WorldWideScience

Sample records for power 80w ktp

  1. Theoretical and experimental study on the Nd:YAG/BaWO4/KTP yellow laser generating 8.3 W output power.

    Science.gov (United States)

    Cong, Zhenhua; Zhang, Xingyu; Wang, Qingpu; Liu, Zhaojun; Chen, Xiaohan; Fan, Shuzhen; Zhang, Xiaolei; Zhang, Huaijin; Tao, Xutang; Li, Shutao

    2010-06-07

    A diode-side-pumped actively Q-switched intracavity frequency-doubled Nd:YAG/BaWO(4)/KTP Raman laser is studied experimentally and theoretically. Rate equations are used to analyze the Q-switched yellow laser by considering the transversal distributions of the intracavity photon density and the inversion population density. An 8.3 W 590 nm laser is obtained with a 125.8 W 808 nm pump power and a 15 kHz pulse repetition frequency. The corresponding optical conversion efficiency from diode laser to yellow laser is 6.57%, much higher than that of the former reported side-pumped yellow laser. The output powers with respect to the incident pump power are in agreement with the theoretical results on the whole.

  2. Efficient high-peak-power and high-repetition-rate eye-safe laser using an intracavity KTP OPO

    International Nuclear Information System (INIS)

    Guo, J; Jiao, Z X; Wang, B; He, G Y

    2015-01-01

    An efficient high-peak-power and high-repetition-rate intracavity KTP optical parametric oscillator pumped by a Q-switched Nd:YVO 4 laser is demonstrated. We achieved 1.5 W output power of 1.5 μm at 10 kHz repetition rate with the pulse duration of 6 ns. The maximum peak power of 25 kW and the maximum pulse energy of 150 μJ have been obtained. The maximum conversion efficiency of 9.5% is achieved with respect to a laser diode power of 10.5 W. (paper)

  3. [KTP (green light) laser for the treatment of benign prostatic hyperplasia. Preliminary evaluation].

    Science.gov (United States)

    Coz, Fernando; Domenech, Alfredo

    2007-09-01

    Photoselective vaporization of benign prostatic hyperplasia (BPH) is a minimally invasive technique, consisting of vaporization of prostatic tissue by KTP green light laser with a power of 80 W. The purpose of this study was to describe our experience with this technique. KTP laser photoselective vaporization was performed in 18 patients, with lower obstructive uropathy secondary to benign prostatic hyperplasia at Santiago Military hospital from December 2005. Preoperative characteristics, postoperative results and complications were recorded. Mean prostatic volume was 55 cc (range: 24 to 78). Mean operating time was 83 minutes (range: 40 to 120). In sixteen patients, the Foley catheter was removed before 24 hours. The mean preoperative AUA score was 22 and decreased to 11.4 after 30 days. The mean maximum preoperative urine flow rate was 9 ml/s and increased to 18.2; 22.1; 22.5; 25.3 and 27.2 ml/s on days 1, 7, 14, 21 and 30, respectively. Only minor complications were observed: delayed removal of the Foley catheter (11.1%), dysuria (16.6%) and late haematuria (11.1%). KTP laser photoselective vaporization of BPH is a safe technique, that is easy to learn, with good short-term functional results, associated with low complication rate.

  4. Comparison of a novel high-power blue diode laser (λ=442 nm) with Ho:YAG (λ=2100 nm), Tm fiber (λ=1940 nm), and KTP (λ=532 nm) lasers for soft tissue ablation

    Science.gov (United States)

    Vinnichenko, Victoriya; Kovalenko, Anastasiya; Arkhipova, Valeriya; Yaroslavsky, Ilya; Altshuler, Gregory; Gapontsev, Valentin

    2018-02-01

    Three lasers were directly compared, including the Ho:YAG laser (λ = 2100 nm), Tm fiber laser (λ = 1940 nm) operating in 3 different modes (CW, regular pulse, and super pulse), and blue diode laser (λ = 442 nm) for vaporization and coagulation efficiency for treating blood-rich soft tissues, ex vivo, in a porcine kidney model at quasi-contact cutting in water. In addition, experimental results were compared with published data on performance of KTP laser (λ = 532 nm) at similar experimental settings (Power = 60 W and cutting speed = 2 mm/s). Tm fiber laser in pulsed mode and blue laser produced highest vaporization rates of 3.7 and 3.4 mm3/s, respectively. Tm fiber laser (in both CW and pulsed modes) also produced the largest coagulation zone among the laser sources tested. A carbonization zone was observed for Tm fiber laser in CW and pulsed modes, as well as for the blue diode laser. Tm fiber laser in super-pulse mode and Ho:YAG laser both resulted in irregular coagulation zones without carbonization. Comparison with known data for KTP laser revealed that tissue effects of the blue laser are similar to that of the KTP laser. These results suggest that the combination of the two lasers (Tm fiber and blue diode) in one system may achieve high cutting efficiency and optimal coagulation for hemostasis during surgical treatment. Ex vivo testing of the combined system revealed feasibility of this approach. The combination of the CW Tm fiber laser (120W) and the blue diode laser (60W) emitting through a combination tip were compared with CW 120 W Tm fiber laser alone and 120 W Ho:YAG laser. Vaporization rates measured 34, 28, and 6 mm3/s, and coagulation zones measured 0.6, 1.3, and 1.7 mm, respectively. A carbonization zone was only observed with CW Tm fiber laser. The vaporization rate of combined CW Tm fiber laser / blue diode laser was comparable to published data for KTP laser for equivalent total power. Thus, high-power blue diode laser, Tm fiber laser, and

  5. Analysis of shade, temperature and hydrogen peroxide concentration during dental bleaching: in vitro study with the KTP and diode lasers.

    Science.gov (United States)

    Fornaini, C; Lagori, G; Merigo, E; Meleti, M; Manfredi, M; Guidotti, R; Serraj, A; Vescovi, P

    2013-01-01

    Many dental bleaching techniques are now available, several of them using a laser source. However, the literature on the exact role of coherent light in the biochemical reaction of the whitening process is very discordant. The aims of this in vitro study were: (1) to compare two different laser sources, a KTP laser with a wavelength of 532 nm and a diode laser with a wavelength of 808 nm, during dental bleaching, and (2) to investigate the relationships among changes in gel temperature, tooth shade and hydrogen peroxide (HP) concentration during laser irradiation. Altogether, 116 bovine teeth were bleached using a 30% HP gel, some of them with gel only and others with gel plus one of the two lasers (532 or 808 nm) at two different powers (2 and 4 W). The KTP laser produced a significant shade variation with a minimal temperature increase. The diode laser led to a higher temperature increase with a greater reduction in HP concentration, but the change in shade was only statistically significant with a power of 4 W. At a power of 2 W, the KTP laser caused a greater change in shade than the diode laser. No significant correlations were found among temperature, HP concentration and shade variation. The KTP laser appears to provide better results with less dangerous thermal increases than the diode laser. This might call into question most of the literature affirming that the action of laser bleaching is by increasing the gel temperature and, consequently, the speed of the redox reaction. Further study is required to investigate the correlations between the parameters investigated and efficacy of the bleaching process.

  6. Efficient diode-end-pumped actively Q-switched Nd:YAG/SrWO4/KTP yellow laser.

    Science.gov (United States)

    Cong, Zhenhua; Zhang, Xingyu; Wang, Qingpu; Liu, Zhaojun; Li, Shutao; Chen, Xiaohan; Zhang, Xiaolei; Fan, Shuzhen; Zhang, Huaijin; Tao, Xutang

    2009-09-01

    An efficient intracavity frequency-doubled Raman laser was obtained by using an SrWO(4) Raman medium, an Nd:YAG ceramic gain medium, and a KTP frequency-doubling medium. Three laser cavities, including a two-mirror cavity, a three-mirror coupled cavity, and a folded cavity, were investigated. With the coupled cavity, a 2.93 W, 590 nm laser was obtained at an incident pump power of 16.2 W and a pulse repetition frequency of 20 kHz; the corresponding conversion efficiency was 18.1%. The highest conversion efficiency of 19.2% was obtained at an incident pump power of 14.1 W and a pulse repetition frequency of 15 kHz. The obtained maximum output power and conversion efficiency were much higher than the results previously obtained with intracavity frequency-doubled solid-state Raman lasers.

  7. 78 FR 28627 - TA-W-80,340; TA-W-80,340A; TA-W-80,340B

    Science.gov (United States)

    2013-05-15

    ...] Bush Industries, Inc., Mason Drive Facility, Including On-Site Leased Workers From Morris Security...., Mason Drive Facility, Jamestown, New York (TA-W-80,340) and Bush Industries, Inc., Allen Street Facility... applicable to TA-W-80,340 is hereby issued as follows: All workers of Bush Industries, Inc., Mason Drive...

  8. EFEKTIVITAS PEMBUATAN KTP DENGAN PROGRAM SISTEM INFORMASI ADMINISTRASI KEPENDUDUKAN (SIAK

    Directory of Open Access Journals (Sweden)

    Ni Luh Putu Suciptawati

    2012-11-01

    Full Text Available KTP is formal ID card Indonesian people which provided by government official. Thisresearch aimed to know efectivity KTP production by SIAK program. Data that used in thisresearch were quantity KTP request 6 years before and 6 years after SIAK program used.Data were analysed using t-student test. The result showed KTP production by SIAK programmost effective.

  9. Solar-pumped 80 W laser irradiated by a Fresnel lens.

    Science.gov (United States)

    Ohkubo, Tomomasa; Yabe, Takashi; Yoshida, Kunio; Uchida, Shigeaki; Funatsu, Takayuki; Bagheri, Behgol; Oishi, Takehiro; Daito, Kazuya; Ishioka, Manabu; Nakayama, Yuichirou; Yasunaga, Norihito; Kido, Kouichirou; Sato, Yuji; Baasandash, Choijil; Kato, Kiyoshi; Yanagitani, Takagimi; Okamoto, Yoshiaki

    2009-01-15

    A solar-pumped 100 W class laser that features high efficiency and low cost owing to the use of a Fresnel lens and a chromium codoped neodymium YAG ceramic laser medium was developed. A laser output of about 80 W was achieved with combination of a 4 m(2) Fresnel lens and a pumping cavity as a secondary power concentrator. This output corresponds to 4.3% of conversion efficiency from solar power into laser, and the maximum output from a unit area of Fresnel lens was 20 W/m(2), which is 2.8 times larger than previous results with mirror-type concentrator.

  10. Ab-initio investigation of Rb substitution in KTP single crystal

    Science.gov (United States)

    Ghoohestani, Marzieh; Arab, Ali; Hashemifar, S. Javad; Sadeghi, Hossein

    2018-01-01

    The effects of rubidium doping on the structural, electronic, and optical properties of KTiOPO4 (KTP) are investigated in the framework of density functional theory. The equilibrium structural parameters of KTP and RbTiOPO4 (RTP) are calculated within the local density and Perdew-Burke-Ernzerhof (PBE), Wu-Cohen, and PBEsol formulation of generalized gradient approximations. We discuss that PBEsol predicts better equilibrium parameters for the KTP alloy. In addition, the variation of lattice constants and Ti-O-Ti bond angles are evaluated as a function of rubidium concentration. The modern modified Becke-Johnson functional is applied for more accurate band gap determination in the pure and alloyed KTP/RTP compounds. The phenomenological pseudoinversion parameter is calculated for a qualitative understanding of the effect of impurity on a non-linear optical response of KTP. We also analyze the behavior of the dielectric function, dispersive refractive indices, and birefringence of KTP/RTP alloys.

  11. Prospective study of the 532 nm laser (KTP) versus diode laser 980 nm in the resection of hyperplastic lesions of the oral cavity

    Science.gov (United States)

    Bargiela-Pérez, Patricia; González-Merchán, Jorge; Díaz-Sánchez, Rosa; Serrera-Figallo, Maria-Angeles; Volland, Gerd; Joergens, Martin; Gutiérrez-Pérez, Jose-Luis

    2018-01-01

    Background The aim of this study is to evaluate the resection of hyperplastic lesions on the buccal mucosa comparing the 532nm laser (KTP), versus diode 980nm laser, considering pain, scarring, inflammation and drug consumption that occurred postoperatively with each lasers. Material and Methods A prospective study of consecutive series of 20 patients in two groups that presents hyperplastic lesions on the buccal mucosa. The choice of the KTP laser or diode 980nm laser for the surgery was made randomly. The power used was 1.5W in both groups in a continuous wave mode with a 320 μm optical fiber. Parameters of pain, scarring, inflammation and consumption of drugs were recorded by a Numerical Rating Scale and evaluated postoperatively. These recordings were made the day of the surgery, 24 hours after, 14 and 28 days after. Results Pain and inflammation was light - moderate. The consumption of paracetamol was somewhat higher in the diode 980nm laser versus the KTP laser after 24 hours, although data was not statistically significant; significant differences were found after 28 days in regards to pain (p = 0.023) and inflammation (p = 0.023), but always in the absence parameter so we find no pain in both lasers. Scarring in the two types of laser showed no differences along the visits, with not detected scar retractable. Conclusions Although there is a slight histological difference regarding the KTP laser in the oral soft tissues for clinical use, both wavelengths are very suitable for excision of oral fibroma. Key words:Laser surgery, Laser therapy, oral surgery, soft tissue, 980 nm diode laser, 532 nm KTP laser. PMID:29274158

  12. The effect of the KTP laser on smear layer and temperature change: an in vitro study.

    Science.gov (United States)

    Arslan, Dilara; Kuştarcı, Alper

    2018-01-01

    The purpose of this study was to evaluate the effects of potassium-titanyl-phosphate (KTP) laser irradiation on smear layer removal and temperature changes of the root surfaces. Two hundred four extracted single-root human premolars were included. The canals were instrumented and divided into two main groups: group A (smear layer examination n:119) and group B (temperature change examination n:85). Each group was divided into subgroups (n:17) according to the different five laser power settings: A1, B1: 1 W-5.33 J/cm 2 ; A2, B2: 1.5 W-7.52 J/cm 2 ; A3, B3: 2 W-10.3 J/cm 2 ; A4, B4: 3 W-15.5 J/cm 2 , A5, B5: 4 W-20.1 J/cm2, A6: positive control no laser irradiation-irrigated 2 mL for 2 min 2.5% NaOCl + 2 mL distilled water and A7: negative control groups no laser irradiation irrigated 2 mL for 2 min 17% EDTA + 2 mL for 2 min 2.5% NaOCl + 2 mL distilled water. The temperature elevations were measured with an infrared thermographic camera and smear layer examined by scanning electron microscope. According to Kruskal-Wallis and Tukey's tests, in all groups the highest smear scores were in the apical third. In all areas, there were statistically significant differences between negative control group (17% EDTA) and all other groups (p laser and positive control (2.5% NaOCl) groups. Statistically, in all thirds, the differences the 3 W and 4 W KTP laser groups between each other and all other groups were significant (p laser, increase in temperature values in all groups were found to be below 10 °C in 20 s.

  13. Photocoagulation of microvascular and hemorrhagic lesions of the vocal fold with the KTP laser.

    Science.gov (United States)

    Hirano, Shigeru; Yamashita, Masaru; Kitamura, Morimasa; Takagita, Shin-ichi

    2006-04-01

    Ectasias and varices of the vocal fold are microvascular lesions that are often due to chronic abuse of the voice, and are occasionally encountered in association with other disorders such as polyps, Reinke's edema, and hematoma. The KTP laser can be used for photocoagulation of small vascular lesions, because the laser beam is well absorbed by hemoglobin, and damage to the epithelium is minimal. The present pilot study examined how the KTP laser could be used for microvascular lesions and their associated lesions. Twelve patients who had undergone phonomicrosurgery were enrolled in the present study. The microvascular lesions were treated by photocoagulation with the laser set at a low power of 1.5 W in the continuous mode, while preserving the epithelium, and associated lesions were then treated by microdissection with cold instruments. The postoperative phonatory function was assessed by maximum phonation time, a perceptual test rating (GRBAS scale), and stroboscopy. The procedures were completed successfully in all cases. An exceptional case of a small hemorrhagic polyp allowed treatment with the laser only. The postoperative stroboscopic findings, maximum phonation time, and perceptual test rating all showed significant improvement compared with the preoperative state. No adverse effects, such as scarring or reduction of the mucosal wave, were observed in the current series. KTP laser photocoagulation is a relatively simple and safe procedure for treating microvascular lesions of the vocal fold. It is not recommended for photocoagulation of hemorrhagic polyps or hematomas, because such lesions have little blood flow inside and thus photocoagulation is usually impossible or requires too much laser energy. However, photocoagulation of perimeter or feeding vessels of such disorders may facilitate the following procedure by avoiding unnecessary bleeding, as well as preventing recurrence of hemorrhagic lesions.

  14. KOORDINASI ANTAR LEMBAGA PEMERINTAH DALAM PELAYANAN E-KTP DI KECAMATAN RAPPOCINI KOTA MAKASSAR

    Directory of Open Access Journals (Sweden)

    Nurhidayat M

    2013-10-01

      Penelitian ini bertujuan Untuk mengetahui Koordinasi Antar Lembaga Pemerintahan Dalam Pelayanan E- KTP serta untuk mengetahui faktor-faktor yang menjadi pendukung dan penghambat Koordinasi Antar Lembaga Pemerintah Dalam Pelayanan E-KTP di Kecamatan Rappocini Kota Makassar. Penelitian ini adalah Deskriptif-Kualitatif, Populasi dalam penelitian sekaligus merupakan sampel sebanyak 31 orang. Data dikumpulkan dengan menggunakan teknik berupa observasi, kuesioner serta dikembangkan dengan wawancara kepada responden. Data tersebut dianalisis secara Deskriptip kualitatif yaitu menganalisis semua data yang berhasil dikumpulkan penulis, dan selanjutnya disajikan dalam bentuk tabulasi frekuensi dilengkapi dengan tanggapan responden yang diperoleh dari hasil Informan, wawancara, dan kuesioner. Hasil penelitian menunjukkan Koordinasi Antar Lembaga Pemerintah dalam pelayanan e-KTP di Kecamatan Rappocini Kota Makassar dikategorikan kurang efektif dan dipengaruhi oleh beberapa faktor pendukung dan penghambat. Adapun Faktor penghambat dalam Pelayanan e-KTP yaitu : (a.Kurangnya sarana dan prasaranan perangkat komputer di banding jumlah wajib e-KTP. (b.Rendahnya peran aktif masyarakat ikut antrian dalam pelayanan e-KTP. (c.Kurang proposionalnya operator e-KTP dalam melaksanakan tugas dan tanggung jawab. Sedangkan yang menjadi faktor pendukung dalam pelayanan e-KTP yaitu : (a.Adanya regulasi tentang kebijakan kependudukan dalam pelayanan e-KTP, (b. Adanya anggaran APBD yang proposional dari pemerintah pusat untuk distribusikan setiap Kecamatan yang ada di Kota Makassar.

  15. Diode-side-pumped intracavity frequency-doubled Nd:YAG/BaWO4 Raman laser generating average output power of 3.14 W at 590 nm.

    Science.gov (United States)

    Li, Shutao; Zhang, Xingyu; Wang, Qingpu; Zhang, Xiaolei; Cong, Zhenhua; Zhang, Huaijin; Wang, Jiyang

    2007-10-15

    We report a linear-cavity high-power all-solid-state Q-switched yellow laser. The laser source comprises a diode-side-pumped Nd:YAG module that produces 1064 nm fundamental radiation, an intracavity BaWO(4) Raman crystal that generates a first-Stokes laser at 1180 nm, and a KTP crystal that frequency doubles the first-Stokes laser to 590 nm. A convex-plane cavity is employed in this configuration to counteract some of the thermal effect caused by high pump power. An average output power of 3.14 W at 590 nm is obtained at a pulse repetition frequency of 10 kHz.

  16. Treatment of extensive urethral hemangioma with KTP/532 laser.

    Science.gov (United States)

    Lauvetz, R W; Malek, R S; Husmann, D A

    1996-01-01

    Urethral hemangiomas are rare. They vary in size from pinpoint masses to extensive honeycomb-shape deformities leading to significant hematuria. For extensive lesions, therapeutic options have included extensive surgical resection and reconstruction or multistaged neodymium:yttrium-aluminum-garnet (Nd:YAG) laser photocoagulation. We report our experience with the use of potassium titanyl phosphate (KTP/532) laser for treatment of the extensive form. A 7-year-old boy presented with a 2-week history of urethral bleeding. He had extensive hemangiomas of the genital and perineal regions. Cystourethroscopy disclosed diffusely scattered honeycomb-shape hemangiomatous malformation of the anterior urethra. KTP/532 laser energy was delivered transurethrally to the hemangiomatous areas until they blanched. The Foley catheter was removed 24 hours postoperatively, and the patient voided clear urine without difficulty. He has remained trouble-free for more than 2 years. Judicious endoscopic single-stage therapy with KTP/532 laser may obviate open surgical intervention in most cases of extensive and symptomatic urethral hemangiomas. In view of our observation and the literature, KTP/532 laser therapy should be considered the first line of treatment.

  17. Critical Discourse Analysis towards Authority Ideology "Case of Mega Corruption E-KTP (Electronic ID Card " in Tempo Magazine

    Directory of Open Access Journals (Sweden)

    Martono Martono

    2018-03-01

    Full Text Available The ideology that is reflected in the discourse of Tempo Magazine in 2017 'the case of Mega Corruption e-KTP is seen from the text structure which includes the macrostructure. The global meanings studied are interrelated. The data obtained by journalists are used to discuss the topic of e-KTP case. "Fireball Corruption KTP". Superstructure discourse discussed based on the introduction, the contents, the cover, but not found conclusions. The preliminary section described has always supported the title of the discourse. The content section is the focus of journalist's study on e-KTP corruption issues. The closing section used by journalists always gives a settlement of the news presented. The microstructure of the discourse uses effective, straightforward and diction sentences. Ideology is seen from social cognition. There is a linkage of texts that journalists describe with the community. All perceptions and actions, and ultimately the production and interpretation of this discourse are based on the mental representation of every event that takes place. Events are presented based on a lot of evidence and believed to be true. Ideology is seen from the social context that includes the practice of power and access to affect the discourse. The practice of power in the discourse on the topic of mega corruption is related to the members of the People's Legislative Assembly and the Chief Judge of the Court. The Chief Justice used his power to reprimand the accused. Judging from the access that influences discourse then found a character who can use and or influence the discourse.

  18. Ab- initio investigation of physical properties of KTP and RTP

    Directory of Open Access Journals (Sweden)

    Marzieh Ghoohestani

    2017-09-01

    Full Text Available In this work,the physical properties of  KTP and RTP single-crystals have been investigated by performing accurate total energy calculations in the framework of density functional theory by using the full-potential linearized augmented plane wave method. The effects of Rb substitution on structural, electronic and optical properties of KTP are discussed. The structural properties have been calculated by using different exchange correlation including LDA, PBE, WC and PBEsol. Also PBEsol approximation and and more accurate approximation mBJ are employed to calculate the energy gap values. The Pseudoinversion values of both crystals have been calculated by using PseudoSymmetry software . Rb substitution effect on pseudosymmetry of KTP and also relation between second-order susceptibility of crystals and the Pseudoinversion values are discussed. The optical coefficients such as refractive index, birefringence values and absorption coefficients have been calculated by using the dielectric function. The anisotropy in the linear optical properties of KTP and RTP crystals have been demonstrated. Then calculated results have been compared.

  19. Blue 450nm high power semiconductor continuous wave laser bars exceeding rollover output power of 80W

    Science.gov (United States)

    König, H.; Lell, A.; Stojetz, B.; Ali, M.; Eichler, C.; Peter, M.; Löffler, A.; Strauss, U.; Baumann, M.; Balck, A.; Malchus, J.; Krause, V.

    2018-02-01

    Industrial material processing like cutting or welding of metals is rather energy efficient using direct diode or diode pumped solid state lasers. However, many applications cannot be addressed by established infrared laser technology due to fundamental material properties of the workpiece: For example materials like copper or gold have too low absorption in the near infrared wavelength range to be processed efficiently by use of existing high power laser systems. The huge interest to enable high power kW systems with more suitable wavelengths in the blue spectral range triggered the German funded research project 'BLAULAS': Therein the feasibility and capability of CW operating high power laser bars based on the GaN material system was investigated by Osram and Laserline. High performance bars were enabled by defeating fundamental challenges like material quality as well as the chip processes, both of which differ significantly from well-known IR laser bars. The research samples were assembled on actively cooled heat sinks with hard solder technology. For the first time an output power of 98W per bar at 60A drive current was achieved. Conversion efficiency as high as 46% at 50W output power was demonstrated.

  20. Development of 360-W LD pumped Nd:YAG amplifier with a phase conjugation mirror

    International Nuclear Information System (INIS)

    Kiriyama, Hiromitsu; Nagai, Toru; Yamakawa, Koichi; Kageyama, Nobuto; Miyajima, Hirofumi; Kan, Hirofumi; Yoshida, Hidetsugu; Nakatsuka, Masahiro

    2004-01-01

    We report on a high-average-power laser-diode (LD) pumped Nd:YAG master-oscillator-power-amplifier (MOPA) system with a minimum number of element for the single multi-pass zigzag-slab amplifier-stage for pumping of a high-peak and high-average power Ti:sapphire laser system. This phase conjugated system produces an average-power of 362 W at 1 kHz in a 30 ns pulse with an optical-to-optical conversion efficiency of 14%. With an external KTP doubler, this system generates 132 W of green average-output-power at 1 kHz with a conversion efficiency of 60% when pumped at a power level of 222 W. To the best of our knowledge, these results represent the highest average-output-power at both infrared and green wavelengths achieved in a single-amplifier-stage. (author)

  1. Implementasi aplikasi kehadiran perkuliahan dikelas menggunakan pembaca RFID pada e-KTP

    Directory of Open Access Journals (Sweden)

    Muhamad Akbar

    2018-01-01

    Full Text Available This research was conducted to help the process of teaching and learning in the classroom by utilizing the information obtained from class attendance e-KTP reader. E-ID card now has a chip that can be used and owned by students to solve class attendance problem. In this research, information that obtained from e-KTP is used as application input. This research built an application that can read the information saved in the e-KTP chip card, then used as the student class attendance counter. The descriptive and qualitative methodology was used in this research. This research aimed to help the university stakeholder to effectively and efficiently monitor students and lecturers attendance.

  2. InP MMIC Chip Set for Power Sources Covering 80-170 GHz

    Science.gov (United States)

    Ngo, Catherine

    2001-01-01

    We will present a Monolithic Millimeter-wave Integrated Circuit (MMIC) chip set which provides high output-power sources for driving diode frequency multipliers into the terahertz range. The chip set was fabricated at HRL Laboratories using a 0.1-micrometer gate-length InAlAs/InGaAs/InP high electron mobility transistor (HEMT) process, and features transistors with an f(sub max) above 600 GHz. The HRL InP HEMT process has already demonstrated amplifiers in the 60-200 GHz range. In this paper, these high frequency HEMTs form the basis for power sources up to 170 GHz. A number of state-of-the-art InP HEMT MMICs will be presented. These include voltage-controlled and fixed-tuned oscillators, power amplifiers, and an active doubler. We will first discuss an 80 GHz voltage-controlled oscillator with 5 GHz of tunability and at least 17 mW of output power, as well as a 120 GHz oscillator providing 7 mW of output power. In addition, we will present results of a power amplifier which covers the full WRIO waveguide band (75-110 GHz), and provides 40-50 mW of output power. Furthermore, we will present an active doubler at 164 GHz providing 8% bandwidth, 3 mW of output power, and an unprecedented 2 dB of conversion loss for an InP HEMT MMIC at this frequency. Finally, we will demonstrate a power amplifier to cover 140-170 GHz with 15-25 mW of output power and 8 dB gain. These components can form a power source in the 155-165 GHz range by cascading the 80 GHz oscillator, W-band power amplifier, 164 GHz active doubler and final 140-170 GHz power amplifier for a stable, compact local oscillator subsystem, which could be used for atmospheric science or astrophysics radiometers.

  3. OPTIMALISASI PELAYANAN PUBLIK DALAM PELAKSANAAN e-KTP GUNA MEMPERKOKOH KETAHANAN WILAYAH (Studi Di Kelurahan Kalibaru Kecamatan Cilodong Kota Depok, Jawa Barat

    Directory of Open Access Journals (Sweden)

    Muhtarhadi Nursalim

    2014-04-01

    Full Text Available This paper explained public service optimization in e-KTP implementation to strengthened regional resilience. The problem showed due the e-KTP implementation less than 100% achievement at the end of 2012. The purpose of this paper was discovering the public service quality condition of the e-KTP implementation in Kalibaru sub-district Cilodong District Depok, identify the obstacle of the e-KTP implementation in Kalibaru sub-district Cilodong District Depok, and establish the public service optimization strategy of the e-KTP implementation in Kalibaru sub-district Cilodong District Depok, and also the implication on regional resilience. The method of this paper was interview and fi eld observation. The location election method is conducted with purposive sampling. The variable of this research was public service optimization of the e-KTP implementation at the Kalibaru sub-district, namely the Organization Structure of the e-KTP Service, Service Administration of the e-KTP Service, human resource of the e-KTP Service, facilities and infrastructure of the e-KTP. The result of this paper showed the strategies to optimized the e-KTP service implementation at Kalibaru sub-District were (a increase the coordination, (b Implementing MSDN functions namely management function and operational. Therefore the e-KTP implementation would be able to supported Regional resilience. Keywords: Public Service, e-KTP, Regional Resilience

  4. Development of a 400 kV 80 mA Cockcroft-Walton power supply and 12 kW isolation transformer systems for neutron generators

    Science.gov (United States)

    Lu, X.; Chen, S.; Zhang, Y.; Huang, Z.; Ma, Z.; Yao, Z.

    2017-06-01

    A 400 kV 80 mA Cockcroft-Walton power supply driven by 2.5 kHz frequency, and 12 kW isolation transformer systems are developed for an intense DD/DT neutron generator. The design, construction, and testing of the high voltage (HV) power supply and isolation transformer systems are detailed reported. The structure of step-up transformers can make the potential distribution uniform, and auxiliary coils of the isolation transformers can improve the power transmission efficiency significantly. The testing results show that the HV power supply can reach 400 kV, and the isolation transformer systems can withstand 400 kV voltages and its power transmission efficiency is about 98.1%.

  5. Potassium titanyl phosphate laser-induced inflammatory response and extracellular matrix turnover in rabbit vocal fold scar.

    Science.gov (United States)

    Zhang, Jing; Zhen, Ruiqing; Wei, Chunsheng

    2018-04-02

    The objectives of this study were to observe the regulating effect of KTP laser and Nd:YAG laser in the repair of vocal fold scars. All rabbits were injured in the muscular layer with a sharp instrument, and then the vocal folds were treated with a KTP laser and a Nd:YAG laser at a power of 2, 4, 6 and 8 W 1 month after the injury. One month after treatment, the rabbits were killed and the throats were removed to detect changes in histology and gene expression of the vocal fold scar after laser therapy. The best efficacy of all KTP laser treatment groups was the KTP laser 6 W group. Regarding the detection of gene expression, in the KTP laser 6 W and Nd:YAG laser 6 W groups, col-3A1 was decreased compared to the scar group (P vocal fold scars have particular therapeutic effects. The KTP laser may be better than the Nd:YAG laser for the regulation of vocal fold scars. NA.

  6. 47 CFR 80.215 - Transmitter power.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Transmitter power. 80.215 Section 80.215... MARITIME SERVICES General Technical Standards § 80.215 Transmitter power. (a) Transmitter power shown on the radio station authorization is the maximum power the licensee is authorized to use. Power is...

  7. Pramana – Journal of Physics | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    2014-02-09

    Feb 9, 2014 ... The laser delivers stable dual wavelength cw mode-locked pulse train with pulse duration 10.3 ps and average power of 1.84 W and 255 mW at 1064 nm and 532 nm respectively for the optimum performance in type-II KTP crystal. The exceptional stability achieved with KTP is accounted by simulating the ...

  8. Generation of more than 300 mW diffraction-limited light at 405 nm by second-harmonic generation of a tapered diode laser with external cavity feedback

    DEFF Research Database (Denmark)

    Jensen, Ole Bjarlin; Holm, J.; Sumpf, B.

    2007-01-01

    We have constructed a blue laser source consisting of a single-frequency tapered diode laser with external cavity feedback that is frequency doubled by a quasi-phase matched KTP (PPKTP) in a bowtie ring cavity and extract more than 360 mW of power at 405 nm. The conversion efficiency from...... fundamental laser power to second harmonic power is 35 %, while it is 64 % from coupled fundamental power to extracted blue light. Thermal effects and gray tracking set an upper limit on the amount of generated blue light....

  9. 47 CFR 80.1015 - Power supply.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Power supply. 80.1015 Section 80.1015... MARITIME SERVICES Radiotelephone Installations Required by the Bridge-to-Bridge Act § 80.1015 Power supply. (a) There must be readily available for use under normal load conditions, a power supply sufficient...

  10. The refractive index distributions of KTP crystal waveguides formed with He-ions at high fluences and low energy

    International Nuclear Information System (INIS)

    Yin, Jiao-Jian; Lu, Fei; Ming, Xian-Bing; Ma, Yu-Jie

    2013-01-01

    The 300 keV He + ions have been implanted into z-cut KTP crystals with fluences of 4 × 10 16 , 6 × 10 16 , 8 × 10 16 and 10 × 10 16 ions/cm 2 . The Rutherford back scattering spectrometry (RBS)/channelling spectra of KTP crystals and the dark-mode spectrum have been measured. According to the multiple scattering formulae of Feldman and Rodgers, the damage profiles of z-cut KTP crystals have been calculated and extracted. The relations between the damage ratio, fluence and the ion-implanted depth have been established. The refractive index profiles over depth have been calculated, which are very close to the real distribution in waveguide

  11. 47 CFR 80.917 - Reserve power supply.

    Science.gov (United States)

    2010-10-01

    ... power supply must be adequately treated to prevent freezing or overheating consistent with the season... 47 Telecommunication 5 2010-10-01 2010-10-01 false Reserve power supply. 80.917 Section 80.917... MARITIME SERVICES Compulsory Radiotelephone Installations for Small Passenger Boats § 80.917 Reserve power...

  12. Green bright squeezed light from a cw periodically poled KTP second harmonic generator

    DEFF Research Database (Denmark)

    Andersen, Ulrik Lund; Buchhave, Preben

    2002-01-01

    We present the experimental observation of bright amplitude squeezed light from a singly resonant second harmonic generator (SHG) based on a periodically poled potassium titanyl phosphate (KTP) crystal. Contrary to conventional SHG, the interacting waves in this device couple efficiently using qu...... reduction is greater than what could be expected using normal birefringence phase matched KTP with the same experimental parameters. Excellent agreement between experiment and theory is found. (C)2002 Optical Society of America....... quasi phase matching (QPM) and more importantly QPM allows access to higher valued elements of the nonlinear tensor than is possible under the constraint of birefringence phase matching. We observe a noise reduction of 13% below the shot noise limit in the generated second harmonic field. This noise...

  13. Highly efficient periodically poled KTP-isomorphs with large apertures and extreme domain aspect-ratios

    Science.gov (United States)

    Canalias, Carlota; Zukauskas, Andrius; Tjörnhamman, Staffan; Viotti, Anne-Lise; Pasiskevicius, Valdas; Laurell, Fredrik

    2018-02-01

    Since the early 1990's, a substantial effort has been devoted to the development of quasi-phased-matched (QPM) nonlinear devices, not only in ferroelectric oxides like LiNbO3, LiTaO3 and KTiOPO4 (KTP), but also in semiconductors as GaAs, and GaP. The technology to implement QPM structures in ferroelectric oxides has by now matured enough to satisfy the most basic frequency-conversion schemes without substantial modification of the poling procedures. Here, we present a qualitative leap in periodic poling techniques that allows us to demonstrate devices and frequency conversion schemes that were deemed unfeasible just a few years ago. Thanks to our short-pulse poling and coercive-field engineering techniques, we are able to demonstrate large aperture (5 mm) periodically poled Rb-doped KTP devices with a highly-uniform conversion efficiency over the whole aperture. These devices allow parametric conversion with energies larger than 60 mJ. Moreover, by employing our coercive-field engineering technique we fabricate highlyefficient sub-µm periodically poled devices, with periodicities as short as 500 nm, uniform over 1 mm-thick crystals, which allow us to realize mirrorless optical parametric oscillators with counter-propagating signal and idler waves. These novel devices present unique spectral and tuning properties, superior to those of conventional OPOs. Furthermore, our techniques are compatible with KTA, a KTP isomorph with extended transparency in the mid-IR range. We demonstrate that our highly-efficient PPKTA is superior both for mid-IR and for green light generation - as a result of improved transmission properties in the visible range. Our KTP-isomorph poling techniques leading to highly-efficient QPM devices will be presented. Their optical performance and attractive damage thresholds will be discussed.

  14. 1.2V, 24mW/ch, 10bit, 80MSample/s Pipelined A/D Converters

    Science.gov (United States)

    Ueno, Takeshi; Ito, Tomohiko; Kurose, Daisuke; Yamaji, Takafumi; Itakura, Tetsuro

    This paper describes 10-bit, 80-MSample/s pipelined A/D converters for wireless-communication terminals. To reduce power consumption, we employed the I/Q amplifier sharing technique [1] in which an amplifier is used for both I and Q channels. In addition, common-source, pseudo-differential (PD) amplifiers are used in all the conversion stages for further power reduction. Common-mode disturbances are removed by the proposed common-mode feedforward (CMFF) technique without using fully differential (FD) amplifiers. The converter was implemented in a 90-nm CMOS technology, and it consumes only 24mW/ch from a 1.2V power supply. The measured SNR and SNDR are 58.6dB and 52.2dB, respectively.

  15. Fabrication and Characterization of novel W80Ni10Nb10 alloy produced by mechanical alloying

    Science.gov (United States)

    Saxena, R.; Patra, A.; Karak, S. K.; Pattanaik, A.; Mishra, S. C.

    2016-02-01

    Nanostructured tungsten (W) based alloy with nominal composition of W80Ni10Nb10 (in wt. %) was synthesized by mechanical alloying of elemental powders of tungsten (W), nickel (Ni), niobium (Nb) in a high energy planetary ball-mill for 20 h using chrome steel as grinding media and toluene as process control agent followed by compaction at 500 MPa pressure for 5 mins and sintering at 1500°C for 2 h in Ar atmosphere. The phase evolution and the microstructure of the milled powder and consolidated product were investigated by X-ray diffraction (XRD), Scanning electron microscopy (SEM) and Transmission electron microscopy (TEM). The crystallite size of W in W80Ni10Nb10 powder was reduced from 100 μm at 0 h to 45.6 nm at 10 h and 34.1 nm at 20 h of milling whereas lattice strain increases to 35% at 20 h of milling. The dislocation density shows sharp increase up to 5 h of milling and the rate of increase drops beyond 5 to 20 h of milling. The lattice parameter of tungsten in W80Ni10Nb10 expanded upto 0.04% at 10 h of milling and contracted upto 0.02% at 20 h of milling. The SEM micrograph revealed the presence of spherical and elongated particles in W80Ni10Nb10 powders at 20 h of milling. The particle size decreases from 100 μm to 2 μm with an increase in the milling time from 0 to 20 hours. The crystallite size of W in milled W80Ni10Nb10 alloy as evident from bright field TEM image was in well agreement with the measured crystallite size from XRD. Structure of W in 20 h milled W80Ni10Nb10 alloy was identified by indexing of selected area diffraction (SAD) pattern. Formation of NbNi intermetallic was evident from XRD pattern and SEM micrograph of sintered alloy. Maximum sinterability of 90.8% was achieved in 20 h milled sintered alloy. Hardness and wear study was also conducted to investigate the mechanical behaviour of the sintered product. Hardness of W80Ni10Nb10 alloy reduces with increasing load whereas wear rate increases with increasing load. The evaluated

  16. 47 CFR 80.864 - Emergency electric lights.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Emergency electric lights. 80.864 Section 80... W § 80.864 Emergency electric lights. (a) Emergency electric light(s) must be installed to...) The emergency electric light(s) must be energized from the reserve power supply, if a reserve power...

  17. Decoherence and absorption of Er3+:KTiOPO4 (KTP) at 1.5 μm

    International Nuclear Information System (INIS)

    Böttger, Thomas; Thiel, C.W.; Sun, Y.; Macfarlane, R.M.; Cone, R.L.

    2016-01-01

    We present results of laser absorption spectroscopy and two-pulse photon echo decoherence measurements on the lowest 4 I 15/2 to lowest 4 I 13/2 transition in Er 3+ : KTiOPO 4 (KTP—potassium titanyl phosphate) for the optical transition located at 1537.238 nm. This transition was found to have an inhomogeneous absorption linewidth of 950 MHz and pronounced polarization dependence. Two-pulse photon echo decay measurements as a function of applied magnetic field strength at 1.9 K revealed a narrow homogeneous linewidth of 2.5 kHz at 0.2 T that increased to 5.8 kHz at 1.2 T and then decreased to 1.6 kHz at 4.5 T. This behavior was successfully described by decoherence due to Er 3+ –Er 3+ magnetic dipole interactions. Significant superhyperfine coupling of Er 3+ spins to the nuclear moments of ions in the host lattice was observed, modulating the photon echo decay at low magnetic fields and limiting the effective homogenous linewidth at high fields. Combined with the well-established potential of KTP for fabrication of high-quality optical waveguides and integrated non-linear frequency conversion, our results suggest that Er 3+ :KTP is a promising material system for practical spectral hole burning, signal processing, and quantum information applications. - Highlights: • Bulk Er 3+ :KTP has dominant Er 3+ site at 1537.238 nm with Γ inh of 950 MHz and T 1 of 16.9 ms. • Two-pulse photon echoes revealed magnetic field dependent kHz-wide homogeneous linewidth. • Decoherence modeled using direct-phonon driven Er 3+ –Er 3+ magnetic dipole-dipole interactions. • Evidence of superhyperfine coupling of Er 3+ spins to nuclear moments of host ions. • Er 3+ :KTP is a promising material system for quantum memory and signal processing applications.

  18. Flexible power 90W to 120W ArF immersion light source for future semiconductor lithography

    Science.gov (United States)

    Burdt, R.; Thornes, J.; Duffey, T.; Bibby, T.; Rokitski, R.; Mason, E.; Melchior, J.; Aggarwal, T.; Haran, D.; Wang, J.; Rechtsteiner, G.; Haviland, M.; Brown, D.

    2014-03-01

    Semiconductor market demand for improved performance at lower cost continues to drive enhancements in excimer light source technologies. Increased output power, reduced variability in key light source parameters, and improved beam stability are required of the light source to support immersion lithography, multi-patterning, and 450mm wafer applications in high volume semiconductor manufacturing. To support future scanner needs, Cymer conducted a technology demonstration program to evaluate the design elements for a 120W ArFi light source. The program was based on the 90W XLR 600ix platform, and included rapid power switching between 90W and 120W modes to potentially support lot-to-lot changes in desired power. The 120W requirements also included improved beam stability in an exposure window conditionally reduced by 20%. The 120W output power is achieved by efficiency gains in system design, keeping system input power at the same level as the 90W XLR 600ix. To assess system to system variability, detailed system testing was conducted from 90W - 120W with reproducible results.

  19. Comparison of inter-trial recovery times for the determination of critical power and W' in cycling.

    Science.gov (United States)

    Karsten, Bettina; Hopker, James; Jobson, Simon A; Baker, Jonathan; Petrigna, Luca; Klose, Andreas; Beedie, Christopher

    2017-07-01

    Critical Power (CP) and W' are often determined using multi-day testing protocols. To investigate this cumbersome testing method, the purpose of this study was to compare the differences between the conventional use of a 24-h inter-trial recovery time with those of 3 h and 30 min for the determination of CP and W'. 9 moderately trained cyclists performed an incremental test to exhaustion to establish the power output associated with the maximum oxygen uptake (p[Formula: see text] max ), and 3 protocols requiring time-to-exhaustion trials at a constant work-rate performed at 80%, 100% and 105% of p[Formula: see text] max. Design: Protocol A utilised 24-h inter-trial recovery (CP 24 /W' 24 ), protocol B utilised 3-h inter-trial recovery (CP 3 /W' 3 ), and protocol C used 30-min inter-trial recovery period (CP 0.5 /W' 0.5 ). CP and W' were calculated using the inverse time (1/t) versus power (P) relation (P = W'(1/t) + CP). 95% Limits of Agreement between protocol A and B were -9 to 15 W; -7.4 to 7.8 kJ (CP/W') and between protocol A and protocol C they were -27 to 22 W; -7.2 to 15.1 kJ (CP/W'). Compared to criterion protocol A, the average prediction error of protocol B was 2.5% (CP) and 25.6% (W'), whilst for protocol C it was 3.7% (CP) and 32.9% (W'). 3-h and 30-min inter-trial recovery time protocols provide valid methods of determining CP but not W' in cycling.

  20. Efficient generation of continuous-wave yellow-orange light using sum-frequency in periodically poled KTP

    DEFF Research Database (Denmark)

    Janousek, Jiri; Johansson, Sandra; Tidemand-Lichtenberg, Peter

    We present highly efficient sum-frequency generation between two CW 1064 and 1342 nm laser lines of two Nd:YVO4 lasers using periodically poled KTP. This is an all solid-state light source in the yellow-orange spectral range....

  1. [Experiences in the treatment of benign prostatic hyperplasia with high power potassium-titanyl-phosphate (KTP) laser].

    Science.gov (United States)

    Lipiński, Marek I; Peszyński-Drews, Cezary; Jeromin, Marek Z; Jeromin, Leszek M

    2006-01-01

    Benign prostatic hyperplasia (BPH) exist in about 70% men after 60 years old. High power KTP laser is a new tool for the treatment of BPH. 49 men were treated by photoselective vaporisation of the prostate (PVP) from August 2003 to May 2004. Thirty patients with follow-up period longer than 12 weeks (12 to 26 weeks) were analyzed. Preoperative prostate volume ranged from 31 to 136 cc. PSA range, estimated before treatment, was normal in all patients (pts). International Prostate Symptom Score (I-PSS) estimated before treatment was over 24 and Quality of Life (QoL) was over 3 in all pts. The maximum peak urinary flow (Qmax) before treatment ranged from 7.2 to 14.1 ml/s. One patient was catheterized with Foley catheter at the finish of the procedure. Two pts required catheterization in the first day after treatment. In two pts increasing of body temperature to 38 degrees C was observed in the first day after treatment. Twenty four hours after treatment haematuria required catheterization was observed in one patient. Seven days after treatment in 4 pts massive haematuria was observed (two required hospitalisation). In one patient because of urinary retention 4 weeks after PVP transurethral resection of the prostate was performed. Four weeks after PVP I-PSS decreased from 24 to 20 and after 12 weeks to 15. The Qmax increased and ranged from 11.3 ml/s to 17.1 ml/s 4 weeks after PVP and 12 weeks after PVP ranged from 15.1 to 22.8 ml/s. Photoselective vaporization of the prostate reduces I-PSS in all patients 12 weeks after procedure. Short follow-up period and a limited number of patients in study group cannot lead to ultimate conclusions. However the results encourage to undertaking further studies on PVP for the treatment of BPH.

  2. Threshold for strong thermal dephasing in periodically poled KTP in external cavity frequency doubling

    DEFF Research Database (Denmark)

    Lundeman, Jesper Holm; Jensen, Ole Bjarlin; Andersen, Peter E.

    2009-01-01

    We present a measurement series of the efficiency of periodically poled KTP used for second-harmonic generation in an external phase-locked cavity. Due to the high absorption (0.01 cm^−1) in the PPKTP crystal at the pump wavelength a strong thermal dephasing of the periodically poled grating...

  3. Decoherence and absorption of Er{sup 3+}:KTiOPO{sub 4} (KTP) at 1.5 μm

    Energy Technology Data Exchange (ETDEWEB)

    Böttger, Thomas, E-mail: tbottger@usfca.edu [Department of Physics & Astronomy, University of San Francisco, 2130 Fulton St., San Francisco, CA 94117 (United States); Thiel, C.W. [Department of Physics, Montana State University, Bozeman, MT 59717 (United States); Sun, Y. [Deptartment of Physics, University of South Dakota, Vermillion, SD 57069 (United States); Macfarlane, R.M. [Department of Physics, Montana State University, Bozeman, MT 59717 (United States); IBM Almaden Research Center, 650 Harry Road, San Jose, CA 95120 (United States); Cone, R.L. [Department of Physics, Montana State University, Bozeman, MT 59717 (United States)

    2016-01-15

    We present results of laser absorption spectroscopy and two-pulse photon echo decoherence measurements on the lowest {sup 4}I{sub 15/2} to lowest {sup 4}I{sub 13/2} transition in Er{sup 3+}: KTiOPO{sub 4} (KTP—potassium titanyl phosphate) for the optical transition located at 1537.238 nm. This transition was found to have an inhomogeneous absorption linewidth of 950 MHz and pronounced polarization dependence. Two-pulse photon echo decay measurements as a function of applied magnetic field strength at 1.9 K revealed a narrow homogeneous linewidth of 2.5 kHz at 0.2 T that increased to 5.8 kHz at 1.2 T and then decreased to 1.6 kHz at 4.5 T. This behavior was successfully described by decoherence due to Er{sup 3+}–Er{sup 3+} magnetic dipole interactions. Significant superhyperfine coupling of Er{sup 3+} spins to the nuclear moments of ions in the host lattice was observed, modulating the photon echo decay at low magnetic fields and limiting the effective homogenous linewidth at high fields. Combined with the well-established potential of KTP for fabrication of high-quality optical waveguides and integrated non-linear frequency conversion, our results suggest that Er{sup 3+}:KTP is a promising material system for practical spectral hole burning, signal processing, and quantum information applications. - Highlights: • Bulk Er{sup 3+}:KTP has dominant Er{sup 3+} site at 1537.238 nm with Γ{sub inh} of 950 MHz and T{sub 1} of 16.9 ms. • Two-pulse photon echoes revealed magnetic field dependent kHz-wide homogeneous linewidth. • Decoherence modeled using direct-phonon driven Er{sup 3+}–Er{sup 3+} magnetic dipole-dipole interactions. • Evidence of superhyperfine coupling of Er{sup 3+} spins to nuclear moments of host ions. • Er{sup 3+}:KTP is a promising material system for quantum memory and signal processing applications.

  4. 532 nm continuous wave mode-locked Nd:GdVO4 laser with SESAM

    International Nuclear Information System (INIS)

    Li, L; Liu, J; Liu, M; Liu, S; Chen, F; Wang, W; Wang, Y

    2009-01-01

    We obtain continuous wave mode-locked Nd:GdVO 4 -KTP laser with a SESAM. This is the first report of CW mode-locked Nd:GdVO 4 -KTP laser with a SESAM to our knowledge. 396 mw CW mode-locked pulse is achieved at the incident power of 7.653 W, with the repetition about 95 MHz. The pulse duration is assumed to be 5.5 ps, this is the shortest green pulse of 532 nm with SESAM

  5. A universal portable appliance for stellarator W7-X power supply controlling

    International Nuclear Information System (INIS)

    Xu Weihua

    2001-01-01

    In the project Wendelstein 7-X (W7-X), the popular field bus Profibus has been determined as a uniform connection between the central control system and all the subordinate systems. A universal embedded control system has been developed for W7-X power supply controlling. Siemens 80C167CR micro-controller is used as the central control unit of the system. With a user-defined printed circuit board (PCB) several control buses, i.e., Profibus, CAN, IEEE 488, RS485 and RS232 have been connected to the micro-controller. The corresponding hardware interfaces for the control buses have been designed. A graphic liquid crystal display (LCD) and a user-defined keyboard are used as user interface. The control software will be developed with a C-like language, i.e., C166 for the controller

  6. A 1.1nW Energy Harvesting System with 544pW Quiescent Power for Next Generation Implants.

    Science.gov (United States)

    Bandyopadhyay, Saurav; Mercier, Patrick P; Lysaght, Andrew C; Stankovic, Konstantina M; Chandrakasan, Anantha P

    2014-12-01

    This paper presents a nW power management unit (PMU) for an autonomous wireless sensor that sustains itself by harvesting energy from the endocochlear potential (EP), the 70-100 mV electrochemical bio-potential inside the mammalian ear. Due to the anatomical constraints inside the inner ear, the total extractable power from the EP is limited to 1.1-6.25 nW. A nW boost converter is used to increase the input voltage (30-55 mV) to a higher voltage (0.8 to 1.1 V) usable by CMOS circuits in the sensor. A pW Charge Pump circuit is used to minimize the leakage in the boost converter. Further, ultra-low-power control circuits consisting of digital implementations of input impedance adjustment circuits and Zero Current Switching circuits along with Timer and Reference circuits keep the quiescent power of the PMU down to 544 pW. The designed boost converter achieves a peak power conversion efficiency of 56%. The PMU can sustain itself and a duty-cyled ultra-low power load while extracting power from the EP of a live guinea pig. The PMU circuits have been implemented on a 0.18µm CMOS process.

  7. W-band power amplifier MMIC with 400 mW output power in 0.1 μm AlGaN/GaN technology

    NARCIS (Netherlands)

    Heijningen,M. van; Rodenburg, M.; Vliet, F.E. van; Massler, M.; Tessmann, A.; Brückner, F.; Müller, S.; Schwantuschke, D.; Quay; Narhi, T.

    2012-01-01

    The 0.1 μm AlGaN/GaN technology and design of two W-band power amplifiers in this technology are described. The dual-stage amplifier reaches an output power of 400 mW at 90 GHz at an operation bias of 20 V. Two designs with different driver to final stage gate width ratio are discussed. More than 10

  8. Improved photochemotherapy of malignant cells with daunomycin and the KTP laser.

    Science.gov (United States)

    Paiva, M B; Saxton, R E; Graeber, I P; Jongewaard, N; Eshraghi, A A; Suh, M J; Paek, W H; Castro, D J

    1998-01-01

    Laser photochemotherapy of malignancies may become an effective palliative treatment for advanced had and neck cancer using light-sensitive, chemotherapeutic drugs activated in tumors via interstitial laser fiberoptics. Previously, it was reported that cultured human P3 squamous cells incubated 2 hours with daunomycin (Dn) exhibited tenfold enhanced cytotoxicity after exposure to argon laser light at 514 nm. This short-term uptake leads to drug localization in cytoplasmic and membrane sites prior to nuclear accumulation and daunomycin topoisomerase inhibition. In the current study phototoxicity of Dn-sensitized human cancer cells was tested using broad-spectrum white light compared to monochromatic green-wavelength light. Drug uptake and laser energy levels were optimized for maximum synergy. To test light-enhanced chemotherapy in vitro, the kinetics of cell uptake and toxicity of daunomycin was measured at 1, 2, and 5 microg/ml in three human tumor cell lines: P3 squamous-cell carcinoma, M26 melanoma, and TE671 fibrosarcoma. After 2 hr Dn uptake, all cell lines were tested for phototherapy response by exposure to 300- to 900-nm visible light from a xenon lamp or monochromatic 532-nm green light from a KTP laser. When the KTP laser output was varied from 0 to 120 Joules in Dn-sensitized tumor cells, a linear phototherapy response was seen with energy as low as 12 J inducing drug phototoxicity. These results provide evidence that daunomycin cytotoxicity is enhanced when exposed to 532-nm laser illumination in the three tumor types tested and confirm that the response is related to both energy level and drug dose.

  9. Effects of 532 nm pulsed-KTP laser parameters on vessel ablation in the avian chorioallantoic membrane: implications for vocal fold mucosa.

    Science.gov (United States)

    Broadhurst, Matthew S; Akst, Lee M; Burns, James A; Kobler, James B; Heaton, James T; Anderson, R Rox; Zeitels, Steven M

    2007-02-01

    Selective vascular ablation (photoangiolysis) using pulsed lasers that target hemoglobin is an effective treatment strategy for many vocal fold lesions. However, vessel rupture with extravasation of blood reduces selectivity for vessels, which is frequently observed with the 0.45-ms, 585-nm pulsed dye laser. Previous studies have shown that vessel rupture is the result of vaporization of blood, an event that varies with laser pulse width and pulse fluence (energy per unit area). Clinical observations using a 532-nm wavelength pulsed potassium-titanyl-phosphate (KTP) laser revealed less laser-induced hemorrhage than the pulsed dye laser. This study investigated settings for the pulsed KTP laser to achieve selective vessel destruction without rupture using the avian chorioallantoic membrane under conditions similar to flexible laryngoscopic delivery of the laser in clinical practice. The chick chorioallantoic membrane offers convenient access to many small blood vessels similar in size to those targeted in human vocal fold. Using a 532-nm pulsed KTP laser, pulse width, pulse energy, and working distance from the optical delivery fiber were varied to assess influence on the ability to achieve vessel coagulation without vessel wall rupture. Third-order vessels (n = 135) were irradiated: Energy (471-550 mJ), pulse width (10, 15, 30 ms), and fiber-to-tissue distance (1 mm, 3 mm) were varied systematically. Selective vessel destruction without vessel wall rupture was more often achieved by increasing pulse width, increasing the fiber-to-tissue distance, and decreasing energy. Vessel destruction without rupture was consistently achieved using 15- or 30-ms pulses with a fiber-to-tissue distance of 3 mm (pulse fluence of 13-16 J/cm). This study substantiates our clinical observation that a 532-nm pulsed KTP laser was effective for ablating microcirculation while minimizing vessel wall rupture and hemorrhage.

  10. Loss of power output and laser fibre degradation during 120 watt lithium-triborate HPS laser vaporisation of the prostate

    Science.gov (United States)

    Hermanns, Thomas; Sulser, Tullio; Hefermehl, Lukas J.; Strebel, Daniel; Michel, Maurice-Stephan; Müntener, Michael; Meier, Alexander H.; Seifert, Hans-Helge

    2009-02-01

    It has recently been shown that laser fibre deterioration leads to a significant decrease of power output during 80 W potassium titanyl phosphate (KTP) laser vaporisation (LV) of the prostate. This decrease results in inefficient vaporisation especially towards the end of the procedure. For the new 120 W lithium-triborate (LBO) High Performance System (HPS) laser not only higher power but also changes in beam characteristics and improved fibre quality have been advertised. However, high laser power has been identified as a risk factor for laser fibre degradation. Between July and September 2008 25 laser fibres were investigated during routine 120 W LBO-LV in 20 consecutive patients. Laser beam power was measured at baseline and after the application of every 25 kJ during the LV procedure. Postoperatively, the surgeon subjectively rated the performance of the respective fibre on a scale from 1 to 4 (1 indicating perfect and 4 insufficient performance). Additionally, microscopic examination of the fibre tip was performed. Median energy applied was 212 kJ. Changes of power output were similar for all fibres. Typically, a steep decrease of power output within the first 50 kJ was followed by a continuous mild decrease until the end of the procedure. After the application of 50 kJ the median power output was 63% (58-73% interquartile range) of the baseline value. The median power output at the end of the 275 kJ-lifespan of the fibres was 42% (40-47%). The median surgeons' rating of the overall performance of the laser fibres was 2 and the median estimated final decrease of power output 60%. Some degree of degradation at the emission window was microscopically detectable in all cases after the procedure. However, even after the application of 275 kJ, these structural changes were only moderate. Minor degradation of the laser fibre was associated with a significant decrease of power output during 120 W LBO-LV. However, following an early, steep decrease, power output

  11. Funciones termodinámicas relativas a la transferencia del ketoprófen desde el agua hasta algunos sistemas orgánicos Thermodynamic functions relative to the transfer of ketoprofen from water to some organic systems

    Directory of Open Access Journals (Sweden)

    Hernán R. Lozano

    2006-07-01

    Full Text Available The thermodynamics of molal partitioning of ketoprofen (KTP was studied in cyclohexane/buffer (CH/W, octanol/buffer (ROH/W, and dimyristoyl phosphatidylcholine (DMPC, dipalmitoyl phosphatidylcholine (DPPC, and egg lecithin (EGG/W liposome systems. In all cases the partition coefficients (Kmo/wwere greater than unity; therefore the standard free energies of transfer were negative indicating affinity of KTP for organic media. The Kmo/w values were approximately seventy-fold higher in the ROH/W system compared with the CH/W system. On the other hand, the Kmo/w values were approximately ten or fifty-fold higher in the liposomes compared with the ROH/W system. In all cases, the standard enthalpies and entropies of transfer of KTP were positive indicating some degree of participation of the hydrophobic hydration on partitioning processes.

  12. 3 kW Stirling engine for power and heat production

    DEFF Research Database (Denmark)

    Thorsen, Jan Eric; Bovin, Jonas Kabell; Carlsen, Henrik

    1996-01-01

    A new 3 kW Beta-type Stirling engine has been developed. The engine uses natural gas as fuel and is designed for use as a small combined heat and power plant for single family houses. The electrical power is supplied to the grid. The engine is made as a hermetic device, where the crank mechanism...... and the alternator are built into a pressurized crank casing. The engine produces 3 kW of shaft power corresponding to 2.4 kW of electric power. The heat input is 10 kW representing a shaft efficiency of 30% and an electric efficiency of 24%. Helium at 8 MPa mean pressure is used as the working gas. The crank...... for X-heads. A grease-lubricated needle and ball bearings are used in the kinematic crank mechanism. The burner includes an air preheater and a water jacket which makes it possible to utilize nearly all of the heat from the combustion gases. The performance of the engine has been tested as a function...

  13. A Compact Two-Stage 120 W GaN High Power Amplifier for SweepSAR Radar Systems

    Science.gov (United States)

    Thrivikraman, Tushar; Horst, Stephen; Price, Douglas; Hoffman, James; Veilleux, Louise

    2014-01-01

    This work presents the design and measured results of a fully integrated switched power two-stage GaN HEMT high-power amplifier (HPA) achieving 60% power-added efficiency at over 120Woutput power. This high-efficiency GaN HEMT HPA is an enabling technology for L-band SweepSAR interferometric instruments that enable frequent repeat intervals and high-resolution imagery. The L-band HPA was designed using space-qualified state-of-the-art GaN HEMT technology. The amplifier exhibits over 34 dB of power gain at 51 dBm of output power across an 80 MHz bandwidth. The HPA is divided into two stages, an 8 W driver stage and 120 W output stage. The amplifier is designed for pulsed operation, with a high-speed DC drain switch operating at the pulsed-repetition interval and settles within 200 ns. In addition to the electrical design, a thermally optimized package was designed, that allows for direct thermal radiation to maintain low-junction temperatures for the GaN parts maximizing long-term reliability. Lastly, real radar waveforms are characterized and analysis of amplitude and phase stability over temperature demonstrate ultra-stable operation over temperature using integrated bias compensation circuitry allowing less than 0.2 dB amplitude variation and 2 deg phase variation over a 70 C range.

  14. Advanced 35 W Free-Piston Stirling Engine for Space Power Applications

    Science.gov (United States)

    Wood, J. Gary; Lane, Neill

    2003-01-01

    This paper presents the projected performance and overall design characteristics of a high efficiency, low mass 35 W free-piston Stirling engine design. Overall (engine plus linear alternator) thermodynamic performance greater than 50% of Carnot, with a specific power close to 100 W/kg appears to be a reasonable goal at this small power level. Supporting test data and analysis results from exiting engines are presented. Design implications of high specific power in relatively low power engines is presented and discussed.

  15. Efficient and high-power green beam generation by frequency ...

    Indian Academy of Sciences (India)

    Rz; 42.60.Gd. 1. Introduction. High-average-power green lasers are required for various applications in industry, ... mode size, however, vary dynamically with the pump power due to thermal lensing in the Nd:YAG rod. ... fundamental mode size at the Nd:YAG rod as well as at the KTP crystal is plotted as a function of the ...

  16. All-periodically poled, high-power, continuous-wave, single-frequency tunable UV source.

    Science.gov (United States)

    Aadhi, A; Chaitanya N, Apurv; Jabir, M V; Singh, R P; Samanta, G K

    2015-01-01

    We report on experimental demonstration of an all-periodically poled, continuous-wave (CW), high-power, single-frequency, ultra-violet (UV) source. Based on internal second-harmonic-generation (SHG) of a CW singly resonant optical parametric oscillator (OPO) pumped in the green, the UV source provides tunable radiation across 398.94-417.08 nm. The compact source comprising of a 25-mm-long MgO-doped periodically poled stoichiometric lithium tantalate (MgO:sPPLT) crystal of period Λ(SLT)=8.5  μm for OPO and a 5-mm-long, multi-grating (Λ(KTP)=3.3, 3.4, 3.6 and 3.8 μm), periodically poled potassium titanium phosphate (PPKTP) for intra-cavity SHG, provides as much as 336 mW of UV power at 398.94 nm, corresponding to a green-to-UV conversion efficiency of ∼6.7%. In addition, the singly resonant OPO (SRO) provides 840 mW of idler at 1541.61 nm and substantial signal power of 108 mW at 812.33 nm transmitted through the high reflective cavity mirrors. UV source provides single-frequency radiation with instantaneous line-width of ∼18.3  MHz and power >100  mW in Gaussian beam profile (ellipticity >92%) across the entire tuning range. Access to lower UV wavelengths requires smaller grating periods to compensate high phase-mismatch resulting from high material dispersion in the UV wavelength range. Additionally, we have measured the normalized temperature and spectral acceptance bandwidth of PPKTP crystal in the UV wavelength range to be ∼2.25°C·cm and ∼0.15  nm·cm, respectively.

  17. Comparison of Critical Power and W' Derived From 2 or 3 Maximal Tests.

    Science.gov (United States)

    Simpson, Len Parker; Kordi, Mehdi

    2017-07-01

    Typically, accessing the asymptote (critical power; CP) and curvature constant (W') parameters of the hyperbolic power-duration relationship requires multiple constant-power exhaustive-exercise trials spread over several visits. However, more recently single-visit protocols and personal power meters have been used. This study investigated the practicality of using a 2-trial, single-visit protocol in providing reliable CP and W' estimates. Eight trained cyclists underwent 3- and 12-min maximal-exercise trials in a single session to derive (2-trial) CP and W' estimates. On a separate occasion a 5-min trial was performed, providing a 3rd trial to calculate (3-trial) CP and W'. There were no differences in CP (283 ± 66 vs 282 ± 65 W) or W' (18.72 ± 6.21 vs 18.27 ± 6.29 kJ) obtained from either the 2-trial or 3-trial method, respectively. After 2 familiarization sessions (completing a 3- and a 12-min trial on both occasions), both CP and W' remained reliable over additional separate measurements. The current study demonstrates that after 2 familiarization sessions, reliable CP and W' parameters can be obtained from trained cyclists using only 2 maximal-exercise trials. These results offer practitioners a practical, time-efficient solution for incorporating power-duration testing into applied athlete support.

  18. Gigawatt peak power generation in a relativistic klystron amplifier driven by 1 kW seed-power

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Y. [Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900 (China); Science and Technology on High Power Microwave Laboratory, Mianyang 621900 (China); Xie, H. Q. [College of Science, Southwestern University of Science and Technology, Mianyang 621010 (China); Li, Z. H.; Zhang, Y. J.; Ma, Q. S. [Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900 (China)

    2013-11-15

    An S-band high gain relativistic klystron amplifier driven by kW-level RF power is proposed and studied experimentally. In the device, the RF lossy material is introduced to suppress higher mode excitation. An output power of 1.95 GW with a gain of 62.8 dB is obtained in the simulation. Under conditions of an input RF power of 1.38 kW, a microwave pulse with power of 1.9 GW, frequency of 2.86 GHz, and duration of 105 ns is generated in the experiment, and the corresponding gain is 61.4 dB.

  19. Gigawatt peak power generation in a relativistic klystron amplifier driven by 1 kW seed-power

    Science.gov (United States)

    Wu, Y.; Xie, H. Q.; Li, Z. H.; Zhang, Y. J.; Ma, Q. S.

    2013-11-01

    An S-band high gain relativistic klystron amplifier driven by kW-level RF power is proposed and studied experimentally. In the device, the RF lossy material is introduced to suppress higher mode excitation. An output power of 1.95 GW with a gain of 62.8 dB is obtained in the simulation. Under conditions of an input RF power of 1.38 kW, a microwave pulse with power of 1.9 GW, frequency of 2.86 GHz, and duration of 105 ns is generated in the experiment, and the corresponding gain is 61.4 dB.

  20. Design And Construction Of 300W Audio Power Amplifier For Classroom

    Directory of Open Access Journals (Sweden)

    Shune Lei Aung

    2015-07-01

    Full Text Available Abstract This paper describes the design and construction of 300W audio power amplifier for classroom. In the construction of this amplifier microphone preamplifier tone preamplifier equalizer line amplifier output power amplifier and sound level indicator are included. The output power amplifier is designed as O.C.L system and constructed by using Class B among many types of amplifier classes. There are two types in O.C.L system quasi system and complementary system. Between them the complementary system is used in the construction of 300W audio power amplifier. The Multisim software is utilized for the construction of audio power amplifier.

  1. Free-Space Quantum Key Distribution with a High Generation Rate KTP Waveguide Photon-Pair Source

    Science.gov (United States)

    Wilson, J.; Chaffee, D.; Wilson, N.; Lekki, J.; Tokars, R.; Pouch, J.; Lind, A.; Cavin, J.; Helmick, S.; Roberts, T.; hide

    2016-01-01

    NASA awarded Small Business Innovative Research (SBIR) contracts to AdvR, Inc to develop a high generation rate source of entangled photons that could be used to explore quantum key distribution (QKD) protocols. The final product, a photon pair source using a dual-element periodically- poled potassium titanyl phosphate (KTP) waveguide, was delivered to NASA Glenn Research Center in June of 2015. This paper describes the source, its characterization, and its performance in a B92 (Bennett, 1992) protocol QKD experiment.

  2. Power-Combined GaN Amplifier with 2.28-W Output Power at 87 GHz

    Science.gov (United States)

    Fung, King Man; Ward, John; Chattopadhyay, Goutam; Lin, Robert H.; Samoska, Lorene A.; Kangaslahti, Pekka P.; Mehdi, Imran; Lambrigtsen, Bjorn H.; Goldsmith, Paul F.; Soria, Mary M.; hide

    2011-01-01

    Future remote sensing instruments will require focal plane spectrometer arrays with higher resolution at high frequencies. One of the major components of spectrometers are the local oscillator (LO) signal sources that are used to drive mixers to down-convert received radio-frequency (RF) signals to intermediate frequencies (IFs) for analysis. By advancing LO technology through increasing output power and efficiency, and reducing component size, these advances will improve performance and simplify architecture of spectrometer array systems. W-band power amplifiers (PAs) are an essential element of current frequency-multiplied submillimeter-wave LO signal sources. This work utilizes GaN monolithic millimeter-wave integrated circuit (MMIC) PAs developed from a new HRL Laboratories LLC 0.15- m gate length GaN semiconductor transistor. By additionally waveguide power combining PA MMIC modules, the researchers here target the highest output power performance and efficiency in the smallest volume achievable for W-band.

  3. 1000kW on-site PAFC power plant development and demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Satomi, Tomohide; Koike, Shunichi [Phosphoric Acid Fuel Cell Technology Research Association (PAFC-TRA), Osaka (Japan); Ishikawa, Ryou [New Energy and Industrial Technology Development Organization (NEDO), Tokyo (Japan)

    1996-12-31

    Phosphoric Acid Fuel Cell Technology Research Association (PAFC-TRA) and New Energy and Industrial Technology Development Organization (NEDO) have been conducting a joint project on development of a 5000kW urban energy center type PAFC power plant (pressurized) and a 1000kW on-site PAFC power plant (non-pressurized). The objective of the technical development of 1000kW on-site PAFC power plant is to realize a medium size power plant with an overall efficiency of over 70% and an electrical efficiency of over 36%, that could be installed in a large building as a cogeneration system. The components and system integration development work and the plant design were performed in 1991 and 1992. Manufacturing of the plant and installation at the test site were completed in 1994. PAC test was carried out in 1994, and generation test was started in January 1995. Demonstration test is scheduled for 1995 and 1996.

  4. A 25-kW Series-Resonant Power Converter

    Science.gov (United States)

    Frye, R. J.; Robson, R. R.

    1986-01-01

    Prototype exhibited efficiency of 93.9 percent. 25-kW resonant dc/dc power converter designed, developed, fabricated, and tested, using Westinghouse D7ST transistors as high-power switches. D7ST transistor characterized for use as switch in series-resonant converters, and refined base-drive circuit developed. Technical base includes advanced switching magnetic, and filter components, mathematical circuit models, control philosophies, and switch-drive strategies. Power-system benefits such as lower losses when used for high-voltage distribution, and reduced magnetics and filter mass realized.

  5. A 50-kW Module Power Station of Directly Solar-Pumped Iodine Laser

    Science.gov (United States)

    Choi, S. H.; Lee, J. H.; Meador, W. E.; Conway, E. J.

    1997-01-01

    The conceptual design of a 50 kW Directly Solar-Pumped Iodine Laser (DSPIL) module was developed for a space-based power station which transmits its coherent-beam power to users such as the moon, Martian rovers, or other satellites with large (greater than 25 kW) electric power requirements. Integration of multiple modules would provide an amount of power that exceeds the power of a single module by combining and directing the coherent beams to the user's receiver. The model developed for the DSPIL system conservatively predicts the laser output power (50 kW) that appears much less than the laser output (93 kW) obtained from the gain volume ratio extrapolation of experimental data. The difference in laser outputs may be attributed to reflector configurations adopted in both design and experiment. Even though the photon absorption by multiple reflections in experimental cavity setup was more efficient, the maximum secondary absorption amounts to be only 24.7 percent of the primary. However, the gain volume ratio shows 86 percent more power output than theoretical estimation that is roughly 60 percent more than the contribution by the secondary absorption. Such a difference indicates that the theoretical model adopted in the study underestimates the overall performance of the DSPIL. This fact may tolerate more flexible and radical selection of design parameters than used in this design study. The design achieves an overall specific power of approximately 5 W/kg and total mass of 10 metric tons.

  6. Biopsy of Different Oral Soft Tissues Lesions by KTP and Diode Laser: Histological Evaluation

    Directory of Open Access Journals (Sweden)

    Umberto Romeo

    2014-01-01

    Full Text Available Introduction. Oral biopsy aims to obtain clear and safe diagnosis; it can be performed by scalpel or laser. The controversy in this latter application is the thermal alteration due to tissue heating. The aim of this study is the histological evaluation of margins of “in vivo” biopsies collected by diode and KTP lasers. Material and Methods. 17 oral benign lesions biopsies were made by diode 808 nm (SOL, DenMatItalia, Italy and KTP 532 nm (SmartLite, DEKA, Italy. Samples were observed at OM LEICA DM 2000; margin alterations were evaluated through Leica Application Suite 3.4. Results. Epithelial and connective damages were assessed for each pathology with an average of 0.245 mm and a standard deviation of ±0.162 mm in mucoceles, 0.382 mm ± 0.149 mm in fibromas, 0.336 mm ± 0.106 mm in hyperkeratosis, 0.473 mm ± 0.105 mm in squamous hyperplasia, 0.182 mm in giant cell granuloma, and 0.149 mm in melanotic macula. Discussion. The histologic aspect of lesions influenced the response to laser, whereas the greater inflammation and cellularity were linked with the higher thermal signs. Many artifacts were also associated to histologic procedures. Conclusion. Both tested lasers permitted sure histologic diagnosis. However, it is suggested to enlarge biopsies of about 0.5 mm, to avoid thermal alterations, especially in inflammatory lesions like oral lichen planus.

  7. Shear Bond Strength of Composite and Ceromer Superstructures to Direct Laser Sintered and Ni-Cr-Based Infrastructures Treated with KTP, Nd:YAG, and Er:YAG Lasers: An Experimental Study.

    Science.gov (United States)

    Gorler, Oguzhan; Hubbezoglu, Ihsan; Ulgey, Melih; Zan, Recai; Guner, Kubra

    2018-04-01

    The aim of this study was to examine the shear bond strength (SBS) of ceromer and nanohybrid composite to direct laser sintered (DLS) Cr-Co and Ni-Cr-based metal infrastructures treated with erbium-doped yttrium aluminum garnet (Er:YAG), neodymium-doped yttrium aluminum garnet (Nd:YAG), and potassium titanyl phosphate (KTP) laser modalities in in vitro settings. Experimental specimens had four sets (n = 32) including two DLS infrastructures with ceromer and nanohybrid composite superstructures and two Ni-Cr-based infrastructures with ceromer and nanohybrid composite superstructures. Of each infrastructure set, the specimens randomized into four treatment modalities (n = 8): no treatment (controls) and Er:YAG, Nd:YAG, and KTP lasers. The infrastructures were prepared in the final dimensions of 7 × 3 mm. Ceromer and nanohybrid composite was applied to the infrastructures after their surface treatments according to randomization. The SBS of specimens was measured to test the efficacy of surface treatments. Representative scanning electron microscopy (SEM) images after laser treatments were obtained. Overall, in current experimental settings, Nd:YAG, KTP, and Er:YAG lasers, in order of efficacy, are effective to improve the bonding of ceromer and nanohybrid composite to the DLS and Ni-Cr-based infrastructures (p laser is more effective in the DLS/ceromer infrastructures (p laser, as second more effective preparation, is more effective in the DLS/ceromer infrastructures (p laser modalities, in order of success, Nd:YAG, KTP, and Er:YAG, are effective to increase bonding of these structures.

  8. Design and implementation of a 38 kW dish-Stirling concentrated solar power system

    Science.gov (United States)

    Yan, J.; Peng, Y. D.; Cheng, Z. R.; Liu, F. M.; Tang, X. H.

