUKEM to be in commercial operation by the end of 2005. An Appendix containing a list of abbreviations can be found starting on page 56. Only nuclear power plants intended for civilian use are included in this Special Report. Reactor lifetimes are assumed to be 35 years for all light water reactors and 30 years for all other reactor types, unless other data or definite decommissioning dates have been published by the operators. (orig./UA) [de

  18. Nuclear power plant emergency preparedness

    International Nuclear Information System (INIS)

    2005-01-01

    The guide sets forth detailed requirements on how the licensee of a nuclear power plant shall plan, implement and maintain emergency response arrangements. The guide is also applied to nuclear material and nuclear waste transport in situations referred to in guide YVL 6.5. Requirements on physical protection are presented in a separate guide of Finnish Radiation and Nuclear Safety Authority (STUK)

  19. Westinghouse ICF power plant study

    International Nuclear Information System (INIS)

    Sucov, E.W.

    1980-10-01

    In this study, two different electric power plants for the production of about 1000 MWe which were based on a CO 2 laser driver and on a heavy ion driver have been developed and analyzed. The purposes of this study were: (1) to examine in a self consistent way the technological and institutional problems that need to be confronted and solved in order to produce commercially competitive electricity in the 2020 time frame from an inertial fusion reactor, and (2) to compare, on a common basis, the consequences of using two different drivers to initiate the DT fuel pellet explosions. Analytic descriptions of size/performance/cost relationships for each of the subsystems comprising the power plant have been combined into an overall computer code which models the entire plant. This overall model has been used to conduct trade studies which examine the consequences of varying critical design values around the reference point

  20. Impact of nuclear power plant construction relative to decommissioning fossil fuel plants in order to reduce CO{sub 2} emissions using a modified Nordhaus Vensim DICE model

    Energy Technology Data Exchange (ETDEWEB)

    Tokuhiro, A.; Colpetzer, J., E-mail: tokuhio@uidaho.edu, E-mail: colp8921@vandals.uidaho.edu [Univ. of Idaho, Idaho Falls, ID (United States)

    2014-07-01

    The current levels of CO{sub 2} emissions and high levels accumulating in the atmosphere have climate scientists concerned. The Dynamic Integrated Climate Economy Model or 'DICE' is a model that is used to simulate climate change and evaluate factors to address global warming. The model was developed by Nordhaus and collaborators. The DICE model uses current economic and environmental data to predict potential climate change as a result of an increase in CO{sub 2} in the atmosphere. The authors recreated the Fiddaman DICE model using Vensim and modified it to evaluate the use of nuclear power plants (NPPs) as a means to counter climate change, as characterize by temperature increases in the atmosphere and oceans and the associated cost of damages. The amount of GHG emissions from a NPP are about 6% per MWe, as that from a fossil-fueled power plant (FFPP). Based on this fact, a model was developed to simulate construction of NPPs with subsequent decommissioning of FFPPs with an equivalent power output. The study looked at extended periods into the future; that is, up to year 2300. Based on the results produced from this study it can be concluded that using NPPs in the U.S. to address climate change will provide a small benefit, but ultimately will not be enough to reduce CO{sub 2} emissions nor atmospheric CO{sub 2} to mitigate global warming. The amount of CO{sub 2} in the atmosphere is predicted to be 1055 parts per million even in the best case scenario by year 2300. This far exceeds the often quoted 350 ppm concentration. The results may have policy ramifications as well as significance with respect to the seriousness of continuing increase in CO{sub 2} concentration. The paper will discuss results and implications. (author)

  1. Power conditioning devices in nuclear power plants

    International Nuclear Information System (INIS)

    Shida, Toichi.