    2017-11-01

    Dish-Stirling concentrated solar power system (DS-CSP) is an important pathway for converting solar energy into electricity at high efficiency. In this study, a rated power 38 kW DS-CSP system was developed (installed in Xiangtan Electric Manufacturing Group). The heat engine adopted the alpha-type four cylinders double-acting Stirling engine (Stirling Biopower Flexgen S260). The absorber flux distribution simulation was conducted using ray tracing method and then the 204 m2 parabolic dish concentrator system (diameter is 17.70 m and focal length is 9.49 m) with single concentrator plus single pillar supporting has been designed and built. A water-cooled disc target and an absorber imitation device were adopted to test the tracking performance of the dish concentrator system, homogeneity of the focal spot and flux distribution of the absorber. Finally, the S260 Stirling engine was installed on the focal position of the dish concentrator and then the net output power date of the 38 kW DS-CSP system was tested. The absorber overheating problem on the DS-CSP system performance was discussed when the DS-CSP system was installed in different locations. The testing result shows that this system achieved the net output power of 38 kW and solar-to-electricity efficiency (SEE) of 25.3% with the direct normal irradiation (DNI) at 750 W/m2. The net output power can further increase to 40.5 kW with the SEE of 26.6% when the DNI reaches up to the maximum of 761 W/m2. The net output power of the 38 kW DS-CSP system has a linear function relationship with the DNI. The fitting function is Net power output=0.1003×DNI-36.129, where DNI is at the range of 460∼761 W/m2. This function could be used to predict the amount of the 38 kW DS-CSP system annual generation power.

  9. A 100 kW-Class Technology Demonstrator for Space Solar Power

    Science.gov (United States)

    Carrington, Connie; Howell, Joe; Day, Greg

    2004-01-01

    A first step in the development of solar power from space is the flight demonstration of critical technologies. These fundamental technologies include efficient solar power collection and generation, power management and distribution, and thermal management. In addition, the integration and utilization of these technologies into a viable satellite bus could provide an energy-rich platform for a portfolio of payload experiments such as wireless power transmission (WPT). This paper presents the preliminary design of a concept for a 100 kW-class fiee-flying platform suitable for flight demonstration of technology experiments. Recent space solar power (SSP) studies by NASA have taken a stepping stones approach that lead to the gigawatt systems necessary to cost-effectively deliver power from space. These steps start with a 100 kW-class satellite, leading to a 500 kW and then a 1 MW-class platform. Later steps develop a 100 M W bus that could eventually lead to a 1-2 GW pilot plant for SSP. Our studies have shown that a modular approach is cost effective. Modular designs include individual laser-power-beaming satellites that fly in constellations or that are autonomously assembled into larger structures at geosynchronous orbit (GEO). Microwave power-beamed approaches are also modularized into large numbers of identical units of solar arrays, power converters, or supporting structures for arrays and microwave transmitting antennas. A cost-effective approach to launching these modular units is to use existing Earth-to-orbit (ETO) launch systems, in which the modules are dropped into low Earth orbit (LEO) and then the modules perform their own orbit transfer to GEO using expendable solar arrays to power solar electric thrusters. At GEO, the modules either rendezvous and are assembled robotically into larger platforms, or are deployed into constellations of identical laser power-beaming satellites. Since solar electric propulsion by the modules is cost-effective for both

  10. 532 nm KTP激光治疗鲜红斑痣的自身对照研究%Efficacy and safety of 532 nm KTP laser in the treatment of port-wine stains

    Institute of Scientific and Technical Information of China (English)

    杨千里; 郑文渊; 卢忠

    2017-01-01

    Objective: To compare the efficacy and adverse reactions of 532 nm KTP laser and 595 nm pulsed dye laser in the treatment of port wine stain. Methods:The lesions of 18 patients were divided into two areas. One area was treated with 532 nm KTP laser and another area was treated with 595 nm pulsed dye la ̄ser, once every 2~3 months for 2~4 times. The safety and efficacy were evaluated after the treatment and in 2-3 months after the treatment. Results:There was no significant difference in the cure rate between 532 nm KTP laser and 595 nm pulsed dye laser. Some patients who were resistant to pulsed dye laser treatment were also sensitive to the treatment with 532 nm KTP laser. There were less pain and less purpura in the group of 532 nm KTP laser. Only one patient in each group developed hyperpigmentation. Conclusion: 532 nm KTP laser has similar efficacy to 595 nm pulsed dye laser and relatively less adverse reactions. It can be used as an alternative treatment of port wine stain.%目的::比较532 nm KTP激光与脉冲染料激光( PDL)对鲜红斑痣的疗效及安全性。方法:将18例鲜红斑痣患者的自身皮损随机分成KTP激光治疗区及PDL治疗区,分别予以532 nm KTP激光及595 nm PDL治疗,每2~3个月治疗一次,共2~4次。每次治疗前、后即刻及治疗后2~3个月对患者激光治疗后的皮损进行疗效及安全性评价。结果:532 nm KTP激光治疗组及595 nm PDL治疗组治疗后疗效均无显著差异。在一些既往曾接受PDL治疗疗效不佳的患者,经532 nm KTP 激光治疗后,皮损取得一定改善。532 nm KTP激光治疗组在治疗时疼痛程度及治疗后紫癜程度均显著低于595 nmPDL治疗组。两组均有1例色素沉着发生。结论:532 nm KTP激光治疗鲜红斑痣的疗效较好,不良反应少,安全性好,可以作为鲜红斑痣治疗的另一方案。

  11. Development of a 200kW multi-fuel type PAFC power plant

    Energy Technology Data Exchange (ETDEWEB)

    Take, Tetsuo; Kuwata, Yutaka; Adachi, Masahito; Ogata, Tsutomu [NTT Integrated Information & Energy System Labs., Tokyo (Japan)

    1996-12-31

    Nippon Telegraph and Telephone Corporation (NFT) has been developing a 200 kW multi-fuel type PAFC power plant which can generate AC 200 kW of constant power by switching fuel from pipeline town gas to liquefied propane gas (LPG) and vice versa. This paper describes the outline of the demonstration test plant and test results of its fundamental characteristics.

  12. Generation of continuously tunable, 5-12 {mu}m radiation by difference frequency mixing of output waves of a KTP optical parametric oscillator in a ZnGeP{sub 2} crystal

    Energy Technology Data Exchange (ETDEWEB)

    Haidar, S [Research Institute of Electrical Communication (RIEC), Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai-shi 980-8577 (Japan); Miyamoto, K [Research Institute of Electrical Communication (RIEC), Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai-shi 980-8577 (Japan); Ito, H [Research Institute of Electrical Communication (RIEC), Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai-shi 980-8577 (Japan)

    2004-12-07

    Signal and idlers waves obtained from a Nd : YAG laser pumped KTP optical parametric oscillator (OPO) are difference frequency mixed in a ZnGeP{sub 2} (ZGP) crystal to generate radiation in the mid-infrared. The KTP OPO is operated in the type-II phase matching mode, and the extraordinary and ordinary waves are tunable from 1.76 {mu}m to 2.36 {mu}m and from 2.61 {mu}m to 1.90 {mu}m, respectively. The orthogonally polarized waves are difference frequency mixed in a ZGP crystal to generate mid-IR radiation tunable from 5 to 12 {mu}m.

  13. Green-diode-pumped femtosecond Ti:Sapphire laser with up to 450 mW average power.

    Science.gov (United States)

    Gürel, K; Wittwer, V J; Hoffmann, M; Saraceno, C J; Hakobyan, S; Resan, B; Rohrbacher, A; Weingarten, K; Schilt, S; Südmeyer, T

    2015-11-16

    We investigate power-scaling of green-diode-pumped Ti:Sapphire lasers in continuous-wave (CW) and mode-locked operation. In a first configuration with a total pump power of up to 2 W incident onto the crystal, we achieved a CW power of up to 440 mW and self-starting mode-locking with up to 200 mW average power in 68-fs pulses using semiconductor saturable absorber mirror (SESAM) as saturable absorber. In a second configuration with up to 3 W of pump power incident onto the crystal, we achieved up to 650 mW in CW operation and up to 450 mW in 58-fs pulses using Kerr-lens mode-locking (KLM). The shortest pulse duration was 39 fs, which was achieved at 350 mW average power using KLM. The mode-locked laser generates a pulse train at repetition rates around 400 MHz. No complex cooling system is required: neither the SESAM nor the Ti:Sapphire crystal is actively cooled, only air cooling is applied to the pump diodes using a small fan. Because of mass production for laser displays, we expect that prices for green laser diodes will become very favorable in the near future, opening the door for low-cost Ti:Sapphire lasers. This will be highly attractive for potential mass applications such as biomedical imaging and sensing.

  14. Vectronic's Power Macintosh G3 (B & W)

    CERN Multimedia

    1999-01-01

    Apple introduced the Power Macintosh G3 Blue and White (B & W) on January 5, 1999. The Power Macintosh G3 line stayed in production until August 1999, and was replaced by the Power Macintosh G4, which used the same chassis. The Power Macintosh G3 originally cost between $1599 and $2900 depending on options. The three original Power Macintosh G3 models shipped with a 300 MHz, 350 MHz, or 400 MHz PowerPC 750 (G3) processor. Just pull on the small round handle on the side of the tower, and the entire side of the computer opens up. The G3's motherboard is mounted on that surface, giving you easy access for upgrading RAM or installed PCI cards. Apple added new ports (USB and the much-anticipated FireWire) that took the place of historic, and quickly becoming antiquated, Mac serial (printer and modem) ports. The Power Macintosh G3 has two USB (12 Mbps) ports, two FireWire (400 Mbps) ports, one 10/100BaseT Ethernet port, an RJ-11 jack for an optional 56K modem, a sound out and sound in jack, and one ADB (Apple D...

  15. Thermal oxidation of reactively sputtered amorphous W80N20 films

    International Nuclear Information System (INIS)

    Vu, Q.T.; Pokela, P.J.; Garden, C.L.; Kolawa, E.; Raud, S.; Nicolet, M.

    1990-01-01

    The oxidation behavior of reactively sputtered amorphous tungsten nitride of composition W 80 N 20 was investigated in dry and wet oxidizing ambient in the temperature range of 450 degree C--575 degree C. A single WO 3 oxide phase is observed. The growth of the oxide follows a parabolic time dependence which is attributed to a process controlled by the diffusivity of the oxidant in the oxide. The oxidation process is thermally activated with an activation energy of 2.5±0.05 eV for dry ambient and 2.35±0.05 eV for wet ambient. The pre-exponential factor of the reaction constant for dry ambient is 1.1x10 21 A 2 /min; that for wet ambient is only about 10 times less and is equal to 1.3x10 20 A 2 /min

  16. Pratt & Whitney Advanced Ducted Propulsor (ADP) Engine Test in 40x80ft w.t.: Engineers Peter

    Science.gov (United States)

    1993-01-01

    Pratt & Whitney Advanced Ducted Propulsor (ADP) Engine Test in 40x80ft w.t.: Engineers Peter Zell (left) and Dr Clifton Horne (right) are shown preparing a laser light sheet for a flow visualization test. Shown standing in the nacelle of the ADP is John Girvin, senior test engineer for Pratt & Whitney.

  17. Development of 20 kW input power coupler for 1.3 GHz ERL main linac. Component test at 30 kW IOT test stand

    International Nuclear Information System (INIS)

    Sakai, Hiroshi; Umemori, Kensei; Sakanaka, Shogo; Takahashi, Takeshi; Furuya, Takaaki; Shinoe, Kenji; Ishii, Atsushi; Nakamura, Norio; Sawamura, Masaru

    2009-01-01

    We started to develop an input coupler for a 1.3 GHz ERL superconducting cavity. Required input power is about 20 kW for the cavity acceleration field of 20 MV/m and the beam current of 100 mA in energy recovery operation. The input coupler is designed based on the STF-BL input coupler and some modifications are applied to the design for the CW 20 kW power operation. We fabricated input coupler components such as ceramic windows and bellows and carried out the high-power test of the components by using a 30 kW IOT power source and a test stand constructed for the highpower test. In this report, we mainly describe the results of the high-power test of ceramic window and bellows. (author)

  18. Measurements of the mass of the W boson in the W+W- → qq-barqq-bar channel with the ALEPH detector

    International Nuclear Information System (INIS)

    Chalmers, M.D.K.

    1999-12-01

    A measurement of the mass of the W boson from e + e - → W + W - → qq-barqq-bar events is presented, from LEP data collected at √s = 189 GeV during 1998 with the ALEPH detector. The procedure of direct reconstruction of the W + W - final state invariant mass distribution is adopted, with an optimisation of the event selection and jet clustering algorithms. A two dimensional Monte Carlo reweighting technique is used to extract the W mass and a full discussion of the systematic uncertainties is given. The W mass is measured to be: M W = 80.556 ± 0.110(stat.) ± 0.039(syst.) ± 0.056(F.S.I.) ± 0.017(LEP) GeV/c 2 . A new technique for extracting the W mass using a two dimensional Kolmogorov Smirnov test is introduced. The W mass using this method is measured to be: M W KS = 80.423 ± 0.160(expected stat.) GeV/c 2 , which is compared with that from the method of maximum likelihood. Rigorous optimisation and stability checks on the W mass estimator and its error are presented, and the result put into the context of a LEP and subsequently world average value: M W world = 80.394 ± 0.042 GeV/c 2 . The implications of this result are interpreted by comparing it with the indirect W mass measurement from the Standard Model prediction: M W indirect = 80.381 ± 0.026 GeV/c 2 . A discussion and outlook for the W mass measurement at LEP is given. (author)

  19. W-band Solid State Power Amplifier for Remote Sensing Radars, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — High power, compact, reliable and affordable power amplifiers operating in the W-band (94 GHz region) are critical to realizing transmitters for many NASA missions...

  20. W-Band Solid State Power Amplifier for Remote Sensing Radars, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — High power, compact, reliable and affordable power amplifiers operating in the W-band (94 GHz region) are critical to realizing transmitters for many NASA missions...

  1. A novel power source for high-precision, highly efficient micro w-EDM

    International Nuclear Information System (INIS)

    Chen, Shun-Tong; Chen, Chi-Hung

    2015-01-01

    The study presents the development of a novel power source for high-precision, highly efficient machining of micropart microstructures using micro wire electrical discharge machining (w-EDM). A novel power source based on a pluri resistance–capacitance (pRC) circuit that can generate a high-frequency, high-peak current with a short pulse train is proposed and designed to enhance the performance of micro w-EDM processes. Switching between transistors is precisely controlled in the designed power source to create a high-frequency short-pulse train current. Various microslot cutting tests in both aluminum and copper alloys are conducted. Experimental results demonstrate that the pRC power source creates instant spark erosion resulting in markedly less material for removal, diminishing discharge crater size, and consequently an improved surface finish. A new evaluation approach for spark erosion ability (SEA) to assess the merits of micro EDM power sources is also proposed. In addition to increasing the speed of micro w-EDM by increasing wire feed rates by 1.6 times the original feed rate, the power source is more appropriate for machining micropart microstructures since there is less thermal breaking. Satisfactory cutting of an elaborate miniature hook-shaped structure and a high-aspect ratio microstructure with a squared-pillar array also reveal that the developed pRC power source is effective, and should be very useful in the manufacture of intricate microparts. (paper)

  2. Development of high average power industrial Nd:YAG laser with peak power of 10 kW class

    International Nuclear Information System (INIS)

    Kim, Cheol Jung; Kim, Jeong Mook; Jung, Chin Mann; Kim, Soo Sung; Kim, Kwang Suk; Kim, Min Suk; Cho, Jae Wan; Kim, Duk Hyun

    1992-03-01

    We developed and commercialized an industrial pulsed Nd:YAG laser with peak power of 10 kW class for fine cutting and drilling applications. Several commercial models have been investigated in design and performance. We improved its quality to the level of commercial Nd:YAG laser by an endurance test for each parts of laser system. The maximum peak power and average power of our laser were 10 kW and 250 W, respectively. Moreover, the laser pulse width could be controlled from 0.5 msec to 20 msec continuously. Many optical parts were localized and lowered much in cost. Only few parts were imported and almost 90% in cost were localized. Also, to accellerate the commercialization by the joint company, the training and transfer of technology were pursued in the joint participation in design and assembly by company researchers from the early stage. Three Nd:YAG lasers have been assembled and will be tested in industrial manufacturing process to prove the capability of developed Nd:YAG laser with potential users. (Author)

  3. A miniaturized mW thermoelectric generator for nw objectives: continuous, autonomous, reliable power for decades.

    Energy Technology Data Exchange (ETDEWEB)

    Aselage, Terrence Lee; Siegal, Michael P.; Whalen, Scott; Frederick, Scott K.; Apblett, Christopher Alan; Moorman, Matthew Wallace

    2006-10-01

    We have built and tested a miniaturized, thermoelectric power source that can provide in excess of 450 {micro}W of power in a system size of 4.3cc, for a power density of 107 {micro}W/cc, which is denser than any system of this size previously reported. The system operates on 150mW of thermal input, which for this system was simulated with a resistive heater, but in application would be provided by a 0.4g source of {sup 238}Pu located at the center of the device. Output power from this device, while optimized for efficiency, was not optimized for form of the power output, and so the maximum power was delivered at only 41mV. An upconverter to 2.7V was developed concurrently with the power source to bring the voltage up to a usable level for microelectronics.

  4. A 6.45 μW Self-Powered SoC With Integrated Energy-Harvesting Power Management and ULP Asymmetric Radios for Portable Biomedical Systems.

    Science.gov (United States)

    Roy, Abhishek; Klinefelter, Alicia; Yahya, Farah B; Chen, Xing; Gonzalez-Guerrero, Luisa Patricia; Lukas, Christopher J; Kamakshi, Divya Akella; Boley, James; Craig, Kyle; Faisal, Muhammad; Oh, Seunghyun; Roberts, Nathan E; Shakhsheer, Yousef; Shrivastava, Aatmesh; Vasudevan, Dilip P; Wentzloff, David D; Calhoun, Benton H

    2015-12-01

    This paper presents a batteryless system-on-chip (SoC) that operates off energy harvested from indoor solar cells and/or thermoelectric generators (TEGs) on the body. Fabricated in a commercial 0.13 μW process, this SoC sensing platform consists of an integrated energy harvesting and power management unit (EH-PMU) with maximum power point tracking, multiple sensing modalities, programmable core and a low power microcontroller with several hardware accelerators to enable energy-efficient digital signal processing, ultra-low-power (ULP) asymmetric radios for wireless transmission, and a 100 nW wake-up radio. The EH-PMU achieves a peak end-to-end efficiency of 75% delivering power to a 100 μA load. In an example motion detection application, the SoC reads data from an accelerometer through SPI, processes it, and sends it over the radio. The SPI and digital processing consume only 2.27 μW, while the integrated radio consumes 4.18 μW when transmitting at 187.5 kbps for a total of 6.45 μW.

  5. Double-pass tapered amplifier diode laser with an output power of 1 W for an injection power of only 200 μW.

    Science.gov (United States)

    Bolpasi, V; von Klitzing, W

    2010-11-01

    A 1 W tapered amplifier requiring only 200 μW of injection power at 780 nm is presented in this paper. This is achieved by injecting the seeding light into the amplifier from its tapered side and feeding the amplified light back into the small side. The amplified spontaneous emission of the tapered amplifier is suppressed by 75 dB. The double-passed tapered laser, presented here, is extremely stable and reliable. The output beam remains well coupled to the optical fiber for a timescale of months, whereas the injection of the seed light did not require realignment for over a year of daily operation.

  6. Output characteristics of 40 kW photovoltaic power generation system in ICT; Ibaraki kosen ni okeru 40 kW taiyoko hatsuden shisutemu no shutsuryoku tokusei

    Energy Technology Data Exchange (ETDEWEB)

    Sekiguchi, N. [Ibaraki National College of Tech., Ibaraki (Japan); Tani, T. [Science University of Tokyo, Tokyo (Japan)

    1999-11-25

    The photovoltaic power generation system consists of photovoltaic array and power conditioner of the utility connected system. The photovoltaic array parallelly constitutes 18 serial 30 of the modules of 540 sheets, and there is the generating capacity of largest 40 kW. The power conditioner uses 10 kW four units, and it is tracking with function of the maximum output point. This report examined the unconformable rate of photovoltaic array maximum output operating voltage, current and power in simulation and power conditioner input. (author)

  7. New 5 kW free-piston Stirling space convertor developments

    Science.gov (United States)

    Brandhorst, Henry W., Jr.; Chapman, Peter A., Jr.

    2008-07-01

    The NASA Vision for Exploration of the moon may someday require a nuclear reactor coupled with a free-piston Stirling convertor at a power level of 30-40 kW. In the 1990s, Mechanical Technology Inc.'s Stirling Engine Systems Division (some of whose Stirling personnel are now at Foster-Miller, Inc.) developed a 25 kW free-piston Stirling Space Power Demonstrator Engine under the SP-100 program. This system consisted of two 12.5 kW engines connected at their hot ends and mounted in tandem to cancel vibration. Recently, NASA and DoE have been developing dual 55 and 80 W Stirling convertor systems for potential use with radioisotope heat sources. Total test times of all convertors in this effort exceed 120,000 h. Recently, NASA began a new project with Auburn University to develop a 5 kW, single convertor for potential use in a lunar surface reactor power system. Goals of this development program include a specific power in excess of 140 W/kg at the convertor level, lifetime in excess of five years and a control system that will safely manage the convertors in case of an emergency. Auburn University awarded a subcontract to Foster-Miller, Inc. to undertake development of the 5 kW Stirling convertor assembly. The characteristics of the design along with progress in developing the system will be described.

  8. Experimental Investigation of a Direct-drive Hall Thruster and Solar Array System at Power Levels up to 10 kW

    Science.gov (United States)

    Snyder, John S.; Brophy, John R.; Hofer, Richard R.; Goebel, Dan M.; Katz, Ira

    2012-01-01

    As NASA considers future exploration missions, high-power solar-electric propulsion (SEP) plays a prominent role in achieving many mission goals. Studies of high-power SEP systems (i.e. tens to hundreds of kilowatts) suggest that significant mass savings may be realized by implementing a direct-drive power system, so NASA recently established the National Direct-Drive Testbed to examine technical issues identified by previous investigations. The testbed includes a 12-kW solar array and power control station designed to power single and multiple Hall thrusters over a wide range of voltages and currents. In this paper, single Hall thruster operation directly from solar array output at discharge voltages of 200 to 450 V and discharge powers of 1 to 10 kW is reported. Hall thruster control and operation is shown to be simple and no different than for operation on conventional power supplies. Thruster and power system electrical oscillations were investigated over a large range of operating conditions and with different filter capacitances. Thruster oscillations were the same as for conventional power supplies, did not adversely affect solar array operation, and were independent of filter capacitance from 8 to 80 ?F. Solar array current and voltage oscillations were very small compared to their mean values and showed a modest dependence on capacitor size. No instabilities or anomalous behavior were observed in the thruster or power system at any operating condition investigated, including near and at the array peak power point. Thruster startup using the anode propellant flow as the power 'switch' was shown to be simple and reliable with system transients mitigated by the proper selection of filter capacitance size. Shutdown via cutoff of propellant flow was also demonstrated. A simple electrical circuit model was developed and is shown to have good agreement with the experimental data.

  9. A 1-kW power demonstration from the advanced free electron laser

    International Nuclear Information System (INIS)

    Sheffield, R.L.; Conner, C.A.; Fortgang, C.M.

    1997-01-01

    This is the final report of a one-year, Laboratory-Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The main objective of this project was to engineer and procure an electron beamline compatible with the operation of a 1-kW free-electron laser (FEL). Another major task is the physics design of the electron beam line from the end of the wiggler to the electron beam dump. This task is especially difficult because electron beam is expected to have 20 kW of average power and to simultaneously have a 25% energy spread. The project goals were accomplished. The high-power electron design was completed. All of the hardware necessary for high-power operation was designed and procured

  10. S-band 300 W pulsed solid state microwave amplifier development for driving high power klystrons for electron accelerators

    International Nuclear Information System (INIS)

    Mohania, Praveen; Shrivastava, Purushottam; Hannurkar, P.R.

    2005-01-01

    S-Band Microwave electron accelerators like microtrons and linear accelerators need pulsed microwaves from few megawatts to tens of megawatts to accelerator the electrons to desired energy and intensity. Klystron tube based driver amplifiers were used to drive the high power klystrons, which need microwave power from few tens of watts to 1 kW depending on tube output power and gain. A endeavour was initiated at Centre for Advanced Technology to develop state of art solid state S-band microwave amplifiers indigenously to drive the klystron tubes. A modular design approach was used and individual modules up to 160 W power levels were developed and tested. Finally combining 160 W modules will give up to 300 W output power. Several more modules can be combined to achieve even high power levels. Present paper describes the developmental efforts of 300 W S-band solid-state amplifiers and related microwave technologies. (author)

  11. "Broadband" Bioinformatics Skills Transfer with the Knowledge Transfer Programme (KTP: Educational Model for Upliftment and Sustainable Development.

    Directory of Open Access Journals (Sweden)

    Emile R Chimusa

    2015-11-01

    Full Text Available A shortage of practical skills and relevant expertise is possibly the primary obstacle to social upliftment and sustainable development in Africa. The "omics" fields, especially genomics, are increasingly dependent on the effective interpretation of large and complex sets of data. Despite abundant natural resources and population sizes comparable with many first-world countries from which talent could be drawn, countries in Africa still lag far behind the rest of the world in terms of specialized skills development. Moreover, there are serious concerns about disparities between countries within the continent. The multidisciplinary nature of the bioinformatics field, coupled with rare and depleting expertise, is a critical problem for the advancement of bioinformatics in Africa. We propose a formalized matchmaking system, which is aimed at reversing this trend, by introducing the Knowledge Transfer Programme (KTP. Instead of individual researchers travelling to other labs to learn, researchers with desirable skills are invited to join African research groups for six weeks to six months. Visiting researchers or trainers will pass on their expertise to multiple people simultaneously in their local environments, thus increasing the efficiency of knowledge transference. In return, visiting researchers have the opportunity to develop professional contacts, gain industry work experience, work with novel datasets, and strengthen and support their ongoing research. The KTP develops a network with a centralized hub through which groups and individuals are put into contact with one another and exchanges are facilitated by connecting both parties with potential funding sources. This is part of the PLOS Computational Biology Education collection.

  12. "Broadband" Bioinformatics Skills Transfer with the Knowledge Transfer Programme (KTP): Educational Model for Upliftment and Sustainable Development.

    Science.gov (United States)

    Chimusa, Emile R; Mbiyavanga, Mamana; Masilela, Velaphi; Kumuthini, Judit

    2015-11-01

    A shortage of practical skills and relevant expertise is possibly the primary obstacle to social upliftment and sustainable development in Africa. The "omics" fields, especially genomics, are increasingly dependent on the effective interpretation of large and complex sets of data. Despite abundant natural resources and population sizes comparable with many first-world countries from which talent could be drawn, countries in Africa still lag far behind the rest of the world in terms of specialized skills development. Moreover, there are serious concerns about disparities between countries within the continent. The multidisciplinary nature of the bioinformatics field, coupled with rare and depleting expertise, is a critical problem for the advancement of bioinformatics in Africa. We propose a formalized matchmaking system, which is aimed at reversing this trend, by introducing the Knowledge Transfer Programme (KTP). Instead of individual researchers travelling to other labs to learn, researchers with desirable skills are invited to join African research groups for six weeks to six months. Visiting researchers or trainers will pass on their expertise to multiple people simultaneously in their local environments, thus increasing the efficiency of knowledge transference. In return, visiting researchers have the opportunity to develop professional contacts, gain industry work experience, work with novel datasets, and strengthen and support their ongoing research. The KTP develops a network with a centralized hub through which groups and individuals are put into contact with one another and exchanges are facilitated by connecting both parties with potential funding sources. This is part of the PLOS Computational Biology Education collection.

  13. Generation of the second harmonics of Bessel light beams in a KTP crystal

    International Nuclear Information System (INIS)

    Belyi, V N; Kazak, N S; Kondratyuk, N V; Khilo, N A; Shagov, A A

    1998-01-01

    Theoretical and experimental investigations were made of the characteristic features of doubling the frequency of Bessel light beams by the oe - e interaction in a KTP crystal. All possible and scalar interactions of plane-wave components of Bessel beams were observed experimentally. The spatial structure of the second harmonic in the far zone consisted of a central spot and a concentric ring. The diffraction divergence of the central beam was weak ( ∼ 1.7 mrad). The energy conversion efficiency was ∼ 21% for a Bessel beam, which was three times higher than the efficiency of conversion of the initial laser beam. A theoretical model was based on representation of the field of the second harmonic as a superposition of Bessel beams, which provided a correct description of the observed spatial and energy characteristics of the second harmonic. (nonlinear optical phenomena and devices)

  14. Evaluation of a microwave high-power reception-conversion array for wireless power transmission

    Science.gov (United States)

    Dickinson, R. M.

    1975-01-01

    Initial performance tests of a 24-sq m area array of rectenna elements are presented. The array is used as the receiving portion of a wireless microwave power transmission engineering verification test system. The transmitting antenna was located at a range of 1.54 km. Output dc voltage and power, input RF power, efficiency, and operating temperatures were obtained for a variety of dc load and RF incident power levels at 2388 MHz. Incident peak RF intensities of up to 170 mW/sq cm yielded up to 30.4 kW of dc output power. The highest derived collection-conversion efficiency of the array was greater than 80 percent.

  15. Airborne differential absorption lidar for water vapour measurements in the upper troposphere and lower stratosphere in the spectral region around 940 nm

    Energy Technology Data Exchange (ETDEWEB)

    Poberaj, G.

    2000-07-01

    Two all-solid-state laser systems were developed and studied in detail to optimise their performance for an airborne water vapour differential absorption lidar (DIAL). Their special features are high average output powers and excellent spectral properties in the 940-nm spectral region relevant for monitoring very low water vapour contents in the upper troposphere and lower stratosphere. One system is an injection-seeded pulsed Ti:sapphire ring laser with a spectral bandwidth of 105 MHz and an average power of 1.1 W. The other system is an injection-seeded optical parametric oscillator (OPO) in a ring configuration. Using KTP as nonlinear crystal, a signal output with a spectral bandwidth of 140 MHz and an average power of 1.2 W was achieved. Both systems, the Ti:sapphire ring laser and the KTP OPO, possess spectral purity values higher than 99%. The pump source for these systems is a frequency doubled diode-pumped Nd:YAG laser operating at a repetition rate of 100 Hz. The KTP OPO system has been used as a transmitter in a new airborne water vapour DIAL instrument. For the first time, measurements of two-dimensional water vapour distributions with a high vertical (500 m) and horizontal (20 km) resolution across several potential vorticity streamers were performed. Very low water vapour mixing ratios (10-50 ppmv) and strong gradients were observed in the tropopause region. The sensitivity of the DIAL instrument in the centre of a stratospheric intrusion ranges from 3% in the near field to 12% in the far field (4 km). The first comparison experiments with in situ measuring instruments show a good agreement. Considerable differences are found between DIAL measurements and data obtained from the ECMWF operational analyses and a mesoscale numerical model. (orig.)

  16. Single frequency Nd:YLF and Nd:YVO4 laser in the red emission

    International Nuclear Information System (INIS)

    Camargo, Fabiola de Almeida

    2010-01-01

    All solid-state continuous-wave (cw) narrow emission linewidth and tunable red lasers are convenient alternative sources to bulky and expensive dye-lasers for high precision laser spectroscopy. Single-frequency operation of diode-pumped Nd:YLiF 4 and Nd:YVO 4 cw ring lasers were investigated in the 1.32 - 1.34μm range, together with their intracavity second-harmonic generation (SHG) to the red spectral range (0.65 - 0.67μm) using either BiB 3 O 6 (BiBO) or periodically-poled KTiOPO 4 (ppKTP) crystals. We report on such a single-end diode-pumped Nd:YVO 4 unidirectional red ring laser containing a type-I cut BiBO nonlinear crystal, yielding a record of 680 mW of single-longitudinal mode (SLM) red output power at 671.1nm without any intra-cavity etalon. For smooth SLM wavelength tuning over the full gain bandwidth (∼4 nm), a partially-coated (R = 40%) 100μm-thin etalon was found necessary, reducing the maximum SLM power (at 671.15 nm) to 380 mW. At 1342.5nm and with a T = 2% transmission output coupler, the laser provided an optimal 1.5W of single-frequency power. We demonstrate also optimal intracavity SHG of a Nd:YLF ring laser in the π- polarization (λ = 1321.5nm) using a ppKTP. The laser yielded 1.4 W of single frequency red power at 660.5 nm, as much as the maximum fundamental power that can be extracted from the resonator using an optimal output coupler. With a partially coated (R = 25%) thin etalon, the laser was tunable over Δλ∼ 1.6nm. (author)

  17. A 100 kW-Class Technology Demonstrator for Space Solar Power

    Science.gov (United States)

    Howell, J.; Carrington, C.; Day, G.

    2004-12-01

    A first step in the development of solar power from space is the flight demonstration of critical technologies. These fundamental technologies include efficient solar power collection and generation, power management and distribution, and thermal management. In addition, the integration and utilization of these technologies into a viable satellite bus could provide an energy-rich platform for a portfolio of payload experiments such as wireless power transmission (WPT). This paper presents the preliminary design of a concept for a 100 kW-class free-flying platform suitable for flight demonstration of Space Solar Power (SSP) technology experiments.

  18. High-power fiber-coupled 100W visible spectrum diode lasers for display applications

    Science.gov (United States)

    Unger, Andreas; Küster, Matthias; Köhler, Bernd; Biesenbach, Jens

    2013-02-01

    Diode lasers in the blue and red spectral range are the most promising light sources for upcoming high-brightness digital projectors in cinemas and large venue displays. They combine improved efficiency, longer lifetime and a greatly improved color space compared to traditional xenon light sources. In this paper we report on high-power visible diode laser sources to serve the demands of this emerging market. A unique electro-optical platform enables scalable fiber coupled sources at 638 nm with an output power of up to 100 W from a 400 μm NA0.22 fiber. For the blue diode laser we demonstrate scalable sources from 5 W to 100 W from a 400 μm NA0.22 fiber.

  19. Wireless (Power Transfer Transmission of Electrical Energy (Electricity Intended for Consumer Purposes up to 50 W

    Directory of Open Access Journals (Sweden)

    Marek Piri

    2016-01-01

    Full Text Available This project deals with Power Semiconductor Systems PSS for wireless transmission of electricity to the power of 50~W with regard to the distance and transmission efficiency. We decided to use electromagnetic resonance for electrical energy transmission. For experimental verification, we have wound two coils of identical dimensions. At a given power transmission solutions, we obtain the highest efficiency η = 70% at a distance of 5 cm, where the transmitted power was 48 W.

  20. 10 kW Contactless Power Transfer System for Rapid Charger of Electric Vehicle

    OpenAIRE

    Yamanaka, Tomohiro; Kaneko, Yasuyoshi; Abe, Shigeru; Yasuda, Tomio

    2012-01-01

    A contactless power transfer system for charging electric vehicles requires a high efficiency, a large air gap, and a good tolerance to lateral misalignment and needs to be compact and lightweight. A double-sided winding 10 kW transformer based on a 1.5 kW H-shaped core transformer was developed for a rapid charger. Even though the transformer capacity was increased, the dimensions of the 10 kW transformer were almost the same as those of the 1.5 kW transformer. In this paper, the design conc...

  1. Development of a 0.1 kW thermoelectric power generator for military applications

    International Nuclear Information System (INIS)

    Menchen, W.R.

    1986-01-01

    A man-portable thermoelectric power source is being developed for the U.S. Army. Initially used as a dedicated power supply for the XM-21 Chemical Agent Alarm System, the set can also meet a variety of general purpose user requirements. Development of a thermoelectric power conversion device is being undertaken by the U.S. Army LABCOM Electronics Technology and Devices Laboratory to fill a need for a generator that is silent, lightweight, multi-fueled and reliable. The 0.1 kW Power Generator is rectangular in configuration and consists of a power module, electronic control assembly and fuel delivery system housed within a tubular structural frame. The generator operates on military fuels ranging from kerosene to diesel oil. Multi-fuel capability is achieved using an ultrasonic atomizer and regenerative burner developed specifically for this application. This paper provides the first public presentation of results achieved during the Advanced Development Phase of the 0.1 kW Power Generator. The development process is briefly traced with emphasis on a description of the system and test results obtained to date

  2. Compact Source of Electron Beam with Energy of 200 kEv and Average Power of 2 kW

    CERN Document Server

    Kazarezov, Ivan; Balakin, Vladimir E; Bryazgin, Alex; Bulatov, Alexandre; Glazkov, Ivan; Kokin, Evgeny; Krainov, Gennady; Kuznetsov, Gennady I; Molokoedov, Andrey; Tuvik, Alfred

    2005-01-01

    The paper describes a compact electron beam source with average electron energy of 200 keV. The source operates with pulse power up to 2 MW under average power not higher than 2 kW, pulsed beam current up to 10 A, pulse duration up to 2 mks, and repetition rate up to 5 kHz. The electron beam is extracted through aluminium-beryllium alloy foil. The pulse duration and repetition rate can be changed from control desk. High-voltage generator for the source with output voltage up to 220 kV is realized using the voltage-doubling circuit which consists of 30 sections. The insulation type - gas, SF6 under pressure of 8 atm. The cooling of the foil supporting tubes is provided by a water-alcohol mixture from an independent source. The beam output window dimensions are 180?75 mm, the energy spread in the beam +10/-30%, the source weight is 80 kg.

  3. [Laservaporization of the prostate: current status of the greenlight and diode laser].

    Science.gov (United States)

    Rieken, M; Bachmann, A; Gratzke, C

    2013-03-01

    In the last decade laser vaporization of the prostate has emerged as a safe and effective alternative to transurethral resection of the prostate (TURP). This was facilitated in particular by the introduction of photoselective vaporization of the prostate (PVP) with a 532 nm 80 W KTP laser in 2002. Prospective randomized trials comparing PVP and TURP with a maximum follow-up of 3 years mostly demonstrated comparable functional results. Cohort studies showed a safe application of PVP in patients under oral anticoagulation and with large prostates. Systems from various manufacturers with different maximum power output and wavelengths are now available for diode laser vaporization of the prostate. Prospective randomized trials comparing diode lasers and TURP are not yet available. In cohort studies and comparative studies PVP diode lasers are characterized by excellent hemostatic properties but functional results vary greatly with some studies reporting high reoperation rates.

  4. 77 FR 42301 - W Power, LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for...

    Science.gov (United States)

    2012-07-18

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER12-2219-000] W Power, LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for Blanket Section 204 Authorization This is a supplemental notice in the above-referenced proceeding, of W Power, LLC's application...

  5. Resonant High Power Combiners

    CERN Document Server

    Langlois, Michel; Peillex-Delphe, Guy

    2005-01-01

    Particle accelerators need radio frequency sources. Above 300 MHz, the amplifiers mostly used high power klystrons developed for this sole purpose. As for military equipment, users are drawn to buy "off the shelf" components rather than dedicated devices. IOTs have replaced most klystrons in TV transmitters and find their way in particle accelerators. They are less bulky, easier to replace, more efficient at reduced power. They are also far less powerful. What is the benefit of very compact sources if huge 3 dB couplers are needed to combine the power? To alleviate this drawback, we investigated a resonant combiner, operating in TM010 mode, able to combine 3 to 5 IOTs. Our IOTs being able to deliver 80 kW C.W. apiece, combined power would reach 400 kW minus the minor insertion loss. Values for matching and insertion loss are given. The behavior of the system in case of IOT failure is analyzed.

  6. Engineering aspects of a thermal control subsystem for the 25 kW power module

    Science.gov (United States)

    Schroeder, P. E.

    1979-01-01

    The paper presents the key trade study results, analysis results, and the recommended thermal control approach for the 25 kW power module defined by NASA. Power conversion inefficiencies and component heat dissipation results in a minimum heat rejection requirement of 9 kW to maintain the power module equipment at desired temperature levels. Additionally, some cooling capacity should be provided for user payloads in the sortie and free-flying modes. The baseline thermal control subsystem includes a dual-loop-pumped Freon-21 coolant with the heat rejected from deployable existing orbiter radiators. Thermal analysis included an assessment of spacecraft orientations, radiator shapes and locations, and comparison of hybrid heat pipe and all liquid panels.

  7. High-Bandwidth, High-Efficiency Envelope Tracking Power Supply for 40W RF Power Amplifier Using Paralleled Bandpass Current Sources

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael Andreas E.

    2005-01-01

    This paper presents a high-performance power conversion scheme for power supply applications that require very high output voltage slew rates (dV/dt). The concept is to parallel 2 switching bandpass current sources, each optimized for its passband frequency space and the expected load current....... The principle is demonstrated with a power supply, designed for supplying a 40 W linear RF power amplifier for efficient amplification of a 16-QAM modulated data stream...

  8. Linearization and efficiency enhancement techniques for silicon power amplifiers from RF to mmW

    CERN Document Server

    Kerhervé, Eric

    2015-01-01

    This book provides an overview of current efficiency enhancement and linearization techniques for silicon power amplifier designs. It examines the latest state of the art technologies and design techniques to address challenges for RF cellular mobile, base stations, and RF and mmW WLAN applications. Coverage includes material on current silicon (CMOS, SiGe) RF and mmW power amplifier designs, focusing on advantages and disadvantages compared with traditional GaAs implementations. With this book you will learn: The principles of linearization and efficiency improvement techniquesThe arch

  9. Design and Characterization of a 6 W GaN HEMT Microwave Power Amplifier with Digital Predistortion Linearization

    OpenAIRE

    Mitrevski, Dragan

    2011-01-01

    In this thesis, characterization of a 6W GaN HEMT power amplifier for optimal operating conditions through load pull simulations and measurements is investigated.The purpose is to find source and load impedances to achieve for instance maximum efficiency and maximum output power, and investigate whether thesimulated results can be replicated in a measurement setup. Simulations show that when matching for maximum output power, a peak output power of 13W is achieved, while in 1 dB compression, ...

  10. JAERI 10kW High Power ERL-FEL and Its Applications in Nuclear Energy Industries

    CERN Document Server

    Minehara, E J; Iijima, H; Kikuzawa, N; Nagai, R; Nishimori, N; Nishitani, T; Sawamura, M; Yamauchi, T

    2005-01-01

    The JAERI high power ERL-FEL has been extended to the more powerful and efficient free-electron laser (FEL) than 10kW for nuclear energy industries, and other heavy industries like defense, shipbuilding, chemical industries, environmental sciences, space-debris, and power beaming and so on. In order to realize such a tunable, highly-efficient, high average power, high peak power and ultra-short pulse FEL, we need the efficient and powerful FEL driven by the JAERI compact, stand-alone and zero boil-off super-conducting RF linac with an energy-recovery geometry. Our discussions on the ERL-FEL will cover the current status of the 10kW upgrading and its applications of non-thermal peeling, cutting, and drilling to decommission the nuclear power plants, and to demonstrate successfully the proof of principle prevention of cold-worked stress-corrosion cracking failures in nuclear power reactors under routine operation using small cubic low-Carbon stainless steel samples.

  11. High power ECCD experiments at W7-AS

    International Nuclear Information System (INIS)

    Maassberg, H.; Geiger, J.; Laqua, H.; Marushchenko, N.B.; Wendland, C.; Rome, M.

    2001-01-01

    At the W7-AS stellarator, high power electron cyclotron current drive (ECCD) experiments are analyzed. In these net-current-free discharges, the ECCD as well as the bootstrap current are feedback controlled by an inductive current. Based on measured profiles, the neoclassical predictions for the bootstrap and the inductive current densities as well as the ECCD from the linear adjoint approach with trapped particles included are calculated, and the current balance is checked. Launch-angle scans at fixed density as well as density scans at fixed launch-angle are described. (author)

  12. Pressure-assisted reaction bonding between W and Si80Ge20 alloy with Ni as the interlayer

    International Nuclear Information System (INIS)

    Xu, Y.; Laabs, F.C.; Beaudry, B.J.; Gschneidner, K.A. Jr.

    1991-01-01

    The conditions and reaction mechanism of W/Ni/Si 80 Ge 20 hot-press bonding have been studied. It was found that a Ni/Si 80 Ge 20 bond can be formed using low pressure, 19.6 MPa, in the temperature range between 780 and 900 degree C in a short time. The kinetics follows a parabolic pattern, suggesting it is a diffusion-controlled process. The activation energy is 2.7 eV and the parabolic rate constant is given by K P = 4.0 x 10 14 exp(-3.2x10 4 /T) (μm 2 /min). The bonding interface has a multilayered structure. A phenomenological mechanism of the bonding formation has been proposed based on scanning electron microscopy observations and energy dispersive spectroscopy. The cracking problem due to thermal stress is discussed based on Oxx's equation. It was found that bonds free from cracks in the Si 80 Ge 20 alloy are formed when the Ni consumption (as measured by the thickness of the nickel layer) is sufficiently small ( 4 . As an interlayer, nickel can join the tungsten sheet and the Si 80 Ge 20 together. It has been also demonstrated that a thin nickel layer formed by vapor deposition on a tungsten sheet may be used as the interlayer in place of nickel sheet

  13. Performance of the TJ-II ECRH system with the new -80 kV 50 A high voltage power supply

    International Nuclear Information System (INIS)

    Fernandez, A.; de la Fuente, J.M.; Ganuza, D.; Kirpitchev, I.; Alonso, J.; Garcia, F.; Ascasibar, E.; del Rio, J.M.; Garcia, I.; Ros, A.; Alvarez, P.; Tolkachev, A.; Catalan, G.

    2009-01-01

    The ECRH system of the TJ-II stellarator consists of two triode - 53.2 GHz - gyrotrons, which can deliver a maximum power of 300 kW each, during 1 s. Both gyrotrons are fed by a common high voltage power supply (HVPS). During the last experimental campaigns the performance of the gyrotrons were limited by the HVPS, whose maximum output current was limited to 30 A and the ripple level of the output voltage was around 7%. In order to guarantee the reliability of the ECRH system and to improve its performance, a new HVPS has been developed and manufactured by the company JEMA and was commissioned at CIEMAT during 2007. The design is based on solid-state technology and high frequency commutation techniques. The new unit reaches -80 kV and 50 A during a maximum pulse length of 1 s. The complete design, testing and commissioning of the HVPS are presented, as well as the routine operation of the ECRH system during the TJ-II experimental campaign.

  14. Performance of the TJ-II ECRH system with the new -80 kV 50 A high voltage power supply

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, A. [Laboratorio Nacional de Fusion, EURATOM-CIEMAT Association, Avda. Complutense 22, 28040 Madrid (Spain)], E-mail: angela.curto@ciemat.es; de la Fuente, J.M.; Ganuza, D. [Grupo JEMA, Paseo del Circuito 10, 20160 Lasarte-Oria (Spain); Kirpitchev, I.; Alonso, J. [Laboratorio Nacional de Fusion, EURATOM-CIEMAT Association, Avda. Complutense 22, 28040 Madrid (Spain); Garcia, F. [Grupo JEMA, Paseo del Circuito 10, 20160 Lasarte-Oria (Spain); Ascasibar, E. [Laboratorio Nacional de Fusion, EURATOM-CIEMAT Association, Avda. Complutense 22, 28040 Madrid (Spain); del Rio, J.M.; Garcia, I. [Grupo JEMA, Paseo del Circuito 10, 20160 Lasarte-Oria (Spain); Ros, A.; Alvarez, P.; Tolkachev, A.; Catalan, G. [Laboratorio Nacional de Fusion, EURATOM-CIEMAT Association, Avda. Complutense 22, 28040 Madrid (Spain)

    2009-06-15

    The ECRH system of the TJ-II stellarator consists of two triode - 53.2 GHz - gyrotrons, which can deliver a maximum power of 300 kW each, during 1 s. Both gyrotrons are fed by a common high voltage power supply (HVPS). During the last experimental campaigns the performance of the gyrotrons were limited by the HVPS, whose maximum output current was limited to 30 A and the ripple level of the output voltage was around 7%. In order to guarantee the reliability of the ECRH system and to improve its performance, a new HVPS has been developed and manufactured by the company JEMA and was commissioned at CIEMAT during 2007. The design is based on solid-state technology and high frequency commutation techniques. The new unit reaches -80 kV and 50 A during a maximum pulse length of 1 s. The complete design, testing and commissioning of the HVPS are presented, as well as the routine operation of the ECRH system during the TJ-II experimental campaign.

  15. Performance tests of the 600-kW cw, 80-MHz, radio-frequency systems for the FMIT accelerator

    International Nuclear Information System (INIS)

    Nylander, R.F.; Bacci, F.F.; Fazio, M.V.; Rodgers, J.D.

    1983-01-01

    The high-power rf system for the Fusion Materials Irradiation Test (FMIT) accelerator consists of 14 sets of equipment,** each of which can deliver up to 600 kW (cw) at 80 MHz into a load having a VSWR of 1.4 or less (any phase). The equipment was designed and constructed to FMIT specifications by Continental Electronics Mfg. Co. (CEMC) of Dallas, Texas. Four sets have been shipped to Los Alamos for use with the accelerator (two with the radio-frequency quadrupole (RFQ) and two with the drift-tube linac (DTL)). The first set was fully tested at CEMC; results are summarized. Further tests conducted at Los Alamos, both into a resistive (electrolytic) load and into a resonant cavity (Q about 21,000), have confirmed that this system meets, and in most cases far exceeds, the specified performance limits. The first of the 13 production sets also was tested at CEMC before shipping any of the rf equipment to the Hanford Engineering and Development Laboratory at Richland, Washington. Because of the differences in behavior observed when No. 1 was operated at Los Alamos with a different tube installed in the final power amplifier (FPA) cavity, CEMC agreed to test No. 5 with two tubes having widely differing characteristics (notably primary screen emission). As expected, behavior differed markedly, and some design modification was necessary to meet all specifications with either tube. Results of final performance tests on No. 5 are summarized. As noted in the table, detailed test results are presented in the CEMC Acceptance Test Reports (ATRs) dated April 7, 1982 and January 3, 1983. Discussion of the most significant aspects of CEMC's tests and of those performed at Los Alamos follows a brief description of the equipment

  16. Power ramp rate capabilities of a 5 kW proton exchange membrane fuel cell system with discrete ejector control

    Science.gov (United States)

    Nikiforow, K.; Pennanen, J.; Ihonen, J.; Uski, S.; Koski, P.

    2018-03-01

    The power ramp rate capabilities of a 5 kW proton exchange membrane fuel cell (PEMFC) system are studied theoretically and experimentally for grid support service applications. The fuel supply is implemented with a fixed-geometry ejector and a discrete control solution without any anode-side pressure fluctuation suppression methods. We show that the stack power can be ramped up from 2.0 kW to 4.0 kW with adequate fuel supply and low anode pressure fluctuations within only 0.1 s. The air supply is implemented with a centrifugal blower. Air supply ramp rates are studied with a power increase executed within 1 and 0.2 s after the request, the time dictated by grid support service requirements in Finland and the UK. We show that a power ramp-up from 2.0 kW to 3.7 kW is achieved within 1 s with an initial air stoichiometry of 2.5 and within 0.2 s with an initial air stoichiometry of 7.0. We also show that the timing of the power ramp-up affects the achieved ancillary power capacity. This work demonstrates that hydrogen fueled and ejector-based PEMFC systems can provide a significant amount of power in less than 1 s and provide valuable ancillary power capacity for grid support services.

  17. Pico-level DNA sensing by hetero-polymetalate, Na10{Dy2W10O30(µ-S)6}·80H2O, cluster

    Science.gov (United States)

    Dutta, Taposhree; Ganguly, Jhuma; Sarkar, Sabyasachi

    2018-04-01

    The polyoxometalate dysprosium cluster, (Dy-S-W POM) , Na10[Dy2W10O30(µ-S)6]·80H2O, shows remarkable dsDNA denaturation property. In the presence of 0.22 µmol of this Dy-S-W POM, the melting temperature (Tm) of calf-thymus (CT) dsDNA is decreased to 62.35 °C. Dy-S-W POM shows bleaching of methylene blue (MB). Addition of CT-DNA in the MB bleached solution of Dy-S-W POM apparently intercalates MB. Such trapped MB by CT-DNA responds to its re-oxidation by elemental sulfur formed in the bleaching process involving Dy-S-W POM. This reduction-oxidation property of MB with Dy-S-W POM led to the detection of pico (13.20 pmol) level of DNA even by naked eye, which will be helpful for rapid trace DNA detection in forensic science and DNA-related diagnostics, complimenting time-consuming sophisticated methodology.

  18. Design and Control of a 3 kW Wireless Power Transfer System for Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Zhenshi Wang

    2015-12-01

    Full Text Available This paper aims to study a 3 kW wireless power transfer system for electric vehicles. First, the LCL-LCL topology and LC-LC series topology are analyzed, and their transfer efficiencies under the same transfer power are compared. The LC-LC series topology is validated to be more efficient than the LCL-LCL topology and thus is more suitable for the system design. Then a novel q-Zsource-based online power regulation method which employs a unique impedance network (two pairs of inductors and capacitors to couple the cascaded H Bridge to the power source is proposed. By controlling the shoot-through state of the H Bridge, the charging current can be adjusted, and hence, transfer power. Finally, a prototype is implemented, which can transfer 3 kW wirelessly with ~95% efficiency over a 20 cm transfer distance.

  19. Dual-Polarized Antenna Arrays with CMOS Power Amplifiers for SiP Integration at W-Band

    Science.gov (United States)

    Giese, Malte; Vehring, Sönke; Böck, Georg; Jacob, Arne F.

    2017-09-01

    This paper presents requirements and front-end solutions for low-cost communication systems with data rates of 100 Gbit/s. Link budget analyses in different mass-market applications are conducted for that purpose. It proposes an implementation of the front-end as an active antenna array with support for beam steering and polarization multiplexing over the full W-band. The critical system components are investigated and presented. This applies to a transformer coupled power amplifier (PA) in 40 nm bulk CMOS. It shows saturated output power of more than 10 dBm and power-added-efficiency of more than 10 % over the full W-band. Furthermore, the performance of microstrip-to-waveguide transitions is shown exemplarily as an important part of the active antenna as it interfaces active circuitry and antenna in a polymer-and-metal process. The transition test design shows less than 0.9 dB insertion loss and more than 12 dB return loss for the differential transition over the full W-band.

  20. Prediction of Critical Power and W' in Hypoxia: Application to Work-Balance Modelling.

    Science.gov (United States)

    Townsend, Nathan E; Nichols, David S; Skiba, Philip F; Racinais, Sebastien; Périard, Julien D

    2017-01-01

    Purpose: Develop a prediction equation for critical power (CP) and work above CP (W') in hypoxia for use in the work-balance ([Formula: see text]) model. Methods: Nine trained male cyclists completed cycling time trials (TT; 12, 7, and 3 min) to determine CP and W' at five altitudes (250, 1,250, 2,250, 3,250, and 4,250 m). Least squares regression was used to predict CP and W' at altitude. A high-intensity intermittent test (HIIT) was performed at 250 and 2,250 m. Actual and predicted CP and W' were used to compute W' during HIIT using differential ([Formula: see text]) and integral ([Formula: see text]) forms of the [Formula: see text] model. Results: CP decreased at altitude ( P equations for CP and W' developed in this study are suitable for use with the [Formula: see text] model in acute hypoxia. This enables the application of [Formula: see text] modelling to training prescription and competition analysis at altitude.

  1. Development and experiment of a 60 kW horizontal-axis marine current power system

    International Nuclear Information System (INIS)

    Xu, Quan-kun; Liu, Hong-wei; Lin, Yong-gang; Yin, Xiu-xing; Li, Wei; Gu, Ya-jing

    2015-01-01

    A 60 kW horizontal-axis marine current power system is designed, built and tested to provide potentially cost-competitive electrical power for residents in remote islands. This power system mainly consists of a three-bladed marine current turbine, a drive-train system, power electronics and a control console. The turbine blade parameters are reasonably calculated and optimized based on the blade element momentum theory. The hydrodynamic performances of this turbine are predicted over a wide range of operating conditions. An adequate drive-train system is carefully designed to make the marine power system work smoothly and quietly even under harsh marine current conditions. The control console is also developed to facilitate the condition monitoring and generator power and speed regulations for this power system by adequately controlling the onshore power electronics. This power system has been tested under real marine current conditions to thoroughly evaluate its dynamic characteristics and effectiveness. - Highlights: • A 60°kW horizontal-axis marine current power system is designed, built and tested. • Detailed design procedure and experimental data are provided. • Experimental results demonstrate high power convention efficiency of the system

  2. Thermal power calibration of the TRIGA Mark I IPR-R1 reactor during the upgrading tests to 250 kW

    International Nuclear Information System (INIS)

    Mesquita, Amir Zacarias; Maretti, Fausto Junior; Rezende, Hugo Cesar

    2002-01-01

    This paper presents the results and the methodology used to calibrate the thermal power of the TRIGA MARK I IPR-R1 Reactor in CDTN, Belo Horizonte, Brazil. This calibration was realized during the operation tests carried out to allow the reactor power upgrade from the current 100 kW to 250 kW. The methodology consisted in the measurement of the inlet and outlet temperature and the water flow in the primary cooling loop. The thermal balance together with the thermal losses gave the thermal power. There were made three sequences of tests. The first rising of the thermal power was made with the usual configuration of the core (59 fuel elements). After the changing of the ion chambers position and the control rod and the increase of the number of fuels (63 fuel elements), a new evaluation of the thermal power was accomplished, having been obtained a thermal power of 234 kW, for an indication of 250 kW in the lineal channel. After the return of the core to the initial configuration (59 fuel elements), it took place a new test, getting back the reactor to the power level of 100 kW. (author)

  3. Measurements of the W boson mass at the Tevatron

    International Nuclear Information System (INIS)

    Hays, C.P.

    2014-01-01

    Precise measurements of the W boson mass W test the contributions of loop corrections to the W boson propagator from e.g. the top and bottom quarks and the Higgs boson. New measurements from CDF [m W =80.387±0.012(stat)±0.015(syst) GeV] and D0 [m W =80.375±0.011(stat)±0.020(syst) GeV] are the most precise to date, significantly tightening the constraints on loops in the W boson propagator. The new world-average value of the W boson mass is m W =80.385±0.015 GeV. (author)

  4. High-power diode-end-pumped Tm:YLF slab laser delivering 189 W at 1890 nm

    CSIR Research Space (South Africa)

    Koen, W

    2010-09-01

    Full Text Available Laser Delivering 189 W at 1890 nm W. Koen, H.J. Strauss, C. Bollig and M.J.D. Esser CSIR National Laser Centre, Meiring Naude Road, Brummeria, Pretoria, 0001 wkoen@csir.co.za Abstract: We present a high-power Tm:YLF slab laser double...

  5. Measurement of the W boson mass

    International Nuclear Information System (INIS)

    Abe, F.; Albrow, M.G.; Amendolia, S.R.; Amidei, D.; Antos, J.; Anway-Wiese, C.; Apollinari, G.; Areti, H.; Atac, M.; Auchincloss, P.; Azfar, F.; Azzi, P.; Bacchetta, N.; Badgett, W.; Bailey, M.W.; Bao, J.; de Barbaro, P.; Barbaro-Galtieri, A.; Barnes, V.E.; Barnett, B.A.; Bartalini, P.; Bauer, G.; Baumann, T.; Bedeschi, F.; Behrends, S.; Belforte, S.; Bellettini, G.; Bellinger, J.; Benjamin, D.; Benlloch, J.; Bensinger, J.; Benton, D.; Beretvas, A.; Berge, J.P.; Bertolucci, S.; Bhatti, A.; Biery, K.; Binkley, M.; Bird, F.; Bisello, D.; Blair, R.E.; Blocker, C.; Bodek, A.; Bokhari, W.; Bolognesi, V.; Bortoletto, D.; Boswell, C.; Boulos, T.; Brandenburg, G.; Bromberg, C.; Buckley-Geer, E.; Budd, H.S.; Burkett, K.; Busetto, G.; Byon-Wagner, A.; Byrum, K.L.; Cammerata, J.; Campagnari, C.; Campbell, M.; Caner, A.; Carithers, W.; Carlsmith, D.; Castro, A.; Cen, Y.; Cervelli, F.; Chao, H.Y.; Chapman, J.; Cheng, M.; Chiarelli, G.; Chikamatsu, T.; Chiou, C.N.; Christofek, L.; Cihangir, S.; Clark, A.G.; Cobal, M.; Contreras, M.; Conway, J.; Cooper, J.; Cordelli, M.; Couyoumtzelis, C.; Crane, D.; Cunningham, J.D.; Daniels, T.; DeJongh, F.; Delchamps, S.; Dell'Agnello, S.; Dell'Orso, M.; Demortier, L.; Denby, B.; Deninno, M.; Derwent, P.F.; Devlin, T.; Dickson, M.; Dittmann, J.R.; Donati, S.; Drucker, R.B.; Dunn, A.; Einsweiler, K.; Elias, J.E.; Ely, R.; Engels, E. Jr.; Eno, S.; Errede, D.; Errede, S.; Fan, Q.; Farhat, B.; Fiori, I.; Flaugher, B.; Foster, G.W.; Franklin, M.; Frautschi, M.; Freeman, J.; Friedman, J.; Frisch, H.; Fry, A.; Fuess, T.A.; Fukui, Y.; Funaki, S.; Gagliardi, G.; Galeotti, S.; Gallinaro, M.; Garfinkel, A.F.; Geer, S.; Gerdes, D.W.; Giannetti, P.; Giokaris, N.; Giromini, P.; Gladney, L.; Glenzinski, D.; Gold, M.; Gonzalez, J.; Gordon, A.; Goshaw, A.T.; Goulianos, K.; Grassmann, H.; Grewal, A.; Groer, L.; Grosso-Pilcher, C.; Haber, C.; Hahn, S.R.; Hamilton, R.; Handler, R.; Hans, R.M.; Hara, K.; Harral, B.; Harris, R.M.; Hauger, S.A.

    1995-01-01

    We present a measurement of the mass of the W boson using data collected with the Collider Detector at Fermilab during the 1992--93 collider run at the Fermilab Tevatron. A fit to the transverse mass spectrum of a sample of 3268 W→μν events recorded in an integrated luminosity of 19.7pb -1 gives a mass M W μ =80.310±0.205(stat)±0.130(syst)GeV/c 2 . A fit to 5718 W→eν events recorded in 18.2 pb --1 gives M e W =80.490±0.145(stat)±0.175(syst)GeV/c 2 . Combining these results, accounting for correlated uncertainties, yields M W =80.410±0.180GeV/c 2

  6. Study of Contactless Power Supply for Spindle Ultrasonic Vibrator

    Science.gov (United States)

    Chen, T. R.; Lee, Y. L.; Liu, H. T.; Chen, S. M.; Chang, H. Z.

    2017-11-01

    In this study, a contactless power supply for the ultrasonic motor on the spindle is proposed. The proposed power supply is composed of a series-parallel resonant circuit and a cylindrical contactless transformer. Based on the study and rotation experiments, it can be seen that the proposed power supply can both provide a stable ac power with 25 kHz / 70 V to the ultrasonic motor. When the output power is 250 W, the efficiency of the proposed supply is 89.8 % in respectively rotation tests. When the output power is more than 150 W, the efficiency of the proposed supply is higher than 80 % within the rated output power range.

  7. 40 CFR 86.129-80 - Road load power, test weight, and inertia weight class determination.

    Science.gov (United States)

    2010-07-01

    ... inertia weight class determination. 86.129-80 Section 86.129-80 Protection of Environment ENVIRONMENTAL... power, test weight, and inertia weight class determination. (a) Flywheels, electrical or other means of... weight (pounds) Equivalent test weight (pounds) Inertia weight class (pounds) Up to 1,062 1,000 1,000 1...

  8. MoXy fiber with active cooling cap for bovine prostate vaporization with high power 200W 532 nm laser

    Science.gov (United States)

    Peng, Steven Y.; Kang, Hyun Wook; Pirzadeh, Homa; Stinson, Douglas

    2011-03-01

    A novel MoXyTM fiber delivery device with Active Cooling Cap (ACCTM) is designed to transmit up to 180W of 532 nm laser light to treat benign prostatic hyperplasia (BPH). Under such high power tissue ablation, effective cooling is key to maintaining fiber power transmission and ensuring the reliability of the fiber delivery device To handle high power and reduce fiber degradation, the MoXy fiber features a larger core size (750 micrometer) and an internal fluid channel to ensure better cooling of the fiber tip to prevent the cap from burning, detaching, or shattering during the BPH treatment. The internal cooling channel was created with a metal cap and tubing that surrounds the optical fiber. In this study MoXy fibers were used to investigate the effect of power levels of 120 and 200 W on in-vitro bovine prostate ablation using a 532 nm XPSTM laser system. For procedures requiring more than 100 kJ, the MoXy fiber at 200W removed tissue at twice the rate of the current HPS fiber at 120W. The fiber maintained a constant tissue vaporization rate during the entire tissue ablation process. The coagulation at 200W was about 20% thicker than at 120W. In conclusion, the new fibers at 200W doubled the tissue removal rate, maintained vaporization efficiency throughout delivery of 400kJ energy, and induced similar coagulation to the existing HPS fiber at 120W.

  9. Field Trial on a Rack-mounted DC Power Supply System with 80-Ah Lithium-ion Batteries

    Science.gov (United States)

    Matsushima, Toshio

    Using an industrial lithium-ion battery that has higher energy density than conventional valve-regulated lead-acid batteries, a rack-mounted DC-power-supply system was assembled and tested at a base transceiver station (BTS) offering actual services. A nominal output voltage and maximum output current of the system is 53.5V and 20A, respectively. An 80-Ah lithium-ion battery composed of 13 cells connected in series was applied in the system and maintained in a floating charge method. The DC-power-supply system was installed in a 19-inch power rack in the telecommunications equipment box at BTS. The characteristics of the 80Ah lithium-ion battery, specifications of the DC-power-supply system and field-test results were shown in this paper.

  10. kW-class direct diode laser for sheet metal cutting based on commercial pump modules

    Science.gov (United States)

    Witte, U.; Schneider, F.; Holly, C.; Di Meo, A.; Rubel, D.; Boergmann, F.; Traub, M.; Hoffmann, D.; Drovs, S.; Brand, T.; Unger, A.

    2017-02-01

    We present a direct diode laser with an optical output power of more than 800 W ex 100 μm with an NA of 0.17. The system is based on 6 commercial pump modules that are wavelength stabilized by use of VBGs. Dielectric filters are used for coarse and dense wavelength multiplexing. Metal sheet cutting tests were performed in order to prove system performance and reliability. Based on a detailed analysis of loss mechanisms, we show that the design can be easily scaled to output powers in the range of 2 kW and to an optical efficiency of 80%.

  11. Floating nuclear power station of APWS-80 type for electricity generation and fresh water production

    International Nuclear Information System (INIS)

    Zverev, K.V.; Polunichev, V.I.; Sergeev, Yu.A.

    1997-01-01

    To solve the problem of seawater desalination and electric energy generation, the designing organizations of Russia have developed two variants of floating nuclear desalination plant. The KLT-40 type reactors, with maximum 160 MW thermal power, is used as the power source for such plant. Depending on the customer requirement one or two power unit could be installed in the floating desalination plant. There are APWS-80 with two reactors, producing 80,000 m 3 desalinated water per day and APWS-40 with one reactor, producing 40,000 m 3 desalinated water per day. The advantages of floating desalination plants are the possibility to build and test them at the ship-build plant of the supplier country and to hand them over on turnkey base. (author). 5 figs

  12. Control interlock and monitoring system for 80 KW IOT based RF power amplifier system at 505.812 MHz for Indus-2

    International Nuclear Information System (INIS)

    Kumar, Gautam; Deo, R.K.; Jain, M.K.; Bagre, Sunil; Hannurkar, P.R.

    2013-01-01

    For 80 kW inductive output tube (IOT) based RF power amplifier system at 505.812 MHz for Indus-2, a control, interlock and monitoring system is realized. This is to facilitate proper start-up and shutdown of the amplifier system, monitor various parameters to detect any malfunction during its operation and to bring the system in a safe stage, thereby assuring reliable operation of the amplifier system. This high power amplifier system incorporates interlocks such as cooling interlocks, various voltage and current interlocks and time critical RF interlocks. Processing of operation sequence, cooling interlocks and various voltage and current interlocks have been realized by using Siemens make S7-CPU-315-2DP (CPU) based programmable logic controller (PLC) system. While time critical or fast interlocks have been realized by using Siemens make FPGA based Boolean Co-processor FM-352-5 which operates in standalone mode. Siemens make operating panel OP277 6'' is being used as a human machine interface (HMI) device for command, data, alarm generation and process parameter monitoring. (author)

  13. Effect of target power on the physical properties of Ti thin films prepared by DC magnetron sputtering with supported discharge

    Directory of Open Access Journals (Sweden)

    Kavitha A.

    2017-02-01

    Full Text Available The present paper describes the effect of target power on the properties of Ti thin films prepared by DC magnetron sputtering with (triode mode and without (diode mode supported discharge. The traditional diode magnetron sputtering with an addition of a hot filament has been used to sustain the discharge at a lower pressure. The effect of target power (60, 80, 100 and 120 W on the physical properties of Ti thin films has been studied in diode and triode modes. XRD studies showed that the Ti thin films prepared at a target power up to 100 W in diode mode were amorphous in nature. The Ti thin films exhibited crystalline structure at much lower target power of 80 W with a preferred orientation along (0 0 2 plane. The grain size of Ti thin films prepared in triode mode increased from 64 nm to 80 nm, whereas in diode mode, the grain size increased from 2 nm to 5 nm. EDAX analysis confirmed that the incorporation of reactive gases was lower in triode mode compared to diode mode. The electrical resistivity of Ti thin films deposited in diode mode was found to be 85 µΩ⋅cm (target power 120 W. The electrical resistivity of Ti thin films in triode mode was found to be deceased to 15.2 µΩ⋅cm (target power 120 W.

  14. Fast transport changes and power degradation in the W7-AS stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Stroth, U; Giannone, L.; Hartfuss, H -J [Association Euratom-Max-Planck-Institut fuer Plasmaphysik, Garching (Germany); and others

    1996-04-01

    The turbulent heat transport in high-temperature fusion plasmas is not understood. It increases with power heating. The physical mechanism of this process is investigated in the W7-AS stellarator. The fundamental question addressed here is whether transport is governed by local plasma parameters or by a global quantity. Three different types of experiments with critical sensitivity are carried out. They can consistently be described on the basis of a non-local dependence of the transport coefficient on the global heating power. (author).

  15. Fast transport changes and power degradation in the W7-AS stellarator

    International Nuclear Information System (INIS)

    Stroth, U.; Giannone, L.; Hartfuss, H.-J.

    1996-01-01

    The turbulent heat transport in high-temperature fusion plasmas is not understood. It increases with power heating. The physical mechanism of this process is investigated in the W7-AS stellarator. The fundamental question addressed here is whether transport is governed by local plasma parameters or by a global quantity. Three different types of experiments with critical sensitivity are carried out. They can consistently be described on the basis of a non-local dependence of the transport coefficient on the global heating power. (author)

  16. 270 nm Pseudomorphic Ultraviolet Light-Emitting Diodes with Over 60 mW Continuous Wave Output Power

    Science.gov (United States)

    Grandusky, James R.; Chen, Jianfeng; Gibb, Shawn R.; Mendrick, Mark C.; Moe, Craig G.; Rodak, Lee; Garrett, Gregory A.; Wraback, Michael; Schowalter, Leo J.

    2013-03-01

    In this letter, the achievement of over 60 mW output power from pseudomorphic ultraviolet light-emitting diodes in continuous wave operation is reported. Die thinning and encapsulation improved the photon extraction efficiency to over 15%. Improved thermal management and a high characteristic temperature resulted in a low thermal rolloff up to 300 mA injection current with an output power of 67 mW, an external quantum efficiency (EQE) of 4.9%, and a wall plug efficiency (WPE) of 2.5% for a single-chip device emitting at 271 nm in continuous wave operation.

  17. Quantum-dot saturable absorber and Kerr-lens mode-locked Yb:KGW laser with >450  kW of peak power.

    Science.gov (United States)

    Akbari, R; Zhao, H; Fedorova, K A; Rafailov, E U; Major, A

    2016-08-15

    The hybrid action of quantum-dot saturable absorber and Kerr-lens mode locking in a diode-pumped Yb:KGW laser was demonstrated. Using a quantum-dot saturable absorber with a 0.7% (0.5%) modulation depth, the mode-locked laser delivered 90 fs (93 fs) pulses with 3.2 W (2.9 W) of average power at the repetition rate of 77 MHz, corresponding to 462 kW (406 kW) of peak power and 41 nJ (38 nJ) of pulse energy. To the best of our knowledge, this represents the highest average and peak powers generated to date from quantum-dot saturable absorber-based mode-locked lasers.

  18. The measurement of the W boson mass from CDF

    International Nuclear Information System (INIS)

    1994-06-01

    Recent results from LEP experiments have substantially improved the knowledge of the Z boson. However, hadron colliders remain the only source of direct measurements of the W boson. There have been measurements of the W boson mass from the UA2 and CDF collaborations. The W mass continues to be a subject of great interest in testing the Standard Model. Here, the authors have made a preliminary determination of the W boson mass M W = 80.38 ± 0.23 GeV/c 2 from a combined analysis of W → eν and W → μν in anti pp collisions at √s = 1.8 TeV. The electron data alone yields M W = 80.47 ± 0.15(stat.) ± 0.25(syst.) GeV/c 2 , while the muon data gives M W = 80.29 ± 0.20(stat.) ± 0.24(syst.) GeV/c 2

  19. Using the ultra-long pulse width pulsed dye laser and elliptical spot to treat resistant nasal telangiectasia.

    Science.gov (United States)

    Madan, Vishal; Ferguson, Janice

    2010-01-01

    Thick linear telangiectasia on the ala nasi and nasolabial crease can be resistant to treatment with the potassium-titanyl-phosphate (KTP) laser and the traditional round spot on a pulsed dye laser (PDL). We evaluated the efficacy of a 3 mm x 10 mm elliptical spot using the ultra-long pulse width on a Candela Vbeam(R) PDL for treatment of PDL- and KTP laser-resistant nasal telangiectasia. Nasal telangiectasia resistant to PDL (12 patients) and KTP laser (12 patients) in 18 patients were treated with a 3 mm x 10 mm elliptical spot on the ultra-long pulse pulsed dye laser (ULPDL) utilising long pulse width [595 nm, 40 ms, double pulse, 30:20 dynamic cooling device (DCD)]. Six patients had previously received treatment with both PDL and KTP laser prior to ULPDL (40 treatments, range1-4, mean 2.2). Complete clearance was seen in ten patients, and eight patients displayed more than 80% improvement after ULPDL treatment. Self-limiting purpura occurred with round spot PDL and erythema with KTP laser and ULPDL. Subtle linear furrows along the treatment sites were seen in three patients treated with the KTP laser. ULPDL treatment delivered using a 3 mm x 10 mm elliptical spot was non-purpuric and highly effective in the treatment of nasal telangiectasia resistant to KTP laser and PDL.

  20. 650-nm-band high-power and highly reliable laser diodes with a window-mirror structure

    Science.gov (United States)

    Shima, Akihiro; Hironaka, Misao; Ono, Ken-ichi; Takemi, Masayoshi; Sakamoto, Yoshifumi; Kunitsugu, Yasuhiro; Yamashita, Koji

    1998-05-01

    An active layer structure with 658 nm-emission at 25 degrees Celsius has been optimized in order to reduce the operating current of the laser diodes (LD) under high temperature condition. For improvement of the maximum output power and the reliability limited by mirror degradation, we have applied a zinc-diffused-type window-mirror structure which prevents the optical absorption at the mirror facet. As a result, the CW output power of 50 mW is obtained even at 80 degrees Celsius for a 650 micrometer-long window-mirror LD. In addition, the maximum light output power over 150 mW at 25 degrees Celsius has been realized without any optical mirror damage. In the aging tests, the LDs have been operating for over 2,500 - 5,000 hours under the CW condition of 30 - 50 mW at 60 degrees Celsius. The window-mirror structure also enables reliable 60 degree Celsius, 30 mW, CW operation of the LDs with 651 nm- emission at 25 degrees Celsius. Moreover, the maximum output power of around 100 mW even at 80 degrees Celsius and reliable 2,000-hour operation at 60 degrees Celsius, 70 mW have been realized for the first time by 659 nm LDs with a long cavity length of 900 micrometers.

  1. 77 FR 37031 - Don W. Gilbert Hydro Power, LLC; Notice of Application Tendered for Filing With the Commission...

    Science.gov (United States)

    2012-06-20

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 14367-001] Don W. Gilbert... No.: 14367-001. c. Date filed: May 30, 2012. d. Applicant: Don W. Gilbert Hydro Power, LLC. e. Name... Utility Regulatory Policies Act of 1978, 16 U.S.C. 2705, 2708.] h. Applicant Contact: Don W. Gilbert and...

  2. EBT-S 28-GHz, 200-kW, CW, mixed-mode, quasi-optical plasma heating system

    International Nuclear Information System (INIS)

    White, T.L.; Kimrey, H.D.; Bigelow, T.S.; Bates, D.D.; Eason, H.O.

    1984-07-01

    The ELMO Bumpy Torus-Scale (EBT-S) 28-GHz, 200-kW, cw, plasma heating system consists of a gyrotron oscillator, an oversized waveguide two-bend transmission system, and a quasi-optical mixed-mode microwave distribution manifold that feeds microwave power to the 24 plasma loads of the EBT-S fusion experiment. Balancing power to the 24 loads of the EBT-S fusion experiment. Balancing power to the 24 loads was achieved by adjusting the areas at 24 coupling irises. System performance is easily measured using system calorimetry. The distribution manifold mixed-mode power transmission, reflection, and loss coefficients are 89%, 6%, and 5%, respectively. The overall system efficiency (plasma power/gyrotron power) is 80%, but with some modifications to the distribution manifold we believe the ultimate efficiency can approach 90%. The system reliability is outstanding with a world's record 1 x 10 5 kW h of 28-GHz energy delivered to the EBT-S device with well over 1 x 10 3 operating hours

  3. 1018 nm Yb-doped high-power fiber laser pumped by broadband pump sources around 915 nm with output power above 100 W

    DEFF Research Database (Denmark)

    Midilli, Yakup; Efunbajo, Oyewole Benjamin; Şimşek, Bartu

    2017-01-01

    laser were also addressed in this study. Finally, we have tested this system for high power experimentation and obtained 67% maximum optical-to-optical efficiency at an approximately 110 W output power level. To the best of our knowledge, this is the first 1018 nm ytterbium-doped all-fiber laser pumped...

  4. Analysis of High-Power Diode Laser Heating Effects on HY-80 Steel for Laser Assisted Friction Stir Welding Applications

    Energy Technology Data Exchange (ETDEWEB)

    Wiechec, Maxwell; Baker, Brad; McNelley, Terry; Matthews, Manyalibo; Rubenchik, Alexander; Rotter, Mark; Beach, Ray; Wu, Sheldon

    2017-01-01

    In this research, several conditions of high power diode laser heated HY-80 steel were characterized to determine the viability of using such lasers as a preheating source before friction stir welding in order to reduce frictional forces thereby reducing tool wear and increasing welding speeds. Differences in microstructures within heat affected zones were identified at specific laser powers and traverse speeds. Vickers hardness values were recorded and analyzed to validate the formation of additional martensite in diode laser heated regions of HY-80 steel. Conditions that produced little to no additional martensite were identified and relationships among high power diode laser power, traverse speed, and martensite formation were determined. The development of heat affected zones, change in grain structure, and creation of additional martensite in HY-80 can be prevented through the optimization of laser amperage and transverse speed.

  5. MCD 80: A modular coupling system for power line carrier transmission

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, B; Mayer, M

    1983-05-01

    Power line carrier (PLC) links are of great importance to power supply utilities. The communications equipment is linked to the H.V. system by a coupling device. Brown Boveri have developed a new modular coupling system MCD 80 which is compact, programmable and economical. The benefit of years of experience in the field went into its development. With the new system, optimum PLC couplings, R.F. through-connections and junction networks are possible for all H.V. transmission systems. A general look at the subject of PLC couplings is followed by a closer look at the main components, such as the programmable high pass coupling unit, band pass coupling unit, hybrid, separating filter, R.F. junction network and attenuator. Some typical examples are described.

  6. A diode-pumped continuous-wave Nd:YAG laser with an average output power of 1 kW

    International Nuclear Information System (INIS)

    Lee, Sung Man; Cha, Byung Heon; Kim, Cheol Jung

    2004-01-01

    A diode-pumped Nd:YAG laser with an average output power of 1 kW is developed for industrial applications, such as metal cutting, precision welding, etc. To develop such a diode-pumped high power solid-state laser, a series of laser modules have been used in general with and without thermal birefringence compensation. For example, Akiyama et al. used three laser modules to obtain a output power of 5.4 kW CW.1 In the side-pumped Nd:YAG laser, which is a commonly used pump scheme to obtain high output power, the crystal rod has a short thermal focal length at a high input pump power, and the short thermal focal length in turn leads to beam distortion within a laser resonator. Therefore, to achieve a high output power with good stability, isotropic beam profile, and high optical efficiency, the detailed analysis of the resonator stability condition depending on both mirror distances and a crystal separation is essential

  7. Visible high power fiber coupled diode lasers

    Science.gov (United States)

    Köhler, Bernd; Drovs, Simon; Stoiber, Michael; Dürsch, Sascha; Kissel, Heiko; Könning, Tobias; Biesenbach, Jens; König, Harald; Lell, Alfred; Stojetz, Bernhard; Löffler, Andreas; Strauß, Uwe

    2018-02-01

    In this paper we report on further development of fiber coupled high-power diode lasers in the visible spectral range. New visible laser modules presented in this paper include the use of multi single emitter arrays @ 450 nm leading to a 120 W fiber coupled unit with a beam quality of 44 mm x mrad, as well as very compact modules with multi-W output power from 405 nm to 640 nm. However, as these lasers are based on single emitters, power scaling quickly leads to bulky laser units with a lot of optical components to be aligned. We also report on a new approach based on 450 nm diode laser bars, which dramatically reduces size and alignment effort. These activities were performed within the German government-funded project "BlauLas": a maximum output power of 80 W per bar has been demonstrated @ 450 nm. We show results of a 200 μm NA0.22 fiber coupled 35 W source @ 450 nm, which has been reduced in size by a factor of 25 compared to standard single emitter approach. In addition, we will present a 200 μm NA0.22 fiber coupled laser unit with an output power of 135 W.

  8. Thermal simulation for 35 kW powered prototype radio frequency quadrapole

    International Nuclear Information System (INIS)

    Kothari, Ashok; Ahuja, Rajeev; Safvan, C.P.; Kumar, Sugam

    2011-01-01

    As part of the accelerator augmentation program at IUAC, a high current injector (HCI) is being developed to inject highly charged ions into the superconducting LINAC. The HCI consists of a superconducting (High T c ) ECR source operated on a high voltage deck, producing the high currents of highly charged ions. The ion beams produced by the ECR (PKDELIS) source will be injected into a Radio Frequency Quadrupole accelerator (RFQ) and be accelerated to 180 keV/u. RF power of about 100 kW at 48.5 MHz will be fed to the RFQ during it's actual working. Most of the power fed is dissipated in the system as heat. So a continuous removal of this heat is necessary to maintain tuning parameters and normal running of the RFQ. The IUAC RFQ is a four rod cavity structure consisting of individual, demountable vanes on vane posts. All the components are made of copper except the high vacuum chamber. High vacuum chamber is made of stainless steel and electroplated with 100 microns copper on the inner surface. To take out the heat from the system cooling holes for water circulation are provided in the design of the vanes and vane posts, which together form cooling circuits. There are fourteen vanes in three different lengths and these are mounted on five vane posts. Water enters and exits from the vane posts base. From each post it enters into two or three circuits in parallel and exits into the next vane post and the flow combines again. In effect five cooling circuits are further divided into fourteen circuits. Thermal design of the system is analyzed and optimized using a computational fluid dynamics (CFD) software. The CFD software simultaneously solves the equations of mass, momentum and energy with the given structure, material, fluid and applied boundary conditions. An actual 3-dimensional model of the assembly was made using Solidworks modelling software. To save on simulation time, small holes and minor components were suppressed during analysis. The software used for

  9. Modeling and Simulation for an 8 kW Three-Phase Grid-Connected Photo-Voltaic Power System

    Science.gov (United States)

    Cen, Zhaohui

    2017-09-01

    Gird-connected Photo-Voltaic (PV) systems rated as 5-10 kW level have advantages of scalability and energy-saving, so they are very typical for small-scale household solar applications. In this paper, an 8 kW three-phase grid-connected PV system model is proposed and studied. In this high-fidelity model, some basic PV system components such as solar panels, DC-DC converters, DC-AC inverters and three-phase utility grids are mathematically modelled and organized as a complete simulation model. Also, an overall power controller with Maximum Power Point Control (MPPT) is proposed to achieve both high-efficiency for solar energy harvesting and grid-connection stability. Finally, simulation results demonstrate the effectiveness of the PV system model and the proposed controller, and power quality issues are discussed.

  10. Modeling and Simulation for an 8 kW Three-Phase Grid-Connected Photo-Voltaic Power System

    Directory of Open Access Journals (Sweden)

    Cen Zhaohui

    2017-09-01

    Full Text Available Gird-connected Photo-Voltaic (PV systems rated as 5-10 kW level have advantages of scalability and energy-saving, so they are very typical for small-scale household solar applications. In this paper, an 8 kW three-phase grid-connected PV system model is proposed and studied. In this high-fidelity model, some basic PV system components such as solar panels, DC-DC converters, DC-AC inverters and three-phase utility grids are mathematically modelled and organized as a complete simulation model. Also, an overall power controller with Maximum Power Point Control (MPPT is proposed to achieve both high-efficiency for solar energy harvesting and grid-connection stability. Finally, simulation results demonstrate the effectiveness of the PV system model and the proposed controller, and power quality issues are discussed.

  11. Power sources involving ~ 300W PEMFC fuel cell stacks cooled by different media

    Directory of Open Access Journals (Sweden)

    Dudek Magdalena

    2017-01-01

    Full Text Available Two constructions of ~300W PEMFC stacks, cooled by different media, were analysed. An open-cathode ~300W PEMFC stack cooled by air (Horizon, Singapore and a PEMFC F-42 stack cooled by a liquid medium (Schunk, Germany were chosen for all of the investigations described in this paper. The potential for the design and construction of power sources involving fuel cells, as well as of a hybrid system (fuel cell-lithium battery for mobile and stationary applications, is presented and discussed. The impact of certain experimental parameters on PEMFC stack performance is analysed and discussed.

  12. Charakterystyka etiologiczna udarów mózgu leczonych w Klinice Neurologii UM w Białymstoku z analizą czynników ryzyka

    Directory of Open Access Journals (Sweden)

    Anna Syta-Krzyżanowska

    2010-03-01

    Full Text Available Wstęp: W przeprowadzonych w Polsce badaniach epidemiologicznych stwierdzono utrzymujący się od kilkunastu lat wysoki współczynnik zapadalności na pierwszy w życiu udar mózgu, wzrastający wykładniczo z wiekiem oraz połączony z wciąż dużą śmiertelnością. Poznanie czynników ryzyka oraz wprowadzenie profilaktyki może istotnie zmniejszyć powyższe wskaźniki. Celem pracy było przeprowadzenie analizy epidemiologicznej pacjentów z udarem mózgu hospitalizowanych na Pododdziale Udarowym Kliniki Neurologii USK w Białymstoku. Uwzględniono w szczególności etiologię z czynnikami ryzyka oraz śmiertelnością w zależności od wieku i płci chorych. Materiał i metody: Rozpatrzono wszystkie przypadki pacjentów hospitalizowanych w Klinice Neurologii USK w Białymstoku z powodu udaru mózgu w ciągu pełnego roku kalendarzowego. Posłużono się ankietami prowadzonymi w ramach Narodowego Programu Profilaktyki i Leczenia Chorób Sercowo-Naczyniowych (POLKARD. Obliczenia statystyczne wykonywano przy użyciu programu Statistica w wersji 8.0. Wyniki: Przeanalizowano wyniki 408 pacjentów, w tym 185 (45,3% kobiet oraz 223 (54,7% mężczyzn z rozpoznanym: krwotokiem podpajęczynówkowym – 6,9%, krwotokiem śródmózgowym – 12,5% oraz udarem niedokrwiennym – 80,6%. Etiologię zatorową pochodzenia sercowego zdiagnozowano u 39,4%, zakrzep dużych naczyń u 35%, natomiast udar zatokowy u 11,6% pacjentów. Najczęstszym czynnikiem ryzyka udaru niedokrwiennego mózgu było nadciśnienie tętnicze (81,2%, następnie migotanie przedsionków i choroba niedokrwienna serca (38%. Zmarło 11,6% chorych z udarem niedokrwiennym mózgu oraz 21,5% z udarem krwotocznym. Średnia śmiertelność wyniosła 13,5%. Wnioski: Najczęstszym czynnikiem ryzyka udaru mózgu było nadciśnienie tętnicze, które szczególnie często współwystępowało z dodatkowym czynnikiem ryzyka udaru niedokrwiennego mózgu. Prowadzenie leczenia udaru mózgu w pododdzia

  13. The 25 kW resonant dc/dc power converter

    Science.gov (United States)

    Robson, R. R.

    1983-01-01

    The feasibility of processing 25-kW of power with a single, transistorized, series resonant converter stage was demonstrated by the successful design, development, fabrication, and testing of such a device which employs four Westinghouse D7ST transistors in a full-bridge configuration and operates from a 250-to-350 Vdc input bus. The unit has an overall worst-case efficiency of 93.5% at its full rated output of 1000 V and 25 A dc. A solid-state dc input circuit breaker and output-transient-current limiters are included in and integrated into the design. Full circuit details of the converter are presented along with the test data.

  14. Experimental RA reactor operation with 80% enriched fuel - Program of experimental operation: a) Program of experimental operation with 80% enriched fuel at low power, b) contents of the experimental operation with 80% enriched fuel at higher power levels; Program probnog rada: a) Program probnog rada reaktora sa 80% obogacenim gorivom na malim snagama, b) sadrzaj programa probnog rada reaktora RA sa 80% obogacenim gorivom na vecim snagama

    Energy Technology Data Exchange (ETDEWEB)

    Martinc, R; Sotic, O; Skoric, M; Cupac, S; Bulovic, V; Maric, I; Marinkov, L [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)

    1980-10-15

    Highly enriched (80%) uranium oxide fuel was regularly used in the mixed reactor core with the 2% enriched fuel since 1976. The most important changes related to reactor operation, in comparison with the original design project were related to reactor core fuelling schemes. At the end of 1979 reactor was shutdown due to the corrosion coating noticed on some fuel elements and due to decrease quality of the heavy water. Subsequently the Sanitary inspector of Serbia has prohibited further reactor operation. Restart of the reactor will not be a simple continuation of operation. It is indispensable to perform complete experimental program including measurements of critical parameters at different power levels for the core with fresh 80% enriched fuel. The aim of this document is to obtain working permission and its contents are in agreement with the procedure demanded by the Safety Committee of the Institute. It includes results of optimization and safety analysis for the initial reactor core. Since the permission for restart is not obtained, a separate RA reactor safety report is prepared in addition to the program for experimental operation. This report includes: detailed program for reactor experimental operation with 80% enriched fuel in the core at low power levels, and contents of the experimental operation with 80% enriched fuel in the core at higher power levels. [Serbo-Croat] Od decembra 1976. godine redovno je korisceno 80% obogaceno gorivo u mesanoj resetki reaktorskog jezgra sa 2% obogacenim gorivom. Najvece izmene na reaktoru u odnosu na originalni projekat izvrsene su u nacinu rukovanja gorivom. Krajem marta 1979. godine obustavljen je rad reaktora usled naslaga na gorivnim elementima i loseg stanja teske vode. Naknadno je izdata zabrana za rad reaktora od strane Sanitarnog inspektora SR Srbije. Ponovno pustanje reaktora u rad nece biti jednostavan nastavak rada. Neophodno je da se izvede kompletan program merenja kriticnih parametara i drugih

  15. X-ray diffraction study of KTP (KTiOPO4) crystals under a static electric field

    International Nuclear Information System (INIS)

    Sebastian, M.T.; Klapper, H.; Bolt, R.J.

    1992-01-01

    X-ray diffraction studies are made on ion-conducting potassium titanyl phosphate (KTP) crystals with in situ DC electric field along different crystallographic directions. The X-ray rocking curves recorded with an electric field along the polar b axis (which is the direction of ion conduction) show a strong enhancement of the 040 reflection intensity (reflecting planes normal to the b axis) whereas the h0l reflections (reflecting planes parallel to the polar axis) do not show any intensity change. For an electric field normal to the polar axis no intensity change, either in 040 or in h0l reflections occurs. This observation is supplemented by X-ray topography. The 040 X-ray topographs recorded with in situ electric field along b exhibit strong extinction contrast in the form of striations parallel to the polar (ion-conduction) axis. The 040 intensity increase and the striation contrast are attributed to lattice deformation by the space-charge polarization due to the movement of the K + ions under the influence of the electric field. (orig.)

  16. High Power (50W) WDM Space Lasercom 1.5um Fiber Laser Transmitter, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Fibertek proposes to develop and demonstrate a spaceflight prototype of a wideband, high power (up to 50W), polarization maintaining (PM), 1.5-um fiber laser...

  17. POWERED LED LIGHTING SUPPLIED FROM PV CELLS

    Directory of Open Access Journals (Sweden)

    Tirshu M.

    2011-12-01

    Full Text Available The paper deals with practical realization of efficient lighting system based on LED’s of 80W total power mounted on corridor ceiling total length of which is 120m and substitutes existing traditional lighting system consisting of 29 lighting blocks with 4 fluorescent lamps each of them and summary power 2088W. Realized lighting system is supplied from two photovoltaic panels of power 170W. Generated energy by PV cells is accumulated in two accumulators of 75Ah capacity and from battery by means of specialized convertor is applied to lighting system. Additionally, paper present data measured by digital weather station (solar radiation and UV index, which is mounted near of PV cells and comparative analyze of solar energy with real energy generated by PV cells is done. Measured parameters by digital weather station are stored by computer in on-line mode.

  18. An actively mode-locked Ho: YAG solid laser pumped by a Tm: YLF laser

    International Nuclear Information System (INIS)

    Yao, B Q; Cui, Z; Wang, J; Duan, X M; Dai, T Y; Du, Y Q; Yuan, J H; Liu, W

    2015-01-01

    A continuous wave mode-locked (CWML) Ho: YAG laser based on an acousto-optic modulator (AOM) pumped by a 1.9 μm Tm: YLF laser is demonstrated. This is the first time a report on an active CWML Ho: YAG laser has been published. A maximum output power of 1.04 W at 2097.25 nm in the CWML regime is obtained at a pump power of 13.2 W, corresponding to a slope efficiency of 13.3%. The mode-locked pulse repetition frequency is 82.76 MHz and the single pulse energy is 12.57 nJ. The mode-locked pulse width is 102 ps measured through a no-background second harmonic autocorrelation with KTP as the nonlinear crystal. Furthermore, the M 2 factor is calculated to be 1.146. (letter)

  19. Complete indium-free CW 200W passively cooled high power diode laser array using double-side cooling technology

    Science.gov (United States)

    Wang, Jingwei; Zhu, Pengfei; Liu, Hui; Liang, Xuejie; Wu, Dihai; Liu, Yalong; Yu, Dongshan; Zah, Chung-en; Liu, Xingsheng

    2017-02-01

    High power diode lasers have been widely used in many fields. To meet the requirements of high power and high reliability, passively cooled single bar CS-packaged diode lasers must be robust to withstand thermal fatigue and operate long lifetime. In this work, a novel complete indium-free double-side cooling technology has been applied to package passively cooled high power diode lasers. Thermal behavior of hard solder CS-package diode lasers with different packaging structures was simulated and analyzed. Based on these results, the device structure and packaging process of double-side cooled CS-packaged diode lasers were optimized. A series of CW 200W 940nm high power diode lasers were developed and fabricated using hard solder bonding technology. The performance of the CW 200W 940nm high power diode lasers, such as output power, spectrum, thermal resistance, near field, far field, smile, lifetime, etc., is characterized and analyzed.

  20. Eye safe high power laser diode in the 1410-1550nm range

    Science.gov (United States)

    Boucart, Julien; de Largy, Brian; Kearley, Mark; Lichtenstein, Norbert

    2010-02-01

    The demand for high power lasers emitting in the 14xx-15xxnm range is growing for applications in fields such as medical or homeland security. We demonstrate high power laser diodes with emission at 1430, 1470 and 1560 nm. Single multimode emitters at 1470nm emit about 3.5W in CW operation. Power conversion efficiency can reach values as high as 38.5%. With this base material, single and multi-emitter fiber coupled modules are built. Additionally, bars on passive and microchannel coolers are fabricated that deliver 25W and 38W respectively in CW mode, while obtaining more than 80 W in pulsed mode. All reliability tests show an outstanding stability of the material with no signs of wearout after 3750 hrs under strong acceleration conditions.

  1. Over 8 W high peak power UV laser with a high power Q-switched Nd:YVO4 oscillator and the compact extra-cavity sum-frequency mixing

    International Nuclear Information System (INIS)

    Yan, X P; Liu, Q; Gong, M; Wang, D S; Fu, X

    2009-01-01

    A 8.2 W UV laser was reported with the compact extra-cavity sum-frequency mixing. The IR fundamental frequency source was a high power and high beam quality Q-switched Nd:YVO 4 oscillator. 38 W fundamental frequency laser at 1064 nm was obtained at the pulse repetition rate of 450 kHz with the beam quality factors of M 2 x = 1.27, M 2 y = 1.21. The type I and type II phase-matched LBO crystals were used as the extra-cavity frequency doubling and mixing crystals respectively. At 38 kHz, 8.2 W UV laser at 355 nm was achieved with the pulse duration of 8 ns corresponding to the pulse peak power as high as 27 kW, and the optical-optical conversion efficiency from IR to UV was 25.6%. The output characteristics of the IR and the harmonic generations varying with the pulse repetition rate were also investigated detailedly

  2. Mathematical investigation of the possibility of a power increase of the subcritical assembly in Dubna (SAD) up to 100 kW

    International Nuclear Information System (INIS)

    Petrochenkov, S.A.; Shvetsov, V.N.; Polanski, A.

    2007-01-01

    We present the results of Monte-Carlo modeling of the experimental accelerator-driven electronuclear system composed of the subcritical assembly and DLNP JINR Phasotron. The expected thermal power of the subcritical assembly in Dubna (SAD) is about 30 kW. The possibility of assembly power increase without changes in design and basic elements is considered. The proposed assembly upgrade gives power increase up to 100 kW. It is of importance that proposed upgrade operations can be performed both before and after the run with nominal power and partial fulfillment of a basic experimental program

  3. 915 MHz microwave ablation with high output power in in vivo porcine spleens

    International Nuclear Information System (INIS)

    Gao Yongyan; Wang Yang; Duan Yaqi; Li Chunling; Sun Yuanyuan; Zhang Dakun; Lu Tong; Liang Ping

    2010-01-01

    Objective: The purpose of this study was to evaluate the efficacy of 915 MHz microwave (MW) ablation with high output power in in vivo porcine spleens. Materials and methods: MW ablations were performed in 9 porcine spleens with an internally cooled 915 MHz antenna. Thermocouples were placed at 5, 10, 15, 20 mm away from the antenna to measure temperatures in real-time during MW emission. The energy was applied for 10 min at high output power of 60 W, 70 W or 80 W. Gross specimens were sectioned and measured to determine ablation size. Representative areas were examined by light microscopy and electron microscopy. Coagulation sizes and temperatures were compared among the three power groups. Results: Hematoxylin-eosin staining showed irreversible necrosis in the splenic coagulation area after MW ablation. As the power was increased, long-axis diameter enlarged significantly (p .05). The coagulation size of long-axis and short-axis diameter with 80 W in vivo spleen ablation was 6.43 ± 0.52 and 4.95 ± 0.30 cm, respectively. With the increase of output power, maximum temperatures at 5, 10, 15, 20 mm from the antenna were increased accordingly (p o C respectively. Conclusion: With internally cooled antenna and high output power, 915 MHz MW ablation in the spleen could produce irreversible tissue necrosis of clinical significance. MW ablation may be used as a promising minimally invasive method for the treatment of splenic diseases.

  4. Alkaline polymer electrolyte fuel cells stably working at 80 °C

    Science.gov (United States)

    Peng, Hanqing; Li, Qihao; Hu, Meixue; Xiao, Li; Lu, Juntao; Zhuang, Lin

    2018-06-01

    Alkaline polymer electrolyte fuel cells are a new class of polymer electrolyte fuel cells that fundamentally enables the use of nonprecious metal catalysts. The cell performance mostly relies on the quality of alkaline polymer electrolytes, including the ionic conductivity and the chemical/mechanical stability. For a long time, alkaline polymer electrolytes are thought to be too weak in stability to allow the fuel cell to be operated at elevated temperatures, e.g., above 60 °C. In the present work, we report a progress in the state-of-the-art alkaline polymer electrolyte fuel cell technology. By using a newly developed alkaline polymer electrolyte, quaternary ammonia poly (N-methyl-piperidine-co-p-terphenyl), which simultaneously possesses high ionic conductivity and excellent chemical/mechanical stability, the fuel cell can now be stably operated at 80 °C with high power density. The peak power density reaches ca. 1.5 W/cm2 at 80 °C with Pt/C catalysts used in both the anode and the cathode. The cell works stably in a period of study over 100 h.

  5. High-power terahertz optical pulse generation with a dual-wavelength harmonically mode-locked Yb:YAG laser

    International Nuclear Information System (INIS)

    Zhuang, W Z; Chang, M T; Su, K W; Huang, K F; Chen, Y F

    2013-01-01

    We report on high-power terahertz optical pulse generation with a dual-wavelength harmonically mode-locked Yb:YAG laser. A semiconductor saturable absorber mirror is developed to achieve synchronously mode-locked operation at two spectral bands centered at 1031.67 and 1049.42 nm with a pulse duration of 1.54 ps and a pulse repetition rate of 80.3 GHz. With a diamond heat spreader to improve the heat removal efficiency, the average output power can be up to 1.1 W at an absorbed pump power of 5.18 W. The autocorrelation traces reveal that the mode-locked pulse is modulated with a beat frequency of 4.92 THz and displays a modulation depth to be greater than 80%. (paper)

  6. Conceptual design of the cryogenic system and estimation of the recirculated power for CFETR

    Science.gov (United States)

    Liu, Xiaogang; Qiu, Lilong; Li, Junjun; Wang, Zhaoliang; Ren, Yong; Wang, Xianwei; Li, Guoqiang; Gao, Xiang; Bi, Yanfang

    2017-01-01

    The China Fusion Engineering Test Reactor (CFETR) is the next tokamak in China’s roadmap for realizing commercial fusion energy. The CFETR cryogenic system is crucial to creating and maintaining operational conditions for its superconducting magnet system and thermal shields. The preliminary conceptual design of the CFETR cryogenic system has been carried out with reference to that of ITER. It will provide an average capacity of 75 to 80 kW at 4.5 K and a peak capacity of 1300 kW at 80 K. The electric power consumption of the cryogenic system is estimated to be 24 MW, and the gross building area is about 7000 m2. The relationships among the auxiliary power consumed by the cryogenic system, the fusion power gain and the recirculated power of CFETR are discussed, with the suggestion that about 52% of the electric power produced by CFETR in phase II must be recirculated to run the fusion test reactor.

  7. Power train analysis for the DOE/NASA 100-kW wind turbine generator

    Science.gov (United States)

    Seidel, R. C.; Gold, H.; Wenzel, L. M.

    1978-01-01

    Progress in explaining variations of power experienced in the on-line operation of a 100 kW experimental wind turbine-generator is reported. Data are presented that show the oscillations tend to be characteristic of a wind-driven synchronous generator because of low torsional damping in the power train, resonances of its large structure, and excitation by unsteady and nonuniform wind flow. The report includes dynamic analysis of the drive-train torsion, the generator, passive driveline damping, and active pitch control as well as correlation with experimental recordings. The analysis assumes one machine on an infinite bus with constant generator-field excitation.

  8. Analysis of RF section of 250 kW CW C-Band high power klystron

    International Nuclear Information System (INIS)

    Badola, Richa; Kaushik, Meenu; Baloda, Suman; Kirti; Vrati; Lamba, O.S.; Joshi, L.M.

    2012-01-01

    Klystron is a microwave tube which is used as a power amplifier in various applications like radar, particle accelerators and thermonuclear reactors. The paper deals with the analysis of RF section of 250 kW CW C band high power klystron for 50 to 60 kV beam voltage The simulation is done using Poisson's superfish and AJ disk software's Design of cavity is done using superfish. The result of superfish is used to decide the dimensions of the geometry of the cavity and AJ disk is used to determined the centre to centre distances between the cavities in order to obtain the desired powers. (author)

  9. Economics of superconductive energy storage inductor-converter units in power systems

    International Nuclear Information System (INIS)

    Yadavalli, S.R.

    1975-01-01

    Since the original proposal by Boom and Peterson in 1972, there has been growing interest in superconductive energy storage inductor converter units (IC units) for use in large power systems for peak shaving and load leveling. Different aspects of it are being studied at the University of Wisconsin and elsewhere. An economic study of such IC units shows that large IC units, bigger than about 1000 MWh, are economically competitive with other peaking alternatives, larger units being more economical. External electrical circuit losses in IC units have negligible effect on their storage and power capacities. There are three credits which could be of significant economic value to IC units. These are: (1) transmission credit which varied from about $4 to $60/kW peak power, with a typical value of about $35/kW; (2) pollution credit which varied from about $5 to $160/kW with a typical value of $80/kW; and Spinning Reserve Credit which varied from about $20 to $370/kW with a typical value of $90/kW

  10. Ten-watt level picosecond parametric mid-IR source broadly tunable in wavelength

    Science.gov (United States)

    Vyvlečka, Michal; Novák, Ondřej; Roškot, Lukáscaron; Smrž, Martin; Mužík, Jiří; Endo, Akira; Mocek, Tomáš

    2018-02-01

    Mid-IR wavelength range (between 2 and 8 μm) offers perspective applications, such as minimally-invasive neurosurgery, gas sensing, or plastic and polymer processing. Maturity of high average power near-IR lasers is beneficial for powerful mid-IR generation by optical parametric conversion. We utilize in-house developed Yb:YAG thin-disk laser of 100 W average power at 77 kHz repetition rate, wavelength of 1030 nm, and about 2 ps pulse width for pumping of a ten-watt level picosecond mid-IR source. Seed beam is obtained by optical parametric generation in a double-pass 10 mm long PPLN crystal pumped by a part of the fundamental near-IR beam. Tunability of the signal wavelength between 1.46 μm and 1.95 μm was achieved with power of several tens of miliwatts. Main part of the fundamental beam pumps an optical parametric amplification stage, which includes a walk-off compensating pair of 10 mm long KTP crystals. We already demonstrated the OPA output signal and idler beam tunability between 1.70-1.95 μm and 2.18-2.62 μm, respectively. The signal and idler beams were amplified up to 8.5 W and 5 W, respectively, at 42 W pump without evidence of strong saturation. Thus, increase in signal and idler output power is expected for pump power increase.

  11. High power all-solid-state fourth harmonic generation of 266 nm at the pulse repetition rate of 100 kHz

    International Nuclear Information System (INIS)

    Liu, Q; Yan, X P; Fu, X; Gong, M; Wang, D S

    2009-01-01

    14.8 W UV laser at 266 nm was reported with the extra cavity frequency quartered configuration. The fundamental frequency IR source is a high-power high-beam-quality acoustic-optic Q-switched Nd:YVO 4 master-oscillator-power-amplifier laser. The type-I phase-matched LBO and type-I phase-matched BBO crystals were used as the extra-cavity frequency doubled and quartered crystal respectively. 14.8 W UV laser of 266 nm was obtained at the pulse repetition rate of 100 kHz with the conversion efficiency of 18.3% from green to UV, and the pulse duration of the UV laser was 10 ns corresponding to the pulse peak power of 14.8 kW. At 150 kHz, 11.5 W power output was obtained. The highest peak power of 21 kW was also achieved at 80 kHz with the average output power of 14.5 W

  12. Quasi-continuous wave and continuous wave laser operation of Eu:KGd(WO4)2 crystal on a 5D0 → 7F4 transition

    International Nuclear Information System (INIS)

    Dashkevich, V I; Orlovich, V A; Bui, A A; Bagayev, S N; Vatnik, S M; Loiko, P A; Yumashev, K V; Kuleshov, N V; Pavlyuk, A A

    2015-01-01

    We report on the first demonstration of quasi-continuous wave (quasi-CW) and real CW room-temperature lasing on the 5 D 0  →  7 F 4 transition of Eu 3+ -doped material using a 25 at.%Eu 3+  : KGd(WO 4 ) 2 crystal pumped into the 7 F 1  →  5 D 1 transition by a diode-end-pumped Nd 3+  : KGd(WO 4 ) 2 /KTP green laser at 533.6 nm. The maximum CW output power of this laser at 702.3 nm is 5.3 mW with 1.4% green-to-red conversion efficiency. In quasi-CW operation mode with a 10% duty cycle, the peak power of ms long pulses reaches ∼54 mW, which corresponds to the optical conversion efficiency of 3.5%. (letter)

  13. First Results of the IOT Based 300 kW 500 MHz Amplifier for the Diamond Light Source

    CERN Document Server

    Jensen, Morten; Maddock, Matt; Müller, Marc; Rains, Simon; Watkins, Alun V

    2005-01-01

    We present the first RF measurements of the IOT based 300 kW 500 MHz amplifier for the Diamond Light Source. Four 80 kW IOTs are combined using a waveguide combiner to achieve the RF requirement of up to 300 kW for each of three superconducting cavities for the main storage ring. The IOTs are protected by a full power circulator and a 300 kW ferrite RF load. This is the first time IOTs will be used for a synchrotron light source. This paper gives an overview of the design of the Thales amplifiers and IOTs with commissioning results including measurements of key components and overall RF performance following factory tests and the installation of the first unit

  14. Crustal structure of the Churchill-Superior boundary zone between 80 and 98 deg W longitude from Magsat anomaly maps and stacked passes

    Science.gov (United States)

    Hall, D. H.; Millar, T. W.; Noble, I. A.

    1985-01-01

    A modeling technique using spherical shell elements and equivalent dipole sources has been applied to Magsat signatures at the Churchill-Superior boundary in Manitoba, Ontario, and Ungava. A large satellite magnetic anomaly (12 nT amplitude) on POGO and Magsat maps near the Churchill-Superior boundary was found to be related to the Richmond Gulf aulacogen. The averaged crustal magnetization in the source region is 5.2 A/m. Stacking of the magnetic traces from Magsat passes reveals a magnetic signature (10 nT amplitude) at the Churchill-Superior boundary in an area studied between 80 deg W and 98 deg W. Modeling suggests a steplike thickening of the crust on the Churchill side of the boundary in a layer with a magnetization of 5 A/m. Signatures on aeromagnetic maps are also found in the source areas for both of these satellite anomalies.

  15. Measurement of the w boson mass and $w^{+} w^{-}$ production and decay properties in $e^{+}e^{-}$ collisions at s**(1/2) = 172-GeV

    CERN Document Server

    Ackerstaff, K.; Allison, John; Altekamp, N.; Anderson, K.J.; Anderson, S.; Arcelli, S.; Asai, S.; Axen, D.; Azuelos, G.; Ball, A.H.; Barberio, E.; Barlow, Roger J.; Bartoldus, R.; Batley, J.R.; Baumann, S.; Bechtluft, J.; Beeston, C.; Behnke, T.; Bell, A.N.; Bell, Kenneth Watson; Bella, G.; Bentvelsen, S.; Bethke, S.; Biebel, O.; Biguzzi, A.; Bird, S.D.; Blobel, V.; Bloodworth, I.J.; Bloomer, J.E.; Bobinski, M.; Bock, P.; Bonacorsi, D.; Boutemeur, M.; Bouwens, B.T.; Braibant, S.; Brigliadori, L.; Brown, Robert M.; Burckhart, H.J.; Burgard, C.; Burgin, R.; Capiluppi, P.; Carnegie, R.K.; Carter, A.A.; Carter, J.R.; Chang, C.Y.; Charlton, David G.; Chrisman, D.; Clarke, P.E.L.; Cohen, I.; Conboy, J.E.; Cooke, O.C.; Cuffiani, M.; Dado, S.; Dallapiccola, C.; Dallavalle, G.Marco; Davies, R.; De Jong, S.; del Pozo, L.A.; Desch, K.; Dienes, B.; Dixit, M.S.; do Couto e Silva, E.; Doucet, M.; Duchovni, E.; Duckeck, G.; Duerdoth, I.P.; Eatough, D.; Edwards, J.E.G.; Estabrooks, P.G.; Evans, H.G.; Evans, M.; Fabbri, F.; Fanti, M.; Faust, A.A.; Fiedler, F.; Fierro, M.; Fischer, H.M.; Fleck, I.; Folman, R.; Fong, D.G.; Foucher, M.; Furtjes, A.; Futyan, D.I.; Gagnon, P.; Gary, J.W.; Gascon, J.; Gascon-Shotkin, S.M.; Geddes, N.I.; Geich-Gimbel, C.; Geralis, T.; Giacomelli, G.; Giacomelli, P.; Giacomelli, R.; Gibson, V.; Gibson, W.R.; Gingrich, D.M.; Glenzinski, D.; Goldberg, J.; Goodrick, M.J.; Gorn, W.; Grandi, C.; Gross, E.; Grunhaus, J.; Gruwe, M.; Hajdu, C.; Hanson, G.G.; Hansroul, M.; Hapke, M.; Hargrove, C.K.; Hart, P.A.; Hartmann, C.; Hauschild, M.; Hawkes, C.M.; Hawkings, R.; Hemingway, R.J.; Herndon, M.; Herten, G.; Heuer, R.D.; Hildreth, M.D.; Hill, J.C.; Hillier, S.J.; Hobson, P.R.; Homer, R.J.; Honma, A.K.; Horvath, D.; Hossain, K.R.; Howard, R.; Huntemeyer, P.; Hutchcroft, D.E.; Igo-Kemenes, P.; Imrie, D.C.; Ingram, M.R.; Ishii, K.; Jawahery, A.; Jeffreys, P.W.; Jeremie, H.; Jimack, M.; Joly, A.; Jones, C.R.; Jones, G.; Jones, M.; Jost, U.; Jovanovic, P.; Junk, T.R.; Karlen, D.; Kartvelishvili, V.; Kawagoe, K.; Kawamoto, T.; Kayal, P.I.; Keeler, R.K.; Kellogg, R.G.; Kennedy, B.W.; Kirk, J.; Klier, A.; Kluth, S.; Kobayashi, T.; Kobel, M.; Koetke, D.S.; Kokott, T.P.; Kolrep, M.; Komamiya, S.; Kress, T.; Krieger, P.; von Krogh, J.; Kyberd, P.; Lafferty, G.D.; Lahmann, R.; Lai, W.P.; Lanske, D.; Lauber, J.; Lautenschlager, S.R.; Layter, J.G.; Lazic, D.; Lee, A.M.; Lefebvre, E.; Lellouch, D.; Letts, J.; Levinson, L.; Lloyd, S.L.; Loebinger, F.K.; Long, G.D.; Losty, M.J.; Ludwig, J.; Macchiolo, A.; Macpherson, A.; Mannelli, M.; Marcellini, S.; Markus, C.; Martin, A.J.; Martin, J.P.; Martinez, G.; Mashimo, T.; Mattig, Peter; McDonald, W.John; McKenna, J.; Mckigney, E.A.; McMahon, T.J.; McPherson, R.A.; Meijers, F.; Menke, S.; Merritt, F.S.; Mes, H.; Meyer, J.; Michelini, A.; Mikenberg, G.; Miller, D.J.; Mincer, A.; Mir, R.; Mohr, W.; Montanari, A.; Mori, T.; Morii, M.; Muller, U.; Mihara, S.; Nagai, K.; Nakamura, I.; Neal, H.A.; Nellen, B.; Nisius, R.; O'Neale, S.W.; Oakham, F.G.; Odorici, F.; Ogren, H.O.; Oh, A.; Oldershaw, N.J.; Oreglia, M.J.; Orito, S.; Palinkas, J.; Pasztor, G.; Pater, J.R.; Patrick, G.N.; Patt, J.; Pearce, M.J.; Perez-Ochoa, R.; Petzold, S.; Pfeifenschneider, P.; Pilcher, J.E.; Pinfold, J.; Plane, David E.; Poffenberger, P.; Poli, B.; Posthaus, A.; Rees, D.L.; Rigby, D.; Robertson, S.; Robins, S.A.; Rodning, N.; Roney, J.M.; Rooke, A.; Ros, E.; Rossi, A.M.; Routenburg, P.; Rozen, Y.; Runge, K.; Runolfsson, O.; Ruppel, U.; Rust, D.R.; Rylko, R.; Sachs, K.; Saeki, T.; Sarkisian, E.K.G.; Sbarra, C.; Schaile, A.D.; Schaile, O.; Scharf, F.; Scharff-Hansen, P.; Schenk, P.; Schieck, J.; Schleper, P.; Schmitt, B.; Schmitt, S.; Schoning, A.; Schroder, Matthias; Schultz-Coulon, H.C.; Schumacher, M.; Schwick, C.; Scott, W.G.; Shears, T.G.; Shen, B.C.; Shepherd-Themistocleous, C.H.; Sherwood, P.; Siroli, G.P.; Sittler, A.; Skillman, A.; Skuja, A.; Smith, A.M.; Snow, G.A.; Sobie, R.; Soldner-Rembold, S.; Springer, Robert Wayne; Sproston, M.; Stephens, K.; Steuerer, J.; Stockhausen, B.; Stoll, K.; Strom, David M.; Szymanski, P.; Tafirout, R.; Talbot, S.D.; Tanaka, S.; Taras, P.; Tarem, S.; Teuscher, R.; Thiergen, M.; Thomson, M.A.; von Torne, E.; Towers, S.; Trigger, I.; Trocsanyi, Z.; Tsur, E.; Turcot, A.S.; Turner-Watson, M.F.; Utzat, P.; Van Kooten, Rick J.; Verzocchi, M.; Vikas, P.; Vokurka, E.H.; Voss, H.; Wackerle, F.; Wagner, A.; Ward, C.P.; Ward, D.R.; Watkins, P.M.; Watson, A.T.; Watson, N.K.; Wells, P.S.; Wermes, N.; White, J.S.; Wilkens, B.; Wilson, G.W.; Wilson, J.A.; Wolf, G.; Wyatt, T.R.; Yamashita, S.; Yekutieli, G.; Zacek, V.; Zer-Zion, D.

    1998-01-01

    This paper describes the measurement of the W boson mass, M_W, and decay width, Gamma_W, from the direct reconstruction of the invariant mass of its decay products in W pair events collected at a mean centre-of-mass energy of sqrt{s} = 172.12 GeV with the OPAL detector at LEP. Measurements of the W pair production cross-section, the W decay branching fractions and properties of the W decay final states are also described. A total of 120 candidate W^+W^- events has been selected for an integrated luminosity of 10.36 pb^-1. The W^+W^- production cross-section is measured to be sigma_WW = 12.3 +/- 1.3(stat.) +/- 0.3(syst.) pb, consistent with the Standard Model expectation. The W^+W^- -> qq(bar) l nu and W^+W^- -> qq(bar)qq(bar) final states are used to obtain a direct measurement of Gamma_W = 1.30^{+0.62}_{-0.55}(stat.) +/- 0.18(syst.) GeV. Assuming the Standard Model relation between M_W and Gamma_W, the W boson mass is measured to be M_W = 80.32 +/- 0.30(stat.) +/- 0.09(syst.) GeV. The event properties of the...

  16. MegaFlex Scale-Up Cost & Risk Reduction for >50kW Future Power Demands, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — As the MegaFlex solar array is scaled for power demands greater than 50kW over the next 20 years and deployed load requirements remain high or increase, advanced...

  17. An extended conventional fuel cycle for the B and W mPower{sup TM} small modular nuclear reactor

    Energy Technology Data Exchange (ETDEWEB)

    Scarangella, M. J. [Babcock and Wilcox Company, 109 Ramsey Place, Lynchburg, VA 24502 (United States)

    2012-07-01

    The B and W mPower{sup TM} reactor is a small pressurized water reactor (PWR) with an integral once-through steam generator and a thermal output of about 500 MW; it is intended to replace aging fossil power plants of similar output. The core is composed of 69 reduced-height PWR assemblies with the familiar 17 x 17 fuel rod array. The Babcock and Wilcox Company (B and W) is offering a core loading and cycle management plan for a four-year cycle based on its presumed attractiveness to potential customers. This option is a once-through fuel cycle in which the entire core is discharged and replaced after four years. In addition, a conventional fuel utilization strategy, employing a periodic partial reload and shuffle, was developed as an alternative to the four-year once-through fuel cycle. This study, which was performed using the Studsvik core design code suite, is a typical multi-cycle projection analysis of the type performed by most fuel management organizations such as fuel vendors and utilities. In the industry, the results of such projections are used by the financial arms of these organizations to assist in making long-term decisions. In the case of the B and W mPower reactor, this analysis demonstrates flexibility for customers who consider the once-through fuel cycle unacceptable from a fuel utilization standpoint. As expected, when compared to the once-through concept, reloads of the B and W mPower reactor will achieve higher batch average discharge exposure, will have adequate shut-down margin, and will have a relatively flat hot excess reactivity trend at the expense of slightly increased peaking. (authors)

  18. The propagation of high power CW scanning electron beam in air

    International Nuclear Information System (INIS)

    Korenev, Sergey; Korenev, Ivan

    2002-01-01

    The question of propagation of high power electron beam in air presents the scientific and applied interests. The high power (80 kW) CW electron accelerator 'Rhodotron' with kinetic energy of electrons 5 and 10 MeV was used in the experiments. The experimental results for propagation of scanning electron beams in air are presented and discussed

  19. Effects of saddle height on economy and anaerobic power in well-trained cyclists.

    Science.gov (United States)

    Peveler, Willard W; Green, James M

    2011-03-01

    In cycling, saddle height adjustment is critical for optimal performance and injury prevention. A 25-35° knee angle is recommended for injury prevention, whereas 109% of inseam, measured from floor to ischium, is recommended for optimal performance. Previous research has demonstrated that these 2 methods produce significantly different saddle heights and may influence cycling performance. This study compared performance between these 2 methods for determining saddle height. Subjects consisted of 11 well-trained (VO2max = 61.55 ± 4.72 ml·kg·min) male cyclists. Subjects completed a total of 8 performance trials consisting of a graded maximal protocol, three 15-minute economy trials, and 4 anaerobic power trials. Dependent measures for economy (VO2, heart rate, and rating of perceived exertion) and anaerobic power (peak power and mean power) were compared using repeated measures analysis of variance (α = 0.05). VO2 was significantly lower (reflecting greater economy) at a 25° knee angle (44.77 ± 6.40 ml·kg·min) in comparison to a 35° knee angle (45.22 ± 6.79 ml·kg·min) and 109% of inseam (45.98 ± 5.33 ml·kg·min). Peak power at a 25° knee angle (1,041.55 ± 168.72 W) was significantly higher in relation to 109% of inseam (1,002.05 ± 147.65 W). Mean power at a 25° knee angle (672.37 ± 90.21 W) was significantly higher in relation to a 35° knee angle (654.71 ± 80.67 W). Mean power was significantly higher at 109% of inseam (662.86 ± 79.72 W) in relation to a 35° knee angle (654.71 ± 80.67 W). Use of 109% of inseam fell outside the recommended 25-35° range 73% of the time. Use of 25° knee angle appears to provide optimal performance while keeping knee angle within the recommended range for injury prevention.

  20. Silicon Carbide (SiC) Power Processing Unit (PPU) for Hall Effect Thrusters

    Science.gov (United States)

    Reese, Bradley

    2015-01-01

    Arkansas Power Electronics International (APEI), Inc., is developing a high-efficiency, radiation-hardened 3.8-kW SiC power supply for the PPU of Hall effect thrusters. This project specifically targets the design of a PPU for the high-voltage Hall accelerator (HiVHAC) thruster, with target specifications of 80- to 160-V input, 200- to 700-V/5A output, efficiency greater than 96 percent, and peak power density in excess of 2.5 kW/kg. The PPU under development uses SiC junction field-effect transistor power switches, components that APEI, Inc., has irradiated under total ionizing dose conditions to greater than 3 MRad with little to no change in device performance.

  1. Thermal conductivity from hierarchical heat sinks using carbon nanotubes and graphene nanosheets.

    Science.gov (United States)

    Hsieh, Chien-Te; Lee, Cheng-En; Chen, Yu-Fu; Chang, Jeng-Kuei; Teng, Hsi-sheng

    2015-11-28

    The in-plane (kip) and through-plane (ktp) thermal conductivities of heat sinks using carbon nanotubes (CNTs), graphene nanosheets (GNs), and CNT/GN composites are extracted from two experimental setups within the 323-373 K temperature range. Hierarchical three-dimensional CNT/GN frameworks display higher kip and ktp values, as compared to the CNT- and GN-based heat sinks. The kip and ktp values of the CNT/GN-based heat sink reach as high as 1991 and 76 W m(-1) K(-1) at 323 K, respectively. This improved thermal conductivity is attributed to the fact that the hierarchical heat sink offers a stereo thermal conductive network that combines point, line, and plane contact, leading to better heat transport. Furthermore, the compression treatment provided an efficient route to increase both kip and ktp values. This result reveals that the hierarchical carbon structures become denser, inducing more thermal conductive area and less thermal resistivity, i.e., a reduced possibility of phonon-boundary scattering. The correlation between thermal and electrical conductivity (ε) can be well described by two empirical equations: kip = 567 ln(ε) + 1120 and ktp = 20.6 ln(ε) + 36.1. The experimental results are obtained within the temperature range of 323-373 K, suitably complementing the thermal management of chips for consumer electronics.

  2. Incoherent beam combining of fiber lasers by an all-fiber 7 × 1 signal combiner at a power level of 14 kW.

    Science.gov (United States)

    Lei, Chengmin; Gu, Yanran; Chen, Zilun; Wang, Zengfeng; Zhou, Pu; Ma, Yanxing; Xiao, Hu; Leng, Jinyong; Wang, Xiaolin; Hou, Jing; Xu, Xiaojun; Chen, Jinbao; Liu, Zejin

    2018-04-16

    We demonstrate an all-fiber 7 × 1 signal combiner with an output core diameter of 50 μm for high power incoherent beam combining of seven self-made Yb-doped single-mode fiber lasers around a wavelength of 1080 nm and output power of 2 kW. 14.1 kW combined output power is achieved with a total transmission efficiency of higher than 98.5% and a beam quality of M 2 = 5.37, which is close to the theoretical results based on finite-difference beam propagation technique. To the best of our knowledge, this is the highest output power ever reported for all-fiber structure beam combining generation, which indicates the feasibility and potential of >10 kW high brightness incoherent beam combining based on an all-fiber signal combiner.

  3. 1?10 kW Stationary Combined Heat and Power Systems Status and Technical Potential: Independent Review

    Energy Technology Data Exchange (ETDEWEB)

    Maru, H. C.; Singhal, S. C.; Stone, C.; Wheeler, D.

    2010-11-01

    This independent review examines the status and technical potential of 1-10 kW stationary combined heat and power fuel cell systems and analyzes the achievability of the DOE cost, efficiency, and durability targets for 2012, 2015, and 2020.

  4. Fabrication of an Fe80.5Si7.5B6Nb5Cu Amorphous-Nanocrystalline Powder Core with Outstanding Soft Magnetic Properties

    Science.gov (United States)

    Zhang, Zongyang; Liu, Xiansong; Feng, Shuangjiu; Rehman, Khalid Mehmood Ur

    2018-03-01

    In this study, the melt spinning method was used to develop Fe80.5Si7.5B6Nb5Cu amorphous ribbons in the first step. Then, the Fe80.5Si7.5B6Nb5Cu amorphous-nanocrystalline core with a compact microstructure was obtained by multiple processes. The main properties of the magnetic powder core, such as micromorphology, thermal behavior, permeability, power loss and quality factor, have been analyzed. The obtained results show that an Fe80.5Si7.5B6Nb5Cu amorphous-nanocrystalline duplex core has high permeability (54.8-57), is relatively stable at different frequencies and magnetic fields, and the maximum power loss is only 313 W/kg; furthermore, it has a good quality factor.

  5. Time Trials Versus Time-to-Exhaustion Tests: Effects on Critical Power, W', and Oxygen-Uptake Kinetics.

    Science.gov (United States)

    Karsten, Bettina; Baker, Jonathan; Naclerio, Fernando; Klose, Andreas; Bianco, Antonino; Nimmerichter, Alfred

    2018-02-01

    To investigate single-day time-to-exhaustion (TTE) and time-trial (TT) -based laboratory tests values of critical power (CP), W prime (W'), and respective oxygen-uptake-kinetic responses. Twelve cyclists performed a maximal ramp test followed by 3 TTE and 3 TT efforts interspersed by 60 min recovery between efforts. Oxygen uptake ( V ˙ O 2 ) was measured during all trials. The mean response time was calculated as a description of the overall [Formula: see text]-kinetic response from the onset to 2 min of exercise. TTE-determined CP was 279 ± 52 W, and TT-determined CP was 276 ± 50 W (P = .237). Values of W' were 14.3 ± 3.4 kJ (TTE W') and 16.5 ± 4.2 kJ (TT W') (P = .028). While a high level of agreement (-12 to 17 W) and a low prediction error of 2.7% were established for CP, for W' limits of agreements were markedly lower (-8 to 3.7 kJ), with a prediction error of 18.8%. The mean standard error for TTE CP values was significantly higher than that for TT CP values (2.4% ± 1.9% vs 1.2% ± 0.7% W). The standard errors for TTE W' and TT W' were 11.2% ± 8.1% and 5.6% ± 3.6%, respectively. The [Formula: see text] response was significantly faster during TT (~22 s) than TTE (~28 s). The TT protocol with a 60-min recovery period offers a valid, time-saving, and less error-filled alternative to conventional and more recent testing methods. Results, however, cannot be transferred to W'.

  6. Measurement of the W-pair cross-section and of the W mass in e+ e- interactions at 172 GeV

    Science.gov (United States)

    DELPHI Collaboration; Abreu, P.; et al.

    From a data sample of 9.98 pb-1 integrated luminosity, collected by DELPHI at a centre-of-mass energy of 172 GeV, 118 events were selected as W-pair candidates. From these, the branching fraction Br(W ->q ) was measured to be 0.660+0.036-0.037 ( {stat.}) +/- 0.009 ( {syst.}) and the cross-section for the doubly resonant process hrm e+ e- -> W+ W- to be 11.58+1.44-1.35 ( {stat.}) +/- 0.32 ( {syst.}) pb. The mass of the W boson, obtained from direct reconstruction of the invariant mass of the fermion pairs in the decays { WW -> lν q {q}} and { WW -> q {q}q {q}}, was determined to be mW = \\: 80.22 \\: +/- \\: 0.41 ( {stat.}) \\: +/- 0.04 ( {syst.}) \\: m 0.05 ( {int.}) \\: +/- 0.03 ( {LEP})\\: {GeV}/c2, where ``int.'' denotes the uncertainty from interconnection effects like colour reconnection and Bose-Einstein interference. Combined with the W mass obtained from the cross-sections measured by DELPHI at threshold, a value of mW = \\: 80.33 \\: +/- \\: 0.30 ( {stat.}) \\: +/- 0.05 ({syst.}) \\: +/- \\: 0.03 ( {int.}) \\: +/- \\: 0.03 ( {LEP}) \\: {GeV}/c2 was found.

  7. W5″ Test: A simple method for measuring mean power output in the bench press exercise.

    Science.gov (United States)

    Tous-Fajardo, Julio; Moras, Gerard; Rodríguez-Jiménez, Sergio; Gonzalo-Skok, Oliver; Busquets, Albert; Mujika, Iñigo

    2016-11-01

    The aims of the present study were to assess the validity and reliability of a novel simple test [Five Seconds Power Test (W5″ Test)] for estimating the mean power output during the bench press exercise at different loads, and its sensitivity to detect training-induced changes. Thirty trained young men completed as many repetitions as possible in a time of ≈5 s at 25%, 45%, 65% and 85% of one-repetition maximum (1RM) in two test sessions separated by four days. The number of repetitions, linear displacement of the bar and time needed to complete the test were recorded by two independent testers, and a linear encoder was used as the criterion measure. For each load, the mean power output was calculated in the W5″ Test as mechanical work per time unit and compared with that obtained from the linear encoder. Subsequently, 20 additional subjects (10 training group vs. 10 control group) were assessed before and after completing a seven-week training programme designed to improve maximal power. Results showed that both assessment methods correlated highly in estimating mean power output at different loads (r range: 0.86-0.94; p bench press exercise in subjects who have previous resistance training experience.

  8. Benchmark of AC and DC active power decoupling circuits for second-order harmonic mitigation in kW-scale single-phase inverters

    DEFF Research Database (Denmark)

    Qin, Zian; Tang, Yi; Loh, Poh Chiang

    2015-01-01

    studied, where the commercially available film capacitors, circuit topologies, and control strategies for active power decoupling are all taken into account. Then, an adaptive decoupling voltage control method is proposed to further improve the performance of dc decoupling in terms of efficiency...... and reliability. The feasibility and superiority of the identified solution for active power decoupling together with the proposed adaptive decoupling voltage control method are finally verified by both the experimental results obtained on a 2 kW single-phase inverter.......This paper presents the benchmark study of ac and dc active power decoupling circuits for second-order harmonic mitigation in kW-scale single-phase inverters. First of all, the best solutions of active power decoupling to achieve high efficiency and power density are identified and comprehensively...

  9. Measurement of the $W^{+}W^{-}\\gamma$ Cross Section and Direct Limits on Anomalous Quartic Gauge Couplings at LEP

    CERN Document Server

    Acciarri, M.; Adriani, O.; Aguilar-Benitez, M.; Alcaraz, J.; Alemanni, G.; Allaby, J.; Aloisio, A.; Alviggi, M.G.; Ambrosi, G.; Anderhub, H.; Andreev, Valery P.; Angelescu, T.; Anselmo, F.; Arefev, A.; Azemoon, T.; Aziz, T.; Bagnaia, P.; Bajo, A.; Baksay, L.; Balandras, A.; Baldew, S.V.; Banerjee, S.; Banerjee, Sw.; Barczyk, A.; Barillere, R.; Bartalini, P.; Basile, M.; Battiston, R.; Bay, A.; Becattini, F.; Becker, U.; Behner, F.; Bellucci, L.; Berbeco, R.; Berdugo, J.; Berges, P.; Bertucci, B.; Betev, B.L.; Bhattacharya, S.; Biasini, M.; Biland, A.; Blaising, J.J.; Blyth, S.C.; Bobbink, G.J.; Bohm, A.; Boldizsar, L.; Borgia, B.; Bourilkov, D.; Bourquin, M.; Braccini, S.; Branson, J.G.; Brochu, F.; Buffini, A.; Buijs, A.; Burger, J.D.; Burger, W.J.; Cai, X.D.; Capell, M.; Cara Romeo, G.; Carlino, G.; Cartacci, A.M.; Casaus, J.; Castellini, G.; Cavallari, F.; Cavallo, N.; Cecchi, C.; Cerrada, M.; Cesaroni, F.; Chamizo, M.; Chang, Y.H.; Chaturvedi, U.K.; Chemarin, M.; Chen, A.; Chen, G.; Chen, G.M.; Chen, H.F.; Chen, H.S.; Chiefari, G.; Cifarelli, L.; Cindolo, F.; Civinini, C.; Clare, I.; Clare, R.; Coignet, G.; Colino, N.; Costantini, S.; Cotorobai, F.; de la Cruz, B.; Csilling, A.; Cucciarelli, S.; Dai, T.S.; van Dalen, J.A.; D'Alessandro, R.; de Asmundis, R.; Deglon, P.; Degre, A.; Deiters, K.; della Volpe, D.; Delmeire, E.; Denes, P.; DeNotaristefani, F.; De Salvo, A.; Diemoz, M.; Dierckxsens, M.; van Dierendonck, D.; Dionisi, C.; Dittmar, M.; Dominguez, A.; Doria, A.; Dova, M.T.; Duchesneau, D.; Dufournaud, D.; Duinker, P.; Duran, I.; El Mamouni, H.; Engler, A.; Eppling, F.J.; Erne, F.C.; Extermann, P.; Fabre, M.; Falagan, M.A.; Falciano, S.; Favara, A.; Fay, J.; Fedin, O.; Felcini, M.; Ferguson, T.; Fesefeldt, H.; Fiandrini, E.; Field, J.H.; Filthaut, F.; Fisher, P.H.; Fisk, I.; Forconi, G.; Freudenreich, K.; Furetta, C.; Galaktionov, Iouri; Ganguli, S.N.; Garcia-Abia, Pablo; Gataullin, M.; Gau, S.S.; Gentile, S.; Gheordanescu, N.; Giagu, S.; Gong, Z.F.; Grenier, Gerald Jean; Grimm, O.; Gruenewald, M.W.; Guida, M.; van Gulik, R.; Gupta, V.K.; Gurtu, A.; Gutay, L.J.; Haas, D.; Hasan, A.; Hatzifotiadou, D.; Hebbeker, T.; Herve, Alain; Hidas, P.; Hirschfelder, J.; Hofer, H.; Holzner, G.; Hoorani, H.; Hou, S.R.; Hu, Y.; Iashvili, I.; Jin, B.N.; Jones, Lawrence W.; de Jong, P.; Josa-Mutuberria, I.; Khan, R.A.; Kaur, M.; Kienzle-Focacci, M.N.; Kim, D.; Kim, J.K.; Kirkby, Jasper; Kiss, D.; Kittel, W.; Klimentov, A.; Konig, A.C.; Kopp, A.; Koutsenko, V.; Kraber, M.; Kraemer, R.W.; Krenz, W.; Kruger, A.; Kunin, A.; Ladron de Guevara, P.; Laktineh, I.; Landi, G.; Lebeau, M.; Lebedev, A.; Lebrun, P.; Lecomte, P.; Lecoq, P.; Le Coultre, P.; Lee, H.J.; Le Goff, J.M.; Leiste, R.; Levtchenko, P.; Li, C.; Likhoded, S.; Lin, C.H.; Lin, W.T.; Linde, F.L.; Lista, L.; Liu, Z.A.; Lohmann, W.; Longo, E.; Lu, Y.S.; Lubelsmeyer, K.; Luci, C.; Luckey, David; Lugnier, L.; Luminari, L.; Lustermann, W.; Ma, W.G.; Maity, M.; Malgeri, L.; Malinin, A.; Mana, C.; Mangeol, D.; Mans, J.; Marian, G.; Martin, J.P.; Marzano, F.; Mazumdar, K.; McNeil, R.R.; Mele, S.; Merola, L.; Meschini, M.; Metzger, W.J.; von der Mey, M.; Mihul, A.; Milcent, H.; Mirabelli, G.; Mnich, J.; Mohanty, G.B.; Moulik, T.; Muanza, G.S.; Muijs, A.J.M.; Musicar, B.; Musy, M.; Napolitano, M.; Nessi-Tedaldi, F.; Newman, H.; Niessen, T.; Nisati, A.; Kluge, Hannelies; Ofierzynski, R.; Organtini, G.; Oulianov, A.; Palomares, C.; Pandoulas, D.; Paoletti, S.; Paolucci, P.; Paramatti, R.; Park, H.K.; Park, I.H.; Passaleva, G.; Patricelli, S.; Paul, Thomas Cantzon; Pauluzzi, M.; Paus, C.; Pauss, F.; Pedace, M.; Pensotti, S.; Perret-Gallix, D.; Petersen, B.; Piccolo, D.; Pierella, F.; Pieri, M.; Piroue, P.A.; Pistolesi, E.; Plyaskin, V.; Pohl, M.; Pojidaev, V.; Postema, H.; Pothier, J.; Prokofev, D.O.; Prokofev, D.; Quartieri, J.; Rahal-Callot, G.; Rahaman, M.A.; Raics, P.; Raja, N.; Ramelli, R.; Rancoita, P.G.; Ranieri, R.; Raspereza, A.; Raven, G.; Razis, P.; Ren, D.; Rescigno, M.; Reucroft, S.; Riemann, S.; Riles, Keith; Rodin, J.; Roe, B.P.; Romero, L.; Rosca, A.; Rosier-Lees, S.; Rubio, J.A.; Ruggiero, G.; Rykaczewski, H.; Saremi, S.; Sarkar, S.; Salicio, J.; Sanchez, E.; Sanders, M.P.; Sarakinos, M.E.; Schafer, C.; Schegelsky, V.; Schmidt-Kaerst, S.; Schmitz, D.; Schopper, H.; Schotanus, D.J.; Schwering, G.; Sciacca, C.; Seganti, A.; Servoli, L.; Shevchenko, S.; Shivarov, N.; Shoutko, V.; Shumilov, E.; Shvorob, A.; Siedenburg, T.; Son, D.; Smith, B.; Spillantini, P.; Steuer, M.; Stickland, D.P.; Stone, A.; Stoyanov, B.; Straessner, A.; Sudhakar, K.; Sultanov, G.; Sun, L.Z.; Suter, H.; Swain, J.D.; Szillasi, Z.; Sztaricskai, T.; Tang, X.W.; Tauscher, L.; Taylor, L.; Tellili, B.; Timmermans, Charles; Ting, Samuel C.C.; Ting, S.M.; Tonwar, S.C.; Toth, J.; Tully, C.; Tung, K.L.; Uchida, Y.; Ulbricht, J.; Valente, E.; Vesztergombi, G.; Vetlitsky, I.; Vicinanza, D.; Viertel, G.; Villa, S.; Violini, P.; Vivargent, M.; Vlachos, S.; Vodopianov, I.; Vogel, H.; Vogt, H.; Vorobev, I.; Vorobov, A.A.; Vorvolakos, A.; Wadhwa, M.; Wallraff, W.; Wang, M.; Wang, X.L.; Wang, Z.M.; Weber, A.; Weber, M.; Wienemann, P.; Wilkens, H.; Wu, S.X.; Wynhoff, S.; Xia, L.; Xu, Z.Z.; Yamamoto, J.; Yang, B.Z.; Yang, C.G.; Yang, H.J.; Yang, M.; Ye, J.B.; Yeh, S.C.; Zalite, An.; Zalite, Yu.; Zhang, Z.P.; Zhu, G.Y.; Zhu, R.Y.; Zichichi, A.; Zilizi, G.; Zimmermann, B.; Zoller, M.

    2000-01-01

    The process e$^+$e$^-\\rightarrow {\\rm W}^+{\\rm W}^-\\gamma$ is analysed using the data collected with the L3 detector at LEP at a centre-of-mass energy of $188.6$ GeV, corresponding to an integrated luminosity of 176.8 pb$^{-1}$. Based on a sample of 42 selected ${\\rm W}^+{\\rm W}^-$ candidates containing an isolated hard photon, the ${\\rm W}^+{\\rm W}^-\\gamma$ cross section, defined within phase-space cuts, is measured to be: $\\sigma_{{\\rm WW}\\gamma} = 290 \\pm 80 \\pm 16$ fb, consistent with the Standard Model expectation. Including the process e$^+$e$^-\\rightarrow \

  10. Effects of Plyometric and Cluster Resistance Training on Explosive Power and Maximum Strength in Karate Players

    Directory of Open Access Journals (Sweden)

    Mohsen Aminaei

    2017-08-01

    Full Text Available The purpose of this study was to investigate the effects of plyometric and cluster resistance training on explosive power and maximum strength in karate players. Eighteen women, karate players (age mean ± SD 18.22 ± 3.02 years, mean height 163 ± 0.63cm, and mean body mass 53.25 ± 7.34 kg were selected as volunteer samples. They were divided into two groups with respect to their recorded one repetition maximum squat exercise: [1] plyometric training (PT=9 and [2] Cluster training (CT=9 groups and performed a 9-week resistance training protocol that included three stages; [1] General fitness (2 weeks, [2] Strength (4 weeks and [3] Power (3 weeks. Each group performed strength and power trainings for 7 weeks in stage two and three with owned protocol. The subjects were evaluated three times before stage one and after two and three stages for maximum strength and power. Data was analyzed using two way Repeated Measures (ANOVA at a significance level of (P≤0.05. The statistical analysis showed that training stages on all research variables had a significant impact. The maximum strength of the pre-test, post-test strength and post-test power were in cluster group: 29.05 ± 1.54; 32.89 ± 2.80 and 48.74 ± 4.33w and in plyometric group were 26.98 ± 1.54; 38.48 ± 2.80 and 49.82 ± 4.33w respectively. The explosive power of the pre-test, post-test strength and post-test power in cluster group were 359.32±36.20; 427.91±34.56 and 460.55±36.80w and in plyometric group were 333.90±36.20; 400.33±34.56 and 465.20±36.80w respectively. However, there were not statistically significant differences in research variables between resistance cluster and plyometric training groups after 7 weeks. The results indicated both cluster and plyometric training program seems to improve physical fitness elements at the same levels.

  11. Radiation power profiles and density limit with a divertor in the W7-AS stellarator

    International Nuclear Information System (INIS)

    Giannone, L.; Burhenn, R.; McCormick, K.; Brakel, R.; Feng, Y.; Grigull, P.; Igitkhanov, Y.

    2002-01-01

    The addition of a divertor into the W7-AS stellarator has allowed access to a high density regime where the radiation profiles reach a steady state. In earlier limiter discharges, the plasma suffered a radiative collapse at high densities. In contrast to limiter experiments, where the impurity confinement time measured by Al laser blow-off increased with increasing line integrated density, in divertor discharges, above a density threshold, the impurity confinement time decreased with increasing line integrated density. The observation that the divertor plasma radiates mainly at the plasma edge rather than the plasma centre is a further indication that changes to the impurity transport coefficients at these high densities are the basis for the achievement of steady state discharges in the divertor configuration of W7-AS. The maximum line integrated density reached with a divertor is compared to that reached with a limiter. The previously derived scaling law for the density limit with a limiter shows that the achieved densities do not exceed those predicted when the higher deposited power is taken into account. In a divertor the radiated power is located at the plasma edge and increasing the density, cooling the plasma edge and radiating sufficient power to cause plasma detachment determines the density limit. (author)

  12. Operating characteristics of a single-stage Stirling cryocooler capable of providing 700 W cooling power at 77 K

    Science.gov (United States)

    Xu, Ya; Sun, Daming; Qiao, Xin; Yu, Yan S. W.; Zhang, Ning; Zhang, Jie; Cai, Yachao

    2017-04-01

    High cooling capacity Stirling cryocooler generally has hundreds to thousands watts of cooling power at liquid nitrogen temperature. It is promising in boil-off gas (BOG) recondensation and high temperature superconducting (HTS) applications. A high cooling capacity Stirling cryocooler driven by a crank-rod mechanism was developed and studied systematically. The pressure and frequency characteristics of the cryocooler, the heat rejection from the ambient heat exchanger, and the cooling performance are studied under different charging pressure. Energy conversion and distribution in the cryocooler are analyzed theoretically. With an electric input power of 10.9 kW and a rotating speed of 1450 r/min of the motor, a cooling power of 700 W at 77 K and a relative Carnot efficiency of 18.2% of the cryocooler have been achieved in the present study, and the corresponding pressure ratio in the compression space reaches 2.46.

  13. A Mid-IR 14.1 W ZnGeP{sub 2} Optical Parametric Oscillator Pumped by a Tm,Ho:GdVO{sub 4} Laser

    Energy Technology Data Exchange (ETDEWEB)

    Guo-Li, Zhu; You-Lun, Ju; Tian-Heng, Wang; Yue-Zhu, Wang [National Key Laboratory of Tunable Laser Technology, Harbin Institute of Technology, Harbin 150001 (China)

    2009-03-15

    We report a high power and high efficiency double resonant ZnGeP{sub 2} (ZGP) optical parametric oscillator (OPO) pumped by a Tm,Ho:GdVO{sub 4} laser. We employ a Tm,Ho:GdVO{sub 4} laser as the pump source operated at 2.049 {mu}m with M{sup 2} = 1.1. The ZGP OPO can generate a total combined output power of 14.1 W at 3.80 {mu}m signal and 4.45 {mu}m idler under pumping power of 28.7 W. The slope efficiency reaches 61.8%, and M{sup 2} = 3.6 for OPO output is obtained. (fundamental areas of phenomenology (including applications))

  14. Combined Heat and Power Systems Technology Development and Demonstration 370 kW High Efficiency Microturbine

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2015-10-14

    The C370 Program was awarded in October 2010 with the ambitious goal of designing and testing the most electrically efficient recuperated microturbine engine at a rated power of less than 500 kW. The aggressive targets for electrical efficiency, emission regulatory compliance, and the estimated price point make the system state-of-the-art for microturbine engine systems. These goals will be met by designing a two stage microturbine engine identified as the low pressure spool and high pressure spool that are based on derivative hardware of Capstone’s current commercially available engines. The development and testing of the engine occurred in two phases. Phase I focused on developing a higher power and more efficient engine, that would become the low pressure spool which is based on Capstone’s C200 (200kW) engine architecture. Phase II integrated the low pressure spool created in Phase I with the high pressure spool, which is based on Capstone’s C65 (65 kW) commercially available engine. Integration of the engines, based on preliminary research, would allow the dual spool engine to provide electrical power in excess of 370 kW, with electrical efficiency approaching 42%. If both of these targets were met coupled with the overall CHP target of 85% total combined heating and electrical efficiency California Air Resources Board (CARB) level emissions, and a price target of $600 per kW, the system would represent a step change in the currently available commercial generation technology. Phase I of the C370 program required the development of the C370 low pressure spool. The goal was to increase the C200 engine power by a minimum of 25% — 250 kW — and efficiency from 32% to 37%. These increases in the C200 engine output were imperative to meet the power requirements of the engine when both spools were integrated. An additional benefit of designing and testing the C370 low pressure spool was the possibility of developing a stand-alone product for possible

  15. A Power Case Study for Monocrystalline and Polycrystalline Solar Panels in Bursa City, Turkey

    Directory of Open Access Journals (Sweden)

    Ayşegül Taşçıoğlu

    2016-01-01

    Full Text Available It was intended to reveal the time dependent power generation under different loads for two different solar panels under the conditions of Bursa province in between August 19 and 25, 2014. The testing sets include solar panels, inverter, multimeter, accumulator, regulator, pyranometer, pyrheliometer, temperature sensor, and datalogger. The efficiency of monocrystalline and polycrystalline solar panels was calculated depending on the climatic data’s measurements. As the result of the study, the average performances of monocrystalline and polycrystalline panels are 42.06 and 39.80 Wh, respectively. It was seen that 87.14 W instantaneous power could be obtained from monocrystalline solar panel and that 80.17 W instantaneous power could be obtained from polycrystalline solar panel under maximum total radiation (1001.13 W/m2. Within this frame, it was determined that monocrystalline solar panel is able to operate more efficiently under the conditions of Bursa compared to polycrystalline solar panel. When the multivariate correlations coefficients were examined statistically, a significant relationship in positive direction was detected between total and direct radiation and ambient temperature on energy generation from monocrystalline and polycrystalline panel.

  16. Effects of high power ion Bernstein waves on a tokamak plasma

    International Nuclear Information System (INIS)

    Ono, M.; Beiersdorfer, P.; Bell, R.

    1987-04-01

    Ion Bernstein wave heating (IBWH) has been investigated on PLT with up to 650 kW of rf power coupled to the plasma, exceeding the ohmic power of 550 kW. Plasma antenna loading of 2 Ω has been observed, resulting in 80 to 90% of the rf power being coupled to the plasma. An ion heating efficiency of ΔT/sub i/(0)n/sub e//P/sub rf/ = 6 x 10 13 eV cm -3 /kW, without high energy tail ions, has been observed up to the maximum rf power. The deuterium particle confinement during high power IBWH increases significantly (as much as 300%). Associated with it, a longer injected impurity confinement time, reduced drift wave turbulence activity, frequency shifts of drfit wave turbulence, and development of a large negative edge potential were observed. The energy confinement time, however, shows some degradation from the ohmic value, which can be attributed to the enhanced radiation loss observed during IBWH. The ion heating and energy confinement time are relatively independent of plasma current

  17. 600W uninterruptible power supply

    Energy Technology Data Exchange (ETDEWEB)

    Frizell, C

    1988-01-01

    Although the mains power supply in western Europe is normally reliable, power failures, transients and noise can cause loss or corruption of data held on personal computers. The design of an uninterruptible power supply system (UPS) based on well proven technology, is described.

  18. Precise measurement of the $W$-boson mass with the CDF II detector

    Energy Technology Data Exchange (ETDEWEB)

    Aaltonen, T.; /Helsinki Inst. of Phys.; Alvarez Gonzalez, B.; /Oviedo U. /Cantabria Inst. of Phys.; Amerio, S.; /INFN, Padua; Amidei, D.; /Michigan U.; Anastassov, A.; /Northwestern U. /Fermilab; Annovi, A.; /Frascati; Antos, J.; /Comenius U.; Apollinari, G.; /Fermilab; Appel, J.A.; /Fermilab; Arisawa, T.; /Waseda U.; Artikov, A.; /Dubna, JINR /Texas A-M

    2012-03-01

    We have measured the W-boson mass M{sub W} using data corresponding to 2.2 fb{sup -1} of integrated luminosity collected in p{bar p} collisions at {radical}s = 1.96 TeV with the CDF II detector at the Fermilab Tevatron collider. Samples consisting of 470 126 W {yields} e{nu} candidates and 624 708 W {yields} {mu}{nu} candidates yield the measurement M{sub W} = 80 387 {+-} 12{sub stat} {+-} 15{sub syst} = 80 387 {+-} 19 MeV/c{sup 2}. This is the most precise measurement of the W-boson mass to date and significantly exceeds the precision of all previous measurements combined.

  19. Design, integration and demonstration of a 50 W JP8/kerosene fueled portable SOFC power generator

    Science.gov (United States)

    Cheekatamarla, Praveen K.; Finnerty, Caine M.; Robinson, Charles R.; Andrews, Stanley M.; Brodie, Jonathan A.; Lu, Y.; DeWald, Paul G.

    A man-portable solid oxide fuel cell (SOFC) system integrated with desulfurized JP8 partial oxidation (POX) reformer was demonstrated to supply a continuous power output of 50 W. This paper discusses some of the design paths chosen and challenges faced during the thermal integration of the stack and reformer in aiding the system startup and shutdown along with balance of plant and power management solutions. The package design, system capabilities, and test results of the prototype unit are presented.

  20. W-Band Sheet Beam Klystron Design

    International Nuclear Information System (INIS)

    Scheitrum, G.; Caryotakis, G.; Burke, A.; Jensen, A.; Jongewaard, E.; Krasnykh, A.; Neubauer, M.; Phillips, R.; Rauenbuehler, K.