    1979-01-01

    Purpose: To automatically prevent the liquid level from lowering in a reactor even if a feedwater adjusting valve is locked in a bwr type nuclear power plant. Constitution: Where a feedwater adjusting valve should be locked, and if the mismatching degree between the main steam flow rate and the feedwater flow rate exceeds a predetermined value and the mismatched state continues for a certain period, the value set to a main control for setting the recycling flow rate is changed corresponding to the mismatching degree to compensate the same thereby preventing the liquid level from lowering in the reactor. (Ikeda, J.)

  2. Dynamic Impact of Fluoride Dust on Industrial Workers in Thermal Power Plant and its Feasibility Study on Troposphere

    Science.gov (United States)

    Katiyar, Swati; Kumar, Pawan

    2016-07-01

    Fluorine is a common element that does not occur in the elemental state in nature because of its high reactivity. It accounts for about 0.3 g kg-1 of the Earth's crust and exists in the form of fluorides in a number of minerals, of which fluorspar, cryolite and fluorapatite are the most common. This paper focuses on the analysis of flouride on the industrial workers in various working conditions on troposphere. To check the impact of flouride on workers various samples were taken from different conditions of aluminum plant industries like pot room workers and non-pot room workers as fluoride has both beneficial and detrimental effects on human health. 50 workers in pot room and 10 workers in non pot room were chosen for taking urine and serum samples. 0.09 to 3.77 mg Kg -1 and 0.39 to 1.15 mg Kg-1 (of ash weight) was recorded in the nails of pot room and non pot room workers respectively. The average flouride content was recorded as 1.10 mg Kg -1 and 0.65 mg Kg -1 in pot room and non pot room workers respectively. The outcome results clearly indicated the ill effect and dangerous for the dental health as well as physical health of the workers. A preventive measure or precaution should be taken by the management or persons to avoid the impact of flouride on the body. The clinical significance lie in the maintaining hygienic condition while preventing the any possible effect of flouride on the workers of the industries, as this will affect the production as well as the human value in term of physical capabilities and social aspects in providing medical facilities. Keywords: Fluoride, Ecosystem, Dynamic impact, Air pollutant, detrimental effects.

  3. The impact of nuclear power stations and of a fuel reprocessing plant on the Rhone river and its prodelta

    International Nuclear Information System (INIS)

    Foulquier, L.; Garnier-Laplace, J.; Lambrechts, A.; Charmasson, S.; Pally, M.

    1992-01-01

    The Rhone, with its 6 nuclear sites (17 reactors of various types and a fuel reprocessing unit), presents a relevant example for comparing the impact of these various installations on the aquatic ecosystem. Artificial radioactivity (γ emitters, Pu, 3 H, 90 Sr...) and natural radioactivity are monitored in sediments and various living organisms in the river and its prodelta. A summary of the radioecological procedure is given and illustrated with examples selected from results obtained over the last fifteen years (data resulting from about 7500 samples taken up- and downstream of the installations and in the prodelta). The evolution of results obtained during this period by γ spectrometry on fish up- and downstream of the nuclear power station at Bugey and the Marcoule fuel reprocessing unit is presented. The role of aquatic vegetation as indicator of radiocontamination is also illustrated. The evolution in the concentration levels of γ emitting artificial radionuclides in sediments and mussels in the prodelta is commented on in order to show the global radioecological impact of the Rhone in the Mediterranean sea. The analyses presented show that it is possible to quantify the influence of each source term on the total artificial radioactivity of the compartments of the ecosystem. The source terms are atmospheric fallout from early nuclear weapon tests and of the Chernobyl accident, and liquid wastes of various composition from nuclear installations

  4. Knowledge management for the decommissioning of nuclear power plants

    International Nuclear Information System (INIS)

    Kirschnick, F.; Engelhardt, S.

    2004-01-01

    This paper describes background, objectives and select conceptual components of knowledge management for the decommissioning of nuclear power plants. The concept focuses on the transfer of personal practice experience within and between nuclear power plants. The conceptual insights embrace aspects of knowledge content, structure, KM processes, organization, cooperation, culture, persuasion, leadership, technology, infrastructure, business impact and resilience. Key challenges are discussed, and related advice is provided for KM practitioners with similar endeavours in the field of nuclear power plant decommissioning. (author)

  5. Power plant cost estimates put to the test

    International Nuclear Information System (INIS)

    Crowley, J.H.