    2011-01-01

    Sheet beam devices provide important advantages for very high power, narrow bandwidth RF sources like accelerator klystrons (1). Reduced current density and increased surface area result in increased power capabi1ity, reduced magnetic fields for focusing and reduced cathode loading. These advantages are offset by increased complexity, beam formation and transport issues and potential for mode competition in the ovennoded cavities and drift tube. This paper will describe the design issues encountered in developing a 100 kW peak and 2 kW average power sheet beam k1ystron at W-band including beam formation, beam transport, circuit design, circuit fabrication and mode competition.

  1. Ultrasound assisted destruction of estrogen hormones in aqueous solution: Effect of power density, power intensity and reactor configuration

    International Nuclear Information System (INIS)

    Suri, Rominder P.S.; Nayak, Mohan; Devaiah, Uthappa; Helmig, Edward

    2007-01-01

    There are many reports documenting the adverse effects, such as feminization of fish, of estrogen hormones in the environment. One of the major sources of these compounds is from municipal wastewater effluents. The biological processes at municipal wastewater treatment plants cannot completely remove these compounds. This paper discusses the use of ultrasound to destroy estrogen compounds in water. The study examines the effect of ultrasound power density and power intensity on the destruction of various estrogen compounds which include: 17α-estradiol, 17β-estradiol, estrone, estriol, equilin, 17α-dihydroequilin, 17α-ethinyl estradiol and norgestrel. These tests were conducted in single component batch and flow through reactors using 0.6, 2 and 4 kW ultrasound sources. The sonolysis process produced 80-90% destruction of individual estrogens at initial concentration of 10 μg/L within 40-60 min of contact time. First order rate constants for the individual compounds under different conditions are presented. The estrogen degradation rates increase with increase in power intensity. However, the energy efficiency of the reactor was higher at lower power density. The 4 kW ultrasound reactor was more energy efficient compared to the 0.6 and 2 kW sonicators

  2. First measurement of the W-boson mass in run II of the Tevatron.

    Science.gov (United States)

    Aaltonen, T; Abulencia, A; Adelman, J; Affolder, T; Akimoto, T; Albrow, M G; Amerio, S; Amidei, D; Anastassov, A; Anikeev, K; Annovi, A; Antos, J; Aoki, M; Apollinari, G; Arisawa, T; Artikov, A; Ashmanskas, W; Attal, A; Aurisano, A; Azfar, F; Azzi-Bacchetta, P; Azzurri, P; Bacchetta, N; Badgett, W; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Baroiant, S; Bartsch, V; Bauer, G; Beauchemin, P-H; Bedeschi, F; Behari, S; Bellettini, G; Bellinger, J; Belloni, A; Benjamin, D; Beretvas, A; Beringer, J; Berry, T; Bhatti, A; Binkley, M; Bisello, D; Bizjak, I; Blair, R E; Blocker, C; Blumenfeld, B; Bocci, A; Bodek, A; Boisvert, V; Bolla, G; Bolshov, A; Bortoletto, D; Boudreau, J; Boveia, A; Brau, B; Brigliadori, L; Bromberg, C; Brubaker, E; Budagov, J; Budd, H S; Budd, S; Burkett, K; Busetto, G; Bussey, P; Buzatu, A; Byrum, K L; Cabrera, S; Campanelli, M; Campbell, M; Canelli, F; Canepa, A; Carrillo, S; Carlsmith, D; Carosi, R; Carron, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chang, S H; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, I; Cho, K; Chokheli, D; Chou, J P; Choudalakis, G; Chuang, S H; Chung, K; Chung, W H; Chung, Y S; Cilijak, M; Ciobanu, C I; Ciocci, M A; Clark, A; Clark, D; Coca, M; Compostella, G; Convery, M E; Conway, J; Cooper, B; Copic, K; Cordelli, M; Cortiana, G; Crescioli, F; Almenar, C Cuenca; Cuevas, J; Culbertson, R; Cully, J C; Daronco, S; Datta, M; D'Auria, S; Davies, T; Dagenhart, D; de Barbaro, P; De Cecco, S; Deisher, A; De Lentdecker, G; De Lorenzo, G; Dell'orso, M; Delli Paoli, F; Demortier, L; Deng, J; Deninno, M; De Pedis, D; Derwent, P F; Di Giovanni, G P; Dionisi, C; Di Ruzza, B; Dittmann, J R; D'Onofrio, M; Dörr, C; Donati, S; Dong, P; Donini, J; Dorigo, T; Dube, S; Efron, J; Erbacher, R; Errede, D; Errede, S; Eusebi, R; Fang, H C; Farrington, S; Fedorko, I; Fedorko, W T; Feild, R G; Feindt, M; Fernandez, J P; Field, R; Flanagan, G; Forrest, R; Forrester, S; Franklin, M; Freeman, J C; Furic, I; Gallinaro, M; Galyardt, J; Garcia, J E; Garberson, F; Garfinkel, A F; Gay, C; Gerberich, H; Gerdes, D; Giagu, S; Giannetti, P; Gibson, K; Gimmell, J L; Ginsburg, C; Giokaris, N; Giordani, M; Giromini, P; Giunta, M; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldschmidt, N; Goldstein, J; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Goulianos, K; Gresele, A; Grinstein, S; Grosso-Pilcher, C; Grundler, U; da Costa, J Guimaraes; Gunay-Unalan, Z; Haber, C; Hahn, K; Hahn, S R; Halkiadakis, E; Hamilton, A; Han, B-Y; Han, J Y; Handler, R; Happacher, F; Hara, K; Hare, D; Hare, M; Harper, S; Harr, R F; Harris, R M; Hartz, M; Hatakeyama, K; Hauser, J; Hays, C; Heck, M; Heijboer, A; Heinemann, B; Heinrich, J; Henderson, C; Herndon, M; Heuser, J; Hidas, D; Hill, C S; Hirschbuehl, D; Hocker, A; Holloway, A; Hou, S; Houlden, M; Hsu, S-C; Huffman, B T; Hughes, R E; Husemann, U; Huston, J; Incandela, J; Introzzi, G; Iori, M; Ivanov, A; Iyutin, B; James, E; Jang, D; Jayatilaka, B; Jeans, D; Jeon, E J; Jindariani, S; Johnson, W; Jones, M; Joo, K K; Jun, S Y; Jung, J E; Junk, T R; Kamon, T; Karchin, P E; Kato, Y; Kemp, Y; Kephart, R; Kerzel, U; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, S B; Kim, S H; Kim, Y K; Kimura, N; Kirsch, L; Klimenko, S; Klute, M; Knuteson, B; Ko, B R; Kondo, K; Kong, D J; Konigsberg, J; Korytov, A; Kotwal, A V; Kraan, A C; Kraus, J; Kreps, M; Kroll, J; Krumnack, N; Kruse, M; Krutelyov, V; Kubo, T; Kuhlmann, S E; Kuhr, T; Kulkarni, N P; Kusakabe, Y; Kwang, S; Laasanen, A T; Lai, S; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; Lazzizzera, I; Lecompte, T; Lee, J; Lee, J; Lee, Y J; Lee, S W; Lefèvre, R; Leonardo, N; Leone, S; Levy, S; Lewis, J D; Lin, C; Lin, C S; Lindgren, M; Lipeles, E; Liss, T M; Lister, A; Litvintsev, D O; Liu, T; Lockyer, N S; Loginov, A; Loreti, M; Lu, R-S; Lucchesi, D; Lujan, P; Lukens, P; Lungu, G; Lyons, L; Lys, J; Lysak, R; Lytken, E; Mack, P; Macqueen, D; Madrak, R; Maeshima, K; Makhoul, K; Maki, T; Maksimovic, P; Malde, S; Malik, S; Manca, G; Manousakis, A; Margaroli, F; Marginean, R; Marino, C; Marino, C P; Martin, A; Martin, M; Martin, V; Martínez, M; Martínez-Ballarín, R; Maruyama, T; Mastrandrea, P; Masubuchi, T; Matsunaga, H; Mattson, M E; Mazini, R; Mazzanti, P; McFarland, K S; McIntyre, P; McNulty, R; Mehta, A; Mehtala, P; Menzemer, S; Menzione, A; Merkel, P; Mesropian, C; Messina, A; Miao, T; Miladinovic, N; Miles, J; Miller, R; Mills, C; Milnik, M; Mitra, A; Mitselmakher, G; Miyamoto, A; Moed, S; Moggi, N; Mohr, B; Moon, C S; Moore, R; Morello, M; Fernandez, P Movilla; Mülmenstädt, J; Mukherjee, A; Muller, Th; Mumford, R; Murat, P; Mussini, M; Nachtman, J; Nagano, A; Naganoma, J; Nakamura, K; Nakano, I; Napier, A; Necula, V; Neu, C; Neubauer, M S; Nielsen, J; Nodulman, L; Norniella, O; Nurse, E; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Oldeman, R; Orava, R; Osterberg, K; Pagliarone, C; Palencia, E; Papadimitriou, V; Papaikonomou, A; Paramonov, A A; Parks, B; Pashapour, S; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Piedra, J; Pinera, L; Pitts, K; Plager, C; Pondrom, L; Portell, X; Poukhov, O; Pounder, N; Prakoshyn, F; Pronko, A; Proudfoot, J; Ptohos, F; Punzi, G; Pursley, J; Rademacker, J; Rahaman, A; Ramakrishnan, V; Ranjan, N; Redondo, I; Reisert, B; Rekovic, V; Renton, P; Rescigno, M; Richter, S; Rimondi, F; Ristori, L; Robson, A; Rodrigo, T; Rogers, E; Rolli, S; Roser, R; Rossi, M; Rossin, R; Roy, P; Ruiz, A; Russ, J; Rusu, V; Saarikko, H; Safonov, A; Sakumoto, W K; Salamanna, G; Saltó, O; Santi, L; Sarkar, S; Sartori, L; Sato, K; Savard, P; Savoy-Navarro, A; Scheidle, T; Schlabach, P; Schmidt, E E; Schmidt, M P; Schmitt, M; Schwarz, T; Scodellaro, L; Scott, A L; Scribano, A; Scuri, F; Sedov, A; Seidel, S; Seiya, Y; Semenov, A; Sexton-Kennedy, L; Sfyrla, A; Shalhout, S Z; Shapiro, M D; Shears, T; Shepard, P F; Sherman, D; Shimojima, M; Shochet, M; Shon, Y; Shreyber, I; Sidoti, A; Sinervo, P; Sisakyan, A; Slaughter, A J; Slaunwhite, J; Sliwa, K; Smith, J R; Snider, F D; Snihur, R; Soderberg, M; Soha, A; Somalwar, S; Sorin, V; Spalding, J; Spinella, F; Spreitzer, T; Squillacioti, P; Stanitzki, M; Staveris-Polykalas, A; Denis, R St; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Stuart, D; Suh, J S; Sukhanov, A; Sun, H; Suslov, I; Suzuki, T; Taffard, A; Takashima, R; Takeuchi, Y; Tanaka, R; Tecchio, M; Teng, P K; Terashi, K; Thom, J; Thompson, A S; Thomson, E; Tipton, P; Tiwari, V; Tkaczyk, S; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Tourneur, S; Trischuk, W; Tsuno, S; Tu, Y; Turini, N; Ukegawa, F; Uozumi, S; Vallecorsa, S; van Remortel, N; Varganov, A; Vataga, E; Vazquez, F; Velev, G; Vellidis, C; Veramendi, G; Veszpremi, V; Vidal, M; Vidal, R; Vila, I; Vilar, R; Vine, T; Vogel, M; Vollrath, I; Volobouev, I; Volpi, G; Würthwein, F; Wagner, P; Wagner, R G; Wagner, R L; Wagner, J; Wagner, W; Wallny, R; Wang, S M; Warburton, A; Waters, D; Weinberger, M; Wester, W C; Whitehouse, B; Whiteson, D; Wicklund, A B; Wicklund, E; Williams, G; Williams, H H; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, C; Wright, T; Wu, X; Wynne, S M; Yagil, A; Yamamoto, K; Yamaoka, J; Yamashita, T; Yang, C; Yang, U K; Yang, Y C; Yao, W M; Yeh, G P; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Yu, S S; Yun, J C; Zanello, L; Zanetti, A; Zaw, I; Zhang, X; Zhou, J; Zucchelli, S

    2007-10-12

    We present a measurement of the W-boson mass using 200 pb{-1} of data collected in pp[over ] collisions at sqrt[s]=1.96 TeV by the CDF II detector at run II of the Fermilab Tevatron. With a sample of 63 964 W-->enu candidates and 51 128 W-->munu candidates, we measure M_{W}=80 413+/-34{stat}+/-34{syst}=80,413+/-48 MeV/c;{2}. This is the most precise single measurement of the W-boson mass to date.

  3. Impact of size and distribution of installed PV power in E-W direction on the level in which selected consumers’ energy needs were met

    Directory of Open Access Journals (Sweden)

    Necka Krzysztof

    2018-01-01

    Full Text Available The aim of the study was to analyse the energy needs of selected consumers and to select the PV installed capacity in the east and west panels orientation (E-W. The analysis was carried out for two variants. The first concerned the impact of the installation power of a PV source on the contracted power in its symmetric east and west position. The second variant was the result of previous observations and studies of the authors of this paper. Thus, in this variant, the unbalanced power of PV E-W in relation to the S azimuth has been analyzed, taking into account the characteristics of the recipients' needs and the variation of the PV power installed. The analyses show that an increase in meeting the energy demand for two of the tested plants at symmetrical power distribution to the east and west occurred only when the installed power was increased to the level of approx. 1.4-1.6 of the contracted power. However, the power distribution in the E-W direction has a very strong effect on the energy amount that is generated in the power plant and cannot be used due to the lack of demand in the plant.

  4. Use of potassium titanyl phosphate (KTP) laser Dermastat in the treatment of recurrent anterior epistaxis - a new technique.

    Science.gov (United States)

    Jain, A; Frampton, S J; Sachidananda, R; Jain, P K

    2016-09-01

    To evaluate the short- to medium-term effectiveness of potassium titanyl phosphate (KTP) laser Dermastat in patients with recurrent anterior epistaxis. Fifty-eight patients presenting with recurrent anterior epistaxis were treated using potassium titanyl phosphate laser Dermastat. Those with recurrent epistaxis arising from prominent vessels in Little's area, and/or those for whom treatment with silver nitrate cautery failed, were included. The main outcome measure was resolution of epistaxis at two months. Fifty-eight patients were treated; 27 were under 18 years old. Thirty patients had prominent vessels. Thirty-one patients had undergone previous cautery treatment. Thirty-eight patients had treatment to the left side, 19 to the right and 1 to both. At two months, 74 per cent reported resolution of epistaxis with no complications. This increased to 78 per cent at further follow up. Our technique is a successful, safe treatment for recurrent anterior epistaxis in an otherwise treatment-resistant group. A single procedure is effective. The handpiece and tip are reusable and sterilisable, resulting in cost-effectiveness.

  5. Numerical analysis on the performance of solar chimney power plant system

    International Nuclear Information System (INIS)

    Xu Guoliang; Ming Tingzhen; Pan Yuan; Meng Fanlong; Zhou Cheng

    2011-01-01

    Power generating technology based on renewable energy resources will definitely become a new trend of future energy utilization. Numerical simulations on air flow, heat transfer and power output characteristics of a solar chimney power plant model with energy storage layer and turbine similar to the Spanish prototype were carried out in this paper, and mathematical model of flow and heat transfer for the solar chimney power plant system was established. The influences of solar radiation and pressure drop across the turbine on the flow and heat transfer, output power and energy loss of the solar chimney power plant system were analyzed. The numerical simulation results reveal that: when the solar radiation and the turbine efficiency are 600 W/m 2 and 80%, respectively, the output power of the system can reach 120 kW. In addition, large mass flow rate of air flowing through the chimney outlet become the main cause of energy loss in the system, and the collector canopy also results in large energy loss.

  6. Stable, high power, high efficiency picosecond ultraviolet generation at 355 nm in K3B6O10 Br crystal

    Science.gov (United States)

    Hou, Z. Y.; Wang, L. R.; Xia, M. J.; Yan, D. X.; Zhang, Q. L.; Zhang, L.; Liu, L. J.; Xu, D. G.; Zhang, D. X.; Wang, X. Y.; Li, R. K.; Chen, C. T.

    2018-06-01

    We demonstrate a high efficiency and high power picosecond ultraviolet source at 355 nm with stable output by sum frequency generation from a Nd:YAG laser using a type-I critically phase matched K3B6O10 Br crystal as nonlinear optical material. Conversion efficiency as high as 30.8% was achieved using a 25 ps laser at 1064 nm operated at 10 Hz. Similar work is done by using a 35 W 10 ps laser at 1064 nm as the pump source with a repetition rate of 80 MHz, and the highest average output power obtained was up to 5.3 W. In addition, the power stability of the 355 nm output power measurement shows that the standard deviation fluctuations of the average power are ±0.69% and ±0.91% at 3.0 W and 3.5 W, respectively.

  7. Gyrocon radio-frequency generator for FY-80 and FY-81

    International Nuclear Information System (INIS)

    Tallerico, P.J.

    1982-09-01

    The gyrocon is a high-power, high-efficiency amplifier that operates by deflection modulation of an electron beam. The spatial bunching can be better than the temporal bunching in a klystron, especially for high output powers and uhf frequencies. Soviet gyrocons have produced over 40 MW of pulsed power at 430 MHz and 250-kW cw at 181 MHz. The progress on the construction and testing of a 450-MHz prototype gyrocon is discussed. The maximum pulsed output power that has been achieved in the reporting period is 1 kW. Although these powers are significantly below the design goal of 650 kW, there is a good chance that the experimental program in FY-82 will result in increased output power

  8. Study of thermal interaction between a 150 kW CW power coupler and a superconducting 704 MHz elliptical cavity

    Energy Technology Data Exchange (ETDEWEB)

    Souli, M. [Institut de Physique Nucleaire d' Orsay, CNRS/IN2P3, Orsay (France)]. E-mail: souli@ipno.in2p3.fr; Fouaidy, M. [Institut de Physique Nucleaire d' Orsay, CNRS/IN2P3, Orsay (France); Saugnac, H. [Institut de Physique Nucleaire d' Orsay, CNRS/IN2P3, Orsay (France); Szott, P. [Institut de Physique Nucleaire d' Orsay, CNRS/IN2P3, Orsay (France); Gandolfo, N. [Institut de Physique Nucleaire d' Orsay, CNRS/IN2P3, Orsay (France); Bousson, S. [Institut de Physique Nucleaire d' Orsay, CNRS/IN2P3, Orsay (France); Braud, D. [CEA Saclay, DSM/DAPNIA/SACM, 91191 Gif sur Yvette (France); Charrier, J.P. [CEA Saclay, DSM/DAPNIA/SACM, 91191 Gif sur Yvette (France); Roudier, D. [CEA Saclay, DSM/DAPNIA/SACM, 91191 Gif sur Yvette (France); Sahuquet, P. [CEA Saclay, DSM/DAPNIA/SACM, 91191 Gif sur Yvette (France); Visentin, B. [CEA Saclay, DSM/DAPNIA/SACM, 91191 Gif sur Yvette (France)

    2006-07-15

    The power coupler needed for {beta} = 0.65 SRF elliptical cavities dedicated to the driver of XADS (eXperimental Accelerator Driven System) should transmit a CW RF power of 150 kW to a 10 mA proton beam. The estimated average values of the RF losses in the coupler are 130 W (respectively 46 W) for the inner (respectively outer) conductor in SW mode. Due to such high values of the RF losses, it is necessary to very carefully design and optimize the cooling circuits of the coupler in order to efficiently remove the generated heat and to reduce the thermal load to the cavity operating at T = 2 K. An experiment simulating the thermal interaction between the power coupler and a 704 MHz SRF five cells cavity was performed in the CRYHOLAB test facility in order to determine the critical heat load that can be sustained by the cavity without degradation of its RF performance. Experimental data are compared to numerical simulation results obtained with the Finite Element Method code COSMOS/M. These data allow us also to perform in situ measurements of the thermal parameters needed in the thermal model of the coupler (thermal conductivity, thermal contact resistance). These data are used to validate numerical simulations.

  9. Safety assessment of unit 5 (WWER-440/W-213) of the Greifswald nuclear power station

    International Nuclear Information System (INIS)

    1992-02-01

    The report represents the common results of the program of German-Soviet cooperation in reactor safety and radiation protection. The technical plant and features of type WWER-440/W-213 nuclear power plants, basic legal licensing principles, reactor core and pressurized components, load resulting from accidents, systems engineering, spreading impacts, civil engineering aspects, and the evaluation of operating experience are described. (DG)

  10. Experimental test of a supercritical helium heat exchanger dedicated to EUROTRANS 150 kW CW power coupler

    Science.gov (United States)

    Souli, M.; Fouaidy, M.; Hammoudi, N.

    2010-05-01

    The coaxial power coupler needed for beta = 0.65 superconducting RF cavities used in the high energy section of the EUROTRANS driver should transmit 150 kW (CW operation) RF power to the proton beam. The estimated RF losses on the power coupler outer conductor in standing wave mode operation are 46 W. To remove these heat loads, a full scale copper coil heat exchanger brazed around the outer conductor was designed and tested using supercritical helium at T = 6 K as a coolant. Our main objective was to minimise the heat loads to cold extremity of SRF cavity maintained at 2 K or 4.2 K. A dedicated test facility named SUPERCRYLOOP was developed and successfully operated in order to measure the performance of the cold heat exchanger. The test cell used reproduces the realistic thermal boundary conditions of the power coupler mounted on the cavity in the cryomodule. After a short introduction, a brief discussion about the problem of power coupler cooling systems in different machines is made. After that, we describe the experimental set-up and test apparatus. Then, a heat exchanger thermal model will be developed with FEM code COSMOS/M to estimate the different heat transfer coefficients by comparison between numerical simulation results and experimental data in order to validate the design. Finally, thermo-hydraulic behavior of supercritical helium has been investigated as function of different parameters (inlet pressure, flow rate, heat loads).

  11. Experimental and computational analysis of a 1.2 kW PEMFC designed for communications backup power applications

    International Nuclear Information System (INIS)

    Krishnan, K.J.; Claveria, J.; Varadharajan, L.; Kalam, A.

    2011-01-01

    Usage of Fuel Cells due to their high power density and low greenhouse gas emissions which combine H/sub 2/ and O/sub 2/ electrochemically to produce electricity and H/sub 2/O as the by-product will become widespread in the near future due to its quality, reliability and portability. Among all types of fuel cells, Proton Exchange Membrane Fuel Cells (PEMFC) is most attractive for residential and automotive industry use due to its low operating temperature, silent operation, quick start-up characteristics and better performance. The T-1000 1.2 kW PEMFC are mainly used for communications backup power applications because of its high reliability, simplicity and ease of maintenance in telecommunication sector, utility and government etc. This paper discuses the features of T- 1000 PEMFC and also the production losses due to power outages in US and different parts of the globe and the advantages of using it in different sectors to reduce the production loses occurred by the power outages. This work focuses on the experimental data and the computational data of load, P, V, A and H/sub 2/ consumed under laboratory conditions at Power Lab in Victoria University, Melbourne. The paper also describes various load, P, V and A curves recorded at regular intervals between the experimental and computational data. The work shows notably the benefit of using T-1000 1.2 kW PEMFC for residential, automobile, government and telecom sectors. (author)

  12. Wireless data and power transfer of an optogenetic implantable visual cortex stimulator.

    Science.gov (United States)

    Fattah, Nabeel; Laha, Soumyasanta; Sokolov, Danil; Chester, Graeme; Degenaar, Patrick

    2015-08-01

    In this paper, the wireless data and power transfer for a novel optogenetic visual cortex implant system was demonstrated by using pork tissue mimic in-vitro at the ISM 2.4 GHz and 13.5 MHz frequency band respectively. The observed data rate was 120 kbps with no loss in data for up to a thickness of 35 mm in both water & pork. To increase the power level of the implant a Class E power amplifier is separately designed and simulated for the transmitter end and has an output power of around 223 mW with an efficiency of 81.83%. The transferred power at the receiver was measured to be 66.80 mW for the pork tissue medium considering a distance of 5 mm between the transmitter and the receiver coils, with a coupling coefficient of ~0.8. This serves the power requirement of the visual cortex implant.

  13. Cochlear Outer-Hair-Cell Power Generation and Viscous Fluid Loss

    Science.gov (United States)

    Wang, Yanli; Steele, Charles R.; Puria, Sunil

    2016-01-01

    Since the discovery of otoacoustic emissions and outer hair cell (OHC) motility, the fundamental question of whether the cochlea produces mechanical power remains controversial. In the present work, direct calculations are performed on power loss due to fluid viscosity and power generated by the OHCs. A three-dimensional box model of the mouse cochlea is used with a feed-forward/feed-backward approximation representing the organ of Corti cytoarchitecture. The model is fit to in vivo basilar membrane motion with one free parameter for the OHCs. The calculations predict that the total power output from the three rows of OHCs can be over three orders of magnitude greater than the acoustic input power at 10 dB sound pressure level (SPL). While previous work shows that the power gain, or the negative damping, diminishes with intensity, we show explicitly based on our model that OHC power output increases and saturates with SPL. The total OHC power output is about 2 pW at 80 dB SPL, with a maximum of about 10 fW per OHC.

  14. Single-transverse-mode near-IR superluminescent diodes with cw output power up to 100 mW

    Energy Technology Data Exchange (ETDEWEB)

    Andreeva, E V; Il' chenko, S N; Kostin, Yu O [Superlum Diodes Ltd., Moscow (Russian Federation); Yakubovich, S D [Moscow State Institute of Radio-Engineering, Electronics and Automation (Technical University), Moscow (Russian Federation)

    2014-10-29

    A series of light-emitting modules based on single-mode quantum-well superluminescent diodes with centre emission wavelengths of about 790, 840, 960 and 1060 nm and a cw output power up to 100 mW in free space is developed. A sufficiently long service life of these devices is demonstrated. (lasers)

  15. Single-transverse-mode near-IR superluminescent diodes with cw output power up to 100 mW

    International Nuclear Information System (INIS)

    Andreeva, E V; Il'chenko, S N; Kostin, Yu O; Yakubovich, S D

    2014-01-01

    A series of light-emitting modules based on single-mode quantum-well superluminescent diodes with centre emission wavelengths of about 790, 840, 960 and 1060 nm and a cw output power up to 100 mW in free space is developed. A sufficiently long service life of these devices is demonstrated. (lasers)

  16. Development of prediction models for radioactive caesium distribution within the 80-km radius of the Fukushima Daiichi nuclear power plant

    International Nuclear Information System (INIS)

    Kinase, Sakae; Sato, Satoshi; Saito, Kimiaki; Takahashi, Tomoyuki; Sakamoto, Ryuichi

    2014-01-01

    Preliminary prediction models have been studied for the radioactive caesium distribution within the 80-km radius of the Fukushima Daiichi nuclear power plant. The models were represented by exponential functions using ecological half-life of radioactive caesium in the environment. The ecological half-lives were derived from the changes in ambient dose equivalent rates through vehicle-borne surveys. It was found that the ecological half-lives of radioactive caesium were not constant within the 80-km radius of the Fukushima Daiichi nuclear power plant. The ecological half-life of radioactive caesium in forest areas was found to be much larger than that in urban and water areas. (authors)

  17. Scyntygrafia kości w diagnostyce reumatoidalnego zapalenia stawów

    Directory of Open Access Journals (Sweden)

    Witold Tłustochowicz

    2010-04-01

    Full Text Available Celem pracy była ocena przydatności trójfazowej dynamicznejscyntygrafii kości w diagnostyce reumatoidalnego zapalenia stawów.Badaniem objęto 39 chorych hospitalizowanych i diagnozowanychz powodu dolegliwości stawowych. Przeprowadzono diagnostykęobejmującą: badanie podmiotowe, przedmiotowe, badania laboratoryjneoraz obrazowe, w tym trójfazową scyntygrafię kości z użyciemtechnetu 99m. Scyntygraficzne cechy zapalenia stawówstwierdzano, gdy obserwowano wzmożone gromadzenie znacznikawe wszystkich trzech fazach badania.Po ukończeniu diagnostyki rozpoznano u 13 chorych wczesne reumatoidalnezapalenie stawów, u 4 reumatoidalne zapalenie stawów(łącznie 17 pacjentów, a u 1 niezróżnicowane zapalenie stawów.Scyntygrafia kości wykazała cechy zapalenia stawów u 13spośród nich (72,2%, u 4 osób (22,2% wzmożone gromadzeniestwierdzono tylko w fazie statycznej, a u 1 pacjenta (5,6% uzyskanoprawidłowy wynik badania. U 21 chorych wykluczono chorobęzapalną stawów (u 19 rozpoznano fibromialgię, u 2 chorobęzwyrodnieniową. W grupie bez zapalenia stawów u 14 pacjentów(66,6% nie stwierdzono istotnych nieprawidłowości w obraziescyntygraficznym, u 6 (28,6% występowało wzmożone gromadzenieznacznika w badaniu statycznym, a u 1 chorego (4,8% opisanoscyntygraficzne cechy zapalenia stawów.Wbadanej grupie czułość scyntygrafii dynamicznej kości w wykrywaniuzapalenia stawów wynosiła 72,2% (95% CI: 57,5–76,8, a swoistość 95,2% (95% CI: 82,8–99,1. Dodatni wynik badaniadynamicznego wskazuje z dużym prawdopodobieństwem naobecność zapalenia stawów [PPV 92,9% (95% CI: 74,2–98,7].Mniej wiarygodny był ujemny wynik badania [NPV 80% (95% CI:69,5–83,3]. Wyniki niniejszej pracy wskazują, że trójfazowa scyntygrafia dynamicznakości może mieć zastosowanie w diagnostyce reumatoidalnegozapalenia stawów.

  18. Performance of 100-W HVM LPP-EUV source

    Science.gov (United States)

    Mizoguchi, Hakaru; Nakarai, Hiroaki; Abe, Tamotsu; Nowak, Krzysztof M.; Kawasuji, Yasufumi; Tanaka, Hiroshi; Watanabe, Yukio; Hori, Tsukasa; Kodama, Takeshi; Shiraishi, Yutaka; Yanagida, Tatsuya; Soumagne, Georg; Yamada, Tsuyoshi; Yamazaki, Taku; Okazaki, Shinji; Saitou, Takashi

    2015-08-01

    At Gigaphoton Inc., we have developed unique and original technologies for a carbon dioxide laser-produced tin plasma extreme ultraviolet (CO2-Sn-LPP EUV) light source, which is the most promising solution for high-power high-volume manufacturing (HVM) EUV lithography at 13.5 nm. Our unique technologies include the combination of a pulsed CO2 laser with Sn droplets, the application of dual-wavelength laser pulses for Sn droplet conditioning, and subsequent EUV generation and magnetic field mitigation. Theoretical and experimental data have clearly shown the advantage of our proposed strategy. Currently, we are developing the first HVM light source, `GL200E'. This HVM light source will provide 250-W EUV power based on a 20-kW level pulsed CO2 laser. The preparation of a high average-power CO2 laser (more than 20 kW output power) has been completed in cooperation with Mitsubishi Electric Corporation. Recently, we achieved 140 W at 50 kHz and 50% duty cycle operation as well as 2 h of operation at 100 W of power level. Further improvements are ongoing. We will report the latest status and the challenge to reach stable system operation of more than 100 W at about 4% conversion efficiency with 20-μm droplets and magnetic mitigation.

  19. S-band low noise amplifier and 40 kW high power amplifier subsystems of Japanese Deep Space Earth Station

    Science.gov (United States)

    Honma, K.; Handa, K.; Akinaga, W.; Doi, M.; Matsuzaki, O.

    This paper describes the design and the performance of the S-band low noise amplifier and the S-band high power amplifier that have been developed for the Usuda Deep Space Station of the Institute of Space and Astronautical Science (ISAS), Japan. The S-band low noise amplifier consists of a helium gas-cooled parametric amplifier followed by three-stage FET amplifiers and has a noise temperature of 8 K. The high power amplifier is composed of two 28 kW klystrons, capable of transmitting 40 kW continuously when two klystrons are combined. Both subsystems are operating quite satisfactorily in the tracking of Sakigake and Suisei, the Japanese interplanetary probes for Halley's comet exploration, launched by ISAS in 1985.

  20. Test Results of a 200 W Class Hall Thruster

    Science.gov (United States)

    Jacobson, David; Jankovsky, Robert S.

    1999-01-01

    The performance of a 200 W class Hall thruster was evaluated. Performance measurements were taken at power levels between 90 W and 250 W. At the nominal 200 W design point, the measured thrust was 11.3 mN. and the specific impulse was 1170 s excluding cathode flow in the calculation. A laboratory model 3 mm diameter hollow cathode was used for all testing. The engine was operated on laboratory power supplies in addition to a breadboard power processing unit fabricated from commercially available DC to DC converters.

  1. Parylene-based electret power generators

    International Nuclear Information System (INIS)

    Lo, Hsi-wen; Tai, Yu-Chong

    2008-01-01

    An electret power generator is developed using a new electret made of a charged parylene HT® thin-film polymer. Here, parylene HT® is a room-temperature chemical-vapor-deposited thin-film polymer that is MEMS and CMOS compatible. With corona charge implantation, the surface charge density of parylene HT® is measured as high as 3.69 mC m −2 . Moreover, it is found that, with annealing at 400 °C for 1 h before charge implantation, both the long-term stability and the high-temperature reliability of the electret are improved. For the generator, a new design of the stator/rotor is also developed. The new micro electret generator does not require any sophisticated gap-controlling structure such as tethers. With the conformal coating capability of parylene HT®, it is also feasible to have the electret on the rotors, which is made of either a piece of metal or an insulator. The maximum power output, 17.98 µW, is obtained at 50 Hz with an external load of 80 MΩ. For low frequencies, the generator can harvest 7.7 µW at 10 Hz and 8.23 µW at 20 Hz

  2. The three-dimensional particle-in-cell simulation analysis of cavity of high power subterahertz pulsed gyrotron

    International Nuclear Information System (INIS)

    Ito, Koyu; Jiang, Weihua

    2013-01-01

    High power sub-terahertz pulsed gyrotrons for Collective Thomson Scattering (CTS) diagnostics of fusion plasmas are being developed. The typical target parameters are: output power of 100-200 kW, operation frequency of 300 GHz, and pulsed length > 10 us. In order to support experimental development, numerical simulations were carried out by using Particle-In-Cell (PIC) code MAGIC. The oscillation mode of the electromagnetic radiation was selected as TE_1_5_,_2, for which the beam parameters and cavity dimensions were determined accordingly. The simulation results have showed maximum power of 144 kW at oscillation frequency of 292.80 GHz, with oscillation efficiency of 22.15%. (author)

  3. Super-low-frequency wireless power transfer with lightweight coils for passing through a stainless steel plate

    Science.gov (United States)

    Ishida, Hiroki; Kyoden, Tomoaki; Furukawa, Hiroto

    2018-03-01

    To achieve wireless power transfer (WPT) through a stainless-steel plate, a super-low frequency (SLF) was used as a resonance frequency. In our previous study of SLF-WPT, heavy coils were prepared. In this study, we designed lightweight coils using a WPT simulator that we developed previously. As a result, the weight was reduced to 1.69 kg from 11.9 kg, the previous coil weight. At a resonance frequency of 400 Hz, the transmission efficiency and output power of advanced SLF-WPT reached 91% and 426 W, respectively, over a transmission distance of 30 mm. Furthermore, 80% efficiency and 317 W output were achieved when transmitting power through a 1 mm-thick stainless-steel plate. This performance is much better than that in previous reports. We show using both calculations and experimental results that a power-to-weight ratio of 252 W/kg is possible even when using a 400 Hz power supply frequency.

  4. PROPER MOTIONS OF THE OUTER KNOTS OF THE HH 80/81/80N RADIO-JET

    Energy Technology Data Exchange (ETDEWEB)

    Masqué, Josep M.; Rodriguez, Luis F.; Carrasco-González, Carlos [Instituto de Radioastronomía y Astrofísica, Universidad Nacional Autónoma de México, Morelia 58089, México (Mexico); Araudo, Anabella [University of Oxford, Astrophysics, Keble Road, Oxford OX1 3RH (United Kingdom); Estalella, Robert [Departament d’Astronomia i Meteorologia and Institut de Ciències del Cosmos (IEEC-UB), Universitat de Barcelona, Martí i Franquès 1, E-08028 Barcelona, Catalunya (Spain); Anglada, Guillem; Osorio, Mayra [Instituto de Astrofísica de Andalucía (CSIC), Apartado 3004, E-18080 Granada (Spain); Girart, Josep M. [Institut de Ciències de l’Espai (CSIC-IEEC), Campus UAB, Carrer de Can Magrans, S/N, E-08193 Cerdanyola del Vallès, Catalunya (Spain)

    2015-11-20

    The radio-knots of the Herbig–Haro (HH) 80/81/80N jet extend from the HH 80 object to the recently discovered Source 34 and has a total projected jet size of 10.3 pc, constituting the largest collimated radio-jet system known so far. It is powered by the bright infrared source IRAS 18162−2048 associated with a massive young stellar object. We report 6 cm JVLA observations that, compared with previous 6 cm VLA observations carried out in 1989, allow us to derive proper motions of the HH 80, HH 81, and HH 80N radio knots located about 2.5 pc away in projection from the powering source. For the first time, we measure proper motions of the optically obscured HH 80N object providing evidence that this knot, along with HH 81 and HH 80 are associated with the same radio-jet. We also confirm the presence of Source 34, located further north of HH 80N, previously proposed to belong to the jet.We derived that the tangential velocity of HH 80N is 260 km s{sup −1} and has a direction in agreement with the expected direction of a ballistic precessing jet. The HH 80 and HH 81 objects have tangential velocities of 350 and 220 km s{sup −1}, respectively, but their directions are somewhat deviated from the expected jet path. The velocities of the HH objects studied in this work are significantly lower than those derived for the radio knots of the jet close to the powering source (600–1400 km s{sup −1}) suggesting that the jet is slowing down due to a strong interaction with the ambient medium. As a result, since HH 80 and HH 81 are located near the edge of the cloud, the inhomogeneous and low density medium may contribute to skew the direction of their determined proper motions. The HH 80 and HH 80N emission at 6 cm is, at least in part, probably synchrotron radiation produced by relativistic electrons in a magnetic field of 1 mG. If these electrons are accelerated in a reverse adiabatic shock, we estimate a jet total density of ≲1000 cm{sup −3}. All of these

  5. Analysis and evaluation of the power amplifier device

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y. K.; Ryu, J. W. [Kongju National University, Gongju (Korea, Republic of)

    2011-11-15

    We developed a master oscillator power amplifier (MOPA) type fiber amplifier for the separation of the Ca-48 isotope by using a fiber laser. The ytterbium (Yb)-doped end-capped rod-type photonic crystal fiber (PCF) was used as a gain medium of MOPA amplifier. The PCFs used in our experiments were a 56-cm and an 81-cm rod-type end-capped Yb-doped double-clad PM fibers 'DC-285/100-PM-Yb-Rod', with a 100-{mu}m core (NA 0.02) and a 285-{mu}m cladding (NA 0.6) fabricated by NKT Photonics. The mode field diameter (MFD) of the rod-type PCF was 75-{mu}m, and an absorption efficiency of 30 dB/m at 976 nm and a low NA 0.02 helped to sustain the excellent lasing beam quality. We obtained an output power of 112 W at a pump power of 380 W with a repetition rate of 150 kHz. The measured pulse width was 13 ns at 150 kHz, 1056 nm. The laser beam quality shows a single mode amplification characteristics with a beam quality factor values of M2 are 2 -3. The PCF launching efficiency reached a maximum value of 86.7% with an average efficiencies of above 80%. At a pump power of 250 W and seed power input of 4 W, the CW PCF amplifier was found to generate average output powers of 138 W, 110 W, and 82 W at 1056-nm, 1070-nm, and 1089-nm wavelengths, respectively. The amplified PCF output beam had a line width of 70 MHz full width at half maximum (FWHM). These PCF amplified beams had good beam qualities with M2values of less than 1.8 at all three wavelengths. The gain saturation seed input power in the 81-cm PCF was found to be {approx}6 W at 1056 nm. The temperature of the PCF core reached over 230 .deg. C at the pumping section of the PCF. The temperatures of the end-cap heads on both the pumping and the output end-cap sides were 81.4 .deg. C and 35.7 .deg. C, respectively. The PCF amplifier maintained good polarization mode characteristics with an average DOP of over 87%. The slight decrease in the DOP oat output powers over 170 W output power may have been caused by a

  6. Measurement of the W Mass and Width in $e^{+}e^{-}$ Collisions at 183 GeV

    CERN Document Server

    Abbiendi, G; Alexander, Gideon; Allison, J; Altekamp, N; Anderson, K J; Anderson, S; Arcelli, S; Asai, S; Ashby, S F; Axen, D A; Azuelos, Georges; Ball, A H; Barberio, E; Barlow, R J; Bartoldus, R; Batley, J Richard; Baumann, S; Bechtluft, J; Behnke, T; Bell, K W; Bella, G; Bellerive, A; Bentvelsen, Stanislaus Cornelius Maria; Bethke, Siegfried; Betts, S; Biebel, O; Biguzzi, A; Bird, S D; Blobel, Volker; Bloodworth, Ian J; Bock, P; Böhme, J; Bonacorsi, D; Boutemeur, M; Braibant, S; Bright-Thomas, P G; Brigliadori, L; Brown, R M; Burckhart, Helfried J; Capiluppi, P; Carnegie, R K; Carter, A A; Carter, J R; Chang, C Y; Charlton, D G; Chrisman, D; Ciocca, C; Clarke, P E L; Clay, E; Cohen, I; Conboy, J E; Cooke, O C; Couyoumtzelis, C; Coxe, R L; Cuffiani, M; Dado, S; Dallavalle, G M; Davis, R; De Jong, S; de Roeck, A; Dervan, P J; Desch, Klaus; Dienes, B; Dixit, M S; Dubbert, J; Duchovni, E; Duckeck, G; Duerdoth, I P; Eatough, D; Estabrooks, P G; Etzion, E; Fabbri, Franco Luigi; Fanti, M; Faust, A A; Fiedler, F; Fierro, M; Fleck, I; Folman, R; Fürtjes, A; Futyan, D I; Gagnon, P; Gary, J W; Gascon, J; Gascon-Shotkin, S M; Gaycken, G; Geich-Gimbel, C; Giacomelli, G; Giacomelli, P; Gibson, V; Gibson, W R; Gingrich, D M; Glenzinski, D A; Goldberg, J; Gorn, W; Grandi, C; Graham, K; Gross, E; Grunhaus, Jacob; Gruwé, M; Hanson, G G; Hansroul, M; Hapke, M; Harder, K; Harel, A; Hargrove, C K; Hartmann, C; Hauschild, M; Hawkes, C M; Hawkings, R; Hemingway, Richard J; Herndon, M; Herten, G; Heuer, R D; Hildreth, M D; Hill, J C; Hobson, P R; Hoch, M; Höcker, Andreas; Hoffman, K; Homer, R James; Honma, A K; Horváth, D; Hossain, K R; Howard, R; Hüntemeyer, P; Igo-Kemenes, P; Imrie, D C; Ishii, K; Jacob, F R; Jawahery, A; Jeremie, H; Jimack, Martin Paul; Jones, C R; Jovanovic, P; Junk, T R; Karlen, D A; Kartvelishvili, V G; Kawagoe, K; Kawamoto, T; Kayal, P I; Keeler, Richard K; Kellogg, R G; Kennedy, B W; Kim, D H; Klier, A; Kluth, S; Kobayashi, T; Kobel, M; Koetke, D S; Kokott, T P; Kolrep, M; Komamiya, S; Kowalewski, R V; Kress, T; Krieger, P; Von Krogh, J; Kühl, T; Kyberd, P; Lafferty, G D; Landsman, Hagar Yaël; Lanske, D; Lauber, J; Lautenschlager, S R; Lawson, I; Layter, J G; Lazic, D; Lee, A M; Lellouch, Daniel; Letts, J; Levinson, L; Liebisch, R; List, B; Littlewood, C; Lloyd, A W; Lloyd, S L; Loebinger, F K; Long, G D; Losty, Michael J; Ludwig, J; Liu, D; Macchiolo, A; MacPherson, A L; Mader, W F; Mannelli, M; Marcellini, S; Markopoulos, C; Martin, A J; Martin, J P; Martínez, G; Mashimo, T; Mättig, P; McDonald, W J; McKenna, J A; McKigney, E A; McMahon, T J; McPherson, R A; Meijers, F; Menke, S; Merritt, F S; Mes, H; Meyer, J; Michelini, Aldo; Mihara, S; Mikenberg, G; Miller, D J; Mir, R; Mohr, W; Montanari, A; Mori, T; Nagai, K; Nakamura, I; Neal, H A; Nellen, B; Nisius, R; O'Neale, S W; Oakham, F G; Odorici, F; Ögren, H O; Oreglia, M J; Orito, S; Pálinkás, J; Pásztor, G; Pater, J R; Patrick, G N; Patt, J; Pérez-Ochoa, R; Petzold, S; Pfeifenschneider, P; Pilcher, J E; Pinfold, James L; Plane, D E; Poffenberger, P R; Polok, J; Przybycien, M B; Rembser, C; Rick, Hartmut; Robertson, S; Robins, S A; Rodning, N L; Roney, J M; Roscoe, K; Rossi, A M; Rozen, Y; Runge, K; Runólfsson, O; Rust, D R; Sachs, K; Saeki, T; Sahr, O; Sang, W M; Sarkisyan-Grinbaum, E; Sbarra, C; Schaile, A D; Schaile, O; Scharf, F; Scharff-Hansen, P; Schieck, J; Schmitt, B; Schmitt, S; Schöning, A; Schröder, M; Schumacher, M; Schwick, C; Scott, W G; Seuster, R; Shears, T G; Shen, B C; Shepherd-Themistocleous, C H; Sherwood, P; Siroli, G P; Sittler, A; Skuja, A; Smith, A M; Snow, G A; Sobie, Randall J; Söldner-Rembold, S; Spagnolo, S; Sproston, M; Stahl, A; Stephens, K; Steuerer, J; Stoll, K; Strom, D; Ströhmer, R; Surrow, B; Talbot, S D; Tanaka, S; Taras, P; Tarem, S; Teuscher, R; Thiergen, M; Thomas, J; Thomson, M A; Von Törne, E; Torrence, E; Towers, S; Trigger, I; Trócsányi, Z L; Tsur, E; Turcot, A S; Turner-Watson, M F; Ueda, I; Van Kooten, R; Vannerem, P; Verzocchi, M; Voss, H; Wäckerle, F; Wagner, A; Ward, C P; Ward, D R; Watkins, P M; Watson, A T; Watson, N K; Wells, P S; Wermes, N; White, J S; Wilson, G W; Wilson, J A; Wyatt, T R; Yamashita, S; Yekutieli, G; Zacek, V; Zer-Zion, D

    1999-01-01

    Using a data sample of 57 pb-1 recorded at a centre-of-mass energy of 183 GeV with the Opal detector at LEP, 282 W+W- -> qqqq and 300 W+W- -> qqlnu candidate events are used to obtain a measurement of the mass of the W boson, W_W = 80.39 +- 0.13(stat.) +- 0.05(syst.) GeV assuming the Standard Model relation between M_W and Gam_W. A second fit provides a direct measure of the width of the W boson and gives Gam_W = 1.96 +- 0.34(stat.) +- 0.20(syst.) GeV. These results are combined with previous OPAL results to obtain M_W = 80.38 +- 0.12(stat.) +- 0.05(syst.) GeV and Gam_W = 1.84 +- 0.32(stat.) +- 0.20(syst.) GeV.

  7. 16 W output power by high-efficient spectral beam combining of DBR-tapered diode lasers

    DEFF Research Database (Denmark)

    Müller, André; Vijayakumar, Deepak; Jensen, Ole Bjarlin

    2011-01-01

    output power achieved by spectral beam combining of two single element tapered diode lasers. Since spectral beam combining does not affect beam propagation parameters, M2-values of 1.8 (fast axis) and 3.3 (slow axis) match the M2- values of the laser with lowest spatial coherence. The principle......Up to 16 W output power has been obtained using spectral beam combining of two 1063 nm DBR-tapered diode lasers. Using a reflecting volume Bragg grating, a combining efficiency as high as 93.7% is achieved, resulting in a single beam with high spatial coherence. The result represents the highest...... of spectral beam combining used in our experiments can be expanded to combine more than two tapered diode lasers and hence it is expected that the output power may be increased even further in the future....

  8. 16 W output power by high-efficient spectral beam combining of DBR-tapered diode lasers.

    Science.gov (United States)

    Müller, André; Vijayakumar, Deepak; Jensen, Ole Bjarlin; Hasler, Karl-Heinz; Sumpf, Bernd; Erbert, Götz; Andersen, Peter E; Petersen, Paul Michael

    2011-01-17

    Up to 16 W output power has been obtained using spectral beam combining of two 1063 nm DBR-tapered diode lasers. Using a reflecting volume Bragg grating, a combining efficiency as high as 93.7% is achieved, resulting in a single beam with high spatial coherence. The result represents the highest output power achieved by spectral beam combining of two single element tapered diode lasers. Since spectral beam combining does not affect beam propagation parameters, M2-values of 1.8 (fast axis) and 3.3 (slow axis) match the M2-values of the laser with lowest spatial coherence. The principle of spectral beam combining used in our experiments can be expanded to combine more than two tapered diode lasers and hence it is expected that the output power may be increased even further in the future.

  9. High power testing of the multiple-loop radio-frequency drive concept for the FMIT accelerator

    International Nuclear Information System (INIS)

    Fazio, M.V.; Patton, R.D.

    1984-04-01

    The Fusion Materials Irradiation Test (FMIT) accelerator requires several 600-kW rf systems to simultaneously supply rf power to a single accelerator tank. Each rf-system output must be carefully phase and amplitude controlled to achieve the proper system performance. Two 80-MHz, 600-kW rf amplifiers with phase- and amplitude-control systems have been tested into a single, high-Q resonant cavity. Experimental results are presented

  10. High-Power and High-Efficiency 1.3- µm Superluminescent Diode With Flat-Top and Ultrawide Emission Bandwidth

    KAUST Repository

    Khan, Mohammed Zahed Mustafa; Alhashim, Hala H.; Ng, Tien Khee; Ooi, Boon S.

    2015-01-01

    We report on a flat-top and ultrawide emission bandwidth of 125 nm from InGaAsP/InP multiple quantum-well (MQW) superluminescent diode with antireflection coated and tilted ridge-waveguide device configuration. A total output power in excess of 70 mW with an average power spectral density of 0.56 mW/nm and spectral ripple ≤ 1.2 ± 0.5 dB is measured from the device. Wall-plug efficiency and output power as high as 14% and 80 mW, respectively, is demonstrated from this batch of devices. We attribute the broad emission to the inherent inhomogeneity of the electron-heavy-hole (e-hh) and electron-light-hole (e-lh) recombination of the ground state and the first excited state of the MQWs and their simultaneous emission.

  11. High-Power and High-Efficiency 1.3- µm Superluminescent Diode With Flat-Top and Ultrawide Emission Bandwidth

    KAUST Repository

    Khan, Mohammed Zahed Mustafa

    2015-02-01

    We report on a flat-top and ultrawide emission bandwidth of 125 nm from InGaAsP/InP multiple quantum-well (MQW) superluminescent diode with antireflection coated and tilted ridge-waveguide device configuration. A total output power in excess of 70 mW with an average power spectral density of 0.56 mW/nm and spectral ripple ≤ 1.2 ± 0.5 dB is measured from the device. Wall-plug efficiency and output power as high as 14% and 80 mW, respectively, is demonstrated from this batch of devices. We attribute the broad emission to the inherent inhomogeneity of the electron-heavy-hole (e-hh) and electron-light-hole (e-lh) recombination of the ground state and the first excited state of the MQWs and their simultaneous emission.

  12. Pharmacokinetics of ketoprofen enantiomers following intravenous and oral administration to exercised Thoroughbred horses.

    Science.gov (United States)

    Knych, Heather K; Arthur, Rick M; Steinmetz, Stacy; McKemie, Dan S

    2016-01-01

    Ketoprofen (KTP) is currently only available as an injectable formulation for intravenous administration to horses. The primary goal of the study reported here was to characterize the pharmacokinetics of KTP, including determination of bioavailability following oral administration of the currently available injectable formulation as well as a paste formulation. KTP was administered intravenously and orally, and blood and urine samples were collected at various time points up to 96 h. KTP enantiomer concentrations were determined using LC–MS/MS, and pharmacokinetic analyses were performed. Mean ± standard error values for systemic clearance, steady state volume of distribution and terminal elimination half-life were 0.345 ± 0.033 [R(−) KTP] and 0.167 ± 0.016 [S(+) KTP] L/kg/h, 0.344 ± 0.044 [R(−) KTP] and 0.298 ± 0.025 [S(+) KTP] L/kg, and 2.49 ± 0.077 [R(−) KTP] and 2.86 ± 0.102 [S(+) KTP] h, respectively. Oral bioavailability was calculated as 69.5 ± 10.3% and 88.2 ± 15.9% for R(−) KTP and S(+) KTP, respectively, following administration of the injectable formulation and 53.0 ± 6.0 and 53.0 ± 16.0% for the R(−) KTP and S(+) KTP, respectively, following administration of KTP paste.

  13. A CMOS Low-Power Optical Front-End for 5 Gbps Applications

    Science.gov (United States)

    Zohoori, Soorena; Dolatshahi, Mehdi

    2018-01-01

    In this paper, a new low-power optical receiver front-end is proposed in 90 nm CMOS technology for 5 Gb/s AApplications. However, to improve the gain-bandwidth trade-off, the proposed Trans-Impedance Amplifier (TIA) uses an active modified inverter-based topology followed by a common-source amplifier, which uses active inductive peaking technique to enhance the frequency bandwidth in an increased gain level for a reasonable power consumption value. The proposed TIA is analyzed and simulated in HSPICE using 90 nm CMOS technology parameters. Simulation results show a 53.5dBΩ trans-impedance gain, 3.5 GHz frequency bandwidth, 16.8pA/√Hz input referred noise, and 1.28 mW of power consumption at 1V supply voltage. The Optical receiver is completed using three stages of differential limiting amplifiers (LAs), which provide 27 dB voltage gain while consume 3.1 mW of power. Finally, the whole optical receiver front-end consumes only 5.6 mW of power at 1 V supply and amplifies the input signal by 80 dB, while providing 3.7 GHz of frequency bandwidth. Finally, the simulation results indicate that the proposed optical receiver is a proper candidate to be used in a low-power 5 Gbps optical communication system.

  14. High power pulsed/microwave technologies for electron accelerators vis a vis 10MeV, 10kW electron LINAC for food irradiation at CAT

    International Nuclear Information System (INIS)

    Shrivastava, Purushottam; Mulchandani, J.; Mohania, P.; Baxy, D.; Wanmode, Y.; Hannurkar, P.R.

    2005-01-01

    Use of electron accelerators for irradiation of food items is gathering momentum in India. The various technologies for powering the electron LINAC were needed to be developed in the country due to embargo situations as well as reservations of the developers worldwide to share the information related to this development. Centre for Advanced Technology, CAT, Indore, is engaged in the development of particle accelerators for medical industrial and scientific applications. Amongst other electron accelerators developed in CAT, a 10MeV, 10kW LINAC for irradiation of food items has been commissioned and tested for full rated 10kW beam power. The high power pulsed microwave driver for the LINAC was designed, developed and commissioned with full indigenous efforts, and is right now operational at CAT. It consists of a 6MW, 25kW S-band pulsed klystron, 15MW peak power pulse modulator system for the klystron, microwave driver amplifier chain, stabilized generator, protection and control electronics, waveguide system to handle the high peak and average power, gun modulator electronics, grid electronics etc. The present paper highlights various technologies like the pulsed power systems and components, microwave circuits and systems etc. Also the performance results of the high power microwave driver for the 10MeV LINAC at CAT are discussed. Future strategies for developing the state of art technologies are highlighted. (author)

  15. Report on demonstrative research on photovoltaic power generation system in Myanmar

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    With an objective of installation and demonstrative operation in Myanmar of a power generation system combining a small-scale photovoltaic power generation system, a wind power generation system, and a diesel generator, research and development is being made under a six year plan starting in 1999 and ending in 2004. Comparative discussions were given on the installation location of the power generation system for the climatic conditions in Chaungthar and Letkhokekone, whereas the final decision was given on Chaungthar. This project plans installation of a photovoltaic power generation system of 80 kW, a wind power generation system of 40 kW, and a diesel generator of 60 kW. Power generation will start at 6 o'clock in the morning and continue to 11 o'clock at night every day, with a storage battery of 1,000 Ah and a stabilized load comprising of ice maker units to be installed. Observation of wind power and solar insolation is being continued with an aim of acquiring data over a period of one year or longer, whereas the data as have been forecasted are being acquired at the present. The diesel generator was manufactured in Japan, which has been arrived at the port of Yangon in February 2001, and installed at the site in Chaungthar in March. (NEDO)

  16. 47 CFR 80.965 - Reserve power supply.

    Science.gov (United States)

    2010-10-01

    ... conditions. When meeting this 2 hour requirement, such reserve power supply must be located on the bridge... radiotelephone must be a “reserve power supply” for the purposes of paragraphs (c), (d) and (e) of this section... meeting the requirements of paragraph (a) of this section as follows: (1) When the reserve power supply...

  17. 18 CFR 367.80 - Supervision and engineering.

    Science.gov (United States)

    2010-04-01

    ... engineering. 367.80 Section 367.80 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... ACT Operating Expense Instructions § 367.80 Supervision and engineering. (a) The supervision and engineering includible in the operating expense accounts must consist of the pay and expenses of...

  18. Tests to determine the release of short-lived fission products from UO2 fuel operating at linear powers of 45 and 60 kW/m

    International Nuclear Information System (INIS)

    Hastings, I.J.; Hunt, C.E.L.; Lipsett, J.J.; MacDonald, R.D.

    1985-09-01

    Experiments have been carried out using a 'sweep gas' technique to determine the behaviour of short-lived fission products within operating, intact UO 2 fuel elements. The Zircaloy-4-clad elements were 600 mm long and contained fuel of density 10.65 - 10.71 Mg/m 3 . A He-2% H 2 carrier gas swept gaseous or volatile fission products out of the operating fuel element past a gamma spectrometer for measurement. We outline our loop model and give full details of calculational procedures. In tests at linear powers of 45 (FIO-122) and 60 kW/m (FIO-124) to a maximum burnup of 80 MW.h/kg U, the species measured directly at the spectrometer during normal operation were generally the short-lived xenons and kryptons. Iodines were not observed during normal operation. The behaviour of I-133 and I-135 was deduced from the decay of Xe-133 and Xe-135 during reactor shutdowns. Plots of R/B (released/born) against λ (decay constant) or effective λ for all isotopes observed at 45 and 60 kW/m show that a line of slope -0.5, corresponding with diffusion kinetics, is a good fit to the measured xenon and krypton data. The inferred release of iodine fits the same line. From this we can extrapolate to an R/B for I-131 of about 5 x 10 -4 at 45 kW/m, and 3 x 10 -3 at 60 kW/m. Both tests were terminated by defects. Under defect conditions, R/B dependence on λ was about 0.6. I-131 release under defect conditions was 5 Ci and 60 mCi for FIO-122 and FI0-124, respectively. 22 refs

  19. Technology developments for ACIGA high power test facility for advanced interferometry

    Energy Technology Data Exchange (ETDEWEB)

    Barriga, P [School of Physics, University of Western Australia, Perth, WA 6009 (Australia); Barton, M [California Institute of Technology, LIGO Project, Pasadena, CA 91125 (United States); Blair, D G [School of Physics, University of Western Australia, Perth, WA 6009 (Australia)] [and others

    2005-05-21

    The High Optical Power Test Facility for Advanced Interferometry has been built by the Australian Consortium for Interferometric Gravitational Astronomy north of Perth in Western Australia. An 80 m suspended cavity has been prepared in collaboration with LIGO, where a set of experiments to test suspension control and thermal compensation will soon take place. Future experiments will investigate radiation pressure instabilities and optical spring effects in a high power optical cavity with {approx}200 kW circulating power. The facility combines research and development undertaken by all consortium members, whose latest results are presented.

  20. Technology developments for ACIGA high power test facility for advanced interferometry

    International Nuclear Information System (INIS)

    Barriga, P; Barton, M; Blair, D G

    2005-01-01

    The High Optical Power Test Facility for Advanced Interferometry has been built by the Australian Consortium for Interferometric Gravitational Astronomy north of Perth in Western Australia. An 80 m suspended cavity has been prepared in collaboration with LIGO, where a set of experiments to test suspension control and thermal compensation will soon take place. Future experiments will investigate radiation pressure instabilities and optical spring effects in a high power optical cavity with ∼200 kW circulating power. The facility combines research and development undertaken by all consortium members, whose latest results are presented

  1. Perpendicular eν mass from W decay

    International Nuclear Information System (INIS)

    Barger, V.; Martin, A.G.; Phillips, R.J.N.

    1983-01-01

    Properties of the perpendicular eν mass, defined in terms of transverse momenta p-vectorsub(T) by Msub(T)sup(2)(eν) = 2|p-vectorsub(eT)| |p-vectorsub(νT)| - 2p-vectorsub(eT).p-vectorsub(νT), that make it particularly well suited to W mass and width determinations are examined. An analytic expression for its distribution in W production and subsequent W → eν decay at p-barp colliders, accurate to order approximately equal to 1% is given. A maximum likelihood fit of this formula to the five UA1 events gives Msub(W) = 80.3 +- 3 6 GeV. (author)

  2. Efficient processing of CFRP with a picosecond laser with up to 1.4 kW average power

    Science.gov (United States)

    Onuseit, V.; Freitag, C.; Wiedenmann, M.; Weber, R.; Negel, J.-P.; Löscher, A.; Abdou Ahmed, M.; Graf, T.

    2015-03-01

    Laser processing of carbon fiber reinforce plastic (CFRP) is a very promising method to solve a lot of the challenges for large-volume production of lightweight constructions in automotive and airplane industries. However, the laser process is actual limited by two main issues. First the quality might be reduced due to thermal damage and second the high process energy needed for sublimation of the carbon fibers requires laser sources with high average power for productive processing. To achieve thermal damage of the CFRP of less than 10μm intensities above 108 W/cm² are needed. To reach these high intensities in the processing area ultra-short pulse laser systems are favored. Unfortunately the average power of commercially available laser systems is up to now in the range of several tens to a few hundred Watt. To sublimate the carbon fibers a large volume specific enthalpy of 85 J/mm³ is necessary. This means for example that cutting of 2 mm thick material with a kerf width of 0.2 mm with industry-typical 100 mm/sec requires several kilowatts of average power. At the IFSW a thin-disk multipass amplifier yielding a maximum average output power of 1100 W (300 kHz, 8 ps, 3.7 mJ) allowed for the first time to process CFRP at this average power and pulse energy level with picosecond pulse duration. With this unique laser system cutting of CFRP with a thickness of 2 mm an effective average cutting speed of 150 mm/sec with a thermal damage below 10μm was demonstrated.

  3. Measurement of the W mass at LEP

    CERN Document Server

    Przysiezniak, H

    2000-01-01

    The mass of the W boson is measured using W pair events collected with the ALEPH, DELPHI, L3 and OPAL detectors at LEP2. Three methods are used: the cross section method, the lepton energy spectrum method and the direct reconstruction method, where the latter is described more in detail. For data collected at E/sub cm/=161, 172 and 183 GeV, the following combined preliminary result is obtained: M/sub W//sup LEP/=80.37+or-0.08 GeV/c/sup 2/. (5 refs).

  4. Design report on the SSCL prototype 80 K Synchrotron Radiation Liner System

    International Nuclear Information System (INIS)

    Shu, Q.S.; Barts, T.; Chou, W.

    1993-09-01

    This report documents the effort to develop a viable design for an SSC prototype 80 K Synchrotron Radiation Liner System. This liner is designed to be tested in the Superconducting Super Collider Accelerator Systems String Test (ASST) facility. The liner is one method under consideration to minimize the presence of photodesorbed gases in the particle beam line vacuum environment. Secondly, the liner is aimed at improving the Collider cryogenic thermal efficiency which would allow a potential luminosity upgrade. The SSC Collider is the first proton superconducting accelerator designed to operate at an energy of 20 TeV (each beam) and a beam current of 72 mA. The Collider will produce a synchrotron power of 0.14 W/m and a total of 18 kW into 4.2 K for the two rings. This radiated power may trigger a serious impact of photodesorbed gases on the operational availability of the Collider. The interaction between beam particle and photodesorbed gases may greatly reduce the beam lifetime and the scattered beam power may lead to quenching of the superconducting magnets. Collider availability may be unacceptable if this concern is not properly addressed. The liner is one method under consideration to minimize the presence of photodesorbed gases in the particle beam line vacuum. Secondly, the liner is aimed improving the Collider's cryogenic thermal efficiency which would allow a potential luminosity upgrade. The ultimate goal is to require no more than one machine warm up per year for vacuum maintenance during operation of the SSC Collider

  5. Design report on the SSCL prototype 80 K Synchrotron Radiation Liner System

    Energy Technology Data Exchange (ETDEWEB)

    Shu, Q.S.; Barts, T.; Chou, W. [and others

    1993-09-01

    This report documents the effort to develop a viable design for an SSC prototype 80 K Synchrotron Radiation Liner System. This liner is designed to be tested in the Superconducting Super Collider Accelerator Systems String Test (ASST) facility. The liner is one method under consideration to minimize the presence of photodesorbed gases in the particle beam line vacuum environment. Secondly, the liner is aimed at improving the Collider cryogenic thermal efficiency which would allow a potential luminosity upgrade. The SSC Collider is the first proton superconducting accelerator designed to operate at an energy of 20 TeV (each beam) and a beam current of 72 mA. The Collider will produce a synchrotron power of 0.14 W/m and a total of 18 kW into 4.2 K for the two rings. This radiated power may trigger a serious impact of photodesorbed gases on the operational availability of the Collider. The interaction between beam particle and photodesorbed gases may greatly reduce the beam lifetime and the scattered beam power may lead to quenching of the superconducting magnets. Collider availability may be unacceptable if this concern is not properly addressed. The liner is one method under consideration to minimize the presence of photodesorbed gases in the particle beam line vacuum. Secondly, the liner is aimed improving the Collider`s cryogenic thermal efficiency which would allow a potential luminosity upgrade. The ultimate goal is to require no more than one machine warm up per year for vacuum maintenance during operation of the SSC Collider.

  6. Final Test of the W7-X Control Coils Power Supply and its Integration into the Overall Control Environment

    International Nuclear Information System (INIS)

    Fuellenbach, F.; Rummel, T.; Pingel, S.; Laqua, H.; Mueller, I.; Jauregi, E.

    2006-01-01

    In order to be able to vary the magnetic configuration of WENDELSTEIN 7-X (W7-X) at the plasma edge and allow sweeping of the power across the divertor target plates 10 '' control coils '' are installed inside the plasma vessel behind the baffle plates of the divertor. The coils are made of a hollow copper profile with eight turns each. The dimensions of the coils are 2,05 m x 0,35 m x 0,35 m with a three dimensional shape to fit into the narrow space between the baffles and the wall of the plasma vessel. Each of the ten coils is supplied by independent power supplies each providing bi-directionally a direct current of 2500 A with high accuracy and low ripple. To allow sweeping the power deposition from the plasma across the target plates the power supplies provide an alternating current of up to 625 A with frequencies up to 20 Hz which is synchronised between the ten supplies in order to maintain the symmetry of the magnetic field. The total output current of a power supply is a superposition of a direct current and an alternating current, where both parts have to be independently adjustable. JEMA, Spain provided the complete set of power supplies which are based on 10 independent four-quadrant power supplies with a link rectifier and includes a cooling water unit, a dedicated distribution and a central control and visualization system. All ten power supply units and auxiliary systems have meanwhile been installed and finally tested at the W7-X site in Greifswald. The paper focuses on the results of the final tests and measures to integrate the power supply system to the overall control system including the central PLC and PC's for experiment control, data acquisition- and security systems. (author)

  7. Theory "W": The Corporate Warrior.

    Science.gov (United States)

    Morris, David J., Jr.

    1986-01-01

    Describes power structure of corporations functioning under Theory W in which single leaders, in partnership with trusted followers, achieve corporate success. Basis of this industrial structure is attributed to social and developmental structures of prehistoric man and city states. Dimensions of W, X, Y, and Z theories are discussed. (MBR)

  8. Transparent conducting Al-doped ZnO thin films prepared by magnetron sputtering with dc and rf powers applied in combination

    International Nuclear Information System (INIS)

    Minami, Tadatsugu; Ohtani, Yuusuke; Miyata, Toshihiro; Kuboi, Takeshi

    2007-01-01

    A newly developed Al-doped ZnO (AZO) thin-film magnetron-sputtering deposition technique that decreases resistivity, improves resistivity distribution, and produces high-rate depositions has been demonstrated by dc magnetron-sputtering depositions that incorporate rf power (dc+rf-MS), either with or without the introduction of H 2 gas into the deposition chamber. The dc+rf-MS preparations were carried out in a pure Ar or an Ar+H 2 (0%-2%) gas atmosphere at a pressure of 0.4 Pa by adding a rf component (13.56 MHz) to a constant dc power of 80 W. The deposition rate in a dc+rf-MS deposition incorporating a rf power of 150 W was approximately 62 nm/min, an increase from the approximately 35 nm/min observed in dc magnetron sputtering with a dc power of 80 W. A resistivity as low as 3x10 -4 Ω cm and an improved resistivity distribution could be obtained in AZO thin films deposited on substrates at a low temperature of 150 deg. C by dc+rf-MS with the introduction of hydrogen gas with a content of 1.5%. This article describes the effects of adding a rf power component (i.e., dc+rf-MS deposition) as well as introducing H 2 gas into dc magnetron-sputtering preparations of transparent conducting AZO thin films

  9. 53 W average power few-cycle fiber laser system generating soft x rays up to the water window.

    Science.gov (United States)

    Rothhardt, Jan; Hädrich, Steffen; Klenke, Arno; Demmler, Stefan; Hoffmann, Armin; Gotschall, Thomas; Eidam, Tino; Krebs, Manuel; Limpert, Jens; Tünnermann, Andreas

    2014-09-01

    We report on a few-cycle laser system delivering sub-8-fs pulses with 353 μJ pulse energy and 25 GW of peak power at up to 150 kHz repetition rate. The corresponding average output power is as high as 53 W, which represents the highest average power obtained from any few-cycle laser architecture so far. The combination of both high average and high peak power provides unique opportunities for applications. We demonstrate high harmonic generation up to the water window and record-high photon flux in the soft x-ray spectral region. This tabletop source of high-photon flux soft x rays will, for example, enable coherent diffractive imaging with sub-10-nm resolution in the near future.

  10. DESIGN AND DEVELOPMENT OF A 1/3 SCALE VERTICAL AXIS WIND TURBINE FOR ELECTRICAL POWER GENERATION

    Directory of Open Access Journals (Sweden)

    Altab Md. Hossain

    2007-12-01

    Full Text Available This research describes the electrical power generation in Malaysia by the measurement of wind velocity acting on the wind turbine technology. The primary purpose of the measurement over the 1/3 scaled prototype vertical axis wind turbine for the wind velocity is to predict the performance of full scaled H-type vertical axis wind turbine. The electrical power produced by the wind turbine is influenced by its two major part, wind power and belt power transmission system. The blade and the drag area system are used to determine the powers of the wind that can be converted into electric power as well as the belt power transmission system. In this study both wind power and belt power transmission system has been considered. A set of blade and drag devices have been designed for the 1/3 scaled wind turbine at the Thermal Laboratory of Faculty of Engineering, Universiti Industri Selangor (UNISEL. Test has been carried out on the wind turbine with the different wind velocities of 5.89 m/s, 6.08 m/s and 7.02 m/s. From the experiment, the wind power has been calculated as 132.19 W, 145.40 W and 223.80 W. The maximum wind power is considered in the present study.

  11. DESIGN AND DEVELOPMENT OF A 1/3 SCALE VERTICAL AXIS WIND TURBINE FOR ELECTRICAL POWER GENERATION

    Directory of Open Access Journals (Sweden)

    Altab Hossain

    2007-01-01

    Full Text Available This research describes the electrical power generation in Malaysia by the measurement of wind velocity acting on the wind turbine technology. The primary purpose of the measurement over the 1/3 scaled prototype vertical axis wind turbine for the wind velocity is to predict the performance of full scaled H-type vertical axis wind turbine. The electrical power produced by the wind turbine is influenced by its two major part, wind power and belt power transmission system. The blade and the drag area system are used to determine the powers of the wind that can be converted into electric power as well as the belt power transmission system. In this study both wind power and belt power transmission system has been considered. A set of blade and drag devices have been designed for the 1/3 scaled wind turbine at the Thermal Laboratory of Faculty of Engineering, Universiti Industri Selangor (UNISEL. Test has been carried out on the wind turbine with the different wind velocities of 5.89 m/s, 6.08 m/s and 7.02 m/s. From the experiment, the wind power has been calculated as 132.19 W, 145.40 W and 223.80 W. The maximum wind power is considered in the present study.

  12. Experimental Investigation from the Operation of a 2 kW Brayton Power Conversion Unit and a Xenon Ion Thruster

    Science.gov (United States)

    Hervol, David; Mason, Lee; Birchenough, Art; Pinero, Luis

    2004-01-01

    A 2kW Brayton Power Conversion Unit (PCU) and a xenon ion thruster were integrated with a Power Management and Distribution (PMAD) system as part of a Nuclear Electric Propulsion (NEP) Testbed at NASA's Glenn Research Center. Brayton Converters and ion thrusters are potential candidates for use on future high power NEP mission such as the proposed Jupiter Icy Moons Orbiter (JIMO). The use of a existing lower power test hardware provided a cost effective means to investigate the critical electrical interface between the power conversion system and the propulsion system. The testing successfully demonstrated compatible electrical operations between the converter and the thruster, including end-to-end electric power throughput, high efficiency AC to DC conversion, and thruster recycle fault protection. The details of this demonstration are reported herein.

  13. Efficient generation of 3.5W laser light at 515nm by frequency doubling a single-frequency high power DBR tapered diode laser

    DEFF Research Database (Denmark)

    Jensen, Ole Bjarlin; Hansen, Anders Kragh; Müller, André

    2017-01-01

    More than 3.5 W of green light at 515 nm is generated by frequency doubling a single-frequency high power DBR tapered diode laser. The frequency doubling is performed in a cascade of PPMgLN and PPMgSLT crystals in order to reach high power and avoid thermal effects present in PPMgLN at high power...

  14. Status of system 80+ design certification

    International Nuclear Information System (INIS)

    Matzie, R.A.

    1992-01-01

    This paper reports that 1991 was a year of great progress in the design certification process for ABB Combustion Engineering Nuclear Power's 1300 MWe evolutionary advanced light water reactor (ALWR) plant, System 80+. As the next generation of nuclear power plants move toward final design approval by the U.S. Nuclear Regulatory Commission (NRC), elements of the design process that emphasize operation and maintenance have become the focus. For System 80+, licensing under the new design certification process is now concentrated on operational support, human engineering, plant layout, and computer-aided engineering

  15. Electric power supply in Sweden 1979/80

    International Nuclear Information System (INIS)

    1981-01-01

    Generation, transmission and consumption of electricity for the year 1979/80 in Sweden are review in this report. The net supply of electricity in TWh was 60.2 from hydro, 20.1 from nuclear, 12.1 from fossil thermal and 1.4 imported. Detailed statistics are given for both consumption and generation. (L.E.)

  16. Controller for the Machine-Side Power Converter of a 2kW Switched Reluctance Motor; Controlador del Convertidor Electronico de Potencia Lado Maquina de un Motor de Reluctancia Variable de 2kW

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez, C.

    2006-07-01

    The ACE2 project deals with the development of a kynetic energy storage (KES) system for power peak shaving in high speed railway substations. This KES system consists in a double power converter which drives a switched reluctance machine (SRM) along with a flywheel operating in a wide speed range. This document presents from a technical point of view the features of the controller for the machine-side power converter of a 2kW SRM prototype. Hardware and software issues are treated in detail. (Author)

  17. Controller for the Machine-Side Power Converter of a 2kW Switched Reluctance Motor; Controlador del Convertidor Electronico de Potencia Lado Red de un Motor de Reluctancia Variable de 2kW

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez, C.

    2006-12-19

    The ACE2 project deals with the development of a kynetic energy storage (KES) system for power peak shaving in high speed railway substations. This KES system consists in a double power converter which drives a switched reluctance machine (SRM) along with a flywheel operating in a wide speed range. This document presents from a technical point of view the features of the controller for the machine-side power converter of a 2kW SRM prototype. Hardware and software issues are treated in detail. (Author)

  18. Image compression using the W-transform

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, W.D. Jr. [Argonne National Lab., IL (United States). Mathematics and Computer Science Div.

    1995-12-31

    The authors present the W-transform for a multiresolution signal decomposition. One of the differences between the wavelet transform and W-transform is that the W-transform leads to a nonorthogonal signal decomposition. Another difference between the two is the manner in which the W-transform handles the endpoints (boundaries) of the signal. This approach does not restrict the length of the signal to be a power of two. Furthermore, it does not call for the extension of the signal thus, the W-transform is a convenient tool for image compression. They present the basic theory behind the W-transform and include experimental simulations to demonstrate its capabilities.