    1978-01-01

    The growth in standards for nuclear applications and the impact of these codes and standards on the cost of nuclear power plants is described. The preparation of cost estimates and reasons for apparent discrepancies are discussed. Consistent estimates of nuclear power plant costs have been prepared in the USA for over a decade. They show that the difference in capital costs between nuclear and coal fired plants is narrowing and that when total generating costs are calculated nuclear power is substantially cheaper. (UK)

  6. Thermonuclear power plants and the environment

    International Nuclear Information System (INIS)

    Becka, J.

    1978-01-01

    Environmental safety and protection from the effects of the thermonuclear power plants are discussed. Factors are assessed which should be considered in the choice of fuel and breeding material of a thermonuclear reactor, the problems of structural material activation and the overall reactor concepts. Main specifications are given of the US thermonuclear power plant projects with D-T reaction based reactors. The overall amounts of tritium in the reactor cycles are shown. The potential biological risk is evaluated for the different materials considered for the UWMAK-1 project. Discussed are possible pathways of activity release in normal plant operation, non-radioactive aspects, such as waste heat, the magnetic field effect on personnel and population, etc., as well as possible environmental impacts in case of accidents. (B.S.)

  7. Nuclear Power Plant Concrete Structures

    Energy Technology Data Exchange (ETDEWEB)

    Basu, Prabir [International Atomic Energy Agency (IAEA); Labbe, Pierre [Electricity of France (EDF); Naus, Dan [Oak Ridge National Laboratory (ORNL)

    2013-01-01

    A nuclear power plant (NPP) involves complex engineering structures that are significant items of the structures, systems and components (SSC) important to the safe and reliable operation of the NPP. Concrete is the commonly used civil engineering construction material in the nuclear industry because of a number of advantageous properties. The NPP concrete structures underwent a great degree of evolution, since the commissioning of first NPP in early 1960. The increasing concern with time related to safety of the public and environment, and degradation of concrete structures due to ageing related phenomena are the driving forces for such evolution. The concrete technology underwent rapid development with the advent of chemical admixtures of plasticizer/super plasticizer category as well as viscosity modifiers and mineral admixtures like fly ash and silica fume. Application of high performance concrete (HPC) developed with chemical and mineral admixtures has been witnessed in the construction of NPP structures. Along with the beneficial effect, the use of admixtures in concrete has posed a number of challenges as well in design and construction. This along with the prospect of continuing operation beyond design life, especially after 60 years, the impact of extreme natural events ( as in the case of Fukushima NPP accident) and human induced events (e.g. commercial aircraft crash like the event of September 11th 2001) has led to further development in the area of NPP concrete structures. The present paper aims at providing an account of evolution of NPP concrete structures in last two decades by summarizing the development in the areas of concrete technology, design methodology and construction techniques, maintenance and ageing management of concrete structures.

  8. Impact of natural disaster combined with nuclear power plant accidents on local medical services: a case study of Minamisoma Municipal General Hospital after the Great East Japan Earthquake.

    Science.gov (United States)

    Kodama, Yuko; Oikawa, Tomoyoshi; Hayashi, Kaoru; Takano, Michiko; Nagano, Mayumi; Onoda, Katsuko; Yoshida, Toshiharu; Takada, Akemi; Hanai, Tatsuo; Shimada, Shunji; Shimada, Satoko; Nishiuchi, Yasuyuki; Onoda, Syuichi; Monma, Kazuo; Tsubokura, Masaharu; Matsumura, Tomoko; Kami, Masahiro; Kanazawa, Yukio