  19. Efficient diode-pumped Tm:KYW 1.9-μm microchip laser with 1 W cw output power.

    Science.gov (United States)

    Gaponenko, Maxim; Kuleshov, Nikolay; Südmeyer, Thomas

    2014-05-19

    We report on a diode-pumped Tm:KYW microchip laser generating 1 W continuous-wave output power. The laser operates at a wavelength of 1.94 μm in the fundamental TEM(00) mode with 71% slope efficiency relative to the absorbed pump radiation and 59% slope efficiency relative to the incident pump radiation. The optical-to-optical laser efficiency is 43%.

  20. Efficient diode-pumped Tm:KYW 1.9-μm microchip laser with 1 W cw output power

    OpenAIRE

    Gaponenko, M. S.; Kuleshov, N. V.; Südmeyer, T.

    2014-01-01

    We report on a diode-pumped Tm:KYW microchip laser generating 1 W continuous-wave output power. The laser operates at a wavelength of 1.94 μm in the fundamental TEM00 mode with 71% slope efficiency relative to the absorbed pump radiation and 59% slope efficiency relative to the incident pump radiation. The optical-to-optical laser efficiency is 43%.

  1. Enhanced saturation magnetization of Fe3Si nanodot-embedded Fe80Si17Nb3 flexible film for efficient wireless power transfer

    International Nuclear Information System (INIS)

    Pai, Yi-Hao; Yan, Zih-Yu; Fu, Ping-Hao

    2013-01-01

    An efficient magnetically coupled resonance response is performed using an iron silicide-based nanostructured magnetoelectric material with high saturation magnetization for the wireless charging of battery-powered consumer electronics. With 500 °C annealing, the self-assembled Fe 3 Si nanodots buried in the Fe 80 Si 17 Nb 3 host matrix with (220) lattice spacing of 1.99 Å corresponding to a volume density of 8.96 × 10 16 cm 3 , can be obtained and a maximum saturation magnetization of 244 emu g −1 achieved. The return loss of the antenna will be tuned to match the designed frequency with greater attenuated intensity (−0.39 dB) and a relatively narrow bandwidth (6 kHz) when the Fe 3 Si nanodot-embedded Fe 80 Si 17 Nb 3 sample is placed in a WiTricity system. An efficient wireless power transfer can be created and improved from 47.5% to 97.3%. The associated coil and loop antenna resonators are significantly readjusted to match the power transfer by putting this nanostructured magnetoelectric material in a WiTricity system. - Highlights: • The saturation magnetization is effective enhancement in the presence of Fe 3 Si nanodot buried in the Fe 80 Si 17 Nb 3 . • A saturation magnetization of 244 emu g −1 is proposed for high-efficiency wireless power transfer. • The return loss of the antenna will be tuned to match the designed frequency. • Such a wireless power transfer can be enhanced efficiency up to 97.3%

  2. Study and characterization of FeNi and NiCr(80-20) % w alloys, during and after neutron irradiation, using the resistivity method

    International Nuclear Information System (INIS)

    Otero, Mauro Pereira

    1978-01-01

    We have used the resistivity method with and without neutron irradiation to study the parameters that appear in the Order-Disorder Transitions of Fe Ni(50-50)% at. and Ni Cr( 80 - 20) % w. alloys. The results obtained with Fe Ni are in agreement with those obtained by Marchand at the University of Grenoble. Several isothermal annealings were made in the range 400 - 302 deg C in which T c (Order-Disorder Transition Critical Temperature) was determined between 327 and 310 deg C. The activation energy obtained was E a = 0,49 eV and is in agreement with works of Marchand, Dienes and Damask. As for Ni Cr(80-20)% the following has been done: a) Electrical Properties characterizations, having in mind the technological applications; b) Linear and isothermal annealings were performed to determine the Order-Disorder Transition Critical Temperature (I ) supported by hypothesis made, taking into account the Yano's and Taylor's marks. The-result is T c = (536 +- 4) deg C; c) determination of activation energy E a = (1,36 +- 0.14) eV. The resistivity measurements mere performed by means of the classical 4-wire method. An anisotropy of electrical resistivity was found to exist depending on the sense of the applied electrical field. (author)

  3. W-jet tagging: Optimizing the identification of boosted hadronically-decaying W bosons

    International Nuclear Information System (INIS)

    Cui Yanou; Han Zhenyu; Schwartz, Matthew D.

    2011-01-01

    A method is proposed for distinguishing highly boosted hadronically-decaying W's (W jets) from QCD-jets using jet substructure. Previous methods, such as the filtering/mass-drop method, can give a factor of ∼2 improvement in S/√(B) for jet p T > or approx. 200 GeV. In contrast, a multivariate approach including new discriminants such as R cores, which characterize the shape of the W jet, subjet planar flow, and grooming-sensitivities is shown to provide a much larger factor of ∼5 improvement in S/√(B). For longitudinally polarized W's, such as those coming from many new physics models, the discrimination is even better. Comparing different Monte Carlo simulations, we observe a sensitivity of some variables to the underlying event; however, even with a conservative estimates, the multivariate approach is very powerful. Applications to semileptonic WW resonance searches and all-hadronic W+jet searches at the LHC are also discussed. Code implementing our W-jet tagging algorithm is publicly available at http://jets.physics.harvard.edu/wtag.

  4. Power Management and SRAM for Energy-Autonomous and Low-Power Systems

    Science.gov (United States)

    Chen, Gregory K.

    We demonstrate the two first-known, complete, self-powered millimeter-scale computer systems. These microsystems achieve zero-net-energy operation using solar energy harvesting and ultra-low-power circuits. A medical implant for monitoring intraocular pressure (IOP) is presented as part of a treatment for glaucoma. The 1.5mm3 IOP monitor is easily implantable because of its small size and measures IOP with 0.5mmHg accuracy. It wirelessly transmits data to an external wand while consuming 4.70nJ/bit. This provides rapid feedback about treatment efficacies to decrease physician response time and potentially prevent unnecessary vision loss. A nearly-perpetual temperature sensor is presented that processes data using a 2.1muW near-threshold ARMRTM Cortex-M3(TM) muP that provides a widely-used and trusted programming platform. Energy harvesting and power management techniques for these two microsystems enable energy-autonomous operation. The IOP monitor harvests 80nW of solar power while consuming only 5.3nW, extending lifetime indefinitely. This allows the device to provide medical information for extended periods of time, giving doctors time to converge upon the best glaucoma treatment. The temperature sensor uses on-demand power delivery to improve low-load dc-dc voltage conversion efficiency by 4.75x. It also performs linear regulation to deliver power with low noise, improved load regulation, and tight line regulation. Low-power high-throughput SRAM techniques help millimeter-scale microsystems meet stringent power budgets. VDD scaling in memory decreases energy per access, but also decreases stability margins. These margins can be improved using sizing, VTH selection, and assist circuits, as well as new bitcell designs. Adaptive Crosshairs modulation of SRAM power supplies fixes 70% of parametric failures. Half-differential SRAM design improves stability, reducing VMIN by 72mV. The circuit techniques for energy autonomy presented in this dissertation enable

  5. Prototype of an electric 'integral-ecomotor' for the power range up to 1 kW; Funktionsmuster eines Integral-Sparmotors im Leistungsbereich kleiner 1 kW

    Energy Technology Data Exchange (ETDEWEB)

    Lindegger, M.

    2006-11-15

    Numerous electric motors of our daily use, with power ratings of about 1 kW operate at rather low efficiencies. Their share in the overall electric consumption is considerable. The aim of the research project consisted in the development of an efficient electric motor with incorporated electronic control ('integral-ecomotor'), which may serve as a substitute for usual variable speed squirrel cage three-phase motor. It was shown that the cost of these new motors of 1 kW power output, built with normalised casings, remain similar to those of squirrel cage three phase motors with inverters. Since 2004, the cost of raw materials as copper or aluminium increased considerably, whereas the cost of Neodymium-Iron-Boron magnets remained rather stable. These facts advocate for energy saving motors making use of permanent magnets, requiring much less copper or aluminium than squirrel cage three phase motors. With integral ecomotors, higher efficiencies are achieved at lower masses as compared to usual squirrel cage three-phase motors. In 2004, a first prototype of this ecomotor using permanent magnets, was built. The advantages of improved performances at lower weight were confirmed. During 2005 and 2006, the technology was then improved and matured in a joint research project with 3 industrial partners. (author)

  6. WA80 BGO calorimetry electronics

    International Nuclear Information System (INIS)

    Wintenberg, A.L.; Britton, C.L. Jr.; Ericson, M.N.; Maples, R.A.; Young, G.R.; Awes, T.C.

    1991-01-01

    This paper describes instrumentation designed for BGO scintillator-based calorimetry of particles covering a very wide range of energies (from less than 50 MeV to 50 GeV). The instrumentation was designed to have a measurement accuracy of 0.1% over as much of the energy range as possible so the energy resolution of BGO would be the limiting factor. Two 1.5-cm 2 photodiodes were used per 2.5 cm x 2.5 cm x 25 cm BGO crystal. Both a charge-sensitive preamplifier and a pulse processor were developed specifically for the needs of the WA80 experiment. The preamplifier was designed for high detector capacitance (100 to 700 pF), low integral and differential non-linearity and low power consumption (200 mW). The pulse processor is a time-invariant shaping amplifier with integral peak-detect-and-hold and automatic gain selection circuits. The amplifier use quasi-triangular shaping with 4 μs peaking time, and the hold circuit is gated with a fast first level trigger. The system has more than 20 bits of effective resolution when used with an external 12-bit ADC. Results from beam tests at CERN are presented. 6 refs., 5 figs., 1 tab

  7. High-power stirling-type pulse tube cooler for power engineering applications of high temperature superconductivity; Hochleistungspulsrohrkuehler vom Stirling-Typ fuer energietechnische Anwendungen der Hochtemperatursupraleitung

    Energy Technology Data Exchange (ETDEWEB)

    Dietrich, Marc

    2015-12-15

    For the cooling of high temperature superconducting 4 MVA machines (motors or generators), a single-stage Stirling-type pulse-tube cryocooler was built. The cooling power, which the cryocooler was aimed for, is 80 - 100 W at 30 K with an electrical input power of 10 kW (8 kW pV-power). The advantages of this cooler type compared to traditional cooling concepts are an increased reliability and long maintenance intervals. While single-stage Stirling-type pulse-tube cryocoolers for the temperature range of liquid nitrogen (77 K) are already commercially available, there exist currently no commercial systems for the temperature range near 30 K, which is the important range for applications of high-temperature superconductivity. The experimental setup consisted of a 10 kW linear compressor, type 2S297W, from CFIC Inc. which was used as the pressure wave generator. The compressor was operated by a Micromaster 440 frequency inverter from Siemens, which was controlled by a custom-made computer program. The cold head was made in inline configuration, in order to avoid deflection losses. During the first cool-downs tests a temperature inhomogeneity occurred in the regenerator at low temperature and high pV-power, which was attributed to a constant mass flow (circular dc-flow) within the regenerator. This firstly observed dc-flow, generates a net energy flow from the hot end to the cold end of the regenerator, which reduces the cooling capacity considerably and hence the minimum attainable temperature is severely increased. For the design and optimization of the cold-head, a cryocooler model was initially created using the commercial simulation software Sage, which did not include the regenerator inhomogeneity seen in the experiment. For the modeling of the observed streaming inhomogeneity caused by the dc-flow, the regenerator was replaced by two identical parallel regenerators with variable transverse thermal coupling. In the inhomogeneous case (without dc-flow) the

  8. Power systems for the Doublet III 2-MW ECH system

    International Nuclear Information System (INIS)

    Remsen, D.B. Jr.

    1981-10-01

    A system providing 5 second pulses at 60 GHz from ten 200 kW gyrotrons is being prepared for electron cyclotron heating experiments on Doublet III. The power supply for the gyrotron system is a power supply currently under construction by Universal Voltronics Corporation for the Doublet III neutral beam power supply, and is to have the option of reverse polarity (negative) to fill the needs of the system of ten gyrotons operating in parallel. The output of this power supply is 80 kV at 100A for 5 second pulses with good regulation. The output pulse rise and fall times and fault protection response time are all compatible with the gyrotron requirements

  9. THE USES OF RELIGIOUSS SYMBOLS TO REPRESENT ISLAM (A Study on Religious Soap Opera "Bukan Islam KTP"

    Directory of Open Access Journals (Sweden)

    sholihati siti

    2016-05-01

    Full Text Available This study is entitled THE USES OF RELIGIOUS SYMBOL TO REPRESENT ISLAM (A Study on Religious Soap Opera Bukan Islam KTP. The background of the research is based on the facts of the arbitrary use of symbols to represent Islam shown on Indonesian televisions. The pattern of the use of religious symbols, either verbal or non-verbal symbols are generally explicit, but when examined using appropriate methods, they are actually contained some implicit meanings. The purpose of this study was to discover about how Islam is represented on television religious soap opera using religious symbols and to find out the dominant ideology behind the representation techniques. To analyze the soap operas consist of twenty episodes, the researcher used a semiotic approach by John Fiske on television codes. The results of this study are: (1 the use of verbal symbols to represent Islam potentially creates multiple interpretations when they are spoken by different characters. (2 Some religious terminologies are often used by antagonist player to express anger and disappointment. (3 The soap opera is dominated by verbal violence used by both protagonist and antagonist players, while antagonist player use violence both in verbal and non-verbal forms. The findings about ideology embedded in the soap opera are: (1 capitalist-materialistic ideology, (2 ideology of patriarchy, and (3 violence domination.

  10. Efficient 10 kW diode-pumped Nd:YAG rod laser

    Science.gov (United States)

    Akiyama, Yasuhiro; Takada, Hiroyuki; Sasaki, Mitsuo; Yuasa, Hiroshi; Nishida, Naoto

    2003-03-01

    As a tool for high speed and high precision material processing such as cutting and welding, we developed a rod-type all-solid-state laser with an average power of more than 10 kW, an electrical-optical efficiency of more than 20%, and a laser head volume of less than 0.05 m3. We developed a highly efficient diode pumped module, and successfully obtained electrical-optical efficiencies of 22% in CW operation and 26% in QCW operation at multi-kW output powers. We also succeeded to reduce the laser head volume, and obtained the output power of 12 kW with an efficiency of 23%, and laser head volume of 0.045 m3. We transferred the technology to SHIBAURA mechatronics corp., who started to provide the LD pumped Nd:YAG laser system with output power up to 4.5 kW. We are now continuing development for further high power laser equipment.

  11. Wavefront improvement in an end-pumped high-power Nd:YAG zigzag slab laser.

    Science.gov (United States)

    Shin, Jae Sung; Cha, Yong-Ho; Lim, Gwon; Kim, Yonghee; Kwon, Seong-Ouk; Cha, Byung Heon; Lee, Hyeon Cheor; Kim, Sangin; Koh, Kwang Uoong; Kim, Hyun Tae

    2017-08-07

    Techniques for wavefront improvement in an end-pumped Nd:YAG zigzag slab laser amplifier were proposed and demonstrated experimentally. First, a study on the contact materials was conducted to improve the heat transfer between the slab and cooling blocks and to increase the cooling uniformity. Among many attempts, only the use of silicon oil showed an improvement in the wavefront. Thus, the appropriate silicone oil was applied to the amplifier as a contact material. In addition, the wavefront compensation method using a glass rod array was also applied to the amplifier. A very low wavefront distortion was obtained through the use of a silicone-oil contact and glass rod array. The variance of the optical path difference for the entire beam height was 3.87 μm at a pump power of 10.6 kW, and that for the 80% section was 1.69 μm. The output power from the oscillator was 3.88 kW, which means the maximum output extracted from the amplifier at a pump power of 10.6 kW.

  12. Przemiany stylu edukacyjnego klasy ludowej w Polsce

    Directory of Open Access Journals (Sweden)

    Przemysław Sadura

    2015-12-01

    Full Text Available Wprowadzenie gimnazjum – jednego z elementów zmiany systemu edukacyjnego, dostosowującej go do ogólnych parametrów postfordowskiego kapitalizmu – wpłynęło na styl edukacyjny klasy ludowej w Polsce. Zmiany zachodzące w systemie od reformy w 1999 r., dotyczące ekonomizacji edukacji, parametryzacji i kwantyfikacji wyników edukacyjnych oraz wprowadzenia elementów gry rynkowej do zarządzania i finansowania szkół publicznych, przypominają procesy zachodzące od lat 80. XX w. w krajach zachodnich. Ich wpływ na styl życia klasy ludowej w Polsce wywołuje konsekwencje wynikające z lokalnej specyfiki. Artykuł opiera się na analizie 120 wywiadów pogłębionych przeprowadzonych w latach 2013–2014 z robotnikami, rolnikami i pracownikami fizycznymi w czterech regonach Polski oraz 60 wywiadów z przedstawicielami klasy średniej i wyższej z województwa warmińsko-mazurskiego. Wykazano, że charakterystyka poddanego prawom rynkowym systemu edukacyjnego jest najlepiej dostosowana do kultury klasy średniej, w związku z czym dzieci z rodzin o niższej pozycji społecznej mogą mieć trudności z funkcjonowaniem w takim systemie. Ustalenie to staje się podstawą do formułowania nowych propozycji teoretycznych i badawczych w obszarze badań edukacyjnych.

  13. Preliminary investigation on selective laser melting of 17-4ph steel using high laser powers of up to 1500w

    CSIR Research Space (South Africa)

    Makoana, Nkutwane W

    2017-09-01

    Full Text Available High laser powers of up to 1500W were used to additively manufacture 17-4PH samples. Porosity was measured using the image analysis technique, and all samples are fairly dense with a maximum of 0.42 percent porosity....

  14. Development of high power klystron. 3. Development of klystron No.2

    International Nuclear Information System (INIS)

    Hirano, K.; Wang, Y.L.; Sato, I.

    2000-08-01

    A high power klystron has been developed as the RF source of the high power CW electron linac (10 MeV, 100 mA, 1.249135 GHz). CW power of 1.2 MW and efficiencies over 65% at a beam voltage 85 kV were the design goal. We developed a long pill-box type beryllia window (long pill-box window) withstood the RF power of 1.7 MW (CW) and replaced the standard pill-box window of the prototype klystron with long pill-box window. The high power RF test was carried out with the converted klystron. This klystron has achieved CW RF power of 885 kW and efficiency of 47% at beam voltage of 85 kV. This paper describes key points of the designs to achieve the RF power over 1.2 MW and results of the high power RF test of the second klystron, which has been optimized by simulation codes to improve better efficiency. The second klystron has achieved the maximum efficiency of 56.5% with CW output power of 782 kW at a beam voltage of 80 kV and a cathode current of 20.4 A in present. The third klystron will be manufactured to reflect results of this test. (author)

  15. 75 FR 10026 - Proposed Collection; Comment Request for Forms W-2, W-2c, W-2AS, W-2GU, W-2VI, W-3, W-3c, W-3cPR...

    Science.gov (United States)

    2010-03-04

    ... W-2, W-2c, W-2AS, W-2GU, W-2VI, W-3, W-3c, W-3cPR, W-3PR, and W-3SS AGENCY: Internal Revenue Service....C. 3506(c)(2)(A)). Currently, the IRS is soliciting comments concerning Forms W-2, W-2c, W-2AS, W-2GU, W-2VI, W-3, W-3c, W- 3cPR, W-3PR, and W-3SS. DATES: Written comments should be received on or...

  16. Construction and start-up of a 250 kW natural gas fueled MCFC demonstration power plant

    Energy Technology Data Exchange (ETDEWEB)

    Figueroa, R.A.; Carter, J.; Rivera, R.; Otahal, J. [San Diego Gas & Electric, CA (United States)] [and others

    1996-12-31

    San Diego Gas & Electric (SDG&E) is participating with M-C Power in the development and commercialization program of their internally manifolded heat exchanger (IMHEX{reg_sign}) carbonate fuel cell technology. Development of the IMHEX technology base on the UNOCAL test facility resulted in the demonstration of a 250 kW thermally integrated power plant located at the Naval Air Station at Miramar, California. The members of the commercialization team lead by M-C Power (MCP) include Bechtel Corporation, Stewart & Stevenson Services, Inc., and Ishikawajima-Harima Heavy Industries (IHI). MCP produced the fuel cell stack, Bechtel was responsible for the process engineering including the control system, Stewart & Stevenson was responsible for packaging the process equipment in a skid (pumps, desulfurizer, gas heater, turbo, heat exchanger and stem generator), IHI produced a compact flat plate catalytic reformer operating on natural gas, and SDG&E assumed responsibility for plant construction, start-up and operation of the plant.

  17. Electroanalytical performance of a terbium(III)-selective sensor based on a neutral ionophore in environmental and medicinal samples

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, V.K.; Singh, A.K.; Gupta, Barkha [Indian Institute of Technology-Roorkee, Department of Chemistry, Roorkee (India)

    2008-04-15

    A new highly selective terbium(III) electrode was prepared with a polymeric film doped using S-2-benzothiazolyl-2-amino-{alpha}-(methoxyimino)-4-thiazolethiol acetate as an electroactive material, benzyl acetate (BA) as a plasticizer, and potassium tetrakis(4-chlorophenyl) borate (KTpClPB) as an anionic site in the percentage ratio 3.17:1.58:63.4:31.7 (ionophore-KTpClPB-BA-PVC, w/w). The electrode exhibited a linear response with a near Nernstian slope of 19.5 mV/decade within the concentration range 1.5 x 10{sup -7}-1.0 x 10{sup -2} M terbium ions, with a working pH range from 2.0 to 8.0, and a fast response time of 10 s and presented satisfactory reproducibility. The limit of detection was 9.3 x 10{sup -8} M. The results show that this electrode can be used in ethanol media up to 30% (v/v) concentration without interference. It can be used for 3 months without any considerable divergence in the potentials. Selectivity coefficients for terbium(III) with respect to many cations were investigated. The electrode is highly selective for terbium(III) ions over a large number of monovalent, bivalent, and trivalent cations. This shows the valuable property of the proposed electrode. The stability constant of the ionophore towards Tb{sup 3+} ions was determined with the sandwich membrane method. It was successfully used as an indicator electrode in potentiometric determination of terbium(III) ions with EDTA and in direct determination in tap water and binary mixtures with quantitative results. The utility of the proposed electrode was also determined in the presence of ionic and nonionic surfactants and in the presence of fluoride ions in four pharmaceutical (mouthwash) preparations. (orig.)

  18. Electroanalytical performance of a terbium(III)-selective sensor based on a neutral ionophore in environmental and medicinal samples

    International Nuclear Information System (INIS)

    Gupta, V.K.; Singh, A.K.; Gupta, Barkha

    2008-01-01

    A new highly selective terbium(III) electrode was prepared with a polymeric film doped using S-2-benzothiazolyl-2-amino-α-(methoxyimino)-4-thiazolethiol acetate as an electroactive material, benzyl acetate (BA) as a plasticizer, and potassium tetrakis(4-chlorophenyl) borate (KTpClPB) as an anionic site in the percentage ratio 3.17:1.58:63.4:31.7 (ionophore-KTpClPB-BA-PVC, w/w). The electrode exhibited a linear response with a near Nernstian slope of 19.5 mV/decade within the concentration range 1.5 x 10 -7 -1.0 x 10 -2 M terbium ions, with a working pH range from 2.0 to 8.0, and a fast response time of 10 s and presented satisfactory reproducibility. The limit of detection was 9.3 x 10 -8 M. The results show that this electrode can be used in ethanol media up to 30% (v/v) concentration without interference. It can be used for 3 months without any considerable divergence in the potentials. Selectivity coefficients for terbium(III) with respect to many cations were investigated. The electrode is highly selective for terbium(III) ions over a large number of monovalent, bivalent, and trivalent cations. This shows the valuable property of the proposed electrode. The stability constant of the ionophore towards Tb 3+ ions was determined with the sandwich membrane method. It was successfully used as an indicator electrode in potentiometric determination of terbium(III) ions with EDTA and in direct determination in tap water and binary mixtures with quantitative results. The utility of the proposed electrode was also determined in the presence of ionic and nonionic surfactants and in the presence of fluoride ions in four pharmaceutical (mouthwash) preparations. (orig.)

  19. Influence of Selective Laser Melting Processing Parameters of Co-Cr-W Powders on the Roughness of Exterior Surfaces

    Science.gov (United States)

    Baciu, M. A.; Baciu, E. R.; Bejinariu, C.; Toma, S. L.; Danila, A.; Baciu, C.

    2018-06-01

    Selective Laser Melting (SLM) represents an Additive Manufacturing method widely used in medical practice, mainly in dental medicine. The powder of 59% Co, 25% Cr, 2.5% W alloy (Starbond CoS Powder 55, S&S Scheftner C, Germany) was processed (SLM) on a Realizer SLM 50 device (SLM Solution, Germany). After laser processing and simple sanding with Al2O3 or two-phase sanding (Al2O3 and glass balls), measurements of surface roughness were conducted. This paper presents the influences exercised by laser power (P = 60 W, 80 W and 100 W), the scanning speed (vscan = 333 mm/s, 500 mm/s and 1000 mm/s) and exposure time (te = 20 µs, 40 µs and 60 µs) on the roughness of surfaces obtained by SLM processing. Based on the experimental results obtained for roughness (Ra), some recommendations regarding the choice of favorable combinations among the values of technological parameters under study in order to obtain the surface quality necessary for subsequent applications of the processed parts (SLM) have been made.

  20. Generation of 14  W at 589  nm by frequency doubling of high-power CW linearly polarized Raman fiber laser radiation in MgO:sPPLT crystal.

    Science.gov (United States)

    Surin, A A; Borisenko, T E; Larin, S V

    2016-06-01

    We introduce an efficient, single-mode, linearly polarized continuous wave (CW) Raman fiber laser (RFL), operating at 1178 nm, with 65 W maximum output power and a narrow linewidth of 0.1 nm. Single-pass second-harmonic generation was demonstrated using a 20 mm long MgO-doped stoichiometric periodically polled lithium tantalate (MgO:sPPLT) crystal pumped by RFL radiation. Output power of 14 W at 589 nm with 22% conversion efficiency was achieved. The possibility of further power scaling is considered, as no crystal degradation was observed at these power levels.

  1. Closeout of IE Bulletin 80-15: Possible loss of Emergency Notification System (ENS) with loss of offsite power

    International Nuclear Information System (INIS)

    Foley, W.J.; Dean, R.S.; Hennick, A.

    1990-12-01

    Documentation is provided in this report for the closeout of IE Bulletin 80-15 for nuclear power reactors. This bulletin pertained to a possible loss of the Emergency Notification System (ENS) upon loss of offsite power. Closeout is based on the implementation and verification of six (6) required actions by licensees of nuclear power reactors in operation or near to receiving an operating license when the bulletin was issued on June 18, 1980. Evaluation of utility responses and NRC/Region inspection reports indicates that the bulletin is closed for all of the 69 nuclear power reactors to which it was issued for action and which were not shut down indefinitely or permanently at the time of issuance of this report. Background information is supplied in the Introduction and Appendix A. Nuclear fuel facilities as well as nuclear power facilities were identified in the enclosures to the bulletin. However, per an NRC memorandum, the closeout of the bulletin for nuclear fuel facilities is not within the scope of this report

  2. The influence of RF power on the electrical properties of sputtered amorphous In—Ga—Zn—O thin films and devices

    International Nuclear Information System (INIS)

    Shi Junfei; Dong Chengyuan; Wu Jie; Chen Yuting; Zhan Runze; Dai Wenjun

    2013-01-01

    The influence of radio frequency (RF) power on the properties of magnetron sputtered amorphous indium gallium zinc oxide (a-IGZO) thin films and the related thin-film transistor (TFT) devices is investigated comprehensively. A series of a-IGZO thin films prepared with magnetron sputtering at various RF powers are examined. The results prove that the deposition rate sensitively depends on RF power. In addition, the carrier concentration increases from 0.91 × 10 19 to 2.15 × 10 19 cm −3 with the RF power rising from 40 to 80 W, which may account for the corresponding decrease in the resistivity of the a-IGZO thin films. No evident impacts of RF power are observed on the surface roughness, crystalline nature and stoichiometry of the a-IGZO samples. On the other hand, optical transmittance is apparently influenced by RF power where the extracted optical band-gap value increases from 3.48 to 3.56 eV with RF power varying from 40 to 80 W, as is supposed to result from the carrier-induced band-filling effect. The rise in RF power can also affect the performance of a-IGZO TFTs, in particular by increasing the field-effect mobility clearly, which is assumed to be due to the alteration of the extended states in a-IGZO thin films. (semiconductor devices)

  3. A 25 W 70% Efficiency Doherty Power Amplifier at 6 dB Output Back-Off for 2.4 GHz Applications with VGS, PEAK

    Directory of Open Access Journals (Sweden)

    Jorge Moreno Rubio

    2015-01-01

    Full Text Available This paper shows the design and simulation results of a hybrid Doherty power amplifier. The amplifier has been designed at 2,4 GHz, obtaining power-added efficiency above 70 % for 6 dB output power back-off, together with a small signal gain of 17 dB. Design and analysis equations are presented considering class AB bias conditions for the main amplifier and class C for the peak one in back-off larger than 6 dB, and FET device assumption. An additional control on the bias point of the peak device has been carried out, in order to increase the gain on the Doherty region and ease the design of the peak branch. A Cree’s GaN-HEMT CGH40010F device has been used with a nonlinear model guarantied up to 6 GHz and with an expected output power of 10 W. The obtained output power is higher than 25-W. The simulation has been carried out using Agilent ADS CAD tools. The present design could present the state of the art in terms of continuous-wave (CW characterization

  4. Experimental 1 kW 20 cell PEFC stack

    Energy Technology Data Exchange (ETDEWEB)

    Buechi, F N; Marmy, C A; Scherer, G G [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Ruge, M [Swiss Federal Inst. of Technology (ETH), Zuerich (Switzerland)

    1999-08-01

    A 20-cell PEFC stack was designed and built. Resin impregnated graphite was used as bipolar plate material. The air cooling of the stack was optimized by introducing high surface structures into the open space of the cooling plates. At {eta} (H{sub 2} LHV) = 0.5 a power of 880 W was obtained under conditions of low gas-pressures of 1.15 bar{sub a}. The auxiliary power for process air supply and cooling at 880 W power is less than 7% of the power output, indicating that the described system may be operated at a high efficiency. (author) 5 figs., 2 refs.

  5. A high-flux entanglement source based on a doubly resonant optical parametric amplifier

    International Nuclear Information System (INIS)

    Kuklewicz, Christopher E; Keskiner, Eser; Wong, Franco N C; Shapiro, Jeffrey H

    2002-01-01

    A 532 nm pumped type-II phase-matched, doubly resonant KTP optical parametric amplifier (OPA) was operated near frequency degeneracy to yield an inferred downconverted photon pair production rate of 1.7x10 6 s -1 at a pump power of 100 μW. The OPA output consisted of three components: narrowband doubly resonant mode pairs; narrowband singly resonant mode pairs for which either the signal or idler was resonant with the cavity and broadband nonresonant mode pairs. Under frequency-degenerate operation, the broadband nonresonant mode pairs were polarization triplet states. We observed quantum interference between the orthogonally polarized photons of the triplet states when they were analysed with a polarizer set at 45 deg. relative to the OPA's output polarizations, leading to reduced coincidence counts

  6. Tuning range and output power optimization of an external-cavity GaN diode laser at 455 nm

    DEFF Research Database (Denmark)

    Chi, Mingjun; Jensen, Ole Bjarlin; Petersen, Paul Michael

    2016-01-01

    In this paper we discuss how different feedback gratings affect the tuning range and the output power of external feedback diode laser systems. A tunable high-power narrow-spectrum external-cavity diode laser system around 455 nm is investigated. The laser system is based on a high-power GaN diode...... laser in a Littrow external-cavity. Both a holographic diffraction grating and a ruled diffraction grating are used as feedback elements in the external cavity. The output power, spectral bandwidth, and tunable range of the external cavity diode laser system are measured and compared with the two...... gratings at different injected currents. When the holographic grating is used, the laser system can be tuned over a range of 1.4 nm with an output power around 530 mW. When the ruled grating is used, the laser system can be tuned over a range of 6.0 nm with an output power around 80 mW. The results can...

  7. Effect of Sodium Dodecyl Sulfate (SDS) and Tween 80 on Cell Viability in an Air-Cathode Microbial Fuel Cell

    KAUST Repository

    Fregoso, Luisa

    2011-07-01

    Microbial fuel cells (MFCs) generate current via electrochemical reactions produced by bacteria attached to the anode that oxidize organic matter. Due to their high volume use in household products, some concentration of surfactant will reach wastewater treatment plants. The average surfactant concentration in wastewater ranges from 10 to 20 mg L-1, and up to 300 mg L-1, for domestic and industrial wastewaters, respectively. This study aimed to demonstrate the feasibility of enhancing power production by adding Tween 80 and SDS surfactants to air-cathode MFCs, and their effect in cell viability at the anodic biofilm. In order to analyze the effect of anionic and nonionic surfactants in MFCs performance, eight MFCs were spiked with two types of surfactants, the anionic surfactant sodium dodecyl sulfate (SDS) and the nonionic surfactant Tween® 80 at two different concentrations 10 and 100 mg L-1. Cell viability at the anodic biofilms was examined using the LIVE/DEAD BacLight viability assay and images were visualized with a confocal laser scanning microscope. The electrochemical results demonstrate that, for an air-cathode MFC operating on 1 g L-1 acetate in a fed-batch mode, reactors where SDS was added show a lower overall performance, maximum PD of 544 mW m-2, CE of 12.3%, Rint of 322 Ω (10 mg L-1) and maximum PD of 265 mW m-2, CE of 9.4%, Rint of 758 Ω (100 mg L-1). Reactors where Tween 80 was added show quite stable performance, maximum PD of 623 mW m-2, CE of 15.4%, Rint of 216 Ω (10 mg L-1) and maximum PD of 591 mW m-2, CE of 10.8%, Rint of 279 Ω (100 mg L-1), compared with reactors operating at only acetate as a substrate, maximum PD of 574 mW m-2. Confocal microscopy images confirm this observation and biofilm viability appeared severely compromised in SDS reactors, especially at high concentrations. This study has opened up a whole new research area in determining which types of surfactants are toxic to the anodic biofilm and to further investigate the

  8. Thermoelectric self-cooling for power electronics: Increasing the cooling power

    International Nuclear Information System (INIS)

    Martinez, Alvaro; Astrain, David; Aranguren, Patricia

    2016-01-01

    Thermoelectric self-cooling was firstly conceived to increase, without electricity consumption, the cooling power of passive cooling systems. This paper studies the combination of heat pipe exchangers and thermoelectric self-cooling, and demonstrates its applicability to the cooling of power electronics. Experimental tests indicate that source-to-ambient thermal resistance reduces by around 30% when thermoelectric self-cooling system is installed, compared to that of the heat pipe exchanger under natural convection. Neither additional electric power nor cooling fluids are required. This thermal resistance reaches 0.346 K/W for a heat flux of 24.1 kW/m"2, being one order of magnitude lower than that obtained in previous designs. In addition, the system adapts to the cooling demand, reducing this thermal resistance for increasing heat. Simulation tests have indicated that simple system modifications allow relevant improvements in the cooling power. Replacement of a thermoelectric module with a thermal bridge leads to 33.54 kW/m"2 of top cooling power. Likewise, thermoelectric modules with shorter legs and higher number of pairs lead to a top cooling power of 44.17 kW/m"2. These results demonstrate the applicability of thermoelectric self-cooling to power electronics. - Highlights: • Cooling power of passive systems increased. • No electric power consumption. • Applicable for the cooling of power electronics. • Up to 44.17 kW/m"2 of cooling power, one order of magnitude higher. • Source-to-ambient thermal resistance reduces by 30%.

  9. Cusp Guns for Helical-Waveguide Gyro-TWTs of a High-Gain High-Power W-Band Amplifier Cascade

    Science.gov (United States)

    Manuilov, V. N.; Samsonov, S. V.; Mishakin, S. V.; Klimov, A. V.; Leshcheva, K. A.

    2018-02-01

    The evaluation, design, and simulations of two different electron guns generating the beams for W-band second cyclotron harmonic gyro-TWTs forming a high-gain powerful amplifier cascade are presented. The optimum configurations of the systems creating nearly axis-encircling electron beams having velocity pitch-factor up to 1.5, voltage/current of 40 kV/0.5 A, and 100 kV/13 A with acceptable velocity spreads have been found and are presented.

  10. A 600-µW ultra-low-power associative processor for image pattern recognition employing magnetic tunnel junction-based nonvolatile memories with autonomic intelligent power-gating scheme

    Science.gov (United States)

    Ma, Yitao; Miura, Sadahiko; Honjo, Hiroaki; Ikeda, Shoji; Hanyu, Takahiro; Ohno, Hideo; Endoh, Tetsuo

    2016-04-01

    A novel associative processor using magnetic tunnel junction (MTJ)-based nonvolatile memories has been proposed and fabricated under a 90 nm CMOS/70 nm perpendicular-MTJ (p-MTJ) hybrid process for achieving the exceptionally low-power performance of image pattern recognition. A four-transistor 2-MTJ (4T-2MTJ) spin transfer torque magnetoresistive random access memory was adopted to completely eliminate the standby power. A self-directed intelligent power-gating (IPG) scheme specialized for this associative processor is employed to optimize the operation power by only autonomously activating currently accessed memory cells. The operations of a prototype chip at 20 MHz are demonstrated by measurement. The proposed processor can successfully carry out single texture pattern matching within 6.5 µs using 128-dimension bag-of-feature patterns, and the measured average operation power of the entire processor core is only 600 µW. Compared with the twin chip designed with 6T static random access memory, 91.2% power reductions are achieved. More than 88.0% power reductions are obtained compared with the latest associative memories. The further power performance analysis is discussed in detail, which verifies the special superiority of the proposed processor in power consumption for large-capacity memory-based VLSI systems.

  11. Thermophotovoltaic Arrays for Electrical Power Generation

    International Nuclear Information System (INIS)

    Sarnoff Corporation

    2003-01-01

    Sarnoff has designed an integrated array of thermophotovoltaic (TPV) cells based on the In(Al)GaAsSb/GaSb materials system. These arrays will be used in a system to generate electrical power from a radioisotope heat source that radiates at temperatures from 700 to 1000 C. Two arrays sandwich the slab heat source and will be connected in series to build voltage. Between the arrays and the heat source is a spectral control filter that transmits above-bandgap radiation and reflects below-bandgap radiation. The goal is to generate 5 mW of electrical power at 3 V from a 700 C radiant source. Sarnoff is a leader in antimonide-based TPV cell development. InGaAsSb cells with a bandgap of 0.53 eV have operated at system conversion efficiencies greater than 17%. The system included a front-surface filter, and a 905 C radiation source. The cells were grown via organo-metallic vapor-phase epitaxy. Sarnoff will bring this experience to bear on the proposed project. The authors first describe array and cell architecture. They then present calculated results showing that about 80 mW of power can be obtained from a 700 C radiator. Using a conservative array design, a 5-V output is possible

  12. Design and development of a high-power, 500 kV pulsed line

    International Nuclear Information System (INIS)

    Nicolas, A.

    A study was made of very high voltage (500 kV) pulse production for 50 ns at half height. A coaxial line was coupled to a Marx generator for obtaining the pulses on an impedance-adapted electron diode. The maximum power obtained was 6.4 x 10 10 W with a current front in the diode of about 30 ns (80 ns pulse length at half height)

  13. Development of 3D models of buildings for containment of the nuclear power plant of Almaraz and of the Trillo Nuclear with the GOTHIC 8.0 code

    International Nuclear Information System (INIS)

    Jimenez, G.; Bocanegra Melian, R.; Fernandez Cosils, K.; Barreira Pereira, P.; Rey Peinado, L.; Posada Barral, J. M.

    2014-01-01

    The objective of the first phase of the research of CNAT and the UPM project is the construction of several three-dimensional models detailed GOTHIC 8.0 code of containment of a buildings plant type PWR-W and KWU, corresponding to the Central Nuclear de Almaraz (CNA) and Trillo (CNT) respectively. (Author)

  14. Development of 10kW SOFC module

    Energy Technology Data Exchange (ETDEWEB)

    Hisatome, N.; Nagata, K. [Mitsubishi Heavy Industries, Ltd., Nagasaki (Japan); Kakigami, S. [Electric Power Development Co., Inc., Tokyo (Japan)] [and others

    1996-12-31

    Mitsubishi Heavy industries, Ltd. (MHI) has been developing tubular type Solid Oxide Fuel Cells (SOFC) since 1984. A 1 kW module of SOFC has been continuously operated for 3,000 hours with 2 scheduled thermal cycles at Electric Power Development Co., Inc. (EPDC) Wakamatsu Power Station in 1993. We have obtained of 34% (HHV as H{sub 2}) module efficiency and deterioration rate of 2% Per 1,000 hours in this field test. As for next step, we have developed 10 kW module in 1995. The 10 kW module has been operated for 5,000 hours continuously. This module does not need heating support to maintain the operation temperature, and the module efficiency was 34% (HHV as H{sub 2}). On the other hand, we have started developing the technology of pressurized SOFC. In 1996, pressurized MW module has been tested at MHI Nagasaki Shipyard & Machinery, Works. We are now planning the development of pressurized 10 kW module.

  15. Precise determination of W anfd Z masses in UA2

    International Nuclear Information System (INIS)

    Lefebvre, M.

    1990-01-01

    The UA2 experiment has collected large samples of W and Z events during the 1988 and 1989 runs at the CERN antipp Collider at √s = 630 GeV. These samples have been used to perform precise measurements of the masses of the W and Z bosons. After a careful analysis of systematic errors, an improved result is obtained for the mass ratio M W /M Z . This provides a new value for the weak mixing parameter sin 2 θ W . Furthermore, it can be combined with recent measurements of the Z mass from e + e - colliders to give an absolute measurement of the W mass, leading to the result m W = 80.49 ± 0.43(stat) ± 0.24(syst) GeV

  16. W-320 Department of Health documentation

    International Nuclear Information System (INIS)

    Bailey, J.W.

    1998-01-01

    The purpose of this document is to gather information required to show that Project W-320 is in compliance with Washington State Department of Health requirements as specified in Radioactive Air Emissions Notice of Construction Project W-320, Tank 241-C-106 Sluicing, DOE/RL-95-45. Specifically, that W-320 is in compliance with ASME N509-1989 (Nuclear Power Plant Air-Cleaning Units and Components) and ASME N5 10-1989 (Testing of Nuclear Air Treatment Systems) for the 296-C-006 exhaust system

  17. W-320 Department of Health documentation

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, J.W.

    1998-08-07

    The purpose of this document is to gather information required to show that Project W-320 is in compliance with Washington State Department of Health requirements as specified in Radioactive Air Emissions Notice of Construction Project W-320, Tank 241-C-106 Sluicing, DOE/RL-95-45. Specifically, that W-320 is in compliance with ASME N509-1989 (Nuclear Power Plant Air-Cleaning Units and Components) and ASME N5 10-1989 (Testing of Nuclear Air Treatment Systems) for the 296-C-006 exhaust system.

  18. Mechanical power, thrust power and propelling efficiency: relationships with elite sprint swimming performance.

    Science.gov (United States)

    Gatta, Giorgio; Cortesi, Matteo; Swaine, Ian; Zamparo, Paola

    2018-03-01

    The purpose of this study was to explore the relationships between mechanical power, thrust power, propelling efficiency and sprint performance in elite swimmers. Mechanical power was measured in 12 elite sprint male swimmers: (1) in the laboratory, by using a whole-body swimming ergometer (W' TOT ) and (2) in the pool, by measuring full tethered swimming force (F T ) and maximal swimming velocity (V max ): W' T  = F T  · V max . Propelling efficiency (η P ) was estimated based on the "paddle wheel model" at V max . V max was 2.17 ± 0.06 m · s -1 , η P was 0.39 ± 0.02, W' T was 374 ± 62 W and W' TOT was 941 ± 92 W. V max was better related to W' T (useful power output: R = 0.943, P swimming performance. The ratio W' T /W' TOT (0.40 ± 0.04) represents the fraction of total mechanical power that can be utilised in water (e.g., η P ) and was indeed the same as that estimated based on the "paddle wheel model"; this supports the use of this model to estimate η P in swimming.

  19. Measuring the mass of the W{sup {+-}} boson in the ALEPH experiment; Mesure de la masse du boson W{sup {+-}} dans l'experience ALEPH

    Energy Technology Data Exchange (ETDEWEB)

    Boumediene, D.E

    2002-05-01

    The W boson plays an important role in the standard model of weak interactions, its mass is predictable and its measurement is an efficient way to test the theory and to challenge experimental data. This thesis is dedicated to the measurement of the W mass (m{sub W}) through the ALEPH experiment. 3 important points are treated: measuring techniques, systematic effects and impact of the value measured on the standard model. As for measuring techniques: all the decay products of W have been reconstructed, this reconstruction is dependent on the decay way and has an impact on the determination of the mass. For the decay W{sup +}W{sup -} {yields} {tau}{nu}qq-bar, a specific reconstruction has been studied and used for every step of the measurement (selection, kinematic adjustment, adjustment of m{sub W}), this technique has improved the resolution of m{sub W}. For the leptonic decay W{sup +}W{sup -} {yields} l{nu}l{nu}, we have focused on the adjustment technique of m{sub W}, for the decays W{sup +}W{sup -} {yields} l{nu}qq-bar and W{sup +}W{sup -} {yields} qq-bar qq-bar, the standard measurement technique of ALEPH has been used. As for systematic effects, the statistical precision of the measurement campaign is high so it is necessary to understand the systematic effects that have an impact on the measured value. 2 effects have been thoroughly studied: the colour interconnection effect that concerns only the hadronic decay with 4 jets, the second effect appears in the simulation of showers in calorimeter-detectors. 2 values for m{sub W} are proposed, one that was obtained by only measuring the direction and the energy of the jet and the second one by discarding all the problematic events that were reconstructed in the detector. We obtain: m{sub W} = (80,392 {+-} 0,053) GeV/c{sup 2} and m{sub W} = (80,358 {+-} 0,050) GeV/c{sup 2}. By combining these values to the internationally agreed data, it has been possible to adjust the mass of the Higgs' boson and to give

  20. Cladding-pumped 70-kW-peak-power 2-ns-pulse Er-doped fiber amplifier

    Science.gov (United States)

    Khudyakov, M. M.; Bubnov, M. M.; Senatorov, A. K.; Lipatov, D. S.; Guryanov, A. N.; Rybaltovsky, A. A.; Butov, O. V.; Kotov, L. V.; Likhachev, M. E.

    2018-02-01

    An all-fiber pulsed erbium laser with pulse width of 2.4 ns working in a MOPA configuration has been created. Cladding pumped double clad erbium doped large mode area fiber was used in the final stage amplifier. Peculiarity of the current work is utilization of custom-made multimode diode wavelength stabilized at 981+/-0.5 nm - wavelength of maximum absorption by Er ions. It allowed us to shorten Er-doped fiber down to 1.7 m and keep a reasonably high pump-to signal conversion efficiency of 8.4%. The record output peak power for all-fiber amplifiers of 84 kW was achieved within 1555.9+/-0.15 nm spectral range.

  1. 3.1 W narrowband blue external cavity diode laser

    Science.gov (United States)

    Peng, Jue; Ren, Huaijin; Zhou, Kun; Li, Yi; Du, Weichuan; Gao, Songxin; Li, Ruijun; Liu, Jianping; Li, Deyao; Yang, Hui

    2018-03-01

    We reported a high-power narrowband blue diode laser which is suitable for subsequent nonlinear frequency conversion into the deep ultraviolet (DUV) spectral range. The laser is based on an external cavity diode laser (ECDL) system using a commercially available GaN-based high-power blue laser diode emitting at 448 nm. Longitudinal mode selection is realized by using a surface diffraction grating in Littrow configuration. The diffraction efficiency of the grating was optimized by controlling the polarization state of the laser beam incident on the grating. A maximum optical output power of 3.1 W in continuous-wave operation with a spectral width of 60 pm and a side-mode suppression ratio (SMSR) larger than 10 dB at 448.4 nm is achieved. Based on the experimental spectra and output powers, the theoretical efficiency and output power of the subsequent nonlinear frequency conversion were calculated according to the Boyd- Kleinman theory. The single-pass conversion efficiency and output power is expected to be 1.9×10-4 and 0.57 mW, respectively, at the 3.1 W output power of the ECDL. The high-power narrowband blue diode laser is very promising as pump source in the subsequent nonlinear frequency conversion.

  2. Inductive-pulsed power supplying system for a betatron electromagnet

    International Nuclear Information System (INIS)

    Otrubyannikov, Yu.A.; Safronov, A.S.

    1984-01-01

    Circuit of producing quasitriangular current pulses designed for the pulsed power supply system of betatron electromagnet is described. Introduction of additional winding into electromagnet provides circuit galvanic isolation, artificial commutation of basic circuit thyristors and inductive power input to the winding during thyristor commutation. The considered system is used for excitation of betatron electromagnet up to 18 MeV. Magnetic field energy equals 1100 Y. The maximal voltage in energy storage capacitor - 4.8 kV. Current amplitude in basic winding - 335 A. The number of loops in basic winding equals 80, in additional one - 32. Current pulse duration in electromagnet-3.8 ms. The system provides operation with controlled current pulse frequency from 0 up to 150 Hz. The maximal consumption power - 18 kW

  3. 2-kW single-mode fiber laser employing bidirectional-pump scheme

    Science.gov (United States)

    Zhang, Fan; Zheng, Wenyou; Shi, Pengyang; Zhang, Xinhai

    2018-01-01

    2kW single-mode fiber laser with two cascade home-made cladding light strippers (CLSs) by employing bidirectionalpump scheme has been demonstrated. 2.009 kW signal power is obtained when pump power is 2.63 kW and the slope efficiency is 76.6%. Raman Stokes light is less than -47 dB at 2.009 kW even with a 10-m delivery fiber with core/inner cladding diameter of 20/400um. The beam quality M2<=1.2 and the spectral FWHM bandwidth is 4.34nm. There is no transverse mode instability and the output power stability of +/-0.14% is achieved by special thermal management for a more uniform temperature distribution on the Yb-doped gain fiber.

  4. Low-voltage 96 dB snapshot CMOS image sensor with 4.5 nW power dissipation per pixel.

    Science.gov (United States)

    Spivak, Arthur; Teman, Adam; Belenky, Alexander; Yadid-Pecht, Orly; Fish, Alexander

    2012-01-01

    Modern "smart" CMOS sensors have penetrated into various applications, such as surveillance systems, bio-medical applications, digital cameras, cellular phones and many others. Reducing the power of these sensors continuously challenges designers. In this paper, a low power global shutter CMOS image sensor with Wide Dynamic Range (WDR) ability is presented. This sensor features several power reduction techniques, including a dual voltage supply, a selective power down, transistors with different threshold voltages, a non-rationed logic, and a low voltage static memory. A combination of all these approaches has enabled the design of the low voltage "smart" image sensor, which is capable of reaching a remarkable dynamic range, while consuming very low power. The proposed power-saving solutions have allowed the maintenance of the standard architecture of the sensor, reducing both the time and the cost of the design. In order to maintain the image quality, a relation between the sensor performance and power has been analyzed and a mathematical model, describing the sensor Signal to Noise Ratio (SNR) and Dynamic Range (DR) as a function of the power supplies, is proposed. The described sensor was implemented in a 0.18 um CMOS process and successfully tested in the laboratory. An SNR of 48 dB and DR of 96 dB were achieved with a power dissipation of 4.5 nW per pixel.

  5. Minimization of emissions. (CO and NO) on a 300 kW wood fuel boiler

    International Nuclear Information System (INIS)

    Johansson, Erik

    1997-01-01

    The purpose with this investigation was to study a 300 kW power plant in Ed, Dalsland that is using biomass as fuel and to reduce CO and NO-pollutants as much as possible. The experiments were performed according to statistical experimental design and the result was compared with similar studies. The most important results of the present work were: Today, the boiler is using biomass with too much moisture and that's the reason why the smoke contains a great quantity of CO. This could be reduced with a lower quantity of moisture in the biomass or rebuilding of the boiler. Doors and dampers should be fully closed so air can't pass through because that would reduce the energy losses in the smoke. The automatic control should be changed to reduce the time that biomass are not transported in to the boiler. Biomass with low content of moisture (about 15 %) are a good fuel in the boiler. The smoke needs to be measured continuously to reduce the pollutants because it is not possible to detect visually. If a low amount of oxygen in the smoke (7 %) and high amount of primary air (52 % of total air) and the plant is using low power (120 kW), pollutants is reduced. When using middle power (190 kW), a low amount of oxygen in the smoke is also needed (7%) but a smaller amount of air to the bed (40%) will reduce pollutants. The reason for this is probably that too much air in the bed will make it too cool. The result showed that by using statistical experimental design the amount of CO was reduced with 45 % to 263 ppm and the amount of NO reduced with 80 % to 30 ppm (51 mg/MJ NO 2 ) while using biomass with 34 % moisture Examination paper. 28 refs, 13 figs, 9 tabs, appendixes

  6. A 35 GHz wireless millimeter-wave power sensor based on GaAs micromachining technology

    International Nuclear Information System (INIS)

    Wang, De-bo; Liao, Xiao-ping

    2012-01-01

    A novel MEMS wireless millimeter-wave power sensor based on GaAs MMIC technology is presented in this paper. The principle of this wireless millimeter-wave power sensor is explained. It is designed and fabricated using MEMS technology and the GaAs MMIC process. With the millimeter-wave power range from 0.1 to 80 mW, the sensitivity of the wireless millimeter-wave power sensor is about 0.246 mV mW −1 at 35 GHz. In order to verify the power detection capability, this wireless power sensor is mounted on a PCB which influences the microwave performance of the CPW-fed antenna including the return loss and the radiation pattern. The frequency-dependent characteristic and the degree-dependent characteristic of this wireless power sensor are researched. Furthermore, in addition to the combination of the advantages of CPW-fed antenna with the advantages of the thermoelectric power sensor, another significant advantage of this wireless millimeter-wave power sensor is that it can be integrated with MMICs and other planar connecting circuit structures with zero dc power consumption. These features make it suitable for various applications ranging from the environment or space radiation detection systems to radar receiver and transmitter systems. (paper)

  7. A 526 W Diode-Pumped Nd:YAG Ceramic Slab Laser

    International Nuclear Information System (INIS)

    Chen Yan-Zhong; Bo Yong; Xu Jian; Xu Yi-Ting; Xu Jia-Lin; Guo Ya-Ding; Yang Feng-Tu; Peng Qin-Jun; Cui Da-Fu; Xu Zu-Yan; Liu Wen-Bin; Jiang Ben-Xue; Kou Hua-Min; Pan Yu-Bai; Jiang Dong-Liang

    2011-01-01

    A diode-side-pumped Nd:YAG ceramic slab laser with a high power output is presented. An average power of 526 W is achieved at 1064 nm with a repetition rate of 120 Hz and a pulse width of 180 μs from a 93mm × 52mm × 8 mm ceramic slab at a pump power of 1928 W, corresponding to an optical-to-optical efficiency of 27.3%. (fundamental areas of phenomenology(including applications))

  8. General approach to high power, coherent visible and ultraviolet light sources

    DEFF Research Database (Denmark)

    Andersen, Martin Thalbitzer

    by cascaded second harmonic and sum frequency generation using periodically poled KTP and BBO for the SHG and SFG process, respectively. The 355nm light is used to promote different photo induced reactions. The main limitation of reaching any desired wavelength in the visible spectrum using sum frequency...

  9. Power balance in ELMO Bumpy Torus: bulk electrons and ions in a 37 kW discharge

    International Nuclear Information System (INIS)

    McNeill, D.H.

    1985-10-01

    The power balance of the bulk electrons and ions in discharges with 37 kW of applied microwave power in the ELMO Bumpy Torus (EBT) is examined in a zero-dimensional model using data on the intensity and linewidth of the molecular and atomic hydrogen emission. At least 60% of the applied power is ultimately dissipated by processes involving the neutral particles, including dissociation of molecules, ionization of and radiation from atoms, and heating of cold electrons produced during atomic ionization. The molecular influx rate and the density of atoms are used independently to determine the bulk electron particle confinement time, and an upper bound estimate is made of the diffusional power loss from the bulk plasma electrons. Parameters derived from the basic spectroscopic data presented in this paper include the neutral atom density 2 - 5x10 10 cm -3 , incident molecular flux 3 - 5x10 15 cm -2 s -1 , bulk ion temperature approx. =3 eV, and particle confinement time <1.1 ms. The bulk electron energy confinement time is 0.7 ms or less in the standard operating regime. Published data on the nonthermal electron and ion populations in the plasma are used to evaluate approximately the overall energy flow in the discharge. 54 refs

  10. Optimized Envelope Tracking Power Supply for Tetra2 Base Station RF Power Amplifier

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael Andreas E.

    2008-01-01

    An ultra-fast tracking power supply (UFTPS) for envelope tracking in a 50kHz 64-QAM Tetra2 base station power amplification system is demonstrated. A simple method for optimizing the step response of the PID+PD sliding-mode control system is presented and demonstrated, along with a PLL-based scheme...... application. Also demonstrated is the effect of non-zero UFTPS output impedance on envelope tracking performance. At 13W average (156W peak) RF output, a reduction of DC input power consumption from 93W (14% efficiency) to 54W (24% efficiency) is obtained by moving from a fixed RF power amplifier supply...

  11. Mixed-mode distribution systems for high average power electron cyclotron heating

    International Nuclear Information System (INIS)

    White, T.L.; Kimrey, H.D.; Bigelow, T.S.

    1984-01-01

    The ELMO Bumpy Torus-Scale (EBT-S) experiment consists of 24 simple magnetic mirrors joined end-to-end to form a torus of closed magnetic field lines. In this paper, we first describe an 80% efficient mixed-mode unpolarized heating system which couples 28-GHz microwave power to the midplane of the 24 EBT-S cavities. The system consists of two radiused bends feeding a quasi-optical mixed-mode toroidal distribution manifold. Balancing power to the 24 cavities is determined by detailed computer ray tracing. A second 28-GHz electron cyclotron heating (ECH) system using a polarized grid high field launcher is described. The launcher penetrates the fundamental ECH resonant surface without a vacuum window with no observable breakdown up to 1 kW/cm 2 (source limited) with 24 kW delivered to the plasma. This system uses the same mixed-mode output as the first system but polarizes the launched power by using a grid of WR42 apertures. The efficiency of this system is 32%, but can be improved by feeding multiple launchers from a separate distribution manifold

  12. Simultaneous Q-switching and mode-locking in an intracavity frequency doubled diode-pumped Nd:YVO4 / KTP green laser with Cr4+:YAG

    International Nuclear Information System (INIS)

    Mukhopadhyay, P. K.; Ranganathan, K.; George, J.; Nathan, T. P. S.; Alsous, M. B.

    2007-01-01

    We report intracavity second harmonic (at 532 nm) generation in passively Q-switched mode-locked Nd: YVO4 laser. The width of a typical Q-switched envelope of the mode locked pulses for the green laser was around 65 ± 5 ns and the repetition rate for the mode locked pulses was 400 MHz. The intracavity frequency doubling significantly improves the depth of modulation of the mode locked pulses. The peak power of a single mode locked green pulse near the center of the Q-switched envelope was estimated to be more than 2kw and the average green power was 6 times higher than the CW green power at an incident diode pump power of 6W. (author)

  13. Application of computer code ALMOD 3W2 in nonsymmetric transient analysis in the primary loop of nuclear power plant; Primjena programa ALMOD 3W2 u analizi nesimetricnih prijelaznih pojava u primarnom krugu nuklearne elektrane

    Energy Technology Data Exchange (ETDEWEB)

    Bencik, V [Elektrotehnicki institut ' rade Koncar' , Zagreb (Yugoslavia); Debrecin, N; Feretic, D; Kozaric, M [Elektrotehnicki fakultet, Zagreb (Yugoslavia)

    1988-07-01

    In this paper the method to calculate the nonsymetric transients in the nuclear power plant is presented. ALMOD 3W2 computer code with steam generator model GEVAP is applied to analyze partial loss of forced reactor coolant flow for NPP Krsko. (author)

  14. Czynniki ryzyka upadków i złamań kości u pacjentów chorych na reumatoidalne zapalenie stawów

    Directory of Open Access Journals (Sweden)

    Krzysztof Tomaszewski

    2010-04-01

    Full Text Available Cel pracy: Ocena czynników ryzyka i częstości występowaniaupadków i złamań kości u chorych na reumatoidalne zapaleniestawów (RZS. Materiał i metody: Do badania kwalifikowano pacjentów chorychna RZS (spełniających kryteria ACR z 1984 r.. Dane na temat stanuzdrowia zebrano na podstawie ankiety zawierającej Kwestio -nariusz Oceny Stanu Zdrowia (HAQ, pytań dotyczących chorób,przyjmowanych leków, upadków i złamań kości w okresie ostatnich12 miesięcy. Wyniki: Przebadano 167 kobiet (89,8% i 19 mężczyzn (średni wiek± SD 58,5 ±13,8 roku. Średni czas trwania choroby wynosił14,4 ±10,7 roku. Średnia wartość HAQ 1,36 ±0,76. Z grupy 186 osóbupadek przydarzył się 80 badanym (43%. U 28 chorych (35%upadek zakończył się złamaniem bądź złamaniami obwodowymi.Liczba upadków dodatnio korelowała z wynikiem HAQ (r = 0,32;p < 0,05 oraz czasem trwania choroby (r = 0,31; p < 0,05.Głównymi czynnikami ryzyka upadków w badanej grupie byłyzawroty głowy [iloraz szans (OR = 2,68], stosowanie lekówhipotensyjnych (OR = 2,27 i przeciwdepresyjnych (OR = 2,56,deformacje stóp (OR = 3,14 oraz wysoki wskaźnik HAQ(OR = 2,08. Czas trwania RZS (OR = 1,05 i wiek (OR = 1,04 praktycznienie wpływały na ryzyko upadków. Głównymi czynnikamiryzyka złamań kości w badanej grupie były osteoporoza (t-score< –2,5 (OR = 4,70, stosowanie leków hipotensyjnych (OR = 4,98,deformacje stóp (OR = 4,82, zawroty głowy (OR = 3,30 orazwysoki wskaźnik HAQ (OR = 3,12. Wnioski: Upadki są poważnym problemem w przebiegu RZS.Głównymi czynnikami sprzyjającymi upadkom i złamaniomu chorych na RZS są deformacje stóp, zawroty głowy, zażywanieleków obniżających ciśnienie tętnicze oraz wysoka wartość HAQ.

  15. Rola leptyny w regulacji metabolizmu lipidów i węglowodanów

    Directory of Open Access Journals (Sweden)

    Patrycja Gogga*

    2011-01-01

    Full Text Available Leptyna jest białkiem wydzielanym głównie przez tkankę tłuszczową, a jej stężenie we krwi jest ściśle związane z ilością zapasów energetycznych zgromadzonych w adipocytach. Jako hormon leptyna ma niezwykle szeroki zakres działania. Białko to bezpośrednio lub za pośrednictwem układu współczulnego bierze udział w regulacji metabolizmu energetycznego. Leptyna hamuje biosyntezę triacylogliceroli w wątrobie i tkance tłuszczowej, a także w mięśniach szkieletowych, obniżając tym samym ilość odkładanych w nich lipidów. W adipocytach leptyna zmniejsza ekspresję genów kodujących syntazę kwasów tłuszczowych (FAS i karboksylazę acetylo-CoA (ACC – główne enzymy szlaku biosyntezy kwasów tłuszczowych. Zwiększa z kolei ekspresję genu kodującego lipazę zależną od hormonów (HSL, co stymuluje hydrolizę triacylogliceroli w tkance tłuszczowej. Ponadto leptyna wzmaga utlenianie kwasów tłuszczowych w adipocytach, mięśniach szkieletowych oraz w mięśniu sercowym, wywołując wzrost ekspresji genów kodujących podstawowe dla tego procesu enzymy, palmitoilotransferazę karnitynową 1 (CPT1 i dehydrogenazę acylo-CoA o średniej długości łańcucha (MCAD. Wykazano również, że hormon ten zwiększa wrażliwość tkanek na insulinę i poprawia tolerancję glukozy – pod wpływem leptyny wzrasta transport glukozy do komórek oraz intensywność glikolizy.Wiadomo, że leptyna bierze udział w długoterminowej regulacji pobierania pokarmu, jednak coraz więcej badań wskazuje, że ma ona również wpływ na przemiany substratów energetycznych w tkankach obwodowych. Leptyna może zatem kontrolować homeostaz�� energetyczną organizmu wywołując zmiany metabolizmu lipidów i węglowodanów, przede wszystkim w tkance tłuszczowej i w mięśniach.

  16. Remote Power Systems for Sensors on the Northern Border

    Energy Technology Data Exchange (ETDEWEB)

    Simpson, Lin J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Kandt, Alicen J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-06-08

    The National Renewable Energy Laboratory (NREL) is working with the Department of Homeland Security (DHS) [1] to field sensors that accurately track different types of transportation across the northern border of the U.S.. To do this, the sensors require remote power so that they can be placed in the most advantageous geographical locations, often where no grid power is available. This enables the sensors to detect and track aircraft/vehicles despite natural features (e.g., mountains, ridges, valleys, trees) that often prevent standard methods (e.g., monostatic radar or visual observers) from detecting them. Without grid power, portable power systems were used to provide between 80 and 300 W continuously, even in bitter cold and when buried under feet of snow/ice. NREL provides details about the design, installation, and lessons learned from long-term deployment of a second-generation of novel power systems that used adjustable-angle photovoltaics (PV), lithium ion batteries, and fuel cells that provide power to achieve 100% up-time.

  17. Design of a New Water Load for S-band 750 kW Continuous Wave High Power Klystron Used in EAST Tokamak

    Science.gov (United States)

    Liu, Liang; Liu, Fukun; Shan, Jiafang; Kuang, Guangli

    2007-04-01

    In order to test the klystrons operated at a frequency of 3.7 GHz in a continuous wave (CW) mode, a type of water load to absorb its power up to 750 kW is presented. The distilled water sealed with an RF ceramic window is used as the absorbent. At a frequency range of 70 MHz, the VSWR (Voltage Standing Wave Ratio) is below 1.2, and the rise in temperature of water is about 30 oC at the highest power level.

  18. Analysis of ER string test thermally instrumented interconnect 80-K MLI blanket

    International Nuclear Information System (INIS)

    Daly, E.; Pletzer, R.

    1992-04-01

    An 80-K Multi Layer Insulation (MLI) blanket in the interconnect region between magnets DD0019 and DD0027 in the Fermi National Accelerator Laboratory (FNAL) ER string was instrumented with temperature sensors to obtain the steady-state temperature gradient through the blanket after string cooldown. A thermal model of the 80-K blanket assembly was constructed to analyze the steady-state temperature gradient data. Estimates of the heat flux through the 80-K MLI blanket assembly and predicted temperature gradients were calculated. The thermal behavior of the heavy polyethylene terapthalate (PET) cover layers separating the shield and inner blanket and inner and outer blankets was derived empirically from the data. The results of the analysis predict a heat flux of 0.363--0.453 W/m 2 based on the 11 sets of data. These flux values are 33--46% below the 80-K MLI blanket heat leak budget of 0.676 W/m 2 . The effective thermal resistance of the two heavy PET cover layers between the shield and inner blanket was found to be 2.1 times that of a single PET spacer layer, and the effective resistance of the two heavy PET cover layers between the inner blanket and outer blanket was found to be 7 times that of a single PET spacer layer. Based on these results, the 80-K MLI blanket assembly appears to be performing more than adequately to meet the 80-K static IR heat leak budget. However, these results should not be construed as a verification of the 80-K static IR heat leak, since no actual heat leak was measured. The results have been used to improve the empirically based model data in the 80-K MLI blanket thermal model, which has previously not included the effects of heavy PET cover layers on 80-K MLI blanket thermal performance

  19. Antimicrobial properties of analgesic kyotorphin peptides unraveled through atomic force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Marta M.B.; Franquelim, Henri G.; Torcato, Ines M. [Instituto de Medicina Molecular, Faculdade de Medicina de Lisboa, Av. Professor Egas Moniz, 1649-028 Lisboa (Portugal); Ramu, Vasanthakumar G.; Heras, Montserrat; Bardaji, Eduard R. [Laboratori d' Innovacio en Processos i Productes de Sintesi Organica (LIPPSO), Departament de Quimica, Universitat de Girona, Campus Montilivi, 17071 Girona (Spain); Castanho, Miguel A.R.B., E-mail: macastanho@fm.ul.pt [Instituto de Medicina Molecular, Faculdade de Medicina de Lisboa, Av. Professor Egas Moniz, 1649-028 Lisboa (Portugal)

    2012-04-13

    Highlights: Black-Right-Pointing-Pointer New kyotorphin derivatives have antimicrobial properties against S. aureus. Black-Right-Pointing-Pointer Atomic force microscopy show membrane disturbing effects of KTP-NH{sub 2} and IbKTP-NH{sub 2}. Black-Right-Pointing-Pointer None of the KTP derivatives are hemolytic. Black-Right-Pointing-Pointer The minimal peptidic sequence with antimicrobial activity is Tyr-Arg, if amidated. -- Abstract: Antimicrobial peptides (AMPs) are promising candidates as alternatives to conventional antibiotics for the treatment of resistant pathogens. In the last decades, new AMPs have been found from the cleavage of intact proteins with no antibacterial activity themselves. Bovine hemoglobin hydrolysis, for instance, results in AMPs and the minimal antimicrobial peptide sequence was defined as Tyr-Arg plus a positively charged amino acid residue. The Tyr-Arg dipeptide alone, known as kyotorphin (KTP), is an endogenous analgesic neuropeptide but has no antimicrobial activity itself. In previous studies new KTP derivatives combining C-terminal amidation and Ibuprofen (Ib) - KTP-NH{sub 2}, IbKTP, IbKTP-NH{sub 2} - were designed in order to improve KTP brain targeting. Those modifications succeeded in enhancing peptide-cell membrane affinity towards fluid anionic lipids and higher analgesic activity after systemic injection resulted therefrom. Here, we investigated if this affinity for anionic lipid membranes also translates into antimicrobial activity because bacteria have anionic membranes. Atomic force microscopy revealed that KTP derivatives perturbed Staphylococcus aureus membrane structure by inducing membrane blebbing, disruption and lysis. In addition, these peptides bind to red blood cells but are non-hemolytic. From the KTP derivatives tested, amidated KTP proves to be the most active antibacterial agent. The combination of analgesia and antibacterial activities with absence of toxicity is highly appealing from the clinical point of view

  20. Low-Voltage 96 dB Snapshot CMOS Image Sensor with 4.5 nW Power Dissipation per Pixel

    Directory of Open Access Journals (Sweden)

    Orly Yadid-Pecht

    2012-07-01

    Full Text Available Modern “smart” CMOS sensors have penetrated into various applications, such as surveillance systems, bio-medical applications, digital cameras, cellular phones and many others. Reducing the power of these sensors continuously challenges designers. In this paper, a low power global shutter CMOS image sensor with Wide Dynamic Range (WDR ability is presented. This sensor features several power reduction techniques, including a dual voltage supply, a selective power down, transistors with different threshold voltages, a non-rationed logic, and a low voltage static memory. A combination of all these approaches has enabled the design of the low voltage “smart” image sensor, which is capable of reaching a remarkable dynamic range, while consuming very low power. The proposed power-saving solutions have allowed the maintenance of the standard architecture of the sensor, reducing both the time and the cost of the design. In order to maintain the image quality, a relation between the sensor performance and power has been analyzed and a mathematical model, describing the sensor Signal to Noise Ratio (SNR and Dynamic Range (DR as a function of the power supplies, is proposed. The described sensor was implemented in a 0.18 um CMOS process and successfully tested in the laboratory. An SNR of 48 dB and DR of 96 dB were achieved with a power dissipation of 4.5 nW per pixel.

  1. Laser-diode pumped 40-W Yb:YAG ceramic laser.

    Science.gov (United States)

    Hao, Qiang; Li, Wenxue; Pan, Haifeng; Zhang, Xiaoyi; Jiang, Benxue; Pan, Yubai; Zeng, Heping

    2009-09-28

    We demonstrated a high-power continuous-wave (CW) polycrystalline Yb:YAG ceramic laser pumped by fiber-pigtailed laser diode at 968 nm with 400 mum fiber core. The Yb:YAG ceramic laser performance was compared for different Yb(3+) ion concentrations in the ceramics by using a conventional end-pump laser cavity consisting of two flat mirrors with output couplers of different transmissions. A CW laser output of 40 W average power with M(2) factor of 5.8 was obtained with 5 mol% Yb concentration under 120 W incident pump power. This is to the best of our knowledge the highest output power in end-pumped bulk Yb:YAG ceramic laser.

  2. Design and cost analysis of 1 kW photovoltaic system based on actual performance in Indian scenario

    Directory of Open Access Journals (Sweden)

    Shahzad Ahsan

    2016-09-01

    Full Text Available The exhaustion of conventional resources and its effect on climate requires an urgent call for the substitute power resources to convene up the current power requirement. Solar energy is an endless, unsoiled and prospective energy source among all other nonconventional energy options. As more concentration is being done on focal point for the development of renewable energy capital globally. To ascertain their viability it is necessary to do the economic and technical assessments of these resources. This paper presents designing aspects and assessments of solar PV system based on field and actual performance. The study is based on design of solar PV system and a case study based on cost analysis of 1.0 kW off-grid photovoltaic energy system installed at Jamia Millia Islamia, New Delhi (28.5616° N, 77.2802° E, and about 293 m above sea level India. Both monthly and weekly costs of energy produced by the 1 kW PV system have been calculated. In addition, the solar PV 1 kW system can give internal rate of return of about 1.714% on investment. Based on assumptions used in this study, solar 1 kW PV system of Rs. 0.9724/kWh is estimated for a project with profitable life of 25 years with no other financial support. This translates to Rs. 80,000 payment over the livelier cost of energy of 1 kWh generated by the system. However, if the financial support is more than 50% of the initial investment cost, no further payment fee is necessary to support this type of system. Basically this system has been designed for small home located at the place of availability of grid power is rare. 1 kW PV solar system is also very useful in rural areas of India. India as a subcontinent receives great amounts of solar radiation annually.

  3. Development of a 100 W, single frequency, CW Nd:YAG Laser

    International Nuclear Information System (INIS)

    Veitch, P.J.; Mudge, D.; Munch, J.; Hamilton, M.W.; Ostermeyer, M.; Hosken, D.; Brooks, A.

    2002-01-01

    Full text: High power, diode-laser-pumped, continuous wave (cw) solid-state lasers with excellent beam quality, efficiency and reliability are required for demanding applications, including gravitational wave interferometry, where current additional requirements include single frequency, low noise and Nd:YAG. Our approach is a chain of injection locked laser oscillators, theoretically capable of achieving the lowest noise possible. We use a single-frequency (100 mW) master laser to injection lock a medium-power (10 W) laser that in turn injection locks a 100 W laser. Injection locking requires an optimized, single mode, power slave laser at each stage. We shall describe the nearly completed 10 W brass-board laser, which will also be deployed at the ACIGA Test Facility at Gingin. We shall also describe our 100 W laser using a scalable diode pumping scheme, an active control of thermal lensing and a stable-unstable resonator. Initial tests showed mode control to be limited by thermal focusing and thermally induced birefringence in the Nd:YAG medium at 70 W output. Recent efforts have identified the source of the thermal lens and significantly reduced its magnitude, leading to a modified design. We shall present our latest results from the experiments to demonstrate single mode, single frequency laser at 100 W

  4. A 10-bit 80-MS/s opamp-sharing pipelined ADC with a switch-embedded dual-input MDAC

    Energy Technology Data Exchange (ETDEWEB)

    Yin Rui; Zhang Wei; Tang Zhangwen [ASIC and System State Key Laboratory, Fudan University, Shanghai 201203 (China); Liao Youchun, E-mail: zwtang@fudan.edu.cn [Ratio Microelectronics Co., Ltd, Shanghai 200433 (China)

    2011-02-15

    A 10-bit 80-MS/s opamp-sharing pipelined ADC is implemented in a 0.18-{mu}m CMOS. An opamp-sharing MDAC with a switch-embedded dual-input opamp is proposed to eliminate the non-resetting and successive-stage crosstalk problems observed in the conventional opamp-sharing technique. The ADC achieves a peak SNDR of 60.1 dB (ENOB = 9.69 bits) and a peak SFDR of 76 dB, while maintaining more than 9.6 ENOB for the full Nyquist input bandwidth. The core area of the ADC is 1.1 mm{sup 2} and the chip consumes 28 mW with a 1.8 V power supply. (semiconductor integrated circuits)

  5. Dimensionless energy confinement scaling in W7-AS

    International Nuclear Information System (INIS)

    Preuss, R.; Dose, V.

    2001-01-01

    Energy confinement in W7-AS has been analyzed in terms of dimensionally exact form free functions employing Bayesian probability theory. The confinement function was set up as a linear combination of dimensionally exact power law terms as already proposed very early by Connor and Taylor. Generation of this expansion basis is dictated by the basic plasma model which one assumes. Based upon data accumulated in W7-AS, which contains the energy content for a wide variety of variable settings, predictions for single variable scans are made. The scaling functions for density and power scans, respectively, are in quantitative agreement with data collected in W7-AS. The result of a single variable scan is therefore already hidden in the data obtained for arbitrary variable choices and can be extracted from the latter by a proper data analysis. Furthermore, the optimal model for the description of the global transport in W7-AS is identified as the collisional low beta kinetic model. (author)

  6. Dimensionless energy confinement scaling in W7-AS

    International Nuclear Information System (INIS)

    Preuss, R.; Dose, V.; Linden, W. von der

    1999-01-01

    Energy confinement in W7-AS has been analyzed in terms of dimensionally exact form free functions employing Bayesian probability theory. The confinement function was set up as a linear combination of dimensionally exact power law terms as already proposed very early by Connor and Taylor. Generation of this expansion basis is dictated by the basic plasma model which one assumes. Based upon data accumulated in W7-AS, which contains the energy content for a wide variety of variable settings, predictions for single variable scans are made. The scaling functions for density and power scans, respectively, are in quantitative agreement with data collected in W7-AS. The result of a single variable scan is therefore already hidden in the data obtained for arbitrary variable choices and can be extracted from the latter by a proper data analysis. Furthermore, the optimal model for the description of the global transport in W7-AS is identified as the collisional low beta kinetic model. (author)

  7. Characterisation of 100 kW electron beam melting gun and its adaptation as electron gun for high power DC electron accelerators

    International Nuclear Information System (INIS)

    Banerjee, Srutarshi; Bhattacharjee, Dhruva; Waghmare, Abhay; Tiwari, Rajnish; Bakhtsingh, R.I.; Dasgupta, K.; Gupta, Sachin; Prakash, Baibhaw; Jha, M.N.

    2015-01-01

    The paper deals with the characterization of the 100 kW electron beam melting gun for its adaptation in high power DC Electron Accelerators. The indigenously designed electron beam melting system at BARC is chosen for characterization. It comprises of electron gun as source of electrons, two electromagnetic focusing lenses viz. upper focusing lens and lower focusing lens for beam focusing, intermediate beam aperture for vacuum decoupling between gun region and melt zone, deflection and oscillation lens for maneuvering the beam on the melt charge and water cooled crucible that acts as a beam dump. In this system, the electron gun is designed for 40 kV and 100 kW corresponding to a maximum beam current of 2.5 A. The electron gun uses directly heated spiral tungsten filament. The operating temperature of the filament is 2800 °K. The focusing electrode and the anode profile are designed based on Pierce geometry. High Power DC Electron Accelerators require high currents of 1 A. The beam must comply with the requirement of 40 mm beam diameter and 10 mrad divergence at the exit of the electron gun. The characterization of the existing electron gun was done to find out all the beam parameters, for e.g. beam size, beam divergence, perveance etc. to be adapted or to be modified for the design of electron gun for high power DC accelerators. This paper shows limitations and the possible solutions for design of high power DC accelerators. (author)

  8. Measurement of the mass and width of the W boson

    CERN Document Server

    Abbiendi, G.; Akesson, P.F.; Alexander, G.; Anagnostou, G.; Anderson, K.J.; Asai, S.; Axen, D.; Bailey, I.; Barberio, E.; Barillari, T.; Barlow, R.J.; Batley, R.J.; Bechtle, P.; Behnke, T.; Bell, Kenneth Watson; Bell, P.J.; Bella, G.; Bellerive, A.; Benelli, G.; Bethke, S.; Biebel, O.; Boeriu, O.; Bock, P.; Boutemeur, M.; Braibant, S.; Brown, Robert M.; Burckhart, H.J.; Campana, S.; Capiluppi, P.; Carnegie, R.K.; Carter, A.A.; Carter, J.R.; Chang, C.Y.; Charlton, D.G.; Ciocca, C.; Csilling, A.; Cuffiani, M.; Dado, S.; De Roeck, A.; De Wolf, E.A.; Desch, K.; Dienes, B.; Dubbert, J.; Duchovni, E.; Duckeck, G.; Duerdoth, I.P.; Etzion, E.; Fabbri, F.; Ferrari, P.; Fiedler, F.; Fleck, I.; Ford, M.; Frey, A.; Gagnon, P.; Gary, John William; Geich-Gimbel, C.; Giacomelli, G.; Giacomelli, P.; Giunta, Marina; Goldberg, J.; Gross, E.; Grunhaus, J.; Gruwe, M.; Gunther, P.O.; Gupta, A.; Hajdu, C.; Hamann, M.; Hanson, G.G.; Harel, A.; Hauschild, M.; Hawkes, C.M.; Hawkings, R.; Hemingway, R.J.; Herten, G.; Heuer, R.D.; Hill, J.C.; Horvath, D.; Igo-Kemenes, P.; Ishii, K.; Jeremie, H.; Jovanovic, P.; Junk, T.R.; Kanzaki, J.; Karlen, D.; Kawagoe, K.; Kawamoto, T.; Keeler, R.K.; Kellogg, R.G.; Kennedy, B.W.; Kluth, S.; Kobayashi, T.; Kobel, M.; Komamiya, S.; Kramer, T.; Krasznahorkay, A.; Krieger, P.; von Krogh, J.; Kuhl, T.; Kupper, M.; Lafferty, G.D.; Landsman, H.; Lanske, D.; Lellouch, D.; Letts, J.; Levinson, L.; Lillich, J.; Lloyd, S.L.; Loebinger, F.K.; Lu, J.; Ludwig, A.; Ludwig, J.; Mader, W.; Marcellini, S.; Martin, A.J.; Mashimo, T.; Mattig, Peter; McKenna, J.; McPherson, R.A.; Meijers, F.; Menges, W.; Merritt, F.S.; Mes, H.; Meyer, Niels T.; Michelini, A.; Mihara, S.; Mikenberg, G.; Miller, D.J.; Mohr, W.; Mori, T.; Mutter, A.; Nagai, K.; Nakamura, I.; Nanjo, H.; Neal, H.A.; Nisius, R.; O'Neale, S.W.; Oh, A.; Oreglia, M.J.; Orito, S.; Pahl, C.; Pasztor, G.; Pater, J.R.; Pilcher, J.E.; Pinfold, J.; Plane, David E.; Pooth, O.; Przybycien, M.; Quadt, A.; Rabbertz, K.; Rembser, C.; Renkel, P.; Roney, J.M.; Rossi, A.M.; Rozen, Y.; Runge, K.; Sachs, K.; Saeki, T.; Sarkisyan, E.K.G.; Schaile, A.D.; Schaile, O.; Scharff-Hansen, P.; Schieck, J.; Schorner-Sadenius, T.; Schroder, Matthias; Schumacher, M.; Seuster, R.; Shears, T.G.; Shen, B.C.; Sherwood, P.; Skuja, A.; Smith, A.M.; Sobie, R.; Soldner-Rembold, S.; Spano, F.; Stahl, A.; Strom, David M.; Strohmer, R.; Tarem, S.; Tasevsky, M.; Teuscher, R.; Thomson, M.A.; Torrence, E.; Toya, D.; Tran, P.; Trigger, I.; Trocsanyi, Z.; Tsur, E.; Turner-Watson, M.F.; Ueda, I.; Ujvari, B.; Vollmer, C.F.; Vannerem, P.; Vertesi, R.; Verzocchi, M.; Voss, H.; Vossebeld, J.; Ward, C.P.; Ward, D.R.; Watkins, P.M.; Watson, A.T.; Watson, N.K.; Wells, P.S.; Wengler, T.; Wermes, N.; Wilson, G.W.; Wilson, J.A.; Wolf, G.; Wyatt, T.R.; Yamashita, S.; Zer-Zion, D.; Zivkovic, Lidija

    2006-01-01

    The mass and width of the W boson are measured using e+e- -> W+W- events from the data sample collected by the OPAL experiment at LEP at centre-of-mass energies between 170 GeV and 209 GeV. The mass (mw) and width (gw) are determined using direct reconstruction of the kinematics of W+W- -> qqbarlv and W+W- -> qqbarqqbar events. When combined with previous OPAL measurements using W+W- -> lvlv events and the dependence on mw of the WW production cross-section at threshold, the results are determined to be mw = 80.415 +- 0.042 +- 0.030 +- 0.009 GeV gw = 1.996 +- 0.096 +- 0.102 +- 0.003 GeV where the first error is statistical, the second systematic and the third due to uncertainties in the value of the LEP beam energy. By measuring mw with several different jet algorithms in the qqbarqqbar channel, a limit is also obtained on possible final-state interactions due to colour reconnection effects in W+W- -> qqbarqqbar events. The consistency of the results for the W mass and width with those inferred from other ele...

  9. Evaluation of wind power production prospective and Weibull parameter estimation methods for Babaurband, Sindh Pakistan

    International Nuclear Information System (INIS)

    Khahro, Shahnawaz Farhan; Tabbassum, Kavita; Soomro, Amir Mahmood; Dong, Lei; Liao, Xiaozhong

    2014-01-01

    Highlights: • Weibull scale and shape parameters are calculated using 5 numerical methods. • Yearly mean wind speed is 6.712 m/s at 80 m height with highest in May 9.595 m/s. • Yearly mean WPD is 310 W/m 2 and available energy density is 2716 kWh/m 2 at 80 m height. • Probability of higher wind speeds is more in spring and summer than in autumn and winter. • Estimated cost of per kWh of electricity from wind is calculated as 0.0263 US$/kWh. - Abstract: Pakistan is currently experiencing an acute shortage of energy and urgently needs new sources of affordable energy that could alleviate the misery of the energy starved masses. At present the government is increasing not only the conventional energy sources like hydel and thermal but also focusing on the immense potential of renewable energy sources like; solar, wind, biogas, waste-to-energy etc. The recent economic crisis worldwide, global warming and climate change have also emphasized the need for utilizing economic feasible energy sources having lowest carbon emissions. Wind energy, with its sustainability and low environmental impact, is highly prominent. The aim of this paper is to explore the wind power production prospective of one of the sites in south region of Pakistan. It is worth mentioning here that this type of detailed analysis is hardly done for any location in Pakistan. Wind power densities and frequency distributions of wind speed at four different altitudes along with estimated wind power expected to be generated through commercial wind turbines is calculated. Analysis and comparison of 5 numerical methods is presented in this paper to determine the Weibull scale and shape parameters for the available wind data. The yearly mean wind speed of the considered site is 6.712 m/s and has power density of 310 W/m 2 at 80 m height with high power density during April to August (highest in May with wind speed 9.595 m/s and power density 732 W/m 2 ). Economic evaluation, to exemplify feasibility

  10. Mid-infrared PbTe vertical external cavity surface emitting laser on Si-substrate with above 1 W output power

    Science.gov (United States)

    Rahim, M.; Fill, M.; Felder, F.; Chappuis, D.; Corda, M.; Zogg, H.

    2009-12-01

    Mid-infrared vertical external cavity surface emitting lasers (VECSELs) emitting above 1 W output power in pulsed mode and up to 17 mW in continuous mode at -172 °C were realized. Emission wavelength changes from 5 μm at -172 °C to 3.6 μm at 20 °C heat sink temperature. The active medium is a one wavelength thick PbTe layer grown by molecular beam epitaxy on a Si-substrate. It is followed by a 2.5 pair Pb1-yEuyTe/EuTe epitaxial Bragg mirror. The cavity is completed with an external curved Pb1-yEuyTe/BaF2 mirror. The VECSEL is optically pumped with 1.55 μm wavelength laser and In-soldered to Cu heat sink. No microstructural processing is needed.

  11. Truncated thioredoxin (Trx-80) promotes pro-inflammatory macrophages of the M1 phenotype and enhances atherosclerosis.

    Science.gov (United States)

    Mahmood, Dler Faieeq Darweesh; Abderrazak, Amna; Couchie, Dominique; Lunov, Oleg; Diderot, Vimala; Syrovets, Tatiana; Slimane, Mohamed-Naceur; Gosselet, Fabien; Simmet, Thomas; Rouis, Mustapha; El Hadri, Khadija

    2013-07-01

    Vascular cells are particularly susceptible to oxidative stress that is believed to play a key role in the pathogenesis of cardiovascular disorders. Thioredoxin-1 (Trx-1) is an oxidative stress-limiting protein with anti-inflammatory and anti-apoptotic properties. In contrast, its truncated form (Trx-80) exerts pro-inflammatory effects. Here we analyzed whether Trx-80 might exert atherogenic effects by promoting macrophage differentiation into the M1 pro-inflammatory phenotype. Trx-80 at 1 µg/ml significantly attenuated the polarization of anti-inflammatory M2 macrophages induced by exposure to either IL-4 at 15 ng/ml or IL-4/IL-13 (10 ng/ml each) in vitro, as evidenced by the expression of the characteristic markers, CD206 and IL-10. By contrast, in LPS-challenged macrophages, Trx-80 significantly potentiated the differentiation into inflammatory M1 macrophages as indicated by the expression of the M1 cytokines, TNF-α and MCP-1. When Trx-80 was administered to hyperlipoproteinemic ApoE2.Ki mice at 30 µg/g body weight (b.w.) challenged either with LPS at 30 µg/30 g (b.w.) or IL-4 at 500 ng/30 g (b.w.), it significantly induced the M1 phenotype but inhibited differentiation of M2 macrophages in thymus and liver. When ApoE2.Ki mice were challenged once weekly with LPS for 5 weeks, they showed severe atherosclerotic lesions enriched with macrophages expressing predominantly M1 over M2 markers. Such effect was potentiated when mice received daily, in addition to LPS, the Trx-80. Moreover, the Trx-80 treatment led to a significantly increased aortic lesion area. The ability of Trx-80 to promote differentiation of macrophages into the classical proinflammatory phenotype may explain its atherogenic effects in cardiovascular diseases. Copyright © 2013 Wiley Periodicals, Inc.

  12. Fiscal 2000 report on result of international joint demonstrative development of photovoltaic power generation system. Demonstrative research on photovoltaic power generation system interconnection system (Myanmar); 2000 nendo taiyoko hatsuden system kokusai kyodo jissho kaihatsu seika hokokusho. Taiyoko hatsuden keito renkei system jissho kenkyu (Myanmar)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Joint research was conducted with Myanmar on a photovoltaic power generation system interconnection system, for which fiscal 2000 results were described in this paper. Power generating facilities were set up consisting of 80kW photovoltaic, 40kW wind and 60kW diesel systems. With the photovoltaic and wind power generation connected to a small-scale power system as a ballast load, the system interconnection is formed through load adjusting equipment such as storage batteries. The hybrid system feeding is from 6 o'clock early in the morning until 23 late at night. The diesel power generation is free from restrictions. The operating method was set on system control (demand side management) by adjustment from the load side, with ballast load control employed that adjustably operates an ice machine load. The basic design was drafted in terms of a storage battery capacity of 1,000Ah and an ice machine load of 32kW. The daytime load was assumed to be 25% of the night load. On the equipment specifications set in this basic design, arrangement design was conducted for the equipment in the premises, making a land development plan and a basic construction plan including a temporary work site, construction steps, transportation and delivery of the equipment. Quantity of solar radiation and wind data were continuously observed. (NEDO)

  13. Electro-thermal modelling of polymer lithium batteries for starting period and pulse power

    Energy Technology Data Exchange (ETDEWEB)

    Baudry, P. [Electricite de France DER, Site des Renardieres, Moret-sur-Loing (France); Neri, M. [Electricite de France DER, Site des Renardieres, Moret-sur-Loing (France); Gueguen, M. [Bollore Technologies, Odet, 29 Quimper (France); Lonchampt, G. [CEA/CEREM, CENG-85X, 38 Grenoble (France)

    1995-04-01

    Since power capabilities of solid polymer lithium batteries can only be delivered above 60 C, the thermal management in electric-vehicle applications has to be carefully considered. Electro-thermal modelling of a thermally insulated 200 kg battery was performed, and electrochemical data were obtained from laboratory cell impedance measurements at 20 and 80 C. Starting at 20 C as initial working temperature, the battery reaches 40 C after 150 s of discharge in a 0.5 {Omega} resistance. At 40 C, the useful peak power is 20 kW. The energy expense for heating the battery from 20 to 40 C is 1.4 kWh, corresponding to 6% of the energy available in the battery. After a stand-by period of 24 h, the temperature decreases from 80 to 50 C, allowing efficient starting conditions. (orig.)

  14. MHD power plants - a reality of the 80's

    International Nuclear Information System (INIS)

    Pishchikov, S.

    1981-01-01

    A 300 MW MHD generator and a conventional turbogenerator of the same capacity will be used for the first MHD power block assembly projected in the USSR. The power plant's own consumption will not exceed 12% and the availability will be approximately 50%. Compared with a conventional power generating unit of a capacity of 500 MW the projected unit will provide fuel savings of at least 23%. The project is based on almost seven years long experience with the U-25 experimental MHD facility. Similar to the U-25, the MHD power plant projected will be fired with natural gas. (B.S.)

  15. MHD power plants - a reality of the 80's

    Energy Technology Data Exchange (ETDEWEB)

    Pishchikov, S

    1981-02-01

    A 300 MW MHD generator and a conventional turbogenerator of the same capacity will be used for the first MHD power block assembly projected in the USSR. The power plant's own consumption will not exceed 12% and the availability will be approximately 50%. Compared with a conventional power generating unit of a capacity of 500 MW the projected unit will provide fuel savings of at least 23%. The project is based on almost seven years long experience with the U-25 experimental MHD facility. Similar to the U-25, the MHD power plant projected will be fired with natural gas.

  16. Design and test of-80 kV snubber core assemblies for MFTF sustaining-neutral-beam power supplies

    International Nuclear Information System (INIS)

    Bishop, S.R.; Mayhall, D.J.; Wilson, J.H.; De Vore, K.R.; Ross, R.I.; Sears, R.G.

    1981-01-01

    Core snubbers, located near the neutral beam source ends of the Mirror Fusion Test Facility (MFTF) Sustaining Neutral Beam Power Supply System (SNBPSS) source cables, protect the neutral beam source extractor grid wires from overheating and sputtering during internal sparkdowns. The snubbers work by producing an induced counter-emf which limits the fault current and by absorbing the capacitive energy stored on the 80 kV source cables and power supplies. A computer program STACAL was used in snubber magnetic design to choose appropriate tape wound cores to provide 400 Ω resistance and 25 J energy absorption. The cores are mounted horizontally in a dielectric structure. The central source cable bundle passes through the snubber and terminates on three copper buses. Multilam receptacles on the buses connect to the source module jumper cables. Corona rings and shields limit electric field stresses to allow close clearances between snubbers

  17. Space power subsystem sizing

    International Nuclear Information System (INIS)

    Geis, J.W.

    1992-01-01

    This paper discusses a Space Power Subsystem Sizing program which has been developed by the Aerospace Power Division of Wright Laboratory, Wright-Patterson Air Force Base, Ohio. The Space Power Subsystem program (SPSS) contains the necessary equations and algorithms to calculate photovoltaic array power performance, including end-of-life (EOL) and beginning-of-life (BOL) specific power (W/kg) and areal power density (W/m 2 ). Additional equations and algorithms are included in the spreadsheet for determining maximum eclipse time as a function of orbital altitude, and inclination. The Space Power Subsystem Sizing program (SPSS) has been used to determine the performance of several candidate power subsystems for both Air Force and SDIO potential applications. Trade-offs have been made between subsystem weight and areal power density (W/m 2 ) as influenced by orbital high energy particle flux and time in orbit

  18. Coupling of a 2.5 kW steam reformer with a 1 kW el PEM fuel cell

    Science.gov (United States)

    Mathiak, J.; Heinzel, A.; Roes, J.; Kalk, Th.; Kraus, H.; Brandt, H.

    The University of Duisburg-Essen has developed a compact multi-fuel steam reformer suitable for natural gas, propane and butane. This steam reformer was combined with a polymer electrolyte membrane fuel cell (PEM FC) and a system test of the process chain was performed. The fuel processor comprises a prereformer step, a primary reformer, water gas shift reactors, a steam generator, internal heat exchangers in order to achieve an optimised heat integration and an external burner for heat supply as well as a preferential oxidation step (PROX) as CO purification. The fuel processor is designed to deliver a thermal hydrogen power output from 500 W to 2.5 kW. The PEM fuel cell stack provides about 1 kW electrical power. In the following paper experimental results of measurements of the single components PEM fuel cell and fuel processor as well as results of the coupling of both to form a process chain are presented.

  19. High-gain (43 dB), high-power (40 W), highly efficient multipass amplifier at 995 nm in Yb:LiYF4

    Science.gov (United States)

    Manni, Jeffrey; Harris, Dennis; Fan, Tso Yee

    2018-06-01

    A simple implementation of a multipass amplifier along with the use of a cryogenic Yb:LiYF4 (YLF) gain medium has enabled the demonstration of a bulk amplifier with an unprecedented combination of large-signal gain (43 dB), efficiency (>50% optical), average output power (40 W) and a near-diffraction-limited output beam.

  20. Experimental Studies of W-Band Accelerator Structures at High Field

    Energy Technology Data Exchange (ETDEWEB)

    Hill, Marc E

    2001-02-09

    A high-gradient electron accelerator is desired for high-energy physics research, where frequency scalings of breakdown and trapping of itinerant beamline particles dictates operation of the accelerator at short wavelengths. The first results of design and test of a high-gradient mm-wave linac with an operating frequency at 91.392 GHz (W-band) are presented. A novel approach to particle acceleration is presented employing a planar, dielectric lined waveguide used for particle acceleration. The traveling wave fields in the planar dielectric accelerator (PDA) are analyzed for an idealized structure, along with a circuit equivalent model used for understanding the structure as a microwave circuit. Along with the W-band accelerator structures, other components designed and tested are high power rf windows, high power attenuators, and a high power squeeze-type phase shifter. The design of the accelerator and its components where eased with the aide of numerical simulations using a finite-difference electromagnetic field solver. Manufacturing considerations of the small, delicate mm-wave components and the steps taken to reach a robust fabrication process are detailed. These devices were characterized under low power using a two-port vector network analyzer to verify tune and match, including measurements of the structures' fields using a bead-pull. The measurements are compared with theory throughout. Addition studies of the W-band structures were performed under high power utilizing a 11.424 GHz electron linac as a current source. Test results include W-band power levels of 200 kW, corresponding to fields in the PDA of over 20 MV/m, a higher gradient than any collider. Planar accelerator devices naturally have an rf quadrupole component of the accelerating field. Presented for the first time are the measurements of this effect.

  1. Effective Surfactants Blend Concentration Determination for O/W Emulsion Stabilization by Two Nonionic Surfactants by Simple Linear Regression.

    Science.gov (United States)

    Hassan, A K

    2015-01-01

    In this work, O/W emulsion sets were prepared by using different concentrations of two nonionic surfactants. The two surfactants, tween 80(HLB=15.0) and span 80(HLB=4.3) were used in a fixed proportions equal to 0.55:0.45 respectively. HLB value of the surfactants blends were fixed at 10.185. The surfactants blend concentration is starting from 3% up to 19%. For each O/W emulsion set the conductivity was measured at room temperature (25±2°), 40, 50, 60, 70 and 80°. Applying the simple linear regression least squares method statistical analysis to the temperature-conductivity obtained data determines the effective surfactants blend concentration required for preparing the most stable O/W emulsion. These results were confirmed by applying the physical stability centrifugation testing and the phase inversion temperature range measurements. The results indicated that, the relation which represents the most stable O/W emulsion has the strongest direct linear relationship between temperature and conductivity. This relationship is linear up to 80°. This work proves that, the most stable O/W emulsion is determined via the determination of the maximum R² value by applying of the simple linear regression least squares method to the temperature-conductivity obtained data up to 80°, in addition to, the true maximum slope is represented by the equation which has the maximum R² value. Because the conditions would be changed in a more complex formulation, the method of the determination of the effective surfactants blend concentration was verified by applying it for more complex formulations of 2% O/W miconazole nitrate cream and the results indicate its reproducibility.

  2. A high-power versatile wireless power transfer for biomedical implants.

    Science.gov (United States)

    Jiang, Hao; Zhang, Jun Min; Liou, Shy Shenq; Fechter, Richard; Hirose, Shinjiro; Harrison, Michael; Roy, Shuvo

    2010-01-01

    Implantable biomedical actuators are highly desired in modern medicine. However, how to power up these biomedical implants remains a challenge since most of them need more than several hundreds mW of power. The air-core based radio-frequency transformer (two face-to-face inductive coils) has been the only non-toxic and non-invasive power source for implants for the last three decades [1]. For various technical constraints, the maximum delivered power is limited by this approach. The highest delivered power reported is 275 mW over 1 cm distance [2]. Also, the delivered power is highly vulnerable to the coils' geometrical arrangement and the electrical property of the medium around them. In this paper, a novel rotating-magnets based wireless power transfer that can deliver ∼10 W over 1 cm is demonstrated. The delivered power is significantly higher than the existing start-of-art. Further, the new method is versatile since there is no need to have the impedance matching networks that are highly susceptible to the operating frequency, the coil arrangement and the environment.

  3. Primarily Experimental Results for a W Wire Array Z Pinch

    International Nuclear Information System (INIS)

    Kuai Bin; Aici, Qiu; Wang Liangping; Zeng Zhengzhong; Wang Wensheng; Cong Peitian; Gai Tongyang; Wei Fuli; Guo Ning; Zhang Zhong

    2006-01-01

    Primarily experimental results are given for a W wire array Z pinch imploded with up to 2 MA in 100 ns on a Qiangguang-I pulsed power generator. The configuration and parameters of the generator, the W wire array load assembly and the diagnostic system for the experiment are described. The total X-ray energy has been obtained with a averaged power of X-ray radiation of 1.28 TW

  4. Efficient Second Harmonic Generation in 3D Nonlinear Optical-Lattice-Like Cladding Waveguide Splitters by Femtosecond Laser Inscription.

    Science.gov (United States)

    Nie, Weijie; Jia, Yuechen; Vázquez de Aldana, Javier R; Chen, Feng

    2016-02-29

    Integrated photonic devices with beam splitting function are intriguing for a broad range of photonic applications. Through optical-lattice-like cladding waveguide structures fabricated by direct femtosecond laser writing, the light propagation can be engineered via the track-confined refractive index profiles, achieving tailored output beam distributions. In this work, we report on the fabrication of 3D laser-written optical-lattice-like structures in a nonlinear KTP crystal to implement 1 × 4 beam splitting. Second harmonic generation (SHG) of green light through these nonlinear waveguide beam splitter structures provides the capability for the compact visible laser emitting devices. With Type II phase matching of the fundamental wavelength (@ 1064 nm) to second harmonic waves (@ 532 nm), the frequency doubling has been achieved through this three-dimensional beam splitter. Under 1064-nm continuous-wave fundamental-wavelength pump beam, guided-wave SHG at 532 nm are measured with the maximum power of 0.65 mW and 0.48 mW for waveguide splitters (0.67 mW and 0.51 mW for corresponding straight channel waveguides), corresponding to a SH conversion efficiency of approximately ~14.3%/W and 13.9%/W (11.2%/W, 11.3%/W for corresponding straight channel waveguides), respectively. This work paves a way to fabricate compact integrated nonlinear photonic devices in a single chip with beam dividing functions.

  5. Automation methodologies and large-scale validation for G W : Towards high-throughput G W calculations

    Science.gov (United States)

    van Setten, M. J.; Giantomassi, M.; Gonze, X.; Rignanese, G.-M.; Hautier, G.

    2017-10-01

    The search for new materials based on computational screening relies on methods that accurately predict, in an automatic manner, total energy, atomic-scale geometries, and other fundamental characteristics of materials. Many technologically important material properties directly stem from the electronic structure of a material, but the usual workhorse for total energies, namely density-functional theory, is plagued by fundamental shortcomings and errors from approximate exchange-correlation functionals in its prediction of the electronic structure. At variance, the G W method is currently the state-of-the-art ab initio approach for accurate electronic structure. It is mostly used to perturbatively correct density-functional theory results, but is, however, computationally demanding and also requires expert knowledge to give accurate results. Accordingly, it is not presently used in high-throughput screening: fully automatized algorithms for setting up the calculations and determining convergence are lacking. In this paper, we develop such a method and, as a first application, use it to validate the accuracy of G0W0 using the PBE starting point and the Godby-Needs plasmon-pole model (G0W0GN @PBE) on a set of about 80 solids. The results of the automatic convergence study utilized provide valuable insights. Indeed, we find correlations between computational parameters that can be used to further improve the automatization of G W calculations. Moreover, we find that G0W0GN @PBE shows a correlation between the PBE and the G0W0GN @PBE gaps that is much stronger than that between G W and experimental gaps. However, the G0W0GN @PBE gaps still describe the experimental gaps more accurately than a linear model based on the PBE gaps. With this paper, we hence show that G W can be made automatic and is more accurate than using an empirical correction of the PBE gap, but that, for accurate predictive results for a broad class of materials, an improved starting point or some

  6. Operational performance of the development of a 15 kW parabolic trough mid-temperature solar receiver/reactor for hydrogen production

    International Nuclear Information System (INIS)

    Hong, Hui; Liu, Qibin; Jin, Hongguang

    2012-01-01

    Highlights: ► A 15 kW solar chemical receiver/reactor for hydrogen production was developed. ► The solar thermochemical efficiency of the receiver/reactor was in the range of 20–28%. ► Hydrogen production exceeding 80% was achieved. ► The research results extend the application of mid-temperature solar thermal energy. -- Abstract: In this paper, we report the operational performance and energy conversion efficiency of a developed 15 kW solar chemical receiver/reactor for hydrogen production. A concentrated solar heat of around 200–300 °C was utilized to provide process heat to drive methanol steam reforming. A modified 15 kW direct-irradiation solar reactor coupled with a linear receiver positioned along the focal line of a one-axis parabolic trough concentrator was used. The experiments were conducted from 200 to 300 °C under a mean solar flux of 300–800 W/m 2 and a reactant feeding rate of 6 kg/h. Reactants were continuously fed, and the attained conversion rate of methanol was more than 70% at 700 W/m 2 . The typical solar thermochemical efficiency of solar thermal energy converted into chemical energy was in the 20–28% range. The overall energy efficiency of input solar power conversion into chemical energy reached up to 17% and may be further increased by improving solar field efficiency. Hydrogen production exceeding 80% was achieved. In addition, preliminary economic evaluation was performed, and methods for further improvement were proposed. This paper proves that solar hydrogen production is feasible by combining solar thermal energy with alternative fuel at around 200–300 °C, which is much lower than the temperature of other solar thermochemical processes. This may offer an economic approach to solar fuel production and extend the application of mid-temperature solar thermal energy.

  7. W-band push—push monolithic frequency doubler in 1-μm InP DHBT technology

    International Nuclear Information System (INIS)

    Yao Hongfei; Wang Xiantai; Wu Danyu; Su Yongbo; Cao Yuxiong; Ge Ji; Ning Xiaoxi; Jin Zhi

    2013-01-01

    A W-band frequency doubler MMIC is designed and fabricated using 1-μm InP DHBT technology. Active balun is employed to transform the single-ended signal into differential output. Push—push configuration loaded with harmonic resonant network is utilized to acquire the second harmonic frequency. A multi-stage differential structure improves the conversion gain and suppresses the fundamental frequency. The MMIC occupies an area of 0.55 × 0.5 mm 2 with 18 DHBTs integrated. Measurements show that the output power is above 5.8 dBm with the suppression of fundamental frequency below −16 dBc and the conversion gain above 4.7 dB over 75–80 GHz. (semiconductor integrated circuits)

  8. Simulation of fuel rods vibration in power reactors by vibration of tape coated with cadmium

    International Nuclear Information System (INIS)

    Holland, L.

    1982-01-01

    The circulation of cooling water in light water power reactor makes a vibration in internal components. The monitoring of those vibrations is necessary aiming to the safety use of reactors. Aiming at study those vibrations a neutron absorber, type vibratory tape was introduced in the core of a research reactor type Pulstar, operating at 80 W of power. The induced power variations were measured with an ionization chamber put besides the reactor core. The detector signal was recorded and analysed in a PDP-11 computer. The analysis of the results show that the power density of the detector signal, and thus, the power reactor, increase in the O-25 Hz range with an increase in the pulse height vibration. (E.G.) [pt

  9. Research on Power Factor Correction Boost Inductor Design Optimization – Efficiency vs. Power Density

    DEFF Research Database (Denmark)

    Li, Qingnan; Andersen, Michael A. E.; Thomsen, Ole Cornelius

    2011-01-01

    Nowadays, efficiency and power density are the most important issues for Power Factor Correction (PFC) converters development. However, it is a challenge to reach both high efficiency and power density in a system at the same time. In this paper, taking a Bridgeless PFC (BPFC) as an example......, a useful compromise between efficiency and power density of the Boost inductors on 3.2kW is achieved using an optimized design procedure. The experimental verifications based on the optimized inductor are carried out from 300W to 3.2kW at 220Vac input....

  10. 47 CFR 80.659 - Technical requirements.

    Science.gov (United States)

    2010-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Maritime Support Stations § 80.659 Technical requirements. The authorized frequency tolerance, class of emission, bandwidth, and transmitter power for maritime support stations are contained...

  11. Electron paramagnetic resonance and electron-nuclear double-resonance study of Ti{sup 3+} centres in KTiOPO{sub 4}

    Energy Technology Data Exchange (ETDEWEB)

    Setzler, S D [BAE Systems, Nashua, NH 03061 (United States); Stevens, K T [Northrop Grumman, Space Technology, Synoptics, Charlotte, NC 28273 (United States); Fernelius, N C [Air Force Research Laboratory, Materials and Manufacturing Directorate, AFRL/MLPSO, Wright-Patterson AFB, OH 45433 (United States); Scripsick, M P [Nova Phase, Newton, NJ 07860 (United States); Edwards, G J [Department of Physics, West Virginia University, Morgantown, WV 26506 (United States); Halliburton, L E [Department of Physics, West Virginia University, Morgantown, WV 26506 (United States)

    2003-06-18

    Electron paramagnetic resonance and electron-nuclear double resonance have been used to characterize four Ti{sup 3+} centres in undoped crystals of potassium titanyl phosphate (KTiOPO{sub 4} or KTP). These 3d{sup 1} defects (S = 1/2) are produced by ionizing radiation (either 60 kV x-rays or 355 nm photons from a tripled Nd:YAG laser), and form when the regular Ti{sup 4+} ions in the crystal trap an electron. Two of these trapped-electron centres are only observed in hydrothermally grown KTP and the other two are dominant in flux-grown KTP. Both of the Ti{sup 3+} centres in hydrothermally grown crystals have a neighbouring proton (i.e. an OH{sup -} molecule). In the flux-grown crystals, one of the Ti{sup 3+} centres is adjacent to an oxygen vacancy and the other centre is tentatively attributed to a self-trapped electron (i.e. a Ti{sup 3+} centre with no stabilizing entity nearby). The g matrix and phosphorus hyperfine matrices are determined for all four Ti{sup 3+} centres, and the proton hyperfine matrix is determined for the two centres associated with OH{sup -} ions. These Ti{sup 3+} centres contribute to the formation of the grey tracks often observed in KTP crystals used to generate the second harmonic of high-power, near-infrared lasers.

  12. NEDO Forum 2000. Solar technology development session (photovoltaic power generation system and our living); Taiyoko gijutsu kaihatsu session. Taiyoko hatsuden system to watashi tachi no kurashi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-09-01

    The following themes were presented at the present session: (1) energy and environmental problems, and expectation to the photovoltaic power generation system, (2) our living and photovoltaic power generation, and (3) energy policies of Kobe Municipality based on lessons from the earthquake disaster. Item (1) describes: if the total electric power obtained in 20 years from the photovoltaic power generation system of 3 kW output for residential houses is converted into amount of petroleum consumed by thermal power plants, it corresponds to about 850 twenty-liter polyethylene tanks; to build a photovoltaic power generation system, energy corresponding to about 100 polyethylene tanks is used; therefore, subtraction results in saving of about 750 tanks; ordinary houses discharge about 3,500 kg of CO2 annually; and the photovoltaic power generation system serves to reduce about 1,000 kg of CO2 emission annually. Item (2) describes: in markets in 2010, more than 80% of the power generation system is served for housing; profitable price of power generation value is about 55/kW; more than 50% of the value is occupied by the value for other than power generation; and more than 80% of the system for housing will be of roof-material type in 2005. Item (3) introduces the energy diversification taken by Kobe Municipality after the earthquake disaster, and the energy policies, including the 'life spot' policy. (NEDO)

  13. Impact of size and distribution of installed PV power in E-W direction on the level in which selected consumers’ energy needs were met

    OpenAIRE

    Necka Krzysztof; Latala Hubert; Kurpaska Sławomir; Knaga Jarosław; Karbowniczakʼ Anna

    2018-01-01

    The aim of the study was to analyse the energy needs of selected consumers and to select the PV installed capacity in the east and west panels orientation (E-W). The analysis was carried out for two variants. The first concerned the impact of the installation power of a PV source on the contracted power in its symmetric east and west position. The second variant was the result of previous observations and studies of the authors of this paper. Thus, in this variant, the unbalanced power of PV ...

  14. Zachowania zdrowotne studentów Dietetyki = Health behaviors of students of Dietetics

    Directory of Open Access Journals (Sweden)

    Magdalena Weber-Rajek

    2016-06-01

    6.        Uniwersytet Mikołaja Kopernika w Toruniu   Słowa kluczowe: zachowania zdrowotne, studenci. Key words: health behaviors, students.     Streszczenie Bardzo ważną rolę w procesie ochrony zdrowia jest styl życia człowieka – jego nawyki oraz wzorce postępowania. Celem badań była ocena zachowań zdrowotnych studentów kierunku Dietetyka. Grupę badawczą (Grupa I stanowiło 80 studentów kierunku Dietetyka. Grupę porównawczą (Grupa II stanowiło 70 studentów kierunków „niemedycznych” (kierunki inżynierskie. W grupie studentów Dietetyki uzyskano wysoki poziom zachowań zdrowotnych. Najwyższy poziom zachowań zdrowotnych uzyskano w kategorii „prawidłowe nawyki żywieniowe”. Studenci kierunku Dietetyka uzyskali wyższe wyniki zachowań zdrowotnych od studentów kierunków inżynierskich. Wprowadzanie programów promocji zdrowia i edukacji zdrowotnej powinno objąć wszystkie kierunki studiów, tym bardziej, że wczesna dorosłość jest najlepszym okresem dla osiągnięcia długotrwałych korzyści z wyboru zdrowego trybu życia.       Summary Very important role in the protection of health is a lifestyle - habits and patterns of conduct. The aim of the study was to assess health behaviors of Dietetics students. The research group (Group I conducted of 80 students of Dietetics. The control group (Group II conducted of 70 students of non-medical (in engineering. In the group of Dietetic student achieved a high level of health behaviors. The highest level of health behaviors was achieved in the category of "nutrition habits." Students of Dietetics scored higher health behavior of engineering students. Entering programs of health promotion and health education should be extended to all fields of study, especially that early adulthood is the best time to achieve long-term benefits of a healthy lifestyle choice.

  15. Circuit design and simulation of a HV-supply controlling the power of 140 GHz 1 MW gyrotrons for ECRH on W7-X

    International Nuclear Information System (INIS)

    Brand, P.; Mueller, G.A.

    2003-01-01

    For plasma heating by ECR in the Stellarator W7-X under construction, 140 GHz gyrotrons with 1 MW cw output power are under development. These tubes have a voltage depressed collector for electron energy recovery. Each gyrotron is fed by two high-voltage sources: a high-power supply for driving the electron beam and a precision low-power supply for beam acceleration. In addition, a protection system with a thyratron crowbar for fast power removal in case of gyrotron arcing is installed. The low-power high-voltage source for beam acceleration is realized by a high-voltage servo-amplifier driving the depression voltage such that the influence of the voltage noise of the main high-power supply on the acceleration voltage is suppressed by feed-back control of the amplifier. Design and simulation of the servo-amplifier by PSpice is presented

  16. 10-kW-class YAG laser application for heavy components

    Science.gov (United States)

    Ishide, Takashi; Tsubota, S.; Nayama, Michisuke; Shimokusu, Yoshiaki; Nagashima, Tadashi; Okimura, K.

    2000-02-01

    The authors have put the YAG laser of the kW class to practical use for repair welding of nuclear power plant steam generator heat exchanger tubes, all-position welding of pipings, etc. This paper describes following developed methods and systems of high power YAG laser processing. First, we apply the 6 kW to 10 kW YAG lasers for welding and cutting in heavy components. The beam guide systems we have used are optical fibers which core diameter is 0.6 mm to 0.8 mm and its length is 200 m as standard one. Using these system, we can get the 1 pass penetration of 15 mm to 20 mm and multi pass welding for more thick plates. Cutting of 100 mm thickness plate data also described for dismantling of nuclear power plants. In these systems we carried out the in-process monitoring by using CCD camera image processing and monitoring fiber which placed coaxial to the YAG optical lens system. In- process monitoring by the monitoring fiber, we measured the light intensity from welding area. Further, we have developed new hybrid welding with the TIG electrode at the center of lens for high power. The hybrid welding with TIG-YAG system aims lightening of welding groove allowances and welding of high quality. Through these techniques we have applied 7 kW class YAG laser for welding in the components of nuclear power plants.

  17. Enhanced saturation magnetization of Fe{sub 3}Si nanodot-embedded Fe{sub 80}Si{sub 17}Nb{sub 3} flexible film for efficient wireless power transfer

    Energy Technology Data Exchange (ETDEWEB)

    Pai, Yi-Hao, E-mail: paiyihao@mail.ndhu.edu.tw; Yan, Zih-Yu; Fu, Ping-Hao

    2013-07-15

    An efficient magnetically coupled resonance response is performed using an iron silicide-based nanostructured magnetoelectric material with high saturation magnetization for the wireless charging of battery-powered consumer electronics. With 500 °C annealing, the self-assembled Fe{sub 3}Si nanodots buried in the Fe{sub 80}Si{sub 17}Nb{sub 3} host matrix with (220) lattice spacing of 1.99 Å corresponding to a volume density of 8.96 × 10{sup 16} cm{sup 3}, can be obtained and a maximum saturation magnetization of 244 emu g{sup −1} achieved. The return loss of the antenna will be tuned to match the designed frequency with greater attenuated intensity (−0.39 dB) and a relatively narrow bandwidth (6 kHz) when the Fe{sub 3}Si nanodot-embedded Fe{sub 80}Si{sub 17}Nb{sub 3} sample is placed in a WiTricity system. An efficient wireless power transfer can be created and improved from 47.5% to 97.3%. The associated coil and loop antenna resonators are significantly readjusted to match the power transfer by putting this nanostructured magnetoelectric material in a WiTricity system. - Highlights: • The saturation magnetization is effective enhancement in the presence of Fe{sub 3}Si nanodot buried in the Fe{sub 80}Si{sub 17}Nb{sub 3}. • A saturation magnetization of 244 emu g{sup −1} is proposed for high-efficiency wireless power transfer. • The return loss of the antenna will be tuned to match the designed frequency. • Such a wireless power transfer can be enhanced efficiency up to 97.3%.

  18. A ZnGeP{sub 2} Optical Parametric Oscillator with Mid-IR Output Power 3 W Pumped by a Tm, Ho:GdVO{sub 4} Laser

    Energy Technology Data Exchange (ETDEWEB)

    Bao-Quan, Yao; Guo-Li, Zhu; You-Lun, Ju; Yue-Zhu, Wang [National Key Laboratory of Tunable Laser Technology, Harbin Institute of Technology, Harbin 150080 (China)

    2009-02-15

    We report an efficient mid-infrared optical parametric oscillator (OPO) pumped by a pulsed Tm,Ho-codoped GdVO4 laser. The 10-W Tm,Ho:GdVO4 laser pumped by a 801 nm diode produces 20ns pulses with a repetition rate of 10kHz at wavelength of 2.048 {mu}m. The ZnGeP{sub 2} (ZGP) OPO produces 15-ns pulses in the spectral regions 3.65-3.8 {mu}m and 4.45-4.65 {mu}m simultaneously. More than 3 W of mid-IR output power can be generated with a total OPO slope efficiency greater than 58% corresponding to incident 2 {mu}m pump power. The diode laser pump to mid-IR optical conversion efficiency is about 12%.

  19. Performance of a single nutating disk engine in the 2 to 500 kW power range

    International Nuclear Information System (INIS)

    Korakianitis, T.; Boruta, M.; Jerovsek, J.; Meitner, P.L.

    2009-01-01

    A new type of internal combustion engine with distinct advantages over conventional piston-engines and gas turbines in small power ranges is presented. The engine has analogies with piston engine operation, but like gas turbines it has dedicated spaces and devices for compression, burning and expansion. The engine operates on a modified limited-pressure thermodynamic cycle. The core of the engine is a nutating non-rotating disk, with the center of its hub mounted in the middle of a Z-shaped shaft. The two ends of the shaft rotate, while the disk nutates. The motion of the disk circumference prescribes a portion of a sphere. In the single-disk configuration a portion of the surface area of the disk is used for intake and compression, a portion is used to seal against a center casing, and the remaining portion is used for expansion and exhaust. The compressed air is admitted to an external accumulator, and then into an external combustion chamber before it is admitted to the power side of the disk. The external combustion chamber enables the engine to operate on a variable compression ratio cycle. Variations in cycle temperature ratio and compression ratio during normal operation enable the engine to effectively become a variable-cycle engine, allowing significant flexibility for optimizing efficiency or power output. The thermal efficiency is similar to that of medium sized diesel engines. For the same engine volume and weight this engine produces approximately twice the power of a two-stroke engine and four times the power of a four-stroke engine. The computed sea-level engine performance at design and off-design conditions in the 2 to 500 kW power range is presented.

  20. Back to the 80s

    CERN Multimedia

    Fitness Club

    2010-01-01

    The fitness club is organizing a “Back to the 80s Party” in aid of the Haiti earthquake appeal on Saturday 26.06.2010 in the Pump Room.   There’s an 80s theme, so our pro DJ will be spinning 80s tunes (all tastes catered for), Morpho will be powering the visuals and the car club will be cooking-up a bbq in case you’re peckish. Fancy dress 1980s style is welcome, though not obligatory and it kicks off just after 'music on the lawn' finishes at 20.30. Its open to anyone working at CERN, friends and family. There’s a limited number of tickets and it’s entrance by ticket only, we are selling them on Thurs lunchtimes in R1 12.15 – 13.30 for 5CHF. For more information contact fitness.club@cern.ch.

  1. Autonomously managed high power systems

    International Nuclear Information System (INIS)

    Weeks, D.J.; Bechtel, R.T.

    1985-01-01

    The need for autonomous power management capabilities will increase as the power levels of spacecraft increase into the multi-100 kW range. The quantity of labor intensive ground and crew support consumed by the 9 kW Skylab cannot be afforded in support of a 75-300 kW Space Station or high power earth orbital and interplanetary spacecraft. Marshall Space Flight Center is managing a program to develop necessary technologies for high power system autonomous management. To date a reference electrical power system and automation approaches have been defined. A test facility for evaluation and verification of management algorithms and hardware has been designed with the first of the three power channel capability nearing completion

  2. 47 CFR 80.873 - VHF radiotelephone transmitter.

    Science.gov (United States)

    2010-10-01

    ...) The transmitter must deliver a carrier power between 8 and 25 watts into a 50 ohm effective resistance... 50 ohms effective resistance over the frequency band specified in § 80.871(d). An individual...

  3. The System 80+ Standard Plant design control document. Volume 11

    International Nuclear Information System (INIS)

    1997-01-01

    This Design Control Document (DCD) is a repository of information comprising the System 80+trademark Standard Plant Design. The DCD also provides that design-related information to be incorporated by reference in the design certification rule for the System 80+ Standard Plant Design. Applicants for a combined license pursuant to 10 CFR 52 must ensure that the final Design Certification Rule and the associated Statements of Consideration are used when making all licensing decisions relevant to the System 80+ Standard Plant Design. The Design Control Document contains the DCD introduction, The Certified Design Material (CDM) [i.e., ''Tier 1''] and the Approved Design Material (ADM) [i.e., ''Tier 2''] for the System 80+ Standard Plant Design. The CDM includes the following sections: (1) Introductory material; (2) Certified Design Material for System 80+ systems and structures; (3) Certified Design Material for non-system-based aspects of the System 80+ Certified design; (4) Interface requirements; and (5) Site parameters. The ADM, to the extent applicable for the System 80+ Standard Plant Design, includes: (1) the information required for the final safety analysis report under 20 CFR 50.34; (2) other relevant information required by 10 CFR 52.47; and (3) emergency operations guidelines. This volume covers parts 6 and 7 and appendix 7A for section 7 (Instrumentation and Control) of the ADM Design and Analysis. The topics covered by these are: other systems required for safety; control systems not required by safety; and CMF evaluation of limiting faults. Parts 1--3 of section 8 (Electric Power) of the ADM are also included in this volume. Topics covered by these parts are: introduction; offsite power system; and onsite power system

  4. Analysis of the Opportunity for an Increase in the Thermal Power of Power Generating Units of Nuclear Power Plants (Part 1)

    OpenAIRE

    Chernousenko, Olga Yuriivna; Nikulenkova, Tetiana Volodymyrivna; Nikulenkov, Anatolii Hennadiiovych

    2017-01-01

    For Ukraine the realization of available reserves to increase the power of operating power units of nuclear plants is a vital problem the solution of which would allow us to increase electric power output. A special role is also played by economic priorities; in particular an increase in power by 1 kW is ten times cheaper in comparison with the construction of 1 kW of new power facilities. One more factor is the world experience in the field of an increase in the thermal power of operating po...

  5. Pair-Production of W Bosons in $e^+ e^-$ Interactions at $\\sqrt{s}$ = 161 GeV

    CERN Document Server

    Acciarri, M; Aguilar-Benítez, M; Ahlen, S P; Alpat, B; Alcaraz, J; Alemanni, G; Allaby, James V; Aloisio, A; Alverson, G; Alviggi, M G; Ambrosi, G; Anderhub, H; Andreev, V P; Angelescu, T; Anselmo, F; Antreasyan, D; Arefev, A; Azemoon, T; Aziz, T; Bagnaia, P; Baksay, L; Banerjee, S; Banicz, K; Barillère, R; Barone, L; Bartalini, P; Baschirotto, A; Basile, M; Battiston, R; Bay, A; Becattini, F; Becker, U; Behner, F; Berdugo, J; Berges, P; Bertucci, B; Betev, B L; Bhattacharya, S; Biasini, M; Biland, A; Bilei, G M; Blaising, J J; Blyth, S C; Bobbink, Gerjan J; Böck, R K; Böhm, A; Borgia, B; Bourilkov, D; Bourquin, Maurice; Braccini, S; Branson, J G; Brigljevic, V; Brock, I C; Buffini, A; Buijs, A; Burger, J D; Burger, W J; Busenitz, J K; Button, A M; Cai, X D; Campanelli, M; Capell, M; Cara Romeo, G; Caria, M; Carlino, G; Cartacci, A M; Casaus, J; Castellini, G; Cavallari, F; Cavallo, N; Cecchi, C; Cerrada-Canales, M; Cesaroni, F; Chamizo-Llatas, M; Chan, A; Chang, Y H; Chaturvedi, U K; Chekanov, S V; Chemarin, M; Chen, A; Chen, G; Chen, G M; Chen, H F; Chen, H S; Chéreau, X J; Chiefari, G; Chien, C Y; Choi, M T; Cifarelli, Luisa; Cindolo, F; Civinini, C; Clare, I; Clare, R; Cohn, H O; Coignet, G; Colijn, A P; Colino, N; Commichau, V; Costantini, S; Cotorobai, F; de la Cruz, B; Csilling, Akos; Dai, T S; D'Alessandro, R; De Asmundis, R; Degré, A; Deiters, K; Della Volpe, D; Denes, P; De Notaristefani, F; DiBitonto, Daryl; Diemoz, M; Van Dierendonck, D N; Di Lodovico, F; Dionisi, C; Dittmar, Michael; Dominguez, A; Doria, A; Dova, M T; Drago, E; Duchesneau, D; Duinker, P; Durán, I; Dutta, S; Easo, S; Efremenko, Yu V; El-Mamouni, H; Engler, A; Eppling, F J; Erné, F C; Ernenwein, J P; Extermann, Pierre; Fabre, M; Faccini, R; Falciano, S; Favara, A; Fay, J; Fedin, O; Felcini, Marta; Fenyi, B; Ferguson, T; Fernández, D; Ferroni, F; Fesefeldt, H S; Fiandrini, E; Field, J H; Filthaut, Frank; Fisher, P H; Forconi, G; Fredj, L; Freudenreich, Klaus; Furetta, C; Galaktionov, Yu; Ganguli, S N; García-Abia, P; Gau, S S; Gentile, S; Gheordanescu, N; Giagu, S; Goldfarb, S; Goldstein, J; Gong, Z F; Gougas, Andreas; Gratta, Giorgio; Grünewald, M W; Gupta, V K; Gurtu, A; Gutay, L J; Hartmann, B; Hasan, A; Hatzifotiadou, D; Hebbeker, T; Hervé, A; Van Hoek, W C; Hofer, H; Hoorani, H; Hou, S R; Hu, G; Innocente, Vincenzo; Jenkes, K; Jin, B N; Jones, L W; de Jong, P; Josa-Mutuberria, I; Kasser, A; Khan, R A; Kamrad, D; Kamyshkov, Yu A; Kapustinsky, J S; Karyotakis, Yu; Kaur, M; Kienzle-Focacci, M N; Kim, D; Kim, J K; Kim, S C; Kim, Y G; Kinnison, W W; Kirkby, A; Kirkby, D; Kirkby, Jasper; Kiss, D; Kittel, E W; Klimentov, A; König, A C; Korolko, I; Koutsenko, V F; Krämer, R W; Krenz, W; Kunin, A; Ladrón de Guevara, P; Laktineh, I; Landi, G; Lapoint, C; Lassila-Perini, K M; Laurikainen, P; Lebeau, M; Lebedev, A; Lebrun, P; Lecomte, P; Lecoq, P; Le Coultre, P; Lee Jae Sik; Lee, K Y; Le Goff, J M; Leiste, R; Leonardi, E; Levchenko, P M; Li Chuan; Lieb, E H; Lin, W T; Linde, Frank L; Lista, L; Liu, Z A; Lohmann, W; Longo, E; Lu, W; Lü, Y S; Lübelsmeyer, K; Luci, C; Luckey, D; Luminari, L; Lustermann, W; Ma Wen Gan; Maity, M; Majumder, G; Malgeri, L; Malinin, A; Maña, C; Mangeol, D J J; Mangla, S; Marchesini, P A; Marin, A; Martin, J P; Marzano, F; Massaro, G G G; McNally, D; McNeil, R R; Mele, S; Merola, L; Meschini, M; Metzger, W J; Von der Mey, M; Mi, Y; Mihul, A; Van Mil, A J W; Mirabelli, G; Mnich, J; Molnár, P; Monteleoni, B; Moore, R; Morganti, S; Moulik, T; Mount, R; Müller, S; Muheim, F; Muijs, A J M; Nagy, E; Nahn, S; Napolitano, M; Nessi-Tedaldi, F; Newman, H; Niessen, T; Nippe, A; Nisati, A; Nowak, H; Opitz, H; Organtini, G; Ostonen, R; Pandoulas, D; Paoletti, S; Paolucci, P; Park, H K; Pascale, G; Passaleva, G; Patricelli, S; Paul, T; Pauluzzi, M; Paus, C; Pauss, Felicitas; Peach, D; Pei, Y J; Pensotti, S; Perret-Gallix, D; Petersen, B; Petrak, S; Pevsner, A; Piccolo, D; Pieri, M; Pinto, J C; Piroué, P A; Pistolesi, E; Plyaskin, V; Pohl, M; Pozhidaev, V; Postema, H; Produit, N; Prokofev, D; Prokofiev, D O; Rahal-Callot, G; Rancoita, P G; Rattaggi, M; Raven, G; Razis, P A; Read, K; Ren, D; Rescigno, M; Reucroft, S; Van Rhee, T; Riemann, S; Riles, K; Ro, S; Robohm, A; Rodin, J; Rodríguez-Calonge, F J; Roe, B P; Romero, L; Rosier-Lees, S; Rosselet, P; Van Rossum, W; Roth, S; Rubio, Juan Antonio; Rykaczewski, H; Salicio, J; Sánchez, E; Sanders, M P; Santocchia, A; Sarakinos, M E; Sarkar, S; Sassowsky, M; Schäfer, C; Shchegelskii, V; Schmidt-Kärst, S; Schmitz, D; Schmitz, P; Scholz, N; Schopper, Herwig Franz; Schotanus, D J; Schwenke, J; Schwering, G; Sciacca, C; Sciarrino, D; Servoli, L; Shevchenko, S; Shivarov, N; Shoutko, V; Shukla, J; Shumilov, E; Shvorob, A V; Siedenburg, T; Son, D; Sopczak, André; Smith, B; Spillantini, P; Steuer, M; Stickland, D P; Stone, H; Stoyanov, B; Strässner, A; Strauch, K; Sudhakar, K; Sultanov, G G; Sun, L Z; Susinno, G F; Suter, H; Swain, J D; Tang, X W; Tauscher, Ludwig; Taylor, L; Ting, Samuel C C; Ting, S M; Tonutti, M; Tonwar, S C; Tóth, J; Tully, C; Tuchscherer, H; Tung, K L; Uchida, Y; Ulbricht, J; Uwer, U; Valente, E; Van de Walle, R T; Vesztergombi, G; Vetlitskii, I; Viertel, Gert M; Vivargent, M; Völkert, R; Vogel, H; Vogt, H; Vorobev, I; Vorobyov, A A; Vorvolakos, A; Wadhwa, M; Wallraff, W; Wang, J C; Wang, X L; Wang, Z M; Weber, A; Wittgenstein, F; Wu, S X; Wynhoff, S; Xu, J; Xu, Z Z; Yang, B Z; Yang, C G; Yao, X Y; Ye, J B; Yeh, S C; You, J M; Zalite, A; Zalite, Yu; Zemp, P; Zeng, Y; Zhang, Z; Zhang, Z P; Zhou, B; Zhu, G Y; Zhu, R Y; Zichichi, Antonino; Ziegler, F

    1997-01-01

    We report on the measurement of W-boson pair-production with the L3 detector at LEP at a centre-of-mass energy of 161.34~\\GeV. In a data sample corresponding to a total luminosity of 11~pb$^{-1}$, we select four-fermion events with high invariant masses of pairs of hadronic jets or leptons. Combining all final states, the measured total cross section for W-pair production is: $\\SWW = 2.89^{+0.81}_{-0.70}~(stat.)\\pm0.14~(syst.)$~pb. Within the Standard Model, this corresponds to a mass of the W boson of: $\\MW = 80.80^{+0.48}_{-0.42}~(exp.)\\pm 0.03$~(LEP)~\\GeV. Limits on anomalous triple-vector-boson couplings are derived. \\end{abstract}

  6. Installation and operation of the 400 kW 140 GHz gyrotron on the MTX experiment

    International Nuclear Information System (INIS)

    Ferguson, S.W.; Felker, B.; Jackson, M.C.; Petersen, D.E.; Sewall, N.R.; Stever, R.D.

    1991-09-01

    This paper describes the installation and operation of the 400 kW 140 GHz gyrotron used for plasma heating on the Microwave Tokamak Experiment (MTX) at Lawrence Livermore National Laboratory (LLNL). The Varian VGT-8140 gyrotron has operated at a power level of 400 kW for 100 ms in conjunction with MTX plasma shots. The gyrotron system is comprised of a high voltage (-80 kV) modulated power supply, a multistation CAMAC computer control, a 5-tesla superconducting magnet, a series of conventional copper magnets, a circulating fluorinert (FC75) window cooling system, a circulating oil cooling system, a water cooling system, and microwave frequency and power diagnostics. Additionally, a Vlasov launcher is used to convert the gyrotron TE 15,2 mode to a Gaussian beam. Two versions of the Vlasov launcher have been used on the gyrotron, one version designed by LLNL and one version designed by the Japan Atomic Energy Research Institute (JAERI). The Gaussian beam from the Vlasov launcher is transported to the MTX tokamak by a series of 5 mirrors in a 35-meter-long, high-efficiency, quasioptical beam transport system. A twist polarizer is built into one of the mirrors to adjust for horizontal polarization in the tokamak. No windows are used between the Vlasov reflector and the MTX tokamak. A laser alignment system is used to perform the initial system alignment. A summary of the design and operating characteristics of each of these systems is included. Also included is a summary of the system operation and performance

  7. POWER AND CULTURE IN THE SOUTH CHINA SEA

    Science.gov (United States)

    2016-02-16

    of Great Power Politics (New York: W.W. Norton , 2001), 19. 10 As quoted in Mearsheimer, The Tragedy of Great Power Politics, 19. 11 Mearsheimer...century’s defining battleground” by Robert Kaplan , land power is largely irrelevant. As Samuels pointed out, PRC moves in 1974 were the result of a new...University Press, 1995. Mearsheimer, John J. The Tragedy of Great Power Politics. New York: W. W. Norton , 2001. Poling, Gregory. Spratley

  8. Survey of the small (300 W to 300 kW) wind turbine market in Canada

    International Nuclear Information System (INIS)

    2005-01-01

    The significant growth in the Canadian wind power industry over the past decade has resulted in an increased number of large utility-scale wind farms appearing across Canada. Although large wind turbines are often acknowledged as a mature technology that can provide clean, reliable and economically competitive power, smaller wind turbines have had relatively little documentation in comparison. The aim of this report was to provide a profile of the Canadian market for small wind turbines (SWTs), divided into 3 categories: mini wind turbines with a rated power output from 300 watts to 1000 watts; small wind turbines up to 30 kW; and medium-sized wind turbines up to 300 kW. Study findings were based on interviews with industry experts and a comprehensive survey of 135 companies involved in the Canadian SWT industry. Details of annual sales and total installed capacity were provided, as well as a summary of key SWT markets. An overview of Canadian market demand and international SWT manufacturing capacity was presented. Opportunities and barriers were examined. It was observed that experiences in the United States have indicated that SWTs are more successful when combined with enabling policies, market incentives, and education and awareness raising. The U.S. small wind industry has estimated that in the near future, the SWT industry could supply 50,000 MW, employ 10,000 people and generate $1 billion per year. A number of opportunities for the promotion of the small wind industry in Canada were reviewed, including the niche manufacturing sector in the 20 kW to 50 kW range. Issues concerning the economic benefits of a SWT manufacturing industry were examined. It was suggested that as the SWT markets grow and mature, turbine prices are expected to fall and turbine effectiveness and reliability will increase. An SWT promotional strategy was outlined with incentives in 4 areas: (1) market development; (2) policy development; (3) technology development; and (4) education

  9. Electrodynamic wireless power transmission to a torsional receiver

    International Nuclear Information System (INIS)

    McEachern, K M; Arnold, D P

    2013-01-01

    This paper presents a wireless power transmission (WPT) concept that uses electrodynamic coupling and torsional motion of a permanent magnet in the receiver. The system is shown to transfer an average power of 3.09 mW (power density equal to 143 μW/cm 3 ) over a distance of 1 cm, an average power of 1.98 mW over a distance of 2 cm, and an average power of 126 μW over a distance of 7 cm. We also demonstrate unaltered power transmission through conductive media, including a human hand and an aluminum plate, highlighting a key advantage of the electrodynamic wireless power transmission approach

  10. Power program and nuclear power

    International Nuclear Information System (INIS)

    Chernilin, Yu.F.

    1990-01-01

    Main points of the USSR power program and the role of nuclear power in fuel and power complex of the country are considered. Data on dynamics of economic indices of electric power generation at nuclear power plants during 1980-1988 and forecasts till 2000 are presented. It is shown that real cost of 1 kW/h of electric power is equal to 1.3-1.8 cop., and total reduced cost is equal to 1.8-2.4 cop

  11. Thermal performance of various multilayer insulation systems below 80K

    International Nuclear Information System (INIS)

    Boroski, W.N.; Nicol, T.H.; Schoo, C.J.

    1992-04-01

    The SSC collider dipole cryostat consists of a vacuum shell operating at room temperature, two thermal shields operating near 80K and 20K respectively, and the superconducting magnet assembly operating near 4K. The cryostat design incorporates multilayer insulation (MLI) blankets to limit radiant heat transfer into the 80K and 20K thermal shields. Also, an MLI blanket is used to impede heat transfer through residual gas conduction into the 4K superconducting magnet assembly. A measurement facility at Fermilab has been used to experimentally optimize the thermal insulation system for the dipole cryostat. Previous thermal measurements have been used to define the 80K MLI system configuration and verify system performance. With the 80K MLI system defined, the current effort has focused on experimentally defining the optimum insulation scheme for the 20K thermal shield. The SSC design specification requires that radiant heat transfer be limited to 0.093 W/m 2 at an insulating vacuum of 10 -6 torr

  12. Calculation of the power distribution in the fuel rods of the low power research reactor using the MCNP4C code

    International Nuclear Information System (INIS)

    Dawahra, S.; Khattab, K.

    2011-01-01

    Highlights: → The MCNP4C code was used to calculate the power distribution in 3-D geometry in the MNSR reactor. → The maximum power of the individual rod was found in the fuel ring number 2 and was found to be 105 W. → The minimum power was found in the fuel ring number 9 and was 79.9 W. → The total power in the total fuel rods was 30.9 kW. - Abstract: The Monte Carlo method, using the MCNP4C code, was used in this paper to calculate the power distribution in 3-D geometry in the fuel rods of the Syrian Miniature Neutron Source Reactor (MNSR). To normalize the MCNP4C result to the steady state nominal thermal power, the appropriate scaling factor was defined to calculate the power distribution precisely. The maximum power of the individual rod was found in the fuel ring number 2 and was found to be 105 W. The minimum power was found in the fuel ring number 9 and was 79.9 W. The total power in the total fuel rods was 30.9 kW. This result agrees very well with nominal power reported in the reactor safety analysis report which equals 30 kW. Finally, the peak power factors, which are defined as the ratios between the maximum to the average and the maximum to the minimum powers were calculated to be 1.18 and 1.31 respectively.

  13. High power industrial picosecond laser from IR to UV

    Science.gov (United States)

    Saby, Julien; Sangla, Damien; Pierrot, Simonette; Deslandes, Pierre; Salin, François

    2013-02-01

    Many industrial applications such as glass cutting, ceramic micro-machining or photovoltaic processes require high average and high peak power Picosecond pulses. The main limitation for the expansion of the picosecond market is the cost of high power picosecond laser sources, which is due to the complexity of the architecture used for picosecond pulse amplification, and the difficulty to keep an excellent beam quality at high average power. Amplification with fibers is a good technology to achieve high power in picosecond regime but, because of its tight confinement over long distances, light undergoes dramatic non linearities while propagating in fibers. One way to avoid strong non linearities is to increase fiber's mode area. Nineteen missing holes fibers offering core diameter larger than 80μm have been used over the past few years [1-3] but it has been shown that mode instabilities occur at approximately 100W average output power in these fibers [4]. Recently a new fiber design has been introduced, in which HOMs are delocalized from the core to the clad, preventing from HOMs amplification [5]. In these so-called Large Pitch Fibers, threshold for mode instabilities is increased to 294W offering robust single-mode operation below this power level [6]. We have demonstrated a high power-high efficiency industrial picosecond source using single-mode Large Pitch rod-type fibers doped with Ytterbium. Large Pitch Rod type fibers can offer a unique combination of single-mode output with a very large mode area from 40 μm up to 100μm and very high gain. This enables to directly amplify a low power-low energy Mode Locked Fiber laser with a simple amplification architecture, achieving very high power together with singlemode output independent of power level or repetition rate.

  14. Measurement of the mass and the width of the W boson at LEP

    CERN Document Server

    Achard, P; Aguilar-Benítez, M; Alcaraz, J; Alemanni, G; Allaby, James V; Aloisio, A; Alviggi, M G; Anderhub, H; Andreev, V P; Anselmo, F; Arefev, A; Azemoon, T; Aziz, T; Bagnaia, P; Bajo, A; Baksay, G; Baksay, L; Baldew, S V; Banerjee, S; Banerjee, Sw; Barczyk, A; Barillère, R; Bartalini, P; Basile, M; Batalova, N; Battiston, R; Bay, A; Becattini, F; Becker, U; Behner, F; Bellucci, L; Berbeco, R; Berdugo, J; Berges, P; Bertucci, B; Betev, B L; Biasini, M; Biglietti, M; Biland, A; Blaising, J J; Blyth, S C; Bobbink, G J; Böhm, A; Boldizsar, L; Borgia, B; Bottai, S; Bourilkov, D; Bourquin, M; Braccini, S; Branson, J G; Brochu, F; Burger, J D; Burger, W J; Button, A J; Cai, X D; Capell, M; Cara Romeo, G; Carlino, G; Cartacci, A; Casaus, J; Cavallari, F; Cavallo, N; Cecchi, C; Cerrada, M; Chamizo-Llatas, M; Chang, Y H; Chemarin, M; Chen, A; Chen, G; Chen, G M; Chen, H F; Chen, H S; Chiefari, G; Cifarelli, L; Cindolo, F; Clare, I; Clare, R; Coignet, G; Colino, N; Costantini, S; de la Cruz, B; Cucciarelli, S; van Dalen, J A; De Asmundis, R; Deglon, P; Debreczeni, J; Degré, A; Dehmelt, K; Deiters, K; Della Volpe, D; Delmeire, E; Denes, P; De Notaristefani, F; De Salvo, A; Diemoz, M; Dierckxsens, M; Van Dierendonck, D N; Dionisi, C; Dittmar, M; Doria, A; Dova, M T; Duchesneau, D; Duda, M; Echenard, B; Eline, A; El-Hage, A; El-Mamouni, H; Engler, A; Eppling, F J; Extermann, P; Falagán, M A; Falciano, S; Favara, A; Fay, J; Fedin, O; Felcini, M; Ferguson, T; Fesefeldt, H S; Fiandrini, E; Field, J H; Filthaut, F; Fisher, P H; Fisher, W; Forconi, G; Freudenreich, Klaus; Furetta, C; Galaktionov, Yu; Ganguli, S N; García-Abia, P; Gataullin, M; Gentile, S; Giagu, S; Gong, Z F; Grenier, G; Grimm, O; Grünewald, M W; Guida, M; Gupta, V K; Gurtu, A; Gutay, L J; Haas, D; Hatzifotiadou, D; Hebbeker, T; Hervé, A; Hirschfelder, J; Hofer, H; Hohlmann, M; Holzner, G; Hou, S R; Jin, B N; Jindal, P; Jones, L W; de Jong, P; Josa-Mutuberria, I; Kaur, M; Kienzle-Focacci, M N; Kim, J K; Kirkby, Jasper; Kittel, E W; Klimentov, A; König, A C; Kopal, M; Koutsenko, V F; Kraber, M; Krämer, R W; Krüger, A; Kunin, A; Ladrón de Guevara, P; Laktineh, I; Landi, G; Lebeau, M; Lebedev, A; Lebrun, P; Lecomte, P; Lecoq, P; Le Coultre, P; Le Goff, J M; Leiste, R; Levtchenko, M; Levchenko, P M; Li, C; Likhoded, S; Lin, C H; Lin, W T; Linde, Frank L; Lista, L; Liu, Z A; Lohmann, W; Longo, E; Lü, Y S; Luci, C; Luminari, L; Lustermann, W; Ma, W G; Malgeri, L; Malinin, A; Maña, C; Mans, J; Martin, J P; Marzano, F; Mazumdar, K; McNeil, R R; Mele, S; Merola, L; Meschini, M; Metzger, W J; Mihul, A; Milcent, H; Mirabelli, G; Mnich, J; Mohanty, G B; Moulik, T; Muanza, G S; Muijs, A J M; Musy, M; Nagy, S; Nandakumar, R; Natale, S; Napolitano, M; Nessi-Tedaldi, F; Newman, H; Nisati, A; Novák, T; Nowak, H; Ofierzynski, R A; Organtini, G; Pal, I; Palomares, C; Paolucci, P; Paramatti, R; Passaleva, G; Patricelli, S; Paul, T; Pauluzzi, M; Paus, C; Pauss, F; Pedace, M; Pensotti, S; Perret-Gallix, D; Piccolo, D; Pierella, F; Pieri, M; Pioppi, M; Piroué, P A; Pistolesi, E; Plyaskin, V; Pohl, M; Pozhidaev, V; Pothier, J; Prokofev, D; Prokofiev, D O; Rahal-Callot, G; Rahaman, M A; Raics, P; Raja, N; Ramelli, R; Rancoita, P G; Ranieri, R; Raspereza, A V; Razis, P; Rembeczki, S; Ren, D; Rescigno, M; Reucroft, S; Riemann, S; Riles, K; Roe, B P; Romero, L; Rosca, A; Rosemann, C; Rosenbleck, C; Rosier-Lees, S; Roth, S; Rubio, J A; Ruggiero, G; Rykaczewski, H; Sakharov, A; Saremi, S; Sarkar, S; Salicio, J; Sánchez, E; Schäfer, C; Shchegelskii, V; Schopper, Herwig Franz; Schotanus, D J; Sciacca, C; Servoli, L; Shevchenko, S; Shivarov, N; Shoutko, V; Shumilov, E; Shvorob, A; Son, D; Souga, C; Spillantini, P; Steuer, M; Stickland, D P; Stoyanov, B; Strässner, A; Sudhakar, K; Sultanov, G G; Sun, L Z; Sushkov, S; Suter, H; Swain, J D; Swomi, W; Szillási, Z; Tang, X W; Tarjan, P; Tauscher, L; Taylor, L; Tellili, B; Teyssier, D; Timmermans, C; Ting, Samuel C C; Ting, S M; Tonwar, S C; Tóth, J; Tully, C; Tung, K L; Ulbricht, J; Valente, E; Van de Walle, R T; Vásquez, R; Vesztergombi, G; Vetlitskii, I; Viertel, G; Villa, S; Vivargent, M; Vlachos, S; Vodopyanov, I; Vogel, H; Vogt, H; Vorobev, I; Vorobyov, A A; Wadhwa, M; Wang, Q; Wang, X L; Wang, Z M; Weber, A; Weber, M; Wynhoff, S; Xia, L; Xu, Z Z; Yamamoto, J; Yang, B Z; Yang, C G; Yang, H J; Yang, M; Yeh, S C; Zalite, A; Zalite, Yu; Zhang, Z P; Zhao, J; Zhu, G Y; Zhu, R Y; Zhuang, H L; Zichichi, A; Zimmermann, B; Zöller, M

    2006-01-01

    The mass and the total decay width of the W boson are measured with the L3 detector at the LEP e+e- collider using W-boson pairs produced in 0.7/fb of data collected at centre-of-mass energies between 161 and 209GeV. Combining semi-leptonic and fully-hadronic final states, the mass and the width of the W boson are determined to be mW = 80.270 +/- 0.046 +/- 0.031 GeV and GW = 2.18 +/- 0.11 +/- 0.09 GeV, where the first uncertainty is statistical and the second systematic.

  15. A 66pW Discontinuous Switch-Capacitor Energy Harvester for Self-Sustaining Sensor Applications.

    Science.gov (United States)

    Wu, Xiao; Shi, Yao; Jeloka, Supreet; Yang, Kaiyuan; Lee, Inhee; Sylvester, Dennis; Blaauw, David

    2016-06-01

    We present a discontinuous harvesting approach for switch capacitor DC-DC converters that enables ultra-low power energy harvesting. By slowly accumulating charge on an input capacitor and then transferring it to a battery in burst-mode, switching and leakage losses in the DC-DC converter can be optimally traded-off with the loss due to non-ideal MPPT operation. The harvester uses a 15pW mode controller, an automatic conversion ratio modulator, and a moving sum charge pump for low startup energy upon a mode switch. In 180nm CMOS, the harvester achieves >40% end-to-end efficiency from 113pW to 1.5μW with 66pW minimum input power, marking a >10× improvement over prior ultra-low power harvesters.

  16. 183-W, M2 = 2.4 Yb:YAG Q -switched laser

    International Nuclear Information System (INIS)

    Honea, E.C.; Beach, R.J.; Mitchell, S.C.; Avizonis, P.V.

    1999-01-01

    We have fabricated a diode-array end-pumped Yb:YAG rod laser with output powers greater than 200thinspthinspW cw and 195thinspthinspW Q -switched at 5thinspthinspkHz. At an output power of 183thinspthinspW and a repetition rate of 5thinspthinspkHz, the beam quality was measured to be M 2 =2.4 . The laser design incorporates a hollow lens duct to concentrate the diode pump light for delivery to the end of the laser rod while maintaining access to the laser beam. This configuration provides increased flexibility for the resonator design and permits the use of birefringence compensation in the cavity to yield polarized output with increased efficiency. Using the recently described birefringence compensation method of Clarkson et al.thinspthinsp[in Conference on Lasers and Electro-Optics (Optical Society of America, Washington, D.C., 1998), paper CTuI3], we obtained 112thinspthinspW of cw power with a polarized beam of M 2 =3.2 . copyright 1999 Optical Society of America

  17. All-solid-state cw frequency-doubling Nd:YLiF4/LBO blue laser with 4.33 W output power at 454 nm under in-band diode pumping at 880 nm.

    Science.gov (United States)

    Lü, Yanfei; Zhang, Xihe; Cheng, Weibo; Xia, Jing

    2010-07-20

    We generated efficient blue laser output at 454 nm by intracavity frequency doubling of a continuous-wave (cw) diode-pumped Nd:YLiF(4) (Nd:YLF) laser at 908 nm based on the (4)F(3/2)-(4)I(9/2) transition. With 32.8 W of incident pump power at 880 nm and the frequency-doubling crystal LiB(3)O(5), a level as high as 4.33 W of cw output power at 454 nm is achieved, corresponding to an optical conversion efficiency of 13.2% with respect to the incident pump power. To the best of our knowledge, this is the first blue laser at 454 nm generated by intracavity frequency doubling of a diode-pumped Nd:YLF.