    2014-12-01

    To elucidate the impacts of nuclear plant accidents on neighboring medical centers, we investigated the operations of our hospital within the first 10 days of the Great East Japan Earthquake followed by the Fukushima Daiichi nuclear power plant accident. Data were extracted from medical records and hospital administrative records covering 11 to 20 March 2011. Factual information on the disaster was obtained from public access media. A total of 622 outpatients and 241 inpatients were treated. Outpatients included 43 injured, 6 with cardiopulmonary arrest, and 573 with chronic diseases. Among the 241 inpatients, 5 died, 137 were discharged, and the other 99 were transferred to other hospitals. No communication methods or medical or food supplies were available for 4 days after the earthquake. Hospital directors allowed employees to leave the hospital on day 4. All 39 temporary workers were evacuated immediately, and 71 of 239 full-time employees remained. These employees handled extra tasks besides patient care and patient transfer to other hospitals. Committed effective doses indicating the magnitude of health risks due to an intake of radioactive cesium into the human body were found to be minimal according to internal radiation exposure screening carried out from July to August 2011. After the disaster, hospitals located within the evacuation zone of a 30-km radius of the nuclear power plant were isolated. Maintenance of the health care system in such an event becomes difficult.

  9. Radiological Impact Study of the Coal-Fired Power Plant of La Robla; Estudio del Impacto Radiologico de la Central Termica de Carbon de La Robla

    Energy Technology Data Exchange (ETDEWEB)

    Robles, B.; Mora, J. C.; Trueba, C.; Rodriguez, J.; Baeza, A.; Corbacho, J. A.; Guillen, J.; Miralles, Y.

    2013-07-01

    Coal, fuel used in thermal power plants for electricity production, contains variable concentrations of naturally occurring radionuclides from natural disintegration series of 238{sup U}, 235{sup U}, 232{sup T}h and also the 40{sup K}, which are enhanced in the wastes and coproducts due to the industrial process. For this reason, natural radionuclides which are part of the non-combustible fraction of coal, except those volatiles which incorporate directly to the flue gases, concentrates and are partitioned between fly ashes and bottom ashes. This enhancement could cause, to the workers of the installation and to members of the public around the plant, an increase in the exposure which should be assessed under the radiation protection point of view. Present report collect the results obtained from a screening assessment of the radiological impact derived from the normal operation of the La Robla coal-fired power plant. The project where this assessment was performed is part of a bigger project which is jointly developed by the Unit of Radiation Protection of the Public and the Environment (UPRPYMA) of CIEMAT and the Environmental Radioactivity Laboratory of the Extremadura University (LARUEX) in agreement with the Spanish Association of the Electrical Industry (ENUSA). (Author)

  10. Radiological Impact Study of the Coal-Fired Power Plant of La Robla; Estudio del Impacto Radiologico de la Central Termica de Carbon de La Robla

    Energy Technology Data Exchange (ETDEWEB)

    Robles, B.; Baeza, A.; Mora, J. C.; Corbacho, J. A.; Trueba, C.; Guillen, J.; Rodriguez, J.; Miralles, Y.

    2014-04-01

    Coal, fuel used in thermal power plants for electricity production, contains variable concentrations of naturally occurring radionuclides from natural disintegration series of {sup 2}38U, {sup 2}35U, {sup 2}32Th and also the 40K, which are enhanced in the wastes and coproducts due to the industrial process. For this reason, natural radionuclides which are part of the noncombustible fraction of coal, except those volatiles which incorporate directly to the flue gases, concentrates and are partitioned between fly ashes and bottom ashes. This enhancement could cause, to the workers of the installation and to members of the public around the plant, an increase in the exposure which should be assessed under the radiation protection point of view. Present report collect the results obtained from a screening assessment of the radiological impact derived from the normal operation of the La Robla coal-fired power plant. The project where this assessment was performed is part of a bigger project which is jointly developed by the Unit of Radiation Protection of the Public and the Environment (UPRPYMA) of CIEMAT and the Environmental Radioactivity Laboratory of the Extremadura University (LARUEX) in agreement with the Spanish Association of the Electrical Industry (ENUSA). (Author)

  11. Radiological Impact Study of the Coal-Fired Power Plant of Velilla; Estudio del Impacto Radiologico de la Central Termica de Carbon de Velilla

    Energy Technology Data Exchange (ETDEWEB)

    Robles, B.; Mora, J. c.; Trueba, C.; Rodriguez, J.; Baeza, A.; Corbacho, J. a.; Guillen, J.; Miralles, Y.

    2013-10-01

    Coal, fuel used in thermal power plants for electricity production, contains variable concentrations of naturally occurring radionuclides from natural disintegration series of 238U, 235U, 232Th and also the 40K, which are enhanced in the wastes and coproducts due to the industrial process. For this reason, natural radionuclides which are part of the non-combustible fraction of coal, except those volatiles which incorporate directly to the flue gases, concentrates and are partitioned between fly ashes and bottom ashes. This enhancement could cause, to the workers of the installation and to members of the public around the plant, an increase in the exposure which should be assessed under the radiation protection point of view. Present report collect the results obtained from a screening assessment of the radiological impact derived from the normal operation of the Velilla coal-fired power plant. The project where this assessment was performed is part of a bigger project which is jointly developed by the Unit of Radiation Protection of the Public and the Environment (UPRPYMA) of CIEMAT and the Environmental Radioactivity Laboratory of the Extremadura University (LARUEX) in agreement with the Spanish Association of the Electrical Industry (ENUSA). (Author)

  12. Radiological Impact Study of the Coal-Fired Power Plant of Lada; Estudio del Impacto Radiologico de la Central Termica de Carbon de Lada

    Energy Technology Data Exchange (ETDEWEB)

    Robles, B.; Baeza, A.; Mora, J. C.; Corbacho, J. A.; Trueba, C.; Guillen, J.; Rodriguez, J.; Miralles, Y.

    2014-02-01

    Coal, fuel used in thermal power plants for electricity production, contains variable concentrations of naturally occurring radionuclides from natural disintegration series of 238{sup U}, 235{sup U}, 232{sup T}h and also the 40K, which are enhanced in the wastes and coproducts due to the industrial process. For this reason, natural radionuclides which are part of the noncombustible fraction of coal, except those volatiles which incorporate directly to the flue gases, concentrates and are partitioned between fly ashes and bottom ashes. This enhancement could cause, to the workers of the installation and to members of the public around the plant, an increase in the exposure which should be assessed under the radiation protection point of view. Present report collect the results obtained from a screening assessment of the radiological impact derived from the normal operation of the Lada coal-fired power plant. The project where this assessment was performed is part of a bigger project which is jointly developed by the Unit of Radiation Protection of the Public and the Environment (UPRPYMA) of CIEMAT and the Environmental Radioactivity Laboratory of the Extremadura University (LARUEX) in agreement with the Spanish Association of the Electrical Industry (ENUSA). (Author)

  13. Radiological Impact Study of the Coal-Fired Power Plant of Abono; Estudio del Impacto Radiologico de la Central Termica de Carbon de Abono

    Energy Technology Data Exchange (ETDEWEB)

    Robles, B.; Baeza, A.; Mora, J. C.; Corbacho, J. A.; Trueba, C.; Guillen, J.; Rodriguez, J.; Miralles, Y.