  18. 50 W Resonant SMPS with coreless transformer for AM radio application

    DEFF Research Database (Denmark)

    Nakhost, Pezhman; Munk-Nielsen, Stig

    2006-01-01

    Resonant converters are attractive in some applications, because of their soft-switching behaviour. The very low switching losses make them superior compared to traditional hard-switching converters. The present paper considers a 50 W resonant SMPS with coreless transformer for AM radio applicati......Resonant converters are attractive in some applications, because of their soft-switching behaviour. The very low switching losses make them superior compared to traditional hard-switching converters. The present paper considers a 50 W resonant SMPS with coreless transformer for AM radio...... percent deviation. The experimental tests show that the realized converter has a high performance and efficiency up to 87.6%. It is shown that with a DC input voltage range of 276-375 V, the output voltage is 15 V from 10 W to 50 W output power, except in no load. The output voltage ripple is 84 m......Vppand 114 mVppat 15 W and 50 W output power, respectively. In addition, ra switching frequency from 1.9 MHz up to around 4 MHz is possible....

  19. Small high cooling power space cooler

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, T. V.; Raab, J.; Durand, D.; Tward, E. [Northrop Grumman Aerospace Systems Redondo Beach, Ca, 90278 (United States)

    2014-01-29

    The small High Efficiency pulse tube Cooler (HEC) cooler, that has been produced and flown on a number of space infrared instruments, was originally designed to provide cooling of 10 W @ 95 K. It achieved its goal with >50% margin when limited by the 180 W output ac power of its flight electronics. It has also been produced in 2 stage configurations, typically for simultaneously cooling of focal planes to temperatures as low as 35 K and optics at higher temperatures. The need for even higher cooling power in such a low mass cryocooler is motivated by the advent of large focal plane arrays. With the current availability at NGAS of much larger power cryocooler flight electronics, reliable long term operation in space with much larger cooling powers is now possible with the flight proven 4 kg HEC mechanical cooler. Even though the single stage cooler design can be re-qualified for those larger input powers without design change, we redesigned both the linear and coaxial version passive pulse tube cold heads to re-optimize them for high power cooling at temperatures above 130 K while rejecting heat to 300 K. Small changes to the regenerator packing, the re-optimization of the tuned inertance and no change to the compressor resulted in the increased performance at 150 K. The cooler operating at 290 W input power achieves 35 W@ 150 K corresponding to a specific cooling power at 150 K of 8.25 W/W and a very high specific power of 72.5 W/Kg. At these powers the cooler still maintains large stroke, thermal and current margins. In this paper we will present the measured data and the changes to this flight proven cooler that were made to achieve this increased performance.

  20. Power Factor Improvement Using Automatic Power Factor Compensation (APFC) Device for Medical Industries in Malaysia

    OpenAIRE

    Zaidi Maryam Nabihah; Ali Adlan

    2018-01-01

    This paper present the project designed to correcting power factor for medical industries in Malaysia automatically. Which with hope to make the cost and energy usage efficient, because the energy source are depleting due to increase in population. Power factor is the ratio of real power and apparent power. This definition is mathematically represented as kW/kVA where kW is active power and kVA is apparent power (active + reactive). Reactive power is the non-working power generated by the mag...

  1. Efficient pump module coupling >1kW from a compact detachable fiber

    Science.gov (United States)

    Dogan, M.; Chin, R. H.; Fulghum, S.; Jacob, J. H.; Chin, A. K.

    2018-02-01

    In the most developed fiber amplifiers, optical pump power is introduced into the 400μm-diameter, 0.46NA first cladding of the double-clad, Yb-doped, gain fiber, using a (6+1):1 multi-mode fiber combiner. For this configuration, the core diameter and numerical aperture of the pump delivery fibers have maximum values of 225μm and 0.22, respectively. This paper presents the first fiber-coupled laser-diode pump module emitting more than 1kW of claddingmode- stripped power from a detachable 225μm, 0.22NA delivery fiber at 976nm. The electrical-to-optical power conversion efficiency at 1kW is 50%. The FWHM spectral width at 1kW output is 4nm and has an excellent overlap with the narrow absorption spectrum of ytterbium in glass. Six of these pump modules attached to a (6+1):1 multimode combiner enable a 5-6kW, single-mode, Yb-doped fiber amplifier.

  2. Laparoscopic Partial Nephrectomy With Potassium-titanyl-phosphate Laser Versus Conventional Laparoscopic Partial Nephrectomy: An Animal Randomized Controlled Trial

    NARCIS (Netherlands)

    Rioja, Jorge; Morcillo, Esther; Novalbos, José P.; Sánchez-Hurtado, Miguel A.; Soria, Federico; Pérez-Duarte, Francisco; Díaz-Güemes Martín-Portugüés, Idoia; Laguna, Maria Pilar; Sánchez-Margallo, Francisco Miguel; Rodríguez-Rubio Cortadellas, Federico

    2017-01-01

    OBJECTIVE To explore the feasibility, safety, and short-term results of potassium-titanyl-phosphate (KTP) laser laparoscopic partial nephrectomy (KTP-LPN) vs conventional laparoscopic partial nephrectomy (C-LPN). MATERIALS AND METHODS Thirty large white female pigs were randomized to KTP-LPN or

  3. 1.5  kW efficient CW Nd:YAG planar waveguide MOPA laser.

    Science.gov (United States)

    Wang, Juntao; Wu, Zhenhai; Su, Hua; Zhou, Tangjian; Lei, Jun; Lv, Wenqiang; He, Jing; Xu, Liu; Chen, Yuejian; Wang, Dan; Tong, Lixin; Hu, Hao; Gao, Qingsong; Tang, Chun

    2017-08-15

    In this Letter, we report a 1064 nm continuous wave Nd:YAG planar waveguide laser with an output power of 1544 W based on the structure of the master oscillator power amplification. A fiber laser is used as the master oscillator, and diode laser arrays are used as the pump source of the waveguide laser amplifier. The dimension of the waveguide is 1  mm (T)×10  mm (W)×60  mm (L), and the dual end oblique pumping is adopted with different angles. After a single-pass amplification, the power is scaled from 323 to 1544 W with the pump power of 2480 W, leading to an optical-to-optical efficiency of 49%. At the maximum output, the beam quality M 2 are measured to be 2.8 and 7.0 in the guided direction and the unguided direction, respectively. To the best of our knowledge, this is the highest output power of a Nd:YAG planar waveguide laser to date.

  4. Development of a low cost integrated 15 kW A.C. solar tracking sub-array for grid connected PV power system applications

    Science.gov (United States)

    Stern, M.; West, R.; Fourer, G.; Whalen, W.; Van Loo, M.; Duran, G.

    1997-02-01

    Utility Power Group has achieved a significant reduction in the installed cost of grid-connected PV systems. The two part technical approach focused on 1) The utilization of a large area factory assembled PV panel, and 2) The integration and packaging of all sub-array power conversion and control functions within a single factory produced enclosure. Eight engineering prototype 15kW ac single axis solar tracking sub-arrays were designed, fabricated, and installed at the Sacramento Municipal Utility District's Hedge Substation site in 1996 and are being evaluated for performance and reliability. A number of design enhancements will be implemented in 1997 and demonstrated by the field deployment and operation of over twenty advanced sub-array PV power systems.

  5. 300 mW of coherent light at 488 nm using a generic approach

    DEFF Research Database (Denmark)

    Karamehmedovic, Emir; Pedersen, Christian; Andersen, Martin Thalbitzer

    2008-01-01

    We present a generic approach for efficient generation of CW light with a predetermined wavelength within the visible or UV spectrum. Based on sum-frequency generation (SFG), the circulating intra-cavity field of a high-finesse diode pumped CW solid-state laser (DPSSL) and the output from a tapered...... of ECDLs, the high intra-cavity field of DPSSLs and flexible quasi phase matching in pp-KTP. We demonstrate the potential of the proposed method by synthesizing a beam at 488 run using a single-frequency tapered ECDL with a center wavelength of 766 run in combination with a high finesse Nd:YVO4 laser...... any desired wavelength within the visible spectrum....

  6. Application of REVEAL-W to risk-based configuration control

    International Nuclear Information System (INIS)

    Dezfuli, H.; Meyer, J.; Modarres, M.

    1994-01-01

    Over the past two years, the concept of risk-based configuration control has been introduced to the US Nuclear Regulatory Commission and the nuclear industry. Converting much of the current, deterministically based regulation of nuclear power plants to risk-based regulation can result in lower levels of risk while relieving unnecessary burdens on power plant operators and regulatory staff. To achieve the potential benefits of risk-based configuration control, the risk models developed for nuclear power plants should be (1) flexible enough to effectively support necessary risk calculations, and (2) transparent enough to encourage their use by all parties. To address these needs, SCIENTECH, Inc., has developed the PC-based REVEAL W (formerly known as SMART). This graphic-oriented and user-friendly application software allows the user to develop transparent complex logic models based on the concept of the master plant logic diagram. The logic model is success-oriented and compact. The analytical capability built into REVEAL W is generic, so the software can support different types of risk-based evaluations, such as probabilistic safety assessment, accident sequence precursor analysis, design evaluation and configuration management. In this paper, we focus on the application of REVEAL W to support risk-based configuration control of nuclear power plants. (author)

  7. Przygotowanie materiałów do e-learningu w Bibliotece Głównej Uniwersytetu Pedagogicznego w Krakowie

    Directory of Open Access Journals (Sweden)

    Folga Agnieszka

    2012-06-01

    Full Text Available The article presents the preparation of teaching materials for a library lesson to be used in the implementation of blended learning in the Main Library of the Pedagogical University in Kraków. Blended learning is a combination of traditional forms of training with e-learning. The content of the prepared PowerPoint presentation is discussed, as well as the text related to searching and ordering books from the electronic catalogue, and the test questions for students who begin their education at the University.

  8. Power loss measurement of implantable wireless power transfer components using a Peltier device balance calorimeter

    International Nuclear Information System (INIS)

    Leung, Ho Yan; Budgett, David M; Taberner, Andrew; Hu, Patrick

    2014-01-01

    Determining heat losses in power transfer components operating at high frequencies for implantable inductive power transfer systems is important for assessing whether the heat dissipated by the component is acceptable for implantation and medical use. However, this is a challenge at high frequencies and voltages due to limitations in electronic instrumentation. Calorimetric methods of power measurement are immune to the effects of high frequencies and voltages; hence, the measurement is independent of the electrical characteristics of the system. Calorimeters have been widely used to measure the losses of high power electrical components (>50 W), however it is more difficult to perform on low power components. This paper presents a novel power measurement method for components dissipating anywhere between 0.2 W and 1 W of power based on a heat balance calorimeter that uses a Peltier device as a balance sensor. The proposed balance calorimeter has a single test accuracy of ±0.042 W. The experimental results revealed that there was up to 35% difference between the power measurements obtained with electrical methods and the proposed calorimeter. (paper)

  9. Photovoltaic Power Applications in France. National Survey Report 2011

    International Nuclear Information System (INIS)

    Durand, Yvonnick

    2012-01-01

    the feed-in tariffs financed by customers of electricity companies through their CSPE contribution is estimated at 800 MEUR for 2011. The cost of tax credit is evaluated at 670 MEUR (2010). Main R and D programs are funded by public agencies ADEME, ANR and OSEO. Under the auspices of the Ministry of Ecology and within the National future investment program (PIA), ADEME was given responsibility for launching a call for expressions of interest in solar RD and D (AMI PV and AMI solaire). Eight projects were selected within the AMI PV initiative. The ANR launched the three-year PROGELEC research program (renewable electricity production and management) in early 2011. The 'Photovoltaic electricity production' theme selected five research projects. The new 3 to 5-year R and D projects will receive support from ADEME and ANR (refundable advances and subsidies) amounting to around 80 MEUR. The turnkey price of building integrated rooftop systems was around 3,9 EUR/W by end of 2011 compared with 5,9 EUR/W 12 months ago (source SER), a 35 % decrease. Large roof of commercial/industrial buildings between 250 kW and 500 kW were 53 % less expensive at 2,6 EUR/W and turnkey prices of ground-mounted centralised systems were around 2,0 EUR/W (56 % decrease during the year). Reduction is principally due to price reduction of modules and, to a lesser extent, other components such as inverters. During 2011, the drop in the price of photovoltaic modules and systems induced a significant increase in the internal profitability rate of the projects and led to a rapid expansion in medium- and high-power systems. There are about 210 players active in the photovoltaic field (not including installers). In 2011, the multi-crystalline silicon ingot production capacity was 1 360 tons, crystalline silicon cell production capacity was around 100 MW and photovoltaic module production capacity was estimated at 470 MW. During 2011, some projects to develop new production facilities or to

  10. A NEW MEASUREMENT OF THE W BOSON MASS FROM CDF

    CERN Multimedia

    Ashutosh Kotwal

    CDF has measured the W boson mass using approx. 200pb-1 of data collected at  s = 1.96 TeV. The preliminary result mW = 80.413 ± 0.034(stat) ± 0.034(syst) GeV supports and strengthens the hypothesis of a light Higgs boson, based on the global electroweak fit in the standard model framework. The total measurement uncertainty of 48 MeV makes this result the most precise single measurement of the W boson mass to date. The mass of the W boson is a very interesting quantity. Experimentally, it can be measured precisely because of the two-body decay of the W boson into a charged lepton and a neutrino. Theoretically, it receives self-energy corrections due to vacuum fluctuations involving virtual particles. Thus the W boson mass probes the particle spectrum in nature, including those particles that have yet to be observed directly. The hypothetical particle of most immediate interest is the Higgs boson, representing the quantum of the Higgs field that spontaneously acquires a vacuu...

  11. Photoselective vaporization of the prostate in men with a history of chronic oral anti-coagulation

    Directory of Open Access Journals (Sweden)

    Omer F. Karatas

    2010-04-01

    Full Text Available PURPOSE: A considerable percentage of patients with benign prostatic hyperplasia (BPH also have additional cardiac pathologies, which often require anticoagulant therapy. The aim of this study was to evaluate the efficacy and safety of photoselective vaporization of the prostate (PVP for BPH in cardiac patients receiving anticoagulant therapy. MATERIALS AND METHODS: A total of 67 patients suffering from BPH and high risk cardiac pathologies were operated on using laser prostatectomy. All patients had cardiac pathologies with bleeding disorders requiring anticoagulant use, and underwent standard urologic evaluation for BPH. Patients were treated with laser prostatectomy for relief of the obstruction using the KTP/532 laser energy at 80 W. RESULTS: The mean patient age was 71.4 years (range 55-80. Mean prostate volume on transrectal ultrasonography was 73.2 mL (range 44-120. Operation time ranged from 40 to 90 min, with an average value of 55 min. The average hospital stay was 48 hours (range 12-72 and the Foley catheters were removed within 48 hours, with a mean catheterization time of 34.2 ± 5.9 hours (0-48. No patient required an additional procedure due to severe bleeding necessitating intervention during the early postoperative phase. Mean International symptoms scoring system (IPSS values and post voiding residual volume decreased and peak urinary flow rate increased (p < 0.001. Our results showed that the mean prostate volume had decreased by 53% at 6 months. CONCLUSIONS: High-power photo selective laser vaporization prostatectomy is a feasible, safe, and effective alternative for the minimal invasive management of BPH, particularly in cardiac patients receiving anticoagulant therapy.

  12. A Guidebook on Grid Interconnection and Islanded Operation of Mini-Grid Power Systems Up to 200 kW

    Energy Technology Data Exchange (ETDEWEB)

    Greacen, Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Engel, Richard [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Quetchenbach, Thomas [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-04-01

    A Guidebook on Grid Interconnection and Islanded Operation of Mini-Grid Power Systems Up to 200 kW is intended to help meet the widespread need for guidance, standards, and procedures for interconnecting mini-grids with the central electric grid as rural electrification advances in developing countries, bringing these once separate power systems together. The guidebook aims to help owners and operators of renewable energy mini-grids understand the technical options available, safety and reliability issues, and engineering and administrative costs of different choices for grid interconnection. The guidebook is intentionally brief but includes a number of appendices that point the reader to additional resources for indepth information. Not included in the scope of the guidebook are policy concerns about “who pays for what,” how tariffs should be set, or other financial issues that are also paramount when “the little grid connects to the big grid.”

  13. A 9.61-W, b-cut Tm,Ho:YAP laser in Q-switched mode operation

    Science.gov (United States)

    Li, Guoxing; Yang, Xining; Zhang, Ziqiu; Zhang, Hongda; Zhang, Liang

    2018-02-01

    A high energy of b-cut Tm, Ho:YAlO3 laser is reported in the paper. The laser operated in acousto-optical Qswitched mode at 2.12 μm. The output average power of 9.61 W was achieved at the pulse repetition frequency of 10 kHz ,and the power of 11.6 W was acquired in continuous wave mode. Moreover, the energy per pulse of 0.961 mJ in 64.4 ns was acquired at 10 kHz with a 14.92-kW peak power.

  14. Lightweight Battery Charge Regulator Used to Track Solar Array Peak Power

    Science.gov (United States)

    Soeder, James F.; Button, Robert M.

    1999-01-01

    A battery charge regulator based on the series-connected boost regulator (SCBR) technology has been developed for high-voltage spacecraft applications. The SCBR regulates the solar array power during insolation to prevent battery overcharge or undercharge conditions. It can also be used to provide regulated battery output voltage to spacecraft loads if necessary. This technology uses industry-standard dc-dc converters and a unique interconnection to provide size, weight, efficiency, fault tolerance, and modularity benefits over existing systems. The high-voltage SCBR shown in the photograph has demonstrated power densities of over 1000 watts per kilogram (W/kg). Using four 150-W dc-dc converter modules, it can process 2500 W of power at 120 Vdc with a minimum input voltage of 90 Vdc. Efficiency of the SCBR was 94 to 98 percent over the entire operational range. Internally, the unit is made of two separate SCBR s, each with its own analog control circuitry, to demonstrate the modularity of the technology. The analog controllers regulate the output current and incorporate the output voltage limit with active current sharing between the two units. They also include voltage and current telemetry, on/off control, and baseplate temperature sensors. For peak power tracking, the SCBR was connected to a LabView-based data acquisition system for telemetry and control. A digital control algorithm for tracking the peak power point of a solar array was developed using the principle of matching the source impedance with the load impedance for maximum energy transfer. The algorithm was successfully demonstrated in a simulated spacecraft electrical system at the Boeing PhantomWorks High Voltage Test Facility in Seattle, Washington. The system consists of a 42-string, high-voltage solar array simulator, a 77-cell, 80-ampere-hour (A-hr) nickel-hydrogen battery, and a constant power-load module. The SCBR and the LabView control algorithm successfully tracked the solar array peak

  15. Measurement of the Mass and Width of the W Boson in $e^+ e^-$ Collisions at $\\sqrt{s}$ = 189 GeV

    CERN Document Server

    Abreu, P.; Adye, T.; Adzic, P.; Albrecht, Z.; Alderweireld, T.; Alekseev, G.D.; Alemany, R.; Allmendinger, T.; Allport, P.P.; Almehed, S.; Amaldi, U.; Amapane, N.; Amato, S.; Anashkin, E.; Anassontzis, E.G.; Andersson, P.; Andreazza, A.; Andringa, S.; Anjos, N.; Antilogus, P.; Apel, W.D.; Arnoud, Y.; Asman, B.; Augustin, J.E.; Augustinus, A.; Baillon, P.; Ballestrero, A.; Bambade, P.; Barao, F.; Barbiellini, G.; Barbier, R.; Bardin, Dmitri Yu.; Barker, G.J.; Baroncelli, A.; Battaglia, M.; Baubillier, M.; Becks, K.H.; Begalli, M.; Behrmann, A.; Bellunato, T.F.; Belokopytov, Yu.; Belous, K.; Benekos, N.C.; Benvenuti, A.C.; Berat, C.; Berggren, M.; Berntzon, L.; Bertrand, D.; Besancon, M.; Besson, N.; Bilenky, Mikhail S.; Bloch, D.; Blom, H.M.; Bol, L.; Bonesini, M.; Boonekamp, M.; Booth, P.S.L.; Borisov, G.; Bosio, C.; Botner, O.; Boudinov, E.; Bouquet, B.; Bowcock, T.J.V.; Boyko, I.; Bozovic, I.; Bracko, M.; Branchini, P.; Brenner, R.A.; Bruckman, P.; Brunet, J.M.; Bugge, L.; Buschmann, P.; Caccia, M.; Calvi, M.; Camporesi, T.; Canale, V.; Carena, F.; Carroll, L.; Caso, C.; Castillo Gimenez, M.V.; Cattai, A.; Cavallo, F.R.; Chapkin, M.; Charpentier, P.; Checchia, P.; Chelkov, G.A.; Chierici, R.; Chliapnikov, P.; Chochula, P.; Chorowicz, V.; Chudoba, J.; Cieslik, K.; Collins, P.; Contri, R.; Cortina, E.; Cosme, G.; Cossutti, F.; Costa, M.; Crawley, H.B.; Crennell, D.; Croix, J.; Crosetti, G.; Cuevas Maestro, J.; Czellar, S.; D'Hondt, J.; Dalmau, J.; Davenport, M.; Da Silva, W.; Della Ricca, G.; Delpierre, P.; Demaria, N.; De Angelis, A.; De Boer, W.; De Clercq, C.; De Lotto, B.; De Min, A.; De Paula, L.; Dijkstra, H.; Di Ciaccio, L.; Doroba, K.; Dracos, M.; Drees, J.; Dris, M.; Eigen, G.; Ekelof, T.; Ellert, M.; Elsing, M.; Engel, J.P.; Espirito Santo, M.C.; Fanourakis, G.; Fassouliotis, D.; Feindt, M.; Fernandez, J.; Ferrer, A.; Ferrer-Ribas, E.; Ferro, F.; Firestone, A.; Flagmeyer, U.; Foeth, H.; Fokitis, E.; Fontanelli, F.; Franek, B.; Frodesen, A.G.; Fruhwirth, R.; Fulda-Quenzer, F.; Fuster, J.; Galloni, A.; Gamba, D.; Gamblin, S.; Gandelman, M.; Garcia, C.; Gaspar, C.; Gaspar, M.; Gasparini, U.; Gavillet, P.; Gazis, Evangelos; Gele, D.; Geralis, T.; Ghodbane, N.; Gil Botella, Ines; Glege, F.; Gokieli, R.; Golob, B.; Gomez-Ceballos, G.; Goncalves, P.; Gonzalez Caballero, I.; Gopal, G.; Gorn, L.; Gouz, Yu.; Gracco, V.; Grahl, J.; Graziani, E.; Grosdidier, G.; Grzelak, K.; Guy, J.; Haag, C.; Hahn, F.; Hahn, S.; Haider, S.; Hallgren, A.; Hamacher, K.; Hansen, J.; Harris, F.J.; Haug, S.; Hauler, F.; Hedberg, V.; Heising, S.; Hernandez, J.J.; Herquet, P.; Herr, H.; Hertz, O.; Higon, E.; Holmgren, S.O.; Holt, P.J.; Hoorelbeke, S.; Houlden, M.; Hrubec, J.; Hughes, G.J.; Hultqvist, K.; Jackson, John Neil; Jacobsson, R.; Jalocha, P.; Jarlskog, C.; Jarlskog, G.; Jarry, P.; Jean-Marie, B.; Jeans, D.; Johansson, Erik Karl; Jonsson, P.; Joram, C.; Juillot, P.; Jungermann, L.; Kapusta, Frederic; Karafasoulis, K.; Katsanevas, S.; Katsoufis, E.C.; Keranen, R.; Kernel, G.; Kersevan, B.P.; Khokhlov, Yu.A.; Khomenko, B.A.; Khovanski, N.N.; Kiiskinen, A.; King, B.; Kinvig, A.; Kjaer, N.J.; Klapp, O.; Kluit, P.; Kokkinias, P.; Kostioukhine, V.; Kourkoumelis, C.; Kouznetsov, O.; Krammer, M.; Kriznic, E.; Krumstein, Z.; Kubinec, P.; Kucharczyk, M.; Kurowska, J.; Lamsa, J.W.; Laugier, J.P.; Leder, G.; Ledroit, Fabienne; Leinonen, L.; Leisos, A.; Leitner, R.; Lenzen, G.; Lepeltier, V.; Lesiak, T.; Lethuillier, M.; Libby, J.; Liebig, W.; Liko, D.; Lipniacka, A.; Lippi, I.; Loken, J.G.; Lopes, J.H.; Lopez, J.M.; Lopez-Fernandez, R.; Loukas, D.; Lutz, P.; Lyons, L.; MacNaughton, J.; Mahon, J.R.; Maio, A.; Malek, A.; Maltezos, S.; Malychev, V.; Mandl, F.; Marco, J.; Marco, R.; Marechal, B.; Margoni, M.; Marin, J.C.; Mariotti, C.; Markou, A.; Martinez-Rivero, C.; Marti i Garcia, S.; Masik, J.; Mastroyiannopoulos, N.; Matorras, F.; Matteuzzi, C.; Matthiae, G.; Mazzucato, F.; Mazzucato, M.; McCubbin, M.; McKay, R.; McNulty, R.; McPherson, G.; Merle, E.; Meroni, C.; Meyer, W.T.; Migliore, E.; Mirabito, L.; Mitaroff, W.A.; Mjoernmark, U.; Moa, T.; Moch, M.; Monig, Klaus; Monge, M.R.; Montenegro, J.; Moraes, D.; Morettini, P.; Morton, G.; Mueller, U.; Muenich, K.; Mulders, M.; Mundim, L.M.; Murray, W.J.; Muryn, B.; Myatt, G.; Myklebust, T.; Nassiakou, M.; Navarria, F.L.; Nawrocki, K.; Negri, P.; Nemecek, S.; Neufeld, N.; Nicolaidou, R.; Niezurawski, P.; Nikolenko, M.; Nomokonov, V.; Nygren, A.; Obraztsov, V.; Olshevski, A.G.; Onofre, A.; Orava, R.; Osterberg, K.; Ouraou, A.; Oyanguren, A.; Paganoni, M.; Paiano, S.; Pain, R.; Paiva, R.; Palacios, J.; Palka, H.; Papadopoulou, T.D.; Pape, L.; Parkes, C.; Parodi, F.; Parzefall, U.; Passeri, A.; Passon, O.; Peralta, L.; Perepelitsa, V.; Pernicka, M.; Perrotta, A.; Petridou, C.; Petrolini, A.; Phillips, H.T.; Pierre, F.; Pimenta, M.; Piotto, E.; Podobnik, T.; Poireau, V.; Pol, M.E.; Polok, G.; Poropat, P.; Pozdniakov, V.; Privitera, P.; Pukhaeva, N.; Pullia, A.; Radojicic, D.; Ragazzi, S.; Rahmani, H.; Read, Alexander L.; Rebecchi, P.; Redaelli, Nicola Giuseppe; Regler, M.; Rehn, J.; Reid, D.; Reinhardt, R.; Renton, P.B.; Resvanis, L.K.; Richard, F.; Ridky, J.; Rinaudo, G.; Ripp-Baudot, Isabelle; Romero, A.; Ronchese, P.; Rosenberg, E.I.; Rosinsky, P.; Roudeau, P.; Rovelli, T.; Ruhlmann-Kleider, V.; Ruiz, A.; Saarikko, H.; Sacquin, Y.; Sadovsky, A.; Sajot, G.; Salmi, L.; Salt, J.; Sampsonidis, D.; Sannino, M.; Savoy-Navarro, A.; Schwanda, C.; Schwemling, P.; Schwering, B.; Schwickerath, U.; Scuri, Fabrizio; Sedykh, Y.; Segar, A.M.; Sekulin, R.; Sette, G.; Shellard, R.C.; Siebel, M.; Simard, L.; Simonetto, F.; Sisakian, A.N.; Smadja, G.; Smirnov, N.; Smirnova, O.; Smith, G.R.; Sokolov, A.; Solovianov, O.; Sopczak, A.; Sosnowski, R.; Spassov, T.; Spiriti, E.; Squarcia, S.; Stanescu, C.; Stanitzki, M.; Stevenson, K.; Stocchi, A.; Strauss, J.; Strub, R.; Stugu, B.; Szczekowski, M.; Szeptycka, M.; Tabarelli, T.; Taffard, A.; Tegenfeldt, F.; Terranova, F.; Timmermans, Jan; Tinti, N.; Tkatchev, L.G.; Tobin, M.; Todorova, S.; Tome, B.; Tonazzo, A.; Tortora, L.; Tortosa, P.; Treille, D.; Tristram, G.; Trochimczuk, M.; Troncon, C.; Turluer, M.L.; Tyapkin, I.A.; Tyapkin, P.; Tzamarias, S.; Ullaland, O.; Uvarov, V.; Valenti, G.; Vallazza, E.; Vander Velde, C.; Van Dam, Piet; Van den Boeck, W.; Van Doninck, Walter; Van Eldik, J.; Van Lysebetten, A.; van Remortel, N.; Van Vulpen, I.; Vegni, G.; Ventura, L.; Venus, W.; Verbeure, F.; Verdier, P.; Verlato, M.; Vertogradov, L.S.; Verzi, V.; Vilanova, D.; Vitale, L.; Vlasov, E.; Vodopianov, A.S.; Voulgaris, G.; Vrba, V.; Wahlen, H.; Washbrook, A.J.; Weiser, C.; Wicke, D.; Wickens, J.H.; Wilkinson, G.R.; Winter, M.; Witek, M.; Wolf, G.; Yi, J.; Yushchenko, O.; Zalewska, A.; Zalewski, P.; Zavrtanik, D.; Zevgolatakos, E.; Zimine, N.I.; Zintchenko, A.; Zoller, P.; Zumerle, G.; Zupan, M.

    2001-01-01

    A measurement of the W mass and width has been performed by the DELPHI collaboration using the data collected during 1998. The data sample has an integrated luminosity of 155 pb^{-1} and an average centre-of-mass energy of 188.6 GeV. Results are obtained by applying the method of direct reconstruction of the mass of the W from its decay products in both the W+W- -> lvqq and W+W- -> qqqq channels. The W mass result for the 1998 data set is M_W = 80.387 +/- 0.087 (stat) +/- 0.034 (syst) +/- 0.017 (LEP) +/- 0.035 (FSI) GeV/c2, where FSI represents the uncertainty due to final state interaction effects in the qqqq channel, and LEP represents that arising from the knowledge of the beam energy of the accelerator. Combining this result with those previously published by the DELPHI collaboration gives the result M_W = 80.359 +/- 0.074 (stat) +/- 0.032 (syst) +/- 0.017 (LEP) +/- 0.033 (FSI) GeV/c2. The combined value for the W width is \\Gamma_W = 2.266 +/- 0.176 (stat) +/- 0.056 (syst) +/- 0.052 (FSI) GeV/c2.

  16. Effect of turbine materials on power generation efficiency from free water vortex hydro power plant

    International Nuclear Information System (INIS)

    Sritram, P; Treedet, W; Suntivarakorn, R

    2015-01-01

    The objective of this research was to study the effect of turbine materials on power generation efficiency from the water free vortex hydro power plant made of steel and aluminium. These turbines consisted of five blades and were twisted with angles along the height of water. These blades were the maximum width of 45 cm. and height of 32 cm. These turbines were made and experimented for the water free vortex hydro power plant in the laboratory with the water flow rate of 0.68, 1.33, 1.61, 2.31, 2.96 and 3.63 m 3 /min and an electrical load of 20, 40, 60, 80 and 100 W respectively. The experimental results were calculated to find out the torque, electric power, and electricity production efficiency. From the experiment, the results showed that the maximum power generation efficiency of steel and aluminium turbine were 33.56% and 34.79% respectively. From the result at the maximum water flow rate of 3.63 m 3 /min, it was found that the torque value and electricity production efficiency of aluminium turbine was higher than that of steel turbine at the average of 8.4% and 8.14%, respectively. This result showed that light weight of water turbine can increase the torque and power generation efficiency. (paper)

  17. Miejsce muzeów w turystyce kulturowej w Polsce

    OpenAIRE

    Krakowiak, Beata

    2013-01-01

    The article presents the museums, their potential and their significance for cultural tourism in Poland. Its aims are achieved through a presentation of registered national museums, ‘monuments of history’, museum buildings and the cultural activities undertaken by these institutions Artykuł dotyczy potencjału muzealnego oraz jego znaczenia dla turystyki kulturowej w Polsce. Zamierzone cele pracy realizowane są poprzez prezentację muzeów rejestrowanych, narodowych, muzeów-pomników histor...

  18. Measurements of the $W$ Boson Mass with the D0 Detector

    Energy Technology Data Exchange (ETDEWEB)

    Lopes de Sa, Rafael [Stony Brook Univ., NY (United States)

    2013-01-01

    In the first part, we describe what is the W boson mass in the context of the Standard Model. We discuss the prominent role this physical observable plays in the determination of the internal self consistency of the Electroweak Sector. We review measurements and calculation of the W boson mass done in past and argue about the importance and feasibility of improving the experimental determination. We give a description of the Fermilab Tevatron Collider and the D0 detector, highlighting the relevant parts for the measurement described in this Dissertation. In the second part, we give a detailed description of a measurement of the W boson mass using the D0 Central Calorimeter. The measurement uses 1.68 x 106 candidates from W → en decays, corresponding to 4.3 fb-1 of integrated luminosity collected from 2006 to 2009. We measure the mass using the transverse mass, electron transverse momentum, and missing transverse energy distributions. The transverse mass and electron transverse momentum measurements are the most precise and are combined to give MW = 80.367 ± 0.013(stat) ± 0.023 (syst) GeV = 80.367 ± 0.026 GeV. This is combined with an earlier D0 result determined using an independent 1 fb-1 data sample, also with central electrons only, to give MW = 80.375± 0.023 GeV. The uncertainty in the measurement is dominated by the determination of the calorimeter electron energy scale, the W sample size, the knowledge of the parton distribution function. In the third part, we discuss methods of reducing the dominant uncertainties in the W boson mass measurements. We show that introducing electrons detected in the End Calorimeters greatly reduce the measurement systematic uncertainty, especially the on related to the parton distribution functions. We describe a precise calibration of the End Calorimeter using Z → ee events corresponding to 4.3 fb-1 of integrated luminosity. The calibration is an important

  19. Powerful infrared emitting diodes

    Directory of Open Access Journals (Sweden)

    Kogan L. M.

    2012-02-01

    Full Text Available Powerful infrared LEDs with emission wavelength 805 ± 10, 870 ± 20 and 940 ± 10 nm developed at SPC OED "OPTEL" are presented in the article. The radiant intensity of beam diode is under 4 W/sr in the continuous mode and under 100 W/sr in the pulse mode. The radiation power of wide-angle LEDs reaches 1 W in continuous mode. The external quantum efficiency of emission IR diodes runs up to 30%. There also has been created infrared diode modules with a block of flat Fresnel lenses with radiant intensity under 70 W/sr.

  20. System 80+{trademark} standard design incorporates radiation protection lessons learned

    Energy Technology Data Exchange (ETDEWEB)

    Crom, T.D.; Naugle, C.L. [Duke Engineering & Services, Inc., Charlotte, NC (United States); Turk, R.S. [ABB Combustion Engineering Nuclear Power, Windsor, CT (United States)

    1995-03-01

    Many lessons have been learned from the current generation of nuclear plants in the area of radiation protection. The following paper will outline how the lessons learned have been incorporated into the design and operational philosophy of the System 80+{trademark} Standard Design currently under development by ABB Combustion Engineering (ABB-CE) with support from Duke Engineering and Services, Inc. and Stone and Webster Engineering Corporation in the Balance-of-Plant design. The System 80+{trademark} Standard Design is a complete nuclear power plant for national and international markets, designed in direct response to utility needs for the 1990`s, and scheduled for Nuclear Regulatory Commission (NRC) Design Certification under the new standardization rule (10 CFR Part 52). System 80+{trademark} is a natural extension of System 80{sup R} technology, an evolutionary change based on proven Nuclear Steam Supply System (NSSS) in operation at Palo Verde in Arizona and under construction at Yonggwang in the Republic of Korea. The System 80+{trademark} Containment and much of the Balance of Plant design is based upon Duke Power Company`s Cherokee Plant, which was partially constructed in the late 1970`s, but, was later canceled (due to rapid declined in electrical load growth). The System 80+{trademark} Standard Design meets the requirements given in the Electric Power Research Institute (EPRI) Advanced Light Water Reactor (ALWR) Requirements Document. One of these requirements is to limit the occupational exposure to 100 person-rem/yr. This paper illustrates how this goal can be achieved through the incorporation of lessons learned, innovative design, and the implementation of a common sense approach to operation and maintenances practices.

  1. Development of a direct methanol fuel cell system for the power segment below 5 kW; Entwicklung eines Direkt-Methanol-Brennstoffzellensystems der Leistungsklasse kleiner 5 kW

    Energy Technology Data Exchange (ETDEWEB)

    Noelke, M.

    2006-10-20

    of the operational parameter on characteristic performance indicators like electrical power, efficiency, and power density is analysed in combination with the heat and water management of the system. The system can be optimized only for single specific targets. For example the best system efficiency has been evaluated for a cell voltage of 400 mV and a stack temperature of 70 C. In the final part the development of the power supply of a Scooter is described. A compact system with a net power output of 1230 W has been realized. The system efficiency amounts up to 18.8 %. (orig.)

  2. Development of a Low Cost 10kW Tubular SOFC Power System

    Energy Technology Data Exchange (ETDEWEB)

    Bessette, Norman [Acumentrics Corporation, Westwood, MA (United States); Litka, Anthony [Acumentrics Corporation, Westwood, MA (United States); Rawson, Jolyon [Acumentrics Corporation, Westwood, MA (United States); Schmidt, Douglas [Acumentrics Corporation, Westwood, MA (United States)

    2013-06-06

    The DOE program funded from 2003 through early 2013 has brought the Acumentrics SOFC program from an early stage R&D program to an entry level commercial product offering. The development work started as one of the main core teams under the DOE Solid State Energy Conversion Alliance (SECA) program administered by the National Energy Technology Laboratory (NETL) of the DOE. During the first phase of the program, lasting approximately 3-4 years, a 5kW machine was designed, manufactured and tested against the specification developed by NETL. This unit was also shipped to NETL for independent verification testing which validated all of the results achieved while in the laboratory at Acumentrics. The Acumentrics unit passed all criteria established from operational stability, efficiency, and cost projections. Passing of the SECA Phase I test allowed the program to move into Phase II of the program. During this phase, the overall objective was to further refine the unit meeting a higher level of performance stability as well as further cost reductions. During the first year of this new phase, the NETL SECA program was refocused towards larger size units and operation on coal gasification due to the severe rise in natural gas prices and refocus on the US supply of indigenous coal. At this point, the program was shifted to the U.S. DOE’s Energy Efficiency and Renewable Energy (EERE) division located in Golden, Colorado. With this shift, the focus remained on smaller power units operational on gaseous fuels for a variety of applications including micro combined heat and power (mCHP). To achieve this goal, further enhancements in power, life expectancy and reductions in cost were necessary. The past 5 years have achieved these goals with machines that can now achieve over 40% electrical efficiency and field units that have now operated for close to a year and a half with minimal maintenance. The following report details not only the first phase while under the SECA program

  3. Inert-Gas Condensed Co-W Nanoclusters: Formation, Structure and Magnetic Properties

    Science.gov (United States)

    Golkar-Fard, Farhad Reza

    Rare-earth permanent magnets are used extensively in numerous technical applications, e.g. wind turbines, audio speakers, and hybrid/electric vehicles. The demand and production of rare-earth permanent magnets in the world has in the past decades increased significantly. However, the decrease in export of rare-earth elements from China in recent time has led to a renewed interest in developing rare-earth free permanent magnets. Elements such as Fe and Co have potential, due to their high magnetization, to be used as hosts in rare-earth free permanent magnets but a major challenge is to increase their magnetocrystalline anisotropy constant, K1, which largely drives the coercivity. Theoretical calculations indicate that dissolving the 5d transition metal W in Fe or Co increases the magnetocrystalline anisotropy. The challenge, though, is in creating a solid solution in hcp Co or bcc Fe, which under equilibrium conditions have negligible solubility. In this dissertation, the formation, structure, and magnetic properties of sub-10 nm Co-W clusters with W content ranging from 4 to 24 atomic percent were studied. Co-W alloy clusters with extended solubility of W in hcp Co were produced by inert gas condensation. The different processing conditions such as the cooling scheme and sputtering power were found to control the structural state of the as-deposited Co-W clusters. For clusters formed in the water-cooled formation chamber, the mean size and the fraction crystalline clusters increased with increasing power, while the fraction of crystalline clusters formed in the liquid nitrogen-cooled formation chamber was not as affected by the sputtering power. For the low W content clusters, the structural characterization revealed clusters predominantly single crystalline hcp Co(W) structure, a significant extension of W solubility when compared to the equilibrium solubility, but fcc Co(W) and Co3W structures were observed in very small and large clusters, respectively. At high

  4. Portable 25W hybrid fuel cell system

    International Nuclear Information System (INIS)

    Green, K.; Slee, R.; Tilley, J.

    2003-01-01

    Increased operating periods for portable electrical equipment are driving the development of battery and fuel cell technologies. Fuel cell systems promise greater endurance than battery based systems, and this paper describes the research into, and design of, a hybrid lithium-ion battery / fuel cell power source. The device is primarily aimed at military applications such as powering army radio sets and the UK MoD's Integrated Soldier Technology (IST) programme, but would be equally suitable as a power source for civilian applications such as camcorders, battery chargers etc. The air-breathing fuel cell comprises low cost, robust components, and a single cell is capable of developing >0.5W cm -2 . This power rating, however, is reduced in a stack where heat rejection becomes a critical issue. The stack design lends itself to facile manufacture, and the stack can be assembled in minutes by simply stacking the components into place. The remainder of the system includes two lithium-ion battery packs which provide start-up and shutdown power, and enable a silent-operating mode, during which the fuel cell is powered down, to be selected. The intelligent, electronic control, based upon an embedded RISC microprocessor, ensures safe operation and the recharge of the batteries. The overall system is capable of delivering 25W continuous power at an operating voltage of 12V dc. Preliminary testing results are reported. Advantages of this system include a relatively high gravimetric power density, load-following operation and the confidence of a high performance battery as an emergency backup. (author)

  5. Low power arcjet performance

    Science.gov (United States)

    Curran, Francis M.; Sarmiento, Charles J.

    1990-01-01

    An experimental investigation was performed to evaluate arcjet operation at low power. A standard, 1 kW, constricted arcjet was run using nozzles with three different constrictor diameters. Each nozzle was run over a range of current and mass flow rates to explore stability and performance in the low power regime. A standard pulse-width modulated power processor was modified to accommodate the high operating voltages required under certain conditions. Stable, reliable operation at power levels below 0.5 kW was obtained at efficiencies between 30 and 40 percent. The operating range was found to be somewhat dependent on constrictor geometry at low mass flow rates. Quasi-periodic voltage fluctuations were observed at the low power end of the operating envelope. The nozzle insert geometry was found to have little effect on the performance of the device. The observed performance levels show that specific impulse levels above 350 seconds can be obtained at the 0.5 kW power level.

  6. Power ramp tests of high burnup BWR segment rods

    International Nuclear Information System (INIS)

    Hayashi, H.; Etoh, Y.; Tsukuda, Y.; Shimada, S.; Sakurai, H.

    2002-01-01

    Lead use assemblies (LUAs) of high burnup 8x8 fuel design for Japanese BWRs were irradiated up to 5 cycles in Fukushima Daini Nuclear Power Station No. 2 Unit. Segment rods were installed in LUAs and used for power ramp tests in Japanese Material Test Reactor (JMTR). Post irradiation examinations (PIEs) of segment rods were carried out at Nippon Nuclear Fuel Development Co., Ltd. before and after ramp tests. Maximum linear heat rates of LUAs were kept above 300 W/cm in the first cycle, above 250 W/cm in the second and third cycles and decreased to 200 W/cm in the fourth cycle and 80 W/cm in the fifth cycle. The integrity of high burnup 8x8 fuel was confirmed up to the bundle burnup of 48 GWd/t after 5 cycles of irradiation. Systematic and high quality data were collected through detailed PIEs. The main results are as follows. The oxide on the outer surface of cladding tubes was uniform and its thickness was less than 20 micro-meter after 5 cycles of irradiation and was almost independent of burnup. Hydrogen contents in cladding tubes were less than 150 ppm after 5 cycles of irradiation, although hydrogen contents increased during the fourth and fifth irradiation cycles. Mechanical properties of cladding tubes were on the extrapolated line of previous data up to 5 cycles of irradiation. Fission gas release rates were in the low level (mainly less than 6%) up to 5 cycles of irradiation due to the design to decrease pellet temperature. Pellet-cladding bonding layers were observed after the third cycle and almost full bonding was observed after the fifth cycle. Pellet volume increased with burnup in proportion to solid swelling rate up to the forth cycle. After the fifth cycle, slightly higher pellet swelling was confirmed. Power ramp tests were carried out and satisfactory performance of Zr-lined cladding tube was confirmed up to 60 GWd/t (segment average burnup). One segment rod irradiated for 3 cycles failed by a single step ramp test at terminal ramp power of 614 W

  7. Poly(3,4-ethylenedioxythiophene) nanotubes as electrode materials for a high-powered supercapacitor

    International Nuclear Information System (INIS)

    Liu Ran; Cho, Seung Il; Lee, Sang Bok

    2008-01-01

    We report the fast charging/discharging capability of poly(3,4-ethylenedioxythiophene) (PEDOT) nanotubes during the redox process and their potential application to a high-powered supercapacitor. PEDOT nanotubes were electrochemically synthesized in a porous alumina membrane, and their structures were characterized using electron microscopes. Cyclic voltammetry was used to characterize the specific capacitance of the PEDOT nanotubes at various scan rates. A type I supercapacitor (two symmetric electrodes) based on PEDOT nanotube electrodes was fabricated, and its energy density and power density were evaluated by galvanostatic charge/discharge cycles at various current densities. We show that the PEDOT-nanotube-based supercapacitor can achieve a high power density of 25 kW kg -1 while maintaining 80% energy density (5.6 W h kg -1 ). This high power capability is attributed to the fast charge/discharge of nanotubular structures: hollow nanotubes allow counter-ions to readily penetrate into the polymer and access their internal surfaces, while the thin wall provides a short diffusion distance to facilitate the ion transport. Impedance spectroscopy shows that nanotubes have much lower diffusional resistance to charging ions than solid nanowires shielded by an alumina template, providing supporting information for the high charging/discharging efficiency of nanotubular structures

  8. Zmiany w stawie szczytowo-obrotowym u chorych na reumatoidalne zapalenie stawów – badanie obserwacyjne

    Directory of Open Access Journals (Sweden)

    Anna Raczkiewicz

    2010-10-01

    Full Text Available Wstęp: Zmiany zapalne w kręgosłupie szyjnym występują u 25–80% chorych na reumatoidalne zapalenie stawów (RZS. W większościbadań podkreśla się brak związku między zgłaszanymi dolegliwościamia zmianami radiologicznymi w kręgosłupie. Cel pracy: Ocena postępu zmian w stawie szczytowo-obrotowymu chorych na RZS oraz próba znalezienia związku między zgłaszanymiobjawami ze strony kręgosłupa a progresją zmian radiologicznych. Materiały i metody: Do badania zakwalifikowano 100 chorych naRZS. Chorych oceniano na początku badania i po upływie 5 lat.Na pierwsze badanie składało się wypełnienie 7-punktowegokwestionariusza dotyczącego objawów bólowych lub sugerującychmielopatię, badanie przez lekarza neurologa oraz czynnościowezdjęcia kręgosłupa szyjnego uzupełnione o wynik badaniatomografii komputerowej i/lub rezonansu magnetycznego tegoodcinka. Po 5 latach ponownie przeprowadzono badanie kwestionariuszowe,badanie neurologiczne i zdjęcia radiologiczne. Wyniki: U połowy chorych stwierdzono obecność zmian w stawieszczytowo-obrotowym na początku badania. Nie znaleziono korelacjitych zmian z subiektywnymi objawami. Ponownemu badaniu poddano47 chorych. Progresję zmian radiologicznych stwierdzonou 23,4% z nich (u 10,6% pogorszenie, a u 12,8% nowe zmiany. U chorychz progresją zmian stwierdzono utrzymującą się wysoką aktywnośćchoroby w porównaniu z chorymi, którzy nie wykazywaliprogresji, i częściej stwierdzano u nich zmiany radiologiczne odpowiadająceIII lub IV okresowi wg Steinbrockera (p < 0,05. U chorychz progresją zmian obserwowano tendencję do wyższej punktacji w drugim badaniu kwestionariuszowym w porównaniu z chorymizaliczonymi do grupy bez progresji (p = 0,09. Wnioski: Ryzyko progresji zmian w stawie szczytowo-obrotowymjest większe u chorych z utrzymującą się wysoką aktywnością choroby.Powtórne badanie kwestionariuszowe subiektywnych objawówmoże być wskazówką do powtórzenia bada

  9. Transepithelial resistance and claudin expression in trout RTgill-W1 cell line

    DEFF Research Database (Denmark)

    T. Trubitt, Rebecca; Rabeneck, D. Brett; Bujak, Joanna

    2015-01-01

    In the present study, we examined the trout gill cell line RTgill-W1 as a possible tool for in vitro investigation of epithelial gill function in fish. After seeding in transwells, transepithelial resistance (TER) increased until reaching a plateau after 1–2 days (20–80 Ω⋅cm2), which was then mai......In the present study, we examined the trout gill cell line RTgill-W1 as a possible tool for in vitro investigation of epithelial gill function in fish. After seeding in transwells, transepithelial resistance (TER) increased until reaching a plateau after 1–2 days (20–80 Ω⋅cm2), which...... was then maintained for more than 6 days. Tetrabromocinnamic acid, a known stimulator of TER via casein kinase II inhibition, elevated TER in the cell line to 125% of control values after 2 and 6 h. Treatment with ethylenediaminetetraacetic acid induced a decrease in TER to b15% of pre-treatment level. Cortisol...... detected Cldn-10e and Cldn-30 immunoreactive proteins of expected molecular weight in samples from rainbow trout gills but not from RTgill-W1 cultures, possibly due to low expression levels. Collectively, these results show that the RTgill-W1 cell layers have tight junctions between cells, are sensitive...

  10. Zastosowanie artefaktu świetlika w ultrasonograficznej diagnostyce kamicy moczowej

    Directory of Open Access Journals (Sweden)

    Małgorzata Placzyńska

    2013-04-01

    Full Text Available Artefakt świetlika jest zjawiskiem stosowanym w diagnostyce ultrasonograficznej przy użyciu kolorowego Dopplera. Obraz artefaktu świetlika zależy w dużym stopniu od ustawienia aparatu. Zwykle uwydatnia się przy niskich częstotliwościach transmitowanej wiązki ultradźwiękowej i wysokich ustawieniach skali Dopplera. Mimo coraz szerszego zastosowania w diagnostyce ultrasonograficznej artefakt ten wciąż pozostaje zjawi‑ skiem mało znanym. Bywa pomocny w rozpoznawaniu kamicy pęcherzyka żółciowego i dróg żółciowych, ade‑ nomiomatozy pęcherzyka żółciowego oraz wszelkich zwapnień w innych narządach. Przy jego użyciu można też stwierdzić obecność gazów w jelitach czy metalowych ciał obcych. Najczęściej jednak artefakt migotania wykorzystywany jest do identyfikacji złogów w drogach moczowych. W porównaniu z badaniem radiologicz‑ nym jamy brzusznej i urografią badanie ultrasonograficzne z zastosowaniem artefaktu świetlika pozwala na wykrycie około 80% przypadków kamicy układu moczowego. Charakter struktury złogu, jego chropowa‑ tość i wielkość są najważniejszymi elementami uczestniczącymi w tworzeniu tego zjawiska. Artefakt migota‑ nia umożliwia wczesne wykrycie złogów, które nie dają cienia akustycznego, złogów małych rozmiarów oraz tych zlokalizowanych w moczowodzie. Przypuszcza się, że obecność lub brak migoczącego artefaktu koreluje również ze składem chemicznym kamienia. Badanie ultrasonograficzne z jednoczesnym zastosowaniem arte‑ faktu świetlika powinno być procedurą wstępną w rozpoznawaniu kamicy układu moczowego, monitorowa‑ niu ewolucji złogów oraz ocenie wydalania złogów poddawanych zabiegom ESWL.

  11. Design study of wind turbines, 50 kW to 3000 kW for electric utility applications: Executive summary

    Science.gov (United States)

    1977-01-01

    Preliminary designs of low power (50 to 500 kW) and high power (500 to 3000 kW) wind generator systems (WGS) for electric utility applications were developed. These designs provide the bases for detail design, fabrication, and experimental demonstration testing of these units at selected utility sites. Several feasible WGS configurations were evaluated, and the concept offering the lowest energy cost potential and minimum technical risk for utility applications was selected. The selected concept was optimized utilizing a parametric computer program prepared for this purpose. The utility requirements evaluation task examined the economic, operational and institutional factors affecting the WGS in a utility environment, and provided additional guidance for the preliminary design effort. Results of the conceptual design task indicated that a rotor operating at constant speed, driving an AC generator through a gear transmission is the most cost effective WGS configuration.

  12. Operational stability of a compact 600-W KrF laser

    International Nuclear Information System (INIS)

    Borisov, V M; Vinokhodov, A Yu; Vodchits, V A; El'tsov, A V; Basting, D; Stamm, U; Voss, F

    1998-01-01

    The problem of the operational stability of a KrF laser with an average output power of at least 600 W was investigated. An experimental study was made of the dependences of the rms deviation σ of the output energy on the charging voltage, on the pulse repetition rate, and on the operating time. The value of σ varied from 1.2% to 6.0%, depending on the experimental conditions. For an average power of ∼ 600 W, the deviation σ did not exceed 3.2%. (lasers and amplifiers)

  13. Akt regulates drug-induced cell death through Bcl-w downregulation.

    Science.gov (United States)

    Garofalo, Michela; Quintavalle, Cristina; Zanca, Ciro; De Rienzo, Assunta; Romano, Giulia; Acunzo, Mario; Puca, Loredana; Incoronato, Mariarosaria; Croce, Carlo M; Condorelli, Gerolama

    2008-01-01

    Akt is a serine threonine kinase with a major role in transducing survival signals and regulating proteins involved in apoptosis. To find new interactors of Akt involved in cell survival, we performed a two-hybrid screening in yeast using human full-length Akt c-DNA as bait and a murine c-DNA library as prey. Among the 80 clones obtained, two were identified as Bcl-w. Bcl-w is a member of the Bcl-2 family that is essential for the regulation of cellular survival, and that is up-regulated in different human tumors, such as gastric and colorectal carcinomas. Direct interaction of Bcl-w with Akt was confirmed by immunoprecipitation assays. Subsequently, we addressed the function of this interaction: by interfering with the activity or amount of Akt, we have demonstrated that Akt modulates the amount of Bcl-w protein. We have found that inhibition of Akt activity may promote apoptosis through the downregulation of Bcl-w protein and the consequential reduction in interaction of Bcl-w with pro-apoptotic members of the Bcl-2 family. Our data provide evidence that Bcl-w is a new member of the Akt pathway and that Akt may induce anti-apoptotic signals at least in part through the regulation of the amount and activity of Bcl-w.

  14. Cohort study comparing prostate photovaporisation with XPS 180W and HPS 120W laser.

    Science.gov (United States)

    López, B; Capitán, C; Hernández, V; de la Peña, E; Jiménez-Valladolid, I; Guijarro, A; Pérez-Fernández, E; Llorente, C

    2016-01-01

    Prostate photovaporisation with Greenlight laser for the surgical treatment of benign prostate hyperplasia has rapidly evolve to the new XPS 180W. We have previously demonstrated the safety and efficacy of the HPS 120W. The aim of this study was to assess the functional and safety results, with a year of follow-up, of photovaporisation using the XPS 180W laser compared with its predecessor. A cohort study was conducted with a series of 191 consecutive patients who underwent photovaporisation between 1/2008 and 5/2013. The inclusion criteria were an international prostate symptom score (IPSS) >15 after medical failure, a prostate volume <80 cm(3) and a maximum flow <15 mL/s. We assessed preoperative and intraoperative variables (energy used, laser time and total surgical time), complications, catheter hours, length of stay and functional results (maximum flow, IPSS, prostate-specific antigen and prostate volume) at 3, 6 and 12 months. We analysed the homogeneity in preoperative characteristics of the 2 groups through univariate analysis techniques. The postoperative functional results were assessed through an analysis of variance of repeated measures with mixed models. A total of 109 (57.1%) procedures were performed using HPS 120W, and 82 (42.9%) were performed using XPS. There were no differences between the preoperative characteristics. We observed significant differences both in the surgical time and effective laser time in favour of the XPS system. This advantage was 11% (48 ± 15.7 vs. 53.8 ± 16.2, p<.05) and 9% (32.8 ± 11.7 vs. 36 ± 11.6, p<.05), respectively. There were no statistically significant differences in the rest of the analysed parameters. The technical improvements in the XPS 180W system help reduce surgical time, maintaining the safety and efficacy profile offered by the HPS 120W system, with completely superimposable results at 1 year of follow-up. Copyright © 2015 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Angiogeneza w reumatoidalnym zapaleniu stawów

    Directory of Open Access Journals (Sweden)

    Anna Kotulska

    2011-02-01

    Full Text Available Angiogeneza jest procesem powstawania nowych włosowatychnaczyń krwionośnych z uprzednio istniejących włośniczek. Angiogenezawystępuje w życiu pozapłodowym i jest regulowana przezzespół czynników proangiogennych i antyangiogennych (tab. I.Zwiększona angiogeneza towarzyszy kilku stanom chorobowym. Jestniezbędna dla wzrostu nowotworów złośliwych. Choroby nienowotworowe,w tym reumatoidalne zapalenie stawów, są także związanez nasiloną angiogenezą. Wykazano tworzenie nowych naczyńw zmienionej zapalnie błonie maziowej stawów, co jest najważniejszązmianą patologiczną u chorych na reumatoidalne zapalenie stawów.U chorych stwierdzono zaburzoną regulację czynników proangiogennychi hamujących ten proces. Leki hamujące zapalenie błonymaziowej bezpośrednio lub pośrednio ograniczają angiogenezę.Możliwe jest, że oddziaływanie na proces angiogenezy będzie stanowićjeden z mechanizmów terapeutycznych leków stosowanychu chorych na reumatoidalne zapalenie stawów.

  16. Impact of applied ultrasonic power on the low temperature drying of apple.

    Science.gov (United States)

    Santacatalina, J V; Contreras, M; Simal, S; Cárcel, J A; Garcia-Perez, J V

    2016-01-01

    Low temperature drying (LTD) allows high-quality dried products to be obtained, preserving the nutritional properties of fresh foods better than conventional drying, but it is a time-consuming operation. Power ultrasound (US) could be used to intensify LTD, but it should be taken into account that process variables, such as the level of applied power, have an influence on the magnitude and extension of the ultrasonic effects. Therefore, the aim of this work was to assess the influence of the level of applied ultrasonic power on the LTD of apple, analyzing the drying kinetics and the quality of the dried product. For that purpose, apple (Malus domestica cv. Granny Smith) cubes (8.8mm side) were dried (2m/s) at two different temperatures (10 and -10°C), without and with (25, 50 and 75 W) US application. In the dried apple, the rehydration kinetics, hardness, total phenolic content, antioxidant capacity and microstructure were analyzed to evaluate the impact of the level of applied ultrasonic power. At both temperatures, 10 and -10°C, the higher the ultrasonic power level, the shorter the drying time; the maximum shortening of the drying time achieved was 80.3% (at -10°C and 75 W). The ultrasonic power level did not significantly (pfruits, like apple, with only a mild impact on the quality of the dried product. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Novel roaming and stationary tethered aerial robots for continuous mobile missions in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Gu, Beom W.; Choi, Su Y.; Rim, Chun T. [Dept. of Nuclear and Quantum Engineering, KAIST, Daejeon (Korea, Republic of); Choi, Young Soo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Cai, Guowei; Seneviratne, Lakmal [Dept. of Aerospace Engineering, Khalifa University, Abu Dhabi (United Arab Emirates)

    2016-08-15

    In this paper, new tethered aerial robots including roaming tethered aerial robots (RTARs) for radioactive material sampling and stationary tethered aerial robots (STARs) for environment monitoring are proposed to meet extremely-long-endurance missions of nuclear power plants. The flight of the proposed tethered aerial robots may last for a few days or even a few months as long as the tethered cable provides continuous power. A high voltage AC or DC power system was newly adopted to reduce the mass of the tethered cable. The RTAR uses a tethered cable spooled from the aerial robot and an aerial tension control system. The aerial tension control system provides the appropriate tension to the tethered cable, which is accordingly laid down on the ground as the RTAR roams. The STAR includes a tethered cable spooled from the ground and a ground tension control system, which enables the STAR to reach high altitudes. Prototypes of the RTAR and STAR were designed and successfully demonstrated in outdoor environments, where the load power, power type, operating frequency, and flight attitude of the RTAR and STAR were: 180 W, AC 100 kHz, and 20 m; and 300 W, AC or DC 100 kHz, and 80 m, respectively.

  18. Novel Roaming and Stationary Tethered Aerial Robots for Continuous Mobile Missions in Nuclear Power Plants

    Directory of Open Access Journals (Sweden)

    Beom W. Gu

    2016-08-01

    Full Text Available In this paper, new tethered aerial robots including roaming tethered aerial robots (RTARs for radioactive material sampling and stationary tethered aerial robots (STARs for environment monitoring are proposed to meet extremely-long-endurance missions of nuclear power plants. The flight of the proposed tethered aerial robots may last for a few days or even a few months as long as the tethered cable provides continuous power. A high voltage AC or DC power system was newly adopted to reduce the mass of the tethered cable. The RTAR uses a tethered cable spooled from the aerial robot and an aerial tension control system. The aerial tension control system provides the appropriate tension to the tethered cable, which is accordingly laid down on the ground as the RTAR roams. The STAR includes a tethered cable spooled from the ground and a ground tension control system, which enables the STAR to reach high altitudes. Prototypes of the RTAR and STAR were designed and successfully demonstrated in outdoor environments, where the load power, power type, operating frequency, and flight attitude of the RTAR and STAR were: 180 W, AC 100 kHz, and 20 m; and 300 W, AC or DC 100 kHz, and 80 m, respectively.

  19. Report on the results of the FY 1999 R and D of polymer electrolyte fuel cells. Development of the power system technology (Development of high voltage several 10 kW class dispersed generation system); 1999 nendo kotai kobunshigata nenryo denchi no kenkyu kaihatsu seika hokokusho. Hatsuden system gijutsu no kaihatsu (koden'atsugata suju kW kyu bunsan dengen system no kaihatsu)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    The paper described the results of the FY 1999 development of polymer electrolyte fuel cell and several 10 kW class dispersed generation system. The humidification of the cell body is the internal humidification method in which water is directly supplied to cell, which makes the cell life long. The cooling using latent heat of vaporization of the water supplied makes the temperature distribution inside the cell face homogeneous. In the test for long life, the system was stably operated at voltage lowering speed of 11mV/1000h. The optimization of water supply structure in the stack increases the latent heat cooling amount and makes the temperature distribution inside the cell face homogeneous. The reduction of CO concentration in reformed gas is extremely important for improvement of cell performance and long-term stabilization of cell voltage. By the two-stage structure selective oxidation device, the CO concentration at inlet, 5,000 ppm, can be reduced to below 10 ppm at outlet. In the demonstrative experiment on the several 10 kW class dispersed generation system, efforts for reduction in size of structural equipment and package were made, and a possible size of 200*150*180cm was obtained. Based on the chart of 30kW class system flow, the heat material balance was analyzed, and the power generation efficiency of 40% at a.c. sending end and overall efficiency of 80% were confirmed. (NEDO)

  20. Morphological and microstructural characterization of nanostructured pure α-phase W coatings on a wide thickness range

    Energy Technology Data Exchange (ETDEWEB)

    Gordillo, N., E-mail: nuri.gordillo@gmail.com [Instituto de Fusión Nuclear, ETSI de Industriales, Universidad Politécnica de Madrid, C/José Gutierrez Abascal, 2, E-28006 Madrid (Spain); CEI Campus Moncloa, UCM-UPM, Madrid (Spain); Panizo-Laiz, M. [Instituto de Fusión Nuclear, ETSI de Industriales, Universidad Politécnica de Madrid, C/José Gutierrez Abascal, 2, E-28006 Madrid (Spain); Tejado, E. [Department of Materials Science, Research Centre on Safety and Durability of Structures and Materials (CISDEM), UPM-CSIC, C/Profesor Aranguren s/n, E-28040 Madrid (Spain); Centro Nacional de Investigaciones Metalúrgicas, CENIM-CSIC, Madrid (Spain); Fernandez-Martinez, I. [Instituto de Energía Solar (IES), Universidad Politécnica de Madrid, Avenida Complutense s/n, E-28040 Madrid (Spain); Instituto de Microelectrónica de Madrid, IMM-CNM-CSIC, Isaac Newton 8 PTM, Tres Cantos, E-28760 Madrid (Spain); Rivera, A. [Instituto de Fusión Nuclear, ETSI de Industriales, Universidad Politécnica de Madrid, C/José Gutierrez Abascal, 2, E-28006 Madrid (Spain); Pastor, J.Y. [Department of Materials Science, Research Centre on Safety and Durability of Structures and Materials (CISDEM), UPM-CSIC, C/Profesor Aranguren s/n, E-28040 Madrid (Spain); Castro, C. Gómez de [Departamento de Física de Materiales, Facultad de CC. Químicas, Universidad Complutense de Madrid, Ciudad Universitaria s/n, E-28040 Madrid (Spain); and others

    2014-10-15

    Highlights: • Pure α-phase tungsten nanostructures were deposited by DC-magnetron sputtering. • Non-delaminated coatings were achieved at powers ≤50 W. • The coating thicknesses vary from 30 nm up to ∼4.0 μm. • The influence of the substrate on the coating properties was investigated. • We report on the morphological, microstructural and mechanical properties. - Abstract: Nanostructured tungsten (nanoW) coatings have been deposited by DC magnetron sputtering. First, the influence of the sputtering power on the adhesion of the coatings to the substrate was investigated by depositing coatings at powers varying from 30 up to 220 W. Non-delaminated coatings were achieved at powers ≤50 W. Second, the influence of coating thickness on the morphological, microstructural and mechanical properties was investigated for films deposited at 50 W with thicknesses varying from 30 nm up to ∼4.0 μm. SEM images reveal that all the films are highly compact, consisting of nanometer sized columns that grow perpendicular to the substrate. XRD data evidence that films are monophasic, being made of pure α-phase. All coatings show compressive stress and low micro-strain. Nanoindentation tests show that coatings have a hardness higher than that reported for coarse grained W. No significant dependence of the previous properties on coating thickness was observed. Finally, the influence of the substrate on coatings properties was studied, by depositing a W coating at a power of 50 W on a commercial steel substrate: no significant dependence was found.

  1. The effect of resting blood flow occlusion on exercise tolerance and W'.

    Science.gov (United States)

    Broxterman, Ryan M; Craig, Jesse C; Ade, Carl J; Wilcox, Samuel L; Barstow, Thomas J

    2015-09-15

    It has previously been postulated that the anaerobic work capacity (W') may be utilized during resting blood flow occlusion in the absence of mechanical work. We tested the hypothesis that W' would not be utilized during an initial range of time following the onset of resting blood flow occlusion, after which W' would be utilized progressively more. Seven men completed blood flow occlusion constant power severe intensity handgrip exercise to task failure following 0, 300, 600, 900, and 1,200 s of resting blood flow occlusion. The work performed above critical power (CP) was not significantly different between the 0-, 300-, and 600-s conditions and was not significantly different from the total W' available. Significantly less work was performed above CP during the 1,200-s condition than the 900-s condition (P W' available (P W' during resting blood flow occlusion did not begin until 751 ± 118 s, after which time W' was progressively utilized. The current findings demonstrate that W' is not utilized during the initial ∼751 s of resting blood flow occlusion, but is progressively utilized thereafter, despite no mechanical work being performed. Thus, the utilization of W' is not exclusive to exercise, and a constant amount of work that can be performed above CP is not the determining mechanism of W'. Copyright © 2015 the American Physiological Society.

  2. ECRH and W7-X: An intriguing pair

    Science.gov (United States)

    Erckmann, V.; Braune, H.; Gantenbein, G.; Jelonnek, J.; Kasparek, W.; Laqua, H. P.; Lechte, C.; Marushchenko, N. B.; Michel, G.; Plaum, B.; Thumm, M.; Weissgerber, M.; Wolf, R.; W7-X ECRH Teams

    2014-02-01

    The construction of the W7-X basic machine is almost completed and the device is approaching the commissioning phase. W7-X operation will be supported by ECRH working at 140 GHz in 2nd harmonic X- or O-mode with 10 MW cw power. Presently the activities at W7-X concentrate on the implementation of wall-armour, in-vessel components and diagnostics. The ECRH-system is in stand by with 5 out of 10 gyrotrons operational. The status of both, the W7-X device and the ECRH system is reported. Further R&D activities concentrate on extending the launching capability for sophisticated confinement investigations with remote steering launchers in a poloidal plane with weak magnetic field gradient.

  3. Development of 1 kW Stirling cryocooler using a linear compressor

    International Nuclear Information System (INIS)

    Ko, J; Kim, H; Hong, Y J; Yeom, H; In, S; Park, S J

    2015-01-01

    Cryogenic cooling systems for HTS electric power devices require a reliable and efficient high-capacity cryocooler. A Striling cryocooler with a linear compressor can be a good candidate. It has advantages of low vibration and long maintenance cycle compared with a kinematic-driven Stirling cryocooler. In this study, we developed a dual-opposed linear compressor of 12 kW electric input power with two 6 kW linear motors. Electrical performance of the fabricated linear compressor is verified by experimental measurement of thrust constant. The developed Stirling cryocooler has a gamma-type configuration. The piston and displacer are supported with a flexure spring. A slit-type heat exchanger is adopted for the cold and warm-end, and the generated heat is rejected by cooling water. In the cooling performance test, waveforms of voltage, current, displacement and pressure are obtained and their amplitude and phase difference are analysed. The developed cryocooler reaches 47.8 K within 23.4 min. with no-load. Heat load tests shows a cooling capacity of 440 W at 78.1 K with 6.45 kW of electric input power and 19.4 of % Carnot COP. (paper)

  4. Fault protection system in a 'regulated high voltage power supply (80 KV, 130A)' for neutral beam injector

    International Nuclear Information System (INIS)

    Patel, Paresh; Sumod, C.B.; Thakkar, Dipal

    2011-01-01

    Regulated High Voltage Power Supply (RHVPS) system has been developed at Institute for Plasma Research (IPR) for use with the Neutral Beam and RF applications. The highest ratings manufactured so far is 80 kV, 130 A. The system is developed in house and also being delivered at different research institutes for various applications. Since it is a multi megawatt output power system, and the loads have very low fault energy tolerant, fault protection system is mandatory. Protections are mandatory at each stage of conversion. Output fault protection is done in a variety of ways. Fast turn off at output is achieved and test results are discussed. Multi secondary transformers (5.6 MVA rating, with 40 outputs) are used in realising the power supply. These special transformers need protection even for over current at one secondary when the output fault current is not reflected to primaries to break the main circuit breaker. It becomes difficult to bifurcate fault in such situations. Special technique is applied to sense it. Electronic means are used for fast detection and tripping the system. This paper describes the basic RHVPS topology and test results along with presentation on the input and output fault protection systems. (author)

  5. Acceptance test report: Backup power system

    International Nuclear Information System (INIS)

    Cole, D.B.

    1996-01-01

    Acceptance Test Report for construction functional testing of Project W-030 Backup Power System. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. Backup power includes a single 125 KW diesel generator, three 10-kva uninterruptible power supply units, and all necessary control

  6. The Jefferson Lab High Power Light Source

    Energy Technology Data Exchange (ETDEWEB)

    James R. Boyce

    2006-01-01

    Jefferson Lab has designed, built and operated two high average power free-electron lasers (FEL) using superconducting RF (SRF) technology and energy recovery techniques. Between 1999-2001 Jefferson Lab operated the IR Demo FEL. This device produced over 2 kW in the mid-infrared, in addition to producing world record average powers in the visible (50 W), ultraviolet (10 W) and terahertz range (50 W) for tunable, short-pulse (< ps) light. This FEL was the first high power demonstration of an accelerator configuration that is being exploited for a number of new accelerator-driven light source facilities that are currently under design or construction. The driver accelerator for the IR Demo FEL uses an Energy Recovered Linac (ERL) configuration that improves the energy efficiency and lowers both the capital and operating cost of such devices by recovering most of the power in the spent electron beam after optical power is extracted from the beam. The IR Demo FEL was de-commissioned in late 2001 for an upgraded FEL for extending the IR power to over 10 kW and the ultraviolet power to over 1 kW. The FEL Upgrade achieved 10 kW of average power in the mid-IR (6 microns) in July of 2004, and its IR operation currently is being extended down to 1 micron. In addition, we have demonstrated the capability of on/off cycling and recovering over a megawatt of electron beam power without diminishing machine performance. A complementary UV FEL will come on-line within the next year. This paper presents a summary of the FEL characteristics, user community accomplishments with the IR Demo, and planned user experiments.

  7. Space Power Free-Piston Stirling Engine Scaling Study

    Science.gov (United States)

    Jones, D.

    1989-01-01

    The design feasibility study is documented of a single cylinder, free piston Stirling engine/linear alternator (FPSE/LA) power module generating 150 kW-electric (kW sub e), and the determination of the module's maximum feasible power level. The power module configuration was specified to be a single cylinder (single piston, single displacer) FPSE/LA, with tuning capacitors if required. The design requirements were as follows: (1) Maximum electrical power output; (2) Power module thermal efficiency equal to or greater than 20 percent at a specific mass of 5 to 8 kg/kW(sub e); (3) Heater wall temperature/cooler wall temperature = 1050 K/525 K; (4) Sodium heat-pipe heat transport system, pumped loop NaK (sodium-potassium eutectic mixture) rejection system; (5) Maximum power module vibration amplitude = 0.0038 cm; and (6) Design life = 7 years (60,000 hr). The results show that a single cylinder FPSE/LA is capable of meeting program goals and has attractive scaling attributes over the power range from 25 to 150 kW(sub e). Scaling beyond the 150 kW(sub e) power level, the power module efficiency falls and the power module specific mass reaches 10 kg/kW(sub e) at a power output of 500 kW(sub e). A discussion of scaling rules for the engine, alternator, and heat transport systems is presented, along with a detailed description of the conceptual design of a 150 kW(sub e) power module that meets the requirements. Included is a discussion of the design of a dynamic balance system. A parametric study of power module performance conducted over the power output range of 25 to 150 kW(sub e) for temperature ratios of 1.7, 2.0, 2.5, and 3.0 is presented and discussed. The results show that as the temperature ratio decreases, the efficiency falls and specific mass increases. At a temperature ratio of 1.7, the 150 kW(sub e) power module cannot satisfy both efficiency and specific mass goals. As the power level increases from 25 to 150 kW(sub e) at a fixed temperature ratio, power

  8. Shielding of the NBI boxes against W7-X magnetic stray fields

    Energy Technology Data Exchange (ETDEWEB)

    Kick, Manfred [Max-Planck-Institut fuer Plasmaphysik, Boltzmannstr. 2, D-85748 Garching (Germany)], E-mail: Kick@arcor.de; Sielanko, Juliusz [Maria Curie Sklodowska University, Pl. M. C. Sklodowskie 1, 20-031 Lublin (Poland); Heinemann, Bernd; Riedl, Rudolf; Speth, Eckehart; Staebler, Albrecht [Max-Planck-Institut fuer Plasmaphysik, Boltzmannstr. 2, D-85748 Garching (Germany)

    2009-06-15

    Neutral Beam Injection (NBI), besides ECRH, is foreseen as one of the main heating devices at the W7-X stellarator currently under construction at IPP Greifswald, Germany. In a final stage 20 MW of NBI heating power will be installed generated by two NBI boxes of the ASDEX Upgrade (AUG) type. Since magnetic fields generally affect the trajectories of charged particles, essentially all the NBI boxes - including ion sources, acceleration sections, neutralisers and deflection magnets - must be shielded against the stray fields of W7-X. In the magnetic stray fields of W7-X there exist significant radial and toroidal components whereas at tokamaks the vertical components are dominant. The power loads on the ion dump and the protecting structures of the deflecting magnets and the beam lines caused by residual beam ions, therefore, will be strongly different. Thus the shielding concept of AUG cannot simply be taken over, but must be carefully redesigned in order to remain below the critical power limits. New modelling calculations of the magnetic shielding, the ion trajectories and the resulting power loads have been carried out for the 'high iota' and 'low shear' experimental scenarios of W7-X. The fields taken for these calculations are modelled by averaging the calculated W7-X stray fields on the one hand, and by fields generated by two-hypothetical-planar coils perpendicular to the x-y plane, on the other hand. The shielding concept for W7-X mainly consist of iron plates in the outer side regions of the boxes and as little magnetic material as possible inside the boxes.