    2014-04-01

    Coal, fuel used in thermal power plants for electricity production, contains variable concentrations of naturally occurring radionuclides from natural disintegration series of {sup 2}38U, {sup 2}35U, {sup 2}32Th and also the {sup 4}0K, which are enhanced in the wastes and coproducts due to the industrial process. For this reason, natural radionuclides which are part of the noncombustible fraction of coal, except those volatiles which incorporate directly to the flue gases, concentrates and are partitioned between fly ashes and bottom ashes. This enhancement could cause, to the workers of the installation and to members of the public around the plant, an increase in the exposure which should be assessed under the radiation protection point of view. Present report collect the results obtained from a screening assessment of the radiological impact derived from the normal operation of the Abono coal-fired power plant. The project where this assessment was performed is part of a bigger project which is jointly developed by the Unit of Radiation Protection of the Public and the Environment (UPRPYMA) of CIEMAT and the Environmental Radioactivity Laboratory of the Extremadura University (LARUEX) in agreement with the Spanish Association of the Electrical Industry (ENUSA). (Author)

  14. Radiological Impact Study of the Coal-Fired Power Plant of Anllares; Estudio del Impacto Radiologico de la Central Termica de Carbon de Anllares

    Energy Technology Data Exchange (ETDEWEB)

    Robles, B.; Baeza, A.; Mora, J. C.; Corbacho, J. A.; Trueba, C.; Guillen, J.; Rodriguez, J.; Miralles, Y.

    2014-04-01

    Coal, fuel used in thermal power plants for electricity production, contains variable concentrations of naturally occurring radionuclides from natural disintegration series of {sup 2}38U, {sup 2}35U, {sup 2}32Th and also the 40K, which are enhanced in the wastes and coproducts due to the industrial process. For this reason, natural radionuclides which are part of the noncombustible fraction of coal, except those volatiles which incorporate directly to the flue gases, concentrates and are partitioned between fly ashes and bottom ashes. This enhancement could cause, to the workers of the installation and to members of the public around the plant, an increase in the exposure which should be assessed under the radiation protection point of view. Present report collect the results obtained from a screening assessment of the radiological impact derived from the normal operation of the Anllares coal-fired power plant. The project where this assessment was performed is part of a bigger project which is jointly developed by the Unit of Radiation Protection of the Public and the Environment (UPRPYMA) of CIEMAT and the Environmental Radioactivity Laboratory of the Extremadura University (LARUEX) in agreement with the Spanish Association of the Electrical Industry (ENUSA). (Author)

  15. Radiological Impact Study of the Coal-Fired Power Plant of Meirama; Estudio del Impacto Radiologico de la Central Termica de Carbon de Meirama

    Energy Technology Data Exchange (ETDEWEB)

    Robles, B.; Baeza, A.; Mora, J. C.; Corbacho, J. A.; Trueba, C.; Guillen, J.; Rodriguez, J.; Miralles, Y.

    2014-04-01

    Coal, fuel used in thermal power plants for electricity production, contains variable concentrations of naturally occurring radionuclides from natural disintegration series of {sup 2}38U, {sup 2}35U, {sup 2}32Th and also the 40K, which are enhanced in the wastes and coproducts due to the industrial process. For this reason, natural radionuclides which are part of the noncombustible fraction of coal, except those volatiles which incorporate directly to the flue gases, concentrates and are partitioned between fly ashes and bottom ashes. This enhancement could cause, to the workers of the installation and to members of the public around the plant, an increase in the exposure which should be assessed under the radiation protection point of view. Present report collect the results obtained from a screening assessment of the radiological impact derived from the normal operation of the Meirama coal-fired power plant. The project where this assessment was performed is part of a bigger project which is jointly developed by the Unit of Radiation Protection of the Public and the Environment (UPRPYMA) of CIEMAT and the Environmental Radioactivity Laboratory of the Extremadura University (LARUEX) in agreement with the Spanish Association of the Electrical Industry (ENUSA). (Author)

  16. Reaching an agreement to build a new coal-fired power plant near a national park by mitigating potential environmental impacts

    International Nuclear Information System (INIS)

    Miller, R.L.; Ruppel, T.C.; Evans, E.W.; Heintz, S.J.