  9. Determination of W boson mass from the four quark decay in the DELPHI experiment at LEP; Mesure de la masse du boson W dans la desintegration a quatre quarks dans l'experience DELPHI au LEP

    Energy Technology Data Exchange (ETDEWEB)

    Duperrin, Arnaud [Universite Claude Bernard, 69 - Lyon (France)

    1999-04-20

    The accurate determination of W boson mass allows testing the coherence of standard model and imposing new constrains upon some of its parameters as for instance the Higgs boson mass. The W mass obtained by direct reconstruction of WW{yields}qq-bar qq-bar, was measured by means of the data recorded in 1997 and 1998 by DELPHI experimentat the center-of-mass energies 183 GeV and 189 GeV, for a total luminosity of 212 pb{sup -1} at the LEP collider of CERN. A neural network was used to label the signal what led to an efficiency and a selection accuracy of 86% and 80%, respectively. The number of the selected events among the data was 1710. By mass reconstruction, the jet multiplicity was let to vary free between four and eight jets. A new fast algorithm of kinematic fitting of the jets was developed to improve the mass resolution of the multi-jet events, by imposing the energy and momentum conservation. The association of jets has been carried out also by means of a neural network. The W boson mass was extracted starting from a probability fitting of the two-dimensional distribution provided by complete simulation and formed by the mean and the difference of two masses of W reconstructs. A technique of Monte Carlo re-weighting has been developed to obtain the simulation spectra for arbitrary M{sub W} values. The leading systematic uncertainties are studied by gathering a large number of e{sup +}e{sup -}{yields}Z{yields}qq-bar events and by merging them for obtaining events similar to the W pairs. The value of the W mass obtained from the data based on this probability is M{sub W} = 80.350{+-}0.099 (stat.) {+-} 0.038 (exp.) {+-} 0.056 (th.) {+-} 0.018 (LEP) GeV/c{sup 2}. This result is competitive and in good agreement with other determinations. The current world average mass of W boson is M{sub W} = 80.394 {+-} 0.042 GeV/c{sup 2}. This result, included in a global fitting of the electroweak data, constraints the standard Higgs boson to a mass lower than 262 Ge

  10. Use of Cad Systems in Testing the Collision of Underground Transportation Means / Zastosowanie systemów Cad w badaniach kolizyjności środków transportu podziemnego

    Science.gov (United States)

    Dudek, Marek

    2013-06-01

    A concept of use of CAD systems in testing collision of underground transportation means is presented. Reasons for undertaking this problem are given with end users identified. The concept of the system for collision analyses of transported loads is described. Examples of collision analysis during transportation of powered roof support are given. Presented system is designed to aid planning, organizational and training activities undertaken in management of transportation safety in mines. It will be also possible to use software resources, developed within the system as the didactic material as regards safe transportation process, which include hazards to the employees working in the area of transportation operations. Developed prototype of a system for testing the collision of underground transportation means was positively assessed by employees of the Coal Company, JSC - industrial partner of KOMAG. This prototype is continuously improved and adapted for commercial implementation in the selected coal mines. W pracy przedstawiono koncepcję zastosowania systemów CAD w badaniach kolizyjności środków transportu podziemnego. Określono przyczyny podjęcia tematu oraz zidentyfikowano końcowych użytkowników. Zaprezentowano koncepcję systemu do analiz kolizyjności transportowanych ładunków. Pokazano przykłady analizy kolizyjności podczas transportu sekcji obudowy zmechanizowanej. Przedstawiony system przeznaczony jest do wspomagania działań planistycznych, organizacyjnych i szkoleniowych podejmowanych w zarządzaniu bezpieczeństwem transportu w zakładach górniczych. Opracowane w ramach systemu zasoby programowe będzie można również wykorzystać jako materiał dydaktyczny z zakresu bezpieczeństwa pracy w transporcie, uwzględniający zagrożenia dla pracowników pracujących w bezpośredniej strefie prac transportowych. Opracowany prototyp systemu do badania kolizyjności środków transportu podziemnego został pozytywnie oceniony przez pracowników

  11. Operating experience with a 250 kW el molten carbonate fuel cell (MCFC) power plant

    Science.gov (United States)

    Bischoff, Manfred; Huppmann, Gerhard

    The MTU MCFC program is carried out by a European consortium comprising the German companies MTU Friedrichshafen GmbH, Ruhrgas AG and RWE Energie AG as well as the Danish company Energi E2 S/A. MTU acts as consortium leader. The company shares a license and technology exchange agreement with Fuel Cell Energy Inc., Danbury, CT, USA (formerly Energy Research Corp., ERC). The program was started in 1990 and covers a period of about 10 years. The highlights of this program to date are: Considerable improvements regarding component stability have been demonstrated on laboratory scale. Manufacturing technology has been developed to a point which enables the consortium to fabricate the porous components on a 250 cm 2 scale. Several large area stacks with 5000-7660 cm 2 cell area and a power range of 3-10 kW have been tested at the facilities in Munich (Germany) and Kyndby (Denmark). These stacks have been supplied by FCE. As far as the system design is concerned it was soon realized that conventional systems do not hold the promise for competitive power plants. A system analysis led to the conclusion that a new innovative design approach is required. As a result the "Hot Module" system was developed by the consortium. A Hot Module combines all the components of a MCFC system operating at the similar temperatures and pressures into a common thermally insulated vessel. In August 1997 the consortium started its first full size Hot Module MCFC test plant at the facilities of Ruhrgas AG in Dorsten, Germany. The stack was assembled in Munich using 292 cell packages purchased from FCE. The plant is based on the consortium's unique and proprietary "Hot Module" concept. It operates on pipeline natural gas and was grid connected on 16 August 1997. After a total of 1500 h of operation, the plant was intentionally shut down in a controlled manner in April 1998 for post-test analysis. The Hot Module system concept has demonstrated its functionality. The safety concept has been

  12. Potentials of wind power

    International Nuclear Information System (INIS)

    Bezrukikh, P.P.; Bezrukikh, P.P.

    2000-01-01

    The ecological advantages of the wind power facilities (WPF) are considered. The possibilities of small WPF, generating the capacity from 40 W up to 10 kW, are discussed. The basic technical data on the national and foreign small WPF are presented. The combined wind power systems are considered. Special attention is paid to the most perspective wind-diesel systems, which provide for all possible versions of the electro-power supply. Useful recommendations and information on the wind power engineering are given for those, who decided to build up a wind facility [ru

  13. 78 FR 63570 - Proposed Collection; Comment Request for Forms W-8BEN, W-8BEN-E, W-8ECI, W-8EXP, and W-8IMY

    Science.gov (United States)

    2013-10-24

    ... W-8BEN, W-8BEN-E, W-8ECI, W-8EXP, and W-8IMY AGENCY: Internal Revenue Service (IRS), Treasury..., the IRS is soliciting comments concerning Form W-8BEN, Certificate of Foreign Status of Beneficial Owner for United States Tax Withholding, Form W-8BEN-E, Certificate of Status of Beneficial Owner for...

  14. System 80+ licensing gears up

    International Nuclear Information System (INIS)

    Newman, R.

    1992-01-01

    ABB Combustion Engineering Nuclear Power's 1300MWe System 80+ TM Standard Plant Design has now entered the intensive stage of the US Nuclear Regulatory Commission (NRC)'s review process for design certification. The design is docketed under the NRC's new rule for certifying the designs of advanced reactors. It is one of two evolutionary Advanced Light Water Reactors (ALWRs) whose certification process is sponsored by the US DoE. (Author)

  15. Special Application Thermoelectric Micro Isotope Power Sources

    International Nuclear Information System (INIS)

    Heshmatpour, Ben; Lieberman, Al; Khayat, Mo; Leanna, Andrew; Dobry, Ted

    2008-01-01

    Promising design concepts for milliwatt (mW) size micro isotope power sources (MIPS) are being sought for use in various space and terrestrial applications, including a multitude of future NASA scientific missions and a range of military applications. To date, the radioisotope power sources (RPS) used on various space and terrestrial programs have provided power levels ranging from one-half to several hundred watts. In recent years, the increased use of smaller spacecraft and planned new scientific space missions by NASA, special terrestrial and military applications suggest the need for lower power, including mW level, radioisotope power sources. These power sources have the potential to enable such applications as long-lived meteorological or seismological stations distributed across planetary surfaces, surface probes, deep space micro-spacecraft and sub-satellites, terrestrial sensors, transmitters, and micro-electromechanical systems. The power requirements are in the range of 1 mW to several hundred mW. The primary technical requirements for space applications are long life, high reliability, high specific power, and high power density, and those for some special military uses are very high power density, specific power, reliability, low radiological induced degradation, and very low radiation leakage. Thermoelectric conversion is of particular interest because of its technological maturity and proven reliability. This paper summarizes the thermoelectric, thermal, and radioisotope heat source designs and presents the corresponding performance for a number of mW size thermoelectric micro isotope power sources

  16. An ultra low-power off-line APDM-based switchmode power supply with very high conversion efficiency

    DEFF Research Database (Denmark)

    Nielsen, Nils

    2001-01-01

    This article describes the results from the research work on design of a ultra low power off-line power supply with very high conversion efficiency. The input voltage is 230 VAC nominal and output voltage is 5 VDC. By ultra low power levels, an output power level in the area ranging from 50 m......W and up to 1000 mW is meant. The small power supply is intended for use as a standby power supply in mains operated equipment, which requires a small amount of power in standby mode....

  17. Review of 2 kW grid connected LOPF tests in Nissum Bredning

    DEFF Research Database (Denmark)

    Margheritini, Lucia

    This report has been prepared by Per Resen and Aalborg University for the ForskVE project 10878: 2 kW grid connected LOPF test buoy. AAU has the role of reviewing and advise on the data analysis, besides compiling this report. The purpose of this project was to document the mechanical power...... production against a target power curve of a 2kW grid connected wave energy buoy in Nissum Bredning at Helligsø....

  18. Space Station power system issues

    International Nuclear Information System (INIS)

    Giudici, R.J.

    1985-01-01

    Issues governing the selection of power systems for long-term manned Space Stations intended solely for earth orbital missions are covered briefly, drawing on trade study results from both in-house and contracted studies that have been conducted over nearly two decades. An involvement, from the Program Development Office at MSFC, with current Space Station concepts began in late 1982 with the NASA-wide Systems Definition Working Group and continued throughout 1984 in support of various planning activities. The premise for this discussion is that, within the confines of the current Space Station concept, there is good reason to consider photovoltaic power systems to be a venerable technology option for both the initial 75 kW and 300 kW (or much greater) growth stations. The issue of large physical size required by photovoltaic power systems is presented considering mass, atmospheric drag, launch packaging and power transmission voltage as being possible practicality limitations. The validity of searching for a cross-over point necessitating the introduction of solar thermal or nuclear power system options as enabling technologies is considered with reference to programs ranging from the 4.8 kW Skylab to the 9.5 gW Space Power Satellite

  19. Comparative study of Ce0.80Sm0.20 Ba0.80Y0.20O3-δ (YB-SDC) electrolyte by various chemical synthesis routes

    Science.gov (United States)

    Tariq, Sana; Marium, Aniqa; Raza, Rizwan; Ashfaq Ahmad, M.; Ajmal Khan, M.; Abbas, Ghazanfar; Waseem Boota, M.; Khalid Imran, S.; Arshad, Sarfraz; Ikram, Muhammad

    2018-03-01

    Solid Oxide Fuel Cells is received a significant attention in recent years due to higher efficiency and fuel flexibility. The one of the main challenge for SOFC is to lower the operating temperature of SOFCs. Therefore, different strategies are used in order to enhance the ionic conduction of electrolyte, which can lower the overall SOFC operating temperature. The present work is focused on this strategy to enhance the electrolytic conductivity. Therefore, the ceria based composite electrolytes Ce0.80Sm0.20B0.80Y0.20O3-δ (YBSDC) are synthesized using three different approaches i.e. co-precipitation (YBSDC-1), sol-gel (YBSDC-2) and ball milling (YBSDC-3). Their crystal structures and surface morphologies are characterized through X-ray Diffraction (XRD) and Scanning Electron Microscopy (SEM) techniques, respectively. The four-probe technique is employed to measure their dc conductivities in the temperature range (300-700) °C under air atmosphere. The open circuit voltage (OCV) and current are recorded with natural gas as fuel {flow rate kept at 100 ml min-1 at 1 atm pressure} over the temperature range (300-600) °C. The electrolyte (YBSDC-1) prepared by co-precipitation technique is shown better results as compare to other two electrolytes (YBSDC-2 and YBSDC-3). The electrolyte (YBSDC-1) having maximum dc conductivity (0.096 S/cm), peak power density 224 mW cm-2 and OCV 0.94 V at 600 °C. These results show that YBSDC-1electrolyte is potential candidate for low temperature SOFCs.

  20. Diode-side-pumped 131 W, 1319 nm single-wavelength cw Nd:YAG laser.

    Science.gov (United States)

    Haiyong, Zhu; Ge, Zhang; Chenghui, Huang; Yong, Wei; Lingxiong, Huang; Jing, Chen; Weidong, Chen; Zhenqiang, Chen

    2007-01-20

    A diode-side-pumped high-power 1319 nm single-wavelength Nd:YAG continuous wave (cw) laser is described. Through reasonable coating design of the cavity mirrors, the 1064 nm strongest line as well as the 1338 nm one have been successfully suppressed. The laser output powers corresponding to four groups of different output couplers operating at 1319 nm single wavelength have been compared. The output coupler with the transmission T=5.3% has the highest output power, and a 131 W cw output power was achieved at the pumping power of 555 W. The optical-optical conversion efficiency is 23.6%, and the slope efficiency is 46%. The output power is higher than the total output power of the dual-wavelength laser operating at 1319 nm and 1338 nm in the experiment.

  1. Firmy rodzinne w Polsce w dobie globalizacji

    OpenAIRE

    Zalewska, Agnieszka

    2016-01-01

    Celem publikacji jest ukazanie dorobku naukowego, głównie polskich i ukraińskich uczonych, w zakresie uwarunkowań procesów i rezultatów internacjonalizacji przedsiębiorstw oraz jej wpływu na funkcjonowanie biznesu w dobie globalizacji. Opracowanie stanowi istotny wkład w zakresie teorii i praktyki w proces restrukturyzacji przedsiębiorstw w kierunku ich internacjonalizacji. Może posłużyć jako inspiracja do stworzenia strategii opartej na poszukiwaniach (prospector strategy), co będzie sprzyja...

  2. Lectures on W algebras and W gravity

    International Nuclear Information System (INIS)

    Pope, C.N.

    1992-01-01

    We give a review of the extended conformal algebras, known as W algebras, which contain currents of spins higher than 2 in addition to the energy-momentum tensor. These include the non-linear W N algebras; the linear W ∞ and W 1+∞ algebras; and their super-extensions. We discuss their applications to the construction of W-gravity and W-string theories. (author). 46 refs

  3. Hybrid Engine Powered City Car: Fuzzy Controlled Approach

    Science.gov (United States)

    Rahman, Ataur; Mohiuddin, AKM; Hawlader, MNA; Ihsan, Sany

    2017-03-01

    This study describes a fuzzy controlled hybrid engine powered car. The car is powered by the lithium ion battery capacity of 1000 Wh is charged by the 50 cc hybrid engine and power regenerative mode. The engine is operated with lean mixture at 3000 rpm to charge the battery. The regenerative mode that connects with the engine generates electrical power of 500-600 W for the deceleration of car from 90 km/h to 20 km/h. The regenerated electrical power has been used to power the air-conditioning system and to meet the other electrical power. The battery power only used to propel the car. The regenerative power also found charging the battery for longer operation about 40 minutes and more. The design flexibility of this vehicle starts with whole-vehicle integration based on radical light weighting, drag reduction, and accessory efficiency. The energy efficient hybrid engine cut carbon dioxide (CO2) and nitrogen oxides (N2O) emission about 70-80% as the loads on the crankshaft such as cam-follower and its associated rotating components are replaced by electromagnetic systems, and the flywheel, alternator and starter motor are replaced by a motor generator. The vehicle was tested and found that it was able to travel 70 km/litre with the power of hybrid engine.

  4. An Improved W Boson Mass Measurement Using the Collider Detector at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Yu [Duke Univ., Durham, NC (United States)

    2012-01-01

    The mass of the W boson is one of the most important parameters in the Standard Model. A precise measurement of the W boson mass, together with a precise measurement of the top quark mass, can constrain the mass of the undiscovered Higgs boson within the Standard Model framework or give a hint for physics beyond the Standard Model. This dissertation describes a measurement of the W boson mass through its decay into a muon and a neutrino using ~ 2.2 fb-1 of √ s = 1.96 TeV p$\\bar{p}$ data taken with the CDF II detector at Fermilab. We measure the W boson mass to be (80.374 ± 0.015stat. ± 0.016syst.) GeV/c2. This result, when combined with the W mass measurement in the electron channel, leads to the single most precise mW value and greatly constrains the possible mass range of the undiscovered Higgs boson. iv

  5. A Search for Non-Standard Model $W$ Helicity in Top Quark Decays

    Energy Technology Data Exchange (ETDEWEB)

    Kilminster, Benjamin John [Univ. of Rochester, NY (United States)

    2004-01-01

    The structure of the tbW vertex is probed by measuring the polarization of the W in t → W + b → l + v + b. The invariant mass of the lepton and b quark measures the W decay angle which in turn allows a comparison with polarizations expected from different possible models for the spin properties of the tbW interaction. We measure the fraction by rate of Ws produced with a V + A coupling in lieu of the Standard Model V-A to be fV + A = [special characters omitted] (stat) ± 0.21 (sys). We assign a limit of fV + A < 0.80 @ 95% Confidence Level (CL). By combining this result with a complementary observable in the same data, we assign a limit of fV + A < 0.61 @ 95% CL. We find no evidence for a non-Standard Model tbW vertex.

  6. Development of an MMS/PC based real time simulation of the B and W NSS plant for advanced control system design

    International Nuclear Information System (INIS)

    Bartells, P.S.; Brownell, R.B.

    1990-01-01

    The development of this personal-computer-based simulation of the Babcock and Wilcox nuclear steam system (NSS) was prompted in part by the need for a real-time analysis tool to be used in evaluating advanced control concepts for the NSS. NSS control is currently accomplished via conventional analog systems that are becoming increasingly obsolete. With the widespread use of digital micro-processor-based control systems for fossil power and other applications, the B and W Owners Group Advanced Control System Task Force is developing a next-generation control system for upgrading existing B and W power plants. To take advantage of the digital control technology, it is desirable to have a flexible, cost-effective, and portable control analysis tool available that can simulate various postulated control strategies and algorithms and couple these with simulated plant responses in real time to determine overall effectiveness. To develop the desired capability, B and W has incorporated the simulation methodology of the Modular Modeling System (MMS) and the knowledge gained during development of a similar Department of Energy-funded project. The MMS-based NSS model was developed and then modified to increase execution speed, ported to an IBM Personal System 2 (Model 80) and interfaced with user-friendly graphics. The user can develop alternative control strategies and readily interface them with the NSS model for real-time display and evaluation. The paper addresses the key considerations and programming techniques used to accomplish the resulting simulation

  7. Thermal management for high power lithium-ion battery by minichannel aluminum tubes

    International Nuclear Information System (INIS)

    Lan, Chuanjin; Xu, Jian; Qiao, Yu; Ma, Yanbao

    2016-01-01

    Highlights: • A new design of minichannel cooling is developed for battery thermal management system. • Parametric studies of minichannel cooling for a cell are conducted at different discharge rates. • Minichannel cooling can maintain almost uniform temperature (T_d_i_f_f < 1 °C). • Pumping power assumption is only about 5 milliwatt. - Abstract: Lithium-ion batteries are widely used for battery electric (all-electric) vehicles (BEV) and hybrid electric vehicles (HEV) due to their high energy and power density. An battery thermal management system (BTMS) is crucial for the performance, lifetime, and safety of lithium-ion batteries. In this paper, a novel design of BTMS based on aluminum minichannel tubes is developed and applied on a single prismatic Li-ion cell under different discharge rates. Parametric studies are conducted to investigate the performance of the BTMS using different flow rates and configurations. With minichannel cooling, the maximum cell temperature at a discharge rate of 1C is less than 27.8 °C, and the temperature difference across the cell is less than 0.80 °C using flow rate at 0.20 L/min, at the expense of 8.69e-6 W pumping power. At higher discharge rates, e.g., 1.5C and 2C, higher flow rates are required to maintain the same temperature rise and temperature difference. The flow rate needed is 0.8 L/min for 1.5C and 2.0 L/min for 2C, while the required pumping power is 4.23e-4 W and 5.27e-3 W, respectively. The uniform temperature distribution (<1 °C) inside the single cell and efficient pumping power demonstrate that the minichannel cooling system provides a promising solution for the BTMS.

  8. Smartphone application for emergency signal detection.

    Science.gov (United States)

    Figueiredo, Isabel N; Leal, Carlos; Pinto, Luís; Bolito, Jason; Lemos, André

    2016-09-01

    Currently, a number of studies focus on the study and design of new healthcare technologies to improve elderly health and quality of life. Taking advantage of the popularity, portability, and inherent technology of smartphones, we present an emergency application for smartphones, designated as knock-to-panic (KTP). This innovative and novel system enables users to simply hit their devices in order to send an alarm signal to an emergency service. This application is a complete and autonomous emergency system, and can provide an economic, reliable, and unobtrusive method for elderly monitoring or safety protection. Moreover, the simple and fast activation of KTP makes it a viable and potentially superior alternative to traditional ambient assisted living emergency calls. Furthermore, KTP can be further extended to the general population as well and not just be limited for elderly persons. The proposed method is a threshold-based algorithm and is designed to require a low battery power consumption. The evaluation of the performance of the algorithm in collected data indicates that both sensitivity and specificity are above 90%. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  9. 29 CFR Appendix A to Subpart W to... - Figures W-14 through W-28

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Figures W-14 through W-28 A Appendix A to Subpart W to part 1926 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION...; Overhead Protection Pt. 1926, Subpt. W, App. A Appendix A to Subpart W to part 1926—Figures W-14 through W...

  10. Rf power systems for the national synchrotron light source

    International Nuclear Information System (INIS)

    Dickinson, T.; Rheaume, R.H.

    1981-01-01

    The booster synchrotron and the two storage rings at the NSLS are provided with rf power systems of 3 kW, 50 kW, and 500 kW nominal output power, all at 53 MHz. This power is supplied by grounded grid tetrode amplifiers designed for television broadcast service. These amplifiers and associated power supplies, control and interlock systems, rf controls, and computer interface are described

  11. Electrodynamic Wireless Power Transmission to Rotating Magnet Receivers

    International Nuclear Information System (INIS)

    Garraud, A; Jimenez, J D; Garraud, N; Arnold, D P

    2014-01-01

    This paper presents an approach for electrodynamic wireless power transmission (EWPT) using a synchronously rotating magnet located in a 3.2 cm 3 receiver. We demonstrate wireless power transmission up to 99 mW (power density equal to 31 mW/cm 3 ) over a 5-cm distance and 5 mW over a 20-cm distance. The maximum operational frequency, and hence maximal output power, is constrained by the magnetic field amplitude. A quadratic relationship is found between the maximal output power and the magnetic field. We also demonstrate simultaneous, power transmission to multiple receivers positioned at different locations

  12. Accuracy of W' Recovery Kinetics in High Performance Cyclists - Modelling Intermittent Work Capacity.

    Science.gov (United States)

    Bartram, Jason C; Thewlis, Dominic; Martin, David T; Norton, Kevin I

    2017-10-16

    With knowledge of an individual's critical power (CP) and W' the SKIBA 2 model provides a framework with which to track W' balance during intermittent high intensity work bouts. There are fears the time constant controlling the recovery rate of W' (τ W' ) may require refinement to enable effective use in an elite population. Four elite endurance cyclists completed an array of intermittent exercise protocols to volitional exhaustion. Each protocol lasted approximately 3.5-6 minutes and featured a range of recovery intensities, set in relation to athlete's CPs (DCP). Using the framework of the SKIBA 2 model, the τ W ' values were modified for each protocol to achieve an accurate W' at volitional exhaustion. Modified τ W ' values were compared to equivalent SKIBA 2 τ W ' values to assess the difference in recovery rates for this population. Plotting modified τ W ' values against DCP showed the adjusted relationship between work-rate and recovery-rate. Comparing modified τ W' values against the SKIBA 2 τ W' values showed a negative bias of 112±46s (mean±95%CL), suggesting athlete's recovered W' faster than predicted by SKIBA 2 (p=0.0001). The modified τ W' to DCP relationship was best described by a power function: τ W' =2287.2∗D CP -0.688 (R 2 = 0.433). The current SKIBA 2 model is not appropriate for use in elite cyclists as it under predicts the recovery rate of W'. The modified τ W' equation presented will require validation, but appears more appropriate for high performance athletes. Individual τ W' relationships may be necessary in order to maximise the model's validity.

  13. 5W intracavity frequency-doubled green laser for laser projection

    Science.gov (United States)

    Yan, Boxia; Bi, Yong; Li, Shu; Wang, Dongdong; Wang, Dongzhou; Qi, Yan; Fang, Tao

    2014-11-01

    High power green laser has many applications such as high brightness laser projection and large screen laser theater. A compact and high power green-light source has been developed in diode-pumped solid-state laser based on MgO doped periodically poled LiNbO3 (MgO:PPLN). 5W fiber coupled green laser is achieved by dual path Nd:YVO4/MgO:PPLN intra-cacity frequency-doubled. Single green laser maximum power 2.8W at 532nm is obtained by a 5.5W LD pumped, MgO:PPLN dimensions is 5mm(width)×1mm(thickness)×2mm(length), and the optical to optical conversion efficiency is 51%. The second LD series connected with the one LD, the second path green laser is obtained using the same method. Then the second path light overlap with the first path by the reflection mirrors, then couple into the fiber with a focus mirror. Dual of LD, Nd:YVO4, MgO:PPLN are placed on the same heat sink using a TEC cooling, the operating temperature bandwidth is about 12°C and the stablity is 5% in 96h. A 50×50×17mm3 laser module which generated continuous-wave 5 W green light with high efficiency and width temperature range is demonstrated.

  14. Akt regulates drug-induced cell death through Bcl-w downregulation.

    Directory of Open Access Journals (Sweden)

    Michela Garofalo

    Full Text Available Akt is a serine threonine kinase with a major role in transducing survival signals and regulating proteins involved in apoptosis. To find new interactors of Akt involved in cell survival, we performed a two-hybrid screening in yeast using human full-length Akt c-DNA as bait and a murine c-DNA library as prey. Among the 80 clones obtained, two were identified as Bcl-w. Bcl-w is a member of the Bcl-2 family that is essential for the regulation of cellular survival, and that is up-regulated in different human tumors, such as gastric and colorectal carcinomas. Direct interaction of Bcl-w with Akt was confirmed by immunoprecipitation assays. Subsequently, we addressed the function of this interaction: by interfering with the activity or amount of Akt, we have demonstrated that Akt modulates the amount of Bcl-w protein. We have found that inhibition of Akt activity may promote apoptosis through the downregulation of Bcl-w protein and the consequential reduction in interaction of Bcl-w with pro-apoptotic members of the Bcl-2 family. Our data provide evidence that Bcl-w is a new member of the Akt pathway and that Akt may induce anti-apoptotic signals at least in part through the regulation of the amount and activity of Bcl-w.

  15. Laser tissue welding in genitourinary reconstructive surgery: assessment of optimal suture materials.

    Science.gov (United States)

    Poppas, D P; Klioze, S D; Uzzo, R G; Schlossberg, S M

    1995-02-01

    Laser tissue welding in genitourinary reconstructive surgery has been shown in animal models to decrease operative time, improve healing, and decrease postoperative fistula formation when compared with conventional suture controls. Although the absence of suture material is the ultimate goal, this has not been shown to be practical with current technology for larger repairs. Therefore, suture-assisted laser tissue welding will likely be performed. This study sought to determine the optimal suture to be used during laser welding. The integrity of various organic and synthetic sutures exposed to laser irradiation were analyzed. Sutures studied included gut, clear Vicryl, clear polydioxanone suture (PDS), and violet PDS. Sutures were irradiated with a potassium titanyl phosphate (KTP)-532 laser or an 808-nm diode laser with and without the addition of a light-absorbing chromophore (fluorescein or indocyanine green, respectively). A remote temperature-sensing device obtained real-time surface temperatures during lasing. The average temperature, time, and total energy at break point were recorded. Overall, gut suture achieved significantly higher temperatures and withstood higher average energy delivery at break point with both the KTP-532 and the 808-nm diode lasers compared with all other groups (P welding appears to be between 60 degrees and 80 degrees C. Gut suture offers the greatest margin of error for KTP and 808-nm diode laser welding with or without the use of a chromophore.

  16. High power excimer laser

    International Nuclear Information System (INIS)

    Oesterlin, P.; Muckenheim, W.; Basting, D.

    1988-01-01

    Excimer lasers emitting more than 200 W output power are not commercially available. A significant increase requires new technological efforts with respect to both the gas circulation and the discharge system. The authors report how a research project has yielded a laser which emits 0.5 kW at 308 nm when being UV preionized and operated at a repetition rate of 300 Hz. The laser, which is capable of operating at 500 Hz, can be equipped with an x-ray preionization module. After completing this project 1 kW output power will be available

  17. Power assisted fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Jarvis, L P; Atwater, T B; Plichta, E J; Cygan, P J [US Army CECOM, Fort Monmouth, NJ (United States). Research Development and Engineering Center

    1998-02-01

    A hybrid fuel cell demonstrated pulse power capability at pulse power load simulations synonymous with electronics and communications equipment. The hybrid consisted of a 25.0 W Proton Exchange Membrane Fuel Cell (PEMFC) stack in parallel with a two-cell lead-acid battery. Performance of the hybrid PEMFC was superior to either the battery or fuel cell stack alone at the 18.0 W load. The hybrid delivered a flat discharge voltage profile of about 4.0 V over a 5 h radio continuous transmit mode of 18.0 W. (orig.)

  18. Hafty w sztambuchach Biblioteki Uniwersyteckiej w Poznaniu

    Directory of Open Access Journals (Sweden)

    Karolina Nowaczyk

    2011-01-01

    Full Text Available W artykule przedstawiono hafty znajdujące się w sztambuchach z XVIII i XIX wieku pochodzących ze zbiorów Biblioteki Uniwersyteckiej w Poznaniu. Omówione zostały zarówno technika wykonania haftów, jak i ich wartość artystyczna, a także znaczenie wskazanych przykładów dla historii hafciarstwa amatorskiego na ziemiach polskich. Artykuł jest jednocześnie próbą zwrócenia uwagi na istniejącą w tamtym okresie sztukę hafciarską o wyłącznie amatorskim charakterze oraz na kopiowanie i powtarzalność wzorów, co pozwala na określenie ich jako typowych dla danej epoki.

  19. Neuropeptide Kyotorphin (Tyrosyl-Arginine) has Decreased Levels in the Cerebro-Spinal Fluid of Alzheimer's Disease Patients: Potential Diagnostic and Pharmacological Implications.

    Science.gov (United States)

    Santos, Sara Matos; Garcia-Nimo, Laura; Sá Santos, Sónia; Tavares, Isaura; Cocho, José A; Castanho, Miguel A R B

    2013-01-01

    In Alzheimer's disease (AD), besides the characteristic deterioration of memory, studies also point to a higher pain tolerance in spite of sensibility preservation. A change in the normal tau protein phosphorylation is also characteristic of AD, which contributes to the pathogenesis of the disease and is useful in early diagnosis. Kyotorphin (KTP) is an endogenous analgesic dipeptide (Tyr-Arg) for which there is evidence of eventual neuroprotective and neuromodulatory properties. The objective of this work was to study the possible correlation between KTP and phosphorylated tau protein (p-tau) levels in cerebro-spinal fluid (CSF) samples of AD patients. CSF samples were collected from 25 AD patients and 13 age-matched controls (N), where p-tau and KTP levels were measured. We found a statistically significant difference between p-tau/KTP values in AD and N groups with an inverse correlation between p-tau and KTP values in AD samples. These results suggest that in the future KTP may be a candidate biomarker for neurodegeneration and may be a lead compound to be used pharmacologically for neuroprotection.

  20. The effect of bevacizumab (Avastin) treatment on epistaxis in hereditary hemorrhagic telangiectasia.

    Science.gov (United States)

    Simonds, Jana; Miller, Frank; Mandel, Jess; Davidson, Terence M

    2009-05-01

    Determine the effectiveness of treating epistaxis in hereditary hemorrhagic telangiectasia (HHT) with potassium titanyl phosphate (KTP) laser cautery combined with submucosal injection of 100 mg of bevacizumab. Retrospective pilot study. Bevacizumab was injected throughout the nasal cavity following KTP laser treatment in 10 patients (bevacizumab/KTP group) and compared to nine patients previously treated with KTP laser alone (KTP group). Epistaxis frequency and severity, blood transfusion requirement, intravenous iron supplementation, emergency department visit frequency, and quality of life within 1 month and 1 year pre- and postsurgery were analyzed. Benefit was defined as less than three nosebleeds per week, with less than 10 minutes to stop each nosebleed, and no blood transfusions. The pre- and postsurgery data were analyzed within and between the two groups. The groups were comparable in age and gender. Significant benefit was found in frequency of epistaxis (P epistaxis is superior to KTP laser treatment alone. It significantly decreases frequency and severity of nosebleeds and blood transfusion requirements, and significantly improves work ability and quality of life.

  1. Reliability and Sensitivity of the Power Push-up Test for Upper-Body Strength and Power in 6-15-Year-Old Male Athletes.

    Science.gov (United States)

    Gillen, Zachary M; Miramonti, Amelia A; McKay, Brianna D; Jenkins, Nathaniel D M; Leutzinger, Todd J; Cramer, Joel T

    2018-01-01

    Gillen, ZM, Miramonti, AA, McKay, BD, Jenkins, NDM, Leutzinger, TJ, and Cramer, JT. Reliability and sensitivity of the power push-up test for upper-body strength and power in 6-15-year-old male athletes. J Strength Cond Res 32(1): 83-96, 2018-The power push-up (PPU) test is an explosive upper-body test performed on a force plate and is currently being used in high school football combines throughout the United States. The purpose of this study was to quantify the reliability of the PPU test based on age and starting position (knees vs. toes) in young athletes. Sixty-eight boys (mean ± SD; age = 10.8 ± 2.0 years) were tested twice over 5 days. Boys were separated by age as 6-9 years (n = 16), 10-11 years (n = 26), and 12-15 years (n = 26). The PPU test was performed on a force plate while rotating from the knees vs. the toes. Measurements were peak force (PF, N), peak rate of force development (pRFD, N·s), average power (AP, W), and peak power (PP, W). Intraclass correlation coefficients (ICC2,1), SEMs, coefficients of variation (CVs), and minimum detectable changes (MDCs) were calculated to quantify reliability and sensitivity. Peak force from the knees in 10-15-year-olds, PF from the toes in 12-15-year-olds, and pRFD from the knees and toes in 12-15-year-olds were comparably reliable (ICC ≥ 0.84). Neither power measurements (AP or PP) for any age group, nor any measurements (PF, pRFD, AP, or PP) for the 6-9-year-olds were comparably reliable (ICC ≤ 0.74). When considering the reliable variables, PF was greater in the 12-15-year-olds than in 10-11-year-olds (p ≤ 0.05). In addition, in 12-15-year-olds, PF and pRFD were greater from the knees than from the toes (p ≤ 0.05). For reasons largely attributable to growth and development, the PPU test may be a reliable (ICC ≥ 0.80) and sensitive (CV ≤ 19%) measure of upper-body strength (PF), whereas pRFD was also reliable (ICC ≥ 0.80), but less sensitive (CV = 30-38%) in 10-15-year-old male athletes.

  2. The System 80+ standard plant design reduces operations and maintenance costs

    International Nuclear Information System (INIS)

    Chari, D.R.; Robertson, J.E.

    1998-01-01

    To be cost-competitive, nuclear power plants must maximize plant availability and minimize operations and maintenance (O and M) costs. A plant whose design supports these goals will generate more power at less cost and thereby have a lower unit generating cost. The ABB Combustion Engineering Nuclear Systems (ABB-CE) System 80+ Standard Nuclear Power Plant, rated at 1400 megawatts electric (MWe), is designed for high availability at reduced cost. To demonstrate that the duration of refueling outages, the major contributor to plant unavailability, can be shortened, ABB-CE developed a detailed plan that shows a System 80+ plant can safely perform a refueling and maintenance outage in 18 days. This is a significant reduction from the average current U.S. plant outages of 45 days, and is possible due to a two-part outage strategy: use System 80+ advanced system design features and relaxed technical specification (TS) time limits to shift some maintenance from outages to operating periods: and, use System 80+ structural, system, and component features, such as the larger operating floor, permanent pool seal, integral reactor head area cable tray system and missile shield, and longer life reactor coolant pump seals, to reduce the scope and duration of outage maintenance activities. Plant staffing level is the major variable, or controllable contributor to operations costs. ABB-CE worked with the Institute of Nuclear Power Operations (INPO) to perform detailed staffing analyses that show a System 80+ plant can be operated reliably with 30 percent less staff than currently operating nuclear plants of similar size. Safety was not sacrificed when ABB-CE developed the System 80+ refueling outage plan and staffing level. The outage plan was developed utilizing a defense-in-depth concept for shutdown safety. The defense in-depth concept is implemented via systematic control of outage risk evaluation (SCORE) cards. The SCORE cards identify primary and alternate means of

  3. The evaluation and calculation of production cross sections of {sup 18}F, {sup 77}Br and {sup 186}Re medical radioisotopes from {sup 18}O, {sup 77}Se and {sup 186}W(p,n) reactions up to 80 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Youxiang, Zhuang [Chinese Nuclear Data Center, Beijing, BJ (China)

    1996-06-01

    The medical radioisotopes are used for diagnostic and therapeutic purposes, as well as metabolism and physiological function researches in modern medicine. The major applications are of functional imaging using PET agents for {sup 18}F, various therapeutic pharmaceuticals via auger electrons for {sup 77}Br, cancers diagnosis and therapy for {sup 186}Re. The evaluations of experimental data and theoretical calculations for {sup 18}O, {sup 77}Se, {sup 187}W(p,n) reactions up to 80 MeV are presented and analysed. The recommended values for {sup 18}O(p,n){sup 18}F, {sup 77}Se(p,n){sup 77}Br and {sup 186}W(p,n){sup 186}Re reaction cross sections are given. (6 figs.).

  4. Sonochemically preparation and characterization of bimetallic Ni-Co/Al2O3-ZrO2 nanocatalyst: Effects of ultrasound irradiation time and power on catalytic properties and activity in dry reforming of CH4.

    Science.gov (United States)

    Mahboob, Salar; Haghighi, Mohammad; Rahmani, Farhad

    2017-09-01

    The catalytic performance of nanostructured Ni-Co/Al 2 O 3 -ZrO 2 catalysts, prepared by ultrasound-assisted impregnation method was examined in the dry reforming of methane. The effect of irradiation power and irradiation time have been studied by changing time (0, 20, 80min) and power of the sonication (30, 60, 90W) during the synthesis which resulted in different physiochemical properties of the nanocatalyst. The nanocatalysts were characterized by XRD, FESEM, PSD, EDX, TEM, TPR-H 2 , BET, FTIR and TG analyses. Based on the characterization results, ultrasound treatment endowed the sample with more uniform and smaller nanoparticles; higher surface area, stronger metal-support interaction and more homogenous dispersion. Moreover, the analyses exhibited smaller particles with higher surface area and less population of particle aggregates at longer and highly irradiated nanocatalysts. The nanocatalyst irradiated at 90W for 80min (the longest irradiation time and the most intense power) showed a uniform morphology and a very narrow particles size distribution. More than 65% of particles of this nanocatalyst were in the range of 10-30nm. Activity tests demonstrated that employing ultrasound irradiation during impregnation improves feed conversion and products yield, reaching values close to equilibrium. Among sonicated nanocatalysts, with increasing power and time of irradiation, the nanocatalyst represents higher activity. The superior performance amongst the various bimetallic catalysts tested was observed over the catalyst with 90W and 80min ultrasonic irradiation which is stable in 24h time on stream test. The excellent anti-coking performance of this bimetallic catalyst, confirmed by TG and FESEM analyses of spent catalyst, is closely related to the promoting effect of sonication on the metal-support interaction, Ni dispersion and particle size; and probably, the synergy between metallic species. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Position-insensitive long range inductive power transfer

    International Nuclear Information System (INIS)

    Kwan, Christopher H; Lawson, James; Yates, David C; Mitcheson, Paul D

    2014-01-01

    This paper presents results of an improved inductive wireless power transfer system for reliable long range powering of sensors with milliwatt-level consumption. An ultra-low power flyback impedance emulator operating in open loop is used to present the optimal load to the receiver's resonant tank. Transmitter power modulation is implemented in order to maintain constant receiver power and to prevent damage to the receiver electronics caused by excessive received voltage. Received power is steady up to 3 m at around 30 mW. The receiver electronics and feedback system consumes 3.1 mW and so with a transmitter input power of 163.3 W the receiver becomes power neutral at 4.75 m. Such an IPT system can provide a reliable alternative to energy harvesters for supplying power concurrently to multiple remote sensors

  6. Przydatność artroskopowej totalnej synowektomii w leczeniu wysiękowego zapalenia stawu kolanowego u chorych na reumatoidalne zapalenie stawów

    Directory of Open Access Journals (Sweden)

    Piotr Frąszczak

    2011-06-01

    Full Text Available Reumatoidalne zapalenie stawów (RZS to przewlekła immunologiczniezależna układowa choroba tkanki łącznej. Charakteryzujeją symetryczne i przewlekłe zapalenie błony maziowej. Obej -muje stawy obwodowe, a z dużych stawów najczęściej stawkolanowy. Oprócz leczenia farmakologicznego jedną z metod opera -cyjnych jest synowektomia. Ostatnio coraz większego znaczenianabiera artroskopowa totalna synowektomia z uwagi na mało -inwazyjność, dużą radykalność oraz skrócenie czasu terapii i rehabilitacji.Technika ta pozwala na dość dokładne usunięcie błonymaziowej z 4 portów artroskopowych, a wskazaniem są nawracającewysięki trwające 6 miesięcy.Celem pracy było przedstawienie wczesnych wyników i sku -teczności artroskopowej totalnej synowektomii wykonaneju chorych na RZS. Ocenie poddano chorych po artroskopowejtotalnej synowektomii stawu kolanowego wykonanej w KliniceReumoortopedii Instytutu Reumatologii w Warszawie w latach2005–2006. Okres obserwacji wynosił dwa lata. Badania prowa -dzono na podstawie opracowanych własnych kart badań, a ocenywyników dokonano na podstawie czynnościowych skal HSSi Lysholma. Do badania zgłosiło się 15 chorych z 21 osób opero -wanych. Ocenę czynnościową przeprowadzono w okresie od półroku do 2 lat po artroskopowej totalnej synowektomii. Stwier dzono,że wynik doskonały i dobry po operacji osiągnęło w tym okresie 80% badanych. Wyniki te są porównywalne z wynikami uzyskanymiprzez inne ośrodki zajmujące się tym problemem w Europie i naświecie. Artroskopowa totalna synowektomia umożliwia szybkiepodjęcie rehabilitacji i funkcji czynnościowej stawu, skraca czasleczenia i obniża jego koszty oraz redukuje dawki leków podstawowych(tab. I.

  7. Operational tests of the BNL 24.8 kW, 3.80K helium refrigerator

    International Nuclear Information System (INIS)

    Brown, D.P.; Farah, Y.; Gibbs, R.J.; Schlafke, A.P.; Sondericker, J.H.

    1986-01-01

    The BNL 24.8 kW refrigeration system is completely installed and major portions of the acceptance tests have been completed. So far, the equipment tested has performed at or above design levels. The room temperature helium compressor station has been completely tested and accepted. The two-stage oil injected screw compressor system exhibited an isothermal efficiency of 57% while delivering a helium flow in excess of 4400 g/s. Data on the performance of the make-up gas cryogenic purifier is also given. The refrigerator turbomachinery, 13 expanders and three cold compressors, has been tested at room temperature for mechanical integrity and control stability. The first cooldown to operating temperature will be attempted in late August, 1985

  8. Interaction of actinide ions with [NaP5W30O110]14- and [P2W18O62]6-

    International Nuclear Information System (INIS)

    Choppin, G.R.; Wall, D.E.

    2003-01-01

    Stability constants (log β 101 ) of Th 4+ , UO 2 2+ , NpO 2 + and Am 3+ with [NaP 5 W 30 O 110 ] 14- were determined by solvent extraction (μ = 0.1M NaCl) and found to be 6.18 ± 0.07, 3.80 ± 0.06, 2.98 ± 0.04, and 5.85 ± 0.05, respectively. The order of stability constants: Th 4+ > Am 3+ > UO 2 2+ > NpO 2 + is due to electrostatic repulsion between the actinyl oxygens and oxygens on the polyoxometalate surface. The order of stability constants for metal complexes with [P 2 W 18 O 62 ] 6- is Th 4+ > UO 2 2+ > Eu 3+ >NpO 2 + because the steric repulsion between actinyl oxygens and oxygens on polyoxometalate are less important. Enthalpies of complexation were measured by calorimetric titration of Th 4+ , UO 2 2+ , Nd 3+ with [NaP 5 W 30 O 110 ] 14- and [P 2 W 18 O 62 ] 6- . The results indicate that the conformation and charge distribution of the microscopic surface structures are important factors in the formation of pseudocolloids. (author)

  9. With power comes responsibility: motorcycle engine power and power-to-weight ratio in relation to accident risk.

    Science.gov (United States)

    Mattsson, Markus; Summala, Heikki

    2010-02-01

    Current European legislation allows the EU member states to restrict the maximum power output of motorcycles to 74 kW even though evidence supporting the limit is scarce and has produced mixed results-perhaps because motorcycle performance has been measured by engine displacement, not engine power, in most of the previous studies. This study investigates the relationship of motorcycle engine power and power-to-weight ratio to risk of fatal and nonfatal crashes in Finland. The fatality rate (number of fatal accidents/number of registered motorbikes) for riders of different ages riding bikes belonging to different power and power-to-weight ratio classes was examined using a comprehensive in-depth database. Data on nonfatal accidents were acquired from a Web questionnaire (N = 2708), which also served as a basis for estimating riders' annual mileage. Mileage data allowed the calculation of accident risk per kilometer ridden for bikes differing in power and power-to-weight ratio. The fatality risk per number of registered motorcycles and per kilometer ridden increases both with power and power-to-weight ratio, independently of rider's age. No relationship between performance and risk of a less severe crash was found. The pre-accident speed of the most powerful bikes was 20 km/h or more over the speed limit in a large proportion of the fatal accidents (odds ratio = 4.8 for > 75 kW motorbikes; odds ratio = 6.2 for > 0.3 kW/kg motorbikes). The risk of being involved in a fatal crash is higher among the riders of powerful motorcycles. However, it is not clear whether the results are related to the riding habits of the riders that choose the most powerful bikes available or whether the high risk is due to the properties of the bikes themselves. Therefore, further research is needed before considering legal limits on motorcycle performance.

  10. 85 μm core rod fiber amplifier delivering 350 W/m

    DEFF Research Database (Denmark)

    Johansen, Mette Marie; Michieletto, Mattia; Kristensen, Torben

    2016-01-01

    An improved version of the distributed modal filtering (DMF) rod fiber is tested in a high power setup delivering 350 W/m of extracted signal average power limited by the available pump power. The rod fiber is thoroughly tested to record the transverse modal instability (TMI) behavior and also me...

  11. Present status and problems of nuclear power generation

    International Nuclear Information System (INIS)

    Harada, Hiroshi.

    1984-01-01

    The nuclear power generation in Japan began in 1963 with the successful power generation in the JPDR of the Japan Atomic Energy Research Institute, and since then, more than 20 years have elapsed. The Japan Atomic Power Co. started the operation of an imported Calder Hall type gas-cooled reactor with 166,000 kWe output in Tokai Nuclear Power Station in July, 1966. In 1983, the quantity of nuclear power generation was 113.1 billion kWh, which was equivalent to 21.4 % of the total power generation in Japan. As of April 1, 1984, 25 nuclear power plants with 18.28 million kW output were in operation, 12 plants of 11.8 million kW were under construction, and 7 plants of 6.05 million kW were in preparation phase. Besides, the ATR ''Fugen'' with 165,000 kW output has been in operation, and the FBR ''Monju'' with 280,000 kW output is under construction. The capacity ratio of Japanese nuclear power stations attained 71.5 % in 1983. According to the ''Long term energy demand and supply outlook'' revised in November, 1983, the nuclear power generation in 2000 will be about 62 million kW to cater for about 16 % of primary energy supply. The problems are the improvement of economy, the establishment of independent nuclear fuel cycle, the decommissioning of nuclear reactors and so on. (Kako, I.)

  12. Development of 3D models of buildings for containment of the nuclear power plant of Almaraz and of the Trillo Nuclear with the GOTHIC 8.0 code; Desarrollo de modelos 3D de los edificios de conten cion de la Central Nuclear de Almaraz y de la Central Nuclear de Trillo con el codigo GOTHIC 8.0

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez, G.; Bocanegra Melian, R.; Fernandez Cosils, K.; Barreira Pereira, P.; Rey Peinado, L.; Posada Barral, J. M.

    2014-07-01

    The objective of the first phase of the research of CNAT and the UPM project is the construction of several three-dimensional models detailed GOTHIC 8.0 code of containment of a buildings plant type PWR-W and KWU, corresponding to the Central Nuclear de Almaraz (CNA) and Trillo (CNT) respectively. (Author)

  13. Nine-channel mid-power bipolar pulse generator based on a field programmable gate array

    Energy Technology Data Exchange (ETDEWEB)

    Haylock, Ben, E-mail: benjamin.haylock2@griffithuni.edu.au; Lenzini, Francesco; Kasture, Sachin; Fisher, Paul; Lobino, Mirko [Centre for Quantum Dynamics, Griffith University, Brisbane (Australia); Queensland Micro and Nanotechnology Centre, Griffith University, Brisbane (Australia); Streed, Erik W. [Centre for Quantum Dynamics, Griffith University, Brisbane (Australia); Institute for Glycomics, Griffith University, Gold Coast (Australia)

    2016-05-15

    Many channel arbitrary pulse sequence generation is required for the electro-optic reconfiguration of optical waveguide networks in Lithium Niobate. Here we describe a scalable solution to the requirement for mid-power bipolar parallel outputs, based on pulse patterns generated by an externally clocked field programmable gate array. Positive and negative pulses can be generated at repetition rates up to 80 MHz with pulse width adjustable in increments of 1.6 ns across nine independent outputs. Each channel can provide 1.5 W of RF power and can be synchronised with the operation of other components in an optical network such as light sources and detectors through an external clock with adjustable delay.

  14. Thermal transport properties of niobium and some niobium-based alloys from 80 to 1600 K

    Energy Technology Data Exchange (ETDEWEB)

    Moore, J P; Graves, R S; Williams, R K [Oak Ridge National Lab., TN (USA)

    1980-01-01

    The electric resistivity, rho, and Seebeck coefficient, S, of 99.8 at% niobium, and Nb-4.8 at% W, Nb-5 at% Mo, Nb-10 at% Mo, and Nb-2.4 at% Mo-2.4 at% Zr alloys were measured from 80 to 1600 K, and the thermal conductivity, lambda, of the niobium and the Nb-5 at% W alloy was measured from 80 to 1300 K. A technique is described for measuring rho and S of a specimen during radial-heat-flow measurements of lambda. The transport property results, which had uncertainties of +-0.4% for rho and +-1.4% for lambda, showed the influence of tungsten and molybdenum solutes on the transport properties of niobium and were used to obtain the electronic Lorenz function of pure niobium, which was found to approach the Sommerfeld value at high temperatures.

  15. Efficiency and hardware comparison of analog control-based and digital control-based 70 W two-stage power factor corrector and DC-DC converters

    DEFF Research Database (Denmark)

    Török, Lajos; Munk-Nielsen, Stig

    2011-01-01

    A comparison of an analog and a digital controller driven 70 W two-stage power factor corrector converter is presented. Both controllers are operated in average current-mode-control for the PFC and peak current control for the DC-DC converter. Digital controller design and converter modeling...... is described. Results show that digital control can compete with the analog one in efficiency, PFC and THD....

  16. Research on industrial 10kW CO2 laser achieves major breakthrough

    Science.gov (United States)

    1991-01-01

    The industrial 10kW CO2 laser is one of the items which the industrially developed nations are competing to develop. This laser is capable of continuous output power of over 10kW and can operate continuously for more than 6 hours. The 10kW CO2 laser developed as a key task of China's 7th Five-Year Plan and all its technological targets such as output power, electrooptical conversion efficiency and primary charging continuous operating time, have reached the level of world advancement, allowing China to enter the ranks of international advancement in the area of laser technology. The industrial 10kW CO2 laser can have wide application in such areas of industry as heat treating, machining, welding and surface treatment in industries such as steel, automobiles, ship building and aircraft manufacturing. For instance, using the high-efficiency laser beams of this 10kW laser to treat rollers, fan blades and automotive cylinder blocks can increase the life of these parts and produce large economic benefits. At present, industrial tests of gear welding is already being done on this 10kW laser.

  17. 5  W output power from a double-clad hybrid fiber with Yb-doped phosphate core and silicate cladding.

    Science.gov (United States)

    Wang, Longfei; He, Dongbing; Zhang, Lei; Yu, Chunlei; Feng, Suya; Wang, Meng; Chen, Danping; Hu, Lili

    2017-08-01

    For the first time, to the best of our knowledge, we report on the realization of a laser from a Yb-doped phosphate core/silicate cladding double-clad hybrid fiber. 5 W output power was extracted with 14.6% slope efficiency and a laser spectrum of a 1027 nm central wavelength from a 20 cm long single-mode fiber with a ∼10  μm core diameter in a 20%-4% laser cavity. The laser efficiency can be significantly enhanced by correspondingly adjusting and optimizing the laser oscillator.

  18. French nuclear power plants for heat generation

    International Nuclear Information System (INIS)

    Girard, Y.

    1984-01-01

    The considerable importance that France attributes to nuclear energy is well known even though as a result of the economic crisis and the energy savings it is possible to observe a certain downward trend in the rate at which new power plants are being started up. In July 1983, a symbolic turning-point was reached - at more than 10 thousand million kW.h nuclear power accounted, for the first time, for more than 50% of the total amount of electricity generated, or approx. 80% of the total electricity output of thermal origin. On the other hand, the direct contribution - excluding the use of electricity - of nuclear energy to the heat market in France remains virtually nil. The first part of this paper discusses the prospects and realities of the application, at low and intermediate temperatures, of nuclear heat in France, while the second part describes the French nuclear projects best suited to the heat market (excluding high temperatures). (author)

  19. High efficiency class-I audio power amplifier using a single adaptive supply

    International Nuclear Information System (INIS)

    Peng Zhenfei; Yang Shanshand; Feng Yong; Hong Zhiliang; Liu Yang

    2012-01-01

    A high efficiency class-I linear audio power amplifier (PA) with an adaptive supply is presented. Its efficiency is improved by a dynamic supply to reduce the power transistors' voltage drop. A gain compression technique is adopted to make the amplifier accommodate a single positive supply. Circuit complicity and chip area are reduced because no charge pump is necessary for the negative supply. A common shared mode voltage and a symmetric layout pattern are used to minimize the non-linearity. A peak efficiency of 80% is reached at peak output power. The measured THD+N before and after the supply switching point are 0.01% and 0.05%, respectively. The maximum output power is 410 mW for an 8 Ω speaker load. Unlike switching amplifiers, the class-I amplifier operates as a linear amplifier and hence has a low EMI. The advantage of a high efficiency and low EMI makes the class-I amplifier suitable for portable and RF sensitive applications. (semiconductor integrated circuits)

  20. Powering the cars and homes of tomorrow

    Energy Technology Data Exchange (ETDEWEB)

    Ralph, T R; Hards, G A [Johnson Matthey Technology Centre, Reading (United Kingdom)

    1998-05-04

    Proton exchange membrane fuel cell (PEMFC) technology and its applications are reviewed. As a small, light power source, a PEMFC stack operates at low temperature and high power density, offers fast start-up and low pollution and is ideal for transport applications. PEMFC systems are modular and energy efficient and are being developed as portable power sources (25W-1kW) for the leisure industry and as stationary power units for the home (5-10kW), hotels and hospitals (up to 500kW). Stacks are combined in series or parallel to give the desired power output. Each stack consist of a number of single fuel cells in which the site of the power generation is a membrane electrode assembly less than a millimetre thick. Developments in reducing the cost of PEMFC stacks are described. Over the past few years, successful demonstrations have been carried out, particularly showing the potential cost-effectiveness and low pollution of PEMFC engines for buses and cars. There are aggressive plans to demonstrate PEMFC power plants for the large stationary market. (UK)

  1. Power handling of a segmented bulk W tile for JET under realistic plasma scenarios

    Science.gov (United States)

    Jet-Efda Contributors Mertens, Ph.; Coenen, J. W.; Eich, T.; Huber, A.; Jachmich, S.; Nicolai, D.; Riccardo, V.; Senik, K.; Samm, U.

    2011-08-01

    A solid tungsten divertor row has been designed for JET in the frame of the ITER-like Wall project (ILW). The plasma-facing tiles are segmented in four stacks of tungsten lamellae oriented in the toroidal direction. Earlier estimations of the expected tile performance were carried out mostly for engineering purposes, to compare the permissible heat load with the power density of 7 MW/m2 originally specified for the ILW as a uniform load for 10 s.The global thermal model developed for the W modules delivers results for more realistic plasma footprints: the poloidal extension of the outer strike point was reduced from the full lamella width of 62 mm to ⩾15 mm. Model validation is given by the experimental exposure of a 1:1 prototype stack in the ion beam facility MARION (incidence ˜6°, load E ⩽ 66 MJ/m2 on the wetted surface). Spreading the deposited energy by appropriate sweeping over one or several stacks in the torus is beneficial for the tungsten lamellae and for the support structure.

  2. 1000 Hours of Testing Completed on 10-kW Hall Thruster

    Science.gov (United States)

    Mason, Lee S.

    2001-01-01

    Between the months of April and August 2000, a 10-kW Hall effect thruster, designated T- 220, was subjected to a 1000-hr life test evaluation. Hall effect thrusters are propulsion devices that electrostatically accelerate xenon ions to produce thrust. Hall effect propulsion has been in development for many years, and low-power devices (1.35 kW) have been used in space for satellite orbit maintenance. The T-220, shown in the photo, produces sufficient thrust to enable efficient orbital transfers, saving hundreds of kilograms in propellant over conventional chemical propulsion systems. This test is the longest operation ever achieved on a high-power Hall thruster (greater than 4.5 kW) and is a key milestone leading to the use of this technology for future NASA, commercial, and military missions.

  3. Ekspansja muzeów w Europie Środkowej?

    Directory of Open Access Journals (Sweden)

    Jagodzińska, Katarzyna

    2015-06-01

    Full Text Available Przedmiotem artykułu są rozważania na temat specyfiki Europy Środkowej w zakresie kolekcji i muzeów sztuki współczesnej oraz możliwość stworzenia alternatywy regionalnej dla krajów zachodnich. Kontekstem dla tych rozważań jest ekspansjonistyczna polityka współczesnych muzeów, która w związku z licznymi nowymi inwestycjami – w szczególności Luwru, Fundacji Guggenheima, Ermitażu – budzi w świecie muzeologicznym różnorakie dylematy. Autorka omawia światowe "marki muzealne" inwestujące w Europie Środkowej, zastanawia się nad skutkami ekspansji tych "koncernów" dla kultury w regionie, wskazuje też na potencjał regionu, który można wykorzystać bez posiłkowania się nazwiskami światowych kolekcjonerów.

  4. Integracja międzypokoleniowa przedszkolaków z seniorami cz. II. Opinie rodziców dzieci w wieku przedszkolnym = Intergenerational integration between preschool children and elderly people Part II. Opinions of preschool children's parents

    Directory of Open Access Journals (Sweden)

    Agnieszka Chrzan

    2016-09-01

    4.      Zakład Medycyny Rodzinnej i Pielęgniarstwa Środowiskowego, Onkologii i Środowiskowej Opieki Zdrowotnej, Wydział Nauk o Zdrowiu, Uniwersytet Medyczny w Lublinie   Streszczenie. Cel pracy. Celem Pracy było poznanie opinii rodziców przedszkolaków na temat integracji międzypokoleniowej Metoda i materiał: Metodą badawczą był sondaż diagnostyczny z techniką ankiety. Badania przeprowadzono wśród 149 rodziców dzieci w wieku przedszkolnym z Lublina, Dęblina i Wadowic. Wyniki. Ponad 96% rodziców uważa, że dzieci powinny mieć kontakt z seniorami, natomiast 62% z nich sądzi, iż doświadczenie życiowe osób starszych jest bardzo przydatne dla młodego pokolenia. Co więcej 80,5% uznało ze organizowanie wspólnych zajęć seniorów z przedszkolakami to dobry pomysł. Niespełna 47% badanych uważało, że za czas poświęcony dzieciom, seniorzy powinni otrzymywać rekompensatę finansową z kolei 40,9% twierdziło przeciwnie.  Rodzice oczekiwaliby od osób starszych w opiece nad ich pociechami realizacji takich zajęć jak: czytanie książek czy opowiadanie zdarzeń historycznych. Korzyści ze spotkań międzypokoleniowych według rodziców to przede wszystkim wartości edukacyjne. Wnioski. Warto popularyzować idee integracji międzypokoleniowej wśród społeczeństwa ze względu na liczne korzyści, jakie może przynieść zarówno seniorom jak i młodemu pokoleniu. Słowa kluczowe. starzenie się, integracja społeczna, rozwój dziecka,   Abstract. Objective. The objective of the study was to get to know the opinions of preschool children's parents on intergenerational integration. Material and method. The diagnostic survey method was applied, together with the questionnaire technique. The survey was carried out among 149 parents of preschool children from Lublin, Dęblin and Wadowice. Results. Over 96% of the parents claim that children should have contact with seniors, while 62% of them think that the worldly experience of the

  5. Whole-house measurements of standby power consumption

    International Nuclear Information System (INIS)

    Ross, J.P.; Meier, Alan

    2000-01-01

    We investigated the variation in standby power consumption in ten California homes. Total standby power in the homes ranged from 14-169W, with an average of 67 W. This corresponded to 5 percent-26 percent of the homes' annual electricity use. The appliances with the largest standby losses were televisions, set-top boxes and printers. The large variation in the standby power of appliances providing the same service demonstrates that manufacturers are able to reduce standby losses without degrading performance. Replacing existing units with appliances with 1 W or less of standby power would reduce standby losses by 68 percent

  6. Control strategy for power management, efficiency-optimization and operating-safety of a 5-kW solid oxide fuel cell system

    International Nuclear Information System (INIS)

    Zhang, Lin; Jiang, Jianhua; Cheng, Huan; Deng, Zhonghua; Li, Xi

    2015-01-01

    Highlights: • Efficiency optimization associated with simultaneous power and thermal management. • Fast load tracing, fuel starvation, high efficiency and operating safety are considered. • Open loop pre-conditioning current strategy is proposed for load step-up transients. • Feedback control scheme is proposed for load step-up transients. - Abstract: The slow power tracking, operating safety, especially the fuel exhaustion, and high efficiency considerations are the key issues for integrated solid oxide fuel cell (SOFC) systems during power step up transients, resulting in the relatively poor dynamic capabilities and make the transient load following very challenging and must be enhanced. To this end, this paper first focus on addressing the efficiency optimization associated with simultaneous power and thermal management of a 5-kW SOFC system. Particularly, a traverse optimization process including cubic convolution interpolation algorithm are proposed to obtain optimal operating points (OOPs) with the maximum efficiency. Then this paper investigate the current implications on system step-up transient performance, then a two stage pre-conditioning current strategy and a feedback power reference control scheme is proposed for load step-up transients to balance fast load following and fuel starvation, after that safe thermal transient is validated. Simulation results show the efficacy of the control design by demonstrating the fast load following ability while maintaining the safe operation, thus safe; efficient and fast load transition can be achieved

  7. RF Power Generation in LHC

    CERN Document Server

    Brunner, O C; Valuch, D

    2003-01-01

    The counter-rotating proton beams in the Large Hadron Collider (LHC) will be captured and then accelerated to their final energies of 2 x 7 TeV by two identical 400 MHz RF systems. The RF power source required for each beam comprises eight 300 kW klystrons. The output power of each klystron is fed via a circulator and a waveguide line to the input coupler of a single-cell super-conducting (SC) cavity. Four klystrons are powered by a 100 kV, 40A AC/DC power converter, previously used for the operation of the LEP klystrons. A five-gap thyratron crowbar protects the four klystrons in each of these units. The technical specification and measured performance of the various high-power elements are discussed. These include the 400MHz/300kW klystrons with emphasis on their group delay and the three-port circulators, which have to cope with peak reflected power levels up to twice the simultaneously applied incident power of 300 kW. In addition, a novel ferrite loaded waveguide absorber, used as termination for port No...

  8. Design and development of a 6 MW peak, 24 kW average power S-band klystron

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, L.M.; Meena, Rakesh; Nangru, Subhash; Kant, Deepender; Pal, Debashis; Lamba, O.S.; Jindal, Vishnu; Jangid, Sushil Kumar, E-mail: joslm@rediffmail.com [Central Electronics Engineering Research Institute, Council of Scientific and Industrial Research, Pilani (India); Chakravarthy, D.P.; Dixit, Kavita [Bhabha Atomic Research Centre, Mumbai (India)

    2011-07-01

    A 6 MW peak, 24 kW average power S-band Klystron is under development at CEERI, Pilani under an MoU between BARC and CEERI. The design of the klystron has been completed. The electron gun has been designed using TRAK and MAGIC codes. RF cavities have been designed using HFSS and CST Microwave Studio while the complete beam wave interaction simulation has been done using MAGIC code. The thermal design of collector and RF window has been done using ANSYS code. A Gun Collector Test Module (GCTM) was developed before making actual klystron to validate gun perveance and thermal design of collector. A high voltage solid state pulsed modulator has been installed for performance valuation of the tube. The paper will cover the design aspects of the tube and experimental test results of GCTM and klystron. (author)

  9. Design and development of a 6 MW peak, 24 kW average power S-band klystron

    International Nuclear Information System (INIS)

    Joshi, L.M.; Meena, Rakesh; Nangru, Subhash; Kant, Deepender; Pal, Debashis; Lamba, O.S.; Jindal, Vishnu; Jangid, Sushil Kumar; Chakravarthy, D.P.; Dixit, Kavita

    2011-01-01

    A 6 MW peak, 24 kW average power S-band Klystron is under development at CEERI, Pilani under an MoU between BARC and CEERI. The design of the klystron has been completed. The electron gun has been designed using TRAK and MAGIC codes. RF cavities have been designed using HFSS and CST Microwave Studio while the complete beam wave interaction simulation has been done using MAGIC code. The thermal design of collector and RF window has been done using ANSYS code. A Gun Collector Test Module (GCTM) was developed before making actual klystron to validate gun perveance and thermal design of collector. A high voltage solid state pulsed modulator has been installed for performance valuation of the tube. The paper will cover the design aspects of the tube and experimental test results of GCTM and klystron. (author)

  10. Thermal analysis of a conceptual design for a 250 W(e) GPHS/FPSE space power system

    International Nuclear Information System (INIS)

    Mccomas, T.J.; Dugan, E.T.

    1991-01-01

    A thermal analysis has been performed for a 250-W(e) space nuclear power system which combines the US Department of Energy's general purpose heat source (GPHS) modules with a state-of-the-art free-piston Stirling engine (FPSE). The focus of the analysis is on the temperature of the indium fuel clad within the GPHS modules. The thermal analysis results indicate fuel clad temperatures slightly higher than the design goal temperature of 1573 K. The results are considered favorable due to numerous conservative assumptions used. To demonstrate the effects of the conservatism, a brief sensitivity analysis is performed in which a few of the key system parameters are varied to determine their effect on the fuel clad temperatures. It is shown that thermal analysis of a more detailed thermal mode should yield fuel clad temperatures below 1573 K. 3 refs

  11. Performance of two different types of anodes in membrane electrode assembly microbial fuel cells for power generation from domestic wastewater

    KAUST Repository

    Hays, Sarah

    2011-10-01

    Graphite fiber brush electrodes provide high surface areas for exoelectrogenic bacteria in microbial fuel cells (MFCs), but the cylindrical brush format limits more compact reactor designs. To enable MFC designs with closer electrode spacing, brush anodes were pressed up against a separator (placed between the electrodes) to reduce the volume occupied by the brush. Higher maximum voltages were produced using domestic wastewater (COD = 390 ± 89 mg L-1) with brush anodes (360 ± 63 mV, 1000 Ω) than woven carbon mesh anodes (200 ± 81 mV) with one or two separators. Maximum power densities were similar for brush anode reactors with one or two separators after 30 days (220 ± 1.2 and 240 ± 22 mW m-2), but with one separator the brush anode MFC power decreased to 130 ± 55 mW m-2 after 114 days. Power densities in MFCs with mesh anodes were very low (<45 mW m-2). Brush anodes MFCs had higher COD removals (80 ± 3%) than carbon mesh MFCs (58 ± 7%), but similar Coulombic efficiencies (8.6 ± 2.9% brush; 7.8 ± 7.1% mesh). These results show that compact (hemispherical) brush anodes can produce higher power and more effective domestic wastewater treatment than flat mesh anodes in MFCs. © 2011 Elsevier B.V. All rights reserved.

  12. Cesarzowa Bułgarów, augusta i bazylisa – Maria-Irena Lekapena i transfer bizantyńskiej idei kobiety-władczyni (imperial feminine w średniowiecznej Bułgarii

    Directory of Open Access Journals (Sweden)

    Zofia A. Brzozowska

    2017-10-01

    Full Text Available Empress of Bulgarians, augusta and basilissa – Maria-Irene Lekapene and the transfer of the idea of imperial feminine in the Medieval Bulgaria Maria Lekapene was a granddaughter of Byzantine Emperor Romanos I Lekapenos. In 927 she married Peter I of Bulgaria. Her marriage, ceremoniously entered into in Constantinople, aimed to strengthen the newly signed Byzantine-Bulgarian peace treaty. Historians attributed to the Empress a significant impact on the political moves of her husband. The Empress was also to introduce a lot of elements of the Byzantine theory of power in Bulgaria.   Cesarzowa Bułgarów, augusta i bazylisa – Maria-Irena Lekapena i transfer bizantyńskiej idei kobiety-władczyni (imperial feminine w średniowiecznej Bułgarii Maria Lekapena była wnuczką cesarza bizantyńskiego Romana I Lekapena. W 927 roku poślubiła władcę Bułgarii, Piotra. Jej małżeństwo, uroczyście zawarte w Konstantynopolu, miało za zadanie umocnić dopiero co podpisany pokój bizantyńsko-bułgarski. Historycy przypisywali carycy znaczny wpływ na polityczne posunięcia jej męża. Władczyni miała też zaszczepić na gruncie bułgarskim wiele elementów bizantyńskiej teorii władzy.

  13. Calculation of the power distribution in the fuel rods of the low power research reactor using the MCNP4C code

    International Nuclear Information System (INIS)

    Dawahra, S.; Khattab, K.

    2012-01-01

    The Monte Carlo method, using the MCNP4C code, was used in this paper to calculate the power distribution in 3-D geometry in the fuel rods of the Syrian Miniature Neutron Source Reactor (MNSR). To normalize the MCNP4C result to the steady state nominal thermal power, the appropriate scaling factor was defined to calculate the power distribution precisely. The maximum power of the individual rod was found in the fuel ring number 2 and was found to be 105 W. The minimum power was found in the fuel ring number 9 and was 79.9 W. The total power in the total fuel rods was 30.9 k W. This result agrees very well with nominal power reported in the reactor safety analysis report which equals 30 k W. Finally, the peak power factors, which are defined as the ratios between the maximum to the average and the maximum to the minimum powers were calculated to be 1.18 and 1.31 respectively. (author)

  14. Light extraction enhancement of 265 nm deep-ultraviolet light-emitting diodes with over 90 mW output power via an AlN hybrid nanostructure

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Shin-ichiro, E-mail: s-inoue@nict.go.jp [Advanced ICT Research Institute, National Institute of Information and Communications Technology (NICT), Kobe, Hyogo 651-2492 (Japan); Naoki, Tamari [Advanced ICT Research Institute, National Institute of Information and Communications Technology (NICT), Kobe, Hyogo 651-2492 (Japan); Tsukuba Research Laboratories, Tokuyama Corporation, Tsukuba, Ibaraki 300-4247 (Japan); Kinoshita, Toru; Obata, Toshiyuki; Yanagi, Hiroyuki [Tsukuba Research Laboratories, Tokuyama Corporation, Tsukuba, Ibaraki 300-4247 (Japan)

    2015-03-30

    Deep-ultraviolet (DUV) aluminum gallium nitride-based light-emitting diodes (LEDs) on transparent aluminum nitride (AlN) substrates with high light extraction efficiency and high power are proposed and demonstrated. The AlN bottom side surface configuration, which is composed of a hybrid structure of photonic crystals and subwavelength nanostructures, has been designed using finite-difference time-domain calculations to enhance light extraction. We have experimentally demonstrated an output power improvement of up to 196% as a result of the use of the embedded high-light-extraction hybrid nanophotonic structure. The DUV-LEDs produced have demonstrated output power as high as 90 mW in DC operation at a peak emission wavelength of 265 nm.

  15. Advantages of using a two-switch forward in single-stage power factor corrected power supplies

    DEFF Research Database (Denmark)

    Petersen, Lars

    2000-01-01

    A single-stage power factor corrected power supply using a two-switch forward is proposed to increase efficiency. The converter is operated in the DCM (discontinues conduction mode) and it is shown that this operation mode ensures the intermediate DC-bus to be controlled only by means of circuit...... supply has been implemented. The measured efficiency is between 85% and 88.5% in the range 30 W-500 W and the measured power factor at full load is 0.95....... parameters and therefore independent of load variations. The DCM operation often has a diminishing effect on the efficiency but by use of the two-switch topology high efficiency with minimum circuit complexity can be achieved in this mode. A 500 W 70 V prototype of the two-switch boost-forward PFC power...

  16. Design of the 150 kW, 46-62 MHz power amplifier for the TRIUMF KAON factory booster ring

    International Nuclear Information System (INIS)

    Kwiatkowski, S.; Enegren, T.; Poirier, R.L.

    1988-06-01

    The rf amplifiers for the KAON Factory booster ring must be capable of reactively compensating (detuning) for the injected/extracted beam load as well as providing the beam power and the cavity losses. In order to insure the stability of the rf system under heavy transient and steady state beam loading conditions it is necessary to equip the power amplifiers with fast rf feedback with sufficient gain and bandwidth to reduce the apparent Q of the rf amplifier system as seen by the beam and the other feedback loops. The maximum gain and bandwidth of such a feedback loop is limited by the propagation delay around the feedback path. To minimize the propagation delay a 2.4 kW two stage solid state driver will be used to drive the cathode of the Eimac Y567B tetrode to give an overall propagation delay less than 30 nS. The design features of the rf amplifier to meet the above conditions will be described and test results reported. (Author) (7 refs., 7 figs.)

  17. Thermo-mechanical properties of W/Mo markers coatings deposited on bulk W

    International Nuclear Information System (INIS)

    Grigore, E; Ruset, C; Gherendi, M; Chioibasu, D; Hakola, A

    2016-01-01

    In the present paper marker structures consisting of W/Mo layers were deposited on bulk W samples by using a modified CMSII method. This technology, compared to standard CMSII, prevents the formation of nano-pore structures at interfaces. The thicknesses of the markers were in the range 20–35 μm to balance the requirements associated with the wall erosion in ITER and thermo-mechanical performances. The coatings structure and composition were evaluated by glow discharge optical emission spectrometry (GDOES), and energy dispersive x-ray spectroscopy measurements (EDX). The adhesion of the coatings to the substrate has been assessed by scratch test method. In order to evaluate their effectiveness as potential markers for fusion applications, the marker coatings have been tested in an electron beam facility at a temperature of 1000 °C and a power density of about 3 MW m −2 . A number of 300 pulses with duration of 420 s (35 testing hours) were applied on the marker coated samples. (paper)

  18. Thermo-mechanical properties of W/Mo markers coatings deposited on bulk W

    Science.gov (United States)

    Grigore, E.; Ruset, C.; Gherendi, M.; Chioibasu, D.; Hakola, A.; contributors, JET

    2016-02-01

    In the present paper marker structures consisting of W/Mo layers were deposited on bulk W samples by using a modified CMSII method. This technology, compared to standard CMSII, prevents the formation of nano-pore structures at interfaces. The thicknesses of the markers were in the range 20-35 μm to balance the requirements associated with the wall erosion in ITER and thermo-mechanical performances. The coatings structure and composition were evaluated by glow discharge optical emission spectrometry (GDOES), and energy dispersive x-ray spectroscopy measurements (EDX). The adhesion of the coatings to the substrate has been assessed by scratch test method. In order to evaluate their effectiveness as potential markers for fusion applications, the marker coatings have been tested in an electron beam facility at a temperature of 1000 °C and a power density of about 3 MW m-2. A number of 300 pulses with duration of 420 s (35 testing hours) were applied on the marker coated samples.

  19. 300 W polymer electrolyte fuel cell generators for educational purposes

    Energy Technology Data Exchange (ETDEWEB)

    Tsukada, A; Buechi, F N; Scherer, G G; Haas, O [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Popelis, I [Fachhochschule Solothurn Nordwestschweiz (Switzerland)

    1999-08-01

    A 300 W fuel cell power pack has been developed for educational purposes in close collaboration with the Fachhochschule Solothurn Nordwestschweiz. The project was initiated and financed by the Swiss Federal Office of Energy. The outlay and the performance of the power pack are described. (author) 3 figs.

  20. 40 CFR 80.80 - Penalties.

    Science.gov (United States)

    2010-07-01

    ... characteristics that would have existed if the gasoline giving rise to the violations had been produced or... reformulated gasoline that is produced or imported and offered for sale and for which the requirements to... FUELS AND FUEL ADDITIVES Reformulated Gasoline § 80.80 Penalties. (a) Any person that violates any...