    1994-01-01

    This paper presents an interesting example of compromise through comprehensive environmental analysis and intensive negotiation to build a coal-fired power plant near an environmentally sensitive area. In December 1993, the US Department of Energy (DOE) completed the final environmental impact statement (EIS) for the Healy clean Coal Project (HCCP), a proposed demonstration project that would be cost- shared by DOE and the Alaska Industrial Development and Export Authority (AIDEA). The HCCP would be built adjacent to the existing coal-fired Golden Valley Electric Association, Inc. (GVEA) Unit No. 1 in Healy, Alaska, about 4 miles north of Denali National Park and Preserve (DNPP). In response to US Department of the Interior (DOI) concerns about potential air quality related impacts on DNPP, DOE facilitated negotiations among DOE, AIDEA, and GVEA which overcame a ''stalemate'' situation. A Memorandum of Agreement was signed by all four parties, enabling DOI to withdraw its objections. The cornerstone of the Agreement is the planned retrofit of Unit No. 1 to reduce emissions of sulfur dioxide and oxides of nitrogen. If the demonstration technologies operate as expected, combined emissions from the Healy site would increase by only about 8% but electrical generation would triple. The Agreement is a ''win/win'' outcome: DOE can demonstrate the new technologies, AIDEA can build a new power plant for GVEA to operate, and DOE can safeguard the pristine environment DNPP

  17. Economic and ecological assessment of impact of construction and operation of nuclear power plant as large capital construction project with respect to control of national economy development

    International Nuclear Information System (INIS)

    Bucek, M.

    1984-01-01

    The evaluation of costs and environmental impacts of the construction and operation of nuclear power plants is concentrated into two problem areas: 1. the calculation of capital and operation costs for the prevention and minimization of envirommental damage and restoration of the environment, 2. the calculation of damage to the environment of nuclear power plant construction and operation. The ecological cost benefit of capital costs is assessed. In Czechoslovakia there does not exist any method for converting cost effectiveness of investments into environmental protection. This problem is incorporated in the general method of assessing capital cost benefit. The relations are given for total socio-economic capital cost benefit and cost benefit of investments into environmental protection. Ecological investment is not exempted from the investment fund and from the point of view of content may be devided into net and gross ecological investment and from the point of view of time into preventive and compensation ecological investment. In the USSR the method has beem developed of the ecological and economic evaluation of projects for the construction and reconstruction of production units which proceeds from the evaluation of the negative environmental impact of wastes. The basic relations are given of the benefit of ecological investments. (E.S.)

  18. Operation and maintenance of nuclear power plants

    International Nuclear Information System (INIS)

    Ackermann, G.

    1987-01-01

    This textbook gives a systematic introduction into the operational and maintenance activities in nuclear power plants with pressurized water reactors. Subjects: (1) Setup and operational behaviour of power reactors, (2) setup of nuclear power plants, (3) radiation protection and nuclear safety, (4) nuclear fuel, (5) constructional layout of nuclear power plants, (6) management, and (7) maintenance. 158 figs., 56 tabs

  19. Wind Power: Building and Connecting Large Wind Power Plants; Vindkraft: bygga och ansluta stoerre vindkraftverk

    Energy Technology Data Exchange (ETDEWEB)

    2007-09-15

    This brochure is written for those who want to build a large wind power plant (1 MW or more) or wind power parks. It describes the process from idea to completed plant. A review of environmental impacts of wind power is also included

  20. Plant diagnostics in power stations

    International Nuclear Information System (INIS)

    Sturm, A.; Doering, D.

    1985-01-01

    The method of noise diagnostics is dealt with as a part of plant diagnostics in nuclear power stations. The following special applications are presented: (1) The modular noise diagnostics system is used for monitoring primary coolant circuits and detecting abnormal processes due to mechanical vibrations, loose parts or leaks. (2) The diagnostics of machines and plants with antifriction bearings is based on bearing vibration measurements. (3) The measurement of the friction moment by means of acoustic emission analysis is used for evaluating the operational state of slide bearings